WorldWideScience

Sample records for samples tested positive

  1. Microbiological evaluation of milk samples positive to California Mastitis Test in dairy buffalo cows (Buballus bubalis

    Directory of Open Access Journals (Sweden)

    D.J. Sturion

    2010-02-01

    Full Text Available In order to observe the microbiological status of CMT positive samples, 734 apparently health mammary quarters from buffalo cows were submitted to physical evaluation, strip cup test and CMT. After milk samples inoculation in 10% ovine blood agar base media and in MacConkey agar and incubation under aerobic condition for 72 hours at 37oC, identification was proceeded. According to CMT, 227 quarters (30,93% were positive, among them 73 (32,16% presented 1+ reaction, 53 (23,35% were 2+ and 101 (44,49% were 3+. Microbiological exams of such samples were positive in 147 (64,76% out of 227 CMT positive samples and among the remaining 72 (31,72% were negative and 8 (3,52 were contaminated. In the 147 microbiological positive samples 204 bacteria were found in pure or associated growth and the most frequent agents were: Corynebacterium sp (59,25%; Staphylococcus sp (17,65% among which 86,11% were coagulase negative and 13,89% were coagulase positive; and Micrococcus sp (6,37%. The results revealed that, excluding the eight contaminated samples, 147 (67,12% quarters out of 219 CMT positive could be considered as bacteria-carrier and that even in a smaller percentage false-positive results can cause problems in a sanitary program for mastitis control in dairy buffalo cows.

  2. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  3. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  4. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  5. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures.

    Science.gov (United States)

    Pan, Hong-Wei; Li, Wei; Li, Rong-Guo; Li, Yong; Zhang, Yi; Sun, En-Hua

    2018-01-01

    Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  6. Simple Sample Preparation Method for Direct Microbial Identification and Susceptibility Testing From Positive Blood Cultures

    Directory of Open Access Journals (Sweden)

    Hong-wei Pan

    2018-03-01

    Full Text Available Rapid identification and determination of the antibiotic susceptibility profiles of the infectious agents in patients with bloodstream infections are critical steps in choosing an effective targeted antibiotic for treatment. However, there has been minimal effort focused on developing combined methods for the simultaneous direct identification and antibiotic susceptibility determination of bacteria in positive blood cultures. In this study, we constructed a lysis-centrifugation-wash procedure to prepare a bacterial pellet from positive blood cultures, which can be used directly for identification by matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS and antibiotic susceptibility testing by the Vitek 2 system. The method was evaluated using a total of 129 clinical bacteria-positive blood cultures. The whole sample preparation process could be completed in <15 min. The correct rate of direct MALDI-TOF MS identification was 96.49% for gram-negative bacteria and 97.22% for gram-positive bacteria. Vitek 2 antimicrobial susceptibility testing of gram-negative bacteria showed an agreement rate of antimicrobial categories of 96.89% with a minor error, major error, and very major error rate of 2.63, 0.24, and 0.24%, respectively. Category agreement of antimicrobials against gram-positive bacteria was 92.81%, with a minor error, major error, and very major error rate of 4.51, 1.22, and 1.46%, respectively. These results indicated that our direct antibiotic susceptibility analysis method worked well compared to the conventional culture-dependent laboratory method. Overall, this fast, easy, and accurate method can facilitate the direct identification and antibiotic susceptibility testing of bacteria in positive blood cultures.

  7. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    International Nuclear Information System (INIS)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-01-01

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  8. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-09-15

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  9. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  10. Sample positioning effects in x-ray spectrometry

    International Nuclear Information System (INIS)

    Carpenter, D.

    Instrument error due to variation in sample position in a crystal x-ray spectrometer can easily exceed the total instrumental error. Lack of reproducibility in sample position in the x-ray optics is the single largest source of system error. The factors that account for sample positioning error are described, and many of the details of flat crystal x-ray optics are discussed

  11. The influence of body position on Bielschowsky's test

    Directory of Open Access Journals (Sweden)

    Carlos R. Souza-Dias

    2014-04-01

    Full Text Available Purpose: To investigate the veracity of Jampolsky's statement that Bielschowsky's head tilt test is inverted if performed with the patient in the upside-down position and to interpret its neuromuscular mechanism. Methods: We present a series of 10 patients selected from a referred sample who were diagnosed with superior oblique paresis. Hypertropia was measured in the primary position, with the head erect and tilted toward both shoulders with the patient in the erect, supine, and upside-down positions. The last position was achieved by hanging the patient upside-down. Results: As expected, our results showed the veracity of Jampolsky's statement. The forced head tilt difference was inverted or significantly decreased when the test was performed in the upside-down position. Moreover, in all patients, Bielschowsky's phenomenon was neutralized in the supine body position, in which hypertropia with the head erect tended to vanish. In 3 patients, it disappeared completely. Conclusions: This study showed that, in patients with superior oblique paresis, differences in the extent of hypertropia in Bielschowsky's test tended to vanish when the test was performed with the patient in the supine position and invert when it was performed with the patient in the upside-down position.

  12. Mineralogic and petrologic investigation of post-test core samples from the Spent Fuel Test - Climax

    International Nuclear Information System (INIS)

    Ryerson, F.J.; Beiriger, J.

    1985-02-01

    We have characterized a suite of samples taken subsequent to the end of the Spent Fuel Test - Climax by petrographic and microanalytical techniques and determined their mineral assemblage, modal properties, and mineral chemistry. The samples were obtained immediately adjacent to the canister borehole at a variety of depths and positions within the canister drift, as well as radially outward from each canister hole. This method of sampling allows variations in post-test mineralogic properties to be evaluated on the basis of (1) depth along a particular canister hole and (2) position within the canister drift, with respect to the heat and radiation sources, and with respect to the pre - test samples. In no case did we find any significant correlation between the mineralogical properties and variables listed above. In short, the Spent Fuel Test - Climax has produced no identifiable mineralogical response in the Climax quartz monzonite. 12 refs., 11 figs., 5 tabs

  13. The false positive exercise test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro; Matsuda, Yasuo; Ozaki, Masaharu; Ogawa, Hiroshi; Ichiyama, Masaji; Matsuda, Masako; Kusukawa, Reizo

    1986-01-01

    Exercise tests with sublingual nitroglycerin were performed on 7 patients with true positive and 8 patients with false positive exercise test results. Four of 7 patients with true positive changes and 8 patients with false positive changes underwent exercise cardiac scintigraphy. Scintigrams showed perfusion defects in 4 patients with true positive outcomes, and no perfusion defect in 8 patients with false positive outcomes. Exercise tests with sublingual nitroglycerin were performed with the same load as that without nitroglycerin. In all 7 patients with true positive exercise test results, ST segment depression observed in the control exercise test was not observed in the nitroglycerin exercise test. In the false positive patients, ST segment depression observed in the control exercise test remained unchanged in 7 of 8 patients receiving nitroglycerin. Exercise tests with sublingual nitroglycerin as well as exercise cardiac scintigraphy are valuable tods in differentiating false positive from true positive patients. Furthermore, these data suggest that ST segment depression in the false positive patients may not be related to myocardial ischemia. (author)

  14. Testing predictive models of positive and negative affect with psychosocial, acculturation, and coping variables in a multiethnic undergraduate sample.

    Science.gov (United States)

    Kuo, Ben Ch; Kwantes, Catherine T

    2014-01-01

    Despite the prevalence and popularity of research on positive and negative affect within the field of psychology, there is currently little research on affect involving the examination of cultural variables and with participants of diverse cultural and ethnic backgrounds. To the authors' knowledge, currently no empirical studies have comprehensively examined predictive models of positive and negative affect based specifically on multiple psychosocial, acculturation, and coping variables as predictors with any sample populations. Therefore, the purpose of the present study was to test the predictive power of perceived stress, social support, bidirectional acculturation (i.e., Canadian acculturation and heritage acculturation), religious coping and cultural coping (i.e., collective, avoidance, and engagement coping) in explaining positive and negative affect in a multiethnic sample of 301 undergraduate students in Canada. Two hierarchal multiple regressions were conducted, one for each affect as the dependent variable, with the above described predictors. The results supported the hypotheses and showed the two overall models to be significant in predicting affect of both kinds. Specifically, a higher level of positive affect was predicted by a lower level of perceived stress, less use of religious coping, and more use of engagement coping in dealing with stress by the participants. Higher level of negative affect, however, was predicted by a higher level of perceived stress and more use of avoidance coping in responding to stress. The current findings highlight the value and relevance of empirically examining the stress-coping-adaptation experiences of diverse populations from an affective conceptual framework, particularly with the inclusion of positive affect. Implications and recommendations for advancing future research and theoretical works in this area are considered and presented.

  15. 30 CFR 71.208 - Bimonthly sampling; designated work positions.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bimonthly sampling; designated work positions... UNDERGROUND COAL MINES Sampling Procedures § 71.208 Bimonthly sampling; designated work positions. (a) Each... standard when quartz is present), respirable dust sampling of designated work positions shall begin on the...

  16. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Directory of Open Access Journals (Sweden)

    Van den Ende Jef

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostic tests (RDTs are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74% RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20, and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs. Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.

  17. Detection of drugs in 275 alcohol-positive blood samples of Korean drivers.

    Science.gov (United States)

    Kim, Eunmi; Choe, Sanggil; Lee, Juseon; Jang, Moonhee; Choi, Hyeyoung; Chung, Heesun

    2016-08-01

    Since driving under the influence of drugs (DUID) is as dangerous as drink-driving, many countries regulate DUID by law. However, laws against the use of drugs while driving are not yet established in Korea. In order to investigate the type and frequency of drugs used by drivers in Korea, we analyzed controlled and non-controlled drugs in alcohol-positive blood samples. Total 275 blood samples were taken from Korean drivers, which were positive in roadside alcohol testing. The following analyses were performed: blood alcohol concentrations by GC; screening for controlled drugs by immunoassay and confirmation for positive samples by GC-MS. For the detection of DUID related drugs in blood samples, a total of 49 drugs were selected and were examined by GC-MS. For a rapid detection of these drugs, an automated identification software called "DrugMan" was used. Concentrations of alcohol in 275 blood samples ranged from 0.011 to 0.249% (average 0.119%). Six specimens showed positive results by immunoassay: one methamphetamine and five benzodiazepines I. By GC-MS confirmation, only benzodiazepines in four cases were identified, while methamphetamine and benzodiazepine in two cases were not detected from the presumptive positive blood samples. Using DrugMan, four drugs were detected; chlorpheniramine (5)*, diazepam (4), dextromethorphan (1) and doxylamine (1). In addition, ibuprofen (1), lidocaine (1) and topiramate (1) were also detected as general drugs in blood samples ('*' indicates frequency). The frequency of drug abuse by Korean drivers was relatively low and a total 14 cases were positive in 275 blood samples with a ratio of 5%. However it is necessary to analyze more samples including alcohol negative blood, and to expand the range of drug lists to get the detailed information. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Perfectionism, Performance, and State Positive Affect and Negative Affect after a Classroom Test

    Science.gov (United States)

    Flett, Gordon L.; Blankstein, Kirk R.; Hewitt, Paul L.

    2009-01-01

    The current study examined the associations among trait dimensions of perfectionism, test performance, and levels of positive and negative affect after taking a test. A sample of 92 female university students completed the Multidimensional Perfectionism Scale one week prior to an actual class test. Measures of positive affect and negative affect…

  19. PCR-based verification of positive rapid diagnostic tests for intestinal protozoa infections with variable test band intensity.

    Science.gov (United States)

    Becker, Sören L; Müller, Ivan; Mertens, Pascal; Herrmann, Mathias; Zondie, Leyli; Beyleveld, Lindsey; Gerber, Markus; du Randt, Rosa; Pühse, Uwe; Walter, Cheryl; Utzinger, Jürg

    2017-10-01

    Stool-based rapid diagnostic tests (RDTs) for pathogenic intestinal protozoa (e.g. Cryptosporidium spp. and Giardia intestinalis) allow for prompt diagnosis and treatment in resource-constrained settings. Such RDTs can improve individual patient management and facilitate population-based screening programmes in areas without microbiological laboratories for confirmatory testing. However, RDTs are difficult to interpret in case of 'trace' results with faint test band intensities and little is known about whether such ambiguous results might indicate 'true' infections. In a longitudinal study conducted in poor neighbourhoods of Port Elizabeth, South Africa, a total of 1428 stool samples from two cohorts of schoolchildren were examined on the spot for Cryptosporidium spp. and G. intestinalis using an RDT (Crypto/Giardia DuoStrip; Coris BioConcept). Overall, 121 samples were positive for G. intestinalis and the RDT suggested presence of cryptosporidiosis in 22 samples. After a storage period of 9-10 months in cohort 1 and 2-3 months in cohort 2, samples were subjected to multiplex PCR (BD Max™ Enteric Parasite Panel, Becton Dickinson). Ninety-three percent (112/121) of RDT-positive samples for G. intestinalis were confirmed by PCR, with a correlation between RDT test band intensity and quantitative pathogen load present in the sample. For Cryptosporidium spp., all positive RDTs had faintly visible lines and these were negative on PCR. The performance of the BD Max™ PCR was nearly identical in both cohorts, despite the prolonged storage at disrupted cold chain conditions in cohort 1. The Crypto/Giardia DuoStrip warrants further validation in communities with a high incidence of diarrhoea. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Direct detection of Trichomonas vaginalis virus in Trichomonas vaginalis positive clinical samples from the Netherlands.

    Science.gov (United States)

    Jehee, Ivo; van der Veer, Charlotte; Himschoot, Michelle; Hermans, Mirjam; Bruisten, Sylvia

    2017-12-01

    Trichomonas vaginalis is the most common sexually transmitted parasitical infection worldwide. T. vaginalis can carry a virus: Trichomonas vaginalis virus (TVV). To date, four TVV species have been described. Few studies have investigated TVV prevalence and its clinical importance. We have developed a nested reverse-transcriptase PCR, with novel, type specific primers to directly detect TVV RNA in T. vaginalis positive clinical samples. A total of 119T. vaginalis positive clinical samples were collected in Amsterdam and "s-Hertogenbosch, the Netherlands, from 2012 to 2016. For all samples T. vaginalis was genotyped using multi-locus sequence typing. The T. vaginalis positive samples segregated into a two-genotype population: type I (n=64) and type II (n=55). All were tested for TVV with the new TVV PCR. We detected 3 of the 4 TVV species. Sequencing of the amplified products showed high homology with published TVV genomes (82-100%). Half of the T. vaginalis clinical samples (n=60, 50.4%) were infected with one or more TVV species, with a preponderance for TVV infections in T. vaginalis type I (n=44, 73.3%). Clinical data was available for a subset of samples (n=34) and we observed an association between testing positive for (any) TVV and reporting urogenital symptoms (p=0.023). The nested RT-PCR allowed for direct detection of TVV in T. vaginalis positive clinical samples. This may be helpful in studies and clinical settings, since T. vaginalis disease and/or treatment outcome may be influenced by the protozoa"s virus. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Evaluation of rapid diagnostic test kits for feline leukemia virus infection using samples from naturally infected cats

    Directory of Open Access Journals (Sweden)

    Jiayou Liu

    2016-09-01

    Full Text Available Objectives Feline leukemia virus (FeLV is a potentially life-threatening oncogenic retrovirus. The p27 viral core protein is produced by the virus in infected feline cells, is found in the cytoplasm in several blood cells and can be free in the serum and plasma. ELISA or particle-based immunoassay are commonly used to detect the presence of the p27 core protein in samples obtained from blood. The objective of this study was to compare the performance of several in-clinic tests: the SNAP Feline Triple Test (IDEXX Laboratories, the WITNESS FeLV-FIV Test (Zoetis and the VetScan Feline FeLV/FIV Rapid Test (Abaxis. Methods The sample population (100 positive, 105 negative samples consisted of serum and plasma samples submitted to IDEXX’s worldwide reference laboratory for feline retrovirus testing. Virus isolation and reverse transcriptase PCR results were not available and so samples were judged to be positive or negative based on the results of the ViraCHEK FeLV (Zoetis microtiter plate assay. Results The percentage of samples positive and negative for FeLV p27 antigen using the three in-clinic tests compared with the ViraCHEK method were as follows: IDEXX Feline Triple (positive 98.0%, negative 100%; Zoetis WITNESS (positive 79.0%, negative 97.1%; Abaxis VetScan (positive 73.0%, negative 97.1%. Conclusions and relevance The SNAP Feline Triple Test demonstrated a high level of agreement for FeLV-positive and FeLV-negative samples when assessed in this model. Results of FeLV assays can vary among tests.

  2. Evaluation of rapid diagnostic test kits for feline leukemia virus infection using samples from naturally infected cats.

    Science.gov (United States)

    Liu, Jiayou; O'Connor, Thomas; Beall, Melissa; Chandrashekar, Ramaswamy; Lappin, Michael

    2016-01-01

    Feline leukemia virus (FeLV) is a potentially life-threatening oncogenic retrovirus. The p27 viral core protein is produced by the virus in infected feline cells, is found in the cytoplasm in several blood cells and can be free in the serum and plasma. ELISA or particle-based immunoassay are commonly used to detect the presence of the p27 core protein in samples obtained from blood. The objective of this study was to compare the performance of several in-clinic tests: the SNAP Feline Triple Test (IDEXX Laboratories), the WITNESS FeLV-FIV Test (Zoetis) and the VetScan Feline FeLV/FIV Rapid Test (Abaxis). The sample population (100 positive, 105 negative samples) consisted of serum and plasma samples submitted to IDEXX's worldwide reference laboratory for feline retrovirus testing. Virus isolation and reverse transcriptase PCR results were not available and so samples were judged to be positive or negative based on the results of the ViraCHEK FeLV (Zoetis) microtiter plate assay. The percentage of samples positive and negative for FeLV p27 antigen using the three in-clinic tests compared with the ViraCHEK method were as follows: IDEXX Feline Triple (positive 98.0%, negative 100%); Zoetis WITNESS (positive 79.0%, negative 97.1%); Abaxis VetScan (positive 73.0%, negative 97.1%). The SNAP Feline Triple Test demonstrated a high level of agreement for FeLV-positive and FeLV-negative samples when assessed in this model. Results of FeLV assays can vary among tests.

  3. Estimation of sample size and testing power (Part 3).

    Science.gov (United States)

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2011-12-01

    This article introduces the definition and sample size estimation of three special tests (namely, non-inferiority test, equivalence test and superiority test) for qualitative data with the design of one factor with two levels having a binary response variable. Non-inferiority test refers to the research design of which the objective is to verify that the efficacy of the experimental drug is not clinically inferior to that of the positive control drug. Equivalence test refers to the research design of which the objective is to verify that the experimental drug and the control drug have clinically equivalent efficacy. Superiority test refers to the research design of which the objective is to verify that the efficacy of the experimental drug is clinically superior to that of the control drug. By specific examples, this article introduces formulas of sample size estimation for the three special tests, and their SAS realization in detail.

  4. Determination of specificity and pattern of antinuclear antibodies (ana) in systemic rheumatic disease patients positive for ana testing

    International Nuclear Information System (INIS)

    Nawaz, H.; Bashir, M.M.; Iqbal, W.

    2018-01-01

    To determine probability of finding antinuclear antibodies (ANA) and anti extractable nuclear antigens (ENA) positive samples and associating ANA patterns with anti-ENA reactivities among a consecutive cohort of samples of systemic rheumatic disease patients referred for ANA testing. Study Design:Prospective cohort study. Place and Duration of Study:Immunology Department, Armed Forces Institute of Pathology, Rawalpindi, Pakistan, from January to June 2016. Methodology:All the samples referred for ANA testing with clinical suspicion of systemic rheumatic disease were included. After screening, ANA positive samples were subjected to anti-ENA antibodies testing (including anti-SSA, anti-SSB, anti-Sm, anti-RNP, anti-SCL-70 and anti-Jo-1 antibodies) and ANA pattern and titer determination. Results:Of 4,347 samples received, 397 were positive for ANA (9%). Of 397, 96 (24%) samples positive on ENA screen were tested for anti-ENA reactivity. Anti-SSA antibodies were found in 59 samples. Commonest ANA patterns were coarse and fine speckled (43 and 22 samples of 81 tested), while majority of samples carried ANA in titers of 1:40 and 1:80 (22 and 18 samples of 81 tested). No specific ANA pattern was associated with any particular anti-ENA reactivity. Conclusion:Among samples/patients referred for investigations of autoimmune disorders, probability of finding positive ANA is approximately 9%. Of these 9%, about 24% also show reactivity against ENA. Commonest ANA pattern is coarse speckled and majority of such patients carry ANA in titers ranging from 1:40 to 1:80. Commonest ENA reactivity was against SSA. (author)

  5. Innovative directional and position specific sampling technique

    International Nuclear Information System (INIS)

    Hutzel, W.J.; Hill, J.L. III; Foster, E.L.

    1994-01-01

    UTD, Incorporated has developed a unique real-time, in-situ POsition LOcation (POLO) device which will directly enhance the Department of Energy's Environmental Restoration and Waste Management Program through improvements to finding contamination, identifying extent of contamination, remediating, and finally monitoring sites. POLO is smaller than existing technology and is unaffected by the presence of steel and other magnetic materials. The size of the device offers for the first time, the possibility to accurately determine the location of a penetrometer. It will be usable, in its present form, to map the position of a sampling device as that device is inserted into the ground. A three phase program was proposed to DOE to take the POLO System through the three levels of maturity prior to commercialization. Phase 1 included the design and testing of individual components of the device and met or exceeded success criteria. Phase 2 has included laboratory-scale tracking experiments of the integrated POLO System that have met or exceeded the success criterion as well. The success criterion is to demonstrate path tracking accuracy with a total error of less than 0.50% of the distance traveled for distances less than 70 meters. In Phase 3 we will develop and test a full-scale POLO System and conclude with a field demonstration. The goal of the Phase 3 effort is to achieve the same 0.50% accuracy or better with respect to the distance traveled for distances less than 70 meters in the field as was demonstrated in laboratory tests in the earlier phases. The final report details the design of a realistic laboratory-scale penetrometer path and describes the POLO tracking experiments that were conducted. Plans for demonstrations as well as commercialization and technology transfer with DOE field sites are described, highlighting the expected smooth transition to full-scale production

  6. Prospective assessment of the false positive rate of the Australian snake venom detection kit in healthy human samples.

    Science.gov (United States)

    Nimorakiotakis, Vasilios Bill; Winkel, Kenneth D

    2016-03-01

    The Snake Venom Detection Kit (SVDK; bioCSL Pty Ltd, Australia) distinguishes venom from the five most medically significant snake immunotypes found in Australia. This study assesses the rate of false positives that, by definition, refers to a positive assay finding in a sample from someone who has not been bitten by a venomous snake. Control unbroken skin swabs, simulated bite swabs and urine specimens were collected from 61 healthy adult volunteers [33 males and 28 females] for assessment. In all controls, simulated bite site and urine samples [a total of 183 tests], the positive control well reacted strongly within one minute and no test wells reacted during the ten minute incubation period. However, in two urine tests, the negative control well gave a positive reaction (indicating an uninterpretable test). A 95% confidence interval for the false positive rate, on a per-patient rate, derived from the findings of this study, would extend from 0% to 6% and, on a per-test basis, it would be 0-2%. It appears to be a very low incidence (0-6%) of intrinsic true false positives for the SVDK. The clinical impresssion of a high SVDK false positive rate may be mostly related to operator error. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  7. Sample intake position and loading rates from nonpoint source pollution

    Science.gov (United States)

    McGuire, P. E.; Daniel, T. C.; Stoffel, D.; Andraski, B.

    1980-01-01

    Paired water samples were simultaneously activated from two different vertical positions within the approach section of a flow-control structure to determine the effect of sample intake position on nonpoint runoff parameter concentrations and subsequent event loads. Suspended solids (SS), total phosphorus (TP) and organic plus exchangeable nitrogen [(Or+Ex)-N] were consistently higher throughout each runoff event when sampled from the floor of the approach section as opposed to those samples taken at midstage. Dissolved molybdate reactive phosphorus (DMRP) and ammonium (NH4-N) concentrations did not appear to be significantly affected by the vertical difference in intake position. However, the nitrate plus nitrite nitrogen [(NO3+NO2)-N] concentrations were much higher when sampled from the midstage position. Although the concentration differences between the two methods were not appreciable, when evaluated in terms of event loads, discrepancies were evident for all parameters. Midstage sampling produced event loads for SS, TP, (Or + Ex)-N, DMRP, NH4-N, and (NO3+NO2)-N that were 44,39,35,80,71, and 181%, respectively, of floor sampling loads. Differences in loads between the two methods are attributed to the midstage position, sampling less of the bed load. The correct position will depend on the objective; however, such differences should be recognized during the design phase of the monitoring program.

  8. Influence of Sample Size on Automatic Positional Accuracy Assessment Methods for Urban Areas

    Directory of Open Access Journals (Sweden)

    Francisco J. Ariza-López

    2018-05-01

    Full Text Available In recent years, new approaches aimed to increase the automation level of positional accuracy assessment processes for spatial data have been developed. However, in such cases, an aspect as significant as sample size has not yet been addressed. In this paper, we study the influence of sample size when estimating the planimetric positional accuracy of urban databases by means of an automatic assessment using polygon-based methodology. Our study is based on a simulation process, which extracts pairs of homologous polygons from the assessed and reference data sources and applies two buffer-based methods. The parameter used for determining the different sizes (which range from 5 km up to 100 km has been the length of the polygons’ perimeter, and for each sample size 1000 simulations were run. After completing the simulation process, the comparisons between the estimated distribution functions for each sample and population distribution function were carried out by means of the Kolmogorov–Smirnov test. Results show a significant reduction in the variability of estimations when sample size increased from 5 km to 100 km.

  9. [Mes differ by positioning: empirical testing of decentralized dynamics of the self].

    Science.gov (United States)

    Mizokami, Shinichi

    2013-10-01

    The present study empirically tested the conceptualization of the decentralized dynamics of the self proposed by Hermans & Kempen (1993), which they developed theoretically and from clinical cases, not from large samples of empirical data. They posited that worldviews and images of the self could vary by positioning even in the same individual, and denied that the ego was an omniscient entity that knew and controlled all aspects of the self (centralized ego). Study 1 tested their conceptualization empirically with 47 university students in an experimental group and 17 as a control group. The results showed that the scores on the Rosenberg's self-esteem scale and images of the Mes in the experimental group significantly varied by positioning, but those in the control group did not. Similar results were found in Study 2 with a sample of 120 university students. These results empirically supported the conceptualization of the decentralized dynamics of the self.

  10. Sampling analytical tests and destructive tests for quality assurance

    International Nuclear Information System (INIS)

    Saas, A.; Pasquini, S.; Jouan, A.; Angelis, de; Hreen Taywood, H.; Odoj, R.

    1990-01-01

    In the context of the third programme of the European Communities on the monitoring of radioactive waste, various methods have been developed for the performance of sampling and measuring tests on encapsulated waste of low and medium level activity, on the one hand, and of high level activity, on the other hand. The purpose was to provide better quality assurance for products to be stored on an interim or long-term basis. Various testing sampling means are proposed such as: - sampling of raw waste before conditioning and determination of the representative aliquot, - sampling of encapsulated waste on process output, - sampling of core specimens subjected to measurement before and after cutting. Equipment suitable for these sampling procedures have been developed and, in the case of core samples, a comparison of techniques has been made. The results are described for the various analytical tests carried out on the samples such as: - mechanical tests, - radiation resistance, - fire resistance, - lixiviation, - determination of free water, - biodegradation, - water resistance, - chemical and radiochemical analysis. Every time it was possible, these tests were compared with non-destructive tests on full-scale packages and some correlations are given. This word has made if possible to improve and clarify sample optimization, with fine sampling techniques and methodologies and draw up characterization procedures. It also provided an occasion for a first collaboration between the laboratories responsible for these studies and which will be furthered in the scope of the 1990-1994 programme

  11. Positive Skin Test or Specific IgE to Penicillin Does Not Reliably Predict Penicillin Allergy.

    Science.gov (United States)

    Tannert, Line Kring; Mortz, Charlotte Gotthard; Skov, Per Stahl; Bindslev-Jensen, Carsten

    According to guidelines, patients are diagnosed with penicillin allergy if skin test (ST) result or specific IgE (s-IgE) to penicillin is positive. However, the true sensitivity and specificity of these tests are presently not known. To investigate the clinical relevance of a positive ST result and positive s-IgE and to study the reproducibility of ST and s-IgE. A sample of convenience of 25 patients with positive penicillin ST results, antipenicillin s-IgE results, or both was challenged with their culprit penicillin. Further 19 patients were not challenged, but deemed allergic on the basis of a recent anaphylactic reaction or delayed reactions to skin testing. Another sample of convenience of 18 patients, 17 overlapping with the 25 challenged, with initial skin testing and s-IgE (median, 25; range, 3-121), months earlier (T -1 ), was repeat skin tested and had s-IgE measured (T 0 ), and then skin tested and had s-IgE measured 4 weeks later (T 1 ). Only 9 (36%) of 25 were challenge positive. There was an increased probability of being penicillin allergic if both ST result and s-IgE were positive at T 0 . Positive ST result or positive s-IgE alone did not predict penicillin allergy. Among the 18 patients repeatedly tested, 46.2% (12 of 25) of positive ST results at T -1 were reproducibly positive at T 0 . For s-IgE, 54.2% (14 of 24) positive measurements were still positive at T 0 and 7 converted to positive at T 1 . The best predictor for a clinically significant (IgE-mediated) penicillin allergy is a combination of a positive case history with simultaneous positive ST result and s-IgE or a positive challenge result. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  12. Bovine milk sampling efficiency for pregnancy-associated glycoproteins (PAG) detection test

    Energy Technology Data Exchange (ETDEWEB)

    Silva, H. K. da; Cassoli, L.D.; Pantoja, J.F.C.; Cerqueira, P.H.R.; Coitinho, T.B.; Machado, P.F.

    2016-07-01

    Two experiments were conducted to verify whether the time of day at which a milk sample is collected and the possible carryover in the milking system may affect pregnancy-associated glycoproteins (PAG) levels and, consequently, the pregnancy test results in dairy cows. In experiment one, we evaluated the effect of time of day at which the milk sample is collected from 51 cows. In experiment two, which evaluated the possible occurrence of carryover in the milk meter milking system, milk samples from 94 cows belonging to two different farms were used. The samples were subjected to pregnancy test using ELISA methodology to measure PAG concentrations and to classify the samples as positive (pregnant), negative (nonpregnant), or suspicious (recheck). We found that the time of milking did not affect the PAG levels. As to the occurrence of carryover in the milk meter, the PAG levels of the samples collected from Farm-2 were heavily influenced by a carryover effect compared with the samples from Farm-1. Thus, milk samples submitted to a pregnancy test can be collected during the morning or the evening milking. When the sample is collected from the milk meters, periodic equipment maintenance should be noted, including whether the milk meter is totally drained between different animals’ milking and equipment cleaning between milking is performed correctly to minimize the occurrence of carryover, thereby avoiding the effect on PAG levels and, consequently, the pregnancy test results. Therefore, a single milk sample can be used for both milk quality tests and pregnancy test.

  13. Bovine milk sampling efficiency for pregnancy-associated glycoproteins (PAG) detection test

    International Nuclear Information System (INIS)

    Silva, H. K. da; Cassoli, L.D.; Pantoja, J.F.C.; Cerqueira, P.H.R.; Coitinho, T.B.; Machado, P.F.

    2016-01-01

    Two experiments were conducted to verify whether the time of day at which a milk sample is collected and the possible carryover in the milking system may affect pregnancy-associated glycoproteins (PAG) levels and, consequently, the pregnancy test results in dairy cows. In experiment one, we evaluated the effect of time of day at which the milk sample is collected from 51 cows. In experiment two, which evaluated the possible occurrence of carryover in the milk meter milking system, milk samples from 94 cows belonging to two different farms were used. The samples were subjected to pregnancy test using ELISA methodology to measure PAG concentrations and to classify the samples as positive (pregnant), negative (nonpregnant), or suspicious (recheck). We found that the time of milking did not affect the PAG levels. As to the occurrence of carryover in the milk meter, the PAG levels of the samples collected from Farm-2 were heavily influenced by a carryover effect compared with the samples from Farm-1. Thus, milk samples submitted to a pregnancy test can be collected during the morning or the evening milking. When the sample is collected from the milk meters, periodic equipment maintenance should be noted, including whether the milk meter is totally drained between different animals’ milking and equipment cleaning between milking is performed correctly to minimize the occurrence of carryover, thereby avoiding the effect on PAG levels and, consequently, the pregnancy test results. Therefore, a single milk sample can be used for both milk quality tests and pregnancy test.

  14. Positive cell-free fetal DNA testing for trisomy 13 reveals confined placental mosaicism.

    Science.gov (United States)

    Hall, April L; Drendel, Holli M; Verbrugge, Jennifer L; Reese, Angela M; Schumacher, Katherine L; Griffith, Christopher B; Weaver, David D; Abernathy, Mary P; Litton, Christian G; Vance, Gail H

    2013-09-01

    We report on a case in which cell-free fetal DNA was positive for trisomy 13 most likely due to confined placental mosaicism. Cell-free fetal DNA testing analyzes DNA derived from placental trophoblast cells and can lead to incorrect results that are not representative of the fetus. We sought to confirm commercial cell-free fetal DNA testing results by chorionic villus sampling and amniocentesis. These results were followed up by postnatal chromosome analysis of cord blood and placental tissue. First-trimester cell-free fetal DNA test results were positive for trisomy 13. Cytogenetic analysis of chorionic villus sampling yielded a mosaic karyotype of 47,XY,+13[10]/46,XY[12]. G-banded analysis of amniotic fluid was normal, 46,XY. Postnatal cytogenetic analysis of cord blood was normal. Karyotyping of tissues from four quadrants of the placenta demonstrated mosaicism for trisomy 13 in two of the quadrants and a normal karyotype in the other two. Our case illustrates several important aspects of this new testing methodology: that cell-free fetal DNA may not be representative of the fetal karyotype; that follow-up with diagnostic testing of chorionic villus sampling and/or amniotic fluid for abnormal test results should be performed; and that pretest counseling regarding the full benefits, limitations, and possible testing outcomes of cell-free fetal DNA screening is important.

  15. [HPV primary test in the cervical cancer screening: reproducibility assessment and investigation on cytological outcome of Hybrid Capture 2 borderline samples].

    Science.gov (United States)

    Burroni, Elena; Sani, Cristina; Bisanzi, Simonetta; Ocello, Cristina

    2016-01-01

    to evaluate the reproducibility of the High-Risk Hybrid Capture 2 (HC2-HR, Qiagen) test within the frame of cervical cancer screening with HPV, for samples with values very close to the cut-off (borderline), that is 0.80≤RLU/CO≤0.99 (RLU/CO: relative light units/cut-off) and to assess any possible presence of high grade lesions. all borderline samples collected from January 2014 to August 2015 were repeated with HR-HC2 test within two weeks from the first test. For HPV-positive samples, cytology and colposcopy results (if present) were analysed. national and international directions recommend the use of HPV testing as a primary test for cervical cancer screening for women aged 30/34-64 years. In Tuscany Region (Central Italy) the primary screening with HPV test was introduced in 2013 and the HPV test currently used, HR-HC2, has a positive cut-off≥1 RLU/CO. proportion of HPV-positive tests at repetition, then stratified by type of material (ThinPrep, STM) and for the following subclasses of RLU/CO: 0.80-0.89 and 0.90-0.99. 253 samples were borderline at first test with HR-HC2 (about 0.4% of all samples tested). About 83% (209/253) of the samples was confirmed to be negative at the HPV test repetition: 88% for RLU/CO=0.80-0.89 and 76% for RLU/CO=0.90-0.99 (p-value=0.014). Median RLU/CO value of 44 HPV-positive samples at repetition is 1.4, with a maximum RLU/CO value of 16.7. In addition, 90% of HPV-positive samples at repetition has a RLU/CO values below or equal to 3.6. Even the used sampling system affects reproducibility: 26.4% (33/125) of the samples resulted positive at the repetition were in ThinPrep vs. 8.6% (11/128) of those in STM (p-valuecut-off (0.90-0.99), confirming the intrinsic limit to all analytical methods near to the cut-off. Moreover, even if the difference in reproducibility between the two systems of sampling is statistically significant, in samples that resulted positive at repetition high-grade lesions were not found at the time of HPV

  16. Classification of bacterial samples as negative or positive for a UTI and antibiogram using surface enhanced Raman spectroscopy

    Science.gov (United States)

    Kastanos, Evdokia; Hadjigeorgiou, Katerina; Kyriakides, Alexandros; Pitris, Costas

    2011-03-01

    Urinary tract infection (UTI) diagnosis requires an overnight culture to identify a sample as positive or negative for a UTI. Additional cultures are required to identify the pathogen responsible for the infection and to test its sensitivity to antibiotics. A rise in ineffective treatments, chronic infections, rising health care costs and antibiotic resistance are some of the consequences of this prolonged waiting period of UTI diagnosis. In this work, Surface Enhanced Raman Spectroscopy (SERS) is used for classifying bacterial samples as positive or negative for UTI. SERS spectra of serial dilutions of E.coli bacteria, isolated from a urine culture, were classified as positive (105-108 cells/ml) or negative (103-104 cells/ml) for UTI after mixing samples with gold nanoparticles. A leave-one-out cross validation was performed using the first two principal components resulting in the correct classification of 82% of all samples. Sensitivity of classification was 88% and specificity was 67%. Antibiotic sensitivity testing was also done using SERS spectra of various species of gram negative bacteria collected 4 hours after exposure to antibiotics. Spectral analysis revealed clear separation between the spectra of samples exposed to ciprofloxacin (sensitive) and amoxicillin (resistant). This study can become the basis for identifying urine samples as positive or negative for a UTI and determining their antibiogram without requiring an overnight culture.

  17. The effect of sample storage on the performance and reproducibility of the galactomannan EIA test.

    Science.gov (United States)

    Kimpton, George; White, P Lewis; Barnes, Rosemary A

    2014-08-01

    Galactomannan enzyme immune assay (GM EIA) is a nonculture test for detecting invasive aspergillosis (IA) forming a key part of diagnosis and management. Recent reports have questioned the reproducibility of indices after sample storage. To investigate this, 198 serum samples (72 from cases and 126 from controls) and 61 plasma samples (24 from cases and 37 from controls), initially tested between 2010 and 2013, were retested to determine any change in index. Data were also collected on circulatory protein levels for false-positive serum samples. Serum indices significantly declined on retesting (median: initial, 0.50, retest, 0.23; P < 0.0001). This was shown to be diagnosis dependent as the decline was apparent on retesting of control samples (median: initial 0.50, retest 0.12; P < 0.0001), but was not evident with case samples (median: initial, 0.80, retest, 0.80; P = 0.724). Plasma samples showed little change on reanalysis after long-term storage at 4°C. Retesting after freezing showed a decrease in index values for controls (median: initial 0.40, retest 0.26; P = 0.0505), but no significant change in cases. Circulatory proteins showed a correlation between serum albumin concentration and difference in index value on retesting. Overall, this study suggests that a lack of reproducibility in GM EIA positivity is only significant when disease is absent. Retesting after freezing helps to differentiate false-positive GM EIA results and, with consecutive positivity, could help to improve accuracy in predicting disease status. The freezing of samples prior to testing could potentially reduce false-positivity rates and the need to retest. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Exploring the Legionella pneumophila positivity rate in hotel water samples from Antalya, Turkey.

    Science.gov (United States)

    Sepin Özen, Nevgün; Tuğlu Ataman, Şenay; Emek, Mestan

    2017-05-01

    The genus Legionella is a fastidious Gram-negative bacteria widely distributed in natural waters and man made water supply systems. Legionella pneumophila is the aetiological agent of approximately 90% of reported Legionellosis cases, and serogroup 1 is the most frequent cause of infections. Legionnaires' disease is often associated with travel and continues to be a public health concern at present. The correct water management quality practices and rapid methods for analyzing Legionella species in environmental water is a key point for the prevention of Legionnaires' disease outbreaks. This study aimed to evaluate the positivity rates and serotyping of Legionella species from water samples in the region of Antalya, Turkey, which is an important tourism center. During January-December 2010, a total of 1403 samples of water that were collected from various hotels (n = 56) located in Antalya were investigated for Legionella pneumophila. All samples were screened for L. pneumophila by culture method according to "ISO 11731-2" criteria. The culture positive Legionella strains were serologically identified by latex agglutination test. A total of 142 Legionella pneumophila isolates were recovered from 21 (37.5%) of 56 hotels. The total frequency of L. pneumophila isolation from water samples was found as 10.1%. Serological typing of 142 Legionella isolates by latex agglutination test revealed that strains belonging to L. pneumophila serogroups 2-14 predominated in the examined samples (85%), while strains of L. pneumophila serogroup 1 were less numerous (15%). According to our knowledge, our study with the greatest number of water samples from Turkey demonstrates that L. pneumophila serogroups 2-14 is the most common isolate. Rapid isolation of L. pneumophila from environmental water samples is essential for the investigation of travel related outbreaks and the possible resources. Further studies are needed to have epidemiological data and to determine the types of L

  19. Etiology and Incidence of positive Microbiological tests in the Department of Pneumology

    Directory of Open Access Journals (Sweden)

    Carmela Mazzone

    2010-06-01

    Full Text Available The support of microbiological diagnosis for the management of the lower respiratory tract infections is of great utility. It is known, however, that for a correct therapeutic approach is essential to obtain clinical data and images diagnostic. Sometimes, in fact, to important clinical symptoms can coincide with microbiological results little worth, or the isolation from a sputum of certain bacteria, can be an expression of colonization or trivial contamination.The objective of this work was to evaluate the frequency of bacterial species responsible for respiratory tract infections, through direct (culture and indirect (serology methods. Between October 2007 - October 2008, 192 sputum cultures were examined, from the Department of Pneumology and out-patients.The isolation of bacterial strains was performed by seeding samples on the following media (Dasit: Columbia blood Agar (A. CNA, mannitol salt A., Wurtz lactose A., Sabouraud A., enriched chocolate A. + bacitracin. For serological tests, immunoassays in microplates (Vircell were used. The data show that of 192 samples deriving from Department of Pneumology, 41 (22% were positive, while among the out-patient samples, the percentage of positive cultures was 41% (20 positives on the total of 49 samples.The bacteria more frequently isolated in the department of Pneumology, was Pseudomonas aeruginosa (n.8 while in out-patients was Escherichia coli (n.8. Serological tests resulted positive for anti-Mycoplasma pneumoniae antibodies in 3 cases, and for anti-Chlamydia pneumoniae in one case, compared to 53 negative samples. The findings that over 75% of cultures have demonstrated negative results, is suggestive of an origin non-bacterial infections of the lower respiratory tract.Among the bacterial isolates are predominant “opportunistic bacteria” (46% presumably responsible of nosocomial infections, while in the out-patients are Enterobacteriaceae the prevalent microrganisms isolated.

  20. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    Science.gov (United States)

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  1. Test sample handling apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    A test sample handling apparatus using automatic scintillation counting for gamma detection, for use in such fields as radioimmunoassay, is described. The apparatus automatically and continuously counts large numbers of samples rapidly and efficiently by the simultaneous counting of two samples. By means of sequential ordering of non-sequential counting data, it is possible to obtain precisely ordered data while utilizing sample carrier holders having a minimum length. (U.K.)

  2. Experiences with an identification and quantification program for inhibitor-positive milk samples.

    Science.gov (United States)

    Kress, Claudia; Seidler, Caroline; Kerp, Bianca; Schneider, Elisabeth; Usleber, Ewald

    2007-03-14

    Beta-lactam antibiotics (penicillins, cephalosporins) are still the most commonly used antibiotics for dairy cows in Germany. In routine milk testing, according to the German milk quality regulation, a positive result obtained for bulk tank milk by microbiological inhibitor tests needs no further confirmation, but results in reduced milk payment of 0.05 euros kg(-1) for one month. In some cases, however, further identification of the causative agent can be of interest, either if antimicrobial drugs have not knowingly been used recently, or if improper use of such drugs is denied. As a service for milk producers, our laboratory offers further analyses of violative milk samples, aiming at the identification and quantification of the inhibitor(s). In this program, a panel of microbiological inhibitor tests, receptor tests, and enzyme immunoassays (EIA) is used in a step-by-step analysis, which primarily focusses on beta-lactams, but also includes other compounds such as sulfonamides or tetracyclines, respectively. Here we report results for violative milk samples (n=63) analysed between 2003 and 2005. In most cases (95%), beta-lactam antibiotics could be identified, although not always at levels exceeding the respective MRL values. Penicillin G (mostly together with benzylpenicilloyl metabolites) could be identified in 74.6% of all samples. Other compounds identified were, in decreasing order, ceftiofur (11%), ampicillin/amoxicillin (6.3%), isoxazolyl penicillins (3.2%), and sulfonamides (1.6%). The results indicate that penicillin G is still the predominant antibiotic responsible for violative bulk tank milk samples as detected during regulatory control.

  3. Daily self-sampling for high-risk human papillomavirus (HR-HPV) testing.

    Science.gov (United States)

    Sanner, Karin; Wikström, Ingrid; Gustavsson, Inger; Wilander, Erik; Lindberg, Julia Hedlund; Gyllensten, Ulf; Olovsson, Matts

    2015-12-01

    Self-sampling for HPV as part of primary screening is a well-tolerated method for women not attending organized Pap smear screening and could increase coverage of cervical cancer screening. To investigate if the prevalence of HR-HPV varies from day to day in infected women and if one single sample is reliable for detecting an ongoing infection. This is a prospective cohort study on 12 premenopausal and 13 postmenopausal women performing daily self-sampling for HR-HPV testing. They were all HR-HPV-positive 1-3 months ago. Postmenopausal women were sampled for 28 days and premenopausal women sampled during bleeding-free days in one menstrual cycle. A possible difference in viral load between the estrogen-dominated proliferative phase and the progesterone-dominated secretory phase was analyzed. Consistent results throughout the sampling period were observed for 19 women, with either a daily presence of HPV (14 women) or no HPV at all during the sampling period (5 women). Of 607 samples from 25 women, 596 were consistently positive or negative for HPV during the sampling period and 11 were inconsistent (2%). There was no difference in HPV copy number between the estrogen dominated proliferative or progesterone dominated secretory menstrual cycle phases. The major finding was a high degree of consistency concerning HR-HPV positivity and negativity of HR-HPV in vaginal fluid during a sustained period of daily self-sampling. It does not appear to matter whether the sample is collected in the proliferative or secretory phase. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Salmonella testing of pooled pre-enrichment broth cultures for screening multiple food samples.

    Science.gov (United States)

    Price, W R; Olsen, R A; Hunter, J E

    1972-04-01

    A method has been described for testing multiple food samples for Salmonella without loss in sensitivity. The method pools multiple pre-enrichment broth cultures into single enrichment broths. The subsequent stages of the Salmonella analysis are not altered. The method was found applicable to several dry food materials including nonfat dry milk, dried egg albumin, cocoa, cottonseed flour, wheat flour, and shredded coconut. As many as 25 pre-enrichment broth cultures were pooled without apparent loss in the sensitivity of Salmonella detection as compared to individual sample analysis. The procedure offers a simple, yet effective, way to increase sample capacity in the Salmonella testing of foods, particularly where a large proportion of samples ordinarily is negative. It also permits small portions of pre-enrichment broth cultures to be retained for subsequent individual analysis if positive tests are found. Salmonella testing of pooled pre-enrichment broths provides increased consumer protection for a given amount of analytical effort as compared to individual sample analysis.

  5. 'Nano-immuno test' for the detection of live Mycobacterium avium subspecies paratuberculosis bacilli in the milk samples using magnetic nano-particles and chromogen.

    Science.gov (United States)

    Singh, Manju; Singh, Shoor Vir; Gupta, Saurabh; Chaubey, Kundan Kumar; Stephan, Bjorn John; Sohal, Jagdip Singh; Dutta, Manali

    2018-04-26

    Early rapid detection of Mycobacterium avium subspecies paratuberculosis (MAP) bacilli in milk samples is the major challenge since traditional culture method is time consuming and laboratory dependent. We report a simple, sensitive and specific nano-technology based 'Nano-immuno test' capable of detecting viable MAP bacilli in the milk samples within 10 h. Viable MAP bacilli were captured by MAP specific antibody-conjugated magnetic nano-particles using resazurin dye as chromogen. Test was optimized using true culture positive (10-bovine and 12-goats) and true culture negative (16-bovine and 25-goats) raw milk samples. Domestic livestock species in India are endemically infected with MAP. After successful optimization, sensitivity and specificity of the 'nano-immuno test' in goats with respect to milk culture was 91.7% and 96.0%, respectively. Whereas, it was 90.0% (sensitivity) and 92.6% (specificity) with respect to IS900 PCR. In bovine milk samples, sensitivity and specificity of 'nano-immuno test' with respect to milk culture was 90.0% and 93.7%, respectively. However, with respect to IS900 PCR, the sensitivity and specificity was 88.9% and 94.1%, respectively. Test was validated with field raw milk samples (goats-258 and bovine-138) collected from domestic livestock species to detect live/viable MAP bacilli. Of 138 bovine raw milk samples screened by six diagnostic tests, 81 (58.7%) milk samples were positive for MAP infection in one or more than one diagnostic tests. Of 81 (58.7%) positive bovine raw milk samples, only 24 (17.4%) samples were detected positive for the presence of viable MAP bacilli. Of 258 goats raw milk samples screened by six diagnostic tests, 141 (54.6%) were positive for MAP infection in one or more than one test. Of 141 (54.6%) positive raw milk samples from goats, only 48 (34.0%) were detected positive for live MAP bacilli. Simplicity and efficiency of this novel 'nano-immuno test' makes it suitable for wide-scale screening of milk

  6. Gleeble Testing of Tungsten Samples

    Science.gov (United States)

    2013-02-01

    temperature on an Instron load frame with a 222.41 kN (50 kip) load cell . The samples were compressed at the same strain rate as on the Gleeble...ID % RE Initial Density (cm 3 ) Density after Compression (cm 3 ) % Change in Density Test Temperature NT1 0 18.08 18.27 1.06 1000 NT3 0...4.1 Nano-Tungsten The results for the compression of the nano-tungsten samples are shown in tables 2 and 3 and figure 5. During testing, sample NT1

  7. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.

    Science.gov (United States)

    Cole, Laurence A; Khanlian, Sarah A

    2004-05-01

    False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.

  8. Positive Skin Test or Specific IgE to Penicillin Does Not Reliably Predict Penicillin Allergy

    DEFF Research Database (Denmark)

    Tannert, Line Kring; Mørtz, Charlotte G; Skov, Per Stahl

    2017-01-01

    INTRODUCTION: According to guidelines, patients are diagnosed with penicillin allergy if skin test (ST) result or specific IgE (s-IgE) to penicillin is positive. However, the true sensitivity and specificity of these tests are presently not known. OBJECTIVE: To investigate the clinical relevance...... of a positive ST result and positive s-IgE and to study the reproducibility of ST and s-IgE. METHODS: A sample of convenience of 25 patients with positive penicillin ST results, antipenicillin s-IgE results, or both was challenged with their culprit penicillin. Further 19 patients were not challenged......-IgE measured (T0), and then skin tested and had s-IgE measured 4 weeks later (T1). RESULTS: Only 9 (36%) of 25 were challenge positive. There was an increased probability of being penicillin allergic if both ST result and s-IgE were positive at T0. Positive ST result or positive s-IgE alone did not predict...

  9. Cost-effectiveness of one versus two sample faecal immunochemical testing for colorectal cancer screening.

    Science.gov (United States)

    Goede, S Lucas; van Roon, Aafke H C; Reijerink, Jacqueline C I Y; van Vuuren, Anneke J; Lansdorp-Vogelaar, Iris; Habbema, J Dik F; Kuipers, Ernst J; van Leerdam, Monique E; van Ballegooijen, Marjolein

    2013-05-01

    The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if two-sample FIT screening is cost-effective compared with one-sample FIT. The MISCAN-colon microsimulation model was used to estimate costs and benefits of strategies with either one or two-sample FIT screening. The FIT cut-off level varied between 50 and 200 ng haemoglobin/ml, and the screening schedule was varied with respect to age range and interval. In addition, different definitions for positivity of the two-sample FIT were considered: at least one positive sample, two positive samples, or the mean of both samples being positive. Within an exemplary screening strategy, biennial FIT from the age of 55-75 years, one-sample FIT provided 76.0-97.0 life-years gained (LYG) per 1000 individuals, at a cost of € 259,000-264,000 (range reflects different FIT cut-off levels). Two-sample FIT screening with at least one sample being positive provided 7.3-12.4 additional LYG compared with one-sample FIT at an extra cost of € 50,000-59,000. However, when all screening intervals and age ranges were considered, intensifying screening with one-sample FIT provided equal or more LYG at lower costs compared with two-sample FIT. If attendance to screening does not differ between strategies it is recommended to increase the number of screening rounds with one-sample FIT screening, before considering increasing the number of FIT samples provided per screening round.

  10. Acceptance test procedure for core sample trucks

    International Nuclear Information System (INIS)

    Smalley, J.L.

    1995-01-01

    The purpose of this Acceptance Test Procedure is to provide instruction and documentation for acceptance testing of the rotary mode core sample trucks, HO-68K-4600 and HO-68K-4647. The rotary mode core sample trucks were based upon the design of the second core sample truck (HO-68K-4345) which was constructed to implement rotary mode sampling of the waste tanks at Hanford. Acceptance testing of the rotary mode core sample trucks will verify that the design requirements have been met. All testing will be non-radioactive and stand-in materials shall be used to simulate waste tank conditions. Compressed air will be substituted for nitrogen during the majority of testing, with nitrogen being used only for flow characterization

  11. Tests on standard concrete samples

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Compression and tensile tests on standard concrete samples. The use of centrifugal force in tensile testing has been developed by the SB Division and the instruments were built in the Central workshops.

  12. ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, T.; Hera, K.; Coleman, C.; Jones, M.; Wiedenman, B.

    2011-12-05

    the two locations were compared to determine if the contents of the tank were well mixed. The Coliwasa sampler is a tube with a stopper at the bottom and is designed to obtain grab samples from specific locations within the drum contents. A position paper (4) was issued to address the prototypic flow loop issues and simulant selections. A statistically designed plan (5) was issued to address the total number of samples each sampler needed to pull, to provide the random order in which samples were pulled and to group samples for elemental analysis. The TTR required that the Isolok sampler perform as well as the Hydragard sampler during these tests to ensure the acceptability of the Isolok sampler for use in the DWPF sampling cells. Procedure No.L9.4-5015 was used to document the sample parameters and process steps. Completed procedures are located in R&D Engineering job folder 23269.

  13. Experimental and Sampling Design for the INL-2 Sample Collection Operational Test

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Matzke, Brett D.

    2009-02-16

    This report describes the experimental and sampling design developed to assess sampling approaches and methods for detecting contamination in a building and clearing the building for use after decontamination. An Idaho National Laboratory (INL) building will be contaminated with BG (Bacillus globigii, renamed Bacillus atrophaeus), a simulant for Bacillus anthracis (BA). The contamination, sampling, decontamination, and re-sampling will occur per the experimental and sampling design. This INL-2 Sample Collection Operational Test is being planned by the Validated Sampling Plan Working Group (VSPWG). The primary objectives are: 1) Evaluate judgmental and probabilistic sampling for characterization as well as probabilistic and combined (judgment and probabilistic) sampling approaches for clearance, 2) Conduct these evaluations for gradient contamination (from low or moderate down to absent or undetectable) for different initial concentrations of the contaminant, 3) Explore judgment composite sampling approaches to reduce sample numbers, 4) Collect baseline data to serve as an indication of the actual levels of contamination in the tests. A combined judgmental and random (CJR) approach uses Bayesian methodology to combine judgmental and probabilistic samples to make clearance statements of the form "X% confidence that at least Y% of an area does not contain detectable contamination” (X%/Y% clearance statements). The INL-2 experimental design has five test events, which 1) vary the floor of the INL building on which the contaminant will be released, 2) provide for varying the amount of contaminant released to obtain desired concentration gradients, and 3) investigate overt as well as covert release of contaminants. Desirable contaminant gradients would have moderate to low concentrations of contaminant in rooms near the release point, with concentrations down to zero in other rooms. Such gradients would provide a range of contamination levels to challenge the sampling

  14. Sample Size Determination for One- and Two-Sample Trimmed Mean Tests

    Science.gov (United States)

    Luh, Wei-Ming; Olejnik, Stephen; Guo, Jiin-Huarng

    2008-01-01

    Formulas to determine the necessary sample sizes for parametric tests of group comparisons are available from several sources and appropriate when population distributions are normal. However, in the context of nonnormal population distributions, researchers recommend Yuen's trimmed mean test, but formulas to determine sample sizes have not been…

  15. The navicular position test - a reliable measure of the navicular bone position during rest and loading

    DEFF Research Database (Denmark)

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard

    2011-01-01

    .08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability...

  16. Estimating Sample Size for Usability Testing

    Directory of Open Access Journals (Sweden)

    Alex Cazañas

    2017-02-01

    Full Text Available One strategy used to assure that an interface meets user requirements is to conduct usability testing. When conducting such testing one of the unknowns is sample size. Since extensive testing is costly, minimizing the number of participants can contribute greatly to successful resource management of a project. Even though a significant number of models have been proposed to estimate sample size in usability testing, there is still not consensus on the optimal size. Several studies claim that 3 to 5 users suffice to uncover 80% of problems in a software interface. However, many other studies challenge this assertion. This study analyzed data collected from the user testing of a web application to verify the rule of thumb, commonly known as the “magic number 5”. The outcomes of the analysis showed that the 5-user rule significantly underestimates the required sample size to achieve reasonable levels of problem detection.

  17. Self-Sampling for Human Papillomavirus Testing: Increased Cervical Cancer Screening Participation and Incorporation in International Screening Programs

    Science.gov (United States)

    Gupta, Sarah; Palmer, Christina; Bik, Elisabeth M.; Cardenas, Juan P.; Nuñez, Harold; Kraal, Laurens; Bird, Sara W.; Bowers, Jennie; Smith, Alison; Walton, Nathaniel A.; Goddard, Audrey D.; Almonacid, Daniel E.; Zneimer, Susan; Richman, Jessica; Apte, Zachary S.

    2018-01-01

    In most industrialized countries, screening programs for cervical cancer have shifted from cytology (Pap smear or ThinPrep) alone on clinician-obtained samples to the addition of screening for human papillomavirus (HPV), its main causative agent. For HPV testing, self-sampling instead of clinician-sampling has proven to be equally accurate, in particular for assays that use nucleic acid amplification techniques. In addition, HPV testing of self-collected samples in combination with a follow-up Pap smear in case of a positive result is more effective in detecting precancerous lesions than a Pap smear alone. Self-sampling for HPV testing has already been adopted by some countries, while others have started trials to evaluate its incorporation into national cervical cancer screening programs. Self-sampling may result in more individuals willing to participate in cervical cancer screening, because it removes many of the barriers that prevent women, especially those in low socioeconomic and minority populations, from participating in regular screening programs. Several studies have shown that the majority of women who have been underscreened but who tested HPV-positive in a self-obtained sample will visit a clinic for follow-up diagnosis and management. In addition, a self-collected sample can also be used for vaginal microbiome analysis, which can provide additional information about HPV infection persistence as well as vaginal health in general. PMID:29686981

  18. Tests of crossed-wire position sensitive photomultipliers for scintillating fiber particle tracking

    International Nuclear Information System (INIS)

    Perdrisat, C.F.; Koechner, D.; Majewski, S.; Pourang, R.; Wilson, C.D.; Zorn, C.

    1995-01-01

    Several applications of two Hamamatsu position sensitive photomultiplier tubes to the detection of high energy particles with scintillating fibers are discussed. The PMTs are of the multiwire anode grid design, type R2486 and R4135. These tubes were tested with both single samples and arrays of 2 and 3 mm diameter scintillating fibers. Measurements of position resolution of the PMTs using either the charge digitization or the delay line readout techniques were made. The results indicate an intrinsic inability of the technique to reconstruct the actual position of a fiber on the photocathode when its location falls halfway between two grid wires. A way to overcome this limit is suggested. (orig.)

  19. Efficiency of Direct Microscopy of Stool Samples Using an Antigen-Specific Adhesin Test for Entamoeba Histolytica

    Directory of Open Access Journals (Sweden)

    Arzu İrvem

    2016-10-01

    Full Text Available Background: E. histolytica is among the common causes of acute gastroenteritis. The pathogenic species E. histolytica and the nonpathogenic species E. dispar cannot be morphologically differentiated, although correct identification of these protozoans is important for treatment and public health. In many laboratories, the screening of leukocytes, erythrocytes, amoebic cysts, trophozoites and parasite eggs is performed using Native-Lugol’s iodine for pre-diagnosis. Aims: In this study, we aimed to investigate the frequency of E. histolytica in stool samples collected from 788 patients residing in the Anatolian region of İstanbul who presented with gastrointestinal complaints. We used the information obtained to evaluate the effectiveness of microscopic examinations when used in combination with the E. histolytica adhesin antigen test. Study Design: Retrospective cross-sectional study Methods: Preparations of stool samples stained with Native-Lugol’s iodine were evaluated using the E. histolytica adhesin test and examined using standard light microscopy at ×40 magnification. Pearson’s Chi-square and Fisher’s exact tests were used for statistical analysis. Logistic regression analysis was used for multivariate analysis. Results: Of 788 samples, 38 (4.8% were positive for E. histolytica adhesin antigens. When evaluated together with the presences of erythrocytes, leukocytes, cysts, and trophozoites, respectively, using logistic regression analysis, leukocyte positivity was significantly higher. The odds ratio of leukocyte positivity increased adhesin test-positivity by 2,530-fold (95% CI=1.01–6.330. Adhesin test-positivity was significant (p=0.047. Conclusion: In line with these findings, the consistency between the presence of cysts and erythrocytes and adhesin test-positivity was found to be highly significant, but that of higher levels of leukocytes was found to be discordant. It was concluded that leukocytes and trophozoites were

  20. Malaria rapid diagnostic tests: Plasmodium falciparum infections with high parasite densities may generate false positive Plasmodium vivax pLDH lines

    Directory of Open Access Journals (Sweden)

    van Esbroeck Marjan

    2010-07-01

    Full Text Available Abstract Background Most malaria rapid diagnostic tests (RDTs detect Plasmodium falciparum and an antigen common to the four species. Plasmodium vivax-specific RDTs target P. vivax-specific parasite lactate dehydrogenase (Pv-pLDH. Previous observations of false positive Pv-pLDH test lines in P. falciparum samples incited to the present study, which assessed P. vivax-specific RDTs for the occurrence of false positive Pv-pLDH lines in P. falciparum samples. Methods Nine P. vivax-specific RDTs were tested with 85 P. falciparum samples of high (≥2% parasite density. Mixed P. falciparum/P. vivax infections were ruled out by real-time PCR. The RDTs included two-band (detecting Pv-pLDH, three-band (detecting P. falciparum-antigen and Pv-pLDH and four-band RDTs (detecting P. falciparum, Pv-pLDH and pan-pLDH. Results False positive Pv-pLDH lines were observed in 6/9 RDTs (including two- three- and four-band RDTs. They occurred in the individual RDT brands at frequencies ranging from 8.2% to 29.1%. For 19/85 samples, at least two RDT brands generated a false positive Pv-pLDH line. Sixteen of 85 (18.8% false positive lines were of medium or strong line intensity. There was no significant relation between false positive results and parasite density or geographic origin of the samples. Conclusion False positive Pv-pLDH lines in P. falciparum samples with high parasite density occurred in 6/9 P. vivax-specific RDTs. This is of concern as P. falciparum and P. vivax are co-circulating in many regions. The diagnosis of life-threatening P. falciparum malaria may be missed (two-band Pv-pLDH RDT, or the patient may be treated incorrectly with primaquine (three- or four-band RDTs.

  1. Testing a groundwater sampling tool: Are the samples representative?

    International Nuclear Information System (INIS)

    Kaback, D.S.; Bergren, C.L.; Carlson, C.A.; Carlson, C.L.

    1989-01-01

    A ground water sampling tool, the HydroPunch trademark, was tested at the Department of Energy's Savannah River Site in South Carolina to determine if representative ground water samples could be obtained without installing monitoring wells. Chemical analyses of ground water samples collected with the HydroPunch trademark from various depths within a borehole were compared with chemical analyses of ground water from nearby monitoring wells. The site selected for the test was in the vicinity of a large coal storage pile and a coal pile runoff basin that was constructed to collect the runoff from the coal storage pile. Existing monitoring wells in the area indicate the presence of a ground water contaminant plume that: (1) contains elevated concentrations of trace metals; (2) has an extremely low pH; and (3) contains elevated concentrations of major cations and anions. Ground water samples collected with the HydroPunch trademark provide in excellent estimate of ground water quality at discrete depths. Groundwater chemical data collected from various depths using the HydroPunch trademark can be averaged to simulate what a screen zone in a monitoring well would sample. The averaged depth-discrete data compared favorably with the data obtained from the nearby monitoring wells

  2. Prevailence of Patch Test Positivity with Some Bases

    Directory of Open Access Journals (Sweden)

    J S Pasricha

    1987-01-01

    Full Text Available To evaluate the suitability of some chemicals to act as bases for antigens for patch tests, patch tests were performed with these agents in patients having contact dermatitis. Propylene glycol′used as such produced positive reactions in 25 (50% patients of which 12 were 2 + or more, polyethylene glycol 200 produced positive reactions in 9 (18% cases of which 4 cases were 2 + or more, a mixture of liquid paraffin and hard paraffin gave rise to positive reactions in 10 (10% cases 3 of these being 2 +, a mixture of liquid paraffin and bees wax was positive in 14 (14,Yo cases 3 of these being 2 +, yellow petrolatum was positive in 4 (8% cases, one of which was 2 +, white petrolatum was positive in S (6% cases all of these being + reactions only, and glycerol gave rise to a I + reaction in only one (2% caw. In tropical countries, water should be as base for as many antigens as possible for others, a control test with the b must be included.

  3. Identification and characterization of microsporidia from fecal samples of HIV-positive patients from Lagos, Nigeria.

    Directory of Open Access Journals (Sweden)

    Oladele Teslim Ojuromi

    Full Text Available BACKGROUND: Microsporidia are obligate intracellular parasites that infect a broad range of vertebrates and invertebrates. They have been increasingly recognized as human pathogens in AIDS patients, mainly associated with a life-threatening chronic diarrhea and systemic disease. However, to date the global epidemiology of human microsporidiosis is poorly understood, and recent data suggest that the incidence of these pathogens is much higher than previously reported and may represent a neglected etiological agent of more common diseases indeed in immunocompetent individuals. To contribute to the knowledge of microsporidia molecular epidemiology in HIV-positive patients in Nigeria, the authors tested stool samples proceeding from patients with and without diarrhea. METHODOLOGY/PRINCIPAL FINDINGS: Stool samples from 193 HIV-positive patients with and without diarrhea (67 and 126 respectively from Lagos (Nigeria were investigated for the presence of microsporidia and Cryptosporidium using Weber's Chromotrope-based stain, Kinyoun stain, IFAT and PCR. The Weber stain showed 45 fecal samples (23.3% with characteristic microsporidia spores, and a significant association of microsporidia with diarrhea was observed (O.R. = 18.2; CI: 95%. A similar result was obtained using Kinyoun stain, showing 44 (31,8% positive samples with structures morphologically compatible with Cryptosporidium sp, 14 (31.8% of them with infection mixed with microsporidia. The characterization of microsporidia species by IFAT and PCR allowed identification of Enterocytozoon bieneusi, Encephalitozoon intestinalis and E. cuniculi in 5, 2 and 1 samples respectively. The partial sequencing of the ITS region of the rRNA genes showed that the three isolates of E.bieneusi studied are included in Group I, one of which bears the genotype B. CONCLUSIONS/SIGNIFICANCE: To our knowledge, this is the first report of microsporidia characterization in fecal samples from HIV-positive patients from

  4. Reactivation of tuberculosis during immunosuppressive treatment in a patient with a positive QuantiFERON-RD1 test

    DEFF Research Database (Denmark)

    Ravn, Pernille; Munk, Martin E; Andersen, Ase Bengaard

    2004-01-01

    A patient with polymyositis developed tuberculosis during immunosuppressive treatment. Tuberculin Skin Test and chest X-ray failed to demonstrate latent tuberculosis, whereas a blood sample that was tested with a modified QuantiFERON-TB-assay, using the recombinant ESAT-6 and CFP-10, was positive...

  5. Benefits of expressive writing in reducing test anxiety: A randomized controlled trial in Chinese samples.

    Science.gov (United States)

    Shen, Lujun; Yang, Lei; Zhang, Jing; Zhang, Meng

    2018-01-01

    To explore the effect of expressive writing of positive emotions on test anxiety among senior-high-school students. The Test Anxiety Scale (TAS) was used to assess the anxiety level of 200 senior-high-school students. Seventy-five students with high anxiety were recruited and divided randomly into experimental and control groups. Each day for 30 days, the experimental group engaged in 20 minutes of expressive writing of positive emotions, while the control group was asked to merely write down their daily events. A second test was given after the month-long experiment to analyze whether there had been a reduction in anxiety among the sample. Quantitative data was obtained from TAS scores. The NVivo10.0 software program was used to examine the frequency of particular word categories used in participants' writing manuscripts. Senior-high-school students indicated moderate to high test anxiety. There was a significant difference in post-test results (P 0.05). Students' writing manuscripts were mainly encoded on five code categories: cause, anxiety manifestation, positive emotion, insight and evaluation. There was a negative relation between positive emotion, insight codes and test anxiety. There were significant differences in the positive emotion, anxiety manifestation, and insight code categories between the first 10 days' manuscripts and the last 10 days' ones. Long-term expressive writing of positive emotions appears to help reduce test anxiety by using insight and positive emotion words for Chinese students. Efficient and effective intervention programs to ease test anxiety can be designed based on this study.

  6. Benefits of expressive writing in reducing test anxiety: A randomized controlled trial in Chinese samples.

    Directory of Open Access Journals (Sweden)

    Lujun Shen

    Full Text Available To explore the effect of expressive writing of positive emotions on test anxiety among senior-high-school students.The Test Anxiety Scale (TAS was used to assess the anxiety level of 200 senior-high-school students. Seventy-five students with high anxiety were recruited and divided randomly into experimental and control groups. Each day for 30 days, the experimental group engaged in 20 minutes of expressive writing of positive emotions, while the control group was asked to merely write down their daily events. A second test was given after the month-long experiment to analyze whether there had been a reduction in anxiety among the sample. Quantitative data was obtained from TAS scores. The NVivo10.0 software program was used to examine the frequency of particular word categories used in participants' writing manuscripts.Senior-high-school students indicated moderate to high test anxiety. There was a significant difference in post-test results (P 0.05. Students' writing manuscripts were mainly encoded on five code categories: cause, anxiety manifestation, positive emotion, insight and evaluation. There was a negative relation between positive emotion, insight codes and test anxiety. There were significant differences in the positive emotion, anxiety manifestation, and insight code categories between the first 10 days' manuscripts and the last 10 days' ones.Long-term expressive writing of positive emotions appears to help reduce test anxiety by using insight and positive emotion words for Chinese students. Efficient and effective intervention programs to ease test anxiety can be designed based on this study.

  7. Benefits of expressive writing in reducing test anxiety: A randomized controlled trial in Chinese samples

    Science.gov (United States)

    Zhang, Jing; Zhang, Meng

    2018-01-01

    Purpose To explore the effect of expressive writing of positive emotions on test anxiety among senior-high-school students. Methods The Test Anxiety Scale (TAS) was used to assess the anxiety level of 200 senior-high-school students. Seventy-five students with high anxiety were recruited and divided randomly into experimental and control groups. Each day for 30 days, the experimental group engaged in 20 minutes of expressive writing of positive emotions, while the control group was asked to merely write down their daily events. A second test was given after the month-long experiment to analyze whether there had been a reduction in anxiety among the sample. Quantitative data was obtained from TAS scores. The NVivo10.0 software program was used to examine the frequency of particular word categories used in participants’ writing manuscripts. Results Senior-high-school students indicated moderate to high test anxiety. There was a significant difference in post-test results (P 0.05). Students’ writing manuscripts were mainly encoded on five code categories: cause, anxiety manifestation, positive emotion, insight and evaluation. There was a negative relation between positive emotion, insight codes and test anxiety. There were significant differences in the positive emotion, anxiety manifestation, and insight code categories between the first 10 days’ manuscripts and the last 10 days’ ones. Conclusions Long-term expressive writing of positive emotions appears to help reduce test anxiety by using insight and positive emotion words for Chinese students. Efficient and effective intervention programs to ease test anxiety can be designed based on this study. PMID:29401473

  8. Frictional sliding tests on combined coal-rock samples

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2014-06-01

    Full Text Available A test system was developed to understand the sliding mechanism of coal-rock structure. The test system was composed by a double-shear testing model and an acousto-optic monitoring system in association with a digital camera and an acoustic emission (AE instrument. The tests can simulate the movement of activated faults and the sliding in coal-rock structure. In this regard, instable sliding conditions of coal-rock samples, sliding types under different conditions, displacement evolution law, and AE characteristics during sliding process were investigated. Several sliding types were monitored in the tests, including unstable continuous sliding, unstable discontinuous sliding, and stable sliding. The sliding types have close relation with the axial loads and loading rates. Larger axial load and smaller loading rate mean that unstable sliding is less likely to occur. The peak shear stress was positively correlated with the axial load when sliding occurred, whereas the displacement induced by unstable sliding was uncorrelated with the axial load. A large number of AE events occurred before sliding, and the AE rate decreased after stable sliding. The results show that the tests can well simulate the process of structural instability in a coal bump, and are helpful in the understanding of fault activation and the physical processes during squeezing process of roof and floor.

  9. Yersinia enterocolitica: an unlikely cause of positive brucellosis tests in greater yellowstone ecosystem bison (Bison bison).

    Science.gov (United States)

    See, Wade; Edwards, William H; Dauwalter, Stacey; Almendra, Claudia; Kardos, Martin D; Lowell, Jennifer L; Wallen, Rick; Cain, Steven L; Holben, William E; Luikart, Gordon

    2012-07-01

    Yersinia enterocolitica serotype O:9 has identical O-antigens to those of Brucella abortus and has apparently caused false-positive reactions in numerous brucellosis serologic tests in elk (Cervus canadensis) from southwest Montana. We investigated whether a similar phenomenon was occurring in brucellosis antibody-positive bison (Bison bison) using Y. enterocolitica culturing techniques and multiplex PCR of four diagnostic loci. Feces from 53 Yellowstone bison culled from the population and 113 free-roaming bison from throughout the Greater Yellowstone Ecosystem (GYE) were tested. Yersinia enterocolitica O:9 was not detected in any of 53 the bison samples collected at slaughter facilities or in any of the 113 fecal samples from free-ranging bison. One other Y. enterocolitica serotype was isolated; however, it is not known to cause cross-reaction on B. abortus serologic assays because it lacks the perosamine synthetase gene and thus the O-antigens. These findings suggest that Y. enterocolitica O:9 cross-reactivity with B. abortus antigens is unlikely to have been a cause of false-positive serology tests in GYE bison and that Y. enterocolitica prevalence was low in bison in the GYE during this study.

  10. Is a positive intracutaneous test induced by penicillin mediated by histamine?

    DEFF Research Database (Denmark)

    Tannert, Line K; Falkencrone, Sidsel; Mortz, Charlotte G

    2017-01-01

    Background: Diagnostic workup of penicillin allergy comprises skin testing with penicillins, and patients are deemed allergic if skin test is positive. However, the literature suggests that skin test-positive patients may be challenge-negative, indicating that the skin test may be falsely positive....... Objective: To investigate real-time histamine release from a positive intracutaneous test induced by penicillin in patients with positive and negative challenges to penicillin. Methods: Skin microdialysis was performed in 21 penicillin-allergic patients with positive skin test, 13 non-allergic volunteers...... serving as negative controls, and 7 grass pollen-allergic patients serving as positive controls. Histamine was measured by microdialysis after skin test with penicillin/grass/NaCl. Penicillin challenge was subsequently performed in 12 of the patients. Results: Only 10/21 patients (47.6%) were skin test...

  11. Testing HIV positive in pregnancy: A phenomenological study of women's experiences.

    Science.gov (United States)

    Lingen-Stallard, Andrew; Furber, Christine; Lavender, Tina

    2016-04-01

    globally women receive HIV testing in pregnancy; however, limited information is available on their experiences of this potentially life-changing event. This study aims to explore women's experiences of receiving a positive HIV test result following antenatal screening. a qualitative, phenomenological approach. two public National Health Service (NHS) hospitals and HIV support organisations. a purposive sampling strategy was used. Thirteen black African women with a positive HIV result, in England, participated. data were collected using in-depth semi-structured interviews. An interpretive phenomenological approach to data analysis was used. the emergent phenomenon was transition and transformation of 'being,' as women accepted HIV as part of their lives. Paired themes support the phenomenon: shock and disbelief; anger and turmoil; stigma and confidentiality issues; acceptance and resilience. Women had extreme reactions to their positive HIV diagnosis, compounded by the cultural belief that they would die. Initial disbelief of the unexpected result developed into sadness at the loss of their old self. Turmoil was evident, as women considered termination of pregnancy, self-harm and suicide. Women felt isolated from others and relationship breakdowns often occurred. Most reported the pervasiveness of stigma, and how this was managed alongside living with HIV. Coping strategies included keeping HIV 'secret' and making their child(ren) the prime focus of life. Growing resilience was apparent with time. this study gives midwives unique understanding of the complexities and major implications for women who tested positive for HIV. Women's experiences resonated with processes of bereavement, providing useful insight into a transitional and transformational period, during which appropriate support can be targeted. midwives are crucial in improving the experience of women when they test HIV positive and to do this they need to be appropriately trained. Midwives need to

  12. 'False-positive' and 'false-negative' test results in clinical urine drug testing.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2009-08-01

    The terms 'false-positive' and 'false-negative' are widely used in discussions of urine drug test (UDT) results. These terms are inadequate because they are used in different ways by physicians and laboratory professionals and they are too narrow to encompass the larger universe of potentially misleading, inappropriate and unexpected drug test results. This larger universe, while not solely comprised of technically 'true' or 'false' positive or negative test results, presents comparable interpretive challenges with corresponding clinical implications. In this review, we propose the terms 'potentially inappropriate' positive or negative test results in reference to UDT results that are ambiguous or unexpected and subject to misinterpretation. Causes of potentially inappropriate positive UDT results include in vivo metabolic conversions of a drug, exposure to nonillicit sources of a drug and laboratory error. Causes of potentially inappropriate negative UDT results include limited assay specificity, absence of drug in the urine, presence of drug in the urine, but below established assay cutoff, specimen manipulation and laboratory error. Clinical UDT interpretation is a complicated task requiring knowledge of recent prescription, over-the-counter and herbal drug administration, drug metabolism and analytical sensitivities and specificities.

  13. A novel approach for small sample size family-based association studies: sequential tests.

    Science.gov (United States)

    Ilk, Ozlem; Rajabli, Farid; Dungul, Dilay Ciglidag; Ozdag, Hilal; Ilk, Hakki Gokhan

    2011-08-01

    In this paper, we propose a sequential probability ratio test (SPRT) to overcome the problem of limited samples in studies related to complex genetic diseases. The results of this novel approach are compared with the ones obtained from the traditional transmission disequilibrium test (TDT) on simulated data. Although TDT classifies single-nucleotide polymorphisms (SNPs) to only two groups (SNPs associated with the disease and the others), SPRT has the flexibility of assigning SNPs to a third group, that is, those for which we do not have enough evidence and should keep sampling. It is shown that SPRT results in smaller ratios of false positives and negatives, as well as better accuracy and sensitivity values for classifying SNPs when compared with TDT. By using SPRT, data with small sample size become usable for an accurate association analysis.

  14. Effect of days in milk and milk yield on testing positive in milk antibody ELISA to Mycobacterium avium subsp. paratuberculosis in dairy cattle

    DEFF Research Database (Denmark)

    Nielsen, Søren Saxmose; Toft, Nils

    2012-01-01

    Milk samples are becoming more used as a diagnostic specimen for assessment of occurrence of antibodies to Mycobacterium avium subsp. paratuberculosis (MAP). This study assessed the effect of days in milk (DIM) and milk yield on testing positive in a commercial MAP specific milk antibody ELISA...... from the first couple of DIM should be excluded from MAP testing until further information on their significance is established. Milk yield also had a significant effect on odds of testing positive due to its diluting effect. Inclusion of milk yield in the interpretation of test results could improve...... among 222,774 Danish Holstein cows. Results showed that odds of testing positive on 1-2 DIM were 9-27 times higher than the rest of lactation, where the chance of testing positive varied less. The reason is most likely a high concentration of non-specific antibodies in colostrum. Consequently, samples...

  15. 7 CFR 28.952 - Testing of samples.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Testing of samples. 28.952 Section 28.952 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... processing tests of the properties of cotton samples and report the results thereof to the persons from whom...

  16. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  17. Airflow Test of Acoustic Board Samples

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Jensen, Lise Mellergaard

    In the laboratory of Indoor Environmental Engineering, Department of Civil Engineering, Aalborg University an airflow test on 2x10 samples of acoustic board were carried out the 2nd of June 2012. The tests were carried out for Rambøll and STO AG. The test includes connected values of volume flow...

  18. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Science.gov (United States)

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  19. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Directory of Open Access Journals (Sweden)

    Leslie Shanks

    Full Text Available Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals.Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367 in the VL group compared to 7.9% (200/2526 in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively.The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  20. The positive and negative consequences of multiple-choice testing.

    Science.gov (United States)

    Roediger, Henry L; Marsh, Elizabeth J

    2005-09-01

    Multiple-choice tests are commonly used in educational settings but with unknown effects on students' knowledge. The authors examined the consequences of taking a multiple-choice test on a later general knowledge test in which students were warned not to guess. A large positive testing effect was obtained: Prior testing of facts aided final cued-recall performance. However, prior testing also had negative consequences. Prior reading of a greater number of multiple-choice lures decreased the positive testing effect and increased production of multiple-choice lures as incorrect answers on the final test. Multiple-choice testing may inadvertently lead to the creation of false knowledge.

  1. Single-position Hall effect measurements

    DEFF Research Database (Denmark)

    2014-01-01

    A method for determining a distance (Y) between a first position on and an electrical boundary (34) of a test sample by a multi-point probe comprising four contact elements, comprising: contacting the test sample with the four contact elements (20,22,24,26) at the first position, applying a magne...

  2. The impact of induced positive mood on symptomatic behaviour in eating disorders. An experimental, AB/BA crossover design testing a multimodal presentation during a test-meal.

    Science.gov (United States)

    Cardi, Valentina; Esposito, Mirko; Clarke, Ariana; Schifano, Sylvia; Treasure, Janet

    2015-04-01

    The aim of this study was to test the impact of a multimodal positive mood vodcast including pleasant images, background uplifting music and a script designed to elicit positive mood on eating disorders-related symptoms in participants suffering from an Eating Disorder (ED) and healthy controls (HCs). Forty-two women with an ED (Anorexia Nervosa [AN]: N = 19; Bulimia Nervosa [BN]: N = 23) and 36 HCs were included in an AB/BA cross-over design which compared the use of a positive mood induction procedure ("positive mood vodcast") with a control condition (i.e. blue static background, neutral music, and script describing objective facts) during a test-meal. Self-report measures and behavioural tasks were completed before and after the test-meal. The positive mood vodcast was associated with greater consumption of the test meal in the AN group; reduced vigilance to food stimuli and lower anxiety in the BN sample; and no significant changes in the HC group. The use of a positive mood vodcast was associated with some beneficial effects in the context of an experimental test-meal in participants with an ED. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. 46 CFR 160.050-5 - Sampling, tests, and inspection.

    Science.gov (United States)

    2010-10-01

    ... one from which any sample ring life buoy failed the buoyancy or strength test, the sample shall... ring life buoys with this subpart. The manufacturer shall provide means to secure any test that is not... procedures. Table 160.050-5(e)—Sampling for Buoyancy Tests Lot size Number of life buoys in sample 100 and...

  4. Evaluation of HIV testing algorithms in Ethiopia: the role of the tie-breaker algorithm and weakly reacting test lines in contributing to a high rate of false positive HIV diagnoses.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Pirou, Erwan; Ritmeijer, Koert; Masiga, Johnson; Abebe, Almaz

    2015-02-03

    In Ethiopia a tiebreaker algorithm using 3 rapid diagnostic tests (RDTs) in series is used to diagnose HIV. Discordant results between the first 2 RDTs are resolved by a third 'tiebreaker' RDT. Médecins Sans Frontières uses an alternate serial algorithm of 2 RDTs followed by a confirmation test for all double positive RDT results. The primary objective was to compare the performance of the tiebreaker algorithm with a serial algorithm, and to evaluate the addition of a confirmation test to both algorithms. A secondary objective looked at the positive predictive value (PPV) of weakly reactive test lines. The study was conducted in two HIV testing sites in Ethiopia. Study participants were recruited sequentially until 200 positive samples were reached. Each sample was re-tested in the laboratory on the 3 RDTs and on a simple to use confirmation test, the Orgenics Immunocomb Combfirm® (OIC). The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. 2620 subjects were included with a HIV prevalence of 7.7%. Each of the 3 RDTs had an individual specificity of at least 99%. The serial algorithm with 2 RDTs had a single false positive result (1 out of 204) to give a PPV of 99.5% (95% CI 97.3%-100%). The tiebreaker algorithm resulted in 16 false positive results (PPV 92.7%, 95% CI: 88.4%-95.8%). Adding the OIC confirmation test to either algorithm eliminated the false positives. All the false positives had at least one weakly reactive test line in the algorithm. The PPV of weakly reacting RDTs was significantly lower than those with strongly positive test lines. The risk of false positive HIV diagnosis in a tiebreaker algorithm is significant. We recommend abandoning the tie-breaker algorithm in favour of WHO recommended serial or parallel algorithms, interpreting weakly reactive test lines as indeterminate results requiring further testing except in the setting of blood transfusion, and most importantly, adding a confirmation test

  5. Sample positioning in neutron diffraction experiments using a multi-material fiducial marker

    Energy Technology Data Exchange (ETDEWEB)

    Marais, D., E-mail: Deon.Marais@necsa.co.za [Research and Development Division, South African Nuclear Energy Corporation (Necsa) SOC Limited, PO Box 582, Pretoria 0001 (South Africa); School of Mechanical and Nuclear Engineering, North-West University, Potchefstroom 2520 (South Africa); Venter, A.M., E-mail: Andrew.Venter@necsa.co.za [Research and Development Division, South African Nuclear Energy Corporation (Necsa) SOC Limited, PO Box 582, Pretoria 0001 (South Africa); Faculty of Agriculture Science and Technology, North-West University, Mahikeng 2790 (South Africa); Markgraaff, J., E-mail: Johan.Markgraaff@nwu.ac.za [School of Mechanical and Nuclear Engineering, North-West University, Potchefstroom 2520 (South Africa); James, J., E-mail: Jon.James@open.ac.uk [Faculty of Mathematics, Computing and Technology, The Open University, Milton Keynes, MK76AA England (United Kingdom)

    2017-01-01

    An alternative sample positioning method is reported for use in conjunction with sample positioning and experiment planning software systems deployed on some neutron diffraction strain scanners. In this approach, the spherical fiducial markers and location trackers used with optical metrology hardware are replaced with a specifically designed multi-material fiducial marker that requires one diffraction measurement. In a blind setting, the marker position can be determined within an accuracy of ±164 µm with respect to the instrument gauge volume. The scheme is based on a pre-determined relationship that links the diffracted peak intensity to the absolute positioning of the fiducial marker with respect to the instrument gauge volume. Two methods for establishing the linking relationship are presented, respectively based on fitting multi-dimensional quadratic functions and a cross-correlation artificial neural network.

  6. Gram-negative and -positive bacteria differentiation in blood culture samples by headspace volatile compound analysis.

    Science.gov (United States)

    Dolch, Michael E; Janitza, Silke; Boulesteix, Anne-Laure; Graßmann-Lichtenauer, Carola; Praun, Siegfried; Denzer, Wolfgang; Schelling, Gustav; Schubert, Sören

    2016-12-01

    Identification of microorganisms in positive blood cultures still relies on standard techniques such as Gram staining followed by culturing with definite microorganism identification. Alternatively, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or the analysis of headspace volatile compound (VC) composition produced by cultures can help to differentiate between microorganisms under experimental conditions. This study assessed the efficacy of volatile compound based microorganism differentiation into Gram-negatives and -positives in unselected positive blood culture samples from patients. Headspace gas samples of positive blood culture samples were transferred to sterilized, sealed, and evacuated 20 ml glass vials and stored at -30 °C until batch analysis. Headspace gas VC content analysis was carried out via an auto sampler connected to an ion-molecule reaction mass spectrometer (IMR-MS). Measurements covered a mass range from 16 to 135 u including CO2, H2, N2, and O2. Prediction rules for microorganism identification based on VC composition were derived using a training data set and evaluated using a validation data set within a random split validation procedure. One-hundred-fifty-two aerobic samples growing 27 Gram-negatives, 106 Gram-positives, and 19 fungi and 130 anaerobic samples growing 37 Gram-negatives, 91 Gram-positives, and two fungi were analysed. In anaerobic samples, ten discriminators were identified by the random forest method allowing for bacteria differentiation into Gram-negative and -positive (error rate: 16.7 % in validation data set). For aerobic samples the error rate was not better than random. In anaerobic blood culture samples of patients IMR-MS based headspace VC composition analysis facilitates bacteria differentiation into Gram-negative and -positive.

  7. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    Science.gov (United States)

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (preinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  8. Operability test procedure for PFP wastewater sampling facility

    International Nuclear Information System (INIS)

    Hirzel, D.R.

    1995-01-01

    Document provides instructions for performing the Operability Test of the 225-WC Wastewater Sampling Station which monitors the discharge to the Treated Effluent Disposal Facility from the Plutonium Finishing Plant. This Operability Test Procedure (OTP) has been prepared to verify correct configuration and performance of the PFP Wastewater sampling system installed in Building 225-WC located outside the perimeter fence southeast of the Plutonium Finishing Plant (PFP). The objective of this test is to ensure the equipment in the sampling facility operates in a safe and reliable manner. The sampler consists of two Manning Model S-5000 units which are rate controlled by the Milltronics Ultrasonic flowmeter at manhole No.C4 and from a pH measuring system with the sensor in the stream adjacent to the sample point. The intent of the dual sampling system is to utilize one unit to sample continuously at a rate proportional to the wastewater flow rate so that the aggregate tests are related to the overall flow and thereby eliminate isolated analyses. The second unit will only operate during a high or low pH excursion of the stream (hence the need for a pH control). The major items in this OTP include testing of the Manning Sampler System and associated equipment including the pH measuring and control system, the conductivity monitor, and the flow meter

  9. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF.

    Science.gov (United States)

    Tanner, Hannah; Evans, Jason T; Gossain, Savita; Hussain, Abid

    2017-01-18

    Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) were applied to each positive culture followed by centrifugation, washing and protein extraction steps. Methods were compared using the McNemar test and 16S rDNA sequencing was used to assess discordant results. In 144 monomicrobial cultures, using ≥2.000 as the cut-off value, species level identifications were obtained from 69/144 (48%) samples using Saponin, 86/144 (60%) using SDS, and 91/144 (63%) using SepsiTyper. The difference between SDS and SepsiTyper was not statistically significant (P = 0.228). Differences between Saponin and the other two reagents were significant (P direct MALDI-TOF identification were observed in monomicrobial cultures. In 32 polymicrobial cultures, MALDI-TOF identified one organism in 34-75% of samples depending on the method. This study demonstrates two inexpensive in-house detergent lysis methods are non-inferior to a commercial kit for analysis of positive blood cultures by direct MALDI-TOF in a clinical diagnostic microbiology laboratory.

  10. Mixing and sampling tests for Radiochemical Plant

    International Nuclear Information System (INIS)

    Ehinger, M.N.; Marfin, H.R.; Hunt, B.

    1999-01-01

    The paper describes results and test procedures used to evaluate uncertainly and basis effects introduced by the sampler systems of a radiochemical plant, and similar parameters associated with mixing. This report will concentrate on experiences at the Barnwell Nuclear Fuels Plant. Mixing and sampling tests can be conducted to establish the statistical parameters for those activities related to overall measurement uncertainties. Density measurements by state-of-the art, commercially availability equipment is the key to conducting those tests. Experience in the U.S. suggests the statistical contribution of mixing and sampling can be controlled to less than 0.01 % and with new equipment and new tests in operating facilities might be controlled to better accuracy [ru

  11. 40 CFR 205.171-3 - Test motorcycle sample selection.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test motorcycle sample selection. 205... ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Motorcycle Exhaust Systems § 205.171-3 Test motorcycle sample selection. A test motorcycle to be used for selective enforcement audit testing...

  12. Test plan for core sampling drill bit temperature monitor

    International Nuclear Information System (INIS)

    Francis, P.M.

    1994-01-01

    At WHC, one of the functions of the Tank Waste Remediation System division is sampling waste tanks to characterize their contents. The push-mode core sampling truck is currently used to take samples of liquid and sludge. Sampling of tanks containing hard salt cake is to be performed with the rotary-mode core sampling system, consisting of the core sample truck, mobile exhauster unit, and ancillary subsystems. When drilling through the salt cake material, friction and heat can be generated in the drill bit. Based upon tank safety reviews, it has been determined that the drill bit temperature must not exceed 180 C, due to the potential reactivity of tank contents at this temperature. Consequently, a drill bit temperature limit of 150 C was established for operation of the core sample truck to have an adequate margin of safety. Unpredictable factors, such as localized heating, cause this buffer to be so great. The most desirable safeguard against exceeding this threshold is bit temperature monitoring . This document describes the recommended plan for testing the prototype of a drill bit temperature monitor developed for core sampling by Sandia National Labs. The device will be tested at their facilities. This test plan documents the tests that Westinghouse Hanford Company considers necessary for effective testing of the system

  13. Research of built-in self test technology on cable-free self-positioning seismograph

    Science.gov (United States)

    Huaizhu, Z.; Lin, J.; Chen, Z.; Zhang, L.; Yang, H.; Zheng, F.

    2011-12-01

    Cable-free self-positioning seismograph is the key instrument and equipment required for deep seismic exploration in China. In order to measure the performance of seismic data acquisition systems whether meet exploration requirements , to ensure the accuracy of seismic data, and to ensure equipment reliability and stability, a built-in self test solution of the cable-free self-positioning seismic recorder is provided. Within a 24-bits Σ-Δ DAC, the seismograph can produce sine, step, pulse and other high-precision analog test signal, with dynamic range of 120dB or more, through the FPGA to control the analog multiplexer switching the input signal acquisition channels, and start the 24-bit Σ-Δ ADC in the instrument internal simultaneously to acquisition the test signal data, carries on the fast Fournier transformation by instrument internal CPU, to achieve the instrument of analysis and calculation of performance indicators, including: the equivalent noise and drift, common mode rejection ratio (CMRR), crosstalk, harmonic distortion, dynamic range, channel response consistency, detector impulse response , etc. A lot of testing experiments about the various parameters were performed and studied currently. By setting different sampling rate (1Hz, 5Hz, ..., 4kHz), each of the measurement system noise level was measured, and the maximum noise is about 0.5μV; the crosstalk between channels was tested using the 31.25Hz sine wave, the result is more than-120dB with sampling rate of 1kHz; the harmonic distortion was measured by adding the high-precision sine wave signals of different frequencies, such as 500Hz, 250 Hz, 125 Hz, 62.5 Hz, 31.25 Hz, 15.625 Hz, 7.812 Hz, 3.90625Hz, etc. the calculated results is in-118dB or more. The experimental results show that, the parameters of the cable-free self-positioning of the seismic recorder meet the technical requirements for the deep exploration, compared to the corresponding parameters with the 428XL seismograph of the French

  14. Estimation of sample size and testing power (part 5).

    Science.gov (United States)

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2012-02-01

    Estimation of sample size and testing power is an important component of research design. This article introduced methods for sample size and testing power estimation of difference test for quantitative and qualitative data with the single-group design, the paired design or the crossover design. To be specific, this article introduced formulas for sample size and testing power estimation of difference test for quantitative and qualitative data with the above three designs, the realization based on the formulas and the POWER procedure of SAS software and elaborated it with examples, which will benefit researchers for implementing the repetition principle.

  15. Relevance of positive patch-test reactions to fragrance mix.

    Science.gov (United States)

    Devos, Steven A; Constandt, Lieve; Tupker, Ron A; Noz, Kathy C; Lucker, Georges P H; Bruynzeel, Derk P; Schuttelaar, Marie-Louise A; Kruyswijk, Mente R J; van Zuuren, Esther J; Vink, Jaqueline; Coenraads, Pieter-Jan; Kiemeney, Lambertus A L M; van der Valk, Pieter G M

    2008-01-01

    Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong reactions. To improve the appraisal of FM patch-test reactions, we studied the relevance of reactions of different strength. We also studied the predictive value of the following on the relevance of the initial FM patch-test results: patch-test results of a repeated FM test; results of patch tests with balsam of Peru, colophony, and ingredients of the mix; and (history of) atopic dermatitis. One hundred thirty-eight patients who had doubtful positive (?+) or positive (+ to +++) reactions were included in the study. We determined relevance by history taking, location and course of the dermatitis, and additional patch testing. Patients were retested with FM and with each ingredient separately. The relevance of reactions to FM increases with the strength of the reactions. Predictors of relevance are the results of retesting with FM, the results of tests with the ingredients, and a history and/or present symptoms of atopic dermatitis. Retesting with FM and its ingredients may add to the benefit of patch testing.

  16. Increased risk of breast cancer in women with false-positive test

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Kuchiki, Megumi; Vejborg, Ilse

    2014-01-01

    of misclassification, i.e. women who were actually false-negatives instead of false-positives. METHOD: We used data from the Copenhagen Mammography Screening Programme, Denmark. The study population was the 295 women, out of 4743 recalled women from a total of 58,003 participants, with a false-positive test during...... the women with misclassified tests had been excluded, there was an excess risk of breast cancer of 27% (RR=1.27, 95% confidence interval (CI), 1.11-1.46) among the women with a false-positive test compared to women with only negative tests. Women with a false-positive test determined at assessment had...... an excess risk of 27%, while false-positives determined at surgery had an excess risk of 30%. CONCLUSIONS: The results indicate that the increased risk is not explained only by misclassification. The excess risk remains for false-positives determined at assessment as well as at surgery, which favours some...

  17. Testing of Small Graphite Samples for Nuclear Qualification

    Energy Technology Data Exchange (ETDEWEB)

    Julie Chapman

    2010-11-01

    Accurately determining the mechanical properties of small irradiated samples is crucial to predicting the behavior of the overal irradiated graphite components within a Very High Temperature Reactor. The sample size allowed in a material test reactor, however, is limited, and this poses some difficulties with respect to mechanical testing. In the case of graphite with a larger grain size, a small sample may exhibit characteristics not representative of the bulk material, leading to inaccuracies in the data. A study to determine a potential size effect on the tensile strength was pursued under the Next Generation Nuclear Plant program. It focuses first on optimizing the tensile testing procedure identified in the American Society for Testing and Materials (ASTM) Standard C 781-08. Once the testing procedure was verified, a size effect was assessed by gradually reducing the diameter of the specimens. By monitoring the material response, a size effect was successfully identified.

  18. Sample size calculations based on a difference in medians for positively skewed outcomes in health care studies

    Directory of Open Access Journals (Sweden)

    Aidan G. O’Keeffe

    2017-12-01

    Full Text Available Abstract Background In healthcare research, outcomes with skewed probability distributions are common. Sample size calculations for such outcomes are typically based on estimates on a transformed scale (e.g. log which may sometimes be difficult to obtain. In contrast, estimates of median and variance on the untransformed scale are generally easier to pre-specify. The aim of this paper is to describe how to calculate a sample size for a two group comparison of interest based on median and untransformed variance estimates for log-normal outcome data. Methods A log-normal distribution for outcome data is assumed and a sample size calculation approach for a two-sample t-test that compares log-transformed outcome data is demonstrated where the change of interest is specified as difference in median values on the untransformed scale. A simulation study is used to compare the method with a non-parametric alternative (Mann-Whitney U test in a variety of scenarios and the method is applied to a real example in neurosurgery. Results The method attained a nominal power value in simulation studies and was favourable in comparison to a Mann-Whitney U test and a two-sample t-test of untransformed outcomes. In addition, the method can be adjusted and used in some situations where the outcome distribution is not strictly log-normal. Conclusions We recommend the use of this sample size calculation approach for outcome data that are expected to be positively skewed and where a two group comparison on a log-transformed scale is planned. An advantage of this method over usual calculations based on estimates on the log-transformed scale is that it allows clinical efficacy to be specified as a difference in medians and requires a variance estimate on the untransformed scale. Such estimates are often easier to obtain and more interpretable than those for log-transformed outcomes.

  19. Self-sampling for human papillomavirus testing among rural young women of KwaZulu-Natal, South Africa.

    Science.gov (United States)

    Mbatha, J N; Galappaththi-Arachchige, H N; Mtshali, A; Taylor, M; Ndhlovu, P D; Kjetland, E F; Baay, M F D; Mkhize-Kwitshana, Z L

    2017-12-06

    Cervical cancer is a major problem in women and it is important to find a suitable and acceptable screening method, especially among young in low-resource areas for future human papillomavirus (HPV) vaccine follow-up investigations. The study sought to test the acceptability of self-sampling as well as the suitability of the specimen collecting devices. Ninety-eight young women from rural KwaZulu-Natal were enrolled between March and July 2014. Collected genital specimens were transferred to colour indicator cards for HPV detection. Participants answered a questionnaire where they described their experiences with self-sampling. Samples were tested for high-risk HPV using GP5/6+ PCR. Of the enrolled participants, 91 answered questionnaires and indicated that self-sampling was preferred by 51/91 (56%) women while 40/91 (44%) indicated preference for sampling by a doctor (p = 0.023). The majority, 64% were comfortable using a swab, 22% preferred a brush while 11% were comfortable with both devices. Of the 98 self-sampled specimens 61 were negative for HPV in both specimens while 37 were HPV-positive in either brush or swab. Of the 37, 26 (70%) were HPV-positive in both brush and swab (kappa = 0.743) and 11 (30%) were discordant. Self-sampling was acceptable to the majority of participants in this rural area. The Dacron swab was the preferred device, and can be used in combination with colour indicator cards for comfortable self-sampling, easy storage and transport of specimens plus detection.

  20. The evaluation of Recombinant Immunoblot assay (RIBA and HCV-RNA test results in patients with low titer Anti-HCV positivity

    Directory of Open Access Journals (Sweden)

    Berrin Uzun

    2014-12-01

    Full Text Available Objectives: Laboratory diagnosis of hepatitis C virus (HCV infection is based on the detection of anti-HCV antibodies by enzyme immunoassay (EIA or chemiluminescence immunoassay (CIA techniques. However, a consensus related to the problem of low titer (Serum/Cut-off; S/C= 1.0 anti-HCV antibodies is still lacking. The study attempts to evaluate the clinical status of the patients with low titer anti-HCV antibodies detected by third generation anti-HCV tests during February 2013- May 2014 retrospectively. Methods: Serum samples were studied by Advia Centaur XP autoanalyser (Bayer-Siemens, Germany for anti-HCV, and line immunoassay (Inno-LIATM HCV Score, İnnogenetics, Belgium for anti-HCV confirmatory test, Cobas AmpliPre/Cobas AMPLICOR HCV Test (Roche diagnostics, Switzerland for HCV RNA. Results: A total of 55.631 serum samples were studied, and 55 of them were anti-HCV positive of which with low antibody levels (sample/cutoff [S/CO]. S/CO values ranged from 1.15 to 6.15. Seventeen (31% of patients who have low antibody levels were defined as positive and 2 (4% patients were intermittent and 36 (65% patients were negative with line immunoassay. HCV-RNA was not detected in any of the samples. Conclusions: It is thought that antibody positivity must be verified in cases of recurrent reactivity when considering the cost-effectiveness of molecular tests. In the study was concluded that the use of molecular tests would be appropriate diagnosis, and the effectiveness of treatment if necessary after evaluation of patients with biochemical analysis. J Clin Exp Invest 2014; 5 (4: 553-556

  1. ASPIRE: An automated sample positioning and irradiation system for radiation biology experiments at Inter University Accelerator Centre, New Delhi

    International Nuclear Information System (INIS)

    Kothari, Ashok; Barua, P.; Archunan, M.; Rani, Kusum; Subramanian, E.T.; Pujari, Geetanjali; Kaur, Harminder; Satyanarayanan, V.V.V.; Sarma, Asitikantha; Avasthi, D.K.

    2015-01-01

    An automated irradiation setup for biology samples has been built at Inter University Accelerator Centre (IUAC), New Delhi, India. It can automatically load and unload 20 biology samples in a run of experiment. It takes about 20 min [2% of the cell doubling time] to irradiate all the 20 samples. Cell doubling time is the time taken by the cells (kept in the medium) to grow double in numbers. The cells in the samples keep growing during entire of the experiment. The fluence irradiated to the samples is measured with two silicon surface barrier detectors. Tests show that the uniformity of fluence and dose of heavy ions reaches to 2% at the sample area in diameter of 40 mm. The accuracy of mean fluence at the center of the target area is within 1%. The irradiation setup can be used to the studies of radiation therapy, radiation dosimetry and molecular biology at the heavy ion accelerator. - Highlights: • Automated positioning and irradiation setup for biology samples at IUAC is built. • Loading and unloading of 20 biology samples can be automatically carried out. • Biologicals cells keep growing during entire experiment. • Fluence and dose of heavy ions are measured by two silicon barrier detectors. • Uniformity of fluence and dose of heavy ions at sample position reaches to 2%

  2. A One-Sample Test for Normality with Kernel Methods

    OpenAIRE

    Kellner , Jérémie; Celisse , Alain

    2015-01-01

    We propose a new one-sample test for normality in a Reproducing Kernel Hilbert Space (RKHS). Namely, we test the null-hypothesis of belonging to a given family of Gaussian distributions. Hence our procedure may be applied either to test data for normality or to test parameters (mean and covariance) if data are assumed Gaussian. Our test is based on the same principle as the MMD (Maximum Mean Discrepancy) which is usually used for two-sample tests such as homogeneity or independence testing. O...

  3. Advantages of analyzing postmortem brain samples in routine forensic drug screening—case series of three non-natural deaths tested positive for lysergic acid diethylamide (LSD)

    DEFF Research Database (Denmark)

    Mardal, Marie; Johansen, Sys Stybe; Thomsen, Ragnar

    2017-01-01

    Three case reports are presented, including autopsy findings and toxicological screening results, which were tested positive for the potent hallucinogenic drug lysergic acid diethylamide (LSD). LSD and its main metabolites were quantified in brain tissue and femoral blood, and furthermore hematoma...... and urine when available. LSD, its main metabolite 2-oxo-3-hydroxy-LSD (oxo-HO-LSD), and iso-LSD were quantified in biological samples according to a previously published procedure involving liquid-liquid extraction and ultra-high performance liquid chromatography − tandem mass spectrometry (UHPLC......-MS/MS). LSD was measured in the brain tissue of all presented cases at a concentration level from 0.34 −10.8 μg/kg. The concentration level in the target organ was higher than in peripheral blood. Additional psychoactive compounds were quantified in blood and brain tissue, though all below toxic concentration...

  4. 40 CFR 205.160-2 - Test sample selection and preparation.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test sample selection and preparation... sample selection and preparation. (a) Vehicles comprising the sample which are required to be tested... maintained in any manner unless such preparation, tests, modifications, adjustments or maintenance are part...

  5. 30 CFR 14.5 - Test samples.

    Science.gov (United States)

    2010-07-01

    ... MINING PRODUCTS REQUIREMENTS FOR THE APPROVAL OF FLAME-RESISTANT CONVEYOR BELTS General Provisions § 14.5 Test samples. Upon request by MSHA, the applicant must submit 3 precut, unrolled, flat conveyor belt...

  6. Forward selection two sample binomial test

    Science.gov (United States)

    Wong, Kam-Fai; Wong, Weng-Kee; Lin, Miao-Shan

    2016-01-01

    Fisher’s exact test (FET) is a conditional method that is frequently used to analyze data in a 2 × 2 table for small samples. This test is conservative and attempts have been made to modify the test to make it less conservative. For example, Crans and Shuster (2008) proposed adding more points in the rejection region to make the test more powerful. We provide another way to modify the test to make it less conservative by using two independent binomial distributions as the reference distribution for the test statistic. We compare our new test with several methods and show that our test has advantages over existing methods in terms of control of the type 1 and type 2 errors. We reanalyze results from an oncology trial using our proposed method and our software which is freely available to the reader. PMID:27335577

  7. Performance of an adult Brazilian sample on the Trail Making Test and Stroop Test

    Directory of Open Access Journals (Sweden)

    Kenia Repiso Campanholo

    Full Text Available ABSTRACT Objective: The Trail Making Test (TMT and Stroop Test (ST are attention tests widely used in clinical practice and research. The aim of this study was to provide normative data for the adult Brazilian population and to study the influence of gender, age and education on the TMT parts A and B, and ST cards A, B and C. Methods: We recruited 1447 healthy subjects aged ≥18 years with an educational level of 0-25 years who were native speakers of Portuguese (Brazilian. The subjects were evaluated by the Matrix Reasoning and Vocabulary subtests of the Wechsler Adult Intelligence Scale-III, along with the TMTA, TMTB and ST A, B and C. Results: Among the participants, mean intellectual efficiency was 103.20 (SD: 12.0, age 41.0 (SD: 16.4 years and education 11.9 (SD: 5.6 years. There were significant differences between genders on the TMTA (p=0.002, TMTB (p=0.017 and STC (p=0.024. Age showed a positive correlation with all attention tests, whereas education showed a negative correlation. Gender was not found to be significant on the multiple linear regression model, but age and education maintained their interference. Conclusion: Gender did not have the major impact on attentional tasks observed for age and education, both of which should be considered in the stratification of normative samples.

  8. Risk of breast cancer after false-positive test results in screening mammography

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My Catarina; Risør, Louise Madeleine; Thorsted, Brian Larsen

    2012-01-01

    Screening for disease in healthy people inevitably leads to some false-positive tests in disease-free individuals. Normally, women with false-positive screening tests for breast cancer are referred back to routine screening. However, the long-term outcome for women with false-positive tests...

  9. High HIV Prevalence, Suboptimal HIV Testing, and Low Knowledge of HIV-Positive Serostatus Among Injection Drug Users in St. Petersburg, Russia

    Science.gov (United States)

    Toussova, Olga V.; Verevochkin, Sergei V.; Barbour, Russell; Heimer, Robert; Kozlov, Andrei P.

    2011-01-01

    The purpose of this analysis was to estimate human immunodeficiency virus (HIV) prevalence and testing patterns among injection drug users (IDUs) in St. Petersburg, Russia. HIV prevalence among 387 IDUs in the sample was 50%. Correlates of HIV-positive serostatus included unemployment, recent unsafe injections, and history/current sexually transmitted infection. Seventy-six percent had been HIV tested, but only 22% of those who did not report HIV-positive serostatus had been tested in the past 12 months and received their test result. Correlates of this measure included recent doctor visit and having been in prison or jail among men. Among the 193 HIV-infected participants, 36% were aware of their HIV-positive serostatus. HIV prevalence is high and continuing to increase in this population. Adequate coverage of HIV testing has not been achieved, resulting in poor knowledge of positive serostatus. Efforts are needed to better understand motivating and deterring factors for HIV testing in this setting. PMID:18843531

  10. Delayed Measurement of Eosin-5'-Maleimide Binding May Affect the Test Results of Highly Hemolyzed Samples In Vivo and In Vitro-A Case Study.

    Science.gov (United States)

    Ciepiela, Olga; Adamowicz-Salach, Anna; Zdziechowicz, Izabela; Kotuła, Iwona

    2016-11-01

    Diagnosis of hereditary spherocytosis (HS) is based on clinical evaluation and eosin-5'-maleimide (EMA) test. A decrease in EMA fluorescence compared with healthy individuals is typical for HS and serves as a basis for HS diagnosis. Sensitivity and specificity of the test is high and false-positive results rarely occur. Studies have shown that anticoagulated blood sample when stored at 4°C for 7 days do not affect the test results. This case study is about an autoimmune hemolytic anemia patient who showed a primary positive result for EMA test (decrease in EMA fluorescence-47% compared with 100% for samples of healthy individual), when the test was performed in the sample stored for 48 hours after venipuncture and before staining. An irrelevant decrease (92.5% compared with 100% for samples of healthy individual) was found when freshly collected sample was analyzed. On the basis of the results obtained, it is recommended that EMA staining should be performed on the same day of blood collection for patients with significant hemolysis.

  11. Evaluation of Patients with an Apparent False Positive Stool DNA Test: The Role of Repeat Stool DNA Testing.

    Science.gov (United States)

    Cooper, Gregory S; Markowitz, Sanford D; Chen, Zhengyi; Tuck, Missy; Willis, Joseph E; Berger, Barry M; Brenner, Dean E; Li, Li

    2018-03-07

    There is uncertainty as to the appropriate follow-up of patients who test positive on multimarker stool DNA (sDNA) testing and have a colonoscopy without neoplasia. To determine the prevalence of missed colonic or occult upper gastrointestinal neoplasia in patients with an apparent false positive sDNA. We prospectively identified 30 patients who tested positive with a commercially available sDNA followed by colonoscopy without neoplastic lesions. Patients were invited to undergo repeat sDNA at 11-29 months after the initial test followed by repeat colonoscopy and upper endoscopy. We determined the presence of neoplastic lesions on repeat evaluation stratified by results of repeat sDNA. Twelve patients were restudied. Seven patients had a negative second sDNA test and a normal second colonoscopy and upper endoscopy. In contrast, 5 of 12 subjects had a persistently positive second sDNA test, and 3 had positive findings, including a 3-cm sessile transverse colon adenoma with high-grade dysplasia, a 2-cm right colon sessile serrated adenoma with dysplasia, and a nonadvanced colon adenoma (p = 0.045). These corresponded to a positive predictive value of 0.60 (95% CI 0.17-1.00) and a negative predictive value of 1.00 (95% CI 1.00-1.00) for the second sDNA test. In addition, the medical records of all 30 subjects with apparent false positive testing were reviewed and no documented cases of malignant tumors were recorded. Repeat positive sDNA testing may identify a subset of patients with missed or occult colorectal neoplasia after negative colonoscopy for an initially positive sDNA. High-quality colonoscopy with careful attention to the right colon in patients with positive sDNA is critically important and may avoid false negative colonoscopy.

  12. Failure-censored accelerated life test sampling plans for Weibull distribution under expected test time constraint

    International Nuclear Information System (INIS)

    Bai, D.S.; Chun, Y.R.; Kim, J.G.

    1995-01-01

    This paper considers the design of life-test sampling plans based on failure-censored accelerated life tests. The lifetime distribution of products is assumed to be Weibull with a scale parameter that is a log linear function of a (possibly transformed) stress. Two levels of stress higher than the use condition stress, high and low, are used. Sampling plans with equal expected test times at high and low test stresses which satisfy the producer's and consumer's risk requirements and minimize the asymptotic variance of the test statistic used to decide lot acceptability are obtained. The properties of the proposed life-test sampling plans are investigated

  13. Test of a sample container for shipment of small size plutonium samples with PAT-2

    International Nuclear Information System (INIS)

    Kuhn, E.; Aigner, H.; Deron, S.

    1981-11-01

    A light-weight container for the air transport of plutonium, to be designated PAT-2, has been developed in the USA and is presently undergoing licensing. The very limited effective space for bearing plutonium required the design of small size sample canisters to meet the needs of international safeguards for the shipment of plutonium samples. The applicability of a small canister for the sampling of small size powder and solution samples has been tested in an intralaboratory experiment. The results of the experiment, based on the concept of pre-weighed samples, show that the tested canister can successfully be used for the sampling of small size PuO 2 -powder samples of homogeneous source material, as well as for dried aliquands of plutonium nitrate solutions. (author)

  14. Randomized comparison of vaginal self-sampling by standard vs. dry swabs for Human papillomavirus testing

    International Nuclear Information System (INIS)

    Eperon, Isabelle; Vassilakos, Pierre; Navarria, Isabelle; Menoud, Pierre-Alain; Gauthier, Aude; Pache, Jean-Claude; Boulvain, Michel; Untiet, Sarah; Petignat, Patrick

    2013-01-01

    To evaluate if human papillomavirus (HPV) self-sampling (Self-HPV) using a dry vaginal swab is a valid alternative for HPV testing. Women attending colposcopy clinic were recruited to collect two consecutive Self-HPV samples: a Self-HPV using a dry swab (S-DRY) and a Self-HPV using a standard wet transport medium (S-WET). These samples were analyzed for HPV using real time PCR (Roche Cobas). Participants were randomized to determine the order of the tests. Questionnaires assessing preferences and acceptability for both tests were conducted. Subsequently, women were invited for colposcopic examination; a physician collected a cervical sample (physician-sampling) with a broom-type device and placed it into a liquid-based cytology medium. Specimens were then processed for the production of cytology slides and a Hybrid Capture HPV DNA test (Qiagen) was performed from the residual liquid. Biopsies were performed if indicated. Unweighted kappa statistics (κ) and McNemar tests were used to measure the agreement among the sampling methods. A total of 120 women were randomized. Overall HPV prevalence was 68.7% (95% Confidence Interval (CI) 59.3–77.2) by S-WET, 54.4% (95% CI 44.8–63.9) by S-DRY and 53.8% (95% CI 43.8–63.7) by HC. Among paired samples (S-WET and S-DRY), the overall agreement was good (85.7%; 95% CI 77.8–91.6) and the κ was substantial (0.70; 95% CI 0.57-0.70). The proportion of positive type-specific HPV agreement was also good (77.3%; 95% CI 68.2-84.9). No differences in sensitivity for cervical intraepithelial neoplasia grade one (CIN1) or worse between the two Self-HPV tests were observed. Women reported the two Self-HPV tests as highly acceptable. Self-HPV using dry swab transfer does not appear to compromise specimen integrity. Further study in a large screening population is needed. ClinicalTrials.gov: http://clinicaltrials.gov/show/NCT01316120

  15. Advantages of analyzing postmortem brain samples in routine forensic drug screening-Case series of three non-natural deaths tested positive for lysergic acid diethylamide (LSD).

    Science.gov (United States)

    Mardal, Marie; Johansen, Sys Stybe; Thomsen, Ragnar; Linnet, Kristian

    2017-09-01

    Three case reports are presented, including autopsy findings and toxicological screening results, which were tested positive for the potent hallucinogenic drug lysergic acid diethylamide (LSD). LSD and its main metabolites were quantified in brain tissue and femoral blood, and furthermore hematoma and urine when available. LSD, its main metabolite 2-oxo-3-hydroxy-LSD (oxo-HO-LSD), and iso-LSD were quantified in biological samples according to a previously published procedure involving liquid-liquid extraction and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). LSD was measured in the brain tissue of all presented cases at a concentration level from 0.34-10.8μg/kg. The concentration level in the target organ was higher than in peripheral blood. Additional psychoactive compounds were quantified in blood and brain tissue, though all below toxic concentration levels. The cause of death in case 1 was collision-induced brain injury, while it was drowning in case 2 and 3 and thus not drug intoxication. However, the toxicological findings could help explain the decedent's inability to cope with brain injury or drowning incidents. The presented findings could help establish reference concentrations in brain samples and assist in interpretation of results from forensic drug screening in brain tissue. This is to the author's knowledge the first report of LSD, iso-LSD, and oxo-HO-LSD measured in brain tissue samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    International Nuclear Information System (INIS)

    Burnett, J.L.; Davies, A.V.

    2014-01-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a 140 Ba MDA is achievable after 1.5 days counting compared to 5–7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra Lynx TM multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident

  17. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    Science.gov (United States)

    Burnett, J. L.; Davies, A. V.

    2014-05-01

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a 140Ba MDA is achievable after 1.5 days counting compared to 5-7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra LynxTM multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident.

  18. Cosmic veto gamma-spectrometry for Comprehensive Nuclear-Test-Ban Treaty samples

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, J.L., E-mail: jonathan.burnett@awe.co.uk; Davies, A.V.

    2014-05-21

    The Comprehensive Nuclear-Test-Ban Treaty (CTBT) is supported by a global network of monitoring stations that perform high-resolution gamma-spectrometry on air filter samples for the identification of 85 radionuclides. At the UK CTBT Radionuclide Laboratory (GBL15), a novel cosmic veto gamma-spectrometer has been developed to improve the sensitivity of station measurements, providing a mean background reduction of 80.8% with mean MDA improvements of 45.6%. The CTBT laboratory requirement for a {sup 140}Ba MDA is achievable after 1.5 days counting compared to 5–7 days using conventional systems. The system consists of plastic scintillation plates that detect coincident cosmic-ray interactions within an HPGe gamma-spectrometer using the Canberra Lynx{sup TM} multi-channel analyser. The detector is remotely configurable using a TCP/IP interface and requires no dedicated coincidence electronics. It would be especially useful in preventing false-positives at remote station locations (e.g. Halley, Antarctica) where sample transfer to certified laboratories is logistically difficult. The improved sensitivity has been demonstrated for a CTBT air filter sample collected after the Fukushima incident.

  19. The problem of false-positive human papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Frederiksen, Maria Eiholm

    2013-01-01

    Human Papillomavirus (HPV) testing has been extensively studied in randomized controlled trials of primary cervical screening. Based on encouraging results concerning its high detection rates and a high negative predictive value for high-grade cervical intraepithelial neoplasia (CIN), HPV testing...... will probably replace cytology in future primary cervical screening. However, HPV testing is associated with more frequent false-positive tests compared to cytology. False-positive tests are defined as positive screening tests which are not subsequently confirmed with high-grade CIN. Several authors have...

  20. Computational methods and modeling. 1. Sampling a Position Uniformly in a Trilinear Hexahedral Volume

    International Nuclear Information System (INIS)

    Urbatsch, Todd J.; Evans, Thomas M.; Hughes, H. Grady

    2001-01-01

    Monte Carlo particle transport plays an important role in some multi-physics simulations. These simulations, which may additionally involve deterministic calculations, typically use a hexahedral or tetrahedral mesh. Trilinear hexahedrons are attractive for physics calculations because faces between cells are uniquely defined, distance-to-boundary calculations are deterministic, and hexahedral meshes tend to require fewer cells than tetrahedral meshes. We discuss one aspect of Monte Carlo transport: sampling a position in a tri-linear hexahedron, which is made up of eight control points, or nodes, and six bilinear faces, where each face is defined by four non-coplanar nodes in three-dimensional Cartesian space. We derive, code, and verify the exact sampling method and propose an approximation to it. Our proposed approximate method uses about one-third the memory and can be twice as fast as the exact sampling method, but we find that its inaccuracy limits its use to well-behaved hexahedrons. Daunted by the expense of the exact method, we propose an alternate approximate sampling method. First, calculate beforehand an approximate volume for each corner of the hexahedron by taking one-eighth of the volume of an imaginary parallelepiped defined by the corner node and the three nodes to which it is directly connected. For the sampling, assume separability in the parameters, and sample each parameter, in turn, from a linear pdf defined by the sum of the four corner volumes at each limit (-1 and 1) of the parameter. This method ignores the quadratic portion of the pdf, but it requires less storage, has simpler sampling, and needs no extra, on-the-fly calculations. We simplify verification by designing tests that consist of one or more cells that entirely fill a unit cube. Uniformly sampling complicated cells that fill a unit cube will result in uniformly sampling the unit cube. Unit cubes are easily analyzed. The first problem has four wedges (or tents, or A frames) whose

  1. Design, test, and calibration of an electrostatic beam position monitor

    Directory of Open Access Journals (Sweden)

    Maurice Cohen-Solal

    2010-03-01

    Full Text Available The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerators, while emphasizing the determination of the absolute beam position. We present details of the readout electronics, and describe the calibration of the BPM using a test station. For calculation and simulation of the electrical signals we developed a Mathematica script. The error analysis presented, on the basis of six BPMs installed in the high energy section of IPHI, demonstrates the expected accuracy of the position measurement. These studies also identify the parameters that could improve the performance of the beam position control. The experience from these developments is currently being used for the BPM design and test stand dedicated to the Spiral2 accelerator at Ganil-Caen which will deliver heavy ion beams.

  2. Design, test, and calibration of an electrostatic beam position monitor

    Science.gov (United States)

    Cohen-Solal, Maurice

    2010-03-01

    The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM) are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton) facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerators, while emphasizing the determination of the absolute beam position. We present details of the readout electronics, and describe the calibration of the BPM using a test station. For calculation and simulation of the electrical signals we developed a Mathematica script. The error analysis presented, on the basis of six BPMs installed in the high energy section of IPHI, demonstrates the expected accuracy of the position measurement. These studies also identify the parameters that could improve the performance of the beam position control. The experience from these developments is currently being used for the BPM design and test stand dedicated to the Spiral2 accelerator at Ganil-Caen which will deliver heavy ion beams.

  3. Outgassing tests on iras solar panel samples

    Science.gov (United States)

    Premat, G.; Zwaal, A.; Pennings, N. H.

    1980-01-01

    Several outgassing tests were carried out on representative solar panel samples in order to determine the extent of contamination that could be expected from this source. The materials for the construction of the solar panels were selected as a result of contamination obtained in micro volatile condensable materials tests.

  4. Herbalife hepatotoxicity: Evaluation of cases with positive reexposure tests.

    Science.gov (United States)

    Teschke, Rolf; Frenzel, Christian; Schulze, Johannes; Schwarzenboeck, Alexander; Eickhoff, Axel

    2013-07-27

    To analyze the validity of applied test criteria and causality assessment methods in assumed Herbalife hepatotoxicity with positive reexposure tests. We searched the Medline database for suspected cases of Herbalife hepatotoxicity and retrieved 53 cases including eight cases with a positive unintentional reexposure and a high causality level for Herbalife. First, analysis of these eight cases focused on the data quality of the positive reexposure cases, requiring a baseline value of alanine aminotransferase (ALT) Herbalife in these eight cases were probable (n = 1), unlikely (n = 4), and excluded (n = 3). Confounding variables included low data quality, alternative diagnoses, poor exclusion of important other causes, and comedication by drugs and herbs in 6/8 cases. More specifically, problems were evident in some cases regarding temporal association, daily doses, exact start and end dates of product use, actual data of laboratory parameters such as ALT, and exact dechallenge characteristics. Shortcomings included scattered exclusion of hepatitis A-C, cytomegalovirus and Epstein Barr virus infection with only globally presented or lacking parameters. Hepatitis E virus infection was considered in one single patient and found positive, infections by herpes simplex virus and varicella zoster virus were excluded in none. Only one case fulfilled positive reexposure test criteria in initially assumed Herbalife hepatotoxicity, with lower CIOMS based causality gradings for the other cases than hitherto proposed.

  5. Evidence Based Medicine; Positive and Negative Likelihood Ratios of Diagnostic Tests

    Directory of Open Access Journals (Sweden)

    Alireza Baratloo

    2015-10-01

    Full Text Available In the previous two parts of educational manuscript series in Emergency, we explained some screening characteristics of diagnostic tests including accuracy, sensitivity, specificity, and positive and negative predictive values. In the 3rd  part we aimed to explain positive and negative likelihood ratio (LR as one of the most reliable performance measures of a diagnostic test. To better understand this characteristic of a test, it is first necessary to fully understand the concept of sensitivity and specificity. So we strongly advise you to review the 1st part of this series again. In short, the likelihood ratios are about the percentage of people with and without a disease but having the same test result. The prevalence of a disease can directly influence screening characteristics of a diagnostic test, especially its sensitivity and specificity. Trying to eliminate this effect, LR was developed. Pre-test probability of a disease multiplied by positive or negative LR can estimate post-test probability. Therefore, LR is the most important characteristic of a test to rule out or rule in a diagnosis. A positive likelihood ratio > 1 means higher probability of the disease to be present in a patient with a positive test. The further from 1, either higher or lower, the stronger the evidence to rule in or rule out the disease, respectively. It is obvious that tests with LR close to one are less practical. On the other hand, LR further from one will have more value for application in medicine. Usually tests with 0.1 < LR > 10 are considered suitable for implication in routine practice.

  6. Testing Homogeneity in a Semiparametric Two-Sample Problem

    Directory of Open Access Journals (Sweden)

    Yukun Liu

    2012-01-01

    Full Text Available We study a two-sample homogeneity testing problem, in which one sample comes from a population with density f(x and the other is from a mixture population with mixture density (1−λf(x+λg(x. This problem arises naturally from many statistical applications such as test for partial differential gene expression in microarray study or genetic studies for gene mutation. Under the semiparametric assumption g(x=f(xeα+βx, a penalized empirical likelihood ratio test could be constructed, but its implementation is hindered by the fact that there is neither feasible algorithm for computing the test statistic nor available research results on its theoretical properties. To circumvent these difficulties, we propose an EM test based on the penalized empirical likelihood. We prove that the EM test has a simple chi-square limiting distribution, and we also demonstrate its competitive testing performances by simulations. A real-data example is used to illustrate the proposed methodology.

  7. A Fault Sample Simulation Approach for Virtual Testability Demonstration Test

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yong; QIU Jing; LIU Guanjun; YANG Peng

    2012-01-01

    Virtual testability demonstration test has many advantages,such as low cost,high efficiency,low risk and few restrictions.It brings new requirements to the fault sample generation.A fault sample simulation approach for virtual testability demonstration test based on stochastic process theory is proposed.First,the similarities and differences of fault sample generation between physical testability demonstration test and virtual testability demonstration test are discussed.Second,it is pointed out that the fault occurrence process subject to perfect repair is renewal process.Third,the interarrival time distribution function of the next fault event is given.Steps and flowcharts of fault sample generation are introduced.The number of faults and their occurrence time are obtained by statistical simulation.Finally,experiments are carried out on a stable tracking platform.Because a variety of types of life distributions and maintenance modes are considered and some assumptions are removed,the sample size and structure of fault sample simulation results are more similar to the actual results and more reasonable.The proposed method can effectively guide the fault injection in virtual testability demonstration test.

  8. Data Quality Objectives For Selecting Waste Samples To Test The Fluid Bed Steam Reformer Test

    International Nuclear Information System (INIS)

    Banning, D.L.

    2010-01-01

    This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Fluid Bed Steam Reformer testing. The type, quantity and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluid bed steam reformer (FBSR). A determination of the adequacy of the FBSR process to treat Hanford tank waste is required. The initial step in determining the adequacy of the FBSR process is to select archived waste samples from the 222-S Laboratory that will be used to test the FBSR process. Analyses of the selected samples will be required to confirm the samples meet the testing criteria.

  9. Using ELISPOT to expose false positive skin test conversion in tuberculosis contacts.

    Directory of Open Access Journals (Sweden)

    Philip C Hill

    2007-01-01

    Full Text Available Repeat tuberculin skin tests may be false positive due to boosting of waned immunity to past mycobacterial exposure. We evaluated whether an ELISPOT test could identify tuberculosis (TB contacts with boosting of immunity to non-tuberculous mycobacterial exposure.We conducted tuberculin and ELISPOT tests in 1665 TB contacts: 799 were tuberculin test negative and were offered a repeat test after three months. Those with tuberculin test conversion had an ELISPOT, chest X-ray and sputum analysis if appropriate. We compared converters with non-converters, assessed the probability of each of four combinations of ELISPOT results over the two time points and estimated boosting with adjustment for ELISPOT sensitivity and specificity. 704 (72% contacts had a repeat tuberculin test; 176 (25% had test conversion, which increased with exposure to a case (p = 0.002, increasing age (p = 0.0006 and BCG scar (p = 0.06. 114 tuberculin test converters had ELISPOT results: 16(14% were recruitment positive/follow-up positive, 9 (8% positive/negative, 34 (30% negative/positive, and 55 (48% were negative/negative. There was a significant non-linear effect of age for ELISPOT results in skin test converters (p = 0.038. Estimates of boosting ranged from 32%-41% of skin test converters with increasing age. Three converters were diagnosed with TB, two had ELISPOT results: both were positive, including one at recruitment.We estimate that approximately one third of tuberculin skin test conversion in Gambian TB case contacts is due to boosting of immunity to non-tuberculous mycobacterial exposure. Further longitudinal studies are required to confirm whether ELISPOT can reliably identify case contacts with tuberculin test conversion that would benefit most from prophylactic treatment.

  10. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests.

    Science.gov (United States)

    Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G

    2002-02-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.

  11. Acceptance test report for core sample trucks 3 and 4

    International Nuclear Information System (INIS)

    Corbett, J.E.

    1996-01-01

    The purpose of this Acceptance Test Report is to provide documentation for the acceptance testing of the rotary mode core sample trucks 3 and 4, designated as HO-68K-4600 and HO-68K-4647, respectively. This report conforms to the guidelines established in WHC-IP-1026, ''Engineering Practice Guidelines,'' Appendix M, ''Acceptance Test Procedures and Reports.'' Rotary mode core sample trucks 3 and 4 were based upon the design of the second core sample truck (HO-68K-4345) which was constructed to implement rotary mode sampling of the waste tanks at Hanford. Successful completion of acceptance testing on June 30, 1995 verified that all design requirements were met. This report is divided into four sections, beginning with general information. Acceptance testing was performed on trucks 3 and 4 during the months of March through June, 1995. All testing was performed at the ''Rock Slinger'' test site in the 200 West area. The sequence of testing was determined by equipment availability, and the initial revision of the Acceptance Test Procedure (ATP) was used for both trucks. Testing was directed by ICF-KH, with the support of WHC Characterization Equipment Engineering and Characterization Project Operations. Testing was completed per the ATP without discrepancies or deviations, except as noted

  12. Optimum sample size allocation to minimize cost or maximize power for the two-sample trimmed mean test.

    Science.gov (United States)

    Guo, Jiin-Huarng; Luh, Wei-Ming

    2009-05-01

    When planning a study, sample size determination is one of the most important tasks facing the researcher. The size will depend on the purpose of the study, the cost limitations, and the nature of the data. By specifying the standard deviation ratio and/or the sample size ratio, the present study considers the problem of heterogeneous variances and non-normality for Yuen's two-group test and develops sample size formulas to minimize the total cost or maximize the power of the test. For a given power, the sample size allocation ratio can be manipulated so that the proposed formulas can minimize the total cost, the total sample size, or the sum of total sample size and total cost. On the other hand, for a given total cost, the optimum sample size allocation ratio can maximize the statistical power of the test. After the sample size is determined, the present simulation applies Yuen's test to the sample generated, and then the procedure is validated in terms of Type I errors and power. Simulation results show that the proposed formulas can control Type I errors and achieve the desired power under the various conditions specified. Finally, the implications for determining sample sizes in experimental studies and future research are discussed.

  13. [Characteristics of allergic conjunctivitis with positive skin prick test].

    Science.gov (United States)

    Yang, S; Jiang, Y; Jin, Y M; Zhang, J Y; Li, Y

    2017-09-11

    Objective: To observe the clinical characteristics of allergic conjunctivitis, and the correlations with skin prick test results. Methods: A retrospective study. Forty patients with positive skin prick test result were included. Patients underwent an ophthalmologic examination to identify their primary presenting signs and symptoms. The allergy types were divided into 5 groups. All dates were analyzed for the dependence, normality and homogeneity of variance. Chi-square test, Mann-Whitney U test, Kruskal-Wallis H test and Spearman correlation analysis were performed accordingly. Results: Among 40 patients, 18(45.0%) had a clinical diagnosis of seasonal allergic conjunctivitis, 14(35.0%) had perennial allergic conjunctivitis, 5(12.5%) had vernal keratoconjunctivitis, and 2(5.0%) had atopic keratoconjunctivits, and 1(2.5%) had giant papillary conjunctivitis. There was no significant difference in the number of symptoms and signs score among different types of allergic conjunctivitis, the score of itching and hyperemia had a positive relationship with the number of positive allergens ( r =0.74, Ptest of the allergen, the more symptoms and signs encountered in terms of severity. Conclusion: Seasonal allergic conjunctivitis was the most prevalent disorder, the most important clinical characteristics of allergic conjunctivitis are itching and conjunctival congestion, the main allergens are dust and pollens, patients may be sensitive to multiple allergens. (Chin J Ophthalmol, 2017, 53: 689-693) .

  14. Usefulness of exercise ECG test with nitroglycerin and exercise cardiac scintigraphy in patients with false positive exercise ECG test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro

    1984-01-01

    The purpose of this study is to evaluate the clinical usefulness of exercise (Ex) ECG test with sublingual nitroglycerin (NTG) and Ex cardiac scintigraphy in differentiating false positive responses from true positive responses of Ex ECG test. We examined 7 pts (age : 46+-7 years) with true positive Ex ECG test (TP) and 8 pts (age : 55+-10 years) with false positive Ex ECG test (FP). TP had significant coronary artery disease and FP did not. Ex test was done by multistage ergometer test. In 5 pts of TP and all pts of FP, Ex cardiac scintigraphy was performed. In TP, Ex cardiac scintigraphy revealed reversible perfusion deficit, but not in FP. NTG was administered 3 minutes before Ex test was started. Ex test with NTG was terminated at the same load as Ex test without NTG. Pressure-rate products at the end point of Ex test did not show significant difference between Ex test without NTG and that with NTG (TP: 203x10 2 , 213x10 2 , FP: 196x10 2 , 206x10 2 , respectively). In 7 pts of FP, ST depression in Ex test without NTG was not improved in Ex test with NTG. On the other hand, in all pts of TP, ST depression seen in Ex test without NTG, was not observed in Ex test with NTG. It may be concluded that Ex cardiac scintigraphy is diagnostic for differentiation of false positive responses from true positive responses of Ex ECG test, as well as Ex ECG test with NTG is. (author)

  15. Tests on CANDU fuel elements sheath samples

    International Nuclear Information System (INIS)

    Ionescu, S.; Uta, O.; Mincu, M.; Prisecaru, I.

    2016-01-01

    This work is a study of the behavior of CANDU fuel elements after irradiation. The tests are made on ring samples taken from fuel cladding in INR Pitesti. This paper presents the results of examinations performed in the Post Irradiation Examination Laboratory. By metallographic and ceramographic examination we determinate that the hydride precipitates are orientated parallel to the cladding surface. A content of hydrogen of about 120 ppm was estimated. After the preliminary tests, ring samples were cut from the fuel rod, and were subject of tensile test on an INSTRON 5569 model machine in order to evaluate the changes of their mechanical properties as consequence of irradiation. Scanning electron microscopy was performed on a microscope model TESCAN MIRA II LMU CS with Schottky FE emitter and variable pressure. The analysis shows that the central zone has deeper dimples, whereas on the outer zone, the dimples are tilted and smaller. (authors)

  16. 17 CFR Appendix B to Part 420 - Sample Large Position Report

    Science.gov (United States)

    2010-04-01

    ..., and as collateral for financial derivatives and other securities transactions $ Total Memorandum 1... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Sample Large Position Report B Appendix B to Part 420 Commodity and Securities Exchanges DEPARTMENT OF THE TREASURY REGULATIONS UNDER...

  17. Vertical jumping tests in volleyball: reliability, validity, and playing-position specifics.

    Science.gov (United States)

    Sattler, Tine; Sekulic, Damir; Hadzic, Vedran; Uljevic, Ognjen; Dervisevic, Edvin

    2012-06-01

    Vertical jumping is known to be important in volleyball, and jumping performance tests are frequently studied for their reliability and validity. However, most studies concerning jumping in volleyball have dealt with standard rather than sport-specific jumping procedures and tests. The aims of this study, therefore, were (a) to determine the reliability and factorial validity of 2 volleyball-specific jumping tests, the block jump (BJ) test and the attack jump (AJ) test, relative to 2 frequently used and systematically validated jumping tests, the countermovement jump test and the squat jump test and (b) to establish volleyball position-specific differences in the jumping tests and simple anthropometric indices (body height [BH], body weight, and body mass index [BMI]). The BJ was performed from a defensive volleyball position, with the hands positioned in front of the chest. During an AJ, the players used a 2- to 3-step approach and performed a drop jump with an arm swing followed by a quick vertical jump. A total of 95 high-level volleyball players (all men) participated in this study. The reliability of the jumping tests ranged from 0.97 to 0.99 for Cronbach's alpha coefficients, from 0.93 to 0.97 for interitem correlation coefficients and from 2.1 to 2.8 for coefficients of variation. The highest reliability was found for the specific jumping tests. The factor analysis extracted one significant component, and all of the tests were highly intercorrelated. The analysis of variance with post hoc analysis showed significant differences between 5 playing positions in some of the jumping tests. In general, receivers had a greater jumping capacity, followed by libero players. The differences in jumping capacities should be emphasized vis-a-vis differences in the anthropometric measures of players, where middle hitters had higher BH and body weight, followed by opposite hitters and receivers, with no differences in the BMI between positions.

  18. On Wasserstein Two-Sample Testing and Related Families of Nonparametric Tests

    Directory of Open Access Journals (Sweden)

    Aaditya Ramdas

    2017-01-01

    Full Text Available Nonparametric two-sample or homogeneity testing is a decision theoretic problem that involves identifying differences between two random variables without making parametric assumptions about their underlying distributions. The literature is old and rich, with a wide variety of statistics having being designed and analyzed, both for the unidimensional and the multivariate setting. Inthisshortsurvey,wefocusonteststatisticsthatinvolvetheWassersteindistance. Usingan entropic smoothing of the Wasserstein distance, we connect these to very different tests including multivariate methods involving energy statistics and kernel based maximum mean discrepancy and univariate methods like the Kolmogorov–Smirnov test, probability or quantile (PP/QQ plots and receiver operating characteristic or ordinal dominance (ROC/ODC curves. Some observations are implicit in the literature, while others seem to have not been noticed thus far. Given nonparametric two-sample testing’s classical and continued importance, we aim to provide useful connections for theorists and practitioners familiar with one subset of methods but not others.

  19. Analysis of HIV subtypes and the phylogenetic tree in HIV-positive samples from Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Zahrani, Alhusain J.

    2008-01-01

    Objective was to assess the prevalence of HIV-1 genetic subtypes in Saudi Arabia in samples that are serologically positive for HIV-1 and compare the HIV-1 genetic subtypes prevalent in Saudi Arabia with the subtypes prevalent in other countries. Thirty-nine HIV-1 positive samples were analyzed for HIV-1 subtypes using molecular techniques. The study is retrospective study that was conducted in Dammam, Kingdom of Saudi Arabia and in Abbott laboratories (United States of America) from2004 to 2007. All samples were seropositive for HIV-1 group M. Of the 39 seropositive samples, only 12 were polymerase chain reaction positive. Subtype C is the most common virus strain as it occurred in 58% of these samples; subtype B occurred in 17%; subtypes A, D and G were found in 8% each. The phylogenetic tree was also identified for the isolates. Detection of HIV subtypes is important for epidemiological purposes and may help in tracing the source of HIV infections in the Kingdom of Saudi Arabia. (author)

  20. Reactivation of tuberculosis during immunosuppressive treatment in a patient with a positive QuantiFERON-RD1 test

    DEFF Research Database (Denmark)

    Ravn, Pernille; Munk, Martin E; Andersen, Ase Bengaard

    2004-01-01

    A patient with polymyositis developed tuberculosis during immunosuppressive treatment. Tuberculin Skin Test and chest X-ray failed to demonstrate latent tuberculosis, whereas a blood sample that was tested with a modified QuantiFERON-TB-assay, using the recombinant ESAT-6 and CFP-10, was positive...... indicating that this patient was latently infected before immunosuppressive therapy. This case indicates the risk of progressing from latent to active tuberculosis given that the subject is RD1 responsive, and we believe that preventive anti-tuberculous treatment could have prevented this case...... of tuberculosis. We suggest that RD1 based tests are evaluated further in immunocompromised patients....

  1. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false

  2. Occupational position and its relation to mental distress in a random sample of Danish residents

    DEFF Research Database (Denmark)

    Rugulies, Reiner Ernst; Madsen, Ida E H; Nielsen, Maj Britt D

    2010-01-01

    PURPOSE: To analyze the distribution of depressive, anxiety, and somatization symptoms across different occupational positions in a random sample of Danish residents. METHODS: The study sample consisted of 591 Danish residents (50% women), aged 20-65, drawn from an age- and gender-stratified random...... sample of the Danish population. Participants filled out a survey that included the 92 item version of the Hopkins Symptom Checklist (SCL-92). We categorized occupational position into seven groups: high- and low-grade non-manual workers, skilled and unskilled manual workers, high- and low-grade self...

  3. Biological samples positioning device for irradiations on a radial channel at the nuclear research reactor

    International Nuclear Information System (INIS)

    Rodriguez Gual, Maritza; Mas Milian, Felix; Deppman, Airton; Pinto Coelho, Paulo Rogerio

    2010-01-01

    For the demand of an experimental device for biological samples positioning system for irradiations on a radial channel at the nuclear research reactor in operation was constructed and started up a device for the place and remove of the biological samples from the irradiation channels without interrupting the operation of the reactor. The economical valuations are effected comparing with another type of device with the same functions. This work formed part of an international project between Cuba and Brazil that undertook the study of the induced damages by various types of ionizing radiation in DNA molecules. Was experimentally tested the proposed solution, which demonstrates the practical validity of the device. As a result of the work, the experimental device for biological samples irradiations are installed and operating in the radial beam hole No3(BH3) for more than five years at the IEA-R1 Brazilian research reactor according to the solicited requirements the device. The designed device increases considerably the type of studies can be conducted in this reactor. Its practical application in research taking place in that facility, in the field of radiobiology and dosimetry, and so on is immediate

  4. Reliability and validity of the Positive Mental Health Questionnaire in a sample of Spanish university students.

    Science.gov (United States)

    Roldán-Merino, J; Lluch-Canut, M T; Casas, I; Sanromà-Ortíz, M; Ferré-Grau, C; Sequeira, C; Falcó-Pegueroles, A; Soares, D; Puig-Llobet, M

    2017-03-01

    WHAT IS KNOWN ON THE SUBJECT?: In general, the current studies of positive mental health use questionnaires or parts thereof. However, while these questionnaires evaluate aspects of positive mental health, they fail to measure the construct itself. WHAT DOES THIS PAPER ADD TO EXISTING KNOWLEDGE?: The widespread use and the lack of specific questionnaires for evaluating the positive mental health construct justify the need to measure the robustness of the Positive Mental Health Questionnaire. Also six factors are proposed to measure positive mental health. WHAT ARE THE IMPLICATIONS FOR PRACTICE?: The availability of a good questionnaire to measure positive mental health in university students is useful not only to promote mental health but also to strengthen the curricula of future professionals. Introduction Nursing has a relevant role in managing mental health. It is important to identify and thereafter to enhance positive aspects of mental health among university nursing students. Aim The aim of the present study was to analyse the psychometric properties of the Positive Mental Health Questionnaire (PMHQ) in terms of reliability and validity using confirmatory factor analysis in a sample of university students. Method A cross-sectional study was carried out in a sample of 1091 students at 4 nursing schools in Catalonia, Spain. The reliability of the PMHQ was measured by means of Cronbach's alpha coefficient, and the test-retest stability was measured with the intraclass correlation coefficient (ICC). Confirmatory factor analysis was used to determine the validity of the factorial structure. Results Cronbach's alpha coefficient was satisfactory (>0.70) for four of the six subscales or dimensions and ranged from 0.54 to 0.79. ICC analysis was satisfactory for the six subscales or dimensions. The hypothesis was confirmed in the analysis of the correlations between subclasses and the overall scale, with the strongest correlations being found between the majority of

  5. Group SkSP-R sampling plan for accelerated life tests

    Indian Academy of Sciences (India)

    Muhammad Aslam

    2017-09-15

    Sep 15, 2017 ... SkSP-R sampling; life test; Weibull distribution; producer's risk; ... designed a sampling plan under a time-truncated life test .... adjusted using an acceleration factor. ... where P is the probability of lot acceptance for a single.

  6. HIV-positive MSM's knowledge of HPV and anal cancer self-sampling: A scoping review.

    Science.gov (United States)

    Poon, M K L; Wong, J P H; Li, A T W; Manuba, M; Bisignano, A; Owino, M; Vahabi, M

    2018-02-01

    Human papillomavirus (hpv) infection is the cause of anal squamous cell cancer (ascc) in 80% of cases. Available research has also shown high prevalence of anal hpv infection among men who have sex with men (msm). However, hpv vaccination is low among msm in Canada. In light of this information, we conducted a scoping review with the aim of exploring (1) the knowledge of hpv and anal cancer among hiv-positive msm and (2) the acceptability of hpv and anal cancer self-sampling in this population. In conducting the review, we searched five electronic databases for peer-reviewed articles and abstracts published in English, between 2007 and 2017. A total of 803 articles were retrieved; after accounting for duplicates ( n= 40) and unmet criteria ( n= 754), a total of 794 articles were excluded. A final total of nine articles were used in this review. Results of this review show that hiv-positive msm have limited knowledge regarding the risks of anal cancer associated with hiv and hpv coinfection. Furthermore, there is limited research on hpv and anal cancer self-sampling in this population. However, the review of available studies suggested that hiv-positive msm were open to anal cancer self-sampling. It also identified potential barriers to self-sampling. In conclusion, we provide suggestions and future directions for policy-makers and educators to develop inclusive and accessible strategies to reach hiv-positive msm regarding anal cancer education and self-screening.

  7. Adaptive designs for the one-sample log-rank test.

    Science.gov (United States)

    Schmidt, Rene; Faldum, Andreas; Kwiecien, Robert

    2017-09-22

    Traditional designs in phase IIa cancer trials are single-arm designs with a binary outcome, for example, tumor response. In some settings, however, a time-to-event endpoint might appear more appropriate, particularly in the presence of loss to follow-up. Then the one-sample log-rank test might be the method of choice. It allows to compare the survival curve of the patients under treatment to a prespecified reference survival curve. The reference curve usually represents the expected survival under standard of the care. In this work, convergence of the one-sample log-rank statistic to Brownian motion is proven using Rebolledo's martingale central limit theorem while accounting for staggered entry times of the patients. On this basis, a confirmatory adaptive one-sample log-rank test is proposed where provision is made for data dependent sample size reassessment. The focus is to apply the inverse normal method. This is done in two different directions. The first strategy exploits the independent increments property of the one-sample log-rank statistic. The second strategy is based on the patient-wise separation principle. It is shown by simulation that the proposed adaptive test might help to rescue an underpowered trial and at the same time lowers the average sample number (ASN) under the null hypothesis as compared to a single-stage fixed sample design. © 2017, The International Biometric Society.

  8. A two-sample Bayesian t-test for microarray data

    Directory of Open Access Journals (Sweden)

    Dimmic Matthew W

    2006-03-01

    Full Text Available Abstract Background Determining whether a gene is differentially expressed in two different samples remains an important statistical problem. Prior work in this area has featured the use of t-tests with pooled estimates of the sample variance based on similarly expressed genes. These methods do not display consistent behavior across the entire range of pooling and can be biased when the prior hyperparameters are specified heuristically. Results A two-sample Bayesian t-test is proposed for use in determining whether a gene is differentially expressed in two different samples. The test method is an extension of earlier work that made use of point estimates for the variance. The method proposed here explicitly calculates in analytic form the marginal distribution for the difference in the mean expression of two samples, obviating the need for point estimates of the variance without recourse to posterior simulation. The prior distribution involves a single hyperparameter that can be calculated in a statistically rigorous manner, making clear the connection between the prior degrees of freedom and prior variance. Conclusion The test is easy to understand and implement and application to both real and simulated data shows that the method has equal or greater power compared to the previous method and demonstrates consistent Type I error rates. The test is generally applicable outside the microarray field to any situation where prior information about the variance is available and is not limited to cases where estimates of the variance are based on many similar observations.

  9. Comparison of Antigen Detection and Nested PCR in CSF Samples of HIV Positive and Negative Patients with Suspected Cryptococcal Meningitis in a Tertiary Care Hospital.

    Science.gov (United States)

    Kumari, Sunita; Verma, Rajesh Kumar; Singh, Dharmendra Prasad; Yadav, Ramakant

    2016-04-01

    The cases of cryptococcal meningitis and other forms of cryptococcosis have increased in recent time and the present scenario of the condition with significant morbidity and mortality is actually posing a serious threat to the community, so an early and prompt diagnosis is necessary to prevent serious complications and thus improving the overall disease outcome. Comparison of diagnostic efficacy of nested Polymerase Chain Reaction (PCR) with Latex Agglutination Test (LAT) in the Cerebro Spinal Fluid (CSF) samples of the cases of meningitis in HIV positive and negative cases. We have compared the diagnostic efficacy of Latex Agglutination Test (LAT) with nested Polymerase Chain Reaction (PCR) in 200 Cerebrospinal Fluid (CSF) samples, including 14 HIV positive also, in the cases of suspected cryptococcal meningitis. Nested PCR was done in all cases reporting positive by LAT and results were then compared with that of India ink and culture on Sabouraud Dextrose Agar (SDA), and the isolates were further identified by urease, nitrate and sugar assimilation tests. Of the 200 cases, including 14 HIV positive, LAT was positive in 46 cases while 154 were negative. Out of these 46 LAT positive cases, nested PCR was positive in 40 cases only, while culture and India ink was positive in 38 and 33 cases respectively. Majority of the cases, 30 (65.2%) were between age group 21-50 years, while 2 (4.3%) in 0-20, and 14 (30.4%) in 51-80 years age group. Although negative staining like India ink and nigrosin are most widely used techniques, but these suffer with subjective error. Rapid method like LAT is available but it always has the scope of false positive and negative results. In such cases nested PCR can help in establishing final diagnosis.

  10. Sampling theorem for geometric moment determination and its application to a laser beam position detector.

    Science.gov (United States)

    Loce, R P; Jodoin, R E

    1990-09-10

    Using the tools of Fourier analysis, a sampling requirement is derived that assures that sufficient information is contained within the samples of a distribution to calculate accurately geometric moments of that distribution. The derivation follows the standard textbook derivation of the Whittaker-Shannon sampling theorem, which is used for reconstruction, but further insight leads to a coarser minimum sampling interval for moment determination. The need for fewer samples to determine moments agrees with intuition since less information should be required to determine a characteristic of a distribution compared with that required to construct the distribution. A formula for calculation of the moments from these samples is also derived. A numerical analysis is performed to quantify the accuracy of the calculated first moment for practical nonideal sampling conditions. The theory is applied to a high speed laser beam position detector, which uses the normalized first moment to measure raster line positional accuracy in a laser printer. The effects of the laser irradiance profile, sampling aperture, number of samples acquired, quantization, and noise are taken into account.

  11. Quality standards for sample collection in coagulation testing.

    Science.gov (United States)

    Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Lima-Oliveira, Gabriel; Guidi, Gian Cesare; Favaloro, Emmanuel J

    2012-09-01

    Preanalytical activities, especially those directly connected with blood sample collection and handling, are the most vulnerable steps throughout the testing process. The receipt of unsuitable samples is commonplace in laboratory practice and represents a serious problem, given the reliability of test results can be adversely compromised following analysis of these specimens. The basic criteria for an appropriate and safe venipuncture are nearly identical to those used for collecting blood for clinical chemistry and immunochemistry testing, and entail proper patient identification, use of the correct technique, as well as appropriate devices and needles. There are, however, some peculiar aspects, which are deemed to be particularly critical when collecting quality specimens for clot-based tests, and these require clearer recognition. These include prevention of prolonged venous stasis, collection of nonhemolyzed specimens, order of draw, and appropriate filling and mixing of the primary collection tubes. All of these important preanalytical issues are discussed in this article, and evidence-based suggestions as well as recommendations on how to obtain a high-quality sample for coagulation testing are also illustrated. We have also performed an investigation aimed to identify variation of test results due to underfilling of primary blood tubes, and have identified a clinically significant bias in test results when tubes are drawn at less than 89% of total fill for activated partial thromboplastin time, less than 78% for fibrinogen, and less than 67% for coagulation factor VIII, whereas prothrombin time and activated protein C resistance remain relatively reliable even in tubes drawn at 67% of the nominal volume. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Histamine release positive test associates with disease remission in chronic spontaneous urticaria

    DEFF Research Database (Denmark)

    Berti, A; Yacoub, M R; Skov, Per Stahl

    2017-01-01

    the correlations between HR test results and demographic features, quality of life, disease activity, clinical course, and autologous serum and plasma skin tests (ASST and APST). Results. All patients with positive HR test (9/9, 100%) had a more severe disease activity at onset (urticaria activity score, UAS > 2......Summary: Background. Histamine release (HR) test has previously been shown to predict the presence of endogenous histamine-releasing factors in chronic spontaneous urticaria (CSU). Objectives and methods. Twenty CSU patients unresponsive to antihistamine treatment were enrolled in order to evaluate...... with a positive HR test had a significant reduction of disease activity (p = 0.003) whereas patients with a negative HR test did not (p > 0.05), leading to disease remission and antihistamine treatment withdrawal in 67% (6/9) of positive HR test patients versus 18% (2/11) of negative HR test patients (p = 0...

  13. Reactivation of tuberculosis during immunosuppressive treatment in a patient with a positive QuantiFERON-RD1 test

    DEFF Research Database (Denmark)

    Ravn, Pernille; Munk, Martin E; Andersen, Ase Bengaard

    2004-01-01

    A patient with polymyositis developed tuberculosis during immunosuppressive treatment. Tuberculin Skin Test and chest X-ray failed to demonstrate latent tuberculosis, whereas a blood sample that was tested with a modified QuantiFERON-TB-assay, using the recombinant ESAT-6 and CFP-10, was positive...... indicating that this patient was latently infected before immunosuppressive therapy. This case indicates the risk of progressing from latent to active tuberculosis given that the subject is RD1 responsive, and we believe that preventive anti-tuberculous treatment could have prevented this case...

  14. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    Energy Technology Data Exchange (ETDEWEB)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-11-19

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of ..beta..-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment.

  15. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    International Nuclear Information System (INIS)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-01-01

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of #betta#-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment

  16. 10 CFR 707.7 - Random drug testing requirements and identification of testing designated positions.

    Science.gov (United States)

    2010-01-01

    ... contractor, to have the potential to significantly affect the environment, public health and safety, or... evidence of the use of illegal drugs of employees in testing designated positions identified in this... section shall provide for random tests at a rate equal to 30 percent of the total number of employees in...

  17. CHARACTERIZATION AND ACTUAL WASTE TEST WITH TANK 5F SAMPLES

    International Nuclear Information System (INIS)

    Fletcher, D.

    2007-01-01

    The initial phase of bulk waste removal operations was recently completed in Tank 5F. Video inspection of the tank indicates several mounds of sludge still remain in the tank. Additionally, a mound of white solids was observed under Riser 5. In support of chemical cleaning and heel removal programs, samples of the sludge and the mound of white solids were obtained from the tank for characterization and testing. A core sample of the sludge and Super Snapper sample of the white solids were characterized. A supernate dip sample from Tank 7F was also characterized. A portion of the sludge was used in two tank cleaning tests using oxalic acid at 50 C and 75 C. The filtered oxalic acid from the tank cleaning tests was subsequently neutralized by addition to a simulated Tank 7F supernate. Solids and liquid samples from the tank cleaning test and neutralization test were characterized. A separate report documents the results of the gas generation from the tank cleaning test using oxalic acid and Tank 5F sludge. The characterization results for the Tank 5F sludge sample (FTF-05-06-55) appear quite good with respect to the tight precision of the sample replicates, good results for the glass standards, and minimal contamination found in the blanks and glass standards. The aqua regia and sodium peroxide fusion data also show good agreement between the two dissolution methods. Iron dominates the sludge composition with other major contributors being uranium, manganese, nickel, sodium, aluminum, and silicon. The low sodium value for the sludge reflects the absence of supernate present in the sample due to the core sampler employed for obtaining the sample. The XRD and CSEM results for the Super Snapper salt sample (i.e., white solids) from Tank 5F (FTF-05-07-1) indicate the material contains hydrated sodium carbonate and bicarbonate salts along with some aluminum hydroxide. These compounds likely precipitated from the supernate in the tank. A solubility test showed the material

  18. Self- versus physician-collected samples for the follow-up of human papillomavirus-positive women in sub-Saharan Africa

    Directory of Open Access Journals (Sweden)

    Viviano M

    2018-04-01

    Full Text Available Manuela Viviano,1,* Phuong Lien Tran,1,* Bruno Kenfack,2 Rosa Catarino,1 Mohamed Akaaboune,1,† Liliane Temogne,2 Eveline Tincho Foguem,2 Pierre Vassilakos,3 Patrick Petignat1 1Gynecology Division, Geneva University Hospitals, Geneva, Switzerland; 2Department of Biomedical Sciences, University of Dschang, Dschang, Cameroon; 3Geneva Foundation for Medical Education and Research, Geneva, Switzerland *These authors contributed equally to the work †MA passed away on July 31, 2017 Introduction: Human papillomavirus (HPV testing is a suitable tool for primary cervical cancer (CC screening and follow-up in low-resource settings. Vaginal samples taken by women themselves (Self-HPV are an interesting alternative to physician-performed sampling (Dr-HPV. Our aim was to assess the performance of Self-HPV and Dr-HPV at 6 and 12 months following a CC screening campaign. Methods: This study was carried out at the Dschang District Hospital, Cameroon. Women aged 30–49 years were recruited in a CC screening campaign. HPV-positive women, of whom 2/3 were treated with thermoablation because of abnormal results at baseline screening, were invited to participate in a follow-up study. Self- and Dr-HPV, as well as cytology, were performed at 6 and 12 months. HPV samples were analyzed using the Xpert HPV assay. Sensitivity and specificity for the detection of low-grade squamous intraepithelial lesion or worse and of high-grade squamous intraepithelial lesion or worse were calculated for Self-HPV and Dr-HPV, using cytology as the reference diagnosis. Results: Overall, 188 HPV-positive women were invited to attend follow-up. The obtained follow-up visits’ attendance was 154 (81.9% and 131 (69.7% at 6 and 12 months, respectively. While the overall performance of Dr-HPV at 6 months was slightly superior, Self-HPV showed an improved sensitivity for HSIL+ detection at 12 months when compared with Dr-HPV (83.3% [95% CI 41.8–98.9] versus 71.4% [95% CI 21.5–95

  19. Cross-validation of the Dot Counting Test in a large sample of credible and non-credible patients referred for neuropsychological testing.

    Science.gov (United States)

    McCaul, Courtney; Boone, Kyle B; Ermshar, Annette; Cottingham, Maria; Victor, Tara L; Ziegler, Elizabeth; Zeller, Michelle A; Wright, Matthew

    2018-01-18

    To cross-validate the Dot Counting Test in a large neuropsychological sample. Dot Counting Test scores were compared in credible (n = 142) and non-credible (n = 335) neuropsychology referrals. Non-credible patients scored significantly higher than credible patients on all Dot Counting Test scores. While the original E-score cut-off of ≥17 achieved excellent specificity (96.5%), it was associated with mediocre sensitivity (52.8%). However, the cut-off could be substantially lowered to ≥13.80, while still maintaining adequate specificity (≥90%), and raising sensitivity to 70.0%. Examination of non-credible subgroups revealed that Dot Counting Test sensitivity in feigned mild traumatic brain injury (mTBI) was 55.8%, whereas sensitivity was 90.6% in patients with non-credible cognitive dysfunction in the context of claimed psychosis, and 81.0% in patients with non-credible cognitive performance in depression or severe TBI. Thus, the Dot Counting Test may have a particular role in detection of non-credible cognitive symptoms in claimed psychiatric disorders. Alternative to use of the E-score, failure on ≥1 cut-offs applied to individual Dot Counting Test scores (≥6.0″ for mean grouped dot counting time, ≥10.0″ for mean ungrouped dot counting time, and ≥4 errors), occurred in 11.3% of the credible sample, while nearly two-thirds (63.6%) of the non-credible sample failed one of more of these cut-offs. An E-score cut-off of 13.80, or failure on ≥1 individual score cut-offs, resulted in few false positive identifications in credible patients, and achieved high sensitivity (64.0-70.0%), and therefore appear appropriate for use in identifying neurocognitive performance invalidity.

  20. Test plan for evaluating the performance of the in-tank fluidic sampling system

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    The PHMC will provide Low Activity Wastes (LAW) tank wastes for final treatment by a privatization contractor from double-shell feed tanks, 241-AP-102 and 241-AP-104, Concerns about the inability of the baseline ''grab'' sampling to provide large volume samples within time constraints has led to the development of a conceptual sampling system that would be deployed in a feed tank riser, This sampling system will provide large volume, representative samples without the environmental, radiation exposure, and sample volume impacts of the current base-line ''grab'' sampling method. This test plan identifies ''proof-of-principle'' cold tests for the conceptual sampling system using simulant materials. The need for additional testing was identified as a result of completing tests described in the revision test plan document, Revision 1 outlines tests that will evaluate the performance and ability to provide samples that are representative of a tanks' content within a 95 percent confidence interval, to recovery from plugging, to sample supernatant wastes with over 25 wt% solids content, and to evaluate the impact of sampling at different heights within the feed tank. The test plan also identifies operating parameters that will optimize the performance of the sampling system

  1. Genetic Testing and Post-Testing Decision Making among BRCA-Positive Mutation Women: A Psychosocial Approach.

    Science.gov (United States)

    Hesse-Biber, Sharlene; An, Chen

    2016-10-01

    Through an analysis of an online survey of women who tested positive for the BRCA genetic mutation for breast cancer, this research uses a social constructionist and feminist standpoint lens to understand the decision-making process that leads BRCA-positive women to choose genetic testing. Additionally, this research examines how they socially construct and understand their risk for developing breast cancer, as well as which treatment options they undergo post-testing. BRCA-positive women re-frame their statistical medical risk for developing cancer and their post-testing treatment choices through a broad psychosocial context of engagement that also includes their social networks. Important psychosocial factors drive women's medical decisions, such as individual feelings of guilt and vulnerability, and the degree of perceived social support. Women who felt guilty and fearful that they might pass the BRCA gene to their children were more likely to undergo risk reducing surgery. Women with at least one daughter and women without children were more inclined toward the risk reducing surgery compared to those with only sons. These psychosocial factors and social network engagements serve as a "nexus of decision making" that does not, for the most part, mirror the medical assessments of statistical odds for hereditary cancer development, nor the specific treatment protocols outlined by the medical establishment.

  2. Prevalence of Mantoux test positivity among apparently healthy ...

    African Journals Online (AJOL)

    Prevalence of Mantoux test positivity among apparently healthy children in Maiduguri, Nigeria. MG Mustapha, AM Garba, AI Rabasa, MS Gimba. Abstract. Background. The impact of tuberculosis (TB) is highest in the developing countries of Asia and Africa, especially among children, in whom the diagnosis is challenging.

  3. Prevalence and risk factors for cats testing positive for feline immunodeficiency virus and feline leukaemia virus infection in cats entering an animal shelter in New Zealand.

    Science.gov (United States)

    Gates, M C; Vigeant, S; Dale, A

    2017-11-01

    AIMS To estimate the prevalence of cats testing positive for antibodies to feline immunodeficiency virus (FIV) and feline leukaemia virus (FeLV) antigens in domestic cats entering a New Zealand animal shelter, based on a commercial point-of-care ELISA, to identify risk factors associated with cats testing positive, and to compare the results obtained from the ELISA with those obtained using PCR-based testing. METHOD A cross-sectional study was performed on 388 cats entering the Royal New Zealand Society for the Prevention of Cruelty to Animals animal shelter in Auckland, New Zealand between 7 February 2014 and 30 May 2014. Whole blood samples were collected from each cat and tested for FIV antibody and FeLV antigen using a commercial point-of-care ELISA. Information on the signalment and health status of the cat at the time of entry was also recorded. Blood and saliva samples from a subset of cats were tested for FIV and FeLV proviral DNA using a real-time PCR assay. RESULTS Of the 388 cats in the study sample, 146 (37.6%) had been relinquished by owners, 237 (62.4%) were strays, and 5 (1.3%) were of unknown origin. Overall, 53/388 (13.7%) cats tested positive for FIV antibodies and 4/388 (1.0%) were positive for FeLV antigen. Stray cats had a higher FIV seroprevalence than relinquished cats (42/237 (17.8%) vs. 11/146 (7.5%); p=0.008). Of 53 cats that were FIV-seropositive, 51 (96%) tested positive for FIV proviral DNA using PCR testing of blood. Of these 51 cats, 28 (55%) were positive by PCR testing of saliva. Of the four cats that were FeLV antigen-positive by ELISA, two (50%) were positive for FeLV proviral DNA by PCR testing of blood. The odds of a cat being seropositive for FIV were greater for intact compared to desexed cats (OR=3.3; 95% CI=1.6-7.4) and for male compared to female cats (OR=6.5; 95% CI=3.2-14.0). CONCLUSIONS AND CLINICAL RELEVANCE The seroprevalence for FIV was 14% among cats entering an animal shelter in Auckland, whereas the prevalence of

  4. Characteristics of children with positive tuberculin skin test.

    Science.gov (United States)

    Hocaoğlu, Arzu Babayiğit; Erge, Duygu Olmez; Anal, Ozden; Makay, Balahan; Uzuner, Nevin; Karaman, Ozkan

    2011-01-01

    The aim of the study was to define the characteristics of children with latent tuberculosis diagnosed with positive tuberculin skin test (TST) and evaluate potential risk factors in children with positive TST. Children followed with the diagnosis of latent tuberculosis infection were included in the study retrospectively. Demographic characteristics of patients including history of atopy, respiratory infections, family history of tuberculosis and atopy, number of BCG vaccinations, findings of physical examination and laboratory data were extracted from patient's file. Eighty-one children (51 male, 30 female) who had positive TST were retrospectively evaluated in the study. Mean age of the patients was 8.00 ± 4.00 years. Only 13 (16%) of the children had contact with a case who had active tuberculosis. It was shown that the age of the patients, number of BCG scars and BCG vaccination significantly affected TST reaction size. TST size was not affected with time passed after last dose of BCG vaccination, family history of tuberculosis, presence of TST positive case in the family, exposure to cigarette smoke, number of household family members and presence of respiratory allergic disease. The patient's age, numbers of BCG vaccination and BCG scars significantly affect TST results in childhood. This may cause difficulty in diagnosing latent tuberculosis infection and in decision of initiating prophylactic treatment. The results of this study may show that recently developed, more accurate and convenient in vitro tests that they have higher costs and require sophisticated laboratory, can be used to diagnose latent tuberculosis.

  5. On the Representativeness of Norming Samples for Aptitude Test

    National Research Council Canada - National Science Library

    Sims, William

    2003-01-01

    ...). We regressed aptitude test scores on demographics and concluded that: ̂ Norming sample for aptitude tests must be representative of the target population with respect to age, race"ethnicity, gender, respondent's education, and mother's...

  6. A novel PMT test system based on waveform sampling

    Science.gov (United States)

    Yin, S.; Ma, L.; Ning, Z.; Qian, S.; Wang, Y.; Jiang, X.; Wang, Z.; Yu, B.; Gao, F.; Zhu, Y.; Wang, Z.

    2018-01-01

    Comparing with the traditional test system based on a QDC and TDC and scaler, a test system based on waveform sampling is constructed for signal sampling of the 8"R5912 and the 20"R12860 Hamamatsu PMT in different energy states from single to multiple photoelectrons. In order to achieve high throughput and to reduce the dead time in data processing, the data acquisition software based on LabVIEW is developed and runs with a parallel mechanism. The analysis algorithm is realized in LabVIEW and the spectra of charge, amplitude, signal width and rising time are analyzed offline. The results from Charge-to-Digital Converter, Time-to-Digital Converter and waveform sampling are discussed in detailed comparison.

  7. Association between positive patch tests to epoxy resin and fragrance mix I ingredients

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Christensen, Lars Porskjaer; Vølund, Aage

    2009-01-01

    and possibly reproduce this association with the use of TRUE((R)) test data and supplementary tests with fragrance mix ingredients from the Department of Dermatology, Odense University Hospital. MATERIALS AND METHODS: Six thousand one hundred and fifteen consecutive eczema patients tested from 1995 to 2007......BACKGROUND: Both epoxy resin (diglycidyl ether of bisphenol A) and fragrance mix I are included in the European baseline series of contact allergens. A significant association between positive reactions to epoxy resin and fragrance mix has been reported by others. OBJECTIVE: To investigate...... were included, and test results from all patients tested with fragrance mix ingredients were analysed. RESULTS: One hundred and forty-five (2.4%) were positive to epoxy resin and 282 (4.6%) were positive to fragrance mix I. Nineteen were positive to both giving an odds ratio of 3.3, which...

  8. The Influence of Lying Body Position on Handwriting.

    Science.gov (United States)

    Dziedzic, Tomasz

    2016-01-01

    Although the problem of handwriting variability due to lying body position has practical significance, particularly for last will cases, it has not been sufficiently studied. The presented experiment aimed to recognize how such posture may influence handwriting features. Samples of text and signatures were collected from 50 healthy individuals, aged 23-58, produced in three postures: typical sitting position (SP) and two different lying positions (LP1 & LP2). Using the SP sample of each individual as a specimen, eleven characteristics in LP1 and LP2 samples were evaluated as similar or different. Nine other features were measured with a specialized software, and their conformity was tested with Student's t-test. Although none of the characteristics differed significantly in most cases, variation occurred in pen pressure, margins, baselines, and heights of letters. Additionally, a series of blind tests revealed that lying position of the individuals did not hinder the possibility to identify their writings. © 2015 American Academy of Forensic Sciences.

  9. Direct identification and susceptibility testing of positive blood cultures using high speed cold centrifugation and Vitek II system.

    Science.gov (United States)

    Bazzi, Ali M; Rabaan, Ali A; Fawarah, Mahmoud M; Al-Tawfiq, Jaffar A

    Compared to routine isolated colony-based methods, direct testing of bacterial pellets from positive blood cultures reduces turnaround time for reporting of antibiotic susceptibility. The aim of this study was to compare the accuracy, and precision, of a rapid method for direct identification and susceptibility testing of blood cultures with the routine method used in our laboratory, using Vitek 2. A total of 60 isolates were evaluated using the candidate and the routine method. The candidate method had 100% accuracy for the identification of Gram negative bacteria, Staphylococcus and Enterococcus, 50% for Streptococcus and 33.3% for Corynebacterium species. Susceptibility testing of Gram negative isolates yielded 98-100% essential agreement. For Staphylococcus and Enterococcus isolates, essential agreement was 100% for 17 antibiotics except for moxifloxacin. Direct testing of blood culture samples with Vitek 2 produced reliable identification and susceptibility results 18-24h sooner for aerobic/anaerobic facultative Gram-negative bacteria and Gram-positive Staphylococcus and Enterococcus strains. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  10. Commutability of food microbiology proficiency testing samples.

    Science.gov (United States)

    Abdelmassih, M; Polet, M; Goffaux, M-J; Planchon, V; Dierick, K; Mahillon, J

    2014-03-01

    Food microbiology proficiency testing (PT) is a useful tool to assess the analytical performances among laboratories. PT items should be close to routine samples to accurately evaluate the acceptability of the methods. However, most PT providers distribute exclusively artificial samples such as reference materials or irradiated foods. This raises the issue of the suitability of these samples because the equivalence-or 'commutability'-between results obtained on artificial vs. authentic food samples has not been demonstrated. In the clinical field, the use of noncommutable PT samples has led to erroneous evaluation of the performances when different analytical methods were used. This study aimed to provide a first assessment of the commutability of samples distributed in food microbiology PT. REQUASUD and IPH organized 13 food microbiology PTs including 10-28 participants. Three types of PT items were used: genuine food samples, sterile food samples and reference materials. The commutability of the artificial samples (reference material or sterile samples) was assessed by plotting the distribution of the results on natural and artificial PT samples. This comparison highlighted matrix-correlated issues when nonfood matrices, such as reference materials, were used. Artificially inoculated food samples, on the other hand, raised only isolated commutability issues. In the organization of a PT-scheme, authentic or artificially inoculated food samples are necessary to accurately evaluate the analytical performances. Reference materials, used as PT items because of their convenience, may present commutability issues leading to inaccurate penalizing conclusions for methods that would have provided accurate results on food samples. For the first time, the commutability of food microbiology PT samples was investigated. The nature of the samples provided by the organizer turned out to be an important factor because matrix effects can impact on the analytical results. © 2013

  11. Tracer gas diffusion sampling test plan

    International Nuclear Information System (INIS)

    Rohay, V.J.

    1993-01-01

    Efforts are under way to employ active and passive vapor extraction to remove carbon tetrachloride from the soil in the 200 West Area an the Hanford Site as part of the 200 West Area Carbon Tetrachloride Expedited Response Action. In the active approach, a vacuum is applied to a well, which causes soil gas surrounding the well to be drawn up to the surface. The contaminated air is cleaned by passage through a granular activated carbon bed. There are questions concerning the radius of influence associated with application of the vacuum system and related uncertainties about the soil-gas diffusion rates with and without the vacuum system present. To address these questions, a series of tracer gas diffusion sampling tests is proposed in which an inert, nontoxic tracer gas, sulfur hexafluoride (SF 6 ), will be injected into a well, and the rates of SF 6 diffusion through the surrounding soil horizon will be measured by sampling in nearby wells. Tracer gas tests will be conducted at sites very near the active vacuum extraction system and also at sites beyond the radius of influence of the active vacuum system. In the passive vapor extraction approach, barometric pressure fluctuations cause soil gas to be drawn to the surface through the well. At the passive sites, the effects of barometric ''pumping'' due to changes in atmospheric pressure will be investigated. Application of tracer gas testing to both the active and passive vapor extraction methods is described in the wellfield enhancement work plan (Rohay and Cameron 1993)

  12. Evaluation of human papillomavirus detection by Abbott m2000 system on samples collected by FTA Elute™ Card in a Chinese HIV-1 positive population.

    Science.gov (United States)

    Qin, Yu; Zhang, Hongyun; Marlowe, Natalia; Fei, Mandong; Yu, Judy; Lei, Xiaoqin; Yu, Lulu; Zhang, Jia; Cao, Di; Ma, Li; Chen, Wen

    2016-12-01

    HIV+/AIDS women have an increased risk of developing into CIN and cervical cancer compared to the general population. Limited medical resource and the lack of AIDS relevant knowledge impair the coverage and efficiency of cervical cancer screening. To compare the clinical performance of self-collected dry storage medium (FTA Elute card) and physician-collected PreservCyt medium in detection of high risk human papillomavirus (HR HPV) among HIV-1 positive population. Three hundred HIV-1 positive women (aged 25-65) were recruited from Yunnan infectious hospital. Two cervicovaginal samples were collected from each participant: one was collected by the women themselves and applied on a FTA Elute card; the other one was collected by a physician and stored in PreservCyt solution. All the samples were tested for 14 HR HPV using Abbott RealTime High Risk HPV assay. Biopsies were taken for histological diagnosis if any abnormal impression was noticed under colposcopy. 291 (97.0%) of participants were eligible for this study. 101 (34.70%) participants were found HR HPV positive in both FTA card and PreservCyt samples, and 19 (6.53%) women were diagnosed as CIN2+. The HR HPV positive rate on samples collected by FTA Elute card and PreservCyt solution was 42.61% and 39.86%, respectively. The overall agreement was 87% (kappa=0.731) between FTA card and PreservCyt. The clinical sensitivity and specificity of FTA card and PreservCyt were 100%, 61.39% and 100%, 64.33%, respectively. In this study, FTA Elute card demonstrated a good performance on self-collected sample for HR HPV detection in HIV-1 positive population. For the women from low-resource area with HIV-1 infection, FTA Elute card could be an attractive sample collection method for cervical cancer screening. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Women’s experience with home-based self-sampling for human papillomavirus testing

    International Nuclear Information System (INIS)

    Sultana, Farhana; Mullins, Robyn; English, Dallas R.; Simpson, Julie A.; Drennan, Kelly T.; Heley, Stella; Wrede, C. David; Brotherton, Julia M. L.; Saville, Marion; Gertig, Dorota M.

    2015-01-01

    Increasing cervical screening coverage by reaching inadequately screened groups is essential for improving the effectiveness of cervical screening programs. Offering HPV self-sampling to women who are never or under-screened can improve screening participation, however participation varies widely between settings. Information on women’s experience with self-sampling and preferences for future self-sampling screening is essential for programs to optimize participation. The survey was conducted as part of a larger trial (“iPap”) investigating the effect of HPV self-sampling on participation of never and under-screened women in Victoria, Australia. Questionnaires were mailed to a) most women who participated in the self-sampling to document their experience with and preference for self-sampling in future, and b) a sample of the women who did not participate asking reasons for non-participation and suggestions for enabling participation. Reasons for not having a previous Pap test were also explored. About half the women who collected a self sample for the iPap trial returned the subsequent questionnaire (746/1521). Common reasons for not having cervical screening were that having Pap test performed by a doctor was embarrassing (18 %), not having the time (14 %), or that a Pap test was painful and uncomfortable (11 %). Most (94 %) found the home-based self-sampling less embarrassing, less uncomfortable (90 %) and more convenient (98 %) compared with their last Pap test experience (if they had one); however, many were unsure about the test accuracy (57 %). Women who self-sampled thought the instructions were clear (98 %), it was easy to use the swab (95 %), and were generally confident that they did the test correctly (81 %). Most preferred to take the self-sample at home in the future (88 %) because it was simple and did not require a doctor’s appointment. Few women (126/1946, 7 %) who did not return a self-sample in the iPap trial returned the questionnaire

  14. Position Angle Changes of Inner-Jets in a Sample of Blazars Ligong ...

    Indian Academy of Sciences (India)

    Position Angle Changes of Inner-Jets in a Sample of Blazars. Ligong Mi1,3,∗ & Xiang Liu1,2. 1Xinjiang Astronomical Observatory, CAS, 150 Science 1-Street, Urumqi 830011,. People's Republic of China. 2Key Laboratory of Radio Astronomy, CAS, Nanjing 210008, People's Republic of China. 3University of Chinese ...

  15. Test plan for the Sample Transfer Canister system

    International Nuclear Information System (INIS)

    Flanagan, B.D.

    1998-01-01

    The Sample Transfer Canister will be used by the Waste Receiving and Processing Facility (WRAP) for the transport of small quantity liquid samples that meet the definition of a limited quantity radioactive material, and may also be corrosive and/or flammable. These samples will be packaged and shipped in accordance with the US Department of Transportation (DOT) regulation 49 CFR 173.4, ''Exceptions for small quantities.'' The Sample Transfer Canister is of a ''French Can'' design, intended to be mated with a glove box for loading/unloading. Transport will typically take place north of the Wye Barricade between WRAP and the 222-S Laboratory. The Sample Transfer Canister will be shipped in an insulated ice chest, but the ice chest will not be a part of the small quantity package during prototype testing

  16. Internal Impingement of the Shoulder: A Risk of False Positive Test Outcomes in External Impingement Tests?

    Directory of Open Access Journals (Sweden)

    Tim Leschinger

    2017-01-01

    Full Text Available Background. External impingement tests are considered as being particularly reliable for identifying subacromial and coracoid shoulder impingement mechanisms. The purpose of the present study was to evaluate if these tests are likely to provoke an internal shoulder impingement mechanism which, in cases of a pathologic condition, can lead to a positive test result. Method. In 37 subjects, the mechanical contact between the glenoid rim and the rotator cuff (RC was measured quantitatively and qualitatively in external impingement test positions using an open MRI system. Results. Mechanical contact of the supraspinatus with the posterosuperior glenoid was present in 30 subjects in the Neer test. In the Hawkins test, the subscapularis was in contact with the anterosuperior glenoid in 33 subjects and the supraspinatus in 18. In the horizontal impingement test, anterosuperior contact of the supraspinatus with the glenoid was identified in 35 subjects. Conclusion. The Neer, Hawkins, and horizontal impingement tests are likely to provoke the mechanism of an internal shoulder impingement. A posterosuperior internal impingement mechanism is being provoked predominately in the Neer test. The Hawkins test narrows the distance between the insertions of the subscapularis and supraspinatus and the anterosuperior labrum, which leads to an anterosuperior impingement mechanism.

  17. The relationship between personalities and self-report positive driving behavior in a Chinese sample

    Science.gov (United States)

    Sun, Xianghong; Zhang, Kan

    2018-01-01

    Driving behaviors play an important role in accident involvement. Concretely speaking, aberrant driving behaviors would cause more accidents, and oppositely positive driving behaviors would promote to build safety traffic environment. The main goals of this study were to explore the positive driving behavior and its relationship with personality in a Chinese sample. A total of 421 licensed drivers (286 male and 135 female) from Beijing, China completed the Positive Driver Behavior Scale (PDBS), the Driver Behavior Questionnaire (DBQ), the Dula Dangerous Driving Index (DDDI) and the Big Five Inventory (BFI) on a voluntary and anonymous basis. The results showed that the Chinese version of the PDBS has both reliability and validity and that the PDBS was significantly correlated with the BFI. Specifically, the PDBS was negatively correlated with neuroticism (r = -0.38) and positively correlated with extraversion, agreeableness, conscientiousness and openness to experience (the correlation coefficient ranged from 0.36 to 0.55). In contrast with previous research, age was negatively correlated with the PDBS (r = -0.38) in our sample, which may have resulted from less driving experience or a lack of available cognitive resources. PMID:29324823

  18. The relationship between personalities and self-report positive driving behavior in a Chinese sample.

    Directory of Open Access Journals (Sweden)

    Biying Shen

    Full Text Available Driving behaviors play an important role in accident involvement. Concretely speaking, aberrant driving behaviors would cause more accidents, and oppositely positive driving behaviors would promote to build safety traffic environment. The main goals of this study were to explore the positive driving behavior and its relationship with personality in a Chinese sample. A total of 421 licensed drivers (286 male and 135 female from Beijing, China completed the Positive Driver Behavior Scale (PDBS, the Driver Behavior Questionnaire (DBQ, the Dula Dangerous Driving Index (DDDI and the Big Five Inventory (BFI on a voluntary and anonymous basis. The results showed that the Chinese version of the PDBS has both reliability and validity and that the PDBS was significantly correlated with the BFI. Specifically, the PDBS was negatively correlated with neuroticism (r = -0.38 and positively correlated with extraversion, agreeableness, conscientiousness and openness to experience (the correlation coefficient ranged from 0.36 to 0.55. In contrast with previous research, age was negatively correlated with the PDBS (r = -0.38 in our sample, which may have resulted from less driving experience or a lack of available cognitive resources.

  19. The relationship between personalities and self-report positive driving behavior in a Chinese sample.

    Science.gov (United States)

    Shen, Biying; Qu, Weina; Ge, Yan; Sun, Xianghong; Zhang, Kan

    2018-01-01

    Driving behaviors play an important role in accident involvement. Concretely speaking, aberrant driving behaviors would cause more accidents, and oppositely positive driving behaviors would promote to build safety traffic environment. The main goals of this study were to explore the positive driving behavior and its relationship with personality in a Chinese sample. A total of 421 licensed drivers (286 male and 135 female) from Beijing, China completed the Positive Driver Behavior Scale (PDBS), the Driver Behavior Questionnaire (DBQ), the Dula Dangerous Driving Index (DDDI) and the Big Five Inventory (BFI) on a voluntary and anonymous basis. The results showed that the Chinese version of the PDBS has both reliability and validity and that the PDBS was significantly correlated with the BFI. Specifically, the PDBS was negatively correlated with neuroticism (r = -0.38) and positively correlated with extraversion, agreeableness, conscientiousness and openness to experience (the correlation coefficient ranged from 0.36 to 0.55). In contrast with previous research, age was negatively correlated with the PDBS (r = -0.38) in our sample, which may have resulted from less driving experience or a lack of available cognitive resources.

  20. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme.

    Directory of Open Access Journals (Sweden)

    Espen Enerly

    Full Text Available Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP, 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1% hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway.

  1. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme.

    Science.gov (United States)

    Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway.

  2. The first DC performance test and analysis of CC conductor short sample at ASIPP conductor test facility

    International Nuclear Information System (INIS)

    Shi Yi; Wu Yu; Liu Huajun; Long Feng; Qian Li; Ren Zhibin; Li Shaolei; Liu Bo; Chen Jinglin

    2012-01-01

    Highlights: ► In this study the first DC performance experiments of ITER correction coil conductor short sample have been carried out in ASIPP test facility. ► A CC conductor short sample was fabricated and tested to confirm the capability of this test facility for qualification tests of CC conductors. ► There is no obvious impact of cycling on DC performance measurement. ► Those measured results of current sharing temperature are in agreement with the expected results from strand scaling - Abstract: The first DC performance experiments of ITER correction coil (CC) conductor short sample have been carried out in the conductor test facility of Institute of Plasma Physics, CAS (ASIPP) in January this year. Those experiments aim to investigate the DC performance of ITER CC conductor. The tested conductor short sample is bended as a half circle with the diameter of 270 mm to meet the background magnetic field shape. The half circle part of sample is longer than the final twist pitch. The current sharing temperature (T cs ) in the 3.86 T external magnetic field (B ex ), ≤12 kA could be measured including the critical current (I c ) run. There is no obvious impact of 1000 cycles on DC performance. Those measured T cs results are in agreement with the expected results from strand scaling.

  3. Effect of Positive Training on Positive Psychological States (Character Strengths of Female High School Students

    Directory of Open Access Journals (Sweden)

    Ali Farnam

    2017-05-01

    Full Text Available psychological states of female students in second and third grades of high school. The research method was quasi-experimental with pre-test, post-test and follow-up. The sample consisted of forty students selected randomly in two groups (twenty students in each group. To collect data, Positive Psychological State Inventory (Rajaei, Khuy Nzhad and Nesaei was used. The experimental group received ninety minute positive training sessions (for two months and the control group did not receive treatment. The results of analysis  of covariance showed that positive training had positive effects on positive psychological states (trust in God, optimism, self-efficacy, duty, sense of control, targeted, hope, satisfaction with life, meaningful life, pleasant, sociability, self-esteem and self-worth, sense of peace, gratitude, and forgiveness among adolescents  both in the post  and follow-up tests

  4. Laboratory Tests of Bitumen Samples Elasticity

    Science.gov (United States)

    Ziganshin, E. R.; Usmanov, S. A.; Khasanov, D. I.; Khamidullina, G. S.

    2018-05-01

    This paper is devoted to the study of the elastic and acoustic properties of bitumen core samples. The travel velocities of the ultrasonic P- and S-waves were determined under in-situ simulation conditions. The resulting data were then used to calculate dynamic Young's modulus and Poisson's ratio. The authors studied the correlation between the elasticity and the permeability and porosity. In addition, the tests looked into how the acoustic properties had changed with temperature rise.

  5. HCV knowledge among a sample of HCV positive Aboriginal Australians residing in New South Wales.

    Science.gov (United States)

    Wilson, Hannah; Brener, Loren; Jackson, L Clair; Saunders, Veronica; Johnson, Priscilla; Treloar, Carla

    2017-06-01

    Australian Aboriginal and Torres Strait Islanders are overrepresented in both the prevalence and incidence of the hepatitis C (HCV). HCV knowledge has been associated with a range of positive health behaviours. HCV knowledge has previously been investigated as a single construct; however examining different knowledge domains (i.e. transmission, risk of complications, testing and treatment) separately may be beneficial. This study investigated whether having greater HCV knowledge in different domains is associated with self-reported positive health behaviours. 203 Aboriginal people living with HCV completed a survey assessing HCV knowledge, testing and care, lifestyle changes since diagnosis and treatment intent. Respondents' knowledge was relatively high. Greater knowledge of risk of health complications was associated with undertaking more positive lifestyle changes since diagnosis. Respondents testing and treatment knowledge was significantly associated with incarceration, lifestyle changes since diagnosis and future treatment intentions. This study illustrates the importance of ensuring that knowledge is high across different HCV domains to optimise a range of positive health behaviours of Aboriginal people living with HCV. Future health promotion campaigns targeted at Aboriginal people living with HCV could benefit from broadening their focus from prevention to other domains such as testing and treatment.

  6. Measuring use of positive thinking skills: psychometric testing of a new scale.

    Science.gov (United States)

    Bekhet, Abir K; Zauszniewski, Jaclene A

    2013-09-01

    Positive thinking interventions improve adaptive functioning and quality of life in many populations. However, no direct measure of positive thinking skills taught during intervention exists. This psychometric study of a convenience sample of 109 autism spectrum disorder (ASD) caregivers examined a new eight-item Positive Thinking Skills Scale (PTSS), which measures the frequency of use of positive thinking skills. The PTSS was found to be internally consistent (α = .90). Construct validity was supported by significant correlations (p thinking skills could provide direction for future intervention.

  7. Transfer of test samples and wastes between post-irradiation test facilities (FMF, AGF, MMF)

    International Nuclear Information System (INIS)

    Ishida, Yasukazu; Suzuki, Kazuhisa; Ebihara, Hikoe; Matsushima, Yasuyoshi; Kashiwabara, Hidechiyo

    1975-02-01

    Wide review is given on the problems associated with the transfer of test samples and wastes between post-irradiation test facilities, FMF (Fuel Monitoring Facility), AGF (Alpha Gamma Facility), and MMF (Material Monitoring Facility) at the Oarai Engineering Center, PNC. The test facilities are connected with the JOYO plant, an experimental fast reactor being constructed at Oarai. As introductory remarks, some special features of transferring irradiated materials are described. In the second part, problems on the management of nuclear materials and radio isotopes are described item by item. In the third part, the specific materials that are envisaged to be transported between JOYO and the test facilities are listed together with their geometrical shapes, dimensions, etc. In the fourth part, various routes and methods of transportation are explained with many block charts and figures. Brief explanation with lists and drawings is also given to transportation casks and vessels. Finally, some future problems are discussed, such as the prevention of diffusive contamination, ease of decontamination, and the identification of test samples. (Aoki, K.)

  8. In-Pipe Wireless Communication for Underground Sampling and Testing

    NARCIS (Netherlands)

    Nguyen, Nhan D.T.; Le, Duc V.; Meratnia, Nirvana; Havinga, Paul J.M.

    2017-01-01

    In this paper, we present an effective and low- cost wireless communication system for extremely long and narrow pipes that can replay the extant wire system in underground sensor network applications such as soil sampling and testing with the Cone Penetration Test (CPT), the most widely used

  9. Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samples.

    Science.gov (United States)

    Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J

    2016-06-01

    The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  10. Test plan for K Basin Sludge Canister and Floor Sampling Device

    International Nuclear Information System (INIS)

    Meling, T.A.

    1995-01-01

    This document provides the test plan and procedure forms for conducting the functional and operational acceptance testing of the K Basin Sludge Canister and Floor Sampling Device(s). These samplers samples sludge off the floor of the 100K Basins and out of 100K fuel storage canisters

  11. Impact of grey zone sample testing by enzyme-linked immunosorbent assay in enhancing blood safety: Experience at a tertiary care hospital in North India.

    Science.gov (United States)

    Solanki, Archana; Singh, Abhay; Chaudhary, Rajendra

    2016-01-01

    Enzyme-linked immunosorbent assay (ELISA) used for screening blood donors for transfusion transmitted infections (TTIs) can sometimes fail to detect blood donors who are recently infected or possessing the low strength of pathogen. Estimation of a grey zone in ELISA testing and repeat testing of grey zone samples can further help in reducing the risks of TTI in countries where nucleic acid amplification testing for TTIs is not feasible. Grey zone samples with optical density (OD) lying between cut-off OD and 10% below the cut-off OD (cut-off OD × 0.9) were identified during routine ELISA testing. On performing repeat ELISA testing on grey zone samples in duplicate, the samples showing both OD value below grey zone were marked nonreactive, and samples showing one or both OD value in the grey zone were marked indeterminate. The samples on repeat testing showing one or both OD above cut-off value were marked positive. About 119 samples (77 for hepatitis B virus [HBV], 23 for human immunodeficiency virus [HIV], and 19 for hepatitis C virus [HCV]) were found to be in grey zone. On repeat testing of these samples in duplicate, 70 (58.8%) samples (45 for HBV, 12 for HIV, and 13 for HCV) were found to be reactive. Six (5%) samples (four for HBV, one for HIV, and one for HCV) were found to be indeterminate. Seventy donors initially screened negative, were found out to be potentially infectious on repeat grey zone testing. Thus, estimation of grey zone samples with repeat testing can further enhance the safety of blood transfusion.

  12. The Bootstrap, the Jackknife, and the Randomization Test: A Sampling Taxonomy.

    Science.gov (United States)

    Rodgers, J L

    1999-10-01

    A simple sampling taxonomy is defined that shows the differences between and relationships among the bootstrap, the jackknife, and the randomization test. Each method has as its goal the creation of an empirical sampling distribution that can be used to test statistical hypotheses, estimate standard errors, and/or create confidence intervals. Distinctions between the methods can be made based on the sampling approach (with replacement versus without replacement) and the sample size (replacing the whole original sample versus replacing a subset of the original sample). The taxonomy is useful for teaching the goals and purposes of resampling schemes. An extension of the taxonomy implies other possible resampling approaches that have not previously been considered. Univariate and multivariate examples are presented.

  13. Advantages of analyzing postmortem brain samples in routine forensic drug screening—case series of three non-natural deaths tested positive for lysergic acid diethylamide (LSD)

    DEFF Research Database (Denmark)

    Mardal, Marie; Johansen, Sys Stybe; Thomsen, Ragnar

    2017-01-01

    Three case reports are presented, including autopsy findings and toxicological screening results, which were tested positive for the potent hallucinogenic drug lysergic acid diethylamide (LSD). LSD and its main metabolites were quantified in brain tissue and femoral blood, and furthermore hematoma...

  14. Specificity and false positive rates of the Test of Memory Malingering, Rey 15-item Test, and Rey Word Recognition Test among forensic inpatients with intellectual disabilities.

    Science.gov (United States)

    Love, Christopher M; Glassmire, David M; Zanolini, Shanna Jordan; Wolf, Amanda

    2014-10-01

    This study evaluated the specificity and false positive (FP) rates of the Rey 15-Item Test (FIT), Word Recognition Test (WRT), and Test of Memory Malingering (TOMM) in a sample of 21 forensic inpatients with mild intellectual disability (ID). The FIT demonstrated an FP rate of 23.8% with the standard quantitative cutoff score. Certain qualitative error types on the FIT showed promise and had low FP rates. The WRT obtained an FP rate of 0.0% with previously reported cutoff scores. Finally, the TOMM demonstrated low FP rates of 4.8% and 0.0% on Trial 2 and the Retention Trial, respectively, when applying the standard cutoff score. FP rates are reported for a range of cutoff scores and compared with published research on individuals diagnosed with ID. Results indicated that although the quantitative variables on the FIT had unacceptably high FP rates, the TOMM and WRT had low FP rates, increasing the confidence clinicians can place in scores reflecting poor effort on these measures during ID evaluations. © The Author(s) 2014.

  15. False-positive Human Papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Lynge, Elsebeth

    2011-01-01

    Based on data from randomised controlled trials (RCT) on primary cervical screening, it has been reported that the problem of more frequent false-positive tests in Human Papillomavirus (HPV) DNA screening compared to cytology could be overcome. However, these reports predominantly operated...

  16. Gas liquid sampling for closed canisters in KW Basin - test plan

    International Nuclear Information System (INIS)

    Pitkoff, C.C.

    1995-01-01

    Test procedures for the gas/liquid sampler. Characterization of the Spent Nuclear Fuel, SNF, sealed in canisters at KW-Basin is needed to determine the state of storing SNF wet. Samples of the liquid and the gas in the closed canisters will be taken to gain characterization information. Sampling equipment has been designed to retrieve gas and liquid from the closed canisters in KW basin. This plan is written to outline the test requirements for this developmental sampling equipment

  17. 21 CFR 864.3260 - OTC test sample collection systems for drugs of abuse testing.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false OTC test sample collection systems for drugs of abuse testing. 864.3260 Section 864.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology...

  18. Experimental Investigation Of Microbially Induced Corrosion Of Test Samples And Effect Of Self-assembled Hydrophobic Monolayers. Exposure Of Test Samples To Continuous Microbial Cultures, Chemical Analysis, And Biochemical Studies

    CERN Document Server

    Laurinavichius, K S

    1998-01-01

    Experimental Investigation Of Microbially Induced Corrosion Of Test Samples And Effect Of Self-assembled Hydrophobic Monolayers. Exposure Of Test Samples To Continuous Microbial Cultures, Chemical Analysis, And Biochemical Studies

  19. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of ... Conclusion: Acceptability of self-sampling for HPV testing was similarly excellent in both groups despite their difference in terms ... cancer is the leading cause of death caused by cancer in.

  20. Cooperative testing of a positive personnel identifier

    International Nuclear Information System (INIS)

    O'Callaghan, P.B.; Grambihler, A.J.; Graham, D.K.; Bradley, R.G.

    1980-06-01

    HEDL has a requirement to ensure the identification of remote computer terminal operators on a real-time nuclear inventory data base. The integrity of this data base depends on input from authorized individuals. Thus, a key to developing such a system is the ability to positively identify people attempting access to the system. Small scale tests of the Identimat 2000T hand geometry unit with an adjusting alogrithm have suggested a promising solution. To prove operational suitability, HEDL, in cooperation with Sandia Laboratories, has designed a large scale test of the Identimat 2000T. Data gathering on error rates, reliability, maintainability, and user acceptance will determine if the Identimat 2000T is suitable for the HEDL application. If proven acceptable, use of the Identimat 2000T can be broadened to many general applications where security information, locations and systems are required

  1. Genetic Testing for Wolfram Syndrome Mutations in a Sample of 71 Patients with Hereditary Optic Neuropathy and Negative Genetic Test Results for OPA1/OPA3/LHON.

    Science.gov (United States)

    Galvez-Ruiz, Alberto; Galindo-Ferreiro, Alicia; Schatz, Patrik

    2018-04-01

    In this study, the authors present a sample of 71 patients with hereditary optic neuropathy and negative genetic test results for OPA1/OPA3/LHON. All of these patients later underwent genetic testing to rule out WFS. As a result, 53 patients (74.7%) were negative and 18 patients (25.3%) were positive for some type of mutation or variation in the WFS gene. The authors believe that this study is interesting because it shows that a sizeable percentage (25.3%) of patients with hereditary optic 25 neuropathy and negative genetic test results for OPA1/OPA3/LHON had WFS mutations or variants.

  2. Fatigue testing on samples from Zircaloy-4 tubes type SEU-43

    International Nuclear Information System (INIS)

    Olaru, V.; Ionescu, V.; Nitu, A.; Ionescu, D.; Voicu, F.

    2016-01-01

    The paper presents the testing of samples worked from Zicaloy-4 tubes (as-received.. metallurgical state), utilized in the composition of the CANDU SEU-43 fuel bundle. These tests are intended to simulate their behaviour in a power cycling process inside the reactor. The testing process is of low cycle fatigue type, done outside of the reactor, on ''C-ring'' samples, cut along the transversal direction. These samples are tested at 1%, 2% and 3% amplitude deformation, at room temperature. The calibration curves for both types of tube (small and big diameter) are determined by using the finite element analyses with the ANSYS computer code. The cycling test results are in the form of a fatigue life curve (N-e) for zircaloy-4 used in the SEU-43 fuel bundle. The curve is determined by the experimental dependency between the number of cycles to fracture and the deformation amplitude. The low cycle fatigue mechanical tests done at room temperature together with electronic microscopy analyses have reflected the characteristic behaviour of the zircaloy-4 metal in the given environment conditions. (authors)

  3. Microbial identification and automated antibiotic susceptibility testing directly from positive blood cultures using MALDI-TOF MS and VITEK 2.

    Science.gov (United States)

    Wattal, C; Oberoi, J K

    2016-01-01

    The study addresses the utility of Matrix Assisted Laser Desorption/Ionisation Time-Of-Flight mass spectrometry (MALDI-TOF MS) using VITEK MS and the VITEK 2 antimicrobial susceptibility testing (AST) system for direct identification (ID) and timely AST from positive blood culture bottles using a lysis-filtration method (LFM). Between July and December 2014, a total of 140 non-duplicate mono-microbial blood cultures were processed. An aliquot of positive blood culture broth was incubated with lysis buffer before the bacteria were filtered and washed. Micro-organisms recovered from the filter were first identified using VITEK MS and its suspension was used for direct AST by VITEK 2 once the ID was known. Direct ID and AST results were compared with classical methods using solid growth. Out of the 140 bottles tested, VITEK MS resulted in 70.7 % correct identification to the genus and/ or species level. For the 103 bottles where identification was possible, there was agreement in 97 samples (94.17 %) with classical culture. Compared to the routine method, the direct AST resulted in category agreement in 860 (96.5 %) of 891 bacteria-antimicrobial agent combinations tested. The results of direct ID and AST were available 16.1 hours before those of the standard approach on average. The combined use of VITEK MS and VITEK 2 directly on samples from positive blood culture bottles using a LFM technique can result in rapid and reliable ID and AST results in blood stream infections to result in early institution of targeted treatment. The combination of LFM and AST using VITEK 2 was found to expedite AST more reliably.

  4. Positive hepatitis B surface antigen tests due to recent vaccination: a persistent problem

    Directory of Open Access Journals (Sweden)

    Rysgaard Carolyn D

    2012-09-01

    Full Text Available Abstract Background Hepatitis B virus (HBV is a common cause of viral hepatitis with significant health complications including cirrhosis and hepatocellular carcinoma. Assays for hepatitis B surface antigen (HBsAg are the most frequently used tests to detect HBV infection. Vaccination for HBV can produce transiently detectable levels of HBsAg in patients. However, the time course and duration of this effect is unclear. The objective of this retrospective study was to clarify the frequency and duration of transient HBsAg positivity following vaccination against HBV. Methods The electronic medical record at an academic tertiary care medical center was searched to identify all orders for HBsAg within a 17 month time period. Detailed chart review was performed to identify all patients who were administered HBV vaccine within 180 days prior to HBsAg testing and also to ascertain likely cause of weakly positive (grayzone results. Results During the 17 month study period, 11,719 HBsAg tests were ordered on 9,930 patients. There were 34 tests performed on 34 patients who received HBV vaccine 14 days or less prior to HBsAg testing. Of these 34 patients, 11 had grayzone results for HBsAg that could be attributed to recent vaccination. Ten of the 11 patients were renal dialysis patients who were receiving HBsAg testing as part of routine and ongoing monitoring. Beyond 14 days, there were no reactive or grayzone HBsAg tests that could be attributed to recent HBV vaccination. HBsAg results reached a peak COI two to three days following vaccination before decaying. Further analysis of all the grayzone results within the 17 month study period (43 results out of 11,719 tests revealed that only 4 of 43 were the result of true HBV infection as verified by confirmatory testing. Conclusions Our study confirms that transient HBsAg positivity can occur in patients following HBV vaccination. The results suggest this positivity is unlikely to persist beyond 14 days

  5. Sensitivity Range Analysis of Infrared (IR) Transmitter and Receiver Sensor to Detect Sample Position in Automatic Sample Changer

    International Nuclear Information System (INIS)

    Syirrazie Che Soh; Nolida Yussup; Nur Aira Abdul Rahman; Maslina Ibrahim

    2016-01-01

    Sensitivity range of IR Transmitter and Receiver Sensor influences the effectiveness of the sensor to detect position of a sample. Then the purpose of this analysis is to determine the suitable design and specification the electronic driver of the sensor to gain appropriate sensitivity range for required operation. The related activities to this analysis cover electronic design concept and specification, calibration of design specification and evaluation on design specification for required application. (author)

  6. Testing of candidate non-lethal sampling methods for detection of Renibacterium salmoninarum in juvenile Chinook salmon Oncorhynchus tshawytscha

    Science.gov (United States)

    Elliott, Diane G.; McKibben, Constance L.; Conway, Carla M.; Purcell, Maureen K.; Chase, Dorothy M.; Applegate, Lynn M.

    2015-01-01

    Non-lethal pathogen testing can be a useful tool for fish disease research and management. Our research objectives were to determine if (1) fin clips, gill snips, surface mucus scrapings, blood draws, or kidney biopsies could be obtained non-lethally from 3 to 15 g Chinook salmon Oncorhynchus tshawytscha, (2) non-lethal samples could accurately discriminate between fish exposed to the bacterial kidney disease agent Renibacterium salmoninarum and non-exposed fish, and (3) non-lethal samples could serve as proxies for lethal kidney samples to assess infection intensity. Blood draws and kidney biopsies caused ≥5% post-sampling mortality (Objective 1) and may be appropriate only for larger fish, but the other sample types were non-lethal. Sampling was performed over 21 wk following R. salmoninarum immersion challenge of fish from 2 stocks (Objectives 2 and 3), and nested PCR (nPCR) and real-time quantitative PCR (qPCR) results from candidate non-lethal samples were compared with kidney tissue analysis by nPCR, qPCR, bacteriological culture, enzyme-linked immunosorbent assay (ELISA), fluorescent antibody test (FAT) and histopathology/immunohistochemistry. R. salmoninarum was detected by PCR in >50% of fin, gill, and mucus samples from challenged fish. Mucus qPCR was the only non-lethal assay exhibiting both diagnostic sensitivity and specificity estimates >90% for distinguishing between R. salmoninarum-exposed and non-exposed fish and was the best candidate for use as an alternative to lethal kidney sample testing. Mucus qPCR R. salmoninarum quantity estimates reflected changes in kidney bacterial load estimates, as evidenced by significant positive correlations with kidney R. salmoninaruminfection intensity scores at all sample times and in both fish stocks, and were not significantly impacted by environmentalR. salmoninarum concentrations.

  7. A prospective study of the psychosocial impact of a positive Chlamydia trachomatis laboratory test.

    Science.gov (United States)

    Gottlieb, Sami L; Stoner, Bradley P; Zaidi, Akbar A; Buckel, Christina; Tran, Molly; Leichliter, Jami S; Berman, Stuart M; Markowitz, Lauri E

    2011-11-01

    Few data exist on potential harms of chlamydia screening. We assessed the psychosocial impact of receiving a positive Chlamydia trachomatis test result. We prospectively studied women ≥16 years of age undergoing chlamydia testing in 2 Midwestern family planning clinics. We surveyed women at baseline and about 1 month after receiving test results, using 9 validated psychosocial scales/subscales and chlamydia-specific questions. Changes in scale scores were calculated for each woman. Mean percent changes in scores for chlamydia-positive and -negative women were compared using a t test. We enrolled 1807 women (response rate, 84%). Of the 1688 women with test results, 149 (8.8%) tested positive. At follow-up, chlamydia-positive women (n = 71) had a 75% increase in anxiety about sexual aspects of their life on the Multidimensional Sexual Self-Concept Questionnaire (P < 0.001), significantly greater than the 26% increase among 280 randomly selected chlamydia-negative women (P = 0.02). There were no differences for the other 8 scales/subscales, including general measures of anxiety, depression, and self-esteem. Chlamydia-positive women were more likely than chlamydia-negative women to be "concerned about chlamydia" (80% vs. 40%, P < 0.001) and to report breaking up with a main partner (33% vs. 11%, P < 0.001) at follow-up. Women testing positive reported a range of chlamydia-specific concerns. Chlamydia-positive women had significant increases in anxiety about sex and concern about chlamydia, but did not have marked changes in more general measures of psychosocial well-being about 1 month after diagnosis. Chlamydia diagnoses were associated with some disruption of relationships with main partners. Chlamydia-specific concerns may guide counseling messages to minimize psychosocial impact.

  8. Solubility testing of actinides on breathing-zone and area air samples

    International Nuclear Information System (INIS)

    Metzger, R.L.; Jessop, B.H.; McDowell, B.L.

    1996-02-01

    A solubility testing method for several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALS reg-sign) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of U 3 O 8 . Profiles developed for U 3 O 8 samples show good agreement with in vitro and in vivo tests performed by other investigators on samples from the same uranium mills

  9. Compressive and Flexural Tests on Adobe Samples Reinforced with Wire Mesh

    Science.gov (United States)

    Jokhio, G. A.; Al-Tawil, Y. M. Y.; Syed Mohsin, S. M.; Gul, Y.; Ramli, N. I.

    2018-03-01

    Adobe is an economical, naturally available, and environment friendly construction material that offers excellent thermal and sound insulations as well as indoor air quality. It is important to understand and enhance the mechanical properties of this material, where a high degree of variation is reported in the literature owing to lack of research and standardization in this field. The present paper focuses first on the understanding of mechanical behaviour of adobe subjected to compressive stresses as well as flexure and then on enhancing the same with the help of steel wire mesh as reinforcement. A total of 22 samples were tested out of which, 12 cube samples were tested for compressive strength, whereas 10 beams samples were tested for modulus of rupture. Half of the samples in each category were control samples i.e. without wire mesh reinforcement, whereas the remaining half were reinforced with a single layer of wire mesh per sample. It has been found that the compressive strength of adobe increases by about 43% after adding a single layer of wire mesh reinforcement. The flexural response of adobe has also shown improvement with the addition of wire mesh reinforcement.

  10. Acceptability and usability of self-collected sampling for HPV testing among African-American women living in the Mississippi Delta.

    Science.gov (United States)

    Scarinci, Isabel C; Litton, Allison G; Garcés-Palacio, Isabel C; Partridge, Edward E; Castle, Philip E

    2013-01-01

    Human papillomavirus (HPV) DNA testing has been shown to be an effective approach to cervical cancer screening, and self-collection sampling for HPV testing could be a potential alternative to Pap test, provided that women who tested positive by any method get timely follow-up and care. This feasibility study examined acceptability and usability of self-collected sampling for HPV testing among African-American (AA) women in the Mississippi Delta to inform the development of interventions to promote cervical cancer screening in this population. The study consisted of two phases. Phase I consisted of eight focus groups (n = 87) with AA women to explore knowledge, attitudes, and beliefs about cervical cancer and HPV infection as well as acceptability of self-collected sampling for HPV testing. In phase II, we examined the usability of this technology through one discussion group (n = 9). The Health Belief Model guided data collection and analysis. Although participants perceived themselves as susceptible to cervical cancer and acknowledged its severity, there was a lack of knowledge of the link between HPV and cervical cancer, and they expressed a number of misconceptions. The most frequent barriers to screening included embarrassment, discomfort, and fear of the results. Women in both phases were receptive to self-collected sampling for HPV testing. All participants in the usability phase expressed that self-collection was easy and they did not experience any difficulties. Self-collection for HPV testing is an acceptable and feasible method among AA women in the Mississippi Delta to complement current cytology cervical cancer screening programs. Copyright © 2013 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  11. Inert medium (helium) irradiation testing of pressure tube samples

    International Nuclear Information System (INIS)

    Ancuta, M.; Radu, V.; Stefan, V.; Preda, M.

    2001-01-01

    Irradiation tests currently performed in C-5 capsule aim at obtaining data and information concerning behavior to irradiation of pressure tubes of CANDU type fuel channel, to evidence the factors limiting operation life span. A calculation code for analysis and prediction of pressure tube behavior should be based upon periodical inspection results, post irradiation examination of the removed from reactor pressure tubes as well as on the experimental results obtained with materials subjected to irradiation conditions identical with the operational ones. Mechanical behavior analysis should focus both complex thermal-mechanical type stresses and mechanical properties alteration under irradiation. The experimental results should be applied: - to evaluate the irradiation effects upon mechanical properties of Zr-2.5% Nb exposed to fluences up to 10 21 n·cm -2 ; - to gather data concerning the real stress / real deformation characteristic from which characteristic quantities can be deduced as, for instance, elasticity modulus, plasticity modulus, exponent of stress term in the Tsu-Berteles relation, to be used within the CANTUP simulation code describing pressure tube behavior, currently developed at INR Pitesti; - to develop prediction methods of pressure tube behavior and merging with in-service inspection procedure in order to forecast the life span and the proper timing for replacement before major failures occur. The samples irradiated in C-5 capsule were extracted from the ends of Zr-2.5% Nb pressure tubes resulting from Cernavoda NPP Unit 1. The samples for tensile tests were extracted on longitudinal and transversal directions of the pressure tube. The tests were carried out under following conditions: - test environment temperature, 260 - 280 deg.C; - testing medium, helium at 1 - 6 b pressure; - neutron flux (E n > 1 MeV), 1 - 2 · 10 13 ncm -2 s -1 ; - neutron fluence (E n > 1 MeV), 4 · 10 20 ncm -2 . The following characteristics were obtained from tensile

  12. Dipstick test for rapid diagnosis of Shigella dysenteriae 1 in bacterial cultures and its potential use on stool samples.

    Directory of Open Access Journals (Sweden)

    Neelam Taneja

    Full Text Available BACKGROUND: We describe a test for rapid detection of S. dysenteriae 1 in bacterial cultures and in stools, at the bedside of patients. METHODOLOGY/PRINCIPAL FINDINGS: The test is based on the detection of S. dysenteriae 1 lipopolysaccharide (LPS using serotype 1-specific monoclonal antibodies coupled to gold particles and displayed on a one-step immunochromatographic dipstick. A concentration as low as 15 ng/ml of LPS was detected in distilled water and in reconstituted stools in 10 minutes. In distilled water and in reconstituted stools, an unequivocal positive reaction was obtained with 1.6×10⁶ CFU/ml and 4.9×10⁶ CFU/ml of S. dysenteriae 1, respectively. Optimal conditions to read the test have been determined to limit the risk of ambiguous results due to appearance of a faint yellow test band in some negative samples. The specificity was 100% when tested with a battery of Shigella and unrelated strains in culture. When tested on 328 clinical samples in India, Vietnam, Senegal and France by laboratory technicians and in Democratic Republic of Congo by a field technician, the specificity (312/316 was 98.7% (95% CI:96.6-99.6% and the sensitivity (11/12 was 91.7% (95% CI:59.8-99.6%. Stool cultures and the immunochromatographic test showed concordant results in 98.4 % of cases (323/328 in comparative studies. Positive and negative predictive values were 73.3% (95% CI:44.8-91.1% and 99.7% (95% CI:98-100%. CONCLUSION: The initial findings presented here for a simple dipstick-based test to diagnose S. dysenteriae 1 demonstrates its promising potential to become a powerful tool for case management and epidemiological surveys.

  13. Estimation of sample size and testing power (Part 4).

    Science.gov (United States)

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2012-01-01

    Sample size estimation is necessary for any experimental or survey research. An appropriate estimation of sample size based on known information and statistical knowledge is of great significance. This article introduces methods of sample size estimation of difference test for data with the design of one factor with two levels, including sample size estimation formulas and realization based on the formulas and the POWER procedure of SAS software for quantitative data and qualitative data with the design of one factor with two levels. In addition, this article presents examples for analysis, which will play a leading role for researchers to implement the repetition principle during the research design phase.

  14. THE INVESTIGATION OF BRUCELLA ANTIBODY WITH MILK RING TEST AND AGGLUTINATION TEST IN MILK COLLECTED FROM SAMSUN REGION

    Directory of Open Access Journals (Sweden)

    Goknur TERZI

    2006-06-01

    Full Text Available In this study Brucella antibodies were investigated with agglutination test (Whey-AT and Milk Ring Test (MRT in a total of 100 milk samples as 50 of cow milk and 50 of goat milk collected from center and villages of Samsun. According to MRT Brucella antibodies was positive at 10 samples (20 % of cow milk and 6 samples (12 % of goat milk. In cow milk, 4 (8 % positive, 3 (6 % suspicious and 43 (86 % negative samples; in goat milk 3 (6 % positive, 2 (4 % suspicious and 45 (90 % negative samples were determined according to antibodies titre of serum agglutination test (Whey-AT. [TAF Prev Med Bull 2006; 5(3.000: 196-203

  15. Microbiological analyses of samples from the H-Area injection well test site

    International Nuclear Information System (INIS)

    Wilde, E.W.; Franck, M.M.

    1997-01-01

    Microbial populations in well water from monitoring wells at the test site were one to three orders of magnitude higher than well water from the Cretaceous aquifer (used as dilution water for the tests) or from a control well adjacent to the test site facility. Coupons samples placed in monitoring and control wells demonstrated progressive adhesion by microbes to materials used in well construction. Samples of material scraped from test well components during abandonment of the test site project revealed the presence of a variety of attached microbes including iron bacteria. Although the injection wells at the actual remediation facility for the F- and H-Area seepage basins remediation project are expected to be subjected to somewhat different conditions (e.g. considerably lower iron concentrations) than was the case at the test site, the potential for microbiologically mediated clogging and fouling within the process should be considered. A sampling program that includes microbiological testing is highly recommended

  16. Primary care visit use after positive fecal immunochemical test for colorectal cancer screening.

    Science.gov (United States)

    Hillyer, Grace Clarke; Jensen, Christopher D; Zhao, Wei K; Neugut, Alfred I; Lebwohl, Benjamin; Tiro, Jasmin A; Kushi, Lawrence H; Corley, Douglas A

    2017-10-01

    For some patients, positive cancer screening test results can be a stressful experience that can affect future screening compliance and increase the use of health care services unrelated to medically indicated follow-up. Among 483,216 individuals aged 50 to 75 years who completed a fecal immunochemical test to screen for colorectal cancer at a large integrated health care setting between 2007 and 2011, the authors evaluated whether a positive test was associated with a net change in outpatient primary care visit use within the year after screening. Multivariable regression models were used to evaluate the relationship between test result group and net changes in primary care visits after fecal immunochemical testing. In the year after the fecal immunochemical test, use increased by 0.60 clinic visits for patients with true-positive results. The absolute change in visits was largest (3.00) among individuals with positive test results who were diagnosed with colorectal cancer, but significant small increases also were found for patients treated with polypectomy and who had no neoplasia (0.36) and those with a normal examination and no polypectomy performed (0.17). Groups of patients who demonstrated an increase in net visit use compared with the true-negative group included patients with true-positive results (odds ratio [OR], 1.60; 95% confidence interval [95% CI], 1.54-1.66), and positive groups with a colorectal cancer diagnosis (OR, 7.19; 95% CI, 6.12-8.44), polypectomy/no neoplasia (OR, 1.37; 95% CI, 1.27-1.48), and normal examination/no polypectomy (OR, 1.24; 95% CI, 1.18-1.30). Given the large size of outreach programs, these small changes can cumulatively generate thousands of excess visits and have a substantial impact on total health care use. Therefore, these changes should be included in colorectal cancer screening cost models and their causes investigated further. Cancer 2017;123:3744-3753. © 2017 American Cancer Society. © 2017 American Cancer Society.

  17. Country-wide surveillance of molecular markers of antimalarial drug resistance in Senegal by use of positive Malaria Rapid Diagnostic Tests

    DEFF Research Database (Denmark)

    Ndiaye, Magatte; Sow, Doudou; Nag, Sidsel

    2017-01-01

    of drug resistance. Therefore, surveillance of drug resistance in the malaria parasites is essential. The objective of this pilot study was to test the feasibility of routinely sampled malaria rapid diagnostic tests (RDTs) at a national scale to assess the temporal changes in the molecular profiles...... of antimalarial drug resistance markers of Plasmodium falciparum parasites. Overall, 9,549 positive malaria RDTs were collected from 14 health facilities across the country. A limited random set of RDTs were analyzed regarding Pfcrt gene polymorphisms at codon 72-76. Overall, a high but varied prevalence (> 50...

  18. Operability test report for core sample truck number one flammable gas modifications

    International Nuclear Information System (INIS)

    Akers, J.C.

    1997-01-01

    This report primarily consists of the original test procedure used for the Operability Testing of the flammable gas modifications to Core Sample Truck No. One. Included are exceptions, resolutions, comments, and test results. This report consists of the original, completed, test procedure used for the Operability Testing of the flammable gas modifications to the Push Mode Core Sample Truck No. 1. Prior to the Acceptance/Operability test the truck No. 1 operations procedure (TO-080-503) was revised to be more consistent with the other core sample truck procedures and to include operational steps/instructions for the SR weather cover pressurization system. A draft copy of the operations procedure was used to perform the Operability Test Procedure (OTP). A Document Acceptance Review Form is included with this report (last page) indicating the draft status of the operations procedure during the OTP. During the OTP 11 test exceptions were encountered. Of these exceptions four were determined to affect Acceptance Criteria as listed in the OTP, Section 4.7 ACCEPTANCE CRITERIA

  19. Page sample size in web accessibility testing: how many pages is enough?

    NARCIS (Netherlands)

    Velleman, Eric Martin; van der Geest, Thea

    2013-01-01

    Various countries and organizations use a different sampling approach and sample size of web pages in accessibility conformance tests. We are conducting a systematic analysis to determine how many pages is enough for testing whether a website is compliant with standard accessibility guidelines. This

  20. Different goodness of fit tests for Rayleigh distribution in ranked set sampling

    Directory of Open Access Journals (Sweden)

    Amer Al-Omari

    2016-03-01

    Full Text Available In this paper, different goodness of fit tests for the Rayleigh distribution are considered based on simple random sampling (SRS and ranked set sampling (RSS techniques. The performance of the suggested estimators is evaluated in terms of the power of the tests by using Monte Carlo simulation. It is found that the suggested RSS tests perform better than their counterparts  in SRS.

  1. A Third Moment Adjusted Test Statistic for Small Sample Factor Analysis.

    Science.gov (United States)

    Lin, Johnny; Bentler, Peter M

    2012-01-01

    Goodness of fit testing in factor analysis is based on the assumption that the test statistic is asymptotically chi-square; but this property may not hold in small samples even when the factors and errors are normally distributed in the population. Robust methods such as Browne's asymptotically distribution-free method and Satorra Bentler's mean scaling statistic were developed under the presumption of non-normality in the factors and errors. This paper finds new application to the case where factors and errors are normally distributed in the population but the skewness of the obtained test statistic is still high due to sampling error in the observed indicators. An extension of Satorra Bentler's statistic is proposed that not only scales the mean but also adjusts the degrees of freedom based on the skewness of the obtained test statistic in order to improve its robustness under small samples. A simple simulation study shows that this third moment adjusted statistic asymptotically performs on par with previously proposed methods, and at a very small sample size offers superior Type I error rates under a properly specified model. Data from Mardia, Kent and Bibby's study of students tested for their ability in five content areas that were either open or closed book were used to illustrate the real-world performance of this statistic.

  2. Research on test of product based on spatial sampling criteria and variable step sampling mechanism

    Science.gov (United States)

    Li, Ruihong; Han, Yueping

    2014-09-01

    This paper presents an effective approach for online testing the assembly structures inside products using multiple views technique and X-ray digital radiography system based on spatial sampling criteria and variable step sampling mechanism. Although there are some objects inside one product to be tested, there must be a maximal rotary step for an object within which the least structural size to be tested is predictable. In offline learning process, Rotating the object by the step and imaging it and so on until a complete cycle is completed, an image sequence is obtained that includes the full structural information for recognition. The maximal rotary step is restricted by the least structural size and the inherent resolution of the imaging system. During online inspection process, the program firstly finds the optimum solutions to all different target parts in the standard sequence, i.e., finds their exact angles in one cycle. Aiming at the issue of most sizes of other targets in product are larger than that of the least structure, the paper adopts variable step-size sampling mechanism to rotate the product specific angles with different steps according to different objects inside the product and match. Experimental results show that the variable step-size method can greatly save time compared with the traditional fixed-step inspection method while the recognition accuracy is guaranteed.

  3. A closer look at the effect of preliminary goodness-of-fit testing for normality for the one-sample t-test.

    Science.gov (United States)

    Rochon, Justine; Kieser, Meinhard

    2011-11-01

    Student's one-sample t-test is a commonly used method when inference about the population mean is made. As advocated in textbooks and articles, the assumption of normality is often checked by a preliminary goodness-of-fit (GOF) test. In a paper recently published by Schucany and Ng it was shown that, for the uniform distribution, screening of samples by a pretest for normality leads to a more conservative conditional Type I error rate than application of the one-sample t-test without preliminary GOF test. In contrast, for the exponential distribution, the conditional level is even more elevated than the Type I error rate of the t-test without pretest. We examine the reasons behind these characteristics. In a simulation study, samples drawn from the exponential, lognormal, uniform, Student's t-distribution with 2 degrees of freedom (t(2) ) and the standard normal distribution that had passed normality screening, as well as the ingredients of the test statistics calculated from these samples, are investigated. For non-normal distributions, we found that preliminary testing for normality may change the distribution of means and standard deviations of the selected samples as well as the correlation between them (if the underlying distribution is non-symmetric), thus leading to altered distributions of the resulting test statistics. It is shown that for skewed distributions the excess in Type I error rate may be even more pronounced when testing one-sided hypotheses. ©2010 The British Psychological Society.

  4. IgG4-positive cell infiltration in various cardiovascular disorders - results from histopathological analysis of surgical samples.

    Science.gov (United States)

    Hourai, Ryoto; Kasashima, Satomi; Sohmiya, Koichi; Yamauchi, Yohei; Ozawa, Hideki; Hirose, Yoshinobu; Ogino, Yasuhiro; Katsumata, Takahiro; Daimon, Masahiro; Fujita, Shu-Ichi; Hoshiga, Masaaki; Ishizaka, Nobukazu

    2017-02-03

    The diagnosis of Immunoglobulin G4 (IgG4)-related disease (IgG4-RD), in general, depends on serum IgG4 concentrations and histopathological findings; therefore, diagnosis of IgG4-RD in cardiovascular organs/tissues is often difficult owing to the risk of tissue sampling. Prevalence of IgG4-positive lymphoplasmacytic infiltration in 103 consecutive cardiovascular surgical samples from 98 patients with various cardiovascular diseases was analyzed immunohistochemically. The diagnoses of the enrolled patients included aortic aneurysm (abdominal, n = 8; thoracic, n = 9); aortic dissection (n = 20); aortic stenosis (n = 24), aortic regurgitation (n = 10), and mitral stenosis/regurgitation (n = 17). In total, 10 (9.7%) of the 103 specimens showed IgG4-positive cell infiltration with various intensities; five of these were aortic valve specimens from aortic stenosis, and IgG4-positive cell infiltration was present at >10 /HPF in three of them. In one aortic wall sample from an abdominal aortic aneurysm, various histopathological features of IgG4-RD, such as IgG4-positive cell infiltration, obliterating phlebitis, and storiform fibrosis, were observed. IgG4-positive cell infiltration was observed in 9.7% of the surgical cardiovascular specimens, mainly in the aortic valve from aortic stenosis and in the aortic wall from aortic aneurysm. Whether IgG4-positive cell infiltration has pathophysiological importance in the development or progression of cardiovascular diseases should be investigated in future studies.

  5. Predictors for benign paroxysmal positional vertigo with positive Dix–Hallpike test

    Directory of Open Access Journals (Sweden)

    Noda K

    2011-12-01

    Full Text Available Kazutaka Noda, Masatomi Ikusaka, Yoshiyuki Ohira, Toshihiko Takada, Tomoko TsukamotoDepartment of General Medicine, Chiba University Hospital, Chiba, JapanObjective: Patient medical history is important for making a diagnosis of causes of dizziness, but there have been no studies on the diagnostic value of individual items in the history. This study was performed to identify and validate useful questions for suspecting a diagnosis of benign paroxysmal positional vertigo (BPPV.Methods: Construction and validation of a disease prediction model was performed at the outpatient clinic in the Department of General Medicine of Chiba University Hospital. Patients with dizziness were enrolled (145 patients for construction of the disease prediction model and 61 patients for its validation. This study targeted BPPV of the posterior semicircular canals only with a positive Dix–Hallpike test (DHT + BPPV to avoid diagnostic ambiguity. Binomial logistic regression analysis was performed to identify the items that were useful for diagnosis or exclusion of DHT + BPPV.Results: Twelve patients from the derivation set and six patients from the validation set had DHT + BPPV. Binomial logistic regression analysis selected a "duration of dizziness ≤15 seconds" and "onset when turning over in bed" as independent predictors of DHT + BPPV with an odds ratio (95% confidence interval of 4.36 (1.18–16.19 and 10.17 (2.49–41.63, respectively. Affirmative answers to both questions yielded a likelihood ratio of 6.81 (5.11–9.10 for diagnosis of DHT + BPPV, while negative answers to both had a likelihood ratio of 0.19 (0.08–0.47.Conclusion: A "duration of dizziness ≤15 seconds" and "onset when turning over in bed" were the two most important questions among various historical features of BPPV.Keywords: benign paroxysmal positional vertigo, likelihood ratio, diagnosis, screening, prediction rules

  6. ASSESSMENT OF ANAEROBIC THRESHOLD IN FOOTBALL PLAYERS ON DIFFERENT POSITIONS, USING THE CONCONI TEST

    Directory of Open Access Journals (Sweden)

    Milan Cvetković

    2014-06-01

    Full Text Available Introduction: Requirements and needs of properly programmed training process, especially in the pre-season, look for a precise definition of the functional parameters of all the players. The level of anaerobic threshold, as well as research on the same, may be a good indicator of proper dosage of loading. The aim of the research is to determine the differences in running speed and heart rate at the level of anaerobic threshold in relation to the position of the player. Methods: Age of the respondents in this study included boys from 14 to 16 years of age (60 football players. The sample of respondents was divided according to playing position, as follows: center-backs (12 players, wing-backs (15 players, midfielders (14 players, forwarders (13 players and goalkeepers (6 goalkeepers. An estimation of maximum heart rate and anaerobic threshold was performed using the Conconi test – (Conconi et al. 1996. Prior to testing players had ten minutes to warm up and after a few minutes of rest the testing began. Players started with jogging test (10 km/h and after every 200 m running speed was increased by 0.5 km/h. Within certain sections the load is constant which is achieved by increasing speed after each 200 m, and then maintaining that speed until the end of the section. After processing the results within the particular software (“Polar Precision Performance SW” the values needed for this research were collected. Multivariate methods MANOVA and discriminant analysis will be applied in the paper. Regarding the univariate procedures, ANOVA t-test and Roy’s test shall be applied. The descriptive parameters, mean value, standard deviation (SD, minimum and maximum of all values, the coefficient of variation (CV of confidence intervals, skewness as the measures of asymmetry, kurtosis as the measure of flatness and the value of the Kolmogorov-Smirnov test, shall be presented. Results: By using the multivariate analysis of variance and based on the

  7. On the matched pairs sign test using bivariate ranked set sampling ...

    African Journals Online (AJOL)

    BVRSS) is introduced and investigated. We show that this test is asymptotically more efficient than its counterpart sign test based on a bivariate simple random sample (BVSRS). The asymptotic null distribution and the efficiency of the test are derived.

  8. A novel method for single sample multi-axial nanoindentation of hydrated heterogeneous tissues based on testing great white shark jaws.

    Science.gov (United States)

    Ferrara, Toni L; Boughton, Philip; Slavich, Eve; Wroe, Stephen

    2013-01-01

    Nanomechanical testing methods that are suitable for a range of hydrated tissues are crucial for understanding biological systems. Nanoindentation of tissues can provide valuable insights into biology, tissue engineering and biomimetic design. However, testing hydrated biological samples still remains a significant challenge. Shark jaw cartilage is an ideal substrate for developing a method to test hydrated tissues because it is a unique heterogeneous composite of both mineralized (hard) and non-mineralized (soft) layers and possesses a jaw geometry that is challenging to test mechanically. The aim of this study is to develop a novel method for obtaining multidirectional nanomechanical properties for both layers of jaw cartilage from a single sample, taken from the great white shark (Carcharodon carcharias). A method for obtaining multidirectional data from a single sample is necessary for examining tissue mechanics in this shark because it is a protected species and hence samples may be difficult to obtain. Results show that this method maintains hydration of samples that would otherwise rapidly dehydrate. Our study is the first analysis of nanomechanical properties of great white shark jaw cartilage. Variation in nanomechanical properties were detected in different orthogonal directions for both layers of jaw cartilage in this species. The data further suggest that the mineralized layer of shark jaw cartilage is less stiff than previously posited. Our method allows multidirectional nanomechanical properties to be obtained from a single, small, hydrated heterogeneous sample. Our technique is therefore suitable for use when specimens are rare, valuable or limited in quantity, such as samples obtained from endangered species or pathological tissues. We also outline a method for tip-to-optic calibration that facilitates nanoindentation of soft biological tissues. Our technique may help address the critical need for a nanomechanical testing method that is applicable

  9. A novel method for single sample multi-axial nanoindentation of hydrated heterogeneous tissues based on testing great white shark jaws.

    Directory of Open Access Journals (Sweden)

    Toni L Ferrara

    Full Text Available Nanomechanical testing methods that are suitable for a range of hydrated tissues are crucial for understanding biological systems. Nanoindentation of tissues can provide valuable insights into biology, tissue engineering and biomimetic design. However, testing hydrated biological samples still remains a significant challenge. Shark jaw cartilage is an ideal substrate for developing a method to test hydrated tissues because it is a unique heterogeneous composite of both mineralized (hard and non-mineralized (soft layers and possesses a jaw geometry that is challenging to test mechanically. The aim of this study is to develop a novel method for obtaining multidirectional nanomechanical properties for both layers of jaw cartilage from a single sample, taken from the great white shark (Carcharodon carcharias. A method for obtaining multidirectional data from a single sample is necessary for examining tissue mechanics in this shark because it is a protected species and hence samples may be difficult to obtain. Results show that this method maintains hydration of samples that would otherwise rapidly dehydrate. Our study is the first analysis of nanomechanical properties of great white shark jaw cartilage. Variation in nanomechanical properties were detected in different orthogonal directions for both layers of jaw cartilage in this species. The data further suggest that the mineralized layer of shark jaw cartilage is less stiff than previously posited. Our method allows multidirectional nanomechanical properties to be obtained from a single, small, hydrated heterogeneous sample. Our technique is therefore suitable for use when specimens are rare, valuable or limited in quantity, such as samples obtained from endangered species or pathological tissues. We also outline a method for tip-to-optic calibration that facilitates nanoindentation of soft biological tissues. Our technique may help address the critical need for a nanomechanical testing method

  10. The champagne toast position isolates the supraspinatus better than the Jobe test: an electromyographic study of shoulder physical examination tests.

    Science.gov (United States)

    Chalmers, Peter N; Cvetanovich, Gregory L; Kupfer, Noam; Wimmer, Markus A; Verma, Nikhil N; Cole, Brian J; Romeo, Anthony A; Nicholson, Gregory P

    2016-02-01

    While Jobe's test is widely used, it does not isolate supraspinatus activity. Our purpose was to examine the electromyographic (EMG) activity within the supraspinatus and deltoid with resisted abduction to determine the shoulder position that best isolates the activity of the supraspinatus. We performed EMG analysis of the supraspinatus, anterior head of the deltoid, and middle head of the deltoid in 10 normal volunteers. We measured EMG activity during resisted shoulder abduction in the scapular plane to both manual resistance and a standardized load in varying degrees of abduction and rotation. To determine which position best isolates supraspinatus activity, the ratio of supraspinatus to deltoid activity (S:D) was calculated for each position. Results were analyzed with a repeated-measures analysis of variance with Bonferroni correction. The posterior deltoid was excluded as it serves mostly to extend and externally rotate. Our study confirmed Jobe's findings of maximal supraspinatus activity at 90° of abduction. However, decreasing abduction significantly increased S:D for both resisted manual testing and testing against a standardized load (P = .002 and .001, respectively). The greatest S:D ratio (4.6 ± 3.4 for standardized load testing) was seen at the "champagne toast" position, i.e., 30° of abduction, mild external rotation, 30° of flexion, and 90° of elbow flexion. The smallest ratio (0.8 ± 0.6) was seen at Jobe's position. Testing of abduction strength in the champagne toast position, i.e., 30° of abduction, mild external rotation, and 30° of flexion, better isolates the activity of the supraspinatus from the deltoid than Jobe's "empty can" position. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Control rod position and temperature coefficients in HTTR power-rise tests. Interim report

    International Nuclear Information System (INIS)

    Fujimoto, Nozomu; Nojiri, Naoki; Takada, Eiji; Saito, Kenji; Kobayashi, Shoichi; Sawahata, Hiroaki; Kokusen, Sigeru

    2001-03-01

    Power-rise tests of the High Temperature Engineering Test Reactor (HTTR) have been carried out aiming to achieve 100% power. So far, 50% of power operation and many tests have been carried out. In the HTTR, temperature change in core is so large to achieve the outlet coolant temperature of 950degC. To improve the calculation accuracy of the HTTR reactor physics characteristics, control rod positions at criticality and temperature coefficients were measured at each step to achieve 50% power level. The calculations were carried out using Monte Carlo code and diffusion theory with temperature distributions in the core obtained by reciprocal calculation of thermo-hydraulic code and diffusion theory. Control rod positions and temperature coefficients were calculated by diffusion theory and Monte Carlo method. The test results were compared to calculation results. The control rod positions at criticality showed good agreement with calculation results by Monte Carlo method with error of 50 mm. The control position at criticality at 100% was predicted around 2900mm. Temperature coefficients showed good agreement with calculation results by diffusion theory. The improvement of calculation will be carried out comparing the measured results up to 100% power level. (author)

  12. 40 CFR 205.171-2 - Test exhaust system sample selection and preparation.

    Science.gov (United States)

    2010-07-01

    ... Systems § 205.171-2 Test exhaust system sample selection and preparation. (a)(1) Exhaust systems... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test exhaust system sample selection and preparation. 205.171-2 Section 205.171-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  13. Further examination of embedded performance validity indicators for the Conners' Continuous Performance Test and Brief Test of Attention in a large outpatient clinical sample.

    Science.gov (United States)

    Sharland, Michael J; Waring, Stephen C; Johnson, Brian P; Taran, Allise M; Rusin, Travis A; Pattock, Andrew M; Palcher, Jeanette A

    2018-01-01

    Assessing test performance validity is a standard clinical practice and although studies have examined the utility of cognitive/memory measures, few have examined attention measures as indicators of performance validity beyond the Reliable Digit Span. The current study further investigates the classification probability of embedded Performance Validity Tests (PVTs) within the Brief Test of Attention (BTA) and the Conners' Continuous Performance Test (CPT-II), in a large clinical sample. This was a retrospective study of 615 patients consecutively referred for comprehensive outpatient neuropsychological evaluation. Non-credible performance was defined two ways: failure on one or more PVTs and failure on two or more PVTs. Classification probability of the BTA and CPT-II into non-credible groups was assessed. Sensitivity, specificity, positive predictive value, and negative predictive value were derived to identify clinically relevant cut-off scores. When using failure on two or more PVTs as the indicator for non-credible responding compared to failure on one or more PVTs, highest classification probability, or area under the curve (AUC), was achieved by the BTA (AUC = .87 vs. .79). CPT-II Omission, Commission, and Total Errors exhibited higher classification probability as well. Overall, these findings corroborate previous findings, extending them to a large clinical sample. BTA and CPT-II are useful embedded performance validity indicators within a clinical battery but should not be used in isolation without other performance validity indicators.

  14. Operability test report for rotary mode core sampling system number 3

    International Nuclear Information System (INIS)

    Corbett, J.E.

    1996-01-01

    This report documents the successful completion of operability testing for the Rotary Mode Core Sampling (RMCS) system number-sign 3. The Report includes the test procedure (WHC-SD-WM-OTP-174), exception resolutions, data sheets, and a test report summary

  15. Characterization of electron microscopes with binary pseudo-random multilayer test samples

    Science.gov (United States)

    Yashchuk, Valeriy V.; Conley, Raymond; Anderson, Erik H.; Barber, Samuel K.; Bouet, Nathalie; McKinney, Wayne R.; Takacs, Peter Z.; Voronov, Dmitriy L.

    2011-09-01

    Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [1,2] and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi 2/Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

  16. Characterization of electron microscopes with binary pseudo-random multilayer test samples

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; Conley, Raymond; Anderson, Erik H.; Barber, Samuel K.; Bouet, Nathalie; McKinney, Wayne R.; Takacs, Peter Z.; Voronov, Dmitriy L.

    2011-01-01

    Verification of the reliability of metrology data from high quality X-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [5]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi 2 /Si multilayer coating with pseudo-randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize X-ray microscopes. Corresponding work with X-ray microscopes is in progress.

  17. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    Science.gov (United States)

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  18. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Science.gov (United States)

    2010-01-01

    ... samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic... for diagnostic testing. (b) The authorized laboratory must identify each egg as to the breeding flock...

  19. Detection test of wireless network signal strength and GPS positioning signal in underground pipeline

    Science.gov (United States)

    Li, Li; Zhang, Yunwei; Chen, Ling

    2018-03-01

    In order to solve the problem of selecting positioning technology for inspection robot in underground pipeline environment, the wireless network signal strength and GPS positioning signal testing are carried out in the actual underground pipeline environment. Firstly, the strength variation of the 3G wireless network signal and Wi-Fi wireless signal provided by China Telecom and China Unicom ground base stations are tested, and the attenuation law of these wireless signals along the pipeline is analyzed quantitatively and described. Then, the receiving data of the GPS satellite signal in the pipeline are tested, and the attenuation of GPS satellite signal under underground pipeline is analyzed. The testing results may be reference for other related research which need to consider positioning in pipeline.

  20. Participation behaviour following a false positive test in the Copenhagen mammography screening programme

    DEFF Research Database (Denmark)

    Andersen, Sune Bangsbøll; Vejborg, Ilse; von Euler-Chelpin, My

    2008-01-01

    women experiencing a negative screening test, regardless of whether the false positive statement was given following assessment or following surgery. The benign to malignant biopsy ratio, comparing the type B false positives to the true positives, was by the fifth round well below the desirable level...

  1. Skin irritability to sodium lauryl sulfate is associated with increased positive patch test reactions.

    Science.gov (United States)

    Schwitulla, J; Brasch, J; Löffler, H; Schnuch, A; Geier, J; Uter, W

    2014-07-01

    As previous observations have indicated an inter-relationship between irritant and allergic skin reactions we analysed data of synchronous allergen and sodium lauryl sulfate (SLS) patch tests in terms of a relationship between SLS responsiveness and allergic patch test reactions. To analyse differences in terms of allergen-specific and overall reaction profiles between patients with vs. those without an irritant reaction to SLS. Clinical data of 26 879 patients patch tested from 2008 to 2011 by members of the Information Network of Departments of Dermatology were analysed. After descriptive analyses, including the MOAHLFA index, the positivity ratio and the reaction index, a negative binomial hurdle model was adopted to investigate the correlation between SLS reactivity and positive patch test reactions. Men, patients aged ≥ 40 years and patients with an occupational dermatitis background were over-represented in the SLS-reactive group. Patients with an irritant reaction to SLS showed a higher proportion of weak positive reactions, as well as more questionable and irritant reactions to contact allergens than patients not reactive to SLS. The risk of an additional positive patch test reaction increased by 22% for SLS-reactive patients compared with those who were SLS negative. The marked association between SLS reactivity and the number of positive reactions in patch test patients may be due to nonspecific increased skin reactivity at the moment of patch testing only. However, increased SLS reactivity could also be due to longer-lasting enhanced skin irritability, which may have promoted (poly-)sensitization. Further studies, for example with longitudinal data on patients repeatedly patch tested with SLS and contact allergens, are necessary. © 2014 British Association of Dermatologists.

  2. The prevalence of skin-test-positive allergic rhinitis in Danish adults

    DEFF Research Database (Denmark)

    Linneberg, A; Jørgensen, T; Nielsen, N H

    2000-01-01

    BACKGROUND: It is disputed whether increases in self-reported respiratory allergy represent a true increase or merely increased recognition. We aimed to investigate whether the prevalence of skin-prick-test (SPT)-positive allergic rhinitis had increased in an adult general population in Copenhagen...... (participation rate 74.6%) and 482 (participation rate 53.4%) subjects were examined in 1990 and 1998, respectively. Diagnoses of SPT-positive allergic rhinitis were based on a history of nasal symptoms on exposure to allergens and SPT positivity to allergens. RESULTS: The prevalence of a diagnosis of SPT...

  3. A Shandon PapSpin liquid-based gynecological test: A split-sample and direct-to-vial test with histology follow-up study

    Directory of Open Access Journals (Sweden)

    Rimiene J

    2010-01-01

    positive predictive values for the conventional and PapSpin methods were not different in the split sample group: 88.0% vs 86.2% and 95.7% in the direct-to-vial group. Also, no differences were found for negative predictive value (82.1, 86.8% and 80.0% respectively. Conclusions: PapSpin showed good qualitative results in both study arms, even after the material splitting in the first study arm, and is a good alternative to the conventional Pap smear. Additionally, the PapSpin method offers several advantages such as the opportunity to prepare duplicate slides, option for HPV DNA testing and cell block preparations from residual material. Microscopic evaluation of thinner cell preparations is less time consuming than the conventional Pap smears.

  4. Design, building and test of one prototype and four final position sensor assemblies: Hall effect position sensors

    Science.gov (United States)

    1976-01-01

    This report covers the development of a three channel Hall effect position sensing system for the commutation of a three phase dc torquer motor. The effort consisted of the evaluation, modification and re-packaging of a commercial position sensor and the design of a target configuration unique to this application. The resulting design meets the contract requirements and, furthermore, the test results indicate not only the practicality and versatility of the design, but also that there may be higher limits of resolution and accuracy achievable.

  5. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  6. Analytic and clinical performance of cobas HPV testing in anal specimens from HIV-positive men who have sex with men.

    Science.gov (United States)

    Wentzensen, Nicolas; Follansbee, Stephen; Borgonovo, Sylvia; Tokugawa, Diane; Sahasrabuddhe, Vikrant V; Chen, Jie; Lorey, Thomas S; Gage, Julia C; Fetterman, Barbara; Boyle, Sean; Sadorra, Mark; Tang, Scott Dahai; Darragh, Teresa M; Castle, Philip E

    2014-08-01

    Anal human papillomavirus (HPV) infections are common, and the incidence of anal cancer is high in HIV-infected men who have sex with men (MSM). To evaluate the performance of HPV assays in anal samples, we compared the cobas HPV test (cobas) to the Roche Linear Array HPV genotyping assay (LA) and cytology in HIV-infected MSM. Cytology and cobas and LA HPV testing were conducted for 342 subjects. We calculated agreement between the HPV assays and the clinical performance of HPV testing and HPV genotyping alone and in combination with anal cytology. We observed high agreement between cobas and LA, with cobas more likely than LA to show positive results for HPV16, HPV18, and other carcinogenic types. Specimens testing positive in cobas but not in LA were more likely to be positive for other markers of HPV-related disease compared to those testing negative in both assays, suggesting that at least some of these were true positives for HPV. cobas and LA showed high sensitivities but low specificities for the detection of anal intraepithelial neoplasia grade 2/3 (AIN2/3) in this population (100% sensitivity and 26% specificity for cobas versus 98.4% sensitivity and 28.9% specificity for LA). A combination of anal cytology and HPV genotyping provided the highest accuracy for detecting anal precancer. A higher HPV load was associated with a higher risk of AIN2/3 with HPV16 (P(trend) < 0.001), HPV18 (P(trend) = 0.07), and other carcinogenic types (P(trend) < 0.001). We demonstrate that cobas can be used for HPV detection in anal cytology specimens. Additional tests are necessary to identify men at the highest risk of anal cancer among those infected with high-risk HPV. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  7. Systematic and non-systematic effects of the uncertainty of the sample position in gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Vidmar, T.; Korun, M.

    2004-01-01

    When cylindrical samples placed coaxially with the detector are measured on a gamma-ray spectrometer, the position of the sample very often deviates from an ideal one with the axes of the sample and the detector less than perfectly aligned. If a calibrated source is used prior to the measurement and is presumed to have been positioned correctly, one might conclude that the misalignment of the measured sample should result in an uncertainty of the reported nuclide activity, since the efficiencies of the sample and the calibrated source are effectively different due to the difference in placement. The efficiency of a displaced cylindrical sample, however, is always lower than the one of a sample that is perfectly aligned. The net effect of misalignment can therefore be not only an increase in the uncertainty of the activity, but also a systematic error in its evaluation. Since the Guide to the Expression of Uncertainty in Measurement requires that all such systematic effects be corrected for, we have developed a method to assess the change in the efficiency resulting from misalignment and to introduce the required correction. The calculation of this correction only requires knowledge of basic sample and detector data. The uncertainty of the reported activity can then also be assessed and is influenced by the uncertainty of the efficiency evaluated around its new, corrected value. An appropriate expression for this uncertainty has been derived

  8. Preliminary performance test of control rod position indicator for ballscrew type CEDM

    International Nuclear Information System (INIS)

    Yoo, J. Y.; Kim, J. H.; Hu, H.; Lee, J. S.; Kim, J. I.

    2003-01-01

    The reliability and accuracy of the information on control rod position are very important to the reactor safety and the design of the core protection system. A survey on the RSPT(Reed Switch Position Transmitter) type control rod position indication system and its actual implementation in the exiting nuclear power plants in Korea was performed first. The prototype of control rod position indicator having the high performance for the ballscrew type CEDM was developed on the basis of RSPT technology identified through the survey. The characteristics of control rod position indicator was defined and documented through design procedure and preliminary performance test

  9. Psychometric Quality of the Dutch Version of the Children's Eating Attitude Test in a Community Sample and a Sample of Overweight Youngsters

    Directory of Open Access Journals (Sweden)

    Lotte Theuwis

    2010-12-01

    Full Text Available Introduction. Disturbed eating attitudes may be important precursors of pathological eating patterns and, therefore need to be researched adequately. The Children's Eating Attitude Test (ChEAT is indicated for detecting at-risk attitudes and concerns in youngsters. Method. The present study was designed to provide a preliminary psychometric evaluation of the Dutch version of the ChEAT, by examining reliability and validity in a sample of 166 youngsters. Results. Generally the ChEAT seems to be a reliable instrument. Concurrent validity was demonstrated by positive correlations with measures assessing pathological eating behaviour and with related psychological problems. The discriminant validity was good. Based on ChEAT scores we can distinguish overweight youngsters from the community sample and “dieters” from “non dieters”. Divergent validity and factor structure show still shortcomings. Discussion. The Dutch version of the ChEAT seems to be a promising screening- and research instrument. Future prospective research could focus on a cut-off score for identifying at-risk youngsters.

  10. Sample test cases using the environmental computer code NECTAR

    International Nuclear Information System (INIS)

    Ponting, A.C.

    1984-06-01

    This note demonstrates a few of the many different ways in which the environmental computer code NECTAR may be used. Four sample test cases are presented and described to show how NECTAR input data are structured. Edited output is also presented to illustrate the format of the results. Two test cases demonstrate how NECTAR may be used to study radio-isotopes not explicitly included in the code. (U.K.)

  11. Coaxial test fixture

    Science.gov (United States)

    Praeg, Walter F.

    1986-01-01

    An assembly is provided for testing one or more contact material samples in a vacuum environment. The samples are positioned as an inner conductive cylinder assembly which is mounted for reciprocal vertical motion as well as deflection from a vertical axis. An outer conductive cylinder is coaxially positioned around the inner cylinder and test specimen to provide a vacuum enclosure therefor. A power source needed to drive test currents through the test specimens is connected to the bottom of each conductive cylinder, through two specially formed conductive plates. The plates are similar in form, having a plurality of equal resistance current paths connecting the power source to a central connecting ring. The connecting rings are secured to the bottom of the inner conductive assembly and the outer cylinder, respectively. A hydraulic actuator is also connected to the bottom of the inner conductor assembly to adjust the pressure applied to the test specimens during testing. The test assembly controls magnetic forces such that the current distribution through the test samples is symmetrical and that contact pressure is not reduced or otherwise disturbed.

  12. The effect of sequential dual-gas testing on laser-induced breakdown spectroscopy-based discrimination: Application to brass samples and bacterial strains

    International Nuclear Information System (INIS)

    Rehse, Steven J.; Mohaidat, Qassem I.

    2009-01-01

    Four Cu-Zn brass alloys with different stoichiometries and compositions have been analyzed by laser-induced breakdown spectroscopy (LIBS) using nanosecond laser pulses. The intensities of 15 emission lines of copper, zinc, lead, carbon, and aluminum (as well as the environmental contaminants sodium and calcium) were normalized and analyzed with a discriminant function analysis (DFA) to rapidly categorize the samples by alloy. The alloys were tested sequentially in two different noble gases (argon and helium) to enhance discrimination between them. When emission intensities from samples tested sequentially in both gases were combined to form a single 30-spectral line 'fingerprint' of the alloy, an overall 100% correct identification was achieved. This was a modest improvement over using emission intensities acquired in argon gas alone. A similar study was performed to demonstrate an enhanced discrimination between two strains of Escherichia coli (a Gram-negative bacterium) and a Gram-positive bacterium. When emission intensities from bacteria sequentially ablated in two different gas environments were combined, the DFA achieved a 100% categorization accuracy. This result showed the benefit of sequentially testing highly similar samples in two different ambient gases to enhance discrimination between the samples.

  13. Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

    International Nuclear Information System (INIS)

    TEMPLETON, A.M.

    2000-01-01

    This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications

  14. Acceptance sampling for attributes via hypothesis testing and the hypergeometric distribution

    Science.gov (United States)

    Samohyl, Robert Wayne

    2017-10-01

    This paper questions some aspects of attribute acceptance sampling in light of the original concepts of hypothesis testing from Neyman and Pearson (NP). Attribute acceptance sampling in industry, as developed by Dodge and Romig (DR), generally follows the international standards of ISO 2859, and similarly the Brazilian standards NBR 5425 to NBR 5427 and the United States Standards ANSI/ASQC Z1.4. The paper evaluates and extends the area of acceptance sampling in two directions. First, by suggesting the use of the hypergeometric distribution to calculate the parameters of sampling plans avoiding the unnecessary use of approximations such as the binomial or Poisson distributions. We show that, under usual conditions, discrepancies can be large. The conclusion is that the hypergeometric distribution, ubiquitously available in commonly used software, is more appropriate than other distributions for acceptance sampling. Second, and more importantly, we elaborate the theory of acceptance sampling in terms of hypothesis testing rigorously following the original concepts of NP. By offering a common theoretical structure, hypothesis testing from NP can produce a better understanding of applications even beyond the usual areas of industry and commerce such as public health and political polling. With the new procedures, both sample size and sample error can be reduced. What is unclear in traditional acceptance sampling is the necessity of linking the acceptable quality limit (AQL) exclusively to the producer and the lot quality percent defective (LTPD) exclusively to the consumer. In reality, the consumer should also be preoccupied with a value of AQL, as should the producer with LTPD. Furthermore, we can also question why type I error is always uniquely associated with the producer as producer risk, and likewise, the same question arises with consumer risk which is necessarily associated with type II error. The resolution of these questions is new to the literature. The

  15. Hepatitis C virus genotyping of organ donor samples to aid in transplantation of HCV-positive organs.

    Science.gov (United States)

    Gentile, Caren; Van Deerlin, Vivianna M; Goldberg, David S; Reese, Peter P; Hasz, Richard D; Abt, Peter; Blumberg, Emily; Farooqi, Midhat S

    2018-02-01

    Given the availability of new highly efficacious anti-HCV therapies, some clinicians have advocated for wider use of kidneys from hepatitis C virus-positive (HCV+) donors, including transplanting them into HCV-negative recipients. As treatment regimens for HCV are commonly guided by genotype, pretransplant HCV genotyping of tissue donors would be beneficial. To our knowledge, donor HCV genotyping has never been reported. We retrieved archived frozen plasma samples for 17 previous organ donors through a local organ procurement organization. We performed HCV genotyping using the eSensor HCVg Direct Test (GenMark Diagnostics) and also by Sanger sequencing, for confirmation (Retrogen). In addition, viral loads were measured using the COBAS AmpliPrep/TaqMan system (Roche Diagnostics). We found that most of the samples (n = 14) were HCV Genotype 1a with the remainder being Genotype 2b (n = 1) or Genotype 3 (n = 2). All genotyping results were concordant with Sanger sequencing. The average HCV viral load in the sample group was ~ 1.6 million IU/mL (range: ~16 000 IU/mL to 7 million IU/mL). We demonstrate that viral RNA from organ donor plasma can be successfully genotyped for HCV. This ability suggests that transplantation of HCV+ kidneys into HCV-negative recipients, followed by genotype-guided antiviral therapy, could be feasible. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Subtypes of depressive symptoms and inflammatory biomarkers: An exploratory study on a sample of HIV-positive patients.

    Science.gov (United States)

    Norcini Pala, A; Steca, P; Bagrodia, R; Helpman, L; Colangeli, V; Viale, P; Wainberg, M L

    2016-08-01

    Depressive symptoms cause major impairment and may accelerate HIV progression despite the use of antiretroviral medication. The somatic symptoms criteria for HIV infection and depression partially overlap, which can make differential diagnosis challenging. Because of chronic inflammation caused by HIV infection, HIV-positive patients may develop somatic and affective-cognitive symptoms of depression. Inflammation-related depression is primarily characterized with severe somatic symptoms such as fatigue and sleep disturbance. This study sought to explore the patterns of somatic and cognitive-affective depressive symptoms that characterize HIV-positive patients. Our specific aims were (1) to identify subtypes of depressive symptoms in a sample of HIV-positive patients; and (2) to test the subtypes' difference on inflammatory and HIV disease progression biomarkers. HIV-positive men and women (N=102) with and without depressive symptoms were randomly selected from an Italian HIV clinic. Depressive symptoms (PHQ-9), viral load (VL), CD4+, Il-6, TNF-α, and monocytes were assessed. The three subtypes formed using Latent Class Analysis (LCA) identified patients with (1) severe cognitive-affective and somatic depressive symptoms; (2) severe/moderate somatic symptoms; and (3) absent or low depressive symptoms. The subtype with severe/moderate somatic symptoms was characterized with elevated levels of Il-6 and monocytes. No difference on HIV progression biomarkers was found. The subtypes of depressive symptoms might help differentiating depressive symptoms from HIV- and inflammatory-related somatic symptoms. When present, cognitive-affective and/or somatic symptoms cause significant impairment to patients' lives and thus warrant further assessment and treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Newly developed liquid-based cytology. TACAS™: cytological appearance and HPV testing using liquid-based sample.

    Science.gov (United States)

    Kubushiro, Kaneyuki; Taoka, Hideki; Sakurai, Nobuyuki; Yamamoto, Yasuhiro; Kurasaki, Akiko; Asakawa, Yasuyuki; Iwahara, Minoru; Takahashi, Kei

    2011-09-01

    Cell profiles determined by the thin-layer advanced cytology assay system (TACAS™), a liquid-based cytology technique newly developed in Japan, were analyzed in this study. Hybrid capture 2 (HC-2) was also performed using the liquid-based samples prepared by TACAS to ascertain its ability to detect human papillomavirus (HPV). Cell collection samples from uterine cervix were obtained from 359 patients and examined cytologically. A HC-2 assay for HPV was carried out in the cell specimens. All specimens were found to show background factors such as leukocytes. After excluding the 5 unsatisfactory cases from the total 354 cases, 82 cases (23.2%) were positive and 272 cases (76.8%) were negative for HPV. Cell specimens from 30 HPV-positive cases and 166 HPV-negative cases were subjected to 4 weeks of preservation at room temperature. Then, when subsequently re-assayed, 28 cases (93.3%) in the former group were found to be HPV positive and 164 cases (98.8%) in the latter group were found to be HPV negative. These results supported the excellent reproducibility of TACAS for HPV testing. A reasonable inference from the foregoing analysis is that TACAS may be distinguished from other liquid-based cytological approaches, such as ThinPrep and SurePath, in that it can retain the cell backgrounds. Furthermore, this study raises the possibility that cell specimens prepared using TACAS could be preserved for at least 4 weeks prior to carrying out a HC-2 assay for HPV.

  18. Robustness to non-normality of various tests for the one-sample location problem

    Directory of Open Access Journals (Sweden)

    Michelle K. McDougall

    2004-01-01

    Full Text Available This paper studies the effect of the normal distribution assumption on the power and size of the sign test, Wilcoxon's signed rank test and the t-test when used in one-sample location problems. Power functions for these tests under various skewness and kurtosis conditions are produced for several sample sizes from simulated data using the g-and-k distribution of MacGillivray and Cannon [5].

  19. Associations between positive and negative affect and 12-month physical disorders in a national sample.

    Science.gov (United States)

    Weiser, Eric B

    2012-06-01

    Associations between positive and negative affect and a range of 12-month physical disorders were investigated in the Midlife Development in the United States Survey, a nationally representative sample of 3,032 adults ages 25-74. These associations were examined, controlling for relevant sociodemographic and psychiatric covariates. High positive affect was associated with decreased risk of physical disorders, whereas high negative affect was associated with increased risk. However, associations between positive affect and physical disorders were partially attenuated following adjustment for concurrent negative affect. Additionally, high affect balance was associated with decreased risk of physical disorders before and after adjustments. These findings underscore the relevance of affective disposition in health status, suggesting that both positive and negative affect may serve as viable health risk parameters.

  20. Harmonisation of microbial sampling and testing methods for distillate fuels

    Energy Technology Data Exchange (ETDEWEB)

    Hill, G.C.; Hill, E.C. [ECHA Microbiology Ltd., Cardiff (United Kingdom)

    1995-05-01

    Increased incidence of microbial infection in distillate fuels has led to a demand for organisations such as the Institute of Petroleum to propose standards for microbiological quality, based on numbers of viable microbial colony forming units. Variations in quality requirements, and in the spoilage significance of contaminating microbes plus a tendency for temporal and spatial changes in the distribution of microbes, makes such standards difficult to implement. The problem is compounded by a diversity in the procedures employed for sampling and testing for microbial contamination and in the interpretation of the data obtained. The following paper reviews these problems and describes the efforts of The Institute of Petroleum Microbiology Fuels Group to address these issues and in particular to bring about harmonisation of sampling and testing methods. The benefits and drawbacks of available test methods, both laboratory based and on-site, are discussed.

  1. Application and Comparative Evaluation of Fluorescent Antibody, Immunohistochemistry and Reverse Transcription Polymerase Chain Reaction Tests for the Detection of Rabies Virus Antigen or Nucleic Acid in Brain Samples of Animals Suspected of Rabies in India

    Directory of Open Access Journals (Sweden)

    K. Nithin Prabhu

    2018-02-01

    Full Text Available Accurate and early diagnosis of animal rabies is critical for undertaking public health measures. Whereas the direct fluorescent antibody (DFA technique is the recommended test, the more convenient, direct rapid immunochemistry test (dRIT, as well as the more sensitive, reverse transcription polymerase chain reaction (RT-PCR, have recently been employed for the laboratory diagnosis of rabies. We compared the three methods on brain samples from domestic (dog, cat, cattle, buffalo, horse, pig and goat and wild (leopard, wolf and jackal animals from various parts of India. Of the 257 samples tested, 167 were positive by all the three tests; in addition, 35 of the 36 decomposed samples were positive by RT-PCR. This is the first study in which such large number of animal samples have been subjected to the three tests simultaneously. The results confirm 100% corroboration between DFA and dRIT, buttress the applicability of dRIT in the simple and rapid diagnosis of rabies in animals, and reaffirm the suitability of RT-PCR for samples unfit for testing either by DFA or dRIT.

  2. Application and Comparative Evaluation of Fluorescent Antibody, Immunohistochemistry and Reverse Transcription Polymerase Chain Reaction Tests for the Detection of Rabies Virus Antigen or Nucleic Acid in Brain Samples of Animals Suspected of Rabies in India.

    Science.gov (United States)

    Prabhu, K Nithin; Isloor, Shrikrishna; Veeresh, B Hanchinal; Rathnamma, Doddamane; Sharada, R; Das, Lekshmi J; Satyanarayana, M L; Hegde, Nagendra R; Rahman, Sira Abdul

    2018-02-28

    Accurate and early diagnosis of animal rabies is critical for undertaking public health measures. Whereas the direct fluorescent antibody (DFA) technique is the recommended test, the more convenient, direct rapid immunochemistry test (dRIT), as well as the more sensitive, reverse transcription polymerase chain reaction (RT-PCR), have recently been employed for the laboratory diagnosis of rabies. We compared the three methods on brain samples from domestic (dog, cat, cattle, buffalo, horse, pig and goat) and wild (leopard, wolf and jackal) animals from various parts of India. Of the 257 samples tested, 167 were positive by all the three tests; in addition, 35 of the 36 decomposed samples were positive by RT-PCR. This is the first study in which such large number of animal samples have been subjected to the three tests simultaneously. The results confirm 100% corroboration between DFA and dRIT, buttress the applicability of dRIT in the simple and rapid diagnosis of rabies in animals, and reaffirm the suitability of RT-PCR for samples unfit for testing either by DFA or dRIT.

  3. Comparison of the Abbott RealTime High Risk HPV test and the Roche cobas 4800 HPV test using urine samples.

    Science.gov (United States)

    Lim, Myong Cheol; Lee, Do-Hoon; Hwang, Sang-Hyun; Hwang, Na Rae; Lee, Bomyee; Shin, Hye Young; Jun, Jae Kwan; Yoo, Chong Woo; Lee, Dong Ock; Seo, Sang-Soo; Park, Sang-Yoon; Joo, Jungnam

    2017-05-01

    Human papillomavirus (HPV) testing based on cervical samples is important for use in cervical cancer screening. However, cervical sampling is invasive. Therefore, non-invasive methods for detecting HPV, such as urine samples, are needed. For HPV detection in urine samples, two real-time PCR (RQ-PCR) tests, Roche cobas 4800 test (Roche_HPV; Roche Molecular Diagnostics) and Abbott RealTime High Risk HPV test (Abbott_HPV; Abbott Laboratories) were compared to standard cervical samples. The performance of Roche_HPV and Abbott_HPV for HPV detection was evaluated at the National Cancer Center using 100 paired cervical and urine samples. The tests were also compared using urine samples stored at various temperatures and for a range of durations. The overall agreement between the Roche_HPV and Abbott_HPV tests using urine samples for any hrHPV type was substantial (86.0% with a kappa value of 0.7173), and that for HPV 16/18 was nearly perfect (99.0% with a kappa value of 0.9668). The relative sensitivities (based on cervical samples) for HPV 16/18 detection using Roche_HPV and Abbott_HPV with urine samples were 79.2% (95% CI; 57.9-92.9%) and 81.8% (95% CI; 59.7-94.8%), respectively. When the cut-off C T value for Abbott_HPV was extended to 40 for urine samples, the relative sensitivity of Abbott_HPV increased to 91.7% from 81.8% for HPV16/18 detection and to 87.0% from 68.5% for other hrHPV detection. The specificity was not affected by the change in the C T threshold. Roche_HPV and Abbott_HPV showed high concordance. However, HPV DNA detection using urine samples was inferior to HPV DNA detection using cervical samples. Interestingly, when the cut-off C T value was set to 40, Abbott_HPV using urine samples showed high sensitivity and specificity, comparable to those obtained using cervical samples. Fully automated DNA extraction and detection systems, such as Roche_HPV and Abbott_HPV, could reduce the variability in HPV detection and accelerate the standardization of HPV

  4. Design, Development and Testing of a Semicircular Type Capacitive Angular Position Sensor

    Directory of Open Access Journals (Sweden)

    Nikhil GAURAV

    2011-06-01

    Full Text Available A low cost semicircular type capacitive angular position sensor has been designed, developed and tested. It is made of two semicircular parallel plates where one plate is fixed and another plate is connected with the rotor whose angular position is to be measured. When the angular position of the rotor changes with respect to the fixed plate, the overlapping area between the two plates of the capacitor is varied causing a change in capacitance value. Capacitance variation obtained due to the change in angular position is in the nano farad range. For signal conditioning, series R-L-C resonating circuit instead of conventional bridge circuit has been used to convert the sensor capacitance variation in to voltage. Experimental result shows that the capacitance for change in angular position 0º-180º increases linearly and for 180º-360º it decreases linearly. To get a linearly increasing response of same slope for the full scale of 0º-360º, a suitable linearising circuit has been designed, developed and tested. Sensor output along with the signal conditioning shows good linearity and repeatability.

  5. Characterization of electron microscopes with binary pseudo-random multilayer test samples

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; Conley, Raymond; Anderson, Erik H.; Barber, Samuel K.; Bouet, Nathalie; McKinney, Wayne R.; Takacs, Peter Z.; Voronov, Dmitriy L.

    2010-01-01

    We discuss the results of SEM and TEM measurements with the BPRML test samples fabricated from a BPRML (WSi2/Si with fundamental layer thickness of 3 nm) with a Dual Beam FIB (focused ion beam)/SEM technique. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-ray microscopes. Corresponding work with x-ray microscopes is in progress.

  6. The prevalence of toxoplasmosis in Imam Reza Hospital blood bank samples, Tehran, Iran.

    Science.gov (United States)

    Shaddel, M; Mirzaii Dizgah, I; Sharif, F

    2014-10-01

    The prevalence of toxoplasma gondii (T.g) infection in blood donors has been poorly studied. The aim of this study was to assess the prevalence of acute and chronic toxoplasmosis in blood products. A total of 223 blood products (101 fresh frozen plasma (FFP) and 122 packed cells (PC)) in Imam Reza hospital blood bank, Tehran, Iran were tested for specific T.g antibodies (IgG and IgM) by ELISA method. Positive IgG anti-T.g samples were further tested for IgM anti-T.g. A positive IgG test with the negative and positive IgM test was interpreted as a chronic and acute toxoplasmosis respectively. Of 223 samples 38.6% and 0.45% were positive for IgG anti-T.g and IgM anti-T.g levels respectively. Therefore, one and 85 samples were involved acute and chronic toxoplasmosis respectively. Twenty-six of fresh frozen plasma samples were positive for IgG anti-T.g and one of them was positive for IgM anti-T.g. Sixty packed cell samples were positive for IgG anti-T.g. Our study showed that there were chronic and acute toxoplasmosis in blood products and the prevalence of toxoplasmosis especially chronic form was high. Therefore screening of blood for T.g antibodies may be considered. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. The use of the milk ring test and rose bengal test in brucellosis control and eradication in Nigeria

    Directory of Open Access Journals (Sweden)

    S.I.B. Cadmus

    2008-05-01

    Full Text Available In this study, milk and blood samples collected simultaneously from 532 trade cows to be slaughtered at Bodija abattoir, Ibadan (southwestern, Nigeria were examined for antibodies to Brucella using the milk ring test (MRT and the rose bengal test (RBT. Overall, 18.61%of the milk samples were positive according to the MRT, while 9.77 % of the serum samples were positive according to the RBT. The difference was highly significant (Chi-square value 16.33; P<0.05; only 32 (6.02 % of the samples were positive for both tests. The Red Bororo breed of cattle and the White Fulani had the highest positive rates, namely 20.93 % and 11.69%for the MRT and RBT respectively.No conclusion can be drawn about sensitivity because we do not know the true status of the animals tested. It is, however, obvious that although the MRT and RBT are 1st-line screening tests for brucellosis in cows in some countries, their lack of specificity is of concern. Therefore, the requirement for other confirmatory tests that are more specific should be considered for control and eradication of the disease, especially in Nigeria.

  8. Accuracy and user-acceptability of HIV self-testing using an oral fluid-based HIV rapid test.

    Directory of Open Access Journals (Sweden)

    Oon Tek Ng

    Full Text Available BACKGROUND: The United States FDA approved an over-the-counter HIV self-test, to facilitate increased HIV testing and earlier linkage to care. We assessed the accuracy of self-testing by untrained participants compared to healthcare worker (HCW testing, participants' ability to interpret sample results and user-acceptability of self-tests in Singapore. METHODOLOGY/PRINCIPAL FINDINGS: A cross-sectional study, involving 200 known HIV-positive patients and 794 unknown HIV status at-risk participants was conducted. Participants (all without prior self-test experience performed self-testing guided solely by visual instructions, followed by HCW testing, both using the OraQuick ADVANCE Rapid HIV 1/2 Antibody Test, with both results interpreted by the HCW. To assess ability to interpret results, participants were provided 3 sample results (positive, negative, and invalid to interpret. Of 192 participants who tested positive on HCW testing, self-testing was positive in 186 (96.9%, negative in 5 (2.6%, and invalid in 1 (0.5%. Of 794 participants who tested negative on HCW testing, self-testing was negative in 791 (99.6%, positive in 1 (0.1%, and invalid in 2 (0.3%. Excluding invalid tests, self-testing had sensitivity of 97.4% (95% CI 95.1% to 99.7% and specificity of 99.9% (95% CI: 99.6% to 100%. When interpreting results, 96%, 93.1% and 95.2% correctly read the positive, negative and invalid respectively. There were no significant demographic predictors for false negative self-testing or wrongly interpreting positive or invalid sample results as negative. Eighty-seven percent would purchase the kit over-the-counter; 89% preferred to take HIV tests in private. 72.5% and 74.9% felt the need for pre- and post-test counseling respectively. Only 28% would pay at least USD15 for the test. CONCLUSIONS/SIGNIFICANCE: Self-testing was associated with high specificity, and a small but significant number of false negatives. Incorrectly identifying model results as

  9. BACTERIOLOGICAL STUDY OF COAGULASE-POSITIVE AND COAGULASE-NEGATIVE STAPHYLOCOCCI IN RELATION TO METHICILLIN SENSITIVITY TESTING

    Directory of Open Access Journals (Sweden)

    Padmanabham Yalangi

    2016-10-01

    Full Text Available BACKGROUND Staphylococcus aureus has long been recognised as an important pathogen in human disease. Staphylococci infection occurs regularly in hospitalised patients and has serious consequences despite antibiotic therapy. Shortly after introduction of methicillin after clinical use Methicillin-Resistant Staphylococcus Aureus (MRSA were identified in many countries and become one of the most common causes of nosocomial infections. The aim of the study is to know the methicillin sensitivity of both coagulase-negative and coagulase-positive staphylococci isolated from various samples. MATERIALS AND METHODS 100 strains of staphylococci both coagulase positive and coagulase negative were isolated in the Department of Microbiology from various clinical samples. They were confirmed by morphology, staining methods and by using standard bacteriological procedures and biochemical reactions. Antibiotic susceptibility testing was performed by Kirby Bauer disc diffusion test. RESULTS Predominant species from pus were S. epidermidis (42.42% and from sputum S. haemolyticus (31.81% from blood S. haemolyticus (53.33%. 53% of strains produced beta-lactamase. Majority 47.22% by S. epidermidis from pus followed by S. haemolyticus 23.33% from pus. Beta-lactamase production was least from throat swab (5.55%. Out of 32 coagulase-positive staphylococci tested to methicillin 15 (46.87% were found to be sensitive, 17 (53.13% were found to be resistant. Out of 68 coagulase-negative staphylococci tested, 13 (19.11% were found to sensitive and 55 (80.88% were found to be resistant. 72% of strains were sensitive to novobiocin and 28% resistant to novobiocin. 43% showed drug resistance to 2 drugs. 14% to 3 drugs and 5 drugs. 6% of staphylococci sensitive to all the 10 drugs. CONCLUSION MRSA is a type of bacteria that is resistant to a number of widely used antibiotics. This means MRSA infections can be more difficult to treat than other bacterial infections. In recent years

  10. Hydroxychloroquine-induced acute generalized exanthematous pustulosis with positive patch-testing.

    Science.gov (United States)

    Charfi, Ons; Kastalli, Sarrah; Sahnoun, Rym; Lakhoua, Ghozlane

    2015-01-01

    Acute generalized exanthematous pustulosis (AGEP) is a severe cutaneous adverse reaction, mostly induced by drugs. Hydroxychloroquine have been rarely reported in literature as a causative drug of this reaction. We report a case of AGEP induced by hydroxychloroquine with systemic involvement and confirmed by positive patch testing.

  11. Negativity bias and task motivation: testing the effectiveness of positively versus negatively framed incentives.

    Science.gov (United States)

    Goldsmith, Kelly; Dhar, Ravi

    2013-12-01

    People are frequently challenged by goals that demand effort and persistence. As a consequence, philosophers, psychologists, economists, and others have studied the factors that enhance task motivation. Using a sample of undergraduate students and a sample of working adults, we demonstrate that the manner in which an incentive is framed has implications for individuals' task motivation. In both samples we find that individuals are less motivated when an incentive is framed as a means to accrue a gain (positive framing) as compared with when the same incentive is framed as a means to avoid a loss (negative framing). Further, we provide evidence for the role of the negativity bias in this effect, and highlight specific populations for whom positive framing may be least motivating. Interestingly, we find that people's intuitions about when they will be more motivated show the opposite pattern, with people predicting that positively framed incentives will be more motivating than negatively framed incentives. We identify a lay belief in the positive correlation between enjoyment and task motivation as one possible factor contributing to the disparity between predicted and actual motivation as a result of the framing of the incentive. We conclude with a discussion of the managerial implications for these findings. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  12. Non-parametric adaptive importance sampling for the probability estimation of a launcher impact position

    International Nuclear Information System (INIS)

    Morio, Jerome

    2011-01-01

    Importance sampling (IS) is a useful simulation technique to estimate critical probability with a better accuracy than Monte Carlo methods. It consists in generating random weighted samples from an auxiliary distribution rather than the distribution of interest. The crucial part of this algorithm is the choice of an efficient auxiliary PDF that has to be able to simulate more rare random events. The optimisation of this auxiliary distribution is often in practice very difficult. In this article, we propose to approach the IS optimal auxiliary density with non-parametric adaptive importance sampling (NAIS). We apply this technique for the probability estimation of spatial launcher impact position since it has currently become a more and more important issue in the field of aeronautics.

  13. Effects of Blood Sample Collection Pre- and Post- Slaughter, Edta ...

    African Journals Online (AJOL)

    The samples were immediately subjected to Wet mount (WM), Haemotocrit centrifugation test (HCT) and Thin smear (TS) tests. The results revealed that, of the 100 samples examined, 19 (19%) were positive for the presence of Microfilaria spp while 6(6%) yielded Trypanosome spp. Of the 19 samples detected having ...

  14. Filtration and Leach Testing for REDOX Sludge and S-Saltcake Actual Waste Sample Composites

    Energy Technology Data Exchange (ETDEWEB)

    Shimskey, Rick W.; Billing, Justin M.; Buck, Edgar C.; Daniel, Richard C.; Draper, Kathryn E.; Edwards, Matthew K.; Geeting, John GH; Hallen, Richard T.; Jenson, Evan D.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Snow, Lanee A.; Swoboda, Robert G.

    2009-02-20

    A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.( ) The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Under test plan TP-RPP-WTP-467, eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. Under this test plan, a waste-testing program was implemented that included: • Homogenizing the archive samples by group as defined in the test plan • Characterizing the homogenized sample groups • Performing parametric leaching testing on each group for compounds of interest • Performing bench-top filtration/leaching tests in the hot cell for each group to simulate filtration and leaching activities if they occurred in the UFP2 vessel of the WTP Pretreatment Facility. This report focuses on filtration/leaching tests performed on two of the eight waste composite samples and follow-on parametric tests to support aluminum leaching results from those tests.

  15. 9 CFR 80.4 - Segregation of animals positive to an official Johne's disease test during interstate movement.

    Science.gov (United States)

    2010-01-01

    ... official Johne's disease test during interstate movement. 80.4 Section 80.4 Animals and Animal Products... animals positive to an official Johne's disease test during interstate movement. Animals that are positive... from the animals positive to an official Johne's disease test to the healthy animals in the vehicle. ...

  16. Big Data, Small Sample.

    Science.gov (United States)

    Gerlovina, Inna; van der Laan, Mark J; Hubbard, Alan

    2017-05-20

    Multiple comparisons and small sample size, common characteristics of many types of "Big Data" including those that are produced by genomic studies, present specific challenges that affect reliability of inference. Use of multiple testing procedures necessitates calculation of very small tail probabilities of a test statistic distribution. Results based on large deviation theory provide a formal condition that is necessary to guarantee error rate control given practical sample sizes, linking the number of tests and the sample size; this condition, however, is rarely satisfied. Using methods that are based on Edgeworth expansions (relying especially on the work of Peter Hall), we explore the impact of departures of sampling distributions from typical assumptions on actual error rates. Our investigation illustrates how far the actual error rates can be from the declared nominal levels, suggesting potentially wide-spread problems with error rate control, specifically excessive false positives. This is an important factor that contributes to "reproducibility crisis". We also review some other commonly used methods (such as permutation and methods based on finite sampling inequalities) in their application to multiple testing/small sample data. We point out that Edgeworth expansions, providing higher order approximations to the sampling distribution, offer a promising direction for data analysis that could improve reliability of studies relying on large numbers of comparisons with modest sample sizes.

  17. Post-Decontamination Vapor Sampling and Analytical Test Methods

    Science.gov (United States)

    2015-08-12

    is decontaminated that could pose an exposure hazard to unprotected personnel. The chemical contaminants may include chemical warfare agents (CWAs... decontamination process. Chemical contaminants can include chemical warfare agents (CWAs) or their simulants, nontraditional agents (NTAs), toxic industrial...a range of test articles from coupons, panels, and small fielded equipment items. 15. SUBJECT TERMS Vapor hazard; vapor sampling; chemical warfare

  18. 16 CFR 1203.15 - Positional stability test (roll-off resistance).

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Positional stability test (roll-off resistance). 1203.15 Section 1203.15 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT... over the helmet along the midsagittal plane and attaching the hook over the edge of the helmet as shown...

  19. Design of sample analysis device for iodine adsorption efficiency test in NPPs

    International Nuclear Information System (INIS)

    Ji Jinnan

    2015-01-01

    In nuclear power plants, iodine adsorption efficiency test is used to check the iodine adsorption efficiency of the iodine adsorber. The iodine adsorption efficiency can be calculated through the analysis of the test sample, and thus to determine if the performance of the adsorber meets the requirement on the equipment operation and emission. Considering the process of test and actual demand, in this paper, a special device for the analysis of this kind of test sample is designed. The application shows that the device is with convenient operation and high reliability and accurate calculation, and improves the experiment efficiency and reduces the experiment risk. (author)

  20. 9 CFR 80.3 - Movement of domestic animals that are positive to an official Johne's disease test.

    Science.gov (United States)

    2010-01-01

    ... positive to an official Johne's disease test. 80.3 Section 80.3 Animals and Animal Products ANIMAL AND... animals that are positive to an official Johne's disease test. (a) Movement of domestic animals for slaughter. Domestic animals that are positive to an official Johne's disease test may be moved interstate...

  1. [Necessity of repeated roll test in horizontal semicircular canalithasis positioned diagnosis].

    Science.gov (United States)

    Lu, H H; Zhao, Y; Chen, T S; Xu, K X; Wang, W; Liu, Q; Wen, C; Li, S S; Li, X J; Han, X; Lin, P

    2016-04-07

    To investigate the influence of repeated roll test in horizontal semicircular canalithasis(HSC-Can) positioned diagnosis, so as to investigate the cecessity of repeated roll test. The patients with a chief complaint of positional vertigo accepted two consecutive cycles roll test, the evoked nystagmus characteristics of each cycle recorded by video-nystagmuograph(VNG), whose direction, intensity, time and other parameters characteristics were analyzed in 51 HSC-Can. Horizontal nystagmus in the same direction with turning were induced in HSC-Can roll test. In 51 HSC-Can, roll test cycle 1 and cycle 2 induced nystagmus same strength side in 26 cases(51.0%), of which 19 cases with stronger nystagmus intensity in cycle 2, another 7 cases were weaker; the opposite strength side of the two loops induced nystagmus, and cycle 1 evoked nystagmus intensity were weaker than cycle 2, based on cycle 2 results determined HSC-Can affected side in 25 cases (49.0%). Lesion and normal side in cycle 1 induced nystagmus duration (x±s, the same below) were (13.4±11.5)s and (14.1±9.9)s, respectively intensity (18.1±22.4)°/s and (13.0±12.0)°/s; as in cycle 2 induced nystagmus duration was (20.7±10.2)s and (18.0±12.0)s, strength respectively(40.4±28.0)°/s and (15.6 ±11.2)°/s. Cycle 2 ipsilateral rotor position evoked nystagmus showed longer duration and stronger intensity than cycle 1. Between two cycle induced ipsilateral nystagmus duration, intensity differences were statistically significant (t values were -4.233 and -5.154, P=0.000). 51 HSC-Can patients, 44 patients selected repositioning maneuver, after 1-2 times of maneuver, 41 cases (93.2%) showed complete resolution of symptoms, all cases's symptoms were improved; other 7 patients selected medication only. The proposed suspicious HSC-Can patients should receive at least two cycles roll test, and mainly in the second cycle could determine the location of the responsible semicircular canals.

  2. Technical justifications for the tests and criteria in the waste form technical position appendix on cement stabilization

    International Nuclear Information System (INIS)

    Siskind, B.; Cowgill, M.G.

    1992-01-01

    As part of its technical assistance to the Nuclear Regulatory Commission (NRC), Brookhaven National Laboratory (BNL) developed a background document for the cement stabilization appendix, Appendix A, to Rev. 1 of the Technical Position on Waste Form (TP). Here we present an overview of this background document, which provides technical justification for the stability tests to be performed on cement-stabilized waste forms and for the criteria posed in each test, especially for those tests which have been changed from their counterparts in the May 1983 Rev. 0 TP. We address guidelines for procedures from Appendix A which are considered in less detail or not at all in the Rev. 0 of the TP, namely, qualification specimen preparation (mixing, curing, storage), statistical sampling and analysis, process control program specimen preparation and examination, and surveillance specimens. For each waste form qualification test, criterion or procedural guidelines, we consider the reason for its inclusion in Appendix A, the changes from Rev. 0 of the TP (if applicable), and a discussion of the justification or rationale for these changes

  3. Technical justifications for the tests and criteria in the waste form Technical position appendix on cement stabilization

    International Nuclear Information System (INIS)

    Siskind, B.; Cowgill, M.G.

    1992-01-01

    As part of its technical assistance to the Nuclear Regulatory Commission (NRC), Brookhaven National Laboratory (BNL) developed a background document for the cement stabilization appendix. Appendix A, to Rev. 1 of the Technical Position on Waste Form (TP). Here we present an overview of this background document, which provides technical justification for the stability tests to be performed on cement-stabilized waste forms and for the criteria posed in each test) especially for those tests which have been changed from their counterparts in the May 1983 Rev. 0 TP. We address guidelines for procedures from Appendix A which are considered in less detail or not at all in the Rev. 0 of the TP, namely, qualification specimen preparation (mixing, curing, storage), statistical sampling and analysis, process control program specimen preparation and examination, and surveillance specimens. For each waste form qualification test, criterion or procedural guideline, we consider the reason for its inclusion in Appendix A, the changes from Rev. 0 of the TP (if applicable), and a discussion of the justification or rationale for these changes. (author)

  4. Respondent-Driven SamplingTesting Assumptions: Sampling with Replacement

    Directory of Open Access Journals (Sweden)

    Barash Vladimir D.

    2016-03-01

    Full Text Available Classical Respondent-Driven Sampling (RDS estimators are based on a Markov Process model in which sampling occurs with replacement. Given that respondents generally cannot be interviewed more than once, this assumption is counterfactual. We join recent work by Gile and Handcock in exploring the implications of the sampling-with-replacement assumption for bias of RDS estimators. We differ from previous studies in examining a wider range of sampling fractions and in using not only simulations but also formal proofs. One key finding is that RDS estimates are surprisingly stable even in the presence of substantial sampling fractions. Our analyses show that the sampling-with-replacement assumption is a minor contributor to bias for sampling fractions under 40%, and bias is negligible for the 20% or smaller sampling fractions typical of field applications of RDS.

  5. tscvh R Package: Computational of the two samples test on microarray-sequencing data

    Science.gov (United States)

    Fajriyah, Rohmatul; Rosadi, Dedi

    2017-12-01

    We present a new R package, a tscvh (two samples cross-variance homogeneity), as we called it. This package is a software of the cross-variance statistical test which has been proposed and introduced by Fajriyah ([3] and [4]), based on the cross-variance concept. The test can be used as an alternative test for the significance difference between two means when sample size is small, the situation which is usually appeared in the bioinformatics research. Based on its statistical distribution, the p-value can be also provided. The package is built under a homogeneity of variance between samples.

  6. Antibiotic-induced immediate type hypersensitivity is a risk factor for positive allergy skin tests for neuromuscular blocking agents.

    Science.gov (United States)

    Hagau, Natalia; Gherman, Nadia; Cocis, Mihaela; Petrisor, Cristina

    2016-01-01

    Skin tests for neuromuscular blocking agents (NMBAs) are not currently recommended for the general population undergoing general anaesthesia. In a previous study we have reported a high incidence of positive allergy tests for NMBAs in patients with a positive history of non-anaesthetic drug allergy, a larger prospective study being needed to confirm those preliminary results. The objective of this study was to compare the skin tests results for patients with a positive history of antibiotic-induced immediate type hypersensitivity reactions to those of controls without drug allergies. Ninety eight patients with previous antibiotic hypersensitivity and 72 controls were prospectively included. Skin tests were performed for atracurium, pancuronium, rocuronium, and suxamethonium. We found 65 positive skin tests from the 392 tests performed in patients with a positive history of antibiotic hypersensitivity (1 6.58%) and 23 positive skin tests from the 288 performed in controls (7.98%), the two incidences showing significant statistical difference (p = 0.0011). The relative risk for having a positive skin test for NMBAs for patients versus controls was 1.77 (1.15-2.76). For atracurium, skin tests were more often positive in patients with a positive history of antibiotic hypersensitivity versus controls (p = 0.02). For pancuronium, rocuronium and suxamethonium the statistical difference was not attained (p-values 0.08 for pancuronium, 0.23 for rocuronium, and 0.26 for suxamethonium). Patients with a positive history of antibiotic hypersensitivity seem to have a higher incidence of positive skin tests for NMBAs. They might represent a group at higher risk for developing intraoperative anaphylaxis compared to the general population. Copyright © 2015 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  7. The outcome of dimethylglyoxime testing in a sample of cell phones in Denmark

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Johansen, Jeanne D; Zachariae, Claus

    2008-01-01

    BACKGROUND: Nickel dermatitis may be caused by frequent and prolonged use of cell phones. Because little is known about the frequency of nickel release from cell phones, it is difficult to estimate the risk of nickel sensitization and dermatitis among their users. OBJECTIVE: Inspired by a recent...... case of nickel dermatitis from prolonged cell phone use, the frequency of dimethylglyoxime (DMG)-positive cell phones on the Danish market was investigated. METHODS: Five major cell phone companies were contacted. Two were visited, and the DMG test was performed on a sample of their products. RESULTS...... phones from the Danish market. Prolonged use of cell phones may in some cases fulfil the criteria for items included in the European Union Nickel Directive. We believe that this new cause of nickel dermatitis should be carefully followed and that regulatory steps may be necessary....

  8. The outcome of dimethylglyoxime testing in a sample of cell phones in Denmark

    DEFF Research Database (Denmark)

    Thyssen, J.P.; Johansen, J.D.; Zachariae, C.

    2008-01-01

    Background: Nickel dermatitis may be caused by frequent and prolonged use of cell phones. Because little is known about the frequency of nickel release from cell phones, it is difficult to estimate the risk of nickel sensitization and dermatitis among their users. Objective: Inspired by a recent...... case of nickel dermatitis from prolonged cell phone use, the frequency of dimethylglyoxime (DMG)-positive cell phones on the Danish market was investigated. Methods: Five major cell phone companies were contacted. Two were visited, and the DMG test was performed on a sample of their products. Results...... phones from the Danish market. Prolonged use of cell phones may in some cases fulfil the criteria for items included in the European Union Nickel Directive. We believe that this new cause of nickel dermatitis should be carefully followed and that regulatory steps may be necessary Udgivelsesdato: 2008...

  9. Characterization of a low-level radioactive waste grout: Sampling and test results

    International Nuclear Information System (INIS)

    Martin, P.F.C.; Lokken, R.O.

    1992-12-01

    WHC manages and operates the grout treatment facility at Hanford as part of a DOE program to clean up wastes stored at federal nuclear production sites. PNL provides support to the grout disposal program through pilot-scale tests, performance assessments, and formulation verification activities. in 1988 and 1989, over one million gallons of a low-level radioactive liquid waste was processed through the facility to produce a grout waste that was then deposited in an underground vault. The liquid waste was phosphate/sulfate waste (PSW) generated in decontamination of the N Reactor. PNL sampled and tested the grout produced during the second half of the PSW campaign to support quality verification activities prior to grout vault closure. Samples of grout were obtained by inserting nested-tube samplers into the grout slurry in the vault. After the grout had cured, the inner tube of the sampler was removed and the grout samples extracted. Tests for compressive strength, sonic velocity, and leach testing were used to assess grout quality; results were compared to those from pilot-scale test grouts made with a simulated PSW. The grout produced during the second half of the PSW campaign exceeded compressive strength and leachability formulation criteria. The nested tube samplers were effective in collecting samples of grout although their use introduced greater variability into the compressive strength data

  10. [Tropheryma whipplei and Whipple disease: false positive PCR detections of Tropheryma whipplei in diagnostic samples are rare].

    Science.gov (United States)

    Le Scanff, J; Gaultier, J B; Durand, D Vital; Durieu, I; Celard, M; Benito, Y; Vandenesch, F; Rousset, H

    2008-11-01

    PCR can be used to detect T. whipplei (Tw) in samples from variable tissue types and body fluids. We report clinical, evolutive characteristics and final diagnosis in patients with positive Tw PCR assay. Retrospective study of Tw PCR realized since 10years in a microbiology laboratory. Twenty-five Tw PCR assays were positive among 200 realized. Diagnosis was not confirmed in six cases. One patient was missing for follow up. Eighteen patients presented with Whipple's disease. Among these 18 patients, 14 had a classic Whipple's disease, three patients presented an endocarditis and one patient isolated neurological manifestations. Ten patients presented fever, seven a weight loss and 12 joint involvement. Four patients presented cutaneous manifestations, only six had gastrointestinal symptoms. Neurological involvement was reported in five cases, pulmonary symptoms in four cases, cardiac involvement in six cases and ocular signs in two cases. Anemia was reported in four patients and elevated levels of acute-phase reactants in 14 cases. Positive predictive value of Tw PCR for Whipple's disease diagnosis was 75%. Thirteen patients had a good evolution with antibiotics. Three patients presented recurrence and two cases with cardiovascular involvement died. Whipple's disease is rare but often mentioned in internist experience. The diagnosis should be every time confirmed. Tw PCR assay is an important diagnostic tool but is not sufficient to establish the diagnosis and must be interpreted with histopathology and immunohistochemical testing results.

  11. Drilling induced damage of core samples. Evidences from laboratory testing and numerical modelling

    International Nuclear Information System (INIS)

    Lanaro, Flavio

    2008-01-01

    Extensive sample testing in uniaxial and Brazilian test conditions were carried out for the Shobasama and MIU Research Laboratory Site (Gifu Pref., Japan). The compressive and tensile strength of the samples was observed to be negatively correlated to the in-situ stress components. Such correlation was interpreted as stress-release induced sample damage. Similar stress conditions were then numerically simulated by means of the BEM-DDM code FRACOD 2D in plane strain conditions. This method allows for explicitly consider the influence of newly initiated or propagating fractures on the stress field and deformation of the core during drilling process. The models show that already at moderate stress levels some fracturing of the core during drilling might occur leading to reduced laboratory strength of the samples. Sample damage maps were produced independently from the laboratory test results and from the numerical models and show good agreement with each other. (author)

  12. Mycobacterium bovis in milk samples: a preliminary investigation using PCR

    International Nuclear Information System (INIS)

    Achel, D.G.; Gyamfi, O.K.; Broni, F.; Gomda, Y.; Brown, C.A.

    2007-01-01

    PCR was used to screen milk samples (n=41) for Mycobacterium bovis. DNA samples were obtained through concentration by 50% sucrose addition and centrifugation. Sixteen (16) samples (or 39%) were positive for M. Bovis DNA and the rest 25 (or 61%) were negative. All four kraals had some samples testing positive for M. bovis; the highest being 50% (5/10) and the lowest being 13% (2/15). (au)

  13. Testing of Alignment Parameters for Ancient Samples: Evaluating and Optimizing Mapping Parameters for Ancient Samples Using the TAPAS Tool

    Directory of Open Access Journals (Sweden)

    Ulrike H. Taron

    2018-03-01

    Full Text Available High-throughput sequence data retrieved from ancient or other degraded samples has led to unprecedented insights into the evolutionary history of many species, but the analysis of such sequences also poses specific computational challenges. The most commonly used approach involves mapping sequence reads to a reference genome. However, this process becomes increasingly challenging with an elevated genetic distance between target and reference or with the presence of contaminant sequences with high sequence similarity to the target species. The evaluation and testing of mapping efficiency and stringency are thus paramount for the reliable identification and analysis of ancient sequences. In this paper, we present ‘TAPAS’, (Testing of Alignment Parameters for Ancient Samples, a computational tool that enables the systematic testing of mapping tools for ancient data by simulating sequence data reflecting the properties of an ancient dataset and performing test runs using the mapping software and parameter settings of interest. We showcase TAPAS by using it to assess and improve mapping strategy for a degraded sample from a banded linsang (Prionodon linsang, for which no closely related reference is currently available. This enables a 1.8-fold increase of the number of mapped reads without sacrificing mapping specificity. The increase of mapped reads effectively reduces the need for additional sequencing, thus making more economical use of time, resources, and sample material.

  14. Estimation of AUC or Partial AUC under Test-Result-Dependent Sampling.

    Science.gov (United States)

    Wang, Xiaofei; Ma, Junling; George, Stephen; Zhou, Haibo

    2012-01-01

    The area under the ROC curve (AUC) and partial area under the ROC curve (pAUC) are summary measures used to assess the accuracy of a biomarker in discriminating true disease status. The standard sampling approach used in biomarker validation studies is often inefficient and costly, especially when ascertaining the true disease status is costly and invasive. To improve efficiency and reduce the cost of biomarker validation studies, we consider a test-result-dependent sampling (TDS) scheme, in which subject selection for determining the disease state is dependent on the result of a biomarker assay. We first estimate the test-result distribution using data arising from the TDS design. With the estimated empirical test-result distribution, we propose consistent nonparametric estimators for AUC and pAUC and establish the asymptotic properties of the proposed estimators. Simulation studies show that the proposed estimators have good finite sample properties and that the TDS design yields more efficient AUC and pAUC estimates than a simple random sampling (SRS) design. A data example based on an ongoing cancer clinical trial is provided to illustrate the TDS design and the proposed estimators. This work can find broad applications in design and analysis of biomarker validation studies.

  15. Acceptance of referral for partners by clients testing positive for human immunodeficiency virus

    Directory of Open Access Journals (Sweden)

    Netsanet F

    2013-01-01

    Full Text Available Fetene Netsanet,1 Ayalew Dessie21IMA World Health SuddHealth Multi Donor Trust Fund-Basic Package of Health Services Project, Juba, South Sudan; 2United States Agency for International Development, Private Health Sector Program, Abt Associates Inc, Addis Ababa, EthiopiaBackground: Human immunodeficiency virus (HIV-positive individuals who do not disclose their HIV status to their partners are more likely to present late for HIV and acquired immune deficiency syndrome (AIDS care than those who have disclosed their HIV status to their partners. A major area of challenge with regards to HIV counseling for clients is disclosure of their HIV status to their partners. The main methods of partner notification are patient referral, provider referral, contract referral, and outreach assistance. The emphasis on a plausible and comprehensive partner referral strategy for widespread positive case detection in resource-limited countries needs to be thought out and developed.Methods: A qualitative study was conducted among newly HIV-positive clients to identify partners for notification and acceptance of referral by their partners. Health service providers working in HIV testing and counseling clinics were also provided with semistructured questionnaires in order to assess their view towards partner notification strategies for clients testing positive for HIV.Results: Fifteen newly diagnosed HIV-positive clients were counseled to provide referral slips to their partners. All clients agreed and took the referral card. However, only eight were willing and actually provided the card to their partners. Five of the eight partners of clients who tested HIV-positive and who were provided with referral cards responded to the referral and were tested for HIV. Three were positive and two were negative. Nine of 11 counselors did not agree to requesting partner locator information from HIV-positive clients for contractual referral and/or outreach assistance. The findings

  16. The impact of screening-test negative samples not enumerated by MPN

    DEFF Research Database (Denmark)

    Corbellini, Luis Gustavo; Ribeiro Duarte, Ana Sofia; de Knegt, Leonardo

    2015-01-01

    that includes false negative results from the screening, and a third that considers the entire data set. The relative sensitivity of the screening test was also calculated assuming as gold standard samples with confirmed Salmonella. Salmonella was confirmed by a reference laboratory in 29 samples either...

  17. Miniaturized bead-beating device to automate full DNA sample preparation processes for gram-positive bacteria.

    Science.gov (United States)

    Hwang, Kyu-Youn; Kwon, Sung Hong; Jung, Sun-Ok; Lim, Hee-Kyun; Jung, Won-Jong; Park, Chin-Sung; Kim, Joon-Ho; Suh, Kahp-Yang; Huh, Nam

    2011-11-07

    We have developed a miniaturized bead-beating device to automate nucleic acids extraction from Gram-positive bacteria for molecular diagnostics. The microfluidic device was fabricated by sandwiching a monolithic flexible polydimethylsiloxane (PDMS) membrane between two glass wafers (i.e., glass-PDMS-glass), which acted as an actuator for bead collision via its pneumatic vibration without additional lysis equipment. The Gram-positive bacteria, S. aureus and methicillin-resistant S. aureus, were captured on surface-modified glass beads from 1 mL of initial sample solution and in situ lyzed by bead-beating operation. Then, 10 μL or 20 μL of bacterial DNA solution was eluted and amplified successfully by real-time PCR. It was found that liquid volume fraction played a crucial role in determining the cell lysis efficiency in a confined chamber by facilitating membrane deflection and bead motion. The miniaturized bead-beating operation disrupted most of S. aureus within 3 min, which turned out to be as efficient as the conventional benchtop vortexing machine or the enzyme-based lysis technique. The effective cell concentration was significantly enhanced with the reduction of initial sample volume by 50 or 100 times. Combination of such analyte enrichment and in situ bead-beating lysis provided an excellent PCR detection sensitivity amounting to ca. 46 CFU even for the Gram-positive bacteria. The proposed bead-beating microdevice is potentially useful as a nucleic acid extraction method toward a PCR-based sample-to-answer system. This journal is © The Royal Society of Chemistry 2011

  18. A CLASS OF DISTRIBUTION-FREE TESTS FOR INDEPENDENCE AGAINST POSITIVE QUADRANT DEPENDENCE

    Directory of Open Access Journals (Sweden)

    Parameshwar V Pandit

    2014-02-01

    Full Text Available A class of distribution-free tests based on convex combination of two U-statistics is considered for testing independence against positive quadrant dependence. The class of tests proposed by Kochar and Gupta (1987 and Kendall’s test are members of the proposed class. The performance of the proposed class is evaluated in terms of Pitman asymptotic relative efficiency for Block- Basu (1974 model and Woodworth family of distributions. It has been observed that some members of the class perform better than the existing tests in the literature.  Unbiasedness and consistency of the proposed class of tests have been established.

  19. Outcome in clients with positive pregnancy test following IVF/ICSI ...

    African Journals Online (AJOL)

    Background: A retrospective analysis of the outcome of all patients who have recorded a positive pregnancy test following IVF/ICSI treatment from June 1999 to December 2002 was done. Materials and Methods: A total of 1256 treatment cycles were carried out using the long day 1 (early follicular phase) or day 21 ...

  20. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  1. Poor Positive Predictive Value of Lyme Disease Serologic Testing in an Area of Low Disease Incidence.

    Science.gov (United States)

    Lantos, Paul M; Branda, John A; Boggan, Joel C; Chudgar, Saumil M; Wilson, Elizabeth A; Ruffin, Felicia; Fowler, Vance; Auwaerter, Paul G; Nigrovic, Lise E

    2015-11-01

    Lyme disease is diagnosed by 2-tiered serologic testing in patients with a compatible clinical illness, but the significance of positive test results in low-prevalence regions has not been investigated. We reviewed the medical records of patients who tested positive for Lyme disease with standardized 2-tiered serologic testing between 2005 and 2010 at a single hospital system in a region with little endemic Lyme disease. Based on clinical findings, we calculated the positive predictive value of Lyme disease serology. Next, we reviewed the outcome of serologic testing in patients with select clinical syndromes compatible with disseminated Lyme disease (arthritis, cranial neuropathy, or meningitis). During the 6-year study period 4723 patients were tested for Lyme disease, but only 76 (1.6%) had positive results by established laboratory criteria. Among 70 seropositive patients whose medical records were available for review, 12 (17%; 95% confidence interval, 9%-28%) were found to have Lyme disease (6 with documented travel to endemic regions). During the same time period, 297 patients with a clinical illness compatible with disseminated Lyme disease underwent 2-tiered serologic testing. Six of them (2%; 95% confidence interval, 0.7%-4.3%) were seropositive, 3 with documented travel and 1 who had an alternative diagnosis that explained the clinical findings. In this low-prevalence cohort, fewer than 20% of positive Lyme disease tests are obtained from patients with clinically likely Lyme disease. Positive Lyme disease test results may have little diagnostic value in this setting. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  2. Positron annihilation lifetime study of positive temperature coefficient BaTiO3 samples

    International Nuclear Information System (INIS)

    Ling Chen; Mingkang Teng; Guanghou Wang; Xiaoyun Li; Tianchang Lu

    1989-01-01

    In order to investigate the doped vacancies in BaTiO 3 samples as well as their influence on the positive temperature coefficient (PTC) the positron annihilation lifetime spectroscopy was applied. Two groups of BaTiO 3 samples with BaO excess were prepared by doping different concentrations of La 2 O 3 and Nb 2 O 5 , respectively in the range from 0.1 to 3 at%. A third group of samples of two Sb-doped PTC BaTiO 3 semiconductors with excess BaO or TiO 2 were studied by the aid of positron technique before and after being reduced. It is shown that the positron lifetime parameters are sensitive to changes in the vacancy concentration in BaTiO 3 ceramics near the 0.1 mol% region. But they are almost unchanged during reduction processing; the resistivity of samples changed by one to two orders of magnitude through the reduction. It can be concluded that the PTC effect is due to oxygen on the grain boundary rather than vacancies, and that the Heywang-Jonker model is more reasonable

  3. Evaluation of three sample preparation methods for the direct identification of bacteria in positive blood cultures by MALDI-TOF

    OpenAIRE

    Tanner, Hannah; Evans, Jason T.; Gossain, Savita; Hussain, Abid

    2017-01-01

    Background Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) w...

  4. [Positive Distribution Rate of Coombs Test in Patients with Clinical Anemia and Blood Transfusion and Its Effect on Clinical Blood Transfusion].

    Science.gov (United States)

    Wu, Gang; Duan, Yu-Han

    2018-02-01

    To study the positive distribution rate of Coombs test in patients with clinical anemia and blood transfusion, and its effect on clinical blood transfusion. Seventy patients with hemoglobin level in the normal range were enrolled into control group, while 130 patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel antihuman globin detection card and 70 surgical patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel anti-human globin card were enrolled into anemia or blood transfusion (A or BT) group. And coomb' s test performed for all the patients, in which the positive patients in Department of Internal Medicine need to be re-typed. Among 70 surgical patients with anemia or blood transfusion, 14 cases were directly detected to be anti-human globine positive with detection rate 20%; among 130 internal medicine patients with anemia or blood transfusion, 54 cases were directly detected to be anti-human globine positive with detection rate 41.4%. Among 270 cases, the highest positive rate (66.7%) was observed in patients with 50-59 g/L of hemoglobin. According to type test, the samples of 54 patients with anemia in Department of Internal Medicine, who were directly selected to be anti-human globin positive, could be divided into anti-C3d(7 cases, accounting for 13.0%), anti-IgG(12 cases accounting for, 22.2%) and anti-C3d+anti-IgG(35 cases, accounting for 64.8%), while according to diseases, the anti-human globin positive ratio was high in tumor cancer, hephropathy and gastroenteropathy patients, and patients in intensive care unit, moreover the blood transfusion frequency of these patients was higher than that of patients with anti-human globin negative(Pblood transfusion, so as to ensure the effectiveness of blood transfusion.

  5. Testing of a Microfluidic Sampling System for High Temperature Electrochemical MC&A

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Candido [Argonne National Lab. (ANL), Argonne, IL (United States); Nichols, Kevin [Argonne National Lab. (ANL), Argonne, IL (United States)

    2013-11-27

    This report describes the preliminary validation of a high-temperature microfluidic chip system for sampling of electrochemical process salt. Electroanalytical and spectroscopic techniques are attractive candidates for improvement through high-throughput sample analysis via miniaturization. Further, microfluidic chip systems are amenable to micro-scale chemical processing such as rapid, automated sample purification to improve sensor performance. The microfluidic chip was tested to determine the feasibility of the system for high temperature applications and conditions under which microfluidic systems can be used to generate salt droplets at process temperature to support development of material balance and control systems in a used fuel treatment facility. In FY13, the project focused on testing a quartz microchip device with molten salts at near process temperatures. The equipment was installed in glove box and tested up to 400°C using commercial thermal transfer fluids as the carrier phase. Preliminary tests were carried out with a low-melting halide salt to initially characterize the properties of this novel liquid-liquid system and to investigate the operating regimes for inducing droplet flow within candidate carrier fluids. Initial results show that the concept is viable for high temperature sampling but further development is required to optimize the system to operate with process relevant molten salts.

  6. For Men: A Positive Zika Virus Test, What Does It Mean for Me?

    Science.gov (United States)

    CDC’s Response to Zika FOR MEN: A POSITIVE ZIKA VIRUS TEST What does it mean for me? You’ ... Zika test result, which means that you have Zika virus. Zika is spread through mosquito bites and through ...

  7. Efficacy of immunoassay chromatography test for hepatitis-C antibodies detection

    International Nuclear Information System (INIS)

    Batool, A.; Khan, M.I.; Bano, K.A.

    2009-01-01

    To asses the efficacy of commercially available tests device method for anti HCV detection. Methods: Total 2000 blood samples for detection of anti HCV were screened initially by immuno chromatographic method. Those found positive on initial screening were re-tested by ELISA method at the Biochemistry Laboratory of the Pakistan Medical Research Council, Fatima Jinnah Medical College, Lahore. Results: Out of a total of 2,000 blood samples, 177 were found to be initially reactive/positive for anti-HCV with immuno chromatographic method. When these reactive/positive samples were retested for confirmation with ELISA, 47 blood samples were found to have tested falsely positive for anti-HCV. Overall 2.35% of blood samples were found to be tested false positive for anti-HCV by immuno chromatographic device method. Conclusions: Immuno chromatographic device method test is rapid and simple, which can be used in setting with limited facility when rapid testing is required. However it should not be used as sole criteria for diagnosis but should serve the purpose of initial screening only. Further research is required to establish the reliability of such devices for their specificity and sensitivity. (author)

  8. Analysis of small sample size studies using nonparametric bootstrap test with pooled resampling method.

    Science.gov (United States)

    Dwivedi, Alok Kumar; Mallawaarachchi, Indika; Alvarado, Luis A

    2017-06-30

    Experimental studies in biomedical research frequently pose analytical problems related to small sample size. In such studies, there are conflicting findings regarding the choice of parametric and nonparametric analysis, especially with non-normal data. In such instances, some methodologists questioned the validity of parametric tests and suggested nonparametric tests. In contrast, other methodologists found nonparametric tests to be too conservative and less powerful and thus preferred using parametric tests. Some researchers have recommended using a bootstrap test; however, this method also has small sample size limitation. We used a pooled method in nonparametric bootstrap test that may overcome the problem related with small samples in hypothesis testing. The present study compared nonparametric bootstrap test with pooled resampling method corresponding to parametric, nonparametric, and permutation tests through extensive simulations under various conditions and using real data examples. The nonparametric pooled bootstrap t-test provided equal or greater power for comparing two means as compared with unpaired t-test, Welch t-test, Wilcoxon rank sum test, and permutation test while maintaining type I error probability for any conditions except for Cauchy and extreme variable lognormal distributions. In such cases, we suggest using an exact Wilcoxon rank sum test. Nonparametric bootstrap paired t-test also provided better performance than other alternatives. Nonparametric bootstrap test provided benefit over exact Kruskal-Wallis test. We suggest using nonparametric bootstrap test with pooled resampling method for comparing paired or unpaired means and for validating the one way analysis of variance test results for non-normal data in small sample size studies. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. [The Amsterdam Dementia Screening Test in cognitively healthy and clinical samples. An update of normative data].

    Science.gov (United States)

    van Toutert, Meta; Diesfeldt, Han; Hoek, Dirk

    2016-10-01

    The six tests in the Amsterdam Dementia Screening Test (ADST) examine the cognitive domains of episodic memory (delayed picture recognition, word learning), orientation, category fluency (animals and occupations), constructional ability (figure copying) and executive function (alternating sequences). New normative data were collected in a sample of 102 elderly volunteers (aged 65-94), including subjects with medical or other health conditions, except dementia or frank cognitive impairment (MMSE > 24). Included subjects were independent in complex instrumental activities of daily living.Fluency, not the other tests, needed adjustment for age and education. A deficit score (0-1) was computed for each test. Summation (range 0-6) proved useful in differentiating patients with dementia (N = 741) from normal elderly (N = 102).Positive and negative predictive power across a range of summed deficit scores and base rates are displayed in Bayesian probability tables.In the normal elderly, delayed recall for eight words was tested and adjusted for initial recall. A recognition test mixed the target words with eight distractors. Delayed recognition was adjusted for immediate and delayed recall.The ADST and the normative data in this paper help the clinical neuropsychologist to make decisions concerning the presence or absence of neurocognitive disorder in individual elderly examinees.

  10. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    Science.gov (United States)

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.

  11. Evaluation of positive and false-positive results in syphilis screening of blood donors in Rio de Janeiro, Brazil.

    Science.gov (United States)

    Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R

    2017-06-01

    We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.

  12. Pilot evaluation of the Computer-Based Assessment for Sampling Personal Characteristics test.

    Science.gov (United States)

    Shipper, Edward S; Mazer, Laura M; Merrell, Sylvia Bereknyei; Lin, Dana T; Lau, James N; Melcher, Marc L

    2017-07-01

    High attrition rates hint at deficiencies in the resident selection process. The evaluation of personal characteristics representative of success is difficult. Here, we evaluate a novel tool for assessing personal characteristics. To evaluate feasibility, we used an anonymous voluntary survey questionnaire offered to study participants before and after contact with the CASPer test. To evaluate the CASPer test as a predictor of success, we compared CASPer test assessments of personal characteristics versus traditional faculty assessment of personal characteristics with applicant rank list position. All applicants (n = 77) attending an in-person interview for general surgery residency, and all faculty interviewers (n = 34) who reviewed these applications were invited to participate. Among applicants, 84.4% of respondents (65 of 77) reported that a requirement to complete the CASPer test would have no bearing or would make them more likely to apply to the program (mean = 3.30, standard deviation = 0.96). Among the faculty, 62.5% respondents (10 of 16) reported that the same condition would have no bearing or would make applicants more likely to apply to the program (mean = 3.19, standard deviation = 1.33). The Spearman's rank-order correlation coefficients for the relationships between traditional faculty assessment of personal characteristics and applicant rank list position, and novel CASPer assessment of personal characteristics and applicant rank list position, were -0.45 (P = 0.033) and -0.41 (P = 0.055), respectively. The CASPer test may be feasibly implemented as component of the resident selection process, with the potential to predict applicant rank list position and improve the general surgery resident selection process. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Non-destructive identification of micrometer-scale minerals and their position within a bulk sample

    DEFF Research Database (Denmark)

    Sørensen, Henning O.; Hakim, Sepide S.; Pedersen, Stefan

    2012-01-01

    . Crushing or disintegrating a sample annihilates any possibility for gathering information from the texture of the porous media or the mineral assemblage close to the grains in question. A new method using three-dimensional X-ray diffraction (3DXRD) microscopy can be successfully applied to natural...... materials. We combined X-ray microtomography (XMT) and 3DXRD to investigate a sample of very fine-grained chalk containing fracture minerals. The XMT technique provides three-dimensional images of the particles and pore structure at very high resolution (350 nm voxel dimension) on samples less than 500 μm......Using the conventional techniques of mineralogy, it has been a challenge to determine mineral identity, crystal orientation and spatial position of micrometer-sized crystals that are embedded in a rock, sediment or soil. Traditionally, the individual grains must be extracted and analyzed separately...

  14. A Note on Confidence Interval for the Power of the One Sample Test

    Directory of Open Access Journals (Sweden)

    A. Wong

    2010-01-01

    Full Text Available In introductory statistics texts, the power of the test of a one-sample mean when the variance is known is widely discussed. However, when the variance is unknown, the power of the Student's -test is seldom mentioned. In this note, a general methodology for obtaining inference concerning a scalar parameter of interest of any exponential family model is proposed. The method is then applied to the one-sample mean problem with unknown variance to obtain a (1−100% confidence interval for the power of the Student's -test that detects the difference (−0. The calculations require only the density and the cumulative distribution functions of the standard normal distribution. In addition, the methodology presented can also be applied to determine the required sample size when the effect size and the power of a size test of mean are given.

  15. Failure analysis of burst tested fuel tube samples

    International Nuclear Information System (INIS)

    Padmaprabu, C.; Ramana Rao, S.V.; Srivatsava, R.K.

    2005-01-01

    The Total Circumferential Elongation (TCE) is an important parameter for evaluation of ductility of the Zircaloy-4 fuel tubes for the PHWR reactors. The TCE values of the fuel tubes were obtained using the burst testing technique. In some lots there is a variation in the values of the TCE. To investigate the reasons for such a large variation in the TCE, samples were selected at appropriate intervals and sectioned at the fractured portion. The surface morphology of the fractured surfaces was examined under Scanning Electron Microscope (SEM) equipped with Energy Dispersive Spectrometer (EDS). The morphologies show segregation of elements at specific locations. Energy dispersive spectra was obtained from those segregated particles. According to the magnitude of TCE value the samples were classified into low, intermediate and high ductility. Low ductility samples were found to contain large amount of segregations along the thickness direction of the tube. This forms a brittle region and a path for the easy crack growth along thickness direction. In the case of intermediate samples the segregation occurred in fewer locations compared to low ductile samples and also confined to the circumferential direction of the outside surface of the tube. Due to this, probability of crack formation at the surface of the tube could be high. But crack growth would be slower in the ductile matrix along the thickness direction resulting in the enhancement of TCE value compared to the low ductile sample. In the high ductile samples, the segregations were very scarce and found to be isolated and embedded in the ductile matrix. The mode of failure in these types of samples was found to be purely ductile. Cracks were found to originate solely from the micro voids in the material. As the probability of crack formation and its propagation is low, very high TCE values were observed in these samples. Microstructural observations of fractured surfaces and EDAX analysis was able to identify the

  16. High resolution multiple sampling ionization chamber (MUSIC) sensitive to position coordinates

    International Nuclear Information System (INIS)

    Petrascu, H.; Kumagai, H.; Tanihata, I.; Petrascu, M.

    1999-01-01

    A new type of MUSIC sensitive to position coordinates is reported. The development of the first version of this type of chamber is based on the principles presented by Badhwar in 1973. The present detector will be used in experiments on fusion by using radioactive beams. This chamber due to the high resolution is suitable to identification and tracking of low Z particles. One of our goals, when we started this work, was to reduce as much as possible the Z value of particles that can be 'seen' by an ionization chamber. The resolution of the chamber was significantly improved by connecting the preamplifiers directly to the MUSIC's pads. These preamplifiers are able to work in vacuum and very low gas pressure. In this way the value of signal to noise ratio was increased by a factor of ∼10. The detector is of Frisch grid type, with the anode split into 10 active pads. It is the first model of a MUSIC with the field shared between the position grid and the anode pads. The Frisch grid was necessary because the detector is originally designed for very accurate energy measurements and particle identification. A drawing of this detector is shown. The detector itself consists of four main parts. The first one is the constant field-gradient cage, sandwiched in between the cathode and the Frisch grid. The second is the Frisch grid. The third is the position grid located under the Frisch grid. The last one is the plate with the anode pads. The cage is made of 100 μm Cu-Be wires. Every wire was tensioned with a weight representing half of its breaking limit. The Frisch grid was done on an aluminium frame, on which 20 μm W wires spaced 0.3 mm, were wound. For the position grid, 10 groups of 20 μm gold plated W wires have been used. Each group consisted of 5 wires spaced 0.9 mm and connected in parallel. The anode pads 7.8 x 60 mm 2 were perpendicular to the beam direction. Each pad and each of the position wire groups were connected to a preamplifier. The energy resolution

  17. A comparative study of the typhidot (Dot-EIA) and Widal tests in blood culture positive cases of typhoid fever.

    Science.gov (United States)

    Khoharo, Haji Khan

    2011-07-01

    Seventy-six blood culture positive typhoid cases and forty-eight controls were studied. The typhidot test was positive in 74 (97.36%) cases, with a sensitivity, specificity and positive predictive value of 96%, 89.5%, and 95%, respectively, compared to the Widal test which was positive in 56 (73.68%) cases with a sensitivity, specificity, and positive predictive value of 72%, 87%, and 87%, respectively (P = 0.001). In the control group, seven (14.5%) cases tested positive for the Widal test and two (4.16%) for the typhidot (P = 0.001), yielding the sensitivity and specificity for the Widal test and the typhidot test of 63% and 83%, and 85% and 97%, respectively. We conclude that the Dot-EIA (enzyme immunoassay; typhidot) is a more sensitive and specific test which is easy to perform and more reliable compared to the Widal test and that it is useful in early therapy.

  18. Group Systematic Desensitization Versus Covert Positive Reinforcement in the Reduction of Test Anxiety

    Science.gov (United States)

    Kostka, Marion P.; Galassi, John P.

    1974-01-01

    The study compared modified versions of systematic desensitization and covert positive reinforcement to a no-treatment control condition in the reduction of test anxiety. On an anagrams performance test, the covert reinforcement and control groups were superior to the desensitization group. (Author)

  19. False-positive results after environmental pinworm PCR testing due to Rhabditid nematodes in Corncob bedding.

    Science.gov (United States)

    Leblanc, Mathias; Berry, Kristina; Graciano, Sandy; Becker, Brandon; Reuter, Jon D

    2014-11-01

    Modern rodent colonies are housed in individually ventilated cages to protect the animals from contamination with adventitious pathogens. Standard health monitoring through soiled-bedding sentinels does not always detect infections, especially in the context of low pathogen prevalence. Recently proposed alternatives include analyzing environmental samples from the cages or rack exhaust by PCR to improve the detection of rodent pathogens but optimal sampling strategies have not yet been established for different microorganisms. Although generally very sensitive and specific, these molecular assays are not foolproof and subject to false-positive and -negative results and should always be interpreted cautiously with an overall understanding of the intrinsic controls and all the variables that may affect the results. Here, we report a limited Aspiculuris tetraptera outbreak in a mouse barrier facility that was detected by fecal PCR in sentinels and confirmed by fecal flotation and direct cecal examination of both sentinels and colony animals. The outbreak led to a widespread survey of all facilities for pinworms by using environmental PCR from ventilated rack exhaust plenums. Environmental PCR suggested an unexpected widespread contamination of all ventilated racks holding nonautoclaved cages, but results could not be confirmed in sentinel or colony animals by fecal flotation, cecal and colonic examination, or cage PCR testing. After additional investigation, the unexpected environmental PCR results were confirmed as false-positive findings due to the nonspecificity of the assay, leading to the amplification of rhabditid nematodes, which are not infectious in rodents but which contaminated the corncob bedding.

  20. Investigating Psychometric Properties of the Persian Version of Positive Psychotherapy Inventory

    Directory of Open Access Journals (Sweden)

    Z Ghorbani

    2015-08-01

    Full Text Available The purpose of the study was to investigate psychometric properties of the Persian version of positive psychotherapy inventory in university students. Research method was descriptive, correlational type. The sample of the study consist of 432 MS and PhD students, 225 female and 207 male, aged between 23 to 45 of state universities of Tehran who were selected through multi-stage random sampling. To study reliability, convergent and structural validity of instrument the sample group completed, positive psychotherapy inventory (Rashid and Oxford Happiness Inventory (Argyle and Hills. To investigating the reliability Cronbach alpha and test- retest method, and for validity of instrument structural validity exploratory factor analysis method and convergent validity were used. Results showed the total internal consistency of positive psychotherapy inventory was 0.80 and subscales internal consistency was between 0.80 to 0.92 respectively. In addition test-retest reliability coefficient was 0.70 for total inventory and between 0.63 to 0.73 for the subscales. Also the correlation coefficients between positive psychotherapy inventory and oxford happiness inventory were 0.73, which indicated a satisfactory convergent validity for positive psychotherapy inventory. Confirmatory factor analysis results showed three factors model of positive psychotherapy inventory in the Iranian sample. These three factors explained 79.99 variance of total inventory.

  1. Power and sample size evaluation for the Cochran-Mantel-Haenszel mean score (Wilcoxon rank sum) test and the Cochran-Armitage test for trend.

    Science.gov (United States)

    Lachin, John M

    2011-11-10

    The power of a chi-square test, and thus the required sample size, are a function of the noncentrality parameter that can be obtained as the limiting expectation of the test statistic under an alternative hypothesis specification. Herein, we apply this principle to derive simple expressions for two tests that are commonly applied to discrete ordinal data. The Wilcoxon rank sum test for the equality of distributions in two groups is algebraically equivalent to the Mann-Whitney test. The Kruskal-Wallis test applies to multiple groups. These tests are equivalent to a Cochran-Mantel-Haenszel mean score test using rank scores for a set of C-discrete categories. Although various authors have assessed the power function of the Wilcoxon and Mann-Whitney tests, herein it is shown that the power of these tests with discrete observations, that is, with tied ranks, is readily provided by the power function of the corresponding Cochran-Mantel-Haenszel mean scores test for two and R > 2 groups. These expressions yield results virtually identical to those derived previously for rank scores and also apply to other score functions. The Cochran-Armitage test for trend assesses whether there is an monotonically increasing or decreasing trend in the proportions with a positive outcome or response over the C-ordered categories of an ordinal independent variable, for example, dose. Herein, it is shown that the power of the test is a function of the slope of the response probabilities over the ordinal scores assigned to the groups that yields simple expressions for the power of the test. Copyright © 2011 John Wiley & Sons, Ltd.

  2. APTIMA assay on SurePath liquid-based cervical samples compared to endocervical swab samples facilitated by a real time database

    Directory of Open Access Journals (Sweden)

    Khader Samer

    2010-01-01

    Full Text Available Background: Liquid-based cytology (LBC cervical samples are increasingly being used to test for pathogens, including: HPV, Chlamydia trachomatis (CT and Neisseria gonorrhoeae (GC using nucleic acid amplification tests. Several reports have shown the accuracy of such testing on ThinPrep (TP LBC samples. Fewer studies have evaluated SurePath (SP LBC samples, which utilize a different specimen preservative. This study was undertaken to assess the performance of the Aptima Combo 2 Assay (AC2 for CT and GC on SP versus endocervical swab samples in our laboratory. Materials and Methods: The live pathology database of Montefiore Medical Center was searched for patients with AC2 endocervical swab specimens and SP Paps taken the same day. SP samples from CT- and/or GC-positive endocervical swab patients and randomly selected negative patients were studied. In each case, 1.5 ml of the residual SP vial sample, which was in SP preservative and stored at room temperature, was transferred within seven days of collection to APTIMA specimen transfer tubes without any sample or patient identifiers. Blind testing with the AC2 assay was performed on the Tigris DTS System (Gen-probe, San Diego, CA. Finalized SP results were compared with the previously reported endocervical swab results for the entire group and separately for patients 25 years and younger and patients over 25 years. Results: SP specimens from 300 patients were tested. This included 181 swab CT-positive, 12 swab GC-positive, 7 CT and GC positive and 100 randomly selected swab CT and GC negative patients. Using the endocervical swab results as the patient′s infection status, AC2 assay of the SP samples showed: CT sensitivity 89.3%, CT specificity 100.0%; GC sensitivity and specificity 100.0%. CT sensitivity for patients 25 years or younger was 93.1%, versus 80.7% for patients over 25 years, a statistically significant difference (P = 0.02. Conclusions: Our results show that AC2 assay of 1.5 ml SP

  3. Triage of HR-HPV positive women with minor cytological abnormalities: a comparison of mRNA testing, HPV DNA testing, and repeat cytology using a 4-year follow-up of a population-based study.

    Science.gov (United States)

    Persson, Maria; Elfström, K Miriam; Brismar Wendel, Sophia; Weiderpass, Elisabete; Andersson, Sonia

    2014-01-01

    Expression of the viral E6/E7 oncogenes of high-risk human papillomaviruses (HR-HPV) is necessary for malignant conversion and maintenance in cervical tissue. In order to determine whether HR-HPV E6/E7 mRNA testing more effectively predicts precancerous lesions and invasive cervical cancer than HR-HPV DNA testing, we aimed to compare triage using HR-HPV E6/E7 mRNA testing by APTIMA HPV Assay (APTIMA) to HPV16 DNA testing, HPV16/18 DNA testing, and repeat cytology. Liquid-based (PreservCyt) cell samples were obtained from HR-HPV-positive women diagnosed with atypical squamous cells of undetermined significance (ASCUS) and low-grade squamous intraepithelial lesions (LSIL) within the framework of the population-based cervical cancer screening program in Stockholm, Sweden. Samples were tested for HR-HPV E6/E7 mRNA by APTIMA (Gene-Probe Inc., San Diego, CA, USA). Women were followed up for 4 years after the index cytology via medical and laboratory records, and the Stockholm Oncology Center. Nine of 25 (36%) women in the ASCUS group, and 64 of 180 (36%) women in the LSIL group developed cervical intraepithelial neoplasia (CIN) grade 2 or worse during 4 years of follow-up. 162 (74%) women were APTIMA-positive, and APTIMA had the highest sensitivity to predict CIN2 or worse and CIN3 or worse in the ASCUS (77.8% and 100%) and LSIL (78.1 and 75.8%) groups, although specificity was insufficient (cytology were more specific than APTIMA. The results of this population-based study with comprehensive follow-up support the use of APTIMA as a triage test for women with ASCUS. More focused investigation is required for women with LSIL.

  4. Testing results of Monte Carlo sampling processes in MCSAD

    International Nuclear Information System (INIS)

    Pinnera, I.; Cruz, C.; Abreu, Y.; Leyva, A.; Correa, C.; Demydenko, C.

    2009-01-01

    The Monte Carlo Simulation of Atom Displacements (MCSAD) is a code implemented by the authors to simulate the complete process of atom displacement (AD) formation. This code makes use of the Monte Carlo (MC) method to sample all the processes involved in the gamma and electronic radiation transport through matter. The kernel of the calculations applied to this code relies on a model based on an algorithm developed by the authors, which firstly splits out multiple electron elastic scattering events from those single ones at higher scattering angles and then, from the last one, sampling those leading to AD at high transferred atomic recoil energies. Some tests have been developed to check the sampling algorithms with the help of the corresponding theoretical distribution functions. Satisfactory results have been obtained, which indicate the strength of the methods and subroutines used in the code. (Author)

  5. PAL-XFEL cavity beam position monitor pick-up design and beam test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sojeong, E-mail: sojung8681@postech.ac.kr; Park, Young Jung; Kim, Changbum; Kim, Seung Hwan; Shin, Dong Cheol; Han, Jang-Hui; Ko, In Soo

    2016-08-11

    As an X-ray Free Electron Laser, PAL-XFEL is about to start beam commissioning. X-band cavity beam position monitor (BPM) is used in the PAL-XFEL undulator beam line. Prototypes of cavity BPM pick-up were designed and fabricated to test the RF characteristics. Also, the beam test of a cavity BPM pick-up was done in the Injector Test Facility (ITF). In the beam test, the raw signal properties of the cavity BPM pick-up were measured at a 200 pC bunch charge. According to the RF test and beam test results, the prototype cavity BPM pick-up design was confirmed to meet the requirements of the PAL-XFEL cavity BPM system.

  6. June 2012 Groundwater Sampling at the Central Nevada Test Area (Data Validation Package)

    International Nuclear Information System (INIS)

    2013-01-01

    The U.S. Department of Energy Office of Legacy Management conducted annual sampling at the Central Nevada Test Area (CNTA) on June 26-27, 2012, in accordance with the 2004 Correction Action Decision Document/Corrective Action Plan for Corrective Action Unit 443: Central Nevada Test Area (CNTA)-Subsurface and the addendum to the 'Corrective Action Decision Document/Corrective Action Plan' completed in 2008. Sampling and analysis were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PLN/S04351), continually updated).

  7. May 2011 Groundwater Sampling at the Central Nevada Test Area (Data Validation Package)

    International Nuclear Information System (INIS)

    2011-01-01

    The U.S. Department of Energy Office of Legacy Management conducted annual sampling at the Central Nevada Test Area (CNTA) on May 10-11, 2011, in accordance with the 2004 Correction Action Decision Document/Corrective Action Plan for Corrective Action Unit 443: Central Nevada Test Area (CNTA)-Subsurface and the addendum to the 'Corrective Action Decision Document/Corrective Action Plan' completed in 2008. Sampling and analysis were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PLN/S04351), continually updated)

  8. Characterization of human organ donors testing positive for type 1 diabetes-associated autoantibodies

    Science.gov (United States)

    Wiberg, A; Granstam, A; Ingvast, S; Härkönen, T; Knip, M; Korsgren, O; Skog, O

    2015-01-01

    In this study we aim to describe the characteristics of non-diabetic organ donors with circulating diabetes-associated autoantibodies collected within the Nordic Network for Islet Transplantation. One thousand and thirty organ donors have been screened in Uppsala for antibodies against glutamic acid decarboxylase (GADA) and islet antigen-2 (IA-2A). The 32 non-diabetic donors that tested positive for GADA (3·3% of all non-diabetic donors) were studied in more detail, together with 32 matched controls. Mean age among the autoantibody-positive donors was 52·6 (range 21–74), family history of type 1 diabetes (T1D) was unknown, and no donor was genetically predisposed for T1D regarding the human leucocyte antigen (HLA) locus. Subjects were analysed for islet cell antibodies (ICA), insulin autoantibodies (IAA) and zinc transporter 8 antibodies (ZnT8A), and pancreas morphology and clinical data were examined. Eight non-diabetic donors tested positive for two antibodies and one donor tested positive for four antibodies. No insulitis or other signs of a diabetic process were found in any of the donors. While inflammatory cells were present in all donors, subjects with high GADA titres had significantly higher CD45 cell numbers in exocrine tissue than controls. The extent of fibrosis was more pronounced in autoantibody-positive donors, even in subjects with lower GADA titres. Notably, it is possible that events not related directly to T1D (e.g. subclinical pancreatitis) may induce autoantibodies in some cases. PMID:26313035

  9. Testes cutâneos de hipersensibilidade imediata com o evoluir da idade Positive skin test and age

    Directory of Open Access Journals (Sweden)

    Wilma Carvalho Neves Forte

    2001-04-01

    Full Text Available OBJETIVO: avaliação da positividade aos testes cutâneos de hipersensibilidade imediata em crianças com asma brônquica e/ou rinite alérgica em diferentes faixas etárias. CASUÍSTICA E MÉTODOS: foi observada a positividade aos testes cutâneos de hipersensibilidade imediata, por testes de puntura, frente a diferentes alérgenos de mesma procedência: poeira total e Dermatophagóides sp, Dermatophagoides pteronyssinus, Dermatophagoides farinae e Blomia tropicalis, Penicillium sp, Alternaria alternata, Cladosporium herbarium, Aspergillus fumigatus, grama bermuda, capim de pasto, epitélio de cão, epitélio de gato, penas, Blatella germanica, lã. Foram selecionadas 713 crianças divididas em grupos conforme a faixa etária: grupo I (6 a 11 meses, II (1 a 3 anos e 11 meses, III (4 a 8 anos e 11 meses e IV (9 a 15 anos. Para análise estatística utilizou-se o cálculo do qui-quadrado. RESULTADOS: o total de diferenças significativas entre os vários grupos foi: I e II = 5; II e III = 5; II e IV = 5; III e IV = 6; I e III = 10 e I e IV = 10 CONCLUSÃO: concluiu-se que a positividade ao teste de hipersensibilidade imediata foi maior com o evoluir da idade, havendo positividade já aos doze meses de vida, sendo esta positividade significativamente maior a partir de quatro anos de idade.OBJECTIVE: to evaluate positive responses to skin tests for immediate hypersensitivity to allergens in children with asthma and rhinitis at different ages. METHOD: we observed positive skin test reactivity in prick tests using fifteen allergens of same origin (total dust and Dermatophagoides sp.; Dermatophagoides pteronyssinus; Dermatophagoides farinae; Blomia tropicalis; Penicillium sp; Alternaria alternata; Cladosporium herbarium; Aspergillus fumigatus; Bermuda grass; forage grass; dog and cat epithelia; feathers; Blatella germanica and wool. We placed 713 selected patients into different age groups - Group I: 6 to 11 months; Group II: 1 to 3 years and 11

  10. Diagnostic-test evaluation of immunoassays for anti-Toxoplasma gondii IgG antibodies in a random sample of Mexican population.

    Science.gov (United States)

    Caballero-Ortega, Heriberto; Castillo-Cruz, Rocío; Murieta, Sandra; Ortíz-Alegría, Luz Belinda; Calderón-Segura, Esther; Conde-Glez, Carlos J; Cañedo-Solares, Irma; Correa, Dolores

    2014-05-14

    There are few articles on evaluation of Toxoplasma gondii serological tests. Besides, commercially available tests are not always useful and are expensive for studies in open population. The aim of this study was to evaluate in-house ELISA and western blot for IgG antibodies in a representative sample of people living in Mexico. Three hundred and five serum samples were randomly selected from two national seroepidemiological survey banks; they were taken from men and women of all ages and from all areas of the country. ELISA cut-off was established using the mean plus three standard deviations of negative samples. Western blots were analysed by two experienced technicians and positivity was established according to the presence of at least three diagnostic bands. A commercial ELISA kit was used as a third test. Two reference standards were built up: one using concordant results of two assays leaving the evaluated test out and the other in which the evaluated test was included (IN) with at least two concordant results to define diagnosis. the lowest values of diagnostic parameters were obtained with the OUT reference standards: in-house ELISA had 96.9% sensitivity, 62.1% specificity, 49.6% PPV, 98.1% NPV and 71.8% accuracy, while western blot presented 81.8%, 89.7%, 84.0%, 88.2% and 86.6% values and the best kappa coefficient (0.72-0.82). The in-house ELISA is useful for screening people of Mexico, due to its high sensitivity, while western blot may be used to confirm diagnosis. These techniques might prove useful in other Latin American countries.

  11. A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler

    International Nuclear Information System (INIS)

    Chen, L B; Liu, S X; Gu, K X; Zhou, Y; Wang, J J

    2015-01-01

    This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper. (paper)

  12. DWPF Sample Vial Insert Study-Statistical Analysis of DWPF Mock-Up Test Data

    International Nuclear Information System (INIS)

    Harris, S.P.

    1997-01-01

    This report is prepared as part of Technical/QA Task Plan WSRC-RP-97-351 which was issued in response to Technical Task Request HLW/DWPF/TTR-970132 submitted by DWPF. Presented in this report is a statistical analysis of DWPF Mock-up test data for evaluation of two new analytical methods which use insert samples from the existing HydragardTM sampler. The first is a new hydrofluoric acid based method called the Cold Chemical Method (Cold Chem) and the second is a modified fusion method.Both new methods use the existing HydragardTM sampler to collect a smaller insert sample from the process sampling system. The insert testing methodology applies to the DWPF Slurry Mix Evaporator (SME) and the Melter Feed Tank (MFT) samples. Samples in small 3 ml containers (Inserts) are analyzed by either the cold chemical method or a modified fusion method. The current analytical method uses a HydragardTM sample station to obtain nearly full 15 ml peanut vials. The samples are prepared by a multi-step process for Inductively Coupled Plasma (ICP) analysis by drying, vitrification, grinding and finally dissolution by either mixed acid or fusion. In contrast, the insert sample is placed directly in the dissolution vessel, thus eliminating the drying, vitrification and grinding operations for the Cold chem method. Although the modified fusion still requires drying and calcine conversion, the process is rapid due to the decreased sample size and that no vitrification step is required.A slurry feed simulant material was acquired from the TNX pilot facility from the test run designated as PX-7.The Mock-up test data were gathered on the basis of a statistical design presented in SRT-SCS-97004 (Rev. 0). Simulant PX-7 samples were taken in the DWPF Analytical Cell Mock-up Facility using 3 ml inserts and 15 ml peanut vials. A number of the insert samples were analyzed by Cold Chem and compared with full peanut vial samples analyzed by the current methods. The remaining inserts were analyzed by

  13. Air-deployable oil spill sampling devices review phase 2 testing. Volume 1

    International Nuclear Information System (INIS)

    Hawke, L.; Dumouchel, A.; Fingas, M.; Brown, C.E.

    2007-01-01

    SAIC Canada tested air deployable oil sampling devices for the Emergencies Science and Technology Division of Environment Canada in order to determine the applicability and status of these devices. The 3 devices tested were: Canada's SABER (sampling autonomous buoy for evidence recovery), the United States' POPEIE (probe for oil pollution evidence in the environment); and, Sweden's SAR Floatation 2000. They were tested for buoyancy properties, drift behaviour and sampler sorbent pickup ratios. The SAR and SABER both had lesser draft and greater freeboard, while the POPEIE had much greater draft than freeboard. All 3 devices could be used for oil sample collection in that their drift characteristics would allow for the SABER and SAR devices to be placed upwind of the slick while the POPEIE device could be placed downwind of an oil spill. The sorbent testing revealed that Sefar sorbent and Spectra sorbent used in the 3 devices had negative pickup ratios for diesel but performance improved as oil viscosity increased. Both sorbents are inert and capable of collecting oil in sufficient volumes for consistent fingerprinting analysis. 10 refs., 8 tabs., 8 figs

  14. Center not liable for defamation from false-positive hepatitis test.

    Science.gov (United States)

    1997-04-18

    The Nebraska Court of Appeals ruled that [name removed] does not have a cause of action against the Lincoln Plasma Center in Lincoln, NE. The center blacklisted him as a carrier of hepatitis B virus; subsequent tests proved [name removed] was uninfected. [Name removed], a paid plasma donator, was placed on an ineligible list after he tested positive for the hepatitis B surface antigen. [Name removed] sued, alleging that Lincoln defamed him by publishing false information to blood banks about his eligibility to donate. The Court of Appeals upheld a trial court's directed verdict because there was no evidence that the plasma center acted in malice.

  15. 40 CFR 205.57-2 - Test vehicle sample selection.

    Science.gov (United States)

    2010-07-01

    ... pursuant to a test request in accordance with this subpart will be selected in the manner specified in the... then using a table of random numbers to select the number of vehicles as specified in paragraph (c) of... with the desig-nated AQL are contained in Appendix I, -Table II. (c) The appropriate batch sample size...

  16. Yoga and positive body image: A test of the Embodiment Model.

    Science.gov (United States)

    Mahlo, Leeann; Tiggemann, Marika

    2016-09-01

    The study aimed to test the Embodiment Model of Positive Body Image (Menzel & Levine, 2011) within the context of yoga. Participants were 193 yoga practitioners (124 Iyengar, 69 Bikram) and 127 university students (non-yoga participants) from Adelaide, South Australia. Participants completed questionnaire measures of positive body image, embodiment, self-objectification, and desire for thinness. Results showed yoga practitioners scored higher on positive body image and embodiment, and lower on self-objectification than non-yoga participants. In support of the embodiment model, the relationship between yoga participation and positive body image was serially mediated by embodiment and reduced self-objectification. Although Bikram practitioners endorsed appearance-related reasons for participating in yoga more than Iyengar practitioners, there were no significant differences between Iyengar and Bikram yoga practitioners on body image variables. It was concluded that yoga is an embodying activity that can provide women with the opportunity to cultivate a favourable relationship with their body. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. True positivity of anti-Hepatitis C Virus Enzyme-linked immunosorbent assay reactive blood donors: A prospective study done in western India

    Directory of Open Access Journals (Sweden)

    Sunita Tulsiani

    2012-01-01

    Full Text Available Background: A significant number of safe donations are removed from the blood supply, because of the reactive anti-HCV screening test results. This study aimed to assess if the HCV (Hepatitis C Virus seropositive donors were confirmed positive or not. Materials and Methods: More than 68,000 blood donors′ samples were routinely screened and 140 samples were found to be anti-HCV ELISA reactive. These 140 samples were tested by NAT. The NAT negative samples were tested by RIBA. Analysis of samples reactive in single ELISA kit vs. two ELISA kits was done. Results: Out of 140 anti-HCV ELISA reactive samples, a total of 16 (11.43% were positive by NAT. The results of 124 RIBA showed 6 (4.84% positive, 92 (74.19% negative, and 26 (20.97% indeterminate results. None of the sample which was reactive in only single ELISA kit was positive by NAT or RIBA. Conclusion: Only a minority of blood donors with repeatedly reactive anti-HCV screening test is positive by confirmatory testing, but all these blood units are discarded as per existing legal provisions in India. Efforts should be made to retain these donors and also donor units.

  18. Time-to-positivity, type of culture media and oxidase test performed on positive blood culture vials to predict Pseudomonas aeruginosa in patients with Gram-negative bacilli bacteraemia.

    Science.gov (United States)

    Cobos-Triguero, N; Zboromyrska, Y; Morata, L; Alejo, I; De La Calle, C; Vergara, A; Cardozo, C; Arcas, M P; Soriano, A; Marco, F; Mensa, J; Almela, M; Martínez, J A

    2017-02-01

    The aim of this study was to determine the usefulness of oxidase test and time-to-positivity (TTP) in aerobic and anaerobic blood culture vials to detect the presence of Pseudomonas aeruginosa in patients with Gram-negative bacilli (GNB) bacteraemia. TTP was recorded for each aerobic and anaerobic blood culture vial of monomicrobial bacteraemia due to GNB. Oxidase test was performed in a pellet of the centrifuged content of the positive blood culture. An algorithm was developed in order to perform the oxidase test efficiently taking into account TTP and type of vial. A total of 341 episodes of GNB bacteraemia were analysed. Sensitivity, specificity, positive predictive value and negative predictive value of the oxidase test performed on positive vials with GNB to predict P. aeruginosa were 95%, 99%, 91%, and 99%, respectively. When growth was first or exclusively detected in anaerobic vials, P. aeruginosa was never identified hence the performance of the oxidase test could be avoided. When growth was only or first detected in aerobic vials, a TTP≥8h predicted P. aeruginosa in 37% or cases (63 of 169), therefore oxidase test is highly recommended. Oxidase test performed onto positive blood culture vials previously selected by TTP and type of vials is an easy and inexpensive way to predict P. aeruginosa. In most cases, this can lead to optimization of treatment in less than 24 hours.

  19. Autonomous site selection and instrument positioning for sample acquisition

    Science.gov (United States)

    Shaw, A.; Barnes, D.; Pugh, S.

    The European Space Agency Aurora Exploration Program aims to establish a European long-term programme for the exploration of Space, culminating in a human mission to space in the 2030 timeframe. Two flagship missions, namely Mars Sample Return and ExoMars, have been proposed as recognised steps along the way. The Exomars Rover is the first of these flagship missions and includes a rover carrying the Pasteur Payload, a mobile exobiology instrumentation package, and the Beagle 2 arm. The primary objective is the search for evidence of past or present life on mars, but the payload will also study the evolution of the planet and the atmosphere, look for evidence of seismological activity and survey the environment in preparation for future missions. The operation of rovers in unknown environments is complicated, and requires large resources not only on the planet but also in ground based operations. Currently, this can be very labour intensive, and costly, if large teams of scientists and engineers are required to assess mission progress, plan mission scenarios, and construct a sequence of events or goals for uplink. Furthermore, the constraints in communication imposed by the time delay involved over such large distances, and line-of-sight required, make autonomy paramount to mission success, affording the ability to operate in the event of communications outages and be opportunistic with respect to scientific discovery. As part of this drive to reduce mission costs and increase autonomy the Space Robotics group at the University of Wales, Aberystwyth is researching methods of autonomous site selection and instrument positioning, directly applicable to the ExoMars mission. The site selection technique used builds on the geometric reasoning algorithms used previously for localisation and navigation [Shaw 03]. It is proposed that a digital elevation model (DEM) of the local surface, generated during traverse and without interaction from ground based operators, can be

  20. Electrofracturing test system and method of determining material characteristics of electrofractured material samples

    Science.gov (United States)

    Bauer, Stephen J.; Glover, Steven F.; Pfeifle, Tom; Su, Jiann-Cherng; Williamson, Kenneth Martin; Broome, Scott Thomas; Gardner, William Payton

    2017-08-01

    A device for electrofracturing a material sample and analyzing the material sample is disclosed. The device simulates an in situ electrofracturing environment so as to obtain electrofractured material characteristics representative of field applications while allowing permeability testing of the fractured sample under in situ conditions.

  1. Sensitivity, Specificity, and Positivity Predictors of the Pneumococcal Urinary Antigen Test in Community-Acquired Pneumonia.

    Science.gov (United States)

    Molinos, Luis; Zalacain, Rafael; Menéndez, Rosario; Reyes, Soledad; Capelastegui, Alberto; Cillóniz, Catia; Rajas, Olga; Borderías, Luis; Martín-Villasclaras, Juan J; Bello, Salvador; Alfageme, Inmaculada; Rodríguez de Castro, Felipe; Rello, Jordi; Ruiz-Manzano, Juan; Gabarrús, Albert; Musher, Daniel M; Torres, Antoni

    2015-10-01

    Detection of the C-polysaccharide of Streptococcus pneumoniae in urine by an immune-chromatographic test is increasingly used to evaluate patients with community-acquired pneumonia. We assessed the sensitivity and specificity of this test in the largest series of cases to date and used logistic regression models to determine predictors of positivity in patients hospitalized with community-acquired pneumonia. We performed a multicenter, prospective, observational study of 4,374 patients hospitalized with community-acquired pneumonia. The urinary antigen test was done in 3,874 cases. Pneumococcal infection was diagnosed in 916 cases (21%); 653 (71%) of these cases were diagnosed exclusively by the urinary antigen test. Sensitivity and specificity were 60 and 99.7%, respectively. Predictors of urinary antigen positivity were female sex; heart rate≥125 bpm, systolic blood pressureantibiotic treatment; pleuritic chest pain; chills; pleural effusion; and blood urea nitrogen≥30 mg/dl. With at least six of all these predictors present, the probability of positivity was 52%. With only one factor present, the probability was only 12%. The urinary antigen test is a method with good sensitivity and excellent specificity in diagnosing pneumococcal pneumonia, and its use greatly increased the recognition of community-acquired pneumonia due to S. pneumoniae. With a specificity of 99.7%, this test could be used to direct simplified antibiotic therapy, thereby avoiding excess costs and risk for bacterial resistance that result from broad-spectrum antibiotics. We also identified predictors of positivity that could increase suspicion for pneumococcal infection or avoid the unnecessary use of this test.

  2. Tests of gas sampling electromagnetic shower calorimeter

    International Nuclear Information System (INIS)

    Barbaro-Galtieri, A.; Carithers, W.; Day, C.; Johnson, K.J.; Wenzel, W.A.; Videau, H.

    1983-01-01

    An electromagnetic shower gas-sampling calorimeter has been tested in both Geiger and proportional discharge modes for incident electron energies in the range 0.125-16 GeV. The 0.2 radiation length-thick layers were lead-fiberglass laminates with cathode strips normal to the sense wires. The 5x10 mm 2 Geiger cells were formed with uniformly spaced nylon fibers perpendicular to the wires. Proportional mode measurements were carried out in the pressure range 1-10 atm. A Monte Carlo simulation is in good agreement with measured shower characteristics and has been used to predict the behavior for oblique of incidence and for various Geiger cell dimensions. (orig.)

  3. Testing predictive models of positive and negative affect with psychosocial, acculturation, and coping variables in a multiethnic undergraduate sample

    OpenAIRE

    Kuo, Ben CH; Kwantes, Catherine T

    2014-01-01

    Despite the prevalence and popularity of research on positive and negative affect within the field of psychology, there is currently little research on affect involving the examination of cultural variables and with participants of diverse cultural and ethnic backgrounds. To the authors’ knowledge, currently no empirical studies have comprehensively examined predictive models of positive and negative affect based specifically on multiple psychosocial, acculturation, and coping variables as pr...

  4. Comparison of three laboratorial tests for diagnosis of canine parvovirus infection

    Directory of Open Access Journals (Sweden)

    M.M.O. Silva

    2013-02-01

    Full Text Available The aim of this study was to evaluate the rapid tests currently used for canine parvovirus (CPV diagnosis: hemagglutination test (HA, enzyme immunoassay (EIA and polymerase chain reaction (PCR. A total of 112 fecal samples collected from diarrheic puppies up to one year of age were tested. The EIA was able to detect CPV antigen in 44 samples. By HA, 32 samples tested highly positive with titers >128, eight tested weakly positive (titers 32 and 64 and 72 were negative (titers <16. Using PCR, 57 samples were found positive including 13 EIA-negative and 19 HA-negative samples. The best correlation was observed between EIA and PCR (88.4%. These tests were able to detect all types of CPV, including CPV-2c. Considering that 23%-33% of dogs presenting enteritis did not show infection by EIA nor HA, negative results from the antigen detection tests should be confirmed through molecular methods.

  5. Can ultrasound of plantar plate have normal appearance with a positive drawer test?

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Eloy de Avila [Affiliated Professor, Department of Diagnostic Imaging, Escola Paulista de Medicina, Universidade Federal de São Paulo (EPM-Unifesp), São Paulo (Brazil); Mann, Tania Szejnfeld [Medical Assistant of Medicine and Surgery of the Foot and Ankle Group, Department of Orthopedics and Traumatology, EPM-Unifesp, São Paulo (Brazil); Puchnick, Andrea, E-mail: andrea.ddi@epm.br [Professor and Coordinator of Educational and Research Support, Department of Diagnostic Imaging, EPM-Unifesp, São Paulo (Brazil); Tertulino, Franklin de Freitas [Postgraduate Physician, Department of Diagnostic Imaging, EPM-Unifesp, São Paulo (Brazil); Cannato, Camila Testoni [Resident Physician, Department of Surgery, EPM-Unifesp, São Paulo (Brazil); Nery, Caio [Associate Professor, Department of Orthopedics and Traumatology, EPM-Unifesp, São Paulo (Brazil); Fernandes, Artur da Rocha Corrêa [Associate Professor, Department of Diagnostic Imaging, EPM-Unifesp, São Paulo (Brazil)

    2015-03-15

    Highlights: •We evaluate the accuracy of ultrasound to identify and measure the plantar plate. •We correlate ultrasound findings with those of physical examination and MRI. •Ultrasound and MRI measures of plantar plate were positively correlated. •Ultrasound is efficient in identifying and measuring plantar plate. •Ultrasound may complement physical examination. •Young asymptomatic subjects can present a grade I positive drawer test. -- Abstract: Objectives: The aims of this study were (1) to evaluate the reliability of ultrasound (US) examination in the identification and measurement of the metatarsophalangeal plantar plate (MTP-PP) in asymptomatic subjects and (2) to establish the correlation of US findings with those of physical examination and magnetic resonance imaging (MRI), once it is an important tool in the evaluation of the instability syndrome of the second and third rays. Materials and Methods: US examinations of the second and third MTP-PPs were performed in eight asymptomatic volunteers, totaling 32 MTP joints, by three examiners with different levels of experience in musculoskeletal US. Plantar plate dimensions, integrity and echogenicity, the presence of ruptures, and confidence level in terms of structure identification were determined using conventional US. Vascular flow was assessed using power Doppler. US data were correlated with data from physical examination and MRI. Results: MTP-PPs were ultrasonographically identified in 100% of cases, always showing homogeneous hyperechoic features and no detectable vascular flow on power Doppler, with 100% certainty in identification for all examiners. There was excellent US inter-observer agreement for longitudinal measures of second and third toe MTP-PPs and for transverse measures of the second toe MTP-PP. The MTP drawer test was positive for grade 1 MTP instability in 34.4% of joints with normal US results. Transverse MTP-PP measures were significantly higher in individuals with positive

  6. The Effect of Mock Tests on Iranian EFL learners’ Test Scores

    Directory of Open Access Journals (Sweden)

    Hossein Khodabakhshzadeh

    2016-07-01

    Full Text Available The effect of using tests in test preparation courses has been subject to debate. While some scholars such as Yang and Badger (2015 believe it is a cause of positive washback effect, others argue that this issue is tentative and context-bound (Green, 2007. Therefore, this study investigated the effect of using Mock tests in International English Language Testing System (IELTS preparation courses on students’ overall IELTS scores. Fifty one IELTS students were selected non-randomly through the quota sampling approach out of 76 students at Mahan Language Institute in Birjand, Iran.  These participants were distributed into Group 1 (n=25 and Group 2 (n=26. A complete IELTS test was administered to ensure that the Groups were homogeneous and to serve as pretest. After 10 sessions of intervention, a different IELTS test was administered as posttest. The results of between subject analysis through independent samples t-test revealed that using Mock tests in the IELTS preparation courses can positively affect the participants scores on IELTS exam. Pedagogical implications are discussed.

  7. A Psychometric Analysis of the Positive and Negative Affect Schedule for Children-Parent Version in a School Sample

    Science.gov (United States)

    Ebesutani, Chad; Okamura, Kelsie; Higa-McMillan, Charmaine; Chorpita, Bruce F.

    2011-01-01

    The current study was the 1st to examine the psychometric properties of the Positive and Negative Affect Schedule for Children-Parent Version (PANAS-C-P) using a large school-based sample of children and adolescents ages 8 to 18 (N = 606). Confirmatory factor analysis supported a 2-factor (correlated) model of positive affect (PA) and negative…

  8. Effect of microbiological testing on subsequent mid-infrared milk component analysis of the same milk sample.

    Science.gov (United States)

    Wojciechowski, Karen L; Melilli, Caterina; Barbano, David M

    2014-09-01

    Our objectives were to determine if mixing and sampling of a raw milk sample at 4°C for determination of total bacteria count (TBC) and if incubation at 14°C for 18h and sampling for a preliminary incubation (PI) count influenced the accuracy of subsequent fat, protein, or lactose measurement by mid-infrared (IR) analysis of milk from the same sample container due to either nonrepresentative sampling or the presence of microbial metabolites produced by microbial growth in the milk from the incubation. Milks of 4 fat levels (2.2, 3, 4, and 5%) reflected the range of fat levels encountered in producer milks. If the portion of milk removed from a cold sample was not representative, then the effect on a milk component test would likely be larger as fat content increases. Within the milks at each fat level, 3 treatments were used: (1) 20 vials of the same milk sampled for testing TBC using a BactoScan FC and then used for a milk component test; (2) 20 vials for testing TBC plus PI count followed by component test; and (3) 20 vials to run for IR component test without a prior micro sampling and testing. This was repeated in 3 different weeks using a different batch of milk each week. No large effect on the accuracy of component milk testing [IR fat B (carbon hydrogen stretch) and fat A (carbonyl stretch)] due to the cold milk sample handling and mixing procedures used for TBC was detected, confirming the fact that the physical removal of milk from the vial by the BactoScan FC (Foss Electric, Hillerød, Denmark) was a representative portion of the milk. However, the representativeness of any other sampling procedure (manual or automated) of a cold milk sample before running milk component testing on the same container of milk should be demonstrated and verified periodically as a matter of routine laboratory quality assurance. Running TBC with a BactoScan FC first and then IR milk analysis after had a minimal effect on milk component tests by IR when milk bacteria counts

  9. Advances in paper-based sample pretreatment for point-of-care testing.

    Science.gov (United States)

    Tang, Rui Hua; Yang, Hui; Choi, Jane Ru; Gong, Yan; Feng, Shang Sheng; Pingguan-Murphy, Belinda; Huang, Qing Sheng; Shi, Jun Ling; Mei, Qi Bing; Xu, Feng

    2017-06-01

    In recent years, paper-based point-of-care testing (POCT) has been widely used in medical diagnostics, food safety and environmental monitoring. However, a high-cost, time-consuming and equipment-dependent sample pretreatment technique is generally required for raw sample processing, which are impractical for low-resource and disease-endemic areas. Therefore, there is an escalating demand for a cost-effective, simple and portable pretreatment technique, to be coupled with the commonly used paper-based assay (e.g. lateral flow assay) in POCT. In this review, we focus on the importance of using paper as a platform for sample pretreatment. We firstly discuss the beneficial use of paper for sample pretreatment, including sample collection and storage, separation, extraction, and concentration. We highlight the working principle and fabrication of each sample pretreatment device, the existing challenges and the future perspectives for developing paper-based sample pretreatment technique.

  10. Use of Dried Capillary Blood Sampling for Islet Autoantibody Screening in Relatives: A Feasibility Study.

    Science.gov (United States)

    Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C

    2015-12-01

    Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.

  11. The evaluation of a rapid in situ HIV confirmation test in a programme with a high failure rate of the WHO HIV two-test diagnostic algorithm.

    Directory of Open Access Journals (Sweden)

    Derryck B Klarkowski

    Full Text Available BACKGROUND: Concerns about false-positive HIV results led to a review of testing procedures used in a Médecins Sans Frontières (MSF HIV programme in Bukavu, eastern Democratic Republic of Congo. In addition to the WHO HIV rapid diagnostic test algorithm (RDT (two positive RDTs alone for HIV diagnosis used in voluntary counselling and testing (VCT sites we evaluated in situ a practical field-based confirmation test against western blot WB. In addition, we aimed to determine the false-positive rate of the WHO two-test algorithm compared with our adapted protocol including confirmation testing, and whether weakly reactive compared with strongly reactive rapid test results were more likely to be false positives. METHODOLOGY/PRINCIPAL FINDINGS: 2864 clients presenting to MSF VCT centres in Bukavu during January to May 2006 were tested using Determine HIV-1/2 and UniGold HIV rapid tests in parallel by nurse counsellors. Plasma samples on 229 clients confirmed as double RDT positive by laboratory retesting were further tested using both WB and the Orgenics Immunocomb Combfirm HIV confirmation test (OIC-HIV. Of these, 24 samples were negative or indeterminate by WB representing a false-positive rate of the WHO two-test algorithm of 10.5% (95%CI 6.6-15.2. 17 of the 229 samples were weakly positive on rapid testing and all were negative or indeterminate by WB. The false-positive rate fell to 3.3% (95%CI 1.3-6.7 when only strong-positive rapid test results were considered. Agreement between OIC-HIV and WB was 99.1% (95%CI 96.9-99.9% with no false OIC-HIV positives if stringent criteria for positive OIC-HIV diagnoses were used. CONCLUSIONS: The WHO HIV two-test diagnostic algorithm produced an unacceptably high level of false-positive diagnoses in our setting, especially if results were weakly positive. The most probable causes of the false-positive results were serological cross-reactivity or non-specific immune reactivity. Our findings show that the OIC

  12. Acceptance Sampling Plans Based on Truncated Life Tests for Sushila Distribution

    Directory of Open Access Journals (Sweden)

    Amer Ibrahim Al-Omari

    2018-03-01

    Full Text Available An acceptance sampling plan problem based on truncated life tests when the lifetime following a Sushila distribution is considered in this paper. For various acceptance numbers, confidence levels and values of the ratio between fixed experiment time and particular mean lifetime, the minimum sample sizes required to ascertain a specified mean life were found. The operating characteristic function values of the suggested sampling plans and the producer’s risk are presented. Some tables are provided and the results are illustrated by an example of a real data set.

  13. Study of cross-reactivity in serum samples from dogs positive for Leishmania sp., Babesia canis and Ehrlichia canis in enzyme-linked immunosorbent assay and indirect fluorescent antibody test Estudo da reatividade cruzada em amostras de soro de cães positivos para Leishmania sp., Babesia canis e Ehrlichia canis, pelo ensaio imunoenzimático indireto e pela reação de imunofluorescência indireta

    Directory of Open Access Journals (Sweden)

    Trícia Maria F. de Sousa Oliveira

    2008-03-01

    Full Text Available To verify the presence of cross-reaction among leishmaniosis, ehrlichiosis and babesiosis in serological diagnostics used in human visceral leishmaniasis control programs, serum samples from leishmaniasis endemic and non-endemic areas were collected and tested by Indirect Fluorescent Antibody (IFAT and Enzyme-linked immunosorbent assay (ELISA. All serum samples from endemic areas were positive for Leishmania sp., by ELISA and IFAT, 51% positive for Babesia canis and 43% for Ehrlichia canis by IFAT. None of the serum samples from non-endemic areas were positive for Leishmania sp., by IFAT, but 67% were positive for B. canis and 78% for E. canis using the same test. When tested by ELISA for Leishmania sp., four samples from non-endemic area were positive. These dogs were then located and no clinical signs, parasites or antibody was detected in new tests for a six month period. Only one of these 4 samples was positive for B. canis by IFAT and ELISA and three for E. canis by IFAT. The results of the work suggest a co-infection in the endemic area and no serological cross-reaction among these parasites by IFAT and ELISA.Para verificar a existência de reação cruzada entre leishmaniose visceral, erliquiose e babesiose, nos testes sorológicos utilizados em programas de controle da leishmaniose visceral humana, amostras de soro canino provenientes de áreas endêmicas e não endêmicas para essa enfermidade, foram testadas pela Reação de Imunofluorescência (RIFI e Ensaio imunoenzimático (ELISA. Todos os soros provenientes de área endêmica foram positivos para Leishmania sp pelo ELISA e RIFI, 51% para Babesia canis e 43% para Ehrlichia canis pela RIFI. Pela RIFI, nenhum dos soros provenientes de área não endêmica foi positivo para Leishmania sp, sendo 67% positivos para B. canis e 78% para E. canis pelo mesmo teste. Quando testados pelo ELISA para Leishmania sp., quatro soros da área não endêmica foram positivos. Os cães foram localizados

  14. DWPF Sample Vial Insert Study-Statistical Analysis of DWPF Mock-Up Test Data

    Energy Technology Data Exchange (ETDEWEB)

    Harris, S.P. [Westinghouse Savannah River Company, AIKEN, SC (United States)

    1997-09-18

    This report is prepared as part of Technical/QA Task Plan WSRC-RP-97-351 which was issued in response to Technical Task Request HLW/DWPF/TTR-970132 submitted by DWPF. Presented in this report is a statistical analysis of DWPF Mock-up test data for evaluation of two new analytical methods which use insert samples from the existing HydragardTM sampler. The first is a new hydrofluoric acid based method called the Cold Chemical Method (Cold Chem) and the second is a modified fusion method.Either new DWPF analytical method could result in a two to three fold improvement in sample analysis time.Both new methods use the existing HydragardTM sampler to collect a smaller insert sample from the process sampling system. The insert testing methodology applies to the DWPF Slurry Mix Evaporator (SME) and the Melter Feed Tank (MFT) samples.The insert sample is named after the initial trials which placed the container inside the sample (peanut) vials. Samples in small 3 ml containers (Inserts) are analyzed by either the cold chemical method or a modified fusion method. The current analytical method uses a HydragardTM sample station to obtain nearly full 15 ml peanut vials. The samples are prepared by a multi-step process for Inductively Coupled Plasma (ICP) analysis by drying, vitrification, grinding and finally dissolution by either mixed acid or fusion. In contrast, the insert sample is placed directly in the dissolution vessel, thus eliminating the drying, vitrification and grinding operations for the Cold chem method. Although the modified fusion still requires drying and calcine conversion, the process is rapid due to the decreased sample size and that no vitrification step is required.A slurry feed simulant material was acquired from the TNX pilot facility from the test run designated as PX-7.The Mock-up test data were gathered on the basis of a statistical design presented in SRT-SCS-97004 (Rev. 0). Simulant PX-7 samples were taken in the DWPF Analytical Cell Mock

  15. Experimental study on pure titanium during the positive-torsion and positive-negative-torsion

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Han; Li, Fuguo, E-mail: fuguolx@nwpu.edu.cn; Li, Jinghui; Zhao, Zhen; Zhou, Shunshun; Wan, Qiong

    2016-09-30

    The results of the mechanical properties, microstructure and fracture analysis of the pure titanium deformed by positive-torsion (PT) and positive-negative-torsion (PNT) are investigated by uniaxial tensile (UT) test, micro-indentation (MI) test, optical microscope (OM), transmission electron microscope (TEM) and scanning electron microscope (SEM). The UT test indicates that the strength increases obviously with the increase of torsion radian during PT. However, the strength firstly increases quickly, and then tends to steady with the increase of deformation during PNT. The similar phenomena are also shown through MI hardness analysis. The results from geometrically necessary dislocations (GNDs) and statistically stored dislocations (SSDs) indicate that the dislocation density varies differently with the increase of deformation during PT and PNT. OM observation shows the grains are elongated and large numbers of deformation twins are observed during PT while the equiaxial grains are always presented during PNT. The variations of dislocation density during PT and PNT are verified by TEM. Besides, quantities of subgrains (SGs) are observed owing to the accumulated larger plastic strain during PNT while large numbers of deformation twins intersect with each other during PT. The fracture analysis indicates that large numbers of micro-voids distribute non-uniformly on fracture surface of sample twisted by PNT. However, the characteristics of ductile and brittle fracture are observed on fracture surface of sample twisted by PT.

  16. Sample-taking apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Tanov, Y I; Ismailov, R A; Orazov, A

    1980-10-07

    The invention refers to the equipment for testing water-bearing levels in loose rocks. Its purpose is to simultaneously remove with the rock sample a separate fluid sample from the assigned interval. The sample-taking apparatus contains a core lifter which can be submerged into the casting string with housing and front endpiece in the form of a rod with a piston which covers the cavity of the core lifter, as well as mechanism for fixing and moving the endpiece within the core lifter cavity. The device differs from the known similar devices because the upper part of the housing of the core lifter is equipped with a filter and mobile casting which covers the filter. In this case the casing is connected to the endpiece rod and the endpiece is installed with the possibility of movement which is limited with fixing in the upper position and in the extreme upper position it divides the core lifter cavity into two parts, filter settling tank and core-receiving cavity.

  17. Development of a superconducting position sensor for the Satellite Test of the Equivalence Principle

    Science.gov (United States)

    Clavier, Odile Helene

    The Satellite Test of the Equivalence Principle (STEP) is a joint NASA/ESA mission that proposes to measure the differential acceleration of two cylindrical test masses orbiting the earth in a drag-free satellite to a precision of 10-18 g. Such an experiment would conceptually reproduce Galileo's tower of Pisa experiment with a much longer time of fall and greatly reduced disturbances. The superconducting test masses are constrained in all degrees of freedom except their axial direction (the sensitive axis) using superconducting bearings. The STEP accelerometer measures the differential position of the masses in their sensitive direction using superconducting inductive pickup coils coupled to an extremely sensitive magnetometer called a DC-SQUID (Superconducting Quantum Interference Device). Position sensor development involves the design, manufacture and calibration of pickup coils that will meet the acceleration sensitivity requirement. Acceleration sensitivity depends on both the displacement sensitivity and stiffness of the position sensor. The stiffness must kept small while maintaining stability of the accelerometer. Using a model for the inductance of the pickup coils versus displacement of the test masses, a computer simulation calculates the sensitivity and stiffness of the accelerometer in its axial direction. This simulation produced a design of pickup coils for the four STEP accelerometers. Manufacture of the pickup coils involves standard photolithography techniques modified for superconducting thin-films. A single-turn pickup coil was manufactured and produced a successful superconducting coil using thin-film Niobium. A low-temperature apparatus was developed with a precision position sensor to measure the displacement of a superconducting plate (acting as a mock test mass) facing the coil. The position sensor was designed to detect five degrees of freedom so that coupling could be taken into account when measuring the translation of the plate

  18. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  19. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  20. Principles of Work Sample Testing. 1. A Non-Empirical Taxonomy of Test Uses

    Science.gov (United States)

    1979-04-01

    UNIVERSITY % ’ Bowling Green , Ohio 43403 e April 1979 Contract DAHC 19-77-C-0007 Cj Prepared for U.S. ARMY RESEARCH INSTITUTEfor the BEHAVIORAL and...inferring changes in enotionality, and GSR is said to be a measure of emotion . Much of psychological measurement is derived measurement, but it is...ARI TECHNICAL REPORT TR-79-A8 Principles of Work Sample Testingi I. A Non-Empirical Taxonomy of Test Uses b y Robert M. Guion BOWLING GREEN STATE

  1. Results from tests of TFL Hydragard sampling loop

    International Nuclear Information System (INIS)

    Steimke, J.L.

    1995-03-01

    When the Defense Waste Processing Facility (DWPF) is operational, processed radioactive sludge will be transferred in batches to the Slurry Mix Evaporator (SME), where glass frit will be added and the contents concentrated by boiling. Batches of the slurry mixture are transferred from the SME to the Melter Feed Tank (MFT). Hydragard reg-sign sampling systems are used on the SME and the MFT for collecting slurry samples in vials for chemical analysis. An accurate replica of the Hydragard sampling system was built and tested in the thermal Fluids Laboratory (TFL) to determine the hydragard accuracy. It was determined that the original Hydragard valve frequently drew a non-representative sample stream through the sample vial that ranged from frit enriched to frit depleted. The Hydragard valve was modified by moving the plunger and its seat backwards so that the outer surface of the plunger was flush with the inside diameter of the transfer line when the valve was open. The slurry flowing through the vial accurately represented the composition of the slurry in the reservoir for two types of slurries, different dilution factors, a range of transfer flows and a range of vial flows. It was then found that the 15 ml of slurry left in the vial when the Hydragard valve was closed, which is what will be analyzed at DWPF, had a lower ratio of frit to sludge as characterized by the lithium to iron ratio than the slurry flowing through it. The reason for these differences is not understood at this time but it is recommended that additional experimentation be performed with the TFL Hydragard loop to determine the cause

  2. Performances on five verbal fluency tests in a healthy, elderly Danish sample

    DEFF Research Database (Denmark)

    Stokholm, Jette; Jørgensen, Kasper; Vogel, Asmus

    2013-01-01

    Verbal fluency tests are widely used as measures of language and executive functions. This study presents data for five tests; semantic fluency (animals, supermarket items and alternating between cities and professions), lexical fluency (s-words), and action fluency (verbs) based on a sample of 100...

  3. Monitoring the electron beam position at the TESLA test facility free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Kamps, T

    2000-06-14

    The operation of a free electron laser working in the Self Amplified Spontaneous Emission mode (SASE FEL) requires the electron trajectory to be aligned with very high precision in overlap with the photon beam. In order to ensure this overlap, one module of the SASE FEL undulator at the TESLA Test Facility (TTF) is equipped with a new type of waveguide beam position monitor (BPM). Four waveguides are arranged symmetrically around the beam pipe, each channel couples through a small slot to the electromagnetic beam field. The induced signal depends on the beam intensity and on the transverse beam position in terms of beam-to-slot distance. With four slot--waveguide combinations a linear position sensitive signal can be achieved, which is independent of the beam intensity. The signals transduced by the slots are transferred by ridged waveguides through an impedance matching stage into a narrowband receiver tuned to 12 GHz. The present thesis describes design, tests, and implementation of this new type of BPM. (orig.)

  4. Phytotoxkit® and Ostracodtoxkit® tests for assessing the toxicity of sediment samples with high concentration of heavy metals

    Science.gov (United States)

    Garcia-Lorenzo, Maria Luz; Martinez-Sanchez, Maria Jose; Molina, Jose; Hernandez-Cordoba, Manuel

    2010-05-01

    . As regards the phytotoxicity test, an influence on seed germination was observed. Correlation analysis between heavy metal concentration, soil characteristics and plant test results showed that growth inhibition in the plant species was negatively correlated with pH and calcium carbonate content and was positively correlated with Eh, EC and total arsenic content in soil samples. All three species chosen for this assay showed greater sensitivity to Cd than As and Pb (in that order). Correlation analysis showed that the mortality of ostracods was positively correlated with Eh and EC and negatively correlated with pH and calcium carbonate content. As in the case of plants, the sensitivity of ostracods was greatest for Cd, followed by As and Pb.

  5. Report of testing and sampling of municipal supply well PM-4

    International Nuclear Information System (INIS)

    Koch, Richard J.; Longmire, Patrick; Rogers, David B.; Mullen, Ken

    1999-01-01

    During drilling of regional aquifer characterization borehole R-25, located in the western part of Los Alamos National Laboratory (LANL) at Technical Area (TA) 16, groundwater samples were collected from perched zones of saturation and the regional aquifer that contained elevated levels of high explosive (HE) compounds. One of the nearest Los Alamos County municipal supply wells potentially located down gradient from borehole R-25 is PM-4, located on Mesita del Buey at the west end of TA-54. During the winter of 1998 and 1999 the pump in PM-4 had been removed from the well for scheduled maintenance by the Los Alamos County Public Utilities Department (PUD). Because the pump was removed from PM-4, the opportunity existed to enter the well to (1) perform tests to determine where within the regional aquifer groundwater entered the well and (2) collect groundwater samples from the producing zones for analyses to determine if HE contaminants were present in discrete zones within the regional aquifer. The report of the activities that were performed during March 1999 for the testing and sampling of municipal supply well PM-4 is provided. The report provides a description of the field activities associated with the two phases of the project, including (1) the results of the static and dynamic spinner log surveys, and (2) a description of the sampling activities and the field-measured groundwater quality parameters that were obtained during sampling activities. This report also provides the analytical results of the groundwater samples and a brief discussion of the results of the project

  6. [Blood Test Patterns for Blood Donors after Nucleic Acid Detection in the Blood Center].

    Science.gov (United States)

    Men, Shou-Shan; Lv, Lian-Zhi; Chen, Yuan-Feng; Han, Chun-Hua; Liu, Hong-Yu; Yan, Yan

    2017-12-01

    To investigate the blood test patterns for blood donors after nucleic acid detection in blood center. The collected blood samples after voluntary blood donors first were detected by conventional ELISA, then 31981 negative samples were detected via HBV/HCV/HIV combined nucleic acid test of 6 mixed samples(22716 cases) or single samples(9265 cases) by means of Roche cobas s201 instrument. The combined detection method as follows: the blood samples were assayed by conventional nucleic acid test of 6 mixed samples, at same time, 6 mixed samples were treated with polyethylene glycol precipitation method to concentrate the virus, then the nucleic acid test of blood samples was performed; the single detection method as follows: firstly the conventional nucleic acid test of single sample was performed, then the positive reactive samples after re-examination were 6-fold diluted to simulate the nucleic acid test of 6-mixed samples. The positive rate of positive samples detected by combined nucleic acid test, positive samples detected by nucleic acid test of mixed virus concentration and positive samples detected by single nucleic acid test was statistically analyzed. In addition, for HBV + persons the serological test yet should be performed. In 22 716 samples detected by nucleic acid test of 6 mixed samples (MP-6-NAT) , 9 cases were HBV + (0.40‰, 9/22716); at same time, the detection of same samples by nucleic acid test of mixed sample virus concentration showed 29 cases of HBV + (1.28‰, 29/22716). In 9265 samples detected by single nucleic acid test(ID-NAT) 12 cases showed HBV + (1.30‰, 12/9265), meanwhile the detection of these 12 samples with HBV + by 6-fold dilution for virus concentration found only 4 samples with HBV + . In serological qualified samples, ID-NAT unqualified rate was 1.28‰, which was higher than that of MP-6-NAT(0.4‰) (χ 2 =8.11, P0.05). In 41 samples with HBsAg - HBV DNA + detected by ELISA, 36 samples were confirmed to be occult HBV

  7. Sample damage investigation by laboratory testing and DDM modelling by FRACOD2D of Brazilian tests on Toki granite

    International Nuclear Information System (INIS)

    Lanaro, Flavio; Sato, Toshinori; Funato, Akio

    2008-01-01

    Numerical scooping calculations by means of FRACOD 2D had shown that Brazilian test models present a bend in the relation between the sample deformation perpendicularly to the loading direction and the load itself. The input 'direct' tensile strength of the rock could be re-obtained based on the numerical load at the bend. In this study, a similar technique is applied to specially designed Brazilian tests on Toki granite (Gifu, Japan) which also exhibits such bend for a tensile stress in the centre of the samples of about 2.6 MPa. However, the samples show a wide range of Brazilian tensile strengths that appear to be negatively correlated to the level of in-situ stress at the depth where the samples were taken. The correlation was interpreted as an effect of sample damage due to drilling in a stressed rock mass. Numerical models were designed with various preexist ent crack patterns to simulate the sample damage. The numerical results show Brazilian peak strength results ranging between 6.7 and 13.0 MPa, which are very realistic considering that the laboratory Brazilian tensile strength was observed to vary between 4.1 and 11.3 MPa. These values are all larger than the stress at the bend which is then interpreted as the tensile strength of the weakest grains in the granite. It is also shown that the occurrence of newly initiated cracks at the bend completely changes the stress distribution and failure mechanism of the samples: this explains why the Brazilian tensile strength should be higher than the 'direct' tensile strength of the rock from uniaxial tests. (author)

  8. Clinical experience of laboratory follow-up with noninvasive prenatal testing using cell-free DNA and positive microdeletion results in 349 cases.

    Science.gov (United States)

    Schwartz, S; Kohan, M; Pasion, R; Papenhausen, P R; Platt, L D

    2018-02-01

    Screening via noninvasive prenatal testing (NIPT) involving the analysis of cell-free DNA (cfDNA) from plasma has become readily available to screen for chromosomal and DNA aberrations through maternal blood. This report reviews a laboratory's experience with follow-up of positive NIPT screens for microdeletions. Patients that were screened positive by NIPT for a microdeletion involving 1p, 4p, 5p, 15q, or 22q who underwent diagnostic studies by either chorionic villus sampling or amniocentesis were evaluated. The overall positive predictive value for 349 patients was 9.2%. When a microdeletion was confirmed, 39.3% of the cases had additional abnormal microarray findings. Unrelated abnormal microarray findings were detected in 11.8% of the patients in whom the screen positive microdeletion was not confirmed. Stretches of homozygosity in the microdeletion were frequently associated with a false positive cfDNA microdeletion result. Overall, this report reveals that while cfDNA analysis will screen for microdeletions, the positive predictive value is low; in our series it is 9.2%. Therefore, the patient should be counseled accordingly. Confirmatory diagnostic microarray studies are imperative because of the high percentage of false positives and the frequent additional abnormalities not delineated by cfDNA analysis. © 2018 John Wiley & Sons, Ltd.

  9. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  10. Detecting positive quadrant dependence and positive function dependence

    NARCIS (Netherlands)

    Janic-Wróblewska, A.; Kallenberg, W.C.M.; Ledwina, T.

    2004-01-01

    There is a lot of interest in positive dependence going beyond linear correlation. In this paper three new rank tests for testing independence against positive dependence are introduced. The first one is directed on positive quadrant dependence, the second and third one concentrate on positive

  11. Detecting positive quadrant dependence and positive function dependence

    NARCIS (Netherlands)

    Janic-Wróblewska, A.; Kallenberg, W.C.M.; Ledwina, T.

    2003-01-01

    There is a lot of interest in positive dependence going beyond linear correlation. In this paper three new rank tests for testing independence against positive dependence are introduced. The first one is directed on positive quadrant dependence, the second and third one concentrate on positive

  12. Mapping cell populations in flow cytometry data for cross‐sample comparison using the Friedman–Rafsky test statistic as a distance measure

    Science.gov (United States)

    Hsiao, Chiaowen; Liu, Mengya; Stanton, Rick; McGee, Monnie; Qian, Yu

    2015-01-01

    Abstract Flow cytometry (FCM) is a fluorescence‐based single‐cell experimental technology that is routinely applied in biomedical research for identifying cellular biomarkers of normal physiological responses and abnormal disease states. While many computational methods have been developed that focus on identifying cell populations in individual FCM samples, very few have addressed how the identified cell populations can be matched across samples for comparative analysis. This article presents FlowMap‐FR, a novel method for cell population mapping across FCM samples. FlowMap‐FR is based on the Friedman–Rafsky nonparametric test statistic (FR statistic), which quantifies the equivalence of multivariate distributions. As applied to FCM data by FlowMap‐FR, the FR statistic objectively quantifies the similarity between cell populations based on the shapes, sizes, and positions of fluorescence data distributions in the multidimensional feature space. To test and evaluate the performance of FlowMap‐FR, we simulated the kinds of biological and technical sample variations that are commonly observed in FCM data. The results show that FlowMap‐FR is able to effectively identify equivalent cell populations between samples under scenarios of proportion differences and modest position shifts. As a statistical test, FlowMap‐FR can be used to determine whether the expression of a cellular marker is statistically different between two cell populations, suggesting candidates for new cellular phenotypes by providing an objective statistical measure. In addition, FlowMap‐FR can indicate situations in which inappropriate splitting or merging of cell populations has occurred during gating procedures. We compared the FR statistic with the symmetric version of Kullback–Leibler divergence measure used in a previous population matching method with both simulated and real data. The FR statistic outperforms the symmetric version of KL‐distance in distinguishing

  13. Mapping cell populations in flow cytometry data for cross-sample comparison using the Friedman-Rafsky test statistic as a distance measure.

    Science.gov (United States)

    Hsiao, Chiaowen; Liu, Mengya; Stanton, Rick; McGee, Monnie; Qian, Yu; Scheuermann, Richard H

    2016-01-01

    Flow cytometry (FCM) is a fluorescence-based single-cell experimental technology that is routinely applied in biomedical research for identifying cellular biomarkers of normal physiological responses and abnormal disease states. While many computational methods have been developed that focus on identifying cell populations in individual FCM samples, very few have addressed how the identified cell populations can be matched across samples for comparative analysis. This article presents FlowMap-FR, a novel method for cell population mapping across FCM samples. FlowMap-FR is based on the Friedman-Rafsky nonparametric test statistic (FR statistic), which quantifies the equivalence of multivariate distributions. As applied to FCM data by FlowMap-FR, the FR statistic objectively quantifies the similarity between cell populations based on the shapes, sizes, and positions of fluorescence data distributions in the multidimensional feature space. To test and evaluate the performance of FlowMap-FR, we simulated the kinds of biological and technical sample variations that are commonly observed in FCM data. The results show that FlowMap-FR is able to effectively identify equivalent cell populations between samples under scenarios of proportion differences and modest position shifts. As a statistical test, FlowMap-FR can be used to determine whether the expression of a cellular marker is statistically different between two cell populations, suggesting candidates for new cellular phenotypes by providing an objective statistical measure. In addition, FlowMap-FR can indicate situations in which inappropriate splitting or merging of cell populations has occurred during gating procedures. We compared the FR statistic with the symmetric version of Kullback-Leibler divergence measure used in a previous population matching method with both simulated and real data. The FR statistic outperforms the symmetric version of KL-distance in distinguishing equivalent from nonequivalent cell

  14. A GMM-Based Test for Normal Disturbances of the Heckman Sample Selection Model

    Directory of Open Access Journals (Sweden)

    Michael Pfaffermayr

    2014-10-01

    Full Text Available The Heckman sample selection model relies on the assumption of normal and homoskedastic disturbances. However, before considering more general, alternative semiparametric models that do not need the normality assumption, it seems useful to test this assumption. Following Meijer and Wansbeek (2007, the present contribution derives a GMM-based pseudo-score LM test on whether the third and fourth moments of the disturbances of the outcome equation of the Heckman model conform to those implied by the truncated normal distribution. The test is easy to calculate and in Monte Carlo simulations it shows good performance for sample sizes of 1000 or larger.

  15. Quantitative determination of minerals in Nevada Test Site samples by x-ray diffraction

    International Nuclear Information System (INIS)

    Pawloski, G.A.

    1983-07-01

    The external standard intensity ratio technique has been developed into a routine procedure for quantitatively determining mineralogic compositions of Nevada Test Site (NTS) samples by x-ray diffraction. This technique used ratios of x-ray intensity peaks from the same run which eliminates many possible errors. Constants have been determined for each of thirteen minerals commonly found in NTS samples - quartz, montmorillonite, illite, clinoptilolite, cristobalite, feldspars, calcite, dolomite, hornblende, kaolinite, muscovite, biotite, and amorphous glass. Ratios of the highest intensity peak of each mineral to be quantified in the sample and the highest intensity peak of quartz are used to calculate sample composition. The technique has been tested on samples with three to eleven components representative of geologic environments at NTS, and is accurate to 7.0 wt % of the total sample. The minimum amount of each of these minerals detectable by x-ray diffraction has also been determined. QUANTS is a computer code that calculates mineral contents and produces a report sheet. Constants for minerals in NTS samples other than those listed above can easily be determined, and added to QUANTS at any time

  16. Position-specific 13C distributions within propane from experiments and natural gas samples

    Science.gov (United States)

    Piasecki, Alison; Sessions, Alex L.; Lawson, Michael; Ferreira, A.A.; Santos Neto, E. V.; Ellis, Geoffrey S.; Lewan, Michael; Eilers, J.M.

    2018-01-01

    Site-specific carbon isotope measurements of organic compounds potentially recover information that is lost in a conventional, ‘bulk’ isotopic analysis. Such measurements are useful because isotopically fractionating processes may have distinct effects at different molecular sites, and thermodynamically equilibrated populations of molecules tend to concentrate heavy isotopes in one molecular site versus another. Most recent studies of site-specific 13C in organics use specialized Nuclear Magnetic Resonance (NMR) techniques or complex chemical degradations prior to mass spectrometric measurements. Herein we present the first application of a new mass spectrometric technique that reconstructs the site-specific carbon isotope composition of propane based on measurements of the 13C/12C ratios of two or more fragment ions that sample different proportions of the terminal and central carbon sites. We apply this method to propane from laboratory experiments and natural gas samples to explore the relationships between site-specific carbon isotope composition, full-molecular δ13C, thermal maturity, and variation in organic matter precursors. Our goal is to advance the understanding of the sources and histories of short-chain alkanes within geologic systems. Our findings suggest that propane varies in its site-specific carbon isotope structure, which is correlated with increasing thermal maturity, first increasing in terminal position δ13C and then increasing in both center and terminal position δ13C. This pattern is observed in both experimental and natural samples, and is plausibly explained by a combination of site-specific, temperature-dependent isotope effects associated with conversion of different precursor molecules (kerogen, bitumen, and/or oil) to propane, differences in site-specific isotopic contents of those precursors, and possibly distillation of reactive components of those precursors with increasing maturity. We hypothesize that the largest changes in

  17. Position-specific 13C distributions within propane from experiments and natural gas samples

    Science.gov (United States)

    Piasecki, Alison; Sessions, Alex; Lawson, Michael; Ferreira, A. A.; Santos Neto, E. V.; Ellis, Geoffrey S.; Lewan, Michael D.; Eiler, John M.

    2018-01-01

    Site-specific carbon isotope measurements of organic compounds potentially recover information that is lost in a conventional, 'bulk' isotopic analysis. Such measurements are useful because isotopically fractionating processes may have distinct effects at different molecular sites, and thermodynamically equilibrated populations of molecules tend to concentrate heavy isotopes in one molecular site versus another. Most recent studies of site-specific 13C in organics use specialized Nuclear Magnetic Resonance (NMR) techniques or complex chemical degradations prior to mass spectrometric measurements. Herein we present the first application of a new mass spectrometric technique that reconstructs the site-specific carbon isotope composition of propane based on measurements of the 13C/12C ratios of two or more fragment ions that sample different proportions of the terminal and central carbon sites. We apply this method to propane from laboratory experiments and natural gas samples to explore the relationships between site-specific carbon isotope composition, full-molecular δ13C, thermal maturity, and variation in organic matter precursors. Our goal is to advance the understanding of the sources and histories of short-chain alkanes within geologic systems. Our findings suggest that propane varies in its site-specific carbon isotope structure, which is correlated with increasing thermal maturity, first increasing in terminal position δ13C and then increasing in both center and terminal position δ13C. This pattern is observed in both experimental and natural samples, and is plausibly explained by a combination of site-specific, temperature-dependent isotope effects associated with conversion of different precursor molecules (kerogen, bitumen, and/or oil) to propane, differences in site-specific isotopic contents of those precursors, and possibly distillation of reactive components of those precursors with increasing maturity. We hypothesize that the largest changes in

  18. Physiologic performance test differences in female volleyball athletes by competition level and player position.

    Science.gov (United States)

    Schaal, Monique; Ransdell, Lynda B; Simonson, Shawn R; Gao, Yong

    2013-07-01

    The purpose of this study was to examine physiologic performance test differences by competition level (high school and Division-I collegiate athletes) and player position (hitter, setter, defensive specialist) in 4 volleyball-related tests. A secondary purpose was to establish whether a 150-yd shuttle could be used as a field test to assess anaerobic capacity. Female participants from 4 varsity high school volleyball teams (n = 27) and 2 Division-I collegiate volleyball teams (n = 26) were recruited for the study. Participants completed 4 performance-based field tests (vertical jump, agility T-test, and 150- and 300-yd shuttle runs) after completing a standardized dynamic warm-up. A 2-way multivariate analysis of variance with Bonferroni post hoc adjustments (when appropriate) and effect sizes were used for the analyses. The most important findings of this study were that (a) college volleyball athletes were older, heavier, and taller than high school athletes; (b) high school athletes had performance deficiencies in vertical jump/lower-body power, agility, and anaerobic fitness; (c) lower-body power was the only statistically significant difference in the performance test measures by player position; and (d) the correlation between the 150- and 300-yd shuttle was moderate (r = 0.488). Female high school volleyball players may enhance their ability to play collegiate volleyball by improving their vertical jump, lower-body power, agility, and anaerobic fitness. Furthermore, all player positions should emphasize lower-body power conditioning. These physical test scores provide baseline performance scores that should help strength and conditioning coaches create programs that will address deficits in female volleyball player performance, especially as they transition from high school to college.

  19. Operability test procedure for the Rotary Mode Core Sampling System Exhausters 3 and 4

    International Nuclear Information System (INIS)

    WSaldo, E.J.

    1995-01-01

    This document provides a procedure for performing operability testing of the Rotary Mode Core Sampling System Exhausters 3 ampersand 4. Upon completion of testing activities an operability testing report will be issued

  20. Summary of Test Results for Daya Bay Rock Samples

    International Nuclear Information System (INIS)

    Onishi, Celia Tiemi; Dobson, Patrick; Nakagawa, Seiji

    2004-01-01

    A series of analytical tests was conducted on a suite of granitic rock samples from the Daya Bay region of southeast China. The objective of these analyses was to determine key rock properties that would affect the suitability of this location for the siting of a neutrino oscillation experiment. This report contains the results of chemical analyses, rock property measurements, and a calculation of the mean atomic weight

  1. Clinical evaluation of human papillomavirus detection by careHPV™ test on physician-samples and self-samples using the indicating FTA Elute® card.

    Science.gov (United States)

    Wang, Shao-Ming; Hu, Shang-Ying; Chen, Feng; Chen, Wen; Zhao, Fang-Hui; Zhang, Yu-Qing; Ma, Xin-Ming; Qiao, You-Lin

    2014-01-01

    To make the clinical evaluation of a solid-state human papillomavirus (HPV) sampling medium in combination with an economical HPV testing method (careHPV™) for cervical cancer screening. 396 women aged 25-65 years were enrolled for cervical cancer screening, and four samples were collected. Two samples were collected by woman themselves, among which one was stored in DCM preservative solution (called "liquid sample") and the other was applied on the Whatman Indicating FTA Elute® card (FTA card). Another two samples were collected by physician and stored in DCM preservative solution and FTA card, respectively. All the samples were detected by careHPV™ test. All the women were administered a colposcopy examination, and biopsies were taken for pathological confirmation if necessary. FTA card demonstrated a comparable sensitivity of detecting high grade Cervical Intraepithelial Neoplasia (CIN) with the liquid sample carrier for self and physician-sampling, but showed a higher specificity than that of liquid sample carrier for self-sampling (FTA vs Liquid: 79.0% vs 71.6%, p=0.02). Generally, the FTA card had a comparable accuracy with that of Liquid-based medium by different sampling operators, with an area under the curve of 0.807 for physician and FTA, 0.781 for physician and Liquid, 0.728 for self and FTA, and 0.733 for self and Liquid (p>0.05). FTA card is a promising sample carrier for cervical cancer screening. With appropriate education programmes and further optimization of the experimental workflow, FTA card based self-collection in combination with centralized careHPV™ testing can help expand the coverage of cervical cancer screening in low-resource areas.

  2. Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

    Science.gov (United States)

    Chinn, Tori N.; Lee, Anthony K.; Boone, Travis D.; Tan, Ming X.; Chin, Matthew M.; McCutcheon, Griffin C.; Horne, Mera F.; Padgen, Michael R.; Blaich, Justin T.; Forgione, Joshua B.; hide

    2017-01-01

    We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo

  3. Initial testing of a Compact Crystal Positioning System for the TOPAZ Single-Crystal Diffractometer at the Spallation Neutron Source

    International Nuclear Information System (INIS)

    Frost, Matthew J.; Austin, Michael D.; Viola, Robert; Thomison, Jack; Carmen, Peter; Hoffmann, Christina; Miller, Echo M.; Mosier, Lisa B.; Overbay, Mark A.

    2009-01-01

    A precise, versatile, and automated method of orienting a sub-millimeter crystal in a focused neutron beam is required for e cient operation of the TOPAZ Single Crystal Di ractometer at the Spallation Neutron Source at Oak Ridge National Laboratory. To ful ll this need, a Compact Crystal Positioning System (CCPS) has been developed in collaboration with Square One Systems Design in Jackson, Wyoming. The system incorporates a tripod design with six vacuum-compatible piezoelectric linear motors capable of < 1 m resolution. National Instruments LabVIEW provides a means of system automation while at the same time accommodating the modular nature of the SNS sample environment control software for straightforward system integration. Initial results in a cryogenic test environment will be presented, as well as results from ambient tests performed at the Advanced Photon Source at Argonne National Laboratory.

  4. 46 CFR 160.010-7 - Methods of sampling, inspections and tests.

    Science.gov (United States)

    2010-10-01

    ... laboratory must inspect the place of manufacture, observe the various operations involved in the construction... section. (g) Painter attachment strength test. The apparatus must be positioned with its painter attachment fitting at the lowest point of the apparatus, directly below the center of buoyancy. The apparatus...

  5. A Note on Confidence Interval for the Power of the One Sample Test

    OpenAIRE

    A. Wong

    2010-01-01

    In introductory statistics texts, the power of the test of a one-sample mean when the variance is known is widely discussed. However, when the variance is unknown, the power of the Student's -test is seldom mentioned. In this note, a general methodology for obtaining inference concerning a scalar parameter of interest of any exponential family model is proposed. The method is then applied to the one-sample mean problem with unknown variance to obtain a ( 1 − ) 100% confidence interval for...

  6. Testing an Impedance Non-destructive Method to Evaluate Steel-Fiber Concrete Samples

    Science.gov (United States)

    Komarkova, Tereza; Fiala, Pavel; Steinbauer, Miloslav; Roubal, Zdenek

    2018-02-01

    Steel-fiber reinforced concrete is a composite material characterized by outstanding tensile properties and resistance to the development of cracks. The concrete, however, exhibits such characteristics only on the condition that the steel fibers in the final, hardened composite have been distributed evenly. The current methods to evaluate the distribution and concentration of a fiber composite are either destructive or exhibit a limited capability of evaluating the concentration and orientation of the fibers. In this context, the paper discusses tests related to the evaluation of the density and orientation of fibers in a composite material. Compared to the approaches used to date, the proposed technique is based on the evaluation of the electrical impedance Z in the band close to the resonance of the sensor-sample configuration. Using analytically expressed equations, we can evaluate the monitored part of the composite and its density at various depths of the tested sample. The method employs test blocks of composites, utilizing the resonance of the measuring device and the measured sample set; the desired state occurs within the interval of between f=3 kHz and 400 kHz.

  7. Beam test of the 2D position sensitive neutron detector

    International Nuclear Information System (INIS)

    Tian Lichao; Chen Yuanbo; Sun Zhijia; Tang Bin; Zhou Jianrong; Qi Huirong; Liu Rongguang; Zhang Jian; Yang Guian; Xu Hong

    2014-01-01

    China Spallation Neutron Source (CSNS), one of the Major scientific apparatuses of the national Eleventh Five-Year Plane, is under construction and three spectrumeters will be constructed in the first phase of the project. A 2D position sensitive neutron detector has been constructed for the Multifunctional Reflect spectrumeter (MR) in Institute of High Energy Physics (IHEP). The basic operation principle of the detector and the test on the residual stress diffractometer of Chinese Advanced Research Reactor (CARR) in China Institute of Atomic Energy (CIAE) is introduced in this paper. The results show that it has a good position resolution of l.18 mm (FWHM) for the neutrons of l.37 A and 2D imaging ability, which is consistent with the theory. It can satisfy the requirements of MR and lays the foundation for the construction of larger neutron detectors. (authors)

  8. Effectiveness of the Positioning Statement: Experimental Test on Brand Awareness in Competitive Contexts

    Directory of Open Access Journals (Sweden)

    Rafael Barreiros Porto

    2018-03-01

    Full Text Available Good positioning statements have an effect on consumer brand awareness. However, the competitive context formed by the novelty of the category and the brand market structure may hinder the assimilation of positioning and its association with the pre-existing image. This study assesses the effectiveness of positioning statements in the generation of brand awareness, considering its competitive context. Using an experimental design, with a group of control, the exposure of brands and their competitive contexts were manipulated and the positioning statement remained constant for a sample of consumers. The results show the positioning statement had an effect on both assimilation of the message and valence of image association, which adds awareness for the brand, but only for the traditional category. The effectiveness on the message assimilation occurred within the weak brand and within the less known median brand. For the image valence, it occurred only between the weak brand and the strong one from the traditional category. These findings are distinct among consumer segments. The research brings up a classic theme, but presents a new methodological approach to measure the effectiveness of brand positioning.

  9. Opportunities and challenges when pooling milk samples using ELISA

    DEFF Research Database (Denmark)

    Græsbøll, Kaare; Andresen, Lars Ole; Hisham Beshara Halasa, Tariq

    2017-01-01

    -positive samples by pooling. To illustrate this, the sensitivity of antibody ELISA on pooled samples of bovine milk for Salmonella Dublin, Mycobacterium avium spp. paratuberculosis, and bovine virus diarrhea was tested. For these milk assays, the analytical sensitivity decreased rapidly with increasing pool sizes...

  10. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  11. The effect of blood sample positions in a water phantom at the time of irradiation on the dicentric yield

    International Nuclear Information System (INIS)

    Inoue, Yoshinori

    1995-01-01

    Blood samples of man and rabbit, placed at various distances from the surface of a water phantom with a dosimeter were exposed to 250mGy of 60 Co γ-rays. Increases in the dicentric yields in the lymphocytes were observed with increased distances from the surface of the water phantom. As a variation of the dicentric yield with increasing distance in water was found, in the experiment to obtain calibration curves for biological dosimetry, it is recommended that blood samples should be positioned at a constant distance from the surface of a water phantom at the time of irradiation. ICRU REPORT 23 recommends that the calibration measurement be carried out with an ionization chamber positioned at 5cm depth below the surface of a water phantom for 150 kV-10 MV X rays, and 137 Cs and 60 Co γ-rays. As the same reasons which determine a 5cm depth in the recommendation, should be applied to this case, it is desirable that the experiment be carried out with blood samples positioned at 5cm distance from the surface of a water phantom. (author)

  12. On sample size of the kruskal-wallis test with application to a mouse peritoneal cavity study.

    Science.gov (United States)

    Fan, Chunpeng; Zhang, Donghui; Zhang, Cun-Hui

    2011-03-01

    As the nonparametric generalization of the one-way analysis of variance model, the Kruskal-Wallis test applies when the goal is to test the difference between multiple samples and the underlying population distributions are nonnormal or unknown. Although the Kruskal-Wallis test has been widely used for data analysis, power and sample size methods for this test have been investigated to a much lesser extent. This article proposes new power and sample size calculation methods for the Kruskal-Wallis test based on the pilot study in either a completely nonparametric model or a semiparametric location model. No assumption is made on the shape of the underlying population distributions. Simulation results show that, in terms of sample size calculation for the Kruskal-Wallis test, the proposed methods are more reliable and preferable to some more traditional methods. A mouse peritoneal cavity study is used to demonstrate the application of the methods. © 2010, The International Biometric Society.

  13. Virtual rough samples to test 3D nanometer-scale scanning electron microscopy stereo photogrammetry.

    Science.gov (United States)

    Villarrubia, J S; Tondare, V N; Vladár, A E

    2016-01-01

    The combination of scanning electron microscopy for high spatial resolution, images from multiple angles to provide 3D information, and commercially available stereo photogrammetry software for 3D reconstruction offers promise for nanometer-scale dimensional metrology in 3D. A method is described to test 3D photogrammetry software by the use of virtual samples-mathematical samples from which simulated images are made for use as inputs to the software under test. The virtual sample is constructed by wrapping a rough skin with any desired power spectral density around a smooth near-trapezoidal line with rounded top corners. Reconstruction is performed with images simulated from different angular viewpoints. The software's reconstructed 3D model is then compared to the known geometry of the virtual sample. Three commercial photogrammetry software packages were tested. Two of them produced results for line height and width that were within close to 1 nm of the correct values. All of the packages exhibited some difficulty in reconstructing details of the surface roughness.

  14. Measuring Student Achievement in Travel and Tourism. Sample Test Questions.

    Science.gov (United States)

    New York State Education Dept., Albany. Bureau of Business Education.

    The sample test items included in this document are intended as a resource for teachers of Marketing and Distributive Education programs with emphasis on hospitality and recreation marketing, and tourism and travel services marketing. The related curriculum material has been published in the Travel and Tourism syllabus, an advanced-level module in…

  15. Latent tuberculosis in HIV positive, diagnosed by the M. tuberculosis specific interferon-gamma test

    DEFF Research Database (Denmark)

    Brock, Inger; Ruhwald, Morten; Lundgren, Bettina

    2006-01-01

    BACKGROUND: Although tuberculosis (TB) is a minor problem in Denmark, severe and complicated cases occur in HIV positive. Since the new M. tuberculosis specific test for latent TB, the QuantiFERON-TB In-Tube test (QFT-IT) became available the patients in our clinic have been screened...

  16. Testing and sampling of deep brine aquifers in the Palo Duro Basin, West Texas

    International Nuclear Information System (INIS)

    Deyling, M.A.

    1984-01-01

    The US Department of Energy is investigating the Palo Duro Basin of West Texas along with locations in Nevada, Washington, Utah, Mississippi and Louisiana as potential sites for storage of high-level nuclear waste. Ten wells have been drilled to depths between 3000 and 8300 feet. Testing and sampling of deep test zones requires advance planning and analysis of what must be obtained from the well. Various alternatives are available depending on data needs. In this particular instance, both hydrologic and geochemical data were required. The methods chosen were field proven methods used in the oil field industry for many years. Short term testing has included conventional oil-field-type drill stem tests and drill stem equipment with surface pressure readout. Long term testing has consisted of a series of production and recovery tests. Fluid sampling was performed in two stages. The first was at the well head under an imposed pressure of several hundred psi. The second fluid samples were collected downhole at the production zone under pressures close to ambient pressure. The geochemical data and hydrologic data can be used as independent checks on each other in many cases. Test results from the well along with examination of recovered core provided maximum data for each well. 5 references, 8 figures

  17. A simple nomogram for sample size for estimating sensitivity and specificity of medical tests

    Directory of Open Access Journals (Sweden)

    Malhotra Rajeev

    2010-01-01

    Full Text Available Sensitivity and specificity measure inherent validity of a diagnostic test against a gold standard. Researchers develop new diagnostic methods to reduce the cost, risk, invasiveness, and time. Adequate sample size is a must to precisely estimate the validity of a diagnostic test. In practice, researchers generally decide about the sample size arbitrarily either at their convenience, or from the previous literature. We have devised a simple nomogram that yields statistically valid sample size for anticipated sensitivity or anticipated specificity. MS Excel version 2007 was used to derive the values required to plot the nomogram using varying absolute precision, known prevalence of disease, and 95% confidence level using the formula already available in the literature. The nomogram plot was obtained by suitably arranging the lines and distances to conform to this formula. This nomogram could be easily used to determine the sample size for estimating the sensitivity or specificity of a diagnostic test with required precision and 95% confidence level. Sample size at 90% and 99% confidence level, respectively, can also be obtained by just multiplying 0.70 and 1.75 with the number obtained for the 95% confidence level. A nomogram instantly provides the required number of subjects by just moving the ruler and can be repeatedly used without redoing the calculations. This can also be applied for reverse calculations. This nomogram is not applicable for testing of the hypothesis set-up and is applicable only when both diagnostic test and gold standard results have a dichotomous category.

  18. [The exploration on optimization of two alternatives between roll test and Dix-Hallpike test in benign paroxysmal positional vertigo].

    Science.gov (United States)

    Ji, R; Chen, T S; Wang, W; Xu, K X; Li, S S; Wen, C; Liu, Q; Lin, P

    2017-06-07

    Objective: To analyze the objective characteristics of roll test and Dix-Hallpike test in benign paroxysmal positional vertigo(BPPV)patients, discussing the premier solution of positional test. Methods: A total of 230 patients with BPPV, whereas 170 posterior semicircular canal canalithiasis (PSC-Can) BPPV and 60 horizontal semicircular canal canalithiasis (HSC-Can) BPPV were involved respectively. The induced nystagmus in roll test and Dix-Hallpike test was recorded by video nystagmuo graph (VNG), and the direction, intensity and time characteristics of nystagmus were compared in various BPPV.SPSS19.0 software was used for statistical analysis. Results: Vertically upward nystagmus was induced by hanging in 170 PSC-Can Dix-Hallpike test, and the nystagmus reversed and turned weaker when the subjects came to sit. The intensity of nystagmus at turning to lesion side by hanging and sitting were (30.3±14.1)°/s and (12.6±7.5)°/s respectively, the difference was statistically significant ( t =20.153, P <0.05). However, no nystagmus was induced in PSC-Can roll test. Horizontal nystagmus in the same direction with turning was induced in 60 HSC-Can roll test. The intensity of nystagmus at turning to lesion side and normal side was (42.0±18.0)°/s and (20.3±8.7)°/s respectively, the difference was statistically significant ( t =12.731, P <0.05). Furthermore, horizontal nystagmus in the same direction with turning was induced in 57 HSC-Can Dix-Hallpike. The coherence was 95% with the results of roll test. Conclusions: Dix-Hallpike test can not only be used to diagnose PSC-Can, but also induce nystagmus in HSC-Can effectively. Whereas the roll test only show significance in diagnosing HSC-Can. To avoid uncomfortable stimulation to patients as much as possible, we suggest to use Dix-Hallpike test at first, and to judge whether using roll test based on the result of the horizontal nystagmus.

  19. A Nested PCR Assay to Avoid False Positive Detection of the Microsporidian Enterocytozoon hepatopenaei (EHP) in Environmental Samples in Shrimp Farms

    Science.gov (United States)

    Jaroenlak, Pattana; Sanguanrut, Piyachat; Williams, Bryony A. P.; Stentiford, Grant D.; Flegel, Timothy W.; Sritunyalucksana, Kallaya

    2016-01-01

    Hepatopancreatic microsporidiosis (HPM) caused by Enterocytozoon hepatopenaei (EHP) is an important disease of cultivated shrimp. Heavy infections may lead to retarded growth and unprofitable harvests. Existing PCR detection methods target the EHP small subunit ribosomal RNA (SSU rRNA) gene (SSU-PCR). However, we discovered that they can give false positive test results due to cross reactivity of the SSU-PCR primers with DNA from closely related microsporidia that infect other aquatic organisms. This is problematic for investigating and monitoring EHP infection pathways. To overcome this problem, a sensitive and specific nested PCR method was developed for detection of the spore wall protein (SWP) gene of EHP (SWP-PCR). The new SWP-PCR method did not produce false positive results from closely related microsporidia. The first PCR step of the SWP-PCR method was 100 times (104 plasmid copies per reaction vial) more sensitive than that of the existing SSU-PCR method (106 copies) but sensitivity was equal for both in the nested step (10 copies). Since the hepatopancreas of cultivated shrimp is not currently known to be infected with microsporidia other than EHP, the SSU-PCR methods are still valid for analyzing hepatopancreatic samples despite the lower sensitivity than the SWP-PCR method. However, due to its greater specificity and sensitivity, we recommend that the SWP-PCR method be used to screen for EHP in feces, feed and environmental samples for potential EHP carriers. PMID:27832178

  20. A Nested PCR Assay to Avoid False Positive Detection of the Microsporidian Enterocytozoon hepatopenaei (EHP) in Environmental Samples in Shrimp Farms.

    Science.gov (United States)

    Jaroenlak, Pattana; Sanguanrut, Piyachat; Williams, Bryony A P; Stentiford, Grant D; Flegel, Timothy W; Sritunyalucksana, Kallaya; Itsathitphaisarn, Ornchuma

    2016-01-01

    Hepatopancreatic microsporidiosis (HPM) caused by Enterocytozoon hepatopenaei (EHP) is an important disease of cultivated shrimp. Heavy infections may lead to retarded growth and unprofitable harvests. Existing PCR detection methods target the EHP small subunit ribosomal RNA (SSU rRNA) gene (SSU-PCR). However, we discovered that they can give false positive test results due to cross reactivity of the SSU-PCR primers with DNA from closely related microsporidia that infect other aquatic organisms. This is problematic for investigating and monitoring EHP infection pathways. To overcome this problem, a sensitive and specific nested PCR method was developed for detection of the spore wall protein (SWP) gene of EHP (SWP-PCR). The new SWP-PCR method did not produce false positive results from closely related microsporidia. The first PCR step of the SWP-PCR method was 100 times (104 plasmid copies per reaction vial) more sensitive than that of the existing SSU-PCR method (106 copies) but sensitivity was equal for both in the nested step (10 copies). Since the hepatopancreas of cultivated shrimp is not currently known to be infected with microsporidia other than EHP, the SSU-PCR methods are still valid for analyzing hepatopancreatic samples despite the lower sensitivity than the SWP-PCR method. However, due to its greater specificity and sensitivity, we recommend that the SWP-PCR method be used to screen for EHP in feces, feed and environmental samples for potential EHP carriers.

  1. [Application of injection test in confirming the ideal position of esophageal balloon catheter].

    Science.gov (United States)

    Chen, Han; Xu, Ming; Yang, Yanlin; He, Xuan; Zhou, Jianxin

    2017-09-01

    To evaluate the safety and feasibility of injection test which is used to locate esophageal balloon catheter. A prospective study was conducted. The patients undergoing invasive mechanical ventilation (MV) admitted to general intensive care unit (ICU) of Beijing Tiantan Hospital Affiliated to Capital Medical University from May 2015 and March 2017 were enrolled. The commercially available esophageal balloon catheter was modified to perform injection test. The catheter was withdrawn step by step and the injection test was repeated until the presence disturbance wave presented, which indicated that the balloon had just entered the esophagus. The position where disturbance wave appears was named 0 cm. End-expiratory occlusions were performed at the positions of +15, +10, +5, 0, -5, -10 and -15 cm, respectively, and the changes of esophageal pressure (Pes) and airway pressures (Paw) were measured in the spontaneous breathing and passive ventilation, and the ratio between the changes (ΔPes/ΔPaw) was calculated. A total of 20 patients were enrolled, of which 15 patients finished both the spontaneous and the passive ventilation parts, and 2 patients finished only the spontaneous part and 3 patients finished only passive part. (1) Disturbance waves could be induced by injection test in all patients. The average depth of disturbance wave in spontaneous breathing was deeper than that in passive ventilation (cm: 42.4±3.8 vs. 41.8±3.3), but there was no significant difference between the two ventilation settings (P = 0.132). No adverse events occurred during the study period. (2) Pes increased with the stepwise withdraw of esophageal catheter, reached the maximal value at +5 cm, and then decreased when the catheter was further withdrawn, no matter in the spontaneous or the passive ventilation. In spontaneous breathing, the ΔPes/ΔPaw was within the ideal range (0.8-1.2) at the positions of 0, -5 and -10 cm. The ΔPes/ΔPaw was closest to unity at the positions of 0 cm (0

  2. Estimation of sample size and testing power (part 6).

    Science.gov (United States)

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2012-03-01

    The design of one factor with k levels (k ≥ 3) refers to the research that only involves one experimental factor with k levels (k ≥ 3), and there is no arrangement for other important non-experimental factors. This paper introduces the estimation of sample size and testing power for quantitative data and qualitative data having a binary response variable with the design of one factor with k levels (k ≥ 3).

  3. Evaluation of a Positive Youth Development Program Based on the Repertory Grid Test

    Directory of Open Access Journals (Sweden)

    Daniel T. L. Shek

    2012-01-01

    Full Text Available The repertory grid test, based on personal construct psychology, was used to evaluate the effectiveness of Project P.A.T.H.S. (Positive Adolescent Training through Holistic Social Programmes in Hong Kong. One hundred and four program participants (n=104 were randomly invited to complete a repertory grid based on personal construct theory in order to provide both quantitative and qualitative data for measuring self-identity changes after joining the program. Findings generally showed that the participants perceived that they understood themselves better and had stronger resilience after joining the program. Participants also saw themselves as closer to their ideal selves and other positive role figures (but farther away from a loser after joining the program. This study provides additional support for the effectiveness of the Tier 1 Program of Project P.A.T.H.S. in the Chinese context. This study also shows that the repertory grid test is a useful evaluation method to measure self-identity changes in participants in positive youth development programs.

  4. Testing Comprehensive Models of Disclosure of Sexual Orientation in HIV-Positive Latino Men Who Have Sex with Men (MSM)

    Science.gov (United States)

    Lechuga, Julia; Zea, María Cecilia

    2012-01-01

    Individuals who disclose their sexual orientation are more likely to also disclose their HIV status. Disclosure of HIV-serostatus is associated with better health outcomes. The goal of this study was to build and test comprehensive models of sexual orientation that included 8 theory-informed predictors of disclosure to mothers, fathers, and closest friends in a sample of HIV-positive Latino gay and bisexual men. US acculturation, gender non-conformity to hegemonic masculinity in self-presentation, comfort with sexual orientation, gay community involvement, satisfaction with social support, sexual orientation and gender of the closest friend emerged as significant predictors of disclosure of sexual orientation. PMID:22690708

  5. Evaluation of Legionella real-time PCR against traditional culture for routine and public health testing of water samples.

    Science.gov (United States)

    Collins, S; Stevenson, D; Walker, J; Bennett, A

    2017-06-01

    To evaluate the usefulness of Legionella qPCR alongside traditional culture for enumeration of Legionella from water samples as part of both routine and public health investigation testing. Routine water samples (n = 2002) and samples from public health investigations (n = 215) were analysed by culture and qPCR for Legionella spp., Legionella pneumophila and L. pneumophila sg-1. A negative qPCR result was highly predictive of a negative culture result for all water systems (negative predictive values, NPV from 97·4 to 100%). Positive predictive values (PPV) were lower (0-50%). Results for qPCR were generally larger than culture with average log 10 differences of 1·1 for Legionella spp. and 1·2 for L. pneumophila. Alert and action levels of 1000 and 10 000 GU per litre, respectively, are proposed for Legionella qPCR for hot and cold water systems (HCWS). The use of qPCR significantly reduced the time to results for public health investigations by rapidly identifying potential sources and ruling out others, thus enabling a more rapid and efficient response. The high NPV of qPCR supports its use to rapidly screen out negative samples without culture. Alert and action levels for Legionella qPCR for HCWS are proposed. Quantitative PCR will be a valuable tool for both routine and public health testing. This study generated comparative data of >2000 water samples by qPCR and culture. Action and alert levels have been recommended that could enable duty holders to interpret qPCR results to facilitate timely Legionella control and public health protection. © 2017 Crown copyright. Journal of Applied Microbiology © 2017 The Society for Applied Microbiology.

  6. False-positive result when a diphenylcarbazide spot test is used on trivalent chromium-passivated zinc surfaces

    DEFF Research Database (Denmark)

    Reveko, Valeriia; Lampert, Felix; Din, Rameez Ud

    2018-01-01

    chromium passivation on zinc; however, subsequent analysis by XPS could not confirm the presence of chromium in a hexavalent state. Conclusions Unintended oxidation of DPC induced by atmospheric corrosion is suggested as a possible reason for the false-positive reaction of the DPC test on a trivalent......A colorimetric 1,5-diphenylcarbazide (DPC)-based spot test can be used to identify hexavalent chromium on various metallic and leather surfaces. DPC testing on trivalent chromium-passivated zinc surfaces has unexpectedly given positive results in some cases, apparently indicating the presence...... of hexavalent chromium; however, the presence of hexavalent chromium has never been confirmed with more sensitive and accurate test methods. Objectives To examine the presence of hexavalent chromium on trivalent chromium-passivated zinc surfaces with a DPC-based spot test. Methods A colorimetric DPC spot test...

  7. Shrinkage-based diagonal Hotelling’s tests for high-dimensional small sample size data

    KAUST Repository

    Dong, Kai

    2015-09-16

    DNA sequencing techniques bring novel tools and also statistical challenges to genetic research. In addition to detecting differentially expressed genes, testing the significance of gene sets or pathway analysis has been recognized as an equally important problem. Owing to the “large pp small nn” paradigm, the traditional Hotelling’s T2T2 test suffers from the singularity problem and therefore is not valid in this setting. In this paper, we propose a shrinkage-based diagonal Hotelling’s test for both one-sample and two-sample cases. We also suggest several different ways to derive the approximate null distribution under different scenarios of pp and nn for our proposed shrinkage-based test. Simulation studies show that the proposed method performs comparably to existing competitors when nn is moderate or large, but it is better when nn is small. In addition, we analyze four gene expression data sets and they demonstrate the advantage of our proposed shrinkage-based diagonal Hotelling’s test.

  8. Shrinkage-based diagonal Hotelling’s tests for high-dimensional small sample size data

    KAUST Repository

    Dong, Kai; Pang, Herbert; Tong, Tiejun; Genton, Marc G.

    2015-01-01

    DNA sequencing techniques bring novel tools and also statistical challenges to genetic research. In addition to detecting differentially expressed genes, testing the significance of gene sets or pathway analysis has been recognized as an equally important problem. Owing to the “large pp small nn” paradigm, the traditional Hotelling’s T2T2 test suffers from the singularity problem and therefore is not valid in this setting. In this paper, we propose a shrinkage-based diagonal Hotelling’s test for both one-sample and two-sample cases. We also suggest several different ways to derive the approximate null distribution under different scenarios of pp and nn for our proposed shrinkage-based test. Simulation studies show that the proposed method performs comparably to existing competitors when nn is moderate or large, but it is better when nn is small. In addition, we analyze four gene expression data sets and they demonstrate the advantage of our proposed shrinkage-based diagonal Hotelling’s test.

  9. [Utilization of self-sampling kits for HPV testing in cervical cancer screening - pilot study].

    Science.gov (United States)

    Ondryášová, H; Koudeláková, V; Drábek, J; Vaněk, P; Slavkovský, R; Hajdúch, M

    2015-12-01

    To get initial experience with alternative sampling (self-sampling) for HPV testing as the means of cervical cancer screening program. Original work. Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University in Olomouc. Based on expression of interest, 215 self-sampling kits were posted to women. Evalyn(®) Brush Vaginal swabs obtained by self-sampling were analyzed for the presence of HPV infection by Cobas 4800 HPV (Roche) followed by genotyping using PapilloCheck(®) HPV-Screening (Greiner Bio-One). Sixty women randomly chosen from our sample were sent a questionnaire focused on their experience with self-sampling. One hundred seventy-four of 215 (81%) distributed self-sampling devices have been delivered to analysis. All cervicovaginal swabs were sampled correctly and it was possible to analyze them by Cobas 4800 HPV test. Similarly, 98% (171/174) samples were analyzable by PapilloCheck(®) HPV-Screening.One hundred twenty-five (72%) of 174 tested samples were HPV negative. Low risk HPV infection was detected only in 7 samples (4%), and high risk HPV (hrHPV) infection was present in 42 samples (24%). The most frequently detected hrHPV genotypes were HPV16 (11/42; 26%) and HPV53 (6/42; 14%). HrHPV co-infection was detected in 10 cases, in 5 of them lrHPV infection was find also.Of the 60 questionnaires, 48 (80%) were returned. From this group, 47 (98%) women rated their experience with self-sampling device as good to excellent. User manual of self-sampling device was considered good to excellent by all women (100%). All women also rated the convenience of self-sampling device using as good to excellent. As expected, most of the women (n = 42 [88%]) preferred self-sampling to physician sampling. Cervicovaginal self-sampling leads to valid results of HPV screening using two molecular genetics methods and was accepted by Czech women very well. The self-sampling as an opportunity to participate in cervical cancer

  10. 40 CFR 53.63 - Test procedure: Wind tunnel inlet aspiration test.

    Science.gov (United States)

    2010-07-01

    ... the sampler inlet opening centered in the sampling zone. To meet the maximum blockage limit of § 53.62(c)(1) or for convenience, part of the test sampler may be positioned external to the wind tunnel... = reference method sampler volumetric flow rate; and t = sampling time. (iii) Remove the reference method...

  11. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    Science.gov (United States)

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  12. Correlation between chronic arthritis patients confirmed with questionnaire and serologic test of Lyme disease

    Science.gov (United States)

    Rotan, H.; Ginting, Y.; Loesnihari, R.; Kembaren, T.; Marpaung, B.

    2018-03-01

    Lyme borreliosis is the most common tick-borne disease, and frequency of arthritis complication later. The objective of this study was to determine the seroprevalence of Lyme disease and to evaluate its correlation with chronic arthritis. This epidemiologic cross sectional study included 41 healthy individuals who had chronic arthritis and bitten by ticks underwent questionnaires, and laboratory tests consisted of a routine blood sample, serum uric acid, and IgG ELISA for Lyme. There was 7.32% presence of positive IgG for Lyme. Samples with positive IgG for Lyme were further evaluated for rheumatology marker. We found three samples with a positive rheumatoid factor, two samples had positive anti-MCV, and 1 sample had slightly increased CRP. Three Lyme positive samples had normal EULAR scoring. It was the first Lyme disease case found in Indonesia, particularly in 4 villages of Sibolangit, Deli Serdang, North Sumatera. The assessment made by analysis the questionnaire, evaluation the blood test, and confirmed positive Lyme disease, and at last, we found the correlation between chronic arthritis with positive test Lyme.

  13. Testing the sampling efficiency of a nuclear power station stack monitor

    Energy Technology Data Exchange (ETDEWEB)

    Stroem, L.H. [Instrumentinvest, Nykoeping (Sweden)

    1997-08-01

    The test method comprises the injection of known amounts of monodisperse particles in the stack air stream, at a suitable point upstream of the sampling installation. To find a suitable injection polls, the gas flow was mapped by means of a tracer gas, released in various points in the stack base. The resulting concentration distributions at the stack sampler level were observed by means of an array of gas detectors. An injection point that produced symmetrical distribution over the stack area, and low concentrations at the stack walls was selected for the particle tests. Monodisperse particles of 6, 10, and 19 {mu}m aerodynamic diameter, tagged with dysprosium, were dispersed in the selected injection point. Particle concentration at the sampler level was measured. The losses to the stack walls were found to be less than 10 %. The particle concentrations at the four sampler inlets were calculated from the observed gas distribution. The amount calculated to be aspirated into the sampler piping was compared with the quantity collected by the sampling train ordinary filter, to obtain the sampling line transmission efficiency. 1 ref., 2 figs.

  14. 36 CFR 9.42 - Well records and reports, plots and maps, samples, tests and surveys.

    Science.gov (United States)

    2010-07-01

    ... Well records and reports, plots and maps, samples, tests and surveys. Any technical data gathered... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Well records and reports, plots and maps, samples, tests and surveys. 9.42 Section 9.42 Parks, Forests, and Public Property...

  15. Diagnosis of pulmonary infection with Toxoplasma gondii in immunocompromised HIV-positive patients by real-time PCR

    DEFF Research Database (Denmark)

    Petersen, E.; Edvinsson, B.; Lundgren, Bettina

    2006-01-01

    . In positive samples, the genotype of the parasite was determined by sequence analysis of the GRA6 gene. Positive results were achieved for 2% (7/332) of the samples tested. Genotyping was possible in two samples and revealed GRA6 type II T. gondii. PCR for detecting T. gondii in BAL samples should...... be performed in all immunosuppressed HIV-positive patients with symptoms of a systemic infection of unknown etiology. Trimethoprim-sulfamethoxazole prophylaxis does not exclude concomitant infection with T. gondii....

  16. X-ray diffraction without sample preparation: Proof-of-principle experiments

    International Nuclear Information System (INIS)

    Hansford, Graeme M.

    2013-01-01

    The properties of a novel X-ray diffraction (XRD) technique having very low sensitivity to the sample morphology were previously elucidated through theoretical considerations and model simulations (Hansford, 2011). This technique opens up the possibility of mineralogical analysis by XRD without sample preparation. Here, the results of proof-of-principle experimental tests are presented. Two sets of experiments were performed using a vacuum chamber equipped with an X-ray tube source, sample holder and charge-coupled detector. Firstly, a pressed-powder pellet of α-quartz was placed in three different positions relative to the X-ray source and detector. The changes in position represent gross sample movements which would be inconceivable in conventional XRD analysis. The resulting back-reflection energy-dispersive spectra show a very high degree of correspondence other than an overall intensity factor dependent on the distance between the sample and detector. Secondly, the back-reflection spectrum of an unprepared limestone hand specimen, having mm-scale surface morphology, was compared to the spectrum of a calcite pressed-powder pellet. The correspondence of the diffraction peaks in the spectra demonstrate that the limestone is comprised dominantly of calcite. In both cases, the claims of the earlier paper are fully supported by the results of these experimental tests. -- Highlights: • Proof-of-principle tests of a novel X-ray diffraction (XRD) method were conducted. • Very low sensitivity to sample position and orientation was demonstrated. • Insensitivity to sample morphology is inferred. • A simple analysis of an unprepared limestone hand specimen was performed. • This technique enables mineralogical analysis by XRD without sample preparation

  17. Latent tuberculosis in HIV positive, diagnosed by the M. tuberculosis specific interferon-gamma test

    DEFF Research Database (Denmark)

    Brock, Inger; Ruhwald, Morten; Lundgren, Bettina

    2006-01-01

    Although tuberculosis (TB) is a minor problem in Denmark, severe and complicated cases occur in HIV positive. Since the new M. tuberculosis specific test for latent TB, the QuantiFERON-TB In-Tube test (QFT-IT) became available the patients in our clinic have been screened for the presence of latent...

  18. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Science.gov (United States)

    2010-04-01

    ... OTC test sample collection systems for drugs of abuse testing. 809.40 Section 809.40 Food and Drugs... Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs of abuse testing. (a) Over-the-counter (OTC) test sample collection systems for drugs of abuse testing (§ 864.3260...

  19. A technique for extracting blood samples from mice in fire toxicity tests

    Science.gov (United States)

    Bucci, T. J.; Hilado, C. J.; Lopez, M. T.

    1976-01-01

    The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.

  20. Detection of Chlamydophila psittaci from feral pigeons in environmental samples: problems with currently available techniques.

    Science.gov (United States)

    Geigenfeind, Ila; Haag-Wackernagel, Daniel

    2010-03-01

    Chlamydophila psittaci (Lillie, 1930) Everett et al., 1999, the pathogenic agent of human ornithosis, is widespread in feral pigeon populations and many cases of transmission from feral pigeons to humans have been reported. The aim of the present study was to detect C. psittaci in environmental samples to find out more about possible transmission routes and, therefore, to assess the zoonotic risk for humans. Fecal samples were collected from nest boxes in a feral pigeon loft. Additionally, samples were taken from the feather dust film covering the water surface of public fountains where pigeons regularly bathe. The samples were tested for the presence of chlamydial antigen using an antigen enzyme-linked immunosorbent assay to prove shedding of C. psittaci by feral pigeons. This test detects a genus specific lipopolysaccharide in the outer membrane of the chlamydial bacteria. Samples were tested using the IDEIA PCE Chlamydia Test kit (DakoCytomation) and positive results were verified with IDEIA Chlamydia Blocking Reagents (DakoCytomation). The IDEIA PCE Chlamydia Test yields a high proportion of positive results. However, when IDEIA Chlamydia Blocking was performed, most of the positive results turned out to be negative or could not be interpreted. We conclude that antigen-enzyme-linked immunosorbent assay tests are not suitable for detecting C. psittaci in environmental samples. Previous publications where no blocking test was used should be reconsidered critically. © 2010 ISZS, Blackwell Publishing and IOZ/CAS.

  1. Development of a short sample test facility for evaluating superconducting wires

    International Nuclear Information System (INIS)

    Singh, M.R.; Kulkarni, D.G.; Sahni, V.C.; Ravikumar, G.; Patel, K.L.

    2002-01-01

    In this paper we describe a short sample test facility we have set up at Bhabha Atomic Research Centre (BARC). This facility has been used to measure critical currents of NbTi/Cu composite superconducting wires by recording V versus I data at 4.2 K. It offers sample current as large as 1500 A and a transverse magnetic field up to 7.4 T. A power law, V ∼I n( H) is fitted to the resistive transition region to estimate the exponent n, which is a measure of the uniformity of superconducting filaments in composite wires. It is observed that inadequate thermal stabilization of sample wire results in thermal runaway, which limits the V-I data to∼ 2μ V . This in turn affects the reliability of estimated filament uniformity. To mitigate this problem, we have used a sample holder made of OFHC-Cu which enhances thermal stabilization of the sample. With this sample holder, the results of measurements carried out on wires developed by the Atomic Fuel Division, BARC show a high filament uniformity (n ∼ 58). (author)

  2. Risks of Using Bedside Tests to Verify Nasogastric Tube Position in Adult Patients

    Directory of Open Access Journals (Sweden)

    Melody Ni

    2014-12-01

    Full Text Available Nasogastric (NG tubes are commonly used for enteral feeding. Complications of feeding tube misplacement include malnutrition, pulmonary aspiration, and even death. We built a Bayesian network (BN to analyse the risks associated with available bedside tests to verify tube position. Evidence on test validity (sensitivity and specificity was retrieved from a systematic review. Likelihood ratios were used to select the best tests for detecting tubes misplaced in the lung or oesophagus. Five bedside tests were analysed including magnetic guidance, aspirate pH, auscultation, aspirate appearance, and capnography/colourimetry. Among these, auscultation and appearance are non-diagnostic towards lung or oesophagus placements. Capnography/ colourimetry can confirm but cannot rule out lung placement. Magnetic guidance can rule out both lung and oesophageal placement. However, as a relatively new technology, further validation studies are needed. The pH test with a cut-off at 5.5 or lower can rule out lung intubation. Lowering the cut-off to 4 not only minimises oesophageal intubation but also provides extra safety as the sensitivity of pH measurement is reduced by feeding, antacid medication, or the use of less accurate pH paper. BN is an effective tool for representing and analysing multi-layered uncertainties in test validity and reliability for the verification of NG tube position. Aspirate pH with a cut-off of 4 is the safest bedside method to minimise lung and oesophageal misplacement.

  3. Swab2know: An HIV-Testing Strategy Using Oral Fluid Samples and Online Communication of Test Results for Men Who Have Sex With Men in Belgium.

    Science.gov (United States)

    Platteau, Tom; Fransen, Katrien; Apers, Ludwig; Kenyon, Chris; Albers, Laura; Vermoesen, Tine; Loos, Jasna; Florence, Eric

    2015-09-01

    As HIV remains a public health concern, increased testing among those at risk for HIV acquisition is important. Men who have sex with men (MSM) are the most important group for targeted HIV testing in Europe. Several new strategies have been developed and implemented to increase HIV-testing uptake in this group, among them the Swab2know project. In this project, we aim to assess the acceptability and feasibility of outreach and online HIV testing using oral fluid samples as well as Web-based delivery of test results. Sample collection happened between December 2012 and April 2014 via outreach and online sampling among MSM. Test results were communicated through a secured website. HIV tests were executed in the laboratory. Each reactive sample needed to be confirmed using state-of-the-art confirmation procedures on a blood sample. Close follow-up of participants who did not pick up their results, and those with reactive results, was included in the protocol. Participants were asked to provide feedback on the methodology using a short survey. During 17 months, 1071 tests were conducted on samples collected from 898 men. Over half of the samples (553/1071, 51.63%) were collected during 23 outreach sessions. During an 8-month period, 430 samples out of 1071 (40.15%) were collected from online sampling. Additionally, 88 samples out of 1071 (8.22%) were collected by two partner organizations during face-to-face consultations with MSM and male sex workers. Results of 983 out of 1071 tests (91.78%) had been collected from the website. The pickup rate was higher among participants who ordered their kit online (421/430, 97.9%) compared to those participating during outreach activities (559/641, 87.2%; Ponline participants were more likely to have never been tested before (17.3% vs 10.0%; P=.001) and reported more sexual partners in the 6 months prior to participation in the project (mean 7.18 vs 3.23; Ponline counseling tool), and in studying the cost effectiveness of the

  4. Assessing Acceptability of Self-Sampling Kits, Prevalence, and Risk Factors for Human Papillomavirus Infection in American Indian Women.

    Science.gov (United States)

    Winer, Rachel L; Gonzales, Angela A; Noonan, Carolyn J; Cherne, Stephen L; Buchwald, Dedra S

    2016-10-01

    We evaluated the feasibility and acceptability of self-sampling for human papillomavirus (HPV) testing and calculated the prevalence of and risk factors for high-risk (hr) HPV infections in a community-based sample of American Indian women. To this end, we recruited 329 Hopi women aged 21-65 years to self-collect vaginal samples for hrHPV testing. Samples were tested by polymerase chain reaction for 14 hrHPV genotypes. We used Chi square tests to identify correlates of preference for clinician Pap testing versus HPV self-sampling, and age-adjusted Poisson regression to evaluate correlates of hrHPV prevalence. We found that satisfaction with HPV self-sampling was high, with 96 % of women reporting that the sample was easy to collect and 87 % reporting no discomfort. The majority (62 %) indicated that they preferred HPV self-sampling to receiving a Pap test from a clinician. Preference for Pap testing over HPV self-sampling was positively associated with adherence to Pap screening and employment outside the home. All samples evaluated were satisfactory for HPV testing, and 22 % were positive for hrHPV. HrHPV prevalence peaked in the late 20 s and declined with increasing age. HrHPV positivity was inversely associated with having children living the household. In conclusion, HPV self-sampling is feasible and acceptable to Hopi women, and could be effective in increasing rates of cervical cancer screening in Hopi communities. HrHPV prevalence was similar to estimates in the general United States population.

  5. Evaluation of a PCR Assay for Detection of Streptococcus pneumoniae in Respiratory and Nonrespiratory Samples from Adults with Community-Acquired Pneumonia

    Science.gov (United States)

    Murdoch, David R.; Anderson, Trevor P.; Beynon, Kirsten A.; Chua, Alvin; Fleming, Angela M.; Laing, Richard T. R.; Town, G. Ian; Mills, Graham D.; Chambers, Stephen T.; Jennings, Lance C.

    2003-01-01

    Streptococcus pneumoniae is the most common cause of community-acquired pneumonia, but it is undoubtedly underdiagnosed. We used a nested PCR assay (targeting the pneumolysin gene) to detect S. pneumoniae DNA in multiple sample types from 474 adults with community-acquired pneumonia and 183 control patients who did not have pneumonia. Plasma or buffy coat samples were PCR positive in only 6 of the 21 patients with positive blood cultures for S. pneumoniae and in 12 other patients (4 of whom had no other laboratory evidence of S. pneumoniae infection). Buffy coat samples from two control patients (neither having evidence of S. pneumoniae infection), but no control plasma samples, were PCR positive. Although pneumococcal antigen was detected in the urine from 120 of 420 (29%) patients, only 4 of 227 (2%) urine samples tested were PCR positive. Overall, 256 of 318 (81%) patients had PCR-positive sputum samples, including 58 of 59 samples from which S. pneumoniae was cultured. Throat swab samples from 229 of 417 (55%) patients were PCR positive and, in those who produced sputum, 96% also had positive PCR results from sputum. Throat swabs from 73 of 126 (58%) control patients were also PCR positive. We conclude that the pneumolysin PCR assay adds little to existing diagnostic tests for S. pneumoniae and is unable to distinguish colonization from infection when respiratory samples are tested. PMID:12517826

  6. Longitudinal investigation on learned helplessness tested under negative and positive reinforcement involving stimulus control.

    Science.gov (United States)

    Oliveira, Emileane C; Hunziker, Maria Helena

    2014-07-01

    In this study, we investigated whether (a) animals demonstrating the learned helplessness effect during an escape contingency also show learning deficits under positive reinforcement contingencies involving stimulus control and (b) the exposure to positive reinforcement contingencies eliminates the learned helplessness effect under an escape contingency. Rats were initially exposed to controllable (C), uncontrollable (U) or no (N) shocks. After 24h, they were exposed to 60 escapable shocks delivered in a shuttlebox. In the following phase, we selected from each group the four subjects that presented the most typical group pattern: no escape learning (learned helplessness effect) in Group U and escape learning in Groups C and N. All subjects were then exposed to two phases, the (1) positive reinforcement for lever pressing under a multiple FR/Extinction schedule and (2) a re-test under negative reinforcement (escape). A fourth group (n=4) was exposed only to the positive reinforcement sessions. All subjects showed discrimination learning under multiple schedule. In the escape re-test, the learned helplessness effect was maintained for three of the animals in Group U. These results suggest that the learned helplessness effect did not extend to discriminative behavior that is positively reinforced and that the learned helplessness effect did not revert for most subjects after exposure to positive reinforcement. We discuss some theoretical implications as related to learned helplessness as an effect restricted to aversive contingencies and to the absence of reversion after positive reinforcement. This article is part of a Special Issue entitled: insert SI title. Copyright © 2014. Published by Elsevier B.V.

  7. Eddy-current testing and analysis of a sample of Zircaloy fuel cladding for the OECD Halden 'Round-Robin' exercise (Phase II)

    International Nuclear Information System (INIS)

    Watson, P.C.; Cross, M.T.

    1987-02-01

    Two samples of Zircaloy fuel cladding were supplied, one containing pre-measured defects of known type and size, and the other containing unknown defects. Eddy-current testing techniques were used to ascertain the nature of the unknown defects. By using a high resolution encircling coil and a probe coil and then processing digitally the data with specially prepared software, nine internal defects, of volume 0.18 to 0.86 mm 3 were located positively and identified, despite interference from heavily fluctuating background signals. (author)

  8. Retention of children under 18 months testing HIV positive in care in ...

    African Journals Online (AJOL)

    Retention of children under 18 months testing HIV positive in care in Swaziland: a retrospective study. ... children within the first two months of life and linking them into care. However, as time progresses the retention of children in care declines. Innovative strategies need to be developed to enhance patient retention.

  9. Sample and injection manifolds used to in-place test of nuclear air-cleaning system

    International Nuclear Information System (INIS)

    Qiu Dangui; Li Xinzhi; Hou Jianrong; Qiao Taifei; Wu Tao; Zhang Jirong; Han Lihong

    2012-01-01

    Objective: According to the regulations of nuclear safety rules and related standards, in-place test of the nuclear air-cleaning systems should be carried out before and during operation of the nuclear facilities, which ensure them to be in good condition. In some special conditions, the use of sample and injection manifolds is required to make the test tracer and ventilating duct air fully mixed, so as to get the on-spot typical sample. Methods: This paper introduces the technology and application of the sample and injection manifolds in nuclear air-cleaning system. Results: Multi point injection and multi point sampling technology as an effective experimental method, has been used in a of domestic and international nuclear facilities. Conclusion: The technology solved the problem of uniformly of on-spot injection and sampling,which plays an important role in objectively evaluating the function of nuclear air-cleaning system. (authors)

  10. The APS x-ray undulator photon beam position monitor and tests at CHESS and NSLS

    International Nuclear Information System (INIS)

    Shu, D.; Rodricks, B.; Barraza, J.; Sanchez, T.; Kuzay, T.M.

    1992-01-01

    The advent of third generation synchrotron radiation sources, like the Advanced Photon Source (APS), will provide significant increases in brilliance over existing synchrotron sources. The APS x-ray undulators will increase the brilliance in the 3-40 KeV range by several orders of magnitude. Thus, the design of the photon beam position monitor is a challenging engineering task. The beam position monitors must withstand the high thermal load, be able to achieve sub-micron spatial resolution while maintaining their stability, and be compatible with both undulators and wigglers. A preliminary APS prototype photon beam position monitor consisting of a CVD-diamond-based, tungsten-coated blade was tested on the APS/CHESS undulator at the Cornell High Energy Synchrotron Radiation Source (CHESS) and on the NSLS X-13 undulator beamline. Results from these tests, as well as the design of this prototype APS photon beam position monitor, will be discussed in this paper

  11. The APS X-ray undulator photon beam position monitor and tests at CHESS and NSLS

    International Nuclear Information System (INIS)

    Shu, D.; Rodricks, B.; Barraza, J.; Sanchez, T.; Kuzay, T.M.

    1992-01-01

    The advent of thirs generation synchrotron sources, like the Advanced Photon Source (APS), will provide significant increases in brilliance over existing synchrotron sources. The APS X-ray undulators will increase the brilliance in the 3-40 keV range by several orders of magnitude. Thus, the design of the photon beam position monitor is a challenging engineering task. The beam position monitors must withstand the high thermal load, be able to achieve submicron spatial resolution while maintaining their stability, and be compatible with both undulators and wigglers. A preliminary APS prototype photon beam position monitor consisting of a CVD-diamond-based, tungsten-coated blade was tested on the APS/CHESS undulator at the Cornell High Energy Synchrotron Radiation Source (CHESS) and on the NSLS X-13 undulator beamline. Results from these tests, as well as the design of this prototype APS photon beam position monitor, will be discussed in this paper. (orig.)

  12. Simulation of Model Force-Loading with Changing Its Position in the Wind Tunnel Test Section

    Directory of Open Access Journals (Sweden)

    V. T. Bui

    2015-01-01

    Full Text Available When planning and implementing an aerodynamic experiment, model sizes and its position in the test section of the wind tunnel (WT play very important role. The paper focuses on the value variations of the aerodynamic characteristics of a model through changing its position in the WT test section and on the attenuation of the velocity field disturbance in front of the model. Flow around aerodynamic model profile in the open test section of the low-speed WT T-500 is simulated at BMSTU Department SM3. The problem is solved in a two-dimensional case using the ANSYS Fluent package. The mathematical model of flow is based on the Reynolds equations closed by the SST turbulence model. The paper also presents the results of the experiment. Experiments conducted in WT T-500 well correlate with the calculated data and show the optimal position in the middle of the test section when conducting the weighing and drainage experiments. Disturbance of tunnel dynamic pressure (velocity head and flow upwash around the model profile and circular cylinder in the WT test section is analyzed. It was found that flow upstream from the front stagnation point on the body weakly depends on the Reynolds number and obtained results can be used to assess the level of disturbances in the flow around a model by incompressible airflow.

  13. Correlation between working positions and lactic acid levels with musculoskeletal complaints among dentists

    Directory of Open Access Journals (Sweden)

    Fiory Dioptis Putriwijaya

    2016-12-01

    Full Text Available Background: Musculoskeletal complaints have been common for dentists since their body is unknowingly often in inappropriate positions when caring for patients. For example, they bend towards patients, suddenly move, and then rotate from one side to another. The repetitive movements are done in long term. High activities and sufficient recovery time can cause a buildup of lactic acid in their blood leading to obstruction of the energy intake from the aerobic system in their muscle cells, resulting in fatigue. As a result, such conditions trigger decreased muscle performances. Purpose: This study aimed to determine the correlation between working positions and lactic acid levels with the risk of musculoskeletal disorders among dentists at Public Health Centers in Surabaya. Method: This research was an analytical observational research using cross sectional approach. Sampling technique used in this research was cluster random sampling with nineteen samples. To evaluate the working positions of those samples, a rapid entire body assessment (REBA method was used. Meanwhile, to observe the musculoskeletal disorders of those samples, a Nordic body map was used. Data obtained then were analyzed using Pearson correlation test with a significance level (p<0.05. Result: Results of data analysis using the Pearson correlation test showed that the significance value obtained was 0.036. It indicates that there was a correlation between the working positions and the lactic acid levels with the musculoskeletal disorders in those dentists. The results of the Pearson correlation test also revealed that there was a correlation between the working positions and the lactic acid levels among those dentists with a significance value of 0.025. Conclusion: It may be concluded that the wrong body positions during working can increase lactic acid level in the body of dentists. The increased level of lactic acid then can affect their muscles, leading to the high risk of

  14. [Molecular diagnostics of ALK-positive lung cancer].

    Science.gov (United States)

    Tímár, József; Lotz, Gábor; Rásó, Erzsébet; Moldvay, Judit

    2017-09-20

    ALK translocation is the 3rd most frequent genetic aberration in lung adenocarcinoma, and several inhibitors are now clinically available in first and second line settings. Accordingly, molecular diagnostics of ALK-positive lung cancer is very important and can be done with the rational combination of several methods. All international recommendations suggest that, except for cytological samples, screening technology for ALK-positive tumors is immunohistochemistry using a validated test. It is highly recommended that in case of ALK protein positive samples gene translocation must be confirmed by fluorescent in situ hybridization (FISH). In case of cytological samples FISH technique must be used as ALK diagnostics. In equivocal cases the genetic alteration of ALK can be confirmed by alternative molecular techniques such as next generation sequencing or RNAbased PCR methods. Upon administration of ALK inhibitors, acquired resistance is frequent which is mostly due to ALK amplification and/or mutation. It is evident that the diagnostics of these secondary ALK gene alterations must be done from recurrent tumors or circulating nucleic acids.

  15. Basic distribution free identification tests for small size samples of environmental data

    Energy Technology Data Exchange (ETDEWEB)

    Federico, A.G.; Musmeci, F. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Ambiente

    1998-01-01

    Testing two or more data sets for the hypothesis that they are sampled form the same population is often required in environmental data analysis. Typically the available samples have a small number of data and often then assumption of normal distributions is not realistic. On the other hand the diffusion of the days powerful Personal Computers opens new possible opportunities based on a massive use of the CPU resources. The paper reviews the problem introducing the feasibility of two non parametric approaches based on intrinsic equi probability properties of the data samples. The first one is based on a full re sampling while the second is based on a bootstrap approach. A easy to use program is presented. A case study is given based on the Chernobyl children contamination data. [Italiano] Nell`analisi di dati ambientali ricorre spesso il caso di dover sottoporre a test l`ipotesi di provenienza di due, o piu`, insiemi di dati dalla stessa popolazione. Tipicamente i dati disponibili sono pochi e spesso l`ipotesi di provenienza da distribuzioni normali non e` sostenibile. D`altra aprte la diffusione odierna di Personal Computer fornisce nuove possibili soluzioni basate sull`uso intensivo delle risorse della CPU. Il rapporto analizza il problema e presenta la possibilita` di utilizzo di due test non parametrici basati sulle proprieta` intrinseche di equiprobabilita` dei campioni. Il primo e` basato su una tecnica di ricampionamento esaustivo mentre il secondo su un approccio di tipo bootstrap. E` presentato un programma di semplice utilizzo e un caso di studio basato su dati di contaminazione di bambini a Chernobyl.

  16. Robust non-parametric one-sample tests for the analysis of recurrent events.

    Science.gov (United States)

    Rebora, Paola; Galimberti, Stefania; Valsecchi, Maria Grazia

    2010-12-30

    One-sample non-parametric tests are proposed here for inference on recurring events. The focus is on the marginal mean function of events and the basis for inference is the standardized distance between the observed and the expected number of events under a specified reference rate. Different weights are considered in order to account for various types of alternative hypotheses on the mean function of the recurrent events process. A robust version and a stratified version of the test are also proposed. The performance of these tests was investigated through simulation studies under various underlying event generation processes, such as homogeneous and nonhomogeneous Poisson processes, autoregressive and renewal processes, with and without frailty effects. The robust versions of the test have been shown to be suitable in a wide variety of event generating processes. The motivating context is a study on gene therapy in a very rare immunodeficiency in children, where a major end-point is the recurrence of severe infections. Robust non-parametric one-sample tests for recurrent events can be useful to assess efficacy and especially safety in non-randomized studies or in epidemiological studies for comparison with a standard population. Copyright © 2010 John Wiley & Sons, Ltd.

  17. Mechanical characteristics of historic mortars from tests on small-sample non-standard on small-sample non-standard specimens

    Czech Academy of Sciences Publication Activity Database

    Drdácký, Miloš; Slížková, Zuzana

    2008-01-01

    Roč. 17, č. 1 (2008), s. 20-29 ISSN 1407-7353 R&D Projects: GA ČR(CZ) GA103/06/1609 Institutional research plan: CEZ:AV0Z20710524 Keywords : small-sample non-standard testing * lime * historic mortar Subject RIV: AL - Art, Architecture, Cultural Heritage

  18. Collecting Samples for Testing

    Science.gov (United States)

    ... Creatinine Ratio Valproic Acid Vancomycin Vanillylmandelic Acid (VMA) VAP Vitamin A Vitamin B12 and Folate Vitamin D ... that used for CSF in that they require aspiration of a sample of the fluid through a ...

  19. One, two or three dimensions of work engagement? Testing the factorial validity of the Utrecht Work Engagement Scale on a sample of Polish employees.

    Science.gov (United States)

    Kulikowski, Konrad

    2017-10-11

    Work engagement, as conceptualized by the Utrecht Work Engagement Scale (UWES), is a work-related positive state of mind that is characterized by vigour, dedication and absorption; however, it still remains unclear how many dimensions work engagement comprises. This study tested the factorial validity of 11 different UWES factorial models that are available in the literature using a confirmatory factor analysis approach on a large sample of multi-occupational Polish employees (N = 1420). The two-factor UWES-6, comprising vigour and dedication, was found to be reliable and remained invariant across samples drawn from four different organizational positions. It also presented a better fit than the three-factor UWES-9, which is a scale used as a standard in contemporary research on work engagement. The findings suggest that the three-factor UWES-9 might not be an optimal measure of work engagement in Poland.

  20. Research on Automatic Positioning System of Ultrasonic Testing of Wind Turbine Blade Flaws

    Science.gov (United States)

    Liu, Q. X.; Wang, Z. H.; Long, S. G.; Cai, M.; Cai, M.; Wang, X.; Chen, X. Y.; Bu, J. L.

    2017-11-01

    Ultrasonic testing technology has been used essentially in non-destructive testing of wind turbine blades. However, it is fact that the ultrasonic flaw detection method has inefficiently employed in recent years. This is because the testing result will illustrate a small deviation due to the artificial, environmental and technical factors. Therefore, it is an urgent technical demand for engineers to test the various flaws efficiently and quickly. An automatic positioning system has been designed in this paper to record the moving coordinates and the target distance in real time. Simultaneously, it could launch and acquire the sonic wave automatically. The ADNS-3080 optoelectronic chip is manufactured by Agilent Technologies Inc, which is also utilized in the system. With the combination of the chip, the power conversion module and the USB transmission module, the collected data can be transmitted from the upper monitor to the hardware that could process and control the data through software programming. An experiment has been designed to prove the reliability of automotive positioning system. The result has been validated by comparing the result collected form LABVIEW and actual plots on Perspex plane, it concludes that the system possesses high accuracy and magnificent meanings in practical engineering.

  1. Design and first tests of an acoustic positioning and detection system for KM3NeT

    Science.gov (United States)

    Simeone, F.; Ameli, F.; Ardid, M.; Bertin, V.; Bonori, M.; Bou-Cabo, M.; Calì, C.; D'Amico, A.; Giovanetti, G.; Imbesi, M.; Keller, P.; Larosa, G.; Llorens, C. D.; Masullo, R.; Randazzo, N.; Riccobene, G.; Speziale, F.; Viola, S.; KM3NeT Consortium

    2012-01-01

    In a deep-sea neutrino telescope it is mandatory to locate the position of the optical sensors with a precision of about 10 cm. To achieve this requirement, an innovative Acoustic Positioning System (APS) has been designed in the frame work of the KM3NeT neutrino telescope. The system will also be able to provide an acoustic guide during the deployment of the telescope’s components and seafloor infrastructures (junction boxes, cables, etc.). A prototype of the system based on the successful acoustic systems of ANTARES and NEMO is being developed. It will consist of an array of hydrophones and a network of acoustic transceivers forming the Long Baseline. All sensors are connected to the telescope data acquisition system and are in phase and synchronised with the telescope master clock. Data from the acoustic sensors, continuously sampled at 192 kHz, will be sent to shore where signal recognition and analysis will be carried out. The design and first tests of the system elements will be presented. This new APS is expected to have better precision compared to the systems used in ANTARES and NEMO, and can also be used as a real-time monitor of acoustic sources and environmental noise in deep sea.

  2. Flight-Test Evaluation of Kinematic Precise Point Positioning of Small UAVs

    Directory of Open Access Journals (Sweden)

    Jason N. Gross

    2016-01-01

    Full Text Available An experimental analysis of Global Positioning System (GPS flight data collected onboard a Small Unmanned Aerial Vehicle (SUAV is conducted in order to demonstrate that postprocessed kinematic Precise Point Positioning (PPP solutions with precisions approximately 6 cm 3D Residual Sum of Squares (RSOS can be obtained on SUAVs that have short duration flights with limited observational periods (i.e., only ~≤5 minutes of data. This is a significant result for the UAV flight testing community because an important and relevant benefit of the PPP technique over traditional Differential GPS (DGPS techniques, such as Real-Time Kinematic (RTK, is that there is no requirement for maintaining a short baseline separation to a differential GNSS reference station. Because SUAVs are an attractive platform for applications such as aerial surveying, precision agriculture, and remote sensing, this paper offers an experimental evaluation of kinematic PPP estimation strategies using SUAV platform data. In particular, an analysis is presented in which the position solutions that are obtained from postprocessing recorded UAV flight data with various PPP software and strategies are compared to solutions that were obtained using traditional double-differenced ambiguity fixed carrier-phase Differential GPS (CP-DGPS. This offers valuable insight to assist designers of SUAV navigation systems whose applications require precise positioning.

  3. Optimal Threshold for a Positive Hybrid Capture 2 Test for Detection of Human Papillomavirus: Data from the ARTISTIC Trial▿

    Science.gov (United States)

    Sargent, A.; Bailey, A.; Turner, A.; Almonte, M.; Gilham, C.; Baysson, H.; Peto, J.; Roberts, C.; Thomson, C.; Desai, M.; Mather, J.; Kitchener, H.

    2010-01-01

    We present data on the use of the Hybrid Capture 2 (HC2) test for the detection of high-risk human papillomavirus (HR HPV) with different thresholds for positivity within a primary screening setting and as a method of triage for low-grade cytology. In the ARTISTIC population-based trial, 18,386 women were screened by cytology and for HPV. Cervical intraepithelial neoplasia lesions of grade two and higher (CIN2+ lesions) were identified for 453 women within 30 months of an abnormal baseline sample. When a relative light unit/cutoff (RLU/Co) ratio of ≥1 was used as the threshold for considering an HC2 result positive, 15.6% of results were positive, and the proportion of CIN2+ lesions in this group was 14.7%. The relative sensitivity for CIN2+ lesion detection was 93.4%. When an RLU/Co ratio of ≥2 was used as the threshold, there was a 2.5% reduction in positivity, with an increase in the proportion of CIN2+ lesions detected. The relative sensitivity decreased slightly, to 90.3%. Among women with low-grade cytology, HPV prevalences were 43.7% and 40.3% at RLU/Co ratios of ≥1 and ≥2, respectively. The proportions of CIN2+ lesions detected were 17.3% and 18.0%, with relative sensitivities of 87.7% at an RLU/Co ratio of ≥1 and 84.2% at an RLU/Co ratio of ≥2. At an RLU/Co ratio of ≥1, 68.3% of HC2-positive results were confirmed by the Roche line blot assay, compared to 77.2% of those at an RLU/Co ratio of ≥2. Fewer HC2-positive results were confirmed for 35- to 64-year-olds (50.3% at an RLU/Co ratio of ≥1 and 63.2% at an RLU/Co ratio of >2) than for 20- to 34-year-olds (78.7% at an RLU/Co ratio of ≥1 and 83.7% at an RLU/Co ratio of >2). If the HC2 test is used for routine screening as an initial test or as a method of triage for low-grade cytology, we would suggest increasing the threshold for positivity from the RLU/Co ratio of ≥1, recommended by the manufacturer, to an RLU/Co ratio of ≥2, since this study has shown that a beneficial balance

  4. 43 CFR 11.64 - Injury determination phase-testing and sampling methods.

    Science.gov (United States)

    2010-10-01

    ... Institute for Occupational Safety and Health, the American Society for Testing and Materials, and the American Public Health Association. (iii) Methods selected for air sampling and analysis shall be methods... stresses simulated; (B) How the model approximates the geohydrological framework of the assessment area; (C...

  5. 40 CFR 53.23 - Test procedures.

    Science.gov (United States)

    2010-07-01

    ... deviation about the mean and is expressed in concentration units. (2) Test procedure. (i) Allow sufficient... definition. Positive or negative response caused by a substance other than the one being measured. (2) Test...) Before testing for each interferent, allow the test analyzer to sample through the scrubber a test...

  6. Analysis of fingerprint samples, testing various conditions, for forensic DNA identification.

    Science.gov (United States)

    Ostojic, Lana; Wurmbach, Elisa

    2017-01-01

    Fingerprints can be of tremendous value for forensic biology, since they can be collected from a wide variety of evident types, such as handles of weapons, tools collected in criminal cases, and objects with no apparent staining. DNA obtained from fingerprints varies greatly in quality and quantity, which ultimately affects the quality of the resulting STR profiles. Additional difficulties can arise when fingerprint samples show mixed STR profiles due to the handling of multiple persons. After applying a tested protocol for sample collection (swabbing with 5% Triton X-100), DNA extraction (using an enzyme that works at elevated temperatures), and PCR amplification (AmpFlSTR® Identifiler® using 31cycles) extensive analysis was performed to better understand the challenges inherent to fingerprint samples, with the ultimate goal of developing valuable profiles (≥50% complete). The impact of time on deposited fingerprints was investigated, revealing that while the quality of profiles deteriorated, full STR profiles could still be obtained from samples after 40days of storage at room temperature. By comparing the STR profiles from fingerprints of the dominant versus the non-dominant hand, we found a slightly better quality from the non-dominant hand, which was not always significant. Substrates seem to have greater effects on fingerprints. Tests on glass, plastic, paper and metal (US Quarter dollar, made of Cu and Ni), common substrates in offices and homes, showed best results for glass, followed by plastic and paper, while almost no profiles were obtained from a Quarter dollar. Important for forensic casework, we also assessed three-person mixtures of touched fingerprint samples. Unlike routinely used approaches for sampling evidence, the surface of an object (bottle) was sectioned into six equal parts and separate samples were taken from each section. The samples were processed separately for DNA extraction and STR amplification. The results included a few single

  7. Location tests for biomarker studies: a comparison using simulations for the two-sample case.

    Science.gov (United States)

    Scheinhardt, M O; Ziegler, A

    2013-01-01

    Gene, protein, or metabolite expression levels are often non-normally distributed, heavy tailed and contain outliers. Standard statistical approaches may fail as location tests in this situation. In three Monte-Carlo simulation studies, we aimed at comparing the type I error levels and empirical power of standard location tests and three adaptive tests [O'Gorman, Can J Stat 1997; 25: 269 -279; Keselman et al., Brit J Math Stat Psychol 2007; 60: 267- 293; Szymczak et al., Stat Med 2013; 32: 524 - 537] for a wide range of distributions. We simulated two-sample scenarios using the g-and-k-distribution family to systematically vary tail length and skewness with identical and varying variability between groups. All tests kept the type I error level when groups did not vary in their variability. The standard non-parametric U-test performed well in all simulated scenarios. It was outperformed by the two non-parametric adaptive methods in case of heavy tails or large skewness. Most tests did not keep the type I error level for skewed data in the case of heterogeneous variances. The standard U-test was a powerful and robust location test for most of the simulated scenarios except for very heavy tailed or heavy skewed data, and it is thus to be recommended except for these cases. The non-parametric adaptive tests were powerful for both normal and non-normal distributions under sample variance homogeneity. But when sample variances differed, they did not keep the type I error level. The parametric adaptive test lacks power for skewed and heavy tailed distributions.

  8. Evaluation of different jumping tests in defining position-specific and performance-level differences in high level basketball players

    Directory of Open Access Journals (Sweden)

    Miran Pehar

    2017-04-01

    Full Text Available The importance of jumping ability in basketball is well known, but there is an evident lack of studies that have examined different jumping testing protocols in basketball players at advanced levels. The aim of this study was to assess the applicability of different tests of jumping capacity in identifying differences between (i playing position and (ii competitive levels of professional players. Participants were 110 male professional basketball players (height: 194.92±8.09 cm; body mass: 89.33±10.91 kg; 21.58±3.92 years of age; Guards, 49; Forwards, 22; Centres, 39 who competed in the first (n = 58 and second division (n = 52. The variables included anthropometrics and jumping test performance. Jumping performances were evaluated by the standing broad jump (SBJ, countermovement jump (CMJ, reactive strength index (RSI, repeated reactive strength ability (RRSA and four running vertical jumps: maximal jump with (i take-off from the dominant leg and (ii non-dominant leg, lay-up shot jump with take-off from the (iii dominant leg and (iv non-dominant leg. First-division players were taller (ES: 0.76, 95%CI: 0.35-1.16, moderate differences, heavier (0.69, 0.29-1.10, had higher maximal reach height (0.67, 0.26-1.07, moderate differences, and had lower body fat % (-0.87, -1.27-0.45, moderate differences than second-division players. The playing positions differed significantly in three of four running jump achievements, RSI and RRSA, with Centres being least successful. The first-division players were superior to second-division players in SBJ (0.63, 0.23-1.03; 0.87, 0.26-1.43; 0.76, 0.11-1.63, all moderate differences, for total sample, Guards, and Forwards, respectively. Running vertical jumps and repeated jumping capacity can be used as valid measures of position-specific jumping ability in basketball. The differences between playing levels in vertical jumping achievement can be observed by assessing vertical jump scores together with differences

  9. Evaluation of different jumping tests in defining position-specific and performance-level differences in high level basketball players.

    Science.gov (United States)

    Pehar, Miran; Sekulic, Damir; Sisic, Nedim; Spasic, Miodrag; Uljevic, Ognjen; Krolo, Ante; Milanovic, Zoran; Sattler, Tine

    2017-09-01

    The importance of jumping ability in basketball is well known, but there is an evident lack of studies that have examined different jumping testing protocols in basketball players at advanced levels. The aim of this study was to assess the applicability of different tests of jumping capacity in identifying differences between (i) playing position and (ii) competitive levels of professional players. Participants were 110 male professional basketball players (height: 194.92±8.09 cm; body mass: 89.33±10.91 kg; 21.58±3.92 years of age; Guards, 49; Forwards, 22; Centres, 39) who competed in the first (n = 58) and second division (n = 52). The variables included anthropometrics and jumping test performance. Jumping performances were evaluated by the standing broad jump (SBJ), countermovement jump (CMJ), reactive strength index (RSI), repeated reactive strength ability (RRSA) and four running vertical jumps: maximal jump with (i) take-off from the dominant leg and (ii) non-dominant leg, lay-up shot jump with take-off from the (iii) dominant leg and (iv) non-dominant leg. First-division players were taller (ES: 0.76, 95%CI: 0.35-1.16, moderate differences), heavier (0.69, 0.29-1.10), had higher maximal reach height (0.67, 0.26-1.07, moderate differences), and had lower body fat % (-0.87, -1.27-0.45, moderate differences) than second-division players. The playing positions differed significantly in three of four running jump achievements, RSI and RRSA, with Centres being least successful. The first-division players were superior to second-division players in SBJ (0.63, 0.23-1.03; 0.87, 0.26-1.43; 0.76, 0.11-1.63, all moderate differences, for total sample, Guards, and Forwards, respectively). Running vertical jumps and repeated jumping capacity can be used as valid measures of position-specific jumping ability in basketball. The differences between playing levels in vertical jumping achievement can be observed by assessing vertical jump scores together with differences

  10. Helminths and skewed cytokine profiles increase tuberculin skin test positivity in Warao Amerindians

    NARCIS (Netherlands)

    Verhagen, L. M.; Hermans, P. W. M.; Warris, A.; de Groot, R.; Maes, M.; Villalba, J. A.; del Nogal, B.; van den Hof, S.; Mughini Gras, L.; van Soolingen, D.; Pinelli, E.; de Waard, J. H.

    2012-01-01

    The immune regulatory mechanisms involved in the acquisition of Mycobacterium tuberculosis infection in children are largely unknown. We investigated the influence of parasitic infections, malnutrition and plasma cytokine profiles on tuberculin skin test (TST) positivity in Warao Amerindians in

  11. Positive implicit attitudes toward odor words.

    Science.gov (United States)

    Bulsing, Patricia J; Smeets, Monique A M; van den Hout, Marcel A

    2007-07-01

    Associations between certain odors and for instance health effects may lead to positive or negative attitudes toward these odors. However, in experiments we conducted using the Implicit Association Test (IAT), we encountered attitudes even to odor "words." The IAT is based on the principle that reaction times measuring the association between words from a target dimension (in this case, odor vs. a neutral reference category) and an attribute dimension (i.e., positive or negative words) reflect the attitude to the target, where attitude-congruent associations between target and attribute are reflected by shorter reaction times. In a first experiment, we found distinctly positive attitudes to the concept odor in a student sample, which was replicated in a second experiment. In the main experiment, subjects in the aromatherapy group, who prefer using scented consumer products for relaxation purposes, showed a significantly more positive attitude toward odor words in the IAT than a control group, who did not have such a preference. The fact that results from the implicit test were not always associated with explicitly stated attitudes toward the odor words attests to the fact that the IAT measures the attitude of interest in a different way. As such, the IAT has added value in circumstances where explicit tests can be biased.

  12. Proposed optical test of Bell's inequalities not resting upon the fair sampling assumption

    International Nuclear Information System (INIS)

    Santos, Emilio

    2004-01-01

    Arguments are given against the fair sampling assumption, used to claim an empirical disproof of local realism. New tests are proposed, able to discriminate between quantum mechanics and a restricted, but appealing, family of local hidden-variables models. Such tests require detectors with efficiencies just above 20%

  13. Filtration and Leach Testing for PUREX Cladding Sludge and REDOX Cladding Sludge Actual Waste Sample Composites

    Energy Technology Data Exchange (ETDEWEB)

    Shimskey, Rick W.; Billing, Justin M.; Buck, Edgar C.; Casella, Amanda J.; Crum, Jarrod V.; Daniel, Richard C.; Draper, Kathryn E.; Edwards, Matthew K.; Hallen, Richard T.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Swoboda, Robert G.

    2009-03-02

    A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan (Barnes and Voke 2006). The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Hanford Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Under test plan TP RPP WTP 467 (Fiskum et al. 2007), eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. Under this test plan, a waste testing program was implemented that included: • Homogenizing the archive samples by group as defined in the test plan. • Characterizing the homogenized sample groups. • Performing parametric leaching testing on each group for compounds of interest. • Performing bench-top filtration/leaching tests in the hot cell for each group to simulate filtration and leaching activities if they occurred in the UFP2 vessel of the WTP Pretreatment Facility. This report focuses on a filtration/leaching test performed using two of the eight waste composite samples. The sample groups examined in this report were the plutonium-uranium extraction (PUREX) cladding waste sludge (Group 3, or CWP) and reduction-oxidation (REDOX) cladding waste sludge (Group 4, or CWR). Both the Group 3 and 4 waste composites were anticipated to be high in gibbsite, thus requiring caustic leaching. WTP RPT 167 (Snow et al. 2008) describes the homogenization, characterization, and parametric leaching activities before benchtop filtration/leaching testing of these two waste groups. Characterization and initial parametric data in that report were used to plan a single filtration/leaching test using a blend of both wastes. The test focused on filtration testing of the waste and caustic leaching for aluminum, in the form

  14. Evaluation of false positivity and cross reactivity in the investigation ...

    African Journals Online (AJOL)

    This study evaluated the causes of false positive Human Immunodeficiency Virus test results (F+HIV), cross reactivity of HIV antibodies with other non HIV antibodies, and efficiency of the serial and parallel testing algorithms. 100 blood samples randomly collected from clients attending the Heart to Heart HIV counseling and ...

  15. An Examination of Psychometric Properties of Positive Functional Attitudes Scale

    Directory of Open Access Journals (Sweden)

    Saide Umut ZEYBEK

    2017-08-01

    Full Text Available The aim of this study is to investigate the applicability of Coping Attitudes Scale: Measure of Positive Attitudes in Depression (CAS among Turkish young adult community sample and determine the psychometric properties (validity and reliability of this scale. This study was conducted with 419 students attending different departments in Mugla Sitki Kocman University, Faculty of Education in the spring semester of academic year of 2015-2016. Positive Functional Attitudes Scale, Beck Depression Scale, Beck Hopelessness Scale, Automatic Thoughts Scale, Positivity Scale and Developed Automatic Thoughts Scale.were used as data collection tools. Confirmatory factor analysis (CFA were used for investigation of the psychometric properties of the PFAS. Also, criterion-related validity, test-retest validity, and internal consistency were used calculated. The CFA results showed that standardized item estimates of the CAS ranged between 0.45 and 0.47. Also the CFA results showed that the original factor structure of the PFAS confirmed on the Turkish sample. internal consistency was calculated using the total community sample’s PFAS score. Cronbach’s alpha coefficient ort he total scale (.93 was high. Test-retest results of the subscales were 0.76. The findings showed that factor structures of the PFAS’ life perspective, personal accomplishment, positive future, self-worth, coping with problems had psychometric quality in Turkish version. As a result of the study, the Turkish version of PFAS has good validity and reliability for young adult community sample. [JCBPR 2017; 6(2.000: 59-66

  16. 9 CFR 146.13 - Testing.

    Science.gov (United States)

    2010-01-01

    ...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the... time reverse transcriptase/polymerase chain reaction (RRT-PCR) assay. (A) The RRT-PCR tests must be...

  17. Finish-Kazakhstan cooperation on an aerosols sampling - testing of a new methods for nuclear monitoring improvement

    International Nuclear Information System (INIS)

    Tarvajnen, M.; Akhmetov, M.A.; Ptitskaya, L.D.; Osintsev, A.Yu.; Zhantikin, T.M.; Eligbaeva, G.

    2001-01-01

    The aerosols sampling is the powerful method of air radioactivity monitoring both the natural and artificial origin. Up to the today the IAEA does not engage of aerosols sampling study. To study of possibility of this method examination for radiation monitoring - the state authorities of Finland and the Republic of Kazakhstan - Department of Radiation and Nuclear Safety (Stuck) and Kazakhstan Atomic Energy Committee - jointly carried out the field tests in Kazakhstan. The test was began in the Kurchatov in April 2000 - at the desire of IAEA working team on Iraq - close to former Semipalatinsk test site and was ended in Astana in August of 2001. The main aim of the field test was study of possibility and appropriateness of concept and technology of aerosols sampling developed for the complete condition of environment. In the paper the role of participating sides in the field test and main results and conclusions are discussed as well. The gained experience will allow developing the method aerosols sampling for IAEA international safeguard measures strengthening application

  18. The application of variable sampling method in the audit testing of insurance companies' premium income

    Directory of Open Access Journals (Sweden)

    Jovković Biljana

    2012-12-01

    Full Text Available The aim of this paper is to present the procedure of audit sampling using the variable sampling methods for conducting the tests of income from insurance premiums in insurance company 'Takovo'. Since the incomes from the insurance premiums from vehicle insurance and third-party vehicle insurance have the dominant share of the insurance company's income, the application of this method will be shown in the audit examination of these incomes - incomes from VI and TPVI premiums. For investigating the applicability of these methods in testing the income of other insurance companies, we shall implement the method of variable sampling in the audit testing of the premium income from the three leading insurance companies in Serbia, 'Dunav', 'DDOR' and 'Delta Generali' Insurance.

  19. Filaggrin compound heterozygous patients carry mutations in trans position

    DEFF Research Database (Denmark)

    Carlsen, Berit C; Meldgaard, Michael; Johansen, Jeanne D

    2013-01-01

    by means of allele-specific PCR amplification and analysis of PCR products by agarose gel electrophoresis. All R501X/2282del4 compound heterozygous samples collected over a 4-year period of routine FLG mutation testing were investigated. In total, 37 samples were tested. All thirty-seven R501X/2282del4......More than 40 null mutations in the filaggrin (FLG) gene are described. It is therefore possible to find two different null mutations in one individual (compound heterozygosity). It has been generally perceived that homozygous and compound heterozygous individuals were genotypically comparable......; however, this has not been scientifically investigated. Two different FLG null mutations in the same individual may be in trans position, meaning that each mutation locates to a different allele functionally equivalent to homozygosity, or may be in cis position, meaning that both mutations locate...

  20. Hydrodynamics during melting of an electroconductive sample in microgravity conditions under contactless positioning by electromagnetic forces

    Science.gov (United States)

    Korovin, V. M.

    MHD-flow during melting of a spherical metal sample under contactless positioning by alternating magnetic field produced by two circular turns with currents, is investigated. It is shown that when the currents supplying the turns are opposite in direction, electromagnetic forces, originating from the interaction of the Foucault currents with alternating magnetic field, induce two torus-like eddies in the interior of the molten metal drop.

  1. Evaluation of HIV counselling and testing, self-disclosure, social support and sexual behaviour change among a rural sample of HIV reactive patients in South Africa

    Directory of Open Access Journals (Sweden)

    E Sethosa

    2005-09-01

    Full Text Available The aim of this study was to evaluate HIV counselling and testing, self-disclosure, social support and sexual behavior change among HIV reactive patients among a rural sample of HIV reactive patients in South Africa. The sample consisted at the post-test counselling exit interview of 55 participants (41 women and 14 men who tested HIV-positive conveniently selected from a rural hospital and at five months follow-up at their homes 47. Results indicated that most patients had an HIV test because of medical reasons. At follow-up only 36% had disclosed their HIV status and half of the participants had had sex without condoms in the past three weeks. Major reason for not disclosing of their HIV status were being afraid of negative reactions, fear of discrimination, fear of violence, concerns about confidentiality and not yet ready. Social support was found to be significantly related to disclosure of HIV status, while counselling context and content and counselling satisfaction were not related with HIV disclosure.

  2. Acceptability of self-collected vaginal samples for HPV testing in an ...

    African Journals Online (AJOL)

    Objective: To evaluate the acceptability of self-collected vaginal samples for HPV testing in women living in rural and urban areas of Madagascar. Materials and methods: Participants were recruited in a health care center (urban group) and smaller affiliated dispensaries (rural group). They were invited to perform ...

  3. Test measurement of a new TESLA cavity beam position monitor at the ELBE linac

    International Nuclear Information System (INIS)

    Sargsyan, V.; Schreiber, H.J.; Evtushenko, P.; Schurig, R.

    2004-01-01

    A new type of a cavity BPM proposed for beam position determination along the TESLA linac was tested at the accelerator ELBE in Rossendorf / Dresden. Measurements using an improved BPM (large and stable cross-talk isolation, significantly less energy dissipation, a novel LO signal generation) were performed in single- and multi-bunch regimes. Agreement with expectations was found. The low bunch charge available allowed for preliminary measurements on sensitivity and position resolution, which extrapolated to TESLA would ful l the demands for precise bunch-to-bunch position determination. Possible improvements, in particular on the signal processing scheme, are also discussed. (orig.)

  4. Characterization, Leaching, and Filtration Testing for Tributyl Phosphate (TBP, Group 7) Actual Waste Sample Composites

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Matthew K.; Billing, Justin M.; Blanchard, David L.; Buck, Edgar C.; Casella, Amanda J.; Casella, Andrew M.; Crum, J. V.; Daniel, Richard C.; Draper, Kathryn E.; Fiskum, Sandra K.; Jagoda, Lynette K.; Jenson, Evan D.; Kozelisky, Anne E.; MacFarlan, Paul J.; Peterson, Reid A.; Shimskey, Rick W.; Snow, Lanee A.; Swoboda, Robert G.

    2009-03-09

    .A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual waste-testing program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. The tributyl phosphate sludge (TBP, Group 7) is the subject of this report. The Group 7 waste was anticipated to be high in phosphorus as well as aluminum in the form of gibbsite. Both are believed to exist in sufficient quantities in the Group 7 waste to address leaching behavior. Thus, the focus of the Group 7 testing was on the removal of both P and Al. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467.

  5. Power and Sample Size Calculations for Logistic Regression Tests for Differential Item Functioning

    Science.gov (United States)

    Li, Zhushan

    2014-01-01

    Logistic regression is a popular method for detecting uniform and nonuniform differential item functioning (DIF) effects. Theoretical formulas for the power and sample size calculations are derived for likelihood ratio tests and Wald tests based on the asymptotic distribution of the maximum likelihood estimators for the logistic regression model.…

  6. Sample Size Calculation for Estimating or Testing a Nonzero Squared Multiple Correlation Coefficient

    Science.gov (United States)

    Krishnamoorthy, K.; Xia, Yanping

    2008-01-01

    The problems of hypothesis testing and interval estimation of the squared multiple correlation coefficient of a multivariate normal distribution are considered. It is shown that available one-sided tests are uniformly most powerful, and the one-sided confidence intervals are uniformly most accurate. An exact method of calculating sample size to…

  7. Control of the positional relationship between a sample collection instrument and a surface to be analyzed during a sampling procedure using a laser sensor

    Science.gov (United States)

    Van Berkel, Gary J [Clinton, TN; Kertesz, Vilmos [Knoxville, TN

    2012-02-21

    A system and method utilizes distance-measuring equipment including a laser sensor for controlling the collection instrument-to-surface distance during a sample collection process for use, for example, with mass spectrometric detection. The laser sensor is arranged in a fixed positional relationship with the collection instrument, and a signal is generated by way of the laser sensor which corresponds to the actual distance between the laser sensor and the surface. The actual distance between the laser sensor and the surface is compared to a target distance between the laser sensor and the surface when the collection instrument is arranged at a desired distance from the surface for sample collecting purposes, and adjustments are made, if necessary, so that the actual distance approaches the target distance.

  8. Sample preparation of tank 241-C-106 grab samples and testing For compatibility with tank 241-AY-102 supernate

    International Nuclear Information System (INIS)

    Crawford, B.A.

    1996-01-01

    This test plan describes a sample separation method which will be used to obtain physical measurements and separated 241-C-106 solids and supernate fractions. In addition compatibility of tank 241-C-106 sludge with tank 241-AY-102 supernate will be determined

  9. Testing and testing positive: childhood adversities and later life HIV status among Kenyan women and their partners.

    Science.gov (United States)

    Goodman, Michael L; Raimer-Goodman, Lauren; Chen, Catherine X; Grouls, Astrid; Gitari, Stanley; Keiser, Philip H

    2017-12-01

    Adverse childhood experiences are a critical feature of lifelong health. No research assesses whether childhood adversities predict HIV-testing behaviors, and little research analyzes childhood adversities and later life HIV status in sub-Saharan Africa. We use regression models with cross-sectional data from a representative sample (n = 1974) to analyze whether adverse childhood experiences, separately or as cumulative exposures, predict reports of later life HIV testing and testing HIV+ among semi-rural Kenyan women and their partners. No significant correlation was observed between thirteen cumulative childhood adversities and reporting prior HIV testing for respondent or partner. Separately, childhood sexual abuse and emotional neglect predicted lower odds of reporting having previously been tested for HIV. Witnessing household violence during one's childhood predicted significantly higher odds of reporting HIV+. Sexual abuse predicted higher odds of reporting a partner tested HIV+. Preventing sexual abuse and household violence may improve HIV testing and test outcomes among Kenyan women. More research is required to understand pathways between adverse childhood experiences and partner selection within Kenya and sub-Saharan Africa, and data presented here suggest understanding pathways may help improve HIV outcomes. © The Author 2016. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Optical transmission testing based on asynchronous sampling techniques: images analysis containing chromatic dispersion using convolutional neural network

    Science.gov (United States)

    Mrozek, T.; Perlicki, K.; Tajmajer, T.; Wasilewski, P.

    2017-08-01

    The article presents an image analysis method, obtained from an asynchronous delay tap sampling (ADTS) technique, which is used for simultaneous monitoring of various impairments occurring in the physical layer of the optical network. The ADTS method enables the visualization of the optical signal in the form of characteristics (so called phase portraits) that change their shape under the influence of impairments such as chromatic dispersion, polarization mode dispersion and ASE noise. Using this method, a simulation model was built with OptSim 4.0. After the simulation study, data were obtained in the form of images that were further analyzed using the convolutional neural network algorithm. The main goal of the study was to train a convolutional neural network to recognize the selected impairment (distortion); then to test its accuracy and estimate the impairment for the selected set of test images. The input data consisted of processed binary images in the form of two-dimensional matrices, with the position of the pixel. This article focuses only on the analysis of images containing chromatic dispersion.

  11. Comparison of four microbiological inhibition tests for the screening of antimicrobial residues in the tissues of food-producing animals

    Directory of Open Access Journals (Sweden)

    Zuzana Gondová

    2014-10-01

    Full Text Available The study compares two existing microbiological inhibition tests, Screening Test for Antibiotic Residues (STAR and Premi®Test with two recently introduced tests, Nouws Antibiotic Test (NAT and Total Antibiotics for the screening of antimicrobial residues in the tissues of food-producing animals. In the negative or positive sample classification based on inhibition of the growth of test strain sensitive to many antibiotics and sulphonamides, out of 142 samples obtained from slaughterhouses and retail operations, 39 samples yielded a positive result in one or more tests: 4 samples in four tests, 14 samples in three tests, 13 samples in two tests, and 8 samples in one test. As for the numbers of observed positive samples, the descending sequence of tests was: STAR, Total Antibiotics, Premi®Test, NAT. The growth inhibition was observed in three out of seven test strains, namely Bacillus cereus ATCC 11778, Kocuria rhizophila ATCC 9341, and Bacillus stearothermophilus var. calidolactis. Considering the test strains sensitivity and no inhibition on the Bacillus pumilus NCIMB 10822 NAT test plates, our preliminary conclusion is that the animal samples are suspected for the presence of tetracycline, macrolide, and b-lactam antibiotics.

  12. Anodic electrode position of cyanometallates as sample preparation for the determination of transition metals from water samples using X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Wundt, K.; Duschner, H.; Starke, K.

    1978-01-01

    The anodic separation of cyanometallates of propanol -2/Water mixtures at high electrical field strengths was developed as new technique for sample preparation. The optimization of the parameters of the system (high voltage applied, current density, separation time and composition of the solution) resulted in quantitative precipitation of the metallates of Fe, Co, Ni, Cu, Zn, Cd and Ag in homogeneous, thin and strong-adhering layer with mass densities of between 1 nmol cm -2 and 1 μmol cm -2 on high-purity aluminium foils. Metals not forming anionic complexes remain in solution with simualtaneous quantitative multielement separation. The described technique is part of a method to determine heavy metal traces in water samples. It comprises the nonspecific sorption on cation exchangers, the elution of the transition metals as cyanometallates, their electrode position on aluminium foil and the determination by X-ray fluorescence analysis. Model experiments illustrate the possible applications of the method. (orig.) [de

  13. Mineralogic and petrologic investigation of pre-test core samples from the spent fuel test-climax

    International Nuclear Information System (INIS)

    Ryerson, F.J.; Qualheim, B.J.

    1983-12-01

    Pre-test samples obtained from just inside the perimeter of the canister emplacement holes of the Spent Fuel Test-Climax have been characterized by petrographic and microanalytical techniques. The primary quartz monzonite has undergone various degrees of hydrothermal alteration as a result of natural processes. Alteration is most apparent on primary plagioclase and biotite. The most common secondary phases on plagioclase are muscovite and calcite, while the most common secondary phases on biotite are epidote and chlorite. The major alteration zones encountered are localized along filled fractures, i.e. veins. The thickness and mineralogy of the alteration zones can be correlated with the vein mineralogy, becoming wider and more complex mineralogically when the veins contain calcite. 7 references, 10 figures, 4 tables

  14. Efficacy comparative of different laboratory test reagents for hepatitis C virus antibody

    Directory of Open Access Journals (Sweden)

    GUO Feibo

    2016-09-01

    Full Text Available Objective To investigate the effects of different laboratory test reagents for hepatitis C virus (HCV antibody through a comparative analysis. Methods A total of 207 samples which tested positive by four anti-HCV screening reagents commonly used in the laboratories in China (Kehua, Xinchuang, Wantai, and Abbott were included. HCV RNA nucleic acid amplification (NAT was performed, and if NAT results were negative, recombinant immunoblot assay (RIBA was performed for further confirmation. The test results of these four screening reagents were compared, and their S/CO values and true positive rates were analyzed. Results Of all the 205 samples testing positive by any one reagent, 191 (93.2% tested positive by the four reagents, and 14 (6.8% were tested inconsistently by the four reagents. The positive predictive values of Xinchuang, Kehua, Wantai, and Abbott reagents were 88.2% (180/204, 93.8% (180/192, 91.4% (180/197, and 90.0% (180/200, respectively. The S/CO thresholds with a positive predictive value of ≥95% for Xinchuang, Kehua, Wantai, and Abbott reagents were 9.0, 4.0, 5.0, and 7.0, respectively. Conclusion Xinchuang, Kehua, Wantai, and Abbott reagents have significantly different S/CO thresholds with a positive predictive value of ≥95%, which are significantly different from those in other domestic laboratories. Each laboratory should establish an applicable S/CO threshold with a positive predictive value of ≥95%, in order to reduce the sample size for confirmatory test.

  15. Seroprevalence of Epstein-Barr virus among HIV positive patients moreover and its association with CD4 positive lymphocyte count.

    Directory of Open Access Journals (Sweden)

    Alireza Abdollahi

    2014-12-01

    Full Text Available Opportunistic infections are the leading cause of hospitalization and morbidity in human immunodeficiency virus (HIV positive patients and are the most common cause of death between them. We aimed to measure IgG antibody against EBV viral capsid antigen (EBV-VCA IgG to determine the seroprevalence of this infection in HIV-positive population. A case-control study between September 2011 and October 2012 was conducted in a teaching hospital enrolling 114 HIV-positive patients as case group and 114 healthy individuals as control with similar age and sex. Enzyme-linked immunosurbant assay (ELISA technique was used for determination of EBV-VAC IgG in obtained samples. Of 114 serum samples obtained from HIV-positive patients, 103 (90.4% samples were found positive for EBV-VCA IgG antibody. There was no significant difference in seroprevalence of EBV VCA IgG antibody between patients received antiretroviral therapy and naive patients (91.5% vs. 87.5%, P>0.05. There was no statistically significant difference in EBV-VCA IgG seroprevalence between three groups of CD4+ in HIV positive group. In conclusion current study showed that seroprevalence of EBV in HIV-positive patients is higher than HIV-negative healthy participants; however, administration of HAART and CD4+ lymphocyte count did not reveal a significant effect in seroprevalence of EBV. Due to the significance of this virus in mortality and morbidity and causing certain malignancies in patients with AIDS, these patients are strongly recommended to be tested for this virus.

  16. Testing the entrepreneurial intention model on a two-country sample

    OpenAIRE

    Liñán, Francisco; Chen, Yi-Wen

    2006-01-01

    This paper tests the Entrepreneurial Intention Model -which is adapted from the Theory of Planned Behavior- on a sample of 533 individuals from two quite different countries: one of them European (Spain) and the other South Asian (Taiwan). A newly developed Entrepreneurial Intention Questionnaire (EIQ) has being used which tries to overcome some of the limitations of previous instruments. Structural equations techniques were used in the empirical analysis. Results are generally...

  17. Diagnostic Role of Head-Bending and Lying-Down Tests in Lateral Canal Benign Paroxysmal Positional Vertigo.

    Science.gov (United States)

    Yetiser, Sertac; Ince, Dilay

    2015-08-01

    To compare the diagnostic value of the head-bending test (HBT), lying-down positioning test (LDPT) and patient's report to identify the affected canal in video-nystagmographically (VNG) confirmed patients with lateral canal benign paroxysmal positional vertigo (LC-BPPV). Case series with chart review. Head-bending, lying-down positioning and the head-roll maneuver (HRM) under VNG guidance. The data were collected in a referral community hospital. Seventy-eight patients (32 apogeotropic and 46 geotropic nystagmus) with LC-BPPV who had been recruited between 2009 and 2013 were enrolled in the study. Patients were tested with the HRM and then were asked about subjectively worse side. Later, they were subjected to HBT when sitting and the LDPT. The results were compared and studied with the 1-way ANOVA and chi-square tests. Statistical significance was set at p < 0.05. Affected side was identified by HRM in 75% of patients with apogeotropic nystagmus and 95.6% of patients with geotropic nystagmus. Approximately 65.6% of patients with apogeotropic and 52% of patients with geotropic nystagmus had nystagmus during LDPT. However, its comparability with HRM was low. However, treatment plan based on LDPT results alone provided relief of symptoms in additional 12.5% of patients with apogeotropic and in 2.2% of patients with geotropic nystagmus. Approximately 63% of patients with apogeotropic and 56% of patients with geotropic nystagmus were able to tell the worse side. Nystagmus comparable with HRM during HBT was low and not diagnostic. HRM has the greatest diagnostic value of positioning tests in LC-BPPV in this study. LDPT provides some contribution in the diagnosis of LC-BPPV but much less than HRM. Patients' subjective feeling of vertigo was also a useful test. However, HBT was not as sensitive as other measures in uncertain cases.

  18. Impact of relative position vehicle-wind blower in a roller test bench under climatic chamber

    International Nuclear Information System (INIS)

    Fernández-Yáñez, P.; Armas, O.; Martínez-Martínez, S.

    2016-01-01

    Highlights: • Air simulation model was developed for a vehicle test bench under climatic chamber. • Good accuracy between experimental data and simulated values were obtained. • Wind blower-vehicle relative position alters external cooling of after-treatment devices. • Vehicle emission certification can be affected by wind blower-vehicle relative position. - Abstract: In terms of energy efficiency and exhaust emissions control, an appropriate design of cooling systems of climatic chambers destined to vehicle certification and/or perform scientific research is becoming increasingly important. European vehicle emissions certification (New European Driving Cycle, NEDC) establishes the position of the wind-simulation blower at 200 mm above floor level. This height is fixed and kept constant independently of the vehicle tested. The position of the blower with respect to the vehicle can modify the external forced convection under the car, where after-treatment devices are located. Consequently, the performance of such devices could be modified and emission results during the certification cycle could be non-representative of real-world driving conditions. The aim of this work is to study the influence of different wind blower-vehicle relative heights on the air velocity and temperature profiles under the car by means of a simple computational fluid dynamics (CFD) approach. A steady state three-dimensional CFD model was developed and applied to the estimation of the air velocity and temperature profiles inside of a climatic chamber equipped with a vehicle roller (chassis dyno) test bench. The simulations reproduce one steady-state condition from NEDC, specifically the EU17 mode (120 km/h, maximum velocity during the cycle). The cool air propelling temperature was 20 °C (minimum temperature in the NEDC range). Simulations were performed employing the Reynolds-Averaged Navier-Stokes (RANS) approach with the realizable k-ε model to provide closure. Air velocity and

  19. [An attempt to construct a Japanese version of the Implicit Positive and Negative Affect Test (IPANAT)].

    Science.gov (United States)

    Shimoda, Shunsuke; Okubo, Nobutoshi; Kobayashi, Mai; Sato, Shigetaka; Kitamura, Hideya

    2014-08-01

    The Implicit Positive and Negative Affect Test (IPANAT) is an instrument for the indirect assessment of positive and negative affect. A Japanese version of the IPANAT was developed and its reliability and validity were examined. In Study 1, factor analysis identified two independent factors that could be interpreted as implicit positive and negative affect, which corresponded to the original version. The Japanese IPANAT also had sufficient internal consistency and acceptable test-retest reliability. In Study 2, we demonstrated that the Japanese IPANAT was associated with explicit state affect (e.g., PANAS), extraversion, and neuroticism, which indicated its adequate construct validity. In Study 3, we examined the extent to which the Japanese IPANAT was sensitive to changes in affect by assessing a set of IPANAT items after the presentation of positive, negative, or neutral photographs. The results indicated that the Japanese IPANAT was sufficiently sensitive to changes in affect resulting from affective stimuli. Taken together, these studies suggest that the Japanese version of the IPANAT is a useful instrument for the indirect assessment of positive and negative affect.

  20. On the High-dimensional Power of Linear-time Kernel Two-Sample Testing under Mean-difference Alternatives

    OpenAIRE

    Ramdas, Aaditya; Reddi, Sashank J.; Poczos, Barnabas; Singh, Aarti; Wasserman, Larry

    2014-01-01

    Nonparametric two sample testing deals with the question of consistently deciding if two distributions are different, given samples from both, without making any parametric assumptions about the form of the distributions. The current literature is split into two kinds of tests - those which are consistent without any assumptions about how the distributions may differ (\\textit{general} alternatives), and those which are designed to specifically test easier alternatives, like a difference in me...

  1. Reduced detection by Ziehl-Neelsen method of acid-fast bacilli in sputum samples preserved in cetylpyridinium chloride solution.

    Science.gov (United States)

    Selvakumar, N; Sudhamathi, S; Duraipandian, M; Frieden, T R; Narayanan, P R

    2004-02-01

    Twelve health facilities implementing the DOTS strategy, and the Tuberculosis Research Centre (TRC), Chennai, India. To determine the detection rates using Ziehl-Neelsen (ZN) and auramine-phenol to stain acid-fast bacilli (AFB) in sputum samples stored in cetylpyridinium chloride (CPC) solution. Two smears were prepared from each of 988 sputum samples collected in CPC and randomly allocated, one to ZN and the other to auramine-phenol staining. All samples were processed for culture of Mycobacterium tuberculosis. A significantly higher proportion of samples were negative using the ZN method compared to the auramine-phenol method (74.5% vs. 61.8%, McNamara's paired chi2 test; P < 0.001). Among 377 samples that were positive using auramine-phenol, 44% were negative using ZN. There were more culture-positive, smear-negative samples in ZN (52.7%) than in auramine-phenol (30%); the difference attained statistical significance (McNemar's paired chi2 test; P < 0.00004). Using ZN, of the 104 smears made immediately after collection, 52 were positive for AFB, of which only 35 (67.3%) were positive after storage in CPC; the reduction in the number of positive smears attained statistical significance (McNemar's paired chi2 test; P = 0.004). Detection of AFB in sputum samples preserved in CPC is significantly reduced using ZN staining.

  2. A note on Poisson goodness-of-fit tests for ionizing radiation induced chromosomal aberration samples.

    Science.gov (United States)

    Higueras, Manuel; González, J E; Di Giorgio, Marina; Barquinero, J F

    2018-05-18

    To present Poisson exact goodness-of-fit tests as alternatives and complements to the asymptotic u-test, which is the most widely used in cytogenetic biodosimetry, to decide whether a sample of chromosomal aberrations in blood cells comes from an homogeneous or inhomogeneous exposure. Three Poisson exact goodness-of-fit test from the literature are introduced and implemented in the R environment. A Shiny R Studio application, named GOF Poisson, has been updated for the purpose of giving support to this work. The three exact tests and the u-test are applied in chromosomal aberration data from clinical and accidental radiation exposure patients. It is observed how the u-test is not an appropriate approximation in small samples with small yield of chromosomal aberrations. Tools are provided to compute the three exact tests, which is not as trivial as the implementation of the u-test. Poisson exact goodness-of-fit tests should be considered jointly to the u-test for detecting inhomogeneous exposures in the cytogenetic biodosimetry practice.

  3. Basic distribution free identification tests for small size samples of environmental data

    International Nuclear Information System (INIS)

    Federico, A.G.; Musmeci, F.

    1998-01-01

    Testing two or more data sets for the hypothesis that they are sampled form the same population is often required in environmental data analysis. Typically the available samples have a small number of data and often then assumption of normal distributions is not realistic. On the other hand the diffusion of the days powerful Personal Computers opens new possible opportunities based on a massive use of the CPU resources. The paper reviews the problem introducing the feasibility of two non parametric approaches based on intrinsic equi probability properties of the data samples. The first one is based on a full re sampling while the second is based on a bootstrap approach. A easy to use program is presented. A case study is given based on the Chernobyl children contamination data [it

  4. 10 CFR Appendix B to Subpart K of... - Sampling Plan for Enforcement Testing

    Science.gov (United States)

    2010-01-01

    ... yields a 97.5 percent confidence level for a one-tailed t-test. Step 7. Compare the mean of the first sample (X 1) with the lower control limit (LCL1) to determine one of the following: (i) If the mean of... from Step 5. Compare the combined sample mean (X 2) to the lower control limit (LCL2) to find one of...

  5. Digitally Available Interval-Specific Rock-Sample Data Compiled from Historical Records, Nevada Test Site and Vicinity, Nye County, Nevada.

    Energy Technology Data Exchange (ETDEWEB)

    David B. Wood

    2007-10-24

    Between 1951 and 1992, 828 underground tests were conducted on the Nevada Test Site, Nye County, Nevada. Prior to and following these nuclear tests, holes were drilled and mined to collect rock samples. These samples are organized and stored by depth of borehole or drift at the U.S. Geological Survey Core Library and Data Center at Mercury, Nevada, on the Nevada Test Site. From these rock samples, rock properties were analyzed and interpreted and compiled into project files and in published reports that are maintained at the Core Library and at the U.S. Geological Survey office in Henderson, Nevada. These rock-sample data include lithologic descriptions, physical and mechanical properties, and fracture characteristics. Hydraulic properties also were compiled from holes completed in the water table. Rock samples are irreplaceable because pre-test, in-place conditions cannot be recreated and samples cannot be recollected from the many holes destroyed by testing. Documenting these data in a published report will ensure availability for future investigators.

  6. A comparison of temporal and location-based sampling strategies for global positioning system-triggered electronic diaries.

    Science.gov (United States)

    Törnros, Tobias; Dorn, Helen; Reichert, Markus; Ebner-Priemer, Ulrich; Salize, Hans-Joachim; Tost, Heike; Meyer-Lindenberg, Andreas; Zipf, Alexander

    2016-11-21

    Self-reporting is a well-established approach within the medical and psychological sciences. In order to avoid recall bias, i.e. past events being remembered inaccurately, the reports can be filled out on a smartphone in real-time and in the natural environment. This is often referred to as ambulatory assessment and the reports are usually triggered at regular time intervals. With this sampling scheme, however, rare events (e.g. a visit to a park or recreation area) are likely to be missed. When addressing the correlation between mood and the environment, it may therefore be beneficial to include participant locations within the ambulatory assessment sampling scheme. Based on the geographical coordinates, the database query system then decides if a self-report should be triggered or not. We simulated four different ambulatory assessment sampling schemes based on movement data (coordinates by minute) from 143 voluntary participants tracked for seven consecutive days. Two location-based sampling schemes incorporating the environmental characteristics (land use and population density) at each participant's location were introduced and compared to a time-based sampling scheme triggering a report on the hour as well as to a sampling scheme incorporating physical activity. We show that location-based sampling schemes trigger a report less often, but we obtain more unique trigger positions and a greater spatial spread in comparison to sampling strategies based on time and distance. Additionally, the location-based methods trigger significantly more often at rarely visited types of land use and less often outside the study region where no underlying environmental data are available.

  7. 76 FR 69585 - Testing and Labeling Pertaining to Product Certification Regarding Representative Samples for...

    Science.gov (United States)

    2011-11-08

    ... 1107 Testing and Labeling Pertaining to Product Certification Regarding Representative Samples for... [CPSC Docket No. CPSC-2011-0082] Testing and Labeling Pertaining to Product Certification Regarding... to Product Certification.'' The proposed rule was intended to implement what was then known as...

  8. Reporting altered test results in hemolyzed samples: is the cure worse than the disease?

    Science.gov (United States)

    Lippi, Giuseppe; Cervellin, Gianfranco; Plebani, Mario

    2017-07-26

    The management of laboratory data in unsuitable (hemolyzed) samples remains an almost unresolved dilemma. Whether or not laboratory test results obtained by measuring unsuitable specimens should be made available to the clinicians has been the matter of fierce debates over the past decades. Recently, an intriguing alternative to suppressing test results and recollecting the specimen has been put forward, entailing the definition and implementation of specific algorithms that would finally allow reporting a preanalytically altered laboratory value within a specific comment about its uncertainty of measurement. This approach carries some advantages, namely the timely communication of potentially life-threatening laboratory values, but also some drawbacks. These especially include the challenging definition of validated performance specifications for hemolyzed samples, the need to producing reliable data with the lowest possible uncertainty, the short turnaround time for repeating most laboratory tests, the risk that the comments may be overlooked in short-stay and frequently overcrowded units (e.g. the emergency department), as well as the many clinical advantages of a direct communication with the physician in charge of the patient. Despite the debate remains open, we continue supporting the suggestion that suppressing data in unsuitable (hemolyzed) samples and promptly notifying the clinicians about the need to recollect the samples remains the most (clinically and analytically) safe practice.

  9. Amphetamines and cannabinoids testing in hair: Evaluation of results from a two-year period.

    Science.gov (United States)

    Burgueño, María José; Alonso, Amaya; Sánchez, Sergio

    2016-08-01

    This paper presents an overview of a set of amphetamines and cannabinoids tests performed on head hair samples from the Medico-Legal sector at the Madrid Department of the Spanish National Institute of Toxicology and Forensic Sciences during the years 2013 and 2014. The hair samples were tested for five stimulant phenylalkylamine derivatives -amphetamine (AP), methamphetamine (MA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxy-amphetamine (MDA), and 3,4-methylenedioxy-N-ethylamphetamine (MDEA)- and/or two cannabinoids-Δ(9)-tetrahydrocannabinol (THC) and cannabinol (CBN)- by gas chromatography equipped with mass spectrometry detection in selected-ion monitoring mode, applying a method accredited to ISO/IEC 17025 standards. The test results were interpreted according to the confirmation cut-offs proposed by the Society of Hair Testing (SoHT) to identify chronic drug use. The ratios of positive results were studied in relation to gender, age, hair colour, dyeing and length of the tested samples to assess the independence from these variables or the association with them. Low, medium and high ranges of concentration were also estimated for each drug. 21.94% of the 2954 hair samples tested for phenylalkylamine derivatives were positive for one or more substances. 16.38% of the samples were positive for AP, 12.09% for MDMA and only 0.44% for MA. 6.60% of the tested samples were positive for AP/MDMA combination. A total of 3178 samples were tested for cannabinoids, resulting in 53.40% positive for THC and CBN. Simultaneous tests for phenylalkylamine derivatives and cannabinoids were performed in 2931 of the samples; 14.94% of them were positive for THC, CBN, and one or more amphetamines. According to the results from the statistical analysis, the use of THC and MDMA vary with age and gender among the Medico-Legal sector in an extended area of Spain, while the use of AP appears to be independent of these variables. On the other hand, the results of THC in

  10. Beam position determination for the Test Storage Ring

    International Nuclear Information System (INIS)

    Baumann, P.

    1987-01-01

    The Test Storage Ring (TSR) for heavy ions, currently under design and construction at the Max Planck Institute for Nuclear Physics in Heidelberg, requires an extensive beam diagnostics system in order to enable it to operate without friction. This thesis concerns the beam position determination sub-system of this diagnostics system which is intended to determine the beam center of gravity of a bunched beam inside the cross section of the beam tube in a non-destructive manner. An electrostatic pickup is used to sense the location of the beam; the mode of operation of this device will be explained in detail. The signals go to a preamplifier from where they are then sent via a multiplex system to the measuring unit. This point also represents the interface to the computer system that controls the TSR. The prototype developed here was tested with the aid of a particle beam, as well as with other measurement methods. Resolutions of better than 1 mm about the center have been measured. In order to achieve or even improve such resolutions later in actual operation, it is possible to determine the properties of the preamplifiers with the aid of calibration signals and to take these into account in the course of the signal evaluation in the computer. The differences between the individual electrodes of a given pickup must also be compensated. These procedures and their associated electronic circuits are also described in this paper

  11. Positive body image: inter-ethnic and rural-urban differences among an indigenous sample from Malaysian Borneo.

    Science.gov (United States)

    Swami, Viren; Kannan, Kumaraswami; Furnham, Adrian

    2012-11-01

    Previous studies examining body image from a cross-cultural perspective have tended to neglect samples from different ethnic groups or along a rural-urban continuum. To overcome this limitation, the present study examined positive body image among rural and urban women from three major indigenous ethnic groups in Sabah, Malaysia. A total of 202 women completed the Body Appreciation Scale, as well as measures of media exposure and financial security, and provided their demographic details. s showed that there were significant rural-urban differences in body appreciation, with rural participants having significantly higher body appreciation than urban participants. A comparison with a previous data set of West Malaysian women (Swami & Chamorro-Premuzic, 2008) showed that the current urban sample had significantly lower body appreciation and that the rural group had significantly higher body appreciation. Further results showed that research site (urban vs rural) explained 11.0% of the variance in body appreciation. Participant body mass index and exposure to western forms of media explained an additional 2.0% of the variance. These results suggest that there are differences in body image between rural and urban women. Results are discussed in relation to the promotion of positive body image, particularly in developing societies where health care resources may be limited.

  12. 10 CFR Appendix A to Subpart U of... - Sampling Plan for Enforcement Testing of Electric Motors

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Sampling Plan for Enforcement Testing of Electric Motors A Appendix A to Subpart U of Part 431 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY... to Subpart U of Part 431—Sampling Plan for Enforcement Testing of Electric Motors Step 1. The first...

  13. Non-invasive prenatal testing for trisomies 21, 18 and 13

    DEFF Research Database (Denmark)

    Zhang, H.; Gao, Y.; Jiang, F.

    2015-01-01

    OBJECTIVES: To report the clinical performance of massively parallel sequencing-based non-invasive prenatal testing (NIPT) in detecting trisomies 21, 18 and 13 in over 140 000 clinical samples and to compare its performance in low-risk and high-risk pregnancies. METHODS: Between 1 January 2012...... samples, for which outcome data were available in 112 669 (76.7%). Repeat blood sampling was required in 3213 cases and 145 had test failure. Aneuploidy was confirmed in 720/781 cases positive for trisomy 21, 167/218 cases positive for trisomy 18 and 22/67 cases positive for trisomy 13 on NIPT. Nine false...... difference in test performance between the 72 382 high-risk and 40 287 low-risk subjects (sensitivity, 99.21% vs 98.97% (P = 0.82); specificity, 99.95% vs 99.95% (P = 0.98)). The major factors contributing to false-positive and false-negative NIPT results were maternal copy number variant and fetal...

  14. Testing the entrepreneurial intention model on a two-country sample

    OpenAIRE

    Liñán, Francisco

    2006-01-01

    This paper tests the Entrepreneurial Intention Model -which is adapted from the Theory of Planned Behavior- on a sample of 533 individuals from two quite different countries: one of them European (Spain) and the other South Asian (Taiwan). A newly developed Entrepreneurial Intention Questionnaire (EIQ) has being used which tries to overcome some of the limitations of previous instruments. Structural equations techniques were used in the empirical analysis. Results are generally satisfactory, ...

  15. Cone penetrometer tests and HydroPunch sampling: A screening technique for plume definition

    International Nuclear Information System (INIS)

    Smolley, M.; Kappmeyer, J.C.

    1991-01-01

    Cone penetrometer tests and HydroPunch sampling were used to define the extent of volatile organic compounds in ground water. The investigation indicated that the combination of the these techniques is effective for obtaining ground water samples for preliminary plume definition. HydroPunch samples can be collected in unconsolidated sediments and the analytical results obtained from these samples are comparable to those obtained from adjacent monitoring wells. This sampling method is a rapid and cost-effective screening technique for characterizing the extent of contaminant plumes in soft sediment environments. Use of this screening technique allowed monitoring wells to be located at the plume boundary, thereby reducing the number of wells installed and the overall cost of the plume definition program

  16. Feasibility tests of a high resolution sampling radial drift chamber

    International Nuclear Information System (INIS)

    Huth, J.

    1985-01-01

    The design concept and results of feasibility tests for a vertex detector intended for use in the TPC-PEP4/9 experiment are presented. The detector is based on a slow radial drift in dimethyl ether. High resolution localization of the avalanches at the sense wire is accomplished with nearby pickup wires and the utilization of waveform sampling electronics. The avalanche angular coordinate measurements, combined with knowledge of the electric field distribution and drift velocity permit reconstruction of the trajectory using essentially all track information. Measurements with a test chamber constructed to study characteristics of avalanche localization indicate that the recoverable track information in one centimeter of dimethyl ether at 1.5 atm is equivalent to 30 measurements of 40 μm accuracy. (orig.)

  17. Testing Theoretical Relationships: Factors Influencing Positive Health Practices (PHP) in Filipino College Students

    Science.gov (United States)

    Ayres, Cynthia; Mahat, Ganga; Atkins, Robert

    2013-01-01

    Objective: To examine variables influencing the positive health practices (PHP) of Filipino college students to gain a better understanding of health practices in this ethnic/racial group. Cross-sectional study tested theoretical relationships postulated among (a) PHP, (b) social support (SS), (c) optimism, and (d) acculturation. Participants: A…

  18. Controlled chloride cracking of austenitic stainless steel tube samples

    OpenAIRE

    Raseroka, M.S.; Pistorius, P.C.

    2009-01-01

    An experimental rig has been constructed to produce chloride stress corrosion cracks in Type 304L stainless steel tube samples. The samples are to be used to test possible in situ repair methods in future work. The factor which influences the time to failure most strongly is the sample temperature; the distribution of cracks within the sample is affected by local temperature variations and by the position of the water line. Low-frequency oscillations in stress, caused by the on-off temperatur...

  19. Critical tests for determination of microbiological quality and biological activity in commercial vermicompost samples of different origins.

    Science.gov (United States)

    Grantina-Ievina, Lelde; Andersone, Una; Berkolde-Pīre, Dace; Nikolajeva, Vizma; Ievinsh, Gederts

    2013-12-01

    The aim of the present paper was to show that differences in biological activity among commercially produced vermicompost samples can be found by using a relatively simple test system consisting of microorganism tests on six microbiological media and soilless seedling growth tests with four vegetable crop species. Significant differences in biological properties among analyzed samples were evident both at the level of microbial load as well as plant growth-affecting activity. These differences were mostly manufacturer- and feedstock-associated, but also resulted from storage conditions of vermicompost samples. A mature vermicompost sample that was produced from sewage sludge still contained considerable number of Escherichia coli. Samples from all producers contained several potentially pathogenic fungal species such as Aspergillus fumigatus, Pseudallescheria boidii, Pseudallescheria fimeti, Pseudallescheria minutispora, Scedosporium apiospermum, Scedosporium prolificans, Scopulariopsis brevicaulis, Stachybotrys chartarum, Geotrichum spp., Aphanoascus terreus, and Doratomyces columnaris. In addition, samples from all producers contained plant growth-promoting fungi from the genera Trichoderma and Mortierella. The described system can be useful both for functional studies aiming at understanding of factors affecting quality characteristics of vermicompost preparations and for routine testing of microbiological quality and biological activity of organic waste-derived composts and vermicomposts.

  20. Pigeons exhibit higher accuracy for chosen memory tests than for forced memory tests in duration matching-to-sample.

    Science.gov (United States)

    Adams, Allison; Santi, Angelo

    2011-03-01

    Following training to match 2- and 8-sec durations of feederlight to red and green comparisons with a 0-sec baseline delay, pigeons were allowed to choose to take a memory test or to escape the memory test. The effects of sample omission, increases in retention interval, and variation in trial spacing on selection of the escape option and accuracy were studied. During initial testing, escaping the test did not increase as the task became more difficult, and there was no difference in accuracy between chosen and forced memory tests. However, with extended training, accuracy for chosen tests was significantly greater than for forced tests. In addition, two pigeons exhibited higher accuracy on chosen tests than on forced tests at the short retention interval and greater escape rates at the long retention interval. These results have not been obtained in previous studies with pigeons when the choice to take the test or to escape the test is given before test stimuli are presented. It appears that task-specific methodological factors may determine whether a particular species will exhibit the two behavioral effects that were initially proposed as potentially indicative of metacognition.