WorldWideScience

Sample records for sampling function obtained

  1. Effective dielectric functions of samples obtained by evaporation of alkali halides

    International Nuclear Information System (INIS)

    Sturm, J.; Grosse, P.; Theiss, W.

    1991-01-01

    This paper investigates the dielectric properties of inhomogeneous samples consisting of small alkali halide particles (NaCl, KBr) on gold-coated substrates. Our reflection measurements in the far infrared can be simulated as a thin layer of the power with an effective dielectric function on a perfectly reflecting substrate. Scanning electron micrographs provide useful information about sample topology. Several mixing formulas (e.g. the Maxwell-Garnett, the Bruggeman- and the Looyenga-formula) lead to effective dielectric functions neglecting the individual arrangement of the particles. The essence of our work is that, in contrast, the general ansatz of the Bergman spectral representation has to be employed in order to take into account topology effects on the dielectric function based on the so-called spectral density g adjustable to the specific situation. (orig.)

  2. Function of irradiated polymorphonuclear leukocytes obtained by buffy-coat centrifugation

    International Nuclear Information System (INIS)

    Wheeler, J.G.; Abramson, J.S.; Ekstrand, K.

    1984-01-01

    Several studies suggest that transfusion of polymorphonuclear leukocytes (PMNs) may be beneficial in the treatment of septic neonatal patients. Because of expense, donor availability, and the technical effort involved in obtaining PMNs by intermittent or continuous flow leukapheresis, buffy coat centrifugation of whole blood has been suggested as an alternative source. An in vitro study was performed to determine whether PMNs collected by this method have adequate oxidative and migratory function measured by chemiluminescence (CL) and chemotaxis under agarose (CT), respectively. Whole blood samples from six adult volunteers were drawn into citrate-phosphate-dextrose-adenine-one and stored at 4 degrees C for 0 to 48 hours. One-half of each sample was irradiated with 1500 rads. PMNs isolated from the buffy coat of these samples had greater than 80 percent normal CT and CL following 0 to 28 hours of storage in whole blood. Irradiation caused no depression in function. Units of whole blood yielded 1.11 +/- 0.40 X 10(9) PMNs per unit. This study indicates that transfusion of radiated PMNs obtained from stored whole blood that is less than 28 hours old is reasonable to use in studies involving PMN transfusions

  3. Hepatic mitochondrial function analysis using needle liver biopsy samples.

    Directory of Open Access Journals (Sweden)

    Michael J J Chu

    Full Text Available BACKGROUNDS AND AIM: Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cut® biopsy needle making it suitable for percutaneous application. METHODS: An 18G Bard® Max-core® biopsy instrument was used to collect samples. The optimal Tru-cut® sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry. RESULTS: The average mass of a single rat and human liver Tru-cut® biopsy was 5.60±0.30 and 5.16±0.15 mg, respectively (mean; standard error of mean. Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each showed low coefficient of variation (<10% in measurements of State-III respiration, electron transport chain (ETC capacity and respiratory control ratio (RCR. Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples. CONCLUSION: Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cut® biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function.

  4. Obtaining Samples Representative of Contaminant Distribution in an Aquifer

    International Nuclear Information System (INIS)

    Schalla, Ronald; Spane, Frank A.; Narbutovskih, Susan M.; Conley, Scott F.; Webber, William D.

    2002-01-01

    Historically, groundwater samples collected from monitoring wells have been assumed to provide average indications of contaminant concentrations within the aquifer over the well-screen interval. In-well flow circulation, heterogeneity in the surrounding aquifer, and the sampling method utilized, however, can significantly impact the representativeness of samples as contaminant indicators of actual conditions within the surrounding aquifer. This paper identifies the need and approaches essential for providing cost-effective and technically meaningful groundwater-monitoring results. Proper design of the well screen interval is critical. An accurate understanding of ambient (non-pumping) flow conditions within the monitoring well is essential for determining the contaminant distribution within the aquifer. The ambient in-well flow velocity, flow direction and volumetric flux rate are key to this understanding. Not only do the ambient flow conditions need to be identified for preferential flow zones, but also the probable changes that will be imposed under dynamic conditions that occur during groundwater sampling. Once the in-well flow conditions are understood, effective sampling can be conducted to obtain representative samples for specific depth zones or zones of interest. The question of sample representativeness has become an important issue as waste minimization techniques such as low flow purging and sampling are implemented to combat the increasing cost of well purging and sampling at many hazardous waste sites. Several technical approaches (e.g., well tracer techniques and flowmeter surveys) can be used to determine in-well flow conditions, and these are discussed with respect to both their usefulness and limitations. Proper fluid extraction methods using minimal, (low) volume and no purge sampling methods that are used to obtain representative samples of aquifer conditions are presented

  5. Approximation of the exponential integral (well function) using sampling methods

    Science.gov (United States)

    Baalousha, Husam Musa

    2015-04-01

    Exponential integral (also known as well function) is often used in hydrogeology to solve Theis and Hantush equations. Many methods have been developed to approximate the exponential integral. Most of these methods are based on numerical approximations and are valid for a certain range of the argument value. This paper presents a new approach to approximate the exponential integral. The new approach is based on sampling methods. Three different sampling methods; Latin Hypercube Sampling (LHS), Orthogonal Array (OA), and Orthogonal Array-based Latin Hypercube (OA-LH) have been used to approximate the function. Different argument values, covering a wide range, have been used. The results of sampling methods were compared with results obtained by Mathematica software, which was used as a benchmark. All three sampling methods converge to the result obtained by Mathematica, at different rates. It was found that the orthogonal array (OA) method has the fastest convergence rate compared with LHS and OA-LH. The root mean square error RMSE of OA was in the order of 1E-08. This method can be used with any argument value, and can be used to solve other integrals in hydrogeology such as the leaky aquifer integral.

  6. Perilymph sampling from the cochlear apex: a reliable method to obtain higher purity perilymph samples from scala tympani.

    Science.gov (United States)

    Salt, Alec N; Hale, Shane A; Plonkte, Stefan K R

    2006-05-15

    Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2microL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The

  7. Mars Sample Handling Functionality

    Science.gov (United States)

    Meyer, M. A.; Mattingly, R. L.

    2018-04-01

    The final leg of a Mars Sample Return campaign would be an entity that we have referred to as Mars Returned Sample Handling (MRSH.) This talk will address our current view of the functional requirements on MRSH, focused on the Sample Receiving Facility (SRF).

  8. Bespoke Bias for Obtaining Free Energy Differences within Variationally Enhanced Sampling.

    Science.gov (United States)

    McCarty, James; Valsson, Omar; Parrinello, Michele

    2016-05-10

    Obtaining efficient sampling of multiple metastable states through molecular dynamics and hence determining free energy differences is central for understanding many important phenomena. Here we present a new biasing strategy, which employs the recent variationally enhanced sampling approach (Valsson and Parrinello Phys. Rev. Lett. 2014, 113, 090601). The bias is constructed from an intuitive model of the local free energy surface describing fluctuations around metastable minima and depends on only a few parameters which are determined variationally such that efficient sampling between states is obtained. The bias constructed in this manner largely reduces the need of finding a set of collective variables that completely spans the conformational space of interest, as they only need to be a locally valid descriptor of the system about its local minimum. We introduce the method and demonstrate its power on two representative examples.

  9. Importance sampling and histogrammic representations of reactivity functions and product distributions in Monte Carlo quasiclassical trajectory calculations

    International Nuclear Information System (INIS)

    Faist, M.B.; Muckerman, J.T.; Schubert, F.E.

    1978-01-01

    The application of importance sampling as a variance reduction technique in Monte Carlo quasiclassical trajectory calculations is discussed. Two measures are proposed which quantify the quality of the importance sampling used, and indicate whether further improvements may be obtained by some other choice of importance sampling function. A general procedure for constructing standardized histogrammic representations of differential functions which integrate to the appropriate integral value obtained from a trajectory calculation is presented. Two criteria for ''optimum'' binning of these histogrammic representations of differential functions are suggested. These are (1) that each bin makes an equal contribution to the integral value, and (2) each bin has the same relative error. Numerical examples illustrating these sampling and binning concepts are provided

  10. Adaptive Importance Sampling with a Rapidly Varying Importance Function

    International Nuclear Information System (INIS)

    Booth, Thomas E.

    2000-01-01

    It is known well that zero-variance Monte Carlo solutions are possible if an exact importance function is available to bias the random walks. Monte Carlo can be used to estimate the importance function. This estimated importance function then can be used to bias a subsequent Monte Carlo calculation that estimates an even better importance function; this iterative process is called adaptive importance sampling.To obtain the importance function, one can expand the importance function in a basis such as the Legendre polynomials and make Monte Carlo estimates of the expansion coefficients. For simple problems, Legendre expansions of order 10 to 15 are able to represent the importance function well enough to reduce the error geometrically by ten orders of magnitude or more. The more complicated problems are addressed in which the importance function cannot be represented well by Legendre expansions of order 10 to 15. In particular, a problem with a cross-section notch and a problem with a discontinuous cross section are considered

  11. A self-sampling method to obtain large volumes of undiluted cervicovaginal secretions.

    Science.gov (United States)

    Boskey, Elizabeth R; Moench, Thomas R; Hees, Paul S; Cone, Richard A

    2003-02-01

    Studies of vaginal physiology and pathophysiology sometime require larger volumes of undiluted cervicovaginal secretions than can be obtained by current methods. A convenient method for self-sampling these secretions outside a clinical setting can facilitate such studies of reproductive health. The goal was to develop a vaginal self-sampling method for collecting large volumes of undiluted cervicovaginal secretions. A menstrual collection device (the Instead cup) was inserted briefly into the vagina to collect secretions that were then retrieved from the cup by centrifugation in a 50-ml conical tube. All 16 women asked to perform this procedure found it feasible and acceptable. Among 27 samples, an average of 0.5 g of secretions (range, 0.1-1.5 g) was collected. This is a rapid and convenient self-sampling method for obtaining relatively large volumes of undiluted cervicovaginal secretions. It should prove suitable for a wide range of assays, including those involving sexually transmitted diseases, microbicides, vaginal physiology, immunology, and pathophysiology.

  12. Obtaining the Bidirectional Transfer Distribution Function ofIsotropically Scattering Materials Using an Integrating Sphere

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, Jacob C.; Branden, Henrik

    2006-10-19

    This paper demonstrates a method to determine thebidirectional transfer distribution function (BTDF) using an integratingsphere. Information about the sample's angle dependent scattering isobtained by making transmittance measurements with the sample atdifferent distances from the integrating sphere. Knowledge about theilluminated area of the sample and the geometry of the sphere port incombination with the measured data combines to an system of equationsthat includes the angle dependent transmittance. The resulting system ofequations is an ill-posed problem which rarely gives a physical solution.A solvable system is obtained by using Tikhonov regularization on theill-posed problem. The solution to this system can then be used to obtainthe BTDF. Four bulk-scattering samples were characterised using both twogoniophotometers and the described method to verify the validity of thenew method. The agreement shown is great for the more diffuse samples.The solution to the low-scattering samples contains unphysicaloscillations, butstill gives the correct shape of the solution. Theorigin of the oscillations and why they are more prominent inlow-scattering samples are discussed.

  13. Improved dielectric functions in metallic films obtained via template stripping

    Science.gov (United States)

    Hyuk Park, Jong; Nagpal, Prashant; Oh, Sang-Hyun; Norris, David J.

    2012-02-01

    We compare the dielectric functions of silver interfaces obtained via thermal evaporation with those obtained with template stripping. Ellipsometry measurements show that the smoother template-stripped surfaces exhibit effective dielectric functions with a more negative real component and a smaller imaginary component, implying higher conductivity and less energy loss, respectively. These results agree with the relation between dielectric function and surface roughness derived from combining the effective-medium model and the Drude-Lorentz model. The improvement in the effective dielectric properties shows that metallic films prepared via template stripping can be favorable for applications in electronics, nanophotonics, and plasmonics.

  14. Importance sampling the Rayleigh phase function

    DEFF Research Database (Denmark)

    Frisvad, Jeppe Revall

    2011-01-01

    Rayleigh scattering is used frequently in Monte Carlo simulation of multiple scattering. The Rayleigh phase function is quite simple, and one might expect that it should be simple to importance sample it efficiently. However, there seems to be no one good way of sampling it in the literature....... This paper provides the details of several different techniques for importance sampling the Rayleigh phase function, and it includes a comparison of their performance as well as hints toward efficient implementation....

  15. Gas and liquid sampling for closed canisters in K-West basins - functional design criteria

    International Nuclear Information System (INIS)

    Pitkoff, C.C.

    1994-01-01

    The purpose of this document is to provide functions and requirements for the design and fabrication of equipment for sampling closed canisters in the K-West basin. The samples will be used to help determine the state of the fuel elements in closed canisters. The characterization information obtained will support evaluation and development of processes required for safe storage and disposition of Spent Nuclear Fuel (SNF) materials

  16. Geochemical porosity values obtained in core samples from different clay-rocks

    International Nuclear Information System (INIS)

    Fernandez, A.M.

    2010-01-01

    Document available in extended abstract form only. Argillaceous formations of low permeability are considered in many countries as potential host rocks for the disposal of high level radioactive wastes (HLRW). In order to determine their suitability for waste disposal, evaluations of the hydro-geochemistry and transport mechanisms from such geologic formations to the biosphere must be undertaken. One of the key questions about radionuclide diffusion and retention is to know the chemistry and chemical reactions and sorption processes that will occur in the rock and their effects on radionuclide mobility. In this context, the knowledge of the pore water chemistry is essential for performance assessment purposes. This information allows to establish a reliable model for the main water-rock interactions, which control the physico-chemical parameters and the chemistry of the major elements of the system. An important issue in order to model the pore water chemistry in clayey media is to determine the respective volume accessible to cations and anions, i.e, the amount of water actually available for chemical reactions/solute transport. This amount is usually referred as accessible porosity or geochemical porosity. By using the anion inventories, i.e. the anion content obtained from aqueous leaching, and assuming that all Cl - , Br - and SO4 2- leached in the aqueous extracts originates from pore water, the concentration of a conservative ion can be converted into the real pore water concentration if the accessible porosity is known. In this work, the accessible porosity or geochemical porosity has been determined in core samples belonging to four different formations: Boom Clay from Hades URL (Belgium, BE), Opalinus Clay from Mont Terri (Switzerland, CH), and Callovo-Oxfordian argillite from Bure URL (France, FR). The geochemical or chloride porosity was defined as the ratio between the pore water volume containing Cl-bearing pore water and the total volume of a sample

  17. Method for estimating modulation transfer function from sample images.

    Science.gov (United States)

    Saiga, Rino; Takeuchi, Akihisa; Uesugi, Kentaro; Terada, Yasuko; Suzuki, Yoshio; Mizutani, Ryuta

    2018-02-01

    The modulation transfer function (MTF) represents the frequency domain response of imaging modalities. Here, we report a method for estimating the MTF from sample images. Test images were generated from a number of images, including those taken with an electron microscope and with an observation satellite. These original images were convolved with point spread functions (PSFs) including those of circular apertures. The resultant test images were subjected to a Fourier transformation. The logarithm of the squared norm of the Fourier transform was plotted against the squared distance from the origin. Linear correlations were observed in the logarithmic plots, indicating that the PSF of the test images can be approximated with a Gaussian. The MTF was then calculated from the Gaussian-approximated PSF. The obtained MTF closely coincided with the MTF predicted from the original PSF. The MTF of an x-ray microtomographic section of a fly brain was also estimated with this method. The obtained MTF showed good agreement with the MTF determined from an edge profile of an aluminum test object. We suggest that this approach is an alternative way of estimating the MTF, independently of the image type. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Closed-Form Representations of the Density Function and Integer Moments of the Sample Correlation Coefficient

    Directory of Open Access Journals (Sweden)

    Serge B. Provost

    2015-07-01

    Full Text Available This paper provides a simplified representation of the exact density function of R, the sample correlation coefficient. The odd and even moments of R are also obtained in closed forms. Being expressed in terms of generalized hypergeometric functions, the resulting representations are readily computable. Some numerical examples corroborate the validity of the results derived herein.

  19. Development of functional spaghetti enriched in bioactive compounds using barley coarse fraction obtained by air classification.

    Science.gov (United States)

    Verardo, Vito; Gómez-Caravaca, Ana Maria; Messia, Maria Cristina; Marconi, Emanuele; Caboni, Maria Fiorenza

    2011-09-14

    Barley byproducts obtained by air classification have been used to produce a different barley functional spaghetti, which were compared to different commercial whole semolina samples. Total, insoluble, and soluble fiber and β-glucan contents of the barley spaghetti were found to be greater than those of commercial samples. Furthermore, it was proved that barley spaghetti reached the FDA requirements, which could allow these pastas to deserve the health claims "good source of dietary fiber" and "may reduce the risk of heart disease". When the barley coarse fraction was used, a flavan-3-ols enrichment and an increase of antioxidant activity were reported, while commercial samples showed the absence of flavan-3-ols and a higher presence of phenolic acids and tannins. Whole semolina commercial spaghetti had a significantly higher content of phenolic acids than semolina spaghetti samples. Besides, it was observed that when vital gluten was added to the spaghetti formulation, phenolic compounds were blocked in the gluten network and were partially released during the cooking process.

  20. A method for ion distribution function evaluation using escaping neutral atom kinetic energy samples

    International Nuclear Information System (INIS)

    Goncharov, P.R.; Ozaki, T.; Veshchev, E.A.; Sudo, S.

    2008-01-01

    A reliable method to evaluate the probability density function for escaping atom kinetic energies is required for the analysis of neutral particle diagnostic data used to study the fast ion distribution function in fusion plasmas. Digital processing of solid state detector signals is proposed in this paper as an improvement of the simple histogram approach. Probability density function for kinetic energies of neutral particles escaping from the plasma has been derived in a general form taking into account the plasma ion energy distribution, electron capture and loss rates, superposition along the diagnostic sight line and the magnetic surface geometry. A pseudorandom number generator has been realized that enables a sample of escaping neutral particle energies to be simulated for given plasma parameters and experimental conditions. Empirical probability density estimation code has been developed and tested to reconstruct the probability density function from simulated samples assuming. Maxwellian and classical slowing down plasma ion energy distribution shapes for different temperatures and different slowing down times. The application of the developed probability density estimation code to the analysis of experimental data obtained by the novel Angular-Resolved Multi-Sightline Neutral Particle Analyzer has been studied to obtain the suprathermal particle distributions. The optimum bandwidth parameter selection algorithm has also been realized. (author)

  1. Difficulties in obtaining representative samples for compliance with the Ballast Water Management Convention

    Digital Repository Service at National Institute of Oceanography (India)

    Carney, K.J; Basurko, O.C; Pazouki, K.; Marsham, S.; Delany, J; Desai, D.V.; Anil, A.C; Mesbahi, E.

    water, the shape, size and number of ballast tanks and the heterogeneous distribution of organisms within tanks. These factors hinder efforts to obtain samples that truly represent the total ballast water onboard a vessel. A known cell density...

  2. Effects of physical and chemical heterogeneity on water-quality samples obtained from wells

    Science.gov (United States)

    Reilly, Thomas E.; Gibs, Jacob

    1993-01-01

    Factors that affect the mass of chemical constituents entering a well include the distributions of flow rate and chemical concentrations along and near the screened or open section of the well. Assuming a layered porous medium (with each layer being characterized by a uniform hydraulic conductivity and chemical concentration), a knowledge of the flow from each layer along the screened zone and of the chemical concentrations in each layer enables the total mass entering the well to be determined. Analyses of hypothetical systems and a site at Galloway, NJ, provide insight into the temporal variation of water-quality data observed when withdrawing water from screened wells in heterogeneous ground-water systems.The analyses of hypothetical systems quantitatively indicate the cause-and-effect relations that cause temporal variability in water samples obtained from wells. Chemical constituents that have relatively uniform concentrations with depth may not show variations in concentrations in the water discharged from a well after the well is purged (evacuation of standing water in the well casing). However, chemical constituents that do not have uniform concentrations near the screened interval of the well may show variations in concentrations in the well discharge water after purging because of the physics of ground-water flow in the vicinity of the screen.Water-quality samples were obtained through time over a 30 minute period from a site at Galloway, NJ. The water samples were analyzed for aromatic hydrocarbons, and the data for benzene, toluene, and meta+para xylene were evaluated for temporal variations. Samples were taken from seven discrete zones, and the flow-weighted concentrations of benzene, toluene, and meta+para xylene all indicate an increase in concentration over time during pumping. These observed trends in time were reproduced numerically based on the estimated concentration distribution in the aquifer and the flow rates from each zone.The results of

  3. Method for utilizing properties of the sinc(x) function for phase retrieval on nyquist-under-sampled data

    Science.gov (United States)

    Dean, Bruce H. (Inventor); Smith, Jeffrey Scott (Inventor); Aronstein, David L. (Inventor)

    2012-01-01

    Disclosed herein are systems, methods, and non-transitory computer-readable storage media for simulating propagation of an electromagnetic field, performing phase retrieval, or sampling a band-limited function. A system practicing the method generates transformed data using a discrete Fourier transform which samples a band-limited function f(x) without interpolating or modifying received data associated with the function f(x), wherein an interval between repeated copies in a periodic extension of the function f(x) obtained from the discrete Fourier transform is associated with a sampling ratio Q, defined as a ratio of a sampling frequency to a band-limited frequency, and wherein Q is assigned a value between 1 and 2 such that substantially no aliasing occurs in the transformed data, and retrieves a phase in the received data based on the transformed data, wherein the phase is used as feedback to an optical system.

  4. Prospects of obtaining samples of bottom sediments from subglacial lake Vostok

    Directory of Open Access Journals (Sweden)

    Н. И. Васильев

    2017-04-01

    Full Text Available The paper proves the timeliness of obtaining and examining bottom sediments from subglacial Lake Vostok. Predictive geological section of Lake Vostok and information value of bottom sediments have been examined. Severe requirements towards environmental security of lake examinations and sampling of bottom sediments rule out the use of conventional drilling technologies, as they would pollute the lake with injection liquid from the borehole. In order to carry out sampling of bottom sediments from the subglacial lake, it is proposed to use a dynamically balanced tool string, which enables rotary drilling without any external support on borehole walls to transmit counter torque.     A theoretical analysis has been carried out to assess the operation of the tool string, which is a two-mass oscillatory electromechanical system of reciprocating and rotating motion (RRM with two degrees of freedom.

  5. Accuracy of three-body wave functions obtained with the correlation-function hyperspherical-harmonic method

    International Nuclear Information System (INIS)

    Haftel, M.I.; Mandelzweig, V.B.

    1990-01-01

    The local convergence and accuracy of wave functions obtained by direct solution of the Schroedinger equation with the help of the correlation-function hyperspherical-harmonic method are analyzed for ground and excited states of the helium atom and for the ground state of the positronium negative ion. The inclusion of the cusp conditions into the correlation function is shown to be of crucial importance, not only near the coalescence points, but also away from them. The proper inclusion of all cusps yields for the ground state of the helium atom the local wave-function accuracy of about 10 -7 for different interparticle distances. The omission of one of the cusps in the excited helium atom reduces the wave-function precision to 10 -2 near the corresponding coalescence point and to 10 -4 --10 -5 away from it

  6. Statistical evaluation of the data obtained from the K East Basin Sandfilter Backwash Pit samples

    International Nuclear Information System (INIS)

    Welsh, T.L.

    1994-01-01

    Samples were obtained from different locations from the K Each Sandfilter Backwash Pit to characterize the sludge material. These samples were analyzed chemically for elements, radionuclides, and residual compounds. The analytical results were statistically analyzed to determine the mean analyte content and the associated variability for each mean value

  7. Study of anti corrosive behaviour on A I 6061 samples covered with Ni-P alloys obtained by autocatalytic method

    International Nuclear Information System (INIS)

    Castro, M. E; Barbero, J. A; Bubach, E

    2006-01-01

    There are many ways to keep safe an industrial material from corrosion attack.One is covering the piece with a layer of another material which corrosion resistance is higher to the one of the element to protect.The anticorrosion protection mechanism is achieved by the formation of a physical pore less barrier without any defects.This avoid the arrival of those agents from environment responsible of electrochemical attack.In this paper, corrosion resistance of metallic coatings over nuclear usage aluminum samples is analyzed.Our interest is aimed on nickel I phosphorous alloy coatings (Ni I P) obtained by electroless method (autocatalytic) over Al 6061 alloy samples.A comparative study is carried on with different phosphorous contents but always under 12 %.This job is completed with other nickel coating, Vitro vac 0080 (with no phosphorous content) in order to compare structures and anti corrosive properties.Besides, the comparison between mentioned materials and aluminum samples is made.The study is carried on using superficial characterization of each sample with or without coating through a series of complementary techniques such as chemical, electrochemical (linear sweep voltammetry, cyclic voltammetry, polarization resistance determination) and physical (scanning electronic microscopy, hardness determination) techniques.Finally, variable correlation is made as a function of the phosphorous content in the samples used in the experiences.The coating structure obtained is amorphous.It presents no pore or failure and its hardness shows important values.The electrochemical analysis allows to check that anti corrosive protection capacity of Ni-P alloy increases with the phosphorous content in the coat. Al 6061 by itself demonstrate an electrochemically bad behaviour.Substrate I coating adherence is very good [es

  8. Magnetic properties of ultrafine-grained cobalt samples obtained from consolidated nanopowders

    Energy Technology Data Exchange (ETDEWEB)

    Fellah, F.; Cherif, S.M.; Schoenstein, F.; Jouini, N.; Dirras, G. [LSPM (CNRS-UPR 3407), Universite Paris 13, 99 av. J.B. Clement, 93430 Villetaneuse (France); Bouziane, K. [Department of Physics, College of Science, Sultan Qaboos University, P.O. Box 36, Al-Khodh 123 (Oman)

    2011-08-15

    Co powders having nominal average particle size of 50 and 240 nm were synthesized using a polyol method and then consolidated by hot isostatic pressing (HIP) or the emerging spark plasma sintering (SPS) compaction processes. Bulk polycrystalline aggregates were obtained, having average grain sizes of about 200 and 300 nm, respectively. It is found that both nanoparticles and consolidated samples exhibit a soft ferromagnetic behavior. The magnetization reversal likely occurs by nucleation/propagation process. However, a curling process can be involved in the magnetization reversal for the smaller particles. The dynamic measurements provide for the consolidated samples magnetic parameters corresponding to bulk cobalt with vanishing anisotropy. The contribution of the intergranular region is found to be negligible. We can infer that the used consolidation routes insure a good magnetic interfacial contact between the particles. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. Dynamic Contrast-Enhanced Perfusion MRI of High Grade Brain Gliomas Obtained with Arterial or Venous Waveform Input Function.

    Science.gov (United States)

    Filice, Silvano; Crisi, Girolamo

    2016-01-01

    The aim of this study was to evaluate the differences in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) perfusion estimates of high-grade brain gliomas (HGG) due to the use of an input function (IF) obtained respectively from arterial (AIF) and venous (VIF) approaches by two different commercially available software applications. This prospective study includes 20 patients with pathologically confirmed diagnosis of high-grade gliomas. The data source was processed by using two DCE dedicated commercial packages, both based on the extended Toft model, but the first customized to obtain input function from arterial measurement and the second from sagittal sinus sampling. The quantitative parametric perfusion maps estimated from the two software packages were compared by means of a region of interest (ROI) analysis. The resulting input functions from venous and arterial data were also compared. No significant difference has been found between the perfusion parameters obtained with the two different software packages (P-value < .05). The comparison of the VIFs and AIFs obtained by the two packages showed no statistical differences. Direct comparison of DCE-MRI measurements with IF generated by means of arterial or venous waveform led to no statistical difference in quantitative metrics for evaluating HGG. However, additional research involving DCE-MRI acquisition protocols and post-processing would be beneficial to further substantiate the effectiveness of venous approach as the IF method compared with arterial-based IF measurement. Copyright © 2015 by the American Society of Neuroimaging.

  10. Data analysis of a polycrystalline nickel sample obtained with neutron diffraction

    International Nuclear Information System (INIS)

    Parente, C.B.R.; Mazzochi, V.L.; Araujo Kaschny, J.R. de; Costa, M.S. da; Rizzo, P.; Campos, W.M.S.

    1990-01-01

    A simple analysis of the nickel structure was made. Neutron diffraction data were used, obtained with polycrystalline nickel placed in a cylindrical sample-holder with dimensions of 1,5cm of diameter and 5cm of height. The theoretical intensities were calculated of 3 forms: 1. without considering the temperature and obsorption effects, 2. considering only the temperature effect and 3. considering both the temperature and absorption effects. The disagreement factors found in this 3 cases were, respectively, R 1 = 13.4%, R 2 = 7,7% e R 3 = 7,5%. (L.C.)

  11. Recent researches concerning the obtaining of functional textiles based on conductive yarns

    Science.gov (United States)

    Leon, A. L.; Manea, L. R.; Hristian, L.

    2016-08-01

    Modem textile industry is influenced both by consumers' lifestyle and by novel materials. Functional textiles can be included into the group of technical textiles. The functional activity can be shortly interpreted as "sense - react - adapt" to the environment while traditional materials meet only passive protective role, a barrier between body and environment. Functional materials cross the conventional limits because they are designed for specific performances, being part of domains as: telemedicine, medicine, aeronautics, biotechnology, nanotechnology, protective clothes, sportswear, etc. This paper highlights the most recent developments in the field of using conductive yarns for obtaining functional textiles. Conductive fabrics can be done by incorporating into the textile structure the conductive fibers / yarns. The technologies differ from embroidering, sewing, weaving, knitting to braiding and obtaining nonwovens. The conductive fabrics production has a quickly growth because it is a high demand for these textiles used for data transfer in clothing, monitoring vital signs, germ-free garments, brain-computer interface, etc. Nowadays it is of high interest surface treatments of fibers/yarns which can be considered as a novel kind of textile finishing. There are presented some researches related to obtaining conductive yarns by coating PET and PP yarns with PANi conductive polymer.

  12. Evaluation of endoscopically obtained duodenal biopsy samples from cats and dogs in an adapter-modified Ussing chamber

    Science.gov (United States)

    DeBiasio, John V.; Suchodolski, Jan S.; Newman, Shelley; Musch, Mark W.; Steiner, Jörg M.

    2014-01-01

    This study was conducted to evaluate an adapter-modified Ussing chamber for assessment of transport physiology in endoscopically obtained duodenal biopsies from healthy cats and dogs, as well as dogs with chronic enteropathies. 17 duodenal biopsies from five cats and 51 duodenal biopsies from 13 dogs were obtained. Samples were transferred into an adapter-modified Ussing chamber and sequentially exposed to various absorbagogues and secretagogues. Overall, 78.6% of duodenal samples obtained from cats responded to at least one compound. In duodenal biopsies obtained from dogs, the rate of overall response ranged from 87.5% (healthy individuals; n = 8), to 63.6% (animals exhibiting clinical signs of gastrointestinal disease and histopathological unremarkable duodenum; n = 15), and 32.1% (animals exhibiting clinical signs of gastrointestinal diseases and moderate to severe histopathological lesions; n = 28). Detailed information regarding the magnitude and duration of the response are provided. The adapter-modified Ussing chamber enables investigation of the absorptive and secretory capacity of endoscopically obtained duodenal biopsies from cats and dogs and has the potential to become a valuable research tool. The response of samples was correlated with histopathological findings. PMID:24378587

  13. Screening disrupted molecular functions and pathways associated with clear cell renal cell carcinoma using Gibbs sampling.

    Science.gov (United States)

    Nan, Ning; Chen, Qi; Wang, Yu; Zhai, Xu; Yang, Chuan-Ce; Cao, Bin; Chong, Tie

    2017-10-01

    To explore the disturbed molecular functions and pathways in clear cell renal cell carcinoma (ccRCC) using Gibbs sampling. Gene expression data of ccRCC samples and adjacent non-tumor renal tissues were recruited from public available database. Then, molecular functions of expression changed genes in ccRCC were classed to Gene Ontology (GO) project, and these molecular functions were converted into Markov chains. Markov chain Monte Carlo (MCMC) algorithm was implemented to perform posterior inference and identify probability distributions of molecular functions in Gibbs sampling. Differentially expressed molecular functions were selected under posterior value more than 0.95, and genes with the appeared times in differentially expressed molecular functions ≥5 were defined as pivotal genes. Functional analysis was employed to explore the pathways of pivotal genes and their strongly co-regulated genes. In this work, we obtained 396 molecular functions, and 13 of them were differentially expressed. Oxidoreductase activity showed the highest posterior value. Gene composition analysis identified 79 pivotal genes, and survival analysis indicated that these pivotal genes could be used as a strong independent predictor of poor prognosis in patients with ccRCC. Pathway analysis identified one pivotal pathway - oxidative phosphorylation. We identified the differentially expressed molecular functions and pivotal pathway in ccRCC using Gibbs sampling. The results could be considered as potential signatures for early detection and therapy of ccRCC. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. A new way of obtaining analytic approximations of Chandrasekhar's H function

    International Nuclear Information System (INIS)

    Vukanic, J.; Arsenovic, D.; Davidovic, D.

    2007-01-01

    Applying the mean value theorem for definite integrals in the non-linear integral equation for Chandrasekhar's H function describing conservative isotropic scattering, we have derived a new, simple analytic approximation for it, with a maximal relative error below 2.5%. With this new function as a starting-point, after a single iteration in the corresponding integral equation, we have obtained a new, highly accurate analytic approximation for the H function. As its maximal relative error is below 0.07%, it significantly surpasses the accuracy of other analytic approximations

  15. Characterization of specimens obtained by different sampling methods for evaluation of periodontal bacteria.

    Science.gov (United States)

    Okada, Ayako; Sogabe, Kaoru; Takeuchi, Hiroaki; Okamoto, Masaaki; Nomura, Yoshiaki; Hanada, Nobuhiro

    2017-12-27

    Quantitative analysis of periodontal bacteria is considered useful for clinical diagnosis, evaluation and assessment of the risk of periodontal disease. The purpose of this study was to compare the effectiveness of sampling of saliva, supragingival and subgingival plaque for evaluation of periodontal bacteria. From each of 12 subjects, i) subgingival plaque was collected from the deepest pocket using a sterile paper point, ii) stimulated whole saliva was collected after chewing gum, and iii) supragingival plaque was collected using a tooth brush. These samples were sent to the medical examination laboratory for quantitative analysis of the counts of three periodontal bacterial species: Porphyromonas gingivalis, Treponema denticola, and Tannerella forsythia. The proportions of these bacteria in subgingival plaque were higher than those in saliva or supragingival plaque, but lower in subgingival plaque than in saliva or supragingival plaque. In several cases, periodontal bacteria were below the levels of detection in subgingival plaque. We concluded that samples taken from subgingival plaque may be more useful for evaluating the proportion of periodontal bacteria in deep pockets than is the case for other samples. Therefore, for evaluation of periodontal bacteria, clinicians should consider the characteristics of the specimens obtained using different sampling methods.

  16. Physical, mental, and cognitive function in a convenience sample of centenarians in Australia.

    Science.gov (United States)

    Richmond, Robyn L; Law, Jenaleen; Kay-Lambkin, Frances

    2011-06-01

    To examine the physical, mental, and cognitive function of centenarians. Descriptive study using a structured questionnaire and convenience sampling. Residential care facilities and private dwellings in Australia. A convenience sample of 188 centenarians. The Hospital Anxiety and Depression Scale (HADS) screened for anxiety and depression. The Katz Index of Independence in Activities of Daily Living (Katz ADL) was used to assess functional status. The Quality of Life Scale was used to assess quality of life. The Mini-Mental State Examination (MMSE) was used to screen for dementia. Structured responses were obtained for living arrangement, marital status, social relationships, and supports. Centenarians had regular contact with friends (59%), neighbors (62%), and families (72%); 54% were religious and 43.5% had received social supports. Average MMSE and Katz ADL scores were 21.5 and 3.7, respectively; 45% had scores on the MMSE indicative of dementia, 10% indicated anxiety and 14% depression on the HADS. Participants with poor ratings of health experienced higher rates of anxiety and depression than their healthier counterparts. In this convenience sample of Australian centenarians, anxiety and depression was relatively nonexistent, and most reported a high quality of life. This was despite objective deterioration in functional status, paralleling the aging process, and high dependence on others for everyday tasks. Potentially, this is suggestive of a unique ability within the sample to adapt to aging and its limitations. © 2011, Copyright the Authors. Journal compilation © 2011, The American Geriatrics Society.

  17. Taxonomic and functional profiles of soil samples from Atlantic forest and Caatinga biomes in northeastern Brazil.

    Science.gov (United States)

    Pacchioni, Ralfo G; Carvalho, Fabíola M; Thompson, Claudia E; Faustino, André L F; Nicolini, Fernanda; Pereira, Tatiana S; Silva, Rita C B; Cantão, Mauricio E; Gerber, Alexandra; Vasconcelos, Ana T R; Agnez-Lima, Lucymara F

    2014-06-01

    Although microorganisms play crucial roles in ecosystems, metagenomic analyses of soil samples are quite scarce, especially in the Southern Hemisphere. In this work, the microbial diversity of soil samples from an Atlantic Forest and Caatinga was analyzed using a metagenomic approach. Proteobacteria and Actinobacteria were the dominant phyla in both samples. Among which, a significant proportion of stress-resistant bacteria associated to organic matter degradation was found. Sequences related to metabolism of amino acids, nitrogen, and DNA and stress resistance were more frequent in Caatinga soil, while the forest sample showed the highest occurrence of hits annotated in phosphorous metabolism, defense mechanisms, and aromatic compound degradation subsystems. The principal component analysis (PCA) showed that our samples are close to the desert metagenomes in relation to taxonomy, but are more similar to rhizosphere microbiota in relation to the functional profiles. The data indicate that soil characteristics affect the taxonomic and functional distribution; these characteristics include low nutrient content, high drainage (both are sandy soils), vegetation, and exposure to stress. In both samples, a rapid turnover of organic matter with low greenhouse gas emission was suggested by the functional profiles obtained, reinforcing the importance of preserving natural areas. © 2014 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.

  18. Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument

    Science.gov (United States)

    Chipera, S. J.; Vaniman, D. T.; Bish, D. L.; Sarrazin, P.; Feldman, S.; Blake, D. F.; Bearman, G.; Bar-Cohen, Y.

    2004-01-01

    A miniature XRD/XRF (X-ray diffraction / X-ray fluorescence) instrument, CHEMIN, is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed to enable remote XRD analysis is how best to obtain a representative sample powder for analysis. For powder XRD analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a two-dimensional detector as used in the CHEMIN instrument will produce good results even with poorly prepared powder, the quality of the data will improve and the time required for data collection will be reduced if the sample is fine-grained and randomly oriented. A variety of methods have been proposed for XRD sample preparation. Chipera et al. presented grain size distributions and XRD results from powders generated with an Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL. The USDC was shown to be an effective instrument for sampling rock to produce powder suitable for XRD. In this paper, we compare powder prepared using the USDC with powder obtained with a miniaturized rock crusher developed at JPL and with powder obtained with a rotary tungsten carbide bit to powders obtained from a laboratory bench-scale Retsch mill (provides benchmark mineralogical data). These comparisons will allow assessment of the suitability of these methods for analysis by an XRD/XRF instrument such as CHEMIN.

  19. Detection and genotyping of human papillomavirus in self-obtained cervicovaginal samples by using the FTA cartridge: new possibilities for cervical cancer screening.

    Science.gov (United States)

    Lenselink, Charlotte H; de Bie, Roosmarie P; van Hamont, Dennis; Bakkers, Judith M J E; Quint, Wim G V; Massuger, Leon F A G; Bekkers, Ruud L M; Melchers, Willem J G

    2009-08-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF(10)-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening.

  20. Image-derived input function obtained in a 3TMR-brainPET

    Energy Technology Data Exchange (ETDEWEB)

    Silva, N.A. da [Institute of Biophysics and Biomedical Engineering, University of Lisbon (Portugal); Institute of Neurosciences and Medicine - 4, Juelich (Germany); Herzog, H., E-mail: h.herzog@fz-juelich.de [Institute of Neurosciences and Medicine - 4, Juelich (Germany); Weirich, C.; Tellmann, L.; Rota Kops, E. [Institute of Neurosciences and Medicine - 4, Juelich (Germany); Hautzel, H. [Department of Nuclear Medicine (KME), University of Duesseldorf, Medical Faculty at Research Center Juelich, Juelich (Germany); Almeida, P. [Institute of Biophysics and Biomedical Engineering, University of Lisbon (Portugal)

    2013-02-21

    Aim: The combination of a high-resolution MR-compatible BrainPET insert operated within a 3 T MAGNETOM Trio MR scanner is an excellent tool for obtaining an image derived input function (IDIF), due to simultaneous imaging. In this work, we explore the possibility of obtaining an IDIF from volumes of interest (VOI) defined over the carotid arteries (CAs) using the MR data. Material and methods: FDG data from three patients without brain disorders were included. VOIs were drawn bilaterally over the CAs on a MPRAGE image using a 50% isocontour (MR50VOI). CA PET/MR co-registration was examined based on an individual and combined CA co-registration. After that, to estimate the IDIF, the MR50VOI average (IDIF-A), four hottest pixels per plane (IDIF-4H) and four hottest pixels in VOI (IDIF-4V) were considered. A model-based correction for residual partial volume effects involving venous blood samples was applied, from which partial volume (PV) and spillover (SP) coefficients were estimated. Additionally, a theoretical PV coefficient (PVt) was calculated based on MR50VOI. Results: The results show an excellent co-registration between the MR and PET, with an area under the curve ratio between both co-registration methods of 1.00±0.04. A good agreement between PV and PVt was found for IDIF-A, with PV of 0.39±0.06 and PVt 0.40±0.03, and for IDIF-4H, with PV of 0.47±0.05 and PVt 0.47±0.03. The SPs were 0.20±0.03 and 0.21±0.03 for IDIF-A and IDIF-4H, respectively. Conclusion: The integration of a high resolution BrainPET in an MR scanner allows to obtain an IDIF from an MR-based VOI. This must be corrected for a residual partial volume effect.

  1. A simple method for measurement of cerebral blood flow using 123I-IMP SPECT with calibrated standard input function by one point blood sampling. Validation of calibration by one point venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Akaizawa, Takashi; Goto, Ryoui

    1994-01-01

    In a simplified method for measurement of cerebral blood flow using one 123 I-IMP SPECT scan and one point arterial blood sampling (Autoradiography method), input function is obtained by calibrating a standard input function by one point arterial blood sampling. A purpose of this study is validation of calibration by one point venous blood sampling as a substitute for one point arterial blood sampling. After intravenous infusion of 123 I-IMP, frequent arterial and venous blood sampling were simultaneously performed on 12 patients of CNS disease without any heart and lung disease and 5 normal volunteers. The radioactivity ratio of venous whole blood which obtained from cutaneous cubital vein to arterial whole blood were 0.76±0.08, 0.80±0.05, 0.81±0.06, 0.83±0.11 at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivities were always 20% lower than those of arterial blood radioactivity during 50 min. However, the ratio which obtained from cutaneous dorsal hand vein to artery were 0.93±0.02, 0.94±0.05, 0.98±0.04, 0.98±0.03, at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivity was consistent with artery. These indicate that arterio-venous difference of radioactivity in a peripheral cutaneous vein like a dorsal hand vein is minimal due to arteriovenous shunt in palm. Therefore, a substitution by blood sampling from cutaneous dorsal hand vein for artery will be possible. Optimized time for venous blood sampling evaluated by error analysis was 20 min after 123 I-IMP infusion, which is 10 min later than that of arterial blood sampling. (author)

  2. Hybrid image and blood sampling input function for quantification of small animal dynamic PET data

    International Nuclear Information System (INIS)

    Shoghi, Kooresh I.; Welch, Michael J.

    2007-01-01

    We describe and validate a hybrid image and blood sampling (HIBS) method to derive the input function for quantification of microPET mice data. The HIBS algorithm derives the peak of the input function from the image, which is corrected for recovery, while the tail is derived from 5 to 6 optimally placed blood sampling points. A Bezier interpolation algorithm is used to link the rightmost image peak data point to the leftmost blood sampling point. To assess the performance of HIBS, 4 mice underwent 60-min microPET imaging sessions following a 0.40-0.50-mCi bolus administration of 18 FDG. In total, 21 blood samples (blood-sampled plasma time-activity curve, bsPTAC) were obtained throughout the imaging session to compare against the proposed HIBS method. MicroPET images were reconstructed using filtered back projection with a zoom of 2.75 on the heart. Volumetric regions of interest (ROIs) were composed by drawing circular ROIs 3 pixels in diameter on 3-4 transverse planes of the left ventricle. Performance was characterized by kinetic simulations in terms of bias in parameter estimates when bsPTAC and HIBS are used as input functions. The peak of the bsPTAC curve was distorted in comparison to the HIBS-derived curve due to temporal limitations and delay in blood sampling, which affected the rates of bidirectional exchange between plasma and tissue. The results highlight limitations in using bsPTAC. The HIBS method, however, yields consistent results, and thus, is a substitute for bsPTAC

  3. Data Transformation Functions for Expanded Search Spaces in Geographic Sample Supervised Segment Generation

    Directory of Open Access Journals (Sweden)

    Christoff Fourie

    2014-04-01

    Full Text Available Sample supervised image analysis, in particular sample supervised segment generation, shows promise as a methodological avenue applicable within Geographic Object-Based Image Analysis (GEOBIA. Segmentation is acknowledged as a constituent component within typically expansive image analysis processes. A general extension to the basic formulation of an empirical discrepancy measure directed segmentation algorithm parameter tuning approach is proposed. An expanded search landscape is defined, consisting not only of the segmentation algorithm parameters, but also of low-level, parameterized image processing functions. Such higher dimensional search landscapes potentially allow for achieving better segmentation accuracies. The proposed method is tested with a range of low-level image transformation functions and two segmentation algorithms. The general effectiveness of such an approach is demonstrated compared to a variant only optimising segmentation algorithm parameters. Further, it is shown that the resultant search landscapes obtained from combining mid- and low-level image processing parameter domains, in our problem contexts, are sufficiently complex to warrant the use of population based stochastic search methods. Interdependencies of these two parameter domains are also demonstrated, necessitating simultaneous optimization.

  4. Detection and Genotyping of Human Papillomavirus in Self-Obtained Cervicovaginal Samples by Using the FTA Cartridge: New Possibilities for Cervical Cancer Screening ▿

    Science.gov (United States)

    Lenselink, Charlotte H.; de Bie, Roosmarie P.; van Hamont, Dennis; Bakkers, Judith M. J. E.; Quint, Wim G. V.; Massuger, Leon F. A. G.; Bekkers, Ruud L. M.; Melchers, Willem J. G.

    2009-01-01

    This study assesses human papillomavirus (HPV) detection and genotyping in self-sampled genital smears applied to an indicating FTA elute cartridge (FTA cartridge). The study group consisted of 96 women, divided into two sample sets. All samples were analyzed by the HPV SPF10-Line Blot 25. Set 1 consisted of 45 women attending the gynecologist; all obtained a self-sampled cervicovaginal smear, which was applied to an FTA cartridge. HPV results were compared to a cervical smear (liquid based) taken by a trained physician. Set 2 consisted of 51 women who obtained a self-sampled cervicovaginal smear at home, which was applied to an FTA cartridge and to a liquid-based medium. DNA was obtained from the FTA cartridges by simple elution as well as extraction. Of all self-obtained samples of set 1, 62.2% tested HPV positive. The overall agreement between self- and physician-obtained samples was 93.3%, in favor of the self-obtained samples. In sample set 2, 25.5% tested HPV positive. The overall agreement for high-risk HPV presence between the FTA cartridge and liquid-based medium and between DNA elution and extraction was 100%. This study shows that HPV detection and genotyping in self-obtained cervicovaginal samples applied to an FTA cartridge is highly reliable. It shows a high level of overall agreement with HPV detection and genotyping in physician-obtained cervical smears and liquid-based self-samples. DNA can be obtained by simple elution and is therefore easy, cheap, and fast. Furthermore, the FTA cartridge is a convenient medium for collection and safe transport at ambient temperatures. Therefore, this method may contribute to a new way of cervical cancer screening. PMID:19553570

  5. Use of an Ultrasonic/Sonic Driller/Corer to Obtain Sample Powder for CHEMIN, a Combined XRD/XRF Instrument

    Science.gov (United States)

    Chipera, S. J.; Bish, D. L.; Vaniman, D. T.; Sherrit, S.; Bar-Cohen, Y.; Sarrazin, P.; Blake, D. F.

    2003-01-01

    A miniature CHEMIN XRD/XRF (X-Ray Diffraction/X-Ray Fluourescence) instrument is currently being developed for definitive mineralogic analysis of soils and rocks on Mars. One of the technical issues that must be addressed in order to enable XRD analysis on an extraterrestrial body is how best to obtain a representative sample powder for analysis. For XRD powder diffraction analyses, it is beneficial to have a fine-grained sample to reduce preferred orientation effects and to provide a statistically significant number of crystallites to the X-ray beam. Although a 2-dimensional detector as used in the CHEMIN instrument will produce good results with poorly prepared powders, the quality of the data will improve if the sample is fine-grained and randomly oriented. An Ultrasonic/Sonic Driller/Corer (USDC) currently being developed at JPL is an effective mechanism of sampling rock to produce cores and powdered cuttings. It requires low axial load (XRD/XRF spectrometer such as CHEMIN, powders obtained from the JPL ultrasonic drill were analyzed and the results were compared to carefully prepared powders obtained using a laboratory bench scale Retsch mill.

  6. Specific heat capacities of different clayey samples obtained by differential scanning calorimetry

    International Nuclear Information System (INIS)

    Fernandez, A.M.

    2012-01-01

    Document available in extended abstract form only. The thermo-physical properties allow to calculate heat flows and to determine the thermal behaviour of the materials. Temperature influences the rates of the physical, chemical and biological reactions and processes in the soil or a material. Variations in temperature and water content in thermal, hydraulic, mechanical and geochemical processes affect the thermal properties such as density, specific heat, thermal conductivity and thermal diffusivity. Therefore, mathematical models that describe the dependence of the thermal properties on temperature and concentration are of interest to be used in computational programs applied to the modelling of coupled thermo-mechanical-hydraulic and chemical (THMC) processes. In this work, the specific heat capacity of different clayey international reference materials was determined. Differential Scanning Calorimetry (DSC) was used for such purpose. DSC is the main tool for determining the specific heat capacities of materials as a function of temperature. The specific heat capacity, c p (J/Kg.K), is a measurement of the amount of heat required to raise the temperature of a unit mass of a substance by one unit of temperature. A change in temperature, caused by a gain or a loss of heat from a material, depends on the specific heat capacity of the material. Thus, the specific heat capacity is a key and characteristic property of a material and/or substance, which should be determine accurately. The specific heat capacity is an intensive property and, unlike the thermal conductivity and thermal diffusivity, is independent of the dry density of the material. C p of the solid samples was determined by using a SETSYS Evolution 16 thermal analyser coupled to a differential scanning calorimeter (TG-DSC-DTA) from SETARAM Instrumentation. The thermal analyser system can use a heating rate from 0.01 to 100 C/min under a dynamic argon atmosphere and temperatures ranging from ambient to

  7. Utility of the microculture method in non-invasive samples obtained from an experimental murine model with asymptomatic leishmaniasis.

    Science.gov (United States)

    Allahverdiyev, Adil M; Bagirova, Malahat; Cakir-Koc, Rabia; Elcicek, Serhat; Oztel, Olga Nehir; Canim-Ates, Sezen; Abamor, Emrah Sefik; Yesilkir-Baydar, Serap

    2012-07-01

    The sensitivity of diagnostic methods for visceral leishmaniasis (VL) decreases because of the low number of parasites and antibody amounts in asymptomatic healthy donors who are not suitable for invasive sample acquisition procedures. Therefore, new studies are urgently needed to improve the sensitivity and specificity of the diagnostic approaches in non-invasive samples. In this study, the sensitivity of the microculture method (MCM) was compared with polymerase chain reaction (PCR), enzyme-linked immunosorbent assay (ELISA), and immunofluorescent antibody test (IFAT) methods in an experimental murine model with asymptomatic leishmaniasis. Results showed that the percent of positive samples in ELISA, IFAT, and peripheral blood (PB) -PCR tests were 17.64%, 8.82%, and 5.88%, respectively, whereas 100% positive results were obtained with MCM and MCM-PCR methods. Thus, this study, for the first time, showed that MCM is more sensitive, specific, and economic than other methods, and the sensitivity of PCR that was performed to samples obtained from MCM was higher than sensitivity of the PCR method sampled by PB.

  8. On Invertible Sampling and Adaptive Security

    DEFF Research Database (Denmark)

    Ishai, Yuval; Kumarasubramanian, Abishek; Orlandi, Claudio

    2011-01-01

    functionalities was left open. We provide the first convincing evidence that the answer to this question is negative, namely that some (randomized) functionalities cannot be realized with adaptive security. We obtain this result by studying the following related invertible sampling problem: given an efficient...... sampling algorithm A, obtain another sampling algorithm B such that the output of B is computationally indistinguishable from the output of A, but B can be efficiently inverted (even if A cannot). This invertible sampling problem is independently motivated by other cryptographic applications. We show......, under strong but well studied assumptions, that there exist efficient sampling algorithms A for which invertible sampling as above is impossible. At the same time, we show that a general feasibility result for adaptively secure MPC implies that invertible sampling is possible for every A, thereby...

  9. Quality of determinations obtained from laboratory reference samples used in the calibration of X-ray electron probe microanalysis of silicate minerals

    International Nuclear Information System (INIS)

    Pavlova, Ludmila A.; Suvorova, Ludmila F.; Belozerova, Olga Yu.; Pavlov, Sergey M.

    2003-01-01

    Nine simple minerals and oxides, traditionally used as laboratory reference samples in the electron probe microanalysis (EPMA) of silicate minerals, have been quantitatively evaluated. Three separate series of data, comprising the average concentration, standard deviation, relative standard deviation, confidence interval and the z-score of data quality, were calculated for 21 control samples derived from calibrations obtained from three sets of reference samples: (1) simple minerals; (2) oxides; and (3) certified glass reference materials. No systematic difference was observed between the concentrations obtained from these three calibration sets when analyzed results were compared to certified compositions. The relative standard deviations obtained for each element were smaller than target values for all determinations. The z-score values for all elements determined fell within acceptable limits (-2< z<2) for concentrations ranging from 0.1 to 100%. These experiments show that the quality of data obtained from laboratory reference calibration samples is not inferior to that from certified reference glasses. The quality of results obtained corresponds to the 'applied geochemistry' type of analysis (category 2) as defined in the GeoPT proficiency testing program. Therefore, the laboratory reference samples can be used for calibrating EPMA techniques in the analysis of silicate minerals and for controlling the quality of results

  10. Interpolation and sampling in spaces of analytic functions

    CERN Document Server

    Seip, Kristian

    2004-01-01

    The book is about understanding the geometry of interpolating and sampling sequences in classical spaces of analytic functions. The subject can be viewed as arising from three classical topics: Nevanlinna-Pick interpolation, Carleson's interpolation theorem for H^\\infty, and the sampling theorem, also known as the Whittaker-Kotelnikov-Shannon theorem. The book aims at clarifying how certain basic properties of the space at hand are reflected in the geometry of interpolating and sampling sequences. Key words for the geometric descriptions are Carleson measures, Beurling densities, the Nyquist rate, and the Helson-Szegő condition. The book is based on six lectures given by the author at the University of Michigan. This is reflected in the exposition, which is a blend of informal explanations with technical details. The book is essentially self-contained. There is an underlying assumption that the reader has a basic knowledge of complex and functional analysis. Beyond that, the reader should have some familiari...

  11. The Moderating Effect of Chronological Age on the Relation Between Neuroticism and Physical Functioning: Cross-Sectional Evidence From Two French Samples.

    Science.gov (United States)

    Canada, Brice; Stephan, Yannick; Jaconelli, Alban; Duberstein, Paul R

    2016-01-01

    Prior studies of age-restricted samples have demonstrated that, in older adulthood, neuroticism is negatively associated with difficulties performing specific daily activities. No studies of neuroticism and physical functioning have been conducted on life-span samples. This study tested the hypothesis that the relationship between neuroticism and physical functioning is stronger in older people compared with younger and middle-aged adults. Data were obtained from 2 independent French samples (n = 1,132 and 1,661 for Samples 1 and 2, respectively) ranging in age from 18 to 97. In addition to reporting sociodemographics, participants completed the Big Five Inventory, the physical functioning scale of the 36-Item Short Form Health Survey, and measures of disease burden. In both samples, regression analysis indicated that neuroticism is more negatively associated with physical functioning with advancing age, controlling for gender, marital status, disease burden, and educational attainment. In life-span samples of more than 2,700 adults, neuroticism was more strongly associated with worse physical functioning among older people compared with younger and middle-aged adults. Longitudinal research is needed to confirm this finding and to identify potential mediators. © The Author 2014. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. The use of importance sampling in a trial assessment to obtain converged estimates of radiological risk

    International Nuclear Information System (INIS)

    Johnson, K.; Lucas, R.

    1986-12-01

    In developing a methodology for assessing potential sites for the disposal of radioactive wastes, the Department of the Environment has conducted a series of trial assessment exercises. In order to produce converged estimates of radiological risk using the SYVAC A/C simulation system an efficient sampling procedure is required. Previous work has demonstrated that importance sampling can substantially increase sampling efficiency. This study used importance sampling to produce converged estimates of risk for the first DoE trial assessment. Four major nuclide chains were analysed. In each case importance sampling produced converged risk estimates with between 10 and 170 times fewer runs of the SYVAC A/C model. This increase in sampling efficiency can reduce the total elapsed time required to obtain a converged estimate of risk from one nuclide chain by a factor of 20. The results of this study suggests that the use of importance sampling could reduce the elapsed time required to perform a risk assessment of a potential site by a factor of ten. (author)

  13. Functional nanostructured titanium nitride films obtained by sputtering magnetron

    International Nuclear Information System (INIS)

    Sanchez, O.; Hernandez-Velez, M.; Navas, D.; Auger, M.A.; Baldonedo, J.L.; Sanz, R.; Pirota, K.R.; Vazquez, M.

    2006-01-01

    Development of new methods in the formation of hollow structures, in particular, nanotubes and nanocages are currently generating a great interest as a consequence of the growing relevance of these nanostructures on many technological fields, ranging from optoelectronics to biotechnology. In this work, we report the formation of titanium nitride (TiN) nanotubes and nanohills via reactive sputtering magnetron processes. Anodic Alumina Membranes (AAM) were used as template substrates to grow the TiN nanostructures. The AAM were obtained through electrochemical anodization processes by using oxalic acid solutions as electrolytes. The nanotubes were produced at temperatures below 100 deg. C, and using a pure titanium (99.995%) sputtering target and nitrogen as reactive gas. The obtained TiN thin films showed surface morphologies adjusted to pore diameter and interpore distance of the substrates, as well as ordered arrays of nanotubes or nanohills depending on the sputtering and template conditions. High Resolution Scanning Electron Microscopy (HRSEM) was used to elucidate both the surface order and morphology of the different grown nanostructures. The crystalline structure of the samples was examined using X-ray Diffraction (XRD) patterns and their qualitative chemical composition by using X-ray Energy Dispersive Spectroscopy (XEDS) in a scanning electron microscopy

  14. Evaluation of the Validity of Groundwater Samples Obtained Using the Purge Water Management System at SRS

    International Nuclear Information System (INIS)

    Beardsley, C.C.

    1999-01-01

    As part of the demonstration testing of the Purge Water Management System (PWMS) technology at the Savannah River Site (SRS), four wells were equipped with PWMS units in 1997 and a series of sampling events were conducted at each during 1997-1998. Three of the wells were located in A/M Area while the fourth was located at the Old Radioactive Waste Burial Ground in the General Separations Area.The PWMS is a ''closed-loop'', non-contact, system used to collect and return purge water to the originating aquifer after a sampling event without having significantly altered the water quality. One of the primary concerns as to its applicability at SRS, and elsewhere, is whether the PWMS might resample groundwater that is returned to the aquifer during the previous sampling event. The purpose of the present investigation was to compare groundwater chemical analysis data collected at the four test wells using the PWMS vs. historical data collected using the standard monitoring program methodology to determine if the PWMS provides representative monitoring samples.The analysis of the groundwater chemical concentrations indicates that the PWMS sampling methodology acquired representative groundwater samples at monitoring wells ABP-1A, ABP-4, ARP-3 and BGO-33C. Representative groundwater samples are achieved if the PWMS does not resample groundwater that has been purged and returned during a previous sampling event. Initial screening calculations, conducted prior to the selection of these four wells, indicated that groundwater velocities were high enough under the ambient hydraulic gradients to preclude resampling from occurring at the time intervals that were used at each well. Corroborating evidence included a tracer test that was conducted at BGO-33C, the high degree of similarity between analyte concentrations derived from the PWMS samples and those obtained from historical protocol sampling, as well as the fact that PWMS data extend all previously existing concentration

  15. Obtaining Self-Samples to Diagnose Curable Sexually Transmitted Infections: A Systematic Review of Patients’ Experiences

    Science.gov (United States)

    Paudyal, Priyamvada; Llewellyn, Carrie; Lau, Jason; Mahmud, Mohammad; Smith, Helen

    2015-01-01

    Background Routine screening is key to sexually transmitted infection (STI) prevention and control. Previous studies suggest that clinic-based screening programmes capture only a small proportion of people with STIs. Self-sampling using non- or minimally invasive techniques may be beneficial for those reluctant to actively engage with conventional sampling methods. We systematically reviewed studies of patients’ experiences of obtaining self-samples to diagnose curable STIs. Methods We conducted an electronic search of MEDLINE, EMBASE, CINAHL, PsychINFO, BNI, and Cochrane Database of Systematic Reviews to identify relevant articles published in English between January 1980 and March 2014. Studies were included if participants self-sampled for the diagnosis of a curable STI and had specifically sought participants’ opinions of their experience, acceptability, preferences, or willingness to self-sample. Results The initial search yielded 558 references. Of these, 45 studies met the inclusion criteria. Thirty-six studies assessed patients’ acceptability and experiences of self-sampling. Pooled results from these studies shows that self-sampling is a highly acceptable method with 85% of patients reporting the method to be well received and acceptable. Twenty-eight studies reported on ease of self-sampling; the majority of patients (88%) in these studies found self-sampling an “easy” procedure. Self-sampling was favoured compared to clinician sampling, and home sampling was preferred to clinic-based sampling. Females and older participants were more accepting of self-sampling. Only a small minority of participants (13%) reported pain during self-sampling. Participants were willing to undergo self-sampling and recommend others. Privacy and safety were the most common concerns. Conclusion Self-sampling for diagnostic testing is well accepted with the majority having a positive experience and willingness to use again. Standardization of self-sampling procedures

  16. No upregulation of digitalis glycoside receptor (Na,K-ATPase) concentration in human heart left ventricle samples obtained at necropsy after long term digitalisation.

    Science.gov (United States)

    Schmidt, T A; Holm-Nielsen, P; Kjeldsen, K

    1991-08-01

    The aim was to evaluate the hypothesis that digitalis glycosides increase the concentration of their specific receptor (Na,K-ATPase) in human myocardial tissue, thereby possibly reducing the inotropic effect of long term digitalis treatment. Intact samples of left ventricle were obtained at necropsy from patients who had been on long term treatment with digoxin and from patients not previously given digoxin. Digitalis glycoside receptors were quantified using vanadate facilitated 3H-ouabain binding before and after washing samples in buffer containing excess digoxin antibody fragments for 16 h at 30 degrees C. This washing procedure has previously been shown to reduce prior specific digoxin binding in human left ventricle by 95% and to allow subsequent vanadate facilitated complete quantification of 3H-ouabain binding sites. In this context it was performed to reduce occupancy of digitalis glycoside receptors by digoxin, caused by digitalisation before 3H-ouabain binding. 11 patients who had been on long term treatment with digoxin and eight who had not previously been given digoxin were studied. Left ventricle samples were obtained at necropsy at around 15 h after death. Standard 3H-ouabain binding was 39% less in samples from digitalised than from undigitalised subjects (p less than 0.001). Washing samples in buffer containing excess digoxin antibody fragments induced an increase in 3H-ouabain binding from 174(SEM 10) to 265(20) pmol.g-1 wet weight (n = 11, p less than 0.001) in samples from digitalised patients. After washing, the digitalis glycoside receptor concentration in left ventricle samples showed a tendency to a lower value (14%, p greater than 0.10) in patients exposed to digoxin compared to left ventricle samples from individuals unexposed to digitalis glycoside treatment. Calculating 3H-ouabain binding relative to dry ventricular muscle weight confirmed the results obtained using wet weight as reference. The results suggest that digoxin treatment in

  17. An Optimized DNA Analysis Workflow for the Sampling, Extraction, and Concentration of DNA obtained from Archived Latent Fingerprints.

    Science.gov (United States)

    Solomon, April D; Hytinen, Madison E; McClain, Aryn M; Miller, Marilyn T; Dawson Cruz, Tracey

    2018-01-01

    DNA profiles have been obtained from fingerprints, but there is limited knowledge regarding DNA analysis from archived latent fingerprints-touch DNA "sandwiched" between adhesive and paper. Thus, this study sought to comparatively analyze a variety of collection and analytical methods in an effort to seek an optimized workflow for this specific sample type. Untreated and treated archived latent fingerprints were utilized to compare different biological sampling techniques, swab diluents, DNA extraction systems, DNA concentration practices, and post-amplification purification methods. Archived latent fingerprints disassembled and sampled via direct cutting, followed by DNA extracted using the QIAamp® DNA Investigator Kit, and concentration with Centri-Sep™ columns increased the odds of obtaining an STR profile. Using the recommended DNA workflow, 9 of the 10 samples provided STR profiles, which included 7-100% of the expected STR alleles and two full profiles. Thus, with carefully selected procedures, archived latent fingerprints can be a viable DNA source for criminal investigations including cold/postconviction cases. © 2017 American Academy of Forensic Sciences.

  18. Assessment of left ventricular function and mass by MR imaging: a stereological study based on the systematic slice sampling procedure.

    Science.gov (United States)

    Mazonakis, Michalis; Sahin, Bunyamin; Pagonidis, Konstantin; Damilakis, John

    2011-06-01

    The aim of this study was to combine the stereological technique with magnetic resonance (MR) imaging data for the volumetric and functional analysis of the left ventricle (LV). Cardiac MR examinations were performed in 13 consecutive subjects with known or suspected coronary artery disease. The end-diastolic volume (EDV), end-systolic volume, ejection fraction (EF), and mass were estimated by stereology using the entire slice set depicting LV and systematic sampling intensities of 1/2 and 1/3 that provided samples with every second and third slice, respectively. The repeatability of stereology was evaluated. Stereological assessments were compared with the reference values derived by manually tracing the endocardial and epicardial contours on MR images. Stereological EDV and EF estimations obtained by the 1/3 systematic sampling scheme were significantly different from those by manual delineation (P sampling intensity of 1/2 (P > .05). For these stereological approaches, a high correlation (r(2) = 0.80-0.93) and clinically acceptable limits of agreement were found with the reference method. Stereological estimations obtained by both sample sizes presented comparable coefficient of variation values of 2.9-5.8%. The mean time for stereological measurements on the entire slice set was 3.4 ± 0.6 minutes and it was reduced to 2.5 ± 0.5 minutes with the 1/2 systematic sampling scheme. Stereological analysis on systematic samples of MR slices generated by the 1/2 sampling intensity provided efficient and quick assessment of LV volumes, function, and mass. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  19. Functions with disconnected spectrum sampling, interpolation, translates

    CERN Document Server

    Olevskii, Alexander M

    2016-01-01

    The classical sampling problem is to reconstruct entire functions with given spectrum S from their values on a discrete set L. From the geometric point of view, the possibility of such reconstruction is equivalent to determining for which sets L the exponential system with frequencies in L forms a frame in the space L^2(S). The book also treats the problem of interpolation of discrete functions by analytic ones with spectrum in S and the problem of completeness of discrete translates. The size and arithmetic structure of both the spectrum S and the discrete set L play a crucial role in these problems. After an elementary introduction, the authors give a new presentation of classical results due to Beurling, Kahane, and Landau. The main part of the book focuses on recent progress in the area, such as construction of universal sampling sets, high-dimensional and non-analytic phenomena. The reader will see how methods of harmonic and complex analysis interplay with various important concepts in different areas, ...

  20. Minimally processed beetroot waste as an alternative source to obtain functional ingredients.

    Science.gov (United States)

    Costa, Anne Porto Dalla; Hermes, Vanessa Stahl; Rios, Alessandro de Oliveira; Flôres, Simone Hickmann

    2017-06-01

    Large amounts of waste are generated by the minimally processed vegetables industry, such as those from beetroot processing. The aim of this study was to determine the best method to obtain flour from minimally processed beetroot waste dried at different temperatures, besides producing a colorant from such waste and assessing its stability along 45 days. Beetroot waste dried at 70 °C originates flour with significant antioxidant activity and higher betalain content than flour produced from waste dried at 60 and 80 °C, while chlorination had no impact on the process since microbiological results were consistent for its application. The colorant obtained from beetroot waste showed color stability for 20 days and potential antioxidant activity over the analysis period, thus it can be used as a functional additive to improve nutritional characteristics and appearance of food products. These results are promising since minimally processed beetroot waste can be used as an alternative source of natural and functional ingredients with high antioxidant activity and betalain content.

  1. The use of human samples obtained during medicolegal autopsies in research: An introduction to current conditions and initiatives in Japan.

    Science.gov (United States)

    Tsujimura-Ito, Takako; Inoue, Yusuke; Muto, Kaori; Yoshida, Ken-Ichi

    2017-04-01

    Background Leftover samples obtained during autopsies are extremely important basic materials for forensic research. However, there are no established practices for research-related use of obtained samples. Objective This study discusses good practice for the secondary use of samples collected during medicolegal autopsies. Methods A questionnaire was posted to all 76 departments of forensic medicine performing medicolegal autopsies in Japan, and 48 responses were received (response rate: 63.2%). As a secondary analysis, we surveyed information provided on department websites. Results Ethical reviews conducted when samples were to be used for research varied greatly among departments, with 21 (43.8%) departments reporting 'fundamentally, all cases are subject to review', eight (16.7%) reporting 'only some are subject to review' and 17 (39.6%) reporting 'none are subject to review'. Information made available on websites indicated that 11 departments had a statement of some type to bereaved families about the potential research use of human samples obtained during autopsies. Nine of these included a notice stating that bereaved families may revoke their consent for use. Several departments used an opt-out system. Conclusion There is no common practice in the field of legal medicine on the ethical use for medical research of leftover samples from medicolegal autopsies. The trust of not only bereaved families but also society in general is required for the scientific validity and social benefits of medical studies using leftover samples from medicolegal autopsies through the use of opt-out consenting and offline and online dissemination and public-relations activities.

  2. Parameterized hemodynamic response function data of healthy individuals obtained from resting-state functional MRI in a 7T MRI scanner

    Directory of Open Access Journals (Sweden)

    D. Rangaprakash

    2018-04-01

    Full Text Available Functional magnetic resonance imaging (fMRI, being an indirect measure of brain activity, is mathematically defined as a convolution of the unmeasured latent neural signal and the hemodynamic response function (HRF. The HRF is known to vary across the brain and across individuals, and it is modulated by neural as well as non-neural factors. Three parameters characterize the shape of the HRF, which is obtained by performing deconvolution on resting-state fMRI data: response height, time-to-peak and full-width at half-max. The data provided here, obtained from 47 healthy adults, contains these three HRF parameters at every voxel in the brain, as well as HRF parameters from the default-mode network (DMN. In addition, we have provided functional connectivity (FC data from the same DMN regions, obtained for two cases: data with deconvolution (HRF variability minimized and data with no deconvolution (HRF variability corrupted. This would enable researchers to compare regional changes in HRF with corresponding FC differences, to assess the impact of HRF variability on FC. Importantly, the data was obtained in a 7T MRI scanner. While most fMRI studies are conducted at lower field strengths, like 3T, ours is the first study to report HRF data obtained at 7T. FMRI data at ultra-high fields contains larger contributions from small vessels, consequently HRF variability is lower for small vessels at higher field strengths. This implies that findings made from this data would be more conservative than from data acquired at lower fields, such as 3T. Results obtained with this data and further interpretations are available in our recent research study (Rangaprakash et al., in press [1]. This is a valuable dataset for studying HRF variability in conjunction with FC, and for developing the HRF profile in healthy individuals, which would have direct implications for fMRI data analysis, especially resting-state connectivity modeling. This is the first public HRF

  3. The quasar luminosity function from a variability-selected sample

    Science.gov (United States)

    Hawkins, M. R. S.; Veron, P.

    1993-01-01

    A sample of quasars is selected from a 10-yr sequence of 30 UK Schmidt plates. Luminosity functions are derived in several redshift intervals, which in each case show a featureless power-law rise towards low luminosities. There is no sign of the 'break' found in the recent UVX sample of Boyle et al. It is suggested that reasons for the disagreement are connected with biases in the selection of the UVX sample. The question of the nature of quasar evolution appears to be still unresolved.

  4. Utility of the microculture method for Leishmania detection in non-invasive samples obtained from a blood bank.

    Science.gov (United States)

    Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Kocazeybek, Bekir; Kosan, Erdogan

    2013-10-01

    In recent years, the role of donor blood has taken an important place in epidemiology of Leishmaniasis. According to the WHO, the numbers of patients considered as symptomatic are only 5-20% of individuals with asymptomatic leishmaniasis. In this study for detection of Leishmania infection in donor blood samples, 343 samples from the Capa Red Crescent Blood Center were obtained and primarily analyzed by microscopic and serological methods. Subsequently, the traditional culture (NNN), Immuno-chromatographic test (ICT) and Polymerase Chain Reaction (PCR) methods were applied to 21 samples which of them were found positive with at least one method. Buffy coat (BC) samples from 343 blood donors were analyzed: 15 (4.3%) were positive by a microculture method (MCM); and 4 (1.1%) by smear. The sera of these 343 samples included 9 (2.6%) determined positive by ELISA and 7 (2%) positive by IFAT. Thus, 21 of (6.1%) the 343 subjects studied by smear, MCM, IFAT and ELISA techniques were identified as positive for leishmaniasis at least one of the techniques and the sensitivity assessed. According to our data, the sensitivity of the methods are identified as MCM (71%), smear (19%), IFAT (33%), ELISA (42%), NNN (4%), PCR (14%) and ICT (4%). Thus, with this study for the first time, the sensitivity of a MCM was examined in blood donors by comparing MCM with the methods used in the diagnosis of leishmaniasis. As a result, MCM was found the most sensitive method for detection of Leishmania parasites in samples obtained from a blood bank. In addition, the presence of Leishmania parasites was detected in donor bloods in Istanbul, a non-endemic region of Turkey, and these results is a vital importance for the health of blood recipients. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Short communication: Comparison of pH, volatile fatty acids, and microbiome of rumen samples from preweaned calves obtained via cannula or stomach tube.

    Science.gov (United States)

    Terré, M; Castells, L; Fàbregas, F; Bach, A

    2013-08-01

    The objective of this study was to compare rumen samples from young dairy calves obtained via a stomach tube (ST) or a ruminal cannula (RC). Five male Holstein calves (46±4.0 kg of body weight and 11±4.9 d of age) were ruminally cannulated at 15 d of age. Calves received 4 L/d of a commercial milk replacer (25% crude protein and 19.2% fat) at 12.5% dry matter, and were provided concentrate and chopped oats hay ad libitum throughout the study (56 d). In total, 29 paired rumen samples were obtained weekly throughout the study in most of the calves by each extraction method. These samples were used to determine pH and volatile fatty acids (VFA) concentration, and to quantify Prevotella ruminicola and Streptococcus bovis by quantitative PCR. Furthermore, a denaturing gradient gel electrophoresis was performed on rumen samples harvested during wk 8 of the study to determine the degree of similarity between rumen bacteria communities. Rumen pH was 0.30 units greater in ST compared with RC samples. Furthermore, total VFA concentrations were greater in RC than in ST samples. However, when analyzing the proportion of each VFA by ANOVA, no differences were found between the sampling methods. The quantification of S. bovis and P. ruminicola was similar in both extraction methods, and values obtained using different methods were highly correlated (R(2)=0.89 and 0.98 for S. bovis and P. ruminicola, respectively). Fingerprinting analysis showed similar bacteria band profiles between samples obtained from the same calves using different extraction methods. In conclusion, when comparing rumen parameters obtained using different sampling techniques, it is recommended that VFA profiles be used rather than total VFA concentrations, as total VFA concentrations are more affected by the method of collection. Furthermore, although comparisons of pH across studies should be avoided when samples are not obtained using the same sampling method, the comparison of fingerprinting of a

  6. Obtaining parton distribution functions from self-organizing maps

    International Nuclear Information System (INIS)

    Honkanen, H.; Liuti, S.; Loitiere, Y.C.; Brogan, D.; Reynolds, P.

    2007-01-01

    We present an alternative algorithm to global fitting procedures to construct Parton Distribution Functions parametrizations. The proposed algorithm uses Self-Organizing Maps which at variance with the standard Neural Networks, are based on competitive-learning. Self-Organizing Maps generate a non-uniform projection from a high dimensional data space onto a low dimensional one (usually 1 or 2 dimensions) by clustering similar PDF representations together. The SOMs are trained on progressively narrower selections of data samples. The selection criterion is that of convergence towards a neighborhood of the experimental data. All available data sets on deep inelastic scattering in the kinematical region of 0.001 ≤ x ≤ 0.75, and 1 ≤ Q 2 ≤ 100 GeV 2 , with a cut on the final state invariant mass, W 2 ≥ 10 GeV 2 were implemented. The proposed fitting procedure, at variance with standard neural network approaches, allows for an increased control of the systematic bias by enabling the user to directly control the data selection procedure at various stages of the process. (author)

  7. Functional magnetic resonance maps obtained by personal computer

    International Nuclear Information System (INIS)

    Gomez, F. j.; Manjon, J. V.; Robles, M.; Marti-Bonmati, L.; Dosda, R.; Molla, E.

    2001-01-01

    Functional magnetic resonance (fMR) is of special relevance in the analysis of certain types of brain activation. The present report describes the development of a simple software program for use with personal computers (PCs) that analyzes these images and provides functional activation maps. Activation maps are based on the temporal differences in oxyhemoglobin in tomographic images. To detect these differences, intensities registered repeatedly during brain control and activation are compared. The experiments were performed with a 1.5-Tesla MR unit. To verify the reliability of the program fMR studies were carried out in 4 healthy individuals (12 contiguous slices, 80 images per slice every 3.1 seconds for a total of 960 images). All the images were transferred to a PC and were processed pixel by pixel within each sequence to obtain an intensity/time curve. The statistical study of the results (Student's test and cross correlation analysis) made it possible to establish the activation of each pixel. The images were prepared using spatial filtering, temporal filtering, baseline correction, normalization and segmentation of the parenchyma. The postprocessing of the results involved the elimination of single pixels, superposition of an anatomical image of greater spatial resolution and anti-aliasing. The application (Xfun 1.0, Valencia, Spain) was developed in Microsoft Visual C++5.0 Developer Studio for Windows NT Workstation. As a representative example, the program took 8.2 seconds to calculate and present the results of the entire study (12 functional maps). In the motor and visual activation experiments, the activation corresponding to regions proximal to the central sulcus of the hemisphere contralateral to the hand that moved and in the occipital cortex were observed. While programs that calculate activation maps are available, the development of software for PCs running Microsoft Windows ensures several key features for its use on a daily basis: it is easy

  8. Two sample Bayesian prediction intervals for order statistics based on the inverse exponential-type distributions using right censored sample

    Directory of Open Access Journals (Sweden)

    M.M. Mohie El-Din

    2011-10-01

    Full Text Available In this paper, two sample Bayesian prediction intervals for order statistics (OS are obtained. This prediction is based on a certain class of the inverse exponential-type distributions using a right censored sample. A general class of prior density functions is used and the predictive cumulative function is obtained in the two samples case. The class of the inverse exponential-type distributions includes several important distributions such the inverse Weibull distribution, the inverse Burr distribution, the loglogistic distribution, the inverse Pareto distribution and the inverse paralogistic distribution. Special cases of the inverse Weibull model such as the inverse exponential model and the inverse Rayleigh model are considered.

  9. Rapid Fractionation and Isolation of Whole Blood Components in Samples Obtained from a Community-based Setting.

    Science.gov (United States)

    Weckle, Amy; Aiello, Allison E; Uddin, Monica; Galea, Sandro; Coulborn, Rebecca M; Soliven, Richelo; Meier, Helen; Wildman, Derek E

    2015-11-30

    Collection and processing of whole blood samples in a non-clinical setting offers a unique opportunity to evaluate community-dwelling individuals both with and without preexisting conditions. Rapid processing of these samples is essential to avoid degradation of key cellular components. Included here are methods for simultaneous peripheral blood mononuclear cell (PBMC), DNA, RNA and serum isolation from a single blood draw performed in the homes of consenting participants across a metropolitan area, with processing initiated within 2 hr of collection. We have used these techniques to process over 1,600 blood specimens yielding consistent, high quality material, which has subsequently been used in successful DNA methylation, genotyping, gene expression and flow cytometry analyses. Some of the methods employed are standard; however, when combined in the described manner, they enable efficient processing of samples from participants of population- and/or community-based studies who would not normally be evaluated in a clinical setting. Therefore, this protocol has the potential to obtain samples (and subsequently data) that are more representative of the general population.

  10. Study of the behavior to corrosion of samples of nuclear grade aluminium sheathed in nickel-phosphorous alloys obtained autocatalytically

    International Nuclear Information System (INIS)

    Castro, Maria Eugenia; Barbero, Jose Alfredo; Bubach, Ernesto

    2006-01-01

    One of the ways to protect an industrially important metallic material against corrosion is by covering the piece with an approximately 1 μm layer of a material whose resistance to corrosion is greater than the element being protected. The mechanism by which the anticorrosive protection is obtained is with the formation of a pore free physical barrier without defects that impedes the arrival of the agents responsible for the electrochemical attack. Other sacrifice anodes such as aluminum or zinc have protective forms based on their dissolution as a consequence of their less electrochemically noble behavior to preserve the material. This work studies the resistance to the corrosion of metallic coatings on nuclear grade aluminum substrates. The focus is on coating nickel-phosphorous (ni-P) alloys obtained autocatalytically from aluminum 6061. A comparative study is carried out of a series of electroless nickel coatings containing different amounts of the latter element, but without surpassing the threshold of 12%. The work includes the study of another nickel coating, Vitrovac 0080 (without phosphorous content) in order to compare structures and anticorrosive properties. These materials are also compared with the Al6061 substrate without any kind of coating. The study is carried out with surface characterization of each one of the samples with or without coating using a series of complementary techniques, such as chemical and electrochemical techniques (linear-sweep voltammetry, cyclic voltammetry, determination of the polarization resistance) and physical techniques (SEM microscopy, determination of micro-hardness). The correlation of variables is carried out later as a function of the phosphorous content of the test samples. The structures obtained from the coatings are amorphous. They have no pores or faults and have high hardness values. The electrochemical study proves that the anticorrosive protection capacity of the Ni-P alloy increases along with the

  11. Modulation of Cytokine mRNA Expression in Pharyngeal Epithelial Samples obtained from Cattle Infected with Foot-and-Mouth Disease Virus

    DEFF Research Database (Denmark)

    Stenfeldt, Anna Carolina; Heegaard, Peter M. H.; Stockmarr, Anders

    2012-01-01

    A novel technique of endoscopical collection of small tissue samples was used to obtain sequential tissue samples from the dorsal soft palate (DSP) of individual cattle infected with foot-and-mouth disease virus (FMDV) at different phases of the infection. Levels of mRNA encoding interferon (IFN)...

  12. Casingless down-hole for sealing an ablation volume and obtaining a sample for analysis

    Science.gov (United States)

    Noble, Donald T.; Braymen, Steven D.; Anderson, Marvin S.

    1996-10-01

    A casing-less down hole sampling system for acquiring a subsurface sample for analysis using an inductively coupled plasma system is disclosed. The system includes a probe which is pushed into the formation to be analyzed using a hydraulic ram system. The probe includes a detachable tip member which has a soil point mad a barb, with the soil point aiding the penetration of the earth, and the barb causing the tip member to disengage from the probe and remain in the formation when the probe is pulled up. The probe is forced into the formation to be tested, and then pulled up slightly, to disengage the tip member and expose a column of the subsurface formation to be tested. An instrumentation tube mounted in the probe is then extended outward from the probe to longitudinally extend into the exposed column. A balloon seal mounted on the end of the instrumentation tube allows the bottom of the column to be sealed. A source of laser radiation is emitted from the instrumentation tube to ablate a sample from the exposed column. The instrumentation tube can be rotated in the probe to sweep the laser source across the surface of the exposed column. An aerosol transport system carries the ablated sample from the probe to the surface for testing in an inductively coupled plasma system. By testing at various levels in the down-hole as the probe is extracted from the soil, a profile of the subsurface formation may be obtained.

  13. Radiology compared with xenon—133 scanning and bronchoscopic lobar sampling as methods for assessing regional lung function in patients with emphysema

    Science.gov (United States)

    Barter, C. E.; Hugh-Jones, P.; Laws, J. W.; Crosbie, W. A.

    1973-01-01

    Regional lung function was assessed by radiographic methods, by regional function studies using xenon-133 scans, and by lobar sampling with a mass spectrometer flow-meter at bronchoscopy in 12 patients who subsequently had bullae resected at operation. The information given by these three methods of regional assessment was subsequently compared with the findings at operation. When only one lobe was abnormal on the radiographs, these alone were adequate to locate the major site of the emphysema and the regional tests gave relatively little extra information. The xenon scan was sometimes helpful in assessing the state of the remaining lung, but this information could be deduced from the radiographs and overall lung function tests, especially the carbon monoxide transfer and mechanical measurements. Bronchoscopic sampling was helpful in determining whether the affected lobe was acting as a ventilated dead-space. When more than one lobe was affected the regional function tests supplemented the radiographs in defining the site of bullous change as well as locating dead space. Xenon scans, although widely employed for such preoperative assessments, added little to the topographical information obtained by careful radiology. The combination of radiology, lobar sampling, and overall function tests is recommended for assessing which emphysematous patients are likely to benefit from surgery. Images PMID:4685209

  14. Time-dependent importance sampling in semiclassical initial value representation calculations for time correlation functions.

    Science.gov (United States)

    Tao, Guohua; Miller, William H

    2011-07-14

    An efficient time-dependent importance sampling method is developed for the Monte Carlo calculation of time correlation functions via the initial value representation (IVR) of semiclassical (SC) theory. A prefactor-free time-dependent sampling function weights the importance of a trajectory based on the magnitude of its contribution to the time correlation function, and global trial moves are used to facilitate the efficient sampling the phase space of initial conditions. The method can be generally applied to sampling rare events efficiently while avoiding being trapped in a local region of the phase space. Results presented in the paper for two system-bath models demonstrate the efficiency of this new importance sampling method for full SC-IVR calculations.

  15. Stationary and related stochastic processes sample function properties and their applications

    CERN Document Server

    Cramér, Harald

    2004-01-01

    This graduate-level text offers a comprehensive account of the general theory of stationary processes, with special emphasis on the properties of sample functions. Assuming a familiarity with the basic features of modern probability theory, the text develops the foundations of the general theory of stochastic processes, examines processes with a continuous-time parameter, and applies the general theory to procedures key to the study of stationary processes. Additional topics include analytic properties of the sample functions and the problem of time distribution of the intersections between a

  16. Differences in Neuropsychological Functioning Between Homicidal and Nonviolent Schizophrenia Samples.

    Science.gov (United States)

    Stratton, John; Cobia, Derin J; Reilly, James; Brook, Michael; Hanlon, Robert E

    2018-02-07

    Few studies have compared performance on neurocognitive measures between violent and nonviolent schizophrenia samples. A better understanding of neurocognitive dysfunction in violent individuals with schizophrenia could increase the efficacy of violence reduction strategies and aid in risk assessment and adjudication processes. This study aimed to compare neuropsychological performance between 25 homicide offenders with schizophrenia and 25 nonviolent schizophrenia controls. The groups were matched for age, race, sex, and handedness. Independent t-tests and Mann-Whitney U-tests were used to compare the schizophrenia groups' performance on measures of cognition, including composite scores assessing domain level functioning and individual neuropsychological tests. Results indicated the violent schizophrenia group performed worse on measures of memory and executive functioning, and the Intellectual Functioning composite score, when compared to the nonviolent schizophrenia sample. These findings replicate previous research documenting neuropsychological deficits specific to violent individuals with schizophrenia and support research implicating fronto-limbic dysfunction among violent offenders with schizophrenia. © 2018 American Academy of Forensic Sciences.

  17. Validity and Reliability of Scores Obtained on Multiple-Choice Questions: Why Functioning Distractors Matter

    Science.gov (United States)

    Ali, Syed Haris; Carr, Patrick A.; Ruit, Kenneth G.

    2016-01-01

    Plausible distractors are important for accurate measurement of knowledge via multiple-choice questions (MCQs). This study demonstrates the impact of higher distractor functioning on validity and reliability of scores obtained on MCQs. Freeresponse (FR) and MCQ versions of a neurohistology practice exam were given to four cohorts of Year 1 medical…

  18. Statistical identification of the confidence limits of open loop transfer functions obtained by MAR analysis

    International Nuclear Information System (INIS)

    Antonopoulos-Domis, M.; Mourtzanos, K.

    1996-01-01

    Estimators of the confidence limits of open loop transfer functions via Multivariate Auto-Regressive (MAR) modelling are not available in the literature. The statistics of open loop transfer functions obtained by MAR modelling are investigated via numerical experiments. A system of known open loop transfer functions is simulated digitally and excited by random number series. The digital signals of the simulated system are then MAR modelled and the open loop transfer functions are estimated. Performing a large number of realizations, mean values and variances of the open loop transfer functions are estimated. It is found that if the record length N of each realization is long enough then the estimates of open loop transfer functions follow normal distribution. The variance of the open loop transfer functions is proportional to 1/N. For MAR processes the asymptotic covariance matrix of the estimate of open loop transfer functions was found in agreement with theoretical prediction. (author)

  19. The ocean sampling day consortium

    DEFF Research Database (Denmark)

    Kopf, Anna; Bicak, Mesude; Kottmann, Renzo

    2015-01-01

    Ocean Sampling Day was initiated by the EU-funded Micro B3 (Marine Microbial Biodiversity, Bioinformatics, Biotechnology) project to obtain a snapshot of the marine microbial biodiversity and function of the world’s oceans. It is a simultaneous global mega-sequencing campaign aiming to generate...... the largest standardized microbial data set in a single day. This will be achievable only through the coordinated efforts of an Ocean Sampling Day Consortium, supportive partnerships and networks between sites. This commentary outlines the establishment, function and aims of the Consortium and describes our...

  20. Radiochemical data obtained by α spectrometry on unrecrystallized fossil coral samples from the Egyptian shoreline of the north-western Red Sea

    International Nuclear Information System (INIS)

    Choukri, A.; Hakam, O.K.; Reyss, J.L.; Plaziat, J.C.

    2007-01-01

    In this work, radiochemical results obtained by α spectrometry on 80 unrecrystallized fossil coral samples from the Egyptian shoreline of the north-western Red Sea are presented and discussed. The coral samples were collected in Egypt from the emerged 5e coral reef terraces over 500km from The Ras Gharib-Ras Shukeir depression (28 deg. 10 ' ) in the north to Wadi Lahami (north of Ras Banas, 24 deg. 10 ' ) in the south. The statistical description of radiochemical results (concentrations of U and Th radioisotopes, 234 U/ 238 U activity ratios and ages) obtained on a great number of coral samples showed that it is possible to establish methodological criterions which could be used to validate the measured ages before confronting them to the geological context of sampling sites. The obtained results confirm that the unrecrystallized corals ( 232 Th 238 U varies between 2.2 and 4.9ppm around an average of 3.18+/-0.65ppm. 234 U/ 238 U activity ratios are between 1.08 and 1.28 with an averaged value of 1.164+/-0.016 which exceeds that of present day sea water but which is in agreement with the ratio of 1.16 measured by a precise mass spectrometry in many Pleistocene coral samples. Except three samples dated at least 100ka, the radiochemical age of 5e coral samples vary between 108 and 131ka with an average value of 122.2ka and a standard deviation of 4.3ka. Except for samples from the Zeit area, the reef terrace is between 2 and 6m above the present sea level. This position is similar to the highest sea level from the last interglacial according to the glacio-isostatic rebound calculated for stable regions. This work proves that the large tectonic motions which affected the studied area after the Oligocene ceased after at least the last interglacial period

  1. A Sequential Optimization Sampling Method for Metamodels with Radial Basis Functions

    Science.gov (United States)

    Pan, Guang; Ye, Pengcheng; Yang, Zhidong

    2014-01-01

    Metamodels have been widely used in engineering design to facilitate analysis and optimization of complex systems that involve computationally expensive simulation programs. The accuracy of metamodels is strongly affected by the sampling methods. In this paper, a new sequential optimization sampling method is proposed. Based on the new sampling method, metamodels can be constructed repeatedly through the addition of sampling points, namely, extrema points of metamodels and minimum points of density function. Afterwards, the more accurate metamodels would be constructed by the procedure above. The validity and effectiveness of proposed sampling method are examined by studying typical numerical examples. PMID:25133206

  2. Hair of the dog: obtaining samples from coyotes and wolves noninvasively

    Science.gov (United States)

    Ausband, David E.; Young, Julie; Fannin, Barbara; Mitchell, Michael S.; Stenglein, Jennifer L.; Waits, Lisette P.; Shivik, John A.

    2011-01-01

    Canids can be difficult to detect and their populations difficult to monitor. We tested whether hair samples could be collected from coyotes (Canis latrans) in Texas, USA and gray wolves (C. lupus) in Montana, USA using lure to elicit rubbing behavior at both man-made and natural collection devices. We used mitochondrial and nuclear DNA to determine whether collected hair samples were from coyote, wolf, or nontarget species. Both coyotes and wolves rubbed on man-made barbed surfaces but coyotes in Texas seldom rubbed on hanging barbed surfaces. Wolves in Montana showed a tendency to rub at stations where natural-material collection devices (sticks and debris) were present. Time to detection was relatively short (5 nights and 4 nights for coyotes and wolves, respectively) with nontarget and unknown species comprising approximately 26% of the detections in both locations. Eliciting rubbing behavior from coyotes and wolves using lures has advantages over opportunistic genetic sampling methods (e.g., scat transects) because it elicits a behavior that deposits a hair sample at a fixed sampling location, thereby increasing the efficiency of sampling for these canids. Hair samples from rub stations could be used to provide estimates of abundance, measures of genetic diversity and health, and detection-nondetection data useful for cost-effective population monitoring.

  3. Influence of sintering parameters in the ferroelectric properties os strontium bismuth tantalate samples obtained by oxide mixture

    International Nuclear Information System (INIS)

    Souza, R.R. de; Pereira, A.S.; Sousa, V.C.; Egea, J.R.J.

    2012-01-01

    The family of compounds layered-type perovskite, know as Aurivilius presents great alternative not only by the absence of lead in the composition, but because the polarization retention, replacing PZT in FeRAM devices. The strontium bismuth tantalate (SrBi 2 Ta 2 O 9 ) or SBT is ferroelectric material that has attracted considerable interest, since it has high fatigue resistance, supporting high hysteresis loops, with the change in polarization.Checking polarization and depolarization currents stimulated by temperature it is possible to obtain, for example, information about the nature of charges and about the activation energy for the process of dielectric relaxation. For analysis of ferroelectric properties of this compound, it is essential to obtain specimens with a relative density around 95%. Thus, it is important the optimization of the sintering process in order to obtain a ceramic body with a high densification. The influence of sintering parameters to obtain SrBi 2 Ta 2 O 9 in the polarization properties and in the microstructure of sintered samples was investigated by thermostimulated currents and electronic microscopy, respectively. Results show that variation of these parameters may cause changes in the ferroelectric properties of the material. (author)

  4. Sampling intraspecific variability in leaf functional traits: Practical suggestions to maximize collected information.

    Science.gov (United States)

    Petruzzellis, Francesco; Palandrani, Chiara; Savi, Tadeja; Alberti, Roberto; Nardini, Andrea; Bacaro, Giovanni

    2017-12-01

    The choice of the best sampling strategy to capture mean values of functional traits for a species/population, while maintaining information about traits' variability and minimizing the sampling size and effort, is an open issue in functional trait ecology. Intraspecific variability (ITV) of functional traits strongly influences sampling size and effort. However, while adequate information is available about intraspecific variability between individuals (ITV BI ) and among populations (ITV POP ), relatively few studies have analyzed intraspecific variability within individuals (ITV WI ). Here, we provide an analysis of ITV WI of two foliar traits, namely specific leaf area (SLA) and osmotic potential (π), in a population of Quercus ilex L. We assessed the baseline ITV WI level of variation between the two traits and provided the minimum and optimal sampling size in order to take into account ITV WI , comparing sampling optimization outputs with those previously proposed in the literature. Different factors accounted for different amount of variance of the two traits. SLA variance was mostly spread within individuals (43.4% of the total variance), while π variance was mainly spread between individuals (43.2%). Strategies that did not account for all the canopy strata produced mean values not representative of the sampled population. The minimum size to adequately capture the studied functional traits corresponded to 5 leaves taken randomly from 5 individuals, while the most accurate and feasible sampling size was 4 leaves taken randomly from 10 individuals. We demonstrate that the spatial structure of the canopy could significantly affect traits variability. Moreover, different strategies for different traits could be implemented during sampling surveys. We partially confirm sampling sizes previously proposed in the recent literature and encourage future analysis involving different traits.

  5. Comparison between two sampling methods by results obtained using petrographic techniques, specially developed for minerals of the Itataia uranium phosphate deposit, Ceara, Brazil

    International Nuclear Information System (INIS)

    Salas, H.T.; Murta, R.L.L.

    1985-01-01

    The results of comparison of two sampling methods applied to a gallery of the uranium-phosphate ore body of Itataia-Ceara State, Brazil, along 235 metres of mineralized zone, are presented. The results were obtained through petrographic techniques especially developed and applied to both samplings. In the first one it was studied hand samples from a systematically sampling made at intervals of 2 metres. After that, the estimated mineralogical composition studies were carried out. Some petrogenetic observations were for the first time verified. The second sampling was made at intervals of 20 metres and 570 tons of ore extracted and distributed in sections and a sample representing each section was studied after crushing at -65. Their mineralogy were quantified and the degree of liberation of apatite calculated. Based on the mineralogical data obtained it was possible to represent both samplings and to make the comparison of the main mineralogical groups (phosphates, carbonates and silicates). In spite of utilizing different methods and methodology and the kind of mineralization, stockwork, being quite irregular, the results were satisfactory. (Author) [pt

  6. Functional patterns obtained by nanoimprinting lithography and subsequent growth of polymer brushes

    International Nuclear Information System (INIS)

    Genua, A; AlduncIn, J A; Pomposo, J A; Grande, H; Kehagias, N; Reboud, V; Sotomayor, C; Mondragon, I; Mecerreyes, D

    2007-01-01

    In this work the growth of polymer brushes was combined with nanoimprint lithography (NIL) in order to obtain new functional nanopatterns. First, a functional thermoplastic methacrylic copolymer poly(methyl methacrylate-co-2-bromoisobutyryl-oxy-ethyl methacrylate) was synthesized. This copolymer was successfully patterned by NIL using a silicon stamp at 160 deg. C and 60 bar. Next, hydrophilic polymer brushes based on poly(3-sulfopropylmethacrylate) and hydrophobic polymer brushes based on a poly(fluorinated methacrylate) were grown on the imprinted surfaces. The surface properties of the patterned polymer were accordingly modified and, as a consequence, the water contact angle was modified from 80.3 deg. to 32.5 deg. in the case of the hydrophilic brushes and to 118.1 deg. in the case of the hydrophobic brushes. As an application we demonstrated the use of hydrophobic polymer brushes in order to modify the surface of polymeric stamps for NIL with self-demoulding properties

  7. Performance of a Brazilian sample on the Portuguese translation of the BNI Screen for Higher Cerebral Functions.

    Science.gov (United States)

    Prigatano, George P; Souza, Lígia M N; Braga, Lucia W

    2018-03-01

    The Barrow Neurological Institute (BNI) Screen for Higher Cerebral Functions (BNIS) has been translated into several languages and found useful in evaluating multiple domains of cognitive and affective dysfunction, particularly in neuro-rehabilitation settings. Normative data from countries with high literacy rates have reported strikingly similar mean level of performance scores on this test, with age typically correlating higher with total score performance than education. In the present study, we obtain convenience sample normative data from a native Brazilian population on a Portuguese translation of the BNIS (i.e., BNIS-PT). The BNIS was translated into Portuguese by two native speaking Portuguese neuropsychologists who were also fluent in English. It was then administered to 201 normally functioning native Brazilian individuals who varied considerably in age and formal educational training. The mean BNIS total score was similar to what previous studies reported, but primarily in younger adults with at least 12 years of formal education. In this Brazilian sample, the correlation of educational level and BNIS total score was r = .68, p < .001. The correlation of age and BNIS total score was r = -.36, p < .001. This is the opposite pattern to that observed in previous standardization studies. The strong correlation of education with performance in various subtests was observed in all age groups (ages ranging from 15 to 85 years). This standardization study provides guidelines for calculating expected average performance levels on the BNIS-PT for Brazilian individuals with varying degrees of age and education. Educational level positively correlated with test performance on the BNIS-PT and was repeatedly observed to overshadow the effects of age, suggesting its important role in the development of higher cerebral functions in multiple domains in a Brazilian sample of normally functioning individuals.

  8. Quantum Numbers and the Eigenfunction Approach to Obtain Symmetry Adapted Functions for Discrete Symmetries

    Directory of Open Access Journals (Sweden)

    Renato Lemus

    2012-11-01

    Full Text Available The eigenfunction approach used for discrete symmetries is deduced from the concept of quantum numbers. We show that the irreducible representations (irreps associated with the eigenfunctions are indeed a shorthand notation for the set of eigenvalues of the class operators (character table. The need of a canonical chain of groups to establish a complete set of commuting operators is emphasized. This analysis allows us to establish in natural form the connection between the quantum numbers and the eigenfunction method proposed by J.Q. Chen to obtain symmetry adapted functions. We then proceed to present a friendly version of the eigenfunction method to project functions.

  9. Vibrational properties of gold nanoparticles obtained by green synthesis

    Science.gov (United States)

    Alvarez, Ramón A. B.; Cortez-Valadez, M.; Bueno, L. Oscar Neira; Britto Hurtado, R.; Rocha-Rocha, O.; Delgado-Beleño, Y.; Martinez-Nuñez, C. E.; Serrano-Corrales, Luis Ivan; Arizpe-Chávez, H.; Flores-Acosta, M.

    2016-10-01

    This study reports the synthesis and characterization of gold nanoparticles through an ecological method to obtain nanostructures from the extract of the plant Opuntia ficus-indica. Colloidal nanoparticles show sizes that vary between 10-20 nm, and present various geometric morphologies. The samples were characterized through optical absorption, Raman Spectroscopy and Transmission Electron Microscopy (TEM). Additionally, low energy metallic clusters of Aun (n=2-20 atoms) were modeled by computational quantum chemistry. The theoretical results were obtained with Density Functional Theory (DFT). The predicted results of Au clusters show a tendency and are correlated with the experimental results concerning the optical absorption bands and Raman spectroscopy in gold nanoparticles.

  10. Analytical dual-energy microtomography: A new method for obtaining three-dimensional mineral phase images and its application to Hayabusa samples

    Science.gov (United States)

    Tsuchiyama, A.; Nakano, T.; Uesugi, K.; Uesugi, M.; Takeuchi, A.; Suzuki, Y.; Noguchi, R.; Matsumoto, T.; Matsuno, J.; Nagano, T.; Imai, Y.; Nakamura, T.; Ogami, T.; Noguchi, T.; Abe, M.; Yada, T.; Fujimura, A.

    2013-09-01

    We developed a novel technique called "analytical dual-energy microtomography" that uses the linear attenuation coefficients (LACs) of minerals at two different X-ray energies to nondestructively obtain three-dimensional (3D) images of mineral distribution in materials such as rock specimens. The two energies are above and below the absorption edge energy of an abundant element, which we call the "index element". The chemical compositions of minerals forming solid solution series can also be measured. The optimal size of a sample is of the order of the inverse of the LAC values at the X-ray energies used. We used synchrotron-based microtomography with an effective spatial resolution of >200 nm to apply this method to small particles (30-180 μm) collected from the surface of asteroid 25143 Itokawa by the Hayabusa mission of the Japan Aerospace Exploration Agency (JAXA). A 3D distribution of the minerals was successively obtained by imaging the samples at X-ray energies of 7 and 8 keV, using Fe as the index element (the K-absorption edge of Fe is 7.11 keV). The optimal sample size in this case is of the order of 50 μm. The chemical compositions of the minerals, including the Fe/Mg ratios of ferromagnesian minerals and the Na/Ca ratios of plagioclase, were measured. This new method is potentially applicable to other small samples such as cosmic dust, lunar regolith, cometary dust (recovered by the Stardust mission of the National Aeronautics and Space Administration [NASA]), and samples from extraterrestrial bodies (those from future sample return missions such as the JAXA Hayabusa2 mission and the NASA OSIRIS-REx mission), although limitations exist for unequilibrated samples. Further, this technique is generally suited for studying materials in multicomponent systems with multiple phases across several research fields.

  11. Comparison of the diagnostic performance of bacterial culture of nasopharyngeal swab and bronchoalveolar lavage fluid samples obtained from calves with bovine respiratory disease.

    Science.gov (United States)

    Capik, Sarah F; White, Brad J; Lubbers, Brian V; Apley, Michael D; DeDonder, Keith D; Larson, Robert L; Harhay, Greg P; Chitko-McKown, Carol G; Harhay, Dayna M; Kalbfleisch, Ted S; Schuller, Gennie; Clawson, Michael L

    2017-03-01

    OBJECTIVE To compare predictive values, extent of agreement, and gamithromycin susceptibility between bacterial culture results of nasopharyngeal swab (NPS) and bronchoalveolar lavage fluid (BALF) samples obtained from calves with bovine respiratory disease (BRD). ANIMALS 28 beef calves with clinical BRD. PROCEDURES Pooled bilateral NPS samples and BALF samples were obtained for bacterial culture from calves immediately before and at various times during the 5 days after gamithromycin (6 mg/kg, SC, once) administration. For each culture-positive sample, up to 12 Mannheimia haemolytica, 6 Pasteurella multocida, and 6 Histophilus somni colonies underwent gamithromycin susceptibility testing. Whole-genome sequencing was performed on all M haemolytica isolates. For paired NPS and BALF samples collected 5 days after gamithromycin administration, the positive and negative predictive values for culture results of NPS samples relative to those of BALF samples and the extent of agreement between the sampling methods were determined. RESULTS Positive and negative predictive values of NPS samples were 67% and 100% for M haemolytica, 75% and 100% for P multocida, and 100% and 96% for H somni. Extent of agreement between results for NPS and BALF samples was substantial for M haemolytica (κ, 0.71) and H somni (κ, 0.78) and almost perfect for P multocida (κ, 0.81). Gamithromycin susceptibility varied within the same sample and between paired NPS and BALF samples. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated culture results of NPS and BALF samples from calves with BRD should be interpreted cautiously considering disease prevalence within the population, sample collection relative to antimicrobial administration, and limitations of diagnostic testing methods.

  12. Failure Probability Estimation Using Asymptotic Sampling and Its Dependence upon the Selected Sampling Scheme

    Directory of Open Access Journals (Sweden)

    Martinásková Magdalena

    2017-12-01

    Full Text Available The article examines the use of Asymptotic Sampling (AS for the estimation of failure probability. The AS algorithm requires samples of multidimensional Gaussian random vectors, which may be obtained by many alternative means that influence the performance of the AS method. Several reliability problems (test functions have been selected in order to test AS with various sampling schemes: (i Monte Carlo designs; (ii LHS designs optimized using the Periodic Audze-Eglājs (PAE criterion; (iii designs prepared using Sobol’ sequences. All results are compared with the exact failure probability value.

  13. A sampling approach to constructing Lyapunov functions for nonlinear continuous–time systems

    NARCIS (Netherlands)

    Bobiti, R.V.; Lazar, M.

    2016-01-01

    The problem of constructing a Lyapunov function for continuous-time nonlinear dynamical systems is tackled in this paper via a sampling-based approach. The main idea of the sampling-based method is to verify a Lyapunov-type inequality for a finite number of points (known state vectors) in the

  14. NaCl samples for optical luminescence dosimetry

    International Nuclear Information System (INIS)

    Catli, S.

    2005-01-01

    Optically stimulated luminescence (OSL) have been used broadly for luminescence dosimetry and dating. In many cases, it has been pointed out that the decay of the OSL do not generally behave according to a simple exponential function. In this study the Infra-red stimulated luminescence (IRSL) intensity from NaCl samples were experimentally measured. The decay curves for this sample were fitted to some functions and it is in good agreement with the function y = α + b exp(-cx). The IRSL decay curves from NaCl using different β-doses have been obtained and investigated their dose response

  15. Radiochemical data obtained by {alpha} spectrometry on unrecrystallized fossil coral samples from the Egyptian shoreline of the north-western Red Sea

    Energy Technology Data Exchange (ETDEWEB)

    Choukri, A. [Laboratoire de Physique de la Matiere et Rayonnement, Equipe de Physique et Techniques Nucleaires, UFR ' Faibles Radioactivites, Mathematiques physiques et environnement' Universite Ibn Tofail, Faculte des Sciences, Departement de Physique, P.B. 133, 14 000 Kenitra (Morocco)]. E-mail: choukrimajid@yahoo.com; Hakam, O.K. [Laboratoire de Physique de la Matiere et Rayonnement, Equipe de Physique et Techniques Nucleaires, UFR ' Faibles Radioactivites, Mathematiques physiques et environnement' Universite Ibn Tofail, Faculte des Sciences, Departement de Physique, P.B. 133, 14 000 Kenitra (Morocco); Reyss, J.L. [Laboratoire des Sciences de Climat et de l' Environnement, Domaine du CNRS, Avenue de la Terrasse 91 1958, Gif sur Yvette (France); Plaziat, J.C. [Universite de Paris-Sud, Departement des Sciences de la Terre, URA 723, Batiment 504, F-91405 Orsay, Cedex (France)

    2007-02-15

    In this work, radiochemical results obtained by {alpha} spectrometry on 80 unrecrystallized fossil coral samples from the Egyptian shoreline of the north-western Red Sea are presented and discussed. The coral samples were collected in Egypt from the emerged 5e coral reef terraces over 500km from The Ras Gharib-Ras Shukeir depression (28 deg. 10{sup '}) in the north to Wadi Lahami (north of Ras Banas, 24 deg. 10{sup '}) in the south. The statistical description of radiochemical results (concentrations of U and Th radioisotopes, {sup 234}U/{sup 238}U activity ratios and ages) obtained on a great number of coral samples showed that it is possible to establish methodological criterions which could be used to validate the measured ages before confronting them to the geological context of sampling sites. The obtained results confirm that the unrecrystallized corals ({sup 232}Th<3%) constitute the reliable means of determining the timing of Pleistocene sea-level fluctuations in the past. A few number of measured younger ages could be explain as a result of a rejuvenation due to latter addition of a ''younger'' uranium to the initial stock entered just after coral death. The obvious rejuvenation observed and confirmed is due to a recent cementation of aragonitic deposit on the fossil coral. {sup 238}U varies between 2.2 and 4.9ppm around an average of 3.18+/-0.65ppm. {sup 234}U/ {sup 238}U activity ratios are between 1.08 and 1.28 with an averaged value of 1.164+/-0.016 which exceeds that of present day sea water but which is in agreement with the ratio of 1.16 measured by a precise mass spectrometry in many Pleistocene coral samples. Except three samples dated at least 100ka, the radiochemical age of 5e coral samples vary between 108 and 131ka with an average value of 122.2ka and a standard deviation of 4.3ka. Except for samples from the Zeit area, the reef terrace is between 2 and 6m above the present sea level. This position is similar to

  16. Joint sampling programme-Verification of data obtained in environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lauria, D.C. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)], E-mail: dejanira@ird.gov.br; Martins, N.S.F.; Vasconcellos, M.L.H.; Zenaro, R.; Peres, S.S.; Pires do Rio, M.A. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)

    2008-11-15

    The objective of the Environmental Radiological Monitoring Control programme carried out by the Institute of Radiation Protection and Dosimetry (IRD) in Brazil is to verify the licensee's compliance with the requirements for environmental monitoring of Brazilian facilities. The Joint Sampling Programme (JSP) is just one part of the control programme. In order to verify that the data reported by the licensees is representative and legitimate, this programme verifies sampling procedures, accuracy and precision of the data and the changes in the environmental conditions. This paper discusses the main findings of this programme that allowed IRD to optimize its available resources to control the monitoring of the eight facilities in Brazil.

  17. Rational Arithmetic Mathematica Functions to Evaluate the Two-Sided One Sample K-S Cumulative Sampling Distribution

    Directory of Open Access Journals (Sweden)

    J. Randall Brown

    2007-06-01

    Full Text Available One of the most widely used goodness-of-fit tests is the two-sided one sample Kolmogorov-Smirnov (K-S test which has been implemented by many computer statistical software packages. To calculate a two-sided p value (evaluate the cumulative sampling distribution, these packages use various methods including recursion formulae, limiting distributions, and approximations of unknown accuracy developed over thirty years ago. Based on an extensive literature search for the two-sided one sample K-S test, this paper identifies an exact formula for sample sizes up to 31, six recursion formulae, and one matrix formula that can be used to calculate a p value. To ensure accurate calculation by avoiding catastrophic cancelation and eliminating rounding error, each of these formulae is implemented in rational arithmetic. For the six recursion formulae and the matrix formula, computational experience for sample sizes up to 500 shows that computational times are increasing functions of both the sample size and the number of digits in the numerator and denominator integers of the rational number test statistic. The computational times of the seven formulae vary immensely but the Durbin recursion formula is almost always the fastest. Linear search is used to calculate the inverse of the cumulative sampling distribution (find the confidence interval half-width and tables of calculated half-widths are presented for sample sizes up to 500. Using calculated half-widths as input, computational times for the fastest formula, the Durbin recursion formula, are given for sample sizes up to two thousand.

  18. Endometrial aspiration biopsy: a non-invasive method of obtaining functional lymphoid progenitor cells and mature natural killer cells.

    LENUS (Irish Health Repository)

    McMenamin, Moya

    2012-09-01

    The aim of this study was to compare the efficacy of endometrial aspiration biopsy (EAB) with the more traditional dilatation and curettage (D&C) for the procurement of lymphoid progenitor cells and uterine natural killer (NK) populations in endometrial tissue. This prospective observational study conducted in a tertiary referral university hospital examined endometrium obtained from 32 women admitted for laparoscopic gynaecological procedures. Each participant had endometrium sampled using both EAB and D&C. Both methods were assessed as a source of uterine NK and lymphoid progenitor cells. Similar proportions of mature CD45+CD56+ NK cells (range 25.4-36.2%) and CD45+CD34+ lymphoid progenitors (range 1.2-2.0%) were found in tissue obtained using both EAB and D&C. These cells were adequate for flow cytometric analysis, magnetic bead separation and culture. Colony formation by the CD34+ population demonstrated maturational potential. Tissues obtained via endometrial biopsy and D&C are equivalent, by analysis of uterine NK and lymphoid progenitor cells. The aim of this study was to compare two methods of endometrial sampling - endometrial aspiration biopsy and traditional dilatation and curettage - for the procurement of haematopoietic stem cells and uterine natural killer (NK) populations in endometrial tissue. Thirty-two women who had gynaecological procedures in a tertiary referral hospital participated in this study and had endometrial tissue collected via both methods. Similar populations of mature NK cells and haematopoietic stem cells were found in tissue obtained using both endometrial aspiration biopsy and dilatation and curettage. Tissue obtained via endometrial aspiration biopsy was adequate for the culture and growth of haematopoietic stem cells. We conclude that tissue obtained via endometrial biopsy and dilatation and curettage is equivalent, by analysis of uterine NK and haematopoietic stem cells using flow cytometry. This has implications for further

  19. Factors associated with number of duodenal samples obtained in suspected celiac disease.

    Science.gov (United States)

    Shamban, Leonid; Sorser, Serge; Naydin, Stan; Lebwohl, Benjamin; Shukr, Mousa; Wiemann, Charlotte; Yevsyukov, Daniel; Piper, Michael H; Warren, Bradley; Green, Peter H R

    2017-12-01

     Many people with celiac disease are undiagnosed and there is evidence that insufficient duodenal samples may contribute to underdiagnosis. The aims of this study were to investigate whether more samples leads to a greater likelihood of a diagnosis of celiac disease and to elucidate factors that influence the number of samples collected.  We identified patients from two community hospitals who were undergoing duodenal biopsy for indications (as identified by International Classification of Diseases code) compatible with possible celiac disease. Three cohorts were evaluated: no celiac disease (NCD, normal villi), celiac disease (villous atrophy, Marsh score 3), and possible celiac disease (PCD, Marsh score celiac disease had a median of 4 specimens collected. The percentage of patients diagnosed with celiac disease with one sample was 0.3 % compared with 12.8 % of those with six samples ( P  = 0.001). Patient factors that positively correlated with the number of samples collected were endoscopic features, demographic details, and indication ( P  = 0.001). Endoscopist factors that positively correlated with the number of samples collected were absence of a trainee, pediatric gastroenterologist, and outpatient setting ( P  celiac disease significantly increased with six samples. Multiple factors influenced whether adequate biopsies were taken. Adherence to guidelines may increase the diagnosis rate of celiac disease.

  20. Rietveld analysis using powder diffraction data with anomalous scattering effect obtained by focused beam flat sample method

    International Nuclear Information System (INIS)

    Tanaka, Masahiko; Katsuya, Yoshio; Sakata, Osami

    2016-01-01

    Focused-beam flat-sample method (FFM) is a new trial for synchrotron powder diffraction method, which is a combination of beam focusing optics, flat shape powder sample and area detectors. The method has advantages for X-ray diffraction experiments applying anomalous scattering effect (anomalous diffraction), because of 1. Absorption correction without approximation, 2. High intensity X-rays of focused incident beams and high signal noise ratio of diffracted X-rays 3. Rapid data collection with area detectors. We applied the FFM to anomalous diffraction experiments and collected synchrotron X-ray powder diffraction data of CoFe_2O_4 (inverse spinel structure) using X-rays near Fe K absorption edge, which can distinguish Co and Fe by anomalous scattering effect. We conducted Rietveld analyses with the obtained powder diffraction data and successfully determined the distribution of Co and Fe ions in CoFe_2O_4 crystal structure.

  1. Estimation of functional failure probability of passive systems based on adaptive importance sampling method

    International Nuclear Information System (INIS)

    Wang Baosheng; Wang Dongqing; Zhang Jianmin; Jiang Jing

    2012-01-01

    In order to estimate the functional failure probability of passive systems, an innovative adaptive importance sampling methodology is presented. In the proposed methodology, information of variables is extracted with some pre-sampling of points in the failure region. An important sampling density is then constructed from the sample distribution in the failure region. Taking the AP1000 passive residual heat removal system as an example, the uncertainties related to the model of a passive system and the numerical values of its input parameters are considered in this paper. And then the probability of functional failure is estimated with the combination of the response surface method and adaptive importance sampling method. The numerical results demonstrate the high computed efficiency and excellent computed accuracy of the methodology compared with traditional probability analysis methods. (authors)

  2. Estimation of Finite Population Mean in Multivariate Stratified Sampling under Cost Function Using Goal Programming

    Directory of Open Access Journals (Sweden)

    Atta Ullah

    2014-01-01

    Full Text Available In practical utilization of stratified random sampling scheme, the investigator meets a problem to select a sample that maximizes the precision of a finite population mean under cost constraint. An allocation of sample size becomes complicated when more than one characteristic is observed from each selected unit in a sample. In many real life situations, a linear cost function of a sample size nh is not a good approximation to actual cost of sample survey when traveling cost between selected units in a stratum is significant. In this paper, sample allocation problem in multivariate stratified random sampling with proposed cost function is formulated in integer nonlinear multiobjective mathematical programming. A solution procedure is proposed using extended lexicographic goal programming approach. A numerical example is presented to illustrate the computational details and to compare the efficiency of proposed compromise allocation.

  3. Rietveld analysis using powder diffraction data with anomalous scattering effect obtained by focused beam flat sample method

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Masahiko, E-mail: masahiko@spring8.or.jp; Katsuya, Yoshio, E-mail: katsuya@spring8.or.jp; Sakata, Osami, E-mail: SAKATA.Osami@nims.go.jp [Synchrotron X-ray Station at SPring-8, National Institute for Materials Science 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

    2016-07-27

    Focused-beam flat-sample method (FFM) is a new trial for synchrotron powder diffraction method, which is a combination of beam focusing optics, flat shape powder sample and area detectors. The method has advantages for X-ray diffraction experiments applying anomalous scattering effect (anomalous diffraction), because of 1. Absorption correction without approximation, 2. High intensity X-rays of focused incident beams and high signal noise ratio of diffracted X-rays 3. Rapid data collection with area detectors. We applied the FFM to anomalous diffraction experiments and collected synchrotron X-ray powder diffraction data of CoFe{sub 2}O{sub 4} (inverse spinel structure) using X-rays near Fe K absorption edge, which can distinguish Co and Fe by anomalous scattering effect. We conducted Rietveld analyses with the obtained powder diffraction data and successfully determined the distribution of Co and Fe ions in CoFe{sub 2}O{sub 4} crystal structure.

  4. Flow injection preconcentration system using a new functionalized resin for determination of cadmium and nickel in tobacco samples

    International Nuclear Information System (INIS)

    Lemos, Valfredo Azevedo; Novaes, Cleber Galvao; Lima, Adriana da Silva; Vieira, Daniel Rodrigues

    2008-01-01

    A solid-phase extraction method combined with flow injection (FI) on-line flame atomic absorption spectrometry (FAAS) for the determination of cadmium and nickel in tobacco samples is presented. The 2-aminothiophenol functionalized Amberlite XAD-4 (AT-XAD) resin was synthesized by covalent coupling of the ligand with the copolymer through a methylene group. A minicolumn packed with AT-XAD was connected into the automated on-line preconcentration system. Elution of metal ions from minicolumn can be made with 0.50 mol L -1 hydrochloric acid solution. With a consumption of 21.0 mL of sample solution, detection limits (3 s) of 0.3 (Cd) and 0.8 μg L -1 (Ni) were achieved at a sample throughput of 18 h -1 . Enrichment factors (EF) of 99 (cadmium) and 43 (nickel) were obtained compared with the slope of the linear portion of the calibration curves before and after preconcentration. The contents of Cd and Ni in a certified reference material (NIST 1570a, spinach leaves) determined by the present method was in good agreement with the certified value. The developed procedure was also successfully applied to the determination of Cd and Ni in local tobacco samples

  5. Obtaining of potassium dicyan-argentate

    International Nuclear Information System (INIS)

    Sattarova, M.A.; Solojenkin, P.M.

    1997-01-01

    This work is devoted to obtaining of potassium dicyan-argentate. By means of exchange reaction between silver nitrate and potassium cyanide the potassium dicyan-argentate was synthesized. The analysis of obtained samples was carried out by means of titration and potentiometry.

  6. Stable isotope analysis of precipitation samples obtained via crowdsourcing reveals the spatiotemporal evolution of Superstorm Sandy.

    Directory of Open Access Journals (Sweden)

    Stephen P Good

    Full Text Available Extra-tropical cyclones, such as 2012 Superstorm Sandy, pose a significant climatic threat to the northeastern United Sates, yet prediction of hydrologic and thermodynamic processes within such systems is complicated by their interaction with mid-latitude water patterns as they move poleward. Fortunately, the evolution of these systems is also recorded in the stable isotope ratios of storm-associated precipitation and water vapor, and isotopic analysis provides constraints on difficult-to-observe cyclone dynamics. During Superstorm Sandy, a unique crowdsourced approach enabled 685 precipitation samples to be obtained for oxygen and hydrogen isotopic analysis, constituting the largest isotopic sampling of a synoptic-scale system to date. Isotopically, these waters span an enormous range of values (> 21‰ for δ(18O, > 160‰ for δ(2H and exhibit strong spatiotemporal structure. Low isotope ratios occurred predominantly in the west and south quadrants of the storm, indicating robust isotopic distillation that tracked the intensity of the storm's warm core. Elevated values of deuterium-excess (> 25‰ were found primarily in the New England region after Sandy made landfall. Isotope mass balance calculations and Lagrangian back-trajectory analysis suggest that these samples reflect the moistening of dry continental air entrained from a mid-latitude trough. These results demonstrate the power of rapid-response isotope monitoring to elucidate the structure and dynamics of water cycling within synoptic-scale systems and improve our understanding of storm evolution, hydroclimatological impacts, and paleo-storm proxies.

  7. Stable isotope analysis of precipitation samples obtained via crowdsourcing reveals the spatiotemporal evolution of Superstorm Sandy.

    Science.gov (United States)

    Good, Stephen P; Mallia, Derek V; Lin, John C; Bowen, Gabriel J

    2014-01-01

    Extra-tropical cyclones, such as 2012 Superstorm Sandy, pose a significant climatic threat to the northeastern United Sates, yet prediction of hydrologic and thermodynamic processes within such systems is complicated by their interaction with mid-latitude water patterns as they move poleward. Fortunately, the evolution of these systems is also recorded in the stable isotope ratios of storm-associated precipitation and water vapor, and isotopic analysis provides constraints on difficult-to-observe cyclone dynamics. During Superstorm Sandy, a unique crowdsourced approach enabled 685 precipitation samples to be obtained for oxygen and hydrogen isotopic analysis, constituting the largest isotopic sampling of a synoptic-scale system to date. Isotopically, these waters span an enormous range of values (> 21‰ for δ(18)O, > 160‰ for δ(2)H) and exhibit strong spatiotemporal structure. Low isotope ratios occurred predominantly in the west and south quadrants of the storm, indicating robust isotopic distillation that tracked the intensity of the storm's warm core. Elevated values of deuterium-excess (> 25‰) were found primarily in the New England region after Sandy made landfall. Isotope mass balance calculations and Lagrangian back-trajectory analysis suggest that these samples reflect the moistening of dry continental air entrained from a mid-latitude trough. These results demonstrate the power of rapid-response isotope monitoring to elucidate the structure and dynamics of water cycling within synoptic-scale systems and improve our understanding of storm evolution, hydroclimatological impacts, and paleo-storm proxies.

  8. Evaluation of Functional Marrow Irradiation Based on Skeletal Marrow Composition Obtained Using Dual-Energy Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Magome, Taiki [Department of Radiological Sciences, Faculty of Health Sciences, Komazawa University, Tokyo (Japan); Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota (United States); Department of Radiology, The University of Tokyo Hospital, Tokyo (Japan); Froelich, Jerry [Department of Radiology, University of Minnesota, Minneapolis, Minnesota (United States); Takahashi, Yutaka [Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota (United States); Department of Radiation Oncology, Osaka University, Osaka (Japan); Arentsen, Luke [Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota (United States); Holtan, Shernan; Verneris, Michael R. [Blood and Marrow Transplant Program, University of Minnesota, Minneapolis, Minnesota (United States); Brown, Keenan [Mindways Software Inc, Austin, Texas (United States); Haga, Akihiro; Nakagawa, Keiichi [Department of Radiology, The University of Tokyo Hospital, Tokyo (Japan); Holter Chakrabarty, Jennifer L. [College of Medicine, Oklahoma Health Sciences Center, Oklahoma City, Oklahoma (United States); Giebel, Sebastian [Department of Bone Marrow Transplantation, Comprehensive Cancer Center M. Curie-Sklodowska Memorial Institute, Gliwice (Poland); Wong, Jeffrey [Department of Radiation Oncology, Beckman Research Institute, City of Hope, Duarte, California (United States); Dusenbery, Kathryn [Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota (United States); Storme, Guy [Department of Radiotherapy, Universitair Ziekenhuis Brussel, Brussels (Belgium); Hui, Susanta K., E-mail: shui@coh.org [Masonic Cancer Center, University of Minnesota, Minneapolis, Minnesota (United States); Department of Therapeutic Radiology, University of Minnesota, Minneapolis, Minnesota (United States); Department of Radiation Oncology, Beckman Research Institute, City of Hope, Duarte, California (United States)

    2016-11-01

    Purpose: To develop an imaging method to characterize and map marrow composition in the entire skeletal system, and to simulate differential targeted marrow irradiation based on marrow composition. Methods and Materials: Whole-body dual energy computed tomography (DECT) images of cadavers and leukemia patients were acquired, segmented to separate bone marrow components, namely, bone, red marrow (RM), and yellow marrow (YM). DECT-derived marrow fat fraction was validated using histology of lumbar vertebrae obtained from cadavers. The fractions of RM (RMF = RM/total marrow) and YMF were calculated in each skeletal region to assess the correlation of marrow composition with sites and ages. Treatment planning was simulated to target irradiation differentially at a higher dose (18 Gy) to either RM or YM and a lower dose (12 Gy) to the rest of the skeleton. Results: A significant correlation between fat fractions obtained from DECT and cadaver histology samples was observed (r=0.861, P<.0001, Pearson). The RMF decreased in the head, neck, and chest was significantly inversely correlated with age but did not show any significant age-related changes in the abdomen and pelvis regions. Conformity of radiation to targets (RM, YM) was significantly dependent on skeletal sites. The radiation exposure was significantly reduced (P<.05, t test) to organs at risk (OARs) in RM and YM irradiation compared with standard total marrow irradiation (TMI). Conclusions: Whole-body DECT offers a new imaging technique to visualize and measure skeletal-wide marrow composition. The DECT-based treatment planning offers volumetric and site-specific precise radiation dosimetry of RM and YM, which varies with aging. Our proposed method could be used as a functional compartment of TMI for further targeted radiation to specific bone marrow environment, dose escalation, reduction of doses to OARs, or a combination of these factors.

  9. Magnetorheological measurements with consideration for the internal magnetic field in samples

    Energy Technology Data Exchange (ETDEWEB)

    Kordonski, W; Gorodkin, S [QED Technologies International, 1040 University Ave., Rochester, NY 14607 (United States)], E-mail: kordonski@qedmrf.com

    2009-02-01

    The magnetically induced yield stress in a sample of suspension of magnetic particles is associated with formation of a field-oriented structure, the strength of which depends on the degree of particles magnetization. This factor is largely defined by the actual magnetic field strength in the sample. At the same time it is common practice to present and analyze magnetorheological characteristics as a function of the applied magnetic field. Uncertainty of an influence function in magnetorheology hampers interpretation of data obtained with different measurement configurations. It was shown in this paper that rheological response of magnetorheological fluid to the applied magnetic field is defined by the sample's actual (internal) magnetic field intensity, which, in turn, depends on sample geometry and field orientation all other factors being equal. Utilization of the sample's actual field as an influence function in magnetorheology allows proper interpretation of data obtained with different measuring system configurations. Optimization of the actual internal field is a promising approach in designing of energy efficient magnetorheological devices.

  10. ESTIMATION OF PARAMETERS AND RELIABILITY FUNCTION OF EXPONENTIATED EXPONENTIAL DISTRIBUTION: BAYESIAN APPROACH UNDER GENERAL ENTROPY LOSS FUNCTION

    Directory of Open Access Journals (Sweden)

    Sanjay Kumar Singh

    2011-06-01

    Full Text Available In this Paper we propose Bayes estimators of the parameters of Exponentiated Exponential distribution and Reliability functions under General Entropy loss function for Type II censored sample. The proposed estimators have been compared with the corresponding Bayes estimators obtained under Squared Error loss function and maximum likelihood estimators for their simulated risks (average loss over sample space.

  11. The quantitative regional cerebral blood flow measurement with autoradiography method using 123I-IMP SPECT. Evaluation of arterialized venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ohnishi, Takashi; Yano, Takao; Nakano, Shinichi; Jinnouchi, Seishi; Nagamachi, Shigeki; Flores, L. II; Nakahara, Hiroshi; Watanabe, Katsushi.

    1996-01-01

    The purpose of this study is validation of calibrating a standard input function in autoradiography (ARG) method by one point venous blood sampling as a substitute for that by one point arterial blood sampling. Ten and 20 minutes after intravenous constant infusion of 123 I-IMP, arterialized venous blood sampling from a dorsal vein were performed on 15 patients having ischemic cerebrovascular disease. And arterial blood sampling from radial artery was performed 10 min after 123 I-IMP infusion. The mean difference rates of integrated input function between calibrated standard input function by arterial blood sampling at 10 min and that by venous blood sampling were 4.1±3% and 9.3±5.4% at 10 and 20 min after 123 I-IMP infusion, respectively. The ratio of venous blood radioactivity to arterial blood radioactivity at 10 min after 123 I-IMP infusion was 0.96±0.02. There was an excellent correlation between ARG method CBF values obtained by arterial blood sampling at 10 min and those obtained by arterialized venous blood sampling at 10 min. In conclusion, a substitution by arterialized venous blood sampling from dorsal hand vein for artery can be possible. The optimized time for arterialized venous blood sampling was 10 min after 123 I-IMP infusion. (author)

  12. Modulation transfer function cascade model for a sampled IR imaging system.

    Science.gov (United States)

    de Luca, L; Cardone, G

    1991-05-01

    The performance of the infrared scanning radiometer (IRSR) is strongly stressed in convective heat transfer applications where high spatial frequencies in the signal that describes the thermal image are present. The need to characterize more deeply the system spatial resolution has led to the formulation of a cascade model for the evaluation of the actual modulation transfer function of a sampled IR imaging system. The model can yield both the aliasing band and the averaged modulation response for a general sampling subsystem. For a line scan imaging system, which is the case of a typical IRSR, a rule of thumb that states whether the combined sampling-imaging system is either imaging-dependent or sampling-dependent is proposed. The model is tested by comparing it with other noncascade models as well as by ad hoc measurements performed on a commercial digitized IRSR.

  13. A new numerical method for inverse Laplace transforms used to obtain gluon distributions from the proton structure function

    International Nuclear Information System (INIS)

    Block, Martin M.; Durand, Loyal

    2011-01-01

    We recently derived a very accurate and fast new algorithm for numerically inverting the Laplace transforms needed to obtain gluon distributions from the proton structure function F 2 γp (x,Q 2 ). We numerically inverted the function g(s), s being the variable in Laplace space, to G(v), where v is the variable in ordinary space. We have since discovered that the algorithm does not work if g(s)→0 less rapidly than 1/s as s→∞, e.g., as 1/s β for 0 β-1 and a polynomial in v. We test the algorithm numerically for very small positive β, β=10 -6 obtaining numerical results that imitate the Dirac delta function δ(v). We also devolve the published MSTW2008LO gluon distribution at virtuality Q 2 =5 GeV 2 down to the lower virtuality Q 2 =1.69 GeV 2 . For devolution, β is negative, giving rise to inverse Laplace transforms that are distributions and not proper functions. This requires us to introduce the concept of Hadamard Finite Part integrals, which we discuss in detail. (orig.)

  14. Monte Carlo parametric importance sampling with particle tracks scaling

    International Nuclear Information System (INIS)

    Ragheb, M.M.H.

    1981-01-01

    A method for Monte Carlo importance sampling with parametric dependence is proposed. It depends upon obtaining over a single stage the overall functional dependence of the variance on the importance function parameter over a broad range of its values. Results corresponding to minimum variance are adopted and others rejected. The proposed method is applied to the finite slab penetration problem. When the exponential transformation is used, our method involves scaling of the generated particle tracks, and is a new application of Morton's method of similar trajectories. The method constitutes a generalization of Spanier's multistage importance sampling method, obtained by proper weighting over a single stage the curves he obtains over several stages, and preserves the statistical correlations between histories. It represents an extension of a theory by Frolov and Chentsov on Monte Carlo calculations of smooth curves to surfaces and to importance sampling calculations. By the proposed method, it seems possible to systematically arrive at minimum variance results and to avoid the infinite variances and effective biases sometimes observed in this type of calculation. (orig.) [de

  15. A Bone Sample Containing a Bone Graft Substitute Analyzed by Correlating Density Information Obtained by X-ray Micro Tomography with Compositional Information Obtained by Raman Microscopy

    Directory of Open Access Journals (Sweden)

    Johann Charwat-Pessler

    2015-06-01

    Full Text Available The ability of bone graft substitutes to promote new bone formation has been increasingly used in the medical field to repair skeletal defects or to replace missing bone in a broad range of applications in dentistry and orthopedics. A common way to assess such materials is via micro computed tomography (µ-CT, through the density information content provided by the absorption of X-rays. Information on the chemical composition of a material can be obtained via Raman spectroscopy. By investigating a bone sample from miniature pigs containing the bone graft substitute Bio Oss®, we pursued the target of assessing to what extent the density information gained by µ-CT imaging matches the chemical information content provided by Raman spectroscopic imaging. Raman images and Raman correlation maps of the investigated sample were used in order to generate a Raman based segmented image by means of an agglomerative, hierarchical cluster analysis. The resulting segments, showing chemically related areas, were subsequently compared with the µ-CT image by means of a one-way ANOVA. We found out that to a certain extent typical gray-level values (and the related histograms in the µ-CT image can be reliably related to specific segments within the image resulting from the cluster analysis.

  16. Reciprocal expansion of modified Bessel function in simple fractions and obtaining general summation relationships containing its zeros

    Science.gov (United States)

    Sherstyukov, V. B.; Sumin, E. V.

    2017-12-01

    Modified Bessel functions of the first kind Iv (z) (Infeld functions) where v > -1 are considered. Due to the constraint on the parameter v, all zeros of the function Iv (z) except z = 0 are simple, located on the imaginary axis by symmetric pairs and form an infinite countable set. On the basis on previous research of the authors dealing with general Bessel functions of the first kind Jv (z), a question about reciprocal expansion 1/Iv (z) in series of simple fractions of a certain structure (Krein’s series) is studied. The general formulas to calculate of special infinite sums containing degrees of Infeld function zeros are an important consequence of obtained expansion in simple fractions of the value 1/Iv (z) with any v > -1. The possibility of concrete definition of established summation relationships at different values of parameters and their connection with analogous relationships for the Bessel functions of the first kind Jv (z) is discussed.

  17. Addressing the challenges of obtaining functional outcomes in traumatic brain injury research: missing data patterns, timing of follow-up, and three prognostic models.

    Science.gov (United States)

    Zelnick, Leila R; Morrison, Laurie J; Devlin, Sean M; Bulger, Eileen M; Brasel, Karen J; Sheehan, Kellie; Minei, Joseph P; Kerby, Jeffrey D; Tisherman, Samuel A; Rizoli, Sandro; Karmy-Jones, Riyad; van Heest, Rardi; Newgard, Craig D

    2014-06-01

    Traumatic brain injury (TBI) is common and debilitating. Randomized trials of interventions for TBI ideally assess effectiveness by using long-term functional neurological outcomes, but such outcomes are difficult to obtain and costly. If there is little change between functional status at hospital discharge versus 6 months, then shorter-term outcomes may be adequate for use in future clinical trials. Using data from a previously published multi-center, randomized, placebo-controlled TBI clinical trial, we evaluated patterns of missing outcome data, changes in functional status between hospital discharge and 6 months, and three prognostic models to predict long-term functional outcome from covariates available at hospital discharge (functional measures, demographics, and injury characteristics). The Resuscitation Outcomes Consortium Hypertonic Saline trial enrolled 1282 TBI patients, obtaining the primary outcome of 6-month Glasgow Outcome Score Extended (GOSE) for 85% of patients, but missing the primary outcome for the remaining 15%. Patients with missing outcomes had less-severe injuries, higher neurological function at discharge (GOSE), and shorter hospital stays than patients whose GOSE was obtained. Of 1066 (83%) patients whose GOSE was obtained both at hospital discharge and at 6-months, 71% of patients had the same dichotomized functional status (severe disability/death vs. moderate/no disability) after 6 months as at discharge, 28% had an improved functional status, and 1% had worsened. Performance was excellent (C-statistic between 0.88 and 0.91) for all three prognostic models and calibration adequate for two models (p values, 0.22 and 0.85). Our results suggest that multiple imputation of the standard 6-month GOSE may be reasonable in TBI research when the primary outcome cannot be obtained through other means.

  18. Flame Atomic Absorption Determination of Gold Ion in Aqueous Samples after Preconcentration Using 9-Acridinylamine Functionalized γ-Alumina Nanoparticles

    Directory of Open Access Journals (Sweden)

    Mohammad Karimi

    2013-01-01

    Full Text Available A simple and sensitive solid phase extraction utilizing 9-acridinylamine functionalized alumina nanoparticles was developed, and their potential use for preconcentration and subsequent determination of gold by flame atomic absorption spectrometry (FAAS was investigated. A number of parameters, namely, type, concentration, and volume of eluent, pH of the sample solution, flow rate of extraction, and volume of the sample, were evaluated. The effect of a variety of ions on preconcentration and recovery was also investigated. Gold ions were found to be recovered quantitatively at pH 3.0, with 0.1 mol L−1 thiourea in 2 mol L−1 H2SO4 as eluent. The limit of detection (LOD, defined as five times the standard deviation of the blank, was determined to be lower than 13.0 ppb. Under optimum conditions, the accuracy and precision (RSD% of the method were >98.0 and <1.5%, respectively. To gauge its ability in terms of application to real samples, the proposed method was successfully applied for determination of gold concentration in waste water samples and one soil standard material, and satisfactory results were obtained.

  19. Carboxylic acid-functionalized SBA-15 nanorods for gemcitabine delivery

    International Nuclear Information System (INIS)

    Bahrami, Zohreh; Badiei, Alireza; Ziarani, Ghodsi Mohammadi

    2015-01-01

    The present study deals with the functionalization of mesoporous silica nanoparticles as drug delivery systems. Mono, di, and tri amino-functionalized SBA-15 nanorods were synthesized by post-grafting method using (3-aminopropyl) triethoxysilane, N-(2-aminoethyl-)3- aminopropyltrimethoxysilane, and 3-[2-(2-aminoethylamino) ethylamino] propyl trimethoxysilane, respectively. The carboxylic acid derivatives of the amino-functionalized samples were obtained using succinic anhydride. Tminopropyltrimethoxysilanehe obtained modified materials were investigated as matrixes for the anticancer drug (gemcitabine) delivery. The prepared samples were characterized by SAXS, N 2 adsorption/desorption, SEM, transmission electron microscopy, thermogravimetric analysis, and FTIR and UV spectroscopies. The adsorption and release properties of all samples were studied. It was revealed that the adsorption capacity and release behavior of gemcitabine were highly dependent on the type of the introduced functional groups. The carboxylic acid-modified samples have higher loading content, due to the strong interaction with gemcitabine. The maximum content of deposited drug in the modified SBA-15 nanorods is close to 40 wt%. It was found that the surface functionalization leads toward significant decrease of the drug release rate. The carboxylic acid-functionalized samples have slower release rate in contrast with the amino-functionalized samples

  20. Statistical evaluation of fatty acid profile and cholesterol content in fish (common carp) lipids obtained by different sample preparation procedures.

    Science.gov (United States)

    Spiric, Aurelija; Trbovic, Dejana; Vranic, Danijela; Djinovic, Jasna; Petronijevic, Radivoj; Matekalo-Sverak, Vesna

    2010-07-05

    the second principal component (PC2) is recorded by C18:3 n-3, and C20:3 n-6, being present in a higher amount in the samples treated by the modified Soxhlet extraction, while C22:5 n-3, C20:3 n-3, C22:1 and C20:4, C16 and C18 negatively influence the score values of the PC2, showing significantly increased level in the samples treated by ASE method. Hotelling's paired T-square test used on the first three principal components for confirmation of differences in individual fatty acid content obtained by ASE and Soxhlet method in carp muscle showed statistically significant difference between these two data sets (T(2)=161.308, p<0.001). Copyright 2010 Elsevier B.V. All rights reserved.

  1. A new numerical method for inverse Laplace transforms used to obtain gluon distributions from the proton structure function

    Energy Technology Data Exchange (ETDEWEB)

    Block, Martin M. [Northwestern University, Department of Physics and Astronomy, Evanston, IL (United States); Durand, Loyal [University of Wisconsin, Department of Physics, Madison, WI (United States)

    2011-11-15

    We recently derived a very accurate and fast new algorithm for numerically inverting the Laplace transforms needed to obtain gluon distributions from the proton structure function F{sub 2}{sup {gamma}}{sup p}(x,Q{sup 2}). We numerically inverted the function g(s), s being the variable in Laplace space, to G(v), where v is the variable in ordinary space. We have since discovered that the algorithm does not work if g(s){yields}0 less rapidly than 1/s as s{yields}{infinity}, e.g., as 1/s{sup {beta}} for 0 <{beta}<1. In this note, we derive a new numerical algorithm for such cases, which holds for all positive and non-integer negative values of {beta}. The new algorithm is exact if the original function G(v) is given by the product of a power v{sup {beta}}{sup -1} and a polynomial in v. We test the algorithm numerically for very small positive {beta}, {beta}=10{sup -6} obtaining numerical results that imitate the Dirac delta function {delta}(v). We also devolve the published MSTW2008LO gluon distribution at virtuality Q{sup 2}=5 GeV{sup 2} down to the lower virtuality Q{sup 2}=1.69 GeV{sup 2}. For devolution, {beta} is negative, giving rise to inverse Laplace transforms that are distributions and not proper functions. This requires us to introduce the concept of Hadamard Finite Part integrals, which we discuss in detail. (orig.)

  2. Value management : functional expression of the need and functional performance specification : requirements for expressing and validating the need to be satisfied within the process of purchasing or obtaining a product

    CERN Document Server

    Association Française de Normalisation. Paris

    2013-01-01

    Value management : functional expression of the need and functional performance specification : requirements for expressing and validating the need to be satisfied within the process of purchasing or obtaining a product

  3. Quantification of regional cerebral blood flow (rCBF) measurement with one point sampling by sup 123 I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Munaka, Masahiro [University of Occupational and Enviromental Health, Kitakyushu (Japan); Iida, Hidehiro; Murakami, Matsutaro

    1992-02-01

    A handy method of quantifying regional cerebral blood flow (rCBF) measurement by {sup 123}I-IMP SPECT was designed. A standard input function was made and the sampling time to calibrate this standard input function by one point sampling was optimized. An average standard input function was obtained from continuous arterial samplings of 12 healthy adults. The best sampling time was the minimum differential value between the integral calculus value of the standard input function calibrated by one point sampling and the input funciton by continuous arterial samplings. This time was 8 minutes after an intravenous injection of {sup 123}I-IMP and an error was estimated to be {+-}4.1%. The rCBF values by this method were evaluated by comparing them with the rCBF values of the input function with continuous arterial samplings in 2 healthy adults and a patient with cerebral infarction. A significant correlation (r=0.764, p<0.001) was obtained between both. (author).

  4. Transfer function design based on user selected samples for intuitive multivariate volume exploration

    KAUST Repository

    Zhou, Liang

    2013-02-01

    Multivariate volumetric datasets are important to both science and medicine. We propose a transfer function (TF) design approach based on user selected samples in the spatial domain to make multivariate volumetric data visualization more accessible for domain users. Specifically, the user starts the visualization by probing features of interest on slices and the data values are instantly queried by user selection. The queried sample values are then used to automatically and robustly generate high dimensional transfer functions (HDTFs) via kernel density estimation (KDE). Alternatively, 2D Gaussian TFs can be automatically generated in the dimensionality reduced space using these samples. With the extracted features rendered in the volume rendering view, the user can further refine these features using segmentation brushes. Interactivity is achieved in our system and different views are tightly linked. Use cases show that our system has been successfully applied for simulation and complicated seismic data sets. © 2013 IEEE.

  5. Transfer function design based on user selected samples for intuitive multivariate volume exploration

    KAUST Repository

    Zhou, Liang; Hansen, Charles

    2013-01-01

    Multivariate volumetric datasets are important to both science and medicine. We propose a transfer function (TF) design approach based on user selected samples in the spatial domain to make multivariate volumetric data visualization more accessible for domain users. Specifically, the user starts the visualization by probing features of interest on slices and the data values are instantly queried by user selection. The queried sample values are then used to automatically and robustly generate high dimensional transfer functions (HDTFs) via kernel density estimation (KDE). Alternatively, 2D Gaussian TFs can be automatically generated in the dimensionality reduced space using these samples. With the extracted features rendered in the volume rendering view, the user can further refine these features using segmentation brushes. Interactivity is achieved in our system and different views are tightly linked. Use cases show that our system has been successfully applied for simulation and complicated seismic data sets. © 2013 IEEE.

  6. An Optimization Study on Listening Experiments to Improve the Comparability of Annoyance Ratings of Noise Samples from Different Experimental Sample Sets.

    Science.gov (United States)

    Di, Guoqing; Lu, Kuanguang; Shi, Xiaofan

    2018-03-08

    Annoyance ratings obtained from listening experiments are widely used in studies on health effect of environmental noise. In listening experiments, participants usually give the annoyance rating of each noise sample according to its relative annoyance degree among all samples in the experimental sample set if there are no reference sound samples, which leads to poor comparability between experimental results obtained from different experimental sample sets. To solve this problem, this study proposed to add several pink noise samples with certain loudness levels into experimental sample sets as reference sound samples. On this basis, the standard curve between logarithmic mean annoyance and loudness level of pink noise was used to calibrate the experimental results and the calibration procedures were described in detail. Furthermore, as a case study, six different types of noise sample sets were selected to conduct listening experiments using this method to examine the applicability of it. Results showed that the differences in the annoyance ratings of each identical noise sample from different experimental sample sets were markedly decreased after calibration. The determination coefficient ( R ²) of linear fitting functions between psychoacoustic annoyance (PA) and mean annoyance (MA) of noise samples from different experimental sample sets increased obviously after calibration. The case study indicated that the method above is applicable to calibrating annoyance ratings obtained from different types of noise sample sets. After calibration, the comparability of annoyance ratings of noise samples from different experimental sample sets can be distinctly improved.

  7. USAXS and SAXS from cancer-bearing breast tissue samples

    International Nuclear Information System (INIS)

    Fernandez, M.; Suhonen, H.; Keyrilaeinen, J.; Bravin, A.; Fiedler, S.; Karjalainen-Lindsberg, M.-L.; Leidenius, M.; Smitten, K. von; Suortti, P.

    2008-01-01

    USAXS and SAXS patterns from cancer-bearing human breast tissue samples were recorded at beamline ID02 of the ESRF using a Bonse-Hart camera and a pinhole camera. The samples were classified as being ductal carcinoma, grade II, and ductal carcinoma in situ, partly invasive. The samples included areas of healthy collagen, invaded collagen, necrotic ducts with calcifications, and adipose tissue. The scattering patterns were analyzed in different ways to separate the scattering contribution and the direct beam from the observed rocking curve (RC) of the analyzer. It was found that USAXS from all tissues was weak, and the effects on the analyzer RC were observed only in the low-intensity tails of the patterns. The intrinsic RC was convolved with different model functions for the impulse response of the sample, and the best fit with experiment was obtained by the Pearson VII function. Significantly different distributions for the Pearson exponent m were obtained in benign and malignant regions of the samples. For a comparison with analyzer-based imaging (ABI) or diffraction enhanced imaging (DEI) a 'long-slit' integration of the patterns was performed, and this emphasized the scattering contribution in the tails of the rocking curve

  8. Direct sampling methods for inverse elastic scattering problems

    Science.gov (United States)

    Ji, Xia; Liu, Xiaodong; Xi, Yingxia

    2018-03-01

    We consider the inverse elastic scattering of incident plane compressional and shear waves from the knowledge of the far field patterns. Specifically, three direct sampling methods for location and shape reconstruction are proposed using the different component of the far field patterns. Only inner products are involved in the computation, thus the novel sampling methods are very simple and fast to be implemented. With the help of the factorization of the far field operator, we give a lower bound of the proposed indicator functionals for sampling points inside the scatterers. While for the sampling points outside the scatterers, we show that the indicator functionals decay like the Bessel functions as the sampling point goes away from the boundary of the scatterers. We also show that the proposed indicator functionals continuously dependent on the far field patterns, which further implies that the novel sampling methods are extremely stable with respect to data error. For the case when the observation directions are restricted into the limited aperture, we firstly introduce some data retrieval techniques to obtain those data that can not be measured directly and then use the proposed direct sampling methods for location and shape reconstructions. Finally, some numerical simulations in two dimensions are conducted with noisy data, and the results further verify the effectiveness and robustness of the proposed sampling methods, even for multiple multiscale cases and limited-aperture problems.

  9. Comparison of geochemical data obtained using four brine sampling methods at the SECARB Phase III Anthropogenic Test CO2 injection site, Citronelle Oil Field, Alabama

    Science.gov (United States)

    Conaway, Christopher; Thordsen, James J.; Manning, Michael A.; Cook, Paul J.; Trautz, Robert C.; Thomas, Burt; Kharaka, Yousif K.

    2016-01-01

    The chemical composition of formation water and associated gases from the lower Cretaceous Paluxy Formation was determined using four different sampling methods at a characterization well in the Citronelle Oil Field, Alabama, as part of the Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III Anthropogenic Test, which is an integrated carbon capture and storage project. In this study, formation water and gas samples were obtained from well D-9-8 #2 at Citronelle using gas lift, electric submersible pump, U-tube, and a downhole vacuum sampler (VS) and subjected to both field and laboratory analyses. Field chemical analyses included electrical conductivity, dissolved sulfide concentration, alkalinity, and pH; laboratory analyses included major, minor and trace elements, dissolved carbon, volatile fatty acids, free and dissolved gas species. The formation water obtained from this well is a Na–Ca–Cl-type brine with a salinity of about 200,000 mg/L total dissolved solids. Differences were evident between sampling methodologies, particularly in pH, Fe and alkalinity. There was little gas in samples, and gas composition results were strongly influenced by sampling methods. The results of the comparison demonstrate the difficulty and importance of preserving volatile analytes in samples, with the VS and U-tube system performing most favorably in this aspect.

  10. Bioanalysis of a panel of neurotransmitters and their metabolites in plasma samples obtained from pediatric patients with neuroblastoma and Wilms' tumor.

    Science.gov (United States)

    Konieczna, Lucyna; Roszkowska, Anna; Stachowicz-Stencel, Teresa; Synakiewicz, Anna; Bączek, Tomasz

    2018-02-01

    This paper details the quantitative analysis of neurotransmitters, including dopamine (DA), norepinephrine (NE), epinephrine (E), and serotonin (5-HT), along with their respective precursors and metabolites in children with solid tumors: Wilms' tumor (WT) and neuroblastoma (NB). A panel of neurotransmitters was determined with the use of dispersive liquid-liquid microextraction (DLLME) technique combined with liquid-chromatography mass spectrometry (LC-MS/MS) in plasma samples obtained from a group of pediatric subjects with solid tumors and a control group of healthy children. Next, statistical univariate analysis (t-test) and multivariate analysis (Principal Component Analysis) were performed using chromatographic data. The levels of tyrosine (Tyr) and tryptophan (Trp) (the precursors of analyzed neurotransmitters) as well as 3,4-dihydroxyphenylacetic acid (DOPAC) (a product of metabolism of DA) were significantly higher in the plasma samples obtained from pediatric patients with WT than in the samples taken from the control group. Moreover, statistically significant differences were observed between the levels of 5-HT and homovanillic acid (HVA) in the plasma samples from pediatric patients with solid tumors and the control group. However, elevated levels of these analytes did not facilitate a clear distinction between pediatric patients with WT and those with NB. Nonetheless, the application of advanced statistical tools allowed the healthy controls to be differentiated from the pediatric oncological patients. The identification and quantification of a panel of neurotransmitters as potential prognostic factors in selected childhood malignancies may provide clinically relevant information about ongoing metabolic alterations, and it could potentially serve as an adjunctive strategy in the effective diagnosis and treatment of solid tumors in children. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Expression of Biglycan in First Trimester Chorionic Villous Sampling Placental Samples and Altered Function in Telomerase-Immortalized Microvascular Endothelial Cells

    NARCIS (Netherlands)

    Chui, Amy; Gunatillake, Tilini; Brennecke, Shaun P.; Ignjatovic, Vera; Monagle, Paul T.; Whitelock, John M.; van Zanten, Dagmar E.; Eijsink, Jasper; Wang, Yao; Deane, James; Borg, Anthony J.; Stevenson, Janet; Erwich, Jan Jaap; Said, Joanne M.; Murthi, Padma

    Objective-Biglycan (BGN) has reduced expression in placentae from pregnancies complicated by fetal growth restriction (FGR). We used first trimester placental samples from pregnancies with later small for gestational age (SGA) infants as a surrogate for FGR. The functional consequences of reduced

  12. Radiopharmaceuticals: nanoparticles like multi-functional systems for the obtaining in vivo of molecular images

    International Nuclear Information System (INIS)

    Ferro F, G.; Ramirez de la Cruz, F. M.; Ocampo G, B. E.; Morales A, E.; Santos C, C. L.; Mendoza S, A. N.

    2010-01-01

    The techniques of obtaining direct or indirect molecular images detect and register the space-temporary distribution of molecular or cellular processes for biochemical, biological, diagnostic and therapeutic applications. The advanced techniques of image like the nuclear magnetic resonance, the single photon emission computed tomography, the positron emission tomography and the images of optic fluorescence have been used successfully to detect these processes. On the other hand, the utility of the nanoparticles for any application is dependent of the physicochemical properties that present, being possible to modify their surface when making them react with different biomolecules what allows the formation of conjugates with specific molecular recognition. The joint of various protein molecules, peptides or oligonucleotides to the surface of a nanoparticle produce a multi-functional system able to increase the multivalent joints from the nanoparticles-biomolecules to their receivers for the obtaining of molecular images in vivo. The peptides stimulate, regulate or inhibit numerous functions of the life, acting mainly as information transmitters and activity coordinators of several tissues in the organism. The receivers of regulator peptides are over represented in numerous types of cancer cells and they are protein structures. These receivers have been used as white molecular of marked peptides, to locate primary malignant tumors and their metastasis, using the diagnostic techniques of molecular image mentioned above, which consist basically on the radio peptides use and conjugated peptides to fluoro chromes, to metallic nanoparticles and nano crystals. A summary of the work is presented carried out by the personnel of the Radio-active Materials and Chemistry Departments of the Instituto Nacional de Investigaciones Nucleares in this field. (Author)

  13. Correlation of lithium levels between drinking water obtained from different sources and scalp hair samples of adult male subjects.

    Science.gov (United States)

    Baloch, Shahnawaz; Kazi, Tasneem Gul; Afridi, Hassan Imran; Baig, Jameel Ahmed; Talpur, Farah Naz; Arain, Muhammad Balal

    2017-10-01

    There is some evidence that natural levels of lithium (Li) in drinking water may have a protective effect on neurological health. In present study, we evaluate the Li levels in drinking water of different origin and bottled mineral water. To evaluate the association between lithium levels in drinking water with human health, the scalp hair samples of male subjects (25-45 years) consumed drinking water obtained from ground water (GW), municipal treated water (MTW) and bottled mineral water (BMW) from rural and urban areas of Sindh, Pakistan were selected. The water samples were pre-concentrated five to tenfold at 60 °C using temperature-controlled electric hot plate. While scalp hair samples were oxidized by acid in a microwave oven, prior to determined by flame atomic absorption spectrometry. The Li content in different types of drinking water, GW, MTW and BMW was found in the range of 5.12-22.6, 4.2-16.7 and 0.0-16.3 µg/L, respectively. It was observed that Li concentration in the scalp hair samples of adult males consuming ground water was found to be higher, ranged as 292-393 μg/kg, than those who are drinking municipal treated and bottle mineral water (212-268 and 145-208 μg/kg), respectively.

  14. Large-scale prospective T cell function assays in shipped, unfrozen blood samples

    DEFF Research Database (Denmark)

    Hadley, David; Cheung, Roy K; Becker, Dorothy J

    2014-01-01

    , for measuring core T cell functions. The Trial to Reduce Insulin-dependent diabetes mellitus in the Genetically at Risk (TRIGR) type 1 diabetes prevention trial used consecutive measurements of T cell proliferative responses in prospectively collected fresh heparinized blood samples shipped by courier within...... cell immunocompetence. We have found that the vast majority of the samples were viable up to 3 days from the blood draw, yet meaningful responses were found in a proportion of those with longer travel times. Furthermore, the shipping time of uncooled samples significantly decreased both the viabilities...... North America. In this article, we report on the quality control implications of this simple and pragmatic shipping practice and the interpretation of positive- and negative-control analytes in our assay. We used polyclonal and postvaccination responses in 4,919 samples to analyze the development of T...

  15. Prenatal cytogenetic diagnosis in Spain: analysis and evaluation of the results obtained from amniotic fluid samples during the last decade.

    Science.gov (United States)

    Mademont-Soler, Irene; Morales, Carme; Clusellas, Núria; Soler, Anna; Sánchez, Aurora

    2011-08-01

    Chromosome abnormalities are one of the main causes of congenital defects, and establishing their frequency according to the different clinical indications for invasive procedure during pregnancy is especially important for genetic counselling. We analyzed the results of 29,883 amniotic fluid samples referred to our laboratory for cytogenetic studies from 1998 to 2009, which constitutes the largest series of cytogenetic analysis performed on amniotic fluid samples in Spain. The number of samples received tended to increase from 1998 to 2005, but after 2005 it decreased substantially. Cytogenetic results were obtained in 99.5% of the samples, and the detected incidence of chromosome abnormalities was 2.9%. Of these, 48.1% consisted of classical autosomal aneuploidies, trisomy 21 being the most frequent one. The main clinical indications for amniocentesis were positive prenatal screening and advanced maternal age, but referral reasons with highest positive predictive values were, excluding parental chromosome rearrangement, increased nuchal translucency (9.2%) and ultrasound abnormalities (6.6%). In conclusion, performing the karyotype on amniotic fluid samples is a good method for the detection of chromosome abnormalities during pregnancy. The number of cytogenetic studies on amniotic fluid has now decreased, however, due to the implementation of first trimester prenatal screening for the detection of Down syndrome, which allows karyotyping on chorionic villus samples. Our results also show that both ultrasound abnormalities and increased nuchal translucency are excellent clinical indicators for fetal chromosome abnormality. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  16. Maternal Drug Abuse History, Maltreatment, and Functioning in a Clinical Sample of Urban Children

    Science.gov (United States)

    Onigu-Otite, Edore C.; Belcher, Harolyn M. E.

    2012-01-01

    Objective: This study examined the association between maternal drug abuse history, maltreatment exposure, and functioning, in a clinical sample of young children seeking therapy for maltreatment. Methods: Data were collected on 91 children, mean age 5.3 years (SD 1.0). The Preschool and Early Childhood Functional Assessment Scales (PECFAS) was…

  17. A COMPLETE SAMPLE OF BRIGHT SWIFT LONG GAMMA-RAY BURSTS. I. SAMPLE PRESENTATION, LUMINOSITY FUNCTION AND EVOLUTION

    International Nuclear Information System (INIS)

    Salvaterra, R.; Campana, S.; Vergani, S. D.; Covino, S.; D'Avanzo, P.; Fugazza, D.; Ghirlanda, G.; Ghisellini, G.; Melandri, A.; Sbarufatti, B.; Tagliaferri, G.; Nava, L.; Flores, H.; Piranomonte, S.

    2012-01-01

    We present a carefully selected sub-sample of Swift long gamma-ray bursts (GRBs) that is complete in redshift. The sample is constructed by considering only bursts with favorable observing conditions for ground-based follow-up searches, which are bright in the 15-150 keV Swift/BAT band, i.e., with 1-s peak photon fluxes in excess to 2.6 photons s –1 cm –2 . The sample is composed of 58 bursts, 52 of them with redshift for a completeness level of 90%, while another two have a redshift constraint, reaching a completeness level of 95%. For only three bursts we have no constraint on the redshift. The high level of redshift completeness allows us for the first time to constrain the GRB luminosity function and its evolution with cosmic times in an unbiased way. We find that strong evolution in luminosity (δ l = 2.3 ± 0.6) or in density (δ d = 1.7 ± 0.5) is required in order to account for the observations. The derived redshift distributions in the two scenarios are consistent with each other, in spite of their different intrinsic redshift distributions. This calls for other indicators to distinguish among different evolution models. Complete samples are at the base of any population studies. In future works we will use this unique sample of Swift bright GRBs to study the properties of the population of long GRBs.

  18. A COMPLETE SAMPLE OF BRIGHT SWIFT LONG GAMMA-RAY BURSTS. I. SAMPLE PRESENTATION, LUMINOSITY FUNCTION AND EVOLUTION

    Energy Technology Data Exchange (ETDEWEB)

    Salvaterra, R. [INAF, IASF Milano, via E. Bassini 15, I-20133 Milano (Italy); Campana, S.; Vergani, S. D.; Covino, S.; D' Avanzo, P.; Fugazza, D.; Ghirlanda, G.; Ghisellini, G.; Melandri, A.; Sbarufatti, B.; Tagliaferri, G. [INAF, Osservatorio Astronomico di Brera, via E. Bianchi 46, I-23807 Merate (Saint Lucia) (Italy); Nava, L. [SISSA, via Bonomea 265, I-34136 Trieste (Italy); Flores, H. [Laboratoire GEPI, Observatoire de Paris, CNRS-UMR8111, Univ. Paris-Diderot 5 place Jules Janssen, 92195 Meudon (France); Piranomonte, S., E-mail: ruben@lambrate.inaf.it [INAF, Osservatorio Astronomico di Roma, via Frascati 33, 00040 Monte Porzio Catone, Rome (Italy)

    2012-04-10

    We present a carefully selected sub-sample of Swift long gamma-ray bursts (GRBs) that is complete in redshift. The sample is constructed by considering only bursts with favorable observing conditions for ground-based follow-up searches, which are bright in the 15-150 keV Swift/BAT band, i.e., with 1-s peak photon fluxes in excess to 2.6 photons s{sup -1} cm{sup -2}. The sample is composed of 58 bursts, 52 of them with redshift for a completeness level of 90%, while another two have a redshift constraint, reaching a completeness level of 95%. For only three bursts we have no constraint on the redshift. The high level of redshift completeness allows us for the first time to constrain the GRB luminosity function and its evolution with cosmic times in an unbiased way. We find that strong evolution in luminosity ({delta}{sub l} = 2.3 {+-} 0.6) or in density ({delta}{sub d} = 1.7 {+-} 0.5) is required in order to account for the observations. The derived redshift distributions in the two scenarios are consistent with each other, in spite of their different intrinsic redshift distributions. This calls for other indicators to distinguish among different evolution models. Complete samples are at the base of any population studies. In future works we will use this unique sample of Swift bright GRBs to study the properties of the population of long GRBs.

  19. Obtaining a Functional Product Through the Exploitation of Mushroom Flour in Pasta

    Directory of Open Access Journals (Sweden)

    Crina Carmen MURESAN

    2017-05-01

    Full Text Available The present study focuses on the influence of adding mushroom powder on a certain assortment of pasta. The research comprises two major directions: the study of the raw materials used to produce pasta from a compositional point of view and the quantification of some biologically active compounds of interest; emphasizing the potential of using Boletus edulis mushroom powder in the composition of pasta and evaluating the quality of the product from a nutritional and sensorial point of view. For this purpose, two types of pasta have been created, with different percentages of mushroom, 10% and 20%, but also a blank sample obtained in the same conditions, but without mushroom powder. To achieve the goal the following analyzes were conducted: proteins, total polyphenols, antioxidant activity, fat, humidity, ashes, acidity, increase in volume of the boiled pasta and customers’ preferences. By using sensory analysis has been established that the consumers preferred pasta enriched with 10% mushroom powder. In conclusion, the addition of mushrooms flour assures an enhancement of the nutritional value, as well as of the organoleptic characteristics of the final product.

  20. An efficient and accurate method to obtain the energy-dependent Green function for general potentials

    International Nuclear Information System (INIS)

    Kramer, T; Heller, E J; Parrott, R E

    2008-01-01

    Time-dependent quantum mechanics provides an intuitive picture of particle propagation in external fields. Semiclassical methods link the classical trajectories of particles with their quantum mechanical propagation. Many analytical results and a variety of numerical methods have been developed to solve the time-dependent Schroedinger equation. The time-dependent methods work for nearly arbitrarily shaped potentials, including sources and sinks via complex-valued potentials. Many quantities are measured at fixed energy, which is seemingly not well suited for a time-dependent formulation. Very few methods exist to obtain the energy-dependent Green function for complicated potentials without resorting to ensemble averages or using certain lead-in arrangements. Here, we demonstrate in detail a time-dependent approach, which can accurately and effectively construct the energy-dependent Green function for very general potentials. The applications of the method are numerous, including chemical, mesoscopic, and atomic physics

  1. Effects of electroconvulsive therapy on amygdala function in major depression - a longitudinal functional magnetic resonance imaging study.

    Science.gov (United States)

    Redlich, R; Bürger, C; Dohm, K; Grotegerd, D; Opel, N; Zaremba, D; Meinert, S; Förster, K; Repple, J; Schnelle, R; Wagenknecht, C; Zavorotnyy, M; Heindel, W; Kugel, H; Gerbaulet, M; Alferink, J; Arolt, V; Zwanzger, P; Dannlowski, U

    2017-09-01

    Electroconvulsive therapy (ECT) is one of the most effective treatments for severe depression. However, little is known regarding brain functional processes mediating ECT effects. In a non-randomized prospective study, functional magnetic resonance imaging data during the automatic processing of subliminally presented emotional faces were obtained twice, about 6 weeks apart, in patients with major depressive disorder (MDD) before and after treatment with ECT (ECT, n = 24). Additionally, a control sample of MDD patients treated solely with pharmacotherapy (MED, n = 23) and a healthy control sample (HC, n = 22) were obtained. Before therapy, both patient groups equally showed elevated amygdala reactivity to sad faces compared with HC. After treatment, a decrease in amygdala activity to negative stimuli was discerned in both patient samples indicating a normalization of amygdala function, suggesting mechanisms potentially unspecific for ECT. Moreover, a decrease in amygdala activity to sad faces was associated with symptomatic improvements in the ECT sample (r spearman = -0.48, p = 0.044), and by tendency also for the MED sample (r spearman = -0.38, p = 0.098). However, we did not find any significant association between pre-treatment amygdala function to emotional stimuli and individual symptom improvement, neither for the ECT sample, nor for the MED sample. In sum, the present study provides first results regarding functional changes in emotion processing due to ECT treatment using a longitudinal design, thus validating and extending our knowledge gained from previous treatment studies. A limitation was that ECT patients received concurrent medication treatment.

  2. Impact of cleaning before obtaining midstream urine samples from children

    DEFF Research Database (Denmark)

    Lytzen, Rebekka; Knudsen, Jenny Dahl; Ladelund, Steen

    2014-01-01

    INTRODUCTION: Microbiological documentation of one uropathogenic bacterium in significant numbers in urine from patients with typical symptoms is the gold standard for diagnosing urinary tract infection (UTI). Cleaning before collecting midstream urine (MSU) is reported not to reduce the risk...... of contaminating the sample and was therefore omitted at Hvidovre Hospital as from the autumn of 2006. We evaluate if no cleaning increased the risk of contamination in the Department of Paediatrics. MATERIAL AND METHODS: A total of 1,858 patients aged 0-15 years who were suspected of UTI delivered two MSUs within...

  3. Accounting for animal movement in estimation of resource selection functions: sampling and data analysis.

    Science.gov (United States)

    Forester, James D; Im, Hae Kyung; Rathouz, Paul J

    2009-12-01

    Patterns of resource selection by animal populations emerge as a result of the behavior of many individuals. Statistical models that describe these population-level patterns of habitat use can miss important interactions between individual animals and characteristics of their local environment; however, identifying these interactions is difficult. One approach to this problem is to incorporate models of individual movement into resource selection models. To do this, we propose a model for step selection functions (SSF) that is composed of a resource-independent movement kernel and a resource selection function (RSF). We show that standard case-control logistic regression may be used to fit the SSF; however, the sampling scheme used to generate control points (i.e., the definition of availability) must be accommodated. We used three sampling schemes to analyze simulated movement data and found that ignoring sampling and the resource-independent movement kernel yielded biased estimates of selection. The level of bias depended on the method used to generate control locations, the strength of selection, and the spatial scale of the resource map. Using empirical or parametric methods to sample control locations produced biased estimates under stronger selection; however, we show that the addition of a distance function to the analysis substantially reduced that bias. Assuming a uniform availability within a fixed buffer yielded strongly biased selection estimates that could be corrected by including the distance function but remained inefficient relative to the empirical and parametric sampling methods. As a case study, we used location data collected from elk in Yellowstone National Park, USA, to show that selection and bias may be temporally variable. Because under constant selection the amount of bias depends on the scale at which a resource is distributed in the landscape, we suggest that distance always be included as a covariate in SSF analyses. This approach to

  4. BRDF of Salt Pan Regolith Samples

    Science.gov (United States)

    Georgiev, Georgi T.; Gatebe, Charles K.; Butler, James J.; King, Michael D.

    2008-01-01

    Laboratory Bi-directional Reflectance Distribution Function (BRDF) measurements of salt pan regolith samples are presented in this study in an effort to understand the role of spatial and spectral variability of the natural biome. The samples were obtained from Etosha Pan, Namibia (19.20 deg S, 15.93 deg E, alt. 1100 m). It is shown how the BRDF depends on the measurement geometry - incident and scatter angles and on the sample particle sizes. As a demonstration of the application of the results, airborne BRDF measurements acquires with NASA's Cloud Absorption Radiometer (CAR) over the same general site where the regolith samples were collected are compared with the laboratory results. Good agreement between laboratory measured and field measured BRDF is reported.

  5. Truncated States Obtained by Iteration

    International Nuclear Information System (INIS)

    Cardoso, W. B.; Almeida, N. G. de

    2008-01-01

    We introduce the concept of truncated states obtained via iterative processes (TSI) and study its statistical features, making an analogy with dynamical systems theory (DST). As a specific example, we have studied TSI for the doubling and the logistic functions, which are standard functions in studying chaos. TSI for both the doubling and logistic functions exhibit certain similar patterns when their statistical features are compared from the point of view of DST

  6. Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Tao; Tsui, Benjamin M. W.; Li, Xin; Vranesic, Melin; Lodge, Martin A.; Gulaldi, Nedim C. M.; Szabo, Zsolt, E-mail: zszabo@jhmi.edu [Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287 (United States)

    2015-11-15

    Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent

  7. Selective extraction of emerging contaminants from water samples by dispersive liquid-liquid microextraction using functionalized ionic liquids.

    Science.gov (United States)

    Yao, Cong; Li, Tianhao; Twu, Pamela; Pitner, William R; Anderson, Jared L

    2011-03-25

    Functionalized ionic liquids containing the tris(pentafluoroethyl)trifluorophosphate (FAP) anion were used as extraction solvents in dispersive liquid-liquid microextraction (DLLME) for the extraction of 14 emerging contaminants from water samples. The extraction efficiencies and selectivities were compared to those of an in situ IL DLLME method which uses an in situ metathesis reaction to exchange 1-butyl-3-methylimidazolium chloride (BMIM-Cl) to 1-butyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide (BMIM-NTf(2)). Compounds containing tertiary amine functionality were extracted with high selectivity and sensitivity by the 1-(6-amino-hexyl)-1-methylpyrrolidinium tris(pentafluoroethyl)trifluorophosphate (HNH(2)MPL-FAP) IL compared to other FAP-based ILs and the BMIM-NTf(2) IL. On the other hand, polar or acidic compounds without amine groups exhibited higher enrichment factors using the BMIM-NTf(2) IL. The detection limits for the studied analytes varied from 0.1 to 55.1 μg/L using the traditional IL DLLME method with the HNH(2)MPL-FAP IL as extraction solvent, and from 0.1 to 55.8 μg/L using in situ IL DLLME method with BMIM-Cl+LiNTf(2) as extraction solvent. A 93-fold decrease in the detection limit of caffeine was observed when using the HNH(2)MPL-FAP IL compared to that obtained using in situ IL DLLME method. Real water samples including tap water and creek water were analyzed with both IL DLLME methods and yielded recoveries ranging from 91% to 110%. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Failure Probability Calculation Method Using Kriging Metamodel-based Importance Sampling Method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seunggyu [Korea Aerospace Research Institue, Daejeon (Korea, Republic of); Kim, Jae Hoon [Chungnam Nat’l Univ., Daejeon (Korea, Republic of)

    2017-05-15

    The kernel density was determined based on sampling points obtained in a Markov chain simulation and was assumed to be an important sampling function. A Kriging metamodel was constructed in more detail in the vicinity of a limit state. The failure probability was calculated based on importance sampling, which was performed for the Kriging metamodel. A pre-existing method was modified to obtain more sampling points for a kernel density in the vicinity of a limit state. A stable numerical method was proposed to find a parameter of the kernel density. To assess the completeness of the Kriging metamodel, the possibility of changes in the calculated failure probability due to the uncertainty of the Kriging metamodel was calculated.

  9. Organizing heterogeneous samples using community detection of GIMME-derived resting state functional networks.

    Directory of Open Access Journals (Sweden)

    Kathleen M Gates

    Full Text Available Clinical investigations of many neuropsychiatric disorders rely on the assumption that diagnostic categories and typical control samples each have within-group homogeneity. However, research using human neuroimaging has revealed that much heterogeneity exists across individuals in both clinical and control samples. This reality necessitates that researchers identify and organize the potentially varied patterns of brain physiology. We introduce an analytical approach for arriving at subgroups of individuals based entirely on their brain physiology. The method begins with Group Iterative Multiple Model Estimation (GIMME to assess individual directed functional connectivity maps. GIMME is one of the only methods to date that can recover both the direction and presence of directed functional connectivity maps in heterogeneous data, making it an ideal place to start since it addresses the problem of heterogeneity. Individuals are then grouped based on similarities in their connectivity patterns using a modularity approach for community detection. Monte Carlo simulations demonstrate that using GIMME in combination with the modularity algorithm works exceptionally well--on average over 97% of simulated individuals are placed in the accurate subgroup with no prior information on functional architecture or group identity. Having demonstrated reliability, we examine resting-state data of fronto-parietal regions drawn from a sample (N = 80 of typically developing and attention-deficit/hyperactivity disorder (ADHD -diagnosed children. Here, we find 5 subgroups. Two subgroups were predominantly comprised of ADHD, suggesting that more than one biological marker exists that can be used to identify children with ADHD based from their brain physiology. Empirical evidence presented here supports notions that heterogeneity exists in brain physiology within ADHD and control samples. This type of information gained from the approach presented here can assist in

  10. Sample Data Synchronization and Harmonic Analysis Algorithm Based on Radial Basis Function Interpolation

    Directory of Open Access Journals (Sweden)

    Huaiqing Zhang

    2014-01-01

    Full Text Available The spectral leakage has a harmful effect on the accuracy of harmonic analysis for asynchronous sampling. This paper proposed a time quasi-synchronous sampling algorithm which is based on radial basis function (RBF interpolation. Firstly, a fundamental period is evaluated by a zero-crossing technique with fourth-order Newton’s interpolation, and then, the sampling sequence is reproduced by the RBF interpolation. Finally, the harmonic parameters can be calculated by FFT on the synchronization of sampling data. Simulation results showed that the proposed algorithm has high accuracy in measuring distorted and noisy signals. Compared to the local approximation schemes as linear, quadric, and fourth-order Newton interpolations, the RBF is a global approximation method which can acquire more accurate results while the time-consuming is about the same as Newton’s.

  11. Mixed functional monomers-based monolithic adsorbent for the effective extraction of sulfonylurea herbicides in water and soil samples.

    Science.gov (United States)

    Pei, Miao; Zhu, Xiangyu; Huang, Xiaojia

    2018-01-05

    Effective extraction is a key step in the determination of sulfonylurea herbicides (SUHs) in complicated samples. According to the chemical properties of SUHs, a new monolithic adsorbent utilizing acrylamidophenylboronic acid and vinylimidazole as mixed functional monomers was synthesized. The new adsorbent was employed as the extraction phase of multiple monolithic fiber solid-phase microextraction (MMF-SPME) of SUHs, and the extracted SUHs were determined by high-performance liquid chromatography with diode array detection (HPLC-DAD). Results well evidence that the prepared adsorbent could extract SUHs in environmental waters and soil effectively through multiply interactions such as boronate affinity, dipole-dipole and π-π interactions. Under the optimized extraction conditions, the limits of detection for target SUHs in environmental water and soil samples were 0.018-0.17μg/L and 0.14-1.23μg/kg, respectively. At the same time, the developed method also displayed some analytical merits including wide linear dynamic ranges, good method reproducibility, satisfactory sensitivity and low consume of organic solvent. Finally, the developed were successfully applied to monitor trace SUHs in environmental water and soil samples. The recoveries at three fortified concentrations were in the range of 70.6-119% with RSD below 11% in all cases. The obtained results well demonstrate the excellent practical applicability of the developed MMF-SPME-HPLC-DAD method for the monitoring of SUHs in water and soil samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Determination of the content of fatty acid methyl esters (FAME) in biodiesel samples obtained by esterification using 1H-NMR spectroscopy.

    Science.gov (United States)

    Mello, Vinicius M; Oliveira, Flavia C C; Fraga, William G; do Nascimento, Claudia J; Suarez, Paulo A Z

    2008-11-01

    Three different calibration curves based on (1)H-NMR spectroscopy (300 MHz) were used for quantifying the reaction yield during biodiesel synthesis by esterification of fatty acids mixtures and methanol. For this purpose, the integrated intensities of the hydrogens of the ester methoxy group (3.67 ppm) were correlated with the areas related to the various protons of the alkyl chain (olefinic hydrogens: 5.30-5.46 ppm; aliphatic: 2.67-2.78 ppm, 2.30 ppm, 1.96-2.12 ppm, 1.56-1.68 ppm, 1.22-1.42 ppm, 0.98 ppm, and 0.84-0.92 ppm). The first curve was obtained using the peaks relating the olefinic hydrogens, a second with the parafinic protons and the third curve using the integrated intensities of all the hydrogens. A total of 35 samples were examined: 25 samples to build the three different calibration curves and ten samples to serve as external validation samples. The results showed no statistical differences among the three methods, and all presented prediction errors less than 2.45% with a co-efficient of variation (CV) of 4.66%. 2008 John Wiley & Sons, Ltd.

  13. PbSe nanocubes obtained by high-energy milling

    Energy Technology Data Exchange (ETDEWEB)

    Rojas-Chavez, H., E-mail: hrojasc@ipn.mx [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada - IPN (Mexico); Reyes-Carmona, F. [Facultad de Quimica - UNAM (Mexico); Achimovicova, M. [Slovak Academy of Sciences, Institute of Geotechnics (Slovakia); Daneu, N. [Jozef Stefan Institute, Department for Nanostructured Materials (Slovenia); Jaramillo-Vigueras, D. [Centro de Investigacion e Innovacion Tecnologica - IPN (Mexico)

    2012-06-15

    In this study, PbSe nanocubes were obtained by high-energy milling, and their optical properties were investigated by measuring the UV-VIS-IR spectra in the range of 200-2,000 nm. The optical absorption of all samples showed a strong UV emission band at 1.45 eV. Previously, to obtain only PbSe nanocubes, an intermediate phase was identified, PbSeO{sub 3}. Although both PbSeO{sub 3} and PbSe were traced through this study, a major effort is devoted to characterize the latter. To trace how chemical transitions evolve from precursors to PbSe, X-ray diffraction and Rietveld refinement were carried out. Therefore, the following parameters were evaluated as a function of milling time: phase percentages, area-to-volume ratio, average crystallite dimensions, specific surface area, and morphology changes. To corroborate previous findings, nitrogen adsorption and transmission electron microscopy techniques were used. All the set experimental results unambiguously confirm that crystallites show a cubic morphology, with its average crystallite size distribution being around 24 nm.

  14. Sampled control of vibration in suspended cask by using vibration manipulation functions

    International Nuclear Information System (INIS)

    Kotake, Shigeo

    2014-01-01

    Safe and reliable operation is most important for decommissioning the Fukushima 1 nuclear power plant. Especially it requires for transferring spent nuclear fuels from fuel pool to storage cask. Since the heavy cask will be suspended during the transferring operation, there is a risk of dropping it in case of the strike of large earthquakes. In this study, we introduce analytical functions to suppress residual vibration of a suspended cask by using vibration manipulation function. Hence the oscillation of the cask can be feedforward or sampled-data controlled by moving a trolley with analog actuator, the possible risk could be reduced. (author)

  15. Sample vial inserts: A better approach for sampling heterogeneous slurry samples in the SRS Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Goode, S.R.

    1996-01-01

    A convenient and effective new approach for analyzing DWPF samples involves the use of inserts with volumes of 1.5--3 ml placed in the neck of 14 ml sample vials. The inserts have rims that conform to the rim of the vials so that they sit straight and stable in the vial. The DWPF tank sampling system fills the pre-weighed insert rather than the entire vial, so the vial functions only as the insert holder. The shielded cell operator then removes the vial cap and decants the insert containing the sample into a plastic bottle, crucible, etc., for analysis. Inert materials such as Teflon, plastic, and zirconium are used for the insert so it is unnecessary to separate the insert from the sample for most analyses. The key technique advantage of using inserts to take DWPF samples versus filling sample vials is that it provides a convenient and almost foolproof way of obtaining and handling small volumes of slurry samples in a shielded cell without corrupting the sample. Since the insert allows the entire sample to be analyzed, this approach eliminates the errors inherent with subsampling heterogeneous slurries that comprise DWPF samples. Slurry samples can then be analyzed with confidence. Analysis times are dramatically reduced by eliminating the drying and vitrification steps normally used to produce a homogeneous solid sample. Direct dissolution and elemental analysis of slurry samples are achieved in 8 hours or less compared with 40 hours for analysis of vitrified slurry samples. Comparison of samples taken in inserts versus full vials indicate that the insert does not significantly affect sample composition

  16. Mechanical properties and filler distribution as a function filler content in silica filled PDMS samples

    International Nuclear Information System (INIS)

    Hawley, Marilyn E.; Wrobleski, Debra A.; Orler, E. Bruce; Houlton, Robert J.; Chitanvis, Kiran E.; Brown, Geoffrey W.; Hanson, David E.

    2004-01-01

    Atomic force microscopy (AFM) phase imaging and tensile stress-strain measurements are used to study a series of model compression molded fumed silica filled polydimethysiloxane (PDMS) samples with filler content of zero, 20, 35, and 50 parts per hundred (phr) to determine the relationship between filler content and stress-strain properties. AFM phase imaging was used to determine filler size, degree of aggregation, and distribution within the soft PDMS matrix. A small tensile stage was used to measure mechanical properties. Samples were not pulled to break in order to study Mullins and aging effects. Several identical 35 phr samples were subjected to an initial stress, and then one each was reevaluated over intervals up to 26 weeks to determine the degree to which these samples recovered their initial stress-strain behavior as a function of time. One sample was tested before and after heat treatment to determine if heating accelerated recovery of the stress-strain behavior. The effect of filler surface treatment on mechanical properties was examined for two samples containing 35 phr filler treated or untreated with hexamethyldisilazane (HMDZ), respectively. Fiduciary marks were used on several samples to determine permanent set. 35 phr filler samples were found to give the optimum mechanical properties. A clear Mullins effect was seen. Within experimental error, no change was seen in mechanical behavior as a function of time or heat-treatment. The mechanical properties of the sample containing the HDMZ treated silica were adversely affected. AFM phase images revealed aggregation and nonuniform distribution of the filler for all samples. Finally, a permanent set of about 3 to 6 percent was observed for the 35 phr samples.

  17. Determination of average activating thermal neutron flux in bulk samples

    International Nuclear Information System (INIS)

    Doczi, R.; Csikai, J.; Doczi, R.; Csikai, J.; Hassan, F. M.; Ali, M.A.

    2004-01-01

    A previous method used for the determination of the average neutron flux within bulky samples has been applied for the measurements of hydrogen contents of different samples. An analytical function is given for the description of the correlation between the activity of Dy foils and the hydrogen concentrations. Results obtained by the activation and the thermal neutron reflection methods are compared

  18. Efficient computation of smoothing splines via adaptive basis sampling

    KAUST Repository

    Ma, Ping

    2015-06-24

    © 2015 Biometrika Trust. Smoothing splines provide flexible nonparametric regression estimators. However, the high computational cost of smoothing splines for large datasets has hindered their wide application. In this article, we develop a new method, named adaptive basis sampling, for efficient computation of smoothing splines in super-large samples. Except for the univariate case where the Reinsch algorithm is applicable, a smoothing spline for a regression problem with sample size n can be expressed as a linear combination of n basis functions and its computational complexity is generally O(n3). We achieve a more scalable computation in the multivariate case by evaluating the smoothing spline using a smaller set of basis functions, obtained by an adaptive sampling scheme that uses values of the response variable. Our asymptotic analysis shows that smoothing splines computed via adaptive basis sampling converge to the true function at the same rate as full basis smoothing splines. Using simulation studies and a large-scale deep earth core-mantle boundary imaging study, we show that the proposed method outperforms a sampling method that does not use the values of response variables.

  19. Efficient computation of smoothing splines via adaptive basis sampling

    KAUST Repository

    Ma, Ping; Huang, Jianhua Z.; Zhang, Nan

    2015-01-01

    © 2015 Biometrika Trust. Smoothing splines provide flexible nonparametric regression estimators. However, the high computational cost of smoothing splines for large datasets has hindered their wide application. In this article, we develop a new method, named adaptive basis sampling, for efficient computation of smoothing splines in super-large samples. Except for the univariate case where the Reinsch algorithm is applicable, a smoothing spline for a regression problem with sample size n can be expressed as a linear combination of n basis functions and its computational complexity is generally O(n3). We achieve a more scalable computation in the multivariate case by evaluating the smoothing spline using a smaller set of basis functions, obtained by an adaptive sampling scheme that uses values of the response variable. Our asymptotic analysis shows that smoothing splines computed via adaptive basis sampling converge to the true function at the same rate as full basis smoothing splines. Using simulation studies and a large-scale deep earth core-mantle boundary imaging study, we show that the proposed method outperforms a sampling method that does not use the values of response variables.

  20. Metabolic liver function measured in vivo by dynamic (18)F-FDGal PET/CT without arterial blood sampling.

    Science.gov (United States)

    Horsager, Jacob; Munk, Ole Lajord; Sørensen, Michael

    2015-01-01

    Metabolic liver function can be measured by dynamic PET/CT with the radio-labelled galactose-analogue 2-[(18)F]fluoro-2-deoxy-D-galactose ((18)F-FDGal) in terms of hepatic systemic clearance of (18)F-FDGal (K, ml blood/ml liver tissue/min). The method requires arterial blood sampling from a radial artery (arterial input function), and the aim of this study was to develop a method for extracting an image-derived, non-invasive input function from a volume of interest (VOI). Dynamic (18)F-FDGal PET/CT data from 16 subjects without liver disease (healthy subjects) and 16 patients with liver cirrhosis were included in the study. Five different input VOIs were tested: four in the abdominal aorta and one in the left ventricle of the heart. Arterial input function from manual blood sampling was available for all subjects. K*-values were calculated using time-activity curves (TACs) from each VOI as input and compared to the K-value calculated using arterial blood samples as input. Each input VOI was tested on PET data reconstructed with and without resolution modelling. All five image-derived input VOIs yielded K*-values that correlated significantly with K calculated using arterial blood samples. Furthermore, TACs from two different VOIs yielded K*-values that did not statistically deviate from K calculated using arterial blood samples. A semicircle drawn in the posterior part of the abdominal aorta was the only VOI that was successful for both healthy subjects and patients as well as for PET data reconstructed with and without resolution modelling. Metabolic liver function using (18)F-FDGal PET/CT can be measured without arterial blood samples by using input data from a semicircle VOI drawn in the posterior part of the abdominal aorta.

  1. Time-dependent importance sampling in semiclassical initial value representation calculations for time correlation functions. II. A simplified implementation.

    Science.gov (United States)

    Tao, Guohua; Miller, William H

    2012-09-28

    An efficient time-dependent (TD) Monte Carlo (MC) importance sampling method has recently been developed [G. Tao and W. H. Miller, J. Chem. Phys. 135, 024104 (2011)] for the evaluation of time correlation functions using the semiclassical (SC) initial value representation (IVR) methodology. In this TD-SC-IVR method, the MC sampling uses information from both time-evolved phase points as well as their initial values, and only the "important" trajectories are sampled frequently. Even though the TD-SC-IVR was shown in some benchmark examples to be much more efficient than the traditional time-independent sampling method (which uses only initial conditions), the calculation of the SC prefactor-which is computationally expensive, especially for large systems-is still required for accepted trajectories. In the present work, we present an approximate implementation of the TD-SC-IVR method that is completely prefactor-free; it gives the time correlation function as a classical-like magnitude function multiplied by a phase function. Application of this approach to flux-flux correlation functions (which yield reaction rate constants) for the benchmark H + H(2) system shows very good agreement with exact quantum results. Limitations of the approximate approach are also discussed.

  2. Plasma functionalization of powdery nanomaterials using porous filter electrode and sample circulation

    Science.gov (United States)

    Lee, Deuk Yeon; Choi, Jae Hong; Shin, Jung Chul; Jung, Man Ki; Song, Seok Kyun; Suh, Jung Ki; Lee, Chang Young

    2018-06-01

    Compared with wet processes, dry functionalization using plasma is fast, scalable, solvent-free, and thus presents a promising approach for grafting functional groups to powdery nanomaterials. Previous approaches, however, had difficulties in maintaining an intimate sample-plasma contact and achieving uniform functionalization. Here, we demonstrate a plasma reactor equipped with a porous filter electrode that increases both homogeneity and degree of functionalization by capturing and circulating powdery carbon nanotubes (CNTs) via vacuum and gas blowing. Spectroscopic measurements verify that treatment with O2/air plasma generates oxygen-containing groups on the surface of CNTs, with the degree of functionalization readily controlled by varying the circulation number. Gas sensors fabricated using the plasma-treated CNTs confirm alteration of molecular adsorption on the surface of CNTs. A sequential treatment with NH3 plasma following the oxidation pre-treatment results in the functionalization with nitrogen species of up to 3.2 wt%. Our approach requiring no organic solvents not only is cost-effective and environmentally friendly, but also serves as a versatile tool that applies to other powdery micro or nanoscale materials for controlled modification of their surfaces.

  3. Proteomic Challenges: Sample Preparation Techniques for Microgram-Quantity Protein Analysis from Biological Samples

    Directory of Open Access Journals (Sweden)

    Peter Feist

    2015-02-01

    Full Text Available Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed.

  4. Proteomic Challenges: Sample Preparation Techniques for Microgram-Quantity Protein Analysis from Biological Samples

    Science.gov (United States)

    Feist, Peter; Hummon, Amanda B.

    2015-01-01

    Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower) and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed. PMID:25664860

  5. Proteomic challenges: sample preparation techniques for microgram-quantity protein analysis from biological samples.

    Science.gov (United States)

    Feist, Peter; Hummon, Amanda B

    2015-02-05

    Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower) and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed.

  6. Synthesis and Thermal Characterization of Hydroxyapatite Powders Obtained by Sol-Gel Technique

    Science.gov (United States)

    Jiménez-Flores, Y.; Camacho, N.; Rojas-Trigos, J. B.; Suárez, M.

    The development of bioactive materials presents an interesting and an extremely relevant problem to solve, in the development of customized cranial and maxillofacial prosthesis, bioactive coating, and cements, for example. In such areas, one of the more employed materials is the synthetic hydroxyapatite, due to its proved biocompatibility with the human body; however, there are few studies about the thermal affinity with the biological surroundings, and most of them are centered in the thermal stability of the hydroxyapatite instead of its transient thermal response. In the present paper, the synthesis and physical-chemical characterization of hydroxyapatite samples, obtained by the sol-gel technique employing ultrasonic mixing, are reported. Employing X-ray diffraction patterns, XEDS and FTIR spectra, the crystal symmetry, chemical elements, and the present functional groups of the studied samples were determined and found to correspond to those reported in the literature, with a stoichiometry close to the ideal for biological applications. Additionally, by means of the photoacoustic detection and infrared photothermal radiometry (IPTR) techniques, the thermal response of the samples was obtained. Analyzing the photoacoustic data, the synthetized samples show photoacoustic opaqueness, responding in the thermally thick regime in the measurement range, and their thermal effusivity was also determined, having values of 1.47 folds the thermal effusivity of the mandibular human bone. Finally, from the IPTR measurements, the thermal diffusivity and thermal conductivity of the samples were also determined, having good agreement with the reported values for synthetic hydroxyapatite. The structural and thermophysical properties of the here reported samples show that the synthesized samples have good thermal affinity with the mandibular human bone tissue, and are suitable for biomedical applications.

  7. Perspectives among a Diverse Sample of Women on the Possibility of Obtaining Oral Contraceptives Over the Counter: A Qualitative Study.

    Science.gov (United States)

    Baum, Sarah; Burns, Bridgit; Davis, Laura; Yeung, Miriam; Scott, Cherisse; Grindlay, Kate; Grossman, Daniel

    2016-01-01

    There is increasing support among stakeholders in the United States to make oral contraceptives (OCs) available over the counter (OTC). Previous research on the topic has focused on representative samples of U.S. women, Latina women, low-income women, and abortion clients. However, little is known about the perspectives of African American women, Asian American women, and young women. We conducted 14 focus group discussions with 138 women. Twenty-three percent of participants were ages 18 or younger, 61% were African American, and 26% were Asian American/Pacific Islander. Community organizations recruited participants through convenience sampling and hosted the discussions. Focus groups were transcribed and coded thematically. Women reported potential benefits of OTC access, including convenience and privacy. Many believed OTC availability of OCs would help to reduce unintended pregnancy and help to destigmatize birth control. Participants also expressed concerns about OTC access, such as worry that first-time users and young adolescents would not have enough information to use the pill safely and effectively, as well as concerns about whether women would still obtain preventive screenings. Women were also worried that the cost of OTC OCs would be higher if insurance no longer covered them. Overall, women were interested in the option of obtaining the pill OTC. Future research and advocacy efforts should explore women's concerns, including whether adolescents can effectively use OTC pills and ensuring insurance coverage for OTC contraception. Copyright © 2016 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  8. Processing of response functions obtained by radiotracer measurements. XIII

    International Nuclear Information System (INIS)

    Thyn, J.; Havlicek, A.

    1982-01-01

    The segregation of fodder mixtures during filling and emptying of storage tanks was evaluated statistically using significance tests and by the frequency characteristics method evaluating system by the gain coefficient. The gain coefficient is determined from the self-correlation function of tracer concentration variations during filling and from the self-correlation function of tracer concentration variations during emptying. The described methods of experimental data processing were used for the evaluation of industrial cylindrical storage tanks with differently shaped hoppers (rectangular or circular central hole). 24 Na in the form of ground sodium carb--onate was used as a tracer. (author)

  9. Comparison of radon and radon-daughter grab samples obtained during the winter and summer

    International Nuclear Information System (INIS)

    Karp, K.E.

    1987-08-01

    The Technical Measurements Center (TMC), under the auspices of the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) program, is investigating short-term methods for estimating annual average indoor radon-daughter concentrations (RDC). A field study at 40 sample locations in 26 residential structures in Grand Junction, Colorado, was conducted once in the winter and once in the summer. The short-term methods investigated as part of this study include ten-minute radon and radon-daughter grab sampling and hourly RDC measurements. The results of the field study indicate that ten-minute radon grab samples from basement locations are reproducible over different seasons during controlled sampling conditions. Nonbasement radon and RDC grab samples are highly variable even when the use of the location by the occupant is controlled and the ventilation rate is restricted. The grab sampling was performed under controlled occupied conditions. These results confirm that a short-term radon or RDC measurement in a nonbasement location in a house is not a standardized measurement that can be used to infer an annual average concentration. The hourly RDC measurements were performed under three sets of conditions over a 72-hour period. The three sets of conditions were uncontrolled occupied, controlled occupied, and controlled unoccupied. These results indicate that it is not necessary to relocate the occupants during the time of grab sampling. 8 refs., 8 figs., 10 tabs

  10. Minimally invasive input function for 2-{sup 18}F-fluoro-A-85380 brain PET studies

    Energy Technology Data Exchange (ETDEWEB)

    Zanotti-Fregonara, Paolo [National Institute of Mental Health, NIH, Molecular Imaging Branch, Bethesda, MD (United States); Maroy, Renaud; Peyronneau, Marie-Anne; Trebossen, Regine [CEA, DSV, I2BM, Service Hospitalier Frederic Joliot, Orsay (France); Bottlaender, Michel [CEA, DSV, I2BM, NeuroSpin, Gif-sur-Yvette (France)

    2012-04-15

    Quantitative neuroreceptor positron emission tomography (PET) studies often require arterial cannulation to measure input function. While population-based input function (PBIF) would be a less invasive alternative, it has only rarely been used in conjunction with neuroreceptor PET tracers. The aims of this study were (1) to validate the use of PBIF for 2-{sup 18}F-fluoro-A-85380, a tracer for nicotinic receptors; (2) to compare the accuracy of measures obtained via PBIF to those obtained via blood-scaled image-derived input function (IDIF) from carotid arteries; and (3) to explore the possibility of using venous instead of arterial samples for both PBIF and IDIF. Ten healthy volunteers underwent a dynamic 2-{sup 18}F-fluoro-A-85380 brain PET scan with arterial and, in seven subjects, concurrent venous serial blood sampling. PBIF was obtained by averaging the normalized metabolite-corrected arterial input function and subsequently scaling each curve with individual blood samples. IDIF was obtained from the carotid arteries using a blood-scaling method. Estimated Logan distribution volume (V{sub T}) values were compared to the reference values obtained from arterial cannulation. For all subjects, PBIF curves scaled with arterial samples were similar in shape and magnitude to the reference arterial input function. The Logan V{sub T} ratio was 1.00 {+-} 0.05; all subjects had an estimation error <10%. IDIF gave slightly less accurate results (V{sub T} ratio 1.03 {+-} 0.07; eight of ten subjects had an error <10%). PBIF scaled with venous samples yielded inaccurate results (V{sub T} ratio 1.13 {+-} 0.13; only three of seven subjects had an error <10%). Due to arteriovenous differences at early time points, IDIF could not be calculated using venous samples. PBIF scaled with arterial samples accurately estimates Logan V{sub T} for 2-{sup 18}F-fluoro-A-85380. Results obtained with PBIF were slightly better than those obtained with IDIF. Due to arteriovenous concentration

  11. Hierarchical Coupling of First-Principles Molecular Dynamics with Advanced Sampling Methods.

    Science.gov (United States)

    Sevgen, Emre; Giberti, Federico; Sidky, Hythem; Whitmer, Jonathan K; Galli, Giulia; Gygi, Francois; de Pablo, Juan J

    2018-05-14

    We present a seamless coupling of a suite of codes designed to perform advanced sampling simulations, with a first-principles molecular dynamics (MD) engine. As an illustrative example, we discuss results for the free energy and potential surfaces of the alanine dipeptide obtained using both local and hybrid density functionals (DFT), and we compare them with those of a widely used classical force field, Amber99sb. In our calculations, the efficiency of first-principles MD using hybrid functionals is augmented by hierarchical sampling, where hybrid free energy calculations are initiated using estimates obtained with local functionals. We find that the free energy surfaces obtained from classical and first-principles calculations differ. Compared to DFT results, the classical force field overestimates the internal energy contribution of high free energy states, and it underestimates the entropic contribution along the entire free energy profile. Using the string method, we illustrate how these differences lead to different transition pathways connecting the metastable minima of the alanine dipeptide. In larger peptides, those differences would lead to qualitatively different results for the equilibrium structure and conformation of these molecules.

  12. Different Characteristics of the Female Sexual Function Index in a Sample of Sexually Active and Inactive Women.

    Science.gov (United States)

    Hevesi, Krisztina; Mészáros, Veronika; Kövi, Zsuzsanna; Márki, Gabriella; Szabó, Marianna

    2017-09-01

    The Female Sexual Function Index (FSFI) is a widely used measurement tool to assess female sexual function along the six dimensions of desire, arousal, lubrication, orgasm, satisfaction, and pain. However, the structure of the questionnaire is not clear, and several studies have found high correlations among the dimensions, indicating that a common underlying "sexual function" factor might be present. To investigate whether female sexual function is best understood as a multidimensional construct or, alternatively, whether a common underlying factor explains most of the variance in FSFI scores, and to investigate the possible effect of the common practice of including sexually inactive women in studies using the FSFI. The sample consisted of 508 women: 202 university students, 177 patients with endometriosis, and 129 patients with polycystic ovary syndrome. Participants completed the FSFI, and confirmatory factor analyses were used to test the underlying structure of this instrument in the total sample and in samples including sexually active women only. The FSFI is a multidimensional self-report questionnaire composed of 19 items. Strong positive correlations were found among five of the six original factors on the FSFI. Confirmatory factor analyses showed that in the total sample items loaded mainly on the general sexual function factor and very little variance was explained by the specific factors. However, when only sexually active women were included in the analyses, a clear factor structure emerged, with items loading on their six specific factors, and most of the variance in FSFI scores was explained by the specific factors, rather than the general factor. University students reported higher scores, indicating better functioning compared with the patient samples. The reliable and valid assessment of female sexual function can contribute to better understanding, prevention, and treatment of different sexual difficulties and dysfunctions. This study provides a

  13. Reliability and validity of the Persian lower extremity functional scale (LEFS) in a heterogeneous sample of outpatients with lower limb musculoskeletal disorders.

    Science.gov (United States)

    Negahban, Hossein; Hessam, Masumeh; Tabatabaei, Saeid; Salehi, Reza; Sohani, Soheil Mansour; Mehravar, Mohammad

    2014-01-01

    The aim was to culturally translate and validate the Persian lower extremity functional scale (LEFS) in a heterogeneous sample of outpatients with lower extremity musculoskeletal disorders (n = 304). This is a prospective methodological study. After a standard forward-backward translation, psychometric properties were assessed in terms of test-retest reliability, internal consistency, construct validity, dimensionality, and ceiling or floor effects. The acceptable level of intraclass correlation coefficient >0.70 and Cronbach's alpha coefficient >0.70 was obtained for the Persian LEFS. Correlations between Persian LEFS and Short-Form 36 Health Survey (SF-36) subscales of Physical Health component (rs range = 0.38-0.78) were higher than correlations between Persian LEFS and SF-36 subscales of Mental Health component (rs range = 0.15-0.39). A corrected item--total correlation of >0.40 (Spearman's rho) was obtained for all items of the Persian LEFS. Horn's parallel analysis detected a total of two factors. No ceiling or floor effects were detected for the Persian LEFS. The Persian version of the LEFS is a reliable and valid instrument that can be used to measure functional status in Persian-speaking patients with different musculoskeletal disorders of the lower extremity. Implications for Rehabilitation The Persian lower extremity functional scale (LEFS) is a reliable, internally consistent and valid instrument, with no ceiling or floor effects, to determine functional status of heterogeneous patients with musculoskeletal disorders of the lower extremity. The Persian version of the LEFS can be used in clinical and research settings to measure function in Iranian patients with different musculoskeletal disorders of the lower extremity.

  14. Comparison of 230Th/234U Dating Results Obtained on Fossil Mollusk Shell from Morocco and Fossil Coral Samples from Egypt. Research of Methodological Criteria to Valid the Measured Age

    International Nuclear Information System (INIS)

    Choukri, A.; Hakam, O.K.; Reyss, J.L.

    2013-01-01

    Radiochemical ages of 126 unrecrystallized coral samples from the Egyptian shoreline and 125 fossil mollusk shell samples from the Atlantic coast of Moroccan High Atlas are discussed.For corals, the obtained ages are in good agreement with the ages reported previously on urecristallized corals except in some sites where some samples are affected by a cementation of younger aragonite.For mollusk shells, the obtained ages are in the most of cases, rejuvenated.This rejuvenation is due eventually to a post-incorporation of secondary uranium that is responsible of the wide dispersion of apparent ages of mollusk shells.

  15. Comparison of Hematologic and Biochemical Test Results in Blood Samples Obtained by Jugular Venipuncture Versus Nail Clip in Moluccan Cockatoos (Cacatua moluccensis).

    Science.gov (United States)

    Bennett, Tracy D; Lejnieks, Daniel V; Koepke, Hoyt; Grimson, Fiona; Szucs, Jennifer; Omaits, Kerri; Lane, Rosalie

    2015-12-01

    In birds, blood samples are often collected from the jugular, medial metatarsal, and basilic vein. Samples are sometimes collected by toe nail clip, but concerns to avoid drawing blood from the nail include pain after nail clips for blood collection, potential differences in complete blood count (CBC) results, and potential contamination with uric acid values. To compare differences in biochemical and hematologic values in blood samples obtained by jugular venipuncture versus toenail clip, blood samples were collected from Moluccan cockatoos (Cacatua moluccensis) (N = 23) and sent to a commercial laboratory for routine CBCs and serum biochemical analysis. Results showed good agreement between venipuncture and nail clip blood samples in red blood cell count, packed cell volume, heterophil count and percentage, lymphocyte count and percentage, aspartate aminotransferase, chloride, creatine phosphokinase, glucose, lactate dehydrogenase, total protein, and uric acid values. Constant bias was found in values of bile acids, cholesterol, and hemoglobin. Proportional bias toward higher values in the jugular sample were found in total white blood cell (WBC) count and inorganic phosphorus. Serum calcium plots revealed a proportional bias toward higher values in the toe nail blood when values were increased. Results suggest some differences in WBC count, bile acids, calcium, cholesterol, hemoglobin, and phosphorus values between blood samples collected by jugular venipuncture and samples collected by toe nail clip, but the differences are mostly minor and, with the possible exception of inorganic phosphorus and marginally elevated or very low WBC counts, are unlikely to affect the use or interpretation of the avian blood panel.

  16. Efficiency corrections in determining the 137Cs inventory of environmental soil samples by using relative measurement method and GEANT4 simulations

    International Nuclear Information System (INIS)

    Li, Gang; Liang, Yongfei; Xu, Jiayun; Bai, Lixin

    2015-01-01

    The determination of 137 Cs inventory is widely used to estimate the soil erosion or deposition rate. The generally used method to determine the activity of volumetric samples is the relative measurement method, which employs a calibration standard sample with accurately known activity. This method has great advantages in accuracy and operation only when there is a small difference in elemental composition, sample density and geometry between measuring samples and the calibration standard. Otherwise it needs additional efficiency corrections in the calculating process. The Monte Carlo simulations can handle these correction problems easily with lower financial cost and higher accuracy. This work presents a detailed description to the simulation and calibration procedure for a conventionally used commercial P-type coaxial HPGe detector with cylindrical sample geometry. The effects of sample elemental composition, density and geometry were discussed in detail and calculated in terms of efficiency correction factors. The effect of sample placement was also analyzed, the results indicate that the radioactive nuclides and sample density are not absolutely uniform distributed along the axial direction. At last, a unified binary quadratic functional relationship of efficiency correction factors as a function of sample density and height was obtained by the least square fitting method. This function covers the sample density and height range of 0.8–1.8 g/cm 3 and 3.0–7.25 cm, respectively. The efficiency correction factors calculated by the fitted function are in good agreement with those obtained by the GEANT4 simulations with the determination coefficient value greater than 0.9999. The results obtained in this paper make the above-mentioned relative measurements more accurate and efficient in the routine radioactive analysis of environmental cylindrical soil samples. - Highlights: • Determination of 137 Cs inventory in environmental soil samples by using relative

  17. Functionalization of nanoparticle titanium dioxide with different bifunctional organic molecules and trimers of transition compounds for obtaining new materials

    International Nuclear Information System (INIS)

    Rivera Martinez, Maria Cinthya

    2012-01-01

    Functionalization of titanium dioxide in nanoporous anatase phase is investigated for obtaining new nanomaterials. Functionalizations were performed using two heating methods: the conventional of refluxing heating method and microwave irradiation with bifunctional organic molecules is used to study how to anchor molecules and the change in the wettability of the material. Besides, reactions with organic molecules were performed as the derived from nanoproxene. The growth layer by layer is performed using the bifunctional molecules previous for the immobilization of cobalt trimers. Functionalized molecules were characterized by infrared spectroscopy, X-ray diffraction, contact angle, scanning electron microscopy, x-ray elemental analysis, plasma atomic emission spectroscopy coupled inductively, x-ray photoelectron spectroscopy and thermogravimetric analysis. This type of functionalizations on nanoporous titanium dioxide could potentially improve optical sensitivity and activity of this nanomaterial in the visible region. (author) [es

  18. Laboratory and Airborne BRDF Analysis of Vegetation Leaves and Soil Samples

    Science.gov (United States)

    Georgiev, Georgi T.; Gatebe, Charles K.; Butler, James J.; King, Michael D.

    2008-01-01

    Laboratory-based Bidirectional Reflectance Distribution Function (BRDF) analysis of vegetation leaves, soil, and leaf litter samples is presented. The leaf litter and soil samples, numbered 1 and 2, were obtained from a site located in the savanna biome of South Africa (Skukuza: 25.0degS, 31.5degE). A third soil sample, number 3, was obtained from Etosha Pan, Namibia (19.20degS, 15.93degE, alt. 1100 m). In addition, BRDF of local fresh and dry leaves from tulip tree (Liriodendron tulipifera) and acacia tree (Acacia greggii) were studied. It is shown how the BRDF depends on the incident and scatter angles, sample size (i.e. crushed versus whole leaf,) soil samples fraction size, sample status (i.e. fresh versus dry leaves), vegetation species (poplar versus acacia), and vegetation s biochemical composition. As a demonstration of the application of the results of this study, airborne BRDF measurements acquired with NASA's Cloud Absorption Radiometer (CAR) over the same general site where the soil and leaf litter samples were obtained are compared to the laboratory results. Good agreement between laboratory and airborne measured BRDF is reported.

  19. Methods for obtaining a uniform volume concentration of implanted ions

    International Nuclear Information System (INIS)

    Reutov, V.F.

    1995-01-01

    Three simple practical methods of irradiations with high energy particles providing the conditions for obtaining a uniform volume concentration of the implanted ions in the massive samples are described in the present paper. Realization of the condition of two-sided irradiation of a plane sample during its rotation in the flux of the projectiles is the basis of the first method. The use of free air as a filter with varying absorbent ability due to movement of the irradiated sample along ion beam brought to the atmosphere is at the basis of the second method of uniform ion alloying. The third method for obtaining a uniform volume concentration of the implanted ions in a massive sample consists of irradiation of a sample through the absorbent filter in the shape of a foil curved according to the parabolic law moving along its surface. The first method is the most effective for obtaining a great number of the samples, for example, for mechanical tests, the second one - for irradiation in different gaseous media, and the third one - for obtaining high concentrations of the implanted ions under controlled (regulated) thermal and deformation conditions. 2 refs., 7 figs

  20. A Method to Correlate mRNA Expression Datasets Obtained from Fresh Frozen and Formalin-Fixed, Paraffin-Embedded Tissue Samples: A Matter of Thresholds.

    Directory of Open Access Journals (Sweden)

    Dana A M Mustafa

    Full Text Available Gene expression profiling of tumors is a successful tool for the discovery of new cancer biomarkers and potential targets for the development of new therapeutic strategies. Reliable profiling is preferably performed on fresh frozen (FF tissues in which the quality of nucleic acids is better preserved than in formalin-fixed paraffin-embedded (FFPE material. However, since snap-freezing of biopsy materials is often not part of daily routine in pathology laboratories, one may have to rely on archival FFPE material. Procedures to retrieve the RNAs from FFPE materials have been developed and therefore, datasets obtained from FFPE and FF materials need to be made compatible to ensure reliable comparisons are possible.To develop an efficient method to compare gene expression profiles obtained from FFPE and FF samples using the same platform.Twenty-six FFPE-FF sample pairs of the same tumors representing various cancer types, and two FFPE-FF sample pairs of breast cancer cell lines, were included. Total RNA was extracted and gene expression profiling was carried out using Illumina's Whole-Genome cDNA-mediated Annealing, Selection, extension and Ligation (WG-DASL V3 arrays, enabling the simultaneous detection of 24,526 mRNA transcripts. A sample exclusion criterion was created based on the expression of 11 stably expressed reference genes. Pearson correlation at the probe level was calculated for paired FFPE-FF, and three cut-off values were chosen. Spearman correlation coefficients between the matched FFPE and FF samples were calculated for three probe lists with varying levels of significance and compared to the correlation based on all measured probes. Unsupervised hierarchical cluster analysis was performed to verify performance of the included probe lists to compare matched FPPE-FF samples.Twenty-seven FFPE-FF pairs passed the sample exclusion criterion. From the profiles of 27 FFPE and FF matched samples, the best correlating probes were identified

  1. Power and Sample Size Calculations for Logistic Regression Tests for Differential Item Functioning

    Science.gov (United States)

    Li, Zhushan

    2014-01-01

    Logistic regression is a popular method for detecting uniform and nonuniform differential item functioning (DIF) effects. Theoretical formulas for the power and sample size calculations are derived for likelihood ratio tests and Wald tests based on the asymptotic distribution of the maximum likelihood estimators for the logistic regression model.…

  2. Experimental investigation of Lagrangian structure functions in turbulence

    DEFF Research Database (Denmark)

    Berg, Jacob; Ott, Søren; Mann, Jakob

    2009-01-01

    Lagrangian properties obtained from a particle tracking velocimetry experiment in a turbulent flow at intermediate Reynolds number are presented. Accurate sampling of particle trajectories is essential in order to obtain the Lagrangian structure functions and to measure intermittency at small...

  3. Structural and magnetic properties of FeCoC system obtained by mechanical alloying

    Energy Technology Data Exchange (ETDEWEB)

    Rincón Soler, A. I. [Universidad Tecnológica de Pereira, Fac. de Ciencias, Depto. de Física (Colombia); Rodríguez Jacobo, R. R., E-mail: rrrodriguez@uao.edu.co [Universidad Autónoma de Occidente, Fac. de Ciencias Básicas, Depto. de Física (Colombia); Medina Barreto, M. H.; Cruz-Muñoz, B. [Universidad Tecnológica de Pereira, Fac. de Ciencias, Depto. de Física (Colombia)

    2017-11-15

    Fe{sub 96−X}Co{sub X}C{sub 4} (x = 0, 10, 20, 30, 40 at. %) alloys were obtained by mechanical alloying of Fe, C and Co powders using high-energy milling. The structural and magnetic properties of the alloy system were analyzed by X-ray diffraction, Scanning Electron Microscopy (SEM), Vibrating Sample Magnetometer (VSM) and Mössbauer Spectrometry at room temperature. The X-ray diffraction patterns showed a BCC-FeCoC structure phase for all samples, as well as a lattice parameter that slightly decreases with Co content. The saturation magnetization and coercive field were analyzed as a function of Co content. The Mössbauer spectra were fitted with a hyperfine magnetic field distribution showing the ferromagnetic behavior and the disordered character of the samples. The mean hyperfine magnetic field remained nearly constant (358 T) with Co content.

  4. Structural and magnetic properties of FeCoC system obtained by mechanical alloying

    International Nuclear Information System (INIS)

    Rincón Soler, A. I.; Rodríguez Jacobo, R. R.; Medina Barreto, M. H.; Cruz-Muñoz, B.

    2017-01-01

    Fe 96−X Co X C 4 (x = 0, 10, 20, 30, 40 at. %) alloys were obtained by mechanical alloying of Fe, C and Co powders using high-energy milling. The structural and magnetic properties of the alloy system were analyzed by X-ray diffraction, Scanning Electron Microscopy (SEM), Vibrating Sample Magnetometer (VSM) and Mössbauer Spectrometry at room temperature. The X-ray diffraction patterns showed a BCC-FeCoC structure phase for all samples, as well as a lattice parameter that slightly decreases with Co content. The saturation magnetization and coercive field were analyzed as a function of Co content. The Mössbauer spectra were fitted with a hyperfine magnetic field distribution showing the ferromagnetic behavior and the disordered character of the samples. The mean hyperfine magnetic field remained nearly constant (358 T) with Co content.

  5. Extracts Obtained from Pterocarpus angolensis DC and Ziziphus mucronata Exhibit Antiplasmodial Activity and Inhibit Heat Shock Protein 70 (Hsp70 Function

    Directory of Open Access Journals (Sweden)

    Tawanda Zininga

    2017-07-01

    Full Text Available Malaria parasites are increasingly becoming resistant to currently used antimalarial therapies, therefore there is an urgent need to expand the arsenal of alternative antimalarial drugs. In addition, it is also important to identify novel antimalarial drug targets. In the current study, extracts of two plants, Pterocarpus angolensis and Ziziphus mucronata were obtained and their antimalarial functions were investigated. Furthermore, we explored the capability of the extracts to inhibit Plasmodium falciparum heat shock protein 70 (Hsp70 function. Heat shock protein 70 (Hsp70 are molecular chaperones whose function is to facilitate protein folding. Plasmodium falciparum the main agent of malaria, expresses two cytosol-localized Hsp70s: PfHsp70-1 and PfHsp70-z. The PfHsp70-z has been reported to be essential for parasite survival, while inhibition of PfHsp70-1 function leads to parasite death. Hence both PfHsp70-1 and PfHsp70-z are potential antimalarial drug targets. Extracts of P. angolensis and Z. mucronata inhibited the basal ATPase and chaperone functions of the two parasite Hsp70s. Furthermore, fractions of P. angolensis and Z. mucronata inhibited P. falciparum 3D7 parasite growth in vitro. The extracts obtained in the current study exhibited antiplasmodial activity as they killed P. falciparum parasites maintained in vitro. In addition, the findings further suggest that some of the compounds in P. angolensis and Z. mucronata may target parasite Hsp70 function.

  6. In situ sampling cart development engineering task plan

    International Nuclear Information System (INIS)

    DeFord, D.K.

    1995-01-01

    This Engineering Task Plan (ETP) supports the development for facility use of the next generation in situ sampling system for characterization of tank vapors. In situ sampling refers to placing sample collection devices (primarily sorbent tubes) directly into the tank headspace, then drawing tank gases through the collection devices to obtain samples. The current in situ sampling system is functional but was not designed to provide the accurate flow measurement required by today's data quality objectives (DQOs) for vapor characterization. The new system will incorporate modern instrumentation to achieve much tighter control. The next generation system will be referred to in this ETP as the New In Situ System (NISS) or New System. The report describes the current sampling system and the modifications that are required for more accuracy

  7. Adaptive sampling method in deep-penetration particle transport problem

    International Nuclear Information System (INIS)

    Wang Ruihong; Ji Zhicheng; Pei Lucheng

    2012-01-01

    Deep-penetration problem has been one of the difficult problems in shielding calculation with Monte Carlo method for several decades. In this paper, a kind of particle transport random walking system under the emission point as a sampling station is built. Then, an adaptive sampling scheme is derived for better solution with the achieved information. The main advantage of the adaptive scheme is to choose the most suitable sampling number from the emission point station to obtain the minimum value of the total cost in the process of the random walk. Further, the related importance sampling method is introduced. Its main principle is to define the importance function due to the particle state and to ensure the sampling number of the emission particle is proportional to the importance function. The numerical results show that the adaptive scheme under the emission point as a station could overcome the difficulty of underestimation of the result in some degree, and the adaptive importance sampling method gets satisfied results as well. (authors)

  8. Clinical symptoms predict concurrent social and global functioning in an early psychosis sample.

    Science.gov (United States)

    Cacciotti-Saija, Cristina; Langdon, Robyn; Ward, Philip B; Hickie, Ian B; Guastella, Adam J

    2018-04-01

    Although well established in chronic schizophrenia, the key determinants of functioning remain unknown during the early phase of a psychotic disorder. The aim of this study was to comprehensively examine the social cognitive, basic neurocognitive and clinical predictors of concurrent social functioning and global functioning in an early psychosis sample. This study examined the relationship between social cognition, basic neurocognition and clinical symptoms with concurrent functioning in 51 early psychosis individuals. Assessments included a range of self-report, observational and clinician-rated measures of cognitive, symptom severity and functioning domains. Results revealed a significant association between self-reported social function and lower levels of both social interaction anxiety and negative psychotic symptoms. A significant association was also observed between lower levels of negative psychotic symptoms and observed social functioning. Lastly, results demonstrated a significant association between reduced negative psychotic symptoms and clinician-rated global functioning. Clinical domains such as negative symptoms and social interaction anxiety significantly contribute to an optimal model predicting outcome during the early phase of a psychotic disorder. These clinical features may also provide useful markers of an individual's capacity for social participation. Clinical implications include the need for early targeted intervention to address social anxiety and negative psychotic symptoms to facilitate optimum patient outcome. © 2015 Wiley Publishing Asia Pty Ltd.

  9. Support vector regression to predict porosity and permeability: Effect of sample size

    Science.gov (United States)

    Al-Anazi, A. F.; Gates, I. D.

    2012-02-01

    Porosity and permeability are key petrophysical parameters obtained from laboratory core analysis. Cores, obtained from drilled wells, are often few in number for most oil and gas fields. Porosity and permeability correlations based on conventional techniques such as linear regression or neural networks trained with core and geophysical logs suffer poor generalization to wells with only geophysical logs. The generalization problem of correlation models often becomes pronounced when the training sample size is small. This is attributed to the underlying assumption that conventional techniques employing the empirical risk minimization (ERM) inductive principle converge asymptotically to the true risk values as the number of samples increases. In small sample size estimation problems, the available training samples must span the complexity of the parameter space so that the model is able both to match the available training samples reasonably well and to generalize to new data. This is achieved using the structural risk minimization (SRM) inductive principle by matching the capability of the model to the available training data. One method that uses SRM is support vector regression (SVR) network. In this research, the capability of SVR to predict porosity and permeability in a heterogeneous sandstone reservoir under the effect of small sample size is evaluated. Particularly, the impact of Vapnik's ɛ-insensitivity loss function and least-modulus loss function on generalization performance was empirically investigated. The results are compared to the multilayer perception (MLP) neural network, a widely used regression method, which operates under the ERM principle. The mean square error and correlation coefficients were used to measure the quality of predictions. The results demonstrate that SVR yields consistently better predictions of the porosity and permeability with small sample size than the MLP method. Also, the performance of SVR depends on both kernel function

  10. Obtaining zircaloy powder through hydriding

    International Nuclear Information System (INIS)

    Dupim, Ivaldete da Silva; Moreira, Joao M.L.

    2009-01-01

    Zirconium alloys are good options for the metal matrix in dispersion fuels for power reactors due to their low thermal neutron absorption cross-section, good corrosion resistance, good mechanical strength and high thermal conductivity. A necessary step for obtaining such fuels is producing Zr alloy powder for the metal matrix composite material. This article presents results from the Zircaloy-4 hydrogenation tests with the purpose to embrittle the alloy as a first step for comminuting. Several hydrogenation tests were performed and studied through thermogravimetric analysis. They included H 2 pressures of 25 and 50 kPa and temperatures ranging between from 20 to 670 deg C. X-ray diffraction analysis showed in the hydrogenated samples the predominant presence of ZrH 2 and some ZrO 2 . Some kinetics parameters for the Zircaloy-4 hydrogenation reaction were obtained: the time required to reach the equilibrium state at the dwell temperature was about 100 minutes; the hydrogenation rate during the heating process from 20 to 670 deg C was about 21 mg/h, and at constant temperature of 670 deg C, the hydride rate was about 1.15 mg/h. The hydrogenation rate is largest during the heating process and most of it occurs during this period. After hydrogenated, the samples could easily be comminuted indicating that this is a possible technology to obtain Zircaloy powder. The results show that only few minutes of hydrogenation are necessary to reach the hydride levels required for comminuting the Zircaloy. The final hydride stoichiometry was between 2.7 and 2.8 H for each Zr atom in the sample (author)

  11. Synthesis of polydopamine-functionalized magnetic graphene and carbon nanotubes hybrid nanocomposites as an adsorbent for the fast determination of 16 priority polycyclic aromatic hydrocarbons in aqueous samples.

    Science.gov (United States)

    Chen, Kun; Jin, Rongrong; Luo, Chen; Song, Guoxin; Hu, Yaoming; Cheng, Hefa

    2018-04-01

    A novel adsorbent made of polydopamine-functionalized magnetic graphene and carbon nanotubes hybrid nanocomposite was synthesized and applied to determine 16 priority polycyclic aromatic hydrocarbons by magnetic solid phase extraction in water samples. FTIR spectroscopy, transmission electron microscopy, scanning electron microscopy, and Raman spectroscopy consistently indicate that the synthesized adsorbents are made of core-shell nanoparticles well dispersed on the surface of graphene and carbon nanotubes. The major factors affecting the extraction efficiency, including the pH value of samples, the amount of adsorbent, adsorption time and desorption time, type and volume of desorption solvent, were systematically optimized. Under the optimum extraction conditions, a linear response was obtained for polycyclic aromatic hydrocarbons between concentrations of 10 and 500 ng/L with the correlation coefficients ranging from 0.9958 to 0.9989, and the limits of detection (S/N = 3) were between 0.1 and 3.0 ng/L. Satisfactory results were also obtained when applying these magnetic graphene/carbon nanotubes/polydopamine hybrid nanocomposites to detect polycyclic aromatic hydrocarbons in several environmental aqueous samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Histology of periapical lesions obtained during apical surgery.

    Science.gov (United States)

    Schulz, Malte; von Arx, Thomas; Altermatt, Hans Jörg; Bosshardt, Dieter

    2009-05-01

    The aim of this was to evaluate the histology of periapical lesions in teeth treated with periapical surgery. After root-end resection, the root tip was removed together with the periapical pathological tissue. Histologic sectioning was performed on calcified specimens embedded in methylmethacrylate (MMA) and on demineralized specimens embedded in LR White (Fluka, Buchs, Switzerland). The samples were evaluated with light and transmission electron microscopy (TEM). The histologic findings were classified into periapical abscesses, granulomas, or cystic lesions (true or pocket cysts). The final material comprised 70% granulomas, 23% cysts and 5% abscesses, 1% scar tissues, and 1% keratocysts. Six of 125 samples could not be used. The cystic lesions could not be subdivided into pocket or true cysts. All cysts had an epithelium-lined cavity, two of them with cilia-lined epithelium. These results show the high incidence of periapical granulomas among periapical lesions obtained during apical surgery. Periapical abscesses were a rare occasion. The histologic findings from samples obtained during apical surgery may differ from findings obtained by teeth extractions. A determination between pocket and true apical cysts is hardly possible when collecting samples by apical surgery.

  13. Exploring the Relationship between Family Functioning and Psycho-Pathology in a Sample in the Pediatric Age.

    Science.gov (United States)

    Pepe, Silvia; Tortolani, Daniela; Gentile, Simonetta; Di Ciommo, Vincenzo M

    2015-03-17

    The purpose of this study was to investigate differences in family functioning between families with clinical subjects in paediatric age and families taken from the Italian population. To this aim we used the Family Adaptability and Cohesion Evaluation Scale (FACES). Participants were children diagnosed with a psychopathology, recruited into the psychiatry department in a Paediatric Hospital of Rome. A total of 106 families participated in the study. The non-pathological sample is composed by 2,543 parents in different age periods of the life-cycle. Results showed significant differences in family functioning between pathological and non-pathological samples. Specifically, families from the pathological sample (particularly the ones who experienced eating disorders) were more frequently located in extreme or mid-range regions of Olson's circumplex model (p families in a clinical setting. Critical aspects and clinical applications are discussed.

  14. The application of statistical and/or non-statistical sampling techniques by internal audit functions in the South African banking industry

    Directory of Open Access Journals (Sweden)

    D.P. van der Nest

    2015-03-01

    Full Text Available This article explores the use by internal audit functions of audit sampling techniques in order to test the effectiveness of controls in the banking sector. The article focuses specifically on the use of statistical and/or non-statistical sampling techniques by internal auditors. The focus of the research for this article was internal audit functions in the banking sector of South Africa. The results discussed in the article indicate that audit sampling is still used frequently as an audit evidence-gathering technique. Non-statistical sampling techniques are used more frequently than statistical sampling techniques for the evaluation of the sample. In addition, both techniques are regarded as important for the determination of the sample size and the selection of the sample items

  15. Dietary inflammatory index and memory function: population-based national sample of elderly Americans.

    Science.gov (United States)

    Frith, Emily; Shivappa, Nitin; Mann, Joshua R; Hébert, James R; Wirth, Michael D; Loprinzi, Paul D

    2018-03-01

    The objective of this study was to examine the association between dietary inflammatory potential and memory and cognitive functioning among a representative sample of the US older adult population. Cross-sectional data from the 2011-2012 and 2013-2014 National Health and Nutrition Examination Survey were utilised to identify an aggregate sample of adults 60-85 years of age (n 1723). Dietary inflammatory index (DII®) scores were calculated using 24-h dietary recall interviews. Three memory-related assessments were employed, including the Consortium to Establish a Registry for Alzheimer's disease (CERAD) Word Learning subset, the Animal Fluency test and the Digit Symbol Substitution Test (DSST). Inverse associations were observed between DII scores and the different memory parameters. Episodic memory (CERAD) (b adjusted=-0·39; 95 % CI -0·79, 0·00), semantic-based memory (Animal Fluency Test) (b adjusted=-1·18; 95 % CI -2·17, -0·20) and executive function and working-memory (DSST) (b adjusted=-2·80; 95 % CI -5·58, -0·02) performances were lowest among those with the highest mean DII score. Though inverse relationships were observed between DII scores and memory and cognitive functioning, future work is needed to further explore the neurobiological mechanisms underlying the complex relationship between inflammation-related dietary behaviour and memory and cognition.

  16. Surface correlation function analysis of high resolution scattering data from mirrored surfaces obtained using a triple-axis X-ray diffractometer

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; Schnopper, H. W.

    1988-01-01

    methods is that they are bandwidth-limited. A crucial point in the analysis of data is, therefore, to specify accurately the wavelength bandwidth limitation and to determine the surface autocorrelation function within this bandwidth. The authors present a number of scattering measurements obtained using...... a triple-axis perfect-crystal X-ray diffractometer and the results of an autocorrelation function analysis. Furthermore, they present some measurements of integrated reflectivity, which they believe provide evidence for microroughness in the range from a few angstroms to tens of microns...

  17. A time-frequency analysis method to obtain stable estimates of magnetotelluric response function based on Hilbert-Huang transform

    Science.gov (United States)

    Cai, Jianhua

    2017-05-01

    The time-frequency analysis method represents signal as a function of time and frequency, and it is considered a powerful tool for handling arbitrary non-stationary time series by using instantaneous frequency and instantaneous amplitude. It also provides a possible alternative to the analysis of the non-stationary magnetotelluric (MT) signal. Based on the Hilbert-Huang transform (HHT), a time-frequency analysis method is proposed to obtain stable estimates of the magnetotelluric response function. In contrast to conventional methods, the response function estimation is performed in the time-frequency domain using instantaneous spectra rather than in the frequency domain, which allows for imaging the response parameter content as a function of time and frequency. The theory of the method is presented and the mathematical model and calculation procedure, which are used to estimate response function based on HHT time-frequency spectrum, are discussed. To evaluate the results, response function estimates are compared with estimates from a standard MT data processing method based on the Fourier transform. All results show that apparent resistivities and phases, which are calculated from the HHT time-frequency method, are generally more stable and reliable than those determined from the simple Fourier analysis. The proposed method overcomes the drawbacks of the traditional Fourier methods, and the resulting parameter minimises the estimation bias caused by the non-stationary characteristics of the MT data.

  18. Blocking temperature distribution in implanted Co-Ni nanoparticles obtained by magneto-optical measurements

    Energy Technology Data Exchange (ETDEWEB)

    D' Orazio, F.; Lucari, F. E-mail: franco.lucari@aquila.infn.it; Melchiorri, M.; Julian Fernandez, C. de; Mattei, G.; Mazzoldi, P.; Sangregorio, C.; Gatteschi, D.; Fiorani, D

    2003-05-01

    Three samples of Co-Ni alloy nanoparticles with different compositions were prepared by sequential ion implantation in silica slides. Transmission electron microscopy (TEM) showed the presence of spherical nanoparticles dispersed in the matrix. Magneto-optical Kerr effect analysis identified two magnetic components attributed to superparamagnetic particles in unblocked and blocked states, respectively. Magnetic field loops were measured as a function of temperature. Blocking temperature distributions were obtained; and their comparison with the size distributions derived from TEM provided the average magnetic anisotropy of the particles.

  19. Blocking temperature distribution in implanted Co-Ni nanoparticles obtained by magneto-optical measurements

    International Nuclear Information System (INIS)

    D'Orazio, F.; Lucari, F.; Melchiorri, M.; Julian Fernandez, C. de; Mattei, G.; Mazzoldi, P.; Sangregorio, C.; Gatteschi, D.; Fiorani, D.

    2003-01-01

    Three samples of Co-Ni alloy nanoparticles with different compositions were prepared by sequential ion implantation in silica slides. Transmission electron microscopy (TEM) showed the presence of spherical nanoparticles dispersed in the matrix. Magneto-optical Kerr effect analysis identified two magnetic components attributed to superparamagnetic particles in unblocked and blocked states, respectively. Magnetic field loops were measured as a function of temperature. Blocking temperature distributions were obtained; and their comparison with the size distributions derived from TEM provided the average magnetic anisotropy of the particles

  20. Ceratonia siliqua L. hydroethanolic extract obtained by ultrasonication: antioxidant activity, phenolic compounds profile and effects in yogurts functionalized with their free and microencapsulated forms.

    Science.gov (United States)

    Rached, Irada; Barros, Lillian; Fernandes, Isabel P; Santos-Buelga, Celestino; Rodrigues, Alírio E; Ferchichi, Ali; Barreiro, Maria Filomena; Ferreira, Isabel C F R

    2016-03-01

    Bioactive extracts were obtained from powdered carob pulp through an ultrasound extraction process and then evaluated in terms of antioxidant activity. Ten minutes of ultrasonication at 375 Hz were the optimal conditions leading to an extract with the highest antioxidant effects. After its chemical characterization, which revealed the preponderance of gallotannins, the extract (free and microencapsulated) was incorporated in yogurts. The microspheres were prepared using an extract/sodium alginate ratio of 100/400 (mg mg(-1)) selected after testing different ratios. The yogurts with the free extract exhibited higher antioxidant activity than the samples added with the encapsulated extracts, showing the preserving role of alginate as a coating material. None of the forms significantly altered the yogurt's nutritional value. This study confirmed the efficiency of microencapsulation to stabilize functional ingredients in food matrices maintaining almost the structural integrity of polyphenols extracted from carob pulp and furthermore improving the antioxidant potency of the final product.

  1. Antigenic fractions from Taenia crassiceps metacestodes obtained by hydrophobicity for the immunodiagnosis of active and inactive forms of neurocysticercosis in human cerebrospinal fluid samples.

    Science.gov (United States)

    da Silva, Gabriela B; Nunes, Daniela S; de Sousa, José Eduardo N; Gonçalves-Pires, Maria do R F; Levenhagen, Marcelo A; Costa-Cruz, Julia M

    2017-04-01

    This study aimed to evaluate the total extract of Taenia crassiceps metacestodes (TC) and its antigenic fractions obtained by Triton X-114 fractionation techniques, such as detergent (DC) and aqueous (AC), in the immunodiagnosis of human neurocysticercosis (NCC). Cerebrospinal fluid samples were divided into two groups: Group 1 (n=40), which was further divided into active (n=20) and inactive (n=20) NCC, and Group 2 (control group), which comprised 39 CSF samples from patients who had another neurological disorder, were suffering from other infectious diseases of the brain or had other parasitic infections. The total extracts and antigenic fractions were tested by enzyme-linked immunosorbent assay (ELISA) to detect human IgG anti-Taenia solium. T. crassiceps fractions (DC and AC) showed the same value of sensitivity (Se), 100%, for active and inactive NCC and a specificity (Sp) of 97.4%. The DS fraction obtained from T. solium showed 100% Se for active NCC, 95% Se for inactive NCC and a 92.3% Sp. The AS fraction obtained from T. solium showed 100% Se for both active and inactive NCC and a 94.9% Sp. There was a positive correlation between the total saline extract of T. crassiceps (TC) and T. solium (TS) and their fractions (DC, AC, DS and AS). Positive predictive value, negative predictive value, diagnostic efficiency and Youden index were calculated. In conclusion, these results demonstrated that detergent and aqueous fractions obtained from T. crassiceps metacestodes are important sources of specific antigens and are efficient for immunodiagnosis of active and inactive NCC. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  2. Rate-distortion optimization for compressive video sampling

    Science.gov (United States)

    Liu, Ying; Vijayanagar, Krishna R.; Kim, Joohee

    2014-05-01

    The recently introduced compressed sensing (CS) framework enables low complexity video acquisition via sub- Nyquist rate sampling. In practice, the resulting CS samples are quantized and indexed by finitely many bits (bit-depth) for transmission. In applications where the bit-budget for video transmission is constrained, rate- distortion optimization (RDO) is essential for quality video reconstruction. In this work, we develop a double-level RDO scheme for compressive video sampling, where frame-level RDO is performed by adaptively allocating the fixed bit-budget per frame to each video block based on block-sparsity, and block-level RDO is performed by modelling the block reconstruction peak-signal-to-noise ratio (PSNR) as a quadratic function of quantization bit-depth. The optimal bit-depth and the number of CS samples are then obtained by setting the first derivative of the function to zero. In the experimental studies the model parameters are initialized with a small set of training data, which are then updated with local information in the model testing stage. Simulation results presented herein show that the proposed double-level RDO significantly enhances the reconstruction quality for a bit-budget constrained CS video transmission system.

  3. Research on self-absorption corrections for laboratory γ spectral analysis of soil samples

    International Nuclear Information System (INIS)

    Tian Zining; Jia Mingyan; Li Huibin; Cheng Ziwei; Ju Lingjun; Shen Maoquan; Yang Xiaoyan; Yan Ling; Fen Tiancheng

    2010-01-01

    Based on the calibration results of the point sources,dimensions of HPGe crystal were characterized.Linear attenuation coefficients and detection efficiencies of all kinds of samples were calculated,and the function F(μ) of φ75 mm x 25 mm sample was established. Standard surface source was used to simulate the source of different heights in the soil sample. And the function ε(h) which reflect the relationship between detection efficiencies and heights of the surface sources was determined. The detection efficiency of calibration source can be obtained by integration, F(μ) functions of soil samples established is consistent with the result of MCNP calculation code. Several φ75 mm x 25 mm soil samples were measured by the HPGe spectrometer,and the function F(μ) was used to correct the self absorption. F(μ) functions of soil samples of various dimensions can be calculated by MCNP calculation code established, and self absorption correction can be done. To verify the efficiency of calculation results, φ75 mm x 75 mm soil samples were measured. Several φ75 mm x 25 mm soil samples from aerosphere nuclear testing field was measured by the HPGe spectrometer,and the function F(μ) was used to correct the self absorption. The function F(m) was established, and the technical method which is used to correct the soil samples of unknown area is also given. The correction method of surface source greatly improves the gamma spectrum's metrical accuracy, and it will be widely applied to environmental radioactive investigation. (authors)

  4. Obtaining reliable Likelihood Ratio tests from simulated likelihood functions

    DEFF Research Database (Denmark)

    Andersen, Laura Mørch

    It is standard practice by researchers and the default option in many statistical programs to base test statistics for mixed models on simulations using asymmetric draws (e.g. Halton draws). This paper shows that when the estimated likelihood functions depend on standard deviations of mixed param...

  5. Mesostructured Au/C materials obtained by replication of functionalized SBA-15 silica containing highly dispersed gold nanoparticles

    KAUST Repository

    Kerdi, Fatmé

    2011-04-01

    The preparation and characterization of highly dispersed gold nanoparticles in ordered mesoporous carbons CMK-3 are reported. These carbons were obtained using gold-containing functionalized SBA-15 silicas as hard templates. Two series of Au/SiO2 templates were prepared, depending on the nature of the functionalization molecule. While ammonium-functionalized silicas gave gold particles with a size determined by the pores of the silica support, the use of mercaptopropyltrimethoxysilane as grafting molecule afforded the possibility to control the particle size inside the mesopores. Both series gave highly ordered mesoporous carbons with gold particles incorporated in the carbon nanorods. However, the gold particle size in mesoporous carbons was the same for both series and apparently did not depend on the nature of the silica template. Both Au/SiO2 templates and their corresponding Au/CMK-3 materials have been characterized by X-ray diffraction, nitrogen adsorption/desorption, chemical analysis, solid-state nuclear magnetic resonance and transmission electron microscopy. They were also used as catalysts in the aerobic oxidation of cyclohexene and trans-stilbene in the liquid phase. © 2010 Elsevier Inc. All rights reserved.

  6. Characterization of the March 2017 Tank 15 Waste Removal Slurry Sample (Combination of Slurry Samples HTF-15-17-28 and HTF-15-17-29)

    Energy Technology Data Exchange (ETDEWEB)

    Reboul, S. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); King, W. D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Coleman, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-05-09

    Two March 2017 Tank 15 slurry samples (HTF-15-17-28 and HTF-15-17-29) were collected during the second bulk waste removal campaign and submitted to SRNL for characterization. At SRNL, the two samples were combined and then characterized by a series of physical, elemental, radiological, and ionic analysis methods. Sludge settling as a function of time was also quantified. The characterization results reported in this document are consistent with expectations based upon waste type, process knowledge, comparisons between alternate analysis techniques, and comparisons with the characterization results obtained for the November 2016 Tank 15 slurry sample (the sample collected during the first bulk waste removal campaign).

  7. The Effect of Asymmetrical Sample Training on Retention Functions for Hedonic Samples in Rats

    Science.gov (United States)

    Simmons, Sabrina; Santi, Angelo

    2012-01-01

    Rats were trained in a symbolic delayed matching-to-sample task to discriminate sample stimuli that consisted of the presence of food or the absence of food. Asymmetrical sample training was provided in which one group was initially trained with only the food sample and the other group was initially trained with only the no-food sample. In…

  8. Roseomonas tokyonensis sp. nov. isolated from a biofilm sample obtained from a cooling tower in Tokyo, Japan.

    Science.gov (United States)

    Furuhata, Katsunori; Ishizaki, Naoto; Edagawa, Akiko; Fukuyama, Masafumi

    2013-01-01

    Strain K-20(T), a Gram-negative, nonmotile, nonspore-forming and strictly aerobic coccobacillus, which produces a pale pink pigment (R2A agar medium, 30℃, seven days) was isolated from a sample of biofilm obtained from a cooling tower in Tokyo, Japan. A phylogenetic analysis of the 16S rRNA partial gene sequences (1,439 bp) showed that the strain (accession number: AB297501) was related to Roseomonas frigidaquae CW67(T) and Roseomonas stagni HS-69(T) with 97.4% and 96.9% sequence similarity, respectively. Strain K-20(T) formed a distinct cluster with Roseomonas frigidaquae CW67(T) in the phylogenetic tree at a high bootstrap value (93%); however, distance was recognized between the strains. In addition, the DNA-DNA hybridization level between strain K-20(T) and Roseomonas frigidaquae JCM 15073(T) was 33%. The taxonomic data indicate that K-20(T) (=JCM 14634(T) =KCTC 32152(T)) should be classified in the genus Roseomonas as the type strain of a novel species, Roseomonas tokyonensis sp. nov.

  9. Robust functional statistics applied to Probability Density Function shape screening of sEMG data.

    Science.gov (United States)

    Boudaoud, S; Rix, H; Al Harrach, M; Marin, F

    2014-01-01

    Recent studies pointed out possible shape modifications of the Probability Density Function (PDF) of surface electromyographical (sEMG) data according to several contexts like fatigue and muscle force increase. Following this idea, criteria have been proposed to monitor these shape modifications mainly using High Order Statistics (HOS) parameters like skewness and kurtosis. In experimental conditions, these parameters are confronted with small sample size in the estimation process. This small sample size induces errors in the estimated HOS parameters restraining real-time and precise sEMG PDF shape monitoring. Recently, a functional formalism, the Core Shape Model (CSM), has been used to analyse shape modifications of PDF curves. In this work, taking inspiration from CSM method, robust functional statistics are proposed to emulate both skewness and kurtosis behaviors. These functional statistics combine both kernel density estimation and PDF shape distances to evaluate shape modifications even in presence of small sample size. Then, the proposed statistics are tested, using Monte Carlo simulations, on both normal and Log-normal PDFs that mimic observed sEMG PDF shape behavior during muscle contraction. According to the obtained results, the functional statistics seem to be more robust than HOS parameters to small sample size effect and more accurate in sEMG PDF shape screening applications.

  10. A fully blanketed early B star LTE model atmosphere using an opacity sampling technique

    International Nuclear Information System (INIS)

    Phillips, A.P.; Wright, S.L.

    1980-01-01

    A fully blanketed LTE model of a stellar atmosphere with Tsub(e) = 21914 K (thetasub(e) = 0.23), log g = 4 is presented. The model includes an explicit representation of the opacity due to the strongest lines, and uses a statistical opacity sampling technique to represent the weaker line opacity. The sampling technique is subjected to several tests and the model is compared with an atmosphere calculated using the line-distribution function method. The limitations of the distribution function method and the particular opacity sampling method used here are discussed in the light of the results obtained. (author)

  11. GANSEKI: JAMSTEC Deep Seafloor Rock Sample Database Emerging to the New Phase

    Science.gov (United States)

    Tomiyama, T.; Ichiyama, Y.; Horikawa, H.; Sato, Y.; Soma, S.; Hanafusa, Y.

    2013-12-01

    Japan Agency for Marine-Earth Science and Technology (JAMSTEC) collects a lot of substantial samples as well as various geophysical data using its research vessels and submersibles. These samples and data, which are obtained by spending large amounts of human and physical resources, are precious wealth of the world scientific community. For the better use of these samples and data, it is important that they are utilized not only for initial purpose of each cruse but also for other general scientific and educational purposes of second-hand users. Based on the JAMSTEC data and sample handling policies [1], JAMSTEC has systematically stored samples and data obtained during research cruises, and provided them to domestic/foreign activities on research, education, and public relation. Being highly valued for second-hand usability, deep seafloor rock samples are one of the most important types of samples obtained by JAMSTEC, as oceanic biological samples and sediment core samples are. Rock samples can be utilized for natural history sciences and other various purposes; some of these purposes are connected to socially important issues such as earthquake mechanisms and mineral resource developments. Researchers and educators can access to JAMSTEC rock samples and associated data through 'GANSEKI [2]', the JAMSTEC Deep Seafloor Rock Sample Database. GANSEKI was established on the Internet in 2006 and its contents and functions have been continuously enriched and upgraded since then. GANSEKI currently provides 19 thousands of sample metadata, 9 thousands of collection inventory data and 18 thousands of geochemical data. Most of these samples are recovered from the North-western Pacific Ocean, although samples from other area are also included. The major update of GANSEKI held in May 2013 involved a replacement of database core system and a redesign of user interface. In the new GANSEKI, users can select samples easily and precisely using multi-index search, numerical

  12. Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)

    International Nuclear Information System (INIS)

    Lawton, J J; Pulisciano, A; Palmer, R E

    2009-01-01

    Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

  13. Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)

    Energy Technology Data Exchange (ETDEWEB)

    Lawton, J J; Pulisciano, A; Palmer, R E, E-mail: R.E.Palmer@bham.ac.u [Nanoscale Physics Research Laboratory, School of Physics and Astronomy, University of Birmingham, Birmingham B15 2TT (United Kingdom)

    2009-11-25

    Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

  14. Fetal functional brain age assessed from universal developmental indices obtained from neuro-vegetative activity patterns.

    Directory of Open Access Journals (Sweden)

    Dirk Hoyer

    Full Text Available Fetal brain development involves the development of the neuro-vegetative (autonomic control that is mediated by the autonomic nervous system (ANS. Disturbances of the fetal brain development have implications for diseases in later postnatal life. In that context, the fetal functional brain age can be altered. Universal principles of developmental biology applied to patterns of autonomic control may allow a functional age assessment. The work aims at the development of a fetal autonomic brain age score (fABAS based on heart rate patterns. We analysed n = 113 recordings in quiet sleep, n = 286 in active sleep, and n = 29 in active awakeness from normals. We estimated fABAS from magnetocardiographic recordings (21.4-40.3 weeks of gestation preclassified in quiet sleep (n = 113, 63 females and active sleep (n = 286, 145 females state by cross-validated multivariate linear regression models in a cross-sectional study. According to universal system developmental principles, we included indices that address increasing fluctuation range, increasing complexity, and pattern formation (skewness, power spectral ratio VLF/LF, pNN5. The resulting models constituted fABAS. fABAS explained 66/63% (coefficient of determination R(2 of training and validation set of the variance by age in quiet, while 51/50% in active sleep. By means of a logistic regression model using fluctuation range and fetal age, quiet and active sleep were automatically reclassified (94.3/93.1% correct classifications. We did not find relevant gender differences. We conclude that functional brain age can be assessed based on universal developmental indices obtained from autonomic control patterns. fABAS reflect normal complex functional brain maturation. The presented normative data are supplemented by an explorative study of 19 fetuses compromised by intrauterine growth restriction. We observed a shift in the state distribution towards active awakeness. The lower WGA

  15. Functionalized Raspberry-Like Microparticles obtained by Assembly of Nanoparticles during Electrospraying

    International Nuclear Information System (INIS)

    Cho, Eun Chul; Jeong, Unyong; Hwang, Yoon Kyun

    2014-01-01

    The present study suggests a novel method to produce raspberry-like microparticles containing diverse functional materials inside. The raspberry-like microparticles were produced from a random assembly of uniformly-sized poly(methyl methacrylate) (PMMA) nanoparticles via electrospraying. The solution containing the PMMA nanoparticles were supplied through the inner nozzle and compressed air was emitted through the outer nozzle. The air supply helped fast evaporation of acetone, so it enabled copious amount of microparticles as dry powder. The microparticles were highly porous both on the surface and interiors, hence various materials with a function of UV-blocking (TiO 2 nanoparticles and methoxyphenyl triazine) or anti-aging (ethyl(4-(2,3-dihydro-1H-indene-5-carboxyamido) benzoate)) were loaded in large amount (17 wt % versus PMMA). The surface and interior structures of the microparticles were dependent on the characteristics of functional materials. The results clearly suggest that the process to prepare the raspberry-like microparticles can be an excellent approach to generate functional microstructures

  16. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  17. The influence of technological parameters on the dynamic behavior of "liquid wood" samples obtained by injection molding

    Science.gov (United States)

    Plavanescu Mazurchevici, Simona; Carausu, Constantin; Comaneci, Radu; Nedelcu, Dumitru

    2017-10-01

    The plastic products contribute to environmental pollution. Replacing the plastic materials with biodegradable materials with superior properties is an absolute necessity and important research direction for the near future. The first steps in this regard were the creation of composite materials containing natural fibers with positive effects on the environment that have penetrated in different fields. The bioplastics and biocomposites made from natural fibers is a topical solution. The next step was made towards obtaining biodegradable and recyclable materials based on cellulose, lignin and no carcinogens. In this category fall the "liquid wood" with a use up to five times without affecting the mechanical properties. "Liquid wood" is a high quality thermoplastic biocomposite. "Liquid wood" is a biopolymer composite divided in three categories, ARBOFORM®, ARBOBLEND® and ARBOFILL®, which have differed composition in terms of lignin percentage, being delivered by Tecnaro, as granules, [1]. The paper's research was focus on Arboform L V3 Nature and Arboform L V3 Nature reinforced with aramid fiber. In the experimental plan were taken into account six parameters (Dinj - direction of injection [°]; Ttop - melting temperature [°C]; Pinj - injection pressure [MPa] Ss - speed [m/min]; tinj - injection time [s] and tc - cooling time [s]) each with two levels, research carried on by Taguchi methodology. Processing Taguchi method allowed both Taguchi setting work parameters influence on storage modulus and damping as the size and influence their ranking. Experimental research concerning the influence technological parameters on storage modulus of samples obtained by injection from Arboform L V3 Nature yielded an average of 6055MPa and descending order as follows: Trac, Ss, Pinj, Dinj and Ttop. The average of model for reinforced material was 6419MPa and descending order of parameters influence such as: Dinj, Trac, Ttop, tinj, Ss and Pinj.

  18. Synthesis of magnetite nanoparticles obtained by the thermal decomposition method

    International Nuclear Information System (INIS)

    Fonseca, Renilma de Sousa Pinheiro; Sinfronio, Francisco Savio Mendes; Menezes, Alan Silva de; Sharma, Surender Kumar; Silva, Fernando Carvalho; Moscoso-Londono, Oscar; Muraca, Diego; Knobel, Marcelo

    2016-01-01

    Full text: Magnetite nanoparticles have found numerous applications in biomedicine such as magnetic separation, drug delivery, magnetic resonance imaging (MRI) and hyperthermia agents [1]. These features are related to their superparamagnetic behavior, low toxicity and high functionalization [2]. Thus, this work aims to obtain oleylamine-coated magnetite nanoparticles by means of thermal decomposition method at different temperatures and reaction time. All samples were characterized by FTIR, XRD and SQUID magnetometer. The infrared spectra showed two vibrational modes at 2920 and 2850 cm -1 , assigned to the asymmetrical and symmetrical stretching of C-H groups of the oleic acid and oleylamine, respectively. The XRD pattern of the samples confirmed the formation of magnetite phase (ICSD 36314) at all temperatures. The average size of the crystallites was determined by Debye-Scherrer equation with values in the range of 1.1-1.5 nm. Field-cooled and zero field-cooled analysis demonstrate that the blocking temperature (T B ) is below room temperature in all cases, indicating that all magnetite nanoparticles are superparamagnetic at room temperature and ferrimagnetic at low temperature. (author)

  19. Synthesis of magnetite nanoparticles obtained by the thermal decomposition method

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Renilma de Sousa Pinheiro; Sinfronio, Francisco Savio Mendes; Menezes, Alan Silva de; Sharma, Surender Kumar; Silva, Fernando Carvalho, E-mail: renilma.ufma@gmail.com [Universidade Federal do Maranhao (UFMA), Sao Luis, MA (Brazil); Moscoso-Londono, Oscar; Muraca, Diego; Knobel, Marcelo [Universidade Estadual de Campinas (UNICAMP), SP (Brazil)

    2016-07-01

    Full text: Magnetite nanoparticles have found numerous applications in biomedicine such as magnetic separation, drug delivery, magnetic resonance imaging (MRI) and hyperthermia agents [1]. These features are related to their superparamagnetic behavior, low toxicity and high functionalization [2]. Thus, this work aims to obtain oleylamine-coated magnetite nanoparticles by means of thermal decomposition method at different temperatures and reaction time. All samples were characterized by FTIR, XRD and SQUID magnetometer. The infrared spectra showed two vibrational modes at 2920 and 2850 cm{sup -1}, assigned to the asymmetrical and symmetrical stretching of C-H groups of the oleic acid and oleylamine, respectively. The XRD pattern of the samples confirmed the formation of magnetite phase (ICSD 36314) at all temperatures. The average size of the crystallites was determined by Debye-Scherrer equation with values in the range of 1.1-1.5 nm. Field-cooled and zero field-cooled analysis demonstrate that the blocking temperature (T{sub B}) is below room temperature in all cases, indicating that all magnetite nanoparticles are superparamagnetic at room temperature and ferrimagnetic at low temperature. (author)

  20. Obtaining macroscopic quantities for the contact line problem from Density Functional Theory using asymptotic methods

    Science.gov (United States)

    Sibley, David; Nold, Andreas; Kalliadasis, Serafim

    2015-11-01

    Density Functional Theory (DFT), a statistical mechanics of fluids approach, captures microscopic details of the fluid density structure in the vicinity of contact lines, as seen in computations in our recent study. Contact lines describe the location where interfaces between two fluids meet solid substrates, and have stimulated a wealth of research due to both their ubiquity in nature and technological applications and also due to their rich multiscale behaviour. Whilst progress can be made computationally to capture the microscopic to mesoscopic structure from DFT, complete analytical results to fully bridge to the macroscale are lacking. In this work, we describe our efforts to bring asymptotic methods to DFT to obtain results for contact angles and other macroscopic quantities in various parameter regimes. We acknowledge financial support from European Research Council via Advanced Grant No. 247031.

  1. Metagenomics as a tool to obtain full genomes of process-critical bacteria in engineered systems

    DEFF Research Database (Denmark)

    Albertsen, Mads; Hugenholtz, Philip; Tyson, Gene W.

    of the community. The assembled genomes include many of the process-critical bacteria involved in wastewater treatment, such as Competibacter, Tetrasphaera and TM7. The approach is not limited to different extraction methods, but can be applied to any treatment that results in different relative abundance......Bacteria play a pivotal role in engineered systems such as wastewater treatment plants. Obtaining genomes of the bacteria provides the genetic potential of the system and also allows studies of in situ functions through transcriptomics and proteomics. Hence, it enables correlations of operational......, the sequencing of bulk genomic DNA from environmental samples, has the potential to provide genomes of this uncultured majority. However, so far only few bacterial genomes have been obtained from metagenomic data. In this study we present a new approach to obtain individual genomes from metagenomes. We deeply...

  2. Possibility of obtaining reliable information on component safety by means of large-scale tensile samples with Orowan-Soete flaws

    International Nuclear Information System (INIS)

    Aurich, D.; Wobst, K.; Kafka, H.

    1984-01-01

    The aim of the paper is to review the present knowledge regarding the ability of wide plate tensile specimen with saw cut trough center flaws of providing accurate information on component reliability; it points out the advantages and disadvantages of this specimen geometries. The effect of temperature, specimen geometry, ligament size and notch radii are discussed in comparison with other specimen geometries. This is followed by a comparison of the results of such tests with tests on inside stressed tanks. Conclusions: wide-plate tensile specimen are generally appropriate for assessing welded joints. However, they result in a more favourable evaluation of low-toughness steels from the point of view of crack growth than of high-toughness and soft steels in case of stresses with incipient cracks, as compared with the results obtained with three-point bending samples. (orig.) [de

  3. Parental socioeconomic status and child intellectual functioning in a Norwegian sample.

    Science.gov (United States)

    Eilertsen, Thomas; Thorsen, Anders Lillevik; Holm, Silje Elisabeth Hasmo; Bøe, Tormod; Sørensen, Lin; Lundervold, Astri J

    2016-10-01

    Socioeconomic status (SES) in childhood has been linked to cognitive function and future academic and occupational success in studies from several countries. However, previous Nordic studies have shown inconsistent results regarding the strength of this link. We therefore investigated the association between SES and cognitive functioning in a sample of 255 Norwegian children, including 151 typically developing children and 104 children with a psychiatric diagnosis. The third edition of the Wechsler Intelligence Scale for Children (WISC-III) to assess cognitive function was used. SES was defined from maternal and paternal education and family income of typically developing children and of a subsample of children with a psychiatric diagnosis. Multiple adjusted regression analyses were used to investigate the relation between SES and cognitive functioning. The analyses showed that SES explained a significant part of the variance of the full-scale WISC-III score and two WISC-III indices (Verbal Comprehension and Freedom from Distractibility). Overall, the strength of the relations was weaker than expected from reports from other non-Nordic countries. Parental education was the only significant individual predictor, suggesting that income was of minor importance as a predictor of cognitive functioning. Further studies should investigate how diverse political and socioeconomic contexts influence the relation between SES and cognitive functioning. © 2016 The Authors. Scandinavian Journal of Psychology published by Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  4. Observer-Based Stabilization of Spacecraft Rendezvous with Variable Sampling and Sensor Nonlinearity

    Directory of Open Access Journals (Sweden)

    Zhuoshi Li

    2013-01-01

    Full Text Available This paper addresses the observer-based control problem of spacecraft rendezvous with nonuniform sampling period. The relative dynamic model is based on the classical Clohessy-Wiltshire equation, and sensor nonlinearity and sampling are considered together in a unified framework. The purpose of this paper is to perform an observer-based controller synthesis by using sampled and saturated output measurements, such that the resulting closed-loop system is exponentially stable. A time-dependent Lyapunov functional is developed which depends on time and the upper bound of the sampling period and also does not grow along the input update times. The controller design problem is solved in terms of the linear matrix inequality method, and the obtained results are less conservative than using the traditional Lyapunov functionals. Finally, a numerical simulation example is built to show the validity of the developed sampled-data control strategy.

  5. Correlation Functions in Open Quantum-Classical Systems

    OpenAIRE

    Hsieh, Chang-Yu; Kapral, Raymond

    2013-01-01

    Quantum time correlation functions are often the principal objects of interest in experimental investigations of the dynamics of quantum systems. For instance, transport properties, such as diffusion and reaction rate coefficients, can be obtained by integrating these functions. The evaluation of such correlation functions entails sampling from quantum equilibrium density operators and quantum time evolution of operators. For condensed phase and complex systems, where quantum dynamics is diff...

  6. Some physical and functional properties of finger millet (Eleusine coracana) obtained in sub-Saharan Africa.

    Science.gov (United States)

    Ramashia, S E; Gwata, E T; Meddows-Taylor, S; Anyasi, T A; Jideani, A I O

    2018-02-01

    The study determined the physical properties of finger millet (FM) (Eluesine coracana) grains and the functional properties of FM flour. Physical properties such as colour attributes, sample weight, bulk density, true density, porosity, surface area, sample volume, aspect ratio, sphericity, dimensional properties and moisture content of grain cultivars were determined. Water absorption capacity (WAC), bulk density (BD), dispersibility, viscosity and micro-structure of FM flours were also evaluated. Data collected were analyzed using SPSS statistical software version 23.0. Results showed that milky cream cultivar was significantly higher (pmillet, used as a control, was significantly different from FM flour on all dimensional properties. Moisture content of milky cream showed higher significant difference for both grains and flours as compared to brown and black grain/flours. Milky cream cultivar was significantly different in L*, b*, C*, H* values, WAC, BD and dispersibility for both FM grains and flours. Data showed that brown flour was significantly higher in viscosity than in milky and black flours. Microstructure results revealed that starch granules of raw FM flours had oval/spherical and smooth surface. The study is important for agricultural and food engineers, designers, scientists and processors in the design of equipment for FM grain processing. Results are likely to be useful in assessing the quality of grains used to fortify FM flour. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. High-throughput immunoturbidimetric assays for in-process determination of polyclonal antibody concentration and functionality in crude samples

    DEFF Research Database (Denmark)

    Bak, Hanne; Kyhse-Andersen, J.; Thomas, O.R.T.

    2007-01-01

    We present fast, simple immunoturbidimetric assays suitable for direct determination of antibody 'concentration' and 'functionality' in crude samples, such as in-process samples taken at various stages during antibody purification. Both assays display excellent linearity and analytical recovery. ...... antibodies, require only basic laboratory equipment, are robust, fast, cheap, easy to perform, and readily adapted to automation....

  8. Efficiency corrections in determining the (137)Cs inventory of environmental soil samples by using relative measurement method and GEANT4 simulations.

    Science.gov (United States)

    Li, Gang; Liang, Yongfei; Xu, Jiayun; Bai, Lixin

    2015-08-01

    The determination of (137)Cs inventory is widely used to estimate the soil erosion or deposition rate. The generally used method to determine the activity of volumetric samples is the relative measurement method, which employs a calibration standard sample with accurately known activity. This method has great advantages in accuracy and operation only when there is a small difference in elemental composition, sample density and geometry between measuring samples and the calibration standard. Otherwise it needs additional efficiency corrections in the calculating process. The Monte Carlo simulations can handle these correction problems easily with lower financial cost and higher accuracy. This work presents a detailed description to the simulation and calibration procedure for a conventionally used commercial P-type coaxial HPGe detector with cylindrical sample geometry. The effects of sample elemental composition, density and geometry were discussed in detail and calculated in terms of efficiency correction factors. The effect of sample placement was also analyzed, the results indicate that the radioactive nuclides and sample density are not absolutely uniform distributed along the axial direction. At last, a unified binary quadratic functional relationship of efficiency correction factors as a function of sample density and height was obtained by the least square fitting method. This function covers the sample density and height range of 0.8-1.8 g/cm(3) and 3.0-7.25 cm, respectively. The efficiency correction factors calculated by the fitted function are in good agreement with those obtained by the GEANT4 simulations with the determination coefficient value greater than 0.9999. The results obtained in this paper make the above-mentioned relative measurements more accurate and efficient in the routine radioactive analysis of environmental cylindrical soil samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Sex determination by tooth size in a sample of Greek population.

    Science.gov (United States)

    Mitsea, A G; Moraitis, K; Leon, G; Nicopoulou-Karayianni, K; Spiliopoulou, C

    2014-08-01

    Sex assessment from tooth measurements can be of major importance for forensic and bioarchaeological investigations, especially when only teeth or jaws are available. The purpose of this study is to assess the reliability and applicability of establishing sex identity in a sample of Greek population using the discriminant function proposed by Rösing et al. (1995). The study comprised of 172 dental casts derived from two private orthodontic clinics in Athens. The individuals were randomly selected and all had clear medical history. The mesiodistal crown diameters of all the teeth were measured apart from those of the 3rd molars. The values quoted for the sample to which the discriminant function was first applied were similar to those obtained for the Greek sample. The results of the preliminary statistical analysis did not support the use of the specific discriminant function for a reliable determination of sex by means of the mesiodistal diameter of the teeth. However, there was considerable variation between different populations and this might explain the reason for lack of discriminating power of the specific function in the Greek population. In order to investigate whether a better discriminant function could be obtained using the Greek data, separate discriminant function analysis was performed on the same teeth and a different equation emerged without, however, any real improvement in the classification process, with an overall correct classification of 72%. The results showed that there were a considerably higher percentage of females correctly classified than males. The results lead to the conclusion that the use of the mesiodistal diameter of teeth is not as a reliable method as one would have expected for determining sex of human remains from a forensic context. Therefore, this method could be used only in combination with other identification approaches. Copyright © 2014. Published by Elsevier GmbH.

  10. Assessing representativeness of sampling methods for reaching men who have sex with men: a direct comparison of results obtained from convenience and probability samples.

    Science.gov (United States)

    Schwarcz, Sandra; Spindler, Hilary; Scheer, Susan; Valleroy, Linda; Lansky, Amy

    2007-07-01

    Convenience samples are used to determine HIV-related behaviors among men who have sex with men (MSM) without measuring the extent to which the results are representative of the broader MSM population. We compared results from a cross-sectional survey of MSM recruited from gay bars between June and October 2001 to a random digit dial telephone survey conducted between June 2002 and January 2003. The men in the probability sample were older, better educated, and had higher incomes than men in the convenience sample, the convenience sample enrolled more employed men and men of color. Substance use around the time of sex was higher in the convenience sample but other sexual behaviors were similar. HIV testing was common among men in both samples. Periodic validation, through comparison of data collected by different sampling methods, may be useful when relying on survey data for program and policy development.

  11. Relational Intimacy Mediates Sexual Outcomes Associated With Impaired Sexual Function: Examination in a Clinical Sample.

    Science.gov (United States)

    Witherow, Marta Parkanyi; Chandraiah, Shambhavi; Seals, Samantha R; Sarver, Dustin E; Parisi, Kathryn E; Bugan, Antal

    2017-06-01

    Relational intimacy is hypothesized to underlie the association between female sexual functioning and various sexual outcomes, and married women and women with sexual dysfunction have been generally absent from prior studies investigating these associations, thus restricting generalizability. To investigate whether relational intimacy mediates sexual outcomes (sexual satisfaction, coital frequency, and sexual distress) in a sample of married women with and without impaired sexual functioning presenting in clinical settings. Using a cross-sectional design, 64 heterosexual married women with (n = 44) and without (n = 20) impaired sexual functioning completed a battery of validated measurements assessing relational intimacy, sexual dysfunction, sexual frequency, satisfaction, and distress. Intimacy measurements were combined using latent factor scores before analysis. Bias-corrected mediation models of the indirect effect were used to test mediation effects. Moderated mediation models examined whether indirect effects were influenced by age and marital duration. Patients completed the Female Sexual Function Index, the Couple's Satisfaction Index, the Sexual Satisfaction Scale for Women, the Inclusion of the Other in the Self Scale, and the Miller Social Intimacy Test. Mediation models showed that impaired sexual functioning is associated with all sexual outcomes directly and indirectly through relational intimacy. Results were predominantly independent of age and marital duration. Findings have important treatment implications for modifying interventions to focus on enhancing relational intimacy to improve the sexual functioning of women with impaired sexual functioning. The importance of the role relational intimacy plays in broad sexual outcomes of women with impaired sexual functioning is supported in clinically referred and married women. Latent factor scores to improve estimation of study constructs and the use of contemporary mediation analysis also are

  12. DNA Sampling Hook

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The DNA Sampling Hook is a significant improvement on a method of obtaining a tissue sample from a live fish in situ from an aquatic environment. A tissue sample...

  13. Minimum variance Monte Carlo importance sampling with parametric dependence

    International Nuclear Information System (INIS)

    Ragheb, M.M.H.; Halton, J.; Maynard, C.W.

    1981-01-01

    An approach for Monte Carlo Importance Sampling with parametric dependence is proposed. It depends upon obtaining by proper weighting over a single stage the overall functional dependence of the variance on the importance function parameter over a broad range of its values. Results corresponding to minimum variance are adapted and other results rejected. Numerical calculation for the estimation of intergrals are compared to Crude Monte Carlo. Results explain the occurrences of the effective biases (even though the theoretical bias is zero) and infinite variances which arise in calculations involving severe biasing and a moderate number of historis. Extension to particle transport applications is briefly discussed. The approach constitutes an extension of a theory on the application of Monte Carlo for the calculation of functional dependences introduced by Frolov and Chentsov to biasing, or importance sample calculations; and is a generalization which avoids nonconvergence to the optimal values in some cases of a multistage method for variance reduction introduced by Spanier. (orig.) [de

  14. Effects of coagulation temperature on measurements of complement function in serum samples from patients with systemic lupus erythematosus

    DEFF Research Database (Denmark)

    Baatrup, G; Sturfelt, G; Junker, A

    1992-01-01

    Blood samples from 15 patients with systemic lupus erythematosus (SLE) and 15 healthy blood donors were allowed to coagulate for one hour at room temperature, followed by one hour at 4 or 37 degrees C. The complement activity of the serum samples was assessed by three different functional assays...

  15. Influence of secular trends and sample size on reference equations for lung function tests.

    Science.gov (United States)

    Quanjer, P H; Stocks, J; Cole, T J; Hall, G L; Stanojevic, S

    2011-03-01

    The aim of our study was to determine the contribution of secular trends and sample size to lung function reference equations, and establish the number of local subjects required to validate published reference values. 30 spirometry datasets collected between 1978 and 2009 provided data on healthy, white subjects: 19,291 males and 23,741 females aged 2.5-95 yrs. The best fit for forced expiratory volume in 1 s (FEV(1)), forced vital capacity (FVC) and FEV(1)/FVC as functions of age, height and sex were derived from the entire dataset using GAMLSS. Mean z-scores were calculated for individual datasets to determine inter-centre differences. This was repeated by subdividing one large dataset (3,683 males and 4,759 females) into 36 smaller subsets (comprising 18-227 individuals) to preclude differences due to population/technique. No secular trends were observed and differences between datasets comprising >1,000 subjects were small (maximum difference in FEV(1) and FVC from overall mean: 0.30- -0.22 z-scores). Subdividing one large dataset into smaller subsets reproduced the above sample size-related differences and revealed that at least 150 males and 150 females would be necessary to validate reference values to avoid spurious differences due to sampling error. Use of local controls to validate reference equations will rarely be practical due to the numbers required. Reference equations derived from large or collated datasets are recommended.

  16. Sample size requirements for studies of treatment effects on beta-cell function in newly diagnosed type 1 diabetes.

    Science.gov (United States)

    Lachin, John M; McGee, Paula L; Greenbaum, Carla J; Palmer, Jerry; Pescovitz, Mark D; Gottlieb, Peter; Skyler, Jay

    2011-01-01

    Preservation of β-cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet), repeated 2-hour Mixed Meal Tolerance Tests (MMTT) were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC) of the C-peptide values. The natural log(x), log(x+1) and square-root (√x) transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8-12 years of age, adolescents (13-17 years) and adults (18+ years). The sample size needed to detect a given relative (percentage) difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13-17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(x+1) and √x transformed values in terms of the original units of measurement (pmol/ml). Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab) versus masked placebo. These results provide the information needed to accurately

  17. Sample size requirements for studies of treatment effects on beta-cell function in newly diagnosed type 1 diabetes.

    Directory of Open Access Journals (Sweden)

    John M Lachin

    Full Text Available Preservation of β-cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet, repeated 2-hour Mixed Meal Tolerance Tests (MMTT were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC of the C-peptide values. The natural log(x, log(x+1 and square-root (√x transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8-12 years of age, adolescents (13-17 years and adults (18+ years. The sample size needed to detect a given relative (percentage difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13-17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(x+1 and √x transformed values in terms of the original units of measurement (pmol/ml. Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab versus masked placebo. These results provide the information needed to

  18. No correlation between ultrasound placental grading at 31-34 weeks of gestation and a surrogate estimate of organ function at term obtained by stereological analysis.

    Science.gov (United States)

    Yin, T T; Loughna, P; Ong, S S; Padfield, J; Mayhew, T M

    2009-08-01

    We test the experimental hypothesis that early changes in the ultrasound appearance of the placenta reflect poor or reduced placental function. The sonographic (Grannum) grade of placental maturity was compared to placental function as expressed by the morphometric oxygen diffusive conductance of the villous membrane. Ultrasonography was used to assess the Grannum grade of 32 placentas at 31-34 weeks of gestation. Indications for the scans included a history of previous fetal abnormalities, previous fetal growth problems or suspicion of IUGR. Placentas were classified from grade 0 (most immature) to grade III (most mature). We did not exclude smokers or complicated pregnancies as we aimed to correlate the early appearance of mature placentas with placental function. After delivery, microscopical fields on formalin-fixed, trichrome-stained histological sections of each placenta were obtained by multistage systematic uniform random sampling. Using design-based stereological methods, the exchange surface areas of peripheral (terminal and intermediate) villi and their fetal capillaries and the arithmetic and harmonic mean thicknesses of the villous membrane (maternal surface of villous trophoblast to adluminal surface of vascular endothelium) were estimated. An index of the variability in thickness of this membrane, and an estimate of its oxygen diffusive conductance, were derived secondarily as were estimates of the mean diameters and total lengths of villi and fetal capillaries. Group comparisons were drawn using analysis of variance. We found no significant differences in placental volume or composition or in the dimensions or diffusive conductances of the villous membrane. Subsequent exclusion of smokers did not alter these main findings. Grannum grades at 31-34 weeks of gestation appear not to provide reliable predictors of the functional capacity of the term placenta as expressed by the surrogate measure, morphometric diffusive conductance.

  19. Dynamics of entanglement between two atomic samples with spontaneous scattering

    International Nuclear Information System (INIS)

    Di Lisi, Antonio; De Siena, Silvio; Illuminati, Fabrizio

    2004-01-01

    We investigate the effects of spontaneous scattering on the evolution of entanglement of two atomic samples, probed by phase-shift measurements on optical beams interacting with both samples. We develop a formalism of conditional quantum evolutions and present a wave function analysis implemented in numerical simulations of the state vector dynamics. This method allows us to track the evolution of entanglement and to compare it with the predictions obtained when spontaneous scattering is neglected. We provide numerical evidence that the interferometric scheme to entangle atomic samples is only marginally affected by the presence of spontaneous scattering and should thus be robust even in more realistic situations

  20. The effect of ageing on YBa2Cu3O7-x obtained by the photoacoustic method

    Directory of Open Access Journals (Sweden)

    Nikolić Pantelija M.

    2003-01-01

    Full Text Available Thermal diffusivity and electric transport properties of fourteen years old superconducting YBa2Cu3O7-x pellets were obtained using the photoacoustic transmission technique and then compared with freshly made superconducting samples. The theoretical model for photoacoustic (PA detection configuration is given. The measured amplitude and phase PA signals, as a function of the modulation frequency, were numerically analyzed. The thermal diffusivity, the coefficient of the carrier diffusion, optical absorption coefficient and the excess carrier lifetime were calculated. The thermal diffusivity of freshly produced samples decreased, after ageing, from about 1.3·10-6 to about 6.1·10-7 m2/s.

  1. An Optimal Estimation Method to Obtain Surface Layer Turbulent Fluxes from Profile Measurements

    Science.gov (United States)

    Kang, D.

    2015-12-01

    In the absence of direct turbulence measurements, the turbulence characteristics of the atmospheric surface layer are often derived from measurements of the surface layer mean properties based on Monin-Obukhov Similarity Theory (MOST). This approach requires two levels of the ensemble mean wind, temperature, and water vapor, from which the fluxes of momentum, sensible heat, and water vapor can be obtained. When only one measurement level is available, the roughness heights and the assumed properties of the corresponding variables at the respective roughness heights are used. In practice, the temporal mean with large number of samples are used in place of the ensemble mean. However, in many situations the samples of data are taken from multiple levels. It is thus desirable to derive the boundary layer flux properties using all measurements. In this study, we used an optimal estimation approach to derive surface layer properties based on all available measurements. This approach assumes that the samples are taken from a population whose ensemble mean profile follows the MOST. An optimized estimate is obtained when the results yield a minimum cost function defined as a weighted summation of all error variance at each sample altitude. The weights are based one sample data variance and the altitude of the measurements. This method was applied to measurements in the marine atmospheric surface layer from a small boat using radiosonde on a tethered balloon where temperature and relative humidity profiles in the lowest 50 m were made repeatedly in about 30 minutes. We will present the resultant fluxes and the derived MOST mean profiles using different sets of measurements. The advantage of this method over the 'traditional' methods will be illustrated. Some limitations of this optimization method will also be discussed. Its application to quantify the effects of marine surface layer environment on radar and communication signal propagation will be shown as well.

  2. Typology of perceived family functioning in an American sample of patients with advanced cancer.

    Science.gov (United States)

    Schuler, Tammy A; Zaider, Talia I; Li, Yuelin; Hichenberg, Shira; Masterson, Melissa; Kissane, David W

    2014-08-01

    Poor family functioning affects psychosocial adjustment and the occurrence of morbidity following bereavement in the context of a family's coping with advanced cancer. Family functioning typologies assist with targeted family-centered assessment and intervention to offset these complications in the palliative care setting. Our objective was to identify the number and nature of potential types in an American palliative care patient sample. Data from patients with advanced cancer (N = 1809) screened for eligibility for a larger randomized clinical trial were used. Cluster analyses determined whether patients could be classified into clinically meaningful and coherent groups, based on similarities in their perceptions of family functioning across the cohesiveness, expressiveness, and conflict resolution subscales of the Family Relations Index. Patients' reports of perceived family functioning yielded a model containing five meaningful family types. Cohesiveness, expressiveness, and conflict resolution appear to be useful dimensions by which to classify patient perceptions of family functioning. "At risk" American families may include those we have called hostile, low-communicating, and less-involved. Such families may benefit from adjuvant family-centered psychosocial services, such as family therapy. Copyright © 2014 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  3. On the assessment of extremely low breakdown probabilities by an inverse sampling procedure [gaseous insulation

    DEFF Research Database (Denmark)

    Thyregod, Poul; Vibholm, Svend

    1991-01-01

    the flashover probability function and the corresponding distribution of first breakdown voltages under the inverse sampling procedure, and show how this relation may be utilized to assess the single-shot flashover probability corresponding to the observed average first breakdown voltage. Since the procedure......First breakdown voltages obtained under the inverse sampling procedure assuming a double exponential flashover probability function are discussed. An inverse sampling procedure commences the voltage application at a very low level, followed by applications at stepwise increased levels until...... is based on voltage applications in the neighbourhood of the quantile under investigation, the procedure is found to be insensitive to the underlying distributional assumptions...

  4. Traumatic stress and psychological functioning in a South African adolescent community sample

    Directory of Open Access Journals (Sweden)

    Karl D. Swain

    2017-03-01

    Full Text Available Background: Traumatic stress may arise from various incidents often leading to posttraumatic stress disorder (PTSD. The lifetime prevalence of PTSD is estimated at 1% – 2% in Western Europe, 6% – 9% in North America and at just over 10% in countries exposed to long-term violence. In South Africa, the lifetime prevalence for PTSD in the general population is estimated at 2.3%. Aim: To examine the prevalence of posttraumatic stress symptomatology and related psychological functioning in a community sample of adolescents. Setting: Low-socioeconomic communities in KwaZulu-Natal. Methods: Home interviews with adolescents and their maternal caregivers were used to collect the data using standardised instruments. Adolescents completed the Trauma Symptom Checklist for Children; Children’s Depression Inventory; Children’s Somatization Inventory; and Revised Children’s Manifest Anxiety Scale. The Child Behaviour Checklist was completed by the caregivers. The sample comprised Grade 7 (n = 256 and Grade 10 (n = 68 learners. Sixty-five percent of the sample was female, and ages ranged from 9 to 18 (M = 13.11, s.d. = 1.54. Results: Almost 6% of the sample endorsed PTSD and an additional 4% of the participants had clinically significant traumatic stress symptomatology. There was a significant, large, positive correlation between posttraumatic stress and anxiety, and medium positive correlations between posttraumatic stress and depression and somatic symptoms. Conclusion: Posttraumatic stress symptomatology can be debilitating, often co-occurring with symptoms of depression, anxiety and somatic complications. This may lead to long-term academic, social and emotional consequences in this vulnerable group.

  5. The distribution function of crystalline orientation's usefulness in crystallographic texture analysis

    International Nuclear Information System (INIS)

    Hermida, J.D.; Pochettino, A.A.

    1982-01-01

    The theoretical fundaments of the Distribution Function of Crystalline Orientations (DFCO) are described and this method is compared with the usual description of the crystallographic texture by direct pole figures. Such function is applied to the study of a Zry-4 sample obtained from a tube belonging to a CANDU type fuel element. The DFCO is obtained from the pole figures (0002), (101-bar0) and (101-bar1). The results show the existence of six fundamental components of texture, which are enunciated below, in decreasing order of importance: (2-bar115) ; (3-bar128) ; (1-bar013) ; (2-bar114) ; (0001) ; (0001) . A much more complete view of the crystals' orientation state of such sample can be obtained by analyzing the weight and the distribution of the different components. (M.E.L.) [es

  6. Cannabis use and neurocognitive functioning in a non-clinical sample of users.

    Science.gov (United States)

    Thames, April D; Arbid, Natalie; Sayegh, Philip

    2014-05-01

    With the recent debates over marijuana legalization and increases in use, it is critical to examine its role in cognition. While many studies generally support the adverse acute effects of cannabis on neurocognition, the non-acute effects remain less clear. The current study used a cross-sectional design to examine relationships between recent and past cannabis use on neurocognitive functioning in a non-clinical adult sample. One hundred and fifty-eight participants were recruited through fliers distributed around local college campuses and the community. All participants completed the Brief Drug Use History Form, the Structured Clinical Interview for DSM-IV Disorders, and neurocognitive assessment, and underwent urine toxicology screening. Participants consisted of recent users (n=68), past users (n=41), and non-users (n=49). Recent users demonstrated significantly (pcannabis use in the last 4 weeks was negatively associated with global neurocognitive performance and all individual cognitive domains. Similarly, amount of daily cannabis use was negatively associated with global neurocognitive performance and individual cognitive domains. Our results support the widespread adverse effects of cannabis use on neurocognitive functioning. Although some of these adverse effects appear to attenuate with abstinence, past users' neurocognitive functioning was consistently lower than non-users. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Rotary Mode Core Sample System availability improvement

    International Nuclear Information System (INIS)

    Jenkins, W.W.; Bennett, K.L.; Potter, J.D.; Cross, B.T.; Burkes, J.M.; Rogers, A.C.

    1995-01-01

    The Rotary Mode Core Sample System (RMCSS) is used to obtain stratified samples of the waste deposits in single-shell and double-shell waste tanks at the Hanford Site. The samples are used to characterize the waste in support of ongoing and future waste remediation efforts. Four sampling trucks have been developed to obtain these samples. Truck I was the first in operation and is currently being used to obtain samples where the push mode is appropriate (i.e., no rotation of drill). Truck 2 is similar to truck 1, except for added safety features, and is in operation to obtain samples using either a push mode or rotary drill mode. Trucks 3 and 4 are now being fabricated to be essentially identical to truck 2

  8. Functional and antioxidant properties of protein hydrolysates obtained from white shrimp (Litopenaeus vannamei).

    Science.gov (United States)

    Latorres, J M; Rios, D G; Saggiomo, G; Wasielesky, W; Prentice-Hernandez, C

    2018-02-01

    Protein hydrolysates from white shrimp ( Litopenaeus vannamei ) with different degrees of hydrolysis (DH-10 and 20%) were prepared using the enzymes Alcalase 2.4 L and Protamex. The hydrolysates were evaluated for amino acid composition, solubility, foaming properties, emulsifying and antioxidant activity. All the hydrolysates showed high concentrations of Glutamic Acid, Aspartic acid, Arginine, Glycine, Lysine, Proline. It was found that the increase in the production of negatively charged amino acids was related to increase in DH. The hydrophobic amino acids were higher for hydrolysates obtained with Alcalase (10% DH) and Protamex (20% DH). The results indicated that higher degree of hydrolysis showed positive relation with the protein solubility of the hydrolysates, while negatively influenced foam and emulsification properties. The antioxidant properties presented by the white shrimp protein hydrolysates were influenced by the composition and peptides size. Hydrolysates with higher peptide chain showed the highest antioxidant power for the 2,2-Diphenyl-1-picrylhydrazyl radical scavenging and reducing power, while hydrolysates with lower peptide chain showed higher antioxidant power for 2,2'-azinobis (3-ethylbenzothiazoline sulfonic acid) radical scavenging. All hydrolysates showed dose-dependent antioxidant activities. Therefore, the results of the present study suggest that white shrimp is a potential source of protein hydrolysates as bioactive ingredients for the use in the formulation of functional foods as well as natural antioxidants in lipid food systems.

  9. Sampling procedure, receipt and conservation of water samples to determine environmental radioactivity

    International Nuclear Information System (INIS)

    Herranz, M.; Navarro, E.; Payeras, J.

    2009-01-01

    The present document informs about essential goals, processes and contents that the subgroups Sampling and Samples Preparation and Conservation believe they should be part of the procedure to obtain a correct sampling, receipt, conservation and preparation of samples of continental, marine and waste water before qualifying its radioactive content.

  10. Pumping time required to obtain tube well water samples with aquifer characteristic radon concentrations

    International Nuclear Information System (INIS)

    Ricardo, Carla Pereira; Oliveira, Arno Heeren de

    2011-01-01

    Radon is an inert noble gas, which comes from the natural radioactive decay of uranium and thorium in soil, rock and water. Radon isotopes emanated from radium-bearing grains of a rock or soil are released into the pore space. Radon that reaches the pore space is partitioned between the gaseous and aqueous phases. Thus, the groundwater presents a radon signature from the rock that is characteristic of the aquifer. The characteristic radon concentration of an aquifer, which is mainly related to the emanation, is also influenced by the degree of subsurface degassing, especially in the vicinity of a tube well, where the radon concentration is strongly reduced. Looking for the required pumping time to take a tube well water sample that presents the characteristic radon concentration of the aquifer, an experiment was conducted in an 80 m deep tube well. In this experiment, after twenty-four hours without extraction, water samples were collected periodically, about ten minutes intervals, during two hours of pumping time. The radon concentrations of the samples were determined by using the RAD7 Electronic Radon Detector from Durridge Company, a solid state alpha spectrometric detector. It was realized that the necessary time to reach the maximum radon concentration, that means the characteristic radon concentration of the aquifer, is about sixty minutes. (author)

  11. Some Risk Factors of Chronic Functional Constipation Identified in a Pediatric Population Sample from Romania

    Directory of Open Access Journals (Sweden)

    Claudia Olaru

    2016-01-01

    Full Text Available We conducted an observational study over a 1-year period, including 234 children aged 4–18 years and their caregivers and a matching control group. 60.73% of the children from the study group were males. Average age for the onset of constipation was 26.39 months. The frequency of defecation was 1/4.59 days (1/1.13 days in the control group. 38.49% of the patients in the sample group had a positive family history of functional constipation. The majority of children with functional constipation come from single-parent families, are raised by relatives, or come from orphanages. Constipated subjects had their last meal of the day at later hours and consumed fast foods more frequently than the children in the control sample. We found a statistically significant difference between groups regarding obesity/overweight and constipation (χ2=104.94,  df=2,  p<0.001 and regarding physical activity and constipation (χ2=18.419;  df=3;  p<0.001. There was a positive correlation between the number of hours spent watching television/using the computer and the occurrence of the disease (F = 92.162, p<0.001, and 95% Cl. Children from broken families, with positive family history, defective dietary habits, obesity and sedentary behavior, are at higher risk to develop chronic functional constipation.

  12. Organoclays obtaining starting up of clays sodium

    International Nuclear Information System (INIS)

    Silva, M.M. da; Mota, M.F.; Oliveira, G.C. de; Rodrigues, M.G.F.

    2012-01-01

    Clays have several applications in many areas of fields of technology, however, modification of these materials using organic compounds can be performed to obtain further hydrophobic materials, for applications in the adsorption of organic pollutants. This study aimed to analyze the effects of modifying two clays using sodium quaternary ammonium surfactants through ion exchange reaction process, in obtaining organoclays. The samples with sodium and organoclays were characterized by the techniques of X-ray diffraction (XRD), Infrared Spectroscopy in the region (IV), Gravimetric and Differential Thermal Analysis (DTA / TG) and organic adsorption tests. The results show that the process of obtaining organoclay is efficient, and materials have the potential for future applications in removing organic contaminants. (author)

  13. Light sensitive polymer obtained by dispersion of azo-functionalized POSS nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Miniewicz, A., E-mail: andrzej.miniewicz@pwr.edu.pl [Advanced Materials Engineering and Modelling, Faculty of Chemistry, Wroclaw University of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw (Poland); Tomkowicz, M.; Karpinski, P.; Sznitko, L. [Advanced Materials Engineering and Modelling, Faculty of Chemistry, Wroclaw University of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw (Poland); Mossety-Leszczak, B. [Faculty of Chemistry, Rzeszow University of Technology, Al. Powstancow Warszawy 12, 35-959 Rzeszow (Poland); Dutkiewicz, M. [Faculty of Chemistry, Adam Mickiewicz University of Poznan, Umultowska 89 B, 61-614 Poznan (Poland)

    2015-07-29

    Highlights: • Nanocomposite material PMMA containing azo-functionalized POSS has been prepared. • Surface topographies of prepared films are porous and dependent on azo-POSS content. • Photo-induced optical anisotropies both static and dynamic have been characterized. - Abstract: Hybrid inorganic–organic nanoparticles based on cubic siloxane cage (RSiO{sub 3/2}){sub 8}, known as polyhedral oligosilsesquioxane (POSS), have been functionalized by eight groups of azo-benzene mesogens and dispersed in poly(methyl methacrylate) PMMA matrix. Presence of azo-benzene units adds an important light-driven functionality to the system due to their photoisomerization resulting in refractive index and/or absorption changes of the whole system. The polymer films containing various concentrations of azo-POSS nanoparticles show remarkable changes of surface morphology being either transparent (at low POSS concentration) or highly scattering (at high POSS concentration) for visible light. Surface structures were examined by optical microscopy as well as by atomic force microscopy (AFM). Results of photoinduced alignment are discussed in the framework of light-induced modification of the aliphatic chains containing azo-benzene photoisomerizing moieties and self-organization process.

  14. Light sensitive polymer obtained by dispersion of azo-functionalized POSS nanoparticles

    International Nuclear Information System (INIS)

    Miniewicz, A.; Tomkowicz, M.; Karpinski, P.; Sznitko, L.; Mossety-Leszczak, B.; Dutkiewicz, M.

    2015-01-01

    Highlights: • Nanocomposite material PMMA containing azo-functionalized POSS has been prepared. • Surface topographies of prepared films are porous and dependent on azo-POSS content. • Photo-induced optical anisotropies both static and dynamic have been characterized. - Abstract: Hybrid inorganic–organic nanoparticles based on cubic siloxane cage (RSiO 3/2 ) 8 , known as polyhedral oligosilsesquioxane (POSS), have been functionalized by eight groups of azo-benzene mesogens and dispersed in poly(methyl methacrylate) PMMA matrix. Presence of azo-benzene units adds an important light-driven functionality to the system due to their photoisomerization resulting in refractive index and/or absorption changes of the whole system. The polymer films containing various concentrations of azo-POSS nanoparticles show remarkable changes of surface morphology being either transparent (at low POSS concentration) or highly scattering (at high POSS concentration) for visible light. Surface structures were examined by optical microscopy as well as by atomic force microscopy (AFM). Results of photoinduced alignment are discussed in the framework of light-induced modification of the aliphatic chains containing azo-benzene photoisomerizing moieties and self-organization process

  15. Mediators of the relationship between life events and memory functioning in a community sample of adults

    NARCIS (Netherlands)

    Korten, N.C.M.; Sliwinski, M.J.; Comijs, H.C.; Smyth, J.M.

    2014-01-01

    The present study examines the association of frequency and severity of life events with memory functioning in a community sample of adults. We tested the hypothesis that stress-related cognitive interference mediated the effects of recent life events on cognition, in addition to examining the

  16. COMPARISON OF GINGER (Zingiber officiale Roscoe OLEORESIN OBTAINED WITH ETHANOL AND ISOPROPANOL WITH THAT OBTAINED WITH PRESSURIZED CO2

    Directory of Open Access Journals (Sweden)

    Lia P. NOBREGA

    1997-12-01

    Full Text Available Ginger (Zingiber officinale Roscoe belongs to the Zingiberacea family. It is a spice of great commercial importance. In this work ginger oleoresin was obtained with ethanol, isopropanol and liquid carbon dioxide. The chemical compositions of the extract were compared with each other. All oleoresin samples had monoterpenes and sesquiterpenes. Carboxylic acids were found in organic solvent extracts for an extraction time of 2 hours. The component responsible the for pungent characteristic of the oleoresin, gingerois, were detected in samples obtained with organic solvent for extraction times of 6 hours and in samples obtained with CO2 liquid for extraction times of 2 hours.O gengibre (Zingiber officinale Roscoe pertence à família Zingiberacea. É uma especiaria de grande importância comercial. Neste trabalho realizou-se extrações da oleoresina de gengibre com etanol, isopropanol e dióxido de carbono líquido e comparou-se a composição química de cada um dos extratos. A oleoresina obtida tem componentes das classes dos monoterpenos e sesquiterpenos em todas as amostras. Ácidos carboxílicos foram encontrados nos extratos obtidos com solvente orgânico, quando o tempo de extração foi de 2 horas. Os componentes que dão a característica pungente à oleoresina, os gingerois, foram detectados nas amostras obtidas com solvente orgânico, quando o tempo de extração foi de 6 horas e, nas amostras obtidas com CO2 líquido, com 2 horas de extração.

  17. Nonparametric estimation of the stationary M/G/1 workload distribution function

    DEFF Research Database (Denmark)

    Hansen, Martin Bøgsted

    2005-01-01

    In this paper it is demonstrated how a nonparametric estimator of the stationary workload distribution function of the M/G/1-queue can be obtained by systematic sampling the workload process. Weak convergence results and bootstrap methods for empirical distribution functions for stationary associ...

  18. Effects of assisted training with neurofeedback on EEG measures, executive function and mood in a healthy sample

    Directory of Open Access Journals (Sweden)

    Milena Vasquez

    2015-01-01

    Full Text Available The training in neurofeedback (NF consists of teaching individuals to modify, adjust and enhance their brain activity pattern. The aim of our research was to evaluate the effect of training on cognitive processes, specifically executive function, and mood in a non-clinical sample. A sample of 30 female college students were assigned to three groups: RH: right hemisphere (n = 10, LH: left hemisphere (n = 10 and control (n = 10. The dominance pattern of beta and the inhibition of the theta pattern were trained in a single session. Measures of executive function (Iowa Gambling Test and questionnaires of mood were taken pre and post training. We found that NF training produced significant positive changes in executive performance in the RH group. In the EEG a tendency to improve beta rhythm after the training emerged too. Additionally, significant correlations were found between executive performance and negative mood in relation to theta frequency band. We conclude that the protocol seems effective to enhance some aspects of executive function as well as to decrease theta power improves the negative mood.

  19. Efficiently sampling conformations and pathways using the concurrent adaptive sampling (CAS) algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Surl-Hee; Grate, Jay W.; Darve, Eric F.

    2017-08-21

    Molecular dynamics (MD) simulations are useful in obtaining thermodynamic and kinetic properties of bio-molecules but are limited by the timescale barrier, i.e., we may be unable to efficiently obtain properties because we need to run microseconds or longer simulations using femtoseconds time steps. While there are several existing methods to overcome this timescale barrier and efficiently sample thermodynamic and/or kinetic properties, problems remain in regard to being able to sample un- known systems, deal with high-dimensional space of collective variables, and focus the computational effort on slow timescales. Hence, a new sampling method, called the “Concurrent Adaptive Sampling (CAS) algorithm,” has been developed to tackle these three issues and efficiently obtain conformations and pathways. The method is not constrained to use only one or two collective variables, unlike most reaction coordinate-dependent methods. Instead, it can use a large number of collective vari- ables and uses macrostates (a partition of the collective variable space) to enhance the sampling. The exploration is done by running a large number of short simula- tions, and a clustering technique is used to accelerate the sampling. In this paper, we introduce the new methodology and show results from two-dimensional models and bio-molecules, such as penta-alanine and triazine polymer

  20. Real-Time PCR in faecal samples of Triatoma infestans obtained by xenodiagnosis: proposal for an exogenous internal control.

    Science.gov (United States)

    Bravo, Nicolás; Muñoz, Catalina; Nazal, Nicolás; Saavedra, Miguel; Martínez, Gabriela; Araya, Eduardo; Apt, Werner; Zulantay, Inés

    2012-03-26

    The polymerase chain reaction (PCR) has proved to be a sensitive technique to detect Trypanosoma cruzi in the chronic phase of Chagas disease, which is characterized by low and fluctuating parasitemia. Another technique proposed for parasitological diagnosis in this phase of infection combines a microscopic search for motile trypomastigote forms in faecal samples (FS) obtained by xenodiagnosis (XD) with conventional PCR (XD-PCR). In this study we evaluate the use of human blood DNA as an exogenous internal control (EIC) for real time PCR (qPCR) combined with XD (XD-qPCR) using chromosome 12 (X12) detection. None of the FS-XD evaluated by qPCR amplified for X12. Nevertheless, all the EIC-FS-XD mixtures amplified for X12. We determined that X12 is useful as an EIC for XD-qPCR because we showed that the FS-XD does not contain human DNA after 30 or more days of XD incubation. This information is relevant for research on T. cruzi by XD-qPCR since it allows ruling out inhibition and false negative results due to DNA loss during the process of extraction and purification.

  1. Influence of spark plasma sintering conditions on the sintering and functional properties of an ultra-fine grained 316L stainless steel obtained from ball-milled powder

    Energy Technology Data Exchange (ETDEWEB)

    Keller, C., E-mail: clement.keller@insa-rouen.fr [Groupe de Physique des Matériaux, CNRS-UMR 6634, Université de Rouen, INSA de Rouen, Avenue de l' Université, 76800 Saint-Etienne du Rouvray (France); Tabalaiev, K.; Marnier, G. [Groupe de Physique des Matériaux, CNRS-UMR 6634, Université de Rouen, INSA de Rouen, Avenue de l' Université, 76800 Saint-Etienne du Rouvray (France); Noudem, J. [Laboratoire de Cristallographie des Matériaux, CNRS-UMR 6508, Université de Caen, ENSICAEN, 7 bd du Maréchal Juin, 14050 Caen (France); Sauvage, X. [Groupe de Physique des Matériaux, CNRS-UMR 6634, Université de Rouen, INSA de Rouen, Avenue de l' Université, 76800 Saint-Etienne du Rouvray (France); Hug, E. [Laboratoire de Cristallographie des Matériaux, CNRS-UMR 6508, Université de Caen, ENSICAEN, 7 bd du Maréchal Juin, 14050 Caen (France)

    2016-05-17

    In this work, 316L samples with submicrometric grain size were sintered by spark plasma sintering. To this aim, 316L powder was first ball-milled with different conditions to obtain nanostructured powder. The process control agent quantity and milling time were varied to check their influence on the crystallite size of milled powder. Samples were then sintered by spark plasma sintering using different sets of sintering parameters (temperature, dwell time and pressure). For each sample, grain size and density were systematically measured in order to investigate the influence of the sintering process on these two key microstructure parameters. Results show that suitable ball-milling and subsequent sintering can be employed to obtain austenitic stainless steel samples with grain sizes in the nanometer range with porosity lower than 3%. However, ball-milling and subsequent sintering enhance chromium carbides formation at the sample surface in addition to intragranular and intergranular oxides in the sample as revealed by X-ray diffraction and transmission electron microscopy. It has been shown that using Boron nitride together with graphite foils to protect the mold from powder welding prevent such carbide formation. For mechanical properties, results show that the grain size refinement strongly increases the hardness of the samples without deviation from Hall-Petch relationship despite the oxides formation. For corrosion resistance, grain sizes lower than a few micrometers involve a strong decrease in the pitting potential and a strong increase in passivation current. As a consequence, spark plasma sintering can be considered as a promising tool for ultra-fine grained austenitic stainless steel.

  2. Varying Associations Between Body Mass Index and Physical and Cognitive Function in Three Samples of Older Adults Living in Different Settings.

    Science.gov (United States)

    Kiesswetter, Eva; Schrader, Eva; Diekmann, Rebecca; Sieber, Cornel Christian; Volkert, Dorothee

    2015-10-01

    The study investigates variations in the associations between body mass index (BMI) and (a) physical and (b) cognitive function across three samples of older adults living in different settings, and moreover determines if the association between BMI and physical function is confounded by cognitive abilities. One hundred ninety-five patients of a geriatric day hospital, 322 persons receiving home care (HC), and 183 nursing home (NH) residents were examined regarding BMI, cognitive (Mini-Mental State Examination), and physical function (Barthel Index for activities of daily living). Differences in Mini-Mental State Examination and activities of daily living scores between BMI groups (Examination impairments increased from the geriatric day hospital over the HC to the NH sample, whereas prevalence rates of obesity and severe obesity (35%, 33%, 25%) decreased. In geriatric day hospital patients cognitive and physical function did not differ between BMI groups. In the HC and NH samples, cognitive abilities were highest in obese and severely obese subjects. Unadjusted mean activities of daily living scores differed between BMI groups in HC receivers (51.6±32.2, 61.8±26.1, 67.5±28.3, 72.0±23.4, 66.2±24.2, p = .002) and NH residents (35.6±28.6, 48.1±25.7, 39.9±28.7, 50.8±24.0, 57.1±28.2, p = .029). In both samples significance was lost after adjustment indicating cognitive function as dominant confounder. In older adults the associations between BMI and physical and cognitive function were dependent on the health and care status corresponding to the setting. In the HC and the NH samples, cognitive status, as measured by the Mini-Mental State Examination, emerged as an important confounder within the association between BMI and physical function. © The Author 2015. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Deep versus periventricular white matter lesions and cognitive function in a community sample of middle-aged participants.

    Science.gov (United States)

    Soriano-Raya, Juan José; Miralbell, Júlia; López-Cancio, Elena; Bargalló, Núria; Arenillas, Juan Francisco; Barrios, Maite; Cáceres, Cynthia; Toran, Pere; Alzamora, Maite; Dávalos, Antoni; Mataró, Maria

    2012-09-01

    The association of cerebral white matter lesions (WMLs) with cognitive status is not well understood in middle-aged individuals. Our aim was to determine the specific contribution of periventricular hyperintensities (PVHs) and deep white matter hyperintensities (DWMHs) to cognitive function in a community sample of asymptomatic participants aged 50 to 65 years. One hundred stroke- and dementia-free adults completed a comprehensive neuropsychological battery and brain MRI protocol. Participants were classified according to PVH and DWMH scores (Fazekas scale). We dichotomized our sample into low grade WMLs (participants without or with mild lesions) and high grade WMLs (participants with moderate or severe lesions). Analyses were performed separately in PVH and DWMH groups. High grade DWMHs were associated with significantly lower scores in executive functioning (-0.45 standard deviations [SD]), attention (-0.42 SD), verbal fluency (-0.68 SD), visual memory (-0.52 SD), visuospatial skills (-0.79 SD), and psychomotor speed (-0.46 SD). Further analyses revealed that high grade DWMHs were also associated with a three- to fourfold increased risk of impaired scores (i.e.,<1.5 SD) in executive functioning, verbal fluency, visuospatial skills, and psychomotor speed. Our findings suggest that only DWMHs, not PVHs, are related to diminished cognitive function in middle-aged individuals. (JINS, 2012, 18, 1-12).

  4. New complete sample of identified radio sources. Part 2. Statistical study

    International Nuclear Information System (INIS)

    Soltan, A.

    1978-01-01

    Complete sample of radio sources with known redshifts selected in Paper I is studied. Source counts in the sample and the luminosity - volume test show that both quasars and galaxies are subject to the evolution. Luminosity functions for different ranges of redshifts are obtained. Due to many uncertainties only simplified models of the evolution are tested. Exponential decline of the liminosity with time of all the bright sources is in a good agreement both with the luminosity- volume test and N(S) realtion in the entire range of observed flux densities. It is shown that sources in the sample are randomly distributed in scales greater than about 17 Mpc. (author)

  5. Correlation Functions in Open Quantum-Classical Systems

    Directory of Open Access Journals (Sweden)

    Chang-Yu Hsieh

    2013-12-01

    Full Text Available Quantum time correlation functions are often the principal objects of interest in experimental investigations of the dynamics of quantum systems. For instance, transport properties, such as diffusion and reaction rate coefficients, can be obtained by integrating these functions. The evaluation of such correlation functions entails sampling from quantum equilibrium density operators and quantum time evolution of operators. For condensed phase and complex systems, where quantum dynamics is difficult to carry out, approximations must often be made to compute these functions. We present a general scheme for the computation of correlation functions, which preserves the full quantum equilibrium structure of the system and approximates the time evolution with quantum-classical Liouville dynamics. Several aspects of the scheme are discussed, including a practical and general approach to sample the quantum equilibrium density, the properties of the quantum-classical Liouville equation in the context of correlation function computations, simulation schemes for the approximate dynamics and their interpretation and connections to other approximate quantum dynamical methods.

  6. Development and optimization of a novel sample preparation method cored on functionalized nanofibers mat-solid-phase extraction for the simultaneous efficient extraction of illegal anionic and cationic dyes in foods.

    Science.gov (United States)

    Qi, Feifei; Jian, Ningge; Qian, Liangliang; Cao, Weixin; Xu, Qian; Li, Jian

    2017-09-01

    A simple and efficient three-step sample preparation method was developed and optimized for the simultaneous analysis of illegal anionic and cationic dyes (acid orange 7, metanil yellow, auramine-O, and chrysoidine) in food samples. A novel solid-phase extraction (SPE) procedure based on nanofibers mat (NFsM) was proposed after solvent extraction and freeze-salting out purification. The preferred SPE sorbent was selected from five functionalized NFsMs by orthogonal experimental design, and the optimization of SPE parameters was achieved through response surface methodology (RSM) based on the Box-Behnken design (BBD). Under the optimal conditions, the target analytes could be completely adsorbed by polypyrrole-functionalized polyacrylonitrile NFsM (PPy/PAN NFsM), and the eluent was directly analyzed by high-performance liquid chromatography-diode array detection (HPLC-DAD). The limits of detection (LODs) were between 0.002 and 0.01 mg kg -1 , and satisfactory linearity with correlation coefficients (R > 0.99) for each dye in all samples was achieved. Compared with the Chinese standard method and the published methods, the proposed method was simplified greatly with much lower requirement of sorbent (5.0 mg) and organic solvent (2.8 mL) and higher sample preparation speed (10 min/sample), while higher recovery (83.6-116.5%) and precision (RSDs < 7.1%) were obtained. With this developed method, we have successfully detected illegal ionic dyes in three common representative foods: yellow croaker, soybean products, and chili seasonings. Graphical abstract Schematic representation of the process of the three-step sample preparation.

  7. A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling

    International Nuclear Information System (INIS)

    Iida, Hidehiro; Itoh, Hiroshi; Bloomfield, P.M.; Munaka, Masahiro; Higano, Shuichi; Murakami, Matsutaro; Inugami, Atsushi; Eberl, S.; Aizawa, Yasuo; Kanno, Iwao; Uemura, Kazuo

    1994-01-01

    A method has been developed to quantitate regional cerebral blood blow (rCBF) using iodine-123-labelled N-isopropyl-p-iodoamphetamine (IMP). This technique requires only two single-photon emission tomography (SPET) scans and one blood sample. Based on a two-compartment model, radioactivity concentrations in the brain for each scan time are calculated. A standard input function has been generated by combining the input functions from 12 independent studies prior to this work to avoid frequent arterial blood sampling, and one blood sample is taken at 10 min following IMP administration for calibration of the standard arterial input function. This calibration time was determined such that the integration of the first 40 min of the calibrated, combined input function agreed best with those from 12 individual input functions (the difference was 5.3% on average). This method was applied to eight subjects (two normals and six patients with cerebral infarction), and yielded rCBF values which agreed well with those obtained by a positron emission tomography H 2 15 O autoradiography method. This method was also found to provide rCBF values that were consistent with those obtained by the non-linear least squares fitting technique and those obtained by conventional microsphere model analysis. The optimum SPET scan times were found to be 40 and 180 min for the early and delayed scans, respectively. These scan times allow the use of a conventional rotating gamma camera for clinical purposes. V d values ranged between 10 and 40 ml/g depending on the pathological condition, thereby suggesting the importance of measuring V d for each ROI. In conclusion, optimization of the blood sampling time and the scanning time enabled quantitative measurement of rCBF with two SPET scans and one blood sample. (orig.)

  8. Two-Sample Statistics for Testing the Equality of Survival Functions Against Improper Semi-parametric Accelerated Failure Time Alternatives: An Application to the Analysis of a Breast Cancer Clinical Trial

    Science.gov (United States)

    BROËT, PHILIPPE; TSODIKOV, ALEXANDER; DE RYCKE, YANN; MOREAU, THIERRY

    2010-01-01

    This paper presents two-sample statistics suited for testing equality of survival functions against improper semi-parametric accelerated failure time alternatives. These tests are designed for comparing either the short- or the long-term effect of a prognostic factor, or both. These statistics are obtained as partial likelihood score statistics from a time-dependent Cox model. As a consequence, the proposed tests can be very easily implemented using widely available software. A breast cancer clinical trial is presented as an example to demonstrate the utility of the proposed tests. PMID:15293627

  9. Two-sample statistics for testing the equality of survival functions against improper semi-parametric accelerated failure time alternatives: an application to the analysis of a breast cancer clinical trial.

    Science.gov (United States)

    Broët, Philippe; Tsodikov, Alexander; De Rycke, Yann; Moreau, Thierry

    2004-06-01

    This paper presents two-sample statistics suited for testing equality of survival functions against improper semi-parametric accelerated failure time alternatives. These tests are designed for comparing either the short- or the long-term effect of a prognostic factor, or both. These statistics are obtained as partial likelihood score statistics from a time-dependent Cox model. As a consequence, the proposed tests can be very easily implemented using widely available software. A breast cancer clinical trial is presented as an example to demonstrate the utility of the proposed tests.

  10. Method to obtain platelet-rich plasma from rabbits (Oryctolagus cuniculus

    Directory of Open Access Journals (Sweden)

    Josiane M. Pazzini

    2016-01-01

    Full Text Available Abstract: Platelet-rich plasma (PRP is a product easy and inxpesnsive, and stands out to for its growth factors in tissue repair. To obtain PRP, centrifugation of whole blood is made with specific time and gravitational forces. Thus, the present work aimed to study a method of double centrifugation to obtain PRP in order to evaluate the effective increase of platelet concentration in the final product, the preparation of PRP gel, and to optimize preparation time of the final sample. Fifteen female White New Zealand rabbits underwent blood sampling for the preparation of PRP. Samples were separated in two sterile tubes containing sodium citrate. Tubes were submitted to the double centrifugation protocol, with lid closed and 1600 revolutions per minute (rpm for 10 minutes, resulting in the separation of red blood cells, plasma with platelets and leucocytes. After were opened and plasma was pipetted and transferred into another sterile tube. Plasma was centrifuged again at 2000rpm for 10 minutes; as a result it was split into two parts: on the top, consisting of platelet-poor plasma (PPP and at the bottom of the platelet button. Part of the PPP was discarded so that only 1ml remained in the tube along with the platelet button. This material was gently agitated to promote platelets resuspension and activated when added 0.3ml of calcium gluconate, resulting in PRP gel. Double centrifugation protocol was able to make platelet concentration 3 times higher in relation to the initial blood sample. The volume of calcium gluconate used for platelet activation was 0.3ml, and was sufficient to coagulate the sample. Coagulation time ranged from 8 to 20 minutes, with an average of 17.6 minutes. Therefore, time of blood centrifugation until to obtain PRP gel took only 40 minutes. It was concluded that PRP was successfully obtained by double centrifugation protocol, which is able to increase the platelet concentration in the sample compared with whole blood

  11. Entropic sampling in the path integral Monte Carlo method

    International Nuclear Information System (INIS)

    Vorontsov-Velyaminov, P N; Lyubartsev, A P

    2003-01-01

    We have extended the entropic sampling Monte Carlo method to the case of path integral representation of a quantum system. A two-dimensional density of states is introduced into path integral form of the quantum canonical partition function. Entropic sampling technique within the algorithm suggested recently by Wang and Landau (Wang F and Landau D P 2001 Phys. Rev. Lett. 86 2050) is then applied to calculate the corresponding entropy distribution. A three-dimensional quantum oscillator is considered as an example. Canonical distributions for a wide range of temperatures are obtained in a single simulation run, and exact data for the energy are reproduced

  12. Pulmonary function in portuguese firefighters

    OpenAIRE

    A G Almeida; R Duarte; L Mieiro; A C Paiva; A M Rodrigues; M H Almeida; C Bárbara

    2007-01-01

    Introduction: Portugal has had a high rate of forest fires in recent years. Inhaled wood smoke can have short- and long-term effects on the lung function of people exposed to it. Study objectives: To assess the lung function of active wildland (forest) firefighters. Methods: Cross-sectional study. A self-questionnaire on personal and work habits was used and spirometry values were obtained using Piko-6® for a 209 people sample. Results: We found a high rate of smoking (42.9%) and an 11.8% pre...

  13. Raman bands in Ag nanoparticles obtained in extract of Opuntia ficus-indica plant

    Science.gov (United States)

    Bocarando-Chacon, J.-G.; Cortez-Valadez, M.; Vargas-Vazquez, D.; Rodríguez Melgarejo, F.; Flores-Acosta, M.; Mani-Gonzalez, P. G.; Leon-Sarabia, E.; Navarro-Badilla, A.; Ramírez-Bon, R.

    2014-05-01

    Silver nanoparticles have been obtained in an extract of Opuntia ficus-indica plant. The size and distribution of nanoparticles were quantified by atomic force microscopy (AFM). The diameter was estimated to be about 15 nm. In addition, energy dispersive X-ray spectroscopy (EDX) peaks of silver were observed in these samples. Three Raman bands have been experimentally detected at 83, 110 and 160 cm-1. The bands at 83 and 110 cm-1 are assigned to the silver-silver Raman modes (skeletal modes) and the Raman mode located at 160 cm-1 has been assigned to breathing modes. Vibrational assignments of Raman modes have been carried out based on the Density Functional Theory (DFT) quantum mechanical calculation. Structural and vibrational properties for small Agn clusters with 2≤n≤9 were determined. Calculated Raman modes for small metal clusters have an approximation trend of Raman bands. These Raman bands were obtained experimentally for silver nanoparticles (AgNP).

  14. Nanocrystalline and ultrafine grain copper obtained by mechanical attrition

    Directory of Open Access Journals (Sweden)

    Rodolfo Rodríguez Baracaldo

    2010-01-01

    Full Text Available This article presents a method for the sample preparation and characterisation of bulk copper having grain size lower than 1 μm (ultra-fine grain and lower than 100 nm grain size (nanocrystalline. Copper is initially manufactured by a milling/alloying me- chanical method thereby obtaining a powder having a nanocrystalline structure which is then consolidated through a process of warm compaction at high pressure. Microstructural characterisation of bulk copper samples showed the evolution of grain size during all stages involved in obtaining it. The results led to determining the necessary conditions for achieving a wide range of grain sizes. Mechanical characterisation indicated an increase in microhardness to values of around 3.40 GPa for unconsolida- ted nanocrystalline powder. Compressivee strength was increased by reducing the grain size, thereby obtaining an elastic limit of 650 MPa for consolidated copper having a ~ 62 nm grain size.

  15. Geopolymer obtained from coal ash

    International Nuclear Information System (INIS)

    Conte, V.; Bissari, E.S.; Uggioni, E.; Bernardin, A.M.

    2011-01-01

    Geopolymers are three-dimensional alumino silicates that can be rapidly formed at low temperature from naturally occurring aluminosilicates with a structure similar to zeolites. In this work coal ash (Tractebel Energy) was used as source of aluminosilicate according a full factorial design in eight formulations with three factors (hydroxide type and concentration and temperature) and two-levels. The ash was dried and hydroxide was added according type and concentration. The geopolymer was poured into cylindrical molds, cured (14 days) and subjected to compression test. The coal ash from power plants belongs to the Si-Al system and thus can easily form geopolymers. The compression tests showed that it is possible to obtain samples with strength comparable to conventional Portland cement. As a result, temperature and molarity are the main factors affecting the compressive strength of the obtained geopolymer. (author)

  16. On a Robust MaxEnt Process Regression Model with Sample-Selection

    Directory of Open Access Journals (Sweden)

    Hea-Jung Kim

    2018-04-01

    Full Text Available In a regression analysis, a sample-selection bias arises when a dependent variable is partially observed as a result of the sample selection. This study introduces a Maximum Entropy (MaxEnt process regression model that assumes a MaxEnt prior distribution for its nonparametric regression function and finds that the MaxEnt process regression model includes the well-known Gaussian process regression (GPR model as a special case. Then, this special MaxEnt process regression model, i.e., the GPR model, is generalized to obtain a robust sample-selection Gaussian process regression (RSGPR model that deals with non-normal data in the sample selection. Various properties of the RSGPR model are established, including the stochastic representation, distributional hierarchy, and magnitude of the sample-selection bias. These properties are used in the paper to develop a hierarchical Bayesian methodology to estimate the model. This involves a simple and computationally feasible Markov chain Monte Carlo algorithm that avoids analytical or numerical derivatives of the log-likelihood function of the model. The performance of the RSGPR model in terms of the sample-selection bias correction, robustness to non-normality, and prediction, is demonstrated through results in simulations that attest to its good finite-sample performance.

  17. Accounting for the thermal neutron flux depression in voluminous samples for instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Overwater, R.M.W.; Hoogenboom, J.E.

    1994-01-01

    At the Delft University of Technology Interfaculty Reactor Institute, a facility has been installed to irradiate cylindrical samples with diameters up to 15 cm and weights up to 50 kg for instrumental neutron activation analysis (INAA) purposes. To be able to do quantitative INAA on voluminous samples, it is necessary to correct for gamma-ray absorption, gamma-ray scattering, neutron absorption, and neutron scattering in the sample. The neutron absorption and the neutron scattering are discussed. An analytical solution is obtained for the diffusion equation in the geometry of the irradiation facility. For samples with known composition, the neutron flux--as a function of position in the sample--can be calculated directly. Those of unknown composition require additional flux measurements on which least-squares fitting must be done to obtain both the thermal neutron diffusion coefficient D s and the diffusion length L s of the sample. Experiments are performed to test the theory

  18. Fitting by a pearson II function of the spatial deposited energy distribution in superconducting YBaCuO samples calculated by Monte Carlo simulation

    International Nuclear Information System (INIS)

    Cruz Inclan, Carlos M.; Leyva Fabelo, Antonio; Alfonso Vazquez, Onexis

    2001-01-01

    The spatial deposited energy distribution inside YBa 2 Cu 3 O 7 superconducting ceramics irradiated with gamma rays were simulated using the codes system EGS4, based on the Monte Carlo method. The obtained distributions evidence a notable inhomogeneity, which may be one of the possible sources of inconsistent results of irradiation studies. The profiles of these distributions show asymmetrical behaviors, which may be fitted satisfactorily through a Pearson II Gamma type function. These fittings are presented in the paper and the behavior of the fitting parameters with the energy of incident photons, its number, and the experimental geometry were studied. The physical signification of each fitting parameters is discussed in the text. The exponent is related to certain mass absorption coefficient when the thick of the sample is sufficiently large

  19. Thermal diffusivity and electron transport properties of NTC samples obtained by the photoacoustic method

    International Nuclear Information System (INIS)

    Savic, S.M.; Aleksic, O.S.; Nikolic, M.V.; Lukovic, D.T.; Pejovic, V.Z.; Nikolic, P.M.

    2006-01-01

    Thermal diffusivity and electron transport parameters of sintered NTC samples were determined by the photoacoustic (PA) technique. Powder mixtures composed of MnO, NiO, CoO and Fe 2 O 3 were milled to nanometer particle size. NTC discs were dry powder pressed and sintered at different temperatures in the range from 900 deg. C to 1300 deg. C for 30 min. A second group of NTC discs was sintered at 1200 deg. C with the sintering time varying from 30 min to 360 min. These NTC samples were polished and exposed to a chopped laser beam in order to plot a response in the acoustic range. The thermal diffusivity of sintered NTC layers based on a metal oxide powder mixture was measured at room temperature by the photoacoustic technique. An increase of thermal diffusivity with the sintering temperature and time of sintering was observed

  20. Thermal diffusivity and electron transport properties of NTC samples obtained by the photoacoustic method

    Energy Technology Data Exchange (ETDEWEB)

    Savic, S.M. [Institute of Technical Sciences of SASA, Knez Mihailova 35/IV, 11000 Belgrade (Serbia); Aleksic, O.S. [Center for Multidisciplinary Studies of the University of Belgrade, Kneza Viseslava 1, 11000 Belgrade (Serbia); Nikolic, M.V. [Center for Multidisciplinary Studies of the University of Belgrade, Kneza Viseslava 1, 11000 Belgrade (Serbia); Lukovic, D.T. [Institute of Technical Sciences of SASA, Knez Mihailova 35/IV, 11000 Belgrade (Serbia); Pejovic, V.Z. [Center for Multidisciplinary Studies of the University of Belgrade, Kneza Viseslava 1, 11000 Belgrade (Serbia); Nikolic, P.M. [Institute of Technical Sciences of SASA, Knez Mihailova 35/IV, 11000 Belgrade (Serbia)]. E-mail: nikolic@sanu.ac.yu

    2006-07-15

    Thermal diffusivity and electron transport parameters of sintered NTC samples were determined by the photoacoustic (PA) technique. Powder mixtures composed of MnO, NiO, CoO and Fe{sub 2}O{sub 3} were milled to nanometer particle size. NTC discs were dry powder pressed and sintered at different temperatures in the range from 900 deg. C to 1300 deg. C for 30 min. A second group of NTC discs was sintered at 1200 deg. C with the sintering time varying from 30 min to 360 min. These NTC samples were polished and exposed to a chopped laser beam in order to plot a response in the acoustic range. The thermal diffusivity of sintered NTC layers based on a metal oxide powder mixture was measured at room temperature by the photoacoustic technique. An increase of thermal diffusivity with the sintering temperature and time of sintering was observed.

  1. A Note on Confidence Interval for the Power of the One Sample Test

    Directory of Open Access Journals (Sweden)

    A. Wong

    2010-01-01

    Full Text Available In introductory statistics texts, the power of the test of a one-sample mean when the variance is known is widely discussed. However, when the variance is unknown, the power of the Student's -test is seldom mentioned. In this note, a general methodology for obtaining inference concerning a scalar parameter of interest of any exponential family model is proposed. The method is then applied to the one-sample mean problem with unknown variance to obtain a (1−100% confidence interval for the power of the Student's -test that detects the difference (−0. The calculations require only the density and the cumulative distribution functions of the standard normal distribution. In addition, the methodology presented can also be applied to determine the required sample size when the effect size and the power of a size test of mean are given.

  2. Does the heritability of cognitive abilities vary as a function of parental education? Evidence from a German twin sample.

    Science.gov (United States)

    Spengler, Marion; Gottschling, Juliana; Hahn, Elisabeth; Tucker-Drob, Elliot M; Harzer, Claudia; Spinath, Frank M

    2018-01-01

    A well-known hypothesis in the behavioral genetic literature predicts that the heritability of cognitive abilities is higher in the presence of higher socioeconomic contexts. However, studies suggest that the effect of socioeconomic status (SES) on the heritability of cognitive ability may not be universal, as it has mostly been demonstrated in the United States, but not in other Western nations. In the present study we tested whether the importance of genetic and environmental effects on cognitive abilities varies as a function of parental education in a German twin sample. Cognitive ability scores (general, verbal, and nonverbal) were obtained on 531 German twin pairs (192 monozygotic, 339 dizygotic, ranging from 7 to 14 years of age; Mage = 10.25, SD = 1.83). Data on parental education were available from mothers and fathers. Results for general cognitive ability and nonverbal ability indicated no significant gene x parental education interaction effect. For verbal ability, a significant nonshared environment (E) x parental education interaction was found in the direction of greater nonshared environmental influences on verbal abilities among children raised by more educated parents.

  3. The Work Role Functioning Questionnaire v2.0 Showed Consistent Factor Structure Across Six Working Samples

    DEFF Research Database (Denmark)

    Abma, Femke I.; Bültmann, Ute; Amick, Benjamin C.

    2017-01-01

    Objective: The Work Role Functioning Questionnaire v2.0 (WRFQ) is an outcome measure linking a persons’ health to the ability to meet work demands in the twenty-first century. We aimed to examine the construct validity of the WRFQ in a heterogeneous set of working samples in the Netherlands...

  4. The Work Role Functioning Questionnaire v2.0 Showed Consistent Factor Structure Across Six Working Samples

    NARCIS (Netherlands)

    Abma, F.I.; Bultmann, U.; Amick III, B.C.; Arends, I.; Dorland, P.A.; Flach, P.A.; Klink, J.J.L van der; Ven H.A., van de; Bjørner, J.B.

    2017-01-01

    Objective The Work Role Functioning Questionnaire v2.0 (WRFQ) is an outcome measure linking a persons’ health to the ability to meet work demands in the twenty-first century. We aimed to examine the construct validity of the WRFQ in a heterogeneous set of working samples in the Netherlands with

  5. A simple vibrating sample magnetometer for macroscopic samples

    Science.gov (United States)

    Lopez-Dominguez, V.; Quesada, A.; Guzmán-Mínguez, J. C.; Moreno, L.; Lere, M.; Spottorno, J.; Giacomone, F.; Fernández, J. F.; Hernando, A.; García, M. A.

    2018-03-01

    We here present a simple model of a vibrating sample magnetometer (VSM). The system allows recording magnetization curves at room temperature with a resolution of the order of 0.01 emu and is appropriated for macroscopic samples. The setup can be mounted with different configurations depending on the requirements of the sample to be measured (mass, saturation magnetization, saturation field, etc.). We also include here examples of curves obtained with our setup and comparison curves measured with a standard commercial VSM that confirms the reliability of our device.

  6. Effect of simulated sampling disturbance on creep behaviour of rock salt

    Science.gov (United States)

    Guessous, Z.; Gill, D. E.; Ladanyi, B.

    1987-10-01

    This article presents the results of an experimental study of creep behaviour of a rock salt under uniaxial compression as a function of prestrain, simulating sampling disturbance. The prestrain was produced by radial compressive loading of the specimens prior to creep testing. The tests were conducted on an artifical salt to avoid excessive scattering of the results. The results obtained from several series of single-stage creep tests show that, at short-term, the creep response of salt is strongly affected by the preloading history of samples. The nature of this effect depends upon the intensity of radial compressive preloading, and its magnitude is a function of the creep stress level. The effect, however, decreases with increasing plastic deformation, indicating that large creep strains may eventually lead to a complete loss of preloading memory.

  7. Optimized preparation of urine samples for two-dimensional electrophoresis and initial application to patient samples

    DEFF Research Database (Denmark)

    Lafitte, Daniel; Dussol, Bertrand; Andersen, Søren

    2002-01-01

    OBJECTIVE: We optimized of the preparation of urinary samples to obtain a comprehensive map of urinary proteins of healthy subjects and then compared this map with the ones obtained with patient samples to show that the pattern was specific of their kidney disease. DESIGN AND METHODS: The urinary...

  8. Sample Size Calculations for Population Size Estimation Studies Using Multiplier Methods With Respondent-Driven Sampling Surveys.

    Science.gov (United States)

    Fearon, Elizabeth; Chabata, Sungai T; Thompson, Jennifer A; Cowan, Frances M; Hargreaves, James R

    2017-09-14

    While guidance exists for obtaining population size estimates using multiplier methods with respondent-driven sampling surveys, we lack specific guidance for making sample size decisions. To guide the design of multiplier method population size estimation studies using respondent-driven sampling surveys to reduce the random error around the estimate obtained. The population size estimate is obtained by dividing the number of individuals receiving a service or the number of unique objects distributed (M) by the proportion of individuals in a representative survey who report receipt of the service or object (P). We have developed an approach to sample size calculation, interpreting methods to estimate the variance around estimates obtained using multiplier methods in conjunction with research into design effects and respondent-driven sampling. We describe an application to estimate the number of female sex workers in Harare, Zimbabwe. There is high variance in estimates. Random error around the size estimate reflects uncertainty from M and P, particularly when the estimate of P in the respondent-driven sampling survey is low. As expected, sample size requirements are higher when the design effect of the survey is assumed to be greater. We suggest a method for investigating the effects of sample size on the precision of a population size estimate obtained using multipler methods and respondent-driven sampling. Uncertainty in the size estimate is high, particularly when P is small, so balancing against other potential sources of bias, we advise researchers to consider longer service attendance reference periods and to distribute more unique objects, which is likely to result in a higher estimate of P in the respondent-driven sampling survey. ©Elizabeth Fearon, Sungai T Chabata, Jennifer A Thompson, Frances M Cowan, James R Hargreaves. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 14.09.2017.

  9. Nonlinear Dynamics of Cantilever-Sample Interactions in Atomic Force Microscopy

    Science.gov (United States)

    Cantrell, John H.; Cantrell, Sean A.

    2010-01-01

    The interaction of the cantilever tip of an atomic force microscope (AFM) with the sample surface is obtained by treating the cantilever and sample as independent systems coupled by a nonlinear force acting between the cantilever tip and a volume element of the sample surface. The volume element is subjected to a restoring force from the remainder of the sample that provides dynamical equilibrium for the combined systems. The model accounts for the positions on the cantilever of the cantilever tip, laser probe, and excitation force (if any) via a basis set of set of orthogonal functions that may be generalized to account for arbitrary cantilever shapes. The basis set is extended to include nonlinear cantilever modes. The model leads to a pair of coupled nonlinear differential equations that are solved analytically using a matrix iteration procedure. The effects of oscillatory excitation forces applied either to the cantilever or to the sample surface (or to both) are obtained from the solution set and applied to the to the assessment of phase and amplitude signals generated by various acoustic-atomic force microscope (A-AFM) modalities. The influence of bistable cantilever modes of on AFM signal generation is discussed. The effects on the cantilever-sample surface dynamics of subsurface features embedded in the sample that are perturbed by surface-generated oscillatory excitation forces and carried to the cantilever via wave propagation are accounted by the Bolef-Miller propagating wave model. Expressions pertaining to signal generation and image contrast in A-AFM are obtained and applied to amplitude modulation (intermittent contact) atomic force microscopy and resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM). The influence of phase accumulation in A-AFM on image contrast is discussed, as is the effect of hard contact and maximum nonlinearity regimes of A-AFM operation.

  10. Statistical distribution sampling

    Science.gov (United States)

    Johnson, E. S.

    1975-01-01

    Determining the distribution of statistics by sampling was investigated. Characteristic functions, the quadratic regression problem, and the differential equations for the characteristic functions are analyzed.

  11. A Transcriptome—Targeting EcoChip for Assessing Functional Mycodiversity

    Directory of Open Access Journals (Sweden)

    Derek Peršoh

    2011-10-01

    Full Text Available A functional biodiversity microarray (EcoChip prototype has been developed to facilitate the analysis of fungal communities in environmental samples with broad functional and phylogenetic coverage and to enable the incorporation of nucleic acid sequence data as they become available from large-scale (next generation sequencing projects. A dual probe set (DPS was designed to detect a functional enzyme transcripts at conserved protein sites and b phylogenetic barcoding transcripts at ITS regions present in precursor rRNA. Deviating from the concept of GeoChip-type microarrays, the presented EcoChip microarray phylogenetic information was obtained using a dedicated set of barcoding microarray probes, whereas functional gene expression was analyzed by conserved domain-specific probes. By unlinking these two target groups, the shortage of broad sequence information of functional enzyme-coding genes in environmental communities became less important. The novel EcoChip microarray could be successfully applied to identify specific degradation activities in environmental samples at considerably high phylogenetic resolution. Reproducible and unbiased microarray signals could be obtained with chemically labeled total RNA preparations, thus avoiding the use of enzymatic labeling steps. ITS precursor rRNA was detected for the first time in a microarray experiment, which confirms the applicability of the EcoChip concept to selectively quantify the transcriptionally active part of fungal communities at high phylogenetic resolution. In addition, the chosen microarray platform facilitates the conducting of experiments with high sample throughput in almost any molecular biology laboratory.

  12. A Improved Seabed Surface Sand Sampling Device

    Science.gov (United States)

    Luo, X.

    2017-12-01

    In marine geology research it is necessary to obtain a suf fcient quantity of seabed surface samples, while also en- suring that the samples are in their original state. Currently,there are a number of seabed surface sampling devices available, but we fnd it is very diffcult to obtain sand samples using these devices, particularly when dealing with fne sand. Machine-controlled seabed surface sampling devices are also available, but generally unable to dive into deeper regions of water. To obtain larger quantities of seabed surface sand samples in their original states, many researchers have tried to improve upon sampling devices,but these efforts have generally produced ambiguous results, in our opinion.To resolve this issue, we have designed an improved andhighly effective seabed surface sand sampling device that incorporates the strengths of a variety of sampling devices. It is capable of diving into deepwater to obtain fne sand samples and is also suited for use in streams, rivers, lakes and seas with varying levels of depth (up to 100 m). This device can be used for geological mapping, underwater prospecting, geological engineering and ecological, environmental studies in both marine and terrestrial waters.

  13. Testing a groundwater sampling tool: Are the samples representative?

    International Nuclear Information System (INIS)

    Kaback, D.S.; Bergren, C.L.; Carlson, C.A.; Carlson, C.L.

    1989-01-01

    A ground water sampling tool, the HydroPunch trademark, was tested at the Department of Energy's Savannah River Site in South Carolina to determine if representative ground water samples could be obtained without installing monitoring wells. Chemical analyses of ground water samples collected with the HydroPunch trademark from various depths within a borehole were compared with chemical analyses of ground water from nearby monitoring wells. The site selected for the test was in the vicinity of a large coal storage pile and a coal pile runoff basin that was constructed to collect the runoff from the coal storage pile. Existing monitoring wells in the area indicate the presence of a ground water contaminant plume that: (1) contains elevated concentrations of trace metals; (2) has an extremely low pH; and (3) contains elevated concentrations of major cations and anions. Ground water samples collected with the HydroPunch trademark provide in excellent estimate of ground water quality at discrete depths. Groundwater chemical data collected from various depths using the HydroPunch trademark can be averaged to simulate what a screen zone in a monitoring well would sample. The averaged depth-discrete data compared favorably with the data obtained from the nearby monitoring wells

  14. Low temperature X-ray diffraction studies of natural gas hydrate samples from the Gulf of Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Rawn, C.J. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Materials Science and Technology Div.; Sassen, R. [Texas A and M Univ., College Station, TX (United States). Geochemical and Environmental Research Group; Ulrich, S.M.; Phelps, T.J. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Biosciences Div.; Chakoumakos, B.C. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Neutron Scattering Science Div.; Payzant, E.A. [Oak Ridge National Laboratory, Oak Ridge, TN (United States). Center for Nanophase Materials Science

    2008-07-01

    Quantitative studies of natural clathrate hydrates are hampered by the difficulties associated with obtaining pristine samples for the sea floor without comprising their integrity. This paper discussed X-ray power diffraction studies conducted to measure natural gas hydrate samples obtained from the Green Canyon in the Gulf of Mexico. Data on the hydrate deposits were initially collected in 2002. The X-ray diffraction data were collected in order to examine the structure 2 (s2) gas hydrates as functions of temperature and time. A diffractometer with a theta-theta goniometer modified with a helium closed cycle refrigerator and temperature controller was used. Aragonite, quartz and halite phases were determined in the decomposed sample. Refined phase fractions for both the ice and the s2 hydrate were obtained as a function of temperature. Results of the study demonstrated that the amount of hydrates decreased with increasing temperatures and amounts of time. Large pieces of the hydrate showed heterogenous ice content. Dissociation rates were higher at lower temperatures. It was concluded that unusual trends observed for the smaller lattice parameter of the hydrates resulted from the formation of ice layers that acted as barriers to the released gases and caused increased isostatic pressures around the hydrate core. 9 refs., 6 figs.

  15. Are old people so gentle? Functional and dysfunctional impulsivity in the elderly.

    Science.gov (United States)

    Morales-Vives, Fabia; Vigil-Colet, Andreu

    2012-03-01

    Although old people may seem less impulsive than adults, numerous experimental studies report that they have inhibitory deficits. Bearing in mind that there is a relationship between inhibition processes and impulsivity, age-related inhibition deficits suggest that older people could be more impulsive than adults. The aim of the current study was to compare the functional and dysfunctional impulsivity scores obtained in a sample of elderly people (65 years old and above) with those obtained in previous studies on samples of adolescents and adults. Dickman's Impulsivity Inventory was administered to 190 individuals aged between 65 and 94 years without dementia or cognitive impairment. Results indicated that the elderly sample showed higher dysfunctional impulsivity levels than the adult samples, which is consistent with the inhibition deficits mentioned above. There were no significant differences in functional impulsivity. Furthermore, old women had higher scores than old men on dysfunctional impulsivity. This study provides evidence of age-related changes in dysfunctional impulsivity. Functional impulsivity did not show the same pattern as dysfunctional impulsivity, being quite stable across the age span. it seems, then, that impulsivity cannot be considered to decrease with age and dysfunctional impulsivity may even increase.

  16. Fully automated calculation of image-derived input function in simultaneous PET/MRI in a sheep model

    International Nuclear Information System (INIS)

    Jochimsen, Thies H.; Zeisig, Vilia; Schulz, Jessica; Werner, Peter; Patt, Marianne; Patt, Jörg; Dreyer, Antje Y.; Boltze, Johannes; Barthel, Henryk; Sabri, Osama; Sattler, Bernhard

    2016-01-01

    Obtaining the arterial input function (AIF) from image data in dynamic positron emission tomography (PET) examinations is a non-invasive alternative to arterial blood sampling. In simultaneous PET/magnetic resonance imaging (PET/MRI), high-resolution MRI angiographies can be used to define major arteries for correction of partial-volume effects (PVE) and point spread function (PSF) response in the PET data. The present study describes a fully automated method to obtain the image-derived input function (IDIF) in PET/MRI. Results are compared to those obtained by arterial blood sampling. To segment the trunk of the major arteries in the neck, a high-resolution time-of-flight MRI angiography was postprocessed by a vessel-enhancement filter based on the inertia tensor. Together with the measured PSF of the PET subsystem, the arterial mask was used for geometrical deconvolution, yielding the time-resolved activity concentration averaged over a major artery. The method was compared to manual arterial blood sampling at the hind leg of 21 sheep (animal stroke model) during measurement of blood flow with O15-water. Absolute quantification of activity concentration was compared after bolus passage during steady state, i.e., between 2.5- and 5-min post injection. Cerebral blood flow (CBF) values from blood sampling and IDIF were also compared. The cross-calibration factor obtained by comparing activity concentrations in blood samples and IDIF during steady state is 0.98 ± 0.10. In all examinations, the IDIF provided a much earlier and sharper bolus peak than in the time course of activity concentration obtained by arterial blood sampling. CBF using the IDIF was 22 % higher than CBF obtained by using the AIF yielded by blood sampling. The small deviation between arterial blood sampling and IDIF during steady state indicates that correction of PVE and PSF is possible with the method presented. The differences in bolus dynamics and, hence, CBF values can be explained by the

  17. Fully automated calculation of image-derived input function in simultaneous PET/MRI in a sheep model

    Energy Technology Data Exchange (ETDEWEB)

    Jochimsen, Thies H.; Zeisig, Vilia [Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig (Germany); Schulz, Jessica [Max Planck Institute for Human Cognitive and Brain Sciences, Stephanstr. 1a, Leipzig, D-04103 (Germany); Werner, Peter; Patt, Marianne; Patt, Jörg [Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig (Germany); Dreyer, Antje Y. [Fraunhofer Institute of Cell Therapy and Immunology, Perlickstr. 1, Leipzig, D-04103 (Germany); Translational Centre for Regenerative Medicine, University Leipzig, Philipp-Rosenthal-Str. 55, Leipzig, D-04103 (Germany); Boltze, Johannes [Fraunhofer Institute of Cell Therapy and Immunology, Perlickstr. 1, Leipzig, D-04103 (Germany); Translational Centre for Regenerative Medicine, University Leipzig, Philipp-Rosenthal-Str. 55, Leipzig, D-04103 (Germany); Fraunhofer Research Institution of Marine Biotechnology and Institute for Medical and Marine Biotechnology, University of Lübeck, Lübeck (Germany); Barthel, Henryk; Sabri, Osama; Sattler, Bernhard [Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig (Germany)

    2016-02-13

    Obtaining the arterial input function (AIF) from image data in dynamic positron emission tomography (PET) examinations is a non-invasive alternative to arterial blood sampling. In simultaneous PET/magnetic resonance imaging (PET/MRI), high-resolution MRI angiographies can be used to define major arteries for correction of partial-volume effects (PVE) and point spread function (PSF) response in the PET data. The present study describes a fully automated method to obtain the image-derived input function (IDIF) in PET/MRI. Results are compared to those obtained by arterial blood sampling. To segment the trunk of the major arteries in the neck, a high-resolution time-of-flight MRI angiography was postprocessed by a vessel-enhancement filter based on the inertia tensor. Together with the measured PSF of the PET subsystem, the arterial mask was used for geometrical deconvolution, yielding the time-resolved activity concentration averaged over a major artery. The method was compared to manual arterial blood sampling at the hind leg of 21 sheep (animal stroke model) during measurement of blood flow with O15-water. Absolute quantification of activity concentration was compared after bolus passage during steady state, i.e., between 2.5- and 5-min post injection. Cerebral blood flow (CBF) values from blood sampling and IDIF were also compared. The cross-calibration factor obtained by comparing activity concentrations in blood samples and IDIF during steady state is 0.98 ± 0.10. In all examinations, the IDIF provided a much earlier and sharper bolus peak than in the time course of activity concentration obtained by arterial blood sampling. CBF using the IDIF was 22 % higher than CBF obtained by using the AIF yielded by blood sampling. The small deviation between arterial blood sampling and IDIF during steady state indicates that correction of PVE and PSF is possible with the method presented. The differences in bolus dynamics and, hence, CBF values can be explained by the

  18. Use of semiconductor detector c-Si microstrip type in obtaining the digital radiographic imaging of phantoms and biological samples of mammary glands

    International Nuclear Information System (INIS)

    Leyva, A.; Cabal, A.; Pinera, I.; Abreu, Y.; Cruz, C. M.; Montano, L. M.; Diaz, C. C.; Fontaine, M.; Ortiz, C. M.; Padilla, F.; De la Mora, R.

    2009-01-01

    The present work synthesizes the experimental results obtained in the characterization of 64 micro strips crystalline silicon detector designed for experiments in high energies physics, with the objective of studying its possible application in advanced medical radiography, specifically in digital mammography and angiography. The research includes the acquisition of two-dimensional radiography of a mammography phantom using the scanning method, and its comparison with similar images simulated mathematically for different X rays sources. The paper also shows the experimental radiography of two biological samples taken from biopsies of mammas, where it is possible to identify the presence of possible pathological lesions. The results reached in this work point positively toward the effective possibility of satisfactorily introducing those advanced detectors in medical digital imaging applications. (Author)

  19. Sampling considerations when analyzing micrometric-sized particles in a liquid jet using laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Faye, C.B.; Amodeo, T.; Fréjafon, E. [Institut National de l' Environnement Industriel et des Risques (INERIS/DRC/CARA/NOVA), Parc Technologique Alata, BP 2, 60550 Verneuil-En-Halatte (France); Delepine-Gilon, N. [Institut des Sciences Analytiques, 5 rue de la Doua, 69100 Villeurbanne (France); Dutouquet, C., E-mail: christophe.dutouquet@ineris.fr [Institut National de l' Environnement Industriel et des Risques (INERIS/DRC/CARA/NOVA), Parc Technologique Alata, BP 2, 60550 Verneuil-En-Halatte (France)

    2014-01-01

    Pollution of water is a matter of concern all over the earth. Particles are known to play an important role in the transportation of pollutants in this medium. In addition, the emergence of new materials such as NOAA (Nano-Objects, their Aggregates and their Agglomerates) emphasizes the need to develop adapted instruments for their detection. Surveillance of pollutants in particulate form in waste waters in industries involved in nanoparticle manufacturing and processing is a telling example of possible applications of such instrumental development. The LIBS (laser-induced breakdown spectroscopy) technique coupled with the liquid jet as sampling mode for suspensions was deemed as a potential candidate for on-line and real time monitoring. With the final aim in view to obtain the best detection limits, the interaction of nanosecond laser pulses with the liquid jet was examined. The evolution of the volume sampled by laser pulses was estimated as a function of the laser energy applying conditional analysis when analyzing a suspension of micrometric-sized particles of borosilicate glass. An estimation of the sampled depth was made. Along with the estimation of the sampled volume, the evolution of the SNR (signal to noise ratio) as a function of the laser energy was investigated as well. Eventually, the laser energy and the corresponding fluence optimizing both the sampling volume and the SNR were determined. The obtained results highlight intrinsic limitations of the liquid jet sampling mode when using 532 nm nanosecond laser pulses with suspensions. - Highlights: • Micrometric-sized particles in suspensions are analyzed using LIBS and a liquid jet. • The evolution of the sampling volume is estimated as a function of laser energy. • The sampling volume happens to saturate beyond a certain laser fluence. • Its value was found much lower than the beam diameter times the jet thickness. • Particles proved not to be entirely vaporized.

  20. New mechanical chemical equilibrium in the copper-zinc alloys obtained by mechanical alloying

    International Nuclear Information System (INIS)

    Dianez, M.J; Criado, J.M; Donoso, E; Diaz, G

    2006-01-01

    A series of copper zinc alloys have been synthesized in the entire composition range Cu10Zn to Cu70Zn respectively, by mechanical alloying at room temperature in a planetary high-energy mill. A mechanism is proposed for the mechanical alloying reaction of the copper and zinc. It is made clear that the mechanical treatment considerably extends the range of composition of the α phase up to a content of 41% zinc, instead of the 36% accepted by the conventional phase diagrams. Exact determinations of the phase α reticular parameter were carried out as a function of its composition which can be used to determine the zinc content of the brass α. The results show that a brass phase α may be obtained containing 49% zinc in samples that include a mixture of phases α and β' after reaching stationary state as a function of the milling time. The stability field of phases β' and γ also displace noticeably higher values than those expected from the conventional binary Cu-Zn diagram. This behavior has been explained as a function of the nanometric texture generated by the milling (CW)

  1. Obtaining the Varshni potential function using the 2-body Kaxiras–Pandey parameters

    Directory of Open Access Journals (Sweden)

    TEIK-CHENG LIM

    2009-12-01

    Full Text Available A generalized version of the Varshni potential function was adopted by Kaxiras and Pandey for describing the 2-body energy portion of multi-body condensed matter. The former’s simplicity and resemblance to a Morse potential allows faster computation while the latter’s greater number of parameters allows better curve-fitting of spectroscopic data. This paper shows one set of parameter conversion from the Varshni function to the 2-body portion of the Kaxiras–Pandey function, and vice versa two sets of parameter conversion. The latter two sets reveal good correlation between plotted curves, and were verified by the imposition of equal energy curvatures at equilibrium and equal energy integral from equilibrium to dissociation. These parameter conversions can also be attained more easily by equating the product of indices (for short range and the summation of index reciprocals (for long range.

  2. Assessment of crystalline disorder in cryo-milled samples of indomethacin using atomic pair-wise distribution functions

    DEFF Research Database (Denmark)

    Bøtker, Johan P; Karmwar, Pranav; Strachan, Clare J

    2011-01-01

    to analyse the cryo-milled samples. The high similarity between the ¿-indomethacin cryogenic ball milled samples and the crude ¿-indomethacin indicated that milled samples retained residual order of the ¿-form. The PDF analysis encompassed the capability of achieving a correlation with the physical......The aim of this study was to investigate the usefulness of the atomic pair-wise distribution function (PDF) to detect the extension of disorder/amorphousness induced into a crystalline drug using a cryo-milling technique, and to determine the optimal milling times to achieve amorphisation. The PDF...... properties determined from DSC, ss-NMR and stability experiments. Multivariate data analysis (MVDA) was used to visualize the differences in the PDF and XRPD data. The MVDA approach revealed that PDF is more efficient in assessing the introduced degree of disorder in ¿-indomethacin after cryo-milling than...

  3. Effect of Leisure Activities on Inflammation and Cognitive Function in an Aging Sample

    Science.gov (United States)

    Friedman, Elliot; Quinn, Jill; Chen, Ding-Geng (Din); Mapstone, Mark

    2012-01-01

    Cardiovascular disease risk factors (CVDRFs) increase the risk of dementia. The purpose of this study was to examine whether leisure activities (mental, physical, and social activities) modified the effect of CVDRFs on inflammatory markers and cognitive function in middle and old age. A secondary-data analysis study was conducted using data from 405 middle-age participants (40 –59 years) and 342 old-age participants (60 – 84 years) who participated in the Survey of Midlife Development in the United States. CVDRFs were obtained from a combination of self-report medical history and blood-based biomarkers. Three CVDRF groups (≤1, 2, and ≥3 CVDRFs) were identified. More CVDRFs were significantly associated with higher levels of inflammatory markers in both age groups, and associated with lower levels of executive function in the old age group. CVDRFs were not related to the frequency of leisure activities in either age group. After controlling for covariates, higher levels of physical activities were significantly associated with lower levels of inflammatory markers, and higher levels of mental activities were associated with higher levels of cognitive function. In the old age group, physical activities also moderated the effect of CVDRFs on episodic memory, and mental activities moderated the effect of CVDRFs on interleukin-6. Multiple CVDRFs may be associated with poorer cognitive function and higher inflammatory markers, but middle-age and older adults with CVDRFs may not engage in frequent physical and cognitive activities that may be protective. It is important to develop strategies to facilitate engagement in these activities from midlife. PMID:22377120

  4. Methodological effects in Fourier transform infrared (FTIR) spectroscopy: Implications for structural analyses of biomacromolecular samples

    Science.gov (United States)

    Kamnev, Alexander A.; Tugarova, Anna V.; Dyatlova, Yulia A.; Tarantilis, Petros A.; Grigoryeva, Olga P.; Fainleib, Alexander M.; De Luca, Stefania

    2018-03-01

    A set of experimental data obtained by Fourier transform infrared (FTIR) spectroscopy (involving the use of samples ground and pressed with KBr, i.e. in a polar halide matrix) and by matrix-free transmission FTIR or diffuse reflectance infrared Fourier transform (DRIFT) spectroscopic methodologies (involving measurements of thin films or pure powdered samples, respectively) were compared for several different biomacromolecular substances. The samples under study included poly-3-hydroxybutyrate (PHB) isolated from cell biomass of the rhizobacterium Azospirillum brasilense; dry PHB-containing A. brasilense biomass; pectin (natural carboxylated heteropolysaccharide of plant origin; obtained from apple peel) as well as its chemically modified derivatives obtained by partial esterification of its galacturonide-chain hydroxyl moieties with palmitic, oleic and linoleic acids. Significant shifts of some FTIR vibrational bands related to polar functional groups of all the biomacromolecules under study, induced by the halide matrix used for preparing the samples for spectroscopic measurements, were shown and discussed. A polar halide matrix used for preparing samples for FTIR measurements was shown to be likely to affect band positions not only per se, by affecting band energies or via ion exchange (e.g., with carboxylate moieties), but also by inducing crystallisation of metastable amorphous biopolymers (e.g., PHB of microbial origin). The results obtained have important implications for correct structural analyses of polar, H-bonded and/or amphiphilic biomacromolecular systems using different methodologies of FTIR spectroscopy.

  5. Interfacial adhesion of laser clad functionally graded materials

    NARCIS (Netherlands)

    Pei, Y. T.; Ocelik, V.; De Hosson, J. T. M.

    2003-01-01

    Specially designed samples of laser clad AlSi40 functionally graded materials (FGM) are made for evaluating the interfacial adhesion. To obtain the interfacial bond strength notches are made right at the interface of the FGMs. In-situ microstructural observations during straining in a field-emission

  6. Interfacial adhesion of laser clad functionally graded materials

    NARCIS (Netherlands)

    De Hosson, JTM; Pei, YT; Ocelik, [No Value; Sudarshan, TS; Stiglich, JJ; Jeandin, M

    2002-01-01

    Specially designed samples of laser clad AlSi40 functionally graded materials (FGM) are made for evaluating the interfacial adhesion. To obtain the interfacial bond strength notches are made right at the interface of the FGMs. In-sitit microstructural observations during straining in an FEG-ESEM

  7. SIPPI: A Matlab toolbox for sampling the solution to inverse problems with complex prior information

    DEFF Research Database (Denmark)

    Hansen, Thomas Mejer; Cordua, Knud Skou; Looms, Majken Caroline

    2013-01-01

    We present an application of the SIPPI Matlab toolbox, to obtain a sample from the a posteriori probability density function for the classical tomographic inversion problem. We consider a number of different forward models, linear and non-linear, such as ray based forward models that rely...

  8. Testing results of Monte Carlo sampling processes in MCSAD

    International Nuclear Information System (INIS)

    Pinnera, I.; Cruz, C.; Abreu, Y.; Leyva, A.; Correa, C.; Demydenko, C.

    2009-01-01

    The Monte Carlo Simulation of Atom Displacements (MCSAD) is a code implemented by the authors to simulate the complete process of atom displacement (AD) formation. This code makes use of the Monte Carlo (MC) method to sample all the processes involved in the gamma and electronic radiation transport through matter. The kernel of the calculations applied to this code relies on a model based on an algorithm developed by the authors, which firstly splits out multiple electron elastic scattering events from those single ones at higher scattering angles and then, from the last one, sampling those leading to AD at high transferred atomic recoil energies. Some tests have been developed to check the sampling algorithms with the help of the corresponding theoretical distribution functions. Satisfactory results have been obtained, which indicate the strength of the methods and subroutines used in the code. (Author)

  9. Enantiopure Functional Molecular Motors Obtained by a Switchable Chiral-Resolution Process

    NARCIS (Netherlands)

    van Leeuwen, Thomas; Gan, Jefri; Kistemaker, Jos C. M.; Pizzolato, Stefano F.; Chang, Mu-Chieh; Feringa, Ben L.

    2016-01-01

    Molecular switches, rotors, and motors play an important role in the development of nano-machines and devices, as well as responsive and adaptive functional materials. For unidirectional rotors based on chiral overcrowded alkenes, their stereochemical homogeneity is of crucial importance. Herein, a

  10. Large-scale prospective T cell function assays in shipped, unfrozen blood samples: experiences from the multicenter TRIGR trial.

    Science.gov (United States)

    Hadley, David; Cheung, Roy K; Becker, Dorothy J; Girgis, Rose; Palmer, Jerry P; Cuthbertson, David; Krischer, Jeffrey P; Dosch, Hans-Michael

    2014-02-01

    Broad consensus assigns T lymphocytes fundamental roles in inflammatory, infectious, and autoimmune diseases. However, clinical investigations have lacked fully characterized and validated procedures, equivalent to those of widely practiced biochemical tests with established clinical roles, for measuring core T cell functions. The Trial to Reduce Insulin-dependent diabetes mellitus in the Genetically at Risk (TRIGR) type 1 diabetes prevention trial used consecutive measurements of T cell proliferative responses in prospectively collected fresh heparinized blood samples shipped by courier within North America. In this article, we report on the quality control implications of this simple and pragmatic shipping practice and the interpretation of positive- and negative-control analytes in our assay. We used polyclonal and postvaccination responses in 4,919 samples to analyze the development of T cell immunocompetence. We have found that the vast majority of the samples were viable up to 3 days from the blood draw, yet meaningful responses were found in a proportion of those with longer travel times. Furthermore, the shipping time of uncooled samples significantly decreased both the viabilities of the samples and the unstimulated cell counts in the viable samples. Also, subject age was significantly associated with the number of unstimulated cells and T cell proliferation to positive activators. Finally, we observed a pattern of statistically significant increases in T cell responses to tetanus toxin around the timing of infant vaccinations. This assay platform and shipping protocol satisfy the criteria for robust and reproducible long-term measurements of human T cell function, comparable to those of established blood biochemical tests. We present a stable technology for prospective disease-relevant T cell analysis in immunological diseases, vaccination medicine, and measurement of herd immunity.

  11. Defining And Characterizing Sample Representativeness For DWPF Melter Feed Samples

    Energy Technology Data Exchange (ETDEWEB)

    Shine, E. P.; Poirier, M. R.

    2013-10-29

    statisticians used carefully thought out designs that systematically and economically provided plans for data collection from the DWPF process. Key shared features of the sampling designs used at DWPF and the Gy sampling methodology were the specification of a standard for sample representativeness, an investigation that produced data from the process to study the sampling function, and a decision framework used to assess whether the specification was met based on the data. Without going into detail with regard to the seven errors identified by Pierre Gy, as excellent summaries are readily available such as Pitard [1989] and Smith [2001], SRS engineers understood, for example, that samplers can be biased (Gy's extraction error), and developed plans to mitigate those biases. Experiments that compared installed samplers with more representative samples obtained directly from the tank may not have resulted in systematically partitioning sampling errors into the now well-known error categories of Gy, but did provide overall information on the suitability of sampling systems. Most of the designs in this report are related to the DWPF vessels, not the large SRS Tank Farm tanks. Samples from the DWPF Slurry Mix Evaporator (SME), which contains the feed to the DWPF melter, are characterized using standardized analytical methods with known uncertainty. The analytical error is combined with the established error from sampling and processing in DWPF to determine the melter feed composition. This composition is used with the known uncertainty of the models in the Product Composition Control System (PCCS) to ensure that the wasteform that is produced is comfortably within the acceptable processing and product performance region. Having the advantage of many years of processing that meets the waste glass product acceptance criteria, the DWPF process has provided a considerable amount of data about itself in addition to the data from many special studies. Demonstrating representative

  12. Defining And Characterizing Sample Representativeness For DWPF Melter Feed Samples

    International Nuclear Information System (INIS)

    Shine, E. P.; Poirier, M. R.

    2013-01-01

    statisticians used carefully thought out designs that systematically and economically provided plans for data collection from the DWPF process. Key shared features of the sampling designs used at DWPF and the Gy sampling methodology were the specification of a standard for sample representativeness, an investigation that produced data from the process to study the sampling function, and a decision framework used to assess whether the specification was met based on the data. Without going into detail with regard to the seven errors identified by Pierre Gy, as excellent summaries are readily available such as Pitard [1989] and Smith [2001], SRS engineers understood, for example, that samplers can be biased (Gy's extraction error), and developed plans to mitigate those biases. Experiments that compared installed samplers with more representative samples obtained directly from the tank may not have resulted in systematically partitioning sampling errors into the now well-known error categories of Gy, but did provide overall information on the suitability of sampling systems. Most of the designs in this report are related to the DWPF vessels, not the large SRS Tank Farm tanks. Samples from the DWPF Slurry Mix Evaporator (SME), which contains the feed to the DWPF melter, are characterized using standardized analytical methods with known uncertainty. The analytical error is combined with the established error from sampling and processing in DWPF to determine the melter feed composition. This composition is used with the known uncertainty of the models in the Product Composition Control System (PCCS) to ensure that the wasteform that is produced is comfortably within the acceptable processing and product performance region. Having the advantage of many years of processing that meets the waste glass product acceptance criteria, the DWPF process has provided a considerable amount of data about itself in addition to the data from many special studies. Demonstrating representative sampling

  13. Evaluation of Multiple-Sampling Function used with a Microtek flatbed scanner for Radiation Dosimetry Calibration of EBT2 Film

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Liyun [Department of Medical Imaging and Radiological Sciences, I-Shou University, Kaohsiung 82445, Taiwan (China); Ho, Sheng-Yow [Department of Nursing, Chang Jung Christian University, Tainan 71101, Taiwan (China); Department of Radiation Oncology, Chi Mei Medical Center, Liouying, Tainan 73657, Taiwan (China); Ding, Hueisch-Jy [Department of Medical Imaging and Radiological Sciences, I-Shou University, Kaohsiung 82445, Taiwan (China); Hwang, Ing-Ming [Department of Medical Imaging and Radiology, Shu Zen College of Medicine and Management, Kaohsiung 82144, Taiwan (China); Chen, Pang-Yu, E-mail: pangyuchen@yahoo.com.tw [Department of Radiation Oncology, Sinlau Christian Hospital, Tainan 70142, Taiwan (China); Lee, Tsair-Fwu, E-mail: tflee@kuas.edu.tw [Medical Physics and Informatics Laboratory, Department of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung 80778, Taiwan (China)

    2016-10-01

    The radiochromic EBT2 film is a widely used quality assurance device for radiation therapy. This study evaluated the film calibration performance of the multiple-sampling function, a function of the ScanWizard Pro scanning software provided by the manufacturer, when used with Microtek 9800XL plus (9800XL{sup +}) flatbed scanner. By using the PDD method, each one of the eight EBT2 films, four delivered by 290 monitor unit (MU) and four by 88 MU via 6-MV photon beams, was tightly sandwiched in a 30{sup 3}-cm{sup 3} water equivalent polystyrene phantom prior to irradiation. Before and after irradiation, all films were scanned using the Microtek 9800XL{sup +} scanner with five different modes of the multiple-sampling function, which could generate the image with the averaged result of multiple-sampling. The net optical densities (netOD) on the beam central axis of film were assigned to corresponding depth doses for calibration. For each sampling mode with either delivered MU, the depth-dose uncertainty of a single film from repeated scans and that of a single scan of the four films were analyzed. Finally, the calibration error and the combined calibration uncertainty between film determined depth-doses and delivered depth-doses were calculated and evaluated for each sampling mode. All standard deviations and the calibration error were demonstrated to be unrelated to the number of sampling lines. The calibration error of the 2-line and 16-line mode was within 3 cGy and better than that of the other modes. The combined uncertainty of the 2-line mode was the lowest, which was generally less than 6 cGy except for the delivered dose around 100 cGy. The evaluation described herein revealed that the EBT2 film calibrated with the 2-line mode has relatively lower error, scanning time and combined uncertianty. Therefore, it is recommended for routine EBT2 film calibration and verification of treatment plans.

  14. Evaluation of Multiple-Sampling Function used with a Microtek flatbed scanner for Radiation Dosimetry Calibration of EBT2 Film

    International Nuclear Information System (INIS)

    Chang, Liyun; Ho, Sheng-Yow; Ding, Hueisch-Jy; Hwang, Ing-Ming; Chen, Pang-Yu; Lee, Tsair-Fwu

    2016-01-01

    The radiochromic EBT2 film is a widely used quality assurance device for radiation therapy. This study evaluated the film calibration performance of the multiple-sampling function, a function of the ScanWizard Pro scanning software provided by the manufacturer, when used with Microtek 9800XL plus (9800XL + ) flatbed scanner. By using the PDD method, each one of the eight EBT2 films, four delivered by 290 monitor unit (MU) and four by 88 MU via 6-MV photon beams, was tightly sandwiched in a 30 3 -cm 3 water equivalent polystyrene phantom prior to irradiation. Before and after irradiation, all films were scanned using the Microtek 9800XL + scanner with five different modes of the multiple-sampling function, which could generate the image with the averaged result of multiple-sampling. The net optical densities (netOD) on the beam central axis of film were assigned to corresponding depth doses for calibration. For each sampling mode with either delivered MU, the depth-dose uncertainty of a single film from repeated scans and that of a single scan of the four films were analyzed. Finally, the calibration error and the combined calibration uncertainty between film determined depth-doses and delivered depth-doses were calculated and evaluated for each sampling mode. All standard deviations and the calibration error were demonstrated to be unrelated to the number of sampling lines. The calibration error of the 2-line and 16-line mode was within 3 cGy and better than that of the other modes. The combined uncertainty of the 2-line mode was the lowest, which was generally less than 6 cGy except for the delivered dose around 100 cGy. The evaluation described herein revealed that the EBT2 film calibrated with the 2-line mode has relatively lower error, scanning time and combined uncertianty. Therefore, it is recommended for routine EBT2 film calibration and verification of treatment plans.

  15. Process to Obtain Quick Counts from PREP

    Directory of Open Access Journals (Sweden)

    Martínez–Cruz M.Á.

    2011-10-01

    Full Text Available Considering the Preliminary Electoral Results Program (PERP as a database of the federal elections for president of the Mexican Republic, a methodology was developed in order to find representative samples of ballot boxes installed in the election’s day (quick count in different hours, due to its characteristics of gathering of information, the PREP in the first hours forms a non-representative sample of data. In a particular way, in the election of July 2, 2006, after 3 hours of opening the PREP, it was observed that the accuracy of the process of the quick counts was better than the one obtained by the IFE. Among other things, this allows to lower the cost, to increase the confidentiality of the ballot boxes used in the sampling and to distinguish in a precise moment the winning candidate long before PREP finishes.

  16. How to obtain J-R curve from one test on one sample

    International Nuclear Information System (INIS)

    Roche, Roland.

    1981-01-01

    Operational definition of J concept is first examined. Then it is shown that conventional methods of experimental determination of J values are based on the following assumption: if the load-deflexion curve is known for one value of the crack length it is possible to know the load-deflexion curve for any value of the crack length. This assumption is generalized with the help of scale functions and formula giving J are deduced. Attention is given to the effect of crack propagation on J values. The same assumption is used to extract the crack length from the load-deflexion curve. As the real crack lengths are known before propagation occurs and at the end of the test, it is possible to achieve a good calibration of the material characteristic [fr

  17. Adaptive sampling based on the cumulative distribution function of order statistics to delineate heavy-metal contaminated soils using kriging

    International Nuclear Information System (INIS)

    Juang, K.-W.; Lee, D.-Y.; Teng, Y.-L.

    2005-01-01

    Correctly classifying 'contaminated' areas in soils, based on the threshold for a contaminated site, is important for determining effective clean-up actions. Pollutant mapping by means of kriging is increasingly being used for the delineation of contaminated soils. However, those areas where the kriged pollutant concentrations are close to the threshold have a high possibility for being misclassified. In order to reduce the misclassification due to the over- or under-estimation from kriging, an adaptive sampling using the cumulative distribution function of order statistics (CDFOS) was developed to draw additional samples for delineating contaminated soils, while kriging. A heavy-metal contaminated site in Hsinchu, Taiwan was used to illustrate this approach. The results showed that compared with random sampling, adaptive sampling using CDFOS reduced the kriging estimation errors and misclassification rates, and thus would appear to be a better choice than random sampling, as additional sampling is required for delineating the 'contaminated' areas. - A sampling approach was derived for drawing additional samples while kriging

  18. Accuracy of total oxidant measurement as obtained by the phenolphthalin method

    Energy Technology Data Exchange (ETDEWEB)

    Louw, C W; Halliday, E C

    1963-01-01

    The phenolphthalin method of Haagen-Smit and Brunelle (1958) was chosen for a preliminary survey of total oxidant level in Pretoria air, because of its sensitivity. Difficulty, however, was encountered in obtaining reliable standard curves. Some improvement was obtained when conducting all operations except photometer measurements at the temperature of melting ice. It was also found that when the sequence of adding the reagents was changed, so as to simulate conditions during actual sampling, a standard curve approximating a straight line and differing considerably from that of McCabe (1953) was obtained. It follows that values of total oxidant obtained by any experimentor will depend to a certain extent upon the method of standard curve preparation he uses, and when comparisons are made between measurements by experimentors in different towns or countries this factor should be taken into consideration. The accuracy (95% confidence) obtained by the phenolphthalin method, using the mean of three successive samples, was shown to be in the region of 30% for very low amounts of oxidant.

  19. Parent-child agreement on the Behavior Rating Inventory of Executive Functioning (BRIEF) in a community sample of adolescents.

    Science.gov (United States)

    Egan, Kaitlyn N; Cohen, L Adelyn; Limbers, Christine

    2018-03-06

    Despite its widespread use, a minimal amount is known regarding the agreement between parent and youth ratings of youth's executive functioning on the Behavior Rating Inventory of Executive Functioning (BRIEF) in typically developing youth. The present study examined parent-child agreement on the BRIEF with a community sample of adolescents and their parents. Ninety-seven parent-child dyads (M age  = 13.91 years; SD = .52) completed the BRIEF self- and parent-report forms and a demographic questionnaire. Intraclass Correlation Coefficients (ICCs) and paired sample t-tests were used to evaluate agreement between self- and parent-reports on the BRIEF. Total sample ICCs indicated moderate to good parent-child agreement (0.46-0.68). Parents from the total sample reported significantly higher mean T-scores for their adolescents on Inhibit, Working Memory, Planning/Organization, Behavioral Regulation Index (BRI), Metacognition Index, and Global Executive Composite. Differences were found in regard to gender and race/ethnicity: ICCs were higher between parent-girl dyads on the scales that comprise the BRI than between parent-boy dyads. Parent-adolescent ICCs were also higher for adolescents who self-identified as White in comparison to those who identified as Non-White/Mixed Race on Emotional Control. These findings suggest gender and racial/ethnic differences should be considered when examining parent-child agreement on the BRIEF in typically developing adolescents.

  20. Thermoluminescence properties of zinc oxide obtained by solution combustion synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Orante B, V. R.; Escobar O, F. M.; Cruz V, C. [Universidad de Sonora, Departamento de Investigacion en Polimeros y Materiales, Apdo. Postal 130, 83000 Hermosillo, Sonora (Mexico); Bernal, R., E-mail: victor.orante@polimeros.uson.mx [Universidad de Sonora, Departamento de Investigacion en Fisica, Apdo. Postal 5-088, 83190 Hermosillo, Sonora (Mexico)

    2014-08-15

    High-dose thermoluminescence dosimetry properties of novel zinc oxide obtained by solution combustion synthesis in a glycine-nitrate process, with a non-stoichiometric value of the elemental stoichiometric coefficient (Φ{sub c}) are presented in this work. Zn O powder samples obtained were annealed afterwards at 900 grades C during 2 h in air. Sintered particles of sizes between ∼ 0.5 and ∼ 2 μm were obtained, according to scanning electron microscopy results. X-ray diffraction indicates the presence of the hexagonal phase of Zn O for the powder samples obtained, before and after thermal annealing, without any remaining nitrate peaks observed. Thermoluminescence glow curves of Zn O obtained after being exposed to beta radiation consists of two maxima; one located at ∼ 149 grades C and another at ∼ 308 grades C, being the latter the dosimetric component of the curve. Dosimetric characterization of non-stoichiometric zinc oxide provided experimental evidence like asymptotic behavior of the Tl signal fading for times greater than 16 h between irradiation and the corresponding Tl readout, as well as the linear behaviour of the dose response without saturation in the dose interval studied (from 12.5 up to 400 Gy). Such characteristics place Zn O phosphors obtained in this work as a promising material for high-dose radiation dosimetry applications (e.g., radiotherapy and food industry). (author)

  1. Thermoluminescence properties of zinc oxide obtained by solution combustion synthesis

    International Nuclear Information System (INIS)

    Orante B, V. R.; Escobar O, F. M.; Cruz V, C.; Bernal, R.

    2014-08-01

    High-dose thermoluminescence dosimetry properties of novel zinc oxide obtained by solution combustion synthesis in a glycine-nitrate process, with a non-stoichiometric value of the elemental stoichiometric coefficient (Φ c ) are presented in this work. Zn O powder samples obtained were annealed afterwards at 900 grades C during 2 h in air. Sintered particles of sizes between ∼ 0.5 and ∼ 2 μm were obtained, according to scanning electron microscopy results. X-ray diffraction indicates the presence of the hexagonal phase of Zn O for the powder samples obtained, before and after thermal annealing, without any remaining nitrate peaks observed. Thermoluminescence glow curves of Zn O obtained after being exposed to beta radiation consists of two maxima; one located at ∼ 149 grades C and another at ∼ 308 grades C, being the latter the dosimetric component of the curve. Dosimetric characterization of non-stoichiometric zinc oxide provided experimental evidence like asymptotic behavior of the Tl signal fading for times greater than 16 h between irradiation and the corresponding Tl readout, as well as the linear behaviour of the dose response without saturation in the dose interval studied (from 12.5 up to 400 Gy). Such characteristics place Zn O phosphors obtained in this work as a promising material for high-dose radiation dosimetry applications (e.g., radiotherapy and food industry). (author)

  2. Physicochemical and functional properties of protein isolate obtained from cottonseed meal.

    Science.gov (United States)

    Ma, Mengting; Ren, Yanjing; Xie, Wei; Zhou, Dayun; Tang, Shurong; Kuang, Meng; Wang, Yanqin; Du, Shuang-Kui

    2018-02-01

    To investigate the effect of preparation methods of cottonseed meals on protein properties, the physicochemical and functional properties of proteins isolated from hot-pressed solvent extraction cottonseed meal (HCM), cold-pressed solvent extraction cottonseed meal (CCM) and subcritical fluid extraction cottonseed meal (SCM) were investigated. Cottonseed proteins had two major bands (at about 45 and 50kD), two X-ray diffraction peaks (8.5° and 19.5°) and one endothermic peak (94.31°C-97.72°C). Proteins of HCM showed relatively more β-sheet (38.3%-40.5%), and less β-turn (22.2%-25.8%) and α-helix (15.8%-19.5%), indicating the presence of highly denatured protein molecules. Proteins of CCM and SCM exhibited high water/oil absorption capacity, emulsifying abilities, surface hydrophobicity and fluorescence intensity, suggesting that the proteins have potential as functional ingredients in the food industry. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Moon-Mars simulation campaign in volcanic Eifel: Remote science support and sample analysis

    Science.gov (United States)

    Offringa, Marloes; Foing, Bernard H.; Kamps, Oscar

    2016-07-01

    Moon-Mars analogue missions using a mock-up lander that is part of the ESA/ILEWG ExoGeoLab project were conducted during Eifel field campaigns in 2009, 2015 and 2016 (Foing et al., 2010). In the last EuroMoonMars2016 campaign the lander was used to conduct reconnaissance experiments and in situ geological scientific analysis of samples, with a payload that mainly consisted of a telescope and a UV-VIS reflectance spectrometer. The aim of the campaign was to exhibit possibilities for the ExoGeoLab lander to perform remotely controlled experiments and test its applicability in the field by simulating the interaction with astronauts. The Eifel region in Germany where the experiments with the ExoGeoLab lander were conducted is a Moon-Mars analogue due to its geological setting and volcanic rock composition. The research conducted by analysis equipment on the lander could function in support of Moon-Mars sample return missions, by providing preliminary insight into characteristics of the analyzed samples. The set-up of the prototype lander was that of a telescope with camera and solar power equipment deployed on the top, the UV-VIS reflectance spectrometer together with computers and a sample webcam were situated in the middle compartment and to the side a sample analysis test bench was attached, attainable by astronauts from outside the lander. An alternative light source that illuminated the samples in case of insufficient daylight was placed on top of the lander and functioned on solar power. The telescope, teleoperated from a nearby stationed pressurized transport vehicle that functioned as a base control center, attained an overview of the sampling area and assisted the astronauts in their initial scouting pursuits. Locations of suitable sampling sites based on these obtained images were communicated to the astronauts, before being acquired during a simulated EVA. Sampled rocks and soils were remotely analyzed by the base control center, while the astronauts

  4. All-atom simulation study of protein PTH(1-34) by using the Wang-Landau sampling method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung-Yeon [Korea National University of Transportation, Chungju (Korea, Republic of); Kwak, Woo-Seop [Chosun University, Gwangju (Korea, Republic of)

    2014-12-15

    We perform simulations of the N-terminal 34-residue protein fragment PTH(1-34), consisting of 581 atoms, of the 84-residue human parathyroid hormone by using the all-atom ECEPP/3 force field and the Wang-Landau sampling method. Through a massive high-performance computation, the density of states and the partition function Z(T), as a continuous function of T, are obtained for PTH(1-34). From the continuous partition function Z(T), the partition function zeros of PTH(1-34) are evaluated for the first time. From both the specific heat and the partition function zeros, two characteristic transition temperatures are obtained for the all-atom protein PTH(1-34). The higher transition temperature T{sub 1} and the lower transition temperature T{sub 2} of PTH(1-34) can be interpreted as the collapse temperature T{sub θ} and the folding temperature T{sub f} , respectively.

  5. A novel sol-gel-based amino-functionalized fiber for headspace solid-phase microextraction of phenol and chlorophenols from environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Bagheri, Habib [Department of Chemistry, Sharif University of Technology, P.O. Box 11365-9516, Tehran (Iran, Islamic Republic of)], E-mail: Bagheri@sharif.edu; Babanezhad, Esmaeil; Khalilian, Faezeh [Department of Chemistry, Sharif University of Technology, P.O. Box 11365-9516, Tehran (Iran, Islamic Republic of)

    2008-05-26

    A novel amino-functionalized polymer was synthesized using 3-(trimethoxysilyl) propyl amine (TMSPA) as precursor and hydroxy-terminated polydimethylsiloxane (OH-PDMS) by sol-gel technology and coated on fused-silica fiber. The synthesis was designed in a way to impart polar moiety into the coating network. The scanning electron microscopy (SEM) images of this new coating showed the homogeneity and the porous surface structure of the film. The efficiency of new coating was investigated for headspace solid-phase microextraction (SPME) of some environmentally important chlorophenols from aqueous samples followed by gas chromatography-mass spectrometry (GC-MS) analysis. Effect of different parameters influencing the extraction efficiency such as extraction temperature, extraction time, ionic strength and pH was investigated and optimized. In order to improve the separation efficiency of phenolic compounds on chromatography column all the analytes were derivatized prior to extraction using acetic anhydride at alkaline condition. The detection limits of the method under optimized conditions were in the range of 0.02-0.05 ng mL{sup -1}. The relative standard deviations (R.S.D.) (n = 6) at a concentration level of 0.5 ng mL{sup -1} were obtained between 6.8 and 10%. The calibration curves of chlorophenols showed linearity in the range of 0.5-200 ng mL{sup -1}. The proposed method was successfully applied to the extraction from spiked tap water samples and relative recoveries were higher than 90% for all the analytes.

  6. Automated high-resolution NMR with a sample changer

    International Nuclear Information System (INIS)

    Wade, C.G.; Johnson, R.D.; Philson, S.B.; Strouse, J.; McEnroe, F.J.

    1989-01-01

    Within the past two years, it has become possible to obtain high-resolution NMR spectra using automated commercial instrumentation. Software control of all spectrometer functions has reduced most of the tedious manual operations to typing a few computer commands or even making selections from a menu. Addition of an automatic sample changer is the next natural step in improving efficiency and sample throughput; it has a significant (and even unexpected) impact on how NMR laboratories are run and how it is taught. Such an instrument makes even sophisticated experiments routine, so that people with no previous exposure to NMR can run these experiments after a training session of an hour or less. This A/C Interface examines the impact of such instrumentation on both the academic and the industrial laboratory

  7. Influence of the sample anticoagulant on the measurements of impedance aggregometry in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Cristina Solomon

    2008-10-01

    Full Text Available Cristina Solomon1, Michael Winterhalter1, Isabel Gilde1, Ludwig Hoy2, Andreas Calatzis3, Niels Rahe-Meyer11Department of Anesthesiology, Hannover Medical School, Hannover, Germany; 2Institute for Biometry, Hannover Medical School, Hannover, Germany; 3Department Hemostasis Transfusion Medicine, University Hospital Munich, Munich, GermanyBackground: The standard method of assessment of platelet function is represented by light transmission aggregometry (LTA, performed in citrated platelet-rich plasma (PRP. With LTA, decrease and subsequent post-cardiopulmonary bypass (CPB recovery of platelet function have been reported during cardiac surgery. Multiple electrode aggregometry (MEA may be used as point-of-care method to monitor perioperative changes in platelet function. Since MEA assesses macroaggregation which is influenced by the plasmatic levels of unbound calcium, citrate may be inadequate as anticoagulant for MEA. We used citrate and heparin for MEA samples, to see with which anticoagulant the intraoperative decrease and postoperative recovery in platelet function previously described with other aggregometric methods in cardiac surgery may be observed with MEA.Methods: Blood was obtained from 60 patients undergoing routine cardiac surgery and the samples were collected in standard tubes containing unfractionated heparin (50 U/mL or trisodium citrate (3.2%. The samples were obtained before CPB, at 30 minutes on CPB, end of CPB and on the first postoperative day. MEA was performed using the Multiplate® analyzer. Collagen (COLtest, 100 μg/mL and TRAP-6 (thrombin receptor activating peptide, TRAPtest, 1mM/mL were used as aggregation agonists.Results: Platelet aggregometric response decreased significantly during CPB. Platelet aggregation assessed using TRAP-6 as agonist on heparinized blood significantly correlated with the duration of CPB (r = −0.41, p = 0.001, 2-tailed Pearson test. The aggregometric analysis performed on the first

  8. Communication: importance sampling including path correlation in semiclassical initial value representation calculations for time correlation functions.

    Science.gov (United States)

    Pan, Feng; Tao, Guohua

    2013-03-07

    Full semiclassical (SC) initial value representation (IVR) for time correlation functions involves a double phase space average over a set of two phase points, each of which evolves along a classical path. Conventionally, the two initial phase points are sampled independently for all degrees of freedom (DOF) in the Monte Carlo procedure. Here, we present an efficient importance sampling scheme by including the path correlation between the two initial phase points for the bath DOF, which greatly improves the performance of the SC-IVR calculations for large molecular systems. Satisfactory convergence in the study of quantum coherence in vibrational relaxation has been achieved for a benchmark system-bath model with up to 21 DOF.

  9. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    Science.gov (United States)

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Tank 241-AZ-101 and tank 241-AZ-102, airlift circulator operation vapor sampling and analysis plan

    International Nuclear Information System (INIS)

    TEMPLETON, A.M.

    1999-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of the tank 241-AZ-101 and 241-AZ-102 airlift circulators (ALCs). The purpose of the ALC operation is to support portions of the operational test procedure (OTP) for Project W-030 (OTP-W030-001) and to perform functional test in support of Project W-151. Project W-030 is the 241-A-702 ventilation upgrade project (241-AZ-702) and Project W-151 is the 241-AZ-101 Mixer Pump Test. The functional tests will check the operability of the tank 241-AZ-101 ALCs. Process Memo's No.2E98-082 and No.2E99-001 (LMHC 1999a, LMHC 1999b) direct the operation of the ALCs and the Industrial Hygiene monitoring respectively. A series of tests will be conducted in which the ALCs in tanks 241-AZ-101 and 241-AZ-102 will be operated at different air flow rates. Vapor samples will be obtained to determine constituents that may be present in the tank headspace during ALC operation at tanks 241-AZ-101 and 241-AZ-102 as the waste is disturbed. During the testing, vapor samples will be obtained from the headspace of tanks 241-AZ-101 and 241-AZ-102 via the unused port on the standard hydrogen monitoring system (SHMS). Results will be used to provide the waste feed delivery program with environmental air permitting data for tank waste disturbing activities. Because of radiological concerns, the samples will be filtered for particulates. It is recognized that this may remove some organic compounds

  11. Serial isoelectric focusing as an effective and economic way to obtain maximal resolution and high-throughput in 2D-based comparative proteomics of scarce samples: proof-of-principle.

    Science.gov (United States)

    Farhoud, Murtada H; Wessels, Hans J C T; Wevers, Ron A; van Engelen, Baziel G; van den Heuvel, Lambert P; Smeitink, Jan A

    2005-01-01

    In 2D-based comparative proteomics of scarce samples, such as limited patient material, established methods for prefractionation and subsequent use of different narrow range IPG strips to increase overall resolution are difficult to apply. Also, a high number of samples, a prerequisite for drawing meaningful conclusions when pathological and control samples are considered, will increase the associated amount of work almost exponentially. Here, we introduce a novel, effective, and economic method designed to obtain maximum 2D resolution while maintaining the high throughput necessary to perform large-scale comparative proteomics studies. The method is based on connecting different IPG strips serially head-to-tail so that a complete line of different IPG strips with sequential pH regions can be focused in the same experiment. We show that when 3 IPG strips (covering together the pH range of 3-11) are connected head-to-tail an optimal resolution is achieved along the whole pH range. Sample consumption, time required, and associated costs are reduced by almost 70%, and the workload is reduced significantly.

  12. Systematic sampling for suspended sediment

    Science.gov (United States)

    Robert B. Thomas

    1991-01-01

    Abstract - Because of high costs or complex logistics, scientific populations cannot be measured entirely and must be sampled. Accepted scientific practice holds that sample selection be based on statistical principles to assure objectivity when estimating totals and variances. Probability sampling--obtaining samples with known probabilities--is the only method that...

  13. Test sample handling apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    A test sample handling apparatus using automatic scintillation counting for gamma detection, for use in such fields as radioimmunoassay, is described. The apparatus automatically and continuously counts large numbers of samples rapidly and efficiently by the simultaneous counting of two samples. By means of sequential ordering of non-sequential counting data, it is possible to obtain precisely ordered data while utilizing sample carrier holders having a minimum length. (U.K.)

  14. Titania nanotube powders obtained by rapid breakdown anodization in perchloric acid electrolytes

    International Nuclear Information System (INIS)

    Ali, Saima; Hannula, Simo-Pekka

    2017-01-01

    Titania nanotube (TNT) powders are prepared by rapid break down anodization (RBA) in a 0.1 M perchloric acid (HClO 4 ) solution (Process 1), and ethylene glycol (EG) mixture with HClO 4 and water (Process 2). A study of the as-prepared and calcined TNT powders obtained by both processes is implemented to evaluate and compare the morphology, crystal structure, specific surface area, and the composition of the nanotubes. Longer TNTs are formed in Process 1, while comparatively larger pore diameter and wall thickness are obtained for the nanotubes prepared by Process 2. The TNTs obtained by Process 1 are converted to nanorods at 350 °C, while nanotubes obtained by Process 2 preserve tubular morphology till 350 °C. In addition, the TNTs prepared by an aqueous electrolyte have a crystalline structure, whereas the TNTs obtained by Process 2 are amorphous. Samples calcined till 450 °C have XRD peaks from the anatase phase, while the rutile phase appears at 550 °C for the TNTs prepared by both processes. The Raman spectra also show clear anatase peaks for all samples except the as-prepared sample obtained by Process 2, thus supporting the XRD findings. FTIR spectra reveal the presence of O-H groups in the structure for the TNTs obtained by both processes. However, the presence is less prominent for annealed samples. Additionally, TNTs obtained by Process 2 have a carbonaceous impurity present in the structure attributed to the electrolyte used in that process. While a negligible weight loss is typical for TNTs prepared from aqueous electrolytes, a weight loss of 38.6% in the temperature range of 25–600 °C is found for TNTs prepared in EG electrolyte (Process 2). A large specific surface area of 179.2 m 2 g −1 is obtained for TNTs prepared by Process 1, whereas Process 2 produces nanotubes with a lower specific surface area. The difference appears to correspond to the dimensions of the nanotubes obtained by the two processes. - Graphical abstract: Titania nanotube

  15. The cation inversion and magnetization in nanopowder zinc ferrite obtained by soft mechanochemical processing

    International Nuclear Information System (INIS)

    Milutinović, A.; Lazarević, Z.; Jovalekić, Č.; Kuryliszyn-Kudelska, I.; Romčević, M.; Kostić, S.; Romčević, N.

    2013-01-01

    Graphical abstract: - Highlights: • Nano powder of ZnFe 2 O 4 prepared by a soft mechanochemical route after 18 h milling. • Phase formation controlled by XRD, Raman spectroscopy and magnetic measurements. • Size, strain and cation inversion degree determined by Rietveld refinement. • We were able to estimate the degree of inversion at most 0.348 and 0.4. • Obtained extremely high values of saturation magnetizations at T = 4.5 K. - Abstract: Two zinc ferrite nanoparticle materials were prepared by the same method – soft mechanochemical synthesis, but starting from different powder mixtures: (1) Zn(OH) 2 /α-Fe 2 O 3 and (2) Zn(OH) 2 /Fe(OH) 3 . In both cases a single phase system was obtained after 18 h of milling. The progress of the synthesis was controlled by X-ray diffractometry (XRD), Raman spectroscopy, TEM and magnetic measurements. Analysis of the XRD patterns by Rietveld refinement allowed determination of the cation inversion degree for both obtained single phase ZnFe 2 O 4 samples. The sample obtained from mixture (1) has the cation inversion degree 0.3482 and the sample obtained from mixture (2) 0.400. Magnetization measurements were confirmed that the degrees of the inversion were well estimated. Comparison with published data shows that used method of synthesis gives nano powder samples with extremely high values of saturation magnetizations: sample (1) 78.3 emu g −1 and sample (2) 91.5 emu g −1 at T = 4.5 K

  16. Single session imaging of cerebellum at 7 Tesla: obtaining structure and function of multiple motor subsystems in individual subjects.

    Directory of Open Access Journals (Sweden)

    Melissa A Batson

    Full Text Available The recent increase in the use of high field MR systems is accompanied by a demand for acquisition techniques and coil systems that can take advantage of increased power and accuracy without being susceptible to increased noise. Physical location and anatomical complexity of targeted regions must be considered when attempting to image deeper structures with small nuclei and/or complex cytoarchitechtonics (i.e. small microvasculature and deep nuclei, such as the brainstem and the cerebellum (Cb. Once these obstacles are overcome, the concomitant increase in signal strength at higher field strength should allow for faster acquisition of MR images. Here we show that it is technically feasible to quickly and accurately detect blood oxygen level dependent (BOLD signal changes and obtain anatomical images of Cb at high spatial resolutions in individual subjects at 7 Tesla in a single one-hour session. Images were obtained using two high-density multi-element surface coils (32 channels in total placed beneath the head at the level of Cb, two channel transmission, and three-dimensional sensitivity encoded (3D, SENSE acquisitions to investigate sensorimotor activations in Cb. Two classic sensorimotor tasks were used to detect Cb activations. BOLD signal changes during motor activity resulted in concentrated clusters of activity within the Cb lobules associated with each task, observed consistently and independently in each subject: Oculomotor vermis (VI/VII and CrusI/II for pro- and anti-saccades; ipsilateral hemispheres IV-VI for finger tapping; and topographical separation of eye- and hand- activations in hemispheres VI and VIIb/VIII. Though fast temporal resolution was not attempted here, these functional patches of highly specific BOLD signal changes may reflect small-scale shunting of blood in the microvasculature of Cb. The observed improvements in acquisition time and signal detection are ideal for individualized investigations such as

  17. Generalized Probability Functions

    Directory of Open Access Journals (Sweden)

    Alexandre Souto Martinez

    2009-01-01

    Full Text Available From the integration of nonsymmetrical hyperboles, a one-parameter generalization of the logarithmic function is obtained. Inverting this function, one obtains the generalized exponential function. Motivated by the mathematical curiosity, we show that these generalized functions are suitable to generalize some probability density functions (pdfs. A very reliable rank distribution can be conveniently described by the generalized exponential function. Finally, we turn the attention to the generalization of one- and two-tail stretched exponential functions. We obtain, as particular cases, the generalized error function, the Zipf-Mandelbrot pdf, the generalized Gaussian and Laplace pdf. Their cumulative functions and moments were also obtained analytically.

  18. Mechanical and morphological properties of trabecular bone samples obtained from third metacarpal bones of cadavers of horses with a bone fragility syndrome and horses unaffected by that syndrome.

    Science.gov (United States)

    Symons, Jennifer E; Entwistle, Rachel C; Arens, Amanda M; Garcia, Tanya C; Christiansen, Blaine A; Fyhrie, David P; Stover, Susan M

    2012-11-01

    To determine morphological and mechanical properties of trabecular bone of horses with a bone fragility syndrome (BFS; including silicate-associated osteoporosis). Cylindrical trabecular bone samples from the distal aspects of cadaveric third metacarpal bones of 39 horses (19 horses with a BFS [BFS bone samples] and 20 horses without a BFS [control bone samples]). Bone samples were imaged via micro-CT for determination of bone volume fraction; apparent and mean mineralized bone densities; and trabecular number, thickness, and separation. Bone samples were compressed to failure for determination of apparent elastic modulus and stresses, strains, and strain energy densities for yield, ultimate, and failure loads. Effects of BFS and age of horses on variables were determined. BFS bone samples had 25% lower bone volume fraction, 28% lower apparent density, 18% lower trabecular number and thickness, and 16% greater trabecular separation versus control bone samples. The BFS bone samples had 22% lower apparent modulus and 32% to 33% lower stresses, 10% to 18% lower strains, and 41 % to 52% lower strain energy densities at yield, ultimate, and failure loads, compared with control bone samples. Differences between groups of bone samples were not detected for mean mineral density and trabecular anisotropy. Results suggested that horses with a BFS had osteopenia and compromised trabecular bone function, consistent with bone deformation and pathological fractures that develop in affected horses. Effects of this BFS may be systemic, and bones other than those that are clinically affected had changes in morphological and mechanical properties.

  19. A Fault Sample Simulation Approach for Virtual Testability Demonstration Test

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yong; QIU Jing; LIU Guanjun; YANG Peng

    2012-01-01

    Virtual testability demonstration test has many advantages,such as low cost,high efficiency,low risk and few restrictions.It brings new requirements to the fault sample generation.A fault sample simulation approach for virtual testability demonstration test based on stochastic process theory is proposed.First,the similarities and differences of fault sample generation between physical testability demonstration test and virtual testability demonstration test are discussed.Second,it is pointed out that the fault occurrence process subject to perfect repair is renewal process.Third,the interarrival time distribution function of the next fault event is given.Steps and flowcharts of fault sample generation are introduced.The number of faults and their occurrence time are obtained by statistical simulation.Finally,experiments are carried out on a stable tracking platform.Because a variety of types of life distributions and maintenance modes are considered and some assumptions are removed,the sample size and structure of fault sample simulation results are more similar to the actual results and more reasonable.The proposed method can effectively guide the fault injection in virtual testability demonstration test.

  20. Sampling in epidemiological research: issues, hazards and pitfalls

    Science.gov (United States)

    Tyrer, Stephen; Heyman, Bob

    2016-01-01

    Surveys of people's opinions are fraught with difficulties. It is easier to obtain information from those who respond to text messages or to emails than to attempt to obtain a representative sample. Samples of the population that are selected non-randomly in this way are termed convenience samples as they are easy to recruit. This introduces a sampling bias. Such non-probability samples have merit in many situations, but an epidemiological enquiry is of little value unless a random sample is obtained. If a sufficient number of those selected actually complete a survey, the results are likely to be representative of the population. This editorial describes probability and non-probability sampling methods and illustrates the difficulties and suggested solutions in performing accurate epidemiological research. PMID:27087985

  1. Characterization of functional SSR markers in Prosopis alba and their transferability across Prosopis species

    OpenAIRE

    María F. Pomponio; Cintia Acuña; Vivien Pentreath; Diego L. Lauenstein; Susana M. Poltri; Susana Torales

    2015-01-01

    Aim of study: The aim of the study was to characterize functional microsatellite markers in Prosopis alba and examine the transferability to species from the Prosopis genus. Area of the study: samples were obtained from natural populations of Argentina. Material and Methods: Eleven SSR functional markers related to stress and metabolism were amplified in a sample of 152 genotypes from P.alba, P. denudans, P. hassleriP. chilensis, P. flexuosa, and interspecific hybrids. Main res...

  2. Determination of Organophosphorous Pesticides in Environmental Water Samples Using Surface-Engineered C18 Functionalized Silica-Coated Core-Shell Magnetic Nanoparticles-Based Extraction Coupled with GC-MS/MS Analysis.

    Science.gov (United States)

    Srivastava, Neha; Kumari, Supriya; Nair, Kishore; Alam, Samsul; Raza, Syed K

    2017-05-01

    The present paper depicts a novel method based on magnetic SPE (MSPE) for the determination of organophosphorus pesticides (OPs) such as phorate, malathion, and chlorpyrifos in environmental water samples. In this study, C18 functionalized silica-coated core-shell iron oxide magnetic nanoparticles (MNPs) were used as a surface-engineered magnetic sorbent for the selective extraction of pesticides from aqueous samples, followed by GC-MS and GC-tandem MS analysis for confirmative determination of the analytes. Various important method parameters, including quantity of MNP adsorbent, volume of sample, effective time for extraction, nature of the desorbing solvent, and pH of the aqueous sample, were investigated and optimized to obtain maximum method performance. Under the optimized instrumental analysis conditions, good linearity (r2 value ≥0.994) was achieved at the concentration range of 0.5-500 μg/L. Recoveries were in the range of 79.2-96.3 and 80.4-97.5% in selective-ion monitoring and multiple reaction monitoring (MRM) modes, respectively, at the spiking concentrations of 1, 5, and 10 μg/L. MRM mode showed better sensitivity, selectivity, and low-level detection (0.5 μg/L) of analytes. The novel MSPE method is a simple, cheap, rapid, and eco-friendly method for the determination of OPs in environmental water samples.

  3. Research on the Sensorial Quality and Economic Efficiency in Obtaining of a certain Raw Meat Product - Mici Paste

    Directory of Open Access Journals (Sweden)

    Claudiu-Dan Salagean

    2013-11-01

    Full Text Available Research aimed the sensorial quality connected with the economic efficiency to obtain a certain raw meat product (mici paste in 4 experimental variants: 1 and 3 variants, with animal raw materials (meat + bacon and mix of natural spices - fine grinding variant (1 and coarse grinding variant (3 - chopping at the volf through the sieve of 3-4 mm; 2 and 4 variants, with animal raw materials (meat + bacon + vegetable protein supplements (textured soy protein + binder (protein + fiber + additive mix - fine grinding variant (2 and coarse grinding variant (4 - chopping at the volf through the sieve of 3 - 4 mm. In this respect organoleptic analyzes were performed on appearance (exterior and section, color, smell, texture and taste of the finished product (after roasting, the results highlighting that, in terms of organoleptic, sample 1 obtained the highest score (on a scale of 1-poor to 5-very good quality (average 21.83, followed by sample 3 (average 19.22, the very small difference in the case of sample 2 (average 19.19 and finally, sample 4 (average 18.75. It was noted that sample 1 obtained the highest score (average of all analyzed organoleptic indicators: appearance (4.33, color (4.39, smell (4.67, texture (4.33 and taste (4.11 being favorite by all volunteer subjects who participated at the analysis. The same thing was found in sensory analysis of mici paste in fresh/chilled condition: 65% of subjects preferred variant 1 followed by variant 3 (19.2%, variant 2 (11.5% and finally, variant 4 (3.8%. In terms of economic the highest efficiency was found in 2 (specific consumption 0.73 and 4 (specific consumption 0.77 variants compared to 1 (specific consumption 0.80 and 3 (specific consumption 0.82 variants, which translates into a reduction in the cost of products manufactured in the variants 2 and 4 (with protein supplements and additive mix by about 25-20% (with importance for the manufacturer. Also, thermal processing (roasting revealed the

  4. Soil sampling

    International Nuclear Information System (INIS)

    Fortunati, G.U.; Banfi, C.; Pasturenzi, M.

    1994-01-01

    This study attempts to survey the problems associated with techniques and strategies of soil sampling. Keeping in mind the well defined objectives of a sampling campaign, the aim was to highlight the most important aspect of representativeness of samples as a function of the available resources. Particular emphasis was given to the techniques and particularly to a description of the many types of samplers which are in use. The procedures and techniques employed during the investigations following the Seveso accident are described. (orig.)

  5. Estimating the residential demand function for natural gas in Seoul with correction for sample selection bias

    International Nuclear Information System (INIS)

    Yoo, Seung-Hoon; Lim, Hea-Jin; Kwak, Seung-Jun

    2009-01-01

    Over the last twenty years, the consumption of natural gas in Korea has increased dramatically. This increase has mainly resulted from the rise of consumption in the residential sector. The main objective of the study is to estimate households' demand function for natural gas by applying a sample selection model using data from a survey of households in Seoul. The results show that there exists a selection bias in the sample and that failure to correct for sample selection bias distorts the mean estimate, of the demand for natural gas, downward by 48.1%. In addition, according to the estimation results, the size of the house, the dummy variable for dwelling in an apartment, the dummy variable for having a bed in an inner room, and the household's income all have positive relationships with the demand for natural gas. On the other hand, the size of the family and the price of gas negatively contribute to the demand for natural gas. (author)

  6. Histopathological examination of nerve samples from pure neural leprosy patients: obtaining maximum information to improve diagnostic efficiency.

    Science.gov (United States)

    Antunes, Sérgio Luiz Gomes; Chimelli, Leila; Jardim, Márcia Rodrigues; Vital, Robson Teixeira; Nery, José Augusto da Costa; Corte-Real, Suzana; Hacker, Mariana Andréa Vilas Boas; Sarno, Euzenir Nunes

    2012-03-01

    Nerve biopsy examination is an important auxiliary procedure for diagnosing pure neural leprosy (PNL). When acid-fast bacilli (AFB) are not detected in the nerve sample, the value of other nonspecific histological alterations should be considered along with pertinent clinical, electroneuromyographical and laboratory data (the detection of Mycobacterium leprae DNA with polymerase chain reaction and the detection of serum anti-phenolic glycolipid 1 antibodies) to support a possible or probable PNL diagnosis. Three hundred forty nerve samples [144 from PNL patients and 196 from patients with non-leprosy peripheral neuropathies (NLN)] were examined. Both AFB-negative and AFB-positive PNL samples had more frequent histopathological alterations (epithelioid granulomas, mononuclear infiltrates, fibrosis, perineurial and subperineurial oedema and decreased numbers of myelinated fibres) than the NLN group. Multivariate analysis revealed that independently, mononuclear infiltrate and perineurial fibrosis were more common in the PNL group and were able to correctly classify AFB-negative PNL samples. These results indicate that even in the absence of AFB, these histopathological nerve alterations may justify a PNL diagnosis when observed in conjunction with pertinent clinical, epidemiological and laboratory data.

  7. Image re-sampling detection through a novel interpolation kernel.

    Science.gov (United States)

    Hilal, Alaa

    2018-06-01

    Image re-sampling involved in re-size and rotation transformations is an essential element block in a typical digital image alteration. Fortunately, traces left from such processes are detectable, proving that the image has gone a re-sampling transformation. Within this context, we present in this paper two original contributions. First, we propose a new re-sampling interpolation kernel. It depends on five independent parameters that controls its amplitude, angular frequency, standard deviation, and duration. Then, we demonstrate its capacity to imitate the same behavior of the most frequent interpolation kernels used in digital image re-sampling applications. Secondly, the proposed model is used to characterize and detect the correlation coefficients involved in re-sampling transformations. The involved process includes a minimization of an error function using the gradient method. The proposed method is assessed over a large database of 11,000 re-sampled images. Additionally, it is implemented within an algorithm in order to assess images that had undergone complex transformations. Obtained results demonstrate better performance and reduced processing time when compared to a reference method validating the suitability of the proposed approaches. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. The Relationship between Theory of Mind and Executive Function in a Sample of Children from Mainland China

    Science.gov (United States)

    Yang, Juan; Zhou, Shijie; Yao, Shuqiao; Su, Linyan; McWhinnie, Chad

    2009-01-01

    To explore the relationship between theory of mind (ToM) and executive function (EF) in a sample of individuals from mainland China, 20 children with autism spectrum disorders (ASD), 26 children with Attention Deficit Hyperactivity Disorder (ADHD), and 30 normal control subjects were compared on two batteries of ToM tasks and EF tasks. Children…

  9. Deconvolution of the density of states of tip and sample through constant-current tunneling spectroscopy

    Directory of Open Access Journals (Sweden)

    Holger Pfeifer

    2011-09-01

    Full Text Available We introduce a scheme to obtain the deconvolved density of states (DOS of the tip and sample, from scanning tunneling spectra determined in the constant-current mode (z–V spectroscopy. The scheme is based on the validity of the Wentzel–Kramers–Brillouin (WKB approximation and the trapezoidal approximation of the electron potential within the tunneling barrier. In a numerical treatment of z–V spectroscopy, we first analyze how the position and amplitude of characteristic DOS features change depending on parameters such as the energy position, width, barrier height, and the tip–sample separation. Then it is shown that the deconvolution scheme is capable of recovering the original DOS of tip and sample with an accuracy of better than 97% within the one-dimensional WKB approximation. Application of the deconvolution scheme to experimental data obtained on Nb(110 reveals a convergent behavior, providing separately the DOS of both sample and tip. In detail, however, there are systematic quantitative deviations between the DOS results based on z–V data and those based on I–V data. This points to an inconsistency between the assumed and the actual transmission probability function. Indeed, the experimentally determined differential barrier height still clearly deviates from that derived from the deconvolved DOS. Thus, the present progress in developing a reliable deconvolution scheme shifts the focus towards how to access the actual transmission probability function.

  10. Composite scaffolds for osteochondral repair obtained by combination of additive manufacturing, leaching processes and hMSC-CM functionalization.

    Science.gov (United States)

    Díaz Lantada, Andrés; Alarcón Iniesta, Hernán; García-Ruíz, Josefa Predestinación

    2016-02-01

    Articular repair is a relevant and challenging area for the emerging fields of tissue engineering and biofabrication. The need of significant gradients of properties, for the promotion of osteochondral repair, has led to the development of several families of composite biomaterials and scaffolds, using different effective approaches, although a perfect solution has not yet been found. In this study we present the design, modeling, rapid manufacturing and in vitro testing of a composite scaffold aimed at osteochondral repair. The presented composite scaffold stands out for having a functional gradient of density and stiffness in the bony phase, obtained in titanium by means of computer-aided design combined with additive manufacture using selective laser sintering. The chondral phase is obtained by sugar leaching, using a PDMS matrix and sugar as porogen, and is joined to the bony phase during the polymerization of PDMS, therefore avoiding the use of supporting adhesives or additional intermediate layers. The mechanical performance of the construct is biomimetic and the stiffness values of the bony and chondral phases can be tuned to the desired applications, by means of controlled modifications of different parameters. A human mesenchymal stem cell (h-MSC) conditioned medium (CM) is used for improving scaffold response. Cell culture results provide relevant information regarding the viability of the composite scaffolds used. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Functional magnetic resonance maps obtained by personal computer; Mapas de resonancia magnetica funcional obtenidos con PC

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, F. j.; Manjon, J. V.; Robles, M. [Universidad Politecnica de Valencia (Spain); Marti-Bonmati, L.; Dosda, R. [Cinica Quiron. Valencia (Spain); Molla, E. [Universidad de Valencia (Spain)

    2001-07-01

    Functional magnetic resonance (fMR) is of special relevance in the analysis of certain types of brain activation. The present report describes the development of a simple software program for use with personal computers (PCs) that analyzes these images and provides functional activation maps. Activation maps are based on the temporal differences in oxyhemoglobin in tomographic images. To detect these differences, intensities registered repeatedly during brain control and activation are compared. The experiments were performed with a 1.5-Tesla MR unit. To verify the reliability of the program fMR studies were carried out in 4 healthy individuals (12 contiguous slices, 80 images per slice every 3.1 seconds for a total of 960 images). All the images were transferred to a PC and were processed pixel by pixel within each sequence to obtain an intensity/time curve. The statistical study of the results (Student's test and cross correlation analysis) made it possible to establish the activation of each pixel. The images were prepared using spatial filtering, temporal filtering, baseline correction, normalization and segmentation of the parenchyma. The postprocessing of the results involved the elimination of single pixels, superposition of an anatomical image of greater spatial resolution and anti-aliasing. The application (Xfun 1.0, Valencia, Spain) was developed in Microsoft Visual C++5.0 Developer Studio for Windows NT Workstation. As a representative example, the program took 8.2 seconds to calculate and present the results of the entire study (12 functional maps). In the motor and visual activation experiments, the activation corresponding to regions proximal to the central sulcus of the hemisphere contralateral to the hand that moved and in the occipital cortex were observed. While programs that calculate activation maps are available, the development of software for PCs running Microsoft Windows ensures several key features for its use on a daily basis: it is

  12. RNAdualPF: software to compute the dual partition function with sample applications in molecular evolution theory.

    Science.gov (United States)

    Garcia-Martin, Juan Antonio; Bayegan, Amir H; Dotu, Ivan; Clote, Peter

    2016-10-19

    RNA inverse folding is the problem of finding one or more sequences that fold into a user-specified target structure s 0 , i.e. whose minimum free energy secondary structure is identical to the target s 0 . Here we consider the ensemble of all RNA sequences that have low free energy with respect to a given target s 0 . We introduce the program RNAdualPF, which computes the dual partition function Z ∗ , defined as the sum of Boltzmann factors exp(-E(a,s 0 )/RT) of all RNA nucleotide sequences a compatible with target structure s 0 . Using RNAdualPF, we efficiently sample RNA sequences that approximately fold into s 0 , where additionally the user can specify IUPAC sequence constraints at certain positions, and whether to include dangles (energy terms for stacked, single-stranded nucleotides). Moreover, since we also compute the dual partition function Z ∗ (k) over all sequences having GC-content k, the user can require that all sampled sequences have a precise, specified GC-content. Using Z ∗ , we compute the dual expected energy 〈E ∗ 〉, and use it to show that natural RNAs from the Rfam 12.0 database have higher minimum free energy than expected, thus suggesting that functional RNAs are under evolutionary pressure to be only marginally thermodynamically stable. We show that C. elegans precursor microRNA (pre-miRNA) is significantly non-robust with respect to mutations, by comparing the robustness of each wild type pre-miRNA sequence with 2000 [resp. 500] sequences of the same GC-content generated by RNAdualPF, which approximately [resp. exactly] fold into the wild type target structure. We confirm and strengthen earlier findings that precursor microRNAs and bacterial small noncoding RNAs display plasticity, a measure of structural diversity. We describe RNAdualPF, which rapidly computes the dual partition function Z ∗ and samples sequences having low energy with respect to a target structure, allowing sequence constraints and specified GC

  13. Van der Waals potentials between metal clusters and helium atoms obtained with density functional theory and linear response methods

    International Nuclear Information System (INIS)

    Liebrecht, M.

    2014-01-01

    The importance of van der Waals interactions in many diverse research fields such as, e. g., polymer science, nano--materials, structural biology, surface science and condensed matter physics created a high demand for efficient and accurate methods that can describe van der Waals interactions from first principles. These methods should be able to deal with large and complex systems to predict functions and properties of materials that are technologically and biologically relevant. Van der Waals interactions arise due to quantum mechanical correlation effects and finding appropriate models an numerical techniques to describe this type of interaction is still an ongoing challenge in electronic structure and condensed matter theory. This thesis introduces a new variational approach to obtain intermolecular interaction potentials between clusters and helium atoms by means of density functional theory and linear response methods. It scales almost linearly with the number of electrons and can therefore be applied to much larger systems than standard quantum chemistry techniques. The main focus of this work is the development of an ab-initio method to account for London dispersion forces, which are purely attractive and dominate the interaction of non--polar atoms and molecules at large distances. (author) [de

  14. Histopathological examination of nerve samples from pure neural leprosy patients: obtaining maximum information to improve diagnostic efficiency

    Directory of Open Access Journals (Sweden)

    Sérgio Luiz Gomes Antunes

    2012-03-01

    Full Text Available Nerve biopsy examination is an important auxiliary procedure for diagnosing pure neural leprosy (PNL. When acid-fast bacilli (AFB are not detected in the nerve sample, the value of other nonspecific histological alterations should be considered along with pertinent clinical, electroneuromyographical and laboratory data (the detection of Mycobacterium leprae DNA with polymerase chain reaction and the detection of serum anti-phenolic glycolipid 1 antibodies to support a possible or probable PNL diagnosis. Three hundred forty nerve samples [144 from PNL patients and 196 from patients with non-leprosy peripheral neuropathies (NLN] were examined. Both AFB-negative and AFB-positive PNL samples had more frequent histopathological alterations (epithelioid granulomas, mononuclear infiltrates, fibrosis, perineurial and subperineurial oedema and decreased numbers of myelinated fibres than the NLN group. Multivariate analysis revealed that independently, mononuclear infiltrate and perineurial fibrosis were more common in the PNL group and were able to correctly classify AFB-negative PNL samples. These results indicate that even in the absence of AFB, these histopathological nerve alterations may justify a PNL diagnosis when observed in conjunction with pertinent clinical, epidemiological and laboratory data.

  15. Sample preparation and analysis of large 238PuO2 and ThO2 spheres

    International Nuclear Information System (INIS)

    Wise, R.L.; Selle, J.E.

    1975-01-01

    A program was initiated to determine the density gradient across a large spherical 238 PuO 2 sample produced by vacuum hot pressing. Due to the high thermal output of the ceramic a thin section was necessary to prevent overheating of the plastic mount. Techniques were developed for cross sectioning, mounting, grinding, and polishing of the sample. The polished samples were then analyzed on a quantitative image analyzer to determine the density as a function of location across the sphere. The techniques for indexing, analyzing, and reducing the data are described. Typical results obtained on a ThO 2 simulant sphere are given

  16. Veterinary antibiotic resistance, residues, and ecological risks in environmental samples obtained from poultry farms, Egypt.

    Science.gov (United States)

    Dahshan, Hesham; Abd-Elall, Amr Mohamed Mohamed; Megahed, Ayman Mohamed; Abd-El-Kader, Mahdy A; Nabawy, Ehab Elsayed

    2015-02-01

    In Egypt, poultry production constitutes one of the main sources of pollution with veterinary antibiotics (VAs) into the environment. About 80 % of meat production in Egypt is of poultry origin, and the potential environmental risks associated with the use of VAs in these farms have not yet been properly evaluated. Thus, the main purpose of this research was to evaluate the prevalence of antibiotic-resistant enteric key bacteria and the incidence of residual antibiotics in poultry farm environmental samples and to determine whether fertilizing soils with poultry litter from farms potentially brings ecological risks. From December 2011 to September 2012, a total of 225 litter, bird dropping, and water samples were collected from 75 randomly selected boiler poultry farms. A high prevalence of Escherichia coli (n = 179; 79.5 %) in contrast to the low prevalence of Salmonella spp. (n = 7; 3.1 %) was detected. Amongst E. coli isolates, serotypes O142:K86, O125:K70, O91:K, and O119:K69 were the most common. Meanwhile, Salmonella enterica serotypes emek and enteritidis were recovered. The antibiograms using the disc diffusion method revealed significantly more common resistant and multi-resistant isolates in broiler poultry farms. Residues of tetracycline and ciprofloxacin were detected at 2.125 and 1.401 mg kg(-1) mean levels, respectively, in environmental samples contaminated with E. coli-resistant strains by HPLC. The risk evaluations highlighted that tetracycline residues in poultry litter significantly display environmental risks with a hazard quotient value above 1 (1.64). Our study implies that ineffective implementation of veterinary laws which guide and guard against incorrect VA usage may potentially bring health and environmental risks.

  17. 29 CFR 1403.3 - Obtaining data on labor-management disputes.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Obtaining data on labor-management disputes. 1403.3 Section... FUNCTIONS AND DUTIES § 1403.3 Obtaining data on labor-management disputes. When the existence of a labor-management dispute comes to the attention of the Federal Service upon a request for mediation service from...

  18. Quantifying regional cerebral blood flow with N-isopropyl-p-[123I]iodoamphetamine and SPECT by one-point sampling method

    International Nuclear Information System (INIS)

    Odano, Ikuo; Takahashi, Naoya; Noguchi, Eikichi; Ohtaki, Hiro; Hatano, Masayoshi; Yamazaki, Yoshihiro; Higuchi, Takeshi; Ohkubo, Masaki.

    1994-01-01

    We developed a new non-invasive technique; one-point sampling method, for quantitative measurement of regional cerebral blood flow (rCBF) with N-isopropyl-p-[ 123 I]iodoamphetamine and SPECT. Although the continuous withdrawal of arterial blood and octanol treatment of the blood are required in the conventional microsphere method, the new technique dose not require these two procedures. The total activity of 123 I-IMP obtained by the continuous withdrawal of arterial blood is inferred by the activity of 133 I-IMP obtained by the one point arterial sample using a regression line. To determine when one point sampling time was optimum for inferring integral input function of the continuous withdrawal and whether the treatment of sampled blood for octanol fraction was required, we examined a correlation between the total activity of arterial blood withdrawn from 0 to 5 min after the injection and the activity of one point sample obtained at time t, and calculated a regression line. As a result, the minimum % error for the inference using the regression line was obtained at 6 min after the 123 I-IMP injection, moreover, the octanol treatment was not required. Then examining an effect on the values of rCBF when the sampling time was deviated from 6 min, we could correct the values in approximately 3% error when the sample was obtained at 6±1 min after the injection. The one-point sampling method provides accurate and relatively non-invasive measurement of rCBF without octanol extraction of arterial blood. (author)

  19. Inverse electronic scattering by Green's functions and singular values decomposition

    International Nuclear Information System (INIS)

    Mayer, A.; Vigneron, J.-P.

    2000-01-01

    An inverse scattering technique is developed to enable a sample reconstruction from the diffraction figures obtained by electronic projection microscopy. In its Green's functions formulation, this technique takes account of all orders of diffraction by performing an iterative reconstruction of the wave function on the observation screen. This scattered wave function is then backpropagated to the sample to determine the potential-energy distribution, which is assumed real valued. The method relies on the use of singular values decomposition techniques, thus providing the best least-squares solutions and enabling a reduction of noise. The technique is applied to the analysis of a two-dimensional nanometric sample that is observed in Fresnel conditions with an electronic energy of 25 eV. The algorithm turns out to provide results with a mean relative error of the order of 5% and to be very stable against random noise

  20. Sampling device for withdrawing a representative sample from single and multi-phase flows

    Science.gov (United States)

    Apley, Walter J.; Cliff, William C.; Creer, James M.

    1984-01-01

    A fluid stream sampling device has been developed for the purpose of obtaining a representative sample from a single or multi-phase fluid flow. This objective is carried out by means of a probe which may be inserted into the fluid stream. Individual samples are withdrawn from the fluid flow by sampling ports with particular spacings, and the sampling parts are coupled to various analytical systems for characterization of the physical, thermal, and chemical properties of the fluid flow as a whole and also individually.

  1. Sample selection based on kernel-subclustering for the signal reconstruction of multifunctional sensors

    International Nuclear Information System (INIS)

    Wang, Xin; Wei, Guo; Sun, Jinwei

    2013-01-01

    The signal reconstruction methods based on inverse modeling for the signal reconstruction of multifunctional sensors have been widely studied in recent years. To improve the accuracy, the reconstruction methods have become more and more complicated because of the increase in the model parameters and sample points. However, there is another factor that affects the reconstruction accuracy, the position of the sample points, which has not been studied. A reasonable selection of the sample points could improve the signal reconstruction quality in at least two ways: improved accuracy with the same number of sample points or the same accuracy obtained with a smaller number of sample points. Both ways are valuable for improving the accuracy and decreasing the workload, especially for large batches of multifunctional sensors. In this paper, we propose a sample selection method based on kernel-subclustering distill groupings of the sample data and produce the representation of the data set for inverse modeling. The method calculates the distance between two data points based on the kernel-induced distance instead of the conventional distance. The kernel function is a generalization of the distance metric by mapping the data that are non-separable in the original space into homogeneous groups in the high-dimensional space. The method obtained the best results compared with the other three methods in the simulation. (paper)

  2. Plasma as alternatively sample to quantify tetanus antitoxin

    Directory of Open Access Journals (Sweden)

    Ariel Menéndez-Barrios

    2015-08-01

    Full Text Available Tetanus antitoxin is quantified in Cuba at blood banks, from the serum of immunized donors, to produce aspecific human gamma globulin. A heterogeneous indirect immunoenzymatic assay is used, using the serum as analytical sample. The possible use of plasma obtained from plasmapheresis as alternative sample was evaluated in this research, to minimize the volume of total blood extracted to the donors. One hundred plasma donors who came to donate between October and November 2013 were selected by simple random sampling. Serum sample was obtained for extraction of 5 mL of blood, deposited in dry glass tube. While the other sample took 1.5 mL of plasma in a plastic tube with cover, at the end of the donation directly of the unit of plasma collected. Comparison of the difference between the means of both groups was done using SPSS for Windows. It was found that the values obtained in serum were bigger than those obtained in plasma. Difference between the means of both groups was statistically significant (p 0.00. It is not advisable to use the obtained plasma of the plasmapheresis as analytic sample in this assay.

  3. IRAS bright galaxy sample. II. The sample and luminosity function

    International Nuclear Information System (INIS)

    Soifer, B.T.; Sanders, D.B.; Neugebauer, G.; Madore, B.F.; Danielson, G.E.; David Dunlap Observatory, Richmond Hill, Canada; Palomar Observatory; California Institute of Technology, Pasadena)

    1987-01-01

    A statistically complete sample of 324 of the brightest infrared galaxies discovered at 60 microns in the IRAS all-sky survey is described. The results show that far-infrared emission is a significant luminosity component in the local universe, representing 25 percent of the luminosity emitted by stars in the same volume. Above 10 to the 11th solar luminosities, the infrared luminous galaxies are the dominant population of objects in the universe, being as numerous as the Seyfert galaxies and more numerous than quasars at higher luminosities. The infrared luminosity appears to be independent of the optical luminosity of galaxies. Most infrared bright galaxies appear to require much of the interstellar matter to be contributing to the observed infrared luminosity. Approximately 60-80 percent of the far-infrared luminosity of the local universe can be attributed, directly or indirectly, to recent or ongoing star formation. 67 references

  4. Calibration samples for accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Hershberger, R.L.; Flynn, D.S.; Gabbard, F.

    1981-01-01

    Radioactive samples with precisely known numbers of atoms are useful as calibration sources for lifetime measurements using accelerator mass spectrometry. Such samples can be obtained in two ways: either by measuring the production rate as the sample is created or by measuring the decay rate after the sample has been obtained. The latter method requires that a large sample be produced and that the decay constant be accurately known. The former method is a useful and independent alternative, especially when the decay constant is not well known. The facilities at the University of Kentucky for precision measurements of total neutron production cross sections offer a source of such calibration samples. The possibilities, while quite extensive, would be limited to the proton rich side of the line of stability because of the use of (p,n) and (α,n) reactions for sample production

  5. [Transciptome among Mexicans: a large scale methodology to analyze the genetics expression profile of simultaneous samples in muscle, adipose tissue and lymphocytes obtained from the same individual].

    Science.gov (United States)

    Bastarrachea, Raúl A; López-Alvarenga, Juan Carlos; Kent, Jack W; Laviada-Molina, Hugo A; Cerda-Flores, Ricardo M; Calderón-Garcidueñas, Ana Laura; Torres-Salazar, Amada; Torres-Salazar, Amanda; Nava-González, Edna J; Solis-Pérez, Elizabeth; Gallegos-Cabrales, Esther C; Cole, Shelley A; Comuzzie, Anthony G

    2008-01-01

    We describe the methodology used to analyze multiple transcripts using microarray techniques in simultaneous biopsies of muscle, adipose tissue and lymphocytes obtained from the same individual as part of the standard protocol of the Genetics of Metabolic Diseases in Mexico: GEMM Family Study. We recruited 4 healthy male subjects with BM1 20-41, who signed an informed consent letter. Subjects participated in a clinical examination that included anthropometric and body composition measurements, muscle biopsies (vastus lateralis) subcutaneous fat biopsies anda blood draw. All samples provided sufficient amplified RNA for microarray analysis. Total RNA was extracted from the biopsy samples and amplified for analysis. Of the 48,687 transcript targets queried, 39.4% were detectable in a least one of the studied tissues. Leptin was not detectable in lymphocytes, weakly expressed in muscle, but overexpressed and highly correlated with BMI in subcutaneous fat. Another example was GLUT4, which was detectable only in muscle and not correlated with BMI. Expression level concordance was 0.7 (p< 0.001) for the three tissues studied. We demonstrated the feasibility of carrying out simultaneous analysis of gene expression in multiple tissues, concordance of genetic expression in different tissues, and obtained confidence that this method corroborates the expected biological relationships among LEPand GLUT4. TheGEMM study will provide a broad and valuable overview on metabolic diseases, including obesity and type 2 diabetes.

  6. Monitoring of trace amounts of heavy metals in different food and water samples by flame atomic absorption spectrophotometer after preconcentration by amine-functionalized graphene nanosheet.

    Science.gov (United States)

    Behbahani, Mohammad; Tapeh, Nasim Akbari Ghareh; Mahyari, Mojtaba; Pourali, Ali Reza; Amin, Bahareh Golrokh; Shaabani, Ahmad

    2014-11-01

    We are introducing graphene oxide modified with amine groups as a new solid phase for extraction of heavy metal ions including cadmium(II), copper(II), nickel(II), zinc(II), and lead(II). Effects of pH value, flow rates, type, concentration, and volume of the eluent, breakthrough volume, and the effect of potentially interfering ions were studied. Under optimized conditions, the extraction efficiency is >97 %, the limit of detections are 0.03, 0.05, 0.2, 0.1, and 1 μg L(-1) for the ions of cadmium, copper, nickel, zinc, and lead, respectively, and the adsorption capacities for these ions are 178, 142, 110, 125, and 210 mg g(-1). The amino-functionalized graphene oxide was characterized by thermogravimetric analysis, transmission electron microscopy, scanning electron microscopy, and Fourier transform infrared spectrometry. The proposed method was successfully applied in the analysis of environmental water and food samples. Good spiked recoveries over the range of 95.8-100.0 % were obtained. This work not only proposes a useful method for sample preconcentration but also reveals the great potential of modified graphene as an excellent sorbent material in analytical processes.

  7. The influence of n-butyl mercaptan on acrylic compounds obtained winder γ-gamma radiation

    International Nuclear Information System (INIS)

    Ribeiro, Marcos S.; Parra, Duclerc F.; Lugao, Ademar B.

    2013-01-01

    The chain transfer agents play a key role in the production of polymers, as they allow better control of their molecular weight, among other functions. For this reason we performed this study to perform an analysis on the influence of n-butyl mercaptan in the reaction of compounds of ethyl methacrylate by varying the density and shrinkage of the samples. In the present study can be seen that n-butyl mercaptan, acts as transfer agent, which influences the reaction kinetics of composite acrylic, since it presence in the compound increased average density and contraction average. It is also possible to minimize the variability of the compound density, even if they are altered. Final products with improved properties homogeneously could be obtained. (author)

  8. Chain sampling plan (ChSP-1) for desired acceptable quality level (AQL) and limiting quality level (LQL)

    Science.gov (United States)

    Raju, C.; Vidya, R.

    2017-11-01

    Chain Sampling Plan is widely used whenever a small sample attributes plan is required to be used for situations involving destructive products coming out of continuous production process [1, 2]. This paper presents a procedure for the construction and selection of a ChSP-1 by attributes inspection based on membership functions [3]. A procedure using search technique is developed for obtaining the parameters of single sampling plan for a given set of AQL and LQL values. A sample of tables providing ChSP-1 plans for various combinations of AQL and LQL values are presented [4].

  9. Titania nanotube powders obtained by rapid breakdown anodization in perchloric acid electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Saima, E-mail: saima.ali@aalto.fi; Hannula, Simo-Pekka

    2017-05-15

    Titania nanotube (TNT) powders are prepared by rapid break down anodization (RBA) in a 0.1 M perchloric acid (HClO{sub 4}) solution (Process 1), and ethylene glycol (EG) mixture with HClO{sub 4} and water (Process 2). A study of the as-prepared and calcined TNT powders obtained by both processes is implemented to evaluate and compare the morphology, crystal structure, specific surface area, and the composition of the nanotubes. Longer TNTs are formed in Process 1, while comparatively larger pore diameter and wall thickness are obtained for the nanotubes prepared by Process 2. The TNTs obtained by Process 1 are converted to nanorods at 350 °C, while nanotubes obtained by Process 2 preserve tubular morphology till 350 °C. In addition, the TNTs prepared by an aqueous electrolyte have a crystalline structure, whereas the TNTs obtained by Process 2 are amorphous. Samples calcined till 450 °C have XRD peaks from the anatase phase, while the rutile phase appears at 550 °C for the TNTs prepared by both processes. The Raman spectra also show clear anatase peaks for all samples except the as-prepared sample obtained by Process 2, thus supporting the XRD findings. FTIR spectra reveal the presence of O-H groups in the structure for the TNTs obtained by both processes. However, the presence is less prominent for annealed samples. Additionally, TNTs obtained by Process 2 have a carbonaceous impurity present in the structure attributed to the electrolyte used in that process. While a negligible weight loss is typical for TNTs prepared from aqueous electrolytes, a weight loss of 38.6% in the temperature range of 25–600 °C is found for TNTs prepared in EG electrolyte (Process 2). A large specific surface area of 179.2 m{sup 2} g{sup −1} is obtained for TNTs prepared by Process 1, whereas Process 2 produces nanotubes with a lower specific surface area. The difference appears to correspond to the dimensions of the nanotubes obtained by the two processes. - Graphical abstract

  10. Sample and plume luminescence in fast heavy ion induced desorption

    International Nuclear Information System (INIS)

    Tuszynski, W.; Koch, K.; Hilf, E.R.

    1996-01-01

    The luminescence arising in 252 Cf-fission fragment induced desorption events has been measured using the time-correlated single photon counting technique. Photons emitted from the sample have been guided from a plasma desorption ion source to a photodetector by an optical fibre. Spectra and decay functions have been obtained using thin layers of Coronene or POPOP as samples. The results are strongly dependent on the acceleration field applied for ion extraction. Approximately 10 photons per fission fragment have been produced when applying no accelerating voltage. The results clearly show that these photons come from radiative electronic relaxations of molecules in the solid sample. Considerably more photons per fission fragment have been produced when applying a positive acceleration voltage. The intensity increases almost linearly for acceleration fields below 10 kV/cm and saturates at a nearly 10-fold higher value when compared to no acceleration. The intensity is also affected by the homogeneity of the accelerating field. These additional photons are attributed to radiative electronic relaxations of desorbed neutral molecules in the plume excited by inelastic collisions with accelerated positive ions. No additional photons have been observed when extracting negative ions. The negative ions produced do obviously not hit and/or excite desorbed neutral molecules, presumably due to their specific desorption characteristics. The experimental data have been analyzed by comparing with the cw and time-resolved sample luminescence obtained by optical excitation. The findings demonstrate that valuable information on ion-solid interactions, on specific desorption quantities and on processes in the plume can be obtained by measuring and analyzing the luminescence induced by the impact of high energy primary ions. (orig.)

  11. Random Walks on Directed Networks: Inference and Respondent-Driven Sampling

    Directory of Open Access Journals (Sweden)

    Malmros Jens

    2016-06-01

    Full Text Available Respondent-driven sampling (RDS is often used to estimate population properties (e.g., sexual risk behavior in hard-to-reach populations. In RDS, already sampled individuals recruit population members to the sample from their social contacts in an efficient snowball-like sampling procedure. By assuming a Markov model for the recruitment of individuals, asymptotically unbiased estimates of population characteristics can be obtained. Current RDS estimation methodology assumes that the social network is undirected, that is, all edges are reciprocal. However, empirical social networks in general also include a substantial number of nonreciprocal edges. In this article, we develop an estimation method for RDS in populations connected by social networks that include reciprocal and nonreciprocal edges. We derive estimators of the selection probabilities of individuals as a function of the number of outgoing edges of sampled individuals. The proposed estimators are evaluated on artificial and empirical networks and are shown to generally perform better than existing estimators. This is the case in particular when the fraction of directed edges in the network is large.

  12. Evaluation of bi-functionalized mesoporous silicas as reversed phase/cation-exchange mixed-mode sorbents for multi-residue solid phase extraction of veterinary drug residues in meat samples.

    Science.gov (United States)

    Casado, Natalia; Pérez-Quintanilla, Damián; Morante-Zarcero, Sonia; Sierra, Isabel

    2017-04-01

    A SBA-15 type mesoporous silica was synthesized and bi-functionalized with octadecylsilane (C18) or octylsilane (C8), and sulfonic acid (SO 3 - ) groups in order to obtain materials with reversed-phase/strong cation-exchange mixed-mode retention mechanism. The resulting hybrid materials (SBA-15-C18-SO 3 - and SBA-15-C8-SO 3 - ) were comprehensively characterized. They showed high surface area, high pore volume and controlled porous size. Elemental analysis of the materials revealed differences in the amount of C18 and C8. SBA-15-C18-SO 3 - contained 0.19mmol/g of C18, while SBA-15-C8-SO 3 - presented 0.54mmol/g of C8. The SO 3 - groups anchored to the silica surface of the pore walls were 0.20 and 0.09mmol/g, respectively. The bi-functionalized materials were evaluated as SPE sorbents for the multi-residue extraction of 26 veterinary drug residues in meat samples using ultra-high-performance liquid chromatography coupled to mass spectrometry detector (UHPLC-MS/MS). Different sorbent amounts (100 and 200mg) and organic solvents were tested to optimize the extraction procedure. Both silicas showed big extraction potential and were successful in the extraction of the target analytes. The mixed-mode retention mechanism was confirmed by comparing both silicas with SBA-15 mesoporous silica mono-functionalized with C18 and C8. Best results were achieved with 200mg of SBA-15-C18-SO 3 - obtaining recoveries higher than 70% for the majority of analytes. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Microstructural characteristics of low-temperature (1400°C sintered MgO obtained from seawater

    Directory of Open Access Journals (Sweden)

    Jakić Jelena

    2017-01-01

    Full Text Available The purpose of this study was to investigate the influence of a rinsing of Mg(OH2 precipitated from seawater by substoichiometric precipitation (80% precipitation and the addition of TiO2 on microstructural characteristics of the MgO obtained by sintering at low temperature (1400°C. The results of examination indicate that the method of rinsing of the magnesium hydroxide precipitate in the technological process of obtaining MgO from seawater significantly affects the chemical composition of samples, primarily with regard to the CaO and B2O3 content. The samples were doped with TiO2 to improve the evaporation of B2O3 and sintering of MgO samples that were characterized by XRD and SEM/EDS. These techniques confirmed the high purity of MgO samples obtained and the formation of secondary compounds in very small quantities that have a positive effect on the densification.

  14. Direct separation of plutonium by thermochromatography from environmental samples

    International Nuclear Information System (INIS)

    Wacker, L.; Kraehenbuehl, U.

    2002-01-01

    A thermochromatographic separation was performed on plutonium from environmental soil samples. This procedure was investigated with the goal to measure low concentrations of plutonium by inductively coupled plasma-mass spectrometry (ICP-MS). The soil sample was chlorinated by thionylchloride as reactive gas at a temperature of 1400 K. The volatile chlorides were separated chromatographically and deposited in a temperature gradient tube filled with quartz grains. Results about the deposition behaviour of the elements were obtained. Two different formalisms based on the thermodynamic functions are used to describe the experimental data. One formula is used to describe the deposition behaviour of microscopic amounts of plutonium (adsorption), the other formula for macroamounts of the main matrix elements (desublimation). The calculated values are in a reasonable agreement with the experimental data. A determination of plutonium content was successfully made for a referenced sea sediment (IAEA-135) after the thermochromatographic sample preparation for ICP-MS. (orig.)

  15. Blood sampling from adrenal gland vein

    International Nuclear Information System (INIS)

    Sun Yong; Ni Caifang

    2009-01-01

    Adrenal gland vein sampling is an interventional method to get the blood samples from the adrenal gland vein. The blood is obtained via a catheter which is selectively inserted in the adrenal gland vein. This technique is mainly used to be diagnostic for primary hyperaldosteronism. A full knowledge of the anatomy and variations of the adrenal gland vein, serious preoperative preparation and skilled catheterization manipulation are necessary for obtaining sufficient blood sample and for reducing the occurrence of complications. Providing the physicians with definite diagnostic evidence and being technically feasible, adrenal gland vein sampling should become one of the routine examinations for clarifying the cause of primary hyperaldosteronism. (authors)

  16. Sampling system and method

    Science.gov (United States)

    Decker, David L.; Lyles, Brad F.; Purcell, Richard G.; Hershey, Ronald Lee

    2013-04-16

    The present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit.

  17. Estimation of reference intervals from small samples: an example using canine plasma creatinine.

    Science.gov (United States)

    Geffré, A; Braun, J P; Trumel, C; Concordet, D

    2009-12-01

    According to international recommendations, reference intervals should be determined from at least 120 reference individuals, which often are impossible to achieve in veterinary clinical pathology, especially for wild animals. When only a small number of reference subjects is available, the possible bias cannot be known and the normality of the distribution cannot be evaluated. A comparison of reference intervals estimated by different methods could be helpful. The purpose of this study was to compare reference limits determined from a large set of canine plasma creatinine reference values, and large subsets of this data, with estimates obtained from small samples selected randomly. Twenty sets each of 120 and 27 samples were randomly selected from a set of 1439 plasma creatinine results obtained from healthy dogs in another study. Reference intervals for the whole sample and for the large samples were determined by a nonparametric method. The estimated reference limits for the small samples were minimum and maximum, mean +/- 2 SD of native and Box-Cox-transformed values, 2.5th and 97.5th percentiles by a robust method on native and Box-Cox-transformed values, and estimates from diagrams of cumulative distribution functions. The whole sample had a heavily skewed distribution, which approached Gaussian after Box-Cox transformation. The reference limits estimated from small samples were highly variable. The closest estimates to the 1439-result reference interval for 27-result subsamples were obtained by both parametric and robust methods after Box-Cox transformation but were grossly erroneous in some cases. For small samples, it is recommended that all values be reported graphically in a dot plot or histogram and that estimates of the reference limits be compared using different methods.

  18. Conformational sampling in template-free protein loop structure modeling: an overview.

    Science.gov (United States)

    Li, Yaohang

    2013-01-01

    Accurately modeling protein loops is an important step to predict three-dimensional structures as well as to understand functions of many proteins. Because of their high flexibility, modeling the three-dimensional structures of loops is difficult and is usually treated as a "mini protein folding problem" under geometric constraints. In the past decade, there has been remarkable progress in template-free loop structure modeling due to advances of computational methods as well as stably increasing number of known structures available in PDB. This mini review provides an overview on the recent computational approaches for loop structure modeling. In particular, we focus on the approaches of sampling loop conformation space, which is a critical step to obtain high resolution models in template-free methods. We review the potential energy functions for loop modeling, loop buildup mechanisms to satisfy geometric constraints, and loop conformation sampling algorithms. The recent loop modeling results are also summarized.

  19. CONFORMATIONAL SAMPLING IN TEMPLATE-FREE PROTEIN LOOP STRUCTURE MODELING: AN OVERVIEW

    Directory of Open Access Journals (Sweden)

    Yaohang Li

    2013-02-01

    Full Text Available Accurately modeling protein loops is an important step to predict three-dimensional structures as well as to understand functions of many proteins. Because of their high flexibility, modeling the three-dimensional structures of loops is difficult and is usually treated as a “mini protein folding problem” under geometric constraints. In the past decade, there has been remarkable progress in template-free loop structure modeling due to advances of computational methods as well as stably increasing number of known structures available in PDB. This mini review provides an overview on the recent computational approaches for loop structure modeling. In particular, we focus on the approaches of sampling loop conformation space, which is a critical step to obtain high resolution models in template-free methods. We review the potential energy functions for loop modeling, loop buildup mechanisms to satisfy geometric constraints, and loop conformation sampling algorithms. The recent loop modeling results are also summarized.

  20. A nested sampling particle filter for nonlinear data assimilation

    KAUST Repository

    Elsheikh, Ahmed H.

    2014-04-15

    We present an efficient nonlinear data assimilation filter that combines particle filtering with the nested sampling algorithm. Particle filters (PF) utilize a set of weighted particles as a discrete representation of probability distribution functions (PDF). These particles are propagated through the system dynamics and their weights are sequentially updated based on the likelihood of the observed data. Nested sampling (NS) is an efficient sampling algorithm that iteratively builds a discrete representation of the posterior distributions by focusing a set of particles to high-likelihood regions. This would allow the representation of the posterior PDF with a smaller number of particles and reduce the effects of the curse of dimensionality. The proposed nested sampling particle filter (NSPF) iteratively builds the posterior distribution by applying a constrained sampling from the prior distribution to obtain particles in high-likelihood regions of the search space, resulting in a reduction of the number of particles required for an efficient behaviour of particle filters. Numerical experiments with the 3-dimensional Lorenz63 and the 40-dimensional Lorenz96 models show that NSPF outperforms PF in accuracy with a relatively smaller number of particles. © 2013 Royal Meteorological Society.

  1. Analytical optimal pulse shapes obtained with the aid of genetic algorithms

    International Nuclear Information System (INIS)

    Guerrero, Rubén D.; Arango, Carlos A.; Reyes, Andrés

    2015-01-01

    We propose a methodology to design optimal pulses for achieving quantum optimal control on molecular systems. Our approach constrains pulse shapes to linear combinations of a fixed number of experimentally relevant pulse functions. Quantum optimal control is obtained by maximizing a multi-target fitness function using genetic algorithms. As a first application of the methodology, we generated an optimal pulse that successfully maximized the yield on a selected dissociation channel of a diatomic molecule. Our pulse is obtained as a linear combination of linearly chirped pulse functions. Data recorded along the evolution of the genetic algorithm contained important information regarding the interplay between radiative and diabatic processes. We performed a principal component analysis on these data to retrieve the most relevant processes along the optimal path. Our proposed methodology could be useful for performing quantum optimal control on more complex systems by employing a wider variety of pulse shape functions

  2. Analytical optimal pulse shapes obtained with the aid of genetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero, Rubén D., E-mail: rdguerrerom@unal.edu.co [Department of Physics, Universidad Nacional de Colombia, Bogota (Colombia); Arango, Carlos A. [Department of Chemical Sciences, Universidad Icesi, Cali (Colombia); Reyes, Andrés [Department of Chemistry, Universidad Nacional de Colombia, Bogota (Colombia)

    2015-09-28

    We propose a methodology to design optimal pulses for achieving quantum optimal control on molecular systems. Our approach constrains pulse shapes to linear combinations of a fixed number of experimentally relevant pulse functions. Quantum optimal control is obtained by maximizing a multi-target fitness function using genetic algorithms. As a first application of the methodology, we generated an optimal pulse that successfully maximized the yield on a selected dissociation channel of a diatomic molecule. Our pulse is obtained as a linear combination of linearly chirped pulse functions. Data recorded along the evolution of the genetic algorithm contained important information regarding the interplay between radiative and diabatic processes. We performed a principal component analysis on these data to retrieve the most relevant processes along the optimal path. Our proposed methodology could be useful for performing quantum optimal control on more complex systems by employing a wider variety of pulse shape functions.

  3. Evaluation of common methods for sampling invertebrate pollinator assemblages: net sampling out-perform pan traps.

    Science.gov (United States)

    Popic, Tony J; Davila, Yvonne C; Wardle, Glenda M

    2013-01-01

    Methods for sampling ecological assemblages strive to be efficient, repeatable, and representative. Unknowingly, common methods may be limited in terms of revealing species function and so of less value for comparative studies. The global decline in pollination services has stimulated surveys of flower-visiting invertebrates, using pan traps and net sampling. We explore the relative merits of these two methods in terms of species discovery, quantifying abundance, function, and composition, and responses of species to changing floral resources. Using a spatially-nested design we sampled across a 5000 km(2) area of arid grasslands, including 432 hours of net sampling and 1296 pan trap-days, between June 2010 and July 2011. Net sampling yielded 22% more species and 30% higher abundance than pan traps, and better reflected the spatio-temporal variation of floral resources. Species composition differed significantly between methods; from 436 total species, 25% were sampled by both methods, 50% only by nets, and the remaining 25% only by pans. Apart from being less comprehensive, if pan traps do not sample flower-visitors, the link to pollination is questionable. By contrast, net sampling functionally linked species to pollination through behavioural observations of flower-visitation interaction frequency. Netted specimens are also necessary for evidence of pollen transport. Benefits of net-based sampling outweighed minor differences in overall sampling effort. As pan traps and net sampling methods are not equivalent for sampling invertebrate-flower interactions, we recommend net sampling of invertebrate pollinator assemblages, especially if datasets are intended to document declines in pollination and guide measures to retain this important ecosystem service.

  4. Energy Preserved Sampling for Compressed Sensing MRI

    Directory of Open Access Journals (Sweden)

    Yudong Zhang

    2014-01-01

    Full Text Available The sampling patterns, cost functions, and reconstruction algorithms play important roles in optimizing compressed sensing magnetic resonance imaging (CS-MRI. Simple random sampling patterns did not take into account the energy distribution in k-space and resulted in suboptimal reconstruction of MR images. Therefore, a variety of variable density (VD based samplings patterns had been developed. To further improve it, we propose a novel energy preserving sampling (ePRESS method. Besides, we improve the cost function by introducing phase correction and region of support matrix, and we propose iterative thresholding algorithm (ITA to solve the improved cost function. We evaluate the proposed ePRESS sampling method, improved cost function, and ITA reconstruction algorithm by 2D digital phantom and 2D in vivo MR brains of healthy volunteers. These assessments demonstrate that the proposed ePRESS method performs better than VD, POWER, and BKO; the improved cost function can achieve better reconstruction quality than conventional cost function; and the ITA is faster than SISTA and is competitive with FISTA in terms of computation time.

  5. Jenis Sample: Keuntungan dan Kerugiannya

    OpenAIRE

    Suprapto, Agus

    1994-01-01

    Sample is a part of a population that are used in a study for purposes of making estimation about the nature of the total population that is obtained with sampling technic. Sampling technic is more adventagous than cencus because it can reduce cost, time, and it can gather deeper information and more accurate data. It is useful to distinguish two major types of sampling technics. First, Prob bility sampling i.e. simple random sampling. Second, Non Probability sampling i.e. systematic sam­plin...

  6. Respiratory motion sampling in 4DCT reconstruction for radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chi Yuwei; Liang Jian; Qin Xu; Yan Di [Department of Radiation Oncology, Columbia University, New York, New York 10032 (United States); Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, Michigan 48073 (United States)

    2012-04-15

    Purpose: Phase-based and amplitude-based sorting techniques are commonly used in four-dimensional CT (4DCT) reconstruction. However, effect of these sorting techniques on 4D dose calculation has not been explored. In this study, the authors investigated a candidate 4DCT sorting technique by comparing its 4D dose calculation accuracy with that for phase-based and amplitude-based sorting techniques.Method: An optimization model was formed using organ motion probability density function (PDF) in the 4D dose convolution. The objective function for optimization was defined as the maximum difference between the expected 4D dose in organ of interest and the 4D dose calculated using a 4DCT sorted by a candidate sampling method. Sorting samples, as optimization variables, were selected on the respiratory motion PDF assessed during the CT scanning. Breathing curves obtained from patients' 4DCT scanning, as well as 3D dose distribution from treatment planning, were used in the study. Given the objective function, a residual error analysis was performed, and k-means clustering was found to be an effective sampling scheme to improve the 4D dose calculation accuracy and independent with the patient-specific dose distribution. Results: Patient data analysis demonstrated that the k-means sampling was superior to the conventional phase-based and amplitude-based sorting and comparable to the optimal sampling results. For phase-based sorting, the residual error in 4D dose calculations may not be further reduced to an acceptable accuracy after a certain number of phases, while for amplitude-based sorting, k-means sampling, and the optimal sampling, the residual error in 4D dose calculations decreased rapidly as the number of 4DCT phases increased to 6.Conclusion: An innovative phase sorting method (k-means method) is presented in this study. The method is dependent only on tumor motion PDF. It could provide a way to refine the phase sorting in 4DCT reconstruction and is effective

  7. Groundwater sampling in uranium reconnaissance

    International Nuclear Information System (INIS)

    Butz, T.R.

    1977-03-01

    The groundwater sampling program is based on the premise that ground water geochemistry reflects the chemical composition of, and geochemical processes active in the strata from which the sample is obtained. Pilot surveys have shown that wells are the best source of groundwater, although springs are sampled on occasion. The procedures followed in selecting a sampling site, the sampling itself, and the field measurements, as well as the site records made, are described

  8. Yttrium orthoferrite powder obtained by the mechanochemical synthesis

    Directory of Open Access Journals (Sweden)

    Lazarević Zorica Ž.

    2017-01-01

    Full Text Available Yttrium orthoferrite (YFeO3 powder was prepared by a mechanochemical synthesis from a mixture of Y2O3 and α-Fe2O3 powders in a planetary ball mill for 2.5 h. The obtained YFeO3 powder sample was characterized by X-ray diffraction (XRD, Raman and infrared spectroscopy. The average crystallite size calculated by the Scherrer equation was 12 nm. The Mössbauer spectroscopy at room temperature confirms the superparamagnetic character of YFeO3 orthoferrite sample. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. III 45003, Grant no. III 45015, Grant no. III 45018

  9. Determination of thermal diffusivity of dental enamel and dentin as a function of temperature, using infrared thermography

    International Nuclear Information System (INIS)

    Pereira, Thiago Martini

    2009-01-01

    In this work it was developed a software that calculates automatically, the thermal diffusivity value as a function of temperature in materials. The infrared thermography technique was used for data acquisition of temperature distribution as a function of time. These data were used to adjust a temperature function obtained from the homogeneous heat equation with specific boundary conditions. For that, an infrared camera (detecting from 8 μm to 9 μm) was calibrated to detect temperature ranging from 185 degree C up to 1300 degree C at an acquisition rate of 300 Hz. It was used, 10 samples of dental enamel and 10 samples of dentin, with 4 mm x 4 mm x 2 mm, which were obtained from bovine lower incisor teeth. These samples were irradiated with an Er:Cr:YSGG pulsed laser (λ = 2,78 μm). The resulting temperature was recorded 2 s prior, 10 s during irradiation and continuing for 2 more seconds after it. After each irradiation, all obtained thermal images were processed in the software, creating a file with the data of thermal diffusivity as a function of temperature. Another file with the thermal diffusivity values was also calculated after each laser pulse. The mean result of thermal diffusivity obtained for dental enamel was 0,0084 ± 0,001 cm2/s for the temperature interval of 220-550 degree C. The mean value for thermal diffusivity obtained for dentin was 0,0015 0,0004 cm2/s in temperatures up to 360 degree C; however, this value increases for higher temperatures. According to these results, it was possible to conclude that the use of infrared thermography, associated with the software developed in this work, is an efficient method to determine the thermal diffusivity values as a function of temperature in different materials. (author)

  10. Asymmetry of characteristic X-ray peaks obtained by a Si(Li) detector

    Energy Technology Data Exchange (ETDEWEB)

    Visnovezky, Claudia [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria, 5000, Cordoba (Argentina)], E-mail: cavy3@hotmail.com; Limandri, Silvina [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria, 5000, Cordoba (Argentina)], E-mail: silvilimandri@hotmail.com; Canafoglia, Maria Elena [Centro de Investigacion y Desarrollo en Ciencias Aplicadas Dr. Jorge Ronco, Calle 47 No 257, 1900 La Plata, Argentina, Facultad de Ciencias Exactas y Facultad de Ingenieria de la UNLP, La Plata (Argentina); Bonetto, Rita [Centro de Investigacion y Desarrollo en Ciencias Aplicadas Dr. Jorge Ronco, Calle 47 No 257, 1900 La Plata, Argentina, Facultad de Ciencias Exactas y Facultad de Ingenieria de la UNLP, La Plata (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas de la Republica Argentina (Argentina)], E-mail: bonetto@quimica.unlp.edu.ar; Trincavelli, Jorge [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria, 5000, Cordoba (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas de la Republica Argentina (Argentina)], E-mail: jorge@quechua.fis.uncor.edu

    2007-05-15

    The asymmetry of the characteristic X-ray peaks obtained using a Si(Li) detector is mainly due to incomplete charge collection. Impurities and defects in the crystalline structure of Si can act as 'traps' for holes and electrons in their trip toward the detector electrodes. Therefore, the collected charge, and consequently the detected energy, is smaller than the expected one. The global effect is that peaks may present a 'tail' toward the low energy side. This phenomenon is more important for low energies (lower than 2.3 keV, in the case of the detector characterized). In this work, the parameters related to peak asymmetry were studied, allowing a better understanding of the trapping process mentioned above. For this purpose, spectra from mono- and multi-element samples were collected for elements with atomic number between 7 and 20. In order to describe the shape of the characteristic K peaks as a function of its energy, an asymmetric correction to a Gaussian function was proposed. Spectra were obtained by electron probe microanalysis for incidence energies between 5 and 25 keV using an energy dispersive spectrometer equipped with an ultra-thin window Si(Li) detector. It was observed that the area corresponding to the asymmetric correction exhibits an energy dependence similar to that of the mass absorption coefficient of the detector material. In addition, other two spectrometers were used to investigate the dependence of tailing on the detection system. When two spectrometers with the same kind of detector and different pulse processors were compared, peaks were more asymmetric for lower peaking time values. When two different detectors were used, differences were even more important.

  11. Special nuclear material inventory sampling plans

    International Nuclear Information System (INIS)

    Vaccaro, H.S.; Goldman, A.S.

    1987-01-01

    This paper presents improved procedures for obtaining statistically valid sampling plans for nuclear facilities. The double sampling concept and methods for developing optimal double sampling plans are described. An algorithm is described that is satisfactory for finding optimal double sampling plans and choosing appropriate detection and false alarm probabilities

  12. Symptom presentation and classroom functioning in a nonclinical sample of children with social phobia.

    Science.gov (United States)

    Bernstein, Gail A; Bernat, Debra H; Davis, Andrew A; Layne, Ann E

    2008-01-01

    This study investigates symptom presentation and school functioning in a nonclinical sample of children with social phobia (SP). Forty-five children with SP were identified via school-wide screenings and follow-up diagnostic interviews. Analyses examined types and intensity of fears, number of social situations avoided, interpersonal relationships, and classroom functioning. To identify characteristics unique to social phobic children, children with SP (n = 45) were compared to anxious children without SP (n = 56) on the above variables. Comorbidity in children with SP and factors associated with SP severity were also evaluated. Compared to anxious children without SP, children with SP feared and avoided a significantly greater number of social situations. In addition, they were significantly more likely to have trouble with making friends and to prefer being alone rather than with peers. All children with SP met criteria for at least one comorbid disorder. Significant factors explaining child-reported severity of SP were number of social situations avoided and intensity of fears. Greater severity of SP was significantly associated with poorer social skills, poorer leadership skills, greater attention difficulties, and greater learning problems in the classroom. It is important to understand the symptom presentation of SP so that children with SP are identified early and effective interventions are instituted. This is especially critical given the impact of SP on school functioning. Published 2007 Wiley-Liss, Inc.

  13. Methods for obtaining distributions of uranium occurrence from estimates of geologic features

    International Nuclear Information System (INIS)

    Ford, C.E.; McLaren, R.A.

    1980-04-01

    The problem addressed in this paper is the determination of a quantitative estimate of a resource from estimates of fundamental variables which describe the resource. Due to uncertainty about the estimates, these basic variables are stochastic. The evaluation of random equations involving these variables is the core of the analysis process. The basic variables are originally described in terms of a low and a high percentile (the 5th and 95th, for example) and a central value (the mode, mean or median). The variable thus described is then generally assumed to be represented by a three-parameter lognormal distribution. Expressions involving these variables are evaluated by computing the first four central moments of the random functions (which are usually products and sums of variables). Stochastic independence is discussed. From the final set of moments a Pearson distribution is obtained; the high values of skewness and kurtosis resulting from uranium data require obtaining Pearson curves beyond those described in published tables. A cubic spline solution to the Pearson differential equation accomplishes this task. A sample problem is used to illustrate the application of the process; sensitivity to the estimated values of the basic variables is discussed. Appendices contain details of the methods and descriptions of computer programs

  14. Methods for obtaining distributions of uranium occurrence from estimates of geologic features

    International Nuclear Information System (INIS)

    Ford, C.E.; McLaren, R.A.

    1980-04-01

    The problem addressed in this report is the determination of a quantitative estimate of a resource from estimates of fundamental variables which describe the resource. Due to uncertainty about the estimates, these basic variables are stochastic. The evaluation of random equations involving these variables is the core of the analysis process. The basic variables are originally described in terms of a low and a high percentile (the 5th and 95th, for example) and a central value (the mode, mean or median). The variable thus described is then generally assumed to be represented by a three-parameter lognormal distribution. Expressions involving these variables are evaluated by computing the first four central moments of the random functions (which are usually products and sums of variables). Stochastic independence is discussed. From the final set of moments a Pearson distribution is obtained; the high values of skewness and kurtosis resulting from uranium data requires obtaining Pearson curves beyond those described in published tables. A cubic spline solution to the Pearson differential equation accomplishes this task. A sample problem is used to illustrate the application of the process; sensitivity to the estimated values of the basic variables is discussed. Appendices contain details of the methods and descriptions of computer programs

  15. Clinical usefulness of physiological components obtained by factor analysis

    International Nuclear Information System (INIS)

    Ohtake, Eiji; Murata, Hajime; Matsuda, Hirofumi; Yokoyama, Masao; Toyama, Hinako; Satoh, Tomohiko.

    1989-01-01

    The clinical usefulness of physiological components obtained by factor analysis was assessed in 99m Tc-DTPA renography. Using definite physiological components, another dynamic data could be analyzed. In this paper, the dynamic renal function after ESWL (Extracorporeal Shock Wave Lithotripsy) treatment was examined using physiological components in the kidney before ESWL and/or a normal kidney. We could easily evaluate the change of renal functions by this method. The usefulness of a new analysis using physiological components was summarized as follows: 1) The change of a dynamic function could be assessed in quantity as that of the contribution ratio. 2) The change of a sick condition could be morphologically evaluated as that of the functional image. (author)

  16. Generalized sampling in Julia

    DEFF Research Database (Denmark)

    Jacobsen, Christian Robert Dahl; Nielsen, Morten; Rasmussen, Morten Grud

    2017-01-01

    Generalized sampling is a numerically stable framework for obtaining reconstructions of signals in different bases and frames from their samples. For example, one can use wavelet bases for reconstruction given frequency measurements. In this paper, we will introduce a carefully documented toolbox...... for performing generalized sampling in Julia. Julia is a new language for technical computing with focus on performance, which is ideally suited to handle the large size problems often encountered in generalized sampling. The toolbox provides specialized solutions for the setup of Fourier bases and wavelets....... The performance of the toolbox is compared to existing implementations of generalized sampling in MATLAB....

  17. New Equipment and Techniques for Remote Sampling of Stored Radioactive Waste

    International Nuclear Information System (INIS)

    Nance, T.A.

    2001-01-01

    Radioactive waste is stored at the Savannah River Site (SRS), part of the Department of Energy (DOE) complex. This radioactive waste is stored in buried tanks and management of the waste requires several processes, including material addition, heating, cooling, mixing, and transfer from tank to tank. During waste processing, it is necessary to know the chemical components and their characteristics to determine the steps necessary to maintain the waste form or to manipulate the waste into the form desired. Waste characterization begins by obtaining a sample for analysis. High level radioactive waste sampling is routinely done with simple, standard samplers such as a dip sample. Other sampling is non-routine or specialized, with unique, special requirements, such as sampling remote areas that are difficult to reach. Other specialized sampling includes sampling materials with unknown characteristics or material that must be gathered to obtain an adequate sample or materials that must be broken up to sample or forcibly separated from the tank. The samplers described in this paper are specialized samplers. These samplers include the Dip Filter Sampler, Soft Core Sampler, Hard Core Sampler, Circle Scrape Sampler, Small Scrape Sampler, Suction and Strain Sampler, and Vial Snapper Sampler. The Dip Filter Sampler is used to sample floating particulate matter or floating organic matter. The Soft Core Sampler and Hard Core Sampler are used to obtain samples of solids from the tank floor. The Soft Core Sampler is used on soft solids such as sludge and saltcake and the Hard Core Sampler on hardened solid deposits. The Circle Scrape Sampler is used to obtain solid samples through a small entry riser and out from under the riser. The Small Scrape Sampler enters a small entry riser and is used to scrape a sample from the tank wall. The Suction and Strain Sampler is used to gather a remote submerged sample or filter a solid sample from supernate. The Vial Snapper Grab Sampler is

  18. A Method against Interrupted-Sampling Repeater Jamming Based on Energy Function Detection and Band-Pass Filtering

    Directory of Open Access Journals (Sweden)

    Hui Yuan

    2017-01-01

    Full Text Available Interrupted-sampling repeater jamming (ISRJ is a new kind of coherent jamming to the large time-bandwidth linear frequency modulation (LFM signal. Many jamming modes, such as lifelike multiple false targets and dense false targets, can be made through setting up different parameters. According to the “storage-repeater-storage-repeater” characteristics of the ISRJ and the differences in the time-frequency-energy domain between the ISRJ signal and the target echo signal, one new method based on the energy function detection and band-pass filtering is proposed to suppress the ISRJ. The methods mainly consist of two parts: extracting the signal segments without ISRJ and constructing band-pass filtering function with low sidelobe. The simulation results show that the method is effective in the ISRJ with different parameters.

  19. Large Sample Neutron Activation Analysis of Heterogeneous Samples

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Vasilopoulou, T.; Tzika, F.

    2018-01-01

    A Large Sample Neutron Activation Analysis (LSNAA) technique was developed for non-destructive analysis of heterogeneous bulk samples. The technique incorporated collimated scanning and combining experimental measurements and Monte Carlo simulations for the identification of inhomogeneities in large volume samples and the correction of their effect on the interpretation of gamma-spectrometry data. Corrections were applied for the effect of neutron self-shielding, gamma-ray attenuation, geometrical factor and heterogeneous activity distribution within the sample. A benchmark experiment was performed to investigate the effect of heterogeneity on the accuracy of LSNAA. Moreover, a ceramic vase was analyzed as a whole demonstrating the feasibility of the technique. The LSNAA results were compared against results obtained by INAA and a satisfactory agreement between the two methods was observed. This study showed that LSNAA is a technique capable to perform accurate non-destructive, multi-elemental compositional analysis of heterogeneous objects. It also revealed the great potential of the technique for the analysis of precious objects and artefacts that need to be preserved intact and cannot be damaged for sampling purposes. (author)

  20. Evaluation of volatile profiles obtained for minimally-processed pineapple fruit samples during storage by headspace-solid phase microextraction gas chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Francielle Crocetta TURAZZI

    Full Text Available Abstract This paper describes the application of the solid-phase microextraction (SPME technique for the determination and monitoring of the volatile profile of minimally-processed pineapple fruit stored at various temperatures (-12 °C, 4 °C and 25 °C for different periods (1, 4 and 10 days. The SPME fiber coating composed of Car/PDMS presented the best performance. The optimal extraction conditions obtained through a Doehlert design were 60 min at 35 °C. The profiles for the volatile compounds content of the fruit at each stage of storage were determined by gas chromatography-mass spectrometry (GC-MS. The variation in the volatile profile over time was greater when the fruit samples were stored at 25 °C and at -12 °C compared to 4 °C. Thus, according to the volatile profiles associated with the storage conditions evaluated in this study, packaged pineapple retains best its fresh fruit aroma when stored at 4 °C.

  1. Enhanced sampling algorithms.

    Science.gov (United States)

    Mitsutake, Ayori; Mori, Yoshiharu; Okamoto, Yuko

    2013-01-01

    In biomolecular systems (especially all-atom models) with many degrees of freedom such as proteins and nucleic acids, there exist an astronomically large number of local-minimum-energy states. Conventional simulations in the canonical ensemble are of little use, because they tend to get trapped in states of these energy local minima. Enhanced conformational sampling techniques are thus in great demand. A simulation in generalized ensemble performs a random walk in potential energy space and can overcome this difficulty. From only one simulation run, one can obtain canonical-ensemble averages of physical quantities as functions of temperature by the single-histogram and/or multiple-histogram reweighting techniques. In this article we review uses of the generalized-ensemble algorithms in biomolecular systems. Three well-known methods, namely, multicanonical algorithm, simulated tempering, and replica-exchange method, are described first. Both Monte Carlo and molecular dynamics versions of the algorithms are given. We then present various extensions of these three generalized-ensemble algorithms. The effectiveness of the methods is tested with short peptide and protein systems.

  2. UV irradiation of track membranes as a method for obtaining the necessary value of brittleness for good fractures of samples for sem observations

    International Nuclear Information System (INIS)

    Sartowska, B.; Nowicki, A.; Orelovitch, O.; )

    2006-01-01

    Synthesis of nano- and microstructures of materials inside the pores of specific template-track membranes can be used to obtain nano- and microwires or nano- and microtubes. It is important for these applications to know the inner geometry of the pores like sizes, shape and surface morphology. Scanning electron microscopy technique (SEM) was used predominantly for this kind of membrane characterisation. The use of other methods of sample preparation as electron, gamma rays or UV irradiation allows to make them more brittle. In present paper authors describe preliminary results of the tensile measurements of membranes after UV irradiation. Poly(ethylene terephthalate) (PET) membrane 10 μm thick with pore diameter 1.0 μm were prepared t the Joint Institute for Nuclear Research (Dubna, Russia) using the standard procedure. The samples were irradiated with UV light with energy flux 2.8 W/cm 2 during different periods of time. The tensile measurements of the initial and irradiated materials were carried in the Institute of Nuclear Chemistry and Technology (Warsaw, Poland). In conclusion, authors claim that it is possible to find the dose of UV irradiation that ensures the fracture without elastic deformation. In the case when the time of UV irradiation increases up to 90 h, the PET membrane breaks without distortion of its channel structure

  3. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  4. Failure-censored accelerated life test sampling plans for Weibull distribution under expected test time constraint

    International Nuclear Information System (INIS)

    Bai, D.S.; Chun, Y.R.; Kim, J.G.

    1995-01-01

    This paper considers the design of life-test sampling plans based on failure-censored accelerated life tests. The lifetime distribution of products is assumed to be Weibull with a scale parameter that is a log linear function of a (possibly transformed) stress. Two levels of stress higher than the use condition stress, high and low, are used. Sampling plans with equal expected test times at high and low test stresses which satisfy the producer's and consumer's risk requirements and minimize the asymptotic variance of the test statistic used to decide lot acceptability are obtained. The properties of the proposed life-test sampling plans are investigated

  5. Evaluation of common methods for sampling invertebrate pollinator assemblages: net sampling out-perform pan traps.

    Directory of Open Access Journals (Sweden)

    Tony J Popic

    Full Text Available Methods for sampling ecological assemblages strive to be efficient, repeatable, and representative. Unknowingly, common methods may be limited in terms of revealing species function and so of less value for comparative studies. The global decline in pollination services has stimulated surveys of flower-visiting invertebrates, using pan traps and net sampling. We explore the relative merits of these two methods in terms of species discovery, quantifying abundance, function, and composition, and responses of species to changing floral resources. Using a spatially-nested design we sampled across a 5000 km(2 area of arid grasslands, including 432 hours of net sampling and 1296 pan trap-days, between June 2010 and July 2011. Net sampling yielded 22% more species and 30% higher abundance than pan traps, and better reflected the spatio-temporal variation of floral resources. Species composition differed significantly between methods; from 436 total species, 25% were sampled by both methods, 50% only by nets, and the remaining 25% only by pans. Apart from being less comprehensive, if pan traps do not sample flower-visitors, the link to pollination is questionable. By contrast, net sampling functionally linked species to pollination through behavioural observations of flower-visitation interaction frequency. Netted specimens are also necessary for evidence of pollen transport. Benefits of net-based sampling outweighed minor differences in overall sampling effort. As pan traps and net sampling methods are not equivalent for sampling invertebrate-flower interactions, we recommend net sampling of invertebrate pollinator assemblages, especially if datasets are intended to document declines in pollination and guide measures to retain this important ecosystem service.

  6. Acceptance sampling using judgmental and randomly selected samples

    Energy Technology Data Exchange (ETDEWEB)

    Sego, Landon H.; Shulman, Stanley A.; Anderson, Kevin K.; Wilson, John E.; Pulsipher, Brent A.; Sieber, W. Karl

    2010-09-01

    We present a Bayesian model for acceptance sampling where the population consists of two groups, each with different levels of risk of containing unacceptable items. Expert opinion, or judgment, may be required to distinguish between the high and low-risk groups. Hence, high-risk items are likely to be identifed (and sampled) using expert judgment, while the remaining low-risk items are sampled randomly. We focus on the situation where all observed samples must be acceptable. Consequently, the objective of the statistical inference is to quantify the probability that a large percentage of the unsampled items in the population are also acceptable. We demonstrate that traditional (frequentist) acceptance sampling and simpler Bayesian formulations of the problem are essentially special cases of the proposed model. We explore the properties of the model in detail, and discuss the conditions necessary to ensure that required samples sizes are non-decreasing function of the population size. The method is applicable to a variety of acceptance sampling problems, and, in particular, to environmental sampling where the objective is to demonstrate the safety of reoccupying a remediated facility that has been contaminated with a lethal agent.

  7. Pulsed Direct Current Electrospray: Enabling Systematic Analysis of Small Volume Sample by Boosting Sample Economy.

    Science.gov (United States)

    Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong

    2015-11-17

    We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.

  8. Analysis of submicrogram samples by INAA

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrom, D J [National Aeronautics and Space Administration, Houston, TX (USA). Lyndon B. Johnson Space Center

    1990-12-20

    Procedure have been developed to increase the sensitivity of instrumental neutron activation analysis (INAA) so that cosmic-dust samples weighing only 10{sup -9}-10{sup -7} g are routinely analyzed for a sizable number of elements. The primary differences from standard techniques are: (1) irradiation of the samples is much more intense, (2) gamma ray assay of the samples is done using long counting times and large Ge detectors that are operated in an excellent low-background facility, (3) specially prepared glass standards are used, (4) samples are too small to be weighed routinely and concentrations must be obtained indirectly, (5) sample handling is much more difficult, and contamination of small samples with normally insignificant amounts of contaminants is difficult to prevent. In spite of the difficulties, INAA analyses have been done on 15 cosmic-dust particles and a large number of other stratospheric particles. Two-sigma detection limits for some elements are in the range of femtograms (10{sup -15} g), e.g. Co=11, Sc=0.9, Sm=0.2 A particle weighing just 0.2 ng was analyzed, obtaining abundances with relative analytical uncertainties of less than 10% for four elements (Fe, Co, Ni and Sc), which were sufficient to allow identification of the particle as chondritic interplanetary dust. Larger samples allow abundances of twenty or more elements to be obtained. (orig.).

  9. BWIP-RANDOM-SAMPLING, Random Sample Generation for Nuclear Waste Disposal

    International Nuclear Information System (INIS)

    Sagar, B.

    1989-01-01

    1 - Description of program or function: Random samples for different distribution types are generated. Distribution types as required for performance assessment modeling of geologic nuclear waste disposal are provided. These are: - Uniform, - Log-uniform (base 10 or natural), - Normal, - Lognormal (base 10 or natural), - Exponential, - Bernoulli, - User defined continuous distribution. 2 - Method of solution: A linear congruential generator is used for uniform random numbers. A set of functions is used to transform the uniform distribution to the other distributions. Stratified, rather than random, sampling can be chosen. Truncated limits can be specified on many distributions, whose usual definition has an infinite support. 3 - Restrictions on the complexity of the problem: Generation of correlated random variables is not included

  10. Simple street tree sampling

    Science.gov (United States)

    David J. Nowak; Jeffrey T. Walton; James Baldwin; Jerry. Bond

    2015-01-01

    Information on street trees is critical for management of this important resource. Sampling of street tree populations provides an efficient means to obtain street tree population information. Long-term repeat measures of street tree samples supply additional information on street tree changes and can be used to report damages from catastrophic events. Analyses of...

  11. Multiscale simulations of patchy particle systems combining Molecular Dynamics, Path Sampling and Green's Function Reaction Dynamics

    Science.gov (United States)

    Bolhuis, Peter

    Important reaction-diffusion processes, such as biochemical networks in living cells, or self-assembling soft matter, span many orders in length and time scales. In these systems, the reactants' spatial dynamics at mesoscopic length and time scales of microns and seconds is coupled to the reactions between the molecules at microscopic length and time scales of nanometers and milliseconds. This wide range of length and time scales makes these systems notoriously difficult to simulate. While mean-field rate equations cannot describe such processes, the mesoscopic Green's Function Reaction Dynamics (GFRD) method enables efficient simulation at the particle level provided the microscopic dynamics can be integrated out. Yet, many processes exhibit non-trivial microscopic dynamics that can qualitatively change the macroscopic behavior, calling for an atomistic, microscopic description. The recently developed multiscale Molecular Dynamics Green's Function Reaction Dynamics (MD-GFRD) approach combines GFRD for simulating the system at the mesocopic scale where particles are far apart, with microscopic Molecular (or Brownian) Dynamics, for simulating the system at the microscopic scale where reactants are in close proximity. The association and dissociation of particles are treated with rare event path sampling techniques. I will illustrate the efficiency of this method for patchy particle systems. Replacing the microscopic regime with a Markov State Model avoids the microscopic regime completely. The MSM is then pre-computed using advanced path-sampling techniques such as multistate transition interface sampling. I illustrate this approach on patchy particle systems that show multiple modes of binding. MD-GFRD is generic, and can be used to efficiently simulate reaction-diffusion systems at the particle level, including the orientational dynamics, opening up the possibility for large-scale simulations of e.g. protein signaling networks.

  12. Microbiological quality of five potato products obtained at retail markets.

    OpenAIRE

    Duran, A P; Swartzentruber, A; Lanier, J M; Wentz, B A; Schwab, A H; Barnard, R J; Read, R B

    1982-01-01

    The microbiological quality of frozen hash brown potatoes, dried hash brown potatoes with onions, frozen french fried potatoes, dried instant mashed potatoes, and potato salad was determined by a national sampling at the retail level. A wide range of results was obtained, with most sampling units of each products having excellent microbiological quality. Geometric mean aerobic plate counts were as follows: dried hash brown potatoes, 270/g; frozen hash brown potatoes with onions, 580/g; frozen...

  13. A novel type of electrochemical sensor based on ferromagnetic carbon-encapsulated iron nanoparticles for direct determination of hemoglobin in blood samples.

    Science.gov (United States)

    Matysiak, Edyta; Donten, Mikolaj; Kowalczyk, Agata; Bystrzejewski, Michal; Grudzinski, Ireneusz P; Nowicka, Anna M

    2015-02-15

    An effective, fast, facile and direct electrochemical method of determination of hemoglobin (Hb) in blood sample without any sample preparation is described. The method is accomplished by using the ferromagnetic electrode modifier (carbon-encapsulated iron nanoparticles) and an external magnetic field. The successful voltammetric determination of hemoglobin is achieved in PBS buffer as well as in the whole blood sample. The obtained results show the excellent electroactivity of Hb. The measurements are of high sensitivity and good reproducibility. The detection limit is estimated to be 0.7 pM. The electrochemical determination data were compared with the gravimetric data obtained with a quartz crystal microbalance. The agreement between these results is very good. The changes of the electrode surface morphology before and after Hb detection are monitored by electron microscopy. The functionality of the electrochemical sensor is tested with human and rat blood samples. The concentration of hemoglobin in the blood samples determined by using voltammetric/gravimetric detection is in perfect agreement with the data obtained from typical clinical analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Bionic Design for Mars Sampling Scoop Inspired by Himalayan Marmot Claw

    Directory of Open Access Journals (Sweden)

    Long Xue

    2016-01-01

    Full Text Available Cave animals are often adapted to digging and life underground, with claw toes similar in structure and function to a sampling scoop. In this paper, the clawed toes of the Himalayan marmot were selected as a biological prototype for bionic research. Based on geometric parameter optimization of the clawed toes, a bionic sampling scoop for use on Mars was designed. Using a 3D laser scanner, the point cloud data of the second front claw toe was acquired. Parametric equations and contour curves for the claw were then built with cubic polynomial fitting. We obtained 18 characteristic curve equations for the internal and external contours of the claw. A bionic sampling scoop was designed according to the structural parameters of Curiosity’s sampling shovel and the contours of the Himalayan marmot’s claw. Verifying test results showed that when the penetration angle was 45° and the sampling speed was 0.33 r/min, the bionic sampling scoops’ resistance torque was 49.6% less than that of the prototype sampling scoop. When the penetration angle was 60° and the sampling speed was 0.22 r/min, the resistance torque of the bionic sampling scoop was 28.8% lower than that of the prototype sampling scoop.

  15. Carbon/Clay nanostructured composite obtained by hydrothermal method

    International Nuclear Information System (INIS)

    Barin, G.B.; Bispo, T.S.; Gimenez, I.F.; Barreto, L.S.; Souza Filho, A.G.

    2010-01-01

    The development of strategies for converting biomass into useful materials, more efficient energy carrier and / or hydrogen storage is shown a key issue for the present and future. Carbon nanostructure can be obtained by severe processing techniques such as arc discharge, chemical deposition and catalyzed pyrolysis of organic compounds. In this study we used hydrothermal methods for obtaining nanostructured composites of carbon / clay. To this end, we used coir dust and special clays. The samples were characterized by infrared spectroscopy, X-ray diffraction and Raman. The presence of the D band at 1350 cm -1 in the Raman spectrum shows the formation of amorphous carbon with particle size of about 8.85 nm. (author)

  16. 20 CFR 416.1014 - Responsibilities for obtaining evidence to make disability determinations.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Responsibilities for obtaining evidence to make disability determinations. 416.1014 Section 416.1014 Employees' Benefits SOCIAL SECURITY... Responsibilities for Performing the Disability Determination Function § 416.1014 Responsibilities for obtaining...

  17. 20 CFR 404.1614 - Responsibilities for obtaining evidence to make disability determinations.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Responsibilities for obtaining evidence to make disability determinations. 404.1614 Section 404.1614 Employees' Benefits SOCIAL SECURITY... Responsibilities for Performing the Disability Determination Function § 404.1614 Responsibilities for obtaining...

  18. Obtaining carbon nanotubes/ZnO for use in the photocatalytic organic pollutants

    International Nuclear Information System (INIS)

    Dalt, S. da; Pulcinelli, N.O.; Bergmann, C.P.

    2016-01-01

    This study aims to obtain nanocomposites of carbon nanotubes (CNTs) with nanostructured zinc oxide (ZnO), and characterize the samples as its structure and photocatalytic activity, for their application in the degradation of organic pollutants, in the case organic dye methyl orange. The nanocomposites were obtained from commercial NTC (Baytubes®), commercial ZnO, produced by Merck and ZnO obtained from the synthesis by combustion. The NTC-ZnO nanocomposites were prepared in solution from the physical mixture of materials, and subsequently analyzed structurally and investigated for their photocatalytic activity, employing them as catalysts in degradation of the dye in aqueous solution under ultraviolet radiation. Samples were analyzed by X-ray diffraction and specific surface area (BET). The photocatalytic performance of nanocomposites can be correlated to the phase found and the surface area measured. (author)

  19. Sample representativeness verification of the FADN CZ farm business sample

    Directory of Open Access Journals (Sweden)

    Marie Prášilová

    2011-01-01

    Full Text Available Sample representativeness verification is one of the key stages of statistical work. After having joined the European Union the Czech Republic joined also the Farm Accountancy Data Network system of the Union. This is a sample of bodies and companies doing business in agriculture. Detailed production and economic data on the results of farming business are collected from that sample annually and results for the entire population of the country´s farms are then estimated and assessed. It is important hence, that the sample be representative. Representativeness is to be assessed as to the number of farms included in the survey and also as to the degree of accordance of the measures and indices as related to the population. The paper deals with the special statistical techniques and methods of the FADN CZ sample representativeness verification including the necessary sample size statement procedure. The Czech farm population data have been obtained from the Czech Statistical Office data bank.

  20. Utilization of Weibull equation to obtain soil-water diffusivity in horizontal infiltration

    International Nuclear Information System (INIS)

    Guerrini, I.A.

    1982-06-01

    Water movement was studied in horizontal infiltration experiments using laboratory columns of air-dry and homogeneous soil to obtain a simple and suitable equation for soil-water diffusivity. Many water content profiles for each one of the ten soil columns utilized were obtained through gamma-ray attenuation technique using a 137 Cs source. During the measurement of a particular water content profile, the soil column was held in the same position in order to measure changes in time and so to reduce the errors in water content determination. The Weibull equation utilized was excellent in fitting water content profiles experimental data. The use of an analytical function for ν, the Boltzmann variable, according to Weibull model, allowed to obtain a simple equation for soil water diffusivity. Comparisons among the equation here obtained for diffusivity and others solutions found in literature were made, and the unsuitability of a simple exponential variation of diffusivity with water content for the full range of the latter was shown. The necessity of admitting the time dependency for diffusivity was confirmed and also the possibility fixing that dependency on a well known value extended to generalized soil water infiltration studies was found. Finally, it was shown that the soil water diffusivity function given by the equation here proposed can be obtained just by the analysis of the wetting front advance as a function of time. (Author) [pt

  1. Standard practices for sampling uranium-Ore concentrate

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These practices are intended to provide the nuclear industry with procedures for obtaining representative bulk samples from uranium-ore concentrates (UOC) (see Specification C967). 1.2 These practices also provide for obtaining a series of representative secondary samples from the original bulk sample for the determination of moisture and other test purposes, and for the preparation of pulverized analytical samples (see Test Methods C1022). 1.3 These practices consist of a number of alternative procedures for sampling and sample preparation which have been shown to be satisfactory through long experience in the nuclear industry. These procedures are described in the following order. Stage Procedure Section Primary Sampling One-stage falling stream 4 Two-stage falling stream 5 Auger 6 Secondary Sampling Straight-path (reciprocating) 7 Rotating (Vezin) 8, 9 Sample Preparation 10 Concurrent-drying 11-13 Natural moisture 14-16 Calcination 17, 18 Sample Packaging 19 Wax s...

  2. Symmetry relationships for multiple scattering of polarized light in turbid spherical samples: theory and a Monte Carlo simulation.

    Science.gov (United States)

    Otsuki, Soichi

    2016-02-01

    This paper presents a theory describing totally incoherent multiple scattering of turbid spherical samples. It is proved that if reciprocity and mirror symmetry hold for single scattering by a particle, they also hold for multiple scattering in spherical samples. Monte Carlo simulations generate a reduced effective scattering Mueller matrix, which virtually satisfies reciprocity and mirror symmetry. The scattering matrix was factorized by using the symmetric decomposition in a predefined form, as well as the Lu-Chipman polar decomposition, approximately into a product of a pure depolarizer and vertically oriented linear retarding diattenuators. The parameters of these components were calculated as a function of the polar angle. While the turbid spherical sample is a pure depolarizer at low polar angles, it obtains more functions of the retarding diattenuator with increasing polar angle.

  3. System design specification for rotary mode core sample trucks No. 2, 3, and 4 programmable logic controller

    International Nuclear Information System (INIS)

    Dowell, J.L.; Akers, J.C.

    1995-01-01

    The system this document describes controls several functions of the Core Sample Truck(s) used to obtain nuclear waste samples from various underground storage tanks at Hanford. The system will monitor the sampling process and provide alarms and other feedback to insure the sampling process is performed within the prescribed operating envelope. The intended audience for this document is anyone associated with rotary or push mode core sampling. This document describes the Alarm and Control logic installed on Rotary Mode Core Sample Trucks (RMCST) number-sign 2, 3, and 4. It is intended to define the particular requirements of the RMCST alarm and control operation (not defined elsewhere) sufficiently for detailed design to implement on a Programmable Logic Controller (PLC)

  4. The possibility of obtaining beta-anhydrite from waste nitrogypsum

    Directory of Open Access Journals (Sweden)

    Marinković S.

    2004-01-01

    Full Text Available The possibility of obtaining β - anhydrite from nitrogypsum, which is waste from a nitrocellulose plant, was investigated. It was shown by means of qualitative IR analysis that the product obtained by heating nitrogypsum for 5 hours at 700 o C was â - anhydrite. When the β- anhydrite was mixed with water at a W/S (water/solid ratio of 0.54 in presence of different accelerators (CaO, mixture CaO - ash, ash, Na2SO4 and K2SO4, pastes were formed which hardened on standing. The compressive strength of the hardened samples was measured after 7 and 28 days and their composition determined by qualitative IR analysis. On the basis of these results, it was observed that a relationship exists between the composition (depending on the used accelerator and the compression strength of the samples. Namely, the formation of large cores of double salts: syngenite (K2SO4 ⋅CaSO4 ⋅H2O and glauberite (Na2SO4 ⋅CaSO4, in the presence of the accelerators K2SO4 and Na2SO4, respectively, was due to the rapid and complete crystallization of the dihydrate (CaSO4 ⋅2H2O. This fast crystal growth of the dihydrate resulted in high compressive strengths of these samples. In the other samples (prepared in presence of the accelerators: CaO, mixture CaO - ash and ash, dihydrate did not form and, consequently, their compressive strength was low.

  5. Comparison of different methodologies for obtaining nickel nanoferrites

    Energy Technology Data Exchange (ETDEWEB)

    Galindo, R.; Menendez, N. [Departamento de Química Física Aplicada, Facultad de Ciencias, Universidad Autónoma de Madrid, Cantoblanco, E-28049 Madrid (Spain); Crespo, P.; Velasco, V. [Instituto de Magnetismo Aplicado, UCM, ADIF CSIC, E-28230 Madrid (Spain); Bomati-Miguel, O.; Díaz-Fernández, D. [Departamento de Física Aplicada and Instituto Nicolás Cabrera, Facultad de Ciencias Universidad Autónoma de Madrid, Cantoblanco, E-28049 Madrid (Spain); Herrasti, P., E-mail: pilar.herrasti@uam.es [Departamento de Química Física Aplicada, Facultad de Ciencias, Universidad Autónoma de Madrid, Cantoblanco, E-28049 Madrid (Spain)

    2014-06-01

    Nickel nanoferrites were obtained by means of four different synthetic wet-routes: co-precipitation (CP), sonochemistry (SC), sonoelectrochemistry (SE) and electrochemistry (E). The influence of the synthesis method on the structural and magnetic properties of nickel ferrite nanoparticles is studied. Although similar experimental conditions such as temperature, pH and time of synthesis were used, a strong dependence of composition and microstructure on the synthesis procedure is found, as electron microscopy, X-ray diffraction and Mössbauer spectroscopy studies reveal. Whereas by means of the CP and SC methods particles of a small size around 5–10 nm, respectively, and composed by different phases are obtained, the electrochemical routes (E and SE) allow obtaining monodisperse nanoparticles, with sizes ranging from 30 to 40 nm, and very close to stoichiometry. Magnetic characterization evidences a superparamagnetic behavior for samples obtained by CP and SC methods, whereas the electrochemical route leads to ferromagnetic ferrite nanoparticles. - Highlights: • Electrochemical synthesis produces pure NiFe{sub 2}O{sub 4} nanonoparticles with 40 nm particle size. • Coprecipitation and sonochemistry techniques generate NiFe{sub 2}O{sub 4} nanoparticles with impurities. • Nanoparticles obtained by coprecipitation and sonochemistry are superparamagnetic. • Electrochemical and sonoelectrochemical methods produce ferromagnetic nanoparticles.

  6. Autofluorescence in samples obtained from chronic biofilm infections – “all that glitters is not gold”

    DEFF Research Database (Denmark)

    Eickhardt-Dalbøge, Steffen Robert; Kragh, Kasper N.; Schrøder, Stine

    2015-01-01

    When looking at tissue sections of ex vivo samples, autofluorescence can be a major cause of artifacts and misinterpretations. We here reiterate evidence that autofluorescing granules, often hemosiderin but also ceroid or mucinogen granules, are severe obstacles when imaging and diagnosing biofil...

  7. An open-chain imaginary-time path-integral sampling approach to the calculation of approximate symmetrized quantum time correlation functions

    Science.gov (United States)

    Cendagorta, Joseph R.; Bačić, Zlatko; Tuckerman, Mark E.

    2018-03-01

    We introduce a scheme for approximating quantum time correlation functions numerically within the Feynman path integral formulation. Starting with the symmetrized version of the correlation function expressed as a discretized path integral, we introduce a change of integration variables often used in the derivation of trajectory-based semiclassical methods. In particular, we transform to sum and difference variables between forward and backward complex-time propagation paths. Once the transformation is performed, the potential energy is expanded in powers of the difference variables, which allows us to perform the integrals over these variables analytically. The manner in which this procedure is carried out results in an open-chain path integral (in the remaining sum variables) with a modified potential that is evaluated using imaginary-time path-integral sampling rather than requiring the generation of a large ensemble of trajectories. Consequently, any number of path integral sampling schemes can be employed to compute the remaining path integral, including Monte Carlo, path-integral molecular dynamics, or enhanced path-integral molecular dynamics. We believe that this approach constitutes a different perspective in semiclassical-type approximations to quantum time correlation functions. Importantly, we argue that our approximation can be systematically improved within a cumulant expansion formalism. We test this approximation on a set of one-dimensional problems that are commonly used to benchmark approximate quantum dynamical schemes. We show that the method is at least as accurate as the popular ring-polymer molecular dynamics technique and linearized semiclassical initial value representation for correlation functions of linear operators in most of these examples and improves the accuracy of correlation functions of nonlinear operators.

  8. An open-chain imaginary-time path-integral sampling approach to the calculation of approximate symmetrized quantum time correlation functions.

    Science.gov (United States)

    Cendagorta, Joseph R; Bačić, Zlatko; Tuckerman, Mark E

    2018-03-14

    We introduce a scheme for approximating quantum time correlation functions numerically within the Feynman path integral formulation. Starting with the symmetrized version of the correlation function expressed as a discretized path integral, we introduce a change of integration variables often used in the derivation of trajectory-based semiclassical methods. In particular, we transform to sum and difference variables between forward and backward complex-time propagation paths. Once the transformation is performed, the potential energy is expanded in powers of the difference variables, which allows us to perform the integrals over these variables analytically. The manner in which this procedure is carried out results in an open-chain path integral (in the remaining sum variables) with a modified potential that is evaluated using imaginary-time path-integral sampling rather than requiring the generation of a large ensemble of trajectories. Consequently, any number of path integral sampling schemes can be employed to compute the remaining path integral, including Monte Carlo, path-integral molecular dynamics, or enhanced path-integral molecular dynamics. We believe that this approach constitutes a different perspective in semiclassical-type approximations to quantum time correlation functions. Importantly, we argue that our approximation can be systematically improved within a cumulant expansion formalism. We test this approximation on a set of one-dimensional problems that are commonly used to benchmark approximate quantum dynamical schemes. We show that the method is at least as accurate as the popular ring-polymer molecular dynamics technique and linearized semiclassical initial value representation for correlation functions of linear operators in most of these examples and improves the accuracy of correlation functions of nonlinear operators.

  9. A Multidimensional Examination of the Acculturation and Psychological Functioning of a Sample of Immigrant Chinese Mothers in the US

    Science.gov (United States)

    Tahseen, Madiha; Cheah, Charissa S. L.

    2012-01-01

    The present research used the cluster analysis method to examine the acculturation of immigrant Chinese mothers (ICMs), and the demographic characteristics and psychological functioning associated with each acculturation style. The sample was comprised of 83 first-generation ICMs of preschool children residing in Maryland, United States (US).…

  10. Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology.

    Science.gov (United States)

    Pradíes, Guillermo; Zarauz, Cristina; Valverde, Arelhys; Ferreiroa, Alberto; Martínez-Rus, Francisco

    2015-02-01

    The aim of this study was to compare the fit of ceramic crowns fabricated from conventional silicone impressions with the fit of ceramic crowns fabricated from intraoral digital impressions. Twenty-five participants with 30 posterior teeth with a prosthetic demand were selected for the study. Two crowns were made for each preparation. One crown was fabricated from an intraoral digital impression system (IDI group) and the other crown was fabricated from a conventional two-step silicone impression (CI group). To replicate the interface between the crown and the preparation, each crown was cemented on its corresponding clinical preparation with ultra-flow silicone. Each crown was embedded in acrylic resin to stabilise the registered interface and then cut in 2mm thick slices in a buco-lingual orientation. The internal gap was determined as the vertical distance from the internal surface of the crown to the prepared tooth surface at four points (marginal gap, axial gap, crest gap, and occlusal fossa gap) using stereomicroscopy with a magnification of 40×. Data was analysed by using Wilcoxon signed rank test (α=0.05). Internal adaptation values were significantly affected by the impression technique (p=0.001). Mean marginal gap was 76.33 ± 65.32 μm for the crowns of the IDI group and 91.46 ± 72.17 μm for the CI group. All-ceramic crowns fabricated from intraoral digital impressions with wavefront sampling technology demonstrated better internal fit than crowns manufactured from silicone impressions. Impressions obtained from an intraoral digital scanner based on wavefront sampling technology can be used for manufacturing ceramic crowns in the normal clinical practice with better results than conventional impressions with elastomers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Classical boson sampling algorithms with superior performance to near-term experiments

    Science.gov (United States)

    Neville, Alex; Sparrow, Chris; Clifford, Raphaël; Johnston, Eric; Birchall, Patrick M.; Montanaro, Ashley; Laing, Anthony

    2017-12-01

    It is predicted that quantum computers will dramatically outperform their conventional counterparts. However, large-scale universal quantum computers are yet to be built. Boson sampling is a rudimentary quantum algorithm tailored to the platform of linear optics, which has sparked interest as a rapid way to demonstrate such quantum supremacy. Photon statistics are governed by intractable matrix functions, which suggests that sampling from the distribution obtained by injecting photons into a linear optical network could be solved more quickly by a photonic experiment than by a classical computer. The apparently low resource requirements for large boson sampling experiments have raised expectations of a near-term demonstration of quantum supremacy by boson sampling. Here we present classical boson sampling algorithms and theoretical analyses of prospects for scaling boson sampling experiments, showing that near-term quantum supremacy via boson sampling is unlikely. Our classical algorithm, based on Metropolised independence sampling, allowed the boson sampling problem to be solved for 30 photons with standard computing hardware. Compared to current experiments, a demonstration of quantum supremacy over a successful implementation of these classical methods on a supercomputer would require the number of photons and experimental components to increase by orders of magnitude, while tackling exponentially scaling photon loss.

  12. Nonuniform sampling by quantiles

    Science.gov (United States)

    Craft, D. Levi; Sonstrom, Reilly E.; Rovnyak, Virginia G.; Rovnyak, David

    2018-03-01

    A flexible strategy for choosing samples nonuniformly from a Nyquist grid using the concept of statistical quantiles is presented for broad classes of NMR experimentation. Quantile-directed scheduling is intuitive and flexible for any weighting function, promotes reproducibility and seed independence, and is generalizable to multiple dimensions. In brief, weighting functions are divided into regions of equal probability, which define the samples to be acquired. Quantile scheduling therefore achieves close adherence to a probability distribution function, thereby minimizing gaps for any given degree of subsampling of the Nyquist grid. A characteristic of quantile scheduling is that one-dimensional, weighted NUS schedules are deterministic, however higher dimensional schedules are similar within a user-specified jittering parameter. To develop unweighted sampling, we investigated the minimum jitter needed to disrupt subharmonic tracts, and show that this criterion can be met in many cases by jittering within 25-50% of the subharmonic gap. For nD-NUS, three supplemental components to choosing samples by quantiles are proposed in this work: (i) forcing the corner samples to ensure sampling to specified maximum values in indirect evolution times, (ii) providing an option to triangular backfill sampling schedules to promote dense/uniform tracts at the beginning of signal evolution periods, and (iii) providing an option to force the edges of nD-NUS schedules to be identical to the 1D quantiles. Quantile-directed scheduling meets the diverse needs of current NUS experimentation, but can also be used for future NUS implementations such as off-grid NUS and more. A computer program implementing these principles (a.k.a. QSched) in 1D- and 2D-NUS is available under the general public license.

  13. Rare behavior of growth processes via umbrella sampling of trajectories

    Science.gov (United States)

    Klymko, Katherine; Geissler, Phillip L.; Garrahan, Juan P.; Whitelam, Stephen

    2018-03-01

    We compute probability distributions of trajectory observables for reversible and irreversible growth processes. These results reveal a correspondence between reversible and irreversible processes, at particular points in parameter space, in terms of their typical and atypical trajectories. Thus key features of growth processes can be insensitive to the precise form of the rate constants used to generate them, recalling the insensitivity to microscopic details of certain equilibrium behavior. We obtained these results using a sampling method, inspired by the "s -ensemble" large-deviation formalism, that amounts to umbrella sampling in trajectory space. The method is a simple variant of existing approaches, and applies to ensembles of trajectories controlled by the total number of events. It can be used to determine large-deviation rate functions for trajectory observables in or out of equilibrium.

  14. Quantitative analysis of untreated bio-samples

    International Nuclear Information System (INIS)

    Sera, K.; Futatsugawa, S.; Matsuda, K.

    1999-01-01

    A standard-free method of quantitative analysis for untreated samples has been developed. For hair samples, measurements were performed by irradiating with a proton beam a few hairs as they are, and quantitative analysis was carried out by means of a standard-free method developed by ourselves. First, quantitative values of concentration of zinc were derived, then concentration of other elements was obtained by regarding zinc as an internal standard. As the result, values of concentration of sulphur for 40 samples agree well with the average value for a typical Japanese and also with each other within 20%, and validity of the present method could be confirmed. Accuracy was confirmed by comparing the results with those obtained by the usual internal standard method, too. For the purpose of a surface analysis of a bone sample, a very small incidence angle of the proton beam was used, so that both energy loss of the projectile and self-absorption of X-rays become negligible. As the result, consistent values of concentration for many elements were obtained by the standard-free method

  15. Survivability of Existing Peripheral Intravenous Access Following Blood Sampling in a Pediatric Population.

    Science.gov (United States)

    O'Neil, Sheree W; Friesen, Mary Ann; Stanger, Debra; Trickey, Amber Williams

    2018-03-07

    Although pediatric patients report venipuncture as their most feared experience during hospitalization, blood sampling from peripheral intravenous accesses (PIVs) is not standard of care. Blood sampling from PIVs has long been considered by healthcare personnel to harm the access. In an effort to minimize painful procedures, pediatric nursing staff conducted a prospective, observational study to determine if blood sampling using existing PIVs resulted in the loss of the access. The ability to obtain the sample from the PIV was measured along with patient and PIV characteristics. Specimen collection using 100 existing PIVs was attempted on pediatric inpatients. Each PIV was observed for functionality, infiltration, occlusion, and dislodgement following collection and again in 4h. Frequencies of PIV loss and successful blood sampling were calculated. Patient age, PIV gauge, access site, and PIV age were evaluated for associations with successful sampling using chi-square tests, Fisher's exact tests, and logistic regression. PIV survivability was reported at 99%. The ability to obtain a complete specimen was reported at 76% and found to be significantly related to PIV age and site. Size of PIV and patient's age were not significantly related to successful sampling. Encouraging rates of PIV survivability and collectability suggest blood sampling from PIVs to be a valuable technique to minimize painful and distressful procedures. Nursing practice was changed in this pediatric department. Patients and families are saved the pain and distress of venipuncture. Nurses reported saving time and personal distress by avoiding the venipuncture procedure. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    International Nuclear Information System (INIS)

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung; Parkhurst, MaryAnn; Hoover, Mark D.

    2009-01-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol

  17. Osteoinductive activity of insulin-functionalized cell culture surfaces obtained using diazonium chemistry

    Science.gov (United States)

    Mikulska, Anna; Filipowska, Joanna; Osyczka, Anna; Nowakowska, Maria; Szczubiałka, Krzysztof

    2014-12-01

    Polymeric surfaces suitable for cell culture (DR/Pec) were constructed from diazoresin (DR) and pectin (Pec) in a form of ultrathin films using the layer-by-layer (LbL) technique. The surfaces were functionalized with insulin using diazonium chemistry. Such functionalized surfaces were used to culture human mesenchymal stem cells (hMSCs) to assess their suitability for bone tissue engineering and regeneration. The activity of insulin immobilized on the surfaces (DR/Pec/Ins) was compared to that of insulin dissolved in the culture medium. Human MSC grown on insulin-immobilized DR/Pec surfaces displayed increased proliferation and higher osteogenic activity. The latter was determined by means of alkaline phosphatase (ALP) activity, which increases at early stages of osteoblasts differentiation. Insulin dissolved in the culture medium did not stimulate cell proliferation and its osteogenic activity was significantly lower. Addition of recombinant human bone morphogenetic protein 2 (rhBMP-2) to the culture medium further increased ALP activity in hMSCs indicating additive osteogenic action of immobilized insulin and rhBMP-2

  18. Osteoinductive activity of insulin-functionalized cell culture surfaces obtained using diazonium chemistry

    Directory of Open Access Journals (Sweden)

    Anna eMikulska

    2015-01-01

    Full Text Available Polymeric surfaces suitable for cell culture (DR/Pec were constructed from diazoresin (DR and pectin (Pec in a form of ultrathin films using the layer-by-layer (LbL technique. The surfaces were functionalized with insulin using diazonium chemistry. Such functionalized surfaces were used to culture human mesenchymal stem cells (hMSCs to assess their suitability for bone tissue engineering and regeneration. The activity of insulin immobilized on the surfaces (DR/Pec/Ins was compared to that of insulin dissolved in the culture medium. Human MSC grown on insulin-immobilized DR/Pec surfaces displayed increased proliferation and higher osteogenic activity. The latter was determined by means of alkaline phosphatase (ALP activity, which increases at early stages of osteoblasts differentiation. Insulin dissolved in the culture medium did not stimulate cell proliferation and its osteogenic activity was significantly lower. Addition of recombinant human bone morphogenetic protein 2 (rhBMP-2 to the culture medium further increased ALP activity in hMSCs indicating additive osteogenic action of immobilized insulin and rhBMP-2

  19. Probabilistic Q-function distributions in fermionic phase-space

    International Nuclear Information System (INIS)

    Rosales-Zárate, Laura E C; Drummond, P D

    2015-01-01

    We obtain a positive probability distribution or Q-function for an arbitrary fermionic many-body system. This is different to previous Q-function proposals, which were either restricted to a subspace of the overall Hilbert space, or used Grassmann methods that do not give probabilities. The fermionic Q-function obtained here is constructed using normally ordered Gaussian operators, which include both non-interacting thermal density matrices and BCS states. We prove that the Q-function exists for any density matrix, is real and positive, and has moments that correspond to Fermi operator moments. It is defined on a finite symmetric phase-space equivalent to the space of real, antisymmetric matrices. This has the natural SO(2M) symmetry expected for Majorana fermion operators. We show that there is a physical interpretation of the Q-function: it is the relative probability for observing a given Gaussian density matrix. The distribution has a uniform probability across the space at infinite temperature, while for pure states it has a maximum value on the phase-space boundary. The advantage of probabilistic representations is that they can be used for computational sampling without a sign problem. (fast track communication)

  20. Two sampling techniques for game meat

    Directory of Open Access Journals (Sweden)

    Maretha van der Merwe

    2013-03-01

    Full Text Available A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g and square centimetres (cm2 for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12 that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13 and analyses performed for aerobic plate count (APC, Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  1. Two sampling techniques for game meat.

    Science.gov (United States)

    van der Merwe, Maretha; Jooste, Piet J; Hoffman, Louw C; Calitz, Frikkie J

    2013-03-20

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13) and analyses performed for aerobic plate count (APC), Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  2. Electronic diffraction tomography by Green's functions and singular values decompositions

    International Nuclear Information System (INIS)

    Mayer, A.

    2001-01-01

    An inverse scattering technique is developed to enable a three-dimensional sample reconstruction from the diffraction figures obtained for different sample orientations by electronic projection microscopy, thus performing a diffraction tomography. In its Green's-functions formulation, this technique takes account of all orders of diffraction by performing an iterative reconstruction of the wave function on the observation screen and in the sample. In a final step, these quantities enable a reconstruction of the potential-energy distribution, which is assumed real valued. The method relies on the use of singular values decomposition techniques, thus providing the best least-squares solutions and enabling a reduction of noise. The technique is applied to the analysis of a three-dimensional nanometric sample that is observed in Fresnel conditions with an electron energy of 40 eV. The algorithm turns out to provide results with a mean relative error around 3% and to be stable against random noise

  3. Combination syringe provides air-free blood samples

    Science.gov (United States)

    Pool, S. L.

    1970-01-01

    Standard syringe and spinal needle are combined in unique manner to secure air-free blood samples. Combination syringe obtains air free samples because air bubbles become insignificant when samples greater than 1 cc are drawn.

  4. Core sampling system spare parts assessment

    International Nuclear Information System (INIS)

    Walter, E.J.

    1995-01-01

    Soon, there will be 4 independent core sampling systems obtaining samples from the underground tanks. It is desirable that these systems be available for sampling during the next 2 years. This assessment was prepared to evaluate the adequacy of the spare parts identified for the core sampling system and to provide recommendations that may remediate overages or inadequacies of spare parts

  5. Development of Input Function Measurement System for Small Animal PET Study

    International Nuclear Information System (INIS)

    Kim, Jong Guk; Kim, Byung Su; Kim, Jin Su

    2010-01-01

    For quantitative measurement of radioactivity concentration in tissue and a validated tracer kinetic model, the high sensitive detection system has been required for blood sampling. With the accurate measurement of time activity curves (TACs) of labeled compounds in blood (plasma) enable to provide quantitative information on biological parameters of interest in local tissue. Especially, the development of new tracers for PET imaging requires knowledge of the kinetics of the tracer in the body and in arterial blood and plasma. Conventional approaches of obtaining an input function are to sample arterial blood sequentially by manual as a function of time. Several continuous blood sampling systems have been developed and used in nuclear medicine research field to overcome the limited temporal resolution in sampling by the conventional method. In this work, we developed the high sensitive and unique geometric design of GSO detector for small animal blood activity measurement

  6. Determination of Contamination Profiles of Human Bacterial Pathogens in Shrimp Obtained from Java, Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Dewanti-Hariyadi, R. [Center for Assessment of Traditional Foods, Department of Food Technology and Human Nutrition, Bogor Agricultural University (Indonesia); Suliantari,; Nuraida, L. [Department of Food Technology and Human Nutrition, Faculty of Agricultural Technology, Bogor Agricultural University (Indonesia); Fardiaz, S. [Inter University for Food and Nutrition, Bogor Agricultural University, Bogor (Indonesia)

    2005-01-15

    Shrimp continues to be an important export commodity for Indonesia and contributed significantly to the country’s revenue. However, shrimp exports have been frequently rejected by importing countries due to filth, Salmonella and insanitary conditions. This study was conducted to evaluate the profiles of bacterial contamination of ocean and aquaculture shrimp obtained from the area of West, Central and East Java; frozen shrimp and shrimp during industry production of frozen shrimp. The study indicated that both ocean and aquaculture shrimp obtained from the study area were heavily contaminated. On the average, shrimp obtained from West Java were more contaminated than those obtained from East and Central Java. The total bacterial counts were generally higher in ocean shrimp than those of aquaculture ones. Salmonella was present in two of 32 samples of ocean shrimp and in four of 32 samples of aquaculture shrimp obtained from the study area. Vibrio cholerae was not detected in shrimp from West Java, but was found in three out of 16 samples obtained from East and Central Java. V. parahaemolyticus was frequently identified in aquaculture shrimp but absent in fresh ocean shrimp. Studies on shrimp collected from six sampling points during frozen shrimp production revealed that processing will reduce the number of total bacterial, E. coli, and Staphylococal counts. However, the processing did not effectively reduce the incidence of Salmonella or V. parahaemolyticus when the raw material has been contaminated with the pathogens. Sizing and grading as well as arrangement of shrimp before freezing were considered as the critical points where bacteria should be controlled to inhibit growth and cross contamination with bacteria such as Listeria. Implementation of Good Agricultural Practices in production of raw shrimp as well as Hazard Analysis Critical Control Point at the line processing are expected to improve the quality of fresh and frozen shrimp. (author)

  7. Multielement analysis of aerosol samples by X-ray fluorescence analysis with totally reflecting sample holders

    International Nuclear Information System (INIS)

    Ketelsen, P.; Knoechel, A.

    1984-01-01

    Aerosole samples on filter support were analyzed using the X-ray flourescence analytical method (Mo excitation) with totally reflecting sample carrier (TXFA). Wet decomposition of the sample material with HNO 3 in an enclosed system and subsequent sample preparation by evaporating an aliquot of the solution on the sample carrier yields detection limits up to 0.3 ng/cm 2 . The reproducibilities of the measurements of the elements K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb lie between 5 and 25%. Similar detection limits and reproducibilities are obtained, when low-temperature oxygen plasma is employed for the direct ashing of the homogenously covered filter on the sample carrier. For the systematic loss of elements both methods were investigated with radiotracers as well as with inactive techniques. A comparison of the results with those obtained by NAA, AAS and PIXE shows good agreement in most cases. For the bromine determination and the fast coverage of the main elements a possibility for measuring the filter membrane has been indicated, which neglects the ashing step. The corresponding detection limits are up to 3 ng/cm 2 . (orig.) [de

  8. Unbiased Sampling and Meshing of Isosurfaces

    KAUST Repository

    Yan, Dongming

    2014-05-07

    In this paper, we present a new technique to generate unbiased samples on isosurfaces. An isosurface, F(x,y,z) = c , of a function, F , is implicitly defined by trilinear interpolation of background grid points. The key idea of our approach is that of treating the isosurface within a grid cell as a graph (height) function in one of the three coordinate axis directions, restricted to where the slope is not too high, and integrating / sampling from each of these three. We use this unbiased sampling algorithm for applications in Monte Carlo integration, Poisson-disk sampling, and isosurface meshing.

  9. Unbiased Sampling and Meshing of Isosurfaces

    KAUST Repository

    Yan, Dongming; Wallner, Johannes; Wonka, Peter

    2014-01-01

    In this paper, we present a new technique to generate unbiased samples on isosurfaces. An isosurface, F(x,y,z) = c , of a function, F , is implicitly defined by trilinear interpolation of background grid points. The key idea of our approach is that of treating the isosurface within a grid cell as a graph (height) function in one of the three coordinate axis directions, restricted to where the slope is not too high, and integrating / sampling from each of these three. We use this unbiased sampling algorithm for applications in Monte Carlo integration, Poisson-disk sampling, and isosurface meshing.

  10. Sample to moderator volume ratio effects in neutron yield from a PGNAA setup

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Fazal-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia); Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia); Khateeb-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia)

    2007-02-15

    Performance of a prompt gamma ray neutron activation analysis (PGNAA) setup depends upon thermal neutron yield at the PGNAA sample location. For a moderator, which encloses a sample, thermal neutron intensity depends upon the effective moderator volume excluding the void volume due to sample volume. A rectangular moderator assembly has been designed for the King Fahd University of Petroleum and Minerals (KFUPM) PGNAA setup. The thermal and fast neutron yield has been measured inside the sample cavity as a function of its front moderator thickness using alpha particle tracks density and recoil proton track density inside the CR-39 nuclear track detectors (NTDs). The thermal/fast neutron yield ratio, obtained from the alpha particle tracks density to proton tracks density ratio in the NTDs, shows an inverse correlation with sample to moderator volume ratio. Comparison of the present results with the previously published results of smaller moderators of the KFUPM PGNAA setup confirms the observation.

  11. Statistical Analysis Of Tank 19F Floor Sample Results

    International Nuclear Information System (INIS)

    Harris, S.

    2010-01-01

    Representative sampling has been completed for characterization of the residual material on the floor of Tank 19F as per the statistical sampling plan developed by Harris and Shine. Samples from eight locations have been obtained from the tank floor and two of the samples were archived as a contingency. Six samples, referred to in this report as the current scrape samples, have been submitted to and analyzed by SRNL. This report contains the statistical analysis of the floor sample analytical results to determine if further data are needed to reduce uncertainty. Included are comparisons with the prior Mantis samples results to determine if they can be pooled with the current scrape samples to estimate the upper 95% confidence limits (UCL95%) for concentration. Statistical analysis revealed that the Mantis and current scrape sample results are not compatible. Therefore, the Mantis sample results were not used to support the quantification of analytes in the residual material. Significant spatial variability among the current scrape sample results was not found. Constituent concentrations were similar between the North and South hemispheres as well as between the inner and outer regions of the tank floor. The current scrape sample results from all six samples fall within their 3-sigma limits. In view of the results from numerous statistical tests, the data were pooled from all six current scrape samples. As such, an adequate sample size was provided for quantification of the residual material on the floor of Tank 19F. The uncertainty is quantified in this report by an UCL95% on each analyte concentration. The uncertainty in analyte concentration was calculated as a function of the number of samples, the average, and the standard deviation of the analytical results. The UCL95% was based entirely on the six current scrape sample results (each averaged across three analytical determinations).

  12. Sex assessment from carpals bones: discriminant function analysis in a contemporary Mexican sample.

    Science.gov (United States)

    Mastrangelo, Paola; De Luca, Stefano; Sánchez-Mejorada, Gabriela

    2011-06-15

    Sex assessment is one of the first essential steps in human identification, in both medico-legal cases and bio-archaeological contexts. Fragmentary human remains compromised by different types of burial or physical insults may frustrate the use of the traditional sex estimation methods, such as the analysis of the skull and pelvis. Currently, the application of discriminant functions to sex unidentified skeletal remains is steadily increasing. However, several studies have demonstrated that, due to variation in size and patterns of sexual dimorphism, discriminant functions are population-specific. In this study, in order to improve sex assessment from skeletal remains and to establish population-specific discriminant functions, the diagnostic values of the carpal bones were considered. A sample of 136 individuals (78 males, 58 females) of known sex and age was analyzed. They belong to a contemporary identified collection from the Laboratory of Physical Anthropology, Faculty of Medicine, UNAM (Universidad Nacional Autónoma de México, Mexico City). The age of the individuals ranged between 25 and 85 years. Between four and nine measurements of each carpal bone were taken. Independent t-tests confirm that all carpals are sexually dimorphic. Univariate measurements produce accuracy levels that range from 61.8% to 90.8%. Classification accuracies ranged between 81.3% and 92.3% in the multivariate stepwise discriminant analysis. In addition, intra- and inter-observer error tests were performed. These indicated that replication of measurements was satisfactory for the same observer over time and between observers. These results suggest that carpal bones can be used for assessing sex in both forensic and bio-archaeological identification procedures and that bone dimensions are population specific. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Frequency Response of the Sample Vibration Mode in Scanning Probe Acoustic Microscope

    International Nuclear Information System (INIS)

    Ya-Jun, Zhao; Qian, Cheng; Meng-Lu, Qian

    2010-01-01

    Based on the interaction mechanism between tip and sample in the contact mode of a scanning probe acoustic microscope (SPAM), an active mass of the sample is introduced in the mass-spring model. The tip motion and frequency response of the sample vibration mode in the SPAM are calculated by the Lagrange equation with dissipation function. For the silicon tip and glass assemblage in the SPAM the frequency response is simulated and it is in agreement with the experimental result. The living myoblast cells on the glass slide are imaged at resonance frequencies of the SPAM system, which are 20kHz, 30kHz and 120kHz. It is shown that good contrast of SPAM images could be obtained when the system is operated at the resonance frequencies of the system in high and low-frequency regions

  14. Evaluation of pump pulsation in respirable size-selective sampling: part II. Changes in sampling efficiency.

    Science.gov (United States)

    Lee, Eun Gyung; Lee, Taekhee; Kim, Seung Won; Lee, Larry; Flemmer, Michael M; Harper, Martin

    2014-01-01

    This second, and concluding, part of this study evaluated changes in sampling efficiency of respirable size-selective samplers due to air pulsations generated by the selected personal sampling pumps characterized in Part I (Lee E, Lee L, Möhlmann C et al. Evaluation of pump pulsation in respirable size-selective sampling: Part I. Pulsation measurements. Ann Occup Hyg 2013). Nine particle sizes of monodisperse ammonium fluorescein (from 1 to 9 μm mass median aerodynamic diameter) were generated individually by a vibrating orifice aerosol generator from dilute solutions of fluorescein in aqueous ammonia and then injected into an environmental chamber. To collect these particles, 10-mm nylon cyclones, also known as Dorr-Oliver (DO) cyclones, were used with five medium volumetric flow rate pumps. Those were the Apex IS, HFS513, GilAir5, Elite5, and Basic5 pumps, which were found in Part I to generate pulsations of 5% (the lowest), 25%, 30%, 56%, and 70% (the highest), respectively. GK2.69 cyclones were used with the Legacy [pump pulsation (PP) = 15%] and Elite12 (PP = 41%) pumps for collection at high flows. The DO cyclone was also used to evaluate changes in sampling efficiency due to pulse shape. The HFS513 pump, which generates a more complex pulse shape, was compared to a single sine wave fluctuation generated by a piston. The luminescent intensity of the fluorescein extracted from each sample was measured with a luminescence spectrometer. Sampling efficiencies were obtained by dividing the intensity of the fluorescein extracted from the filter placed in a cyclone with the intensity obtained from the filter used with a sharp-edged reference sampler. Then, sampling efficiency curves were generated using a sigmoid function with three parameters and each sampling efficiency curve was compared to that of the reference cyclone by constructing bias maps. In general, no change in sampling efficiency (bias under ±10%) was observed until pulsations exceeded 25% for the

  15. Sensitivity analysis using contribution to sample variance plot: Application to a water hammer model

    International Nuclear Information System (INIS)

    Tarantola, S.; Kopustinskas, V.; Bolado-Lavin, R.; Kaliatka, A.; Ušpuras, E.; Vaišnoras, M.

    2012-01-01

    This paper presents “contribution to sample variance plot”, a natural extension of the “contribution to the sample mean plot”, which is a graphical tool for global sensitivity analysis originally proposed by Sinclair. These graphical tools have a great potential to display graphically sensitivity information given a generic input sample and its related model realizations. The contribution to the sample variance can be obtained at no extra computational cost, i.e. from the same points used for deriving the contribution to the sample mean and/or scatter-plots. The proposed approach effectively instructs the analyst on how to achieve a targeted reduction of the variance, by operating on the extremes of the input parameters' ranges. The approach is tested against a known benchmark for sensitivity studies, the Ishigami test function, and a numerical model simulating the behaviour of a water hammer effect in a piping system.

  16. Sample Reuse in Statistical Remodeling.

    Science.gov (United States)

    1987-08-01

    as the jackknife and bootstrap, is an expansion of the functional, T(Fn), or of its distribution function or both. Frangos and Schucany (1987a) used...accelerated bootstrap. In the same report Frangos and Schucany demonstrated the small sample superiority of that approach over the proposals that take...higher order terms of an Edgeworth expansion into account. In a second report Frangos and Schucany (1987b) examined the small sample performance of

  17. 7 CFR 42.141 - Obtaining Operating Characteristic (OC) curve information for skip lot sampling and inspection.

    Science.gov (United States)

    2010-01-01

    ... Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices... sampling plan for normal condition of container inspection from Table I or Table I-A of § 42.109. (b) For a... procedures. For example, let's assume the lot size is 6,001 to 12,000 containers, and we use the single...

  18. Analysis of ADU structure obtained under different precipitation conditions

    International Nuclear Information System (INIS)

    Ramella, Jose L.; Esteban, Adolfo; Mendez De Leo, Lucia P.; Sassone, Ariel; Novara, Oscar E.; Boero, Norma L.; Leyva, Ana G.

    1999-01-01

    ADU is the nominal name for ammonium poly uranate. It is a very complex compound of polymeric structure, which may have, according to precipitation conditions, different chemical composition and crystallographic structure. ADU is used as uranium oxide precursor in the manufacture of fuel elements. In former papers it was proved that if ultrasound is applied during precipitation and digestion the characteristics of the final product (U 3 O 8 UO 2 ) improve. By studying ADU thermal decomposition obtained by ultrasonic application, it was intended to obtain its composition. Therefore, differential thermal gravimetric and differential thermal analyses were performed. Samples were taken from special points and analyzed by X-ray diffraction, infra-red spectroscopy and scanning. An experiment was also designed to identify the products released during heating. Results and conclusions obtained are presented in this work. (author)

  19. Sampling of systematic errors to estimate likelihood weights in nuclear data uncertainty propagation

    International Nuclear Information System (INIS)

    Helgesson, P.; Sjöstrand, H.; Koning, A.J.; Rydén, J.; Rochman, D.; Alhassan, E.; Pomp, S.

    2016-01-01

    In methodologies for nuclear data (ND) uncertainty assessment and propagation based on random sampling, likelihood weights can be used to infer experimental information into the distributions for the ND. As the included number of correlated experimental points grows large, the computational time for the matrix inversion involved in obtaining the likelihood can become a practical problem. There are also other problems related to the conventional computation of the likelihood, e.g., the assumption that all experimental uncertainties are Gaussian. In this study, a way to estimate the likelihood which avoids matrix inversion is investigated; instead, the experimental correlations are included by sampling of systematic errors. It is shown that the model underlying the sampling methodology (using univariate normal distributions for random and systematic errors) implies a multivariate Gaussian for the experimental points (i.e., the conventional model). It is also shown that the likelihood estimates obtained through sampling of systematic errors approach the likelihood obtained with matrix inversion as the sample size for the systematic errors grows large. In studied practical cases, it is seen that the estimates for the likelihood weights converge impractically slowly with the sample size, compared to matrix inversion. The computational time is estimated to be greater than for matrix inversion in cases with more experimental points, too. Hence, the sampling of systematic errors has little potential to compete with matrix inversion in cases where the latter is applicable. Nevertheless, the underlying model and the likelihood estimates can be easier to intuitively interpret than the conventional model and the likelihood function involving the inverted covariance matrix. Therefore, this work can both have pedagogical value and be used to help motivating the conventional assumption of a multivariate Gaussian for experimental data. The sampling of systematic errors could also

  20. Inferring common cognitive mechanisms from brain blood-flow lateralisation data obtained with functional transcranial Doppler ultrasound.

    Directory of Open Access Journals (Sweden)

    Georg eMeyer

    2014-06-01

    Full Text Available Current neuroimaging techniques with high spatial resolution constrain participant motion so that many natural tasks cannot be carried out. The aim of this paper is to show how a time-locked correlation-analysis of cerebral blood flow velocity (CBFV lateralisation data, obtained with functional TransCranial Doppler (fTCD ultrasound, can be used to infer cerebral activation patterns across tasks. In a first experiment we demonstrate that the proposed analysis method results in data that are comparable with the standard Lateralisation Index (LI for within-task comparisons of CBFV patterns, recorded during cued word generation (CWG at two difficulty levels.In the main experiment we demonstrate that the proposed analysis method shows correlated blood-flow patterns for two different cognitive tasks that are known to draw on common brain areas, CWG and Music Synthesis. We show that CBFV patterns for Music and CWG are correlated only for participants with prior musical training.CBFV patterns for tasks that draw on distinct brain areas, the Tower of London and CWG, are not correlated.The proposed methodology extends conventional fTCD analysis by including temporal information in the analysis of cerebral blood-flow patterns to provide a robust, non-invasive method to infer whether common brain areas are used in different cognitive tasks. It complements conventional high resolution imaging techniques.

  1. Sensitive determination of polycyclic aromatic hydrocarbons in water samples by HPLC coupled with SPE based on graphene functionalized with triethoxysilane.

    Science.gov (United States)

    Huang, Ke-Jing; Li, Jing; Liu, Yan-Ming; Wang, Lan

    2013-02-01

    The graphene functionalized with (3-aminopropyl) triethoxysilane was synthesized by a simple hydrothermal reaction and applied as SPE sorbents to extract trace polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. These sorbents possess high adsorption capacity and extraction efficiency due to strong adsorption ability of carbon materials and large specific surface area of nanoparticles, and only 10 mg of sorbents are required to extract PAHs from 100 mL water samples. Several condition parameters, such as eluent and its volume, adsorbent amount, sample volume, sample pH, and sample flow rate, were optimized to achieve good sensitivity and precision. Under the optimized extraction conditions, the method showed good linearity in the range of 1-100 μg/L, repeatability of the extraction (the RSDs were between 1.8 and 2.9%, n = 6), and satisfactory detection limits of 0.029-0.1 μg/L. The recoveries of PAHs spiked in environmental water samples ranged from 84.6 to 109.5%. All these results demonstrated that this new SPE technique was a viable alternative to conventional enrichment techniques for the extraction and analysis of PAHs in complex samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Hypersexual behavior in an online sample of males: associations with personal distress and functional impairment.

    Science.gov (United States)

    Spenhoff, Miriam; Kruger, Tillmann H C; Hartmann, Uwe; Kobs, Julia

    2013-12-01

    The population of individuals reporting hypersexual behavior is heterogeneous. Prior research has implicated the importance of personal distress and functional impairment, as both may serve as indicators of problem severity and relevance. Still, little is known about associations with distress and impairment following hypersexuality. The purpose of this study was to investigate personal distress and functional impairment in a community sample of male self-identified "sex addicts" and to explore the associations with related variables. Three hundred forty-nine men completed an online survey that included questions about personal distress, functional impairment, motivation for behavior change, type of hypersexual behaviors, time spent on sexual behavior, and progression of sexual urges. The survey included the Sexual Addiction Screening Test-Revised (SAST-R) core. Specific survey questions about personal distress and functional impairment in six life areas were used to assess these variables. Chi-square and P-values were calculated to explore the interrelations among them. There were 75.3% (N = 253) who reported feeling distressed due to hypersexual behavior. Functional impairment in at least one life area was specified by 77.4% (N = 270), and most participants (56.2%) reported impairment regarding partner relationships. Personal distress and functional impairment in three areas were associated with a strong motivation for behavior change. Distress was associated with online pornography use, masturbation, and/or sexual contact with changing partners. The progression of sexual urges was related to distress, while time spent on sexual behavior was not. There were 92.9% of the distressed participants who scored above the SAST-R core scale cut-off, but also 59.0% of the participants with little or no distress scored in this range. Results underline the particular role of problems in social or intimate relationships in association with hypersexuality. Clustering

  3. Physicochemical characteristics of ozonated sunflower oils obtained by different procedures

    Energy Technology Data Exchange (ETDEWEB)

    Diaz, M. F.; Sanchez, Y.; Gomez, M.; Hernandez, F.; Veloso, M. C.; Pereira, P. A.; Mangrich, A. S.; Andrade, J. B.

    2012-07-01

    Two ozonation procedures for sunflower oils at different applied ozone dosages were carried out. Ozone was obtained from medicinal oxygen and from air. Peroxide, acidity, and iodine indexes, along with density, viscosity and antimicrobial activity were determined. The fatty acid compositions of the samples were analyzed using GC. The content of oxygen was determined using an elemental analysis. Electronic Paramagnetic Resonance was used to measure the organic free radicals. The reactions were achieved up to peroxide index values of 658 and 675 mmolequiv kg1 using medicinal oxygen and air for 5 and 8 hours, respectively. The samples of ozonized sunflower oil did not present organic free radicals, which is a very important issue if these oils are to be used as drugs. The ozonation reaction is more rapid with medicinal oxygen (5 hours) than with air (8 hours). Ozonized sunflower oil with oxygen as an ozone source was obtained with high potential for antimicrobial activity. (Author) 34 refs.

  4. Lagoa Real design. Description and evaluation of sampling system

    International Nuclear Information System (INIS)

    Hashizume, B.K.

    1982-10-01

    This report describes the samples preparation system of drilling from Lagoa Real Design, aiming obtainment representative fraction of the half from drilling outlier. The error of sampling + analysis and analytical accuracy was obtainment by delayed neutron analysis. (author)

  5. Does the Social Functioning Scale reflect real-life social functioning? An experience sampling study in patients with a non-affective psychotic disorder and healthy control individuals.

    Science.gov (United States)

    Schneider, M; Reininghaus, U; van Nierop, M; Janssens, M; Myin-Germeys, I

    2017-12-01

    The ecological validity of retrospective measures of social functioning is currently unknown in patients with schizophrenia. In the present study, patients with a diagnosis of non-affective psychosis were compared with controls on two measures of social functioning: the Social Functioning Scale (SFS) and daily-life measures collected with the Experience Sampling Methodology (ESM). The associations between both measures were examined in each group of participants to test for the ecological validity of the SFS. A total of 126 participants with a non-affective psychotic disorder and 109 controls completed the SFS and a 6-day momentary ESM protocol assessing various aspects of social functioning. Multiple linear and multilevel regression analyses were performed to test for group differences in social functioning level and examine associations between the two assessment techniques. Lower social functioning was observed in patients compared with controls on retrospective and momentary measures. The SFS interpersonal domain (social engagement/withdrawal and interpersonal behaviour dimensions) was associated with the percentage of time spent alone and negative appraisal of social interactions. The SFS activity domain (pro-social and recreational activities dimensions) was negatively associated with time spent in leisure activities. The SFS showed some degree of ecological validity at assessing broad aspects of social functioning. Low scores on the SFS social engagement/withdrawal and interpersonal behaviour dimensions captured social isolation and social avoidance in daily life, but not lack of interest in socializing. Ecological validity of the SFS activity domain was low. ESM offers a rich alternative to classical assessment techniques of social functioning.

  6. Effect of sampling site, repeated sampling, pH, and PCO2 on plasma lactate concentration in healthy dogs.

    Science.gov (United States)

    Hughes, D; Rozanski, E R; Shofer, F S; Laster, L L; Drobatz, K J

    1999-04-01

    To characterize the variation in plasma lactate concentration among samples from commonly used blood sampling sites in conscious, healthy dogs. 60 healthy dogs. Cross-sectional study using a replicated Latin square design. Each dog was assigned to 1 of 6 groups (n = 10) representing all possible orders for 3 sites (cephalic vein, jugular vein, and femoral artery) used to obtain blood. Samples were analyzed immediately, by use of direct amperometry for pH, PO2, Pco2, glucose, and lactate concentration. Significant differences in plasma lactate concentrations were detected among blood samples from the cephalic vein (highest), femoral artery, and jugular vein (lowest). Mean plasma lactate concentration in the first sample obtained, irrespective of sampling site, was lower than in subsequent samples. Covariation was identified among plasma lactate concentration, pH, and PCO2, but correlation coefficients were low. Plasma lactate concentrations differed among blood samples from various sites. A reference range for plasma lactate concentration was 0.3 to 2.5 mmol/L. Differences in plasma lactate concentrations among samples from various sites and with repeated sampling, in healthy dogs, are small. Use of the reference range may facilitate the clinical use of plasma lactate concentration in dogs.

  7. Polythiophene films obtained by polymerization under atmospheric pressure plasma conditions

    Energy Technology Data Exchange (ETDEWEB)

    Teslaru, T.; Topala, I., E-mail: ionut.topala@uaic.ro; Dobromir, M.; Pohoata, V.; Curecheriu, L.; Dumitrascu, N.

    2016-02-01

    The present work describes the experimental arrangement used to initiate polymerization reactions of thiophene monomer based on a dielectric barrier discharge with plane – parallel geometry, working at atmospheric pressure in argon, in turn to obtain conductive polymeric films for different applications. The resulting plasma polymerized polythiophene (pPTh) film was characterized by FT-IR, UV–Vis, XPS spectroscopy, AFM and contact angle measurements. Characterization of pPTh films showed a higher hydrophobic character and roughness, as compared with films obtained by chemical methods, and the thickness is depending on polymerization duration. Also it can conclude that our samples represent oxidised state of pPTh. As a possible application, it analysed in situ the iodine absorption phenomenon in the pPTh matrix and its time evolution by UV–Vis spectroscopy. The presence of iodine 3d{sub 5/2} and 3d{sub 3/2} peaks in the pPTh sample after absorption was identified by XPS spectroscopy. The hydrophobic pPTh film is transformed in a super hydrophilic film after absorption of iodine vapors. - Highlights: • We obtained polythiophene films (pPTh) by atmospheric pressure plasma technique. • The pPTh films showed a hydrophobic character and conducting properties. • The pPTh films were used as sensor for iodine vapors in biological environment.

  8. Analysis of multiplex gene expression maps obtained by voxelation

    Directory of Open Access Journals (Sweden)

    Smith Desmond J

    2009-04-01

    Full Text Available Abstract Background Gene expression signatures in the mammalian brain hold the key to understanding neural development and neurological disease. Researchers have previously used voxelation in combination with microarrays for acquisition of genome-wide atlases of expression patterns in the mouse brain. On the other hand, some work has been performed on studying gene functions, without taking into account the location information of a gene's expression in a mouse brain. In this paper, we present an approach for identifying the relation between gene expression maps obtained by voxelation and gene functions. Results To analyze the dataset, we chose typical genes as queries and aimed at discovering similar gene groups. Gene similarity was determined by using the wavelet features extracted from the left and right hemispheres averaged gene expression maps, and by the Euclidean distance between each pair of feature vectors. We also performed a multiple clustering approach on the gene expression maps, combined with hierarchical clustering. Among each group of similar genes and clusters, the gene function similarity was measured by calculating the average gene function distances in the gene ontology structure. By applying our methodology to find similar genes to certain target genes we were able to improve our understanding of gene expression patterns and gene functions. By applying the clustering analysis method, we obtained significant clusters, which have both very similar gene expression maps and very similar gene functions respectively to their corresponding gene ontologies. The cellular component ontology resulted in prominent clusters expressed in cortex and corpus callosum. The molecular function ontology gave prominent clusters in cortex, corpus callosum and hypothalamus. The biological process ontology resulted in clusters in cortex, hypothalamus and choroid plexus. Clusters from all three ontologies combined were most prominently expressed in

  9. Analysis of multiplex gene expression maps obtained by voxelation.

    Science.gov (United States)

    An, Li; Xie, Hongbo; Chin, Mark H; Obradovic, Zoran; Smith, Desmond J; Megalooikonomou, Vasileios

    2009-04-29

    Gene expression signatures in the mammalian brain hold the key to understanding neural development and neurological disease. Researchers have previously used voxelation in combination with microarrays for acquisition of genome-wide atlases of expression patterns in the mouse brain. On the other hand, some work has been performed on studying gene functions, without taking into account the location information of a gene's expression in a mouse brain. In this paper, we present an approach for identifying the relation between gene expression maps obtained by voxelation and gene functions. To analyze the dataset, we chose typical genes as queries and aimed at discovering similar gene groups. Gene similarity was determined by using the wavelet features extracted from the left and right hemispheres averaged gene expression maps, and by the Euclidean distance between each pair of feature vectors. We also performed a multiple clustering approach on the gene expression maps, combined with hierarchical clustering. Among each group of similar genes and clusters, the gene function similarity was measured by calculating the average gene function distances in the gene ontology structure. By applying our methodology to find similar genes to certain target genes we were able to improve our understanding of gene expression patterns and gene functions. By applying the clustering analysis method, we obtained significant clusters, which have both very similar gene expression maps and very similar gene functions respectively to their corresponding gene ontologies. The cellular component ontology resulted in prominent clusters expressed in cortex and corpus callosum. The molecular function ontology gave prominent clusters in cortex, corpus callosum and hypothalamus. The biological process ontology resulted in clusters in cortex, hypothalamus and choroid plexus. Clusters from all three ontologies combined were most prominently expressed in cortex and corpus callosum. The experimental

  10. Determination of antioxidant activity of bioactive peptide fractions obtained from yogurt.

    Science.gov (United States)

    Aloğlu, H Sanlıdere; Oner, Z

    2011-11-01

    In this study, physicochemical and microbiological properties of traditional and commercial yogurt samples were determined during 4 wk of storage. Proteolytic activity, which occurs during the storage period of yogurt samples, was also determined. Peptide fractions obtained from yogurts were investigated and the effect of proteolysis on peptide release during storage was determined. The antioxidant activities of peptides released from yogurt water-soluble extracts (WSE) and from HPLC fractions were determined by 2,2'-azino-bis (3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) and 2,2-diphenyl-1-picrylhydrazyl (DPPH) methods. The antioxidant activity of WSE from traditional yogurt was greater than that of WSE from commercial yogurts. In analysis by the ABTS method, mean values increased from 7.697 to 8.739 mM Trolox/g in commercial yogurts, and from 10.115 to 13.182 mM Trolox/g in traditional yogurts during storage. Antioxidant activities of peptides released from HPLC fractions of selected yogurt samples increased 10 to 200 times. In all yogurt samples, the greatest antioxidant activity was shown in the F2 fraction. After further fractionation of yogurt samples, the fractions coded as F2.2, F2.3, F4.3, and F4.4 had the highest antioxidant activity values. Total antioxidant activity of yogurts was low but after purification of peptides by fractionation in HPLC, peptide fractions with high antioxidant activity were obtained. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. Improved sample size determination for attributes and variables sampling

    International Nuclear Information System (INIS)

    Stirpe, D.; Picard, R.R.

    1985-01-01

    Earlier INMM papers have addressed the attributes/variables problem and, under conservative/limiting approximations, have reported analytical solutions for the attributes and variables sample sizes. Through computer simulation of this problem, we have calculated attributes and variables sample sizes as a function of falsification, measurement uncertainties, and required detection probability without using approximations. Using realistic assumptions for uncertainty parameters of measurement, the simulation results support the conclusions: (1) previously used conservative approximations can be expensive because they lead to larger sample sizes than needed; and (2) the optimal verification strategy, as well as the falsification strategy, are highly dependent on the underlying uncertainty parameters of the measurement instruments. 1 ref., 3 figs

  12. Measurement of regional cerebral blood flow using one-point arterial blood sampling and microsphere model with 123I-IMP. Correction of one-point arterial sampling count by whole brain count ratio

    International Nuclear Information System (INIS)

    Makino, Kenichi; Masuda, Yasuhiko; Gotoh, Satoshi

    1998-01-01

    The experimental subjects were 189 patients with cerebrovascular disorders. 123 I-IMP, 222 MBq, was administered by intravenous infusion. Continuous arterial blood sampling was carried out for 5 minutes, and arterial blood was also sampled once at 5 minutes after 123 I-IMP administration. Then the whole blood count of the one-point arterial sampling was compared with the octanol-extracted count of the continuous arterial sampling. A positive correlation was found between the two values. The ratio of the continuous sampling octanol-extracted count (OC) to the one-point sampling whole blood count (TC5) was compared with the whole brain count ratio (5:29 ratio, Cn) using 1-minute planar SPECT images, centering on 5 and 29 minutes after 123 I-IMP administration. Correlation was found between the two values. The following relationship was shown from the correlation equation. OC/TC5=0.390969 x Cn-0.08924. Based on this correlation equation, we calculated the theoretical continuous arterial sampling octanol-extracted count (COC). COC=TC5 x (0.390969 x Cn-0.08924). There was good correlation between the value calculated with this equation and the actually measured value. The coefficient improved to r=0.94 from the r=0.87 obtained before using the 5:29 ratio for correction. For 23 of these 189 cases, another one-point arterial sampling was carried out at 6, 7, 8, 9 and 10 minutes after the administration of 123 I-IMP. The correlation coefficient was also improved for these other point samplings when this correction method using the 5:29 ratio was applied. It was concluded that it is possible to obtain highly accurate input functions, i.e., calculated continuous arterial sampling octanol-extracted counts, using one-point arterial sampling whole blood counts by performing correction using the 5:29 ratio. (K.H.)

  13. A Trivial Linear Discriminant Function

    Directory of Open Access Journals (Sweden)

    Shuichi Shinmura

    2015-11-01

    Full Text Available In this paper, we focus on the new model selection procedure of the discriminant analysis. Combining re-sampling technique with k-fold cross validation, we develop a k-fold cross validation for small sample method. By this breakthrough, we obtain the mean error rate in the validation samples (M2 and the 95\\% confidence interval (CI of discriminant coefficient. Moreover, we propose the model  selection  procedure  in  which  the model having a minimum M2 was  chosen  to  the  best  model.  We  apply  this  new  method and procedure to the pass/ fail determination of  exam  scores.  In  this  case,  we  fix  the constant =1 for seven linear discriminant  functions  (LDFs  and  several  good  results  were obtained as follows: 1 M2 of Fisher's LDF are over 4.6\\% worse than Revised IP-OLDF. 2 A soft-margin  SVM  for  penalty c=1  (SVM1  is  worse  than  another  mathematical  programming (MP based LDFs and logistic regression . 3 The 95\\% CI of the best discriminant coefficients was obtained. Seven LDFs except for Fisher's LDF are almost the same as a trivial LDF for the linear separable model. Furthermore, if we choose the median of the coefficient of seven LDFs except for Fisher's LDF,  those are almost the same as the trivial LDF for the linear separable model.

  14. A Differential Item Functional Analysis by Age of Perceived Interpersonal Discrimination in a Multi-racial/ethnic Sample of Adults.

    Science.gov (United States)

    Owens, Sherry; Kristjansson, Alfgeir L; Hunte, Haslyn E R

    2015-11-05

    We investigated whether individual items on the nine item William's Perceived Everyday Discrimination Scale (EDS) functioned differently by age (ethnic group. Overall, Asian and Hispanic respondents reported less discrimination than Whites; on the other hand, African Americans and Black Caribbeans reported more discrimination than Whites. Regardless of race/ethnicity, the younger respondents (aged ethnicity, the results were mixed for 19 out of 45 tests of DIF (40%). No differences in item function were observed among Black Caribbeans. "Being called names or insulted" and others acting as "if they are afraid" of the respondents were the only two items that did not exhibit differential item functioning by age across all racial/ethnic groups. Overall, our findings suggest that the EDS scale should be used with caution in multi-age multi-racial/ethnic samples.

  15. Microcomputer automation of the sample probe of an ESCA spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, J W; Downey, R M; Schrawyer, L R; Meisenheimer, R G [California Univ., Livermore (USA). Lawrence Livermore Lab.

    1979-06-01

    Many of the currently available ESCA spectrometers can be obtained with fully automated control and data acquisition systems as well as a variety of algorithms for data processing. The majority of these computer-controlled functions, however, are directed toward the analysis of a single physical sample. Since many analyses require the collection of data for several hours for the purpose of ensemble averaging to enhance the signal-to-noise ratio, overnight operation is a common practice. It is during these periods that a capability for multiple sample analyses would be most useful. The subject instrument for the automation was a Hewlett-Packard Model 5950A ESCA spectrometer which was supplied with a Hewlett-Packard 5952A Data System consisting of a Hewlett-Packard 2100A small computer and a Hewlett-Packard 85001A Magnetic Tape Cassett I/O unit. A microprocessor based system was used to implement this automation. The system uses the high-level language BASIC for virtually all control functions, thus providing the obvious advantages of rapid programming and ease of software modification over an assembly language although more ROM is required.

  16. Culturally appropriate methodology in obtaining a representative sample of South Australian Aboriginal adults for a cross-sectional population health study: challenges and resolutions.

    Science.gov (United States)

    Marin, Tania; Taylor, Anne Winifred; Grande, Eleonora Dal; Avery, Jodie; Tucker, Graeme; Morey, Kim

    2015-05-19

    The considerably lower average life expectancy of Aboriginal and Torres Strait Islander Australians, compared with non-Aboriginal and non-Torres Strait Islander Australians, has been widely reported. Prevalence data for chronic disease and health risk factors are needed to provide evidence based estimates for Australian Aboriginal and Torres Strait Islanders population health planning. Representative surveys for these populations are difficult due to complex methodology. The focus of this paper is to describe in detail the methodological challenges and resolutions of a representative South Australian Aboriginal population-based health survey. Using a stratified multi-stage sampling methodology based on the Australian Bureau of Statistics 2006 Census with culturally appropriate and epidemiological rigorous methods, 11,428 randomly selected dwellings were approached from a total of 209 census collection districts. All persons eligible for the survey identified as Aboriginal and/or Torres Strait Islander and were selected from dwellings identified as having one or more Aboriginal person(s) living there at the time of the survey. Overall, the 399 interviews from an eligible sample of 691 SA Aboriginal adults yielded a response rate of 57.7%. These face-to-face interviews were conducted by ten interviewers retained from a total of 27 trained Aboriginal interviewers. Challenges were found in three main areas: identification and recruitment of participants; interviewer recruitment and retainment; and using appropriate engagement with communities. These challenges were resolved, or at least mainly overcome, by following local protocols with communities and their representatives, and reaching agreement on the process of research for Aboriginal people. Obtaining a representative sample of Aboriginal participants in a culturally appropriate way was methodologically challenging and required high levels of commitment and resources. Adhering to these principles has resulted in a

  17. Low-sampling-rate ultra-wideband digital receiver using equivalent-time sampling

    KAUST Repository

    Ballal, Tarig

    2014-09-01

    In this paper, we propose an all-digital scheme for ultra-wideband symbol detection. In the proposed scheme, the received symbols are sampled many times below the Nyquist rate. It is shown that when the number of symbol repetitions, P, is co-prime with the symbol duration given in Nyquist samples, the receiver can sample the received data P times below the Nyquist rate, without loss of fidelity. The proposed scheme is applied to perform channel estimation and binary pulse position modulation (BPPM) detection. Results are presented for two receivers operating at two different sampling rates that are 10 and 20 times below the Nyquist rate. The feasibility of the proposed scheme is demonstrated in different scenarios, with reasonable bit error rates obtained in most of the cases.

  18. Low-sampling-rate ultra-wideband digital receiver using equivalent-time sampling

    KAUST Repository

    Ballal, Tarig; Al-Naffouri, Tareq Y.

    2014-01-01

    In this paper, we propose an all-digital scheme for ultra-wideband symbol detection. In the proposed scheme, the received symbols are sampled many times below the Nyquist rate. It is shown that when the number of symbol repetitions, P, is co-prime with the symbol duration given in Nyquist samples, the receiver can sample the received data P times below the Nyquist rate, without loss of fidelity. The proposed scheme is applied to perform channel estimation and binary pulse position modulation (BPPM) detection. Results are presented for two receivers operating at two different sampling rates that are 10 and 20 times below the Nyquist rate. The feasibility of the proposed scheme is demonstrated in different scenarios, with reasonable bit error rates obtained in most of the cases.

  19. Sample Selection for Training Cascade Detectors.

    Science.gov (United States)

    Vállez, Noelia; Deniz, Oscar; Bueno, Gloria

    2015-01-01

    Automatic detection systems usually require large and representative training datasets in order to obtain good detection and false positive rates. Training datasets are such that the positive set has few samples and/or the negative set should represent anything except the object of interest. In this respect, the negative set typically contains orders of magnitude more images than the positive set. However, imbalanced training databases lead to biased classifiers. In this paper, we focus our attention on a negative sample selection method to properly balance the training data for cascade detectors. The method is based on the selection of the most informative false positive samples generated in one stage to feed the next stage. The results show that the proposed cascade detector with sample selection obtains on average better partial AUC and smaller standard deviation than the other compared cascade detectors.

  20. Effects of statistical quality, sampling rate and temporal filtering techniques on the extraction of functional parameters from the left ventricular time-activity curves

    Energy Technology Data Exchange (ETDEWEB)

    Guignard, P.A.; Chan, W. (Royal Melbourne Hospital, Parkville (Australia). Dept. of Nuclear Medicine)

    1984-09-01

    Several techniques for the processing of a series of curves derived from two left ventricular time-activity curves acquired at rest and during exercise with a nuclear stethoscope were evaluated. They were three and five point time smoothing. Fourier filtering preserving one to four harmonics (H), truncated curve Fourier filtering, and third degree polynomial curve fitting. Each filter's ability to recover, with fidelity, systolic and diastolic function parameters was evaluated under increasingly 'noisy' conditions and at several sampling rates. Third degree polynomial curve fittings and truncated Fourier filters exhibited very high sensitivity to noise. Three and five point time smoothing had moderate sensitivity to noise, but were highly affected by sampling rate. Fourier filtering preserving 2H or 3H produced the best compromise with high resilience to noise and independence of sampling rate as far as the recovery of these functional parameters is concerned.

  1. Effects of statistical quality, sampling rate and temporal filtering techniques on the extraction of functional parameters from the left ventricular time-activity curves

    International Nuclear Information System (INIS)

    Guignard, P.A.; Chan, W.

    1984-01-01

    Several techniques for the processing of a series of curves derived from two left ventricular time-activity curves acquired at rest and during exercise with a nuclear stethoscope were evaluated. They were three and five point time smoothing. Fourier filtering preserving one to four harmonics (H), truncated curve Fourier filtering, and third degree polynomial curve fitting. Each filter's ability to recover, with fidelity, systolic and diastolic function parameters was evaluated under increasingly 'noisy' conditions and at several sampling rates. Third degree polynomial curve fittings and truncated Fourier filters exhibited very high sensitivity to noise. Three and five point time smoothing had moderate sensitivity to noise, but were highly affected by sampling rate. Fourier filtering preserving 2H or 3H produced the best compromise with high resilience to noise and independence of sampling rate as far as the recovery of these functional parameters is concerned. (author)

  2. 7 CFR 800.82 - Sampling provisions by level of service.

    Science.gov (United States)

    2010-01-01

    ... be performed on the basis of the sample as submitted. (b) Reinspection, and appeal inspection... requested. In performing these services, a sample obtained with an approved diverter-type mechanical sampler... criteria, and a sample obtained with a probe at the time of the reinspection or appeal, generally, shall be...

  3. A sampling-based Bayesian model for gas saturation estimationusing seismic AVA and marine CSEM data

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jinsong; Hoversten, Michael; Vasco, Don; Rubin, Yoram; Hou,Zhangshuan

    2006-04-04

    We develop a sampling-based Bayesian model to jointly invertseismic amplitude versus angles (AVA) and marine controlled-sourceelectromagnetic (CSEM) data for layered reservoir models. The porosityand fluid saturation in each layer of the reservoir, the seismic P- andS-wave velocity and density in the layers below and above the reservoir,and the electrical conductivity of the overburden are considered asrandom variables. Pre-stack seismic AVA data in a selected time windowand real and quadrature components of the recorded electrical field areconsidered as data. We use Markov chain Monte Carlo (MCMC) samplingmethods to obtain a large number of samples from the joint posteriordistribution function. Using those samples, we obtain not only estimatesof each unknown variable, but also its uncertainty information. Thedeveloped method is applied to both synthetic and field data to explorethe combined use of seismic AVA and EM data for gas saturationestimation. Results show that the developed method is effective for jointinversion, and the incorporation of CSEM data reduces uncertainty influid saturation estimation, when compared to results from inversion ofAVA data only.

  4. Device for sampling HTGR recycle fuel particles

    International Nuclear Information System (INIS)

    Suchomel, R.R.; Lackey, W.J.

    1977-03-01

    Devices for sampling High-Temperature Gas-Cooled Reactor fuel microspheres were evaluated. Analysis of samples obtained with each of two specially designed passive samplers were compared with data generated by more common techniques. A ten-stage two-way sampler was found to produce a representative sample with a constant batch-to-sample ratio

  5. The hardness of synthetic products obtained from cooled and crystallized basaltic melts (in Romanian

    Directory of Open Access Journals (Sweden)

    Daniela Ogrean

    2001-04-01

    Full Text Available The Hardness of Synthetic Products Obtained from Cooled and Crystallized Basaltic Melts. Hardness is one of the main properties of the products obtained from cooled and crystallized basaltic melts under a controlled thermal regime. It influences the abrasion tear resistance of the resulted material. The microhardness measurements on the samples (bricks, boards, gutters, armour plates, tubes indicated Vickers hardness value between 757–926 for the materials obtained from Şanovita basalts (Timiş district and between 539–958 respectively, in case of the Racoş basalts (Braşov district. There is a certain variation of the hardness within the same sample, in various measurement points, within the theoretical limits of the hardnesses of the pyroxenes and that of the spinels.

  6. Molecular analyses of two bacterial sampling methods in ligature-induced periodontitis in rats.

    Science.gov (United States)

    Fontana, Carla Raquel; Grecco, Clovis; Bagnato, Vanderlei Salvador; de Freitas, Laura Marise; Boussios, Constantinos I; Soukos, Nikolaos S

    2018-02-01

    The prevalence profile of periodontal pathogens in dental plaque can vary as a function of the detection method; however, the sampling technique may also play a role in determining dental plaque microbial profiles. We sought to determine the bacterial composition comparing two sampling methods, one well stablished and a new one proposed here. In this study, a ligature-induced periodontitis model was used in 30 rats. Twenty-seven days later, ligatures were removed and microbiological samples were obtained directly from the ligatures as well as from the periodontal pockets using absorbent paper points. Microbial analysis was performed using DNA probes to a panel of 40 periodontal species in the checkerboard assay. The bacterial composition patterns were similar for both sampling methods. However, detection levels for all species were markedly higher for ligatures compared with paper points. Ligature samples provided more bacterial counts than paper points, suggesting that the technique for induction of periodontitis could also be applied for sampling in rats. Our findings may be helpful in designing studies of induced periodontal disease-associated microbiota.

  7. Quantification of platelets obtained by different centrifugation protocols in SHR rats

    Directory of Open Access Journals (Sweden)

    João Alberto Yazigi Junior

    2015-12-01

    Full Text Available ABSTRACT OBJECTIVE: To quantify the platelet concentration in the blood of SHR rats, by means of different centrifugation protocols, and to evaluate what the most effective method for obtaining platelets is. METHODS: We used 40 male rats of the isogenic SHR lineage. The animals were divided into three groups: control, using whole blood without centrifugation; single centrifugation, using whole blood subjected to a single centrifugation at 200 × gand 400 × g; and double centrifugation, using whole blood subjected one centrifugation at different rotations, followed by collection of whole plasma subjected to another centrifugation at different rotations: 200 × g+ 200 ×g; 200 × g+ 400 × g; 200 × g+ 800 × g; 400 ×g+ 400 × g; 400 × g+ 800 × g. Samples of 3 ml of blood were drawn from each animal by means of cardiac puncture. The blood was stored in Vacutainer collection tubes containing 3.2% sodium citrate. The blood from the control group animals was analyzed without being subjected to centrifugation. After the blood from the other groups of animals had been subjected to centrifugation, the whole plasma was collected and subjected to platelet counting in the lower third of the sample. RESULTS: We obtained greatest platelet enrichment in the subgroup with two centrifugations comprising 400 × gfor 10 min + 400 ×gfor 10 min, in which the mean platelet concentration was 11.30 times higher than that of the control group. CONCLUSION: It was possible to obtain a high platelet concentration using viable simple techniques, by means of centrifugation of whole blood and use of commonly used materials. The most effective method for obtaining platelet concentrate was found in samples subjected to two centrifugations.

  8. Sampling marine sediments for radionuclide monitoring

    International Nuclear Information System (INIS)

    Papucci, C.

    1997-01-01

    A description of the most common devices used for sampling marine sediments are reported. The systems are compared to evidence their intrinsic usefulness, for collecting samples in different environmental conditions or with different scientific objectives. Perturbations and artifacts introduced during the various steps of the sampling procedure are also reviewed, and suggestions are proposed for obtaining and preserving, as much as possible, the representativeness of the sediment samples. (author)

  9. Hybrid algorithm of ensemble transform and importance sampling for assimilation of non-Gaussian observations

    Directory of Open Access Journals (Sweden)

    Shin'ya Nakano

    2014-05-01

    Full Text Available A hybrid algorithm that combines the ensemble transform Kalman filter (ETKF and the importance sampling approach is proposed. Since the ETKF assumes a linear Gaussian observation model, the estimate obtained by the ETKF can be biased in cases with nonlinear or non-Gaussian observations. The particle filter (PF is based on the importance sampling technique, and is applicable to problems with nonlinear or non-Gaussian observations. However, the PF usually requires an unrealistically large sample size in order to achieve a good estimation, and thus it is computationally prohibitive. In the proposed hybrid algorithm, we obtain a proposal distribution similar to the posterior distribution by using the ETKF. A large number of samples are then drawn from the proposal distribution, and these samples are weighted to approximate the posterior distribution according to the importance sampling principle. Since the importance sampling provides an estimate of the probability density function (PDF without assuming linearity or Gaussianity, we can resolve the bias due to the nonlinear or non-Gaussian observations. Finally, in the next forecast step, we reduce the sample size to achieve computational efficiency based on the Gaussian assumption, while we use a relatively large number of samples in the importance sampling in order to consider the non-Gaussian features of the posterior PDF. The use of the ETKF is also beneficial in terms of the computational simplicity of generating a number of random samples from the proposal distribution and in weighting each of the samples. The proposed algorithm is not necessarily effective in case that the ensemble is located distant from the true state. However, monitoring the effective sample size and tuning the factor for covariance inflation could resolve this problem. In this paper, the proposed hybrid algorithm is introduced and its performance is evaluated through experiments with non-Gaussian observations.

  10. Estimation of creatinine in Urine sample by Jaffe's method

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Arunkumar, Suja; Sawant, Pramilla D.; Rao, B.B.

    2012-01-01

    In-vitro bioassay monitoring is based on the determination of activity concentrations in biological samples excreted from the body and is most suitable for alpha and beta emitters. A truly representative bioassay sample is the one having all the voids collected during a 24-h period however, this being technically difficult, overnight urine samples collected by the workers are analyzed. These overnight urine samples are collected for 10-16 h, however in the absence of any specific information, 12 h duration is assumed and the observed results are then corrected accordingly obtain the daily excretion rate. To reduce the uncertainty due to unknown duration of sample collection, IAEA has recommended two methods viz., measurement of specific gravity and creatinine excretion rate in urine sample. Creatinine is a final metabolic product creatinine phosphate in the body and is excreted at a steady rate for people with normally functioning kidneys. It is, therefore, often used as a normalization factor for estimation of duration of sample collection. The present study reports the chemical procedure standardized and its application for the estimation of creatinine in urine samples collected from occupational workers. Chemical procedure for estimation of creatinine in bioassay samples was standardized and applied successfully for its estimation in bioassay samples collected from the workers. The creatinine excretion rate observed for these workers is lower than observed in literature. Further, work is in progress to generate a data bank of creatinine excretion rate for most of the workers and also to study the variability in creatinine coefficient for the same individual based on the analysis of samples collected for different duration

  11. Characterization of some etalon matrices obtained by cement conditioning of the radioactive sludge

    International Nuclear Information System (INIS)

    Nicu, M.; Mihai, F.

    1998-01-01

    The aim of this work was to establish new ways of investigation of some compounds which are important for studying physico-mechanical mechanisms, nature and structure of the intermediate and final products oc curing in reactions of the technological conditioning processes of the radioactive wastes by cementation after their treatment by precipitation or sorption process. Cement conditioning is, presently, the most used technology for the low and intermediate level waste treatment. Besides many advantages it also presents some disadvantages which limit the utilization area depending, firstly, on the chemical composition of the conditioned radioactive waste. In this work, the influence of different iron precipitates on cement structure is studied and assessed by changes in phase composition and mechanical resistance. Using mechanical resistance data, X-rays diffraction spectra and Moessbauer spectroscopy for iron precipitates and cement-iron precipitate samples, we obtained an image concerning chemical reactions and modifications which appear when iron precipitate is included in cement, between major components of cement and the added one. Moessbauer spectroscopy and X-rays diffraction were proved to be very useful to establish composition and structure of iron compounds used in treatment technology by chemical precipitation. Precipitation mechanism may be elucidated only by a thoroughgoing study of intermediate compounds obtained in successive precipitation phases. Depending on precipitation procedure, initial iron cations and order of adding of reactants, it was observed that the structure of finally obtained precipitates is different. Obtained results at compression tests on cement-iron precipitate samples are similarly with those obtained for reference cement matrix. These results demonstrate that iron precipitate in the sample with precipitate/cement ratio of 1/2 does not influence the mechanical resistance of the obtained matrix The presented results are in

  12. The Lunar Sample Compendium

    Science.gov (United States)

    Meyer, Charles

    2009-01-01

    The Lunar Sample Compendium is a succinct summary of the data obtained from 40 years of study of Apollo and Luna samples of the Moon. Basic petrographic, chemical and age information is compiled, sample-by-sample, in the form of an advanced catalog in order to provide a basic description of each sample. The LSC can be found online using Google. The initial allocation of lunar samples was done sparingly, because it was realized that scientific techniques would improve over the years and new questions would be formulated. The LSC is important because it enables scientists to select samples within the context of the work that has already been done and facilitates better review of proposed allocations. It also provides back up material for public displays, captures information found only in abstracts, grey literature and curatorial databases and serves as a ready access to the now-vast scientific literature.

  13. An Intrinsic Algorithm for Parallel Poisson Disk Sampling on Arbitrary Surfaces.

    Science.gov (United States)

    Ying, Xiang; Xin, Shi-Qing; Sun, Qian; He, Ying

    2013-03-08

    Poisson disk sampling plays an important role in a variety of visual computing, due to its useful statistical property in distribution and the absence of aliasing artifacts. While many effective techniques have been proposed to generate Poisson disk distribution in Euclidean space, relatively few work has been reported to the surface counterpart. This paper presents an intrinsic algorithm for parallel Poisson disk sampling on arbitrary surfaces. We propose a new technique for parallelizing the dart throwing. Rather than the conventional approaches that explicitly partition the spatial domain to generate the samples in parallel, our approach assigns each sample candidate a random and unique priority that is unbiased with regard to the distribution. Hence, multiple threads can process the candidates simultaneously and resolve conflicts by checking the given priority values. It is worth noting that our algorithm is accurate as the generated Poisson disks are uniformly and randomly distributed without bias. Our method is intrinsic in that all the computations are based on the intrinsic metric and are independent of the embedding space. This intrinsic feature allows us to generate Poisson disk distributions on arbitrary surfaces. Furthermore, by manipulating the spatially varying density function, we can obtain adaptive sampling easily.

  14. A comprehensive evaluation of potential lung function associated genes in the SpiroMeta general population sample.

    Directory of Open Access Journals (Sweden)

    Ma'en Obeidat

    Full Text Available Lung function measures are heritable traits that predict population morbidity and mortality and are essential for the diagnosis of chronic obstructive pulmonary disease (COPD. Variations in many genes have been reported to affect these traits, but attempts at replication have provided conflicting results. Recently, we undertook a meta-analysis of Genome Wide Association Study (GWAS results for lung function measures in 20,288 individuals from the general population (the SpiroMeta consortium.To comprehensively analyse previously reported genetic associations with lung function measures, and to investigate whether single nucleotide polymorphisms (SNPs in these genomic regions are associated with lung function in a large population sample.We analysed association for SNPs tagging 130 genes and 48 intergenic regions (+/-10 kb, after conducting a systematic review of the literature in the PubMed database for genetic association studies reporting lung function associations.The analysis included 16,936 genotyped and imputed SNPs. No loci showed overall significant association for FEV(1 or FEV(1/FVC traits using a carefully defined significance threshold of 1.3×10(-5. The most significant loci associated with FEV(1 include SNPs tagging MACROD2 (P = 6.81×10(-5, CNTN5 (P = 4.37×10(-4, and TRPV4 (P = 1.58×10(-3. Among ever-smokers, SERPINA1 showed the most significant association with FEV(1 (P = 8.41×10(-5, followed by PDE4D (P = 1.22×10(-4. The strongest association with FEV(1/FVC ratio was observed with ABCC1 (P = 4.38×10(-4, and ESR1 (P = 5.42×10(-4 among ever-smokers.Polymorphisms spanning previously associated lung function genes did not show strong evidence for association with lung function measures in the SpiroMeta consortium population. Common SERPINA1 polymorphisms may affect FEV(1 among smokers in the general population.

  15. Exploiting the functional and taxonomic structure of genomic data by probabilistic topic modeling.

    Science.gov (United States)

    Chen, Xin; Hu, Xiaohua; Lim, Tze Y; Shen, Xiajiong; Park, E K; Rosen, Gail L

    2012-01-01

    In this paper, we present a method that enable both homology-based approach and composition-based approach to further study the functional core (i.e., microbial core and gene core, correspondingly). In the proposed method, the identification of major functionality groups is achieved by generative topic modeling, which is able to extract useful information from unlabeled data. We first show that generative topic model can be used to model the taxon abundance information obtained by homology-based approach and study the microbial core. The model considers each sample as a “document,” which has a mixture of functional groups, while each functional group (also known as a “latent topic”) is a weight mixture of species. Therefore, estimating the generative topic model for taxon abundance data will uncover the distribution over latent functions (latent topic) in each sample. Second, we show that, generative topic model can also be used to study the genome-level composition of “N-mer” features (DNA subreads obtained by composition-based approaches). The model consider each genome as a mixture of latten genetic patterns (latent topics), while each functional pattern is a weighted mixture of the “N-mer” features, thus the existence of core genomes can be indicated by a set of common N-mer features. After studying the mutual information between latent topics and gene regions, we provide an explanation of the functional roles of uncovered latten genetic patterns. The experimental results demonstrate the effectiveness of proposed method.

  16. Factors Affecting Cognitive Function in Older Adults: A Turkish Sample

    OpenAIRE

    Akdag, Beyza; Telci, Emine Aslan; Cavlak, Ugur

    2013-01-01

    Background: The purpose of this study was to determine the influential factors of cognitive function in older adults. Methods: In this study, 377 older adults (mean age: 74.71 ± 6.15 years) were examined. The Hodkinson Abbreviated Mental Test (HAMT) was used to describe cognitive function of the individuals. The Centers for Disease Control (CDC) Health-Related Quality of Life (HRQOL-4) survey tool was used to measure the quality of life. Possible influential factors of cognitive function w...

  17. A Geology Sampling System for Small Bodies

    Science.gov (United States)

    Naids, Adam J.; Hood, Anthony D.; Abell, Paul; Graff, Trevor; Buffington, Jesse

    2016-01-01

    Human exploration of microgravity bodies is being investigated as a precursor to a Mars surface mission. Asteroids, comets, dwarf planets, and the moons of Mars all fall into this microgravity category and some are being discussed as potential mission targets. Obtaining geological samples for return to Earth will be a major objective for any mission to a small body. Currently, the knowledge base for geology sampling in microgravity is in its infancy. Humans interacting with non-engineered surfaces in microgravity environment pose unique challenges. In preparation for such missions a team at the NASA Johnson Space Center has been working to gain experience on how to safely obtain numerous sample types in such an environment. This paper describes the type of samples the science community is interested in, highlights notable prototype work, and discusses an integrated geology sampling solution.

  18. A Geology Sampling System for Microgravity Bodies

    Science.gov (United States)

    Hood, Anthony; Naids, Adam

    2016-01-01

    Human exploration of microgravity bodies is being investigated as a precursor to a Mars surface mission. Asteroids, comets, dwarf planets, and the moons of Mars all fall into this microgravity category and some are been discussed as potential mission targets. Obtaining geological samples for return to Earth will be a major objective for any mission to a microgravity body. Currently the knowledge base for geology sampling in microgravity is in its infancy. Humans interacting with non-engineered surfaces in microgravity environment pose unique challenges. In preparation for such missions a team at the NASA Johnson Space Center has been working to gain experience on how to safely obtain numerous sample types in such an environment. This paper describes the type of samples the science community is interested in, highlights notable prototype work, and discusses an integrated geology sampling solution.

  19. Altered Brain Functional Connectivity in Betel Quid-Dependent Chewers.

    Science.gov (United States)

    Huang, Xiaojun; Pu, Weidan; Liu, Haihong; Li, Xinmin; Greenshaw, Andrew J; Dursun, Serdar M; Xue, Zhimin; Liu, Zhening

    2017-01-01

    Betel quid (BQ) is a common psychoactive substance worldwide with particularly high usage in many Asian countries. This study aimed to explore the effect of BQ use on functional connectivity by comparing global functional brain networks and their subset between BQ chewers and healthy controls (HCs). Resting-state functional magnetic resonance imaging (fMRI) was obtained from 24 betel quid-dependent (BQD) male chewers and 27 healthy male individuals on a 3.0T scanner. We used independent component analysis (ICA) to determine components that represent the brain's functional networks and their spatial aspects of functional connectivity. Two sample t -tests were used to identify the functional connectivity differences in each network between these two groups. Seventeen networks were identified by ICA. Nine of them showed connectivity differences between BQD and HCs (two sample t -tests, p  betel quid dependence scale scores were positively related to the increased functional connectivity in the orbitofrontal ( r  = 0.39, p  = 0.03) while negatively related to the decreased functional connectivity in medial frontal/anterior cingulate networks ( r  = -0.35, p  = 0.02). Our findings provide further evidence that BQ chewing may lead to brain functional connectivity changes, which may play a key role in the psychological and physiological effects of BQ.

  20. Ventral Striatum Functional Connectivity as a Predictor of Adolescent Depressive Disorder in a Longitudinal Community-Based Sample.

    Science.gov (United States)

    Pan, Pedro Mario; Sato, João R; Salum, Giovanni A; Rohde, Luis A; Gadelha, Ary; Zugman, Andre; Mari, Jair; Jackowski, Andrea; Picon, Felipe; Miguel, Eurípedes C; Pine, Daniel S; Leibenluft, Ellen; Bressan, Rodrigo A; Stringaris, Argyris

    2017-11-01

    Previous studies have implicated aberrant reward processing in the pathogenesis of adolescent depression. However, no study has used functional connectivity within a distributed reward network, assessed using resting-state functional MRI (fMRI), to predict the onset of depression in adolescents. This study used reward network-based functional connectivity at baseline to predict depressive disorder at follow-up in a community sample of adolescents. A total of 637 children 6-12 years old underwent resting-state fMRI. Discovery and replication analyses tested intrinsic functional connectivity (iFC) among nodes of a putative reward network. Logistic regression tested whether striatal node strength, a measure of reward-related iFC, predicted onset of a depressive disorder at 3-year follow-up. Further analyses investigated the specificity of this prediction. Increased left ventral striatum node strength predicted increased risk for future depressive disorder (odds ratio=1.54, 95% CI=1.09-2.18), even after excluding participants who had depressive disorders at baseline (odds ratio=1.52, 95% CI=1.05-2.20). Among 11 reward-network nodes, only the left ventral striatum significantly predicted depression. Striatal node strength did not predict other common adolescent psychopathology, such as anxiety, attention deficit hyperactivity disorder, and substance use. Aberrant ventral striatum functional connectivity specifically predicts future risk for depressive disorder. This finding further emphasizes the need to understand how brain reward networks contribute to youth depression.