WorldWideScience

Sample records for sampling adc readout

  1. An FPGA-based sampling-ADC readout for the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Muellers, Johannes [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Marciniewski, Pawel [Angstroemlaboratoriet, Uppsala (Sweden); Collaboration: CBELSA/TAPS-Collaboration

    2015-07-01

    The CBELSA/TAPS experiment at the electron accelerator ELSA (Bonn) investigates the photoproduction of mesons off protons and neutrons. Presently the readout of the CsI(Tl)-crystals of the Crystal Barrel calorimeter is being upgraded from a PIN-diode readout to an APD readout to create a fast signal for first-level-triggering. This will increase the trigger efficiency especially for final states with only neutral particles substantially. To increase the possible data readout rate, which is currently limited by the digitization stage (LeCroy QDC 1885F) to ∼ 2 kHz, the implementation of a new Sampling-ADC (SADC) readout is being prepared. Based on the 64-channel PANDA-SADC, the CB-SADC design was modified and adapted to the needs of the CBELSA/TAPS experiment. It offers 64 channels in one NIM module, together with modular analog or FPGA-based digital shaping. The data transfer will be realized by two standard gigabit links. Using an FPGA together with SADCs provides a multitude of possibilities for online feature extraction, such as the determination of the energy deposited in the crystal, TDC capabilities and pile-up detection and recovery.

  2. An FPGA-based Sampling-ADC readout for the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Muellers, Johannes [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Marciniewski, Pawel [Angstroemlaboratoriet, Uppsala (Sweden); Collaboration: CBELSA/TAPS-Collaboration

    2016-07-01

    The CBELSA/TAPS experiment at the electron accelerator ELSA (Bonn) investigates the photoproduction of mesons off protons and neutrons. The Crystal Barrel Calorimeter has been upgraded replacing its photodiode readout by APDs, which allows the integration of the calorimeter into the first level trigger. Since the possible DAQ rate is currently limited by the digitization stage (LeCroy QDC1885F) to ∼ 2 kHz, the implementation of a new Sampling-ADC (SADC) readout is the second important step in the upgrade of the detector system. Based on the 64-channel PANDA-SADC, the design was modified, adapting it to the needs of the CBELSA/TAPS experiment. The CB-SADC offers 64 channels in one NIM module with up to 14 bit rate at 125 MHz, accompanied by a modular analog input stage and power supply. Data processing and reduction are realized with Kintex7 FPGAs. Readout is possible via gigabit ethernet links. Using an FPGA provides a multitude of possibilities for online feature extraction, such as the determination of the energy deposited in the crystal, TDC capabilities and pile-up detection and recovery. The SADC development is discussed, and first measurements performed in comparison to the presently used LeCroy QDC are presented.

  3. Area-efficient readout with 14-bit SAR-ADC for CMOS image sensors

    Directory of Open Access Journals (Sweden)

    Aziza Sassi Ben

    2016-01-01

    Full Text Available This paper proposes a readout design for CMOS image sensors. It has been squeezed into a 7.5um pitch under a 0.28um 1P3M technology. The ADC performs one 14-bit conversion in only 1.5us and targets a theoretical DNL feature about +1.3/-1 at 14-bit accuracy. Correlated Double Sampling (CDS is performed both in the analog and digital domains to preserve the image quality.

  4. A low-power small-area ADC array for IRFPA readout

    Science.gov (United States)

    Zhong, Shengyou; Yao, Libin

    2013-09-01

    The readout integrated circuit (ROIC) is a bridge between the infrared focal plane array (IRFPA) and image processing circuit in an infrared imaging system. The ROIC is the first part of signal processing circuit and connected to detectors directly, so its performance will greatly affect the detector or even the whole imaging system performance. With the development of CMOS technologies, it's possible to digitalize the signal inside the ROIC and develop the digital ROIC. Digital ROIC can reduce complexity of the whole system and improve the system reliability. More importantly, it can accommodate variety of digital signal processing techniques which the traditional analog ROIC cannot achieve. The analog to digital converter (ADC) is the most important building block in the digital ROIC. The requirements for ADCs inside the ROIC are low power, high dynamic range and small area. In this paper we propose an RC hybrid Successive Approximation Register (SAR) ADC as the column ADC for digital ROIC. In our proposed ADC structure, a resistor ladder is used to generate several voltages. The proposed RC hybrid structure not only reduces the area of capacitor array but also releases requirement for capacitor array matching. Theory analysis and simulation show RC hybrid SAR ADC is suitable for ADC array applications

  5. A Low Power Rad-Hard ADC for the KID Readout Electronics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposal aims to develop a radiation hardened analog-to-digital converter (ADC) required for the Kinetic Inductance Detector (KID) readout electronics. KIDs are...

  6. Optimal CCD readout by digital correlated double sampling

    Science.gov (United States)

    Alessandri, C.; Abusleme, A.; Guzman, D.; Passalacqua, I.; Alvarez-Fontecilla, E.; Guarini, M.

    2016-01-01

    Digital correlated double sampling (DCDS), a readout technique for charge-coupled devices (CCD), is gaining popularity in astronomical applications. By using an oversampling ADC and a digital filter, a DCDS system can achieve a better performance than traditional analogue readout techniques at the expense of a more complex system analysis. Several attempts to analyse and optimize a DCDS system have been reported, but most of the work presented in the literature has been experimental. Some approximate analytical tools have been presented for independent parameters of the system, but the overall performance and trade-offs have not been yet modelled. Furthermore, there is disagreement among experimental results that cannot be explained by the analytical tools available. In this work, a theoretical analysis of a generic DCDS readout system is presented, including key aspects such as the signal conditioning stage, the ADC resolution, the sampling frequency and the digital filter implementation. By using a time-domain noise model, the effect of the digital filter is properly modelled as a discrete-time process, thus avoiding the imprecision of continuous-time approximations that have been used so far. As a result, an accurate, closed-form expression for the signal-to-noise ratio at the output of the readout system is reached. This expression can be easily optimized in order to meet a set of specifications for a given CCD, thus providing a systematic design methodology for an optimal readout system. Simulated results are presented to validate the theory, obtained with both time- and frequency-domain noise generation models for completeness.

  7. A 12-bit SAR ADC integrated on a multichannel silicon drift detector readout IC

    Energy Technology Data Exchange (ETDEWEB)

    Schembari, F., E-mail: filippo.schembari@polimi.it [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, via Golgi 40, 20133 Milano (Italy); INFN, Sezione di Milano, via Celoria 16, 20133 Milano (Italy); Bellotti, G.; Fiorini, C. [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, via Golgi 40, 20133 Milano (Italy); INFN, Sezione di Milano, via Celoria 16, 20133 Milano (Italy)

    2016-07-11

    A 12-bit analog-to-digital converter (ADC) addressed to Silicon-Drift Detectors (SDDs) multichannel readout ASICs for X- and gamma-ray applications is presented. Aiming at digitizing output multiplexed data from the upstream analog filters banks, the converter must ensure 11-bit accuracy and a sampling frequency of about 5 MS/s. The ADC architecture is the charge-redistribution (CR) successive-approximation register (SAR). A fully differential topology has also been chosen for better rejection of common-mode noise and disturbances. The internal DAC is made of binary-scaled capacitors, whose bottom plates are switched by the SAR logic to perform the binary search of the analog input value by means of the monotonic switching scheme. The A/D converter is integrated on SFERA, a multichannel ASIC fabricated in a standard CMOS 0.35 μm 3.3 V technology and it occupies an area of 0.42 mm{sup 2}. Simulated static performance shows monotonicity over the whole input–output characteristic. The description of the circuit topology and of inner blocks architectures together with the experimental characterization is here presented. - Highlights: • X- and γ-ray spectroscopy front-ends need to readout a high number of detectors. • Design efforts are increasingly oriented to compact and low-power ASICs. • A possible solution is the on-chip integration of the analog-to-digital converter. • A 12-bit CR successive-approximation-register ADC has been developed. • It is a suitable candidate as the digitizer to be integrated in multichannel ASICs.

  8. An FPGA-based slowcontrol module and a baseline shifting extension card for the sampling-ADC readout of the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Urff, Georg; Poller, Timo [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Collaboration: CBELSA/TAPS-Collaboration

    2016-07-01

    At the electron accelerator ELSA (Bonn) the CBELSA/TAPS experiment investigates the photoproduction of mesons off protons and neutrons. The CsI(Tl)-crystals of the Crystal Barrel calorimeter are being upgraded from a PIN-diode readout to an APD readout. In the context of this upgrade, an FPGA-based Sampling-ADC (SADC) is presently being developed (HK 304). A Slow-control Module for the SADC with TCP/Telnet access has been developed on the basis of a Spartan6 FPGA. Control and monitoring of the SADC's power supply as well as control of parameters of the analog and digital data processing in the SADC is realized via PMBus/I{sup 2}C. The prototype as well as an overview of its functionality will be presented. In order to fully utilize the dynamic input range of the SADCs, an interfacing extension board was designed. It receives the differential signal generated by previous amplification stages and adds an individual DC offset voltage to each channel supplied by a digital-to-analog converter. The circuit and the used techniques as well as simulations and measurements are presented.

  9. A fast ADC system for silicon μstrips readout

    International Nuclear Information System (INIS)

    Inzani, P.; Pedrini, D.; Sala, S.

    1986-01-01

    A new fast ADC module has been designed. It is part of a large readout system for a high resolution vertex detector consisting of 12 silicon microstrip planes with more than 8000 channels. The module employs a set of monolithic gated integrators on input (LeCroy MIQ 401) multiplexed on a single 8 bit FADC (Thompson EFX8308). A built-in preprocessing, performed through look up tables, accomplishes equalization and reduction of the data and makes high level trigger feasible. As an additional feature, fast histogramming of all the channels in parallel has been made possible with an internal memory. Special care has been paid to realize a low cost and low power consumption system

  10. PDC: A wire chamber cathode read-out on 6-bit fast ADC

    Energy Technology Data Exchange (ETDEWEB)

    De Giorgi, M; Gasparini, F; Meneguzzo, A T; Pitacco, G [Istituto Nazionale di Fisica Nucleare, Padua (Italy); Padua Univ. (Italy). Ist. di Fisica)

    1984-06-01

    A read-out for MWPC and drift chamber is presented in which the coordinate along the sense wires is obtained by measuring the centre of gravity (CoG) of the charge induced on cathode strips or pads. The peak value of the signals coming from subsets of 8-pad cathodes are recorded by a parallel sample and hold, strobed by their own OR, and then serially digitized by one 6-bit fast ADC (FADC). The basic module of the system is a peak detector and converter (PDC) built in CAMAC cards, which could be an interesting approach to the analog signal acquisition of large particle detectors. The system has been designed to equip the central detector in an experiment at the CERN LEAR facility. A prototype of a card will be described and the results of some tests will be presented.

  11. VMEbus interface for spectroscopy ADCs

    International Nuclear Information System (INIS)

    Jaeaeskelaeinen, M.

    1987-01-01

    A high performance VMEbus interface for spectroscopy ADCs and other similar devices used in nuclear spectroscopy coincidence experiments has been developed. This new module can be used to interface existing spectroscopy ADCs with fast parallel data transfer into the industry standard multiprocessor VMEbus. The unit provides a fast direct readout of the ADC data into the VMEbus memory. The interface also has built-in capabilities that enable it to be used in coincidence experiments for slow data timing and ADC pattern recognition. (orig.)

  12. The front-end data conversion and readout electronics for the CMS ECAL upgrade

    CERN Document Server

    Mazza, Gianni

    2017-01-01

    The High Luminosity LHC (HL-LHC) will require a significant upgrade of the readout electronics for the CMS Electromagnetic Calorimeter (ECAL). The Very Front-End (VFE) output signal will be sampled at 160 MS/s (i.e. four times the current sampling rate) with 13 bit resolution. Therefore, a high-speed, high-resolution ADC is required. Moreover, each readout channel will produce 2.08 Gb/s, thus requiring fast data transmission circuitry. A new readout architecture, based on two 12 bit, 160 MS/s ADCs, lossless data compression algorithms and fast serial links have been developed for the ECAL upgrade. These functions will be integrated in a single ASIC which is currently under design in a commercial CMOS 65 nm technology using radiation damage mitigation techniques.

  13. Read-out and calibration of a tile calorimeter for ATLAS

    International Nuclear Information System (INIS)

    Tardell, S.

    1997-06-01

    The read-out and calibration of scintillating tiles hadronic calorimeter for ATLAS is discussed. Tests with prototypes of FERMI, a system of read-out electronics based on a dynamic range compressor reducing the dynamic range from 16 to 10 bits and a 40 MHz 10 bits sampling ADC, are presented. In comparison with a standard charge integrating read-out improvements in the resolution of 1% in the constant term are obtained

  14. Noise Reduction Effect of Multiple-Sampling-Based Signal-Readout Circuits for Ultra-Low Noise CMOS Image Sensors

    Directory of Open Access Journals (Sweden)

    Shoji Kawahito

    2016-11-01

    Full Text Available This paper discusses the noise reduction effect of multiple-sampling-based signal readout circuits for implementing ultra-low-noise image sensors. The correlated multiple sampling (CMS technique has recently become an important technology for high-gain column readout circuits in low-noise CMOS image sensors (CISs. This paper reveals how the column CMS circuits, together with a pixel having a high-conversion-gain charge detector and low-noise transistor, realizes deep sub-electron read noise levels based on the analysis of noise components in the signal readout chain from a pixel to the column analog-to-digital converter (ADC. The noise measurement results of experimental CISs are compared with the noise analysis and the effect of noise reduction to the sampling number is discussed at the deep sub-electron level. Images taken with three CMS gains of two, 16, and 128 show distinct advantage of image contrast for the gain of 128 (noise(median: 0.29 e−rms when compared with the CMS gain of two (2.4 e−rms, or 16 (1.1 e−rms.

  15. The front-end data conversion and readout electronics for the CMS ECAL upgrade

    Science.gov (United States)

    Mazza, G.; Cometti, S.

    2018-03-01

    The High Luminosity LHC (HL-LHC) will require a significant upgrade of the readout electronics for the CMS Electromagnetic Calorimeter (ECAL). The Very Front-End (VFE) output signal will be sampled at 160 MS/s (i.e. four times the current sampling rate) with a 13 bits resolution. Therefore, a high-speed, high-resolution ADC is required. Moreover, each readout channel will produce 2.08 Gb/s, thus requiring a fast data transmission circuitry. A new readout architecture, based on two 12 bit, 160 MS/s ADCs, lossless data compression algorithms and fast serial links have been developed for the ECAL upgrade. These functions will be integrated in a single ASIC which is currently under design in a commercial CMOS 65 nm technology using radiation damage mitigation techniques.

  16. Evaluation of Multi-Channel ADCs for Gamma-Ray Spectroscopy

    Science.gov (United States)

    Tan, Hui; Hennig, Wolfgang; Walby, Mark D.; Breus, Dimitry; Harris, Jackson

    2013-04-01

    As nuclear physicists increasingly design large scale experiments with hundreds or thousands of detector channels, there are growing needs for high density readout electronics with good timing and energy resolution that at the same time offer lower cost per channel compared to existing commercial solutions. Recent improvements in the design of commercial analog to digital converters (ADCs) have resulted in a variety of multi-channel ADCs that are natural choice for designing such high density readout modules. However, multi-channel ADCs typically are designed for medical imaging/ultrasound applications and therefore are not rated for their spectroscopic characteristics. In this work, we evaluated the gamma-ray spectroscopic performance of several multi-channel ADCs, including their energy resolution, nonlinearity, and timing resolution. Some of these ADCs demonstrated excellent energy resolution, 2.66% FWHM at 662 keV with a LaBr3 or 1.78 keV FWHM at 1332.5 keV with a high purity germanium (HPGe) detector, and sub-nanosecond timing resolution with LaBr 3. We present results from these measurements to illustrate their suitability for gamma-ray spectroscopy.

  17. Evaluation of Fermi read-out of the Atlas Tilecal prototype

    International Nuclear Information System (INIS)

    Ajaltouni, Z.; Alifanov, A.

    1998-01-01

    Prototypes of the FERMI system have been used to read out a prototype of the ATLAS hadron calorimeter in a beam test at the CERN SPS. The FERMI read-out system, using a compressor and a sampling ADC, is compared to a standard charge integrating read-out by measuring the energy resolution of the calorimeter separately with the two systems on the same events. Signal processing techniques have been designed to optimize the treatment of FERMI data. The resulting energy resolution is better than the one obtained with the standard read-out. (orig.)

  18. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Ingebretsen, F.; Holt, K.; Skaali, B.

    1983-04-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configuration of singles and multiparameter events from 1 up to 15 ADC's in one crate

  19. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Holt, K.; Ingebretsen, F.; Skaali, B.

    1983-01-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configurations of singles and multiparameter events from 1 up to 15 ADC's in one crate

  20. Fast Imaging Detector Readout Circuits with In-Pixel ADCs for Fourier Transform Imaging Spectrometers

    Science.gov (United States)

    Rider, D.; Blavier, J-F.; Cunningham, T.; Hancock, B.; Key, R.; Pannell, Z.; Sander, S.; Seshadri, S.; Sun, C.; Wrigley, C.

    2011-01-01

    Focal plane arrays (FPAs) with high frame rates and many pixels benefit several upcoming Earth science missions including GEO-CAPE, GACM, and ACE by enabling broader spatial coverage and higher spectral resolution. FPAs for the PanFTS, a high spatial resolution Fourier transform spectrometer and a candidate instrument for the GEO-CAPE mission are the focus of the developments reported here, but this FPA technology has the potential to enable a variety of future measurements and instruments. The ESTO ACT Program funded the developed of a fast readout integrated circuit (ROIC) based on an innovative in-pixel analog-to-digital converter (ADC). The 128 X 128 pixel ROIC features 60 ?m pixels, a 14-bit ADC in each pixel and operates at a continuous frame rate of 14 kHz consuming only 1.1 W of power. The ROIC outputs digitized data completely eliminating the bulky, power consuming signal chains needed by conventional FPAs. The 128 X 128 pixel ROIC has been fabricated in CMOS and tested at the Jet Propulsion Laboratory. The current version is designed to be hybridized with PIN photodiode arrays via indium bump bonding for light detection in the visible and ultraviolet spectral regions. However, the ROIC design incorporates a small photodiode in each cell to permit detailed characterization of the ROICperformance without the need for hybridization. We will describe the essential features of the ROIC design and present results of ROIC performance measurements.

  1. Optical transmission modules for multi-channel superconducting quantum interference device readouts

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin-Mok, E-mail: jmkim@kriss.re.kr; Kwon, Hyukchan; Yu, Kwon-kyu; Lee, Yong-Ho; Kim, Kiwoong [Brain Cognition Measurement Center, Korea Research Institute of Standards and Science, Daejeon 305-600 (Korea, Republic of)

    2013-12-15

    We developed an optical transmission module consisting of 16-channel analog-to-digital converter (ADC), digital-noise filter, and one-line serial transmitter, which transferred Superconducting Quantum Interference Device (SQUID) readout data to a computer by a single optical cable. A 16-channel ADC sent out SQUID readouts data with 32-bit serial data of 8-bit channel and 24-bit voltage data at a sample rate of 1.5 kSample/s. A digital-noise filter suppressed digital noises generated by digital clocks to obtain SQUID modulation as large as possible. One-line serial transmitter reformed 32-bit serial data to the modulated data that contained data and clock, and sent them through a single optical cable. When the optical transmission modules were applied to 152-channel SQUID magnetoencephalography system, this system maintained a field noise level of 3 fT/√Hz @ 100 Hz.

  2. Integrating a sampling oscilloscope card and spectroscopy ADCs in a data acquisition system

    CERN Document Server

    Maartensson, L

    2001-01-01

    A high-rate sampling oscilloscope card has been integrated into an existing data acquisition system for spectroscopy ADCs. Experiments where pulse-shape analyses are important have then been made possible. Good performance characteristics of the integrated system have been achieved. Spectroscopy ADC data together with pulse-shape data sampled 512 times at 100 MHz are saved to hard disk at event rates up to about 1 kHz with low dead time losses.

  3. Readout electronics development for the ATLAS silicon tracker

    International Nuclear Information System (INIS)

    Borer, K.; Beringer, J.; Anghinolfi, F.; Aspell, P.; Chilingarov, A.; Jarron, P.; Heijne, E.H.M.; Santiard, J.C.; Verweij, H.; Goessling, C.; Lisowski, B.; Reichold, A.; Bonino, R.; Clark, A.G.; Kambara, H.; La Marra, D.; Leger, A.; Wu, X.; Richeux, J.P.; Taylor, G.N.; Fedotov, M.; Kuper, E.; Velikzhanin, Yu.; Campbell, D.; Murray, P.; Seller, P.

    1995-01-01

    We present the status of the development of the readout electronics for the large area silicon tracker of the ATLAS experiment at the LHC, carried out by the CERN RD2 project. Our basic readout concept is to integrate a fast amplifier, analog memory, sparse data scan circuit and analog-to-digital convertor (ADC) on a single VLSI chip. This architecture will provide full analog information of charged particle hits associated unambiguously to one LHC beam crossing, which is expected to be at a frequency of 40 MHz. The expected low occupancy of the ATLAS inner silicon detectors allows us to use a low speed (5 MHz) on-chip ADC with a multiplexing scheme. The functionality of the fast amplifier and analog memory have been demonstrated with various prototype chips. Most recently we have successfully tested improved versions of the amplifier and the analog memory. A piecewise linear ADC has been fabricated and performed satisfactorily up to 5 MHz. A new chip including amplifier, analog memory, memory controller, ADC, and data buffer has been designed and submitted for fabrication and will be tested on a prototype of the ATLAS silicon tracker module with realistic electrical and mechanical constraints. (orig.)

  4. A radiation-hard dual-channel 12-bit 40 MS/s ADC prototype for the ATLAS liquid argon calorimeter readout electronics upgrade at the CERN LHC

    Energy Technology Data Exchange (ETDEWEB)

    Kuppambatti, J. [Columbia University, Dept. of Electrical Engineering, New York, NY (United States); Ban, J. [Columbia University, Nevis Laboratories, Irvington, NY (United States); Andeen, T., E-mail: tandeen@utexas.edu [Columbia University, Nevis Laboratories, Irvington, NY (United States); Brown, R.; Carbone, R. [Columbia University, Nevis Laboratories, Irvington, NY (United States); Kinget, P. [Columbia University, Dept. of Electrical Engineering, New York, NY (United States); Brooijmans, G.; Sippach, W. [Columbia University, Nevis Laboratories, Irvington, NY (United States)

    2017-05-21

    The readout electronics upgrade for the ATLAS Liquid Argon Calorimeters at the CERN Large Hadron Collider requires a radiation-hard ADC. The design of a radiation-hard dual-channel 12-bit 40 MS/s pipeline ADC for this use is presented. The design consists of two pipeline A/D channels each with four Multiplying Digital-to-Analog Converters followed by 8-bit Successive-Approximation-Register analog-to-digital converters. The custom design, fabricated in a commercial 130 nm CMOS process, shows a performance of 67.9 dB SNDR at 10 MHz for a single channel at 40 MS/s, with a latency of 87.5 ns (to first bit read out), while its total power consumption is 50 mW/channel. The chip uses two power supply voltages: 1.2 and 2.5 V. The sensitivity to single event effects during irradiation is measured and determined to meet the system requirements.

  5. A positron emission tomograph based on LSO-APD modules with a sampling ADC read-out system for a students' advanced laboratory course

    International Nuclear Information System (INIS)

    Schneider, Florian R.; Mann, Alexander B.; Technische Univ. Muenchen, Klinikum rechts der Isar; Konorov, Igor; Paul, Stephan; Delso, Gaspar; Ziegler, Sibylle I.

    2012-01-01

    A one-day laboratory course on positron emission tomography (PET) for the education of physics students and PhD students in medical physics has been set up. In the course, the physical background and the principles of a PET scanner are introduced. Course attendees set the system in operation, calibrate it using a 22 Na point source and reconstruct different source geometries filled with 18 F. The PET scanner features an individual channel read-out of 96 lutetium oxyorthosilicate (LSO) scintillator crystals coupled to avalanche photodiodes (APD). The analog data of each APD are digitized by fast sampling analog to digital converters (SADC) and processed within field programmable gate arrays (FPGA) to extract amplitudes and time stamps. All SADCs are continuously sampling with a precise rate of 80 MHz, which is synchronous for the whole system. The data is transmitted via USB to a Linux PC, where further processing and the image reconstruction are performed. The course attendees get an insight into detector techniques, modern read-out electronics, data acquisition and PET image reconstruction. In addition, a short introduction to some common software applications used in particle and high energy physics is part of the course. (orig.)

  6. A positron emission tomograph based on LSO-APD modules with a sampling ADC read-out system for a students' advanced laboratory course.

    Science.gov (United States)

    Schneider, Florian R; Mann, Alexander B; Konorov, Igor; Delso, Gaspar; Paul, Stephan; Ziegler, Sibylle I

    2012-06-01

    A one-day laboratory course on positron emission tomography (PET) for the education of physics students and PhD students in medical physics has been set up. In the course, the physical background and the principles of a PET scanner are introduced. Course attendees set the system in operation, calibrate it using a (22)Na point source and reconstruct different source geometries filled with (18)F. The PET scanner features an individual channel read-out of 96 lutetium oxyorthosilicate (LSO) scintillator crystals coupled to avalanche photodiodes (APD). The analog data of each APD are digitized by fast sampling analog to digital converters (SADC) and processed within field programmable gate arrays (FPGA) to extract amplitudes and time stamps. All SADCs are continuously sampling with a precise rate of 80MHz, which is synchronous for the whole system. The data is transmitted via USB to a Linux PC, where further processing and the image reconstruction are performed. The course attendees get an insight into detector techniques, modern read-out electronics, data acquisition and PET image reconstruction. In addition, a short introduction to some common software applications used in particle and high energy physics is part of the course. Copyright © 2011. Published by Elsevier GmbH.

  7. A positron emission tomograph based on LSO-APD modules with a sampling ADC read-out system for a students' advanced laboratory course

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Florian R.; Mann, Alexander B. [Technische Univ. Muenchen, Garching (Germany). Physik-Department E18; Technische Univ. Muenchen, Klinikum rechts der Isar (Germany). Nuklearmedizinische Klinik und Poliklinik; Konorov, Igor; Paul, Stephan [Technische Univ. Muenchen, Garching (Germany). Physik-Department E18; Delso, Gaspar; Ziegler, Sibylle I. [Technische Univ. Muenchen, Klinikum rechts der Isar (Germany). Nuklearmedizinische Klinik und Poliklinik

    2012-07-01

    A one-day laboratory course on positron emission tomography (PET) for the education of physics students and PhD students in medical physics has been set up. In the course, the physical background and the principles of a PET scanner are introduced. Course attendees set the system in operation, calibrate it using a {sup 22}Na point source and reconstruct different source geometries filled with {sup 18}F. The PET scanner features an individual channel read-out of 96 lutetium oxyorthosilicate (LSO) scintillator crystals coupled to avalanche photodiodes (APD). The analog data of each APD are digitized by fast sampling analog to digital converters (SADC) and processed within field programmable gate arrays (FPGA) to extract amplitudes and time stamps. All SADCs are continuously sampling with a precise rate of 80 MHz, which is synchronous for the whole system. The data is transmitted via USB to a Linux PC, where further processing and the image reconstruction are performed. The course attendees get an insight into detector techniques, modern read-out electronics, data acquisition and PET image reconstruction. In addition, a short introduction to some common software applications used in particle and high energy physics is part of the course. (orig.)

  8. Reproducibility of brain ADC histograms

    International Nuclear Information System (INIS)

    Steens, S.C.A.; Buchem, M.A. van; Admiraal-Behloul, F.; Schaap, J.A.; Hoogenraad, F.G.C.; Wheeler-Kingshott, C.A.M.; Tofts, P.S.; Cessie, S. le

    2004-01-01

    The aim of this study was to assess the effect of differences in acquisition technique on whole-brain apparent diffusion coefficient (ADC) histogram parameters, as well as to assess scan-rescan reproducibility. Diffusion-weighted imaging (DWI) was performed in 7 healthy subjects with b-values 0-800, 0-1000, and 0-1500 s/mm 2 and fluid-attenuated inversion recovery (FLAIR) DWI with b-values 0-1000 s/mm 2 . All sequences were repeated with and without repositioning. The peak location, peak height, and mean ADC of the ADC histograms and mean ADC of a region of interest (ROI) in the white matter were compared using paired-sample t tests. Scan-rescan reproducibility was assessed using paired-sample t tests, and repeatability coefficients were reported. With increasing maximum b-values, ADC histograms shifted to lower values, with an increase in peak height (p<0.01). With FLAIR DWI, the ADC histogram shifted to lower values with a significantly higher, narrower peak (p<0.01), although the ROI mean ADC showed no significant differences. For scan-rescan reproducibility, no significant differences were observed. Different DWI pulse sequences give rise to different ADC histograms. With a given pulse sequence, however, ADC histogram analysis is a robust and reproducible technique. Using FLAIR DWI, the partial-voluming effect of cerebrospinal fluid, and thus its confounding effect on histogram analyses, can be reduced

  9. The AMS silicon tracker readout, performance results with minimum ionizing particles

    CERN Document Server

    Alpat, B; Battiston, R; Bourquin, Maurice; Burger, W J; Extermann, Pierre; Chang, Y H; Hou, S R; Pauluzzi, M; Produit, N; Qiu, S; Rapin, D; Ribordy, R; Toker, O; Wu, S X

    2000-01-01

    First results for the AMS silicon tracker readout performance are presented. Small 20.0*20.0*0.300 mm/sup 3/ silicon microstrip detectors were installed in a 50 GeV electron beam at CERN. The detector readout consisted of prototypes of the tracker data reduction card equipped with a 12-bit ADC and the tracker frontend hybrid with VA_hdr readout chips. The system performance is assessed in terms of signal-to-noise, position resolution, and efficiency. (13 refs).

  10. Column-Parallel Single Slope ADC with Digital Correlated Multiple Sampling for Low Noise CMOS Image Sensors

    NARCIS (Netherlands)

    Chen, Y.; Theuwissen, A.J.P.; Chae, Y.

    2011-01-01

    This paper presents a low noise CMOS image sensor (CIS) using 10/12 bit configurable column-parallel single slope ADCs (SS-ADCs) and digital correlated multiple sampling (CMS). The sensor used is a conventional 4T active pixel with a pinned-photodiode as photon detector. The test sensor was

  11. Low cost photomultiplier high-voltage readout system

    International Nuclear Information System (INIS)

    Oxoby, G.J.; Kunz, P.F.

    1976-10-01

    The Large Aperture Solenoid Spectrometer (LASS) at Stanford Linear Accelerator Center (SLAC) requires monitoring over 300 voltages. This data is recorded on magnetic tapes along with the event data. It must also be displayed so that operators can easily monitor and adjust the voltages. A low-cost high-voltage readout system has been implemented to offer stand-alone digital readout capability as well as fast data transfer to a host computer. The system is flexible enough to permit use of a DVM or ADC and commercially available analogue multiplexers

  12. A mixed signal ECG processing platform with an adaptive sampling ADC for portable monitoring applications.

    Science.gov (United States)

    Kim, Hyejung; Van Hoof, Chris; Yazicioglu, Refet Firat

    2011-01-01

    This paper describes a mixed-signal ECG processing platform with an 12-bit ADC architecture that can adapt its sampling rate according to the input signals rate of change. This enables the sampling of ECG signals with significantly reduced data rate without loss of information. The presented adaptive sampling scheme reduces the ADC power consumption, enables the processing of ECG signals with lower power consumption, and reduces the power consumption of the radio while streaming the ECG signals. The test results show that running a CWT-based R peak detection algorithm using the adaptively sampled ECG signals consumes only 45.6 μW and it leads to 36% less overall system power consumption.

  13. Drift chamber and pulse height readout systems using analog multiplexing

    International Nuclear Information System (INIS)

    Cisneros, E.L; Kang, H.K.; Hall, J.N.; Larsen, R.S.

    1976-11-01

    Drift chamber and pulse-height readout systems are being developed for use in a new large scale detector at the SPEAR colliding beam facility. The systems are based upon 32 channels of sample-and-hold together with an analog multiplexer in a single-width CAMAC module. The modules within each crate are scanned by an autonomous controller containing a single ADC and memory plus arithmetic capability for offset, gain and linearity corrections. The drift chamber module has a facility for extracting hit wire information for use in trigger decision circuitry

  14. A Fast Multiple Sampling Method for Low-Noise CMOS Image Sensors With Column-Parallel 12-bit SAR ADCs

    Directory of Open Access Journals (Sweden)

    Min-Kyu Kim

    2015-12-01

    Full Text Available This paper presents a fast multiple sampling method for low-noise CMOS image sensor (CIS applications with column-parallel successive approximation register analog-to-digital converters (SAR ADCs. The 12-bit SAR ADC using the proposed multiple sampling method decreases the A/D conversion time by repeatedly converting a pixel output to 4-bit after the first 12-bit A/D conversion, reducing noise of the CIS by one over the square root of the number of samplings. The area of the 12-bit SAR ADC is reduced by using a 10-bit capacitor digital-to-analog converter (DAC with four scaled reference voltages. In addition, a simple up/down counter-based digital processing logic is proposed to perform complex calculations for multiple sampling and digital correlated double sampling. To verify the proposed multiple sampling method, a 256 × 128 pixel array CIS with 12-bit SAR ADCs was fabricated using 0.18 μm CMOS process. The measurement results shows that the proposed multiple sampling method reduces each A/D conversion time from 1.2 μs to 0.45 μs and random noise from 848.3 μV to 270.4 μV, achieving a dynamic range of 68.1 dB and an SNR of 39.2 dB.

  15. Performance evaluation of the analogue front-end and ADC prototypes for the Gotthard-II development

    Science.gov (United States)

    Zhang, J.; Andrä, M.; Barten, R.; Bergamaschi, A.; Brückner, M.; Dinapoli, R.; Fröjdh, E.; Greiffenberg, D.; Lopez-Cuenca, C.; Mezza, D.; Mozzanica, A.; Ramilli, M.; Redford, S.; Ruat, M.; Ruder, C.; Schmitt, B.; Shi, X.; Thattil, D.; Tinti, G.; Turcato, M.; Vetter, S.

    2017-12-01

    Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), energy dispersive experiments at 4.5 MHz frame rate, beam diagnostics, as well as veto signal generation for pixel detectors. Gotthard-II uses a silicon microstrip sensor with a pitch of 50 μm or 25 μm and with 1280 or 2560 channels wire-bonded to readout chips (ROCs). In the ROC, an adaptive gain switching pre-amplifier (PRE), a fully differential Correlated-Double-Sampling (CDS) stage, an Analog-to-Digital Converter (ADC) as well as a Static Random-Access Memory (SRAM) capable of storing all the 2700 images in an XFEL.EU bunch train will be implemented. Several prototypes with different designs of the analogue front-end (PRE and CDS) and ADC test structures have been fabricated in UMC-110 nm CMOS technology and their performance has been evaluated. In this paper, the performance of the analogue front-end and ADC will be summarized.

  16. New read-out electronics for ICARUS-T600 liquid Argon TPC. Description, simulation and tests of the new front-end and ADC system arXiv

    CERN Document Server

    Bagby, L.; Bellini, V.; Bonesini, M.; Braggiotti, A.; Castellani, L.; Centro, S.; Cervi, T.; Cocco, A.G.; Fabris, F.; Falcone, A.; Farnese, C.; Fava, A.; Fichera, F.; Franciotti, D.; Galet, G.; Gibin, D.; Guglielmi, A.; Guida, R.; Ketchum, W.; Marchini, S.; Menegolli, A.; Meng, G.; Menon, G.; Montanari, C.; Nessi, M.; Nicoletto, M.; Pedrotta, R.; Picchi, P.; Pietropaolo, F.; Rampazzo, G.; Rappoldi, A.; Raselli, G.L.; Rossella, M.; Rubbia, C.; Scaramelli, A.; Sergiampietri, F.; Spanu, M.; Torti, M.; Tortorici, F.; Varanini, F.; Ventura, S.; Vignoli, C.; Zani, A.; Zatti, P.G.

    The ICARUS T600, a liquid argon time projection chamber (LAr-TPC) detector mainly devoted to neutrino physics, underwent a major overhauling at CERN in 2016-2017, which included also a new design of the read-out electronics, in view of its operation in Fermilab on the Short Baseline Neutrino (SBN) beam from 2019. The new more compact electronics showed capability of handling more efficiently the signals also in the intermediate Induction 2 wire plane with a significant increase of signal to noise (S/N), allowing for charge measurement also in this view. The new front-end and the analog to digital conversion (ADC) system are presented together with the results of the tests on 50 liters liquid argon TPC performed at CERN with cosmic rays.

  17. Conversion of ADC pulse heights into MIP units (NUMASS test data, September 1991)

    International Nuclear Information System (INIS)

    Zhang, Q.P.

    1993-04-01

    ADC calibration is an important part of the data analysis in particle physics. Data analysis of ADC pulse heights is based on a physical unit which is called MIP (most probable energy loss of Minimum Ionization Particles). This paper describes the ADC calibration work for the September 1991 NUMASS test data, which were produced at CERN at the SPS facility. The Vavilov function is used to fit the energy loss distributions of minimum ionizing particles traversing the time of flight scintillators embedded in the uranium scintillator calorimeter. It is assumed that the energy loss distribution is the same for identical scintillators and the value at the peak of these distributions is used, i.e., the most probable energy loss, as a physical unit to derive the gains of the individual readout channels

  18. Development of an event builder for the new SADC-readout of the crystal barrel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Schultes, Jan; Muellers, Johannes [Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Collaboration: CBELSA/TAPS-Collaboration

    2016-07-01

    The CBELSA/TAPS experiment at the electron accelerator ELSA in Bonn investigates the photoproduction of mesons off nucleons. Presently the readout of the CsI(Tl)-crystals of the Crystal Barrel calorimeter is being upgraded from a PIN-diode readout to an APD readout to create a fast signal for first-level-triggering. Furthermore, an entirely new setup consisting of Sampling-ADCs (SADC) with FPGA-based readout is being prepared to increase the possible data rate achievable. The SADC is capable of sampling pulses from the detector with 80 MHz, extracting features by FPGA-logic and transferring this data via UDP. To improve package-handling, a server-client structure will be provided. It is foreseen to receive packages from each of the 48 SADC units (32 channels each), detect and handle possible package losses, distribute the received information further via TCP and control the SADC-behaviour. In addition and to assist the FPGA firmware development, a tool to monitor outgoing pulses and to extract important features, such as the deposited energy, timing information and pile-up detection to cross-check the information given by the FPGA is being developed.

  19. A SAR-ADC using unit bridge capacitor and with calibration for the front-end electronics of PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wei [School of Computer Science and Engineering, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Wei, Tingcun, E-mail: weitc@nwpu.edu.cn [School of Computer Science and Engineering, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Li, Bo; Yang, Lifeng; Xue, Feifei [School of Computer Science and Engineering, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China); Hu, Yongcai [Institut Pluridisciplinaire Hubert CURIEN, Strasbourg (France)

    2016-05-11

    This paper presents a 12-bit 1 MS/s successive approximation register-analog to digital converter (SAR-ADC) for the 32-channel front-end electronics of CZT-based PET imaging system. To reduce the capacitance mismatch, instead of the fractional capacitor, the unit capacitor is used as the bridge capacitor in the split-capacitor digital to analog converter (DAC) circuit. In addition, in order to eliminate the periodical DNL errors of −1 LSB which often exists in the SAR-ADC using the charge-redistributed DAC, a calibration algorithm is proposed and verified by the experiments. The proposed 12-bit 1 MS/s SAR-ADC is designed and implemented using a 0.35 μm CMOS technology, it occupies only an active area of 986×956 μm{sup 2}. The measurement results show that, at the power supply of 3.3/5.0 V and the sampling rate of 1 MS/s, the ADC with calibration has a signal-to-noise-and-distortion ratio (SINAD) of 67.98 dB, the power dissipation of 5 mW, and a figure of merit (FOM) of 2.44 pJ/conv.-step. This ADC is with the features of high accuracy, low power and small layout area, it is especially suitable to the one-chip integration of the front-end readout electronics.

  20. A 16 bit camac ADC with memory

    International Nuclear Information System (INIS)

    Wikne, J.C.

    1986-01-01

    A 16 bit camac-programmable analog-to-digital converter (ADC) with incorporated memory and sampling clock is described. This single-width camac module is especially suited for autonomous, multi-sample data acquisition with high precision. The ADC itself is a hybrid, the ADC76 from Burr-Brown, featuring a programmable input range and direct parallel output in two's complement form. The input programming is done by means of dual-in-line switches, giving input spans from 1.25 V to 20 V, unipolar or bipolar. The outline of the programming of the ADC input and the calibration of the unit is given

  1. A 14-bit 50 MS/s sample-and-hold circuit for pipelined ADC

    International Nuclear Information System (INIS)

    Yue Sen; Zhao Yiqiang; Pang Ruilong; Sheng Yun

    2014-01-01

    A high performance sample-and-hold (S/H) circuit used in a pipelined analog-to-digital converter (ADC) is presented. Capacitor flip-around architecture is used in this S/H circuit with a novel gain-boosted differential folded cascode operational transconductance amplifier. A double-bootstrapped switch is designed to improve the performance of the circuit. The circuit is implemented using a 0.18 μm 1P6M CMOS process. Measurement results show that the effective number of bits is 14.03 bits, the spurious free dynamic range is 94.62 dB, the signal to noise and distortion ratio is 86.28 dB, and the total harmonic distortion is −91:84 dB for a 5 MHz input signal with 50 MS/s sampling rate. A pipeline ADC with the designed S/H circuit has been implemented. (semiconductor integrated circuits)

  2. Microcontroller based four-channel current readout unit for beam slit monitor

    International Nuclear Information System (INIS)

    Holikatti, A.C.; Puntambekar, T.A.; Pithawa, C.K.

    2009-01-01

    This paper describes the design and development of a microcontroller based four-channel current readout unit for Beam Slit Monitor (BSM) installed in Transport Line-1 of Indus Accelerator Complex. BSM is a diagnostic device consisting of two horizontal and two vertical blades, which can be moved independently in to the beam pipe to cut the beam transversely. The readout unit employs switched integrators with reset, hold and select switches and timing and control unit. It integrates the current output of the four blades of BSM and produces an output corresponding to the beam charge intercepted by the blade. The integrator outputs are then multiplexed and digitized using 12-bit ADC. Acquired digital data from ADC is stored into on-chip RAM of the microcontroller. The readout sequence is synchronized with the Microtron beam-timing signal. The timing of integration, hold and reset cycles is controlled by the microcontroller. The unit is connected on a serial link to the host computer in main control room. This unit has been integrated with the BSM system and is being used to obtain the electron beam profile. (author)

  3. A portable battery powered microfluidic impedance cytometer with smartphone readout: towards personal health monitoring.

    Science.gov (United States)

    Talukder, Niloy; Furniturewalla, Abbas; Le, Tuan; Chan, Matthew; Hirday, Shreyas; Cao, Xinnan; Xie, Pengfei; Lin, Zhongtian; Gholizadeh, Azam; Orbine, Steve; Javanmard, Mehdi

    2017-06-01

    We present a portable system for personalized blood cell counting consisting of a microfluidic impedance cytometer and portable analog readout electronics, feeding into an analog-to-digital converter (ADC), and being transmitted via Bluetooth to a user-accessible mobile application. We fabricated a microfluidic impedance cytometer with a novel portable analog readout. The novel design of the analog readout, which consists of a lock-in-amplifier followed by a high-pass filter stage for subtraction of drift and DC offset, and a post-subtraction high gain stage, enables detection of particles and cells as small as 1 μm in diameter, despite using a low-end 8-bit ADC. The lock-in-amplifier and the ADC were set up to receive and transmit data from a Bluetooth module. In order to initiate the system, as well as to transmit all of the data, a user friendly mobile application was developed, and a proof-of-concept trial was run on a blood sample. Applications such as personalized health monitoring require robust device operation and resilience to clogging. It is desirable to avoid using channels comparable in size to the particles being detected thus requiring high levels of sensitivity. Despite using low-end off-the-shelf hardware, our sensing platform was capable of detecting changes in impedance as small as 0.032%, allowing detection of 3 μm diameter particles in a 300 μm wide channel. The sensitivity of our system is comparable to that of a high-end bench-top impedance spectrometer when tested using the same sensors. The novel analog design allowed for an instrument with a footprint of less than 80 cm 2 . The aim of this work is to demonstrate the potential of using microfluidic impedance spectroscopy for low cost health monitoring. We demonstrated the utility of the platform technology towards cell counting, however, our platform is broadly applicable to assaying wide panels of biomarkers including proteins, nucleic acids, and various cell types.

  4. A fast readout algorithm for Cluster Counting/Timing drift chambers on a FPGA board

    Energy Technology Data Exchange (ETDEWEB)

    Cappelli, L. [Università di Cassino e del Lazio Meridionale (Italy); Creti, P.; Grancagnolo, F. [Istituto Nazionale di Fisica Nucleare, Lecce (Italy); Pepino, A., E-mail: Aurora.Pepino@le.infn.it [Istituto Nazionale di Fisica Nucleare, Lecce (Italy); Tassielli, G. [Istituto Nazionale di Fisica Nucleare, Lecce (Italy); Fermilab, Batavia, IL (United States); Università Marconi, Roma (Italy)

    2013-08-01

    A fast readout algorithm for Cluster Counting and Timing purposes has been implemented and tested on a Virtex 6 core FPGA board. The algorithm analyses and stores data coming from a Helium based drift tube instrumented by 1 GSPS fADC and represents the outcome of balancing between cluster identification efficiency and high speed performance. The algorithm can be implemented in electronics boards serving multiple fADC channels as an online preprocessing stage for drift chamber signals.

  5. A Full Slice Test Version of a Tentative Upgraded Readout System for TileCal

    CERN Document Server

    Muschter, S; The ATLAS collaboration; Bohm, C; Eriksson, D; Kavianipour, H; Oreglia, M; Tang, F

    2011-01-01

    The upgrade plans on the ATLAS hadronic calorimeter (TileCal) include the full readout of all data to the counting room. In order to study functional requirements of the future upgraded TileCal readout system we have assembled a minimal TDAQ slice. The aim is to implement a tentative readout chain for TileCal, starting with a newly developed 3-in-1 FE-board from University of Chicago and ending with the storage of triggered data on a PC. Later we will use PMT pulses, amplified and shaped by the 3-in-1 board, as a data source. However, for simplicity we start by using well defined calibration pulses also generated by the 3-in-1 board. The pulses are sampled by a 12 bit ADC, which is connected to an ML605 evaluation board from XILINX. These boards emulate the new on-detector electronics. The ML605 communicates via two 5Gb/s optical links with a Virtex-6 FPGA development board from HighTech Global which emulates the off-detector electronics. The off-detector board is situated in a PC and uses PCIe for readout an...

  6. SVX3: A deadtimeless readout chip for silicon strip detectors

    International Nuclear Information System (INIS)

    Zimmerman, T.; Huffman, T.; Srage, J.; Stroehmer, R.; Yarema, R.; Garcia-Sciveras, M.; Luo, L.; Milgrome, O.

    1997-12-01

    A new silicon strip readout chip called the SVX3 has been designed for the 720,000 channel CDF silicon upgrade at Fermilab. SVX3 incorporates an integrator, analog delay pipeline, ADC, and data sparsification for each of 128 identical channels. Many of the operating parameters are programmable via a serial bit stream, which allows the chip to be used under a variety of conditions. Distinct features of SVX3 include use of a backside substrate contact for optimal ground referencing, and the capability of simultaneous signal acquisition and digital readout allowing deadtimeless operation in the Fermilab Tevatron

  7. LSST camera readout chip ASPIC: test tools

    Science.gov (United States)

    Antilogus, P.; Bailly, Ph; Jeglot, J.; Juramy, C.; Lebbolo, H.; Martin, D.; Moniez, M.; Tocut, V.; Wicek, F.

    2012-02-01

    The LSST camera will have more than 3000 video-processing channels. The readout of this large focal plane requires a very compact readout chain. The correlated ''Double Sampling technique'', which is generally used for the signal readout of CCDs, is also adopted for this application and implemented with the so called ''Dual Slope integrator'' method. We have designed and implemented an ASIC for LSST: the Analog Signal Processing asIC (ASPIC). The goal is to amplify the signal close to the output, in order to maximize signal to noise ratio, and to send differential outputs to the digitization. Others requirements are that each chip should process the output of half a CCD, that is 8 channels and should operate at 173 K. A specific Back End board has been designed especially for lab test purposes. It manages the clock signals, digitizes the analog differentials outputs of ASPIC and stores data into a memory. It contains 8 ADCs (18 bits), 512 kwords memory and an USB interface. An FPGA manages all signals from/to all components on board and generates the timing sequence for ASPIC. Its firmware is written in Verilog and VHDL languages. Internals registers permit to define various tests parameters of the ASPIC. A Labview GUI allows to load or update these registers and to check a proper operation. Several series of tests, including linearity, noise and crosstalk, have been performed over the past year to characterize the ASPIC at room and cold temperature. At present, the ASPIC, Back-End board and CCD detectors are being integrated to perform a characterization of the whole readout chain.

  8. LSST camera readout chip ASPIC: test tools

    International Nuclear Information System (INIS)

    Antilogus, P; Bailly, Ph; Juramy, C; Lebbolo, H; Martin, D; Jeglot, J; Moniez, M; Tocut, V; Wicek, F

    2012-01-01

    The LSST camera will have more than 3000 video-processing channels. The readout of this large focal plane requires a very compact readout chain. The correlated ''Double Sampling technique'', which is generally used for the signal readout of CCDs, is also adopted for this application and implemented with the so called ''Dual Slope integrator'' method. We have designed and implemented an ASIC for LSST: the Analog Signal Processing asIC (ASPIC). The goal is to amplify the signal close to the output, in order to maximize signal to noise ratio, and to send differential outputs to the digitization. Others requirements are that each chip should process the output of half a CCD, that is 8 channels and should operate at 173 K. A specific Back End board has been designed especially for lab test purposes. It manages the clock signals, digitizes the analog differentials outputs of ASPIC and stores data into a memory. It contains 8 ADCs (18 bits), 512 kwords memory and an USB interface. An FPGA manages all signals from/to all components on board and generates the timing sequence for ASPIC. Its firmware is written in Verilog and VHDL languages. Internals registers permit to define various tests parameters of the ASPIC. A Labview GUI allows to load or update these registers and to check a proper operation. Several series of tests, including linearity, noise and crosstalk, have been performed over the past year to characterize the ASPIC at room and cold temperature. At present, the ASPIC, Back-End board and CCD detectors are being integrated to perform a characterization of the whole readout chain.

  9. The performance of a high speed pipelined photomultiplier readout system in the Fermilab KTe V experiment

    International Nuclear Information System (INIS)

    Whitmore, J.

    1997-08-01

    The KTeV fixed target experiment at Fermilab is using an innovative scheme for reading out its 3100 channel CsI electromagnetic calorimeter. This pipelined readout system digitizes photomultiplier tube (PMT) signals over a 16-bit dynamic range with 8-bits of resolution at 53 MHz. The crucial element of the system is a custom Bi-CMOS integrated circuit which, in conjunction with an 8-bit Flash ADC, integrates and digitizes the PMT signal charge over each 18.9 nsec clock cycle (53 MHz) in a deadtimeless fashion.The digitizer circuit is local to the PMT base, and has an in-situ charge integration noise figure of 3 fC/sample. In this article, the readout system will be described and its performance including noise, cross-talk, linearity, stability, and reliability will be discussed

  10. The Usefulness of Readout-Segmented Echo-Planar Imaging (RESOLVE) for Bio-phantom Imaging Using 3-Tesla Clinical MRI.

    Science.gov (United States)

    Yoshimura, Yuuki; Kuroda, Masahiro; Sugiantoc, Irfan; Bamgbosec, Babatunde O; Miyahara, Kanae; Ohmura, Yuichi; Kurozumi, Akira; Matsushita, Toshi; Ohno, Seiichiro; Kanazawa, Susumu; Asaumi, Junichi

    2018-02-01

    Readout-segmented echo-planar imaging (RESOLVE) is a multi-shot echo-planar imaging (EPI) modality with k-space segmented in the readout direction. We investigated whether RESOLVE decreases the distortion and artifact in the phase direction and increases the signal-to-noise ratio (SNR) in phantoms image taken with 3-tesla (3T) MRI versus conventional EPI. We used a physiological saline phantom and subtraction mapping and observed that RESOLVE's SNR was higher than EPI's. Using RESOLVE, the combination of a special-purpose coil and a large-loop coil had a higher SNR compared to using only a head/neck coil. RESOLVE's image distortioas less than EPI's. We used a 120 mM polyethylene glycol phantom to examine the phase direction artifact.vThe range where the artifact appeared in the apparent diffusion coefficient (ADC) image was shorter with RESOLVE compared to EPI. We used RESOLVE to take images of a Jurkat cell bio-phantom: the cell-region ADC was 856×10-6mm2/sec and the surrounding physiological saline-region ADC was 2,951×10-6mm2/sec. The combination of RESOLVE and the 3T clinical MRI device reduced image distortion and improved SNR and the identification of accurate ADC values due to the phase direction artifact reduction. This combination is useful for obtaining accurate ADC values of bio-phantoms.

  11. Requirements on read-out electronics for future keV-scale sterile neutrino search with KATRIN

    Energy Technology Data Exchange (ETDEWEB)

    Dolde, Kai [Karlsruhe Institute of Technology (KIT), Karlsruhe (Germany)

    2016-07-01

    Recent publications show the great potential of the KATRIN (KArlsruhe TRItium Neutrino) experiment in the search for sterile neutrinos in the mass range of a few keV down to active-to-sterile mixing angles at least one order of magnitude smaller than current laboratory limits of sin{sup 2}θ < 10{sup -3}. In order to be sensitive to the tiny kink-like signature of sterile neutrinos in tritium beta decay, KATRIN requires a novel sophisticated detector and read-out system. Several silicon prototype detectors are under construction at the moment to explore the most suitable detector design for this purpose. The selection of appropriate read-out electronics is strongly triggered by the requirements of allowing only very small systematic uncertainties due to ADC Non-Linearities to reach the expected sensitivity. This talk investigates the impact of ADC Non-Linearities on the tritium beta decay spectrum, depending on the digitization method of analogue signals of a multi-pixel silicon detector, peak sensing or waveform digitization. The simulations show a higher achievable sensitivity using waveform digitizers and moreover strongly favor additional variable post-acceleration of the electrons to smear out the periodic structure of the ADC Non-Linearities.

  12. Light-to-light readout system of the CMS electromagnetic calorimeter

    CERN Document Server

    Denes, P; Lustermann, W; Mathez, H; Pangaud, P; Walder, J P

    2001-01-01

    For the CMS experiment at the Large Hadron Collider at CERN, an 8OOOO-crysral electromagnetic calorimeter will measure electron and photon energies with high precision over a dynamic range of roughly 16 bits. The readout electronics will be located directly behind the crystals, and must survive a total dose of up to 2x10 Gy along with 5x10**1**3 n/cm**2. A readout chain consisting of a custom wide-range acquisition circuit, commercial ADC and custom optical link for each crystal is presently under construction. An overview of the design is presented, with emphasis on the large-scale fiber communication system. 11 Refs.

  13. LHCb - SALT, a dedicated readout chip for strip detectors in the LHCb Upgrade experiment

    CERN Multimedia

    Swientek, Krzysztof Piotr

    2015-01-01

    Silicon strip detectors in the upgraded Tracker of LHCb experiment will require a new readout 128-channel ASIC called SALT. It will extract and digitise analogue signals from the sensor, perform digital processing and transmit serial output data. SALT is designed in CMOS 130 nm process and uses a novel architecture comprising of analogue front-end and ultra-low power ($<$0.5 mW) fast (40 MSps) sampling 6-bit ADC in each channel. A prototype of first 8-channel version of SALT chip, comprising all important functionalities, was submitted. Its design and possibly first tests results will be presented.

  14. Design and characterization of the readout ASIC for the BESIII CGEM detector

    CERN Document Server

    Cossio, Fabio; Bugalho, Ricardo; Chai, Junying; Cheng, Weishuai; Da Rocha Rolo, Manuel Dionisio; Di Francesco, Agostino; Greco, Michela; Leng, Chongyang; Li, Huaishen; Maggiora, Marco; Marcello, Simonetta; Mignone, Marco; Rivetti, Angelo; Varela, Joao; Wheadon, Richard

    2018-01-01

    TIGER (Turin Integrated Gem Electronics for Readout) is a mixed-mode ASIC for the readout of signals from CGEM (Cylindrical Gas Electron Multiplier) detector in the upgraded inner tracker of the BESIII experiment, carried out at BEPCII in Beijing. The ASIC includes 64 channels, each of which features a dual-branch architecture optimized for timing and energy measurement. The input signal time-of-arrival and charge measurement is provided by low-power TDCs, based on analogue interpolation techniques, and Wilkinson ADCs, with a fully-digital output. The silicon results of TIGER first prototype are presented showing its full functionality.

  15. [Evaluation of Image Quality of Readout Segmented EPI with Readout Partial Fourier Technique].

    Science.gov (United States)

    Yoshimura, Yuuki; Suzuki, Daisuke; Miyahara, Kanae

    Readout segmented EPI (readout segmentation of long variable echo-trains: RESOLVE) segmented k-space in the readout direction. By using the partial Fourier method in the readout direction, the imaging time was shortened. However, the influence on image quality due to insufficient data sampling is concerned. The setting of the partial Fourier method in the readout direction in each segment was changed. Then, we examined signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and distortion ratio for changes in image quality due to differences in data sampling. As the number of sampling segments decreased, SNR and CNR showed a low value. In addition, the distortion ratio did not change. The image quality of minimum sampling segments is greatly different from full data sampling, and caution is required when using it.

  16. Photoproduction γp→pπ0π0. Results and development of a fast FADC-readout for double polarization experiments

    International Nuclear Information System (INIS)

    Szczepanek, T.

    2006-01-01

    This thesis describes the development and testing of a very fast intersection card for the driving and readout of a struck DL300 flash-ADC system. In order to permit an as fast as possible processing and storage of the data, an intersection on the base of a field-programmable integrated circuit was developed, which is placed on PCI/PMC plug-card together with fast memory and can transmit the data to the readout processor via a direct storage transmission from the memory of the control card to the applied CPU. The readout of the DL300 system pursues thereby autonomeously on the integrated circuit. First test measurements in the laboratory show that the flash ADC readout is functionable and dtat rates of 1 kHz or more can be reached. Furthermore the establishment of a graphical control software for the data-acquisition system in combination with a system for the processing, storage, and display of status informations of the data acquisition as well as a hardware synchronization module and an interrupt module on the base of a serial RS-232 intersection for the Linux kernel are presented, which were also developed in the framework of this thesis

  17. Novel concept of TDI readout circuit for LWIR detector

    Science.gov (United States)

    Kim, Byunghyuck; Yoon, Nanyoung; Lee, Hee Chul; Kim, Choong-Ki

    2000-07-01

    Noise property is the prime consideration in readout circuit design. The output noise caused by the photon noise, which dominates total noise in BLIP detectors, is limited by the integration time that an element looks at a specific point in the scene. Large integration time leads to a low noise performance. Time-delay integration (TDI) is used to effectively increase the integration time and reduce the photon noise. However, it increases the number of dead pixels and requires large integration capacitors and low noise output stage of the readout circuit. In this paper, to solve these problems, we propose a new concept of readout circuit, which performs background suppression, cell-to-cell background current non-uniformity compensation, and dead pixel correction using memory, ADC, DAC, and current copier cell. In simulation results, comparing with the conventional TDI readout circuit, the integration capacitor size can be reduced to 1/5 and trans-impedance gain can be increased by five times. Therefore, the new TDI readout circuit does not require large area and low noise output stage. And the error of skimming current is less than 2%, and the fixed pattern noise induced by cell-to-cell background current variation is reduced to less than 1%.

  18. Recent Developments on the Silicon Drift Detector readout scheme for the ALICE Inner Tracking System

    CERN Document Server

    Mazza, G; Bonazzola, G C; Bonvicini, V; Cavagnino, D; Cerello, P G; De Remigis, P; Falchieri, D; Gabrielli, A; Gandolfi, E; Giubellino, P; Hernández, R; Masetti, M; Montaño-Zetina, L M; Nouais, D; Rashevsky, A; Rivetti, A; Tosello, F

    1999-01-01

    Proposal of abstract for LEB99, Snowmass, Colorado, 20-24 September 1999Recent developments of the Silicon Drift Detector (SDD) readout system for the ALICE Experiment are presented. The foreseen readout system is based on 2 main units. The first unit consists of a low noise preamplifier, an analog memory which continuously samples the amplifier output, an A/D converter and a digital memory. When the trigger signal validates the analog data, the ADCs convert the samples into a digital form and store them into the digital memory. The second unit performs the zero suppression/data compression operations. In this paper the status of the design is presented, together with the test results of the A/D converter, the multi-event buffer and the compression unit prototype.Summary:In the Inner Tracker System (ITS) of the ALICE experiment the third and the fourth layer of the detectors are SDDs. These detectors provide the measurement of both the energy deposition and the bi-dimensional position of the track. In terms o...

  19. A 9-Bit 50 MSPS Quadrature Parallel Pipeline ADC for Communication Receiver Application

    Science.gov (United States)

    Roy, Sounak; Banerjee, Swapna

    2018-03-01

    This paper presents the design and implementation of a pipeline Analog-to-Digital Converter (ADC) for superheterodyne receiver application. Several enhancement techniques have been applied in implementing the ADC, in order to relax the target specifications of its building blocks. The concepts of time interleaving and double sampling have been used simultaneously to enhance the sampling speed and to reduce the number of amplifiers used in the ADC. Removal of a front end sample-and-hold amplifier is possible by employing dynamic comparators with switched capacitor based comparison of input signal and reference voltage. Each module of the ADC comprises two 2.5-bit stages followed by two 1.5-bit stages and a 3-bit flash stage. Four such pipeline ADC modules are time interleaved using two pairs of non-overlapping clock signals. These two pairs of clock signals are in phase quadrature with each other. Hence the term quadrature parallel pipeline ADC has been used. These configurations ensure that the entire ADC contains only eight operational-trans-conductance amplifiers. The ADC is implemented in a 0.18-μm CMOS process and supply voltage of 1.8 V. The proto-type is tested at sampling frequencies of 50 and 75 MSPS producing an Effective Number of Bits (ENOB) of 6.86- and 6.11-bits respectively. At peak sampling speed, the core ADC consumes only 65 mW of power.

  20. Test vehicles for CMS HGCAL readout ASIC

    CERN Document Server

    Thienpont, Damien

    2017-01-01

    This paper presents first measurement results of two test vehicles ASIC embedding some building blocks for the future CMS High Granularity CALorimeter (HGCAL) read-out ASIC. They were fabricated in CMOS 130 nm, in order to first design the Analog and Mixed-Signal blocks before going to a complete and complex chip. Such a circuit needs to achieve low noise high dynamic range charge measurement and 20 ps resolution timing capability. The results show good analog performance but with higher noise levels compared to simulations. We present the results of the preamplifiers, shapers and ADCs.

  1. A Differential Electrochemical Readout ASIC With Heterogeneous Integration of Bio-Nano Sensors for Amperometric Sensing.

    Science.gov (United States)

    Ghoreishizadeh, Sara S; Taurino, Irene; De Micheli, Giovanni; Carrara, Sandro; Georgiou, Pantelis

    2017-10-01

    A monolithic biosensing platform is presented for miniaturized amperometric electrochemical sensing in CMOS. The system consists of a fully integrated current readout circuit for differential current measurement as well as on-die sensors developed by growing platinum nanostructures (Pt-nanoS) on top of electrodes implemented with the top metal layer. The circuit is based on the switch-capacitor technique and includes pseudodifferential integrators for concurrent sampling of the differential sensor currents. The circuit further includes a differential to single converter and a programmable gain amplifier prior to an ADC. The system is fabricated in [Formula: see text] technology and measures current within [Formula: see text] with minimum input-referred noise of [Formula: see text] and consumes [Formula: see text] from a [Formula: see text] supply. Differential sensing for nanostructured sensors is proposed to build highly sensitive and offset-free sensors for metabolite detection. This is successfully tested for bio-nano-sensors for the measurement of glucose in submilli molar concentrations with the proposed readout IC. The on-die electrodes are nanostructured and cyclic voltammetry run successfully through the readout IC to demonstrate detection of [Formula: see text].

  2. A compact readout system for multi-pixel hybrid photodiodes

    International Nuclear Information System (INIS)

    Datema, C.P.; Meng, L.J.; Ramsden, D.

    1999-01-01

    Although the first Multi-pixel Hybrid Photodiode (M-HPD) was developed in the early 1990s by Delft Electronic Products, the main obstacle to its application has been the lack of availability of a compact read-out system. A fast, parallel readout system has been constructed for use with the earlier 25-pixel tube with High-energy Physics applications in mind. The excellent properties of the recently developed multi-pixel hybrid photodiodes (M-HPD) will be easier to exploit following the development of the new hybrid read-out circuits described in this paper. This system will enable all of the required read-out functions to be accommodate on a single board into which the M-HPD is plugged. The design and performance of a versatile system is described in which a trigger-signal, derived from the common-side of the silicon anode in the M-HPD, is used to trigger the readout of the 60-anode pixels in the M-HPD. The multi-channel amplifier section is based on the use of a new, commercial VLSI chip, whilst the read-out sequencer uses a chip of its own design. The common anode signal is processed by a fast amplifier and discriminator to provide a trigger signal when a single event is detected. In the prototype version, the serial analogue output data-stream is processed using a PC-mounted, high speed ADC. Results obtained using the new read-out system in a compact gamma-camera and with a small muon tracking-chamber demonstrate the low-noise performance of the system. The application of this read-out system in other position-sensitive or multi-anode photomultiplier tube applications are also described

  3. The Front-End Readout as an Encoder IC for Magneto-Resistive Linear Scale Sensors

    Directory of Open Access Journals (Sweden)

    Trong-Hieu Tran

    2016-09-01

    Full Text Available This study proposes a front-end readout circuit as an encoder chip for magneto-resistance (MR linear scales. A typical MR sensor consists of two major parts: one is its base structure, also called the magnetic scale, which is embedded with multiple grid MR electrodes, while another is an “MR reader” stage with magnets inside and moving on the rails of the base. As the stage is in motion, the magnetic interaction between the moving stage and the base causes the variation of the magneto-resistances of the grid electrodes. In this study, a front-end readout IC chip is successfully designed and realized to acquire temporally-varying resistances in electrical signals as the stage is in motions. The acquired signals are in fact sinusoids and co-sinusoids, which are further deciphered by the front-end readout circuit via newly-designed programmable gain amplifiers (PGAs and analog-to-digital converters (ADCs. The PGA is particularly designed to amplify the signals up to full dynamic ranges and up to 1 MHz. A 12-bit successive approximation register (SAR ADC for analog-to-digital conversion is designed with linearity performance of ±1 in the least significant bit (LSB over the input range of 0.5–2.5 V from peak to peak. The chip was fabricated by the Taiwan Semiconductor Manufacturing Company (TSMC 0.35-micron complementary metal oxide semiconductor (CMOS technology for verification with a chip size of 6.61 mm2, while the power consumption is 56 mW from a 5-V power supply. The measured integral non-linearity (INL is −0.79–0.95 LSB while the differential non-linearity (DNL is −0.68–0.72 LSB. The effective number of bits (ENOB of the designed ADC is validated as 10.86 for converting the input analog signal to digital counterparts. Experimental validation was conducted. A digital decoder is orchestrated to decipher the harmonic outputs from the ADC via interpolation to the position of the moving stage. It was found that the displacement

  4. Two-step single slope/SAR ADC with error correction for CMOS image sensor.

    Science.gov (United States)

    Tang, Fang; Bermak, Amine; Amira, Abbes; Amor Benammar, Mohieddine; He, Debiao; Zhao, Xiaojin

    2014-01-01

    Conventional two-step ADC for CMOS image sensor requires full resolution noise performance in the first stage single slope ADC, leading to high power consumption and large chip area. This paper presents an 11-bit two-step single slope/successive approximation register (SAR) ADC scheme for CMOS image sensor applications. The first stage single slope ADC generates a 3-bit data and 1 redundant bit. The redundant bit is combined with the following 8-bit SAR ADC output code using a proposed error correction algorithm. Instead of requiring full resolution noise performance, the first stage single slope circuit of the proposed ADC can tolerate up to 3.125% quantization noise. With the proposed error correction mechanism, the power consumption and chip area of the single slope ADC are significantly reduced. The prototype ADC is fabricated using 0.18 μ m CMOS technology. The chip area of the proposed ADC is 7 μ m × 500 μ m. The measurement results show that the energy efficiency figure-of-merit (FOM) of the proposed ADC core is only 125 pJ/sample under 1.4 V power supply and the chip area efficiency is 84 k  μ m(2) · cycles/sample.

  5. Two-Step Single Slope/SAR ADC with Error Correction for CMOS Image Sensor

    Directory of Open Access Journals (Sweden)

    Fang Tang

    2014-01-01

    Full Text Available Conventional two-step ADC for CMOS image sensor requires full resolution noise performance in the first stage single slope ADC, leading to high power consumption and large chip area. This paper presents an 11-bit two-step single slope/successive approximation register (SAR ADC scheme for CMOS image sensor applications. The first stage single slope ADC generates a 3-bit data and 1 redundant bit. The redundant bit is combined with the following 8-bit SAR ADC output code using a proposed error correction algorithm. Instead of requiring full resolution noise performance, the first stage single slope circuit of the proposed ADC can tolerate up to 3.125% quantization noise. With the proposed error correction mechanism, the power consumption and chip area of the single slope ADC are significantly reduced. The prototype ADC is fabricated using 0.18 μm CMOS technology. The chip area of the proposed ADC is 7 μm × 500 μm. The measurement results show that the energy efficiency figure-of-merit (FOM of the proposed ADC core is only 125 pJ/sample under 1.4 V power supply and the chip area efficiency is 84 k μm2·cycles/sample.

  6. Photoluminescence detection of alpha particle using DAM-ADC nuclear detector

    Energy Technology Data Exchange (ETDEWEB)

    Abdalla, Ayman M., E-mail: aymanabdalla62@hotmail.com [Department of Physics, College of Science and Arts, Najran University, P.O. Box 1988, Najran 11001 (Saudi Arabia); Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, P.O. Box: 1988, Najran 11001 (Saudi Arabia); Harraz, Farid A., E-mail: fharraz68@yahoo.com [Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, P.O. Box: 1988, Najran 11001 (Saudi Arabia); Nanostructured Materials and Nanotechnology Division, Central Metallurgical Research and Development Institute (CMRDI), P.O. Box: 87 Helwan, Cairo 11421 (Egypt); Ali, Atif M. [Department of Physics, Faculty of Science, King Khalid University, Abha (Saudi Arabia); Al-Sayari, S.A. [Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, P.O. Box: 1988, Najran 11001 (Saudi Arabia); College of Science and Arts-Sharoura, Najran University (Saudi Arabia); Al-Hajry, A. [Department of Physics, College of Science and Arts, Najran University, P.O. Box 1988, Najran 11001 (Saudi Arabia); Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, P.O. Box: 1988, Najran 11001 (Saudi Arabia)

    2016-09-11

    The photoluminescence (PL) and UV–vis spectral analysis of DAM-ADC (diallyl maleate: DAM, polyallyl diglycol carbonate: ADC) nuclear detector are demonstrated for the first time. The DAM-ADC surfaces were exposed to thin {sup 241}Am disk source that emits alpha particles with activity 333 kBq. It is found that the track density of the irradiated samples remarkably influences the PL characteristics of the DAM-ADC detector. The spectral peak heights and the integrated intensities under the peaks exhibit linear correlations with correlation coefficient R{sup 2}=0.9636 and 0.9806, respectively for different alpha particle fluences ranging from 8.16–40.82×10{sup 7} particles/cm{sup 2}. Additionally, a correlation coefficient R{sup 2}=0.9734 was achieved for the UV–vis spectral analysis. The linear fitting functions, along with the corresponding fitting parameters were evaluated in each case. Both the PL and the UV–vis data of the irradiated DAM-ADC samples showed considerable spectral differences, and hence they would be used to offer sensitive approaches for alpha particle detection.

  7. ADC Catalog Services: an Update

    Science.gov (United States)

    Gass, J. E.; Roman, N. G.; Schneider, G. L.; Blackwell, J. H.; Kuin, N. P. M.; Larkin, M. C.; Lyu, C.-C. J.; Cheung, C. Y.

    1996-12-01

    The Astronomical Data Center (ADC) at the NASA Goddard Space Flight Center is a major archive and distribution center for computer-readable versions of astronomical catalogs and journal data tables. The ADC's archives contain more than 1600 catalogs and tables of astrometry, photometry, spectroscopy, radio, high energy, and other miscellaneous data for stellar and non-stellar objects. These data files are documented in a standardized manner, developed in cooperation with the Centre de Donnees astronomiques de Strasbourg (CDS). The ADC's data collection is available via anonymous FTP from node adc.gsfc.nasa.gov in the /pub/adc/archives directory. The holdings can also be accessed from the ADC's WWW site, http://adc.gsfc.nasa.gov/. This site permits users to search the text of the documentation files to locate catalogs and tables of interest or to browse the archives. Hypertext author and keyword indices, and other browsing tools have recently been developed as additional aids to navigating the ADC's large collection of data sets. The ADC is currently developing services to allow researchers to easily locate data fields of interest within files in its archives. The ADC has also prepared three volumes of CD-ROMs that contain several hundred of the largest and most requested catalogs in both ASCII and FITS table formats.

  8. High performance 14-bit pipelined redundant signed digit ADC

    International Nuclear Information System (INIS)

    Narula, Swina; Pandey, Sujata

    2016-01-01

    A novel architecture of a pipelined redundant-signed-digit analog to digital converter (RSD-ADC) is presented featuring a high signal to noise ratio (SNR), spurious free dynamic range (SFDR) and signal to noise plus distortion (SNDR) with efficient background correction logic. The proposed ADC architecture shows high accuracy with a high speed circuit and efficient utilization of the hardware. This paper demonstrates the functionality of the digital correction logic of 14-bit pipelined ADC at each 1.5 bit/stage. This prototype of ADC architecture accounts for capacitor mismatch, comparator offset and finite Op-Amp gain error in the MDAC (residue amplification circuit) stages. With the proposed architecture of ADC, SNDR obtained is 85.89 dB, SNR is 85.9 dB and SFDR obtained is 102.8 dB at the sample rate of 100 MHz. This novel architecture of digital correction logic is transparent to the overall system, which is demonstrated by using 14-bit pipelined ADC. After a latency of 14 clocks, digital output will be available at every clock pulse. To describe the circuit behavior of the ADC, VHDL and MATLAB programs are used. The proposed architecture is also capable of reducing the digital hardware. Silicon area is also the complexity of the design. (paper)

  9. Design of a CMOS readout circuit on ultra-thin flexible silicon chip for printed strain gauges

    Directory of Open Access Journals (Sweden)

    M. Elsobky

    2017-09-01

    Full Text Available Flexible electronics represents an emerging technology with features enabling several new applications such as wearable electronics and bendable displays. Precise and high-performance sensors readout chips are crucial for high quality flexible electronic products. In this work, the design of a CMOS readout circuit for an array of printed strain gauges is presented. The ultra-thin readout chip and the printed sensors are combined on a thin Benzocyclobutene/Polyimide (BCB/PI substrate to form a Hybrid System-in-Foil (HySiF, which is used as an electronic skin for robotic applications. Each strain gauge utilizes a Wheatstone bridge circuit, where four Aerosol Jet® printed meander-shaped resistors form a full-bridge topology. The readout chip amplifies the output voltage difference (about 5 mV full-scale swing of the strain gauge. One challenge during the sensor interface circuit design is to compensate for the relatively large dc offset (about 30 mV at 1 mA in the bridge output voltage so that the amplified signal span matches the input range of an analog-to-digital converter (ADC. The circuit design uses the 0. 5 µm mixed-signal GATEFORESTTM technology. In order to achieve the mechanical flexibility, the chip fabrication is based on either back thinned wafers or the ChipFilmTM technology, which enables the manufacturing of silicon chips with a thickness of about 20 µm. The implemented readout chip uses a supply of 5 V and includes a 5-bit digital-to-analog converter (DAC, a differential difference amplifier (DDA, and a 10-bit successive approximation register (SAR ADC. The circuit is simulated across process, supply and temperature corners and the simulation results indicate excellent performance in terms of circuit stability and linearity.

  10. Electronics development for the ATLAS liquid argon calorimeter trigger and readout for future LHC running

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, Walter

    2017-02-11

    The upgrade of the LHC will provide 7 times greater instantaneous and 10 times greater total luminosities than assumed in the original design of the ATLAS Liquid Argon (LAr) Calorimeters. Radiation tolerance criteria and an improved trigger system with higher acceptance rate and longer latency require an upgrade of the LAr readout electronics. In the first upgrade phase in 2019–2020, a trigger readout with up to 10 times higher granularity will be implemented. This allows an improved reconstruction of electromagnetic and hadronic showers and will reduce the background for electron, photon and energy-flow signals at the first trigger level. The analog and digital signal processing components are currently in their final design stages and a fully functional demonstrator system is operated and tested on the LAr Calorimeters. In a second upgrade stage in 2024–2026, the readout of all 183,000 LAr Calorimeter cells will be performed without trigger selection at 40 MHz sampling rate and 16 bit dynamic range. Calibrated energies of all cells will be available at the second trigger level operating at 1 MHz, in order to allow further mitigation of pile-up effects in energy reconstruction. Radiation tolerant, low-power front-end electronics optimized for high pile-up conditions are currently being developed, including pre-amplifier, ADC and serializer components in 65–180 nm technology. This contribution will give an overview of the future LAr readout electronics and present research results from the two upgrade programs.

  11. A Dynamic Range Enhanced Readout Technique with a Two-Step TDC for High Speed Linear CMOS Image Sensors

    Directory of Open Access Journals (Sweden)

    Zhiyuan Gao

    2015-11-01

    Full Text Available This paper presents a dynamic range (DR enhanced readout technique with a two-step time-to-digital converter (TDC for high speed linear CMOS image sensors. A multi-capacitor and self-regulated capacitive trans-impedance amplifier (CTIA structure is employed to extend the dynamic range. The gain of the CTIA is auto adjusted by switching different capacitors to the integration node asynchronously according to the output voltage. A column-parallel ADC based on a two-step TDC is utilized to improve the conversion rate. The conversion is divided into coarse phase and fine phase. An error calibration scheme is also proposed to correct quantization errors caused by propagation delay skew within −Tclk~+Tclk. A linear CMOS image sensor pixel array is designed in the 0.13 μm CMOS process to verify this DR-enhanced high speed readout technique. The post simulation results indicate that the dynamic range of readout circuit is 99.02 dB and the ADC achieves 60.22 dB SNDR and 9.71 bit ENOB at a conversion rate of 2 MS/s after calibration, with 14.04 dB and 2.4 bit improvement, compared with SNDR and ENOB of that without calibration.

  12. An Optimization-Based Reconfigurable Design for a 6-Bit 11-MHz Parallel Pipeline ADC with Double-Sampling S&H

    Directory of Open Access Journals (Sweden)

    Wilmar Carvajal

    2012-01-01

    Full Text Available This paper presents a 6 bit, 11 MS/s time-interleaved pipeline A/D converter design. The specification process, from block level to elementary circuits, is gradually covered to draw a design methodology. Both power consumption and mismatch between the parallel chain elements are intended to be reduced by using some techniques such as double and bottom-plate sampling, fully differential circuits, RSD digital correction, and geometric programming (GP optimization of the elementary analog circuits (OTAs and comparators design. Prelayout simulations of the complete ADC are presented to characterize the designed converter, which consumes 12 mW while sampling a 500 kHz input signal. Moreover, the block inside the ADC with the most stringent requirements in power, speed, and precision was sent to fabrication in a CMOS 0.35 μm AMS technology, and some postlayout results are shown.

  13. A silicon photo-multiplier signal readout using strip-line and waveform sampling for Positron Emission Tomography

    Science.gov (United States)

    Kim, H.; Chen, C.-T.; Eclov, N.; Ronzhin, A.; Murat, P.; Ramberg, E.; Los, S.; Kao, C.-M.

    2016-09-01

    A strip-line and waveform sampling based readout is a signal multiplexing method that can efficiently reduce the readout channels while fully exploiting the fast time characteristics of photo-detectors such as the SiPM. We have applied this readout method for SiPM-based time-of-flight (TOF) positron emission tomography (PET) detectors. We have prototyped strip-line boards in which 8 SiPMs (pitch 5.2 mm) are connected by using a single strip-line, and the signals appearing at the ends of the strip-line are acquired by using the DRS4 waveform sampler at a nominal sampling frequency of 1-5 GS/s. Experimental tests using laser and LYSO scintillator are carried out to assess the performance of the strip-line board. Each SiPM position, which is inferred from the arrival time difference of the two signals at the ends of the strip-line, is well identified with 2.6 mm FWHM resolution when the SiPMs are coupled to LYSO crystals and irradiated by a 22Na source. The average energy and coincidence time resolution corresponding to 511 keV photons are measured to be ∼32% and ∼510 ps FWHM, respectively, at a 5.0 GS/s DRS4 sampling rate. The results show that the sampling rate can be lowered to 1.5 GS/s without performance degradation. These encouraging initial test results indicate that the strip-line and waveform sampling readout method is applicable for SiPM-based TOF PET development.

  14. Temporal Noise Analysis of Charge-Domain Sampling Readout Circuits for CMOS Image Sensors

    Directory of Open Access Journals (Sweden)

    Xiaoliang Ge

    2018-02-01

    Full Text Available This paper presents a temporal noise analysis of charge-domain sampling readout circuits for Complementary Metal-Oxide Semiconductor (CMOS image sensors. In order to address the trade-off between the low input-referred noise and high dynamic range, a Gm-cell-based pixel together with a charge-domain correlated-double sampling (CDS technique has been proposed to provide a way to efficiently embed a tunable conversion gain along the read-out path. Such readout topology, however, operates in a non-stationery large-signal behavior, and the statistical properties of its temporal noise are a function of time. Conventional noise analysis methods for CMOS image sensors are based on steady-state signal models, and therefore cannot be readily applied for Gm-cell-based pixels. In this paper, we develop analysis models for both thermal noise and flicker noise in Gm-cell-based pixels by employing the time-domain linear analysis approach and the non-stationary noise analysis theory, which help to quantitatively evaluate the temporal noise characteristic of Gm-cell-based pixels. Both models were numerically computed in MATLAB using design parameters of a prototype chip, and compared with both simulation and experimental results. The good agreement between the theoretical and measurement results verifies the effectiveness of the proposed noise analysis models.

  15. Reliable and redundant FPGA based read-out design in the ATLAS TileCal Demonstrator

    CERN Document Server

    Åkerstedt, Henrik; The ATLAS collaboration; Drake, Gary; Anderson, Kelby; Bohm, Christian; Oreglia, Mark; Tang, Fukun

    2015-01-01

    The Tile Calorimeter at ATLAS is a hadron calorimeter based on steel plates and scintillating tiles read out by PMTs. The current read-out system uses standard ADCs and custom ASICs to digitize and temporarily store the data on the detector. However, only a subset of the data is actually read out to the counting room. The on-detector electronics will be replaced around 2023. To achieve the required reliability the upgraded system will be highly redundant. Here the ASICs will be replaced with Kintex-7 FPGAs from Xilinx. This, in addition to the use of multiple 10 Gbps optical read-out links, will allow a full read-out of all detector data. Due to the higher radiation levels expected when the beam luminosity is increased, opportunities for repairs will be less frequent. The circuitry and firmware must therefore be designed for sufficiently high reliability using redundancy and radiation tolerant components. Within a year, a hybrid demonstrator including the new read-out system will be installed in one slice of ...

  16. Readout electronics for fine dE/dx sampling with a longitudinal drift chamber

    International Nuclear Information System (INIS)

    Imanishi, A.; Shiino, K.; Ishii, T.; Ohshima, T.; Okuno, H.

    1982-04-01

    A fast, low noise preamplifier, a signal shaping filter and a fast sampling ADC circuit have been developed for fine sampling dE/dx measurement with a longitudinal drift chamber. dE/dx has been sampled with a time interval of 40 ns which corresponds to a gas thickness of 1.4 mm in Ar(90%)/CH 4 (10%). Parameters of each circuit have been adjusted to match with this sampling interval. It is found that the signal tail cancellation is crucial to obtain better dE/dx resolution when the wider drift space is used, and this can be realized with a pole-zero shortening filter and a semi-Gaussian shaping integrator. (author)

  17. Accuracy Limitations of Pipelined ADCs

    NARCIS (Netherlands)

    Quinn, P.J.; Roermund, van A.H.M.

    2005-01-01

    In this paper, the key characteristics of the main errors which affect the performance of a switched capacitor pipelined ADC are presented and their effects on the ADC transfer characteristics demonstrated. Clear and concise relationships are developed to aid optimized design of the pipeline ADC and

  18. Programmable System-on-Chip (PSoC) Embedded Readout Designs for Liquid Helium Level Sensors.

    Science.gov (United States)

    Parasakthi, C; Gireesan, K; Usha Rani, R; Sheela, O K; Janawadkar, M P

    2014-08-01

    This article reports the development of programmable system-on-chip (PSoC)-based embedded readout designs for liquid helium level sensors using resistive liquid vapor discriminators. The system has been built for the measurement of liquid helium level in a concave-bottomed, helmet-shaped, fiber-reinforced plastic cryostat for magnetoencephalography. This design incorporates three carbon resistors as cost-effective sensors, which are mounted at desired heights inside the cryostat and were used to infer the liquid helium level by measuring their temperature-dependent resistance. Localized electrical heating of the carbon resistors was used to discriminate whether the resistor is immersed in liquid helium or its vapor by exploiting the difference in the heat transfer rates in the two environments. This report describes a single PSoC chip for the design and development of a constant current source to drive the three carbon resistors, a multiplexer to route the sensor outputs to the analog-to-digital converter (ADC), a buffer to avoid loading of the sensors, an ADC for digitizing the data, and a display using liquid crystal display cum light-emitting diode modules. The level sensor readout designed with a single PSoC chip enables cost-effective and reliable measurement system design. © 2014 Society for Laboratory Automation and Screening.

  19. A Read-out and Data Acquisition System for the Outputs of Multi-channel Spectroscopy Amplifiers

    International Nuclear Information System (INIS)

    Kong Jie; Qian Yi; Su Hong; Dong Chengfu

    2009-01-01

    A read-out and data acquisition system for the outputs of multi-channel spectroscopy amplifiers is introduced briefly in this paper. The 16-channel gating integrator/multiplexer developed by us and PXI-DAQ card are used to construct this system. A virtual instrument system for displaying, indicating,measuring and recording of output waveform is accomplished by integrating the PC, hardware, software together flexibly based on the Lab Windows/CVI platform in our read-out and data acquisition system. In this system, an ADC can face the 16 outputs of 16-channel spectroscopy amplifiers, which can improve the system integration and reduce the cost of data acquisition system. The design provided a new way for building the read-out and data acquisition system using the normal modules and spectroscopy amplifiers. This system has been tested and demonstrated that it is intelligent, reliable, real-time and low cost. (authors)

  20. A custom front-end ASIC for the readout and timing of 64 SiPM photosensors

    International Nuclear Information System (INIS)

    Bagliesi, M.G.; Avanzini, C.; Bigongiari, G.; Cecchi, R.; Kim, M.Y.; Maestro, P.; Marrocchesi, P.S.; Morsani, F.

    2011-01-01

    A new class of instruments - based on Silicon PhotoMultiplier (SiPM) photosensors - are currently under development for the next generation of Astroparticle Physics experiments in future space missions. A custom front-end ASIC (Application Specific Integrated Circuit) for the readout of 64 SiPM sensors was specified in collaboration with GM-IDEAS (Norway) that designed and manufactured the ASIC. Our group developed a custom readout board equipped with a 16 bit ADC for the digitization of both pulse height and time information. A time stamp, generated by the ASIC in correspondence of the threshold crossing time, is digitized and recorded for each channel. This allows to define a narrow time window around the physics event that reduces significantly the background due to the SiPM dark count rate. In this paper, we report on the preliminary test results obtained with the readout board prototype.

  1. AdcAII of Streptococcus pneumoniae Affects Pneumococcal Invasiveness.

    Directory of Open Access Journals (Sweden)

    Lindsey R Brown

    Full Text Available Across bacterial species, metal binding proteins can serve functions in pathogenesis in addition to regulating metal homeostasis. We have compared and contrasted the activities of zinc (Zn2+-binding lipoproteins AdcA and AdcAII in the Streptococcus pneumoniae TIGR4 background. Exposure to Zn2+-limiting conditions resulted in delayed growth in a strain lacking AdcAII (ΔAdcAII when compared to wild type bacteria or a mutant lacking AdcA (ΔAdcA. AdcAII failed to interact with the extracellular matrix protein laminin despite homology to laminin-binding proteins of related streptococci. Deletion of AdcA or AdcAII led to significantly increased invasion of A549 human lung epithelial cells and a trend toward increased invasion in vivo. Loss of AdcAII, but not AdcA, was shown to negatively impact early colonization of the nasopharynx. Our findings suggest that expression of AdcAII affects invasiveness of S. pneumoniae in response to available Zn2+ concentrations.

  2. Flexible high-speed FASTBUS master for data read-out and preprocessing

    International Nuclear Information System (INIS)

    Wurz, A.; Manner, R.

    1990-01-01

    This paper describes a single slot FASTBUS master module. It can be used for read-out and preprocessing of data that are read out from FASTBUS modules, e.g., and ADC system. The module consists of a 25 MHz, 32-bit processor MC 68030 with cache memory and memory management, a floating point coprocessor MC68882, 4 MBytes of main memory, and FASTBUS master and slave interfaces. In addition, a DMA controller for read-out of FASTBUS data is provided. The processor allows I/O via serial ports, a 16-bit parallel port, and a transputer link. Additional interfaces are planned. The main memory is multi-ported and can be accessed directly by the CPU, the FASTBUS, and external masters via the high-speed local bus that is accessible by way of a connector. The FASTBUS interface supports most of the standard operations in master and slave mode

  3. Development of a multiplexed readout with high position resolution for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sangwon; Choi, Yong [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul 04107 (Korea, Republic of); Kang, Jihoon [Department of Biomedical Engineering, Chonnam National University, Yeosu 550-749 (Korea, Republic of); Jung, Jin Ho [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul 04107 (Korea, Republic of)

    2017-04-01

    Detector signals for positron emission tomography (PET) are commonly multiplexed to reduce the number of digital processing channels so that the system can remain cost effective while also maintaining imaging performance. In this work, a multiplexed readout combining Anger position estimation algorithm and position decoder circuit (PDC) was developed to reduce the number of readout channels by a factor of 24, 96-to-4. The data acquisition module consisted of a TDC (50 ps resolution), 4-channel ADCs (12 bit, 105 MHz sampling rate), 2 GB SDRAM and USB3.0. The performance of the multiplexed readout was assessed with a high-resolution PET detector block composed of 2×3 detector modules, each consisting of an 8×8 array of 1.52×1.52×6 mm{sup 3} LYSO, a 4×4 array of 3×3 mm{sup 2} silicon photomultiplier (SiPM) and 13.4×13.4 mm{sup 2} light guide with 0.7 mm thickness. The acquired flood histogram showed that all 384 crystals could be resolved. The average energy resolution at 511 keV was 13.7±1.6% full-width-at-half-maximum (FWHM) and the peak-to-valley ratios of the flood histogram on the horizontal and vertical lines were 18.8±0.8 and 22.8±1.3, respectively. The coincidence resolving time of a pair of detector blocks was 6.2 ns FWHM. The reconstructed phantom image showed that rods down to a diameter of 1.6 mm could be resolved. The results of this study indicate that the multiplexed readout would be useful in developing a PET with a spatial resolution less than the pixel size of the photosensor, such as a SiPM array.

  4. Improved low-distortion sigma-delta ADC with DWA for WLAN standards

    Energy Technology Data Exchange (ETDEWEB)

    Li Di; Yang Yintang; Zhu Zhangming; Shi Lichun; Wu Xiaofeng; Wang Jiangan, E-mail: lidi2004@126.co [School of Microelectronics, Xidian University, Xi' an 710071 (China)

    2010-02-15

    An improved low distortion sigma-delta ADC (analog-to-digital converter) for wireless local area network standards is presented. A feed-forward MASH 2-2 multi-bit cascaded sigma-delta ADC is adopted; however, this work shows a much better performance than the ADCs which have been presented to date by adding a feedback factor in the second stage to improve the performance of the in-band SNDR (signal to noise and distortion ratio), using 4-bit ADCs in both stages to minimize the quantization noise. Data weighted averaging technology is therefore used to decrease the mismatch noise induced by the 4-bit DACs, which improves the SFDR (spurious free dynamic range) of the ADC. The modulator has been implemented by a 0.18 {mu}m CMOS process and operates at a single 1.8 V supply voltage. Experimental results show that for a 1.25 MHz - -6 dBFS input signal at 160 MHz sampling frequency, the improved ADC with all non-idealities considered achieves a peak SNDR of 80.9 dB and an SFDR of 87 dB, and the effective number of bits is 13.15 bits. (semiconductor integrated circuits)

  5. A new architecture for low-power high-speed pipelined ADCs using double-sampling and opamp-sharing techniques

    NARCIS (Netherlands)

    Abdinia, S.; Yavari, M.

    2009-01-01

    This paper presents a low-voltage low-power pipelined ADC with 1V supply voltage in a 90nm CMOS process. A new architecture is proposed to reduce the power consumption in high-speed pipelined analog-to-digital converters (ADCs). The presented architecture utilizes a combination of two current

  6. SPIROC (SiPM Integrated Read-Out Chip) Dedicated very front-end electronics for an ILC prototype hadronic calorimeter with SiPM read-out

    CERN Document Server

    Bouchel, Michel; Dulucq, Frédéric; Fleury, Julien; de La Taille, Christophe; Martin-Chassard, Gisèle; Raux, Ludovic

    2009-01-01

    The SPIROC chip is a dedicated very front-end electronics for an ILC prototype hadronic calorimeter with Silicon photomultiplier (or MPPC) readout. This ASIC is due to equip a 10,000-channel demonstrator in 2009. SPIROC is an evolution of FLC_SiPM used for the ILC AHCAL physics prototype [1]. SPIROC was submitted in June 2007 and will be tested in September 2007. It embeds cutting edge features that fulfil ILC final detector requirements. It has been realized in 0.35m SiGe technology. It has been developed to match the requirements of large dynamic range, low noise, low consumption, high precision and large number of readout channels needed. SPIROC is an auto-triggered, bi-gain, 36-channel ASIC which allows to measure on each channel the charge from one photoelectron to 2000 and the time with a 100ps accurate TDC. An analogue memory array with a depth of 16 for each channel is used to store the time information and the charge measurement. A 12-bit Wilkinson ADC has been embedded to digitize the analogue memor...

  7. SPIROC (SiPM Integrated Read-Out Chip) Dedicated very front-end electronics for an ILC prototype hadronic calorimeter with SiPM read-out

    CERN Document Server

    Bouchel, Michel; Fleury, Julien; de La Taille, Christophe; Martin-Chassard, Gisèle; Raux, Ludovic

    2007-01-01

    The SPIROC chip is a dedicated very front-end electronics for an ILC prototype hadronic calorimeter with Silicon photomultiplier (or MPPC) readout. This ASIC is due to equip a 10,000-channel demonstrator in 2009. SPIROC is an evolution of FLC_SiPM used for the ILC AHCAL physics prototype [1]. SPIROC was submitted in June 2007 and will be tested in September 2007. It embeds cutting edge features that fulfil ILC final detector requirements. It has been realized in 0.35m SiGe technology. It has been developed to match the requirements of large dynamic range, low noise, low consumption, high precision and large number of readout channels needed. SPIROC is an auto-triggered, bi-gain, 36-channel ASIC which allows to measure on each channel the charge from one photoelectron to 2000 and the time with a 100ps accurate TDC. An analogue memory array with a depth of 16 for each channel is used to store the time information and the charge measurement. A 12-bit Wilkinson ADC has been embedded to digitize the analogue memor...

  8. AVME readout module for multichannel ASIC characterization

    International Nuclear Information System (INIS)

    Borkar, S.P.; Lalwani, S.K.; Ghodgaonkar, M.D.; Kataria, S.K.; Reynaud, Serge; )

    2004-01-01

    Electronics Division, BARC has been working on the development of multi-channel ASIC, called SPAIR (Silicon-strip Pulse Amplifier Integrated Readout). It contains 8 channels of preamplifier, shaper and track-and-hold circuitry. Electronics Division has also actively participated in development of test setup for the front-end ASIC, called PACE, for the preshower detector of the Compact Muon Solenoid (CMS) Experiment at CERN, Geneva. PACE is a 32 channel ASIC for silicon strip detector, containing preamplifier, shaper, calibration circuitry, switched capacitor array, readout amplifier per channel and an analog multiplexer. A VME Readout Module, (VRM) is developed which can be utilized in data acquisition from ASICs like PACE and SPAIR. The VRM can also be used as the Detector Dependent Unit for digitally processing the data received from the front-end electronics on the 16-bit LVDS port. The processed, data can be read by the VME system. Thus the VRM is very useful in building an ASIC characterization system and/or the automated ASIC production testing system. It can be used also to build the applications using such ASICs. To cater to various requirements arising in future, variety of VME modules are to be developed like ADCs, DACs and D 1/0. VME interface remains a common part to all these modules. The different functional blocks of these modules can be designed and fabricated on small piggyback boards (called Test Boards) and mounted on the VRM, which provides the common VME interface. The design details and uses of VRM are presented here. (author)

  9. Mixed species radioiodine air sampling readout and dose assessment system

    International Nuclear Information System (INIS)

    Distenfeld, C.H.; Klemish, J.R. Jr.

    1978-01-01

    This invention provides a simple, reliable, inexpensive and portable means and method for determining the thyroid dose rate of mixed airborne species of solid and gaseous radioiodine without requiring highly skilled personnel, such as health physicists or electronics technicians. To this end, this invention provides a means and method for sampling a gas from a source of a mixed species of solid and gaseous radioiodine for collection of the mixed species and readout and assessment of the emissions therefrom by cylindrically, concentrically and annularly molding the respective species around a cylindrical passage for receiving a conventional probe-type Geiger-Mueller radiation detector

  10. MAROC, a generic photomultiplier readout chip

    Science.gov (United States)

    Blin, S.; Barrillon, P.; de La Taille, C.

    2010-12-01

    The MAROC ASICs family is dedicated to the readout of 64-channel Multi Anode PMT and similar detectors. Its main roles are to correct the gain spread of MAPMT channels thanks to an individual variable gain preamplifier and to discriminate the input signals (from 50fC i.e 1/3 photo-electron) in order to produce 64 trigger outputs. A multiplexed analog charge output is also available with a dynamic range around 10 pe ( ~ 1.6 pC) and a 12 bit Wilkinson ADC is embedded. Three versions of this chip have been submitted. MAROC 2 is the production version for the ATLAS luminometer and MAROC3 is a version with lower dissipation and significant improvements concerning the charge (30 pe: ~ 5 pC) and trigger (discrimination from 10fC). This third version showed very good characteristics that are presented here.

  11. A 64ch readout module for PPD/MPPC/SiPM using EASIROC ASIC

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Isamu, E-mail: isamu.nakamura@kek.jp [KEK, 1-1 Oho Tsukuba 305-0801 (Japan); Ishijima, N.; Hanagaki, K. [Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Yoshimura, K. [Okayama University, 1-1 Tsushimanaka, Kita-ku, Okayama 700-8530 (Japan); Nakai, Y. [Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581 (Japan); Ueno, K. [KEK, 1-1 Oho Tsukuba 305-0801 (Japan)

    2015-07-01

    A readout module for PPD/MPPC/GAPD/SiPM is developed using EASIROC ASIC. The module can handle 64 PPDs and has on-board bias power supply, ADC for energy measurement, 1 ns TDC on FPGA as well as 64ch Logic output for external trigger. Controls and data transfer are through SiTCP technology implemented in FPGA. The module has NIM format for convenience, but can be operated without crate with 5 V AC/DC converter. Basic performance of production module was tested and the results are presented in the poster.

  12. A 10-bit column-parallel cyclic ADC for high-speed CMOS image sensors

    International Nuclear Information System (INIS)

    Han Ye; Li Quanliang; Shi Cong; Wu Nanjian

    2013-01-01

    This paper presents a high-speed column-parallel cyclic analog-to-digital converter (ADC) for a CMOS image sensor. A correlated double sampling (CDS) circuit is integrated in the ADC, which avoids a stand-alone CDS circuit block. An offset cancellation technique is also introduced, which reduces the column fixed-pattern noise (FPN) effectively. One single channel ADC with an area less than 0.02 mm 2 was implemented in a 0.13 μm CMOS image sensor process. The resolution of the proposed ADC is 10-bit, and the conversion rate is 1.6 MS/s. The measured differential nonlinearity and integral nonlinearity are 0.89 LSB and 6.2 LSB together with CDS, respectively. The power consumption from 3.3 V supply is only 0.66 mW. An array of 48 10-bit column-parallel cyclic ADCs was integrated into an array of CMOS image sensor pixels. The measured results indicated that the ADC circuit is suitable for high-speed CMOS image sensors. (semiconductor integrated circuits)

  13. A 0.9-V 12-bit 40-MSPS Pipeline ADC for Wireless Receivers

    Science.gov (United States)

    Ito, Tomohiko; Itakura, Tetsuro

    A 0.9-V 12-bit 40-MSPS pipeline ADC with I/Q amplifier sharing technique is presented for wireless receivers. To achieve high linearity even at 0.9-V supply, the clock signals to sampling switches are boosted over 0.9V in conversion stages. The clock-boosting circuit for lifting these clocks is shared between I-ch ADC and Q-ch ADC, reducing the area penalty. Low supply voltage narrows the available output range of the operational amplifier. A pseudo-differential (PD) amplifier with two-gain-stage common-mode feedback (CMFB) is proposed in views of its wide output range and power efficiency. This ADC is fabricated in 90-nm CMOS technology. At 40MS/s, the measured SNDR is 59.3dB and the corresponding effective number of bits (ENOB) is 9.6. Until Nyquist frequency, the ENOB is kept over 9.3. The ADC dissipates 17.3mW/ch, whose performances are suitable for ADCs for mobile wireless systems such as WLAN/WiMAX.

  14. Studies on sampling and homogeneous dual readout calorimetry with meta-crystals

    CERN Document Server

    Mavromanolakis, G; Lecoq, P

    2011-01-01

    The meta-crystals concept is an approach that consists of using both undoped and properly doped heavy crystal fibers of identical material as the active medium of a calorimeter. The undoped fibers behave as Cherenkov radiators while the doped ones behave as scintillators. A dual readout calorimeter can be built with its sensitive volume composed of a mixture of both types of crystals. In addition if the calorimeter is adequately finely segmented it can also function as a particle flow calorimeter at the same time. In this way one could possibly combine the advantages of both the particle flow concept and the dual readout scheme. We discuss the approach of dual readout calorimetry with meta-crystals made of Lutetium Aluminium Garnet (LuAG). We brie fly present studies on the material development and first testbeam activities and then focus on performance expectation studies based on simulation. We discuss in more detail the results from generic systematic scannings of the design parameters of a dual readout ca...

  15. A study of ADC value in PROPELLER DWI

    International Nuclear Information System (INIS)

    Naka, Takanori; Takahashi, Mitsuyuki

    2009-01-01

    Diffusion weighted imaging (DWI) is rapidly becoming widespread in MRI, with many reports of the differential diagnosis using the Apparent Diffusion Coefficient (ADC) being seen. We examined the influence of scan parameter on ADC in periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)-DWI. Neither the repetition time (TR) nor T1 value had a major influence on the ADC value. Number of motion probing gradient (MPG) pulse, effective echo time (TE), and T2 value were the factors in which the ADC value was changed. In addition, the ADC value has been changed by the scan sequence. The factor that influenced the ADC value was able to be confirmed by this experiment. It is necessary to understand the influence that an individual factor has on ADC. (author)

  16. 14-bit 100 MS/s 121 mW pipelined ADC

    International Nuclear Information System (INIS)

    Chen Yongzhen; Chen Chixiao; Feng Zemin; Ye Fan; Ren Junyan

    2015-01-01

    This paper presents a high-speed high-resolution pipelined ADC with low power and small area. The proposed ADC is designed based on the analysis of the stage scaling theory and the residual amplifiers are shared by two cascading MDACs to reduce power consumption. Shared op-amps with two split input paths are presented in this paper to eliminate the nonlinearity effects such as memory effect and crosstalk. Dynamic pre-amplified comparators are employed to decrease the static power consumption and suppress the kick-back in the comparators. This ADC is implemented in SMIC 0.18 μm CMOS process with an area of 3.1 mm 2 . With a sampling rate of 100 MS/s, spurious-free dynamic range (SFDR) and signal-to-noise plus distortion ratio (SNDR) of the ADC are 82.7 dB and 69.1 dB, respectively. For signals up to 100 MHz, the SFDR and SNDR achieve 81.4 dB and 65.8 dB. The power consumption is 121 mW with a 1.8 V supply voltage. (paper)

  17. A 10-bit 50-MS/s subsampling pipelined ADC based on SMDAC and opamp sharing

    Energy Technology Data Exchange (ETDEWEB)

    Chen Lijie; Zhou Yumei; Wei Baoyue, E-mail: frankdhz@yahoo.com.cn [Institute of Microelectronics, Chinese Academy of Sciences, Beijing 100029 (China)

    2010-11-15

    This paper describes a 10-bit, 50-MS/s pipelined A/D converter (ADC) with proposed area- and power-efficient architecture. The conventional dedicated sample-hold-amplifier (SHA) is eliminated and the matching requirement between the first multiplying digital-to-analog converter (MDAC) and sub-ADC is also avoided by using the SHA merged with the first MDAC (SMDAC) architecture, which features low power and stabilization. Further reduction of power and area is achieved by sharing an opamp between two successive pipelined stages, in which the effect of opamp offset and crosstalk between stages is decreased. So the 10-bit pipelined ADC is realized using just four opamps. The ADC demonstrates a maximum signal-to-noise distortion ratio and spurious free dynamic range of 52.67 dB and 59.44 dB, respectively, with a Nyquist input at full sampling rate. Constant dynamic performance for input frequencies up to 49.7 MHz, which is the twofold Nyquist rate, is achieved at 50 MS/s. The ADC prototype only occupies an active area of 1.81 mm{sup 2} in a 0.35 {mu}m CMOS process, and consumes 133 mW when sampling at 50 MHz from a 3.3-V power supply.

  18. ADC testing using digital stimuli

    NARCIS (Netherlands)

    Sheng, Xiaoqin

    2014-01-01

    The Analogue-to-Digital Converter (ADC) is one of the most typical and widely used mixed-signal circuits. They are applied in video, audio, high-speed communications systems and so on. Many ADCs are integrated into platform-based designs, the architecture which normally contains of standard blocks

  19. ADVANCED READOUT ELECTRONICS FOR MULTIELEMENT CdZnTe SENSORS

    International Nuclear Information System (INIS)

    DE GERONIMO, G.; O CONNOR, P.; KANDASAMY, A.; GROSHOLZ, J.

    2002-01-01

    A generation of high performance front-end and read-out ASICs customized for highly segmented CdZnTe sensors is presented. The ASICs, developed in a multi-year effort at Brookhaven National Laboratory, are targeted to a wide range of applications including medical, safeguards/security, industrial, research, and spectroscopy. The front-end multichannel ASICs provide high accuracy low noise preamplification and filtering of signals, with versions for small and large area CdZnTe elements. They implement a high order unipolar or bipolar shaper, an innovative low noise continuous reset system with self-adapting capability to the wide range of detector leakage currents, a new system for stabilizing the output baseline and high output driving capability. The general-purpose versions include programmable gain and peaking time. The read-out multichannel ASICs provide fully data driven high accuracy amplitude and time measurements, multiplexing and time domain derandomization of the shaped pulses. They implement a fast arbitration scheme and an array of innovative two-phase offset-free rail-to-rail analog peak detectors for buffering and absorption of input rate fluctuations, thus greatly relaxing the rate requirement on the external ADC. Pulse amplitude, hit timing, pulse risetime, and channel address per processed pulse are available at the output in correspondence of an external readout request. Prototype chips have been fabricated in 0.5 and 0.35 (micro)m CMOS and tested. Design concepts and experimental results are discussed

  20. MAROC, a generic photomultiplier readout chip

    Energy Technology Data Exchange (ETDEWEB)

    Blin, S; Barrillon, P; La Taille, C de, E-mail: blin@lal.in2p3.f [CNRS/IN2p3/LAL-OMEGA, Universite Paris Sud, Bat.200, 91898 Orsay (France)

    2010-12-15

    The MAROC ASICs family is dedicated to the readout of 64-channel Multi Anode PMT and similar detectors. Its main roles are to correct the gain spread of MAPMT channels thanks to an individual variable gain preamplifier and to discriminate the input signals (from 50fC i.e 1/3 photo-electron) in order to produce 64 trigger outputs. A multiplexed analog charge output is also available with a dynamic range around 10 pe ( {approx} 1.6 pC) and a 12 bit Wilkinson ADC is embedded. Three versions of this chip have been submitted. MAROC 2 is the production version for the ATLAS luminometer and MAROC3 is a version with lower dissipation and significant improvements concerning the charge (30 pe: {approx} 5 pC) and trigger (discrimination from 10fC). This third version showed very good characteristics that are presented here.

  1. MAROC, a generic photomultiplier readout chip

    International Nuclear Information System (INIS)

    Blin, S; Barrillon, P; La Taille, C de

    2010-01-01

    The MAROC ASICs family is dedicated to the readout of 64-channel Multi Anode PMT and similar detectors. Its main roles are to correct the gain spread of MAPMT channels thanks to an individual variable gain preamplifier and to discriminate the input signals (from 50fC i.e 1/3 photo-electron) in order to produce 64 trigger outputs. A multiplexed analog charge output is also available with a dynamic range around 10 pe ( ∼ 1.6 pC) and a 12 bit Wilkinson ADC is embedded. Three versions of this chip have been submitted. MAROC 2 is the production version for the ATLAS luminometer and MAROC3 is a version with lower dissipation and significant improvements concerning the charge (30 pe: ∼ 5 pC) and trigger (discrimination from 10fC). This third version showed very good characteristics that are presented here.

  2. Pseudo Asynchronous Level Crossing adc for ecg Signal Acquisition.

    Science.gov (United States)

    Marisa, T; Niederhauser, T; Haeberlin, A; Wildhaber, R A; Vogel, R; Goette, J; Jacomet, M

    2017-02-07

    A new pseudo asynchronous level crossing analogue-to-digital converter (adc) architecture targeted for low-power, implantable, long-term biomedical sensing applications is presented. In contrast to most of the existing asynchronous level crossing adc designs, the proposed design has no digital-to-analogue converter (dac) and no continuous time comparators. Instead, the proposed architecture uses an analogue memory cell and dynamic comparators. The architecture retains the signal activity dependent sampling operation by generating events only when the input signal is changing. The architecture offers the advantages of smaller chip area, energy saving and fewer analogue system components. Beside lower energy consumption the use of dynamic comparators results in a more robust performance in noise conditions. Moreover, dynamic comparators make interfacing the asynchronous level crossing system to synchronous processing blocks simpler. The proposed adc was implemented in [Formula: see text] complementary metal-oxide-semiconductor (cmos) technology, the hardware occupies a chip area of 0.0372 mm 2 and operates from a supply voltage of [Formula: see text] to [Formula: see text]. The adc's power consumption is as low as 0.6 μW with signal bandwidth from [Formula: see text] to [Formula: see text] and achieves an equivalent number of bits (enob) of up to 8 bits.

  3. High Performance ADC for Reconfigurable/Reprogrammable Communication Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop Group will develop a 3X improvement in sampling resolution over current state-of-the art analog-to-digital converter (ADC) technology to support...

  4. An undersampling 14-bit cyclic ADC with over 100-dB SFDR

    Energy Technology Data Exchange (ETDEWEB)

    Li Weitao; Li Fule; Guo Dandan; Zhang Chun; Wang Zhihua, E-mail: liwt07@mails.tsinghua.edu.c [Institute of Microelectronics, Tsinghua University, Beijing 100084 (China)

    2010-02-15

    A high linearity, undersampling 14-bit 357 kSps cyclic analog-to-digital convert (ADC) is designed for a radio frequency identification transceiver system. The passive capacitor error-average (PCEA) technique is adopted for high accuracy. An improved PCEA sampling network, capable of eliminating the crosstalk path of two pipelined stages, is employed. Opamp sharing and the removal of the front-end sample and hold amplifier are utilized for low power dissipation and small chip area. An additional digital calibration block is added to compensate for the error due to defective layout design. The presented ADC is fabricated in a 180 nm CMOS process, occupying 0.65 x 1.6 mm{sup 2}. The input of the undersampling ADC achieves 15.5 MHz with more than 90 dB spurious free dynamic range (SFDR), and the peak SFDR is as high as 106.4 dB with 2.431 MHz input. (semiconductor integrated circuits)

  5. Histogram analysis derived from apparent diffusion coefficient (ADC) is more sensitive to reflect serological parameters in myositis than conventional ADC analysis.

    Science.gov (United States)

    Meyer, Hans Jonas; Emmer, Alexander; Kornhuber, Malte; Surov, Alexey

    2018-05-01

    Diffusion-weighted imaging (DWI) has the potential of being able to reflect histopathology architecture. A novel imaging approach, namely histogram analysis, is used to further characterize tissues on MRI. The aim of this study was to correlate histogram parameters derived from apparent diffusion coefficient (ADC) maps with serological parameters in myositis. 16 patients with autoimmune myositis were included in this retrospective study. DWI was obtained on a 1.5 T scanner by using the b-values of 0 and 1000 s mm - 2 . Histogram analysis was performed as a whole muscle measurement by using a custom-made Matlab-based application. The following ADC histogram parameters were estimated: ADCmean, ADCmax, ADCmin, ADCmedian, ADCmode, and the following percentiles ADCp10, ADCp25, ADCp75, ADCp90, as well histogram parameters kurtosis, skewness, and entropy. In all patients, the blood sample was acquired within 3 days to the MRI. The following serological parameters were estimated: alanine aminotransferase, aspartate aminotransferase, creatine kinase, lactate dehydrogenase, C-reactive protein (CRP) and myoglobin. All patients were screened for Jo1-autobodies. Kurtosis correlated inversely with CRP (p = -0.55 and 0.03). Furthermore, ADCp10 and ADCp90 values tended to correlate with creatine kinase (p = -0.43, 0.11, and p = -0.42, = 0.12 respectively). In addition, ADCmean, p10, p25, median, mode, and entropy were different between Jo1-positive and Jo1-negative patients. ADC histogram parameters are sensitive for detection of muscle alterations in myositis patients. Advances in knowledge: This study identified that kurtosis derived from ADC maps is associated with CRP in myositis patients. Furthermore, several ADC histogram parameters are statistically different between Jo1-positive and Jo1-negative patients.

  6. Comparison of Absolute Apparent Diffusion Coefficient (ADC) Values in ADC Maps Generated Across Different Postprocessing Software: Reproducibility in Endometrial Carcinoma.

    Science.gov (United States)

    Ghosh, Adarsh; Singh, Tulika; Singla, Veenu; Bagga, Rashmi; Khandelwal, Niranjan

    2017-12-01

    Apparent diffusion coefficient (ADC) maps are usually generated by builtin software provided by the MRI scanner vendors; however, various open-source postprocessing software packages are available for image manipulation and parametric map generation. The purpose of this study is to establish the reproducibility of absolute ADC values obtained using different postprocessing software programs. DW images with three b values were obtained with a 1.5-T MRI scanner, and the trace images were obtained. ADC maps were automatically generated by the in-line software provided by the vendor during image generation and were also separately generated on postprocessing software. These ADC maps were compared on the basis of ROIs using paired t test, Bland-Altman plot, mountain plot, and Passing-Bablok regression plot. There was a statistically significant difference in the mean ADC values obtained from the different postprocessing software programs when the same baseline trace DW images were used for the ADC map generation. For using ADC values as a quantitative cutoff for histologic characterization of tissues, standardization of the postprocessing algorithm is essential across processing software packages, especially in view of the implementation of vendor-neutral archiving.

  7. Interpolation algorithm for asynchronous ADC-data

    Directory of Open Access Journals (Sweden)

    S. Bramburger

    2017-09-01

    Full Text Available This paper presents a modified interpolation algorithm for signals with variable data rate from asynchronous ADCs. The Adaptive weights Conjugate gradient Toeplitz matrix (ACT algorithm is extended to operate with a continuous data stream. An additional preprocessing of data with constant and linear sections and a weighted overlap of step-by-step into spectral domain transformed signals improve the reconstruction of the asycnhronous ADC signal. The interpolation method can be used if asynchronous ADC data is fed into synchronous digital signal processing.

  8. Photoproduction {gamma}p{yields}p{pi}{sup 0}{pi}{sup 0}. Results and development of a fast FADC-readout for double polarization experiments; Photoproduktion {gamma}p{yields}p{pi}{sup 0}{pi}{sup 0}. Ergebnisse und Entwicklung einer schnellen FADC-Auslesse fuer Doppelpolarisationsexpermente

    Energy Technology Data Exchange (ETDEWEB)

    Szczepanek, T.

    2006-07-01

    This thesis describes the development and testing of a very fast intersection card for the driving and readout of a struck DL300 flash-ADC system. In order to permit an as fast as possible processing and storage of the data, an intersection on the base of a field-programmable integrated circuit was developed, which is placed on PCI/PMC plug-card together with fast memory and can transmit the data to the readout processor via a direct storage transmission from the memory of the control card to the applied CPU. The readout of the DL300 system pursues thereby autonomeously on the integrated circuit. First test measurements in the laboratory show that the flash ADC readout is functionable and dtat rates of 1 kHz or more can be reached. Furthermore the establishment of a graphical control software for the data-acquisition system in combination with a system for the processing, storage, and display of status informations of the data acquisition as well as a hardware synchronization module and an interrupt module on the base of a serial RS-232 intersection for the Linux kernel are presented, which were also developed in the framework of this thesis.

  9. A 72-dB-SNDR rail-to-rail successive approximation ADC using mismatch calibration techniques

    International Nuclear Information System (INIS)

    Liu Yan; Hua Siliang; Wang Donghui; Hou Chaohuan

    2012-01-01

    When the voltage of an analog input signal is equal to the supply voltage, it is difficult for a conventional successive approximation ADC to correctly convert the analog signal into digital signal. This paper introduces an improved successive approximation ADC, which can convert the rail-to-rail input range and reduce sampling time through a track-and-hold circuit. Comparator offset cancellation and capacitor self-calibration techniques are used in this ADC. Measurement results show that the peak SNDR of this ADC reaches 72 dB and the signal effective bandwidth is up to 1.25 MHz. It consumes 1 mW in the test, and the figure of merit is 123 fJ/conversion-step. (semiconductor integrated circuits)

  10. ADC mapping of benign and malignant breast tumors

    International Nuclear Information System (INIS)

    Woodhams, R.; Matsunaga, Keiji; Kan, Shinichi; Hata, Hirofumi; Iwabuchi, Keiichi; Kuranami, Masaru; Watanabe, Masahiko; Hayakawa, Kazushige; Ozaki, Masanori

    2005-01-01

    The purpose of this study was to investigate the utility of diffusion-weighted imaging (DWI) and the apparent diffusion coefficient (ADC) value in differentiating benign and malignant breast lesions and evaluating the detection accuracy of the cancer extension. We used DWI to obtain images of 191 benign and malignant lesions (24 benign, 167 malignant) before surgical excision. The ADC values of the benign and malignant lesions were compared, as were the values of noninvasive ductal carcinoma (NIDC) and invasive ductal carcinoma (IDC). We also evaluated the ADC map, which represents the distribution of ADC values, and compared it with the cancer extension. The mean ADC value of each type of lesion was as follows: malignant lesions, 1.22±0.31 x 10 -3 mm 2 /s; benign lesions, 1.67±0.54 x 10 -3 mm 2 /s; normal tissues, 2.09±0.27 x 10 -3 mm 2 /s. The mean ADC value of the malignant lesions was statistically lower than that of the benign lesions and normal breast tissues. The ADC value of IDC was statistically lower than that of NIDC. The sensitivity of the ADC value for malignant lesions with a threshold of less than 1.6 x 10 -3 mm 2 /s was 95% and the specificity was 46%. A full 75% of all malignant cases exhibited a near precise distribution of low ADC values on ADC maps to describe malignant lesions. The main causes of false negative and underestimation of cancer spread were susceptibility artifact because of bleeding and tumor structure. Major histologic types of false-positive lesions were intraductal papilloma and fibrocystic diseases. Fibrocystic diseases also resulted in overestimation of cancer extension. DWI has the potential in clinical appreciation to detect malignant breast tumors and support the evaluation of tumor extension. However, the benign proliferative change remains to be studied as it mimics the malignant phenomenon on the ADC map. (author)

  11. Design of a readout ASIC for gas detectors with self-amplification

    International Nuclear Information System (INIS)

    Deng Zhi; Liu Yinong

    2009-01-01

    A readout ASIC has been designed for gas detectors with self-amplification such as GEM and RPC. It provides amplification and shaping of the detector signals and buffers them to the free running ADCs. The charge gain and the shaping time can be adjusted. The programmability of gain and shaping time is very convenient for studying detector performance under different gas gain and also expands the application range of the chip. The ENC increases as charge gain decreases below 10 mV/fC because the noise from the shaper becomes significant. The chip is designed in Chartered 0.35μm 2P4M CMOS process. Detailed design and simulation results are described in the paper. (authors)

  12. Phase-I Trigger Readout Electronics Upgrade of the ATLAS Liquid-Argon Calorimeters

    CERN Document Server

    Mori, Tatsuya; The ATLAS collaboration

    2015-01-01

    The Large Hadron Collider (LHC) is foreseen to be upgraded during the shut-down period of 2018-2019 to deliver about 3 times the instantaneous design luminosity. Since the ATLAS trigger system, at that time, will not support such an increase of the trigger rate an improvement of the trigger system is required. The ATLAS LAr Calorimeter readout will therefore be modified and digital trigger signals with a higher spatial granularity will be provided to the trigger. The new trigger signals will be arranged in 34000 Super Cells which achieves a 5-10 better granularity than the trigger towers currently used and allows an improved background rejection. The Super Cell readout is composed of custom developed 12-bit combined SAR ADCs in 130 nm CMOS technology which will be installed on-detector in a radiation environment and digitizes the detector pulses at 40 MHz. The data will be transmitted to the back end using a custom serializer and optical converter applying 5.44 Gb/s optical links. These components are install...

  13. Desain Layout 1-Stage ADC Pipeline 80Msps dengan Mentor Graphics 0,35µm untuk Aplikasi Kamera Kecepatan Tinggi

    Directory of Open Access Journals (Sweden)

    Hamzah Afandi

    2012-10-01

    Full Text Available Design layout 1-stage pipeline is part of the 8-stage pipeline 80 Msps ADC. Layout 1-stage pipeline consists of 3 units : op-amp, switch capacitor, precision comparator with latch. Pipeline ADC works gradually and requires synchronization of digital output 8 stage by using a unit delay circuit (D-FF. Pipeline ADC requires pulse rate (clockgenerator to support its work. Units OP-AMP transconductance CMOS components designed with the correct specification ADC applications with capacitive loads, with a large input impedance and minimize noise. The precision comparator has Vos(offset voltage approximately equal to 0V. The capacitor switch designs use NMOS switch as a switch for the sampling and multiplying. In the sampling phase and multiplying processes, the ADC requires a clock pulse with a non-intersect mode (lapping. The width of non-overlapping period was adjusted to the time of constance in the sampling process and multiplying. The total number of each pulse period equal to 12.5 ns or equal to the frequency of 80MHz. In the 1-stage layout an additional correction capacitor was required to correct residual voltage. The total area of the layout 1-stage pipeline ADC is 1-bit 200 μm x 98μm.

  14. Changes in ADC Caused by Tensile Loading of Rabbit Achilles Tendon: Evidence for Water Transport

    Science.gov (United States)

    Han, S.; Gemmell, S. J.; Helmer, K. G.; Grigg, P.; Wellen, J. W.; Hoffman, A. H.; Sotak, C. H.

    2000-06-01

    Water diffusion measurements were performed on rabbit Achilles tendons during static tensile loading and tendons in an unloaded state. The apparent diffusion coefficient (ADC) was measured along two directions: parallel and perpendicular to the long axis of the tendon. Tendons were studied after being prepared in two ways: (a) after being stored frozen in phosphate-buffered saline (PBS) and (b) freshly isolated. Statistically significant directional anisotropy was observed in the ADC in all tendons. The ADC was significantly greater in the direction parallel to the long axis of the tendon than in the perpendicular direction. The anisotropy is attributed to the greater restrictions seen by the water molecules in the perpendicular direction and is consistent with the known geometry of the tendon. Storage in PBS caused tendons to swell. This increased the ADC measured along both directions and reduced the anisotropy. The existence of anisotropy in the ADC was not related to the orientation of the specimen in the magnet. The ADC increased along both directions following the application of a 5-N tensile load; the increase was greatest along the perpendicular axis of the tendon. In order to determine whether load-related changes in the ADC reflected changes in interfibrilar spacing, we used electron microscopy to measure load-related changes in fibril spacing. Load-related changes in fiber spacing could not account for the observed changes in the ADC. The increase in ADC caused by loading was attributed to the extrusion of tendon water into a bulk phase along the outside surface of the tendon. In PBS-stored samples, enough fluid was extruded that it could be visualized. The transient response of the ADC to a 5-N tensile load was also studied. The absolute ADC in both directions increased with loading and recovered to baseline upon unloading. The transient changes in ADC, for both loading and unloading, had a mean time constant of approximately 15 min. The magnitude of

  15. A 10-bit 120-MS/s pipelined ADC with improved switch and layout scaling strategy

    International Nuclear Information System (INIS)

    Zhou Jia; Xu Lili; Li Fule; Wang Zhihua

    2015-01-01

    A 10 bit, 120 MS/s two-channel pipelined analog-to digital converter (ADC) is presented. The ADC is featured with improved switch by using the body effect to improve its conduction performance. A scaling down strategy is proposed to get more efficiency in the OTAs layout design. Implemented in a 0.18-μm CMOS technology, the ADC's prototype occupied an area of 2.05 × 1.83 mm 2 . With a sampling rate of 120-MS/s and an input of 4.9 MHz, the ADC achieves a spurious-free-dynamic range of 74.32 dB and signal-to-noise-and-distortion ratio of 55.34 dB, while consuming 220-mW/channel at 3-V supply. (paper)

  16. Different methods of measuring ADC values in normal human brain

    International Nuclear Information System (INIS)

    Wei Youping; Sheng Junkang; Zhang Caiyuan

    2009-01-01

    Objective: To investigate better method of measuring ADC values of normal brain, and provide reference for further research. Methods: Twenty healthy people's MR imaging were reviewed. All of them underwent routine MRI scans and echo-planar diffusion-weighted imaging (DWI), and ADC maps were reconstructed on work station. Six regions of interest (ROI) were selected for each object, the mean ADC values were obtained for each position on DWI and ADC maps respectively. Results: On the anisotropic DWI map calculated in the hypothalamus, ADC M , ADC P , ADC S values were no significant difference (P>0.05), in the frontal white matter and internal capsule hindlimb, there was a significant difference (P ave value exist significant difference to direct measurement on the anisotropic (isotropic) ADC map (P<0.001). Conclusion: Diffusion of water in the frontal white matter and internal capsule are anisotropic, but it is isotropic in the hypothalamus; different quantitative methods of diffusion measurement of 4ADC values have significant difference, but ADC values calculated through the DWI map is more accurate, quantitative diffusion study of brain tissue should also consider the diffusion measurement method. (authors)

  17. Volumetric segmentation of ADC maps and utility of standard deviation as measure of tumor heterogeneity in soft tissue tumors.

    Science.gov (United States)

    Singer, Adam D; Pattany, Pradip M; Fayad, Laura M; Tresley, Jonathan; Subhawong, Ty K

    2016-01-01

    Determine interobserver concordance of semiautomated three-dimensional volumetric and two-dimensional manual measurements of apparent diffusion coefficient (ADC) values in soft tissue masses (STMs) and explore standard deviation (SD) as a measure of tumor ADC heterogeneity. Concordance correlation coefficients for mean ADC increased with more extensive sampling. Agreement on the SD of tumor ADC values was better for large regions of interest and multislice methods. Correlation between mean and SD ADC was low, suggesting that these parameters are relatively independent. Mean ADC of STMs can be determined by volumetric quantification with high interobserver agreement. STM heterogeneity merits further investigation as a potential imaging biomarker that complements other functional magnetic resonance imaging parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Modifications of the optical properties for DAM-ADC nuclear track detector exposed to alpha particles

    Science.gov (United States)

    Rammah, Y. S.; Awad, E. M.

    2018-05-01

    Modifications of the optical properties of diallyl maleate-allyl diglycol carbonate (DAM-ADC) nuclear detector induced by alpha particles are described. DAM-ADC samples were irradiated perpendicularly by thin 241Am disk source that emits alpha particles with 5.48 MeV. The optical absorption has been measured using the ultraviolet-visible (UV-1100) spectroscopy. It was found that DAM-ADC polymer shows substantial modifications in its optical characteristics upon irradiated with alpha particles with different energies. The optical energy band gap (Egap) for the detector was calculated for the direct and the indirect allowed transitions in K-space using two approaches (Tauc's model and absorption spectrum fitting (ASF) method). Urbach's energy (Ea), number of carbon atoms per conjugated length (N), number of carbon atoms per cluster (M), and refractive index (n) for the present samples were determined. Results reveal that the values of energy gap in direct transition are greater than those of indirect, before and after irradiation. (Egap), (Ea), (N), (M), and (n) of the present samples are changed significantly with irradiation time and value of alpha energy. Results reflect the possibility of using DAM-ADC polymer track detectors to estimate alpha particle energies using the variation of the absorbance.

  19. Basic Block of Pipelined ADC Design Requirements

    Directory of Open Access Journals (Sweden)

    V. Kledrowetz

    2011-04-01

    Full Text Available The paper describes design requirements of a basic stage (called MDAC - Multiplying Digital-to- Analog Converter of a pipelined ADC. There exist error sources such as finite DC gain of opamp, capacitor mismatch, thermal noise, etc., arising when the switched capacitor (SC technique and CMOS technology are used. These non-idealities are explained and their influences on overall parameters of a pipelined ADC are studied. The pipelined ADC including non-idealities was modeled in MATLAB - Simulink simulation environment.

  20. Novel active signal compression in low-noise analog readout at future X-ray FEL facilities

    Science.gov (United States)

    Manghisoni, M.; Comotti, D.; Gaioni, L.; Lodola, L.; Ratti, L.; Re, V.; Traversi, G.; Vacchi, C.

    2015-04-01

    This work presents the design of a low-noise front-end implementing a novel active signal compression technique. This feature can be exploited in the design of analog readout channels for application to the next generation free electron laser (FEL) experiments. The readout architecture includes the low-noise charge sensitive amplifier (CSA) with dynamic signal compression, a time variant shaper used to process the signal at the preamplifier output and a 10-bit successive approximation register (SAR) analog-to-digital converter (ADC). The channel will be operated in such a way to cope with the high frame rate (exceeding 1 MHz) foreseen for future XFEL machines. The choice of a 65 nm CMOS technology has been made in order to include all the building blocks in the target pixel pitch of 100 μm. This work has been carried out in the frame of the PixFEL Project funded by the Istituto Nazionale di Fisica Nucleare (INFN), Italy.

  1. Adjustable Nyquist-rate System for Single-Bit Sigma-Delta ADC with Alternative FIR Architecture

    Science.gov (United States)

    Frick, Vincent; Dadouche, Foudil; Berviller, Hervé

    2016-09-01

    This paper presents a new smart and compact system dedicated to control the output sampling frequency of an analogue-to-digital converters (ADC) based on single-bit sigma-delta (ΣΔ) modulator. This system dramatically improves the spectral analysis capabilities of power network analysers (power meters) by adjusting the ADC's sampling frequency to the input signal's fundamental frequency with a few parts per million accuracy. The trade-off between straightforwardness and performance that motivated the choice of the ADC's architecture are preliminary discussed. It particularly comes along with design considerations of an ultra-steep direct-form FIR that is optimised in terms of size and operating speed. Thanks to compact standard VHDL language description, the architecture of the proposed system is particularly suitable for application-specific integrated circuit (ASIC) implementation-oriented low-power and low-cost power meter applications. Field programmable gate array (FPGA) prototyping and experimental results validate the adjustable sampling frequency concept. They also show that the system can perform better in terms of implementation and power capabilities compared to dedicated IP resources.

  2. Precision Instrumentation Amplifiers and Read-Out Integrated Circuits

    CERN Document Server

    Wu, Rong; Makinwa, Kofi A A

    2013-01-01

    This book presents innovative solutions in the design of precision instrumentation amplifier and read-out ICs, which can be used to boost millivolt-level signals transmitted by modern sensors, to levels compatible with the input ranges of typical Analog-to-Digital Converters (ADCs).  The discussion includes the theory, design and realization of interface electronics for bridge transducers and thermocouples. It describes the use of power efficient techniques to mitigate low frequency errors, resulting in interface electronics with high accuracy, low noise and low drift. Since this book is mainly about techniques for eliminating low frequency errors, it describes the nature of these errors and the associated dynamic offset cancellation techniques used to mitigate them.  Surveys comprehensively offset cancellation and accuracy improvement techniques applied in precision amplifier designs; Presents techniques in precision circuit design to mitigate low frequency errors in millivolt-level signals transmitted by ...

  3. Circuit and method for comparator offset error detection and correction in ADC

    NARCIS (Netherlands)

    2017-01-01

    PROBLEM TO BE SOLVED: To provide a method for calibrating an analog-to-digital converter (ADC).SOLUTION: The method comprises: sampling an input voltage signal; comparing the sampled input voltage signal with an output signal of a feedback digital-to-analog converter (DAC) 40; determining in a

  4. 12-bit 32 channel 500 MS/s low-latency ADC for particle accelerators real-time control

    Science.gov (United States)

    Karnitski, Anton; Baranauskas, Dalius; Zelenin, Denis; Baranauskas, Gytis; Zhankevich, Alexander; Gill, Chris

    2017-09-01

    Particle beam control systems require real-time low latency digital feedback with high linearity and dynamic range. Densely packed electronic systems employ high performance multichannel digitizers causing excessive heat dissipation. Therefore, low power dissipation is another critical requirement for these digitizers. A described 12-bit 500 MS/s ADC employs a sub-ranging architecture based on a merged sample & hold circuit, a residue C-DAC and a shared 6-bit flash core ADC. The core ADC provides a sequential coarse and fine digitization featuring a latency of two clock cycles. The ADC is implemented in a 28 nm CMOS process and consumes 4 mW of power per channel from a 0.9 V supply (interfacing and peripheral circuits are excluded). Reduced power consumption and small on-chip area permits the implementation of 32 ADC channels on a 10.7 mm2 chip. The ADC includes a JESD204B standard compliant output data interface operated at the 7.5 Gbps/ch rate. To minimize the data interface related time latency, a special feature permitting to bypass the JESD204B interface is built in. DoE Phase I Award Number: DE-SC0017213.

  5. A 172 $\\mu$W Compressively Sampled Photoplethysmographic (PPG) Readout ASIC With Heart Rate Estimation Directly From Compressively Sampled Data.

    Science.gov (United States)

    Pamula, Venkata Rajesh; Valero-Sarmiento, Jose Manuel; Yan, Long; Bozkurt, Alper; Hoof, Chris Van; Helleputte, Nick Van; Yazicioglu, Refet Firat; Verhelst, Marian

    2017-06-01

    A compressive sampling (CS) photoplethysmographic (PPG) readout with embedded feature extraction to estimate heart rate (HR) directly from compressively sampled data is presented. It integrates a low-power analog front end together with a digital back end to perform feature extraction to estimate the average HR over a 4 s interval directly from compressively sampled PPG data. The application-specified integrated circuit (ASIC) supports uniform sampling mode (1x compression) as well as CS modes with compression ratios of 8x, 10x, and 30x. CS is performed through nonuniformly subsampling the PPG signal, while feature extraction is performed using least square spectral fitting through Lomb-Scargle periodogram. The ASIC consumes 172  μ W of power from a 1.2 V supply while reducing the relative LED driver power consumption by up to 30 times without significant loss of relevant information for accurate HR estimation.

  6. Toward VIP-PIX: A Low Noise Readout ASIC for Pixelated CdTe Gamma-Ray Detectors for Use in the Next Generation of PET Scanners.

    Science.gov (United States)

    Macias-Montero, Jose-Gabriel; Sarraj, Maher; Chmeissani, Mokhtar; Puigdengoles, Carles; Lorenzo, Gianluca De; Martínez, Ricardo

    2013-08-01

    VIP-PIX will be a low noise and low power pixel readout electronics with digital output for pixelated Cadmium Telluride (CdTe) detectors. The proposed pixel will be part of a 2D pixel-array detector for various types of nuclear medicine imaging devices such as positron-emission tomography (PET) scanners, Compton gamma cameras, and positron-emission mammography (PEM) scanners. Each pixel will include a SAR ADC that provides the energy deposited with 10-bit resolution. Simultaneously, the self-triggered pixel which will be connected to a global time-to-digital converter (TDC) with 1 ns resolution will provide the event's time stamp. The analog part of the readout chain and the ADC have been fabricated with TSMC 0.25 μ m mixed-signal CMOS technology and characterized with an external test pulse. The power consumption of these parts is 200 μ W from a 2.5 V supply. It offers 4 switchable gains from ±10 mV/fC to ±40 mV/fC and an input charge dynamic range of up to ±70 fC for the minimum gain for both polarities. Based on noise measurements, the expected equivalent noise charge (ENC) is 65 e - RMS at room temperature.

  7. Cerebral and cerebellar ADC values during a migraine attack

    Energy Technology Data Exchange (ETDEWEB)

    Degirmenci, Bumin; Haktanir, Alpay; Albayrak, Ramazan; Acar, Murat [University of Kocatepe, Department of Radiology, Faculty of Medicine, Afyon (Turkey); Yaman, Mehmet [University of Kocatepe, Department of Neurology, Faculty of Medicine, Afyon (Turkey)

    2007-05-15

    We investigated the diffusion-weighted MRI changes, apparent diffusion coefficient (ADC) values, and conventional MRI findings in specific brain areas during migraine attacks in patients with and without aura. Included in the study were 22 patients (2 male, 20 female) aged between 17 and 49 years who were diagnosed as having migraine according to the diagnostic criteria of the International Headache Society. Also included in the study were 18 age- and sex-matched healthy volunteers. Hyperintense lesions were evaluated in conventional MR images. Heavily diffusion-weighted images, ADC maps, and segmented ADC maps generated for regional ADC (rADC) measurements, were also studied. ADC values from specific brain areas were used with appropriate region of interests (ROI). Migraine with aura was diagnosed in 13 patients and migraine without aura was diagnosed in 9 patients. A total of 23 hyperintense lesions within the periventricular white matter and deep white matter were detected in five patients (21.8%). All of these hyperintense lesions were seen in migraine patients with aura. In only one patient did a hyperintense lesion show an increased diffusion pattern on diffusion-weighted images and ADC maps. One hyperintense lesion was detected in the control group (5.5%). There was no significant difference in ADC values between the migraine and control groups. T2-weighted hyperintense lesions were significantly more frequent in migraine patients especially in those with aura than in the control group. No diffusion alterations in diffusion-weighted images were detected in the infra- and supratentorial brain areas during migraine attacks in patients with and without aura. (orig.)

  8. Cerebral and cerebellar ADC values during a migraine attack

    International Nuclear Information System (INIS)

    Degirmenci, Bumin; Haktanir, Alpay; Albayrak, Ramazan; Acar, Murat; Yaman, Mehmet

    2007-01-01

    We investigated the diffusion-weighted MRI changes, apparent diffusion coefficient (ADC) values, and conventional MRI findings in specific brain areas during migraine attacks in patients with and without aura. Included in the study were 22 patients (2 male, 20 female) aged between 17 and 49 years who were diagnosed as having migraine according to the diagnostic criteria of the International Headache Society. Also included in the study were 18 age- and sex-matched healthy volunteers. Hyperintense lesions were evaluated in conventional MR images. Heavily diffusion-weighted images, ADC maps, and segmented ADC maps generated for regional ADC (rADC) measurements, were also studied. ADC values from specific brain areas were used with appropriate region of interests (ROI). Migraine with aura was diagnosed in 13 patients and migraine without aura was diagnosed in 9 patients. A total of 23 hyperintense lesions within the periventricular white matter and deep white matter were detected in five patients (21.8%). All of these hyperintense lesions were seen in migraine patients with aura. In only one patient did a hyperintense lesion show an increased diffusion pattern on diffusion-weighted images and ADC maps. One hyperintense lesion was detected in the control group (5.5%). There was no significant difference in ADC values between the migraine and control groups. T2-weighted hyperintense lesions were significantly more frequent in migraine patients especially in those with aura than in the control group. No diffusion alterations in diffusion-weighted images were detected in the infra- and supratentorial brain areas during migraine attacks in patients with and without aura. (orig.)

  9. Triroc: A Multi-Channel SiPM Read-Out ASIC for PET/PET-ToF Application

    Science.gov (United States)

    Ahmad, Salleh; Fleury, Julien; de la Taille, Christophe; Seguin-Moreau, Nathalie; Dulucq, Frederic; Martin-Chassard, Gisele; Callier, Stephane; Thienpont, Damien; Raux, Ludovic

    2015-06-01

    Triroc is the latest addition to SiPM readout ASICs family developed at Weeroc, a start-up company from the Omega microelectronics group of IN2P3/CNRS. This chip is developed under the framework TRIMAGE European project which is aimed for building a cost effective tri-modal PET/MR/EEG brain scan. To ensure the flexibility and compatibility with any SiPM in the market, the ASIC is designed to be capable of accepting negative and positive polarity input signals. This 64-channel ASIC, is suitable for SiPM readout which requires high accuracy timing and charge measurements. Targeted applications would be PET prototyping with time-of-flight capability. Main features of Triroc includes high dynamic range ADC up to 2500 photoelectrons and TDC fine time binning of 40 ps. Triroc requires very minimal external components which means it is a good contender for compact multichannel PET prototyping. Triroc is designed by using AMS 0.35 μm SiGe technology and it was submitted in March 2014. The detail design of this chip will be presented.

  10. Apparent diffusion coefficient (ADC) does not correlate with different serological parameters in myositis and myopathy.

    Science.gov (United States)

    Meyer, Hans-Jonas; Ziemann, Oliver; Kornhuber, Malte; Emmer, Alexander; Quäschling, Ulf; Schob, Stefan; Surov, Alexey

    2018-06-01

    Background Magnetic resonance imaging (MRI) is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an imaging modality, which can reflect microstructural tissue composition. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules in tissue. Purpose To investigate ADC values in patients with myositis and non-inflammatory myopathy and to analyze possible associations between ADC and laboratory parameters in these patients. Material and Methods Overall, 17 patients with several myositis entities, eight patients with non-inflammatory myopathies, and nine patients without muscle disorder as a control group were included in the study (mean age = 55.3 ± 14.3 years). The diagnosis was confirmed by histopathology in every case. DWI was obtained in a 1.5-T scanner using two b-values: 0 and 1000 s/mm 2 . In all patients, the blood sample was acquired within three days to the MRI. The following serological parameters were estimated: C-reactive protein, lactate dehydrogenase, alanine aminotransferase, aspartate aminotransferase, creatine kinase, and myoglobine. Results The estimated mean ADC value for the myositis group was 1.89 ± 0.37 × 10 -3  mm 2 /s and for the non-inflammatory myopathy group was 1.79 ± 0.33 × 10 -3  mm 2 /s, respectively. The mean ADC values (1.15 ± 0.37 × 10 -3  mm 2 /s) were significantly higher to unaffected muscles (vs. myositis P = 0.0002 and vs. myopathy P = 0.0021). There were no significant correlations between serological parameters and ADC values. Conclusion Affected muscles showed statistically significantly higher ADC values than normal muscles. No linear correlations between ADC and serological parameters were identified.

  11. Implementation of integrated circuit and design of SAR ADC for fully implantable hearing aids.

    Science.gov (United States)

    Kim, Jong Hoon; Lee, Jyung Hyun; Cho, Jin-Ho

    2017-07-20

    The hearing impaired population has been increasing; many people suffer from hearing problems. To deal with this difficulty, various types of hearing aids are being rapidly developed. In particular, fully implantable hearing aids are being actively studied to improve the performance of existing hearing aids and to reduce the stigma of hearing loss patients. It has to be of small size and low-power consumption for easy implantation and long-term use. The objective of the study was to implement a small size and low-power consumption successive approximation register analog-to-digital converter (SAR ADC) for fully implantable hearing aids. The ADC was selected as the SAR ADC because its analog circuit components are less required by the feedback circuit of the SAR ADC than the sigma-delta ADC which is conventionally used in hearing aids, and it has advantages in the area and power consumption. So, the circuit of SAR ADC is designed considering the speech region of humans because the objective is to deliver the speech signals of humans to hearing loss patients. If the switch of sample and hold works in the on/off positions, the charge injection and clock feedthrough are produced by a parasitic capacitor. These problems affect the linearity of the hold voltage, and as a result, an error of the bit conversion is generated. In order to solve the problem, a CMOS switch that consists of NMOS and PMOS was used, and it reduces the charge injection because the charge carriers in the NMOS and PMOS have inversed polarity. So, 16 bit conversion is performed before the occurrence of the Least Significant Bit (LSB) error. In order to minimize the offset voltage and power consumption of the designed comparator, we designed a preamplifier with current mirror. Therefore, the power consumption was reduced by the power control switch used in the comparator. The layout of the designed SAR ADC was performed by Virtuoso Layout Editor (Cadence, USA). In the layout result, the size of the

  12. A low power 12-bit ADC for nuclear instrumentation

    International Nuclear Information System (INIS)

    Adachi, R.; Landis, D.; Madden, N.; Silver, E.; LeGros, M.

    1992-10-01

    A low power, successive approximation, analog-to-digital converter (ADC) for low rate, low cost, battery powered applications is described. The ADC is based on a commercial 50 mW successive approximation CMOS device (CS5102). An on-chip self-calibration circuit reduces the inherent differential nonlinearity to 7%. A further reduction of the differential nonlinearity to 0.5% is attained with a four bit Gatti function. The Gatti function is distributed to minimize battery power consumption. All analog functions reside with the ADC while the noisy digital functions reside in the personal computer based histogramming memory. Fiber optic cables carry afl digital information between the ADC and the personal computer based histogramming memory

  13. Role of Arginine decarboxylase (ADC) in Arabidopsis thaliana defence against the pathogenic bacterium Pseudomonas viridiflava.

    Science.gov (United States)

    Rossi, F R; Marina, M; Pieckenstain, F L

    2015-07-01

    Polyamine biosynthesis starts with putrescine production through the decarboxylation of arginine or ornithine. In Arabidopsis thaliana, putrescine is synthesised exclusively by arginine decarboxylase (ADC), which exists as two isoforms (ADC1 and 2) that are differentially regulated by abiotic stimuli, but their role in defence against pathogens has not been studied in depth. This work analysed the participation of ADC in Arabidopsis defence against Pseudomonas viridiflava. ADC activity and expression, polyamine levels and bacterial resistance were analysed in null mutants of each ADC isoform. In non-infected wild-type (WT) plants, ADC2 expression was much higher than ADC1. Analysis of adc mutants demonstrated that ADC2 contributes to a much higher extent than ADC1 to basal ADC activity and putrescine biosynthesis. In addition, adc2 mutants showed increased basal expression of salicylic acid- and jasmonic acid-dependent PR genes. Bacterial infection induced putrescine accumulation and ADC1 expression in WT plants, but pathogen-induced putrescine accumulation was blocked in adc1 mutants. Results suggest a specific participation of ADC1 in defence, although basal resistance was not decreased by dysfunction of either of the two ADC genes. In addition, and as opposed to WT plants, bacterial infection increased ADC2 expression and ADC activity in adc1 mutants, which could counterbalance the lack of ADC1. Results demonstrate a major contribution of ADC2 to total ADC activity and the specific induction of ADC1 in response to infection. A certain degree of functional redundancy between the two isoforms in relation to their contribution to basal resistance is also evident. © 2015 German Botanical Society and The Royal Botanical Society of the Netherlands.

  14. Time over threshold readout method of SiPM based small animal PET detector

    International Nuclear Information System (INIS)

    Valastyan, I.; Gal, J.; Hegyesi, G.; Kalinka, G.; Nagy, F.; Kiraly, B.; Imrek, J.; Molnar, J.

    2012-01-01

    Complete text of publication follows. The aim of the work was to design a readout concept for silicon photomultiplier (SiPM) sensor array used in small animal PET scanner. The detector module consist of LYSO 35x35 scintillation crystals, 324 SiPM sensors (arranged in 2x2 blocks and those quads in a 9x9 configuration) and FPGA based readout electronics. The dimensions of the SiPM matrix are area: 48x48 mm 2 and the size of one SiPM sensor is 1.95x2.2 mm 2 . Due to the high dark current of the SiPM, conventional Anger based readout method does not provide sufficient crystal position maps. Digitizing the 324 SiPM channels is a straightforward way to obtain proper crystal position maps. However handling hundreds of analogue input channels and the required DSP resources cause large racks of data acquisition electronics. Therefore coding of the readout channels is required. Proposed readout method: The coding of the 324 SiPMs consists two steps: Step 1) Reduction of the channels from 324 to 36: Row column readout, SiPMs are connected to each other in column by column and row-by row, thus the required channels are 36. The dark current of 18 connected SiPMs is small in off for identifying pulses coming from scintillating events. Step 2) Reduction of the 18 rows and columns to 4 channels: Comparators were connected to each rows and columns, and the level was set above the level of dark noise. Therefore only few comparators are active when scintillation light enters in the tile. The output of the comparator rows and columns are divided to two parts using resistor chains. Then the outputs of the resistor chains are digitized by a 4 channel ADC. However instead of the Anger method, time over threshold (ToT) was used. Figure 1 shows the readout concept of the SiPM matrix. In order to validate the new method and optimize the front-end electronics of the detector, the analogue signals were digitized before the comparators using a CAEN DT5740 32 channel digitizer, then the

  15. Increased tumour ADC value during chemotherapy predicts improved survival in unresectable pancreatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Nishiofuku, Hideyuki; Tanaka, Toshihiro; Kichikawa, Kimihiko [Nara Medical University, Department of Radiology and IVR Center, Kashihara-city, Nara (Japan); Marugami, Nagaaki [Nara Medical University, Department of Endoscopy and Ultrasound, Kashihara-city, Nara (Japan); Sho, Masayuki; Akahori, Takahiro; Nakajima, Yoshiyuki [Nara Medical University, Department of Surgery, Kashihara-city, Nara (Japan)

    2016-06-15

    To investigate whether changes to the apparent diffusion coefficient (ADC) of primary tumour in the early period after starting chemotherapy can predict progression-free survival (PFS) or overall survival (OS) in patients with unresectable pancreatic adenocarcinoma. Subjects comprised 43 patients with histologically confirmed unresectable pancreatic cancer treated with first-line chemotherapy. Minimum ADC values in primary tumour were measured using the selected area ADC (sADC), which excluded cystic and necrotic areas and vessels, and the whole tumour ADC (wADC), which included whole tumour components. Relative changes in ADC were calculated from baseline to 4 weeks after initiation of chemotherapy. Relationships between ADC and both PFS and OS were modelled by Cox proportional hazards regression. Median PFS and OS were 6.1 and 11.0 months, respectively. In multivariate analysis, sADC change was the strongest predictor of PFS (hazard ratio (HR), 4.5; 95 % confidence interval (CI), 1.7-11.9; p = 0.002). Multivariate Cox regression analysis for OS revealed sADC change and CRP as independent predictive markers, with sADC change as the strongest predictive biomarker (HR, 6.7; 95 % CI, 2.7-16.6; p = 0.001). Relative changes in sADC could provide a useful imaging biomarker to predict PFS and OS with chemotherapy for unresectable pancreatic adenocarcinoma. (orig.)

  16. Dedicated very front-end electronics for an ILC prototype hadronic calorimeter with SiPM read-out

    CERN Document Server

    de La Taille, C

    2008-01-01

    The SPIROC chip is a dedicated very front-end electronics for an ILC prototype hadronic calorimeter with Silicon photomultiplier (or MPPC) readout. This ASIC is due to equip a 10,000-channel demonstrator in 2009. SPIROC is an evolution of FLC_SiPM used for the ILC AHCAL physics prototype [1]. SPIROC was submitted in June 2007 and will be tested in September 2007. It embeds cutting edge features that fulfil ILC final detector requirements. It has been realized in 0.35m SiGe technology. It has been developed to match the requirements of large dynamic range, low noise, low consumption, high precision and large number of readout channels needed. SPIROC is an auto-triggered, bi-gain, 36-channel ASIC which allows to measure on each channel the charge from one photoelectron to 2000 and the time with a 100ps accurate TDC. An analogue memory array with a depth of 16 for each channel is used to store the time information and the charge measurement. A 12-bit Wilkinson ADC has been embedded to digitize the analogue memor...

  17. 55-mW, 1.2-V, 12-bit, 100-MSPS Pipeline ADCs for Wireless Receivers

    Science.gov (United States)

    Ito, Tomohiko; Kurose, Daisuke; Ueno, Takeshi; Yamaji, Takafumi; Itakura, Tetsuro

    For wireless receivers, low-power 1.2-V 12-bit 100-MSPS pipeline ADCs are fabricated in 90-nm CMOS technology. To achieve low-power dissipation at 1.2V without the degradation of SNR, the configuration of 2.5bit/stage is employed with an I/Q amplifier sharing technique. Furthermore, single-stage pseudo-differential amplifiers are used in a Sample-and-Hold (S/H) circuit and a 1st Multiplying Digital-to-Analog Converter (MDAC). The pseudo-differential amplifier with two-gain-stage transimpedance gain-boosting amplifiers realizes high DC gain of more than 90dB with low power. The measured SNR of the 100-MSPS ADC is 66.7dB at 1.2-V supply. Under that condition, each ADC dissipates only 55mW.

  18. Evaluation of silicon micro strip detectors with large read-out pitch

    International Nuclear Information System (INIS)

    Senyo, K.; Yamamura, K.; Tsuboyama, T.; Avrillon, S.; Asano, Y.; Bozek, A.; Natkaniec, Z.; Palka, H.; Rozanska, M.; Rybicki, K.

    1996-01-01

    For the development of the silicon micro-strip detector with the pitch of the readout strips as large as 250 μm on the ohmic side, we made samples with different structures. Charge collection was evaluated to optimize the width of implant strips, aluminum read-out strips, and/or the read-out scheme among strips. (orig.)

  19. The test ability of an adaptive pulse wave for ADC testing

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.

    2010-01-01

    In the conventional ADC production test method, a high-quality analogue sine wave is applied to the Analogue-to-Digital Converter (ADC), which is expensive to generate. Nowadays, an increasing number of ADCs are integrated into a system-on-chip (SoC) platform design, which usually contains a digital

  20. The clinical utility of reduced-distortion readout-segmented echo-planar imaging in the head and neck region: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Koyasu, Sho; Iima, Mami; Umeoka, Shigeaki; Morisawa, Nobuko; Togashi, Kaori [Kyoto University, Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Porter, David A. [Siemens AG, MED MR PLM AW Neurology, Allee am Roethelheimpark 2, Erlangen (Germany); Ito, Juichi [Kyoto University, Department of Otolaryngology, Head and Neck Surgery, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Le Bihan, Denis [Kyoto University, Human Brain Research Center, Graduate School of Medicine, Sakyo-Ku, Kyoto (Japan); Neurospin, CEA-Saclay Center, Gif-sur-Yvette Cedex (France)

    2014-12-15

    To evaluate whether readout-segmented echo-planar imaging (RS-EPI) diffusion weighted image (DWI) can diminish image distortion in the head and neck area, compared with single-shot (SS)-EPI DWI. We conducted phantom and patient studies using 3 T magnetic resonance imaging (MRI) with a 16-channel coil. For the phantom study, we evaluated distortion and signal homogeneity in gel phantoms. For the patient study, 29 consecutive patients with clinically suspicious parotid lesions were prospectively enrolled. RS-EPI and SS-EPI DWI were evaluated by two independent readers for identification of organ/lesion and distortion, using semiquantitative scales and quantitative scores. Apparent diffusion coefficient (ADC) values and contrast-noise ratios of parotid tumours (if present; n = 15) were also compared. The phantom experiments showed that RS-EPI provided less distorted and more homogeneous ADC maps than SS-EPI. In the patient study, RS-EPI was found to provide significantly less distortion in almost all organs/lesions (p < 0.05), according to both semiquantitative scales and quantitative scores. There was no significant difference in ADC values and contrast-noise ratios between the two DWI techniques. The distortion in DWI was significantly reduced with RS-EPI in both phantom and patient studies. The RS-EPI technique provided more homogenous images than SS-EPI, and can potentially offer higher image quality in the head and neck area. (orig.)

  1. Locally advanced rectal cancer: post-chemoradiotherapy ADC histogram analysis for predicting a complete response.

    Science.gov (United States)

    Cho, Seung Hyun; Kim, Gab Chul; Jang, Yun-Jin; Ryeom, Hunkyu; Kim, Hye Jung; Shin, Kyung-Min; Park, Jun Seok; Choi, Gyu-Seog; Kim, See Hyung

    2015-09-01

    The value of diffusion-weighted imaging (DWI) for reliable differentiation between pathologic complete response (pCR) and residual tumor is still unclear. Recently, a few studies reported that histogram analysis can be helpful to monitor the therapeutic response in various cancer research. To investigate whether post-chemoradiotherapy (CRT) apparent diffusion coefficient (ADC) histogram analysis can be helpful to predict a pCR in locally advanced rectal cancer (LARC). Fifty patients who underwent preoperative CRT followed by surgery were enrolled in this retrospective study, non-pCR (n = 41) and pCR (n = 9), respectively. ADC histogram analysis encompassing the whole tumor was performed on two post-CRT ADC600 and ADC1000 (b factors 0, 600 vs. 0, 1000 s/mm(2)) maps. Mean, minimum, maximum, SD, mode, 10th, 25th, 50th, 75th, 90th percentile ADCs, skewness, and kurtosis were derived. Diagnostic performance for predicting pCR was evaluated and compared. On both maps, 10th and 25th ADCs showed better diagnostic performance than that using mean ADC. Tenth percentile ADCs revealed the best diagnostic performance on both ADC600 (AZ 0.841, sensitivity 100%, specificity 70.7%) and ADC1000 (AZ 0.821, sensitivity 77.8%, specificity 87.8%) maps. In comparison between 10th percentile and mean ADC, the specificity was significantly improved on both ADC600 (70.7% vs. 53.7%; P = 0.031) and ADC1000 (87.8% vs. 73.2%; P = 0.039) maps. Post-CRT ADC histogram analysis is helpful for predicting pCR in LARC, especially, in improving the specificity, compared with mean ADC. © The Foundation Acta Radiologica 2014.

  2. Performance of CAMAC TDC and ADC in magnetic field

    International Nuclear Information System (INIS)

    Gupta, S.K.; Barbier, L.M.; Christian, E.R.; Geier, S.; Krizmanic, J.F.; Mitchell, J.W.; Streitmatter, R.E.; Wasilewski, P.J.

    1997-01-01

    The performance of a LeCroy CAMAC 2228A TDC and a 2249A ADC have been studied in presence of magnetic fields up to 5000 G. The conversion gains of the TDC and ADC increased with magnetic field in a non-linear fashion which can be adequately parameterized by a fourth-order polynomial. The behavior of both the TDC and ADC can be completely understood in terms of a change in the inductance of a ferromagnetic core inductor in the 20 MHz clock circuit of these units. (orig.)

  3. Comparison of performance of analog-to-digital converters (ADC) for pulse height analyzers

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Hirai, Shoji

    1981-01-01

    In the recent ADCs for pulse height analyzers (PHA), Wilkinson type is a leading one, and those with 50 to 200 MHz clock frequency and 8K channel are mostly on the market. The comparison of the performance of ADCs was conducted under the condition of using these multi-channel PHAs as γ-ray spectrometers. The following three ADCs were compared: ADC incorporated in CANBERRA 8100 MCA, and CANBERRA 8060 ADCs used as the ADCs for 1st and 2nd GAMA systems. In this case, the conversion gains of these ADCs were set at 4K because the memory of 8100 MCA was 4K, and the GAMA systems were also mostly operated at 4K. In this paper, report is made on the measurements of dead time, the change of γ peaks immediately after the power was turned on, the temperature dependence of ADCs the long term stability of ADCs, derivative non-linearity, and integration non-linearity. The dead time of the ADC of 8100 CMA was shorter in the range up to 1000 channels. The temperature dependence was -0.017%/deg C in 8100 MCA, and -0.061 and -0.072%/deg C in GAMA. The long term stability was -0.02%/14 hr in 8100 MCA, and -0.027%/14 hr in 8060 of 1st GAMA. The derivative non-linearity was 0.45% in 8100 MCA, 0.67% in 8060 of 1st GAMA, and the integration non-linearity was 0.075% for 8100 MCA, and 0.085 - 0.1% in 8060 ADCs. Also, the change of γ peaks immediately after the power was turned on for 8100 ADC was better than that of 8060 ADC. (Wakatsuki, Y.)

  4. Self-adapted sliding scale spectroscopy ADC

    International Nuclear Information System (INIS)

    Xu Qichun; Wang Jingjin

    1992-01-01

    The traditional sliding scale technique causes a disabled range that is equal to the sliding length, thus reduces the analysis range of a MCA. A method for reduce ADC's DNL, which is called self-adapted sliding scale method, has been designed and tested. With this method, the disabled range caused by a traditional sliding scale method can be eliminated by a random trial scale and there is no need of an additional amplitude discriminator with swing threshold. A special trial-and-correct logic is presented. The tested DNL of the spectroscopy ADC described here is less than 0.5%

  5. Can pretreatment ADC values predict recurrence of bladder cancer after transurethral resection?

    Energy Technology Data Exchange (ETDEWEB)

    Funatsu, Hiroyuki, E-mail: hirofunatsu999@hotmail.com [Division of Diagnostic Imaging, Chiba Cancer Center, 666-2 Nitona-cho, Chuo-ku, Chiba 260-8717 (Japan); Imamura, Akihiro; Takano, Hideyuki [Division of Diagnostic Imaging, Chiba Cancer Center, 666-2 Nitona-cho, Chuo-ku, Chiba 260-8717 (Japan); Ueda, Takeshi [Division of Urology, Chiba Cancer Center, 666-2 Nitona-cho, Chuo-ku, Chiba 260-8717 (Japan); Uno, Takashi [Department of Radiology, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuou-ku, Chiba 260-8670 (Japan)

    2012-11-15

    Objective: The aim of this retrospective study was to investigate the association between the pretreatment apparent diffusion coefficient (ADC) value and recurrence of bladder cancer after transurethral resection. Methods: Patients with superficial bladder cancer were identified. Mean ADC values of the tumors were compared between patients with and without recurrence following trans-urethral resection. A receiver-operator characteristic curve was used for determining the optimal cutoff ADC value. Univariate and multivariate analyses were used to determine the effect of ADC values and other factors. Results: With a mean follow-up period of 25 months, bladder cancer recurred in 14 of 44 patients (32%). The mean ADC value of tumors in patients with recurrence was lower than in those without recurrence (1.08 mm{sup 2}/s vs. 1.28 Multiplication-Sign 10{sup -3} mm{sup 2}/s; p = 0.003). The optimal cutoff ADC value for predicting recurrence was determined to be 1.12 Multiplication-Sign 10{sup -3} mm{sup 2}/s. A modest and significant negative correlation was observed between the ADC values and tumor size (r = -0.436, p = 0.008). After adjustment for size and risk groups, an ADC value equal to or less than the optimal cutoff remained a significant predictor of recurrence (odds ratio 6.3, 95% CI 1.23-32.2, p = 0.027). Conclusion: Pretreatment ADC values may be an independent predictor of bladder cancer recurrence.

  6. Can pretreatment ADC values predict recurrence of bladder cancer after transurethral resection?

    International Nuclear Information System (INIS)

    Funatsu, Hiroyuki; Imamura, Akihiro; Takano, Hideyuki; Ueda, Takeshi; Uno, Takashi

    2012-01-01

    Objective: The aim of this retrospective study was to investigate the association between the pretreatment apparent diffusion coefficient (ADC) value and recurrence of bladder cancer after transurethral resection. Methods: Patients with superficial bladder cancer were identified. Mean ADC values of the tumors were compared between patients with and without recurrence following trans-urethral resection. A receiver–operator characteristic curve was used for determining the optimal cutoff ADC value. Univariate and multivariate analyses were used to determine the effect of ADC values and other factors. Results: With a mean follow-up period of 25 months, bladder cancer recurred in 14 of 44 patients (32%). The mean ADC value of tumors in patients with recurrence was lower than in those without recurrence (1.08 mm 2 /s vs. 1.28 × 10 −3 mm 2 /s; p = 0.003). The optimal cutoff ADC value for predicting recurrence was determined to be 1.12 × 10 −3 mm 2 /s. A modest and significant negative correlation was observed between the ADC values and tumor size (r = −0.436, p = 0.008). After adjustment for size and risk groups, an ADC value equal to or less than the optimal cutoff remained a significant predictor of recurrence (odds ratio 6.3, 95% CI 1.23–32.2, p = 0.027). Conclusion: Pretreatment ADC values may be an independent predictor of bladder cancer recurrence.

  7. Digitally assisted pipeline ADCs theory and implementation

    CERN Document Server

    Murmann, Boris

    2007-01-01

    List of Figures. List of Tables. Acknowledgements. Preface. 1: Introduction. 1. Motivation. 2. Overview. 3. Chapter Organization. 2: Performance Trends. 1. Introduction. 2. Digital Performance Trends. 3. ADC Performance Trends. 3: Scaling Analysis. 1. Introduction. 2. Basic Device Scaling from a Digital Perspective. 3. Technology Metrics for Analog Circuits. 4. Scaling Impact on Matching-Limited Circuits. 5. Scaling Impact on Noise-Limited Circuits. 4: Improving Analog Circuit Efficiency. 1. Introduction. 2. Analog Circuit Challenges. 3. The Cost of Feedback. 4. Two-Stage Feedback Amplifier vs. Open-Loop Gain Stage. 5. Discussion. 5: Open-Loop Pipelined ADCs. 1. A Brief Review of Pipelined ADCs. 2. Conventional Stage Implementation. 3. Open-Loop Pipeline Stages. 4. Alternative Transconductor Implementations. 6: Digital Nonlinearity Correction. 1. Overview. 2. Error Model and Digital Correction. 3. Alternative Error Models. 7: Statistics-Based Parameter Estimation. 1. Introduction. 2. Modulation Approach. 3. R...

  8. The use of MRI apparent diffusion coefficient (ADC) in monitoring the development of brain infarction

    International Nuclear Information System (INIS)

    Shen, Jian-Min; Xia, Xian-Wu; Kang, Wu-Gen; Yuan, Jian-Jun; Sheng, Liang

    2011-01-01

    To study the rules that apparent diffusion coefficient (ADC) changes with time and space in cerebral infarction, and to provide the evidence in defining the infarction stages. 117 work-ups in 98 patients with cerebral infarction (12 hyperacute, 43 acute, 29 subacute, 10 steady, and 23 chronic infarctions) were imaged with both conventional MRI and diffusion weighted imaging. The average ADC values, the relative ADC (rADC) values, and the ADC values or rADC values from the center to the periphery of the lesion were calculated. The average ADC values and the rADC values of hyperacute and acute infarction lesion depressed obviously. rADC values in hyperacute and acute stage was minimized, and increased progressively as time passed and appeared as 'pseudonormal' values in approximately 8 to 14 days. Thereafter, rADC values became greater than normal in chronic stage. There was positive correlation between rADC values and time (P < 0.01). The ADC values and the rADC values in hyperacute and acute lesions had gradient signs that these lesions increased from the center to the periphery. The ADC values and the rADC values in subacute lesions had adverse gradient signs that these lesions decreased from the center to the periphery. The ADC values of infarction lesions have evolution rules with time and space. The evolution rules with time and those in space can be helpful to decide the clinical stage, and to provide the evidence in guiding the treatment or judging the prognosis in infarction

  9. A 12bits 40MSPS SAR ADC with a redundancy algorithm and digital calibration for the ATLAS LAr calorimeter readout

    CERN Document Server

    Zeloufi, Mohamed; The ATLAS collaboration; Rarbi, Fatah-ellah

    2015-01-01

    We present a SAR ADC with a generalized redundant search algorithm offering the flexibility to relax the requirements on the DAC settling time. The redundancy allows also a digital background calibration, based on a code density analysis, to compensate the capacitors mismatching effects. The total of capacitors used in this architecture is limited to a half of the one in a classical SAR design. Only 2^11 unit capacitors were necessary to reach 12bits resolution, and the switching algorithm is intrinsically monotonic. The design is fully differential featuring 12-bit 40MS/s in a CMOS 130nm 1P8M process.

  10. A Radiation Hardened by Design CMOS ASIC for Thermopile Readouts

    Science.gov (United States)

    Quilligan, G.; Aslam, S.; DuMonthier, J.

    2012-01-01

    A radiation hardened by design (RHBD) mixed-signal application specific integrated circuit (ASIC) has been designed for a thermopile readout for operation in the harsh Jovian orbital environment. The multi-channel digitizer (MCD) ASIC includes 18 low noise amplifier channels which have tunable gain/filtering coefficients, a 16-bit sigma-delta analog-digital converter (SDADC) and an on-chip controller. The 18 channels, SDADC and controller were designed to operate with immunity to single event latchup (SEL) and to at least 10 Mrad total ionizing dose (TID). The ASIC also contains a radiation tolerant 16-bit 20 MHz Nyquist ADC for general purpose instrumentation digitizer needs. The ASIC is currently undergoing fabrication in a commercial 180 nm CMOS process. Although this ASIC was designed specifically for the harsh radiation environment of the NASA led JEO mission it is suitable for integration into instrumentation payloads 011 the ESA JUICE mission where the radiation hardness requirements are slightly less stringent.

  11. Experimental characterization of the 192 channel Clear-PEM frontend ASIC coupled to a multi-pixel APD readout of LYSO:Ce crystals

    International Nuclear Information System (INIS)

    Albuquerque, Edgar; Bexiga, Vasco; Bugalho, Ricardo; Carrico, Bruno; Ferreira, Claudia S.; Ferreira, Miguel; Godinho, Joaquim; Goncalves, Fernando; Leong, Carlos; Lousa, Pedro; Machado, Pedro; Moura, Rui; Neves, Pedro; Ortigao, Catarina; Piedade, Fernando; Pinheiro, Joao F.; Rego, Joel; Rivetti, Angelo; Rodrigues, Pedro; Silva, Jose C.

    2009-01-01

    In the framework of the Clear-PEM project for the construction of a high-resolution scanner for breast cancer imaging, a very compact and dense frontend electronics system has been developed for readout of multi-pixel S8550 Hamamatsu APDs. The frontend electronics are instrumented with a mixed-signal Application-Specific Integrated Circuit (ASIC), which incorporates 192 low-noise charge pre-amplifiers, shapers, analog memory cells and digital control blocks. Pulses are continuously stored in memory cells at clock frequency. Channels above a common threshold voltage are readout for digitization by off-chip free-sampling ADCs. The ASIC has a size of 7.3x9.8mm 2 and was implemented in a AMS 0.35μm CMOS technology. In this paper the experimental characterization of the Clear-PEM frontend ASIC, reading out multi-pixel APDs coupled to LYSO:Ce crystal matrices, is presented. The chips were mounted on a custom test board connected to six APD arrays and to the data acquisition system. Six 32-pixel LYSO:Ce crystal matrices coupled on both sides to APD arrays were readout by two test boards. All 384 channels were operational. The chip power consumption is 660 mW (3.4 mW per channel). A very stable behavior of the chip was observed, with an estimated ENC of 1200-1300e - at APD gain 100. The inter-channel noise dispersion and mean baseline variation is less than 8% and 0.5%, respectively. The spread in the gain between different channels is found to be 1.5%. Energy resolution of 16.5% at 511 keV and 12.8% at 662 keV has been measured. Timing measurements between the two APDs that readout the same crystal is extracted and compared with detailed Monte Carlo simulations. At 511 keV the measured single photon time RMS resolution is 1.30 ns, in very good agreement with the expected value of 1.34 ns.

  12. A low-power and small-area column-level ADC for high frame-rate CMOS pixel sensor

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, L., E-mail: liang.zhang@iphc.cnrs.fr [School of Physics, Key Laboratory of Particle Physics and Particle Irradiation, Shandong University, 250100 Jinan (China); Institut Pluridisciplinaire Hubert Curien, University of Strasbourg, CNRS/IN2P3/UDS, 23 rue du loess, BP 28, 67037 Strasbourg (France); Morel, F.; Hu-Guo, C.; Hu, Y. [Institut Pluridisciplinaire Hubert Curien, University of Strasbourg, CNRS/IN2P3/UDS, 23 rue du loess, BP 28, 67037 Strasbourg (France)

    2014-07-01

    CMOS pixel sensors (CPS) have demonstrated performances meeting the specifications of the International Linear Collider (ILC) vertex detector (VTX). This paper presents a low-power and small-area 4-bit column-level analog-to-digital converter (ADC) for CMOS pixel sensors. The ADC employs a self-timed trigger and completes the conversion by performing a multi-bit/step approximation. As in the outer layers of the ILC vertex detector hit density is of the order of a few per thousand, in order to reduce power consumption, the ADC is designed to work in two modes: active mode and idle mode. The ADC is fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. It is implemented with 48 columns in a sensor prototype. Each column ADC covers an area of 35 ×545 μm{sup 2}. The measured temporal noise and Fixed Pattern Noise (FPN) are 0.96 mV and 0.40 mV, respectively. The power consumption, for a 3 V supply and 6.25 MS/s sampling rate, is 486 μW during idle time, which is by far the most frequently employed one. This value rises to 714 μW in the case of the active mode. The measured differential nonlinearity (DNL) and integral nonlinearity (INL) are 0.49/−0.28 LSB and 0.29/−0.20 LSB, respectively. - Highlights: • CMOS sensor integrated with column-level ADC is proposed for ILC VTX outer layers. • A low-power and small-area column-level ADC for high frame-rate CPS is presented. • The test results demonstrate the power and area efficiency. • The architecture is suitable for the outer layer CMOS sensors.

  13. A low-power and small-area column-level ADC for high frame-rate CMOS pixel sensor

    International Nuclear Information System (INIS)

    Zhang, L.; Morel, F.; Hu-Guo, C.; Hu, Y.

    2014-01-01

    CMOS pixel sensors (CPS) have demonstrated performances meeting the specifications of the International Linear Collider (ILC) vertex detector (VTX). This paper presents a low-power and small-area 4-bit column-level analog-to-digital converter (ADC) for CMOS pixel sensors. The ADC employs a self-timed trigger and completes the conversion by performing a multi-bit/step approximation. As in the outer layers of the ILC vertex detector hit density is of the order of a few per thousand, in order to reduce power consumption, the ADC is designed to work in two modes: active mode and idle mode. The ADC is fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. It is implemented with 48 columns in a sensor prototype. Each column ADC covers an area of 35 ×545 μm 2 . The measured temporal noise and Fixed Pattern Noise (FPN) are 0.96 mV and 0.40 mV, respectively. The power consumption, for a 3 V supply and 6.25 MS/s sampling rate, is 486 μW during idle time, which is by far the most frequently employed one. This value rises to 714 μW in the case of the active mode. The measured differential nonlinearity (DNL) and integral nonlinearity (INL) are 0.49/−0.28 LSB and 0.29/−0.20 LSB, respectively. - Highlights: • CMOS sensor integrated with column-level ADC is proposed for ILC VTX outer layers. • A low-power and small-area column-level ADC for high frame-rate CPS is presented. • The test results demonstrate the power and area efficiency. • The architecture is suitable for the outer layer CMOS sensors

  14. High power-efficient asynchronous SAR ADC for IoT devices

    Science.gov (United States)

    Zhang, Beichen; Yao, Bingbing; Liu, Liyuan; Liu, Jian; Wu, Nanjian

    2017-10-01

    This paper presents a power-efficient 100-MS/s, 10-bit asynchronous successive approximation register (SAR) ADC. It includes an on-chip reference buffer and the total power dissipation is 6.8 mW. To achieve high performance with high power-efficiency in the proposed ADC, bootstrapped switch, redundancy, set-and-down switching approach, dynamic comparator and dynamic logic techniques are employed. The prototype was fabricated using 65 nm standard CMOS technology. At a 1.2-V supply and 100 MS/s, the ADC achieves an SNDR of 56.2 dB and a SFDR of 65.1 dB. The ADC core consumes only 3.1 mW, resulting in a figure of merit (FOM) of 30.27 fJ/conversionstep and occupies an active area of only 0.009 mm2.

  15. The use of MRI apparent diffusion coefficient (ADC in monitoring the development of brain infarction

    Directory of Open Access Journals (Sweden)

    Yuan Jian-Jun

    2011-01-01

    Full Text Available Abstract Background To study the rules that apparent diffusion coefficient (ADC changes with time and space in cerebral infarction, and to provide the evidence in defining the infarction stages. Methods 117 work-ups in 98 patients with cerebral infarction (12 hyperacute, 43 acute, 29 subacute, 10 steady, and 23 chronic infarctions were imaged with both conventional MRI and diffusion weighted imaging. The average ADC values, the relative ADC (rADC values, and the ADC values or rADC values from the center to the periphery of the lesion were calculated. Results The average ADC values and the rADC values of hyperacute and acute infarction lesion depressed obviously. rADC values in hyperacute and acute stage was minimized, and increased progressively as time passed and appeared as "pseudonormal" values in approximately 8 to 14 days. Thereafter, rADC values became greater than normal in chronic stage. There was positive correlation between rADC values and time (P Conclusion The ADC values of infarction lesions have evolution rules with time and space. The evolution rules with time and those in space can be helpful to decide the clinical stage, and to provide the evidence in guiding the treatment or judging the prognosis in infarction.

  16. Power and area efficient 4-bit column-level ADC in a CMOS pixel sensor for the ILD vertex detector

    International Nuclear Information System (INIS)

    Zhang, L; Morel, F; Hu-Guo, Ch; Hu, Y

    2013-01-01

    A 48 × 64 pixels prototype CMOS pixel sensor (CPS) integrated with 4-bit column-level, self triggered ADCs for the outer layers of the ILD vertex detector (VTX) was developed and fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. The pixel concept combines in-pixel amplification with a correlated double sampling (CDS) operation. The ADCs accommodating the pixel read out in a rolling shutter mode complete the conversion by performing a multi-bit/step approximation. The design was optimised for power saving at sampling frequency. The prototype sensor is currently at the stage of being started testing and evaluation. So what is described is based on post simulation results rather than test data. This 4-bit ADC dissipates, at a 3-V supply and 6.25-MS/s sampling rate, 486 μW in its inactive mode, which is by far the most frequent. This value rises to 714 μW in case of the active mode. Its footprint amounts to 35 × 545 μm 2 .

  17. An intelligent readout controller for Fastbus, the Fermilab FSCC

    International Nuclear Information System (INIS)

    Bowden, M.; Kwarciany, R.; Urish, J.

    1990-01-01

    This paper reports on the Fermilab FASTBUS Smart Crate Controller which is intended as a fast, versatile, and cost effective solution for the readout of FASTBUS crates. The on-board 68020 provides intelligence and a programmable microsequencer controls the main readout path. The FSCC supports communication via serial RS 232, Ethernet, and FASTBUS. The main readout path may be programmed for a variety of protocols. Currently, RS 422, VDAS, ECL line, and fiber-optic interfaces are being developed. Hardware interfacing is via the FASTBUS auxiliary connector using a personality card. Provision is made for some on-board formatting and processing of data. The 68020 may sample the data, also headers and word counts may be inserted into the data stream. Data is buffered by FIFOs to allow asynchronous readout

  18. Low Power Continuous-Time Delta-Sigma ADC with Current Output DAC

    DEFF Research Database (Denmark)

    Marker-Villumsen, Niels; Jørgensen, Ivan Harald Holger; Bruun, Erik

    2015-01-01

    The paper presents a continuous-time (CT) DeltaSigma (∆Σ) analog-to-digital converter (ADC) using a current output digital-to-analog converter (DAC) for the feedback. From circuit analysis it is shown that using a current output DAC makes it possible to relax the noise requirements of the 1st...... integrator of the loopfilter, and thereby reduce the current consumption. Furthermore, the noise of the current output DAC being dependent on the ADC input signal level, enabling a dynamic range that is larger than the peak signal-to-noise ratio (SNR). The current output DAC is used in a 3rd order multibit...... CT ∆Σ ADC for audio applications, designed in a 0.18 µm CMOS process, with active-RC integrators, a 7-level Flash ADC quantizer and current output DAC for the feedback. From simulations the ADC achieves a dynamic range of 95.0 dB in the audio band, with a current consumption of 284 µA for a 1.7 V...

  19. Normal cranial bone marrow MR imaging pattern with age-related ADC value distribution

    International Nuclear Information System (INIS)

    Li Qi; Pan Shinong; Yin Yuming; Li Wei; Chen Zhian; Liu Yunhui; Wu Zhenhua; Guo Qiyong

    2011-01-01

    Objective: To determine MRI appearances of normal age-related cranial bone marrow and the relationship between MRI patterns and apparent diffusion coefficient (ADC) values. Methods: Five hundred subjects were divided into seven groups based on ages. Cranial bone marrow MRI patterns were performed based on different thickness of the diploe and signal intensity distribution characteristics. ADC values of the frontal, parietal, occipital and temporal bones on DWI were measured and calculated. Correlations between ages and ADC values, between patterns and ADC values, as well as the distribution of ADC values were analyzed. Results: Normal cranial bone marrow was divided into four types and six subtypes, Type I, II, III and IV, which had positive correlation with age increasing (χ 2 = 266.36, P 0.05). In addition, there was significant negative correlation between the ADC values and MRI patterns in the normal parietal and occipital bones (r = -0.691 and -0.750, P < 0.01). Conclusion: The combination of MRI features and ADC values changes in different cranial bones showed significant correlation with age increasing. Familiar with the MRI appearance of the normal bone marrow conversion pattern in different age group and their ADC value will aid the diagnosis and differential of the cranial bone pathology.

  20. CUSTOMER PERCEPTION ON ALTERNATIVE DELIVERY CHANNEL (ADC OF BANKS IN BANGLADESH

    Directory of Open Access Journals (Sweden)

    Shahed BIN SADIQUE

    2016-12-01

    Full Text Available This paper aims at understanding the level of customer’s perception on alternative delivery channel of different commercial schedule banks of Bangladesh. Considering the significant development in technology and for sustainability, banking industry in Bangladesh has expanded banking operation through offering different ADCs to attract customers which are ultimately changing the perception of customers in the long run. Based on this reality, data were collected from a survey and a usable sample of 134 was taken for analysis. KAPPA test and multiple regression model is used to analyze the overall consistency of respondent’s responses and measurement of consumers’ perception. The results of the survey show that visibility, availability, self-security, confidential transaction ability, easiness and simplicity in the procedure of ADC makes it more attractive to consumer. The findings also suggest that security of physical establishment of ADC is vital though banks have given less importance to it. From the study, it is found that in order to change perception and to attract more users to banking; it is not going to be enough to make the system easy to interact with. Banks should develop more secured and private alternative delivery channels that will be reliable to their customers. Thus, management attention might be effectively focused on the development of such sectors that have been properly identified in this research.

  1. Customer Perception on Alternative Delivery Channel (ADC of Banks in Bangladesh

    Directory of Open Access Journals (Sweden)

    Shahed BIN SADIQUE

    2016-12-01

    Full Text Available This paper aims at understanding the level of customer’s perception on alternative delivery channel of different commercial schedule banks of Bangladesh. Considering the significant development in technology and for sustainability, banking industry in Bangladesh has expanded banking operation through offering different ADCs to attract customers which are ultimately changing the perception of customers in the long run. Based on this reality, data were collected from a survey and a usable sample of 134 was taken for analysis. KAPPA test and multiple regression model is used to analyze the overall consistency of respondent’s responses and measurement of consumers’ perception. The results of the survey show that visibility, availability, self-security, confidential transaction ability, easiness and simplicity in the procedure of ADC makes it more attractive to consumer. The findings also suggest that security of physical establishment of ADC is vital though banks have given less importance to it. From the study, it is found that in order to change perception and to attract more users to banking; it is not going to be enough to make the system easy to interact with. Banks should develop more secured and private alternative delivery channels that will be reliable to their customers. Thus, management attention might be effectively focused on the development of such sectors that have been properly identified in this research.

  2. D0 calorimeter electronics

    International Nuclear Information System (INIS)

    Schamberger, R.D.

    1991-01-01

    A detailed description of the electronics used to readout the signals from the D0 Uranium-Liquid Argon Calorimeter is presented. The three major components of the readout system are the charge sensitive preamps, the shaping and sample and hold circuits, and the Analog to Digital converters. The very low noise preamps achieve an input noise equivalent to 2000e's + 3000e's per nanofarad of input capacitance. The coherent noise in the system is very low, less than 1/20 of an ADC count which is equivalent to about 200 KeV of energy incident on the detector. The ADC system contains a 12 bit, 5 μsecond successive approximation digitizer. We maintain a 15 bit dynamic range by automatically amplifying small signals after they are held, but before digitization. The ADC also contains pedestal and limit memory, to allow (on a channel by channel basis) offset subtraction, and suppression of small signals, symmetrically around zero signal. (orig.)

  3. Semi-autonomous controller for data acquisition, the Brilliant ADC

    International Nuclear Information System (INIS)

    Breidenbach, M.; Frank, E.; Hall, J.; Nelson, D.

    1977-10-01

    A set of high speed 16-bit computers and ADC's designed and built for the data collection, compression, and correction system of the SLAC/LBL Mark II Magnetic Detector. The ''Brilliant ADC'' controls the analog multiplexing of a CAMAC crate of data acquisition modules, digitizes the analog data, and executes microprogrammed algorithms for data handling and correction

  4. Normalization of ADC does not improve correlation with overall survival in patients with high-grade glioma (HGG).

    Science.gov (United States)

    Qin, Lei; Li, Angie; Qu, Jinrong; Reinshagen, Katherine; Li, Xiang; Cheng, Su-Chun; Bryant, Annie; Young, Geoffrey S

    2018-04-01

    Mixed reports leave uncertainty about whether normalization of apparent diffusion coefficient (ADC) to a within-subject white matter reference is necessary for assessment of tumor cellularity. We tested whether normalization improves the previously reported correlation of resection margin ADC with 15-month overall survival (OS) in HGG patients. Spin-echo echo-planar DWI was retrieved from 3 T MRI acquired between maximal resection and radiation in 37 adults with new-onset HGG (25 glioblastoma; 12 anaplastic astrocytoma). ADC maps were produced with the FSL DTIFIT tool (Oxford Centre for Functional MRI). 3 neuroradiologists manually selected regions of interest (ROI) in normal appearing white matter (NAWM) and in non-enhancing tumor (NT) Normalized ADC (nADC) was computed as the ratio of absolute NT ADC to NAWM ADC. Reproducibility of nADC and absolute ADC among the readers' ROI was assessed using intra-class correlation coefficient (ICC) and within-subject coefficient of variation (wCV). Correlations of ADC and nADC with OS were compared using receiver operating characteristics (ROC) analysis. A p value 0.05 was considered statistically significant. Both mean ADC and nADC differed significantly between patients subgrouped by 15-month OS (p = 0.0014 and 0.0073 respectively). wCV and ICC among the readers were similar for absolute and normalized ADC. In ROC analysis of correlation with OS, nADC did not perform significantly better than absolute ADC. Normalization does not significantly improve the correlation of absolute ADC with OS in HGG, suggesting that normalization is not necessary for clinical or research ADC analysis in HGG patients.

  5. Sub-10ps monolithic and low-power photodetector readout

    International Nuclear Information System (INIS)

    Varner, Gary S.; Ruckman, Larry L.

    2009-01-01

    Recent advances in photon detectors have resulted in high-density imaging arrays that offer many performance and cost advantages. In particular, the excellent transit time spread of certain devices show promise to provide tangible benefits in applications such as Positron Emission Tomography (PET). Meanwhile, high-density, high-performance readout techniques have not kept on pace for exploiting these developments. Photodetector readout for next generation high event rate particle identification and time-resolved PET requires a highly-integrated, low-power, and cost-effective readout technique. We propose fast waveform sampling as a method that meets these criteria and demonstrate that sub-10ps resolution can be obtained for an existing device

  6. Sub-10ps monolithic and low-power photodetector readout

    Energy Technology Data Exchange (ETDEWEB)

    Varner, Gary S.; Ruckman, Larry L.

    2009-02-20

    Recent advances in photon detectors have resulted in high-density imaging arrays that offer many performance and cost advantages. In particular, the excellent transit time spread of certain devices show promise to provide tangible benefits in applications such as Positron Emission Tomography (PET). Meanwhile, high-density, high-performance readout techniques have not kept on pace for exploiting these developments. Photodetector readout for next generation high event rate particle identification and time-resolved PET requires a highly-integrated, low-power, and cost-effective readout technique. We propose fast waveform sampling as a method that meets these criteria and demonstrate that sub-10ps resolution can be obtained for an existing device.

  7. Brookhaven FASTBUS ADC's

    International Nuclear Information System (INIS)

    Schmidt, M.P.; Black, J.K.; Blatt, S.R.

    1983-01-01

    A high energy physics experiment has been performed at Brookhaven National Laboratory on k/sub L/ 0 → 2π 0 decays employing a large (> 200 element) lead glass array as an electromagnetic calorimeter. To acquire pulse height information from the detector we have constructed ADC modules in the context of the Brookhaven Fastbus data acquisition system. Digitization (8 bits) and encoding, including pedestal subtraction and data sparsing, is achieved for each 16 channel module in 6 μsec

  8. A robust and simple two-mode digital calibration technique for pipelined ADC

    Energy Technology Data Exchange (ETDEWEB)

    Yin Xiumei; Zhao Nan; Sekedi Bomeh Kobenge; Yang Huazhong, E-mail: yxm@mails.tsinghua.edu.cn [Department of Electronic Engineering, Tsinghua University, Beijing 100084 (China)

    2011-03-15

    This paper presents a two-mode digital calibration technique for pipelined analog-to-digital converters (ADC). The proposed calibration eliminates the errors of residual difference voltage induced by capacitor mismatch of pseudorandom (PN) sequence injection capacitors at the ADC initialization, while applies digital background calibration to continuously compensate the interstage gain errors in ADC normal operation. The presented technique not only reduces the complexity of analog circuit by eliminating the implementation of PN sequence with accurate amplitude in analog domain, but also improves the performance of digital background calibration by minimizing the sensitivity of calibration accuracy to sub-ADC errors. The use of opamps with low DC gains in normal operation makes the proposed design more compatible with future nanometer CMOS technology. The prototype of a 12-bit 40-MS/s pipelined ADC with the two-mode digital calibration is implemented in 0.18-{mu}m CMOS process. Adopting a simple telescopic opamp with a DC gain of 58-dB in the first stage, the measured SFDR and SNDR within the first Nyquist zone reach 80-dB and 66-dB, respectively. With the calibration, the maximum integral nonlinearity (INL) of the ADC reduces from 4.75-LSB to 0.65-LSB, while the ADC core consumes 82-mW at 3.3-V power supply. (semiconductor integrated circuits)

  9. Readout Architecture for Hybrid Pixel Readout Chips

    CERN Document Server

    AUTHOR|(SzGeCERN)694170; Westerlund, Tomi; Wyllie, Ken

    The original contribution of this thesis to knowledge are novel digital readout architectures for hybrid pixel readout chips. The thesis presents asynchronous bus-based architecture, a data-node based column architecture and a network-based pixel matrix architecture for data transportation. It is shown that the data-node architecture achieves readout efficiency 99 % with half the output rate as a bus-based system. The network-based solution avoids ``broken'' columns due to some manufacturing errors, and it distributes internal data traffic more evenly across the pixel matrix than column-based architectures. An improvement of $>$ 10 % to the efficiency is achieved with uniform and non-uniform hit occupancies. Architectural design has been done using transaction level modeling ($TLM$) and sequential high-level design techniques for reducing the design and simulation time. It has been possible to simulate tens of column and full chip architectures using the high-level techniques. A decrease of $>$ 10 in run-time...

  10. A Contribution to Nyquist-Rate ADC Modeling - Detailed Algorithm Description

    Directory of Open Access Journals (Sweden)

    J. Zidek

    2012-04-01

    Full Text Available In this article, the innovative ADC modeling algorithm is described. It is well suitable for nyquist-rate ADC error back annotation. This algorithm is the next step of building a support tool for IC design engineers. The inspiration for us was the work [2]. Here, the ADC behavior is divided into HCF (High Code Frequency and LCF (Low Code Frequency separated independent parts. This paper is based on the same concept but the model coefficients are estimated in a different way only from INL data. The HCF order recognition part was newly added as well. Thanks to that the HCF coefficients number is lower in comparison with the original Grimaldi’s work (especially for converters with low ratio between HCF and “random” part of INL. Modeling results are demonstrated on a real data set measured by ASICentrum on chargeredistribution type SAR ADC chip. Results are showed not only by coefficient values but also by the Model Coverage metrics. Model limitations are also discussed.

  11. New Approach Based on Compressive Sampling for Sample Rate Enhancement in DASs for Low-Cost Sensing Nodes

    Directory of Open Access Journals (Sweden)

    Francesco Bonavolontà

    2014-10-01

    Full Text Available The paper deals with the problem of improving the maximum sample rate of analog-to-digital converters (ADCs included in low cost wireless sensing nodes. To this aim, the authors propose an efficient acquisition strategy based on the combined use of high-resolution time-basis and compressive sampling. In particular, the high-resolution time-basis is adopted to provide a proper sequence of random sampling instants, and a suitable software procedure, based on compressive sampling approach, is exploited to reconstruct the signal of interest from the acquired samples. Thanks to the proposed strategy, the effective sample rate of the reconstructed signal can be as high as the frequency of the considered time-basis, thus significantly improving the inherent ADC sample rate. Several tests are carried out in simulated and real conditions to assess the performance of the proposed acquisition strategy in terms of reconstruction error. In particular, the results obtained in experimental tests with ADC included in actual 8- and 32-bits microcontrollers highlight the possibility of achieving effective sample rate up to 50 times higher than that of the original ADC sample rate.

  12. Endometrial cancer: correlation of apparent diffusion coefficient (ADC) with tumor cellularity and tumor grade.

    Science.gov (United States)

    Kishimoto, Keiko; Tajima, Shinya; Maeda, Ichiro; Takagi, Masayuki; Ueno, Takahiko; Suzuki, Nao; Nakajima, Yasuo

    2016-08-01

    Diffusion-weighted imaging (DWI) and the apparent diffusion coefficient (ADC) are widely used for detecting uterine endometrial cancer. The relationships between ADC values and pathological features of endometrial cancer have not yet been established. To investigate whether ADC values of endometrial cancer vary according to histologic tumor cellularity and tumor grade. We retrospectively reviewed 30 pathologically confirmed endometrial cancers. All patients underwent conventional non-enhanced magnetic resonance imaging (MRI) and DWI procedures, and ADC values were calculated. Tumor cellularity was evaluated by counting cancer cells in three high-power ( × 400) fields. The correlation between ADC values and tumor cellularity was assessed using Pearson's correlation coefficient test for statistical analysis. The mean ± standard deviation (SD) ADC value ( ×10(-3) mm(2)/s) of endometrial cancer was 0.85 ± 0.22 (range, 0.55-1.71). The mean ± SD tumor cellularity was 528.36 ± 16.89 (range, 298.0-763.6). ADC values were significantly inversely correlated with tumor cellularity. No significant relationship was observed between ADC values and tumor grade (mean ADC values: G1, 0.88 ± 0.265 × 10(-3) mm(2)/s; G2, 0.80 ± 0.178 × 10(-3) mm(2)/s; G3, 0.81 ± 0.117 × 10(-3) mm(2)/s). There is a significant inverse relationship between ADC values and tumor cellularity in endometrial cancer. No significant differences in average ADC value were observed between G1, G2, and G3 tumors. However, the lower the tumor grade, the wider the SD. © The Foundation Acta Radiologica 2015.

  13. Timing and Readout Contorl in the LHCb Upgraded Readout System

    CERN Document Server

    Alessio, Federico

    2016-01-01

    In 2019, the LHCb experiment at CERN will undergo a major upgrade where its detectors electronics and entire readout system will be changed to read-out events at the full LHC rate of 40 MHz. In this paper, the new timing, trigger and readout control system for such upgrade is reviewed. Particular attention is given to the distribution of the clock, timing and synchronization information across the entire readout system using generic FTTH technology like Passive Optical Networks. Moreover the system will be responsible to generically control the Front-End electronics by transmitting configuration data and receiving monitoring data, offloading the software control system from the heavy task of manipulating complex protocols of thousands of Front-End electronics devices. The way in which this was implemented is here reviewed with a description of results from first implementations of the system, including usages in test-benches, implementation of techniques for timing distribution and latency control."

  14. Pixel detector readout chip

    CERN Multimedia

    1991-01-01

    Close-up of a pixel detector readout chip. The photograph shows an aera of 1 mm x 2 mm containing 12 separate readout channels. The entire chip contains 1000 readout channels (around 80 000 transistors) covering a sensitive area of 8 mm x 5 mm. The chip has been mounted on a silicon detector to detect high energy particles.

  15. A 10MS/s 8-bit charge-redistribution ADC for hybrid pixel applications in 65m CMOS

    CERN Document Server

    Kishishita, T; Krüger, H; Koch, M; Germic, L; Wermes, N

    2013-01-01

    The design and measurement results of an 8-bit SAR ADC, based on a charge-redistribution DAC, are presented. This ADC is characterized by superior power efficiency and small area, realized by employing a lateral metal–metal capacitor array and a dynamic two-stage comparator. To avoid the need for a highspeed clock and its associated power consumption, an asynchronous logic was implemented in a logic control cell. A test chip has been developed in a 65 nm CMOS technology, including eight ADC channels with different layout flavors of the capacitor array, a transimpedance amplifier as a signal input structure, a serializer, and a custom-made LVDS driver for data transmission. The integral (INL) and differential (DNL) nonlinearities are measured below 0.5 LSB and 0.8 LSB, respectively, for the best channel operating at a sampling frequency of 10 MS/s. The area occupies 40 μm 70 μm for one ADC channel. The power consumption is estimated as 4 μW at 1 MS/s and 38 μW at 10 MS/s with a supply rail of 1.2 V. Th...

  16. PI-RADS v2 and ADC values: is there room for improvement?

    Science.gov (United States)

    Jordan, Eric J; Fiske, Charles; Zagoria, Ronald; Westphalen, Antonio C

    2018-03-17

    To determine the diagnostic accuracy of ADC values in combination with PI-RADS v2 for the diagnosis of clinically significant prostate cancer (CS-PCa) compared to PI-RADS v2 alone. This retrospective study included 155 men whom underwent 3-Tesla prostate MRI and subsequent MR/US fusion biopsies at a single non-academic center from 11/2014 to 3/2016. All scans were performed with a surface coil and included T2, diffusion-weighted, and dynamic contrast-enhanced sequences. Suspicious findings were classified using Prostate Imaging Reporting and Data System (PI-RADS) v2 and targeted using MR/US fusion biopsies. Mixed-effect logistic regression analyses were used to determine the ability of PIRADS v2 alone and combined with ADC values to predict CS-PCa. As ADC categories are more practical in clinical situations than numeric values, an additional model with ADC categories of ≤ 800 and > 800 was performed. A total of 243 suspicious lesions were included, 69 of which were CS-PCa, 34 were Gleason score 3+3 PCa, and 140 were negative. The overall PIRADS v2 score, ADC values, and ADC categories are independent statistically significant predictors of CS-PCa (p values or categories is better discrimination of PI-RADS v2 4 lesions. ADC values and categories help to diagnose CS-PCa when lesions are assigned a PI-RADS v2 score of 4.

  17. Antibody-Drug Conjugates (ADCs) for Personalized Treatment of Solid Tumors: A Review.

    Science.gov (United States)

    Lambert, John M; Morris, Charles Q

    2017-05-01

    Attaching a cytotoxic "payload" to an antibody to form an antibody-drug conjugate (ADC) provides a mechanism for selective delivery of the cytotoxic agent to cancer cells via the specific binding of the antibody to cancer-selective cell surface molecules. The first ADC to receive marketing authorization was gemtuzumab ozogamicin, which comprises an anti-CD33 antibody conjugated to a highly potent DNA-targeting antibiotic, calicheamicin, approved in 2000 for treating acute myeloid leukemia. It was withdrawn from the US market in 2010 following an unsuccessful confirmatory trial. The development of two classes of highly potent microtubule-disrupting agents, maytansinoids and auristatins, as payloads for ADCs resulted in approval of brentuximab vedotin in 2011 for treating Hodgkin lymphoma and anaplastic large cell lymphoma, and approval of ado-trastuzumab emtansine in 2013 for treating HER2-positive breast cancer. Their success stimulated much research into the ADC approach, with >60 ADCs currently in clinical evaluation, mostly targeting solid tumors. Five ADCs have advanced into pivotal clinical trials for treating various solid tumors-platinum-resistant ovarian cancer, mesothelioma, triple-negative breast cancer, glioblastoma, and small cell lung cancer. The level of target expression is a key parameter in predicting the likelihood of patient benefit for all these ADCs, as well as for the approved compound, ado-trastuzumab emtansine. The development of a patient selection strategy linked to target expression on the tumor is thus critically important for identifying the population appropriate for receiving treatment.

  18. Development of the specialized integrated circuit for signal readout from micro-strip structures of a coordinate detectors

    International Nuclear Information System (INIS)

    Aulchenko, V.; Shekhtman, L.; Zhulanov, V.

    2015-01-01

    The paper presents current status of development of a specialized 64-channel integrated circuit (IC, ASIC) for front-end electronics of coordinate detectors in the Budker INP. The ASIC is produced using 180 nm process. During the recording phase the IC allows integration of short current pulses from strips of a coordinate sensor, and storing of up to 100 corresponding charge values in the analogue memory with minimum time interval of 100 ns. Maximum input charge is equal to 2×10 6 electrons, equivalent noise charge is ∼2.7×10 3 electrons. Conversion of the data, stored in the analogue memory, to digital form is performed by an external ADC during the readout through an analogue multiplexer

  19. Development of an ADC Radiation Tolerance Characterization System for the Upgrade of the ATLAS LAr Calorimeter

    CERN Document Server

    INSPIRE-00445642; Chen, Kai; Kierstead, James; Lanni, Francesco; Takai, Helio; Jin, Ge

    2016-01-01

    ATLAS LAr calorimeter will perform its Phase-I upgrade during the long shut down (LS2) in 2018, a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multichannel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for LTDB. In order to evaluate the radiation tolerance of these back up commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, which has ADC driver and clock distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as DAQ board. The data from ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed wit...

  20. Regional ADC values of the normal brain: differences due to age, gender, and laterality.

    Science.gov (United States)

    Naganawa, Shinji; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo; Ishigaki, Takeo

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean+/-standard deviation 2.3+/-1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (pright frontal, bilateral thalamus, and temporal (pbrain and may be useful for the future quantitative study as a reference.

  1. Fast readout of the COMPASS RICH CsI-MWPC chambers

    CERN Document Server

    Abbon, P; Deschampbs, H; Kunne, F; Gerasimov, S; Ketzer, B; Konorov, I; Kravtchuk, N; Magnon, A; Neyret, D; Panebianco, S; Paul, S; Rebourgeard, P; Tessaroto, F

    2006-01-01

    A new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon microstrip detectors, is shown to perform well even with “slow” signals from a MWPC, keeping a signal-to-noise ratio of 9. For every trigger the system reads three consecutive in-time samples, thus allowing to extract information on the signal shape and its timing. The effective time window is reduced from ∼3 μs for the Gassiplex to below 400 ns for the APV25-S1 chip, reducing pile-up events at high particle rate. A significant improvement of the signal-to-background ratio by a factor 5–6 with respect to the original readout has been measured in the central region of the RICH detector. Due to its pipelined architecture, the new readout system also considerably reduces the dead time per event, allowing efficien...

  2. High-speed crystal detection and characterization using a fast-readout detector.

    Science.gov (United States)

    Aishima, Jun; Owen, Robin L; Axford, Danny; Shepherd, Emma; Winter, Graeme; Levik, Karl; Gibbons, Paul; Ashton, Alun; Evans, Gwyndaf

    2010-09-01

    A novel raster-scanning method combining continuous sample translation with the fast readout of a Pilatus P6M detector has been developed on microfocus beamline I24 at Diamond Light Source. This fast grid-scan tool allows the rapid evaluation of large sample volumes without the need to increase the beam size at the sample through changes in beamline hardware. A slow version is available for slow-readout detectors. Examples of grid-scan use in centring optically invisible samples and in detecting and characterizing numerous microcrystals on a mesh-like holder illustrate the most common applications of the grid scan now in routine use on I24.

  3. Design and development of CAMAC 12 bit ADC/DAC dual purpose module

    International Nuclear Information System (INIS)

    Kulkarni, S.G.; Gore, J.A.; Ramlal, V.; Matkar, U.V.; Lokare, R.N.; Yadav, M.L.; Ekambaram, M.; Gupta, A.K.; Datar, V.M.

    2013-01-01

    A dual function CAMAC module is designed for Pelletron Accelerator which can function as 12 bit 8 channels DAC or 12 bit 16 channels ADC. Spartan 2 series of FPGA is used for implementing the CAMAC interface logic as well as logic for ADC/DAC interface. The PCB has both the ADC and DAC mounted but the module can have only one function selected due to wiring constraint. Two different VHDL programs (one for the ADC and other for the DAC) reside on the EEPROM permitting selection of any one as per the functionality required. The module is working as a 12 bit DAC at BARC-TIFR Pelletron Linac Facility, successfully. (author)

  4. Diagnostic value of ADC in patients with prostate cancer: influence of the choice of b values.

    Science.gov (United States)

    Thörmer, Gregor; Otto, Josephin; Reiss-Zimmermann, Martin; Seiwerts, Matthias; Moche, Michael; Garnov, Nikita; Franz, Toni; Do, Minh; Stolzenburg, Jens-Uwe; Horn, Lars-Christian; Kahn, Thomas; Busse, Harald

    2012-08-01

    To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm(2)) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS= 1.6 ± 0.3) and second best (1.1 ± 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score ≤ 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 ± 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's ρ -0.38 to -0.46, P < 0.05) with Gleason score. Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. • Absolute ADC values are highly dependent on the choice of b values. • Absolute ADC thresholds should be used carefully to predict tumour aggressiveness. • Subjective ratings of ADC maps involving b = 0 s/mm ( 2 ) are poor to fair. • Minimum b value greater than 0 s/mm ( 2 ) is recommended for ADC calculation.

  5. An offset cancellation technique in a switched-capacitor comparator for SAR ADCs

    International Nuclear Information System (INIS)

    Tong Xingyuan; Zhu Zhangming; Yang Yintang

    2012-01-01

    An offset cancellation technique for a SAR (successive approximation register) ADC switched-capacitor comparator is described. The comparator is designed with a pre-amplifying and regenerative latching structure and realized in 0.18 μm CMOS. With the first stage preamplifier offset cancellation and low offset regenerative latching approach, the equivalent offset of the comparator is reduced to < 0.55 mV. By using the pre-amplifying and regenerative latching comparison mode the comparator exhibits low power dissipation. Under a 1.8 V power supply, with a 200 kS/s ADC sampling rate and 3 MHz clock frequency, a 13-bit comparison resolution is reached and less than 0.09 mW power dissipation is consumed. The superiority of this comparator is discussed and proved by the post-simulation and application to a 10 bit 200 kS/s touch screen SAR A/D converter. (semiconductor integrated circuits)

  6. Comparison of ADC values in different malignancies of the skeletal musculature: a multicentric analysis

    International Nuclear Information System (INIS)

    Surov, Alexey; Nagata, Shuji; Razek, Ahmed A. Abd; Tirumani, Sree Harsha; Wienke, Andreas; Kahn, Thomas

    2015-01-01

    Diffusion-weighted imaging (DWI) provides essential information regarding tumor composition, such as cellularity and/or perfusion. DWI is helpful in distinguishing between malignant and benign lesions. Malignant intramuscular/soft tissue lesions consist of a wide spectrum of tumors that have different cell counts and matrix. It is presumed that these different tumors have different DWI findings and have different apparent diffusion coefficient (ADC) values. The aim of this study was to analyze DWI findings of different intramuscular malignancies in a multicentric study by using a standardized DWI protocol, and to compare the ADC values acquired. The data banks of four radiology departments were screened retrospectively for malignant intramuscular tumors. Only lesions that were investigated by MRI (with a 1.5-T scanner) using DWI (multishot EPI sequence with b values of 0 and 1,000 s/mm 2 ) were included in the study. Overall, 51 patients (28 women, 23 men; mean age 58.8 ± 16.1 years) with 57 different malignant intramuscular lesions were collected. In every case apparent diffusion constant (ADC) maps were calculated. In 14 patients muscle lymphoma, 11 patients intramuscular metastases from different primary tumors, and in 26 cases several muscle sarcomas were identified. The mean ADC value of the estimated lesions was 1.24 ± 0.53 x 10 -3 mm 2 s -1 , median value, 1.11 x 10 -3 mm 2 s -1 , range, 0.54-2.9 x 10 -3 mm 2 s -1 . The mean ADC value in muscle metastases was 1.28 ± 0.24 x 10 -3 mm 2 s -1 , in muscle lymphoma 0.76 ± 0.14 x 10 -3 mm 2 s -1 , and in muscle sarcomas 1.82 ± 0.63 x 10 -3 mm 2 s -1 . Muscle lymphoma showed statistically significant lower ADC values in comparison to muscle metastases (p = 0.01) and muscle sarcoma (p = 0.001). There was no significant differences between ADC values in muscle metastases and sarcomas (p = 0.48). ADC values in muscle lymphoma were homogeneous with less inter-patient variability and were within a relatively close

  7. Comparison of ADC values in different malignancies of the skeletal musculature: a multicentric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Surov, Alexey [Martin-Luther-University Halle-Wittenberg, Department of Radiology, Halle (Germany); University of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Nagata, Shuji [Kurume University School of Medicine, Department of Radiology, Kurume (Japan); Razek, Ahmed A. Abd [Mansoura Faculty of Medicine, Department of Diagnostic Radiology, Mansoura (Egypt); Tirumani, Sree Harsha [Harvard Medical School, Department of Imaging, Dana-Farber Cancer Institute and Department of Radiology, Brigham and Women' s Hospital, Boston, MA (United States); Wienke, Andreas [Martin-Luther-University Halle-Wittenberg, Institute of Medical Epidemiology, Biometry, and Statistics, Halle (Germany); Kahn, Thomas [University of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany)

    2015-04-28

    Diffusion-weighted imaging (DWI) provides essential information regarding tumor composition, such as cellularity and/or perfusion. DWI is helpful in distinguishing between malignant and benign lesions. Malignant intramuscular/soft tissue lesions consist of a wide spectrum of tumors that have different cell counts and matrix. It is presumed that these different tumors have different DWI findings and have different apparent diffusion coefficient (ADC) values. The aim of this study was to analyze DWI findings of different intramuscular malignancies in a multicentric study by using a standardized DWI protocol, and to compare the ADC values acquired. The data banks of four radiology departments were screened retrospectively for malignant intramuscular tumors. Only lesions that were investigated by MRI (with a 1.5-T scanner) using DWI (multishot EPI sequence with b values of 0 and 1,000 s/mm{sup 2}) were included in the study. Overall, 51 patients (28 women, 23 men; mean age 58.8 ± 16.1 years) with 57 different malignant intramuscular lesions were collected. In every case apparent diffusion constant (ADC) maps were calculated. In 14 patients muscle lymphoma, 11 patients intramuscular metastases from different primary tumors, and in 26 cases several muscle sarcomas were identified. The mean ADC value of the estimated lesions was 1.24 ± 0.53 x 10{sup -3} mm{sup 2}s{sup -1}, median value, 1.11 x 10{sup -3} mm{sup 2}s{sup -1}, range, 0.54-2.9 x 10{sup -3} mm{sup 2}s{sup -1}. The mean ADC value in muscle metastases was 1.28 ± 0.24 x 10{sup -3} mm{sup 2}s{sup -1}, in muscle lymphoma 0.76 ± 0.14 x 10{sup -3} mm{sup 2}s{sup -1}, and in muscle sarcomas 1.82 ± 0.63 x 10{sup -3} mm{sup 2}s{sup -1}. Muscle lymphoma showed statistically significant lower ADC values in comparison to muscle metastases (p = 0.01) and muscle sarcoma (p = 0.001). There was no significant differences between ADC values in muscle metastases and sarcomas (p = 0.48). ADC values in muscle lymphoma were

  8. A low power cyclic ADC design for a wireless monitoring system for orthopedic implants

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yi; Li Fule; Chen Hong; Zhang Chun; Wang Zhihua, E-mail: chenyi02@mails.tsinghua.edu.c [Tsinghua National Laboratory for Information Science and Technology, Institute of Microelectronics, Tsinghua University, Beijing 100084 (China)

    2009-08-15

    This paper presents a low power cyclic analog-to-digital convertor (ADC) design for a wireless monitoring system for orthopedic implants. A two-stage cyclic structure including a single to differential converter, two multiplying DAC functional blocks (MDACs) and some comparators is adopted, which brings moderate speed and moderate resolution with low power consumption. The MDAC is implemented with the common switched capacitor method. The 1.5-bit stage greatly simplifies the design of the comparator. The operational amplifier is carefully optimized both in schematic and layout for low power and offset. The prototype chip has been fabricated in a United Microelectronics Corporation (UMC) 0.18-{mu}m 1P6M CMOS process. The core of the ADC occupies only 0.12 mm{sup 2}. With a 304.7-Hz input and 4-kHz sampling rate, the measured peak SNDR and SFDR are 47.1 dB and 57.8 dBc respectively and its DNL and INL are 0.27 LSB and 0.3 LSB, respectively. The power consumption of the ADC is only 12.5 {mu}W in normal working mode and less than 150 nW in sleep mode. (semiconductor integrated circuits)

  9. Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Chun-chao; Liu, Xi; Peng, Wan-lin; Li, Lei; Zhang, Jin-ge [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Meng, Wen-jian; Deng, Xiang-bing [Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Zuo, Pan-li [Siemens Healthcare, MR Collaborations NE Asia, 100010, Beijing (China); Li, Zhen-lin, E-mail: lzlcd01@126.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2016-10-15

    Purpose: To determine whether readout-segmented echo-planar imaging (rs-EPI) diffusion-weighted imaging (DWI) can improve the image quality in patients with rectal cancer compared with single-shot echo-planar imaging (ss-EPI) DWI using 3.0 T magnetic resonance (MR) imaging. Materials and methods: This study was approved by the Institutional Review Board, and informed consent was obtained from all patients. Seventy-one patients with rectal cancer were enrolled in this study. For all patients, both rs-EPI and ss-EPI DWI were performed using a 3T MR scanner. Two radiologists independently assessed the overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures. The signal-to-noise ratio (SNR), lesion contrast, contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were also measured. Comparisons of the quantitative and qualitative parameters between the two sequences were performed using the paired t-test and the Wilcoxon signed rank test. Results: The scores of overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures of rs-EPI were all significantly higher than those of ss-EPI (all p < 0.05). The SNR and CNR were higher in rs-EPI than those in ss-EPI (all p < 0.05). There was no significant difference between ss-EPI and rs-EPI with regard to ROI size and mean ADCs of the tumour (p = 0.574 and p = 0.479, respectively), but the mean ADC of the normal tissue was higher in rs-EPI than in ss-EPI (1.73 ± 0.30 × 10{sup −3} mm{sup 2}/s vs. 1.60 ± 0.31 × 10{sup −3} mm{sup 2}/s, p = 0.001). Conclusions: DW imaging based on readout-segmented echo-planar imaging is a clinically useful technique to improve the image quality for the purpose of evaluating lesions in patients with rectal tumours.

  10. Particle identification via pulse-shape discrimination with a charge-integrating ADC

    International Nuclear Information System (INIS)

    Heltsley, J.H.; Brandon, L.; Galonsky, A.; Heilbronn, L.; Remington, B.A.; Langer, S.; Van der Molen, A.; Yurkon, J.; Michigan State Univ., East Lansing; Kasagi, J.

    1988-01-01

    A charge-integrating ADC has been used to sample the intensity in two different time regions of a pulse and thus to sense the shape of the pulse. This idea has been applied to produce neutron/γ-ray discrimination from pulses in a liquid scintillation detector. Optimization of available parameters yields good pulse-shape discrimination for pulses greater than those produced by 100 keV electrons. The method uses only general purpose electronics. (orig.)

  11. Design of a low power 10 bit 300 ksps multi-channel SAR ADC for wireless sensor network applications

    International Nuclear Information System (INIS)

    Hong Hui; Li Shiliang; Zhou Tao

    2015-01-01

    This paper presents a low power 10 bit 300 ksps successive approximation register analog-to-digital converter (SAR ADC) which is applied in wireless sensor network (WSN) applications. A single ended energy-saving split capacitor DAC array and a latch comparator with a rail to rail input stage are utilized to implement the ADC, which can reduce power dissipation while expanding the full scale input range and improve the signal-to-noise ratio (SNR). For power optimization the supply voltage of the SAR ADC is designed to be as low as 2 V. Four analog input channels are designed which make the ADC more suitable for WSN applications. The prototype circuit is fabricated using 3.3 V, 0.35 μm 2P4M CMOS technology and occupies an active chip area of 1.23 mm 2 . The test results show that the power dissipation is only 200 μW at a 2 V power supply and a sampling rate of 166 ksps. The calculated SNR is 58.25 dB, the ENOB is 9.38 bit and the FOM is 4.95 pJ/conversion-step. (paper)

  12. Online readout and control unit for high-speed/high resolution readout of silicon tracking detectors

    International Nuclear Information System (INIS)

    Buerger, J.; Hansen, K.; Lange, W.; Nowak, T.; Prell, S.; Zimmermann, W.

    1997-01-01

    We are describing a high speed VME readout and control module developed and presently working at the H1 experiment at DESY in Hamburg. It has the capability to read out 4 x 2048 analogue data channels at sampling rates up to 10 MHz with a dynamic input range of 1 V. The nominal resolution of the A/D converters can be adjusted between 8 and 12 bit. At the latter resolution we obtain signal-to-noise ratio better than 61.4 dB at a conversion rate of 5 MSps. At this data rate all 8192 detector channels can be read out to the internal raw data memory and VME interface within about 410 μs and 510 μs, respectively. The pedestal subtracted signals can be analyzed on-line. At a raw data hit occupation of 10%, the VME readout time is 50 μs per module. Each module provides four complementary CMOS signals to control the front-end electronics and four independent sets of power supplies for analogue and digital voltages (10 V, 100 mA) to drive the front-end electronics and for the bias voltage (100 V, 1.2 mA) to assure the full functionality of the detectors and the readout. (orig.)

  13. Online readout and control unit for high-speed/high resolution readout of silicon tracking detectors

    Science.gov (United States)

    Bürger, J.; Hansen, K.; Lange, W.; Nowak, T.; Prell, S.; Zimmermann, W.

    1997-02-01

    We are describing a high speed VME readout and control module developed and presently working at the H1 experiment at DESY in Hamburg. It has the capability to read out 4 × 2048 analogue data channels at sampling rates up to 10 MHz with a dynamic input range of 1 V. The nominal resolution of the A/D converters can be adjusted between 8 and 12 bit. At the latter resolution we obtain signal-to-noise ratio better than 61.4 dB at a conversion rate of 5 MSps. At this data rate all 8192 detector channels can be read out to the internal raw data memory and VME interface within about 410 μs and 510 μs, respectively. The pedestal subtracted signals can be analyzed on-line. At a raw data hit occupation of 10%, the VME readout time is 50 μs per module. Each module provides four complementary CMOS signals to control the front-end electronics and four independent sets of power supplies for analogue and digital voltages (10 V, 100 mA) to drive the front-end electronics and for the bias voltage (100 V, 1.2 mA) to assure the full functionality of the detectors and the readout.

  14. Online readout and control unit for high-speed / high resolution readout of silicon tracking detectors

    International Nuclear Information System (INIS)

    Buerger, J.; Hansen, K.; Lange, W.; Nowak, T.; Prell, S.; Zimmermann, W.

    1996-09-01

    We are describing a high speed VME readout and control module developed and presently working at the H1 experiment at DESY in Hamburg. It has the capability to read out 4 x 2048 analogue data channels at sampling rates up to 10 MHz with a dynamic input range of 1 V. The nominal resolution of the A/D converters can be adjusted between 8 and 12 bit. At the latter resolution we obtain signal-to-noise ratio better than 61.4 dB at a conversion rate of 5 MSps. At this data rate all 8192 detector channels can be read out to the internal raw data memory and VME interface within about 410 μs and 510 μs, respectively. The pedestal subtracted signals can be analyzed on-line. At a raw data hit occupation of 10%, the VME readout time is 50 μs per module. Each module provides four complementary CMOS signals to control the front-end electronics and four independent sets of power supplies for analogue and digital voltages (10 V, 100 mA) to drive the front-end electronics and for the bias voltage (100 V, 1.2 mA) to assure the full functionality of the detectors and the readout. (orig.)

  15. Diffusion-weighted (DW) MRI in lung cancers. ADC test-retest repeatability

    Energy Technology Data Exchange (ETDEWEB)

    Weller, Alex; Papoutsaki, Marianthi Vasiliki; Blackledge, Matthew; DeSouza, Nandita M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, CRUK Cancer Imaging Centre, Surrey (United Kingdom); Waterton, John C. [University of Manchester, Manchester (United Kingdom); Chiti, Arturo [Humanitas University, Milan (Italy); Stroobants, Sigrid [Universiteit Antwerpen, Antwerpen (Belgium); Kuijer, Joost [Vrije Universiteit Medisch Centrum, Amsterdam (Netherlands); Morgan, Veronica [Royal Marsden NHS Foundation Trust, Department of Medicine, London (United Kingdom)

    2017-11-15

    To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision. Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800 s/mm{sup -2}). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility. Whole-tumour ADC values ranged from 0.66-1.94x10{sup -3} mm{sup 2}s{sup -1} (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7-9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9-5.9%); and LoA -10.2 to 11.4%. Variability for lesions <3 cm was 2.46 times higher. ADC reproducibility across different post-processing platforms was excellent: Pearson's R{sup 2} = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%. A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change. (orig.)

  16. Diffusion-weighted magnetic resonance imaging with apparent diffusion coefficient (ADC) determination in normal and pathological fetal kidneys.

    Science.gov (United States)

    Chaumoitre, K; Colavolpe, N; Shojai, R; Sarran, A; D' Ercole, C; Panuel, M

    2007-01-01

    To assess the use of diffusion-weighted magnetic resonance imaging (DW-MRI) in the evaluation of the fetal kidney and to estimate age-dependent changes in the apparent diffusion coefficient (ADC) of normal and pathological fetal kidneys. DW-MRI was performed on a 1.5-T machine at 23-38 gestational weeks in 51 pregnant women in whom the fetal kidneys were normal and in 10 whose fetuses had renal pathology (three with suspected nephropathy, three with renal tract dilatation, one with unilateral renal venous thrombosis, and three with twin-twin transfusion syndrome (TTTS)). The ADC was measured in an approximately 1-cm2 region of interest within the renal parenchyma. ADC values in normal renal parenchyma ranged from 1.1 to 1.8 10(-3) mm2 s-1. There was no significant age-dependent change in the ADC of normal kidneys. In cases of nephropathy, the ADC value was not always pathological but an ADC map could show abnormal findings. In cases of dilatation, the ADC value was difficult to determine when the dilatation was huge. In cases of TTTS, the ADC of the donor twin was higher than that of the recipient twin and the difference seemed to be related to the severity of the syndrome. Evaluation of the ADC for fetal kidneys is feasible. Fetal measurement of the ADC value and ADC maps may be useful tools with which to explore the fetal kidney when used in conjunction with current methods. DW-MR images, ADC value and ADC map seem to be useful in cases of suspected nephropathy (hyperechoic kidneys), dilated kidney and vascular pathology (renal venous thrombosis, TTTS). Copyright (c) 2006 ISUOG.

  17. Fast readout of the COMPASS RICH CsI-MWPC photon chambers

    International Nuclear Information System (INIS)

    Abbon, P.; Delagnes, E.; Deschamps, H.; Kunne, F.; Gerasimov, S.; Ketzer, B.; Konorov, I.; Kravtchuk, N.; Magnon, A.; Neyret, D.; Panebianco, S.; Paul, S.; Rebourgeard, P.; Tessaroto, F.

    2006-01-01

    A new readout system for CsI-coated MWPCs, used in the COMPASS RICH detector, has been proposed and tested in nominal high-rate conditions. It is based on the APV25-S1 analog sampling chip, and will replace the Gassiplex chip readout used up to now. The APV chip, originally designed for silicon microstrip detectors, is shown to perform well even with 'slow' signals from a MWPC, keeping a signal-to-noise ratio of 9. For every trigger the system reads three consecutive in-time samples, thus allowing to extract information on the signal shape and its timing. The effective time window is reduced from ∼3 μs for the Gassiplex to below 400 ns for the APV25-S1 chip, reducing pile-up events at high particle rate. A significant improvement of the signal-to-background ratio by a factor 5-6 with respect to the original readout has been measured in the central region of the RICH detector. Due to its pipelined architecture, the new readout system also considerably reduces the dead time per event, allowing efficient data taking at higher trigger rate

  18. The Adc/Lmb System Mediates Zinc Acquisition in Streptococcus agalactiae and Contributes to Bacterial Growth and Survival.

    Science.gov (United States)

    Moulin, Pauline; Patron, Kévin; Cano, Camille; Zorgani, Mohamed Amine; Camiade, Emilie; Borezée-Durant, Elise; Rosenau, Agnès; Mereghetti, Laurent; Hiron, Aurélia

    2016-12-15

    The Lmb protein of Streptococcus agalactiae is described as an adhesin that binds laminin, a component of the human extracellular matrix. In this study, we revealed a new role for this protein in zinc uptake. We also identified two Lmb homologs, AdcA and AdcAII, redundant binding proteins that combine with the AdcCB translocon to form a zinc-ABC transporter. Expression of this transporter is controlled by the zinc concentration in the medium through the zinc-dependent regulator AdcR. Triple deletion of lmb, adcA, and adcAII, or that of the adcCB genes, impaired growth and cell separation in a zinc-restricted environment. Moreover, we found that this Adc zinc-ABC transporter promotes S. agalactiae growth and survival in some human biological fluids, suggesting that it contributes to the infection process. These results indicated that zinc has biologically vital functions in S. agalactiae and that, under the conditions tested, the Adc/Lmb transporter constitutes the main zinc acquisition system of the bacterium. A zinc transporter, composed of three redundant binding proteins (Lmb, AdcA, and AdcAII), was characterized in Streptococcus agalactiae This system was shown to be essential for bacterial growth and morphology in zinc-restricted environments, including human biological fluids. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  19. Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy.

    Science.gov (United States)

    Lahrsow, Maximilian; Albrecht, Moritz H; Bickford, Matthew W; Vogl, Thomas J

    2017-06-01

    To use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment. Fifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions. One month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10 -3  mm 2 /s) and no response (median 1.30 × 10 -3  mm 2 /s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC. In patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

  20. 17 bit 4.35 mW 1 kHz Delta Sigma ADC and 256-to-1 multiplexer for remote handling instrumentation equipment

    Energy Technology Data Exchange (ETDEWEB)

    Verbeeck, Jens, E-mail: jens.verbeeck@esat.kuleuven.be [KU Leuven, Department ESAT-MICAS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); KH Kempen University College, IBW-RELIC, Kleinhoefstraat 4, 2440 Geel (Belgium); Van Uffelen, Marco [Fusion for Energy, c/Josep, n° 2, Torres Diagonal Litoral, Ed. B3, 08019 Barcelona (Spain); Steyaert, Michiel [KU Leuven, Department ESAT-MICAS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); Leroux, Paul [KU Leuven, Department ESAT-MICAS, Kasteelpark Arenberg 10, 3001 Heverlee (Belgium); KH Kempen University College, IBW-RELIC, Kleinhoefstraat 4, 2440 Geel (Belgium)

    2013-10-15

    Highlights: ► We present a radiation hard 17 bit-1 kHz 4.35 mW Delta Sigma ADC. ► A radiation tolerant 256-to-1 multiplexer is shown. ► We propose a generic radiation tolerant ASIC for use in an instrumentation link. ► The ASIC can interface more than hundred pressure or resistive sensors. ► All building blocks have a simulated radiation tolerance of more than 1 MGy. -- Abstract: A radiation tolerant Delta-Sigma Analog-to-Digital Converter (ADC) and multiplexer is presented. The design features a 1.5 V, 17 bit ADC consuming 4.35 mW at a sample frequency of 1 MHz. The ADC features a bandwidth of 1 kHz and utilizes a Correlated Double Sampling technique (CDS) to remove offset and 1/f noise. The circuit maintains its 17 bit resolution upon a simulated radiation dose exceeding 1 MGy and varying temperatures between 0 °C and 85 °C. Next a multiplexer is presented. It can multiplex 256 channels at a clock frequency of 128 MHz or has a data throughput of 256 MSample/s. In addition the bit period of the multiplexer varies less then 1.5% due to the influence of temperature or radiation, which proves the temperature and radiation tolerance.

  1. A fast embedded readout system for large-area Medipix and Timepix systems

    International Nuclear Information System (INIS)

    Brogna, A S; Balzer, M; Smale, S; Hartmann, J; Bormann, D; Hamann, E; Cecilia, A; Zuber, M; Koenig, T; Weber, M; Fiederle, M; Baumbach, T; Zwerger, A

    2014-01-01

    In this work we present a novel readout electronics for an X-ray sensor based on a Si crystal bump-bonded to an array of 3 × 2 Medipix ASICs. The pixel size is 55 μm × 55 μm with a total number of ∼ 400k pixels and a sensitive area of 42 mm × 28 mm. The readout electronics operate Medipix-2 MXR or Timepix ASICs with a clock speed of 125 MHz. The data acquisition system is centered around an FPGA and each of the six ASICs has a dedicated I/O port for simultaneous data acquisition. The settings of the auxiliary devices (ADCs and DACs) are also processed in the FPGA. Moreover, a high-resolution timer operates the electronic shutter to select the exposure time from 8 ns to several milliseconds. A sophisticated trigger is available in hardware and software to synchronize the acquisition with external electro-mechanical motors. The system includes a diagnostic subsystem to check the sensor temperature and to control the cooling Peltier cells and a programmable high-voltage generator to bias the crystal. A network cable transfers the data, encapsulated into the UDP protocol and streamed at 1 Gb/s. Therefore most notebooks or personal computers are able to process the data and to program the system without a dedicated interface. The data readout software is compatible with the well-known Pixelman 2.x running both on Windows and GNU/Linux. Furthermore the open architecture encourages users to write their own applications. With a low-level interface library which implements all the basic features, a MATLAB or Python script can be implemented for special manipulations of the raw data. In this paper we present selected images taken with a microfocus X-ray tube to demonstrate the capability to collect the data at rates up to 120 fps corresponding to 0.76 Gb/s

  2. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging

    International Nuclear Information System (INIS)

    Giannotti, E.; Waugh, S.; Priba, L.; Davis, Z.; Crowe, E.; Vinnicombe, S.

    2015-01-01

    Highlights: • Inter-scan errors have minimal contribution to ADC measurement variability. • Intra-observer measures of ADC values in breast cancer are excellent. • ADC measures in whole tumour are more reproducible than minimum ADC measures. • ADC measurement error is most influenced by multiple readers. - Abstract: Purpose: Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan–scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Methods: Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26–61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29–70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADC S ) and the ADC value of a small region of interest (ROI) on the same slice (ADC min ). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Results: Scanner stability contributed 6% error to phantom ADC measurements (0.071 × 10 −3 mm 2 /s; mean ADC = 1.089 × 10 −3 mm 2 /s). The measured scan-scan CoR in the volunteers was 0.122 × 10 −3 mm 2 /s, contributing an error of 8% to the mean measured values (ADC scan1 = 1.529 × 10 −3 mm 2 /s; ADC scan

  3. Discrimination between intact and decayed pulp regions in carious teeth by ADC mapping.

    Science.gov (United States)

    Cankar, Ksenija; Nemeth, Lidija; Bajd, Franci; Vidmar, Jernej; Serša, Igor

    2014-01-01

    The aim of this study was to evaluate an advanced magnetic resonance imaging (MRI) method, apparent diffusion coefficient (ADC) mapping, in the functional assessment of carious teeth. 38 extracted human teeth with scores of 0, 3 and 6 according to International Caries Detection and Assessment System (ICDAS) criteria were screened and subsequently analyzed by MRI at 2.35 T. Histology sectioning of teeth was used for the gold standard by analyzing two extreme cases (intact and severely decayed). ADC maps of the same teeth were calculated from corresponding diffusion-weighted images and used to obtain ADC distributions along dental pulp as functions of the relative pulp length measured from the occlusal pulp side. The measured distributions were analyzed for the best fit by a four-parameter three-segment linear regression model for ADC distribution along the pulp. MRI results were in good agreement with findings in histological sections of identical teeth. The best fit model parameters, relative decayed region depth, relative transition region width and ADC values of intact and decayed pulp tissue, showed statistically significant differences between the ADC values of intact and decayed pulp tissue (1.0 × 10(-9) m(2)/s vs. 0.74-0.89 × 10(-9) m(2)/s) and the relative decayed region depth progressing with ICDAS score (3 vs. 46% with ICDAS 3 vs. ICDAS 6). The results of this feasibility study confirmed relevance of ADC mapping for the discrimination and localization of intact and decayed regions in dental pulps of carious teeth. © 2014 S. Karger AG, Basel.

  4. Design and characterization of a 12-bit 10MS/s 10mW pipelined SAR ADC for CZT-based hard X-ray imager

    Science.gov (United States)

    Xue, F.; Gao, W.; Duan, Y.; Zheng, R.; Hu, Y.

    2018-02-01

    This paper presents a 12-bit pipelined successive approximation register (SAR) ADC for CZT-based hard X-ray Imager. The proposed ADC is comprised of a first-stage 6-bit SAR-based Multiplying Digital Analog Converter (MDAC) and a second-stage 8-bit SAR ADC. A novel MDAC architecture using Vcm-based Switching method is employed to maximize the energy efficiency and improve the linearity of the ADC. Moreover, the unit-capacitor array instead of the binary-weighted capacitor array is adopted to improve the conversion speed and linearity of the ADC in the first-stage MDAC. In addition, a new layout design method for the binary-weighted capacitor array is proposed to reduce the capacitor mismatches and make the routing become easier and less-time-consuming. Finally, several radiation-hardened-by-design technologies are adopted in the layout design against space radiation effects. The prototype chip was fabricated in 0.18 μm mixed-signal 1.8V/3.3V process and operated at 1.8 V supply. The chip occupies a core area of only 0.58 mm2. The proposed pipelined SAR ADC achieves a peak signal-to-noise-and-distortion ratio (SNDR) of 66.7 dB and a peak spurious-free dynamic range (SFDR) of 78.6 dB at 10 MS/s sampling rate and consumes 10 mW. The figure of merit (FOM) of the proposed ADC is 0.56 pJ/conversion-step.

  5. Regional ADC values of the normal brain: differences due to age, gender, and laterality

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Ishigaki, Takeo [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 466-8550 (Japan); Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo [Department of Radiology, First Kamiida General Hospital (Japan)

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean{+-}standard deviation 2.3{+-}1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference. (orig.)

  6. Regional ADC values of the normal brain: differences due to age, gender, and laterality

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Ishigaki, Takeo; Sato, Kimihide; Katagiri, Toshio; Mimura, Takeo

    2003-01-01

    The purpose of this study was to evaluate the stability of measurement for apparent diffusion coefficient (ADC) values in normal brain, to clarify the effect of aging on ADC values, to compare ADC values between men and women, and to compare ADC values between right and left sides of the brain. To evaluate the stability of measurements, five normal volunteers (four men and one woman) were examined five times on different days. Then, 294 subjects with normal MR imaging (147 men and 147 women; age range 20-89 years) were measured. The ADC measurement in normal volunteers was stable. The ADC values stayed within the 5% deviation of average values in all volunteers (mean±standard deviation 2.3±1.2%). The ADC values gradually increased by aging in all regions. In thalamus, no significant difference was seen between right and left in the subjects under 60 years; however, right side showed higher values in the subjects over 60 years (p<0.01). In the subjects under 60 years, women showed higher values in right frontal, bilateral thalamus, and temporal (p<0.01); however, in the subjects over 60 years, no region showed difference between men and women. The knowledge obtained in this study may be helpful to understand the developmental and aging mechanisms of normal brain and may be useful for the future quantitative study as a reference. (orig.)

  7. Diffusion-weighted MRI in prostatic lesions: Diagnostic performance of normalized ADC using normal peripheral prostatic zone as a reference

    Directory of Open Access Journals (Sweden)

    Tamer F. Taha Ali

    2018-03-01

    Full Text Available Aim of study: Evaluate the potential value of the normal peripheral zone as a reference organ to normalize prostatic lesion apparent diffusion coefficient (ADC to improve its evaluation of prostatic lesions. Patients and methods: This prospective study included 38 patients with clinical suspicion of cancer prostate (increased PSA levels (>4 ng/ml, hard prostate in digital rectal examination and who are scheduled to undergo a TRUS-guided biopsy. Conventional and DW-MRI was done and ADC was calculated. The normalized ADC value was calculated by dividing the ADC of lesion by ADC of reference site (healthy peripheral zone. DWI-MRI results were compared to the results of biopsy. Comparison of ADCs and nADCs of benign and malignant lesions was done. Receiver operating characteristics (ROC curve analysis was done. Results: The patients were classified by histopathology into non-malignant group (16 patients and malignant group (22 patients. Significant negative correlation between ADC and normalized ADC (nADC and malignancy was detected. There was no significant difference between the mean ADC of peripheral health prostatic zones (PZ between benign and malignant cases (2.221 ± 0.356 versus 1.99 ± 0.538x10−3 mm2/sec, p = 0.144.There was significant difference between the mean ADC and mean nADC in benign and malignant lesions (1.049 ± 0.217 versus 0.659 ± 0.221x10−3 mm2/sec, p < 0.001 and (0.475 ± 0.055 versus 0.328 ± 0.044, p < 0.001 respectively.There was significant higher diagnostic performance of nADC than ADC with ADC Cut-off value 0.75 × 10−3 mm2/sec and nADC cut-off value 0.39 could significantly differentiate between benign and malignant lesion with sensitivity, specificity, PPV,NPV of 86.36,75,82.61 and 80% respectively, p < 0.0001 for ADC and 95.45, 93.75, 95.45 and 93.75%, p < 0.0001 for nADC. Conclusion: diagnostic performance of nADC using normal peripheral zone is higher than

  8. A frame simulator for data produced by 'multi-accumulation' readout detectors

    Science.gov (United States)

    Bonoli, Carlotta; Bortoletto, Favio; Giro, Enrico; Corcione, Leonardo; Ligori, Sebastiano; Nicastro, Luciano

    2010-07-01

    A simulator of data frames produced by 'multi-accumulation' readout detectors has been developed during the feasibility study for the NIS spectrograph, part of the European Euclid mission. The software can emulate various readout strategies, allowing to compare the efficiency of different sampling techniques. Special care is given to two crucial aspects: the minimization of the noise and the effects produced by cosmic hits. The resulting readout noise is analyzed as a function of the background sources, detector native characteristics and readout strategy, while the image deterioration by cosmic rays covers the simulation of hits and their correction efficiency varying the readout modalities. Simulated "multi-accumulation" frames, typical of multiplexer based detectors, are an ideal tool for testing the efficiency of cosmic ray rejection techniques. In the present case cosmic rays are added to each raw frame conforming to the rates and energy expected in the operational L2 region and in the chosen exposure time. Procedures efficiency for cosmic ray identification and correction can also be easily tested in terms of memory occupancy and telemetry rates.

  9. Diagnostic value of ADC in patients with prostate cancer: influence of the choice of b values

    International Nuclear Information System (INIS)

    Thoermer, Gregor; Otto, Josephin; Reiss-Zimmermann, Martin; Seiwerts, Matthias; Moche, Michael; Garnov, Nikita; Kahn, Thomas; Busse, Harald; Franz, Toni; Do, Minh; Stolzenburg, Jens-Uwe; Horn, Lars-Christian

    2012-01-01

    To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm 2 ) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS = 1.6 ± 0.3) and second best (1.1 ± 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score ≤ 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 ± 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's ρ -0.38 to -0.46, P < 0.05) with Gleason score. Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. (orig.)

  10. Diagnostic value of ADC in patients with prostate cancer: influence of the choice of b values

    Energy Technology Data Exchange (ETDEWEB)

    Thoermer, Gregor; Otto, Josephin; Reiss-Zimmermann, Martin; Seiwerts, Matthias; Moche, Michael; Garnov, Nikita; Kahn, Thomas; Busse, Harald [Leipzig University Hospital, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Franz, Toni; Do, Minh; Stolzenburg, Jens-Uwe [Leipzig University Hospital, Department of Urology, Leipzig (Germany); Horn, Lars-Christian [University of Leipzig, Institute of Pathology, Leipzig (Germany)

    2012-08-15

    To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm{sup 2}) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS = 1.6 {+-} 0.3) and second best (1.1 {+-} 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score {<=} 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 {+-} 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's {rho} -0.38 to -0.46, P < 0.05) with Gleason score. Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. (orig.)

  11. ADC histogram analysis for adrenal tumor histogram analysis of apparent diffusion coefficient in differentiating adrenal adenoma from pheochromocytoma.

    Science.gov (United States)

    Umanodan, Tomokazu; Fukukura, Yoshihiko; Kumagae, Yuichi; Shindo, Toshikazu; Nakajo, Masatoyo; Takumi, Koji; Nakajo, Masanori; Hakamada, Hiroto; Umanodan, Aya; Yoshiura, Takashi

    2017-04-01

    To determine the diagnostic performance of apparent diffusion coefficient (ADC) histogram analysis in diffusion-weighted (DW) magnetic resonance imaging (MRI) for differentiating adrenal adenoma from pheochromocytoma. We retrospectively evaluated 52 adrenal tumors (39 adenomas and 13 pheochromocytomas) in 47 patients (21 men, 26 women; mean age, 59.3 years; range, 16-86 years) who underwent DW 3.0T MRI. Histogram parameters of ADC (b-values of 0 and 200 [ADC 200 ], 0 and 400 [ADC 400 ], and 0 and 800 s/mm 2 [ADC 800 ])-mean, variance, coefficient of variation (CV), kurtosis, skewness, and entropy-were compared between adrenal adenomas and pheochromocytomas, using the Mann-Whitney U-test. Receiver operating characteristic (ROC) curves for the histogram parameters were generated to differentiate adrenal adenomas from pheochromocytomas. Sensitivity and specificity were calculated by using a threshold criterion that would maximize the average of sensitivity and specificity. Variance and CV of ADC 800 were significantly higher in pheochromocytomas than in adrenal adenomas (P histogram parameters for diagnosing adrenal adenomas (ADC 200 , 0.82; ADC 400 , 0.87; and ADC 800 , 0.92), with sensitivity of 84.6% and specificity of 84.6% (cutoff, ≤2.82) with ADC 200 ; sensitivity of 89.7% and specificity of 84.6% (cutoff, ≤2.77) with ADC 400 ; and sensitivity of 94.9% and specificity of 92.3% (cutoff, ≤2.67) with ADC 800 . ADC histogram analysis of DW MRI can help differentiate adrenal adenoma from pheochromocytoma. 3 J. Magn. Reson. Imaging 2017;45:1195-1203. © 2016 International Society for Magnetic Resonance in Medicine.

  12. Multi-parameter CAMAC compatible ADC scanner

    Energy Technology Data Exchange (ETDEWEB)

    Midttun, G J; Ingebretsen, F [Oslo Univ. (Norway). Fysisk Inst.; Johnsen, P J [Norsk Data A.S., Box 163, Oekern, Oslo 5, Norway

    1979-02-15

    A fast ADC scanner for multi-parameter nuclear physics experiments is described. The scanner is based on a standard CAMAC crate, and data from several different experiments can be handled simultaneously through a direct memory access (DMA) channel. The implementation on a PDP-7 computer is outlined.

  13. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giannotti, E., E-mail: ytteb84@hotmail.com [Breast Imaging Department, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Waugh, S., E-mail: shelley.waugh@nhs.net [Department of Medical Physics, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Department of Clinical Radiology, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Priba, L., E-mail: lpriba@nhs.net [Department of Medical Physics, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Davis, Z., E-mail: zoedavis@doctors.org.uk [Breast Imaging Department, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Crowe, E., E-mail: e.crowe@nhs.net [Department of Clinical Radiology, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Vinnicombe, S., E-mail: s.vinnicombe@dundee.ac.uk [Division of Imaging and Technology, Ninewells Hospital and Medical School, University of Dundee, Dundee DD1 9SY (United Kingdom)

    2015-09-15

    Highlights: • Inter-scan errors have minimal contribution to ADC measurement variability. • Intra-observer measures of ADC values in breast cancer are excellent. • ADC measures in whole tumour are more reproducible than minimum ADC measures. • ADC measurement error is most influenced by multiple readers. - Abstract: Purpose: Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan–scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Methods: Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26–61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29–70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADC{sub S}) and the ADC value of a small region of interest (ROI) on the same slice (ADC{sub min}). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Results: Scanner stability contributed 6% error to phantom ADC measurements (0.071 × 10{sup −3} mm{sup 2}/s; mean ADC = 1.089 × 10{sup −3} mm{sup 2}/s). The measured scan-scan CoR in the volunteers was 0.122 × 10{sup −3} mm{sup 2}/s, contributing an error of 8% to the mean measured values (ADC

  14. Readout electronic for multichannel detectors

    CERN Document Server

    Kulibaba, V I; Naumov, S V

    2001-01-01

    Readout electronics based on the 128-channel chip 'Viking' (IDE AS inc., Norway) is considered. The chip 'Viking' integrates 128 low noise charge-sensitive preamplifiers with tunable CR-(RC) sup 2 shapers,analog memory and multiplexed readout to one output. All modules of readout electronics were designed and produced in KIPT taking into account the published recommendations of IDE AS inc.

  15. Readout electronic for multichannel detectors

    International Nuclear Information System (INIS)

    Kulibaba, V.I.; Maslov, N.I.; Naumov, S.V.

    2001-01-01

    Readout electronics based on the 128-channel chip 'Viking' (IDE AS inc., Norway) is considered. The chip 'Viking' integrates 128 low noise charge-sensitive preamplifiers with tunable CR-(RC) 2 shapers,analog memory and multiplexed readout to one output. All modules of readout electronics were designed and produced in KIPT taking into account the published recommendations of IDE AS inc

  16. A 10 MS/s 8-bit charge-redistribution ADC for hybrid pixel applications in 65 m CMOS

    International Nuclear Information System (INIS)

    Kishishita, Tetsuichi; Hemperek, Tomasz; Krüger, Hans; Koch, Manuel; Germic, Leonard; Wermes, Norbert

    2013-01-01

    The design and measurement results of an 8-bit SAR ADC, based on a charge-redistribution DAC, are presented. This ADC is characterized by superior power efficiency and small area, realized by employing a lateral metal–metal capacitor array and a dynamic two-stage comparator. To avoid the need for a high-speed clock and its associated power consumption, an asynchronous logic was implemented in a logic control cell. A test chip has been developed in a 65 nm CMOS technology, including eight ADC channels with different layout flavors of the capacitor array, a transimpedance amplifier as a signal input structure, a serializer, and a custom-made LVDS driver for data transmission. The integral (INL) and differential (DNL) nonlinearities are measured below 0.5 LSB and 0.8 LSB, respectively, for the best channel operating at a sampling frequency of 10 MS/s. The area occupies 40μm×70μm for one ADC channel. The power consumption is estimated as 4μW at 1 MS/s and 38μW at 10 MS/s with a supply rail of 1.2 V. These excellent performance features and the natural radiation hardness of the design, due to the thin gate oxide thickness of transistors, are very interesting for front-end electronics ICs of future hybrid-pixel detector systems

  17. A 10 MS/s 8-bit charge-redistribution ADC for hybrid pixel applications in 65 m CMOS

    Energy Technology Data Exchange (ETDEWEB)

    Kishishita, Tetsuichi, E-mail: kisisita@physik.uni-bonn.de; Hemperek, Tomasz; Krüger, Hans; Koch, Manuel; Germic, Leonard; Wermes, Norbert

    2013-12-21

    The design and measurement results of an 8-bit SAR ADC, based on a charge-redistribution DAC, are presented. This ADC is characterized by superior power efficiency and small area, realized by employing a lateral metal–metal capacitor array and a dynamic two-stage comparator. To avoid the need for a high-speed clock and its associated power consumption, an asynchronous logic was implemented in a logic control cell. A test chip has been developed in a 65 nm CMOS technology, including eight ADC channels with different layout flavors of the capacitor array, a transimpedance amplifier as a signal input structure, a serializer, and a custom-made LVDS driver for data transmission. The integral (INL) and differential (DNL) nonlinearities are measured below 0.5 LSB and 0.8 LSB, respectively, for the best channel operating at a sampling frequency of 10 MS/s. The area occupies 40μm×70μm for one ADC channel. The power consumption is estimated as 4μW at 1 MS/s and 38μW at 10 MS/s with a supply rail of 1.2 V. These excellent performance features and the natural radiation hardness of the design, due to the thin gate oxide thickness of transistors, are very interesting for front-end electronics ICs of future hybrid-pixel detector systems.

  18. An 'ADC-Memory' system based on a new principle in data access

    International Nuclear Information System (INIS)

    Pan Dajing; Wu Yongqing; Wang Shibo

    1990-01-01

    A new kind of 'ADC-Memory' (ADC-M) with real time correction of counting loss in dead time is now used in a multiuser data acquisition and processing system based on DUAL/68000 microcomputer. In data access, it replaces the 'DMA + 1' in classical MCA with the new method 'DMA + N', where N is weight factor of correction. The new method is based on the principle of virtual pulse generator. This method is superior to the correction by the software because the correction needn't take the computer time. Thus, this ADC-M can be used in the counting of high rate pulses

  19. ADC texture—An imaging biomarker for high-grade glioma?

    Energy Technology Data Exchange (ETDEWEB)

    Brynolfsson, Patrik; Hauksson, Jón; Karlsson, Mikael; Garpebring, Anders; Nyholm, Tufve, E-mail: tufve.nyholm@radfys.umu.se [Department of Radiation Sciences, Radiation Physics, Umeå University, Umeå SE-901 87 (Sweden); Nilsson, David; Trygg, Johan [Computational Life Science Cluster (CLiC), Department of Chemistry, Umeå University, Umeå SE-901 87 (Sweden); Henriksson, Roger [Department of Radiation Sciences, Oncology, Umeå University, Umeå SE-901 87, Sweden and Regionalt Cancercentrum Stockholm, Karolinska Universitetssjukhuset, Solna, Stockholm SE-102 39 (Sweden); Birgander, Richard [Department of Radiation Sciences, Diagnostic Radiology, Umeå University, Umeå SE-901 87 (Sweden); Asklund, Thomas [Department of Radiation Sciences, Oncology, Umeå University, Umeå SE-901 87 (Sweden)

    2014-10-15

    Purpose: Survival for high-grade gliomas is poor, at least partly explained by intratumoral heterogeneity contributing to treatment resistance. Radiological evaluation of treatment response is in most cases limited to assessment of tumor size months after the initiation of therapy. Diffusion-weighted magnetic resonance imaging (MRI) and its estimate of the apparent diffusion coefficient (ADC) has been widely investigated, as it reflects tumor cellularity and proliferation. The aim of this study was to investigate texture analysis of ADC images in conjunction with multivariate image analysis as a means for identification of pretreatment imaging biomarkers. Methods: Twenty-three consecutive high-grade glioma patients were treated with radiotherapy (2 Gy/60 Gy) with concomitant and adjuvant temozolomide. ADC maps and T1-weighted anatomical images with and without contrast enhancement were collected prior to treatment, and (residual) tumor contrast enhancement was delineated. A gray-level co-occurrence matrix analysis was performed on the ADC maps in a cuboid encapsulating the tumor in coronal, sagittal, and transversal planes, giving a total of 60 textural descriptors for each tumor. In addition, similar examinations and analyses were performed at day 1, week 2, and week 6 into treatment. Principal component analysis (PCA) was applied to reduce dimensionality of the data, and the five largest components (scores) were used in subsequent analyses. MRI assessment three months after completion of radiochemotherapy was used for classifying tumor progression or regression. Results: The score scatter plots revealed that the first, third, and fifth components of the pretreatment examinations exhibited a pattern that strongly correlated to survival. Two groups could be identified: one with a median survival after diagnosis of 1099 days and one with 345 days, p = 0.0001. Conclusions: By combining PCA and texture analysis, ADC texture characteristics were identified, which seems

  20. A new data acquisition system for pelletron-LINAC experiments

    International Nuclear Information System (INIS)

    Ramachandran, K.; Chatterjee, A.; Singh, Sudheer; Jha, K.; Joy, Saju; Behere, A.; Goadgoankar, M.D.

    2007-01-01

    The LINAC booster facility coupled with Pelletron accelerator at Mumbai and the plans to have large detector arrays such as Indian National Gamma Array, Charged Particle Array, Neutron Array, BaF 2 etc. pose new challenges to have a Data Acquisition system (DAQ) with a throughput an order of magnitude higher than the present CAMAC system. The major limitation of CAMAC readout is the 1μs/word readout time. A new FERA (Fast Encoding and Readout) data acquisition system developed at BARC for the augmentation of the throughput of CAMAC is a readout bus for the CAMAC ADCs. With this FERA DAQ, it is possible to readout CAMAC ADC's at 150 ns/word. This talk will present the new DAQ system used at BARC-TIFR Pelletron Accelerator facility. (author)

  1. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    Energy Technology Data Exchange (ETDEWEB)

    Palmucci, S., E-mail: spalmucci@sirm.org; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-15

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm{sup 2}/sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm{sup 2}/s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm{sup 2}/s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm{sup 2}/s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to

  2. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    International Nuclear Information System (INIS)

    Palmucci, S.; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-01

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm 2 /sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm 2 /s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm 2 /s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm 2 /s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to investigate better

  3. Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy

    International Nuclear Information System (INIS)

    Lahrsow, Maximilian; Albrecht, Moritz H.; Bickford, Matthew W.; Vogl, Thomas J.

    2017-01-01

    PurposeTo use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment.Materials and MethodsFifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions.ResultsOne month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10 −3  mm 2 /s) and no response (median 1.30 × 10 −3  mm 2 /s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC.ConclusionIn patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

  4. Predicting Treatment Response of Colorectal Cancer Liver Metastases to Conventional Lipiodol-Based Transarterial Chemoembolization Using Diffusion-Weighted MR Imaging: Value of Pretreatment Apparent Diffusion Coefficients (ADC) and ADC Changes Under Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lahrsow, Maximilian, E-mail: mlahrsow@gmail.com; Albrecht, Moritz H. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology (Germany); Bickford, Matthew W. [Medical University of South Carolina, Department of Radiology and Radiological Science (United States); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo use absolute pretreatment apparent diffusion coefficients (ADC) derived from diffusion-weighted MR imaging (DWI) to predict response to repetitive cTACE for unresectable liver metastases of colorectal carcinoma (CRLM) at 1 and 3 months after start of treatment.Materials and MethodsFifty-five metastases in 34 patients were examined with DWI prior to treatment and 1 month after initial cTACE. Treatment was performed in 4-week intervals. Response was evaluated at 1 and 3 months after start of therapy. Metastases showing a decrease of ≥30% in axial diameter were classified as responding lesions.ResultsOne month after initial cTACE, seven lesions showed early response. There was no significant difference in absolute pretreatment ADC values between responding and non-responding lesions (p = 0.94). Three months after initial cTACE, 17 metastases showed response. There was a significant difference (p = 0.021) between absolute pretreatment ADC values of lesions showing response (median 1.08 × 10{sup −3} mm{sup 2}/s) and no response (median 1.30 × 10{sup −3} mm{sup 2}/s). Pretreatment ADC showed fair diagnostic value to predict response (AUC 0.7). Lesions showing response at 3 months also revealed a significant increase in ADC between measurements before treatment and at one month after initial cTACE (p < 0.001). Applying an increase in ADC of 12.17%, response at 3 months after initial cTACE could be predicted with a sensitivity and specificity of 77 and 74%, respectively (AUC 0.817). Furthermore, there was a strong and significant correlation (r = 0.651, p < 0.001) between percentage change in size after third cTACE and percentage change in ADC.ConclusionIn patients with CRLM, ADC measurements are potential biomarkers for assessing response to cTACE.

  5. A Sigma-Delta ADC with Decimation and Gain Control Function for a Bluetooth Receiver in 130 nm Digital CMOS

    Directory of Open Access Journals (Sweden)

    Koh Jinseok

    2006-01-01

    Full Text Available We present a discrete-time second-order multibit sigma-delta ADC that filters and decimates by two the input data samples. At the same time it provides gain control function in its input sampling stage. A 4-tap FIR switched capacitor (SC architecture was chosen for antialiasing filtering. The decimation-by-two function is realized using divided-by-two clock signals in the antialiasing filter. Antialiasing, gain control, and sampling functions are merged in the sampling network using SC techniques. This compact architecture allows operating the preceding blocks at twice the ADC's clock frequency, thus improving the noise performance of the wireless receiver channel and relaxing settling requirements of the analog building blocks. The presented approach has been validated and incorporated in a commercial single-chip Bluetooth radio realized in a 1.5 V 130 nm digital CMOS process. The measured antialiasing filtering shows better than 75 dB suppression at the folding frequency band edge. A 67 dB dynamic range was measured with a sampling frequency of 37.5MHz.

  6. The IBL Readout System

    CERN Document Server

    Dopke, J; The ATLAS collaboration; Flick, T; Gabrielli, A; Kugel, A; Maettig, P; Morettini, P; Polini, A; Schroer, N

    2010-01-01

    The first upgrade for the ATLAS pixel detector will be an additional layer, which is called IBL (Insertable B-Layer). To readout this new layer having new electronics assembled an update of the readout electronics is necessary. The aim is to develop a system which is capable to read out at a higher bandwidth and also compatible with the existing system to be integrated into it. The talk will describe the necessary development to reach a new readout system, concentrating on the requirements of a newly designed Back of Crate card as the optical interface in the counting room.

  7. The IBL Readout System

    CERN Document Server

    Dopke, J; Flick, T; Gabrielli, A; Kugel, A; Maettig, P; Morettini, P; Polini, A; Schroer, N

    2011-01-01

    The first upgrade for the ATLAS Pixel Detector will be an additional layer, which is called IBL (Insertable B-Layer). To readout this new layer, having new electronics, an update of the readout electronics is necessary. The aim is to develop a system which is capable to read out at a higher bandwidth, but also compatible with the existing system to be integrated into it. This paper will describe the necessary development to reach a new readout system, concentrating on the requirements of a newly designed Back of Crate card as the optical interface in the counting room.

  8. Apparent Diffusion Coefficient (ADC) value: a potential imaging biomarker that reflects the biological features of rectal cancer.

    Science.gov (United States)

    Sun, Yiqun; Tong, Tong; Cai, Sanjun; Bi, Rui; Xin, Chao; Gu, Yajia

    2014-01-01

    We elected to analyze the correlation between the pre-treatment apparent diffusion coefficient (ADC) and the clinical, histological, and immunohistochemical status of rectal cancers. Forty-nine rectal cancer patients who received surgical resection without neoadjuvant therapy were selected that underwent primary MRI and diffusion-weighted imaging (DWI). Tumor ADC values were determined and analyzed to identify any correlations between these values and pre-treatment CEA or CA19-9 levels, and/or the histological and immunohistochemical properties of the tumor. Inter-observer agreement of confidence levels from two separate observers was suitable for ADC measurement (k  =  0.775). The pre-treatment ADC values of different T stage tumors were not equal (p  =  0.003). The overall trend was that higher T stage values correlated with lower ADC values. ADC values were also significantly lower for the following conditions: tumors with the presence of extranodal tumor deposits (p  =  0.006) and tumors with CA19-9 levels ≥ 35 g/ml (p  =  0.006). There was a negative correlation between Ki-67 LI and the ADC value (r  =  -0.318, p  =  0.026) and between the AgNOR count and the ADC value (r  =  -0.310, p  =  0.030). Significant correlations were found between the pre-treatment ADC values and T stage, extranodal tumor deposits, CA19-9 levels, Ki-67 LI, and AgNOR counts in our study. Lower ADC values were associated with more aggressive tumor behavior. Therefore, the ADC value may represent a useful biomarker for assessing the biological features and possible relationship to the status of identified rectal cancers.

  9. An 8 bit 1 MS/s SAR ADC with 7.72-ENOB

    Science.gov (United States)

    Duan, Jihai; Zhu, Zhiyong; Deng, Jinli; Xu, Weilin

    2017-08-01

    This paper presents a low power 8-bit 1 MS/s SAR ADC with 7.72-bit ENOB. Without an op-amp, an improved segmented capacitor DAC is proposed to reduce the capacitance and the chip area. A dynamic latch comparator with output offset voltage storage technology is used to improve the precision. Adding an extra positive feedback in the latch is to increase the speed. What is more, two pairs of CMOS switches are utilized to eliminate the kickback noise introduced by the latch. The proposed SAR ADC was fabricated in SMIC 0.18 {{μ }}{{m}} CMOS technology. The measured results show that this design achieves an SFDR of 61.8 dB and an ENOB of 7.72 bits, and it consumes 67.5 μW with the FOM of 312 fJ/conversion-step at 1 MS/s sample under 1.8 V power supply. Project supported by the National Natural Science Foundation of China (Nos. 61161003, 61264001, 61166004) and the Guangxi Key Laboratory of Precision Navigation Technology and Application Foundation (No. DH201501).

  10. ADC Histogram Analysis of Cervical Cancer Aids Detecting Lymphatic Metastases-a Preliminary Study.

    Science.gov (United States)

    Schob, Stefan; Meyer, Hans Jonas; Pazaitis, Nikolaos; Schramm, Dominik; Bremicker, Kristina; Exner, Marc; Höhn, Anne Kathrin; Garnov, Nikita; Surov, Alexey

    2017-12-01

    Apparent diffusion coefficient (ADC) histogram analysis has been used to some extent in cervical cancer (CC) to distinguish between low-grade and high-grade tumors. Although this differentiation is undoubtedly helpful, it would be even more crucial in the presurgical setting to determine whether a tumor already gained the potential to metastasize via the lymphatic system. So far, no studies investigated the potential of 3T ADC histogram analysis in CC to differentiate between nodal-positive and nodal-negative entities. Therefore, the principal aim of our study was to investigate the potential of 3T ADC histogram analysis to differentiate between CC with and without lymph node metastasis. The second aim was to elucidate possible differences in ADC histogram parameters between CC with limited vs. advanced tumor stages and well-differentiated vs. undifferentiated lesions. Finally, correlations of p53 expression and Ki-67 index with ADC parameters were analyzed. Eighteen female patients (mean age 55.4 years, range 32-79 years) with histopathologically confirmed cervical squamous cell carcinoma of the uterine cervix were prospectively enrolled. Tumor stages, tumor grading, status of metastatic dissemination, Ki67-index, and p53 expression were assessed in these patients. Diffusion weighted imaging (DWI) was obtained in a 3T scanner using the following b values: b0 and b1000 s/mm 2 . Group comparisons using Mann-Whitney U test revealed the following findings: nodal-positive CC had statistically significant lower ADC parameters (ADCmin, ADCmean, median ADC, Mode, p10, p25, p75, and p90) in comparison to nodal-negative CC (all p histogram analysis in 3T DWI. This information is crucial for the gynecological surgeon to identify the optimal treatment strategy for patients suffering from CC. Furthermore, ADCentropy was identified as a potential imaging biomarker for tumor heterogeneity and might be able to indicate further molecular changes like loss of p53 expression

  11. LHCb: Fast Readout Control for the upgraded readout architecture of the LHCb experiment at CERN

    CERN Multimedia

    Alessio, F

    2013-01-01

    The LHCb experiment at CERN has proposed an upgrade towards a full 40 MHz readout system in order to run between five and ten times its initial design luminosity with an upgraded LHCb detector. As a consequence, the various LHCb sub-systems in the readout architecture will be upgraded to cope with higher sub-detector occupancies, higher rate, and higher readout load. The new architecture, new functionalities, and the first hardware implementation of a new LHCb Readout Control system (commonly referred to as S-TFC) for the upgraded LHCb experiment is here presented. Our attention is focused in describing solutions for the distribution of clock and timing information to control the entire upgraded readout architecture by profiting of a bidirectional optical network and powerful FPGAs, including a real-time mechanism to synchronize the entire system. Solutions and implementations are presented, together with first results on the simulation and the validation of the system.

  12. Readout ASIC for ILC-FPCCD vertex detector

    International Nuclear Information System (INIS)

    Takubo, Yosuke; Miyamoto, Akiya; Ikeda, Hirokazu; Yamamoto, Hitoshi; Itagaki, Kennosuke; Nagamine, Tadashi; Sugimoto, Yasuhiro

    2010-01-01

    The concept of FPCCD (Fine Pixel CCD) whose pixel size is 5x5μm 2 has been proposed as vertex detector at ILC. Since FPCCD has 128 x20,000 pixels in one readout channel, its readout poses a considerable challenge. We have developed a prototype of readout ASIC to readout the large number of pixels during the inter-train gap of the ILC beam. In this paper, we report the design and performance of the readout ASIC.

  13. A high speed, selective multi-ADC to computer data transfer interface, for nuclear physics experiments

    International Nuclear Information System (INIS)

    Arctaedius, T.; Ekstroem, R.E.

    1986-08-01

    A link connecting up to fifteen Analog to Digital Converters with a computer, through a Direct Memory Access interface, is described. The interface decides which of the connected ADC:s that participate in an event, and transfers the output-data from these to the computer, accompanied with a 2-byte word identifying the participating ADC:s. This data format can be recorded on tape without further transformations, and is easy to unfold at the off-line analysis. Data transfer is accomplished in less than a few microseconds, which is made possible by the use of high speed TTL circuits. (authors)

  14. Fast ADC interface with data reduction facilities for multi-parameter experiments in nuclear physics

    Energy Technology Data Exchange (ETDEWEB)

    Liebl, W; Franz, N; Ziegler, G [Technische Univ. Muenchen, Garching (Germany, F.R.). Fakultaet Physik; Hegewisch, S; Kunz, D; Maier, D; Lutter, R; Schoeffel, K; Stanzel, B [Muenchen Univ. (Germany, F.R.). Sektion Physik; Drescher, B [Hahn-Meitner-Institut fuer Kernforschung Berlin G.m.b.H. (Germany, F.R.)

    1982-03-01

    A modular ADC interface system for multi-parameter experiments with single NIM ADCs is described. 16 fast ADCs are handled by CAMAC modules and data buses in order to build up a sophisticated hardware system which is able to take coincidence data and singles spectra in parallel. The coincidence logic is handled by one of the interface modules; the interface allows online data reduction. The further expansion of the system will be discussed.

  15. An 11-bit 200 MS/s subrange SAR ADC with low-cost integrated reference buffer

    Science.gov (United States)

    He, Xiuju; Gu, Xian; Li, Weitao; Jiang, Hanjun; Li, Fule; Wang, Zhihua

    2017-10-01

    This paper presents an 11-bit 200 MS/s subrange SAR ADC with an integrated reference buffer in 65 nm CMOS. The proposed ADC employs a 3.5-bit flash ADC for coarse conversion, and a compact timing scheme at the flash/SAR boundary to speed up the conversion. The flash decision is used to control charge compensating for the reference voltage to reduce its input-dependent fluctuation. Measurement results show that the fabricated ADC has achieved significant improvement by applying the reference charge compensation. In addition, the ADC achieves a maximum signal-to-noise-and-distortion ratio of 59.3 dB at 200 MS/s. It consumes 3.91 mW from a 1.2 V supply, including the reference buffer. Project supported by the Zhongxing Telecommunication Equipment Corporation and Beijing Microelectronics Technology Institute.

  16. Apparent Diffusion Coefficient (ADC value: a potential imaging biomarker that reflects the biological features of rectal cancer.

    Directory of Open Access Journals (Sweden)

    Yiqun Sun

    Full Text Available OBJECTIVE: We elected to analyze the correlation between the pre-treatment apparent diffusion coefficient (ADC and the clinical, histological, and immunohistochemical status of rectal cancers. MATERIALS AND METHODS: Forty-nine rectal cancer patients who received surgical resection without neoadjuvant therapy were selected that underwent primary MRI and diffusion-weighted imaging (DWI. Tumor ADC values were determined and analyzed to identify any correlations between these values and pre-treatment CEA or CA19-9 levels, and/or the histological and immunohistochemical properties of the tumor. RESULTS: Inter-observer agreement of confidence levels from two separate observers was suitable for ADC measurement (k  =  0.775. The pre-treatment ADC values of different T stage tumors were not equal (p  =  0.003. The overall trend was that higher T stage values correlated with lower ADC values. ADC values were also significantly lower for the following conditions: tumors with the presence of extranodal tumor deposits (p  =  0.006 and tumors with CA19-9 levels ≥ 35 g/ml (p  =  0.006. There was a negative correlation between Ki-67 LI and the ADC value (r  =  -0.318, p  =  0.026 and between the AgNOR count and the ADC value (r  =  -0.310, p  =  0.030. CONCLUSION: Significant correlations were found between the pre-treatment ADC values and T stage, extranodal tumor deposits, CA19-9 levels, Ki-67 LI, and AgNOR counts in our study. Lower ADC values were associated with more aggressive tumor behavior. Therefore, the ADC value may represent a useful biomarker for assessing the biological features and possible relationship to the status of identified rectal cancers.

  17. An optical fiber-based flexible readout system for micro-pattern gas detectors

    Science.gov (United States)

    Li, C.; Feng, C. Q.; Zhu, D. Y.; Liu, S. B.; An, Q.

    2018-04-01

    This paper presents an optical fiber-based readout system that is intended to provide a general purpose multi-channel readout solution for various Micro-Pattern Gas Detectors (MPGDs). The proposed readout system is composed of several front-end cards (FECs) and a data collection module (DCM). The FEC exploits the capability of an existing 64-channel generic TPC readout ASIC chip, named AGET, to implement 256 channels readout. AGET offers FEC a large flexibility in gain range (4 options from 120 fC to 10 pC), peaking time (16 options from 50 ns to 1 us) and sampling freqency (100 MHz max.). The DCM contains multiple 1 Gbps optical fiber serial link interfaces that allow the system scaling up to 1536 channels with 6 FECs and 1 DCM. Further scaling up is possible through cascading of multiple DCMs, by configuring one DCM as a master while other DCMs in slave mode. This design offers a rapid readout solution for different application senario. Tests indicate that the nonlinearity of each channel is less than 1%, and the equivalent input noise charge is typically around 0.7 fC in RMS (root mean square), with a noise slope of about 0.01 fC/pF. The system level trigger rate limit is about 700 Hz in all channel readout mode. When in hit channel readout mode, supposing that typically 10 percent of channels are fired, trigger rate can go up to about 7 kHz. This system has been tested with Micromegas detector and GEM detector, confirming its capability in MPGD readout. Details of hardware and FPGA firmware design, as well as system performances, are described in the paper.

  18. A low-voltage low-power 10-bit 200 MS/s pipelined ADC in 90 nm CMOS

    NARCIS (Netherlands)

    Abdinia, S.; Yavari, M.

    2010-01-01

    This paper presents a low-power 10-bit 200 MS/s pipelined ADC in a 90 nm CMOS technology with 1 V supply voltage. To decrease the power dissipation efficiently, a new architecture using a combination of two power reduction techniques named double-sampling and opamp-sharing has been used to reduce

  19. Dual-readout calorimetry with scintillating crystals

    International Nuclear Information System (INIS)

    Pinci, D

    2009-01-01

    The dual-readout approach, which allows an event-by-event measurement of the electromagnetic shower fraction, was originally demonstrated with the DREAM sampling calorimeter. This approach can be extended to homogeneous detectors like crystals if Cherenkov and scintillation light can be separated. In this paper we present several methods we developed for distinguishing the two components in PWO and BGO based calorimeters and the results obtained.

  20. A continuous-time/discrete-time mixed audio-band sigma delta ADC

    International Nuclear Information System (INIS)

    Liu Yan; Hua Siliang; Wang Donghui; Hou Chaohuan

    2011-01-01

    This paper introduces a mixed continuous-time/discrete-time, single-loop, fourth-order, 4-bit audio-band sigma delta ADC that combines the benefits of continuous-time and discrete-time circuits, while mitigating the challenges associated with continuous-time design. Measurement results show that the peak SNR of this ADC reaches 100 dB and the total power consumption is less than 30 mW. (semiconductor integrated circuits)

  1. Diffusion-weighted imaging of breast lesions: Region-of-interest placement and different ADC parameters influence apparent diffusion coefficient values

    Energy Technology Data Exchange (ETDEWEB)

    Bickel, Hubert; Pinker, Katja; Polanec, Stephan; Magometschnigg, Heinrich; Wengert, Georg; Spick, Claudio; Helbich, Thomas H.; Baltzer, Pascal [Medical University Vienna, Division of Molecular and Gender Imaging, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Bogner, Wolfgang [Medical University Vienna - MR Center of Excellence, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Bago-Horvath, Zsuzsanna [Medical University Vienna, Department of Pathology, Vienna (Austria)

    2017-05-15

    To investigate the influence of region-of-interest (ROI) placement and different apparent diffusion coefficient (ADC) parameters on ADC values, diagnostic performance, reproducibility and measurement time in breast tumours. In this IRB-approved, retrospective study, 149 histopathologically proven breast tumours (109 malignant, 40 benign) in 147 women (mean age 53.2) were investigated. Three radiologists independently measured minimum, mean and maximum ADC, each using three ROI placement approaches:1 - small 2D-ROI, 2 - large 2D-ROI and 3 - 3D-ROI covering the whole lesion. One reader performed all measurements twice. Median ADC values, diagnostic performance, reproducibility, and measurement time were calculated and compared between all combinations of ROI placement approaches and ADC parameters. Median ADC values differed significantly between the ROI placement approaches (p <.001). Minimum ADC showed the best diagnostic performance (AUC.928-.956), followed by mean ADC obtained from 2D ROIs (.926-.94). Minimum and mean ADC showed high intra- (ICC.85-.94) and inter-reader reproducibility (ICC.74-.94). Median measurement time was significantly shorter for the 2D ROIs (p <.001). ROI placement significantly influences ADC values measured in breast tumours. Minimum and mean ADC acquired from 2D-ROIs are useful for the differentiation of benign and malignant breast lesions, and are highly reproducible, with rapid measurement. (orig.)

  2. Development of a Timepix3 readout system based on the Merlin readout system

    International Nuclear Information System (INIS)

    Crevatin, G.; Carrato, S.; Horswell, I.; Omar, D.; Tartoni, N.; Cautero, G.

    2015-01-01

    Timepix3 chip is a new ASIC specifically designed to readout hybrid pixel detectors. The main purpose of Timepix3 is to measure the time of arrival of events. This characteristic can be exploited very effectively to develop detectors for time resolved experiments at synchrotron radiation facilities. In order to investigate how the ASIC can be applied to synchrotron experiments the Merlin readout system, developed at Diamond for the Medipix3 ASIC, has been adapted to readout the Timepix3 ASIC. The first tests of the ASIC with pulse injection and with alpha particles show that its behaviour is consistent with its nominal characteristics

  3. A custom floating point format ADC for LHC calorimetry

    International Nuclear Information System (INIS)

    Hermel, V.; Lecoq, J.; Bohner, G.

    1996-01-01

    Due to their large dynamic range (in excess of 16 bits) signals from LHC calorimetry poses severe problems to the shaping and digitizing circuits. We are investigating a solution for an ADC based on a custom floating point format. Since the calorimeter precision is limited, the full dynamic range can be split into 8 positive sub-ranges and 5 negative ones, each with an 8 bits dynamic. The reduced number of bits (8 for the mantissa, 4 for the exponent and 1 for the sign) translates itself into a reduction of the power consumption both of the ADC and of the following digital filtering stages. (authors)

  4. Differentiation of orbital lymphoma and idiopathic orbital inflammatory pseudotumor: combined diagnostic value of conventional MRI and histogram analysis of ADC maps.

    Science.gov (United States)

    Ren, Jiliang; Yuan, Ying; Wu, Yingwei; Tao, Xiaofeng

    2018-05-02

    The overlap of morphological feature and mean ADC value restricted clinical application of MRI in the differential diagnosis of orbital lymphoma and idiopathic orbital inflammatory pseudotumor (IOIP). In this paper, we aimed to retrospectively evaluate the combined diagnostic value of conventional magnetic resonance imaging (MRI) and whole-tumor histogram analysis of apparent diffusion coefficient (ADC) maps in the differentiation of the two lesions. In total, 18 patients with orbital lymphoma and 22 patients with IOIP were included, who underwent both conventional MRI and diffusion weighted imaging before treatment. Conventional MRI features and histogram parameters derived from ADC maps, including mean ADC (ADC mean ), median ADC (ADC median ), skewness, kurtosis, 10th, 25th, 75th and 90th percentiles of ADC (ADC 10 , ADC 25 , ADC 75 , ADC 90 ) were evaluated and compared between orbital lymphoma and IOIP. Multivariate logistic regression analysis was used to identify the most valuable variables for discriminating. Differential model was built upon the selected variables and receiver operating characteristic (ROC) analysis was also performed to determine the differential ability of the model. Multivariate logistic regression showed ADC 10 (P = 0.023) and involvement of orbit preseptal space (P = 0.029) were the most promising indexes in the discrimination of orbital lymphoma and IOIP. The logistic model defined by ADC 10 and involvement of orbit preseptal space was built, which achieved an AUC of 0.939, with sensitivity of 77.30% and specificity of 94.40%. Conventional MRI feature of involvement of orbit preseptal space and ADC histogram parameter of ADC 10 are valuable in differential diagnosis of orbital lymphoma and IOIP.

  5. A FASTBUS flash ADC system for the Mark II vertex chamber

    International Nuclear Information System (INIS)

    Barker, L.

    1988-10-01

    This is a description of a flash ADC system built for the Mark II experiment at the Stanford Linear Accelerator Center (SLAC). This system was designed for use in the experiment's vertex chamber where signals could occur over a relatively long time, approximately 10 microseconds. This long time, coupled with fast cable amplifiers, necessitated an alternate design approach than was used with a dE/dX FASTBUS flash ADC design. 1 ref., 6 figs

  6. The BGO Calorimeter of BGO-OD Experiment

    International Nuclear Information System (INIS)

    Bantes, B; Bayadilov, D; Bella, A; Bielefeldt, P; Bieling, J; Bleckwenn, M; Dutz, H; Elsner, D; Freyermuth, O; Beck, R; Becker, M; Böse, S; Braghieri, A; Brinkmann, K-Th; Friedrich, S; Burdeynyi, D; Curciarello, F; Leo, V De; Salvo, R Di; Fantini, A

    2015-01-01

    The BGO Rugby Ball is a large solid angle electromagnetic calorimeter now installed in the ELSA Facility in Bonn. The BGO is operating in the BGO-OD experiment aiming to study meson photoproduction off proton and neutron induced by a Bremsstrahlung polarized gamma beam of energies from 0.2 to 3.2 GeV and an intensity of 5 × 10 7 photons per second. The scintillating material characteristics and the photomultiplier read-out make this detector particularly suited for the detection of medium energy photons and electrons with very good energy resolution. The detector has been equipped with a new electronics read-out system, consisting of 30 sampling ADC Wie-Ne-R modules which perform the off-line reconstruction of the signal start-time allowing for a good timing resolution. Performances in linearity, resolution and time response have been carefully tested at the Beam Test Facility of the INFN National Laboratories in Frascati by using a matrix of 7 BGO crystals coupled to photomultipliers and equipped with the Wie-Ne-R sampling ADCs

  7. Design of a hysteretic SQUID as the readout for a dc SQUID

    International Nuclear Information System (INIS)

    Gershenson, M.

    1991-01-01

    This paper present a design for an optimal hysteretic SQUID readout circuit for a DC SQUID, thus eliminating the need for bulky output transformers or resonance matching circuits. The hysteretic readout system, which is based in part on standard sampling theory, is compared to another similar system and shown to be superior in terms of slew rate and immunity of electromagnetic interference. The circuit will be useful in optimizing the performance of biomagnetic systems

  8. Increasing the Accuracy of Volume and ADC Delineation for Heterogeneous Tumor on Diffusion-Weighted MRI: Correlation with PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Nan-Jie [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Wong, Chun-Sing, E-mail: drcswong@gmail.com [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Chu, Yiu-Ching [Department of Radiology, Kwong Wah Hospital, Hong Kong (China); Guo, Hua [Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing (China); Huang, Bingsheng [Department of Diagnostic Radiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong (China); Chan, Queenie [Philips Healthcare, Hong Kong (China)

    2013-10-01

    Purpose: To improve the accuracy of volume and apparent diffusion coefficient (ADC) measurements in diffusion-weighted magnetic resonance imaging (MRI), we proposed a method based on thresholding both the b0 images and the ADC maps. Methods and Materials: In 21 heterogeneous lesions from patients with metastatic gastrointestinal stromal tumors (GIST), gross lesion were manually contoured, and corresponding volumes and ADCs were denoted as gross tumor volume (GTV) and gross ADC (ADC{sub g}), respectively. Using a k-means clustering algorithm, the probable high-cellularity tumor tissues were selected based on b0 images and ADC maps. ADC and volume of the tissues selected using the proposed method were denoted as thresholded ADC (ADC{sub thr}) and high-cellularity tumor volume (HCTV), respectively. The metabolic tumor volume (MTV) in positron emission tomography (PET)/computed tomography (CT) was measured using 40% maximum standard uptake value (SUV{sub max}) as the lower threshold, and corresponding mean SUV (SUV{sub mean}) was also measured. Results: HCTV had excellent concordance with MTV according to Pearson's correlation (r=0.984, P<.001) and linear regression (slope = 1.085, intercept = −4.731). In contrast, GTV overestimated the volume and differed significantly from MTV (P=.005). ADC{sub thr} correlated significantly and strongly with SUV{sub mean} (r=−0.807, P<.001) and SUV{sub max} (r=−0.843, P<.001); both were stronger than those of ADC{sub g}. Conclusions: The proposed lesion-adaptive semiautomatic method can help segment high-cellularity tissues that match hypermetabolic tissues in PET/CT and enables more accurate volume and ADC delineation on diffusion-weighted MR images of GIST.

  9. Performance of the CAMEX64 silicon strip readout chip

    International Nuclear Information System (INIS)

    Yarema, R.J.

    1989-06-01

    The CAMEX64 is a 64 channel full custom CMOS chip designed specifically for the readout of silicon strip detectors. CAMEX which stands for CMOS Multichannel Analog MultiplEXer for Silicon Strip Detectors was designed by members of the Franhofer Institute for Microelectronic Circuits and Systems and the Max Planck Institute for Physics and Astrophysics. Each CAMEX channel has a switched capacitor charge sensitive amplifier with 4 sampling capacitors and a multiplexing scheme for reading out each of the channels on an analog bus. The device uses multiple sampling capacitors to filter and reduce input noise. Filtering is controlled through sampling techniques using external clocks. The device operates in a double correlated sampling mode and therefore cannot separate detector leakage current from a charge input. Normal operation of this device is similar to all other silicon readout chips designed and built thus far in that there is a data acquisition cycle during which charge is simultaneously accepted on all channels for a short period of time from a detector array, followed by a readout cycle where that charge or hit information is read out. This device works especially well for colliding beam experiments where the time of charge arrival is accurately known. However it can be used in fixed target or asynchronous mode where the time of charge arrival is not well known. In the asynchronous mode it appears that gain is somewhat dependent on the time interval required to decide whether or not to accept charge input information and thus the maximum signal to noise performance found with the synchronous mode may not be achieved in the asynchronous mode. 18 figs., 5 tabs

  10. DW-MRI of liver lesions: Can a single ADC-value represent the entire lesion?

    International Nuclear Information System (INIS)

    Schmid-Tannwald, C.; Dahi, F.; Jiang, Y.; Ivancevic, M.K.; Rist, C.; Sethi, I.; Oommen, J.; Oto, A.

    2014-01-01

    Aim: To evaluate whether focal liver lesions (FLLs) exhibit a homogeneous appearance on apparent diffusion coefficient (ADC) maps and whether there is inter-section variation in the calculated ADC values of FLLs (inter-section range). Materials and methods: Eighty-eight patients with 128 FLLs (70 benign, 58 malignant) who underwent abdominal magnetic resonance imaging (MRI) including diffusion-weighted (DW)-MRI were included. Two observers evaluated variation of signal intensity of each FLL within each ADC map image (intra-section) and among different ADC map images through the lesion (inter-section). ADC values of each FLL and neighbouring liver parenchyma were measured on all sections. The inter-section range of FLLs was compared with the neighbouring liver parenchyma. Results: Intra-section inhomogeneity was noted in 39.8% (97/244 sections) and 38.9% (95/244) of benign lesions, and 61% (114/187 sections) and 61.5% (115/187) of malignant lesions, by observer 1 and observer 2, respectively. Inter-section inhomogeneity was noted in 25.7% (18/70) and 27.1% (19/70) of benign lesions, and 51.7% (30/58) and 50% (29/58) of malignant lesions, by observer 1 and observer 2, respectively. The inter-section range for both benign (0.28 × 10 −3  mm²/s) and malignant (0.25 × 10 −3  mm²/s) FLLs were significantly greater than that of liver parenchyma surrounding benign (0.16 × 10 −3  mm²/s, p < 0.001) and malignant (0.14 × 10 −3  mm²/s, p = 0.01) FLLs. Conclusion: Due to intra-/inter-section variations in ADC values of benign and malignant FLLs, a single ADC value may not reliably represent the entire lesion

  11. Volterra Filtering for ADC Error Correction

    Directory of Open Access Journals (Sweden)

    J. Saliga

    2001-09-01

    Full Text Available Dynamic non-linearity of analog-to-digital converters (ADCcontributes significantly to the distortion of digitized signals. Thispaper introduces a new effective method for compensation such adistortion based on application of Volterra filtering. Considering ana-priori error model of ADC allows finding an efficient inverseVolterra model for error correction. Efficiency of proposed method isdemonstrated on experimental results.

  12. A fast ADC interface with data reduction facilities for multi-parameter experiments in nuclear physics

    International Nuclear Information System (INIS)

    Liebl, W.; Franz, N.; Ziegler, G.

    1982-01-01

    A modular ADC interface system for multi-parameter experiments with single NIM ADCs is described. 16 fast ADCs are handled by CAMAC modules and data buses in order to build up a sophisticated hardware system which is able to take coincidence data and singles spectra in parallel. The coincidence logic is handled by one of the interface modules; the interface allows online data reduction. The further expansion of the system will be discussed. (orig.)

  13. A FASTBUS flash ADC system for the Mark II vertex chamber

    Energy Technology Data Exchange (ETDEWEB)

    Barker, L.

    1988-10-01

    This is a description of a flash ADC system built for the Mark II experiment at the Stanford Linear Accelerator Center (SLAC). This system was designed for use in the experiment's vertex chamber where signals could occur over a relatively long time, approximately 10 microseconds. This long time, coupled with fast cable amplifiers, necessitated an alternate design approach than was used with a dE/dX FASTBUS flash ADC design. 1 ref., 6 figs.

  14. Single-Readout High-Density Memristor Crossbar

    KAUST Repository

    Zidan, M. A.

    2016-01-07

    High-density memristor-crossbar architecture is a very promising technology for future computing systems. The simplicity of the gateless-crossbar structure is both its principal advantage and the source of undesired sneak-paths of current. This parasitic current could consume an enormous amount of energy and ruin the readout process. We introduce new adaptive-threshold readout techniques that utilize the locality and hierarchy properties of the computer-memory system to address the sneak-paths problem. The proposed methods require a single memory access per pixel for an array readout. Besides, the memristive crossbar consumes an order of magnitude less power than state-of-the-art readout techniques.

  15. Single-Readout High-Density Memristor Crossbar

    KAUST Repository

    Zidan, M. A.; Omran, Hesham; Naous, Rawan; Salem, Ahmed Sultan; Fahmy, H. A. H.; Lu, W. D.; Salama, Khaled N.

    2016-01-01

    High-density memristor-crossbar architecture is a very promising technology for future computing systems. The simplicity of the gateless-crossbar structure is both its principal advantage and the source of undesired sneak-paths of current. This parasitic current could consume an enormous amount of energy and ruin the readout process. We introduce new adaptive-threshold readout techniques that utilize the locality and hierarchy properties of the computer-memory system to address the sneak-paths problem. The proposed methods require a single memory access per pixel for an array readout. Besides, the memristive crossbar consumes an order of magnitude less power than state-of-the-art readout techniques.

  16. HVM die yield improvement as a function of DRSEM ADC

    Science.gov (United States)

    Maheshwary, Sonu; Haas, Terry; McGarvey, Steve

    2010-03-01

    Given the current manufacturing technology roadmap and the competitiveness of the global semiconductor manufacturing environment in conjunction with the semiconductor manufacturing market dynamics, the market place continues to demand a reduced die manufacturing cost. This continuous pressure on lowering die cost in turn drives an aggressive yield learning curve, a key component of which is defect reduction of manufacturing induced anomalies. In order to meet and even exceed line and die yield targets there is a need to revamp defect classification strategies and place a greater emphasize on increasing the accuracy and purity of the Defect Review Scanning Electron Microscope (DRSEM) Automated Defect Classification (ADC) results while placing less emphasis on the ADC results of patterned/un-patterned wafer inspection systems. The increased emphasis on DRSEM ADC results allows for a high degree of automation and consistency in the classification data and eliminates variance induced by the manufacturing staff. This paper examines the use of SEM based Auto Defect Classification in a high volume manufacturing environment as a key driver in the reduction of defect limited yields.

  17. A 10 bit 200 MS/s pipeline ADC using loading-balanced architecture in 0.18 μm CMOS

    Science.gov (United States)

    Wang, Linfeng; Meng, Qiao; Zhi, Hao; Li, Fei

    2017-07-01

    A new loading-balanced architecture for high speed and low power consumption pipeline analog-to-digital converter (ADC) is presented in this paper. The proposed ADC uses SHA-less, op-amp and capacitor-sharing technique, capacitor-scaling scheme to reduce the die area and power consumption. A new capacitor-sharing scheme was proposed to cancel the extra reset phase of the feedback capacitors. The non-standard inter-stage gain increases the feedback factor of the first stage and makes it equal to the second stage, by which, the load capacitor of op-amp shared by the first and second stages is balanced. As for the fourth stage, the capacitor and op-amp no longer scale down. From the system’s point of view, all load capacitors of the shared OTAs are balanced by employing a loading-balanced architecture. The die area and power consumption are optimized maximally. The ADC is implemented in a 0.18 μm 1P6M CMOS technology, and occupies a die area of 1.2 × 1.2 mm{}2. The measurement results show a 55.58 dB signal-to-noise-and-distortion ratio (SNDR) and 62.97 dB spurious-free dynamic range (SFDR) with a 25 MHz input operating at a 200 MS/s sampling rate. The proposed ADC consumes 115 mW at 200 MS/s from a 1.8 V supply.

  18. ITS Temperature Monitoring

    CERN Document Server

    Savin, A E; CERN. Geneva; Gerasimov, S F

    1999-01-01

    The results of the R&D done under the ISTC#345 grant are presented for consideration for possible future application. The choice of the temperature sensors is described. Thin-film miniature Pt-sensors were produced and the results of the metrological studies of the manufactured samples are presented. The multi-channel temperature data readout system prototype and results of long-term stability tests are discussed. List of figures: Figure 1 Thin film Pt-thermometer topology Figure 2 Studies of long-term stability of Pt-thermometers Figure 3 DT structural scheme Figures 4 & 5 Output data ADC read operation, Control register ADC write operation

  19. Performance of MSGC with analog pipeline readout

    International Nuclear Information System (INIS)

    Gomez, F.; Adeva, B.; Gracia, G.; Lopez, M.A.; Nunez, T.; Pazos, A.; Plo, M.; Rodriguez, A.; Santamarina, C.; Vazquez, P.

    1997-01-01

    We analyse some of the performance characteristics of a chromium MSGC operated with Ar-DME 50%-50% in a test beam at CERN. Excellent signal-to-noise ratio and efficiency has been achieved with this gas mixture using cathode analog pipeline readout. We also determine optimal parameters for the sampling algorithm in order to work in a random trigger experiment (fixed target). (orig.)

  20. Diagnostic value of diffusion weighted MRI and ADC in differential diagnosis of cavernous hemangioma of the liver.

    Science.gov (United States)

    Tokgoz, Ozlem; Unlu, Ebru; Unal, Ilker; Serifoglu, Ismail; Oz, Ilker; Aktas, Elif; Caglar, Emrah

    2016-03-01

    To investigate the use of diffusion weighted magnetic resonance imaging (DWI) and the apparent diffusion coefficient (ADC) values in the diagnosis of hemangioma. The study population consisted of 72 patients with liver masses larger than 1 cm (72 focal lesions). DWI examination with a b value of 600 s/mm2 was carried out for all patients. After DWI examination, an ADC map was created and ADC values were measured for 72 liver masses and normal liver tissue (control group). The average ADC values of normal liver tissue and focal liver lesions, the "cut-off" ADC values, and the diagnostic sensitivity and specificity of the ADC map in diagnosing hemangioma, benign and malignant lesions were researched. Of the 72 liver masses, 51 were benign and 21 were malignant. Benign lesions comprised 38 hemangiomas and 13 simple cysts. Malignant lesions comprised 9 hepatocellular carcinomas, and 12 metastases. The highest ADC values were measured for cysts (3.782±0.53×10(-3) mm(2)/s) and hemangiomas (2.705±0.63×10(-3) mm(2)/s). The average ADC value of hemangiomas was significantly higher than malignant lesions and the normal control group (p<0.001). The average ADC value of cysts were significantly higher when compared to hemangiomas and normal control group (p<0.001). To distinguish hemangiomas from malignant liver lesions, the "cut-off" ADC value of 1.800×10(-3) mm(2)/s had a sensitivity of 97.4% and a specificity of 90.9%. To distinguish hemangioma from normal liver parenchyma the "cut-off" value of 1.858×10(-3) mm(2)/s had a sensitivity of 97.4% and a specificity of 95.7%. To distinguish benign liver lesions from malignant liver lesions the "cut-off" value of 1.800×10(-3) mm(2)/s had a sensitivity of 96.1% and a specificity of 90.0%. DWI and quantitative measurement of ADC values can be used in differential diagnosis of benign and malignant liver lesions and also in the diagnosis and differentiation of hemangiomas. When dynamic examination cannot distinguish cases with

  1. Generation and Analysis of Constrained Random Sampling Patterns

    DEFF Research Database (Denmark)

    Pierzchlewski, Jacek; Arildsen, Thomas

    2016-01-01

    Random sampling is a technique for signal acquisition which is gaining popularity in practical signal processing systems. Nowadays, event-driven analog-to-digital converters make random sampling feasible in practical applications. A process of random sampling is defined by a sampling pattern, which...... indicates signal sampling points in time. Practical random sampling patterns are constrained by ADC characteristics and application requirements. In this paper, we introduce statistical methods which evaluate random sampling pattern generators with emphasis on practical applications. Furthermore, we propose...... algorithm generates random sampling patterns dedicated for event-driven-ADCs better than existed sampling pattern generators. Finally, implementation issues of random sampling patterns are discussed....

  2. ADC common noise correction and zero suppression in the PIBETA detector

    International Nuclear Information System (INIS)

    Frlez, E.; Pocanic, D.; Ritt, S.

    2001-01-01

    We describe a simple procedure for reducing Analog-to-Digital Converter (ADC) common noise in modular detectors that does not require additional hardware. A method using detector noise groups should work well for modular particle detectors such as segmented electromagnetic calorimeters, plastic scintillator hodoscopes, cathode strip wire chambers, segmented active targets, and the like. We demonstrate a 'second pedestal noise correction' method by comparing representative ADC pedestal spectra for various elements of the PIBETA detector before and after the applied correction

  3. Digital readout alpha survey instrument

    International Nuclear Information System (INIS)

    Jacobs, M.E.

    1976-01-01

    A prototype solid-state digital readout alpha particle survey instrument has been designed and constructed. The meter incorporates a Ludlum alpha scintillator as a detector, digital logic circuits for control and timing, and a Digilin counting module with reflective liquid crystal display. The device is used to monitor alpha radiation from a surface. Sample counts are totalized over 10-second intervals and displayed digitally in counts per minute up to 19,999. Tests over source samples with counts to 15,600 cpm have shown the device to be rapid, versatile and accurate. The instrument can be fabricated in one man-week and requires about $835 in material costs. A complete set of drawings is included

  4. Triggerless Readout with Time and Amplitude Reconstruction of Event Based on Deconvolution Algorithm

    International Nuclear Information System (INIS)

    Kulis, S.; Idzik, M.

    2011-01-01

    In future linear colliders like CLIC, where the period between the bunch crossings is in a sub-nanoseconds range ( 500 ps), an appropriate detection technique with triggerless signal processing is needed. In this work we discuss a technique, based on deconvolution algorithm, suitable for time and amplitude reconstruction of an event. In the implemented method the output of a relatively slow shaper (many bunch crossing periods) is sampled and digitalised in an ADC and then the deconvolution procedure is applied to digital data. The time of an event can be found with a precision of few percent of sampling time. The signal to noise ratio is only slightly decreased after passing through the deconvolution filter. The performed theoretical and Monte Carlo studies are confirmed by the results of preliminary measurements obtained with the dedicated system comprising of radiation source, silicon sensor, front-end electronics, ADC and further digital processing implemented on a PC computer. (author)

  5. First functionality tests of a 64 × 64 pixel DSSC sensor module connected to the complete ladder readout

    Science.gov (United States)

    Donato, M.; Hansen, K.; Kalavakuru, P.; Kirchgessner, M.; Kuster, M.; Porro, M.; Reckleben, C.; Turcato, M.

    2017-03-01

    The European X-ray Free Electron Laser (XFEL.EU) will provide every 0.1 s a train of 2700 spatially coherent ultrashort X-ray pulses at 4.5 MHz repetition rate. The Small Quantum Systems (SQS) instrument and the Spectroscopy and Coherent Scattering instrument (SCS) operate with soft X-rays between 0.5 keV-6 keV. The DEPFET Sensor with Signal Compression (DSSC) detector is being developed to meet the requirements set by these two XFEL.EU instruments. The DSSC imager is a 1 mega-pixel camera able to store up to 800 single-pulse images per train. The so-called ladder is the basic unit of the DSSC detector. It is the single unit out of sixteen identical-units composing the DSSC-megapixel camera, containing all representative electronic components of the full-size system and allows testing the full electronic chain. Each DSSC ladder has a focal plane sensor with 128× 512 pixels. The read-out ASIC provides full-parallel readout of the sensor pixels. Every read-out channel contains an amplifier and an analog filter, an up-to 9 bit ADC and the digital memory. The ASIC amplifier have a double front-end to allow one to use either DEPFET sensors or Mini-SDD sensors. In the first case, the signal compression is a characteristic intrinsic of the sensor; in the second case, the compression is implemented at the first amplification stage. The goal of signal compression is to meet the requirement of single-photon detection capability and wide dynamic range. We present the first results of measurements obtained using a 64× 64 pixel DEPFET sensor attached to the full final electronic and data-acquisition chain.

  6. Digital column readout architectures for hybrid pixel detector readout chips

    International Nuclear Information System (INIS)

    Poikela, T; Plosila, J; Westerlund, T; Buytaert, J; Campbell, M; Gaspari, M De; Llopart, X; Wyllie, K; Gromov, V; Kluit, R; Beuzekom, M van; Zappon, F; Zivkovic, V; Brezina, C; Desch, K; Fu, Y; Kruth, A

    2014-01-01

    In this paper, two digital column architectures suitable for sparse readout of data from a pixel matrix in trigger-less applications are presented. Each architecture reads out a pixel matrix of 256 x 256 pixels with a pixel pitch of 55 μm. The first architecture has been implemented in the Timepix3 chip, and this is presented together with initial measurements. Simulation results and measured data are compared. The second architecture has been designed for Velopix, a readout chip planned for the LHCb VELO upgrade. Unlike Timepix3, this has to be tolerant to radiation-induced single-event effects. Results from post-layout simulations are shown with the circuit architectures

  7. Frequency multiplexing for readout of spin qubits

    Energy Technology Data Exchange (ETDEWEB)

    Hornibrook, J. M.; Colless, J. I.; Mahoney, A. C.; Croot, X. G.; Blanvillain, S.; Reilly, D. J., E-mail: david.reilly@sydney.edu.au [ARC Centre of Excellence for Engineered Quantum Systems, School of Physics, University of Sydney, Sydney, NSW 2006 (Australia); Lu, H.; Gossard, A. C. [Materials Department, University of California, Santa Barbara, California 93106 (United States)

    2014-03-10

    We demonstrate a low loss, chip-level frequency multiplexing scheme for readout of scaled-up spin qubit devices. By integrating separate bias tees and resonator circuits on-chip for each readout channel, we realise dispersive gate-sensing in combination with charge detection based on two radio frequency quantum point contacts. We apply this approach to perform multiplexed readout of a double quantum dot in the few-electron regime and further demonstrate operation of a 10-channel multiplexing device. Limitations for scaling spin qubit readout to large numbers of multiplexed channels are discussed.

  8. Diffusion-weighted MR imaging and ADC mapping in differentiating benign from malignant thyroid nodules

    International Nuclear Information System (INIS)

    Khizer, A.T.; Slehria, A.U.R.

    2015-01-01

    To determine the diagnostic accuracy of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) mapping in differentiating benign from malignant thyroid nodules by taking histopathology as the gold standard. Study Design:Across-sectional analytical study. Place and Duration of Study: Department of Radiology at Combined Military Hospital (CMH), Lahore, from August 2012 to July 2013. Methodology: Thirty-five patients, who were referred to radiology department of CMH, Lahore, for ultrasound or Fine Needle Aspiration Cytology (FNAC) of thyroid gland, fulfilling the inclusion and exclusion criteria, were included in the study. They were evaluated on 1.5 Tesla MRI machine with T1- and T2-weighted imaging as well as fat-suppressed technique. DWI was done using b-values of 0 and 1000 s/mm2 and ADC values were calculated for the thyroid nodules. All of these patients were subjected to ultrasound guided core biopsy and histopathology results were correlated with ADC values. Results: The benign nodules showed facilitated diffusion while malignant nodules showed restricted diffusion. T-test was used to assess the difference in mean ADC values between benign and malignant nodules. The mean ADC value of the malignant thyroid nodules (0.94 ± 0.16 x 10/sup -3/mm2/s) was significantly lower than that of the benign thyroid nodules (1.93 ±0.13 x 10/sup -3/mm2/s) (p-value < 0.05). ADC value of 1.6 x 10/sup -3/mm2/s was used as a cut-off, for differentiating benign from malignant thyroid nodules. The sensitivity, specificity, PPV, NPV and diagnostic accuracy of DWI and ADC values in differentiating benign from malignant thyroid nodules were 93%, 95%, 93%, 95% and 92.3%, respectively. Conclusion: DWI is a non-invasive diagnostic tool for characterization and differentiation between benign and malignant thyroid nodules. It not only decreases the burden of unnecessary surgeries when pre-operative FNAC and biopsy are inconclusive, but is also helpful in reaching a

  9. Whole lesion histogram analysis of meningiomas derived from ADC values. Correlation with several cellularity parameters, proliferation index KI 67, nucleic content, and membrane permeability.

    Science.gov (United States)

    Surov, Alexey; Hamerla, Gordian; Meyer, Hans Jonas; Winter, Karsten; Schob, Stefan; Fiedler, Eckhard

    2018-09-01

    To analyze several histopathological features and their possible correlations with whole lesion histogram analysis derived from ADC maps in meningioma. The retrospective study involved 36 patients with primary meningiomas. For every tumor, the following histogram analysis parameters of apparent diffusion coefficient (ADC) were calculated: ADC mean , ADC max , ADC min , ADC median , ADC mode , ADC percentiles: P10, P25, P75, P90, as well kurtosis, skewness, and entropy. All measures were performed by two radiologists. Proliferation index KI 67, minimal, maximal and mean cell count, total nucleic area, and expression of water channel aquaporin 4 (AQP4) were estimated. Spearman's correlation coefficient was used to analyze associations between investigated parameters. A perfect interobserver agreement for all ADC values (0.84-0.97) was identified. All ADC values correlated inversely with tumor cellularity with the strongest correlation between P10, P25 and mean cell count (-0.558). KI 67 correlated inversely with all ADC values except ADC min . ADC parameters did not correlate with total nucleic area. All ADC values correlated statistically significant with expression of AQP4. ADC histogram analysis is a valid method with an excellent interobserver agreement. Cellularity parameters and proliferation potential are associated with different ADC values. Membrane permeability may play a greater role for water diffusion than cell count and proliferation activity. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Alterations of apparent diffusion coefficient (ADC) in the brain of rats chronically exposed to lead acetate.

    Science.gov (United States)

    López-Larrubia, Pilar; Cauli, Omar

    2011-03-15

    Diffusion-weighted imaging (DWI) allows the assessment of the water apparent diffusion coefficient (ADC), a measure of tissue water diffusivity which is altered during different pathological conditions such as cerebral oedema. By means of DWI, we repeatedly measured in the same rats apparent diffusion coefficient ADC in different brain areas (motor cortex (MCx), somato-sensory cortex (SCx), caudate-putamen (CPu), hippocampus (Hip), mesencephalic reticular formation (RF), corpus callosum (CC) and cerebellum (Cb)) after 1 week, 4 and 12 weeks of lead acetate exposure via drinking water (50 or 500 ppm). After 12 weeks of lead exposure rats received albumin-Evans blue complex administration and were sacrificed 1h later. Blood-brain barrier permeability and water tissue content were determined in order to evaluate their relationship with ADC changes. Chronic exposure to lead acetate (500 ppm) for 4 weeks increased ADC values in Hip, RF and Cb but no in other brain areas. After 12 weeks of lead acetate exposure at 500 ppm ADC is significantly increased also in CPu and CC. Brain areas displaying high ADC values after lead exposure showed also an increased water content and increased BBB permeability to Evans blue-albumin complex. Exposure to 50 ppm for 12 weeks increased ADC values and BBB permeability in the RF and Cb. In summary, chronic lead exposure induces cerebral oedema in the adult brain depending on the brain area and the dose of exposure. RF and Cb appeared the most sensitive brain areas whereas cerebral cortex appears resistant to lead-induced cerebral oedema. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  11. A 2-GS/s 6-bit self-calibrated flash ADC

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Youtao; Chen Chen [National Key Laboratory of Monolithic Integrated Circuits and Modules, Nanjing Electronic Devices Institute, Nanjing 210016 (China); Li Xiaopeng; Zhang Min; Liu Ao, E-mail: zhangyt@nedc-ic.co [Nanjing Electronic Devices Institute, Nanjing 210016 (China)

    2010-09-15

    A single channel 2-GS/s 6-bit ADC with cascade resistive averaging and self foreground calibration is demonstrated in 0.18-{mu}m CMOS. The calibration method based on DAC trimming improves the linearity and dynamic performance further. The peak DNL and INL are measured as 0.34 and 0.22 LSB, respectively. The SNDR and SFDR have achieved 36.5 and 45.9 dB, respectively, with 1.22 MHz input signal and 2 GS/s. The proposed ADC, including on-chip track-and-hold amplifiers and clock buffers, consumes 570 mW from a single 1.8 V supply while operating at 2 GS/s. (semiconductor integrated circuits)

  12. A Discrete Component Low-Noise Preamplifier Readout for a Linear (1x16) SiC Photodiode Array

    Science.gov (United States)

    Kahle, Duncan; Aslam, Shahid; Herrero, Frederico A.; Waczynski, Augustyn

    2016-01-01

    A compact, low-noise and inexpensive preamplifier circuit has been designed and fabricated to optimally readout a common cathode (1x16) channel 4H-SiC Schottky photodiode array for use in ultraviolet experiments. The readout uses an operational amplifier with 10 pF capacitor in the feedback loop in parallel with a low leakage switch for each of the channels. This circuit configuration allows for reiterative sample, integrate and reset. A sampling technique is given to remove Johnson noise, enabling a femtoampere level readout noise performance. Commercial-off-the-shelf acquisition electronics are used to digitize the preamplifier analogue signals. The data logging acquisition electronics has a different integration circuit, which allows the bandwidth and gain to be independently adjusted. Using this readout, photoresponse measurements across the array between spectral wavelengths 200 nm and 370 nm are made to establish the array pixels external quantum efficiency, current responsivity and noise equivalent power.

  13. A discrete component low-noise preamplifier readout for a linear (1×16) SiC photodiode array

    Energy Technology Data Exchange (ETDEWEB)

    Kahle, Duncan [NASA, Goddard Space Flight Center, Detector Systems Branch, Greenbelt, MD 20771 (United States); Aslam, Shahid, E-mail: shahid.aslam-1@nasa.gov [NASA, Goddard Space Flight Center, Planetary Systems Laboratory, Greenbelt, MD 20771 (United States); Herrero, Federico A.; Waczynski, Augustyn [NASA, Goddard Space Flight Center, Detector Systems Branch, Greenbelt, MD 20771 (United States)

    2016-09-11

    A compact, low-noise and inexpensive preamplifier circuit has been designed and fabricated to optimally readout a common cathode (1×16) channel 4H-SiC Schottky photodiode array for use in ultraviolet experiments. The readout uses an operational amplifier with 10 pF capacitor in the feedback loop in parallel with a low leakage switch for each of the channels. This circuit configuration allows for reiterative sample, integrate and reset. A sampling technique is given to remove Johnson noise, enabling a femtoampere level readout noise performance. Commercial-off-the-shelf acquisition electronics are used to digitize the preamplifier analog signals. The data logging acquisition electronics has a different integration circuit, which allows the bandwidth and gain to be independently adjusted. Using this readout, photoresponse measurements across the array between spectral wavelengths 200 nm and 370 nm are made to establish the array pixels external quantum efficiency, current responsivity and noise equivalent power.

  14. CAMAC interface module for PACE ADC system

    Energy Technology Data Exchange (ETDEWEB)

    Dalton, C G; Mischke, R E [Los Alamos Scientific Lab., N.Mex. (USA); Scott, D T

    1977-03-15

    This report describes a CAMAC module designed to buffer and transfer data from the Tennelec multiplexed ADC system called PACE to a computer. It can be operated in either of two modes: as an eight-deep, first-in-first-out (FIFO) circular buffer, or in channel mode with a single buffer reserved for each PACE channel.

  15. The appearance of ADCs in the non-affected areas of the patients with MELAS

    International Nuclear Information System (INIS)

    Liu, Zhenghua; Liu, Xiwei; Hui, Lihong; Xie, Sheng; Xiao, Jiangxi; Jiang, Xuexiang; Zhao, Danhua; Wang, Xiaoying

    2011-01-01

    The exact mechanism of the mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS) remain unclear. Diffusion-weighted imaging (DWI) is a magnetic resonance (MR) imaging technique for studying the pathophysiologic change of the MELAS. The purpose of the study is to see whether the apparent diffusion coefficient (ADC) of MELAS in the non-affected areas is different from the ADC of the normal subjects and to speculate the pathophysiological mechanisms of the MELAS. Sixteen cases of MELAS were retrospectively analyzed. Thirty healthy subjects were chosen to constitute the control group. All of them were performed on the 3.0T whole-body MR scanner with axial view T2 fluid attenuated inversion recovery (flair), T2-weighted imaging, T1flair, and DWI. An ADC map was reconstructed in the workstation. Two to five regions of interest were put in the non-affected frontal lobe and basal ganglia. All data took statistical analysis. There were significant differences between the ADC of the patients with MELAS and the controls in the non-affected areas, including the superior frontal gyrus, precentral gyrus, corpus striatum, thalamus, and white matter of the semi-oval centrum. ADCs in the non-affected areas of the patients with MELAS are higher than those of the normal subjects. Pathological changes take place in the non-affected areas of the patients with MELAS. (orig.)

  16. The appearance of ADCs in the non-affected areas of the patients with MELAS

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhenghua; Liu, Xiwei; Hui, Lihong; Xie, Sheng; Xiao, Jiangxi; Jiang, Xuexiang [Peking University First Hospital, Center for Functional Imaging, Peking University, The Department of Radiology, Beijing (China); Zhao, Danhua [Peking University First Hospital, The Department of Neurology, Beijing (China); Wang, Xiaoying [Peking University First Hospital, Center for Functional Imaging, Peking University, The Department of Radiology, Beijing (China); Peking University First Hospital, The Department of Radiology, 8, Xishiku Street, Xicheng District, Beijing (China)

    2011-04-15

    The exact mechanism of the mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS) remain unclear. Diffusion-weighted imaging (DWI) is a magnetic resonance (MR) imaging technique for studying the pathophysiologic change of the MELAS. The purpose of the study is to see whether the apparent diffusion coefficient (ADC) of MELAS in the non-affected areas is different from the ADC of the normal subjects and to speculate the pathophysiological mechanisms of the MELAS. Sixteen cases of MELAS were retrospectively analyzed. Thirty healthy subjects were chosen to constitute the control group. All of them were performed on the 3.0T whole-body MR scanner with axial view T2 fluid attenuated inversion recovery (flair), T2-weighted imaging, T1flair, and DWI. An ADC map was reconstructed in the workstation. Two to five regions of interest were put in the non-affected frontal lobe and basal ganglia. All data took statistical analysis. There were significant differences between the ADC of the patients with MELAS and the controls in the non-affected areas, including the superior frontal gyrus, precentral gyrus, corpus striatum, thalamus, and white matter of the semi-oval centrum. ADCs in the non-affected areas of the patients with MELAS are higher than those of the normal subjects. Pathological changes take place in the non-affected areas of the patients with MELAS. (orig.)

  17. Study of the spatial resolution for binary readout detectors

    Energy Technology Data Exchange (ETDEWEB)

    Yonamine, R., E-mail: ryo.yonamine@ulb.ac.be; Maerschalk, T.; Lentdecker, G. De

    2016-07-11

    Often the binary readout is proposed for high granularity detectors to reduce the generated data volume to be readout at the price of a somewhat reduced spatial resolution compared to an analogue readout. We have been studying single hit resolutions obtained with a binary readout using simulations as well as analytical approaches. In this note we show that the detector geometry could be optimized to offer an equivalent spatial resolution than with an analogue readout.

  18. Achievable ADC Performance by Postcorrection Utilizing Dynamic Modeling of the Integral Nonlinearity

    Directory of Open Access Journals (Sweden)

    Peter Händel

    2008-03-01

    Full Text Available There is a need for a universal dynamic model of analog-to-digital converters (ADC’s aimed for postcorrection. However, it is complicated to fully describe the properties of an ADC by a single model. An alternative is to split up the ADC model in different components, where each component has unique properties. In this paper, a model based on three components is used, and a performance analysis for each component is presented. Each component can be postcorrected individually and by the method that best suits the application. The purpose of postcorrection of an ADC is to improve the performance. Hence, for each component, expressions for the potential improvement have been developed. The measures of performance are total harmonic distortion (THD and signal to noise and distortion (SINAD, and to some extent spurious-free dynamic range (SFDR.

  19. TELL1 data acquisition system for LHCb detectors

    International Nuclear Information System (INIS)

    Gong Guanghua; Xue Tao; Gong Hui; Shao Beibei

    2004-01-01

    A FPGA based data acquisition readout board has been developed for the LHCb detectors. With optical or analogue daughter cards, it can readout data from several different off-detector electronics. The data synchronization, buffering, pre-processing, zero-suppression and many interfaces to memory chips and communication buses are all implemented by the FPGA in VHDL code. The board sends data out via a 4 channel Gigabit Ethernet adapter. The TELL1 can accepts 24 optical links running at 1.6 GHz and provides for the analogue option 64 10-bit ADC channels sampling at 40 MHz. (authors)

  20. Performance study of large area encoding readout MRPC

    Science.gov (United States)

    Chen, X. L.; Wang, Y.; Chen, G.; Han, D.; Wang, X.; Zeng, M.; Zeng, Z.; Zhao, Z.; Guo, B.

    2018-02-01

    Muon tomography system built by the 2-D readout high spatial resolution Multi-gap Resistive Plate Chamber (MRPC) detector is a project of Tsinghua University. An encoding readout method based on the fine-fine configuration has been used to minimize the number of the readout electronic channels resulting in reducing the complexity and the cost of the system. In this paper, we provide a systematic comparison of the MRPC detector performance with and without fine-fine encoding readout. Our results suggest that the application of the fine-fine encoding readout leads us to achieve a detecting system with slightly worse spatial resolution but dramatically reduce the number of electronic channels.

  1. Diffusion Weighted Imaging of the Uterus: Regional ADC Variation with Oral Contraceptive Usage and Comparison with Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Messiou, Christina; Morgan, Veronica A.; Silva, Sonali S. de; Souza, Nandita M. de (Cancer Research UK Clinical Magnetic Resonance Research Group, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom)); Ind, Thomas E. (Dept. of Gynaecology and Obstetrics, St George' s Hospital NHS Trust, London (United Kingdom))

    2009-07-15

    Background: There is growing interest in diffusion weighted magnetic resonance imaging (MRI) of cervical carcinoma but normal uterine appearances and effects of the oral contraceptive pill (OCP) have not been described. Purpose: To establish apparent diffusion coefficient (ADC) values for normal regions of uterus, determine the effect of the OCP on these values, and compare them with ADCs from cervical cancer. Material and Methods: Twenty-seven premenopausal women (19 taking the OCP) with cervical intraepithelial neoplasia (CIN) were studied with T2W and diffusion weighted MRI (DW-MRI). Regions of interest were drawn on ADC maps by visual matching with T2W images on different zones of the uterus and values compared between women not taking and taking the OCp.A further group of 25 women with clinically obvious tumors of the cervix were also studied with T2W and DW-MRI and ADC values of tumor were compared with ADC values of cervical epithelium and stroma. Results: The ADC values of adjacent zones of the uterus and cervix were significantly different from one another (P<0.001). The junctional zone was seen as a band of restricted diffusion between endometrium and outer myometrium. The ADC value of the junctional zone of the uterus was significantly greater (P<0.001) in patients taking the OCP than those patients not taking the OCp.There was no significant affect of the OCP on the ADC values of other uterine zones. Conclusion: The zonal anatomy of the uterus is well demonstrated by DW-MRI with hormonal effects secondary to the OCP affecting junctional zone alone. ADC of cervical tumor is significantly different to cervical epithelium and stroma indicating a role in cervical cancer detection and local staging

  2. Diffusion Weighted Imaging of the Uterus: Regional ADC Variation with Oral Contraceptive Usage and Comparison with Cervical Cancer

    International Nuclear Information System (INIS)

    Messiou, Christina; Morgan, Veronica A.; Silva, Sonali S. de; Souza, Nandita M. de; Ind, Thomas E.

    2009-01-01

    Background: There is growing interest in diffusion weighted magnetic resonance imaging (MRI) of cervical carcinoma but normal uterine appearances and effects of the oral contraceptive pill (OCP) have not been described. Purpose: To establish apparent diffusion coefficient (ADC) values for normal regions of uterus, determine the effect of the OCP on these values, and compare them with ADCs from cervical cancer. Material and Methods: Twenty-seven premenopausal women (19 taking the OCP) with cervical intraepithelial neoplasia (CIN) were studied with T2W and diffusion weighted MRI (DW-MRI). Regions of interest were drawn on ADC maps by visual matching with T2W images on different zones of the uterus and values compared between women not taking and taking the OCp.A further group of 25 women with clinically obvious tumors of the cervix were also studied with T2W and DW-MRI and ADC values of tumor were compared with ADC values of cervical epithelium and stroma. Results: The ADC values of adjacent zones of the uterus and cervix were significantly different from one another (P<0.001). The junctional zone was seen as a band of restricted diffusion between endometrium and outer myometrium. The ADC value of the junctional zone of the uterus was significantly greater (P<0.001) in patients taking the OCP than those patients not taking the OCp.There was no significant affect of the OCP on the ADC values of other uterine zones. Conclusion: The zonal anatomy of the uterus is well demonstrated by DW-MRI with hormonal effects secondary to the OCP affecting junctional zone alone. ADC of cervical tumor is significantly different to cervical epithelium and stroma indicating a role in cervical cancer detection and local staging

  3. An inverter-based capacitive trans-impedance amplifier readout with offset cancellation and temporal noise reduction for IR focal plane array

    Science.gov (United States)

    Chen, Hsin-Han; Hsieh, Chih-Cheng

    2013-09-01

    This paper presents a readout integrated circuit (ROIC) with inverter-based capacitive trans-impedance amplifier (CTIA) and pseudo-multiple sampling technique for infrared focal plane array (IRFPA). The proposed inverter-based CTIA with a coupling capacitor [1], executing auto-zeroing technique to cancel out the varied offset voltage from process variation, is used to substitute differential amplifier in conventional CTIA. The tunable detector bias is applied from a global external bias before exposure. This scheme not only retains stable detector bias voltage and signal injection efficiency, but also reduces the pixel area as well. Pseudo-multiple sampling technique [2] is adopted to reduce the temporal noise of readout circuit. The noise reduction performance is comparable to the conventional multiple sampling operation without need of longer readout time proportional to the number of samples. A CMOS image sensor chip with 55×65 pixel array has been fabricated in 0.18um CMOS technology. It achieves a 12um×12um pixel size, a frame rate of 72 fps, a power-per-pixel of 0.66uW/pixel, and a readout temporal noise of 1.06mVrms (16 times of pseudo-multiple sampling), respectively.

  4. A 2D 4×4 Channel Readout ASIC for Pixelated CdTe Detectors for Medical Imaging Applications.

    Science.gov (United States)

    Macias-Montero, Jose-Gabriel; Sarraj, Maher; Chmeissani, Mokhtar; Martínez, Ricardo; Puigdengoles, Carles

    2015-10-01

    We present a 16-channel readout integrated circuit (ROIC) with nanosecond-resolution time to digital converter (TDC) for pixelated Cadmium Telluride (CdTe) gamma-ray detectors. The 4 × 4 pixel array ROIC is the proof of concept of the 10 × 10 pixel array readout ASIC for positron-emission tomography (PET) scanner, positron-emission mammography (PEM) scanner, and Compton gamma camera. The electronics of each individual pixel integrates an analog front-end with switchable gain, an analog to digital converter (ADC), configuration registers, and a 4-state digital controller. For every detected photon, the pixel electronics provides the energy deposited in the detector with 10-bit resolution, and a fast trigger signal for time stamp. The ASIC contains the 16-pixel matrix electronics, a digital controller, five global voltage references, a TDC, a temperature sensor, and a band-gap based current reference. The ASIC has been fabricated with TSMC 0.25 μ m mixed-signal CMOS technology and occupies an area of 5.3 mm × 6.8 mm. The TDC shows a resolution of 95.5 ps, a precision of 600 ps at full width half maximum (FWHM), and a power consumption of 130 μ W. In acquisition mode, the total power consumption of every pixel is 200 μ W. An equivalent noise charge (ENC) of 160 e - RMS at maximum gain and negative polarity conditions has been measured at room temperature.

  5. BATS, the readout control of UA1

    Energy Technology Data Exchange (ETDEWEB)

    Botlo, M.; Dorenbosch, J.; Jimack, M.; Szoncso, F.; Taurok, A.; Walzel, G. (European Organization for Nuclear Research, Geneva (Switzerland))

    1991-04-15

    A steadily rising luminosity and different readout architectures for the various detector systems of UA1 required a new data flow control to minimize the dead time. BATS, a finite state machine conceived around two microprocessors in a single VME crate, improved flexibility and reliability. Compatibility with BATS streamlined all readout branches. BATS also proved to be a valuable asset in spotting readout problems and previously undetected data flow bottlenecks. (orig.).

  6. Design and implementation of an MCA card with double ADC for nuclear radiation analysis

    International Nuclear Information System (INIS)

    Razanabololona, V.H.

    2001-01-01

    The rapid development of technology has triggered several interesting trends in nuclear instrumentation. In particular, the introduction of add-on cards that can serve as multichannel analyzer and offer adequate performance for most of the nuclear applications. The purpose of this thesis has been the design of a multichannel analyser inserted into microcomputer. The originality of this prototype MCA card with its innovative concept is the use of two analog digital converters or ADC of which the objective is to reduce to minima the lost of pulses during the acquisition and the signals processing. The first ADC works as the main converter (or master) and the second ADC the slave converter. The first ADC begins the first signals acquisition, while it will be busy for the processing, the second ADC continues the acquisition, thus there will be no lost pulses or precisely lost of pulses will be reduced to minima.The three main points for a multichannel analyzer will be studied such a the pile-up, the differential non-linearity or 'DNL' and the dead time. In the first part of this thesis the function of the MCA has been described and the different roles of the composed modules have been developed. In the second part, spectra analysis has been done with the MCA prototype as well the comparison with other MCAs such as MCAs S100, TISA, MCA35+, and the Inspector. [fr

  7. Value of apparent diffusion coefficient (ADC) in assessing radiotherapy and chemotherapy success in cervical cancer.

    Science.gov (United States)

    Fu, Zhan-Zhao; Peng, Yong; Cao, Li-Yan; Chen, Yan-Sheng; Li, Kun; Fu, Bao-Hong

    2015-06-01

    We investigated the clinical significance of apparent diffusion coefficient (ADC) values in diffusion-weighted magnetic resonance imaging (DWI) in monitoring the efficacy of radiotherapy (RT) and chemotherapy (CT) treatments in cervical cancer. In order to identify relevant high quality clinical cohort studies reporting the use of DWI in cervical cancers, the following electronic databases in English and Chinese languages were comprehensively searched: MEDLINE, Science Citation Index database, Cochrane Library Database, PubMed, Embase, CINAHL, and Current Contents Index; Chinese Biomedical Database, Chinese Journal Full-Text Database. All selected studies were published prior to March 2014, and data extracted from these studies were analyzed using STATA 12.0 statistical software. We initially retrieved 196 articles (79 Chinese articles and 117 English articles) through database searches and finally selected sixteen cohort studies for this meta-analysis. The 16 studies contained a combined total of 517 subjects, and all selected studies reported the mean ADC value (10(-3) mm(2)/s) in DWI in cervical cancer patients treated with RT and CT. Combined standardized mean difference (SMD) suggested that the mean post-RT and mean post-CT ADC values were significantly higher than the mean pre-RT and mean pre-CT ADC values, respectively, in cervical cancer patients (SMD=2.95, 95% CI=2.19-3.72, P900 (SMD=2.55, 95% CI=1.78-3.32, P<0.001). The mean ADC value in patients without residual tumor post-RT and post-CT treatment was significantly higher than seen in patients with residual tumors (SMD=0.80, 95% CI=0.49-1.12, P<0.001). Our meta-analysis revealed a significant correlation between mean ADC values and the clinical response to RT and CT treatment. Thus, ADC values in DWI may be effective in evaluating the clinical outcome of treatments in cervical cancer patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Quantitative evaluation of bone metastases from prostate cancer with simultaneous [18F] choline PET/MRI. Combined SUV and ADC analysis

    International Nuclear Information System (INIS)

    Wetter, A.; Lipponer, C.; Nensa, F.; Schlosser, T.W.; Lauenstein, T.C.; Heusch, P.; Ruebben, H.; Poeppel, T.D.; Nagarajah, J.

    2014-01-01

    To quantitatively analyze bone metastases from prostate cancer and correlate the apparent diffusion coefficients (ADCs) and standardized uptake values (SUVs). Fifty-five patients with biopsy-proven prostate cancer or suspected recurrent prostate cancer were examined with simultaneous [ 18 F] choline Positron emission tomography (PET)/MRI at 3 T. In 11 patients, thirty-two PET-positive bone lesions could be identified that were located in the field-of-view of the Diffusion weighted imaging-sequence. Region-of-interest and volume-of-interest analyses were performed to measure the mean and minimal ADCs and to assess maximum and mean SUVs of every bone lesion. Correlations between maximum and mean SUVs and mean and minimal ADCs were calculated. The SUV max of all lesions was 5.5 ± 3.1 (mean ± SD). The SUV mean was 1.8 ± 0.9. The mean ADC (ADC mean ) of all lesions was 0.67 ± 0.13 x 10 -3 mm 2 /s. The minimal ADC (ADC min ) of all lesions was 0.56 ± 0.14 x 10 -3 mm 2 /s. There was a moderate but significant inverse correlation of SUV max vs. ADC mean with a correlation coefficient of -0.4 (p=0.02). There was also a significant inverse correlation of SUV max vs. ADC min with r=-0.41 (p=0.02). Our initial results demonstrate a moderate but significant inverse correlation between increased choline metabolism and ADC values of bone metastases from prostate cancer. Further research on a multimodality approach using simultaneous PET/MRI in bone metastasis of prostate cancer seems to be justified. (author)

  9. A readout system for the micro-vertex-detector demonstrator for the CBM experiment at FAIR

    Energy Technology Data Exchange (ETDEWEB)

    Schrader, Christoph

    2011-06-09

    The Compressed Baryonic Matter Experiment (CBM) is a fixed target heavy ion experiment currently in preparation at the future FAIR accelerator complex in Darmstadt. The CBM experiment focuses on the measurements of diagnostic probes of the early and dense phase of the fireball at beam energies from 8 up to 45 AGeV. As observables, rare hadronic, leptonic and photonic probes are used, including open charm. Open charm will be identified by reconstructing the secondary decay vertex of the corresponding short lived particles. As the central component for track reconstruction, a detector system based on silicon semiconductor detectors is planned. The first three stations of the Silicon Tracking System (STS) make up the so-called Micro-Vertex-Detector (MVD) operating in moderate vacuum. Because of the well-balanced compromise between an excellent spatial resolution (few {mu}m), low material budget ({proportional_to}50 {mu}m Si), adequate radiation tolerance and readout speed, Monolithic Active Pixel Sensors (MAPS) based on CMOS technology are more suited than any other technology for the reconstruction of the secondary vertex in CBM. A new detector concept has to be developed. Two MVD-Demonstrator modules have been successfully tested with 120 GeV pions at the CERN-SPS. The main topic of this thesis is the development of a control and readout concept of several MVD-Demonstrator modules with a common data acquisition system. In order to achieve the required results a front-end electronics device has been developed which is capable of reading the analogue signals of two sensors on a ex-print cable. The high data rate of the MAPS sensors (1.2 Gbit per second and sensor by 50 MHz and 12 bit ADC resolution) requires a readout system which processes the data on-line in a pipeline to avoid dead times. In order to implement the pipeline processing an FPGA is used, which is located on an additional hardware platform. In order to integrate the MVD-Demonstrator readout board in the

  10. A readout system for the micro-vertex-detector demonstrator for the CBM experiment at FAIR

    International Nuclear Information System (INIS)

    Schrader, Christoph

    2011-01-01

    The Compressed Baryonic Matter Experiment (CBM) is a fixed target heavy ion experiment currently in preparation at the future FAIR accelerator complex in Darmstadt. The CBM experiment focuses on the measurements of diagnostic probes of the early and dense phase of the fireball at beam energies from 8 up to 45 AGeV. As observables, rare hadronic, leptonic and photonic probes are used, including open charm. Open charm will be identified by reconstructing the secondary decay vertex of the corresponding short lived particles. As the central component for track reconstruction, a detector system based on silicon semiconductor detectors is planned. The first three stations of the Silicon Tracking System (STS) make up the so-called Micro-Vertex-Detector (MVD) operating in moderate vacuum. Because of the well-balanced compromise between an excellent spatial resolution (few μm), low material budget (∝50 μm Si), adequate radiation tolerance and readout speed, Monolithic Active Pixel Sensors (MAPS) based on CMOS technology are more suited than any other technology for the reconstruction of the secondary vertex in CBM. A new detector concept has to be developed. Two MVD-Demonstrator modules have been successfully tested with 120 GeV pions at the CERN-SPS. The main topic of this thesis is the development of a control and readout concept of several MVD-Demonstrator modules with a common data acquisition system. In order to achieve the required results a front-end electronics device has been developed which is capable of reading the analogue signals of two sensors on a ex-print cable. The high data rate of the MAPS sensors (1.2 Gbit per second and sensor by 50 MHz and 12 bit ADC resolution) requires a readout system which processes the data on-line in a pipeline to avoid dead times. In order to implement the pipeline processing an FPGA is used, which is located on an additional hardware platform. In order to integrate the MVD-Demonstrator readout board in the HADES data

  11. Brain development during the first year of life. Quantitative assessment with ADC imaging

    International Nuclear Information System (INIS)

    Okuda, Yasuyuki

    1994-01-01

    Brain development during the first year of life was assessed quantitatively using apparent diffusion coefficient (ADC) images constructed from diffusion-weighted MR image data. The imaging plane was coronal at the section of the pons. The cerebral peduncle, internal capsule, corona radiata, superior longitudinal fasciculus and thalamus were selected for evaluation of their ADC values. A diffusion sensitive gradient was added in the anteroposterior direction. Thus the orientation of nerve fibers in the cerebral peduncle, internal capsule and corona radiata was perpendicular to it, and that in the superior longitudinal fasciculus was parallel to it. In neonates, the cerebral peduncle and internal capsule, having been moderately myelinated at birth, showed the slowest diffusion. The corona radiata and superior longitudinal fasciculus, having been unmyelinated at birth, showed the fastest diffusion. The thalamus had intermediate diffusion. These neonatal diffusions tended to be promptly restricted within the first five months, followed by additional slight restriction thereafter. ADC values in the first year were significantly reduced in all regions compared with those in the neonatal period, particularly in the corona radiata and thalamus. This study showed that ADC analysis can estimate normal brain development in detail and might be useful for investigating various neonatal brain diseases. (author)

  12. Corrected RMS Error and Effective Number of Bits for Sinewave ADC Tests

    International Nuclear Information System (INIS)

    Jerome J. Blair

    2002-01-01

    A new definition is proposed for the effective number of bits of an ADC. This definition removes the variation in the calculated effective bits when the amplitude and offset of the sinewave test signal is slightly varied. This variation is most pronounced when test signals with amplitudes of a small number of code bin widths are applied to very low noise ADC's. The effectiveness of the proposed definition is compared with that of other proposed definitions over a range of signal amplitudes and noise levels

  13. Pulse oximeter improvement with an ADC-DAC feedback loop and a radial reflectance sensor.

    Science.gov (United States)

    Thompson, David; Wareing, Austin; Day, Dwight; Warren, Steve

    2006-01-01

    Pulse oximeter circuitry must meet several design constraints, including the ability to separate a small pulsatile signal component from a large signal baseline. This paper describes pulse oximeter design changes that produced order-of-magnitude improvements in signal quality. The primary changes were (a) the replacement of an analog sample-and-hold-based differentiator circuit with an ADC-DAC feedback loop and (b) the replacement of a side-by-side reflectance sensor design with a radial sensor arrangement that maximizes the pulsatile-to-baseline signal ratio.

  14. Real time prediction and correction of ADCS problems in LEO satellites using fuzzy logic

    Directory of Open Access Journals (Sweden)

    Yassin Mounir Yassin

    2017-06-01

    Full Text Available This approach is concerned with adapting the operations of attitude determination and control subsystem (ADCS of low earth orbit LEO satellites through analyzing the telemetry readings received by mission control center, and then responding to ADCS off-nominal situations. This can be achieved by sending corrective operational Tele-commands within real time. Our approach is related to the fuzzy membership of off-nominal telemetry readings of corrective actions through a set of fuzzy rules based on understanding the ADCS modes resulted from the satellite telemetry readings. Response in real time gives us a chance to avoid risky situations. The approach is tested on the EgyptSat-1 engineering model, which is our method to simulate the results.

  15. Performance of the Electronic Readout of the ATLAS Liquid Argon Calorimeters

    CERN Document Server

    Abreu, H; Aleksa, M; Aperio Bella, L; Archambault, JP; Arfaoui, S; Arnaez, O; Auge, E; Aurousseau, M; Bahinipati, S; Ban, J; Banfi, D; Barajas, A; Barillari, T; Bazan, A; Bellachia, F; Beloborodova, O; Benchekroun, D; Benslama, K; Berger, N; Berghaus, F; Bernat, P; Bernier, R; Besson, N; Binet, S; Blanchard, JB; Blondel, A; Bobrovnikov, V; Bohner, O; Boonekamp, M; Bordoni, S; Bouchel, M; Bourdarios, C; Bozzone, A; Braun, HM; Breton, D; Brettel, H; Brooijmans, G; Caputo, R; Carli, T; Carminati, L; Caughron, S; Cavalleri, P; Cavalli, D; Chareyre, E; Chase, RL; Chekulaev, SV; Chen, H; Cheplakov, A; Chiche, R; Citterio, M; Cojocaru, C; Colas, J; Collard, C; Collot, J; Consonni, M; Cooke, M; Copic, K; Costa, GC; Courneyea, L; Cuisy, D; Cwienk, WD; Damazio, D; Dannheim, D; De Cecco, S; De La Broise, X; De La Taille, C; de Vivie, JB; Debennerot, B; Delagnes, E; Delmastro, M; Derue, F; Dhaliwal, S; Di Ciaccio, L; Doan, O; Dudziak, F; Duflot, L; Dumont-Dayot, N; Dzahini, D; Elles, S; Ertel, E; Escalier, M; Etienvre, AI; Falleau, I; Fanti, M; Farooque, T; Favre, P; Fayard, Louis; Fent, J; Ferencei, J; Fischer, A; Fournier, D; Fournier, L; Fras, M; Froeschl, R; Gadfort, T; Gallin-Martel, ML; Gibson, A; Gillberg, D; Gingrich, DM; Göpfert, T; Goodson, J; Gouighri, M; Goy, C; Grassi, V; Gray, J; Guillemin, T; Guo, B; Habring, J; Handel, C; Heelan, L; Heintz, H; Helary, L; Henrot-Versille, S; Hervas, L; Hobbs, J; Hoffman, J; Hostachy, JY; Hoummada, A; Hrivnac, J; Hrynova, T; Hubaut, F; Huber, J; Iconomidou-Fayard, L; Iengo, P; Imbert, P; Ishmukhametov, R; Jantsch, A; Javadov, N; Jezequel, S; Jimenez Belenguer, M; Ju, XY; Kado, M; Kalinowski, A; Kar, D; Karev, A; Katsanos, I; Kazarinov, M; Kerschen, N; Kierstead, J; Kim, MS; Kiryunin, A; Kladiva, E; Knecht, N; Kobel, M; Koletsou, I; König, S; Krieger, P; Kukhtin, V; Kuna, M; Kurchaninov, L; Labbe, J; Lacour, D; Ladygin, E; Lafaye, R; Laforge, B; Lamarra, D; Lampl, W; Lanni, F; Laplace, S; Laskus, H; Le Coguie, A; Le Dortz, O; Le Maner, C; Lechowski, M; Lee, SC; Lefebvre, M; Leonhardt, K; Lethiec, L; Leveque, J; Liang, Z; Liu, C; Liu, T; Liu, Y; Loch, P; Lu, J; Ma, H; Mader, W; Majewski, S; Makovec, N; Makowiecki, D; Mandelli, L; Mangeard, PS; Mansoulie, B; Marchand, JF; Marchiori, G; Martin, D; Martin-Chassard, G; Martin dit Latour, B; Marzin, A; Maslennikov, A; Massol, N; Matricon, P; Maximov, D; Mazzanti, M; McCarthy, T; McPherson, R; Menke, S; Meyer, JP; Ming, Y; Monnier, E; Mooshofer, P; Neganov, A; Niedercorn, F; Nikolic-Audit, I; Nugent, IM; Oakham, G; Oberlack, H; Ocariz, J; Odier, J; Oram, CJ; Orlov, I; Orr, R; Parsons, JA; Peleganchuk, S; Penson, A; Perini, L; Perrodo, P; Perrot, G; Perus, A; Petit, E; Pisarev, I; Plamondon, M; Poffenberger, P; Poggioli, L; Pospelov, G; Pralavorio, P; Prast, J; Prudent, X; Przysiezniak, H; Puzo, P; Quentin, M; Radeka, V; Rajagopalan, S; Rauter, E; Reimann, O; Rescia, S; Resende, B; Richer, JP; Ridel, M; Rios, R; Roos, L; Rosenbaum, G; Rosenzweig, H; Rossetto, O; Roudil, W; Rousseau, D; Ruan, X; Rudert, A; Rusakovich, N; Rusquart, P; Rutherfoord, J; Sauvage, G; Savine, A; Schaarschmidt, J; Schacht, P; Schaffer, A; Schram, M; Schwemling, P; Seguin Moreau, N; Seifert, F; Serin, L; Seuster, R; Shalyugin, A; Shupe, M; Simion, S; Sinervo, P; Sippach, W; Skovpen, K; Sliwa, R; Soukharev, A; Spano, F; Stavina, P; Straessner, A; Strizenec, P; Stroynowski, R; Talyshev, A; Tapprogge, S; Tarrade, F; Tartarelli, GF; Teuscher, R; Tikhonov, Yu; Tocut, V; Tompkins, D; Thompson, P; Tisserant, S; Todorov, T; Tomasz, F; Trincaz-Duvoid, S; Trinh, Thi N; Trochet, S; Trocme, B; Tschann-Grimm, K; Tsionou, D; Ueno, R; Unal, G; Urbaniec, D; Usov, Y; Voss, K; Veillet, JJ; Vincter, M; Vogt, S; Weng, Z; Whalen, K; Wicek, F; Wilkens, H; Wingerter-Seez, I; Wulf, E; Yang, Z; Ye, J; Yuan, L; Yurkewicz, A; Zarzhitsky, P; Zerwas, D; Zhang, H; Zhang, L; Zhou, N; Zimmer, J; Zitoun, R; Zivkovic, L

    2010-01-01

    The ATLAS detector has been designed for operation at the Large Hadron Collider at CERN. ATLAS includes electromagnetic and hadronic liquid argon calorimeters, with almost 200,000 channels of data that must be sampled at the LHC bunch crossing frequency of 40 MHz. The calorimeter electronics calibration and readout are performed by custom electronics developed specifically for these purposes. This paper describes the system performance of the ATLAS liquid argon calibration and readout electronics, including noise, energy and time resolution, and long term stability, with data taken mainly from full-system calibration runs performed after installation of the system in the ATLAS detector hall at CERN.

  16. Evolution of the dual-readout calorimeter

    Indian Academy of Sciences (India)

    ... a calorimeter system of a relatively simple construction and moderate costs, however with excellent properties, built upon experience gained with the extensively beam-tested DREAM (Dual REAdout. Module) prototype. The main idea of multiple readout calorimetry is to indepen- dently measure for each hadronic shower ...

  17. A multi-channel waveform digitizer system

    International Nuclear Information System (INIS)

    Bieser, F.; Muller, W.F.J.

    1990-01-01

    The authors report on the design and performance of a multichannel waveform digitizer system for use with the Multiple Sample Ionization Chamber (MUSIC) Detector at the Bevalac. 128 channels of 20 MHz Flash ADC plus 256 word deep memory are housed in a single crate. Digital thresholds and hit pattern logic facilitate zero suppression during readout which is performed over a standard VME bus

  18. Architecture of a modular, multichannel readout system for dense electrochemical biosensor microarrays

    International Nuclear Information System (INIS)

    Ramfos, Ioannis; Birbas, Alexios; Blionas, Spyridon

    2015-01-01

    The architecture of a modular, multichannel readout system for dense electrochemical microarrays, targeting Lab-on-a-Chip applications, is presented. This approach promotes efficient component reusability through a hybrid multiplexing methodology, maintaining high levels of sampling performance and accuracy. Two readout modes are offered, which can be dynamically interchanged following signal profiling, to cater for both rapid signal transitions and weak current responses. Additionally, functional extensions to the described architecture are discussed, which provide the system with multi-biasing capabilities. A prototype integrated circuit of the proposed architecture’s analog core and a supporting board were implemented to verify the working principles. The system was evaluated using standard loads, as well as electrochemical sensor arrays. Through a range of operating conditions and loads, the prototype exhibited a highly linear response and accurately delivered the readout of input signals with fast transitions and wide dynamic ranges. (paper)

  19. Treatment with the C5a receptor antagonist ADC-1004 reduces myocardial infarction in a porcine ischemia-reperfusion model

    Directory of Open Access Journals (Sweden)

    Arheden Håkan

    2010-09-01

    Full Text Available Abstract Background Polymorphonuclear neutrophils, stimulated by the activated complement factor C5a, have been implicated in cardiac ischemia/reperfusion injury. ADC-1004 is a competitive C5a receptor antagonist that has been shown to inhibit complement related neutrophil activation. ADC-1004 shields the neutrophils from C5a activation before they enter the reperfused area, which could be a mechanistic advantage compared to previous C5a directed reperfusion therapies. We investigated if treatment with ADC-1004, according to a clinically applicable protocol, would reduce infarct size and microvascular obstruction in a large animal myocardial infarct model. Methods In anesthetized pigs (42-53 kg, a percutaneous coronary intervention balloon was inflated in the left anterior descending artery for 40 minutes, followed by 4 hours of reperfusion. Twenty minutes after balloon inflation the pigs were randomized to an intravenous bolus administration of ADC-1004 (175 mg, n = 8 or saline (9 mg/ml, n = 8. Area at risk (AAR was evaluated by ex vivo SPECT. Infarct size and microvascular obstruction were evaluated by ex vivo MRI. The observers were blinded to the treatment at randomization and analysis. Results ADC-1004 treatment reduced infarct size by 21% (ADC-1004: 58.3 ± 3.4 vs control: 74.1 ± 2.9%AAR, p = 0.007. Microvascular obstruction was similar between the groups (ADC-1004: 2.2 ± 1.2 vs control: 5.3 ± 2.5%AAR, p = 0.23. The mean plasma concentration of ADC-1004 was 83 ± 8 nM at sacrifice. There were no significant differences between the groups with respect to heart rate, mean arterial pressure, cardiac output and blood-gas data. Conclusions ADC-1004 treatment reduces myocardial ischemia-reperfusion injury and represents a novel treatment strategy of myocardial infarct with potential clinical applicability.

  20. Fast high resolution ADC based on the flash type with a special error correcting technique

    Energy Technology Data Exchange (ETDEWEB)

    Xiao-Zhong, Liang; Jing-Xi, Cao [Beijing Univ. (China). Inst. of Atomic Energy

    1984-03-01

    A fast 12 bits ADC based on the flash type with a simple special error correcting technique which can effectively compensate the level drift of the discriminators and the droop of the stretcher voltage is described. The DNL is comparable with the Wilkinson's ADC and long term drift is far better than its.

  1. Simultaneous Measurement of T2 and Apparent Diffusion Coefficient (T2+ADC) in the Heart With Motion-Compensated Spin Echo Diffusion-Weighted Imaging

    Science.gov (United States)

    Aliotta, Eric; Moulin, Kévin; Zhang, Zhaohuan; Ennis, Daniel B.

    2018-01-01

    Purpose To evaluate a technique for simultaneous quantitative T2 and apparent diffusion coefficient (ADC) mapping in the heart (T2+ADC) using spin echo (SE) diffusion-weighted imaging (DWI). Theory and Methods T2 maps from T2+ADC were compared with single-echo SE in phantoms and with T2-prepared (T2-prep) balanced steady-state free precession (bSSFP) in healthy volunteers. ADC maps from T2+ADC were compared with conventional DWI in phantoms and in vivo. T2+ADC was also demonstrated in a patient with acute myocardial infarction (MI). Results Phantom T2 values from T2+ADC were closer to a single-echo SE reference than T2-prep bSSFP (−2.3 ± 6.0% vs 22.2 ± 16.3%; P T2 values from T2+ADC were significantly shorter than T2-prep bSSFP (35.8 ± 3.1 vs 46.8 ± 3.8 ms; P T2+ADC and conventional motion-compensated DWI (1.39 ± 0.18 vs 1.38 ± 0.18 mm2/ms; P = N.S.). In the patient, T2 and ADC were both significantly elevated in the infarct compared with remote myocardium (T2: 40.4 ± 7.6 vs 56.8 ± 22.0; P T2+ADC generated coregistered, free-breathing T2 and ADC maps in healthy volunteers and a patient with acute MI with no cost in accuracy, precision, or scan time compared with DWI. PMID:28516485

  2. Design and construction of the 8K multi-channel gamma spectrometer module (ADC+MCD)

    International Nuclear Information System (INIS)

    Vu Xuan Cach; Hoang Thi Ngoc Bich; Truong Van Dat; Pham Ngoc Tuan; Dang Lanh; Tuong Thi Thu Huong; Nguyen Xuan Hai

    2007-01-01

    A multichannel pulse-height analyzer system (MCA) consists of an ADC with 8192 channel performance, a histogramming memory, and a visual display of the histogram, implemented on a Personal Computer (PC). The purpose of the analog-to-digital converter (ADC) is to measure the maximum amplitude of an analog pulse, and convert that value into a digital number. This digital output is a proportional representation of the analog amplitude at the ADC input. The digital ADC outputs are stored in a histogram memory, where each bin represents a pulse height interval and the number of events in each bin represents the number of events in that interval. The combination of ADC, histogramming memory and display functions are the minimum to constitute a multichannel analyzer or MCA based on PC. It is designed and fabricated on a single NIM module. The communication between MCA module and PC implements via USB bus. In our application, performance of the USB standard version 1.1 is good enough for purposes. The application program was designed in LabWIEW 8.0 software. This application is the main display and acquisition software for the MCA module. It is compatible with Windows 98SE/XP. The libraries USB driver, with their supporting files, are in the FTD2XX driver DLL Package and D2XX function 7.0 for LabWIEW supporting. These libraries are used to write custom code to control the MCA module. The 8K MCA module has the main following hardware specifications: ADC Successive-approximation type with sliding scale linearization; resolution: 8192 channels; dead time per event: 5 μs, including memory transfer; integral nonlinearity: ±0.025% over the top 98% of the dynamic range; differential nonlinearity: < ±1% over the top 98% of the dynamic range; data memory: 224 counts per channel (16 millions counts); presets; Real Time/Live Time: 1 to 232(s), Multiples of 1 s; ADC LLD and ULD Aajustable from 0 to 100% of full scale via hardware control; input accepts positive unipolar pulses in

  3. VHDL implementation of feature-extraction algorithm for the PANDA electromagnetic calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Guliyev, E. [Kernfysisch Versneller Instituut, University of Groningen, Zernikelaan 25, NL-9747 AA Groningen (Netherlands); Kavatsyuk, M., E-mail: m.kavatsyuk@rug.nl [Kernfysisch Versneller Instituut, University of Groningen, Zernikelaan 25, NL-9747 AA Groningen (Netherlands); Lemmens, P.J.J.; Tambave, G.; Loehner, H. [Kernfysisch Versneller Instituut, University of Groningen, Zernikelaan 25, NL-9747 AA Groningen (Netherlands)

    2012-02-01

    A simple, efficient, and robust feature-extraction algorithm, developed for the digital front-end electronics of the electromagnetic calorimeter of the PANDA spectrometer at FAIR, Darmstadt, is implemented in VHDL for a commercial 16 bit 100 MHz sampling ADC. The source-code is available as an open-source project and is adaptable for other projects and sampling ADCs. Best performance with different types of signal sources can be achieved through flexible parameter selection. The on-line data-processing in FPGA enables to construct an almost dead-time free data acquisition system which is successfully evaluated as a first step towards building a complete trigger-less readout chain. Prototype setups are studied to determine the dead-time of the implemented algorithm, the rate of false triggering, timing performance, and event correlations.

  4. VHDL implementation of feature-extraction algorithm for the PANDA electromagnetic calorimeter

    International Nuclear Information System (INIS)

    Guliyev, E.; Kavatsyuk, M.; Lemmens, P.J.J.; Tambave, G.; Löhner, H.

    2012-01-01

    A simple, efficient, and robust feature-extraction algorithm, developed for the digital front-end electronics of the electromagnetic calorimeter of the PANDA spectrometer at FAIR, Darmstadt, is implemented in VHDL for a commercial 16 bit 100 MHz sampling ADC. The source-code is available as an open-source project and is adaptable for other projects and sampling ADCs. Best performance with different types of signal sources can be achieved through flexible parameter selection. The on-line data-processing in FPGA enables to construct an almost dead-time free data acquisition system which is successfully evaluated as a first step towards building a complete trigger-less readout chain. Prototype setups are studied to determine the dead-time of the implemented algorithm, the rate of false triggering, timing performance, and event correlations.

  5. Value of apparent diffusion coefficient (ADC) in evaluating response ...

    African Journals Online (AJOL)

    Objective. To determine whether the apparent diffusion coefficient (ADC) value obtained by diffusion-weighted magnetic resonance imaging (DW-MRI) can be used as a reliable detector of response of carcinoma of the cervix treated with chemoradiotherapy, compared with conventional. T2-weighted MRI. Design.

  6. Continuous time sigma delta ADC design and non-idealities analysis

    International Nuclear Information System (INIS)

    Yuan Jun; Chen Zhenhai; Yang Yintang; Zhang Zhaofeng; Wu Jun; Wang Chao; Qian Wenrong

    2011-01-01

    A wide bandwidth continuous time sigma delta ADC is implemented in 130 nm CMOS. A detailed non-idealities analysis (excess loop delay, clock jitter, finite gain and GBW, comparator offset and DAC mismatch) is performed developed in Matlab/Simulink. This design is targeted for wide bandwidth applications such as video or wireless base-stations. Athird-order continuous time sigma delta modulator comprises a third-order RC operational-amplifier-based loop filter and 3-bit internal quantizer operated at 512 MHz clock frequency. The sigma delta ADC achieves 60 dB SNR and 59.3 dB SNDR over a 16-MHz signal band at an OSR of 16. The power consumption of the CT sigma delta modulator is 22 mW from the 1.2-V supply. (semiconductor integrated circuits)

  7. Recombinant Chimpanzee Adenovirus Vaccine AdC7-M/E Protects against Zika Virus Infection and Testis Damage.

    Science.gov (United States)

    Xu, Kun; Song, Yufeng; Dai, Lianpan; Zhang, Yongli; Lu, Xuancheng; Xie, Yijia; Zhang, Hangjie; Cheng, Tao; Wang, Qihui; Huang, Qingrui; Bi, Yuhai; Liu, William J; Liu, Wenjun; Li, Xiangdong; Qin, Chuan; Shi, Yi; Yan, Jinghua; Zhou, Dongming; Gao, George F

    2018-03-15

    The recent outbreak of Zika virus (ZIKV) has emerged as a global health concern. ZIKV can persist in human semen and be transmitted by sexual contact, as well as by mosquitoes, as seen for classical arboviruses. We along with others have previously demonstrated that ZIKV infection leads to testis damage and infertility in mouse models. So far, no prophylactics or therapeutics are available; therefore, vaccine development is urgently demanded. Recombinant chimpanzee adenovirus has been explored as the preferred vaccine vector for many pathogens due to the low preexisting immunity against the vector among the human population. Here, we developed a ZIKV vaccine based on recombinant chimpanzee adenovirus type 7 (AdC7) expressing ZIKV M/E glycoproteins. A single vaccination of AdC7-M/E was sufficient to elicit potent neutralizing antibodies and protective immunity against ZIKV in both immunocompetent and immunodeficient mice. Moreover, vaccinated mice rapidly developed neutralizing antibody with high titers within 1 week postvaccination, and the elicited antiserum could cross-neutralize heterologous ZIKV strains. Additionally, ZIKV M- and E-specific T cell responses were robustly induced by AdC7-M/E. Moreover, one-dose inoculation of AdC7-M/E conferred mouse sterilizing immunity to eliminate viremia and viral burden in tissues against ZIKV challenge. Further investigations showed that vaccination with AdC7-M/E completely protected against ZIKV-induced testicular damage. These data demonstrate that AdC7-M/E is highly effective and represents a promising vaccine candidate for ZIKV control. IMPORTANCE Zika virus (ZIKV) is a pathogenic flavivirus that causes severe clinical consequences, including congenital malformations in fetuses and Guillain-Barré syndrome in adults. Vaccine development is a high priority for ZIKV control. In this study, to avoid preexisting anti-vector immunity in humans, a rare serotype chimpanzee adenovirus (AdC7) expressing the ZIKV M

  8. Design And Construction Of The 8K Multi-Channel GAMMA Spectrometer Module (AMPLIFIER+ADC+MCD)

    International Nuclear Information System (INIS)

    Truong Van Dat; Hoang Thi Ngoc Bich; Pham Ngoc Tuan; Dang Lanh; Tuong Thi Thu Huong; Vu Xuan Cach

    2007-01-01

    A multichannel pulse-height analyzer system (MCA) consists of an spectroscopy Amplifier, ADC with 8192 channel performance, a histogramming memory, and a visual display of the histogram implemented on a Personal Computer (PC). The purpose of the analog-to-digital converter (ADC) is to measure the maximum amplitude of an analog pulse, and convert that value into a digital number. This digital output is a proportional representation of the analog amplitude at the ADC input. The digital ADC outputs are stored in a histogram memory, where each bin represents a pulse height interval and the number of events in each bin represents the number of events in that interval. The combination of ADC, histogramming memory and display functions are the minimum to constitute a multichannel analyzer or MCA based on PC. It is designed and fabricated on a single NIM module. The communication between MCA module and PC implements via USB bus. In our application, performance of the USB standard version 1.1 is good enough for purposes. The application program was designed in LabWIEW 8.0 software. This application is the main display and acquisition software for the MCA module. It is compatible with Windows 98SE/XP. The libraries USB driver, with their supporting files, are in the FTD2XX driver DLL Package and D2XX function 7.0 for LabWIEW supporting. These libraries are used to write custom code to control the MCA module. (author)

  9. The PAUCam readout electronics system

    Science.gov (United States)

    Jiménez, Jorge; Illa, José M.; Cardiel-Sas, Laia; de Vicente, Juan; Castilla, Javier; Casas, Ricard

    2016-08-01

    The PAUCam is an optical camera with a wide field of view of 1 deg x 1 deg and up to 46 narrow and broad band filters. The camera is already installed on the William Herschel Telescope (WHT) in the Canary Islands, Spain and successfully commissioned during the first period of 2015. The paper presents the main results from the readout electronics commissioning tests and include an overview of the whole readout electronics system, its configuration and current performance.

  10. Readout scheme for the Baby-MIND detector

    CERN Document Server

    Noah, Etam; Cadoux, F; Favre, Y; Martinez, B; Nicola, L; Parsa, S; Rayner, M; Antonova, M; Fedotov, S; Izmaylov, A; Kleymenova, A; Khabibullin, M; Khotyantsev, A; Kudenko, Y; Likhacheva, V; Mefodiev, A; Mineev, O; Ovsiannikova, T; Shaykhiev, A; Suvorov, S; Yershov, N; Tsenov, R

    2016-01-01

    A readout scheme has been designed for the plastic scintillator bars of the Baby-MIND detector modules. This spectrometer will measure momentum and identify the charge of 1 GeV/c muons with magnetized iron plates interleaved with detector modules. One challenge the detector aims to address is that of keeping high charge identification efficiencies for momenta below 1 GeV/c where multiple scattering in the iron plates degrades momentum resolution. A front-end board has been developed, with 3 CITIROC readout chips per board and up to 96 channels. Hamamatsu MPPCs type S12571-025C photosensors were chosen for readout of wavelength shifting fibers embedded in plastic scintillators. Procurement of the MPPCs has been carried out to instrument 3000 channels in total. Design choices and first results of this readout scheme are presented.

  11. A 12-bit 40 MS/s pipelined ADC with over 80 dB SFDR

    Energy Technology Data Exchange (ETDEWEB)

    Wei Qi; Yin Xiumei; Han Dandan; Yang Huazhong, E-mail: q-wei05@mails.tsinghua.edu.c [Department of Electronic Engineering, Tsinghua University, Beijing 100084 (China)

    2010-02-15

    This paper describes a 12-bit 40 MS/s calibration-free pipelined analog-to-digital converter (ADC), which is optimized for high spurious free dynamic range (SFDR) performance and low power dissipation. With a 4.9 MHz sine wave input, the prototype ADC implemented in a 0.18-{mu}m 1P6M CMOS process shows measured differential nonlinearity and integral nonlinearity within 0.78 and 1.32 least significant bits at the 12-bit level without any trimming or calibration. The ADC, with a total die area of 3.1 x 2.1 mm{sup 2}, demonstrates a maximum signal-to-noise distortion ratio (SNDR) and SFDR of 66.32 and 83.38 dB, respectively, at a 4.9 MHz analog input and a power consumption of 102 mW from a 1.8 V supply. (semiconductor integrated circuits)

  12. Usefulness of Diffusion-Weighted MR Imaging for Breast Lesions: Comparing the Apparent Diffusion Coefficient (ADC) Values and the Pathologic Results

    International Nuclear Information System (INIS)

    Ahn, Hye Shin; Chang, Yun Woo; Choi, Kyung Hee; Kim, Hyun Joo; Hong, Seong Suk; Hwang, Jung Hwa; Kwon, Kui Hyang; Kim, Yong Bae

    2011-01-01

    We wanted to evaluate the ability of the apparent diffusion coefficient (ADC) values to differentiate between benign and malignant breast lesions and the normal breast parenchyma. We used breast MRI, including DWI, to obtain images of 167 breast lesions (18 benign lesions and 149 malignant lesions) of 152 women (mean age: 48.6 years, range: 24-80 years). The mean ADC values of the malignant lesions were compared to those of the benign lesions and the normal parenchyma. We compared the ADC values of IDC, DCIS and other types of breast cancer and we also compared the ADC values with the nuclear grade of IDC. The mean ADC values of the malignant lesions were lower than those of the benign lesions and the normal parenchyma (p -3 mm 2 /s for discriminating between malignant and benign lesion showed a specificity of 53% and a sensitivity of 100%, and the ADC threshold value of 1.33 X 10 -3 mm 2 /s showed a specificity of 93% and a sensitivity of 94% for discriminating between malignant and benign lesion.

  13. Rutherford X-ray spectrometer readout

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1978-07-01

    Rutherford electronic X-ray spectrometer readout is based on the combination of two established techniques (a) the detection and location of soft X-rays by means of multichannel electron multiplier arrays (MCP's), and (b) the electronic readout of charge distributions (generally in multi-wire proportional counters) by means of the delay line techniques. In order for the latter device to function well a charge signal of approximately 10 6 electrons must be available to the delay line wand. This is achieved in the present device by means of two cascaded MCP's which can produce electron gains up to approximately 10 8 , and so operate the delay line from the single electron pulses generated at the front face of an MCP by a soft X-ray. The delay line readout technique was chosen because of its simplicity (both in terms of the necessary hardware and the associated electronics), robustness, and ease of implementation. In order to achieve the target spatial resolution of 50 μm (fwhm) or 20 μm (standard deviation) it was necessary to adapt the charge collection system so that the readout takes place from a length of delay line 200 mm long. The general layout of the system and the functions of the electronic circuits are described. Performance testing, setting up procedures and trouble shooting of the system are discussed. (U.K.)

  14. Two zinc-binding domains in the transporter AdcA from Streptococcus pyogenes facilitate high-affinity binding and fast transport of zinc.

    Science.gov (United States)

    Cao, Kun; Li, Nan; Wang, Hongcui; Cao, Xin; He, Jiaojiao; Zhang, Bing; He, Qing-Yu; Zhang, Gong; Sun, Xuesong

    2018-04-20

    Zinc is an essential metal in bacteria. One important bacterial zinc transporter is AdcA, and most bacteria possess AdcA homologs that are single-domain small proteins due to better efficiency of protein biogenesis. However, a double-domain AdcA with two zinc-binding sites is significantly overrepresented in Streptococcus species, many of which are major human pathogens. Using molecular simulation and experimental validations of AdcA from Streptococcus pyogenes , we found here that the two AdcA domains sequentially stabilize the structure upon zinc binding, indicating an organization required for both increased zinc affinity and transfer speed. This structural organization appears to endow Streptococcus species with distinct advantages in zinc-depleted environments, which would not be achieved by each single AdcA domain alone. This enhanced zinc transport mechanism sheds light on the significance of the evolution of the AdcA domain fusion, provides new insights into double-domain transporter proteins with two binding sites for the same ion, and indicates a potential target of antimicrobial drugs against pathogenic Streptococcus species. © 2018 by The American Society for Biochemistry and Molecular Biology, Inc.

  15. [The relevance of ADC value, T₁intensive rate and the clinical activities in ankylosing spondylitis sacroiliitis].

    Science.gov (United States)

    Zhao, Yinghua; Han, Xinai; Hu, Shaoyong; Shi, Xingliang; Zhao, Jing; Sun, Erwei; Li, Shaolin

    2014-09-23

    To evaluate the value of judging for the activity in AS by diffusion-weighted sequences (DWI) and enhance sequences MRI(DCE-MRI), to explore the correlation of Apparent diffusion coefficient(ADC) values, intensive rate and the clinical activity index in sacroiliitis (SIJ) of ankylosing spondylitis (AS). 56 patients prospectively choiced and diagnosed were divided into two groupsas, active group (n = 32) and chronic group (n = 24) by rheumatologist according to BASDAI and laboratory parameters. Twenty healthy adults were as control group. The values of ADC and intensive rate of all sacroiliac joints (SIJs) were measured on MRI. BASDAI score were got by Bath ankylosing spondylitis disease activity index. ESR, CPR and were got by laboratory. Statisticaly to analysis whether the parameters were significantly different amang AS active, chronic, and the control group. To assess the correlation of the values of ADC, intensive rate and BASDAI score, ESR, CPR and in SIJ. the values of ADC and intensive rate were significantly different among AS active, chronic and the control group. There were the significant correlation between the values of ADC, intensive rate and BASDAI score. Diffusion-weighted sequences and Contrast-enhanced sequences is superior to other methods in judging the activity in AS.combined with clinical activity index, the accuracy can significantly be improved to explore whether the activities of AS are.

  16. Investigation of image distortion due to MCP electronic readout misalignment and correction via customized GUI application

    Science.gov (United States)

    Vitucci, G.; Minniti, T.; Tremsin, A. S.; Kockelmann, W.; Gorini, G.

    2018-04-01

    The MCP-based neutron counting detector is a novel device that allows high spatial resolution and time-resolved neutron radiography and tomography with epithermal, thermal and cold neutrons. Time resolution is possible by the high readout speeds of ~ 1200 frames/sec, allowing high resolution event counting with relatively high rates without spatial resolution degradation due to event overlaps. The electronic readout is based on a Timepix sensor, a CMOS pixel readout chip developed at CERN. Currently, a geometry of a quad Timepix detector is used with an active format of 28 × 28 mm2 limited by the size of the Timepix quad (2 × 2 chips) readout. Measurements of a set of high-precision micrometers test samples have been performed at the Imaging and Materials Science & Engineering (IMAT) beamline operating at the ISIS spallation neutron source (U.K.). The aim of these experiments was the full characterization of the chip misalignment and of the gaps between each pad in the quad Timepix sensor. Such misalignment causes distortions of the recorded shape of the sample analyzed. We present in this work a post-processing image procedure that considers and corrects these effects. Results of the correction will be discussed and the efficacy of this method evaluated.

  17. Relativistic rise measurements with very fine sampling intervals

    International Nuclear Information System (INIS)

    Ludlam, T.; Platner, E.D.; Polychronakos, V.A.; Lindenbaum, S.J.; Kramer, M.A.; Teramoto, Y.

    1980-01-01

    The motivation of this work was to determine whether the technique of charged particle identification via the relativistic rise in the ionization loss can be significantly improved by virtue of very small sampling intervals. A fast-sampling ADC and a longitudinal drift geometry were used to provide a large number of samples from a single drift chamber gap, achieving sampling intervals roughly 10 times smaller than any previous study. A single layer drift chamber was used, and tracks of 1 meter length were simulated by combining together samples from many identified particles in this detector. These data were used to study the resolving power for particle identification as a function of sample size, averaging technique, and the number of discrimination levels (ADC bits) used for pulse height measurements

  18. ADC histogram analysis of muscle lymphoma - Correlation with histopathology in a rare entity.

    Science.gov (United States)

    Meyer, Hans-Jonas; Pazaitis, Nikolaos; Surov, Alexey

    2018-06-21

    Diffusion weighted imaging (DWI) is able to reflect histopathology architecture. A novel imaging approach, namely histogram analysis, is used to further characterize lesion on MRI. The purpose of this study is to correlate histogram parameters derived from apparent diffusion coefficient- (ADC) maps with histopathology parameters in muscle lymphoma. Eight patients (mean age 64.8 years, range 45-72 years) with histopathologically confirmed muscle lymphoma were retrospectively identified. Cell count, total nucleic and average nucleic areas were estimated using ImageJ. Additionally, Ki67-index was calculated. DWI was obtained on a 1.5T scanner by using the b values of 0 and 1000 s/mm2. Histogram analysis was performed as a whole lesion measurement by using a custom-made Matlabbased application. The correlation analysis revealed statistically significant correlation between cell count and ADCmean (p=-0.76, P=0.03) as well with ADCp75 (p=-0.79, P=0.02). Kurtosis and entropy correlated with average nucleic area (p=-0.81, P=0.02, p=0.88, P=0.007, respectively). None of the analyzed ADC parameters correlated with total nucleic area and with Ki67-index. This study identified significant correlations between cellularity and histogram parameters derived from ADC maps in muscle lymphoma. Thus, histogram analysis parameters reflect histopathology in muscle tumors. Advances in knowledge: Whole lesion ADC histogram analysis is able to reflect histopathology parameters in muscle lymphomas.

  19. Combined apparent diffusion coefficient value (ADC and 1H magnetic resonance spectroscopy (MRS in breast lesions: Benefits and limitations

    Directory of Open Access Journals (Sweden)

    Enass M. Khattab

    2018-06-01

    Conclusion: A great advantage of ADC value is the significant difference between benign and malignant lesions, because of this it plays an important role in characterization of breast lesions. MRS is the only in vivo technique which can detect tissue metabolites. In our study combined MRS with ADC value increased sensitivity in detecting lesions, while the specificity remained at lower level than that of the ADC value alone.

  20. Diagnosis of early sacroiliitis in seronegative spondyloarthropathies by DWI and correlation of clinical and laboratory findings with ADC values

    Energy Technology Data Exchange (ETDEWEB)

    Gezmis, Esin; Donmez, Fuldem Y., E-mail: fuldemyildirim@yahoo.com; Agildere, Muhtesem

    2013-12-01

    Purpose: Sacroiliitis is one of the diagnostic criteria of seronegative SpA. The purpose of our study is to show the signal characteristics of the sacral and iliac surfaces by DWI which may contribute in early diagnosis of sacroiliitis and investigate the correlation between ADC values and clinical and laboratory parameters. Materials and methods: 62 patients with inflammatory low back pain, with a history or suspect of seronegative SpA are enrolled into the study. 40 age and sex-matched subjects without SpA constituted the control group. After obtaining routine T1 and T2 weighted sequences, echo planar imaging at b values of 0, 400 and 800 was performed. ADC values on both surfaces of the both sacroiliac joints were measured in all subjects. The CRP and sedimentation results and the presence of arthritis and enthesitis were also correlated with the ADC values. Results: ADC values on both surfaces of the both sacroiliac joints were found 0.23 × 10{sup −3} mm{sup 2}/sn in the control group. In the patient group, mean ADC value of 0.48 × 10{sup −3} mm{sup 2}/sn was obtained (p < 0.001), which was statistically significant, compatible with the increased diffusion due to medullary edema in early sacroiliitis. There was a slight correlation between CRP and ADC values; presumed to be showing the relation between the activity of the disease and the active inflammation on DWI. There was no correlation between arthritis and enthesitis and the ADC values (p > 0.001). Conclusion: DWI, by measuring ADC values, adds significant information in the early diagnosis of sacroiliitis and may help to evaluate the efficiency of the treatment.

  1. On the design of high-speed energy-efficient successive-approximation logic for asynchronous SAR ADCs

    Science.gov (United States)

    Yang, Jiaqi; Li, Ting; Yu, Mingyuan; Zhang, Shuangshuang; Lin, Fujiang; He, Lin

    2017-08-01

    This paper analyzes the power consumption and delay mechanisms of the successive-approximation (SA) logic of a typical asynchronous SAR ADC, and provides strategies to reduce both of them. Following these strategies, a unique direct-pass SA logic is proposed based on a full-swing once-triggered DFF and a self-locking tri-state gate. The unnecessary internal switching power of a typical TSPC DFF, which is commonly used in the SA logic, is avoided. The delay of the ready detector as well as the sequencer is removed from the critical path. A prototype SAR ADC based on the proposed SA logic is fabricated in 130 nm CMOS. It achieves a peak SNDR of 56.3 dB at 1.2 V supply and 65 MS/s sampling rate, and has a total power consumption of 555 μW, while the digital part consumes only 203 μW. Project supported by the National Natural Science Foundation of China (Nos. 61204033, 61331015), the Fundamental Research Funds for the Central Universities (No. WK2100230015), and the Funds of Science and Technology on Analog Integrated Circuit Laboratory (No. 9140C090111150C09041).

  2. D-Zero muon readout electronics design

    International Nuclear Information System (INIS)

    Baldin, B.; Hansen, S.; Los, S.; Matveev, M.; Vaniev, V.

    1996-11-01

    The readout electronics designed for the D null Muon Upgrade are described. These electronics serve three detector subsystems and one trigger system. The front-ends and readout hardware are synchronized by means of timing signals broadcast from the D null Trigger Framework. The front-end electronics have continuously running digitizers and two levels of buffering resulting in nearly deadtimeless operation. The raw data is corrected and formatted by 16- bit fixed point DSP processors. These processors also perform control of the data buffering. The data transfer from the front-end electronics located on the detector platform is performed by serial links running at 160 Mbit/s. The design and test results of the subsystem readout electronics and system interface are discussed

  3. Quantitative diffusion tensor MR imaging of the brain: field strength related variance of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) scalars

    International Nuclear Information System (INIS)

    Huisman, Thierry A.G.M.; Loenneker, Thomas; Barta, Gerd; Bellemann, Matthias E.; Hennig, Juergen; Fischer, Joachim E.; Il'yasov, Kamil A.

    2006-01-01

    The objectives were to study the ''impact'' of the magnetic field strength on diffusion tensor imaging (DTI) metrics and also to determine whether magnetic-field-related differences in T2-relaxation times of brain tissue influence DTI measurements. DTI was performed on 12 healthy volunteers at 1.5 and 3.0 Tesla (within 2 h) using identical DTI scan parameters. Apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values were measured at multiple gray and white matter locations. ADC and FA values were compared and analyzed for statistically significant differences. In addition, DTI measurements were performed at different echo times (TE) for both field strengths. ADC values for gray and white matter were statistically significantly lower at 3.0 Tesla compared with 1.5 Tesla (% change between -1.94% and -9.79%). FA values were statistically significantly higher at 3.0 Tesla compared with 1.5 Tesla (% change between +4.04 and 11.15%). ADC and FA values are not significantly different for TE=91 ms and TE=125 ms. Thus, ADC and FA values vary with the used field strength. Comparative clinical studies using ADC or FA values should consequently compare ADC or FA results with normative ADC or FA values that have been determined for the field strength used. (orig.)

  4. Design of eight-channel ADC card for GHz signal conversion

    CERN Document Server

    Habib, Samer Bou; Jalmuzna, Wojciech; Jezynski, Tomasz

    2011-01-01

    This paper describes the design of an eight-channel ATCA card suited for direct analog-to-digital conversion of 1.3 GHz signals with a maximum ADC clock frequency of 500 MHz. The undersampling operation is used for signal conversion. This card was designed for the needs of the LLRF system of the FLASH and XFEL accelerators. The designed module consists of a main ATCA board with eight ADCs, FPGA unit, memory, power supply and diagnostic circuits. The main ATCA card allows connecting a daughter board with IPMI, CPU and fast interfaces for communication purposes. This paper describes such issues as system organization allowing acquisition of data at such high data rates, circuit synchronization by high-quality clock signals, CPU and connectivity features, 20-layer PCB design and techniques used for high-frequency signals transmission and matching.

  5. Utility of DWI with quantitative ADC values in ovarian tumors: a meta-analysis of diagnostic test performance.

    Science.gov (United States)

    Pi, Shan; Cao, Rong; Qiang, Jin Wei; Guo, Yan Hui

    2018-01-01

    Background Diffusion-weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) values are widely used in the differential diagnosis of ovarian tumors. Purpose To assess the diagnostic performance of quantitative ADC values in ovarian tumors. Material and Methods PubMed, Embase, the Cochrane Library, and local databases were searched for studies assessing ovarian tumors using quantitative ADC values. We quantitatively analyzed the diagnostic performances for two clinical problems: benign vs. malignant tumors and borderline vs. malignant tumors. We evaluated diagnostic performances by the pooled sensitivity and specificity values and by summary receiver operating characteristic (SROC) curves. Subgroup analyses were used to analyze study heterogeneity. Results From the 742 studies identified in the search results, 16 studies met our inclusion criteria. A total of ten studies evaluated malignant vs. benign ovarian tumors and six studies assessed malignant vs. borderline ovarian tumors. Regarding the diagnostic accuracy of quantitative ADC values for distinguishing between malignant and benign ovarian tumors, the pooled sensitivity and specificity values were 0.91 and 0.91, respectively. The area under the SROC curve (AUC) was 0.96. For differentiating borderline from malignant tumors, the pooled sensitivity and specificity values were 0.89 and 0.79, and the AUC was 0.91. The methodological quality of the included studies was moderate. Conclusion Quantitative ADC values could serve as useful preoperative markers for predicting the nature of ovarian tumors. Nevertheless, prospective trials focused on standardized imaging parameters are needed to evaluate the clinical value of quantitative ADC values in ovarian tumors.

  6. Position readout by charge division in large two-dimensional detectors

    International Nuclear Information System (INIS)

    Alberi, J.L.

    1976-10-01

    The improvement in readout spatial resolution for charge division systems with subdivided readout electrodes has been analyzed. This readout forms the position and sum signals by a linear, unambiguous analogue summation technique. It is shown that the readout resolution is a function of only electrode capacitance and shaping parameters. The line width improves as 1/N/sup 1 / 2 /, where N is the number of electrode subdivisions

  7. Optimization of Modulator and Circuits for Low Power Continuous-Time Delta-Sigma ADC

    DEFF Research Database (Denmark)

    Marker-Villumsen, Niels; Bruun, Erik

    2014-01-01

    This paper presents a new optimization method for achieving a minimum current consumption in a continuous-time Delta-Sigma analog-to-digital converter (ADC). The method is applied to a continuous-time modulator realised with active-RC integrators and with a folded-cascode operational transconduc...... levels are swept. Based on the results of the circuit analysis, for each modulator combination the summed current consumption of the 1st integrator and quantizer of the ADC is determined. By also sweeping the partitioning of the noise power for the different circuit parts, the optimum modulator...

  8. Design and Performance of the CMS Pixel Detector Readout Chip

    CERN Document Server

    Kästli, H C; Erdmann, W; Hörmann, C; Horisberger, R P; Kotlinski, D; Meier, B; Hoermann, Ch.

    2006-01-01

    The readout chip for the CMS pixel detector has to deal with an enormous data rate. On-chip zero suppression is inevitable and hit data must be buffered locally during the latency of the first level trigger. Dead-time must be kept at a minimum. It is dominated by contributions coming from the readout. To keep it low an analog readout scheme has been adopted where pixel addresses are analog coded. We present the architecture of the final CMS pixel detector readout chip with special emphasis on the analog readout chain. Measurements of its performance are discussed.

  9. Low Power 2-Bit ADC Array with Serial Output, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Microwave interferometers for NASA missions such as PATH employ the GeoSTAR instrument, consisting of 600 receivers. Each receiver requires I and Q ADCs...

  10. The readout system of the new H1 silicon detectors

    International Nuclear Information System (INIS)

    Buerger, J.; Hansen, K.; Lange, W.; Prell, S.; Zimmermann, W.; Henschel, H.; Haynes, W.J.; Noyes, G.W.; Joensson, L.; Gabathuler, K.; Horisberger, R.; Wagener, M.; Eichler, R.; Erdmann, W.; Niggli, H.; Pitzl, D.

    1995-03-01

    The H1 detector at HERA at DESY undergoes presently a major upgrade. In this context silicon strip detectors have been installed at beginning of 1995. The high bunch crossing frequency of HERA (10.4 MHz) demands a novel readout architecture which includes pipelining, signal processing and data reduction at a very early stage. The front end readout is hierarchically organized. The detector elements are read out by the APC chip which contains an analog pipeline and performs first background subtraction. Up to five readout chips are controlled by a Decoder Chip. The readout processor module (OnSiRoC) operates the detectors, controls the Decoder Chips and performs a first level data reduction. The paper describes the readout architecture of the H1 Silicon Detectors and performance data of the complete readout chain. (orig.)

  11. Hybrid CMOS-Graphene Sensor Array for Subsecond Dopamine Detection.

    Science.gov (United States)

    Nasri, Bayan; Wu, Ting; Alharbi, Abdullah; You, Kae-Dyi; Gupta, Mayank; Sebastian, Sunit P; Kiani, Roozbeh; Shahrjerdi, Davood

    2017-12-01

    We introduce a hybrid CMOS-graphene sensor array for subsecond measurement of dopamine via fast-scan cyclic voltammetry (FSCV). The prototype chip has four independent CMOS readout channels, fabricated in a 65-nm process. Using planar multilayer graphene as biologically compatible sensing material enables integration of miniaturized sensing electrodes directly above the readout channels. Taking advantage of the chemical specificity of FSCV, we introduce a region of interest technique, which subtracts a large portion of the background current using a programmable low-noise constant current at about the redox potentials. We demonstrate the utility of this feature for enhancing the sensitivity by measuring the sensor response to a known dopamine concentration in vitro at three different scan rates. This strategy further allows us to significantly reduce the dynamic range requirements of the analog-to-digital converter (ADC) without compromising the measurement accuracy. We show that an integrating dual-slope ADC is adequate for digitizing the background-subtracted current. The ADC operates at a sampling frequency of 5-10 kHz and has an effective resolution of about 60 pA, which corresponds to a theoretical dopamine detection limit of about 6 nM. Our hybrid sensing platform offers an effective solution for implementing next-generation FSCV devices that can enable precise recording of dopamine signaling in vivo on a large scale.

  12. Hybrid amplifier for calorimetry with photodiode readout

    Energy Technology Data Exchange (ETDEWEB)

    Sushkov, V V

    1994-12-31

    A hybrid surface mounted amplifier for the photodiode readout of the EM calorimeter has been developed. The main technical characteristics of the design are presented. The design able to math readout constraints for a high luminosity collider experiment is discussed. 10 refs., 2 tabs., 8 figs.

  13. A Novel Two-Wire Fast Readout Approach for Suppressing Cable Crosstalk in a Tactile Resistive Sensor Array.

    Science.gov (United States)

    Wu, Jianfeng; Wang, Yu; Li, Jianqing; Song, Aiguo

    2016-05-18

    For suppressing the crosstalk problem due to wire resistances and contacted resistances of the long flexible cables in tactile sensing systems, we present a novel two-wire fast readout approach for the two-dimensional resistive sensor array in shared row-column fashion. In the approach, two wires are used for every driving electrode and every sampling electrode in the resistive sensor array. The approach with a high readout rate, though it requires a large number of wires and many sampling channels, solves the cable crosstalk problem. We also verified the approach's performance with Multisim simulations and actual experiments.

  14. A Novel Two-Wire Fast Readout Approach for Suppressing Cable Crosstalk in a Tactile Resistive Sensor Array

    Directory of Open Access Journals (Sweden)

    Jianfeng Wu

    2016-05-01

    Full Text Available For suppressing the crosstalk problem due to wire resistances and contacted resistances of the long flexible cables in tactile sensing systems, we present a novel two-wire fast readout approach for the two-dimensional resistive sensor array in shared row-column fashion. In the approach, two wires are used for every driving electrode and every sampling electrode in the resistive sensor array. The approach with a high readout rate, though it requires a large number of wires and many sampling channels, solves the cable crosstalk problem. We also verified the approach’s performance with Multisim simulations and actual experiments.

  15. 100 Gbps PCI-Express readout for the LHCb upgrade

    International Nuclear Information System (INIS)

    Durante, P.; Neufeld, N.; Schwemmer, R.; Balbi, G.; Marconi, U.

    2015-01-01

    We present a new data acquisition system under development for the next upgrade of the LHCb experiment at CERN. We focus in particular on the design of a new generation of readout boards, the PCIe40, and on the viability of PCI-Express as an interconnect technology for high speed readout. We show throughput measurements across the PCI-Express bus, on Altera Stratix 5 devices, using a DMA mechanism and different synchronization schemes between the FPGA and the readout unit. Finally we discuss hardware and software design considerations necessary to achieve a data throughput of 100 Gbps in the final readout board

  16. A 64-channel readout ASIC for nanowire biosensor array with electrical calibration scheme.

    Science.gov (United States)

    Chai, Kevin T C; Choe, Kunil; Bernal, Olivier D; Gopalakrishnan, Pradeep K; Zhang, Guo-Jun; Kang, Tae Goo; Je, Minkyu

    2010-01-01

    A 1.8-mW, 18.5-mm(2) 64-channel current readout ASIC was implemented in 0.18-µm CMOS together with a new calibration scheme for silicon nanowire biosensor arrays. The ASIC consists of 64 channels of dedicated readout and conditioning circuits which incorporate correlated double sampling scheme to reduce the effect of 1/f noise and offset from the analog front-end. The ASIC provides a 10-bit digital output with a sampling rate of 300 S/s whilst achieving a minimum resolution of 7 pA(rms). A new electrical calibration method was introduced to mitigate the issue of large variations in the nano-scale sensor device parameters and optimize the sensor sensitivity. The experimental results show that the proposed calibration technique improved the sensitivity by 2 to 10 times and reduced the variation between dataset by 9 times.

  17. Application of porous-media theory to the investigation of water ADC changes in rabbit Achilles tendon caused by tensile loading

    Science.gov (United States)

    Wellen, J.; Helmer, K. G.; Grigg, P.; Sotak, C. H.

    2004-09-01

    The water apparent diffusion coefficient (ADC) in rabbit Achilles tendon is anisotropic, diffusion-time dependent, and changes as a function of tensile load. Water ADC changes of tendon under mechanical load are thought to be due to the extrusion of water from the more restricted tendon core to a relatively unrestricted bulk phase at the periphery (rim) of the tendon. Tensile loading may influence water ADC values by changing the spatial separation of restricting barriers (e.g., increasing the tendon fibril packing density). To explore this issue, we have applied porous-media theory to the investigation of water ADC changes in rabbit Achilles tendon under two different mechanical loading conditions (a baseline condition with a minimal tensile stress and a second in which the tensile stress was approximately 1 MPa). Diffusion sensitivity was applied in directions parallel and perpendicular to the long axis of the tendon. The short diffusion-time behavior of the resulting time-dependent ADC curves was used to indirectly infer information regarding the average surface area to volume ratio of the space available for molecular diffusion. From these values, we estimated a 40% reduction in volume available for diffusion in the perpendicular direction after tensile loading, but only a 10% reduction in the parallel direction. These differences are consistent with the known geometry of the tendon microstructure and suggest an increase in fibril packing density upon loading. The long diffusion-time behavior of the time-dependent ADC curves was used to indirectly infer the tortuosity of the diffusion pathways through the interstitial space. The tortuosity in the direction perpendicular to the tendon long axis was approximately 2.5 times greater than that in the parallel direction. Stimulated-echo measurement of the ADC values at longer diffusion times resulted in T1 spin editing of water with shorter T1 values (and correspondingly lower ADC values). The resulting increase in

  18. Studying DAC capacitor-array degradation in charge-redistribution SAR ADCs

    NARCIS (Netherlands)

    Khan, M.A.; Kerkhoff, Hans G.

    2014-01-01

    In this paper, system-level behavioural models are used to simulate the aging-related degradation effects in the DAC capacitor array of a charge-redistribution successive approximation register (SAR) ADC because of the large calculation time of transistor-level aging simulators. A

  19. Low Power 1-Bit ADC Array with Serial Output, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Microwave interferometers for NASA missions such as PATH and SCLP consist of up to 900 receivers. Each receiver requires I and Q ADCs (analog-to-digital converters)...

  20. NRL 12-Bit, 213 Msps ADC HSAD9 MCM Evaluation Board

    National Research Council Canada - National Science Library

    Thai, Khanh

    1999-01-01

    The MCM Evaluation Board is a 6" by 6" test fixture designed for evaluating the HSAD9 MCM, a completely self contained ADC multichip module that digitizes incoming differential analog signals to 12...

  1. A second-order ΣΔ ADC using sputtered IGZO TFTs

    CERN Document Server

    Correia, Ana Paula Pinto; Goes, João Carlos da Palma

    2016-01-01

    This book discusses the design, electrical simulation and layout of a 2nd-order ∑∆ analog-to-digital converter (ADC), using oxide thin-film transistors (TFTs) technology. The authors provide a unified view of materials science and electronics engineering, in order to guide readers from both fields through key topics. To accomplish this goal, background regarding materials, device physics, characterization techniques, circuit design and layout is given together with a detailed discussion of experimental data. The final simulation results clearly demonstrate the potential of the proposed circuit-level techniques, which enables the implementation of robust and energy efficient ADCs based on oxide TFTs, for moderate resolutions and conversion-rates. Combines materials science and electronics engineering in the same book, making it possible to obtain a general overview, from TFTs production and characterization to their integration in relatively complex circuits; Adapts an a-Si:H TFT RPI model to simulate the ...

  2. HARP: high-pressure argon readout for calorimeters

    International Nuclear Information System (INIS)

    Barranco-Luque, M.; Fabjan, C.W.; Frandsen, P.K.

    1982-01-01

    Steel tubes of approximately 8 mm O.D., filled with Argon gas to approx. 200 bar, are considered as the active element for a charge collecting sampling calorimeter readout system. The tubes are permanently sealed and operated in the ion chamber mode, with the charge collection on a one-millimeter concentric anode. We present the motivation for such a device, including Monte Carlo predictions of performance. The method of construction and signal collection are discussed, with initial results on leakage and ageing of the filling gas. A prototype electromagnetic calorimeter is described

  3. A Fastbus-based silicon strip readout system

    International Nuclear Information System (INIS)

    Neoustroev, P.; Stepanov, V.; Svoiski, M.; Uvarov, L.; Matthew, P.; Russ, J.; Cooper, P.

    1995-01-01

    The readout system we describe here is built specifically to work with the LBL-designed SVX chip. It is typical of systems using a master sequencer module to direct the trigger and readout cycles of the sparse data source and to push data into a digitization and storage module. (orig.)

  4. Attitude Determination and Control Subsystem (ADCS) Preparations for the EPOXI Flyby of Comet Hartley 2

    Science.gov (United States)

    Luna, Michael E.; Collins, Steven M.

    2011-01-01

    On November 4, 2010 the former "Deep Impact" spacecraft, renamed "EPOXI" for its extended mission, flew within 700km of comet 103P/Hartley 2. In July 2005, the spacecraft had previously imaged a probe impact of comet Tempel 1. The EPOXI flyby was the fifth close encounter of a spacecraft with a comet nucleus and marked the first time in history that two comet nuclei were imaged at close range with the same suite of onboard science instruments. This challenging objective made the function of the attitude determination and control subsystem (ADCS) critical to the successful execution of the EPOXI flyby.As part of the spacecraft flyby preparations, the ADCS operations team had to perform meticulous sequence reviews, implement complex spacecraft engineering and science activities and perform numerous onboard calibrations. ADCS contributions included design and execution of 10 trajectory correction maneuvers, the science calibration of the two telescopic instruments, an in-flight demonstration of high-rate turns between Earth and comet point, and an ongoing assessment of reaction wheel health. The ADCS team was also responsible for command sequences that included updates to the onboard ephemeris and sun sensor coefficients and implementation of reaction wheel assembly (RWA) de-saturations.

  5. An ADC-free adaptive interface circuit of resistive sensor for electronic nose system.

    Science.gov (United States)

    Chang, Chia-Lin; Chiu, Shih-Wen; Tang, Kea-Tiong

    2013-01-01

    The initial resistance of chemiresistive gas sensors could be affected by temperature, humidity, and background odors. In a sensing system, the traditional interface circuit always requires an ADC to convert analog signal to digital signal. In this paper, we propose an ADC-free adaptive interface circuit for a resistive gas sensor to read sensor signal and cancel the baseline drift. Furthermore, methanol was used to test the proposed interface circuit, which was connected with a FIGARO® gas sensor. This circuit was fabricated by TSMC 0.18 µm CMOS process, and consumed 86.41 µW under 1 V supply voltage.

  6. High precision 16K, 16 channel peak sensing CAMAC ADC

    International Nuclear Information System (INIS)

    Jain, Mamta; Subramaniam, E.T

    2013-01-01

    A high density, peak sensing, analog to digital converter (ADC) double width module with CAMAC back plane has been developed for nuclear physics experiments with a large number of detectors. This module has sixteen independent channels in plug-in daughter card mother board mode

  7. Whole-lesion ADC histogram and texture analysis in predicting recurrence of cervical cancer treated with CCRT.

    Science.gov (United States)

    Meng, Jie; Zhu, Lijing; Zhu, Li; Xie, Li; Wang, Huanhuan; Liu, Song; Yan, Jing; Liu, Baorui; Guan, Yue; He, Jian; Ge, Yun; Zhou, Zhengyang; Yang, Xiaofeng

    2017-11-03

    To explore the value of whole-lesion apparent diffusion coefficient (ADC) histogram and texture analysis in predicting tumor recurrence of advanced cervical cancer treated with concurrent chemo-radiotherapy (CCRT). 36 women with pathologically confirmed advanced cervical squamous carcinomas were enrolled in this prospective study. 3.0 T pelvic MR examinations including diffusion weighted imaging (b = 0, 800 s/mm 2 ) were performed before CCRT (pre-CCRT) and at the end of 2nd week of CCRT (mid-CCRT). ADC histogram and texture features were derived from the whole volume of cervical cancers. With a mean follow-up of 25 months (range, 11 ∼ 43), 10/36 (27.8%) patients ended with recurrence. Pre-CCRT 75th, 90th, correlation, autocorrelation and mid-CCRT ADC mean , 10th, 25th, 50th, 75th, 90th, autocorrelation can effectively differentiate the recurrence from nonrecurrence group with area under the curve ranging from 0.742 to 0.850 (P values range, 0.001 ∼ 0.038). Pre- and mid-treatment whole-lesion ADC histogram and texture analysis hold great potential in predicting tumor recurrence of advanced cervical cancer treated with CCRT.

  8. Design and Simulation of a 6-Bit Successive-Approximation ADC Using Modeled Organic Thin-Film Transistors

    Directory of Open Access Journals (Sweden)

    Huyen Thanh Pham

    2016-01-01

    Full Text Available We have demonstrated a method for using proper models of pentacene P-channel and fullerene N-channel thin-film transistors (TFTs in order to design and simulate organic integrated circuits. Initially, the transistors were fabricated, and we measured their main physical and electrical parameters. Then, these organic TFTs (OTFTs were modeled with support of an organic process design kit (OPDK added in Cadence. The key specifications of the modeled elements were extracted from measured data, whereas the fitting ones were elected to replicate experimental curves. The simulating process proves that frequency responses of the TFTs cover all biosignal frequency ranges; hence, it is reasonable to deploy the elements to design integrated circuits used in biomedical applications. Complying with complementary rules, the organic circuits work properly, including logic gates, flip-flops, comparators, and analog-to-digital converters (ADCs as well. The proposed successive-approximation-register (SAR ADC consumes a power of 883.7 µW and achieves an ENOB of 5.05 bits, a SNR of 32.17 dB at a supply voltage of 10 V, and a sampling frequency of about 2 KHz.

  9. Frequency-chirped readout of spatial-spectral absorption features

    International Nuclear Information System (INIS)

    Chang, Tiejun; Mohan, R. Krishna; Harris, Todd L.; Merkel, Kristian D.; Tian Mingzhen; Babbitt, Wm. Randall

    2004-01-01

    This paper examines the physical mechanisms of reading out spatial-spectral absorption features in an inhomogeneously broadened medium using linear frequency-chirped electric fields. A Maxwell-Bloch model using numerical calculation for angled beams with arbitrary phase modulation is used to simulate the chirped field readout process. The simulation results indicate that any spatial-spectral absorption feature can be read out with a chirped field with the appropriate bandwidth, duration, and intensity. Mapping spectral absorption features into temporal intensity modulations depends on the chirp rate of the field. However, when probing a spatial-spectral grating with a chirped field, a beat signal representing the grating period can be created by interfering the emitted photon echo chirped field with a reference chirped field, regardless of the chirp rate. Comparisons are made between collinear and angled readout configurations. Readout signal strength and spurious signal distortions are investigated as functions of the grating strength and the Rabi frequency of the readout pulse. Using a collinear readout geometry, distortions from optical nutation on the transmitted field and higher-order harmonics are observed, both of which are avoided in an angled beam geometry

  10. A Novel Digital Background Calibration Technique for 16 bit SHA-less Multibit Pipelined ADC

    Directory of Open Access Journals (Sweden)

    Swina Narula

    2016-01-01

    Full Text Available In this paper, a high resolution of 16 bit and high speed of 125MS/s, multibit Pipelined ADC with digital background calibration is presented. In order to achieve low power, SHA-less front end is used with multibit stages. The first and second stages are used here as a 3.5 bit and the stages from third to seventh are of 2.5 bit and last stage is of 3-bit flash ADC. After bit alignment and truncation of total 19 bits, 16 bits are used as final digital output. To precise the remove linear gain error of the residue amplifier and capacitor mismatching error, a digital background calibration technique is used, which is a combination of signal dependent dithering (SDD and butterfly shuffler. To improve settling time of residue amplifier, a special circuit of voltage separation is used. With the proposed digital background calibration technique, the spurious-free dynamic range (SFDR has been improved to 97.74 dB @30 MHz and 88.9 dB @150 MHz, and the signal-to-noise and distortion ratio (SNDR has been improved to 79.77 dB @ 30 MHz, and 73.5 dB @ 150 MHz. The implementation of the Pipelined ADC has been completed with technology parameters of 0.18μm CMOS process with 1.8 V supply. Total power consumption is 300 mW by the proposed ADC.

  11. The correlation between biological activity and diffusion-weighted MR imaging and ADC value in cases with prostate cancer

    Directory of Open Access Journals (Sweden)

    Bedriye Koyuncu Sokmen

    2017-12-01

    Full Text Available Purpose: Firstly, we aimed to investigate the correlation among dynamic contrasted magnetic resonance (MR images, diffusion-weighted MR images, and apparent diffusion coefficent (ADC values in patients with prostate cancer. Secondly, we aimed to investigate the roles of these variables on clinical risk classification and the biological behavior of the prostate cancer. Methods: A total of sixty with prostatic adenocarcinoma patients diagnosed between January 2011 and May 2013 were retrospectively included in the study. Risk classification of patients were evaluated as low-risk (Group 1 (n = 20 (Stage T1c-T2a, PSA T3a, PSA > 20 ng/ml, Gleason Score > 7. Diffusion-weighted MR images, dynamic contrasted MR images, and ADC values of the prostates were correlated. Results: ADC values of the cases in Group 3 were lower than those of the other groups (p 0.05. Biological activity of the tumor tissue was determined by GS, while a negative correlation was observed between GSs and ADC values of the patients, (p < 0.001. Conclusion: In tumors with higher Gleason scores, lower ADC values were obtained. These measured values can play a role in the noninvasive determination of the cellularity of the tumoral mass.

  12. Design Strategy for a Pipelined ADC Employing Digital Post-correction

    NARCIS (Netherlands)

    Harpe, P.J.A.; Zanikopoulos, A.; Hegt, J.A.; Roermund, van A.H.M.

    2004-01-01

    This paper describes how the usage of digital post-correction techniques in pipelined analog-to-digital converters (ADC's) can be exploited optimally during the design-phase of the converter. It is known that post-correction algorithms reduce the influence of several cir- cuit impairments on the

  13. Algorithms for ADC multi-site test with digital input stimulus

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.; Zjajo, Amir; Gronthoud, Guido

    2009-01-01

    This paper reports two novel algorithms based on time-modulo reconstruction method intended for detection of the parametric faults in analogue-to-digital converters (ADC). In both algorithms, a pulse signal, in its slightly adapted form to allow sufficient time for converter settling, is taken as

  14. FASTBUS Readout Controller card for high speed data acquisition

    International Nuclear Information System (INIS)

    Zimmermann, S.

    1991-10-01

    This article describes a FASTBUS Readout Controller (FRC) for high speed data acquisition in FASTBUS based systems. The controller has two main interfaces: to FASTBUS and to a Readout Port. The FASTBUS interface performs FASTBUS master and slave operations at a maximum transfer rate exceeding 40 MBytes/s. The Readout Port can be adapted for a variety of protocols. Currently, it will be interfaced to a VME bus based processor with a VSB port. The on-board LR33000 embedded processor controls the readout, executing a list of operations download into its memory. It scans the FASTBUS modules and stores the data in a triple port DRAM (TPDRAM), through one of the Serial Access Memory (SAM) ports of the (TPDRAM). Later, it transfers this data to the readout port using the other SAM. The FRC also supports serial communication via RS232 and Ethernet interfaces. This device is intended for use in the data acquisition system at the Collider Detector at Fermilab. 5 refs., 3 figs

  15. Differentiation of benign and malignant lymph nodes with ADC value on diffusion MR: a Meta-analysis

    International Nuclear Information System (INIS)

    Long Miaomiao; Liu Lihua; Gao Guangfeng; Chen Lihua; Shen Wen; Qi Ji

    2012-01-01

    Objective: To summarize the diagnostic efficacy of ADC value for differentiation of benign and malignant lymph nodes on diffusion MRI with Meta-analysis. Methods: Published papers on differentiation of benign and malignant lymph nodes with ADC value were searched and reviewed. Quality evaluation was performed for the eligible papers before data extraction.Test for heterogeneity was performed first, then appropriate model was selected to calculate the weighted mean difference, sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio,pretest and posttest probability. The potential of ADC value for differentiation of benign and malignant lymph nodes was assessed qualitatively and quantitatively. Results: Fifteen papers including 735 cases and 1963 lymph nodes were selected. According to Meta-regression analysis, subgroup analysis and robust analysis, two studies with benign lymph nodes in patients with benign lesion and one study using chemical shift saturation technique were excluded because of their impact on the robustness of the pooled results. The weighted mean difference (WMD) between malignant and benign lymph nodes was -0.355 × 10 -3 mm 2 /s [95% confidence interval (CI):-0.423 ×10-3- -0.288 × 10 -3 mm 2 /s]. Although the cutoff of ADC value for differentiation in each study was different, the diagnostic efficacy was stable, the pooled sensitivity,specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under summarized receiver operator's curve were 0.87 (95% CI: 0.79-0.92), 0.87 (95% CI: 0.82-0.90), 6.5 (95% CI: 4.7-9.2), 0.15 (95% CI: 0.09-0.25), 43 (95% CI: 21-87), 0.93 (95% CI: 0.90-0.95). The posttest malignancy probability of benign lymph node indicated by ADC was 6%, while that of malignant lymph node was 72%. Conclusion: The ADC value can be used to differentiate benign and malignant lymph nodes with good sensitivity and specificity noninvasively. (authors)

  16. A 10-bit 80-MS/s opamp-sharing pipelined ADC with a switch-embedded dual-input MDAC

    Energy Technology Data Exchange (ETDEWEB)

    Yin Rui; Zhang Wei; Tang Zhangwen [ASIC and System State Key Laboratory, Fudan University, Shanghai 201203 (China); Liao Youchun, E-mail: zwtang@fudan.edu.cn [Ratio Microelectronics Co., Ltd, Shanghai 200433 (China)

    2011-02-15

    A 10-bit 80-MS/s opamp-sharing pipelined ADC is implemented in a 0.18-{mu}m CMOS. An opamp-sharing MDAC with a switch-embedded dual-input opamp is proposed to eliminate the non-resetting and successive-stage crosstalk problems observed in the conventional opamp-sharing technique. The ADC achieves a peak SNDR of 60.1 dB (ENOB = 9.69 bits) and a peak SFDR of 76 dB, while maintaining more than 9.6 ENOB for the full Nyquist input bandwidth. The core area of the ADC is 1.1 mm{sup 2} and the chip consumes 28 mW with a 1.8 V power supply. (semiconductor integrated circuits)

  17. Comparative study of the sensitivity of ADC value and T2 relaxation time for early detection of Wallerian degeneration

    International Nuclear Information System (INIS)

    Zhang Fan; Lu Guangming; Zee Chishing

    2011-01-01

    Background and purpose: Wallerian degeneration (WD), the secondary degeneration of axons from cortical and subcortical injuries, is associated with poor neurological outcome. There is some quantitative MR imaging techniques used to estimate the biologic changes secondary to delayed neuronal and axonal losses. Our purpose is to assess the sensitivity of ADC value and T 2 relaxation time for early detection of WD. Methods: Ten male Sprague-Dawley rats were used to establish in vivo Wallerian degeneration model of CNS by ipsilateral motor-sensory cortex ablation. 5 days after cortex ablation, multiecho-T 2 relaxometry and multi-b value DWI were acquired by using a 7 T MR imaging scanner. ADC-map and T 2 -map were reconstructed by post-processing. ROIs are selected according to pathway of corticospinal tract from cortex, internal capsule, cerebral peduncle, pons, medulla oblongata to upper cervical spinal cord to measure ADC value and T 2 relaxation time of healthy side and affected side. The results were compared between the side with cortical ablation and the side without ablation. Results: Excluding ablated cortex, ADC values of the corticospinal tract were significantly increased (P 2 relaxation time was observed between the affected and healthy sides. Imaging findings were correlated with histological examinations. Conclusion: As shown in this animal experiment, ADC values could non-invasively demonstrate the secondary degeneration involving descending white matter tracts. ADC values are more sensitive indicators for detection of early WD than T 2 relaxation time.

  18. Design and Implementation of Decimation Filter for 13-bit Sigma-Delta ADC Based on FPGA

    Directory of Open Access Journals (Sweden)

    Khalid Khaleel Mohammed

    2016-10-01

    Full Text Available A 13 bit Sigma-Delta ADC for a signal band of 40K Hz is designed in MATLAB Simulink and then implemented using Xilinx system generator tool.  The first order Sigma-Delta modulator is designed to work at a signal band of 40 KHz at an oversampling ratio (OSR of 256 with a sampling frequency of 20.48 MHz. The proposed decimation filter design is consists of a second order Cascaded Integrator Comb filter (CIC followed by two finite impulse response (FIR filters. This architecture reduces the need for multiplication which is need very large area. This architecture implements a decimation ratio of 256 and allows a maximum resolution of 13  bits in the output of the filter. The decimation filter was designed  and  tested  in  Xilinx  system  generator  tool  which  reduces  the  design  cycle  by  directly generating efficient VHDL code. The results obtained show that the overall Sigma-Delta ADC is able to achieve an ENOB (Effective Number Of Bit of 13.71 bits and SNR of 84.3 dB

  19. Exploring dynamics of embedded ADC through adapted digital input stimuli

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Kerkhoff, Hans G.; Zjajo, A.; Gronthoud, G.

    2008-01-01

    This paper reports an evaluation of adapted digital signals as a test stimulus to test dynamic parameters of analog-to-digital converters (ADC). In the first instance, the simplest digital waveform, a pulse signal, is taken as the test stimulus. The dynamics of the device under test while applying

  20. Diagnostic value of diffusion weighted MRI and ADC in differential ...

    African Journals Online (AJOL)

    Ankara Oncology Training and Research Hospital, Department of Radiology, Ankara/Turkey. 2. ... created and ADC values were measured for 72 liver masses and normal liver tissue (control group). ... ing MR gradient strength and duration) (b=400-1000 .... (B) Fat suppressed T1 weighted image after IV contrast showing.

  1. Rad-Hard Sigma-Delta 3-channel ADC for Fluxgate Magnetometers, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project aims to develop a multi-channel analog to digital converter (ADC) required for a fluxgate magnetometer (EPD) employed on NASA's planetary...

  2. Free-running ADC- and FPGA-based signal processing method for brain PET using GAPD arrays

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Wei [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Choi, Yong, E-mail: ychoi.image@gmail.com [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Hong, Key Jo [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Kang, Jihoon [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Jung, Jin Ho [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Huh, Youn Suk [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Lim, Hyun Keong; Kim, Sang Su [Department of Electronic Engineering, Sogang University, 1 Shinsu-Dong, Mapo-Gu, Seoul 121-742 (Korea, Republic of); Kim, Byung-Tae [Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Chung, Yonghyun [Department of Radiological Science, Yonsei University College of Health Science, 234 Meaji, Heungup Wonju, Kangwon-Do 220-710 (Korea, Republic of)

    2012-02-01

    Currently, for most photomultiplier tube (PMT)-based PET systems, constant fraction discriminators (CFD) and time to digital converters (TDC) have been employed to detect gamma ray signal arrival time, whereas anger logic circuits and peak detection analog-to-digital converters (ADCs) have been implemented to acquire position and energy information of detected events. As compared to PMT the Geiger-mode avalanche photodiodes (GAPDs) have a variety of advantages, such as compactness, low bias voltage requirement and MRI compatibility. Furthermore, the individual read-out method using a GAPD array coupled 1:1 with an array scintillator can provide better image uniformity than can be achieved using PMT and anger logic circuits. Recently, a brain PET using 72 GAPD arrays (4 Multiplication-Sign 4 array, pixel size: 3 mm Multiplication-Sign 3 mm) coupled 1:1 with LYSO scintillators (4 Multiplication-Sign 4 array, pixel size: 3 mm Multiplication-Sign 3 mm Multiplication-Sign 20 mm) has been developed for simultaneous PET/MRI imaging in our laboratory. Eighteen 64:1 position decoder circuits (PDCs) were used to reduce GAPD channel number and three off-the-shelf free-running ADC and field programmable gate array (FPGA) combined data acquisition (DAQ) cards were used for data acquisition and processing. In this study, a free-running ADC- and FPGA-based signal processing method was developed for the detection of gamma ray signal arrival time, energy and position information all together for each GAPD channel. For the method developed herein, three DAQ cards continuously acquired 18 channels of pre-amplified analog gamma ray signals and 108-bit digital addresses from 18 PDCs. In the FPGA, the digitized gamma ray pulses and digital addresses were processed to generate data packages containing pulse arrival time, baseline value, energy value and GAPD channel ID. Finally, these data packages were saved to a 128 Mbyte on-board synchronous dynamic random access memory (SDRAM) and

  3. Readout of the upgraded ALICE-ITS

    Science.gov (United States)

    Szczepankiewicz, A.; ALICE Collaboration

    2016-07-01

    The ALICE experiment will undergo a major upgrade during the second long shutdown of the CERN LHC. As part of this program, the present Inner Tracking System (ITS), which employs different layers of hybrid pixels, silicon drift and strip detectors, will be replaced by a completely new tracker composed of seven layers of monolithic active pixel sensors. The upgraded ITS will have more than twelve billion pixels in total, producing 300 Gbit/s of data when tracking 50 kHz Pb-Pb events. Two families of pixel chips realized with the TowerJazz CMOS imaging process have been developed as candidate sensors: the ALPIDE, which uses a proprietary readout and sparsification mechanism and the MISTRAL-O, based on a proven rolling shutter architecture. Both chips can operate in continuous mode, with the ALPIDE also supporting triggered operations. As the communication IP blocks are shared among the two chip families, it has been possible to develop a common Readout Electronics. All the sensor components (analog stages, state machines, buffers, FIFOs, etc.) have been modelled in a system level simulation, which has been extensively used to optimize both the sensor and the whole readout chain design in an iterative process. This contribution covers the progress of the R&D efforts and the overall expected performance of the ALICE-ITS readout system.

  4. Readout of the upgraded ALICE-ITS

    International Nuclear Information System (INIS)

    Szczepankiewicz, A.

    2016-01-01

    The ALICE experiment will undergo a major upgrade during the second long shutdown of the CERN LHC. As part of this program, the present Inner Tracking System (ITS), which employs different layers of hybrid pixels, silicon drift and strip detectors, will be replaced by a completely new tracker composed of seven layers of monolithic active pixel sensors. The upgraded ITS will have more than twelve billion pixels in total, producing 300 Gbit/s of data when tracking 50 kHz Pb–Pb events. Two families of pixel chips realized with the TowerJazz CMOS imaging process have been developed as candidate sensors: the ALPIDE, which uses a proprietary readout and sparsification mechanism and the MISTRAL-O, based on a proven rolling shutter architecture. Both chips can operate in continuous mode, with the ALPIDE also supporting triggered operations. As the communication IP blocks are shared among the two chip families, it has been possible to develop a common Readout Electronics. All the sensor components (analog stages, state machines, buffers, FIFOs, etc.) have been modelled in a system level simulation, which has been extensively used to optimize both the sensor and the whole readout chain design in an iterative process. This contribution covers the progress of the R&D efforts and the overall expected performance of the ALICE-ITS readout system.

  5. Readout of the upgraded ALICE-ITS

    Energy Technology Data Exchange (ETDEWEB)

    Szczepankiewicz, A., E-mail: Adam.Szczepankiewicz@cern.ch [CERN, Geneva (Switzerland); Institute of Computer Science, Warsaw University of Technology, Warsaw (Poland)

    2016-07-11

    The ALICE experiment will undergo a major upgrade during the second long shutdown of the CERN LHC. As part of this program, the present Inner Tracking System (ITS), which employs different layers of hybrid pixels, silicon drift and strip detectors, will be replaced by a completely new tracker composed of seven layers of monolithic active pixel sensors. The upgraded ITS will have more than twelve billion pixels in total, producing 300 Gbit/s of data when tracking 50 kHz Pb–Pb events. Two families of pixel chips realized with the TowerJazz CMOS imaging process have been developed as candidate sensors: the ALPIDE, which uses a proprietary readout and sparsification mechanism and the MISTRAL-O, based on a proven rolling shutter architecture. Both chips can operate in continuous mode, with the ALPIDE also supporting triggered operations. As the communication IP blocks are shared among the two chip families, it has been possible to develop a common Readout Electronics. All the sensor components (analog stages, state machines, buffers, FIFOs, etc.) have been modelled in a system level simulation, which has been extensively used to optimize both the sensor and the whole readout chain design in an iterative process. This contribution covers the progress of the R&D efforts and the overall expected performance of the ALICE-ITS readout system.

  6. Resistive Plate Chambers for hadron calorimetry: Tests with analog readout

    Energy Technology Data Exchange (ETDEWEB)

    Drake, Gary [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Repond, Jose [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States)]. E-mail: repond@hep.anl.gov; Underwood, David [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States); Xia, Lei [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL 60439 (United States)

    2007-07-21

    Resistive Plate Chambers (RPCs) are being developed for use in a hadron calorimeter with very fine segmentation of the readout. The design of the chambers and various tests with cosmic rays are described. This paper reports on the measurements with multi-bit (or analog) readout of either a single larger or multiple smaller readout pads.

  7. Timing and control requirements for a 32-channel AMU-ADC ASIC for the PHENIX detector

    International Nuclear Information System (INIS)

    Emery, M.S.; Ericson, M.N.; Britton, C.L. Jr.

    1998-01-01

    A custom CMOS Application Specific Integrated Circuit (ASIC) has been developed consisting of an analog memory unit (AMU) has been developed consisting of an analog memory unit (AMU) and analog to digital converter (ADC), both of which have been designed for applications in the PHENIX experiment. This IC consists of 32 pipes of analog memory with 64 cells per pipe. Each pipe also has its own ADC channel. Timing and control signal requirements for optimum performance are discussed in this paper

  8. FASTBUS readout system for the CDF DAQ upgrade

    International Nuclear Information System (INIS)

    Andresen, J.; Areti, H.; Black, D.

    1993-11-01

    The Data Acquisition System (DAQ) at the Collider Detector at Fermilab is currently being upgraded to handle a minimum of 100 events/sec for an aggregate bandwidth that is at least 25 Mbytes/sec. The DAQ System is based on a commercial switching network that has interfaces to VME bus. The modules that readout the front end crates (FASTBUS and RABBIT) have to deliver the data to the VME bus based host adapters of the switch. This paper describes a readout system that has the required bandwidth while keeping the experiment dead time due to the readout to a minimum

  9. The FE-I4 pixel readout integrated circuit

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Sciveres, M., E-mail: mgarcia-sciveres@bl.gov [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Arutinov, D.; Barbero, M. [University of Bonn, Bonn (Germany); Beccherle, R. [Istituto Nazionale di Fisica Nucleare Sezione di Genova, Genova (Italy); Dube, S.; Elledge, D. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Fleury, J. [Laboratoire de l' Accelerateur Lineaire, Orsay (France); Fougeron, D.; Gensolen, F. [Centre de Physique des Particules de Marseille, Marseille (France); Gnani, D. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Gromov, V. [Nationaal Instituut voor Subatomaire Fysica, Amsterdam (Netherlands); Hemperek, T.; Karagounis, M. [University of Bonn, Bonn (Germany); Kluit, R. [Nationaal Instituut voor Subatomaire Fysica, Amsterdam (Netherlands); Kruth, A. [University of Bonn, Bonn (Germany); Mekkaoui, A. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Menouni, M. [Centre de Physique des Particules de Marseille, Marseille (France); Schipper, J.-D. [Nationaal Instituut voor Subatomaire Fysica, Amsterdam (Netherlands)

    2011-04-21

    A new pixel readout integrated circuit denominated FE-I4 is being designed to meet the requirements of ATLAS experiment upgrades. It will be the largest readout IC produced to date for particle physics applications, filling the maximum allowed reticle area. This will significantly reduce the cost of future hybrid pixel detectors. In addition, FE-I4 will have smaller pixels and higher rate capability than the present generation of LHC pixel detectors. Design features are described along with simulation and test results, including low power and high rate readout architecture, mixed signal design strategy, and yield hardening.

  10. FAIR: A new fast trigger and readout bus system

    International Nuclear Information System (INIS)

    Ordine, A.; Boiano, A.; Zaghi, A.

    1998-01-01

    FAIR (FAst Intercrate Readout) is a synchronous ECL bus system dedicated to readout. It is based on a new trigger and readout hardware level protocol and on a new control system that learns how to setup and control modules. The hardware protocol along with the data structure allow both readout and event building at the same time at the rate of 22 ns/longword (1.44 Gbit/s) without the need of CPUs. It performs trigger management and full pipelining by using a multilevel FIFO structure. FAIR provides for a multi-crate front-end environment and uses an embedded serial network to accomplish front-end control and setup. The data transfer measured performances and the control system are presented in some detail

  11. A reconfigurable image tube using an external electronic image readout

    Science.gov (United States)

    Lapington, J. S.; Howorth, J. R.; Milnes, J. S.

    2005-08-01

    We have designed and built a sealed tube microchannel plate (MCP) intensifier for optical/NUV photon counting applications suitable for 18, 25 and 40 mm diameter formats. The intensifier uses an electronic image readout to provide direct conversion of event position into electronic signals, without the drawbacks associated with phosphor screens and subsequent optical detection. The Image Charge technique is used to remove the readout from the intensifier vacuum enclosure, obviating the requirement for additional electrical vacuum feedthroughs and for the readout pattern to be UHV compatible. The charge signal from an MCP intensifier is capacitively coupled via a thin dielectric vacuum window to the electronic image readout, which is external to the sealed intensifier tube. The readout pattern is a separate item held in proximity to the dielectric window and can be easily detached, making the system easily reconfigurable. Since the readout pattern detects induced charge and is external to the tube, it can be constructed as a multilayer, eliminating the requirement for narrow insulator gaps and allowing it to be constructed using standard PCB manufacturing tolerances. We describe two readout patterns, the tetra wedge anode (TWA), an optimized 4 electrode device similar to the wedge and strip anode (WSA) but with a factor 2 improvement in resolution, and an 8 channel high speed 50 ohm device, both manufactured as multilayer PCBs. We present results of the detector imaging performance, image resolution, linearity and stability, and discuss the development of an integrated readout and electronics device based on these designs.

  12. Imaging achievements with the Vernier readout

    CERN Document Server

    Lapington, J S; Worth, L B C; Tandy, J A

    2002-01-01

    We describe the Vernier anode, a high resolution and charge division image readout for microchannel plate detectors. It comprises a planar structure of insulated electrodes deposited on an insulating substrate. The charge cloud from an event is divided amongst all nine electrodes and the charge ratio uniquely determines the two-dimensional position coordinate of the charge centroid. We discuss the design of the anode pattern and describe the advantages offered by this readout. The cyclic variation of the electrode structure allows the image resolution to exceed the charge measurement resolution and enables the entire active area of the readout to be utilized. In addition, fixed pattern noise is greatly reduced. We present results demonstrating the position resolution and image linearity. A position resolution of 10 mu m FWHM is demonstrated and the overall imaging performance is shown to be limited by the microchannel plate pore spacing. We present measurements of the image distortions and describe techniques...

  13. The NA60 experiment readout architecture

    CERN Document Server

    Floris, M; Usai, G L; David, A; Rosinsky, P; Ohnishi, H

    2004-01-01

    The NA60 experiment was designed to identify signatures of a new state of matter, the Quark Gluon Plasma, in heavy-ion collisions at the CERN Super Proton Synchroton. The apparatus is composed of four main detectors: a muon spectrometer (MS), a zero degree calorimeter (ZDC), a silicon vertex telescope (VT), and a silicon microstrip beam tracker (BT). The readout of the whole experiment is based on a PCI architecture. The basic unit is a general purpose PCI card, interfaced to the different subdetectors via custom mezzanine cards. This allowed us to successfully implement several completely different readout protocols (from the VME like protocol of the MS to the custom protocol of the pixel telescope). The system was fully tested with proton and ion beams, and several million events were collected in 2002 and 2003. This paper presents the readout architecture of NA60, with particular emphasis on the PCI layer common to all the subdetectors. (16 refs).

  14. A 100 MS/s 9 bit 0.43 mW SAR ADC with custom capacitor array

    Science.gov (United States)

    Jingjing, Wang; Zemin, Feng; Rongjin, Xu; Chixiao, Chen; Fan, Ye; Jun, Xu; Junyan, Ren

    2016-05-01

    A low power 9 bit 100 MS/s successive approximation register analog-to-digital converter (SAR ADC) with custom capacitor array is presented. A brand-new 3-D MOM unit capacitor is used as the basic capacitor cell of this capacitor array. The unit capacitor has a capacitance of 1 fF. Besides, the advanced capacitor array structure and switch mode decrease the power consumption a lot. To verify the effectiveness of this low power design, the 9 bit 100 MS/s SAR ADC is implemented in TSMC IP9M 65 nm LP CMOS technology. The measurement results demonstrate that this design achieves an effective number of bits (ENOB) of 7.4 bit, a signal-to-noise plus distortion ratio (SNDR) of 46.40 dB and a spurious-free dynamic range (SFDR) of 62.31 dB at 100 MS/s with 1 MHz input. The SAR ADC core occupies an area of 0.030 mm2 and consumes 0.43 mW under a supply voltage of 1.2 V. The figure of merit (FOM) of the SAR ADC achieves 23.75 fJ/conv. Project supported by the National High-Tech Research and Development Program of China (No. 2013AA014101).

  15. LHCb: A new Readout Control system for the LHCb Upgrade

    CERN Multimedia

    Alessio, F

    2012-01-01

    The LHCb experiment has proposed an upgrade towards a full 40 MHz readout system in order to run between five and ten times its initial design luminosity. The entire readout architecture will be upgraded in order to cope with higher sub-detector occupancies, higher rate and higher network load. In this paper, we describe the architecture, functionalities and the first hardware implementation of a new Readout Control system for the LHCb upgrade. The system is based on FPGAs and bi-directional links for the control of the entire readout architecture. First results on the validation of the system are also given.

  16. Multi-Anode Photomultplier (MAPMT) readout for High Granularity Calorimeters

    CERN Document Server

    Mkrtchyan, Tigran; The ATLAS collaboration

    2017-01-01

    Hadron calorimeter high performance in jet sub-structure measurements can be achieved for objects with $p_{T}$ greater than 1 TeV if the readout geometry is finely segmented in $\\Delta\\eta \\times \\Delta\\phi$. A feasibility study to increase the readout granularity of TileCal, the central hadron calorimeter of the ATLAS detector, is presented. We show a preliminary study exploring the possibility to increase by a factor 4 the present readout granularity of the inner layer cells of TileCal (0.1->0.025 in $\\Delta\\eta$) and to split into two layers the intermediate section of TileCal. The proposed solution is designed to cope with mechanical and readout bandwidth and power constraints. Assuming that the mechanics of the Tile modules cannot be changed, Multi-Anode PMTs with same boundary geometry of the present single-anode PMTs are considered to readout WLS bers, ideally one per pixel, carrying the signals from the individual scintillating tiles of each detector cells. The discussed challenges of the design are: ...

  17. A readout buffer prototype for ATLAS high-level triggers

    CERN Document Server

    Calvet, D; Huet, M; Le Dû, P; Mandjavidze, I D; Mur, M

    2001-01-01

    Readout buffers are critical components in the dataflow chain of the ATLAS trigger/data-acquisition system. At up to 75 kHz, after each Level-1 trigger accept signal, these devices receive and store digitized data from groups of front-end electronic channels. Several readout buffers are grouped to form a readout buffer complex that acts as a data server for the high-level trigger selection algorithms and for the final data-collection system. This paper describes a functional prototype of a readout buffer based on a custom-made PCI mezzanine card that is designed to accept input data at up to 160 MB /s, to store up to 8 MB of data, and to distribute data chunks at the desired request rate. We describe the hardware of the card that is based on an Intel 1960 processor and complex programmable logic devices. We present the integration of several of these cards in a readout buffer complex. We measure various performance figures and discuss to which extent these can fulfil ATLAS needs. (5 refs).

  18. A Design of a New Column-Parallel Analog-to-Digital Converter Flash for Monolithic Active Pixel Sensor

    Directory of Open Access Journals (Sweden)

    Mostafa Chakir

    2017-01-01

    Full Text Available The CMOS Monolithic Active Pixel Sensor (MAPS for the International Linear Collider (ILC vertex detector (VXD expresses stringent requirements on their analog readout electronics, specifically on the analog-to-digital converter (ADC. This paper concerns designing and optimizing a new architecture of a low power, high speed, and small-area 4-bit column-parallel ADC Flash. Later in this study, we propose to interpose an S/H block in the converter. This integration of S/H block increases the sensitiveness of the converter to the very small amplitude of the input signal from the sensor and provides a sufficient time to the converter to be able to code the input signal. This ADC is developed in 0.18 μm CMOS process with a pixel pitch of 35 μm. The proposed ADC responds to the constraints of power dissipation, size, and speed for the MAPS composed of a matrix of 64 rows and 48 columns where each column ADC covers a small area of 35 × 336.76 μm2. The proposed ADC consumes low power at a 1.8 V supply and 100 MS/s sampling rate with dynamic range of 125 mV. Its DNL and INL are 0.0812/−0.0787 LSB and 0.0811/−0.0787 LSB, respectively. Furthermore, this ADC achieves a high speed more than 5 GHz.

  19. A Design of a New Column-Parallel Analog-to-Digital Converter Flash for Monolithic Active Pixel Sensor.

    Science.gov (United States)

    Chakir, Mostafa; Akhamal, Hicham; Qjidaa, Hassan

    2017-01-01

    The CMOS Monolithic Active Pixel Sensor (MAPS) for the International Linear Collider (ILC) vertex detector (VXD) expresses stringent requirements on their analog readout electronics, specifically on the analog-to-digital converter (ADC). This paper concerns designing and optimizing a new architecture of a low power, high speed, and small-area 4-bit column-parallel ADC Flash. Later in this study, we propose to interpose an S/H block in the converter. This integration of S/H block increases the sensitiveness of the converter to the very small amplitude of the input signal from the sensor and provides a sufficient time to the converter to be able to code the input signal. This ADC is developed in 0.18  μ m CMOS process with a pixel pitch of 35  μ m. The proposed ADC responds to the constraints of power dissipation, size, and speed for the MAPS composed of a matrix of 64 rows and 48 columns where each column ADC covers a small area of 35 × 336.76  μ m 2 . The proposed ADC consumes low power at a 1.8 V supply and 100 MS/s sampling rate with dynamic range of 125 mV. Its DNL and INL are 0.0812/-0.0787 LSB and 0.0811/-0.0787 LSB, respectively. Furthermore, this ADC achieves a high speed more than 5 GHz.

  20. Study for the LHCb upgrade read-out board

    CERN Document Server

    Cachemiche, J P; Hachon, F; Le Gac, R; Marin, F; 10.1088/1748-0221/5/12/C12036

    2010-01-01

    The LHCb experiment envisages to upgrade its readout electronics in order to increase the readout rate from 1 MHz to 40 MHz. This electronics upgrade is very challenging, since readout boards will have to handle a higher number of serial links with an increased bandwidth. In addition, the new communication protocol (GBT) developed by the CERN micro-electronics group mixes data acquisition, slow control and clock distribution on the same link. To explore the feasibility of such a readout system, elementary building blocks have been studied. Their goals are multiple: understand signal integrity when using highly integrated high speed serial links running at 8 - 10 Gbits/s; test the implementation of the GBT protocol within FPGAs; understand advantages and limitations of commercial standard with a predefined interconnection topology; validate ideas on how to control easily such a system. We designed two boards compliant with the xTCA standard which meets an increasing interest in the physics community. The first...

  1. A 0.7V 7-to-10bit 0-to-2MS/s Flexible SAR ADC for Ultra Low-Power Wireless Sensor Nodes

    NARCIS (Netherlands)

    Harpe, P.J.A.; Dolmans, G.; Philips, K.J.P.; Groot, de H.W.H.

    2012-01-01

    This paper presents a flexible SAR ADC in 90nm CMOS for wireless sensor nodes. By supporting resolutions from 7 to 10bit and sample rates from DC to 2MS/s, this design can be used for a variety of applications such as sensor interfacing and receiver frontends. Flexibility is achieved by a

  2. A high speed low power low offset dynamic comparator used in SHA-less pipelined ADC

    Science.gov (United States)

    Shubin, Liu; Zhangming, Zhu; Yintang, Yang; Lianxi, Liu

    2014-05-01

    A novel fully differential high speed high resolution low offset CMOS dynamic comparator has been implemented in the SMIC 0.18 μm process used for a sample-and-hold amplifier (SHA)-less pipelined analog-to-digital converters (ADC). Based on the analysis and optimization between delay time and offset, an enhanced reset architecture with transmission gate was introduced to speed up the comparison and reset procedure. Four inputs with two cross coupled differential pairs, reconstituted bias circuit for tail current transistor and common centroid layouts make the comparator more robust against mismatch and process variations. The simulation results demonstrate that the proposed design achieves 1 mV sensitivity at 2.2 GHz sampling rate with a power consumption of 510 μW, while the mean offset voltage is equal to 10.244 mV.

  3. Study on two-dimensional induced signal readout of MRPC

    International Nuclear Information System (INIS)

    Wu Yucheng; Yue Qian; Li Yuanjing; Ye Jin; Cheng Jianping; Wang Yi; Li Jin

    2012-01-01

    A kind of two-dimensional readout electrode structure for the induced signal readout of MRPC has been studied in both simulation and experiments. Several MRPC prototypes are produced and a series of test experiments have been done to compare with the result of simulation, in order to verify the simulation model. The experiment results are in good agreement with those of simulation. This method will be used to design the two-dimensional signal readout mode of MRPC in the future work.

  4. High-speed, multi-channel detector readout electronics for fast radiation detectors

    International Nuclear Information System (INIS)

    Hennig, Wolfgang

    2012-01-01

    In this project, we are developing a high speed digital spectrometer that a) captures detector waveforms at rates up to 500 MSPS b) has upgraded event data acquisition with additional data buffers for zero dead time operation c) moves energy calculations to the FPGA to increase spectrometer throughput in fast scintillator applications d) uses a streamlined architecture and high speed data interface for even faster readout to the host PC These features are in addition to the standard functions in our existing spectrometers such as digitization, programmable trigger and energy filters, pileup inspection, data acquisition with energy and time stamps, MCA histograms, and run statistics. In Phase I, we upgraded one of our existing spectrometer designs to demonstrate the key principle of fast waveform capture using a 500 MSPS, 12 bit ADC and a Xilinx Virtex-4 FPGA. This upgraded spectrometer, named P500, performed well in initial tests of energy resolution, pulse shape analysis, and timing measurements, thus achieving item (a) above. In Phase II, we are revising the P500 to build a commercial prototype with the improvements listed in items (b)-(d). As described in the previous report, two devices were built to pursue this goal, named the Pixie-500 and the Pixie-500 Express. The Pixie-500 has only minor improvements from the Phase I prototype and is intended as an early commercial product (its production and part of its development were funded outside the SBIR). It also allows testing of the ADC performance in real applications. The Pixie-500 Express (or Pixie-500e) includes all of the improvements (b)-(d). At the end of Phase II of the project, we have tested and debugged the hardware, firmware and software of the Pixie-500 Express prototype boards delivered 12/3/2010. This proved substantially more complex than anticipated. At the time of writing, all hardware bugs have been fixed, the PCI Express interface is working, the SDRAM has been successfully tested and the

  5. High-speed, multi-channel detector readout electronics for fast radiation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hennig, Wolfgang

    2012-06-22

    In this project, we are developing a high speed digital spectrometer that a) captures detector waveforms at rates up to 500 MSPS b) has upgraded event data acquisition with additional data buffers for zero dead time operation c) moves energy calculations to the FPGA to increase spectrometer throughput in fast scintillator applications d) uses a streamlined architecture and high speed data interface for even faster readout to the host PC These features are in addition to the standard functions in our existing spectrometers such as digitization, programmable trigger and energy filters, pileup inspection, data acquisition with energy and time stamps, MCA histograms, and run statistics. In Phase I, we upgraded one of our existing spectrometer designs to demonstrate the key principle of fast waveform capture using a 500 MSPS, 12 bit ADC and a Xilinx Virtex-4 FPGA. This upgraded spectrometer, named P500, performed well in initial tests of energy resolution, pulse shape analysis, and timing measurements, thus achieving item (a) above. In Phase II, we are revising the P500 to build a commercial prototype with the improvements listed in items (b)-(d). As described in the previous report, two devices were built to pursue this goal, named the Pixie-500 and the Pixie-500 Express. The Pixie-500 has only minor improvements from the Phase I prototype and is intended as an early commercial product (its production and part of its development were funded outside the SBIR). It also allows testing of the ADC performance in real applications.The Pixie-500 Express (or Pixie-500e) includes all of the improvements (b)-(d). At the end of Phase II of the project, we have tested and debugged the hardware, firmware and software of the Pixie-500 Express prototype boards delivered 12/3/2010. This proved substantially more complex than anticipated. At the time of writing, all hardware bugs have been fixed, the PCI Express interface is working, the SDRAM has been successfully tested and the SHARC

  6. First performance results of the ALICE TPC Readout Control Unit 2

    OpenAIRE

    Zhao, Chengxin; Alme, Johan; Alt, Torsten; Appelshäuser, Harald; Bratrud, Lars Karlot Stubberud; Castro, Andrew; Costa, Filippo; David, Ernö; Gunji, Tako; Kirsch, S; Kiss, Tivadar; Langøy, Rune; Lien, Jørgen; Lippmann, C; Oskarsson, Anders

    2016-01-01

    - This paper presents the first performance results of the ALICE TPC Readout Control Unit 2 (RCU2). With the upgraded hardware typology and the new readout scheme in FPGA design, the RCU2 is designed to achieve twice the readout speed of the present Readout Control Unit. Design choices such as using the flash-based Microsemi Smartfusion2 FPGA and applying mitigation techniques in interfaces and FPGA design ensure a high degree of radiation tolerance. This paper presents the system level ir...

  7. A new method for reducing DNL in nuclear ADCs using an interpolation technique

    International Nuclear Information System (INIS)

    Vaidya, P.P.; Gopalakrishnan, K.R.; Pethe, V.A.; Anjaneyulu, T.

    1986-01-01

    The paper describes a new method for reducing the DNL associated with nuclear ADCs. The method named the ''interpolation technique'' is utilized to derive the quantisation steps corresponding to the last n bits of the digital code by dividing quantisation steps due to higher significant bits of the DAC, using a chain of resistors. Using comparators, these quantisation steps are compared with the analog voltage to be digitized, which is applied as a voltage shift at both ends of this chain. The output states of the comparators define the n bit code. The errors due to offset voltages and bias currents of the comparators are statistically neutralized by changing the polarity of quantisation steps as well as the polarity of analog voltage (corresponding to last n bits) for alternate A/D conversion. The effect of averaging on the channel profile can be minimized. A 12 bit ADC was constructured using this technique which gives DNL of less than +-1% over most of the channels for conversion time of nearly 4.5 μs. Gatti's sliding scale technique can be implemented for further reduction of DNL. The interpolation technique has a promising potential of improving the resolution of existing 12 bit ADCs to 16 bit, without degrading the percentage DNL significantly. (orig.)

  8. Dynamic changes in water ADC, energy metabolism, extracellular space volume and tortuosity in neonatal rat brain during irreversible ischemia

    NARCIS (Netherlands)

    Toorn, van der A.; Syková, E.; Dijkhuizen, R.M.; Voríšek, I.; Vargová, L.; Skobisová, E.; Lookeren Campagne, van M.; Reese, T.; Nicolaij, K.

    1996-01-01

    To obtain a better understanding of the mechanisms underlying early changes in the brain water apparent diffusion coefficient (ADC) observed in cerebral ischemia, dynamic changes in the ADC of water and in the energy status were measured at postnatal day 8 or 9 in neonatal rat brains after cardiac

  9. Development of a Multichannel Analyzer for modular ADCs

    International Nuclear Information System (INIS)

    Bannos Rodriguez, U.; Diaz Castro, M.; Rivero Ramirez, D.

    2013-01-01

    This paper describes the design and construction of a multichannel analyzer with USB interface from ADC module of the Fast ComTec 7074. One PIC18F4550 microprocessor from Microchip, one CPLD isPLSI 1032E from Lattice and one 32Kx8 SRAM memory were used. It also includes details of the programming circuitry and development of program acquisition, storage and display of the spectra using the Qt libraries. Finally, preliminary tests to the device are show. (Author)

  10. Latest generation of ASICs for photodetector readout

    Science.gov (United States)

    Seguin-Moreau, N.

    2013-08-01

    The OMEGA microelectronics group has designed a new generation of multichannel integrated circuits, the "ROC" family, in AustrianMicroSystem (AMS) SiGe 0.35 μm technology to read out signals from various families of photodetectors. The chip named MAROC (standing for Multi Anode ReadOut Chip) has been designed to read out MultiAnode Photomultipliers (MAPMT), Photomultiplier ARray In SiGe ReadOut Chip (PARISROC) to read out Photomultipliers (PMTs) and SiPM Integrated ReadOut Chip (SPIROC) to readout Silicon PhotoMultiplier (SiPM) detectors and which was the first ASIC to do so. The three of them fulfill the stringent requirements of the future photodetectors, in particular in terms of low noise, radiation hardness, large dynamic range, high density and high speed while keeping low power thanks to the SiGe technology. These multi-channel ASICs are real System on Chip (SoC) as they provide charge, time and photon-counting information which are digitized internally. Their complexity and versatility enable innovative frontier detectors and also cover spin off of these detectors in adjacent fields such as medical or material imaging as well as smart detectors. In this presentation, the three ASIC architectures and test results will be described to give a general panorama of the "ROC" chips.

  11. Latest generation of ASICs for photodetector readout

    Energy Technology Data Exchange (ETDEWEB)

    Seguin-Moreau, N., E-mail: seguin@lal.in2p3.fr [Laboratoire de l’Accélérateur Linéaire, IN2P3-CNRS, Université Paris-Sud, Bâtiment 200, 91898 Orsay Cedex (France)

    2013-08-01

    The OMEGA microelectronics group has designed a new generation of multichannel integrated circuits, the “ROC” family, in AustrianMicroSystem (AMS) SiGe 0.35 μm technology to read out signals from various families of photodetectors. The chip named MAROC (standing for Multi Anode ReadOut Chip) has been designed to read out MultiAnode Photomultipliers (MAPMT), Photomultiplier ARray In SiGe ReadOut Chip (PARISROC) to read out Photomultipliers (PMTs) and SiPM Integrated ReadOut Chip (SPIROC) to readout Silicon PhotoMultiplier (SiPM) detectors and which was the first ASIC to do so. The three of them fulfill the stringent requirements of the future photodetectors, in particular in terms of low noise, radiation hardness, large dynamic range, high density and high speed while keeping low power thanks to the SiGe technology. These multi-channel ASICs are real System on Chip (SoC) as they provide charge, time and photon-counting information which are digitized internally. Their complexity and versatility enable innovative frontier detectors and also cover spin off of these detectors in adjacent fields such as medical or material imaging as well as smart detectors. In this presentation, the three ASIC architectures and test results will be described to give a general panorama of the “ROC” chips.

  12. Latest generation of ASICs for photodetector readout

    International Nuclear Information System (INIS)

    Seguin-Moreau, N.

    2013-01-01

    The OMEGA microelectronics group has designed a new generation of multichannel integrated circuits, the “ROC” family, in AustrianMicroSystem (AMS) SiGe 0.35 μm technology to read out signals from various families of photodetectors. The chip named MAROC (standing for Multi Anode ReadOut Chip) has been designed to read out MultiAnode Photomultipliers (MAPMT), Photomultiplier ARray In SiGe ReadOut Chip (PARISROC) to read out Photomultipliers (PMTs) and SiPM Integrated ReadOut Chip (SPIROC) to readout Silicon PhotoMultiplier (SiPM) detectors and which was the first ASIC to do so. The three of them fulfill the stringent requirements of the future photodetectors, in particular in terms of low noise, radiation hardness, large dynamic range, high density and high speed while keeping low power thanks to the SiGe technology. These multi-channel ASICs are real System on Chip (SoC) as they provide charge, time and photon-counting information which are digitized internally. Their complexity and versatility enable innovative frontier detectors and also cover spin off of these detectors in adjacent fields such as medical or material imaging as well as smart detectors. In this presentation, the three ASIC architectures and test results will be described to give a general panorama of the “ROC” chips

  13. FIPSER: Performance study of a readout concept with few digitization levels for fast signals

    Energy Technology Data Exchange (ETDEWEB)

    Limyansky, B., E-mail: brent.limyansky@gatech.edu [School of Physics and Center for Relativistic Astrophysics, Georgia Institute of Technology, Atlanta (United States); Reese, R., E-mail: bobbeyreese@gmail.com [School of Physics and Center for Relativistic Astrophysics, Georgia Institute of Technology, Atlanta (United States); Cressler, J.D. [School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta (United States); Otte, A.N.; Taboada, I. [School of Physics and Center for Relativistic Astrophysics, Georgia Institute of Technology, Atlanta (United States); Ulusoy, C. [Dept. of Electrical and Computer Engineering, Michigan State University, East Lansing (United States)

    2016-11-21

    We discuss the performance of a readout system, Fixed Pulse Shape Efficient Readout (FIPSER), to digitize signals from detectors with a fixed pulse shape. In this study we are mainly interested in the readout of fast photon detectors like photomultipliers or Silicon photomultipliers. But the concept can be equally applied to the digitization of other detector signals. FIPSER is based on the flash analog to digital converter (FADC) concept, but has the potential to lower costs and power consumption by using an order of magnitude fewer discrete voltage levels. Performance is bolstered by combining the discretized signal with the knowledge of the underlying pulse shape. Simulated FIPSER data was reconstructed with two independent methods. One using a maximum likelihood method and the other using a modified χ{sup 2} test. Both methods show that utilizing 12 discrete voltage levels with a sampling rate of 4 samples per full width half maximum (FWHM) of the pulse achieves an amplitude resolution that is better than the Poisson limit for photon-counting experiments. The time resolution achieved in this configuration ranges between 0.02 and 0.16 FWHM and depends on the pulse amplitude. In a situation where the waveform is composed of two consecutive pulses the pulses can be separated if they are at least 0.05–0.30 FWHM apart with an amplitude resolution that is better than 20%.

  14. A radiation-tolerant electronic readout system for portal imaging

    Science.gov (United States)

    Östling, J.; Brahme, A.; Danielsson, M.; Iacobaeus, C.; Peskov, V.

    2004-06-01

    A new electronic portal imaging device, EPID, is under development at the Karolinska Institutet and the Royal Institute of Technology. Due to considerable demands on radiation tolerance in the radiotherapy environment, a dedicated electronic readout system has been designed. The most interesting aspect of the readout system is that it allows to read out ˜1000 pixels in parallel, with all electronics placed outside the radiation beam—making the detector more radiation resistant. In this work we are presenting the function of a small prototype (6×100 pixels) of the electronic readout board that has been tested. Tests were made with continuous X-rays (10-60 keV) and with α particles. The results show that, without using an optimised gas mixture and with an early prototype only, the electronic readout system still works very well.

  15. Readout ASIC of pair-monitor for international linear collider

    International Nuclear Information System (INIS)

    Sato, Yutaro; Ikeda, Hirokazu; Ito, Kazutoshi; Miyamoto, Akiya; Nagamine, Tadashi; Sasaki, Rei; Takubo, Yosuke; Tauchi, Toshiaki; Yamamoto, Hitoshi

    2010-01-01

    The pair-monitor is a beam profile monitor at the interaction point of the international linear collider. A prototype of the readout ASIC for the pair-monitor has been designed and tested. Since the pair-monitor uses the hit distribution of electrons and positrons generated by the beam-crossing to measure the beam profile, the readout ASIC is designed to count the number of hits. In a prototype ASIC, 36 readout cells were implemented by TSMC 0.25-μm CMOS process. Each readout cell is equipped with an amplifier, comparator, 8-bit counter and 16 count-registers. By the operation test, all the ASIC component were confirmed to work correctly. As the next step, we develop the prototype ASIC with the silicon on insulator technology. It is produced with OKI 0.2-μm FD-SOI CMOS process.

  16. Electronics Development for the ATLAS Liquid Argon Calorimeter Trigger and Readout for Future LHC Running

    CERN Document Server

    Pacheco Rodriguez, Laura; The ATLAS collaboration

    2016-01-01

    The upgrade of the LHC will provide up to 7.5 times greater instantaneous and total luminosities than assumed in the original design of the ATLAS Liquid Argon (LAr) Calorimeters. The radiation tolerance criteria and the improved trigger system with higher acceptance rate and longer latency require an upgrade of the LAr readout electronics. In the first upgrade phase in 2019-2020, a trigger-readout with up to 10 times higher granularity will be implemented. This allows an improved reconstruction of electromagnetic and hadronic showers and will reduce the background for electron, photon and energy-flow signals at the first trigger level. The analog and digital signal processing components are currently in their final design stages and a fully functional demonstrator system is operated and tested on the LAr Calorimeters. In a second upgrade stage in 2024-2026, the readout of all 183,000 LAr Calorimeter cells will be performed without trigger selection at 40 MHz sampling rate and 16 bit dynamic range. Calibrated ...

  17. 100 Gbps PCI-Express Readout for the LHCb Upgrade

    CERN Document Server

    Durante, Paolo; Schwemmer, Rainer; Marconi, Umberto; Balbi, Gabriele; Lax, Ignazio

    2015-01-01

    We present a new data acquisition system under development for the next upgrade of the LHCb experiment at CERN. We focus in particular on the design of a new common readout board, the PCIe40, and on the viability of PCI-Express as an interconnect technology for high speed readout. We describe a new high-performance DMA controller for data acquisition, implemented on an FPGA, coupled with a custom software module for the Linux kernel. Lastly, we describe how these components can be leveraged to achieve a throughput of 100 Gbit/s per readout board.

  18. Microprocessor controlled dual parameter ADC system with a CAMAC interface

    Energy Technology Data Exchange (ETDEWEB)

    Perry, D G; Nickell, Jr, J D [Los Alamos Scientific Lab., NM (USA)

    1978-09-01

    Presented here is the design of a dual parameter ADC system which is controlled by a microprocessor and also interfaced to CAMAC. The system was designed to be mobile in that it may work wherever there is a CAMAC crate. In such cases where the CAMAC system is inoperative, the system may operate in a stand-alone mode.

  19. Comparison between two possible CMS Barrel Muon Readout Architectures

    International Nuclear Information System (INIS)

    Aguayo, P.; Barcala, J.M.; Molinero, A.; Pablos, J.L.; Willmott, C.; Alberdi, J.; Marin, J.; Navarrete, J.; Romero, L.

    1997-01-01

    A comparison between two possible readout arquitectures for the CMS muon barrel readout electronics is presented, including various aspects like costs, reliability, installation, staging and maintenance. A review of the present baseline architecture is given in the appendix. (Author)

  20. The Readout Control Unit of the ALICE TPC

    CERN Document Server

    Lien, J A; Musa, L

    2004-01-01

    The ALICE Time Projection Chamber (TPC) is the main tracking detector of the central barrel of the ALICE (A Large Ion Collider) Experiment at the Large Hadron Collider (LHC), being constructed at CERN, Geneva. It is a 88 m$^{3}$ cylinder filled with gas and divided into two drift regions by the central electrode located at its axial center. The readout chambers of the TPC are multi-wire proportional chambers with cathode pad readout. About 570 000 pads are read-out by an electronics chain of amplification, digitalization and pre-processing. One of the challenges in designing the TPC for ALICE is the design of Front End Electronics (FEE) to cope with the data rates and the channel occupancy. The Readout Control Unit (RCU), which is presented in this work, is designed to control and monitor the Front End Electronics, and to collect and ship data to the High Level Trigger and the Data Acquisition System, via the Detector Data Link (DDL - optical fibre). The RCU must be capable of reading out up to 200 Mbytes/s f...

  1. Comparing interferometry techniques for multi-degree of freedom test mass readout

    International Nuclear Information System (INIS)

    Isleif, Katharina-Sophie; Gerberding, Oliver; Mehmet, Moritz; Schwarze, Thomas S; Heinzel, Gerhard; Danzmann, Karsten

    2016-01-01

    Laser interferometric readout systems with 1pm/Hz precision over long time scales have successfully been developed for LISA and LISA Pathfinder. Future gravitational physics experiments, for example in the fields of gravitational wave detection and geodesy, will potentially require similar levels of displacement and tilt readouts of multiple test masses in multiple degrees of freedom. In this article we compare currently available classic interferometry schemes with new techniques using phase modulations and complex readout algorithms. Based on a simple example we show that the new techniques have great potential to simplify interferometric readouts. (paper)

  2. Strip detectors read-out system user's guide

    International Nuclear Information System (INIS)

    Claus, G.; Dulinski, W.; Lounis, A.

    1996-01-01

    The Strip Detector Read-out System consists of two VME modules: SDR-Flash and SDR-seq completed by a fast logic SDR-Trig stand alone card. The system is a self-consistent, cost effective and easy use solution for the read-out of analog multiplexed signals coming from some of the front-end electronics chips (Viking/VA chips family, Premus 128 etc...) currently used together with solid (silicon) or gas microstrip detectors. (author)

  3. Comparative study of the sensitivity of ADC value and T{sub 2} relaxation time for early detection of Wallerian degeneration

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Fan [Department of Radiology, Nanjing Jinling Hospital, Clinical School of Medical College of Nanjing University, Nanjing 210002 (China); Lu Guangming, E-mail: cjr.luguangming@vip.163.com [Department of Radiology, Nanjing Jinling Hospital, Clinical School of Medical College of Nanjing University, Nanjing 210002 (China); Zee Chishing, E-mail: chishing@usc.edu [Department of Radiology, USC Keck School of Medicine (United States)

    2011-07-15

    Background and purpose: Wallerian degeneration (WD), the secondary degeneration of axons from cortical and subcortical injuries, is associated with poor neurological outcome. There is some quantitative MR imaging techniques used to estimate the biologic changes secondary to delayed neuronal and axonal losses. Our purpose is to assess the sensitivity of ADC value and T{sub 2} relaxation time for early detection of WD. Methods: Ten male Sprague-Dawley rats were used to establish in vivo Wallerian degeneration model of CNS by ipsilateral motor-sensory cortex ablation. 5 days after cortex ablation, multiecho-T{sub 2} relaxometry and multi-b value DWI were acquired by using a 7 T MR imaging scanner. ADC-map and T{sub 2}-map were reconstructed by post-processing. ROIs are selected according to pathway of corticospinal tract from cortex, internal capsule, cerebral peduncle, pons, medulla oblongata to upper cervical spinal cord to measure ADC value and T{sub 2} relaxation time of healthy side and affected side. The results were compared between the side with cortical ablation and the side without ablation. Results: Excluding ablated cortex, ADC values of the corticospinal tract were significantly increased (P < 0.05) in affected side compared to the unaffected, healthy side; no difference in T{sub 2} relaxation time was observed between the affected and healthy sides. Imaging findings were correlated with histological examinations. Conclusion: As shown in this animal experiment, ADC values could non-invasively demonstrate the secondary degeneration involving descending white matter tracts. ADC values are more sensitive indicators for detection of early WD than T{sub 2} relaxation time.

  4. Microwave multiplex readout for superconducting sensors

    Energy Technology Data Exchange (ETDEWEB)

    Ferri, E., E-mail: elena.ferri@mib.infn.it [Università Milano-Bicocca, Milan (Italy); INFN Sez. di Milano-Bicocca, Milan (Italy); Becker, D.; Bennett, D. [NIST, Boulder, CO (United States); Faverzani, M. [Università Milano-Bicocca, Milan (Italy); INFN Sez. di Milano-Bicocca, Milan (Italy); Fowler, J.; Gard, J. [NIST, Boulder, CO (United States); Giachero, A. [Università Milano-Bicocca, Milan (Italy); INFN Sez. di Milano-Bicocca, Milan (Italy); Hays-Wehle, J.; Hilton, G. [NIST, Boulder, CO (United States); Maino, M. [Università Milano-Bicocca, Milan (Italy); INFN Sez. di Milano-Bicocca, Milan (Italy); Mates, J. [NIST, Boulder, CO (United States); Puiu, A.; Nucciotti, A. [Università Milano-Bicocca, Milan (Italy); INFN Sez. di Milano-Bicocca, Milan (Italy); Reintsema, C.; Schmidt, D.; Swetz, D.; Ullom, J.; Vale, L. [NIST, Boulder, CO (United States)

    2016-07-11

    The absolute neutrino mass scale is still an outstanding challenge in both particle physics and cosmology. The calorimetric measurement of the energy released in a nuclear beta decay is a powerful tool to determine the effective electron-neutrino mass. In the last years, the progress on low temperature detector technologies has allowed to design large scale experiments aiming at pushing down the sensitivity on the neutrino mass below 1 eV. Even with outstanding performances in both energy (~ eV on keV) and time resolution (~ 1 μs) on the single channel, a large number of detectors working in parallel is required to reach a sub-eV sensitivity. Microwave frequency domain readout is the best available technique to readout large array of low temperature detectors, such as Transition Edge Sensors (TESs) or Microwave Kinetic Inductance Detectors (MKIDs). In this way a multiplex factor of the order of thousands can be reached, limited only by the bandwidth of the available commercial fast digitizers. This microwave multiplexing system will be used to readout the HOLMES detectors, an array of 1000 microcalorimeters based on TES sensors in which the {sup 163}Ho will be implanted. HOLMES is a new experiment for measuring the electron neutrino mass by means of the electron capture (EC) decay of {sup 163}Ho. We present here the microwave frequency multiplex which will be used in the HOLMES experiment and the microwave frequency multiplex used to readout the MKID detectors developed in Milan as well.

  5. A new readout control system for the LHCb upgrade at CERN

    International Nuclear Information System (INIS)

    Alessio, F; Jacobsson, R

    2012-01-01

    The LHCb experiment has proposed an upgrade towards a full 40 MHz readout system in order to run between five and ten times its initial design luminosity. The entire readout architecture will be upgraded in order to cope with higher sub-detector occupancies, higher rate and higher network load. In this paper, we describe the architecture, functionalities and a first hardware implementation of a new fast Readout Control system for the LHCb upgrade, which will be entirely based on FPGAs and bi-directional links. We also outline the real-time implementations of the new Readout Control system, together with solutions on how to handle the synchronous distribution of timing and synchronous information to the complex upgraded LHCb readout architecture. One section will also be dedicated to the control and usage of the newly developed CERN GBT chipset to transmit fast and slow control commands to the upgraded LHCb Front-End electronics. At the end, we outline the plans for the deployment of the system in the global LHCb upgrade readout architecture.

  6. Application of Σ-ΔADC in fluorescence measurement

    International Nuclear Information System (INIS)

    Hao Yan; Chen Ziyu; Shen Ji

    2011-01-01

    It introduces the measurement system of fluorescence intensity, the Σ-ΔADC used as its core components. The system consisted of ADS1255, microcontrollers LPC2368 devices, etc. LPC2368 is used as the control, data process and communication interface. Diagram of the system is given. The linear response experiments, frequency response experiments, measurement accuracy experiments and long-time stability experiments were carried out. Experiments show that the system reaches a good linear response, and the measurement accuracy reaches up to 0.01%. (authors)

  7. Very High-Performance Advanced Filter Bank Analog-to-Digital Converter (AFB ADC) Project

    National Research Council Canada - National Science Library

    Velazquez, Scott

    1999-01-01

    ... of the art by using a parallel array of individual commercial off the shelf converters. The significant performance improvements afforded by the Advanced Filter Bank Analog to Digital Converter (AFB ADC...

  8. Diffusion-weighted magnetic resonance imaging for the initial characterization of non-fatty soft tissue tumors: correlation between T2 signal intensity and ADC values

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto [Service d' Imagerie Guilloz, CHU Nancy, Nancy (France); Universite de Lorraine, IADI, UMR S 947, Vandoeuvre-les-Nancy (France); Gay, Frederique; Blum, Alain [Service d' Imagerie Guilloz, CHU Nancy, Nancy (France); Chen, Bailiang; Felblinger, Jacques [Universite de Lorraine, IADI, UMR S 947, Vandoeuvre-les-Nancy (France); Zins, Marie [University Versailles St-Quentin, Versailles (France); Inserm, Centre for research in Epidemiology and Population Health (CESP), U1018, Villejuif (France); Sirveaux, Francois [Centre Chirurgical Emile Galle, Service de Chirurgie Traumatologique et Orthopedique, Nancy (France)

    2016-02-15

    To evaluate the performance of quantitative diffusion-weighted imaging (DWI) correlated with T2 signal in differentiating non-fatty benign from malignant tumors. A total of 76 patients with a histologically confirmed non-fatty soft tissue tumors (46 benign and 30 malignant) were prospectively included in this ethics committee approved study. All patients signed an informed consent and underwent MRI with DWI with two b values (0 and 600). ADC values from the solid components of these tumors were obtained and were correlated with the lesion's signal intensity on T2-weighted fat-saturated sequences. ADC values were obtained from adjacent normal muscle to allow calculation of tumor/muscle ADC ratios. There were 58 hyperintense and 18 iso or hypointense lesions. All hypointense lesions were benign. The mean ADC values for benign and malignant tumors were 1.47 ± 0.54 x 10{sup -3} and 1.17 ± 0.38 x 10{sup -3} mm{sup 2}/s respectively (p < 0.005). The mean ADC ratio in benign iso or hypointense tumors was significantly lower than that of hyperintense ones (0.76 ± 0.21 versus 1.58 ± 0.82 - p < 0.0001). An ADC ratio lower than 0.915 was highly specific for malignancy (96.4 %), whereas an ADC ratio higher than 1.32 was highly sensitive for benign lesions (90 %). ADC analysis can be useful in the initial characterization of T2 hyperintense non-fatty soft tissue masses, although this technique alone is not likely to change patient management. (orig.)

  9. Comparison of ADC map with trace map in the normal and infarct areas of the brains of stroke patients

    International Nuclear Information System (INIS)

    Kim, Seung Hyung; Yoon, Pyeong Ho; Jeong, Eun Kee; Oh, Young Taick; Kim, Dong Ik

    1999-01-01

    To compare ADC mapping with trace mapping in normal and infarct areas of the brains of stroke patients. Eighteen patients diagnosed on the basis of clinical and brain MRI examinations as suffering from brain infarction were included in this study (hyperacute-1, acute-4, subacute-12, chronic-1). Diffusion weighted images of three orthogonal directions of a patient's brain were obtained by means of a single shot EPI pulse sequence, using a diffusion gradient with four serial b-factors. Three ADC maps were then reconstructed by post-image processing and were summed pixel by pixel to yield a trace map. ROIs were selected in the normal areas of white matter, gray matter and CSF of one hemisphere, and other ROIs of the same size were selected at the same site of the contralateral hemisphere. ADC and trace values were measured and right/left ratios of ADC and trace values were calculated. Using these values, we then compared the ADC map with the trace map, and compared the degree of anisotropic diffusion between white matter, gray matter and CSF. Except for three, whose infarct lesions were small and lay over white and gray matter, patients were divided into two groups. Those with infarct in the white matter (n=10) were assigned to one group, and those with infarct in the gray matter (n=5) to the other. ROIs were selected in the infarct area and other ROIs of the same size were selected at the same site of the contralateral hemisphere. ADC and trace values were measured and infarct/contralateral ratios were calculated. We then compared ADC ratio with trace ratio in white matter and gray matter infarct. In normal white matter, the Dxx ratio was 0.980±0.098, the Dyy ratio 1.019±0.086, the Dzz ratio 0.999±0.111, and the trace ratio 0.995±0.031. In normal gray matter, the Dxx ratio was 1.001±0.058, the Dyy ratio 0.996±0.063, Dzz ratio 1.005±0.070, and the trace ratio 1.001±0.028. In CSF, the Dxx ratio was 1.002±0.064, the Dyy ratio 1.023±0.055, the Dzz ratio 0.999

  10. The correlation between biological activity and diffusion-weighted MR imaging and ADC value in cases with prostate cancer.

    Science.gov (United States)

    Sokmen, Bedriye Koyuncu; Sokmen, Dogukan; Ucar, Nese; Ozkurt, Huseyin; Simsek, Abdulmuttalip

    2017-12-31

    Firstly, we aimed to investigate the correlation among dynamic contrasted magnetic resonance (MR) images, diffusion-weighted MR images, and apparent diffusion coefficent (ADC) values in patients with prostate cancer. Secondly, we aimed to investigate the roles of these variables on clinical risk classification and the biological behavior of the prostate cancer. A total of sixty with prostatic adenocarcinoma patients diagnosed between January 2011 and May 2013 were retrospectively included in the study. Risk classification of patients were evaluated as low-risk (Group 1) (n = 20) (Stage T1c-T2a, PSA T3a, PSA > 20 ng/ml, Gleason Score > 7). Diffusion-weighted MR images, dynamic contrasted MR images, and ADC values of the prostates were correlated. ADC values of the cases in Group 3 were lower than those of the other groups (p values of the areas without malignancy did not differ significantly between groups (p > 0.05). Biological activity of the tumor tissue was determined by GS, while a negative correlation was observed between GSs and ADC values of the patients, (p values were obtained. These measured values can play a role in the noninvasive determination of the cellularity of the tumoral mass.

  11. Charge-sharing SAR ADCs for low-voltage low-power applications

    CERN Document Server

    Rabuske, Taimur

    2017-01-01

    This book introduces readers to the potential of charge-sharing (CS) successive approximation register (SAR) analog-to-digital converters (ADCs), while providing extensive analysis of the factors that limit the performance of the CS topology. The authors present guidelines and useful techniques for mitigating the limitations of the architecture, while focusing on the implementation under restricted power budgets and voltage supplies.

  12. The changes of 18F-FDG uptake and ADC value of the normal endometrium during the menstrual cycle

    International Nuclear Information System (INIS)

    Seko, Ayumi; Kanasaki, Shuzou; Kitahara, Sawako; Murata, Kiyoshi; Tatsumi, Mitsuaki; Hayashida, Kohei; Sakashita, Yoko; Hamanaka, Yasuyo

    2007-01-01

    We evaluated the normal endometrium of reproductive age using positron emission tomography (PET)/CT and Diffusion-weighted MR imaging. 18 F-fluorodeoxyglucose (FDG) uptake and apparent diffusion coefficient (ADC) value were classified according to the menstrual cycle. On PET/CT, FDG uptake was significant high at the menstrual and ovulatory phase. On diffusion-weighted imaging (DWI), ADC value was significant low at the menstrual phase. (author)

  13. Chemical and biological studies of Lobelia flaccida (C. Presl) A.DC ...

    African Journals Online (AJOL)

    Chemical and biological studies of Lobelia flaccida (C. Presl) A.DC leaf: a medicinal plant used by traditional healers in Eastern Cape, South Africa. ... (85 mg/kg, intraperitoneally)-induced convulsion model in mice, normal saline and diazepam (1 mg/kg, i.p.) served as negative and positive control groups respectively.

  14. Yarr: A PCIe based readout system for semiconductor tracking systems

    Energy Technology Data Exchange (ETDEWEB)

    Heim, Timon [Bergische Universitaet Wuppertal, Wuppertal (Germany); CERN, Geneva (Switzerland); Maettig, Peter [Bergische Universitaet Wuppertal, Wuppertal (Germany); Pernegger, Heinz [CERN, Geneva (Switzerland)

    2015-07-01

    The Yarr readout system is a novel DAQ concept, using an FPGA board connected via PCIe to a computer, to read out semiconductor tracking systems. The system uses the FPGA as a reconfigurable IO interface which, in conjunction with the very high speed of the PCIe bus, enables a focus of processing the data stream coming from the pixel detector in software. Modern computer system could potentially make the need of custom signal processing hardware in readout systems obsolete and the Yarr readout system showcases this for FE-I4 chips, which are state-of-the-art readout chips used in the ATLAS Pixel Insertable B-Layer and developed for tracking in high multiplicity environments. The underlying concept of the Yarr readout system tries to move intelligence from hardware into the software without the loss of performance, which is made possible by modern multi-core processors. The FPGA board firmware acts like a buffer and does no further processing of the data stream, enabling rapid integration of new hardware due to minimal firmware minimisation.

  15. A read-out buffer prototype for ATLAS high level triggers

    CERN Document Server

    Calvet, D; Huet, M; Le Dû, P; Mandjavidze, I D; Mur, M

    2000-01-01

    Read-Out Buffers are critical components in the dataflow chain of the ATLAS Trigger/DAQ system. At up to 75 kHz, after each Level-1 trigger accept signal, these devices receive and store digitized data from groups of front-end electronic channels. Several Read-Out Buffers are grouped to form a Read-Out Buffer Complex that acts as a data server for the High Level Triggers selection algorithms and for the final data collection system. This paper describes a functional prototype of a Read-Out Buffer based on a custom made PCI mezzanine card that is designed to accept input data at up to 160 MB/s, to store up to 8 MB of data and to distribute data chunks at the desired request rate. We describe the hardware of the card that is based on an Intel I960 processor and CPLDs. We present the integration of several of these cards in a Read-Out Buffer Complex. We measure various performance figures and we discuss to which extent these can fulfill ATLAS needs. 5 Refs.

  16. Multifunctional data acquisition system based on USB and FPGA

    International Nuclear Information System (INIS)

    Huang Tuchen; Gong Hui; Shao Beibei

    2013-01-01

    A multifunctional data acquisition system based on USB and FPGA was developed. The system has four analog inputs digitalized by fast ADC. Based on flexibility of FPGA, different functions can be implemented such as waveform sampling, pulse counting, multi-channel pulse height analysis, and charge division readout process. The hardware communicates with host PC via USB interface. The Labview based user soft ware initializes the hardware, configures the running parameters, reads and processes the data as well as displays the result online. (authors)

  17. Recent Results of the BGO-OD Experiment at ELSA Facility

    Science.gov (United States)

    De Leo, Veronica; Bantes, B.; Bayadilov, D.; Beck, R.; Becker, M.; Bella, A.; Bieling, J.; Boese, S.; Braghieri, A.; Brinkmann, K.; Burdeynyi, D.; Curciarello, F.; Di Salvo, R.; Dutz, H.; Elsner, D.; Fantini, A.; Frese, T.; Frommberger, F.; Ganenko, V.; Gervino, G.; Ghio, F.; Giardina, G.; Girolami, B.; Glazier, D.; Goertz, S.; Gridnev, A.; Hammann, D.; Hannappel, J.; Hillert, W.; Ignatov, A.; Jahn, O.; Jahn, R.; Joosten, R.; Jude, T. C.; Klein, F.; Koop, K.; Krusche, B.; Lapik, A.; Levi Sandri, P.; Lopatin, I.; Mandaglio, G.; Messi, F.; Messi, R.; Moricciani, D.; Nedorezov, V.; Noviskiy, D.; Pedroni, P.; Romaniuk, M.; Rostomyan, T.; Schaerf, C.; Schmieden, H.; Sumachev, V.; Tarakanov, V.; Vegna, V.; Vlasov, P.; Walther, D.; Watts, D.; Zaunick, H.-G.; Zimmermann, T.

    2013-03-01

    The results obtained at the BGO-OD experiment with the BGO calorimeter, equipped with the new electronic readout based on sampling ADCs, during the tests performed with the beam time of March and June 2012 are presented. The proper functioning of the apparatus has allowed the reconstruction of the pseudo-scalar mesons π0 and η invariant masses. The simulation of the η' photoproduction reaction prepared for a proposal to the joint ELSA-MAMI Physics Advisory Committee is also presented.

  18. Optimization of the multilinear compression function applied to calorimetry

    International Nuclear Information System (INIS)

    Cattaneo, P.W.Paolo Walter

    2002-01-01

    The energy dynamic range required by a calorimeter with high speed readout may exceed existing ADC capability. A solution may be a dynamic compressor matching the energy span to the ADC range, such as to contribute at most a predefinite amount to the calorimeter resolution. A multilinear compression function is the easiest to implement, therefore it is interesting to optimize the input to output relation and fix the break points

  19. Multi-channel Waveform Sampling ASIC for radiation detection and measurement

    International Nuclear Information System (INIS)

    Shimazoe, K.; Takahashi, H.; Yeom, J.Y.; Furumiya, T.; Ohi, J.

    2013-01-01

    We have designed and fabricated a 16-channel Waveform Sampling ASIC for radiation detection and measurement. Waveform sampling is very important for the pulse shape analysis and discrimination, which is often used in radiation detection to discriminate different radiations such as alpha, beta and gamma rays. One channel of the fabricated ASIC consists of a charge-sensitive preamplifier, a VGA (Variable Gain Amplifier), an ADC (Analog to Digital Converter) and digital circuits. The preamplifier converts the current signal to the voltage signal, and the VGA amplifies the signal to appropriate level for the ADC. The ADC was designed to digitize the waveform with a frequency of 100 MHz and a resolution of 6bits. Digital circuits consist of a free-running ADC and a multiplexer which were designed to convert a digitized 100 MHz/6bit signal to a 200 MHz/3bit one, which is effective for the reduction of the number and for the achievement of the high integration in one chip. This chip was designed and fabricated with 0.35 μm CMOS technology by ROHM and the size of the ASIC is 4.9 mm by 4.9 mm. The design concept and some experimental results are shown in this paper. -- Highlights: ► Waveform sampling (WS) ASIC is newly developed for pulse shape discrimination. ► WS ASIC can be used for radiation measurement and discrimination. ► WS ASIC is fabricated by submicron CMOS technology for 5 mm × 5 mm area. ► WS ASIC achieves high integration and can be used in very limited space

  20. VHDL implementation on histogram with ADC CAMAC module

    International Nuclear Information System (INIS)

    Ruby Santhi, R.; Satyanarayana, V.V.V.; Ajith Kumar, B.P.

    2007-01-01

    Modern nuclear spectroscopy systems the data acquisition and analysis in experimental science have been undergoing major changes because of faster speed and higher resolution. The CAMAC module which is described here is FPGA based 8K x 24 bit Histogram Memory integrated with ADC on a single board has been designed and fabricated. This module accepts input from Spectroscopy Amplifier for Pulse Height Analysis and offers all features single spectra for a few selected parameters. These on line histograms are to monitor the progress of the experiments during on line experiments

  1. Digital radiography using amorphous selenium: photoconductively activated switch (PAS) readout system.

    Science.gov (United States)

    Reznik, Nikita; Komljenovic, Philip T; Germann, Stephen; Rowlands, John A

    2008-03-01

    A new amorphous selenium (a-Se) digital radiography detector is introduced. The proposed detector generates a charge image in the a-Se layer in a conventional manner, which is stored on electrode pixels at the surface of the a-Se layer. A novel method, called photoconductively activated switch (PAS), is used to read out the latent x-ray charge image. The PAS readout method uses lateral photoconduction at the a-Se surface which is a revolutionary modification of the bulk photoinduced discharge (PID) methods. The PAS method addresses and eliminates the fundamental weaknesses of the PID methods--long readout times and high readout noise--while maintaining the structural simplicity and high resolution for which PID optical readout systems are noted. The photoconduction properties of the a-Se surface were investigated and the geometrical design for the electrode pixels for a PAS radiography system was determined. This design was implemented in a single pixel PAS evaluation system. The results show that the PAS x-ray induced output charge signal was reproducible and depended linearly on the x-ray exposure in the diagnostic exposure range. Furthermore, the readout was reasonably rapid (10 ms for pixel discharge). The proposed detector allows readout of half a pixel row at a time (odd pixels followed by even pixels), thus permitting the readout of a complete image in 30 s for a 40 cm x 40 cm detector with the potential of reducing that time by using greater readout light intensity. This demonstrates that a-Se based x-ray detectors using photoconductively activated switches could form a basis for a practical integrated digital radiography system.

  2. High-Speed, Low-Power ADC for Digital Beam Forming (DBF) Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop Group will design a high-speed, low-power silicon germanium (SiGe)-based, analog-to-digital converter (ADC) to be a key element for digital beam forming...

  3. A 10-bit 200-kS/s SAR ADC IP core for a touch screen SoC

    International Nuclear Information System (INIS)

    Tong Xingyuan; Yang Yintang; Zhu Zhangming; Sheng Wenfang

    2010-01-01

    Based on a 5 MSBs (most-significant-bits)-plus-5 LSBs (least-significant-bits) C-R hybrid D/A conversion and low-offset pseudo-differential comparison approach, with capacitor array axially symmetric layout topology and resistor string low gradient mismatch placement method, an 8-channel 10-bit 200-kS/s SAR ADC (successive-approximation-register analog-to-digital converter) IP core for a touch screen SoC (system-on-chip) is implemented in a 0.18 μm 1P5M CMOS logic process. Design considerations for the touch screen SAR ADC are included. With a 1.8 V power supply, the DNL (differential non-linearity) and INL (integral non-linearity) of this converter are measured to be about 0.32 LSB and 0.81 LSB respectively. With an input frequency of 91 kHz at 200-kS/s sampling rate, the spurious-free dynamic range and effective-number-of-bits are measured to be 63.2 dB and 9.15 bits respectively, and the power is about 136 μW. This converter occupies an area of about 0.08 mm 2 . The design results show that it is very suitable for touch screen SoC applications. (semiconductor integrated circuits)

  4. A novel low-voltage operational amplifier for low-power pipelined ADCs

    International Nuclear Information System (INIS)

    Fan Mingjun; Ren Junyan; Guo Yao; Li Ning; Ye Fan; Li Lian

    2009-01-01

    A novel low-voltage two-stage operational amplifier employing class-AB architecture is presented. The structure utilizes level-shifters and current mirrors to create the class-AB behavior in the first and second stages. With this structure, the transconductances of the two stages are double compared with the normal configuration without class-AB behaviors with the same current consumption. Thus power can be saved and the operation frequency can be increased. The nested cascode miller compensation and symmetric common-mode feedback circuits are used for large unit-gain bandwidth, good phase margin and stability. Simulation results show that the sample-and-hold of the 12-bit 40-Ms/s pipelined ADC using the proposed amplifier consumes only 5.8 mW from 1.2 V power supply with signal-to-noise-and-distortion ratio 89.5 dB, spurious-free dynamic range 95.7 dB and total harmonic distortion -94.3 dB with Nyquist input signal frequency.

  5. A Triggerless readout system for the ANDA electromagnetic calorimeter

    NARCIS (Netherlands)

    Tiemens, M.

    2015-01-01

    One of the physics goals of the future ANDA experiment at FAIR is to research newly discovered exotic states. Because the detector response created by these particles is very similar to the background channels, a new type of data readout had to be developed, called "triggerless" readout. In this

  6. Superresolution near-field readout in phase-change optical disk data storage

    International Nuclear Information System (INIS)

    Peng Chubing

    2001-01-01

    Readout of a phase-change optical disk with a superresolution (SR) near-field structure (Super-RENS) is theoretically examined on the basis of three-dimensional, full-wave vector diffraction theory. Calculations have demonstrated that Super-RENS has a high spatial resolution beyond the diffraction limit in readout. The read signal is dependent on the nature of SR, the layer structure of the disk, and the state of polarization of the incident laser beam. For the Super-RENS in which antimony is used for SR readout, the readout signal is quite small, and the estimated carrier-to-noise ratio (CNR) is only ∼30 dB for marks of 300 nm. For the Super-RENS in which a metallic region is formed during readout, the read signal is large, and the CNR can be as high as 50 dB in reading 300-nm marks

  7. Optical readout method for solid-state dosemeters

    International Nuclear Information System (INIS)

    McDonald, J.C.; Eichner, F.N.; Stahl, K.A.; Miller, S.D.

    1986-07-01

    The readout of solid-state dosemeters is usually accomplished by heating to produce thermoluminescence. This technique has several disadvantages including stressing the dosemeter crystals, melting Teflon enclosures, and destroying the thin dosemeters designed for beta particle measurements. An optical readout method is being developed to avoid these difficulties. Standard dosemeters were irradiated to a dose of approximately 0.02 Sv with 137 Cs gamma rays. The dosemeters were then irradiated with light produced by a high-intensity xenon lamp. Various wavelength bands, from the ultraviolet through the visible and to the near-infrared, were used. The degree of trap emptying was found to be proportional to the total optical power incident. With the intensities used in the preliminary experiments, over 90% trap emptying was achieved. This new technique will prove useful for dosemeters that are encased in plastic for automatic processing. The details of this optical readout method, along with some possible applications in neutron and beta dosimetry are described. 7 refs., 3 figs

  8. High-Speed, Low-Power ADC for Digital Beam Forming (DBF) Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase 1, Ridgetop Group designed a high-speed, yet low-power silicon germanium (SiGe)-based, analog-to-digital converter (ADC) to be a key element for digital...

  9. Description of the SAltro-16 chip for gas detector readout

    CERN Document Server

    Aspell, P; Garcia Garcia, E; de Gaspari, M; Mager, M; Musa, L; Rehman, A; Trampitsch, G

    2010-01-01

    The S-ALTRO prototype chip is a mixed-signal integrated circuit designed to be one of the building blocks of the readout electronics for gas detectors. Its architecture is based in the ALTRO (ALICE TPC Read Out) chip, being its main difference the integration of the charge shaping amplifier in the same IC. Just like ALTRO chip, the prototype architecture and programmability make it suitable for the readout of a wider class of detectors. In one single chip, 16 analogue signals from the detector are shaped, digitised, processed, compressed and stored in a multi-acquisition memory. The Analogue-to- Digital converters embedded in the chip have a 10-bit dynamic range and a maximum sampling rate up to 40MHz. After digitisation, a pipelined Data Processor is able to remove from the input signal a wide range of perturbations, related to the non- ideal behaviour of the detector, temperature variation of the electronics, environmental noise, etc. Moreover, the Data Processor is able to suppress the pulse tail within 1�...

  10. Diffusion tensor imaging of the median nerve at 3.0 T using different MR scanners: Agreement of FA and ADC measurements

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Nanz, Daniel; Bussmann, Lorenz; Chhabra, Avneesh; Fischer, Michael A.; Hodler, Jürg; Pfirrmann, Christian W.A.; Andreisek, Gustav

    2013-01-01

    Objective: To assess the agreement of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values of the median nerve on 3.0 T MR scanners from different vendors. Materials and methods: IRB approved study including 16 healthy volunteers (9 women; mean age 30.6 ± 5.3 years). Diffusion tensor imaging (DTI) of the dominant wrist was performed on three 3.0 T MR scanners (GE, Siemens, Philips) using similar imaging protocols and vendor-proprietary hard- and software. Intra-, inter-reader and inter-vendor agreements were assessed. Results: ICCs for intra-/inter-reader agreements ranged from 0.843–0.970/0.846–0.956 for FA, and 0.840–0.940/0.726–0.929 for ADC, respectively. ANOVA analysis identified significant differences for FA/ADC measurements among vendors (p −3 mm 2 /s (SD ± 0.134 × 10 −3 ) for ADC. A significant negative measurement bias was found for FA values from the GE scanner (−0.05 and −0.07) and for ADC values from the Siemens scanner (−0.053 and −0.063 × 10 −3 mm 2 /s) as compared to the remainder vendors Conclusion: FA and ADC values of the median nerve obtained on different 3.0 T MR scanners differ significantly, but are in comparison to the standard deviation of absolute values small enough to not have an impact on larger group studies or when substantial diffusion changes can be expected. However, caution is warranted in an individual patient when interpreting diffusion values from different scanner acquisitions

  11. Status of readout integrated circuits for radiation detector

    International Nuclear Information System (INIS)

    Moon, B. S.; Hong, S. B.; Cheng, J. E. and others

    2001-09-01

    In this report, we describe the current status of readout integrated circuits developed for radiation detectors, along with new technologies being applied to this field. The current status of ASCIC chip development related to the readout electronics is also included in this report. Major sources of this report are from product catalogs and web sites of the related industries. In the field of semiconductor process technology in Korea, the current status of the multi-project wafer(MPW) of IDEC, the multi-project chip(MPC) of ISRC and other domestic semiconductor process industries is described. In the case of other countries, the status of the MPW of MOSIS in USA and the MPW of EUROPRACTICE in Europe is studied. This report also describes the technologies and products of readout integrated circuits of industries worldwide

  12. Auxiliary controller for time-to-digital converter module readout

    International Nuclear Information System (INIS)

    Ermolin, Yu.V.

    1992-01-01

    The KD-225 auxiliary controller for time-to-digital converter module readout in the SUMMA crate is described. After readout and preliminary processing the data are written in the P-140 buffer memory module. The controller is used in the FODS-2 experimental setup data acquisition system. 12 refs.; 1 fig

  13. Optimization of MKID noise performance via readout technique for astronomical applications

    Science.gov (United States)

    Czakon, Nicole G.; Schlaerth, James A.; Day, Peter K.; Downes, Thomas P.; Duan, Ran P.; Gao, Jiansong; Glenn, Jason; Golwala, Sunil R.; Hollister, Matt I.; LeDuc, Henry G.; Mazin, Benjamin A.; Maloney, Philip R.; Noroozian, Omid; Nguyen, Hien T.; Sayers, Jack; Siegel, Seth; Vaillancourt, John E.; Vayonakis, Anastasios; Wilson, Philip R.; Zmuidzinas, Jonas

    2010-07-01

    Detectors employing superconducting microwave kinetic inductance detectors (MKIDs) can be read out by measuring changes in either the resonator frequency or dissipation. We will discuss the pros and cons of both methods, in particular, the readout method strategies being explored for the Multiwavelength Sub/millimeter Inductance Camera (MUSIC) to be commissioned at the CSO in 2010. As predicted theoretically and observed experimentally, the frequency responsivity is larger than the dissipation responsivity, by a factor of 2-4 under typical conditions. In the absence of any other noise contributions, it should be easier to overcome amplifier noise by simply using frequency readout. The resonators, however, exhibit excess frequency noise which has been ascribed to a surface distribution of two-level fluctuators sensitive to specific device geometries and fabrication techniques. Impressive dark noise performance has been achieved using modified resonator geometries employing interdigitated capacitors (IDCs). To date, our noise measurement and modeling efforts have assumed an onresonance readout, with the carrier power set well below the nonlinear regime. Several experimental indicators suggested to us that the optimal readout technique may in fact require a higher readout power, with the carrier tuned somewhat off resonance, and that a careful systematic study of the optimal readout conditions was needed. We will present the results of such a study, and discuss the optimum readout conditions as well as the performance that can be achieved relative to BLIP.

  14. Infrared readout electronics; Proceedings of the Meeting, Orlando, FL, Apr. 21, 22, 1992

    Science.gov (United States)

    Fossum, Eric R.

    The present volume on IR readout electronics discusses cryogenic readout using silicon devices, cryogenic readout using III-V and LTS devices, multiplexers for higher temperatures, and focal-plane signal processing electronics. Attention is given to the optimization of cryogenic CMOS processes for sub-10-K applications, cryogenic measurements of aerojet GaAs n-JFETs, inP-based heterostructure device technology for ultracold readout applications, and a three-terminal semiconductor-superconductor transimpedance amplifier. Topics addressed include unfulfilled needs in IR astronomy focal-plane readout electronics, IR readout integrated circuit technology for tactical missile systems, and radiation-hardened 10-bit A/D for FPA signal processing. Also discussed are the implementation of a noise reduction circuit for spaceflight IR spectrometers, a real-time processor for staring receivers, and a fiber-optic link design for INMOS transputers.

  15. A digital Front-End and Readout MIcrosystem for calorimetry at LHC

    CERN Multimedia

    2002-01-01

    % RD-16 A Digital Front-End and Readout Microsystem for Calorimetry at LHC \\\\ \\\\Front-end signal processing for calorimetric detectors is essential in order to achieve adequate selectivity in the trigger function of an LHC experiment, with data identification and compaction before readout being required in the harsh, high rate environment of a high luminosity hadron machine. Other crucial considerations are the extremely wide dynamic range and bandwidth requirements, as well as the volume of data to be transferred to following stages of the trigger and readout system. These requirements are best met by an early digitalization of the detector information, followed by integrated digital signal processing and buffering functions covering the trigger latencies.\\\\ \\\\The FERMI (Front-End Readout MIcrosystem) is a digital implementation of the front-end and readout electronic chain for calorimeters. It is based on dynamic range compression, high speed A to D converters, a fully programmable pipeline/digital filter c...

  16. Development of an external readout electronics for a hybrid photon detector

    CERN Document Server

    Uyttenhove, Simon; Tichon, Jacques; Garcia, Salvador

    The pixel hybrid photon detectors currently installed in the LHCb Cherenkov system encapsulate readout electronics in the vacuum tube envelope. The LHCb upgrade and the new trigger system will require their replacement with new photon detectors. The baseline photon detector candidate is the multi-anode photomultiplier. A hybrid photon detector with external readout electronics has been proposed as a backup option. This master thesis covers a R & D phase to investigate this latter concept. Extensive studies of the initial electronics system underlined the noise contributions from the Beetle chip used as front-end readout ASIC and from the ceramic carrier of the photon detector. New front-end electronic boards have been developed and made fully compatible with the existing LHCb-RICH infrastructure. With this compact readout system, Cherenkov photons have been successfully detected in a real particle beam environment. The proof-of-concept of a hybrid photon detector with external readout electronics was val...

  17. Development of telescope readout system based on FELIX for testbeam experiments

    CERN Document Server

    Wu, Weihao; Chen, Hucheng; Chen, Kai; Lacobucci, Giuseppe; Lanni, Francessco; Liu, Hongbin; Barrero Pinto, Mateus Vicente; Xu, Lailin

    2017-01-01

    The High Voltage CMOS (HV-CMOS) sensors are extensively investigated by the ATLAS collaboration in the High-Luminosity LHC (HL-LHC) upgrade of the Inner Tracker (ITk) detector. A testbeam telescope, based on the ATLAS IBL (Insertable B-Layer) silicon pixel modules, has been built to characterize the HV-CMOS sensor prototypes. The Front-End LInk eXchange (FELIX) system is a new approach to function as the gateway between front-ends and the commodity switched network in the different detectors of the ATLAS upgrade. A FELIX based readout system has been developed for the readout of the testbeam telescope, which includes a Telescope Readout FMC Card as interface between the IBL DC (double-chip) modules and a Xilinx ZC706 evaluation board. The test results show that the FELIX based telescope readout system is capable of sensor calibration and readout of a high-density pixel detector in test beam experiments in an effective way.

  18. SiGe 130 nm-based Rad-Hard ADC for the JEO Mission, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Ridgetop will demonstrate the feasibility of developing a radiation-hardened analog-to-digital converter (ADC) suitable for the Jupiter Europa Orbiter mission. This...

  19. CMOS Active-Pixel Image Sensor With Intensity-Driven Readout

    Science.gov (United States)

    Langenbacher, Harry T.; Fossum, Eric R.; Kemeny, Sabrina

    1996-01-01

    Proposed complementary metal oxide/semiconductor (CMOS) integrated-circuit image sensor automatically provides readouts from pixels in order of decreasing illumination intensity. Sensor operated in integration mode. Particularly useful in number of image-sensing tasks, including diffractive laser range-finding, three-dimensional imaging, event-driven readout of sparse sensor arrays, and star tracking.

  20. dc readout experiment at the Caltech 40m prototype interferometer

    International Nuclear Information System (INIS)

    Ward, R L; Adhikari, R; Abbott, B; Abbott, R; Bork, R; Fricke, T; Heefner, J; Ivanov, A; Miyakawa, O; Smith, M; Taylor, R; Vass, S; Waldman, S; Weinstein, A; Barron, D; Frolov, V; McKenzie, K; Slagmolen, B

    2008-01-01

    The Laser Interferometer Gravitational Wave Observatory (LIGO) operates a 40m prototype interferometer on the Caltech campus. The primary mission of the prototype is to serve as an experimental testbed for upgrades to the LIGO interferometers and for gaining experience with advanced interferometric techniques, including detuned resonant sideband extraction (i.e. signal recycling) and dc readout (optical homodyne detection). The former technique will be employed in Advanced LIGO, and the latter in both Enhanced and Advanced LIGO. Using dc readout for gravitational wave signal extraction has several technical advantages, including reduced laser and oscillator noise couplings as well as reduced shot noise, when compared to the traditional rf readout technique (optical heterodyne detection) currently in use in large-scale ground-based interferometric gravitational wave detectors. The Caltech 40m laboratory is currently prototyping a dc readout system for a fully suspended interferometric gravitational wave detector. The system includes an optical filter cavity at the interferometer's output port, and the associated controls and optics to ensure that the filter cavity is optimally coupled to the interferometer. We present the results of measurements to characterize noise couplings in rf and dc readout using this system

  1. Performance tests of developed silicon strip detector by using a 150 GeV electron beam

    International Nuclear Information System (INIS)

    Hyun, Hyojung; Jung, Sunwoo; Kah, Dongha; Kang, Heedong; Kim, Hongjoo; Park, Hwanbae

    2008-01-01

    We manufactured and characterized a silicon micro-strip detector to be used in a beam tracker. A silicon detector features a DC-coupled silicon strip sensor with VA1 Prime2 analog readout chips. The silicon strip sensors have been fabricated on 5-in. wafers at Electronics and Telecommunications Research Institute (Daejeon, Korea). The silicon strip sensor is single-sided and has 32 channels with a 1 mm pitch, and its active area is 3.2 by 3.2 cm 2 with 380 μm thickness. The readout electronics consists of VA hybrid, VA Interface, and FlashADC and Control boards. Analog signals from the silicon strip sensor were being processed by the analog readout chips on the VA hybrid board. Analog signals were then changed into digital signals by a 12 bit 25 MHz FlashADC. The digital signals were read out by the Linux-operating PC through the FlashADC-USB2 interface. The DAQ system and analysis programs were written in the framework of ROOT package. The beam test with the silicon detector had been performed at CERN beam facility. We used a 150 GeV electron beam out of the SPS(Super Proton Synchrotron) H2 beam line. We present beam test setup and measurement result of signal-to-noise ratio of each strip channel. (author)

  2. Characterization of a DAQ system for the readout of a SiPM based shashlik calorimeter

    International Nuclear Information System (INIS)

    Berra, A.; Bonvicini, V.; Bosisio, L.; Lietti, D.; Penzo, A.; Prest, M.; Rabaioli, S.; Rashevskaya, I.; Vallazza, E.

    2014-01-01

    Silicon PhotoMultipliers (SiPMs) are a recently developed type of silicon photodetector characterized by high gain and insensitivity to magnetic fields, which make them a suitable detector for the next generation high energy and space physics experiments. This paper presents the performance of a readout system for SiPMs based on the MAROC3 ASIC. The ASIC consists of 64 channels working in parallel, each one with a variable gain pre-amplifier, a tunable slow shaper with a sample and hold circuit for the analog readout and a tunable fast shaper for the digital one. In the tests described in this paper, only the analog part of the ASIC has been used. A frontend board based on the MAROC3 ASIC has been tested at CERN coupled to a scintillator-lead shashlik calorimeter, readout with 36 large area SiPMs. The performance of the system has been characterized in terms of linearity and energy resolution on the CERN PS-T9 and SPS-H2 beamlines, using different configurations of the ASIC parameters

  3. Whole-tumor apparent diffusion coefficient (ADC) histogram analysis to differentiate benign peripheral neurogenic tumors from soft tissue sarcomas.

    Science.gov (United States)

    Nakajo, Masanori; Fukukura, Yoshihiko; Hakamada, Hiroto; Yoneyama, Tomohide; Kamimura, Kiyohisa; Nagano, Satoshi; Nakajo, Masayuki; Yoshiura, Takashi

    2018-02-22

    Apparent diffusion coefficient (ADC) histogram analyses have been used to differentiate tumor grades and predict therapeutic responses in various anatomic sites with moderate success. To determine the ability of diffusion-weighted imaging (DWI) with a whole-tumor ADC histogram analysis to differentiate benign peripheral neurogenic tumors (BPNTs) from soft tissue sarcomas (STSs). Retrospective study, single institution. In all, 25 BPNTs and 31 STSs. Two-b value DWI (b-values = 0, 1000s/mm 2 ) was at 3.0T. The histogram parameters of whole-tumor for ADC were calculated by two radiologists and compared between BPNTs and STSs. Nonparametric tests were performed for comparisons between BPNTs and STSs. P histogram parameters except kurtosis and entropy differed significantly between BPNTs and STSs. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  4. The readout performance evaluation of PowerPC

    International Nuclear Information System (INIS)

    Chu Yuanping; Zhang Hongyu; Zhao Jingwei; Ye Mei; Tao Ning; Zhu Kejun; Tang Suqiu; Guo Yanan

    2003-01-01

    PowerPC, as a powerful low-cost embedded computer, is one of the very important research objects in recent years in the project of BESIII data acquisition system. The researches on the embedded system and embedded computer have achieved many important results in the field of High Energy Physics especially in the data acquisition system. The one of the key points to design an acquisition system using PowerPC is to evaluate the readout ability of PowerPC correctly. The paper introduce some tests for the PowerPC readout performance. (authors)

  5. 3 ns single-shot read-out in a quantum dot-based memory structure

    International Nuclear Information System (INIS)

    Nowozin, T.; Bimberg, D.; Beckel, A.; Lorke, A.; Geller, M.

    2014-01-01

    Fast read-out of two to six charges per dot from the ground and first excited state in a quantum dot (QD)-based memory is demonstrated using a two-dimensional electron gas. Single-shot measurements on modulation-doped field-effect transistor structures with embedded InAs/GaAs QDs show read-out times as short as 3 ns. At low temperature (T = 4.2 K) this read-out time is still limited by the parasitics of the setup and the device structure. Faster read-out times and a larger read-out signal are expected for an improved setup and device structure

  6. ADC3 YANG DIBUAT DENGAN PELEBURAN ULANG ALUMINIUM BEKAS SEBAGAI BAHAN PROPELER KAPAL KAYU

    Directory of Open Access Journals (Sweden)

    Suyanto Suyanto

    2016-11-01

    Full Text Available Saat ini pembuatan propeler aluminium pada industri kecil banyak memanfaatkan bahan dasar aluminium bekas. Namun produk yang dihasilkan belum memenuhi spesifikasi standar material. Penelitian dilakukan dengan menggunakan bahan dasar aluminium siku bekas dan aluminium kampas bekas. Variasi penambahan TiB sebagai grain refiner dilakukan pada saat peleburan. Perhitungan dengan simulasi Excel dilakukan untuk memperkirakan komposisi hasil pengecoran yang sesuai. Pengecoran ulang menghasilkan produk dengan tingkat porositas 3,3 % sampai 5,9 %. Penggunaan cetakan pasir ikut berperan dalam timbulnya porositas. Penambahan TiB sebanyak 0,5% ke ADC3 berpengaruh pada penurunan ukuran butir hingga 50%, peningkatan kekerasan hingga 23%, peningkatan kekuatan tarik hingga 11%, serta penurunan keuletan hingga 20%. Kata kunci: ADC3, pengecoran ulang aluminium, propeler.

  7. Accounting for Dark Current Accumulated during Readout of Hubble's ACS/WFC Detectors

    Science.gov (United States)

    Ryon, Jenna E.; Grogin, Norman A.; Coe, Dan A.; ACS Team

    2018-06-01

    We investigate the properties of excess dark current accumulated during the 100-second full-frame readout of the Advanced Camera for Surveys (ACS) Wide Field Channel (WFC) detectors. This excess dark current, called "readout dark", gives rise to ambient background gradients and hot columns in each ACS/WFC image. While readout dark signal is removed from science images during the bias correction step in CALACS, the additional noise from the readout dark is currently not taken into account. We develop a method to estimate the readout dark noise properties in ACS/WFC observations. We update the error (ERR) extensions of superbias images to include the appropriate noise from the ambient readout dark gradient and stable hot columns. In recent data, this amounts to about 5 e-/pixel added variance in the rows farthest from the WFC serial registers, and about 7 to 30 e-/pixel added variance along the stable hot columns. We also flag unstable hot columns in the superbias data quality (DQ) extensions. The new reference file pipeline for ACS/WFC implements these updates to our superbias creation process.

  8. Design and prototyping of a readout aggregation ASIC

    Energy Technology Data Exchange (ETDEWEB)

    Lemke, Frank; Schatral, Sven; Bruening, Ulrich [ZITI, Universitaet Heidelberg (Germany); Som, Indranil; Bhattacharyya, Tarun [Indian Institute of Technology, Kharagpur (India); Collaboration: CBM-Collaboration

    2015-07-01

    In close collaboration between the Indian Institute of Technology Kharagpur (IITKGP) and the Institute for Computer Engineering (ZITI) at the University of Heidelberg a readout aggregation ASIC was designed. This happened in the context of the Compressed Baryonic Matter (CBM) experiment at the Facility for Antiproton and Ion Research (FAIR). The ASIC is designed in 65nm TSMC technology. Its miniASIC tapeout to verify the analog and high-speed components is scheduled to the first quarter of 2015. This mixed-signal ASIC consists of a full-custom 5Gb/s serializer/deserializer, designed by the IITKGP including design elements such as phase-locked loop, bandgap reference, and clock data recovery, and a digital designed network communication and aggregation part designed by the ZITI. In addition, there are test structures and an I2C readout integrated to ease bring up and monitoring. A specialty of this test ASIC is the aggregation of links featuring different data rates, running with bundles of 500 MB/s LVDS. This enables flexible readout setups of mixed detectors respectively readout of various chips. As communication protocol, a unified link protocol is used including control messages, data messages, and synchronization messages on an identical lane. The design has been simulated, verified, and hardware emulated using Spartan 6 FPGAs.

  9. The use of DWI to assess spleen and liver quantitative ADC changes in the detection of liver fibrosis stages in chronic viral hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Cece, Hasan, E-mail: hasan_cece@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Ercan, Abdulbasit, E-mail: abdulbasitercan@hotmail.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Yıldız, Sema, E-mail: drsemayildiz@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Karakas, Ekrem, E-mail: karakasekrem@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Karakas, Omer, E-mail: dromerkarakas@hotmail.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Boyacı, Fatıma Nurefsan, E-mail: drnurefsan@yahoo.com [Harran University, Faculty of Medicine, Department of Radiology, Sanliurfa (Turkey); Aydogan, Timucin, E-mail: drtaydogan@yahoo.com.tr [Harran University, Faculty of Medicine, Department of Gastroenterology, Sanliurfa (Turkey); Karakas, Emel Yigit, E-mail: e.ygtkarakas@yahoo.com.tr [Sanliurfa Training and Research Hospital, Department of İnternal Medicine, Sanliurfa (Turkey); Cullu, Nesat, E-mail: nesatcullu77@gmail.com [Muğla Sıtkı Koçman University, Faculty of Medicine, Department of Radiology, Mugla (Turkey); Ulas, Turgay, E-mail: turgayulas@yahoo.com [Harran University, Faculty of Medicine, Department of İnternal Medicine, Sanliurfa (Turkey)

    2013-08-15

    This study aimed to evaluate the changes in spleen and liver diffusion-weighted magnetic resonance imaging (DWI) in chronic viral hepatitis patients. The study comprised 47 patients and 30 healthy volunteers. DWIs were obtained. Apparent Diffusion Coefficient (ADC) measurements were made by transferring the images to the workstation. The measurements of value b 1000 were made from a total of five points of the liver and three points of the spleen. Liver biopsy was performed on the 47 patients. The fibrosis stages of the patients were defined according to the METAVIR scoring system. Student's t-test was used in the comparison of mean ages, liver and spleen ADC values between the patient and the control group. Kruskal–Wallis followed by Mann–Whitney U Test with Bonferroni adjustment was performed in the comparison of mean ADC values of the patients at different stages and the control group. A statistically significant difference was determined between the patient and control group in respect of liver and spleen mean ADC values (P < 0.05). F3 group showed a significant difference compared to control and F1 and F4 group showed a significant difference compared to control, F1, F2 and F3 group in terms of the mean liver ADC value (P < 0.01). F3 and F4 group showed a significant difference compared to control and F1 group in terms of the mean spleen ADC value (P < 0.01). As a result we believe that the measurement of liver and spleen ADC values may be an indicator in the determination of the level of fibrosis.

  10. The longitudinal effect of ejaculation on seminal vesicle fluid volume and whole-prostate ADC as measured on prostate MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Tristan; Gallagher, Ferdia A. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospital and University of Cambridge, CamPARI Clinic, Cambridge (United Kingdom); Tanner, James; Gill, Andrew B.; Slough, Rhys A. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Wason, James [University of Cambridge, MRC Biostatistics Unit, Cambridge (United Kingdom)

    2017-12-15

    To prospectively investigate the longitudinal effect of ejaculatory abstinence on MRI-measured seminal vesicle (SV) volume and whole-prostate ADC over consecutive days. 15 healthy male volunteers (mean 35.9 years, range 27-53) underwent 3-T MRI at baseline and 1, 2 and 3 days post-ejaculation. Prostate and SV volumes were derived by volume segmentation and whole-gland apparent diffusion coefficient (ADC) values calculated. A mixed-effects linear regression compared ADC values and prostate/seminal vesicle volumes in each volunteer between studies in a pairwise manner. All subjects completed the four MRIs. Mean prostate volume was 22.45 cm{sup 3} (range 13.04-31.21 cm{sup 3}), with no change between the four studies (p = 0.89-0.99). 13/15 subjects showed SV volume reduction from baseline to day 1, with group-mean decreasing from 6.45 to 4.80 cm{sup 3} (-25.6%, p < 0.001), and a significant reduction from baseline to day 2 (-18.1%, p = 0.002). There was a significant volume increase from both day 1 (+21.3%, p = 0.006) and day 2 (+10.2%, p = 0.022) to day 3 post-ejaculation. There was a significant reduction in ADC from 1.105 at baseline to 1.056 x 10{sup -3} mm{sup 2}/s at day 1 (mean -4.3%, p = 0.009). The longitudinal effect of ejaculation on SV volume was demonstrated. Significant reductions in SV volume and whole-gland ADC were observed post-ejaculation, supporting a 3-day period of abstinence before prostate MRI. (orig.)

  11. ANATOMICAL AND PHYSICAL PROPERTIESOF BISBUL WOOD (Diospyros blancoi A.DC.

    Directory of Open Access Journals (Sweden)

    Krisdianto Krisdianto

    2005-03-01

    Full Text Available Ebony (Diospyros sp.  is a heavy hardwood that is  popularly known as blackwood. Diospyros consists of over 300 species spread throughout tropics area and about 100 species occur in Indonesia. Bisbul wood (Diospyros btancoi A.DC. is one species of  streaked ebony that is locally known as 'buah mentega'.  The anatomical and physical properties of  bisbul  were studied to collect information  for wood identification  and to support appropriate use of the timber. Anatomical properties were studied from microtome sectioned samples, which have been coloured by safranin and mounted by entellan, while fiber dimensions  were studied from macerated samples.  Physical properties  of  bisbul wood studied include moisture content, density and percentage of volumetric shrinkage. Moisture content and density were studied from 20 x 20 x 20 mm samples based on wet and oven dry condition. Volumetric shrinkage was measured from dimension changes in radial, tangential and longitudinal shrinkage of 20 x 20 x 40 mm samples. The samples were measured in wet and oven dry conditions. The main anatomical characteristics to identify bisbul wood were black wood with pinkish streaked, heavy and very hard,  very fine texture, even, lustrous surface and glossy, distinct growth ring, small size of vessels, apotracheal parenchyma forming reticulate pattern. The average moisture content was 59.86 ± 2.84%,  the density average was 0.74 ± 0.04 gr/cm3  and volumetric shrinkage was 10.41±0.70%.   The higher the stem, the more moisture  content and the lower the density will be. Sapwood density was lower and had more moisture  content than heartwood. The black pinkish heavy wood, bisbul was recommended to be used for carvings, sculpture, souvenir and luxuryinterior products.

  12. Readout chip for the CMS pixel detector upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Rossini, Marco, E-mail: marco.rossini@phys.ethz.ch

    2014-11-21

    For the CMS experiment a new pixel detector is planned for installation during the extended shutdown in winter 2016/2017. Among the changes of the detector modified front end electronics will be used for higher efficiency at peak luminosity of the LHC and faster readout. The first prototype versions of the new readout chip have been designed and produced. The results of qualification and calibration for the new chip are presented in this paper.

  13. Handheld readout electronics to fully exploit the particle discrimination capabilities of elpasolite scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Budden, B.S., E-mail: bbudden@lanl.gov [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Stonehill, L.C.; Warniment, A.; Michel, J.; Storms, S.; Dallmann, N.; Coupland, D.D.S.; Stein, P.; Weller, S.; Borges, L.; Proicou, M.; Duran, G. [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Kamto, J. [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Electrical & Computer Engineering Department, Praire View A& M University, Prairie View, TX 77446 (United States)

    2015-09-21

    A new class of elpasolite scintillators has garnered recent attention due to the ability to perform as simultaneous gamma spectrometers and thermal neutron detectors. Such a dual-mode capability is made possible by pulse-shape discrimination (PSD), whereby the emission waveform profiles of gamma and neutron events are fundamentally unique. To take full advantage of these materials, we have developed the Compact Advanced Readout Electronics for Elpasolites (CAREE). This handheld instrument employs a multi-channel PSD-capable ASIC, custom micro-processor board, front-end electronics, power supplies, and a 2 in. photomultiplier tube for readout of the scintillator. The unit is highly configurable to allow for performance optimization amongst a wide sample of elpasolites which provide PSD in fundamentally different ways. We herein provide an introduction to elpasolites, then describe the motivation for the work, mechanical and electronic design, and preliminary performance results.

  14. The Omega Ring Imaging Cerenkov Detector readout system user's guide

    International Nuclear Information System (INIS)

    Hallewell, G.

    1984-11-01

    The manual describes the electronic readout system of the Ring Imaging Cerenkov Detector at the CERN Omega Spectrometer. The system is described in its configuration of September 1984 after the Rich readout system had been used in two Omega experiments. (U.K.)

  15. DWI in breast MRI: Role of ADC value to determine diagnosis between recurrent tumor and surgical scar in operated patients

    Energy Technology Data Exchange (ETDEWEB)

    Rinaldi, Pierluigi, E-mail: pierluigi.rinaldi@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Giuliani, Michela, E-mail: micgiuli@yahoo.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Belli, Paolo, E-mail: pbelli@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Costantini, Melania, E-mail: mcostantini@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Romani, Maurizio, E-mail: mromani@rm.unicatt.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Distefano, Daniela, E-mail: daniela_distefano@hotmail.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Bufi, Enida, E-mail: reagandus@alice.i [Department of Bio-Imaging and Radiological Sciences, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Mule, Antonino, E-mail: amule@rm.unicatt.i [Division of Pathology and Histology, Catholic University - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Magno, Stefano, E-mail: smagno@rm.unicatt.i [Department of Surgery, Breast Unit, Catholic University Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Masetti, Riccardo, E-mail: riccardo.masetti@rm.unicatt.i [Department of Surgery, Breast Unit, Catholic University Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy); Bonomo, Lorenzo, E-mail: lbonomo@rm.unicatt.i [Dept. of Bio-Imaging and Radiological Sciences, Catholic Univ. - Policlinic A. Gemelli, L.go A. Gemelli 8, 00168 Rome (Italy)

    2010-08-15

    Introduction: Purpose of our study is to evaluate the role of the apparent diffusion coefficient (ADC) in the diagnosis of recurrent tumor on the scar in patients operated for breast cancer. Assess, therefore, the weight of diagnostic diffusion echo-planar sequence, in association with the morphological and dynamic sequences in the diagnosis of tumor recurrence versus surgical scar. Materials and methods: From September 2007 to March 2009, 72 patients operated for breast cancer with suspected recurrence on the scar were consecutively subjected to magnetic resonance imaging (MRI), including use of a diffusion sequence. All patients with pathological enhancement in the scar were then subjected to histological typing. MRI was considered negative in the absence of areas of suspicious enhancement. In all cases it was measured the ADC value in the scar area or in the area with pathological enhancement. The ADC values were compared with MRI findings and histological results obtained. Results: 26 cases were positive/doubtful at MRI and then subjected to histological typing: of these recurrences were 20 and benign were 6. 46 cases were judged negative at MRI and therefore not sent to cyto-histology. The average ADC value of recurrences was statistically lower of scarring (p < 0.001). Conclusions: ADC value can be a specific parameter in differential diagnosis between recurrence and scar. The diffusion sequence, in association with the morphological and dynamic sequences, can be considered a promising tool for the surgical indication in suspected recurrence of breast cancer.

  16. DWI in breast MRI: Role of ADC value to determine diagnosis between recurrent tumor and surgical scar in operated patients

    International Nuclear Information System (INIS)

    Rinaldi, Pierluigi; Giuliani, Michela; Belli, Paolo; Costantini, Melania; Romani, Maurizio; Distefano, Daniela; Bufi, Enida; Mule, Antonino; Magno, Stefano; Masetti, Riccardo; Bonomo, Lorenzo

    2010-01-01

    Introduction: Purpose of our study is to evaluate the role of the apparent diffusion coefficient (ADC) in the diagnosis of recurrent tumor on the scar in patients operated for breast cancer. Assess, therefore, the weight of diagnostic diffusion echo-planar sequence, in association with the morphological and dynamic sequences in the diagnosis of tumor recurrence versus surgical scar. Materials and methods: From September 2007 to March 2009, 72 patients operated for breast cancer with suspected recurrence on the scar were consecutively subjected to magnetic resonance imaging (MRI), including use of a diffusion sequence. All patients with pathological enhancement in the scar were then subjected to histological typing. MRI was considered negative in the absence of areas of suspicious enhancement. In all cases it was measured the ADC value in the scar area or in the area with pathological enhancement. The ADC values were compared with MRI findings and histological results obtained. Results: 26 cases were positive/doubtful at MRI and then subjected to histological typing: of these recurrences were 20 and benign were 6. 46 cases were judged negative at MRI and therefore not sent to cyto-histology. The average ADC value of recurrences was statistically lower of scarring (p < 0.001). Conclusions: ADC value can be a specific parameter in differential diagnosis between recurrence and scar. The diffusion sequence, in association with the morphological and dynamic sequences, can be considered a promising tool for the surgical indication in suspected recurrence of breast cancer.

  17. A novel readout concept for multianode photomultiplier tubes with pad matrix anode layout

    Energy Technology Data Exchange (ETDEWEB)

    Popov, Vladimir [Thomas Jefferson National Accelerator Facility, Newport News, VA 23606 (United States)]. E-mail: Popov@jlab.org; Majewski, Stan [Thomas Jefferson National Accelerator Facility, Newport News, VA 23606 (United States); Welch, Benjamin L. [Thomas Jefferson National Accelerator Facility, Newport News, VA 23606 (United States)

    2006-11-01

    We have developed a new analog readout concept for multianode photomultiplier tubes with a pad matrix anode layout. This new readout technique is the result of a modification of a technique previously developed at the Detector Group of Jefferson Lab (V. Popov, US patent No: 6,747,263 B1) [V. Popov, S. Majewski, A.G. Weisenberger, Readout Electronics for Multianode Photomultiplier Tubes with Pad Matrix Anode Layout, Thomas Jefferson National Accelerator Facility, IEEE 2003 Medical Imaging Conference Record, November 2003]. The new analog readout circuit provides the same analog conversion of matrix 2-D output into X and Y projective output with a significant reduction of analog outputs. The old readout network consists of resistors' matrix and current collecting amplifiers, and it provides decoupling of each anode output into two directions (one to X and one to Y coordinates), but a decoupling function that is carried out independent of photomultiplier tube gains nonuniformity. A newly developed readout network (US patent pending) also consists of resistors' matrix and current collecting amplifiers, but the new matrix includes an additional dumping resistor that provides an excess current from anode pad grounding. As a result, we subtract an extra current of high-gain pads in order to move the pads gain to an absolute minimum value for a given photomultiplier tube. This gain equalization procedure reduces image distortion related to gain nonuniformity. The new readout technique was used in several new radiation imaging detectors designed in the Detector Group of Jefferson Lab. It shows a visible readout uniformity and linearity improvement. The test results of an initial evaluation of this readout that is applied for data readout of four H8500 Hamamtsu PSPMT are presented.

  18. Irradiation tests of readout chain components of the ATLAS liquid argon calorimeters

    International Nuclear Information System (INIS)

    Leroy, C.; Cheplakov, A.; Golikov, V.; Golubykh, S.; Kukhtin, V.; Kulagin, E.; Lushchikov, V.; Minashkin, V.; Shalyugin, A.

    2000-01-01

    Various readout chain components of the ATLAS liquid argon calorimeters have been exposed to high neutron fluences and γ doses at the irradiation test facility of the IBR-2 reactor of JINR, Dubna. Results of the capacitance and impedance measurements of coaxial cables are presented. Results of peeling tests of PC board samples (carton and copper strips) as a measure of the bonding agent irradiation hardness are also reported

  19. Irradiation tests of readout chain components of the ATLAS liquid argon calorimeters

    CERN Document Server

    Leroy, C; Golikov, V; Golubyh, S M; Kukhtin, V; Kulagin, E; Luschikov, V; Minashkin, V F; Shalyugin, A N

    1999-01-01

    Various readout chain components of the ATLAS liquid argon calorimeters have been exposed to high neutron fluences and $gamma$-doses at the irradiation test facility of the IBR-2 reactor of JINR, Dubna. Results of the capacitance and impedance measurements of coaxial cables are presented. Results of peeling tests of PC board samples (kapton and copper strips) as a measure of the bonding agent irradiation hardness are also reported.

  20. The Philosophy and Feasibility of Dual Readout Calorimetry

    International Nuclear Information System (INIS)

    Hauptman, John

    2006-01-01

    I will discuss the general physical ideas behind dual-readout calorimetry, their implementation in DREAM (Dual REAdout Module) with exact separation of scintillation and Cerenkov light, implementation with mixed light in DREAM fibers, anticipated implementation in PbWO4 crystals with applications to the 4th Concept detector and to CMS, use in high energy gamma-ray and cosmic ray astrophysics with Cerenkov and N2 fluorescent light, and implementation in the 4th Concept detector for muon identification

  1. Prototype readout system for a multi Mpixels UV single-photon imaging detector capable of space flight operation

    Science.gov (United States)

    Seljak, A.; Cumming, H. S.; Varner, G.; Vallerga, J.; Raffanti, R.; Virta, V.

    2018-02-01

    Our collaboration works on the development of a large aperture, high resolution, UV single-photon imaging detector, funded through NASA's Strategic Astrophysics Technology (SAT) program. The detector uses a microchannel plate for charge multiplication, and orthogonal cross strip (XS) anodes for charge readout. Our target is to make an advancement in the technology readiness level (TRL), which enables real scale prototypes to be tested for future NASA missions. The baseline detector has an aperture of 50×50 mm and requires 160 low-noise charge-sensitive channels, in order to extrapolate the incoming photon position with a spatial resolution of about 20 μm FWHM. Technologies involving space flight require highly integrated electronic systems operating at very low power. We have designed two ASICs which enable the construction of such readout system. First, a charge sensitive amplifier (CSAv3) ASIC provides an equivalent noise charge (ENC) of around 600 e-, and a baseline gain of 10 mV/fC. The second, a Giga Sample per Second (GSPS) ASIC, called HalfGRAPH, is a 12-bit analog to digital converter. Its architecture is based on waveform sampling capacitor arrays and has about 8 μs of analog storage memory per channel. Both chips encapsulate 16 measurement channels. Using these chips, a small scale prototype readout system has been constructed on a FPGA Mezzanine Board (FMC), equipped with 32 measurement channels for system evaluation. We describe the construction of HalfGRAPH ASIC, detector's readout system concept and obtained results from the prototype system. As part of the space flight qualification, these chips were irradiated with a Cobalt gamma-ray source, to verify functional operation under ionizing radiation exposure.

  2. Frequency-domain readout multiplexing of transition-edge sensor arrays

    Energy Technology Data Exchange (ETDEWEB)

    Lanting, T.M. [Physics Department, University of California, Berkeley, CA 94720 (United States)]. E-mail: tlanting@berkeley.edu; Arnold, K. [Physics Department, University of California, Berkeley, CA 94720 (United States); Cho, Hsiao-Mei [Physics Department, University of California, Berkeley, CA 94720 (United States); Clarke, John [Physics Department, University of California, Berkeley, CA 94720 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Dobbs, Matt [Physics Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Holzapfel, William [Physics Department, University of California, Berkeley, CA 94720 (United States); Lee, Adrian T. [Physics Department, University of California, Berkeley, CA 94720 (United States); Physics Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Lueker, M. [Physics Department, University of California, Berkeley, CA 94720 (United States); Richards, P.L. [Physics Department, University of California, Berkeley, CA 94720 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Smith, A.D. [Northrop-Grumman, Redondo Beach, CA 94278 (United States); Spieler, H.G. [Physics Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2006-04-15

    We have demonstrated frequency-domain readout multiplexing of eight channels for superconducting transition-edge sensor bolometer arrays. The multiplexed readout noise is 6.5 pA/{radical}Hz, well below the bolometer dark noise of 15-20 pA/{radical}Hz. We measure an upper limit on crosstalk of 0.004 between channels adjacent in frequency which meets our design requirement of 0.01. We have observed vibration insensitivity in our frequency-domain multiplexed transition-edge sensors, making this system very attractive for telescope and satellite observations. We also discuss extensions to our multiplexed readout. In particular, we are developing a SQUID flux-locked loop that is entirely cold and collaborating on digital multiplexer technology in order to scale up the number of multiplexed channels.

  3. SU-F-303-13: Initial Evaluation of Four Dimensional Diffusion- Weighted MRI (4D-DWI) and Its Effect On Apparent Diffusion Coefficient (ADC) Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y [Duke University Medical Physics Program (United States); Yin, F; Czito, B; Bashir, M; Palta, M; Cai, J [Duke University Medical Center, Durham, NC (United States); Zhong, X; Dale, B [Siemens Healthcare, Durham, NC (United States)

    2015-06-15

    Purpose: Diffusion-weighted imaging(DWI) has been shown to have superior tumor-to-tissue contrast for cancer detection.This study aims at developing and evaluating a four dimensional DWI(4D-DWI) technique using retrospective sorting method for imaging respiratory motion for radiotherapy planning,and evaluate its effect on Apparent Diffusion Coefficient(ADC) measurement. Materials/Methods: Image acquisition was performed by repeatedly imaging a volume of interest using a multi-slice single-shot 2D-DWI sequence in the axial planes and cine MRI(served as reference) using FIESTA sequence.Each 2D-DWI image were acquired in xyz-diffusion-directions with a high b-value(b=500s/mm2).The respiratory motion was simultaneously recorded using bellows.Retrospective sorting was applied in each direction to reconstruct 4D-DWI.The technique was evaluated using a computer simulated 4D-digital human phantom(XCAT),a motion phantom and a healthy volunteer under an IRB-approved study.Motion trajectories of regions-of-interests(ROI) were extracted from 4D-DWI and compared with reference.The mean motion trajectory amplitude differences(D) between the two was calculated.To quantitatively analyze the motion artifacts,XCAT were controlled to simulate regular motion and the motions of 10 liver cancer patients.4D-DWI,free-breathing DWI(FB- DWI) were reconstructed.Tumor volume difference(VD) of each phase of 4D-DWI and FB-DWI from the input static tumor were calculated.Furthermore, ADC was measured for each phase of 4D-DWI and FB-DWI data,and mean tumor ADC values(M-ADC) were calculated.Mean M-ADC over all 4D-DWI phases was compared with M-ADC calculated from FB-DWI. Results: 4D-DWI of XCAT,the motion phantom and the healthy volunteer demonstrated the respiratory motion clearly.ROI D values were 1.9mm,1.7mm and 2.0mm,respectively.For motion artifacts analysis,XCAT 4D-DWI images show much less motion artifacts compare to FB-DWI.Mean VD for 4D-WDI and FB-DWI were 8.5±1.4% and 108±15

  4. A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems

    Directory of Open Access Journals (Sweden)

    Kyeonghwan Park

    2017-04-01

    Full Text Available This paper presents a reconfigurable multi-sensor interface and its readout integrated circuit (ROIC for display-based multi-sensor systems, which builds up multi-sensor functions by utilizing touch screen panels. In addition to inherent touch detection, physiological and environmental sensor interfaces are incorporated. The reconfigurable feature is effectively implemented by proposing two basis readout topologies of amplifier-based and oscillator-based circuits. For noise-immune design against various noises from inherent human-touch operations, an alternate-sampling error-correction scheme is proposed and integrated inside the ROIC, achieving a 12-bit resolution of successive approximation register (SAR of analog-to-digital conversion without additional calibrations. A ROIC prototype that includes the whole proposed functions and data converters was fabricated in a 0.18 μm complementary metal oxide semiconductor (CMOS process, and its feasibility was experimentally verified to support multiple heterogeneous sensing functions of touch, electrocardiogram, body impedance, and environmental sensors.

  5. Diffusion weighted MRI and 18F-FDG PET/CT in non-small cell lung cancer (NSCLC): Does the apparent diffusion coefficient (ADC) correlate with tracer uptake (SUV)?

    International Nuclear Information System (INIS)

    Regier, M.; Derlin, T.; Schwarz, D.; Laqmani, A.; Henes, F.O.; Groth, M.; Buhk, J.-H.; Kooijman, H.; Adam, G.

    2012-01-01

    Introduction: To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). Materials and methods: 18F-FDG PET/CT and DWI (TR/TE, 2000/66 ms; b-values, 0 and 500 s/mm 2 ) were performed in 41 consecutive patients with histologically verified NSCLC. Analysing the PET-CT data calculation of the mean (SUV mean ) and maximum (SUV max ) SUV was performed. By placing a region-of-interest (ROI) encovering the entire tumor mean (ADC mean ) and minimum ADC (ADC min ) were determined by two independent radiologists. Results of 18F-FDG PET-CT and DWI were compared on a per-patient basis. For statistical analysis Pearson's correlation coefficient, Bland–Altman and regression analysis were assessed. Results: Data analysis revealed a significant inverse correlation of the ADC min and SUV max (r = −0.46; p = 0.032). Testing the correlation of the ADC min and SUV max for each histological subtype separately revealed that the inverse correlation was good for both adenocarcinomas (r = −0.47; p = 0.03) and squamouscell carcinomas (r = −0.71; p = 0.002), respectively. No significant correlation was found for the comparison of ADC min and SUV mean (r = −0.29; p = 0.27), ADC mean vs. SUV mean (r = −0.28; p = 0.31) or ADC mean vs. SUV max (r = −0.33; p = 0.23). The κ-value of 0.88 indicated a good agreement between both observers. Conclusion: This preliminary study is the first to verify the relation between the SUV and the ADC in NSCLC. The significant inverse correlation of these two quantitative imaging approaches points out the association of metabolic activity and tumor cellularity. Therefore, DWI with ADC measurement might represent a new prognostic marker in NSCLC

  6. DOSIMO - an interactive web service of the GSF Readout Center

    International Nuclear Information System (INIS)

    Huebner, S.; Lempart, R.

    2002-01-01

    Under the Radiation Protection and X-ray Ordinances, official personnel dosimetry centers are charged with measuring, documenting, and monitoring personnel doses as independent agencies. The GSF Readout Center (AWST) for Personnel Dosimeters and Area Monitors is responsible for monitoring persons occupationally exposed to radiation in the federal states of Baden-Wuerttemberg, Bavaria, Hesse, and Schleswig-Holstein. The largest German readout center uses new media in personnel dosimetry in order to simplify and speed up data transfer. In October 1998, AWST in cooperation with ADANAT ENTIRE SYSTEMS implemented an Internet interface. As a result, AWST is the first European readout center to offer not only a possibility to disseminate information through the Internet by means of the DOSIMO (DOSIMETRY On-line) Internet Service, but also enabling the interactive data exchange by electronic means with authorized customers. DOSIMO users enjoy the decisive advantage of having the results of readout of their dosimeters ready for use as soon as they have become available. (orig.) [de

  7. Optical readout in a multi-module system test for the ATLAS pixel detector

    International Nuclear Information System (INIS)

    Flick, Tobias; Becks, Karl-Heinz; Gerlach, Peter; Kersten, Susanne; Maettig, Peter; Nderitu Kirichu, Simon; Reeves, Kendall; Richter, Jennifer; Schultes, Joachim

    2006-01-01

    The innermost part of the ATLAS experiment at the LHC, CERN, will be a pixel detector, which is presently under construction. The command messages and the readout data of the detector are transmitted over an optical data path. The readout chain consists of many components which are produced at several locations around the world, and must work together in the pixel detector. To verify that these parts are working together as expected a system test has been built up. It consists of detector modules, optoboards, optical fibres, Back of Crate cards, Readout Drivers, and control computers. In this paper, the system test setup and the operation of the readout chain are described. Also, some results of tests using the final pixel detector readout chain are given

  8. [Characteristics of high resolution diffusion weighted imaging apparent diffusion coefficient histogram and its correlations with cancer stages in patients with nasopharyngeal carcinoma].

    Science.gov (United States)

    Wang, G J; Wang, Y; Ye, Y; Chen, F; Lu, Y T; Li, S L

    2017-11-07

    Objective: To investigate the features of apparent diffusion coefficient (ADC) histogram parameters based on entire tumor volume data in high resolution diffusion weighted imaging of nasopharyngeal carcinoma (NPC) and to evaluate its correlations with cancer stages. Methods: This retrospective study included 154 cases of NPC patients[102 males and 52 females, mean age (48±11) years]who had received readout segmentation of long variable echo trains of MRI scan before radiation therapy. The area of tumor was delineated on each section of axial ADC maps to generate ADC histogram by using Image J. ADC histogram of entire tumor along with the histogram parameters-the tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness and kurtosis were obtained by merging all sections with SPSS 22.0 software. Intra-observer repeatability was assessed by using intra-class correlation coefficients (ICC). The patients were subdivided into two groups according to cancer volume: small cancer group (histogram parameters and cancer stages was evaluated with Spearman test. Results: The ICC of measuring ADC histogram parameters of tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness, kurtosis was 0.938, 0.861, 0.885, 0.838, 0.836, 0.358 and 0.456, respectively. The tumor voxels was positively correlated with T staging ( r =0.368, P histogram (ADC(mean), ADC(25%), ADC(50%)) increases with T staging in NPC smaller than 2 cm(3).

  9. Design and performance of the new cathode readout proportional chambers in LASS

    International Nuclear Information System (INIS)

    Aiken, G.; Aston, D.; Dunwoodie, W.

    1980-10-01

    The design and construction of a new proportional chamber system for the LASS spectrometer are discussed. This system consists of planar and cylindrical chambers employing anode wire and cathode strip readout techniques. The good timing characteristics of anode readout combine with the excellent spatial resolution of cathode readout to provide powerful and compact detectors. Preliminary resolution data are presented along with operating characteristics of the various devices

  10. Dual-readout Immunochromatographic Assay by Utilizing MnO2 Nanoflowers as the Unique Colorimetric/Chemiluminescent Probe

    Energy Technology Data Exchange (ETDEWEB)

    Ouyang, Hui; Lu, Quian; Wang, Wenwen; Song, Yang; Tu, Xinman; Zhu, Chengzhou; Smith, Jordan N.; Du, Dan; Fu, Zhifeng; Lin, Yuehe

    2018-04-17

    Manganese dioxide nanoflowers (MnO2 NFs) were synthesized and utilized as a dual readout probe to develop a novel immunochromatographic test strip (ITS) for detecting pesticide residues using chlorpyrifos as the model analyte. MnO2 NFs-labeled antibody for chlorpyrifos was employed as the signal tracer for conducting the ITS. After 10-min competitive immunoreaction, the tracer antibody was captured by the immobilized immunogen on test line in the test strip, resulting in the accumulation of MnO2 NFs. The accumulation of MnO2 NFs led to the appearance of brown color on the test line, which could be easily observed by the naked eye as a qualitative readout. Moreover, MnO2 NFs showed a remarkably enhancing effect on the luminol-H2O2 chemiluminescent (CL) system. Unlike peroxidase-like nanomaterials, the enhancing mechanism of MnO2 NFs was based on its oxidant activity to decompose H2O2 for forming reactive oxygen species. After initiating the CL system in the test zone, strong CL signal was collected as a quantitative readout to sensitively detect chlorpyrifos. Under optimal conditions, the linear range of chlorpyrifos was 0.1–50 ng/mL with a low detection limit of 0.033 ng/mL (S/N = 3). The reliability of the dual-readout ITS was successfully demonstrated by the application on traditional Chinese medicine and environmental water samples. Due to the simultaneous rapid-qualitative and sensitive-quantitative detection, the dual-readout protocol provides a promising strategy for rapid screening and field assay on various areas such as environmental monitoring, food safety and point-of-care testing.

  11. A Novel Front-End ASIC With Post Digital Filtering and Calibration for CZT-Based PET Detector

    International Nuclear Information System (INIS)

    Gao, W.; Yin, J.; Li, C.; Zeng, H.; Gao, D.; Hu, Y.

    2015-01-01

    This paper presents a novel front-end electronics based on a front-end ASIC with post digital filtering and calibration dedicated to CZT detectors for PET imaging. A cascade amplifier based on split-leg topology is selected to realize the charge-sensitive amplifier (CSA) for the sake of low noise performances and the simple scheme of the power supplies. The output of the CSA is connected to a variable-gain amplifier to generate the compatible signals for the A/D conversion. A multi-channel single-slope ADC is designed to sample multiple points for the digital filtering and shaping. The digital signal processing algorithms are implemented by a FPGA. To verify the proposed scheme, a front-end readout prototype ASIC is designed and implemented in 0.35 μm CMOS process. In a single readout channel, a CSA, a VGA, a 10-bit ADC and registers are integrated. Two dummy channels, bias circuits, and time controller are also integrated. The die size is 2.0 mm x 2.1 mm. The input range of the ASIC is from 2000 e - to 100000 e - , which is suitable for the detection of the X-and gamma ray from 11.2 keV to 550 keV. The linearity of the output voltage is less than 1 %. The gain of the readout channel is 40.2 V/pC. The static power dissipation is about 10 mW/channel. The above tested results show that the electrical performances of the ASIC can well satisfy PET imaging applications. (authors)

  12. A Novel Front-End ASIC With Post Digital Filtering and Calibration for CZT-Based PET Detector

    Energy Technology Data Exchange (ETDEWEB)

    Gao, W.; Yin, J.; Li, C.; Zeng, H.; Gao, D. [Institute of Microelectronics, School of Computer Science and Techonology, Northwestern Polytechnical University, Xi' an (China); Hu, Y. [Institut Pluridiscipline Hubert Curien, CNRS/UDS/IN2P3, Strasbourg (France)

    2015-07-01

    This paper presents a novel front-end electronics based on a front-end ASIC with post digital filtering and calibration dedicated to CZT detectors for PET imaging. A cascade amplifier based on split-leg topology is selected to realize the charge-sensitive amplifier (CSA) for the sake of low noise performances and the simple scheme of the power supplies. The output of the CSA is connected to a variable-gain amplifier to generate the compatible signals for the A/D conversion. A multi-channel single-slope ADC is designed to sample multiple points for the digital filtering and shaping. The digital signal processing algorithms are implemented by a FPGA. To verify the proposed scheme, a front-end readout prototype ASIC is designed and implemented in 0.35 μm CMOS process. In a single readout channel, a CSA, a VGA, a 10-bit ADC and registers are integrated. Two dummy channels, bias circuits, and time controller are also integrated. The die size is 2.0 mm x 2.1 mm. The input range of the ASIC is from 2000 e{sup -} to 100000 e{sup -}, which is suitable for the detection of the X-and gamma ray from 11.2 keV to 550 keV. The linearity of the output voltage is less than 1 %. The gain of the readout channel is 40.2 V/pC. The static power dissipation is about 10 mW/channel. The above tested results show that the electrical performances of the ASIC can well satisfy PET imaging applications. (authors)

  13. Prometeo: A portable test-bench for the upgraded front-end electronics of the ATLAS Tile calorimeter

    CERN Document Server

    Bullock, D; The ATLAS collaboration; Hofsajer, I; Govender, M; Mellado, B; Moreno, P; Reed, R; Ruan, X; Sandrock, C; Solans, C; Suter, R; Usai, G; Valero, A

    2014-01-01

    Prometeo is the portable test-bench for the full certification of the front-end electronics of the ATLAS Tile calorimeter designed for the upgrade phase-II. It is a high throughput electronics system designed to simultaneously read-out all the samples from 12 channels at the LHC bunch crossing frequency and assess the quality of the data in real-time. The core of the system is a Xilinx Virtex 7 evaluation board extended with a dual QSFP FMC module to read-out and control the front-end boards. The rest of the functionalities of the system are provided by a HV mezzanine board that to turn on the gain of the photo-multipliers, an LED board that sends light to illuminate them, and a 12 channel ADC board that samples the analog output of the front-end. The system is connected by ethernet to a GUI client from which QA tests are performed on the electronics such as noise measurements and linearity response to an injected charge.

  14. Machine Learning Method Applied in Readout System of Superheated Droplet Detector

    Science.gov (United States)

    Liu, Yi; Sullivan, Clair Julia; d'Errico, Francesco

    2017-07-01

    Direct readability is one advantage of superheated droplet detectors in neutron dosimetry. Utilizing such a distinct characteristic, an imaging readout system analyzes image of the detector for neutron dose readout. To improve the accuracy and precision of algorithms in the imaging readout system, machine learning algorithms were developed. Deep learning neural network and support vector machine algorithms are applied and compared with generally used Hough transform and curvature analysis methods. The machine learning methods showed a much higher accuracy and better precision in recognizing circular gas bubbles.

  15. A continuous-time sigma delta ADC with increased immunity to wide-band interferers

    NARCIS (Netherlands)

    Philips, K.J.P.; Nuijten, P.A.C.M.; Roovers, R.L.J.; Roermund, van A.H.M.; Munoz Chavero, F.; Tejero Pallarés, M.; Torralba, A.

    2004-01-01

    Receivers are being digitized in a quest for flexibility. Analog filters and programmable gain stages are being exchanged for digital processing at the price of a very challenging ADC. This paper presents an alternative solution where the filter and programmable gain functionality is integrated into

  16. Readout Electronics Upgrades of the ATLAS Liquid Argon Calorimeter

    CERN Document Server

    Anelli, Christopher Ryan; The ATLAS collaboration

    2018-01-01

    The high-luminosity LHC will provide 5-7 times higher luminosites than the orignal design. An improved readout system of the ATLAS Liquid Argon Calorimeter is needed to readout the 182,500 calorimeter cells at 40 MHz with 16 bit dynamic range in these conditions. Low-noise, low-power, radiation-tolerant and high-bandwidth electronics components are being developed in 65 and 130 nm CMOS technologies. First prototypes of the front-end electronics components show good promise to match the stringent specifications. The off-detector electronics will make use of FPGAs connected through high-speed links to perform energy reconstruction, data reduction and buffering. Results of tests of the first prototypes of front-end components will be presented, along with design studies on the performance of the off-detector readout system.

  17. CASAGEM: a readout ASIC for micro pattern gas detectors

    International Nuclear Information System (INIS)

    He Li; Deng Zhi; Liu Yinong

    2012-01-01

    A readout ASIC for micro pattern gas detectors has been designed This ASIC integrates 16 channels for anode readout and 1 channel for cathode readout which can make use of the signal of detector's cathode to generate a trigger Every channel can provide amplification and shaping of detector signals. The ASIC can also provide adjustable gain which can be adjusted from 2 mV/fC to 40 mV/fC, and adjustable shaping time which can be adjusted from 20 ns to 80 ns; so this ASIC can be applied to detectors with wide range output signal and different counting rate. The ASIC is fabricated with Chartered 0.35 μm CMOS process More circuit design Details and test results will be presented. (authors)

  18. Readout for a large area neutron sensitive microchannel plate detector

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yiming [Department of Engineering Physics, Tsinghua University, Beijing (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); Yang, Yigang, E-mail: yangyigang@mail.tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); Wang, Xuewu; Li, Yuanjing [Department of Engineering Physics, Tsinghua University, Beijing (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China)

    2015-06-01

    A neutron sensitive microchannel plate (MCP) detector was developed for neutron imaging on the beamline of a compact pulsed hadron source (CPHS). The detector was set up with a Wedge-and-Strip Anode (WSA) and a delay line anode readout to compare the spatial resolution and throughput with these two anodes. Tests show that the WSA readout is suitable for small area imaging with a spatial resolution of 200 μm with low energy X-rays in a 50 mm diameter MCP–WSA assembly. However, the spatial resolution deteriorated to ~2 mm in a 106 mm diameter MCP–WSA assembly because the noise caused by the parasitic capacitance is 10 times larger in the larger assembly than in the 50 mm diameter assembly. A 120 mm by 120 mm delay line anode was then used for the 106 mm MCP readout. The spatial resolution was evaluated for various voltages applied to the MCP V-stack, various readout voltages and various distances between the MCP V-stack rear face and the delay line. The delay line readout had resolutions of 65.6 μm in the x direction and 63.7 μm in the y direction and the throughput was greater than 600 kcps. The MCP was then used to acquire a neutron image of an USAF1951 Gd-mask.

  19. Study and optimization of the spatial resolution for detectors with binary readout

    Energy Technology Data Exchange (ETDEWEB)

    Yonamine, R., E-mail: ryo.yonamine@ulb.ac.be; Maerschalk, T.; Lentdecker, G. De

    2016-09-11

    Using simulations and analytical approaches, we have studied single hit resolutions obtained with a binary readout, which is often proposed for high granularity detectors to reduce the generated data volume. Our simulations considering several parameters (e.g. strip pitch) show that the detector geometry and an electronics parameter of the binary readout chips could be optimized for binary readout to offer an equivalent spatial resolution to the one with an analog readout. To understand the behavior as a function of simulation parameters, we developed analytical models that reproduce simulation results with a few parameters. The models can be used to optimize detector designs and operation conditions with regard to the spatial resolution.

  20. Integrated microelectronic capacitive readout subsystem for lab-on-a-chip applications

    International Nuclear Information System (INIS)

    Spathis, Christos; Georgakopoulou, Konstantina; Petrellis, Nikos; Efstathiou, Konstantinos; Birbas, Alexios

    2014-01-01

    A mixed-signal capacitive biosensor readout system is presented with its main readout functionality embedded in an integrated circuit, compatible with complementary metal oxide semiconductor-type biosensors. The system modularity allows its usage as a consumable since it eventually leads to a system-on-chip where sensor and readout circuitry are hosted on the same die. In this work, a constant current source is used for measuring the input capacitance. Compared to most capacitive biosensor readout circuits, this method offers the convenience of adjusting both the range and the resolution, depending on the requirements dictated by the application. The chip consumes less than 5 mW of power and the die area is 0.06 mm 2 . It shows a broad input capacitance range (capable of measuring bio-capacitances from 6 pF to 9.8 nF), configurable resolution (down to 1 fF), robustness to various biological experiments and good linearity. The integrated nature of the readout system is proven to be sufficient both for one-time in situ (consumable-type) bio-measurements and its incorporation into a point-of-care system. (paper)

  1. First Tests of a New Fast Waveform Digitizer for PMT Signal Read-out from Liquid Argon Dark Matter Detectors

    Science.gov (United States)

    Szelc, A. M.; Canci, N.; Cavanna, F.; Cortopassi, A.; D'Incecco, M.; Mini, G.; Pietropaolo, F.; Romboli, A.; Segreto, E.; Acciarri, R.

    A new generation Waveform Digitizer board as been recently made available on the market by CAEN. The new board CAEN V1751 with 8 Channels per board, 10 bit, 1 GS/s Flash ADC Waveform Digitizer (or 4 channel, 10 bit, 2 GS/s Flash ADC Waveform Digitizer -Dual Edge Sampling mode) with threshold and Auto-Trigger capabilities provides an ideal (relatively low-cost) solution for reading signals from liquid Argon detectors for Dark Matter search equipped with an array of PMTs for the detection of scintillation light. The board was extensively used in real experimental conditions to test its usefulness for possible future uses and to compare it with a state of the art digital oscilloscope. As results, PMT Signal sampling at 1 or 2 GS/s is appropriate for the reconstruction of the fast component of the signal scintillation in Argon (characteristic time of about 4 ns) and the extended dynamic range, after a small customization, allows for the detection of signals in the range of energy needed. The bandwidth is found to be adequate and the intrinsic noise is very low.

  2. Normal hepatic parenchyma visibility and ADC quantification on diffusion-weighted MRI at 3 T: influence of age, gender, and iron content

    Energy Technology Data Exchange (ETDEWEB)

    Metens, Thierry [MRI Clinics, Department of Radiology, Hopital Erasme, Bruxelles (Belgium); Universite Libre de Bruxelles, Magnetic Resonance Imaging Clinics, Department of Radiology, Hopital Erasme, Bruxelles (Belgium); Ferraresi, Kellen Fanstone; Farchione, Alessandra; Bali, Maria Antonietta; Matos, Celso [MRI Clinics, Department of Radiology, Hopital Erasme, Bruxelles (Belgium); Moreno, Christophe [Universite Libre de Bruxelles, Department of Gastroenterology, Hepatopancreatology, and Digestive Oncology, Hopital Erasme, Bruxelles (Belgium)

    2014-12-15

    To investigate how normal liver parenchyma visibility on 3 T diffusion-weighted images (DWI) and apparent diffusion coefficient (ADC) quantification are influenced by age, gender, and iron content. Between February 2011 and April 2013, 86 patients (52 women) with normal livers who underwent respiratory-triggered abdominal 3 T DWI (b = 0, 150, 600, 1,000 s/mm{sup 2}) were retrospectively included. Normal liver and spleen parenchyma visibility was scored independently by two readers. Correlations between visibility scores or ADC with age, gender, T2*, or recent serum ferritin (SF) were investigated. Liver visibility scores in b = 1,000 s/mm{sup 2} images correlated with the age (Spearman R = -0.56 in women, -0.45 in men), T2* (R = 0.75) and SF (R = -0.64) and were significantly higher in women (P < 0.01). SF and T2* were within normal values (T2*: 13 - 31 ms, SF: 14 - 230 μg/L). Liver ADC correlated with visibility scores (R = 0.69) and T2* (R = 0.64) and was age- and gender-dependent. ADC ROI standard deviation negatively correlated with visibility scores (R = -0.65) and T2* (R = -0.62). The spleen visibility did not depend on age or gender. Normal liver parenchyma visibility in DWI is age- and gender-dependent, according to the iron content. Visibility scores and iron content significantly affect ADC quantification in the normal liver. (orig.)

  3. Normal hepatic parenchyma visibility and ADC quantification on diffusion-weighted MRI at 3 T: influence of age, gender, and iron content

    International Nuclear Information System (INIS)

    Metens, Thierry; Ferraresi, Kellen Fanstone; Farchione, Alessandra; Bali, Maria Antonietta; Matos, Celso; Moreno, Christophe

    2014-01-01

    To investigate how normal liver parenchyma visibility on 3 T diffusion-weighted images (DWI) and apparent diffusion coefficient (ADC) quantification are influenced by age, gender, and iron content. Between February 2011 and April 2013, 86 patients (52 women) with normal livers who underwent respiratory-triggered abdominal 3 T DWI (b = 0, 150, 600, 1,000 s/mm 2 ) were retrospectively included. Normal liver and spleen parenchyma visibility was scored independently by two readers. Correlations between visibility scores or ADC with age, gender, T2*, or recent serum ferritin (SF) were investigated. Liver visibility scores in b = 1,000 s/mm 2 images correlated with the age (Spearman R = -0.56 in women, -0.45 in men), T2* (R = 0.75) and SF (R = -0.64) and were significantly higher in women (P < 0.01). SF and T2* were within normal values (T2*: 13 - 31 ms, SF: 14 - 230 μg/L). Liver ADC correlated with visibility scores (R = 0.69) and T2* (R = 0.64) and was age- and gender-dependent. ADC ROI standard deviation negatively correlated with visibility scores (R = -0.65) and T2* (R = -0.62). The spleen visibility did not depend on age or gender. Normal liver parenchyma visibility in DWI is age- and gender-dependent, according to the iron content. Visibility scores and iron content significantly affect ADC quantification in the normal liver. (orig.)

  4. A new PCI card for readout in high energy physics experiments

    CERN Document Server

    Floris, M; Marras, D; Usai, G L; David, A

    2004-01-01

    Recently some high energy physics experiments started to adopt readout systems based on the PCI architecture. In this context a new PCI card that can be adapted to several readout schemes has been designed. The card contains a large 64 MB local buffer, programmable FPGA logic and a PLX PCI bridge. The solution to use a PCI bridge external to the programmable logic allows to greatly simplify projects at the level of the on-board local bus. The card is presently used as the basic readout unit of the NA60 experiment. In this context, coupling it to different mezzanine cards it is possible to create interfaces to VME/CAMAC modules or to custom front-end electronics as for the case of the silicon vertex detector. Moreover, it is used as a readout test system for the ALICE muon chambers. (10 refs).

  5. Preliminary Assessment of Microwave Readout Multiplexing Factor

    Energy Technology Data Exchange (ETDEWEB)

    Croce, Mark Philip [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Koehler, Katrina Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rabin, Michael W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bennett, D. A. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States); Mates, J. A. B. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States); Gard, J. D. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States); Becker, D. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States); Schmidt, D. R. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States); Ullom, J. N. [National Inst. of Standards and Technology (NIST), Boulder, CO (United States)

    2017-01-23

    Ultra-high resolution microcalorimeter gamma spectroscopy is a new non-destructive assay technology for measurement of plutonium isotopic composition, with the potential to reduce total measurement uncertainty to a level competitive with destructive analysis methods [1-4]. Achieving this level of performance in practical applications requires not only the energy resolution now routinely achieved with transition-edge sensor microcalorimeter arrays (an order of magnitude better than for germanium detectors) but also high throughput. Microcalorimeter gamma spectrometers have not yet achieved detection efficiency and count rate capability that is comparable to germanium detectors, largely because of limits from existing readout technology. Microcalorimeter detectors must be operated at low temperature to achieve their exceptional energy resolution. Although the typical 100 mK operating temperatures can be achieved with reliable, cryogen-free systems, the cryogenic complexity and heat load from individual readout channels for large sensor arrays is prohibitive. Multiplexing is required for practical systems. The most mature multiplexing technology at present is time-division multiplexing (TDM) [3, 5-6]. In TDM, the sensor outputs are switched by applying bias current to one SQUID amplifier at a time. Transition-edge sensor (TES) microcalorimeter arrays as large as 256 pixels have been developed for X-ray and gamma-ray spectroscopy using TDM technology. Due to bandwidth limits and noise scaling, TDM is limited to a maximum multiplexing factor of approximately 32-40 sensors on one readout line [8]. Increasing the size of microcalorimeter arrays above the kilopixel scale, required to match the throughput of germanium detectors, requires the development of a new readout technology with a much higher multiplexing factor.

  6. Central FPGA-based Destination and Load Control in the LHCb MHz Event Readout

    CERN Document Server

    Jacobsson, Richard

    2012-01-01

    The readout strategy of the LHCb experiment [1] is based on complete event readout at 1 MHz [2]. Over 300 sub-detector readout boards transmit event fragments at 1 MHz over a commercial 70 Gigabyte/s switching network to a distributed event building and trigger processing farm with 1470 individual multi-core computer nodes [3]. In the original specifications, the readout was based on a pure push protocol. This paper describes the proposal, implementation, and experience of a powerful non-conventional mixture of a push and a pull protocol, akin to credit-based flow control. A high-speed FPGA-based central master module controls the event fragment packing in the readout boards, the assignment of the farm node destination for each event, and controls the farm load based on an asynchronous pull mechanism from each farm node. This dynamic readout scheme relies on generic event requests and the concept of node credit allowing load balancing and trigger rate regulation as a function of the global farm load. It also ...

  7. Photonic-assisted time-interleaved ADC based on optical delay line

    International Nuclear Information System (INIS)

    Xu, Chen; Zheng, Shilie; Chen, Xinyi; Chi, Hao; Jin, Xiaofeng; Zhang, Xianmin

    2016-01-01

    An approach to implement photonic-assisted time-interleaved analog-to-digital conversion and its calibration method are presented. The analog modulated optical signal is divided into M channels, suffering different time delay induced by optical delay lines which provide great flexibility in producing time intervals and is then sampled by electronic analog-to-digital converters (ADCs). The channel mismatches resulting in performance degradation are estimated by a modified sine wave fitting method. The time mismatch and other mismatches are corrected by fine optical delay adjustment and digital processing, respectively. A four-channel photonic-assisted time-interleaved analog-to-digital converter (TIADC) system operating at 40 GSa s −1 was demonstrated experimentally. The photonic-assisted TIADC system was tested with a 6.31 GHz sine wave signal, exhibiting 40.3 dB signal-to-noise and distortion ratio (SINAD) and 57.6 dBc spurious-free dynamic range (SFDR). It is shown that the SINAD is dominated by the signal-to-noise ratio (SNR) of the analog optical link and the SFDR of the proposed system is limited by the linearity of the link. (paper)

  8. Impact of the 'non-destructive' multiple-readout on the Lorentzian noise

    International Nuclear Information System (INIS)

    Guazzoni, C.; Gatti, E.; Geraci, A.

    2006-01-01

    In this paper, we discuss the effect of 'non-destructive' multiple-readout on the Lorentzian noise. To our knowledge, it is the first time that such interaction is investigated. We have studied the peculiarities of the shape of the optimum weighting function for the multiple-readout technique in the presence of Lorentzian noise and other noise sources. The impact of the Lorentzian noise on the resolution achievable with the multiple-readout technique is analyzed in detail with respect to the interaction between the oscillation time and the characteristic time constant of the Lorentzian noise

  9. Note: Readout of a micromechanical magnetometer for the ITER fusion reactor

    International Nuclear Information System (INIS)

    Rimminen, H.; Kyynäräinen, J.

    2013-01-01

    We present readout instrumentation for a MEMS magnetometer, placed 30 m away from the MEMS element. This is particularly useful when sensing is performed in high-radiation environment, where the semiconductors in the readout cannot survive. High bandwidth transimpedance amplifiers are used to cancel the cable capacitances of several nanofarads. A frequency doubling readout scheme is used for crosstalk elimination. Signal-to-noise ratio in the range of 60 dB was achieved and with sub-percent nonlinearity. The presented instrument is intended for the steady-state magnetic field measurements in the ITER fusion reactor.

  10. The 8 bits 100 MS/s Pipeline ADC for the INNOTEP Project – TWEPP-09

    CERN Document Server

    Crampon, S; Chanal, H; Lecoq, J; Mathez, H; Vert, P E

    2009-01-01

    This paper describes the Analog to Digital Converter developed for the front end electronic of the IN2P3 INNOTEP project by the “pole microelectronique Rhone-Auvergne”. (Collaboration between LPC Clermont-Ferrand and IPNL Lyon). This ADC is a 4 stages 2.5 bits per stage pipe line with open loops track and holds and amplifiers. It runs at 100MSamples/s and has 8 bits resolution. The stages used two lines, the gain line and the comparison line, with most operators running in current. The main idea of this current line is to make a first step toward an all in current structure. Currently, this ADC is designed with a 0,35μm SiGe technology.

  11. DNA Nanobiosensors: An Outlook on Signal Readout Strategies

    Directory of Open Access Journals (Sweden)

    Arun Richard Chandrasekaran

    2017-01-01

    Full Text Available A suite of functionalities and structural versatility makes DNA an apt material for biosensing applications. DNA-based biosensors are cost-effective and sensitive and have the potential to be used as point-of-care diagnostic tools. Along with robustness and biocompatibility, these sensors also provide multiple readout strategies. Depending on the functionality of DNA-based biosensors, a variety of output strategies have been reported: fluorescence- and FRET-based readout, nanoparticle-based colorimetry, spectroscopy-based techniques, electrochemical signaling, gel electrophoresis, and atomic force microscopy.

  12. Utility of whole-lesion ADC histogram metrics for assessing the malignant potential of pancreatic intraductal papillary mucinous neoplasms (IPMNs).

    Science.gov (United States)

    Hoffman, David H; Ream, Justin M; Hajdu, Christina H; Rosenkrantz, Andrew B

    2017-04-01

    To evaluate whole-lesion ADC histogram metrics for assessing the malignant potential of pancreatic intraductal papillary mucinous neoplasms (IPMNs), including in comparison with conventional MRI features. Eighteen branch-duct IPMNs underwent MRI with DWI prior to resection (n = 16) or FNA (n = 2). A blinded radiologist placed 3D volumes-of-interest on the entire IPMN on the ADC map, from which whole-lesion histogram metrics were generated. The reader also assessed IPMN size, mural nodularity, and adjacent main-duct dilation. Benign (low-to-intermediate grade dysplasia; n = 10) and malignant (high-grade dysplasia or invasive adenocarcinoma; n = 8) IPMNs were compared. Whole-lesion ADC histogram metrics demonstrating significant differences between benign and malignant IPMNs were: entropy (5.1 ± 0.2 vs. 5.4 ± 0.2; p = 0.01, AUC = 86%); mean of the bottom 10th percentile (2.2 ± 0.4 vs. 1.6 ± 0.7; p = 0.03; AUC = 81%); and mean of the 10-25th percentile (2.8 ± 0.4 vs. 2.3 ± 0.6; p = 0.04; AUC = 79%). The overall mean ADC, skewness, and kurtosis were not significantly different between groups (p ≥ 0.06; AUC = 50-78%). For entropy (highest performing histogram metric), an optimal threshold of >5.3 achieved a sensitivity of 100%, a specificity of 70%, and an accuracy of 83% for predicting malignancy. No significant difference (p = 0.18-0.64) was observed between benign and malignant IPMNs for cyst size ≥3 cm, adjacent main-duct dilatation, or mural nodule. At multivariable analysis of entropy in combination with all other ADC histogram and conventional MRI features, entropy was the only significant independent predictor of malignancy (p = 0.004). Although requiring larger studies, ADC entropy obtained from 3D whole-lesion histogram analysis may serve as a biomarker for identifying the malignant potential of IPMNs, independent of conventional MRI features.

  13. Data readout system utilizing photonic integrated circuit

    Energy Technology Data Exchange (ETDEWEB)

    Stopiński, S., E-mail: S.Stopinski@tue.nl [COBRA Research Institute, Eindhoven University of Technology (Netherlands); Institute of Microelectronics and Optoelectronics, Warsaw University of Technology (Poland); Malinowski, M.; Piramidowicz, R. [Institute of Microelectronics and Optoelectronics, Warsaw University of Technology (Poland); Smit, M.K.; Leijtens, X.J.M. [COBRA Research Institute, Eindhoven University of Technology (Netherlands)

    2013-10-11

    We describe a novel optical solution for data readout systems. The core of the system is an Indium-Phosphide photonic integrated circuit performing as a front-end readout unit. It functions as an optical serializer in which the serialization of the input signal is provided by means of on-chip optical delay lines. The circuit employs electro-optic phase shifters to build amplitude modulators, power splitters for signal distribution, semiconductor optical amplifiers for signal amplification as well as on-chip reflectors. We present the concept of the system, the design and first characterization results of the devices that were fabricated in a multi-project wafer run.

  14. ADC multi-site test based on a pre-test with digital input stimulus

    NARCIS (Netherlands)

    Sheng, Xiaoqin; Metra, C.; Kerkhoff, Hans G.; Zjajo, Amir; Gronthoud, Guido

    2012-01-01

    This paper describes two novel algorithms based on the time-modulo reconstruction method intended for detection of the parametric faults in analogue-to-digital converters (ADC). In both algorithms, a pulse signal, in its slightly adapted form to allow sufficient time for converter settling, is taken

  15. ADC as a useful diagnostic tool for differentiating benign and malignant vertebral bone marrow lesions and compression fractures: a systematic review and meta-analysis.

    Science.gov (United States)

    Suh, Chong Hyun; Yun, Seong Jong; Jin, Wook; Lee, Sun Hwa; Park, So Young; Ryu, Chang-Woo

    2018-07-01

    To assess the sensitivity and specificity of quantitative assessment of the apparent diffusion coefficient (ADC) for differentiating benign and malignant vertebral bone marrow lesions (BMLs) and compression fractures (CFs) METHODS: An electronic literature search of MEDLINE and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver operating characteristic modelling were performed to evaluate the diagnostic performance of ADC for differentiating vertebral BMLs. Subgroup analysis was performed for differentiating benign and malignant vertebral CFs. Meta-regression analyses according to subject, study and diffusion-weighted imaging (DWI) characteristics were performed. Twelve eligible studies (748 lesions, 661 patients) were included. The ADC exhibited a pooled sensitivity of 0.89 (95% confidence interval [CI] 0.80-0.94) and a pooled specificity of 0.87 (95% CI 0.78-0.93) for differentiating benign and malignant vertebral BMLs. In addition, the pooled sensitivity and specificity for differentiating benign and malignant CFs were 0.92 (95% CI 0.82-0.97) and 0.91 (95% CI 0.87-0.94), respectively. In the meta-regression analysis, the DWI slice thickness was a significant factor affecting heterogeneity (p benign and malignant vertebral BMLs and CFs. • Quantitative assessment of ADC is useful in differentiating vertebral BMLs. • Quantitative ADC assessment for BMLs had sensitivity of 89%, specificity of 87%. • Quantitative ADC assessment for CFs had sensitivity of 92%, specificity of 91%. • The specificity is highest (95%) with thinner (< 5 mm) DWI slice thickness.

  16. Study of preamplifier, shaper and peak detector in readout ASIC for particle detector

    International Nuclear Information System (INIS)

    Wang Ke; Zhang Shengjun; Fan Lei; Li Xian

    2014-01-01

    Recently, kinds of particle detectors have used Application Specific Integrated Circuits (ASIC) in their electronics readout system and ASICs have been designed in China now. This project designed a multi-channel readout ASIC for general detector. The chip has Preamplifier, Shaper and Peak Detector embedded for easy readout. For each channel, signal which is preprocessed by a low-noise preamplifier is sent to the shaper to form a quasi-Gaussian pulse and keep its peak for readout. This chip and modules of individual Preamplifier, Shaper and Peak Detector have been manufactured, results will be reported in time. (authors)

  17. Front-end electronics and readout system for the ILD TPC

    CERN Document Server

    Hedberg, V; Lundberg, B; Mjörnmark, U; Oskarsson, A; Österman, L; De Lentdecker, G; Yang, Y; Zhang, F

    2015-01-01

    A high resolution TPC is the main option for a central tracking detector at the future International Linear Collider (ILC). It is planned that the MPGD (Micro Pattern Gas Detector) technology will be used for the readout. A Large Prototype TPC at DESY has been used to test the performance of MPGDs in an electron beam of energies up to 6 GeV. The first step in the technology development was to demonstrate that the MPGDs are able to achieve the necessary performance set by the goals of ILC. For this ’proof of principle’ phase, the ALTRO front-end electronics from the ALICE TPC was used, modified to adapt to MPGD readout. The proof of principle has been verified and at present further improvement of the MPGD technology is going on, using the same readout electronics. The next step is the ’feasibility phase’, which aims at producing front-end electronics comparable in size (few mm2) to the readout pads of the TPC. This development work is based on the succeeding SALTRO16 chip, which combines the analogue ...

  18. High resolution ADC interface to main magnet power supply at the NSLS

    International Nuclear Information System (INIS)

    Bordoley, M.

    1993-01-01

    Previous readings of DCCT were limited to 11 bits of resolution with large offsets and drifts, providing inaccurate data. The current design overcomes this limitation by using Analog Device's AD7703 20 bit serial output ADC to digitize the main magnet DCCT at the power supply, and transmit the data serially at 2KHz over to the VME controller

  19. Electrical design note for a 5000 ADC, 230 μH power supply filter choke

    International Nuclear Information System (INIS)

    Visser, A.T.

    1993-04-01

    This note describes the design of a 5000 ADC, 230 μH choke made from standard transformer cores. Five of these chokes have been made for CDF and MTF. NOTE: Special magnets can also be made using standard cores

  20. Digital readouts for large microwave low-temperature detector arrays

    International Nuclear Information System (INIS)

    Mazin, Benjamin A.; Day, Peter K.; Irwin, Kent D.; Reintsema, Carl D.; Zmuidzinas, Jonas

    2006-01-01

    Over the last several years many different types of low-temperature detectors (LTDs) have been developed that use a microwave resonant circuit as part of their readout. These devices include microwave kinetic inductance detectors (MKID), microwave SQUID readouts for transition edge sensors (TES), and NIS bolometers. Current readout techniques for these devices use analog frequency synthesizers and IQ mixers. While these components are available as microwave integrated circuits, one set is required for each resonator. We are exploring a new readout technique for this class of detectors based on a commercial-off-the-shelf technology called software defined radio (SDR). In this method a fast digital to analog (D/A) converter creates as many tones as desired in the available bandwidth. Our prototype system employs a 100MS/s 16-bit D/A to generate an arbitrary number of tones in 50MHz of bandwidth. This signal is then mixed up to the desired detector resonant frequency (∼10GHz), sent through the detector, then mixed back down to baseband. The baseband signal is then digitized with a series of fast analog to digital converters (80MS/s, 14-bit). Next, a numerical mixer in a dedicated integrated circuit or FPGA mixes the resonant frequency of a specified detector to 0Hz, and sends the complex detector output over a computer bus for processing and storage. In this paper we will report on our results in using a prototype system to readout a MKID array, including system noise performance, X-ray pulse response, and cross-talk measurements. We will also discuss how this technique can be scaled to read out many thousands of detectors