WorldWideScience

Sample records for sampling ets technique

  1. Elemental analyses of goundwater: demonstrated advantage of low-flow sampling and trace-metal clean techniques over standard techniques

    Science.gov (United States)

    Creasey, C. L.; Flegal, A. R.

    The combined use of both (1) low-flow purging and sampling and (2) trace-metal clean techniques provides more representative measurements of trace-element concentrations in groundwater than results derived with standard techniques. The use of low-flow purging and sampling provides relatively undisturbed groundwater samples that are more representative of in situ conditions, and the use of trace-element clean techniques limits the inadvertent introduction of contaminants during sampling, storage, and analysis. When these techniques are applied, resultant trace-element concentrations are likely to be markedly lower than results based on standard sampling techniques. In a comparison of data derived from contaminated and control groundwater wells at a site in California, USA, trace-element concentrations from this study were 2-1000 times lower than those determined by the conventional techniques used in sampling of the same wells prior to (5months) and subsequent to (1month) the collections for this study. Specifically, the cadmium and chromium concentrations derived using standard sampling techniques exceed the California Maximum Contaminant Levels (MCL), whereas in this investigation concentrations of both of those elements are substantially below their MCLs. Consequently, the combined use of low-flow and trace-metal clean techniques may preclude erroneous reports of trace-element contamination in groundwater. Résumé L'utilisation simultanée de la purge et de l'échantillonnage à faible débit et des techniques sans traces de métaux permet d'obtenir des mesures de concentrations en éléments en traces dans les eaux souterraines plus représentatives que les résultats fournis par les techniques classiques. L'utilisation de la purge et de l'échantillonnage à faible débit donne des échantillons d'eau souterraine relativement peu perturbés qui sont plus représentatifs des conditions in situ, et le recours aux techniques sans éléments en traces limite l

  2. Cartographie des zones d'intervention des partenaires techniques et ...

    African Journals Online (AJOL)

    cartographier les zones d'intervention des partenaires techniques et financiers au Bénin. L'approche méthodologique utilisée a consisté à la recherche documentaire, à la collecte de données auprès des partenaires techniques et financiers et à l'analyse de ces données. Les résultats ont permis de constater que cent dix ...

  3. normes techniques et pratiques locales des producteurs dans les ...

    African Journals Online (AJOL)

    ACSS

    pour objectif d'analyser l'évolution des normes techniques de la production du riz et les pratiques locales dans les périmètres .... des systèmes de production agricole et du riz dans les ..... recommandations de l'encadrement technique local.

  4. Techniques de formage et d'assemblage

    CERN Document Server

    Favre, G; CERN. Geneva. TS Department

    2004-01-01

    Les sections Techniques d'Assemblage du groupe EST/MF et Brasage du groupe EST/SM ont été groupées en un seul service dans un but de rationalisation accrue des ressources et méthodes. Ce service dispose de nombreux moyens : soudure et découpe LASER (YAG, 350 W), soudure par faisceau d'électrons (deux installations, 35 et 7.5 kW), équipements TIG orbital, jet line, MIG, soudure plasma, boîte à gants, portique de soudage trois axes multiprocédés, presses plieuses, rouleuses, moyens de repoussage, alimentation à induction 12 kW et divers fours sous vide et à air. Le service est composé de 17 personnes dont la polyvalence est encouragée. Les activités de la section seront décrites à travers quelques exemples significatifs récents, notamment : l'assemblage des amenées de courant HTS, la réalisation des chambres LSS, des tubes HET, d'enveloppes céramiques pour détecteurs PET-HPD, le brasage de RFQ, la soudure du Barrel d'ATLAS ou encore le soudage des lignes de thermalisation du toroïde d'AT...

  5. Comparison between immunomagnetic separation, coupled with immunofluorescence, and the techniques of Faust et al. and of Lutz for the diagnosis of Giardia lamblia cysts in human feces

    Directory of Open Access Journals (Sweden)

    Souza Doris Sobral Marques

    2003-01-01

    Full Text Available In the present study, the performance of Immunomagnetic Separation technique, coupled with Immunofluorescence (IMS-IFA, was compared with the FAUST et al. and Lutz parasitological techniques for the detection of Giardia lamblia cysts in human feces. One hundred and twenty-seven samples were evaluated by the three techniques at the same time showing a rate of cyst detection of 27.5% by IMS-IFA and 15.7% by both Faust et al. and Lutz techniques. Data analysis showed a higher sensitivity of IMS-IFA for the detection of G. lamblia cysts in comparison with the techniques of FAUST et al. and Lutz. The use of this methodology as a routine procedure enables the processing of many samples simultaneously, in order to increase recovery rate of G. lamblia cysts and reduce the time of sample storage.

  6. Techniques conventionelles et innovantes, et solvants alternatifs pour l’extraction des lipides de micro-organismes

    Directory of Open Access Journals (Sweden)

    Abert Vian Maryline

    2013-11-01

    Full Text Available Cette revue propose un panorama complet des connaissances actuelles sur les microorganismes sources de lipides utilisés comme biocarburant. Elle fournit les éléments nécessaires à la compréhension de la culture des microorganismes (micro-algues, levures, bactéries et champignons et de leur capacité à accumuler les lipides. Des techniques conventionnelles et innovantes ainsi que des solvants alternatifs pour extraire les lipides ont été détaillés.

  7. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  8. Science et Technique, Sciences de la Santé

    African Journals Online (AJOL)

    AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search · USING AJOL · RESOURCES. Science et Technique, Sciences de la Santé. Journal Home > Vol ... The journal is focused on health sciences in general. It publishes articles ...

  9. Technique, travail et industrialisation de la noix de cajou au ...

    African Journals Online (AJOL)

    gestion du temps, le contrôle et la vigilance. .... Le système technique leur impose une augmentation très nette de la durée du travail, marquée par la violence des rythmes de production et la fatigue physique sévère, accompagnée de lésions.

  10. Two sampling techniques for game meat

    OpenAIRE

    van der Merwe, Maretha; Jooste, Piet J.; Hoffman, Louw C.; Calitz, Frikkie J.

    2013-01-01

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling...

  11. Mechanics and electronics as auxiliary techniques in nuclear research and exploitation; Mecanique et electronique auxiliaires de la recherche et de l'exploitation nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J. [Commissariat a l' energie atomique et aux energies alternatives - CEA, Centre d' Etudes nucleaires de Saclay, Departement Electronique, Groupe Controle des Reacteurs (France)

    1959-07-01

    Electronics and mechanics form the basic techniques used in the field of measurement and control in nuclear physics experiments, and in nuclear machine installations. The delegate describes some instruments typical of the use of these techniques in the fields of calculation, detection, amplification and nuclear Installations. Reprint of a paper published in 'Bulletin S.F.M.' n. 25 (3. quarter 1957) [French] L'electronique et la mecanique constituent les techniques de base utilisees clans le domaine des mesures et du controle effectues dans les experiences de physique nucleaire et dans les installations des engins nucleaires. Le Conferencier decrit plusieurs appareils caracteristiques de l'emploi de ces techniques dans les domaines du calcul, des detecteurs, de l'amplification et des lnstallations nucleaires. Reproduction d'un article publie dans le 'Bulletin S.F.M.' n. 25 (3e trimestre 1957)

  12. Amorphous and liquid samples structure and density measurements at high pressure - high temperature using diffraction and imaging techniques

    Science.gov (United States)

    Guignot, N.; King, A.; Clark, A. N.; Perrillat, J. P.; Boulard, E.; Morard, G.; Deslandes, J. P.; Itié, J. P.; Ritter, X.; Sanchez-Valle, C.

    2016-12-01

    Determination of the density and structure of liquids such as iron alloys, silicates and carbonates is a key to understand deep Earth structure and dynamics. X-ray diffraction provided by large synchrotron facilities gives excellent results as long as the signal scattered from the sample can be isolated from its environment. Different techniques already exist; we present here the implementation and the first results given by the combined angle- and energy-dispersive structural analysis and refinement (CAESAR) technique introduced by Wang et al. in 2004, that has never been used in this context. It has several advantages in the study of liquids: 1/ the standard energy-dispersive technique (EDX), fast and compatible with large multi-anvil presses frames, is used for fast analysis free of signal pollution from the sample environment 2/ some limitations of the EDX technique (homogeneity of the sample, low resolution) are irrelevant in the case of liquid signals, others (wrong intensities, escape peaks artifacts, background subtraction) are solved by the CAESAR technique 3/ high Q data (up to 15 A-1 and more) can be obtained in a few hours (usually less than 2). We present here the facilities available on the PSICHE beamline (SOLEIL synchrotron, France) and a few results obtained using a Paris-Edinburgh (PE) press and a 1200 tons load capacity multi-anvil press with a (100) DIA compression module. X-ray microtomography, used in conjunction with a PE press featuring rotating anvils (RotoPEc, Philippe et al., 2013) is also very effective, by simply measuring the 3D volume of glass or liquid spheres at HPHT, thus providing density. This can be done in conjunction with the CAESAR technique and we illustrate this point. Finally, absorption profiles can be obtained via imaging techniques, providing another independent way to measure the density of these materials. References Y. Wang et al., A new technique for angle-dispersive powder diffraction using an energy

  13. Two sampling techniques for game meat

    Directory of Open Access Journals (Sweden)

    Maretha van der Merwe

    2013-03-01

    Full Text Available A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g and square centimetres (cm2 for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12 that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13 and analyses performed for aerobic plate count (APC, Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  14. Two sampling techniques for game meat.

    Science.gov (United States)

    van der Merwe, Maretha; Jooste, Piet J; Hoffman, Louw C; Calitz, Frikkie J

    2013-03-20

    A study was conducted to compare the excision sampling technique used by the export market and the sampling technique preferred by European countries, namely the biotrace cattle and swine test. The measuring unit for the excision sampling was grams (g) and square centimetres (cm2) for the swabbing technique. The two techniques were compared after a pilot test was conducted on spiked approved beef carcasses (n = 12) that statistically proved the two measuring units correlated. The two sampling techniques were conducted on the same game carcasses (n = 13) and analyses performed for aerobic plate count (APC), Escherichia coli and Staphylococcus aureus, for both techniques. A more representative result was obtained by swabbing and no damage was caused to the carcass. Conversely, the excision technique yielded fewer organisms and caused minor damage to the carcass. The recovery ratio from the sampling technique improved 5.4 times for APC, 108.0 times for E. coli and 3.4 times for S. aureus over the results obtained from the excision technique. It was concluded that the sampling methods of excision and swabbing can be used to obtain bacterial profiles from both export and local carcasses and could be used to indicate whether game carcasses intended for the local market are possibly on par with game carcasses intended for the export market and therefore safe for human consumption.

  15. The multi-sphere technique. 1 - general characteristics and applications; La technique multisphere. 1 - caracteristiques generales et applications

    Energy Technology Data Exchange (ETDEWEB)

    Zaborcwski, H [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1965-07-01

    A study is made of the general characteristics and the applications of the multisphere technique for flux measurements, dosimetry and the spectrometry of neutron sources ranging from thermal, up to 7 MeV neutrons. We give the equations relating to three fluxmeters (proportional long counters) for the measurements of the flux. Other equations have been derived : 1 - for multi-collision rad and rem dosimetry and first collision rad dosimetry; 2 - for the spectrometry and dosimetry of neutrons in five energy bands using a method similar to that used by threshold detectors. (author) [French] Nous etudions les caracteristiques generales et les applications de la technique multisphere pour les mesures de flux, la dosimetrie et la spectrometrie des sources de neutrons depuis les thermiques jusqu'a 7 MeV. Nous donnons les equations relatives a trois fluxmetres (longs compteurs equivalents) pour les mesures en flux. D'autres equations ont ete derivees: 1 - pour la dosimetrie en rad et en rem de multicollision et en rad de premiere collision; 2 - pour la spectrometrie et la dosimetrie des neutrons en cinq bandes energetiques suivant une methode voisine de celle utilisee par detecteurs a seuil. (auteur)

  16. Science et Technique, Sciences de la Santé: Submissions

    African Journals Online (AJOL)

    Science et technique, revue scientifique du Centre national de la recherche ... VI. Page de titre. Elle doit comprendre : Titre : le titre qui doit être court, précis, ... éléments originaux qui concernent notamment la démarche diagnostique ou le ...

  17. Radioisotope Sample Measurement Techniques in Medicine and Biology. Proceedings of the Symposium on Radioisotope Sample Measurement Techniques

    International Nuclear Information System (INIS)

    1965-01-01

    The medical and biological applications of radioisotopes depend on two basically different types of measurements, those on living subjects in vivo and those on samples in vitro. The International Atomic Energy Agency has in the past held several meetings on in vivo measurement techniques, notably whole-body counting and radioisotope scanning. The present volume contains the Proceedings of the first Symposium the Agency has organized to discuss the various aspects of techniques for sample measurement in vitro. The range of these sample measurement techniques is very wide. The sample may weigh a few milligrams or several hundred grams, and may be in the gaseous, liquid or solid state. Its radioactive content may consist of a single, known radioisotope or several unknown ones. The concentration of radioactivity may be low, medium or high. The measurements may be made manually or automatically and any one of the many radiation detectors now available may be used. The 53 papers presented at the Symposium illustrate the great variety of methods now in use for radioactive- sample measurements. The first topic discussed is gamma-ray spectrometry, which finds an increasing number of applications in sample measurements. Other sections of the Proceedings deal with: the use of computers in gamma-ray spectrometry and multiple tracer techniques; recent developments in activation analysis where both gamma-ray spectrometry and computing techniques are applied; thin-layer and paper radio chromatographic techniques for use with low energy beta-ray emitters; various aspects of liquid scintillation counting techniques in the measurement of alpha- and beta-ray emitters, including chemical and colour quenching; autoradiographic techniques; calibration of equipment; and standardization of radioisotopes. Finally, some applications of solid-state detectors are presented; this section may be regarded as a preview of important future developments. The meeting was attended by 203 participants

  18. Critical evaluation of sample pretreatment techniques.

    Science.gov (United States)

    Hyötyläinen, Tuulia

    2009-06-01

    Sample preparation before chromatographic separation is the most time-consuming and error-prone part of the analytical procedure. Therefore, selecting and optimizing an appropriate sample preparation scheme is a key factor in the final success of the analysis, and the judicious choice of an appropriate procedure greatly influences the reliability and accuracy of a given analysis. The main objective of this review is to critically evaluate the applicability, disadvantages, and advantages of various sample preparation techniques. Particular emphasis is placed on extraction techniques suitable for both liquid and solid samples.

  19. Les techniques de coloration et de screening des frottis cervicaux ...

    African Journals Online (AJOL)

    Les techniques de coloration et de screening des frottis cervicaux. ... précocement tout cancer du col de l'utérus par la mise en évidence des lésions ... in terms of frequency, the second cancer concerning the women after the breast cancer.

  20. Concepteur de matériel pédagogique et rédacteur technique (h/f ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Le titulaire veille à ce que ce contenu fasse mieux connaître les services et les outils de GI-TI, y compris les changements récents. Il se tient au courant des changements survenus dans le domaine et entretient des relations avec la communauté locale et virtuelle de l'apprentissage et de la rédaction technique afin de ...

  1. Newly introduced sample preparation techniques: towards miniaturization.

    Science.gov (United States)

    Costa, Rosaria

    2014-01-01

    Sampling and sample preparation are of crucial importance in an analytical procedure, representing quite often a source of errors. The technique chosen for the isolation of analytes greatly affects the success of a chemical determination. On the other hand, growing concerns about environmental and human safety, along with the introduction of international regulations for quality control, have moved the interest of scientists towards specific needs. Newly introduced sample preparation techniques are challenged to meet new criteria: (i) miniaturization, (ii) higher sensitivity and selectivity, and (iii) automation. In this survey, the most recent techniques introduced in the field of sample preparation will be described and discussed, along with many examples of applications.

  2. Applications of prospecting geochemical techniques to the search for and to the study of uranium deposits in metropolitan France; Applications des techniques geochimiques de prospection a la recherche et a l'etude des gites uraniferes en France metropolitaine

    Energy Technology Data Exchange (ETDEWEB)

    Grimbert, Arnold

    1957-07-01

    After having recalled facts which leaded the CEA to use new geochemical techniques for the prospecting of uranium deposits through sampling and analysis of soils and waters, the author describes the organisation and methods implemented for this prospecting activity: team composition for sampling and analysis, role of each engineer and technician in the prospecting stages (preliminary study, routine prospecting, result interpretation), sampling and analysis processes. He also reports campaigns of geochemical prospecting: study of the La Chapelle Largeau deposit (objectives, geological context, preliminary study, routine prospecting, study of geochemical anomalies), tactical research on Verneix indices (study of radioactivity anomaly discovered by radio-prospecting), strategical searches in a non prospected area in the South of Avallon. The author discusses the issues of efficiency and cost price of this geochemical prospecting technique in soils and in waters. Appendices present the equipment and operation modality for soil sampling, and for soil sample preparation, and principles, equipment and products for soil analysis and for water analysis [French] A la suite des resultats satisfaisants obtenus dans la recherche de methodes de dosage adaptees au cas de l'uranium, la Direction des Recherches Minieres du Commissariat a l'Energie atomique a decide, en decembre 1954, d'utiliser, conjointement avec les methodes classiques de prospection, les techniques geochimiques pour la recherche et l'etude des gites uraniferes. Ces applications pratiques ont ete confiees a une Section de Geochimie dont l'organisation, les moyens en personnel et en materiel, ainsi que les methodes de travail, font l'objet d'un expose detaille. Quelques exemples de prospection, en France metropolitaine, montrent la nature des problemes poses (etude d'un gisement connu, recherche tactique sur des indices, recherche strategique dans une region non prospectee), les methodes utilisees pour les

  3. Sampling Polya-Gamma random variates: alternate and approximate techniques

    OpenAIRE

    Windle, Jesse; Polson, Nicholas G.; Scott, James G.

    2014-01-01

    Efficiently sampling from the P\\'olya-Gamma distribution, ${PG}(b,z)$, is an essential element of P\\'olya-Gamma data augmentation. Polson et. al (2013) show how to efficiently sample from the ${PG}(1,z)$ distribution. We build two new samplers that offer improved performance when sampling from the ${PG}(b,z)$ distribution and $b$ is not unity.

  4. Comparison of sampling techniques for use in SYVAC

    International Nuclear Information System (INIS)

    Dalrymple, G.J.

    1984-01-01

    The Stephen Howe review (reference TR-STH-1) recommended the use of a deterministic generator (DG) sampling technique for sampling the input values to the SYVAC (SYstems Variability Analysis Code) program. This technique was compared with Monte Carlo simple random sampling (MC) by taking a 1000 run case of SYVAC using MC as the reference case. The results show that DG appears relatively inaccurate for most values of consequence when used with 11 sample intervals. If 22 sample intervals are used then DG generates cumulative distribution functions that are statistically similar to the reference distribution. 400 runs of DG or MC are adequate to generate a representative cumulative distribution function. The MC technique appears to perform better than DG for the same number of runs. However, the DG predicts higher doses and in view of the importance of generating data in the high dose region this sampling technique with 22 sample intervals is recommended for use in SYVAC. (author)

  5. Essences végétales et techniques de restauration des zones d'érosion

    African Journals Online (AJOL)

    SARAH

    30 sept. 2013 ... Objectif : Cette étude examine les meilleures espèces végétales et les techniques d'aménagement ... l'élaboration de stratégies durables de restauration des zones soudano-sahéliennes dégradées. ..... naturelle globale de 4,4% soit 12 plants et une mortalité .... des espèces et aux conditions climatiques.

  6. Proteomic Challenges: Sample Preparation Techniques for Microgram-Quantity Protein Analysis from Biological Samples

    Directory of Open Access Journals (Sweden)

    Peter Feist

    2015-02-01

    Full Text Available Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed.

  7. Proteomic Challenges: Sample Preparation Techniques for Microgram-Quantity Protein Analysis from Biological Samples

    Science.gov (United States)

    Feist, Peter; Hummon, Amanda B.

    2015-01-01

    Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower) and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed. PMID:25664860

  8. Proteomic challenges: sample preparation techniques for microgram-quantity protein analysis from biological samples.

    Science.gov (United States)

    Feist, Peter; Hummon, Amanda B

    2015-02-05

    Proteins regulate many cellular functions and analyzing the presence and abundance of proteins in biological samples are central focuses in proteomics. The discovery and validation of biomarkers, pathways, and drug targets for various diseases can be accomplished using mass spectrometry-based proteomics. However, with mass-limited samples like tumor biopsies, it can be challenging to obtain sufficient amounts of proteins to generate high-quality mass spectrometric data. Techniques developed for macroscale quantities recover sufficient amounts of protein from milligram quantities of starting material, but sample losses become crippling with these techniques when only microgram amounts of material are available. To combat this challenge, proteomicists have developed micro-scale techniques that are compatible with decreased sample size (100 μg or lower) and still enable excellent proteome coverage. Extraction, contaminant removal, protein quantitation, and sample handling techniques for the microgram protein range are reviewed here, with an emphasis on liquid chromatography and bottom-up mass spectrometry-compatible techniques. Also, a range of biological specimens, including mammalian tissues and model cell culture systems, are discussed.

  9. APPROCHE MORPHOLOGIQUE DE L’ÉCREVISSE ASTACUS ASTACUS L. 1758 ASSOCIÉE À L’IMAGERIE (TOMOSCANNER ET ÉCHO-DOPPLER ET AUX TECHNIQUES IMMUNOHISTOCHIMIQUES

    Directory of Open Access Journals (Sweden)

    BENYAHIA T. M.

    2002-07-01

    Full Text Available Après avoir souligné, d’une manière concrète, les difficultés de la dissection et le repérage par les méthodes classiques, nous avons essayé dans ce travail d’aborder l’apport de la macroscopie indirecte de l’animal grâce à la radiologie (échographie, tomoscanner, lavement baryté afin de vérifier les donnés anatomiques sur l’écrevisse à pattes rouges, complété par des techniques microscopiques. Dans notre travail, l’adaptation pour l’écrevisse de techniques nouvelles de radiologie (tomoscanner et échographie complétées par les études d’histologie (colorations et immunohistochimie ont permis de se rendre compte des possibilités qu’elles offrent pour l’exploration dynamique et le repérage précis des organes et pour le diagnostic de maladies histopathologiques et ceci sans porter atteinte à l’animal. Le but de cette approche est de mettre au point des moyens d’investigation sur l’animal vivant pour mieux cerner les éventuels états pathologiques touchant surtout ses organes profonds et contribuer ainsi à préserver cette espèce menacée par la pollution des milieux astacicoles et par la sécheresse persistante que connaît le Maroc ces dernières années.

  10. NAIL SAMPLING TECHNIQUE AND ITS INTERPRETATION

    Directory of Open Access Journals (Sweden)

    TZAR MN

    2011-01-01

    Full Text Available The clinical suspicion of onychomyosis based on appearance of the nails, requires culture for confirmation. This is because treatment requires prolonged use of systemic agents which may cause side effects. One of the common problems encountered is improper nail sampling technique which results in loss of essential information. The unfamiliar terminologies used in reporting culture results may intimidate physicians resulting in misinterpretation and hamper treatment decision. This article provides a simple guide on nail sampling technique and the interpretation of culture results.

  11. Development of sampling techniques for ITER Type B radwaste

    International Nuclear Information System (INIS)

    Hong, Kwon Pyo; Kim, Sung Geun; Jung, Sang Hee; Oh, Wan Ho; Park, Myung Chul; Kim, Hee Moon; Ahn, Sang Bok

    2016-01-01

    There are several difficulties and limitation in sampling activities. As the Type B radwaste components are mostly metallic(mostly stainless steel) and bulk(∼ 1 m in size and ∼ 100 mm in thickness), it is difficult in taking samples from the surface of Type B radwaste by remote operation. But also, sampling should be performed without use of any liquid coolant to avoid the spread of contamination. And all sampling procedures are carried in the hot cell red zone with remote operation. Three kinds of sampling techniques are being developed. They are core sampling, chip sampling, and wedge sampling, which are the candidates of sampling techniques to be applied to ITER hot cell. Object materials for sampling are stainless steel or Cu alloy block in order to simulate ITER Type B radwaste. The best sampling technique for ITER Type B radwaste among the three sampling techniques will be suggested in several months after finishing the related experiment

  12. Development of sampling techniques for ITER Type B radwaste

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Kwon Pyo; Kim, Sung Geun; Jung, Sang Hee; Oh, Wan Ho; Park, Myung Chul; Kim, Hee Moon; Ahn, Sang Bok [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    There are several difficulties and limitation in sampling activities. As the Type B radwaste components are mostly metallic(mostly stainless steel) and bulk(∼ 1 m in size and ∼ 100 mm in thickness), it is difficult in taking samples from the surface of Type B radwaste by remote operation. But also, sampling should be performed without use of any liquid coolant to avoid the spread of contamination. And all sampling procedures are carried in the hot cell red zone with remote operation. Three kinds of sampling techniques are being developed. They are core sampling, chip sampling, and wedge sampling, which are the candidates of sampling techniques to be applied to ITER hot cell. Object materials for sampling are stainless steel or Cu alloy block in order to simulate ITER Type B radwaste. The best sampling technique for ITER Type B radwaste among the three sampling techniques will be suggested in several months after finishing the related experiment.

  13. Boat sampling technique for assessment of ageing of components

    International Nuclear Information System (INIS)

    Kumar, Kundan; Shyam, T.V.; Kayal, J.N.; Rupani, B.B.

    2006-01-01

    Boat sampling technique (BST) is a surface sampling technique, which has been developed for obtaining, in-situ, metal samples from the surface of an operating component without affecting its operating service life. The BST is non-destructive in nature and the sample is obtained without plastic deformation or without thermal degradation of the parent material. The shape and size of the sample depends upon the shape of the cutter and the surface geometry of the parent material. Miniature test specimens are generated from the sample and the specimens are subjected to various tests, viz. Metallurgical Evaluation, Metallographic Evaluation, Micro-hardness Evaluation, sensitisation test, small punch test etc. to confirm the integrity and assessment of safe operating life of the component. This paper highlights design objective of boat sampling technique, description of sampling module, sampling cutter and its performance evaluation, cutting process, boat samples, operational sequence of sampling module, qualification of sampling module, qualification of sampling technique, qualification of scooped region of the parent material, sample retrieval system, inspection, testing and examination to be carried out on the boat samples and scooped region. (author)

  14. The importance of sound methodology in environmental DNA sampling

    Science.gov (United States)

    T. M. Wilcox; K. J. Carim; M. K. Young; K. S. McKelvey; T. W. Franklin; M. K. Schwartz

    2018-01-01

    Environmental DNA (eDNA) sampling - which enables inferences of species’ presence from genetic material in the environment - is a powerful tool for sampling rare fishes. Numerous studies have demonstrated that eDNA sampling generally provides greater probabilities of detection than traditional techniques (e.g., Thomsen et al. 2012; McKelvey et al. 2016; Valentini et al...

  15. Urine sampling techniques in symptomatic primary-care patients

    DEFF Research Database (Denmark)

    Holm, Anne; Aabenhus, Rune

    2016-01-01

    in infection rate between mid-stream-clean-catch, mid-stream-urine and random samples. Conclusions: At present, no evidence suggests that sampling technique affects the accuracy of the microbiological diagnosis in non-pregnant women with symptoms of urinary tract infection in primary care. However......Background: Choice of urine sampling technique in urinary tract infection may impact diagnostic accuracy and thus lead to possible over- or undertreatment. Currently no evidencebased consensus exists regarding correct sampling technique of urine from women with symptoms of urinary tract infection...... a randomized or paired design to compare the result of urine culture obtained with two or more collection techniques in adult, female, non-pregnant patients with symptoms of urinary tract infection. We evaluated quality of the studies and compared accuracy based on dichotomized outcomes. Results: We included...

  16. Non-terminal blood sampling techniques in guinea pigs.

    Science.gov (United States)

    Birck, Malene M; Tveden-Nyborg, Pernille; Lindblad, Maiken M; Lykkesfeldt, Jens

    2014-10-11

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e.g., the saphenous and jugular veins, each technique containing both advantages and disadvantages(4,5). Here, we present four different blood sampling techniques for either conscious or anaesthetized guinea pigs. The procedures are all non-terminal procedures provided that sample volumes and number of samples do not exceed guidelines for blood collection in laboratory animals(6). All the described methods have been thoroughly tested and applied for repeated in vivo blood sampling in studies within our research facility.

  17. Les patrimoines mobiliers scientifique et technique : spécificités de leur restauration, de leur conservation et de leur valorisation

    Directory of Open Access Journals (Sweden)

    Philippe Tomsin

    2007-10-01

    Full Text Available Le patrimoine mobilier scientifique et technique, de par ses matériaux et les pathologies particulières qu'il connaît, pose des problèmes spécifiques en matière de conservation et de restauration. L'auteur inventorie les aspects de cette problématique, y compris la question cruciale des lieux de conservation et de valorisation de ce patrimoine particulier. Il propose à la réflexion quelques règles déontologiques.The scientific and technical movable heritage, because of its materials and special pathologies, gives some specific problems of conservation and restoration. The author inventories the aspects of these problems, including the crucial question of the places of conservation and valorisation of this particular heritage. He proposes a thought about some deontological rules.

  18. Differences in sampling techniques on total post-mortem tryptase.

    Science.gov (United States)

    Tse, R; Garland, J; Kesha, K; Elstub, H; Cala, A D; Ahn, Y; Stables, S; Palmiere, C

    2017-11-20

    The measurement of mast cell tryptase is commonly used to support the diagnosis of anaphylaxis. In the post-mortem setting, the literature recommends sampling from peripheral blood sources (femoral blood) but does not specify the exact sampling technique. Sampling techniques vary between pathologists, and it is unclear whether different sampling techniques have any impact on post-mortem tryptase levels. The aim of this study is to compare the difference in femoral total post-mortem tryptase levels between two sampling techniques. A 6-month retrospective study comparing femoral total post-mortem tryptase levels between (1) aspirating femoral vessels with a needle and syringe prior to evisceration and (2) femoral vein cut down during evisceration. Twenty cases were identified, with three cases excluded from analysis. There was a statistically significant difference (paired t test, p sampling methods. The clinical significance of this finding and what factors may contribute to it are unclear. When requesting post-mortem tryptase, the pathologist should consider documenting the exact blood collection site and method used for collection. In addition, blood samples acquired by different techniques should not be mixed together and should be analyzed separately if possible.

  19. Microextraction sample preparation techniques in biomedical analysis.

    Science.gov (United States)

    Szultka, Malgorzata; Pomastowski, Pawel; Railean-Plugaru, Viorica; Buszewski, Boguslaw

    2014-11-01

    Biologically active compounds are found in biological samples at relatively low concentration levels. The sample preparation of target compounds from biological, pharmaceutical, environmental, and food matrices is one of the most time-consuming steps in the analytical procedure. The microextraction techniques are dominant. Metabolomic studies also require application of proper analytical technique for the determination of endogenic metabolites present in biological matrix on trace concentration levels. Due to the reproducibility of data, precision, relatively low cost of the appropriate analysis, simplicity of the determination, and the possibility of direct combination of those techniques with other methods (combination types on-line and off-line), they have become the most widespread in routine determinations. Additionally, sample pretreatment procedures have to be more selective, cheap, quick, and environmentally friendly. This review summarizes the current achievements and applications of microextraction techniques. The main aim is to deal with the utilization of different types of sorbents for microextraction and emphasize the use of new synthesized sorbents as well as to bring together studies concerning the systematic approach to method development. This review is dedicated to the description of microextraction techniques and their application in biomedical analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006 - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collabora- tion avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  1. EXIGENCES TECHNIQUES DANS LA CONSTRUCTION ET REGLEMENTATION : ETUDE D’UN EXEMPLE DE LOGEMENT COLLECTIF A AIN-SMARA (ALGERIE

    Directory of Open Access Journals (Sweden)

    B BENRACHI

    2002-12-01

    Full Text Available La construction d’un édifice de qualité standard et répondant aux exigences techniques est   obtenue grâce au développement du savoir-faire et au respect des règles de l’art et de la réglementation en vigueur.  Une étude détaillée sur les  exigences techniques et le respect de la réglementation  d’un logement en collectif  nouvellement construit et inhabité à Ain-Smara, nous a montré  qu’il y a une satisfaction pour certaines d'entre-elles et une non-conformité pour d’autres. Il en résulte que le degré de satisfaction de ce logement est inférieur à celui recommandé dans le cadre de la réglementation, ce qui diminue sa qualité par rapport au standard exigé.

  2. New materials for sample preparation techniques in bioanalysis.

    Science.gov (United States)

    Nazario, Carlos Eduardo Domingues; Fumes, Bruno Henrique; da Silva, Meire Ribeiro; Lanças, Fernando Mauro

    2017-02-01

    The analysis of biological samples is a complex and difficult task owing to two basic and complementary issues: the high complexity of most biological matrices and the need to determine minute quantities of active substances and contaminants in such complex sample. To succeed in this endeavor samples are usually subject to three steps of a comprehensive analytical methodological approach: sample preparation, analytes isolation (usually utilizing a chromatographic technique) and qualitative/quantitative analysis (usually with the aid of mass spectrometric tools). Owing to the complex nature of bio-samples, and the very low concentration of the target analytes to be determined, selective sample preparation techniques is mandatory in order to overcome the difficulties imposed by these two constraints. During the last decade new chemical synthesis approaches has been developed and optimized, such as sol-gel and molecularly imprinting technologies, allowing the preparation of novel materials for sample preparation including graphene and derivatives, magnetic materials, ionic liquids, molecularly imprinted polymers, and much more. In this contribution we will review these novel techniques and materials, as well as their application to the bioanalysis niche. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Improved technique for measuring the size distribution of black carbon particles in rainwater and snow samples

    Science.gov (United States)

    Mori, T.; Moteki, N.; Ohata, S.; Koike, M.; Azuma, K. G.; Miyazaki, Y.; Kondo, Y.

    2015-12-01

    Black carbon (BC) is the strongest contributor to sunlight absorption among atmospheric aerosols. Quantitative understanding of wet deposition of BC, which strongly affects the spatial distribution of BC, is important to improve our understandings on climate change. We have devised a technique for measuring the masses of individual BC particles in rainwater and snow samples, as a combination of a nebulizer and a single-particle soot photometer (SP2) (Ohata et al. 2011, 2013; Schwarz et al. 2012; Mori et al. 2014). We show two important improvements in this technique: 1)We have extended the upper limit of detectable BC particle diameter from 0.9 μm to about 4.0 μm by modifying the photodetector for measuring the laser-induced incandescence signal. 2)We introduced a pneumatic nebulizer Marin-5 (Cetac Technologies Inc., Omaha, NE, USA) and experimentally confirmed its high extraction efficiency (~50%) independent of particle diameter up to 2.0 μm. Using our improved system, we simultaneously measured the size distribution of BC particles in air and rainwater in Tokyo. We observed that the size distribution of BC in rainwater was larger than that in air, indicating that large BC particles were effectively removed by precipitation. We also observed BC particles with diameters larger than 1.0 μm, indicating that further studies of wet deposition of BC will require the use of the modified SP2.

  4. Séminaire de l'enseignement technique : Forum AutoCAD 2006 et AutoCAD Mechanical 2006

    - French version only

    CERN Multimedia

    Davide Vitè

    2005-01-01

    Jeudi 17 novembre 2005 de 14:30 à 16:30 - Training Centre Auditorium, Bât 593 Forum AutoCAD 2006 et AutoCAD Mechanical 2006 CADSCHOOL, CH-1207 GENEVE, Suisse Ce nouveau séminaire de l'Enseignement technique, organisé en forme de forum et en collaboration avec TS-MME et notre entreprise partenaire en formation, sera consacré à la présentation de la nouvelle version d'AutoCAD, AutoCAD 2006 et AutoCAD Mechanical 2006, disponible au CERN. Au programme : Présentation d'AutoCAD Mechanical 2006 Améliorations par rapport à AutoCAD Mechanical 6 Power Pack Questions - Réponses Langue: Français. Séminaire libre, sans inscription. Organisateurs: Manfred Mayer / TS-MME / 74499 ; Davide Vitè / HR-PMD / 75141 Pour plus d'information, veuillez SVP visiter les pages des Séminaires de l'Enseignement Technique à l'adresse http://www.cern.ch/TechnicalTraining/special/TTseminars.asp . ENSEIGNEMENT TECHNIQUE TECHNICAL TRAINING technical.training@cern.ch

  5. Yield strength, shear stress and toughness of YBCO samples textured by Bridgman technique

    International Nuclear Information System (INIS)

    Roa, J J; Capdevila, X G; Martinez, M; Segarra, M; Jimenez-Pique, E

    2008-01-01

    Mechanical properties of the orthorhombic phase of YBa 2 Cu 3 O 7-δ (Y-123) at room temperature have been investigated at different applied loads using nanoindentation technique. The study was carried out for several monodomains on the (001) planes for textured Bridgman samples with dispersed Y 2 BaCuO 5 (Y-211) particles as pinning centers. The yield strength (σ ys ), shear stress (τ m ) and toughness (K IC ) of Y123/Y211composite was determined at different applied loads. First and second mechanical properties have been calculated though the Hertz equations and the last one with Lawn et al. equations. Finally, the ultra-low imprints obtained by nanoindentation have been correlated with parameters obtained by Field Emission Scanning Electron Microscope (FE-SEM)

  6. A comparative study of sampling techniques for monitoring carcass contamination

    NARCIS (Netherlands)

    Snijders, J.M.A.; Janssen, M.H.W.; Gerats, G.E.; Corstiaensen, G.P.

    1984-01-01

    Four bacteriological sampling techniques i.e. the excision, double swab, agar contract and modified agar contact techniques were compared by sampling pig carcasses before and after chilling. As well as assessing the advantages and disadvantages of the techniques particular attention was paid to

  7. Sample preparation for special PIE-techniques at ITU

    International Nuclear Information System (INIS)

    Toscano, E.H.; Manzel, R.

    2002-01-01

    Several sample preparation techniques were developed and installed in hot cells. The techniques were conceived to evaluate the performance of highly burnt fuel rods and include: (a) a device for the removal of the fuel, (b) a method for the preparation of the specimen ends for the welding of new end caps and for the careful cleaning of samples for Transmission Electron Microscopy and Glow Discharge Mass Spectroscopy, (c) a sample pressurisation device for long term creep tests, and (d) a diameter measuring device for creep or burst samples. Examples of the determination of the mechanical properties, the behaviour under transient conditions and for the assessment of the corrosion behaviour of high burnup cladding materials are presented. (author)

  8. New trends in sample preparation techniques for environmental analysis.

    Science.gov (United States)

    Ribeiro, Cláudia; Ribeiro, Ana Rita; Maia, Alexandra S; Gonçalves, Virgínia M F; Tiritan, Maria Elizabeth

    2014-01-01

    Environmental samples include a wide variety of complex matrices, with low concentrations of analytes and presence of several interferences. Sample preparation is a critical step and the main source of uncertainties in the analysis of environmental samples, and it is usually laborious, high cost, time consuming, and polluting. In this context, there is increasing interest in developing faster, cost-effective, and environmentally friendly sample preparation techniques. Recently, new methods have been developed and optimized in order to miniaturize extraction steps, to reduce solvent consumption or become solventless, and to automate systems. This review attempts to present an overview of the fundamentals, procedure, and application of the most recently developed sample preparation techniques for the extraction, cleanup, and concentration of organic pollutants from environmental samples. These techniques include: solid phase microextraction, on-line solid phase extraction, microextraction by packed sorbent, dispersive liquid-liquid microextraction, and QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe).

  9. Sample Preparation Report of the Fourth OPCW Confidence Building Exercise on Biomedical Sample Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Udey, R. N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Corzett, T. H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Alcaraz, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-07-03

    Following the successful completion of the 3rd biomedical confidence building exercise (February 2013 – March 2013), which included the analysis of plasma and urine samples spiked at low ppb levels as part of the exercise scenario, another confidence building exercise was targeted to be conducted in 2014. In this 4th exercise, it was desired to focus specifically on the analysis of plasma samples. The scenario was designed as an investigation of an alleged use of chemical weapons where plasma samples were collected, as plasma has been reported to contain CWA adducts which remain present in the human body for several weeks (Solano et al. 2008). In the 3rd exercise most participants used the fluoride regeneration method to analyze for the presence of nerve agents in plasma samples. For the 4th biomedical exercise it was decided to evaluate the analysis of human plasma samples for the presence/absence of the VX adducts and aged adducts to blood proteins (e.g., VX-butyrylcholinesterase (BuChE) and aged BuChE adducts using a pepsin digest technique to yield nonapeptides; or equivalent). As the aging of VX-BuChE adducts is relatively slow (t1/2 = 77 hr at 37 °C [Aurbek et al. 2009]), soman (GD), which ages much more quickly (t1/2 = 9 min at 37 °C [Masson et al. 2010]), was used to simulate an aged VX sample. Additional objectives of this exercise included having laboratories assess novel OP-adducted plasma sample preparation techniques and analytical instrumentation methodologies, as well as refining/designating the reporting formats for these new techniques.

  10. Non-terminal blood sampling techniques in Guinea pigs

    DEFF Research Database (Denmark)

    Birck, Malene Muusfeldt; Tveden-Nyborg, Pernille; Lindblad, Maiken Marie

    2014-01-01

    Guinea pigs possess several biological similarities to humans and are validated experimental animal models(1-3). However, the use of guinea pigs currently represents a relatively narrow area of research and descriptive data on specific methodology is correspondingly scarce. The anatomical features...... of guinea pigs are slightly different from other rodent models, hence modulation of sampling techniques to accommodate for species-specific differences, e.g., compared to mice and rats, are necessary to obtain sufficient and high quality samples. As both long and short term in vivo studies often require...... repeated blood sampling the choice of technique should be well considered in order to reduce stress and discomfort in the animals but also to ensure survival as well as compliance with requirements of sample size and accessibility. Venous blood samples can be obtained at a number of sites in guinea pigs e...

  11. Refinement of NMR structures using implicit solvent and advanced sampling techniques.

    Science.gov (United States)

    Chen, Jianhan; Im, Wonpil; Brooks, Charles L

    2004-12-15

    NMR biomolecular structure calculations exploit simulated annealing methods for conformational sampling and require a relatively high level of redundancy in the experimental restraints to determine quality three-dimensional structures. Recent advances in generalized Born (GB) implicit solvent models should make it possible to combine information from both experimental measurements and accurate empirical force fields to improve the quality of NMR-derived structures. In this paper, we study the influence of implicit solvent on the refinement of protein NMR structures and identify an optimal protocol of utilizing these improved force fields. To do so, we carry out structure refinement experiments for model proteins with published NMR structures using full NMR restraints and subsets of them. We also investigate the application of advanced sampling techniques to NMR structure refinement. Similar to the observations of Xia et al. (J.Biomol. NMR 2002, 22, 317-331), we find that the impact of implicit solvent is rather small when there is a sufficient number of experimental restraints (such as in the final stage of NMR structure determination), whether implicit solvent is used throughout the calculation or only in the final refinement step. The application of advanced sampling techniques also seems to have minimal impact in this case. However, when the experimental data are limited, we demonstrate that refinement with implicit solvent can substantially improve the quality of the structures. In particular, when combined with an advanced sampling technique, the replica exchange (REX) method, near-native structures can be rapidly moved toward the native basin. The REX method provides both enhanced sampling and automatic selection of the most native-like (lowest energy) structures. An optimal protocol based on our studies first generates an ensemble of initial structures that maximally satisfy the available experimental data with conventional NMR software using a simplified

  12. Application of digital sampling techniques to particle identification

    International Nuclear Information System (INIS)

    Bardelli, L.; Poggi, G.; Bini, M.; Carraresi, L.; Pasquali, G.; Taccetti, N.

    2003-01-01

    An application of digital sampling techniques is presented which can greatly simplify experiments involving sub-nanosecond time-mark determinations and energy measurements with nuclear detectors, used for Pulse Shape Analysis and Time of Flight measurements in heavy ion experiments. In this work a 100 M Sample/s, 12 bit analog to digital converter has been used: examples of this technique applied to Silicon and CsI(Tl) detectors in heavy-ions experiments involving particle identification via Pulse Shape analysis and Time of Flight measurements are presented. The system is suited for applications to large detector arrays and to different kinds of detectors. Some preliminary results regarding the simulation of current signals in Silicon detectors are also discussed. (authors)

  13. Sampling techniques for thrips (Thysanoptera: Thripidae) in preflowering tomato.

    Science.gov (United States)

    Joost, P Houston; Riley, David G

    2004-08-01

    Sampling techniques for thrips (Thysanoptera: Thripidae) were compared in preflowering tomato plants at the Coastal Plain Experiment Station in Tifton, GA, in 2000 and 2003, to determine the most effective method of determining abundance of thrips on tomato foliage early in the growing season. Three relative sampling techniques, including a standard insect aspirator, a 946-ml beat cup, and an insect vacuum device, were compared for accuracy to an absolute method and to themselves for precision and efficiency of sampling thrips. Thrips counts of all relative sampling methods were highly correlated (R > 0.92) to the absolute method. The aspirator method was the most accurate compared with the absolute sample according to regression analysis in 2000. In 2003, all sampling methods were considered accurate according to Dunnett's test, but thrips numbers were lower and sample variation was greater than in 2000. In 2000, the beat cup method had the lowest relative variation (RV) or best precision, at 1 and 8 d after transplant (DAT). Only the beat cup method had RV values <25 for all sampling dates. In 2003, the beat cup method had the lowest RV value at 15 and 21 DAT. The beat cup method also was the most efficient method for all sample dates in both years. Frankliniella fusca (Pergande) was the most abundant thrips species on the foliage of preflowering tomato in both years of study at this location. Overall, the best thrips sampling technique tested was the beat cup method in terms of precision and sampling efficiency.

  14. evaluation technique et economique des formules alimentaires de ...

    African Journals Online (AJOL)

    COMPOSITION CHIMIQUE DES INGREDIENTS. ET ALIMENTS COMPOSES UTILISES. Les résultats de l'analyse chimique des différents ingrédients et aliments (tableau 2) ont montré que les tiges de mil et la paille de riz avaient la même teneur en matière azotée totale (5,7 %) qui était environ la moitié de celle de la fane ...

  15. Commercial Ethyl Glucuronide (EtG) and Ethyl Sulfate (EtS) Testing is Not Vulnerable to Incidental Alcohol Exposure in Pregnant Women.

    Science.gov (United States)

    Ondersma, Steven J; Beatty, Jessica R; Rosano, Thomas G; Strickler, Ronald C; Graham, Amy E; Sokol, Robert J

    2016-01-02

    Ethyl Glucoronide (EtG) and Ethyl Sulfate (EtS) have shown promise as biomarkers for alcohol and may be sensitive enough for use with pregnant women in whom even low-level alcohol use is important. However, there have been reports of over-sensitivity of EtG and EtS to incidental exposure to sources such as alcohol-based hand sanitizer. Further, few studies have evaluated these biomarkers among pregnant women, in whom the dynamics of these metabolites may differ. This study evaluated whether commercial EtG-EtS testing was vulnerable to high levels of environmental exposure to alcohol in pregnant women. Two separate samples of five nurses-one pregnant and the other postpartum, all of whom reported high levels of alcohol-based hand sanitizer use-provided urine samples before and 4-8 hours after rinsing with alcohol-based mouthwash and using hand sanitizer. The five pregnant nurses provided urine samples before, during, and after an 8-hour nursing shift, during which they repeatedly cleansed with alcohol-based hand sanitizer (mean 33.8 uses). The five postpartum nurses used hand sanitizer repeatedly between baseline and follow-up urine samples. No urine samples were positive for EtG-EtS at baseline or follow-up, despite use of mouthwash and-in the pregnant sample-heavy use of hand sanitizer (mean of 33.8 uses) throughout the 8-hour shift. Current, commercially available EtG-EtS testing does not appear vulnerable to even heavy exposure to incidental sources of alcohol among pregnant and postpartum women.

  16. Accès à l'eau : des solutions techniques et sociales aident des ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Grâce à la modélisation par ordinateur faisant appel à des techniques de pointe et à la consultation des collectivités, l'organisme bolivien Agua Sustentable a trouvé des solutions politiques à des conflits qui auraient pu s'avérer désastreux au sujet de l'accès à l'eau. Cet organisme de recherche subventionné par le CRDI a ...

  17. Use of nuclear technique in samples for agricultural purposes

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Kerley A. P. de; Sperling, Eduardo Von, E-mail: kerley@ufmg.br, E-mail: kerleyfisica@yahoo.com.br [Department of Sanitary and Environmental Engineering Federal University of Minas Gerais, Belo Horizonte (Brazil); Menezes, Maria Angela B. C.; Jacomino, Vanusa M.F. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-01-15

    The concern related to environment is growing. Due to this, it is needed to determine chemical elements in a large range of concentration. The neutron activation technique (NAA) determines the elemental composition by the measurement of artificial radioactivity in a sample that was submitted to a neutron flux. NAA is a sensitive and accurate technique with low detection limits. An example of application of NAA was the measurement of concentrations of rare earth elements (REE) in waste samples of phosphogypsum (PG) and cerrado soil samples (clayey and sandy soils). Additionally, a soil reference material of the International Atomic Energy Agency (IAEA) was also analyzed. The REE concentration in PG samples was two times higher than those found in national fertilizers, (total of 4,000 mg kg{sup -1}), 154 times greater than the values found in the sandy soil (26 mg kg{sup -1}) and 14 times greater than the in clayey soil (280 mg kg{sup -1}). The experimental results for the reference material were inside the uncertainty of the certified values pointing out the accuracy of the method (95%). The determination of La, Ce, Pr, Nd, Pm, Sm, Eu, Tb, Dy, Ho, Er, Tm, Yb and Lu in the samples and reference material confirmed the versatility of the technique on REE determination in soil and phosphogypsum samples that are matrices for agricultural interest. (author)

  18. Use of nuclear technique in samples for agricultural purposes

    International Nuclear Information System (INIS)

    Oliveira, Kerley A. P. de; Sperling, Eduardo Von; Menezes, Maria Angela B. C.; Jacomino, Vanusa M.F.

    2013-01-01

    The concern related to environment is growing. Due to this, it is needed to determine chemical elements in a large range of concentration. The neutron activation technique (NAA) determines the elemental composition by the measurement of artificial radioactivity in a sample that was submitted to a neutron flux. NAA is a sensitive and accurate technique with low detection limits. An example of application of NAA was the measurement of concentrations of rare earth elements (REE) in waste samples of phosphogypsum (PG) and cerrado soil samples (clayey and sandy soils). Additionally, a soil reference material of the International Atomic Energy Agency (IAEA) was also analyzed. The REE concentration in PG samples was two times higher than those found in national fertilizers, (total of 4,000 mg kg -1 ), 154 times greater than the values found in the sandy soil (26 mg kg -1 ) and 14 times greater than the in clayey soil (280 mg kg -1 ). The experimental results for the reference material were inside the uncertainty of the certified values pointing out the accuracy of the method (95%). The determination of La, Ce, Pr, Nd, Pm, Sm, Eu, Tb, Dy, Ho, Er, Tm, Yb and Lu in the samples and reference material confirmed the versatility of the technique on REE determination in soil and phosphogypsum samples that are matrices for agricultural interest. (author)

  19. Development of analytical techniques for safeguards environmental samples at JAEA

    International Nuclear Information System (INIS)

    Sakurai, Satoshi; Magara, Masaaki; Usuda, Shigekazu; Watanabe, Kazuo; Esaka, Fumitaka; Hirayama, Fumio; Lee, Chi-Gyu; Yasuda, Kenichiro; Inagawa, Jun; Suzuki, Daisuke; Iguchi, Kazunari; Kokubu, Yoko S.; Miyamoto, Yutaka; Ohzu, Akira

    2007-01-01

    JAEA has been developing, under the auspices of the Ministry of Education, Culture, Sports, Science and Technology of Japan, analytical techniques for ultra-trace amounts of nuclear materials in environmental samples in order to contribute to the strengthened safeguards system. Development of essential techniques for bulk and particle analysis, as well as screening, of the environmental swipe samples has been established as ultra-trace analytical methods of uranium and plutonium. In January 2003, JAEA was qualified, including its quality control system, as a member of the JAEA network analytical laboratories for environmental samples. Since 2004, JAEA has conducted the analysis of domestic and the IAEA samples, through which JAEA's analytical capability has been verified and improved. In parallel, advanced techniques have been developed in order to expand the applicability to the samples of various elemental composition and impurities and to improve analytical accuracy and efficiency. This paper summarizes the trace of the technical development in environmental sample analysis at JAEA, and refers to recent trends of research and development in this field. (author)

  20. Water sampling techniques for continuous monitoring of pesticides in water

    Directory of Open Access Journals (Sweden)

    Šunjka Dragana

    2017-01-01

    Full Text Available Good ecological and chemical status of water represents the most important aim of the Water Framework Directive 2000/60/EC, which implies respect of water quality standards at the level of entire river basin (2008/105/EC and 2013/39/EC. This especially refers to the control of pesticide residues in surface waters. In order to achieve the set goals, a continuous monitoring program that should provide a comprehensive and interrelated overview of water status should be implemented. However, it demands the use of appropriate analysis techniques. Until now, the procedure for sampling and quantification of residual pesticide quantities in aquatic environment was based on the use of traditional sampling techniques that imply periodical collecting of individual samples. However, this type of sampling provides only a snapshot of the situation in regard to the presence of pollutants in water. As an alternative, the technique of passive sampling of pollutants in water, including pesticides has been introduced. Different samplers are available for pesticide sampling in surface water, depending on compounds. The technique itself is based on keeping a device in water over a longer period of time which varies from several days to several weeks, depending on the kind of compound. In this manner, the average concentrations of pollutants dissolved in water during a time period (time-weighted average concentrations, TWA are obtained, which enables monitoring of trends in areal and seasonal variations. The use of these techniques also leads to an increase in sensitivity of analytical methods, considering that pre-concentration of analytes takes place within the sorption medium. However, the use of these techniques for determination of pesticide concentrations in real water environments requires calibration studies for the estimation of sampling rates (Rs. Rs is a volume of water per time, calculated as the product of overall mass transfer coefficient and area of

  1. Magnetic separation techniques in sample preparation for biological analysis: a review.

    Science.gov (United States)

    He, Jincan; Huang, Meiying; Wang, Dongmei; Zhang, Zhuomin; Li, Gongke

    2014-12-01

    Sample preparation is a fundamental and essential step in almost all the analytical procedures, especially for the analysis of complex samples like biological and environmental samples. In past decades, with advantages of superparamagnetic property, good biocompatibility and high binding capacity, functionalized magnetic materials have been widely applied in various processes of sample preparation for biological analysis. In this paper, the recent advancements of magnetic separation techniques based on magnetic materials in the field of sample preparation for biological analysis were reviewed. The strategy of magnetic separation techniques was summarized. The synthesis, stabilization and bio-functionalization of magnetic nanoparticles were reviewed in detail. Characterization of magnetic materials was also summarized. Moreover, the applications of magnetic separation techniques for the enrichment of protein, nucleic acid, cell, bioactive compound and immobilization of enzyme were described. Finally, the existed problems and possible trends of magnetic separation techniques for biological analysis in the future were proposed. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. The electron transport problem sampling by Monte Carlo individual collision technique

    International Nuclear Information System (INIS)

    Androsenko, P.A.; Belousov, V.I.

    2005-01-01

    The problem of electron transport is of most interest in all fields of the modern science. To solve this problem the Monte Carlo sampling has to be used. The electron transport is characterized by a large number of individual interactions. To simulate electron transport the 'condensed history' technique may be used where a large number of collisions are grouped into a single step to be sampled randomly. Another kind of Monte Carlo sampling is the individual collision technique. In comparison with condensed history technique researcher has the incontestable advantages. For example one does not need to give parameters altered by condensed history technique like upper limit for electron energy, resolution, number of sub-steps etc. Also the condensed history technique may lose some very important tracks of electrons because of its limited nature by step parameters of particle movement and due to weakness of algorithms for example energy indexing algorithm. There are no these disadvantages in the individual collision technique. This report presents some sampling algorithms of new version BRAND code where above mentioned technique is used. All information on electrons was taken from Endf-6 files. They are the important part of BRAND. These files have not been processed but directly taken from electron information source. Four kinds of interaction like the elastic interaction, the Bremsstrahlung, the atomic excitation and the atomic electro-ionization were considered. In this report some results of sampling are presented after comparison with analogs. For example the endovascular radiotherapy problem (P2) of QUADOS2002 was presented in comparison with another techniques that are usually used. (authors)

  3. Solid Phase Microextraction and Related Techniques for Drugs in Biological Samples

    OpenAIRE

    Moein, Mohammad Mahdi; Said, Rana; Bassyouni, Fatma; Abdel-Rehim, Mohamed

    2014-01-01

    In drug discovery and development, the quantification of drugs in biological samples is an important task for the determination of the physiological performance of the investigated drugs. After sampling, the next step in the analytical process is sample preparation. Because of the low concentration levels of drug in plasma and the variety of the metabolites, the selected extraction technique should be virtually exhaustive. Recent developments of sample handling techniques are directed, from o...

  4. Manipulation of biological samples using micro and nano techniques.

    Science.gov (United States)

    Castillo, Jaime; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    The constant interest in handling, integrating and understanding biological systems of interest for the biomedical field, the pharmaceutical industry and the biomaterial researchers demand the use of techniques that allow the manipulation of biological samples causing minimal or no damage to their natural structure. Thanks to the advances in micro- and nanofabrication during the last decades several manipulation techniques offer us the possibility to image, characterize and manipulate biological material in a controlled way. Using these techniques the integration of biomaterials with remarkable properties with physical transducers has been possible, giving rise to new and highly sensitive biosensing devices. This article reviews the different techniques available to manipulate and integrate biological materials in a controlled manner either by sliding them along a surface (2-D manipulation), by grapping them and moving them to a new position (3-D manipulation), or by manipulating and relocating them applying external forces. The advantages and drawbacks are mentioned together with examples that reflect the state of the art of manipulation techniques for biological samples (171 references).

  5. The electron transport problem sampling by Monte Carlo individual collision technique

    Energy Technology Data Exchange (ETDEWEB)

    Androsenko, P.A.; Belousov, V.I. [Obninsk State Technical Univ. of Nuclear Power Engineering, Kaluga region (Russian Federation)

    2005-07-01

    The problem of electron transport is of most interest in all fields of the modern science. To solve this problem the Monte Carlo sampling has to be used. The electron transport is characterized by a large number of individual interactions. To simulate electron transport the 'condensed history' technique may be used where a large number of collisions are grouped into a single step to be sampled randomly. Another kind of Monte Carlo sampling is the individual collision technique. In comparison with condensed history technique researcher has the incontestable advantages. For example one does not need to give parameters altered by condensed history technique like upper limit for electron energy, resolution, number of sub-steps etc. Also the condensed history technique may lose some very important tracks of electrons because of its limited nature by step parameters of particle movement and due to weakness of algorithms for example energy indexing algorithm. There are no these disadvantages in the individual collision technique. This report presents some sampling algorithms of new version BRAND code where above mentioned technique is used. All information on electrons was taken from Endf-6 files. They are the important part of BRAND. These files have not been processed but directly taken from electron information source. Four kinds of interaction like the elastic interaction, the Bremsstrahlung, the atomic excitation and the atomic electro-ionization were considered. In this report some results of sampling are presented after comparison with analogs. For example the endovascular radiotherapy problem (P2) of QUADOS2002 was presented in comparison with another techniques that are usually used. (authors)

  6. NAIL SAMPLING TECHNIQUE AND ITS INTERPRETATION

    OpenAIRE

    TZAR MN; LEELAVATHI M

    2011-01-01

    The clinical suspicion of onychomyosis based on appearance of the nails, requires culture for confirmation. This is because treatment requires prolonged use of systemic agents which may cause side effects. One of the common problems encountered is improper nail sampling technique which results in loss of essential information. The unfamiliar terminologies used in reporting culture results may intimidate physicians resulting in misinterpretation and hamper treatment decision. This article prov...

  7. Sample preparation techniques for (p, X) spectrometry

    International Nuclear Information System (INIS)

    Whitehead, N.E.

    1985-01-01

    Samples are ashed at low temperature, using oxygen plasma; a rotary evaporator, and freeze drying speeded up the ashing. The new design of apparatus manufactured was only 10 watt but was as efficient as a 200 watt commercial machine; a circuit diagram is included. Samples of hair and biopsy samples of skin were analysed by the technique. A wool standard was prepared for interlaboratory comparison exercises. It was based on New Zealand merino sheep wool and was 2.9 kg in weight. A washing protocol was developed, which preserves most of the trace element content. The wool was ground in liquid nitrogen using a plastic pestle and beaker, driven by a rotary drill press. (author)

  8. Use of an oscillation technique to measure effective cross-sections of fissionable samples in critical assemblies; Mesure des sections efficaces effectives d'echantillons fissiles par une methode d'oscillation dans les-assemblages critiques

    Energy Technology Data Exchange (ETDEWEB)

    Tretiakoff, O; Vidal, R; Carre, J C; Robin, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The authors describe the technique used to measure the effective absorption and neutron-yield cross-sections of a fissionable sample. These two values are determined by analysing the signals due to the variation in reactivity (over-all signal) and the local perturbation in the flux (local signal) produced by the oscillating sample. These signals are standardized by means of a set of samples containing quantities of fissionable material ({sup 235}U) and an absorber, boron, which are well known. The measurements are made for different neutron spectra characterized by lattice parameters which constitute the central zone within which the sample moves. This technique is used to study the effective cross-sections of uranium-plutonium alloys for different heavy-water and graphite lattices in the MINERVE and MARIUS critical assemblies. The same experiments are carried out on fuel samples of different irradiations in order to determine the evolution of effective cross-sections as a function of the spectrum and the irradiations. (authors) [French] On decrit la methode utilisee pour mesurer les sections efficaces effectives d'absorption et de production de neutrons d'un echantillon fissile. Ces deux grandeurs sont determinees en analysant les signaux dus a la variation de reactivite (signal global) et a la perturbation locale de flux (signal local) produits par l'echantillon oscillant. Ces signaux sont etalonnes a l'aide d'un jeu d'echantillons dont les teneurs en materiau fissile ({sup 235}U) et en absorbeur (bore) sont bien connues. Les mesures sont realisees pour differents spectres de neutrons caracterises par les parametres du reseau constituant la zone centrale a l'interieur de laquelle se deplace l'echantillon. A l'aide de cette methode on etudie les sections efficaces effectives d'alliage uranium-plutonium pour differents reseaux a eau lourde et a graphite dans les assemblages crtiques MINERVE et MARIUS. Les memes experiences sont effectuees sur des echantillons de

  9. Former aux TICE : entre compétences techniques et modèles pédagogiques

    Directory of Open Access Journals (Sweden)

    Jacques Béziat

    2012-01-01

    Full Text Available Cette contribution discute des enjeux et des limites d’une formation aux compétences techniques attendues des futurs enseignants d’école primaire. Une formation est certainement nécessaire pour espérer voir des pratiques pédagogiques avec les TICE se développer en classe. Mais ce n’est qu’un des leviers pour leur intégration dans les pratiques scolaires. Une formation aux TICE suppose que l’on mette l’accent sur l’analyse de pratiques. Plus que de former « simplement » à l’usage pédagogique d’outils numériques, il est indispensable de former à la complexité de leurs enjeux intellectuels et pratiques.

  10. Application of the Sampling Selection Technique in Approaching Financial Audit

    Directory of Open Access Journals (Sweden)

    Victor Munteanu

    2018-03-01

    Full Text Available In his professional approach, the financial auditor has a wide range of working techniques, including selection techniques. They are applied depending on the nature of the information available to the financial auditor, the manner in which they are presented - paper or electronic format, and, last but not least, the time available. Several techniques are applied, successively or in parallel, to increase the safety of the expressed opinion and to provide the audit report with a solid basis of information. Sampling is used in the phase of control or clarification of the identified error. The main purpose is to corroborate or measure the degree of risk detected following a pertinent analysis. Since the auditor does not have time or means to thoroughly rebuild the information, the sampling technique can provide an effective response to the need for valorization.

  11. Fluid Sampling under Adverse Conditions Echantillonnage des fluides en conditions difficiles

    Directory of Open Access Journals (Sweden)

    Williams J. M.

    2006-12-01

    Full Text Available Valid samples are essential to the proper description of reservoir fluids; if the samples are not representative, all measurements on them will be invalid. This paper discusses the principal challenges facing fluid sampling including gas condensate reservoirs, compositional gradients, water content of hydrocarbon fluids, asphaltene deposition, wax formation, oil base mud contamination, and reactive components. It also reports the major technological advances recently made in this field. It reviews developments in sampling techniques such as MDT-type tools, new DST sampling tools, coiled tubing sampling, and isokinetic techniques, and it highlights common limitations. The value of making proper use of existing technology is emphasized, both with traditional techniques and new developments, with reference to correct well conditioning, interpretation of field data, and especially to optimum handling of samples. The paper emphasizes the need for better exchange of sampling knowledge between organizations, and highlights the lack of up-to-date industry standards with respect to fluid sampling. A solution is proposed in the form of a joint industry project to identify and document best practices. Des échantillons valables sont essentiels pour bien caractériser les fluides de gisements. Si les échantillons ne sont pas représentatifs, toutes les mesures ultérieures seront entachées d'erreurs. Cet article discute les principaux défis en matière d'échantillonnage, en particulier les réservoirs de gaz à condensats, les gradients compositionnels, la teneur en eau des fluides hydrocarbonés, les dépôts d'asphaltènes, les dépôts de paraffines, la contamination par les boues à base d'huile, et les constituants réactifs. Il relate également les principaux progrès technologiques récemment réalisés dans ce domaine et passe en revue les développements des techniques d'échantillonnage telles que les outils de type MDT, les nouveaux outils d

  12. Administration et gestion des contrats XL

    CERN Document Server

    Senouf, J

    2000-01-01

    Les grands contrats de travaux génèrent un grand nombre de commandes (OSVC) passées par un grand nombre de responsables techniques. Ils sont généralement basés sur des bordereaux de prix associés à un éventail de conditions économiques adaptées aux besoins complexes et variés des multiples utilisateurs du CERN nécessitant des calculs sophistiqués. L'administration des commandes, le suivi des travaux et de la facturation doivent répondre aux besoins de tous les acteurs. Les responsables techniques doivent jouir de la plus large indépendance administrative dans le respect des règlements CERN et des conditions contractuelles. Le contrôle des métrés et décomptes doit être rigoureux et d'une traçabilité complète. L'utilisation des bases de données Oracle a déjà permis l'intégration des données administratives et techniques. Le Web nous invite à une communication totale et transparente entre les utilisateurs, les services techniques et les contractants. De nouveaux types de contrat so...

  13. Nuclear analytical techniques and their application to environmental samples

    International Nuclear Information System (INIS)

    Lieser, K.H.

    1986-01-01

    A survey is given on nuclear analytical techniques and their application to environmental samples. Measurement of the inherent radioactivity of elements or radionuclides allows determination of natural radioelements (e.g. Ra), man-made radioelements (e.g. Pu) and radionuclides in the environment. Activation analysis, in particular instrumental neutron activation analysis, is a very reliable and sensitive method for determination of a great number of trace elements in environmental samples, because the most abundant main constituents are not activated. Tracer techniques are very useful for studies of the behaviour and of chemical reactions of trace elements and compounds in the environment. Radioactive sources are mainly applied for excitation of characteristic X-rays (X-ray fluorescence analysis). (author)

  14. Micro and Nano Techniques for the Handling of Biological Samples

    DEFF Research Database (Denmark)

    Micro and Nano Techniques for the Handling of Biological Samples reviews the different techniques available to manipulate and integrate biological materials in a controlled manner, either by sliding them along a surface (2-D manipulation), or by gripping and moving them to a new position (3-D...

  15. Methodological integrative review of the work sampling technique used in nursing workload research.

    Science.gov (United States)

    Blay, Nicole; Duffield, Christine M; Gallagher, Robyn; Roche, Michael

    2014-11-01

    To critically review the work sampling technique used in nursing workload research. Work sampling is a technique frequently used by researchers and managers to explore and measure nursing activities. However, work sampling methods used are diverse making comparisons of results between studies difficult. Methodological integrative review. Four electronic databases were systematically searched for peer-reviewed articles published between 2002-2012. Manual scanning of reference lists and Rich Site Summary feeds from contemporary nursing journals were other sources of data. Articles published in the English language between 2002-2012 reporting on research which used work sampling to examine nursing workload. Eighteen articles were reviewed. The review identified that the work sampling technique lacks a standardized approach, which may have an impact on the sharing or comparison of results. Specific areas needing a shared understanding included the training of observers and subjects who self-report, standardization of the techniques used to assess observer inter-rater reliability, sampling methods and reporting of outcomes. Work sampling is a technique that can be used to explore the many facets of nursing work. Standardized reporting measures would enable greater comparison between studies and contribute to knowledge more effectively. Author suggestions for the reporting of results may act as guidelines for researchers considering work sampling as a research method. © 2014 John Wiley & Sons Ltd.

  16. Systematic comparison of static and dynamic headspace sampling techniques for gas chromatography.

    Science.gov (United States)

    Kremser, Andreas; Jochmann, Maik A; Schmidt, Torsten C

    2016-09-01

    Six automated, headspace-based sample preparation techniques were used to extract volatile analytes from water with the goal of establishing a systematic comparison between commonly available instrumental alternatives. To that end, these six techniques were used in conjunction with the same gas chromatography instrument for analysis of a common set of volatile organic carbon (VOC) analytes. The methods were thereby divided into three classes: static sampling (by syringe or loop), static enrichment (SPME and PAL SPME Arrow), and dynamic enrichment (ITEX and trap sampling). For PAL SPME Arrow, different sorption phase materials were also included in the evaluation. To enable an effective comparison, method detection limits (MDLs), relative standard deviations (RSDs), and extraction yields were determined and are discussed for all techniques. While static sampling techniques exhibited sufficient extraction yields (approx. 10-20 %) to be reliably used down to approx. 100 ng L(-1), enrichment techniques displayed extraction yields of up to 80 %, resulting in MDLs down to the picogram per liter range. RSDs for all techniques were below 27 %. The choice on one of the different instrumental modes of operation (aforementioned classes) was thereby the most influential parameter in terms of extraction yields and MDLs. Individual methods inside each class showed smaller deviations, and the least influences were observed when evaluating different sorption phase materials for the individual enrichment techniques. The option of selecting specialized sorption phase materials may, however, be more important when analyzing analytes with different properties such as high polarity or the capability of specific molecular interactions. Graphical Abstract PAL SPME Arrow during the extraction of volatile analytes from the headspace of an aqueous sample.

  17. Response to Skinner, et al. on "National personality characteristics: II. Adaption-innovation in Canadian, American, and British samples".

    Science.gov (United States)

    Jenkins, Iwan

    2005-08-01

    Skinner, et al. interpreted as significant the difference between means for Canadian men and women on Kirton's inventory and those for British and American samples. The means were similar to prior values. Skinner, et al.'s groups were large and composed of very unequal numbers of men and women, which factors could account for their interpretation. As reported, their analysis is insufficient to interpret very small mean variations as differences in national character.

  18. Apprentissages techniques pour les professions d'électronicien(ne) et de laborantin(e) en physique - French version only

    CERN Multimedia

    Françoise Benz

    2005-01-01

    HR/PMD APPRENTISSAGES TECHNIQUES GESTION ET DEVELOPPEMENT DU PERSONNEL L'APPRENTISSAGE AU CERN Pour les professions d'électronicien(ne) et de laborantin(e) en physique L'apprentissage au CERN est régi par les lois, règlements et contrats en vigueur dans le Canton de Genève. En cas de réussite à l'examen de fin d'apprentissage, les apprentis obtiennent le Certificat Fédéral de Capacité Suisse (CFC). 7 places au total sont ouvertes au recrutement pour les deux professions. L'apprentissage dure 4 ans. Minima requis pour faire acte de candidature : avoir au moins 15 ans et moins de 21 ans à la date de début de l'apprentissage avoir terminé la scolarité obligatoire, au minimum 9e du Cycle d'orientation genevois (3e en France) être ressortissant d'un pays membre du CERN (Allemagne, Autriche, Belgique, Bulgarie, Danemark, Espagne, Finlande, France, Gr&am...

  19. RF Sub-sampling Receiver Architecture based on Milieu Adapting Techniques

    DEFF Research Database (Denmark)

    Behjou, Nastaran; Larsen, Torben; Jensen, Ole Kiel

    2012-01-01

    A novel sub-sampling based architecture is proposed which has the ability of reducing the problem of image distortion and improving the signal to noise ratio significantly. The technique is based on sensing the environment and adapting the sampling rate of the receiver to the best possible...

  20. Improved importance sampling technique for efficient simulation of digital communication systems

    Science.gov (United States)

    Lu, Dingqing; Yao, Kung

    1988-01-01

    A new, improved importance sampling (IIS) approach to simulation is considered. Some basic concepts of IS are introduced, and detailed evolutions of simulation estimation variances for Monte Carlo (MC) and IS simulations are given. The general results obtained from these evolutions are applied to the specific previously known conventional importance sampling (CIS) technique and the new IIS technique. The derivation for a linear system with no signal random memory is considered in some detail. For the CIS technique, the optimum input scaling parameter is found, while for the IIS technique, the optimum translation parameter is found. The results are generalized to a linear system with memory and signals. Specific numerical and simulation results are given which show the advantages of CIS over MC and IIS over CIS for simulations of digital communications systems.

  1. Cone penetrometer tests and HydroPunch sampling: A screening technique for plume definition

    International Nuclear Information System (INIS)

    Smolley, M.; Kappmeyer, J.C.

    1991-01-01

    Cone penetrometer tests and HydroPunch sampling were used to define the extent of volatile organic compounds in ground water. The investigation indicated that the combination of the these techniques is effective for obtaining ground water samples for preliminary plume definition. HydroPunch samples can be collected in unconsolidated sediments and the analytical results obtained from these samples are comparable to those obtained from adjacent monitoring wells. This sampling method is a rapid and cost-effective screening technique for characterizing the extent of contaminant plumes in soft sediment environments. Use of this screening technique allowed monitoring wells to be located at the plume boundary, thereby reducing the number of wells installed and the overall cost of the plume definition program

  2. Chance constrained problems: penalty reformulation and performance of sample approximation technique

    Czech Academy of Sciences Publication Activity Database

    Branda, Martin

    2012-01-01

    Roč. 48, č. 1 (2012), s. 105-122 ISSN 0023-5954 R&D Projects: GA ČR(CZ) GBP402/12/G097 Institutional research plan: CEZ:AV0Z10750506 Keywords : chance constrained problems * penalty functions * asymptotic equivalence * sample approximation technique * investment problem Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.619, year: 2012 http://library.utia.cas.cz/separaty/2012/E/branda-chance constrained problems penalty reformulation and performance of sample approximation technique.pdf

  3. Sampling methods and non-destructive examination techniques for large radioactive waste packages

    International Nuclear Information System (INIS)

    Green, T.H.; Smith, D.L.; Burgoyne, K.E.; Maxwell, D.J.; Norris, G.H.; Billington, D.M.; Pipe, R.G.; Smith, J.E.; Inman, C.M.

    1992-01-01

    Progress is reported on work undertaken to evaluate quality checking methods for radioactive wastes. A sampling rig was designed, fabricated and used to develop techniques for the destructive sampling of cemented simulant waste using remotely operated equipment. An engineered system for the containment of cooling water was designed and manufactured and successfully demonstrated with the drum and coring equipment mounted in both vertical and horizontal orientations. The preferred in-cell orientation was found to be with the drum and coring machinery mounted in a horizontal position. Small powdered samples can be taken from cemented homogeneous waste cores using a hollow drill/vacuum section technique with the preferred subsampling technique being to discard the outer 10 mm layer to obtain a representative sample of the cement core. Cement blends can be dissolved using fusion techniques and the resulting solutions are stable to gelling for periods in excess of one year. Although hydrochloric acid and nitric acid are promising solvents for dissolution of cement blends, the resultant solutions tend to form silicic acid gels. An estimate of the beta-emitter content of cemented waste packages can be obtained by a combination of non-destructive and destructive techniques. The errors will probably be in excess of +/-60 % at the 95 % confidence level. Real-time X-ray video-imaging techniques have been used to analyse drums of uncompressed, hand-compressed, in-drum compacted and high-force compacted (i.e. supercompacted) simulant waste. The results have confirmed the applicability of this technique for NDT of low-level waste. 8 refs., 12 figs., 3 tabs

  4. A Comparison of Soil-Water Sampling Techniques

    Science.gov (United States)

    Tindall, J. A.; Figueroa-Johnson, M.; Friedel, M. J.

    2007-12-01

    The representativeness of soil pore water extracted by suction lysimeters in ground-water monitoring studies is a problem that often confounds interpretation of measured data. Current soil water sampling techniques cannot identify the soil volume from which a pore water sample is extracted, neither macroscopic, microscopic, or preferential flowpath. This research was undertaken to compare values of extracted suction lysimeters samples from intact soil cores with samples obtained by the direct extraction methods to determine what portion of soil pore water is sampled by each method. Intact soil cores (30 centimeter (cm) diameter by 40 cm height) were extracted from two different sites - a sandy soil near Altamonte Springs, Florida and a clayey soil near Centralia in Boone County, Missouri. Isotopically labeled water (O18? - analyzed by mass spectrometry) and bromide concentrations (KBr- - measured using ion chromatography) from water samples taken by suction lysimeters was compared with samples obtained by direct extraction methods of centrifugation and azeotropic distillation. Water samples collected by direct extraction were about 0.25 ? more negative (depleted) than that collected by suction lysimeter values from a sandy soil and about 2-7 ? more negative from a well structured clayey soil. Results indicate that the majority of soil water in well-structured soil is strongly bound to soil grain surfaces and is not easily sampled by suction lysimeters. In cases where a sufficient volume of water has passed through the soil profile and displaced previous pore water, suction lysimeters will collect a representative sample of soil pore water from the sampled depth interval. It is suggested that for stable isotope studies monitoring precipitation and soil water, suction lysimeter should be installed at shallow depths (10 cm). Samples should also be coordinated with precipitation events. The data also indicate that each extraction method be use to sample a different

  5. Can groundwater sampling techniques used in monitoring wells influence methane concentrations and isotopes?

    Science.gov (United States)

    Rivard, Christine; Bordeleau, Geneviève; Lavoie, Denis; Lefebvre, René; Malet, Xavier

    2018-03-06

    Methane concentrations and isotopic composition in groundwater are the focus of a growing number of studies. However, concerns are often expressed regarding the integrity of samples, as methane is very volatile and may partially exsolve during sample lifting in the well and transfer to sampling containers. While issues concerning bottle-filling techniques have already been documented, this paper documents a comparison of methane concentration and isotopic composition obtained with three devices commonly used to retrieve water samples from dedicated observation wells. This work lies within the framework of a larger project carried out in the Saint-Édouard area (southern Québec, Canada), whose objective was to assess the risk to shallow groundwater quality related to potential shale gas exploitation. The selected sampling devices, which were tested on ten wells during three sampling campaigns, consist of an impeller pump, a bladder pump, and disposable sampling bags (HydraSleeve). The sampling bags were used both before and after pumping, to verify the appropriateness of a no-purge approach, compared to the low-flow approach involving pumping until stabilization of field physicochemical parameters. Results show that methane concentrations obtained with the selected sampling techniques are usually similar and that there is no systematic bias related to a specific technique. Nonetheless, concentrations can sometimes vary quite significantly (up to 3.5 times) for a given well and sampling event. Methane isotopic composition obtained with all sampling techniques is very similar, except in some cases where sampling bags were used before pumping (no-purge approach), in wells where multiple groundwater sources enter the borehole.

  6. The thin layer technique and its application to electron microscopy; La technique des couches minces et son application a la microscopie electronique

    Energy Technology Data Exchange (ETDEWEB)

    Ranc, G. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-10-15

    This work deals with the technique of thin layers obtained by evaporation under vacuum, in the thickness range extending from a few monoatomic layers to several hundred angstroms. The great theoretical and practical interest of these layers has, it is well known, given rise to many investigations from Faraday onwards. Within the necessarily restricted limits of this study, we shall approach the problem more particularly from the point of view of: - their production; - their use in electron microscopy. A critical appraisal is made, in the light of present-day knowledge, based on our personal experience and on an extensive bibliography which we have collected on the subject. (author) [French] Le present travail concerne la technique des couches minces obtenues par evaporation sous vide, dans le domaine d'epaisseur qui s'etend de quelques couches monoatomiques a plusieurs centaines d'angstroms. L'interet theorique et pratique considerable de ces couches a suscite, comme on sait, de nombreux travaux depuis Faraday. Dans le cadre necessairement restreint de cette these, nous aborderons plus particulierement le point de vue de: - leur obtention; - leur utilisation en microscopie electronique. Il s'agit d'une mise au point critique, a la lumiere des connaissances actuelles, appuyee sur notre experience personnelle et sur une importante bibliographie, qu'il nous a ete donne de reunir a ce sujet. (auteur)

  7. The thin layer technique and its application to electron microscopy; La technique des couches minces et son application a la microscopie electronique

    Energy Technology Data Exchange (ETDEWEB)

    Ranc, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-10-15

    This work deals with the technique of thin layers obtained by evaporation under vacuum, in the thickness range extending from a few monoatomic layers to several hundred angstroms. The great theoretical and practical interest of these layers has, it is well known, given rise to many investigations from Faraday onwards. Within the necessarily restricted limits of this study, we shall approach the problem more particularly from the point of view of: - their production; - their use in electron microscopy. A critical appraisal is made, in the light of present-day knowledge, based on our personal experience and on an extensive bibliography which we have collected on the subject. (author) [French] Le present travail concerne la technique des couches minces obtenues par evaporation sous vide, dans le domaine d'epaisseur qui s'etend de quelques couches monoatomiques a plusieurs centaines d'angstroms. L'interet theorique et pratique considerable de ces couches a suscite, comme on sait, de nombreux travaux depuis Faraday. Dans le cadre necessairement restreint de cette these, nous aborderons plus particulierement le point de vue de: - leur obtention; - leur utilisation en microscopie electronique. Il s'agit d'une mise au point critique, a la lumiere des connaissances actuelles, appuyee sur notre experience personnelle et sur une importante bibliographie, qu'il nous a ete donne de reunir a ce sujet. (auteur)

  8. L’Afrique et l’histoire des techniques. Hommage à François Sigaut Africa and the history of techniques. Tribute to François Sigaut

    Directory of Open Access Journals (Sweden)

    Monique Chastanet

    2013-02-01

    Full Text Available Spécialiste de l’histoire et de l’anthropologie des techniques des sociétés préindustrielles, dans le domaine de l’agriculture et de l’alimentation, François Sigaut (10 novembre 1940 – 2 novembre 2012 nous a quittés récemment, emporté en deux mois par un cancer, alors qu’il avait encore de nombreux travaux en chantier. Ses recherches étaient centrées sur l’Europe, mais il s’intéressait également aux autres continents, à l’Afrique en particulier. Cet intérêt était lié à sa démarche comparativ...

  9. Development of environmental sample analysis techniques for safeguards

    International Nuclear Information System (INIS)

    Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka

    1999-01-01

    JAERI has been developing environmental sample analysis techniques for safeguards and preparing a clean chemistry laboratory with clean rooms. Methods to be developed are a bulk analysis and a particle analysis. In the bulk analysis, Inductively-Coupled Plasma Mass Spectrometer or Thermal Ionization Mass Spectrometer are used to measure nuclear materials after chemical treatment of sample. In the particle analysis, Electron Probe Micro Analyzer and Secondary Ion Mass Spectrometer are used for elemental analysis and isotopic analysis, respectively. The design of the clean chemistry laboratory has been carried out and construction will be completed by the end of March, 2001. (author)

  10. Study of heterogeneous multiplying and non-multiplying media by the neutron pulsed source technique; Etude des milieux heterogenes multiplicateurs et non-multiplicateurs par la technique de la source pulsee de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Deniz, V [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-06-01

    The pulsed neutron technique consists essentially in sending in the medium to be studied a short neutron pulse and in determining the asymptotic decay constant of the generated population. The variation of the decay constant as a function of the size of the medium allows the medium characteristics to be defined. This technique has been largely developed these last years and has been applied as well to moderator as to multiplying media, in most cases homogeneous ones. We considered of interest of apply this technique to lattices, to see if useful informations could be collected for lattice calculations. We present here a general theoretical study of the problem, and results and interpretation of a series of experiments made on graphite lattices. There is a good agreement for non-multiplying media. In the case of multiplying media, it is shown that the age value used until now in graphite lattices calculations is over-estimated by about 10 per cent. [French] La technique de la pulsation neutronique consiste essentiellement a envoyer dans le milieu a etudier une courte bouffee de neutrons et a determiner la constante de decroissance asymptotique de la population engendree. La variation de cette constante de decroissance en fonction des dimensions du milieu permet de determiner ses caracteristiques. Cette technique a connu ces dernieres annees un grand essor et a ete appliquee a des moderateurs et des milieux multiplicateurs. Il s'agissait dans la plupart des cas de milieux homogenes. Il nous a semble interessant de l'utiliser dans le cas des reseaux, afin de voir si ces experiences peuvent fournir des renseignements utiles aux calculs. Nous presentons ici une etude theorique generale du probleme, ainsi que les resultats et l'interpretation d'une serie d'experiences faites sur des reseaux a graphite. L'accord est bon dans le cas des reseaux non-multiplicateurs. Dans le cas des reseaux multiplicateurs, on montre que la valeur de l'age utilisee jusqu'ici dans les calculs

  11. Standardization of proton-induced x-ray emission technique for analysis of thick samples

    Science.gov (United States)

    Ali, Shad; Zeb, Johar; Ahad, Abdul; Ahmad, Ishfaq; Haneef, M.; Akbar, Jehan

    2015-09-01

    This paper describes the standardization of the proton-induced x-ray emission (PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials (SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 MeV obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.

  12. Review of sample preparation techniques for the analysis of pesticide residues in soil.

    Science.gov (United States)

    Tadeo, José L; Pérez, Rosa Ana; Albero, Beatriz; García-Valcárcel, Ana I; Sánchez-Brunete, Consuelo

    2012-01-01

    This paper reviews the sample preparation techniques used for the analysis of pesticides in soil. The present status and recent advances made during the last 5 years in these methods are discussed. The analysis of pesticide residues in soil requires the extraction of analytes from this matrix, followed by a cleanup procedure, when necessary, prior to their instrumental determination. The optimization of sample preparation is a very important part of the method development that can reduce the analysis time, the amount of solvent, and the size of samples. This review considers all aspects of sample preparation, including extraction and cleanup. Classical extraction techniques, such as shaking, Soxhlet, and ultrasonic-assisted extraction, and modern techniques like pressurized liquid extraction, microwave-assisted extraction, solid-phase microextraction and QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) are reviewed. The different cleanup strategies applied for the purification of soil extracts are also discussed. In addition, the application of these techniques to environmental studies is considered.

  13. Les déchets électroniques et informatiques en Afrique : Défis et ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    environnement, Faculté des sciences et techniques, Université Cheikh Anta Diop de Dakar, Sénégal, et coordonnateur régional du projet « É-déchets ». Ramata Molo Thioune, chercheure, économiste/environnementaliste, ...

  14. Laboratory techniques for safe encapsulation of α-emitting powder samples

    International Nuclear Information System (INIS)

    Chamberlain, H.E.; Pottinger, J.S.

    1984-01-01

    Plutonium oxide powder samples can be encapsulated in thin plastic film to prevent spread of contamination in counting and X-ray diffraction equipment. The film has to be thin enough to transmit X-rays and α-particles. Techniques are described for the wrapping process and the precautions necessary to keep the sample processing line free of significant contamination. (author)

  15. Sampling phased array a new technique for signal processing and ultrasonic imaging

    OpenAIRE

    Bulavinov, A.; Joneit, D.; Kröning, M.; Bernus, L.; Dalichow, M.H.; Reddy, K.M.

    2006-01-01

    Different signal processing and image reconstruction techniques are applied in ultrasonic non-destructive material evaluation. In recent years, rapid development in the fields of microelectronics and computer engineering lead to wide application of phased array systems. A new phased array technique, called "Sampling Phased Array" has been developed in Fraunhofer Institute for non-destructive testing. It realizes unique approach of measurement and processing of ultrasonic signals. The sampling...

  16. The role of graphene-based sorbents in modern sample preparation techniques.

    Science.gov (United States)

    de Toffoli, Ana Lúcia; Maciel, Edvaldo Vasconcelos Soares; Fumes, Bruno Henrique; Lanças, Fernando Mauro

    2018-01-01

    The application of graphene-based sorbents in sample preparation techniques has increased significantly since 2011. These materials have good physicochemical properties to be used as sorbent and have shown excellent results in different sample preparation techniques. Graphene and its precursor graphene oxide have been considered to be good candidates to improve the extraction and concentration of different classes of target compounds (e.g., parabens, polycyclic aromatic hydrocarbon, pyrethroids, triazines, and so on) present in complex matrices. Its applications have been employed during the analysis of different matrices (e.g., environmental, biological and food). In this review, we highlight the most important characteristics of graphene-based material, their properties, synthesis routes, and the most important applications in both off-line and on-line sample preparation techniques. The discussion of the off-line approaches includes methods derived from conventional solid-phase extraction focusing on the miniaturized magnetic and dispersive modes. The modes of microextraction techniques called stir bar sorptive extraction, solid phase microextraction, and microextraction by packed sorbent are discussed. The on-line approaches focus on the use of graphene-based material mainly in on-line solid phase extraction, its variation called in-tube solid-phase microextraction, and on-line microdialysis systems. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Techniques of sample attack used in soil and mineral analysis. Phase I

    International Nuclear Information System (INIS)

    Chiu, N.W.; Dean, J.R.; Sill, C.W.

    1984-07-01

    Several techniques of sample attack for the determination of radioisotopes are reviewed. These techniques include: 1) digestion with nitric or hydrochloric acid in Parr digestion bomb, 2) digestion with a mixture of nitric and hydrochloric acids, 3) digestion with a mixture of hydrofluoric, nitric and perchloric acids, and 4) fusion with sodium carbonate, potassium fluoride or alkali pyrosulfates. The effectiveness of these techniques to decompose various soils and minerals containing radioisotopes such as lead-210 uranium, thorium and radium-226 are discussed. The combined procedure of potassium fluoride fusion followed by alkali pyrosulfate fusion is recommended for radium-226, uranium and thorium analysis. This technique guarantees the complete dissolution of samples containing refractory materials such as silica, silicates, carbides, oxides and sulfates. For the lead-210 analysis, the procedure of digestion with a mixture of hydrofluoric, nitric and perchloric acids followed by fusion with alkali pyrosulfate is recommended. These two procedures are detailed. Schemes for the sequential separation of the radioisotopes from a dissolved sample solution are outlined. Procedures for radiochemical analysis are suggested

  18. Assessment of Natural Radioactivity in TENORM Samples Using Different Techniques

    International Nuclear Information System (INIS)

    Salman, Kh.A.; Shahein, A.Y.

    2009-01-01

    In petroleum oil industries, technologically-enhanced, naturally occurring radioactive materials are produced. The presence of TENORM constitutes a significant radiological human health hazard. In the present work, liquid scintillation counting technique was used to determine both 222 Rn and 226 Ra concentrations in TENORM samples, by measuring 222 Rn concentrations in the sample at different intervals of time after preparation. The radiation doses from the TENORM samples were estimated using thermoluminenscent detector (TLD-4000). The estimated radiation doses were found to be proportional to both the measured radiation doses in site and natural activity concentration in the samples that measured with LSC

  19. Omotayo et al (4)

    African Journals Online (AJOL)

    DELL

    using biochemical technique and API 20E identification system. The isolates were .... sulphate, phosphate, ammonia and appearance. Heavy metals ... technique as described by Collee et al. (1989) was ..... enzymatic methods. Water Res. 36,.

  20. Review of online coupling of sample preparation techniques with liquid chromatography.

    Science.gov (United States)

    Pan, Jialiang; Zhang, Chengjiang; Zhang, Zhuomin; Li, Gongke

    2014-03-07

    Sample preparation is still considered as the bottleneck of the whole analytical procedure, and efforts has been conducted towards the automation, improvement of sensitivity and accuracy, and low comsuption of organic solvents. Development of online sample preparation techniques (SP) coupled with liquid chromatography (LC) is a promising way to achieve these goals, which has attracted great attention. This article reviews the recent advances on the online SP-LC techniques. Various online SP techniques have been described and summarized, including solid-phase-based extraction, liquid-phase-based extraction assisted with membrane, microwave assisted extraction, ultrasonic assisted extraction, accelerated solvent extraction and supercritical fluids extraction. Specially, the coupling approaches of online SP-LC systems and the corresponding interfaces have been discussed and reviewed in detail, such as online injector, autosampler combined with transport unit, desorption chamber and column switching. Typical applications of the online SP-LC techniques have been summarized. Then the problems and expected trends in this field are attempted to be discussed and proposed in order to encourage the further development of online SP-LC techniques. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Cleaning and Cleanliness Verification Techniques for Mars Returned Sample Handling

    Science.gov (United States)

    Mickelson, E. T.; Lindstrom, D. J.; Allton, J. H.; Hittle, J. D.

    2002-01-01

    Precision cleaning and cleanliness verification techniques are examined as a subset of a comprehensive contamination control strategy for a Mars sample return mission. Additional information is contained in the original extended abstract.

  2. Les sciences humaines dans les parcours scientifiques et techniques professionnalisants : quelles finalités et quelles modalités pratiques ? Présentation générale 

    Directory of Open Access Journals (Sweden)

    Bernard Comité éditorial : Alain

    2014-01-01

    Full Text Available Cette introduction a été rédigée par les membres du comité éditorial, également membres du groupe « Sciences et Techniques en interférences » 1 de l'Université Paris-Est-Créteil (UPEC. Elle décrit d'abord l'origine de ce volume collectif, le contexte institutionnel et de recherche des questions qui y sont soulevées. Elle présente le mode de composition du recueil, notamment la manière dont la répartition thématique des différentes contributions a été obtenue. Ensuite, cinq parties correspondant aux cinq sections du volume introduisent les contributions qui y ont été rassemblées en soulignant, lorsqu'il y a lieu, les thématiques communes et les champs concernés. La première partie, Etudes comparatistes, renvoie à des études globales au niveau français ou européen. Elle est complétée par la seconde, Influence du contexte local, qui présente des études de cas plus localisées et focalisées sur l'importance du contexte institutionnel. La partie suivante, Dispositif pédagogiques, présente d'autres études de cas qui problématisent principalement l'ingénierie pédagogique mise en œuvre. La quatrième partie, Formation et Recherche, s'intéresse à trois modes originaux d'articulation entre formation professionnelle et initiation à la recherche. Enfin la dernière partie, Fondements et Enjeux, rassemble des contributions à caractère philosophique, sociologique et historique interrogeant les enjeux fondamentaux sous-jacents à la conception des formations qui font l'objet du volume.

  3. Etat actuel et avenir de l'industrie pétrolière d'extraction. Exposés présentés lors de la journée d'ouverture et la séance de clôture du Colloque international sur les Techniques d'Exploration et d'Exploitation des Hydrocarbures. Paris, 10-12 décembre 1975 Present State and Future of the Petroleum Extraction Industry. Talk Presented During the Opening Day and the Closing Session of the International Symposium on Hydrocarbon Exploration, Drilling and Production Techniques. Paris, 10-12 December 1975

    Directory of Open Access Journals (Sweden)

    Piketti G.

    2006-11-01

    Full Text Available Ce document reprend les exposés et les discussions qui ont suivi, présentés lors de la journée d'ouverture et la séance de clôture du Colloque International sur les Techniques d'Exploration et d'Exploitation des Hydrocarbures organisé à Paris du 10 au 12 décembre 1975 par l'Association de Recherche sur les Techniques d'Exploitation du Pétrole (ARTEP et le Comité d'Études Pétrolières Marines (CEPM. Les communications techniques de ce colloque ont été publiées dans deux ouvrages(' consacrés respectivement - à l'exploitation des gisements. Méthodes de récupération assistée. Techniques de production ; - et au forage et à la production en mers profondes. This article contains the talks and ensuing discussions presented during the opening day and the closing session of the International Symposium on Hydrocarbon Exploration, Drilling and Production Techniques organized in Paris from 10 ta 12 December 1975 by the Association de Recherche sur les Techniques d'Exploitation du Pétrole (ARTEP and the Comité d'Études Pétrolières Marines (CEPM. The technical papers presented at this symposium have been published in two volumes (2 on the following respective topics - Reservoir Engineering. Enhanced Recovery Methods. Production Techniques; - Drilling and Production in Deep Water.

  4. THE STUDY OF HEAVY METAL FROM ENVIRONMENTAL SAMPLES BY ATOMIC TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Ion V. POPESCU

    2011-05-01

    Full Text Available Using the Atomic Absorption Spectrometry (AAS and Energy Dispersive X-ray spectrometry (EDXRF techniques we analyzed the contents of heavy metals ( Cd, Cr, Ni, Pb, Ti, Sr, Co, Bi from eight wild mushrooms and soil substrate samples (48 samples of eight fungal species and 32 underlying soil samples, collected from ten forest sites of Dambovița County Romania. It was determined that the elements, especially heavy metals, in soil were characteristic of the acidic soils of the Romanian forest lands and are influenced by industrial pollution. Analytical possibilities of AAS and EDXRF analytical techniques have been compared and the heavy metal transfer from substrate to mushrooms has been studied. The coefficient of accumulation of essential and heavy metals has been calculated as well. Heavy metal contents of all analyzed mushrooms were generally higher than previously reported in literature.

  5. Comparison between correlated sampling and the perturbation technique of MCNP5 for fixed-source problems

    International Nuclear Information System (INIS)

    He Tao; Su Bingjing

    2011-01-01

    Highlights: → The performance of the MCNP differential operator perturbation technique is compared with that of the MCNP correlated sampling method for three types of fixed-source problems. → In terms of precision, the MCNP perturbation technique outperforms correlated sampling for one type of problem but performs comparably with or even under-performs correlated sampling for the other two types of problems. → In terms of accuracy, the MCNP perturbation calculations may predict inaccurate results for some of the test problems. However, the accuracy can be improved if the midpoint correction technique is used. - Abstract: Correlated sampling and the differential operator perturbation technique are two methods that enable MCNP (Monte Carlo N-Particle) to simulate small response change between an original system and a perturbed system. In this work the performance of the MCNP differential operator perturbation technique is compared with that of the MCNP correlated sampling method for three types of fixed-source problems. In terms of precision of predicted response changes, the MCNP perturbation technique outperforms correlated sampling for the problem involving variation of nuclide concentrations in the same direction but performs comparably with or even underperforms correlated sampling for the other two types of problems that involve void or variation of nuclide concentrations in opposite directions. In terms of accuracy, the MCNP differential operator perturbation calculations may predict inaccurate results that deviate from the benchmarks well beyond their uncertainty ranges for some of the test problems. However, the accuracy of the MCNP differential operator perturbation can be improved if the midpoint correction technique is used.

  6. A technique for extracting blood samples from mice in fire toxicity tests

    Science.gov (United States)

    Bucci, T. J.; Hilado, C. J.; Lopez, M. T.

    1976-01-01

    The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.

  7. Comparison of sampling techniques for Rift Valley Fever virus ...

    African Journals Online (AJOL)

    We investigated mosquito sampling techniques with two types of traps and attractants at different time for trapping potential vectors for Rift Valley Fever virus. The study was conducted in six villages in Ngorongoro district in Tanzania from September to October 2012. A total of 1814 mosquitoes were collected, of which 738 ...

  8. Fiche technique du spermogramme et du spermocytogramme ...

    African Journals Online (AJOL)

    En Afrique la stérilité du couple constitue un drame social. Selon l'OMS, environ 8 à 12 % des couples africains sont touchés par une infertilité. La responsabilité masculine dans la stérilité est comprise entre 30 à 40%. Les causes de l'infertilité masculine peuvent être l'impuissance et/ ou l'altération du sperme. L'étude de ...

  9. A line-based vegetation sampling technique and its application in ...

    African Journals Online (AJOL)

    percentage cover, density and intercept frequency) and also provides plant size distributions, yet requires no more sampling effort than the line-intercept method.. A field test of the three techniques in succulent karoo, showed that the discriminating ...

  10. Comparison of correlation analysis techniques for irregularly sampled time series

    Directory of Open Access Journals (Sweden)

    K. Rehfeld

    2011-06-01

    Full Text Available Geoscientific measurements often provide time series with irregular time sampling, requiring either data reconstruction (interpolation or sophisticated methods to handle irregular sampling. We compare the linear interpolation technique and different approaches for analyzing the correlation functions and persistence of irregularly sampled time series, as Lomb-Scargle Fourier transformation and kernel-based methods. In a thorough benchmark test we investigate the performance of these techniques.

    All methods have comparable root mean square errors (RMSEs for low skewness of the inter-observation time distribution. For high skewness, very irregular data, interpolation bias and RMSE increase strongly. We find a 40 % lower RMSE for the lag-1 autocorrelation function (ACF for the Gaussian kernel method vs. the linear interpolation scheme,in the analysis of highly irregular time series. For the cross correlation function (CCF the RMSE is then lower by 60 %. The application of the Lomb-Scargle technique gave results comparable to the kernel methods for the univariate, but poorer results in the bivariate case. Especially the high-frequency components of the signal, where classical methods show a strong bias in ACF and CCF magnitude, are preserved when using the kernel methods.

    We illustrate the performances of interpolation vs. Gaussian kernel method by applying both to paleo-data from four locations, reflecting late Holocene Asian monsoon variability as derived from speleothem δ18O measurements. Cross correlation results are similar for both methods, which we attribute to the long time scales of the common variability. The persistence time (memory is strongly overestimated when using the standard, interpolation-based, approach. Hence, the Gaussian kernel is a reliable and more robust estimator with significant advantages compared to other techniques and suitable for large scale application to paleo-data.

  11. Application of nuclear and allied techniques for the characterisation of forensic samples

    International Nuclear Information System (INIS)

    Sudersanan, M.; Kayasth, S.R.; Pant, D.R.; Chattopadhyay, N.; Bhattacharyya, C.N.

    2002-01-01

    Full text: Forensic science deals with the application of various techniques for physics, chemistry and biology for crime investigation. The legal implication of such analysis put considerable restriction on the choice of analytical techniques. Moreover, the unknown nature of the materials, the limited availability of samples and the large number of elements to be analysed put considerable strain on the analytical chemist on the selection of the appropriate technique. The availability of nuclear techniques has considerably enhanced the scope of forensic analysis. This paper deals with the recent results on the use of nuclear and allied analytical techniques for forensic applications. One of the important types of samples of forensic importance pertain to the identification of gunshot residues. The use of nuclear techniques has considerably simplified the interpretation of results through the use of appropriate elements like Ba, Cu, Sb, Zn, As and Sn etc. The combination of non-nuclear techniques for elements like Pb and Ni which are not easily amenable to be analysed by NAA and the use of appropriate separation procedure has led to the use of this method as a valid and versatile analytical procedure. In view of the presence of a large amounts of extraneous materials like cloth, body tissues etc in these samples and the limited availability of materials, the procedures for sample collection, dissolution and analysis have been standardized. Analysis of unknown materials like powders, metallic pieces etc. for the possible presence of nuclear materials or as materials in illicit trafficking is becoming important in recent years. The use of multi-technique approach is important in this case. Use of non-destructive techniques like XRF and radioactive counting enables the preliminary identification of materials and for the detection of radioactivity. Subsequent analysis by NAA or other appropriate analytical methods allows the characterization of the materials. Such

  12. Le cheval, le cavalier et l’hippocentaure. Technique équestre, éthique et métaphore politique chez Xénophon

    Directory of Open Access Journals (Sweden)

    Alexandre Blaineau

    2010-04-01

    Full Text Available À l’épreuve du politique, la figure du centaure agit comme un réactif. La dualité de son être, la réunion des contraires, la fusion de la nature et de la culture, l’intrication de la bestialité et de la sagesse, de l’instinct et du raisonnement, de la démesure et de la mesure, composent un être bon à penser symboliquement, particulièrement pour les théoriciens du pouvoir. Ainsi dans Le Prince (XVIII, Machiavel prend-il comme exemple Chiron, qui enseigne à ses élèves la duplicité et l’usage d...

  13. Revue d'Information Scientifique et Technique - Vol 2, No 1 (1992)

    African Journals Online (AJOL)

    Société d'lnformation Innovations Technologiques et système d'information et de communication scientifique · EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. L Ydroudj ...

  14. Determination of palladium in biological samples applying nuclear analytical techniques

    International Nuclear Information System (INIS)

    Cavalcante, Cassio Q.; Sato, Ivone M.; Salvador, Vera L. R.; Saiki, Mitiko

    2008-01-01

    This study presents Pd determinations in bovine tissue samples containing palladium prepared in the laboratory, and CCQM-P63 automotive catalyst materials of the Proficiency Test, using instrumental thermal and epithermal neutron activation analysis and energy dispersive X-ray fluorescence techniques. Solvent extraction and solid phase extraction procedures were also applied to separate Pd from interfering elements before the irradiation in the nuclear reactor. The results obtained by different techniques were compared against each other to examine sensitivity, precision and accuracy. (author)

  15. A new sampling technique for surface exposure dating using a portable electric rock cutter

    Directory of Open Access Journals (Sweden)

    Yusuke Suganuma

    2012-07-01

    Full Text Available Surface exposure dating using in situ cosmogenic nuclides has contributed to our understanding of Earth-surface processes. The precision of the ages estimated by this method is affected by the sample geometry; therefore, high accuracy measurements of the thickness and shape of the rock sample (thickness and shape is crucial. However, it is sometimes diffi cult to meet these requirements by conventional sampling methods with a hammer and chisel. Here, we propose a new sampling technique using a portable electric rock cutter. This sampling technique is faster, produces more precisely shaped samples, and allows for a more precise age interpretation. A simple theoretical modeldemonstrates that the age error due to defective sample geometry increases as the total sample thickness increases, indicating the importance of precise sampling for surface exposure dating.

  16. Mantle biopsy: a technique for nondestructive tissue-sampling of freshwater mussels

    Science.gov (United States)

    David J. Berg; Wendell R. Haag; Sheldon I. Guttman; James B. Sickel

    1995-01-01

    Mantle biopsy is a means of obtaining tissue samples for genetic, physiological, and contaminant studies of bivalves; but the effects of this biopsy on survival have not been determined. We describe a simple technique for obtaining such samples from unionacean bivalves and how we compared survival among biopsied and control organisms in field experiments. Survival was...

  17. A Monte Carlo Sampling Technique for Multi-phonon Processes

    Energy Technology Data Exchange (ETDEWEB)

    Hoegberg, Thure

    1961-12-15

    A sampling technique for selecting scattering angle and energy gain in Monte Carlo calculations of neutron thermalization is described. It is supposed that the scattering is separated into processes involving different numbers of phonons. The number of phonons involved is first determined. Scattering angle and energy gain are then chosen by using special properties of the multi-phonon term.

  18. Evaluation of primary immunization coverage of infants under universal immunization programme in an urban area of bangalore city using cluster sampling and lot quality assurance sampling techniques.

    Science.gov (United States)

    K, Punith; K, Lalitha; G, Suman; Bs, Pradeep; Kumar K, Jayanth

    2008-07-01

    Is LQAS technique better than cluster sampling technique in terms of resources to evaluate the immunization coverage in an urban area? To assess and compare the lot quality assurance sampling against cluster sampling in the evaluation of primary immunization coverage. Population-based cross-sectional study. Areas under Mathikere Urban Health Center. Children aged 12 months to 23 months. 220 in cluster sampling, 76 in lot quality assurance sampling. Percentages and Proportions, Chi square Test. (1) Using cluster sampling, the percentage of completely immunized, partially immunized and unimmunized children were 84.09%, 14.09% and 1.82%, respectively. With lot quality assurance sampling, it was 92.11%, 6.58% and 1.31%, respectively. (2) Immunization coverage levels as evaluated by cluster sampling technique were not statistically different from the coverage value as obtained by lot quality assurance sampling techniques. Considering the time and resources required, it was found that lot quality assurance sampling is a better technique in evaluating the primary immunization coverage in urban area.

  19. TRAN-STAT: statistics for environmental studies, Number 22. Comparison of soil-sampling techniques for plutonium at Rocky Flats

    International Nuclear Information System (INIS)

    Gilbert, R.O.; Bernhardt, D.E.; Hahn, P.B.

    1983-01-01

    A summary of a field soil sampling study conducted around the Rocky Flats Colorado plant in May 1977 is preseted. Several different soil sampling techniques that had been used in the area were applied at four different sites. One objective was to comparethe average 239 - 240 Pu concentration values obtained by the various soil sampling techniques used. There was also interest in determining whether there are differences in the reproducibility of the various techniques and how the techniques compared with the proposed EPA technique of sampling to 1 cm depth. Statistically significant differences in average concentrations between the techniques were found. The differences could be largely related to the differences in sampling depth-the primary physical variable between the techniques. The reproducibility of the techniques was evaluated by comparing coefficients of variation. Differences between coefficients of variation were not statistically significant. Average (median) coefficients ranged from 21 to 42 percent for the five sampling techniques. A laboratory study indicated that various sample treatment and particle sizing techniques could increase the concentration of plutonium in the less than 10 micrometer size fraction by up to a factor of about 4 compared to the 2 mm size fraction

  20. Référencement, e-marketing et visibilité web 30 pratiques pour décideurs et webmasters

    CERN Document Server

    Colantonio, Fred

    2013-01-01

    Le plus beau site web du monde est inutile s'il est introuvable !Les internautes sont pressés et exigeants; la concurrence nombreuse et organisée. Comment devenir meilleur et plus visible en exploitant des techniques simples ?A travers 30 pratiques, l'auteur répond à 2 préoccupations :- Comment vous trouver quand on vous cherche ?- Comment être visible là où on ne vousattend pas ?Construit principalement autour du référencement naturel et de la présence dans les moteurs de recherche, ce livre vous offre également un aperçu des techniques payantes d'e-marketing. En conclusion, l'exploitation p

  1. Stratified source-sampling techniques for Monte Carlo eigenvalue analysis

    International Nuclear Information System (INIS)

    Mohamed, A.

    1998-01-01

    In 1995, at a conference on criticality safety, a special session was devoted to the Monte Carlo ''Eigenvalue of the World'' problem. Argonne presented a paper, at that session, in which the anomalies originally observed in that problem were reproduced in a much simplified model-problem configuration, and removed by a version of stratified source-sampling. In this paper, stratified source-sampling techniques are generalized and applied to three different Eigenvalue of the World configurations which take into account real-world statistical noise sources not included in the model problem, but which differ in the amount of neutronic coupling among the constituents of each configuration. It is concluded that, in Monte Carlo eigenvalue analysis of loosely-coupled arrays, the use of stratified source-sampling reduces the probability of encountering an anomalous result over that if conventional source-sampling methods are used. However, this gain in reliability is substantially less than that observed in the model-problem results

  2. Ojo et al (2)

    African Journals Online (AJOL)

    DELL

    network geometry hence control how the samples' ... generate different permeability curves from wire- ... occupy in the reservoir pore system (McPhee et. ..... Fig.3. Poroperm cross-plot for a homogenous reservoir. Ojo et al.: Rock Type Based ...

  3. Evaluation of primary immunization coverage of infants under universal immunization programme in an urban area of Bangalore city using cluster sampling and lot quality assurance sampling techniques

    Directory of Open Access Journals (Sweden)

    Punith K

    2008-01-01

    Full Text Available Research Question: Is LQAS technique better than cluster sampling technique in terms of resources to evaluate the immunization coverage in an urban area? Objective: To assess and compare the lot quality assurance sampling against cluster sampling in the evaluation of primary immunization coverage. Study Design: Population-based cross-sectional study. Study Setting: Areas under Mathikere Urban Health Center. Study Subjects: Children aged 12 months to 23 months. Sample Size: 220 in cluster sampling, 76 in lot quality assurance sampling. Statistical Analysis: Percentages and Proportions, Chi square Test. Results: (1 Using cluster sampling, the percentage of completely immunized, partially immunized and unimmunized children were 84.09%, 14.09% and 1.82%, respectively. With lot quality assurance sampling, it was 92.11%, 6.58% and 1.31%, respectively. (2 Immunization coverage levels as evaluated by cluster sampling technique were not statistically different from the coverage value as obtained by lot quality assurance sampling techniques. Considering the time and resources required, it was found that lot quality assurance sampling is a better technique in evaluating the primary immunization coverage in urban area.

  4. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  5. Determination of some trace elements in biological samples using XRF and TXRF techniques

    International Nuclear Information System (INIS)

    Khuder, A.; Karjou, J.; Sawan, M. K.

    2006-07-01

    XRF and TXRF techniques were successfully used for the multi-element determination of trace elements in whole blood and human head hair samples. This was achieved by the direct analysis using XRF technique with different collimation units and by the optimized chemical procedures for TXRF analysis. Light element of S and P were preferably determined by XRF with primary x-ray excitation, while, elements of K, Ca, Fe, and Br were determined with a very good accuracy and precision using XRF with Cu- and Mo-secondary targets. The chemical procedure dependent on the preconcentration of trace elements by APDC was superiorly used for the determination of traces of Ni and Pb in the range of 1.0-1.7 μg/dl and 11-23 μg/dl, respectively, in whole blood samples by TXRF technique; determination of other elements as Cu and Zn was also achievable using this approach. Rb in whole blood samples was determined directly after the digestion of samples using PTFE-bomb for TXRF analysis. (author)

  6. Recent advances in sample preparation techniques and methods of sulfonamides detection - A review.

    Science.gov (United States)

    Dmitrienko, Stanislava G; Kochuk, Elena V; Apyari, Vladimir V; Tolmacheva, Veronika V; Zolotov, Yury A

    2014-11-19

    Sulfonamides (SAs) have been the most widely used antimicrobial drugs for more than 70 years, and their residues in foodstuffs and environmental samples pose serious health hazards. For this reason, sensitive and specific methods for the quantification of these compounds in numerous matrices have been developed. This review intends to provide an updated overview of the recent trends over the past five years in sample preparation techniques and methods for detecting SAs. Examples of the sample preparation techniques, including liquid-liquid and solid-phase extraction, dispersive liquid-liquid microextraction and QuEChERS, are given. Different methods of detecting the SAs present in food and feed and in environmental, pharmaceutical and biological samples are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Symbol synchronization and sampling frequency synchronization techniques in real-time DDO-OFDM systems

    Science.gov (United States)

    Chen, Ming; He, Jing; Cao, Zizheng; Tang, Jin; Chen, Lin; Wu, Xian

    2014-09-01

    In this paper, we propose and experimentally demonstrate a symbol synchronization and sampling frequency synchronization techniques in real-time direct-detection optical orthogonal frequency division multiplexing (DDO-OFDM) system, over 100-km standard single mode fiber (SSMF) using a cost-effective directly modulated distributed feedback (DFB) laser. The experiment results show that the proposed symbol synchronization based on training sequence (TS) has a low complexity and high accuracy even at a sampling frequency offset (SFO) of 5000-ppm. Meanwhile, the proposed pilot-assisted sampling frequency synchronization between digital-to-analog converter (DAC) and analog-to-digital converter (ADC) is capable of estimating SFOs with an accuracy of technique can also compensate SFO effects within a small residual SFO caused by deviation of SFO estimation and low-precision or unstable clock source. The two synchronization techniques are suitable for high-speed DDO-OFDM transmission systems.

  8. Assessing safety risk in electricity distribution processes using ET & BA improved technique and its ranking by VIKOR and TOPSIS models in fuzzy environment

    OpenAIRE

    S. Rahmani; M. Omidvari

    2016-01-01

    Introduction: Electrical industries are among high risk industries. The present study aimed to assess safety risk in electricity distribution processes using  ET&BA technique and also to compare with both VIKOR & TOPSIS methods in fuzzy environments.   Material and Methods: The present research is a descriptive study and ET&BA worksheet is the main data collection tool. Both Fuzzy TOPSIS and Fuzzy VIKOR methods were used for the worksheet analysis.   Result: Findi...

  9. ANALYSIS OF MONTE CARLO SIMULATION SAMPLING TECHNIQUES ON SMALL SIGNAL STABILITY OF WIND GENERATOR- CONNECTED POWER SYSTEM

    Directory of Open Access Journals (Sweden)

    TEMITOPE RAPHAEL AYODELE

    2016-04-01

    Full Text Available Monte Carlo simulation using Simple Random Sampling (SRS technique is popularly known for its ability to handle complex uncertainty problems. However, to produce a reasonable result, it requires huge sample size. This makes it to be computationally expensive, time consuming and unfit for online power system applications. In this article, the performance of Latin Hypercube Sampling (LHS technique is explored and compared with SRS in term of accuracy, robustness and speed for small signal stability application in a wind generator-connected power system. The analysis is performed using probabilistic techniques via eigenvalue analysis on two standard networks (Single Machine Infinite Bus and IEEE 16–machine 68 bus test system. The accuracy of the two sampling techniques is determined by comparing their different sample sizes with the IDEAL (conventional. The robustness is determined based on a significant variance reduction when the experiment is repeated 100 times with different sample sizes using the two sampling techniques in turn. Some of the results show that sample sizes generated from LHS for small signal stability application produces the same result as that of the IDEAL values starting from 100 sample size. This shows that about 100 sample size of random variable generated using LHS method is good enough to produce reasonable results for practical purpose in small signal stability application. It is also revealed that LHS has the least variance when the experiment is repeated 100 times compared to SRS techniques. This signifies the robustness of LHS over that of SRS techniques. 100 sample size of LHS produces the same result as that of the conventional method consisting of 50000 sample size. The reduced sample size required by LHS gives it computational speed advantage (about six times over the conventional method.

  10. Modified emission-transmission method for determining trace elements in solid samples using the XRF techniques

    International Nuclear Information System (INIS)

    Poblete, V.; Alvarez, M.; Hermosilla, M.

    2000-01-01

    This is a study of an analysis of trace elements in medium thick solid samples, by the modified transmission emission method, using the energy dispersion X-ray fluorescence technique (EDXRF). The effects of absorption and reinforcement are the main disadvantages of the EDXRF technique for the quantitative analysis of bigger elements and trace elements in solid samples. The implementation of this method and its application to a variety of samples was carried out using an infinitely thick multi-element white sample that calculates the correction factors by absorbing all the analytes in the sample. The discontinuities in the masic absorption coefficients versus energies association for each element, with medium thick and homogenous samples, are analyzed and corrected. A thorough analysis of the different theoretical and test variables are proven by using real samples, including certified material with known concentration. The simplicity of the calculation method and the results obtained show the method's major precision, with possibilities for the non-destructive routine analysis of different solid samples, using the EDXRF technique (author)

  11. Recent Trends in Microextraction Techniques Employed in Analytical and Bioanalytical Sample Preparation

    Directory of Open Access Journals (Sweden)

    Abuzar Kabir

    2017-12-01

    Full Text Available Sample preparation has been recognized as a major step in the chemical analysis workflow. As such, substantial efforts have been made in recent years to simplify the overall sample preparation process. Major focusses of these efforts have included miniaturization of the extraction device; minimizing/eliminating toxic and hazardous organic solvent consumption; eliminating sample pre-treatment and post-treatment steps; reducing the sample volume requirement; reducing extraction equilibrium time, maximizing extraction efficiency etc. All these improved attributes are congruent with the Green Analytical Chemistry (GAC principles. Classical sample preparation techniques such as solid phase extraction (SPE and liquid-liquid extraction (LLE are being rapidly replaced with emerging miniaturized and environmentally friendly techniques such as Solid Phase Micro Extraction (SPME, Stir bar Sorptive Extraction (SBSE, Micro Extraction by Packed Sorbent (MEPS, Fabric Phase Sorptive Extraction (FPSE, and Dispersive Liquid-Liquid Micro Extraction (DLLME. In addition to the development of many new generic extraction sorbents in recent years, a large number of molecularly imprinted polymers (MIPs created using different template molecules have also enriched the large cache of microextraction sorbents. Application of nanoparticles as high-performance extraction sorbents has undoubtedly elevated the extraction efficiency and method sensitivity of modern chromatographic analyses to a new level. Combining magnetic nanoparticles with many microextraction sorbents has opened up new possibilities to extract target analytes from sample matrices containing high volumes of matrix interferents. The aim of the current review is to critically audit the progress of microextraction techniques in recent years, which has indisputably transformed the analytical chemistry practices, from biological and therapeutic drug monitoring to the environmental field; from foods to phyto

  12. Development of core sampling technique for ITER Type B radwaste

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. G.; Hong, K. P.; Oh, W. H.; Park, M. C.; Jung, S. H.; Ahn, S. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Type B radwaste (intermediate level and long lived radioactive waste) imported from ITER vacuum vessel are to be treated and stored in basement of hot cell building. The Type B radwaste treatment process is composed of buffer storage, cutting, sampling/tritium measurement, tritium removal, characterization, pre-packaging, inspection/decontamination, and storage etc. The cut slices of Type B radwaste components generated from cutting process undergo sampling process before and after tritium removal process. The purpose of sampling is to obtain small pieces of samples in order to investigate the tritium content and concentration of Type B radwaste. Core sampling, which is the candidates of sampling technique to be applied to ITER hot cell, is available for not thick (less than 50 mm) metal without use of coolant. Experimented materials were SS316L and CuCrZr in order to simulate ITER Type B radwaste. In core sampling, substantial secondary wastes from cutting chips will be produced unavoidably. Thus, core sampling machine will have to be equipped with disposal system such as suction equipment. Core sampling is considered an unfavorable method for tool wear compared to conventional drilling.

  13. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    Science.gov (United States)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  14. Analysis of pure and malachite green doped polysulfone sample using FT-IR technique

    Science.gov (United States)

    Nayak, Rashmi J.; Khare, P. K.; Nayak, J. G.

    2018-05-01

    The sample of pure and malachite green doped Polysulfone in the form of foil was prepared by isothermal immersion technique. For the preparation of pure sample 4 gm of Polysulfone was dissolved in 50 ml of Dimethyl farmamide (DMF) solvent, while for the preparation of doped sample 10 mg, 50 mg and 100 mg Malachite Green was mixed with 4 gm of Polysulfone respectively. For the study of structural characterization of these pure and doped sample, Fourier Transform Infra-Red Spectroscopy (FT-IR) technique was used. This study shows that the intensity of transmittance decreases as the ratio of doping increases in pure polysulfone. The reduction in intensity of transmittance is clearly apparent in the present case more over the bands were broader which indicates towards charge transfer interaction between the donar and acceptor molecule.

  15. Elaboration, microstructure, propriétés électriques et magnétiques de matériaux textures dans les systèmes Nd-Ce-Cu-O et Bi-Sr-Ca-Cu-O

    Science.gov (United States)

    Dhalenne, G.; Trouilleux, L.; Jegoudez, J.; Revcolevschi, A.; Monod, P.; Kormann, R.; Ganne, J. P.; Motohira, N.; Kitazawa, K.

    1991-11-01

    Superconducting textured materials were grown from the melt by a floating zone technique in the Nd-Ce-Cu-O and Bi-Sr-Ca-Cu-O systems. The influence of growth conditions and starting compositions on the microstructures and phase composition of the samples were studied by optical microscopy under polarized light, electron microprobe analysis and X-ray diffraction. The superconducting properties of these samples were examined by both electrical resistivity and magnetic measurements. A very strong influence of the microstructure on the superconducting properties as well as a magnetic and electrical anisotropy were shown. In the case of the Bi-Sr-Ca-Cu-O system, critical current densities ranging from 1 600 to 3 000 A.cm^{-2} were measured at 77 K. Des matériaux supraconducteurs texturés ont été élaborés à partir de l'état liquide dans les systèmes Nd-Ce-Cu-O et Bi-Sr-Ca-Cu-O par une technique de fusion de zone. L'influence des conditions de croissance et des compositions initiales sur la microstructure des échantillons a été étudiée par microscopie optique en lumière polarisée, microsonde électronique et diffraction des rayons X. Les propriétés supraconductrices des échantillons ont été examinées par des mesures électriques et magnétiques. Il a été observé une forte influence de la microstructure sur les propriétés supraconductrices ainsi qu'une anisotropie électrique et magnétique. Dans le cas du système Bi-Sr-Ca-Cu-O, les densités de courant critique mesurées à 77 K sont comprises entre 1 600 et 3 000 A.cm^{-2}.

  16. Monsieur Omar Fassi Fihri Secrétaire perpétuel Académie HASSAN II des Sciences et Techniques Royaume du Maroc

    CERN Document Server

    Maximilien Brice

    2010-01-01

    CERN-HI-1007135 01: M. Gouighri, Boursier de l’Académie des Sciences, Université Hassan II; J. Collot, Directeur du Laboratoire international associé; R. Heuer,\tDirecteur général du CERN;O. Fassi Fehri, Secrétaire perpétuel, Académie Hassan II des Sciences et Techniques, Maroc; S. Boutouil, Boursière du Laboratoire international associé; R. Klapisch, Fondation Partager le Savoir, Président et fondateur; G.Carnot, Président de la Fondation Carnot.

  17. Réservations et discrimination positive en Inde. Données juridiques et techniques Reservations and Affirmative Action in India. Legal and Technical Data

    Directory of Open Access Journals (Sweden)

    Jean-Claude Bonnan

    2009-03-01

    Full Text Available Les dispositions qui sont résumées ici, et dont on donne quelques éléments constitutionnels en annexe, ne sont pas seulement théoriques et de pure forme, elles sont mises en application et font l’objet d’une pratique précise et suivie. Le système des quotas ne se limite pas en effet à des prescriptions législatives et réglementaires à destination des assemblées élues et des services administratifs, il est accompagné de tout un dispositif administratif et financier propre à assurer son effecti...

  18. Thermoluminescence du quartz naturel et artificiel pur ou dopé des ions Fe++ et Fe+++: application à la datation des poteries

    Directory of Open Access Journals (Sweden)

    1978-01-01

    Full Text Available La thermoluminescence constatée sur les échantillons de poteries et conduisant à la datation archéologique de celles-ci, est due aux inclusions de quartz initialement contenues dans l'argile. Nous présentons une étude de la thermoluminescence d'échantillons de quartz monocristallin synthétique dans lesquels des impuretés ont été volontairement ajoutées et appliquons les résultats à une nouvelle technique de datation, la méthode DATE (différence d'atténuation temporelle des émissions. La termoluminiscencia constatada en muestras de cerámica permite una datación arqueológica es debida a las inclusiones de cuarzo inicialmente contenidas en la arcilla. Se presenta un estudio de la termoluminiscencia de muestras de cuarzo monocristalino sintético en las cuales han sido colocadas voluntariamente impurezas se han aplicado los resultados de una nueva técnica de fechado, el método DATE (Diferencia de atenuación temporal de emisiones. The thermoluminescence observed on samples of pottery and leading to their archaeological dating is a result of the presence of quartz particles originally enclosed in the clay. We offer a study of the termoluminescence of samples of synthetic mono-crystalline quartz doped in with impurities and apply the results to a new dating technique, the 'DATE' method, based upon difference in time attenuation of the emissions.

  19. Separation Techniques for Quantification of Radionuclides in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Dusan Galanda

    2009-01-01

    Full Text Available The reliable and quantitative measurement of radionuclides is important in order to determine environmental quality and radiation safety, and to monitor regulatory compliance. We examined soil samples from Podunajske Biskupice, near the city of Bratislava in the Slovak Republic, for the presence of several natural (238U, 232Th, 40K and anthropogenic (137Cs, 90Sr, 239Pu, 240Pu, 241Am radionuclides. The area is adjacent to a refinery and hazardous waste processing center, as well as the municipal incinerator plant, and so might possess an unusually high level of ecotoxic metals. We found that the levels of both naturally occurring and anthropogenic radionuclides fell within the expected ranges, indicating that these facilities pose no radiological threat to the local environment. During the course of our analysis, we modified existing techniques in order to allow us to handle the unusually large and complex samples that were needed to determine the levels of 239Pu, 240Pu, and 241Am activity. We also rated three commercial techniques for the separation of 90Sr from aqueous solutions and found that two of them, AnaLig Sr-01 and Empore Extraction Disks, were suitable for the quantitative and reliable separation of 90Sr, while the third, Sr-Spec Resin, was less so. The main criterion in evaluating these methods was the chemical recovery of 90Sr, which was less than we had expected. We also considered speed of separation and additional steps needed to prepare the sample for separation.

  20. Accelerated Solvent Extraction: An Innovative Sample Extraction Technique for Natural Products

    International Nuclear Information System (INIS)

    Hazlina Ahmad Hassali; Azfar Hanif Abd Aziz; Rosniza Razali

    2015-01-01

    Accelerated solvent extraction (ASE) is one of the novel techniques that have been developed for the extraction of phytochemicals from plants in order to shorten the extraction time, decrease the solvent consumption, increase the extraction yield and enhance the quality of extracts. This technique combines elevated temperatures and pressure with liquid solvents. This paper gives a brief overview of accelerated solvent extraction technique for sample preparation and its application to the extraction of natural products. Through practical examples, the effects of operational parameters such as temperature, volume of solvent used, extraction time and extraction yields on the performance of ASE are discussed. It is demonstrated that ASE technique allows reduced solvent consumption and shorter extraction time, while the extraction yields are even higher than those obtained with conventional methods. (author)

  1. Science et technologie du collage

    CERN Document Server

    Cognard, Jacques

    2003-01-01

    L'Homme a su coller avant de savoir écrire et compter. Le collage est en effet l'une des premières techniques d'assemblage d'une structure que l'homme ait utilisée, technique qui n'est devenue science qu'au début du 20e siècle avec la fabrication des premières colles synthétiques. Cette science de l'adhésion a considérablement progressé ces dix dernières années et ce livre présente l'état actuel des connaissances en décrivant les progrès considérables réalisés dans la compréhension des phénomènes fondamentaux qui font qu'un collage tient bien et durablement. Après l'exposé des bases scientifiques nécessaires et des modèles théoriques récents, l'auteur introduit la distinction entre collages faibles et collages forts puis expose les difficultés rencontrées dans les cas pratiques, difficultés souvent dues à la complexité de la chimie des surfaces et des réactions surface-polymère. L'ouvrage se termine par la présentation de quelques applications récentes, en particulier dans...

  2. Practical aspects of the resin bead technique for mass spectrometric sample loading

    International Nuclear Information System (INIS)

    Walker, R.L.; Pritchard, C.A.; Carter, J.A.; Smith, D.H.

    1976-07-01

    Using an anion resin bead as a loading vehicle for uranium and plutonium samples which are to be analyzed isotopically in a mass spectrometer has many advantages over conventional techniques. It is applicable to any laboratory routinely performing such analyses, but should be particularly relevant for Safeguards' purposes. Because the techniques required differ markedly from those of conventional methods, this report has been written to describe them in detail to enable those unfamiliar with the technique to master it with a minimum of trouble

  3. A fully blanketed early B star LTE model atmosphere using an opacity sampling technique

    International Nuclear Information System (INIS)

    Phillips, A.P.; Wright, S.L.

    1980-01-01

    A fully blanketed LTE model of a stellar atmosphere with Tsub(e) = 21914 K (thetasub(e) = 0.23), log g = 4 is presented. The model includes an explicit representation of the opacity due to the strongest lines, and uses a statistical opacity sampling technique to represent the weaker line opacity. The sampling technique is subjected to several tests and the model is compared with an atmosphere calculated using the line-distribution function method. The limitations of the distribution function method and the particular opacity sampling method used here are discussed in the light of the results obtained. (author)

  4. Using Malaise traps to sample ground beetles (Coleoptera: Carabidae)

    Science.gov (United States)

    Michael D. Ulyshen; James L. Hanula; Scott Horn

    2005-01-01

    Pitfall traps provide an easy and inexpensive way to sample ground-dwelling arthropods (Spence and Niemela 1994; Spence et al. 1997; Abildsnes and Tommeras 2000) and have been used exclusively in many studies of the abundance and diversity of ground beetles (Coleoptera: Carabidae). Despite the popularity of this trapping technique, pitfall traps have many disadvantages...

  5. Sample preparation techniques based on combustion reactions in closed vessels - A brief overview and recent applications

    International Nuclear Information System (INIS)

    Flores, Erico M.M.; Barin, Juliano S.; Mesko, Marcia F.; Knapp, Guenter

    2007-01-01

    In this review, a general discussion of sample preparation techniques based on combustion reactions in closed vessels is presented. Applications for several kinds of samples are described, taking into account the literature data reported in the last 25 years. The operational conditions as well as the main characteristics and drawbacks are discussed for bomb combustion, oxygen flask and microwave-induced combustion (MIC) techniques. Recent applications of MIC techniques are discussed with special concern for samples not well digested by conventional microwave-assisted wet digestion as, for example, coal and also for subsequent determination of halogens

  6. The application of statistical and/or non-statistical sampling techniques by internal audit functions in the South African banking industry

    Directory of Open Access Journals (Sweden)

    D.P. van der Nest

    2015-03-01

    Full Text Available This article explores the use by internal audit functions of audit sampling techniques in order to test the effectiveness of controls in the banking sector. The article focuses specifically on the use of statistical and/or non-statistical sampling techniques by internal auditors. The focus of the research for this article was internal audit functions in the banking sector of South Africa. The results discussed in the article indicate that audit sampling is still used frequently as an audit evidence-gathering technique. Non-statistical sampling techniques are used more frequently than statistical sampling techniques for the evaluation of the sample. In addition, both techniques are regarded as important for the determination of the sample size and the selection of the sample items

  7. Rapport final de la Collaboration CERN-CNRS pour la construction du LHC Accord Technique d'Exécution No 2 Cryostats et assemblage des sections droites courtes (SSS) du LHC

    CERN Document Server

    Bergot, JB; Poncet, A; Rohmig, P; Roy, E; Vincent, D

    2006-01-01

    Depuis 1995 et suite à la signature du protocole de Collaboration, le CERN, le CEA et le CNRS ont étroitement collaboré dans le cadre de la contribution exceptionnelle de la France à la construction du LHC. Pour le CNRS, l'Institut de Physique Nucléaire d'Orsay a pris en charge deux Accords Techniques d'Exécution. Le premier concerne la conception et l'assemblage des Sections Droites Courtes de la machine, et le deuxième, l'étalonnage des thermomètres cryogéniques du LHC. Dans le cadre de l'Accord Technique d'Exécution N°2, le Bureau d'Etudes de la Division Accélérateur de l'IPNO et le groupe AT-CRI du CERN ont travaillé de concert pour mener à bien la conception des SSS (Short Straight Section) et de tous les équipements nécessaires à l'assemblage. Ce rapport a donc pour objectif de dresser, en termes d'historique, d'organisation, de résultats quantitatifs et qualitatifs et de moyens mis en ?uvre, un tableau aussi complet que possible du déroulement de cette Collaboration entre le CERN e...

  8. X-ray spectrometry and X-ray microtomography techniques for soil and geological samples analysis

    International Nuclear Information System (INIS)

    Kubala-Kukuś, A.; Banaś, D.; Braziewicz, J.; Dziadowicz, M.; Kopeć, E.; Majewska, U.; Mazurek, M.; Pajek, M.; Sobisz, M.; Stabrawa, I.; Wudarczyk-Moćko, J.; Góźdź, S.

    2015-01-01

    A particular subject of X-ray fluorescence analysis is its application in studies of the multielemental sample of composition in a wide range of concentrations, samples with different matrices, also inhomogeneous ones and those characterized with different grain size. Typical examples of these kinds of samples are soil or geological samples for which XRF elemental analysis may be difficult due to XRF disturbing effects. In this paper the WDXRF technique was applied in elemental analysis concerning different soil and geological samples (therapeutic mud, floral soil, brown soil, sandy soil, calcium aluminum cement). The sample morphology was analyzed using X-ray microtomography technique. The paper discusses the differences between the composition of samples, the influence of procedures with respect to the preparation of samples as regards their morphology and, finally, a quantitative analysis. The results of the studies were statistically tested (one-way ANOVA and correlation coefficients). For lead concentration determination in samples of sandy soil and cement-like matrix, the WDXRF spectrometer calibration was performed. The elemental analysis of the samples was complemented with knowledge of chemical composition obtained by X-ray powder diffraction.

  9. X-ray spectrometry and X-ray microtomography techniques for soil and geological samples analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kubala-Kukuś, A.; Banaś, D.; Braziewicz, J. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Dziadowicz, M.; Kopeć, E. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Majewska, U. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Mazurek, M.; Pajek, M.; Sobisz, M.; Stabrawa, I. [Institute of Physics, Jan Kochanowski University, ul. Świetokrzyska 15, 25-406 Kielce (Poland); Wudarczyk-Moćko, J. [Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Góźdź, S. [Holycross Cancer Center, ul. Artwińskiego 3, 25-734 Kielce (Poland); Institute of Public Health, Jan Kochanowski University, IX Wieków Kielc 19, 25-317 Kielce (Poland)

    2015-12-01

    A particular subject of X-ray fluorescence analysis is its application in studies of the multielemental sample of composition in a wide range of concentrations, samples with different matrices, also inhomogeneous ones and those characterized with different grain size. Typical examples of these kinds of samples are soil or geological samples for which XRF elemental analysis may be difficult due to XRF disturbing effects. In this paper the WDXRF technique was applied in elemental analysis concerning different soil and geological samples (therapeutic mud, floral soil, brown soil, sandy soil, calcium aluminum cement). The sample morphology was analyzed using X-ray microtomography technique. The paper discusses the differences between the composition of samples, the influence of procedures with respect to the preparation of samples as regards their morphology and, finally, a quantitative analysis. The results of the studies were statistically tested (one-way ANOVA and correlation coefficients). For lead concentration determination in samples of sandy soil and cement-like matrix, the WDXRF spectrometer calibration was performed. The elemental analysis of the samples was complemented with knowledge of chemical composition obtained by X-ray powder diffraction.

  10. Sampling methods for rumen microbial counts by Real-Time PCR techniques

    Directory of Open Access Journals (Sweden)

    S. Puppo

    2010-02-01

    Full Text Available Fresh rumen samples were withdrawn from 4 cannulated buffalo females fed a fibrous diets in order to quantify bacteria concentration in the rumen by Real-Time PCR techniques. To obtain DNA of a good quality from whole rumen fluid, eight (M1-M8 different pre-filtration methods (cheese cloths, glass-fibre and nylon filter in combination with various centrifugation speeds (1000, 5000 and 14,000 rpm were tested. Genomic DNA extraction was performed either on fresh or frozen samples (-20°C. The quantitative bacteria analysis was realized according to Real-Time PCR procedure for Butyrivibrio fibrisolvens reported in literature. M5 resulted the best sampling procedure allowing to obtain a suitable genomic DNA. No differences were revealed between fresh and frozen samples.

  11. Random sampling technique for ultra-fast computations of molecular opacities for exoplanet atmospheres

    Science.gov (United States)

    Min, M.

    2017-10-01

    Context. Opacities of molecules in exoplanet atmospheres rely on increasingly detailed line-lists for these molecules. The line lists available today contain for many species up to several billions of lines. Computation of the spectral line profile created by pressure and temperature broadening, the Voigt profile, of all of these lines is becoming a computational challenge. Aims: We aim to create a method to compute the Voigt profile in a way that automatically focusses the computation time into the strongest lines, while still maintaining the continuum contribution of the high number of weaker lines. Methods: Here, we outline a statistical line sampling technique that samples the Voigt profile quickly and with high accuracy. The number of samples is adjusted to the strength of the line and the local spectral line density. This automatically provides high accuracy line shapes for strong lines or lines that are spectrally isolated. The line sampling technique automatically preserves the integrated line opacity for all lines, thereby also providing the continuum opacity created by the large number of weak lines at very low computational cost. Results: The line sampling technique is tested for accuracy when computing line spectra and correlated-k tables. Extremely fast computations ( 3.5 × 105 lines per second per core on a standard current day desktop computer) with high accuracy (≤1% almost everywhere) are obtained. A detailed recipe on how to perform the computations is given.

  12. Sample preparation techniques in trace element analysis by X-ray emission spectroscopy

    International Nuclear Information System (INIS)

    Valkovic, V.

    1983-11-01

    The report, written under a research contract with the IAEA, contains a detailed presentation of the most difficult problem encountered in the trace element analysis by methods of the X-ray emission spectroscopy, namely the sample preparation techniques. The following items are covered. Sampling - with specific consideration of aerosols, water, soil, biological materials, petroleum and its products, storage of samples and their handling. Pretreatment of samples - preconcentration, ashing, solvent extraction, ion exchange and electrodeposition. Sample preparations for PIXE - analysis - backings, target uniformity and homogeneity, effects of irradiation, internal standards and specific examples of preparation (aqueous, biological, blood serum and solid samples). Sample preparations for radioactive sources or tube excitation - with specific examples (water, liquid and solid samples, soil, geological, plants and tissue samples). Finally, the problem of standards and reference materials, as well as that of interlaboratory comparisons, is discussed

  13. Techniques de hacking

    CERN Document Server

    Erickson, Jon

    2008-01-01

    Dans cet ouvrage, Jon Erickson présente les bases de la programmation en C du point de vue du hacker et dissèque plusieurs techniques de hacking, passées et actuelles, afin de comprendre comment et pourquoi elles fonctionnent. Même si vous ne savez pas programmer, ce livre vous donnera une vue complète de la programmation, de l'architecture des machines, des communications réseau et des techniques de hacking existantes. Associez ces connaissances à l'environnement Linux fourni et laissez libre cours à votre imagination. Avec ce livre vous apprendrez à : • programmer les ordinateurs en C, en assembleur et avec des scripts shell ; • inspecter les registres du processeur et la mémoire système avec un débogueur afin de comprendre précisément ce qui se passe ; Vous découvrirez comment les hackers parviennent à : • corrompre la mémoire d'un système, en utilisant les débordements de tampons et les chaînes de format, pour exécuter un code quelconque ; • surpasser les mesures de sécurit...

  14. Évolutions réglementaire et normative de l’assainissement non collectif : comment modifient-elles en profondeur le paysage technique ?

    Directory of Open Access Journals (Sweden)

    BOUTIN, Catherine

    2012-12-01

    Full Text Available En France, la réglementation relative aux prescriptions techniques applicables aux installations d’assainissement non collectif ne cesse d’évolueret conduit à l’apparition sur le territoire de nombreux produits comme les «micro-stations». Cette note réalise un focus des principales évolutions et fournit un tableau de classification de ces filières.

  15. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis

    Science.gov (United States)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-01

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH4+ strategy for ethylene and SO2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO2 from fruits. It was satisfied that trace ethylene and SO2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO2 during the entire LVCC sampling process were proved to be samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS.

  16. Technique du Micro-Enseignement: Une Approche Pour Enseigner La Pratique de La Lecture aux Apprenants de Niveau A2 et La Perception de Cette Technique Par Les Futurs Enseignants

    Directory of Open Access Journals (Sweden)

    Nurten ÖZÇELİK

    2017-09-01

    Full Text Available Cette étude a été préparée en vue de déterminer les difficultés rencontrées par les futurs enseignants lors de l’enseignement de la lecture aux apprenants de niveau A2 par la technique du micro-enseignement, et de mettre à jour leurs opinions concernant les avantages ainsi que les inconvénients de cette technique. Le groupe de travail est composé de 20 futurs enseignants (14 femmes, 6 hommes du Département de la Didactique du FLE de la Faculté Pédagogique de l’Université Gazi, pour le deuxième semestre de la période 2014-2015. Les données recueillies par les questions à réponses ouvertes ont été évaluées par la méthode de l’analyse descriptive, à la suite des calculs de fréquence. Selon les résultats obtenus, les futurs enseignants ont surtout du mal à prononcer le français, à gérer leurs émotions, à préparer une présentation, des activités de pré-lecture et du dossier de présentation. Augmenter la confiance en soi, apprendre à préparer un plan de cours, donner la possibilité de voir les aspects insuffisants sont les points positifs de la technique. L’insuffisance des participations au cours, l’artificialité du milieu de la classe, la subjectivité des critiques des pairs sont indiqués par les participants comme les inconvénients de cette technique.

  17. Experimental technique to measure thoron generation rate of building material samples using RAD7 detector

    International Nuclear Information System (INIS)

    Csige, I.; Szabó, Zs.; Szabó, Cs.

    2013-01-01

    Thoron ( 220 Rn) is the second most abundant radon isotope in our living environment. In some dwellings it is present in significant amount which calls for its identification and remediation. Indoor thoron originates mainly from building materials. In this work we have developed and tested an experimental technique to measure thoron generation rate in building material samples using RAD7 radon-thoron detector. The mathematical model of the measurement technique provides the thoron concentration response of RAD7 as a function of the sample thickness. For experimental validation of the technique an adobe building material sample was selected for measuring the thoron concentration at nineteen different sample thicknesses. Fitting the parameters of the model to the measurement results, both the generation rate and the diffusion length of thoron was estimated. We have also determined the optimal sample thickness for estimating the thoron generation rate from a single measurement. -- Highlights: • RAD7 is used for the determination of thoron generation rate (emanation). • The described model takes into account the thoron decay and attenuation. • The model describes well the experimental results. • A single point measurement method is offered at a determined sample thickness

  18. Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments

    Science.gov (United States)

    2015-08-01

    biodegradation . As discussed in Fernandez et al. (2009b), target compounds like PCBs and PAHs diffuse through the surrounding environmental media... biodegradation . The PE passive sampling technique may also offer significant cost savings per site for sample collection and analysis cost. When compared with...water, detergent), Nitrile gloves, aluminum foil, plastic sheeting, rope, paper towels, garbage bags , bubble wrap, Ziplock bags , and ice. • Non

  19. Sampling phased array - a new technique for ultrasonic signal processing and imaging

    OpenAIRE

    Verkooijen, J.; Boulavinov, A.

    2008-01-01

    Over the past 10 years, the improvement in the field of microelectronics and computer engineering has led to significant advances in ultrasonic signal processing and image construction techniques that are currently being applied to non-destructive material evaluation. A new phased array technique, called 'Sampling Phased Array', has been developed in the Fraunhofer Institute for Non-Destructive Testing([1]). It realises a unique approach of measurement and processing of ultrasonic signals. Th...

  20. The study of hard microporous material using the ultrafine section technique (1961); Etude des materiaux microporeux durs par la technique des coupes ultraminces (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Magdalena, Th [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The conventional replica techniques for the examination of surfaces or fractures with the electron microscope are unsuitable for refractories or microporous bodies. The method of cutting ultrafine sections with a diamond cutter, the sample being impregnated with methyl methacrylate, has the advantage of making possible the direct examination by transmission of the sample. (author) [French] Les techniques classiques de repliques pour l'examen de surfaces ou de fractures au microscope electronique sont difficilement applicables aux refractaires et aux microporeux. Les coupes ultraminces au couteau de diamant d'echantillons enrobes dans le methyl-methacrylate ont l'avantage de permettre l'examen direct par transmission des corps etudies. (auteur)

  1. Two-compartment, two-sample technique for accurate estimation of effective renal plasma flow: Theoretical development and comparison with other methods

    International Nuclear Information System (INIS)

    Lear, J.L.; Feyerabend, A.; Gregory, C.

    1989-01-01

    Discordance between effective renal plasma flow (ERPF) measurements from radionuclide techniques that use single versus multiple plasma samples was investigated. In particular, the authors determined whether effects of variations in distribution volume (Vd) of iodine-131 iodohippurate on measurement of ERPF could be ignored, an assumption implicit in the single-sample technique. The influence of Vd on ERPF was found to be significant, a factor indicating an important and previously unappreciated source of error in the single-sample technique. Therefore, a new two-compartment, two-plasma-sample technique was developed on the basis of the observations that while variations in Vd occur from patient to patient, the relationship between intravascular and extravascular components of Vd and the rate of iodohippurate exchange between the components are stable throughout a wide range of physiologic and pathologic conditions. The new technique was applied in a series of 30 studies in 19 patients. Results were compared with those achieved with the reference, single-sample, and slope-intercept techniques. The new two-compartment, two-sample technique yielded estimates of ERPF that more closely agreed with the reference multiple-sample method than either the single-sample or slope-intercept techniques

  2. Neutron activation analysis technique and X-ray fluorescence in bovine liver sample

    International Nuclear Information System (INIS)

    Maihara, V.A.; Favaro, D.I.T.; Vasconcellos, M.B.A.; Sato, I.M.; Salvador, V.L.

    2002-01-01

    Many analytical techniques have been used in food and diet analysis in order to determine a great number of nutritional elements, ranging from percentage to ng g -1 , with high sensitivity and accuracy. Instrumental Neutron activation Analysis (INAA) has been employed to certificate many trace elements in biological reference materials. More recently, the X-Ray Fluorescence (FRX-WD) has been also used to determine some essential elements in food samples. The INAA has been applied in nutrition studies in our laboratory at IPEN since the 80 s. For the development of analytical methodologies the use of the reference materials with the same characteristics of the sample analyzed is essential. Several Brazilian laboratories do not have conditions to use these materials due their high cost.In this paper preliminary results of commercial bovine liver sample analyses obtained by INAA and WD-XRF methods are presented. This sample was prepared to be a Brazilian candidate of reference material for a group of laboratories participating in a research project sponsored by FAPESP. The concentrations of some elements like Cl, K, Na, P, S and trace elements Br, Ca, Co, Cu, Fe, Mg, Mn, Mo, Rb, Se and Zn were determined by INAA and WD-XFR. For validation methodology of both techniques, NIST SRM 1577b Bovine Liver reference material was analyzed and the detection limits were calculated. The concentrations of elements determined by both analytical techniques were compared by using the Student's t-test and for Cl, Cu, Fe, K, Mg, Na, Rn and Zn the results do show no statistical difference for 95% significance level. (author)

  3. Improved mesh based photon sampling techniques for neutron activation analysis

    International Nuclear Information System (INIS)

    Relson, E.; Wilson, P. P. H.; Biondo, E. D.

    2013-01-01

    The design of fusion power systems requires analysis of neutron activation of large, complex volumes, and the resulting particles emitted from these volumes. Structured mesh-based discretization of these problems allows for improved modeling in these activation analysis problems. Finer discretization of these problems results in large computational costs, which drives the investigation of more efficient methods. Within an ad hoc subroutine of the Monte Carlo transport code MCNP, we implement sampling of voxels and photon energies for volumetric sources using the alias method. The alias method enables efficient sampling of a discrete probability distribution, and operates in 0(1) time, whereas the simpler direct discrete method requires 0(log(n)) time. By using the alias method, voxel sampling becomes a viable alternative to sampling space with the 0(1) approach of uniformly sampling the problem volume. Additionally, with voxel sampling it is straightforward to introduce biasing of volumetric sources, and we implement this biasing of voxels as an additional variance reduction technique that can be applied. We verify our implementation and compare the alias method, with and without biasing, to direct discrete sampling of voxels, and to uniform sampling. We study the behavior of source biasing in a second set of tests and find trends between improvements and source shape, material, and material density. Overall, however, the magnitude of improvements from source biasing appears to be limited. Future work will benefit from the implementation of efficient voxel sampling - particularly with conformal unstructured meshes where the uniform sampling approach cannot be applied. (authors)

  4. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis.

    Science.gov (United States)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-05

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH 4 + strategy for ethylene and SO 2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO 2 from fruits. It was satisfied that trace ethylene and SO 2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO 2 during the entire LVCC sampling process were proved to be gas targets from real samples by SERS. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. The influence of serial fecal sampling on the diagnosis of giardiasis in humans, dogs, and cats.

    Science.gov (United States)

    Uchôa, Flávia Fernandes de Mendonça; Sudré, Adriana Pittella; Macieira, Daniel de Barros; Almosny, Nádia Regina Pereira

    2017-08-24

    Giardia infection is a common clinical problem in humans and pets. The diagnosis of giardiasis is challenging as hosts intermittently excrete protozoan cysts in their feces. In the present study, we comparatively evaluated two methods of serial fecal sampling in humans, dogs, and cats from Rio de Janeiro, Brazil. The Faust et al. technique was used to examine fecal specimens collected in triplicate from 133 patients (52 humans, 60 dogs, and 21 cats). Specimens from 74 patients were received from the group assigned to carry out sampling on consecutive days - 34 humans, 35 dogs, and 5 cats, and specimens from 59 patients were received from the group assigned to carry out sampling on non-consecutive, separate days - 18 human beings, 25 dogs, and 16 cats. G. duodenalis cysts were found in stools of 30 individuals. Multiple stool sampling resulted in an increase in the number of samples that were positive for Giardia in both groups. The authors therefore conclude that multiple stool sampling increases the sensitivity of the Faust et al . technique to detect G. duodenalis cysts in samples from humans, cats and dogs.

  6. Diagnostic prénatal: quelles sont les techniques actuelles et futures ? (flyer)

    CERN Multimedia

    2002-01-01

    La majorité des bébés qui viennent au monde ne présentent pas d'anomalies particulières. Cependant, il faut savoir qu'environ 1 foetus 170 présente une anomalie chromosomique (défaut de la structure ou du nombre de chromosomes) qui va peser plus ou moins lourdement sur sa vie future et 1 foetus sur 100 présente une maladie génique due à un changement dans un gène. Le diagnostic prénatal a connu et connaît une formidable expansion grâce aux progrès technologiques en génétique et imagerie foetale.

  7. Application of digital sampling techniques to particle identification in scintillation detectors

    International Nuclear Information System (INIS)

    Bardelli, L.; Bini, M.; Poggi, G.; Taccetti, N.

    2002-01-01

    In this paper, the use of a fast digitizing system for identification of fast charged particles with scintillation detectors is discussed. The three-layer phoswich detectors developed in the framework of the FIASCO experiment for the detection of light charged particles (LCP) and intermediate mass fragments (IMF) emitted in heavy-ion collisions at Fermi energies are briefly discussed. The standard analog electronics treatment of the signals for particle identification is illustrated. After a description of the digitizer designed to perform a fast digital sampling of the phoswich signals, the feasibility of particle identification on the sampled data is demonstrated. The results obtained with two different pulse shape discrimination analyses based on the digitally sampled data are compared with the standard analog signal treatment. The obtained results suggest, for the present application, the replacement of the analog methods with the digital sampling technique

  8. Uranium content measurement in drinking water samples using track etch technique

    International Nuclear Information System (INIS)

    Kumar, Mukesh; Kumar, Ajay; Singh, Surinder; Mahajan, R.K.; Walia, T.P.S.

    2003-01-01

    The concentration of uranium has been assessed in drinking water samples collected from different locations in Bathinda district, Punjab, India. The water samples are taken from hand pumps and tube wells. Uranium is determined using fission track technique. Uranium concentration in the water samples varies from 1.65±0.06 to 74.98±0.38 μg/l. These values are compared with safe limit values recommended for drinking water. Most of the water samples are found to have uranium concentration above the safe limit. Analysis of some heavy metals (Zn, Cd, Pb and Cu) in water is also done in order to see if some correlation exists between the concentration of uranium and these heavy metals. A weak positive correlation has been observed between the concentration of uranium and heavy metals of Pb, Cd and Cu

  9. Attempts to develop a new nuclear measurement technique of β-glucuronidase levels in biological samples

    International Nuclear Information System (INIS)

    Unak, T.; Avcibasi, U.; Yildirim, Y.; Cetinkaya, B.

    2003-01-01

    β-Glucuronidase is one of the most important hydrolytic enzymes in living systems and plays an essential role in the detoxification pathway of toxic materials incorporated into the metabolism. Some organs, especially liver and some tumour tissues, have high level of β-glucuronidase activity. As a result the enzymatic activity of some kind of tumour cells, the radiolabelled glucuronide conjugates of cytotoxic, as well as radiotoxic compounds have potentially very valuable diagnostic and therapeutic applications in cancer research. For this reason, a sensitive measurement of β-glucuronidase levels in normal and tumour tissues is a very important step for these kinds of applications. According to the classical measurement method of β-glucuronidase activity, in general, the quantity of phenolphthalein liberated from its glucuronide conjugate, i.e. phenolphthalein-glucuronide, by β-glucuronidase has been measured by use of the spectrophotometric technique. The lower detection limit of phenolphthalein by the spectrophotometric technique is about 1-3 mg. This means that the β-glucuronidase levels could not be detected in biological samples having lower levels of β-glucuronidase activity and therefore the applications of the spectrophotometric technique in cancer research are very seriously limited. Starting from this consideration, we recently attempted to develop a new nuclear technique to measure much lower concentrations of β-glucuronidase in biological samples. To improve the detection limit, phenolphthalein-glucuronide and also phenyl-N-glucuronide were radioiodinated with 131 I and their radioactivity was measured by use of the counting technique. Therefore, the quantity of phenolphthalein or aniline radioiodinated with 131 I and liberated by the deglucuronidation reactivity of β-glucuronidase was used in an attempt to measure levels lower than the spectrophotometric measurement technique. The results obtained clearly verified that 0.01 pg level of

  10. Development of Large Sample Neutron Activation Technique for New Applications in Thailand

    International Nuclear Information System (INIS)

    Laoharojanaphand, S.; Tippayakul, C.; Wonglee, S.; Channuie, J.

    2018-01-01

    The development of the Large Sample Neutron Activation Analysis (LSNAA) in Thailand is presented in this paper. The technique had been firstly developed with rice sample as the test subject. The Thai Research Reactor-1/Modification 1 (TRR-1/M1) was used as the neutron source. The first step was to select and characterize an appropriate irradiation facility for the research. An out-core irradiation facility (A4 position) was first attempted. The results performed with the A4 facility were then used as guides for the subsequent experiments with the thermal column facility. The characterization of the thermal column was performed with Cu-wire to determine spatial distribution without and with rice sample. The flux depression without rice sample was observed to be less than 30% while the flux depression with rice sample increased to within 60%. The flux monitors internal to the rice sample were used to determine average flux over the rice sample. The gamma selfshielding effect during gamma measurement was corrected using the Monte Carlo simulation. The ratio between the efficiencies of the volume source and the point source for each energy point was calculated by the MCNPX code. The research team adopted the k0-NAA methodology to calculate the element concentration in the research. The k0-NAA program which developed by IAEA was set up to simulate the conditions of the irradiation and measurement facilities used in this research. The element concentrations in the bulk rice sample were then calculated taking into account the flux depression and gamma efficiency corrections. At the moment, the results still show large discrepancies with the reference values. However, more research on the validation will be performed to identify sources of errors. Moreover, this LS-NAA technique was introduced for the activation analysis of the IAEA archaeological mock-up. The results are provided in this report. (author)

  11. Les tüchlein et les succhi d’erba 

    Directory of Open Access Journals (Sweden)

    Aurélie Minet

    2010-11-01

    Full Text Available Les tüchlein et les succhi d’erba sont deux techniques de peinture sur toile qui suscitent la curiosité et le questionnement du grand public comme des spécialistes du patrimoine artistique. Dans le cadre d’un mémoire de fin d’études réalisé en 2009, ces deux techniques ont été confrontées du point de vue sémantique, technique et technologique. Une proposition de traitement à l’aide d’« éponges nanomagnétiques » fut également étudiée. Cet article présente la méthodologie utilisée lors de cette recherche et réalise une synthèse des résultats obtenus par les différentes investigations et expérimentations.The tüchlein and the succhi d’erba are two canvas painting techniques which have promoted great interest not only from the general public but also from expert specialized in artistic heritage. In 2009, the semantic, the technical and technological skills of the two techniques were examined. A suggested treatment for this type of work of art with “nanomagnetical sponges” was also studied. This article shows the methodology used in this research and combines the results obtained by the different experiments and investigations.

  12. Examination of Hydrate Formation Methods: Trying to Create Representative Samples

    Energy Technology Data Exchange (ETDEWEB)

    Kneafsey, T.J.; Rees, E.V.L.; Nakagawa, S.; Kwon, T.-H.

    2011-04-01

    Forming representative gas hydrate-bearing laboratory samples is important so that the properties of these materials may be measured, while controlling the composition and other variables. Natural samples are rare, and have often experienced pressure and temperature changes that may affect the property to be measured [Waite et al., 2008]. Forming methane hydrate samples in the laboratory has been done a number of ways, each having advantages and disadvantages. The ice-to-hydrate method [Stern et al., 1996], contacts melting ice with methane at the appropriate pressure to form hydrate. The hydrate can then be crushed and mixed with mineral grains under controlled conditions, and then compacted to create laboratory samples of methane hydrate in a mineral medium. The hydrate in these samples will be part of the load-bearing frame of the medium. In the excess gas method [Handa and Stupin, 1992], water is distributed throughout a mineral medium (e.g. packed moist sand, drained sand, moistened silica gel, other porous media) and the mixture is brought to hydrate-stable conditions (chilled and pressurized with gas), allowing hydrate to form. This method typically produces grain-cementing hydrate from pendular water in sand [Waite et al., 2004]. In the dissolved gas method [Tohidi et al., 2002], water with sufficient dissolved guest molecules is brought to hydrate-stable conditions where hydrate forms. In the laboratory, this is can be done by pre-dissolving the gas of interest in water and then introducing it to the sample under the appropriate conditions. With this method, it is easier to form hydrate from more soluble gases such as carbon dioxide. It is thought that this method more closely simulates the way most natural gas hydrate has formed. Laboratory implementation, however, is difficult, and sample formation is prohibitively time consuming [Minagawa et al., 2005; Spangenberg and Kulenkampff, 2005]. In another version of this technique, a specified quantity of gas

  13. Direct sampling technique of bees on Vriesea philippocoburgii (Bromeliaceae, Tillandsioideae flowers

    Directory of Open Access Journals (Sweden)

    Afonso Inácio Orth

    2004-11-01

    Full Text Available In our study on Vriesea philippocoburgii Wawra pollination, due to the small proportion of flowers in anthesis on a single day and the damage caused to inflorescences when netting directly on flowers, we used the direct sampling technique (DST of bees on flowers. This technique was applied to 40 flowering plants and resulted in the capture of 160 specimens, belonging to nine genera of Apoidea and separated into 19 morph species. As DST maintains the integrity of flowers for later Bees’ visits, it can enhance the survey’s performance, constituting an alternative methodology for the collection of bees visiting flowering plants.

  14. Pleine-conscience et management : effet de la mindfulness sur la relation au travail et le style de leadership des managers.

    OpenAIRE

    Françoise , Daniel

    2016-01-01

    Mindfulness is a fundamental concept which has existed since the dawn of time in meditative circles. These days it is a psychological construct that is the focus of much writing, and tested therapeutic technique, notably in stress reduction and in depressive relapse prevention (Bishop et al., 2004 ; Brown, Ryan et Creswell, 2007 ; Grossman et al., 2004). Mindfulness and its effects on management practice are the focus of a limited number of studies (Dane, 2010 ; Good et al., 2016). Our hypoth...

  15. Identification of unknown sample using NAA, EDXRF, XRD techniques

    International Nuclear Information System (INIS)

    Dalvi, Aditi A.; Swain, K.K.; Chavan, Trupti; Remya Devi, P.S.; Wagh, D.N.; Verma, R.

    2015-01-01

    Analytical Chemistry Division (ACD), Bhabha Atomic Research Centre (BARC) receives samples from law enforcement agencies such as Directorate of Revenue Intelligence, Customs for analysis. Five unknown grey powdered samples were received for identification and were suspected to be Iridium (Ir). Identification of unknown sample is always a challenging task and suitable analytical techniques have to be judiciously utilized for arriving at the conclusion. Qualitative analysis was carried out using Jordan Valley, EX-3600 M Energy dispersive X-ray fluorescence (EDXRF) spectrometer at ACD, BARC. A SLP series LEO Si (Li) detector (active area: 30 mm 2 ; thickness: 3.5 mm; resolution: 140 eV at 5.9 keV of Mn K X-ray) was used during the measurement and only characteristic X-rays of Ir (Lα: 9.17 keV and Lβ: 10.70 keV) was seen in the X-ray spectrum. X-ray diffraction (XRD) measurement results indicated that the Ir was in the form of metal. To confirm the XRD data, neutron activation analysis (NAA) was carried out by irradiating samples and elemental standards (as comparator) in graphite reflector position of Advanced Heavy Water Reactor Critical Facility (AHWR CF) reactor, BARC, Mumbai. After suitable decay period, gamma activity measurements were carried out using 45% HPGe detector coupled to 8 k multi channel analyzer. Characteristic gamma line at 328.4 keV of the activation product 194 Ir was used for quantification of iridium and relative method of NAA was used for concentration calculations. NAA results confirmed that all the samples were Iridium metal. (author)

  16. Development of SYVAC sampling techniques

    International Nuclear Information System (INIS)

    Prust, J.O.; Dalrymple, G.J.

    1985-04-01

    This report describes the requirements of a sampling scheme for use with the SYVAC radiological assessment model. The constraints on the number of samples that may be taken is considered. The conclusions from earlier studies using the deterministic generator sampling scheme are summarised. The method of Importance Sampling and a High Dose algorithm, which are designed to preferentially sample in the high dose region of the parameter space, are reviewed in the light of experience gained from earlier studies and the requirements of a site assessment and sensitivity analyses. In addition the use of an alternative numerical integration method for estimating risk is discussed. It is recommended that the method of Importance Sampling is developed and tested for use with SYVAC. An alternative numerical integration method is not recommended for investigation at this stage but should be the subject of future work. (author)

  17. La Commission électrotechnique internationale (CEI) et le Comité français (CEF). Normes et recommandations, 1948-1988

    OpenAIRE

    Machefert-Tassin, Yves

    2015-01-01

    La Commission électrotechnique internationale (CEI-IEC) dont le siège est à Genève (Suisse) a, entre autres, pour but de promouvoir pour ses membres une coopération internationale afin de normaliser et de coordonner les règles et recommandations que doivent remplir les différents matériels faisant partie des domaines de l’électrotechnique, de l’électronique et des techniques connexes. Ces normes internationales vont de la terminologie et des symboles ou vocabulaire à l’évaluation, par essais,...

  18. ONI-Asia - censure et surveillance numériques | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    La censure et la surveillance numériques, celles des communications par ... qui vise à mieux comprendre les aspects techniques et sociaux de la censure et de la ... Le nouveau site Web et la nouvelle bibliothèque de ressources aideront à ...

  19. Invention et interprétation : chants de boisson et chants chamaniques chez les Suruí du Rondônia

    OpenAIRE

    Yvinec, Cédric

    2014-01-01

    Invention et interprétation : chants de boisson et chants chamaniques chez les Suruí du Rondônia. Cet article examine les techniques rhétoriques mises en œuvre par deux genres de chants rituels des Suruí du Rondônia, chants de fête de boisson et chants chamaniques, notamment les écarts par lesquels la langue et l’énonciation rituelles se distinguent du discours ordinaire. Ces procédés rhétoriques trouvent un écho au niveau sociologique, à travers le statut du chamane et celui du grand homme d...

  20. Nonactivation interaction techniques in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.

    1986-01-01

    Nonactivation interaction analytical methods are based on the interaction processes of nuclear and X-ray radiation with a sample, leading to their absorption and backscattering, to the ionization of gases or excitation of fluorescent X-ray by radiation, but not to the activation of determined elements. From the point of view of environmental analysis, the most useful nonactivation interaction techniques are X-ray fluorescence by photon or charged particle excitation, ionization of gases by nuclear radiation, elastic scattering of charged particles and backscattering of beta radiation. The significant advantage of these methods is that they are nondestructive. (author)

  1. Enseignement technique/Technical Training

    CERN Multimedia

    1998-01-01

    Bureautique et techniques administratives/Office Automation & Administrative Techniques - Premiers pas/Getting started - E-Mail - Management Tools - WWW - Applications bureautiques/Office applications

  2. Comparison of Techniques for Sampling Adult Necrophilous Insects From Pig Carcasses.

    Science.gov (United States)

    Cruise, Angela; Hatano, Eduardo; Watson, David W; Schal, Coby

    2018-02-06

    Studies of the pre-colonization interval and mechanisms driving necrophilous insect ecological succession depend on effective sampling of adult insects and knowledge of their diel and successional activity patterns. The number of insects trapped, their diversity, and diel periodicity were compared with four sampling methods on neonate pigs. Sampling method, time of day and decomposition age of the pigs significantly affected the number of insects sampled from pigs. We also found significant interactions of sampling method and decomposition day, time of sampling and decomposition day. No single method was superior to the other methods during all three decomposition days. Sampling times after noon yielded the largest samples during the first 2 d of decomposition. On day 3 of decomposition however, all sampling times were equally effective. Therefore, to maximize insect collections from neonate pigs, the method used to sample must vary by decomposition day. The suction trap collected the most species-rich samples, but sticky trap samples were the most diverse, when both species richness and evenness were factored into a Shannon diversity index. Repeated sampling during the noon to 18:00 hours period was most effective to obtain the maximum diversity of trapped insects. The integration of multiple sampling techniques would most effectively sample the necrophilous insect community. However, because all four tested methods were deficient at sampling beetle species, future work should focus on optimizing the most promising methods, alone or in combinations, and incorporate hand-collections of beetles. © The Author(s) 2018. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Multi-element analysis of lubricant oil by WDXRF technique using thin-film sample preparation

    International Nuclear Information System (INIS)

    Scapin, M. A.; Salvador, V. L. R.; Lopes, C. D.; Sato, I. M.

    2006-01-01

    The quantitative analysis of the chemical elements in matrices like oils or gels represents a challenge for the analytical chemists. The classics methods or instrumental techniques such as atomic absorption spectrometry (AAS) and plasma optical emission spectrometry (ICP-OES) need chemical treatments, mainly sample dissolution and degradation processes. X-ray fluorescence technique allows a direct and multi-element analysis without previous sample treatments. In this work, a sensible method for the determination of elements Mg, Al, Si, P, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Mo, Ag, Sn, Ba and Pb in lubricating oil is presented. The x-ray fluorescence (WDXRF) technique using linear regression method and thin film sample preparation was used. The validation of the methodology (repeatability and accuracy) was obtained by the analysis of the standard reference materials SRM Alpha AESAR lot 703527D, applying the Chauvenet, Cochrane, ANOVA and Z-score statistical tests. The method presents a relative standard deviation lower than 10% for all the elements, except for Pb determination (RSD Pb 15%). The Z-score values for all the elements were in the range -2 < Z < 2, indicating a very good accuracy.(Full text)

  4. Human mixed lymphocyte cultures. Evaluation of microculture technique utilizing the multiple automated sample harvester (MASH)

    Science.gov (United States)

    Thurman, G. B.; Strong, D. M.; Ahmed, A.; Green, S. S.; Sell, K. W.; Hartzman, R. J.; Bach, F. H.

    1973-01-01

    Use of lymphocyte cultures for in vitro studies such as pretransplant histocompatibility testing has established the need for standardization of this technique. A microculture technique has been developed that has facilitated the culturing of lymphocytes and increased the quantity of cultures feasible, while lowering the variation between replicate samples. Cultures were prepared for determination of tritiated thymidine incorporation using a Multiple Automated Sample Harvester (MASH). Using this system, the parameters that influence the in vitro responsiveness of human lymphocytes to allogeneic lymphocytes have been investigated. PMID:4271568

  5. Optimized cryo-focused ion beam sample preparation aimed at in situ structural studies of membrane proteins.

    Science.gov (United States)

    Schaffer, Miroslava; Mahamid, Julia; Engel, Benjamin D; Laugks, Tim; Baumeister, Wolfgang; Plitzko, Jürgen M

    2017-02-01

    While cryo-electron tomography (cryo-ET) can reveal biological structures in their native state within the cellular environment, it requires the production of high-quality frozen-hydrated sections that are thinner than 300nm. Sample requirements are even more stringent for the visualization of membrane-bound protein complexes within dense cellular regions. Focused ion beam (FIB) sample preparation for transmission electron microscopy (TEM) is a well-established technique in material science, but there are only few examples of biological samples exhibiting sufficient quality for high-resolution in situ investigation by cryo-ET. In this work, we present a comprehensive description of a cryo-sample preparation workflow incorporating additional conductive-coating procedures. These coating steps eliminate the adverse effects of sample charging on imaging with the Volta phase plate, allowing data acquisition with improved contrast. We discuss optimized FIB milling strategies adapted from material science and each critical step required to produce homogeneously thin, non-charging FIB lamellas that make large areas of unperturbed HeLa and Chlamydomonas cells accessible for cryo-ET at molecular resolution. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Determination of anionic concentrations in ground water samples using ion chromatography

    International Nuclear Information System (INIS)

    Prathibha, P.; Saradhi, I.V.; Pandit, G.G.; Puranik, V.D.

    2011-01-01

    Ion chromatography is a powerful separation technique for the quantitative measurement of anions in aqueous samples as well as in soil, sediment and air particulate samples leached in aqueous solutions. Ion chromatographic technique is developed by making use of suppressed ion conductivity detection (Small et.al.,1975) and it is a rapid multi ion analysis technique. The time, processing and effort required for the analysis of anions is much less compared to other techniques available such as ion selective electrode technique. In the present paper ground water samples collected around New BARC campus, Visakhapatnam are analyzed for anions using Ion chromatograph. The data generated will establish the current baseline status of the ionic contaminants in the study area. Groundwater samples are collected at 13 locations around BARC Vizag campus covering 30 km radius in September, 2009, April and July, 2010. The water samples include samples from hand pump and open wells in villages. The water samples are analyzed for fluoride, chloride, nitrate and sulphate using Metrohm make Ion chromatograph. The fluoride concentration in samples varied from 0.22 to 1.26 ppm, chloride from 18.7 to 810.9, nitrate from 1.34 to 378.5 ppm and sulphate from 13.29 to 250.69 ppm. No significant seasonal variations are observed in the samples collected from various locations except chloride at two locations. Ions Chromatograph is found to be a useful tool for simultaneous analysis of environmental samples with good accuracy where the concentrations of anions vary within an order of magnitude among them themselves. (author)

  7. [Influence of Natural Dissolved Organic Matter on the Passive Sampling Technique and its Application].

    Science.gov (United States)

    Yu, Shang-yun; Zhou, Yan-mei

    2015-08-01

    This paper studied the effects of different concentrations of natural dissolved organic matter (DOM) on the passive sampling technique. The results showed that the presence of DOM affected the organic pollutant adsorption ability of the membrane. For lgK(OW), 3-5, DOM had less impact on the adsorption of organic matter by the membrane; for lgK(OW), > 5.5, DOM significantly increased the adsorption capacity of the membrane. Meanwhile, LDPE passive sampling technique was applied to monitor PAHs and PAEs in pore water of three surface sediments in Taizi River. All of the target pollutants were detected in varying degrees at each sampling point. Finally, the quotient method was used to assess the ecological risks of PAHs and PAEs. The results showed that fluoranthene exceeded the reference value of the aquatic ecosystem, meaning there was a big ecological risk.

  8. Technical and Economic Problems Associated with the Development of Methods of Processing and Using Radioactive Waste; Problemes techniques et economiques lies au developpement des methodes de traitement et d'utilisation des dechets radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Thiriet, L; Sauteron, J; Oger, C [Commissariat a l' Energie Atomique, Fontenay-Aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    The paper briefly reviews the various techniques used in processing the radioactive wastes which unavoidably result from the generation of electric power from nuclear sources. The paper goes on to define the relative importance, in nuclear fuel cycles, of the problem raised by these wastes. Emphasis is placed on the economic influence of management policies on the cost of power generation, and hence on the relative position of nuclear energy. A substantial percentage of these wastes can be economically utilized. Attention is drawn to the major technical and economic features of the industry which will come into being as a result of this utilization. The major uses anticipated are discussed: radiation sources, heat sources, auxiliary power generation. The paper concludes that satisfactory solutions have already been found to these problems, and describes possible improvements. (author) [French] La communication rappelle d'abord succinctement les differentes techniques de traitement des dechets radioactifs resultant necessairement de la production d'electricite d'origine nucleaire. On situe ensuite l'importance du probleme pose par ces residus dans le cycle du combustible nucleaire. On fait ressortir l'influence economique du choix des methodes de gestion sur le cout de production de l'energie, et par consequent sur la place devolue a l'energie nucleaire. Une part importante de ces dechets peut faire l'objet d'une utilisation rentable de l'industrie qui naitra de cette utilisation. Les principales applications envisagees sont evoquees: sources d'irradiation, sources chauffantes, generateurs auxiliaires d'energie. On conclut que d'ores et deja des solutions satisfaisantes ont ete apportees a ces problemes, et l'on decrit les perspectives d'amelioration concevables. (auteur)

  9. L'intervention sous-marine : situation actuelle et perspectives d'avenir Underwater Operations and Techniques: Current Situation and Future Outlook

    Directory of Open Access Journals (Sweden)

    Bertrand A. R. V.

    2006-11-01

    Full Text Available A l'occasion de la Conférence Internationale de Paris sur la Pénétration sous-marine(6-8 décembre 1982, cet article fait le point sur les différents moyens d'intervention sous-marine disponibles à ce jour (plongeurs, engins télécommandés, sous-marins à pression atmosphérique et sur un certain nombre de problèmes technologiques communs (matériaux, télémanipulation, navigation, sources d'énergie. Ce domaine est encore en pleine évolution et fait appel aux récentes innovations technologiques. Bien que les engins télécommandés semblent avoir actuellement la faveur des industriels, les autres moyens restent d'avenir prometteur, la complémentarité devant remplacer dans le futur la concurrence La résurrection de l'Argyronète qui doit devenir en 1985 un banc d'essais des nouvelles techniques est le témoignage de l'activité de ce secteur industriel. This article is based on the International Symposium in Paris on Underwater Operations and Techniques 6-9 December 1982. It reviews the different methods now available for underwater operations (divers, remote-controlled vehicles, atmospheric-pressure submarines and various technological problems common to all of them (materials, remote manipulation, navigating, power sources. This field is evolving rapidly and makes use of the most recent technological innovations. Although remote-controlled vehicles now seem to be favored by industrialists, the other methods still have a promising future, and the complementariness of these methods can be expected to replace rivalry among them. The resurrection of the Argyronète project, which should become a test bench for new techniques in 1985, is a good illustration of the activity going on in this industrial sector.

  10. Jean-Louis Déotte, Walter Benjamin et la forme plastique. Architecture, technique, lieux

    OpenAIRE

    Brabant, Dominik

    2014-01-01

    Une longue fréquentation de Walter Benjamin a permis à Jean-Louis Déotte de construire, progressivement, par touches successives et motifs récurrents sans cesse repris et retravaillés, une figure de l’œuvre qui n’en soit pas la simple exégèse toujours recommencée, mais bien la reconfiguration constante de son lieu, du site de son avoir-lieu, si l’on considère l’œuvre-Benjamin à l’image d’un événement. Walter Benjamin et la forme plastique constitue à cet égard une étape importante, sans postu...

  11. Heating and thermal control of brazing technique to break contamination path for potential Mars sample return

    Science.gov (United States)

    Bao, Xiaoqi; Badescu, Mircea; Sherrit, Stewart; Bar-Cohen, Yoseph; Campos, Sergio

    2017-04-01

    The potential return of Mars sample material is of great interest to the planetary science community, as it would enable extensive analysis of samples with highly sensitive laboratory instruments. It is important to make sure such a mission concept would not bring any living microbes, which may possibly exist on Mars, back to Earth's environment. In order to ensure the isolation of Mars microbes from Earth's Atmosphere, a brazing sealing and sterilizing technique was proposed to break the Mars-to-Earth contamination path. Effectively, heating the brazing zone in high vacuum space and controlling the sample temperature for integrity are key challenges to the implementation of this technique. The break-thechain procedures for container configurations, which are being considered, were simulated by multi-physics finite element models. Different heating methods including induction and resistive/radiation were evaluated. The temperature profiles of Martian samples in a proposed container structure were predicted. The results show that the sealing and sterilizing process can be controlled such that the samples temperature is maintained below the level that may cause damage, and that the brazing technique is a feasible approach to breaking the contamination path.

  12. Texture investigation in aluminium and iron - silicon samples by neutron diffraction technique

    International Nuclear Information System (INIS)

    Pugliese, R.; Yamasaki, J.M.

    1988-09-01

    By means of the neutron diffraction technique the texture of 5% and 98% rolled-aluminium and of iron-silicon steel used in the core of electric transformers, have been determined. The measurements were performed by using a neutron diffractometer installed at the IEA-R1 Nuclear Research Reactor, in the Beam-Hole n 0 . 6. To avoid corrections such as neutron absorption and sample luminosity the geometric form of the samples were approximated to spheric or octagonal prism, and its dimensions do not exceed that of the neutron beam. The texture of the samples were analysed with the help of a computer programme that analyses the intensity of the diffracted neutron beam and plot the pole figures. (author) [pt

  13. Enseignement technique : Séminaire de l'enseigement technique

    CERN Multimedia

    2004-01-01

    Mardi 4 mai 2004 SEMINAIRE DE L'ENSEIGNEMENT TECHNIQUE de 14:00 à 17:00 - Training Centre Auditorium - bât. 593 Le SPC - Statistical Process Control - dans une démarche de qualité totale Hakim Bourahla, Maurice Arrius, Charbel Tannous - ABW Concept - F-74950 SCIONZIER, France Ce nouveau séminaire de l'Enseignement Technique sera consacré à la présentation du SPC, le Statistical Process Control. Le SPC apporte une grande efficacité dans l'amélioration de la qualité des produits. Cette méthode, permettant d'assurer une qualité optimum à l'aide d'un outil statistique, est fondée sur deux concepts de base : le suivi et le pilotage des procédés industriels par cartes de contrôle, et l'étude des capabilités des systèmes de production. - Origine et objectifs du SPC - Concepts du ...

  14. Enseignement technique : Séminaire de l'enseignement technique

    CERN Multimedia

    2004-01-01

    Mardi 4 mai 2004 SEMINAIRE DE L'ENSEIGNEMENT TECHNIQUE de 14:00 à 17:00 - Training Centre Auditorium - bât. 593 Le SPC - Statistical Process Control - dans une démarche de qualité totale Hakim Bourahla, Maurice Arrius, Charbel Tannous - ABW Concept - F-74950 SCIONZIER, France Ce nouveau séminaire de l'Enseignement Technique sera consacré à la présentation du SPC, le Statistical Process Control. Le SPC apporte une grande efficacité dans l'amélioration de la qualité des produits. Cette méthode, permettant d'assurer une qualité optimum à l'aide d'un outil statistique, est fondée sur deux concepts de base : le suivi et le pilotage des procédés industriels par cartes de contrôle, et l'étude des capabilités des systèmes de production. - Origine et objectifs du SPC - Concepts du ...

  15. The particle analysis based on FT-TIMS technique for swipe sample under the frame of nuclear safeguard

    International Nuclear Information System (INIS)

    Yang Tianli; Liu Xuemei; Liu Zhao; Tang Lei; Long Kaiming

    2008-06-01

    Under the frame of nuclear safeguard, the particles analysis for swipe sample is an advance mean to detect the undeclared uranium enriched facilities and undeclared uranium enriched activity. The technique of particle analysis based on fission track-thermal ionization mass spectrometry (FT-TIMS) for swipe sample have been built. The reliability and the experimental background for selecting particles consisting of uranium from swipe sample by FT method have been verified. In addition, the utilization coefficient of particles on the surface of swipe sample have also been tested. These works have provided the technique support for application in the area of nuclear verification. (authors)

  16. PRIMUS: INFRARED AND X-RAY AGN SELECTION TECHNIQUES AT 0.2 < z < 1.2

    Energy Technology Data Exchange (ETDEWEB)

    Mendez, Alexander J.; Coil, Alison L.; Aird, James; Diamond-Stanic, Aleksandar M. [Center for Astrophysics and Space Sciences, Department of Physics, University of California, 9500 Gilman Dr., La Jolla, San Diego, CA 92093 (United States); Moustakas, John [Department of Physics and Astronomy, Siena College, 515 Loudon Road, Loudonville, NY 12211 (United States); Blanton, Michael R. [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Cool, Richard J. [Observatories of the Carnegie Institution for Science, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Eisenstein, Daniel J. [Harvard College Observatory, 60 Garden St., Cambridge, MA 02138 (United States); Wong, Kenneth C. [Steward Observatory, University of Arizona, 933 N. Cherry Ave., Tucson, AZ 85721 (United States); Zhu Guangtun [Department of Physics and Astronomy, Johns Hopkins University, 3400 N. Charles Street, Baltimore, MD 21218 (United States)

    2013-06-10

    We present a study of Spitzer/IRAC and X-ray active galactic nucleus (AGN) selection techniques in order to quantify the overlap, uniqueness, contamination, and completeness of each. We investigate how the overlap and possible contamination of the samples depend on the depth of both the IR and X-ray data. We use Spitzer/IRAC imaging, Chandra and XMM-Newton X-ray imaging, and spectroscopic redshifts from the PRism MUlti-object Survey to construct galaxy and AGN samples at 0.2 < z < 1.2 over 8 deg{sup 2}. We construct samples over a wide range of IRAC flux limits (SWIRE to GOODS depth) and X-ray flux limits (10 ks to 2 Ms). We compare IR-AGN samples defined using both the IRAC color selection of Stern et al. and Donley et al. with X-ray-detected AGN samples. For roughly similar depth IR and X-ray surveys, we find that {approx}75% of IR-selected AGNs are also identified as X-ray AGNs. This fraction increases to {approx}90% when comparing against the deepest X-ray data, indicating that at most {approx}10% of IR-selected AGNs may be heavily obscured. The IR-AGN selection proposed by Stern et al. suffers from contamination by star-forming galaxies at various redshifts when using deeper IR data, though the selection technique works well for shallow IR data. While similar overall, the IR-AGN samples preferentially contain more luminous AGNs, while the X-ray AGN samples identify a wider range of AGN accretion rates including low specific accretion rate AGNs, where the host galaxy light dominates at IR wavelengths. The host galaxy populations of the IR and X-ray AGN samples have similar rest-frame colors and stellar masses; both selections identify AGNs in blue, star-forming and red, quiescent galaxies.

  17. Croissance des couches minces et des multicouches de matériaux supraconducteurs H Tboldmath_c : bilan et perspective

    Science.gov (United States)

    Contour, J. P.

    1994-11-01

    The main physical and chemical techniques of epitaxial growth of High T_c superconductor thin films are described together with their in situ analysis facilities and discussed with respect to their cost, sophistication and results (T_c, J_c growth defects, thickness and composition uniformity, crystallinity, electronic applications...). The future trends of the growth machines are then examined in connection with the present results and the development of superconductor electronics. Après la présentation des principales techniques de croissance physique et physicochimique de couches minces d'oxydes supraconducteurs à haute température critique, un bilan des résultats sera dressé par rapport aux différentes propriétés des films (transition résistive, courant critique, défauts de croissance, uniformité d'épaisseur et de composition, cristallinité...), aux difficultés de mise en œuvre et au coût de l'expérience. Les perspectives des différentes techniques seront ensuite examinées dans le cadre du développement potentiel d'une électronique utilisant les matériaux supraconducteurs H T_c.

  18. Dosimetric characterization of BeO samples in alpha, beta and X radiation beams using luminescent techniques

    International Nuclear Information System (INIS)

    Groppo, Daniela Piai

    2013-01-01

    In the medical field, the ionizing radiation is used both for therapeutic and diagnostic purposes, in a wide range of radiation doses. In order to ensure that the objective is achieved in practice, detailed studies of detectors and devices in different types of radiations beams are necessary. In this work a dosimetric characterization of BeO samples was performed using the techniques of thermoluminescence (TL) and optically stimulated luminescence (OSL) by a comparison of their response for alpha, beta and X radiations and the establishment of an appropriated system for use in monitoring of these radiations beams. The main results are: the high sensitivity to beta radiation for both techniques, good reproducibility of TL and OSL response (coefficients of variation lower than 5%), maximum energy dependence of the X radiation of 28% for the TL technique, and only 7% for the OSL technique, within the studied energy range. The dosimetric characteristics obtained in this work show the possibility of applying BeO samples to dosimetry of alpha, beta and X radiations, considering the studied dose ranges, using the TL and OSL techniques. From the results obtained, the samples of BeO showed their potential use for beam dosimetry in diagnostic radiology and radiotherapy. (author)

  19. Genèse du nouveau master « Histoire des sciences et techniques, humanités numériques et médiations culturelles » : de l'articulation entre la recherche et la formation au Centre François Viète de l'Université de Bretagne Occidentale

    Directory of Open Access Journals (Sweden)

    Chambon Gregory

    2014-01-01

    Full Text Available L'objet de cet article est de montrer comment la dynamique de création simultanée, à Brest et depuis 2008, d'une nouvelle équipe de recherche et d'un nouveau master recherche à distance en 2012 s'est traduit par une proposition originale de formation par la recherche. Nous détaillons les spécificités de cette dernière. D'une part, elle prend fortement appui sur des axes de recherches et des nouvelles méthodologies en histoire des sciences et des techniques, qui s'inspirent des travaux sur la culture matérielle et la compréhension des systèmes complexes. En outre, nous montrons que des questions de recherche et de formation y sont intégrées concernant le développement ou l'usage des outils numériques (web sémantique, réalité virtuelle ou augmentée, etc. pour la recherche en SHS et médiations culturelles. L'équipe de Brest s'inscrit de ce fait dans le champ des travaux de recherches en humanités numériques en très forte collaboration avec notamment des laboratoires d'informatique. Au travers des thématiques traitées, des méthodologies enseignées, d'une pédagogie universitaire basée sur une classe virtuelle ainsi que de la nature des différents partenaires qui y enseignent, nous montrons ainsi que le master en question constituent un laboratoire où il est possible d'expérimenter de nouvelles pratiques de formation par la recherche.

  20. Long-term monitoring of the Danube river-Sampling techniques, radionuclide metrology and radioecological assessment

    International Nuclear Information System (INIS)

    Maringer, F.J.; Gruber, V.; Hrachowitz, M.; Baumgartner, A.; Weilner, S.; Seidel, C.

    2009-01-01

    Sampling techniques and radiometric methods, developed and applied in a comprehensive radioecological study of the Danube River are presented. Results and radiometric data of sediment samples, collected by sediment traps in Austria and additionally by grab sampling in the Danube during research cruises between Germany and the delta (Black sea) are shown and discussed. Goal of the investigation is the protection of public and environment, especially the sustainable use and conservation of human freshwater resources against harmful radioactive exposure.

  1. Separation of arsenic species by capillary electrophoresis with sample-stacking techniques

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zu Liang; Naidu, Ravendra [Adelaide Laboratory, CSIRO Land and Water, PMB2, 5064, Glen Osmond, SA (Australia); Lin, Jin-Ming [Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, 100085, Beijing (China)

    2003-03-01

    A simple capillary zone electrophoresis procedure was developed for the separation of arsenic species (AsO{sub 2}{sup 2-}, AsO{sub 4}{sup 2-}, and dimethylarsinic acid, DMA). Both counter-electroosmotic and co-electroosmotic (EOF) modes were investigated for the separation of arsenic species with direct UV detection at 185 nm using 20 mmol L{sup -1} sodium phosphate as the electrolyte. The separation selectivity mainly depends on the separation modes and electrolyte pH. Inorganic anions (Cl{sup -}, NO{sub 2}{sup -}, NO{sub 3}{sup -} and SO{sub 4}{sup 2-}) presented in real samples did not interfere with arsenic speciation in either separation mode. To improve the detection limits, sample-stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were investigated for the preconcentration of As species in co-CZE mode. Less than 1 {mu}mol L{sup -1} of detection limits for As species were achieved using FASI. The proposed method was demonstrated for the separation and detection of As species in water. (orig.)

  2. Decomposition and (importance) sampling techniques for multi-stage stochastic linear programs

    Energy Technology Data Exchange (ETDEWEB)

    Infanger, G.

    1993-11-01

    The difficulty of solving large-scale multi-stage stochastic linear programs arises from the sheer number of scenarios associated with numerous stochastic parameters. The number of scenarios grows exponentially with the number of stages and problems get easily out of hand even for very moderate numbers of stochastic parameters per stage. Our method combines dual (Benders) decomposition with Monte Carlo sampling techniques. We employ importance sampling to efficiently obtain accurate estimates of both expected future costs and gradients and right-hand sides of cuts. The method enables us to solve practical large-scale problems with many stages and numerous stochastic parameters per stage. We discuss the theory of sharing and adjusting cuts between different scenarios in a stage. We derive probabilistic lower and upper bounds, where we use importance path sampling for the upper bound estimation. Initial numerical results turned out to be promising.

  3. Monitoring of persistent organic pollutants in seawater of the Pearl River Estuary with rapid on-site active SPME sampling technique

    International Nuclear Information System (INIS)

    Huang, Siming; He, Shuming; Xu, Hao; Wu, Peiyan; Jiang, Ruifen; Zhu, Fang; Luan, Tiangang; Ouyang, Gangfeng

    2015-01-01

    An on-site active solid-phase microextraction (SPME) sampling technique coupled with gas chromatography-mass spectrometry (GC–MS) for sampling and monitoring 16 polycyclic aromatic hydrocarbons (PAHs) and 8 organochlorine pesticides (OCPs) in seawater was developed. Laboratory experiments demonstrated that the sampling-rate calibration method was practical and could be used for the quantification of on-site sampling. The proposed method was employed for field tests which covered large amounts of water samples in the Pearl River Estuary in rainy and dry seasons. The on-site SPME sampling method can avoid the contamination of sample, the losses of analytes during sample transportation, as well as the usage of solvent and time-consuming sample preparation process. Results indicated that the technique with the designed device can address the requirement of modern environment water analysis. In addition, the sources, bioaccumulation and potential risk to human of the PAHs and OCPs in seawater of the Pearl River Estuary were discussed. - Highlights: • SPME on-site active sampling technique was developed and validated. • The technique was employed for field tests in the Pearl River Estuary. • 16 PAHs and 8 OCPs in the seawater of Pearl River Estuary were monitored. • The potential risk of the PAHs and OCPs in Pearl River Estuary were discussed. - An on-site active SPME sampling technique was developed and successfully applied for sampling and monitoring 16 PAHs and 8 OCPs in the Pearl River Estuary

  4. Prompt Gamma Activation Analysis (PGAA): Technique of choice for nondestructive bulk analysis of returned comet samples

    International Nuclear Information System (INIS)

    Lindstrom, D.J.; Lindstrom, R.M.

    1989-01-01

    Prompt gamma activation analysis (PGAA) is a well-developed analytical technique. The technique involves irradiation of samples in an external neutron beam from a nuclear reactor, with simultaneous counting of gamma rays produced in the sample by neutron capture. Capture of neutrons leads to excited nuclei which decay immediately with the emission of energetic gamma rays to the ground state. PGAA has several advantages over other techniques for the analysis of cometary materials: (1) It is nondestructive; (2) It can be used to determine abundances of a wide variety of elements, including most major and minor elements (Na, Mg, Al, Si, P, K, Ca, Ti, Cr, Mn, Fe, Co, Ni), volatiles (H, C, N, F, Cl, S), and some trace elements (those with high neutron capture cross sections, including B, Cd, Nd, Sm, and Gd); and (3) It is a true bulk analysis technique. Recent developments should improve the technique's sensitivity and accuracy considerably

  5. Multielemental neutron activation analysis of some egyptian cement samples

    International Nuclear Information System (INIS)

    Eissa, E.A.; Rofail, N.B.; Abdel-Basset, N.; Soroor, A.; Hassan, A.M.

    1996-01-01

    Multielemental analysis of normal, Karnak and sea-water cement samples were performed by neutron activation analysis technique using the (ET-R R-1) reactor for sample irradiation. The Data were collected and analysed by means of the (HPGe) detection system and a Pca computer. A total of 23 elements namely, Na, A1, C 1, K, Ca, Sc, Cr, Mn, Fe, Co, Zn, Sr, Ba, La, Sm, Eu, Yb, Lu, Ta, Au, Th and U were identified and analysed with concentrations ranging from 1 ppm upto 62% a comparison between the elemental concentrations of the three cement types is given. 2 tabs

  6. Experimental study of laser ablation as sample introduction technique for inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Van Winckel, S.

    2001-01-01

    The contribution consists of an abstract of a PhD thesis. In the PhD study, several complementary applications of laser-ablation were investigated in order to characterise experimentally laser ablation (LA) as a sample introduction technique for ICP-MS. Three applications of LA as a sample introduction technique are discussed: (1) the microchemical analysis of the patina of weathered marble; (2) the possibility to measure isotope ratios (in particular Pb isotope ratios in archaeological bronze artefacts); and (3) the determination of Si in Al as part of a dosimetric study of the BR2 reactor vessel

  7. Experimental and theoretical contributions to X-ray phase-contrast techniques for medical imaging; Contributions experimentales et theoriques aux techniques de contraste de phase pour l'imagerie medicale par rayons X

    Energy Technology Data Exchange (ETDEWEB)

    Diemoz, P.C.

    2011-02-28

    Several X-ray phase-contrast techniques have recently been developed. Unlike conventional X-ray methods, which measure the absorption properties of the tissues, these techniques derive contrast also from the modulation of the phase produced by the sample. Since the phase shift can be significant even for small details characterized by weak or absent absorption, the achievable image contrast can be greatly increased, notably for the soft biological tissues. These methods are therefore very promising for applications in the medical domain. The aim of this work is to contribute to a deeper understanding of these techniques, in particular propagation-based imaging (PBI), analyzer-based imaging (ABI) and grating interferometry (GIFM), and to study their potential and the best practical implementation for medical imaging applications. An important part of this work is dedicated to the use of mathematical algorithms for the extraction, from the acquired images, of quantitative sample information (the absorption, refraction and scattering sample properties). In particular, five among the most known algorithms based on the geometrical optics approximation have been theoretically analysed and experimentally compared, in planar and tomographic modalities, by using geometrical phantoms and human bone-cartilage and breast samples. A semi-quantitative method for the acquisition and reconstruction of tomographic images in the ABI and GIFM techniques has also been proposed. The validity conditions are analyzed in detail and the method, enabling a considerable simplification of the imaging procedure, has been experimentally checked on phantoms and human samples. Finally, a theoretical and experimental comparison of the PBI, ABI and GIFM techniques is presented. The advantages and drawbacks of each of these techniques are discussed. The results obtained from this analysis can be very useful for determining the most adapted technique for a given application. (author)

  8. APPRENTISSAGES TECHNIQUES - Électronicien(ne) et laborantin(e) en physique - French version only

    CERN Multimedia

    2006-01-01

    GESTION ET DEVELOPPEMENT DU PERSONNEL HR/PMD L'APPRENTISSAGE AU CERN pour les professions d'électronicien(ne) et de laborantin(e) en physique L'apprentissage au CERN est régi par les lois, règlements et contrats en vigueur dans le canton de Genève. En cas de réussite à l'examen de fin d'apprentissage, les apprentis obtiennent le Certificat Fédéral de Capacité suisse (CFC). 6 places au total sont ouvertes au recrutement pour les deux professions. L'apprentissage dure 4 ans. Minima requis pour faire acte de candidature: avoir au moins 15 ans et moins de 21 ans à la date de début de l'apprentissage, avoir terminé la scolarité obligatoire, au minimum 9e du Cycle d'orientation genevois (3e en France), être ressortissant d'un pays membre du CERN (Allemagne, Autriche, Belgique, Bulgarie, Danemark, Espagne, Finlande, France, Grèce, Hongrie, Italie, Norvège, Pays-Bas, Pologne, Portugal, Royaume-Uni, République tchèque, République slovaque , Suède, Suisse), pour les résidents en Suisse :...

  9. Determination of metals in air samples using X-Ray fluorescence associated the APDC preconcentration technique

    Energy Technology Data Exchange (ETDEWEB)

    Nardes, Raysa C.; Santos, Ramon S.; Sanches, Francis A.C.R.A.; Gama Filho, Hamilton S.; Oliveira, Davi F.; Anjos, Marcelino J., E-mail: rc.nardes@gmail.com, E-mail: ramonziosp@yahoo.com.br, E-mail: francissanches@gmail.com, E-mail: hamiltongamafilho@hotmail.com, E-mail: davi.oliveira@uerj.br, E-mail: marcelin@uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Instituto de Fisica. Departamento de Fisica Aplicada e Termodinamica

    2015-07-01

    Air pollution has become one of the leading quality degradation factors of life for people in large urban centers. Studies indicate that the suspended particulate matter in the atmosphere is directly associated with risks to public health, in addition, it can cause damage to fauna, flora and public / cultural patrimonies. The inhalable particulate materials can cause the emergence and / or worsening of chronic diseases related to respiratory system and other diseases, such as reduced physical strength. In this study, we propose a new method to measure the concentration of total suspended particulate matter (TSP) in the air using an impinger as an air cleaning apparatus, preconcentration with APDC and Total Reflection X-ray Fluorescence technique (TXRF) to analyze the heavy metals present in the air. The samples were collected from five random points in the city of Rio de Janeiro/Brazil. Analyses of TXRF were performed at the Brazilian Synchrotron Light Laboratory (LNLS). The technique proved viable because it was able to detect five important metallic elements to environmental studies: Cr, Fe, Ni, Cu and Zn. This technique presented substantial efficiency in determining the elementary concentration of air pollutants, in addition to low cost. It can be concluded that the metals analysis technique in air samples using an impinger as sample collection instrument associated with a complexing agent (APDC) was viable because it is a low-cost technique, moreover, it was possible the detection of five important metal elements in environmental studies associated with industrial emissions and urban traffic. (author)

  10. Determination of metals in air samples using X-Ray fluorescence associated the APDC preconcentration technique

    International Nuclear Information System (INIS)

    Nardes, Raysa C.; Santos, Ramon S.; Sanches, Francis A.C.R.A.; Gama Filho, Hamilton S.; Oliveira, Davi F.; Anjos, Marcelino J.

    2015-01-01

    Air pollution has become one of the leading quality degradation factors of life for people in large urban centers. Studies indicate that the suspended particulate matter in the atmosphere is directly associated with risks to public health, in addition, it can cause damage to fauna, flora and public / cultural patrimonies. The inhalable particulate materials can cause the emergence and / or worsening of chronic diseases related to respiratory system and other diseases, such as reduced physical strength. In this study, we propose a new method to measure the concentration of total suspended particulate matter (TSP) in the air using an impinger as an air cleaning apparatus, preconcentration with APDC and Total Reflection X-ray Fluorescence technique (TXRF) to analyze the heavy metals present in the air. The samples were collected from five random points in the city of Rio de Janeiro/Brazil. Analyses of TXRF were performed at the Brazilian Synchrotron Light Laboratory (LNLS). The technique proved viable because it was able to detect five important metallic elements to environmental studies: Cr, Fe, Ni, Cu and Zn. This technique presented substantial efficiency in determining the elementary concentration of air pollutants, in addition to low cost. It can be concluded that the metals analysis technique in air samples using an impinger as sample collection instrument associated with a complexing agent (APDC) was viable because it is a low-cost technique, moreover, it was possible the detection of five important metal elements in environmental studies associated with industrial emissions and urban traffic. (author)

  11. A radioanalytical technique using (n,2n) reaction for the elemental analysis of samples

    International Nuclear Information System (INIS)

    Labor, M.

    1985-11-01

    A technique to determine elemental composition of samples is reported. The principle of the technique employs the internal standard method and involves the resolution of complex annihilation spectra. The technique has been applied to the determination of the mass of nitrogen, msub(N), and that of potassium, msub(K), in known masses of potassium nitrate. The percentage difference between the calculated mass and actual masses in 2g and 3g of potassium nitrate is 1.0 and 0.7 respectively for potassium, and 1.0 for nitrogen. The use of more simultaneous equations than necessary in solving for msub(N) and msub(K) offers one of the advantages of the technique. (author)

  12. Nuclear techniques in food and agriculture and international cooperation in their use; Les sciences nucleaires dans l'alimentation et l'agriculture et la cooperation internationale dans ce domaine

    Energy Technology Data Exchange (ETDEWEB)

    Fried, M.; Sigurbjörnsson, B. [Joint FAO/IAEA Division of Atomic Energy in Food and Agriculture, International Atomic Energy Agency, Vienna (Austria)

    1970-01-15

    des recherches coordonnées effectuées sous contrats ou accords de recherche. Une grande partie du travail se fait aussi dans le cadre de projets d'assistance technique, comprenant des services d'experts, la fourniture de matériel et la formation technique, ainsi que dans le cadre de deux projets du Fonds spécial du PNUD exécutés par l'AIEA. Le Laboratoire de l'AIEA, enfin, joue un rôle indispensable dans l'exécution de programmes de la Division en assurant une coordination, en faisant des recherches et en dispensant une formation spécialisée. (author)

  13. A novel non-invasive diagnostic sampling technique for cutaneous leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Yasaman Taslimi

    2017-07-01

    Full Text Available Accurate diagnosis of cutaneous leishmaniasis (CL is important for chemotherapy and epidemiological studies. Common approaches for Leishmania detection involve the invasive collection of specimens for direct identification of amastigotes by microscopy and the culturing of promastigotes from infected tissues. Although these techniques are highly specific, they require highly skilled health workers and have the inherent risks of all invasive procedures, such as pain and risk of bacterial and fungal super-infection. Therefore, it is essential to reduce discomfort, potential infection and scarring caused by invasive diagnostic approaches especially for children. In this report, we present a novel non-invasive method, that is painless, rapid and user-friendly, using sequential tape strips for sampling and isolation of DNA from the surface of active and healed skin lesions of CL patients. A total of 119 patients suspected of suffering from cutaneous leishmaniasis with different clinical manifestations were recruited and samples were collected both from their lesions and from uninfected areas. In addition, 15 fungal-infected lesions and 54 areas of healthy skin were examined. The duration of sampling is short (less than one minute and species identification by PCR is highly specific and sensitive. The sequential tape stripping sampling method is a sensitive, non-invasive and cost-effective alternative to traditional diagnostic assays and it is suitable for field studies as well as for use in health care centers.

  14. Use of X-ray diffraction technique and chemometrics to aid soil sampling strategies in traceability studies.

    Science.gov (United States)

    Bertacchini, Lucia; Durante, Caterina; Marchetti, Andrea; Sighinolfi, Simona; Silvestri, Michele; Cocchi, Marina

    2012-08-30

    Aim of this work is to assess the potentialities of the X-ray powder diffraction technique as fingerprinting technique, i.e. as a preliminary tool to assess soil samples variability, in terms of geochemical features, in the context of food geographical traceability. A correct approach to sampling procedure is always a critical issue in scientific investigation. In particular, in food geographical traceability studies, where the cause-effect relations between the soil of origin and the final foodstuff is sought, a representative sampling of the territory under investigation is certainly an imperative. This research concerns a pilot study to investigate the field homogeneity with respect to both field extension and sampling depth, taking also into account the seasonal variability. Four Lambrusco production sites of the Modena district were considered. The X-Ray diffraction spectra, collected on the powder of each soil sample, were treated as fingerprint profiles to be deciphered by multivariate and multi-way data analysis, namely PCA and PARAFAC. The differentiation pattern observed in soil samples, as obtained by this fast and non-destructive analytical approach, well matches with the results obtained by characterization with other costly analytical techniques, such as ICP/MS, GFAAS, FAAS, etc. Thus, the proposed approach furnishes a rational basis to reduce the number of soil samples to be collected for further analytical characterization, i.e. metals content, isotopic ratio of radiogenic element, etc., while maintaining an exhaustive description of the investigated production areas. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Revue d'Information Scientifique et Technique - Vol 5, No 1 (1995)

    African Journals Online (AJOL)

    COCACOM : environnement de développement d'applications coopérantes et multimédia · EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. J-M. Inglebert, L Courtrai, S Sadou ...

  16. Sample preparation for large-scale bioanalytical studies based on liquid chromatographic techniques.

    Science.gov (United States)

    Medvedovici, Andrei; Bacalum, Elena; David, Victor

    2018-01-01

    Quality of the analytical data obtained for large-scale and long term bioanalytical studies based on liquid chromatography depends on a number of experimental factors including the choice of sample preparation method. This review discusses this tedious part of bioanalytical studies, applied to large-scale samples and using liquid chromatography coupled with different detector types as core analytical technique. The main sample preparation methods included in this paper are protein precipitation, liquid-liquid extraction, solid-phase extraction, derivatization and their versions. They are discussed by analytical performances, fields of applications, advantages and disadvantages. The cited literature covers mainly the analytical achievements during the last decade, although several previous papers became more valuable in time and they are included in this review. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Use of an oscillation technique to measure effective cross-sections of fissionable samples in critical assemblies

    International Nuclear Information System (INIS)

    Tretiakoff, O.; Vidal, R.; Carre, J.C.; Robin, M.

    1964-01-01

    The authors describe the technique used to measure the effective absorption and neutron-yield cross-sections of a fissionable sample. These two values are determined by analysing the signals due to the variation in reactivity (over-all signal) and the local perturbation in the flux (local signal) produced by the oscillating sample. These signals are standardized by means of a set of samples containing quantities of fissionable material ( 235 U) and an absorber, boron, which are well known. The measurements are made for different neutron spectra characterized by lattice parameters which constitute the central zone within which the sample moves. This technique is used to study the effective cross-sections of uranium-plutonium alloys for different heavy-water and graphite lattices in the MINERVE and MARIUS critical assemblies. The same experiments are carried out on fuel samples of different irradiations in order to determine the evolution of effective cross-sections as a function of the spectrum and the irradiations. (authors) [fr

  18. Toward greener analytical techniques for the absolute quantification of peptides in pharmaceutical and biological samples.

    Science.gov (United States)

    Van Eeckhaut, Ann; Mangelings, Debby

    2015-09-10

    Peptide-based biopharmaceuticals represent one of the fastest growing classes of new drug molecules. New reaction types included in the synthesis strategies to reduce the rapid metabolism of peptides, along with the availability of new formulation and delivery technologies, resulted in an increased marketing of peptide drug products. In this regard, the development of analytical methods for quantification of peptides in pharmaceutical and biological samples is of utmost importance. From the sample preparation step to their analysis by means of chromatographic or electrophoretic methods, many difficulties should be tackled to analyze them. Recent developments in analytical techniques emphasize more and more on the use of green analytical techniques. This review will discuss the progresses in and challenges observed during green analytical method development for the quantification of peptides in pharmaceutical and biological samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Ionophorèse et électroporation : administration cutanée de médicaments et d'ADN

    OpenAIRE

    Préat, Véronique; Vandermeulen, Gaëlle; Daugimont, Liévin; Wascotte, Valentine

    2009-01-01

    La peau est une cible intéressante pour l'administration de médicaments et d'ADN qui cependant reste limitée par la faible perméabilité du stratum corneum. L'ionophorèse et l'électroporation ont été largement étudiées afin d'obtenir une administration transdermique. Dans les deux cas, le passage de courant perturbe la perméabilité de la peau et même la perméabilité cellulaire dans le cas précis de l'électroporation. Ces deux techniques permettent d'élargir le spectre des substances administra...

  20. Elemental analysis and plant samples at el-Manzala lake by neutron activation analysis technique

    Energy Technology Data Exchange (ETDEWEB)

    Eissa, E A; Rofail, N B; Abdel-Haleem, A S; El-Abbady, W H; Hassan, A M [Arab Republic of Egypt, Atomic energy Authority, Reactor and Neutron Physiscs Department, Cairo (Egypt)

    1996-12-31

    A soil and a plant samples were taken from two locations, Bahr el-Bakar and Bahr Kados at the Manzala lake, where a high pollution is expected. The samples were especially treated and prepared for investigation by thermal neutron activation analysis (NAA). The irradiation facilities of the first egyptian research reactor (ET-R R-1) and the hyper pure germanium (HPGe) detection system were used for such a type of analysis. Among the 34 identified elements Fe, Co, As, Ru, Cd, Te, La, Sm, Eu, Tb, Hg, Th, and U are of a special significance because of their toxic deleterious impact to organisms. This work is a part of a research project concerning pollution studies on the river nile and some lakes of egypt. The data obtained in the present work stand as a reference basic record for any future follow up of the contamination level. 1 tab.

  1. Elemental analysis and plant samples at el-Manzala lake by neutron activation analysis technique

    International Nuclear Information System (INIS)

    Eissa, E.A.; Rofail, N.B.; Abdel-Haleem, A.S.; El-Abbady, W.H.; Hassan, A.M.

    1995-01-01

    A soil and a plant samples were taken from two locations, Bahr el-Bakar and Bahr Kados at the Manzala lake, where a high pollution is expected. The samples were especially treated and prepared for investigation by thermal neutron activation analysis (NAA). The irradiation facilities of the first egyptian research reactor (ET-R R-1) and the hyper pure germanium (HPGe) detection system were used for such a type of analysis. Among the 34 identified elements Fe, Co, As, Ru, Cd, Te, La, Sm, Eu, Tb, Hg, Th, and U are of a special significance because of their toxic deleterious impact to organisms. This work is a part of a research project concerning pollution studies on the river nile and some lakes of egypt. The data obtained in the present work stand as a reference basic record for any future follow up of the contamination level. 1 tab

  2. L'épistémologie et l'histoire des sciences et des techniques peuvent elles aider les futurs enseignants de sciences physiques dans l'exercice de leur métier ? Regards portés pour une ingénierie de formation

    Directory of Open Access Journals (Sweden)

    Guedj Muriel

    2014-01-01

    Full Text Available Cette étude interroge la place de l'Epistémologie, l'Histoire des Sciences et des Techniques comme élément pertinent pour améliorer la professionnalité des enseignants de sciences physiques. La réflexion se nourrit des nouvelles orientations prises au sein d'écoles d'ingénieurs et de facultés de médecine qui ont fait le choix d'introduire des unités d'enseignement dédiées aux Sciences Humaines et Sociales afin de perfectionner la qualité professionnelle de leurs formations. Une étude de cas dédiée à l'enseignement de l'énergie illustre le propos.

  3. A cost-effective technique for integrating personal radiation dose assessment with personal gravimetric sampling

    International Nuclear Information System (INIS)

    Strydom, R.; Rolle, R.; Van der Linde, A.

    1992-01-01

    During recent years there has been an increasing awareness internationally of radiation levels in the mining and milling of radioactive ores, including those from non-uranium mines. A major aspect of radiation control is concerned with the measurement of radiation levels and the assessment of radiation doses incurred by individual workers. Current techniques available internationally for personnel monitoring of radiation exposures are expensive and there is a particular need to reduce the cost of personal radiation monitoring in South African gold mines because of the large labour force employed. In this regard the obvious benefits of integrating personal radiation monitoring with existing personal monitoring systems already in place in South African gold mines should be exploited. A system which can be utilized for this purpose is personal gravimetric sampling. A new cost-effective technique for personal radiation monitoring, which can be fully integrated with the personal gravimetric sampling strategy being implemented on mines, has been developed in South Africa. The basic principles of this technique and its potential in South African mines are described. 9 refs., 7 figs

  4. Fakinle et al (11)

    African Journals Online (AJOL)

    DELL

    management issues; there is however a concern about air emissions from the ... poses risks to humans and animals through ... Nigeria have focused on cement industries. (Adejumo et al. ... based MCA which controls the sample holder and.

  5. 238U And 232Th Concentration In Rock Samples using Alpha Autoradiography and Gamma Spectroscopy Techniques

    International Nuclear Information System (INIS)

    Hafez, A.F.; El-Farrash, A.H.; Yousef, H.A.

    2009-01-01

    The activity concentrations of uranium and thorium were measured for some rock samples selected from Dahab region in the south tip of Sinai. In order to detect any harmful radiation that would affect on the tourists and is becoming economic resource because Dahab have open fields of tourism in Egypt. The activity concentration of uranium and thorium in rocks samples was measured using two techniques. The first is .-autoradiography technique with LR-115 and CR-39 detectors and the second is gamma spectroscopic technique with NaI(Tl) detector. It was found that the average activity concentrations of uranium and thorium using .-autoradiography technique ranged from 6.41-49.31 Bqkg-1, 4.86- 40.87 Bqkg-1 respectively and by gamma detector are ranged from 6.70- 49.50 Bqkg-1, 4.47- 42.33 Bqkg-1 respectively. From the obtained data we can conclude that there is no radioactive healthy hazard for human and living beings in the area under investigation. It was found that there are no big differences between the calculated thorium to uranium ratios in both techniques

  6. Données probantes empiriques et promotion du leadership en ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Le projet générera de nouvelles preuves et renforcera les capacités locales afin d'utiliser des techniques de pointe pour évaluer les programmes ciblant les groupes les plus vulnérables, y compris les femmes et les adolescentes, les travailleurs migrants et les personnes extrêmement pauvres (celles qui subsistent avec ...

  7. Atmospheric pressure surface sampling/ionization techniques for direct coupling of planar separations with mass spectrometry.

    Science.gov (United States)

    Pasilis, Sofie P; Van Berkel, Gary J

    2010-06-18

    Planar separations, which include thin layer chromatography and gel electrophoresis, are in widespread use as important and powerful tools for conducting separations of complex mixtures. To increase the utility of planar separations, new methods are needed that allow in situ characterization of the individual components of the separated mixtures. A large number of atmospheric pressure surface sampling and ionization techniques for use with mass spectrometry have emerged in the past several years, and several have been investigated as a means for mass spectrometric read-out of planar separations. In this article, we review the atmospheric pressure surface sampling and ionization techniques that have been used for the read-out of planar separation media. For each technique, we briefly explain the operational basics and discuss the analyte type for which it is appropriate and some specific applications from the literature. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  8. Uranium Ore and Concentrate Sampling; Echantillonnage des Minerais et des Concentres d'Uranium; Otbor prob uranovoj rudy i kontsentratov; Muestreo de Minerales y Concentrados de Uranio

    Energy Technology Data Exchange (ETDEWEB)

    McGinley, F. E.; Brown, D. L.; Langridge, R. W. [United States Atomic Energy Commission, Grand Junction, CO (United States)

    1966-02-15

    The Grand Junction Office of the United States Atomic Energy Commission has been responsible for procuring large quantities of natural uranium in both ores and concentrates. The techniques used for sampling ores are necessarily different from those used for concentrates. Each step in the overall measurement and sampling systems for both ores and concentrates is discussed, giving particular attention to the accuracy and precision of that step. During the years 1948-1964, a total of 58 million tons of ore was sampled in about 40 different mechanical sampling plants in the western United States. All plants have been required to weigh, sample and analyse ore in accordance with practices satisfactory to the USAEC. The ordinary principles of ore sampling, as used for years in the mining industry, have been followed. However, sufficient check sampling and other tests were performed to ensure that the uranium content of the variety of ores sampled was as accurately determined as economically feasible. Concentrates containing about 129 000 t of U{sub 3}O{sub 8} were purchased from domestic producers during the last 17 years. This uranium was contained in approximately 10 000 lots, each of which was weighed, sampled, and analysed in accordance with carefully controlled procedures. These lots were received at USAEC-owned sampling facilities at Grand Junction or Weldon Spring, Missouri, both of which are contractor operated. The average lot consists of about 50 drums (55-gallon size) and weighs approximately 35 000 lb. Because concentrate varies so much in both physical and chemical characteristics, it is necessary to sample each drum. Through the years, various sampling systems were used, such as pipes, open auger, enclosed augers, and falling stream sampling. Falling stream sampling is the most accurate, provided precautions are taken to prevent changes in weight due to exposure to the atmosphere. Because of the tendency of concentrates to sorb or desorb moisture, depending

  9. Waste minimization in analytical chemistry through innovative sample preparation techniques

    International Nuclear Information System (INIS)

    Smith, L. L.

    1998-01-01

    water samples. In this SPME technique, a fused-silica fiber coated with a polymeric film is exposed to the sample, extraction is allowed to take place, and then the analytes are thermally desorbed for GC analysis. Unlike liquid-liquid extraction or solid-phase extraction, SPME consumes all of the extracted sample in the analysis, significantly reducing the required sample volume

  10. High-throughput droplet analysis and multiplex DNA detection in the microfluidic platform equipped with a robust sample-introduction technique

    International Nuclear Information System (INIS)

    Chen, Jinyang; Ji, Xinghu; He, Zhike

    2015-01-01

    In this work, a simple, flexible and low-cost sample-introduction technique was developed and integrated with droplet platform. The sample-introduction strategy was realized based on connecting the components of positive pressure input device, sample container and microfluidic chip through the tygon tubing with homemade polydimethylsiloxane (PDMS) adaptor, so the sample was delivered into the microchip from the sample container under the driving of positive pressure. This sample-introduction technique is so robust and compatible that could be integrated with T-junction, flow-focus or valve-assisted droplet microchips. By choosing the PDMS adaptor with proper dimension, the microchip could be flexibly equipped with various types of familiar sample containers, makes the sampling more straightforward without trivial sample transfer or loading. And the convenient sample changing was easily achieved by positioning the adaptor from one sample container to another. Benefiting from the proposed technique, the time-dependent concentration gradient was generated and applied for quantum dot (QD)-based fluorescence barcoding within droplet chip. High-throughput droplet screening was preliminarily demonstrated through the investigation of the quenching efficiency of ruthenium complex to the fluorescence of QD. More importantly, multiplex DNA assay was successfully carried out in the integrated system, which shows the practicability and potentials in high-throughput biosensing. - Highlights: • A simple, robust and low-cost sample-introduction technique was developed. • Convenient and flexible sample changing was achieved in microfluidic system. • Novel strategy of concentration gradient generation was presented for barcoding. • High-throughput droplet screening could be realized in the integrated platform. • Multiplex DNA assay was successfully carried out in the droplet platform

  11. High-throughput droplet analysis and multiplex DNA detection in the microfluidic platform equipped with a robust sample-introduction technique

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jinyang; Ji, Xinghu [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); He, Zhike, E-mail: zhkhe@whu.edu.cn [Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072 (China); Suzhou Institute of Wuhan University, Suzhou 215123 (China)

    2015-08-12

    In this work, a simple, flexible and low-cost sample-introduction technique was developed and integrated with droplet platform. The sample-introduction strategy was realized based on connecting the components of positive pressure input device, sample container and microfluidic chip through the tygon tubing with homemade polydimethylsiloxane (PDMS) adaptor, so the sample was delivered into the microchip from the sample container under the driving of positive pressure. This sample-introduction technique is so robust and compatible that could be integrated with T-junction, flow-focus or valve-assisted droplet microchips. By choosing the PDMS adaptor with proper dimension, the microchip could be flexibly equipped with various types of familiar sample containers, makes the sampling more straightforward without trivial sample transfer or loading. And the convenient sample changing was easily achieved by positioning the adaptor from one sample container to another. Benefiting from the proposed technique, the time-dependent concentration gradient was generated and applied for quantum dot (QD)-based fluorescence barcoding within droplet chip. High-throughput droplet screening was preliminarily demonstrated through the investigation of the quenching efficiency of ruthenium complex to the fluorescence of QD. More importantly, multiplex DNA assay was successfully carried out in the integrated system, which shows the practicability and potentials in high-throughput biosensing. - Highlights: • A simple, robust and low-cost sample-introduction technique was developed. • Convenient and flexible sample changing was achieved in microfluidic system. • Novel strategy of concentration gradient generation was presented for barcoding. • High-throughput droplet screening could be realized in the integrated platform. • Multiplex DNA assay was successfully carried out in the droplet platform.

  12. The novel programmable riometer for in-depth ionospheric and magnetospheric observations (PRIAMOS) using direct sampling DSP techniques

    OpenAIRE

    Dekoulis, G.; Honary, F.

    2005-01-01

    This paper describes the feasibility study and simulation results for the unique multi-frequency, multi-bandwidth, Programmable Riometer for in-depth Ionospheric And Magnetospheric ObservationS (PRIAMOS) based on direct sampling digital signal processing (DSP) techniques. This novel architecture is based on sampling the cosmic noise wavefront at the antenna. It eliminates the usage of any intermediate frequency (IF) mixer stages (-6 dB) and the noise balancing technique (-3 dB), providing a m...

  13. Laser-Assisted Sampling Techniques in Combination with ICP-MS: A Novel Approach for Particle Analysis at the IAEA Environmental Samples Laboratory

    International Nuclear Information System (INIS)

    Dzigal, N.; Chinea-Cano, E.

    2015-01-01

    Researchers have found many applications for lasers. About two decades ago, scientists started using lasers as sample introduction instruments for mass spectrometry measurements. Similarly, lasers as micro-dissection tools have also been increasingly on demand in the fields of life sciences, materials science, forensics, etc. This presentation deals with the interception of these aforementioned laser-assisted techniques to the field of particle analysis. Historically, the use of a nanosecond laser to ablate material has been used in materials science. Recently, it has been proven that in the analysis of particulate materials the disadvantages associated with the utilization of nanosecond lasers such as overheating and melting of the sample are suppressed when using femtosecond lasers. Further, due to the length of a single laser shot, fs-LA allows a more controlled ablation to occur and therefore the sample plasma is more homogeneous and less mass-fractionation events are detected. The use of laser micro-dissection devices enables the physical segmentation of microsized artefacts previously performed by a laborious manual procedure. By combining the precision of the laser cutting inherent to the LMD technique together with a particle identification methodology, one can increase the efficiency of single particle isolation. Further, besides the increase in throughput of analyses, this combination enhances the signal-to-noise ratio by removing matrix particles effectively. Specifically, this contribution describes the use of an Olympus+MMI laser microdissection device in improving the sample preparation of environmental swipe samples and the installation of an Applied Spectra J200 fs-LA/LIBS (laser ablation/laser inducedbreakdown spectroscopy) system as a sample introduction device to a quadrupole mass spectrometer, the iCap Q from Thermofisher Scientific at the IAEA Environmental Samples Laboratory are explored. Preliminary results of the ongoing efforts for the

  14. Thermophilic Campylobacter spp. in turkey samples: evaluation of two automated enzyme immunoassays and conventional microbiological techniques

    DEFF Research Database (Denmark)

    Borck, Birgitte; Stryhn, H.; Ersboll, A.K.

    2002-01-01

    Aims: To determine the sensitivity and specificity of two automated enzyme immunoassays (EIA), EiaFoss and Minividas, and a conventional microbiological culture technique for detecting thermophilic Campylobacter spp. in turkey samples. Methods and Results: A total of 286 samples (faecal, meat...

  15. Exploring Earth's Atmospheric Biology using a Platform-Extensible Sampling Payload

    Science.gov (United States)

    Gentry, D.; Rothschild, L.

    2012-12-01

    The interactions between Earth's atmosphere and its biosphere, or aerobiology, remain a significant unknown. What few studies have been done conclusively show that Earth's atmosphere has a rich and dynamic microbial presence[Bowers et al., 2010]; that microbes suspended in air survive over long times (1-2 weeks)[Smith et al., 2010] and travel great distances (>5000 km)[Kellogg and Griffin, 2006]; that some airborne bacteria actively nucleate ice crystals, affecting meteorology[Delort et al., 2010]; and that the presence of microbes in the atmosphere has other planetary-scale effects[Delort et al., 2010]. Basic questions, however, such as the number of microbes present, their activity level and state, the different species present and their variance over time and space, remain largely unquantified. Compounding the significant physical and environmental challenges of reliable aerobiological sampling, collection and analysis of biological samples at altitudes above ~10-20 km has traditionally used ad hoc instrumentation and techniques, yielding primarily qualitative analytical results that lack a common basis for comparison[Bowers et al., 2010]. There is a strong need for broad-basis, repeatable, reliably comparable data about aerobiological basics. We describe here a high-altitude environmental and biological sampling project designed specifically to address these issues. The goal is a robust, reliable, re-usable sampling system, with open reproducibility and adaptability for multiple low-cost flight platforms (including ground-tethered systems, high-altitude balloons, and suborbital sounding rockets); by establishing a common modular payload structure for high-altitude sampling with appeal to a broad user base, we hope to encourage widespread collection of comparable aerobiological data. We are on our third prototype iteration, with demonstrated function of two sample capture modules, a support backbone (tracking, data logging, event response, etc.), a simple ground

  16. Solving mercury (Hg) speciation in soil samples by synchrotron X-ray microspectroscopic techniques.

    Science.gov (United States)

    Terzano, Roberto; Santoro, Anna; Spagnuolo, Matteo; Vekemans, Bart; Medici, Luca; Janssens, Koen; Göttlicher, Jörg; Denecke, Melissa A; Mangold, Stefan; Ruggiero, Pacifico

    2010-08-01

    Direct mercury (Hg) speciation was assessed for soil samples with a Hg concentration ranging from 7 up to 240 mg kg(-1). Hg chemical forms were identified and quantified by sequential extractions and bulk- and micro-analytical techniques exploiting synchrotron generated X-rays. In particular, microspectroscopic techniques such as mu-XRF, mu-XRD and mu-XANES were necessary to solve bulk Hg speciation, in both soil fractions soil samples were metacinnabar (beta-HgS), cinnabar (alpha-HgS), corderoite (Hg(3)S(2)Cl(2)), and an amorphous phase containing Hg bound to chlorine and sulfur. The amount of metacinnabar and amorphous phases increased in the fraction soil components was observed. All the observed Hg-species originated from the slow weathering of an inert Hg-containing waste material (K106, U.S. EPA) dumped in the area several years ago, which is changing into a relatively more dangerous source of pollution. Copyright 2010 Elsevier Ltd. All rights reserved.

  17. Le dysfonctionnement socio-spatial des grands ensembles en Algérie: technique de l’analyse wayfinding par méthode “movement traces” et l’analyse morphologique (syntaxe spatiale par logiciel “depthmap”

    Directory of Open Access Journals (Sweden)

    Amara Hima

    2018-03-01

    Full Text Available Résumé La technique de l’analyse syntaxique de la visibilité (Visibility Graph Analysis – VGA et de l’accessibilité (All Line Analysis – ALA par logiciel “DepthMap©(UCL, Londres” et l’analyse du dysfonctionnement wayfinding par méthode “movement traces”, sont utilisées dans ce papier afin de développer un modèle d’analyse et d’investigation de l’impact des changements spatiaux sur le dysfonctionnement socio-spatial du wayfinding, ainsi sur la reproduction urbaine, notamment les transformations des façades et l’appropriation des espaces extérieurs dans les grands ensembles en Algérie. Nous donnons ici le cas d’étude de la cité 1000 logt-Biskra et la cité 500 logt-M’sila. Afin de vérifier cette hypothèse, un modèle d’analyse hybride a été développé par croisement des résultats d’analyses des deux techniques. Par conséquent, le schéma de l’interférence montre que la majorité des piétons préfèrent parcourir les axes courts et droits — caractérisés par une forte propriété syntaxique de visibilité et d’accessibilité (l’intégration, la connectivité et l’intelligibilité — en directions des équipements adjacents et aux milieux des deux cités. Ces itinéraires ont un impact sur les transformations des façades et l’appropriation des espaces extérieurs. Le modèle développé promet de futures recherches sur le plan de la quantification, la modélisation et la simulation du processus de la reproduction urbaine, notamment par les automates cellulaires.

  18. Improvement on Exoplanet Detection Methods and Analysis via Gaussian Process Fitting Techniques

    Science.gov (United States)

    Van Ross, Bryce; Teske, Johanna

    2018-01-01

    Planetary signals in radial velocity (RV) data are often accompanied by signals coming solely from stellar photo- or chromospheric variation. Such variation can reduce the precision of planet detection and mass measurements, and cause misidentification of planetary signals. Recently, several authors have demonstrated the utility of Gaussian Process (GP) regression for disentangling planetary signals in RV observations (Aigrain et al. 2012; Angus et al. 2017; Czekala et al. 2017; Faria et al. 2016; Gregory 2015; Haywood et al. 2014; Rajpaul et al. 2015; Foreman-Mackey et al. 2017). GP models the covariance of multivariate data to make predictions about likely underlying trends in the data, which can be applied to regions where there are no existing observations. The potency of GP has been used to infer stellar rotation periods; to model and disentangle time series spectra; and to determine physical aspects, populations, and detection of exoplanets, among other astrophysical applications. Here, we implement similar analysis techniques to times series of the Ca-2 H and K activity indicator measured simultaneously with RVs in a small sample of stars from the large Keck/HIRES RV planet search program. Our goal is to characterize the pattern(s) of non-planetary variation to be able to know what is/ is not a planetary signal. We investigated ten different GP kernels and their respective hyperparameters to determine the optimal combination (e.g., the lowest Bayesian Information Criterion value) in each stellar data set. To assess the hyperparameters’ error, we sampled their posterior distributions using Markov chain Monte Carlo (MCMC) analysis on the optimized kernels. Our results demonstrate how GP analysis of stellar activity indicators alone can contribute to exoplanet detection in RV data, and highlight the challenges in applying GP analysis to relatively small, irregularly sampled time series.

  19. Coherent optical adaptive technique improves the spatial resolution of STED microscopy in thick samples

    Science.gov (United States)

    Yan, Wei; Yang, Yanlong; Tan, Yu; Chen, Xun; Li, Yang; Qu, Junle; Ye, Tong

    2018-01-01

    Stimulated emission depletion microscopy (STED) is one of far-field optical microscopy techniques that can provide sub-diffraction spatial resolution. The spatial resolution of the STED microscopy is determined by the specially engineered beam profile of the depletion beam and its power. However, the beam profile of the depletion beam may be distorted due to aberrations of optical systems and inhomogeneity of specimens’ optical properties, resulting in a compromised spatial resolution. The situation gets deteriorated when thick samples are imaged. In the worst case, the sever distortion of the depletion beam profile may cause complete loss of the super resolution effect no matter how much depletion power is applied to specimens. Previously several adaptive optics approaches have been explored to compensate aberrations of systems and specimens. However, it is hard to correct the complicated high-order optical aberrations of specimens. In this report, we demonstrate that the complicated distorted wavefront from a thick phantom sample can be measured by using the coherent optical adaptive technique (COAT). The full correction can effectively maintain and improve the spatial resolution in imaging thick samples. PMID:29400356

  20. Abundant spontaneous VLFE activities in Cascadia during ETS and inter-ETS time periods

    Science.gov (United States)

    Ghosh, A.; Hutchison, A. A.; Hawthorne, J.

    2017-12-01

    Very low frequency earthquakes (VLFEs) are discrete seismic events associated with episodic tremor and slip (ETS) events. They are rich in 20-50s energy and depleted in higher frequencies compared to regular local earthquakes of similar magnitudes. VLFEs can be as large as Mw 4.0, and potentially release much more seismic moment than the tremor/LFE activities, making them a critical event determining stress evolution during slow earthquakes [Ghosh et al., 2015]. Their underlying physics and relationship with tremor/LFE, however, are still unclear. In Cascadia, the majority of the VLFEs found so far are clustered near the areas of high geodetic slip during ETS events [Ghosh et al., 2015; Hutchison and Ghosh, 2016]. Interestingly, we found VLFE activity has its own dynamics and can occur independent of tremor/LFE activity. For example, during the 2014 ETS event in northern Cascadia, VLFEs are found to be asynchronous with tremor activity, both in space and time [Hutchison and Ghosh, 2016]. We use a matched filter technique to detect thousands of VLFEs over an ETS-cycle, and perhaps more interestingly, even between ETS events. VLFE activities peak during ETS events, but significant VLFE activity is detected during the inter-ETS time period. Analyses of strainmeter data near the VLFE locations suggest statistically significant strain rate increases during VLFE time periods compared to the background. We suggest that VLFE is a distinct type of seismic radiation different from tremor/LFE, and can operate independently from tremor activities. This is in contrast to a model suggesting that VLFE signals may be a result of many LFE signals arriving at seismic stations in a short time period [Gomberg et al., 2016]. We are making a consistent catalog of VLFE in Cascadia for longer time period. Systematic study of VLFEs is going to provide new insights into the mechanism of slow earthquakes and its relationship with tremor/LFE and slow slip.

  1. ynthèse et caractérisation de MOFs dérivés d’Al (III) et Fe (III) benzendicarboxylate

    OpenAIRE

    MOULAY MELIANI, AMINA

    2015-01-01

    Ce travail interdisciplinaire nous a permis de maitriser les techniques de synthèse des MOFs en général, et l’exploitation des spectres des différentes technique d’analyse spectrale comme : l’infrarouge (IR) et diffraction des Rayon X (DRX) en particulier. Il est important de souligner l’apport original de ce travail qui consiste en la possibilité de l’élaboration de composés purs à partir de réactifs non purifiés, alors qu’il est connu que pour la synthèse de MOFs, il est indispensable d’...

  2. Multiple sensitive estimation and optimal sample size allocation in the item sum technique.

    Science.gov (United States)

    Perri, Pier Francesco; Rueda García, María Del Mar; Cobo Rodríguez, Beatriz

    2018-01-01

    For surveys of sensitive issues in life sciences, statistical procedures can be used to reduce nonresponse and social desirability response bias. Both of these phenomena provoke nonsampling errors that are difficult to deal with and can seriously flaw the validity of the analyses. The item sum technique (IST) is a very recent indirect questioning method derived from the item count technique that seeks to procure more reliable responses on quantitative items than direct questioning while preserving respondents' anonymity. This article addresses two important questions concerning the IST: (i) its implementation when two or more sensitive variables are investigated and efficient estimates of their unknown population means are required; (ii) the determination of the optimal sample size to achieve minimum variance estimates. These aspects are of great relevance for survey practitioners engaged in sensitive research and, to the best of our knowledge, were not studied so far. In this article, theoretical results for multiple estimation and optimal allocation are obtained under a generic sampling design and then particularized to simple random sampling and stratified sampling designs. Theoretical considerations are integrated with a number of simulation studies based on data from two real surveys and conducted to ascertain the efficiency gain derived from optimal allocation in different situations. One of the surveys concerns cannabis consumption among university students. Our findings highlight some methodological advances that can be obtained in life sciences IST surveys when optimal allocation is achieved. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Impacts socio-economiques et environnementaux de la chasse ...

    African Journals Online (AJOL)

    L'objectif de cette étude est d'identifier les impacts socio-économiques et environnementaux de la chasse traditionnelle dans la Région Centrale au Togo. Pour atteindre cet objectif, une combinaison de techniques touchant les dimensions quantitatives et qualitatives a été adoptée. Il se résume à la recherche documentaire ...

  4. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K. [Oulu Univ. (Finland)

    1998-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  5. Sampling and sample preparation development for analytical and on-line measurement techniques of process liquids; Naeytteenoton ja kaesittelyn kehittaeminen prosessinesteiden analytiikan ja on-line mittaustekniikan tarpeisiin - MPKT 11

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, K [Oulu Univ. (Finland)

    1999-12-31

    Main goal of the research project is to develop sampling and sample handling methods and techniques for pulp and paper industry to be used for analysis and on-line purposes. The research focus specially on the research and development of the classification and separation methods and techniques needed for liquid and colloidal substances as well as in ion analysis. (orig.)

  6. Water stable isotope measurements of Antarctic samples by means of IRMS and WS-CRDS techniques

    Science.gov (United States)

    Michelini, Marzia; Bonazza, Mattia; Braida, Martina; Flora, Onelio; Dreossi, Giuliano; Stenni, Barbara

    2010-05-01

    In the last years in the scientific community there has been an increasing interest for the application of stable isotope techniques to several environmental problems such as drinking water safeguarding, groundwater management, climate change, soils and paleoclimate studies etc. For example, the water stable isotopes, being natural tracers of the hydrological cycle, have been extensively used as tools to characterize regional aquifers and to reconstruct past temperature changes from polar ice cores. Here the need for improvements in analytical techniques: the high request for information calls for technologies that can offer a great quantity of analyses in short times and with low costs. Furthermore, sometimes it is difficult to obtain big amount of samples (as is the case for Antarctic ice cores or interstitial water) preventing the possibility to replicate the analyses. Here, we present oxygen and hydrogen measurements performed on water samples covering a big range of isotopic values (from very negative antarctic precipitation to mid-latitude precipitation values) carried out with both the conventional Isotope Ratio Mass Spectrometry (IRMS) technique and with a new method based on laser absorption techniques, the Wavelenght Scanned Cavity Ringdown Spectroscopy (WS-CRDS). This study is focusing on improving the precision of the measurements carried out with WS-CRDS in order to extensively apply this method to Antarctic ice core paleoclimate studies. The WS-CRDS is a variation of the CRDS developed in 1988 by O'Keef and Deacon. In CRDS a pulse of light goes through a box with high reflective inner surfaces; when there is no sample in the box the light beam doesn't find any obstacle in its path, but the reflectivity of the walls is not perfect so eventually there will be an absorption of the light beam; when the sample is injected in the box there is absorption and the difference between the time of absorption without and with sample is proportional to the quantity

  7. Ecrire et s'écrire en prison

    OpenAIRE

    Lionel Rebout

    2010-01-01

    Dans cette contribution, j’entendrai l’écriture de soi au sens de la subjectivité, c’est-à-dire un rapport à soi nécessairement recomposé et remis en cause dans le champ carcéral, cadre décontenançant par la force des choses et source d’une souffrance originale dans la vie d’un homme. Et j’entendrai l’écriture de soi dans ses rapports à l’écriture en tant que technique, pratique de l’intime pour approcher, saisir, questionner l’autre écriture, celle de soi. Ainsi j’interrogerai la prison lors...

  8. Convergence and Efficiency of Adaptive Importance Sampling Techniques with Partial Biasing

    Science.gov (United States)

    Fort, G.; Jourdain, B.; Lelièvre, T.; Stoltz, G.

    2018-04-01

    We propose a new Monte Carlo method to efficiently sample a multimodal distribution (known up to a normalization constant). We consider a generalization of the discrete-time Self Healing Umbrella Sampling method, which can also be seen as a generalization of well-tempered metadynamics. The dynamics is based on an adaptive importance technique. The importance function relies on the weights (namely the relative probabilities) of disjoint sets which form a partition of the space. These weights are unknown but are learnt on the fly yielding an adaptive algorithm. In the context of computational statistical physics, the logarithm of these weights is, up to an additive constant, the free-energy, and the discrete valued function defining the partition is called the collective variable. The algorithm falls into the general class of Wang-Landau type methods, and is a generalization of the original Self Healing Umbrella Sampling method in two ways: (i) the updating strategy leads to a larger penalization strength of already visited sets in order to escape more quickly from metastable states, and (ii) the target distribution is biased using only a fraction of the free-energy, in order to increase the effective sample size and reduce the variance of importance sampling estimators. We prove the convergence of the algorithm and analyze numerically its efficiency on a toy example.

  9. Modification in the assembly technique of histological sections for analysis of spatial distribution of boron by autoradiography

    International Nuclear Information System (INIS)

    Portu, A; Carpano, M; Dagrosa, A; Pozzi, E; Thorp, S; Curotto, P; Cabrini, R L; Saint Martin, G

    2012-01-01

    The Boron Neutron Capture Therapy (BNCT) is a modality for the treatment of cancer, based on the capture reaction 10 B(n,α) 7 Li. The emitted particles are highly transferred linear of energy and have a short range in tissue (10 μ). Therefore, if the boron is selectively accumulates in tumor cellulo, the damage will be limited to preserving normal cellulo. Thus, the knowledge of the location of 10 B in the different structures of biological tissues as tumor and surrounding tissue, is essential when considering BNCT treatment (Barth et al., 2005). Neutron autoradiography is one of the few methods that allow studying the distribution spatial of elements emitters in a material containing such. As part of BNCT, the first step in performing autoradiography involves placing a freeze tissue section on a nuclear track detector (SSNTD) (Wittig et al., 2008). For this purpose, tissue samples are fixed in N 2 (liq) when they are resected after infusion boronated compound. The sample-detector arrangement is irradiated with thermal neutrons and elements cast in the capture reaction zones produce latent damage SSNTD. Chemically attacking the detector, this latent trace level can be amplified by optical microscopy. Thus, the distribution of 10 B in biological samples can be evaluated, so that this technique is suitable for studying the uptake of boron compounds for the different histological structures. In our laboratory, we have developed neutron autoradiography and has been applied to the study of different biological models (Portu et al., 2011a). In particular, the study conducted by the micro-distribution 10 B in tumors from nude mice model of cutaneous melanomas injected with boronophenylalanine (BPA) (Carpano et al, 2010;. Portu et al, 2011b.). Still using means of support for the sample to be cut, as OCTTM, the lack of structure of necrotic areas of tumors such causes tearing of these regions in the cutting process, which prevents achieving adequate for analysis sections

  10. Estimation of trace levels of plutonium in urine samples by fission track technique

    International Nuclear Information System (INIS)

    Sawant, P.D.; Prabhu, S.; Pendharkar, K.A.; Kalsi, P.C.

    2009-01-01

    Individual monitoring of radiation workers handling Pu in various nuclear installations requires the detection of trace levels of plutonium in bioassay samples. It is necessary to develop methods that can detect urinary excretion of Pu in fraction of mBq range. Therefore, a sensitive method such as fission track analysis has been developed for the measurement of trace levels of Pu in bioassay samples. In this technique, chemically separated plutonium from the sample and a Pu standard were electrodeposited on planchettes and covered with Lexan solid state nuclear track detector (SSNTD) and irradiated with thermal neutrons in APSARA reactor of Bhabha Atomic Research Centre, India. The fission track densities in the Lexan films of the sample and the standard were used to calculate the amount of Pu in the sample. The minimum amount of Pu that can be analyzed by this method using doubly distilled electronic grade (E. G.) reagents is about 12 μBq/L. (author)

  11. Fabrication Techniques of Stretchable and Cloth Electroadhesion Samples for Implementation on Devices with Space Application

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of this study is to determine materials and fabrication techniques for efficient space-rated electroadhesion (EA) samples. Liquid metals, including...

  12. Sciences et société sociologie du travail scientifique

    CERN Document Server

    Vinck, Dominique

    2007-01-01

    Sciences et techniques sont plus que jamais impliquées dans nos grands problèmes de société. Explosion des nanotechnologies, controverse sur les OGM, changement climatique, etc., autant de thématiques dont la compréhension et la maîtrise impliquent aussi de mieux connaître les dynamiques sociales de fabrication de connaissances et des innovations. Le présent ouvrage, refonte complète de la Sociologie des sciences (1995, dans la même collection), relève ce défi. Il présente les différentes formes d'articulation sciences / société (émergence des sciences, dynamique d'innovation, démocratie technique) et les principaux mécanismes sociaux qui font vivre les sciences (institutions, organisations, échanges entre chercheurs, construction des contenus, etc.). Il permet d'appréhender la culture matérielle et cognitive d'un laboratoire comme le fonctionnement des marchés de l'emploi scientifique. Au-delà, en référence aux grands auteurs, courants de pensée et débats, il aide à mieux compre...

  13. Internet et la recomposition territoriale des relations dans l'agriculture suisse

    OpenAIRE

    Gigon, Nathalie; Crevoisier, Olivier

    2015-01-01

    L'agriculture et l'industrie agro-alimentaire suisses se transformed très rapidement. À un monde industrial fonctionnant à l'échelle nationale et basé sur des normes techniques succède un monde domestique basé sur l'identité régionale et les relations interpersonnelles. L'utilisation d'Internet devrait participer à la recomposition des relations entre producteurs et consommateurs et refléter les transformations territoriales qu'elles impliquent. Or les sites Internet de promotion des produits...

  14. A review of analytical techniques for the determination of carbon-14 in environmental samples

    International Nuclear Information System (INIS)

    Milton, G.M.; Brown, R.M.

    1993-11-01

    This report contains a brief summary of analytical techniques commonly used for the determination of radiocarbon in a variety of environmental samples. Details of the applicable procedures developed and tested in the Environmental Research Branch at Chalk River Laboratories are appended

  15. Arsenic, Antimony, Chromium, and Thallium Speciation in Water and Sediment Samples with the LC-ICP-MS Technique

    Directory of Open Access Journals (Sweden)

    Magdalena Jabłońska-Czapla

    2015-01-01

    Full Text Available Chemical speciation is a very important subject in the environmental protection, toxicology, and chemical analytics due to the fact that toxicity, availability, and reactivity of trace elements depend on the chemical forms in which these elements occur. Research on low analyte levels, particularly in complex matrix samples, requires more and more advanced and sophisticated analytical methods and techniques. The latest trends in this field concern the so-called hyphenated techniques. Arsenic, antimony, chromium, and (underestimated thallium attract the closest attention of toxicologists and analysts. The properties of those elements depend on the oxidation state in which they occur. The aim of the following paper is to answer the question why the speciation analytics is so important. The paper also provides numerous examples of the hyphenated technique usage (e.g., the LC-ICP-MS application in the speciation analysis of chromium, antimony, arsenic, or thallium in water and bottom sediment samples. An important issue addressed is the preparation of environmental samples for speciation analysis.

  16. Techniques for the detection of pathogenic Cryptococcus species in wood decay substrata and the evaluation of viability in stored samples

    Directory of Open Access Journals (Sweden)

    Christian Alvarez

    2013-02-01

    Full Text Available In this study, we evaluated several techniques for the detection of the yeast form of Cryptococcus in decaying wood and measured the viability of these fungi in environmental samples stored in the laboratory. Samples were collected from a tree known to be positive for Cryptococcus and were each inoculated on 10 Niger seed agar (NSA plates. The conventional technique (CT yielded a greater number of positive samples and indicated a higher fungal density [in colony forming units per gram of wood (CFU.g-1] compared to the humid swab technique (ST. However, the difference in positive and false negative results between the CT-ST was not significant. The threshold of detection for the CT was 0.05.10³ CFU.g-1, while the threshold for the ST was greater than 0.1.10³ CFU-1. No colonies were recovered using the dry swab technique. We also determined the viability of Cryptococcus in wood samples stored for 45 days at 25ºC using the CT and ST and found that samples not only continued to yield a positive response, but also exhibited an increase in CFU.g-1, suggesting that Cryptococcus is able to grow in stored environmental samples. The ST.1, in which samples collected with swabs were immediately plated on NSA medium, was more efficient and less laborious than either the CT or ST and required approximately 10 min to perform; however, additional studies are needed to validate this technique.

  17. Bilan des flux de matières particulaires et dissoutes du Sassandra à ...

    African Journals Online (AJOL)

    2Centre de Recherches Océanologiques, Rue des pêcheurs, BP V 18 Abidjan – Cote d'Ivoire. *Auteur pour les ... situé entre 5° et 9° 50 de latitude nord, et 6° 50 et ... Il existe de nombreuses techniques de mesures ..... Diagnostic et prévision.

  18. Investigation of CPD and HMDS Sample Preparation Techniques for Cervical Cells in Developing Computer-Aided Screening System Based on FE-SEM/EDX

    Science.gov (United States)

    Ng, Siew Cheok; Abu Osman, Noor Azuan

    2014-01-01

    This paper investigated the effects of critical-point drying (CPD) and hexamethyldisilazane (HMDS) sample preparation techniques for cervical cells on field emission scanning electron microscopy and energy dispersive X-ray (FE-SEM/EDX). We investigated the visualization of cervical cell image and elemental distribution on the cervical cell for two techniques of sample preparation. Using FE-SEM/EDX, the cervical cell images are captured and the cell element compositions are extracted for both sample preparation techniques. Cervical cell image quality, elemental composition, and processing time are considered for comparison of performances. Qualitatively, FE-SEM image based on HMDS preparation technique has better image quality than CPD technique in terms of degree of spread cell on the specimen and morphologic signs of cell deteriorations (i.e., existence of plate and pellet drying artifacts and membrane blebs). Quantitatively, with mapping and line scanning EDX analysis, carbon and oxygen element compositions in HMDS technique were higher than the CPD technique in terms of weight percentages. The HMDS technique has shorter processing time than the CPD technique. The results indicate that FE-SEM imaging, elemental composition, and processing time for sample preparation with the HMDS technique were better than CPD technique for cervical cell preparation technique for developing computer-aided screening system. PMID:25610902

  19. Données préliminaires sur le paludisme humain en zones rurale et ...

    African Journals Online (AJOL)

    SARAH

    31 juil. 2017 ... axée sur le diagnostic précoce et la prise en charge rapide des ... recherche investigue sur les connaissances, attitudes et ... paludisme et (vi) sur la source de traitement du paludisme. ... technique ELISA (Burkot et al., 1984).

  20. Clinical application of microsampling versus conventional sampling techniques in the quantitative bioanalysis of antibiotics: a systematic review.

    Science.gov (United States)

    Guerra Valero, Yarmarly C; Wallis, Steven C; Lipman, Jeffrey; Stove, Christophe; Roberts, Jason A; Parker, Suzanne L

    2018-03-01

    Conventional sampling techniques for clinical pharmacokinetic studies often require the removal of large blood volumes from patients. This can result in a physiological or emotional burden, particularly for neonates or pediatric patients. Antibiotic pharmacokinetic studies are typically performed on healthy adults or general ward patients. These may not account for alterations to a patient's pathophysiology and can lead to suboptimal treatment. Microsampling offers an important opportunity for clinical pharmacokinetic studies in vulnerable patient populations, where smaller sample volumes can be collected. This systematic review provides a description of currently available microsampling techniques and an overview of studies reporting the quantitation and validation of antibiotics using microsampling. A comparison of microsampling to conventional sampling in clinical studies is included.

  1. Elemental analysis of brazing alloy samples by neutron activation technique

    International Nuclear Information System (INIS)

    Eissa, E.A.; Rofail, N.B.; Hassan, A.M.; El-Shershaby, A.; Walley El-Dine, N.

    1996-01-01

    Two brazing alloy samples (C P 2 and C P 3 ) have been investigated by Neutron activation analysis (NAA) technique in order to identify and estimate their constituent elements. The pneumatic irradiation rabbit system (PIRS), installed at the first egyptian research reactor (ETRR-1) was used for short-time irradiation (30 s) with a thermal neutron flux of 1.6 x 10 1 1 n/cm 2 /s in the reactor reflector, where the thermal to epithermal neutron flux ratio is 106. Long-time irradiation (48 hours) was performed at reactor core periphery with thermal neutron flux of 3.34 x 10 1 2 n/cm 2 /s, and thermal to epithermal neutron flux ratio of 79. Activation by epithermal neutrons was taken into account for the (1/v) and resonance neutron absorption in both methods. A hyper pure germanium detection system was used for gamma-ray acquisitions. The concentration values of Al, Cr, Fe, Co, Cu, Zn, Se, Ag and Sb were estimated as percentages of the sample weight and compared with reported values. 1 tab

  2. Elemental analysis of brazing alloy samples by neutron activation technique

    Energy Technology Data Exchange (ETDEWEB)

    Eissa, E A; Rofail, N B; Hassan, A M [Reactor and Neutron physics Department, Nuclear Research Centre, Atomic Energy Authority, Cairo (Egypt); El-Shershaby, A; Walley El-Dine, N [Physics Department, Faculty of Girls, Ain Shams Universty, Cairo (Egypt)

    1997-12-31

    Two brazing alloy samples (C P{sup 2} and C P{sup 3}) have been investigated by Neutron activation analysis (NAA) technique in order to identify and estimate their constituent elements. The pneumatic irradiation rabbit system (PIRS), installed at the first egyptian research reactor (ETRR-1) was used for short-time irradiation (30 s) with a thermal neutron flux of 1.6 x 10{sup 1}1 n/cm{sup 2}/s in the reactor reflector, where the thermal to epithermal neutron flux ratio is 106. Long-time irradiation (48 hours) was performed at reactor core periphery with thermal neutron flux of 3.34 x 10{sup 1}2 n/cm{sup 2}/s, and thermal to epithermal neutron flux ratio of 79. Activation by epithermal neutrons was taken into account for the (1/v) and resonance neutron absorption in both methods. A hyper pure germanium detection system was used for gamma-ray acquisitions. The concentration values of Al, Cr, Fe, Co, Cu, Zn, Se, Ag and Sb were estimated as percentages of the sample weight and compared with reported values. 1 tab.

  3. Agent des projets et des partenariats (h/f) | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Gestion de projets. L'agent(e) : fournit un encadrement technique, notamment en analysant les rapports d'étape, en participant à des ateliers, en effectuant des recherches ... travaille et contribue à l'élaboration du plan de travail de la Division et du portefeuille de projets en découlant, au sein de la structure de la DPDA; et.

  4. Trace uranium analysis in geological sample by isotope dilution-alpha spectrometry and comparison with other techniques

    International Nuclear Information System (INIS)

    Shihomatsu, H.M.; Iyer, S.S.

    1988-12-01

    Establishment of uranium determination in geological samples by alpha spectrometric isotope dilution technique using 233 U tracer is described in the present work. The various steps involved in the method namely, preparation of the sample, electrodeposition, alpha spectrometry, isotope dilution, calculation of the concentration and error statistics are discussed in detail. The experimental parameters for the electrodeposition of uranium, like current density, pH concentration of the electrolyte solution, deposition time, electrode distance were all optimised based on the efficiency of the deposition. The total accuracy and precision of the IDAS using 233 U tracer in the determination of uranium in mineral and granite samples were of the order of 1 to 2% for the concentration range of 50-1500 ppm of U. Our results are compared with those obtained by others workers using similar and different techniques. (author) [pt

  5. Revue d'Information Scientifique et Technique - Vol 10, No 1 (2000)

    African Journals Online (AJOL)

    Le Système Algérien d'Information documentaire agricole: quell appui à la formation et la Recherche Nationales? EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. R Issolah, JF Giovannetti, 109-121. http://dx.doi.org/10.4314/rist.v10i1.26732 ...

  6. Comparison of mobile and stationary spore-sampling techniques for estimating virulence frequencies in aerial barley powdery mildew populations

    DEFF Research Database (Denmark)

    Hovmøller, M.S.; Munk, L.; Østergård, Hanne

    1995-01-01

    Gene frequencies in samples of aerial populations of barley powdery mildew (Erysiphe graminis f.sp. hordei), which were collected in adjacent barley areas and in successive periods of time, were compared using mobile and stationary sampling techniques. Stationary samples were collected from trap ...

  7. Sampling hydrometeors in clouds in-situ - the replicator technique

    Science.gov (United States)

    Wex, Heike; Löffler, Mareike; Griesche, Hannes; Bühl, Johannes; Stratmann, Frank; Schmitt, Carl; Dirksen, Ruud; Reichardt, Jens; Wolf, Veronika; Kuhn, Thomas; Prager, Lutz; Seifert, Patric

    2017-04-01

    For the examination of ice crystals in clouds, concerning their number concentrations, sizes and shapes, often instruments mounted on fast flying aircraft are used. One related disadvantage is possible shattering of the ice crystals on inlets, which has been improved with the introduction of the "Korolev-tip" and by accounting for inter-arrival times (Korolev et al., 2013, 2015), but additionally, the typically fast flying aircraft allow only for a low spatial resolution. Alternative sampling methods have been introduced as e.g., a replicator by Miloshevich & Heymsfield (1997) and an in-situ imager by by Kuhn & Heymsfield (2016). They both sample ice crystals onto an advancing stripe while ascending on a balloon, conserving the ice crystals either in formvar for later off-line analysis under a microscope (Miloshevich & Heymsfield, 1997) or imaging them upon their impaction on silicone oil (Kuhn & Heymsfield, 2016), both yielding vertical profiles for different ice crystal properties. A measurement campaign was performed at the Lindenberg Meteorological Observatory of the German Meteorological Service (DWD) in Germany in October 2016, during which both types of instruments were used during balloon ascents, while ground-based Lidar and cloud-radar measurements were performed simultaneously. The two ice particle sondes were operated by people from the Lulea University of Technology and from TROPOS, where the latter one was made operational only recently. Here, we will show first results of the TROPOS replicator on ice crystals sampled during one ascent, for which the collected ice crystals were analyzed off-line using a microscope. Literature: Korolev, A., E. Emery, and K. Creelman (2013), Modification and tests of particle probe tips to mitigate effects of ice shattering, J. Atmos. Ocean. Tech., 30, 690-708, 2013. Korolev, A., and P. R. Field (2015), Assessment of the performance of the inter-arrival time algorithm to identify ice shattering artifacts in cloud

  8. Preparation of quality control samples for thyroid hormones T3 and T4 in radioimmunoassay techniques

    International Nuclear Information System (INIS)

    Ahmed, F.O.A.

    2006-03-01

    Today, the radioimmunoassay becomes one of the best techniques for quantitative analysis of very low concentration of different substances. RIA is being widely used in medical and research laboratories. To maintain high specificity and accuracy in RIA and other related techniques the quality controls must be introduced. In this dissertation quality control samples for thyroid hormones (Triiodothyronine T3 and Thyroxin T4), using RIA techniques. Ready made chinese T4, T3 RIA kits were used. IAEA statistical package were selected.(Author)

  9. Theory and technique of spark source mass spectrometry; Theorie et technique de la spectrometrie de masse a etincelles

    Energy Technology Data Exchange (ETDEWEB)

    Stefani, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-07-01

    Trace analysis in solids by spark source mass spectrometry involves complicated phenomena: element ionization in spark and blacking of sensitive emulsion by focused ion beam. However the principal risk of selectivity lies in analyser system, which realizes double focusing only for a part of the ions. Therefore, each analyst has to known ionic optics of his apparatus, for ensuring the transmission of mean energetic ions, which are representative of sample composition. By a careful photometry of mass spectrum, good reproducibility can be obtained. Thereafter accuracy depends on the knowledge of sensitivity coefficients proper to this apparatus. (author) [French] L'analyse de traces dans les solides par spectrometrie de masse a etincelles met en jeu des phenomenes complexes qui sont l'ionisation des elements dans l'etincelle, et le noircissement de l'emulsion sensible par les faisceaux ioniques focalises. Cependant, le risque majeur de selectivite provient de l'ensemble analyseur, qui realise la double focalisation sur une fraction seulement du faisceau d'ions. L'analyste doit donc connaitre en detail l'optique ionique de son appareil, pour assurer le passage de la bande d'energie moyenne des ions, qui seule caracterise quantitativement la composition chimique de l'echantillon. Une exploitation photometrique soignee du spectrogramme donne alors des resultats reproductibles, dont la justesse ne depend plus que des coefficients de sensibilite propres a ce type d'instrument. (auteur)

  10. Improved sample preparation and counting techniques for enhanced tritium measurement sensitivity

    Science.gov (United States)

    Moran, J.; Aalseth, C.; Bailey, V. L.; Mace, E. K.; Overman, C.; Seifert, A.; Wilcox Freeburg, E. D.

    2015-12-01

    Tritium (T) measurements offer insight to a wealth of environmental applications including hydrologic tracking, discerning ocean circulation patterns, and aging ice formations. However, the relatively short half-life of T (12.3 years) limits its effective age dating range. Compounding this limitation is the decrease in atmospheric T content by over two orders of magnitude (from 1000-2000 TU in 1962 to testing in the 1960's. We are developing sample preparation methods coupled to direct counting of T via ultra-low background proportional counters which, when combined, offer improved T measurement sensitivity (~4.5 mmoles of H2 equivalent) and will help expand the application of T age dating to smaller sample sizes linked to persistent environmental questions despite the limitations above. For instance, this approach can be used to T date ~ 2.2 mmoles of CH4 collected from sample-limited systems including microbial communities, soils, or subsurface aquifers and can be combined with radiocarbon dating to distinguish the methane's formation age from C age in a system. This approach can also expand investigations into soil organic C where the improved sensitivity will permit resolution of soil C into more descriptive fractions and provide direct assessments of the stability of specific classes of organic matter in soils environments. We are employing a multiple step sample preparation system whereby organic samples are first combusted with resulting CO2 and H2O being used as a feedstock to synthesize CH4. This CH4 is mixed with Ar and loaded directly into an ultra-low background proportional counter for measurement of T β decay in a shallow underground laboratory. Analysis of water samples requires only the addition of geologic CO2 feedstock with the sample for methane synthesis. The chemical nature of the preparation techniques enable high sample throughput with only the final measurement requiring T decay with total sample analysis time ranging from 2 -5 weeks

  11. Detection of Chlamydophila psittaci from feral pigeons in environmental samples: problems with currently available techniques.

    Science.gov (United States)

    Geigenfeind, Ila; Haag-Wackernagel, Daniel

    2010-03-01

    Chlamydophila psittaci (Lillie, 1930) Everett et al., 1999, the pathogenic agent of human ornithosis, is widespread in feral pigeon populations and many cases of transmission from feral pigeons to humans have been reported. The aim of the present study was to detect C. psittaci in environmental samples to find out more about possible transmission routes and, therefore, to assess the zoonotic risk for humans. Fecal samples were collected from nest boxes in a feral pigeon loft. Additionally, samples were taken from the feather dust film covering the water surface of public fountains where pigeons regularly bathe. The samples were tested for the presence of chlamydial antigen using an antigen enzyme-linked immunosorbent assay to prove shedding of C. psittaci by feral pigeons. This test detects a genus specific lipopolysaccharide in the outer membrane of the chlamydial bacteria. Samples were tested using the IDEIA PCE Chlamydia Test kit (DakoCytomation) and positive results were verified with IDEIA Chlamydia Blocking Reagents (DakoCytomation). The IDEIA PCE Chlamydia Test yields a high proportion of positive results. However, when IDEIA Chlamydia Blocking was performed, most of the positive results turned out to be negative or could not be interpreted. We conclude that antigen-enzyme-linked immunosorbent assay tests are not suitable for detecting C. psittaci in environmental samples. Previous publications where no blocking test was used should be reconsidered critically. © 2010 ISZS, Blackwell Publishing and IOZ/CAS.

  12. Les golems du numérique droit d'auteur et Lex Electronica

    CERN Document Server

    Dulong de Rosnay, Mélanie

    2016-01-01

    Le droit d’auteur, élaboré sur les fondements analogiques de la rareté du support, est remis en question par le numérique, qui s’appuie sur la copie, la réappropriation et le partage. Il a été adapté au rythme des innovations techniques de reproduction et de diffusion et peut conduire aussi bien au contrôle de l’accès qu’à la constitution de biens communs. Les processus d’élaboration des normes et standards techniques et d’extension des droits ont été pensés de manière indépendante, entraînant des tensions entre les industries culturelles et les droits du public. L’ouvrage propose un modèle techno-juridique de la régulation du partage de la culture. Fondé sur la lex informatica, il intègre code juridique et code informatique pour exprimer les informations sur les droits et élargir les catégories actuelles du droit d’auteur pour faciliter l’utilisation, la création et le partage non marchand. Ce livre est basé sur plus de dix ans de participation à la régulat...

  13. Technique of nuclear reactors controls; Technique des controles des reacteurs nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-12-15

    This report deal about 'Techniques of control of the nuclear reactors' in the goal to achieve the control of natural uranium reactors and especially the one of Saclay. This work is mainly about the measurement into nuclear parameters and go further in the measurement of thermodynamic variables,etc... putting in relief the new features required on behalf of the detectors because of their use in the thermal neutrons flux. In the domain of nuclear measurement, we indicate the realizations and the results obtained with thermal neutron detectors and for the measurement of ionizations currents. We also treat the technical problem of the start-up of a reactor and of the reactivity measurement. We give the necessary details for the comprehension of all essential diagrams and plans put on, in particular, for the reactor of Saclay. (author) [French] Nous avons aborde le probleme de la ''Technique du Controle des reacteurs nucleaires'' dans le but de realiser le controle du reacteur de Saclay. C'est ainsi que nous avons ete amene a etudier le probleme dans son ensemble, tel qu'il se pose pour tout reacteur a uranium naturel. Ce travail traite principalement du domaine des mesures a caractere nucleaire et s'etend dans le domaine des mesures thermodynamque de niveaux, etc... mettant en relief les caracteristiques nouvelles exigees de la part des detecteurs du fait de leur utilisation dans le flux de neutrons thermiques. Dans le domaine de mesures nucleaires, nous indiquons principalement les realisations et les resultats obtenus pour les detecteurs de neutrons thermiques et pour la mesure de courants d'ionisations. Nous traitons egalement du probleme technique du demarrage d'un reacteur et du probleme de la mesure de la reactivite. Nous donnons les details necessaires a la comrehension de tous les schemas et plans de cablages essentiels mis au point, en particulier, pour le reacteur de Saclay. (auteur)

  14. Performance evaluation of an importance sampling technique in a Jackson network

    Science.gov (United States)

    brahim Mahdipour, E.; Masoud Rahmani, Amir; Setayeshi, Saeed

    2014-03-01

    Importance sampling is a technique that is commonly used to speed up Monte Carlo simulation of rare events. However, little is known regarding the design of efficient importance sampling algorithms in the context of queueing networks. The standard approach, which simulates the system using an a priori fixed change of measure suggested by large deviation analysis, has been shown to fail in even the simplest network settings. Estimating probabilities associated with rare events has been a topic of great importance in queueing theory, and in applied probability at large. In this article, we analyse the performance of an importance sampling estimator for a rare event probability in a Jackson network. This article carries out strict deadlines to a two-node Jackson network with feedback whose arrival and service rates are modulated by an exogenous finite state Markov process. We have estimated the probability of network blocking for various sets of parameters, and also the probability of missing the deadline of customers for different loads and deadlines. We have finally shown that the probability of total population overflow may be affected by various deadline values, service rates and arrival rates.

  15. Beyond simple small-angle X-ray scattering: developments in online complementary techniques and sample environments.

    Science.gov (United States)

    Bras, Wim; Koizumi, Satoshi; Terrill, Nicholas J

    2014-11-01

    Small- and wide-angle X-ray scattering (SAXS, WAXS) are standard tools in materials research. The simultaneous measurement of SAXS and WAXS data in time-resolved studies has gained popularity due to the complementary information obtained. Furthermore, the combination of these data with non X-ray based techniques, via either simultaneous or independent measurements, has advanced understanding of the driving forces that lead to the structures and morphologies of materials, which in turn give rise to their properties. The simultaneous measurement of different data regimes and types, using either X-rays or neutrons, and the desire to control parameters that initiate and control structural changes have led to greater demands on sample environments. Examples of developments in technique combinations and sample environment design are discussed, together with a brief speculation about promising future developments.

  16. Determination of trace elements in plant samples using XRF, PIXE and ICP-OES techniques

    International Nuclear Information System (INIS)

    Ahmed, Hassan Elzain Hassan

    2014-07-01

    The purpose of this study is to determine trace element concentration (Ca, Cu, Cr, K,Fe, Mn,Sr, and Za) in some sudanese wild plants namely, Ziziphus Abyssinica and Grewia Tenax. X-ray fluorescence ( X RF), particle-induced x-ray emission ( PIXE) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) techniques were used for element determination. A series of plants standard references materials were used to check the reliability of the different employed techniques as well as to estimate possible factors for correcting the concentration of some elements that deviated significantly from their actual concentration. The results showed that, X RF, PIXE and ICP-OES are equally competitive methods for measuring Ca,K, Fe, Sr and Zn elements. Unlikely to ICP-OES seems to be superior techniques tend to be appropriate methods for Cu determination in plant samples however, for Mn element PIXE and ICP-OES are advisable techniques for measuring this element rather than X RF method. On the other hand, ICP-OES seems to be the superior techniques over PIXE and X RF methods for Cr and Ni determination in plant samples. The effect of geographical location on trace elements concentration in plants has been examined through determination of element in different species of Grewia Tenax than collected from different location. Most of measured elements showed similarity indicating there is no significant impact of locations on the difference of element contents. In addition, two plants with different genetic families namely, Ziziphus Spina Christi and Ziziphus Abyssinica were collected from the same location and screened for their trace element content. It was found that there were no difference between the two plants for Ca, K, Cu, Fe, and Sr element. However, significant variations were observed for Mn and Zn concentrations implying the possibility of using of those two elements for plant taxonomy purposes.(Author)

  17. Céramiques et terres cuites architecturales (TCA

    Directory of Open Access Journals (Sweden)

    Jean Rosen

    2003-11-01

    Full Text Available Dans le cadre des nouveaux programmes de l’UMR 5594 mis en place à partir de janvier 2003 pour quatre années, une journée d’informations et d’échanges s’est tenue sur le thème “Céramiques et terres cuites architecturales (TCA”, objets de recherche privilégiés du nouveau thème transversal “Matériaux, techniques et sociétés du Néolithique à l’époque moderne”. Nous avons eu le plaisir d’accueillir pour cette première manifestation 42 personnes, 7 s’étant excusées. - de 10 h à 12 h 30 a eu lieu ...

  18. Production de connaissances, innovation et développement en agriculture et concrétisation du développement durable [Rapport final

    OpenAIRE

    Barbier, Marc

    2006-01-01

    La nécessité d’appuyer le redéploiement des activités scientifiques et techniques pour concrétiser les objectifs d’un Développement Durable est particulièrement marquée pour l’agriculture. Préciser ce que devrait être un tel redéploiement et les conditions susceptibles de le favoriser implique une attention particulière aux régimes de production de connaissances, d’innovation et de développement pour en apprécier les effets quant à la réorientation possible de l’agriculture vers un développem...

  19. Sample application of sensitivity/uncertainty analysis techniques to a groundwater transport problem. National Low-Level Waste Management Program

    International Nuclear Information System (INIS)

    Seitz, R.R.; Rood, A.S.; Harris, G.A.; Maheras, S.J.; Kotecki, M.

    1991-06-01

    The primary objective of this document is to provide sample applications of selected sensitivity and uncertainty analysis techniques within the context of the radiological performance assessment process. These applications were drawn from the companion document Guidelines for Sensitivity and Uncertainty Analyses of Low-Level Radioactive Waste Performance Assessment Computer Codes (S. Maheras and M. Kotecki, DOE/LLW-100, 1990). Three techniques are illustrated in this document: one-factor-at-a-time (OFAT) analysis, fractional factorial design, and Latin hypercube sampling. The report also illustrates the differences in sensitivity and uncertainty analysis at the early and latter stages of the performance assessment process, and potential pitfalls that can be encountered when applying the techniques. The emphasis is on application of the techniques as opposed to the actual results, since the results are hypothetical and are not based on site-specific conditions

  20. Low-mass molecular dynamics simulation: A simple and generic technique to enhance configurational sampling

    Energy Technology Data Exchange (ETDEWEB)

    Pang, Yuan-Ping, E-mail: pang@mayo.edu

    2014-09-26

    Highlights: • Reducing atomic masses by 10-fold vastly improves sampling in MD simulations. • CLN025 folded in 4 of 10 × 0.5-μs MD simulations when masses were reduced by 10-fold. • CLN025 folded as early as 96.2 ns in 1 of the 4 simulations that captured folding. • CLN025 did not fold in 10 × 0.5-μs MD simulations when standard masses were used. • Low-mass MD simulation is a simple and generic sampling enhancement technique. - Abstract: CLN025 is one of the smallest fast-folding proteins. Until now it has not been reported that CLN025 can autonomously fold to its native conformation in a classical, all-atom, and isothermal–isobaric molecular dynamics (MD) simulation. This article reports the autonomous and repeated folding of CLN025 from a fully extended backbone conformation to its native conformation in explicit solvent in multiple 500-ns MD simulations at 277 K and 1 atm with the first folding event occurring as early as 66.1 ns. These simulations were accomplished by using AMBER forcefield derivatives with atomic masses reduced by 10-fold on Apple Mac Pros. By contrast, no folding event was observed when the simulations were repeated using the original AMBER forcefields of FF12SB and FF14SB. The results demonstrate that low-mass MD simulation is a simple and generic technique to enhance configurational sampling. This technique may propel autonomous folding of a wide range of miniature proteins in classical, all-atom, and isothermal–isobaric MD simulations performed on commodity computers—an important step forward in quantitative biology.

  1. Review of cleaning techniques and their effects on the chemical composition of foliar samples

    Energy Technology Data Exchange (ETDEWEB)

    Rossini Oliva, S.; Raitio, H.

    2003-07-01

    Chemical foliar analysis is a tool widely used to study tree nutrition and to monitor the impact and extent of air pollutants. This paper reviews a number of cleaning methods, and the effects of cleaning on foliar chemistry. Cleaning may include mechanical techniques such as the use of dry or moistened tissues, shaking, blowing, and brushing, or use various washing techniques with water or other solvents. Owing to the diversity of plant species, tissue differences, etc., there is no standard procedure for all kinds of samples. Analysis of uncleaned leaves is considered a good method for assessing the degree of air contamination because it provides an estimate of the element content of the deposits on leaf surfaces or when the analysis is aimed at the investigation of transfer of elements along the food chain. Sample cleaning is recommended in order (1) to investigate the transfer rate of chemical elements from soil to plants, (2) to qualify the washoff of dry deposition from foliage and (3) to separate superficially absorbed and biomass-incorporated elements. Since there is not a standard cleaning procedure for all kinds of samples and aims, it is advised to conduct a pilot study in order to be able to establish a cleaning procedure to provide reliable foliar data. (orig.)

  2. Revue d'Information Scientifique et Technique - Vol 9, No 1 (1999)

    African Journals Online (AJOL)

    Conception et réalisation d'un système d'aide à la décision pour la gestion des ressources naturelles · EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. F Admane, A El Maouheb, F Benamara, FZ Djezzar, 11-23. http://dx.doi.org/10.4314/rist.v9i1.26717 ...

  3. Detection of equine herpesvirus in horses with idiopathic keratoconjunctivitis and comparison of three sampling techniques.

    Science.gov (United States)

    Hollingsworth, Steven R; Pusterla, Nicola; Kass, Philip H; Good, Kathryn L; Brault, Stephanie A; Maggs, David J

    2015-09-01

    To determine the role of equine herpesvirus (EHV) in idiopathic keratoconjunctivitis in horses and to determine whether sample collection method affects detection of EHV DNA by quantitative polymerase chain reaction (qPCR). Twelve horses with idiopathic keratoconjunctivitis and six horses without signs of ophthalmic disease. Conjunctival swabs, corneal scrapings, and conjunctival biopsies were collected from 18 horses: 12 clinical cases with idiopathic keratoconjunctivitis and six euthanized controls. In horses with both eyes involved, the samples were taken from the eye judged to be more severely affected. Samples were tested with qPCR for EHV-1, EHV-2, EHV-4, and EHV-5 DNA. Quantity of EHV DNA and viral replicative activity were compared between the two populations and among the different sampling techniques; relative sensitivities of the sampling techniques were determined. Prevalence of EHV DNA as assessed by qPCR did not differ significantly between control horses and those with idiopathic keratoconjunctivitis. Sampling by conjunctival swab was more likely to yield viral DNA as assessed by qPCR than was conjunctival biopsy. EHV-1 and EHV-4 DNA were not detected in either normal or IKC-affected horses; EHV-2 DNA was detected in two of 12 affected horses but not in normal horses. EHV-5 DNA was commonly found in ophthalmically normal horses and horses with idiopathic keratoconjunctivitis. Because EHV-5 DNA was commonly found in control horses and in horses with idiopathic keratoconjunctivitis, qPCR was not useful for the etiological diagnosis of equine keratoconjunctivitis. Conjunctival swabs were significantly better at obtaining viral DNA samples than conjunctival biopsy in horses in which EHV-5 DNA was found. © 2015 American College of Veterinary Ophthalmologists.

  4. Beyond simple small-angle X-ray scattering: developments in online complementary techniques and sample environments

    Directory of Open Access Journals (Sweden)

    Wim Bras

    2014-11-01

    Full Text Available Small- and wide-angle X-ray scattering (SAXS, WAXS are standard tools in materials research. The simultaneous measurement of SAXS and WAXS data in time-resolved studies has gained popularity due to the complementary information obtained. Furthermore, the combination of these data with non X-ray based techniques, via either simultaneous or independent measurements, has advanced understanding of the driving forces that lead to the structures and morphologies of materials, which in turn give rise to their properties. The simultaneous measurement of different data regimes and types, using either X-rays or neutrons, and the desire to control parameters that initiate and control structural changes have led to greater demands on sample environments. Examples of developments in technique combinations and sample environment design are discussed, together with a brief speculation about promising future developments.

  5. Catastrophes et consommation des substances psychoactives

    Directory of Open Access Journals (Sweden)

    Krivokapić Žilijeta

    2009-01-01

    des abus (pilulomanie. Les services d'intervention doivent accorder une attention particulière à la prise de substances psycho­actives. Toute consommation entraîne un risque et toutes les substances, en fonction de la fréquence de leur consommation, ont le potentiel d' engendrer une dépendance. Étant donné que rien ne prouve l'effet bénéfique de la consommation de ces substances, que la consommation soit occasionnelle ou bien au gré des situations, nous croyons que les spécialistes en addictologie doivent faire partie des équipes rattachées aux centres ou services médicaux. Consommer ces substances c' est fuir les problèmes et non pas les affronter. Les stratégies qui aident à faire face aux expériences de vie négatives et à renforcer les capacités de les surmonter seraient, entre autres, la technique d' exposition, la planification de surmonter les difficultés, la sollicitation du soutien social, l' acquisition de la maîtrise de soi, l' acceptation, l' acquisition des techniques de contrôle du stress.

  6. Determination of trace element contents in grass samples for cattle feeding using NAA techniques

    Energy Technology Data Exchange (ETDEWEB)

    Yusof, Alias Mohamad; Jagir Singh, Jasbir Kaur

    1987-09-01

    An investigation on trace elements contents in six types of grass samples used for cattle feeding have been carried out using NAA techniques. The grass samples, Mardi Digit, African Star, Signal, Guinea, Setaria and Setaria Splendida were found to contain at least 19 trace elements in varying concentrations. The results were compared to the figures obtained from available sources to ascertain the status as to whether the grass samples studied would satisfy the minimum requirements of trace elements present in grass for cattle feeding or otherwise. Preference made on the suitability of the grass samples for cattle feeding was based on the availability and abundance of the trace elements, taking into account factors such as the degree of toxicity, inadequate amounts and contamination due to the presence of other trace elements not essential for cattle feeding.

  7. Determination of trace element contents in grass samples for cattle feeding using NAA techniques

    International Nuclear Information System (INIS)

    Alias Mohamad Yusof; Jasbir Kaur Jagir Singh

    1987-01-01

    An investigation on trace elements contents in six types of grass samples used for cattle feeding have been carried out using NAA techniques. The grass samples, Mardi Digit, African Star, Signal, Guinea, Setaria and Setaria Splendida were found to contain at least 19 trace elements in varying concentrations. The results were compared to the figures obtained from available sources to ascertain the status as to whether the grass samples studied would satisfy the minimum requirements of trace elements present in grass for cattle feeding or otherwise. Preference made on the suitability of the grass samples for cattle feeding was based on the availability and abundance of the trace elements, taking into account factors such as the degree of toxicity, inadequate amounts and contamination due to the presence of other trace elements not essential for cattle feeding. (author)

  8. Trace uranium analysis in Indian coal samples using the fission track technique

    International Nuclear Information System (INIS)

    Jojo, P.J.; Rawat, A.; Kumar, Ashavani; Prasad, Rajendra

    1993-01-01

    The ever-growing demand for energy has resulted in the extensive use of fossil fuels, especially coal, for power generation. Coal and its by-products often contain significant amounts of radionuclides, including uranium, which is the ultimate source of the radioactive gas Radon-222. The present study gives the concentration of uranium in coal samples of different collieries in India, collected from various thermal power plants in the state of Uttar Pradesh. The estimates were made using the fission track technique. Latent damage tracks were not found to be uniformly distributed but showed sun bursts and clusters. Non-uniform distributions of trace elements are a very common phenomenon in rocks. The levels of uranium in the coal samples were found to vary from 2.0 to 4.9 ppm in uniform distributions and from 21.3 to 41.0 ppm in non-uniform distributions. Measurements were also made on fly ash samples where the average uranium concentration was found to be 8.4 and 49.3 ppm in uniform and non-uniform distributions, respectively. (author)

  9. Expériences sur les RFQ TRASCO et IPHI et développement du RFQ pour le Linac4

    CERN Document Server

    Mathot, S

    2008-01-01

    Depuis 1999, le CERN est impliqué dans le brasage sous vide des RFQ TRASCO et de IPHI depuis 2002. Pour ces deux projets, les tronçons RFQ sont constitués de 4 pôles indépendants usinés dans du cuivre OFE forgé. Ces pôles ont une longueur comprise entre 1000 et 1200 mm et doivent être assemblés avec une précision de l?ordre de 20 microns. La masse totale d?un tronçon est comprise entre 300 et 450 Kg. La procédure de brasage qui a été proposée et utilisée pour 5 tronçons jusqu'à présent consiste en deux étapes distinctes, l?une horizontale et l?autre verticale. Ce papier décrit ces étapes et les solutions utilisées pour l?alignement des pôles avant brasage. Les problèmes rencontrés, notamment en raison de la relaxation de contraintes lors du cycle thermique de brasage sont discutés. Enfin, les choix techniques retenus pour la fabrication des RFQ pour le projet Linac4 sont présentés.

  10. Single-particle characterization of ice-nucleating particles and ice particles residuals sampled by three different techniques

    Science.gov (United States)

    Kandler, Konrad; Worringen, Annette; Benker, Nathalie; Dirsch, Thomas; Mertes, Stephan; Schenk, Ludwig; Kästner, Udo; Frank, Fabian; Nillius, Björn; Bundke, Ulrich; Rose, Diana; Curtius, Joachim; Kupiszewski, Piotr; Weingartner, Ernest; Vochezer, Paul; Schneider, Johannes; Schmidt, Susan; Weinbruch, Stephan; Ebert, Martin

    2015-04-01

    During January/February 2013, at the High Alpine Research Station Jungfraujoch a measurement campaign was carried out, which was centered on atmospheric ice-nucleating particles (INP) and ice particle residuals (IPR). Three different techniques for separation of INP and IPR from the non-ice-active particles are compared. The Ice Selective Inlet (ISI) and the Ice Counterflow Virtual Impactor (Ice-CVI) sample ice particles from mixed phase clouds and allow for the analysis of the residuals. The combination of the Fast Ice Nucleus Chamber (FINCH) and the Ice Nuclei Pumped Counterflow Virtual Impactor (IN-PCVI) provides ice-activating conditions to aerosol particles and extracts the activated INP for analysis. Collected particles were analyzed by scanning electron microscopy and energy-dispersive X-ray microanalysis to determine size, chemical composition and mixing state. All INP/IPR-separating techniques had considerable abundances (median 20 - 70 %) of instrumental contamination artifacts (ISI: Si-O spheres, probably calibration aerosol; Ice-CVI: Al-O particles; FINCH+IN-PCVI: steel particles). Also, potential sampling artifacts (e.g., pure soluble material) occurred with a median abundance of separated by all three techniques. Soot was a minor contributor. Lead was detected in less than 10 % of the particles, of which the majority were internal mixtures with other particle types. Sea-salt and sulfates were identified by all three methods as INP/IPR. Most samples showed a maximum of the INP/IPR size distribution at 400 nm geometric diameter. In a few cases, a second super-micron maximum was identified. Soot/carbonaceous material and metal oxides were present mainly in the submicron range. ISI and FINCH yielded silicates and Ca-rich particles mainly with diameters above 1 µm, while the Ice-CVI also separated many submicron IPR. As strictly parallel sampling could not be performed, a part of the discrepancies between the different techniques may result from

  11. aboagye et al.2

    African Journals Online (AJOL)

    PUBLICATIONS1

    14 Aboagye et al. wide variety of birds, including chickens, by piercing the quills of feathers and gnawing the epidermis. In doing so, they can spread disease and lower .... evolution. Oikos, 97: 223-228. Nordenfors, H. and Chirico, J. (2001). Evalua- tion of a sampling trap for Dermanyssus gal- linae (Acari: Dermanyssidae).

  12. Effets du travail du sol sur le comportement chimique et biologique ...

    African Journals Online (AJOL)

    SARAH

    31 juil. 2017 ... RESUME. Objectif : L'objectif de cette étude est de comparer les effets de six techniques culturales de mise en place du blé tendre sur certaines propriétés chimiques et biologiques du sol et les conséquences sur le rendement grain et ses composantes dans la région «non chernozem» en 7ème années ...

  13. LVQ-SMOTE - Learning Vector Quantization based Synthetic Minority Over-sampling Technique for biomedical data.

    Science.gov (United States)

    Nakamura, Munehiro; Kajiwara, Yusuke; Otsuka, Atsushi; Kimura, Haruhiko

    2013-10-02

    Over-sampling methods based on Synthetic Minority Over-sampling Technique (SMOTE) have been proposed for classification problems of imbalanced biomedical data. However, the existing over-sampling methods achieve slightly better or sometimes worse result than the simplest SMOTE. In order to improve the effectiveness of SMOTE, this paper presents a novel over-sampling method using codebooks obtained by the learning vector quantization. In general, even when an existing SMOTE applied to a biomedical dataset, its empty feature space is still so huge that most classification algorithms would not perform well on estimating borderlines between classes. To tackle this problem, our over-sampling method generates synthetic samples which occupy more feature space than the other SMOTE algorithms. Briefly saying, our over-sampling method enables to generate useful synthetic samples by referring to actual samples taken from real-world datasets. Experiments on eight real-world imbalanced datasets demonstrate that our proposed over-sampling method performs better than the simplest SMOTE on four of five standard classification algorithms. Moreover, it is seen that the performance of our method increases if the latest SMOTE called MWMOTE is used in our algorithm. Experiments on datasets for β-turn types prediction show some important patterns that have not been seen in previous analyses. The proposed over-sampling method generates useful synthetic samples for the classification of imbalanced biomedical data. Besides, the proposed over-sampling method is basically compatible with basic classification algorithms and the existing over-sampling methods.

  14. Les plantes génétiquement modifiées en Afrique : enjeux et recherches

    Directory of Open Access Journals (Sweden)

    De Lattre-Gasquet Marie

    2002-11-01

    Full Text Available En ce qui concerne la politique sur plantes génétiquement modifiées, l’Afrique est un terrain de luttes d’influence et de débats. Les enjeux sont à la fois économiques, politiques et écologiques. Dans cet article, nous montrons que les biotechnologies végétales sont l’une des techniques, à combiner avec d’autres, qui pourraient permettre d’assurer la sécurité alimentaire et sanitaire de l’Afrique, et que les risques qu’entraîneront l’utilisation de cette technique doivent être soigneusement analysés. Nous présenterons ensuite la position des différents pays africains vis-à-vis des conventions internationales (propriété intellectuelle, biosécurité et commerce et nous caractériserons leurs politiques nationales et de recherche vis-à-vis des OGM.

  15. Extraction of Plutonium From Spiked INEEL Soil Samples Using the Ligand-Assisted Supercritical Fluid Extraction (LA-SFE) Technique

    International Nuclear Information System (INIS)

    Fox, R.V.; Mincher, B.J.; Holmes, R.G.G.

    1999-01-01

    In order to investigate the effectiveness of ligand-assisted supercritical fluid extraction for the removal of transuranic contaminations from soils an Idaho National Engineering and Environmental Laboratory (INEEL) silty-clay soil sample was obtained from near the Radioactive Waste Management Complex area and subjected to three different chemical preparations before being spiked with plutonium. The spiked INEEL soil samples were subjected to a sequential aqueous extraction procedure to determine radionuclide portioning in each sample. Results from those extractions demonstrate that plutonium consistently partitioned into the residual fraction across all three INEEL soil preparations whereas americium partitioned 73% into the iron/manganese fraction for soil preparation A, with the balance partitioning into the residual fraction. Plutonium and americium were extracted from the INEEL soil samples using a ligand-assisted supercritical fluid extraction technique. Initial supercritical fluid extraction runs produced plutonium extraction technique. Initial supercritical fluid extraction runs produced plutonium extraction efficiencies ranging from 14% to 19%. After a second round wherein the initial extraction parameters were changed, the plutonium extraction efficiencies increased to 60% and as high as 80% with the americium level in the post-extracted soil samples dropping near to the detection limits. The third round of experiments are currently underway. These results demonstrate that the ligand-assisted supercritical fluid extraction technique can effectively extract plutonium from the spiked INEEL soil preparations

  16. Présentation Technique - French version only

    CERN Multimedia

    2003-01-01

    Tuesday 9 September PRESENTATION TECHNIQUE From 09:00 - 12:00 - bldg. 40, S2-B01 Techniques de mesure: Acquisition, analyse et présentation avec LabVIEW 7 Express National Instruments Switzerland Avec LabVIEW 7 Express, National Instruments inaugure une nouvelle ère pour la programmation graphique dans le monde de la mesure et de l'automatisation. Pour la première fois dans l'histoire de la programmation par flux de données, les antagonismes inconciliables entre la programmation et la configuration se laissent réduire au même dénominateur et sont disponibles dans un environnement de développement intégré. En outre, cette nouvelle version peut-être supportée par une plus large palette de plates-formes et de matériels cibles : de Windows, Linux ou Mac OS X jusqu'aux PDA (assistants personnels) ou aux FPGA embarqués. Avec LabVIEW 7 Express, vous disposez d'un outil logiciel, qui vous permet de construire encore plus vite, plus facilement et à moindres frais vos...

  17. A novel in-situ sampling and VFA sensor technique for anaerobic systems

    DEFF Research Database (Denmark)

    Pind, Peter Frode; Angelidaki, Irini; Ahring, Birgitte Kiær

    2002-01-01

    A key information for understanding and controlling the anaerobic biogas process is the concentration of Volatile Fatty Acids (VFA). However, access to this information has so far been limited to off-line measurements by manual time and labour consuming methods. We have developed a new technique ...... than 1000 samples on both a fullscale biogas plant and lab-scale reactors. The measuring range covers specific measurements of acetate, propionate, iso-/n-butyrate and iso-/n-valerate from 0.1 to 50 mM (6–3,000 mg)....

  18. Diasporas, transnationalisme et engagement : tamouls et cinghalais ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Diasporas, transnationalisme et engagement : tamouls et cinghalais au Canada et leurs liens avec le Sri Lanka. Ce projet examinera le rôle du financement et des réseaux de la diaspora dans le conflit ethnopolitique au Sri Lanka, en étudiant les réseaux des collectivités transnationales tamoule et cinghalaise au Canada ...

  19. An Electromagnetic Gauge Technique for Measuring Shocked Particle Velocity in Electrically Conductive Samples

    Science.gov (United States)

    Cheng, David; Yoshinaka, Akio

    2014-11-01

    Electromagnetic velocity (EMV) gauges are a class of film gauges which permit the direct in-situ measurement of shocked material flow velocity. The active sensing element, typically a metallic foil, requires exposure to a known external magnetic field in order to produce motional electromotive force (emf). Due to signal distortion caused by mutual inductance between sample and EMV gauge, this technique is typically limited to shock waves in non-conductive materials. In conductive samples, motional emf generated in the EMV gauge has to be extracted from the measured signal which results from the combined effects of both motional emf and voltage changes from induced currents. An electromagnetic technique is presented which analytically models the dynamics of induced current between a copper disk moving as a rigid body with constant 1D translational velocity toward an EMV gauge, where both disk and gauge are exposed to a uniform external static magnetic field. The disk is modelled as a magnetic dipole loop where its Foucault current is evaluated from the characteristics of the fields, whereas the EMV gauge is modelled as a circuit loop immersed in the field of the magnetic dipole loop, the intensity of which is calculated as a function of space and, implicitly, time. Equations of mutual induction are derived and the current induced in the EMV gauge loop is solved, allowing discrimination of the motional emf. Numerical analysis is provided for the step response of the induced EMV gauge current with respect to the Foucault current in the moving copper sample.

  20. Entre l’immersion dans l’image cinématographique et l’immersion totale

    Directory of Open Access Journals (Sweden)

    Marcin Sobieszczanski

    2010-12-01

    Full Text Available Le cinéma organise autour de ses contraintes techniques, relatives à la prise de vue et à l’architecture des salles de projection, une écriture narrative capable de produire un effet à la fois de réel et de fiction, effet qui aspire le spectateur dans un état de suspension et d’abolition de toutes contraintes spatiotemporelles. Mais le genre filmique s’épuise, depuis ses premiers balbutiements et jusqu’à son apogée, entre 1895 et la fin des années 70, évoluant vers une « naturalisation » de l’espace d’acquisition et de visionnement de l’œuvre vidéo-filmique. Les projections splitscreen et multiscreen, et l’écriture scénaristique consécutive à ces techniques, présentent, depuis la fin des années 90, une étape intermédiaire de cette évolution, qui dans un proche avenir, avec différentes déclinaisons et applications de la 3D, s’achemine, en suivant d’ailleurs une tendance anthropologique, vers l’immersion complète ou partielle dans l’image, offrant de surcroit, de nouvelles possibilités d’interaction spectatorielle. Prépare-t-on alors une nouvelle technique narrative ?The cinema organizes around its technical constraints, relative to the recording and to the architecture of projection rooms, a narrative writing capable of producing simultaneousely an effect of both reality and fiction, an effect which puts the spectator in a state of suspension and abolition of all spatiotemporal constraints. But at the same time the cinematic genre has exhausted itself since its beginnings and until its apogee, between 1895 and the end of the 70s, evolving towards a "naturalization" of the space of acquisition and viewing of the video-cinematic work. The projections splitscreen and multiscreen, and the script writing consecutive to these techniques, present, since the end of the 90s, an intermediate stage of this evolution, which will move in the near future, with various declinations and applications of the

  1. L'évaluation et le suivi participatifs

    International Development Research Centre (IDRC) Digital Library (Canada)

    Traduction de: Learning from change: issues and experiences in ...... travaillé avec nous a apporté un soutien technique et moral absolument crucial. ...... and Reporting in Non-profit Organisations », Journal of Business Ethics, vol.17, n° 13, p.

  2. DISTRIBUTION ET ABONDANCE DE SPORES DE CHAMPIGNONS ...

    African Journals Online (AJOL)

    AISA

    (PCR) des racines échantillonnées et le comptage directe des spores des sols échantillonnés ont permis ... cowpea, sing the PCR technique, reveal that this plant was an efficient host for ..... genes from vesicular-arbuscular endomy- ...

  3. Active sampling technique to enhance chemical signature of buried explosives

    Science.gov (United States)

    Lovell, John S.; French, Patrick D.

    2004-09-01

    Deminers and dismounted countermine engineers commonly use metal detectors, ground penetrating radar and probes to locate mines. Many modern landmines have a very low metal content, which severely limits the effectiveness of metal detectors. Canines have also been used for landmine detection for decades. Experiments have shown that canines smell the explosives which are known to leak from most types of landmines. The fact that dogs can detect landmines indicates that vapor sensing is a viable approach to landmine detection. Several groups are currently developing systems to detect landmines by "sniffing" for the ultra-trace explosive vapors above the soil. The amount of material that is available to passive vapor sensing systems is limited to no more than the vapor in equilibrium with the explosive related chemicals (ERCs) distributed in the surface soils over and near the landmine. The low equilibrium vapor pressure of TNT in the soil/atmosphere boundary layer and the limited volume of the boundary layer air imply that passive chemical vapor sensing systems require sensitivities in the picogram range, or lower. ADA is working to overcome many of the limitations of passive sampling methods, by the use of an active sampling method that employs a high-powered (1,200+ joules) strobe lamp to create a highly amplified plume of vapor and/or ERC-bearing fine particulates. Initial investigations have demonstrated that this approach can amplify the detectability of TNT by two or three orders of magnitude. This new active sampling technique could be used with any suitable explosive sensor.

  4. Sampling phased array, a new technique for ultrasonic signal processing and imaging now available to industry

    OpenAIRE

    Verkooijen, J.; Bulavinov, A.

    2008-01-01

    Over the past 10 years the improvement in the field of microelectronics and computer engineering has led to significant advances in ultrasonic signal processing and image construction techniques that are currently being applied to non-destructive material evaluation. A new phased array technique, called "Sampling Phased Array" has been developed in the Fraunhofer Institute for non-destructive testing [1]. It realizes a unique approach of measurement and processing of ultrasonic signals. The s...

  5. Determination of multi-element in marine sediment samples collected in Angola by the k0-NAA technique

    International Nuclear Information System (INIS)

    Teixeira, M.C.P.; Ho Manh Dung; Cao Dong Vu; Nguyen Thi Sy; Nguyen Thanh Binh; Vuong Huu Tan

    2006-01-01

    The marine sediment samples were designed to collect in Angola for marine environmental pollution study. The k 0 -standardization method of neutron activation analysis (k 0 -NAA) on Dalat research reactor has been developed to determine of multi-element in the Angola marine sediment samples. The samples were irradiated in cell 7-1 for short- and middle-lived nuclides and rotary specimen rack for long-lived nuclides. The irradiation facilities were characterized for neutron spectrum parameters and post-activated samples were measured on the calibrated gamma-ray spectrometers using HPGe detectors. The analytical results for 9 marine sediment samples with 27 elements: Al, As, Br, Ca, Ce,Cl, Co, Cs, Dy, Fe, Hf, I, K, Mg, Mn, Na, Rb, Sb, Sc, Se, Sm, Th, Ti, U, V and Zn in term of mean concentration, standard deviation and their content range are shown in the report. The analytical quality assurance was done by analysis of a Japan's certified reference material namely marine sediment NMIJ-CRM-7302a. These preliminary results revealed that the k 0 -NAA technique on the Dalat research reactor is a good analytical technique for determination of multi-element in the marine sediment samples. Some heavy metals and trace elements determined in this work possibly connected to the human activities at the sampling region. (author)

  6. Li et al., Afr J Tradit Complement Altern Med., (2017) 14 (1): 62-72 ...

    African Journals Online (AJOL)

    The aim of the study was to develop a more efficient drug which could not .... The test was carried out using the described technique previously (Zhou et al., 2008). ..... in part by stem cells (Ito et al., 2005, Levy et al., 2005), while hair follicles are ...

  7. Characterization of Some Iraqi Archaeological Samples Using IBA, Analytical X-ray and Other Complementary Techniques

    International Nuclear Information System (INIS)

    Al-Sarraj, Ziyad Shihab; Damboos, Hassan I; Roumie, Mohamad

    2012-01-01

    The present work aimed at investigating the compositions and microstructures of some archaeological samples which dated back to various periods of the ancient Iraqi civilizations using PIXE, XRF, XRD, and SEM techniques. The models selected for the study (ceramics, glaze, etc.) were diverse in size and nature, therefore a limited number of samples were then butted from them by a small diamond wheel. Conventional powder metallurgy method was then used to prepare the samples. Dried samples were then coated with a thin layer of carbon, and analyzed using the ion beam accelerator of the LAEC. Three other groups of samples were also prepared for the purpose of analysis by X-ray fluorescence (XRF), X-ray diffraction (XRD), and scanning electron microscope (SEM). Analysis results of the chemical composition showed good agreement between the various techniques as well as for phases, while the fine structure analysis obtained by optical and scanning microscopy exhibited features of a structure where it got an intensified densification in the final stage of sintering and accompanied by quasi-homogeneous distribution of the closed pores. This will lead to the conclusion that the temperature used for sintering by ancient Iraqi was sufficient and it may fall in the range between 950-1200°C, also the mixes and the forming methods used by them, were both suitable to obtain good sintered bodies with even distribution of pores. A ring-shaped trace noticed in SEM micrographs need more work and study to explain what it is?

  8. Analysis of soil samples from Gebeng area using NAA technique

    Science.gov (United States)

    Elias, Md Suhaimi; Wo, Yii Mei; Hamzah, Mohd Suhaimi; Shukor, Shakirah Abd; Rahman, Shamsiah Ab; Salim, Nazaratul Ashifa Abdullah; Azman, Muhamad Azfar; Hashim, Azian

    2017-01-01

    Rapid development and urbanization will increase number of residence and industrial area. Without proper management and control of pollution, these will give an adverse effect to environment and human life. The objective of this study to identify and quantify key contaminants into the environment of the Gebeng area as a result of industrial and human activities. Gebeng area was gazetted as one of the industrial estate in Pahang state. Assessment of elemental pollution in soil of Gebeng area base on level of concentration, enrichment factor and geo-accumulation index. The enrichment factors (EFs) were determined by the elemental rationing method, whilst the geo-accumulation index (Igeo) by comparing of current to continental crustal average concentration of element. Twenty-seven of soil samples were collected from Gebeng area. Soil samples were analysed by using Neutron Activation Analyses (NAA) technique. The obtained data showed higher concentration of iron (Fe) due to abundance in soil compared to other elements. The results of enrichment factor showed that Gebeng area have enrich with elements of As, Br, Hf, Sb, Th and U. Base on the geo-accumulation index (Igeo) classification, the soil quality of Gebeng area can be classified as class 0, (uncontaminated) to Class 3, (moderately to heavily contaminated).

  9. Advances in modern sample preparation techniques using microwaves assisted chemistry for metal species determination (W1)

    International Nuclear Information System (INIS)

    Ponard, O.F.X.

    2002-01-01

    Full text: Sample preparation has long been the bottleneck of environmental analysis for both total and species specific analysis. Digestion, extraction and preparation of the analytes are relying on a series of chemical reactions. The introduction of microwave assisted sample preparation has first been viewed as a mean to accelerate the kinetics of digestion of the matrix for total elements and fast samples preparation procedures. However, the extensive development and success of microwave digestion procedures in total elemental analysis has now allowed to have a larger insight of the perspectives offered by this technique. Microwave technologies now offer to have a precise control of the temperature and indirectly control the reaction kinetics taking place during the sample preparation procedures. Microwave assisted chemistry permits to perform simultaneously the fundamental steps required for metal species extraction and derivatization. The number of sample preparation steps used for organotin or organomercury species have been reduced to one and the total time of sample preparation brought down for a few hours to some minutes. Further, the developments of GC/ICP/MS techniques allow to routinely use speciated isotopic dilution methods has internal probe of the chemical reactions. These new approaches allow us to use the addition of the labeled species for isotopic dilution as a mean to evaluate and follow the chemical processes taking place during the extraction procedure. These procedures will help us to understand and check for the stability of the analytes during the chemistry of the sample preparation procedure and bring some insights of the chemistry taking place during the extraction. Understanding the different mechanisms involved in the sample preparation steps will allow us in return to further improve all theses procedures and bring us to the horizon of 'on-line sample preparation and detection'. (author)

  10. A comparison of quantitative reconstruction techniques for PIXE-tomography analysis applied to biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Beasley, D.G., E-mail: dgbeasley@ctn.ist.utl.pt [IST/C2TN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Alves, L.C. [IST/C2TN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Barberet, Ph.; Bourret, S.; Devès, G.; Gordillo, N.; Michelet, C. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Le Trequesser, Q. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Institut de Chimie de la Matière Condensée de Bordeaux (ICMCB, UPR9048) CNRS, Université de Bordeaux, 87 avenue du Dr. A. Schweitzer, Pessac F-33608 (France); Marques, A.C. [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Seznec, H. [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Silva, R.C. da [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal)

    2014-07-15

    The tomographic reconstruction of biological specimens requires robust algorithms, able to deal with low density contrast and low element concentrations. At the IST/ITN microprobe facility new GPU-accelerated reconstruction software, JPIXET, has been developed, which can significantly increase the speed of quantitative reconstruction of Proton Induced X-ray Emission Tomography (PIXE-T) data. It has a user-friendly graphical user interface for pre-processing, data analysis and reconstruction of PIXE-T and Scanning Transmission Ion Microscopy Tomography (STIM-T). The reconstruction of PIXE-T data is performed using either an algorithm based on a GPU-accelerated version of the Maximum Likelihood Expectation Maximisation (MLEM) method or a GPU-accelerated version of the Discrete Image Space Reconstruction Algorithm (DISRA) (Sakellariou (2001) [2]). The original DISRA, its accelerated version, and the MLEM algorithm, were compared for the reconstruction of a biological sample of Caenorhabditis elegans – a small worm. This sample was analysed at the microbeam line of the AIFIRA facility of CENBG, Bordeaux. A qualitative PIXE-T reconstruction was obtained using the CENBG software package TomoRebuild (Habchi et al. (2013) [6]). The effects of pre-processing and experimental conditions on the elemental concentrations are discussed.

  11. Lunar Sample Compendium

    Science.gov (United States)

    Meyer, Charles

    2005-01-01

    The purpose of the Lunar Sample Compendium will be to inform scientists, astronauts and the public about the various lunar samples that have been returned from the Moon. This Compendium will be organized rock by rock in the manor of a catalog, but will not be as comprehensive, nor as complete, as the various lunar sample catalogs that are available. Likewise, this Compendium will not duplicate the various excellent books and reviews on the subject of lunar samples (Cadogen 1981, Heiken et al. 1991, Papike et al. 1998, Warren 2003, Eugster 2003). However, it is thought that an online Compendium, such as this, will prove useful to scientists proposing to study individual lunar samples and should help provide backup information for lunar sample displays. This Compendium will allow easy access to the scientific literature by briefly summarizing the significant findings of each rock along with the documentation of where the detailed scientific data are to be found. In general, discussion and interpretation of the results is left to the formal reviews found in the scientific literature. An advantage of this Compendium will be that it can be updated, expanded and corrected as need be.

  12. A cost-saving statistically based screening technique for focused sampling of a lead-contaminated site

    International Nuclear Information System (INIS)

    Moscati, A.F. Jr.; Hediger, E.M.; Rupp, M.J.

    1986-01-01

    High concentrations of lead in soils along an abandoned railroad line prompted a remedial investigation to characterize the extent of contamination across a 7-acre site. Contamination was thought to be spotty across the site reflecting its past use in battery recycling operations at discrete locations. A screening technique was employed to delineate the more highly contaminated areas by testing a statistically determined minimum number of random samples from each of seven discrete site areas. The approach not only quickly identified those site areas which would require more extensive grid sampling, but also provided a statistically defensible basis for excluding other site areas from further consideration, thus saving the cost of additional sample collection and analysis. The reduction in the number of samples collected in ''clean'' areas of the site ranged from 45 to 60%

  13. Techniques de combustion Combustin Techniques

    Directory of Open Access Journals (Sweden)

    Perthuis E.

    2006-11-01

    Full Text Available L'efficacité d'un processus de chauffage par flamme est étroitement liée à la maîtrise des techniques de combustion. Le brûleur, organe essentiel de l'équipement de chauffe, doit d'une part assurer une combustion complète pour utiliser au mieux l'énergie potentielle du combustible et, d'autre part, provoquer dans le foyer les conditions aérodynamiques les plus propices oux transferts de chaleur. En s'appuyant sur les études expérimentales effectuées à la Fondation de Recherches Internationales sur les Flammes (FRIF, au Groupe d'Étude des Flammes de Gaz Naturel (GEFGN et à l'Institut Français du Pétrole (IFP et sur des réalisations industrielles, on présente les propriétés essentielles des flammes de diffusion aux combustibles liquides et gazeux obtenues avec ou sans mise en rotation des fluides, et leurs répercussions sur les transferts thermiques. La recherche des températures de combustion élevées conduit à envisager la marche à excès d'air réduit, le réchauffage de l'air ou son enrichissement à l'oxygène. Par quelques exemples, on évoque l'influence de ces paramètres d'exploitation sur l'économie possible en combustible. The efficiency of a flame heating process is closely linked ta the mastery of, combustion techniques. The burner, an essential element in any heating equipment, must provide complete combustion sa as to make optimum use of the potential energy in the fuel while, at the same time, creating the most suitable conditions for heat transfers in the combustion chamber. On the basis of experimental research performed by FRIF, GEFGN and IFP and of industrial achievements, this article describesthe essential properties of diffusion flames fed by liquid and gaseous fuels and produced with or without fluid swirling, and the effects of such flames on heat transfers. The search for high combustion temperatures means that consideration must be given to operating with reduced excess air, heating the air or

  14. Large Sample Neutron Activation Analysis of Heterogeneous Samples

    International Nuclear Information System (INIS)

    Stamatelatos, I.E.; Vasilopoulou, T.; Tzika, F.

    2018-01-01

    A Large Sample Neutron Activation Analysis (LSNAA) technique was developed for non-destructive analysis of heterogeneous bulk samples. The technique incorporated collimated scanning and combining experimental measurements and Monte Carlo simulations for the identification of inhomogeneities in large volume samples and the correction of their effect on the interpretation of gamma-spectrometry data. Corrections were applied for the effect of neutron self-shielding, gamma-ray attenuation, geometrical factor and heterogeneous activity distribution within the sample. A benchmark experiment was performed to investigate the effect of heterogeneity on the accuracy of LSNAA. Moreover, a ceramic vase was analyzed as a whole demonstrating the feasibility of the technique. The LSNAA results were compared against results obtained by INAA and a satisfactory agreement between the two methods was observed. This study showed that LSNAA is a technique capable to perform accurate non-destructive, multi-elemental compositional analysis of heterogeneous objects. It also revealed the great potential of the technique for the analysis of precious objects and artefacts that need to be preserved intact and cannot be damaged for sampling purposes. (author)

  15. Single-particle characterization of ice-nucleating particles and ice particle residuals sampled by three different techniques

    Science.gov (United States)

    Worringen, A.; Kandler, K.; Benker, N.; Dirsch, T.; Mertes, S.; Schenk, L.; Kästner, U.; Frank, F.; Nillius, B.; Bundke, U.; Rose, D.; Curtius, J.; Kupiszewski, P.; Weingartner, E.; Vochezer, P.; Schneider, J.; Schmidt, S.; Weinbruch, S.; Ebert, M.

    2015-04-01

    In the present work, three different techniques to separate ice-nucleating particles (INPs) as well as ice particle residuals (IPRs) from non-ice-active particles are compared. The Ice Selective Inlet (ISI) and the Ice Counterflow Virtual Impactor (Ice-CVI) sample ice particles from mixed-phase clouds and allow after evaporation in the instrument for the analysis of the residuals. The Fast Ice Nucleus Chamber (FINCH) coupled with the Ice Nuclei Pumped Counterflow Virtual Impactor (IN-PCVI) provides ice-activating conditions to aerosol particles and extracts the activated particles for analysis. The instruments were run during a joint field campaign which took place in January and February 2013 at the High Alpine Research Station Jungfraujoch (Switzerland). INPs and IPRs were analyzed offline by scanning electron microscopy and energy-dispersive X-ray microanalysis to determine their size, chemical composition and mixing state. Online analysis of the size and chemical composition of INP activated in FINCH was performed by laser ablation mass spectrometry. With all three INP/IPR separation techniques high abundances (median 20-70%) of instrumental contamination artifacts were observed (ISI: Si-O spheres, probably calibration aerosol; Ice-CVI: Al-O particles; FINCH + IN-PCVI: steel particles). After removal of the instrumental contamination particles, silicates, Ca-rich particles, carbonaceous material and metal oxides were the major INP/IPR particle types obtained by all three techniques. In addition, considerable amounts (median abundance mostly a few percent) of soluble material (e.g., sea salt, sulfates) were observed. As these soluble particles are often not expected to act as INP/IPR, we consider them as potential measurement artifacts. Minor types of INP/IPR include soot and Pb-bearing particles. The Pb-bearing particles are mainly present as an internal mixture with other particle types. Most samples showed a maximum of the INP/IPR size distribution at 200

  16. Design and building of a homemade sample changer for automation of the irradiation in neutron activation analysis technique

    International Nuclear Information System (INIS)

    Gago, Javier; Hernandez, Yuri; Baltuano, Oscar; Bedregal, Patricia; Lopez, Yon; Urquizo, Rafael

    2014-01-01

    Because the RP-10 research reactor operates during weekends, it was necessary to design and build a sample changer for irradiation as part of the automation process of neutron activation analysis technique. The device is formed by an aluminum turntable disk which can accommodate 19 polyethylene capsules, containing samples to be sent using the pneumatic transfer system from the laboratory to the irradiation position. The system is operate by a control switchboard to send and return capsules in a variable preset time and by two different ways, allowing the determination of short, medium and long lived radionuclides. Also another mechanism is designed called 'exchange valve' for changing travel paths (pipelines) allowing the irradiated samples to be stored for a longer time in the reactor hall. The system design has allowed complete automation of this technique, enabling the irradiation of samples without the presence of an analyst. The design, construction and operation of the device is described and presented in this article. (authors).

  17. Microwave Heating of Synthetic Skin Samples for Potential Treatment of Gout Using the Metal-Assisted and Microwave-Accelerated Decrystallization Technique.

    Science.gov (United States)

    Toker, Salih; Boone-Kukoyi, Zainab; Thompson, Nishone; Ajifa, Hillary; Clement, Travis; Ozturk, Birol; Aslan, Kadir

    2016-11-30

    Physical stability of synthetic skin samples during their exposure to microwave heating was investigated to demonstrate the use of the metal-assisted and microwave-accelerated decrystallization (MAMAD) technique for potential biomedical applications. In this regard, optical microscopy and temperature measurements were employed for the qualitative and quantitative assessment of damage to synthetic skin samples during 20 s intermittent microwave heating using a monomode microwave source (at 8 GHz, 2-20 W) up to 120 s. The extent of damage to synthetic skin samples, assessed by the change in the surface area of skin samples, was negligible for microwave power of ≤7 W and more extensive damage (>50%) to skin samples occurred when exposed to >7 W at initial temperature range of 20-39 °C. The initial temperature of synthetic skin samples significantly affected the extent of change in temperature of synthetic skin samples during their exposure to microwave heating. The proof of principle use of the MAMAD technique was demonstrated for the decrystallization of a model biological crystal (l-alanine) placed under synthetic skin samples in the presence of gold nanoparticles. Our results showed that the size (initial size ∼850 μm) of l-alanine crystals can be reduced up to 60% in 120 s without damage to synthetic skin samples using the MAMAD technique. Finite-difference time-domain-based simulations of the electric field distribution of an 8 GHz monomode microwave radiation showed that synthetic skin samples are predicted to absorb ∼92.2% of the microwave radiation.

  18. Microwave Heating of Synthetic Skin Samples for Potential Treatment of Gout Using the Metal-Assisted and Microwave-Accelerated Decrystallization Technique

    Science.gov (United States)

    2016-01-01

    Physical stability of synthetic skin samples during their exposure to microwave heating was investigated to demonstrate the use of the metal-assisted and microwave-accelerated decrystallization (MAMAD) technique for potential biomedical applications. In this regard, optical microscopy and temperature measurements were employed for the qualitative and quantitative assessment of damage to synthetic skin samples during 20 s intermittent microwave heating using a monomode microwave source (at 8 GHz, 2–20 W) up to 120 s. The extent of damage to synthetic skin samples, assessed by the change in the surface area of skin samples, was negligible for microwave power of ≤7 W and more extensive damage (>50%) to skin samples occurred when exposed to >7 W at initial temperature range of 20–39 °C. The initial temperature of synthetic skin samples significantly affected the extent of change in temperature of synthetic skin samples during their exposure to microwave heating. The proof of principle use of the MAMAD technique was demonstrated for the decrystallization of a model biological crystal (l-alanine) placed under synthetic skin samples in the presence of gold nanoparticles. Our results showed that the size (initial size ∼850 μm) of l-alanine crystals can be reduced up to 60% in 120 s without damage to synthetic skin samples using the MAMAD technique. Finite-difference time-domain-based simulations of the electric field distribution of an 8 GHz monomode microwave radiation showed that synthetic skin samples are predicted to absorb ∼92.2% of the microwave radiation. PMID:27917407

  19. A comparative study of 232Th and 238U activity estimation in soil samples by gamma spectrometry and neutron activation analysis technique

    International Nuclear Information System (INIS)

    Anilkumar, Rekha; Anilkumar, S.; Narayani, K.; Babu, D.A.R.; Sharma, D.N.

    2012-01-01

    Neutron activation analysis (NAA) is a well-established analytical technique. It has many advantages as compared to the other commonly used techniques. NAA can be performed in a variety of ways depending on the element, its activity level in the sample, interference from the sample matrix and other elements, etc. This technique is used to get high analytical sensitivity and low detection limits (ppm to ppb). The high sensitivity is due to the irradiation at high neutron flux available from the research reactors and the activity measurement is done using high resolution HPGe detectors. In this paper, the activity estimation of soil samples using neutron activation and direct gamma spectrometry methods are compared. Even though the weights of samples considered and samples preparation methods are different for these two methods, the estimated activity values are comparable. (author)

  20. Elemental analysis of soil and plant samples at El-Manzala lake neutron activation analysis technique. Vol. 4

    Energy Technology Data Exchange (ETDEWEB)

    Eissa, E A; Rofail, N B; Hassan, A M [Reactor and Neutron Physics Department, Nuclear Research Center, Atomic Energy Authority, Cairo (Egypt); Abd El-Haleem, A S [Radiactive Environment Pollution Department, Hot Laboratories Center, Nuclear Research Center, Atomic Energy Authority, Cairo (Egypt); El-Abbady, W H [Phsics Department, Faculty of Science , Al-Azhar University, (Egypt)

    1996-03-01

    Soil and plant samples were collected from from two locations, Bahr El-Baker, and Bahr kados at the manzala lake, where, where high pollution is expected. The samples were especially treated and prepared for investigation by thermal neutron activation analysis (NAA). The irradiation facilities of the first egyptian research reactor (ET-R R-1), and the hyper pure germanium (HPGe) detection system were used for analysis. Among the 34 identified Fe, Co, As, Cd, Te, La, Sm, Rb, Hg, Th, and U are of a special significance because of the their toxic deleterious impact on living organisms. This work is part of a research project concerning pollution studies on the river Nile and some lakes of egypt. The data obtained in the present work stands as a reference basic record for any future follow up of contamination level. 1 tab.

  1. Elemental analysis of soil and plant samples at El-Manzala lake neutron activation analysis technique. Vol. 4

    International Nuclear Information System (INIS)

    Eissa, E.A.; Rofail, N.B.; Hassan, A.M.; Abd El-Haleem, A.S.; El-Abbady, W.H.

    1996-01-01

    Soil and plant samples were collected from from two locations, Bahr El-Baker, and Bahr kados at the manzala lake, where, where high pollution is expected. The samples were especially treated and prepared for investigation by thermal neutron activation analysis (NAA). The irradiation facilities of the first egyptian research reactor (ET-R R-1), and the hyper pure germanium (HPGe) detection system were used for analysis. Among the 34 identified Fe, Co, As, Cd, Te, La, Sm, Rb, Hg, Th, and U are of a special significance because of the their toxic deleterious impact on living organisms. This work is part of a research project concerning pollution studies on the river Nile and some lakes of egypt. The data obtained in the present work stands as a reference basic record for any future follow up of contamination level. 1 tab

  2. Detection, characterization and quantification of inorganic engineered nanomaterials: A review of techniques and methodological approaches for the analysis of complex samples

    Energy Technology Data Exchange (ETDEWEB)

    Laborda, Francisco, E-mail: flaborda@unizar.es; Bolea, Eduardo; Cepriá, Gemma; Gómez, María T.; Jiménez, María S.; Pérez-Arantegui, Josefina; Castillo, Juan R.

    2016-01-21

    The increasing demand of analytical information related to inorganic engineered nanomaterials requires the adaptation of existing techniques and methods, or the development of new ones. The challenge for the analytical sciences has been to consider the nanoparticles as a new sort of analytes, involving both chemical (composition, mass and number concentration) and physical information (e.g. size, shape, aggregation). Moreover, information about the species derived from the nanoparticles themselves and their transformations must also be supplied. Whereas techniques commonly used for nanoparticle characterization, such as light scattering techniques, show serious limitations when applied to complex samples, other well-established techniques, like electron microscopy and atomic spectrometry, can provide useful information in most cases. Furthermore, separation techniques, including flow field flow fractionation, capillary electrophoresis and hydrodynamic chromatography, are moving to the nano domain, mostly hyphenated to inductively coupled plasma mass spectrometry as element specific detector. Emerging techniques based on the detection of single nanoparticles by using ICP-MS, but also coulometry, are in their way to gain a position. Chemical sensors selective to nanoparticles are in their early stages, but they are very promising considering their portability and simplicity. Although the field is in continuous evolution, at this moment it is moving from proofs-of-concept in simple matrices to methods dealing with matrices of higher complexity and relevant analyte concentrations. To achieve this goal, sample preparation methods are essential to manage such complex situations. Apart from size fractionation methods, matrix digestion, extraction and concentration methods capable of preserving the nature of the nanoparticles are being developed. This review presents and discusses the state-of-the-art analytical techniques and sample preparation methods suitable for

  3. Detection, characterization and quantification of inorganic engineered nanomaterials: A review of techniques and methodological approaches for the analysis of complex samples

    International Nuclear Information System (INIS)

    Laborda, Francisco; Bolea, Eduardo; Cepriá, Gemma; Gómez, María T.; Jiménez, María S.; Pérez-Arantegui, Josefina; Castillo, Juan R.

    2016-01-01

    The increasing demand of analytical information related to inorganic engineered nanomaterials requires the adaptation of existing techniques and methods, or the development of new ones. The challenge for the analytical sciences has been to consider the nanoparticles as a new sort of analytes, involving both chemical (composition, mass and number concentration) and physical information (e.g. size, shape, aggregation). Moreover, information about the species derived from the nanoparticles themselves and their transformations must also be supplied. Whereas techniques commonly used for nanoparticle characterization, such as light scattering techniques, show serious limitations when applied to complex samples, other well-established techniques, like electron microscopy and atomic spectrometry, can provide useful information in most cases. Furthermore, separation techniques, including flow field flow fractionation, capillary electrophoresis and hydrodynamic chromatography, are moving to the nano domain, mostly hyphenated to inductively coupled plasma mass spectrometry as element specific detector. Emerging techniques based on the detection of single nanoparticles by using ICP-MS, but also coulometry, are in their way to gain a position. Chemical sensors selective to nanoparticles are in their early stages, but they are very promising considering their portability and simplicity. Although the field is in continuous evolution, at this moment it is moving from proofs-of-concept in simple matrices to methods dealing with matrices of higher complexity and relevant analyte concentrations. To achieve this goal, sample preparation methods are essential to manage such complex situations. Apart from size fractionation methods, matrix digestion, extraction and concentration methods capable of preserving the nature of the nanoparticles are being developed. This review presents and discusses the state-of-the-art analytical techniques and sample preparation methods suitable for

  4. Des images et des paraboles : Niels Bohr et le discours descriptif en physique quantique

    Directory of Open Access Journals (Sweden)

    Ilias Yocaris

    2011-01-01

    Full Text Available Cette étude porte sur l’importance accordée aux images verbales dans le discours descriptif utilisé en mécanique quantique, et plus précisément sur la conception de la langue scientifique qui est celle de Niels Bohr (1885-1962 : en raison d’une série de considérations techniques, méthodologiques et épistémologiques que nous nous proposons d’analyser in extenso, Bohr considère effectivement que les phénomènes subatomiques ne peuvent être évoqués directement (sans référence au contexte observationnel, par le biais d’un langage dénotatif non figural, mais uniquement de manière métaphorique, détournée, ce qui réduit à ses yeux le discours descriptif des physiciens à « des images et des paraboles ». En examinant les textes de Bohr à la lumière d’un certain nombre de travaux épistémologiques, de commentaires et d’expérimentations auxquels ils ont donné lieu ultérieurement, nous nous proposons de décrire les implications conceptuelles d’une telle prise de position, qui constitue une vraie révolution sur le plan philosophique.

  5. Applying squeezing technique to clay-rocks: lessons learned from ten years experiments at Mont Terri

    International Nuclear Information System (INIS)

    Fernandez, A. M.; Melon, A.; Sanchez-Ledesma, D.M.; Tournassat, C.; Gaucher, E.; Astudillo, J.; Vinsot, A.

    2012-01-01

    Document available in extended abstract form only. Argillaceous formations of low permeability are considered in several countries as potential host rocks for the disposal of high level radioactive wastes (HLRW). In order to determine their suitability for waste disposal, evaluations of the hydro-geochemistry and transport mechanisms from such geologic formations to the biosphere must be undertaken. The migration of radionuclides through the geosphere will occur predominantly in the aqueous phase, and hence the pore water chemistry plays an important role in determining ion diffusion characteristics in argillaceous formations. Consequently, a great effort has been made to characterise the pore water chemistry in clay-rocks formations. In the last 10 years various techniques were developed for determining pore water composition of clay-rocks including both direct and indirect methods: 1) In situ pore water sampling (water and gas) from sealed boreholes (Pearson et al., 2003; Vinsot et al. 2008); 2) Laboratory pore water sampling from unaltered core samples by the squeezing technique at high pressures (Fernandez et al., 2009); and 3) Characterization of the water chemistry by geochemical modelling (Gaucher et al. 2009). Pore water chemistry in clay-rocks and extraction techniques were documented and reviewed in different studies (Sacchi et al., 2001). Recovering pristine pore water from low permeable and low water content systems is very difficult and sometimes impossible. Besides, uncertainties are associated to each method used for the pore water characterization. In this paper, a review about the high pressure squeezing technique applied to indurate clay-rocks was performed. For this purpose, the experimental work on Opalinus Clay at the Mont Terri Research Laboratory during the last ten years was evaluated. A complete discussion was made about different issues such as: a) why is necessary to obtain the pore water by squeezing in the context of radioactive waste

  6. Nuclear techniques for trace element analysis. PIXE and its applications to biomedical samples

    International Nuclear Information System (INIS)

    Cata-Danil, I.; Moro, R.; Gialanella, G.

    1996-01-01

    Problems in understanding the role of trace elements in the functioning of life processes are discussed. A brief review of the state of the PIXE technique is given. Principles and recent advances in beam systems, instrumentation and sample handling are covered. A rather comprehensive list of references regarding varies methodological aspects and biomedical applications is given. Some applications are discussed. In particular, preliminary results of an investigation regarding pediatric obesity are presented. (author) 5 tabs., 21 refs

  7. Determination of elements in industrial waste sample and TENORM using XRF Technique in Nuclear Malaysia

    International Nuclear Information System (INIS)

    Paulus, W.; Sarimah Mahat; Meor Yusoff Meor Sulaiman

    2011-01-01

    Industrial waste such as aluminium dross and TENORM waste, oil sludge has been used as sample in this research. Determination of main elements by using X-Ray Fluorescence (XRF) in Material Technology Group, Malaysian Nuclear Agency. Results shows that main elements in these samples, aluminium and silicon, respectively. Thereby, this research shows that XRF can be considered as one of the techniques that can be used in waste characterization and furthermore, it can help researchers and engineer in the research related to waste treatment especially radioactive waste. (author)

  8. Effect of sample preparation techniques on the concentrations and distributions of elements in biological tissues using µSRXRF: a comparative study

    International Nuclear Information System (INIS)

    Al-Ebraheem, A; Dao, E; Desouza, E; McNeill, F E; Farquharson, M J; Li, C; Wainman, B C

    2015-01-01

    Routine tissue sample preparation using chemical fixatives is known to preserve the morphology of the tissue being studied. A competitive method, cryofixation followed by freeze drying, involves no chemical agents and maintains the biological function of the tissue. The possible effects of both sample preparation techniques in terms of the distribution of bio-metals (calcium (Ca), copper (Cu) zinc (Zn), and iron (Fe) specifically) in human skin tissue samples was investigated. Micro synchrotron radiation x-ray fluorescence (μSRXRF) was used to map bio-metal distribution in epidermal and dermal layers of human skin samples from various locations of the body that have been prepared using both techniques. For Ca, Cu and Zn, there were statistically significant differences between the epidermis and dermis using the freeze drying technique (p = 0.02, p < 0.01, and p < 0.01, respectively). Also using the formalin fixed, paraffin embedded technique the levels of Ca, Cu and Zn, were significantly different between the epidermis and dermis layers (p = 0.03, p < 0.01, and p < 0.01, respectively). However, the difference in levels of Fe between the epidermis and dermis was unclear and further analysis was required. The epidermis was further divided into two sub-layers, one mainly composed of the stratum corneum and the other deeper layer, the stratum basale. It was found that the difference between the distribution of Fe in the two epidermal layers using the freeze drying technique resulted in a statistically significant difference (p = 0.012). This same region also showed a difference in Fe using the formalin fixed, paraffin embedded technique (p < 0.01). The formalin fixed, paraffin embedded technique also showed a difference between the deeper epidermal layer and the dermis (p < 0.01). It can be concluded that studies involving Ca, Cu and Zn might show similar results using both sample preparation techniques, however studies involving Fe would need more

  9. Application of neutron activation analysis technique in elemental determination of lichen samples

    International Nuclear Information System (INIS)

    Djoko Prakoso Dwi Atmodjo; Syukria Kurniawati; Woro Yatu Niken Syahfitri; Nana Suherman; Dadang Supriatna

    2010-01-01

    Lichen is one of the biological materials as pollution monitor that can give information about level, direction, and history of various pollutants in environment. Small sample weights and elemental content of lichens is on the order of ppm, so that its characterization requires advanced analytical techniques that has high sensitivity and capable of analyzing samples with weight of - 25 mg, such as neutron activation analysis. In this research, determination of elements was done in lichen samples obtained from Kiaracondong and Holis areas in Bandung city, to understanding the difference of industrial exposure level on surrounding environment. Samples were irradiated in RSG GA Siwabessy, Serpong, at 15 MW for 1-2 and 60 minutes for short irradiation and long irradiation, respectively. The samples were then counted using HPGe detector with GENIE 2000 software. The level of element in lichen for Kiaracondong area were Co, Cr, Cs, Fe, Mg, Mn, Sb, Sc, and V in the range of 0.55-0.86, 1.47-2.57, 0.87-1.19, 540-1005, 949-1674, 34.91-45.94, 0.08-0.14, 0.16-0.31, and ≤ 2.33 mg/kg, respectively, while for Holis area were 1.04-2.37, 4.41-10.36, 0.41-0.89, 3166-709, 1131-1422, 40.97-72.51, 0.33-0.50, 0.98-2.18, and 5.30-13.05 mg/kg respectively. From these results, it is known that pollution exposure from the semi industrial area Holis provide greater influence than in the semi industrial area Kiaracondong. (author)

  10. Gas Well Testing Analysis Using Finite-Difference Models and Optimization Techniques Analyse d'essais de puits de gaz par des modèles utilisant la méthode des différences finies et par des techniques d'optimisation

    Directory of Open Access Journals (Sweden)

    Darderes E. A.

    2006-11-01

    Full Text Available In reservoir engineering studies of gas fields, three important parameters are needed: the permeability-thickness product, the skin factor, and the inertial-turbulent factor. Several methods have been proposed to determine these parameters from gas well tests. The most powerful one is the pseudo-steady state analysis, where a linear dependence on a semilogarithmic plot is found between the real gas pseudo-pressure and time. Another one is the type-curve matching. Both have drawbacks because they can be rigorously applied only to specific cases. An automated type-curve match, which provides a general method to analyze well test data, is presented in this paper. It is based on the adjustment of a numerical model to gas well test data, by means of optimization techniques. The numerical model is the solution of the second order strongly non-linear partial differential equation which rules the radial flow of real gases towards a well. The differential equation is solved by finite-differences, taking into account the variation of gas properties with pressure. In order to simulate any gas well test, appropriate initial and boundary conditions are imposed. The least squares method is used to minimize residual differences between actual pressures measured during test and computed pressures. Two optimization techniques are applied to obtain the best estimate of parameters that minimize the sum of the square of the residuals: the univariate method of Fibonacci [1] and the multivariate method of Marquardt [1, 2]. This procedure is applied to a single-rate and a two-rate drawdown test. Numerical results showed excellent agreement with well test data. Les études de gisements de gaz rendent indispensables la connaissance de trois paramètres importants : la capacité de flux (produit de la perméabilité par l'épaisseur de la couche productrice, l'effet de peau et le facteur d'inertie et de turbulence. On connaît plusieurs méthodes pour déterminer ces

  11. Sport et politique au Senegal, de 2000 a 2012 | Loum | Journal de la ...

    African Journals Online (AJOL)

    Malgré l'existence de structures juridiques, économiques, matérielles, techniques et humaines, la promulgation de texte de lois relatifs au développement et à la promotion du sport et la mise en place de programmes d'actions dans le domaine du sport au nom des politiques sportives , force est de constater que la stratégie ...

  12. Physiologie de l'immunité colostrale chez les porcins et facteurs de ...

    African Journals Online (AJOL)

    1Centre Béninois de la Recherche Scientifique et de l'Innovation, 03 BP 1665 Cotonou, République du Bénin. .... truie sont les interleukines 4, 6, 10 et 12 (IL-4,. IL-6 ...... sur les résultats techniques des truies .... Diagnostic des nouveaux cas.

  13. Effect of DNA extraction methods and sampling techniques on the apparent structure of cow and sheep rumen microbial communities.

    Directory of Open Access Journals (Sweden)

    Gemma Henderson

    Full Text Available Molecular microbial ecology techniques are widely used to study the composition of the rumen microbiota and to increase understanding of the roles they play. Therefore, sampling and DNA extraction methods that result in adequate yields of microbial DNA that also accurately represents the microbial community are crucial. Fifteen different methods were used to extract DNA from cow and sheep rumen samples. The DNA yield and quality, and its suitability for downstream PCR amplifications varied considerably, depending on the DNA extraction method used. DNA extracts from nine extraction methods that passed these first quality criteria were evaluated further by quantitative PCR enumeration of microbial marker loci. Absolute microbial numbers, determined on the same rumen samples, differed by more than 100-fold, depending on the DNA extraction method used. The apparent compositions of the archaeal, bacterial, ciliate protozoal, and fungal communities in identical rumen samples were assessed using 454 Titanium pyrosequencing. Significant differences in microbial community composition were observed between extraction methods, for example in the relative abundances of members of the phyla Bacteroidetes and Firmicutes. Microbial communities in parallel samples collected from cows by oral stomach-tubing or through a rumen fistula, and in liquid and solid rumen digesta fractions, were compared using one of the DNA extraction methods. Community representations were generally similar, regardless of the rumen sampling technique used, but significant differences in the abundances of some microbial taxa such as the Clostridiales and the Methanobrevibacter ruminantium clade were observed. The apparent microbial community composition differed between rumen sample fractions, and Prevotellaceae were most abundant in the liquid fraction. DNA extraction methods that involved phenol-chloroform extraction and mechanical lysis steps tended to be more comparable. However

  14. Importance of sampling design and analysis in animal population studies: a comment on Sergio et al

    Science.gov (United States)

    Kery, M.; Royle, J. Andrew; Schmid, Hans

    2008-01-01

    1. The use of predators as indicators and umbrellas in conservation has been criticized. In the Trentino region, Sergio et al. (2006; hereafter SEA) counted almost twice as many bird species in quadrats located in raptor territories than in controls. However, SEA detected astonishingly few species. We used contemporary Swiss Breeding Bird Survey data from an adjacent region and a novel statistical model that corrects for overlooked species to estimate the expected number of bird species per quadrat in that region. 2. There are two anomalies in SEA which render their results ambiguous. First, SEA detected on average only 6.8 species, whereas a value of 32 might be expected. Hence, they probably overlooked almost 80% of all species. Secondly, the precision of their mean species counts was greater in two-thirds of cases than in the unlikely case that all quadrats harboured exactly the same number of equally detectable species. This suggests that they detected consistently only a biased, unrepresentative subset of species. 3. Conceptually, expected species counts are the product of true species number and species detectability p. Plenty of factors may affect p, including date, hour, observer, previous knowledge of a site and mobbing behaviour of passerines in the presence of predators. Such differences in p between raptor and control quadrats could have easily created the observed effects. Without a method that corrects for such biases, or without quantitative evidence that species detectability was indeed similar between raptor and control quadrats, the meaning of SEA's counts is hard to evaluate. Therefore, the evidence presented by SEA in favour of raptors as indicator species for enhanced levels of biodiversity remains inconclusive. 4. Synthesis and application. Ecologists should pay greater attention to sampling design and analysis in animal population estimation. Species richness estimation means sampling a community. Samples should be representative for the

  15. Geometric Three-Dimensional End-to-Side Microvascular Anastomosis: A Simple and Reproducible Technique.

    Science.gov (United States)

    Ooi, Adrian S H; Butz, Daniel R; Fisher, Sean M; Collier, Zachary J; Gottlieb, Lawrence J

    2018-05-01

     End-to-side (ETS) anastomoses are useful when preservation of distal vascularity is critical. The ideal ETS microanastomosis should maintain a wide aperture and have a smooth take-off point to minimize turbulence, vessel spasm, and thrombogenicity of the suture line. We have developed a unique, dependable, and reproducible geometric technique for ETS anastomoses, and analyze its efficacy in our series of patients.  The geometric ETS technique involves creating a three-dimensional (3D) diamond-shaped defect on the recipient vessel wall, followed by a slit incision of the donor vessel to create a "spatula" fitting this defect. This technique removes sutures from the point of most turbulent blood flow while holding the recipient vessel open with a patch vesselplasty effect. We perform a retrospective review of a single surgeon's experience using this technique.  The geometric 3D ETS technique was used in 87 free flaps with a total of 102 ETS anastomoses in a wide range of cases including head and neck, trunk and genitourinary, and extremity reconstruction. Overall, free flap success rates were 98%.  The geometric 3D ETS technique creates a wide anastomosis, minimizes turbulence-inducing thrombogenicity, and mechanically holds the recipient vessel open. It is reliable and reproducible, and when performed properly has been shown to have high rates of success in a large group of free tissue transfer patients. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Isolation thermique et acoustique des bâtiments réglementation, produits, mise en oeuvre

    CERN Document Server

    Bureau Veritas

    2015-01-01

    Les impératifs d’efficacité énergétique et de confort acoustique dans les bâtiments entraînent de nouvelles réponses constructives et une évolution considérable des matériaux et procédés d’isolation. Tenant compte des derniers DTU parus, ce guide regroupe dans un même volume l’essentiel des dispositions techniques de mise en oeuvre des systèmes d’isolation thermique et phonique des bâtiments. Ainsi cet ouvrage : • apporte l’éclairage nécessaire à la compréhension des réglementations thermique et acoustique ; • définit les exigences à atteindre concernant l’isolement aux bruits aériens intérieurs et extérieurs, les niveaux de bruits de chocs et d’équipements, ainsi que le traitement acoustique des parties communes ; • détaille les techniques d’isolation des toitures étanchées et des couvertures ; • décrit l’isolation thermique des murs par l’intérieur et par l’extérieur. Ce manuel pratique est destiné aux maîtres d’ouvrage et promoteurs qui y tr...

  17. Investigation of an egyptian phosphate ore sample by neutron activation analysis technique

    International Nuclear Information System (INIS)

    Eissa, E.A.; Aly, R.A.; Rofail, N.B.; Hassan, A.M.

    1995-01-01

    A domestic phosphate ore sample has been analysed by means of prompt and delayed gamma-ray spectrometry following the activation by thermal neutron capture technique. The rabbit pneumatic transfer system (RPTS), long irradiation facility and two Pu/Be (2,5 Ci each) neutron sources set-Pu for prompt (n,gamma) were applied. The high purity germanium (HPGe) gamma-ray spectrometer with a personal computer analyzer (PCA) system were used for spectrum measurements. Programmes on the VAX computer were utilized for estimating the elemental concentrations of 22 out of 36 elements identified in this work. 2 tabs

  18. Nitrous Oxide from Combustion and Industry: Chemistry, Emissions and Control Protoxyde d'azote provenant de la combustion et de l'industrie : chimie, émissions et techniques de réduction

    Directory of Open Access Journals (Sweden)

    De Soete G.

    2006-11-01

    ératures élevées. Les émissions des moteurs à combustion interne (moteurs diesel ainsi que moteurs à essence non contrôlés par des catalyseurs trois-voies dépendent de la richesse du mélange (fig. 28 ainsi que de la puissance fournie (fig. 29 et 30; des facteurs d'émission en g/km sont donnés pour les deux types de moteurs (tableaux 7 et 8. Les techniques d'abattement de NO dans les fumées et gaz d'échappement peuvent constituer une source d'accroissement des émissions de N2O non négligeable. En particulier c'est le cas des techniques de réduction sélective non catalytique (NCSR du NO par l'urée et l'acide cyanurique (fig. 31 et 32 et du traitement des gaz d'échappement des moteurs à allumage commandé par des catalyseurs trois-voies (fig. 33 ; dans ce dernier cas, le vieillissement progressif du catalyseur augmente sensiblement le protoxyde d'azote émis (figs. 34 et 35. Par rapport à la voiture sans catalyseur trois-voies, la présence du catalyseur neuf augmente l'émission de N2O par un facteur 3 à 5, tandis que la présence d'un catalyseur moyennement âgé la multiplie par un facteur 10 à 16 (tableaux 9 et 10. Les teneurs de protoxyde d'azote dans les effluves gazeux provenant de la fabrication de l'acide nitrique sont très élevées (300 à 1700 ppmv, tandis que les effluves en provenance des unités de production d'acide adipique (intermédiaire dans la fabrication du nylon peuvent contenir plusieurs dizaines de pour-cents de N2O. L'incinération de certains types de déchets, riche en azote (par exemple les sewage sludges, peuvent également être à l'origine d'émissions relativement importantes (tableau 11. Une Deuxième partie de l'article compare très brièvement ces données actuelles sur les émissions de N2O aux facteurs d'émission présentés dans le Rapport OCDE/IPPC d'août 1991, pour constater que, à part le fait que l'inventaire de ce Rapport présente bien des lacunes, certaines données pourraient encore être contamin

  19. Essai de caractérisation des phénomènes de stalking dans un contexte juridique et politique : radiogoniométrie et filature On characterization of stalking phenomena in a juridical and political context: radiogoniometry and tracking

    Directory of Open Access Journals (Sweden)

    Desurmont N.

    2010-12-01

    Full Text Available De nos jours il est devenu impossible d’étudier les filatures comme on les pratiquait avant la naissance de la triangulation et de la radiogoniométrie, les observations satellitaires, les communications radios, etc. En effet l’usage de la radiogoniométrie et de d’autres techniques par les services des renseignements généraux et les forces de l’ordre biaisent aujourd’hui fortement l’analyse des filatures de ces organes en ayant recours qu’à l’analyse topologique et la géocriminologie. Le présent texte est une version abrégée d’une étude plus complète sur la représentation de l’espace criminel et sur la topographie policière par l’analyse des techniques de filature et de traçabilité. Il cherche à élargir le champ de l’activité de la police scientifique de telle manière à mieux diagnostiquer une série d’infractions impliquant des techniques de poursuites. Bien que beaucoup d’infractions nécessitent, pour être commises, la pratique de techniques de poursuite, c’est essentiellement en se basant sur des infractions telle la recherche et la poursuite, le stalking et le harcèlement moral en réseau (ou harcèlement organisationnel que nous avons pu énoncer les principes de la victimisation organisationnelle.Nowadays it has become impossible to study the technics of stalking as they were practiced before the birth of mobile phone localisation, satellite observations, communications radios, etc.. Indeed the use of mobile phone localization and other techniques by intelligence services and law enforcement officials today strongly distort the analysis of stalking of these organs by using only the topological analysis and geocriminology. This text is a reduced version of a more comprehensive study of the following technics of spatial representation and as well the analysis of police surveillance techniques and traceability. It seeks to broaden the scope of activity of forensic science in such a way as

  20. Dynamique de la flore et de la végétation des Niayes et du Bassin arachidier au Sénégal

    Directory of Open Access Journals (Sweden)

    Elhadji Faye

    2014-12-01

    Full Text Available Reactualisation of floristic and phytosociologic datas in Niayes and Peanut-Basin areas were undertook with village scale approach to better underline resources' conervation. In Savannah and sub-guinean areas specially in the Peanut-Basin and Niayes, 288 floristic samples were put in place in 6 villages in an stratified way based on ethnic groups, land use systems and topography. In the same time, 25 samples were realised in the 2 reference sites (Noflaye and Sambandé and comparison were made with researches conducted in 1940. Datas were submitted to multivariate analysis. SØrensen similarity index were used to compare villages systems and natural sites. Results showed discrimination of 11 phytosociologic groups: 5 of which came from natural sites (savanah G4 Hexalobus monopetalus et Gardenia ternifolia and G8 Acacia macrostachya et Ischaemum rugosum, secondary forest G10 Aphania senegalensis et Voaganca africana, semi-aquatic vegetations G1 Ipomoea aquatica et I. dichroa and G5 Phragmites australis subsp australis et Paspalum vaginatum and 6 from anthropic systems (disturbed areas G6 Echinochloa colona et Jussiae erecta and G7 Dactyloctenium aegyptium et Brachiaria disticophylla, and finally post-cultural zones with G2 Brachiaria disticophylla et Cenchrus biflorus, G3 Celosia trigyna et Digitaria velutina, G9 Tephrosia purpurea et Cenchrus biflorus and G11 Mitracarpus scaber et Eragrostis tremula. Natural sites groups were progressively invided by disturded area species and the others by ruderals and nitrophyl species. Overall floristic richness is about 336 species among which 260 from the Niayes sites and 176 from Peanut-Basin ones. References sites are always richer in terms af genera but peul areas are richer in termes of species. Differences were evidenced between actual taxa and Trochain (1940 descriptions. This methodological approach might be extended to other ecogeographical zones in Senegal in order to better identify and follow

  1. Cryptanalysis of Lin et al.'s Efficient Block-Cipher-Based Hash Function

    NARCIS (Netherlands)

    Liu, Bozhong; Gong, Zheng; Chen, Xiaohong; Qiu, Weidong; Zheng, Dong

    2010-01-01

    Hash functions are widely used in authentication. In this paper, the security of Lin et al.'s efficient block-cipher-based hash function is reviewed. By using Joux's multicollisions and Kelsey et al.'s expandable message techniques, we find the scheme is vulnerable to collision, preimage and second

  2. Effet des techniques de conservation des eaux et des sols, zaï forestier et cordons pierreux, sur la réhabilitation de la végétation herbacée à l'Ouest du Burkina Faso

    DEFF Research Database (Denmark)

    Yameogo, Jérôme T.; Hien, Mipro; Lykke, Anne Mette

    2011-01-01

    Dans la perspective de trouver des solutions pour remédier au problème de dégradation des ressources naturelles en milieu forestier, des techniques de conservation des eaux et des sols ont été appliquées dans la forêt classée de Kuinima, à l’Ouest du Burkina Faso. L’étude a consisté au suivi de l...... espaces aménagés. Ceci témoigne d’une restauration progressive de ces parcelles aménagées....

  3. Molecular dynamics based enhanced sampling of collective variables with very large time steps

    Science.gov (United States)

    Chen, Pei-Yang; Tuckerman, Mark E.

    2018-01-01

    Enhanced sampling techniques that target a set of collective variables and that use molecular dynamics as the driving engine have seen widespread application in the computational molecular sciences as a means to explore the free-energy landscapes of complex systems. The use of molecular dynamics as the fundamental driver of the sampling requires the introduction of a time step whose magnitude is limited by the fastest motions in a system. While standard multiple time-stepping methods allow larger time steps to be employed for the slower and computationally more expensive forces, the maximum achievable increase in time step is limited by resonance phenomena, which inextricably couple fast and slow motions. Recently, we introduced deterministic and stochastic resonance-free multiple time step algorithms for molecular dynamics that solve this resonance problem and allow ten- to twenty-fold gains in the large time step compared to standard multiple time step algorithms [P. Minary et al., Phys. Rev. Lett. 93, 150201 (2004); B. Leimkuhler et al., Mol. Phys. 111, 3579-3594 (2013)]. These methods are based on the imposition of isokinetic constraints that couple the physical system to Nosé-Hoover chains or Nosé-Hoover Langevin schemes. In this paper, we show how to adapt these methods for collective variable-based enhanced sampling techniques, specifically adiabatic free-energy dynamics/temperature-accelerated molecular dynamics, unified free-energy dynamics, and by extension, metadynamics, thus allowing simulations employing these methods to employ similarly very large time steps. The combination of resonance-free multiple time step integrators with free-energy-based enhanced sampling significantly improves the efficiency of conformational exploration.

  4. Formation and characterization of vitreous materials prepared by the sol-gel technique

    International Nuclear Information System (INIS)

    Martinez, J.R.; Ruiz, J.F.; Cruz M, J.A. de la; Villasenor G, P.

    1999-01-01

    A full process of preparation and characterization of silica gel, which can be implemented in a experimental course for undergraduate laboratories is presented. Samples of silica gel and sol-gel derived SiO 2 films on glass substrates were fabricated and characterized using atomic force microscopy, Raman and Infrared absorption techniques. Raman and Infrared spectroscopy were used to analyze the local structure. The microstructure characteristics of the films, fabricated by dip-coating, were monitored using atomic force microscopy. The samples were prepared from alcoholic solutions of tetraethylortosilicate (TEOS) keeping the H 2 O/TEOS and Et-OH/TEOS molar ratios constant and equal to 11.66 and 4 respectively. (Author)

  5. Localisation and identification of radioactive particles in solid samples by means of a nuclear track technique

    International Nuclear Information System (INIS)

    Boehnke, Antje; Treutler, Hanns-Christian; Freyer, Klaus; Schubert, Michael; Holger Weiss

    2005-01-01

    This study is aimed to develop a generally applicable methodology of investigation that can be used for the localisation of single alpha-active particles in solid samples, such as industrial dust or natural soils, sediments and rocks by autoradiography using solid-state nuclear track detectors. The developed technique allows the detection of local enrichments of alpha-emitters in any solid material. The results of such an investigation are of interest from technical, biological and environmental points of view. The idea behind the methodology is to locate the position of alpha-active spots in a sample by attaching the track detector to the sample in a defined manner, thoroughly described in the paper. The located alpha-active particles are subsequently analysed by an electron microscope and an electron microprobe. An example of the application of this methodology is also given. An ultra-fine -grained ore-processing residue, which causes serious environmental pollution in the respective mining district and thus limits possible land use and affects quality of life in the area, was examined using the described technique. The investigation revealed considerable amounts of alpha-active particles in this material

  6. Coacervative extraction as a green technique for sample preparation for the analysis of organic compounds.

    Science.gov (United States)

    Melnyk, A; Wolska, L; Namieśnik, J

    2014-04-25

    One of the present trends in analytical chemistry is miniaturization, which is one of the methods of green analytical chemistry application. A particular emphasis is placed on the elimination of the use of large amounts of organic solvents which are toxic and harmful to the environment, maintaining high efficiency of the extraction process, high recovery values and low values of quantification (LOQ) and detection (LOD) limits. These requirements are fulfilled by coacervative extraction (CAE) technique. In this review, theoretical aspects of the coacervation process are presented along with environmental and bioanalytical applications of this technique, its advantages, limitations and competitiveness with other techniques. Due to its simplicity and rapidity, CAE is an excellent alternative for currently practiced procedures of sample preparation for the analysis of organic compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Positive EtG findings in hair as a result of a cosmetic treatment.

    Science.gov (United States)

    Sporkert, Frank; Kharbouche, Hicham; Augsburger, Marc P; Klemm, Clementine; Baumgartner, Markus R

    2012-05-10

    In a case of a driving ability assessment, hair analysis for ethyl glucuronide (EtG) was requested by the authorities. The person concerned denied alcohol consumption and did not present any clinical sign of alcoholism. However, EtG was found in concentrations of up to 910pg/mg in hair from different sampling dates suggesting an excessive drinking behavior. The person declared to use a hair lotion on a regularly base. To evaluate a possible effect of the hair lotion, prospective blood and urine controls as well as hair sampling of scalp and pubic hair were performed. The traditional clinical biomarkers of ethanol consumption, CDT and GGT, were inconspicuous in three blood samples taken. EtG was not detected in all collected urine samples. The hair lotion was transmitted to our laboratory. The ethanol concentration in this lotion was determined with 35g/L. The EtG immunoassay gave a positive result indicating EtG, which could be confirmed by GC-MS/MS-NCI. In a follow-up experiment the lotion was applied to the hair of a volunteer over a period of six weeks. After this treatment, EtG could be measured in the hair at a concentration of 72pg/mg suggesting chronic and excessive alcohol consumption. Overnight incubation of EtG free hair in the lotion yielded an EtG concentration of 140pg/mg. In the present case, the positive EtG hair findings could be interpreted as the result of an EtG containing hair care product. To our knowledge, the existence of such a product has not yet been reported, and it is exceptionally unusual to find EtG in cosmetics. Therefore, external sources for hair contamination should always be taken into account when unusual cosmetic treatment is mentioned. In those cases, it is recommended to analyze the hair product for a possible contamination with EtG. The analysis of body hair can help to reveal problems occurring from cosmetic treatment of head hair. As a consequence, the assessment of drinking behavior should be based on more than one

  8. Sampling and examination methods used for TMI-2 samples

    International Nuclear Information System (INIS)

    Marley, A.W.; Akers, D.W.; McIsaac, C.V.

    1988-01-01

    The purpose of this paper is to summarize the sampling and examination techniques that were used in the collection and analysis of TMI-2 samples. Samples ranging from auxiliary building air to core debris were collected and analyzed. Handling of the larger samples and many of the smaller samples had to be done remotely and many standard laboratory analytical techniques were modified to accommodate the extremely high radiation fields associated with these samples. The TMI-2 samples presented unique problems with sampling and the laboratory analysis of prior molten fuel debris. 14 refs., 8 figs

  9. Contributions from the data samples in NOC technique on the extracting of the Sq variation

    Science.gov (United States)

    Wu, Yingyan; Xu, Wenyao

    2015-04-01

    The solar quiet daily variation, Sq, a rather regular variation is usually observed at mid-low latitudes on magnetic quiet days or less-disturbed days. It is mainly resulted from the dynamo currents in the ionospheric E region, which are driven by the atmospheric tidal wind and different processes and flow as two current whorls in each of the northern and southern hemispheres[1]. The Sq exhibits a conspicuous day-to-day (DTD) variability in daily range (or strength), shape (or phase) and its current focus. This variability is mainly attributed to changes in the ionospheric conductivity and tidal winds, varying with solar radiation and ionospheric conditions. Furthermore, it presents a seasonal variation and solar cycle variation[2-4]. In generally, Sq is expressed with the average value of the five international magnetic quiet days. Using data from global magnetic stations, equivalent current system of daily variation can be constructed to reveal characteristics of the currents[5]. In addition, using the differences of H component at two stations on north and south side of the Sq currents of focus, Sq is extracted much better[6]. Recently, the method of Natural Orthoganal Components (NOC) is used to decompose the magnetic daily variation and express it as the summation of eigenmodes, and indicate the first NOC eigenmode as the solar quiet daily variation, the second as the disturbance daily variation[7-9]. As we know, the NOC technique can help reveal simpler patterns within a complex set of variables, without designed basic-functions such as FFT technique. But the physical explanation of the NOC eigenmodes is greatly depends on the number of data samples and data regular-quality. Using the NOC method, we focus our present study on the analysis of the hourly means of the H component at BMT observatory in China from 2001 to 2008. The contributions of the number and the regular-quality of the data samples on which eigenmode corresponds to the Sq are analyzed, by

  10. Reverse sample genome probing, a new technique for identification of bacteria in environmental samples by DNA hybridization, and its application to the identification of sulfate-reducing bacteria in oil field samples

    International Nuclear Information System (INIS)

    Voordouw, G.; Voordouw, J.K.; Karkhoff-Schweizer, R.R.; Fedorak, P.M.; Westlake, D.W.S.

    1991-01-01

    A novel method for identification of bacteria in environmental samples by DNA hybridization is presented. It is based on the fact that, even within a genus, the genomes of different bacteria may have little overall sequence homology. This allows the use of the labeled genomic DNA of a given bacterium (referred to as a standard) to probe for its presence and that of bacteria with highly homologous genomes in total DNA obtained from an environmental sample. Alternatively, total DNA extracted from the sample can be labeled and used to probe filters on which denatured chromosomal DNA from relevant bacterial standards has been spotted. The latter technique is referred to as reverse sample genome probing, since it is the reverse of the usual practice of deriving probes from reference bacteria for analyzing a DNA sample. Reverse sample genome probing allows identification of bacteria in a sample in a single step once a master filter with suitable standards has been developed. Application of reverse sample genome probing to the identification of sulfate-reducing bacteria in 31 samples obtained primarily from oil fields in the province of Alberta has indicated that there are at least 20 genotypically different sulfate-reducing bacteria in these samples

  11. Issues in the analyze of low content gold mining samples by fire assay technique

    Science.gov (United States)

    Cetean, Valentina

    2016-04-01

    The classic technique analyze of samples with low gold content - below 0.1 g/t (=100 ppb = parts per billion), either ore or gold sediments, involves the preparation of sample by fire assay extraction, followed by the chemical attack with aqua regia (hydrochloric and nitric acid) and measuring the gold content by atomic absorption spectrometry or inductively coupled mass spectrometry. The issues raised by this analysis are well known for the world laboratories, commercial or research ones. The author's knowledge regarding this method of determining the gold content, accumulated in such laboratory from Romania (with more than 40 years of experience, even if not longer available from 2014) confirms the obtaining of reliable results required a lot of attention, amount of work and the involving of an experienced fire assayer specialist. The analytical conclusion for a research laboratory is that most reliable and statistically valid results are till reached for samples with more than 100 ppb gold content; the degree of confidence below this value is lower than 90%. Usually, for samples below 50 ppb, it does not exceed 50-70 %, unless without very strictly control of each stage, that involve additional percentage of hours allocated for successive extracting tests and knowing more precisely the other compounds that appear in the sample (Cu, Sb, As, sulfur / sulphides, Te, organic matter, etc.) or impurities. The most important operation is the preparation, namely: - grinding and splitting of sample (which can cause uneven distribution of gold flakes in the double samples for analyzed); - pyro-metallurgical recovery of gold = fire assay stage, involving the more precise temperature control in furnace during all stages (fusion and cupellation) and adjusting of the fire assay flux components to produce a successful fusion depending of the sample matrix and content; - reducing the sample weight to decrease the amount of impurities that can be concentrated in the lead button

  12. Soil sampling

    International Nuclear Information System (INIS)

    Fortunati, G.U.; Banfi, C.; Pasturenzi, M.

    1994-01-01

    This study attempts to survey the problems associated with techniques and strategies of soil sampling. Keeping in mind the well defined objectives of a sampling campaign, the aim was to highlight the most important aspect of representativeness of samples as a function of the available resources. Particular emphasis was given to the techniques and particularly to a description of the many types of samplers which are in use. The procedures and techniques employed during the investigations following the Seveso accident are described. (orig.)

  13. Use of multiple attributes decision-making Technique for Order Preference by Similarity to Ideal Solution (TOPSIS for Ghare-Gheshlagh calcite in determination of optimum geochemical sampling sites

    Directory of Open Access Journals (Sweden)

    Mansour Rezaei Azizi

    2015-04-01

    for green, white and pink calcites were varied 0.087, 0.247 and 0.997 respectively. The low amounts of Eu anomaly for green and white calcites attributed to low rock/fluid ratio (Nesbitt et al., 1990 and relatively more pH value (Cheng et al., 2013, however, increasing the Eu anomaly may be due to high rock/fluid ratio and less pH value. Ce anomalies are 0.0241, 0.0113 and 0.0131 in pink, white and green calcites respectively. The most negative Ce anomaly values show that calcite have precipitated under reduction conditions (Nesbitt et al., 1990. Discussion Recently, multiple attributes decision-making techniques help scientist to solve decision-making problems related to various controlling factors (Zhijun et al., 2013. One of these techniques is a Technique for Order Preference by Similarity to Ideal Solution (TOPSIS which is a quantitative weighted method (Momenei 2006. The identified criteria are CaO abundant in solution (C1, Eu anomaly (C2, Ce anomaly (C3, Sr abundant (C4 and volume (C5. The Index-Rock matrix also includes A1, A2 and A3 alternatives; as pink, green and white calcite respectively. The weighted normalized decision matrix can be calculated by multiplying the normalized evaluation matrix with its associated weight to obtain the result. The result show that Eu anomaly, volume, Sr abundant and Ce anomaly in order have higher role to investigate the geochemical study of area. Calculation of the relative closeness to the ideal solution (Cl * for pink, green and white calcites are 0.837, 0.445 and 0.157 respectively. It can be deduced that the most preferable calcite to be sampled for investigating geochemically are pink and green calcites. References Cheng, D.L., Jiang-haob, L., Shou-pengc, Z., Lianga, L., Zhao-bina, Y., Guo-lina, G. and Tinga, L., 2013. Geochemical characteristics of calcite and dolomite in sandstone of Dongying Sinking, Shandong Province, China. Procedia Earth and Planetary Science, 7(4: 504 – 507. Eftekharnezhad, J., 1973

  14. Profil épidémiologique, diagnostique, thérapeutique et évolutif du ...

    African Journals Online (AJOL)

    K. Tengue

    Épidémiologie diagnostic;. Traitement; ... soit 6,4 % et le traitement hormonal dans 93,1 % des cas. Le taux de décès .... avaient permis la recherche de localisation secondaire et la classi- .... de plateau technique adéquat dans nos structures.

  15. Functional ET(A)-ET(B) Receptor Cross-talk in Basilar Artery In Situ From ET(B) Receptor Deficient Rats.

    Science.gov (United States)

    Yoon, SeongHun; Gariepy, Cheryl E; Yanagisawa, Masashi; Zuccarello, Mario; Rapoport, Robert M

    2016-03-01

    The role of endothelin (ET)(A)-ET(B) receptor cross-talk in limiting the ET(A) receptor antagonist inhibition of ET-1 constriction is revealed by the partial or complete dependency of the ET(A) receptor antagonist inhibition on functional removal of the ET(B) receptor. Although functional removal of the ET(B) receptor is generally accomplished with ET(B) receptor antagonist, a novel approach using rats containing a naturally occurring deletion mutation in the ET(B) receptor [rescued "spotting lethal" (sl) rats; ET(B)(sl/sl)] demonstrated increased ET(A) receptor antagonist inhibition of ET-1 constriction in vena cava. We investigated whether this deletion mutation was also sufficient to remove the ET(B) receptor dependency of the ET(A) receptor antagonist inhibition of ET-1 constriction in the basilar artery. Consistent with previous reports, ET-1 plasma levels were elevated in ET(B)(sl/sl) as compared with ET(B)(+/+) rats. ET(B) receptor antagonist failed to relax the ET-1 constricted basilar artery from ET(B)(+/+) and ET(B)(sl/sl) rats. Relaxation to combined ET(A) and ET(B) receptor antagonist was greater than relaxation to ET(A) receptor antagonist in the basilar artery from ET(B)(+/+) and, unexpectedly, ET(B)(sl/sl) rats. These findings confirm the presence of ET(A)-ET(B) receptor cross-talk in the basilar artery. We speculate that mutant ET(B) receptor expression produced by alternative splicing may be sufficient to allow cross-talk.

  16. Improved phylogenomic taxon sampling noticeably affects nonbilaterian relationships.

    Science.gov (United States)

    Pick, K S; Philippe, H; Schreiber, F; Erpenbeck, D; Jackson, D J; Wrede, P; Wiens, M; Alié, A; Morgenstern, B; Manuel, M; Wörheide, G

    2010-09-01

    Despite expanding data sets and advances in phylogenomic methods, deep-level metazoan relationships remain highly controversial. Recent phylogenomic analyses depart from classical concepts in recovering ctenophores as the earliest branching metazoan taxon and propose a sister-group relationship between sponges and cnidarians (e.g., Dunn CW, Hejnol A, Matus DQ, et al. (18 co-authors). 2008. Broad phylogenomic sampling improves resolution of the animal tree of life. Nature 452:745-749). Here, we argue that these results are artifacts stemming from insufficient taxon sampling and long-branch attraction (LBA). By increasing taxon sampling from previously unsampled nonbilaterians and using an identical gene set to that reported by Dunn et al., we recover monophyletic Porifera as the sister group to all other Metazoa. This suggests that the basal position of the fast-evolving Ctenophora proposed by Dunn et al. was due to LBA and that broad taxon sampling is of fundamental importance to metazoan phylogenomic analyses. Additionally, saturation in the Dunn et al. character set is comparatively high, possibly contributing to the poor support for some nonbilaterian nodes.

  17. Répartition et abondance des sargasses Sargassum natans et ...

    African Journals Online (AJOL)

    Ces plantes se retrouvent en abondance en mai et en juin sur toutes les plages du pays et particulièrement sur les plages du secteur littoral centre et oriental et les complexes lagunaires Aby-Tendo-Ehy et Grand-Lahou. Leur expansion en mai dans tous les milieux est favorisée par la salinité, la lumière, la température et ...

  18. Technique for preparation of transmission electron microscope specimens from wire samples of Al and Al-Al2O3 alloys

    DEFF Research Database (Denmark)

    Lindbo, Jørgen

    1966-01-01

    A technique for thinning 1 mm wire samples of aluminium and aluminium-alumina alloys for transmission electron microscopy is described. The essential feature of the technique, which involves spark machining and electropolishing in a polytetrafluoroethylene holder followed by chemical polishing...

  19. Non destructive multi elemental analysis using prompt gamma neutron activation analysis techniques: Preliminary results for concrete sample

    Energy Technology Data Exchange (ETDEWEB)

    Dahing, Lahasen Normanshah [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia and Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia); Yahya, Redzuan [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia); Yahya, Roslan; Hassan, Hearie [Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia)

    2014-09-03

    In this study, principle of prompt gamma neutron activation analysis has been used as a technique to determine the elements in the sample. The system consists of collimated isotopic neutron source, Cf-252 with HPGe detector and Multichannel Analysis (MCA). Concrete with size of 10×10×10 cm{sup 3} and 15×15×15 cm{sup 3} were analysed as sample. When neutrons enter and interact with elements in the concrete, the neutron capture reaction will occur and produce characteristic prompt gamma ray of the elements. The preliminary result of this study demonstrate the major element in the concrete was determined such as Si, Mg, Ca, Al, Fe and H as well as others element, such as Cl by analysis the gamma ray lines respectively. The results obtained were compared with NAA and XRF techniques as a part of reference and validation. The potential and the capability of neutron induced prompt gamma as tool for multi elemental analysis qualitatively to identify the elements present in the concrete sample discussed.

  20. Christian Delporte, Image et politique en France au XXe siècle

    OpenAIRE

    Kéita, Sékouna

    2013-01-01

    Dans cet ouvrage, l’auteur revient sur le rôle de l’image en tant qu’outil de communication mais aussi comme instrument de persuasion et de manipulation politique. Il s’agit d’une réflexion approfondie sur les fonctions politiques des documents visuels (image télévisuelle, cinéma, photographie, dessin et caricature etc.) dans leur évolution à travers le xxe siècle. Une évolution du traitement et du rôle de l’image parallèle aux progrès techniques et technologiques de la société. L’image conna...

  1. Analyse spatiale, évaluation et cartographie du risque glissement de terrain

    OpenAIRE

    Malet , Jean-Philippe; Thiery , Yannick; Maquaire , Olivier; Puissant , Anne

    2006-01-01

    International audience; RÉSUMÉ : Pour évaluer et cartographier le risque « glissement de terrain », les techniques d'analyse spatiale et les technologies SIG sont rarement utilisées. En particulier, aucune étude concerne la cartographie automatique du risque « glissement de terrain » à grande échelle (1:10,000 è), échelle de travail correspondant à la cartographie règlementaire du risque naturel en France. Cet article présente une procédure en trois étapes pour évaluer et cartographier le ris...

  2. Meetings and technical workshops; Rencontres et journees techniques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    The conference is composed of 14 communications grouped in 9 sessions which titles and themes are: an approach to rehabilitation objectives through the example of hydrocarbon polluted sites; characterization of polluted sites (methods and tools); risk analysis and selection of rehabilitation schemes; an approach to hygiene and safety aspects of de-polluting yards; methods for selection of polluted sites treatment; selection and validation of biological treatment processes; implementation of polluted site confinement techniques; market analysis concerning polluted site treatment

  3. Meetings and technical workshops; Rencontres et journees techniques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The conference is composed of 14 communications grouped in 9 sessions which titles and themes are: an approach to rehabilitation objectives through the example of hydrocarbon polluted sites; characterization of polluted sites (methods and tools); risk analysis and selection of rehabilitation schemes; an approach to hygiene and safety aspects of de-polluting yards; methods for selection of polluted sites treatment; selection and validation of biological treatment processes; implementation of polluted site confinement techniques; market analysis concerning polluted site treatment

  4. Importance Sampling for a Markov Modulated Queuing Network with Customer Impatience until the End of Service

    Directory of Open Access Journals (Sweden)

    Ebrahim MAHDIPOUR

    2009-01-01

    Full Text Available For more than two decades, there has been a growing of interest in fast simulation techniques for estimating probabilities of rare events in queuing networks. Importance sampling is a variance reduction method for simulating rare events. The present paper carries out strict deadlines to the paper by Dupuis et al for a two node tandem network with feedback whose arrival and service rates are modulated by an exogenous finite state Markov process. We derive a closed form solution for the probability of missing deadlines. Then we have employed the results to an importance sampling technique to estimate the probability of total population overflow which is a rare event. We have also shown that the probability of this rare event may be affected by various deadline values.

  5. Decomposition techniques

    Science.gov (United States)

    Chao, T.T.; Sanzolone, R.F.

    1992-01-01

    Sample decomposition is a fundamental and integral step in the procedure of geochemical analysis. It is often the limiting factor to sample throughput, especially with the recent application of the fast and modern multi-element measurement instrumentation. The complexity of geological materials makes it necessary to choose the sample decomposition technique that is compatible with the specific objective of the analysis. When selecting a decomposition technique, consideration should be given to the chemical and mineralogical characteristics of the sample, elements to be determined, precision and accuracy requirements, sample throughput, technical capability of personnel, and time constraints. This paper addresses these concerns and discusses the attributes and limitations of many techniques of sample decomposition along with examples of their application to geochemical analysis. The chemical properties of reagents as to their function as decomposition agents are also reviewed. The section on acid dissolution techniques addresses the various inorganic acids that are used individually or in combination in both open and closed systems. Fluxes used in sample fusion are discussed. The promising microwave-oven technology and the emerging field of automation are also examined. A section on applications highlights the use of decomposition techniques for the determination of Au, platinum group elements (PGEs), Hg, U, hydride-forming elements, rare earth elements (REEs), and multi-elements in geological materials. Partial dissolution techniques used for geochemical exploration which have been treated in detail elsewhere are not discussed here; nor are fire-assaying for noble metals and decomposition techniques for X-ray fluorescence or nuclear methods be discussed. ?? 1992.

  6. Evaluation of diesel particulate matter sampling techniques

    CSIR Research Space (South Africa)

    Pretorius, CJ

    2011-09-01

    Full Text Available The study evaluated diesel particulate matter (DPM) sampling methods used in the South African mining industry. The three-piece cassette respirable, open face and stopper sampling methods were compared with the SKC DPM cassette method to find a...

  7. Contribution a l'etude des determinants socioculturels et ...

    African Journals Online (AJOL)

    ... a consisté à l'élaboration des outils de collecte et son administration par les techniques variées ... Les résultats obtenus montrent que les facteurs explicatifs de la ... Thus, within the framework of this research, the comparative analysis of the ...

  8. A simple technique for measuring the superconducting critical temperature of small (>= 10 μg) samples

    International Nuclear Information System (INIS)

    Pereira, R.F.R.; Meyer, E.; Silveira, M.F. da.

    1983-01-01

    A simple technique for measuring the superconducting critical temperature of small (>=10μg) samples is described. The apparatus is built in the form of a probe, which can be introduced directly into a liquid He storage dewar and permits the determination of the critical temperature, with an imprecision of +- 0.05 K above 4.2 K, in about 10 minutes. (Author) [pt

  9. L’excellence : impossible sans un personnel stable et expérimenté

    CERN Multimedia

    Association du personnel

    2013-01-01

    Le monde entier avait les yeux fixés sur le CERN ce 4 juillet 2012, quand ATLAS et CMS ont annoncé leur découverte d’une particule « compatible avec le Higgs ». Début 2013 il n’a fallu que quelques jours pour régler le LHC et faire tourner des protons et des ions lourds. Toutes ces découvertes et prouesses techniques n’ont été possibles que grâce à l’expérience et la poursuite de l’excellence d’équipes soudées de techniciens et ingénieurs qui ont conçu, construit, mis en marche, et finalement font fonctionner ce complexe d’accélérateurs unique au monde. Un service d’excellence avec un encadrement adéquat Entre 2002 et 2012 (voir Fig. 1), le nombre d’utilisateurs est passé de 5912 à...

  10. Sampling practices and analytical techniques used in the monitoring of steam and water in CEGB nuclear boilers

    International Nuclear Information System (INIS)

    Goodfellow, G.I.

    1978-01-01

    The steam and water in CEGB Magnox and AGR nuclear boilers are continuously monitored, using both laboratory techniques and on-line instrumentation, in order to maintain the chemical quality within pre-determined limits. The sampling systems in use and some of the difficulties associated with sampling requirements are discussed. The relative merits of chemical instruments installed either locally in various parts of the plant or in centralized instrument rooms are reviewed. The quality of water in nuclear boilers, as with all high-pressure steam-raising plant, is extremely high; consequently very sensitive analytical procedures are required, particularly for monitoring the feed-water of 'once-through boiler' systems. Considerable progress has been made in this field and examples are given of some of the techniques developed for analyses at the 'μ/kg' level together with some of the current problems.(author)

  11. Relativité générale et astrophysique problèmes et exercices corrigés

    CERN Document Server

    Gialis, Denis

    2015-01-01

    La relativité générale a entraîné une mutation en physique. Il existe de bons ouvrages de cours mais des calculs mathématiques délicats sont souvent nécessaires pour s'approprier la physique sous-jacente. Le pari est ici de proposer un apprentissage par la pratique à la fois du raisonnement et du calcul. Sont ainsi proposées de nombreuses démonstrations, certaines classiques et d autres moins courantes. Le livre couvre les bases habituelles (géométrie différentielle, calcul tensoriel, espace-temps) avec des exemples de la métrique de Schwarzschild (les trous noirs), l'espace-temps de Kerr, les ondes gravitationnelles, les modèles de matière et les bases de l'électromagnétisme... On notera également quelques sujets plus avancés (dualité de Hodge, formalisme 3 +1...). Les solutions proposées sont très détaillées tant sur le plan des techniques de calcul que sur l'interprétation physique. Elles permettent ainsi d acquérir une réelle autonomie pour comprendre les concepts de base et �...

  12. Statistical sampling techniques as applied to OSE inspections

    International Nuclear Information System (INIS)

    Davis, J.J.; Cote, R.W.

    1987-01-01

    The need has been recognized for statistically valid methods for gathering information during OSE inspections; and for interpretation of results, both from performance testing and from records reviews, interviews, etc. Battelle Columbus Division, under contract to DOE OSE has performed and is continuing to perform work in the area of statistical methodology for OSE inspections. This paper represents some of the sampling methodology currently being developed for use during OSE inspections. Topics include population definition, sample size requirements, level of confidence and practical logistical constraints associated with the conduct of an inspection based on random sampling. Sequential sampling schemes and sampling from finite populations are also discussed. The methods described are applicable to various data gathering activities, ranging from the sampling and examination of classified documents to the sampling of Protective Force security inspectors for skill testing

  13. Techniques for sampling nuclear waste tank contents and in situ measurement of activity

    International Nuclear Information System (INIS)

    Lawrence, R.C.

    1978-04-01

    A study was conducted to develop suitable sampling equipment and techniques for characterizing the mechanical properties of nuclear wastes; identifying effective means of measuring radiation levels, temperatures, and neutron fluxes in situ in wastes; and developing a waste core sampler. A portable, stainless steel probe was developed which is placed in the tank through a riser. This probe is built for the insertion of instrumentation that can measure the contents of the tank at any level and take temperature, radiation, and neutron activation readings with reliable accuracy. A simple and reliable instrument for the in situ extraction of waste materials ranging from liquid to concrete-like substances was also developed. This portable, stainless steel waste core sampler can remove up to one liter of radioactive waste from tanks for transportation to hot cell laboratories for analysis of hardness, chemical form, and isotopic content. A cask for transporting the waste samples from the tanks to the laboratory under radiation-protected conditions was also fabricated. This cask was designed with a ''boot'' or inner-seal liner to contain any radioactive wastes that might remain on the outside of the waste core sampling device

  14. Analysis of stainless steel samples by energy dispersive X-ray ...

    Indian Academy of Sciences (India)

    Unknown

    the total sample mass absorption coefficients for X-ray energies E0, Ej and ... from published literature (McMaster et al 1969; Bam- bynek et al 1972). .... Table 1. Concentrations of CRM samples determined by EDXRF and VES. Concentrations ...

  15. The development and use of parametric sampling techniques for probabilistic risk assessment

    International Nuclear Information System (INIS)

    Dalrymple, G.J.; Broyd, T.W.

    1987-01-01

    In order to enable evaluation to be made of proposals for the underground disposal of low and intermediate level radioactive wastes in the United Kingdom, the Department of the Environment (DoE) research programme includes development of computer-based methods for use in a multistage assessment process. To test the adequacy of the various methods of data acquisitions and radiological assessment a mock assessment exercise is currently being conducted by the department. This paper outlines the proposed methodology which provides for the use of probabilistic modelling based upon the Atomic Energy of Canada Ltd SYVAC variability analysis approach using new models (SYVAC 'A') and data appropriate to UK conditions for a deep horizontal tunnel repository concept. This chapter describes the choice of a suitable technique for the sampling of data input to the SYVAC 'A' model and techniques for analysing the predictions of dose and risk made by the model. The sensitivity of the model predictions (risk and dose to man) to the input parameters was compared for four different methods. All four methods identified the same geological parameters as the most important. (author)

  16. X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

    Science.gov (United States)

    Ziegler, R. A.; Almeida, N. V.; Sykes, D.; Smith, C. L.

    2014-01-01

    X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass

  17. Des tables pascales aux tables astronomiques et retour.

    Directory of Open Access Journals (Sweden)

    Max Lejbowicz

    2006-05-01

    Full Text Available L’article étudie la naissance et le développement du calendrier ecclésiastique chrétien, i. e. le comput, depuis les premiers témoignages de la célébration annuelle de la résurrection de Jésus jusqu’aux traductions des tables astronomiques arabes au xiie siècle. Il privilégie les procédures qui aboutissent à la détermination des dates pascales et à leur mise en forme tabulaire. Les analyses sont conduites à partir d’un double point de vue. L’un est scientifique. Il s’appuie sur les données astronomiques retenues par Ptolémée et sur l’apport de la tradition mathématique grecque au calcul par approximations. Les cycles soli-lunaires sont posés à partir des fractions continues et le cycle soli-hebdomadaire à partir du plus petit commun multiple. Le second point de vue est social : l’unification du comput participe à celle de la chrétienté comprise comme une configuration politico-religieuse. Deux conclusions s’imposent. Quelle que soit l’importance que la civilisation médiévale a attribuée au comput, il reste que : 1 / les Pâques sont porteuses de significations irréductibles aux techniques chronométriques qui inscrivent cette fête dans le déroulement de l’année ; 2 / ces techniques ont toutefois marqué profondément les curiosités intellectuelles des Latins et les ont préparé à accueillir avec ferveur les zīj et la numération de position.The article studies the birth and development of the Christian ecclesiastical calendar, i.e. the computus, from the first witnesses to the yearly celebration of the resurrection of Jesus to the translations of arabic astronomical tables in the 12th century. It focuses on the procedures which resulted in determinig the dates of Easter and their being put into tabular form. These analyses were undertaken from two perspectives. One was scientific, relying on the astronomical data preserved by Ptolemy and on the contribution of the Greek mathematical

  18. Geochemistry and ore prospecting; Geochimie et prospection miniere

    Energy Technology Data Exchange (ETDEWEB)

    Le Caignec, R. [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    Applied geochemistry is a new technique which helps the geologist in detecting ore deposits. Some deposits, even when they are covered with rather thick surface structures, form around these zones where the infinitesimal content of some elements of soils or waters is notably different. These 'anomalies' may be contemporaneous to the deposit-structure (primary dispersion) or may have occurred later (secondary dispersion). Various factors rule these anomalies: ore-stability, soil homogeneity, water conditions, topography, vegetation, etc... Applied geochemistry is in fact the study of analysis techniques of metal traces in soils as well as the geological interpretation of observed anomalies. This report gives practical data on sampling methods, yields, costs and also on special problems of uranium geochemistry. (author) [French] La geochimie appliquee est une nouvelle technique qui vient aider le geologue dans la detection des gisements de minerais. Certains gisements, meme lorsqu'ils sont recouverts par des formations superficielles relativement epaisses, creent autour d'eux des zones ou la teneur infinitesimale des sols ou des eaux en certains elements varie notablement. Ces ''anomalies'' peuvent etre contemporaines de la formation du gisement (dispersion primaire) ou posterieures a celle-ci (dispersion secondaire). De nombreux facteurs gouvernent ces anomalies: stabilite du minerai, homogeneite du sol, regime des eaux, topographie, vegetation, etc... L'etude des techniques d'analyse des traces de metaux dans les sols et l'interpretation geologique des anomalies obtenues constituent la geochimie appliquee. Ce rapport contient, en outre, des donnees pratiques sur les procedes d'echantillonnage, le rendement, les prix de revient, ainsi que sur quelques problemes particuliers a la geochimie de l'uranium. (auteur)

  19. Geochemistry and ore prospecting; Geochimie et prospection miniere

    Energy Technology Data Exchange (ETDEWEB)

    Le Caignec, R [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    Applied geochemistry is a new technique which helps the geologist in detecting ore deposits. Some deposits, even when they are covered with rather thick surface structures, form around these zones where the infinitesimal content of some elements of soils or waters is notably different. These 'anomalies' may be contemporaneous to the deposit-structure (primary dispersion) or may have occurred later (secondary dispersion). Various factors rule these anomalies: ore-stability, soil homogeneity, water conditions, topography, vegetation, etc... Applied geochemistry is in fact the study of analysis techniques of metal traces in soils as well as the geological interpretation of observed anomalies. This report gives practical data on sampling methods, yields, costs and also on special problems of uranium geochemistry. (author) [French] La geochimie appliquee est une nouvelle technique qui vient aider le geologue dans la detection des gisements de minerais. Certains gisements, meme lorsqu'ils sont recouverts par des formations superficielles relativement epaisses, creent autour d'eux des zones ou la teneur infinitesimale des sols ou des eaux en certains elements varie notablement. Ces ''anomalies'' peuvent etre contemporaines de la formation du gisement (dispersion primaire) ou posterieures a celle-ci (dispersion secondaire). De nombreux facteurs gouvernent ces anomalies: stabilite du minerai, homogeneite du sol, regime des eaux, topographie, vegetation, etc... L'etude des techniques d'analyse des traces de metaux dans les sols et l'interpretation geologique des anomalies obtenues constituent la geochimie appliquee. Ce rapport contient, en outre, des donnees pratiques sur les procedes d'echantillonnage, le rendement, les prix de revient, ainsi que sur quelques problemes particuliers a la geochimie de l'uranium. (auteur)

  20. Entre structure et action : la compétence communicative des TIC

    Directory of Open Access Journals (Sweden)

    Serge Agostinelli

    2011-06-01

    Full Text Available Cet article théorique explore comment les concepts de structure et d’action permettent une approche originale du concept de compétence dans le domaine des TIC. Cette approche relève d’une recherche de compatibilité entre des modèles issus des Technologies qui proposent les structures socio-techniques et ceux des Sciences Humaines qui organisent l’action des individus. Les modèles théoriques invoqués de domaines disciplinaires différents (sociologie, ethnométhodologie, psychologie sociale, linguistique, sciences de l’éducation et sciences de l’information-communication donnent au concept de compétence en TIC une nouvelle consistance, plus anthropocentrée et moins technico-pratique. Ils posent la question du rapport entre micro et macro, du rapport de l’individu au groupe, et posent aussi la question ontologique des structures. Les compétences ne se réduisent pas à la seule connaissance des aspects techniques, mais sont élargies à la maîtrise des conditions d’utilisation adéquate et des possibilités offertes par la technique. Utiliser les technologies, c’est construire de la relation grâce aux compétences communicatives des TIC.This theoretical article investigates how the concepts of structure and action allow an original approach of the concept of skill in the field of ICT. This approach concerns a search for compatibility between stemming models Technologies which propose the socio-technical structures and those of the Human Sciences who organize the action of the individuals. The theoretical models called by different disciplinary domains (sociology, ethnomethodology, social psychology, linguistic, education, communication and information science give to the concept of skill in ICT a new consistency, more anthropology centred and less technico-practical. They ask the question of the relationship between micro and macro, the relationship of the individual to the group, and also ask the ontological question

  1. Gamma radiography and its technological application; Gammagraphie et techniques annexes

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1962-07-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  2. Lot quality assurance sampling techniques in health surveys in developing countries: advantages and current constraints.

    Science.gov (United States)

    Lanata, C F; Black, R E

    1991-01-01

    Traditional survey methods, which are generally costly and time-consuming, usually provide information at the regional or national level only. The utilization of lot quality assurance sampling (LQAS) methodology, developed in industry for quality control, makes it possible to use small sample sizes when conducting surveys in small geographical or population-based areas (lots). This article describes the practical use of LQAS for conducting health surveys to monitor health programmes in developing countries. Following a brief description of the method, the article explains how to build a sample frame and conduct the sampling to apply LQAS under field conditions. A detailed description of the procedure for selecting a sampling unit to monitor the health programme and a sample size is given. The sampling schemes utilizing LQAS applicable to health surveys, such as simple- and double-sampling schemes, are discussed. The interpretation of the survey results and the planning of subsequent rounds of LQAS surveys are also discussed. When describing the applicability of LQAS in health surveys in developing countries, the article considers current limitations for its use by health planners in charge of health programmes, and suggests ways to overcome these limitations through future research. It is hoped that with increasing attention being given to industrial sampling plans in general, and LQAS in particular, their utilization to monitor health programmes will provide health planners in developing countries with powerful techniques to help them achieve their health programme targets.

  3. Calibrated Phase-Shifting Digital Holographic Microscope Using a Sampling Moiré Technique

    Directory of Open Access Journals (Sweden)

    Peng Xia

    2018-05-01

    Full Text Available A calibrated phase-shifting digital holographic microscope system capable of improving the quality of reconstructed images is proposed. Phase-shifting errors are introduced in phase-shifted holograms for numerous reasons, such as the non-linearity of piezoelectric transducers (PZTs, wavelength fluctuations in lasers, and environmental disturbances, leading to poor-quality reconstructions. In our system, in addition to the camera used to record object information, an extra camera is used to record interferograms, which are used to analyze phase-shifting errors using a sampling Moiré technique. The quality of the reconstructed object images can be improved by the phase-shifting error compensation algorithm. Both the numerical simulation and experiment demonstrate the effectiveness of the proposed system.

  4. k-Means: Random Sampling Procedure

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. k-Means: Random Sampling Procedure. Optimal 1-Mean is. Approximation of Centroid (Inaba et al). S = random sample of size O(1/ ); Centroid of S is a (1+ )-approx centroid of P with constant probability.

  5. Voltammetric technique, a panacea for analytical examination of environmental samples

    International Nuclear Information System (INIS)

    Zahir, E.; Mohiuddin, S.; Naqvi, I.I.

    2012-01-01

    Voltammetric methods for trace metal analysis in environmental samples of marine origin like mangrove, sediments and shrimps are generally recommended. Three different electro-analytical techniques i.e. polarography, anodic stripping voltammetry (ASV) and adsorptive stripping voltammetry (ADSV) have been used. Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ and Mn/sub 2/+ were determined through ASV, Cr/sub 6/+ was analyzed by ADSV and Fe/sub 2/+, Zn/sub 2/+, Ni/sub 2/+ and Co/sub 2/+ were determined through polarography. Out of which pairs of Fe/sub 2/+Zn/sub 2/+ and Ni/sub 2/+Co/sub 2/+ were determined in two separate runs while Cd/sub 2/+, Pb/sub 2/+, Cu/sub 2/+ were analyzed in single run of ASV. Sensitivity and speciation capabilities of voltammetric methods have been employed. Analysis conditions were optimized that includes selection of supporting electrolyte, pH, working electrodes, sweep rate etc. Stripping voltammetry was adopted for analysis at ultra trace levels. Statistical parameters for analytical method development like selectivity factor, interference, repeatability (0.0065-0.130 macro g/g), reproducibility (0.08125-1.625 macro g/g), detection limits (0.032-5.06 macro g/g), limits of quantification (0.081-12.652 macro g/g), sensitivities (5.636-2.15 nA mL macro g-1) etc. were also determined. The percentage recoveries were found in between 95-105% using certified reference materials. Real samples of complex marine environment from Karachi coastline were also analyzed. The standard addition method was employed where any matrix effect was evidenced. (author)

  6. Biopolymers for Sample Collection, Protection, and Preservation

    Science.gov (United States)

    2015-05-19

    knowledge of sample collection from various matrices is crucial. Recovery and preservation of microorganisms prior to analysis are important...Another method for encapsulating bacteria for use in biodegradation of gasoline involves a complex process using gellan gum (Moslemy et al. 2002). Many...use of acacia gum in preserving microorganisms for extended periods of time without refrigeration (Krumnow et al. 2009; Sorokulova et al. 2008, 2012

  7. Spotted owl ecology: theory and methodology—a reply to Rosenberg et al.

    Science.gov (United States)

    A.B. Carey

    1995-01-01

    In their remarks on the study of Spotted Owls (Strix occidentalis) by Carey et al. (1992). Rosenberg et al. (1994) questioned the appropriateness of certain analyses and methods, and specific interpretation of the results. Herein, I respond to the comments of Rosenberg et al. (1994), which are summarized in italics.Sample sizes were nor...

  8. [Amanitine determination as an example of peptide analysis in the biological samples with HPLC-MS technique].

    Science.gov (United States)

    Janus, Tomasz; Jasionowicz, Ewa; Potocka-Banaś, Barbara; Borowiak, Krzysztof

    Routine toxicological analysis is mostly focused on the identification of non-organic and organic, chemically different compounds, but generally with low mass, usually not greater than 500–600 Da. Peptide compounds with atomic mass higher than 900 Da are a specific analytical group. Several dozen of them are highly-toxic substances well known in toxicological practice, for example mushroom toxin and animal venoms. In the paper the authors present an example of alpha-amanitin to explain the analytical problems and different original solutions in identifying peptides in urine samples with the use of the universal LC MS/MS procedure. The analyzed material was urine samples collected from patients with potential mushroom intoxication, routinely diagnosed for amanitin determination. Ultra filtration with centrifuge filter tubes (limited mass cutoff 3 kDa) was used. Filtrate fluid was directly injected on the chromatographic column and analyzed with a mass detector (MS/MS). The separation of peptides as organic, amphoteric compounds from biological material with the use of the SPE technique is well known but requires dedicated, specific columns. The presented paper proved that with the fast and simple ultra filtration technique amanitin can be effectively isolated from urine, and the procedure offers satisfactory sensitivity of detection and eliminates the influence of the biological matrix on analytical results. Another problem which had to be solved was the non-characteristic fragmentation of peptides in the MS/MS procedure providing non-selective chromatograms. It is possible to use higher collision energies in the analytical procedure, which results in more characteristic mass spectres, although it offers lower sensitivity. The ultra filtration technique as a procedure of sample preparation is effective for the isolation of amanitin from the biological matrix. The monitoring of selected mass corresponding to transition with the loss of water molecule offers

  9. Analysis of obsidians by PIXE technique

    International Nuclear Information System (INIS)

    Nuncio Q, A.E.

    1998-01-01

    This work presents the characterization of obsydian samples from different mineral sites in Mexico, undertaken by an Ion Beam Analysis: PIXE (Proton Induced X-ray Emission). As part of an intensive investigation of obsidian in Mesoamerica by anthropologists from Mexico National Institute of Anthropology and History, 818 samples were collected from different volcanic sources in central Mexico for the purpose of establishing a data bank of element concentrations of each source. Part of this collection was analyzed by Neutron activation analysis and most of the important elements concentrations reported. In this work, a non-destructive IBA technique (PIXE) are used to analyze obsydian samples. The application of this technique were carried out at laboratories of the ININ Nuclear Center facilities. The samples consisted of of obsydians from ten different volcanic sources. This pieces were mounted on a sample holder designed for the purpose of exposing each sample to the proton beam. This PIXE analysis was carried out with an ET Tandem Accelerator at the ININ. X-ray spectrometry was carried out with an external beam facility employing a Si(Li) detector set at 52.5 degrees in relation to the target normal (parallel to the beam direction) and 4.2 cm away from the target center. A filter was set in front of the detector, to determine the best attenuation conditions to obtain most of the elements, taking into account that X-ray spectra from obsydians are dominated by intense major elements lines. Thus, a 28 μ m- thick aluminium foil absorber was selected and used to reduce the intensity of the major lines as well as pile-up effects. The mean proton energy was 2.62 MeV, and the beam profile was about 4 mm in diameter. As results were founded elemental concentrations of a set of samples from ten different sources: Altotonga (Veracruz), Penjamo (Guanajuato), Otumba (Mexico), Zinapecuaro (Michoacan), Ucareo (Michoacan), Tres Cabezas (Puebla), Sierra Navajas (Hidalgo), Zaragoza

  10. Microextraction Techniques Coupled to Liquid Chromatography with Mass Spectrometry for the Determination of Organic Micropollutants in Environmental Water Samples

    Directory of Open Access Journals (Sweden)

    Mª Esther Torres Padrón

    2014-07-01

    Full Text Available Until recently, sample preparation was carried out using traditional techniques, such as liquid–liquid extraction (LLE, that use large volumes of organic solvents. Solid-phase extraction (SPE uses much less solvent than LLE, although the volume can still be significant. These preparation methods are expensive, time-consuming and environmentally unfriendly. Recently, a great effort has been made to develop new analytical methodologies able to perform direct analyses using miniaturised equipment, thereby achieving high enrichment factors, minimising solvent consumption and reducing waste. These microextraction techniques improve the performance during sample preparation, particularly in complex water environmental samples, such as wastewaters, surface and ground waters, tap waters, sea and river waters. Liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS and time-of-flight mass spectrometric (TOF/MS techniques can be used when analysing a broad range of organic micropollutants. Before separating and detecting these compounds in environmental samples, the target analytes must be extracted and pre-concentrated to make them detectable. In this work, we review the most recent applications of microextraction preparation techniques in different water environmental matrices to determine organic micropollutants: solid-phase microextraction SPME, in-tube solid-phase microextraction (IT-SPME, stir bar sorptive extraction (SBSE and liquid-phase microextraction (LPME. Several groups of compounds are considered organic micropollutants because these are being released continuously into the environment. Many of these compounds are considered emerging contaminants. These analytes are generally compounds that are not covered by the existing regulations and are now detected more frequently in different environmental compartments. Pharmaceuticals, surfactants, personal care products and other chemicals are considered micropollutants. These

  11. Sample-interpolation timing: an optimized technique for the digital measurement of time of flight for γ rays and neutrons at relatively low sampling rates

    International Nuclear Information System (INIS)

    Aspinall, M D; Joyce, M J; Mackin, R O; Jarrah, Z; Boston, A J; Nolan, P J; Peyton, A J; Hawkes, N P

    2009-01-01

    A unique, digital time pick-off method, known as sample-interpolation timing (SIT) is described. This method demonstrates the possibility of improved timing resolution for the digital measurement of time of flight compared with digital replica-analogue time pick-off methods for signals sampled at relatively low rates. Three analogue timing methods have been replicated in the digital domain (leading-edge, crossover and constant-fraction timing) for pulse data sampled at 8 GSa s −1 . Events arising from the 7 Li(p, n) 7 Be reaction have been detected with an EJ-301 organic liquid scintillator and recorded with a fast digital sampling oscilloscope. Sample-interpolation timing was developed solely for the digital domain and thus performs more efficiently on digital signals compared with analogue time pick-off methods replicated digitally, especially for fast signals that are sampled at rates that current affordable and portable devices can achieve. Sample interpolation can be applied to any analogue timing method replicated digitally and thus also has the potential to exploit the generic capabilities of analogue techniques with the benefits of operating in the digital domain. A threshold in sampling rate with respect to the signal pulse width is observed beyond which further improvements in timing resolution are not attained. This advance is relevant to many applications in which time-of-flight measurement is essential

  12. Cirque du Monde et résilience : interaction entre les enjeux artistiques et les enjeux psychosociaux dans l'action de l'artiste social auprès de jeunes marginalisés

    OpenAIRE

    Gravel-Richard, Pascale

    2008-01-01

    Cette recherche en Études théâtrales se situe dans le domaine des arts populaires et communautaires et dans une perspective pédagogique des arts du cirque. Elle porte davantage sur les aspects relationnels et artistiques que sur les aspects techniques des arts du cirque. Ces derniers sont abordés dans la perspective plus large du développement de la personne. La présente étude fait appel aux sous-champs disciplinaires de la résilience et de la créativité, dans un contexte pédagogique d'éducat...

  13. Using malaise traps to sample ground beetles (Coleoptera: Carabidae).

    Energy Technology Data Exchange (ETDEWEB)

    Ulyshen, Michael D., James L. Hanula, and Scott Horn

    2005-01-01

    Pitfall traps provide an easy and inexpensive way to sample ground-dwelling arthropods (Spence and Niemela 1994; Spence et al. 1997; Abildsnes and Tommeras 2000) and have been used exclusively in many studies of the abundance and diversity of ground beetles (Coleoptera: Carabidae). Despite the popularity of this trapping technique, pitfall traps have many disadvantages. For example, they often fail to collect both small (Spence and Niemela 1994) and trap-shy species (Benest 1989), eventually deplete the local carabid population (Digweed et al. 1995), require a species to be ground-dwelling in order to be captured (Liebherr and Mahar 1979), and produce different results depending on trap diameter and material, type of preservative used, and trap placement (Greenslade 1964; Luff 1975; Work et al. 2002). Further complications arise from seasonal patterns of movement among the beetles themselves (Maelfait and Desender 1990), as well as numerous climatic factors, differences in plant cover, and variable surface conditions (Adis 1979). Because of these limitations, pitfall trap data give an incomplete picture of the carabid community and should be interpreted carefully. Additional methods, such as use of Berlese funnels and litter washing (Spence and Niemela 1994), collection from lights (Usis and MacLean 1998), and deployment of flight intercept devices (Liebherr and Mahar 1979; Paarmann and Stork 1987), should be incorporated in surveys to better ascertain the species composition and relative numbers of ground beetles. Flight intercept devices, like pitfall traps, have the advantage of being easy to use and replicate, but their value to carabid surveys is largely unknown. Here we demonstrate the effectiveness of Malaise traps for sampling ground beetles in a bottomland hardwood forest.

  14. Using malaise traps to sample ground beetles (Coleoptera. Carabidae)

    Energy Technology Data Exchange (ETDEWEB)

    Ulyshen, Michael D. [USDA Forest Service, Savannah River, New Ellenton, SC (United States); Hanula, James L. [USDA Forest Service, Savannah River, New Ellenton, SC (United States); Horn, Scott [USDA Forest Service, Savannah River, New Ellenton, SC (United States)

    2012-04-02

    Pitfall traps provide an easy and inexpensive way to sample ground-dwelling arthropods (Spence and Niemela 1994; Spence et al. 1997; Abildsnes and Tommeras 2000) and have been used exclusively in many studies of the abundance and diversity of ground beetles (Coleoptera: Carabidae). Despite the popularity of this trapping technique, pitfall traps have many disadvantages. For example, they often fail to collect both small (Spence and Niemela 1994) and trap-shy species (Benest 1989), eventually deplete the local carabid population (Digweed et al. 1995), require a species to be ground-dwelling in order to be captured (Liebherr and Mahar 1979), and produce different results depending on trap diameter and material, type of preservative used, and trap placement (Greenslade 1964; Luff 1975; Work et al. 2002). Further complications arise from seasonal patterns of movement among the beetles themselves (Maelfait and Desender 1990), as well as numerous climatic factors, differences in plant cover, and variable surface conditions (Adis 1979). Because of these limitations, pitfall trap data give an incomplete picture of the carabid community and should be interpreted carefully. Additional methods, such as use of Berlese funnels and litter washing (Spence and Niemela 1994), collection from lights (Usis and MacLean 1998), and deployment of flight intercept devices (Liebherr and Mahar 1979; Paarmann and Stork 1987), should be incorporated in surveys to better ascertain the species composition and relative numbers of ground beetles. Flight intercept devices, like pitfall traps, have the advantage of being easy to use and replicate, but their value to carabid surveys is largely unknown. Here we demonstrate the effectiveness of Malaise traps for sampling ground beetles in a bottomland hardwood forest.

  15. MODEL REMEDIASI MISKONSEPSI MATERI RANGKAIAN LISTRIK DENGAN PENDEKATAN SIMULASI PhET

    Directory of Open Access Journals (Sweden)

    Mursalin -

    2013-01-01

    Full Text Available Penelitian ini menggunakan metode eksperimen dengan rancangan “One-Group Pretest-Posttest Design”. Sampel penelitian adalah mahasiswa calon guru fisika yang dipilih dengan teknik random sampling. Instrumen penelitian menggunakan tes pilihan ganda dengan pertanyaan (alasan terbuka disertai dengan model Certainty of Response Index. Tujuan penelitian ini adalah meremediasi miskonsepsi mahasiswa calon guru pada topik rangkaian listrik dengan model simulasi PhET berbantuan lembar kerja. Hasil penelitian pasca pretest diperoleh persentase mahasiswa yang miskonsepsi, terbesar pada konsep: (a arus listrik pada lampu-2 pasca lampu-1 dicabut pada rangkaian paralel (53%, (b beda potensial rangkaian terbuka yang mengandung sumber tegangan (48%, (c gaya gerak listrik dan tegangan jepit (47%, (d tegangan jepit dan arus listrik rangkaian yang mengandung sumber tegangan paralel (37%, dan (e arus listrik pada hubungan singkat (28%. Pasca treatment dengan model simulasi PhET berbantuan lembar kerja, hasil posttest menunjukkan 9 konsep (90% berhasil dipahami dengan baik oleh mahasiswa termasuk yang berstatus menebak konsep, kurang paham konsep, dan miskonsepsi; sedangkan konsep ggl dan tegangan jepit (1 konsep hanya berhasil meminimalkan pemahaman konsep dan miskonsepsi mahasiswa dengan persentase menebak konsep 22%, kurang paham konsep 17%, dan miskonsepsi 11%. This research used the experiment method withOne-Group Pretest-Posttest Design. The research samples were students of physics teacher candidates that selected by random sampling technique. The research instrument used a multiple-choice test accompanied by Certainty of Response Index model. The aims of this research was to remediate misconceptions of students of physics teacher candidates on the electrical circuits topic with the PhET simulation model. The results of this research after pretest showed that the largest percentage of students’ misconceptions was on the concept of (a an

  16. Technique murale picturale

    Directory of Open Access Journals (Sweden)

    Claude Coupry

    2009-09-01

    Full Text Available Après des études remarquables publiées, entre autres, dans Peindre à Auxerre au Moyen Âge, IXe-XIVe siècles, l’étude technique et analytique des peintures murales n’avait pas donné lieu à de nouvelles recherches méthodologiques en dépit des travaux de terrain (Souvigny, Stavelot… où l’archéologie du bâti avait permis des rencontres entre archéologues, historiens de l’art et restaurateurs particulièrement impliqués pour la période qui nous intéresse, de la basse Antiquité au haut Moyen Âge.Ce...

  17. Solving mercury (Hg) speciation in soil samples by synchrotron X-ray microspectroscopic techniques

    International Nuclear Information System (INIS)

    Terzano, Roberto; Santoro, Anna; Spagnuolo, Matteo; Vekemans, Bart; Medici, Luca; Janssens, Koen; Goettlicher, Joerg; Denecke, Melissa A.; Mangold, Stefan; Ruggiero, Pacifico

    2010-01-01

    Direct mercury (Hg) speciation was assessed for soil samples with a Hg concentration ranging from 7 up to 240 mg kg -1 . Hg chemical forms were identified and quantified by sequential extractions and bulk- and micro-analytical techniques exploiting synchrotron generated X-rays. In particular, microspectroscopic techniques such as μ-XRF, μ-XRD and μ-XANES were necessary to solve bulk Hg speciation, in both soil fractions 3 S 2 Cl 2 ), and an amorphous phase containing Hg bound to chlorine and sulfur. The amount of metacinnabar and amorphous phases increased in the fraction <2 μm. No interaction among Hg-species and soil components was observed. All the observed Hg-species originated from the slow weathering of an inert Hg-containing waste material (K106, U.S. EPA) dumped in the area several years ago, which is changing into a relatively more dangerous source of pollution. - Direct mercury (Hg) speciation in chlor-alkali plant contaminated soils enabled the identification of potentially dangerous Hg-S/Cl amorphous species.

  18. Improved abdominal MRI in non-breath-holding children using a radial k-space sampling technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Hyuk; Choi, Young Hun; Cheon, Jung Eun; Lee, So Mi; Cho, Hyun Hae; Kim, Woo Sun; Kim, In One [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Shin, Su Mi [SMG-SNU Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of)

    2015-06-15

    Radial k-space sampling techniques have been shown to reduce motion artifacts in adult abdominal MRI. To compare a T2-weighted radial k-space sampling MRI pulse sequence (BLADE) with standard respiratory-triggered T2-weighted turbo spin echo (TSE) in pediatric abdominal imaging. Axial BLADE and respiratory-triggered turbo spin echo sequences were performed without fat suppression in 32 abdominal MR examinations in children. We retrospectively assessed overall image quality, the presence of respiratory, peristaltic and radial artifact, and lesion conspicuity. We evaluated signal uniformity of each sequence. BLADE showed improved overall image quality (3.35 ± 0.85 vs. 2.59 ± 0.59, P < 0.001), reduced respiratory motion artifact (0.51 ± 0.56 vs. 1.89 ± 0.68, P < 0.001), and improved lesion conspicuity (3.54 ± 0.88 vs. 2.92 ± 0.77, P = 0.006) compared to respiratory triggering turbo spin-echo (TSE) sequences. The bowel motion artifact scores were similar for both sequences (1.65 ± 0.77 vs. 1.79 ± 0.74, P = 0.691). BLADE introduced a radial artifact that was not observed on the respiratory triggering-TSE images (1.10 ± 0.85 vs. 0, P < 0.001). BLADE was associated with diminished signal variation compared with respiratory triggering-TSE in the liver, spleen and air (P < 0.001). The radial k-space sampling technique improved the quality and reduced respiratory motion artifacts in young children compared with conventional respiratory-triggered turbo spin-echo sequences. (orig.)

  19. An evaluation of sampling methods and supporting techniques for tackling lead in drinking water in Aberta Province

    Science.gov (United States)

    A collaborative project commenced in August 2013 with the aim of demonstrating a range of techniques that can be used in tackling the problems of lead in drinking water. The main project was completed in March 2014, with supplementary sampling exercises in mid-2014. It involved t...

  20. A comparative study of 232Th and 238U activity estimation in soil samples by gamma spectrometry and Neutron Activation Analysis (NAA) technique

    International Nuclear Information System (INIS)

    Rekha, A.K.; Anilkumar, S.; Narayani, K.; Babu, D.A.R.

    2012-01-01

    Radioactivity in the environment is mainly due to the naturally occurring radionuclides like uranium, thorium with their daughter products and potassium. Even though Gamma spectrometry is the most commonly used non destructive method for the quantification of these naturally occurring radionuclides, Neutron Activation Analysis (NAA), a well established analytical technique, can also be used. But the NAA technique is a time consuming process and needs proper standards, proper sample preparation etc. In this paper, the 232 Th and 238 U activity estimated using gamma ray spectrometry and NAA technique are compared. In the case of direct gamma spectrometry method, the samples were analysed after sealing in a 250 ml container. Whereas for the NAA, about 300 mg of each sample, after irradiation were subjected to gamma spectrometry. The 238 U and 232 Th activities (in Bq/kg) in samples were estimated after the proper efficiency correction and were compared. The estimated activities by these two methods are in good agreement. The variation in 238 U and 232 Th activity values are within ± 15% which are acceptable for environmental samples

  1. Elemental analysis of two Egyptian iron ores and produced industrial iron samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Sroor, A.; Abdel-Basset, N.; Abdel-Haleem, A.S.; Hassan, A.M.

    2001-01-01

    Elemental analysis of two iron ores and initial industrial iron production prepared by the Egyptian Iron and Steel Company of Helwan near Cairo were performed by the instrumental neutron activation analysis technique. Five samples of each type were irradiated for 48 h in a thermal neutron flux of 4x10 12 n/cm 2 s in the first Egyptian research reactor ET-RR-1. Also, the Pneumatic Irradiation Rabbit System (PIRS), attached to the reactor ET-RR-1 in Inshass, was used to measure short-life elements. The γ-ray spectra were obtained with a hyper pure germanium detection system. The concentration percentage values of major, minor and trace elements are presented. Implications of the elemental concentration values obtained are presented

  2. Facilitation de la collaboration et de l'échange d'information au sein ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    L'un des principaux objectifs du programme telecentre.org du CRDI est de soutenir les télécentres et leur milieu partout dans le monde. Ce projet permettra à telecentre.org de mener une enquête sur l'utilisation des techniques de collaboration sociale que rendent possibles les nouveaux outils et services du Web 2.0.

  3. Métacognition et formation des adultes

    Directory of Open Access Journals (Sweden)

    Arnim Kaiser

    2011-01-01

    Full Text Available Actuellement, il existe de nombreuses études empiriques abordant la relation entre la métacognition et les analyses théoriques correspondantes, relation concernant plus particulièrement l’apprentissage par auto-régulation. En revanche, trois aspects importants demeurent, jusqu’à présent, quelque peu exclus : les études intègrent rarement les adultes dans la population étudiée, elles se consacrent très rarement à la mise en œuvre d’approches à orientation métacognitive dans un champ didactique concret et écartent en grande partie la question de savoir de quelles compétences doivent disposer les enseignants au sein de la formation continue si l’on veut que la métacognition devienne partie intégrante de leur conception de l’enseignement et de l’apprentissage. La présente contribution se propose donc de combler quelques unes de ces lacunes de manière ciblée en s’appuyant sur les résultats de différents projets de recherche dans lesquels la métacognition joue un rôle essentiel.Invariably, thinking is concomitant with metacognition. Against the background of this thesis, the article pursues a number of theoretical as well as empirical questions which arise in this context. What, precisely, is to be understood under the term metacognition? Which are the constitutive elements of the definition? What does an explicit metacognitive orientation consist of? Using a primarily empirical approach, more in-depth questions are looked into: Among adult learners, what is the distribution of developed versus less developed metacognitive orientations in the random samples available to us? Which are the personality variables that favor the acquisition and explicit application of metacognitive accesses? Does a developed metacognitive attitude have an effect on learning success, and if so, what weight does it have? The last-mentioned questions were clarified in two research projects on organized continued education of several

  4. Probabilistic techniques using Monte Carlo sampling for multi- component system diagnostics

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Lee, J.C.; Akcasu, A.Z.

    1995-01-01

    We outline the structure of a new approach at multi-component system fault diagnostics which utilizes detailed system simulation models, uncertain system observation data, statistical knowledge of system parameters, expert opinion, and component reliability data in an effort to identify incipient component performance degradations of arbitrary number and magnitude. The technique involves the use of multiple adaptive Kalman filters for fault estimation, the results of which are screened using standard hypothesis testing procedures to define a set of component events that could have transpired. Latin Hypercube sample each of these feasible component events in terms of uncertain component reliability data and filter estimates. The capabilities of the procedure are demonstrated through the analysis of a simulated small magnitude binary component fault in a boiling water reactor balance of plant. The results show that the procedure has the potential to be a very effective tool for incipient component fault diagnosis

  5. Exploring an optimal wavelet-based filter for cryo-ET imaging.

    Science.gov (United States)

    Huang, Xinrui; Li, Sha; Gao, Song

    2018-02-07

    Cryo-electron tomography (cryo-ET) is one of the most advanced technologies for the in situ visualization of molecular machines by producing three-dimensional (3D) biological structures. However, cryo-ET imaging has two serious disadvantages-low dose and low image contrast-which result in high-resolution information being obscured by noise and image quality being degraded, and this causes errors in biological interpretation. The purpose of this research is to explore an optimal wavelet denoising technique to reduce noise in cryo-ET images. We perform tests using simulation data and design a filter using the optimum selected wavelet parameters (three-level decomposition, level-1 zeroed out, subband-dependent threshold, a soft-thresholding and spline-based discrete dyadic wavelet transform (DDWT)), which we call a modified wavelet shrinkage filter; this filter is suitable for noisy cryo-ET data. When testing using real cryo-ET experiment data, higher quality images and more accurate measures of a biological structure can be obtained with the modified wavelet shrinkage filter processing compared with conventional processing. Because the proposed method provides an inherent advantage when dealing with cryo-ET images, it can therefore extend the current state-of-the-art technology in assisting all aspects of cryo-ET studies: visualization, reconstruction, structural analysis, and interpretation.

  6. Le recours aux modeles dans l'enseignement de la biologie au secondaire : Conceptions d'enseignantes et d'enseignants et modes d'utilisation

    Science.gov (United States)

    Varlet, Madeleine

    Le recours aux modeles et a la modelisation est mentionne dans la documentation scientifique comme un moyen de favoriser la mise en oeuvre de pratiques d'enseignement-apprentissage constructivistes pour pallier les difficultes d'apprentissage en sciences. L'etude prealable du rapport des enseignantes et des enseignants aux modeles et a la modelisation est alors pertinente pour comprendre leurs pratiques d'enseignement et identifier des elements dont la prise en compte dans les formations initiale et disciplinaire peut contribuer au developpement d'un enseignement constructiviste des sciences. Plusieurs recherches ont porte sur ces conceptions sans faire de distinction selon les matieres enseignees, telles la physique, la chimie ou la biologie, alors que les modeles ne sont pas forcement utilises ou compris de la meme maniere dans ces differentes disciplines. Notre recherche s'est interessee aux conceptions d'enseignantes et d'enseignants de biologie au secondaire au sujet des modeles scientifiques, de quelques formes de representations de ces modeles ainsi que de leurs modes d'utilisation en classe. Les resultats, que nous avons obtenus au moyen d'une serie d'entrevues semi-dirigees, indiquent que globalement leurs conceptions au sujet des modeles sont compatibles avec celle scientifiquement admise, mais varient quant aux formes de representations des modeles. L'examen de ces conceptions temoigne d'une connaissance limitee des modeles et variable selon la matiere enseignee. Le niveau d'etudes, la formation prealable, l'experience en enseignement et un possible cloisonnement des matieres pourraient expliquer les differentes conceptions identifiees. En outre, des difficultes temporelles, conceptuelles et techniques peuvent freiner leurs tentatives de modelisation avec les eleves. Toutefois, nos resultats accreditent l'hypothese que les conceptions des enseignantes et des enseignants eux-memes au sujet des modeles, de leurs formes de representation et de leur approche

  7. Use of a multigrid technique to study effects of limited sampling of heterogeneity on transport prediction

    International Nuclear Information System (INIS)

    Cole, C.R.; Foote, H.P.

    1987-02-01

    Reliable ground water transport prediction requires accurate spatial and temporal characterization of a hydrogeologic system. However, cost constraints and the desire to maintain site integrity by minimizing drilling can restrict the amount of spatial sampling that can be obtained to resolve the flow parameter variability associated with heterogeneities. This study quantifies the errors in subsurface transport predictions resulting from incomplete characterization of hydraulic conductivity heterogeneity. A multigrid technique was used to simulate two-dimensional flow velocity fields with high resolution. To obtain these velocity fields, the finite difference code MGRID, which implements a multigrid solution technique, was applied to compute stream functions on a 256-by-256 grid for a variety of hypothetical systems having detailed distributions of hydraulic conductivity. Spatial variability in hydraulic conductivity distributions was characterized by the components in the spectrum of spatial frequencies. A low-pass spatial filtering technique was applied to the base case hydraulic conductivity distribution to produce a data set with lower spatial frequency content. Arrival time curves were then calculated for filtered hydraulic conductivity distribution and compared to base case results to judge the relative importance of the higher spatial frequency components. Results indicate a progression from multimode to single-mode arrival time curves as the number and extent of distinct flow pathways are reduced by low-pass filtering. This relationship between transport predictions and spatial frequencies was used to judge the consequences of sampling the hydraulic conductivity with reduced spatial resolution. 22 refs., 17 figs

  8. Physique appliquée à l’exposition externe dosimétrie et radioprotection

    CERN Document Server

    Antoni, Rodolphe

    2013-01-01

    Cet ouvrage fait la synthèse de nombreuses années d'expériences en dosimétrie et techniques de protection contre l’exposition externe, aussi bien dans le domaine industriel que médical. Il rappelle les concepts physiques de base puis propose un certain nombre d'outils d’évaluation des nuisances radiologiques, et les moyens de s'en prémunir, en détaillant notamment les techniques de calcul pour des blindages appropriés. Le premier chapitre traite de la définition des grandeurs radiométriques et dosimétriques fondamentales. Il permet d’aborder au chapitre 2 la question de l'interaction rayonnement-matière sous un angle dédié au dépôt de la dose dans les tissus biologiques. Le troisième chapitre définit quant à lui les grandeurs de protection et les grandeurs opérationnelles liées à la radioprotection. Dans les deux chapitres suivants, l’accent a été mis sur la définition des risques et contre-mesures associées (i.e. protections biologiques) inhérents aux sources de rayonnemen...

  9. Manipulation of biological samples using micro and nano techniques

    DEFF Research Database (Denmark)

    Castillo, Jaime; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    to their natural structure. Thanks to the advances in micro- and nanofabrication during the last decades several manipulation techniques offer us the possibility to image, characterize and manipulate biological material in a controlled way. Using these techniques the integration of biomaterials with remarkable...

  10. Les référentiels du CHSCT Sécurité et amélioration des conditions de travail

    CERN Document Server

    2014-01-01

    5 Normes phares : - NF X35-103 (juin 2013) Ergonomie - Principes d'ergonomie applicables à l'éclairage des lieux de travail - NF X08-070 (juin 2013) Informations et instructions de sécurité - Consignes et instructions, plans d'évacuation, plans d'intervention, plans et documentation technique de sécurité - NF X35-109 (octobre 2011) Ergonomie - Manutention manuelle de charge pour soulever, déplacer et pousser/tirer - Méthodologie d'analyse et valeurs seuils - XP X43-269 (avril 2012) Qualité de l'air - Air des lieux de travail - Prélèvement sur filtre à membrane pour la détermination de la concentration en nombre de fibres par les techniques de microscopie : MOCP, MEBA et META - Comptage par MOCP - NF EN ISO 9612 (mai 2009) Acoustique - Détermination de l'exposition au bruit en milieu de travail - Méthode d'expertise Objectif : protection maximale ! Réduire et éliminer les accidents de travail.

  11. Development of analytical techniques for water and environmental samples (2)

    Energy Technology Data Exchange (ETDEWEB)

    Eum, Chul Hun; Jeon, Chi Wan; Jung, Kang Sup; Song, Kyung Sun; Kim, Sang Yeon [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The purpose of this study is to develop new analytical methods with good detection limit for toxic inorganic and organic compounds. The analyses of CN, organic acids, particulate materials in environmental samples have been done using several methods such as Ion Chromatography, SPE, SPME, GC/MS, GC/FID, SPLITT (split-flow thin cell fractionation) during the second year of this project. Advantage and disadvantage of several distillation method (by KS, JIS, EPA) for CN analysis in wastewater were investigated. As the results, we proposed new distillation apparatus for CN analysis, which was proved to be simpler, faster and to get better recovery than conventional apparatus. And ion chromatograph/pulsed amperometric detector (IC/PAD) system instead of colorimetry for CN detection was setup to solve matrix interference. And SPE(solid phase extraction) and SPME (solid phase micro extraction) as liquid-solid extraction technique were applied to the analysis of phenols in wastewater. Optimum experimental conditions and factors influencing analytical results were determined. From these results, It could be concluded that C{sub 18} cartridge and polystyrene-divinylbenzene disk in SPE method, polyacrylate fiber in SPME were proper solid phase adsorbent for phenol. Optimum conditions to analyze phenol derivatives simultaneously were established. Also, Continuous SPLITT (Split-flow thin cell) Fractionation (CSF) is a new preparative separation technique that is useful for fractionation of particulate and macromolecular materials. CSF is carried out in a thin ribbon-like channel equipped with two splitters at both inlet and outlet of the channel. In this work, we set up a new CSF system, and tested using polystyrene latex standard particles. And then we fractionated particles contained in air and underground water based on their sedimentation coefficients using CSF. (author). 27 refs., 13 tabs., 31 figs.

  12. Characterization technique for detection of atom-size crystalline defects and strains using two-dimensional fast-Fourier-transform sampling Moiré method

    Science.gov (United States)

    Kodera, Masako; Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi; Yoshioka, Akira; Sugiyama, Toru; Hamamoto, Takeshi; Miyashita, Naoto

    2018-04-01

    Recently, we have developed a two-dimensional (2D) fast-Fourier-transform (FFT) sampling Moiré technique to visually and quantitatively determine the locations of minute defects in a transmission electron microscopy (TEM) image. We applied this technique for defect detection with GaN high electron mobility transistor (HEMT) devices, and successfully and clearly visualized atom-size defects in AlGaN/GaN crystalline structures. The defect density obtained in the AlGaN/GaN structures is ∼1013 counts/cm2. In addition, we have successfully confirmed that the distribution and number of defects closely depend on the process conditions. Thus, this technique is quite useful for a device development. Moreover, the strain fields in an AlGaN/GaN crystal were effectively calculated with nm-scale resolution using this method. We also demonstrated that this sampling Moiré technique is applicable to silicon devices, which have principal directions different from those of AlGaN/GaN crystals. As a result, we believe that the 2D FFT sampling Moiré method has great potential applications to the discovery of new as yet unknown phenomena occurring between the characteristics of a crystalline material and device performance.

  13. Comparison of sampling techniques for Bayesian parameter estimation

    Science.gov (United States)

    Allison, Rupert; Dunkley, Joanna

    2014-02-01

    The posterior probability distribution for a set of model parameters encodes all that the data have to tell us in the context of a given model; it is the fundamental quantity for Bayesian parameter estimation. In order to infer the posterior probability distribution we have to decide how to explore parameter space. Here we compare three prescriptions for how parameter space is navigated, discussing their relative merits. We consider Metropolis-Hasting sampling, nested sampling and affine-invariant ensemble Markov chain Monte Carlo (MCMC) sampling. We focus on their performance on toy-model Gaussian likelihoods and on a real-world cosmological data set. We outline the sampling algorithms themselves and elaborate on performance diagnostics such as convergence time, scope for parallelization, dimensional scaling, requisite tunings and suitability for non-Gaussian distributions. We find that nested sampling delivers high-fidelity estimates for posterior statistics at low computational cost, and should be adopted in favour of Metropolis-Hastings in many cases. Affine-invariant MCMC is competitive when computing clusters can be utilized for massive parallelization. Affine-invariant MCMC and existing extensions to nested sampling naturally probe multimodal and curving distributions.

  14. Use of the electrodeposition technique in the preparation of samples of 237Np and its determination by alpha spectrometry

    International Nuclear Information System (INIS)

    Mertzig, W.; Matsuda, H.T.; Araujo, B.F. de; Araujo, J.A. de.

    1981-05-01

    The electroplating technique to prepare 237 Np source and its determination by alpha spectrometry is presented. The samples were prepared using a lucite-eletrolitic cell manufactured at IPEN, specially to trace amounts of actinides. A polished brass disk coated with Ni film has been used as cathodo and a fixed Pt wire as anode. The electroplated samples were alpha counted using a surface barrier detector. The optimum conditions to obtain the quantitative deposition of 237 Np have been achieved by studying the effects of some parameters as current density, pH and concentration of eletrolitic solution and time of eletrodeposition, using a carrier technique. After preliminary purification, the method is applied to control trace amounts of 237 Np in the Purex process solutions. (Author) [pt

  15. Mécanique fondements et applications : avec 300 exercices et problèmes résolus

    CERN Document Server

    Pérez, José-Philippe

    1997-01-01

    Cet ouvrage fait partie de ceux que l'on acquiert dès le début de ses études et que l'on conserve comme ouvrage de référence. Ce cours rassemble en un seul volume les notions fondamentales de la mécanique. Il est construit en 32 chapitres volontairement assez courts mais très pédagogiques, illustrés d'environ 300 exercices et problèmes corrigés. La première partie concerne la mécanique du point matériel soumis à des forces. La seconde présente la mécanique des N points matériels en interaction. La troisième, plus technique, développe la mécanique générale des solides indéformables. Enfin la quatrième porte sur les bases de la mécanique des fluides.

  16. Rock-Eval 6 Applications in Hydrocarbon Exploration, Production, and Soil Contamination Studies Les applications de Rock-Eval 6 dans l'exploration et la production des hydrocarbures, et dans les études de contamination des sols

    Directory of Open Access Journals (Sweden)

    Lafargue E.

    2006-12-01

    Full Text Available Successful petroleum exploration relies on detailed analysis of the petroleum system in a given area. Identification of potential source rocks, their maturity and kinetic parameters, and their regional distribution are best accomplished by rapid screening of rock samples (cores and/or cuttings using the Rock-Eval apparatus. The technique has been routinely used for about fifteen years and has become a standard tool for hydrocarbon exploration. This paper describes how the new functions of the latest version of Rock-Eval (Rock-Eval 6 have expanded applications of the method in petroleum geoscience. Examples of new applications are illustrated for source rock characterization, reservoir geochemistry, and environmental studies, including quantification. Le succès d'une exploration pétrolière repose sur l'analyse détaillée du système pétrolier dans une zone donnée. L'identification des roches mères potentielles, la détermination de leur maturité, de leurs paramètres cinétiques et de leur répartition sont réalisées au mieux à partir d'examens rapides d'échantillons de roches (carottes ou déblais au moyen de la pyrolyse Rock-Eval. Cette technique a été utilisée en routine pendant une quinzaine d'années et elle est devenue un outil standard pour l'exploration des hydrocarbures. Cet article décrit comment les nouvelles fonctionnalités de la dernière version de l'appareil Rock-Eval (Rock-Eval 6 ont permis une expansion des applications de la méthode en géosciences pétrolières. Des exemples d'applications nouvelles sont illustrés dans les domaines de la caractérisation des roches mères, de la géochimie de réservoir et des études environnementales incluant la quantification et la description des hydrocarbures dans des sols contaminés.

  17. [A comparison of convenience sampling and purposive sampling].

    Science.gov (United States)

    Suen, Lee-Jen Wu; Huang, Hui-Man; Lee, Hao-Hsien

    2014-06-01

    Convenience sampling and purposive sampling are two different sampling methods. This article first explains sampling terms such as target population, accessible population, simple random sampling, intended sample, actual sample, and statistical power analysis. These terms are then used to explain the difference between "convenience sampling" and purposive sampling." Convenience sampling is a non-probabilistic sampling technique applicable to qualitative or quantitative studies, although it is most frequently used in quantitative studies. In convenience samples, subjects more readily accessible to the researcher are more likely to be included. Thus, in quantitative studies, opportunity to participate is not equal for all qualified individuals in the target population and study results are not necessarily generalizable to this population. As in all quantitative studies, increasing the sample size increases the statistical power of the convenience sample. In contrast, purposive sampling is typically used in qualitative studies. Researchers who use this technique carefully select subjects based on study purpose with the expectation that each participant will provide unique and rich information of value to the study. As a result, members of the accessible population are not interchangeable and sample size is determined by data saturation not by statistical power analysis.

  18. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  19. Analysis of boron utilization in sample preparation for microorganisms detection by neutron radiography technique

    International Nuclear Information System (INIS)

    Wacha, Reinaldo; Crispim, Verginia R.

    2000-01-01

    The neutron radiography technique applied to the microorganisms detection is the study of a new and faster alternative for diagnosis of infectious means. This work presents the parameters and the effects involved in the use of the boron as a conversion agent, that convert neutrons in a particles, capable ones of generating latent tracks in a solid state nuclear tracks detector, CR-39. The collected samples are doped with the boron by the incubation method, propitiating an interaction microorganisms/boron, that will guarantee the identification of the images of those microorganisms, through your morphology. (author)

  20. Sciences et éthique | conférence d'Axel Kahn | 20 novembre

    CERN Multimedia

    2012-01-01

    Mardi 20 novembre 2012 à 20h30 Globe de la science et de l'innovation Route de Meyrin, 1211 Genève En français Tout public - entrée libre Nombre de places limité - réservation indispensable Réservation au +41 22 767 76 76 Parce que « le savoir est pouvoir pour l'homme de se rendre comme maître et possesseur de la nature », nous sommes collectivement de plus en plus savant et de plus en plus puissant. Reste à ce que notre sagesse nous conduise à utiliser nos pouvoirs au profit des personnes, et non à leur détriment, en d'autres termes, à ce que le progrès scientifique constitue une chance et non une menace. Pour qu'il en soit ainsi, il importe de non seulement développer les sciences et les techniques mais aussi de leur assigner des objectifs au centre desquels résident l'...

  1. L’apprentissage de la coopération intercommunale : modalités et instruments

    OpenAIRE

    Loubet, Lilian

    2012-01-01

    Le développement de l’intercommunalité donne lieu à des recompositions territoriales et gouvernementales majeures. Les élus se confrontent alors à l’exercice complexe de la coopération et à la définition d’un projet territorial. Il s’agira d’étudier la coopération intercommunale au regard des apprentissages (techniques, politiques et territoriaux) opérés par les maires et de concentrer l’analyse sur les « instruments » de ce processus. Ce propos est illustré par l’étude de l’agglomération tou...

  2. Enjeux et pratiques documentaires en conservation-restauration, perspectives pour la recherche 

    Directory of Open Access Journals (Sweden)

    Marie-Hélène Breuil

    2010-11-01

    Full Text Available IntroductionConsacrées à la documentation des œuvres, ces deux journées d’étude qui se sont tenues les 14 et 15 octobre 2010 comportaient quatre sessions : définition, production, gestion et utilisation. Elles ont permis de faire le point et d’échanger sur les outils techniques, les contenus, l’accès ainsi que la conservation de cette documentation. Dans son introduction, Thierry Lalot, directeur du CRPB (Université Paris 1, a souligné la volonté d’ouvrir des perspectives pour la recherche e...

  3. Etude des melanges co-continus d'acide polylactique et d'amidon thermoplastique (PLA/TPS)

    Science.gov (United States)

    Chavez Garcia, Maria Graciela

    Les melanges co-continus sont des melanges polymeriques ou chaque composant se trouve dans une phase continue. Pour cette raison, les caracteristiques de chacun des composants se combinent et il en resulte un materiau avec une morphologie et des proprietes particulieres. L'acide polylactique (PLA) et l'amidon thermoplastique (TPS) sont des biopolymeres qui proviennent de ressources renouvelables et qui sont biodegradables. Dans ce projet, differents melanges de PLA et TPS a une haute concentration de TPS ont ete prepares dans une extrudeuse bi-vis afin de generer des structures co-continues. Grace a la technique de lixiviation selective, le TPS est enleve pour creer une structure poreuse de PLA qui a pu etre analysee au moyen de la microtomographie R-X et de la microscopie electronique a balayage MEB. L'analyse des images 2D et 3D confirme la presence de la structure co-continue dans les melanges dont la concentration en TPS. se situe entre 66% et 80%. L'effet de deux plastifiants, le glycerol seul et le melange de glycerol et de sorbitol, dans la formulation de TPS est etudie dans ce travail. De plus, nous avons evalue l'effet du PLA greffe a l'anhydride maleique (PLAg) en tant que compatibilisant. On a trouve que la phase de TPS obtenue avec le glycerol est plus grande. L'effet de recuit sur la taille de phases est aussi analyse. Grace aux memes techniques d'analyse, on a etudie l'effet du procede de moulage par injection sur la morphologie. On a constate que les pieces injectees presentent une microstructure heterogene et differente entre la surface et le centre de la piece. Pres de la surface, une peau plus riche en PLA est presente et les phases de TPS y sont allongees sous forme de lamelles. Plus au centre de la piece, une morphologie plus cellulaire est observee pour chaque phase continue. L'effet des formulations sur les proprietes mecaniques a aussi ete etudie. Les pieces injectees dont la concentration de TPS est plus grande presentent une moindre

  4. De l'auteur à l'utilisateur : transmettre l'attribution et la citation

    OpenAIRE

    Dulong de Rosnay, Melanie

    2012-01-01

    Citer l'auteur est une norme sociale qui dépasse les obligations juridiques et permet de comprendre qui a émis un document ou l'a modifié, de distinguer oeuvre originale, reprise, commentaire ou transformation et ainsi d'inférer la valeur ou la réputation d'une information. Ces questions déjà présentes dans la culture papier sont multipliées avec les pratiques créatives numériques, comme l'échantillonnage ou le sampling et le remix artistique et l'écriture collaborative. Les étapes et facette...

  5. Comparison of Two Surface Contamination Sampling Techniques Conducted for the Characterization of Two Pajarito Site Manhattan Project National Historic Park Properties

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Tammy Ann [Montana Tech of the Univ. of Montana, Butte, MT (United States); Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-29

    Technical Area-18 (TA-18), also known as Pajarito Site, is located on Los Alamos National Laboratory property and has historic buildings that will be included in the Manhattan Project National Historic Park. Characterization studies of metal contamination were needed in two of the four buildings that are on the historic registry in this area, a “battleship” bunker building (TA-18-0002) and the Pond cabin (TA-18-0029). However, these two buildings have been exposed to the elements, are decades old, and have porous and rough surfaces (wood and concrete). Due to these conditions, it was questioned whether standard wipe sampling would be adequate to detect surface dust metal contamination in these buildings. Thus, micro-vacuum and surface wet wipe sampling techniques were performed side-by-side at both buildings and results were compared statistically. A two-tail paired t-test revealed that the micro-vacuum and wet wipe techniques were statistically different for both buildings. Further mathematical analysis revealed that the wet wipe technique picked up more metals from the surface than the microvacuum technique. Wet wipes revealed concentrations of beryllium and lead above internal housekeeping limits; however, using an yttrium normalization method with linear regression analysis between beryllium and yttrium revealed a correlation indicating that the beryllium levels were likely due to background and not operational contamination. PPE and administrative controls were implemented for National Park Service (NPS) and Department of Energy (DOE) tours as a result of this study. Overall, this study indicates that the micro-vacuum technique may not be an efficient technique to sample for metal dust contamination.

  6. Extraction, fractionnement et concentration des huiles marines

    Directory of Open Access Journals (Sweden)

    Linder Michel

    2004-03-01

    Full Text Available Les huiles marines représentent des sources potentielles d’acides gras polyinsaturés (AGPI dont les implications au niveau de la nutrition et de la santé sont avérées. Ces molécules sont extraites à partir de poissons, algues ou co-produits de la filière halieutique par des procédés de cuisson-pression, en présence de solvants ou par des techniques enzymatiques beaucoup moins drastiques. Des fractions plus ou moins purifiées en AGPI sont obtenues par cristallisation à froid, en présence de solvants organiques, complexation avec de l’urée, distillation moléculaire ou extraction par fluide supercritique. L’utilisation de lipases stéréospécifiques dans des procédés d’hydrolyse et d’estérification conduit à une diversité de molécules d’acylglycérols riches en AGPI trouvant de nombreuses applications dans le domaine de l’agroalimentaire et de la santé.

  7. Diurnal activity of four species of thrips (Thysanoptera: Thripidae) and efficiencies of three nondestructive sampling techniques for thrips in mango inflorescences.

    Science.gov (United States)

    Aliakbarpour, H; Rawi, Che Salmah Md

    2010-06-01

    Thrips cause considerable economic loss to mango, Mangifera indica L., in Penang, Malaysia. Three nondestructive sampling techniques--shaking mango panicles over a moist plastic tray, washing the panicles with ethanol, and immobilization of thrips by using CO2--were evaluated for their precision to determine the most effective technique to capture mango flower thrips (Thysanoptera: Thripidae) in an orchard located at Balik Pulau, Penang, Malaysia, during two flowering seasons from December 2008 to February 2009 and from August to September 2009. The efficiency of each of the three sampling techniques was compared with absolute population counts on whole panicles as a reference. Diurnal flight activity of thrips species was assessed using yellow sticky traps. All three sampling methods and sticky traps were used at two hourly intervals from 0800 to 1800 hours to get insight into diurnal periodicity of thrips abundance in the orchard. Based on pooled data for the two seasons, the CO2 method was the most efficient procedure extracting 80.7% adults and 74.5% larvae. The CO2 method had the lowest relative variation and was the most accurate procedure compared with the absolute method as shown by regression analysis. All collection techniques showed that the numbers of all thrips species in mango panicles increased after 0800 hours, reaching a peak between 1200 and 1400 hours. Adults thrips captured on the sticky traps were the most abundant between 0800-1000 and 1400-1600 hours. According to results of this study, the CO2 method is recommended for sampling of thrips in the field. It is a nondestructive sampling procedure that neither damages flowers nor diminishes fruit production. Management of thrips populations in mango orchards with insecticides would be more effectively carried out during their peak population abundance on the flower panicles at midday to 1400 hours.

  8. Importance sampling techniques and treatment of electron transport in MCNP 4A

    International Nuclear Information System (INIS)

    Ueki, K.

    1994-01-01

    The continuous energy Monte Carlo code MCNP was developed by the Radiation Transport Group at Los Alamos National Laboratory and the MCNP 4A version is available, now. The MCNP 4A is able to do the coupled neutron-secondary gamma-ray-electron-bremsstrahlung calculation. The calculated results, such as energy spectra, tally fluctuation chart, and geometrical input data can be displayed by using a work station. The document of the MCNP 4A code has no description on the subroutines, except few ones of 'SOURCE', 'TALLYX'. However, when we want to improve the MCNP Monte Carlo sampling techniques to get more accuracy or efficiency results for some problems, some subroutines are required or needed to revised. Three subroutines have been revised and built in the MCNP 4A code. (author)

  9. Gestion Technique Centralisée en Génie Climatique

    CERN Document Server

    Pepinster, P

    1999-01-01

    Il y a une quinzaine d'années, la Division ST a introduit sur les équipements de chauffage et de climatisation du CERN, des systèmes de contrôle locaux à microprocesseur en lieu et place des chaînes de régulation devenues obsolètes. Adoptée dans une volonté d'évolution technologique et dans une démarche de rationalisation des dépenses d'énergie, cette technique s'est répandue sur les différents sites du Laboratoire au fil des années. Depuis les applications de confort climatique dans les bâtiments tertiaires, jusqu'au conditionnement d'air des accélérateurs et des expériences, en passant par l'autocontrôle des chaufferies centrales, ces 'Unités de Traitement Locales' (UTL) sont aujourd'hui interconnectées en un système de Gestion Technique Centralisée d'environ 140 sous-stations. L'objet du document est de présenter la structure actuelle de ce système GTC, d'en montrer les possibilités et l'intérêt dans son exploitation quotidienne au CERN, et d'aborder ses évolutions futures.

  10. Determination of elemental in soil samples from Gebeng area using NAA technique

    International Nuclear Information System (INIS)

    Md Suhaimi Elias; Wo, Y.M.; Mohd Suhaimi Hamzah

    2016-01-01

    Rapid development and urbanization will increase number of residence and industrial area. Without proper management and control of pollution, these will give an adverse effect to environment and human life. The objective of this study to identify and quantify key contaminants into the environment of the Gebeng area as a result of industrial and human activities. Gebeng area was gazetted as one of the industrial estate in Pahang state. Assessment of elemental pollution in soil of Gebeng area base on level of concentration, enrichment factor and geo-accumulation index. The enrichment factors (EFs) were determined by the elemental rationing method, whilst the geo-accumulation index (I_g_e_o) by comparing of current to continental crustal average concentration of element. Twenty-seven of soil samples were collected from Gebeng area. Soil samples were analysed by using Neutron Activation Analyses (NAA) technique. The obtained data showed higher concentration of iron (Fe) due to abundance in soil compared to other elements. The results of enrichment factor showed that Gebeng area have enrich with elements of As, Br, Hf, Sb, Th and U. Base on the geo-accumulation index (I_g_e_o) classification, the soil quality of Gebeng area can be classified as class 0, (uncontaminated) to Class 3, (moderately to heavily contaminated). (author)

  11. Application of the spectrometric and radiochemical techniques in analyzing environmental samples from the Bulgarian Black Sea region

    International Nuclear Information System (INIS)

    Veleva, B.S.; Mungov, G.; Galabov, N.; Kolarova, M.; Guenchev, T.

    1999-01-01

    Development of the appropriate methods and techniques for marine and atmospheric radioactivity measurements in the NIMH-BAS during the last 5 years is presented. Approaches for pre-concentration of the radionuclides from the atmosphere and sea water samples followed with reliable radiochemical methods for radionuclides separation and low level counting are discussed. Dissolved radiocesium concentrations measured in a period of time starting in 1993 show some decrease with years and spatial variations probably due to the hydrophysical features of the sampling sides - the lower measured concentrations during 1995 and 1998 correspond to the lower salinity. Application of the radiochemical separation of Plutonium, Thorium, 90 Sr and Americium on the samples from the Bulgarian Black Sea coastal region is reported. (author)

  12. Techniques for the measurement of the contamination of air; Technique de mesure de la contamination de l'air

    Energy Technology Data Exchange (ETDEWEB)

    Labeyrie, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    This lecture has been given at the International Symposium of Riso 1959. Methods for measuring radioactive content of the atmosphere are described, and main results found at Saclay are given, for the following contaminants: Rn, Tn and their daughter, H-3, C-14, A-41, Kr-85, I-131, and fission products as a whole. (author) [French] Ce texte est celui d'une conference-rapport prononcee au Colloque International de Riso en 1959. On indique les techniques de mesures de la contamination radioactive de l'atmosphere et les principaux resultats obtenus jusqu'ici au CEA pour: Rn et Tn et leurs derives, H-3, C-14, A-41, Kr-85, I-131, et l'ensemble des produits de fission. (auteur)

  13. Effets thermoelectrique et thermomagnetique du yttrium barium copper oxide monocristallin

    Science.gov (United States)

    Ghamlouche, Hassan

    1998-09-01

    les plans de maclage. Nous avons observe, pour le premier angle un mouvement libre du vortex, pour le second angle une contribution de l'effet Nernst a l'effet Seebeck et pour la troisieme direction un phenomene d'activation. Dans ce dernier cas, les plans de maclage font un obstacle qui s'oppose au mouvement des vortex. De ce qui precede, nous concluons qu'avec la bonne resolution de notre technique nous sommes capables d'observer des phenomenes que la technique CC ne met pas en relief. D'autre part, la variete d'echantillons que nous avons etudies et les phenomenes que nous avons observes valorisent la presente etude.

  14. an assessment of methods for sampling carabid beetles

    African Journals Online (AJOL)

    Mgina

    collection of epigaeic (ground-dwelling) invertebrates (Southwood and Henderson,. 2000). It has been widely used for sampling carabid beetles in biodiversity inventories. (Niemela et al. 1994, Davies 2000, Nyundo. 2002), population and community ecology. (Greenslade 1968, Refseth, 1980,. Niemela1988, Niemela et al.

  15. Restauration et non-restauration en art contemporain 2,

    Directory of Open Access Journals (Sweden)

    Catherine Defeyt

    2010-04-01

    Full Text Available La diversification autant que la profusion des matériaux et techniques mis en œuvre dans le champ de la création artistique actuelle implique le collectage d’une documentation tout aussi riche et diversifiée de la part des responsables de collection.  Documenter l’art contemporain, c’est précisément sur ce thème que s’est clôturé le 5 juin 2008,le cycle des journées d’étude organisé par la section conservation-restauration des œuvres sculptées de l’École supérieure des beaux-arts de Tours (Es...

  16. Elemental analysis of water and soil environmental samples in Tabuk area by neutron capture gamma-ray spectroscopy techniques

    International Nuclear Information System (INIS)

    Al-Aseery, Sh.M.; Alamoudi, Z.; Hassan, A.M.

    2006-01-01

    The prompt and delayed gamma-rays due to neutron capture in the nuclei of the constituent elements of three soil samples and one drinking water sample have been measured. The 252 Cf and 226 Ra/Be isotopic neutron sources are used for neutron irradiation. Also, the hyper pure germanium detection system is used. The soil samples were from Astra, Tadco and El-Gammaz farms, while the water sample was taken from Tabuk city. In case of prompt gamma-ray analysis, a total of 16 elements were identified and the concentration percentage values by weight were calculated for: C, Na, Mg, Al, Si, S, Cl,, Ca, Ti, Cr, Mn, Fe, Co, Zn, Sr ad Pb elements. A comparative study between the results obtained in this work and the results obtained by ICP-MS and EDX-Ray techniques for the same samples is given

  17. Figures mythiques et histoire. Réinterprétations et contrastes entre Orient et Occident

    Directory of Open Access Journals (Sweden)

    Denise Aigle

    2009-05-01

    Full Text Available L'histoire de l'Orient musulman est jalonnée de grands personnages qui servent de modèles de référence et d'ancêtres fondateurs, certains hérités de l'islam, d'autres de l'Antiquité et de la Bible. Leur figure s'est transformée en Orient musulman à partir du Xe siècle, largement sous l'influence du Shâh-nâma, quand se sont multipliées les dynasties indépendantes, puis à la suite de l'irruption des Turcs, des Croisés et des Mongols. Les exemples de Saladin et de Gengis Khan illustrent le renouvellement des modèles, leur extension et leurs réinterprétations successives. La créativité mythique apparaît comme un acte culturel, de portée éminemment politique. La carrière d'un grand conquérant comme Tamerlan a servi de modèle à ses épigones pour justifier leurs prétentions territoriales. Les références bibliques attestées dans le Coran ont permis d'intégrer les Turcs, puis les Mongols, dans l'histoire de la Création, comme descendants de l'un des trois fils de Noé. Des rattachements bibliques anciens ont valorisé les musulmans des régions de la Volga à partir du XVIIIe siècle, ainsi que les différents peuples chrétiens et musulmans du Caucase, région riche en références bibliques comme l'échouage de l'arche de Noé sur le mont Ararat et l'enfermement des peuples de Gog et Magog derrière des portes de fer.

  18. Figures mythiques et histoire. Réinterprétations et contrastes entre Orient et Occident

    OpenAIRE

    Aigle, Denise

    2009-01-01

    L'histoire de l'Orient musulman est jalonnée de grands personnages qui servent de modèles de référence et d'ancêtres fondateurs, certains hérités de l'islam, d'autres de l'Antiquité et de la Bible. Leur figure s'est transformée en Orient musulman à partir du Xe siècle, largement sous l'influence du Shâh-nâma, quand se sont multipliées les dynasties indépendantes, puis à la suite de l'irruption des Turcs, des Croisés et des Mongols. Les exemples de Saladin et de Gengis Khan illustrent le renou...

  19. Microfabricated Devices for Sample Extraction, Concentrations, and Related Sample Processing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Gang; Lin, Yuehe

    2006-12-01

    This is an invited book chapter. As with other analytical techniques, sample pretreatments, sample extraction, sample introduction, and related techniques are of extreme importance for micro-electro-mechanical systems (MEMS). Bio-MEMS devices and systems start with a sampling step. The biological sample then usually undergoes some kinds of sample preparation steps before the actual analysis. These steps may involve extracting the target sample from its matrix, removing interferences from the sample, derivatizing the sample to detectable species, or performing a sample preconcentration step. The integration of the components for sample pretreatment into microfluidic devices represents one of the remaining the bottle-neck towards achieving true miniaturized total analysis systems (?TAS). This chapter provides a thorough state-of-art of the developments in this field to date.

  20. Teknik Sampling Snowball dalam Penelitian Lapangan

    Directory of Open Access Journals (Sweden)

    Nina Nurdiani

    2014-12-01

    Full Text Available Field research can be associated with both qualitative and quantitative research methods, depending on the problems faced and the goals to be achieved. The success of data collection in the field research depends on the determination of the appropriate sampling technique, to obtain accurate data, and reliably. In studies that have problems related to specific issues, requiring a non-probability sampling techniques one of which is the snowball sampling technique. This technique is useful for finding, identifying, selecting and taking samples in a network or chain of relationships. Phased implementation procedures performed through interviews and questionnaires. Snowball sampling technique has strengths and weaknesses in its application. Field research housing sector become the case study to explain this sampling technique.

  1. Sample preparation technique for transmission electron microscopy anodized Al-Li-SiC metal matrix composite

    International Nuclear Information System (INIS)

    Shahid, M.; Thomson, G.E.

    1997-01-01

    Along with improved mechanical properties, metal matrix composites (MMC) have a disadvantage of enhanced corrosion susceptibility in aggressive environments. Recent studies on corrosion behaviour of an Al-alloy 8090/SiC MMC, revealed considerably high corrosion rates of the MMC in near neutral solutions containing chloride ions. Anodizing is one of the potential surface treatment for the MMC to provide protective coating against corrosion. The surface and cross section of the anodized MMC can easily be observed using scanning electron microscope. The anodizing behaviour of the MMC can be understood further if the anodized cross section in examined under transmission electron microscope (TEM). However, it is relatively difficult to prepare small (3 mm diameter) electron transparent specimens of the MMC supporting an anodic film. In the present study a technique has been developed for preparing thin electron transparent specimens of the anodized MMC. This technique employed conventional ion beam thinning process but the preparation of small discs was a problem. A MMMC consisting of Al-alloy 8090 with 20 % (by weight) SiC particulate with an average size of 5 Mu m, was anodized and observed in TEM after preparing the samples using the above mentioned techniques. (author)

  2. Planetary Protection for LIFE-Sample Return from Enceladus

    Science.gov (United States)

    Tsou, Peter; Yano, Hajime; Takano, Yoshinori; McKay, David; Takai, Ken; Anbar, Ariel; Baross, J.

    Introduction: We are seeking a balanced approach to returning Enceladus plume samples to state-of-the-art terrestrial laboratories to search for signs of life. NASA, ESA, JAXA and other space agencies are seeking habitable worlds and life beyond Earth. Enceladus, an icy moon of Saturn, is the first known body in the Solar System besides Earth to emit liquid water from its interior. Enceladus is the most accessible body in our Solar System for a low cost flyby sample return mission to capture aqueous based samples, to determine its state of life development, and shed light on how life can originate on wet planets/moons. LIFE combines the unique capabilities of teams of international exploration expertise. These returned Enceladus plume samples will determine if this habitable body is in fact inhabited [McKay et al, 2014]. This paper describes an approach for the LIFE mission to capture and return samples from Enceladus while meeting NASA and COSPAR planetary protection requirements. Forward planetary protection requirements for spacecraft missions to icy solar system bodies have been defined, however planetary protection requirements specific to an Earth return of samples collected from Enceladus or other Outer Planet Icy Moons, have yet to be defined. Background: From the first half century of space exploration, we have returned samples only from the Moon, comet Wild 2, the Solar Wind and the asteroid Itokawa. The in-depth analyses of these samples in terrestrial laboratories have yielded detailed chemical information that could not have been obtained otherwise. While obtaining samples from Solar System bodies is trans-formative science, it is rarely performed due to cost and complexity. The discovery by Cassini of geysers on Enceladus and organic materials in the ejected plume indicates that there is an exceptional opportunity and strong scientific rationale for LIFE. The earliest low-cost possible flight opportunity is the next Discovery Mission [Tsou et al 2012

  3. Introduction of sample tubes with sodium azide as a preservative for ethyl glucuronide in urine.

    Science.gov (United States)

    Luginbühl, Marc; Weinmann, Wolfgang; Al-Ahmad, Ali

    2017-09-01

    Ethyl glucuronide (EtG) is a direct alcohol marker, which is widely used for clinical and forensic applications, mainly for abstinence control. However, the instability of EtG in urine against bacterial degradation or the post-collectional synthesis of EtG in contaminated samples may cause false interpretation of EtG results in urine samples. This study evaluates the potential of sodium azide in tubes used for urine collection to hinder degradation of ethyl glucuronide by bacterial metabolism taking place during growth of bacterial colonies. The tubes are part of a commercial oral fluid collection device. The sampling system was tested with different gram-positive and gram-negative bacterial species previously observed in urinary tract infections, such as Escherichia coli, Staphylococcus aureus, Enterecoccus faecalis, Staphylococcus epidermidis, Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomonas aeruginosa. Inhibition of bacterial growth by sodium azide, resulting in lower numbers of colony forming units compared to control samples, was observed for all tested bacterial species. To test the prevention of EtG degradation by the predominant pathogen in urinary tract infection, sterile-filtered urine and deficient medium were spiked with EtG, and inoculated with E. coli prior to incubation for 4 days at 37 °C in tubes with and without sodium azide. Samples were collected every 24 hours, during four consecutive days, whereby the colony forming units (CFU) were counted on Columbia blood agar plates, and EtG was analyzed by LC-MS/MS. As expected, EtG degradation was observed when standard polypropylene tubes were used for the storage of contaminated samples. However, urine specimens collected in sodium azide tubes showed no or very limited bacterial growth and no EtG degradation. As a conclusion, sodium azide is useful to reduce bacterial growth of gram-negative and gram-positive bacteria. It inhibits the degradation of EtG by E. coli and can be used for

  4. Non-destructive high-resolution thermal imaging techniques to evaluate wildlife and delicate biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Lavers, C; Franklin, P; Franklin, P; Plowman, A; Sayers, G; Bol, J; Shepard, D; Fields, D, E-mail: brnc-radarcomms1@nrta.mod.u [Sensors Team, Plymouth University at Britannia Royal Naval College, Dartmouth, Devon (United Kingdom) and Paignton Zoological Park, Paignton, Devon (United Kingdom); Thermal Wave Imaging, Inc., 845 Livernoise St, Ferndale, MI (United States); Buckfast Butterfly and Otter Sanctuary, Buckfast, Devon (United Kingdom)

    2009-07-01

    Thermal imaging cameras now allows routine monitoring of dangerous yet endangered wildlife in captivity. This study looks at the potential applications of radiometrically calibrated thermal data to wildlife, as well as providing parameters for future materials applications. We present a non-destructive active testing technique suitable for enhancing imagery contrast of thin or delicate biological specimens yielding improved thermal contrast at room temperature, for analysis of sample thermal properties. A broad spectrum of animals is studied with different textured surfaces, reflective and emissive properties in the infra red part of the electromagnetic spectrum. Some surface features offer biomimetic materials design opportunities.

  5. Non-destructive high-resolution thermal imaging techniques to evaluate wildlife and delicate biological samples

    International Nuclear Information System (INIS)

    Lavers, C; Franklin, P; Franklin, P; Plowman, A; Sayers, G; Bol, J; Shepard, D; Fields, D

    2009-01-01

    Thermal imaging cameras now allows routine monitoring of dangerous yet endangered wildlife in captivity. This study looks at the potential applications of radiometrically calibrated thermal data to wildlife, as well as providing parameters for future materials applications. We present a non-destructive active testing technique suitable for enhancing imagery contrast of thin or delicate biological specimens yielding improved thermal contrast at room temperature, for analysis of sample thermal properties. A broad spectrum of animals is studied with different textured surfaces, reflective and emissive properties in the infra red part of the electromagnetic spectrum. Some surface features offer biomimetic materials design opportunities.

  6. Endodontic pathogens causing deep neck space infections: clinical impact of different sampling techniques and antibiotic susceptibility.

    Science.gov (United States)

    Poeschl, Paul W; Crepaz, Valentina; Russmueller, Guenter; Seemann, Rudolf; Hirschl, Alexander M; Ewers, Rolf

    2011-09-01

    The aims of the present study were to compare microbial populations in patients suffering from deep neck space abscesses caused by primary endodontic infections by sampling the infections with aspiration or swabbing techniques and to determine the susceptibility rates of the isolated bacteria to commonly used antibiotics. A total of 89 patients with deep neck space abscesses caused by primary endodontic infections requiring extraoral incision and drainage under general anesthesia were included. Either aspiration or swabbing was used to sample microbial pus specimens. The culture of the microbial specimens and susceptibility testing were performed following standard procedures. A total of 142 strains were recovered from 76 patients. In 13 patients, no bacteria were found. The predominant bacteria observed were streptococci (36%), staphylococci (13%), Prevotella (8%), and Peptostreptococcus (6%). A statistically significant greater number of obligate anaerobes were found in the aspiration group. The majority of patients presented a mixed aerobic-anaerobic population of bacterial flora (62%). The antibiotic resistance rates for the predominant bacteria were 10% for penicillin G, 9% for amoxicillin, 0% for amoxicillin clavulanate, 24% for clindamycin, and 24% for erythromycin. The results of our study indicated that a greater number of anaerobes were found when sampling using the aspiration technique. Penicillin G and aminopenicillins alone are not always sufficient for the treatment of severe deep neck space abscesses; beta-lactamase inhibitor combinations are more effective. Bacteria showed significant resistant rates to clindamycin. Thus, its single use in penicillin-allergic patients has to be carefully considered. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. A review of micro-wave techniques in plasma studies; Survol des techniques micro-ondes pour l'etude des plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Consoli, T [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The problem of the application of micro-wave techniques to the study of plasma properties is considered in this report. In section I, the author summarizes a few fundamental laws concerning the theory of waves in an ionised medium as well as measurable effects of transverse and longitudinal propagation. Section II is a rapid review of the experimental methods and of the various measurements which may be effected in very high frequency plasmas. Only recent experimental work carried out since the last U. R.S.I. Assembly is considered. Section III is devoted to micro-wave techniques developed during this period in the laboratories of the Applied Physics Service. These techniques deal with longitudinal propagation and in particular with the propagation along a right mode. Section IV is a general view of similar studies undertaken in European Research Centres working on plasma physics or controlled fusion. Section V is a contribution concerning three particular topics from the Juelich and Max Planck Institute laboratories. (author) [French] On etudie dans ce rapport le probleme de l'application des techniques micro-ondes a l'etude des proprietes d'un plasma. Dans la section I, l'auteur rappelle rapidement quelques lois fondamentales de la theorie des ondes dans un milieu ionise ainsi que les effets mesurables en propagation transversale et longitudinale. La section II est une revue rapide des methodes experimentales et des diverses mesures qui peuvent etre faites dans les plasmas aux tres hautes frequences. On ne considere seulement que les etudes experimentales recentes depuis la derniere assemblee de l'U.R.S.I. La section III est consacree aux techniques hyperfrequences developpees durant la meme periode dans les laboratoires des Services de Physique Appliquee. Ces techniques se rapportent a la propagation longitudinale et particulierement a la propagation suivant le mode droit. La section IV est un panorama de travaux similaires entrepris dans les centres europeens

  8. More Poop, More Precision: Improving Epidemiologic Surveillance of Soil-Transmitted Helminths with Multiple Fecal Sampling using the Kato-Katz Technique.

    Science.gov (United States)

    Liu, Chengfang; Lu, Louise; Zhang, Linxiu; Bai, Yu; Medina, Alexis; Rozelle, Scott; Smith, Darvin Scott; Zhou, Changhai; Zang, Wei

    2017-09-01

    Soil-transmitted helminths, or parasitic intestinal worms, are among the most prevalent and geographically widespread parasitic infections in the world. Accurate diagnosis and quantification of helminth infection are critical for informing and assessing deworming interventions. The Kato-Katz thick smear technique, the most widely used laboratory method to quantitatively assess infection prevalence and infection intensity of helminths, has often been compared with other methods. Only a few small-scale studies, however, have considered ways to improve its diagnostic sensitivity. This study, conducted among 4,985 school-age children in an area of rural China with moderate prevalence of helminth infection, examines the effect on diagnostic sensitivity of the Kato-Katz technique when two fecal samples collected over consecutive days are examined and compared with a single sample. A secondary aim was to consider cost-effectiveness by calculating an estimate of the marginal costs of obtaining an additional fecal sample. Our findings show that analysis of an additional fecal sample led to increases of 23%, 26%, and 100% for Ascaris lumbricoides, Trichuris trichiura , and hookworm prevalence, respectively. The cost of collecting a second fecal sample for our study population was approximately USD4.60 per fecal sample. Overall, the findings suggest that investing 31% more capital in fecal sample collection prevents an underestimation of prevalence by about 21%, and hence improves the diagnostic sensitivity of the Kato-Katz method. Especially in areas with light-intensity infections of soil-transmitted helminths and limited public health resources, more accurate epidemiological surveillance using multiple fecal samples will critically inform decisions regarding infection control and prevention.

  9. Français, autoformation et ELAO à l’université : didactique du texte et pratique de l’hypertexte Français, autoformation et ELAO à l’université : didactique du texte et pratique de l’hypertexte

    Directory of Open Access Journals (Sweden)

    Michèle Redon-Dilax

    2000-06-01

    Full Text Available L´autoformation en français à Paris VI vise essentiellement les étudiants scientifiques et techniques des nouvelles formations professionnelles. L´objectif linguistique de cette formation étant le traitement de l´écrit, nous concevons des outils d´aide à la lecture et la rédaction. Au plan scientifique nous puisons à divers modèles (théories de l´énonciation, sémantique et pragmatique du discours, linguistique textuelle. Au plan didactique nous cherchons à développer la maîtrise des procédures de reprise et de progression des informations dans et vers un tout cohérent. Du point de vue de l´ingénierie de formation nous nous situons dans la perspective d´un dispositif multimédia qui permet l´individualisation et favorise l´autonomie. Dans ce cadre, nos choix théoriques et méthodologiques nous ont amenés jusqu´à présent à réaliser des logiciels relevant plutôt des " EAO classiques ". À l´heure de l´Internet et de la généralisation de l´approche hypermédia nous sommes amenés à nous interroger sur la manière de faire évoluer nos productions de type " classique " en y introduisant un mode de lecture hypertextuel. Nous nous appuyons sur un exemple tiré de nos productions antérieures pour mettre en évidence, au plan de l´écriture, un certain nombre de difficultés n��es du souci de concilier linéarité du discours didactique et liberté de circulation.Selftraining in French at Paris VI applies essentially to the students of the new vocational technical and scientific trainings. As the linguistic objective of this training is to have command of the written language, we propose tools for readings and essays. At the scientific level we draw from various models (semantics and pragmatics, enunciation, textual linguistics. At the didactic level we attempt to develop skills concerning the repeat and the progression of information in and to a coherent whole. From the point of view of the engineering of

  10. Sampling technique for collection of expired COsub(2) in studies using naturally labelled sup(13)C in calves

    International Nuclear Information System (INIS)

    Chevalier, R.; Pelletier, G.; Gagnon, M.

    1984-01-01

    Natural isotopic labelling of animal metabolic processes presents great advantages over the use of artificially enriched compounds. These advantages include the use of natural diets, low cost and easiness of handling, sampling and disposal. Changes in the sup(13)C/sup(12)C ratio of expired COsub(2) after ingestion of a test meal containing a variable proportion of Csub(3) and/or Csub(4) plant-derived products permits measurements of the immediate oxidation of dietary carbohydrates. A breathing device for collection of expired COsub(2) and purification techniques are described. The breath-sampling device is composed of a polypropylene enclosure and a rubber bag. The rubber bag is blown up by the animal and a sample of the expired gas is transferred to a sampling glass holder in which a vacuum had been previously achieved. Sample purification of expired COsub(2) is done by differential freezing

  11. Et kors er ikke bare et kors

    DEFF Research Database (Denmark)

    Bach-Nielsen, Carsten

    2015-01-01

    Om et kors, der er rejst uden for den danske kirke i Bruxelles; formodentlig en afledning af det såkaldte Brabanterkors.......Om et kors, der er rejst uden for den danske kirke i Bruxelles; formodentlig en afledning af det såkaldte Brabanterkors....

  12. Tank 241-SY-101 push mode core sampling and analysis plan

    International Nuclear Information System (INIS)

    CONNER, J.M.

    1998-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for push mode core samples from tank 241-SY-101 (SY-101). It is written in accordance with Data Quality Objective to Support Resolution of the Flammable Gas Safety Issue (Bauer 1998), Low Activity Waste Feed Data Quality Objectives (Wiemers and Miller 1997 and DOE 1998), Data Quality Objectives for TWRS Privatization Phase I: Confirm Tank T is an Appropriate Feed Source for Low-Activity Waste Feed Batch X (Certa 1998), and the Tank Safety Screening Data Quality Objective (Dukelow et al. 1995). The Tank Characterization Technical Sampling Basis document (Brown et al. 1998) indicates that these issues apply to tank SY-101 for this sampling event. Brown et al. also identifies high-level waste, regulatory, pretreatment and disposal issues as applicable issues for this tank. However, these issues will not be addressed via this sampling event

  13. Contrôle non destructif par courants de Foucault : expérience et modélisation pour la conception et l'optimisation de capteurs

    Science.gov (United States)

    Bonnin, O.; Cahouet, J.; Giordano, P.

    1993-03-01

    For inspecting tubular steel subsea structures, the conventional non destructive testing techniques require the removal of the marine fouling and corrosion protection coatings. These costly cleaning operations down to bare metal can be avoided with a new contactless technique which has been developed by the “Institut Français de Recherche et d'Exploitation de la Mer”. This technique consists in inducing a strong alternative electric current flow at several frequencies in the material. Corresponding localized perturbations of this current flow caused by defects such as inclusions or cracks are then detected. The current perturbation is sensed with a small non contacting probe to detect the associated magnetic flux signal at the surface of the structure. Exploratory experiments allow us to conclude that this technique is very promising. The improvements in sensitivity and in characterization of the defects need a better quantitative understanding of the way in which slots in conducting materials interact with electric currents. We propose a numerical model, using our software : the Trifou code. This code solves tridimensionnal electromagnetic problems, by computing the current density in massive conductors under the effect of a known and time varying electromagnetic excitation. By taking advantage of our experience in modelling the eddy current testing of the french nuclear power plants, we have reproduced one of the experiments. Numerical results are presented and make the deflection of current lines at slot edges visible. The electric activity of the modeled slot has been pointed out and we suggest that the flaw may be interpreted as a back electromotive force source which creates divergence free local currents. Then, we have established a numerical method based on a local approach, to obtain the defect signal with a low computing cost. Numerical results fit the shape of the experimental results. In particular, we can determine the position of the crack. A

  14. Treatment and final conditioning of solid radioactive wastes; Traitement et conditionnement definitif des dechets radioactifs solides

    Energy Technology Data Exchange (ETDEWEB)

    Cerre, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The storage of solid radioactive wastes on a site is so cumbersome and dangerous that we have developed a method of treatment and conditioning by means of which the volume of waste is considerably reduced and very long-lasting shielding can be provided. This paper describes the techniques adopted at Saclay, where the wastes are sheared, compressed and enveloped in concrete of variable thickness. The main part of the report is devoted to a description of the corresponding remote handling installation. (author) [French] L'encombrement et le danger que presentent sur un site le stockage de dechets radioactifs solides nous ont amenes a etudier un mode de traitement et de conditionnement permettant une sensible reduction du volume des dechets et une protection de tres longue duree. La presente communication expose les techniques adoptees a Saclay ou les dechets sont cisailles, comprimes et enrobes dans du beton d'epaisseur variable. La description de l'installation telecommandee correspondante fait l'objet principal de cette communication. (auteur)

  15. Par les fruits et légumes, l’interprétation de différents patrimoines

    OpenAIRE

    Grison, Pauline

    2011-01-01

    À partir de l’analyse d’un programme muséographique organisé autour d’un patrimoine naturel, culturel, technique et industriel lié aux fruits et légumes et qui a choisi l’activité d’interprétation comme forme de médiation, l’auteur montre comment cette démarche spécifique permet de concilier l’exigence de fiabilité attachée à l’institution muséale et le respect des intérêts économiques des acteurs de la filière porteurs du projet.

  16. Education civique et morale au Togo - diagnostic : stratégies et ...

    African Journals Online (AJOL)

    Education civique et morale (ECM), cette étude entreprend un diagnostic des pratiques ... l'étude propose des paramètres de refondation et d'innovations curriculaires, et en développe des exigences fondamentales, les stratégies opératoires et les ...

  17. On-line hydrogen-isotope measurements of organic samples using elemental chromium: An extension for high temperature elemental-analyzer techniques

    Science.gov (United States)

    Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B.; Meijer, Harro A.J.; Brand, Willi A.; Schimmelmann, Arndt

    2015-01-01

    The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ2H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ2H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while

  18. On-line hydrogen-isotope measurements of organic samples using elemental chromium: an extension for high temperature elemental-analyzer techniques.

    Science.gov (United States)

    Gehre, Matthias; Renpenning, Julian; Gilevska, Tetyana; Qi, Haiping; Coplen, Tyler B; Meijer, Harro A J; Brand, Willi A; Schimmelmann, Arndt

    2015-01-01

    The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ(2)H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ(2)H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while

  19. Science et Technique, Sciences de la Santé - Vol 34, No 1-2 (2011)

    African Journals Online (AJOL)

    Consommation des psychotropes en milieu scolaire, au Burkina Faso : Prévalences et facteurs de risque · EMAIL FULL TEXT EMAIL FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. L Nikiéma, S Kouanda, I Seck, S Tiendrebéogo, HG Ouédraogo, M Yaméogo, B Méda, B Doulogou, I Guissou, B Sondo, 65- ...

  20. Science et Technique, Sciences de la Santé - Vol 39, No 1-2 (2016)

    African Journals Online (AJOL)

    Cardiomyopathie du péri-partum prise en charge en milieu Hospitalier Universitaire de Bobo-Dioulasso : aspects thérapeutiques et évolutifs · EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. S. J-B. Tougouma, A.A. Yaméogo, A. Dembélé, G. Kinda, N.V. Yaméogo, G.R.C. Millogo, ...

  1. Fiches techniques Les triacylglycérols des huiles de graines de quatre Cucurbitacées tropicales des genres Lagenaria et Luffa

    Directory of Open Access Journals (Sweden)

    Grondin Isabelle

    2002-03-01

    Full Text Available Les huiles de graines de quatre Cucurbitacées tropicales de l’île de la Réunion, provenant respectivement de deux variétés de l’espèce Lagenaria leucaritha (calebasses bouteille et la gale et de deux espèces du genre Luffa (pipangailles lisse et à côtes, ont été analysées aussi bien pour la fraction saponifiable que pour la fraction insaponifiable. L’étude de la fraction saponifiable a été consacrée, d’une part, à la détermination de la composition quantitative et qualitative en acides gras des différentes huiles dont les résultats ont fait l’objet d’une publication antérieure [1] et, d’autre part, à celle de leurs triacylglycérols. Une comparaison des compositions en acides gras des deux genres étudiés a permis de mettre en évidence les spécificités propres à chaque genre. Les genres Lagenaria et Luffa, présentant une composition en acides gras qualitativement similaire, contiennent ainsi les AG couramment rencontrés dans le règne végétal, à savoir les acides palmitique, stéarique, oléique et linoléique. Ce dernier est, par ailleurs, l’acide gras majoritaire avec des teneurs supérieures à 50%. La présence de cet acide gras essentiel confère ainsi à ces huiles de bonnes propriétés diététiques et nutritionnelles. Au sein du genre Lagenaria, les huiles des graines des variétés bouteille et la gale se caractérisent par leur teneur élevée en acide linoléique (71,5% pour la variété bouteille, et 81,5% pour la variété la gale. Les huiles de Lagenaria leucaritha sont du type palmitique-linoléique car ces deux acides gras représentent quantitativement plus de 85% des AG totaux. Contrairement à ces deux huiles, celles du genre Luffa se différencient, d’une part, par une teneur moindre en acide linoléique avec 55,3% pour l’espèce Luffa acutangula et 51,2% pour l’espèce Luffa cylindrica. D’autre part, elles sont du type palmitique-oléique-linoléique puisque ces trois

  2. I Replicanti: culti abusanti e tecniche di manipolazione mentale / Les Répliquants : cultes destructifs et techniques de manipulation mentale / “Replicants”: destructive cults and mechanisms of mental manipulation

    Directory of Open Access Journals (Sweden)

    Santovecchi P.

    2010-12-01

    Full Text Available Potenzialmente, tutti possiamo essere condizionati o condizionabili. È indubbio che ognuno di noi sia soggetto all’influenza di molti fattori: il luogo in cui nasciamo, la nostra famiglia di origine, le amicizie, la scuola, le esperienze di vita, senza sottovalutare i media e le varie mode e tendenze. Tutto contribuisce a plasmare la nostra identità e fare di noi ciò che siamo quanto a modo di pensare e di agire. Esiste però una tecnica ben più forte e subdola di condizionamento messa in atto, nel corso degli ultimi decenni, da culti che studiosi e osservatori non hanno esitato a definire “distruttivi”. Sono culti che aspirano al controllo completo della persona e delle sue risorse dai quali potremo proteggerci solo conoscendone a fondo i procedimenti. Mettere in chiaro i meccanismi del condizionamento mentale significa, quindi, cercare le radici ultime di ogni convivenza “civile”, risalire alle fonti stesse di ogni contratto sociale. Significa anche sondare i confini tra razionalità ed emozioni, tra meccanicismi cognitivi da tutti condivisi e particolari opinioni di un gruppo. Da qui la necessità di un’informazione specifica su come sia possibile influenzare le persone attraverso “processi condizionanti”. Potentiellement, nous pouvons tous être conditionnés ou objet de conditionnement. Il est indubitable que chacun de nous est soumis à l'influence de plusieurs facteurs : le lieu de naissance, la famille d'origine, les amitiés, l'école, les expériences de vie, sans sous-estimer l’influence des médias et des différentes modes et tendances. Tout contribue à modeler notre identité et à faire de nous ce que nous sommes, en termes de manières de penser et d'agir. Il existe cependant une technique bien plus forte et sournoise de conditionnement, mise en place, au cours des dernières décennies, par certains cultes que les spécialistes n’ont pas hésité à définir comme « destructifs » . Il s’agit de

  3. Le Silurien du Synclinorium de Moncorvo (NE du Portugal): Biostratigraphie et Importance Paléogéographique

    Czech Academy of Sciences Publication Activity Database

    Sarmiento, G. N.; Picarra, J. M.; Rebelo, J. A.; Robardet, M.; Gutiérrez-Marco, J. C.; Štorch, Petr; Rábano, I.

    1999-01-01

    Roč. 32, č. 5 (1999), s. 749-767 ISSN 0016-6995 R&D Projects: GA AV ČR Projects 351 et 421 du Programme International de Corrélation Géologique et au Projet Iberian Variscides du programme Europrobe, Projet 061-B0 du Programme de Coopération Scientifique et Technique Franco-Portugais Subject RIV: DB - Geology ; Mineralogy Impact factor: 0.736, year: 1999

  4. influence des engins et techniques de peche sur l'abondance

    African Journals Online (AJOL)

    ACSS

    17 févr. 2017 ... calculated using XLSTAT Software. Ordinary kriging technique in ArcGis 9.3 Software was used to map the measured ... Further studies are needed to develop a plan for sustainable management of the fisheries ...... sustainability in the Lake Victoria basin: an ... Management of large Rivers for Fisheries,.

  5. Martian regolith geochemistry and sampling techniques

    Science.gov (United States)

    Clark, B. C.

    Laboratory study of samples of the intermediate and fine-grained regolith, including duricrust peds, is a fundamental prerequisite for understanding the types of physical and chemical weathering processes on Mars. The extraordinary importance of such samples is their relevance to understanding past changes in climate, availability (and possible physical state) of water, eolian forces, the thermal and chemical influences of volcanic and impact processes, and the inventory and fates of Martian volatiles. Fortunately, this regolith material appears to be ubiquitous over the Martian surface, and should be available at many different landing sites. Viking data has been interpreted to indicate a smectite-rich regolith material, implying extensive weathering involving aqueous activity and geochemical alteration. An all-igneous source of the Martian fines has also been proposed. The X-ray fluorescence measurement data set can now be fully explained in terms of a simple two-component model. The first component is silicate, having strong geochemical similarities with Shergottites, but not other SNC meteorites. The second component is salt. Variations in these components could produce silicate and salt-rich beds, the latter being of high potential importance for microenvironments in which liquid water (brines) could exist. It therefore would be desirable to scan the surface of the regolith for such prospects.

  6. Martian regolith geochemistry and sampling techniques

    Science.gov (United States)

    Clark, B. C.

    1988-01-01

    Laboratory study of samples of the intermediate and fine-grained regolith, including duricrust peds, is a fundamental prerequisite for understanding the types of physical and chemical weathering processes on Mars. The extraordinary importance of such samples is their relevance to understanding past changes in climate, availability (and possible physical state) of water, eolian forces, the thermal and chemical influences of volcanic and impact processes, and the inventory and fates of Martian volatiles. Fortunately, this regolith material appears to be ubiquitous over the Martian surface, and should be available at many different landing sites. Viking data has been interpreted to indicate a smectite-rich regolith material, implying extensive weathering involving aqueous activity and geochemical alteration. An all-igneous source of the Martian fines has also been proposed. The X-ray fluorescence measurement data set can now be fully explained in terms of a simple two-component model. The first component is silicate, having strong geochemical similarities with Shergottites, but not other SNC meteorites. The second component is salt. Variations in these components could produce silicate and salt-rich beds, the latter being of high potential importance for microenvironments in which liquid water (brines) could exist. It therefore would be desirable to scan the surface of the regolith for such prospects.

  7. Le moulage pour la reconstitution des lacunes en restauration de la céramique et du verre

    Directory of Open Access Journals (Sweden)

    Hélène Blanpain

    2012-06-01

    Full Text Available La technique de reconstitution des lacunes par moulage est très vaste. Elle présente une large gamme de produits et de procédés susceptibles d’être employés dans le domaine de la restauration de la céramique et du verre. Leur choix et leur bonne mise en œuvre dépendront de plusieurs facteurs comme la nature de l’élément à mouler, sa forme et la nature du matériau de comblement choisi.The technique of gap-filling by molding is very vast. It presents a wide range of products and processes than can be used in the field of the restoration of ceramic and glass objects. Their choice depends on several factors : the material of the object, its shape, and the choice of the filling product.

  8. Bases de données NoSQL et Big Data concevoir des bases de données pour le Big Data : cours et travaux pratiques niveau B

    CERN Document Server

    Lacomme, Philippe; Phan, Raksmey

    2014-01-01

    Les bases de données NoSQL, ou non relationnelles, procèdent d'une logique différente du modèle SQL pour stocker de très grands volumes de données de natures variées. Elles s'affranchissent des contraintes classiques et fournissent une architecture nouvelle, souple et performante. Le Big Data rassemble des technologies répondant aux 4 V : Volume important, Variété d'informations, Vélocité du traitement, Variabilité des sources. L'ouvrage s'emploie à rendre ces techniques accessibles. Il propose une présentation synthétique des systèmes de bases de données NoSQL dans une approche transversale sur plusieurs plateformes : NetBeans et Eclipse. Le propos est constamment illustré par de nombreux exemples implémentés sous forme de travaux pratiques utilisant : Oracle, MongoDB, Cassandra, Neo4j, Redi et Hbase. Des vidéos et des compléments gratuits sont disponibles sur le site web du livre : http://www.isima.fr/~lacomme/NoSQL/."

  9. Whole arm manipulation planning based on feedback velocity fields and sampling-based techniques.

    Science.gov (United States)

    Talaei, B; Abdollahi, F; Talebi, H A; Omidi Karkani, E

    2013-09-01

    Changing the configuration of a cooperative whole arm manipulator is not easy while enclosing an object. This difficulty is mainly because of risk of jamming caused by kinematic constraints. To reduce this risk, this paper proposes a feedback manipulation planning algorithm that takes grasp kinematics into account. The idea is based on a vector field that imposes perturbation in object motion inducing directions when the movement is considerably along manipulator redundant directions. Obstacle avoidance problem is then considered by combining the algorithm with sampling-based techniques. As experimental results confirm, the proposed algorithm is effective in avoiding jamming as well as obstacles for a 6-DOF dual arm whole arm manipulator. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Uses of neutron capture gamma-rays in environmental pollution applications

    International Nuclear Information System (INIS)

    AbdAl-Samad, M.A.

    1998-01-01

    As a sensitive and accurate technique, the prompt gamma-rays neutron activation is used with success for elemental analysis. The advantages of this method over the other techniques are rapidity, usage of relatively large sample size and high reliability, beside the detection of the elements which have no gamma activity during the delayed neutron activation analysis or very short lived isotopes. Actually different techniques could be used for estimating the trace, minor and major elements of these environmental samples which are considered as complex samples. In the mean time the neutron activation analysis techniques have been improved and have become an excellent tool for elemental analysis of complex samples (Duffey et al., 1970; Senftle et al., 1971; Henkelmm and Born, 1973 ; Hassan et al., .; 1981, 1982, 1983; Clyton et al., 1983; Zaghloul et al., 1993) and the advantages of the prompt γ- ray neutron activation analysis over the other techniques put this technique in the fore front

  11. Evaluation of dry blood spot technique for quantification of an Anti-CD20 monoclonal antibody drug in human blood samples.

    Science.gov (United States)

    Lin, Yong-Qing; Zhang, Yilu; Li, Connie; Li, Louis; Zhang, Kelley; Li, Shawn

    2012-01-01

    To evaluate the dried blood spot (DBS) technique in ELISA quantification of larger biomolecular drugs, an anti-CD20 monoclonal antibody drug was used as an example. A method for the quantification of the anti-CD20 drug in human DBS was developed and validated. The drug standard and quality control samples prepared in fresh human blood were spotted on DBS cards and then extracted. A luminescent ELISA was used for quantification of the drug from DBS samples. The assay range of the anti-CD20 drug standards in DBS was 100-2500ng/mL. The intra-assay precision (%CV) ranged from 0.4% to 10.1%, and the accuracy (%Recovery) ranged from 77.9% to 113.9%. The inter assay precision (%CV) ranged from 5.9% to 17.4%, and the accuracy ranged from 81.5% to 110.5%. The DBS samples diluted 500 and 50-fold yielded recovery of 88.7% and 90.7%, respectively. The preparation of DBS in higher and lower hematocrit (53% and 35%) conditions did not affect the recovery of the drug. Furthermore, the storage stability of the anti-CD20 drug on DBS cards was tested at various conditions. It was found that the anti-CD20 drug was stable for one week in DBS stored at room temperature. However, it was determined that the stability was compro]mised in DBS stored at high humidity, high temperature (55°C), and exposed to direct daylight for a week, as well as for samples stored at room temperature and high humidity conditions for a month. Stability did not change significantly in samples that underwent 3 freeze/thaw cycles. Our results demonstrated a successful use of DBS technique in ELISA quantification of an anti-CD20 monoclonal antibody drug in human blood. The stability data provides information regarding sample storage and shipping for future clinical studies. It is, therefore, concluded that the DBS technique is applicable in the quantification of other large biomolecule drugs or biomarkers. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Study of uranium mineralization in rock samples from marwat range bannu basin by fission track analysis technique

    International Nuclear Information System (INIS)

    Qureshi, A.Z.; Ullah, K.; Ullah, N.; Akram, M.

    2004-07-01

    The Geophysics Division, Atomic Energy Minerals Centre (AEMC), Lahore has planned a uranium exploration program in Marwat Range, Bannu Basin. In this connection 30 thin sections of rock samples, collected from four areas; namely, Darra Tang, Simukili, Karkanwal and Sheikhillah from Marwat Range, and one from Salt Range were provided to Nuclear Geology Group of Physics Research Division, PINSTECH for the study of nature and mechanism of uranium mineralization These studies are aimed to help in designing uranium exploration strategy by providing the loci of uranium sources in the Marwat and Salt Ranges. The samples have been studied using fission track analysis technique. (author)

  13. Direct Trace Element Analysis of Liquid Blood Samples by In-Air Ion Beam Analytical Techniques (PIXE-PIGE).

    Science.gov (United States)

    Huszank, Robert; Csedreki, László; Török, Zsófia

    2017-02-07

    There are various liquid materials whose elemental composition is of interest in various fields of science and technology. In many cases, sample preparation or the extraction can be complicated, or it would destroy the original environment before the analysis (for example, in the case of biological samples). However, multielement direct analysis of liquid samples can be realized by an external PIXE-PIGE measurement system. Particle-induced X-ray and gamma-ray emission spectroscopy (PIXE, PIGE) techniques were applied in external (in-air) microbeam configuration for the trace and main element determination of liquid samples. The direct analysis of standard solutions of several metal salts and human blood samples (whole blood, blood serum, blood plasma, and formed elements) was realized. From the blood samples, Na, P, S, Cl, K, Ca, Fe, Cu, Zn, and Br elemental concentrations were determined. The focused and scanned ion beam creates an opportunity to analyze very small volume samples (∼10 μL). As the sample matrix consists of light elements, the analysis is possible at ppm level. Using this external beam setup, it was found that it is possible to determine elemental composition of small-volume liquid samples routinely, while the liquid samples do not require any preparation processes, and thus, they can be analyzed directly. In the case of lower concentrations, the method is also suitable for the analysis (down to even ∼1 ppm level) but with less accuracy and longer measurement times.

  14. Mesurer et comparer les contextes et les politiques alimentaires en ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    En Amérique latine, les maladies non transmissibles (MNT) sont responsables de trois décès sur quatre. Une mauvaise alimentation fait augmenter de plus en plus les décès et les maladies évitables et prématurées liés aux MNT. Dans le but de régler ce problème, ce projet suivra et comparera les contextes et les ...

  15. Macro elemental analysis of food samples by nuclear analytical technique

    Science.gov (United States)

    Syahfitri, W. Y. N.; Kurniawati, S.; Adventini, N.; Damastuti, E.; Lestiani, D. D.

    2017-06-01

    Energy-dispersive X-ray fluorescence (EDXRF) spectrometry is a non-destructive, rapid, multi elemental, accurate, and environment friendly analysis compared with other detection methods. Thus, EDXRF spectrometry is applicable for food inspection. The macro elements calcium and potassium constitute important nutrients required by the human body for optimal physiological functions. Therefore, the determination of Ca and K content in various foods needs to be done. The aim of this work is to demonstrate the applicability of EDXRF for food analysis. The analytical performance of non-destructive EDXRF was compared with other analytical techniques; neutron activation analysis and atomic absorption spectrometry. Comparison of methods performed as cross checking results of the analysis and to overcome the limitations of the three methods. Analysis results showed that Ca found in food using EDXRF and AAS were not significantly different with p-value 0.9687, whereas p-value of K between EDXRF and NAA is 0.6575. The correlation between those results was also examined. The Pearson correlations for Ca and K were 0.9871 and 0.9558, respectively. Method validation using SRM NIST 1548a Typical Diet was also applied. The results showed good agreement between methods; therefore EDXRF method can be used as an alternative method for the determination of Ca and K in food samples.

  16. An intercomparison of sampling techniques among five European laboratories for measurements of radiocaesium in upland pasture and soil

    International Nuclear Information System (INIS)

    Nielsen, S.P.; Aarkrog, A.; Colgan, P.A.; McGee, E.; Synnott, H.J.; Johansson, K.J.; Horrill, A.D.; Kennedy, V.H.; Barbayiannis, N.

    1992-02-01

    An intercomparison of sampling procedures used by five European laboratories for the determination of radiocaesium in vegetation and peaty soil was carried out at two locations in Cumbria. The soil sampling procedures included th ecollection of depth profiles in order to obtain information on the vertical distribution of radiocaesium in addition to the total deposition. The number of samples taken by each laboratory varied from one to five. The multiple sampling has given information on the homogeneity of the parameters studied at each location. The parameters comprise soil bulk densities, total deposition of 137 Cs, deposition of 137 Cs in three soil layers, biomass densities, concentrations of 137 Cs in pasture, and activity ratios ( 134 Cs/ 137 Cs) in soil and vegetation. The determination of total deposition of 137 Cs gave no indication of differences between the laboratories. The total depositions of 134 Cs and 137 Cs observed at one site were compared with levels obtained from another study and the two sets of data were found to be in good agreement. The results from the soil profiles do indicate significant differences between laboratories. This covers the vertical distributions of 137 Cs deposition including the 134 Cs/ 137 Cs-activity ratios as well as the soil bulk densities. One laboratory using a coring technique observed difficulties during sampling due to compression of the soil. The coring technique should thus be avoided or applied with extreme care for the sampling of depth profiles in peaty soil. The results from the sampling of pasture show no indication of differences between the laboratories. For the parameters studied the observed variabilities across soil depths and locations range from 10% to 82% in terms of relative standard deviations. A comparison across all results at the two locations indicate a 50% higher field variability at one of the sites relative to the other. (au) (24 tabs., 9 ills., 3 refs.)

  17. Evaluation de Ia pratique transfusionnelle en urgence obstetricale et ...

    African Journals Online (AJOL)

    La collecte des donnees a ere faite par une technique d' observation directe et de revue documentaire. Sur cette periode, la frequence de la transfusion dans le service etait de 11,08 % par rapport a 1' ensemble des malades hospitalisees. Le delai moyen d' obtention des produits sanguins labiles etait de 2 h 46 minutes.

  18. Profil clinique et anatomopathologique des cancers de l'ovaire

    African Journals Online (AJOL)

    recueillies selon la méthode documentaire. Les données cliniques contenues dans chaque dossier ont été consignées sur une fiche technique anonyme. Celles relatives au diagnostic anatomopathologique ont été relevées à partir des archives des diagnostics du service d'anatomie et de cytologie pathologiques.

  19. Secondary signal imaging (SSI) electron tomography (SSI-ET): A new three-dimensional metrology for mesoscale specimens in transmission electron microscope.

    Science.gov (United States)

    Han, Chang Wan; Ortalan, Volkan

    2015-09-01

    We have demonstrated a new electron tomography technique utilizing the secondary signals (secondary electrons and backscattered electrons) for ultra thick (a few μm) specimens. The Monte Carlo electron scattering simulations reveal that the amount of backscattered electrons generated by 200 and 300keV incident electrons is a monotonic function of the sample thickness and this causes the thickness contrast satisfying the projection requirement for the tomographic reconstruction. Additional contribution of the secondary electrons emitted from the edges of the specimens enhances the visibility of the surface features. The acquired SSI tilt series of the specimen having mesoscopic dimensions are successfully reconstructed verifying that this new technique, so called the secondary signal imaging electron tomography (SSI-ET), can directly be utilized for 3D structural analysis of mesoscale structures. Published by Elsevier Ltd.

  20. XRF and TXRF techniques for multi-element determination of trace elements in whole blood and human hair samples

    International Nuclear Information System (INIS)

    Khuder, A.; Karjou, J.; Sawan, M.Kh.; Bakir, M.A.

    2007-01-01

    XRF and TXRF were established as useful techniques for multi-element analysis of whole blood and human head hair samples. Direct-XRF with different collimation units and different X-ray excitation modes was successfully used for the determination of S, P, K, Ca, Fe, and Br elements in blood samples and K, Ca, Mn, Fe elements in human hair samples. Direct analysis by TXRF was used for the determination of Rb and Sr in digested blood and human hair samples, respectively, while, the co-precipitation method using APDC for TXRF analysis was used for the determination of Ni, Cu, Zn, and Pb elements in both matrices. As a result, the improved XRF and TXRF methods were applied for multi-element determination of elements in whole blood and human hair samples in non-occupational exposed population living in Damascus city. The mean concentrations of analyzed elements in both matrices were on the reported range values for non-occupational population in other countries. (author)

  1. XRF and TXRF techniques for multi-element determination of trace elements in whole blood and human hair samples

    International Nuclear Information System (INIS)

    Khuder, A.; Karjou, J.; Sawan, M.Kh.; Bakir, M.A.

    2008-01-01

    XRF and TXRF were established as useful techniques for multi-element analysis of whole blood and human head hair samples. Direct-XRF with different collimation units and different X-ray excitation modes was successfully used for the determination of S, P, K, Ca, Fe, and Br elements in blood samples and K, Ca, Mn, Fe elements in human hair samples. Direct analysis by TXRF was used for the determination of Rb and Sr in digested blood and human hair samples, respectively, while, the co-precipitation method using APDC for TXRF analysis was used for the determination of Ni, Cu, Zn, and Pb elements in both matrices. As a result, the improved XRF and TXRF methods were applied for multi-element determination of elements in whole blood and human hair samples in non-occupational exposed population living in Damascus city. The mean concentrations of analyzed elements in both matrices were on the reported range values for non-occupational population in other countries. (author)

  2. Seven-hour fluorescence in situ hybridization technique for enumeration of Enterobacteriaceae in food and environmental water sample.

    Science.gov (United States)

    Ootsubo, M; Shimizu, T; Tanaka, R; Sawabe, T; Tajima, K; Ezura, Y

    2003-01-01

    A fluorescent in situ hybridization (FISH) technique using an Enterobacteriaceae-specific probe (probe D) to target 16S rRNA was improved in order to enumerate, within a single working day, Enterobacteriaceae present in food and environmental water samples. In order to minimize the time required for the FISH procedure, each step of FISH with probe D was re-evaluated using cultured Escherichia coli. Five minutes of ethanol treatment for cell fixation and hybridization were sufficient to visualize cultured E. coli, and FISH could be performed within 1 h. Because of the difficulties in detecting low levels of bacterial cells by FISH without cultivation, a FISH technique for detecting microcolonies on membrane filters was investigated to improve the bacterial detection limit. FISH with probe D following 6 h of cultivation to grow microcolonies on a 13 mm diameter membrane filter was performed, and whole Enterobacteriaceae microcolonies on the filter were then detected and enumerated by manual epifluorescence microscopic scanning at magnification of x100 in ca 5 min. The total time for FISH with probe D following cultivation (FISHFC) was reduced to within 7 h. FISHFC can be applied to enumerate cultivable Enterobacteriaceae in food (above 100 cells g-1) and environmental water samples (above 1 cell ml-1). Cultivable Enterobacteriaceae in food and water samples were enumerated accurately within 7 h using the FISHFC method. A FISHFC method capable of evaluating Enterobacteriaceae contamination in food and environmental water within a single working day was developed.

  3. MUP, CEC-DES, STRADE. Codes for uncertainty propagation, experimental design and stratified random sampling techniques

    International Nuclear Information System (INIS)

    Amendola, A.; Astolfi, M.; Lisanti, B.

    1983-01-01

    The report describes the how-to-use of the codes: MUP (Monte Carlo Uncertainty Propagation) for uncertainty analysis by Monte Carlo simulation, including correlation analysis, extreme value identification and study of selected ranges of the variable space; CEC-DES (Central Composite Design) for building experimental matrices according to the requirements of Central Composite and Factorial Experimental Designs; and, STRADE (Stratified Random Design) for experimental designs based on the Latin Hypercube Sampling Techniques. Application fields, of the codes are probabilistic risk assessment, experimental design, sensitivity analysis and system identification problems

  4. Petrosal sinus sampling: technique and rationale.

    Science.gov (United States)

    Miller, D L; Doppman, J L

    1991-01-01

    Bilateral simultaneous sampling of the inferior petrosal sinuses is an extremely sensitive, specific, and accurate test for diagnosing Cushing disease and distinguishing between that entity and the ectopic ACTH syndrome. It is also valuable for lateralizing small hormone-producing adenomas within the pituitary gland. The inferior petrosal sinuses connect the cavernous sinuses with the ipsilateral internal jugular veins. The anatomy of the anastomoses between the inferior petrosal sinus, the internal jugular vein, and the venous plexuses at the base of the skull varies, but it is almost always possible to catheterize the inferior petrosal sinus. In addition, variations in size and anatomy are often present between the two inferior petrosal sinuses in a patient. Advance preparation is required for petrosal sinus sampling. Teamwork is a critical element, and each member of the staff should know what he or she will be doing during the procedure. The samples must be properly labeled, processed, and stored. Specific needles, guide wires, and catheters are recommended for this procedure. The procedure is performed with specific attention to the three areas of potential technical difficulty: catheterization of the common femoral veins, crossing the valve at the base of the left internal jugular vein, and selective catheterization of the inferior petrosal sinuses. There are specific methods for dealing with each of these areas. The sine qua non of correct catheter position in the inferior petrosal sinus is demonstration of reflux of contrast material into the ipsilateral cavernous sinus. Images must always be obtained to document correct catheter position. Special attention must be paid to two points to prevent potential complications: The patient must be given an adequate dose of heparin, and injection of contrast material into the inferior petrosal sinuses and surrounding veins must be done gently and carefully. When the procedure is performed as outlined, both inferior

  5. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    Directory of Open Access Journals (Sweden)

    Helena Prosen

    2014-05-01

    Full Text Available Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc. published in the last decade. Several innovative liquid-phase microextraction (LPME techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME, hollow fiber-liquid phase microextraction (HF-LPME, dispersive liquid-liquid microextraction (DLLME. Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  6. Applications of liquid-phase microextraction in the sample preparation of environmental solid samples.

    Science.gov (United States)

    Prosen, Helena

    2014-05-23

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several innovative liquid-phase microextraction (LPME) techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME). Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  7. Product-selective blot: a technique for measuring enzyme activities in large numbers of samples and in native electrophoresis gels

    International Nuclear Information System (INIS)

    Thompson, G.A.; Davies, H.M.; McDonald, N.

    1985-01-01

    A method termed product-selective blotting has been developed for screening large numbers of samples for enzyme activity. The technique is particularly well suited to detection of enzymes in native electrophoresis gels. The principle of the method was demonstrated by blotting samples from glutaminase or glutamate synthase reactions into an agarose gel embedded with ion-exchange resin under conditions favoring binding of product (glutamate) over substrates and other substances in the reaction mixture. After washes to remove these unbound substances, the product was measured using either fluorometric staining or radiometric techniques. Glutaminase activity in native electrophoresis gels was visualized by a related procedure in which substrates and products from reactions run in the electrophoresis gel were blotted directly into a resin-containing image gel. Considering the selective-binding materials available for use in the image gel, along with the possible detection systems, this method has potentially broad application

  8. En route vers la nano stabilisation de CLIC faisceau principale et focalisation finale

    CERN Document Server

    Artoos, K; Guinchard, M; Hauviller, Claude; Lackner, F; CERN. Geneva. TS Department

    2008-01-01

    Pour atteindre la luminosité voulue de CLIC, la taille transversale du faisceau doit être de l?ordre du nanomètre. Ceci nécessite une stabilité vibratoire des quadripôles du faisceau principal de 1 nm et même 0.1 nm pour les doublets de la focalisation finale. La nano technologie et la nano stabilisation sont des activités qui évoluent rapidement dans l?industrie et centres de recherche pour des applications très variées comme l?électronique, l?optique, la chimie voire la médecine. Cette présentation décrit les avancées techniques nécessaires pour atteindre l?objectif de CLIC et les projets et collaborations R&D prévus pour démontrer la faisabilité de la nano stabilisation de CLIC en 2010.

  9. Essai de caractérisation des phénomènes de stalking dans un contexte juridique et politique : radiogoniométrie et filature On characterization of stalking phenomena in a juridical and political context: radiogoniometry and tracking

    OpenAIRE

    Desurmont N.

    2010-01-01

    De nos jours il est devenu impossible d’étudier les filatures comme on les pratiquait avant la naissance de la triangulation et de la radiogoniométrie, les observations satellitaires, les communications radios, etc. En effet l’usage de la radiogoniométrie et de d’autres techniques par les services des renseignements généraux et les forces de l’ordre biaisent aujourd’hui fortement l’analyse des filatures de ces organes en ayant recours qu’à l’analyse topologique et la géocriminologie. Le prése...

  10. Microwave Heating of Synthetic Skin Samples for Potential Treatment of Gout Using the Metal-Assisted and Microwave-Accelerated Decrystallization Technique

    OpenAIRE

    Toker, Salih; Boone-Kukoyi, Zainab; Thompson, Nishone; Ajifa, Hillary; Clement, Travis; Ozturk, Birol; Aslan, Kadir

    2016-01-01

    Physical stability of synthetic skin samples during their exposure to microwave heating was investigated to demonstrate the use of the metal-assisted and microwave-accelerated decrystallization (MAMAD) technique for potential biomedical applications. In this regard, optical microscopy and temperature measurements were employed for the qualitative and quantitative assessment of damage to synthetic skin samples during 20 s intermittent microwave heating using a monomode microwave source (at 8 G...

  11. Determination of organically bound Tritium in environmental samples by application of the oxidizing plasma technique

    International Nuclear Information System (INIS)

    Strack, S.; Koenig, L.A.

    1981-12-01

    The low-temperature oxidizing plasma technique with a suitable system for trapping the water formed in the oxidation process can be used to determine T bound organically in low-level samples. First, the samples are freeze-dried and the tissue water obtained in this way is measured, after distillation, in a liquid scintillation spectrometer. The residual dry matter is ashed in the reactor chamber of the plasma system. Oxidation takes place at temperatures not exceeding 200 0 C in an oxygen flow of about 40 ml/min. The water of oxidation is collected in a cold trap installed behind the reactor chamber. A volume of about 10 ml of water is sufficient to measure the tritium activity without enrichment. The oxidation behavior of various organic materials has been tested. Some first results of T concentrations in tissue water and the organic dry matter from food and plant samples collected in the vicinity of the Nuclear Research Center are presented. The method has the advantage that a commercially available instrument can be used requiring only little additional equipment. Handling is much less dangerous and contamination effects by atmospheric T can be easily kept at a minimum. (orig./HP) [de

  12. Agroforesterie et alimentation des moutons au Mali | CRDI - Centre ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Review of pasture and fodder production and productivity for small ruminants in the Sahel. 53216. Rapports. Accroître la sécurité alimentaire en associant étroitement élevage, arbres et cultures par la pratique de l'agroforesterie au Mali : rapport technique final (1er mars 2011 - 1er septembre 2014). Téléchargez le PDF.

  13. General principles governing sampling and measurement techniques for monitoring radioactive effluents from nuclear facilities

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1978-01-01

    An explanation is given of the need to monitor the release of radioactive gases and liquid effluents from nuclear facilities, with particular emphasis on the ICRP recommendations and on the interest in this problem shown by the larger international organizations. This is followed by a description of the classes of radionuclides that are normally monitored in this way. The characteristics of monitoring 'in line' and 'by sample taking' are described; the disadvantages of in line monitoring and the problem of sample representativity are discussed. There follows an account of the general principles for measuring gaseous and liquid effluents that are applied in the techniques normally employed at nuclear facilities. Standards relating to the specifications for monitoring instruments are at present being devised by the International Electrotechnical Commission, and there are still major differences in national practices, at least as far as measurement thresholds are concerned. In conclusion, it is shown that harmonization of practices and standardization of equipment would probably help to make international relations in the field more productive. (author)

  14. Brief Exposures to the Taste of Ethanol (EtOH) and Quinine Promote Subsequent Acceptance of EtOH in a Paradigm that Minimizes Postingestive Consequences.

    Science.gov (United States)

    Loney, Gregory C; Meyer, Paul J

    2018-03-01

    Aversion to the orosensory properties of concentrated ethanol (EtOH) solutions is often cited as a primary barrier to initiation of drinking and may contribute to abstention. These aversive properties include gustatory processes which encompass both bitter-like taste qualities and trigeminal-mediated irritation. Chronic intermittent EtOH access (CIA) results in substantial and persistent increases in EtOH consumption, but the degree to which this facilitation involves sensory responding to EtOH and other bitter stimuli is currently undetermined. Long-Evans rats were given brief-access licking tests designed to examine the immediate, taste-guided assessment of the palatability of EtOH and quinine solutions. Rats were assessed once in a naïve state and again following previous brief-access exposure, or following 4 weeks of CIA. The relationship between the sensitivity to the aversive orosensory properties of EtOH and quinine following EtOH access and the impact of antecedent quinine exposure on the acceptance of EtOH were determined in 2 parallel studies. Both brief access to EtOH and 4-week CIA resulted in substantial rightward shifts in the concentration-response function of brief-access EtOH licking, indicating that EtOH exposure increased acceptance of the taste of EtOH. The initial sensitivity to the aversive orosensory properties of EtOH and quinine was positively correlated in naïve rats, such that rats that were initially more accepting of quinine were also more accepting of EtOH. Rats that sampled quinine immediately prior to tasting EtOH exhibited successive positive contrast in that they were more accepting of highly concentrated EtOH, relative to a water-control group. Increased EtOH acceptance following exposure is, at least in part, facilitated by a decrease in its aversive sensory properties. Both long- and short-term access increase the palatability of the taste of EtOH in brief-access licking tests. Moreover, the sensitivity to the bitterness of

  15. The alkali halide disk technique in infra-red spectrometry : Anomalous behaviour of some samples dispersed in alkali halide disks

    NARCIS (Netherlands)

    Tolk, A.

    1961-01-01

    Some difficulties encountered in the application of the alkali halide disk technique in infra-red spectrometry are discussed. Complications due to interaction of the sample with the alkali halide have been studied experimentally. It was found that the anomalous behaviour of benzoic acid, succinic

  16. Localized damage in soft rock: experiments with field measurement techniques

    International Nuclear Information System (INIS)

    Nguyen, T.L.

    2011-01-01

    The research presented in this thesis concerns, firstly, an experimental study on the process of fracture in uniaxial compression of rock samples containing narrow, rectilinear notches inclined with respect to the axis of loading. Secondly, we study the evolution of shear strain localisation towards fracturing and failure in specimens of the same materials with a particular geometry, involving two rounded notches. This geometry, inspired by the work of Meuwissen et al. (1998) for tension tests on metals, promotes the localisation of shear strain in simple compression before fracture. Two different materials were studied: a natural rock of volcanic origin (Neapolitan Tuff) and an artificial 'roc' (CPIR09). In the studies presented, three full-field measurement techniques have been employed in combination: (i) the Digital Image Correlation (DIC), for measurement of kinematic fields at a sample's surface; (ii)acoustic Emission measurements (AE) and AE source location, to follow the evolution of damage in samples during loading; (iii) X-ray tomography (pre-and post-mortem studies), to characterise preexisting defects and discontinuities in the specimens and to better understand the fracturing in 3D. (author)

  17. Comparative study of modern extraction techniques for the determination of environmental samples (M14)

    International Nuclear Information System (INIS)

    Gfrerer, M.; Lankmayr, E.

    2002-01-01

    Full text: The aim of any extraction method in analytical chemistry is, to effectively separate the analytes from the matrix. The whole step should be fast and quantitative with minimal solvent and time required. The classical Soxhlet extraction usually requires large volumes (up to 200 ml) of solvent to be refluxed through the solid samples for several hours. Therefore, in the last decades, alternatives for this extraction method have been presented and investigated such as ultrasonic extraction (UE), supercritical fluid extraction (SFE), accelerated solvent extraction (ASE), microwave-assisted extraction (MAE) and fluidized-bed extraction (FBE). The actual choice for analytical application is frequently the initial capital cost, operating costs, simplicity of operation, amount of organic solvent required and sample throughput. Since sample preparation is a critical step in the analytical cycle, special care has to be taken for an accurate choice and optimization of extraction techniques and clean-up procedures. Therefore, MAE and FBE were investigated for their influential extraction parameters and these parameters were optimized for the extraction of organochlorine biocides, polychlorinated biphenyls and polycyclic aromatic hydrocarbons from environmental matrices like soil, sediment and sewage sludge. The extraction yields were compared with those obtained by Soxhlet extraction performed following DIN-methods. Finally, the optimized modern methods were validated by systematic experiments with certified reference materials. Refs. 3 (author)

  18. Référentiel aspad D83 contrôle d'accès : document technique pour la conception et l'installation

    CERN Document Server

    2012-01-01

    Le référentiel APSAD D83 a pour objectif d’accompagner les utilisateurs, prescripteurs, concepteurs et installateurs dans la conduite d'un projet de contrôle des accès physiques. Qu'il s'agisse d'éviter les pénétrations de personnes pouvant constituer une menace ou de filtrer les flux, il définit tous les paramètres à prendre en compte pour formuler un choix technologique adapté aux impératifs de sûreté du site et à son budget. La méthode utilisée comprend une analyse des besoins et des risques, la conception et la réalisation du système de contrôle d'accès, la formation des utilisateurs et la maintenance. Cette édition de novembre 2012 du référentiel APSAD D83 annule et remplace l’édition d’octobre 2005 du référentiel CNPP 5083.

  19. The use of ICP-MS and LA-ICP-MS techniques for uranium analysis in real-life swipe samples for safeguards purposes

    Energy Technology Data Exchange (ETDEWEB)

    Pestana, Rafael C.B.; Sarkis, Jorge E.S.; Carvalho, Elita F.U., E-mail: rcbpestana@gmail.com, E-mail: jesarkis@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Abreu Junior, Cassio H. [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)

    2013-07-01

    Environmental swipe sampling for safeguards purposes is a powerful tool to detect undeclared materials and activities, and has been used by the International Atomic Energy Agency since 1997. This work describes the utilization of the inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for determining uranium isotopic ratios in a real-life swipe samples collected in a conversion plant at IPEN/CNEN, Brazil. Uncertainties were estimated by following the International Organization for Standardization - Guide to the Expression of Uncertainties in Measurement (ISO GUM), with a confidence level of 95%. The major uncertainties percentage for n({sup 235}U)/n({sup 238}U) ratio for ICP-MS was 3% and for LA-ICP-MS was 30% The values of uranium isotopic ratios obtained for each technique demonstrate the viability of these analytical techniques as an alternative tool for uranium analysis in swipe samples for safeguards purposes. (author)

  20. The use of ICP-MS and LA-ICP-MS techniques for uranium analysis in real-life swipe samples for safeguards purposes

    International Nuclear Information System (INIS)

    Pestana, Rafael C.B.; Sarkis, Jorge E.S.; Carvalho, Elita F.U.; Abreu Junior, Cassio H.

    2013-01-01

    Environmental swipe sampling for safeguards purposes is a powerful tool to detect undeclared materials and activities, and has been used by the International Atomic Energy Agency since 1997. This work describes the utilization of the inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for determining uranium isotopic ratios in a real-life swipe samples collected in a conversion plant at IPEN/CNEN, Brazil. Uncertainties were estimated by following the International Organization for Standardization - Guide to the Expression of Uncertainties in Measurement (ISO GUM), with a confidence level of 95%. The major uncertainties percentage for n( 235 U)/n( 238 U) ratio for ICP-MS was 3% and for LA-ICP-MS was 30% The values of uranium isotopic ratios obtained for each technique demonstrate the viability of these analytical techniques as an alternative tool for uranium analysis in swipe samples for safeguards purposes. (author)