WorldWideScience

Sample records for sample size computations

  1. Computing Confidence Bounds for Power and Sample Size of the General Linear Univariate Model

    OpenAIRE

    Taylor, Douglas J.; Muller, Keith E.

    1995-01-01

    The power of a test, the probability of rejecting the null hypothesis in favor of an alternative, may be computed using estimates of one or more distributional parameters. Statisticians frequently fix mean values and calculate power or sample size using a variance estimate from an existing study. Hence computed power becomes a random variable for a fixed sample size. Likewise, the sample size necessary to achieve a fixed power varies randomly. Standard statistical practice requires reporting ...

  2. Speeding Up Non-Parametric Bootstrap Computations for Statistics Based on Sample Moments in Small/Moderate Sample Size Applications.

    Directory of Open Access Journals (Sweden)

    Elias Chaibub Neto

    Full Text Available In this paper we propose a vectorized implementation of the non-parametric bootstrap for statistics based on sample moments. Basically, we adopt the multinomial sampling formulation of the non-parametric bootstrap, and compute bootstrap replications of sample moment statistics by simply weighting the observed data according to multinomial counts instead of evaluating the statistic on a resampled version of the observed data. Using this formulation we can generate a matrix of bootstrap weights and compute the entire vector of bootstrap replications with a few matrix multiplications. Vectorization is particularly important for matrix-oriented programming languages such as R, where matrix/vector calculations tend to be faster than scalar operations implemented in a loop. We illustrate the application of the vectorized implementation in real and simulated data sets, when bootstrapping Pearson's sample correlation coefficient, and compared its performance against two state-of-the-art R implementations of the non-parametric bootstrap, as well as a straightforward one based on a for loop. Our investigations spanned varying sample sizes and number of bootstrap replications. The vectorized bootstrap compared favorably against the state-of-the-art implementations in all cases tested, and was remarkably/considerably faster for small/moderate sample sizes. The same results were observed in the comparison with the straightforward implementation, except for large sample sizes, where the vectorized bootstrap was slightly slower than the straightforward implementation due to increased time expenditures in the generation of weight matrices via multinomial sampling.

  3. Inferring Population Size History from Large Samples of Genome-Wide Molecular Data - An Approximate Bayesian Computation Approach.

    Directory of Open Access Journals (Sweden)

    Simon Boitard

    2016-03-01

    Full Text Available Inferring the ancestral dynamics of effective population size is a long-standing question in population genetics, which can now be tackled much more accurately thanks to the massive genomic data available in many species. Several promising methods that take advantage of whole-genome sequences have been recently developed in this context. However, they can only be applied to rather small samples, which limits their ability to estimate recent population size history. Besides, they can be very sensitive to sequencing or phasing errors. Here we introduce a new approximate Bayesian computation approach named PopSizeABC that allows estimating the evolution of the effective population size through time, using a large sample of complete genomes. This sample is summarized using the folded allele frequency spectrum and the average zygotic linkage disequilibrium at different bins of physical distance, two classes of statistics that are widely used in population genetics and can be easily computed from unphased and unpolarized SNP data. Our approach provides accurate estimations of past population sizes, from the very first generations before present back to the expected time to the most recent common ancestor of the sample, as shown by simulations under a wide range of demographic scenarios. When applied to samples of 15 or 25 complete genomes in four cattle breeds (Angus, Fleckvieh, Holstein and Jersey, PopSizeABC revealed a series of population declines, related to historical events such as domestication or modern breed creation. We further highlight that our approach is robust to sequencing errors, provided summary statistics are computed from SNPs with common alleles.

  4. Sample size calculations for case-control studies

    Science.gov (United States)

    This R package can be used to calculate the required samples size for unconditional multivariate analyses of unmatched case-control studies. The sample sizes are for a scalar exposure effect, such as binary, ordinal or continuous exposures. The sample sizes can also be computed for scalar interaction effects. The analyses account for the effects of potential confounder variables that are also included in the multivariate logistic model.

  5. Improved sample size determination for attributes and variables sampling

    International Nuclear Information System (INIS)

    Stirpe, D.; Picard, R.R.

    1985-01-01

    Earlier INMM papers have addressed the attributes/variables problem and, under conservative/limiting approximations, have reported analytical solutions for the attributes and variables sample sizes. Through computer simulation of this problem, we have calculated attributes and variables sample sizes as a function of falsification, measurement uncertainties, and required detection probability without using approximations. Using realistic assumptions for uncertainty parameters of measurement, the simulation results support the conclusions: (1) previously used conservative approximations can be expensive because they lead to larger sample sizes than needed; and (2) the optimal verification strategy, as well as the falsification strategy, are highly dependent on the underlying uncertainty parameters of the measurement instruments. 1 ref., 3 figs

  6. Sample size computation for association studies using case–parents ...

    Indian Academy of Sciences (India)

    ple size needed to reach a given power (Knapp 1999; Schaid. 1999; Chen and Deng 2001; Brown 2004). In their seminal paper, Risch and Merikangas (1996) showed that for a mul- tiplicative mode of inheritance (MOI) for the susceptibility gene, sample size depends on two parameters: the frequency of the risk allele at the ...

  7. Sample size methodology

    CERN Document Server

    Desu, M M

    2012-01-01

    One of the most important problems in designing an experiment or a survey is sample size determination and this book presents the currently available methodology. It includes both random sampling from standard probability distributions and from finite populations. Also discussed is sample size determination for estimating parameters in a Bayesian setting by considering the posterior distribution of the parameter and specifying the necessary requirements. The determination of the sample size is considered for ranking and selection problems as well as for the design of clinical trials. Appropria

  8. Sample size determination for mediation analysis of longitudinal data.

    Science.gov (United States)

    Pan, Haitao; Liu, Suyu; Miao, Danmin; Yuan, Ying

    2018-03-27

    Sample size planning for longitudinal data is crucial when designing mediation studies because sufficient statistical power is not only required in grant applications and peer-reviewed publications, but is essential to reliable research results. However, sample size determination is not straightforward for mediation analysis of longitudinal design. To facilitate planning the sample size for longitudinal mediation studies with a multilevel mediation model, this article provides the sample size required to achieve 80% power by simulations under various sizes of the mediation effect, within-subject correlations and numbers of repeated measures. The sample size calculation is based on three commonly used mediation tests: Sobel's method, distribution of product method and the bootstrap method. Among the three methods of testing the mediation effects, Sobel's method required the largest sample size to achieve 80% power. Bootstrapping and the distribution of the product method performed similarly and were more powerful than Sobel's method, as reflected by the relatively smaller sample sizes. For all three methods, the sample size required to achieve 80% power depended on the value of the ICC (i.e., within-subject correlation). A larger value of ICC typically required a larger sample size to achieve 80% power. Simulation results also illustrated the advantage of the longitudinal study design. The sample size tables for most encountered scenarios in practice have also been published for convenient use. Extensive simulations study showed that the distribution of the product method and bootstrapping method have superior performance to the Sobel's method, but the product method was recommended to use in practice in terms of less computation time load compared to the bootstrapping method. A R package has been developed for the product method of sample size determination in mediation longitudinal study design.

  9. CT dose survey in adults: what sample size for what precision?

    International Nuclear Information System (INIS)

    Taylor, Stephen; Muylem, Alain van; Howarth, Nigel; Gevenois, Pierre Alain; Tack, Denis

    2017-01-01

    To determine variability of volume computed tomographic dose index (CTDIvol) and dose-length product (DLP) data, and propose a minimum sample size to achieve an expected precision. CTDIvol and DLP values of 19,875 consecutive CT acquisitions of abdomen (7268), thorax (3805), lumbar spine (3161), cervical spine (1515) and head (4106) were collected in two centers. Their variabilities were investigated according to sample size (10 to 1000 acquisitions) and patient body weight categories (no weight selection, 67-73 kg and 60-80 kg). The 95 % confidence interval in percentage of their median (CI95/med) value was calculated for increasing sample sizes. We deduced the sample size that set a 95 % CI lower than 10 % of the median (CI95/med ≤ 10 %). Sample size ensuring CI95/med ≤ 10 %, ranged from 15 to 900 depending on the body region and the dose descriptor considered. In sample sizes recommended by regulatory authorities (i.e., from 10-20 patients), mean CTDIvol and DLP of one sample ranged from 0.50 to 2.00 times its actual value extracted from 2000 samples. The sampling error in CTDIvol and DLP means is high in dose surveys based on small samples of patients. Sample size should be increased at least tenfold to decrease this variability. (orig.)

  10. CT dose survey in adults: what sample size for what precision?

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Stephen [Hopital Ambroise Pare, Department of Radiology, Mons (Belgium); Muylem, Alain van [Hopital Erasme, Department of Pneumology, Brussels (Belgium); Howarth, Nigel [Clinique des Grangettes, Department of Radiology, Chene-Bougeries (Switzerland); Gevenois, Pierre Alain [Hopital Erasme, Department of Radiology, Brussels (Belgium); Tack, Denis [EpiCURA, Clinique Louis Caty, Department of Radiology, Baudour (Belgium)

    2017-01-15

    To determine variability of volume computed tomographic dose index (CTDIvol) and dose-length product (DLP) data, and propose a minimum sample size to achieve an expected precision. CTDIvol and DLP values of 19,875 consecutive CT acquisitions of abdomen (7268), thorax (3805), lumbar spine (3161), cervical spine (1515) and head (4106) were collected in two centers. Their variabilities were investigated according to sample size (10 to 1000 acquisitions) and patient body weight categories (no weight selection, 67-73 kg and 60-80 kg). The 95 % confidence interval in percentage of their median (CI95/med) value was calculated for increasing sample sizes. We deduced the sample size that set a 95 % CI lower than 10 % of the median (CI95/med ≤ 10 %). Sample size ensuring CI95/med ≤ 10 %, ranged from 15 to 900 depending on the body region and the dose descriptor considered. In sample sizes recommended by regulatory authorities (i.e., from 10-20 patients), mean CTDIvol and DLP of one sample ranged from 0.50 to 2.00 times its actual value extracted from 2000 samples. The sampling error in CTDIvol and DLP means is high in dose surveys based on small samples of patients. Sample size should be increased at least tenfold to decrease this variability. (orig.)

  11. Sample size choices for XRCT scanning of highly unsaturated soil mixtures

    Directory of Open Access Journals (Sweden)

    Smith Jonathan C.

    2016-01-01

    Full Text Available Highly unsaturated soil mixtures (clay, sand and gravel are used as building materials in many parts of the world, and there is increasing interest in understanding their mechanical and hydraulic behaviour. In the laboratory, x-ray computed tomography (XRCT is becoming more widely used to investigate the microstructures of soils, however a crucial issue for such investigations is the choice of sample size, especially concerning the scanning of soil mixtures where there will be a range of particle and void sizes. In this paper we present a discussion (centred around a new set of XRCT scans on sample sizing for scanning of samples comprising soil mixtures, where a balance has to be made between realistic representation of the soil components and the desire for high resolution scanning, We also comment on the appropriateness of differing sample sizes in comparison to sample sizes used for other geotechnical testing. Void size distributions for the samples are presented and from these some hypotheses are made as to the roles of inter- and intra-aggregate voids in the mechanical behaviour of highly unsaturated soils.

  12. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  13. Choosing a suitable sample size in descriptive sampling

    International Nuclear Information System (INIS)

    Lee, Yong Kyun; Choi, Dong Hoon; Cha, Kyung Joon

    2010-01-01

    Descriptive sampling (DS) is an alternative to crude Monte Carlo sampling (CMCS) in finding solutions to structural reliability problems. It is known to be an effective sampling method in approximating the distribution of a random variable because it uses the deterministic selection of sample values and their random permutation,. However, because this method is difficult to apply to complex simulations, the sample size is occasionally determined without thorough consideration. Input sample variability may cause the sample size to change between runs, leading to poor simulation results. This paper proposes a numerical method for choosing a suitable sample size for use in DS. Using this method, one can estimate a more accurate probability of failure in a reliability problem while running a minimal number of simulations. The method is then applied to several examples and compared with CMCS and conventional DS to validate its usefulness and efficiency

  14. Efficient computation of the joint sample frequency spectra for multiple populations.

    Science.gov (United States)

    Kamm, John A; Terhorst, Jonathan; Song, Yun S

    2017-01-01

    A wide range of studies in population genetics have employed the sample frequency spectrum (SFS), a summary statistic which describes the distribution of mutant alleles at a polymorphic site in a sample of DNA sequences and provides a highly efficient dimensional reduction of large-scale population genomic variation data. Recently, there has been much interest in analyzing the joint SFS data from multiple populations to infer parameters of complex demographic histories, including variable population sizes, population split times, migration rates, admixture proportions, and so on. SFS-based inference methods require accurate computation of the expected SFS under a given demographic model. Although much methodological progress has been made, existing methods suffer from numerical instability and high computational complexity when multiple populations are involved and the sample size is large. In this paper, we present new analytic formulas and algorithms that enable accurate, efficient computation of the expected joint SFS for thousands of individuals sampled from hundreds of populations related by a complex demographic model with arbitrary population size histories (including piecewise-exponential growth). Our results are implemented in a new software package called momi (MOran Models for Inference). Through an empirical study we demonstrate our improvements to numerical stability and computational complexity.

  15. Sample Size Calculations for Population Size Estimation Studies Using Multiplier Methods With Respondent-Driven Sampling Surveys.

    Science.gov (United States)

    Fearon, Elizabeth; Chabata, Sungai T; Thompson, Jennifer A; Cowan, Frances M; Hargreaves, James R

    2017-09-14

    While guidance exists for obtaining population size estimates using multiplier methods with respondent-driven sampling surveys, we lack specific guidance for making sample size decisions. To guide the design of multiplier method population size estimation studies using respondent-driven sampling surveys to reduce the random error around the estimate obtained. The population size estimate is obtained by dividing the number of individuals receiving a service or the number of unique objects distributed (M) by the proportion of individuals in a representative survey who report receipt of the service or object (P). We have developed an approach to sample size calculation, interpreting methods to estimate the variance around estimates obtained using multiplier methods in conjunction with research into design effects and respondent-driven sampling. We describe an application to estimate the number of female sex workers in Harare, Zimbabwe. There is high variance in estimates. Random error around the size estimate reflects uncertainty from M and P, particularly when the estimate of P in the respondent-driven sampling survey is low. As expected, sample size requirements are higher when the design effect of the survey is assumed to be greater. We suggest a method for investigating the effects of sample size on the precision of a population size estimate obtained using multipler methods and respondent-driven sampling. Uncertainty in the size estimate is high, particularly when P is small, so balancing against other potential sources of bias, we advise researchers to consider longer service attendance reference periods and to distribute more unique objects, which is likely to result in a higher estimate of P in the respondent-driven sampling survey. ©Elizabeth Fearon, Sungai T Chabata, Jennifer A Thompson, Frances M Cowan, James R Hargreaves. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 14.09.2017.

  16. Efficient computation of smoothing splines via adaptive basis sampling

    KAUST Repository

    Ma, Ping

    2015-06-24

    © 2015 Biometrika Trust. Smoothing splines provide flexible nonparametric regression estimators. However, the high computational cost of smoothing splines for large datasets has hindered their wide application. In this article, we develop a new method, named adaptive basis sampling, for efficient computation of smoothing splines in super-large samples. Except for the univariate case where the Reinsch algorithm is applicable, a smoothing spline for a regression problem with sample size n can be expressed as a linear combination of n basis functions and its computational complexity is generally O(n3). We achieve a more scalable computation in the multivariate case by evaluating the smoothing spline using a smaller set of basis functions, obtained by an adaptive sampling scheme that uses values of the response variable. Our asymptotic analysis shows that smoothing splines computed via adaptive basis sampling converge to the true function at the same rate as full basis smoothing splines. Using simulation studies and a large-scale deep earth core-mantle boundary imaging study, we show that the proposed method outperforms a sampling method that does not use the values of response variables.

  17. Efficient computation of smoothing splines via adaptive basis sampling

    KAUST Repository

    Ma, Ping; Huang, Jianhua Z.; Zhang, Nan

    2015-01-01

    © 2015 Biometrika Trust. Smoothing splines provide flexible nonparametric regression estimators. However, the high computational cost of smoothing splines for large datasets has hindered their wide application. In this article, we develop a new method, named adaptive basis sampling, for efficient computation of smoothing splines in super-large samples. Except for the univariate case where the Reinsch algorithm is applicable, a smoothing spline for a regression problem with sample size n can be expressed as a linear combination of n basis functions and its computational complexity is generally O(n3). We achieve a more scalable computation in the multivariate case by evaluating the smoothing spline using a smaller set of basis functions, obtained by an adaptive sampling scheme that uses values of the response variable. Our asymptotic analysis shows that smoothing splines computed via adaptive basis sampling converge to the true function at the same rate as full basis smoothing splines. Using simulation studies and a large-scale deep earth core-mantle boundary imaging study, we show that the proposed method outperforms a sampling method that does not use the values of response variables.

  18. The large sample size fallacy.

    Science.gov (United States)

    Lantz, Björn

    2013-06-01

    Significance in the statistical sense has little to do with significance in the common practical sense. Statistical significance is a necessary but not a sufficient condition for practical significance. Hence, results that are extremely statistically significant may be highly nonsignificant in practice. The degree of practical significance is generally determined by the size of the observed effect, not the p-value. The results of studies based on large samples are often characterized by extreme statistical significance despite small or even trivial effect sizes. Interpreting such results as significant in practice without further analysis is referred to as the large sample size fallacy in this article. The aim of this article is to explore the relevance of the large sample size fallacy in contemporary nursing research. Relatively few nursing articles display explicit measures of observed effect sizes or include a qualitative discussion of observed effect sizes. Statistical significance is often treated as an end in itself. Effect sizes should generally be calculated and presented along with p-values for statistically significant results, and observed effect sizes should be discussed qualitatively through direct and explicit comparisons with the effects in related literature. © 2012 Nordic College of Caring Science.

  19. Sample size in qualitative interview studies

    DEFF Research Database (Denmark)

    Malterud, Kirsti; Siersma, Volkert Dirk; Guassora, Ann Dorrit Kristiane

    2016-01-01

    Sample sizes must be ascertained in qualitative studies like in quantitative studies but not by the same means. The prevailing concept for sample size in qualitative studies is “saturation.” Saturation is closely tied to a specific methodology, and the term is inconsistently applied. We propose...... the concept “information power” to guide adequate sample size for qualitative studies. Information power indicates that the more information the sample holds, relevant for the actual study, the lower amount of participants is needed. We suggest that the size of a sample with sufficient information power...... and during data collection of a qualitative study is discussed....

  20. Reducing the Computational Complexity of Reconstruction in Compressed Sensing Nonuniform Sampling

    DEFF Research Database (Denmark)

    Grigoryan, Ruben; Jensen, Tobias Lindstrøm; Arildsen, Thomas

    2013-01-01

    sparse signals, but requires computationally expensive reconstruction algorithms. This can be an obstacle for real-time applications. The reduction of complexity is achieved by applying a multi-coset sampling procedure. This proposed method reduces the size of the dictionary matrix, the size...

  1. Sample size re-assessment leading to a raised sample size does not inflate type I error rate under mild conditions.

    Science.gov (United States)

    Broberg, Per

    2013-07-19

    One major concern with adaptive designs, such as the sample size adjustable designs, has been the fear of inflating the type I error rate. In (Stat Med 23:1023-1038, 2004) it is however proven that when observations follow a normal distribution and the interim result show promise, meaning that the conditional power exceeds 50%, type I error rate is protected. This bound and the distributional assumptions may seem to impose undesirable restrictions on the use of these designs. In (Stat Med 30:3267-3284, 2011) the possibility of going below 50% is explored and a region that permits an increased sample size without inflation is defined in terms of the conditional power at the interim. A criterion which is implicit in (Stat Med 30:3267-3284, 2011) is derived by elementary methods and expressed in terms of the test statistic at the interim to simplify practical use. Mathematical and computational details concerning this criterion are exhibited. Under very general conditions the type I error rate is preserved under sample size adjustable schemes that permit a raise. The main result states that for normally distributed observations raising the sample size when the result looks promising, where the definition of promising depends on the amount of knowledge gathered so far, guarantees the protection of the type I error rate. Also, in the many situations where the test statistic approximately follows a normal law, the deviation from the main result remains negligible. This article provides details regarding the Weibull and binomial distributions and indicates how one may approach these distributions within the current setting. There is thus reason to consider such designs more often, since they offer a means of adjusting an important design feature at little or no cost in terms of error rate.

  2. Concepts in sample size determination

    Directory of Open Access Journals (Sweden)

    Umadevi K Rao

    2012-01-01

    Full Text Available Investigators involved in clinical, epidemiological or translational research, have the drive to publish their results so that they can extrapolate their findings to the population. This begins with the preliminary step of deciding the topic to be studied, the subjects and the type of study design. In this context, the researcher must determine how many subjects would be required for the proposed study. Thus, the number of individuals to be included in the study, i.e., the sample size is an important consideration in the design of many clinical studies. The sample size determination should be based on the difference in the outcome between the two groups studied as in an analytical study, as well as on the accepted p value for statistical significance and the required statistical power to test a hypothesis. The accepted risk of type I error or alpha value, which by convention is set at the 0.05 level in biomedical research defines the cutoff point at which the p value obtained in the study is judged as significant or not. The power in clinical research is the likelihood of finding a statistically significant result when it exists and is typically set to >80%. This is necessary since the most rigorously executed studies may fail to answer the research question if the sample size is too small. Alternatively, a study with too large a sample size will be difficult and will result in waste of time and resources. Thus, the goal of sample size planning is to estimate an appropriate number of subjects for a given study design. This article describes the concepts in estimating the sample size.

  3. Sample Size for Tablet Compression and Capsule Filling Events During Process Validation.

    Science.gov (United States)

    Charoo, Naseem Ahmad; Durivage, Mark; Rahman, Ziyaur; Ayad, Mohamad Haitham

    2017-12-01

    During solid dosage form manufacturing, the uniformity of dosage units (UDU) is ensured by testing samples at 2 stages, that is, blend stage and tablet compression or capsule/powder filling stage. The aim of this work is to propose a sample size selection approach based on quality risk management principles for process performance qualification (PPQ) and continued process verification (CPV) stages by linking UDU to potential formulation and process risk factors. Bayes success run theorem appeared to be the most appropriate approach among various methods considered in this work for computing sample size for PPQ. The sample sizes for high-risk (reliability level of 99%), medium-risk (reliability level of 95%), and low-risk factors (reliability level of 90%) were estimated to be 299, 59, and 29, respectively. Risk-based assignment of reliability levels was supported by the fact that at low defect rate, the confidence to detect out-of-specification units would decrease which must be supplemented with an increase in sample size to enhance the confidence in estimation. Based on level of knowledge acquired during PPQ and the level of knowledge further required to comprehend process, sample size for CPV was calculated using Bayesian statistics to accomplish reduced sampling design for CPV. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  4. How accurate are adolescents in portion-size estimation using the computer tool young adolescents' nutrition assessment on computer (YANA-C)?

    OpenAIRE

    Vereecken, Carine; Dohogne, Sophie; Covents, Marc; Maes, Lea

    2010-01-01

    Computer-administered questionnaires have received increased attention for large-scale population research on nutrition. In Belgium-Flanders, Young Adolescents' Nutrition Assessment on Computer (YANA-C) has been developed. In this tool, standardised photographs are available to assist in portion-size estimation. The purpose of the present study is to assess how accurate adolescents are in estimating portion sizes of food using YANA-C. A convenience sample, aged 11-17 years, estimated the amou...

  5. Experimental determination of size distributions: analyzing proper sample sizes

    International Nuclear Information System (INIS)

    Buffo, A; Alopaeus, V

    2016-01-01

    The measurement of various particle size distributions is a crucial aspect for many applications in the process industry. Size distribution is often related to the final product quality, as in crystallization or polymerization. In other cases it is related to the correct evaluation of heat and mass transfer, as well as reaction rates, depending on the interfacial area between the different phases or to the assessment of yield stresses of polycrystalline metals/alloys samples. The experimental determination of such distributions often involves laborious sampling procedures and the statistical significance of the outcome is rarely investigated. In this work, we propose a novel rigorous tool, based on inferential statistics, to determine the number of samples needed to obtain reliable measurements of size distribution, according to specific requirements defined a priori. Such methodology can be adopted regardless of the measurement technique used. (paper)

  6. [Effect sizes, statistical power and sample sizes in "the Japanese Journal of Psychology"].

    Science.gov (United States)

    Suzukawa, Yumi; Toyoda, Hideki

    2012-04-01

    This study analyzed the statistical power of research studies published in the "Japanese Journal of Psychology" in 2008 and 2009. Sample effect sizes and sample statistical powers were calculated for each statistical test and analyzed with respect to the analytical methods and the fields of the studies. The results show that in the fields like perception, cognition or learning, the effect sizes were relatively large, although the sample sizes were small. At the same time, because of the small sample sizes, some meaningful effects could not be detected. In the other fields, because of the large sample sizes, meaningless effects could be detected. This implies that researchers who could not get large enough effect sizes would use larger samples to obtain significant results.

  7. Children's accuracy of portion size estimation using digital food images: effects of interface design and size of image on computer screen.

    Science.gov (United States)

    Baranowski, Tom; Baranowski, Janice C; Watson, Kathleen B; Martin, Shelby; Beltran, Alicia; Islam, Noemi; Dadabhoy, Hafza; Adame, Su-heyla; Cullen, Karen; Thompson, Debbe; Buday, Richard; Subar, Amy

    2011-03-01

    To test the effect of image size and presence of size cues on the accuracy of portion size estimation by children. Children were randomly assigned to seeing images with or without food size cues (utensils and checked tablecloth) and were presented with sixteen food models (foods commonly eaten by children) in varying portion sizes, one at a time. They estimated each food model's portion size by selecting a digital food image. The same food images were presented in two ways: (i) as small, graduated portion size images all on one screen or (ii) by scrolling across large, graduated portion size images, one per sequential screen. Laboratory-based with computer and food models. Volunteer multi-ethnic sample of 120 children, equally distributed by gender and ages (8 to 13 years) in 2008-2009. Average percentage of correctly classified foods was 60·3 %. There were no differences in accuracy by any design factor or demographic characteristic. Multiple small pictures on the screen at once took half the time to estimate portion size compared with scrolling through large pictures. Larger pictures had more overestimation of size. Multiple images of successively larger portion sizes of a food on one computer screen facilitated quicker portion size responses with no decrease in accuracy. This is the method of choice for portion size estimation on a computer.

  8. Relative efficiency and sample size for cluster randomized trials with variable cluster sizes.

    Science.gov (United States)

    You, Zhiying; Williams, O Dale; Aban, Inmaculada; Kabagambe, Edmond Kato; Tiwari, Hemant K; Cutter, Gary

    2011-02-01

    The statistical power of cluster randomized trials depends on two sample size components, the number of clusters per group and the numbers of individuals within clusters (cluster size). Variable cluster sizes are common and this variation alone may have significant impact on study power. Previous approaches have taken this into account by either adjusting total sample size using a designated design effect or adjusting the number of clusters according to an assessment of the relative efficiency of unequal versus equal cluster sizes. This article defines a relative efficiency of unequal versus equal cluster sizes using noncentrality parameters, investigates properties of this measure, and proposes an approach for adjusting the required sample size accordingly. We focus on comparing two groups with normally distributed outcomes using t-test, and use the noncentrality parameter to define the relative efficiency of unequal versus equal cluster sizes and show that statistical power depends only on this parameter for a given number of clusters. We calculate the sample size required for an unequal cluster sizes trial to have the same power as one with equal cluster sizes. Relative efficiency based on the noncentrality parameter is straightforward to calculate and easy to interpret. It connects the required mean cluster size directly to the required sample size with equal cluster sizes. Consequently, our approach first determines the sample size requirements with equal cluster sizes for a pre-specified study power and then calculates the required mean cluster size while keeping the number of clusters unchanged. Our approach allows adjustment in mean cluster size alone or simultaneous adjustment in mean cluster size and number of clusters, and is a flexible alternative to and a useful complement to existing methods. Comparison indicated that we have defined a relative efficiency that is greater than the relative efficiency in the literature under some conditions. Our measure

  9. Type-II generalized family-wise error rate formulas with application to sample size determination.

    Science.gov (United States)

    Delorme, Phillipe; de Micheaux, Pierre Lafaye; Liquet, Benoit; Riou, Jérémie

    2016-07-20

    Multiple endpoints are increasingly used in clinical trials. The significance of some of these clinical trials is established if at least r null hypotheses are rejected among m that are simultaneously tested. The usual approach in multiple hypothesis testing is to control the family-wise error rate, which is defined as the probability that at least one type-I error is made. More recently, the q-generalized family-wise error rate has been introduced to control the probability of making at least q false rejections. For procedures controlling this global type-I error rate, we define a type-II r-generalized family-wise error rate, which is directly related to the r-power defined as the probability of rejecting at least r false null hypotheses. We obtain very general power formulas that can be used to compute the sample size for single-step and step-wise procedures. These are implemented in our R package rPowerSampleSize available on the CRAN, making them directly available to end users. Complexities of the formulas are presented to gain insight into computation time issues. Comparison with Monte Carlo strategy is also presented. We compute sample sizes for two clinical trials involving multiple endpoints: one designed to investigate the effectiveness of a drug against acute heart failure and the other for the immunogenicity of a vaccine strategy against pneumococcus. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Neuromuscular dose-response studies: determining sample size.

    Science.gov (United States)

    Kopman, A F; Lien, C A; Naguib, M

    2011-02-01

    Investigators planning dose-response studies of neuromuscular blockers have rarely used a priori power analysis to determine the minimal sample size their protocols require. Institutional Review Boards and peer-reviewed journals now generally ask for this information. This study outlines a proposed method for meeting these requirements. The slopes of the dose-response relationships of eight neuromuscular blocking agents were determined using regression analysis. These values were substituted for γ in the Hill equation. When this is done, the coefficient of variation (COV) around the mean value of the ED₅₀ for each drug is easily calculated. Using these values, we performed an a priori one-sample two-tailed t-test of the means to determine the required sample size when the allowable error in the ED₅₀ was varied from ±10-20%. The COV averaged 22% (range 15-27%). We used a COV value of 25% in determining the sample size. If the allowable error in finding the mean ED₅₀ is ±15%, a sample size of 24 is needed to achieve a power of 80%. Increasing 'accuracy' beyond this point requires increasing greater sample sizes (e.g. an 'n' of 37 for a ±12% error). On the basis of the results of this retrospective analysis, a total sample size of not less than 24 subjects should be adequate for determining a neuromuscular blocking drug's clinical potency with a reasonable degree of assurance.

  11. Estimating Sample Size for Usability Testing

    Directory of Open Access Journals (Sweden)

    Alex Cazañas

    2017-02-01

    Full Text Available One strategy used to assure that an interface meets user requirements is to conduct usability testing. When conducting such testing one of the unknowns is sample size. Since extensive testing is costly, minimizing the number of participants can contribute greatly to successful resource management of a project. Even though a significant number of models have been proposed to estimate sample size in usability testing, there is still not consensus on the optimal size. Several studies claim that 3 to 5 users suffice to uncover 80% of problems in a software interface. However, many other studies challenge this assertion. This study analyzed data collected from the user testing of a web application to verify the rule of thumb, commonly known as the “magic number 5”. The outcomes of the analysis showed that the 5-user rule significantly underestimates the required sample size to achieve reasonable levels of problem detection.

  12. Sensitivity and specificity of normality tests and consequences on reference interval accuracy at small sample size: a computer-simulation study.

    Science.gov (United States)

    Le Boedec, Kevin

    2016-12-01

    According to international guidelines, parametric methods must be chosen for RI construction when the sample size is small and the distribution is Gaussian. However, normality tests may not be accurate at small sample size. The purpose of the study was to evaluate normality test performance to properly identify samples extracted from a Gaussian population at small sample sizes, and assess the consequences on RI accuracy of applying parametric methods to samples that falsely identified the parent population as Gaussian. Samples of n = 60 and n = 30 values were randomly selected 100 times from simulated Gaussian, lognormal, and asymmetric populations of 10,000 values. The sensitivity and specificity of 4 normality tests were compared. Reference intervals were calculated using 6 different statistical methods from samples that falsely identified the parent population as Gaussian, and their accuracy was compared. Shapiro-Wilk and D'Agostino-Pearson tests were the best performing normality tests. However, their specificity was poor at sample size n = 30 (specificity for P Box-Cox transformation) on all samples regardless of their distribution or adjusting, the significance level of normality tests depending on sample size would limit the risk of constructing inaccurate RI. © 2016 American Society for Veterinary Clinical Pathology.

  13. Sample Size Determination for One- and Two-Sample Trimmed Mean Tests

    Science.gov (United States)

    Luh, Wei-Ming; Olejnik, Stephen; Guo, Jiin-Huarng

    2008-01-01

    Formulas to determine the necessary sample sizes for parametric tests of group comparisons are available from several sources and appropriate when population distributions are normal. However, in the context of nonnormal population distributions, researchers recommend Yuen's trimmed mean test, but formulas to determine sample sizes have not been…

  14. Sample size of the reference sample in a case-augmented study.

    Science.gov (United States)

    Ghosh, Palash; Dewanji, Anup

    2017-05-01

    The case-augmented study, in which a case sample is augmented with a reference (random) sample from the source population with only covariates information known, is becoming popular in different areas of applied science such as pharmacovigilance, ecology, and econometrics. In general, the case sample is available from some source (for example, hospital database, case registry, etc.); however, the reference sample is required to be drawn from the corresponding source population. The required minimum size of the reference sample is an important issue in this regard. In this work, we address the minimum sample size calculation and discuss related issues. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  15. 40 CFR 80.127 - Sample size guidelines.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Sample size guidelines. 80.127 Section 80.127 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Attest Engagements § 80.127 Sample size guidelines. In performing the...

  16. Determination of the optimal sample size for a clinical trial accounting for the population size.

    Science.gov (United States)

    Stallard, Nigel; Miller, Frank; Day, Simon; Hee, Siew Wan; Madan, Jason; Zohar, Sarah; Posch, Martin

    2017-07-01

    The problem of choosing a sample size for a clinical trial is a very common one. In some settings, such as rare diseases or other small populations, the large sample sizes usually associated with the standard frequentist approach may be infeasible, suggesting that the sample size chosen should reflect the size of the population under consideration. Incorporation of the population size is possible in a decision-theoretic approach either explicitly by assuming that the population size is fixed and known, or implicitly through geometric discounting of the gain from future patients reflecting the expected population size. This paper develops such approaches. Building on previous work, an asymptotic expression is derived for the sample size for single and two-arm clinical trials in the general case of a clinical trial with a primary endpoint with a distribution of one parameter exponential family form that optimizes a utility function that quantifies the cost and gain per patient as a continuous function of this parameter. It is shown that as the size of the population, N, or expected size, N∗ in the case of geometric discounting, becomes large, the optimal trial size is O(N1/2) or O(N∗1/2). The sample size obtained from the asymptotic expression is also compared with the exact optimal sample size in examples with responses with Bernoulli and Poisson distributions, showing that the asymptotic approximations can also be reasonable in relatively small sample sizes. © 2016 The Author. Biometrical Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Publication Bias in Psychology: A Diagnosis Based on the Correlation between Effect Size and Sample Size

    Science.gov (United States)

    Kühberger, Anton; Fritz, Astrid; Scherndl, Thomas

    2014-01-01

    Background The p value obtained from a significance test provides no information about the magnitude or importance of the underlying phenomenon. Therefore, additional reporting of effect size is often recommended. Effect sizes are theoretically independent from sample size. Yet this may not hold true empirically: non-independence could indicate publication bias. Methods We investigate whether effect size is independent from sample size in psychological research. We randomly sampled 1,000 psychological articles from all areas of psychological research. We extracted p values, effect sizes, and sample sizes of all empirical papers, and calculated the correlation between effect size and sample size, and investigated the distribution of p values. Results We found a negative correlation of r = −.45 [95% CI: −.53; −.35] between effect size and sample size. In addition, we found an inordinately high number of p values just passing the boundary of significance. Additional data showed that neither implicit nor explicit power analysis could account for this pattern of findings. Conclusion The negative correlation between effect size and samples size, and the biased distribution of p values indicate pervasive publication bias in the entire field of psychology. PMID:25192357

  18. [Practical aspects regarding sample size in clinical research].

    Science.gov (United States)

    Vega Ramos, B; Peraza Yanes, O; Herrera Correa, G; Saldívar Toraya, S

    1996-01-01

    The knowledge of the right sample size let us to be sure if the published results in medical papers had a suitable design and a proper conclusion according to the statistics analysis. To estimate the sample size we must consider the type I error, type II error, variance, the size of the effect, significance and power of the test. To decide what kind of mathematics formula will be used, we must define what kind of study we have, it means if its a prevalence study, a means values one or a comparative one. In this paper we explain some basic topics of statistics and we describe four simple samples of estimation of sample size.

  19. Sample size calculation in metabolic phenotyping studies.

    Science.gov (United States)

    Billoir, Elise; Navratil, Vincent; Blaise, Benjamin J

    2015-09-01

    The number of samples needed to identify significant effects is a key question in biomedical studies, with consequences on experimental designs, costs and potential discoveries. In metabolic phenotyping studies, sample size determination remains a complex step. This is due particularly to the multiple hypothesis-testing framework and the top-down hypothesis-free approach, with no a priori known metabolic target. Until now, there was no standard procedure available to address this purpose. In this review, we discuss sample size estimation procedures for metabolic phenotyping studies. We release an automated implementation of the Data-driven Sample size Determination (DSD) algorithm for MATLAB and GNU Octave. Original research concerning DSD was published elsewhere. DSD allows the determination of an optimized sample size in metabolic phenotyping studies. The procedure uses analytical data only from a small pilot cohort to generate an expanded data set. The statistical recoupling of variables procedure is used to identify metabolic variables, and their intensity distributions are estimated by Kernel smoothing or log-normal density fitting. Statistically significant metabolic variations are evaluated using the Benjamini-Yekutieli correction and processed for data sets of various sizes. Optimal sample size determination is achieved in a context of biomarker discovery (at least one statistically significant variation) or metabolic exploration (a maximum of statistically significant variations). DSD toolbox is encoded in MATLAB R2008A (Mathworks, Natick, MA) for Kernel and log-normal estimates, and in GNU Octave for log-normal estimates (Kernel density estimates are not robust enough in GNU octave). It is available at http://www.prabi.fr/redmine/projects/dsd/repository, with a tutorial at http://www.prabi.fr/redmine/projects/dsd/wiki. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  20. Sample size determination and power

    CERN Document Server

    Ryan, Thomas P, Jr

    2013-01-01

    THOMAS P. RYAN, PhD, teaches online advanced statistics courses for Northwestern University and The Institute for Statistics Education in sample size determination, design of experiments, engineering statistics, and regression analysis.

  1. Sample size determination in clinical trials with multiple endpoints

    CERN Document Server

    Sozu, Takashi; Hamasaki, Toshimitsu; Evans, Scott R

    2015-01-01

    This book integrates recent methodological developments for calculating the sample size and power in trials with more than one endpoint considered as multiple primary or co-primary, offering an important reference work for statisticians working in this area. The determination of sample size and the evaluation of power are fundamental and critical elements in the design of clinical trials. If the sample size is too small, important effects may go unnoticed; if the sample size is too large, it represents a waste of resources and unethically puts more participants at risk than necessary. Recently many clinical trials have been designed with more than one endpoint considered as multiple primary or co-primary, creating a need for new approaches to the design and analysis of these clinical trials. The book focuses on the evaluation of power and sample size determination when comparing the effects of two interventions in superiority clinical trials with multiple endpoints. Methods for sample size calculation in clin...

  2. Accelerating inference for diffusions observed with measurement error and large sample sizes using approximate Bayesian computation

    DEFF Research Database (Denmark)

    Picchini, Umberto; Forman, Julie Lyng

    2016-01-01

    a nonlinear stochastic differential equation model observed with correlated measurement errors and an application to protein folding modelling. An approximate Bayesian computation (ABC)-MCMC algorithm is suggested to allow inference for model parameters within reasonable time constraints. The ABC algorithm......In recent years, dynamical modelling has been provided with a range of breakthrough methods to perform exact Bayesian inference. However, it is often computationally unfeasible to apply exact statistical methodologies in the context of large data sets and complex models. This paper considers...... applications. A simulation study is conducted to compare our strategy with exact Bayesian inference, the latter resulting two orders of magnitude slower than ABC-MCMC for the considered set-up. Finally, the ABC algorithm is applied to a large size protein data. The suggested methodology is fairly general...

  3. Predicting sample size required for classification performance

    Directory of Open Access Journals (Sweden)

    Figueroa Rosa L

    2012-02-01

    Full Text Available Abstract Background Supervised learning methods need annotated data in order to generate efficient models. Annotated data, however, is a relatively scarce resource and can be expensive to obtain. For both passive and active learning methods, there is a need to estimate the size of the annotated sample required to reach a performance target. Methods We designed and implemented a method that fits an inverse power law model to points of a given learning curve created using a small annotated training set. Fitting is carried out using nonlinear weighted least squares optimization. The fitted model is then used to predict the classifier's performance and confidence interval for larger sample sizes. For evaluation, the nonlinear weighted curve fitting method was applied to a set of learning curves generated using clinical text and waveform classification tasks with active and passive sampling methods, and predictions were validated using standard goodness of fit measures. As control we used an un-weighted fitting method. Results A total of 568 models were fitted and the model predictions were compared with the observed performances. Depending on the data set and sampling method, it took between 80 to 560 annotated samples to achieve mean average and root mean squared error below 0.01. Results also show that our weighted fitting method outperformed the baseline un-weighted method (p Conclusions This paper describes a simple and effective sample size prediction algorithm that conducts weighted fitting of learning curves. The algorithm outperformed an un-weighted algorithm described in previous literature. It can help researchers determine annotation sample size for supervised machine learning.

  4. Estimation of sample size and testing power (Part 4).

    Science.gov (United States)

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2012-01-01

    Sample size estimation is necessary for any experimental or survey research. An appropriate estimation of sample size based on known information and statistical knowledge is of great significance. This article introduces methods of sample size estimation of difference test for data with the design of one factor with two levels, including sample size estimation formulas and realization based on the formulas and the POWER procedure of SAS software for quantitative data and qualitative data with the design of one factor with two levels. In addition, this article presents examples for analysis, which will play a leading role for researchers to implement the repetition principle during the research design phase.

  5. Sample size determination for equivalence assessment with multiple endpoints.

    Science.gov (United States)

    Sun, Anna; Dong, Xiaoyu; Tsong, Yi

    2014-01-01

    Equivalence assessment between a reference and test treatment is often conducted by two one-sided tests (TOST). The corresponding power function and sample size determination can be derived from a joint distribution of the sample mean and sample variance. When an equivalence trial is designed with multiple endpoints, it often involves several sets of two one-sided tests. A naive approach for sample size determination in this case would select the largest sample size required for each endpoint. However, such a method ignores the correlation among endpoints. With the objective to reject all endpoints and when the endpoints are uncorrelated, the power function is the production of all power functions for individual endpoints. With correlated endpoints, the sample size and power should be adjusted for such a correlation. In this article, we propose the exact power function for the equivalence test with multiple endpoints adjusted for correlation under both crossover and parallel designs. We further discuss the differences in sample size for the naive method without and with correlation adjusted methods and illustrate with an in vivo bioequivalence crossover study with area under the curve (AUC) and maximum concentration (Cmax) as the two endpoints.

  6. Preeminence and prerequisites of sample size calculations in clinical trials

    OpenAIRE

    Richa Singhal; Rakesh Rana

    2015-01-01

    The key components while planning a clinical study are the study design, study duration, and sample size. These features are an integral part of planning a clinical trial efficiently, ethically, and cost-effectively. This article describes some of the prerequisites for sample size calculation. It also explains that sample size calculation is different for different study designs. The article in detail describes the sample size calculation for a randomized controlled trial when the primary out...

  7. Optimum sample size allocation to minimize cost or maximize power for the two-sample trimmed mean test.

    Science.gov (United States)

    Guo, Jiin-Huarng; Luh, Wei-Ming

    2009-05-01

    When planning a study, sample size determination is one of the most important tasks facing the researcher. The size will depend on the purpose of the study, the cost limitations, and the nature of the data. By specifying the standard deviation ratio and/or the sample size ratio, the present study considers the problem of heterogeneous variances and non-normality for Yuen's two-group test and develops sample size formulas to minimize the total cost or maximize the power of the test. For a given power, the sample size allocation ratio can be manipulated so that the proposed formulas can minimize the total cost, the total sample size, or the sum of total sample size and total cost. On the other hand, for a given total cost, the optimum sample size allocation ratio can maximize the statistical power of the test. After the sample size is determined, the present simulation applies Yuen's test to the sample generated, and then the procedure is validated in terms of Type I errors and power. Simulation results show that the proposed formulas can control Type I errors and achieve the desired power under the various conditions specified. Finally, the implications for determining sample sizes in experimental studies and future research are discussed.

  8. Optimal sample size for probability of detection curves

    International Nuclear Information System (INIS)

    Annis, Charles; Gandossi, Luca; Martin, Oliver

    2013-01-01

    Highlights: • We investigate sample size requirement to develop probability of detection curves. • We develop simulations to determine effective inspection target sizes, number and distribution. • We summarize these findings and provide guidelines for the NDE practitioner. -- Abstract: The use of probability of detection curves to quantify the reliability of non-destructive examination (NDE) systems is common in the aeronautical industry, but relatively less so in the nuclear industry, at least in European countries. Due to the nature of the components being inspected, sample sizes tend to be much lower. This makes the manufacturing of test pieces with representative flaws, in sufficient numbers, so to draw statistical conclusions on the reliability of the NDT system under investigation, quite costly. The European Network for Inspection and Qualification (ENIQ) has developed an inspection qualification methodology, referred to as the ENIQ Methodology. It has become widely used in many European countries and provides assurance on the reliability of NDE systems, but only qualitatively. The need to quantify the output of inspection qualification has become more important as structural reliability modelling and quantitative risk-informed in-service inspection methodologies become more widely used. A measure of the NDE reliability is necessary to quantify risk reduction after inspection and probability of detection (POD) curves provide such a metric. The Joint Research Centre, Petten, The Netherlands supported ENIQ by investigating the question of the sample size required to determine a reliable POD curve. As mentioned earlier manufacturing of test pieces with defects that are typically found in nuclear power plants (NPPs) is usually quite expensive. Thus there is a tendency to reduce sample sizes, which in turn increases the uncertainty associated with the resulting POD curve. The main question in conjunction with POS curves is the appropriate sample size. Not

  9. Sample size for morphological traits of pigeonpea

    Directory of Open Access Journals (Sweden)

    Giovani Facco

    2015-12-01

    Full Text Available The objectives of this study were to determine the sample size (i.e., number of plants required to accurately estimate the average of morphological traits of pigeonpea (Cajanus cajan L. and to check for variability in sample size between evaluation periods and seasons. Two uniformity trials (i.e., experiments without treatment were conducted for two growing seasons. In the first season (2011/2012, the seeds were sown by broadcast seeding, and in the second season (2012/2013, the seeds were sown in rows spaced 0.50 m apart. The ground area in each experiment was 1,848 m2, and 360 plants were marked in the central area, in a 2 m × 2 m grid. Three morphological traits (e.g., number of nodes, plant height and stem diameter were evaluated 13 times during the first season and 22 times in the second season. Measurements for all three morphological traits were normally distributed and confirmed through the Kolmogorov-Smirnov test. Randomness was confirmed using the Run Test, and the descriptive statistics were calculated. For each trait, the sample size (n was calculated for the semiamplitudes of the confidence interval (i.e., estimation error equal to 2, 4, 6, ..., 20% of the estimated mean with a confidence coefficient (1-? of 95%. Subsequently, n was fixed at 360 plants, and the estimation error of the estimated percentage of the average for each trait was calculated. Variability of the sample size for the pigeonpea culture was observed between the morphological traits evaluated, among the evaluation periods and between seasons. Therefore, to assess with an accuracy of 6% of the estimated average, at least 136 plants must be evaluated throughout the pigeonpea crop cycle to determine the sample size for the traits (e.g., number of nodes, plant height and stem diameter in the different evaluation periods and between seasons. 

  10. Sample Size Estimation for Negative Binomial Regression Comparing Rates of Recurrent Events with Unequal Follow-Up Time.

    Science.gov (United States)

    Tang, Yongqiang

    2015-01-01

    A sample size formula is derived for negative binomial regression for the analysis of recurrent events, in which subjects can have unequal follow-up time. We obtain sharp lower and upper bounds on the required size, which is easy to compute. The upper bound is generally only slightly larger than the required size, and hence can be used to approximate the sample size. The lower and upper size bounds can be decomposed into two terms. The first term relies on the mean number of events in each group, and the second term depends on two factors that measure, respectively, the extent of between-subject variability in event rates, and follow-up time. Simulation studies are conducted to assess the performance of the proposed method. An application of our formulae to a multiple sclerosis trial is provided.

  11. An Analytic Solution to the Computation of Power and Sample Size for Genetic Association Studies under a Pleiotropic Mode of Inheritance.

    Science.gov (United States)

    Gordon, Derek; Londono, Douglas; Patel, Payal; Kim, Wonkuk; Finch, Stephen J; Heiman, Gary A

    2016-01-01

    Our motivation here is to calculate the power of 3 statistical tests used when there are genetic traits that operate under a pleiotropic mode of inheritance and when qualitative phenotypes are defined by use of thresholds for the multiple quantitative phenotypes. Specifically, we formulate a multivariate function that provides the probability that an individual has a vector of specific quantitative trait values conditional on having a risk locus genotype, and we apply thresholds to define qualitative phenotypes (affected, unaffected) and compute penetrances and conditional genotype frequencies based on the multivariate function. We extend the analytic power and minimum-sample-size-necessary (MSSN) formulas for 2 categorical data-based tests (genotype, linear trend test [LTT]) of genetic association to the pleiotropic model. We further compare the MSSN of the genotype test and the LTT with that of a multivariate ANOVA (Pillai). We approximate the MSSN for statistics by linear models using a factorial design and ANOVA. With ANOVA decomposition, we determine which factors most significantly change the power/MSSN for all statistics. Finally, we determine which test statistics have the smallest MSSN. In this work, MSSN calculations are for 2 traits (bivariate distributions) only (for illustrative purposes). We note that the calculations may be extended to address any number of traits. Our key findings are that the genotype test usually has lower MSSN requirements than the LTT. More inclusive thresholds (top/bottom 25% vs. top/bottom 10%) have higher sample size requirements. The Pillai test has a much larger MSSN than both the genotype test and the LTT, as a result of sample selection. With these formulas, researchers can specify how many subjects they must collect to localize genes for pleiotropic phenotypes. © 2017 S. Karger AG, Basel.

  12. Preeminence and prerequisites of sample size calculations in clinical trials

    Directory of Open Access Journals (Sweden)

    Richa Singhal

    2015-01-01

    Full Text Available The key components while planning a clinical study are the study design, study duration, and sample size. These features are an integral part of planning a clinical trial efficiently, ethically, and cost-effectively. This article describes some of the prerequisites for sample size calculation. It also explains that sample size calculation is different for different study designs. The article in detail describes the sample size calculation for a randomized controlled trial when the primary outcome is a continuous variable and when it is a proportion or a qualitative variable.

  13. PET/CT in cancer: moderate sample sizes may suffice to justify replacement of a regional gold standard

    DEFF Research Database (Denmark)

    Gerke, Oke; Poulsen, Mads Hvid; Bouchelouche, Kirsten

    2009-01-01

    PURPOSE: For certain cancer indications, the current patient evaluation strategy is a perfect but locally restricted gold standard procedure. If positron emission tomography/computed tomography (PET/CT) can be shown to be reliable within the gold standard region and if it can be argued that PET...... of metastasized prostate cancer. RESULTS: An added value in accuracy of PET/CT in adjacent areas can outweigh a downsized target level of accuracy in the gold standard region, justifying smaller sample sizes. CONCLUSIONS: If PET/CT provides an accuracy benefit in adjacent regions, then sample sizes can be reduced....../CT also performs well in adjacent areas, then sample sizes in accuracy studies can be reduced. PROCEDURES: Traditional standard power calculations for demonstrating sensitivities of both 80% and 90% are shown. The argument is then described in general terms and demonstrated by an ongoing study...

  14. Revisiting sample size: are big trials the answer?

    Science.gov (United States)

    Lurati Buse, Giovanna A L; Botto, Fernando; Devereaux, P J

    2012-07-18

    The superiority of the evidence generated in randomized controlled trials over observational data is not only conditional to randomization. Randomized controlled trials require proper design and implementation to provide a reliable effect estimate. Adequate random sequence generation, allocation implementation, analyses based on the intention-to-treat principle, and sufficient power are crucial to the quality of a randomized controlled trial. Power, or the probability of the trial to detect a difference when a real difference between treatments exists, strongly depends on sample size. The quality of orthopaedic randomized controlled trials is frequently threatened by a limited sample size. This paper reviews basic concepts and pitfalls in sample-size estimation and focuses on the importance of large trials in the generation of valid evidence.

  15. Test of a sample container for shipment of small size plutonium samples with PAT-2

    International Nuclear Information System (INIS)

    Kuhn, E.; Aigner, H.; Deron, S.

    1981-11-01

    A light-weight container for the air transport of plutonium, to be designated PAT-2, has been developed in the USA and is presently undergoing licensing. The very limited effective space for bearing plutonium required the design of small size sample canisters to meet the needs of international safeguards for the shipment of plutonium samples. The applicability of a small canister for the sampling of small size powder and solution samples has been tested in an intralaboratory experiment. The results of the experiment, based on the concept of pre-weighed samples, show that the tested canister can successfully be used for the sampling of small size PuO 2 -powder samples of homogeneous source material, as well as for dried aliquands of plutonium nitrate solutions. (author)

  16. Causality in Statistical Power: Isomorphic Properties of Measurement, Research Design, Effect Size, and Sample Size

    Directory of Open Access Journals (Sweden)

    R. Eric Heidel

    2016-01-01

    Full Text Available Statistical power is the ability to detect a significant effect, given that the effect actually exists in a population. Like most statistical concepts, statistical power tends to induce cognitive dissonance in hepatology researchers. However, planning for statistical power by an a priori sample size calculation is of paramount importance when designing a research study. There are five specific empirical components that make up an a priori sample size calculation: the scale of measurement of the outcome, the research design, the magnitude of the effect size, the variance of the effect size, and the sample size. A framework grounded in the phenomenon of isomorphism, or interdependencies amongst different constructs with similar forms, will be presented to understand the isomorphic effects of decisions made on each of the five aforementioned components of statistical power.

  17. Sampling efficiency of modified 37-mm sampling cassettes using computational fluid dynamics.

    Science.gov (United States)

    Anthony, T Renée; Sleeth, Darrah; Volckens, John

    2016-01-01

    In the U.S., most industrial hygiene practitioners continue to rely on the closed-face cassette (CFC) to assess worker exposures to hazardous dusts, primarily because ease of use, cost, and familiarity. However, mass concentrations measured with this classic sampler underestimate exposures to larger particles throughout the inhalable particulate mass (IPM) size range (up to aerodynamic diameters of 100 μm). To investigate whether the current 37-mm inlet cap can be redesigned to better meet the IPM sampling criterion, computational fluid dynamics (CFD) models were developed, and particle sampling efficiencies associated with various modifications to the CFC inlet cap were determined. Simulations of fluid flow (standard k-epsilon turbulent model) and particle transport (laminar trajectories, 1-116 μm) were conducted using sampling flow rates of 10 L min(-1) in slow moving air (0.2 m s(-1)) in the facing-the-wind orientation. Combinations of seven inlet shapes and three inlet diameters were evaluated as candidates to replace the current 37-mm inlet cap. For a given inlet geometry, differences in sampler efficiency between inlet diameters averaged less than 1% for particles through 100 μm, but the largest opening was found to increase the efficiency for the 116 μm particles by 14% for the flat inlet cap. A substantial reduction in sampler efficiency was identified for sampler inlets with side walls extending beyond the dimension of the external lip of the current 37-mm CFC. The inlet cap based on the 37-mm CFC dimensions with an expanded 15-mm entry provided the best agreement with facing-the-wind human aspiration efficiency. The sampler efficiency was increased with a flat entry or with a thin central lip adjacent to the new enlarged entry. This work provides a substantial body of sampling efficiency estimates as a function of particle size and inlet geometry for personal aerosol samplers.

  18. Maximum type I error rate inflation from sample size reassessment when investigators are blind to treatment labels.

    Science.gov (United States)

    Żebrowska, Magdalena; Posch, Martin; Magirr, Dominic

    2016-05-30

    Consider a parallel group trial for the comparison of an experimental treatment to a control, where the second-stage sample size may depend on the blinded primary endpoint data as well as on additional blinded data from a secondary endpoint. For the setting of normally distributed endpoints, we demonstrate that this may lead to an inflation of the type I error rate if the null hypothesis holds for the primary but not the secondary endpoint. We derive upper bounds for the inflation of the type I error rate, both for trials that employ random allocation and for those that use block randomization. We illustrate the worst-case sample size reassessment rule in a case study. For both randomization strategies, the maximum type I error rate increases with the effect size in the secondary endpoint and the correlation between endpoints. The maximum inflation increases with smaller block sizes if information on the block size is used in the reassessment rule. Based on our findings, we do not question the well-established use of blinded sample size reassessment methods with nuisance parameter estimates computed from the blinded interim data of the primary endpoint. However, we demonstrate that the type I error rate control of these methods relies on the application of specific, binding, pre-planned and fully algorithmic sample size reassessment rules and does not extend to general or unplanned sample size adjustments based on blinded data. © 2015 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd. © 2015 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.

  19. Sample-size dependence of diversity indices and the determination of sufficient sample size in a high-diversity deep-sea environment

    OpenAIRE

    Soetaert, K.; Heip, C.H.R.

    1990-01-01

    Diversity indices, although designed for comparative purposes, often cannot be used as such, due to their sample-size dependence. It is argued here that this dependence is more pronounced in high diversity than in low diversity assemblages and that indices more sensitive to rarer species require larger sample sizes to estimate diversity with reasonable precision than indices which put more weight on commoner species. This was tested for Hill's diversity number N sub(0) to N sub( proportional ...

  20. Sample size calculation for comparing two negative binomial rates.

    Science.gov (United States)

    Zhu, Haiyuan; Lakkis, Hassan

    2014-02-10

    Negative binomial model has been increasingly used to model the count data in recent clinical trials. It is frequently chosen over Poisson model in cases of overdispersed count data that are commonly seen in clinical trials. One of the challenges of applying negative binomial model in clinical trial design is the sample size estimation. In practice, simulation methods have been frequently used for sample size estimation. In this paper, an explicit formula is developed to calculate sample size based on the negative binomial model. Depending on different approaches to estimate the variance under null hypothesis, three variations of the sample size formula are proposed and discussed. Important characteristics of the formula include its accuracy and its ability to explicitly incorporate dispersion parameter and exposure time. The performance of the formula with each variation is assessed using simulations. Copyright © 2013 John Wiley & Sons, Ltd.

  1. Estimation of sample size and testing power (part 5).

    Science.gov (United States)

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2012-02-01

    Estimation of sample size and testing power is an important component of research design. This article introduced methods for sample size and testing power estimation of difference test for quantitative and qualitative data with the single-group design, the paired design or the crossover design. To be specific, this article introduced formulas for sample size and testing power estimation of difference test for quantitative and qualitative data with the above three designs, the realization based on the formulas and the POWER procedure of SAS software and elaborated it with examples, which will benefit researchers for implementing the repetition principle.

  2. Frictional behaviour of sandstone: A sample-size dependent triaxial investigation

    Science.gov (United States)

    Roshan, Hamid; Masoumi, Hossein; Regenauer-Lieb, Klaus

    2017-01-01

    Frictional behaviour of rocks from the initial stage of loading to final shear displacement along the formed shear plane has been widely investigated in the past. However the effect of sample size on such frictional behaviour has not attracted much attention. This is mainly related to the limitations in rock testing facilities as well as the complex mechanisms involved in sample-size dependent frictional behaviour of rocks. In this study, a suite of advanced triaxial experiments was performed on Gosford sandstone samples at different sizes and confining pressures. The post-peak response of the rock along the formed shear plane has been captured for the analysis with particular interest in sample-size dependency. Several important phenomena have been observed from the results of this study: a) the rate of transition from brittleness to ductility in rock is sample-size dependent where the relatively smaller samples showed faster transition toward ductility at any confining pressure; b) the sample size influences the angle of formed shear band and c) the friction coefficient of the formed shear plane is sample-size dependent where the relatively smaller sample exhibits lower friction coefficient compared to larger samples. We interpret our results in terms of a thermodynamics approach in which the frictional properties for finite deformation are viewed as encompassing a multitude of ephemeral slipping surfaces prior to the formation of the through going fracture. The final fracture itself is seen as a result of the self-organisation of a sufficiently large ensemble of micro-slip surfaces and therefore consistent in terms of the theory of thermodynamics. This assumption vindicates the use of classical rock mechanics experiments to constrain failure of pressure sensitive rocks and the future imaging of these micro-slips opens an exciting path for research in rock failure mechanisms.

  3. Effects of sample size on the second magnetization peak in ...

    Indian Academy of Sciences (India)

    the sample size decreases – a result that could be interpreted as a size effect in the order– disorder vortex matter phase transition. However, local magnetic measurements trace this effect to metastable disordered vortex states, revealing the same order–disorder transition induction in samples of different size. Keywords.

  4. Constrained statistical inference: sample-size tables for ANOVA and regression

    Directory of Open Access Journals (Sweden)

    Leonard eVanbrabant

    2015-01-01

    Full Text Available Researchers in the social and behavioral sciences often have clear expectations about the order/direction of the parameters in their statistical model. For example, a researcher might expect that regression coefficient beta1 is larger than beta2 and beta3. The corresponding hypothesis is H: beta1 > {beta2, beta3} and this is known as an (order constrained hypothesis. A major advantage of testing such a hypothesis is that power can be gained and inherently a smaller sample size is needed. This article discusses this gain in sample size reduction, when an increasing number of constraints is included into the hypothesis. The main goal is to present sample-size tables for constrained hypotheses. A sample-size table contains the necessary sample-size at a prespecified power (say, 0.80 for an increasing number of constraints. To obtain sample-size tables, two Monte Carlo simulations were performed, one for ANOVA and one for multiple regression. Three results are salient. First, in an ANOVA the needed sample-size decreases with 30% to 50% when complete ordering of the parameters is taken into account. Second, small deviations from the imposed order have only a minor impact on the power. Third, at the maximum number of constraints, the linear regression results are comparable with the ANOVA results. However, in the case of fewer constraints, ordering the parameters (e.g., beta1 > beta2 results in a higher power than assigning a positive or a negative sign to the parameters (e.g., beta1 > 0.

  5. Autoregressive Prediction with Rolling Mechanism for Time Series Forecasting with Small Sample Size

    Directory of Open Access Journals (Sweden)

    Zhihua Wang

    2014-01-01

    Full Text Available Reasonable prediction makes significant practical sense to stochastic and unstable time series analysis with small or limited sample size. Motivated by the rolling idea in grey theory and the practical relevance of very short-term forecasting or 1-step-ahead prediction, a novel autoregressive (AR prediction approach with rolling mechanism is proposed. In the modeling procedure, a new developed AR equation, which can be used to model nonstationary time series, is constructed in each prediction step. Meanwhile, the data window, for the next step ahead forecasting, rolls on by adding the most recent derived prediction result while deleting the first value of the former used sample data set. This rolling mechanism is an efficient technique for its advantages of improved forecasting accuracy, applicability in the case of limited and unstable data situations, and requirement of little computational effort. The general performance, influence of sample size, nonlinearity dynamic mechanism, and significance of the observed trends, as well as innovation variance, are illustrated and verified with Monte Carlo simulations. The proposed methodology is then applied to several practical data sets, including multiple building settlement sequences and two economic series.

  6. Sample Size in Qualitative Interview Studies: Guided by Information Power.

    Science.gov (United States)

    Malterud, Kirsti; Siersma, Volkert Dirk; Guassora, Ann Dorrit

    2015-11-27

    Sample sizes must be ascertained in qualitative studies like in quantitative studies but not by the same means. The prevailing concept for sample size in qualitative studies is "saturation." Saturation is closely tied to a specific methodology, and the term is inconsistently applied. We propose the concept "information power" to guide adequate sample size for qualitative studies. Information power indicates that the more information the sample holds, relevant for the actual study, the lower amount of participants is needed. We suggest that the size of a sample with sufficient information power depends on (a) the aim of the study, (b) sample specificity, (c) use of established theory, (d) quality of dialogue, and (e) analysis strategy. We present a model where these elements of information and their relevant dimensions are related to information power. Application of this model in the planning and during data collection of a qualitative study is discussed. © The Author(s) 2015.

  7. Computer Graphics Simulations of Sampling Distributions.

    Science.gov (United States)

    Gordon, Florence S.; Gordon, Sheldon P.

    1989-01-01

    Describes the use of computer graphics simulations to enhance student understanding of sampling distributions that arise in introductory statistics. Highlights include the distribution of sample proportions, the distribution of the difference of sample means, the distribution of the difference of sample proportions, and the distribution of sample…

  8. Conservative Sample Size Determination for Repeated Measures Analysis of Covariance.

    Science.gov (United States)

    Morgan, Timothy M; Case, L Douglas

    2013-07-05

    In the design of a randomized clinical trial with one pre and multiple post randomized assessments of the outcome variable, one needs to account for the repeated measures in determining the appropriate sample size. Unfortunately, one seldom has a good estimate of the variance of the outcome measure, let alone the correlations among the measurements over time. We show how sample sizes can be calculated by making conservative assumptions regarding the correlations for a variety of covariance structures. The most conservative choice for the correlation depends on the covariance structure and the number of repeated measures. In the absence of good estimates of the correlations, the sample size is often based on a two-sample t-test, making the 'ultra' conservative and unrealistic assumption that there are zero correlations between the baseline and follow-up measures while at the same time assuming there are perfect correlations between the follow-up measures. Compared to the case of taking a single measurement, substantial savings in sample size can be realized by accounting for the repeated measures, even with very conservative assumptions regarding the parameters of the assumed correlation matrix. Assuming compound symmetry, the sample size from the two-sample t-test calculation can be reduced at least 44%, 56%, and 61% for repeated measures analysis of covariance by taking 2, 3, and 4 follow-up measures, respectively. The results offer a rational basis for determining a fairly conservative, yet efficient, sample size for clinical trials with repeated measures and a baseline value.

  9. The Power of Low Back Pain Trials: A Systematic Review of Power, Sample Size, and Reporting of Sample Size Calculations Over Time, in Trials Published Between 1980 and 2012.

    Science.gov (United States)

    Froud, Robert; Rajendran, Dévan; Patel, Shilpa; Bright, Philip; Bjørkli, Tom; Eldridge, Sandra; Buchbinder, Rachelle; Underwood, Martin

    2017-06-01

    A systematic review of nonspecific low back pain trials published between 1980 and 2012. To explore what proportion of trials have been powered to detect different bands of effect size; whether there is evidence that sample size in low back pain trials has been increasing; what proportion of trial reports include a sample size calculation; and whether likelihood of reporting sample size calculations has increased. Clinical trials should have a sample size sufficient to detect a minimally important difference for a given power and type I error rate. An underpowered trial is one within which probability of type II error is too high. Meta-analyses do not mitigate underpowered trials. Reviewers independently abstracted data on sample size at point of analysis, whether a sample size calculation was reported, and year of publication. Descriptive analyses were used to explore ability to detect effect sizes, and regression analyses to explore the relationship between sample size, or reporting sample size calculations, and time. We included 383 trials. One-third were powered to detect a standardized mean difference of less than 0.5, and 5% were powered to detect less than 0.3. The average sample size was 153 people, which increased only slightly (∼4 people/yr) from 1980 to 2000, and declined slightly (∼4.5 people/yr) from 2005 to 2011 (P pain trials and the reporting of sample size calculations may need to be increased. It may be justifiable to power a trial to detect only large effects in the case of novel interventions. 3.

  10. Power and sample size calculations in the presence of phenotype errors for case/control genetic association studies

    Directory of Open Access Journals (Sweden)

    Finch Stephen J

    2005-04-01

    Full Text Available Abstract Background Phenotype error causes reduction in power to detect genetic association. We present a quantification of phenotype error, also known as diagnostic error, on power and sample size calculations for case-control genetic association studies between a marker locus and a disease phenotype. We consider the classic Pearson chi-square test for independence as our test of genetic association. To determine asymptotic power analytically, we compute the distribution's non-centrality parameter, which is a function of the case and control sample sizes, genotype frequencies, disease prevalence, and phenotype misclassification probabilities. We derive the non-centrality parameter in the presence of phenotype errors and equivalent formulas for misclassification cost (the percentage increase in minimum sample size needed to maintain constant asymptotic power at a fixed significance level for each percentage increase in a given misclassification parameter. We use a linear Taylor Series approximation for the cost of phenotype misclassification to determine lower bounds for the relative costs of misclassifying a true affected (respectively, unaffected as a control (respectively, case. Power is verified by computer simulation. Results Our major findings are that: (i the median absolute difference between analytic power with our method and simulation power was 0.001 and the absolute difference was no larger than 0.011; (ii as the disease prevalence approaches 0, the cost of misclassifying a unaffected as a case becomes infinitely large while the cost of misclassifying an affected as a control approaches 0. Conclusion Our work enables researchers to specifically quantify power loss and minimum sample size requirements in the presence of phenotype errors, thereby allowing for more realistic study design. For most diseases of current interest, verifying that cases are correctly classified is of paramount importance.

  11. Decision Support on Small size Passive Samples

    Directory of Open Access Journals (Sweden)

    Vladimir Popukaylo

    2018-05-01

    Full Text Available A construction technique of adequate mathematical models for small size passive samples, in conditions when classical probabilistic-statis\\-tical methods do not allow obtaining valid conclusions was developed.

  12. Sample Size for Measuring Grammaticality in Preschool Children from Picture-Elicited Language Samples

    Science.gov (United States)

    Eisenberg, Sarita L.; Guo, Ling-Yu

    2015-01-01

    Purpose: The purpose of this study was to investigate whether a shorter language sample elicited with fewer pictures (i.e., 7) would yield a percent grammatical utterances (PGU) score similar to that computed from a longer language sample elicited with 15 pictures for 3-year-old children. Method: Language samples were elicited by asking forty…

  13. Simple and multiple linear regression: sample size considerations.

    Science.gov (United States)

    Hanley, James A

    2016-11-01

    The suggested "two subjects per variable" (2SPV) rule of thumb in the Austin and Steyerberg article is a chance to bring out some long-established and quite intuitive sample size considerations for both simple and multiple linear regression. This article distinguishes two of the major uses of regression models that imply very different sample size considerations, neither served well by the 2SPV rule. The first is etiological research, which contrasts mean Y levels at differing "exposure" (X) values and thus tends to focus on a single regression coefficient, possibly adjusted for confounders. The second research genre guides clinical practice. It addresses Y levels for individuals with different covariate patterns or "profiles." It focuses on the profile-specific (mean) Y levels themselves, estimating them via linear compounds of regression coefficients and covariates. By drawing on long-established closed-form variance formulae that lie beneath the standard errors in multiple regression, and by rearranging them for heuristic purposes, one arrives at quite intuitive sample size considerations for both research genres. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. The Statistics and Mathematics of High Dimension Low Sample Size Asymptotics.

    Science.gov (United States)

    Shen, Dan; Shen, Haipeng; Zhu, Hongtu; Marron, J S

    2016-10-01

    The aim of this paper is to establish several deep theoretical properties of principal component analysis for multiple-component spike covariance models. Our new results reveal an asymptotic conical structure in critical sample eigendirections under the spike models with distinguishable (or indistinguishable) eigenvalues, when the sample size and/or the number of variables (or dimension) tend to infinity. The consistency of the sample eigenvectors relative to their population counterparts is determined by the ratio between the dimension and the product of the sample size with the spike size. When this ratio converges to a nonzero constant, the sample eigenvector converges to a cone, with a certain angle to its corresponding population eigenvector. In the High Dimension, Low Sample Size case, the angle between the sample eigenvector and its population counterpart converges to a limiting distribution. Several generalizations of the multi-spike covariance models are also explored, and additional theoretical results are presented.

  15. The attention-weighted sample-size model of visual short-term memory

    DEFF Research Database (Denmark)

    Smith, Philip L.; Lilburn, Simon D.; Corbett, Elaine A.

    2016-01-01

    exceeded that predicted by the sample-size model for both simultaneously and sequentially presented stimuli. Instead, the set-size effect and the serial position curves with sequential presentation were predicted by an attention-weighted version of the sample-size model, which assumes that one of the items...

  16. Breaking Free of Sample Size Dogma to Perform Innovative Translational Research

    Science.gov (United States)

    Bacchetti, Peter; Deeks, Steven G.; McCune, Joseph M.

    2011-01-01

    Innovative clinical and translational research is often delayed or prevented by reviewers’ expectations that any study performed in humans must be shown in advance to have high statistical power. This supposed requirement is not justifiable and is contradicted by the reality that increasing sample size produces diminishing marginal returns. Studies of new ideas often must start small (sometimes even with an N of 1) because of cost and feasibility concerns, and recent statistical work shows that small sample sizes for such research can produce more projected scientific value per dollar spent than larger sample sizes. Renouncing false dogma about sample size would remove a serious barrier to innovation and translation. PMID:21677197

  17. Efficient inference of population size histories and locus-specific mutation rates from large-sample genomic variation data.

    Science.gov (United States)

    Bhaskar, Anand; Wang, Y X Rachel; Song, Yun S

    2015-02-01

    With the recent increase in study sample sizes in human genetics, there has been growing interest in inferring historical population demography from genomic variation data. Here, we present an efficient inference method that can scale up to very large samples, with tens or hundreds of thousands of individuals. Specifically, by utilizing analytic results on the expected frequency spectrum under the coalescent and by leveraging the technique of automatic differentiation, which allows us to compute gradients exactly, we develop a very efficient algorithm to infer piecewise-exponential models of the historical effective population size from the distribution of sample allele frequencies. Our method is orders of magnitude faster than previous demographic inference methods based on the frequency spectrum. In addition to inferring demography, our method can also accurately estimate locus-specific mutation rates. We perform extensive validation of our method on simulated data and show that it can accurately infer multiple recent epochs of rapid exponential growth, a signal that is difficult to pick up with small sample sizes. Lastly, we use our method to analyze data from recent sequencing studies, including a large-sample exome-sequencing data set of tens of thousands of individuals assayed at a few hundred genic regions. © 2015 Bhaskar et al.; Published by Cold Spring Harbor Laboratory Press.

  18. The role of micro size computing clusters for small physics groups

    International Nuclear Information System (INIS)

    Shevel, A Y

    2014-01-01

    A small physics group (3-15 persons) might use a number of computing facilities for the analysis/simulation, developing/testing, teaching. It is discussed different types of computing facilities: collaboration computing facilities, group local computing cluster (including colocation), cloud computing. The author discuss the growing variety of different computing options for small groups and does emphasize the role of the group owned computing cluster of micro size.

  19. Sample Size and Saturation in PhD Studies Using Qualitative Interviews

    Directory of Open Access Journals (Sweden)

    Mark Mason

    2010-08-01

    Full Text Available A number of issues can affect sample size in qualitative research; however, the guiding principle should be the concept of saturation. This has been explored in detail by a number of authors but is still hotly debated, and some say little understood. A sample of PhD studies using qualitative approaches, and qualitative interviews as the method of data collection was taken from theses.com and contents analysed for their sample sizes. Five hundred and sixty studies were identified that fitted the inclusion criteria. Results showed that the mean sample size was 31; however, the distribution was non-random, with a statistically significant proportion of studies, presenting sample sizes that were multiples of ten. These results are discussed in relation to saturation. They suggest a pre-meditated approach that is not wholly congruent with the principles of qualitative research. URN: urn:nbn:de:0114-fqs100387

  20. Rational Arithmetic Mathematica Functions to Evaluate the Two-Sided One Sample K-S Cumulative Sampling Distribution

    Directory of Open Access Journals (Sweden)

    J. Randall Brown

    2007-06-01

    Full Text Available One of the most widely used goodness-of-fit tests is the two-sided one sample Kolmogorov-Smirnov (K-S test which has been implemented by many computer statistical software packages. To calculate a two-sided p value (evaluate the cumulative sampling distribution, these packages use various methods including recursion formulae, limiting distributions, and approximations of unknown accuracy developed over thirty years ago. Based on an extensive literature search for the two-sided one sample K-S test, this paper identifies an exact formula for sample sizes up to 31, six recursion formulae, and one matrix formula that can be used to calculate a p value. To ensure accurate calculation by avoiding catastrophic cancelation and eliminating rounding error, each of these formulae is implemented in rational arithmetic. For the six recursion formulae and the matrix formula, computational experience for sample sizes up to 500 shows that computational times are increasing functions of both the sample size and the number of digits in the numerator and denominator integers of the rational number test statistic. The computational times of the seven formulae vary immensely but the Durbin recursion formula is almost always the fastest. Linear search is used to calculate the inverse of the cumulative sampling distribution (find the confidence interval half-width and tables of calculated half-widths are presented for sample sizes up to 500. Using calculated half-widths as input, computational times for the fastest formula, the Durbin recursion formula, are given for sample sizes up to two thousand.

  1. An algorithm to improve sampling efficiency for uncertainty propagation using sampling based method

    International Nuclear Information System (INIS)

    Campolina, Daniel; Lima, Paulo Rubens I.; Pereira, Claubia; Veloso, Maria Auxiliadora F.

    2015-01-01

    Sample size and computational uncertainty were varied in order to investigate sample efficiency and convergence of the sampling based method for uncertainty propagation. Transport code MCNPX was used to simulate a LWR model and allow the mapping, from uncertain inputs of the benchmark experiment, to uncertain outputs. Random sampling efficiency was improved through the use of an algorithm for selecting distributions. Mean range, standard deviation range and skewness were verified in order to obtain a better representation of uncertainty figures. Standard deviation of 5 pcm in the propagated uncertainties for 10 n-samples replicates was adopted as convergence criterion to the method. Estimation of 75 pcm uncertainty on reactor k eff was accomplished by using sample of size 93 and computational uncertainty of 28 pcm to propagate 1σ uncertainty of burnable poison radius. For a fixed computational time, in order to reduce the variance of the uncertainty propagated, it was found, for the example under investigation, it is preferable double the sample size than double the amount of particles followed by Monte Carlo process in MCNPX code. (author)

  2. Sample size allocation in multiregional equivalence studies.

    Science.gov (United States)

    Liao, Jason J Z; Yu, Ziji; Li, Yulan

    2018-06-17

    With the increasing globalization of drug development, the multiregional clinical trial (MRCT) has gained extensive use. The data from MRCTs could be accepted by regulatory authorities across regions and countries as the primary sources of evidence to support global marketing drug approval simultaneously. The MRCT can speed up patient enrollment and drug approval, and it makes the effective therapies available to patients all over the world simultaneously. However, there are many challenges both operationally and scientifically in conducting a drug development globally. One of many important questions to answer for the design of a multiregional study is how to partition sample size into each individual region. In this paper, two systematic approaches are proposed for the sample size allocation in a multiregional equivalence trial. A numerical evaluation and a biosimilar trial are used to illustrate the characteristics of the proposed approaches. Copyright © 2018 John Wiley & Sons, Ltd.

  3. Sampling strategies for estimating brook trout effective population size

    Science.gov (United States)

    Andrew R. Whiteley; Jason A. Coombs; Mark Hudy; Zachary Robinson; Keith H. Nislow; Benjamin H. Letcher

    2012-01-01

    The influence of sampling strategy on estimates of effective population size (Ne) from single-sample genetic methods has not been rigorously examined, though these methods are increasingly used. For headwater salmonids, spatially close kin association among age-0 individuals suggests that sampling strategy (number of individuals and location from...

  4. Algorithm for computing significance levels using the Kolmogorov-Smirnov statistic and valid for both large and small samples

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.E.; Fields, D.E.

    1983-10-01

    The KSTEST code presented here is designed to perform the Kolmogorov-Smirnov one-sample test. The code may be used as a stand-alone program or the principal subroutines may be excerpted and used to service other programs. The Kolmogorov-Smirnov one-sample test is a nonparametric goodness-of-fit test. A number of codes to perform this test are in existence, but they suffer from the inability to provide meaningful results in the case of small sample sizes (number of values less than or equal to 80). The KSTEST code overcomes this inadequacy by using two distinct algorithms. If the sample size is greater than 80, an asymptotic series developed by Smirnov is evaluated. If the sample size is 80 or less, a table of values generated by Birnbaum is referenced. Valid results can be obtained from KSTEST when the sample contains from 3 to 300 data points. The program was developed on a Digital Equipment Corporation PDP-10 computer using the FORTRAN-10 language. The code size is approximately 450 card images and the typical CPU execution time is 0.19 s.

  5. Sample Size Induced Brittle-to-Ductile Transition of Single-Crystal Aluminum Nitride

    Science.gov (United States)

    2015-08-01

    ARL-RP-0528 ● AUG 2015 US Army Research Laboratory Sample Size Induced Brittle-to- Ductile Transition of Single-Crystal Aluminum...originator. ARL-RP-0528 ● AUG 2015 US Army Research Laboratory Sample Size Induced Brittle-to- Ductile Transition of Single-Crystal...Sample Size Induced Brittle-to- Ductile Transition of Single-Crystal Aluminum Nitride 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT

  6. Sample size determination for logistic regression on a logit-normal distribution.

    Science.gov (United States)

    Kim, Seongho; Heath, Elisabeth; Heilbrun, Lance

    2017-06-01

    Although the sample size for simple logistic regression can be readily determined using currently available methods, the sample size calculation for multiple logistic regression requires some additional information, such as the coefficient of determination ([Formula: see text]) of a covariate of interest with other covariates, which is often unavailable in practice. The response variable of logistic regression follows a logit-normal distribution which can be generated from a logistic transformation of a normal distribution. Using this property of logistic regression, we propose new methods of determining the sample size for simple and multiple logistic regressions using a normal transformation of outcome measures. Simulation studies and a motivating example show several advantages of the proposed methods over the existing methods: (i) no need for [Formula: see text] for multiple logistic regression, (ii) available interim or group-sequential designs, and (iii) much smaller required sample size.

  7. Brachytherapy dose-volume histogram computations using optimized stratified sampling methods

    International Nuclear Information System (INIS)

    Karouzakis, K.; Lahanas, M.; Milickovic, N.; Giannouli, S.; Baltas, D.; Zamboglou, N.

    2002-01-01

    A stratified sampling method for the efficient repeated computation of dose-volume histograms (DVHs) in brachytherapy is presented as used for anatomy based brachytherapy optimization methods. The aim of the method is to reduce the number of sampling points required for the calculation of DVHs for the body and the PTV. From the DVHs are derived the quantities such as Conformity Index COIN and COIN integrals. This is achieved by using partial uniform distributed sampling points with a density in each region obtained from a survey of the gradients or the variance of the dose distribution in these regions. The shape of the sampling regions is adapted to the patient anatomy and the shape and size of the implant. For the application of this method a single preprocessing step is necessary which requires only a few seconds. Ten clinical implants were used to study the appropriate number of sampling points, given a required accuracy for quantities such as cumulative DVHs, COIN indices and COIN integrals. We found that DVHs of very large tissue volumes surrounding the PTV, and also COIN distributions, can be obtained using a factor of 5-10 times smaller the number of sampling points in comparison with uniform distributed points

  8. Sample size reassessment for a two-stage design controlling the false discovery rate.

    Science.gov (United States)

    Zehetmayer, Sonja; Graf, Alexandra C; Posch, Martin

    2015-11-01

    Sample size calculations for gene expression microarray and NGS-RNA-Seq experiments are challenging because the overall power depends on unknown quantities as the proportion of true null hypotheses and the distribution of the effect sizes under the alternative. We propose a two-stage design with an adaptive interim analysis where these quantities are estimated from the interim data. The second stage sample size is chosen based on these estimates to achieve a specific overall power. The proposed procedure controls the power in all considered scenarios except for very low first stage sample sizes. The false discovery rate (FDR) is controlled despite of the data dependent choice of sample size. The two-stage design can be a useful tool to determine the sample size of high-dimensional studies if in the planning phase there is high uncertainty regarding the expected effect sizes and variability.

  9. Nomogram for sample size calculation on a straightforward basis for the kappa statistic.

    Science.gov (United States)

    Hong, Hyunsook; Choi, Yunhee; Hahn, Seokyung; Park, Sue Kyung; Park, Byung-Joo

    2014-09-01

    Kappa is a widely used measure of agreement. However, it may not be straightforward in some situation such as sample size calculation due to the kappa paradox: high agreement but low kappa. Hence, it seems reasonable in sample size calculation that the level of agreement under a certain marginal prevalence is considered in terms of a simple proportion of agreement rather than a kappa value. Therefore, sample size formulae and nomograms using a simple proportion of agreement rather than a kappa under certain marginal prevalences are proposed. A sample size formula was derived using the kappa statistic under the common correlation model and goodness-of-fit statistic. The nomogram for the sample size formula was developed using SAS 9.3. The sample size formulae using a simple proportion of agreement instead of a kappa statistic and nomograms to eliminate the inconvenience of using a mathematical formula were produced. A nomogram for sample size calculation with a simple proportion of agreement should be useful in the planning stages when the focus of interest is on testing the hypothesis of interobserver agreement involving two raters and nominal outcome measures. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Sample size optimization in nuclear material control. 1

    International Nuclear Information System (INIS)

    Gladitz, J.

    1982-01-01

    Equations have been derived and exemplified which allow the determination of the minimum variables sample size for given false alarm and detection probabilities of nuclear material losses and diversions, respectively. (author)

  11. Impact of shoe size in a sample of elderly individuals

    Directory of Open Access Journals (Sweden)

    Daniel López-López

    Full Text Available Summary Introduction: The use of an improper shoe size is common in older people and is believed to have a detrimental effect on the quality of life related to foot health. The objective is to describe and compare, in a sample of participants, the impact of shoes that fit properly or improperly, as well as analyze the scores related to foot health and health overall. Method: A sample of 64 participants, with a mean age of 75.3±7.9 years, attended an outpatient center where self-report data was recorded, the measurements of the size of the feet and footwear were determined and the scores compared between the group that wears the correct size of shoes and another group of individuals who do not wear the correct size of shoes, using the Spanish version of the Foot Health Status Questionnaire. Results: The group wearing an improper shoe size showed poorer quality of life regarding overall health and specifically foot health. Differences between groups were evaluated using a t-test for independent samples resulting statistically significant (p<0.05 for the dimension of pain, function, footwear, overall foot health, and social function. Conclusion: Inadequate shoe size has a significant negative impact on quality of life related to foot health. The degree of negative impact seems to be associated with age, sex, and body mass index (BMI.

  12. Cloud Computing Adoption Business Model Factors: Does Enterprise Size Matter?

    OpenAIRE

    Bogataj Habjan, Kristina; Pucihar, Andreja

    2017-01-01

    This paper presents the results of research investigating the impact of business model factors on cloud computing adoption. The introduced research model consists of 40 cloud computing business model factors, grouped into eight factor groups. Their impact and importance for cloud computing adoption were investigated among enterpirses in Slovenia. Furthermore, differences in opinion according to enterprise size were investigated. Research results show no statistically significant impacts of in...

  13. Threshold-dependent sample sizes for selenium assessment with stream fish tissue

    Science.gov (United States)

    Hitt, Nathaniel P.; Smith, David R.

    2015-01-01

    Natural resource managers are developing assessments of selenium (Se) contamination in freshwater ecosystems based on fish tissue concentrations. We evaluated the effects of sample size (i.e., number of fish per site) on the probability of correctly detecting mean whole-body Se values above a range of potential management thresholds. We modeled Se concentrations as gamma distributions with shape and scale parameters fitting an empirical mean-to-variance relationship in data from southwestern West Virginia, USA (63 collections, 382 individuals). We used parametric bootstrapping techniques to calculate statistical power as the probability of detecting true mean concentrations up to 3 mg Se/kg above management thresholds ranging from 4 to 8 mg Se/kg. Sample sizes required to achieve 80% power varied as a function of management thresholds and Type I error tolerance (α). Higher thresholds required more samples than lower thresholds because populations were more heterogeneous at higher mean Se levels. For instance, to assess a management threshold of 4 mg Se/kg, a sample of eight fish could detect an increase of approximately 1 mg Se/kg with 80% power (given α = 0.05), but this sample size would be unable to detect such an increase from a management threshold of 8 mg Se/kg with more than a coin-flip probability. Increasing α decreased sample size requirements to detect above-threshold mean Se concentrations with 80% power. For instance, at an α-level of 0.05, an 8-fish sample could detect an increase of approximately 2 units above a threshold of 8 mg Se/kg with 80% power, but when α was relaxed to 0.2, this sample size was more sensitive to increasing mean Se concentrations, allowing detection of an increase of approximately 1.2 units with equivalent power. Combining individuals into 2- and 4-fish composite samples for laboratory analysis did not decrease power because the reduced number of laboratory samples was compensated for by increased

  14. Detecting spatial structures in throughfall data: The effect of extent, sample size, sampling design, and variogram estimation method

    Science.gov (United States)

    Voss, Sebastian; Zimmermann, Beate; Zimmermann, Alexander

    2016-09-01

    In the last decades, an increasing number of studies analyzed spatial patterns in throughfall by means of variograms. The estimation of the variogram from sample data requires an appropriate sampling scheme: most importantly, a large sample and a layout of sampling locations that often has to serve both variogram estimation and geostatistical prediction. While some recommendations on these aspects exist, they focus on Gaussian data and high ratios of the variogram range to the extent of the study area. However, many hydrological data, and throughfall data in particular, do not follow a Gaussian distribution. In this study, we examined the effect of extent, sample size, sampling design, and calculation method on variogram estimation of throughfall data. For our investigation, we first generated non-Gaussian random fields based on throughfall data with large outliers. Subsequently, we sampled the fields with three extents (plots with edge lengths of 25 m, 50 m, and 100 m), four common sampling designs (two grid-based layouts, transect and random sampling) and five sample sizes (50, 100, 150, 200, 400). We then estimated the variogram parameters by method-of-moments (non-robust and robust estimators) and residual maximum likelihood. Our key findings are threefold. First, the choice of the extent has a substantial influence on the estimation of the variogram. A comparatively small ratio of the extent to the correlation length is beneficial for variogram estimation. Second, a combination of a minimum sample size of 150, a design that ensures the sampling of small distances and variogram estimation by residual maximum likelihood offers a good compromise between accuracy and efficiency. Third, studies relying on method-of-moments based variogram estimation may have to employ at least 200 sampling points for reliable variogram estimates. These suggested sample sizes exceed the number recommended by studies dealing with Gaussian data by up to 100 %. Given that most previous

  15. Optimum sample size to estimate mean parasite abundance in fish parasite surveys

    Directory of Open Access Journals (Sweden)

    Shvydka S.

    2018-03-01

    Full Text Available To reach ethically and scientifically valid mean abundance values in parasitological and epidemiological studies this paper considers analytic and simulation approaches for sample size determination. The sample size estimation was carried out by applying mathematical formula with predetermined precision level and parameter of the negative binomial distribution estimated from the empirical data. A simulation approach to optimum sample size determination aimed at the estimation of true value of the mean abundance and its confidence interval (CI was based on the Bag of Little Bootstraps (BLB. The abundance of two species of monogenean parasites Ligophorus cephali and L. mediterraneus from Mugil cephalus across the Azov-Black Seas localities were subjected to the analysis. The dispersion pattern of both helminth species could be characterized as a highly aggregated distribution with the variance being substantially larger than the mean abundance. The holistic approach applied here offers a wide range of appropriate methods in searching for the optimum sample size and the understanding about the expected precision level of the mean. Given the superior performance of the BLB relative to formulae with its few assumptions, the bootstrap procedure is the preferred method. Two important assessments were performed in the present study: i based on CIs width a reasonable precision level for the mean abundance in parasitological surveys of Ligophorus spp. could be chosen between 0.8 and 0.5 with 1.6 and 1x mean of the CIs width, and ii the sample size equal 80 or more host individuals allows accurate and precise estimation of mean abundance. Meanwhile for the host sample size in range between 25 and 40 individuals, the median estimates showed minimal bias but the sampling distribution skewed to the low values; a sample size of 10 host individuals yielded to unreliable estimates.

  16. Sample size for post-marketing safety studies based on historical controls.

    Science.gov (United States)

    Wu, Yu-te; Makuch, Robert W

    2010-08-01

    As part of a drug's entire life cycle, post-marketing studies are an important part in the identification of rare, serious adverse events. Recently, the US Food and Drug Administration (FDA) has begun to implement new post-marketing safety mandates as a consequence of increased emphasis on safety. The purpose of this research is to provide exact sample size formula for the proposed hybrid design, based on a two-group cohort study with incorporation of historical external data. Exact sample size formula based on the Poisson distribution is developed, because the detection of rare events is our outcome of interest. Performance of exact method is compared to its approximate large-sample theory counterpart. The proposed hybrid design requires a smaller sample size compared to the standard, two-group prospective study design. In addition, the exact method reduces the number of subjects required in the treatment group by up to 30% compared to the approximate method for the study scenarios examined. The proposed hybrid design satisfies the advantages and rationale of the two-group design with smaller sample sizes generally required. 2010 John Wiley & Sons, Ltd.

  17. Enhancing sampling design in mist-net bat surveys by accounting for sample size optimization

    OpenAIRE

    Trevelin, Leonardo Carreira; Novaes, Roberto Leonan Morim; Colas-Rosas, Paul François; Benathar, Thayse Cristhina Melo; Peres, Carlos A.

    2017-01-01

    The advantages of mist-netting, the main technique used in Neotropical bat community studies to date, include logistical implementation, standardization and sampling representativeness. Nonetheless, study designs still have to deal with issues of detectability related to how different species behave and use the environment. Yet there is considerable sampling heterogeneity across available studies in the literature. Here, we approach the problem of sample size optimization. We evaluated the co...

  18. Determining Sample Size for Accurate Estimation of the Squared Multiple Correlation Coefficient.

    Science.gov (United States)

    Algina, James; Olejnik, Stephen

    2000-01-01

    Discusses determining sample size for estimation of the squared multiple correlation coefficient and presents regression equations that permit determination of the sample size for estimating this parameter for up to 20 predictor variables. (SLD)

  19. Sample size in psychological research over the past 30 years.

    Science.gov (United States)

    Marszalek, Jacob M; Barber, Carolyn; Kohlhart, Julie; Holmes, Cooper B

    2011-04-01

    The American Psychological Association (APA) Task Force on Statistical Inference was formed in 1996 in response to a growing body of research demonstrating methodological issues that threatened the credibility of psychological research, and made recommendations to address them. One issue was the small, even dramatically inadequate, size of samples used in studies published by leading journals. The present study assessed the progress made since the Task Force's final report in 1999. Sample sizes reported in four leading APA journals in 1955, 1977, 1995, and 2006 were compared using nonparametric statistics, while data from the last two waves were fit to a hierarchical generalized linear growth model for more in-depth analysis. Overall, results indicate that the recommendations for increasing sample sizes have not been integrated in core psychological research, although results slightly vary by field. This and other implications are discussed in the context of current methodological critique and practice.

  20. A flexible method for multi-level sample size determination

    International Nuclear Information System (INIS)

    Lu, Ming-Shih; Sanborn, J.B.; Teichmann, T.

    1997-01-01

    This paper gives a flexible method to determine sample sizes for both systematic and random error models (this pertains to sampling problems in nuclear safeguard questions). In addition, the method allows different attribute rejection limits. The new method could assist achieving a higher detection probability and enhance inspection effectiveness

  1. Finite mixture models for the computation of isotope ratios in mixed isotopic samples

    Science.gov (United States)

    Koffler, Daniel; Laaha, Gregor; Leisch, Friedrich; Kappel, Stefanie; Prohaska, Thomas

    2013-04-01

    Finite mixture models have been used for more than 100 years, but have seen a real boost in popularity over the last two decades due to the tremendous increase in available computing power. The areas of application of mixture models range from biology and medicine to physics, economics and marketing. These models can be applied to data where observations originate from various groups and where group affiliations are not known, as is the case for multiple isotope ratios present in mixed isotopic samples. Recently, the potential of finite mixture models for the computation of 235U/238U isotope ratios from transient signals measured in individual (sub-)µm-sized particles by laser ablation - multi-collector - inductively coupled plasma mass spectrometry (LA-MC-ICPMS) was demonstrated by Kappel et al. [1]. The particles, which were deposited on the same substrate, were certified with respect to their isotopic compositions. Here, we focus on the statistical model and its application to isotope data in ecogeochemistry. Commonly applied evaluation approaches for mixed isotopic samples are time-consuming and are dependent on the judgement of the analyst. Thus, isotopic compositions may be overlooked due to the presence of more dominant constituents. Evaluation using finite mixture models can be accomplished unsupervised and automatically. The models try to fit several linear models (regression lines) to subgroups of data taking the respective slope as estimation for the isotope ratio. The finite mixture models are parameterised by: • The number of different ratios. • Number of points belonging to each ratio-group. • The ratios (i.e. slopes) of each group. Fitting of the parameters is done by maximising the log-likelihood function using an iterative expectation-maximisation (EM) algorithm. In each iteration step, groups of size smaller than a control parameter are dropped; thereby the number of different ratios is determined. The analyst only influences some control

  2. Sample Size Calculation for Controlling False Discovery Proportion

    Directory of Open Access Journals (Sweden)

    Shulian Shang

    2012-01-01

    Full Text Available The false discovery proportion (FDP, the proportion of incorrect rejections among all rejections, is a direct measure of abundance of false positive findings in multiple testing. Many methods have been proposed to control FDP, but they are too conservative to be useful for power analysis. Study designs for controlling the mean of FDP, which is false discovery rate, have been commonly used. However, there has been little attempt to design study with direct FDP control to achieve certain level of efficiency. We provide a sample size calculation method using the variance formula of the FDP under weak-dependence assumptions to achieve the desired overall power. The relationship between design parameters and sample size is explored. The adequacy of the procedure is assessed by simulation. We illustrate the method using estimated correlations from a prostate cancer dataset.

  3. A normative inference approach for optimal sample sizes in decisions from experience

    Science.gov (United States)

    Ostwald, Dirk; Starke, Ludger; Hertwig, Ralph

    2015-01-01

    “Decisions from experience” (DFE) refers to a body of work that emerged in research on behavioral decision making over the last decade. One of the major experimental paradigms employed to study experience-based choice is the “sampling paradigm,” which serves as a model of decision making under limited knowledge about the statistical structure of the world. In this paradigm respondents are presented with two payoff distributions, which, in contrast to standard approaches in behavioral economics, are specified not in terms of explicit outcome-probability information, but by the opportunity to sample outcomes from each distribution without economic consequences. Participants are encouraged to explore the distributions until they feel confident enough to decide from which they would prefer to draw from in a final trial involving real monetary payoffs. One commonly employed measure to characterize the behavior of participants in the sampling paradigm is the sample size, that is, the number of outcome draws which participants choose to obtain from each distribution prior to terminating sampling. A natural question that arises in this context concerns the “optimal” sample size, which could be used as a normative benchmark to evaluate human sampling behavior in DFE. In this theoretical study, we relate the DFE sampling paradigm to the classical statistical decision theoretic literature and, under a probabilistic inference assumption, evaluate optimal sample sizes for DFE. In our treatment we go beyond analytically established results by showing how the classical statistical decision theoretic framework can be used to derive optimal sample sizes under arbitrary, but numerically evaluable, constraints. Finally, we critically evaluate the value of deriving optimal sample sizes under this framework as testable predictions for the experimental study of sampling behavior in DFE. PMID:26441720

  4. Computation of Effect Size for Moderating Effects of Categorical Variables in Multiple Regression

    Science.gov (United States)

    Aguinis, Herman; Pierce, Charles A.

    2006-01-01

    The computation and reporting of effect size estimates is becoming the norm in many journals in psychology and related disciplines. Despite the increased importance of effect sizes, researchers may not report them or may report inaccurate values because of a lack of appropriate computational tools. For instance, Pierce, Block, and Aguinis (2004)…

  5. How accurate are adolescents in portion-size estimation using the computer tool Young Adolescents' Nutrition Assessment on Computer (YANA-C)?

    Science.gov (United States)

    Vereecken, Carine; Dohogne, Sophie; Covents, Marc; Maes, Lea

    2010-06-01

    Computer-administered questionnaires have received increased attention for large-scale population research on nutrition. In Belgium-Flanders, Young Adolescents' Nutrition Assessment on Computer (YANA-C) has been developed. In this tool, standardised photographs are available to assist in portion-size estimation. The purpose of the present study is to assess how accurate adolescents are in estimating portion sizes of food using YANA-C. A convenience sample, aged 11-17 years, estimated the amounts of ten commonly consumed foods (breakfast cereals, French fries, pasta, rice, apple sauce, carrots and peas, crisps, creamy velouté, red cabbage, and peas). Two procedures were followed: (1) short-term recall: adolescents (n 73) self-served their usual portions of the ten foods and estimated the amounts later the same day; (2) real-time perception: adolescents (n 128) estimated two sets (different portions) of pre-weighed portions displayed near the computer. Self-served portions were, on average, 8 % underestimated; significant underestimates were found for breakfast cereals, French fries, peas, and carrots and peas. Spearman's correlations between the self-served and estimated weights varied between 0.51 and 0.84, with an average of 0.72. The kappa statistics were moderate (>0.4) for all but one item. Pre-weighed portions were, on average, 15 % underestimated, with significant underestimates for fourteen of the twenty portions. Photographs of food items can serve as a good aid in ranking subjects; however, to assess the actual intake at a group level, underestimation must be considered.

  6. Rock sampling. [method for controlling particle size distribution

    Science.gov (United States)

    Blum, P. (Inventor)

    1971-01-01

    A method for sampling rock and other brittle materials and for controlling resultant particle sizes is described. The method involves cutting grooves in the rock surface to provide a grouping of parallel ridges and subsequently machining the ridges to provide a powder specimen. The machining step may comprise milling, drilling, lathe cutting or the like; but a planing step is advantageous. Control of the particle size distribution is effected primarily by changing the height and width of these ridges. This control exceeds that obtainable by conventional grinding.

  7. Effects of sample size on the second magnetization peak in ...

    Indian Academy of Sciences (India)

    8+ crystals are observed at low temperatures, above the temperature where the SMP totally disappears. In particular, the onset of the SMP shifts to lower fields as the sample size decreases - a result that could be interpreted as a size effect in ...

  8. Sample size for estimation of the Pearson correlation coefficient in cherry tomato tests

    Directory of Open Access Journals (Sweden)

    Bruno Giacomini Sari

    2017-09-01

    Full Text Available ABSTRACT: The aim of this study was to determine the required sample size for estimation of the Pearson coefficient of correlation between cherry tomato variables. Two uniformity tests were set up in a protected environment in the spring/summer of 2014. The observed variables in each plant were mean fruit length, mean fruit width, mean fruit weight, number of bunches, number of fruits per bunch, number of fruits, and total weight of fruits, with calculation of the Pearson correlation matrix between them. Sixty eight sample sizes were planned for one greenhouse and 48 for another, with the initial sample size of 10 plants, and the others were obtained by adding five plants. For each planned sample size, 3000 estimates of the Pearson correlation coefficient were obtained through bootstrap re-samplings with replacement. The sample size for each correlation coefficient was determined when the 95% confidence interval amplitude value was less than or equal to 0.4. Obtaining estimates of the Pearson correlation coefficient with high precision is difficult for parameters with a weak linear relation. Accordingly, a larger sample size is necessary to estimate them. Linear relations involving variables dealing with size and number of fruits per plant have less precision. To estimate the coefficient of correlation between productivity variables of cherry tomato, with a confidence interval of 95% equal to 0.4, it is necessary to sample 275 plants in a 250m² greenhouse, and 200 plants in a 200m² greenhouse.

  9. Effect of sample size on bias correction performance

    Science.gov (United States)

    Reiter, Philipp; Gutjahr, Oliver; Schefczyk, Lukas; Heinemann, Günther; Casper, Markus C.

    2014-05-01

    The output of climate models often shows a bias when compared to observed data, so that a preprocessing is necessary before using it as climate forcing in impact modeling (e.g. hydrology, species distribution). A common bias correction method is the quantile matching approach, which adapts the cumulative distribution function of the model output to the one of the observed data by means of a transfer function. Especially for precipitation we expect the bias correction performance to strongly depend on sample size, i.e. the length of the period used for calibration of the transfer function. We carry out experiments using the precipitation output of ten regional climate model (RCM) hindcast runs from the EU-ENSEMBLES project and the E-OBS observational dataset for the period 1961 to 2000. The 40 years are split into a 30 year calibration period and a 10 year validation period. In the first step, for each RCM transfer functions are set up cell-by-cell, using the complete 30 year calibration period. The derived transfer functions are applied to the validation period of the respective RCM precipitation output and the mean absolute errors in reference to the observational dataset are calculated. These values are treated as "best fit" for the respective RCM. In the next step, this procedure is redone using subperiods out of the 30 year calibration period. The lengths of these subperiods are reduced from 29 years down to a minimum of 1 year, only considering subperiods of consecutive years. This leads to an increasing number of repetitions for smaller sample sizes (e.g. 2 for a length of 29 years). In the last step, the mean absolute errors are statistically tested against the "best fit" of the respective RCM to compare the performances. In order to analyze if the intensity of the effect of sample size depends on the chosen correction method, four variations of the quantile matching approach (PTF, QUANT/eQM, gQM, GQM) are applied in this study. The experiments are further

  10. Accuracy of computed tomography in determining pancreatic cancer tumor size

    International Nuclear Information System (INIS)

    Aoki, Kazunori; Okada, Shuichi; Moriyama, Noriyuki

    1994-01-01

    We compared tumor sizes determined by computed tomography (CT) with those of the resected specimens in 26 patients with pancreatic cancer in order to clarify whether or not the size of a pancreatic tumor can be accurately determined by CT. From the precontrast, postcontrast and arterial dominant phases of dynamic CT, the arterial dominant phase was found to yield the highest correlation between CT measured tumor size and that of the resected specimens (p<0.01). The correlation coefficient was, however, not high (r=0.67). CT alone may therefore be insufficient to determine tumor size in pancreatic cancer accurately. (author)

  11. Overestimation of test performance by ROC analysis: Effect of small sample size

    International Nuclear Information System (INIS)

    Seeley, G.W.; Borgstrom, M.C.; Patton, D.D.; Myers, K.J.; Barrett, H.H.

    1984-01-01

    New imaging systems are often observer-rated by ROC techniques. For practical reasons the number of different images, or sample size (SS), is kept small. Any systematic bias due to small SS would bias system evaluation. The authors set about to determine whether the area under the ROC curve (AUC) would be systematically biased by small SS. Monte Carlo techniques were used to simulate observer performance in distinguishing signal (SN) from noise (N) on a 6-point scale; P(SN) = P(N) = .5. Four sample sizes (15, 25, 50 and 100 each of SN and N), three ROC slopes (0.8, 1.0 and 1.25), and three intercepts (0.8, 1.0 and 1.25) were considered. In each of the 36 combinations of SS, slope and intercept, 2000 runs were simulated. Results showed a systematic bias: the observed AUC exceeded the expected AUC in every one of the 36 combinations for all sample sizes, with the smallest sample sizes having the largest bias. This suggests that evaluations of imaging systems using ROC curves based on small sample size systematically overestimate system performance. The effect is consistent but subtle (maximum 10% of AUC standard deviation), and is probably masked by the s.d. in most practical settings. Although there is a statistically significant effect (F = 33.34, P<0.0001) due to sample size, none was found for either the ROC curve slope or intercept. Overestimation of test performance by small SS seems to be an inherent characteristic of the ROC technique that has not previously been described

  12. Test of methods for retrospective activity size distribution determination from filter samples

    International Nuclear Information System (INIS)

    Meisenberg, Oliver; Tschiersch, Jochen

    2015-01-01

    Determining the activity size distribution of radioactive aerosol particles requires sophisticated and heavy equipment, which makes measurements at large number of sites difficult and expensive. Therefore three methods for a retrospective determination of size distributions from aerosol filter samples in the laboratory were tested for their applicability. Extraction into a carrier liquid with subsequent nebulisation showed size distributions with a slight but correctable bias towards larger diameters compared with the original size distribution. Yields in the order of magnitude of 1% could be achieved. Sonication-assisted extraction into a carrier liquid caused a coagulation mode to appear in the size distribution. Sonication-assisted extraction into the air did not show acceptable results due to small yields. The method of extraction into a carrier liquid without sonication was applied to aerosol samples from Chernobyl in order to calculate inhalation dose coefficients for 137 Cs based on the individual size distribution. The effective dose coefficient is about half of that calculated with a default reference size distribution. - Highlights: • Activity size distributions can be recovered after aerosol sampling on filters. • Extraction into a carrier liquid and subsequent nebulisation is appropriate. • This facilitates the determination of activity size distributions for individuals. • Size distributions from this method can be used for individual dose coefficients. • Dose coefficients were calculated for the workers at the new Chernobyl shelter

  13. Caution regarding the choice of standard deviations to guide sample size calculations in clinical trials.

    Science.gov (United States)

    Chen, Henian; Zhang, Nanhua; Lu, Xiaosun; Chen, Sophie

    2013-08-01

    The method used to determine choice of standard deviation (SD) is inadequately reported in clinical trials. Underestimations of the population SD may result in underpowered clinical trials. This study demonstrates how using the wrong method to determine population SD can lead to inaccurate sample sizes and underpowered studies, and offers recommendations to maximize the likelihood of achieving adequate statistical power. We review the practice of reporting sample size and its effect on the power of trials published in major journals. Simulated clinical trials were used to compare the effects of different methods of determining SD on power and sample size calculations. Prior to 1996, sample size calculations were reported in just 1%-42% of clinical trials. This proportion increased from 38% to 54% after the initial Consolidated Standards of Reporting Trials (CONSORT) was published in 1996, and from 64% to 95% after the revised CONSORT was published in 2001. Nevertheless, underpowered clinical trials are still common. Our simulated data showed that all minimal and 25th-percentile SDs fell below 44 (the population SD), regardless of sample size (from 5 to 50). For sample sizes 5 and 50, the minimum sample SDs underestimated the population SD by 90.7% and 29.3%, respectively. If only one sample was available, there was less than 50% chance that the actual power equaled or exceeded the planned power of 80% for detecting a median effect size (Cohen's d = 0.5) when using the sample SD to calculate the sample size. The proportions of studies with actual power of at least 80% were about 95%, 90%, 85%, and 80% when we used the larger SD, 80% upper confidence limit (UCL) of SD, 70% UCL of SD, and 60% UCL of SD to calculate the sample size, respectively. When more than one sample was available, the weighted average SD resulted in about 50% of trials being underpowered; the proportion of trials with power of 80% increased from 90% to 100% when the 75th percentile and the

  14. Sample sizes and model comparison metrics for species distribution models

    Science.gov (United States)

    B.B. Hanberry; H.S. He; D.C. Dey

    2012-01-01

    Species distribution models use small samples to produce continuous distribution maps. The question of how small a sample can be to produce an accurate model generally has been answered based on comparisons to maximum sample sizes of 200 observations or fewer. In addition, model comparisons often are made with the kappa statistic, which has become controversial....

  15. Influence of Sample Size on Automatic Positional Accuracy Assessment Methods for Urban Areas

    Directory of Open Access Journals (Sweden)

    Francisco J. Ariza-López

    2018-05-01

    Full Text Available In recent years, new approaches aimed to increase the automation level of positional accuracy assessment processes for spatial data have been developed. However, in such cases, an aspect as significant as sample size has not yet been addressed. In this paper, we study the influence of sample size when estimating the planimetric positional accuracy of urban databases by means of an automatic assessment using polygon-based methodology. Our study is based on a simulation process, which extracts pairs of homologous polygons from the assessed and reference data sources and applies two buffer-based methods. The parameter used for determining the different sizes (which range from 5 km up to 100 km has been the length of the polygons’ perimeter, and for each sample size 1000 simulations were run. After completing the simulation process, the comparisons between the estimated distribution functions for each sample and population distribution function were carried out by means of the Kolmogorov–Smirnov test. Results show a significant reduction in the variability of estimations when sample size increased from 5 km to 100 km.

  16. Sample size determination for disease prevalence studies with partially validated data.

    Science.gov (United States)

    Qiu, Shi-Fang; Poon, Wai-Yin; Tang, Man-Lai

    2016-02-01

    Disease prevalence is an important topic in medical research, and its study is based on data that are obtained by classifying subjects according to whether a disease has been contracted. Classification can be conducted with high-cost gold standard tests or low-cost screening tests, but the latter are subject to the misclassification of subjects. As a compromise between the two, many research studies use partially validated datasets in which all data points are classified by fallible tests, and some of the data points are validated in the sense that they are also classified by the completely accurate gold-standard test. In this article, we investigate the determination of sample sizes for disease prevalence studies with partially validated data. We use two approaches. The first is to find sample sizes that can achieve a pre-specified power of a statistical test at a chosen significance level, and the second is to find sample sizes that can control the width of a confidence interval with a pre-specified confidence level. Empirical studies have been conducted to demonstrate the performance of various testing procedures with the proposed sample sizes. The applicability of the proposed methods are illustrated by a real-data example. © The Author(s) 2012.

  17. Determination of cluster size of Pratylenchus Penetrans ...

    African Journals Online (AJOL)

    A nursery field 21 m x 80 m was sampled sequentially for Pratylenchus penetrans by decreasing the plot sizes systematically. Plots sizes of 3.6 m x 8 m, 3.6 m x 3.6 m and 0.6 m x 0.6 m were sampled. Nematode counts were computed to obtain the respective sample mean and variance. The sample mean and variance ...

  18. Optimal Sample Size for Probability of Detection Curves

    International Nuclear Information System (INIS)

    Annis, Charles; Gandossi, Luca; Martin, Oliver

    2012-01-01

    The use of Probability of Detection (POD) curves to quantify NDT reliability is common in the aeronautical industry, but relatively less so in the nuclear industry. The European Network for Inspection Qualification's (ENIQ) Inspection Qualification Methodology is based on the concept of Technical Justification, a document assembling all the evidence to assure that the NDT system in focus is indeed capable of finding the flaws for which it was designed. This methodology has become widely used in many countries, but the assurance it provides is usually of qualitative nature. The need to quantify the output of inspection qualification has become more important, especially as structural reliability modelling and quantitative risk-informed in-service inspection methodologies become more widely used. To credit the inspections in structural reliability evaluations, a measure of the NDT reliability is necessary. A POD curve provides such metric. In 2010 ENIQ developed a technical report on POD curves, reviewing the statistical models used to quantify inspection reliability. Further work was subsequently carried out to investigate the issue of optimal sample size for deriving a POD curve, so that adequate guidance could be given to the practitioners of inspection reliability. Manufacturing of test pieces with cracks that are representative of real defects found in nuclear power plants (NPP) can be very expensive. Thus there is a tendency to reduce sample sizes and in turn reduce the conservatism associated with the POD curve derived. Not much guidance on the correct sample size can be found in the published literature, where often qualitative statements are given with no further justification. The aim of this paper is to summarise the findings of such work. (author)

  19. On Using a Pilot Sample Variance for Sample Size Determination in the Detection of Differences between Two Means: Power Consideration

    Science.gov (United States)

    Shieh, Gwowen

    2013-01-01

    The a priori determination of a proper sample size necessary to achieve some specified power is an important problem encountered frequently in practical studies. To establish the needed sample size for a two-sample "t" test, researchers may conduct the power analysis by specifying scientifically important values as the underlying population means…

  20. Comparing Server Energy Use and Efficiency Using Small Sample Sizes

    Energy Technology Data Exchange (ETDEWEB)

    Coles, Henry C.; Qin, Yong; Price, Phillip N.

    2014-11-01

    This report documents a demonstration that compared the energy consumption and efficiency of a limited sample size of server-type IT equipment from different manufacturers by measuring power at the server power supply power cords. The results are specific to the equipment and methods used. However, it is hoped that those responsible for IT equipment selection can used the methods described to choose models that optimize energy use efficiency. The demonstration was conducted in a data center at Lawrence Berkeley National Laboratory in Berkeley, California. It was performed with five servers of similar mechanical and electronic specifications; three from Intel and one each from Dell and Supermicro. Server IT equipment is constructed using commodity components, server manufacturer-designed assemblies, and control systems. Server compute efficiency is constrained by the commodity component specifications and integration requirements. The design freedom, outside of the commodity component constraints, provides room for the manufacturer to offer a product with competitive efficiency that meets market needs at a compelling price. A goal of the demonstration was to compare and quantify the server efficiency for three different brands. The efficiency is defined as the average compute rate (computations per unit of time) divided by the average energy consumption rate. The research team used an industry standard benchmark software package to provide a repeatable software load to obtain the compute rate and provide a variety of power consumption levels. Energy use when the servers were in an idle state (not providing computing work) were also measured. At high server compute loads, all brands, using the same key components (processors and memory), had similar results; therefore, from these results, it could not be concluded that one brand is more efficient than the other brands. The test results show that the power consumption variability caused by the key components as a

  1. What is the optimum sample size for the study of peatland testate amoeba assemblages?

    Science.gov (United States)

    Mazei, Yuri A; Tsyganov, Andrey N; Esaulov, Anton S; Tychkov, Alexander Yu; Payne, Richard J

    2017-10-01

    Testate amoebae are widely used in ecological and palaeoecological studies of peatlands, particularly as indicators of surface wetness. To ensure data are robust and comparable it is important to consider methodological factors which may affect results. One significant question which has not been directly addressed in previous studies is how sample size (expressed here as number of Sphagnum stems) affects data quality. In three contrasting locations in a Russian peatland we extracted samples of differing size, analysed testate amoebae and calculated a number of widely-used indices: species richness, Simpson diversity, compositional dissimilarity from the largest sample and transfer function predictions of water table depth. We found that there was a trend for larger samples to contain more species across the range of commonly-used sample sizes in ecological studies. Smaller samples sometimes failed to produce counts of testate amoebae often considered minimally adequate. It seems likely that analyses based on samples of different sizes may not produce consistent data. Decisions about sample size need to reflect trade-offs between logistics, data quality, spatial resolution and the disturbance involved in sample extraction. For most common ecological applications we suggest that samples of more than eight Sphagnum stems are likely to be desirable. Copyright © 2017 Elsevier GmbH. All rights reserved.

  2. [Sample size calculation in clinical post-marketing evaluation of traditional Chinese medicine].

    Science.gov (United States)

    Fu, Yingkun; Xie, Yanming

    2011-10-01

    In recent years, as the Chinese government and people pay more attention on the post-marketing research of Chinese Medicine, part of traditional Chinese medicine breed has or is about to begin after the listing of post-marketing evaluation study. In the post-marketing evaluation design, sample size calculation plays a decisive role. It not only ensures the accuracy and reliability of post-marketing evaluation. but also assures that the intended trials will have a desired power for correctly detecting a clinically meaningful difference of different medicine under study if such a difference truly exists. Up to now, there is no systemic method of sample size calculation in view of the traditional Chinese medicine. In this paper, according to the basic method of sample size calculation and the characteristic of the traditional Chinese medicine clinical evaluation, the sample size calculation methods of the Chinese medicine efficacy and safety are discussed respectively. We hope the paper would be beneficial to medical researchers, and pharmaceutical scientists who are engaged in the areas of Chinese medicine research.

  3. Effects of sample size on estimates of population growth rates calculated with matrix models.

    Directory of Open Access Journals (Sweden)

    Ian J Fiske

    Full Text Available BACKGROUND: Matrix models are widely used to study the dynamics and demography of populations. An important but overlooked issue is how the number of individuals sampled influences estimates of the population growth rate (lambda calculated with matrix models. Even unbiased estimates of vital rates do not ensure unbiased estimates of lambda-Jensen's Inequality implies that even when the estimates of the vital rates are accurate, small sample sizes lead to biased estimates of lambda due to increased sampling variance. We investigated if sampling variability and the distribution of sampling effort among size classes lead to biases in estimates of lambda. METHODOLOGY/PRINCIPAL FINDINGS: Using data from a long-term field study of plant demography, we simulated the effects of sampling variance by drawing vital rates and calculating lambda for increasingly larger populations drawn from a total population of 3842 plants. We then compared these estimates of lambda with those based on the entire population and calculated the resulting bias. Finally, we conducted a review of the literature to determine the sample sizes typically used when parameterizing matrix models used to study plant demography. CONCLUSIONS/SIGNIFICANCE: We found significant bias at small sample sizes when survival was low (survival = 0.5, and that sampling with a more-realistic inverse J-shaped population structure exacerbated this bias. However our simulations also demonstrate that these biases rapidly become negligible with increasing sample sizes or as survival increases. For many of the sample sizes used in demographic studies, matrix models are probably robust to the biases resulting from sampling variance of vital rates. However, this conclusion may depend on the structure of populations or the distribution of sampling effort in ways that are unexplored. We suggest more intensive sampling of populations when individual survival is low and greater sampling of stages with high

  4. Effects of sample size on estimates of population growth rates calculated with matrix models.

    Science.gov (United States)

    Fiske, Ian J; Bruna, Emilio M; Bolker, Benjamin M

    2008-08-28

    Matrix models are widely used to study the dynamics and demography of populations. An important but overlooked issue is how the number of individuals sampled influences estimates of the population growth rate (lambda) calculated with matrix models. Even unbiased estimates of vital rates do not ensure unbiased estimates of lambda-Jensen's Inequality implies that even when the estimates of the vital rates are accurate, small sample sizes lead to biased estimates of lambda due to increased sampling variance. We investigated if sampling variability and the distribution of sampling effort among size classes lead to biases in estimates of lambda. Using data from a long-term field study of plant demography, we simulated the effects of sampling variance by drawing vital rates and calculating lambda for increasingly larger populations drawn from a total population of 3842 plants. We then compared these estimates of lambda with those based on the entire population and calculated the resulting bias. Finally, we conducted a review of the literature to determine the sample sizes typically used when parameterizing matrix models used to study plant demography. We found significant bias at small sample sizes when survival was low (survival = 0.5), and that sampling with a more-realistic inverse J-shaped population structure exacerbated this bias. However our simulations also demonstrate that these biases rapidly become negligible with increasing sample sizes or as survival increases. For many of the sample sizes used in demographic studies, matrix models are probably robust to the biases resulting from sampling variance of vital rates. However, this conclusion may depend on the structure of populations or the distribution of sampling effort in ways that are unexplored. We suggest more intensive sampling of populations when individual survival is low and greater sampling of stages with high elasticities.

  5. Computing physical properties with quantum Monte Carlo methods with statistical fluctuations independent of system size.

    Science.gov (United States)

    Assaraf, Roland

    2014-12-01

    We show that the recently proposed correlated sampling without reweighting procedure extends the locality (asymptotic independence of the system size) of a physical property to the statistical fluctuations of its estimator. This makes the approach potentially vastly more efficient for computing space-localized properties in large systems compared with standard correlated methods. A proof is given for a large collection of noninteracting fragments. Calculations on hydrogen chains suggest that this behavior holds not only for systems displaying short-range correlations, but also for systems with long-range correlations.

  6. Influence of pore size distributions on decomposition of maize leaf residue: evidence from X-ray computed micro-tomography

    Science.gov (United States)

    Negassa, Wakene; Guber, Andrey; Kravchenko, Alexandra; Rivers, Mark

    2014-05-01

    Soil's potential to sequester carbon (C) depends not only on quality and quantity of organic inputs to soil but also on the residence time of the applied organic inputs within the soil. Soil pore structure is one of the main factors that influence residence time of soil organic matter by controlling gas exchange, soil moisture and microbial activities, thereby soil C sequestration capacity. Previous attempts to investigate the fate of organic inputs added to soil did not allow examining their decomposition in situ; the drawback that can now be remediated by application of X-ray computed micro-tomography (µ-CT). The non-destructive and non-invasive nature of µ-CT gives an opportunity to investigate the effect of soil pore size distributions on decomposition of plant residues at a new quantitative level. The objective of this study is to examine the influence of pore size distributions on the decomposition of plant residue added to soil. Samples with contrasting pore size distributions were created using aggregate fractions of five different sizes (pieces of maize leaves 2.5 mg in size (equivalent to 1.71 mg C g-1 soil) were added to half of the studied samples. Samples with and without maize leaves were incubated for 120 days. CO2 emission from the samples was measured at regular time intervals. In order to ensure that the observed differences are due to differences in pore structure and not due to differences in inherent properties of the studied aggregate fractions, we repeated the whole experiment using soil from the same aggregate size fractions but ground to six replicated samples were used for intact and ground samples of all sizes with and without leaves. Two replications of the intact aggregate fractions of all sizes with leaves were subjected to µ-CT scanning before and after incubation, whereas all the remaining replications of both intact and ground aggregate fractions of <0.05, 0.05-0.1, and 1.0-2.0 mm sizes with leaves were scanned with µ-CT after

  7. Determining sample size for assessing species composition in ...

    African Journals Online (AJOL)

    Species composition is measured in grasslands for a variety of reasons. Commonly, observations are made using the wheel-point apparatus, but the problem of determining optimum sample size has not yet been satisfactorily resolved. In this study the wheel-point apparatus was used to record 2 000 observations in each of ...

  8. Sample size adjustments for varying cluster sizes in cluster randomized trials with binary outcomes analyzed with second-order PQL mixed logistic regression.

    Science.gov (United States)

    Candel, Math J J M; Van Breukelen, Gerard J P

    2010-06-30

    Adjustments of sample size formulas are given for varying cluster sizes in cluster randomized trials with a binary outcome when testing the treatment effect with mixed effects logistic regression using second-order penalized quasi-likelihood estimation (PQL). Starting from first-order marginal quasi-likelihood (MQL) estimation of the treatment effect, the asymptotic relative efficiency of unequal versus equal cluster sizes is derived. A Monte Carlo simulation study shows this asymptotic relative efficiency to be rather accurate for realistic sample sizes, when employing second-order PQL. An approximate, simpler formula is presented to estimate the efficiency loss due to varying cluster sizes when planning a trial. In many cases sampling 14 per cent more clusters is sufficient to repair the efficiency loss due to varying cluster sizes. Since current closed-form formulas for sample size calculation are based on first-order MQL, planning a trial also requires a conversion factor to obtain the variance of the second-order PQL estimator. In a second Monte Carlo study, this conversion factor turned out to be 1.25 at most. (c) 2010 John Wiley & Sons, Ltd.

  9. The effect of clustering on lot quality assurance sampling: a probabilistic model to calculate sample sizes for quality assessments.

    Science.gov (United States)

    Hedt-Gauthier, Bethany L; Mitsunaga, Tisha; Hund, Lauren; Olives, Casey; Pagano, Marcello

    2013-10-26

    Traditional Lot Quality Assurance Sampling (LQAS) designs assume observations are collected using simple random sampling. Alternatively, randomly sampling clusters of observations and then individuals within clusters reduces costs but decreases the precision of the classifications. In this paper, we develop a general framework for designing the cluster(C)-LQAS system and illustrate the method with the design of data quality assessments for the community health worker program in Rwanda. To determine sample size and decision rules for C-LQAS, we use the beta-binomial distribution to account for inflated risk of errors introduced by sampling clusters at the first stage. We present general theory and code for sample size calculations.The C-LQAS sample sizes provided in this paper constrain misclassification risks below user-specified limits. Multiple C-LQAS systems meet the specified risk requirements, but numerous considerations, including per-cluster versus per-individual sampling costs, help identify optimal systems for distinct applications. We show the utility of C-LQAS for data quality assessments, but the method generalizes to numerous applications. This paper provides the necessary technical detail and supplemental code to support the design of C-LQAS for specific programs.

  10. The impact of sample size on the reproducibility of voxel-based lesion-deficit mappings.

    Science.gov (United States)

    Lorca-Puls, Diego L; Gajardo-Vidal, Andrea; White, Jitrachote; Seghier, Mohamed L; Leff, Alexander P; Green, David W; Crinion, Jenny T; Ludersdorfer, Philipp; Hope, Thomas M H; Bowman, Howard; Price, Cathy J

    2018-07-01

    This study investigated how sample size affects the reproducibility of findings from univariate voxel-based lesion-deficit analyses (e.g., voxel-based lesion-symptom mapping and voxel-based morphometry). Our effect of interest was the strength of the mapping between brain damage and speech articulation difficulties, as measured in terms of the proportion of variance explained. First, we identified a region of interest by searching on a voxel-by-voxel basis for brain areas where greater lesion load was associated with poorer speech articulation using a large sample of 360 right-handed English-speaking stroke survivors. We then randomly drew thousands of bootstrap samples from this data set that included either 30, 60, 90, 120, 180, or 360 patients. For each resample, we recorded effect size estimates and p values after conducting exactly the same lesion-deficit analysis within the previously identified region of interest and holding all procedures constant. The results show (1) how often small effect sizes in a heterogeneous population fail to be detected; (2) how effect size and its statistical significance varies with sample size; (3) how low-powered studies (due to small sample sizes) can greatly over-estimate as well as under-estimate effect sizes; and (4) how large sample sizes (N ≥ 90) can yield highly significant p values even when effect sizes are so small that they become trivial in practical terms. The implications of these findings for interpreting the results from univariate voxel-based lesion-deficit analyses are discussed. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  11. Micro-computed tomography characterization of tissue engineering scaffolds: effects of pixel size and rotation step.

    Science.gov (United States)

    Cengiz, Ibrahim Fatih; Oliveira, Joaquim Miguel; Reis, Rui L

    2017-08-01

    Quantitative assessment of micro-structure of materials is of key importance in many fields including tissue engineering, biology, and dentistry. Micro-computed tomography (µ-CT) is an intensively used non-destructive technique. However, the acquisition parameters such as pixel size and rotation step may have significant effects on the obtained results. In this study, a set of tissue engineering scaffolds including examples of natural and synthetic polymers, and ceramics were analyzed. We comprehensively compared the quantitative results of µ-CT characterization using 15 acquisition scenarios that differ in the combination of the pixel size and rotation step. The results showed that the acquisition parameters could statistically significantly affect the quantified mean porosity, mean pore size, and mean wall thickness of the scaffolds. The effects are also practically important since the differences can be as high as 24% regarding the mean porosity in average, and 19.5 h and 166 GB regarding the characterization time and data storage per sample with a relatively small volume. This study showed in a quantitative manner the effects of such a wide range of acquisition scenarios on the final data, as well as the characterization time and data storage per sample. Herein, a clear picture of the effects of the pixel size and rotation step on the results is provided which can notably be useful to refine the practice of µ-CT characterization of scaffolds and economize the related resources.

  12. Does increasing the size of bi-weekly samples of records influence results when using the Global Trigger Tool? An observational study of retrospective record reviews of two different sample sizes.

    Science.gov (United States)

    Mevik, Kjersti; Griffin, Frances A; Hansen, Tonje E; Deilkås, Ellen T; Vonen, Barthold

    2016-04-25

    To investigate the impact of increasing sample of records reviewed bi-weekly with the Global Trigger Tool method to identify adverse events in hospitalised patients. Retrospective observational study. A Norwegian 524-bed general hospital trust. 1920 medical records selected from 1 January to 31 December 2010. Rate, type and severity of adverse events identified in two different samples sizes of records selected as 10 and 70 records, bi-weekly. In the large sample, 1.45 (95% CI 1.07 to 1.97) times more adverse events per 1000 patient days (39.3 adverse events/1000 patient days) were identified than in the small sample (27.2 adverse events/1000 patient days). Hospital-acquired infections were the most common category of adverse events in both the samples, and the distributions of the other categories of adverse events did not differ significantly between the samples. The distribution of severity level of adverse events did not differ between the samples. The findings suggest that while the distribution of categories and severity are not dependent on the sample size, the rate of adverse events is. Further studies are needed to conclude if the optimal sample size may need to be adjusted based on the hospital size in order to detect a more accurate rate of adverse events. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Predictors of Citation Rate in Psychology: Inconclusive Influence of Effect and Sample Size.

    Science.gov (United States)

    Hanel, Paul H P; Haase, Jennifer

    2017-01-01

    In the present article, we investigate predictors of how often a scientific article is cited. Specifically, we focus on the influence of two often neglected predictors of citation rate: effect size and sample size, using samples from two psychological topical areas. Both can be considered as indicators of the importance of an article and post hoc (or observed) statistical power, and should, especially in applied fields, predict citation rates. In Study 1, effect size did not have an influence on citation rates across a topical area, both with and without controlling for numerous variables that have been previously linked to citation rates. In contrast, sample size predicted citation rates, but only while controlling for other variables. In Study 2, sample and partly effect sizes predicted citation rates, indicating that the relations vary even between scientific topical areas. Statistically significant results had more citations in Study 2 but not in Study 1. The results indicate that the importance (or power) of scientific findings may not be as strongly related to citation rate as is generally assumed.

  14. Sample size calculation to externally validate scoring systems based on logistic regression models.

    Directory of Open Access Journals (Sweden)

    Antonio Palazón-Bru

    Full Text Available A sample size containing at least 100 events and 100 non-events has been suggested to validate a predictive model, regardless of the model being validated and that certain factors can influence calibration of the predictive model (discrimination, parameterization and incidence. Scoring systems based on binary logistic regression models are a specific type of predictive model.The aim of this study was to develop an algorithm to determine the sample size for validating a scoring system based on a binary logistic regression model and to apply it to a case study.The algorithm was based on bootstrap samples in which the area under the ROC curve, the observed event probabilities through smooth curves, and a measure to determine the lack of calibration (estimated calibration index were calculated. To illustrate its use for interested researchers, the algorithm was applied to a scoring system, based on a binary logistic regression model, to determine mortality in intensive care units.In the case study provided, the algorithm obtained a sample size with 69 events, which is lower than the value suggested in the literature.An algorithm is provided for finding the appropriate sample size to validate scoring systems based on binary logistic regression models. This could be applied to determine the sample size in other similar cases.

  15. Estimated ventricle size using Evans index: reference values from a population-based sample.

    Science.gov (United States)

    Jaraj, D; Rabiei, K; Marlow, T; Jensen, C; Skoog, I; Wikkelsø, C

    2017-03-01

    Evans index is an estimate of ventricular size used in the diagnosis of idiopathic normal-pressure hydrocephalus (iNPH). Values >0.3 are considered pathological and are required by guidelines for the diagnosis of iNPH. However, there are no previous epidemiological studies on Evans index, and normal values in adults are thus not precisely known. We examined a representative sample to obtain reference values and descriptive data on Evans index. A population-based sample (n = 1235) of men and women aged ≥70 years was examined. The sample comprised people living in private households and residential care, systematically selected from the Swedish population register. Neuropsychiatric examinations, including head computed tomography, were performed between 1986 and 2000. Evans index ranged from 0.11 to 0.46. The mean value in the total sample was 0.28 (SD, 0.04) and 20.6% (n = 255) had values >0.3. Among men aged ≥80 years, the mean value of Evans index was 0.3 (SD, 0.03). Individuals with dementia had a mean value of Evans index of 0.31 (SD, 0.05) and those with radiological signs of iNPH had a mean value of 0.36 (SD, 0.04). A substantial number of subjects had ventricular enlargement according to current criteria. Clinicians and researchers need to be aware of the range of values among older individuals. © 2017 EAN.

  16. Size selective isocyanate aerosols personal air sampling using porous plastic foams

    International Nuclear Information System (INIS)

    Cong Khanh Huynh; Trinh Vu Duc

    2009-01-01

    As part of a European project (SMT4-CT96-2137), various European institutions specialized in occupational hygiene (BGIA, HSL, IOM, INRS, IST, Ambiente e Lavoro) have established a program of scientific collaboration to develop one or more prototypes of European personal samplers for the collection of simultaneous three dust fractions: inhalable, thoracic and respirable. These samplers based on existing sampling heads (IOM, GSP and cassettes) use Polyurethane Plastic Foam (PUF) according to their porosity to support sampling and separator size of the particles. In this study, the authors present an original application of size selective personal air sampling using chemical impregnated PUF to perform isocyanate aerosols capturing and derivatizing in industrial spray-painting shops.

  17. An integrated approach for multi-level sample size determination

    International Nuclear Information System (INIS)

    Lu, M.S.; Teichmann, T.; Sanborn, J.B.

    1997-01-01

    Inspection procedures involving the sampling of items in a population often require steps of increasingly sensitive measurements, with correspondingly smaller sample sizes; these are referred to as multilevel sampling schemes. In the case of nuclear safeguards inspections verifying that there has been no diversion of Special Nuclear Material (SNM), these procedures have been examined often and increasingly complex algorithms have been developed to implement them. The aim in this paper is to provide an integrated approach, and, in so doing, to describe a systematic, consistent method that proceeds logically from level to level with increasing accuracy. The authors emphasize that the methods discussed are generally consistent with those presented in the references mentioned, and yield comparable results when the error models are the same. However, because of its systematic, integrated approach the proposed method elucidates the conceptual understanding of what goes on, and, in many cases, simplifies the calculations. In nuclear safeguards inspections, an important aspect of verifying nuclear items to detect any possible diversion of nuclear fissile materials is the sampling of such items at various levels of sensitivity. The first step usually is sampling by ''attributes'' involving measurements of relatively low accuracy, followed by further levels of sampling involving greater accuracy. This process is discussed in some detail in the references given; also, the nomenclature is described. Here, the authors outline a coordinated step-by-step procedure for achieving such multilevel sampling, and they develop the relationships between the accuracy of measurement and the sample size required at each stage, i.e., at the various levels. The logic of the underlying procedures is carefully elucidated; the calculations involved and their implications, are clearly described, and the process is put in a form that allows systematic generalization

  18. Quantum supremacy in constant-time measurement-based computation: A unified architecture for sampling and verification

    Science.gov (United States)

    Miller, Jacob; Sanders, Stephen; Miyake, Akimasa

    2017-12-01

    While quantum speed-up in solving certain decision problems by a fault-tolerant universal quantum computer has been promised, a timely research interest includes how far one can reduce the resource requirement to demonstrate a provable advantage in quantum devices without demanding quantum error correction, which is crucial for prolonging the coherence time of qubits. We propose a model device made of locally interacting multiple qubits, designed such that simultaneous single-qubit measurements on it can output probability distributions whose average-case sampling is classically intractable, under similar assumptions as the sampling of noninteracting bosons and instantaneous quantum circuits. Notably, in contrast to these previous unitary-based realizations, our measurement-based implementation has two distinctive features. (i) Our implementation involves no adaptation of measurement bases, leading output probability distributions to be generated in constant time, independent of the system size. Thus, it could be implemented in principle without quantum error correction. (ii) Verifying the classical intractability of our sampling is done by changing the Pauli measurement bases only at certain output qubits. Our usage of random commuting quantum circuits in place of computationally universal circuits allows a unique unification of sampling and verification, so they require the same physical resource requirements in contrast to the more demanding verification protocols seen elsewhere in the literature.

  19. Computational scalability of large size image dissemination

    Science.gov (United States)

    Kooper, Rob; Bajcsy, Peter

    2011-01-01

    We have investigated the computational scalability of image pyramid building needed for dissemination of very large image data. The sources of large images include high resolution microscopes and telescopes, remote sensing and airborne imaging, and high resolution scanners. The term 'large' is understood from a user perspective which means either larger than a display size or larger than a memory/disk to hold the image data. The application drivers for our work are digitization projects such as the Lincoln Papers project (each image scan is about 100-150MB or about 5000x8000 pixels with the total number to be around 200,000) and the UIUC library scanning project for historical maps from 17th and 18th century (smaller number but larger images). The goal of our work is understand computational scalability of the web-based dissemination using image pyramids for these large image scans, as well as the preservation aspects of the data. We report our computational benchmarks for (a) building image pyramids to be disseminated using the Microsoft Seadragon library, (b) a computation execution approach using hyper-threading to generate image pyramids and to utilize the underlying hardware, and (c) an image pyramid preservation approach using various hard drive configurations of Redundant Array of Independent Disks (RAID) drives for input/output operations. The benchmarks are obtained with a map (334.61 MB, JPEG format, 17591x15014 pixels). The discussion combines the speed and preservation objectives.

  20. Estimation of sample size and testing power (Part 3).

    Science.gov (United States)

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2011-12-01

    This article introduces the definition and sample size estimation of three special tests (namely, non-inferiority test, equivalence test and superiority test) for qualitative data with the design of one factor with two levels having a binary response variable. Non-inferiority test refers to the research design of which the objective is to verify that the efficacy of the experimental drug is not clinically inferior to that of the positive control drug. Equivalence test refers to the research design of which the objective is to verify that the experimental drug and the control drug have clinically equivalent efficacy. Superiority test refers to the research design of which the objective is to verify that the efficacy of the experimental drug is clinically superior to that of the control drug. By specific examples, this article introduces formulas of sample size estimation for the three special tests, and their SAS realization in detail.

  1. Overcoming time scale and finite size limitations to compute nucleation rates from small scale well tempered metadynamics simulations

    Science.gov (United States)

    Salvalaglio, Matteo; Tiwary, Pratyush; Maggioni, Giovanni Maria; Mazzotti, Marco; Parrinello, Michele

    2016-12-01

    Condensation of a liquid droplet from a supersaturated vapour phase is initiated by a prototypical nucleation event. As such it is challenging to compute its rate from atomistic molecular dynamics simulations. In fact at realistic supersaturation conditions condensation occurs on time scales that far exceed what can be reached with conventional molecular dynamics methods. Another known problem in this context is the distortion of the free energy profile associated to nucleation due to the small, finite size of typical simulation boxes. In this work the problem of time scale is addressed with a recently developed enhanced sampling method while contextually correcting for finite size effects. We demonstrate our approach by studying the condensation of argon, and showing that characteristic nucleation times of the order of magnitude of hours can be reliably calculated. Nucleation rates spanning a range of 10 orders of magnitude are computed at moderate supersaturation levels, thus bridging the gap between what standard molecular dynamics simulations can do and real physical systems.

  2. Species richness in soil bacterial communities: a proposed approach to overcome sample size bias.

    Science.gov (United States)

    Youssef, Noha H; Elshahed, Mostafa S

    2008-09-01

    Estimates of species richness based on 16S rRNA gene clone libraries are increasingly utilized to gauge the level of bacterial diversity within various ecosystems. However, previous studies have indicated that regardless of the utilized approach, species richness estimates obtained are dependent on the size of the analyzed clone libraries. We here propose an approach to overcome sample size bias in species richness estimates in complex microbial communities. Parametric (Maximum likelihood-based and rarefaction curve-based) and non-parametric approaches were used to estimate species richness in a library of 13,001 near full-length 16S rRNA clones derived from soil, as well as in multiple subsets of the original library. Species richness estimates obtained increased with the increase in library size. To obtain a sample size-unbiased estimate of species richness, we calculated the theoretical clone library sizes required to encounter the estimated species richness at various clone library sizes, used curve fitting to determine the theoretical clone library size required to encounter the "true" species richness, and subsequently determined the corresponding sample size-unbiased species richness value. Using this approach, sample size-unbiased estimates of 17,230, 15,571, and 33,912 were obtained for the ML-based, rarefaction curve-based, and ACE-1 estimators, respectively, compared to bias-uncorrected values of 15,009, 11,913, and 20,909.

  3. [Formal sample size calculation and its limited validity in animal studies of medical basic research].

    Science.gov (United States)

    Mayer, B; Muche, R

    2013-01-01

    Animal studies are highly relevant for basic medical research, although their usage is discussed controversially in public. Thus, an optimal sample size for these projects should be aimed at from a biometrical point of view. Statistical sample size calculation is usually the appropriate methodology in planning medical research projects. However, required information is often not valid or only available during the course of an animal experiment. This article critically discusses the validity of formal sample size calculation for animal studies. Within the discussion, some requirements are formulated to fundamentally regulate the process of sample size determination for animal experiments.

  4. Improved Patient Size Estimates for Accurate Dose Calculations in Abdomen Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang-Lae [Yonsei University, Wonju (Korea, Republic of)

    2017-07-15

    The radiation dose of CT (computed tomography) is generally represented by the CTDI (CT dose index). CTDI, however, does not accurately predict the actual patient doses for different human body sizes because it relies on a cylinder-shaped head (diameter : 16 cm) and body (diameter : 32 cm) phantom. The purpose of this study was to eliminate the drawbacks of the conventional CTDI and to provide more accurate radiation dose information. Projection radiographs were obtained from water cylinder phantoms of various sizes, and the sizes of the water cylinder phantoms were calculated and verified using attenuation profiles. The effective diameter was also calculated using the attenuation of the abdominal projection radiographs of 10 patients. When the results of the attenuation-based method and the geometry-based method shown were compared with the results of the reconstructed-axial-CT-image-based method, the effective diameter of the attenuation-based method was found to be similar to the effective diameter of the reconstructed-axial-CT-image-based method, with a difference of less than 3.8%, but the geometry-based method showed a difference of less than 11.4%. This paper proposes a new method of accurately computing the radiation dose of CT based on the patient sizes. This method computes and provides the exact patient dose before the CT scan, and can therefore be effectively used for imaging and dose control.

  5. Generating Random Samples of a Given Size Using Social Security Numbers.

    Science.gov (United States)

    Erickson, Richard C.; Brauchle, Paul E.

    1984-01-01

    The purposes of this article are (1) to present a method by which social security numbers may be used to draw cluster samples of a predetermined size and (2) to describe procedures used to validate this method of drawing random samples. (JOW)

  6. Effect of micro-computed tomography voxel size and segmentation method on trabecular bone microstructure measures in mice

    Directory of Open Access Journals (Sweden)

    Blaine A. Christiansen

    2016-12-01

    Full Text Available Micro-computed tomography (μCT is currently the gold standard for determining trabecular bone microstructure in small animal models. Numerous parameters associated with scanning and evaluation of μCT scans can strongly affect morphologic results obtained from bone samples. However, the effect of these parameters on specific trabecular bone outcomes is not well understood. This study investigated the effect of μCT scanning with nominal voxel sizes between 6–30 μm on trabecular bone outcomes quantified in mouse vertebral body trabecular bone. Additionally, two methods for determining a global segmentation threshold were compared: based on qualitative assessment of 2D images, or based on quantitative assessment of image histograms. It was found that nominal voxel size had a strong effect on several commonly reported trabecular bone parameters, in particular connectivity density, trabecular thickness, and bone tissue mineral density. Additionally, the two segmentation methods provided similar trabecular bone outcomes for scans with small nominal voxel sizes, but considerably different outcomes for scans with larger voxel sizes. The Qualitatively Selected segmentation method more consistently estimated trabecular bone volume fraction (BV/TV and trabecular thickness across different voxel sizes, but the Histogram segmentation method more consistently estimated trabecular number, trabecular separation, and structure model index. Altogether, these results suggest that high-resolution scans be used whenever possible to provide the most accurate estimation of trabecular bone microstructure, and that the limitations of accurately determining trabecular bone outcomes should be considered when selecting scan parameters and making conclusions about inter-group variance or between-group differences in studies of trabecular bone microstructure in small animals. Keywords: Trabecular bone, Microstructure, Micro-computed tomography, Voxel size, Resolution

  7. On sample size and different interpretations of snow stability datasets

    Science.gov (United States)

    Schirmer, M.; Mitterer, C.; Schweizer, J.

    2009-04-01

    Interpretations of snow stability variations need an assessment of the stability itself, independent of the scale investigated in the study. Studies on stability variations at a regional scale have often chosen stability tests such as the Rutschblock test or combinations of various tests in order to detect differences in aspect and elevation. The question arose: ‘how capable are such stability interpretations in drawing conclusions'. There are at least three possible errors sources: (i) the variance of the stability test itself; (ii) the stability variance at an underlying slope scale, and (iii) that the stability interpretation might not be directly related to the probability of skier triggering. Various stability interpretations have been proposed in the past that provide partly different results. We compared a subjective one based on expert knowledge with a more objective one based on a measure derived from comparing skier-triggered slopes vs. slopes that have been skied but not triggered. In this study, the uncertainties are discussed and their effects on regional scale stability variations will be quantified in a pragmatic way. An existing dataset with very large sample sizes was revisited. This dataset contained the variance of stability at a regional scale for several situations. The stability in this dataset was determined using the subjective interpretation scheme based on expert knowledge. The question to be answered was how many measurements were needed to obtain similar results (mainly stability differences in aspect or elevation) as with the complete dataset. The optimal sample size was obtained in several ways: (i) assuming a nominal data scale the sample size was determined with a given test, significance level and power, and by calculating the mean and standard deviation of the complete dataset. With this method it can also be determined if the complete dataset consists of an appropriate sample size. (ii) Smaller subsets were created with similar

  8. Support vector regression to predict porosity and permeability: Effect of sample size

    Science.gov (United States)

    Al-Anazi, A. F.; Gates, I. D.

    2012-02-01

    Porosity and permeability are key petrophysical parameters obtained from laboratory core analysis. Cores, obtained from drilled wells, are often few in number for most oil and gas fields. Porosity and permeability correlations based on conventional techniques such as linear regression or neural networks trained with core and geophysical logs suffer poor generalization to wells with only geophysical logs. The generalization problem of correlation models often becomes pronounced when the training sample size is small. This is attributed to the underlying assumption that conventional techniques employing the empirical risk minimization (ERM) inductive principle converge asymptotically to the true risk values as the number of samples increases. In small sample size estimation problems, the available training samples must span the complexity of the parameter space so that the model is able both to match the available training samples reasonably well and to generalize to new data. This is achieved using the structural risk minimization (SRM) inductive principle by matching the capability of the model to the available training data. One method that uses SRM is support vector regression (SVR) network. In this research, the capability of SVR to predict porosity and permeability in a heterogeneous sandstone reservoir under the effect of small sample size is evaluated. Particularly, the impact of Vapnik's ɛ-insensitivity loss function and least-modulus loss function on generalization performance was empirically investigated. The results are compared to the multilayer perception (MLP) neural network, a widely used regression method, which operates under the ERM principle. The mean square error and correlation coefficients were used to measure the quality of predictions. The results demonstrate that SVR yields consistently better predictions of the porosity and permeability with small sample size than the MLP method. Also, the performance of SVR depends on both kernel function

  9. The PowerAtlas: a power and sample size atlas for microarray experimental design and research

    Directory of Open Access Journals (Sweden)

    Wang Jelai

    2006-02-01

    Full Text Available Abstract Background Microarrays permit biologists to simultaneously measure the mRNA abundance of thousands of genes. An important issue facing investigators planning microarray experiments is how to estimate the sample size required for good statistical power. What is the projected sample size or number of replicate chips needed to address the multiple hypotheses with acceptable accuracy? Statistical methods exist for calculating power based upon a single hypothesis, using estimates of the variability in data from pilot studies. There is, however, a need for methods to estimate power and/or required sample sizes in situations where multiple hypotheses are being tested, such as in microarray experiments. In addition, investigators frequently do not have pilot data to estimate the sample sizes required for microarray studies. Results To address this challenge, we have developed a Microrarray PowerAtlas 1. The atlas enables estimation of statistical power by allowing investigators to appropriately plan studies by building upon previous studies that have similar experimental characteristics. Currently, there are sample sizes and power estimates based on 632 experiments from Gene Expression Omnibus (GEO. The PowerAtlas also permits investigators to upload their own pilot data and derive power and sample size estimates from these data. This resource will be updated regularly with new datasets from GEO and other databases such as The Nottingham Arabidopsis Stock Center (NASC. Conclusion This resource provides a valuable tool for investigators who are planning efficient microarray studies and estimating required sample sizes.

  10. The quality of the reported sample size calculations in randomized controlled trials indexed in PubMed.

    Science.gov (United States)

    Lee, Paul H; Tse, Andy C Y

    2017-05-01

    There are limited data on the quality of reporting of information essential for replication of the calculation as well as the accuracy of the sample size calculation. We examine the current quality of reporting of the sample size calculation in randomized controlled trials (RCTs) published in PubMed and to examine the variation in reporting across study design, study characteristics, and journal impact factor. We also reviewed the targeted sample size reported in trial registries. We reviewed and analyzed all RCTs published in December 2014 with journals indexed in PubMed. The 2014 Impact Factors for the journals were used as proxies for their quality. Of the 451 analyzed papers, 58.1% reported an a priori sample size calculation. Nearly all papers provided the level of significance (97.7%) and desired power (96.6%), and most of the papers reported the minimum clinically important effect size (73.3%). The median (inter-quartile range) of the percentage difference of the reported and calculated sample size calculation was 0.0% (IQR -4.6%;3.0%). The accuracy of the reported sample size was better for studies published in journals that endorsed the CONSORT statement and journals with an impact factor. A total of 98 papers had provided targeted sample size on trial registries and about two-third of these papers (n=62) reported sample size calculation, but only 25 (40.3%) had no discrepancy with the reported number in the trial registries. The reporting of the sample size calculation in RCTs published in PubMed-indexed journals and trial registries were poor. The CONSORT statement should be more widely endorsed. Copyright © 2016 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.

  11. A hybrid computational strategy to address WGS variant analysis in >5000 samples.

    Science.gov (United States)

    Huang, Zhuoyi; Rustagi, Navin; Veeraraghavan, Narayanan; Carroll, Andrew; Gibbs, Richard; Boerwinkle, Eric; Venkata, Manjunath Gorentla; Yu, Fuli

    2016-09-10

    The decreasing costs of sequencing are driving the need for cost effective and real time variant calling of whole genome sequencing data. The scale of these projects are far beyond the capacity of typical computing resources available with most research labs. Other infrastructures like the cloud AWS environment and supercomputers also have limitations due to which large scale joint variant calling becomes infeasible, and infrastructure specific variant calling strategies either fail to scale up to large datasets or abandon joint calling strategies. We present a high throughput framework including multiple variant callers for single nucleotide variant (SNV) calling, which leverages hybrid computing infrastructure consisting of cloud AWS, supercomputers and local high performance computing infrastructures. We present a novel binning approach for large scale joint variant calling and imputation which can scale up to over 10,000 samples while producing SNV callsets with high sensitivity and specificity. As a proof of principle, we present results of analysis on Cohorts for Heart And Aging Research in Genomic Epidemiology (CHARGE) WGS freeze 3 dataset in which joint calling, imputation and phasing of over 5300 whole genome samples was produced in under 6 weeks using four state-of-the-art callers. The callers used were SNPTools, GATK-HaplotypeCaller, GATK-UnifiedGenotyper and GotCloud. We used Amazon AWS, a 4000-core in-house cluster at Baylor College of Medicine, IBM power PC Blue BioU at Rice and Rhea at Oak Ridge National Laboratory (ORNL) for the computation. AWS was used for joint calling of 180 TB of BAM files, and ORNL and Rice supercomputers were used for the imputation and phasing step. All other steps were carried out on the local compute cluster. The entire operation used 5.2 million core hours and only transferred a total of 6 TB of data across the platforms. Even with increasing sizes of whole genome datasets, ensemble joint calling of SNVs for low

  12. Differentiating gold nanorod samples using particle size and shape distributions from transmission electron microscope images

    Science.gov (United States)

    Grulke, Eric A.; Wu, Xiaochun; Ji, Yinglu; Buhr, Egbert; Yamamoto, Kazuhiro; Song, Nam Woong; Stefaniak, Aleksandr B.; Schwegler-Berry, Diane; Burchett, Woodrow W.; Lambert, Joshua; Stromberg, Arnold J.

    2018-04-01

    Size and shape distributions of gold nanorod samples are critical to their physico-chemical properties, especially their longitudinal surface plasmon resonance. This interlaboratory comparison study developed methods for measuring and evaluating size and shape distributions for gold nanorod samples using transmission electron microscopy (TEM) images. The objective was to determine whether two different samples, which had different performance attributes in their application, were different with respect to their size and/or shape descriptor distributions. Touching particles in the captured images were identified using a ruggedness shape descriptor. Nanorods could be distinguished from nanocubes using an elongational shape descriptor. A non-parametric statistical test showed that cumulative distributions of an elongational shape descriptor, that is, the aspect ratio, were statistically different between the two samples for all laboratories. While the scale parameters of size and shape distributions were similar for both samples, the width parameters of size and shape distributions were statistically different. This protocol fulfills an important need for a standardized approach to measure gold nanorod size and shape distributions for applications in which quantitative measurements and comparisons are important. Furthermore, the validated protocol workflow can be automated, thus providing consistent and rapid measurements of nanorod size and shape distributions for researchers, regulatory agencies, and industry.

  13. Bayesian sample size determination for cost-effectiveness studies with censored data.

    Directory of Open Access Journals (Sweden)

    Daniel P Beavers

    Full Text Available Cost-effectiveness models are commonly utilized to determine the combined clinical and economic impact of one treatment compared to another. However, most methods for sample size determination of cost-effectiveness studies assume fully observed costs and effectiveness outcomes, which presents challenges for survival-based studies in which censoring exists. We propose a Bayesian method for the design and analysis of cost-effectiveness data in which costs and effectiveness may be censored, and the sample size is approximated for both power and assurance. We explore two parametric models and demonstrate the flexibility of the approach to accommodate a variety of modifications to study assumptions.

  14. Development of sample size allocation program using hypergeometric distribution

    International Nuclear Information System (INIS)

    Kim, Hyun Tae; Kwack, Eun Ho; Park, Wan Soo; Min, Kyung Soo; Park, Chan Sik

    1996-01-01

    The objective of this research is the development of sample allocation program using hypergeometric distribution with objected-oriented method. When IAEA(International Atomic Energy Agency) performs inspection, it simply applies a standard binomial distribution which describes sampling with replacement instead of a hypergeometric distribution which describes sampling without replacement in sample allocation to up to three verification methods. The objective of the IAEA inspection is the timely detection of diversion of significant quantities of nuclear material, therefore game theory is applied to its sampling plan. It is necessary to use hypergeometric distribution directly or approximate distribution to secure statistical accuracy. Improved binomial approximation developed by Mr. J. L. Jaech and correctly applied binomial approximation are more closer to hypergeometric distribution in sample size calculation than the simply applied binomial approximation of the IAEA. Object-oriented programs of 1. sample approximate-allocation with correctly applied standard binomial approximation, 2. sample approximate-allocation with improved binomial approximation, and 3. sample approximate-allocation with hypergeometric distribution were developed with Visual C ++ and corresponding programs were developed with EXCEL(using Visual Basic for Application). 8 tabs., 15 refs. (Author)

  15. Novel joint selection methods can reduce sample size for rheumatoid arthritis clinical trials with ultrasound endpoints.

    Science.gov (United States)

    Allen, John C; Thumboo, Julian; Lye, Weng Kit; Conaghan, Philip G; Chew, Li-Ching; Tan, York Kiat

    2018-03-01

    To determine whether novel methods of selecting joints through (i) ultrasonography (individualized-ultrasound [IUS] method), or (ii) ultrasonography and clinical examination (individualized-composite-ultrasound [ICUS] method) translate into smaller rheumatoid arthritis (RA) clinical trial sample sizes when compared to existing methods utilizing predetermined joint sites for ultrasonography. Cohen's effect size (ES) was estimated (ES^) and a 95% CI (ES^L, ES^U) calculated on a mean change in 3-month total inflammatory score for each method. Corresponding 95% CIs [nL(ES^U), nU(ES^L)] were obtained on a post hoc sample size reflecting the uncertainty in ES^. Sample size calculations were based on a one-sample t-test as the patient numbers needed to provide 80% power at α = 0.05 to reject a null hypothesis H 0 : ES = 0 versus alternative hypotheses H 1 : ES = ES^, ES = ES^L and ES = ES^U. We aimed to provide point and interval estimates on projected sample sizes for future studies reflecting the uncertainty in our study ES^S. Twenty-four treated RA patients were followed up for 3 months. Utilizing the 12-joint approach and existing methods, the post hoc sample size (95% CI) was 22 (10-245). Corresponding sample sizes using ICUS and IUS were 11 (7-40) and 11 (6-38), respectively. Utilizing a seven-joint approach, the corresponding sample sizes using ICUS and IUS methods were nine (6-24) and 11 (6-35), respectively. Our pilot study suggests that sample size for RA clinical trials with ultrasound endpoints may be reduced using the novel methods, providing justification for larger studies to confirm these observations. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  16. The influence of tube voltage and phantom size in computed tomography on the dose-response relationship of dicentrics in human blood samples

    International Nuclear Information System (INIS)

    Jost, G; Pietsch, H; Lengsfeld, P; Voth, M; Schmid, E

    2010-01-01

    The aim of this study was to investigate the dose response relationship of dicentrics in human lymphocytes after CT scans at tube voltages of 80 and 140 kV. Blood samples from a healthy donor placed in tissue equivalent abdomen phantoms of standard, pediatric and adipose sizes were exposed at dose levels up to 0.1 Gy using a 64-slice CT scanner. It was found that both the tube voltage and the phantom size significantly influenced the CT scan-induced linear dose-response relationship of dicentrics in human lymphocytes. Using the same phantom (standard abdomen), 80 kV CT x-rays were biologically more effective than 140 kV CT x-rays. However, it could also be determined that the applied phantom size had much more influence on the biological effectiveness. Obviously, the increasing slopes of the CT scan-induced dose response relationships of dicentrics in human lymphocytes obtained in a pediatric, a standard and an adipose abdomen have been induced by scattering effects of photons, which strongly increase with increasing phantom size.

  17. The influence of tube voltage and phantom size in computed tomography on the dose-response relationship of dicentrics in human blood samples

    Energy Technology Data Exchange (ETDEWEB)

    Jost, G; Pietsch, H [TRG Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Lengsfeld, P; Voth, M [Global Medical Affairs Diagnostic Imaging, Bayer Schering Pharma AG, Berlin (Germany); Schmid, E, E-mail: Ernst.Schmid@lrz.uni-muenchen.d [Institute for Cell Biology, Center for Integrated Protein Science, University of Munich (Germany)

    2010-06-07

    The aim of this study was to investigate the dose response relationship of dicentrics in human lymphocytes after CT scans at tube voltages of 80 and 140 kV. Blood samples from a healthy donor placed in tissue equivalent abdomen phantoms of standard, pediatric and adipose sizes were exposed at dose levels up to 0.1 Gy using a 64-slice CT scanner. It was found that both the tube voltage and the phantom size significantly influenced the CT scan-induced linear dose-response relationship of dicentrics in human lymphocytes. Using the same phantom (standard abdomen), 80 kV CT x-rays were biologically more effective than 140 kV CT x-rays. However, it could also be determined that the applied phantom size had much more influence on the biological effectiveness. Obviously, the increasing slopes of the CT scan-induced dose response relationships of dicentrics in human lymphocytes obtained in a pediatric, a standard and an adipose abdomen have been induced by scattering effects of photons, which strongly increase with increasing phantom size.

  18. Effects of sample size on robustness and prediction accuracy of a prognostic gene signature

    Directory of Open Access Journals (Sweden)

    Kim Seon-Young

    2009-05-01

    Full Text Available Abstract Background Few overlap between independently developed gene signatures and poor inter-study applicability of gene signatures are two of major concerns raised in the development of microarray-based prognostic gene signatures. One recent study suggested that thousands of samples are needed to generate a robust prognostic gene signature. Results A data set of 1,372 samples was generated by combining eight breast cancer gene expression data sets produced using the same microarray platform and, using the data set, effects of varying samples sizes on a few performances of a prognostic gene signature were investigated. The overlap between independently developed gene signatures was increased linearly with more samples, attaining an average overlap of 16.56% with 600 samples. The concordance between predicted outcomes by different gene signatures also was increased with more samples up to 94.61% with 300 samples. The accuracy of outcome prediction also increased with more samples. Finally, analysis using only Estrogen Receptor-positive (ER+ patients attained higher prediction accuracy than using both patients, suggesting that sub-type specific analysis can lead to the development of better prognostic gene signatures Conclusion Increasing sample sizes generated a gene signature with better stability, better concordance in outcome prediction, and better prediction accuracy. However, the degree of performance improvement by the increased sample size was different between the degree of overlap and the degree of concordance in outcome prediction, suggesting that the sample size required for a study should be determined according to the specific aims of the study.

  19. Volatile and non-volatile elements in grain-size separated samples of Apollo 17 lunar soils

    International Nuclear Information System (INIS)

    Giovanoli, R.; Gunten, H.R. von; Kraehenbuehl, U.; Meyer, G.; Wegmueller, F.; Gruetter, A.; Wyttenbach, A.

    1977-01-01

    Three samples of Apollo 17 lunar soils (75081, 72501 and 72461) were separated into 9 grain-size fractions between 540 and 1 μm mean diameter. In order to detect mineral fractionations caused during the separation procedures major elements were determined by instrumental neutron activation analyses performed on small aliquots of the separated samples. Twenty elements were measured in each size fraction using instrumental and radiochemical neutron activation techniques. The concentration of the main elements in sample 75081 does not change with the grain-size. Exceptions are Fe and Ti which decrease slightly and Al which increases slightly with the decrease in the grain-size. These changes in the composition in main elements suggest a decrease in Ilmenite and an increase in Anorthite with decreasing grain-size. However, it can be concluded that the mineral composition of the fractions changes less than a factor of 2. Samples 72501 and 72461 are not yet analyzed for the main elements. (Auth.)

  20. A modified approach to estimating sample size for simple logistic regression with one continuous covariate.

    Science.gov (United States)

    Novikov, I; Fund, N; Freedman, L S

    2010-01-15

    Different methods for the calculation of sample size for simple logistic regression (LR) with one normally distributed continuous covariate give different results. Sometimes the difference can be large. Furthermore, some methods require the user to specify the prevalence of cases when the covariate equals its population mean, rather than the more natural population prevalence. We focus on two commonly used methods and show through simulations that the power for a given sample size may differ substantially from the nominal value for one method, especially when the covariate effect is large, while the other method performs poorly if the user provides the population prevalence instead of the required parameter. We propose a modification of the method of Hsieh et al. that requires specification of the population prevalence and that employs Schouten's sample size formula for a t-test with unequal variances and group sizes. This approach appears to increase the accuracy of the sample size estimates for LR with one continuous covariate.

  1. Three-year-olds obey the sample size principle of induction: the influence of evidence presentation and sample size disparity on young children's generalizations.

    Science.gov (United States)

    Lawson, Chris A

    2014-07-01

    Three experiments with 81 3-year-olds (M=3.62years) examined the conditions that enable young children to use the sample size principle (SSP) of induction-the inductive rule that facilitates generalizations from large rather than small samples of evidence. In Experiment 1, children exhibited the SSP when exemplars were presented sequentially but not when exemplars were presented simultaneously. Results from Experiment 3 suggest that the advantage of sequential presentation is not due to the additional time to process the available input from the two samples but instead may be linked to better memory for specific individuals in the large sample. In addition, findings from Experiments 1 and 2 suggest that adherence to the SSP is mediated by the disparity between presented samples. Overall, these results reveal that the SSP appears early in development and is guided by basic cognitive processes triggered during the acquisition of input. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Sample size methods for estimating HIV incidence from cross-sectional surveys.

    Science.gov (United States)

    Konikoff, Jacob; Brookmeyer, Ron

    2015-12-01

    Understanding HIV incidence, the rate at which new infections occur in populations, is critical for tracking and surveillance of the epidemic. In this article, we derive methods for determining sample sizes for cross-sectional surveys to estimate incidence with sufficient precision. We further show how to specify sample sizes for two successive cross-sectional surveys to detect changes in incidence with adequate power. In these surveys biomarkers such as CD4 cell count, viral load, and recently developed serological assays are used to determine which individuals are in an early disease stage of infection. The total number of individuals in this stage, divided by the number of people who are uninfected, is used to approximate the incidence rate. Our methods account for uncertainty in the durations of time spent in the biomarker defined early disease stage. We find that failure to account for this uncertainty when designing surveys can lead to imprecise estimates of incidence and underpowered studies. We evaluated our sample size methods in simulations and found that they performed well in a variety of underlying epidemics. Code for implementing our methods in R is available with this article at the Biometrics website on Wiley Online Library. © 2015, The International Biometric Society.

  3. Sample size calculations for cluster randomised crossover trials in Australian and New Zealand intensive care research.

    Science.gov (United States)

    Arnup, Sarah J; McKenzie, Joanne E; Pilcher, David; Bellomo, Rinaldo; Forbes, Andrew B

    2018-06-01

    The cluster randomised crossover (CRXO) design provides an opportunity to conduct randomised controlled trials to evaluate low risk interventions in the intensive care setting. Our aim is to provide a tutorial on how to perform a sample size calculation for a CRXO trial, focusing on the meaning of the elements required for the calculations, with application to intensive care trials. We use all-cause in-hospital mortality from the Australian and New Zealand Intensive Care Society Adult Patient Database clinical registry to illustrate the sample size calculations. We show sample size calculations for a two-intervention, two 12-month period, cross-sectional CRXO trial. We provide the formulae, and examples of their use, to determine the number of intensive care units required to detect a risk ratio (RR) with a designated level of power between two interventions for trials in which the elements required for sample size calculations remain constant across all ICUs (unstratified design); and in which there are distinct groups (strata) of ICUs that differ importantly in the elements required for sample size calculations (stratified design). The CRXO design markedly reduces the sample size requirement compared with the parallel-group, cluster randomised design for the example cases. The stratified design further reduces the sample size requirement compared with the unstratified design. The CRXO design enables the evaluation of routinely used interventions that can bring about small, but important, improvements in patient care in the intensive care setting.

  4. Evaluation of pump pulsation in respirable size-selective sampling: part II. Changes in sampling efficiency.

    Science.gov (United States)

    Lee, Eun Gyung; Lee, Taekhee; Kim, Seung Won; Lee, Larry; Flemmer, Michael M; Harper, Martin

    2014-01-01

    This second, and concluding, part of this study evaluated changes in sampling efficiency of respirable size-selective samplers due to air pulsations generated by the selected personal sampling pumps characterized in Part I (Lee E, Lee L, Möhlmann C et al. Evaluation of pump pulsation in respirable size-selective sampling: Part I. Pulsation measurements. Ann Occup Hyg 2013). Nine particle sizes of monodisperse ammonium fluorescein (from 1 to 9 μm mass median aerodynamic diameter) were generated individually by a vibrating orifice aerosol generator from dilute solutions of fluorescein in aqueous ammonia and then injected into an environmental chamber. To collect these particles, 10-mm nylon cyclones, also known as Dorr-Oliver (DO) cyclones, were used with five medium volumetric flow rate pumps. Those were the Apex IS, HFS513, GilAir5, Elite5, and Basic5 pumps, which were found in Part I to generate pulsations of 5% (the lowest), 25%, 30%, 56%, and 70% (the highest), respectively. GK2.69 cyclones were used with the Legacy [pump pulsation (PP) = 15%] and Elite12 (PP = 41%) pumps for collection at high flows. The DO cyclone was also used to evaluate changes in sampling efficiency due to pulse shape. The HFS513 pump, which generates a more complex pulse shape, was compared to a single sine wave fluctuation generated by a piston. The luminescent intensity of the fluorescein extracted from each sample was measured with a luminescence spectrometer. Sampling efficiencies were obtained by dividing the intensity of the fluorescein extracted from the filter placed in a cyclone with the intensity obtained from the filter used with a sharp-edged reference sampler. Then, sampling efficiency curves were generated using a sigmoid function with three parameters and each sampling efficiency curve was compared to that of the reference cyclone by constructing bias maps. In general, no change in sampling efficiency (bias under ±10%) was observed until pulsations exceeded 25% for the

  5. Sample-size effects in fast-neutron gamma-ray production measurements: solid-cylinder samples

    International Nuclear Information System (INIS)

    Smith, D.L.

    1975-09-01

    The effects of geometry, absorption and multiple scattering in (n,Xγ) reaction measurements with solid-cylinder samples are investigated. Both analytical and Monte-Carlo methods are employed in the analysis. Geometric effects are shown to be relatively insignificant except in definition of the scattering angles. However, absorption and multiple-scattering effects are quite important; accurate microscopic differential cross sections can be extracted from experimental data only after a careful determination of corrections for these processes. The results of measurements performed using several natural iron samples (covering a wide range of sizes) confirm validity of the correction procedures described herein. It is concluded that these procedures are reliable whenever sufficiently accurate neutron and photon cross section and angular distribution information is available for the analysis. (13 figures, 5 tables) (auth)

  6. Subclinical delusional ideation and appreciation of sample size and heterogeneity in statistical judgment.

    Science.gov (United States)

    Galbraith, Niall D; Manktelow, Ken I; Morris, Neil G

    2010-11-01

    Previous studies demonstrate that people high in delusional ideation exhibit a data-gathering bias on inductive reasoning tasks. The current study set out to investigate the factors that may underpin such a bias by examining healthy individuals, classified as either high or low scorers on the Peters et al. Delusions Inventory (PDI). More specifically, whether high PDI scorers have a relatively poor appreciation of sample size and heterogeneity when making statistical judgments. In Expt 1, high PDI scorers made higher probability estimates when generalizing from a sample of 1 with regard to the heterogeneous human property of obesity. In Expt 2, this effect was replicated and was also observed in relation to the heterogeneous property of aggression. The findings suggest that delusion-prone individuals are less appreciative of the importance of sample size when making statistical judgments about heterogeneous properties; this may underpin the data gathering bias observed in previous studies. There was some support for the hypothesis that threatening material would exacerbate high PDI scorers' indifference to sample size.

  7. Random sampling technique for ultra-fast computations of molecular opacities for exoplanet atmospheres

    Science.gov (United States)

    Min, M.

    2017-10-01

    Context. Opacities of molecules in exoplanet atmospheres rely on increasingly detailed line-lists for these molecules. The line lists available today contain for many species up to several billions of lines. Computation of the spectral line profile created by pressure and temperature broadening, the Voigt profile, of all of these lines is becoming a computational challenge. Aims: We aim to create a method to compute the Voigt profile in a way that automatically focusses the computation time into the strongest lines, while still maintaining the continuum contribution of the high number of weaker lines. Methods: Here, we outline a statistical line sampling technique that samples the Voigt profile quickly and with high accuracy. The number of samples is adjusted to the strength of the line and the local spectral line density. This automatically provides high accuracy line shapes for strong lines or lines that are spectrally isolated. The line sampling technique automatically preserves the integrated line opacity for all lines, thereby also providing the continuum opacity created by the large number of weak lines at very low computational cost. Results: The line sampling technique is tested for accuracy when computing line spectra and correlated-k tables. Extremely fast computations ( 3.5 × 105 lines per second per core on a standard current day desktop computer) with high accuracy (≤1% almost everywhere) are obtained. A detailed recipe on how to perform the computations is given.

  8. Page sample size in web accessibility testing: how many pages is enough?

    NARCIS (Netherlands)

    Velleman, Eric Martin; van der Geest, Thea

    2013-01-01

    Various countries and organizations use a different sampling approach and sample size of web pages in accessibility conformance tests. We are conducting a systematic analysis to determine how many pages is enough for testing whether a website is compliant with standard accessibility guidelines. This

  9. Cooperative storage of shared files in a parallel computing system with dynamic block size

    Science.gov (United States)

    Bent, John M.; Faibish, Sorin; Grider, Gary

    2015-11-10

    Improved techniques are provided for parallel writing of data to a shared object in a parallel computing system. A method is provided for storing data generated by a plurality of parallel processes to a shared object in a parallel computing system. The method is performed by at least one of the processes and comprises: dynamically determining a block size for storing the data; exchanging a determined amount of the data with at least one additional process to achieve a block of the data having the dynamically determined block size; and writing the block of the data having the dynamically determined block size to a file system. The determined block size comprises, e.g., a total amount of the data to be stored divided by the number of parallel processes. The file system comprises, for example, a log structured virtual parallel file system, such as a Parallel Log-Structured File System (PLFS).

  10. Sensitivity of Mantel Haenszel Model and Rasch Model as Viewed From Sample Size

    OpenAIRE

    ALWI, IDRUS

    2011-01-01

    The aims of this research is to study the sensitivity comparison of Mantel Haenszel and Rasch Model for detection differential item functioning, observed from the sample size. These two differential item functioning (DIF) methods were compared using simulate binary item respon data sets of varying sample size,  200 and 400 examinees were used in the analyses, a detection method of differential item functioning (DIF) based on gender difference. These test conditions were replication 4 tim...

  11. Effect of model choice and sample size on statistical tolerance limits

    International Nuclear Information System (INIS)

    Duran, B.S.; Campbell, K.

    1980-03-01

    Statistical tolerance limits are estimates of large (or small) quantiles of a distribution, quantities which are very sensitive to the shape of the tail of the distribution. The exact nature of this tail behavior cannot be ascertained brom small samples, so statistical tolerance limits are frequently computed using a statistical model chosen on the basis of theoretical considerations or prior experience with similar populations. This report illustrates the effects of such choices on the computations

  12. Research Note Pilot survey to assess sample size for herbaceous ...

    African Journals Online (AJOL)

    A pilot survey to determine sub-sample size (number of point observations per plot) for herbaceous species composition assessments, using a wheel-point apparatus applying the nearest-plant method, was conducted. Three plots differing in species composition on the Zululand coastal plain were selected, and on each plot ...

  13. Convergence of Ground and Excited State Properties of Divacancy Defects in 4H-SiC with Computational Cell Size

    Science.gov (United States)

    2018-03-01

    SiC with Computational Cell Size by Ariana Beste and DeCarlos E Taylor Approved for public release; distribution is unlimited...Laboratory Convergence of Ground and Excited State Properties of Divacancy Defects in 4H-SiC with Computational Cell Size by Ariana Beste...Ground and Excited State Properties of Divacancy Defects in 4H-SiC with Computational Cell Size 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM

  14. Maximum type 1 error rate inflation in multiarmed clinical trials with adaptive interim sample size modifications.

    Science.gov (United States)

    Graf, Alexandra C; Bauer, Peter; Glimm, Ekkehard; Koenig, Franz

    2014-07-01

    Sample size modifications in the interim analyses of an adaptive design can inflate the type 1 error rate, if test statistics and critical boundaries are used in the final analysis as if no modification had been made. While this is already true for designs with an overall change of the sample size in a balanced treatment-control comparison, the inflation can be much larger if in addition a modification of allocation ratios is allowed as well. In this paper, we investigate adaptive designs with several treatment arms compared to a single common control group. Regarding modifications, we consider treatment arm selection as well as modifications of overall sample size and allocation ratios. The inflation is quantified for two approaches: a naive procedure that ignores not only all modifications, but also the multiplicity issue arising from the many-to-one comparison, and a Dunnett procedure that ignores modifications, but adjusts for the initially started multiple treatments. The maximum inflation of the type 1 error rate for such types of design can be calculated by searching for the "worst case" scenarios, that are sample size adaptation rules in the interim analysis that lead to the largest conditional type 1 error rate in any point of the sample space. To show the most extreme inflation, we initially assume unconstrained second stage sample size modifications leading to a large inflation of the type 1 error rate. Furthermore, we investigate the inflation when putting constraints on the second stage sample sizes. It turns out that, for example fixing the sample size of the control group, leads to designs controlling the type 1 error rate. © 2014 The Author. Biometrical Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. A simple nomogram for sample size for estimating sensitivity and specificity of medical tests

    Directory of Open Access Journals (Sweden)

    Malhotra Rajeev

    2010-01-01

    Full Text Available Sensitivity and specificity measure inherent validity of a diagnostic test against a gold standard. Researchers develop new diagnostic methods to reduce the cost, risk, invasiveness, and time. Adequate sample size is a must to precisely estimate the validity of a diagnostic test. In practice, researchers generally decide about the sample size arbitrarily either at their convenience, or from the previous literature. We have devised a simple nomogram that yields statistically valid sample size for anticipated sensitivity or anticipated specificity. MS Excel version 2007 was used to derive the values required to plot the nomogram using varying absolute precision, known prevalence of disease, and 95% confidence level using the formula already available in the literature. The nomogram plot was obtained by suitably arranging the lines and distances to conform to this formula. This nomogram could be easily used to determine the sample size for estimating the sensitivity or specificity of a diagnostic test with required precision and 95% confidence level. Sample size at 90% and 99% confidence level, respectively, can also be obtained by just multiplying 0.70 and 1.75 with the number obtained for the 95% confidence level. A nomogram instantly provides the required number of subjects by just moving the ruler and can be repeatedly used without redoing the calculations. This can also be applied for reverse calculations. This nomogram is not applicable for testing of the hypothesis set-up and is applicable only when both diagnostic test and gold standard results have a dichotomous category.

  16. Estimating sample size for a small-quadrat method of botanical ...

    African Journals Online (AJOL)

    Reports the results of a study conducted to determine an appropriate sample size for a small-quadrat method of botanical survey for application in the Mixed Bushveld of South Africa. Species density and grass density were measured using a small-quadrat method in eight plant communities in the Nylsvley Nature Reserve.

  17. Norm Block Sample Sizes: A Review of 17 Individually Administered Intelligence Tests

    Science.gov (United States)

    Norfolk, Philip A.; Farmer, Ryan L.; Floyd, Randy G.; Woods, Isaac L.; Hawkins, Haley K.; Irby, Sarah M.

    2015-01-01

    The representativeness, recency, and size of norm samples strongly influence the accuracy of inferences drawn from their scores. Inadequate norm samples may lead to inflated or deflated scores for individuals and poorer prediction of developmental and academic outcomes. The purpose of this study was to apply Kranzler and Floyd's method for…

  18. Precision of quantization of the hall conductivity in a finite-size sample: Power law

    International Nuclear Information System (INIS)

    Greshnov, A. A.; Kolesnikova, E. N.; Zegrya, G. G.

    2006-01-01

    A microscopic calculation of the conductivity in the integer quantum Hall effect (IQHE) mode is carried out. The precision of quantization is analyzed for finite-size samples. The precision of quantization shows a power-law dependence on the sample size. A new scaling parameter describing this dependence is introduced. It is also demonstrated that the precision of quantization linearly depends on the ratio between the amplitude of the disorder potential and the cyclotron energy. The data obtained are compared with the results of magnetotransport measurements in mesoscopic samples

  19. Sample size for monitoring sirex populations and their natural enemies

    Directory of Open Access Journals (Sweden)

    Susete do Rocio Chiarello Penteado

    2016-09-01

    Full Text Available The woodwasp Sirex noctilio Fabricius (Hymenoptera: Siricidae was introduced in Brazil in 1988 and became the main pest in pine plantations. It has spread to about 1.000.000 ha, at different population levels, in the states of Rio Grande do Sul, Santa Catarina, Paraná, São Paulo and Minas Gerais. Control is done mainly by using a nematode, Deladenus siricidicola Bedding (Nematoda: Neothylenchidae. The evaluation of the efficiency of natural enemies has been difficult because there are no appropriate sampling systems. This study tested a hierarchical sampling system to define the sample size to monitor the S. noctilio population and the efficiency of their natural enemies, which was found to be perfectly adequate.

  20. Random-effects linear modeling and sample size tables for two special crossover designs of average bioequivalence studies: the four-period, two-sequence, two-formulation and six-period, three-sequence, three-formulation designs.

    Science.gov (United States)

    Diaz, Francisco J; Berg, Michel J; Krebill, Ron; Welty, Timothy; Gidal, Barry E; Alloway, Rita; Privitera, Michael

    2013-12-01

    Due to concern and debate in the epilepsy medical community and to the current interest of the US Food and Drug Administration (FDA) in revising approaches to the approval of generic drugs, the FDA is currently supporting ongoing bioequivalence studies of antiepileptic drugs, the EQUIGEN studies. During the design of these crossover studies, the researchers could not find commercial or non-commercial statistical software that quickly allowed computation of sample sizes for their designs, particularly software implementing the FDA requirement of using random-effects linear models for the analyses of bioequivalence studies. This article presents tables for sample-size evaluations of average bioequivalence studies based on the two crossover designs used in the EQUIGEN studies: the four-period, two-sequence, two-formulation design, and the six-period, three-sequence, three-formulation design. Sample-size computations assume that random-effects linear models are used in bioequivalence analyses with crossover designs. Random-effects linear models have been traditionally viewed by many pharmacologists and clinical researchers as just mathematical devices to analyze repeated-measures data. In contrast, a modern view of these models attributes an important mathematical role in theoretical formulations in personalized medicine to them, because these models not only have parameters that represent average patients, but also have parameters that represent individual patients. Moreover, the notation and language of random-effects linear models have evolved over the years. Thus, another goal of this article is to provide a presentation of the statistical modeling of data from bioequivalence studies that highlights the modern view of these models, with special emphasis on power analyses and sample-size computations.

  1. Collection of size fractionated particulate matter sample for neutron activation analysis in Japan

    International Nuclear Information System (INIS)

    Otoshi, Tsunehiko; Nakamatsu, Hiroaki; Oura, Yasuji; Ebihara, Mitsuru

    2004-01-01

    According to the decision of the 2001 Workshop on Utilization of Research Reactor (Neutron Activation Analysis (NAA) Section), size fractionated particulate matter collection for NAA was started from 2002 at two sites in Japan. The two monitoring sites, ''Tokyo'' and ''Sakata'', were classified into ''urban'' and ''rural''. In each site, two size fractions, namely PM 2-10 '' and PM 2 '' particles (aerodynamic particle size between 2 to 10 micrometer and less than 2 micrometer, respectively) were collected every month on polycarbonate membrane filters. Average concentrations of PM 10 (sum of PM 2-10 and PM 2 samples) during the common sampling period of August to November 2002 in each site were 0.031mg/m 3 in Tokyo, and 0.022mg/m 3 in Sakata. (author)

  2. Assessing the precision of a time-sampling-based study among GPs: balancing sample size and measurement frequency.

    Science.gov (United States)

    van Hassel, Daniël; van der Velden, Lud; de Bakker, Dinny; van der Hoek, Lucas; Batenburg, Ronald

    2017-12-04

    Our research is based on a technique for time sampling, an innovative method for measuring the working hours of Dutch general practitioners (GPs), which was deployed in an earlier study. In this study, 1051 GPs were questioned about their activities in real time by sending them one SMS text message every 3 h during 1 week. The required sample size for this study is important for health workforce planners to know if they want to apply this method to target groups who are hard to reach or if fewer resources are available. In this time-sampling method, however, standard power analyses is not sufficient for calculating the required sample size as this accounts only for sample fluctuation and not for the fluctuation of measurements taken from every participant. We investigated the impact of the number of participants and frequency of measurements per participant upon the confidence intervals (CIs) for the hours worked per week. Statistical analyses of the time-use data we obtained from GPs were performed. Ninety-five percent CIs were calculated, using equations and simulation techniques, for various different numbers of GPs included in the dataset and for various frequencies of measurements per participant. Our results showed that the one-tailed CI, including sample and measurement fluctuation, decreased from 21 until 3 h between one and 50 GPs. As a result of the formulas to calculate CIs, the increase of the precision continued and was lower with the same additional number of GPs. Likewise, the analyses showed how the number of participants required decreased if more measurements per participant were taken. For example, one measurement per 3-h time slot during the week requires 300 GPs to achieve a CI of 1 h, while one measurement per hour requires 100 GPs to obtain the same result. The sample size needed for time-use research based on a time-sampling technique depends on the design and aim of the study. In this paper, we showed how the precision of the

  3. A two-stage Bayesian design with sample size reestimation and subgroup analysis for phase II binary response trials.

    Science.gov (United States)

    Zhong, Wei; Koopmeiners, Joseph S; Carlin, Bradley P

    2013-11-01

    Frequentist sample size determination for binary outcome data in a two-arm clinical trial requires initial guesses of the event probabilities for the two treatments. Misspecification of these event rates may lead to a poor estimate of the necessary sample size. In contrast, the Bayesian approach that considers the treatment effect to be random variable having some distribution may offer a better, more flexible approach. The Bayesian sample size proposed by (Whitehead et al., 2008) for exploratory studies on efficacy justifies the acceptable minimum sample size by a "conclusiveness" condition. In this work, we introduce a new two-stage Bayesian design with sample size reestimation at the interim stage. Our design inherits the properties of good interpretation and easy implementation from Whitehead et al. (2008), generalizes their method to a two-sample setting, and uses a fully Bayesian predictive approach to reduce an overly large initial sample size when necessary. Moreover, our design can be extended to allow patient level covariates via logistic regression, now adjusting sample size within each subgroup based on interim analyses. We illustrate the benefits of our approach with a design in non-Hodgkin lymphoma with a simple binary covariate (patient gender), offering an initial step toward within-trial personalized medicine. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Coalescent: an open-science framework for importance sampling in coalescent theory.

    Science.gov (United States)

    Tewari, Susanta; Spouge, John L

    2015-01-01

    Background. In coalescent theory, computer programs often use importance sampling to calculate likelihoods and other statistical quantities. An importance sampling scheme can exploit human intuition to improve statistical efficiency of computations, but unfortunately, in the absence of general computer frameworks on importance sampling, researchers often struggle to translate new sampling schemes computationally or benchmark against different schemes, in a manner that is reliable and maintainable. Moreover, most studies use computer programs lacking a convenient user interface or the flexibility to meet the current demands of open science. In particular, current computer frameworks can only evaluate the efficiency of a single importance sampling scheme or compare the efficiencies of different schemes in an ad hoc manner. Results. We have designed a general framework (http://coalescent.sourceforge.net; language: Java; License: GPLv3) for importance sampling that computes likelihoods under the standard neutral coalescent model of a single, well-mixed population of constant size over time following infinite sites model of mutation. The framework models the necessary core concepts, comes integrated with several data sets of varying size, implements the standard competing proposals, and integrates tightly with our previous framework for calculating exact probabilities. For a given dataset, it computes the likelihood and provides the maximum likelihood estimate of the mutation parameter. Well-known benchmarks in the coalescent literature validate the accuracy of the framework. The framework provides an intuitive user interface with minimal clutter. For performance, the framework switches automatically to modern multicore hardware, if available. It runs on three major platforms (Windows, Mac and Linux). Extensive tests and coverage make the framework reliable and maintainable. Conclusions. In coalescent theory, many studies of computational efficiency consider only

  5. Coalescent: an open-science framework for importance sampling in coalescent theory

    Directory of Open Access Journals (Sweden)

    Susanta Tewari

    2015-08-01

    Full Text Available Background. In coalescent theory, computer programs often use importance sampling to calculate likelihoods and other statistical quantities. An importance sampling scheme can exploit human intuition to improve statistical efficiency of computations, but unfortunately, in the absence of general computer frameworks on importance sampling, researchers often struggle to translate new sampling schemes computationally or benchmark against different schemes, in a manner that is reliable and maintainable. Moreover, most studies use computer programs lacking a convenient user interface or the flexibility to meet the current demands of open science. In particular, current computer frameworks can only evaluate the efficiency of a single importance sampling scheme or compare the efficiencies of different schemes in an ad hoc manner.Results. We have designed a general framework (http://coalescent.sourceforge.net; language: Java; License: GPLv3 for importance sampling that computes likelihoods under the standard neutral coalescent model of a single, well-mixed population of constant size over time following infinite sites model of mutation. The framework models the necessary core concepts, comes integrated with several data sets of varying size, implements the standard competing proposals, and integrates tightly with our previous framework for calculating exact probabilities. For a given dataset, it computes the likelihood and provides the maximum likelihood estimate of the mutation parameter. Well-known benchmarks in the coalescent literature validate the accuracy of the framework. The framework provides an intuitive user interface with minimal clutter. For performance, the framework switches automatically to modern multicore hardware, if available. It runs on three major platforms (Windows, Mac and Linux. Extensive tests and coverage make the framework reliable and maintainable.Conclusions. In coalescent theory, many studies of computational efficiency

  6. Continuous-Variable Instantaneous Quantum Computing is Hard to Sample.

    Science.gov (United States)

    Douce, T; Markham, D; Kashefi, E; Diamanti, E; Coudreau, T; Milman, P; van Loock, P; Ferrini, G

    2017-02-17

    Instantaneous quantum computing is a subuniversal quantum complexity class, whose circuits have proven to be hard to simulate classically in the discrete-variable realm. We extend this proof to the continuous-variable (CV) domain by using squeezed states and homodyne detection, and by exploring the properties of postselected circuits. In order to treat postselection in CVs, we consider finitely resolved homodyne detectors, corresponding to a realistic scheme based on discrete probability distributions of the measurement outcomes. The unavoidable errors stemming from the use of finitely squeezed states are suppressed through a qubit-into-oscillator Gottesman-Kitaev-Preskill encoding of quantum information, which was previously shown to enable fault-tolerant CV quantum computation. Finally, we show that, in order to render postselected computational classes in CVs meaningful, a logarithmic scaling of the squeezing parameter with the circuit size is necessary, translating into a polynomial scaling of the input energy.

  7. Effects of sample size and sampling frequency on studies of brown bear home ranges and habitat use

    Science.gov (United States)

    Arthur, Steve M.; Schwartz, Charles C.

    1999-01-01

    We equipped 9 brown bears (Ursus arctos) on the Kenai Peninsula, Alaska, with collars containing both conventional very-high-frequency (VHF) transmitters and global positioning system (GPS) receivers programmed to determine an animal's position at 5.75-hr intervals. We calculated minimum convex polygon (MCP) and fixed and adaptive kernel home ranges for randomly-selected subsets of the GPS data to examine the effects of sample size on accuracy and precision of home range estimates. We also compared results obtained by weekly aerial radiotracking versus more frequent GPS locations to test for biases in conventional radiotracking data. Home ranges based on the MCP were 20-606 km2 (x = 201) for aerial radiotracking data (n = 12-16 locations/bear) and 116-1,505 km2 (x = 522) for the complete GPS data sets (n = 245-466 locations/bear). Fixed kernel home ranges were 34-955 km2 (x = 224) for radiotracking data and 16-130 km2 (x = 60) for the GPS data. Differences between means for radiotracking and GPS data were due primarily to the larger samples provided by the GPS data. Means did not differ between radiotracking data and equivalent-sized subsets of GPS data (P > 0.10). For the MCP, home range area increased and variability decreased asymptotically with number of locations. For the kernel models, both area and variability decreased with increasing sample size. Simulations suggested that the MCP and kernel models required >60 and >80 locations, respectively, for estimates to be both accurate (change in area bears. Our results suggest that the usefulness of conventional radiotracking data may be limited by potential biases and variability due to small samples. Investigators that use home range estimates in statistical tests should consider the effects of variability of those estimates. Use of GPS-equipped collars can facilitate obtaining larger samples of unbiased data and improve accuracy and precision of home range estimates.

  8. Modified FlowCAM procedure for quantifying size distribution of zooplankton with sample recycling capacity.

    Directory of Open Access Journals (Sweden)

    Esther Wong

    Full Text Available We have developed a modified FlowCAM procedure for efficiently quantifying the size distribution of zooplankton. The modified method offers the following new features: 1 prevents animals from settling and clogging with constant bubbling in the sample container; 2 prevents damage to sample animals and facilitates recycling by replacing the built-in peristaltic pump with an external syringe pump, in order to generate negative pressure, creates a steady flow by drawing air from the receiving conical flask (i.e. vacuum pump, and transfers plankton from the sample container toward the main flowcell of the imaging system and finally into the receiving flask; 3 aligns samples in advance of imaging and prevents clogging with an additional flowcell placed ahead of the main flowcell. These modifications were designed to overcome the difficulties applying the standard FlowCAM procedure to studies where the number of individuals per sample is small, and since the FlowCAM can only image a subset of a sample. Our effective recycling procedure allows users to pass the same sample through the FlowCAM many times (i.e. bootstrapping the sample in order to generate a good size distribution. Although more advanced FlowCAM models are equipped with syringe pump and Field of View (FOV flowcells which can image all particles passing through the flow field; we note that these advanced setups are very expensive, offer limited syringe and flowcell sizes, and do not guarantee recycling. In contrast, our modifications are inexpensive and flexible. Finally, we compared the biovolumes estimated by automated FlowCAM image analysis versus conventional manual measurements, and found that the size of an individual zooplankter can be estimated by the FlowCAM image system after ground truthing.

  9. Estimation of sample size and testing power (part 6).

    Science.gov (United States)

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2012-03-01

    The design of one factor with k levels (k ≥ 3) refers to the research that only involves one experimental factor with k levels (k ≥ 3), and there is no arrangement for other important non-experimental factors. This paper introduces the estimation of sample size and testing power for quantitative data and qualitative data having a binary response variable with the design of one factor with k levels (k ≥ 3).

  10. On the Structure of Cortical Microcircuits Inferred from Small Sample Sizes.

    Science.gov (United States)

    Vegué, Marina; Perin, Rodrigo; Roxin, Alex

    2017-08-30

    The structure in cortical microcircuits deviates from what would be expected in a purely random network, which has been seen as evidence of clustering. To address this issue, we sought to reproduce the nonrandom features of cortical circuits by considering several distinct classes of network topology, including clustered networks, networks with distance-dependent connectivity, and those with broad degree distributions. To our surprise, we found that all of these qualitatively distinct topologies could account equally well for all reported nonrandom features despite being easily distinguishable from one another at the network level. This apparent paradox was a consequence of estimating network properties given only small sample sizes. In other words, networks that differ markedly in their global structure can look quite similar locally. This makes inferring network structure from small sample sizes, a necessity given the technical difficulty inherent in simultaneous intracellular recordings, problematic. We found that a network statistic called the sample degree correlation (SDC) overcomes this difficulty. The SDC depends only on parameters that can be estimated reliably given small sample sizes and is an accurate fingerprint of every topological family. We applied the SDC criterion to data from rat visual and somatosensory cortex and discovered that the connectivity was not consistent with any of these main topological classes. However, we were able to fit the experimental data with a more general network class, of which all previous topologies were special cases. The resulting network topology could be interpreted as a combination of physical spatial dependence and nonspatial, hierarchical clustering. SIGNIFICANCE STATEMENT The connectivity of cortical microcircuits exhibits features that are inconsistent with a simple random network. Here, we show that several classes of network models can account for this nonrandom structure despite qualitative differences in

  11. Particle Sampling and Real Time Size Distribution Measurement in H2/O2/TEOS Diffusion Flame

    International Nuclear Information System (INIS)

    Ahn, K.H.; Jung, C.H.; Choi, M.; Lee, J.S.

    2001-01-01

    Growth characteristics of silica particles have been studied experimentally using in situ particle sampling technique from H 2 /O 2 /Tetraethylorthosilicate (TEOS) diffusion flame with carefully devised sampling probe. The particle morphology and the size comparisons are made between the particles sampled by the local thermophoretic method from the inside of the flame and by the electrostatic collector sampling method after the dilution sampling probe. The Transmission Electron Microscope (TEM) image processed data of these two sampling techniques are compared with Scanning Mobility Particle Sizer (SMPS) measurement. TEM image analysis of two sampling methods showed a good agreement with SMPS measurement. The effects of flame conditions and TEOS flow rates on silica particle size distributions are also investigated using the new particle dilution sampling probe. It is found that the particle size distribution characteristics and morphology are mostly governed by the coagulation process and sintering process in the flame. As the flame temperature increases, the effect of coalescence or sintering becomes an important particle growth mechanism which reduces the coagulation process. However, if the flame temperature is not high enough to sinter the aggregated particles then the coagulation process is a dominant particle growth mechanism. In a certain flame condition a secondary particle formation is observed which results in a bimodal particle size distribution

  12. The Sample Size Influence in the Accuracy of the Image Classification of the Remote Sensing

    Directory of Open Access Journals (Sweden)

    Thomaz C. e C. da Costa

    2004-12-01

    Full Text Available Landuse/landcover maps produced by classification of remote sensing images incorporate uncertainty. This uncertainty is measured by accuracy indices using reference samples. The size of the reference sample is defined by approximation by a binomial function without the use of a pilot sample. This way the accuracy are not estimated, but fixed a priori. In case of divergency between the estimated and a priori accuracy the error of the sampling will deviate from the expected error. The size using pilot sample (theorically correct procedure justify when haven´t estimate of accuracy for work area, referent the product remote sensing utility.

  13. Fitting models of continuous trait evolution to incompletely sampled comparative data using approximate Bayesian computation.

    Science.gov (United States)

    Slater, Graham J; Harmon, Luke J; Wegmann, Daniel; Joyce, Paul; Revell, Liam J; Alfaro, Michael E

    2012-03-01

    In recent years, a suite of methods has been developed to fit multiple rate models to phylogenetic comparative data. However, most methods have limited utility at broad phylogenetic scales because they typically require complete sampling of both the tree and the associated phenotypic data. Here, we develop and implement a new, tree-based method called MECCA (Modeling Evolution of Continuous Characters using ABC) that uses a hybrid likelihood/approximate Bayesian computation (ABC)-Markov-Chain Monte Carlo approach to simultaneously infer rates of diversification and trait evolution from incompletely sampled phylogenies and trait data. We demonstrate via simulation that MECCA has considerable power to choose among single versus multiple evolutionary rate models, and thus can be used to test hypotheses about changes in the rate of trait evolution across an incomplete tree of life. We finally apply MECCA to an empirical example of body size evolution in carnivores, and show that there is no evidence for an elevated rate of body size evolution in the pinnipeds relative to terrestrial carnivores. ABC approaches can provide a useful alternative set of tools for future macroevolutionary studies where likelihood-dependent approaches are lacking. © 2011 The Author(s). Evolution© 2011 The Society for the Study of Evolution.

  14. Superior model for fault tolerance computation in designing nano-sized circuit systems

    Energy Technology Data Exchange (ETDEWEB)

    Singh, N. S. S., E-mail: narinderjit@petronas.com.my; Muthuvalu, M. S., E-mail: msmuthuvalu@gmail.com [Fundamental and Applied Sciences Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, Perak (Malaysia); Asirvadam, V. S., E-mail: vijanth-sagayan@petronas.com.my [Electrical and Electronics Engineering Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, Perak (Malaysia)

    2014-10-24

    As CMOS technology scales nano-metrically, reliability turns out to be a decisive subject in the design methodology of nano-sized circuit systems. As a result, several computational approaches have been developed to compute and evaluate reliability of desired nano-electronic circuits. The process of computing reliability becomes very troublesome and time consuming as the computational complexity build ups with the desired circuit size. Therefore, being able to measure reliability instantly and superiorly is fast becoming necessary in designing modern logic integrated circuits. For this purpose, the paper firstly looks into the development of an automated reliability evaluation tool based on the generalization of Probabilistic Gate Model (PGM) and Boolean Difference-based Error Calculator (BDEC) models. The Matlab-based tool allows users to significantly speed-up the task of reliability analysis for very large number of nano-electronic circuits. Secondly, by using the developed automated tool, the paper explores into a comparative study involving reliability computation and evaluation by PGM and, BDEC models for different implementations of same functionality circuits. Based on the reliability analysis, BDEC gives exact and transparent reliability measures, but as the complexity of the same functionality circuits with respect to gate error increases, reliability measure by BDEC tends to be lower than the reliability measure by PGM. The lesser reliability measure by BDEC is well explained in this paper using distribution of different signal input patterns overtime for same functionality circuits. Simulation results conclude that the reliability measure by BDEC depends not only on faulty gates but it also depends on circuit topology, probability of input signals being one or zero and also probability of error on signal lines.

  15. Superior model for fault tolerance computation in designing nano-sized circuit systems

    International Nuclear Information System (INIS)

    Singh, N. S. S.; Muthuvalu, M. S.; Asirvadam, V. S.

    2014-01-01

    As CMOS technology scales nano-metrically, reliability turns out to be a decisive subject in the design methodology of nano-sized circuit systems. As a result, several computational approaches have been developed to compute and evaluate reliability of desired nano-electronic circuits. The process of computing reliability becomes very troublesome and time consuming as the computational complexity build ups with the desired circuit size. Therefore, being able to measure reliability instantly and superiorly is fast becoming necessary in designing modern logic integrated circuits. For this purpose, the paper firstly looks into the development of an automated reliability evaluation tool based on the generalization of Probabilistic Gate Model (PGM) and Boolean Difference-based Error Calculator (BDEC) models. The Matlab-based tool allows users to significantly speed-up the task of reliability analysis for very large number of nano-electronic circuits. Secondly, by using the developed automated tool, the paper explores into a comparative study involving reliability computation and evaluation by PGM and, BDEC models for different implementations of same functionality circuits. Based on the reliability analysis, BDEC gives exact and transparent reliability measures, but as the complexity of the same functionality circuits with respect to gate error increases, reliability measure by BDEC tends to be lower than the reliability measure by PGM. The lesser reliability measure by BDEC is well explained in this paper using distribution of different signal input patterns overtime for same functionality circuits. Simulation results conclude that the reliability measure by BDEC depends not only on faulty gates but it also depends on circuit topology, probability of input signals being one or zero and also probability of error on signal lines

  16. Evaluation of 1H NMR relaxometry for the assessment of pore size distribution in soil samples

    NARCIS (Netherlands)

    Jaeger, F.; Bowe, S.; As, van H.; Schaumann, G.E.

    2009-01-01

    1H NMR relaxometry is used in earth science as a non-destructive and time-saving method to determine pore size distributions (PSD) in porous media with pore sizes ranging from nm to mm. This is a broader range than generally reported for results from X-ray computed tomography (X-ray CT) scanning,

  17. Assessing terpene content variability of whitebark pine in order to estimate representative sample size

    Directory of Open Access Journals (Sweden)

    Stefanović Milena

    2013-01-01

    Full Text Available In studies of population variability, particular attention has to be paid to the selection of a representative sample. The aim of this study was to assess the size of the new representative sample on the basis of the variability of chemical content of the initial sample on the example of a whitebark pine population. Statistical analysis included the content of 19 characteristics (terpene hydrocarbons and their derivates of the initial sample of 10 elements (trees. It was determined that the new sample should contain 20 trees so that the mean value calculated from it represents a basic set with a probability higher than 95 %. Determination of the lower limit of the representative sample size that guarantees a satisfactory reliability of generalization proved to be very important in order to achieve cost efficiency of the research. [Projekat Ministarstva nauke Republike Srbije, br. OI-173011, br. TR-37002 i br. III-43007

  18. Methodology for sample preparation and size measurement of commercial ZnO nanoparticles

    Directory of Open Access Journals (Sweden)

    Pei-Jia Lu

    2018-04-01

    Full Text Available This study discusses the strategies on sample preparation to acquire images with sufficient quality for size characterization by scanning electron microscope (SEM using two commercial ZnO nanoparticles of different surface properties as a demonstration. The central idea is that micrometer sized aggregates of ZnO in powdered forms need to firstly be broken down to nanosized particles through an appropriate process to generate nanoparticle dispersion before being deposited on a flat surface for SEM observation. Analytical tools such as contact angle, dynamic light scattering and zeta potential have been utilized to optimize the procedure for sample preparation and to check the quality of the results. Meanwhile, measurements of zeta potential values on flat surfaces also provide critical information and save lots of time and efforts in selection of suitable substrate for particles of different properties to be attracted and kept on the surface without further aggregation. This simple, low-cost methodology can be generally applied on size characterization of commercial ZnO nanoparticles with limited information from vendors. Keywords: Zinc oxide, Nanoparticles, Methodology

  19. Evaluation of Approaches to Analyzing Continuous Correlated Eye Data When Sample Size Is Small.

    Science.gov (United States)

    Huang, Jing; Huang, Jiayan; Chen, Yong; Ying, Gui-Shuang

    2018-02-01

    To evaluate the performance of commonly used statistical methods for analyzing continuous correlated eye data when sample size is small. We simulated correlated continuous data from two designs: (1) two eyes of a subject in two comparison groups; (2) two eyes of a subject in the same comparison group, under various sample size (5-50), inter-eye correlation (0-0.75) and effect size (0-0.8). Simulated data were analyzed using paired t-test, two sample t-test, Wald test and score test using the generalized estimating equations (GEE) and F-test using linear mixed effects model (LMM). We compared type I error rates and statistical powers, and demonstrated analysis approaches through analyzing two real datasets. In design 1, paired t-test and LMM perform better than GEE, with nominal type 1 error rate and higher statistical power. In design 2, no test performs uniformly well: two sample t-test (average of two eyes or a random eye) achieves better control of type I error but yields lower statistical power. In both designs, the GEE Wald test inflates type I error rate and GEE score test has lower power. When sample size is small, some commonly used statistical methods do not perform well. Paired t-test and LMM perform best when two eyes of a subject are in two different comparison groups, and t-test using the average of two eyes performs best when the two eyes are in the same comparison group. When selecting the appropriate analysis approach the study design should be considered.

  20. Impact of sample size on principal component analysis ordination of an environmental data set: effects on eigenstructure

    Directory of Open Access Journals (Sweden)

    Shaukat S. Shahid

    2016-06-01

    Full Text Available In this study, we used bootstrap simulation of a real data set to investigate the impact of sample size (N = 20, 30, 40 and 50 on the eigenvalues and eigenvectors resulting from principal component analysis (PCA. For each sample size, 100 bootstrap samples were drawn from environmental data matrix pertaining to water quality variables (p = 22 of a small data set comprising of 55 samples (stations from where water samples were collected. Because in ecology and environmental sciences the data sets are invariably small owing to high cost of collection and analysis of samples, we restricted our study to relatively small sample sizes. We focused attention on comparison of first 6 eigenvectors and first 10 eigenvalues. Data sets were compared using agglomerative cluster analysis using Ward’s method that does not require any stringent distributional assumptions.

  1. Unbiased tensor-based morphometry: improved robustness and sample size estimates for Alzheimer's disease clinical trials.

    Science.gov (United States)

    Hua, Xue; Hibar, Derrek P; Ching, Christopher R K; Boyle, Christina P; Rajagopalan, Priya; Gutman, Boris A; Leow, Alex D; Toga, Arthur W; Jack, Clifford R; Harvey, Danielle; Weiner, Michael W; Thompson, Paul M

    2013-02-01

    Various neuroimaging measures are being evaluated for tracking Alzheimer's disease (AD) progression in therapeutic trials, including measures of structural brain change based on repeated scanning of patients with magnetic resonance imaging (MRI). Methods to compute brain change must be robust to scan quality. Biases may arise if any scans are thrown out, as this can lead to the true changes being overestimated or underestimated. Here we analyzed the full MRI dataset from the first phase of Alzheimer's Disease Neuroimaging Initiative (ADNI-1) from the first phase of Alzheimer's Disease Neuroimaging Initiative (ADNI-1) and assessed several sources of bias that can arise when tracking brain changes with structural brain imaging methods, as part of a pipeline for tensor-based morphometry (TBM). In all healthy subjects who completed MRI scanning at screening, 6, 12, and 24months, brain atrophy was essentially linear with no detectable bias in longitudinal measures. In power analyses for clinical trials based on these change measures, only 39AD patients and 95 mild cognitive impairment (MCI) subjects were needed for a 24-month trial to detect a 25% reduction in the average rate of change using a two-sided test (α=0.05, power=80%). Further sample size reductions were achieved by stratifying the data into Apolipoprotein E (ApoE) ε4 carriers versus non-carriers. We show how selective data exclusion affects sample size estimates, motivating an objective comparison of different analysis techniques based on statistical power and robustness. TBM is an unbiased, robust, high-throughput imaging surrogate marker for large, multi-site neuroimaging studies and clinical trials of AD and MCI. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Assessing the impact of large-scale computing on the size and complexity of first-principles electromagnetic models

    International Nuclear Information System (INIS)

    Miller, E.K.

    1990-01-01

    There is a growing need to determine the electromagnetic performance of increasingly complex systems at ever higher frequencies. The ideal approach would be some appropriate combination of measurement, analysis, and computation so that system design and assessment can be achieved to a needed degree of accuracy at some acceptable cost. Both measurement and computation benefit from the continuing growth in computer power that, since the early 1950s, has increased by a factor of more than a million in speed and storage. For example, a CRAY2 has an effective throughput (not the clock rate) of about 10 11 floating-point operations (FLOPs) per hour compared with the approximate 10 5 provided by the UNIVAC-1. The purpose of this discussion is to illustrate the computational complexity of modeling large (in wavelengths) electromagnetic problems. In particular the author makes the point that simply relying on faster computers for increasing the size and complexity of problems that can be modeled is less effective than might be anticipated from this raw increase in computer throughput. He suggests that rather than depending on faster computers alone, various analytical and numerical alternatives need development for reducing the overall FLOP count required to acquire the information desired. One approach is to decrease the operation count of the basic model computation itself, by reducing the order of the frequency dependence of the various numerical operations or their multiplying coefficients. Another is to decrease the number of model evaluations that are needed, an example being the number of frequency samples required to define a wideband response, by using an auxiliary model of the expected behavior. 11 refs., 5 figs., 2 tabs

  3. Effect size calculation in meta-analyses of psychotherapy outcome research.

    Science.gov (United States)

    Hoyt, William T; Del Re, A C

    2018-05-01

    Meta-analysis of psychotherapy intervention research normally examines differences between treatment groups and some form of comparison group (e.g., wait list control; alternative treatment group). The effect of treatment is normally quantified as a standardized mean difference (SMD). We describe procedures for computing unbiased estimates of the population SMD from sample data (e.g., group Ms and SDs), and provide guidance about a number of complications that may arise related to effect size computation. These complications include (a) incomplete data in research reports; (b) use of baseline data in computing SMDs and estimating the population standard deviation (σ); (c) combining effect size data from studies using different research designs; and (d) appropriate techniques for analysis of data from studies providing multiple estimates of the effect of interest (i.e., dependent effect sizes). Clinical or Methodological Significance of this article: Meta-analysis is a set of techniques for producing valid summaries of existing research. The initial computational step for meta-analyses of research on intervention outcomes involves computing an effect size quantifying the change attributable to the intervention. We discuss common issues in the computation of effect sizes and provide recommended procedures to address them.

  4. B-graph sampling to estimate the size of a hidden population

    NARCIS (Netherlands)

    Spreen, M.; Bogaerts, S.

    2015-01-01

    Link-tracing designs are often used to estimate the size of hidden populations by utilizing the relational links between their members. A major problem in studies of hidden populations is the lack of a convenient sampling frame. The most frequently applied design in studies of hidden populations is

  5. X-ray image processing software for computing object size and object location coordinates from acquired optical and x-ray images

    International Nuclear Information System (INIS)

    Tiwari, Akash; Tiwari, Shyam Sunder; Tiwari, Railesha; Panday, Lokesh; Panday, Jeet; Suri, Nitin

    2004-01-01

    X-ray and Visible image data processing software has been developed in Visual Basic for real time online and offline image information processing for NDT and Medical Applications. Software computes two dimension image size parameters from its sharp boundary lines by raster scanning the image contrast data. Code accepts bit map image data and hunts for multiple tumors of different sizes that may be present in the image definition and then computes size of each tumor and locates its approximate center for registering its location coordinates. Presence of foreign metal and glass balls industrial product such as chocolate and other food items imaged out using x-ray imaging technique are detected by the software and their size and position co-ordinates are computed by the software. Paper discusses ways and means to compute size and coordinated of air bubble like objects present in the x-ray and optical images and their multiple existences in image of interest. (author)

  6. Sample sizing of biological materials analyzed by energy dispersion X-ray fluorescence

    International Nuclear Information System (INIS)

    Paiva, Jose D.S.; Franca, Elvis J.; Magalhaes, Marcelo R.L.; Almeida, Marcio E.S.; Hazin, Clovis A.

    2013-01-01

    Analytical portions used in chemical analyses are usually less than 1g. Errors resulting from the sampling are barely evaluated, since this type of study is a time-consuming procedure, with high costs for the chemical analysis of large number of samples. The energy dispersion X-ray fluorescence - EDXRF is a non-destructive and fast analytical technique with the possibility of determining several chemical elements. Therefore, the aim of this study was to provide information on the minimum analytical portion for quantification of chemical elements in biological matrices using EDXRF. Three species were sampled in mangroves from the Pernambuco, Brazil. Tree leaves were washed with distilled water, oven-dried at 60 deg C and milled until 0.5 mm particle size. Ten test-portions of approximately 500 mg for each species were transferred to vials sealed with polypropylene film. The quality of the analytical procedure was evaluated from the reference materials IAEA V10 Hay Powder, SRM 2976 Apple Leaves. After energy calibration, all samples were analyzed under vacuum for 100 seconds for each group of chemical elements. The voltage used was 15 kV and 50 kV for chemical elements of atomic number lower than 22 and the others, respectively. For the best analytical conditions, EDXRF was capable of estimating the sample size uncertainty for further determination of chemical elements in leaves. (author)

  7. Sample sizing of biological materials analyzed by energy dispersion X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, Jose D.S.; Franca, Elvis J.; Magalhaes, Marcelo R.L.; Almeida, Marcio E.S.; Hazin, Clovis A., E-mail: dan-paiva@hotmail.com, E-mail: ejfranca@cnen.gov.br, E-mail: marcelo_rlm@hotmail.com, E-mail: maensoal@yahoo.com.br, E-mail: chazin@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2013-07-01

    Analytical portions used in chemical analyses are usually less than 1g. Errors resulting from the sampling are barely evaluated, since this type of study is a time-consuming procedure, with high costs for the chemical analysis of large number of samples. The energy dispersion X-ray fluorescence - EDXRF is a non-destructive and fast analytical technique with the possibility of determining several chemical elements. Therefore, the aim of this study was to provide information on the minimum analytical portion for quantification of chemical elements in biological matrices using EDXRF. Three species were sampled in mangroves from the Pernambuco, Brazil. Tree leaves were washed with distilled water, oven-dried at 60 deg C and milled until 0.5 mm particle size. Ten test-portions of approximately 500 mg for each species were transferred to vials sealed with polypropylene film. The quality of the analytical procedure was evaluated from the reference materials IAEA V10 Hay Powder, SRM 2976 Apple Leaves. After energy calibration, all samples were analyzed under vacuum for 100 seconds for each group of chemical elements. The voltage used was 15 kV and 50 kV for chemical elements of atomic number lower than 22 and the others, respectively. For the best analytical conditions, EDXRF was capable of estimating the sample size uncertainty for further determination of chemical elements in leaves. (author)

  8. Reliable calculation in probabilistic logic: Accounting for small sample size and model uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Ferson, S. [Applied Biomathematics, Setauket, NY (United States)

    1996-12-31

    A variety of practical computational problems arise in risk and safety assessments, forensic statistics and decision analyses in which the probability of some event or proposition E is to be estimated from the probabilities of a finite list of related subevents or propositions F,G,H,.... In practice, the analyst`s knowledge may be incomplete in two ways. First, the probabilities of the subevents may be imprecisely known from statistical estimations, perhaps based on very small sample sizes. Second, relationships among the subevents may be known imprecisely. For instance, there may be only limited information about their stochastic dependencies. Representing probability estimates as interval ranges on has been suggested as a way to address the first source of imprecision. A suite of AND, OR and NOT operators defined with reference to the classical Frochet inequalities permit these probability intervals to be used in calculations that address the second source of imprecision, in many cases, in a best possible way. Using statistical confidence intervals as inputs unravels the closure properties of this approach however, requiring that probability estimates be characterized by a nested stack of intervals for all possible levels of statistical confidence, from a point estimate (0% confidence) to the entire unit interval (100% confidence). The corresponding logical operations implied by convolutive application of the logical operators for every possible pair of confidence intervals reduces by symmetry to a manageably simple level-wise iteration. The resulting calculus can be implemented in software that allows users to compute comprehensive and often level-wise best possible bounds on probabilities for logical functions of events.

  9. R2 effect-size measures for mediation analysis.

    Science.gov (United States)

    Fairchild, Amanda J; Mackinnon, David P; Taborga, Marcia P; Taylor, Aaron B

    2009-05-01

    R(2) effect-size measures are presented to assess variance accounted for in mediation models. The measures offer a means to evaluate both component paths and the overall mediated effect in mediation models. Statistical simulation results indicate acceptable bias across varying parameter and sample-size combinations. The measures are applied to a real-world example using data from a team-based health promotion program to improve the nutrition and exercise habits of firefighters. SAS and SPSS computer code are also provided for researchers to compute the measures in their own data.

  10. R2 effect-size measures for mediation analysis

    Science.gov (United States)

    Fairchild, Amanda J.; MacKinnon, David P.; Taborga, Marcia P.; Taylor, Aaron B.

    2010-01-01

    R2 effect-size measures are presented to assess variance accounted for in mediation models. The measures offer a means to evaluate both component paths and the overall mediated effect in mediation models. Statistical simulation results indicate acceptable bias across varying parameter and sample-size combinations. The measures are applied to a real-world example using data from a team-based health promotion program to improve the nutrition and exercise habits of firefighters. SAS and SPSS computer code are also provided for researchers to compute the measures in their own data. PMID:19363189

  11. Sample size calculation while controlling false discovery rate for differential expression analysis with RNA-sequencing experiments.

    Science.gov (United States)

    Bi, Ran; Liu, Peng

    2016-03-31

    RNA-Sequencing (RNA-seq) experiments have been popularly applied to transcriptome studies in recent years. Such experiments are still relatively costly. As a result, RNA-seq experiments often employ a small number of replicates. Power analysis and sample size calculation are challenging in the context of differential expression analysis with RNA-seq data. One challenge is that there are no closed-form formulae to calculate power for the popularly applied tests for differential expression analysis. In addition, false discovery rate (FDR), instead of family-wise type I error rate, is controlled for the multiple testing error in RNA-seq data analysis. So far, there are very few proposals on sample size calculation for RNA-seq experiments. In this paper, we propose a procedure for sample size calculation while controlling FDR for RNA-seq experimental design. Our procedure is based on the weighted linear model analysis facilitated by the voom method which has been shown to have competitive performance in terms of power and FDR control for RNA-seq differential expression analysis. We derive a method that approximates the average power across the differentially expressed genes, and then calculate the sample size to achieve a desired average power while controlling FDR. Simulation results demonstrate that the actual power of several popularly applied tests for differential expression is achieved and is close to the desired power for RNA-seq data with sample size calculated based on our method. Our proposed method provides an efficient algorithm to calculate sample size while controlling FDR for RNA-seq experimental design. We also provide an R package ssizeRNA that implements our proposed method and can be downloaded from the Comprehensive R Archive Network ( http://cran.r-project.org ).

  12. Estimating sample size for landscape-scale mark-recapture studies of North American migratory tree bats

    Science.gov (United States)

    Ellison, Laura E.; Lukacs, Paul M.

    2014-01-01

    Concern for migratory tree-roosting bats in North America has grown because of possible population declines from wind energy development. This concern has driven interest in estimating population-level changes. Mark-recapture methodology is one possible analytical framework for assessing bat population changes, but sample size requirements to produce reliable estimates have not been estimated. To illustrate the sample sizes necessary for a mark-recapture-based monitoring program we conducted power analyses using a statistical model that allows reencounters of live and dead marked individuals. We ran 1,000 simulations for each of five broad sample size categories in a Burnham joint model, and then compared the proportion of simulations in which 95% confidence intervals overlapped between and among years for a 4-year study. Additionally, we conducted sensitivity analyses of sample size to various capture probabilities and recovery probabilities. More than 50,000 individuals per year would need to be captured and released to accurately determine 10% and 15% declines in annual survival. To detect more dramatic declines of 33% or 50% survival over four years, then sample sizes of 25,000 or 10,000 per year, respectively, would be sufficient. Sensitivity analyses reveal that increasing recovery of dead marked individuals may be more valuable than increasing capture probability of marked individuals. Because of the extraordinary effort that would be required, we advise caution should such a mark-recapture effort be initiated because of the difficulty in attaining reliable estimates. We make recommendations for what techniques show the most promise for mark-recapture studies of bats because some techniques violate the assumptions of mark-recapture methodology when used to mark bats.

  13. Sample size determination for a three-arm equivalence trial of Poisson and negative binomial responses.

    Science.gov (United States)

    Chang, Yu-Wei; Tsong, Yi; Zhao, Zhigen

    2017-01-01

    Assessing equivalence or similarity has drawn much attention recently as many drug products have lost or will lose their patents in the next few years, especially certain best-selling biologics. To claim equivalence between the test treatment and the reference treatment when assay sensitivity is well established from historical data, one has to demonstrate both superiority of the test treatment over placebo and equivalence between the test treatment and the reference treatment. Thus, there is urgency for practitioners to derive a practical way to calculate sample size for a three-arm equivalence trial. The primary endpoints of a clinical trial may not always be continuous, but may be discrete. In this paper, the authors derive power function and discuss sample size requirement for a three-arm equivalence trial with Poisson and negative binomial clinical endpoints. In addition, the authors examine the effect of the dispersion parameter on the power and the sample size by varying its coefficient from small to large. In extensive numerical studies, the authors demonstrate that required sample size heavily depends on the dispersion parameter. Therefore, misusing a Poisson model for negative binomial data may easily lose power up to 20%, depending on the value of the dispersion parameter.

  14. Computer system for environmental sample analysis and data storage and analysis

    International Nuclear Information System (INIS)

    Brauer, F.P.; Fager, J.E.

    1976-01-01

    A mini-computer based environmental sample analysis and data storage system has been developed. The system is used for analytical data acquisition, computation, storage of analytical results, and tabulation of selected or derived results for data analysis, interpretation and reporting. This paper discussed the structure, performance and applications of the system

  15. The impact of sample size and marker selection on the study of haplotype structures

    Directory of Open Access Journals (Sweden)

    Sun Xiao

    2004-03-01

    Full Text Available Abstract Several studies of haplotype structures in the human genome in various populations have found that the human chromosomes are structured such that each chromosome can be divided into many blocks, within which there is limited haplotype diversity. In addition, only a few genetic markers in a putative block are needed to capture most of the diversity within a block. There has been no systematic empirical study of the effects of sample size and marker set on the identified block structures and representative marker sets, however. The purpose of this study was to conduct a detailed empirical study to examine such impacts. Towards this goal, we have analysed three representative autosomal regions from a large genome-wide study of haplotypes with samples consisting of African-Americans and samples consisting of Japanese and Chinese individuals. For both populations, we have found that the sample size and marker set have significant impact on the number of blocks and the total number of representative markers identified. The marker set in particular has very strong impacts, and our results indicate that the marker density in the original datasets may not be adequate to allow a meaningful characterisation of haplotype structures. In general, we conclude that we need a relatively large sample size and a very dense marker panel in the study of haplotype structures in human populations.

  16. Prediction of the filtrate particle size distribution from the pore size distribution in membrane filtration: Numerical correlations from computer simulations

    Science.gov (United States)

    Marrufo-Hernández, Norma Alejandra; Hernández-Guerrero, Maribel; Nápoles-Duarte, José Manuel; Palomares-Báez, Juan Pedro; Chávez-Rojo, Marco Antonio

    2018-03-01

    We present a computational model that describes the diffusion of a hard spheres colloidal fluid through a membrane. The membrane matrix is modeled as a series of flat parallel planes with circular pores of different sizes and random spatial distribution. This model was employed to determine how the size distribution of the colloidal filtrate depends on the size distributions of both, the particles in the feed and the pores of the membrane, as well as to describe the filtration kinetics. A Brownian dynamics simulation study considering normal distributions was developed in order to determine empirical correlations between the parameters that characterize these distributions. The model can also be extended to other distributions such as log-normal. This study could, therefore, facilitate the selection of membranes for industrial or scientific filtration processes once the size distribution of the feed is known and the expected characteristics in the filtrate have been defined.

  17. Optimal sampling strategy for data mining

    International Nuclear Information System (INIS)

    Ghaffar, A.; Shahbaz, M.; Mahmood, W.

    2013-01-01

    Latest technology like Internet, corporate intranets, data warehouses, ERP's, satellites, digital sensors, embedded systems, mobiles networks all are generating such a massive amount of data that it is getting very difficult to analyze and understand all these data, even using data mining tools. Huge datasets are becoming a difficult challenge for classification algorithms. With increasing amounts of data, data mining algorithms are getting slower and analysis is getting less interactive. Sampling can be a solution. Using a fraction of computing resources, Sampling can often provide same level of accuracy. The process of sampling requires much care because there are many factors involved in the determination of correct sample size. The approach proposed in this paper tries to find a solution to this problem. Based on a statistical formula, after setting some parameters, it returns a sample size called s ufficient sample size , which is then selected through probability sampling. Results indicate the usefulness of this technique in coping with the problem of huge datasets. (author)

  18. Crystallite size variation of TiO_2 samples depending time heat treatment

    International Nuclear Information System (INIS)

    Galante, A.G.M.; Paula, F.R. de; Montanhera, M.A.; Pereira, E.A.; Spada, E.R.

    2016-01-01

    Titanium dioxide (TiO_2) is an oxide semiconductor that may be found in mixed phase or in distinct phases: brookite, anatase and rutile. In this work was carried out the study of the residence time influence at a given temperature in the TiO_2 powder physical properties. After the powder synthesis, the samples were divided and heat treated at 650 °C with a ramp up to 3 °C/min and a residence time ranging from 0 to 20 hours and subsequently characterized by x-ray diffraction. Analyzing the obtained diffraction patterns, it was observed that, from 5-hour residence time, began the two-distinct phase coexistence: anatase and rutile. It also calculated the average crystallite size of each sample. The results showed an increase in average crystallite size with increasing residence time of the heat treatment. (author)

  19. The Influence of the Size, Age and Sex on the Computed Tomographic Measured Size of the Pituitary Gland in Normal Horses.

    Science.gov (United States)

    Crijns, C P; Van Bree, H J; Broeckx, B J G; Schauvliege, S; Van Loon, G; Martens, A; Vanderperren, K; Dingemanse, W B; Gielen, I M

    2017-06-01

    The objective of this study was to examine the influence of the size, age and sex of the horse on the size of the pituitary gland and determine the possibility of using the pituitary gland height-to-brain area ratio (P:B ratio) to allow comparison of different sized and aged horses. Thirty-two horses without pituitary pars inter-media dysfunction that underwent a contrast-enhanced computed tomographic (CT) examination were included in a cross-sectional study. On the CT images, the pituitary gland height was measured and the P:B ratio was calculated. These measurements were correlated to the size, age and sex of the horses. The pituitary gland height was significantly associated with the size (P horses. No significant association was found between the P:B ratio and the size (P = 0.25), the age (P = 0.06) or the sex (P = 0.25) of the horses. In conclusion, the pituitary gland size varies between different sized and aged horses. The use of the P:B ratio is a valuable metric for making comparisons between the pituitary glands of these horses. © 2017 Blackwell Verlag GmbH.

  20. How Sample Size Affects a Sampling Distribution

    Science.gov (United States)

    Mulekar, Madhuri S.; Siegel, Murray H.

    2009-01-01

    If students are to understand inferential statistics successfully, they must have a profound understanding of the nature of the sampling distribution. Specifically, they must comprehend the determination of the expected value and standard error of a sampling distribution as well as the meaning of the central limit theorem. Many students in a high…

  1. Sample Size Requirements for Assessing Statistical Moments of Simulated Crop Yield Distributions

    NARCIS (Netherlands)

    Lehmann, N.; Finger, R.; Klein, T.; Calanca, P.

    2013-01-01

    Mechanistic crop growth models are becoming increasingly important in agricultural research and are extensively used in climate change impact assessments. In such studies, statistics of crop yields are usually evaluated without the explicit consideration of sample size requirements. The purpose of

  2. PIXE–PIGE analysis of size-segregated aerosol samples from remote areas

    Energy Technology Data Exchange (ETDEWEB)

    Calzolai, G., E-mail: calzolai@fi.infn.it [Department of Physics and Astronomy, University of Florence and National Institute of Nuclear Physics (INFN), Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Chiari, M.; Lucarelli, F.; Nava, S.; Taccetti, F. [Department of Physics and Astronomy, University of Florence and National Institute of Nuclear Physics (INFN), Via G. Sansone 1, 50019 Sesto Fiorentino (Italy); Becagli, S.; Frosini, D.; Traversi, R.; Udisti, R. [Department of Chemistry, University of Florence, Via della Lastruccia 3, 50019 Sesto Fiorentino (Italy)

    2014-01-01

    The chemical characterization of size-segregated samples is helpful to study the aerosol effects on both human health and environment. The sampling with multi-stage cascade impactors (e.g., Small Deposit area Impactor, SDI) produces inhomogeneous samples, with a multi-spot geometry and a non-negligible particle stratification. At LABEC (Laboratory of nuclear techniques for the Environment and the Cultural Heritage), an external beam line is fully dedicated to PIXE–PIGE analysis of aerosol samples. PIGE is routinely used as a sidekick of PIXE to correct the underestimation of PIXE in quantifying the concentration of the lightest detectable elements, like Na or Al, due to X-ray absorption inside the individual aerosol particles. In this work PIGE has been used to study proper attenuation correction factors for SDI samples: relevant attenuation effects have been observed also for stages collecting smaller particles, and consequent implications on the retrieved aerosol modal structure have been evidenced.

  3. The one-sample PARAFAC approach reveals molecular size distributions of fluorescent components in dissolved organic matter

    DEFF Research Database (Denmark)

    Wünsch, Urban; Murphy, Kathleen R.; Stedmon, Colin

    2017-01-01

    Molecular size plays an important role in dissolved organic matter (DOM) biogeochemistry, but its relationship with the fluorescent fraction of DOM (FDOM) remains poorly resolved. Here high-performance size exclusion chromatography (HPSEC) was coupled to fluorescence emission-excitation (EEM...... but not their spectral properties. Thus, in contrast to absorption measurements, bulk fluorescence is unlikely to reliably indicate the average molecular size of DOM. The one-sample approach enables robust and independent cross-site comparisons without large-scale sampling efforts and introduces new analytical...... opportunities for elucidating the origins and biogeochemical properties of FDOM...

  4. Advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1983-01-01

    An improved computer controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high speed matrix printer, and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction, and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha, and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  5. 14CO2 analysis of soil gas: Evaluation of sample size limits and sampling devices

    Science.gov (United States)

    Wotte, Anja; Wischhöfer, Philipp; Wacker, Lukas; Rethemeyer, Janet

    2017-12-01

    Radiocarbon (14C) analysis of CO2 respired from soils or sediments is a valuable tool to identify different carbon sources. The collection and processing of the CO2, however, is challenging and prone to contamination. We thus continuously improve our handling procedures and present a refined method for the collection of even small amounts of CO2 in molecular sieve cartridges (MSCs) for accelerator mass spectrometry 14C analysis. Using a modified vacuum rig and an improved desorption procedure, we were able to increase the CO2 recovery from the MSC (95%) as well as the sample throughput compared to our previous study. By processing series of different sample size, we show that our MSCs can be used for CO2 samples of as small as 50 μg C. The contamination by exogenous carbon determined in these laboratory tests, was less than 2.0 μg C from fossil and less than 3.0 μg C from modern sources. Additionally, we tested two sampling devices for the collection of CO2 samples released from soils or sediments, including a respiration chamber and a depth sampler, which are connected to the MSC. We obtained a very promising, low process blank for the entire CO2 sampling and purification procedure of ∼0.004 F14C (equal to 44,000 yrs BP) and ∼0.003 F14C (equal to 47,000 yrs BP). In contrast to previous studies, we observed no isotopic fractionation towards lighter δ13C values during the passive sampling with the depth samplers.

  6. The attention-weighted sample-size model of visual short-term memory: Attention capture predicts resource allocation and memory load.

    Science.gov (United States)

    Smith, Philip L; Lilburn, Simon D; Corbett, Elaine A; Sewell, David K; Kyllingsbæk, Søren

    2016-09-01

    We investigated the capacity of visual short-term memory (VSTM) in a phase discrimination task that required judgments about the configural relations between pairs of black and white features. Sewell et al. (2014) previously showed that VSTM capacity in an orientation discrimination task was well described by a sample-size model, which views VSTM as a resource comprised of a finite number of noisy stimulus samples. The model predicts the invariance of [Formula: see text] , the sum of squared sensitivities across items, for displays of different sizes. For phase discrimination, the set-size effect significantly exceeded that predicted by the sample-size model for both simultaneously and sequentially presented stimuli. Instead, the set-size effect and the serial position curves with sequential presentation were predicted by an attention-weighted version of the sample-size model, which assumes that one of the items in the display captures attention and receives a disproportionate share of resources. The choice probabilities and response time distributions from the task were well described by a diffusion decision model in which the drift rates embodied the assumptions of the attention-weighted sample-size model. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Generalized sampling in Julia

    DEFF Research Database (Denmark)

    Jacobsen, Christian Robert Dahl; Nielsen, Morten; Rasmussen, Morten Grud

    2017-01-01

    Generalized sampling is a numerically stable framework for obtaining reconstructions of signals in different bases and frames from their samples. For example, one can use wavelet bases for reconstruction given frequency measurements. In this paper, we will introduce a carefully documented toolbox...... for performing generalized sampling in Julia. Julia is a new language for technical computing with focus on performance, which is ideally suited to handle the large size problems often encountered in generalized sampling. The toolbox provides specialized solutions for the setup of Fourier bases and wavelets....... The performance of the toolbox is compared to existing implementations of generalized sampling in MATLAB....

  8. Statistical characterization of a large geochemical database and effect of sample size

    Science.gov (United States)

    Zhang, C.; Manheim, F.T.; Hinde, J.; Grossman, J.N.

    2005-01-01

    smaller numbers of data points showed that few elements passed standard statistical tests for normality or log-normality until sample size decreased to a few hundred data points. Large sample size enhances the power of statistical tests, and leads to rejection of most statistical hypotheses for real data sets. For large sample sizes (e.g., n > 1000), graphical methods such as histogram, stem-and-leaf, and probability plots are recommended for rough judgement of probability distribution if needed. ?? 2005 Elsevier Ltd. All rights reserved.

  9. Fluctuations, Finite-Size Effects and the Thermodynamic Limit in Computer Simulations: Revisiting the Spatial Block Analysis Method

    Directory of Open Access Journals (Sweden)

    Maziar Heidari

    2018-03-01

    Full Text Available The spatial block analysis (SBA method has been introduced to efficiently extrapolate thermodynamic quantities from finite-size computer simulations of a large variety of physical systems. In the particular case of simple liquids and liquid mixtures, by subdividing the simulation box into blocks of increasing size and calculating volume-dependent fluctuations of the number of particles, it is possible to extrapolate the bulk isothermal compressibility and Kirkwood–Buff integrals in the thermodynamic limit. Only by explicitly including finite-size effects, ubiquitous in computer simulations, into the SBA method, the extrapolation to the thermodynamic limit can be achieved. In this review, we discuss two of these finite-size effects in the context of the SBA method due to (i the statistical ensemble and (ii the finite integration domains used in computer simulations. To illustrate the method, we consider prototypical liquids and liquid mixtures described by truncated and shifted Lennard–Jones (TSLJ potentials. Furthermore, we show some of the most recent developments of the SBA method, in particular its use to calculate chemical potentials of liquids in a wide range of density/concentration conditions.

  10. A note on power and sample size calculations for the Kruskal-Wallis test for ordered categorical data.

    Science.gov (United States)

    Fan, Chunpeng; Zhang, Donghui

    2012-01-01

    Although the Kruskal-Wallis test has been widely used to analyze ordered categorical data, power and sample size methods for this test have been investigated to a much lesser extent when the underlying multinomial distributions are unknown. This article generalizes the power and sample size procedures proposed by Fan et al. ( 2011 ) for continuous data to ordered categorical data, when estimates from a pilot study are used in the place of knowledge of the true underlying distribution. Simulations show that the proposed power and sample size formulas perform well. A myelin oligodendrocyte glycoprotein (MOG) induced experimental autoimmunce encephalomyelitis (EAE) mouse study is used to demonstrate the application of the methods.

  11. Gridsampler – A Simulation Tool to Determine the Required Sample Size for Repertory Grid Studies

    Directory of Open Access Journals (Sweden)

    Mark Heckmann

    2017-01-01

    Full Text Available The repertory grid is a psychological data collection technique that is used to elicit qualitative data in the form of attributes as well as quantitative ratings. A common approach for evaluating multiple repertory grid data is sorting the elicited bipolar attributes (so called constructs into mutually exclusive categories by means of content analysis. An important question when planning this type of study is determining the sample size needed to a discover all attribute categories relevant to the field and b yield a predefined minimal number of attributes per category. For most applied researchers who collect multiple repertory grid data, programming a numeric simulation to answer these questions is not feasible. The gridsampler software facilitates determining the required sample size by providing a GUI for conducting the necessary numerical simulations. Researchers can supply a set of parameters suitable for the specific research situation, determine the required sample size, and easily explore the effects of changes in the parameter set.

  12. Anomalies in the detection of change: When changes in sample size are mistaken for changes in proportions.

    Science.gov (United States)

    Fiedler, Klaus; Kareev, Yaakov; Avrahami, Judith; Beier, Susanne; Kutzner, Florian; Hütter, Mandy

    2016-01-01

    Detecting changes, in performance, sales, markets, risks, social relations, or public opinions, constitutes an important adaptive function. In a sequential paradigm devised to investigate detection of change, every trial provides a sample of binary outcomes (e.g., correct vs. incorrect student responses). Participants have to decide whether the proportion of a focal feature (e.g., correct responses) in the population from which the sample is drawn has decreased, remained constant, or increased. Strong and persistent anomalies in change detection arise when changes in proportional quantities vary orthogonally to changes in absolute sample size. Proportional increases are readily detected and nonchanges are erroneously perceived as increases when absolute sample size increases. Conversely, decreasing sample size facilitates the correct detection of proportional decreases and the erroneous perception of nonchanges as decreases. These anomalies are however confined to experienced samples of elementary raw events from which proportions have to be inferred inductively. They disappear when sample proportions are described as percentages in a normalized probability format. To explain these challenging findings, it is essential to understand the inductive-learning constraints imposed on decisions from experience.

  13. Unbiased tensor-based morphometry: Improved robustness and sample size estimates for Alzheimer’s disease clinical trials

    Science.gov (United States)

    Hua, Xue; Hibar, Derrek P.; Ching, Christopher R.K.; Boyle, Christina P.; Rajagopalan, Priya; Gutman, Boris A.; Leow, Alex D.; Toga, Arthur W.; Jack, Clifford R.; Harvey, Danielle; Weiner, Michael W.; Thompson, Paul M.

    2013-01-01

    Various neuroimaging measures are being evaluated for tracking Alzheimer’s disease (AD) progression in therapeutic trials, including measures of structural brain change based on repeated scanning of patients with magnetic resonance imaging (MRI). Methods to compute brain change must be robust to scan quality. Biases may arise if any scans are thrown out, as this can lead to the true changes being overestimated or underestimated. Here we analyzed the full MRI dataset from the first phase of Alzheimer’s Disease Neuroimaging Initiative (ADNI-1) from the first phase of Alzheimer’s Disease Neuroimaging Initiative (ADNI-1) and assessed several sources of bias that can arise when tracking brain changes with structural brain imaging methods, as part of a pipeline for tensor-based morphometry (TBM). In all healthy subjects who completed MRI scanning at screening, 6, 12, and 24 months, brain atrophy was essentially linear with no detectable bias in longitudinal measures. In power analyses for clinical trials based on these change measures, only 39 AD patients and 95 mild cognitive impairment (MCI) subjects were needed for a 24-month trial to detect a 25% reduction in the average rate of change using a two-sided test (α=0.05, power=80%). Further sample size reductions were achieved by stratifying the data into Apolipoprotein E (ApoE) ε4 carriers versus non-carriers. We show how selective data exclusion affects sample size estimates, motivating an objective comparison of different analysis techniques based on statistical power and robustness. TBM is an unbiased, robust, high-throughput imaging surrogate marker for large, multi-site neuroimaging studies and clinical trials of AD and MCI. PMID:23153970

  14. On sample size of the kruskal-wallis test with application to a mouse peritoneal cavity study.

    Science.gov (United States)

    Fan, Chunpeng; Zhang, Donghui; Zhang, Cun-Hui

    2011-03-01

    As the nonparametric generalization of the one-way analysis of variance model, the Kruskal-Wallis test applies when the goal is to test the difference between multiple samples and the underlying population distributions are nonnormal or unknown. Although the Kruskal-Wallis test has been widely used for data analysis, power and sample size methods for this test have been investigated to a much lesser extent. This article proposes new power and sample size calculation methods for the Kruskal-Wallis test based on the pilot study in either a completely nonparametric model or a semiparametric location model. No assumption is made on the shape of the underlying population distributions. Simulation results show that, in terms of sample size calculation for the Kruskal-Wallis test, the proposed methods are more reliable and preferable to some more traditional methods. A mouse peritoneal cavity study is used to demonstrate the application of the methods. © 2010, The International Biometric Society.

  15. The Effect of Plot Size on Some Pratylenchus Penetrans ...

    African Journals Online (AJOL)

    Pratylenchus penetrans counts obtained from a rose field, sampled sequentially by decreasing the plot sizes were computed to obtain the respective sample means, variance and k-value of the negative binomial distribution. Plots 21 m x 80 m, 3.6 m x 3.6 m and 0.6 m x 0.6 m were sampled for the nematode. It is reported ...

  16. Comparison of fluvial suspended-sediment concentrations and particle-size distributions measured with in-stream laser diffraction and in physical samples

    Science.gov (United States)

    Czuba, Jonathan A.; Straub, Timothy D.; Curran, Christopher A.; Landers, Mark N.; Domanski, Marian M.

    2015-01-01

    Laser-diffraction technology, recently adapted for in-stream measurement of fluvial suspended-sediment concentrations (SSCs) and particle-size distributions (PSDs), was tested with a streamlined (SL), isokinetic version of the Laser In-Situ Scattering and Transmissometry (LISST) for measuring volumetric SSCs and PSDs ranging from 1.8-415 µm in 32 log-spaced size classes. Measured SSCs and PSDs from the LISST-SL were compared to a suite of 22 datasets (262 samples in all) of concurrent suspended-sediment and streamflow measurements using a physical sampler and acoustic Doppler current profiler collected during 2010-12 at 16 U.S. Geological Survey streamflow-gaging stations in Illinois and Washington (basin areas: 38 – 69,264 km2). An unrealistically low computed effective density (mass SSC / volumetric SSC) of 1.24 g/ml (95% confidence interval: 1.05-1.45 g/ml) provided the best-fit value (R2 = 0.95; RMSE = 143 mg/L) for converting volumetric SSC to mass SSC for over 2 orders of magnitude of SSC (12-2,170 mg/L; covering a substantial range of SSC that can be measured by the LISST-SL) despite being substantially lower than the sediment particle density of 2.67 g/ml (range: 2.56-2.87 g/ml, 23 samples). The PSDs measured by the LISST-SL were in good agreement with those derived from physical samples over the LISST-SL's measureable size range. Technical and operational limitations of the LISST-SL are provided to facilitate the collection of more accurate data in the future. Additionally, the spatial and temporal variability of SSC and PSD measured by the LISST-SL is briefly described to motivate its potential for advancing our understanding of suspended-sediment transport by rivers.

  17. Atmospheric aerosol sampling campaign in Budapest and K-puszta. Part 1. Elemental concentrations and size distributions

    International Nuclear Information System (INIS)

    Dobos, E.; Borbely-Kiss, I.; Kertesz, Zs.; Szabo, Gy.; Salma, I.

    2004-01-01

    Complete text of publication follows. Atmospheric aerosol samples were collected in a sampling campaign from 24 July to 1 Au- gust, 2003 in Hungary. The sampling were performed in two places simultaneously: in Budapest (urban site) and K-puszta (remote area). Two PIXE International 7-stage cascade impactors were used for aerosol sampling with 24 hours duration. These impactors separate the aerosol into 7 size ranges. The elemental concentrations of the samples were obtained by proton-induced X-ray Emission (PIXE) analysis. Size distributions of S, Si, Ca, W, Zn, Pb and Fe elements were investigated in K-puszta and in Budapest. Average rates (shown in Table 1) of the elemental concentrations was calculated for each stage (in %) from the obtained distributions. The elements can be grouped into two parts on the basis of these data. The majority of the particle containing Fe, Si, Ca, (Ti) are in the 2-8 μm size range (first group). These soil origin elements were found usually in higher concentration in Budapest than in K-puszta (Fig.1.). The second group consisted of S, Pb and (W). The majority of these elements was found in the 0.25-1 μm size range and was much higher in Budapest than in K-puszta. W was measured only in samples collected in Budapest. Zn has uniform distribution in Budapest and does not belong to the above mentioned groups. This work was supported by the National Research and Development Program (NRDP 3/005/2001). (author)

  18. Size Distributions and Characterization of Native and Ground Samples for Toxicology Studies

    Science.gov (United States)

    McKay, David S.; Cooper, Bonnie L.; Taylor, Larry A.

    2010-01-01

    This slide presentation shows charts and graphs that review the particle size distribution and characterization of natural and ground samples for toxicology studies. There are graphs which show the volume distribution versus the number distribution for natural occurring dust, jet mill ground dust, and ball mill ground dust.

  19. Interval sampling methods and measurement error: a computer simulation.

    Science.gov (United States)

    Wirth, Oliver; Slaven, James; Taylor, Matthew A

    2014-01-01

    A simulation study was conducted to provide a more thorough account of measurement error associated with interval sampling methods. A computer program simulated the application of momentary time sampling, partial-interval recording, and whole-interval recording methods on target events randomly distributed across an observation period. The simulation yielded measures of error for multiple combinations of observation period, interval duration, event duration, and cumulative event duration. The simulations were conducted up to 100 times to yield measures of error variability. Although the present simulation confirmed some previously reported characteristics of interval sampling methods, it also revealed many new findings that pertain to each method's inherent strengths and weaknesses. The analysis and resulting error tables can help guide the selection of the most appropriate sampling method for observation-based behavioral assessments. © Society for the Experimental Analysis of Behavior.

  20. Influence of the Pixel Sizes of Reference Computed Tomography on Single-photon Emission Computed Tomography Image Reconstruction Using Conjugate-gradient Algorithm.

    Science.gov (United States)

    Okuda, Kyohei; Sakimoto, Shota; Fujii, Susumu; Ida, Tomonobu; Moriyama, Shigeru

    The frame-of-reference using computed-tomography (CT) coordinate system on single-photon emission computed tomography (SPECT) reconstruction is one of the advanced characteristics of the xSPECT reconstruction system. The aim of this study was to reveal the influence of the high-resolution frame-of-reference on the xSPECT reconstruction. 99m Tc line-source phantom and National Electrical Manufacturers Association (NEMA) image quality phantom were scanned using the SPECT/CT system. xSPECT reconstructions were performed with the reference CT images in different sizes of the display field-of-view (DFOV) and pixel. The pixel sizes of the reconstructed xSPECT images were close to 2.4 mm, which is acquired as originally projection data, even if the reference CT resolution was varied. The full width at half maximum (FWHM) of the line-source, absolute recovery coefficient, and background variability of image quality phantom were independent on the sizes of DFOV in the reference CT images. The results of this study revealed that the image quality of the reconstructed xSPECT images is not influenced by the resolution of frame-of-reference on SPECT reconstruction.

  1. Size Matters: Assessing Optimum Soil Sample Size for Fungal and Bacterial Community Structure Analyses Using High Throughput Sequencing of rRNA Gene Amplicons

    Directory of Open Access Journals (Sweden)

    Christopher Ryan Penton

    2016-06-01

    Full Text Available We examined the effect of different soil sample sizes obtained from an agricultural field, under a single cropping system uniform in soil properties and aboveground crop responses, on bacterial and fungal community structure and microbial diversity indices. DNA extracted from soil sample sizes of 0.25, 1, 5 and 10 g using MoBIO kits and from 10 and 100 g sizes using a bead-beating method (SARDI were used as templates for high-throughput sequencing of 16S and 28S rRNA gene amplicons for bacteria and fungi, respectively, on the Illumina MiSeq and Roche 454 platforms. Sample size significantly affected overall bacterial and fungal community structure, replicate dispersion and the number of operational taxonomic units (OTUs retrieved. Richness, evenness and diversity were also significantly affected. The largest diversity estimates were always associated with the 10 g MoBIO extractions with a corresponding reduction in replicate dispersion. For the fungal data, smaller MoBIO extractions identified more unclassified Eukaryota incertae sedis and unclassified glomeromycota while the SARDI method retrieved more abundant OTUs containing unclassified Pleosporales and the fungal genera Alternaria and Cercophora. Overall, these findings indicate that a 10 g soil DNA extraction is most suitable for both soil bacterial and fungal communities for retrieving optimal diversity while still capturing rarer taxa in concert with decreasing replicate variation.

  2. Evaluating sampling strategy for DNA barcoding study of coastal and inland halo-tolerant Poaceae and Chenopodiaceae: A case study for increased sample size.

    Directory of Open Access Journals (Sweden)

    Peng-Cheng Yao

    Full Text Available Environmental conditions in coastal salt marsh habitats have led to the development of specialist genetic adaptations. We evaluated six DNA barcode loci of the 53 species of Poaceae and 15 species of Chenopodiaceae from China's coastal salt marsh area and inland area. Our results indicate that the optimum DNA barcode was ITS for coastal salt-tolerant Poaceae and matK for the Chenopodiaceae. Sampling strategies for ten common species of Poaceae and Chenopodiaceae were analyzed according to optimum barcode. We found that by increasing the number of samples collected from the coastal salt marsh area on the basis of inland samples, the number of haplotypes of Arundinella hirta, Digitaria ciliaris, Eleusine indica, Imperata cylindrica, Setaria viridis, and Chenopodium glaucum increased, with a principal coordinate plot clearly showing increased distribution points. The results of a Mann-Whitney test showed that for Digitaria ciliaris, Eleusine indica, Imperata cylindrica, and Setaria viridis, the distribution of intraspecific genetic distances was significantly different when samples from the coastal salt marsh area were included (P < 0.01. These results suggest that increasing the sample size in specialist habitats can improve measurements of intraspecific genetic diversity, and will have a positive effect on the application of the DNA barcodes in widely distributed species. The results of random sampling showed that when sample size reached 11 for Chloris virgata, Chenopodium glaucum, and Dysphania ambrosioides, 13 for Setaria viridis, and 15 for Eleusine indica, Imperata cylindrica and Chenopodium album, average intraspecific distance tended to reach stability. These results indicate that the sample size for DNA barcode of globally distributed species should be increased to 11-15.

  3. Adaptive clinical trial designs with pre-specified rules for modifying the sample size: understanding efficient types of adaptation.

    Science.gov (United States)

    Levin, Gregory P; Emerson, Sarah C; Emerson, Scott S

    2013-04-15

    Adaptive clinical trial design has been proposed as a promising new approach that may improve the drug discovery process. Proponents of adaptive sample size re-estimation promote its ability to avoid 'up-front' commitment of resources, better address the complicated decisions faced by data monitoring committees, and minimize accrual to studies having delayed ascertainment of outcomes. We investigate aspects of adaptation rules, such as timing of the adaptation analysis and magnitude of sample size adjustment, that lead to greater or lesser statistical efficiency. Owing in part to the recent Food and Drug Administration guidance that promotes the use of pre-specified sampling plans, we evaluate alternative approaches in the context of well-defined, pre-specified adaptation. We quantify the relative costs and benefits of fixed sample, group sequential, and pre-specified adaptive designs with respect to standard operating characteristics such as type I error, maximal sample size, power, and expected sample size under a range of alternatives. Our results build on others' prior research by demonstrating in realistic settings that simple and easily implemented pre-specified adaptive designs provide only very small efficiency gains over group sequential designs with the same number of analyses. In addition, we describe optimal rules for modifying the sample size, providing efficient adaptation boundaries on a variety of scales for the interim test statistic for adaptation analyses occurring at several different stages of the trial. We thus provide insight into what are good and bad choices of adaptive sampling plans when the added flexibility of adaptive designs is desired. Copyright © 2012 John Wiley & Sons, Ltd.

  4. Determining Sample Size with a Given Range of Mean Effects in One-Way Heteroscedastic Analysis of Variance

    Science.gov (United States)

    Shieh, Gwowen; Jan, Show-Li

    2013-01-01

    The authors examined 2 approaches for determining the required sample size of Welch's test for detecting equality of means when the greatest difference between any 2 group means is given. It is shown that the actual power obtained with the sample size of the suggested approach is consistently at least as great as the nominal power. However, the…

  5. The use of gamma ray computed tomography to investigate soil compaction due to core sampling devices

    International Nuclear Information System (INIS)

    Pires, Luiz F.; Arthur, Robson C.J.; Correchel, Vladia; Bacchi, Osny O.S.; Reichardt, Klaus; Brasil, Rene P. Camponez do

    2004-01-01

    Compaction processes can influence soil physical properties such as soil density, porosity, pore size distribution, and processes like soil water and nutrient movements, root system distribution, and others. Soil porosity modification has important consequences like alterations in results of soil water retention curves. These alterations may cause differences in soil water storage calculations and matrix potential values, which are utilized in irrigation management systems. Because of this, soil-sampling techniques should avoid alterations of sample structure. In this work soil sample compaction caused by core sampling devices was investigated using the gamma ray computed tomography technique. A first generation tomograph with fixed source-detector arrangement and translation/rotational movements of the sample was utilized to obtain the images. The radioactive source is 241 Am, with an activity of 3.7 GBq, and the detector consists of a 3 in. x 3 in. NaI(Tl) scintillation crystal coupled to a photomultiplier tube. Soil samples were taken from an experimental field utilizing cylinders 4.0 cm high and 2.6 cm in diameter. Based on image analyses it was possible to detect compacted regions in all samples next to the cylinder wall due to the sampling system. Tomographic unit profiles of the sample permitted to identify higher values of soil density for deeper regions of the sample, and it was possible to determine the average densities and thickness of these layers. Tomographic analyses showed to be a very useful tool for soil compaction characterization and presented many advantages in relation to traditional methods. (author)

  6. Prediction of primary breast cancer size and T-stage using micro-computed tomography in lumpectomy specimens

    Directory of Open Access Journals (Sweden)

    Wafa M Sarraj

    2015-01-01

    Full Text Available Background: Histopathology is the only accepted method to measure and stage the breast tumor size. However, there is a need to find another method to measure and stage the tumor size when the pathological assessment is not available. Micro-computed tomography. (micro-CT has the ability to measure tumor in three dimensions in an intact lumpectomy specimen. In this study, we aimed to determine the accuracy of micro-CT to measure and stage the primary tumor size in breast lumpectomy specimens, as compared to the histopathology. Materials and Methods: Seventy-two women who underwent lumpectomy surgery at the Massachusetts General Hospital Department of Surgery from June 2011 to September 2011, and from August 2013 to December 2013 participated in this study. The lumpectomy specimens were scanned using micro-CT followed by routine pathological processing. The maximum dimension of the invasive breast tumor was obtained from the micro-CT image and was compared to the corresponding pathology report for each subject. Results: The invasive tumor size measurement by micro-CT was underestimated in 24. cases. (33%, overestimated in 37. cases. (51%, and matched it exactly in 11. cases. (15% compared to the histopathology measurement for all the cases. However, micro-CT T.stage classification differed from histopathology in only 11. (15.2% with 6. cases. (8.3% classified as a higher stage by micro-CT, and 5. cases. (6.9% classified as lower compared to histopathology. In addition, micro-CT demonstrated a statically significant strong agreement (κ =0.6, P < 0.05 with pathological tumor size and staging for invasive ductal carcinoma. (IDC group. In contrast, there was no agreement. (κ = .2, P = 0.67 between micro-CT and pathology in estimating and staging tumor size for invasive lobular carcinoma. (ILC group. This could be explained by a small sample size. (7 for ILC group. Conclusions: Micro-CT is a promising modality for measuring and staging the IDC.

  7. In Situ Sampling of Relative Dust Devil Particle Loads and Their Vertical Grain Size Distributions.

    Science.gov (United States)

    Raack, Jan; Reiss, Dennis; Balme, Matthew R; Taj-Eddine, Kamal; Ori, Gian Gabriele

    2017-04-19

    During a field campaign in the Sahara Desert in southern Morocco, spring 2012, we sampled the vertical grain size distribution of two active dust devils that exhibited different dimensions and intensities. With these in situ samples of grains in the vortices, it was possible to derive detailed vertical grain size distributions and measurements of the lifted relative particle load. Measurements of the two dust devils show that the majority of all lifted particles were only lifted within the first meter (∼46.5% and ∼61% of all particles; ∼76.5 wt % and ∼89 wt % of the relative particle load). Furthermore, ∼69% and ∼82% of all lifted sand grains occurred in the first meter of the dust devils, indicating the occurrence of "sand skirts." Both sampled dust devils were relatively small (∼15 m and ∼4-5 m in diameter) compared to dust devils in surrounding regions; nevertheless, measurements show that ∼58.5% to 73.5% of all lifted particles were small enough to go into suspension (grain size classification). This relatively high amount represents only ∼0.05 to 0.15 wt % of the lifted particle load. Larger dust devils probably entrain larger amounts of fine-grained material into the atmosphere, which can have an influence on the climate. Furthermore, our results indicate that the composition of the surface, on which the dust devils evolved, also had an influence on the particle load composition of the dust devil vortices. The internal particle load structure of both sampled dust devils was comparable related to their vertical grain size distribution and relative particle load, although both dust devils differed in their dimensions and intensities. A general trend of decreasing grain sizes with height was also detected. Key Words: Mars-Dust devils-Planetary science-Desert soils-Atmosphere-Grain sizes. Astrobiology 17, xxx-xxx.

  8. Computational Investigation of Effects of Grain Size on Ballistic Performance of Copper

    Science.gov (United States)

    He, Ge; Dou, Yangqing; Guo, Xiang; Liu, Yucheng

    2018-01-01

    Numerical simulations were conducted to compare ballistic performance and penetration mechanism of copper (Cu) with four representative grain sizes. Ballistic limit velocities for coarse-grained (CG) copper (grain size ≈ 90 µm), regular copper (grain size ≈ 30 µm), fine-grained (FG) copper (grain size ≈ 890 nm), and ultrafine-grained (UG) copper (grain size ≈ 200 nm) were determined for the first time through the simulations. It was found that the copper with reduced grain size would offer higher strength and better ductility, and therefore renders improved ballistic performance than the CG and regular copper. High speed impact and penetration behavior of the FG and UG copper was also compared with the CG coppers strengthened by nanotwinned (NT) regions. The comparison results showed the impact and penetration resistance of UG copper is comparable to the CG copper strengthened by NT regions with the minimum twin spacing. Therefore, besides the NT-strengthened copper, the single phase copper with nanoscale grain size could also be a strong candidate material for better ballistic protection. A computational modeling and simulation framework was proposed for this study, in which Johnson-Cook (JC) constitutive model is used to predict the plastic deformation of Cu; the JC damage model is to capture the penetration and fragmentation behavior of Cu; Bao-Wierzbicki (B-W) failure criterion defines the material's failure mechanisms; and temperature increase during this adiabatic penetration process is given by the Taylor-Quinney method.

  9. Toward a Singleton Undergraduate Computer Graphics Course in Small and Medium-Sized Colleges

    Science.gov (United States)

    Shesh, Amit

    2013-01-01

    This article discusses the evolution of a single undergraduate computer graphics course over five semesters, driven by a primary question: if one could offer only one undergraduate course in graphics, what would it include? This constraint is relevant to many small and medium-sized colleges that lack resources, adequate expertise, and enrollment…

  10. Basic distribution free identification tests for small size samples of environmental data

    International Nuclear Information System (INIS)

    Federico, A.G.; Musmeci, F.

    1998-01-01

    Testing two or more data sets for the hypothesis that they are sampled form the same population is often required in environmental data analysis. Typically the available samples have a small number of data and often then assumption of normal distributions is not realistic. On the other hand the diffusion of the days powerful Personal Computers opens new possible opportunities based on a massive use of the CPU resources. The paper reviews the problem introducing the feasibility of two non parametric approaches based on intrinsic equi probability properties of the data samples. The first one is based on a full re sampling while the second is based on a bootstrap approach. A easy to use program is presented. A case study is given based on the Chernobyl children contamination data [it

  11. Evaluating the performance of species richness estimators: sensitivity to sample grain size

    DEFF Research Database (Denmark)

    Hortal, Joaquín; Borges, Paulo A. V.; Gaspar, Clara

    2006-01-01

    and several recent estimators [proposed by Rosenzweig et al. (Conservation Biology, 2003, 17, 864-874), and Ugland et al. (Journal of Animal Ecology, 2003, 72, 888-897)] performed poorly. 3.  Estimations developed using the smaller grain sizes (pair of traps, traps, records and individuals) presented similar....... Data obtained with standardized sampling of 78 transects in natural forest remnants of five islands were aggregated in seven different grains (i.e. ways of defining a single sample): islands, natural areas, transects, pairs of traps, traps, database records and individuals to assess the effect of using...

  12. Considerations for Sample Preparation Using Size-Exclusion Chromatography for Home and Synchrotron Sources.

    Science.gov (United States)

    Rambo, Robert P

    2017-01-01

    The success of a SAXS experiment for structural investigations depends on two precise measurements, the sample and the buffer background. Buffer matching between the sample and background can be achieved using dialysis methods but in biological SAXS of monodisperse systems, sample preparation is routinely being performed with size exclusion chromatography (SEC). SEC is the most reliable method for SAXS sample preparation as the method not only purifies the sample for SAXS but also almost guarantees ideal buffer matching. Here, I will highlight the use of SEC for SAXS sample preparation and demonstrate using example proteins that SEC purification does not always provide for ideal samples. Scrutiny of the SEC elution peak using quasi-elastic and multi-angle light scattering techniques can reveal hidden features (heterogeneity) of the sample that should be considered during SAXS data analysis. In some cases, sample heterogeneity can be controlled using a small molecule additive and I outline a simple additive screening method for sample preparation.

  13. The study of the sample size on the transverse magnetoresistance of bismuth nanowires

    International Nuclear Information System (INIS)

    Zare, M.; Layeghnejad, R.; Sadeghi, E.

    2012-01-01

    The effects of sample size on the galvanomagnetice properties of semimetal nanowires are theoretically investigated. Transverse magnetoresistance (TMR) ratios have been calculated within a Boltzmann Transport Equation (BTE) approach by specular reflection approximation. Temperature and radius dependence of the transverse magnetoresistance of cylindrical Bismuth nanowires are given. The obtained values are in good agreement with the experimental results, reported by Heremans et al. - Highlights: ► In this study effects of sample size on the galvanomagnetic properties of Bi. ► Nanowires were explained by Parrott theorem by solving the Boltzmann Transport Equation. ► Transverse magnetoresistance (TMR) ratios have been measured by specular reflection approximation. ► Temperature and radius dependence of the transverse magnetoresistance of cylindrical Bismuth nanowires are given. ► The obtained values are in good agreement with the experimental results, reported by Heremans et al.

  14. Discrepancies in sample size calculations and data analyses reported in randomised trials: comparison of publications with protocols

    DEFF Research Database (Denmark)

    Chan, A.W.; Hrobjartsson, A.; Jorgensen, K.J.

    2008-01-01

    OBJECTIVE: To evaluate how often sample size calculations and methods of statistical analysis are pre-specified or changed in randomised trials. DESIGN: Retrospective cohort study. Data source Protocols and journal publications of published randomised parallel group trials initially approved...... in 1994-5 by the scientific-ethics committees for Copenhagen and Frederiksberg, Denmark (n=70). MAIN OUTCOME MEASURE: Proportion of protocols and publications that did not provide key information about sample size calculations and statistical methods; proportion of trials with discrepancies between...... of handling missing data was described in 16 protocols and 49 publications. 39/49 protocols and 42/43 publications reported the statistical test used to analyse primary outcome measures. Unacknowledged discrepancies between protocols and publications were found for sample size calculations (18/34 trials...

  15. The computer system for the express-analysis of the irradiation samples

    International Nuclear Information System (INIS)

    Vzorov, I.K.; Kalmykov, A.V.; Korenev, S.A.; Minashkin, V.F.; Sikolenko, V.V.

    1999-01-01

    The computer system for the express-analysis (SEA) of the irradiation samples is described. The system is working together with the pulse high current electrons and ions source. It allows us to correct irradiation regime in real time. The SEA system automatically measures volt-ampere and volt-farad characteristics, sample resistance by 'four-probe' method, sample capacitor parameters. Its parameters are: in the volt-ampere measuring regime - U max = 200 V, minimal voltage step U sh =0.05 V, voltage accuracy 0.25%; in the capacity measuring regime - capacity measurement diapason 0 - 1600 pF, working frequencies diapason 1 -150 kHz, capacity accuracy 0.5%, voltage shifting diapason 1 - 200 V, minimal step of voltage shifting U sh 0.05 V. The SEA management is performed by IBM/AT computer. The control and measuring apparatus was realized in CAMAC standard. The programmed set consists of the first display procedures, control, treatment and information exit. (author)

  16. A Web-based Simulator for Sample Size and Power Estimation in Animal Carcinogenicity Studies

    Directory of Open Access Journals (Sweden)

    Hojin Moon

    2002-12-01

    Full Text Available A Web-based statistical tool for sample size and power estimation in animal carcinogenicity studies is presented in this paper. It can be used to provide a design with sufficient power for detecting a dose-related trend in the occurrence of a tumor of interest when competing risks are present. The tumors of interest typically are occult tumors for which the time to tumor onset is not directly observable. It is applicable to rodent tumorigenicity assays that have either a single terminal sacrifice or multiple (interval sacrifices. The design is achieved by varying sample size per group, number of sacrifices, number of sacrificed animals at each interval, if any, and scheduled time points for sacrifice. Monte Carlo simulation is carried out in this tool to simulate experiments of rodent bioassays because no closed-form solution is available. It takes design parameters for sample size and power estimation as inputs through the World Wide Web. The core program is written in C and executed in the background. It communicates with the Web front end via a Component Object Model interface passing an Extensible Markup Language string. The proposed statistical tool is illustrated with an animal study in lung cancer prevention research.

  17. Generalized procedures for determining inspection sample sizes (related to quantitative measurements). Vol. 1: Detailed explanations

    International Nuclear Information System (INIS)

    Jaech, J.L.; Lemaire, R.J.

    1986-11-01

    Generalized procedures have been developed to determine sample sizes in connection with the planning of inspection activities. These procedures are based on different measurement methods. They are applied mainly to Bulk Handling Facilities and Physical Inventory Verifications. The present report attempts (i) to assign to appropriate statistical testers (viz. testers for gross, partial and small defects) the measurement methods to be used, and (ii) to associate the measurement uncertainties with the sample sizes required for verification. Working papers are also provided to assist in the application of the procedures. This volume contains the detailed explanations concerning the above mentioned procedures

  18. (I Can't Get No) Saturation: A simulation and guidelines for sample sizes in qualitative research.

    Science.gov (United States)

    van Rijnsoever, Frank J

    2017-01-01

    I explore the sample size in qualitative research that is required to reach theoretical saturation. I conceptualize a population as consisting of sub-populations that contain different types of information sources that hold a number of codes. Theoretical saturation is reached after all the codes in the population have been observed once in the sample. I delineate three different scenarios to sample information sources: "random chance," which is based on probability sampling, "minimal information," which yields at least one new code per sampling step, and "maximum information," which yields the largest number of new codes per sampling step. Next, I use simulations to assess the minimum sample size for each scenario for systematically varying hypothetical populations. I show that theoretical saturation is more dependent on the mean probability of observing codes than on the number of codes in a population. Moreover, the minimal and maximal information scenarios are significantly more efficient than random chance, but yield fewer repetitions per code to validate the findings. I formulate guidelines for purposive sampling and recommend that researchers follow a minimum information scenario.

  19. Determination of a representative volume element based on the variability of mechanical properties with sample size in bread.

    Science.gov (United States)

    Ramírez, Cristian; Young, Ashley; James, Bryony; Aguilera, José M

    2010-10-01

    Quantitative analysis of food structure is commonly obtained by image analysis of a small portion of the material that may not be the representative of the whole sample. In order to quantify structural parameters (air cells) of 2 types of bread (bread and bagel) the concept of representative volume element (RVE) was employed. The RVE for bread, bagel, and gelatin-gel (used as control) was obtained from the relationship between sample size and the coefficient of variation, calculated from the apparent Young's modulus measured on 25 replicates. The RVE was obtained when the coefficient of variation for different sample sizes converged to a constant value. In the 2 types of bread tested, the tendency of the coefficient of variation was to decrease as the sample size increased, while in the homogeneous gelatin-gel, it remained always constant around 2.3% to 2.4%. The RVE resulted to be cubes with sides of 45 mm for bread, 20 mm for bagels, and 10 mm for gelatin-gel (smallest sample tested). The quantitative image analysis as well as visual observation demonstrated that bread presented the largest dispersion of air-cell sizes. Moreover, both the ratio of maximum air-cell area/image area and maximum air-cell height/image height were greater for bread (values of 0.05 and 0.30, respectively) than for bagels (0.03 and 0.20, respectively). Therefore, the size and the size variation of air cells present in the structure determined the size of the RVE. It was concluded that RVE is highly dependent on the heterogeneity of the structure of the types of baked products.

  20. Analysis of femtogram-sized plutonium samples by thermal ionization mass spectrometry

    International Nuclear Information System (INIS)

    Smith, D.H.; Duckworth, D.C.; Bostick, D.T.; Coleman, R.M.; McPherson, R.L.; McKown, H.S.

    1994-01-01

    The goal of this investigation was to extend the ability to perform isotopic analysis of plutonium to samples as small as possible. Plutonium ionizes thermally with quite good efficiency (first ionization potential 5.7 eV). Sub-nanogram sized samples can be analyzed on a near-routine basis given the necessary instrumentation. Efforts in this laboratory have been directed at rhenium-carbon systems; solutions of carbon in rhenium provide surfaces with work functions higher than pure rhenium (5.8 vs. ∼ 5.4 eV). Using a single resin bead as a sample loading medium both concentrates the sample nearly to a point and, due to its interaction with rhenium, produces the desired composite surface. Earlier work in this area showed that a layer of rhenium powder slurried in solution containing carbon substantially enhanced precision of isotopic measurements for uranium. Isotopic fractionation was virtually eliminated, and ionization efficiencies 2-5 times better than previously measured were attained for both Pu and U (1.7 and 0.5%, respectively). The other side of this coin should be the ability to analyze smaller samples, which is the subject of this report

  1. Sample Size and Robustness of Inferences from Logistic Regression in the Presence of Nonlinearity and Multicollinearity

    OpenAIRE

    Bergtold, Jason S.; Yeager, Elizabeth A.; Featherstone, Allen M.

    2011-01-01

    The logistic regression models has been widely used in the social and natural sciences and results from studies using this model can have significant impact. Thus, confidence in the reliability of inferences drawn from these models is essential. The robustness of such inferences is dependent on sample size. The purpose of this study is to examine the impact of sample size on the mean estimated bias and efficiency of parameter estimation and inference for the logistic regression model. A numbe...

  2. Bias in segmented gamma scans arising from size differences between calibration standards and assay samples

    International Nuclear Information System (INIS)

    Sampson, T.E.

    1991-01-01

    Recent advances in segmented gamma scanning have emphasized software corrections for gamma-ray self-adsorption in particulates or lumps of special nuclear material in the sample. another feature of this software is an attenuation correction factor formalism that explicitly accounts for differences in sample container size and composition between the calibration standards and the individual items being measured. Software without this container-size correction produces biases when the unknowns are not packaged in the same containers as the calibration standards. This new software allows the use of different size and composition containers for standards and unknowns, as enormous savings considering the expense of multiple calibration standard sets otherwise needed. This paper presents calculations of the bias resulting from not using this new formalism. These calculations may be used to estimate bias corrections for segmented gamma scanners that do not incorporate these advanced concepts

  3. Rule-of-thumb adjustment of sample sizes to accommodate dropouts in a two-stage analysis of repeated measurements.

    Science.gov (United States)

    Overall, John E; Tonidandel, Scott; Starbuck, Robert R

    2006-01-01

    Recent contributions to the statistical literature have provided elegant model-based solutions to the problem of estimating sample sizes for testing the significance of differences in mean rates of change across repeated measures in controlled longitudinal studies with differentially correlated error and missing data due to dropouts. However, the mathematical complexity and model specificity of these solutions make them generally inaccessible to most applied researchers who actually design and undertake treatment evaluation research in psychiatry. In contrast, this article relies on a simple two-stage analysis in which dropout-weighted slope coefficients fitted to the available repeated measurements for each subject separately serve as the dependent variable for a familiar ANCOVA test of significance for differences in mean rates of change. This article is about how a sample of size that is estimated or calculated to provide desired power for testing that hypothesis without considering dropouts can be adjusted appropriately to take dropouts into account. Empirical results support the conclusion that, whatever reasonable level of power would be provided by a given sample size in the absence of dropouts, essentially the same power can be realized in the presence of dropouts simply by adding to the original dropout-free sample size the number of subjects who would be expected to drop from a sample of that original size under conditions of the proposed study.

  4. Computational and experimental study of the cluster size distribution in MAPLE

    International Nuclear Information System (INIS)

    Leveugle, Elodie; Zhigilei, Leonid V.; Sellinger, Aaron; Fitz-Gerald, James M.

    2007-01-01

    A combined experimental and computational study is performed to investigate the origin and characteristics of the surface features observed in SEM images of thin polymer films deposited in matrix-assisted pulsed laser evaporation (MAPLE). Analysis of high-resolution SEM images of surface morphologies of the films deposited at different fluences reveals that the mass distributions of the surface features can be well described by a power-law, Y(N) ∝ N -t , with exponent -t ∼ -1.6. Molecular dynamic simulations of the MAPLE process predict a similar size distribution for large clusters observed in the ablation plume. A weak dependence of the cluster size distributions on fluence and target composition suggests that the power-law cluster size distribution may be a general characteristic of the ablation plume generated as a result of an explosive decomposition of a target region overheated above the limit of its thermodynamic stability. Based on the simulation results, we suggest that the ejection of large matrix-polymer clusters, followed by evaporation of the volatile matrix, is responsible for the formation of the surface features observed in the polymer films deposited in MAPLE experiments

  5. GENESIS 1.1: A hybrid-parallel molecular dynamics simulator with enhanced sampling algorithms on multiple computational platforms.

    Science.gov (United States)

    Kobayashi, Chigusa; Jung, Jaewoon; Matsunaga, Yasuhiro; Mori, Takaharu; Ando, Tadashi; Tamura, Koichi; Kamiya, Motoshi; Sugita, Yuji

    2017-09-30

    GENeralized-Ensemble SImulation System (GENESIS) is a software package for molecular dynamics (MD) simulation of biological systems. It is designed to extend limitations in system size and accessible time scale by adopting highly parallelized schemes and enhanced conformational sampling algorithms. In this new version, GENESIS 1.1, new functions and advanced algorithms have been added. The all-atom and coarse-grained potential energy functions used in AMBER and GROMACS packages now become available in addition to CHARMM energy functions. The performance of MD simulations has been greatly improved by further optimization, multiple time-step integration, and hybrid (CPU + GPU) computing. The string method and replica-exchange umbrella sampling with flexible collective variable choice are used for finding the minimum free-energy pathway and obtaining free-energy profiles for conformational changes of a macromolecule. These new features increase the usefulness and power of GENESIS for modeling and simulation in biological research. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  6. Uncertainty budget in internal monostandard NAA for small and large size samples analysis

    International Nuclear Information System (INIS)

    Dasari, K.B.; Acharya, R.

    2014-01-01

    Total uncertainty budget evaluation on determined concentration value is important under quality assurance programme. Concentration calculation in NAA or carried out by relative NAA and k0 based internal monostandard NAA (IM-NAA) method. IM-NAA method has been used for small and large sample analysis of clay potteries. An attempt was made to identify the uncertainty components in IM-NAA and uncertainty budget for La in both small and large size samples has been evaluated and compared. (author)

  7. Basic distribution free identification tests for small size samples of environmental data

    Energy Technology Data Exchange (ETDEWEB)

    Federico, A.G.; Musmeci, F. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Ambiente

    1998-01-01

    Testing two or more data sets for the hypothesis that they are sampled form the same population is often required in environmental data analysis. Typically the available samples have a small number of data and often then assumption of normal distributions is not realistic. On the other hand the diffusion of the days powerful Personal Computers opens new possible opportunities based on a massive use of the CPU resources. The paper reviews the problem introducing the feasibility of two non parametric approaches based on intrinsic equi probability properties of the data samples. The first one is based on a full re sampling while the second is based on a bootstrap approach. A easy to use program is presented. A case study is given based on the Chernobyl children contamination data. [Italiano] Nell`analisi di dati ambientali ricorre spesso il caso di dover sottoporre a test l`ipotesi di provenienza di due, o piu`, insiemi di dati dalla stessa popolazione. Tipicamente i dati disponibili sono pochi e spesso l`ipotesi di provenienza da distribuzioni normali non e` sostenibile. D`altra aprte la diffusione odierna di Personal Computer fornisce nuove possibili soluzioni basate sull`uso intensivo delle risorse della CPU. Il rapporto analizza il problema e presenta la possibilita` di utilizzo di due test non parametrici basati sulle proprieta` intrinseche di equiprobabilita` dei campioni. Il primo e` basato su una tecnica di ricampionamento esaustivo mentre il secondo su un approccio di tipo bootstrap. E` presentato un programma di semplice utilizzo e un caso di studio basato su dati di contaminazione di bambini a Chernobyl.

  8. A contemporary decennial global Landsat sample of changing agricultural field sizes

    Science.gov (United States)

    White, Emma; Roy, David

    2014-05-01

    Agriculture has caused significant human induced Land Cover Land Use (LCLU) change, with dramatic cropland expansion in the last century and significant increases in productivity over the past few decades. Satellite data have been used for agricultural applications including cropland distribution mapping, crop condition monitoring, crop production assessment and yield prediction. Satellite based agricultural applications are less reliable when the sensor spatial resolution is small relative to the field size. However, to date, studies of agricultural field size distributions and their change have been limited, even though this information is needed to inform the design of agricultural satellite monitoring systems. Moreover, the size of agricultural fields is a fundamental description of rural landscapes and provides an insight into the drivers of rural LCLU change. In many parts of the world field sizes may have increased. Increasing field sizes cause a subsequent decrease in the number of fields and therefore decreased landscape spatial complexity with impacts on biodiversity, habitat, soil erosion, plant-pollinator interactions, and impacts on the diffusion of herbicides, pesticides, disease pathogens, and pests. The Landsat series of satellites provide the longest record of global land observations, with 30m observations available since 1982. Landsat data are used to examine contemporary field size changes in a period (1980 to 2010) when significant global agricultural changes have occurred. A multi-scale sampling approach is used to locate global hotspots of field size change by examination of a recent global agricultural yield map and literature review. Nine hotspots are selected where significant field size change is apparent and where change has been driven by technological advancements (Argentina and U.S.), abrupt societal changes (Albania and Zimbabwe), government land use and agricultural policy changes (China, Malaysia, Brazil), and/or constrained by

  9. Computational analysis of the atomic size effect in bulk metallic glasses and their liquid precursors

    International Nuclear Information System (INIS)

    Kokotin, V.; Hermann, H.

    2008-01-01

    The atomic size effect and its consequences for the ability of multicomponent liquid alloys to form bulk metallic glasses are analyzed in terms of the generalized Bernal's model for liquids, following the hypothesis that maximum density in the liquid state improves the glass-forming ability. The maximum density that can be achieved in the liquid state is studied in the 2(N-1) dimensional parameter space of N-component systems. Computer simulations reveal that the size ratio of largest to smallest atoms are most relevant for achieving the maximum packing for N = 3-5, whereas the number of components plays a minor role. At small size ratio, the maximum packing density can be achieved by different atomic size distributions, whereas for medium size ratios the maximum density is always correlated to a concave size distribution. The relationship of the results to Miracle's efficient cluster packing model is also discussed

  10. Addressing small sample size bias in multiple-biomarker trials: Inclusion of biomarker-negative patients and Firth correction.

    Science.gov (United States)

    Habermehl, Christina; Benner, Axel; Kopp-Schneider, Annette

    2018-03-01

    In recent years, numerous approaches for biomarker-based clinical trials have been developed. One of these developments are multiple-biomarker trials, which aim to investigate multiple biomarkers simultaneously in independent subtrials. For low-prevalence biomarkers, small sample sizes within the subtrials have to be expected, as well as many biomarker-negative patients at the screening stage. The small sample sizes may make it unfeasible to analyze the subtrials individually. This imposes the need to develop new approaches for the analysis of such trials. With an expected large group of biomarker-negative patients, it seems reasonable to explore options to benefit from including them in such trials. We consider advantages and disadvantages of the inclusion of biomarker-negative patients in a multiple-biomarker trial with a survival endpoint. We discuss design options that include biomarker-negative patients in the study and address the issue of small sample size bias in such trials. We carry out a simulation study for a design where biomarker-negative patients are kept in the study and are treated with standard of care. We compare three different analysis approaches based on the Cox model to examine if the inclusion of biomarker-negative patients can provide a benefit with respect to bias and variance of the treatment effect estimates. We apply the Firth correction to reduce the small sample size bias. The results of the simulation study suggest that for small sample situations, the Firth correction should be applied to adjust for the small sample size bias. Additional to the Firth penalty, the inclusion of biomarker-negative patients in the analysis can lead to further but small improvements in bias and standard deviation of the estimates. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. An advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1984-01-01

    An improved computer-controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high-speed matrix printer and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  12. Computing power and sample size for case-control association studies with copy number polymorphism: application of mixture-based likelihood ratio test.

    Directory of Open Access Journals (Sweden)

    Wonkuk Kim

    Full Text Available Recent studies suggest that copy number polymorphisms (CNPs may play an important role in disease susceptibility and onset. Currently, the detection of CNPs mainly depends on microarray technology. For case-control studies, conventionally, subjects are assigned to a specific CNP category based on the continuous quantitative measure produced by microarray experiments, and cases and controls are then compared using a chi-square test of independence. The purpose of this work is to specify the likelihood ratio test statistic (LRTS for case-control sampling design based on the underlying continuous quantitative measurement, and to assess its power and relative efficiency (as compared to the chi-square test of independence on CNP counts. The sample size and power formulas of both methods are given. For the latter, the CNPs are classified using the Bayesian classification rule. The LRTS is more powerful than this chi-square test for the alternatives considered, especially alternatives in which the at-risk CNP categories have low frequencies. An example of the application of the LRTS is given for a comparison of CNP distributions in individuals of Caucasian or Taiwanese ethnicity, where the LRTS appears to be more powerful than the chi-square test, possibly due to misclassification of the most common CNP category into a less common category.

  13. Computer-controlled sampling system for airborne particulates

    International Nuclear Information System (INIS)

    Hall, C.F.; Anspaugh, L.R.; Koval, J.S.; Phelps, P.L.; Steinhaus, R.J.

    1975-01-01

    A self-contained, mobile, computer-controlled air-sampling system has been designed and fabricated that also collects and records the data from eight meteorological sensors. The air-samplers are activated automatically when the collected meteorological data meet the criteria specified at the beginning of the data-collection run. The filters from the samplers are intended to collect airborne 239 Pu for later radionuclide analysis and correlation with the meteorological data for the study of resuspended airborne radioactivity and for the development of a predictive model. This paper describes the system hardware, discusses the system and software concepts, and outlines the operational procedures for the system

  14. Power and sample-size estimation for microbiome studies using pairwise distances and PERMANOVA.

    Science.gov (United States)

    Kelly, Brendan J; Gross, Robert; Bittinger, Kyle; Sherrill-Mix, Scott; Lewis, James D; Collman, Ronald G; Bushman, Frederic D; Li, Hongzhe

    2015-08-01

    The variation in community composition between microbiome samples, termed beta diversity, can be measured by pairwise distance based on either presence-absence or quantitative species abundance data. PERMANOVA, a permutation-based extension of multivariate analysis of variance to a matrix of pairwise distances, partitions within-group and between-group distances to permit assessment of the effect of an exposure or intervention (grouping factor) upon the sampled microbiome. Within-group distance and exposure/intervention effect size must be accurately modeled to estimate statistical power for a microbiome study that will be analyzed with pairwise distances and PERMANOVA. We present a framework for PERMANOVA power estimation tailored to marker-gene microbiome studies that will be analyzed by pairwise distances, which includes: (i) a novel method for distance matrix simulation that permits modeling of within-group pairwise distances according to pre-specified population parameters; (ii) a method to incorporate effects of different sizes within the simulated distance matrix; (iii) a simulation-based method for estimating PERMANOVA power from simulated distance matrices; and (iv) an R statistical software package that implements the above. Matrices of pairwise distances can be efficiently simulated to satisfy the triangle inequality and incorporate group-level effects, which are quantified by the adjusted coefficient of determination, omega-squared (ω2). From simulated distance matrices, available PERMANOVA power or necessary sample size can be estimated for a planned microbiome study. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  15. The quantitative LOD score: test statistic and sample size for exclusion and linkage of quantitative traits in human sibships.

    Science.gov (United States)

    Page, G P; Amos, C I; Boerwinkle, E

    1998-04-01

    We present a test statistic, the quantitative LOD (QLOD) score, for the testing of both linkage and exclusion of quantitative-trait loci in randomly selected human sibships. As with the traditional LOD score, the boundary values of 3, for linkage, and -2, for exclusion, can be used for the QLOD score. We investigated the sample sizes required for inferring exclusion and linkage, for various combinations of linked genetic variance, total heritability, recombination distance, and sibship size, using fixed-size sampling. The sample sizes required for both linkage and exclusion were not qualitatively different and depended on the percentage of variance being linked or excluded and on the total genetic variance. Information regarding linkage and exclusion in sibships larger than size 2 increased as approximately all possible pairs n(n-1)/2 up to sibships of size 6. Increasing the recombination (theta) distance between the marker and the trait loci reduced empirically the power for both linkage and exclusion, as a function of approximately (1-2theta)4.

  16. The importance of plot size and the number of sampling seasons on capturing macrofungal species richness.

    Science.gov (United States)

    Li, Huili; Ostermann, Anne; Karunarathna, Samantha C; Xu, Jianchu; Hyde, Kevin D; Mortimer, Peter E

    2018-07-01

    The species-area relationship is an important factor in the study of species diversity, conservation biology, and landscape ecology. A deeper understanding of this relationship is necessary, in order to provide recommendations on how to improve the quality of data collection on macrofungal diversity in different land use systems in future studies, a systematic assessment of methodological parameters, in particular optimal plot sizes. The species-area relationship of macrofungi in tropical and temperate climatic zones and four different land use systems were investigated by determining the macrofungal species richness in plot sizes ranging from 100 m 2 to 10 000 m 2 over two sampling seasons. We found that the effect of plot size on recorded species richness significantly differed between land use systems with the exception of monoculture systems. For both climate zones, land use system needs to be considered when determining optimal plot size. Using an optimal plot size was more important than temporal replication (over two sampling seasons) in accurately recording species richness. Copyright © 2018 British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  17. Re-estimating sample size in cluster randomized trials with active recruitment within clusters

    NARCIS (Netherlands)

    van Schie, Sander; Moerbeek, Mirjam

    2014-01-01

    Often only a limited number of clusters can be obtained in cluster randomised trials, although many potential participants can be recruited within each cluster. Thus, active recruitment is feasible within the clusters. To obtain an efficient sample size in a cluster randomised trial, the cluster

  18. A simple approach to power and sample size calculations in logistic regression and Cox regression models.

    Science.gov (United States)

    Vaeth, Michael; Skovlund, Eva

    2004-06-15

    For a given regression problem it is possible to identify a suitably defined equivalent two-sample problem such that the power or sample size obtained for the two-sample problem also applies to the regression problem. For a standard linear regression model the equivalent two-sample problem is easily identified, but for generalized linear models and for Cox regression models the situation is more complicated. An approximately equivalent two-sample problem may, however, also be identified here. In particular, we show that for logistic regression and Cox regression models the equivalent two-sample problem is obtained by selecting two equally sized samples for which the parameters differ by a value equal to the slope times twice the standard deviation of the independent variable and further requiring that the overall expected number of events is unchanged. In a simulation study we examine the validity of this approach to power calculations in logistic regression and Cox regression models. Several different covariate distributions are considered for selected values of the overall response probability and a range of alternatives. For the Cox regression model we consider both constant and non-constant hazard rates. The results show that in general the approach is remarkably accurate even in relatively small samples. Some discrepancies are, however, found in small samples with few events and a highly skewed covariate distribution. Comparison with results based on alternative methods for logistic regression models with a single continuous covariate indicates that the proposed method is at least as good as its competitors. The method is easy to implement and therefore provides a simple way to extend the range of problems that can be covered by the usual formulas for power and sample size determination. Copyright 2004 John Wiley & Sons, Ltd.

  19. (I Can’t Get No) Saturation: A simulation and guidelines for sample sizes in qualitative research

    Science.gov (United States)

    2017-01-01

    I explore the sample size in qualitative research that is required to reach theoretical saturation. I conceptualize a population as consisting of sub-populations that contain different types of information sources that hold a number of codes. Theoretical saturation is reached after all the codes in the population have been observed once in the sample. I delineate three different scenarios to sample information sources: “random chance,” which is based on probability sampling, “minimal information,” which yields at least one new code per sampling step, and “maximum information,” which yields the largest number of new codes per sampling step. Next, I use simulations to assess the minimum sample size for each scenario for systematically varying hypothetical populations. I show that theoretical saturation is more dependent on the mean probability of observing codes than on the number of codes in a population. Moreover, the minimal and maximal information scenarios are significantly more efficient than random chance, but yield fewer repetitions per code to validate the findings. I formulate guidelines for purposive sampling and recommend that researchers follow a minimum information scenario. PMID:28746358

  20. Validation Of Intermediate Large Sample Analysis (With Sizes Up to 100 G) and Associated Facility Improvement

    International Nuclear Information System (INIS)

    Bode, P.; Koster-Ammerlaan, M.J.J.

    2018-01-01

    Pragmatic rather than physical correction factors for neutron and gamma-ray shielding were studied for samples of intermediate size, i.e. up to the 10-100 gram range. It was found that for most biological and geological materials, the neutron self-shielding is less than 5 % and the gamma-ray self-attenuation can easily be estimated. A trueness control material of 1 kg size was made based on use of left-overs of materials, used in laboratory intercomparisons. A design study for a large sample pool-side facility, handling plate-type volumes, had to be stopped because of a reduction in human resources, available for this CRP. The large sample NAA facilities were made available to guest scientists from Greece and Brazil. The laboratory for neutron activation analysis participated in the world’s first laboratory intercomparison utilizing large samples. (author)

  1. Effect of dislocation pile-up on size-dependent yield strength in finite single-crystal micro-samples

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Bo; Shibutani, Yoji, E-mail: sibutani@mech.eng.osaka-u.ac.jp [Department of Mechanical Engineering, Osaka University, Suita 565-0871 (Japan); Zhang, Xu [State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi' an Jiaotong University, Xi' an 710049 (China); School of Mechanics and Engineering Science, Zhengzhou University, Zhengzhou 450001 (China); Shang, Fulin [State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi' an Jiaotong University, Xi' an 710049 (China)

    2015-07-07

    Recent research has explained that the steeply increasing yield strength in metals depends on decreasing sample size. In this work, we derive a statistical physical model of the yield strength of finite single-crystal micro-pillars that depends on single-ended dislocation pile-up inside the micro-pillars. We show that this size effect can be explained almost completely by considering the stochastic lengths of the dislocation source and the dislocation pile-up length in the single-crystal micro-pillars. The Hall–Petch-type relation holds even in a microscale single-crystal, which is characterized by its dislocation source lengths. Our quantitative conclusions suggest that the number of dislocation sources and pile-ups are significant factors for the size effect. They also indicate that starvation of dislocation sources is another reason for the size effect. Moreover, we investigated the explicit relationship between the stacking fault energy and the dislocation “pile-up” effect inside the sample: materials with low stacking fault energy exhibit an obvious dislocation pile-up effect. Our proposed physical model predicts a sample strength that agrees well with experimental data, and our model can give a more precise prediction than the current single arm source model, especially for materials with low stacking fault energy.

  2. Modified energy-deposition model, for the computation of the stopping-power ratio for small cavity sizes

    International Nuclear Information System (INIS)

    Janssens, A.C.A.

    1981-01-01

    This paper presents a modification to the Spencer-Attix theory, which allows application of the theory to larger cavity sizes. The modified theory is in better agreement with the actual process of energy deposition by delta rays. In the first part of the paper it is recalled how the Spencer-Attix theory can be derived from basic principles, which allows a physical interpretation of the theory in terms of a function describing the space and direction average of the deposited energy. A realistic model for the computation of this function is described and the resulting expression for the stopping-power ratio is calculated. For the comparison between the Spencer-Attix theory and this modified expression a correction factor to the ''Bragg-Gray inhomogeneous term'' has been defined. This factor has been computed as a function of cavity size for different source energies and mean excitation energies; thus, general properties of this factor have been elucidated. The computations have been extended to include the density effect. It has been shown that the computation of the inhomogeneous term can be performed for any expression describing the energy loss per unit distance of the electrons as a function of their energy. Thus an expression has been calculated which is in agreement with a quadratic range-energy relationship. In conclusion, the concrete procedure for computing the stopping-power ratio is reviewed

  3. Neural dynamics as sampling: a model for stochastic computation in recurrent networks of spiking neurons.

    Science.gov (United States)

    Buesing, Lars; Bill, Johannes; Nessler, Bernhard; Maass, Wolfgang

    2011-11-01

    The organization of computations in networks of spiking neurons in the brain is still largely unknown, in particular in view of the inherently stochastic features of their firing activity and the experimentally observed trial-to-trial variability of neural systems in the brain. In principle there exists a powerful computational framework for stochastic computations, probabilistic inference by sampling, which can explain a large number of macroscopic experimental data in neuroscience and cognitive science. But it has turned out to be surprisingly difficult to create a link between these abstract models for stochastic computations and more detailed models of the dynamics of networks of spiking neurons. Here we create such a link and show that under some conditions the stochastic firing activity of networks of spiking neurons can be interpreted as probabilistic inference via Markov chain Monte Carlo (MCMC) sampling. Since common methods for MCMC sampling in distributed systems, such as Gibbs sampling, are inconsistent with the dynamics of spiking neurons, we introduce a different approach based on non-reversible Markov chains that is able to reflect inherent temporal processes of spiking neuronal activity through a suitable choice of random variables. We propose a neural network model and show by a rigorous theoretical analysis that its neural activity implements MCMC sampling of a given distribution, both for the case of discrete and continuous time. This provides a step towards closing the gap between abstract functional models of cortical computation and more detailed models of networks of spiking neurons.

  4. Sample test cases using the environmental computer code NECTAR

    International Nuclear Information System (INIS)

    Ponting, A.C.

    1984-06-01

    This note demonstrates a few of the many different ways in which the environmental computer code NECTAR may be used. Four sample test cases are presented and described to show how NECTAR input data are structured. Edited output is also presented to illustrate the format of the results. Two test cases demonstrate how NECTAR may be used to study radio-isotopes not explicitly included in the code. (U.K.)

  5. Equilibrium partitioning of macromolecules in confining geometries: Improved universality with a new molecular size parameter

    DEFF Research Database (Denmark)

    Wang, Yanwei; Peters, Günther H.J.; Hansen, Flemming Yssing

    2008-01-01

    structures (CABS), allows the computation of equilibrium partition coefficients as a function of confinement size solely based on a single sampling of the configuration space of a macromolecule in bulk. Superior in computational speed to previous computational methods, CABS is capable of handling slits...... parameter for characterization of spatial confinement effects on macromolecules. Results for the equilibrium partition coefficient in the weak confinement regime depend only on the ratio ofR-s to the confinement size regardless of molecular details....

  6. Size-Resolved Penetration Through High-Efficiency Filter Media Typically Used for Aerosol Sampling

    Czech Academy of Sciences Publication Activity Database

    Zíková, Naděžda; Ondráček, Jakub; Ždímal, Vladimír

    2015-01-01

    Roč. 49, č. 4 (2015), s. 239-249 ISSN 0278-6826 R&D Projects: GA ČR(CZ) GBP503/12/G147 Institutional support: RVO:67985858 Keywords : filters * size-resolved penetration * atmospheric aerosol sampling Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.953, year: 2015

  7. A simple sample size formula for analysis of covariance in cluster randomized trials.

    NARCIS (Netherlands)

    Teerenstra, S.; Eldridge, S.; Graff, M.J.; Hoop, E. de; Borm, G.F.

    2012-01-01

    For cluster randomized trials with a continuous outcome, the sample size is often calculated as if an analysis of the outcomes at the end of the treatment period (follow-up scores) would be performed. However, often a baseline measurement of the outcome is available or feasible to obtain. An

  8. Analysis of small sample size studies using nonparametric bootstrap test with pooled resampling method.

    Science.gov (United States)

    Dwivedi, Alok Kumar; Mallawaarachchi, Indika; Alvarado, Luis A

    2017-06-30

    Experimental studies in biomedical research frequently pose analytical problems related to small sample size. In such studies, there are conflicting findings regarding the choice of parametric and nonparametric analysis, especially with non-normal data. In such instances, some methodologists questioned the validity of parametric tests and suggested nonparametric tests. In contrast, other methodologists found nonparametric tests to be too conservative and less powerful and thus preferred using parametric tests. Some researchers have recommended using a bootstrap test; however, this method also has small sample size limitation. We used a pooled method in nonparametric bootstrap test that may overcome the problem related with small samples in hypothesis testing. The present study compared nonparametric bootstrap test with pooled resampling method corresponding to parametric, nonparametric, and permutation tests through extensive simulations under various conditions and using real data examples. The nonparametric pooled bootstrap t-test provided equal or greater power for comparing two means as compared with unpaired t-test, Welch t-test, Wilcoxon rank sum test, and permutation test while maintaining type I error probability for any conditions except for Cauchy and extreme variable lognormal distributions. In such cases, we suggest using an exact Wilcoxon rank sum test. Nonparametric bootstrap paired t-test also provided better performance than other alternatives. Nonparametric bootstrap test provided benefit over exact Kruskal-Wallis test. We suggest using nonparametric bootstrap test with pooled resampling method for comparing paired or unpaired means and for validating the one way analysis of variance test results for non-normal data in small sample size studies. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. An efficient computational method for a stochastic dynamic lot-sizing problem under service-level constraints

    NARCIS (Netherlands)

    Tarim, S.A.; Ozen, U.; Dogru, M.K.; Rossi, R.

    2011-01-01

    We provide an efficient computational approach to solve the mixed integer programming (MIP) model developed by Tarim and Kingsman [8] for solving a stochastic lot-sizing problem with service level constraints under the static–dynamic uncertainty strategy. The effectiveness of the proposed method

  10. Sample sizes to control error estimates in determining soil bulk density in California forest soils

    Science.gov (United States)

    Youzhi Han; Jianwei Zhang; Kim G. Mattson; Weidong Zhang; Thomas A. Weber

    2016-01-01

    Characterizing forest soil properties with high variability is challenging, sometimes requiring large numbers of soil samples. Soil bulk density is a standard variable needed along with element concentrations to calculate nutrient pools. This study aimed to determine the optimal sample size, the number of observation (n), for predicting the soil bulk density with a...

  11. Size-segregated urban aerosol characterization by electron microscopy and dynamic light scattering and influence of sample preparation

    Science.gov (United States)

    Marvanová, Soňa; Kulich, Pavel; Skoupý, Radim; Hubatka, František; Ciganek, Miroslav; Bendl, Jan; Hovorka, Jan; Machala, Miroslav

    2018-04-01

    Size-segregated particulate matter (PM) is frequently used in chemical and toxicological studies. Nevertheless, toxicological in vitro studies working with the whole particles often lack a proper evaluation of PM real size distribution and characterization of agglomeration under the experimental conditions. In this study, changes in particle size distributions during the PM sample manipulation and also semiquantitative elemental composition of single particles were evaluated. Coarse (1-10 μm), upper accumulation (0.5-1 μm), lower accumulation (0.17-0.5 μm), and ultrafine (culture media. PM suspension of lower accumulation fraction in water agglomerated after freezing/thawing the sample, and the agglomerates were disrupted by subsequent sonication. Ultrafine fraction did not agglomerate after freezing/thawing the sample. Both lower accumulation and ultrafine fractions were stable in cell culture media with fetal bovine serum, while high agglomeration occurred in media without fetal bovine serum as measured during 24 h.

  12. Clustering for high-dimension, low-sample size data using distance vectors

    OpenAIRE

    Terada, Yoshikazu

    2013-01-01

    In high-dimension, low-sample size (HDLSS) data, it is not always true that closeness of two objects reflects a hidden cluster structure. We point out the important fact that it is not the closeness, but the "values" of distance that contain information of the cluster structure in high-dimensional space. Based on this fact, we propose an efficient and simple clustering approach, called distance vector clustering, for HDLSS data. Under the assumptions given in the work of Hall et al. (2005), w...

  13. Power and Sample Size Calculations for Logistic Regression Tests for Differential Item Functioning

    Science.gov (United States)

    Li, Zhushan

    2014-01-01

    Logistic regression is a popular method for detecting uniform and nonuniform differential item functioning (DIF) effects. Theoretical formulas for the power and sample size calculations are derived for likelihood ratio tests and Wald tests based on the asymptotic distribution of the maximum likelihood estimators for the logistic regression model.…

  14. Sample Size Calculation for Estimating or Testing a Nonzero Squared Multiple Correlation Coefficient

    Science.gov (United States)

    Krishnamoorthy, K.; Xia, Yanping

    2008-01-01

    The problems of hypothesis testing and interval estimation of the squared multiple correlation coefficient of a multivariate normal distribution are considered. It is shown that available one-sided tests are uniformly most powerful, and the one-sided confidence intervals are uniformly most accurate. An exact method of calculating sample size to…

  15. Sample Size Calculation: Inaccurate A Priori Assumptions for Nuisance Parameters Can Greatly Affect the Power of a Randomized Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Elsa Tavernier

    Full Text Available We aimed to examine the extent to which inaccurate assumptions for nuisance parameters used to calculate sample size can affect the power of a randomized controlled trial (RCT. In a simulation study, we separately considered an RCT with continuous, dichotomous or time-to-event outcomes, with associated nuisance parameters of standard deviation, success rate in the control group and survival rate in the control group at some time point, respectively. For each type of outcome, we calculated a required sample size N for a hypothesized treatment effect, an assumed nuisance parameter and a nominal power of 80%. We then assumed a nuisance parameter associated with a relative error at the design stage. For each type of outcome, we randomly drew 10,000 relative errors of the associated nuisance parameter (from empirical distributions derived from a previously published review. Then, retro-fitting the sample size formula, we derived, for the pre-calculated sample size N, the real power of the RCT, taking into account the relative error for the nuisance parameter. In total, 23%, 0% and 18% of RCTs with continuous, binary and time-to-event outcomes, respectively, were underpowered (i.e., the real power was 90%. Even with proper calculation of sample size, a substantial number of trials are underpowered or overpowered because of imprecise knowledge of nuisance parameters. Such findings raise questions about how sample size for RCTs should be determined.

  16. Computational workflow for the fine-grained analysis of metagenomic samples.

    Science.gov (United States)

    Pérez-Wohlfeil, Esteban; Arjona-Medina, Jose A; Torreno, Oscar; Ulzurrun, Eugenia; Trelles, Oswaldo

    2016-10-25

    The field of metagenomics, defined as the direct genetic analysis of uncultured samples of genomes contained within an environmental sample, is gaining increasing popularity. The aim of studies of metagenomics is to determine the species present in an environmental community and identify changes in the abundance of species under different conditions. Current metagenomic analysis software faces bottlenecks due to the high computational load required to analyze complex samples. A computational open-source workflow has been developed for the detailed analysis of metagenomes. This workflow provides new tools and datafile specifications that facilitate the identification of differences in abundance of reads assigned to taxa (mapping), enables the detection of reads of low-abundance bacteria (producing evidence of their presence), provides new concepts for filtering spurious matches, etc. Innovative visualization ideas for improved display of metagenomic diversity are also proposed to better understand how reads are mapped to taxa. Illustrative examples are provided based on the study of two collections of metagenomes from faecal microbial communities of adult female monozygotic and dizygotic twin pairs concordant for leanness or obesity and their mothers. The proposed workflow provides an open environment that offers the opportunity to perform the mapping process using different reference databases. Additionally, this workflow shows the specifications of the mapping process and datafile formats to facilitate the development of new plugins for further post-processing. This open and extensible platform has been designed with the aim of enabling in-depth analysis of metagenomic samples and better understanding of the underlying biological processes.

  17. Computational workflow for the fine-grained analysis of metagenomic samples

    Directory of Open Access Journals (Sweden)

    Esteban Pérez-Wohlfeil

    2016-10-01

    Full Text Available Abstract Background The field of metagenomics, defined as the direct genetic analysis of uncultured samples of genomes contained within an environmental sample, is gaining increasing popularity. The aim of studies of metagenomics is to determine the species present in an environmental community and identify changes in the abundance of species under different conditions. Current metagenomic analysis software faces bottlenecks due to the high computational load required to analyze complex samples. Results A computational open-source workflow has been developed for the detailed analysis of metagenomes. This workflow provides new tools and datafile specifications that facilitate the identification of differences in abundance of reads assigned to taxa (mapping, enables the detection of reads of low-abundance bacteria (producing evidence of their presence, provides new concepts for filtering spurious matches, etc. Innovative visualization ideas for improved display of metagenomic diversity are also proposed to better understand how reads are mapped to taxa. Illustrative examples are provided based on the study of two collections of metagenomes from faecal microbial communities of adult female monozygotic and dizygotic twin pairs concordant for leanness or obesity and their mothers. Conclusions The proposed workflow provides an open environment that offers the opportunity to perform the mapping process using different reference databases. Additionally, this workflow shows the specifications of the mapping process and datafile formats to facilitate the development of new plugins for further post-processing. This open and extensible platform has been designed with the aim of enabling in-depth analysis of metagenomic samples and better understanding of the underlying biological processes.

  18. Sample Size Bounding and Context Ranking as Approaches to the Human Error Quantification Problem

    Energy Technology Data Exchange (ETDEWEB)

    Reer, B

    2004-03-01

    The paper describes a technique denoted as Sub-Sample-Size Bounding (SSSB), which is useable for the statistical derivation of context-specific probabilities from data available in existing reports on operating experience. Applications to human reliability analysis (HRA) are emphasised in the presentation of this technique. Exemplified by a sample of 180 abnormal event sequences, the manner in which SSSB can provide viable input for the quantification of errors of commission (EOCs) are outlined. (author)

  19. Sample Size Bounding and Context Ranking as Approaches to the Human Error Quantification Problem

    International Nuclear Information System (INIS)

    Reer, B.

    2004-01-01

    The paper describes a technique denoted as Sub-Sample-Size Bounding (SSSB), which is useable for the statistical derivation of context-specific probabilities from data available in existing reports on operating experience. Applications to human reliability analysis (HRA) are emphasised in the presentation of this technique. Exemplified by a sample of 180 abnormal event sequences, the manner in which SSSB can provide viable input for the quantification of errors of commission (EOCs) are outlined. (author)

  20. A method of language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik; Hengeveld, Kees

    1993-01-01

    In recent years more attention is paid to the quality of language samples in typological work. Without an adequate sampling strategy, samples may suffer from various kinds of bias. In this article we propose a sampling method in which the genetic criterion is taken as the most important: samples...... created with this method will reflect optimally the diversity of the languages of the world. On the basis of the internal structure of each genetic language tree a measure is computed that reflects the linguistic diversity in the language families represented by these trees. This measure is used...... to determine how many languages from each phylum should be selected, given any required sample size....

  1. Three-dimensional computed tomography measurement accuracy of varying Hill-Sachs lesion size.

    Science.gov (United States)

    Ho, Anthony; Kurdziel, Michael D; Koueiter, Denise M; Wiater, J Michael

    2018-02-01

    The glenoid track concept has been proposed to correlate shoulder stability with bone loss. Accurate assessment of Hill-Sachs lesion size preoperatively may affect surgical planning and postoperative outcomes; however, no measurement method has been universally accepted. This study aimed to assess the accuracy and reliability of measuring Hill-Sachs lesion sizes using 3-dimensional (3D) computed tomography (CT). Nine polyurethane humerus bone substitutes were used to create Hill-Sachs lesions of varying sizes with a combination of lesion depth (shallow, intermediate, and deep) and width (small, medium, and large). Specimens were scanned with a clinical CT scanner for size measurements and a micro-CT scanner for measurement of true lesion size. Six evaluators repeated measurements twice in a 2-week interval. Scans were measured by use of 3D CT reconstructions for length, width, and Hill-Sachs interval and with use of 2D CT for depth. The interclass correlation coefficient evaluated interobserver and intraobserver variability and percentage error, and Student t-tests assessed measurement accuracy. Interclass correlation coefficient reliability demonstrated strong agreement for all variables measured (0.856-0.975). Percentage error between measured length and measured depth and the true measurement significantly varied with respect to both lesion depth (P = .003 and P = .005, respectively) and lesion size (P = .049 and P = .004, respectively). The 3D CT imaging is effective and reproducible in determining lesion size. Determination of Hill-Sachs interval width is also reliable when it is applied to the glenoid track concept. Measured values on 3D and 2-dimensional imaging using a conventional CT scanner may slightly underestimate true measurements. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  2. Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses

    International Nuclear Information System (INIS)

    Huda, Walter; Lieberman, Kristin A.; Chang, Jack; Roskopf, Marsha L.

    2004-01-01

    We investigated how patient age, size and composition, together with the choice of x-ray technique factors, affect radiation doses in head computed tomography (CT) examinations. Head size dimensions, cross-sectional areas, and mean Hounsfield unit (HU) values were obtained from head CT images of 127 patients. For radiation dosimetry purposes patients were modeled as uniform cylinders of water. Dose computations were performed for 18x7 mm sections, scanned at a constant 340 mAs, for x-ray tube voltages ranging from 80 to 140 kV. Values of mean section dose, energy imparted, and effective dose were computed for patients ranging from the newborn to adults. There was a rapid growth of head size over the first two years, followed by a more modest increase of head size until the age of 18 or so. Newborns have a mean HU value of about 50 that monotonically increases with age over the first two decades of life. Average adult A-P and lateral dimensions were 186±8 mm and 147±8 mm, respectively, with an average HU value of 209±40. An infant head was found to be equivalent to a water cylinder with a radius of ∼60 mm, whereas an adult head had an equivalent radius 50% greater. Adult males head dimensions are about 5% larger than for females, and their average x-ray attenuation is ∼20 HU greater. For adult examinations performed at 120 kV, typical values were 32 mGy for the mean section dose, 105 mJ for the total energy imparted, and 0.64 mSv for the effective dose. Increasing the x-ray tube voltage from 80 to 140 kV increases patient doses by about a factor of 5. For the same technique factors, mean section doses in infants are 35% higher than in adults. Energy imparted for adults is 50% higher than for infants, but infant effective doses are four times higher than for adults. CT doses need to take into account patient age, head size, and composition as well as the selected x-ray technique factors

  3. Effects of growth rate, size, and light availability on tree survival across life stages: a demographic analysis accounting for missing values and small sample sizes.

    Science.gov (United States)

    Moustakas, Aristides; Evans, Matthew R

    2015-02-28

    Plant survival is a key factor in forest dynamics and survival probabilities often vary across life stages. Studies specifically aimed at assessing tree survival are unusual and so data initially designed for other purposes often need to be used; such data are more likely to contain errors than data collected for this specific purpose. We investigate the survival rates of ten tree species in a dataset designed to monitor growth rates. As some individuals were not included in the census at some time points we use capture-mark-recapture methods both to allow us to account for missing individuals, and to estimate relocation probabilities. Growth rates, size, and light availability were included as covariates in the model predicting survival rates. The study demonstrates that tree mortality is best described as constant between years and size-dependent at early life stages and size independent at later life stages for most species of UK hardwood. We have demonstrated that even with a twenty-year dataset it is possible to discern variability both between individuals and between species. Our work illustrates the potential utility of the method applied here for calculating plant population dynamics parameters in time replicated datasets with small sample sizes and missing individuals without any loss of sample size, and including explanatory covariates.

  4. Development of a sampling strategy and sample size calculation to estimate the distribution of mammographic breast density in Korean women.

    Science.gov (United States)

    Jun, Jae Kwan; Kim, Mi Jin; Choi, Kui Son; Suh, Mina; Jung, Kyu-Won

    2012-01-01

    Mammographic breast density is a known risk factor for breast cancer. To conduct a survey to estimate the distribution of mammographic breast density in Korean women, appropriate sampling strategies for representative and efficient sampling design were evaluated through simulation. Using the target population from the National Cancer Screening Programme (NCSP) for breast cancer in 2009, we verified the distribution estimate by repeating the simulation 1,000 times using stratified random sampling to investigate the distribution of breast density of 1,340,362 women. According to the simulation results, using a sampling design stratifying the nation into three groups (metropolitan, urban, and rural), with a total sample size of 4,000, we estimated the distribution of breast density in Korean women at a level of 0.01% tolerance. Based on the results of our study, a nationwide survey for estimating the distribution of mammographic breast density among Korean women can be conducted efficiently.

  5. Sample size calculations based on a difference in medians for positively skewed outcomes in health care studies

    Directory of Open Access Journals (Sweden)

    Aidan G. O’Keeffe

    2017-12-01

    Full Text Available Abstract Background In healthcare research, outcomes with skewed probability distributions are common. Sample size calculations for such outcomes are typically based on estimates on a transformed scale (e.g. log which may sometimes be difficult to obtain. In contrast, estimates of median and variance on the untransformed scale are generally easier to pre-specify. The aim of this paper is to describe how to calculate a sample size for a two group comparison of interest based on median and untransformed variance estimates for log-normal outcome data. Methods A log-normal distribution for outcome data is assumed and a sample size calculation approach for a two-sample t-test that compares log-transformed outcome data is demonstrated where the change of interest is specified as difference in median values on the untransformed scale. A simulation study is used to compare the method with a non-parametric alternative (Mann-Whitney U test in a variety of scenarios and the method is applied to a real example in neurosurgery. Results The method attained a nominal power value in simulation studies and was favourable in comparison to a Mann-Whitney U test and a two-sample t-test of untransformed outcomes. In addition, the method can be adjusted and used in some situations where the outcome distribution is not strictly log-normal. Conclusions We recommend the use of this sample size calculation approach for outcome data that are expected to be positively skewed and where a two group comparison on a log-transformed scale is planned. An advantage of this method over usual calculations based on estimates on the log-transformed scale is that it allows clinical efficacy to be specified as a difference in medians and requires a variance estimate on the untransformed scale. Such estimates are often easier to obtain and more interpretable than those for log-transformed outcomes.

  6. Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range.

    Science.gov (United States)

    Wan, Xiang; Wang, Wenqian; Liu, Jiming; Tong, Tiejun

    2014-12-19

    In systematic reviews and meta-analysis, researchers often pool the results of the sample mean and standard deviation from a set of similar clinical trials. A number of the trials, however, reported the study using the median, the minimum and maximum values, and/or the first and third quartiles. Hence, in order to combine results, one may have to estimate the sample mean and standard deviation for such trials. In this paper, we propose to improve the existing literature in several directions. First, we show that the sample standard deviation estimation in Hozo et al.'s method (BMC Med Res Methodol 5:13, 2005) has some serious limitations and is always less satisfactory in practice. Inspired by this, we propose a new estimation method by incorporating the sample size. Second, we systematically study the sample mean and standard deviation estimation problem under several other interesting settings where the interquartile range is also available for the trials. We demonstrate the performance of the proposed methods through simulation studies for the three frequently encountered scenarios, respectively. For the first two scenarios, our method greatly improves existing methods and provides a nearly unbiased estimate of the true sample standard deviation for normal data and a slightly biased estimate for skewed data. For the third scenario, our method still performs very well for both normal data and skewed data. Furthermore, we compare the estimators of the sample mean and standard deviation under all three scenarios and present some suggestions on which scenario is preferred in real-world applications. In this paper, we discuss different approximation methods in the estimation of the sample mean and standard deviation and propose some new estimation methods to improve the existing literature. We conclude our work with a summary table (an Excel spread sheet including all formulas) that serves as a comprehensive guidance for performing meta-analysis in different

  7. In vitro rumen feed degradability assessed with DaisyII and batch culture: effect of sample size

    Directory of Open Access Journals (Sweden)

    Stefano Schiavon

    2010-01-01

    Full Text Available In vitro degradability with DaisyII (D equipment is commonly performed with 0.5g of feed sample into each filter bag. Literature reported that a reduction of the ratio of sample size to bag surface could facilitate the release of soluble or fine particulate. A reduction of sample size to 0.25 g could improve the correlation between the measurements provided by D and the conventional batch culture (BC. This hypothesis was screened by analysing the results of 2 trials. In trial 1, 7 feeds were incubated for 48h with rumen fluid (3 runs x 4 replications both with D (0.5g/bag and BC; the regressions between the mean values provided for the various feeds in each run by the 2 methods either for NDF (NDFd and in vitro true DM (IVTDMD degradability, had R2 of 0.75 and 0.92 and RSD of 10.9 and 4.8%, respectively. In trial 2, 4 feeds were incubated (2 runs x 8 replications with D (0.25 g/bag and BC; the corresponding regressions for NDFd and IVTDMD showed R2 of 0.94 and 0.98 and RSD of 3.0 and 1.3%, respectively. A sample size of 0.25 g improved the precision of the measurements obtained with D.

  8. Performance and separation occurrence of binary probit regression estimator using maximum likelihood method and Firths approach under different sample size

    Science.gov (United States)

    Lusiana, Evellin Dewi

    2017-12-01

    The parameters of binary probit regression model are commonly estimated by using Maximum Likelihood Estimation (MLE) method. However, MLE method has limitation if the binary data contains separation. Separation is the condition where there are one or several independent variables that exactly grouped the categories in binary response. It will result the estimators of MLE method become non-convergent, so that they cannot be used in modeling. One of the effort to resolve the separation is using Firths approach instead. This research has two aims. First, to identify the chance of separation occurrence in binary probit regression model between MLE method and Firths approach. Second, to compare the performance of binary probit regression model estimator that obtained by MLE method and Firths approach using RMSE criteria. Those are performed using simulation method and under different sample size. The results showed that the chance of separation occurrence in MLE method for small sample size is higher than Firths approach. On the other hand, for larger sample size, the probability decreased and relatively identic between MLE method and Firths approach. Meanwhile, Firths estimators have smaller RMSE than MLEs especially for smaller sample sizes. But for larger sample sizes, the RMSEs are not much different. It means that Firths estimators outperformed MLE estimator.

  9. Sample size estimation to substantiate freedom from disease for clustered binary data with a specific risk profile

    DEFF Research Database (Denmark)

    Kostoulas, P.; Nielsen, Søren Saxmose; Browne, W. J.

    2013-01-01

    and power when applied to these groups. We propose the use of the variance partition coefficient (VPC), which measures the clustering of infection/disease for individuals with a common risk profile. Sample size estimates are obtained separately for those groups that exhibit markedly different heterogeneity......, thus, optimizing resource allocation. A VPC-based predictive simulation method for sample size estimation to substantiate freedom from disease is presented. To illustrate the benefits of the proposed approach we give two examples with the analysis of data from a risk factor study on Mycobacterium avium...

  10. Analysis of time series and size of equivalent sample

    International Nuclear Information System (INIS)

    Bernal, Nestor; Molina, Alicia; Pabon, Daniel; Martinez, Jorge

    2004-01-01

    In a meteorological context, a first approach to the modeling of time series is to use models of autoregressive type. This allows one to take into account the meteorological persistence or temporal behavior, thereby identifying the memory of the analyzed process. This article seeks to pre-sent the concept of the size of an equivalent sample, which helps to identify in the data series sub periods with a similar structure. Moreover, in this article we examine the alternative of adjusting the variance of the series, keeping in mind its temporal structure, as well as an adjustment to the covariance of two time series. This article presents two examples, the first one corresponding to seven simulated series with autoregressive structure of first order, and the second corresponding to seven meteorological series of anomalies of the air temperature at the surface in two Colombian regions

  11. ANALYSIS OF MONTE CARLO SIMULATION SAMPLING TECHNIQUES ON SMALL SIGNAL STABILITY OF WIND GENERATOR- CONNECTED POWER SYSTEM

    Directory of Open Access Journals (Sweden)

    TEMITOPE RAPHAEL AYODELE

    2016-04-01

    Full Text Available Monte Carlo simulation using Simple Random Sampling (SRS technique is popularly known for its ability to handle complex uncertainty problems. However, to produce a reasonable result, it requires huge sample size. This makes it to be computationally expensive, time consuming and unfit for online power system applications. In this article, the performance of Latin Hypercube Sampling (LHS technique is explored and compared with SRS in term of accuracy, robustness and speed for small signal stability application in a wind generator-connected power system. The analysis is performed using probabilistic techniques via eigenvalue analysis on two standard networks (Single Machine Infinite Bus and IEEE 16–machine 68 bus test system. The accuracy of the two sampling techniques is determined by comparing their different sample sizes with the IDEAL (conventional. The robustness is determined based on a significant variance reduction when the experiment is repeated 100 times with different sample sizes using the two sampling techniques in turn. Some of the results show that sample sizes generated from LHS for small signal stability application produces the same result as that of the IDEAL values starting from 100 sample size. This shows that about 100 sample size of random variable generated using LHS method is good enough to produce reasonable results for practical purpose in small signal stability application. It is also revealed that LHS has the least variance when the experiment is repeated 100 times compared to SRS techniques. This signifies the robustness of LHS over that of SRS techniques. 100 sample size of LHS produces the same result as that of the conventional method consisting of 50000 sample size. The reduced sample size required by LHS gives it computational speed advantage (about six times over the conventional method.

  12. Sample size requirements for studies of treatment effects on beta-cell function in newly diagnosed type 1 diabetes.

    Science.gov (United States)

    Lachin, John M; McGee, Paula L; Greenbaum, Carla J; Palmer, Jerry; Pescovitz, Mark D; Gottlieb, Peter; Skyler, Jay

    2011-01-01

    Preservation of β-cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet), repeated 2-hour Mixed Meal Tolerance Tests (MMTT) were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC) of the C-peptide values. The natural log(x), log(x+1) and square-root (√x) transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8-12 years of age, adolescents (13-17 years) and adults (18+ years). The sample size needed to detect a given relative (percentage) difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13-17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(x+1) and √x transformed values in terms of the original units of measurement (pmol/ml). Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab) versus masked placebo. These results provide the information needed to accurately

  13. Sample size requirements for studies of treatment effects on beta-cell function in newly diagnosed type 1 diabetes.

    Directory of Open Access Journals (Sweden)

    John M Lachin

    Full Text Available Preservation of β-cell function as measured by stimulated C-peptide has recently been accepted as a therapeutic target for subjects with newly diagnosed type 1 diabetes. In recently completed studies conducted by the Type 1 Diabetes Trial Network (TrialNet, repeated 2-hour Mixed Meal Tolerance Tests (MMTT were obtained for up to 24 months from 156 subjects with up to 3 months duration of type 1 diabetes at the time of study enrollment. These data provide the information needed to more accurately determine the sample size needed for future studies of the effects of new agents on the 2-hour area under the curve (AUC of the C-peptide values. The natural log(x, log(x+1 and square-root (√x transformations of the AUC were assessed. In general, a transformation of the data is needed to better satisfy the normality assumptions for commonly used statistical tests. Statistical analysis of the raw and transformed data are provided to estimate the mean levels over time and the residual variation in untreated subjects that allow sample size calculations for future studies at either 12 or 24 months of follow-up and among children 8-12 years of age, adolescents (13-17 years and adults (18+ years. The sample size needed to detect a given relative (percentage difference with treatment versus control is greater at 24 months than at 12 months of follow-up, and differs among age categories. Owing to greater residual variation among those 13-17 years of age, a larger sample size is required for this age group. Methods are also described for assessment of sample size for mixtures of subjects among the age categories. Statistical expressions are presented for the presentation of analyses of log(x+1 and √x transformed values in terms of the original units of measurement (pmol/ml. Analyses using different transformations are described for the TrialNet study of masked anti-CD20 (rituximab versus masked placebo. These results provide the information needed to

  14. Prognostic Significance of Tumor Size of Small Lung Adenocarcinomas Evaluated with Mediastinal Window Settings on Computed Tomography

    OpenAIRE

    Sakao, Yukinori; Kuroda, Hiroaki; Mun, Mingyon; Uehara, Hirofumi; Motoi, Noriko; Ishikawa, Yuichi; Nakagawa, Ken; Okumura, Sakae

    2014-01-01

    BACKGROUND: We aimed to clarify that the size of the lung adenocarcinoma evaluated using mediastinal window on computed tomography is an important and useful modality for predicting invasiveness, lymph node metastasis and prognosis in small adenocarcinoma. METHODS: We evaluated 176 patients with small lung adenocarcinomas (diameter, 1-3 cm) who underwent standard surgical resection. Tumours were examined using computed tomography with thin section conditions (1.25 mm thick on high-resolution ...

  15. On the Influence of the Data Sampling Interval on Computer-Derived K-Indices

    Directory of Open Access Journals (Sweden)

    A Bernard

    2011-06-01

    Full Text Available The K index was devised by Bartels et al. (1939 to provide an objective monitoring of irregular geomagnetic activity. The K index was then routinely used to monitor the magnetic activity at permanent magnetic observatories as well as at temporary stations. The increasing number of digital and sometimes unmanned observatories and the creation of INTERMAGNET put the question of computer production of K at the centre of the debate. Four algorithms were selected during the Vienna meeting (1991 and endorsed by IAGA for the computer production of K indices. We used one of them (FMI algorithm to investigate the impact of the geomagnetic data sampling interval on computer produced K values through the comparison of the computer derived K values for the period 2009, January 1st to 2010, May 31st at the Port-aux-Francais magnetic observatory using magnetic data series with different sampling rates (the smaller: 1 second; the larger: 1 minute. The impact is investigated on both 3-hour range values and K indices data series, as a function of the activity level for low and moderate geomagnetic activity.

  16. Sample size for comparing negative binomial rates in noninferiority and equivalence trials with unequal follow-up times.

    Science.gov (United States)

    Tang, Yongqiang

    2017-05-25

    We derive the sample size formulae for comparing two negative binomial rates based on both the relative and absolute rate difference metrics in noninferiority and equivalence trials with unequal follow-up times, and establish an approximate relationship between the sample sizes required for the treatment comparison based on the two treatment effect metrics. The proposed method allows the dispersion parameter to vary by treatment groups. The accuracy of these methods is assessed by simulations. It is demonstrated that ignoring the between-subject variation in the follow-up time by setting the follow-up time for all individuals to be the mean follow-up time may greatly underestimate the required size, resulting in underpowered studies. Methods are provided for back-calculating the dispersion parameter based on the published summary results.

  17. Computed Tomographic Window Setting for Bronchial Measurement to Guide Double-Lumen Tube Size.

    Science.gov (United States)

    Seo, Jeong-Hwa; Bae, Jinyoung; Paik, Hyesun; Koo, Chang-Hoon; Bahk, Jae-Hyon

    2018-04-01

    The bronchial diameter measured on computed tomography (CT) can be used to guide double-lumen tube (DLT) sizes objectively. The bronchus is known to be measured most accurately in the so-called bronchial CT window. The authors investigated whether using the bronchial window results in the selection of more appropriately sized DLTs than using the other windows. CT image analysis and prospective randomized study. Tertiary hospital. Adults receiving left-sided DLTs. The authors simulated selection of DLT sizes based on the left bronchial diameters measured in the lung (width 1,500 Hounsfield unit [HU] and level -700 HU), bronchial (1,000 HU and -450 HU), and mediastinal (400 HU and 25 HU) CT windows. Furthermore, patients were randomly assigned to undergo imaging with either the bronchial or mediastinal window to guide DLT sizes. Using the underwater seal technique, the authors assessed whether the DLT was appropriately sized, undersized, or oversized for the patient. On 130 CT images, the bronchial diameter (9.9 ± 1.2 mm v 10.5 ± 1.3 mm v 11.7 ± 1.3 mm) and the selected DLT size were different in the lung, bronchial, and mediastinal windows, respectively (p study, oversized tubes were chosen less frequently in the bronchial window than in the mediastinal window (6/110 v 23/111; risk ratio 0.38; 95% CI 0.19-0.79; p = 0.003). No tubes were undersized after measurements in these two windows. The bronchial measurement in the bronchial window guided more appropriately sized DLTs compared with the lung or mediastinal windows. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Sampling of illicit drugs for quantitative analysis--part II. Study of particle size and its influence on mass reduction.

    Science.gov (United States)

    Bovens, M; Csesztregi, T; Franc, A; Nagy, J; Dujourdy, L

    2014-01-01

    The basic goal in sampling for the quantitative analysis of illicit drugs is to maintain the average concentration of the drug in the material from its original seized state (the primary sample) all the way through to the analytical sample, where the effect of particle size is most critical. The size of the largest particles of different authentic illicit drug materials, in their original state and after homogenisation, using manual or mechanical procedures, was measured using a microscope with a camera attachment. The comminution methods employed included pestle and mortar (manual) and various ball and knife mills (mechanical). The drugs investigated were amphetamine, heroin, cocaine and herbal cannabis. It was shown that comminution of illicit drug materials using these techniques reduces the nominal particle size from approximately 600 μm down to between 200 and 300 μm. It was demonstrated that the choice of 1 g increments for the primary samples of powdered drugs and cannabis resin, which were used in the heterogeneity part of our study (Part I) was correct for the routine quantitative analysis of illicit seized drugs. For herbal cannabis we found that the appropriate increment size was larger. Based on the results of this study we can generally state that: An analytical sample weight of between 20 and 35 mg of an illicit powdered drug, with an assumed purity of 5% or higher, would be considered appropriate and would generate an RSDsampling in the same region as the RSDanalysis for a typical quantitative method of analysis for the most common, powdered, illicit drugs. For herbal cannabis, with an assumed purity of 1% THC (tetrahydrocannabinol) or higher, an analytical sample weight of approximately 200 mg would be appropriate. In Part III we will pull together our homogeneity studies and particle size investigations and use them to devise sampling plans and sample preparations suitable for the quantitative instrumental analysis of the most common illicit

  19. Evaluation of species richness estimators based on quantitative performance measures and sensitivity to patchiness and sample grain size

    Science.gov (United States)

    Willie, Jacob; Petre, Charles-Albert; Tagg, Nikki; Lens, Luc

    2012-11-01

    Data from forest herbaceous plants in a site of known species richness in Cameroon were used to test the performance of rarefaction and eight species richness estimators (ACE, ICE, Chao1, Chao2, Jack1, Jack2, Bootstrap and MM). Bias, accuracy, precision and sensitivity to patchiness and sample grain size were the evaluation criteria. An evaluation of the effects of sampling effort and patchiness on diversity estimation is also provided. Stems were identified and counted in linear series of 1-m2 contiguous square plots distributed in six habitat types. Initially, 500 plots were sampled in each habitat type. The sampling process was monitored using rarefaction and a set of richness estimator curves. Curves from the first dataset suggested adequate sampling in riparian forest only. Additional plots ranging from 523 to 2143 were subsequently added in the undersampled habitats until most of the curves stabilized. Jack1 and ICE, the non-parametric richness estimators, performed better, being more accurate and less sensitive to patchiness and sample grain size, and significantly reducing biases that could not be detected by rarefaction and other estimators. This study confirms the usefulness of non-parametric incidence-based estimators, and recommends Jack1 or ICE alongside rarefaction while describing taxon richness and comparing results across areas sampled using similar or different grain sizes. As patchiness varied across habitat types, accurate estimations of diversity did not require the same number of plots. The number of samples needed to fully capture diversity is not necessarily the same across habitats, and can only be known when taxon sampling curves have indicated adequate sampling. Differences in observed species richness between habitats were generally due to differences in patchiness, except between two habitats where they resulted from differences in abundance. We suggest that communities should first be sampled thoroughly using appropriate taxon sampling

  20. Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device.

    Science.gov (United States)

    Xu, Bo; Betancor, Jorge; Sato, Kimi; Harb, Serge; Abdur Rehman, Karim; Patel, Kunal; Kumar, Arnav; Cremer, Paul C; Jaber, Wael; Rodriguez, L Leonardo; Schoenhagen, Paul; Wazni, Oussama

    Percutaneous left atrial appendage (LAA) occlusion is an emerging treatment option for patients with non-valvular atrial fibrillation who cannot tolerate oral anticoagulation. The Watchman device (Boston Scientific Corporation, Natick, MA, USA) is deployed at the ostium of the LAA, and an appropriately sized device is critical for successful occlusion. However, standardized imaging protocols for device sizing have not been established. We investigated the clinical utility of a standardized imaging protocol, with pre-procedural multi-detector cardiac computed tomography (MDCT), and intra-procedural transesophageal echocardiography (TEE), for Watchman device sizing. Patients who underwent Watchman device implantation between 2010 and 2016 at our center, and who had pre-procedural MDCT and intra-procedural TEE were included. MDCT measurements (CTmax, CTmin, CTmean), and TEE measurement (TEEmax) of the LAA ostium were determined for each case, and correlated with the final size of the Watchman device implanted. Demographic data and clinical outcomes were collected. The study included 80 patients (mean age: 75 ± 9.6 years; male: 68%; mean CHA2DS2-VASc score: 4.5 ± 1.4). CTmax of the LAA ostium correlated strongly with the final deployed Watchman device size (Spearman's rho: 0.81, p < 0.001), while TEEmax of the LAA ostium showed only moderate correlation with the final deployed Watchman device size (Spearman's rho: 0.61, p < 0.001). Implantation success rate was 100%. At a mean duration of follow-up of 197 days, there were no device-related complications (device embolization, cardiac perforation and pericardial tamponade). At follow-up, the vast majority of patients (76 patients; 95%) had either no or trivial (≤3 mm) residual peri-device leak on TEE. A standardized imaging protocol for assessment of Watchman device implantation incorporating pre-procedural MDCT and intra-procedural TEE, was associated with excellent procedural outcomes at a mean duration

  1. Estimating the Effective Sample Size of Tree Topologies from Bayesian Phylogenetic Analyses

    Science.gov (United States)

    Lanfear, Robert; Hua, Xia; Warren, Dan L.

    2016-01-01

    Bayesian phylogenetic analyses estimate posterior distributions of phylogenetic tree topologies and other parameters using Markov chain Monte Carlo (MCMC) methods. Before making inferences from these distributions, it is important to assess their adequacy. To this end, the effective sample size (ESS) estimates how many truly independent samples of a given parameter the output of the MCMC represents. The ESS of a parameter is frequently much lower than the number of samples taken from the MCMC because sequential samples from the chain can be non-independent due to autocorrelation. Typically, phylogeneticists use a rule of thumb that the ESS of all parameters should be greater than 200. However, we have no method to calculate an ESS of tree topology samples, despite the fact that the tree topology is often the parameter of primary interest and is almost always central to the estimation of other parameters. That is, we lack a method to determine whether we have adequately sampled one of the most important parameters in our analyses. In this study, we address this problem by developing methods to estimate the ESS for tree topologies. We combine these methods with two new diagnostic plots for assessing posterior samples of tree topologies, and compare their performance on simulated and empirical data sets. Combined, the methods we present provide new ways to assess the mixing and convergence of phylogenetic tree topologies in Bayesian MCMC analyses. PMID:27435794

  2. Effect size measures in a two-independent-samples case with nonnormal and nonhomogeneous data.

    Science.gov (United States)

    Li, Johnson Ching-Hong

    2016-12-01

    In psychological science, the "new statistics" refer to the new statistical practices that focus on effect size (ES) evaluation instead of conventional null-hypothesis significance testing (Cumming, Psychological Science, 25, 7-29, 2014). In a two-independent-samples scenario, Cohen's (1988) standardized mean difference (d) is the most popular ES, but its accuracy relies on two assumptions: normality and homogeneity of variances. Five other ESs-the unscaled robust d (d r * ; Hogarty & Kromrey, 2001), scaled robust d (d r ; Algina, Keselman, & Penfield, Psychological Methods, 10, 317-328, 2005), point-biserial correlation (r pb ; McGrath & Meyer, Psychological Methods, 11, 386-401, 2006), common-language ES (CL; Cliff, Psychological Bulletin, 114, 494-509, 1993), and nonparametric estimator for CL (A w ; Ruscio, Psychological Methods, 13, 19-30, 2008)-may be robust to violations of these assumptions, but no study has systematically evaluated their performance. Thus, in this simulation study the performance of these six ESs was examined across five factors: data distribution, sample, base rate, variance ratio, and sample size. The results showed that A w and d r were generally robust to these violations, and A w slightly outperformed d r . Implications for the use of A w and d r in real-world research are discussed.

  3. An automatic sample changer for gamma spectrometry

    International Nuclear Information System (INIS)

    Andrews, D.J.

    1984-01-01

    An automatic sample changer for gamma spectrometry is described which is designed for large-volume, low radioactivity environmental samples of various sizes up to maximum dimensions 100 mm diameter x 60 mm high. The sample changer is suitable for use with most existing gamma spectrometry systems which utilize GeLi or NaI detectors in vertical mode, in conjunction with a pulse height analyzer having auto-cycle and suitable data output facilities; it is linked to a Nuclear Data ND 6620 computer-based analysis system. (U.K.)

  4. Automatic particle-size analysis of HTGR nuclear fuel microspheres

    International Nuclear Information System (INIS)

    Mack, J.E.

    1977-01-01

    An automatic particle-size analyzer (PSA) has been developed at ORNL for measuring and counting samples of nuclear fuel microspheres in the diameter range of 300 to 1000 μm at rates in excess of 2000 particles per minute, requiring no sample preparation. A light blockage technique is used in conjunction with a particle singularizer. Each particle in the sample is sized, and the information is accumulated by a multi-channel pulse height analyzer. The data are then transferred automatically to a computer for calculation of mean diameter, standard deviation, kurtosis, and skewness of the distribution. Entering the sample weight and pre-coating data permits calculation of particle density and the mean coating thickness and density. Following this nondestructive analysis, the sample is collected and returned to the process line or used for further analysis. The device has potential as an on-line quality control device in processes dealing with spherical or near-spherical particles where rapid analysis is required for process control

  5. Size distribution, directional source contributions and pollution status of PM from Chengdu, China during a long-term sampling campaign.

    Science.gov (United States)

    Shi, Guo-Liang; Tian, Ying-Ze; Ma, Tong; Song, Dan-Lin; Zhou, Lai-Dong; Han, Bo; Feng, Yin-Chang; Russell, Armistead G

    2017-06-01

    Long-term and synchronous monitoring of PM 10 and PM 2.5 was conducted in Chengdu in China from 2007 to 2013. The levels, variations, compositions and size distributions were investigated. The sources were quantified by two-way and three-way receptor models (PMF2, ME2-2way and ME2-3way). Consistent results were found: the primary source categories contributed 63.4% (PMF2), 64.8% (ME2-2way) and 66.8% (ME2-3way) to PM 10 , and contributed 60.9% (PMF2), 65.5% (ME2-2way) and 61.0% (ME2-3way) to PM 2.5 . Secondary sources contributed 31.8% (PMF2), 32.9% (ME2-2way) and 31.7% (ME2-3way) to PM 10 , and 35.0% (PMF2), 33.8% (ME2-2way) and 36.0% (ME2-3way) to PM 2.5 . The size distribution of source categories was estimated better by the ME2-3way method. The three-way model can simultaneously consider chemical species, temporal variability and PM sizes, while a two-way model independently computes datasets of different sizes. A method called source directional apportionment (SDA) was employed to quantify the contributions from various directions for each source category. Crustal dust from east-north-east (ENE) contributed the highest to both PM 10 (12.7%) and PM 2.5 (9.7%) in Chengdu, followed by the crustal dust from south-east (SE) for PM 10 (9.8%) and secondary nitrate & secondary organic carbon from ENE for PM 2.5 (9.6%). Source contributions from different directions are associated with meteorological conditions, source locations and emission patterns during the sampling period. These findings and methods provide useful tools to better understand PM pollution status and to develop effective pollution control strategies. Copyright © 2016. Published by Elsevier B.V.

  6. Body Image and Body Type Preferences in St. Kitts, Caribbean: A Cross-Cultural Comparison with U.S. Samples regarding Attitudes towards Muscularity, Body Fat, and Breast Size

    Directory of Open Access Journals (Sweden)

    Peter B. Gray

    2012-07-01

    Full Text Available We investigated body image in St. Kitts, a Caribbean island where tourism, international media, and relatively high levels of body fat are common. Participants were men and women recruited from St. Kitts (n = 39 and, for comparison, U.S. samples from universities (n = 618 and the Internet (n = 438. Participants were shown computer generated images varying in apparent body fat level and muscularity or breast size and they indicated their body type preferences and attitudes. Overall, there were only modest differences in body type preferences between St. Kitts and the Internet sample, with the St. Kitts participants being somewhat more likely to value heavier women. Notably, however, men and women from St. Kitts were more likely to idealize smaller breasts than participants in the U.S. samples. Attitudes regarding muscularity were generally similar across samples. This study provides one of the few investigations of body preferences in the Caribbean.

  7. A novel approach for small sample size family-based association studies: sequential tests.

    Science.gov (United States)

    Ilk, Ozlem; Rajabli, Farid; Dungul, Dilay Ciglidag; Ozdag, Hilal; Ilk, Hakki Gokhan

    2011-08-01

    In this paper, we propose a sequential probability ratio test (SPRT) to overcome the problem of limited samples in studies related to complex genetic diseases. The results of this novel approach are compared with the ones obtained from the traditional transmission disequilibrium test (TDT) on simulated data. Although TDT classifies single-nucleotide polymorphisms (SNPs) to only two groups (SNPs associated with the disease and the others), SPRT has the flexibility of assigning SNPs to a third group, that is, those for which we do not have enough evidence and should keep sampling. It is shown that SPRT results in smaller ratios of false positives and negatives, as well as better accuracy and sensitivity values for classifying SNPs when compared with TDT. By using SPRT, data with small sample size become usable for an accurate association analysis.

  8. Sample Size and Statistical Conclusions from Tests of Fit to the Rasch Model According to the Rasch Unidimensional Measurement Model (Rumm) Program in Health Outcome Measurement.

    Science.gov (United States)

    Hagell, Peter; Westergren, Albert

    Sample size is a major factor in statistical null hypothesis testing, which is the basis for many approaches to testing Rasch model fit. Few sample size recommendations for testing fit to the Rasch model concern the Rasch Unidimensional Measurement Models (RUMM) software, which features chi-square and ANOVA/F-ratio based fit statistics, including Bonferroni and algebraic sample size adjustments. This paper explores the occurrence of Type I errors with RUMM fit statistics, and the effects of algebraic sample size adjustments. Data with simulated Rasch model fitting 25-item dichotomous scales and sample sizes ranging from N = 50 to N = 2500 were analysed with and without algebraically adjusted sample sizes. Results suggest the occurrence of Type I errors with N less then or equal to 500, and that Bonferroni correction as well as downward algebraic sample size adjustment are useful to avoid such errors, whereas upward adjustment of smaller samples falsely signal misfit. Our observations suggest that sample sizes around N = 250 to N = 500 may provide a good balance for the statistical interpretation of the RUMM fit statistics studied here with respect to Type I errors and under the assumption of Rasch model fit within the examined frame of reference (i.e., about 25 item parameters well targeted to the sample).

  9. A Bayesian approach for incorporating economic factors in sample size design for clinical trials of individual drugs and portfolios of drugs.

    Science.gov (United States)

    Patel, Nitin R; Ankolekar, Suresh

    2007-11-30

    Classical approaches to clinical trial design ignore economic factors that determine economic viability of a new drug. We address the choice of sample size in Phase III trials as a decision theory problem using a hybrid approach that takes a Bayesian view from the perspective of a drug company and a classical Neyman-Pearson view from the perspective of regulatory authorities. We incorporate relevant economic factors in the analysis to determine the optimal sample size to maximize the expected profit for the company. We extend the analysis to account for risk by using a 'satisficing' objective function that maximizes the chance of meeting a management-specified target level of profit. We extend the models for single drugs to a portfolio of clinical trials and optimize the sample sizes to maximize the expected profit subject to budget constraints. Further, we address the portfolio risk and optimize the sample sizes to maximize the probability of achieving a given target of expected profit.

  10. Computerization of radiology departmental management using the personal computer: application in medium sized hospital

    International Nuclear Information System (INIS)

    Ahn, Woo Hyun

    1992-01-01

    The author developed a computer program for use in registration, monthly statistics, printing of reports, data storage and retrieval in the Radiology department. This program has been used in the Department of Radiology, MoonHwa Hospital since November 1990. This program was written in FoxBASE language, consisted of two independent subprograms, one installed in a registration computer without a printer and another in a reporting computer with a printer. The subprograms were designed to link their data by floppy disk. Each computer's hard disk contained permanent files for retrieval and temporary files for data input. All permanent files were indexed on several keywords including the patient's identification data. 1. Registration was performed easily and rapidly. 2. A monthly statistic was obtained simply. 3. Retrieval of the results of previous radiologic studies, printing of report, storage and indexing of data were achieved automatically. This program had merits of simple operation, large storage capacity, rapid retrieval speed, relative low price, easy adjustment for other hospitals. Therefore this program is considered to be an economic substitute for computerization of radiology departmental management in medium sized hospitals

  11. Effect of sample moisture content on XRD-estimated cellulose crystallinity index and crystallite size

    Science.gov (United States)

    Umesh P. Agarwal; Sally A. Ralph; Carlos Baez; Richard S. Reiner; Steve P. Verrill

    2017-01-01

    Although X-ray diffraction (XRD) has been the most widely used technique to investigate crystallinity index (CrI) and crystallite size (L200) of cellulose materials, there are not many studies that have taken into account the role of sample moisture on these measurements. The present investigation focuses on a variety of celluloses and cellulose...

  12. Reproducibility of 5-HT2A receptor measurements and sample size estimations with [18F]altanserin PET using a bolus/infusion approach

    International Nuclear Information System (INIS)

    Haugboel, Steven; Pinborg, Lars H.; Arfan, Haroon M.; Froekjaer, Vibe M.; Svarer, Claus; Knudsen, Gitte M.; Madsen, Jacob; Dyrby, Tim B.

    2007-01-01

    To determine the reproducibility of measurements of brain 5-HT 2A receptors with an [ 18 F]altanserin PET bolus/infusion approach. Further, to estimate the sample size needed to detect regional differences between two groups and, finally, to evaluate how partial volume correction affects reproducibility and the required sample size. For assessment of the variability, six subjects were investigated with [ 18 F]altanserin PET twice, at an interval of less than 2 weeks. The sample size required to detect a 20% difference was estimated from [ 18 F]altanserin PET studies in 84 healthy subjects. Regions of interest were automatically delineated on co-registered MR and PET images. In cortical brain regions with a high density of 5-HT 2A receptors, the outcome parameter (binding potential, BP 1 ) showed high reproducibility, with a median difference between the two group measurements of 6% (range 5-12%), whereas in regions with a low receptor density, BP 1 reproducibility was lower, with a median difference of 17% (range 11-39%). Partial volume correction reduced the variability in the sample considerably. The sample size required to detect a 20% difference in brain regions with high receptor density is approximately 27, whereas for low receptor binding regions the required sample size is substantially higher. This study demonstrates that [ 18 F]altanserin PET with a bolus/infusion design has very low variability, particularly in larger brain regions with high 5-HT 2A receptor density. Moreover, partial volume correction considerably reduces the sample size required to detect regional changes between groups. (orig.)

  13. Large scale inference in the Infinite Relational Model: Gibbs sampling is not enough

    DEFF Research Database (Denmark)

    Albers, Kristoffer Jon; Moth, Andreas Leon Aagard; Mørup, Morten

    2013-01-01

    . We find that Gibbs sampling can be computationally scaled to handle millions of nodes and billions of links. Investigating the behavior of the Gibbs sampler for different sizes of networks we find that the mixing ability decreases drastically with the network size, clearly indicating a need...

  14. Efficient Sampling of the Structure of Crypto Generators' State Transition Graphs

    Science.gov (United States)

    Keller, Jörg

    Cryptographic generators, e.g. stream cipher generators like the A5/1 used in GSM networks or pseudo-random number generators, are widely used in cryptographic network protocols. Basically, they are finite state machines with deterministic transition functions. Their state transition graphs typically cannot be analyzed analytically, nor can they be explored completely because of their size which typically is at least n = 264. Yet, their structure, i.e. number and sizes of weakly connected components, is of interest because a structure deviating significantly from expected values for random graphs may form a distinguishing attack that indicates a weakness or backdoor. By sampling, one randomly chooses k nodes, derives their distribution onto connected components by graph exploration, and extrapolates these results to the complete graph. In known algorithms, the computational cost to determine the component for one randomly chosen node is up to O(√n), which severely restricts the sample size k. We present an algorithm where the computational cost to find the connected component for one randomly chosen node is O(1), so that a much larger sample size k can be analyzed in a given time. We report on the performance of a prototype implementation, and about preliminary analysis for several generators.

  15. Examination of weld defects by computed tomography

    Directory of Open Access Journals (Sweden)

    M. Jovanović

    2012-04-01

    Full Text Available Defects in metal arc gas (MAG welds made in S235JR low carbon steel of 6 mm thickness were examined. A sample containing lack of fusion (LOF and pores was examined by computed tomography – CT. The computed tomography examination was performed in order to define LOF size and position as well as dimensions and distribution of accompanying pores in the weld metal.

  16. Effects of sample size on estimation of rainfall extremes at high temperatures

    Science.gov (United States)

    Boessenkool, Berry; Bürger, Gerd; Heistermann, Maik

    2017-09-01

    High precipitation quantiles tend to rise with temperature, following the so-called Clausius-Clapeyron (CC) scaling. It is often reported that the CC-scaling relation breaks down and even reverts for very high temperatures. In our study, we investigate this reversal using observational climate data from 142 stations across Germany. One of the suggested meteorological explanations for the breakdown is limited moisture supply. Here we argue that, instead, it could simply originate from undersampling. As rainfall frequency generally decreases with higher temperatures, rainfall intensities as dictated by CC scaling are less likely to be recorded than for moderate temperatures. Empirical quantiles are conventionally estimated from order statistics via various forms of plotting position formulas. They have in common that their largest representable return period is given by the sample size. In small samples, high quantiles are underestimated accordingly. The small-sample effect is weaker, or disappears completely, when using parametric quantile estimates from a generalized Pareto distribution (GPD) fitted with L moments. For those, we obtain quantiles of rainfall intensities that continue to rise with temperature.

  17. Effects of sample size on estimation of rainfall extremes at high temperatures

    Directory of Open Access Journals (Sweden)

    B. Boessenkool

    2017-09-01

    Full Text Available High precipitation quantiles tend to rise with temperature, following the so-called Clausius–Clapeyron (CC scaling. It is often reported that the CC-scaling relation breaks down and even reverts for very high temperatures. In our study, we investigate this reversal using observational climate data from 142 stations across Germany. One of the suggested meteorological explanations for the breakdown is limited moisture supply. Here we argue that, instead, it could simply originate from undersampling. As rainfall frequency generally decreases with higher temperatures, rainfall intensities as dictated by CC scaling are less likely to be recorded than for moderate temperatures. Empirical quantiles are conventionally estimated from order statistics via various forms of plotting position formulas. They have in common that their largest representable return period is given by the sample size. In small samples, high quantiles are underestimated accordingly. The small-sample effect is weaker, or disappears completely, when using parametric quantile estimates from a generalized Pareto distribution (GPD fitted with L moments. For those, we obtain quantiles of rainfall intensities that continue to rise with temperature.

  18. Elemental analysis of size-fractionated particulate matter sampled in Goeteborg, Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Annemarie [Department of Chemistry, Atmospheric Science, Goeteborg University, SE-412 96 Goeteborg (Sweden)], E-mail: wagnera@chalmers.se; Boman, Johan [Department of Chemistry, Atmospheric Science, Goeteborg University, SE-412 96 Goeteborg (Sweden); Gatari, Michael J. [Institute of Nuclear Science and Technology, University of Nairobi, P.O. Box 30197-00100, Nairobi (Kenya)

    2008-12-15

    The aim of the study was to investigate the mass distribution of trace elements in aerosol samples collected in the urban area of Goeteborg, Sweden, with special focus on the impact of different air masses and anthropogenic activities. Three measurement campaigns were conducted during December 2006 and January 2007. A PIXE cascade impactor was used to collect particulate matter in 9 size fractions ranging from 16 to 0.06 {mu}m aerodynamic diameter. Polished quartz carriers were chosen as collection substrates for the subsequent direct analysis by TXRF. To investigate the sources of the analyzed air masses, backward trajectories were calculated. Our results showed that diurnal sampling was sufficient to investigate the mass distribution for Br, Ca, Cl, Cu, Fe, K, Sr and Zn, whereas a 5-day sampling period resulted in additional information on mass distribution for Cr and S. Unimodal mass distributions were found in the study area for the elements Ca, Cl, Fe and Zn, whereas the distributions for Br, Cu, Cr, K, Ni and S were bimodal, indicating high temperature processes as source of the submicron particle components. The measurement period including the New Year firework activities showed both an extensive increase in concentrations as well as a shift to the submicron range for K and Sr, elements that are typically found in fireworks. Further research is required to validate the quantification of trace elements directly collected on sample carriers.

  19. Elemental analysis of size-fractionated particulate matter sampled in Goeteborg, Sweden

    International Nuclear Information System (INIS)

    Wagner, Annemarie; Boman, Johan; Gatari, Michael J.

    2008-01-01

    The aim of the study was to investigate the mass distribution of trace elements in aerosol samples collected in the urban area of Goeteborg, Sweden, with special focus on the impact of different air masses and anthropogenic activities. Three measurement campaigns were conducted during December 2006 and January 2007. A PIXE cascade impactor was used to collect particulate matter in 9 size fractions ranging from 16 to 0.06 μm aerodynamic diameter. Polished quartz carriers were chosen as collection substrates for the subsequent direct analysis by TXRF. To investigate the sources of the analyzed air masses, backward trajectories were calculated. Our results showed that diurnal sampling was sufficient to investigate the mass distribution for Br, Ca, Cl, Cu, Fe, K, Sr and Zn, whereas a 5-day sampling period resulted in additional information on mass distribution for Cr and S. Unimodal mass distributions were found in the study area for the elements Ca, Cl, Fe and Zn, whereas the distributions for Br, Cu, Cr, K, Ni and S were bimodal, indicating high temperature processes as source of the submicron particle components. The measurement period including the New Year firework activities showed both an extensive increase in concentrations as well as a shift to the submicron range for K and Sr, elements that are typically found in fireworks. Further research is required to validate the quantification of trace elements directly collected on sample carriers

  20. Sampling and chemical analysis by TXRF of size-fractionated ambient aerosols and emissions

    International Nuclear Information System (INIS)

    John, A.C.; Kuhlbusch, T.A.J.; Fissan, H.; Schmidt, K.-G-; Schmidt, F.; Pfeffer, H.-U.; Gladtke, D.

    2000-01-01

    Results of recent epidemiological studies led to new European air quality standards which require the monitoring of particles with aerodynamic diameters ≤ 10 μm (PM 10) and ≤ 2.5 μm (PM 2.5) instead of TSP (total suspended particulate matter). As these ambient air limit values will be exceeded most likely at several locations in Europe, so-called 'action plans' have to be set up to reduce particle concentrations, which requires information about sources and processes of PMx aerosols. For chemical characterization of the aerosols, different samplers were used and total reflection x-ray fluorescence analysis (TXRF) was applied beside other methods (elemental and organic carbon analysis, ion chromatography, atomic absorption spectrometry). For TXRF analysis, a specially designed sampling unit was built where the particle size classes 10-2.5 μm and 2.5-1.0 μm were directly impacted on TXRF sample carriers. An electrostatic precipitator (ESP) was used as a back-up filter to collect particles <1 μm directly on a TXRF sample carrier. The sampling unit was calibrated in the laboratory and then used for field measurements to determine the elemental composition of the mentioned particle size fractions. One of the field campaigns was carried out at a measurement site in Duesseldorf, Germany, in November 1999. As the composition of the ambient aerosols may have been influenced by a large construction site directly in the vicinity of the station during the field campaign, not only the aerosol particles, but also construction material was sampled and analyzed by TXRF. As air quality is affected by natural and anthropogenic sources, the emissions of particles ≤ 10 μm and ≤ 2.5 μm, respectively, have to be determined to estimate their contributions to the so called coarse and fine particle modes of ambient air. Therefore, an in-stack particle sampling system was developed according to the new ambient air quality standards. This PM 10/PM 2.5 cascade impactor was

  1. Sample size planning for composite reliability coefficients: accuracy in parameter estimation via narrow confidence intervals.

    Science.gov (United States)

    Terry, Leann; Kelley, Ken

    2012-11-01

    Composite measures play an important role in psychology and related disciplines. Composite measures almost always have error. Correspondingly, it is important to understand the reliability of the scores from any particular composite measure. However, the point estimates of the reliability of composite measures are fallible and thus all such point estimates should be accompanied by a confidence interval. When confidence intervals are wide, there is much uncertainty in the population value of the reliability coefficient. Given the importance of reporting confidence intervals for estimates of reliability, coupled with the undesirability of wide confidence intervals, we develop methods that allow researchers to plan sample size in order to obtain narrow confidence intervals for population reliability coefficients. We first discuss composite reliability coefficients and then provide a discussion on confidence interval formation for the corresponding population value. Using the accuracy in parameter estimation approach, we develop two methods to obtain accurate estimates of reliability by planning sample size. The first method provides a way to plan sample size so that the expected confidence interval width for the population reliability coefficient is sufficiently narrow. The second method ensures that the confidence interval width will be sufficiently narrow with some desired degree of assurance (e.g., 99% assurance that the 95% confidence interval for the population reliability coefficient will be less than W units wide). The effectiveness of our methods was verified with Monte Carlo simulation studies. We demonstrate how to easily implement the methods with easy-to-use and freely available software. ©2011 The British Psychological Society.

  2. SMPBS: Web server for computing biomolecular electrostatics using finite element solvers of size modified Poisson-Boltzmann equation.

    Science.gov (United States)

    Xie, Yang; Ying, Jinyong; Xie, Dexuan

    2017-03-30

    SMPBS (Size Modified Poisson-Boltzmann Solvers) is a web server for computing biomolecular electrostatics using finite element solvers of the size modified Poisson-Boltzmann equation (SMPBE). SMPBE not only reflects ionic size effects but also includes the classic Poisson-Boltzmann equation (PBE) as a special case. Thus, its web server is expected to have a broader range of applications than a PBE web server. SMPBS is designed with a dynamic, mobile-friendly user interface, and features easily accessible help text, asynchronous data submission, and an interactive, hardware-accelerated molecular visualization viewer based on the 3Dmol.js library. In particular, the viewer allows computed electrostatics to be directly mapped onto an irregular triangular mesh of a molecular surface. Due to this functionality and the fast SMPBE finite element solvers, the web server is very efficient in the calculation and visualization of electrostatics. In addition, SMPBE is reconstructed using a new objective electrostatic free energy, clearly showing that the electrostatics and ionic concentrations predicted by SMPBE are optimal in the sense of minimizing the objective electrostatic free energy. SMPBS is available at the URL: smpbs.math.uwm.edu © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Required sample size for monitoring stand dynamics in strict forest reserves: a case study

    Science.gov (United States)

    Diego Van Den Meersschaut; Bart De Cuyper; Kris Vandekerkhove; Noel Lust

    2000-01-01

    Stand dynamics in European strict forest reserves are commonly monitored using inventory densities of 5 to 15 percent of the total surface. The assumption that these densities guarantee a representative image of certain parameters is critically analyzed in a case study for the parameters basal area and stem number. The required sample sizes for different accuracy and...

  4. A Generalized Least Squares Regression Approach for Computing Effect Sizes in Single-Case Research: Application Examples

    Science.gov (United States)

    Maggin, Daniel M.; Swaminathan, Hariharan; Rogers, Helen J.; O'Keeffe, Breda V.; Sugai, George; Horner, Robert H.

    2011-01-01

    A new method for deriving effect sizes from single-case designs is proposed. The strategy is applicable to small-sample time-series data with autoregressive errors. The method uses Generalized Least Squares (GLS) to model the autocorrelation of the data and estimate regression parameters to produce an effect size that represents the magnitude of…

  5. Hybrid algorithm of ensemble transform and importance sampling for assimilation of non-Gaussian observations

    Directory of Open Access Journals (Sweden)

    Shin'ya Nakano

    2014-05-01

    Full Text Available A hybrid algorithm that combines the ensemble transform Kalman filter (ETKF and the importance sampling approach is proposed. Since the ETKF assumes a linear Gaussian observation model, the estimate obtained by the ETKF can be biased in cases with nonlinear or non-Gaussian observations. The particle filter (PF is based on the importance sampling technique, and is applicable to problems with nonlinear or non-Gaussian observations. However, the PF usually requires an unrealistically large sample size in order to achieve a good estimation, and thus it is computationally prohibitive. In the proposed hybrid algorithm, we obtain a proposal distribution similar to the posterior distribution by using the ETKF. A large number of samples are then drawn from the proposal distribution, and these samples are weighted to approximate the posterior distribution according to the importance sampling principle. Since the importance sampling provides an estimate of the probability density function (PDF without assuming linearity or Gaussianity, we can resolve the bias due to the nonlinear or non-Gaussian observations. Finally, in the next forecast step, we reduce the sample size to achieve computational efficiency based on the Gaussian assumption, while we use a relatively large number of samples in the importance sampling in order to consider the non-Gaussian features of the posterior PDF. The use of the ETKF is also beneficial in terms of the computational simplicity of generating a number of random samples from the proposal distribution and in weighting each of the samples. The proposed algorithm is not necessarily effective in case that the ensemble is located distant from the true state. However, monitoring the effective sample size and tuning the factor for covariance inflation could resolve this problem. In this paper, the proposed hybrid algorithm is introduced and its performance is evaluated through experiments with non-Gaussian observations.

  6. Reproducibility of R-fMRI metrics on the impact of different strategies for multiple comparison correction and sample sizes.

    Science.gov (United States)

    Chen, Xiao; Lu, Bin; Yan, Chao-Gan

    2018-01-01

    Concerns regarding reproducibility of resting-state functional magnetic resonance imaging (R-fMRI) findings have been raised. Little is known about how to operationally define R-fMRI reproducibility and to what extent it is affected by multiple comparison correction strategies and sample size. We comprehensively assessed two aspects of reproducibility, test-retest reliability and replicability, on widely used R-fMRI metrics in both between-subject contrasts of sex differences and within-subject comparisons of eyes-open and eyes-closed (EOEC) conditions. We noted permutation test with Threshold-Free Cluster Enhancement (TFCE), a strict multiple comparison correction strategy, reached the best balance between family-wise error rate (under 5%) and test-retest reliability/replicability (e.g., 0.68 for test-retest reliability and 0.25 for replicability of amplitude of low-frequency fluctuations (ALFF) for between-subject sex differences, 0.49 for replicability of ALFF for within-subject EOEC differences). Although R-fMRI indices attained moderate reliabilities, they replicated poorly in distinct datasets (replicability < 0.3 for between-subject sex differences, < 0.5 for within-subject EOEC differences). By randomly drawing different sample sizes from a single site, we found reliability, sensitivity and positive predictive value (PPV) rose as sample size increased. Small sample sizes (e.g., < 80 [40 per group]) not only minimized power (sensitivity < 2%), but also decreased the likelihood that significant results reflect "true" effects (PPV < 0.26) in sex differences. Our findings have implications for how to select multiple comparison correction strategies and highlight the importance of sufficiently large sample sizes in R-fMRI studies to enhance reproducibility. Hum Brain Mapp 39:300-318, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion An activity that is still in progress is computing for the heavy-ion program. The heavy-ion events are collected without zero suppression, so the event size is much large at roughly 11 MB per event of RAW. The central collisions are more complex and...

  8. Terahertz Computed Tomography of NASA Thermal Protection System Materials

    Science.gov (United States)

    Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.

    2011-01-01

    A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

  9. Effect of Mechanical Impact Energy on the Sorption and Diffusion of Moisture in Reinforced Polymer Composite Samples on Variation of Their Sizes

    Science.gov (United States)

    Startsev, V. O.; Il'ichev, A. V.

    2018-05-01

    The effect of mechanical impact energy on the sorption and diffusion of moisture in polymer composite samples on variation of their sizes was investigated. Square samples, with sides of 40, 60, 80, and 100 mm, made of a KMKU-2m-120.E0,1 carbon-fiber and KMKS-2m.120.T10 glass-fiber plastics with different resistances to calibrated impacts, were compared. Impact loading diagrams of the samples in relation to their sizes and impact energy were analyzed. It is shown that the moisture saturation and moisture diffusion coefficient of the impact-damaged materials can be modeled by Fick's second law with account of impact energy and sample sizes.

  10. Right Size Determining the Staff Necessary to Sustain Simulation and Computing Capabilities for Nuclear Security

    Energy Technology Data Exchange (ETDEWEB)

    Nikkel, Daniel J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Meisner, Robert [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2010-09-10

    The Advanced Simulation and Computing Campaign, herein referred to as the ASC Program, is a core element of the science-based Stockpile Stewardship Program (SSP), which enables assessment, certification, and maintenance of the safety, security, and reliability of the U.S. nuclear stockpile without the need to resume nuclear testing. The use of advanced parallel computing has transitioned from proof-of-principle to become a critical element for assessing and certifying the stockpile. As the initiative phase of the ASC Program came to an end in the mid-2000s, the National Nuclear Security Administration redirected resources to other urgent priorities, and resulting staff reductions in ASC occurred without the benefit of analysis of the impact on modern stockpile stewardship that is dependent on these new simulation capabilities. Consequently, in mid-2008 the ASC Program management commissioned a study to estimate the essential size and balance needed to sustain advanced simulation as a core component of stockpile stewardship. The ASC Program requires a minimum base staff size of 930 (which includes the number of staff necessary to maintain critical technical disciplines as well as to execute required programmatic tasks) to sustain its essential ongoing role in stockpile stewardship.

  11. Computed Tomography Status

    Science.gov (United States)

    Hansche, B. D.

    1983-01-01

    Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.

  12. Maximum inflation of the type 1 error rate when sample size and allocation rate are adapted in a pre-planned interim look.

    Science.gov (United States)

    Graf, Alexandra C; Bauer, Peter

    2011-06-30

    We calculate the maximum type 1 error rate of the pre-planned conventional fixed sample size test for comparing the means of independent normal distributions (with common known variance) which can be yielded when sample size and allocation rate to the treatment arms can be modified in an interim analysis. Thereby it is assumed that the experimenter fully exploits knowledge of the unblinded interim estimates of the treatment effects in order to maximize the conditional type 1 error rate. The 'worst-case' strategies require knowledge of the unknown common treatment effect under the null hypothesis. Although this is a rather hypothetical scenario it may be approached in practice when using a standard control treatment for which precise estimates are available from historical data. The maximum inflation of the type 1 error rate is substantially larger than derived by Proschan and Hunsberger (Biometrics 1995; 51:1315-1324) for design modifications applying balanced samples before and after the interim analysis. Corresponding upper limits for the maximum type 1 error rate are calculated for a number of situations arising from practical considerations (e.g. restricting the maximum sample size, not allowing sample size to decrease, allowing only increase in the sample size in the experimental treatment). The application is discussed for a motivating example. Copyright © 2011 John Wiley & Sons, Ltd.

  13. Day and night variation in chemical composition and toxicological responses of size segregated urban air PM samples in a high air pollution situation

    Science.gov (United States)

    Jalava, P. I.; Wang, Q.; Kuuspalo, K.; Ruusunen, J.; Hao, L.; Fang, D.; Väisänen, O.; Ruuskanen, A.; Sippula, O.; Happo, M. S.; Uski, O.; Kasurinen, S.; Torvela, T.; Koponen, H.; Lehtinen, K. E. J.; Komppula, M.; Gu, C.; Jokiniemi, J.; Hirvonen, M.-R.

    2015-11-01

    Urban air particulate pollution is a known cause for adverse human health effects worldwide. China has encountered air quality problems in recent years due to rapid industrialization. Toxicological effects induced by particulate air pollution vary with particle sizes and season. However, it is not known how distinctively different photochemical activity and different emission sources during the day and the night affect the chemical composition of the PM size ranges and subsequently how it is reflected to the toxicological properties of the PM exposures. The particulate matter (PM) samples were collected in four different size ranges (PM10-2.5; PM2.5-1; PM1-0.2 and PM0.2) with a high volume cascade impactor. The PM samples were extracted with methanol, dried and thereafter used in the chemical and toxicological analyses. RAW264.7 macrophages were exposed to the particulate samples in four different doses for 24 h. Cytotoxicity, inflammatory parameters, cell cycle and genotoxicity were measured after exposure of the cells to particulate samples. Particles were characterized for their chemical composition, including ions, element and PAH compounds, and transmission electron microscopy (TEM) was used to take images of the PM samples. Chemical composition and the induced toxicological responses of the size segregated PM samples showed considerable size dependent differences as well as day to night variation. The PM10-2.5 and the PM0.2 samples had the highest inflammatory potency among the size ranges. Instead, almost all the PM samples were equally cytotoxic and only minor differences were seen in genotoxicity and cell cycle effects. Overall, the PM0.2 samples had the highest toxic potential among the different size ranges in many parameters. PAH compounds in the samples and were generally more abundant during the night than the day, indicating possible photo-oxidation of the PAH compounds due to solar radiation. This was reflected to different toxicity in the PM

  14. Extension of Latin hypercube samples with correlated variables

    Energy Technology Data Exchange (ETDEWEB)

    Sallaberry, C.J. [Sandia National Laboratories, Department 6784, MS 0776, Albuquerque, NM 87185-0776 (United States); Helton, J.C. [Department of Mathematics and Statistics, Arizona State University, Tempe, AZ 85287-1804 (United States)], E-mail: jchelto@sandia.gov; Hora, S.C. [University of Hawaii at Hilo, Hilo, HI 96720-4091 (United States)

    2008-07-15

    A procedure for extending the size of a Latin hypercube sample (LHS) with rank correlated variables is described and illustrated. The extension procedure starts with an LHS of size m and associated rank correlation matrix C and constructs a new LHS of size 2m that contains the elements of the original LHS and has a rank correlation matrix that is close to the original rank correlation matrix C. The procedure is intended for use in conjunction with uncertainty and sensitivity analysis of computationally demanding models in which it is important to make efficient use of a necessarily limited number of model evaluations.

  15. Extension of Latin hypercube samples with correlated variables

    International Nuclear Information System (INIS)

    Sallaberry, C.J.; Helton, J.C.; Hora, S.C.

    2008-01-01

    A procedure for extending the size of a Latin hypercube sample (LHS) with rank correlated variables is described and illustrated. The extension procedure starts with an LHS of size m and associated rank correlation matrix C and constructs a new LHS of size 2m that contains the elements of the original LHS and has a rank correlation matrix that is close to the original rank correlation matrix C. The procedure is intended for use in conjunction with uncertainty and sensitivity analysis of computationally demanding models in which it is important to make efficient use of a necessarily limited number of model evaluations

  16. Extension of latin hypercube samples with correlated variables.

    Energy Technology Data Exchange (ETDEWEB)

    Hora, Stephen Curtis (University of Hawaii at Hilo, HI); Helton, Jon Craig (Arizona State University, Tempe, AZ); Sallaberry, Cedric J. PhD. (.; .)

    2006-11-01

    A procedure for extending the size of a Latin hypercube sample (LHS) with rank correlated variables is described and illustrated. The extension procedure starts with an LHS of size m and associated rank correlation matrix C and constructs a new LHS of size 2m that contains the elements of the original LHS and has a rank correlation matrix that is close to the original rank correlation matrix C. The procedure is intended for use in conjunction with uncertainty and sensitivity analysis of computationally demanding models in which it is important to make efficient use of a necessarily limited number of model evaluations.

  17. Understanding the cluster randomised crossover design: a graphical illustraton of the components of variation and a sample size tutorial.

    Science.gov (United States)

    Arnup, Sarah J; McKenzie, Joanne E; Hemming, Karla; Pilcher, David; Forbes, Andrew B

    2017-08-15

    In a cluster randomised crossover (CRXO) design, a sequence of interventions is assigned to a group, or 'cluster' of individuals. Each cluster receives each intervention in a separate period of time, forming 'cluster-periods'. Sample size calculations for CRXO trials need to account for both the cluster randomisation and crossover aspects of the design. Formulae are available for the two-period, two-intervention, cross-sectional CRXO design, however implementation of these formulae is known to be suboptimal. The aims of this tutorial are to illustrate the intuition behind the design; and provide guidance on performing sample size calculations. Graphical illustrations are used to describe the effect of the cluster randomisation and crossover aspects of the design on the correlation between individual responses in a CRXO trial. Sample size calculations for binary and continuous outcomes are illustrated using parameters estimated from the Australia and New Zealand Intensive Care Society - Adult Patient Database (ANZICS-APD) for patient mortality and length(s) of stay (LOS). The similarity between individual responses in a CRXO trial can be understood in terms of three components of variation: variation in cluster mean response; variation in the cluster-period mean response; and variation between individual responses within a cluster-period; or equivalently in terms of the correlation between individual responses in the same cluster-period (within-cluster within-period correlation, WPC), and between individual responses in the same cluster, but in different periods (within-cluster between-period correlation, BPC). The BPC lies between zero and the WPC. When the WPC and BPC are equal the precision gained by crossover aspect of the CRXO design equals the precision lost by cluster randomisation. When the BPC is zero there is no advantage in a CRXO over a parallel-group cluster randomised trial. Sample size calculations illustrate that small changes in the specification of

  18. Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans.

    Science.gov (United States)

    Shokri, Abbas; Ramezani, Leila; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed

    2018-03-01

    This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes ( P <.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

  19. A regression-based differential expression detection algorithm for microarray studies with ultra-low sample size.

    Directory of Open Access Journals (Sweden)

    Daniel Vasiliu

    Full Text Available Global gene expression analysis using microarrays and, more recently, RNA-seq, has allowed investigators to understand biological processes at a system level. However, the identification of differentially expressed genes in experiments with small sample size, high dimensionality, and high variance remains challenging, limiting the usability of these tens of thousands of publicly available, and possibly many more unpublished, gene expression datasets. We propose a novel variable selection algorithm for ultra-low-n microarray studies using generalized linear model-based variable selection with a penalized binomial regression algorithm called penalized Euclidean distance (PED. Our method uses PED to build a classifier on the experimental data to rank genes by importance. In place of cross-validation, which is required by most similar methods but not reliable for experiments with small sample size, we use a simulation-based approach to additively build a list of differentially expressed genes from the rank-ordered list. Our simulation-based approach maintains a low false discovery rate while maximizing the number of differentially expressed genes identified, a feature critical for downstream pathway analysis. We apply our method to microarray data from an experiment perturbing the Notch signaling pathway in Xenopus laevis embryos. This dataset was chosen because it showed very little differential expression according to limma, a powerful and widely-used method for microarray analysis. Our method was able to detect a significant number of differentially expressed genes in this dataset and suggest future directions for investigation. Our method is easily adaptable for analysis of data from RNA-seq and other global expression experiments with low sample size and high dimensionality.

  20. Quantification of errors in ordinal outcome scales using shannon entropy: effect on sample size calculations.

    Science.gov (United States)

    Mandava, Pitchaiah; Krumpelman, Chase S; Shah, Jharna N; White, Donna L; Kent, Thomas A

    2013-01-01

    Clinical trial outcomes often involve an ordinal scale of subjective functional assessments but the optimal way to quantify results is not clear. In stroke, the most commonly used scale, the modified Rankin Score (mRS), a range of scores ("Shift") is proposed as superior to dichotomization because of greater information transfer. The influence of known uncertainties in mRS assessment has not been quantified. We hypothesized that errors caused by uncertainties could be quantified by applying information theory. Using Shannon's model, we quantified errors of the "Shift" compared to dichotomized outcomes using published distributions of mRS uncertainties and applied this model to clinical trials. We identified 35 randomized stroke trials that met inclusion criteria. Each trial's mRS distribution was multiplied with the noise distribution from published mRS inter-rater variability to generate an error percentage for "shift" and dichotomized cut-points. For the SAINT I neuroprotectant trial, considered positive by "shift" mRS while the larger follow-up SAINT II trial was negative, we recalculated sample size required if classification uncertainty was taken into account. Considering the full mRS range, error rate was 26.1%±5.31 (Mean±SD). Error rates were lower for all dichotomizations tested using cut-points (e.g. mRS 1; 6.8%±2.89; overall pdecrease in reliability. The resultant errors need to be considered since sample size may otherwise be underestimated. In principle, we have outlined an approach to error estimation for any condition in which there are uncertainties in outcome assessment. We provide the user with programs to calculate and incorporate errors into sample size estimation.

  1. Fruit size and sampling sites affect on dormancy, viability and germination of teak (Tectona grandis L.) seeds

    International Nuclear Information System (INIS)

    Akram, M.; Aftab, F.

    2016-01-01

    In the present study, fruits (drupes) were collected from Changa Manga Forest Plus Trees (CMF-PT), Changa Manga Forest Teak Stand (CMF-TS) and Punjab University Botanical Gardens (PUBG) and categorized into very large (= 17 mm dia.), large (12-16 mm dia.), medium (9-11 mm dia.) or small (6-8 mm dia.) fruit size grades. Fresh water as well as mechanical scarification and stratification were tested for breaking seed dormancy. Viability status of seeds was estimated by cutting test, X-rays and In vitro seed germination. Out of 2595 fruits from CMF-PT, 500 fruits were of very large grade. This fruit category also had highest individual fruit weight (0.58 g) with more number of 4-seeded fruits (5.29 percent) and fair germination potential (35.32 percent). Generally, most of the fruits were 1-seeded irrespective of size grades and sampling sites. Fresh water scarification had strong effect on germination (44.30 percent) as compared to mechanical scarification and cold stratification after 40 days of sowing. Similarly, sampling sites and fruit size grades also had significant influence on germination. Highest germination (82.33 percent) was obtained on MS (Murashige and Skoog) agar-solidified medium as compared to Woody Plant Medium (WPM) (69.22 percent). Seedlings from all the media were transferred to ex vitro conditions in the greenhouse and achieved highest survival (28.6 percent) from seedlings previously raised on MS agar-solidified medium after 40 days. There was an association between the studied parameters of teak seeds and the sampling sites and fruit size. (author)

  2. Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size

    International Nuclear Information System (INIS)

    Davila, Jesse A.; Kransdorf, Mark J.; Duffy, Gavan P.

    2006-01-01

    The purpose of our study was to assess the accuracy of a computer-assisted templating in the surgical planning of patients undergoing total hip arthroplasty utilizing EndoMap software (Siemans AG, Medical Solutions, Erlangen, Germany). Endomap Software is an electronic program that uses DICOM images to analyze standard anteroposterior radiographs for determination of optimal prosthesis component size. We retrospectively reviewed the preoperative radiographs of 36 patients undergoing uncomplicated primary total hip arthroplasty, utilizing EndoMap software, Version VA20. DICOM anteroposterior radiographs were analyzed using standard manufacturer supplied electronic templates to determine acetabular and femoral component sizes. No additional clinical information was reviewed. Acetabular and femoral component sizes were assessed by an orthopedic surgeon and two radiologists. Mean and estimated component size was compared with component size as documented in operative reports. The mean estimated acetabular component size was 53 mm (range 48-60 mm), 1 mm larger than the mean implanted size of 52 mm (range 48-62 mm). Thirty-one of 36 acetabular component sizes (86%) were accurate within one size. The mean calculated femoral component size was 4 (range 2-7), 1 size smaller than the actual mean component size of 5 (range 2-9). Twenty-six of 36 femoral component sizes (72%) were accurate within one size, and accurate within two sizes in all but four cases (94%). EndoMap Software predicted femoral component size well, with 72% within one component size of that used, and 94% within two sizes. Acetabular component size was predicted slightly better with 86% within one component size and 94% within two component sizes. (orig.)

  3. Sample-size resonance, ferromagnetic resonance and magneto-permittivity resonance in multiferroic nano-BiFeO3/paraffin composites at room temperature

    International Nuclear Information System (INIS)

    Wang, Lei; Li, Zhenyu; Jiang, Jia; An, Taiyu; Qin, Hongwei; Hu, Jifan

    2017-01-01

    In the present work, we demonstrate that ferromagnetic resonance and magneto-permittivity resonance can be observed in appropriate microwave frequencies at room temperature for multiferroic nano-BiFeO 3 /paraffin composite sample with an appropriate sample-thickness (such as 2 mm). Ferromagnetic resonance originates from the room-temperature weak ferromagnetism of nano-BiFeO 3 . The observed magneto-permittivity resonance in multiferroic nano-BiFeO 3 is connected with the dynamic magnetoelectric coupling through Dzyaloshinskii–Moriya (DM) magnetoelectric interaction or the combination of magnetostriction and piezoelectric effects. In addition, we experimentally observed the resonance of negative imaginary permeability for nano BiFeO 3 /paraffin toroidal samples with longer sample thicknesses D=3.7 and 4.9 mm. Such resonance of negative imaginary permeability belongs to sample-size resonance. - Highlights: • Nano-BiFeO 3 /paraffin composite shows a ferromagnetic resonance. • Nano-BiFeO 3 /paraffin composite shows a magneto-permittivity resonance. • Resonance of negative imaginary permeability in BiFeO 3 is a sample-size resonance. • Nano-BiFeO 3 /paraffin composite with large thickness shows a sample-size resonance.

  4. The Effect of Sterilization on Size and Shape of Fat Globules in Model Processed Cheese Samples

    Directory of Open Access Journals (Sweden)

    B. Tremlová

    2006-01-01

    Full Text Available Model cheese samples from 4 independent productions were heat sterilized (117 °C, 20 minutes after the melting process and packing with an aim to prolong their durability. The objective of the study was to assess changes in the size and shape of fat globules due to heat sterilization by using image analysis methods. The study included a selection of suitable methods of preparation mounts, taking microphotographs and making overlays for automatic processing of photographs by image analyser, ascertaining parameters to determine the size and shape of fat globules and statistical analysis of results obtained. The results of the experiment suggest that changes in shape of fat globules due to heat sterilization are not unequivocal. We found that the size of fat globules was significantly increased (p < 0.01 due to heat sterilization (117 °C, 20 min, and the shares of small fat globules (up to 500 μm2, or 100 μm2 in the samples of heat sterilized processed cheese were decreased. The results imply that the image analysis method is very useful when assessing the effect of technological process on the quality of processed cheese quality.

  5. Sampling bee communities using pan traps: alternative methods increase sample size

    Science.gov (United States)

    Monitoring of the status of bee populations and inventories of bee faunas require systematic sampling. Efficiency and ease of implementation has encouraged the use of pan traps to sample bees. Efforts to find an optimal standardized sampling method for pan traps have focused on pan trap color. Th...

  6. Measurements of Plutonium and Americium in Soil Samples from Project 57 using the Suspended Soil Particle Sizing System (SSPSS)

    International Nuclear Information System (INIS)

    John L. Bowen; Rowena Gonzalez; David S. Shafer

    2001-01-01

    As part of the preliminary site characterization conducted for Project 57, soils samples were collected for separation into several size-fractions using the Suspended Soil Particle Sizing System (SSPSS). Soil samples were collected specifically for separation by the SSPSS at three general locations in the deposited Project 57 plume, the projected radioactivity of which ranged from 100 to 600 pCi/g. The primary purpose in focusing on samples with this level of activity is that it would represent anticipated residual soil contamination levels at the site after corrective actions are completed. Consequently, the results of the SSPSS analysis can contribute to dose calculation and corrective action-level determinations for future land-use scenarios at the site

  7. Computer scientist looks at reliability computations

    International Nuclear Information System (INIS)

    Rosenthal, A.

    1975-01-01

    Results from the theory of computational complexity are applied to reliability computations on fault trees and networks. A well known class of problems which almost certainly have no fast solution algorithms is presented. It is shown that even approximately computing the reliability of many systems is difficult enough to be in this class. In the face of this result, which indicates that for general systems the computation time will be exponential in the size of the system, decomposition techniques which can greatly reduce the effective size of a wide variety of realistic systems are explored

  8. Influence of secular trends and sample size on reference equations for lung function tests.

    Science.gov (United States)

    Quanjer, P H; Stocks, J; Cole, T J; Hall, G L; Stanojevic, S

    2011-03-01

    The aim of our study was to determine the contribution of secular trends and sample size to lung function reference equations, and establish the number of local subjects required to validate published reference values. 30 spirometry datasets collected between 1978 and 2009 provided data on healthy, white subjects: 19,291 males and 23,741 females aged 2.5-95 yrs. The best fit for forced expiratory volume in 1 s (FEV(1)), forced vital capacity (FVC) and FEV(1)/FVC as functions of age, height and sex were derived from the entire dataset using GAMLSS. Mean z-scores were calculated for individual datasets to determine inter-centre differences. This was repeated by subdividing one large dataset (3,683 males and 4,759 females) into 36 smaller subsets (comprising 18-227 individuals) to preclude differences due to population/technique. No secular trends were observed and differences between datasets comprising >1,000 subjects were small (maximum difference in FEV(1) and FVC from overall mean: 0.30- -0.22 z-scores). Subdividing one large dataset into smaller subsets reproduced the above sample size-related differences and revealed that at least 150 males and 150 females would be necessary to validate reference values to avoid spurious differences due to sampling error. Use of local controls to validate reference equations will rarely be practical due to the numbers required. Reference equations derived from large or collated datasets are recommended.

  9. VASCOMP 2. The V/STOL aircraft sizing and performance computer program. Volume 6: User's manual, revision 3

    Science.gov (United States)

    Schoen, A. H.; Rosenstein, H.; Stanzione, K.; Wisniewski, J. S.

    1980-01-01

    This report describes the use of the V/STOL Aircraft Sizing and Performance Computer Program (VASCOMP II). The program is useful in performing aircraft parametric studies in a quick and cost efficient manner. Problem formulation and data development were performed by the Boeing Vertol Company and reflects the present preliminary design technology. The computer program, written in FORTRAN IV, has a broad range of input parameters, to enable investigation of a wide variety of aircraft. User oriented features of the program include minimized input requirements, diagnostic capabilities, and various options for program flexibility.

  10. On the Importance of Accounting for Competing Risks in Pediatric Brain Cancer: II. Regression Modeling and Sample Size

    International Nuclear Information System (INIS)

    Tai, Bee-Choo; Grundy, Richard; Machin, David

    2011-01-01

    Purpose: To accurately model the cumulative need for radiotherapy in trials designed to delay or avoid irradiation among children with malignant brain tumor, it is crucial to account for competing events and evaluate how each contributes to the timing of irradiation. An appropriate choice of statistical model is also important for adequate determination of sample size. Methods and Materials: We describe the statistical modeling of competing events (A, radiotherapy after progression; B, no radiotherapy after progression; and C, elective radiotherapy) using proportional cause-specific and subdistribution hazard functions. The procedures of sample size estimation based on each method are outlined. These are illustrated by use of data comparing children with ependymoma and other malignant brain tumors. The results from these two approaches are compared. Results: The cause-specific hazard analysis showed a reduction in hazards among infants with ependymoma for all event types, including Event A (adjusted cause-specific hazard ratio, 0.76; 95% confidence interval, 0.45-1.28). Conversely, the subdistribution hazard analysis suggested an increase in hazard for Event A (adjusted subdistribution hazard ratio, 1.35; 95% confidence interval, 0.80-2.30), but the reduction in hazards for Events B and C remained. Analysis based on subdistribution hazard requires a larger sample size than the cause-specific hazard approach. Conclusions: Notable differences in effect estimates and anticipated sample size were observed between methods when the main event showed a beneficial effect whereas the competing events showed an adverse effect on the cumulative incidence. The subdistribution hazard is the most appropriate for modeling treatment when its effects on both the main and competing events are of interest.

  11. Effects of LiDAR point density, sampling size and height threshold on estimation accuracy of crop biophysical parameters.

    Science.gov (United States)

    Luo, Shezhou; Chen, Jing M; Wang, Cheng; Xi, Xiaohuan; Zeng, Hongcheng; Peng, Dailiang; Li, Dong

    2016-05-30

    Vegetation leaf area index (LAI), height, and aboveground biomass are key biophysical parameters. Corn is an important and globally distributed crop, and reliable estimations of these parameters are essential for corn yield forecasting, health monitoring and ecosystem modeling. Light Detection and Ranging (LiDAR) is considered an effective technology for estimating vegetation biophysical parameters. However, the estimation accuracies of these parameters are affected by multiple factors. In this study, we first estimated corn LAI, height and biomass (R2 = 0.80, 0.874 and 0.838, respectively) using the original LiDAR data (7.32 points/m2), and the results showed that LiDAR data could accurately estimate these biophysical parameters. Second, comprehensive research was conducted on the effects of LiDAR point density, sampling size and height threshold on the estimation accuracy of LAI, height and biomass. Our findings indicated that LiDAR point density had an important effect on the estimation accuracy for vegetation biophysical parameters, however, high point density did not always produce highly accurate estimates, and reduced point density could deliver reasonable estimation results. Furthermore, the results showed that sampling size and height threshold were additional key factors that affect the estimation accuracy of biophysical parameters. Therefore, the optimal sampling size and the height threshold should be determined to improve the estimation accuracy of biophysical parameters. Our results also implied that a higher LiDAR point density, larger sampling size and height threshold were required to obtain accurate corn LAI estimation when compared with height and biomass estimations. In general, our results provide valuable guidance for LiDAR data acquisition and estimation of vegetation biophysical parameters using LiDAR data.

  12. Two to five repeated measurements per patient reduced the required sample size considerably in a randomized clinical trial for patients with inflammatory rheumatic diseases

    Directory of Open Access Journals (Sweden)

    Smedslund Geir

    2013-02-01

    Full Text Available Abstract Background Patient reported outcomes are accepted as important outcome measures in rheumatology. The fluctuating symptoms in patients with rheumatic diseases have serious implications for sample size in clinical trials. We estimated the effects of measuring the outcome 1-5 times on the sample size required in a two-armed trial. Findings In a randomized controlled trial that evaluated the effects of a mindfulness-based group intervention for patients with inflammatory arthritis (n=71, the outcome variables Numerical Rating Scales (NRS (pain, fatigue, disease activity, self-care ability, and emotional wellbeing and General Health Questionnaire (GHQ-20 were measured five times before and after the intervention. For each variable we calculated the necessary sample sizes for obtaining 80% power (α=.05 for one up to five measurements. Two, three, and four measures reduced the required sample sizes by 15%, 21%, and 24%, respectively. With three (and five measures, the required sample size per group was reduced from 56 to 39 (32 for the GHQ-20, from 71 to 60 (55 for pain, 96 to 71 (73 for fatigue, 57 to 51 (48 for disease activity, 59 to 44 (45 for self-care, and 47 to 37 (33 for emotional wellbeing. Conclusions Measuring the outcomes five times rather than once reduced the necessary sample size by an average of 27%. When planning a study, researchers should carefully compare the advantages and disadvantages of increasing sample size versus employing three to five repeated measurements in order to obtain the required statistical power.

  13. tscvh R Package: Computational of the two samples test on microarray-sequencing data

    Science.gov (United States)

    Fajriyah, Rohmatul; Rosadi, Dedi

    2017-12-01

    We present a new R package, a tscvh (two samples cross-variance homogeneity), as we called it. This package is a software of the cross-variance statistical test which has been proposed and introduced by Fajriyah ([3] and [4]), based on the cross-variance concept. The test can be used as an alternative test for the significance difference between two means when sample size is small, the situation which is usually appeared in the bioinformatics research. Based on its statistical distribution, the p-value can be also provided. The package is built under a homogeneity of variance between samples.

  14. Sampling considerations when analyzing micrometric-sized particles in a liquid jet using laser induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Faye, C.B.; Amodeo, T.; Fréjafon, E. [Institut National de l' Environnement Industriel et des Risques (INERIS/DRC/CARA/NOVA), Parc Technologique Alata, BP 2, 60550 Verneuil-En-Halatte (France); Delepine-Gilon, N. [Institut des Sciences Analytiques, 5 rue de la Doua, 69100 Villeurbanne (France); Dutouquet, C., E-mail: christophe.dutouquet@ineris.fr [Institut National de l' Environnement Industriel et des Risques (INERIS/DRC/CARA/NOVA), Parc Technologique Alata, BP 2, 60550 Verneuil-En-Halatte (France)

    2014-01-01

    Pollution of water is a matter of concern all over the earth. Particles are known to play an important role in the transportation of pollutants in this medium. In addition, the emergence of new materials such as NOAA (Nano-Objects, their Aggregates and their Agglomerates) emphasizes the need to develop adapted instruments for their detection. Surveillance of pollutants in particulate form in waste waters in industries involved in nanoparticle manufacturing and processing is a telling example of possible applications of such instrumental development. The LIBS (laser-induced breakdown spectroscopy) technique coupled with the liquid jet as sampling mode for suspensions was deemed as a potential candidate for on-line and real time monitoring. With the final aim in view to obtain the best detection limits, the interaction of nanosecond laser pulses with the liquid jet was examined. The evolution of the volume sampled by laser pulses was estimated as a function of the laser energy applying conditional analysis when analyzing a suspension of micrometric-sized particles of borosilicate glass. An estimation of the sampled depth was made. Along with the estimation of the sampled volume, the evolution of the SNR (signal to noise ratio) as a function of the laser energy was investigated as well. Eventually, the laser energy and the corresponding fluence optimizing both the sampling volume and the SNR were determined. The obtained results highlight intrinsic limitations of the liquid jet sampling mode when using 532 nm nanosecond laser pulses with suspensions. - Highlights: • Micrometric-sized particles in suspensions are analyzed using LIBS and a liquid jet. • The evolution of the sampling volume is estimated as a function of laser energy. • The sampling volume happens to saturate beyond a certain laser fluence. • Its value was found much lower than the beam diameter times the jet thickness. • Particles proved not to be entirely vaporized.

  15. Using the Superpopulation Model for Imputations and Variance Computation in Survey Sampling

    Directory of Open Access Journals (Sweden)

    Petr Novák

    2012-03-01

    Full Text Available This study is aimed at variance computation techniques for estimates of population characteristics based on survey sampling and imputation. We use the superpopulation regression model, which means that the target variable values for each statistical unit are treated as random realizations of a linear regression model with weighted variance. We focus on regression models with one auxiliary variable and no intercept, which have many applications and straightforward interpretation in business statistics. Furthermore, we deal with caseswhere the estimates are not independent and thus the covariance must be computed. We also consider chained regression models with auxiliary variables as random variables instead of constants.

  16. Prognostic significance of tumor size of small lung adenocarcinomas evaluated with mediastinal window settings on computed tomography.

    Directory of Open Access Journals (Sweden)

    Yukinori Sakao

    Full Text Available BACKGROUND: We aimed to clarify that the size of the lung adenocarcinoma evaluated using mediastinal window on computed tomography is an important and useful modality for predicting invasiveness, lymph node metastasis and prognosis in small adenocarcinoma. METHODS: We evaluated 176 patients with small lung adenocarcinomas (diameter, 1-3 cm who underwent standard surgical resection. Tumours were examined using computed tomography with thin section conditions (1.25 mm thick on high-resolution computed tomography with tumour dimensions evaluated under two settings: lung window and mediastinal window. We also determined the patient age, gender, preoperative nodal status, tumour size, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and pathological status (lymphatic vessel, vascular vessel or pleural invasion. Recurrence-free survival was used for prognosis. RESULTS: Lung window, mediastinal window, tumour disappearance ratio and preoperative nodal status were significant predictive factors for recurrence-free survival in univariate analyses. Areas under the receiver operator curves for recurrence were 0.76, 0.73 and 0.65 for mediastinal window, tumour disappearance ratio and lung window, respectively. Lung window, mediastinal window, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and preoperative nodal status were significant predictive factors for lymph node metastasis in univariate analyses; areas under the receiver operator curves were 0.61, 0.76, 0.72 and 0.66, for lung window, mediastinal window, tumour disappearance ratio and preoperative serum carcinoembryonic antigen levels, respectively. Lung window, mediastinal window, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and preoperative nodal status were significant factors for lymphatic vessel, vascular vessel or pleural invasion in univariate analyses; areas under the receiver operator curves were 0

  17. Prognostic Significance of Tumor Size of Small Lung Adenocarcinomas Evaluated with Mediastinal Window Settings on Computed Tomography

    Science.gov (United States)

    Sakao, Yukinori; Kuroda, Hiroaki; Mun, Mingyon; Uehara, Hirofumi; Motoi, Noriko; Ishikawa, Yuichi; Nakagawa, Ken; Okumura, Sakae

    2014-01-01

    Background We aimed to clarify that the size of the lung adenocarcinoma evaluated using mediastinal window on computed tomography is an important and useful modality for predicting invasiveness, lymph node metastasis and prognosis in small adenocarcinoma. Methods We evaluated 176 patients with small lung adenocarcinomas (diameter, 1–3 cm) who underwent standard surgical resection. Tumours were examined using computed tomography with thin section conditions (1.25 mm thick on high-resolution computed tomography) with tumour dimensions evaluated under two settings: lung window and mediastinal window. We also determined the patient age, gender, preoperative nodal status, tumour size, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and pathological status (lymphatic vessel, vascular vessel or pleural invasion). Recurrence-free survival was used for prognosis. Results Lung window, mediastinal window, tumour disappearance ratio and preoperative nodal status were significant predictive factors for recurrence-free survival in univariate analyses. Areas under the receiver operator curves for recurrence were 0.76, 0.73 and 0.65 for mediastinal window, tumour disappearance ratio and lung window, respectively. Lung window, mediastinal window, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and preoperative nodal status were significant predictive factors for lymph node metastasis in univariate analyses; areas under the receiver operator curves were 0.61, 0.76, 0.72 and 0.66, for lung window, mediastinal window, tumour disappearance ratio and preoperative serum carcinoembryonic antigen levels, respectively. Lung window, mediastinal window, tumour disappearance ratio, preoperative serum carcinoembryonic antigen levels and preoperative nodal status were significant factors for lymphatic vessel, vascular vessel or pleural invasion in univariate analyses; areas under the receiver operator curves were 0.60, 0.81, 0

  18. TableSim--A program for analysis of small-sample categorical data.

    Science.gov (United States)

    David J. Rugg

    2003-01-01

    Documents a computer program for calculating correct P-values of 1-way and 2-way tables when sample sizes are small. The program is written in Fortran 90; the executable code runs in 32-bit Microsoft-- command line environments.

  19. Droplet Size-Aware and Error-Correcting Sample Preparation Using Micro-Electrode-Dot-Array Digital Microfluidic Biochips.

    Science.gov (United States)

    Li, Zipeng; Lai, Kelvin Yi-Tse; Chakrabarty, Krishnendu; Ho, Tsung-Yi; Lee, Chen-Yi

    2017-12-01

    Sample preparation in digital microfluidics refers to the generation of droplets with target concentrations for on-chip biochemical applications. In recent years, digital microfluidic biochips (DMFBs) have been adopted as a platform for sample preparation. However, there remain two major problems associated with sample preparation on a conventional DMFB. First, only a (1:1) mixing/splitting model can be used, leading to an increase in the number of fluidic operations required for sample preparation. Second, only a limited number of sensors can be integrated on a conventional DMFB; as a result, the latency for error detection during sample preparation is significant. To overcome these drawbacks, we adopt a next generation DMFB platform, referred to as micro-electrode-dot-array (MEDA), for sample preparation. We propose the first sample-preparation method that exploits the MEDA-specific advantages of fine-grained control of droplet sizes and real-time droplet sensing. Experimental demonstration using a fabricated MEDA biochip and simulation results highlight the effectiveness of the proposed sample-preparation method.

  20. A behavioral Bayes method to determine the sample size of a clinical trial considering efficacy and safety.

    Science.gov (United States)

    Kikuchi, Takashi; Gittins, John

    2009-08-15

    It is necessary for the calculation of sample size to achieve the best balance between the cost of a clinical trial and the possible benefits from a new treatment. Gittins and Pezeshk developed an innovative (behavioral Bayes) approach, which assumes that the number of users is an increasing function of the difference in performance between the new treatment and the standard treatment. The better a new treatment, the more the number of patients who want to switch to it. The optimal sample size is calculated in this framework. This BeBay approach takes account of three decision-makers, a pharmaceutical company, the health authority and medical advisers. Kikuchi, Pezeshk and Gittins generalized this approach by introducing a logistic benefit function, and by extending to the more usual unpaired case, and with unknown variance. The expected net benefit in this model is based on the efficacy of the new drug but does not take account of the incidence of adverse reactions. The present paper extends the model to include the costs of treating adverse reactions and focuses on societal cost-effectiveness as the criterion for determining sample size. The main application is likely to be to phase III clinical trials, for which the primary outcome is to compare the costs and benefits of a new drug with a standard drug in relation to national health-care. Copyright 2009 John Wiley & Sons, Ltd.

  1. Improved orientation sampling for indexing diffraction patterns of polycrystalline materials

    DEFF Research Database (Denmark)

    Larsen, Peter Mahler; Schmidt, Søren

    2017-01-01

    to that of optimally distributing points on a four‐dimensional sphere. In doing so, the number of orientation samples needed to achieve a desired indexing accuracy is significantly reduced. Orientation sets at a range of sizes are generated in this way for all Laue groups and are made available online for easy use.......Orientation mapping is a widely used technique for revealing the microstructure of a polycrystalline sample. The crystalline orientation at each point in the sample is determined by analysis of the diffraction pattern, a process known as pattern indexing. A recent development in pattern indexing...... in the presence of noise, it has very high computational requirements. In this article, the computational burden is reduced by developing a method for nearly optimal sampling of orientations. By using the quaternion representation of orientations, it is shown that the optimal sampling problem is equivalent...

  2. Comparison of the accuracy of 3-dimensional cone-beam computed tomography and micro-computed tomography reconstructions by using different voxel sizes.

    Science.gov (United States)

    Maret, Delphine; Peters, Ove A; Galibourg, Antoine; Dumoncel, Jean; Esclassan, Rémi; Kahn, Jean-Luc; Sixou, Michel; Telmon, Norbert

    2014-09-01

    Cone-beam computed tomography (CBCT) data are, in principle, metrically exact. However, clinicians need to consider the precision of measurements of dental morphology as well as other hard tissue structures. CBCT spatial resolution, and thus image reconstruction quality, is restricted by the acquisition voxel size. The aim of this study was to assess geometric discrepancies among 3-dimensional CBCT reconstructions relative to the micro-CT reference. A total of 37 permanent teeth from 9 mandibles were scanned with CBCT 9500 and 9000 3D and micro-CT. After semiautomatic segmentation, reconstructions were obtained from CBCT acquisitions (voxel sizes 76, 200, and 300 μm) and from micro-CT (voxel size 41 μm). All reconstructions were positioned in the same plane by image registration. The topography of the geometric discrepancies was displayed by using a color map allowing the maximum differences to be located. The maximum differences were mainly found at the cervical margins and on the cusp tips or incisal edges. Geometric reconstruction discrepancies were significant at 300-μm resolution (P = .01, Wilcoxon test). To study hard tissue morphology, CBCT acquisitions require voxel sizes smaller than 300 μm. This experimental study will have to be complemented by studies in vivo that consider the conditions of clinical practice. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Magneto dynamic study of small size superconductors

    International Nuclear Information System (INIS)

    Mamsurova, L.G.; Pigal'skij, K.S.; Sakun, V.P.

    1996-01-01

    Magnetic field dependencies of magnetic permeability in fine grained YBaCuO samples of grain size D approx λ are investigated. The hysteresis of an oscillatory part of the magnetic permeability is evaluated for a system of loosely bound grains. Numerical calculations of vortex structures and appropriate μ v values for a superconducting plate of thickness d approx λ are made for cases of thermodynamical equilibrium and the existence. The computational results qualitatively agree with the experiment

  4. Elaboration of austenitic stainless steel samples with bimodal grain size distributions and investigation of their mechanical behavior

    Science.gov (United States)

    Flipon, B.; de la Cruz, L. Garcia; Hug, E.; Keller, C.; Barbe, F.

    2017-10-01

    Samples of 316L austenitic stainless steel with bimodal grain size distributions are elaborated using two distinct routes. The first one is based on powder metallurgy using spark plasma sintering of two powders with different particle sizes. The second route applies the reverse-annealing method: it consists in inducing martensitic phase transformation by plastic strain and further annealing in order to obtain two austenitic grain populations with different sizes. Microstructural analy ses reveal that both methods are suitable to generate significative grain size contrast and to control this contrast according to the elaboration conditions. Mechanical properties under tension are then characterized for different grain size distributions. Crystal plasticity finite element modelling is further applied in a configuration of bimodal distribution to analyse the role played by coarse grains within a matrix of fine grains, considering not only their volume fraction but also their spatial arrangement.

  5. Path-integral computation of superfluid densities

    International Nuclear Information System (INIS)

    Pollock, E.L.; Ceperley, D.M.

    1987-01-01

    The normal and superfluid densities are defined by the response of a liquid to sample boundary motion. The free-energy change due to uniform boundary motion can be calculated by path-integral methods from the distribution of the winding number of the paths around a periodic cell. This provides a conceptually and computationally simple way of calculating the superfluid density for any Bose system. The linear-response formulation relates the superfluid density to the momentum-density correlation function, which has a short-ranged part related to the normal density and, in the case of a superfluid, a long-ranged part whose strength is proportional to the superfluid density. These facts are discussed in the context of path-integral computations and demonstrated for liquid 4 He along the saturated vapor-pressure curve. Below the experimental superfluid transition temperature the computed superfluid fractions agree with the experimental values to within the statistical uncertainties of a few percent in the computations. The computed transition is broadened by finite-sample-size effects

  6. The N-Pact Factor: Evaluating the Quality of Empirical Journals with Respect to Sample Size and Statistical Power

    Science.gov (United States)

    Fraley, R. Chris; Vazire, Simine

    2014-01-01

    The authors evaluate the quality of research reported in major journals in social-personality psychology by ranking those journals with respect to their N-pact Factors (NF)—the statistical power of the empirical studies they publish to detect typical effect sizes. Power is a particularly important attribute for evaluating research quality because, relative to studies that have low power, studies that have high power are more likely to (a) to provide accurate estimates of effects, (b) to produce literatures with low false positive rates, and (c) to lead to replicable findings. The authors show that the average sample size in social-personality research is 104 and that the power to detect the typical effect size in the field is approximately 50%. Moreover, they show that there is considerable variation among journals in sample sizes and power of the studies they publish, with some journals consistently publishing higher power studies than others. The authors hope that these rankings will be of use to authors who are choosing where to submit their best work, provide hiring and promotion committees with a superior way of quantifying journal quality, and encourage competition among journals to improve their NF rankings. PMID:25296159

  7. The Effects of Test Length and Sample Size on Item Parameters in Item Response Theory

    Science.gov (United States)

    Sahin, Alper; Anil, Duygu

    2017-01-01

    This study investigates the effects of sample size and test length on item-parameter estimation in test development utilizing three unidimensional dichotomous models of item response theory (IRT). For this purpose, a real language test comprised of 50 items was administered to 6,288 students. Data from this test was used to obtain data sets of…

  8. Scaling strength distributions in quasi-brittle materials from micro-to macro-scales: A computational approach to modeling Nature-inspired structural ceramics

    International Nuclear Information System (INIS)

    Genet, Martin; Couegnat, Guillaume; Tomsia, Antoni P.; Ritchie, Robert O.

    2014-01-01

    This paper presents an approach to predict the strength distribution of quasi-brittle materials across multiple length-scales, with emphasis on Nature-inspired ceramic structures. It permits the computation of the failure probability of any structure under any mechanical load, solely based on considerations of the microstructure and its failure properties by naturally incorporating the statistical and size-dependent aspects of failure. We overcome the intrinsic limitations of single periodic unit-based approaches by computing the successive failures of the material components and associated stress redistributions on arbitrary numbers of periodic units. For large size samples, the microscopic cells are replaced by a homogenized continuum with equivalent stochastic and damaged constitutive behavior. After establishing the predictive capabilities of the method, and illustrating its potential relevance to several engineering problems, we employ it in the study of the shape and scaling of strength distributions across differing length-scales for a particular quasi-brittle system. We find that the strength distributions display a Weibull form for samples of size approaching the periodic unit; however, these distributions become closer to normal with further increase in sample size before finally reverting to a Weibull form for macroscopic sized samples. In terms of scaling, we find that the weakest link scaling applies only to microscopic, and not macroscopic scale, samples. These findings are discussed in relation to failure patterns computed at different size-scales. (authors)

  9. Influence of pH, Temperature and Sample Size on Natural and Enforced Syneresis of Precipitated Silica

    Directory of Open Access Journals (Sweden)

    Sebastian Wilhelm

    2015-12-01

    Full Text Available The production of silica is performed by mixing an inorganic, silicate-based precursor and an acid. Monomeric silicic acid forms and polymerizes to amorphous silica particles. Both further polymerization and agglomeration of the particles lead to a gel network. Since polymerization continues after gelation, the gel network consolidates. This rather slow process is known as “natural syneresis” and strongly influences the product properties (e.g., agglomerate size, porosity or internal surface. “Enforced syneresis” is the superposition of natural syneresis with a mechanical, external force. Enforced syneresis may be used either for analytical or preparative purposes. Hereby, two open key aspects are of particular interest. On the one hand, the question arises whether natural and enforced syneresis are analogous processes with respect to their dependence on the process parameters: pH, temperature and sample size. On the other hand, a method is desirable that allows for correlating natural and enforced syneresis behavior. We can show that the pH-, temperature- and sample size-dependency of natural and enforced syneresis are indeed analogous. It is possible to predict natural syneresis using a correlative model. We found that our model predicts maximum volume shrinkages between 19% and 30% in comparison to measured values of 20% for natural syneresis.

  10. Optimum sample length for estimating anchovy size distribution and the proportion of juveniles per fishing set for the Peruvian purse-seine fleet

    Directory of Open Access Journals (Sweden)

    Rocío Joo

    2017-04-01

    Full Text Available The length distribution of catches represents a fundamental source of information for estimating growth and spatio-temporal dynamics of cohorts. The length distribution of caught is estimated based on samples of catched individuals. This work studies the optimum sample size of individuals at each fishing set in order to obtain a representative sample of the length and the proportion of juveniles in the fishing set. For that matter, we use anchovy (Engraulis ringens length data from different fishing sets recorded by observers at-sea from the On-board Observers Program from the Peruvian Marine Research Institute. Finally, we propose an optimum sample size for obtaining robust size and juvenile estimations. Though the application of this work corresponds to the anchovy fishery, the procedure can be applied to any fishery, either for on board or inland biometric measurements.

  11. Computed Tomographic Measurement of Splenic Size in

    International Nuclear Information System (INIS)

    Sung, Nak Kwan; Woo, Seong Ku; Ko, Young Tae; Kim, Soon Young

    2010-01-01

    Authors analyzed 72 cases of abdominal computed tomography of Korean adults who didn't have any medical reasons to believe the spleen was abnormal. The following criteria were measured with multiple transverse scanning of the entire length of spleen (height, breadth, thickness) relationship with fixed midline structure, the spine (the shortest distance from midline to medial edge of spleen, the longest distance from anterior margin of vertebral body to anterior tip of spleen). The results were as follows: 1. The average size in adult was 8.0±1.5cm in height, 8.6±1.2cm in breadth and 3.4±0.6cm in thickness; in adult female, 7.8±1.1cm, 8.4±1.0cm and 3.4±0.6cm, respectively; total average, 7.9±1.3cm, 8.5±1.1cm and 3.4±0.6cm, respectively. No remarkable difference was noted between both sexes and age groups. 2. The shortest distance from midline to medial edge of spleen was 4.1±1.1cm in male, 3.6±1.0cm in female and total average of 3.9±1.1cm. There was remarkable difference between both sexes (P<0.005) but not between age groups. 3. The longest distance from anterior margin of vertebral body to anterior adge of spleen was 2.3±1.7cm in male, 2.0±1.4cm in female and total average of 2.2±1.6cm. No remarkable difference was seen between both sexes and age groups.

  12. (I Can’t Get No) Saturation: A simulation and guidelines for sample sizes in qualitative research

    NARCIS (Netherlands)

    van Rijnsoever, Frank J.

    2017-01-01

    I explore the sample size in qualitative research that is required to reach theoretical saturation. I conceptualize a population as consisting of sub-populations that contain different types of information sources that hold a number of codes. Theoretical saturation is reached after all the codes in

  13. Magnetic response and critical current properties of mesoscopic-size YBCO superconducting samples

    International Nuclear Information System (INIS)

    Lisboa-Filho, P N; Deimling, C V; Ortiz, W A

    2010-01-01

    In this contribution superconducting specimens of YBa 2 Cu 3 O 7-δ were synthesized by a modified polymeric precursor method, yielding a ceramic powder with particles of mesoscopic-size. Samples of this powder were then pressed into pellets and sintered under different conditions. The critical current density was analyzed by isothermal AC-susceptibility measurements as a function of the excitation field, as well as with isothermal DC-magnetization runs at different values of the applied field. Relevant features of the magnetic response could be associated to the microstructure of the specimens and, in particular, to the superconducting intra- and intergranular critical current properties.

  14. Magnetic response and critical current properties of mesoscopic-size YBCO superconducting samples

    Energy Technology Data Exchange (ETDEWEB)

    Lisboa-Filho, P N [UNESP - Universidade Estadual Paulista, Grupo de Materiais Avancados, Departamento de Fisica, Bauru (Brazil); Deimling, C V; Ortiz, W A, E-mail: plisboa@fc.unesp.b [Grupo de Supercondutividade e Magnetismo, Departamento de Fisica, Universidade Federal de Sao Carlos, Sao Carlos (Brazil)

    2010-01-15

    In this contribution superconducting specimens of YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} were synthesized by a modified polymeric precursor method, yielding a ceramic powder with particles of mesoscopic-size. Samples of this powder were then pressed into pellets and sintered under different conditions. The critical current density was analyzed by isothermal AC-susceptibility measurements as a function of the excitation field, as well as with isothermal DC-magnetization runs at different values of the applied field. Relevant features of the magnetic response could be associated to the microstructure of the specimens and, in particular, to the superconducting intra- and intergranular critical current properties.

  15. Sample-size resonance, ferromagnetic resonance and magneto-permittivity resonance in multiferroic nano-BiFeO{sub 3}/paraffin composites at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lei; Li, Zhenyu; Jiang, Jia; An, Taiyu; Qin, Hongwei; Hu, Jifan, E-mail: hujf@sdu.edu.cn

    2017-01-01

    In the present work, we demonstrate that ferromagnetic resonance and magneto-permittivity resonance can be observed in appropriate microwave frequencies at room temperature for multiferroic nano-BiFeO{sub 3}/paraffin composite sample with an appropriate sample-thickness (such as 2 mm). Ferromagnetic resonance originates from the room-temperature weak ferromagnetism of nano-BiFeO{sub 3}. The observed magneto-permittivity resonance in multiferroic nano-BiFeO{sub 3} is connected with the dynamic magnetoelectric coupling through Dzyaloshinskii–Moriya (DM) magnetoelectric interaction or the combination of magnetostriction and piezoelectric effects. In addition, we experimentally observed the resonance of negative imaginary permeability for nano BiFeO{sub 3}/paraffin toroidal samples with longer sample thicknesses D=3.7 and 4.9 mm. Such resonance of negative imaginary permeability belongs to sample-size resonance. - Highlights: • Nano-BiFeO{sub 3}/paraffin composite shows a ferromagnetic resonance. • Nano-BiFeO{sub 3}/paraffin composite shows a magneto-permittivity resonance. • Resonance of negative imaginary permeability in BiFeO{sub 3} is a sample-size resonance. • Nano-BiFeO{sub 3}/paraffin composite with large thickness shows a sample-size resonance.

  16. Computing the Free Energy Barriers for Less by Sampling with a Coarse Reference Potential while Retaining Accuracy of the Target Fine Model.

    Science.gov (United States)

    Plotnikov, Nikolay V

    2014-08-12

    Proposed in this contribution is a protocol for calculating fine-physics (e.g., ab initio QM/MM) free-energy surfaces at a high level of accuracy locally (e.g., only at reactants and at the transition state for computing the activation barrier) from targeted fine-physics sampling and extensive exploratory coarse-physics sampling. The full free-energy surface is still computed but at a lower level of accuracy from coarse-physics sampling. The method is analytically derived in terms of the umbrella sampling and the free-energy perturbation methods which are combined with the thermodynamic cycle and the targeted sampling strategy of the paradynamics approach. The algorithm starts by computing low-accuracy fine-physics free-energy surfaces from the coarse-physics sampling in order to identify the reaction path and to select regions for targeted sampling. Thus, the algorithm does not rely on the coarse-physics minimum free-energy reaction path. Next, segments of high-accuracy free-energy surface are computed locally at selected regions from the targeted fine-physics sampling and are positioned relative to the coarse-physics free-energy shifts. The positioning is done by averaging the free-energy perturbations computed with multistep linear response approximation method. This method is analytically shown to provide results of the thermodynamic integration and the free-energy interpolation methods, while being extremely simple in implementation. Incorporating the metadynamics sampling to the algorithm is also briefly outlined. The application is demonstrated by calculating the B3LYP//6-31G*/MM free-energy barrier for an enzymatic reaction using a semiempirical PM6/MM reference potential. These modifications allow computing the activation free energies at a significantly reduced computational cost but at the same level of accuracy compared to computing full potential of mean force.

  17. Reducing sample size by combining superiority and non-inferiority for two primary endpoints in the Social Fitness study.

    Science.gov (United States)

    Donkers, Hanneke; Graff, Maud; Vernooij-Dassen, Myrra; Nijhuis-van der Sanden, Maria; Teerenstra, Steven

    2017-01-01

    In randomized controlled trials, two endpoints may be necessary to capture the multidimensional concept of the intervention and the objectives of the study adequately. We show how to calculate sample size when defining success of a trial by combinations of superiority and/or non-inferiority aims for the endpoints. The randomized controlled trial design of the Social Fitness study uses two primary endpoints, which can be combined into five different scenarios for defining success of the trial. We show how to calculate power and sample size for each scenario and compare these for different settings of power of each endpoint and correlation between them. Compared to a single primary endpoint, using two primary endpoints often gives more power when success is defined as: improvement in one of the two endpoints and no deterioration in the other. This also gives better power than when success is defined as: improvement in one prespecified endpoint and no deterioration in the remaining endpoint. When two primary endpoints are equally important, but a positive effect in both simultaneously is not per se required, the objective of having one superior and the other (at least) non-inferior could make sense and reduce sample size. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Predictive equations for lung volumes from computed tomography for size matching in pulmonary transplantation.

    Science.gov (United States)

    Konheim, Jeremy A; Kon, Zachary N; Pasrija, Chetan; Luo, Qingyang; Sanchez, Pablo G; Garcia, Jose P; Griffith, Bartley P; Jeudy, Jean

    2016-04-01

    Size matching for lung transplantation is widely accomplished using height comparisons between donors and recipients. This gross approximation allows for wide variation in lung size and, potentially, size mismatch. Three-dimensional computed tomography (3D-CT) volumetry comparisons could offer more accurate size matching. Although recipient CT scans are universally available, donor CT scans are rarely performed. Therefore, predicted donor lung volumes could be used for comparison to measured recipient lung volumes, but no such predictive equations exist. We aimed to use 3D-CT volumetry measurements from a normal patient population to generate equations for predicted total lung volume (pTLV), predicted right lung volume (pRLV), and predicted left lung volume (pLLV), for size-matching purposes. Chest CT scans of 400 normal patients were retrospectively evaluated. 3D-CT volumetry was performed to measure total lung volume, right lung volume, and left lung volume of each patient, and predictive equations were generated. The fitted model was tested in a separate group of 100 patients. The model was externally validated by comparison of total lung volume with total lung capacity from pulmonary function tests in a subset of those patients. Age, gender, height, and race were independent predictors of lung volume. In the test group, there were strong linear correlations between predicted and actual lung volumes measured by 3D-CT volumetry for pTLV (r = 0.72), pRLV (r = 0.72), and pLLV (r = 0.69). A strong linear correlation was also observed when comparing pTLV and total lung capacity (r = 0.82). We successfully created a predictive model for pTLV, pRLV, and pLLV. These may serve as reference standards and predict donor lung volume for size matching in lung transplantation. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  19. Effect of the grain size of the soil on the measured activity and variation in activity in surface and subsurface soil samples

    International Nuclear Information System (INIS)

    Sulaiti, H.A.; Rega, P.H.; Bradley, D.; Dahan, N.A.; Mugren, K.A.; Dosari, M.A.

    2014-01-01

    Correlation between grain size and activity concentrations of soils and concentrations of various radionuclides in surface and subsurface soils has been measured for samples taken in the State of Qatar by gamma-spectroscopy using a high purity germanium detector. From the obtained gamma-ray spectra, the activity concentrations of the 238U (226Ra) and /sup 232/ Th (/sup 228/ Ac) natural decay series, the long-lived naturally occurring radionuclide 40 K and the fission product radionuclide 137CS have been determined. Gamma dose rate, radium equivalent, radiation hazard index and annual effective dose rates have also been estimated from these data. In order to observe the effect of grain size on the radioactivity of soil, three grain sizes were used i.e., smaller than 0.5 mm; smaller than 1 mm and greater than 0.5 mm; and smaller than 2 mm and greater than 1 mm. The weighted activity concentrations of the 238U series nuclides in 0.5-2 mm grain size of sample numbers was found to vary from 2.5:f:0.2 to 28.5+-0.5 Bq/kg, whereas, the weighted activity concentration of 4 degree K varied from 21+-4 to 188+-10 Bq/kg. The weighted activity concentrations of 238U series and 4 degree K have been found to be higher in the finest grain size. However, for the 232Th series, the activity concentrations in the 1-2 mm grain size of one sample were found to be higher than in the 0.5-1 mm grain size. In the study of surface and subsurface soil samples, the activity concentration levels of 238 U series have been found to range from 15.9+-0.3 to 24.1+-0.9 Bq/kg, in the surface soil samples (0-5 cm) and 14.5+-0.3 to 23.6+-0.5 Bq/kg in the subsurface soil samples (5-25 cm). The activity concentrations of 232Th series have been found to lie in the range 5.7+-0.2 to 13.7+-0.5 Bq/kg, in the surface soil samples (0-5 cm)and 4.1+-0.2 to 15.6+-0.3 Bq/kg in the subsurface soil samples (5-25 cm). The activity concentrations of 4 degree K were in the range 150+-8 to 290+-17 Bq/kg, in the surface

  20. Assessment of soil sample quality used for density evaluations through computed tomography

    International Nuclear Information System (INIS)

    Pires, Luiz F.; Arthur, Robson C.J.; Bacchi, Osny O.S.

    2005-01-01

    There are several methods to measure soil bulk density (ρ s ) like the paraffin sealed clod (PS), the volumetric ring (VR), the computed tomography (CT), and the neutron-gamma surface gauge (SG). In order to evaluate by a non-destructive way the possible modifications in soil structure caused by sampling for the PS and VR methods of ρ s evaluation we proposed to use the gamma ray CT method. A first generation tomograph was used having a 241 Am source and a 3 in x 3 in NaI(Tl) scintillation crystal detector coupled to a photomultiplier tube. Results confirm the effect of soil sampler devices on the structure of soil samples, and that the compaction caused during sampling causes significant alterations of soil bulk density. Through the use of CT it was possible to determine the level of compaction and to make a detailed analysis of the soil bulk density distribution within the soil sample. (author)

  1. Computer simulation of high-energy recoils in FCC metals: cascade shapes and sizes

    International Nuclear Information System (INIS)

    Heinisch, H.L.

    1981-01-01

    Displacement cascades in copper generated by primary knock-on atoms with energies from 1 keV to 500 keV were produced with the computer code MARLOWE. The sizes and other features of the point defect distributions were measured as a function of energy. In the energy range from 30 keV to 50 keV there is a transition from compact single damage regions to chains of generally closely-spaced, but distinct multiple damage regions. The average spacing between multiple damage regions remains constant with energy. Only a small fraction of the recoils from fusion neutrons is expected to produce widely separated subcascades

  2. Effects of Sample Size and Dimensionality on the Performance of Four Algorithms for Inference of Association Networks in Metabonomics

    NARCIS (Netherlands)

    Suarez Diez, M.; Saccenti, E.

    2015-01-01

    We investigated the effect of sample size and dimensionality on the performance of four algorithms (ARACNE, CLR, CORR, and PCLRC) when they are used for the inference of metabolite association networks. We report that as many as 100-400 samples may be necessary to obtain stable network estimations,

  3. Analysis of methods commonly used in biomedicine for treatment versus control comparison of very small samples.

    Science.gov (United States)

    Ristić-Djurović, Jasna L; Ćirković, Saša; Mladenović, Pavle; Romčević, Nebojša; Trbovich, Alexander M

    2018-04-01

    A rough estimate indicated that use of samples of size not larger than ten is not uncommon in biomedical research and that many of such studies are limited to strong effects due to sample sizes smaller than six. For data collected from biomedical experiments it is also often unknown if mathematical requirements incorporated in the sample comparison methods are satisfied. Computer simulated experiments were used to examine performance of methods for qualitative sample comparison and its dependence on the effectiveness of exposure, effect intensity, distribution of studied parameter values in the population, and sample size. The Type I and Type II errors, their average, as well as the maximal errors were considered. The sample size 9 and the t-test method with p = 5% ensured error smaller than 5% even for weak effects. For sample sizes 6-8 the same method enabled detection of weak effects with errors smaller than 20%. If the sample sizes were 3-5, weak effects could not be detected with an acceptable error; however, the smallest maximal error in the most general case that includes weak effects is granted by the standard error of the mean method. The increase of sample size from 5 to 9 led to seven times more accurate detection of weak effects. Strong effects were detected regardless of the sample size and method used. The minimal recommended sample size for biomedical experiments is 9. Use of smaller sizes and the method of their comparison should be justified by the objective of the experiment. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. ABCtoolbox: a versatile toolkit for approximate Bayesian computations

    Directory of Open Access Journals (Sweden)

    Neuenschwander Samuel

    2010-03-01

    Full Text Available Abstract Background The estimation of demographic parameters from genetic data often requires the computation of likelihoods. However, the likelihood function is computationally intractable for many realistic evolutionary models, and the use of Bayesian inference has therefore been limited to very simple models. The situation changed recently with the advent of Approximate Bayesian Computation (ABC algorithms allowing one to obtain parameter posterior distributions based on simulations not requiring likelihood computations. Results Here we present ABCtoolbox, a series of open source programs to perform Approximate Bayesian Computations (ABC. It implements various ABC algorithms including rejection sampling, MCMC without likelihood, a Particle-based sampler and ABC-GLM. ABCtoolbox is bundled with, but not limited to, a program that allows parameter inference in a population genetics context and the simultaneous use of different types of markers with different ploidy levels. In addition, ABCtoolbox can also interact with most simulation and summary statistics computation programs. The usability of the ABCtoolbox is demonstrated by inferring the evolutionary history of two evolutionary lineages of Microtus arvalis. Using nuclear microsatellites and mitochondrial sequence data in the same estimation procedure enabled us to infer sex-specific population sizes and migration rates and to find that males show smaller population sizes but much higher levels of migration than females. Conclusion ABCtoolbox allows a user to perform all the necessary steps of a full ABC analysis, from parameter sampling from prior distributions, data simulations, computation of summary statistics, estimation of posterior distributions, model choice, validation of the estimation procedure, and visualization of the results.

  5. Dental arch dimensions, form and tooth size ratio among a Saudi sample

    Directory of Open Access Journals (Sweden)

    Haidi Omar

    2018-01-01

    Full Text Available Objectives: To determine the dental arch dimensions and arch forms in a sample of Saudi orthodontic patients, to investigate the prevalence of Bolton anterior and overall tooth size discrepancies, and to compare the effect of gender on the measured parameters. Methods: This study is a biometric analysis of dental casts of 149 young adults recruited from different orthodontic centers in Jeddah, Saudi Arabia. The dental arch dimensions were measured. The measured parameters were arch length, arch width, Bolton’s ratio, and arch form. The data were analyzed using IBM SPSS software version 22.0 (IBM Corporation, New York, USA; this cross-sectional study was conducted between April 2015 and May 2016. Results: Dental arch measurements, including inter-canine and inter-molar distance, were found to be significantly greater in males than females (p less than 0.05. The most prevalent dental arch forms were narrow tapered (50.3% and narrow ovoid (34.2%, respectively. The prevalence of tooth size discrepancy in all cases was 43.6% for anterior ratio and 24.8% for overall ratio. The mean Bolton’s anterior ratio in all malocclusion classes was 79.81%, whereas the mean Bolton’s overall ratio was 92.21%. There was no significant difference between males and females regarding Bolton’s ratio. Conclusion: The most prevalent arch form was narrow tapered, followed by narrow ovoid. Males generally had larger dental arch measurements than females, and the prevalence of tooth size discrepancy was more in Bolton’s anterior teeth ratio than in overall ratio.

  6. What about N? A methodological study of sample-size reporting in focus group studies.

    Science.gov (United States)

    Carlsen, Benedicte; Glenton, Claire

    2011-03-11

    Focus group studies are increasingly published in health related journals, but we know little about how researchers use this method, particularly how they determine the number of focus groups to conduct. The methodological literature commonly advises researchers to follow principles of data saturation, although practical advise on how to do this is lacking. Our objectives were firstly, to describe the current status of sample size in focus group studies reported in health journals. Secondly, to assess whether and how researchers explain the number of focus groups they carry out. We searched PubMed for studies that had used focus groups and that had been published in open access journals during 2008, and extracted data on the number of focus groups and on any explanation authors gave for this number. We also did a qualitative assessment of the papers with regard to how number of groups was explained and discussed. We identified 220 papers published in 117 journals. In these papers insufficient reporting of sample sizes was common. The number of focus groups conducted varied greatly (mean 8.4, median 5, range 1 to 96). Thirty seven (17%) studies attempted to explain the number of groups. Six studies referred to rules of thumb in the literature, three stated that they were unable to organize more groups for practical reasons, while 28 studies stated that they had reached a point of saturation. Among those stating that they had reached a point of saturation, several appeared not to have followed principles from grounded theory where data collection and analysis is an iterative process until saturation is reached. Studies with high numbers of focus groups did not offer explanations for number of groups. Too much data as a study weakness was not an issue discussed in any of the reviewed papers. Based on these findings we suggest that journals adopt more stringent requirements for focus group method reporting. The often poor and inconsistent reporting seen in these

  7. What about N? A methodological study of sample-size reporting in focus group studies

    Directory of Open Access Journals (Sweden)

    Glenton Claire

    2011-03-01

    Full Text Available Abstract Background Focus group studies are increasingly published in health related journals, but we know little about how researchers use this method, particularly how they determine the number of focus groups to conduct. The methodological literature commonly advises researchers to follow principles of data saturation, although practical advise on how to do this is lacking. Our objectives were firstly, to describe the current status of sample size in focus group studies reported in health journals. Secondly, to assess whether and how researchers explain the number of focus groups they carry out. Methods We searched PubMed for studies that had used focus groups and that had been published in open access journals during 2008, and extracted data on the number of focus groups and on any explanation authors gave for this number. We also did a qualitative assessment of the papers with regard to how number of groups was explained and discussed. Results We identified 220 papers published in 117 journals. In these papers insufficient reporting of sample sizes was common. The number of focus groups conducted varied greatly (mean 8.4, median 5, range 1 to 96. Thirty seven (17% studies attempted to explain the number of groups. Six studies referred to rules of thumb in the literature, three stated that they were unable to organize more groups for practical reasons, while 28 studies stated that they had reached a point of saturation. Among those stating that they had reached a point of saturation, several appeared not to have followed principles from grounded theory where data collection and analysis is an iterative process until saturation is reached. Studies with high numbers of focus groups did not offer explanations for number of groups. Too much data as a study weakness was not an issue discussed in any of the reviewed papers. Conclusions Based on these findings we suggest that journals adopt more stringent requirements for focus group method

  8. An ergonomic evaluation comparing desktop, notebook, and subnotebook computers.

    Science.gov (United States)

    Szeto, Grace P; Lee, Raymond

    2002-04-01

    To evaluate and compare the postures and movements of the cervical and upper thoracic spine, the typing performance, and workstation ergonomic factors when using a desktop, notebook, and subnotebook computers. Repeated-measures design. A motion analysis laboratory with an electromagnetic tracking device. A convenience sample of 21 university students between ages 20 and 24 years with no history of neck or shoulder discomfort. Each subject performed a standardized typing task by using each of the 3 computers. Measurements during the typing task were taken at set intervals. Cervical and thoracic spines adopted a more flexed posture in using the smaller-sized computers. There were significantly greater neck movements in using desktop computers when compared with the notebook and subnotebook computers. The viewing distances adopted by the subjects decreased as the computer size decreased. Typing performance and subjective rating of difficulty in using the keyboards were also significantly different among the 3 types of computers. Computer users need to consider the posture of the spine and potential risk of developing musculoskeletal discomfort in choosing computers. Copyright 2002 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation

  9. The effects of parameter estimation on minimizing the in-control average sample size for the double sampling X bar chart

    Directory of Open Access Journals (Sweden)

    Michael B.C. Khoo

    2013-11-01

    Full Text Available The double sampling (DS X bar chart, one of the most widely-used charting methods, is superior for detecting small and moderate shifts in the process mean. In a right skewed run length distribution, the median run length (MRL provides a more credible representation of the central tendency than the average run length (ARL, as the mean is greater than the median. In this paper, therefore, MRL is used as the performance criterion instead of the traditional ARL. Generally, the performance of the DS X bar chart is investigated under the assumption of known process parameters. In practice, these parameters are usually estimated from an in-control reference Phase-I dataset. Since the performance of the DS X bar chart is significantly affected by estimation errors, we study the effects of parameter estimation on the MRL-based DS X bar chart when the in-control average sample size is minimised. This study reveals that more than 80 samples are required for the MRL-based DS X bar chart with estimated parameters to perform more favourably than the corresponding chart with known parameters.

  10. Software documentation and user's manual for fish-impingement sampling design and estimation method computer programs

    International Nuclear Information System (INIS)

    Murarka, I.P.; Bodeau, D.J.

    1977-11-01

    This report contains a description of three computer programs that implement the theory of sampling designs and the methods for estimating fish-impingement at the cooling-water intakes of nuclear power plants as described in companion report ANL/ES-60. Complete FORTRAN listings of these programs, named SAMPLE, ESTIMA, and SIZECO, are given and augmented with examples of how they are used

  11. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, S; Kadota, K; Kambara, H; Suzuki, Y; Nohara, R; Murakami, T; Kawai, C; Tamaki, N; Torizuka, K [Kyoto Univ. (Japan). Faculty of Medicine

    1984-07-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man.

  12. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    International Nuclear Information System (INIS)

    Tamaki, S.; Kadota, K.; Kambara, H.; Suzuki, Y.; Nohara, R.; Murakami, T.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-01-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man. (author)

  13. Quantification of errors in ordinal outcome scales using shannon entropy: effect on sample size calculations.

    Directory of Open Access Journals (Sweden)

    Pitchaiah Mandava

    Full Text Available OBJECTIVE: Clinical trial outcomes often involve an ordinal scale of subjective functional assessments but the optimal way to quantify results is not clear. In stroke, the most commonly used scale, the modified Rankin Score (mRS, a range of scores ("Shift" is proposed as superior to dichotomization because of greater information transfer. The influence of known uncertainties in mRS assessment has not been quantified. We hypothesized that errors caused by uncertainties could be quantified by applying information theory. Using Shannon's model, we quantified errors of the "Shift" compared to dichotomized outcomes using published distributions of mRS uncertainties and applied this model to clinical trials. METHODS: We identified 35 randomized stroke trials that met inclusion criteria. Each trial's mRS distribution was multiplied with the noise distribution from published mRS inter-rater variability to generate an error percentage for "shift" and dichotomized cut-points. For the SAINT I neuroprotectant trial, considered positive by "shift" mRS while the larger follow-up SAINT II trial was negative, we recalculated sample size required if classification uncertainty was taken into account. RESULTS: Considering the full mRS range, error rate was 26.1%±5.31 (Mean±SD. Error rates were lower for all dichotomizations tested using cut-points (e.g. mRS 1; 6.8%±2.89; overall p<0.001. Taking errors into account, SAINT I would have required 24% more subjects than were randomized. CONCLUSION: We show when uncertainty in assessments is considered, the lowest error rates are with dichotomization. While using the full range of mRS is conceptually appealing, a gain of information is counter-balanced by a decrease in reliability. The resultant errors need to be considered since sample size may otherwise be underestimated. In principle, we have outlined an approach to error estimation for any condition in which there are uncertainties in outcome assessment. We

  14. Dependence of fracture mechanical and fluid flow properties on fracture roughness and sample size

    International Nuclear Information System (INIS)

    Tsang, Y.W.; Witherspoon, P.A.

    1983-01-01

    A parameter study has been carried out to investigate the interdependence of mechanical and fluid flow properties of fractures with fracture roughness and sample size. A rough fracture can be defined mathematically in terms of its aperture density distribution. Correlations were found between the shapes of the aperture density distribution function and the specific fractures of the stress-strain behavior and fluid flow characteristics. Well-matched fractures had peaked aperture distributions that resulted in very nonlinear stress-strain behavior. With an increasing degree of mismatching between the top and bottom of a fracture, the aperture density distribution broadened and the nonlinearity of the stress-strain behavior became less accentuated. The different aperture density distributions also gave rise to qualitatively different fluid flow behavior. Findings from this investigation make it possible to estimate the stress-strain and fluid flow behavior when the roughness characteristics of the fracture are known and, conversely, to estimate the fracture roughness from an examination of the hydraulic and mechanical data. Results from this study showed that both the mechanical and hydraulic properties of the fracture are controlled by the large-scale roughness of the joint surface. This suggests that when the stress-flow behavior of a fracture is being investigated, the size of the rock sample should be larger than the typical wave length of the roughness undulations

  15. C-Arm Computed Tomography-Assisted Adrenal Venous Sampling Improved Right Adrenal Vein Cannulation and Sampling Quality in Primary Aldosteronism.

    Science.gov (United States)

    Park, Chung Hyun; Hong, Namki; Han, Kichang; Kang, Sang Wook; Lee, Cho Rok; Park, Sungha; Rhee, Yumie

    2018-05-04

    Adrenal venous sampling (AVS) is a gold standard for subtype classification of primary aldosteronism (PA). However, this procedure has a high failure rate because of the anatomical difficulties in accessing the right adrenal vein. We investigated whether C-arm computed tomography-assisted AVS (C-AVS) could improve the success rate of adrenal sampling. A total of 156 patients, diagnosed with PA who underwent AVS from May 2004 through April 2017, were included. Based on the medical records, we retrospectively compared the overall, left, and right catheterization success rates of adrenal veins during the periods without C-AVS (2004 to 2010, n=32) and with C-AVS (2011 to 2016, n=134). The primary outcome was adequate bilateral sampling defined as a selectivity index (SI) >5. With C-AVS, the rates of adequate bilateral AVS increased from 40.6% to 88.7% (PAVS was an independent predictor of adequate bilateral sampling in the multivariate model (odds ratio, 9.01; PAVS improved the overall success rate of AVS, possibly as a result of better catheterization of right adrenal vein. Copyright © 2018 Korean Endocrine Society.

  16. Size and asymmetry of the planum temporale. A new three-dimensional method for analysis of the supratemporal plane using MR imaging and computer-aided graphics

    International Nuclear Information System (INIS)

    Utsunomiya, H.; Nawata, M.; Ogasawara, T.; Okazaki, M.; Miyoshi, M.

    1996-01-01

    The planum temporale of the supratemporal plane is important for language function and shows left-right asymmetry in most brains. To estimate the size and allow side comparison of the planum temporale, we developed a new technique for 3-D MR analysis of the supratemporal plane using a personal computer and computer-aided graphics. The temporal lobes of 5 human cadavers were imaged by MR in the sagittal plane, at a slice thickness of 3 mm. The images of the supratemporal plane were entered into a personal computer using the original software to determine the positions of anatomic landmarks and the size of the planum temporale. The data were then transferred to a supercomputer to reconstruct the 3-D surface image of the supratemporal plane. Computer images of the spuratemporal plane agreed with macroscopic observations. The positions of anatomic landmarks and the size of the planum temporale also agreed with macroscopic measurements. Thus, the persent technique provides valuable anatomic data on the spuratemporal plane which should be useful for further clarification of the anatomic basis of language function. (orig.)

  17. SU-E-I-46: Sample-Size Dependence of Model Observers for Estimating Low-Contrast Detection Performance From CT Images

    International Nuclear Information System (INIS)

    Reiser, I; Lu, Z

    2014-01-01

    Purpose: Recently, task-based assessment of diagnostic CT systems has attracted much attention. Detection task performance can be estimated using human observers, or mathematical observer models. While most models are well established, considerable bias can be introduced when performance is estimated from a limited number of image samples. Thus, the purpose of this work was to assess the effect of sample size on bias and uncertainty of two channelized Hotelling observers and a template-matching observer. Methods: The image data used for this study consisted of 100 signal-present and 100 signal-absent regions-of-interest, which were extracted from CT slices. The experimental conditions included two signal sizes and five different x-ray beam current settings (mAs). Human observer performance for these images was determined in 2-alternative forced choice experiments. These data were provided by the Mayo clinic in Rochester, MN. Detection performance was estimated from three observer models, including channelized Hotelling observers (CHO) with Gabor or Laguerre-Gauss (LG) channels, and a template-matching observer (TM). Different sample sizes were generated by randomly selecting a subset of image pairs, (N=20,40,60,80). Observer performance was quantified as proportion of correct responses (PC). Bias was quantified as the relative difference of PC for 20 and 80 image pairs. Results: For n=100, all observer models predicted human performance across mAs and signal sizes. Bias was 23% for CHO (Gabor), 7% for CHO (LG), and 3% for TM. The relative standard deviation, σ(PC)/PC at N=20 was highest for the TM observer (11%) and lowest for the CHO (Gabor) observer (5%). Conclusion: In order to make image quality assessment feasible in the clinical practice, a statistically efficient observer model, that can predict performance from few samples, is needed. Our results identified two observer models that may be suited for this task

  18. (I Can’t Get No) Saturation: A Simulation and Guidelines for Minimum Sample Sizes in Qualitative Research

    NARCIS (Netherlands)

    van Rijnsoever, F.J.

    2015-01-01

    This paper explores the sample size in qualitative research that is required to reach theoretical saturation. I conceptualize a population as consisting of sub-populations that contain different types of information sources that hold a number of codes. Theoretical saturation is reached after all the

  19. Computer program for sizing residential energy recovery ventilator

    International Nuclear Information System (INIS)

    Koontz, M.D.; Lee, S.M.; Spears, J.W.; Kesselring, J.P.

    1991-01-01

    Energy recovery ventilators offer the prospect of tighter control over residential ventilation rates than manual methods, such as opening windows, with a lesser energy penalty. However, the appropriate size of such a ventilator is not readily apparent in most situations. Sizing of energy recovery ventilation software was developed to calculate the size of ventilator necessary to satisfy ASHRAE Standard 62-1989, Ventilation for Acceptable Air Quality, or a user-specified air exchange rate. Inputs to the software include house location, structural characteristics, house operations and energy costs, ventilation characteristics, and HVAC system COP/efficiency. Based on these inputs, the program estimates the existing air exchange rate for the house, the ventilation rate required to meet the ASHRAE standard or user-specified air exchange rate, the size of the ventilator needed to meet the requirement, and the expected changes in indoor air quality and energy consumption. In this paper an illustrative application of the software is provided

  20. Point Counts of Birds in Bottomland Hardwood Forests of the Mississippi Alluvial Valley: Duration, Minimum Sample Size, and Points Versus Visits

    Science.gov (United States)

    Winston Paul Smith; Daniel J. Twedt; David A. Wiedenfeld; Paul B. Hamel; Robert P. Ford; Robert J. Cooper

    1993-01-01

    To compare efficacy of point count sampling in bottomland hardwood forests, duration of point count, number of point counts, number of visits to each point during a breeding season, and minimum sample size are examined.

  1. Sample Size of One: Operational Qualitative Analysis in the Classroom

    Directory of Open Access Journals (Sweden)

    John Hoven

    2015-10-01

    Full Text Available Qualitative analysis has two extraordinary capabilities: first, finding answers to questions we are too clueless to ask; and second, causal inference – hypothesis testing and assessment – within a single unique context (sample size of one. These capabilities are broadly useful, and they are critically important in village-level civil-military operations. Company commanders need to learn quickly, "What are the problems and possibilities here and now, in this specific village? What happens if we do A, B, and C?" – and that is an ill-defined, one-of-a-kind problem. The U.S. Army's Eighty-Third Civil Affairs Battalion is our "first user" innovation partner in a new project to adapt qualitative research methods to an operational tempo and purpose. Our aim is to develop a simple, low-cost methodology and training program for local civil-military operations conducted by non-specialist conventional forces. Complementary to that, this paper focuses on some essential basics that can be implemented by college professors without significant cost, effort, or disruption.

  2. The Sizing and Optimization Language, (SOL): Computer language for design problems

    Science.gov (United States)

    Lucas, Stephen H.; Scotti, Stephen J.

    1988-01-01

    The Sizing and Optimization Language, (SOL), a new high level, special purpose computer language was developed to expedite application of numerical optimization to design problems and to make the process less error prone. SOL utilizes the ADS optimization software and provides a clear, concise syntax for describing an optimization problem, the OPTIMIZE description, which closely parallels the mathematical description of the problem. SOL offers language statements which can be used to model a design mathematically, with subroutines or code logic, and with existing FORTRAN routines. In addition, SOL provides error checking and clear output of the optimization results. Because of these language features, SOL is best suited to model and optimize a design concept when the model consits of mathematical expressions written in SOL. For such cases, SOL's unique syntax and error checking can be fully utilized. SOL is presently available for DEC VAX/VMS systems. A SOL package is available which includes the SOL compiler, runtime library routines, and a SOL reference manual.

  3. Self-navigation of a scanning tunneling microscope tip toward a micron-sized graphene sample.

    Science.gov (United States)

    Li, Guohong; Luican, Adina; Andrei, Eva Y

    2011-07-01

    We demonstrate a simple capacitance-based method to quickly and efficiently locate micron-sized conductive samples, such as graphene flakes, on insulating substrates in a scanning tunneling microscope (STM). By using edge recognition, the method is designed to locate and to identify small features when the STM tip is far above the surface, allowing for crash-free search and navigation. The method can be implemented in any STM environment, even at low temperatures and in strong magnetic field, with minimal or no hardware modifications.

  4. Tamaños de muestra para estimar la estructura de tallas de las capturas de langostino colorado en la zona centro-norte de Chile: una aproximación a través de remuestreo Sample sizes for estimating the catch size distribution of squat lobster in north-central Chile: a resampling approach

    Directory of Open Access Journals (Sweden)

    Carlos Montenegro Silva

    2009-01-01

    Full Text Available Se analizó el desempeño de distintos tamaños de muestra para estimar la composición de tallas de las capturas del langostino colorado (Pleuroncodes monodon, a partir de un procedimiento de remuestreo computacional. Se seleccionaron datos recolectados en mayo de 2002 entre los 29°10'S y 32°10'S. A partir de éstos, se probaron siete escenarios de muestreo de viajes de pesca (1-7 viajes, 12 escenarios de número de ejemplares muestreados (25, 50,...300, cada 25 ejemplares y dos estrategias de muestreo de lances de pesca al interior de un viaje de pesca (censo de lances y muestreo sistemático. Se probó la combinación de todos estos escenarios, lo que permitió analizar el desempeño de 168 escenarios de tamaño de muestra para estimar la composición de tallas por sexo. Los resultados indicaron una disminución en el índice de error en la estimación de la distribución de frecuencia de tallas, conforme aumentó el número de viajes de pesca, con disminuciones progresivamente menores entre escenarios adyacentes. Del mismo modo, se verificó una disminución en el índice de error al aumentar el número de ejemplares muestreados, con mejoras marginales sobre los 175 ejemplares.The performances of different sample sizes for estimating the size distribution of squat lobster (Pleuroncodes monodon catches were analyzed using a computer resampling procedure. The data selected were gathered in May 2002 between 29°10'S and 32°10'S. These data were used to test seven sampling scenarios for fishing trips (1-7 trips, twelve scenarios of the number of individuals sampled per tow (25, 50,..., 300, and two within-trip sampling strategies (sampling all tows and systematic tow sampling. By testing the combination of all these scenarios, we were able to analyze the performance of 168 scenarios of sample size for estimating the composition of sizes by sex. The results indicate a lower error index for estimates of the size frequency distribution as the

  5. X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

    Science.gov (United States)

    Ziegler, R. A.; Almeida, N. V.; Sykes, D.; Smith, C. L.

    2014-01-01

    X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass

  6. A Systematic Review of Surgical Randomized Controlled Trials: Part 2. Funding Source, Conflict of Interest, and Sample Size in Plastic Surgery.

    Science.gov (United States)

    Voineskos, Sophocles H; Coroneos, Christopher J; Ziolkowski, Natalia I; Kaur, Manraj N; Banfield, Laura; Meade, Maureen O; Chung, Kevin C; Thoma, Achilleas; Bhandari, Mohit

    2016-02-01

    The authors examined industry support, conflict of interest, and sample size in plastic surgery randomized controlled trials that compared surgical interventions. They hypothesized that industry-funded trials demonstrate statistically significant outcomes more often, and randomized controlled trials with small sample sizes report statistically significant results more frequently. An electronic search identified randomized controlled trials published between 2000 and 2013. Independent reviewers assessed manuscripts and performed data extraction. Funding source, conflict of interest, primary outcome direction, and sample size were examined. Chi-squared and independent-samples t tests were used in the analysis. The search identified 173 randomized controlled trials, of which 100 (58 percent) did not acknowledge funding status. A relationship between funding source and trial outcome direction was not observed. Both funding status and conflict of interest reporting improved over time. Only 24 percent (six of 25) of industry-funded randomized controlled trials reported authors to have independent control of data and manuscript contents. The mean number of patients randomized was 73 per trial (median, 43, minimum, 3, maximum, 936). Small trials were not found to be positive more often than large trials (p = 0.87). Randomized controlled trials with small sample size were common; however, this provides great opportunity for the field to engage in further collaboration and produce larger, more definitive trials. Reporting of trial funding and conflict of interest is historically poor, but it greatly improved over the study period. Underreporting at author and journal levels remains a limitation when assessing the relationship between funding source and trial outcomes. Improved reporting and manuscript control should be goals that both authors and journals can actively achieve.

  7. The Effect of Small Sample Size on Measurement Equivalence of Psychometric Questionnaires in MIMIC Model: A Simulation Study

    Directory of Open Access Journals (Sweden)

    Jamshid Jamali

    2017-01-01

    Full Text Available Evaluating measurement equivalence (also known as differential item functioning (DIF is an important part of the process of validating psychometric questionnaires. This study aimed at evaluating the multiple indicators multiple causes (MIMIC model for DIF detection when latent construct distribution is nonnormal and the focal group sample size is small. In this simulation-based study, Type I error rates and power of MIMIC model for detecting uniform-DIF were investigated under different combinations of reference to focal group sample size ratio, magnitude of the uniform-DIF effect, scale length, the number of response categories, and latent trait distribution. Moderate and high skewness in the latent trait distribution led to a decrease of 0.33% and 0.47% power of MIMIC model for detecting uniform-DIF, respectively. The findings indicated that, by increasing the scale length, the number of response categories and magnitude DIF improved the power of MIMIC model, by 3.47%, 4.83%, and 20.35%, respectively; it also decreased Type I error of MIMIC approach by 2.81%, 5.66%, and 0.04%, respectively. This study revealed that power of MIMIC model was at an acceptable level when latent trait distributions were skewed. However, empirical Type I error rate was slightly greater than nominal significance level. Consequently, the MIMIC was recommended for detection of uniform-DIF when latent construct distribution is nonnormal and the focal group sample size is small.

  8. The Effect of Small Sample Size on Measurement Equivalence of Psychometric Questionnaires in MIMIC Model: A Simulation Study.

    Science.gov (United States)

    Jamali, Jamshid; Ayatollahi, Seyyed Mohammad Taghi; Jafari, Peyman

    2017-01-01

    Evaluating measurement equivalence (also known as differential item functioning (DIF)) is an important part of the process of validating psychometric questionnaires. This study aimed at evaluating the multiple indicators multiple causes (MIMIC) model for DIF detection when latent construct distribution is nonnormal and the focal group sample size is small. In this simulation-based study, Type I error rates and power of MIMIC model for detecting uniform-DIF were investigated under different combinations of reference to focal group sample size ratio, magnitude of the uniform-DIF effect, scale length, the number of response categories, and latent trait distribution. Moderate and high skewness in the latent trait distribution led to a decrease of 0.33% and 0.47% power of MIMIC model for detecting uniform-DIF, respectively. The findings indicated that, by increasing the scale length, the number of response categories and magnitude DIF improved the power of MIMIC model, by 3.47%, 4.83%, and 20.35%, respectively; it also decreased Type I error of MIMIC approach by 2.81%, 5.66%, and 0.04%, respectively. This study revealed that power of MIMIC model was at an acceptable level when latent trait distributions were skewed. However, empirical Type I error rate was slightly greater than nominal significance level. Consequently, the MIMIC was recommended for detection of uniform-DIF when latent construct distribution is nonnormal and the focal group sample size is small.

  9. Sample size effect on the determination of the irreversibility line of high-Tc superconductors

    International Nuclear Information System (INIS)

    Li, Q.; Suenaga, M.; Li, Q.; Freltoft, T.

    1994-01-01

    The irreversibility lines of a high-J c superconducting Bi 2 Sr 2 Ca 2 Cu 3 O x /Ag tape were systematically measured upon a sequence of subdivisions of the sample. The irreversibility field H r (T) (parallel to the c axis) was found to change approximately as L 0.13 , where L is the effective dimension of the superconducting tape. Furthermore, it was found that the irreversibility line for a grain-aligned Bi 2 Sr 2 Ca 2 Cu 3 O x specimen can be approximately reproduced by the extrapolation of this relation down to a grain size of a few tens of micrometers. The observed size effect could significantly obscure the real physical meaning of the irreversibility lines. In addition, this finding surprisingly indicated that the Bi 2 Sr 2 Ca 2 Cu 2 O x /Ag tape and grain-aligned specimen may have similar flux line pinning strength

  10. Multiple sensitive estimation and optimal sample size allocation in the item sum technique.

    Science.gov (United States)

    Perri, Pier Francesco; Rueda García, María Del Mar; Cobo Rodríguez, Beatriz

    2018-01-01

    For surveys of sensitive issues in life sciences, statistical procedures can be used to reduce nonresponse and social desirability response bias. Both of these phenomena provoke nonsampling errors that are difficult to deal with and can seriously flaw the validity of the analyses. The item sum technique (IST) is a very recent indirect questioning method derived from the item count technique that seeks to procure more reliable responses on quantitative items than direct questioning while preserving respondents' anonymity. This article addresses two important questions concerning the IST: (i) its implementation when two or more sensitive variables are investigated and efficient estimates of their unknown population means are required; (ii) the determination of the optimal sample size to achieve minimum variance estimates. These aspects are of great relevance for survey practitioners engaged in sensitive research and, to the best of our knowledge, were not studied so far. In this article, theoretical results for multiple estimation and optimal allocation are obtained under a generic sampling design and then particularized to simple random sampling and stratified sampling designs. Theoretical considerations are integrated with a number of simulation studies based on data from two real surveys and conducted to ascertain the efficiency gain derived from optimal allocation in different situations. One of the surveys concerns cannabis consumption among university students. Our findings highlight some methodological advances that can be obtained in life sciences IST surveys when optimal allocation is achieved. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Sample size determinations for group-based randomized clinical trials with different levels of data hierarchy between experimental and control arms.

    Science.gov (United States)

    Heo, Moonseong; Litwin, Alain H; Blackstock, Oni; Kim, Namhee; Arnsten, Julia H

    2017-02-01

    We derived sample size formulae for detecting main effects in group-based randomized clinical trials with different levels of data hierarchy between experimental and control arms. Such designs are necessary when experimental interventions need to be administered to groups of subjects whereas control conditions need to be administered to individual subjects. This type of trial, often referred to as a partially nested or partially clustered design, has been implemented for management of chronic diseases such as diabetes and is beginning to emerge more commonly in wider clinical settings. Depending on the research setting, the level of hierarchy of data structure for the experimental arm can be three or two, whereas that for the control arm is two or one. Such different levels of data hierarchy assume correlation structures of outcomes that are different between arms, regardless of whether research settings require two or three level data structure for the experimental arm. Therefore, the different correlations should be taken into account for statistical modeling and for sample size determinations. To this end, we considered mixed-effects linear models with different correlation structures between experimental and control arms to theoretically derive and empirically validate the sample size formulae with simulation studies.

  12. Gridsampler – A Simulation Tool to Determine the Required Sample Size for Repertory Grid Studies

    OpenAIRE

    Heckmann, Mark; Burk, Lukas

    2017-01-01

    The repertory grid is a psychological data collection technique that is used to elicit qualitative data in the form of attributes as well as quantitative ratings. A common approach for evaluating multiple repertory grid data is sorting the elicited bipolar attributes (so called constructs) into mutually exclusive categories by means of content analysis. An important question when planning this type of study is determining the sample size needed to a) discover all attribute categories relevant...

  13. Reproducibility of 5-HT2A receptor measurements and sample size estimations with [18F]altanserin PET using a bolus/infusion approach

    DEFF Research Database (Denmark)

    Haugbøl, Steven; Pinborg, Lars H; Arfan, Haroon M

    2006-01-01

    PURPOSE: To determine the reproducibility of measurements of brain 5-HT2A receptors with an [18F]altanserin PET bolus/infusion approach. Further, to estimate the sample size needed to detect regional differences between two groups and, finally, to evaluate how partial volume correction affects...... reproducibility and the required sample size. METHODS: For assessment of the variability, six subjects were investigated with [18F]altanserin PET twice, at an interval of less than 2 weeks. The sample size required to detect a 20% difference was estimated from [18F]altanserin PET studies in 84 healthy subjects....... Regions of interest were automatically delineated on co-registered MR and PET images. RESULTS: In cortical brain regions with a high density of 5-HT2A receptors, the outcome parameter (binding potential, BP1) showed high reproducibility, with a median difference between the two group measurements of 6...

  14. A comparison of confidence/credible interval methods for the area under the ROC curve for continuous diagnostic tests with small sample size.

    Science.gov (United States)

    Feng, Dai; Cortese, Giuliana; Baumgartner, Richard

    2017-12-01

    The receiver operating characteristic (ROC) curve is frequently used as a measure of accuracy of continuous markers in diagnostic tests. The area under the ROC curve (AUC) is arguably the most widely used summary index for the ROC curve. Although the small sample size scenario is common in medical tests, a comprehensive study of small sample size properties of various methods for the construction of the confidence/credible interval (CI) for the AUC has been by and large missing in the literature. In this paper, we describe and compare 29 non-parametric and parametric methods for the construction of the CI for the AUC when the number of available observations is small. The methods considered include not only those that have been widely adopted, but also those that have been less frequently mentioned or, to our knowledge, never applied to the AUC context. To compare different methods, we carried out a simulation study with data generated from binormal models with equal and unequal variances and from exponential models with various parameters and with equal and unequal small sample sizes. We found that the larger the true AUC value and the smaller the sample size, the larger the discrepancy among the results of different approaches. When the model is correctly specified, the parametric approaches tend to outperform the non-parametric ones. Moreover, in the non-parametric domain, we found that a method based on the Mann-Whitney statistic is in general superior to the others. We further elucidate potential issues and provide possible solutions to along with general guidance on the CI construction for the AUC when the sample size is small. Finally, we illustrate the utility of different methods through real life examples.

  15. Computational analyses of ancient pathogen DNA from herbarium samples: challenges and prospects.

    Science.gov (United States)

    Yoshida, Kentaro; Sasaki, Eriko; Kamoun, Sophien

    2015-01-01

    The application of DNA sequencing technology to the study of ancient DNA has enabled the reconstruction of past epidemics from genomes of historically important plant-associated microbes. Recently, the genome sequences of the potato late blight pathogen Phytophthora infestans were analyzed from 19th century herbarium specimens. These herbarium samples originated from infected potatoes collected during and after the Irish potato famine. Herbaria have therefore great potential to help elucidate past epidemics of crops, date the emergence of pathogens, and inform about past pathogen population dynamics. DNA preservation in herbarium samples was unexpectedly good, raising the possibility of a whole new research area in plant and microbial genomics. However, the recovered DNA can be extremely fragmented resulting in specific challenges in reconstructing genome sequences. Here we review some of the challenges in computational analyses of ancient DNA from herbarium samples. We also applied the recently developed linkage method to haplotype reconstruction of diploid or polyploid genomes from fragmented ancient DNA.

  16. Carotid body size measured by computed tomographic angiography in individuals born prematurely.

    Science.gov (United States)

    Bates, Melissa L; Welch, Brian T; Randall, Jess T; Petersen-Jones, Humphrey G; Limberg, Jacqueline K

    2018-05-24

    We tested the hypothesis that the carotid bodies would be smaller in individuals born prematurely or exposed to perinatal oxygen therapy when compared individuals born full term that did not receive oxygen therapy. A retrospective chart review was conducted on patients who underwent head/neck computed tomography angiography (CTA) at the Mayo Clinic between 10 and 40 years of age (n = 2503). Patients were identified as premature ( body images captured during the CTA were performed. Carotid body visualization was possible in 43% of patients and 52% of age, sex, and body mass index (BMI)-matched controls but only 17% of juvenile preterm subjects (p = 0.07). Of the carotid bodies that could be visualized, widest axial measurements of the carotid bodies in individuals born prematurely (n = 7, 34 ± 4 weeks gestation, birth weight: 2460 ± 454 g; average size: 2.5 ± 0.2 cm) or individuals exposed to perinatal oxygen therapy (n = 3, 38 ± 2 weeks gestation, Average size: 2.2 ± 0.1 cm) were not different when compared to controls (2.3 ± 0.2 cm and 2.3 ± 0.2 cm, respectively, p > 0.05). Carotid body size, as measured using CTA, is not smaller in adults born prematurely or exposed to perinatal oxygen therapy when compared to sex, age, and BMI-matched controls. However, carotid body visualization was lower in juvenile premature patients. The decreased ability to visualize the carotid bodies in these individuals may be a result of their prematurity. Copyright © 2018. Published by Elsevier B.V.

  17. Transportable high sensitivity small sample radiometric calorimeter

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-01-01

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most 238 Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size

  18. DOSESCREEN: a computer program to aid dose placement

    Science.gov (United States)

    Kimberly C. Smith; Jacqueline L. Robertson

    1984-01-01

    Careful selection of an experimental design for a bioassay substantially improves the precision of effective dose (ED) estimates. Design considerations typically include determination of sample size, dose selection, and allocation of subjects to doses. DOSESCREEN is a computer program written to help investigators select an efficient design for the estimation of an...

  19. Size-exclusion chromatography-based enrichment of extracellular vesicles from urine samples

    Directory of Open Access Journals (Sweden)

    Inés Lozano-Ramos

    2015-05-01

    Full Text Available Renal biopsy is the gold-standard procedure to diagnose most of renal pathologies. However, this invasive method is of limited repeatability and often describes an irreversible renal damage. Urine is an easily accessible fluid and urinary extracellular vesicles (EVs may be ideal to describe new biomarkers associated with renal pathologies. Several methods to enrich EVs have been described. Most of them contain a mixture of proteins, lipoproteins and cell debris that may be masking relevant biomarkers. Here, we evaluated size-exclusion chromatography (SEC as a suitable method to isolate urinary EVs. Following a conventional centrifugation to eliminate cell debris and apoptotic bodies, urine samples were concentrated using ultrafiltration and loaded on a SEC column. Collected fractions were analysed by protein content and flow cytometry to determine the presence of tetraspanin markers (CD63 and CD9. The highest tetraspanin content was routinely detected in fractions well before the bulk of proteins eluted. These tetraspanin-peak fractions were analysed by cryo-electron microscopy (cryo-EM and nanoparticle tracking analysis revealing the presence of EVs.When analysed by sodium dodecyl sulphate–polyacrylamide gel electrophoresis, tetraspanin-peak fractions from urine concentrated samples contained multiple bands but the main urine proteins (such as Tamm–Horsfall protein were absent. Furthermore, a preliminary proteomic study of these fractions revealed the presence of EV-related proteins, suggesting their enrichment in concentrated samples. In addition, RNA profiling also showed the presence of vesicular small RNA species.To summarize, our results demonstrated that concentrated urine followed by SEC is a suitable option to isolate EVs with low presence of soluble contaminants. This methodology could permit more accurate analyses of EV-related biomarkers when further characterized by -omics technologies compared with other approaches.

  20. Classifier-guided sampling for discrete variable, discontinuous design space exploration: Convergence and computational performance

    Energy Technology Data Exchange (ETDEWEB)

    Backlund, Peter B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Shahan, David W. [HRL Labs., LLC, Malibu, CA (United States); Seepersad, Carolyn Conner [Univ. of Texas, Austin, TX (United States)

    2014-04-22

    A classifier-guided sampling (CGS) method is introduced for solving engineering design optimization problems with discrete and/or continuous variables and continuous and/or discontinuous responses. The method merges concepts from metamodel-guided sampling and population-based optimization algorithms. The CGS method uses a Bayesian network classifier for predicting the performance of new designs based on a set of known observations or training points. Unlike most metamodeling techniques, however, the classifier assigns a categorical class label to a new design, rather than predicting the resulting response in continuous space, and thereby accommodates nondifferentiable and discontinuous functions of discrete or categorical variables. The CGS method uses these classifiers to guide a population-based sampling process towards combinations of discrete and/or continuous variable values with a high probability of yielding preferred performance. Accordingly, the CGS method is appropriate for discrete/discontinuous design problems that are ill-suited for conventional metamodeling techniques and too computationally expensive to be solved by population-based algorithms alone. In addition, the rates of convergence and computational properties of the CGS method are investigated when applied to a set of discrete variable optimization problems. Results show that the CGS method significantly improves the rate of convergence towards known global optima, on average, when compared to genetic algorithms.

  1. Matching Ge detector element geometry to sample size and shape: One does not fit all exclamation point

    International Nuclear Information System (INIS)

    Keyser, R.M.; Twomey, T.R.; Sangsingkeow, P.

    1998-01-01

    For 25 yr, coaxial germanium detector performance has been specified using the methods and values specified in Ref. 1. These specifications are the full-width at half-maximum (FWHM), FW.1M, FW.02M, peak-to-Compton ratio, and relative efficiency. All of these measurements are made with a 60 Co source 25 cm from the cryostat endcap and centered on the axis of the detector. These measurements are easy to reproduce, both because they are simple to set up and use a common source. These standard tests have been useful in guiding the user to an appropriate detector choice for the intended measurement. Most users of germanium gamma-ray detectors do not make measurements in this simple geometry. Germanium detector manufacturers have worked over the years to make detectors with better resolution, better peak-to-Compton ratios, and higher efficiency--but all based on measurements using the IEEE standard. Advances in germanium crystal growth techniques have made it relatively easy to provide detector elements of different shapes and sizes. Many of these different shapes and sizes can give better results for a specific application than other shapes and sizes. But, the detector specifications must be changed to correspond to the actual application. Both the expected values and the actual parameters to be specified should be changed. In many cases, detection efficiency, peak shape, and minimum detectable limit for a particular detector/sample combination are valuable specifications of detector performance. For other situations, other parameters are important, such as peak shape as a function of count rate. In this work, different sample geometries were considered. The results show the variation in efficiency with energy for all of these sample and detector geometries. The point source at 25 cm from the endcap measurement allows the results to be compared with the currently given IEEE criteria. The best sample/detector configuration for a specific measurement requires more and

  2. Binomial Distribution Sample Confidence Intervals Estimation 7. Absolute Risk Reduction and ARR-like Expressions

    Directory of Open Access Journals (Sweden)

    Andrei ACHIMAŞ CADARIU

    2004-08-01

    Full Text Available Assessments of a controlled clinical trial suppose to interpret some key parameters as the controlled event rate, experimental event date, relative risk, absolute risk reduction, relative risk reduction, number needed to treat when the effect of the treatment are dichotomous variables. Defined as the difference in the event rate between treatment and control groups, the absolute risk reduction is the parameter that allowed computing the number needed to treat. The absolute risk reduction is compute when the experimental treatment reduces the risk for an undesirable outcome/event. In medical literature when the absolute risk reduction is report with its confidence intervals, the method used is the asymptotic one, even if it is well know that may be inadequate. The aim of this paper is to introduce and assess nine methods of computing confidence intervals for absolute risk reduction and absolute risk reduction – like function.Computer implementations of the methods use the PHP language. Methods comparison uses the experimental errors, the standard deviations, and the deviation relative to the imposed significance level for specified sample sizes. Six methods of computing confidence intervals for absolute risk reduction and absolute risk reduction-like functions were assessed using random binomial variables and random sample sizes.The experiments shows that the ADAC, and ADAC1 methods obtains the best overall performance of computing confidence intervals for absolute risk reduction.

  3. Phase-contrast x-ray computed tomography for biological imaging

    Science.gov (United States)

    Momose, Atsushi; Takeda, Tohoru; Itai, Yuji

    1997-10-01

    We have shown so far that 3D structures in biological sot tissues such as cancer can be revealed by phase-contrast x- ray computed tomography using an x-ray interferometer. As a next step, we aim at applications of this technique to in vivo observation, including radiographic applications. For this purpose, the size of view field is desired to be more than a few centimeters. Therefore, a larger x-ray interferometer should be used with x-rays of higher energy. We have evaluated the optimal x-ray energy from an aspect of does as a function of sample size. Moreover, desired spatial resolution to an image sensor is discussed as functions of x-ray energy and sample size, basing on a requirement in the analysis of interference fringes.

  4. Quantification of myocardial infarct size by technetium-99m pyrophosphate single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiromichi; Fukuyama, Takaya; Aoki, Makoto; Inou, Tetsuji; Ashihara, Toshiaki; Nabeyama, Shyohzou; Yamamoto, Yuhsuke

    1989-04-01

    Myocardial infarct size in 41 patients with the first attack of acute transmural myocardial infarction (MI) was assessed by technetium-99m pyrophosphate single photon emission computed tomography (/sup 99m/TcPYP-SPECT). A ratio of the number of voxels of /sup 99m/TcPYP uptake into the infarct area to that into the thorax was calculated as a parameter of MI size. The ratio was positively correlated with both peak CPK activity (r=0.53, p<0.005, n=24) and extent score in /sup 201/Tl-SPECT (r=0.70, p<0.005, n=14) significantly in patients with anterior MI but not in patients with inferior MI. There was also significant negative correlation between the ratio and the left ventricular ejection fraction (LVEF) measured by RI angiography in both acute (r=-0.67, p<0.005, n=18) and chronic (r=-0.75, p<0.005, n=25) phases in patients with anterior MI. Recovery in LVEF at chronic phase was noted in patients with small anterior MI but not with large anterior MI. Eight of 14 patients with inferior MI had right ventricular MI, that might have affected evaluation of MI size and resulted in no correlation between variables. It was suggested that /sup 99m/TcPYP-SPECT was a useful method to evaluate MI size and to predict prognosis of cardiac function in patients with anterior MI but not in patients with inferior MI. (author).

  5. Sampling of systematic errors to estimate likelihood weights in nuclear data uncertainty propagation

    International Nuclear Information System (INIS)

    Helgesson, P.; Sjöstrand, H.; Koning, A.J.; Rydén, J.; Rochman, D.; Alhassan, E.; Pomp, S.

    2016-01-01

    In methodologies for nuclear data (ND) uncertainty assessment and propagation based on random sampling, likelihood weights can be used to infer experimental information into the distributions for the ND. As the included number of correlated experimental points grows large, the computational time for the matrix inversion involved in obtaining the likelihood can become a practical problem. There are also other problems related to the conventional computation of the likelihood, e.g., the assumption that all experimental uncertainties are Gaussian. In this study, a way to estimate the likelihood which avoids matrix inversion is investigated; instead, the experimental correlations are included by sampling of systematic errors. It is shown that the model underlying the sampling methodology (using univariate normal distributions for random and systematic errors) implies a multivariate Gaussian for the experimental points (i.e., the conventional model). It is also shown that the likelihood estimates obtained through sampling of systematic errors approach the likelihood obtained with matrix inversion as the sample size for the systematic errors grows large. In studied practical cases, it is seen that the estimates for the likelihood weights converge impractically slowly with the sample size, compared to matrix inversion. The computational time is estimated to be greater than for matrix inversion in cases with more experimental points, too. Hence, the sampling of systematic errors has little potential to compete with matrix inversion in cases where the latter is applicable. Nevertheless, the underlying model and the likelihood estimates can be easier to intuitively interpret than the conventional model and the likelihood function involving the inverted covariance matrix. Therefore, this work can both have pedagogical value and be used to help motivating the conventional assumption of a multivariate Gaussian for experimental data. The sampling of systematic errors could also

  6. Impact of cone-beam computed tomography on implant planning and on prediction of implant size

    Energy Technology Data Exchange (ETDEWEB)

    Pedroso, Ludmila Assuncao de Mello; Silva, Maria Alves Garcia Santos, E-mail: ludmilapedroso@hotmail.com [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia; Garcia, Robson Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Medicina Oral; Leles, Jose Luiz Rodrigues [Universidade Paulista (UNIP), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Cirurgia; Leles, Claudio Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Prevencao e Reabilitacao Oral

    2013-11-15

    The aim was to investigate the impact of cone-beam computed tomography (CBCT) on implant planning and on prediction of final implant size. Consecutive patients referred for implant treatment were submitted to clinical examination, panoramic (PAN) radiography and a CBCT exam. Initial planning of implant length and width was assessed based on clinical and PAN exams, and final planning, on CBCT exam to complement diagnosis. The actual dimensions of the implants placed during surgery were compared with those obtained during initial and final planning, using the McNemmar test (p < 0.05). The final sample comprised 95 implants in 27 patients, distributed over the maxilla and mandible. Agreement in implant length was 50.5% between initial and final planning, and correct prediction of the actual implant length was 40.0% and 69.5%, using PAN and CBCT exams, respectively. Agreement in implant width assessment ranged from 69.5% to 73.7%. A paired comparison of the frequency of changes between initial or final planning and implant placement (McNemmar test) showed greater frequency of changes in initial planning for implant length (p < 0.001), but not for implant width (p = 0.850). The frequency of changes was not influenced by implant location at any stage of implant planning (chi-square test, p > 0.05). It was concluded that CBCT improves the ability of predicting the actual implant length and reduces inaccuracy in surgical dental implant planning. (author)

  7. Weighted piecewise LDA for solving the small sample size problem in face verification.

    Science.gov (United States)

    Kyperountas, Marios; Tefas, Anastasios; Pitas, Ioannis

    2007-03-01

    A novel algorithm that can be used to boost the performance of face-verification methods that utilize Fisher's criterion is presented and evaluated. The algorithm is applied to similarity, or matching error, data and provides a general solution for overcoming the "small sample size" (SSS) problem, where the lack of sufficient training samples causes improper estimation of a linear separation hyperplane between the classes. Two independent phases constitute the proposed method. Initially, a set of weighted piecewise discriminant hyperplanes are used in order to provide a more accurate discriminant decision than the one produced by the traditional linear discriminant analysis (LDA) methodology. The expected classification ability of this method is investigated throughout a series of simulations. The second phase defines proper combinations for person-specific similarity scores and describes an outlier removal process that further enhances the classification ability. The proposed technique has been tested on the M2VTS and XM2VTS frontal face databases. Experimental results indicate that the proposed framework greatly improves the face-verification performance.

  8. Problems with sampling desert tortoises: A simulation analysis based on field data

    Science.gov (United States)

    Freilich, J.E.; Camp, R.J.; Duda, J.J.; Karl, A.E.

    2005-01-01

    The desert tortoise (Gopherus agassizii) was listed as a U.S. threatened species in 1990 based largely on population declines inferred from mark-recapture surveys of 2.59-km2 (1-mi2) plots. Since then, several census methods have been proposed and tested, but all methods still pose logistical or statistical difficulties. We conducted computer simulations using actual tortoise location data from 2 1-mi2 plot surveys in southern California, USA, to identify strengths and weaknesses of current sampling strategies. We considered tortoise population estimates based on these plots as "truth" and then tested various sampling methods based on sampling smaller plots or transect lines passing through the mile squares. Data were analyzed using Schnabel's mark-recapture estimate and program CAPTURE. Experimental subsampling with replacement of the 1-mi2 data using 1-km2 and 0.25-km2 plot boundaries produced data sets of smaller plot sizes, which we compared to estimates from the 1-mi 2 plots. We also tested distance sampling by saturating a 1-mi 2 site with computer simulated transect lines, once again evaluating bias in density estimates. Subsampling estimates from 1-km2 plots did not differ significantly from the estimates derived at 1-mi2. The 0.25-km2 subsamples significantly overestimated population sizes, chiefly because too few recaptures were made. Distance sampling simulations were biased 80% of the time and had high coefficient of variation to density ratios. Furthermore, a prospective power analysis suggested limited ability to detect population declines as high as 50%. We concluded that poor performance and bias of both sampling procedures was driven by insufficient sample size, suggesting that all efforts must be directed to increasing numbers found in order to produce reliable results. Our results suggest that present methods may not be capable of accurately estimating desert tortoise populations.

  9. Evaluating sampling strategy for DNA barcoding study of coastal and inland halo-tolerant Poaceae and Chenopodiaceae: A case study for increased sample size.

    Science.gov (United States)

    Yao, Peng-Cheng; Gao, Hai-Yan; Wei, Ya-Nan; Zhang, Jian-Hang; Chen, Xiao-Yong; Li, Hong-Qing

    2017-01-01

    Environmental conditions in coastal salt marsh habitats have led to the development of specialist genetic adaptations. We evaluated six DNA barcode loci of the 53 species of Poaceae and 15 species of Chenopodiaceae from China's coastal salt marsh area and inland area. Our results indicate that the optimum DNA barcode was ITS for coastal salt-tolerant Poaceae and matK for the Chenopodiaceae. Sampling strategies for ten common species of Poaceae and Chenopodiaceae were analyzed according to optimum barcode. We found that by increasing the number of samples collected from the coastal salt marsh area on the basis of inland samples, the number of haplotypes of Arundinella hirta, Digitaria ciliaris, Eleusine indica, Imperata cylindrica, Setaria viridis, and Chenopodium glaucum increased, with a principal coordinate plot clearly showing increased distribution points. The results of a Mann-Whitney test showed that for Digitaria ciliaris, Eleusine indica, Imperata cylindrica, and Setaria viridis, the distribution of intraspecific genetic distances was significantly different when samples from the coastal salt marsh area were included (P Imperata cylindrica and Chenopodium album, average intraspecific distance tended to reach stability. These results indicate that the sample size for DNA barcode of globally distributed species should be increased to 11-15.

  10. Estimation of Finite Population Mean in Multivariate Stratified Sampling under Cost Function Using Goal Programming

    Directory of Open Access Journals (Sweden)

    Atta Ullah

    2014-01-01

    Full Text Available In practical utilization of stratified random sampling scheme, the investigator meets a problem to select a sample that maximizes the precision of a finite population mean under cost constraint. An allocation of sample size becomes complicated when more than one characteristic is observed from each selected unit in a sample. In many real life situations, a linear cost function of a sample size nh is not a good approximation to actual cost of sample survey when traveling cost between selected units in a stratum is significant. In this paper, sample allocation problem in multivariate stratified random sampling with proposed cost function is formulated in integer nonlinear multiobjective mathematical programming. A solution procedure is proposed using extended lexicographic goal programming approach. A numerical example is presented to illustrate the computational details and to compare the efficiency of proposed compromise allocation.

  11. A reference sample for investigating the stability of the imaging system of x-ray computed tomography

    International Nuclear Information System (INIS)

    Sun, Wenjuan; Brown, Stephen; Flay, Nadia; McCarthy, Michael; McBride, John

    2016-01-01

    The use of x-ray computed tomography for dimensional measurements associated with engineering applications has flourished in recent years. However, error sources associated with the technology are not well understood. In this paper, a novel two-sphere reference sample has been developed and used to investigate the stability of the imaging system that consists of an x-ray tube and a detector. In contrast with other research work reported, this work considered relative positional variation along the x -, y - and z -axes. This sample is a significant improvement over the one sphere sample proposed previously, which can only be used to observe the stability of the imaging system along x - and y -axes. Temperature variations of different parts of the system have been monitored and the relationship between temperature variations and x-ray image stability has been studied. Other effects that may also influence the stability of the imaging system have been discussed. The proposed reference sample and testing method are transferable to other types of x-ray computed tomography systems, for example, systems with transmission targets and systems with sub-micrometre focal spots. (paper)

  12. Decision-making and sampling size effect

    OpenAIRE

    Ismariah Ahmad; Rohana Abd Rahman; Roda Jean-Marc; Lim Hin Fui; Mohd Parid Mamat

    2010-01-01

    Sound decision-making requires quality information. Poor information does not help in decision making. Among the sources of low quality information, an important cause is inadequate and inappropriate sampling. In this paper we illustrate the case of information collected on timber prices.

  13. Fine focal spot size improves image quality in computed tomography abdomen and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Goh, Yin P.; Low, Keat; Kuganesan, Ahilan [Monash Health, Diagnostic Imaging Department, 246, Clayton Road, Clayton, Victoria (Australia); Lau, Kenneth K. [Monash Health, Diagnostic Imaging Department, 246, Clayton Road, Clayton, Victoria (Australia); Monash University, Department of Medicine, Faculty of Medicine, Nursing and Health Sciences, Victoria (Australia); Buchan, Kevin [Philips Healthcare, Clinical Science, PO Box 312, Mont Albert, Victoria (Australia); Oh, Lawrence Chia Wei [Flinders Medical Centre, Division of Medical Imaging, Bedford Park South (Australia); Huynh, Minh [Swinburne University, Department of Statistics, Data Science and Epidemiology, School of Health Sciences, Faculty of Health, Arts and Design, Hawthorn (Australia)

    2016-12-15

    To compare the image quality between fine focal spot size (FFSS) and standard focal spot size (SFSS) in computed tomography of the abdomen and pelvis (CTAP) This retrospective review included all consecutive adult patients undergoing contrast-enhanced CTAP between June and September 2014. Two blinded radiologists assessed the margin clarity of the abdominal viscera and the detected lesions using a five-point grading scale. Cohen's kappa test was used to examine the inter-observer reliability between the two reviewers for organ margin clarity. Mann-Whitney U testing was utilised to assess the statistical difference of the organ and lesion margin clarity. 100 consecutive CTAPs were recruited. 52 CTAPs were examined with SFSS of 1.1 x 1.2 mm and 48 CTAPs were examined with FFSS of 0.6 x 0.7 mm. Results showed that there was substantial agreement for organ margin clarity (mean κ = 0.759, p < 0.001) among the reviewers. FFSS produces images with clearer organ margins (U = 76194.0, p < 0.001, r = 0.523) and clearer lesion margins (U = 239, p = 0.052, r = 0.269). FFSS CTAP improves image quality in terms of better organ and lesion margin clarity. Fine focus CT scanning is a novel technique that may be applied in routine CTAP imaging. (orig.)

  14. Effect of sample matrix composition on INAA sample weights, measurement precisions, limits of detection, and optimum conditions

    International Nuclear Information System (INIS)

    Guinn, V.P.; Nakazawa, L.; Leslie, J.

    1984-01-01

    The instrumental neutron activation analysis (INAA) Advance Prediction Computer Program (APCP) is extremely useful in guiding one to optimum subsequent experimental analyses of samples of all types of matrices. By taking into account the contributions to the cumulative Compton-continuum levels from all significant induced gamma-emitting radionuclides, it provides good INAA advance estimates of detectable photopeaks, measurement precisions, concentration lower limits of detection (LOD's) and optimum irradiation/decay/counting conditions - as well as of the very important maximum allowable sample size for each set of conditions calculated. The usefulness and importance of the four output parameters cited in the title are discussed using the INAA APCP outputs for NBS SRM-1632 Coal as the example

  15. A contemporary decennial global sample of changing agricultural field sizes

    Science.gov (United States)

    White, E.; Roy, D. P.

    2011-12-01

    In the last several hundred years agriculture has caused significant human induced Land Cover Land Use Change (LCLUC) with dramatic cropland expansion and a marked increase in agricultural productivity. The size of agricultural fields is a fundamental description of rural landscapes and provides an insight into the drivers of rural LCLUC. Increasing field sizes cause a subsequent decrease in the number of fields and therefore decreased landscape spatial complexity with impacts on biodiversity, habitat, soil erosion, plant-pollinator interactions, diffusion of disease pathogens and pests, and loss or degradation in buffers to nutrient, herbicide and pesticide flows. In this study, globally distributed locations with significant contemporary field size change were selected guided by a global map of agricultural yield and literature review and were selected to be representative of different driving forces of field size change (associated with technological innovation, socio-economic conditions, government policy, historic patterns of land cover land use, and environmental setting). Seasonal Landsat data acquired on a decadal basis (for 1980, 1990, 2000 and 2010) were used to extract field boundaries and the temporal changes in field size quantified and their causes discussed.

  16. The effects of preparation, shipment and ageing on the Pu elemental assay results of milligram-sized samples

    International Nuclear Information System (INIS)

    Berger, J.; Doubek, N.; Jammet, G.; Aigner, H.; Bagliano, G.; Donohue, D.; Kuhn, E.

    1994-02-01

    Specialized procedures have been implemented for the sampling of Pu-containing materials such as Pu nitrate, oxide or mixed oxide in States which have not yet approved type B(U) shipment containers for the air-shipment of gram-sized quantities of Pu. In such cases, it it necessary to prepare samples for shipment which contain only milligram quantities of Pu dried from solution in penicillin vials. Potential problems due to flaking-off during shipment could affect the recovery of Pu at the analytical laboratory. Therefore, a series of tests was performed with synthetic Pu nitrated, and mixed U, Pu nitrated samples to test the effectiveness of the evaporation and recovery procedures. Results of these tests as well as experience with actual inspection samples are presented, showing conclusively that the existing procedures are satisfactory. (author). 11 refs, 6 figs, 8 tabs

  17. Analytical solutions to sampling effects in drop size distribution measurements during stationary rainfall: Estimation of bulk rainfall variables

    NARCIS (Netherlands)

    Uijlenhoet, R.; Porrà, J.M.; Sempere Torres, D.; Creutin, J.D.

    2006-01-01

    A stochastic model of the microstructure of rainfall is used to derive explicit expressions for the magnitude of the sampling fluctuations in rainfall properties estimated from raindrop size measurements in stationary rainfall. The model is a marked point process, in which the points represent the

  18. Investigating effects of sample pretreatment on protein stability using size-exclusion chromatography and high-resolution continuum source atomic absorption spectrometry.

    Science.gov (United States)

    Rakow, Tobias; El Deeb, Sami; Hahne, Thomas; El-Hady, Deia Abd; AlBishri, Hassan M; Wätzig, Hermann

    2014-09-01

    In this study, size-exclusion chromatography and high-resolution atomic absorption spectrometry methods have been developed and evaluated to test the stability of proteins during sample pretreatment. This especially includes different storage conditions but also adsorption before or even during the chromatographic process. For the development of the size exclusion method, a Biosep S3000 5 μm column was used for investigating a series of representative model proteins, namely bovine serum albumin, ovalbumin, monoclonal immunoglobulin G antibody, and myoglobin. Ambient temperature storage was found to be harmful to all model proteins, whereas short-term storage up to 14 days could be done in an ordinary refrigerator. Freezing the protein solutions was always complicated and had to be evaluated for each protein in the corresponding solvent. To keep the proteins in their native state a gentle freezing temperature should be chosen, hence liquid nitrogen should be avoided. Furthermore, a high-resolution continuum source atomic absorption spectrometry method was developed to observe the adsorption of proteins on container material and chromatographic columns. Adsorption to any container led to a sample loss and lowered the recovery rates. During the pretreatment and high-performance size-exclusion chromatography, adsorption caused sample losses of up to 33%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. A sampling-based computational strategy for the representation of epistemic uncertainty in model predictions with evidence theory.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, J. D. (Prostat, Mesa, AZ); Oberkampf, William Louis; Helton, Jon Craig (Arizona State University, Tempe, AZ); Storlie, Curtis B. (North Carolina State University, Raleigh, NC)

    2006-10-01

    Evidence theory provides an alternative to probability theory for the representation of epistemic uncertainty in model predictions that derives from epistemic uncertainty in model inputs, where the descriptor epistemic is used to indicate uncertainty that derives from a lack of knowledge with respect to the appropriate values to use for various inputs to the model. The potential benefit, and hence appeal, of evidence theory is that it allows a less restrictive specification of uncertainty than is possible within the axiomatic structure on which probability theory is based. Unfortunately, the propagation of an evidence theory representation for uncertainty through a model is more computationally demanding than the propagation of a probabilistic representation for uncertainty, with this difficulty constituting a serious obstacle to the use of evidence theory in the representation of uncertainty in predictions obtained from computationally intensive models. This presentation describes and illustrates a sampling-based computational strategy for the representation of epistemic uncertainty in model predictions with evidence theory. Preliminary trials indicate that the presented strategy can be used to propagate uncertainty representations based on evidence theory in analysis situations where naive sampling-based (i.e., unsophisticated Monte Carlo) procedures are impracticable due to computational cost.

  20. Patient size and x-ray technique factors in head computed tomography examinations. II. Image quality

    International Nuclear Information System (INIS)

    Huda, Walter; Lieberman, Kristin A.; Chang, Jack; Roskopf, Marsha L.

    2004-01-01

    We investigated how patient head characteristics, as well as the choice of x-ray technique factors, affect lesion contrast and noise values in computed tomography (CT) images. Head sizes and mean Hounsfield unit (HU) values were obtained from head CT images for five classes of patients ranging from the newborn to adults. X-ray spectra with tube voltages ranging from 80 to 140 kV were used to compute the average photon energy, and energy fluence, transmitted through the heads of patients of varying size. Image contrast, and the corresponding contrast to noise ratios (CNRs), were determined for lesions of fat, muscle, and iodine relative to a uniform water background. Maintaining a constant image CNR for each lesion, the patient energy imparted was also computed to identify the x-ray tube voltage that minimized the radiation dose. For adults, increasing the tube voltage from 80 to 140 kV changed the iodine HU from 2.62x10 5 to 1.27x10 5 , the fat HU from -138 to -108, and the muscle HU from 37.1 to 33.0. Increasing the x-ray tube voltage from 80 to 140 kV increased the percentage energy fluence transmission by up to a factor of 2. For a fixed x-ray tube voltage, the percentage transmitted energy fluence in adults was more than a factor of 4 lower than for newborns. For adults, increasing the x-ray tube voltage from 80 to 140 kV improved the CNR for muscle lesions by 130%, for fat lesions by a factor of 2, and for iodine lesions by 25%. As the size of the patient increased from newborn to adults, lesion CNR was reduced by about a factor of 2. The mAs value can be reduced by 80% when scanning newborns while maintaining the same lesion CNR as for adults. Maintaining the CNR of an iodine lesion at a constant level, use of 140 kV increases the energy imparted to an adult patient by nearly a factor of 3.5 in comparison to 80 kV. For fat and muscle lesions, raising the x-ray tube voltage from 80 to 140 kV at a constant CNR increased the patient dose by 37% and 7

  1. The influence of sampling unit size and spatial arrangement patterns on neighborhood-based spatial structure analyses of forest stands

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H.; Zhang, G.; Hui, G.; Li, Y.; Hu, Y.; Zhao, Z.

    2016-07-01

    Aim of study: Neighborhood-based stand spatial structure parameters can quantify and characterize forest spatial structure effectively. How these neighborhood-based structure parameters are influenced by the selection of different numbers of nearest-neighbor trees is unclear, and there is some disagreement in the literature regarding the appropriate number of nearest-neighbor trees to sample around reference trees. Understanding how to efficiently characterize forest structure is critical for forest management. Area of study: Multi-species uneven-aged forests of Northern China. Material and methods: We simulated stands with different spatial structural characteristics and systematically compared their structure parameters when two to eight neighboring trees were selected. Main results: Results showed that values of uniform angle index calculated in the same stand were different with different sizes of structure unit. When tree species and sizes were completely randomly interspersed, different numbers of neighbors had little influence on mingling and dominance indices. Changes of mingling or dominance indices caused by different numbers of neighbors occurred when the tree species or size classes were not randomly interspersed and their changing characteristics can be detected according to the spatial arrangement patterns of tree species and sizes. Research highlights: The number of neighboring trees selected for analyzing stand spatial structure parameters should be fixed. We proposed that the four-tree structure unit is the best compromise between sampling accuracy and costs for practical forest management. (Author)

  2. Sampling and sensitivity analyses tools (SaSAT for computational modelling

    Directory of Open Access Journals (Sweden)

    Wilson David P

    2008-02-01

    Full Text Available Abstract SaSAT (Sampling and Sensitivity Analysis Tools is a user-friendly software package for applying uncertainty and sensitivity analyses to mathematical and computational models of arbitrary complexity and context. The toolbox is built in Matlab®, a numerical mathematical software package, and utilises algorithms contained in the Matlab® Statistics Toolbox. However, Matlab® is not required to use SaSAT as the software package is provided as an executable file with all the necessary supplementary files. The SaSAT package is also designed to work seamlessly with Microsoft Excel but no functionality is forfeited if that software is not available. A comprehensive suite of tools is provided to enable the following tasks to be easily performed: efficient and equitable sampling of parameter space by various methodologies; calculation of correlation coefficients; regression analysis; factor prioritisation; and graphical output of results, including response surfaces, tornado plots, and scatterplots. Use of SaSAT is exemplified by application to a simple epidemic model. To our knowledge, a number of the methods available in SaSAT for performing sensitivity analyses have not previously been used in epidemiological modelling and their usefulness in this context is demonstrated.

  3. Perspective: Size selected clusters for catalysis and electrochemistry

    Science.gov (United States)

    Halder, Avik; Curtiss, Larry A.; Fortunelli, Alessandro; Vajda, Stefan

    2018-03-01

    Size-selected clusters containing a handful of atoms may possess noble catalytic properties different from nano-sized or bulk catalysts. Size- and composition-selected clusters can also serve as models of the catalytic active site, where an addition or removal of a single atom can have a dramatic effect on their activity and selectivity. In this perspective, we provide an overview of studies performed under both ultra-high vacuum and realistic reaction conditions aimed at the interrogation, characterization, and understanding of the performance of supported size-selected clusters in heterogeneous and electrochemical reactions, which address the effects of cluster size, cluster composition, cluster-support interactions, and reaction conditions, the key parameters for the understanding and control of catalyst functionality. Computational modeling based on density functional theory sampling of local minima and energy barriers or ab initio molecular dynamics simulations is an integral part of this research by providing fundamental understanding of the catalytic processes at the atomic level, as well as by predicting new materials compositions which can be validated in experiments. Finally, we discuss approaches which aim at the scale up of the production of well-defined clusters for use in real world applications.

  4. A comparison of fitness-case sampling methods for genetic programming

    Science.gov (United States)

    Martínez, Yuliana; Naredo, Enrique; Trujillo, Leonardo; Legrand, Pierrick; López, Uriel

    2017-11-01

    Genetic programming (GP) is an evolutionary computation paradigm for automatic program induction. GP has produced impressive results but it still needs to overcome some practical limitations, particularly its high computational cost, overfitting and excessive code growth. Recently, many researchers have proposed fitness-case sampling methods to overcome some of these problems, with mixed results in several limited tests. This paper presents an extensive comparative study of four fitness-case sampling methods, namely: Interleaved Sampling, Random Interleaved Sampling, Lexicase Selection and Keep-Worst Interleaved Sampling. The algorithms are compared on 11 symbolic regression problems and 11 supervised classification problems, using 10 synthetic benchmarks and 12 real-world data-sets. They are evaluated based on test performance, overfitting and average program size, comparing them with a standard GP search. Comparisons are carried out using non-parametric multigroup tests and post hoc pairwise statistical tests. The experimental results suggest that fitness-case sampling methods are particularly useful for difficult real-world symbolic regression problems, improving performance, reducing overfitting and limiting code growth. On the other hand, it seems that fitness-case sampling cannot improve upon GP performance when considering supervised binary classification.

  5. Sample size and number of outcome measures of veterinary randomised controlled trials of pharmaceutical interventions funded by different sources, a cross-sectional study.

    Science.gov (United States)

    Wareham, K J; Hyde, R M; Grindlay, D; Brennan, M L; Dean, R S

    2017-10-04

    Randomised controlled trials (RCTs) are a key component of the veterinary evidence base. Sample sizes and defined outcome measures are crucial components of RCTs. To describe the sample size and number of outcome measures of veterinary RCTs either funded by the pharmaceutical industry or not, published in 2011. A structured search of PubMed identified RCTs examining the efficacy of pharmaceutical interventions. Number of outcome measures, number of animals enrolled per trial, whether a primary outcome was identified, and the presence of a sample size calculation were extracted from the RCTs. The source of funding was identified for each trial and groups compared on the above parameters. Literature searches returned 972 papers; 86 papers comprising 126 individual trials were analysed. The median number of outcomes per trial was 5.0; there were no significant differences across funding groups (p = 0.133). The median number of animals enrolled per trial was 30.0; this was similar across funding groups (p = 0.302). A primary outcome was identified in 40.5% of trials and was significantly more likely to be stated in trials funded by a pharmaceutical company. A very low percentage of trials reported a sample size calculation (14.3%). Failure to report primary outcomes, justify sample sizes and the reporting of multiple outcome measures was a common feature in all of the clinical trials examined in this study. It is possible some of these factors may be affected by the source of funding of the studies, but the influence of funding needs to be explored with a larger number of trials. Some veterinary RCTs provide a weak evidence base and targeted strategies are required to improve the quality of veterinary RCTs to ensure there is reliable evidence on which to base clinical decisions.

  6. On stochastic error and computational efficiency of the Markov Chain Monte Carlo method

    KAUST Repository

    Li, Jun

    2014-01-01

    In Markov Chain Monte Carlo (MCMC) simulations, thermal equilibria quantities are estimated by ensemble average over a sample set containing a large number of correlated samples. These samples are selected in accordance with the probability distribution function, known from the partition function of equilibrium state. As the stochastic error of the simulation results is significant, it is desirable to understand the variance of the estimation by ensemble average, which depends on the sample size (i.e., the total number of samples in the set) and the sampling interval (i.e., cycle number between two consecutive samples). Although large sample sizes reduce the variance, they increase the computational cost of the simulation. For a given CPU time, the sample size can be reduced greatly by increasing the sampling interval, while having the corresponding increase in variance be negligible if the original sampling interval is very small. In this work, we report a few general rules that relate the variance with the sample size and the sampling interval. These results are observed and confirmed numerically. These variance rules are derived for theMCMCmethod but are also valid for the correlated samples obtained using other Monte Carlo methods. The main contribution of this work includes the theoretical proof of these numerical observations and the set of assumptions that lead to them. © 2014 Global-Science Press.

  7. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  8. Sampling for quality assurance of grading decisions in diabetic retinopathy screening: designing the system to detect errors.

    Science.gov (United States)

    Slattery, Jim

    2005-01-01

    To evaluate various designs for a quality assurance system to detect and control human errors in a national screening programme for diabetic retinopathy. A computer simulation was performed of some possible ways of sampling the referral decisions made during grading and of different criteria for initiating more intensive QA investigations. The effectiveness of QA systems was assessed by the ability to detect a grader making occasional errors in referral. Substantial QA sample sizes are needed to ensure against inappropriate failure to refer. Detection of a grader who failed to refer one in ten cases can be achieved with a probability of 0.58 using an annual sample size of 300 and 0.77 using a sample size of 500. An unmasked verification of a sample of non-referrals by a specialist is the most effective method of internal QA for the diabetic retinopathy screening programme. Preferential sampling of those with some degree of disease may improve the efficiency of the system.

  9. Young Children's Computer Skills Development from Kindergarten to Third Grade

    Science.gov (United States)

    Sackes, Mesut; Trundle, Kathy Cabe; Bell, Randy L.

    2011-01-01

    This investigation explores young children's computer skills development from kindergarten to third grade using the Early Childhood Longitudinal Study-Kindergarten (ECLS-K) dataset. The sample size of the study was 8642 children. Latent growth curve modeling analysis was used as an analytical tool to examine the development of children's computer…

  10. COED Transactions, Vol. X, No. 10, October 1978. Simulation of a Sampled-Data System on a Hybrid Computer.

    Science.gov (United States)

    Mitchell, Eugene E., Ed.

    The simulation of a sampled-data system is described that uses a full parallel hybrid computer. The sampled data system simulated illustrates the proportional-integral-derivative (PID) discrete control of a continuous second-order process representing a stirred-tank. The stirred-tank is simulated using continuous analog components, while PID…

  11. Numerical sedimentation particle-size analysis using the Discrete Element Method

    Science.gov (United States)

    Bravo, R.; Pérez-Aparicio, J. L.; Gómez-Hernández, J. J.

    2015-12-01

    Sedimentation tests are widely used to determine the particle size distribution of a granular sample. In this work, the Discrete Element Method interacts with the simulation of flow using the well known one-way-coupling method, a computationally affordable approach for the time-consuming numerical simulation of the hydrometer, buoyancy and pipette sedimentation tests. These tests are used in the laboratory to determine the particle-size distribution of fine-grained aggregates. Five samples with different particle-size distributions are modeled by about six million rigid spheres projected on two-dimensions, with diameters ranging from 2.5 ×10-6 m to 70 ×10-6 m, forming a water suspension in a sedimentation cylinder. DEM simulates the particle's movement considering laminar flow interactions of buoyant, drag and lubrication forces. The simulation provides the temporal/spatial distributions of densities and concentrations of the suspension. The numerical simulations cannot replace the laboratory tests since they need the final granulometry as initial data, but, as the results show, these simulations can identify the strong and weak points of each method and eventually recommend useful variations and draw conclusions on their validity, aspects very difficult to achieve in the laboratory.

  12. Pb isotope analysis of ng size samples by TIMS equipped with a 1013 Ω resistor using a 207Pb-204Pb double spike

    NARCIS (Netherlands)

    Klaver, M.; Smeets, R.J.; Koornneef, J.M.; Davies, G.R.; Vroon, P.Z.

    2016-01-01

    The use of the double spike technique to correct for instrumental mass fractionation has yielded high precision results for lead isotope measurements by thermal ionisation mass spectrometry (TIMS), but the applicability to ng size Pb samples is hampered by the small size of the

  13. Rapid Sampling of Hydrogen Bond Networks for Computational Protein Design.

    Science.gov (United States)

    Maguire, Jack B; Boyken, Scott E; Baker, David; Kuhlman, Brian

    2018-05-08

    Hydrogen bond networks play a critical role in determining the stability and specificity of biomolecular complexes, and the ability to design such networks is important for engineering novel structures, interactions, and enzymes. One key feature of hydrogen bond networks that makes them difficult to rationally engineer is that they are highly cooperative and are not energetically favorable until the hydrogen bonding potential has been satisfied for all buried polar groups in the network. Existing computational methods for protein design are ill-equipped for creating these highly cooperative networks because they rely on energy functions and sampling strategies that are focused on pairwise interactions. To enable the design of complex hydrogen bond networks, we have developed a new sampling protocol in the molecular modeling program Rosetta that explicitly searches for sets of amino acid mutations that can form self-contained hydrogen bond networks. For a given set of designable residues, the protocol often identifies many alternative sets of mutations/networks, and we show that it can readily be applied to large sets of residues at protein-protein interfaces or in the interior of proteins. The protocol builds on a recently developed method in Rosetta for designing hydrogen bond networks that has been experimentally validated for small symmetric systems but was not extensible to many larger protein structures and complexes. The sampling protocol we describe here not only recapitulates previously validated designs with performance improvements but also yields viable hydrogen bond networks for cases where the previous method fails, such as the design of large, asymmetric interfaces relevant to engineering protein-based therapeutics.

  14. Assessment of bone biopsy needles for sample size, specimen quality and ease of use

    International Nuclear Information System (INIS)

    Roberts, C.C.; Liu, P.T.; Morrison, W.B.; Leslie, K.O.; Carrino, J.A.; Lozevski, J.L.

    2005-01-01

    To assess whether there are significant differences in ease of use and quality of samples among several bone biopsy needles currently available. Eight commonly used, commercially available bone biopsy needles of different gauges were evaluated. Each needle was used to obtain five consecutive samples from a lamb lumbar pedicle. Subjective assessment of ease of needle use, ease of sample removal from the needle and sample quality, before and after fixation, was graded on a 5-point scale. The number of attempts necessary to reach a 1 cm depth was recorded. Each biopsy specimen was measured in the gross state and after fixation. The RADI Bonopty 15 g and Kendall Monoject J-type 11 g needles were rated the easiest to use, while the Parallax Core-Assure 11 g and the Bard Ostycut 16 g were rated the most difficult. Parallax Core-Assure and Kendall Monoject needles had the highest quality specimen in the gross state; Cook Elson/Ackerman 14 g and Bard Ostycut 16 g needles yielded the lowest. The MD Tech without Trap-Lok 11 g needle had the highest quality core after fixation, while the Bard Ostycut 16 g had the lowest. There was a significant difference in pre-fixation sample length between needles (P<0.0001), despite acquiring all cores to a standard 1 cm depth. Core length and width decrease in size by an average of 28% and 42% after fixation. Bone biopsy needles vary significantly in performance. Detailed knowledge of the strengths and weaknesses of different needles is important to make an appropriate selection for each individual's practice. (orig.)

  15. X-Ray Computed Tomography: The First Step in Mars Sample Return Processing

    Science.gov (United States)

    Welzenbach, L. C.; Fries, M. D.; Grady, M. M.; Greenwood, R. C.; McCubbin, F. M.; Zeigler, R. A.; Smith, C. L.; Steele, A.

    2017-01-01

    The Mars 2020 rover mission will collect and cache samples from the martian surface for possible retrieval and subsequent return to Earth. If the samples are returned, that mission would likely present an opportunity to analyze returned Mars samples within a geologic context on Mars. In addition, it may provide definitive information about the existence of past or present life on Mars. Mars sample return presents unique challenges for the collection, containment, transport, curation and processing of samples [1] Foremost in the processing of returned samples are the closely paired considerations of life detection and Planetary Protection. In order to achieve Mars Sample Return (MSR) science goals, reliable analyses will depend on overcoming some challenging signal/noise-related issues where sparse martian organic compounds must be reliably analyzed against the contamination background. While reliable analyses will depend on initial clean acquisition and robust documentation of all aspects of developing and managing the cache [2], there needs to be a reliable sample handling and analysis procedure that accounts for a variety of materials which may or may not contain evidence of past or present martian life. A recent report [3] suggests that a defined set of measurements should be made to effectively inform both science and Planetary Protection, when applied in the context of the two competing null hypotheses: 1) that there is no detectable life in the samples; or 2) that there is martian life in the samples. The defined measurements would include a phased approach that would be accepted by the community to preserve the bulk of the material, but provide unambiguous science data that can be used and interpreted by various disciplines. Fore-most is the concern that the initial steps would ensure the pristine nature of the samples. Preliminary, non-invasive techniques such as computed X-ray tomography (XCT) have been suggested as the first method to interrogate and

  16. Selection of window sizes for optimizing occupational comfort and hygiene based on computational fluid dynamics and neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Stavrakakis, G.M.; Karadimou, D.P.; Zervas, P.L.; Markatos, N.C. [Computational Fluid Dynamics Unit, School of Chemical Engineering, National Technical University of Athens, Heroon Polytechniou 9, GR-15780 Athens (Greece); Sarimveis, H. [Unit of Process Control and Informatics, School of Chemical Engineering, National Technical University of Athens, Heroon Polytechniou 9, GR-15780 Athens (Greece)

    2011-02-15

    The present paper presents a novel computational method to optimize window sizes for thermal comfort and indoor air quality in naturally ventilated buildings. The methodology is demonstrated by means of a prototype case, which corresponds to a single-sided naturally ventilated apartment. Initially, the airflow in and around the building is simulated using a Computational Fluid Dynamics model. Local prevailing weather conditions are imposed in the CFD model as inlet boundary conditions. The produced airflow patterns are utilized to predict thermal comfort indices, i.e. the PMV and its modifications for non-air-conditioned buildings, as well as indoor air quality indices, such as ventilation effectiveness based on carbon dioxide and volatile organic compounds removal. Mean values of these indices (output/objective variables) within the occupied zone are calculated for different window sizes (input/design variables), to generate a database of input-output data pairs. The database is then used to train and validate Radial Basis Function Artificial Neural Network input-output ''meta-models''. The produced meta-models are used to formulate an optimization problem, which takes into account special constraints recommended by design guidelines. It is concluded that the proposed methodology determines appropriate windows architectural designs for pleasant and healthy indoor environments. (author)

  17. Exact sampling hardness of Ising spin models

    Science.gov (United States)

    Fefferman, B.; Foss-Feig, M.; Gorshkov, A. V.

    2017-09-01

    We study the complexity of classically sampling from the output distribution of an Ising spin model, which can be implemented naturally in a variety of atomic, molecular, and optical systems. In particular, we construct a specific example of an Ising Hamiltonian that, after time evolution starting from a trivial initial state, produces a particular output configuration with probability very nearly proportional to the square of the permanent of a matrix with arbitrary integer entries. In a similar spirit to boson sampling, the ability to sample classically from the probability distribution induced by time evolution under this Hamiltonian would imply unlikely complexity theoretic consequences, suggesting that the dynamics of such a spin model cannot be efficiently simulated with a classical computer. Physical Ising spin systems capable of achieving problem-size instances (i.e., qubit numbers) large enough so that classical sampling of the output distribution is classically difficult in practice may be achievable in the near future. Unlike boson sampling, our current results only imply hardness of exact classical sampling, leaving open the important question of whether a much stronger approximate-sampling hardness result holds in this context. The latter is most likely necessary to enable a convincing experimental demonstration of quantum supremacy. As referenced in a recent paper [A. Bouland, L. Mancinska, and X. Zhang, in Proceedings of the 31st Conference on Computational Complexity (CCC 2016), Leibniz International Proceedings in Informatics (Schloss Dagstuhl-Leibniz-Zentrum für Informatik, Dagstuhl, 2016)], our result completes the sampling hardness classification of two-qubit commuting Hamiltonians.

  18. Confidence intervals for population allele frequencies: the general case of sampling from a finite diploid population of any size.

    Science.gov (United States)

    Fung, Tak; Keenan, Kevin

    2014-01-01

    The estimation of population allele frequencies using sample data forms a central component of studies in population genetics. These estimates can be used to test hypotheses on the evolutionary processes governing changes in genetic variation among populations. However, existing studies frequently do not account for sampling uncertainty in these estimates, thus compromising their utility. Incorporation of this uncertainty has been hindered by the lack of a method for constructing confidence intervals containing the population allele frequencies, for the general case of sampling from a finite diploid population of any size. In this study, we address this important knowledge gap by presenting a rigorous mathematical method to construct such confidence intervals. For a range of scenarios, the method is used to demonstrate that for a particular allele, in order to obtain accurate estimates within 0.05 of the population allele frequency with high probability (> or = 95%), a sample size of > 30 is often required. This analysis is augmented by an application of the method to empirical sample allele frequency data for two populations of the checkerspot butterfly (Melitaea cinxia L.), occupying meadows in Finland. For each population, the method is used to derive > or = 98.3% confidence intervals for the population frequencies of three alleles. These intervals are then used to construct two joint > or = 95% confidence regions, one for the set of three frequencies for each population. These regions are then used to derive a > or = 95%% confidence interval for Jost's D, a measure of genetic differentiation between the two populations. Overall, the results demonstrate the practical utility of the method with respect to informing sampling design and accounting for sampling uncertainty in studies of population genetics, important for scientific hypothesis-testing and also for risk-based natural resource management.

  19. Confidence intervals for population allele frequencies: the general case of sampling from a finite diploid population of any size.

    Directory of Open Access Journals (Sweden)

    Tak Fung

    Full Text Available The estimation of population allele frequencies using sample data forms a central component of studies in population genetics. These estimates can be used to test hypotheses on the evolutionary processes governing changes in genetic variation among populations. However, existing studies frequently do not account for sampling uncertainty in these estimates, thus compromising their utility. Incorporation of this uncertainty has been hindered by the lack of a method for constructing confidence intervals containing the population allele frequencies, for the general case of sampling from a finite diploid population of any size. In this study, we address this important knowledge gap by presenting a rigorous mathematical method to construct such confidence intervals. For a range of scenarios, the method is used to demonstrate that for a particular allele, in order to obtain accurate estimates within 0.05 of the population allele frequency with high probability (> or = 95%, a sample size of > 30 is often required. This analysis is augmented by an application of the method to empirical sample allele frequency data for two populations of the checkerspot butterfly (Melitaea cinxia L., occupying meadows in Finland. For each population, the method is used to derive > or = 98.3% confidence intervals for the population frequencies of three alleles. These intervals are then used to construct two joint > or = 95% confidence regions, one for the set of three frequencies for each population. These regions are then used to derive a > or = 95%% confidence interval for Jost's D, a measure of genetic differentiation between the two populations. Overall, the results demonstrate the practical utility of the method with respect to informing sampling design and accounting for sampling uncertainty in studies of population genetics, important for scientific hypothesis-testing and also for risk-based natural resource management.

  20. Automatic sampling for unbiased and efficient stereological estimation using the proportionator in biological studies

    DEFF Research Database (Denmark)

    Gardi, Jonathan Eyal; Nyengaard, Jens Randel; Gundersen, Hans Jørgen Gottlieb

    2008-01-01

    Quantification of tissue properties is improved using the general proportionator sampling and estimation procedure: automatic image analysis and non-uniform sampling with probability proportional to size (PPS). The complete region of interest is partitioned into fields of view, and every field...... of view is given a weight (the size) proportional to the total amount of requested image analysis features in it. The fields of view sampled with known probabilities proportional to individual weight are the only ones seen by the observer who provides the correct count. Even though the image analysis...... cerebellum, total number of orexin positive neurons in transgenic mice brain, and estimating the absolute area and the areal fraction of β islet cells in dog pancreas.  The proportionator was at least eight times more efficient (precision and time combined) than traditional computer controlled sampling....

  1. Lot quality assurance sampling (LQAS) for monitoring a leprosy elimination program.

    Science.gov (United States)

    Gupte, M D; Narasimhamurthy, B

    1999-06-01

    In a statistical sense, prevalences of leprosy in different geographical areas can be called very low or rare. Conventional survey methods to monitor leprosy control programs, therefore, need large sample sizes, are expensive, and are time-consuming. Further, with the lowering of prevalence to the near-desired target level, 1 case per 10,000 population at national or subnational levels, the program administrator's concern will be shifted to smaller areas, e.g., districts, for assessment and, if needed, for necessary interventions. In this paper, Lot Quality Assurance Sampling (LQAS), a quality control tool in industry, is proposed to identify districts/regions having a prevalence of leprosy at or above a certain target level, e.g., 1 in 10,000. This technique can also be considered for identifying districts/regions at or below the target level of 1 per 10,000, i.e., areas where the elimination level is attained. For simulating various situations and strategies, a hypothetical computerized population of 10 million persons was created. This population mimics the actual population in terms of the empirical information on rural/urban distributions and the distribution of households by size for the state of Tamil Nadu, India. Various levels with respect to leprosy prevalence are created using this population. The distribution of the number of cases in the population was expected to follow the Poisson process, and this was also confirmed by examination. Sample sizes and corresponding critical values were computed using Poisson approximation. Initially, villages/towns are selected from the population and from each selected village/town households are selected using systematic sampling. Households instead of individuals are used as sampling units. This sampling procedure was simulated 1000 times in the computer from the base population. The results in four different prevalence situations meet the required limits of Type I error of 5% and 90% Power. It is concluded that

  2. Inert gases in a terra sample - Measurements in six grain-size fractions and two single particles from Lunar 20.

    Science.gov (United States)

    Heymann, D.; Lakatos, S.; Walton, J. R.

    1973-01-01

    Review of the results of inert gas measurements performed on six grain-size fractions and two single particles from four samples of Luna 20 material. Presented and discussed data include the inert gas contents, element and isotope systematics, radiation ages, and Ar-36/Ar-40 systematics.

  3. Computing exact Fourier series coefficients of IC rectilinear polygons from low-resolution fast Fourier coefficients

    Science.gov (United States)

    Scheibler, Robin; Hurley, Paul

    2012-03-01

    We present a novel, accurate and fast algorithm to obtain Fourier series coefficients from an IC layer whose description consists of rectilinear polygons on a plane, and how to implement it using off-the-shelf hardware components. Based on properties of Fourier calculus, we derive a relationship between the Discrete Fourier Transforms of the sampled mask transmission function and its continuous Fourier series coefficients. The relationship leads to a straightforward algorithm for computing the continuous Fourier series coefficients where one samples the mask transmission function, compute its discrete Fourier transform and applies a frequency-dependent multiplicative factor. The algorithm is guaranteed to yield the exact continuous Fourier series coefficients for any sampling representing the mask function exactly. Computationally, this leads to significant saving by allowing to choose the maximal such pixel size and reducing the fast Fourier transform size by as much, without compromising accuracy. In addition, the continuous Fourier series is free from aliasing and follows closely the physical model of Fourier optics. We show that in some cases this can make a significant difference, especially in modern very low pitch technology nodes.

  4. Personal computer control system for small size tandem accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Takayama, Hiroshi; Kawano, Kazuhiro; Shinozaki, Masataka [Nissin - High Voltage Co. Ltd., Kyoto (Japan)

    1996-12-01

    As the analysis apparatus using tandem accelerator has a lot of control parameter, numbers of control parts set on control panel are so many to make the panel more complex and its operativity worse. In order to improve these faults, development and design of a control system using personal computer for the control panel mainly constituted by conventional hardware parts were tried. Their predominant characteristics are shown as follows: (1) To make the control panel construction simpler and more compact, because the hardware device on the panel surface becomes the smallest limit as required by using a personal computer for man-machine interface. (2) To make control speed more rapid, because sequence control is closed within each block by driving accelerator system to each block and installing local station of the sequencer network at each block. (3) To make expandability larger, because of few improvement of the present hardware by interrupting the sequencer local station into the net and correcting image of the computer when increasing a new beamline. And, (4) to make control system cheaper, because of cheaper investment and easier programming by using the personal computer. (G.K.)

  5. Impact of cone-beam computed tomography on implant planning and on prediction of implant size

    International Nuclear Information System (INIS)

    Pedroso, Ludmila Assuncao de Mello; Silva, Maria Alves Garcia Santos; Garcia, Robson Rodrigues; Leles, Jose Luiz Rodrigues; Leles, Claudio Rodrigues

    2013-01-01

    The aim was to investigate the impact of cone-beam computed tomography (CBCT) on implant planning and on prediction of final implant size. Consecutive patients referred for implant treatment were submitted to clinical examination, panoramic (PAN) radiography and a CBCT exam. Initial planning of implant length and width was assessed based on clinical and PAN exams, and final planning, on CBCT exam to complement diagnosis. The actual dimensions of the implants placed during surgery were compared with those obtained during initial and final planning, using the McNemmar test (p 0.05). It was concluded that CBCT improves the ability of predicting the actual implant length and reduces inaccuracy in surgical dental implant planning. (author)

  6. Multistatic Array Sampling Scheme for Fast Near-Field Image Reconstruction

    Science.gov (United States)

    2016-01-01

    human-sized scene in 0.048sec− 0.101sec. Index Terms—Microwave imaging, multistatic radar, Fast Fourier Transform (FFT). I. INTRODUCTION Near-field...configuration, but its computational demands are extreme. Fast Fourier Transform (FFT) imaging has long been used to efficiently construct images sampled...with the block diagram depicted in Fig. 4. It is noted that the multistatic to monostatic correction is valid over a finite imaging domain. However, as

  7. Major- and trace elements in grain size fractions of the Apollo-17 core of the drilled sample 74001

    International Nuclear Information System (INIS)

    Kraehenbuehl, U.; Gunten, H.R. von; Jost, D.; Meyer, G.; Wegmueller, F.

    1980-01-01

    Two layers of a drill sample were examined, one from a depth of 38 cm and the other from 58 cm depth. Neutron activation analysis was used for one group of elements, and radiochemical analysis for another. Over a range of grain size from 36 to 450 μm, the trace elements U, Co, and La were found to uniformly distributed, as was iron. The top layer consistently showed a 5-8% higher content. The volatile trace elements Ge and Cd were found to be enriched in the smaller grain sizes. This contradicts previous assumptions of an enrichment of the more volatile elements in top layers owing to more rapid cooling of volcanic eruptions. (R.S.)

  8. Sampling surface and subsurface particle-size distributions in wadable gravel-and cobble-bed streams for analyses in sediment transport, hydraulics, and streambed monitoring

    Science.gov (United States)

    Kristin Bunte; Steven R. Abt

    2001-01-01

    This document provides guidance for sampling surface and subsurface sediment from wadable gravel-and cobble-bed streams. After a short introduction to streams types and classifications in gravel-bed rivers, the document explains the field and laboratory measurement of particle sizes and the statistical analysis of particle-size distributions. Analysis of particle...

  9. Generic Learning-Based Ensemble Framework for Small Sample Size Face Recognition in Multi-Camera Networks.

    Science.gov (United States)

    Zhang, Cuicui; Liang, Xuefeng; Matsuyama, Takashi

    2014-12-08

    Multi-camera networks have gained great interest in video-based surveillance systems for security monitoring, access control, etc. Person re-identification is an essential and challenging task in multi-camera networks, which aims to determine if a given individual has already appeared over the camera network. Individual recognition often uses faces as a trial and requires a large number of samples during the training phrase. This is difficult to fulfill due to the limitation of the camera hardware system and the unconstrained image capturing conditions. Conventional face recognition algorithms often encounter the "small sample size" (SSS) problem arising from the small number of training samples compared to the high dimensionality of the sample space. To overcome this problem, interest in the combination of multiple base classifiers has sparked research efforts in ensemble methods. However, existing ensemble methods still open two questions: (1) how to define diverse base classifiers from the small data; (2) how to avoid the diversity/accuracy dilemma occurring during ensemble. To address these problems, this paper proposes a novel generic learning-based ensemble framework, which augments the small data by generating new samples based on a generic distribution and introduces a tailored 0-1 knapsack algorithm to alleviate the diversity/accuracy dilemma. More diverse base classifiers can be generated from the expanded face space, and more appropriate base classifiers are selected for ensemble. Extensive experimental results on four benchmarks demonstrate the higher ability of our system to cope with the SSS problem compared to the state-of-the-art system.

  10. [A comparison of convenience sampling and purposive sampling].

    Science.gov (United States)

    Suen, Lee-Jen Wu; Huang, Hui-Man; Lee, Hao-Hsien

    2014-06-01

    Convenience sampling and purposive sampling are two different sampling methods. This article first explains sampling terms such as target population, accessible population, simple random sampling, intended sample, actual sample, and statistical power analysis. These terms are then used to explain the difference between "convenience sampling" and purposive sampling." Convenience sampling is a non-probabilistic sampling technique applicable to qualitative or quantitative studies, although it is most frequently used in quantitative studies. In convenience samples, subjects more readily accessible to the researcher are more likely to be included. Thus, in quantitative studies, opportunity to participate is not equal for all qualified individuals in the target population and study results are not necessarily generalizable to this population. As in all quantitative studies, increasing the sample size increases the statistical power of the convenience sample. In contrast, purposive sampling is typically used in qualitative studies. Researchers who use this technique carefully select subjects based on study purpose with the expectation that each participant will provide unique and rich information of value to the study. As a result, members of the accessible population are not interchangeable and sample size is determined by data saturation not by statistical power analysis.

  11. Laboratory and exterior decay of wood plastic composite boards: voids analysis and computed tomography

    Science.gov (United States)

    Grace Sun; Rebecca E. Ibach; Meghan Faillace; Marek Gnatowski; Jessie A. Glaeser; John Haight

    2016-01-01

    After exposure in the field and laboratory soil block culture testing, the void content of wood–plastic composite (WPC) decking boards was compared to unexposed samples. A void volume analysis was conducted based on calculations of sample density and from micro-computed tomography (microCT) data. It was found that reference WPC contains voids of different sizes from...

  12. Dose computation of Ti activated products for its qualification as a material for the sample holder in FBTR

    International Nuclear Information System (INIS)

    Ashok Kumar, G.V.S.; Kumar, R.; Venkatasubramani, C.R.; Acharya, R.; Reddy, A.V.R.

    2014-01-01

    Development of a Fast flux experimental facility with a sample holder facility in FBTR has been envisaged to carry out the studies on i) fast neutron activation analysis and ii) fission studies. This paper describes the facility in detail and dose computations that are to be generated due to long irradiation of the material of the sample holder i.e. titanium. (author)

  13. Assessment of the accuracy of portion size reports using computer-based food photographs aids in the development of an automated self-administered 24-hour recall.

    Science.gov (United States)

    Subar, Amy F; Crafts, Jennifer; Zimmerman, Thea Palmer; Wilson, Michael; Mittl, Beth; Islam, Noemi G; McNutt, Suzanne; Potischman, Nancy; Buday, Richard; Hull, Stephen G; Baranowski, Tom; Guenther, Patricia M; Willis, Gordon; Tapia, Ramsey; Thompson, Frances E

    2010-01-01

    To assess the accuracy of portion-size estimates and participant preferences using various presentations of digital images. Two observational feeding studies were conducted. In both, each participant selected and consumed foods for breakfast and lunch, buffet style, serving themselves portions of nine foods representing five forms (eg, amorphous, pieces). Serving containers were weighed unobtrusively before and after selection as was plate waste. The next day, participants used a computer software program to select photographs representing portion sizes of foods consumed the previous day. Preference information was also collected. In Study 1 (n=29), participants were presented with four different types of images (aerial photographs, angled photographs, images of mounds, and household measures) and two types of screen presentations (simultaneous images vs an empty plate that filled with images of food portions when clicked). In Study 2 (n=20), images were presented in two ways that varied by size (large vs small) and number (4 vs 8). Convenience sample of volunteers of varying background in an office setting. Repeated-measures analysis of variance of absolute differences between actual and reported portions sizes by presentation methods. Accuracy results were largely not statistically significant, indicating that no one image type was most accurate. Accuracy results indicated the use of eight vs four images was more accurate. Strong participant preferences supported presenting simultaneous vs sequential images. These findings support the use of aerial photographs in the automated self-administered 24-hour recall. For some food forms, images of mounds or household measures are as accurate as images of food and, therefore, are a cost-effective alternative to photographs of foods. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  14. Sampling free energy surfaces as slices by combining umbrella sampling and metadynamics.

    Science.gov (United States)

    Awasthi, Shalini; Kapil, Venkat; Nair, Nisanth N

    2016-06-15

    Metadynamics (MTD) is a very powerful technique to sample high-dimensional free energy landscapes, and due to its self-guiding property, the method has been successful in studying complex reactions and conformational changes. MTD sampling is based on filling the free energy basins by biasing potentials and thus for cases with flat, broad, and unbound free energy wells, the computational time to sample them becomes very large. To alleviate this problem, we combine the standard Umbrella Sampling (US) technique with MTD to sample orthogonal collective variables (CVs) in a simultaneous way. Within this scheme, we construct the equilibrium distribution of CVs from biased distributions obtained from independent MTD simulations with umbrella potentials. Reweighting is carried out by a procedure that combines US reweighting and Tiwary-Parrinello MTD reweighting within the Weighted Histogram Analysis Method (WHAM). The approach is ideal for a controlled sampling of a CV in a MTD simulation, making it computationally efficient in sampling flat, broad, and unbound free energy surfaces. This technique also allows for a distributed sampling of a high-dimensional free energy surface, further increasing the computational efficiency in sampling. We demonstrate the application of this technique in sampling high-dimensional surface for various chemical reactions using ab initio and QM/MM hybrid molecular dynamics simulations. Further, to carry out MTD bias reweighting for computing forward reaction barriers in ab initio or QM/MM simulations, we propose a computationally affordable approach that does not require recrossing trajectories. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. 7 CFR 52.775 - Sample unit size.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... extraneous material—The total contents of each container in the sample. Factors of Quality ...

  16. A Model Based Approach to Sample Size Estimation in Recent Onset Type 1 Diabetes

    Science.gov (United States)

    Bundy, Brian; Krischer, Jeffrey P.

    2016-01-01

    The area under the curve C-peptide following a 2-hour mixed meal tolerance test from 481 individuals enrolled on 5 prior TrialNet studies of recent onset type 1 diabetes from baseline to 12 months after enrollment were modelled to produce estimates of its rate of loss and variance. Age at diagnosis and baseline C-peptide were found to be significant predictors and adjusting for these in an ANCOVA resulted in estimates with lower variance. Using these results as planning parameters for new studies results in a nearly 50% reduction in the target sample size. The modelling also produces an expected C-peptide that can be used in Observed vs. Expected calculations to estimate the presumption of benefit in ongoing trials. PMID:26991448

  17. RNAdualPF: software to compute the dual partition function with sample applications in molecular evolution theory.

    Science.gov (United States)

    Garcia-Martin, Juan Antonio; Bayegan, Amir H; Dotu, Ivan; Clote, Peter

    2016-10-19

    RNA inverse folding is the problem of finding one or more sequences that fold into a user-specified target structure s 0 , i.e. whose minimum free energy secondary structure is identical to the target s 0 . Here we consider the ensemble of all RNA sequences that have low free energy with respect to a given target s 0 . We introduce the program RNAdualPF, which computes the dual partition function Z ∗ , defined as the sum of Boltzmann factors exp(-E(a,s 0 )/RT) of all RNA nucleotide sequences a compatible with target structure s 0 . Using RNAdualPF, we efficiently sample RNA sequences that approximately fold into s 0 , where additionally the user can specify IUPAC sequence constraints at certain positions, and whether to include dangles (energy terms for stacked, single-stranded nucleotides). Moreover, since we also compute the dual partition function Z ∗ (k) over all sequences having GC-content k, the user can require that all sampled sequences have a precise, specified GC-content. Using Z ∗ , we compute the dual expected energy 〈E ∗ 〉, and use it to show that natural RNAs from the Rfam 12.0 database have higher minimum free energy than expected, thus suggesting that functional RNAs are under evolutionary pressure to be only marginally thermodynamically stable. We show that C. elegans precursor microRNA (pre-miRNA) is significantly non-robust with respect to mutations, by comparing the robustness of each wild type pre-miRNA sequence with 2000 [resp. 500] sequences of the same GC-content generated by RNAdualPF, which approximately [resp. exactly] fold into the wild type target structure. We confirm and strengthen earlier findings that precursor microRNAs and bacterial small noncoding RNAs display plasticity, a measure of structural diversity. We describe RNAdualPF, which rapidly computes the dual partition function Z ∗ and samples sequences having low energy with respect to a target structure, allowing sequence constraints and specified GC

  18. Optimizing trial design in pharmacogenetics research: comparing a fixed parallel group, group sequential, and adaptive selection design on sample size requirements.

    Science.gov (United States)

    Boessen, Ruud; van der Baan, Frederieke; Groenwold, Rolf; Egberts, Antoine; Klungel, Olaf; Grobbee, Diederick; Knol, Mirjam; Roes, Kit

    2013-01-01

    Two-stage clinical trial designs may be efficient in pharmacogenetics research when there is some but inconclusive evidence of effect modification by a genomic marker. Two-stage designs allow to stop early for efficacy or futility and can offer the additional opportunity to enrich the study population to a specific patient subgroup after an interim analysis. This study compared sample size requirements for fixed parallel group, group sequential, and adaptive selection designs with equal overall power and control of the family-wise type I error rate. The designs were evaluated across scenarios that defined the effect sizes in the marker positive and marker negative subgroups and the prevalence of marker positive patients in the overall study population. Effect sizes were chosen to reflect realistic planning scenarios, where at least some effect is present in the marker negative subgroup. In addition, scenarios were considered in which the assumed 'true' subgroup effects (i.e., the postulated effects) differed from those hypothesized at the planning stage. As expected, both two-stage designs generally required fewer patients than a fixed parallel group design, and the advantage increased as the difference between subgroups increased. The adaptive selection design added little further reduction in sample size, as compared with the group sequential design, when the postulated effect sizes were equal to those hypothesized at the planning stage. However, when the postulated effects deviated strongly in favor of enrichment, the comparative advantage of the adaptive selection design increased, which precisely reflects the adaptive nature of the design. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Signal Sampling for Efficient Sparse Representation of Resting State FMRI Data

    Science.gov (United States)

    Ge, Bao; Makkie, Milad; Wang, Jin; Zhao, Shijie; Jiang, Xi; Li, Xiang; Lv, Jinglei; Zhang, Shu; Zhang, Wei; Han, Junwei; Guo, Lei; Liu, Tianming

    2015-01-01

    As the size of brain imaging data such as fMRI grows explosively, it provides us with unprecedented and abundant information about the brain. How to reduce the size of fMRI data but not lose much information becomes a more and more pressing issue. Recent literature studies tried to deal with it by dictionary learning and sparse representation methods, however, their computation complexities are still high, which hampers the wider application of sparse representation method to large scale fMRI datasets. To effectively address this problem, this work proposes to represent resting state fMRI (rs-fMRI) signals of a whole brain via a statistical sampling based sparse representation. First we sampled the whole brain’s signals via different sampling methods, then the sampled signals were aggregate into an input data matrix to learn a dictionary, finally this dictionary was used to sparsely represent the whole brain’s signals and identify the resting state networks. Comparative experiments demonstrate that the proposed signal sampling framework can speed-up by ten times in reconstructing concurrent brain networks without losing much information. The experiments on the 1000 Functional Connectomes Project further demonstrate its effectiveness and superiority. PMID:26646924

  20. Probability Sampling Method for a Hidden Population Using Respondent-Driven Sampling: Simulation for Cancer Survivors.

    Science.gov (United States)

    Jung, Minsoo

    2015-01-01

    When there is no sampling frame within a certain group or the group is concerned that making its population public would bring social stigma, we say the population is hidden. It is difficult to approach this kind of population survey-methodologically because the response rate is low and its members are not quite honest with their responses when probability sampling is used. The only alternative known to address the problems caused by previous methods such as snowball sampling is respondent-driven sampling (RDS), which was developed by Heckathorn and his colleagues. RDS is based on a Markov chain, and uses the social network information of the respondent. This characteristic allows for probability sampling when we survey a hidden population. We verified through computer simulation whether RDS can be used on a hidden population of cancer survivors. According to the simulation results of this thesis, the chain-referral sampling of RDS tends to minimize as the sample gets bigger, and it becomes stabilized as the wave progresses. Therefore, it shows that the final sample information can be completely independent from the initial seeds if a certain level of sample size is secured even if the initial seeds were selected through convenient sampling. Thus, RDS can be considered as an alternative which can improve upon both key informant sampling and ethnographic surveys, and it needs to be utilized for various cases domestically as well.