WorldWideScience

Sample records for sample radon testing

  1. The Department of Energy's radon testing program

    International Nuclear Information System (INIS)

    Scott, H.L.; Dudney, C.S.; Wilson, D.L.; Gammage, R.B.

    1993-01-01

    The US Department of Energy recently completed an initial survey of indoor radon in its buildings in response to Public Law 100--551, the Indoor Radon Abatement Act of 1988. Other federal agencies have also conducted radon surveys. This paper presents an overview of the results from radon testing of several thousand buildings ranging from 100 m 2 to over 10,000 M 2 in size. In addition, we have examined results from groups of buildings, classified according to ventilation and usage characteristics. So far, there is no apparent difference among building classes. The paper also discusses our proposal for phased radon surveys. We suggest that first-phase results can be used to identify facilities with radon problems. In the second phase, we suggest measurements be made at a much higher sampling density at facilities with radon problems. The results of the second phase are expected to identify all buildings in need of mitigation

  2. Sampling strategies for indoor radon investigations

    International Nuclear Information System (INIS)

    Prichard, H.M.

    1983-01-01

    Recent investigations prompted by concern about the environmental effects of residential energy conservation have produced many accounts of indoor radon concentrations far above background levels. In many instances time-normalized annual exposures exceeded the 4 WLM per year standard currently used for uranium mining. Further investigations of indoor radon exposures are necessary to judge the extent of the problem and to estimate the practicality of health effects studies. A number of trends can be discerned as more indoor surveys are reported. It is becoming increasingly clear that local geological factors play a major, if not dominant role in determining the distribution of indoor radon concentrations in a given area. Within a giving locale, indoor radon concentrations tend to be log-normally distributed, and sample means differ markedly from one region to another. The appreciation of geological factors and the general log-normality of radon distributions will improve the accuracy of population dose estimates and facilitate the design of preliminary health effects studies. The relative merits of grab samples, short and long term integrated samples, and more complicated dose assessment strategies are discussed in the context of several types of epidemiological investigations. A new passive radon sampler with a 24 hour integration time is described and evaluated as a tool for pilot investigations

  3. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    International Nuclear Information System (INIS)

    George, A.C.; Knutson, E.O.; Tu, K.W.; Fisenne, I.M.

    1995-12-01

    The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC). There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is -3

  4. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus...... of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested....

  5. Establishment of a radon test chamber

    International Nuclear Information System (INIS)

    Chen Chingjiang; Liu Chichang; Lin Yuming

    1993-01-01

    A walk-in type radon test chamber of 23 m 3 has been built for testing and calibration of radon measurement instruments. The environmental conditions of the test chamber can be varied within a wide range of values. The design objectives specification, monitoring instruments and testing results of this chamber are discussed. This test chamber is available for domestic radon researchers and its accuracy can be traced to the international standard. A routine intercomparison study will be held annually by using this chamber. Other tests like radon progeny and thoron standard may also be performed in this chamber. (1 fig.)

  6. Comparison of radon and radon-daughter grab samples obtained during the winter and summer

    International Nuclear Information System (INIS)

    Karp, K.E.

    1987-08-01

    The Technical Measurements Center (TMC), under the auspices of the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) program, is investigating short-term methods for estimating annual average indoor radon-daughter concentrations (RDC). A field study at 40 sample locations in 26 residential structures in Grand Junction, Colorado, was conducted once in the winter and once in the summer. The short-term methods investigated as part of this study include ten-minute radon and radon-daughter grab sampling and hourly RDC measurements. The results of the field study indicate that ten-minute radon grab samples from basement locations are reproducible over different seasons during controlled sampling conditions. Nonbasement radon and RDC grab samples are highly variable even when the use of the location by the occupant is controlled and the ventilation rate is restricted. The grab sampling was performed under controlled occupied conditions. These results confirm that a short-term radon or RDC measurement in a nonbasement location in a house is not a standardized measurement that can be used to infer an annual average concentration. The hourly RDC measurements were performed under three sets of conditions over a 72-hour period. The three sets of conditions were uncontrolled occupied, controlled occupied, and controlled unoccupied. These results indicate that it is not necessary to relocate the occupants during the time of grab sampling. 8 refs., 8 figs., 10 tabs

  7. Air pollution. Actions to promote radon testing

    International Nuclear Information System (INIS)

    Guerrero, Peter F.; Adams, Charles M.; McGee, William F.; Goldsmith, Larry A.; Feldesman, Alice G.; Grissinger, Charles R.; Updegraff, William D.; Langdon, Robin S.; Bartholomew, Philip L.

    1992-12-01

    To promote radon testing, EPA initiated public information and awareness programs and provided grants to states to develop programs aimed at encouraging homeowners to test for radon. Nationwide telephone surveys, according to EPA, indicate that these efforts have raised the public awareness of radon to as high as 78 percent but that about only 9 percent of those surveyed have tested their homes for radon. Concerned about improving risk reduction through its radon program, EPA convened a review panel. The panel not only recommended in May 1992 that the current voluntary approach be continued but also called for program changes to encourage more testing. These changes include targeting public information and other resources to areas where radon levels are predicted to be high and promoting testing and mitigation at the time of real estate transactions. To support state radon efforts, the Congress authorized a grant program for yearly grants of $10 million for 3 years. Funds for this program were recently extended for a fourth year through fiscal year 1993. Information to measure states' success in promoting testing by homeowners was generally not available because (1) much of the grant funding has been used to identify the extent of the radon problem; (2) federally funded public information projects were often directed to large audiences, making it difficult to measure testing rates; and (3) EPA's evaluation process for the grant program did not contain a component to measure increases in testing. We did, however, identify some state projects that have increased radon testing by targeting program efforts to homes in areas with potentially high levels of radon. The results of the state projects would seem to support the EPA review panel's recommendations on promoting radon testing through targeting program resources. In two states we surveyed, the voluntary use of disclosure statements as part of a real estate sales contract was a frequent occurrence, and in one state

  8. Radon measurement in Malaysia water samples

    International Nuclear Information System (INIS)

    Ibrahim, A.B.; Rosli Mahat; Yusof Md Amin

    1995-01-01

    This paper reported the results of the measurement of radon in local water. The water samples collected were rainwater, river water, seawater, well water or ground water at area of State of Selangor and Kuala Lumpur. The samples were collected in scintillation cell ZnS(Ag) through Radon Degassing Unit RDU 200. Alpha activity was counted with scintillation counters RD 200 at energy 5.5 MeV. (author)

  9. Radon and radon daughter measurements at and near the former Middlesex Sampling Plant, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    Haywood, F.F.; Perdue, P.T.; Christian, D.J.; Leggett, R.W.; Dickson, H.W.; Myrick, T.E.

    1980-03-01

    The results of the radon and radon daughter measurements made to date (1978) at the Middlesex Sampling Plant in Middlesex, New Jersey, are presented in this report. These measurements were one portion of a more comprehensive radiological survey conducted at this site and the surrounding area from 1976 to 1978. The surveyed property served as a uranium ore sampling plant during the 1940's and early 1950's and as a result contains elevated levels of surface an subsurface contamination. On-site indoor radon daughter and radon concentrations exceeded both the US Surgeon General Guidelines and the Nuclear Regulatory Commission's maximum permissible concentration limits for radon (10 CFR Part 20) in all structures surveyed. Off-site structures showed concentrations of radon and radon daughters at or only slightly above background levels, except for one site where the radon levels were found to be above the 10 CFR Part 20 guidelines. Outdoor radon ad radon daughter concentrations, measured both on and off the site, were well below the guidelines, and the data give no indication of significant radon transport from the site

  10. Procedure manual for the estimation of average indoor radon-daughter concentrations using the radon grab-sampling method

    International Nuclear Information System (INIS)

    George, J.L.

    1986-04-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center to provide standardization, calibration, comparability, verification of data, quality assurance, and cost-effectiveness for the measurement requirements of DOE remedial action programs. One of the remedial-action measurement needs is the estimation of average indoor radon-daughter concentration. One method for accomplishing such estimations in support of DOE remedial action programs is the radon grab-sampling method. This manual describes procedures for radon grab sampling, with the application specifically directed to the estimation of average indoor radon-daughter concentration (RDC) in highly ventilated structures. This particular application of the measurement method is for cases where RDC estimates derived from long-term integrated measurements under occupied conditions are below the standard and where the structure being evaluated is considered to be highly ventilated. The radon grab-sampling method requires that sampling be conducted under standard maximized conditions. Briefly, the procedure for radon grab sampling involves the following steps: selection of sampling and counting equipment; sample acquisition and processing, including data reduction; calibration of equipment, including provisions to correct for pressure effects when sampling at various elevations; and incorporation of quality-control and assurance measures. This manual describes each of the above steps in detail and presents an example of a step-by-step radon grab-sampling procedure using a scintillation cell

  11. Comparison of a continuous working level monitor for radon daughters with conventional grab-sampling

    International Nuclear Information System (INIS)

    Bigu, J.; Grenier, M.

    1982-08-01

    An evaluation of a radon daughter monitor was carried out under laboratory controlled conditions. The monitor operates on continuous sampling and time integrating principles and was tested in conjunction with a newly designed, large radon/thoron room calibration facility. The monitor was tested under constant and rapidly fluctuating radiation conditions. Experimental data obtained with the monitor were compared with data obtained by conventional grab-sampling and with an automated radon daughter/thoron daughter 'grab-sampler'. The Working Level used in the tests ranged from less than 0.01 WL to approximately 10 WL. The measurements were carried out under low aerosol concentration (1 x 10 3 - 2 x 10 3 cm -3 , approximately) to study plate-out effects in the sampling head. Good agreement (within about 10 %) was found between the monitor, conventional grab-sampling and the automated grab-sampler. The monitor should prove quite flexible, useful and reliable for monitoring underground and surface environments in the uranium mining industry

  12. γ-Ray spectrometry of radon in water and the role of radon to representatively sample aquifers

    International Nuclear Information System (INIS)

    Talha, S.A.; Lindsay, R.; Newman, R.T.; Meijer, R.J. de; Maleka, P.P.; Hlatshwayo, I.N.; Mlwilo, N.A.; Mohanty, A.K.

    2008-01-01

    Measurement of radon in water by γ-ray spectrometry using a HPGe detector has been investigated to determine aquifer characteristics. The radon activity concentration is determined by taking the weighted average of the concentrations derived from γ-ray lines associated with 214 Pb and 214 Bi decay. The role of accurate radon data to representatively sample aquifers was also investigated by studying a semi-cased borehole. A simplified physical model describing the change of radon concentration with the pumping time, reproduces the data and predicts the time for representative sampling of the aquifer

  13. Real estate transaction radon test tampering

    International Nuclear Information System (INIS)

    Ritter, D.L.

    1990-01-01

    A thousand-house study, over the past two years showed 35% of the houses were tampered with. This paper offers statistical charts representing the different methods of tampering; A slide presentation showing houses and the non-tamper controls used to monitor EPA closed-house conditions, movement of detectors and covering of detectors. A strong message must be conveyed now, that tampering will not be tolerated by radon technicians, when performing radon tests in the field. A message that incorporates non-tamper controls that are cost effective and provide for reasonably priced testing; A message that will lend credibility to our Radon industry by means of separating the professional test from a do-it-yourself homeowner test. This paper will address that message and offer a program for the prevention of tampering in a house during a PROFESSIONALLY done Radon test

  14. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample.

    Science.gov (United States)

    Lee, Kil Yong; Burnett, William C

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 °C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods.

  15. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample

    International Nuclear Information System (INIS)

    Kil Yong Lee; Burnett, W.C.

    2013-01-01

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 deg C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods. (author)

  16. Radon risk perception and testing: Sociodemographic correlates

    International Nuclear Information System (INIS)

    Halpern, M.T.; Warner, K.E.

    1994-01-01

    While numerous health education campaigns have been carried out to alert the public to radon's potential dangers and to encourage testing and mitigation, there has been little follow-up to determine which segments of the public are now most aware of the possible hazards of radon. Using information from the 1990 National Health Interview Survey (NHIS), the authors have examined beliefs regarding radon and radon-testing activities among different sociodemographic groups. They used logistic regression to determine the relationship between these beliefs and actions and age, gender, education, income, minority status, and smoking status. The results suggest relatively superficial knowledge regarding radon, and very little testing, within the survey population. In particular, significantly less knowledge was observed among female and minority respondents, while less testing behavior was seen among older respondents. Lower educational levels and lower family income were associated with both decreased knowledge and testing. Recommendations for future education campaigns are discussed

  17. Variations in radon-222 in soil and ground water at the Nevada Test Site

    International Nuclear Information System (INIS)

    Wollenberg, H.; Straume, T.; Smith, A.; King, C.Y.

    1977-01-01

    To help evaluate the applicability of variations of radon-222 in ground water and soil gas as a possible earthquake predictor, measurements were conducted in conjunction with underground explosions at the Nevada Test Site (NTS). Radon fluctuations in ground water have been observed during a sequence of aftershocks following the Oroville, California earthquake of 1 August 1975. The NTS measurements were designed to show if these fluctuations were in response to ground shaking; if not, they could be attributed to changes in earth strain prior to the aftershocks. Well waters were periodically sampled and soil-gas 222 Rn monitored prior to and following seven underground explosions of varying strength and distance from sampling and detector locations. Soil-gas 222 Rn contents were measured by the alpha-track method; well water 222 Rn by gamma-ray spectrometry. There was no clearly identifiable correlation between well-water radon fluctuations and individual underground tests. One prominent variation in soil-gas radon corresponded to ground shaking from a pair of underground tests in alluvium; otherwise, there was no apparent correlation between radon emanation and other explosions. Markedly lower soil-gas radon contents following the tests were probably caused by consolidation of alluvium in response to ground shaking

  18. Radon in homes of the Portland, Oregon Area: Radon data from local radon testing companies collected by CRM (Continuous Radon Measurement) machines

    Science.gov (United States)

    Whitney, H.; Lindsey, K.; Linde, T.; Burns, S. F.

    2013-12-01

    Students from the Department of Geology at Portland State University paired up with the Oregon Health Authority to better understand radon gas values in homes of the Portland metropolitan area. This study focuses on radon values collected by continuous radon measurement (CRM) machines, taken by local radon testing companies. The local companies participating in this study include Alpha Environmental Services, Inc., Cascade Radon, Environmental Works, The House Detectives, LLC, and Soil Solutions Environmental Services, Inc. In total, 2491 radon readings spanning across 77 zip codes were collected from local companies in the Portland metropolitan area. The maximum value, average value, percentage of homes greater than 4 pCi/L and total rank sum was calculated and used to determine the overall radon potential for each zip code (Burns et al., 1998). A list and four maps were produced showing the results from each category. Out of the total records, 24 zip codes resulted in high radon potential and the average reading for the entire Portland Metropolitan area was 3.7 pCi/L. High potential zip codes are thought to be a result of sand and gravel (Missoula Flood deposits) and faults present in the subsurface. The CRM data was compared with both long-term and short-term data provided by the Oregon Health Authority to validate radon potentials in each zip code. If a home is located in a zip code with high or moderate radon potential across two types of data sets, it is recommended that those homes be tested for radon gas.

  19. An investigation into the knowledge and attitudes towards radon testing among residents in a high radon area

    International Nuclear Information System (INIS)

    Clifford, Susan; Menezes, Gerard; Hevey, David

    2012-01-01

    The aim of this study was to investigate the knowledge and attitudes of residents in the Castleisland area to radon. Castleisland in Co. Kerry was described as a high radon area following the discovery of a house in the area with radon levels 245 times that of the national reference level. Residents in this area were then asked to measure their homes for radon in the Castleisland radon survey. The uptake of this measurement was 17%. In order to investigate this response rate further, a questionnaire was designed and distributed to residents in the Castleisland area. This questionnaire measured the testing history of the participants, the reasons for testing/not testing, the factors important to them when considering having their home tested, radon knowledge and finally intentions to measure their home for radon. It was found that the main reason people do not test their home for radon is that they believe their home does not have a problem. Optimistic bias was thought to play a role here. The subjective norm component of the theory of planned behaviour was found to have a significant independent contribution in the variation in intentions to measure one’s home for radon and this in turn could be targeted to increase uptake of radon measurement in the future. (note)

  20. Radon exhalation from samples of Danish soils, subsoils and sedimentary rocks

    International Nuclear Information System (INIS)

    Korsbech, U.

    1985-01-01

    For some years it has been known that the ground below a house could be the major source of radon and radon daughters in the indoor air. Th amount of radon penetrating into buildings from the ground depends on several factors e.g. the amount of radon produced in the ground, the amount of cracks and holes in the foundation of buildings, and the pressure difference between the air in the ground (sol air) and the indoor air. As a first step in determining the influence of the ground below Danish buildings 60 samples of soils, subsoils, and sedimentary rocks have been measured for their exhalation rates of radon i.e. the amount of radon escaping the sample per mass unit and per second (Bq.kg -1 .s -1 or radon atoms per kg and per sec.). The results of the measurements of the radon exhalation are presented and commented, and a conclusion concerning the methods for finding geological deposits with a high radon halation rate is presented. (author)

  1. Residents in a high radon potential geographic area: Their risk perception and attitude toward testing and mitigation

    International Nuclear Information System (INIS)

    Ferng, S.F.; Lawson, J.K.

    1996-01-01

    Boone County, Indiana was identified by the EPA as one of the high radon potential geographic areas. Health education campaigns are needed to prevent resident's unnecessary radon exposure. In order to design suitable programs, a questionnaire mail survey was conducted to measure socio-demographic characteristics of County resident's knowledge about radon, attitude toward radon testing and mitigation, support of education campaigns, and the best media to deliver radon education campaigns. A stratified random sampling method was applied for a total of 400 samples. The number of samples from each township/city was a proportion of their taxable parcels. The survey return rate was 39.8%. The data were analyzed by Epi Info and SPSS. The statistical significant level was set at α = 0.05. The results showed that resident's knowledge about radon was at a relatively superficial level. There was no association identified between the knowledge of radon and gender, age, family income, or education, except that females more frequently believed in false effects caused by radon. A significant correlation between radon knowledge and home radon tests was observed. Also found in this study was that respondents with better knowledge about diseases caused by radon had more confidence in radon mitigation actions. Newspaper was chosen by respondents as the most favorite media to deliver radon health education campaigns. Health education campaigns for the residents of Boone County might be conducted by local governments and/or other organizations

  2. Radon in large buildings

    International Nuclear Information System (INIS)

    Wilson, D.L.; Dudney, C.S.; Gammage, R.B.

    1993-01-01

    Over the past several years, considerable research has been devoted by the U.S. Environmental Protection Agency (USEPA) and others to develop radon sampling protocols for single family residences and schools. However, very little research has been performed on measuring radon in the work place. To evaluate possible sampling protocols, 833 buildings throughout the United States were selected for extensive radon testing. The buildings tested (warehouses, production plants and office buildings) were representative of commercial buildings across the country both in design, size and use. Based on the results, preliminary radon sampling protocols for the work place have been developed. (orig.). (5 refs., 3 figs.)

  3. Radon exhalation rates from slate stone samples in Aravali Range in Haryana

    International Nuclear Information System (INIS)

    Upadhyay, S.B.; Kant, K.; Chakarvarti, S.K.

    2012-01-01

    The slate stone tiles are very popular in covering the walls of the rooms. Radon is released into ambient air from slate stones due to ubiquitous uranium and radium in them, thus increasing the airborne radon concentration. The radioactivity in slates stones is related to radioactivity in the rocks from which the slate stone tiles are formed. In the present investigation, the radon emanated from slate stone samples collected from different slate mines in Aravali range of hills in the Haryana state of Northern India has been estimated. For the measurement of radon concentration emanated from these samples, alpha-sensitive LR-115 type II plastic track detectors have been used. The alpha particles emitted from the radon form tracks in these detectors. After chemical etching the track density of registered tracks is used to calculate radon concentration and exhalation rates of radon using required formulae. The measurements indicate normal to some higher levels of radon concentration emanated from the slat stone samples collected from Aravali range of hills in north India. The results will be discussed in full paper. (author)

  4. Communicating radon risk effectively: Radon testing in Maryland. Final report

    International Nuclear Information System (INIS)

    Desvousges, W.H.; Smith, V.K.; Rink, H.H.

    1988-10-01

    Two sets of materials and corresponding delivery strategies for communicating radon risk were evaluated, compared with a 'no-special-treatment' strategy in a comparison community. One community received radio public-service announcements and utility bill inserts. The second received these plus posters, local government sponsorship of a radon awareness week, and local slide presentations. The most-intensive efforts (multiple channels, multiple hits) were more effective than the less intensive effort, which had little impact compared with no special treatment. From a marketing perspective, the effort was very successful, increasing the share of homeowners who tested for radon from 5% to 15%. This may not be viewed as sufficiently effective from a public-health perspective, however

  5. Field testing of asphalt-emulsion radon-barrier system

    International Nuclear Information System (INIS)

    Hartley, J.N.; Freeman, H.D.; Baker, E.G.; Elmore, M.R.; Nelson, D.A.; Voss, C.F.; Koehmstedt, P.L.

    1981-09-01

    Three years of laboratory and field testing have demonstrated that asphalt emulsion seals are effective radon diffusion barriers. Both laboratory and field tests in 1979, 1980 and 1981 have shown that an asphalt emulsion seal can reduce radon fluxes by greater than 99.9%. The effective diffusion coefficient for the various asphalt emulsion admix seals averages about 10 -6 cm 2 /s. The 1981 joint field test is a culmination of all the technology developed to date for asphalt emulsion radon barrier systems. Preliminary results of this field test and the results of the 1980 field test are presented. 18 figures, 6 tables

  6. Validation of the abbreviated Radon Progeny Integrating Sampling Unit (RPISU) method for Mesa County, Colorado

    International Nuclear Information System (INIS)

    Langner, G.H. Jr.

    1987-06-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center at the DOE Grand Junction, Colorado, Projects Office to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Indoor radon-daughter concentration measurements are made to determine whether a structure is in need of remedial action. The Technical Measurements Center conducted this study to validate an abbreviated Radon Progeny Integrated Sampling Unit (RPISU) method of making indoor radon-daughter measurements to determine whether a structure has a radon-daughter concentration (RDC) below the levels specified in various program standards. The Technical Measurements Center established a criterion against which RDC measurements made using the RPISU sampling method are evaluated to determine if sampling can be terminated or whether further measurements are required. This abbreviated RPISU criterion was tested against 317 actual sets of RPISU data from measurements made over an eight-year period in Mesa County, Colorado. The data from each location were tested against a standard that was assumed to be the same as the actual annual average RDC from that location. At only two locations was the criterion found to fail. Using the abbreviated RPISU method, only 0.6% of locations sampled can be expected to be falsely indicated as having annual average RDC levels below a given standard

  7. Radon discrimination for work place air samples

    International Nuclear Information System (INIS)

    Bratvold, T.

    1994-01-01

    Gross alpha/beta measurement systems are designed solely to identify an incident particle as either an alpha or a beta and register a count accordingly. The tool of choice for radon identification, via decay daughters, is an instrument capable of identifying the energy of incident alpha particles and storing that information separately from detected alpha emissions of different energy. In simpler terms, the desired instrument is an alpha spectroscopy system. K Basins Radiological Control (KBRC) procured an EG ampersand G ORTEC OCTETE PC alpha spectroscopy system to facilitate radon identification on work place air samples. The alpha spectrometer allows for the identification of any alpha emitting isotope based on characteristic alpha emission energies. With this new capability, KBRC will explicitly know whether or not there exists a true airborne concern. Based on historical air quality data, this new information venue will reduce the use of respirators substantially. Situations where an area remains ''on mask'' due solely to the presence of radon daughters on the grab air filter will finally be eliminated. This document serves to introduce a new method for radon daughter detection at the 183KE Health Physics Analytical Laboratory (HPAL). A new work place air sampling analysis program will be described throughout this paper. There is no new technology being introduced, nor any unproven analytical process. The program defined over the expanse of this document simply explains how K Basins Radiological Control will employ their alpha spectrometer

  8. The feasible research with measuring radon for taking the soils sample

    International Nuclear Information System (INIS)

    Zeng Bing, Ge Liangquan; Liu Hefan; Li Yeqiang; Zhang Jinzhao; Song Xiao'an

    2010-01-01

    It explains the mechanism of the separation of soil's radon. Through the designed experiment, it confirms the feasibility of measuring radon for taking the soil's sample. It determines the content of the radon and its sub field with indoor and outside through ways of the activated charcoal adsorption, the initiative suction and the diameter mark etching, also the 226 Ra. The paper indicates: it is feasible with measuring radon for taking the soil's sample, and the stability of data is that indoor data are better than outside's. The temperature, the humidity, the rainfall amount, the intensity and so on are the serious influence of the data. If you want to take a soil's sample, you must avoid the rain as far as possible, and avoid the fault zone, the belt of folded strata and complex geologic structure region, and so on. (authors)

  9. Radon induced radiological impact of coal, fly ash and cement samples

    International Nuclear Information System (INIS)

    Kant, K.; Chauhan, R.P.; Sharma, G.S.; Chakravarti, S.K.

    2001-01-01

    Coal and its by-product fly ash are technologically important materials being used for power generation and in the manufacture of bricks, sheets, cement, land-filling, etc., respectively. Increased interest in measuring radon concentration in coal, fly ash and cement is due to its health hazards and environmental pollution. As the presence of radon in the environment (indoor and outdoor), soil, ground water, oil and gas deposits contributes the largest fraction of the natural radiation dose to populations, tracking its concentration is thus of paramount importance for radiological protection. Samples of coal and fly ash were collected from different thermal power stations in northern India and cement samples from National Council for Cement and Building Materials, Ballabgarh (Haryana), India and were analysed for radon concentration. For the measurement, alpha sensitive LR-115 type II plastic track detectors were used. Based upon the available data, the annual effective dose and the lifetime fatality risk factors have been calculated. The radon concentration from coal samples varied from 433 ± 28 Bqm -3 to 2086 ± 28 Bqm -3 . The radon concentration from fly ash samples varied from 748 ± 28 Bqm -3 to 1417 ± 111 Bqm -3 and from 158 Bqm -3 to 1810 Bqm -3 in cement samples, with an average of 624 ± 169 Bqm -3 . (author)

  10. Estimation of radon concentration in soil and groundwater samples of Northern Rajasthan, India

    International Nuclear Information System (INIS)

    Mittal, Sudhir; Asha Rani; Mehra, Rohit

    2015-01-01

    In the present investigation, analysis of radon concentration in 20 water and soil samples collected from different locations of Bikaner and Jhunjhunu districts of Rajasthan, India has been carried out by using RAD7 an electronic Radon detector. The water samples are taken from hand pumps and tube wells having depths ranging from 50 to 600 feet. All the soil gas measurements have been carried out at 100 cm depth. The measured radon concentration in water samples lies in the range from 0.50 to 22 Bq l -1 with the mean value of 4.42 Bq l -1 . Only in one water sample radon concentration is found to be higher than the safe limit of 11 Bq l -1 recommended US Environmental Protection Agency (USEPA, 1991). The measured value of radon concentration in all ground water samples is within the safe limit from 4 to 40 Bq l -1 recommended by United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR, 2008). The total annual effective dose estimated due to radon concentration in water ranges from 1.37 to 60 μSV y -1 with the mean value of 12.08 μSV y -1 . The total annual effective dose from all locations of our studied area is found to be well within the safe limit 0.1 mSv y -1 recommended by World Health Organization (WHO, 2004) and European Council (ED, 1998). Radon measurement in soil samples varies from 941 to 10050 Bq m -3 with the mean value of 4561 Bq m -3 , The radon concentration observed from the soil samples from our study area lies within the range reported by other investigators. Moreover a positive correlation of radon concentration in water with soil samples has been observed. It was observed that the soil and water of Bikaner and Jhunjhunu districts are suitable for drinking and construction purpose without posing any health hazard. (author)

  11. One cubic metre NIST traceable radon test chamber

    International Nuclear Information System (INIS)

    Kotrappa, P.; Stieff, F.

    2008-01-01

    With the availability of the National Inst. of Standards and Technology (NIST) Radon Emanation Standard with a content of ∼5000 Bq of 226 Ra, it is possible to build a flow through a practical radon test chamber. A standard glove box with four gloves and a transfer port is used. Air is pumped through a flow integrator, water jar for humidification and NIST source holder, and into the glove box through a manifold. A derived theoretical expression provides the calculated radon concentration inside the chamber. The calculation includes a derived decay correction due to the large volume and low flow rate of the system. Several calibrated continuous radon monitors and passive integrating electret ion chambers tested in the chamber agreed fairly well with the calculated radon concentrations. The chamber is suitable for handling the calibration of several detectors at the same time. (authors)

  12. Study of radon exhalation and emanation rates from fly ash samples

    International Nuclear Information System (INIS)

    Raj Kumari; Jain, Ravinder; Kant, Krishan; Gupta, Nitin; Garg, Maneesha; Yadav, Mani Kant

    2013-01-01

    Fly ash, a by-product of burnt coal is technologically important material being used for manufacturing of bricks, sheets, cement, land filling etc. The increased interest in measuring radon exhalation and emanation rates in fly ash samples is due to its health hazards and environmental pollution and the same have been measured to assess the radiological impact of radon emanated from fly ash disposal sites. Samples of fly ash from different thermal power stations in northern India and National Council for Cement and Building Materials (NCB) were collected and analysed for the measurements. For the measurement, alpha sensitive LR-115 type II plastic track detectors were used. Gamma spectrometry and can technique was used for the measurements. The experimental data show that fly ash samples emanate radon in significant amount and this consequently, may result in increased radon levels in dwellings built by using fly ash bricks and excessive radiation exposure to workers residing in the surroundings of fly ash dumping sites. (author)

  13. Airborne radon-222 measurement by active sampling with charcoal adsorption and gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Shizuma, Kiyoshi; Wen, Xiao-qiong; Fukami, Kenji; Iwatani, Kazuo; Hamanaka, Shun-ichi

    1998-01-01

    A simple method for measuring radon concentration in air is presented. Airborne radon is adsorbed in a charcoal bed by an active air sampling. In time, the adsorbed radon comes to attain radioactive equilibrium with its short-lived progeny 214 Pb. Utilizing this fact, radon concentration is derived from γ-ray measurement of 214 Pb. This method is estimated to be capable of detecting radon concentration in air down to 0.79 Bq·m -3 . The adsorption coefficient obtained with the method is compared with what is obtainable with passive sampling. Applications of this method to indoor and outdoor radon measurements are described. (author)

  14. Pumping time required to obtain tube well water samples with aquifer characteristic radon concentrations

    International Nuclear Information System (INIS)

    Ricardo, Carla Pereira; Oliveira, Arno Heeren de

    2011-01-01

    Radon is an inert noble gas, which comes from the natural radioactive decay of uranium and thorium in soil, rock and water. Radon isotopes emanated from radium-bearing grains of a rock or soil are released into the pore space. Radon that reaches the pore space is partitioned between the gaseous and aqueous phases. Thus, the groundwater presents a radon signature from the rock that is characteristic of the aquifer. The characteristic radon concentration of an aquifer, which is mainly related to the emanation, is also influenced by the degree of subsurface degassing, especially in the vicinity of a tube well, where the radon concentration is strongly reduced. Looking for the required pumping time to take a tube well water sample that presents the characteristic radon concentration of the aquifer, an experiment was conducted in an 80 m deep tube well. In this experiment, after twenty-four hours without extraction, water samples were collected periodically, about ten minutes intervals, during two hours of pumping time. The radon concentrations of the samples were determined by using the RAD7 Electronic Radon Detector from Durridge Company, a solid state alpha spectrometric detector. It was realized that the necessary time to reach the maximum radon concentration, that means the characteristic radon concentration of the aquifer, is about sixty minutes. (author)

  15. Environmental site assessments should include radon gas testing

    International Nuclear Information System (INIS)

    Nardi, M.A.

    1991-01-01

    There are two emerging influences that will require radon gas testing as part of many property transfers and most site assessments. These requirements come from lending regulators and state legislatures. Fannie Mae and others have developed environmental investigation guidelines for the purchase of environmentally contaminated real estate. These guidelines include radon gas testing for many properties. Several states have enacted laws that require environmental disclosure forms be prepared to ensure that the parties involved in certain real estate transactions are aware of the environmental liabilities that may come with the transfer of property. Indiana has recently enacted legislation that would require the disclosure of the presence of radon gas on many commercial real estate transactions. With more lenders and state governments likely to follow this trend, radon gas testing should be performed during all property transfers and site assessment to protect the parties involved from any legal liabilities

  16. A summary of EPA radon chamber tests and results for rounds 3 and 4 of the National Radon Measurement Proficiency Program

    International Nuclear Information System (INIS)

    Smith, J.M.; Sensintaffar, E.L.

    1993-02-01

    The US Environmental Protection Agency's Office of Radiation and Indoor Air (ORIA) established the National Radon Measurement Proficiency (RMP) Program in 1986. Through this voluntary program, participants can demonstrate their ability to measure radon and/or radon decay products by submitting their detection devices to a blind test in a designated radon chamber. In this report, two EPA radon and radon decay products test chambers (chambers A and C) located at the National Air and Radiation Environmental Laboratory in Montgomery, Alabama are described. These chambers were used to expose detectors submitted for testing in Round 4 of the National Radon Measurement Proficiency Program and are used routinely for calibration purposes. Also described are the measurement and calibration procedures which were used to establish the official target values for radon and radon decay products concentrations during RMP Round 4 testing. The results for RMP Round 3 (conducted at the US DOE Environmental Measurements Laboratory radon chamber in New York) and RMP Round 4 (conducted in the two NAREL chambers) are discussed and compared. Following Round 4, the NAREL staff analyzed the collective performance for each measurement method tested in these rounds and found that all methods agreed with the target values within expected limits except for RPISU's and charcoal adsorbers. After analyzing the RMP4 results, NAREL staff spent several months evaluating the difference in charcoal adsorber response between Round 3 and 4 by performing radon chamber tests using EPA 4-inch, open-faced charcoal adsorbers

  17. Property transfer assessments should include radon gas testing

    International Nuclear Information System (INIS)

    Nardi, M.A.

    1992-01-01

    There are two emerging influences that will require radon gas testing as part of many property transfers and most environmental assessments. These requirements come from lending regulators and state legislatures and affect single family, multifamily, and commercial properties. Fannie Mae and others have developed environmental investigation guidelines for protection from long term legal liabilities in the purchase of environmentally contaminated real estate. These guidelines include radon gas testing for many properties. Several states have enacted laws that require environmental disclosure forms be prepared to ensure that the parties involved in certain real estate transactions are aware of the environmental liabilities that may come with the transfer of property. Indiana has recently enacted legislation that would require the disclosure of the presence of radon gas on many commercial real estate transactions. With more banks and state governments following this trend, radon gas testing should be performed during all property transfers and environmental assessments to protect the parties involved from any long term legal liabilities

  18. Radium and radon exhalation rate in soil samples of Hassan district of South Karnataka, India

    International Nuclear Information System (INIS)

    Jagadeesha, B.G.; Narayana, Y.

    2016-01-01

    The radon exhalation rate was measured in 32 soil samples collected from Hassan district of South Karnataka. Radon exhalation rate of soil samples was measured using can technique. The results show variation of radon exhalation rate with radium content of the soil samples. A strong correlation was observed between effective radium content and radon exhalation rate. In the present work, an attempt was made to assess the levels of radon in the environment of Hassan. Radon activities were found to vary from 2.25±0.55 to 270.85±19.16 Bq m"-"3 and effective radium contents vary from 12.06±2.98 to 1449.56±102.58 mBq kg"-"1. Surface exhalation rates of radon vary from 1.55±0.47 to 186.43±18.57 mBq m"-"2 h"-"1, and mass exhalation rates of radon vary from 0.312±0.07 to 37.46±2.65 mBq kg"-"1 h"-"1. (authors)

  19. Assessment of radon and thoron exhalation from Indian cement samples using smart radon and thoron monitors

    International Nuclear Information System (INIS)

    Sahoo, B.K.; Sapra, B.K; Agarwal, T.K.; Babu, D.A.R.

    2015-01-01

    It has been established that primarily, there exist two important sources that contribute to indoor radon/thoron namely, the exhalation from ground and building materials. The contribution from ground, although significant, is treated as a case of existing exposure. Then, the only source that can be controlled during the construction is the choice of building materials. Cement is an important building material used in the construction of houses and buildings in India. The housing sector is the largest cement consumer with 53% of the total Indian cement demand followed by the infrastructure sector. India with a production capacity of 165 million tones (MT) (in 2007), was the second largest cement producer in the world after China. The industry produces various types of cement like ordinary portland cement (OPC), Portland pozzolana cement (PPC), portland slag cement (PSC), rapid hardening portland cement (RHPC), sulphate resistant cement (SRC) and white cement (WC). Several studies have been undertaken on cement in various countries because it is commonly used in bulk quantities in the construction of houses and other civil structures. However, detailed information regarding the radon and thoron exhalation into indoor air from various types of cements produced in India is scarce. In the present work, an attempt has been made to systematically determine the radon and thoron exhalation from 50 cement samples (17 OPC, 15 PPC, 04 PSC, 06 RHPC, 04 WC and 04 SRC). The data thus obtained is used to calculate the indoor radon and thoron source term and the contributed inhalation dose based on a model room structure. The measured values of radon and thoron exhalation from cement samples were comparable with the reported values in other countries. This study showed that the cement samples used in civil constructions do not pose any radiological hazard to the Indian population. (author)

  20. Sampling and analysis for radon-222 dissolved in ground water and surface water

    Science.gov (United States)

    DeWayne, Cecil L.; Gesell, T.F.

    1992-01-01

    Radon-222 is a naturally occurring radioactive gas in the uranium-238 decay series that has traditionally been called, simply, radon. The lung cancer risks associated with the inhalation of radon decay products have been well documented by epidemiological studies on populations of uranium miners. The realization that radon is a public health hazard has raised the need for sampling and analytical guidelines for field personnel. Several sampling and analytical methods are being used to document radon concentrations in ground water and surface water worldwide but no convenient, single set of guidelines is available. Three different sampling and analytical methods - bubbler, liquid scintillation, and field screening - are discussed in this paper. The bubbler and liquid scintillation methods have high accuracy and precision, and small analytical method detection limits of 0.2 and 10 pCi/l (picocuries per liter), respectively. The field screening method generally is used as a qualitative reconnaissance tool.

  1. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    International Nuclear Information System (INIS)

    Hayes, Robert

    2009-01-01

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level

  2. Radon mass exhalation rate in soil samples at South Bengaluru city, Karnataka, India

    International Nuclear Information System (INIS)

    Poojitha, C.G.; Pranesha, T.S.; Ganesh, K.E.; Sahoo, B.K.; Sapra, B.K.

    2017-01-01

    Radon mass exhalation rate in soil samples collected from different locations of South Bengaluru city were measured using scintillation based Smart radon thoron monitor (RnDuo). It has been observed that the mass exhalation rate estimated due to presence of radon concentration in soil samples ranges from 39.18 - 265.58 mBq/kg/h with an average value of 115.64 mBq/kg/h. Finally we compare our results with similar investigation from different parts of India. (author)

  3. Radon exhalation rates from soil and sand samples collected from the vicinity of Yamuna river

    International Nuclear Information System (INIS)

    Garg, A.K.; Sushil Kumar; Chauhan, Pooja; Chauhan, R.P.

    2011-01-01

    Soil, sand and stones are the most popular building materials for Indian dwellings. Radon is released into ambient air from these materials due to ubiquitous uranium and radium in them, thus increasing the airborne radon concentration. The radioactivity in sand and soils is related to radioactivity in the rocks from which they are formed. These materials contain varying amount of uranium. In the present investigation, the radon emanated from soil and sand samples from different locations in the vicinity of Yamuna river has been estimated. The samples have been collected from different locations near the Yamuna river. The samples collecting sites are from Yamunanagar in Haryana to Delhi. The radon concentration in different samples has been calculated, based upon the data, the mass and the surface exhalation rates of radon emanated from them have also been calculated

  4. Evaluation of the performance characteristics of radon and radon-daughter concentration measurement devices under controlled environmental conditions

    International Nuclear Information System (INIS)

    Pearson, M.D.

    1989-04-01

    The Technical Measurements Center (TMC) conducted a study to expose 10 radon and 7 radon-daughter concentration measurement devices in the DOE/GJPO Radon/Radon-Daughter Environmental Chamber for a series of 24 controlled-environment tests. The tests evaluated the devices' response to temperature, relative humidity, dew point, condensation-nuclei concentration, radon-daughter/radon equilibrium ratio, and non-uniform radon and radon-daughter concentration. Devices were evaluated for linear response as a function of concentration. In addition to response to environmental parameters, the evaluation included determining the utility of the devices in providing reasonable assurance of compliance with the radon and radon-daughter concentration standards for DOE remedial action programs. This reasonable assurance criterion is based on a coefficient of variation of 25 percent for devices deployed for year-long measurements and a coefficient of variation of 18 percent for devices deployed for intermittent sampling. 39 refs., 65 figs., 33 tabs

  5. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    International Nuclear Information System (INIS)

    Scarpitta, S.C.; Tu, K.W.; Fisenne, I.M.; Cavallo, A.; Perry, P.

    1996-10-01

    Results are presented from the Fifth Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurements conducted in the EML radon exposure and test facility in May 1996. In total, thirty-four government, private and academic facilities participated in the exercise with over 170 passive and electronic devices exposed in the EML test chamber. During the first week of the exercise, passive and continuous measuring devices were exposed (usually in quadruplicate) to about 1,280 Bq m -3 222 Rn for 1--7 days. Radon progeny measurements were made during the second week of the exercise. The results indicate that all of the tested devices that measure radon gas performed well and fulfill their intended purpose. The grand mean (GM) ratio of the participants' reported values to the EML values, for all four radon device categories, was 0.99 ± 0.08. Eighty-five percent of all the radon measuring devices that were exposed in the EML radon test chamber were within ±1 standard deviation (SD) of the EML reference values. For the most part, radon progeny measurements were also quite good as compared to the EML values. The GM ratio for the 10 continuous PAEC instruments was 0.90 ± 0.12 with 75% of the devices within 1 SD of the EML reference values. Most of the continuous and integrating electronic instruments used for measuring the PAEC underestimated the EML values by about 10--15% probably because the concentration of particles onto which the radon progeny were attached was low (1,200--3,800 particles cm -3 ). The equilibrium factor at that particle concentration level was 0.10--0.22

  6. Radon entry into a simple test structure

    DEFF Research Database (Denmark)

    Andersen, C.E.; Søgaard-Hansen, J.; Majborn, B.

    1992-01-01

    A simple test structure for studies of radon entry into houses has been constructed at a field site at Riso National Laboratory. It consists of a 40 1, stainless-steel cylinder placed in a 0.52 m deep quadratic excavation with a side length of 2.4 m. The excavation is lined with an airtight...... membrane, and soil gas enters the cylinder through a changeable interface in the bottom. The depressurisation of the cylinder is controlled by a mass-flow controller, thereby limiting the influence of natural driving forces. Pressures, temperatures and radon concentrations are measured continuously...... in the cylinder and in selected locations in the soil. In this paper, the test structure is described, and initial results concerning the transport of soil gas and radon under steady-state conditions are reported. It is found that the soil in the vicinity of the structure is partially depleted with respect...

  7. Measurement of radon-222 concentration in environment sampled within short time using charcoal detector

    International Nuclear Information System (INIS)

    Yamasaki, Tadashi; Sekiyama, Shigenobu; Tokin, Mina; Nakayasu, Yumiko; Watanabe, Tamaki.

    1994-01-01

    The concentration of 222 Rn in air sampled within a very short period of time was measured using activated charcoal as the adsorber. The detector is the plastic canister containing mixture of the activated charcoal and the silica gel. The radon gas was adsorbed in the charcoal in the radon chamber at the temperature of 25degC. A little amount of liquid scintillation cocktail was added into the vial of liquid scintillation counter with the canister. The radon in the charcoal was extracted in the liquid scintillation cocktail. Alpha particles emitted from radon and its daughter nuclei in the cocktail were detected using the liquid scintillation counter. Present method has advantages of not only short sampling time of air but also adsorption of radon in charcoal under a constant temperature. The concentration of radon in air down to 2 Bq/m 3 could be detected. A kinetic model for adsorption of radon in the charcoal is also presented. The ratio of radon concentration in the charcoal to that in air under the equilibrium state of adsorption was estimated to be from 6.1 to 6.8 m 3 /kg at the temperature of 25degC. (author)

  8. Measurement of radon exhalation rate in various building materials and soil samples

    Science.gov (United States)

    Bala, Pankaj; Kumar, Vinod; Mehra, Rohit

    2017-03-01

    Indoor radon is considered as one of the potential dangerous radioactive elements. Common building materials and soil are the major source of this radon gas in the indoor environment. In the present study, the measurement of radon exhalation rate in the soil and building material samples of Una and Hamirpur districts of Himachal Pradesh has been done with solid state alpha track detectors, LR-115 type-II plastic track detectors. The radon exhalation rate for the soil samples varies from 39.1 to 91.2 mBq kg-1 h-1 with a mean value 59.7 mBq kg-1 h-1. Also the radium concentration of the studied area is found and it varies from 30.6 to 51.9 Bq kg-1 with a mean value 41.6 Bq kg-1. The exhalation rate for the building material samples varies from 40.72 (sandstone) to 81.40 mBq kg-1 h-1 (granite) with a mean value of 59.94 mBq kg-1 h-1.

  9. 1981 radon barrier field test at Grand Junction uranium mill tailings pile

    International Nuclear Information System (INIS)

    Hartley, J.N.; Gee, G.W.; Baker, E.G.; Freeman, H.D.

    1983-04-01

    Technologies to reduce radon released from uranium mill tailings are being investigated by Pacific Northwest Laboratory as part of the Department of Energy's Uranium Mill Tailings Remedial Action Project (UMTRAP) Technology development program. These technologies include: (1) earthen cover systems, (2) multilayer cover systems, and (3) asphalt emulsion radon barrier systems. During the summer of 1981, a field test was initiated at the Grand Junction, Colorado, uranium tailings pile to evaluate and compare the effectiveness of each radon barrier system. Test plots cover about 1.2 ha (3 acres). The field test has demonstrated the effectiveness of all three cover systems in reducing radon release to near background levels ( 2 s - 1 ). In conjunction with the field tests, column tests (1.8 m diameter) were initiated with cover systems similar to those in the larger field test plots. The column tests allow a direct comparison of the two test procedures and also provide detailed information on radon transport

  10. Studies on radon concentration in underground water samples in and around Kabini river basin

    International Nuclear Information System (INIS)

    Yashaswini, T.; Ningappa, C.; Niranjan, R.S.; Sannappa, J.

    2017-01-01

    Radon is a radioactive inert gas, a decay product of radium, causes environmental health problems like lung cancer. Radium present in the earth crest continuously releases radon into underground water. From the point view of health, the study of radon concentration level in underground water base line data is important. In the present study, radon concentration in underground water have been measured in 40 underground water samples collected in and around Kabini River of Karnataka State by using Emanometry technique. The radon concentration in the study area varies from 21.2 to 168.2Bq.l -1 with a geometrical mean value of 73.3 Bq.l -1 . The physicochemical parameters of water such as chloride, Fluoride, nitrite, sulphate, TDS are measured in the same samples in order to know about the impact of these parameters on radon concentration and their health risks to the general public. The experimental techniques and results obtained are discussed in the presentation. (author)

  11. Radon in large buildings: The development of a protocol

    International Nuclear Information System (INIS)

    Wilson, D.L.; Dudney, C.S.; Gammage, R.B.

    1993-01-01

    Over the past several years, considerable research has been devoted by the US Environmental Protection Agency (USEPA) and others to develop radon sampling protocols for single family residences and schools. However, very little research has been performed on measuring radon in the work place. To evaluate possible sampling protocols, 833 buildings throughout the United States were selected for extensive radon testing. The buildings tested (warehouses, production plants and office buildings) were representative of commercial buildings across the country both in design, size and use. Based on the results, preliminary radon sampling protocols for the work place have been developed

  12. A simple bubbling system for measuring radon (222Rn) gas concentrations in water samples based on the high solubility of radon in olive oil.

    Science.gov (United States)

    Al-Azmi, D; Snopek, B; Sayed, A M; Domanski, T

    2004-01-01

    Based on the different levels of solubility of radon gas in organic solvents and water, a bubbling system has been developed to transfer radon gas, dissolving naturally in water samples, to an organic solvent, i.e. olive oil, which is known to be a good solvent of radon gas. The system features the application of a fixed volume of bubbling air by introducing a fixed volume of water into a flask mounted above the system, to displace an identical volume of air from an air cylinder. Thus a gravitational flow of water is provided without the need for pumping. Then, the flushing air (radon-enriched air) is directed through a vial containing olive oil, to achieve deposition of the radon gas by another bubbling process. Following this, the vial (containing olive oil) is measured by direct use of gamma ray spectrometry, without the need of any chemical or physical processing of the samples. Using a standard solution of 226Ra/222Rn, a lowest measurable concentration (LMC) of radon in water samples of 9.4 Bq L(-1) has been achieved (below the maximum contaminant level of 11 Bq L(-1)).

  13. Calibration of track detectors and measurement of radon exhalation rate from solid samples

    International Nuclear Information System (INIS)

    Singh, Ajay Kumar; Jojo, P.J.; Prasad, Rajendra; Khan, A.J.; Ramachandran, T.V.

    1997-01-01

    CR-39 and LR-115 type II track detectors to be used for radon exhalation measurements have been calibrated. The configurations fitted with detectors in Can technique in the open cup mode are cylindrical plastic cup (PC) and conical plastic cup (CPC). The experiment was performed in radon exposure chamber having monodisperse aerosols of 0.2 μm size, to find the relationship between track density and the radon concentration. The calibration factors for PC and CPC type dosimeters with LR-115 type II detector were found to be 0.056 and 0.083 tracks cm -2 d -1 (Bqm -3 ) -1 respectively, while with CR-39 detector the values were 0.149 and 0.150 tracks cm -2 d -1 (Bq m -3 ) -1 . Employing the Can technique, measurements of exhalation rates from solid samples used as construction materials, are undertaken. Radon exhalation rate is found to be minimum in cement samples while in fly ash it is not enhanced as compared to coal samples. (author)

  14. Radon in Finnish dwellings. Sample survey 2006

    International Nuclear Information System (INIS)

    Maekelaeinen, I.; Kinnunen, T.; Reisbacka, H.; Valmari, T.; Arvela, H.

    2009-12-01

    Indoor radon concentration was measured in 2882 dwellings randomly selected by the Population Register Centre of Finland. Radon measurements were made in two half-year periods, the first one lasting from April to November 2006 and the second one from November 2006 to April 2007. Measurements were made using STUK's alpha track detectors. According to the decree 944 / 92 by the Ministry of Social Affairs and Health, the indoor radon concentration should not exceed the 400 Bq /m 3 , whereas new buildings should be built so that 200 Bq /m 3 is not exceeded. In addition, the part D2 of the National Building Code of Finland (Indoor climate and ventilation of buildings) sets 200 Bq /m 3 as a reference value for planning of new buildings. Since 2004, according to the regulation B3 (Foundations), radon should be taken into account in new building in the whole country. A radon technical plan should be included into the building licence application. This plan can be exceptionally ignored only when building in areas where exceeding of 200 Bq / m 3 seldom occurs. In this study the nationwide means weighted by number of inhabitants in provinces in houses and flats were 121 Bq /m 3 and 49 Bq /m 3 , and 96 Bq /m 3 for all dwellings. The percentages of dwellings exceeding 200 Bq /m 3 for houses and flats were 15.1% and 1.5%, and 10.4% for all dwellings. The respective values for the reference value 400 Bq/m 3 were 3.8%, 0.7%, and 2.7%. The numbers of dwellings exceeding 200 Bq /m 3 were 204 000 for houses and 16 000 for flats, respectively. The respective numbers of dwellings exceeding 400 Bq /m 3 were 51 000 and 8.000. The highest radon concentrations were measured in the areas of Tavastia and South-Eastern Finland, in the provinces Eastern Uusimaa, Kymenlaakso, Paeijaenne Tavastia, Tavastia Proper, Pirkanmaa and South Karelia. In these provinces 29 - 51 per cent of small houses exceed 200 Bq /m 3 . The lowest radon concentrations were achieved with a crawl space foundation. Radon

  15. Portable monitors for measuring radon and its progenies air by intergrated sampling method

    International Nuclear Information System (INIS)

    Zhang Huaiqin; Su Jingling; Yao Wanyuan; Liu Jinhua

    1989-01-01

    Two kinds of portable monitors have been developed, which can be used to measure the concentration of radon or potential energy concentration of radon or potential energy concentration of radon progenies in air. The thermoluminescent material CaSO 4 (Tm) is used as a detecting element for both of them. The lowest detectable limit of the passive radon monitor is about 1.5 Bq/m 3 for radon in air, as the exposure time being one week. Its main advantages are high reliability and convenient manipulation. The working level monitor for radon progenies in air consists of a mini membrane pump and an integrating probe. The lowest detectable limit is about 6.2 x 10 -9 J/m 3 , as the sampling time being 6 hours. It weights only about 0.35 kg

  16. Uranium, radium and radon exhalation study in some soil samples using track etch technique

    International Nuclear Information System (INIS)

    Harmanjit, Singh; Joga, Singh; Surinder, Singh; Bajwa, B.S.

    2006-01-01

    Full text of publication follows: Uranium, radium concentration and radon exhalation rates have been determined in the soil samples collected from some areas of Punjab using the L.R.-115 nuclear track detectors. Radium concentration in these samples has been found to be varying from 0.80 to 5.34 Bq Kg-1. The radon exhalation rate in these samples has been found to be varying from 0.99 to 6.60 mBq Kg -1 h -1 (32.82 to 218.49 mBqm -2 h -1 ). A good correlation has been observed between radon exhalation rate and radium concentration observed in the soil samples. The uranium concentration in all these samples is being carried out and the other correlations will also be established. (authors)

  17. Radon in water samples around Ningyo Toge area

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Sadaaki [Power Reactor and Nuclear Fuel Development Corp., Kamisaibara, Okayama (Japan). Ningyo Toge Works

    1997-02-01

    Radon concentrations of river water and drinking water were surveyed. Water samples were collected from the region around Ningyo-Toge Works which were positioned on a granitic layer having uranium deposit. Each sample was taken using a separating funnel and the radioactivity was counted by liquid scintillation counter (ALOKA, LB-2). Since there were old working places of mine in the region, mine drainages from them were also analyzed. The radon concentration of drinking water from the region ranged from 0.1 to 230 Bq/l. The samples with a higher activity than 100 Bq/l were water from springs or wells and the area of the highest Rn concentration was on a typical granitic layer, suggesting some geographic effects on Rn concentration. Some samples of drinking water had slightly higher levels of Rn, probably due to the utilization of underflow as its source. The mean concentration of Rn became higher in the order; river water, drinking water, mine drainage in the region. In addition, a negative correlation between Rn concentration of water and the river flow rate was observed in this region. (M.N.)

  18. Optimized measurement of radium-226 concentration in liquid samples with radon-222 emanation

    International Nuclear Information System (INIS)

    Perrier, Frédéric; Aupiais, Jean; Girault, Frédéric; Przylibski, Tadeusz A.; Bouquerel, Hélène

    2016-01-01

    Measuring radium-226 concentration in liquid samples using radon-222 emanation remains competitive with techniques such as liquid scintillation, alpha or mass spectrometry. Indeed, we show that high-precision can be obtained without air circulation, using an optimal air to liquid volume ratio and moderate heating. Cost-effective and efficient measurement of radon concentration is achieved by scintillation flasks and sufficiently long counting times for signal and background. More than 400 such measurements were performed, including 39 dilution experiments, a successful blind measurement of six reference test solutions, and more than 110 repeated measurements. Under optimal conditions, uncertainties reach 5% for an activity concentration of 100 mBq L"−"1 and 10% for 10 mBq L"−"1. While the theoretical detection limit predicted by Monte Carlo simulation is around 3 mBq L"−"1, a conservative experimental estimate is rather 5 mBq L"−"1, corresponding to 0.14 fg g"−"1. The method was applied to 47 natural waters, 51 commercial waters, and 17 wine samples, illustrating that it could be an option for liquids that cannot be easily measured by other methods. Counting of scintillation flasks can be done in remote locations in absence of electricity supply, using a solar panel. Thus, this portable method, which has demonstrated sufficient accuracy for numerous natural liquids, could be useful in geological and environmental problems, with the additional benefit that it can be applied in isolated locations and in circumstances when samples cannot be transported. - Highlights: • Radium-226 concentration measured with optimized accumulation in a container. • Radon-222 in air measured precisely with scintillation flasks and long countings. • Method tested by repetition tests, dilution experiments, and successful blind tests. • Estimated conservative detection limit without pre-concentration is 5 mBq L"−"1. • Method is portable, cost

  19. Radon testing in schools in New York State: a 20-year summary

    International Nuclear Information System (INIS)

    Kitto, Michael

    2014-01-01

    For nearly 20 years the Department of Health has conducted programs to assist in the measurement and reduction of indoor radon concentrations in 186 schools located primarily in Zone 1 areas of New York State. Although many schools had few or no rooms containing radon above 148 Bq/m 3 , some rooms had >740 Bq/m 3 and remediation techniques were utilized to reduce exposure. Short-term radon measurements in the schools showed little correlation to basement and first-floor radon results from single-family homes in the towns. - Highlights: • Relatively few schools in New York State have been tested for indoor radon. • We provide a summary of radon-testing results for measured schools. • The radon potential in schools is often less than in local houses. • Short-term measurement results exceeded their long-term counterparts in nearly every case

  20. Determination of radon and radium concentrations in drinking water samples around the city of Kutahya

    International Nuclear Information System (INIS)

    Sahin, L.; Cetinkaya, H.; Murat Sac, M.; Ichedef, M.

    2013-01-01

    The concentration of radium and radon has been determined in drinking water samples collected from various locations of Kutahya city, Turkey. The water samples are taken from public water sources and tap water, with the collector chamber method used to measure the radon and radium concentration. The radon concentration ranges between 0.1 and 48.6±1.7 Bq l -1 , while the radium concentration varies from a minimum detectable activity of -1 in Kutahya city. In addition to the radon and radium levels, parameters such as pH, conductivity and temperature of the water, humidity, pressure, elevation and the coordinates of the sampling points have also been measured and recorded. The annual effective dose from radon and radium due to typical water usage has been calculated. The resulting contribution to the annual effective dose due to radon ingestion varies between 0.3 and 124.2 μSv y -1 ; the contribution to the annual effective dose due to radium ingestion varies between 0 and 143.3 μSv y -1 ; the dose contribution to the stomach due to radon ingestion varies between 0.03 and 14.9 μSv y -1 . The dose contribution due to radon inhalation ranges between 0.3 and 122.5 μSv y -1 , assuming a typical transfer of radon in water to the air. For the overwhelming majority of the Kutahya population, it is determined that the average radiation exposure from drinking water is less than 73.6μmSv y -1 . (authors)

  1. Radon concentration and exhalation rates in building material samples from crushing zone in Shivalik Foot Hills

    International Nuclear Information System (INIS)

    Pundir, Anil; Kamboj, Sunil; Bansal, Vakul; Chauhan, R.P.; Rana, Rajinder Singh

    2012-01-01

    Radon ( 222 Rn) is an inert radioactive gas in the decay chain of uranium ( 238 U). It continuously emanates from soil to the atmosphere. Radon and its progeny are the major natural radioactive sources for the ambient radioactivity on Earth. A number of studies on radon were performed in recent decades focusing on its transport and movement in the atmosphere under different meteorological conditions. Building materials are the main source of radon inside buildings. Some construction materials are naturally more radioactive and removal of such material from the earth's crust and their subsequent use in construction of buildings further enhances the radioactivity level. The knowledge of radioactivity level in the building materials makes us aware about the management, guidelines and standards in construction of buildings. The main objective of the present investigations is to measure radon Concentration and exhalation rates in the samples collected from the Crushing zone of Shivalik foot hills. Different types of materials are being used in Northern part of India for construction of dwellings. For the measurement of radon concentration and its exhalation rates in building materials, LR-115 detectors were exposed in closed plastic canisters for three months. At the end of the exposure time, the detectors were subjected to a chemical etching process in 2.5N NaOH solution. The tracks produced by the alpha particles were observed and counted under an optical Olympus microscope at 600X. The measured track density was converted into radon concentration using a calibration factor. The surface and mass exhalation rates of radon have also been calculated using present data. The results indicate that the radon concentration varies appreciably from sample to sample and they were found to satisfy the safety criteria. There are samples in which radon concentration is higher and may enhance the indoor radiation levels when used as building construction materials. (author)

  2. Membrane barriers for radon gas flow restrictions

    International Nuclear Information System (INIS)

    Archibald, J.F.

    1984-08-01

    Research was performed to assess the feasibility of barrier membrane substances, for use within mining or associated high risk environments, in restricting the diffusion transport of radon gas quantities. Specific tests were conducted to determine permeability parameters of a variety of membrane materials with reference to radon flow capabilities. Tests were conducted both within laboratory and in-situ emanation environments where concentrations and diffusion flows of radon gas were known to exist. Equilibrium radon gas concentrations were monitored in initially radon-free chambers adjacent to gas sources, but separated by specified membrane substances. Membrane barrier effectiveness was demonstrated to result in reduced emanation concentrations of radon gas within the sampling chamber atmosphere. Minimum gas concentrations were evidenced where the barrier membrane material was shown to exhibit lowest radon permeability characteristics

  3. Radon emanation from soils

    International Nuclear Information System (INIS)

    Markkanen, M.; Arvela, H.

    1992-01-01

    The results of gamma spectrometric sample measurements of radon ( 222 Rn) emanation coefficients and radium concentrations ( 226 Ra) from about 800 Finnish soil samples are presented. The radon emanation rate was measured in about 400 soil samples, using radon-tight cans and Lucas cells. The effects of water content and temperature on radon emanation were investigated, using various samples of different soil types. Radon emanation and the effect of water content on radon emanation were investigated separately for different grain sizes (samples of till). The results provide some information on radon emanation in different soil types and relate emanation in laboratory conditions to conditions in ground soil. In routine measurements of radon emanation from soil samples, use of a 5% water content was considered advisable. The correction coefficients of radon emanation varied between 0.3 and 1.5, depending on the water content and soil type. At 5% water content, hardly any difference was found between radon emanation at temperatures of 20 and 1 o C. Radon emanation was found to be an inverse function of grain sizes larger than 0.5 mm in diameter. (author)

  4. Stratified random sampling plans designed to assist in the determination of radon and radon daughter concentrations in underground uranium mine atmosphere

    International Nuclear Information System (INIS)

    Makepeace, C.E.

    1981-01-01

    Sampling strategies for the monitoring of deleterious agents present in uranium mine air in underground and surface mining areas are described. These methods are designed to prevent overexposure of the lining of the respiratory system of uranium miners to ionizing radiation from radon and radon daughters, and whole body overexposure to external gamma radiation. A detailed description is provided of stratified random sampling monitoring methodology for obtaining baseline data to be used as a reference for subsequent compliance assessment

  5. Radon prevention in new construction. Sample survey 2009

    International Nuclear Information System (INIS)

    Arvela, H.; Maekelaeinen, I.; Holmgren, O.; Reisbacka, H.

    2010-05-01

    The building code for radon prevention and the associated practical guidelines were revised in Finland in 2003 to 2004. Thereafter, preventive measures have become more common and prevention practices more effective. Consequently, indoor radon concentrations in new construction have been markedly reduced. In this study, the indoor radon concentration was measured in 1 500 new lowrise residential houses. The houses were randomly selected and represented 7 % of houses that received building permission in 2006. The average radon concentration of all houses measured, which were completed in 2006 to 2008, was 95 Bq/m 3 , the median being 58 Bq/m 3 . The average was 30 % lower than in houses completed in 2000 to 2005. The decrease was 50 % in provinces with the highest indoor radon concentration and 20 % elsewhere in the country. In houses with a slab-on-ground foundation that had both passive radon piping and sealing measures carried out using a strip of bitumen felt in the joint between the foundation wall and floor slab, the radon concentration was on average reduced by 55 % compared to houses with no preventive measures. Preventive measures were taken in 50 % of single family houses, and in provinces with the highest radon concentration in 90 % of houses. Active prevention in areas with high indoor radon concentrations has reduced the regional differences in the radon concentration. Slab on ground is the prevailing type of foundation and necessitates careful radon prevention measures throughout the country. The most serious defects were observed in prevention practices in houses with walls made of lightweight concrete blocks that were in contact with soil. The foundation types with the lowest radon concentrations were those with a crawl space and a monolithic slab. (orig.)

  6. Radon exhalation and its dependence on moisture content from samples of soil and building materials

    International Nuclear Information System (INIS)

    Faheem, Munazza; Matiullah

    2008-01-01

    Indoor radon has long been recognized as a potential health hazard for mankind. Building materials are considered as one of the major sources of radon in the indoor environment. To study radon exhalation rate and its dependence on moisture content, samples of soil and some common types of building materials (sand, cement, bricks and marble) were collected from Gujranwala, Gujrat, Hafizabad, Sialkot, Mandibahauddin and Narowal districts of the Punjab province (Pakistan). After processing, samples of 200 g each were placed in plastic vessels. CR-39 based NRPB detector were placed at the top of these vessels and were then hermetically sealed. After exposing to radon for 30 days within the closed vessels, the CR-39 detectors were processed. Radon exhalation rate was found to vary from 122±19 to 681±10mBqm -2 h -1 with an average of 376±147mBqm -2 h -1 in the soil samples whereas an average of 212±34, 195±25, 231±30 and 292±35mBqm -2 h -1 was observed in bricks, sand, cement and marble samples, respectively. Dependence of exhalation on moisture content has also been studied. Radon exhalation rate was found to increase with an increase in moisture, reached its maximum value and then decreased with further increase in the water content

  7. Estimation of radon concentration in soil and groundwater samples of Northern Rajasthan, India

    Directory of Open Access Journals (Sweden)

    Sudhir Mittal

    2016-04-01

    Full Text Available In the present investigation, analysis of radon concentration in 20 water and soil samples collected from different locations of Bikaner and Jhunjhunu districts of Rajasthan, India has been carried out by using RAD7 an electronic Radon detector. The measured radon concentration in water samples lies in the range from 0.50 to 22 Bq l−1 with the mean value of 4.42 Bq l−1, which lies within the safe limit from 4 to 40 Bq l−1 recommended by United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR, 2008. The total annual effective dose estimated due to radon concentration in water ranges from 1.37 to 60.06 μSV y−1 with the mean value of 12.08 μSV y−1, which is lower than the safe limit 0.1 mSv y−1 as set by World Health Organization (WHO, 2004 and European Council (EU, 1998. Radon measurement in soil samples varies from 941 to 10,050 Bq m−3 with the mean value of 4561 Bq m−3, which lies within the range reported by other investigators. It was observed that the soil and water of Bikaner and Jhunjhunu districts are suitable for drinking and construction purpose without posing any health hazard.

  8. Analysis of separation test for automatic brake adjuster based on linear radon transformation

    Science.gov (United States)

    Luo, Zai; Jiang, Wensong; Guo, Bin; Fan, Weijun; Lu, Yi

    2015-01-01

    The linear Radon transformation is applied to extract inflection points for online test system under the noise conditions. The linear Radon transformation has a strong ability of anti-noise and anti-interference by fitting the online test curve in several parts, which makes it easy to handle consecutive inflection points. We applied the linear Radon transformation to the separation test system to solve the separating clearance of automatic brake adjuster. The experimental results show that the feature point extraction error of the gradient maximum optimal method is approximately equal to ±0.100, while the feature point extraction error of linear Radon transformation method can reach to ±0.010, which has a lower error than the former one. In addition, the linear Radon transformation is robust.

  9. Radon detection system, design, test and performance

    International Nuclear Information System (INIS)

    Balcazar, M.; Chavez, A.; Pina-Villalpando, G.; Navarrete, M.

    1999-01-01

    A portable radon detection system (α-Inin) has been designed and constructed for using it in adverse environmental conditions where humidity, temperature and chemical vaporous are present. The minimum integration time is in periods of 15 min during 41 days. A 12 V battery and a photovoltaic module allow the α-Inin autonomy in field measurements. Data is collected by means of a laptop computer where data processing and α-Inin programming are carried out. α-Inin performance was simultaneously tested in a controlled radon chamber, together with a commercial α-Meter

  10. Calibration of diffusion barrier charcoal detectors and application to radon sampling in dwellings

    International Nuclear Information System (INIS)

    Montero C, M.E.; Colmenero S, L.; Villalba, L.; Saenz P, J.; Cano J, A.; Moreno B, A.; Renteria V, M.; Herrera P, E.F.; Cruz G, S. De la; Lopez M, A.

    2003-01-01

    Some calibration conditions of diffusion barrier charcoal canister (DBCC) detectors for measuring radon concentration in air were studied. A series of functional expressions and graphs were developed to describe relationship between radon concentration in air and the activity adsorbed in DBCC, when placed in small chambers. A semi-empirical expression for the DBCC calibration was obtained, based on the detector integration time and the adsorption coefficient of radon on activated charcoal. Both, the integration time for 10 % of DBCC of the same batch, and the adsorption coefficient of radon for the activated charcoal used in these detectors, were experimentally determined. Using these values as the calibration parameters, a semi-empirical calibration function was used for the interpretation of the radon activities in the detectors used for sampling more than 200 dwellings in the major cities of the state of Chihuahua, Mexico. (Author)

  11. Calibration of diffusion barrier charcoal detectors and application to radon sampling in dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Montero C, M.E.; Colmenero S, L.; Villalba, L.; Saenz P, J.; Cano J, A.; Moreno B, A.; Renteria V, M.; Herrera P, E.F. [Cento de Investigacion en Materiales Avanzados, S. C. Miguel de Cervantes 120, Complejo Industrial Chihuahua, Chihuahua, (Mexico); Cruz G, S. De la [Facultad de Enfermeria y Nutriologia, Universidad Autonoma de Chihuahua, Av. Politecnico Nacional 2714, Chihuahua, (Mexico); Lopez M, A. [Instituto Nacional de Investigaciones Nucleares, Apartado Postal 18-1027, 11801 Mexico D.F. (Mexico)

    2003-07-01

    Some calibration conditions of diffusion barrier charcoal canister (DBCC) detectors for measuring radon concentration in air were studied. A series of functional expressions and graphs were developed to describe relationship between radon concentration in air and the activity adsorbed in DBCC, when placed in small chambers. A semi-empirical expression for the DBCC calibration was obtained, based on the detector integration time and the adsorption coefficient of radon on activated charcoal. Both, the integration time for 10 % of DBCC of the same batch, and the adsorption coefficient of radon for the activated charcoal used in these detectors, were experimentally determined. Using these values as the calibration parameters, a semi-empirical calibration function was used for the interpretation of the radon activities in the detectors used for sampling more than 200 dwellings in the major cities of the state of Chihuahua, Mexico. (Author)

  12. Correlation between radon exhalation and radium content in granite samples used as construction material in Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: mibrahim@kfupm.edu.sa; Fazal-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Musazay, M.S. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Aksoy, A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-11-15

    Measurements of radon exhalation for a total of 205 selected samples of construction materials used in Saudi Arabia were carried out using an active radon gas analyzer with an emanation container. It was found that granite samples were the main source of radon exhalation. The radon exhalation rates per unit area from these granite samples varied from below the minimum detection limit up to 13.1Bqm{sup -2}h{sup -1} with an average of 1.5 +/-1.9(1{sigma})Bqm{sup -2}h{sup -1}. The radium contents of 27 granite samples were measured using an HPGe-based {gamma} spectroscopy setup. The {sup 226}Ra content of the granites varied from below the minimum detection limit up to 297Bqkg{sup -1}, with an average of 83+/-73(1{sigma})Bqkg{sup -1}. The linear correlation coefficient between exhaled radon and radium content was found to be 0.90.

  13. Evaluation of radon occurrence in groundwater from 16 geologic units in Pennsylvania, 1986–2015, with application to potential radon exposure from groundwater and indoor air

    Science.gov (United States)

    Gross, Eliza L.

    2017-05-11

    Results from 1,041 groundwater samples collected during 1986‒2015 from 16 geologic units in Pennsylvania, associated with 25 or more groundwater samples with concentrations of radon-222, were evaluated in an effort to identify variations in radon-222 activities or concentrations and to classify potential radon-222 exposure from groundwater and indoor air. Radon-222 is hereafter referred to as “radon.” Radon concentrations in groundwater greater than or equal to the proposed U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) for public-water supply systems of 300 picocuries per liter (pCi/L) were present in about 87 percent of the water samples, whereas concentrations greater than or equal to the proposed alternative MCL (AMCL) for public water-supply systems of 4,000 pCi/L were present in 14 percent. The highest radon concentrations were measured in groundwater from the schists, gneisses, and quartzites of the Piedmont Physiographic Province.In this study, conducted by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Health and the Pennsylvania Department of Environmental Protection, groundwater samples were aggregated among 16 geologic units in Pennsylvania to identify units with high median radon concentrations in groundwater. Graphical plots and statistical tests were used to determine variations in radon concentrations in groundwater and indoor air. Median radon concentrations in groundwater samples and median radon concentrations in indoor air samples within the 16 geologic units were classified according to proposed and recommended regulatory limits to explore potential radon exposure from groundwater and indoor air. All of the geologic units, except for the Allegheny (Pa) and Glenshaw (Pcg) Formations in the Appalachian Plateaus Physiographic Province, had median radon concentrations greater than the proposed EPA MCL of 300 pCi/L, and the Peters Creek Schist (Xpc), which is in the Piedmont

  14. ERRICCA radon model intercomparison exercise

    International Nuclear Information System (INIS)

    Andersen, C.E.; Albarracin, D.; Csige, I.; Graaf, E.R. van der; Jiranek, M.; Rehs, B.; Svoboda, Z.; Toro, L.

    1999-04-01

    Numerical models based on finite-difference or finite-element methods are used by various research groups in studies of radon-222 transport through soil and building materials. Applications range from design of radon remediation systems to more fundamental studies of radon transport. To ascertain that results obtained with these models are of good quality, it is necessary that such models are tested. This document reports on a benchmark test organized by the EU project ERRICCA: European Research into Radon in Construction Concerted Action. The test comprises the following cases: 1) Steady-state diffusive radon profiles in dry and wet soils, 2) steady-state entry of soil gas and radon into a house, 3) time-dependent radon exhalation from a building-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive transport of radon, flux calculations, and partitioning of radon between air and water in soil pores. Seven groups participated in the intercomparison. All groups submitted results without knowing the results of others. For these results, relatively large group-to-group discrepancies were observed. Because of this, all groups scrutinized their computations (once more) and engaged in follow-up discussions with others. During this debugging process, problems were indeed identified (and eliminated). The accordingly revised results were in better agreement than those reported initially. Some discrepancies, however, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommended that additional exercises are carried out. (au)

  15. Radon Concentration And Dose Assessment In Well Water Samples From Karbala Governorate Of Iraq

    Science.gov (United States)

    Al-Alawy, I. T.; Hasan, A. A.

    2018-05-01

    There are numerous studies around the world about radon concentrations and their risks to the health of human beings. One of the most important social characteristics is the use of water wells for irrigation, which is a major source of water pollution with radon gas. In the present study, six well water samples have been collected from different locations in Karbala governorate to investigate radon concentration level using CR-39 technique. The maximum value 4.112±2.0Bq/L was in Al-Hurr (Al-Qarih Al-Easariah) region, and the lowest concentration of radon was in Hay Ramadan region which is 2.156±1.4Bq/L, with an average value 2.84±1.65Bq/L. The highest result of annual effective dose (AED) was in Al-Hurr (Al-Qarih Al-Easariah) region which is equal to 15.00±3.9μSv/y, while the minimum was recorded in Hay Ramadan 7.86±2.8μSv/y, with an average value 10.35±3.1μSv/y. The current results have shown that the radon concentrations in well water samples are lower than the recommended limit 11.1Bq/L and the annual effective dose in these samples are lower than the permissible international limit 1mSv/y.

  16. Use of commercial radon monitors for low level radon measurements in dynamically operated VOC emission test chambers

    International Nuclear Information System (INIS)

    Hofmann, M.; Richter, M.; Jann, O.

    2017-01-01

    Compared to the intended EU reference level of 300 Bq m -3 for indoor radon concentrations, the contribution of building materials appears to be low. Considering the recommended limit of 100 Bq m -3 by WHO, their contribution is supposed to be relevant, especially at low air exchange rates. This study as part of a two-part research project investigated the suitability of direct low level 222 Rn measurement under simulated indoor conditions with commercial radon monitors and dynamically operated emission test chambers. Active measuring devices based on ionisation or scintillation chambers with 1-σ uncertainties below 8.6% at 20 Bq m -3 were found to be best suitable for a practical test procedure for the determination of radon exhalation rates of building materials. For the measurement of such low concentrations, the knowledge of the accurate device background level is essential. (authors)

  17. Wind direction correlated measurements of radon and radon progeny in atmosphere: a method for radon source identification

    International Nuclear Information System (INIS)

    Akber, R.A.; Pfitzner, J.; Johnston, A.

    1994-01-01

    This paper describes the basic principles and methodology of a wind direction correlated measurement technique which is used to distinguish the mine-related and background components of radon and radon progeny concentrations in the vicinity of the ERA Ranger Uranium Mine. Simultaneous measurements of atmospheric radon and radon progeny concentrations and wind speed and direction were conducted using automatic sampling stations. The data were recorded as a time series of half hourly averages and grouped into sixteen 22.5 degrees wind sectors. The sampling interval and the wind sector width were chosen considering wind direction variability (σ θ ) over the sampling time interval. The data were then analysed for radon and radon progeny concentrations in each wind sector. Information about the wind frequency wind speed seasonal and diurnal variations in wind direction and radon concentrations was required for proper data analysis and interpretation of results. A comparison with model-based estimates for an identical time period shows agreement within about a factor of two between the two methods. 15 refs., 1 tab., 5 figs

  18. Intercomparison of active and passive instruments for radon and radon progeny in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng-Wu; Knutson, E.O.

    1995-02-01

    An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- and beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within ±10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement

  19. Radon analyser

    International Nuclear Information System (INIS)

    1981-01-01

    The process claimed includes the steps of transferring radon gas produced by a sample to a charcoal trap, cooled to a temperature whereby the radon is absorbed by the charcoal, heating the charcoal trap to a sufficient temperature to release the radon, and transferring the radon to a counting device where the gas particles are counted

  20. Continuous monitoring systems for indoor radon measurement: construction and results of their testing

    International Nuclear Information System (INIS)

    Muellerova, M.; Holy, K.; Bujnova, A.; Polaskova, A.; Hola, O.

    2007-01-01

    Two continuous radon monitoring systems were built on the basis of the scintillation chambers. The first system used the large volume scintillation chamber with the volume of 4.5 liters and the second one the commercial scintillation chamber with the volume of 1 liter as the detectors for radon concentration measurement. Both systems were calibrated by Ward-Borak method. The detection limits of monitoring systems are 2.9 Bq · m -3 and 5.1 Bq · m -3 respectively, at -2 hour counting period and 30 % statistical uncertainty. The radon monitoring systems and the professional radon monitor AlphaGUARD were tested in real conditions of working room. The testing showed that long-tenn courses of radon activity concentrations obtained by all three monitors are highly correlated (R 2 ∼0.95). Also the average values of radon activity concentrations calculated on the basis of measured data are identical in the scope of counting errors already at the measurement of the radon activity concentrations in the range of (10-120) Bq · m -3 . (authors)

  1. A model to predict radon exhalation from walls to indoor air based on the exhalation from building material samples

    International Nuclear Information System (INIS)

    Sahoo, B.K.; Sapra, B.K.; Gaware, J.J.; Kanse, S.D.; Mayya, Y.S.

    2011-01-01

    In recognition of the fact that building materials are an important source of indoor radon, second only to soil, surface radon exhalation fluxes have been extensively measured from the samples of these materials. Based on this flux data, several researchers have attempted to predict the inhalation dose attributable to radon emitted from walls and ceilings made up of these materials. However, an important aspect not considered in this methodology is the enhancement of the radon flux from the wall or the ceiling constructed using the same building material. This enhancement occurs mainly because of the change in the radon diffusion process from the former to the latter configuration. To predict the true radon flux from the wall based on the flux data of building material samples, we now propose a semi-empirical model involving radon diffusion length and the physical dimensions of the samples as well as wall thickness as other input parameters. This model has been established by statistically fitting the ratio of the solution to radon diffusion equations for the cases of three-dimensional cuboidal shaped building materials (such as brick, concrete block) and one dimensional wall system to a simple mathematical function. The model predictions have been validated against the measurements made at a new construction site. This model provides an alternative tool (substitute to conventional 1-D model) to estimate radon flux from a wall without relying on 226 Ra content, radon emanation factor and bulk density of the samples. Moreover, it may be very useful in the context of developing building codes for radon regulation in new buildings. - Research highlights: → A model is proposed to predict radon flux from wall using flux of building material. → It is established based on the diffusion mechanism in building material and wall. → Study showed a large difference in radon flux from building material and wall. → Model has been validated against the measurements made at

  2. Uncertainties of estimating average radon and radon decay product concentrations in occupied houses

    International Nuclear Information System (INIS)

    Ronca-Battista, M.; Magno, P.; Windham, S.

    1986-01-01

    Radon and radon decay product measurements made in up to 68 Butte, Montana homes over a period of 18 months were used to estimate the uncertainty in estimating long-term average radon and radon decay product concentrations from a short-term measurement. This analysis was performed in support of the development of radon and radon decay product measurement protocols by the Environmental Protection Agency (EPA). The results of six measurement methods were analyzed: continuous radon and working level monitors, radon progeny integrating sampling units, alpha-track detectors, and grab radon and radon decay product techniques. Uncertainties were found to decrease with increasing sampling time and to be smaller when measurements were conducted during the winter months. In general, radon measurements had a smaller uncertainty than radon decay product measurements. As a result of this analysis, the EPA measurements protocols specify that all measurements be made under closed-house (winter) conditions, and that sampling times of at least a 24 hour period be used when the measurement will be the basis for a decision about remedial action or long-term health risks. 13 references, 3 tables

  3. The use of mechanical ventilation with heat recovery for controlling radon and radon-daughter concentrations

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Boegel, M.L.; Hollowell, C.D.; Roseme, G.D.

    1980-01-01

    An energy research house in Maryland was found to have radon concentrations far in excess of recommended guidelines. A mechanical ventilation system with heat recovery was installed in this house to test its effectiveness as an energy-efficient control technique for indoor radon. Radon concentration was monitored continuously for two weeks under varying ventilation conditions (0.07 to 0.8 air changes per hour (ach)) and radon daughter concentrations were measured by grab-sample techniques about nine times daily during this period. At ventilation rates of 0.6 ach and higher radon and radon daughter levels dropped below guidelines for indoor concentrations. Comparison with other studies indicates that indoor radon buildup may be a problem in a considerable portion of houses characterized by their low infiltration rates. The use of mechanical ventilation systems with air-to-air heat exchangers may offer a practical, cost-effective, and energy-efficient means of alleviating not only the radon problem specifically but also the general deterioration of indoor air quality in houses designed or retrofitted to achieve low infiltration

  4. Removing efficiency of radon from water by different methods

    International Nuclear Information System (INIS)

    Muellerova, M.; Holy, K.; Gulasova, Z.; Polaskova, A.

    2008-01-01

    In this contribution problem of radon removing from water samples by different methods was tested. Lowest efficiency of deemanation was achieved at tossing of water from one vessel into the other. For increasing of efficiency deemanation of radon use of needle-bath principle was also used. Low efficiency deemanation was found at trapping of radon from sample of water by toluene (83 ± 5) %, too. Reversal highest efficiency deemanation of radon from water was reached at aerating by argon (95 ± 6)%. It is shown, that reduction of volume activity of radon in water under 0.1 Bq/dm l - 3 is big problem. Suppression of this limit will claim use of more completion and sophistic approaches. (author)

  5. An active radon sampling device for high humidity places

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F. [Department of Nuclear Engineering and Fluid Mechanics, University of the Basque Country (UPV/EHU), Alameda Urquijo s/n 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Department of Nuclear Engineering and Fluid Mechanics, University of the Basque Country (UPV/EHU), Alameda Urquijo s/n 48013 Bilbao (Spain); Alegria, N.; Herranz, M. [Department of Nuclear Engineering and Fluid Mechanics, University of the Basque Country (UPV/EHU), Alameda Urquijo s/n 48013 Bilbao (Spain)

    2010-01-15

    An active radon measurement device has been developed to be used in workplaces with a relative humidity of 100% for spot measurements of radon concentration. A mathematical model based on the convective-diffusive transport equation is used in the design of this system, which has been used to measure the radon concentration in the Pozalagua cave (Biscay, at Northern of Spain). From the obtained radon values the public and workers doses have been obtained.

  6. Development of apparatus and procedures for evaluating radon-resistant construction materials

    International Nuclear Information System (INIS)

    Pugh, T.D.; Greenfield, M.B.; MacKenzie, J.; Meijer, R.J. de

    1992-01-01

    Laboratory facilities and apparatus have been constructed to measure radon exhalation from, and radon permeability through, various construction materials. This phase of the project has focused on development of test apparatus and evaluation of instrumentation. Results indicate significant spatial variability in the radon permeability of polyethylene, even when all test samples were selected from the same roll of material, and when no visible differentiation could be made regarding sample quality. Implications for code enforcement are described, and recommendations are offered for refinement of equipment and the measurement process, prioritization of future materials testing, and specific building code provisions, based on our results

  7. Measurement of radon activity, exhalation rate and radiation dose in fly ash and coal samples from NTPC, Badarpur, Delhi, India

    International Nuclear Information System (INIS)

    Gupta, Mamta; Verma, K.D.; Mahur, A.K.; Prasad, R.; Sonkawade, R.G.

    2013-01-01

    In the present study radon activities and exhalation rates from fly ash and coal samples from NTPC (National Thermal Power Corporation) situated at Badarpur, Delhi, India, have been measured. 'Sealed Can Technique' using LR-115 type II track detectors was employed. In fly ash samples, radon activity has been found to vary from 400.0 ± 34.7 to 483.9 ± 38.1Bqm -3 with an average value of 447.1 ± 36.6 Bqm -3 and in coal samples, radon activity has been found to vary from 504.0 ± 39.0 to 932.1 ± 52.9 Bqm -3 with an average value of 687.2 ± 45.2 Bqm -3 . Radon exhalation rate from coal is found to be higher than radon exhalation rate from its ash products, whereas the opposite is expected. Indoor inhalation exposure (radon) effective dose has also been estimated. (author)

  8. Radon/radon-daughter measurement methods and instrumentation

    International Nuclear Information System (INIS)

    Rock, R.L.

    1977-01-01

    Radon-daughter measurement equipment and techniques have been continuously improved over the last 25 years. Improvements have been in the areas of accuracy, time and convenience. We now have miniaturized scalers and detectors available for measuring the alpha particle count rates from aerosol samples collected on filter papers. We also have small lightweight efficient pumps for conveniently collecting samples and we have various counting methods which allow us to choose between making very precise measurements or nominal measurements. Radon-daughter measurement methods used in uranium mines and mills are discussed including a personal radon-daughter-exposure integrating device which can be worn by miners

  9. Radon removal equipment based on aeration: A literature study of tests performed in Sweden between 1981 and 1996

    International Nuclear Information System (INIS)

    Mjoenes, L.

    2000-02-01

    In Sweden some principles to reduce the radon concentration in drinking water were tested in the beginning of the 1980s. Spray aeration under atmospheric pressure, diffused bubble aeration, aeration in the pressure tank and different combinations of these principles were studied. Aeration in the drill hole and adsorption on granulated activated char-coal were also tested. The best results, about 70 % reduction, were obtained with aeration in the pressure tank with a spray system combined with diffused air bubbling. The Oerebro project in the beginning of the 1990s included on site testing of five different aeration solutions: Aeration in the drill hole, aeration in the storage tank, ejector aeration, shallow tray aeration and packed column aeration. The radon removal efficiency varied between 20 % and 99 %. In 1994 a study intended to test the radon removal capacity of different water treatment equipment was performed. Six units of radon separators were included but most of the tested equipment was installed for other water treatment purposes. The performed measurements showed that the only types of equipment that reduce the radon concentration efficiently are radon separators and reverse osmosis filters. The radon removal capacity of the radon separators varied between 23 % and 97 %. In 1996 the nine most common radon separators on the Swedish market were tested. The results showed that the tested radon removal equipment worked well, although the technical quality and chosen technical solutions were not always the best. The radon removal capacity of the units participating in this test was in most cases between 96 and 99 %. In some cases the capacity exceeded 99 %. In order to reach this radon removal capacity the water must be recirculated in a storage tank under atmospheric pressure

  10. Radon removal equipment based on aeration: A literature study of tests performed in Sweden between 1981 and 1996

    Energy Technology Data Exchange (ETDEWEB)

    Mjoenes, L

    2000-02-01

    In Sweden some principles to reduce the radon concentration in drinking water were tested in the beginning of the 1980s. Spray aeration under atmospheric pressure, diffused bubble aeration, aeration in the pressure tank and different combinations of these principles were studied. Aeration in the drill hole and adsorption on granulated activated char-coal were also tested. The best results, about 70 % reduction, were obtained with aeration in the pressure tank with a spray system combined with diffused air bubbling. The Oerebro project in the beginning of the 1990s included on site testing of five different aeration solutions: Aeration in the drill hole, aeration in the storage tank, ejector aeration, shallow tray aeration and packed column aeration. The radon removal efficiency varied between 20 % and 99 %. In 1994 a study intended to test the radon removal capacity of different water treatment equipment was performed. Six units of radon separators were included but most of the tested equipment was installed for other water treatment purposes. The performed measurements showed that the only types of equipment that reduce the radon concentration efficiently are radon separators and reverse osmosis filters. The radon removal capacity of the radon separators varied between 23 % and 97 %. In 1996 the nine most common radon separators on the Swedish market were tested. The results showed that the tested radon removal equipment worked well, although the technical quality and chosen technical solutions were not always the best. The radon removal capacity of the units participating in this test was in most cases between 96 and 99 %. In some cases the capacity exceeded 99 %. In order to reach this radon removal capacity the water must be recirculated in a storage tank under atmospheric pressure.

  11. Development and testing of the detector for monitoring radon double-filter method

    International Nuclear Information System (INIS)

    Sevcik, P.

    2008-01-01

    Applications of physics in the study of radon transport processes in the atmosphere and of testing of atmospheric transport models require sensitive detection devices with low maintenance requirements. The most precise devices involved in the worldwide monitoring program of the atmosphere (GAW) determine volume activity of radon from a variety of daughter products of 222 Rn, resulting in a working volume of the detector (double-filter method). The purpose of this work was to explore theoretically and experimentally the possibilities and limits of a particular simple implementation of this procedure. Tested apparatus consists of a 200 dm 3 chamber (metal drum), where are developed transformation products of radon and semiconductor detector with surface barrier, which registers α particles from the conversion of daughter products 222 Rn collected on a filter at the outlet of the chamber. Testing of the apparatus takes place in the atmosphere with higher concentrations of radon. The measured variations of volume activities 222 Rn have the same character as the variations of radon concentration in the air in laboratory. Minimum detectable activity at 95% significance level is 16.0 Bq.m -3 at a pumping speed of the air 20 dm 3 .min - 1 and 13.0 Bq.m -3 at a pumping rate 24 dm 3 .min -1 . These values are still too high for using the apparatus for measuring in external atmosphere. The main limit of the apparatus is a capture of transformation products arising on the inner walls of the chamber (plate-out effect). The effectiveness of collecting 218 Po from the chamber on the filter in our measurements was only 2.8%. But we managed to increase it to about 20% by adding aerosol delivery systems into production chamber of transformation products of radon. It turns out that based on this principle can be made sensitive and continuously working monitor of radon. (author)

  12. Application of single-chip microcomputer to portable radon and radon daughters monitor

    International Nuclear Information System (INIS)

    Meng Yecheng; Huang Zhanyun; She Chengye

    1992-01-01

    Application of single-chip microcomputer to portable radon and radon daughters monitor is introduced in this paper. With the single-chip microcomputer automation comes into effect in the process from sampling to measuring of radon and radon daughters. The concentrations of radon and radon daughters can be easily shown when the conversion coefficients are pre-settled before the measurement. Moreover, the principle and design are briefly discussed according to the characteristics of the monitor

  13. Testing of indoor radon reduction techniques in eastern Pennsylvania: An update

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1987-01-01

    EPA has installed radon reduction measures in 38 houses in the Reading Prong region of eastern Pennsylvania. All were basement houses with hollow block or poured concrete foundation walls. The reduction approaches tested in most houses involved active soil ventilation, including: suction on the footing drain tile system; suction underneath the concrete slabs, using pipes inserted through the slabs from inside the house; and ventilation of the void network inside hollow block foundation walls. Heat recovery ventilators (HRVs) were tested in three houses. The current results confirm that, for the houses tested here, drain tile suction appears consistently able to provide high radon reductions when a complete loop of drain tile exists, often reducing high-radon houses to 4 pCi/l (148 B1/m 3 ) and less. Sub-slab suction (with pipes through the slab) can also provide high reductions if a sufficient number of suction pipes are located properly. Placement of one or more sub-slab suction pipes near each perimeter wall appears in this testing to aid in treating the major soil gas entry routes, although fewer pipes can sometimes give high reductions if conditions are favorable. For effective radon reduction using any active soil ventilation technique, it is important that major wall and slab openings be closed, and that a fan be employed that is capable of developing adequate static pressure

  14. Radon barrier field-test monitoring at Grand Junction tailings pile

    International Nuclear Information System (INIS)

    Freeman, H.D.; Hartley, J.N.; Gee, G.W.

    1983-11-01

    Pacific Northwest Laboratory (PNL), as part of the Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) technology development program, has conducted three large-scale field tests of radon covers at the uranium mill tailings pile in Grand Junction, Colorado. The barrier systems, monitored for radon flux for over two years, include earthen, multilayer, and asphalt emulsion covers. Results of the monitoring have shown that a variety of cover systems can meet the Environmental Protection Agency (EPA) standard. The most effective covers tested were asphalt emulsion and earthen (mancos shale). 10 references, 7 figures, 1 table

  15. Measurement of radon concentration in water using the portable radon survey meter.

    Science.gov (United States)

    Yokoyama, S; Mori, N; Shimo, M; Fukushi, M; Ohnuma, S

    2011-07-01

    A measurement method for measuring radon in water using the portable radon survey meter (RnSM) was developed. The container with propeller was used to stir the water samples and release radon from the water into the air in a sample box of the RnSM. In this method, the measurement of error would be water was >20 Bq l(-1).

  16. Managing Radon in Schools

    Science.gov (United States)

    EPA recommends testing all schools for radon. As part of an effective IAQ management program, schools can take simple steps to test for radon and reduce risks to occupants if high radon levels are found.

  17. Determination of radon exhalation from construction materials using VOC emission test chambers.

    Science.gov (United States)

    Richter, M; Jann, O; Kemski, J; Schneider, U; Krocker, C; Hoffmann, B

    2013-10-01

    The inhalation of (222) Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available measuring devices in combination with VOC emission test chambers. Five materials - two types of clay brick, clinker brick, light-weight concrete brick, and honeycomb brick - generally used for wall constructions were used for the experiments. Their contribution to real room concentrations was estimated by applying room model parameters given in ISO 16000-9, RP 112, and AgBB. This knowledge can be relevant, if for instance indoor radon concentration is limited by law. The test set-up used here is well suited for application in test laboratories dealing with VOC emission testing. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Radon and radon daughters' concentration in spring and wells waters from Presidente Prudente: preliminary results

    International Nuclear Information System (INIS)

    Osorio, Ana Maria Araya; Saenz, Carlos Alberto Tello; Pereira, Luiz Augusto Stuani

    2009-01-01

    This work presents the preliminary results about the concentration of radon and radon daughters in wells and springs water from Presidente Prudente. Six water samples were studied: three from well-water, two from springs water and one from potable water. For the determination of α-activity the samples were placed inside plastic containers where the CR-39 tracks detectors were outside the water. The track density of α-particles were measured by using optical microscopy. The results show that one sample from well-water presented higher concentration of radon and radon daughters than the other samples. (author)

  19. Functional test of a Radon sensor based on a high-resistivity-silicon BJT detector

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Betta, G.F., E-mail: dallabe@disi.unitn.it [DISI, Università di Trento, and INFN Trento, Trento (Italy); RSens srl, Modena (Italy); Tyzhnevyi, V. [DISI, Università di Trento, and INFN Trento, Trento (Italy); Bosi, A.; Bonaiuti, M. [RSens srl, Modena (Italy); Angelini, C.; Batignani, G.; Bettarini, S.; Bosi, F.; Forti, F.; Giorgi, M.A.; Morsani, F.; Paoloni, E.; Rizzo, G.; Walsh, J. [Dipartimento di Fisica, Università di Pisa, and INFN Pisa, Pisa (Italy); Lusiani, A. [Scuola Normale Superiore and INFN Pisa, Pisa (Italy); Ciolini, R.; Curzio, G.; D' Errico, F.; Del Gratta, A. [Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Università di Pisa, Pisa (Italy); Bidinelli, L. [En and tech, Università di Modena e Reggio Emilia, Reggio Emilia (Italy); RSens srl, Modena (Italy); and others

    2013-08-01

    A battery-powered, wireless Radon sensor has been designed and realized using a BJT, fabricated on a high-resistivity-silicon substrate, as a radiation detector. Radon daughters are electrostatically collected on the detector surface. Thanks to the BJT internal amplification, real-time α particle detection is possible using simple readout electronics, which records the particle arrival time and charge. Functional tests at known Radon concentrations, demonstrated a sensitivity up to 4.9 cph/(100 Bq/m{sup 3}) and a count rate of 0.05 cph at nominally-zero Radon concentration.

  20. Perceived susceptibility and self-protective behavior: a field experiment to encourage home radon testing

    International Nuclear Information System (INIS)

    Weinstein, N.D.; Sandman, P.M.; Roberts, N.E.

    1991-01-01

    Tested in a field experiment (N = 647) the hypothesis that perceptions of personal susceptibility are important in decisions to test one's home for radioactive radon gas. Experimental group subjects received a personal telephone call to tell them they lived in a high-risk area and a personal letter to reinforce the telephone message. After the intervention, experimental subjects were significantly more likely than minimal-treatment subjects to acknowledge the possibility of high radon levels in their homes. Perceptions of susceptibility and illness severity were significantly correlated with orders of radon test kits and with testing intentions. Nevertheless, there were no differences between groups in test orders or intentions. Results are discussed in terms of the difficulty of getting people to acknowledge susceptibility and the factors other than risk perceptions that influence self-protective behavior

  1. Construction of radon/radon daughter calibraton chamber

    International Nuclear Information System (INIS)

    Fry, J.; Gan, T.H.; Leach, V.A.; Saddlier, J.; Solomon, S.B.; Tam, K.K.; Travis, E.; Wykes, P.

    1983-01-01

    The radon/radon daughter test chamber is a copper lined room 1.65x1.75x2.75m with an effective volume of 8000 litres. The air residence time is controlled by circulating the air in the chamber through absolute filters which remove 99.9% of particulates. Radon is drawn into the chamber from a 17 μCi 226 RaCl source using the pressure differential across the blowers (<3 psi)

  2. Emanation of radon-222 in uraniferous phosphorite from Pernambuco, Brazil

    International Nuclear Information System (INIS)

    Santos, M.L.O.; França, E.J.; Amaral, D.S.; Silva, K.E.M.; Hazin, C.A.; Farias, E.E.G.

    2017-01-01

    The concentration of radon-222 activity available for transport to the surface through the pore space can be defined as radon emanation. From the decay of radium-226, whose half-life is 1850 years, it is associated with the development of neoplasia, such as lung cancer. In the Metropolitan Region of Recife, sedimentary rocks known as phosphorites have been known since 1959, so, from the radiometric characterization of the Paulista and Igarassu Municipality, in Pernambuco, emanation tests were carried out, aiming to determine the emanation power of radon in samples of uraniferous phosphorite from the Recife Metropolitan Region. Initially, 6 independent samples of phosphorites with activity concentration of 226 Ra> 400 Bq kg -1 were comminuted. Portions of 5g were conditioned in a radon chamber with 500 mL volume for measurements. The linear fit of the model converged after 200 interactions with selection of the best fit by the Chi-Square test, through the Origin® 8.0 program. After analysis of the samples, radon emanation power was estimated in the range of 7% to 15%, with a mean value of 10.8%. The methodology used to determine the emanation parameters in samples of uraniferous phosphorite was adequate, observing an inversely proportional relation between the concentration of the radium-226 and the emanation power

  3. Design, construction and testing of a radon experimental chamber

    International Nuclear Information System (INIS)

    Chavez B, A.; Balcazar G, M.

    1991-10-01

    To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and proved a new automatic exchanger system of passive detectors of radon. The results of the new automatic exchanger system when it leave to flow the radon freely among the container and the automatic exchanger through a plastic membrane of 15 m. are shown. (Author)

  4. Radon: Residential attitudes toward the risk

    International Nuclear Information System (INIS)

    Fort, R.; Hinman, G.; Rosenman, R.; Wandschneider, P.

    1990-01-01

    Veradale, Washington (east of Spokane) is a region of high residential radon concentrations. Three hundred eighty residents of Veradale recently responded to a mail survey designed to elicit (1) their knowledge of and attitudes toward the risks of radon in their homes, (2) the actions they have taken or intend to take to identify and reduce those risks, and (3) policy preferences toward radon. Results reveal that these residents know that they live in an area with high radon levels, that radon causes lung cancer, and that radon will affect their health. However only 11% of respondents have had their homes tested for radon. This especially is puzzling because a large number of respondents claimed that (1) radon was important in home buying decisions, (2) they would test their own homes, (3) they would take action if such tests revealed problems, and (4) their willingness to pay for tests and improvements was well within the current costs of these actions. It remains a mystery why testing is at such a low level. Three other results are of note. First, subsidies for radon tests and home improvements may be having the unintended consequences of unneeded improvements and (potentially) moves without improvements. Second, individuals want radon testing required and results made known during home purchase decisions. Third, at present, weatherization programs that concentrate radon are acceptable to individuals. Of course, the future may hold different results. Administrators of weatherization programs, who are trusted by respondents according to this survey, would do well to institute weatherization programs with reduced radon concentrations in mind

  5. Radon in Austria

    International Nuclear Information System (INIS)

    Friedmann, H.

    2000-01-01

    Several projects in Austria deal with the problem of enhanced radon exposure to the public. The Austrian Radon Project is the largest project within this task, with the aim of investigating the radon concentrations in Austrian homes. Another project concerns mitigation methods. According to the EU directive EURATOM 96/29 it is also necessary to check working places for possibly enhanced radon concentrations. These projects are and will be funded by the government. The federal government of Upper Austria sponsored a project to test the indoor air quality in kindergartens including radon measurements. Within an EU research project, the radon concentrations in Austrian springs and groundwater were systematically listed and analyzed. Additional investigations will focus on methods to improve the radon potential maps from the Austrian Radon Project by including geological and other information. (author)

  6. Epistemic assessment of radon level of offices in Hong Kong

    Science.gov (United States)

    Wong, L. T.; Mui, K. W.; Law, K. Y.; Hui, P. S.

    People spend most of their life working indoors. Human exposure to various air pollutants changed its importance in nature from outdoor to indoor. As some of the pollutant sources basically originate from the building envelope that could not be removed or is costly to mitigate, the remaining questions are: how the indoor air quality (IAQ) is monitored and how the information could be used for the environmental control system to achieve the best air quality delivery. Indoor radon level could be measured with a number of sampling approaches and used to determine the acceptance of an IAQ with respect to certain exposure limits. In determining the acceptable IAQ of a space, this study proposes that the measured indoor radon level must be accompanied with the confidence levels of the assessment. Radon levels in Hong Kong offices were studied by a cross-sectional measurement in 216 typical offices and a year-round longitudinal measurement in one office. The results showed that 96.5% (94.0-99.0% at 95% confidence interval) and 98.6% (97.0% to >99.9% at 95% confidence interval) of the sampled offices would satisfy action radon levels of 150 and 200 Bq m -3, respectively. The same results were then used to quantify the prior knowledge on radon level distributions of an office and the probable errors of the adopted sampling schemes. This study proposes an epistemic approach, with the prior knowledge and a sample test result, to assess the acceptance against an action radon level of an office in Hong Kong. With the certainty of the test results determined for judgmental purposes, it is possible to apply the method to an office for follow-up tests of acceptance.

  7. Comparison of retrospective and contemporary indoor radon measurements in a high-radon area of Serbia

    International Nuclear Information System (INIS)

    Zunic, Z.S.; Yarmoshenko, I.V.; Kelleher, K.; Paridaens, J.; Mc Laughlin, J.P.; Celikovic, I.; Ujic, P.; Onischenko, A.D.; Jovanovic, S.; Demajo, A.; Birovljev, A.; Bochicchio, F.

    2007-01-01

    In Niska Banja, Serbia, which is a high-radon area, a comparison was made between two retrospective radon measuring methods and contemporary radon measurements. The two retrospective methods derive the radon concentrations that occurred in dwellings over longer periods in the past, based on the amount of trapped 210 Po on the surface of glass objects (surface traps, ST) or in the bulk of porous materials (volume traps, VT). Both surface implanted 210 Po in glass objects and contemporary radon in air were measured in 46 rooms, distributed in 32 houses of this radon spa-town, using a dual alpha track detector configuration (CR-39 and LR115) and CR-39 track etched detectors, respectively. In addition to the use of surface trap measurements, in 18 rooms (distributed in 15 houses) VT samples of suitable material were also collected, allowing to compare ST and VT retrospective radon concentration estimates. For each room, contemporary annual radon concentrations (CONT) were measured or estimated using seasonal correction factors. The distribution of the radon concentration in all data sets was found to be close to lognormal (Chi-square test > 0.05). Geometric means (GM) are similar, ranging from 1040 to 1380 Bq m -3 , whereas geometric standard deviations (GSD) for both the retrospective methods are greater than for the CONT method, showing reasonable agreement between VT, ST and CONT measurements. A regression analysis, with respect to the lognormal distribution of each data set, shows that for VT-ST the correlation coefficient r is 0.85, for VT-CONT r is 0.82 and for ST-CONT r is 0.73. Comparison of retrospective and contemporary radon concentrations with regard to supposed long-term indoor radon changes further supports the principal agreement between the retrospective and conventional methods

  8. Measurement of Radon Exhalation Rate in Sand Samples from Gopalpur and Rushikulya Beach Orissa, Eastern India

    Science.gov (United States)

    Mahur, Ajay Kumar; Sharma, Anil; Sonkawade, R. G.; Sengupta, D.; Sharma, A. C.; Prasad, Rajendra

    Natural radioactivity is wide spread in the earth's environment and exists in various geological formations like soils, rocks, water and sand etc. The measurement of activities of naturally occurring radionuclides 226Ra, 232Th and 40K is important for the estimation of radiation risk and has been the subject of interest of research scientists all over the world. Building construction materials and soil beneath the house are the main sources of radon inside the dwellings. Radon exhalation rate from building materials like, cement, sand and concrete etc. is a major source of radiation to the habitants. In the present studies radon exhalation rates in sand samples collected from Gopalpur and Rushikulya beach placer deposit in Orissa are measured by using "Sealed Can technique" with LR-115 type II nuclear track detectors. In Samples from Rushikulya beach show radon activities varying from 389 ± 24 to 997 ± 38 Bq m-3 with an average value of 549 ±28 Bq m-3. Surface exhalation rates in these samples are found to vary from 140 ± 9 to 359 ± 14 mBq m-2 h-1with an average value of 197 ±10 mBq m-2 h-1, whereas, mass exhalation rates vary from 5 ± 0.3 to 14 ± 0.5 mBq kg-1 h-1 with an average value of 8 ± 0.4 mBq kg-1 h-1. Samples from Gopalpur radon activities are found to vary from 371 ± 23 to 800 ± 34 Bq m-3 with an average value of 549 ± 28 Bq m-3. Surface exhalation rates in these samples are found to vary from 133 ± 8 to 288 ± 12 mBq m-2h-1 with an average value of 197 ± 10 mBq m-2 h-1, whereas, mass exhalation rates vary from 5 ± 0.3 to 11 ± 1 mBq kg-1 h-1 with an average value of 8 ± 0.4 mBq kg-1 h-1.

  9. Radon exhalations of rock samples from the Muellenbach uranium test mine

    International Nuclear Information System (INIS)

    Keller, G.; Dudler, R.

    1985-01-01

    Radiation exposure of workers in underground mines with high U/Ra concentration is mostly due to inhalation of the short-lived radioactive decay products of the noble gas radon. Knowledge of the Rn-222 exhalation rates of walls and rocks as well as the contributing influencing parameters is therefore of interest for radiation protection purposes. Measurements showed that in the hours following shortfiring operations, the fresh dirt and the new walls had several times the exhalation rates of older dirt and walls. Measurements of exhalation rates on drill cores can help to assess exhalation for an adequate layout of the mine ventilation system. (orig./PW) [de

  10. Investigations of radon and radon daughters in surficial aquifers of florida

    International Nuclear Information System (INIS)

    1991-05-01

    The principal purpose of the investigation was to test the hypothesis that radon soil flux, considered the principal source of indoor radon contamination, has an underlying relationship to the radon content of associated shallow groundwaters. The working hypothesis was that radon build-up in both soil and shallow groundwater is basically a consequence of the same factor, radon emanation from soil grains and the solid surfaces of the aquifers. Groundwater may be advantageous as an indicator of radon potential. Another object of the project was to investigate temporal and spatial trends of radon daughter products in shallow aquifers. After analyzing all of the radon soil, flux, and groundwater measurements made over the two-year study period, it is clear that while there is no direct relationship between either radon soil concentration or flux and groundwater radon. Measurements in wells where polonium is present at very high concentrations have shown that 210Po is largely unsupported by its radioactive predecessor, and that polonium is considerably more variable, in both space and time than other parameters measured in the same wells, including radon

  11. Experimental study of radon and thoron diffusion through barriers

    Energy Technology Data Exchange (ETDEWEB)

    Durcik, M; Havlik, F [Inst. of Preventive and Clinical Medicine, 83301 Bratislava (Slovakia)

    1996-12-31

    The measurement results of diffusion parameters for radon (radon-222) and thoron (radon-220) through barriers, experimental equipment and theoretical background of diffusion are presented in this paper. The diffusion barriers are used for measuring radon and thoron by passive detectors in order to test the reduction techniques in houses. Six samples (filter paper, rubber, polyethylene, glass laminate, polypropylene) were studied for radon diffusion. The thickness barriers were from 0.012 mm to 2 mm, the diffusion area was 16 cm{sup 2} and the volume V{sub 2} was 30 dm{sup 3}. The diffusion constants D were obtained using given expressions and the data from measurements. The procedures used in experiments are useful for study of diffusion ability of radon and thoron in barriers and determination diffusion parameters from short term measurements. (J.K.). 2 figs., 1 tab., 3 refs.

  12. Experimental study of radon and thoron diffusion through barriers

    International Nuclear Information System (INIS)

    Durcik, M.; Havlik, F.

    1995-01-01

    The measurement results of diffusion parameters for radon (radon-222) and thoron (radon-220) through barriers, experimental equipment and theoretical background of diffusion are presented in this paper. The diffusion barriers are used for measuring radon and thoron by passive detectors in order to test the reduction techniques in houses. Six samples (filter paper, rubber, polyethylene, glass laminate, polypropylene) were studied for radon diffusion. The thickness barriers were from 0.012 mm to 2 mm, the diffusion area was 16 cm 2 and the volume V 2 was 30 dm 3 . The diffusion constants D were obtained using given expressions and the data from measurements. The procedures used in experiments are useful for study of diffusion ability of radon and thoron in barriers and determination diffusion parameters from short term measurements. (J.K.). 2 figs., 1 tab., 3 refs

  13. Find a Radon Test Kit or Measurement and Mitigation Professional

    Science.gov (United States)

    Find a qualified radon service professional to fix or mitigate your home. If you have questions about a radon, you should contact your state radon contact and/or contact one or both of the two privately-run National Radon Proficiency Programs

  14. Radon anomalies: When are they possible to be detected?

    Science.gov (United States)

    Passarelli, Luigi; Woith, Heiko; Seyis, Cemil; Nikkhoo, Mehdi; Donner, Reik

    2017-04-01

    Records of the Radon noble gas in different environments like soil, air, groundwater, rock, caves, and tunnels, typically display cyclic variations including diurnal (S1), semidiurnal (S2) and seasonal components. But there are also cases where theses cycles are absent. Interestingly, radon emission can also be affected by transient processes, which inhibit or enhance the radon carrying process at the surface. This results in transient changes in the radon emission rate, which are superimposed on the low and high frequency cycles. The complexity in the spectral contents of the radon time-series makes any statistical analysis aiming at understanding the physical driving processes a challenging task. In the past decades there have been several attempts to relate changes in radon emission rate with physical triggering processes such as earthquake occurrence. One of the problems in this type of investigation is to objectively detect anomalies in the radon time-series. In the present work, we propose a simple and objective statistical method for detecting changes in the radon emission rate time-series. The method uses non-parametric statistical tests (e.g., Kolmogorov-Smirnov) to compare empirical distributions of radon emission rate by sequentially applying various time window to the time-series. The statistical test indicates whether two empirical distributions of data originate from the same distribution at a desired significance level. We test the algorithm on synthetic data in order to explore the sensitivity of the statistical test to the sample size. We successively apply the test to six radon emission rate recordings from stations located around the Marmara Sea obtained within the MARsite project (MARsite has received funding from the European Union's Seventh Programme for research, technological development and demonstration under grant agreement No 308417). We conclude that the test performs relatively well on identify transient changes in the radon emission

  15. Study of Behavior and detection of radon in environmental samples by scintillation method. Application for radium

    International Nuclear Information System (INIS)

    ZAFIMANJATO, J.L.R.

    2007-01-01

    Radon is considered as the major source of radiological exposure of natural radiations to the population. On an international scale, it represents about the half of exposures of natural radiation sources (UNSCEAR, 1993) Radon gets into human body with inhaled air and sometimes with drinking water. Then, the objective of this work is to know the radon concentrations in water and in indoor atmosphere, and the risk in order to set up a method of monitoring and to identify high radon level areas. A specific method of detection using liquid scintillation with special emphasis on α/β discrimination, the use of solvent extractive and enrichment of radionuclides have been developed for the determination of both 222 Rn and 226 Ra in water. The method is simple, rapid and sensitive. In a pilot project for a monitoring of drinking water in Madagascar, it was shown that the proposed method was suitable for a large scale monitoring and routine analysis. Considerable concentrations of radon were found in water and air samples from Vinaninkarena. Radon concentrations obtained by in situ and in laboratory measurements have been compared to the results of an international intercomparison campaigns organised by the German Society for Liquid Scintillation Spectrometry in 2011. A theoretical study of the behavior of radon is porous material containing radium is detailed in order to describe its exhalation phenomena. An assessment model of the dose due to ingestion and liberation of radon from water is presented and compared with other models especially to the Crawford Brown's model. [fr

  16. Measurement of radon exhalation rate and soil gas radon concentration in areas of southern Punjab (Pakistan)

    International Nuclear Information System (INIS)

    Mujahid, S. A.; Hussain, S.; Ramzan, M.

    2010-01-01

    Plastic track detectors were used to measure the radon concentration and exhalation rate from the soil samples. The samples were collected from areas of southern Punjab (Pakistan). In a laboratory experiment, passive alpha dosemeters were installed inside cylindrical bottles containing the soil samples. The radon concentrations and the radon exhalation rate were found in the ranges of 34±7 to 260±42 Bq m -3 and 38±8 to 288±46 mBq m -2 h -1 , respectively. The on-site measurements of radon in the soil gas were also carried out in these areas using a scintillation alpha counter. The concentration of radon in the soil gas was found in the range of 423±82-3565±438 Bq m -3 . (authors)

  17. Inverse method for determining radon diffusion coefficient and free radon production rate of fragmented uranium ore

    International Nuclear Information System (INIS)

    Ye, Yong-jun; Wang, Li-heng; Ding, De-xin; Zhao, Ya-li; Fan, Nan-bin

    2014-01-01

    The radon diffusion coefficient and the free radon production rate are important parameters for describing radon migration in the fragmented uranium ore. In order to determine the two parameters, the pure diffusion migration equation for radon was firstly established and its analytic solution with the two parameters to be determined was derived. Then, a self manufactured experimental column was used to simulate the pure diffusion of the radon, the improved scintillation cell method was used to measure the pore radon concentrations at different depths of the column loaded with the fragmented uranium ore, and the nonlinear least square algorithm was used to inversely determine the radon diffusion coefficient and the free radon production rate. Finally, the solution with the two inversely determined parameters was used to predict the pore radon concentrations at some depths of the column, and the predicted results were compared with the measured results. The results show that the predicted results are in good agreement with the measured results and the numerical inverse method is applicable to the determination of the radon diffusion coefficient and the free radon production rate for the fragmented uranium ore. - Highlights: • Inverse method for determining two transport parameters of radon is proposed. • A self-made experimental apparatus is used to simulate radon diffusion process. • Sampling volume and position for measuring radon concentration are optimized. • The inverse results of an experimental sample are verified

  18. A Radon Chamber without Radium Source for Detector Calibration and Radon Measurements

    International Nuclear Information System (INIS)

    Al-Azmi, D.; Karunakara, N.

    2008-01-01

    A radon chamber of volume 216 liters was designed and constructed for calibration of radon detectors and radon test measurements. The main feature of this chamber is that the active 226 Ra source, to generate the 222 Rn inside the chamber volume, is not required. Instead, 222 Rn from soil gas is utilized for this purpose. The supply of radon comes from the soil gas. Soil gas is drawn from the soil to fill the chamber with high radon concentration levels (∼ 80 kBq/m3). Desired radon concentration levels can be obtained by drawing the soil gas for different time durations and/or flow rate (author)

  19. The application of artificial neural network in radon disaster model of uranium mining

    International Nuclear Information System (INIS)

    Zhu Yufeng; Zhu Guogen; Zhou Shijian

    2012-01-01

    The structural features, data analysis and learning process of feed-forward neural network (BP ANN) were analyzed at first. Rodon sample from Fuzhou Jinan Uranium Industry Limited Company were used to training the network and make the forecast then, and a forecasting model was established for the radon disaster in uranium mines. The method and effectiveness of BP neural network in predicting radon disaster was discussed. The test of training samples showed that the BP network had gotten fairly satisfied result in predicting mine radon disaster. (authors)

  20. New method and installation for rapid determination of radon diffusion coefficient in various materials.

    Science.gov (United States)

    Tsapalov, Andrey; Gulabyants, Loren; Livshits, Mihail; Kovler, Konstantin

    2014-04-01

    The mathematical apparatus and the experimental installation for the rapid determination of radon diffusion coefficient in various materials are developed. The single test lasts not longer than 18 h and allows testing numerous materials, such as gaseous and liquid media, as well as soil, concrete and radon-proof membranes, in which diffusion coefficient of radon may vary in an extremely wide range, from 1·10(-12) to 5·10(-5) m(2)/s. The uncertainty of radon diffusion coefficient estimation depends on the permeability of the sample and varies from about 5% (for the most permeable materials) to 40% (for less permeable materials, such as radon-proof membranes). Copyright © 2014. Published by Elsevier Ltd.

  1. Measurement of radon exhalation rates in some soil samples collected near the international monument Taj Mahal, Agra

    International Nuclear Information System (INIS)

    Sharma, Jyoti; Kumar, Rupesh; Indolia, R.S.; Swarup, R.; Mahur, A.K.; Singh, Hargyan; Sonkawade, R.G.

    2011-01-01

    Human beings are exposed to ionizing radiation from natural sources due to the occurrence of natural radioactive elements in solids, rocks, sand, soil etc. used as building construction materials and to the internal exposure from radioactive elements through good, water and air. Radon exhalation rate is of prime importance for the estimation of radiation risk from various materials. In the present study soil samples collected near the Tajmahal Agra. Sealed Can Technique was adopted for radon exhalation measurements. All the soil samples collected were grinded, dried and sieved through a 100 mesh sieve. Equal amount of each sieved (100μm grain size) sample (100 gm) was placed at the base of the Cans of 7.5 cm height and 7.0 cm diameter similar to those used in the calibration experiment (Singh et al., 1997). LR-115 type II plastic track detector (2 cm x 2 cm) was fixed on the top inside of the cylindrical Can. Radon exhalation rate varies from 529 mBqm -2 h -1 to 1254 mBqm -2 h -1 . The results will be presented. (author)

  2. Human perception of radon risk and radon mitigation: Some remarks

    International Nuclear Information System (INIS)

    Neznal, M.; Neznal, M.

    2008-01-01

    The Radon program in the Czech Republic has a relatively long and rich history. Procedures, which enable to evaluate the risk of radon penetration from the ground, to protect new buildings, to find existing buildings with elevated indoor radon levels and to realise remedial measures in such buildings, have been developed, published and tested. In some cases, the whole system may fail due to psychological or sociological reasons. Three types of problems (conflicts) will be presented: human behaviour affecting measurement results, conflict between individual and 'all-society' points of view, interpretation of radon risk itself. (authors)

  3. Performance tests for instruments measuring radon activity concentration

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Schmidt, V.

    2009-01-01

    Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection have been tested for the influence of different climatic and radiological factors on the measurement characteristics. It is concluded that all types of instrument, which are commercially available, are suitable for indoor radon measurements. Because of the dependence on climatic conditions, the outdoor use is partly limited.

  4. Evaluation of experiences in long-term radon and radon-daughter measurements

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1982-12-01

    Pacific Northwest Laboratory (PNL) is performing side-by-side measurements of radon and radon daughter concentrations using several instruments and techniques, and is comparing these measurements with side-by-side measurements made by other investigators at other locations. The standard deviation of the differences between the (natural) logarithms of the Terradex Track Etch radon concentrations and the logarithms of the Radon Progency Integrating Sampling Units (RPISU) radon daughter concentrations (S.D.-ln) measured in 50 buildings in Edgemont, South Dakota, was 0.37. Using this S.D.-ln, it can be calculated that if the Track Etch radon daughter concentration is 0.010 WL there should be only a 14% probability that the RPISU average would be greater than 0.015 WL, and only a 3% probability tht the RPISU average would be greater than 0.020 WL. If buildings had been cleared from remedial action when the Track Etch averages were less than 0.10 WL, then about 61% of the buildings would have been cleared from remedial action, and only a few percent of these buildings would have actually had average RPISU concentrations greater than 0.015 WL. The S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements made by ALARA at Grand Junction, the PERM radon measurements and the MOD-225 radon daughter measurements made by Mound Facility at Canonsburg and Middlesex, and the PERM and Track Etch radon measurements made by Mound Facility at Salt Lake City were similar to the S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements at Edgemont

  5. Reducing radon daughter background in alpha continuous air monitors

    International Nuclear Information System (INIS)

    Rodgers, J.C.; McFarland, A.R.

    1991-01-01

    Alpha continuous air monitors are instruments designed to sample aerosols which may contain alpha-emitting radionuclides and, in near-real time, to monitor the sample for alpha emissions. This process is subject to interference from radon decay products. The usual method for overcoming this interference is by signal processing or data processing in such a manner as to accurately subtract a portion of the background from the transuranic count. An innovative alternative approach has been jointly developed in a collaboration between Los Alamos National Laboratory and Texas A ampersand M University. The concept is to attempt to physically remove a portion of the interfering radon daughters from the incoming sample by a diffusion screen before the sample is collected. The results of laboratory tests indicate that a very high removal efficiency for unattached radon progeny can be obtained without excessive loss of efficiency for collection of the contaminant aerosols of concern. 15 refs., 4 figs., 1 tab

  6. Test of the linear-no threshold theory of radiation carcinogenesis for inhaled radon decay products

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1995-01-01

    Data on lung cancer mortality rates vs. average radon concentration in homes for 1,601 U.S. counties are used to test the linear-no threshold theory. The widely recognized problems with ecological studies, as applied to this work, are addressed extensively. With or without corrections for variations in smoking prevalence, there is a strong tendency for lung cancer rates to decrease with increasing radon exposure, in sharp contrast to the increase expected from the theory. The discrepancy in slope is about 20 standard deviations. It is shown that uncertainties in lung cancer rates, radon exposures, and smoking prevalence are not important and that confounding by 54 socioeconomic factors, by geography, and by altitude and climate can explain only a small fraction of the discrepancy. Effects of known radon-smoking prevalence correlations - rural people have higher radon levels and smoke less than urban people, and smokers are exposed to less radon than non-smokers - are calculated and found to be trivial. In spite of extensive efforts, no potential explanation for the discrepancy other than failure of the linear-no threshold theory for carcinogenesis from inhaled radon decay products could be found. (author)

  7. Radon survey in Metropolitan Toronto schools

    International Nuclear Information System (INIS)

    Becker, E.; Moridi, R.

    1992-01-01

    The radon testing survey in Metropolitan Toronto public schools was the most intensive project of its kind ever undertaken in Canadian schools. It also included an extensive public education program on radiation and radon-in-schools. The radon levels at 632 schools were measured using the CAIRS Radon Monitors. Ninety percent of the locations measured were found to have a radon level equal to or less than 2 mWL. Two locations in two different schools were found to have a radon level at or above the Action Level (20 mWL). The remaining results were between the two extremes. Follow-up testing in those schools where more than 10 mWL of radon was found is in progress. (author)

  8. Numerical and analytical assessment of radon diffusion in various media and potential of charcoal as radon detector

    Science.gov (United States)

    Rybalkin, Andrey

    Numerical assessments of radon diffusion together with analytical estimates for short-time and long-time exposure were the first objective of this thesis with the goal to demonstrate how radon propagates in various media. Theoretical predictions were compared to numerical simulations, and obtained values of total radon activities inside each material match quite well with the analytical estimates. These estimates, for activated and nonactivated charcoal, were then used to evaluate the possibility of designing a charcoal system to be used as a radon detector. Another objective was to use nonactivated charcoal samples and measure the level of radon accumulation, and use these data to estimate radon diffusion and adsorption coefficients. The analytical approach was developed to estimate these values. Radon adsorption coefficient in nonactivated charcoal was found to be from 0.2 to 0.4 m3/kg. Radon diffusion coefficient for nonactivated charcoal is in the range of 1.2×10-11 to 5.1×10-10 m2/s in comparison to activated charcoal with adsorption coefficient of 4 m3/kg and diffusion coefficient of 1.43×10-9 m2/s. The third objective was to use GEANT4 numerical code to simulate decay of 238U series and 222Rn in an arbitrary soil sample. Based on that model, the goal was to provide a guideline for merging GEANT4 radioactive decay modeling with the diffusion of radon in a soil sample. It is known that radon can be used as an earthquake predictor by measuring its concentration in groundwater, or if possible, along the faults. Numerical simulations of radon migration by diffusion only were made to estimate how fast and how far radon can move along the fault strands. Among the known cases of successful correlations between radon concentration anomalies and earthquake are the 1966 Tashkent and 1976 Songpan-Pingwu earthquakes. Thus, an idea of radon monitoring along the Wasatch Fault, using system of activated/nonactivated charcoals together with solid state radon detectors is

  9. Radon risk communication research: Practical lessons

    International Nuclear Information System (INIS)

    Fisher, A.; Johnson, F.R.

    1990-01-01

    Those responsible for state and local radon programs often express frustration about the small share of homes that have been tested for radon, and the small share of those with high readings that have been mitigated. There are now a number of completed studies that have examined how well alternative ways of communicating about radon risk have accomplished the goals of motivating appropriate testing and mitigation. This paper summarizes the research results that are most crucial for planning and implementing effective radon risk communication programs. We identify six reasons why people do not respond to radon as a serious threat and provide some remedies suggested by radon studies

  10. Radiological risk assessment of environmental radon

    Energy Technology Data Exchange (ETDEWEB)

    Khalid, Norafatin; Majid, Amran Ab; Yahaya, Redzuwan; Yasir, Muhammad Samudi [Nuclear Science Programme, School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia)

    2013-11-27

    Measurements of radon gas ({sup 222}Rn) in the environmental are important to assess indoor air quality and to study the potential risk to human health. Generally known that exposure to radon is considered the second leading cause of lung cancer after smoking. The environmental radon concentration depends on the {sup 226}Ra concentration, indoor atmosphere, cracking on rocks and building materials. This study was carried out to determine the indoor radon concentration from selected samples of tin tailings (amang) and building materials in an airtight sealed homemade radon chamber. The radiological risk assessment for radon gas was also calculated based on the annual exposure dose, effective dose equivalent, radon exhalation rates and fatal cancer risk. The continuous radon monitor Sun Nuclear model 1029 was used to measure the radon concentration emanates from selected samples for 96 hours. Five types of tin tailings collected from Kampar, Perak and four samples of building materials commonly used in Malaysia dwellings or building constructions were analysed for radon concentration. The indoor radon concentration determined in ilmenite, monazite, struverite, xenotime and zircon samples varies from 219.6 ± 76.8 Bq m{sup −3} to 571.1 ± 251.4 Bq m{sup −3}, 101.0 ± 41.0 Bq m{sup −3} to 245.3 ± 100.2 Bq m{sup −3}, 53.1 ± 7.5 Bq m{sup −3} to 181.8 ± 9.7 Bq m{sup −3}, 256.1 ± 59.3 Bq m{sup −3} to 652.2 ± 222.2 Bq m{sup −3} and 164.5 ± 75.9 Bq m{sup −3} to 653.3 ± 240.0 Bq m{sup −3}, respectively. Whereas, in the building materials, the radon concentration from cement brick, red-clay brick, gravel aggregate and cement showed 396.3 ± 194.3 Bq m{sup −3}, 192.1 ± 75.4 Bq m{sup −3}, 176.1 ± 85.9 Bq m{sup −3} and 28.4 ± 5.7 Bq m{sup −3}, respectively. The radon concentration in tin tailings and building materials were found to be much higher in xenotime and cement brick samples than others. All samples in tin tailings were exceeded the

  11. Design, construction and testing of a radon experimental chamber; Diseno, construccion y pruebas de una camara experimental de radon

    Energy Technology Data Exchange (ETDEWEB)

    Chavez B, A; Balcazar G, M

    1991-10-15

    To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and proved a new automatic exchanger system of passive detectors of radon. The results of the new automatic exchanger system when it leave to flow the radon freely among the container and the automatic exchanger through a plastic membrane of 15 m. are shown. (Author)

  12. New method and installation for rapid determination of radon diffusion coefficient in various materials

    International Nuclear Information System (INIS)

    Tsapalov, Andrey; Gulabyants, Loren; Livshits, Mihail; Kovler, Konstantin

    2014-01-01

    The mathematical apparatus and the experimental installation for the rapid determination of radon diffusion coefficient in various materials are developed. The single test lasts not longer than 18 h and allows testing numerous materials, such as gaseous and liquid media, as well as soil, concrete and radon-proof membranes, in which diffusion coefficient of radon may vary in an extremely wide range, from 1·10 −12 to 5·10 −5 m 2 /s. The uncertainty of radon diffusion coefficient estimation depends on the permeability of the sample and varies from about 5% (for the most permeable materials) to 40% (for less permeable materials, such as radon-proof membranes). - Highlights: • The new method and installation for determination of radon diffusion coefficient D are developed. • The measured D-values vary in an extremely wide range, from 5×10 -5 to 1×10 -12 m 2 /s. • The materials include water, air, soil, building materials and radon-proof membranes. • The duration of the single test does not exceed 18 hours. • The measurement uncertainty varies from 5% (in permeable materials) to 40% (in radon gas barriers)

  13. Measuring radon in the workplace

    International Nuclear Information System (INIS)

    Boyd, M.

    1990-01-01

    The Environmental Protection Agency (EPA) has issued guidance for testing for radon in homes and interim guidance for testing in schools. Information on testing for radon in the workplace is the next initiative and this paper describes the current status of this effort. The results of measurements made in several buildings in the Washington, DC area are discussed. In this paper a discussion of preliminary guidance on radon survey design that has been offered to Federal agencies is presented

  14. Laboratory measurements of radon diffusion through multilayered cover systems for uranium tailings

    International Nuclear Information System (INIS)

    Nielson, K.K.; Rogers, V.C.; Rich, D.C.; Nederhand, F.A.; Sandquist, G.M.; Jensen, C.M.

    1981-12-01

    Laboratory measurements of radon fluxes and radon concentration profiles were conducted to characterize the effectiveness of multilayer cover systems for uranium tailings. The cover systems utilized soil and clay materials from proposed disposal sites for the Vitro, Durango, Shiprock, Grand Junction and Riverton tailings piles. Measured radon fluxes were in reasonable agreement with values predicted by multilayer diffusion theory. Results obtained by using air-filled porosities in the diffusion calculations were similar to those obtained by using total porosities. Measured diffusion coefficients were a better basis for predicting radon fluxes than were correlations of diffusion coefficient with moisture or with air porosity. Radon concentration profiles were also fitted by equations for multilayer diffusion in the air-filled space. Layer-order effects in the multilayer cover systems were examined and estimated to amount to 10 to 20 percent for the systems tested. Quality control measurements in support of the multilayer diffusion tests indicated that moisture absorption was not a significant problem in radon flux sampling with charcoal canisters, but that the geometry of the sampler was critical. The geometric design of flux-can samplers was also shown to be important. Enhanced radon diffusion along the walls of the test columns was examined and was found to be insignificant except when the columns had been physically disturbed. Additional moisture injected into two test columns decreased the radon flux, as expected, but appeared to migrate into surrounding materials or to be lost by evaporation. Control of moisture content and compaction in the test columns appeared to be the critical item affecting the accuracies of the experiments

  15. Measurements of radon and chemical elements: Popocatepetl volcano; Mediciones de radon y elementos quimicos: Volcan Popocatepetl

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Segovia, N.; Lopez, B.; Reyes, A.V. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Armienta, M.A.; Valdes, C.; Mena, M. [IGFUNAM, Ciudad Universitaria, 04510 Mexico D.F. (Mexico); Seidel, J.L.; Monnin, M. [UMR 5569 CNRS Hydrosciences, Montpellier (France)

    2002-07-01

    The Popocatepetl volcano is a higher risk volcano located at 60 Km from Mexico City. Radon measurements on soil in two fixed seasons located in the north slope of volcano were carried out. Moreover the radon content, major chemical elements and tracks in water samples of three springs was studied. The radon of soil was determined with solid detectors of nuclear tracks (DSTN). The radon in subterranean water was evaluated through the liquid scintillation method and it was corroborated with an Alpha Guard equipment. The major chemical elements were determined with conventional chemical methods and the track elements were measured using an Icp-Ms equipment. The radon on soil levels were lower, indicating a moderate diffusion of the gas across the slope of the volcano. The radon in subterranean water shown few changes in relation with the active scene of the volcano. The major chemical elements and tracks showed a stable behavior during the sampling period. (Author)

  16. Paloma-radon: atmospheric radon 222 as a geochemical probe for water in the martian subsoil

    International Nuclear Information System (INIS)

    Sabroux, J.Ch.; Michielsen, N.; Voisin, V.

    2003-01-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon 222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO 2 ). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option. In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a set of alpha detectors connected to an electronic spectrometer, a

  17. Paloma-radon: atmospheric radon 222 as a geochemical probe for water in the martian subsoil

    Energy Technology Data Exchange (ETDEWEB)

    Sabroux, J.Ch.; Michielsen, N.; Voisin, V

    2003-07-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon 222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO{sub 2}). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option. In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a set of alpha detectors connected to an electronic spectrometer

  18. Radon chamber for soil gas detectors

    International Nuclear Information System (INIS)

    Andersson, P.

    1987-01-01

    Swedish Geological Co (SGAB) has designed and constructed a chamber for the calibration of detectors and instruments intended for the measurement of radon-222 in soil gas. In the chamber radon detectors may be exposed in a model environment which simulates ground conditions with respect to radon concentration, temperature and humidity. Also included in the research project is the development of methods for calibration procedures, together with test measurements. In general, these measurements indicate that the radon detectors tested are sufficiently accurate and reliable for radon measurements in Swedish soils if they are calibrated in an environment which simulates ground conditions. (orig./HP)

  19. Radon prevention in new construction in Finland: A nationwide sample survey in 2009

    International Nuclear Information System (INIS)

    Arvela, H.; Holmgren, O.; Reisbacka, H.

    2012-01-01

    The building code for radon prevention and the associated practical guidelines were revised in Finland in 2003-2004. Thereafter, preventive measures have become more common and effective and indoor radon concentrations have been markedly reduced. In this study, the indoor radon concentration was measured in 1500 new low-rise residential houses. The houses were randomly selected and represented 7 % of the houses that received building permission in 2006. The average radon concentration of all the houses measured, which were completed in 2006-2008, was 95 Bq m -3 , the median being 58 Bq m -3 . The average was 33 % lower than in houses completed in 2000-2005. The decrease was 47 % in provinces with the highest indoor radon concentration and 26 % elsewhere in the country. In houses with a slab-on-ground foundation that had both passive radon piping and sealing measures carried out using a strip of bitumen felt in the joint between the foundation wall and floor slab, the radon concentration was on average reduced by 57 % compared with houses with no preventive measures. Preventive measures were taken nationwide in 54 % of detached houses and in provinces with the highest radon concentration in 92 % of houses. (authors)

  20. Development of a radon chamber and measurement of the radon solubility in tissues; Entwicklung einer Radonkammer und Messung der Radonloeslichkeit in Gewebe

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Andreas

    2015-04-22

    Every year thousands of patients with inflammatory diseases of the musculoskeletal system undergo radon therapy, but the molecular mechanism and the risk of this therapy are not understood. To study the effects of radon exposure in vitro and in vivo we constructed a radon exposure chamber in the framework of the GREWIS project. With this device we are able to expose samples under controlled and reproducible conditions including the radon galleries in Austria and Germany. Adjustable parameters are radon activity-concentration, temperature, humidity and exposure time. These parameters are permanently monitored and controlled. During experiments with cell cultures it is also possible to adjust the CO{sub 2}-concentration. In addition, experiments with mice can be performed with this setup. To measure the radon kinetics in different types of tissue we exposed tissue samples like fat or muscle and mice in the radonchamber. Afterwards we measured the -spectra of the short living radon decay products lead-214 and bismuth-214 in the exposed samples with a HPGe-Detector. We recorded the spectra at different time points after exposure and calculated the initial amount of radon at the end of the exposure period in the sample and investigated the diffusion of the radon out of it. We compared the results from different types of tissue but also activated coal. In an activated coal sample the radon is bound to it via Van-der-Waals-force and the decay spectra are governed by the life time of the bound radon (3,8 days). In contrast in the biological samples the primary radon diffuses out of the samples in less than 20 minutes and the spectra follow the kinetics of the decay of the daughter products. These measurements where performed for the first time under therapy conditions like in radon galleries and also with higher radon concentration. In our experiments we could see an enhanced accumulation of radon and its decay products in fatty tissue compared to muscle tissue. Also in

  1. Discussion on the source of radon in uranium exploration method using radon-released thermal effect in minerals

    International Nuclear Information System (INIS)

    Su Shoutian.

    1985-01-01

    This paper considers the problem of the source of radon in uranium exploration method using radon-released thermal effect. In minerals by means of scintillation emanometry, we have carried out the measurement on radon content in minerals at various temperature in barren and ore-bearing granites of the granite-type uranium deposit No. 752, and inclusion decrepitation method has also been used to determine the temperature of decrepitation and its relative frequency. It was found from experiments that heated samples may release most of radon prior to inclusion decrepitation, radon released from thermal effect was, on the contrary, very little at temperature intervals of inclusion decrepitation on a large scale basis. When inclusions were ground after radon releasing, it would still release from inclusions after reheating. The radon content calculated from uranium content in inclusions is lower than the sensitivity of the determination method, so it is too difficult to be determined, indicating that the radon content released is not related to inclusions. Samples were determined by uranium chemical analysis and radium radiochemical analysis and it is obvious to note that the radon content released from thermal effect in minerals is positively correlated to the uranium and radium content. Various kinds of experiments suggest that radon is not derived from inclusions but from the whole mineral

  2. Unattached radon daughter atoms and radon daughter equilibrium ratios in uranium mines. Final report

    International Nuclear Information System (INIS)

    Holaday, D.A.

    1972-01-01

    Uranium mines in Colorado and New Mexico were surveyed for airborne concentrations of radon (10043922) and radon daughters. A procedure for measuring individual daughters and the fraction of each existing as free atoms was developed and used for field monitoring. Samples were taken in working areas and particle counts were made. The data was analyzed to determine the ratio of radon to radon daughters as well as the ratios among the radon daughters. The author concludes that since the radon to working level ratios have not changed much in 20 years, using the ratio as the basis for estimating relative biological hazard is just as uncertain now as then. The large number of daughters present as free atoms indicate that the lung radiation doses calculated using any of the lung models need reexamination

  3. Radon as a hydrological indicator

    Energy Technology Data Exchange (ETDEWEB)

    Komae, Takami [National Research Inst. of Agricultural Engineering, Tsukuba, Ibaraki (Japan)

    1997-02-01

    The radon concentration in water is measured by a liquid scintillation method. After the radioactive equilibrium between radon and the daughter nuclides was attained, the radon concentration was determined by the liquid scintillation analyzer. {alpha}-ray from radon, then two {beta}- and two {alpha}-ray from the daughter nuclei group were released, so that 500% of the apparent counting efficiency was obtained. The detector limit is about 0.03 Bq/l, the low value, which corresponds to about 5.4x10{sup -15} ppm. By determining the radon concentration in groundwater, behavior of radon in hydrological process, the groundwater exchange caused by pumping and exchange between river water and groundwater were investigated. The water circulation analysis by means of radon indicator in the environment was shown. By using the large difference of radon concentration between in river water and in groundwater, arrival of injected water to the sampling point of groundwater was detected. (S.Y.)

  4. Development of Radon-222 as Natural Tracer for Monitoring the Remediation of NAPL in the Subsurface

    International Nuclear Information System (INIS)

    Davis, Brian M.; Semprini, Lewis; Istok, Jonathan

    2003-01-01

    Naturally occurring 222-radon in ground water can potentially be used as an in situ partitioning tracer to characterize dense nonaqueous phase liquid (DNAPL) saturations. The static method involves comparing radon concentrations in water samples from DNAPL-contaminated and non-contaminated portions of an aquifer. During a push-pull test, a known volume of test solution (radon-free water containing a conservation tracer) is first injected (''pushed'') into a well; flow is then reversed and the test solution/groundwater mixture is extracted (''pulled'') from the same well. In the presence of NAPL radon transport is retarded relative to the conservative tracer. Assuming linear equilibrium partitioning, retardation factors for radon can be used to estimate NAPL saturations.The utility of this methodology was evaluated in laboratory and field settings

  5. Communicating the risk from radon

    International Nuclear Information System (INIS)

    Fisher, A.; McClelland, G.H.; Schulze, W.D.; Doyle, J.K.

    1991-01-01

    A prominent television station developed a special series of newscasts and public service announcements about radon. This was combined with their advertising of the availability of reduced-price radon test kits in a local supermarket chain. The large number of test kits sold was a success from a marketing perspective, but not from a public health perspective - especially because of the very small share of high readings that were mitigated. In contrast, a study of housing sales showed a much higher testing rate and corresponding mitigation when risk communication accompanied the housing transaction, rather than being directed toward the general public. This paper examined the relative effectiveness of these alternative approaches to radon risk communication, emphasizing the implications for developing and implementing radon programs

  6. Radon

    International Nuclear Information System (INIS)

    Holmen, R.W.

    1987-01-01

    The discovery that radon enters into residential and commercial structures and produces adverse health consequences to occupants thereof has raised issues for the real estate profession in connection with transactions involving affected structures. The legal responsibilities of real estate professionals in relation to such structures have not yet been clearly defined. Moreover, consistent and reliable testing methods and results, clear identification of circumstances where testing is necessary, and consensus as to health risks suggested by various radon levels have yet to be achieved. When these legal and technical questions are clarified, real estate buyer and sellers as well as agents and brokers will be greatly benefited

  7. MEASUREMENT OF RADON EXHALATION RATE, RADIUM ACTIVITY AND ANNUAL EFFECTIVE DOSE FROM BRICKS AND CEMENT SAMPLES COLLECTED FROM DERA ISMAIL KHAN

    OpenAIRE

    Nisar Ahmad; Mohamad Suhaimi Jaafar; Sohail Aziz Khan; Tabassum Nasir; Sajjad Ahmad; Muhammad Rahim

    2014-01-01

    Radon concentration, exhalation rate, radium activity and annual effective dose have been measured from baked and unbaked bricks and cement samples commonly used as construction material in the dwellings of Dera Ismail Khan City, Pakistan. CR-39 based NRPB radon dosimeters and RAD7 have been used as passive and active devises. The values of radon concentration for baked, unbaked bricks and cements obtained from passive and active techniques were found in good agreement. Average values of rado...

  8. Instruments to measure radon activity concentration or exposure to radon. Interlaboratory comparison 2011

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2011-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by BfS. A radon measuring service is recognized by the competent authority if it proves its organizational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the website www.bfs.de/de/ion/radon/fachinfomessung/vergleichspruefungen.html and from the European Information System on Proficiency Testing Schemes (eptis) available in the internet. (orig.)

  9. Orphan radon daughters at Denver Radium site

    International Nuclear Information System (INIS)

    Holub, R.F.; Droullard, R.F.; Davis, T.H.

    1992-01-01

    During 18 mo of sampling airborne radioactively at a National Priority List (open-quotes Superfundclose quotes) site in metroPOlitan Denver, Bureau of mines personnel discovered radon daughters that are not supported by the parent radon gas. We refer to them as open-quotes orphanclose quotes daughters because the parent, radon, is not present in sufficient concentration to support the measured daughter products. Measurements of the open-quotes orphanclose quotes daughters were made continuously, using the Bureau-developed radon and working-level (radon-daughter) monitors. The data showed high equilibrium ratios, ranging from 0.7 to 3.5, for long periods of time. Repeated, high-volume, 15-min grab samples were made, using the modified Tsivoglou method, to measure radon daughters, to which thoron daughters contributed 26 ± 12%. On average 28 ± 6% of the particulate activity was contributed by thoron daughters. Most samples were mixtures in which the 218 Po concentration was lower than that of 214 Pb and 214 Bi, in agreement with the high-equilibrium factors obtained from the continuous sampling data. In view of the short half-life of radon progeny, we conclude that the source of the orphan daughters is not far from the Superfund sites. The mechanism of this phenomenon is not understood at this time, but we will discuss its possible significance in evaluating population doses

  10. Reconstruction of national distribution of indoor radon concentration in Russia using results of regional indoor radon measurement programs

    International Nuclear Information System (INIS)

    Yarmoshenko, I.; Malinovsky, G.; Vasilyev, A.; Zhukovsky, M.

    2015-01-01

    The aim of the paper is a reconstruction of the national distribution and estimation of the arithmetic average indoor radon concentration in Russia using the data of official annual 4-DOZ reports. Annual 4-DOZ reports summarize results of radiation measurements in 83 regions of Russian Federation. Information on more than 400 000 indoor radon measurements includes the average indoor radon isotopes equilibrium equivalent concentration (EEC) and number of measurements by regions and by three main types of houses: wooden, one-storey non-wooden, and multi-storey non-wooden houses. To reconstruct the national distribution, all-Russian model sample was generated by integration of sub-samples created using the results of each annual regional program of indoor radon measurements in each type of buildings. According to indoor radon concentration distribution reconstruction, all-Russian average indoor radon concentration is 48 Bq/m"3. Average indoor radon concentration by region ranges from 12 to 207 Bq/m"3. The 95-th percentile of the distribution is reached at indoor radon concentration 160 Bq/m"3. - Highlights: • Reconstruction of indoor radon concentration distribution in Russia was carried out. • Data of official annual 4-DOZ reports were used. • All-Russian average indoor radon concentration is 48 Bq/m"3. • The 95-th percentile is 160 Bq/m"3.

  11. ERRICCA radon model intercomparison exercise

    DEFF Research Database (Denmark)

    Andersen, C.E.; Albarracín, D.; Csige, I.

    1999-01-01

    -state diffusive radon profiles in dry and wet soils, (2) steady-state entry of soil gas and radon into a house, (3) time-dependent radon exhalation from abuilding-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive......, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommendedthat additional exercises are carried out....

  12. Radon exposure and lung cancer

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.; Faj, Z.; Radolic, V.; Suveljak, B.

    2003-01-01

    Although studies of radon exposure have established that Rn decay products are a cause of lung cancer among miners, the lung cancer risk to the general population from indoor radon remains unclear and controversial. Our epidemiological investigation of indoor radon influence on lung cancer incidence was carried out for 201 patients from the Osijek town. Ecological method was applied by using the town map with square fields of 1 km 2 and the town was divided into 24 fields. Multiple regression study for the lung cancer rate on field, average indoor radon exposure and smoking showed a positive linear double regression for the mentioned variables. Case-control study showed that patients, diseased of lung cancer, dwelt in homes with significantly higher radon concentrations, by comparison to the average indoor radon level of control sample. (author)

  13. Soil gas and radon entry into a simple test structure: Comparison of experimental and modelling results

    DEFF Research Database (Denmark)

    Andersen, C.E.; Søgaard-Hansen, J.; Majborn, B.

    1994-01-01

    A radon test structure has been established at a field site at Riso National Laboratory. Measurements have been made of soil gas entry rates, pressure couplings and radon depletion. The experimental results have been compared with results obtained from measured soil parameters and a two......-dimensional steady-state numerical model of Darcy flow and combined diffusive and advective transport of radon. For most probe locations, the calculated values of the pressure couplings and the radon depletion agree well with the measured values, thus verifying important elements of the Darcy flow approximation......, and the ability of the model to treat combined diffusive and advective transport of radon. However, the model gives an underestimation of the soil gas entry rate. Even if it is assumed that the soil has a permeability equal to the highest of the measured values, the model underestimates the soil gas entry rate...

  14. Instrumentation for a radon research house

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Revzan, K.L.; Robb, A.W.

    1981-07-01

    A highly automated monitoring and control system for studying radon and radon-daughter behavior in residences has been designed and built. The system has been installed in a research house, a test space contained in a two-story wood-framed building, which allows us to conduct controlled studies of (1) pollutant transport within and between rooms, (2) the dynamics of radon daughter behavior, and (3) techniques for controlling radon and radon daughters. The system's instrumentation is capable of measuring air-exchange rate, four-point radon concentration, individual radon daughter concentrations, indoor temerature and humidity, and outdoor weather parameters (temperature, humidity, modules, wind speed, and wind direction). It is also equipped with modules that control the injection of radon and tracer gas into the test space, the operation of the forced-air furnace, the mechanical ventilation system, and the mixing fans located in each room. A microcomputer controls the experiments and records the data on magnetic tape and on a printing terminal. The data on tape is transferred to a larger computer system for reduction and analysis. In this paper we describe the essential design and function of the instrumentation system, as a whole, singling out those components that measure ventilation rate, radon concentration, and radon daughter concentrations

  15. Paloma-radon: Atmospheric radon-222 as a geochemical probe for water in the Martian subsoil.

    Science.gov (United States)

    Sabroux, J.-C.; Michielsen, N.; Voisin, V.; Ferry, C.; Richon, P.; Pineau, J.-F.; Le Roulley, J.-C.; Chassefière, E.

    2003-04-01

    Radon exhalation from a porous soil is known to depend strongly on the soil moisture content: a minute amount of water, or water ice, in the pore space increases dramatically the possibility for radon to migrate far from its parent mineral. We propose to take advantage of this characteristic by using atmospheric radon-222 as a geochemical probe for water in the Martian soil, at least one order of magnitude deeper than the current Mars Odyssey neutron data. Strong thermal inversions during the Martian night will accumulate radon in the lowest atmospheric boundary layer, up to measurable levels despite the comparatively high environmental (cosmic and solar) background radiation and the assumed low uranium content of the upper crust of the planet. Preliminary studies and development of an instrument for the measurement of the Martian atmospheric alpha radioactivity is part of the CNES-supported PALOMA experiment. Two test benches have been implemented, one of them allowing differential measurements of the diffusion of radon in the Martian soil simulant NASA JSC Mars-1, under relevant temperatures and pressures. The other, a 1 m^3 radon-dedicated test bench, aims to characterize the instrument that will measure radon in the Mars environment (7 mb CO_2). Tests on several nuclear radiation detectors show that semiconductor alpha-particle detectors (PIPS) are the best option (already on board the Mars Pathfinder Rover and other platforms). In addition, the detection volume is left open in order to capitalize upon the long (ca. 4 m) alpha track at this low pressure. A stationary diffusion model was developed in order to assess the radon flux at the Mars soil surface. Diffusion of gas in Martian soil is governed by Knudsen diffusion. The radon Knudsen diffusion coefficient was estimated, depending on the soil moisture and relevant structural properties, leading to a radon diffusion length of the order of 20 m. The landed platform PALOMA-Radon instrument will consist of a

  16. Radon emanation characteristics of uranium mill tailings

    International Nuclear Information System (INIS)

    Nielson, K.K.; Freeman, H.D.; Hartley, J.N.; Mauch, M.L.; Rogers, V.C.

    1982-01-01

    Radon emanation from uranium mill tailings was examined with respect to the mechanisms of emanation and the physical properties of the tailings which affect emanation. Radon emanation coefficients were measured at ambient moisture on 135 samples from the 1981 field test site at the Grand Junction tailings pile. These coefficients showed a similar trend with moisture to those observed previously with uranium ores, and averaged 0.10 + or - 0.02 at dryness and 0.38 + or - 0.04 for all samples having greater than five weight-percent moisture. Small differences were noted between the maximum values of the coefficients for the sand and slime fractions of the tailings. Separate measurements on tailings from the Vitro tailings pile exhibited much lower emanation coefficients for moist samples, and similar coefficients for dry samples. Alternative emanation measurement techniques were examined and procedures are recommended for use in future work

  17. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  18. Open charcoal chamber method for mass measurements of radon exhalation rate from soil surface

    International Nuclear Information System (INIS)

    Tsapalov, Andrey; Kovler, Konstantin; Miklyaev, Peter

    2016-01-01

    Radon exhalation rate from the soil surface can serve as an important criterion in the evaluation of radon hazard of the land. Recently published international standard ISO 11665-7 (2012) is based on the accumulation of radon gas in a closed container. At the same time since 1998 in Russia, as a part of engineering and environmental studies for the construction, radon flux measurements are made using an open charcoal chamber for a sampling duration of 3–5 h. This method has a well-defined metrological justification and was tested in both favorable and unfavorable conditions. The article describes the characteristics of the method, as well as the means of sampling and measurement of the activity of radon absorbed. The results of the metrological study suggest that regardless of the sampling conditions (weather, the mechanism and rate of radon transport in the soil, soil properties and conditions), uncertainty of method does not exceed 20%, while the combined standard uncertainty of radon exhalation rate measured from the soil surface does not exceed 30%. The results of the daily measurements of radon exhalation rate from the soil surface at the experimental site during one year are reported. - Highlights: • Radon exhalation rate from the soil surface area of 32 cm"2 can be measured at level of 10 mBq/(m"2s) at the uncertainty ≤30%. • The method has a metrological justification. • No need to consider climate conditions, soil properties and conditions, mechanism and rate of radon transport in the soil.

  19. Swiss radon programme 'RAPROS'

    International Nuclear Information System (INIS)

    Zeller, W.

    1992-03-01

    The results of the five-year radon research program RAPROS presented in this report, allow for scientifically valid statements on the origin of elevated levels of indoor radon in Switzerland. These results form a basis for recommendations and for actions to be taken. Indoor radon concentrations have been measured in more than 4000 living-rooms and 2000 basements; a sampling density of about 0.2% of the Swiss housing stock. According to these measurements radon leads to an estimated average annual effective dose of 2 milli-Sievert, although in some regions the annual dose may be much higher. Extrapolation of the existing data shows that in about 10'000 Swiss houses radon may exceed 1000 Bq/m 3 . For these houses remedial actions are recommended. There seems to be no radon problem in the large cities in the Swiss Plateau. High indoor radon concentrations in Switzerland are due to the soil beneath the buildings. Data from the study indicated that the most important soil characteristic influencing indoor radon concentrations was its gas permeability. Because natural ventilation in a heated house creates a slight underpressure in the lower levels with respect to surrounding soils, radon is driven from the soil into the building. Weatherization of the houses to reduce energy consumption had in most cases no effect on the indoor radon concentrations. Radon from tap water or from building materials does not contribute significantly to indoor radon levels in Switzerland. The high levels in the Jura Mountains are thought to be associated with karstic limestone bedrock. Several houses within Switzerland have now been modified to reduce radon levels. The most successful mitigation technique combined forced-air ventilation with tightening of the basement to decrease or prevent air infiltration from the soil. (author) figs., tabs., refs

  20. Cost and effectiveness of radon barrier systems

    International Nuclear Information System (INIS)

    Baker, E.G.; Freeman, H.D.; Hartley, J.N.; Gee, G.W.

    1982-12-01

    Earthen, asphalt, and multilayer radon barrier systems can all provide reduction in the amount of radon gas released from uranium mill tailings. Pacific Northwest Laboratory field tested all three types of covers at Grand Junction, Colorado during the summer of 1981. All nine individual radon barrier systems tested currently meet the EPA standard for radon flux of 20 pCi m - 2 s - 1 . The cost of the asphalt and 3m earthen covers were about the same at the field test. Multilayer covers were significantly more costly. Cost estimates for three high priority western sites indicate 3m of earthen cover is the least costly radon barrier when earthen material is available at or near the disposal site. If earthen material must be imported more than 8 to 10 km asphalt and possibly multilayer radon barriers can be cost effective

  1. Radon activities in natural gases

    International Nuclear Information System (INIS)

    Sajo, B.L.; Palfalvi, J.

    1995-01-01

    Radon activities have been measured in gas samples used for residential heading, in Venezuela and in Hungary. Gas bottles were selected randomly in different regions, and radon activities were monitored with ionization clambers and solid stoke track detections. Radon concentrations in household natural gas are presented for regions in Venezuela and in Budapest, Hungary. The latter was found to be in the range of 88-135 Bq/m 3 . (R.P.)

  2. Mapping corrections for radon indoor data suggested by simulated data distributions

    International Nuclear Information System (INIS)

    Majerus, J.; Kies, A.; Tondeur, F.

    2004-01-01

    Indoor radon measurements may be considered as a stochastic function of spatial or spatio-temporal coordinates. This is characterized by a combination of deterministic and stochastic factors, including an important local 'noise' due to special indoor conditions. Radon mapping always consists in trying to smooth out the noise and possible outliers, to identify risk zones of high radon concentrations. To explore the spatial variation of radon we used indoor concentration data, obtained in Luxembourg and Belgium. These indoor radon databases have medium sampling density of 1 to 2 data per km 2 , respectively 0,3 data per km 2 . Furthermore we tried to investigate the relationship between geologic conditions and indoor radon concentrations. For indoor radon data, the best data sampling is restricted to all given house locations, thus we first investigated the ability to recover geological information with respect to the restricted indoor sampling distribution. To do so, we used simulated radon data with different sampling density and local clustering, generated by assuming specified average values depending on the coordinates, broadened by a typical log-normal noise and outliers of varying magnitude. Data clustering inside of villages and under-representation of the far field data locations leads to the well-known bull-eyes effects in mapping. Because the underlying deterministic structure of the simulated data is known, these data can be used to test different pre-treatments to apply before running a given gridding method. Adequate corrections for the non-uniform sampling distribution of radon indoor data can thus be explored. Furthermore, it is shown how simulated data can help to find good smoothing criteria. With smoothing needed, it may be difficult to find a good compromise between showing only significant features and showing more details at the risk of pointing out irrelevant details or even artifacts. Simulated data proved to be very useful in this context. In

  3. The householders' guide to radon

    International Nuclear Information System (INIS)

    1988-06-01

    This guide is a follow-up to the leaflet Radon in Houses which was issued previously by the Department of the Environment. It is intended for people who live in areas with high levels of radon. It is written particularly for householders whose homes have already been tested and found to have an appreciable level of radon. It explains what radon is, how it gets into houses and what the effects on health may be. It also outlines some of the ways of reducing the level of radon and gives guidance both on how to get the work done and likely costs. (author)

  4. Assessment of radiation exposure to miners due to radon and radon daughters

    International Nuclear Information System (INIS)

    Przyborowski, S.

    1979-01-01

    An overview is given of the basic considerations regarding the establishment of lung limits for miners exposed to radon and radon daughters. Problems associated with the practical conduct of radiation protection monitoring are also dealt with, for example, the implications of temporal and local variations in activity levels to the mode of sampling and the interpretation of results. (author)

  5. Calibration of environmental monitors operating on time integrating principles for radon/thoron decay products

    International Nuclear Information System (INIS)

    Bigu, J.; Grenier, M.

    1982-03-01

    An environmental radiation monitor for radon decay products has been tested under laboratory controlled conditions. The instrument is of a quasi-time-integrating type and was tested in conjunction with a radon 'box' calibration facility. It has been found that the instrument appreciably underestimates the radon daughter Working Level (WL). This is attributed to plate-out of decay products in the monitor sampling head. The difference between monitor reading and the WL by grab-sampling was higher for low aerosol concentrations. Plate-out on the instrument detector and sampling head, and contamination effects have been observed for the thoron case. There is partial agreement between experimental results and theoretical expectation. The monitor is slow to react to sudden changes in radiation level. The instrument should prove quite useful in the routine monitoring of surface and underground environments provided some suggested changes in the instrument are introduced

  6. MODEL RADIOACTIVE RADON DECAY

    Directory of Open Access Journals (Sweden)

    R.I. Parovik

    2012-06-01

    Full Text Available In a model of radioactive decay of radon in the sample (222Rn. The model assumes that the probability of the decay of radon and its half-life depends on the fractal properties of the geological environment. The dependencies of the decay parameters of the fractal dimension of the medium.

  7. An overview of Ireland's National Radon Policy

    International Nuclear Information System (INIS)

    Long, S.; Fenton, D.

    2011-01-01

    In Ireland radon is a significant public health issue and is linked to 150-200 lung cancer deaths each year. Irish National Radon Policy aims to reduce individual risk by identifying and remediating buildings with high radon concentrations and also to reduce collective dose through radon prevention as required by revised building regulations. Achievements to date are significant and include the completion of the National Radon Survey, the testing of every school in Ireland, the on-going testing of social housing, collaboration between the public health and radiation protection authorities and the inclusion of radon in inspections of workplaces. However, this work now needs to be drawn together centrally to comprehensively address the radon problem. The RPII and the relevant central governing department, the Dept. of Environment, Heritage and Local Government are currently working to constitute a group of key experts from relevant public authorities to drive the development of a National Radon Control Strategy. (authors)

  8. Temperature dependence of the calibration factor of radon and radium determination in water samples by SSNTD

    CERN Document Server

    Hunyadi, I; Hakl, J; Baradacs, E; Dezso, Z

    1999-01-01

    The sensitivity of a sup 2 sup 2 sup 6 Ra determination method of water samples by SSNTD was measured as a function of storage temperature during exposure. The method is based on an etched track type radon monitor, which is closed into a gas permeable foil and is immersed in the water sample. The sample is sealed in a glass vessel and stored for an exposure time of 10-30 days. The sensitivity increased more than a factor of two when the storage temperature was raised from 2 deg. C to 30 deg. C. Temperature dependence of the partition coefficient of radon between water and air provides explanation for this dependence. For practical radio- analytical application the temperature dependence of the calibration factor is given by fitting the sensitivity data obtained by measuring sup 2 sup 2 sup 6 Ra standard solutions (in the activity concentration range of 0.1-48.5 kBq m sup - sup 3) at different storage temperatures.

  9. Radon mitigation in schools

    International Nuclear Information System (INIS)

    Leovic, K.W.; Craig, A.B.; Saum, D.W.

    1990-01-01

    This article reports on radon mitigation in school buildings. Subslab depressurization (SSD) has been the most successful and widely used radon reduction method in houses. Thus far, it has also substantially reduced radon levels in a number of schools. Schools often have interior footings or thickened slabs that may create barriers for subslab air flow if a SSD system is the mitigation option. Review of foundation plans and subslab air flow testing will help to determine the presence and effect of such barriers. HVAC systems in schools vary considerable and tend to have a greater influence on pressure differentials (and consequently radon levels) than do heating and air-conditioning systems encountered in the radon mitigation of houses. As part of any radon mitigation method, ASHRAE Standard 62-1989 should be consulted to determine if the installed HVAC system is designed and operated to achieve minimum ventilation standards for indoor air quality

  10. Evaluation of genetic alteration induced by radon gas using the micronucleus test (Tradescantia sp. clone KU-20)

    International Nuclear Information System (INIS)

    Bruschi, Armando L.; Azevedo, Heliana de; Macacini, Jose F.; Roque, Claudio V.

    2011-01-01

    The first observations over the existence of radon gas (Rn), initially known as 'thorium emanation', were carried out between the end of 19 th and beginning of 20 th centuries. A result of uranium-238 (U 238 ) radioactive decay, radon is a tasteless, odorless and colorless gas under room temperature, with a 3.825-day half life and particle α emission in its decay, and as final product of its disintegration, the stable lead-206 isotope (Pb 206 ). Being it is the gas with the highest density known, closed and poor ventilated environments are favorable to its accumulation, with its inhalation being the highest health risk. The use of vegetal bioindicators has shown to be excellent on the monitoring of air quality and on mutagenic potential of various pollutants contained in the atmosphere. Within this context, the objective of this study was to evaluate the micronucleus test application potential utilizing the Tradescantia sp. clone KU-20, in order to evaluate genetic alterations induced by radon gas. Stems of Tradescantia sp. clone KU-20, previously immerse in Hoagland solution, were introduced in a radon detection equipment's calibration chamber (Alphaguard), containing radium salt. Afterwards, the accommodated stems were exposed to radon gas (the average radon concentration was 7.639 KBq/m3) for 24 hours. The results demonstrated an increase on micronucleus formation (39.23 + 2.143 MCN/100 tetrads) in stems exposed in relation to the negative control (18.00 + 1.396 MCN/100 tetrads). The difference between the values indicated a significant increase on micronucleus frequency in the inflorescences subjected to radon gas. The presented results demonstrated the micronucleus test application potential using Tradescantia clone KU-20 to evaluate genetic effects induced by radon gas. (author)

  11. Estimation of radon emanation coefficient for soil and flyash

    International Nuclear Information System (INIS)

    Sahu, S.K.; Swarnkar, M.; Ajmal, P.Y.; Pandit, G.G.; Puranik, V.D.

    2012-01-01

    Since terrestrial materials include radium ( 226 Ra) originating from the decay of uranium ( 238 U), all such materials release radon ( 222 Rn) to varying degrees. When a radium atom decays to radon, the energy generated is strong enough to send the radon atom a distance of about 40 nanometers-this is known as alpha recoil. For a radon atom to escape the radium atom must be within the recoil distance from the grain surface of flyash or soil and the direction of recoil must send the radon atom toward the outside of the grain. Therefore, all of the radon atoms generated by the radium contained in flyash or soil grain are actually not released into pore spaces and mobilized. The fraction of radon atoms generated from radium decay that are released from into flyash or soil pore space is defined as the radon emanation coefficient or emanating power, of the material. Grain size and shape are two of the important factors that control the radon emanation coefficient because they determine in part how much uranium and radium is near enough to the surface of the grain to allow the newly-formed radon to escape into a pore space. In a porous medium, where the radon is in radioactive equilibrium with its parent radium, the emanation coefficient is given by the expression: where C 0 is the undiluted radon activity concentration in the pores of the medium, and C Ra is the radium activity concentration of the sample. The 226 Ra activity concentration of the flyash and soil sample were determined by using the g-spectrometry. C 0 was determined by the can experiment using LR-115 for flyash and soil samples. The C 0 values for flyash and soil samples were found to be 245.7 Bq/m 3 and 714.3 Bq/m 3 respectively. The radon emanation coefficient for flyash was found to be 0.0024 while that for soil was 0.0092. Therefore the soil sample was found to be four times higher radon emanation coefficient than flyash which is in line with the results reported in the literatures. This may suggest

  12. Radon concentration in spring and groundwater of Shillong agglomeration

    International Nuclear Information System (INIS)

    Walia, D.; Wahlang, P.; Lyngdoh, A.C.; Saxena, A.; Sharma, Y.; Maibam, D.

    2010-01-01

    Water samples in the month of February 2010 to April 2010 are collected from 06 springs (sample code S1-S6) and 18 wells (sample code W1-W18) of the Shillong agglomeration in radon-tight 1L bottles, considering the geological structures, nearness to the steep slopes and accessibility of the water sources. The measurement of radon in water samples is carried out using ionization chamber Alphaguard along with an accessory (fabricated in the laboratory). Initially, background radon of the empty set-up is measured for 30 minutes before every water-sample measurement. The water samples are placed in a closed gas cycle in degassing vessel and then radon is expelled using the pump and magnetic stirrer. The security vessel is connected with the degassing vessel to minimize the inflow of water vapour to the Alphaguard. The measuring cycle is repeated 3 times in order to obtain a better precision. The arithmetic mean of the radon concentrations are used for calculating the annual effective dose for ingestion of water from each bore well and spring. The pH, electrical conductivity and temperature are measured so as to correlate the meteorological parameters with the radon emanation

  13. Uranium and radon surveys in western Himalaya

    International Nuclear Information System (INIS)

    Virk, H.S.

    1997-01-01

    The water samples from mountain springs, streams and river systems in the western Himalaya were collected and analysed in the laboratory for uranium and radon contents. It is observed that the Himalayan river system is conspicuous by its high dissolved uranium and radium concentration. The water samples contain from 0.89 ppb to 63.4 ppb of uranium and from 34 Bq/I to 364 Bq/I of radon. The radon emanation in soil is measured by the track-etch method, emanometry and alpha-logger technique. The daily and long-term variation of radon was monitored in some mineralized zones of Himachal Pradesh (HP) state with high uranium content in the soil. The maximum values of radon are recorded in Chhinjra, Rameda, Samurkala and Kasol areas of HP. (author)

  14. Radon exhalation of cementitious materials made with coal fly ash: Part 2 - testing hardened cement-fly ash pastes

    International Nuclear Information System (INIS)

    Kovler, K.; Perevalov, A.; Levit, A.; Steiner, V.; Metzger, L.A.

    2005-01-01

    Increased interest in measuring radionuclides and radon concentrations in fly ash (FA), cement and other components of building products is due to the concern about health hazards of naturally occurring radioactive materials (NORM). The paper focuses on studying the influence of FA on radon exhalation rate (radon flux) from cementitious materials. In the previous part of the paper the state of the art was presented, and the experiments for testing raw materials, Portland cement and coal fly ash, were described. Since the cement and FA have the most critical role in the radon release process relative to other concrete constituents (sand and gravel), and their contribution is dominant in the overall radium content of concrete, tests were carried out on cement paste specimens with different FA contents, 0-60% by weight of the binder (cement+FA). It is found that the dosage of FA in cement paste has a limited influence on radon exhalation rate, if the hardened material is relatively dense. The radon flux of cement-FA pastes is lower than that of pure cement paste: it is about ∼3 mBq m -2 s -1 for cement-FA pastes with FA content as high as 960 kg m -3

  15. Radon levels in drinking water of Fatehabad district of Haryana, India

    International Nuclear Information System (INIS)

    Duggal, Vikas; Sharma, Samriti; Mehra, Rohit

    2017-01-01

    Radon concentrations were measured in 59 groundwater samples collected from Fatehabad district of Haryana, India. The measurements were performed by RAD7 an electronic radon detector manufactured by Durridge Company Inc. The measured radon concentration ranged from 1.4 to 22.6 Bq l −1 . 14% of the groundwater samples were above the United States Environmental Protection Agency recommended value for radon in water. The annual effective dose for ingestion and inhalation was also evaluated in this research. The total annual effective dose due to ingestion and inhalation of radon in drinking water varied from 14.1 to 221.8 µSv y −1 . - Highlights: • We report the radon concentration in 59 groundwater samples from Haryana. • The water samples were characterized by RAD7 radon detector. • A 14% of the groundwater samples were above the USEPA recommended value. • Total annual effective dose from 12 locations was above EU Council recommendations.

  16. Instruments to measure radon-222 activity concentration or exposure to radon-222. Intercomparison 2014

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2014-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by the Bundesamt fuer Strahlenschutz (BfS). A radon measuring service is recognized by the competent authority if it proves its organisational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the European Information System on Proficiency Testing Schemes (EPTIS) and from the BfS websites.

  17. EPA urges schools to check for radon

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    In April recommended that schools test their facilities for radioactive radon gas after examining preliminary test data from 130 schools scattered across the country which indicated that elevated radon levels may be at least as prevalent in schools as in private residences. EPA is recommending that schools test 100 percent of frequently-used rooms on the basement-level and ground-level floors. The agency also recommends that testing be conducted in the cooler months of the year when doors and windows are likely to be closed. As part of a study to gather more information about measuring radon in schools, EPA tested approximately 3000 classrooms in 16 states. The states are widely distributed across the country. Of the total number of rooms, 54 percent had at least one room with a radon level above four picocuries per liter of air pCi/L. Nineteen percent had radon levels above four pCi/L. Three percent of the classrooms measured had radon level over 20 pCi/L. Each of the 16 states had a school with one measurement over four pCi/L, and one school had levels as high as 136 pCi/L

  18. Radon anomalies along faults in North of Jordan

    International Nuclear Information System (INIS)

    Al-Tamimi, M.H.; Abumurad, K.M.

    2001-01-01

    Radon emanation was sampled in five locations in a limestone quarry area using SSNTDs CR-39. Radon levels in the soil air at four different well-known traceable fault planes were measured along a traverse line perpendicular to each of these faults. Radon levels at the fault were higher by a factor of 3-10 than away from the faults. However, some sites have broader shoulders than the others. The method was applied along a fifth inferred fault zone. The results show anomalous radon level in the sampled station near the fault zone, which gave a radon value higher by three times than background. This study draws its importance from the fact that in Jordan many cities and villages have been established over an intensive faulted land. Also, our study has considerable implications for the future radon mapping. Moreover, radon gas is proved to be a good tool for fault zones detection

  19. Radon in soil gas

    International Nuclear Information System (INIS)

    Rector, H.E.

    1990-01-01

    This paper presents the results of a technology review conducted to identify and organize the range of options for measuring radon in soil gas as a means to evaluate radon exposure potential in buildings. The main focus of the review includes identifying the following: Measurement of objectives - the specific parameter(s) that each technology is designed to measure( e.g., soil gas concentration, flux density, etc.); Equipment needs -commercial availability of systems and/or components, specifications for fabricated components; Procedural information - documented elements of field and laboratory methodology and quality assurance; Underlying assumptions - conceptual and mathematical models utilized to convert analytical outcomes to estimators of radon. Basic technologies and field data were examined from a generic perspective (e.g., the common denominators of passive detectors, hollow sampling probes, flux monitors)( as well as specific configurations developed by individual investigators (e.g., sample volume, depth) to develop the basis for separating analytical uncertainties form sampling uncertainties

  20. Spatial radon anomalies on active faults in California

    International Nuclear Information System (INIS)

    King, C.-Y.; King, B.-S.; Evans, W.C.; Wei Zhang

    1996-01-01

    Radon emanation has been observed to be anomalously high along active faults in many parts of the world. We tested this relationship by conducting and repeating soil-air radon surveys with a portable radon meter across several faults in California. The results confirm the existence of fault-associated radon anomalies, which show characteristic features that may be related to fault structures but vary in time due to other environmental changes, such as rainfall. Across two creeping faults in San Juan Bautista and Hollister, the radon anomalies showed prominent double peaks straddling the fault-gouge zone during dry summers, but the peak-to-background ratios diminished after significant rain fall during winter. Across a locked segment of the San Andreas fault near Olema, the anomaly has a single peak located several meters southwest of the slip zone associated with the 1906 San Francisco earthquake. Across two fault segments that ruptured during the magnitude 7.5 Landers earthquake in 1992, anomalously high radon concentration was found in the fractures three weeks after the earthquake. We attribute the fault-related anomalies to a slow vertical gas flow in or near the fault zones. Radon generated locally in subsurface soil has a concentration profile that increases three orders of magnitude from the surface to a depth of several meters; thus an upward flow that brings up deeper and radon-richer soil air to the detection level can cause a significantly higher concentration reading. This explanation is consistent with concentrations of carbon dioxide and oxygen, measured in soil-air samples collected during one of the surveys. (Author)

  1. Variance of indoor radon concentration: Major influencing factors

    Energy Technology Data Exchange (ETDEWEB)

    Yarmoshenko, I., E-mail: ivy@ecko.uran.ru [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation); Vasilyev, A.; Malinovsky, G. [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation); Bossew, P. [German Federal Office for Radiation Protection (BfS), Berlin (Germany); Žunić, Z.S. [Institute of Nuclear Sciences “Vinca”, University of Belgrade (Serbia); Onischenko, A.; Zhukovsky, M. [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation)

    2016-01-15

    Variance of radon concentration in dwelling atmosphere is analysed with regard to geogenic and anthropogenic influencing factors. Analysis includes review of 81 national and regional indoor radon surveys with varying sampling pattern, sample size and duration of measurements and detailed consideration of two regional surveys (Sverdlovsk oblast, Russia and Niška Banja, Serbia). The analysis of the geometric standard deviation revealed that main factors influencing the dispersion of indoor radon concentration over the territory are as follows: area of territory, sample size, characteristics of measurements technique, the radon geogenic potential, building construction characteristics and living habits. As shown for Sverdlovsk oblast and Niška Banja town the dispersion as quantified by GSD is reduced by restricting to certain levels of control factors. Application of the developed approach to characterization of the world population radon exposure is discussed. - Highlights: • Influence of lithosphere and anthroposphere on variance of indoor radon is found. • Level-by-level analysis reduces GSD by a factor of 1.9. • Worldwide GSD is underestimated.

  2. Radon Mapping of the Osijek Town

    International Nuclear Information System (INIS)

    Radolic, V.; Faj, Z.; Smit, G.; Culo, D.; Planinic, J.

    1998-01-01

    After ten years investigation of radon seasonal variations at three very different locations, as well as radon concentration measurements in kindergartens and schools, systematical indoor radon measurements were undertaken in dwellings of Osijek. Indoor radon was measured by means of the LR-115 nuclear track detector at 48 town locations that gave the arithmetic mean of 71.6 Bq m -3 , standard deviation of 44.0 Bq m -3 and geometric mean of 60.1 Bq m -3 , for the radon concentration range from 23 to 186 Bq m -3 . The empirical frequency distribution of radon concentrations, with the class width of 20 Bq m -3 , was in accordance with the theoretical log-normal distribution which was shown with χ 2 - test. The radon map pointed out a region of higher radon concentrations (central part of the town) that was ascribed to the geological soil structure. Thus supposition was confirmed by radon measurement in the soil gas using radon emanators with the LR-115 film that showed the positive correlation between radon concentrations in the soil and indoors. Radon measurements in Osijeks primary schools pointed out a school that had the highest radon concentration (300 Bq m -3 ) considering all the former indoor radon measurements. The radon distribution in the school building was investigated afterwards radon mitigation procedures were undertaken. (author)

  3. A contemporary method for monitoring indoor radon and environmental conditions at a remote test site

    International Nuclear Information System (INIS)

    Renken, K.J.; Coursin, S.

    1996-01-01

    A state-of-the-art method for automatically monitoring indoor radon and environmental conditions at a remote test site is described. A Wisconsin home that exhibited elevated radon levels has been installed with automated PC-data acquisition system (PC-DAS) that includes: a laptop PC, a data acquisition cardcage, a commercial data acquisition software program plus sensors to measure radon gas concentrations, differential pressures, indoor air quality and meteorological conditions. The isolated PC-DAS is connected to a PC in a university laboratory via a modem and a communications software package. Experimental data is monitored and saved by the remote PC in real time and then automatically downloaded to the lab computer at selected intervals. An example of the formatted field results is presented and analysed. This documentation of the set-up, the off-the-shelf computer hardware and software, and the procedures should assist investigations requiring flexible remote long-term radon and environmental monitoring. (Author)

  4. Sources and protective measures of indoor radon

    International Nuclear Information System (INIS)

    Gou Quanlu; Wang Hengde

    1993-01-01

    This paper presents the relative contribution to indoor radon 222 Rn of various sources in twenty three rooms of three kinds in Taiyuan area. The results show that the major sources in this area are radon emanation from surfaces of soil and building materials and that from outdoor air, while the contribution of water and gas consumed in the rooms is less important. These results suggest a basis for taking suitable protective measures against indoor radon. Some materials are also recommended which are effective in restraining radon exhalation and low in price, by testing more than ten kinds of materials and comparing them using cost-effectiveness analysis technique, such as painting materials, polyvinyl alcohol (CH 2 :CHOH)n, etc. Their sealing effects on radon exhalation were examined with home-made REM-89 Radon Exhalation Monitor. The deposition effects of negative ion generator and humidifier on radon progeny were also tested. The maximum deposition may reach 70-90%, which proves they are also effective and economical in radon protection. (2 tabs., 3 figs.)

  5. Radiation dose due to radon and heavy metal analysis in drinking water samples of Jammu District, Jammu and Kashmir, India

    International Nuclear Information System (INIS)

    Kumar, A.; Kaur, M.; Sharma, S.; Mehra, R.; Sharma, D.K.; Mishra, R.

    2016-01-01

    In the present investigation, radon concentration and heavy metal analysis were carried out in drinking water samples in Jammu district, Jammu and Kashmir, India. The radon concentration was measured by using RAD-7, portable alpha particle detector. The values of radon concentration in drinking water samples were also compared within the safe limit recommended by different health agencies. The total annual effective dose ranged from 53.04 to 197.29 μSv y -1 . The annual effective dose from few locations from the studied area was found to be greater than the safe limit (100 μSv y -1 ) suggested by World Health Organisation (WHO) and EU Council. Heavy metal concentration was determined by atomic absorption spectrophotometer. A total of eight elements were analysed, viz. arsenic, mercury, zinc, iron, copper, chromium, manganese and cadmium. Heavy metals are considered to be the major pollutants of water sources. The results were compared with the limits of WHO, EU and Indian organisations. The trace metal analysis is not on the exceeding side of the permissible limit in all the samples. (authors)

  6. Surveys of radon levels in homes in the United States: A test of the linear-no-threshold dose-response relationship for radiation carcinogenesis

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1987-01-01

    The University of Pittsburgh Radon Project for large scale measurements of radon concentrations in homes is described. Its principal research is to test the linear-no threshold dose-response relationship for radiation carcinogenesis by determining average radon levels in the 25 U.S. counties (within certain population ranges) with highest and lowest lung cancer rates. The theory predicts that the former should have about 3 times higher average radon levels than the latter, under the assumption that any correlation between exposure to radon and exposure to other causes of lung cancer is weak. The validity of this assumption is tested with data on average radon level vs replies to items on questionnaires; there is little correlation between radon levels in houses and smoking habits, educational attainment, or economic status of the occupants, or with urban vs rural environs which is an indicator of exposure to air pollution

  7. Secular variations of radon in metropolitan Vancouver, British Columbia, Canada

    International Nuclear Information System (INIS)

    Ghomshei, M.M.; Slawson, W.F.

    1990-01-01

    In this paper sampling of radon within the soil from three sites in metropolitan Vancouver is reported. Alpha trace bi-weekly measurements during a period of 4 years show secular variations with a period of 8-15 months. There are low-radon and high-radon episodes enduring several months to a year. Average radon level during the high-radon episodes reaches 5-10 times that of the low-radon periods. During high-radon episodes the high-frequency variations show very high amplitudes. After filtering of the high-frequency fluctuations, the data from different sites demonstrate remarkably similar trends. It is suggested that along with hydrogeological events, stress relaxation in rocks, earthquake, and magma emplacement may contribute to the sources of secular variations of radon. Because of long-term variations, radon level in urban areas should be monitored on a continuous basis. Single measurements, even those integrating radiation over a period of few months, may sample a low-radon episode, and provide a false assurance, or occur during a high-radon episode and give a false alarm

  8. Procedure for the characterization of radon potential in existing dwellings and to assess the annual average indoor radon concentration

    International Nuclear Information System (INIS)

    Collignan, Bernard; Powaga, Emilie

    2014-01-01

    Risk assessment due to radon exposure indoors is based on annual average indoor radon activity concentration. To assess the radon exposure in a building, measurement is generally performed during at least two months during heating period in order to be representative of the annual average value. This is because radon presence indoors could be very variable during time. This measurement protocol is fairly reliable but may be a limiting in the radon risk management, particularly during a real estate transaction due to the duration of the measurement and the limitation of the measurement period. A previous field study defined a rapid methodology to characterize radon entry in dwellings. The objective of this study was at first, to test this methodology in various dwellings to assess its relevance with a daily test. At second, a ventilation model was used to assess numerically the air renewal of a building, the indoor air quality all along the year and the annual average indoor radon activity concentration, based on local meteorological conditions, some building characteristics and in-situ characterization of indoor pollutant emission laws. Experimental results obtained on thirteen individual dwellings showed that it is generally possible to obtain a representative characterization of radon entry into homes. It was also possible to refine the methodology defined in the previous study. In addition, numerical assessments of annual average indoor radon activity concentration showed generally a good agreement with measured values. These results are encouraging to allow a procedure with a short measurement time to be used to characterize long-term radon potential in dwellings. - Highlights: • Test of a daily procedure to characterize radon potential in dwellings. • Numerical assessment of the annual radon concentration. • Procedure applied on thirteen dwellings, characterization generally satisfactory. • Procedure useful to manage radon risk in dwellings, for real

  9. Workshop on dosimetry for radon and radon daughters

    International Nuclear Information System (INIS)

    Turner, J.E.; Holoway, C.F.; Loebl, A.S.

    1978-05-01

    Emphasis is placed on the dosimetry for radon and daughters, rather than on monitoring and instrumentation. The objectives of the meeting were to exchange scientific information, to identify problem areas in radon-daughter dosimetry, and to make any observations or recommendations by the participants through issuance of this report. The discussion topics included the history of dosimetry for radon and daughters, human data, aerosols, deposition and movement in the respiratory tract, dose calculations, dose-to-working-level-month (WLM) conversion factors, animal experiments, and the development of regulations and remedial criteria for reducing population exposures to radon daughters. This report contains a summary of Workshop discussions plus individual statements contributed by several of the participants. The outstanding problem areas from the standpoint of dosimetry appear to involve the appropriate lung organ mass to be used (average lung-tissue dose vs. high-level local dose); recognition of the discrete, rather than continuous, structure of the mucus; lack of knowledge about lung clearance; the variability of dose with the degree of disequilibrium and the unattached fraction of radon daughters for a given WLM; and questions about the character of uranium mine atmospheres actually breathed in the older mines from which much of the epidemiological information originates. The development of criteria for taking remedial action to reduce exposures involves additional concerns of basing long-term risk assessment on short-term sampling and applying WLM data for miners to general populations

  10. Standardization of radon measurements

    International Nuclear Information System (INIS)

    Matuszek, J.M.; Hutchinson, J.A.; Lance, B.H.; Virgil, M.G.; Mahoney, R.J.

    1988-01-01

    Radon escaping from soil into homes appears to present the single greatest source of radiation exposure that most people will ever face. Measurement protocols for the relatively inert gas inextricably link the method of collection with the counting of the specimen. The most commonly used methods depend on the measurement of dislocation sites on plastic α-track detectors or on the adsorption of radon onto activated charcoal for subsequent counting of the γ-rays produced by decay of the radon progeny. The uncertainties inherent to the radon-measurement methods used commercially in the United States are far greater than those for measurements of other environmental radionuclides. The results of this preliminary study raise doubts as to whether existing proficiency-testing programs can provide assurance that radon-measurement methods are representative of actual conditions in any dwelling. 17 refs., 1 figs., 4 tabs

  11. Development of a portable radon detection system

    International Nuclear Information System (INIS)

    Allen, J.W.

    1976-09-01

    The presence of radon-222 in soil gas and ground water can indicate the existence of nearby uranium deposits even when heavy overburdens completely absorb the associated gamma radiation. Techniques to detect and measure radon have evolved during the past several years to the point where radon prospecting is routinely employed in a number of countries. A program to develop and field test a prototype system for measuring radon from soil gas and water is described. A prototype system employing a flow through scintillation detector was designed and constructed, utilizing standard commercial components, to provide a fieldworthy unit for testing the system concepts. Laboratory and preliminary field tests of this unit indicate that it can detect anomalous radon levels of less than 10 picoCuries per liter (pCi/l) in soil gas and ground water

  12. Control of indoor radon and radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-05-01

    There are three general categories of techniques for the control of radon and radon progeny concentrations in indoor air - restriction of radon entry, reduction of indoor radon concentrations by ventilation or air cleaning, and removal of airborne radon progeny. The predominant radon entry process in most residences appears to be pressure driven flow of soil gas through cracks or other openings in the basement, slab, or subfloor. Sealing these openings or ventilation of the subslab or subfloor space are methods of reducing radon entry rates. Indoor radon concentrations may be reduced by increased ventilation. The use of charcoal filters for removal of radon gas in the indoor air by adsorption has also been proposed. Concentrations of radon progeny, which are responsible for most of the health risks associated with radon exposures, can be controlled by use of electrostatic or mechanical filtration. Air circulation can also reduce radon progeny concentrations in certain cases. This paper reviews the application and limitations of each of these control measures and discusses recent experimental results

  13. Radon in Croatian spas

    International Nuclear Information System (INIS)

    Radolic, V.; Vukovic, B.; Planinic, J.

    2004-01-01

    There are ten thermal spas in Croatia and all of them provide health services for patients and visitors. Radon measurements were performed since there is a lack of data concerning natural radioactivity originated from radon and its short-lived progenies in such environments. The thermal water at two different sites (the indoor swimming pool with geothermal water and the spring) in each spa was sampled and radon concentrations were measured by AlphaGUARD radon measuring system. The obtained values were in the range of 0.7 to 19 Bq.dm -3 and 2 to 94 Bq.dm -3 for indoor swimming pools and springs, respectively. Integrated measurements of radon concentration in air were performed by two solid state nuclear track detectors LR-115 II (open and diffusion one) thus enabling estimation of equilibrium factor between radon and its daughters. The annual effective doses received by spa workers were found to be about 1 mSv/y (below the lower limit value of 3 mSv/y recommended by ICRP 65). The doses of patients and visitors were one or two order of magnitude lower than that of the personnel. (author)

  14. Comparison of calculated and measured soil-gas radon concentration and radon exhalation rate

    International Nuclear Information System (INIS)

    Neznal, Martin; Neznal, Matej; Jiranek, Martin

    2000-01-01

    The computer model RADON2D for WINDOWS, which makes it possible to estimate the radon exhalation rate from the ground surface and the distribution of soil-gas radon concentration, was tested using a large set of experimental data coming from four reference areas located in regions with different geological structure. A good agreement between calculated and experimental data was observed. In the majority of cases, a correct description of the real situation was obtained using non-modified experimental input data. (author)

  15. Current status of radon and radium monitoring at the Federal University of Technology (UTFPR), PR, Brazil

    International Nuclear Information System (INIS)

    Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Schelin, Hugo R.; Denyak, Valeriy; Barbosa, Laercio; Perna, Allan F.N.

    2011-01-01

    Numerous and systematic studies performed in different countries for many decades resulted in the explicit conclusion that radon exposure, as well as its progeny, is the main cause of lung cancer among non-smokers. All three natural radon isotopes ( 222 Rn, 220 Rn and 219 Rn) are produced in the three principal natural radioactive decay chains. Specifically, the 222 Rn is produced by the decay series of 238 U and proceeded from α-decay of 226 Ra. Current work describes the present status and obtained results concerning indoor radon survey in dwellings, radon in water supply and soil gas tests performed by the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR) within Curitiba urban area. For radon in air activity measurements, it was used polycarbonate etched track detectors such as LEXAN (GE) and CR-39, mounted in diffusion chambers. For soil gas measurements, the experimental setup was based on the Professional Radon Monitor (AlphaGUARD, Genitron/SAPHYMO) connected to the air pump with filter vessels and to specially developed in our Laboratory the Soil Gas Probe. In the case of radon tests in drinking water, the experimental setup was based on the AlphaGUARD Radon monitor and Electronic radon detector RAD7 (Durridge Company, Inc.) connected to special kit of glass vessels through the air pump. Obtained results permitted to identify few dwellings where radon concentration in air was found bigger than 600 Bq/m 3 which is considered as the action level by most of the European Community and the World Health Organization (WHO). In the case of studied artesian wells, collected samples of water presented the average 222 Rn activity about 60 Bq/L which is 6 times bigger than maximum level recommended by USEPA. Some artesian wells presented the radon activity of almost 200 Bq/L. More over, it was identified the radioactivity of radium ( 226 Ra) salts which are soluble in water and almost all water samples presented results bigger than

  16. Radon concentration measurements in waters in Greece and Cyprus

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Tzortzi, A.; Thanassas, D.; Serefoglou, A.; Georgiou, E.; Vogiannis, E.; Koukouliou, V.

    2004-01-01

    The radon content of drinking water samples was determined with Alpha Guard Pro equipped with an appropriate unit (Aqua Kit). The samples were collected from water taps in dwellings located at various cities in Greece and Cyprus. In addition, surface water samples from rivers, lakes and seas as well as potable underground and hot spring water samples from Greece and Cyprus were also collected. For a precise determination of radon concentration in water samples, special procedures were followed both for sampling and transportation, as well as for measurement. Intercomparison experiments were designed and implemented before and during the study. Radon concentrations in drinking water samples in Greece ranged between 1.1 ± 0.5 Bq/L and 410±50 Bq/L. The corresponding concentrations in Cyprus ranged between 1.3 ± 0.8 Bq/L and 15±4 Bq/L. Three samples collected from the city of Arnea Chalkidikis (Northern Greece) exhibited high concentrations of 120±20 Bq/L, 320±40 Bq/L and 410±50 Bq/L. This city is identified as a high radon potential area. One water sample located in Lesvos Island (North-East part of Greece) exhibited radon concentration 140±20 Bq/L. Additional six samples displayed high concentrations in potable hot spring water samples. These samples which were collected from the city of Loutraki (Peloponnesus) ranged between 220-230 Bq/L. In addition, two samples characterized as 'medicinal drinking water' gave concentrations between 320 Bq/L and 340 Bq/L. For underground water samples the radon concentrations ranged between 1.2±0.7 Bq/L and 15±4 Bq/L, while for surface water samples the range was 2.7±0.8 Bq/L to 24±6 Bq/L. The observed concentrations of radon gas in potable water samples in Greece were found to be largely low. In Cyprus, they were all well below 15 Bq/L

  17. Radon monitoring technique with electret collecting

    International Nuclear Information System (INIS)

    Tian Zhiheng; Zuo Fuqi; Xiao Detao; Zhao Xkiuliang

    1991-12-01

    The integrating radon monitoring technique with electret collecting is a method which collects the 218 Po + positive ions by electrostatic field produced by electret. It has greatly improved the sensitivity of radon measurement. The response factor of this method reaches to 4.7 cm -2 Bq -1 m 3 h -1 , 1000 times larger than that of common passive sampling method. The monitoring device and its principle are introduced. The measuring results of radon concentration and radon flux rate and quality assurance system by using this method in the Qinshan Nuclear Power Plant, Human Environmental Monitoring Central Station and some uranium mines are also presented. The analytical results show that the radon concentration in the Qinshan Nuclear Power Plant is affected by wind direction. When wind directs toward sea, the radon concentration is high. If the wind is to the contrary, it is low. The radon concentration ratio of both is about 2

  18. Radon emanation coefficients in sandy soils

    International Nuclear Information System (INIS)

    Holy, K.; Polaskova, A.; Baranova, A.; Sykora, I.; Hola, O.

    1998-01-01

    In this contribution the results of the study of an influence of the water content on the emanation coefficient for two sandy soil samples are reported. These samples were chosen on the because of the long-term continual monitoring of the 222 Rn concentration just in such types of soils and this radon concentration showed the significant variations during a year. These variations are chiefly given in connection with the soil moisture. Therefore, the determination of the dependence of the emanation coefficient of radon on the water content can help to evaluate the influence of the soil moisture variations of radon concentrations in the soil air. The presented results show that the emanation coefficient reaches the constant value in the wide interval of the water content for both sandy soil samples. Therefore, in the common range of the soil moisture (5 - 20 %) it is impossible to expect the variations of the radon concentration in the soil air due to the change of the emanation coefficient. The expressive changes of the radon concentration in the soil air can be observed in case of the significant decrease of the emanation coefficient during the soil drying when the water content decreases under 5 % or during the complete filling of the soil pores by the water. (authors)

  19. Method for measurement of radon diffusion and solubility in solid materials

    Science.gov (United States)

    Maier, Andreas; Weber, Uli; Dickmann, Jannis; Breckow, Joachim; van Beek, Patrick; Schardt, Dieter; Kraft, Gerhard; Fournier, Claudia

    2018-02-01

    In order to study the permeation i.e. the diffusion and solubility of radon gas in biological material, a new setup was constructed and a novel analysis was applied to obtain diffusion and solubility coefficients. Thin slabs of solid materials were installed between detector housing and the surrounding radon exposure chamber of 50 Ls volume. In this setup radon can diffuse through thin test samples into a cylindrical volume of 5 mm height and 20 mm diameter and reach an α-particle detector. There the 5.49 MeV α-decay of the penetrating radon atoms is measured by a silicon surface barrier detector. The time dependent activities inside the small detector volume are recorded after injection of a known radon activity concentration into the outer chamber. Analyzing the time behavior of the integral α-activity from radon in the small vessel, both, the diffusion coefficient and solubility of the test material can be determined, based on a new mathematical model of the diffusion process concerning the special boundary conditions given by the experimental setup. These first measurements were intended as proof of concept for the detection system and the data analysis. Thin polyethylene foils (LDPE) were selected as material for the diffusion measurements and the results were in agreement with data from literature. In further measurements, we will concentrate on biological material like bone, fat and other tissues.

  20. Method of reducing radon levels in buildings

    International Nuclear Information System (INIS)

    Khajdarov, R.A.; Gapurova, O.U.; Khajdarov, R.R.

    2004-01-01

    Radon concentration can be reduced by using polymeric compositions which fill pores inside building materials and decrease the coefficient of permeation of radon atoms and water molecules in building materials (concrete, gypsum, etc.). Polymeric silico-organic compounds were investigated and selected as the chemicals to prevent radon seeping indoors. Gas (air, Ar, 222 Rn, H 2 O) permeability of concrete and gypsum after treatment with chemicals was examined. The effect of the cement and sand types, preliminary treatment with various chemicals, type of the polymeric silico-organic compounds, time between treatments, moisture of concrete, time between the preparation of chemicals and the treatment of concrete (ageing of chemicals), time between the treatment of concrete and testing (ageing of treated concrete) were examined. Surfaces of the samples were treated by spraying. The experiments gave evidence that the chosen method of treatment of the construction materials allows reducing the coefficient of gas permeability in 200 - 400 times. Treatment of the floor, walls and ceiling of the basement of 5 buildings reduced the radon concentration in the premises of the first floor from 400-600 Bq/m 3 to the background value of 17-20 Bq/m 3

  1. Ten practical lessons for an effective radon risk communication program

    International Nuclear Information System (INIS)

    Fisher, A.; Johnson, F.R.

    1990-01-01

    Those responsible for state and local radon programs often express frustration about the small share of homes that have been tested for radon, and the small share of those with high readings that have been mitigated. Several recent studies have examined how well alternative ways of communicating about radon's risk have accomplished the goals of motivating appropriate testing and mitigation. Unfortunately, the results of these studies have not reached practitioners. This paper is for them. It summarizes the practical implications that are most crucial for planning and implementing an effective radon risk communication program--a program that will motivate people to test for radon and mitigate when radon levels are high, without unduly alarming those whose radon levels are low

  2. Study of temporal variation of radon concentrations in public drinking water supplies

    International Nuclear Information System (INIS)

    York, E.L.

    1995-01-01

    The Environmental Protection Agency (EPA) has proposed a Maximum Contaminant Level (MCL) for radon-222 in public drinking water supplies of 300 pCi/L. Proposed monitoring requirements include collecting quarterly grab samples for the first year, then annual samples for the remainder of the compliance cycle provided first year quarterly samples average below the MCL. The focus of this research was to study the temporal variation of groundwater radon concentrations to investigate how reliably one can predict an annual average radon concentration based on the results of grab samples. Using a open-quotes slow-flowclose quotes collection method and liquid scintillation analysis, biweekly water samples were taken from ten public water supply wells in North Carolina (6 month - 11 month sampling periods). Based on study results, temporal variations exist in groundwater radon concentrations. Statistical analysis performed on the data indicates that grab samples taken from each of the ten wells during the study period would exhibit groundwater radon concentrations within 30% of their average radon concentration

  3. Radon

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, F [Muenchen Univ. (Germany, F.R.). Inst. fuer Anorganische Chemie

    1978-09-01

    The noble gas radon, formerly called emanation, was discovered a few years after radium. /sup 222/Rn, the longest-lived isotope, has a half-life of 3,82 days. This half life is so short that the experimental techniques available at present (1978) are not sufficient for a characterization of defined radon compounds, even though there are definite indications for the existence of such compounds, and one may expect such radon compounds to be even more stable than the numerous known xenon compounds. - The radon isotopes /sup 219/Rn (Actinon), /sup 220/Rn (Thoron), and /sup 222/Rn (Radon) occur in nature despite their rather short half-lives, because they are continously generated from their mothers /sup 223/Ra, /sup 224/Ra, and /sup 226/Ra, which are in secular equilibrium with long-lived isotopes /sup 235/U, /sup 238/U, and /sup 232/Th, and are in turn continously formed from these long-lived isotopes. Since the radon isotopes are gases, they enter the atmosphere and are carried for long distances with air currents. - Because radon is so short-lived, its practical applications are rather limited. For medical applications, small sealed glass tubes filled with radon are used as radiation sources after the radon has decayed, because the whole series of Po-, Bi-, and Pb-isotopes of the radium decay chain are formed, whose penetrating radiation is useful for therapy. When solids are spiked with Ra isotopes, radon is evolved at a constant rate. On heating such solids, phase transitions show up by sudden increased radon evolution (Hahn's emanation method). - On the basis of nuclear theoretical calculations, there is hardly a chance for the discovery of a long-lived radon species. Therefore, major progress in radon chemistry is hardly to be expected in the near future.

  4. Radon concentration of waters in Greece and Cyprus

    Science.gov (United States)

    Nikolopoulos, D.; Vogiannis, E.; Louizi, A.

    2009-04-01

    Radon (222Rn) is a radioactive gas generated by the decay of the naturally occurring 238U series. It is considered very important from radiological point of view, since it is the most significant natural source of human radiation exposure (approximately 50% from all natural sources). Radon is present in soil, rocks, building materials and waters. Through diffusion and convection, radon migrates and emanates to the atmosphere. Outdoors, radon concentrates at low levels (in the order of 10 Bq/m3). However indoors, radon accumulates significantly. It is trivial to observe indoor environments with high radon levels (in the order of 400 Bq/m3 or higher). Radon accumulation indoors, depends on the composition of the underlying soil and rock formation, on building materials, meteorological parameters, ventilation, heating and water use. Although soil and building materials are the most significant radon sources, there have been reported elevated radon concentrations in building structures due to entering water. It is the radon concentrations in the entering water, the volume and the way of water usage, separated or in combination, that result in large amounts of radon in indoor air. Moreover, radon is a factor of stomach radiation burden due to water consumption. This burden is estimated by measurements of radon concentrations in waters. Due to the health impact of radon exposure, the reporting team continuously measures radon. This work focused on the radon concentrations exposure due to water consumption and use in Greece and Cyprus. Various locations in Greece and Cyprus were accessed taking into consideration existing natural radioactivity data (mainly radon in water), however under the restriction of the capability of movement. Radon in water was measured by Alpha Guard (Genitron Ltd) via a special unit (Aqua Kit). This unit consists of a vessel used for forced degassing of radon diluted in water samples, a security vessel used for water drop deposition. Vessels and

  5. An approach to discriminatively determine thoron and radon emanation rates for a granular material with a scintillation cell

    International Nuclear Information System (INIS)

    Sakoda, Akihiro; Meisenberg, Oliver; Tschiersch, Jochen

    2016-01-01

    A powder sandwich technique was applied to determine thoron ("2"2"0Rn) and radon ("2"2"2Rn) emanation rates for a granular material. The feature of this technique is the sample preparation, in which a granular material is put and fixed between two membrane filters. Airflow is directly given to this sandwich sample, will include thoron and radon emanated from the material, and then is transferred to the detector. This method makes sure that thoron and radon emanated are not retained in pore space within the sample volume, which is crucial for the appropriate emanation test. This technique was first introduced by Kanse et al. (2013) with the intention to measure the emanation of thoron - but not of radon - from materials having much higher "2"2"4Ra activity than "2"2"6Ra. In the present study, the methodology for the discriminative determination of thoron and radon emanation rates from a granular material has been examined using a flow-through scintillation cell and sandwich sample. The mathematical model was developed to differentiate total alpha counts into thoron- and radon-associated counts. With a sample of uranium ore, this model was experimentally validated by comparison between the scintillation cell and a reference detector that can discriminatively measure thoron and radon concentrations. Furthermore, the detection limits and uncertainties were evaluated to discuss the characteristics of this method. Key parameters for improving the determination of thoron and radon emanations were found to be the background radon concentration and the leakage of radon from the measurement system, respectively. It was concluded that the present method is advantageous to a sample that has much higher "2"2"6Ra activity than "2"2"4Ra. - Highlights: • The methodology of appropriate and discriminative measurement of thoron and radon emanation is presented. • Measurement of thoron and radon emanated from a sample was made using a scintillation cell. • Detection limits and

  6. A radon progeny deposition model

    International Nuclear Information System (INIS)

    Rielage, Keith; Elliott, Steven R.; Hime, Andrew; Guiseppe, Vincent E.; Westerdale, S.

    2010-01-01

    The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly 222 Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of 210 Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

  7. A Radon Progeny Deposition Model

    International Nuclear Information System (INIS)

    Guiseppe, V. E.; Elliott, S. R.; Hime, A.; Rielage, K.; Westerdale, S.

    2011-01-01

    The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly 222 Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of 210 Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

  8. Measurements of radon and chemical elements: Popocatepetl volcano

    International Nuclear Information System (INIS)

    Pena, P.; Segovia, N.; Lopez, B.; Reyes, A.V.; Armienta, M.A.; Valdes, C.; Mena, M.; Seidel, J.L.; Monnin, M.

    2002-01-01

    The Popocatepetl volcano is a higher risk volcano located at 60 Km from Mexico City. Radon measurements on soil in two fixed seasons located in the north slope of volcano were carried out. Moreover the radon content, major chemical elements and tracks in water samples of three springs was studied. The radon of soil was determined with solid detectors of nuclear tracks (DSTN). The radon in subterranean water was evaluated through the liquid scintillation method and it was corroborated with an Alpha Guard equipment. The major chemical elements were determined with conventional chemical methods and the track elements were measured using an Icp-Ms equipment. The radon on soil levels were lower, indicating a moderate diffusion of the gas across the slope of the volcano. The radon in subterranean water shown few changes in relation with the active scene of the volcano. The major chemical elements and tracks showed a stable behavior during the sampling period. (Author)

  9. Radon and its measurement

    International Nuclear Information System (INIS)

    Penzo, Silvia

    2006-03-01

    The work reviews the topics concerning the problem of the indoor radon and its measurement. The initial stage deals with the general features of radon, from the historical remarks about its discovery to the formation mechanisms in the soil, then passing to describe the transport processes that lead the radon to enter into the buildings. The mean radon concentration distribution among the Italian regions is reported and compared with the situation in the other countries of the world. A particular importance is given to present the national law concerning the radioprotection from the natural sources of ionizing radiations; a paragraph is completely devoted to this argument and to discuss the differences between the Italian approach and the regulations applied in the Test of Europe for both workplaces and dwellings. Chapter 3 describes the different detectors and methods to measure the radon and its short mean live decay products concentrations, together with the operative procedures and guides provided by the Italian law and by the international bodies. As an example of typical radon passive measurement device. the new ENEA detector developed at the Institute of Radioprotection is presented and discussed. Appendix 1 is entirely devoted to discuss the main remedial actions for decreasing the radon indoor concentration both for old and new buildings; appendix 2 reports the main quantities related to radon and radioprotection [it

  10. Typhoon and elevated radon level in a municipal water supply

    International Nuclear Information System (INIS)

    Mao, Cheng-Hsin; Weng, Pao-Shan

    2000-01-01

    The Municipal Water Supply at Hsinchu City is a water treatment plant using poly- aluminum chloride (PAC) for coagulation and then followed by precipitation and filtration. Its capacity is 70,000 m 3 /day. The raw water is drawn from the nearby river. Since the subject of interest is the radon level during typhoon season, the sampling period was from March to December 1999. Commercially available electret was used for water samples taken from the five ponds in the plant. This technique relies on the measurement of radon in air above a water sample enclosed in a sealed vessel. The concentration of airbone radon released from water was determined by means of the electret ion chamber. During the first sampling period there came two typhoons. One is called Magie during June 10-17, and the other called Sam during August 20-26. The first typhoon led to the radon level measured from the water samples as high as 705 Bq/m 3 , while the second caused even higher radon level as high as 772 Bq/m 3 . Similar results were obtained for the second sampling period after August till December 1999. For those measured without typhoon influence, the average radon was lower from the coagulation pond yet without coagulation process during March through August 1999. However, water samples taken from the pond after precipitation did not show similar results in radon level. (author)

  11. Standardised Radon Index (SRI: a normalisation of radon data-sets in terms of standard normal variables

    Directory of Open Access Journals (Sweden)

    R. G. M. Crockett

    2011-07-01

    Full Text Available During the second half of 2002, from late June to mid December, the University of Northampton Radon Research Group operated two continuous hourly-sampling radon detectors 2.25 km apart in the English East Midlands. This period included the Dudley earthquake (ML = 5, 22 September 2002 and also a smaller earthquake in the English Channel (ML = 3, 26 August 2002. Rolling/sliding windowed cross-correlation of the paired radon time-series revealed periods of simultaneous similar radon anomalies which occurred at the time of these earthquakes but at no other times during the overall radon monitoring period. Standardising the radon data in terms of probability of magnitude, analogous to the Standardised Precipitation Indices (SPIs used in drought modelling, which effectively equalises different non-linear responses, reveals that the dissimilar relative magnitudes of the anomalies are in fact closely equiprobabilistic. Such methods could help in identifying anomalous signals in radon – and other – time-series and in evaluating their statistical significance in terms of earthquake precursory behaviour.

  12. The new social marketing challenge to promote radon testing.

    Science.gov (United States)

    DiPofi, J A; LaTour, M S; Henthorne, T L

    2001-01-01

    As part of a project funded by the Environmental Protection Agency, exploratory qualitative analysis was conducted to gain insight into perceptions of the threat of radon in the Karst geological region (i.e., Northern Alabama, Central Tennessee, Central Kentucky). Based on health practitioner input, it was clear that the tenets of Protection Motivation Theory (PMT) and the probing afforded by focus group research would provide greatly needed theory-based insight into the public reactions (or lack thereof) to the threat posed by radon. Qualitative research findings of this project are discussed as well as preliminary recommendations are provided to advance the protection motivation theory research agenda for promoting awareness of the threat of radon and to influence appropriate response to that threat.

  13. Monitoring of the Syrian rift valley using radon technique

    International Nuclear Information System (INIS)

    Al-Hilal, M.; Al-Ali, A.; Jubeli, Y.

    1997-02-01

    Groundwater radon data were recorded once every two months from six monitoring sites of the Syrian rift valley during the year 1996. Radon samples were measured from deep artesian wells and from continuously-flowing springs that are distributed along this most active seismic zone in Syria. The available data were integrated with previously measured groundwater radon data from the same stations in order to estimate the range of normal radon fluctuations in the region. The estimation of such range may enable the separation between usual groundwater radon variations from other outliers which may indicate possible tectonic activities or earthquake hazards in the study area. Periodical radon measurements based on two months intervals and long distance between sampling stations does not enable us to trust with high level of confidence the connection between radon values and any possible earth dynamics. Therefore, shorter measuring time with closer monitoring sites are highly recommended to achieve the optimum advantage of such application. (Author). 8 Figs., 2 Tabs., 10 Refs

  14. Outdoor radon variation in Romania

    International Nuclear Information System (INIS)

    Simion, Elena; Simion, Florin

    2008-01-01

    Full text: The results of a long-term survey (1992 - 2006) of the variations of outdoor radon concentrations in semi-natural location from Romania are reported in the present paper. Measurements, covering between two and four sessions of the day (morning, afternoon, evening and night), were performed on a daily bases by 37 Environmental Radioactivity Monitoring Stations from National Environmental Radioactivity Survey Network. The method used was based on indirect determination of outdoor radon from aerosol samples collected on glass micro-fibre filters by drawing the air through the filters. The sampling was performed in a fixed place at a height of 2 m above the ground surface. Total beta counting of aerosol samples collected was performed immediately and after 20 hours. Values recorded during the years of continuous measurement indicated the presence of several patterns in the long-term variation of outdoor radon concentration: diurnal, seasonal and annual variation. For diurnal variation, outdoor radon concentration shows a maximum values in the night (early hours) and minimum values by day (in the afternoon). On average, this maximum is a factor of 2 higher than the minimum. Late autumn - beginning of winter maximum and an early spring minimum are characteristic for seasonal patterns. In the long term a seasonal pattern was observed for diurnal variation, with an average diurnal maximum to minimum ratio of 1.33 in winter compared with 3.0 in the summer months. The variations of outdoor radon levels showed little correlation with the uranium concentration of the ground and were attributed to changes in soil moisture content. In dry seasons, because of the low precipitation, the soil was drying out in the summer allowing fractures to develop and radon to migrate easily through the ground. Depending on micro-climatic and geological conditions, outdoor radon average concentrations in different regions of Romania are from 1200 mBq/mc to 13065 mBq/mc. The smallest

  15. A technical evaluation of the EDA radon gas continuous monitoring system

    International Nuclear Information System (INIS)

    Bigu, J.

    1979-04-01

    Extensive laboratory and underground tests were conducted with a radon gas continuous monitoring system built by EDA Instruments Inc. The system consists of several remote radon gas sensors linked via signal cables to a central control unit that fully controls the operation of the radon monitors. The system enables four operations to be performed: sampling, background, flush and bypass. The sequence and duration of these functions is programmable. Up to 20 functions in any desired pattern each lasting from 1 min to 23 hr 59 min can be programmed. Several programs were used during the experiments in order to obtain radon and thoron gas levels. The performance of the EDA system was quite satisfactory. It is suggested that ruggedization as well as some other modifications be introdouced into the system to: a) better withstand the harsh underground environment; and b) improve its performance

  16. Characterization of radon levels in indoor air

    International Nuclear Information System (INIS)

    George, A.C.

    1982-01-01

    The purpose is to describe the different types of monitoring and sampling techniques that can determine the radiation burden of the general public from radon and its decay products. This is accomplished by measuring the range and distribution of radon and radon decay products through broad surveys using simple and convenient integrating monitoring instruments. For in-depth studies of the behavior of radon decay products and calculation of the radiation dose to the lung, fewer and more intensive and complex measurements of the particle size distribution and respiratory deposition of the radon decay products are required. For diagnostic purposes, the paper describes measurement techniques of the sources and exhalation rate of radon and the air exchange inside buildings. Measurement results form several studies conducted in ordinary buildings in different geographical areas of the United States, using the described monitoring techniques, indicate that the occupants of these buildings are exposed to radon and radon decay product concentrations, varying by as much as a factor of 20

  17. Radon in streams and ground waters of Pennsylvania as a guide to uranium deposits

    International Nuclear Information System (INIS)

    Korner, L.A.; Rose, A.W.

    1977-06-01

    Radon-222, a daughter in the radioactive decay of uranium, has potential as a geochemical guide to uranium ores because of its chemical inertness and its relatively easy determination. The radon contents of 59 stream and 149 ground waters have been determined with a newly designed portable radon detector in order to test the method in uranium exploration. Radon contents of stream waters do not appear useful for reconnaissance uranium exploration of areas like Pennsylvania because of relatively rapid degassing of radon from turbulent waters, and because most radon is derived from nearby influx of ground waters into the streams. Radon in streams near uranium occurrences in Carbon and Lycoming counties is lower than many background streams. Radon in ground water is recommended as a reconnaissance method of uranium exploration because most samples from near mineralized areas are anomalous in radon. In contrast, uranium in ground waters is not anomalous near mineralized areas in Carbon County. Equations are derived to show the relation of radon in ground waters to uranium contents of enclosing rocks, emanation of radon from the solids to water, and porosity or fracture width. Limonites are found to be highly enriched in radium, the parent of radon. A model for detection of a nearby uranium ore body by radon measurement on a pumping well has been developed

  18. Benefits to a life insurance company from providing radon tests for clients

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1993-01-01

    If a life insurance company provided free radon tests to clients, clients' life expectancies would be extended and profits would thereby be increased. This effect is quantified and it is found that the direct monetary benefits to the company could be substantial. Several subsidiary advantages are also discussed

  19. Method for determination of radon-222 in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Suomela, J.

    1993-06-01

    The procedure for the determination of radon-222 by liquid scintillation counting is quite specific for this radionuclide. Radon-222 is extracted readily from the water sample by an organic scintillant. The decay products of radon-222 will remain in the water phase whilst radon-222 will be extracted into the organic phase. Before measurement the sample is stored for three hours until equilibrium is reached between radon-222 and its alpha emitting decay products. The alpha activity from radon-222 and its decay products is measured in a liquid scintillation counter

  20. Control of radon daughters in underground mining

    International Nuclear Information System (INIS)

    Swent, L.W.

    1983-01-01

    This paper discusses technical developments that may enable uranium mine operators to improve engineering controls of radon daughter concentrations in mines, and developments in regulatory controls. The origin of radon daughters in underground mines is explained. The procedure for sampling and determining the concentration of alpha radiation in sampled air is reviewed. The principal technical development in the last few years has been the perfection and use of a class of meters which determine radon daughter concentrations in an air sample in a matter of two or three minutes without any aging period. A number of underground uranium mine operators are now using ''instant'' type meters and the Mine Safety and Health Administration (MSHA) has approved their use in a number of mines. The difficulty experienced by uranium mine operators in complying with a MSHA regulation which requires that no person be exposed to radon daughter concentrations exceeding 1 Working Level (WL) in any active working place is discussed

  1. Study of a Greek area with enhanced indoor radon concentrations

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Koukouliou, V.; Kehagia, K.

    2003-01-01

    In this paper the focus is on Arnea Chalkidikis, an area in Greece with granitic geological background and indications of possible elevated radon concentration indoors. Data are reported of indoor radon measurements with etched track detectors and those used for dosimetric estimations. Moreover, data are reported on soil gas and soil radon concentrations in Arnea, as well as radon and uranium concentrations in water samples. From the measured radon concentrations in water samples the contribution to the overall dose has been calculated. For a period of 1 month, indoor radon and progeny activity has also been monitored in the dwelling that has the maximum indoor radon concentration in Greece. This dwelling is in Arnea and the dose delivered to the inhabitants has been calculated. Mean annual effective dose due to indoor radon was 4.5 mSv and about 11% of this was due to the use of water. Mean soil gas concentration and soil radon concentration were (90 ± 30) kBq m -3 (P -3 (P -1 (P<0.05). (author)

  2. Sign of Radon for locate geothermic sources

    International Nuclear Information System (INIS)

    Gonzalez Teran, D.

    1991-01-01

    Evaluation of a geothermic field is based upon geological, geophysical and geochemical studies that enable the evaluation of the deposit potential, that is to say, the amount of energy per unit mass, the volume of the trapped fluid, vapor fraction and fluid chemistry. This thesis has as its objective the evaluation of radon gas emanation in high potential geothermic zones in order to utilize the results as a low cost and easy to manage complimentary tool in geothermic source prospection. In chapter I the importance and evaluation of a geothermic deposit is discussed. In chapter II the general characteristics of radon are discussed: its radioactivity and behavior upon diffusion over the earth's surface> Chapter III establishes the approach used in the geothermic field of Los Azufres, Michoacan, to carry out samplings of radon and the laboratory techniques that were used to evaluate the concentration of radon in the subsoil. Finally in chapter IV measurements of radon in the field are compared to geological faults in the area under study. The sampling zones were: low geothermic potential zone of the northern and the southern zone having a greater geothermic potential than that in the north. The study was carried out at different sampling times using plastics detectors of from 30 to 46 days from February to July. From the results obtained we concluded that the emission of radon was greater in the zones of greatest geothermic potential than in the low geothermic potential zones it was also affected by the fault structure and the time of year in which sampling was done. (Author)

  3. Region III involvement in quality control and quality assurance of radon testing methods

    International Nuclear Information System (INIS)

    Coyle, F.T.

    1990-01-01

    Region III has set a goal of increasing the testing for radon by our residents. One approach to this goal, is to bolster the public's confidence in the testing laboratories. We believe that this can be done most effectively by assuring the quality of the measurements available to the public. All Proficient Laboratories and Pennsylvania Certified Laboratories have submitted a quality assurance (QA) program. A QA audit checklist has been developed which will be finalized and made available to the states in our Region. This paper deals with inspection, verification, and documentation of the various laboratories and their compliance with prudent measuring protocols and addresses the following items: Organization and responsibilities; Sampling procedures; Detector chain of custody; Measurement procedures, quality control checks; State certification and RMP; Data resection, validation, and reporting; Quality assurance reports to management; Interview and discussion of QA audit with responsible officer

  4. Measuring radon source magnitude in residential buildings

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Boegel, M.L.; Nero, A.V.

    1981-08-01

    A description is given of procedures used in residences for rapid grab-sample and time-dependent measurements of the air-exchange rate and radon concentration. The radon source magnitude is calculated from the results of simultaneous measurements of these parameters. Grab-sample measurements in three survey groups comprising 101 US houses showed the radon source magnitude to vary approximately log-normally with a geometric mean of 0.37 and a range of 0.01 to 6.0 pCi 1 -1 h -1 . Successive measurements in six houses in the northeastern United States showed considerable variability in source magnitude within a given house. In two of these houses the source magnitude showed a strong correlation with the air-exchange rate, suggesting that soil gas influx can be an important transport process for indoor radon

  5. Radon in Public Waterworks at the Cities of Pozega-Slavonia County

    International Nuclear Information System (INIS)

    Radolic, V.; Saric, I.; Miklavcic, I.

    2008-01-01

    At the end of year 2005, there was a sampling campaign of water samples from the public waterworks at the cities and municipalities of Pozega-Slavonia County. Number of measuring locations was defined by the number of inhabitants in each city or municipality with criterion of 1 location per 3000 inhabitants. Samples were taken from private wells as well, at those municipalities without public waterworks infrastructure. Radon measurements in water samples were performed by Alpha GUARD measuring system using standard procedure for quick measurements. The obtained values were in range of 3.5 to 35.9 Bq l -1 with arithmetic mean of 15.0 Bq l -1 and standard deviation of 8.2 Bq l -1 . These values are significantly lower than reference level of 100 Bq l -1 recommended by the European Commission; a concentration above this level warrants consideration of possible remedial action. Statistical t-test pointed out there is significant difference between average radon concentrations in water sampled from public supply and those from private wells. The estimation of annual effective dose received by an inhabitant of Pozega-Slavonia County from ingestion of water from public supply containing averaged 15.0 Bq l -1 of radon is 38 μSv/year. In addition, the annual effective dose due to inhalation of radon and its short lived daughters for the population of Pozega-Slavonia County is around 50 times greater (1.9 mSv/year) so as the risk for public health.(author)

  6. Testing and design of radon resisting membranes based on the experience from the Czech Republic

    International Nuclear Information System (INIS)

    Jiranek, M.

    2004-01-01

    Testing of barrier properties of insulating materials against radon is usually based on the measurement of the radon diffusion coefficient. Presented report summarizes results of radon diffusion coefficients measurements in more than 120 insulating materials obtained throughout Europe. All measurements were performed by the Czech Technical University, Faculty of Civil Engineering in cooperation with the Radiation Protection Institute. We have found out that great differences exist in diffusion properties, because the diffusion coefficients vary within eight orders from 10 -15 m 2 /s to 10 -8 m 2 /s. For each material category of different chemical composition statistical evaluation of results is presented. Possibilities of usage of the radon diffusion coefficient for the design of radon resisting membranes are discussed. Based on the experience from the Czech Republic the paper is trying to show that controlling applicability of membranes by setting of the upper limit for the radon diffusion coefficient is not a convenient approach. The main reason is that it is almost impossible to choose correctly one limit value for the whole Europe. The second reason is that a great number of common waterproofing materials have their radon diffusion coefficients above the probable limit value. As a consequence of this the protection against radon will be solved preferably by materials with Al foils, which is from the technical point of view meaningless, because membranes with Al foils have very low elongation and therefore they can very easily loose their barrier properties by destroying of the Al foil. The paper will show that it seems to be reasonable to replace strict limits by the real design of the insulation in dependence on particular building and soil characteristics. The design is proposed to be based on the calculation of the insulation thickness according to the formula: d ≥ l.arc sinh ((α 1 .l.λ.C S .(A f + A w ))/C dif .n.V)) (in m), where C S is the third

  7. The effect of sand/cement ratio on radon exhalation from cement specimens containing 226Ra

    International Nuclear Information System (INIS)

    Takriti, S.; Shweikani, R.; Ali, A. F.; Rajaa, G.

    2002-09-01

    Portland cement was mixed with different kind of sand (calcite and silica) in different ratio to produce radioactive specimens with radium chloride. The release of radon from these samples was studied. The results showed that radon release from the calcite-cement samples increased with the increases of the sand mixed ratio until fixed value (about 20%) then decreased to less than its release from the beginning, and the release changed with the sand size also. Radon release from silica-cement samples had the same observations of calcite-cement samples. It was found that calcite-cement reduced the radon exhalation quantity rather than the silica-cement samples. The decreases of the radon exhalation from the cement-sand may be due to the creation of free spaces in the samples, which gave the possibility to radon to decay into these free spaces rather than radon exhalation. The daughters of the radon decay 214 Bi and 214 Pb reported by gamma measurements of the cement-sand samples. (author)

  8. Metrology of the radon in air volume activity at the italian radon reference chamber

    Energy Technology Data Exchange (ETDEWEB)

    Sciocchetti, G.; Cotellessa, G.; Soldano, E.; Pagliari, M. [Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA Centro Ricerche Casaccia Roma (Italy)

    2006-07-01

    The approach of the Italian National Institute of Ionising Radiations (I.N.M.R.I.-ENEA) on radon metrology has been based on a complete and integrated system which can be used to calibrate the main types of {sup 222}Rn in air measuring instruments with international traceability. The Italian radon reference chamber is a research and calibration facility developed at the Casaccia Research Center in Roma. This facility has an inner volume of one m{sup 3}. The wall is a cylindrical stainless steel vessel coupled with an automated climate apparatus operated both at steady and dynamic conditions. The control and data acquisition equipment is based on Radotron system, developed to automate the multitasking management of different sets of radon monitors and climatic sensors. A novel approach for testing passive radon monitors with an alpha track detector exposure standard has been developed. It is based on the direct measurement of radon exposure with a set of passive integrating monitors based on the new ENEA piston radon exposure meter. This paper describes the methodological approach on radon metrology, the status-of-art of experimental apparatus and the standardization procedures. (authors)

  9. Metrology of the radon in air volume activity at the italian radon reference chamber

    International Nuclear Information System (INIS)

    Sciocchetti, G.; Cotellessa, G.; Soldano, E.; Pagliari, M.

    2006-01-01

    The approach of the Italian National Institute of Ionising Radiations (I.N.M.R.I.-ENEA) on radon metrology has been based on a complete and integrated system which can be used to calibrate the main types of 222 Rn in air measuring instruments with international traceability. The Italian radon reference chamber is a research and calibration facility developed at the Casaccia Research Center in Roma. This facility has an inner volume of one m 3 . The wall is a cylindrical stainless steel vessel coupled with an automated climate apparatus operated both at steady and dynamic conditions. The control and data acquisition equipment is based on Radotron system, developed to automate the multitasking management of different sets of radon monitors and climatic sensors. A novel approach for testing passive radon monitors with an alpha track detector exposure standard has been developed. It is based on the direct measurement of radon exposure with a set of passive integrating monitors based on the new ENEA piston radon exposure meter. This paper describes the methodological approach on radon metrology, the status-of-art of experimental apparatus and the standardization procedures. (authors)

  10. Measurements of radon in soil gas

    International Nuclear Information System (INIS)

    Paschuk, Sergei A.; Correa, Janine Nicolosi; Schelin, Hugo R.; Barbosa, Laercio; Sadula, Tatyana; Matsuzaki, Cristiana A.

    2009-01-01

    .03 L/min and the measurements were performed during 90 min approximately. Collected average levels of 222 Rn concentration were processed taking into account the internal volume of Soil Probe and connection vessels. Radon sampling was performed at a depth of 50 - 70 cm. Obtained experimental data of radon concentration present rather big variation but correlates perfectly with previously obtained results for 222 Rn activity in drinking water. Further measurements are planned to be performed at other regions of Parana State and will involve the mineral analysis of soil samples. (author)

  11. Results of the radon concentration survey in Sibiu county underground water

    International Nuclear Information System (INIS)

    Chicea, Dan; Cosma, Constantin

    2002-01-01

    In November 2000 a survey of radon ( 222 Rn) concentration in Sibiu county underground water was conducted. The radon concentration was measured with a A LUK 3A. The radon gas was extracted from water using the LUK VR device that works with LUK 3A. All samples were taken in 0.5 l recipients that were filled and sealed. Samples from eighteen cities and villages were taken. Special care was taken for the samples to be carefully brought to room temperature and not to be agitated or stirred before measuring the radon concentration. In measuring the radon concentration corrections like the solubility coefficient variation with temperature, the radon concentration increase in air in time and the background correction were applied. Results reveal that the underground water radon concentration is bigger in wells located in mountainous area, has an average value in wells from hilly region and is considerable lower in wells located in plain area. Another thing we noticed is that the samples taken from the city water pipe system present lower radon concentration values than the samples taken from home drilled wells. The minimum radon concentration value was found in the drinking water of Sibiu city, 1.6 Bq/l and in Sadu village, 1.965 Bq/l. The highest measured values are 28.1 Bq/l in Rasinari, a village located at the bottom of the mountains and 26.4 Bq/l, in Sibiel, a village 30 km away from the first one. These results reveal that the radon concentration values measured in Sibiu county are comparable with the measured values reported in literature and well below the maximum acceptable values. (authors)

  12. Comparative Study of Radon Concentration with Two Techniques and Elemental Analysis in Drinking Water Samples of the Jammu District, Jammu and Kashmir, India.

    Science.gov (United States)

    Kumar, Ajay; Kaur, Manpreet; Mehra, Rohit; Sharma, Dinesh Kumar; Mishra, Rosaline

    2017-10-01

    The level of radon concentration has been assessed using the Advanced SMART RnDuo technique in 30 drinking water samples from Jammu district, Jammu and Kashmir, India. The water samples were collected from wells, hand pumps, submersible pumps, and stored waters. The randomly obtained 14 values of radon concentration in water sources using the SMART RnDuo technique have been compared and cross checked by a RAD7 device. A good positive correlation (R = 0.88) has been observed between the two techniques. The overall value of radon concentration in various water sources has ranged from 2.45 to 18.43 Bq L, with a mean value of 8.24 ± 4.04 Bq L, and it agreed well with the recommended limit suggested by the European Commission and UNSCEAR. However, the higher activity of mean radon concentration was found in groundwater drawn from well, hand and submersible pumps as compared to stored water. The total annual effective dose due to radon inhalation and ingestion ranged from 6.69 to 50.31 μSv y with a mean value of 22.48 ± 11.03 μSv y. The total annual effective dose was found to lie within the safe limit (100 μSv y) suggested by WHO. Heavy metal analysis was also carried out in various water sources by using an atomic absorption spectrophotometer (AAS), and the highest value of heavy metals was found mostly in groundwater samples. The obtained results were compared with Indian and International organizations like WHO and the EU Council. Among all the samples, the elemental analysis is not on the exceeding side of the permissible limit.

  13. Radon Concentrations in Drinking Water in Beijing City, China and Contribution to Radiation Dose

    Science.gov (United States)

    Wu, Yun-Yun; Ma, Yong-Zhong; Cui, Hong-Xing; Liu, Jian-Xiang; Sun, Ya-Ru; Shang, Bing; Su, Xu

    2014-01-01

    222Rn concentrations in drinking water samples from Beijing City, China, were determined based on a simple method for the continuous monitoring of radon using a radon-in-air monitor coupled to an air-water exchanger. A total of 89 water samples were sampled and analyzed for their 222Rn content. The observed radon levels ranged from detection limit up to 49 Bq/L. The calculated arithmetic and geometric means of radon concentrations in all measured samples were equal to 5.87 and 4.63 Bq/L, respectively. The average annual effective dose from ingestion of radon in drinking water was 2.78 μSv, and that of inhalation of water-borne radon was 28.5 μSv. It is concluded that it is not the ingestion of waterborne radon, but inhalation of the radon escaping from water that is a substantial part of the radiological hazard. Radon in water is a big concern for public health, especially for consumers who directly use well water with very high radon concentration. PMID:25350007

  14. Radon Concentrations in Drinking Water in Beijing City, China and Contribution to Radiation Dose

    Directory of Open Access Journals (Sweden)

    Yun-Yun Wu

    2014-10-01

    Full Text Available 222Rn concentrations in drinking water samples from Beijing City, China, were determined based on a simple method for the continuous monitoring of radon using a radon-in-air monitor coupled to an air-water exchanger. A total of 89 water samples were sampled and analyzed for their 222Rn content. The observed radon levels ranged from detection limit up to 49 Bq/L. The calculated arithmetic and geometric means of radon concentrations in all measured samples were equal to 5.87 and 4.63 Bq/L, respectively. The average annual effective dose from ingestion of radon in drinking water was 2.78 μSv, and that of inhalation of water-borne radon was 28.5 μSv. It is concluded that it is not the ingestion of waterborne radon, but inhalation of the radon escaping from water that is a substantial part of the radiological hazard. Radon in water is a big concern for public health, especially for consumers who directly use well water with very high radon concentration.

  15. Instrumentation for collecting and measuring radon and its daughters

    International Nuclear Information System (INIS)

    Essling, M.A.; Hengde, W.; Markun, F.; Toohey, R.E.; Rundo, J.; Miranda, J.E. Jr.

    1982-01-01

    A new sampling can is described for collecting an air sample for determination of its radon content. Instruments which are employed for the continuous monitoring of radon or its daughters in houses are described and their performances discussed

  16. Source and distribution of radon-222 and radium-226 within South Atlantic Bight waters

    International Nuclear Information System (INIS)

    Ramsey, E.

    1982-09-01

    Radon and radium concentrations were measured in South Atlantic Bight (SAB) waters during six weeks in the summer of 1981. Sampling was designed to coincide with subsurface intrusions of cold Gulf Stream water onto the continental shelf and was part of a large study of the SAB. The distinct zonation of sediment types within the SAB offered the possibility to use radon to trace advection of intruded bottom water. It was determined that the bottom excess radon concentrations, calculated from radon and radium data, were distributed into three groups. The first group of concentrations ranged from 320 to 732 dpm/100L (n=3) and was associated with water occupying the nearshore zone. The second set was sampled within intruded water in the midshelf region. These values ranged from 25.5 to 151.5 dpm/100L (n=35). The third range describes radon concentrations contained in water that is a potential source of upwelled Gulf Stream water. These shelf break concentrations ranged from -1.0 to 213.0 dpm/100L (n=13), and were found to differ significantly (P < 0.001) from the midshelf range of radon concentrations (Mann-Whitney test). The division of radon concentrations into three distinct zones within the SAB waters may provide an indicator of shelf and Gulf Stream water interactions. 55 references, 24 figures, 4 tables

  17. Biological effects of radon in Drosophila; Efectos biologicos del radon en Drosophila

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel P, A E; Tavera D, L; Cruces M, M P; Arceo M, C; Rosa D, M.E. de la

    1992-04-15

    The main objective of this investigation, is to study the biological effects of the Radon-222 at low dose in 'Drosophila melanogaster'. It is necessary to mention that these effects will analyze from the genetic point of view for: 1) To evaluate in which form the Radon-222 to low dose it influences in some genetic components of the adaptation in Drosophila, such as: fecundity, viability egg-adult and sex proportion. 2) To evaluate which is the genetic effect that induces the Radon to low dose by means of the SMART technique in Drosophila melanogaster, and this way to try of to identify which is the possible mechanism that causes the genetic damage to somatic level. The carried out investigation was divided in three stages: 1. Tests to the vacuum resistance. 2. Test of somatic mutation, and 3. Determination of the presence of radon daughters on the adult of Drosophila. It is necessary to point out that all the experiments were made by triplicate and in each one of them was placed detectors in preset places. Those obtained results are presented inside the 4 charts included in the present work. (Author)

  18. Biological effects of radon in Drosophila; Efectos biologicos del radon en Drosophila

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel P, A.E.; Tavera D, L.; Cruces M, M.P.; Arceo M, C.; Rosa D, M.E. de la

    1992-04-15

    The main objective of this investigation, is to study the biological effects of the Radon-222 at low dose in 'Drosophila melanogaster'. It is necessary to mention that these effects will analyze from the genetic point of view for: 1) To evaluate in which form the Radon-222 to low dose it influences in some genetic components of the adaptation in Drosophila, such as: fecundity, viability egg-adult and sex proportion. 2) To evaluate which is the genetic effect that induces the Radon to low dose by means of the SMART technique in Drosophila melanogaster, and this way to try of to identify which is the possible mechanism that causes the genetic damage to somatic level. The carried out investigation was divided in three stages: 1. Tests to the vacuum resistance. 2. Test of somatic mutation, and 3. Determination of the presence of radon daughters on the adult of Drosophila. It is necessary to point out that all the experiments were made by triplicate and in each one of them was placed detectors in preset places. Those obtained results are presented inside the 4 charts included in the present work. (Author)

  19. Radon exhalation rate on the Sivrice (Elazig ) fault zone

    International Nuclear Information System (INIS)

    Sahin, S.; Kuluoeztuerk, M. F.; Dogru, M.

    2009-01-01

    Four radon monitoring stations were built on the Sivrice Fault Zone which is a part of the East Anatolian Fault System that one of the very important two fault systems which tends to produce earthquake in Turkey. Radon exhalation rate were analyzed in the soil and water samples which collected around the stations. Radon exhalation rate in the soil and water samples were determined by using CR-39 that it is plastic detector.

  20. Biological radiation effects of Radon in Drosophila; Efectos biologicos del radon en Drosophila

    Energy Technology Data Exchange (ETDEWEB)

    Pimentel P, A E

    1996-12-31

    In order to contribute to the knowledge on the effects of radon and its decay products, the aim of this investigation is to study the biological effects of radon using Drosophila melanogaster throught the somatic mutation and recombination test (SMART) and the analysis of some adaptative factors exposing larvaes to controlled radon atmosphers, considering that this insect could be used as biological monitor. Using the somatic mutation test a mutagenic effect was observed proportional to radon concentration, into an interval of 1 {+-} 0.3 to 111 {+-} 7.4 KBq/m{sup 3} equivalent to doses under 0.0106 Gy. The correlation analysis gives a linear (r=0.80) relationship with a positive slope of 0.2217. The same happens when gamma rays are used in the interval of 1 to 20 Gy, given a linear dose-dependent effect (r=0.878) is obtained; nevetheless the slop is smaller (m=0.003) than for radon. Analysing the results of adaptative factors of the nine exposed generations, it was found that probably radon exposition induced dominant lethals during gametogenesis or/and a selection of the more component gamets of the treated individuals in larval state. It was reflected in the significant decrease on fecundity of the generation exposed. Nevertheless the laying eggs had an increase in egg-to-adult viability and the develop velocity was higher than in control for 3 KBq/m{sup 3}, this suggest that radon concentrations used were able to induce repair mechanisms. These data agree with the Hormesis hypothesis that says: low doses have positive effects on health. It was not possible to obtain a dose-effect relationship except with the develop velocity where it was found a dose-effect inverse proportion. In conclusion, Drosophila melanogaster could be a good system to obtain in vivo damaged induction concentration dependent of radon and its decay products, as well as to study the effects in an exposed population by the analysis of adaptative factors. (Author).

  1. Study on the influence factors about the soil radon measurement

    International Nuclear Information System (INIS)

    Wu Zixiang; Liu Yanbin; Jia Yuxin; Mai Weiji; Liu Xiaolian; Yang Yuhua

    2006-01-01

    Objective: To explore relevant factors about the soil radon measurement and provide gist of formulating correct measure method by studying the way of the soil radon measurement. Methods: Deflation-ionization room standard is adopted. Results: The concentration of soil radon becomes higher with the sample's volume added, it also augmented with the measure depth increased in certain degree; The concentration of soil radon changes little when sample's depth is above 60 cm; The time of deflation has no obvious influence on the concentration of soil radon, but microwave show serious effect on it; The results will be lowered when the desiccant is humidified, raining has the same affection on it; Plant has some impact on it. Conclusion: The measured results will be affected by microwave, oscillate and plant. Sample's volume and depth, soil's humidity can influence it too. The result's veracity can be guaranteed by choosing appropriate sample and measure condition. (authors)

  2. Construction materials and Radon

    International Nuclear Information System (INIS)

    Paschuk, Sergei A.; Correa, Janine Nicolosi; Loriane, Fior; Schelin, Hugo R.; Pottker, Fabiana; Paula Melo, Vicente de

    2008-01-01

    Full text: Current studies have been performed with the aim to find the correlation of radon concentration in the air and used construction materials. At the first stage of the measurements different samples of materials used in civil construction were studied as a source of radon in the air and at the second step it was studied the radon infiltration insulation using different samples of finishing materials. For 222 Rn concentration measurements related to different construction materials as well as for the studies of radon emanation and its reduction, the sealed cell chambers, of approximately 60 x 60cm 2 , have been built using the ceramic and concrete blocks. This construction has been performed within protected and isolated laboratory environment to maintain the air humidity and temperature stable. These long term measurements have been performed using polycarbonate alpha track passive detectors. The exposure time was set about 15 days considering previous calibration performed at the Institute of Radiation Protection and Dosimetry (IRD/CNEN), where the efficiency of 70% was obtained for the density of alpha particle tracks about 13.8 cm -2 per exposure day and per kBq/m 3 of radon activity concentration. The chemical development of alpha tracks has been achieved by electrochemical etching. The track identification and counting have been done using a code based on the MATLAB Image Processing Toolbox. The cell chambers have been built following four principle steps: 1) Assembling the walls using the blocks and mortar; 2) Plaster installation; 3) Wall surface finishing using the lime; 4) Wall surface insulation by paint. Making the comparison between three layers installed at the masonry walls from concrete and ceramic blocks, it could be concluded that only wall painting with acrylic varnish attended the expectation and reduced the radon emanation flow by the factor of 2.5 approximately. Studied construction materials have been submitted the instant

  3. National survey of indoor radon levels in Croatia

    International Nuclear Information System (INIS)

    Radolic, V.; Vukovic, B.; Stanic, D.; Katic, M.; Faj, Z.; Lukacevic, I.; Planinic, J.; Suveljak, B.; Faj, D.; Lukic, M.

    2006-01-01

    National survey of indoor radon was performed by a random sampling of thousand (782 realized) dwellings in Croatia. Radon concentrations were measured for one year with LR-115 SSNT detectors and arithmetic and geometric means of 68 and 50 Bq/m 3 were obtained, respectively. The arithmetic means of radon concentrations on 20 counties were from 33 to 198 Bq/m 3 . The percentage of dwellings with radon concentrations above 200 and 400 Bq/m 3 was 5.4% and 1.8%, respectively. The average annual effective dose of the indoor radon was estimated as 2.2 mSv. (author)

  4. Radon programme in the Czech Republic

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.

    2003-01-01

    The framework of the Radon programme in the Czech republic includes both precautionary measures and interventions. The programme informally started in early eighties has been now incorporated in national legislation (Atomic Act, Radiation Protection Decree, etc.). Aim of precautionary measures is to avert construction of building above natural radiation guidance levels (200 Bq/m 3 for indoor radon concentration and 0.5 Sv/h for gamma dose rate) by protection of new buildings against soil radon ingress, by regulation of natural radioactivity in building materials and supplied water. Aim of interventions is to identify buildings affected by enhanced natural radioactivity and help owners to put into effect reasonable remedial measures. Two sets of intervention levels for indoor natural exposure were established: guidance intervention levels 400 Bq/m 3 (indoor radon), 1.0 Sv/h (indoor gamma dose rate) and limit values 4000 Bq/m 3 and 10 Sv/h. The radon programme is based both on governmental and private activities. The governmental activities include representative and targeted indoor radon survey, subsidy for radon mitigation, mitigation test measurements and public information on radon issue. The private activities include radon measurement (radon index of building site, indoor measurements, radon diagnosis) and remedial measures. More than 100 commercial companies were authorised by Radiation Protection Authority (SUJB) to provide these measurements

  5. Intercomparison and intercalibration of passive/active radon and active radon progeny instruments and methods in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng W.

    1993-06-01

    An intercomparison and intercalibration exercise for radon and radon progeny measurements made with active and passive instruments was held at EML from October 22--30,1992. Twenty-five participants submitted 96 passive integrating devices, eight active devices for radon, and seven integrating devices for potential alpha energy concentration (PAEC). In addition, 40 grab samples for radon progeny analysis were taken by five groups that participated in person during the intercomparison. The results reported to EML indicate that the majority of the participants (70%) obtained mean results within 10% of the EML reference value. Although the instruments used in this exercise are based on different principles of collection and detection, they all appear reliable. However, in some instances there seemed to be some minor problems with quality control and calibration bias. Also, the large counting errors for the PAEC experienced by some of the participants can be minimized by using higher sampling air flow rates without sacrificing instrument portability

  6. Variability in the exhalation rate of radon

    International Nuclear Information System (INIS)

    Rundo, J.; Markun, F.; Sha, J.Y.; Cameron, P.

    1976-01-01

    In a day-long study, twenty-eight 10-min samples of breath were collected from a former radium dial painter and were analyzed for radon. The radon exhalation rate showed good short-term reproducibility, but there was a dramatic short-lived increase in the first samples collected after lunch and a slow but steady increase during the course of the day

  7. Radon

    Science.gov (United States)

    ... radon-resistant features. These features include gravel and plastic sheeting below the foundation, along with proper sealing ... lower the radon level. Detailed information about radon reduction in your home or building can be found ...

  8. Radon and radon daughters indoors, problems in the determination of the annual average

    International Nuclear Information System (INIS)

    Swedjemark, G.A.

    1984-01-01

    The annual average of the concentration of radon and radon daughters in indoor air is required both in studies such as determining the collective dose to a population and at comparing with limits. Measurements are often carried out during a time period shorter than a year for practical reasons. Methods for estimating the uncertainties due to temporal variations in an annual average calculated from measurements carried out during various lengths of the sampling periods. These methods have been applied to the results from long-term measurements of radon-222 in a few houses. The possibilities to use correction factors in order to get a more adequate annual average have also been studied and some examples have been given. (orig.)

  9. Factors influencing radon attenuation by tailing covers

    International Nuclear Information System (INIS)

    Silker, W.B.; Rogers, V.C.

    1981-07-01

    The US NRC, in its Generic Environmental Impact Statement on uranium milling has specified that the radon flux escaping a uranium mill tailings pile will be reduced to pCi/m 2 s by application of covering layers of soils and clays. These covers present a radon diffusion barrier, which sufficiently increases the time required for radon passage from the tailings to the atmosphere to allow for decay of 222 Rn within the cover. The depth of cover necessary to reduce the escaping radon flux to the prescribed level is to be determined by calculation, and requires precise knowledge of the radon diffusion coefficient in the covering media. A Radon Attenuation Test Facility was developed to determine rates of radon diffusion through candidate cover materials. This paper describes this facility and its application for determining the influence of physical properties of the soil column on the radon diffusion coefficient

  10. Smoking cessation programmes in radon affected areas: can they make a significant contribution to reducing radon-induced lung cancers?

    International Nuclear Information System (INIS)

    Denman, A.R.; Groves-Kirkby, C.J.; Timson, K.; Shield, G.; Rogers, S.; Phillips, P.S.

    2008-01-01

    Domestic radon levels in parts of the UK are sufficiently high to increase the risk of lung cancer in the occupants. Public health campaigns in Northamptonshire, a designated radon affected area with 6.3% of homes having average radon levels over the UK action level of 200 Bq m -3 , have encouraged householders to test for radon and then to carry out remediation in their homes, but have been only partially successful. Only 40% of Northamptonshire houses have been tested, and only 15% of householders finding raised levels proceed to remediate. Of those who did remediate, only 9% smoked, compared to a countywide average of 28.8%. This is unfortunate, since radon and smoking combine to place the individual at higher risk by a factor of around 4, and suggests that current strategies to reduce domestic radon exposure are not reaching those most at risk. During 2004-5, the NHS Stop Smoking Services in Northamptonshire assisted 2,808 smokers to quit to the 4-week stage, with some 30% of 4-week quitters remaining quitters at 1 year. We consider whether smoking cessation campaigns make significant contributions to radon risk reduction on their own, by assessing individual occupants' risk of developing lung cancer from knowledge of their age, gender, and smoking habits, together with he radon level in their house. The results demonstrate that smoking cessation programmes have significant added value in radon affected areas, and contribute a greater health benefit than reducing radon levels in the smokers' homes, whilst they remain smokers. Additionally, results are presented from a questionnaire-based survey of quitters, addressing their reasons for seeking help in quitting smoking, and whether knowledge of radon risks influenced this decision. The impact of these findings on future public health campaigns to reduce the impact of radon and smoking are discussed. (author)

  11. The radon

    International Nuclear Information System (INIS)

    1998-01-01

    This booklet is intended to answer briefly the most important questions about the nature and sources of radon, its pathways from environment to organism, as well as the ways to minimize its concentration in the habitat's atmosphere. The radon is a naturally appearing radioactive gas, produced through the decay of uranium and radium present in the terrestrial crust. It can be found everywhere on the planet's surface and it is emitted particularly from the granite and volcanic underground rocks as well as from certain construction materials. It is one of the agents producing pulmonary cancer, although not so dangerous as the tobacco is. The following items are elaborated in this booklet: - the place of radon in the average exposure to ionizing radiations of the French population; - the risk; - the radon in the environment (the meteorological conditions, the nature of the rocks); - radon in dwellings (radon measurements in the French dwellings, the entrance pathways of radon, the dependence of radon concentration on the profession and way of life of the inhabitants); - radon measurements; - how to reduce the radon concentration in dwellings

  12. A law of removing radon by ventilation and air requirement calculation for eliminating radon daughters in uranium mines

    International Nuclear Information System (INIS)

    Wu Gang

    1988-06-01

    In accordance with testing data of removing radon and its daughters by ventilation from shrinkage and filling stopes of uranium mines, a law of removing radon by ventilation from the stopes is analyzed and summed. According to the decay law of radon and its daughters, an accumulation equation of potential alpha energy from radon daughters is presented with hyperbolic regression equation. the calculating formulae of ventilation flow are derived from the accumulation equation for eliminating radon daughters in inlet flow with or without contamination. It has been proved that the amount of ventilation air calcuated could meet the requirements of radiation safety rationally and economically

  13. Radon dynamics in underwater thermal radon therapy

    International Nuclear Information System (INIS)

    Lettner, H.; Hofmann, W.; Winkler, R.; Rolle, R.; Foisner, W.

    1998-01-01

    At a facility for underwater thermal radon therapy in Bad Hofgastein, experiments were carried out with the aim of establishing radon in the air exhaled by the treated patients and of radon decay products on the skin of the patients. The time course of radon concentration in the exhaled air shows a maximum a few minutes after entering the bath, then the Rn concentration remains constant over the remaining time spent in the bath. Taking into account several simplifying assumptions, the average dose to the epidermis from radon daughters is about 50 μGy. (A.K.)

  14. Radon exhalation of cementitious materials made with coal fly ash: Part 1 - scientific background and testing of the cement and fly ash emanation

    International Nuclear Information System (INIS)

    Kovler, K.; Perevalov, A.; Steiner, V.; Metzger, L.A.

    2005-01-01

    Increased interest in measuring radionuclides and radon concentrations in fly ash, cement and other components of building products is due to the concern of health hazards of naturally occurring radioactive materials (NORM). The current work focuses on studying the influence of fly ash (FA) on radon-exhalation rate (radon flux) from cementitious materials. The tests were carried out on cement paste specimens with different FA contents. The first part of the paper presents the scientific background and describes the experiments, which we designed for testing the radon emanation of the raw materials used in the preparation of the cement-FA pastes. It is found that despite the higher 226 Ra content in FA (more than 3 times, compared with Portland cement) the radon emanation is significantly lower in FA (7.65% for cement vs. 0.52% only for FA)

  15. Measurements of radon concentrations in a sample representative of housing in Franche-Comte

    International Nuclear Information System (INIS)

    Aury, K.; Clinard, F.; Tillier, C.; Catelinois, O.; Pirard, P.; Aury, K.; Nourry, L.; Hochart, A.

    2008-01-01

    Three departments on four ones in Franche-Comte are classified at risk for radon: measurements are so compulsory in establishments receiving public. For the residential sector, no obligation of measurement are compulsory when french people spend 70% of their time in it. The data concerning homes are fragmentary and deserve to be completed. This campaign of measurements has confirmed the existence of radon in relatively high concentrations in Franche-Comte, including the sedimentary areas, justifying the necessity to realize a precise evaluation of the sanitary impact. The model will allow to study different strategies to reduce radon in houses. (N.C.)

  16. Radon in Schools

    Science.gov (United States)

    ... Search Search Radon Contact Us Share Radon in Schools Related Information Managing Radon in Schools Radon Measurement ... Radon Could Be a Serious Threat to Your School Chances are you've already heard of radon - ...

  17. Radon concentration distributions in shallow and deep groundwater around the Tachikawa fault zone.

    Science.gov (United States)

    Tsunomori, Fumiaki; Shimodate, Tomoya; Ide, Tomoki; Tanaka, Hidemi

    2017-06-01

    Groundwater radon concentrations around the Tachikawa fault zone were surveyed. The radon concentrations in shallow groundwater samples around the Tachikawa fault segment are comparable to previous studies. The characteristics of the radon concentrations on both sides of the segment are considered to have changed in response to the decrease in groundwater recharge caused by urbanization on the eastern side of the segment. The radon concentrations in deep groundwater samples collected around the Naguri and the Tachikawa fault segments are the same as those of shallow groundwater samples. However, the radon concentrations in deep groundwater samples collected from the bedrock beside the Naguri and Tachikawa fault segments are markedly higher than the radon concentrations expected from the geology on the Kanto plane. This disparity can be explained by the development of fracture zones spreading on both sides of the two segments. The radon concentration distribution for deep groundwater samples from the Naguri and the Tachikawa fault segments suggests that a fault exists even at the southern part of the Tachikawa fault line. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Radon/radium detection increases uranium drilling effectiveness

    International Nuclear Information System (INIS)

    Morse, R.H.; Cook, L.M.

    1979-01-01

    The use of portable radon detectors has become routine in reconnaissance uranium surveys where water and sediment samples are analyzed in field labs for radon and radium, and in detailed work where drill hole locations are pinpointed by field determinations of radon in soil gas from shallow holes. During the drilling program itself, however, very few operators are taking advantage of radon and radium analyses to decide whether a barren drill hole was a near miss or whether the immediate area can be written off. The technique, which is outlined here, is effective both above and below the water table

  19. The reduction of radon hazard in smoke-free working environments

    International Nuclear Information System (INIS)

    Yu, K.N.; Young, E.C.M.; Guan, Z.J.; Liu, X.W.

    1996-01-01

    The variations in a number of properties related to radon as a result of the presence of cigarette smoke have been investigated in an unventilated room. These properties include the radon concentration, the total potential alpha energy concentration of radon daughters, the equilibrium factor and the fraction of unattached radon daughters. From the data collected, a sample calculation of the reduction of the radon dose in smoke-free working environments has been carried out. (Author)

  20. Radon-technical design methods based on radon classification of the soil

    International Nuclear Information System (INIS)

    Kettunen, A.V.

    1993-01-01

    Radon-technical classification of the foundation soil divides the foundation soil into four classes: negligible, normal, high and very high. Separate radon-technical designing methods and radon-technical solutions have been developed for each class. On regions of negligible class, no specific radon-technical designing methods are needed. On regions of normal radon class, there is no need for actual radon-technical designing based on calculations, whereas existing radon-technical solutions can be used. On regions of high and very high radon class, a separate radon-technical designing should be performed in each case, where radon-technical solutions are designed so that expected value for indoor radon content is lower than the maximum allowable radon content. (orig.). (3 refs., 2 figs., 2 tabs.)

  1. Radon in houses due to radon in potable water

    International Nuclear Information System (INIS)

    Hess, C.T.; Korsah, J.K.; Einloth, C.J.

    1987-01-01

    Radon concentration in the air of 10 houses has been measured as a function of water use and meterological parameters such as barometric pressure, wind velocity and direction, indoor and outdoor temperature, and rainfall. Results of calibrations and data collected in winter, spring, fall, and summer are given for selected houses. Average values of radon concentration in air are from 0.80 to 77 rhoCi/1. Water use average ranges from 70 to 240 gal/day. Average potential alpha energy concentrations in these houses range from 0.02 to 1.6 working levels. The radon level due to water use ranges from 0 to 36% of the house radon from soil and water combined. The radon level change due to use of a filter on the water supply shows a 60% reduction in radon in the house. Conclusions are that water radon can be a major fraction of the radon in houses. The ratio of airborne radon concentration due to water use to the radon concentration in water is 4.5 x 10/sup -5/ - 13 x 10/sup -5/

  2. A complete low cost radon detection system

    International Nuclear Information System (INIS)

    Bayrak, A.; Barlas, E.; Emirhan, E.; Kutlu, Ç.; Ozben, C.S.

    2013-01-01

    Monitoring the 222 Rn activity through the 1200 km long Northern Anatolian fault line, for the purpose of earthquake precursory, requires large number of cost effective radon detectors. We have designed, produced and successfully tested a low cost radon detection system (a radon monitor). In the detector circuit of this monitor, First Sensor PS100-7-CER-2 windowless PIN photodiode and a custom made transempedence/shaping amplifier were used. In order to collect the naturally ionized radon progeny to the surface of the PIN photodiode, a potential of 3500 V was applied between the conductive hemi-spherical shell and the PIN photodiode. In addition to the count rate of the radon progeny, absolute pressure, humidity and temperature were logged during the measurements. A GSM modem was integrated to the system for transferring the measurements from the remote locations to the data process center. - Author-Highlights: • Low cost radon detection. • Integrated GSM modem for early warning of radon anomalies. • Radon detection in environment

  3. A brief overview on radon measurements in drinking water.

    Science.gov (United States)

    Jobbágy, Viktor; Altzitzoglou, Timotheos; Malo, Petya; Tanner, Vesa; Hult, Mikael

    2017-07-01

    The aim of this paper is to present information about currently used standard and routine methods for radon analysis in drinking waters. An overview is given about the current situation and the performance of different measurement methods based on literature data. The following parameters are compared and discussed: initial sample volume and sample preparation, detection systems, minimum detectable activity, counting efficiency, interferences, measurement uncertainty, sample capacity and overall turnaround time. Moreover, the parametric levels for radon in drinking water from the different legislations and directives/guidelines on radon are presented. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Current development of radon and radium monitoring at the Federal University of Technology (UTFPR)

    Energy Technology Data Exchange (ETDEWEB)

    Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Claro, Flavia Del; Perna, Allan F.N.; Reque, Marilson; Levchuk, Leonid, E-mail: sergei@utfpr.edu.br, E-mail: janine_nicolosi@hotmail.com, E-mail: flavia_delclaro@yahoo.com.br [Universidade Federal Tecnologica do Parana (UTFPR), Curitiba, PR (Brazil); Denyak, Valeriy; Schelin, Hugo R. [Instituto de Pesquisa Pele Pequeno Principe, Curitiba, PR (Brazil); Rocha, Zildete; Santos, Talita O., E-mail: rochaz@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    The present work describes the principal results concerning the radon and radium measurements at Curitiba (PR) urban area during the last decade. The monitoring was performed in cooperation with the Center of Nuclear Technology Development (CDTN/CNEN). For radon in air activity measurements, it was used polycarbonate etched track detectors such as LEXAN and CR-39, mounted in diffusion chambers. For soil gas measurements, the experimental setup was based on the Professional AlphaGUARD Radon Monitor connected to the Soil Gas Probe, filter vessels and air pump (AlphaPUMP), following the recommended protocols elaborated in the Soil-Gas Radon Intercomparison Measurements performed at different Countries of the world. In the case of radon tests in drinking water, the experimental setup was based on the AlphaGUARD Radon monitor and Electronic Radon Detector RAD7 connected to a special kit of glass vessels through the air pump. The obtained results permitted to identify few dwellings where radon concentration in air was found bigger than 600 Bq/m{sup 3}, that is considered as the action level by most of the European Community and the World Health Organization (WHO). In the case of well water, collected samples presented the average Rn-222 activity of about 60 Bq/L, that is 6 times bigger than the maximum level recommended by USEPA. Some artesian wells presented radon activity of almost 200 Bq/L. More over, almost all water samples presented the radioactivity of radium (Ra-226) salts bigger than the upper limit for global alpha radioactivity of potable water established by the Norms and Regulation of the Brazilian Ministry of Health. (author)

  5. Current development of radon and radium monitoring at the Federal University of Technology (UTFPR)

    International Nuclear Information System (INIS)

    Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Claro, Flavia Del; Perna, Allan F.N.; Reque, Marilson; Levchuk, Leonid; Denyak, Valeriy; Schelin, Hugo R.; Rocha, Zildete; Santos, Talita O.

    2013-01-01

    The present work describes the principal results concerning the radon and radium measurements at Curitiba (PR) urban area during the last decade. The monitoring was performed in cooperation with the Center of Nuclear Technology Development (CDTN/CNEN). For radon in air activity measurements, it was used polycarbonate etched track detectors such as LEXAN and CR-39, mounted in diffusion chambers. For soil gas measurements, the experimental setup was based on the Professional AlphaGUARD Radon Monitor connected to the Soil Gas Probe, filter vessels and air pump (AlphaPUMP), following the recommended protocols elaborated in the Soil-Gas Radon Intercomparison Measurements performed at different Countries of the world. In the case of radon tests in drinking water, the experimental setup was based on the AlphaGUARD Radon monitor and Electronic Radon Detector RAD7 connected to a special kit of glass vessels through the air pump. The obtained results permitted to identify few dwellings where radon concentration in air was found bigger than 600 Bq/m 3 , that is considered as the action level by most of the European Community and the World Health Organization (WHO). In the case of well water, collected samples presented the average Rn-222 activity of about 60 Bq/L, that is 6 times bigger than the maximum level recommended by USEPA. Some artesian wells presented radon activity of almost 200 Bq/L. More over, almost all water samples presented the radioactivity of radium (Ra-226) salts bigger than the upper limit for global alpha radioactivity of potable water established by the Norms and Regulation of the Brazilian Ministry of Health. (author)

  6. Measurement of indoor and outdoor radon concentrations during Superstorm Sandy.

    Science.gov (United States)

    Kotrappa, Payasada; Paul, Prateek; Stieff, Alex; Stieff, Frederick

    2013-12-01

    Superstorm Sandy affected much of the US East Coast extending over 1800 km. It passed over the test location in the State of Maryland on 29 October 2012. Being 350 km away from the regions of highest intensity the storm was of lower intensity at the test location. Continuous radon monitors and passive radon monitors were used for the measurement. The test location was the basement of a single family home representing the indoor concentration. A partially opened garage of the same test home represented the outdoor radon concentration. In 24 h, the atmospheric pressure dropped from 990 to 960 mbar and the indoor radon concentration increased from 70 to 1500 Bq m(-3) and returned to the normal of 70 Bq m(-3) at the end of the storm. Throughout the storm, the outdoor radon concentration was not significantly affected. Probable reasons for such surprisingly large changes are discussed. However, the outdoor temperature dropped from 13°C to 7°C during the radon peak.

  7. Radon in an underground excavation site in Helsinki

    International Nuclear Information System (INIS)

    Venelampi, E.

    2004-01-01

    The paper reports on radon measurements and actions taken in a large underground excavation site in Helsinki, where a coal store was excavated underneath an existing power plant. The measurements were carried out by taking grab samples using Lucas type scintillation cells. Large variations in radon concentrations were observed during the three-year study. The reasons for variations are discussed and recommendations are given for radon monitoring procedures in underground excavation sites. The importance of ventilation to reduce the radon level is stressed. (P.A.)

  8. Determination of radon in the air of housings of the Aguascalientes municipality; Determinacion de radon en el aire en viviendas del municipio de Aguascalientes

    Energy Technology Data Exchange (ETDEWEB)

    Jasso G, M.R.; Lira P, M.G.; Bonilla P, A.; Ruvalcaba S, L.; Gutierrez S, K.M.; Sandoval A, G.E. [Instituto Tecnologico de Aguascalientes, Av. Lopez Mateos 1801, 20256 Aguascalientes (Mexico); Sanchez H, L. [CNSNS, Dr. Barragan 779, 03020 Mexico D.F. (Mexico)]. e-mail: jassogonzalezre@yahoo.com.mx

    2006-07-01

    This study reports the results of the first exploratory sampling of the radon concentration in the air in a group of housings of the Aguascalientes City, Mexico. The municipality of Aguascalientes was divided in 4 sampling areas considering a total of 179 housings. In these housings, the radon concentration in the air was monitored during a period of 10 days. The results obtained in this study indicate that the radon concentration in the air of 45% of the sampling housings overcomes the concentration limit of 250 Bq/m{sup 3} suggested by the EPA. (Author)

  9. Development of a small-sized radon data logger

    International Nuclear Information System (INIS)

    Tasaka, Shigeki; Sasaki, Yoshimi

    1996-01-01

    A small-sized radon data logger and a electrostatic collecting radon monitor were developed for the continuous monitoring of environmental radon and radon daughters. A PIN photodiode (PD), an alpha particle defector, installed inside a container attracts radon daughters when charged electrostatically. Alpha particles are completely separated from each other according to the energy level. New logger has made it possible 10 analysts and save the radon data. Alpha particle count data from radon daughters are automatically integrated over preset time intervals and the energy regions. The desiccant P 2 O 5 was placed in the bottom of the monitor, since the collection efficiency of 218 Po atoms depends on the humidity of the air. We can get the 30 days continuous data logging at 30 min sampling frequency at any place with the car battery. We observed the radon concentration of the air inside the Super-Kamiokande dome from Jan-30 to Feb-8-1996. The average of radon concentration was found to be (46±13) Bq/m 3 . (author)

  10. Radon emanometric technique for 226Ra estimation

    International Nuclear Information System (INIS)

    Mandakini Maharana; Sengupta, D.; Eappen, K.P.

    2010-01-01

    Studies on natural background radiation show that the major contribution of radiation dose received by population is through inhalation pathway vis-a-vis contribution from radon ( 222 Rn) gas. The immediate parent of radon being radium ( 226 Ra), it is imperative that radium content is measured in the various matrices that are present in the environment. Among the various methods available for the measurement of radium, gamma spectrometry and radiochemical method are the two extensively used measurement methods. In comparison with these two methods, the radon emanometric technique, described here, is a simple and convenient method. The paper gives details of sample processing, radon bubbler, Lucas cell and the methodology used in the emanometric method. Comparison of emanometric method with gamma spectrometry has also undertaken and the results for a few soil samples are given. The results show a fairly good agreement among the two methods. (author)

  11. Radon distribution in a gasoline-contaminated aquifer

    International Nuclear Information System (INIS)

    Fan, K.; Kuo, T.; Han, Y.; Chen, C.; Lin, C.; Lee, C.

    2007-01-01

    Naturally occurring radon-222 gas in groundwater was investigated as a partitioning tracer to detect non-aqueous phase liquid (NAPL) in a gasoline-contaminated aquifer. The radon-222 activity of groundwater decreased significantly from an average of 7.38+/-1.68BqL -1 measured in monitoring wells located upgradient in the uncontaminated zone to an average of 2.30+/-0.60BqL -1 measured in monitoring wells inside the NAPL source zone. Meanwhile, the radium-226 concentrations measured in aquifer matrix were virtually homogeneous at several locations both upgradient of and inside the NAPL source zone. Furthermore, the NAPL concentration obtained from the Radon Deficit Factor agrees reasonably with the results derived from direct sampling and chemical analysis of soil samples taken from the residual NAPL source zone. The field results of this study confirmed the general applicability of groundwater radon to detect residual NAPL source zone

  12. Contribution of radon and radon daughters to respiratory cancer

    International Nuclear Information System (INIS)

    Harley, N.; Samet, J.M.; Cross, F.T.; Hess, T.; Muller, J.; Thomas, D.

    1986-01-01

    This article reviews studies on the contribution of radon and radon daughters to respiratory cancer and proposes recommendations for further research, particularly a national radon survey. The steady-state outdoor radon concentration averages 200 pCi/m3, and indoor levels are about 4 times higher. The primary source of radon in homes is the underlying soil; entry depends on multiple variables and reduced ventilation for energy conservation increases indoor radon levels. Occupational exposures are expressed in units of radon daughter potential energy concentration or working level (WL). Cumulative exposure is the product of the working level and the time exposed. The unit for cumulative exposure is the working level month (WLM). The occupational standard for radon exposure is 4 WLM/year, and 2 WLM/year has been suggested as a guideline for remedial action in homes. Epidemiologic studies show that miners with cumulative radon daughter exposures somewhat below 100 WLM have excess lung cancer mortality. Some 3% to 8% of miners studied have developed lung cancer attributable to radon daughters. All of the underground mining studies show an increased risk of lung cancer with radon daughter exposure. All cell types of lung cancer increased with radon exposure. If radon and smoking act in a multiplicative manner, then the risk for smokers could be 10 times that for nonsmokers. The potential risk of lung cancer appears to be between 1 and 2 per 10,000/WLM, which yields a significant number of lung cancers as some 220 million persons in the United States are exposed on average to 10 to 20 WLM/lifetime

  13. Field demonstrations of radon adsorption units

    International Nuclear Information System (INIS)

    Abrams, R.F.

    1989-01-01

    Four radon gas removal units have been installed in homes in the Northeast U.S. These units utilize dynamic adsorption of the radon gas onto activated charcoal to remove the radon from room air. Two beds of charcoal are used so that one bed removes radon while the second bed is regenerated using outdoor air in a unique process. The beds reverse at the end of a predetermined cycle time, providing continuous removal of radon from the room air. The process and units have undergone extensive development work in the laboratory as well as in homes and a summary of this work is discussed. This work showed that the system performs very effectively over a range of operating conditions similar to those found in a home. The field test data that is presented shows that scale up from the laboratory work was without problem and the units are functioning as expected. This unit provides homeowners and mitigation contractors with another option to solve the radon gas problem in homes, particularly in homes that it is difficult to prevent radon from entering

  14. A new coating material for reducing indoor radon level

    International Nuclear Information System (INIS)

    Zhuo, W.; Tokonami, S.; Ichitsubo, H.; Yamada, Y.; Yamada, Y.

    2002-01-01

    In order to mitigate indoor radon level, a new fast-setting, solvent-free, polyurethane-based coating material was developed. The permeability of radon gas in the new material was estimated with a simple radon permeation test system set up in this study. It was found that the permeation velocity depended on the thickness of the coating material, and a thickness of 2.0 mm of the coating material seems sufficient for preventing radon permeation. The permeability of radon in the coating material was estimated to be (2.2± 0.8)x10 -10 m 2 ·s -1 for a thickness of about 1.0 mm. The value is much lower than those reported for membrane materials and caulking compounds. For its performance test, the coating material was used in an existing room with high radon level. By spraying a thickness of 1.5 mm of the material, the indoor radon level reduced by about 80%

  15. Factors affecting passive monitoring of radon

    International Nuclear Information System (INIS)

    Asano, Tomohiro; Kahn, B.

    1989-09-01

    In recent years, increasing cancer has been expressed as a possible health hazards associated with long-term exposures to a large population at a low level of radon in the environment. Because radon is ubiquitous nuclide, nation-wide monitoring is necessary to determine lung cancer risk. For such purpose, passive sampling methods with track etch detector or charcoal adsorption collector may have the advantage in lower cost and convenience. The charcoal adsorption collector is considered in this study. Various factors may significantly affect the charcoal adsorption mechanism on its practical application. Moisture effects are discussed here as having major impact on radon collection by charcoal. Set of equations are presented in this report to describe adsorption of radon including moisture effects. (author) 61 refs

  16. Installation and testing of indoor radon reduction techniques in 40 eastern Pennsylvania houses. Final report, October 1984-June 1987

    International Nuclear Information System (INIS)

    Scott, A.G.; Robertson, A.; Findlay, W.O.

    1988-01-01

    This report discusses the installation and testing of indoor radon-reduction techniques in 40 houses in eastern Pennsylvania. Early in 1985, the Pennsylvania Department of Environmental Resources (PDER) started a large radon survey in communities in the Reading Prong (a granite formation) in eastern Pennsylvania, following the discovery of a house with extremely high radon concentrations, greater than 1.2 MBq/cu m. Candidate houses for the program, with radon concentrations in excess of 750 Bq/cu m, were selected from this survey. A total of 40 houses with representative substructure types were chosen from this group, and mitigation methods were selected and installed from June 1985 to June 1987. Initial soil-ventilation installations achieved large reductions in radon concentrations at low cost, but these reductions were not always sustained in colder weather, and several systems were modified during the project to improve their performance. Major reductions in radon concentration were realized in all the houses worked on, with most houses with active soil ventilation systems achieving less than 150 Bq/cu m (4 pCi/L) on an annual average basis in the living areas

  17. Radon and health

    International Nuclear Information System (INIS)

    Chobanova, Nina

    2016-01-01

    Radon is radioactive noble gas that can be found in soil, water, outdoor and indoor air. Since environmental radon on average accounts for about half of all human exposure to radiation from natural sources, increasing attention has been paid to exposure to radon and its associated health risks. Many countries have introduced regulations to protect their population from radon in dwellings and workplaces. In this article are discussed main characteristics of radon, including sources of exposure, variation in radon exposure, how managing risks from radon exposure, how to measure the concentration of radon. There are results of measurements conducted under the 'National radon programme' in Bulgaria also. Key words: radon, sources of exposure, risk, cancer, measure to decrease the concentration [bg

  18. Personal radon daughter dosimetry

    International Nuclear Information System (INIS)

    Stocker, H.

    1979-12-01

    The conventional means of radon daughter exposure estimatikn for uranium miners in Canada is by grab sampling and time weighting. Personal dosimetry is a possible alternative method with its own advantages and limitations. The author poses basic questions with regard to two methods of radon daughter detection, thermoluminescent chips and track-etch film. An historical review of previous and current research and development programs in Canada and in other countries is presented, as are brief results and conclusions of each dosimeter evaluation

  19. Radon gas measurement in Corum

    International Nuclear Information System (INIS)

    Uzbey, S.; Celebi, N.

    2009-01-01

    The existence of the natural radioactive sources in earth's crust which has long half-life and the degradation products of these in the environmental medium such as earth, rocks, foods, water, air, forms the basis of radiation which people are exposed to. Radon is the unique radioactive gas in the nature and it is made up of radium which is the result of uranium degradation. It is necessary to determine the radon concentration because of the difference in the concentration of uranium existence in different places. TAEK (Turkish Atomic Energy Authority) allows 400 Bq/m 3 of radon concentration at houses, 1000 Bq/m 3 at offices per year. In this attempt, government buildings, houses and offices were determined as the sampling places in Corum city center and towns to represent Corum. While disposing the radon measuring detectors, places which are close to the ground level were preferred. 74 radon detectors were left in those places for 60 days and in the end the detectors were collected while discontinuing the connection of environment and they were assessed. According to the results, the average radon gas concentration in 14 government buildings is 71,71 Bq/m 3 , in 15 offices 32,26 Bq/m 3 and at houses 42,34 Bq/m 3 .

  20. Tracing and quantifying groundwater inflow into lakes using a simple method for radon-222 analysis

    Directory of Open Access Journals (Sweden)

    T. Kluge

    2007-09-01

    Full Text Available Due to its high activities in groundwater, the radionuclide 222Rn is a sensitive natural tracer to detect and quantify groundwater inflow into lakes, provided the comparatively low activities in the lakes can be measured accurately. Here we present a simple method for radon measurements in the low-level range down to 3 Bq m−3, appropriate for groundwater-influenced lakes, together with a concept to derive inflow rates from the radon budget in lakes. The analytical method is based on a commercially available radon detector and combines the advantages of established procedures with regard to efficient sampling and sensitive analysis. Large volume (12 l water samples are taken in the field and analyzed in the laboratory by equilibration with a closed air loop and alpha spectrometry of radon in the gas phase. After successful laboratory tests, the method has been applied to a small dredging lake without surface in- or outflow in order to estimate the groundwater contribution to the hydrological budget. The inflow rate calculated from a 222Rn balance for the lake is around 530 m³ per day, which is comparable to the results of previous studies. In addition to the inflow rate, the vertical and horizontal radon distribution in the lake provides information on the spatial distribution of groundwater inflow to the lake. The simple measurement and sampling technique encourages further use of radon to examine groundwater-lake water interaction.

  1. Volume traps - a new retrospective radon monitor

    International Nuclear Information System (INIS)

    Oberstedt, S.; Vanmarcke, H.

    1994-11-01

    A new method to trace back average radon concentrations in dwellings over several decades in time has been developed. This retrospective radon monitor is based on the measurement of the alpha activity of 210 Po deposited in volume traps, for example spongy materials used for mattresses and cushions. Polyester samples with different densities have been exposed to radon-laden air. The exposures correspond to characteristic radon concentrations between 390 Bq/m 3 and 3.9 Bq/m 3 over a 20 years period. The precision in converting the 210 Po signal to the radon exposure has been improved by more than one order of magnitude compared to other common techniques. It is shown that this very sensitive method may be applied to almost all types of volume traps used in households

  2. Research on radon flux reduction from uranium mill tailings

    International Nuclear Information System (INIS)

    Overmyer, R.F.; Thamer, B.J.; Nielson, K.K.; Rogers, V.C.

    1980-01-01

    Radon flux reduction from tailings may be accomplished by the use of an impermeable cover to contain the radon until it decays (half life is 2.8 days). The use of a thick, relatively impermeable cover can attenuate radon flux because a large fraction of the radon would decay before it diffuses through the cover into the atmosphere. This method of reducing radon flux may require soil cover thicknesses on the order of 10 feet. In some locations, obtaining 10 feet of soil to cover 200 acres of tailings may be difficult or may lead to other significant environmental impacts. The Department of Energy is sponsoring research to identify alternatives to thick soil covers for reducing radon flux from uranium tailings to meet the forthcoming standards. The two most effective and practical materials tested thus far are Calcilox and asphalt emulsion. Currently, asphalt emulsions are being tested at the Grand Junction tailings pile in Grand Junction, Colorado, by Battelle Pacific Northwest Laboratory. Other asphalt formulations, such as foamed asphalt that requires less water than asphalt emulsions, may be practical and will be tested this year. Some sulfur-based materials and sulfur-extended asphalt also appear promising and will be tested for effectiveness in reducing radon flux. It is also important to investigate methods of applying various stabilizers to inactive tailings piles in various physical conditions of moisture content, and physical stability. Finally, since the EPA standards for remedial action at tailings piles are stated in terms of radon flux, it is important that radon flux measurements be standardized so that reliable flux measurements can be obtained and directly compared among various laboratories

  3. New devices for radon measurements

    International Nuclear Information System (INIS)

    Sevostyanov, V.N.

    2004-01-01

    This work includes the description of two new devices for radon surveys developed by the authors and produced in Kazakhstan. The first appliance is 'Ramon-Radon-01' used to measure 222 Rn radon in various mediums such as air, water, soil, and radon exhalation. The major advantage of the appliance lies in the absence of radioactive pollution in it after measurements. The appliances widely used in the CIS such as 'RAA-01', 'Alpharad' (produced by 'MTM Zaschita', Russia) and 'Alphaguard' (Germany) take samples directly to the measuring camera. For instance, the activity concentration of samples after they are taken by 'RAA-01' and 'Alpharad' is measured by means of electrostatic precipitation of RaA ( 218 Po) atoms to the square of semiconductor detector with subsequent registration of RaA alpha decay. The obvious disadvantage is that the subsequent measurement of relatively small 222 Rn activity concentration values after great values of 222 Rn activity concentration have been obtained requires a considerable exposure of the appliance sometimes exceeding 10 hours. Therefore, appliances register a relatively low value of the top measurement range of 20 KBq/m 3 . 'Alphaguard' has similar limitation resulting from precipitation of radon daughter decay products on the walls of ionizing chamber where radon activity concentration is measured. The radioactive lag of 'RAA-01', 'Alpharad' and 'Alphaguard' makes them of little use as well for automatic monitoring in the conditions of abruptly time negative derivatives on change of radon activity concentration. The second advantage is that 'Ramon-Radon-01', as opposed to above described appliances, registers almost zero radioactive lag, thanks to its constructive peculiarities which enable an abrupt increase of top range of measured value up to 5x10 5 Bq/m 3 , only limited by velocity of electron units of the appliance. The third advantage is that measurement discontinuity is determined only by time of full measurement cycle

  4. Predicting radon/radon daughter concentrations in underground mines

    International Nuclear Information System (INIS)

    Leach, V.A.

    1984-01-01

    A detailed description of a computer programme is outlined for the calculation of radon/radon daughter concentrations in air. This computer model is used to predict the radon/radon daughter concentrations in Working Level (WL) at the workplace and at the various junctions at either end of the branches in a typical ventilation network proposed for the Jabiluka mine in the Northern Territory

  5. Activity measurements of radon from construction materials.

    Science.gov (United States)

    Fior, L; Nicolosi Corrêa, J; Paschuk, S A; Denyak, V V; Schelin, H R; Soreanu Pecequilo, B R; Kappke, J

    2012-07-01

    This work presents the results of radon concentration measurements of construction materials used in the Brazilian industry, such as clay (red) bricks and concrete blocks. The measurements focused on the detection of indoor radon activity during different construction stages and the analysis of radionuclides present in the construction materials. For this purpose, sealed chambers with internal dimensions of approximately 60×60×60 cm3 were built within a protected and isolated laboratory environment, and stable air humidity and temperature levels were maintained. These chambers were also used for radon emanation reduction tests. The chambers were built in four major stages: (1) assembly of the walls using clay (red) bricks, concrete blocks, and mortar; (2) installation of plaster; (3) finishing of wall surface using lime; and (4) insulation of wall surface and finishing using paint. Radon measurements were performed using polycarbonate etched track detectors. By comparing the three layers applied to the masonry walls, it was concluded that only the last step (wall painting using acrylic varnish) reduced the radon emanation, by a factor of approximately 2. Samples of the construction materials (clay bricks and concrete blocks) were ground, homogenized, and subjected to gamma-ray spectrometry analysis to evaluate the activity concentrations of 226Ra, 232Th and 40K. The values for the index of the activity concentration (I), radium equivalent activity (Raeq), and external hazard index (Hext) showed that these construction materials could be used without restrictions or concern about the equivalent dose limit (1 mSv/year). Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. S. 575: A bill entitled the Radon Testing for Safe Schools Act, introduced in the US Senate, One Hundred Second Congress, First Session, March 6, 1991

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    This bill was introduced into the US Senate on March 6, 1991 to require radon testing in schools. Radon may be especially hazardous to small children who spend a substantial portion of a day in school buildings. On April 20, 1989, the Administrator of the Environmental Protection Agency issued a national advisory recommending that all schools be tested for radon. There is a need for the federal government to provide financial assistance to states and local educational agencies for implementation of measures to reduce elevated levels of radon

  7. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  8. Effects of radon in indoor air studied

    International Nuclear Information System (INIS)

    Auvinen, A.

    1994-01-01

    Radon is an odorless, tasteless and colourless radioactive noble gas that enters indoor air from the ground. Radon causes lung cancer. A committee set up to evaluate the health risks of chemical substances has been drafting a report on radon, which will compile the major research findings on the lung cancer risk posed by radon. Animal tests have shown that even small doses of radon can cause lung cancer. Smokers seem to contract radon-induced lung cancer more readily than non-smokers. Because research findings have been conflicting, however, it is not known exactly how high the risk of lung cancer caused by indoor radon exposure really is. Several major research projects are under way to obtain increasingly accurate risk assessments. An on-going European joint project brings together several studies - some already finished, some still being worked on. In this way it will be possible to get more accurate risk assessments than from individual studies. In order to prevent lung cancer, it is important to continue the work of determining and reducing radon connects and to combat smoking. (orig.)

  9. Radon and thoron progeny levels in air samples at Udagamandalam region of Nilgiris in India

    International Nuclear Information System (INIS)

    Manikandan, N.M.; Selvasekarapandian, S.; Sivakumar, R.; Raghunath, V.M.; Sundaram, V.M.; Santhanam, S.

    2002-01-01

    Measurement of concentration of radon and thoron daughter products in various indoor environment covering four seasons of a year in Udagamandalam Taluk of Nilgiris biosphere has been carried out using a high volume air sampler to assess the inhalation dose to the population which delivers higher dose than the radon and thoron gas alone. The potential alpha-energy concentrations of the radon and thoron progeny ranged from 0.97 to 12.72 mWL and from 1.63 to 15.83 mWL with a geometric mean of 6.02 and 7.89 mWL, respectively, taking all seasons into account. These measurements have yielded a wealth of data on the variation among the indoor radon and thoron progeny in various places during different seasons. The radon and thoron progeny levels are higher in winter seasons and are less in summer season with autumn and spring data lie in between winter and summer. Using the dose conversion factor for indoor exposures given in UNSCEAR 93 report the internal equivalent dose to the inhalation of radon progeny is evaluated to be 1357 μSv x y -1 and the corresponding annual effective dose equivalent value has been found to be 2.13 mSv x y -1 . It can be observed that the mean value of radon is higher than the Indian average. Also it is found the radon and thoron progeny levels are higher in the case of houses built with rock and granite and in tiled type houses of nearly 100 years old. The levels are less in the case of houses built with brick and cement. The observed results for different types of houses and seasons are discussed in this paper. (author)

  10. Monitoring of radon isotopes and affiliated disintegration products (ADP) in soil air and water

    International Nuclear Information System (INIS)

    Anshakov, O. M.; Bogacheva, E. S.; Bouchawach, Fauzi Hadji; Chudakov, V. A.

    2009-01-01

    The subject of research is a physic and mathematical model of the process of radon determining in soil air and water by the way of its sampling for absorbent, preparation of a sample to measurement taking, ADP radiometry: Pb- 214, Bi-214 in a sample, calculation of radon activity concentration in an initial medium. The target of research is experimental determining of assignment parameters of devices, used for radon sampling and measurement of its ADP activity in relation to the methods being developed with estimation of their expected metrological performance, analysis of radon and ADP content for ecological research in relation to objectives of radon and ADP monitoring in environmental objects. (author)

  11. Interactive house investigation and radon diagnostics computer program

    International Nuclear Information System (INIS)

    Gillette, L.M.

    1990-01-01

    This paper reports on the interactive computer program called Dungeons and Radon which was developed as part of the Environmental Protection Agency's (EPA's) Radon Contractor Proficiency (RCP) Program's Radon Technology for Mitigators (RTM) course which is currently being offered in the Regional Radon Training Centers (RRTCs). The program was designed by Terry Brennan to be used in training radon mitigation contractors. The Macintosh based program consists of a series of animated, sound and voice enhanced house scenes. The participants choose where and what to investigate and where to perform diagnostic tests in order to gather enough information to design a successful mitigation system

  12. Building and environmental factors associated with elevated radon levels in rural Iowa homes

    International Nuclear Information System (INIS)

    Weih, L.M.B.

    1993-01-01

    This work examined the relationships between home construction, soil, and climatic factors with radon concentration in 585 rural Iowa homes, screened in winter of 1989. The specific goals of this work were to evaluate the utility of Soil Conservation data in describing radon occurrence in Iowa, and to assess the joint influence of construction and environmental characteristics on predicting radon concentration in homes. A follow-up study in a subset of homes evaluated the variability of radon screening measurements over time. The first part found that the relationship between radon concentration and home construction factors was dependent on location of the radon test in homes. In basements, wall construction and degree of energy efficiency predominated in predicting radon concentration. On upper floors, age of home predominated in predicting radon concentration, with a general decrease in radon concentration with age of home. The second part found that texture of the soil on which the home is located was the most important predictor of radon concentration for homes tested in basements, but the explanatory power was low. Precipitation in the year preceding screening was negatively correlated with radon concentration in homes, but the relationship was only apparent when basement wall type and soil texture were accounted for. Regional trends were not apparent except in describing the relative distribution of soil texture classes across the state. Radon concentration on upper floors of homes was not well described by either soil factors or precipitation. In 1992 a decrease of 36% and 51% from 1989 radon screening levels was found for homes tested in basements and upper floors, respectively. This data set included pair measurements of the same testing location in homes tested in winter 1989. Temperature differences were positively correlated with radon concentration and precipitation differences were not significantly associated with change in radon concentration

  13. Overview of current radon and radon daughter research at LBL

    International Nuclear Information System (INIS)

    1983-01-01

    This report provides a brief summary of radon and radon daughter research at Lawrence Berkeley Laboratory. The radon and radon daughter research program has two broad goals: (1) the study of sources of radon and its subsequent transport into houses, and (2) research on the behavior of radon daughters in indoor environments. Additional research effort is directed to several auxiliary areas, including development of instrumentation and monitoring techniques, studies of indoor air movement, and measurement and control of indoor particulate concentrations

  14. Radon and radon progeny in 70 houses in the Tennessee Valley area: study design and measurement methods

    International Nuclear Information System (INIS)

    Dudney, C.S.; Hawthorne, A.R.; Monar, K.P.; Quillen, J.L.; Clark, C. Jr.; Doane, R.W.; Wallace, R.G.; Reed, R.P.

    1986-01-01

    Levels of radon and its short-lived airborne progeny are being measured in a year-long study of 70 houses in four states in the Tennessee Valley. Various methods were used to solicit volunteers with differing degrees of success. Criteria for selection of houses in the study included presence of a lower level with cement floor and one or more block walls in contact with the soil, absence of obvious indications of technologically enhanced sources of radium, and proximity to one of four cities, (Knoxville, Chattanooga, Birmingham, or Florence). By design, most houses in the study are in the same neighborhood as at least one other house in the study. Houses range in age from newly constructed to about 40 years old. Most of the houses have more than 2000 square feet of finished floor space. The lower level encompasses a garage in most cases. More complete information pertaining to house characteristics will be gathered in the course of the study. Measurements are being made to obtain information on both location- and season-dependent variation of radon and radon progeny. Simultaneous measurements are made quarterly on both upper and lower levels of each house. Grab samples of air are collected and analyzed for radon using a modified Lucas cell technique. Short-term (10-minute) samples of airborne particulate material are collected and analyzed for radon progeny. One-week integrated measurements of working levels are made once each quarter using modified thermoluminescent dosimeters. Both three- and twelve-month integrated measurements of radon using track-etch monitors are being made. 19 references, 1 figures

  15. Applications of commercial liquid scintillation counters to radon-222 and radium-226 analyses

    International Nuclear Information System (INIS)

    Gesell, T.F.; Prichard, H.M.; Haygood, J.R.

    1978-01-01

    The ubiquitous commerical liquid scintillation counter offers automatic sample processing, automatic data recording and the prospect of multiple users. With these features in mind we have explored a number of applications of liquid scintillation counters to environmental and health physics problems. One application, the analysis of radon in water has been described elsewhere and is only briefly reviewed. A method for measuring radon in air, two methods for measuring radium in water, and a technique for leak testing radium needles have also been investigated. An ordinary glass scintillation vial is readily converted into a miniature scintillation flask by coating the inside surface with a thin layer in ZnS:Ag phosphor. The lower limit detection is high, about 2 pCi/1 for a 1 hour count, but these flasks have proved to be useful in situations where a larger number of samples must be taken in environments with relatively high levels of radon. One technique for the detection of radium in water uses liquid-liquid extraction to concentrate radon into an organic scintillation fluid, the other involves passing the water sample through an ion exchange resin and then sealing the resin and scintillation fluid in a vial. Both techniques offer the prospect of easy and inexpensive analyses with limits of detection at or below 0.5 pCi/1. Radium needles can be leak tested by placing them in vials containing toluene for a few minutes, adding fluor to the toluene and counting. Preliminary data regarding these several methods are given

  16. Radon-prone areas in the Lombard plain

    International Nuclear Information System (INIS)

    Sesana, Lucia; Polla, Giancarla; Facchini, Ugo; De Capitani, Luisa

    2005-01-01

    This paper reports the results of indoor radon measurements carried out in the Lombard plain. The aim of this study, which is based on the geological context, was to identify radon high-risk areas. The underlying geology has been established by means of the available stratigraphies giving a schematic representation of the sites in which either occurrence of gravel or silt and clay predominate with depths ranging from 0 to 50 m. Radon measurements were performed in a sample of 411 one-family houses in seven villages located in the southern area of Bergamo and Brescia. The findings indicate that when the substrate is dominated by clay, radon concentration for dwellings on the ground floor are low, whereas a strong predominance of underlying gravel mixed up in sand gives in winter months high radon flux from underground

  17. Radon-prone areas in the Lombard plain

    Energy Technology Data Exchange (ETDEWEB)

    Sesana, Lucia [Istituto di Fisica Generale Applicata, Universita degli Studi di Milano, Via G. Celoria, 16 - 20133 Milan (Italy)]. E-mail: lucia.sesana@unimi.it; Polla, Giancarla [Istituto di Fisica Generale Applicata, Universita degli Studi di Milano, Via G. Celoria, 16 - 20133 Milan (Italy); Facchini, Ugo [Istituto di Fisica Generale Applicata, Universita degli Studi di Milano, Via G. Celoria, 16 - 20133 Milan (Italy); De Capitani, Luisa [Dipartimento di Scienze della Terra, Universita degli Studi di Milano, Via Botticelli, 23 - 20133 Milan (Italy)

    2005-07-01

    This paper reports the results of indoor radon measurements carried out in the Lombard plain. The aim of this study, which is based on the geological context, was to identify radon high-risk areas. The underlying geology has been established by means of the available stratigraphies giving a schematic representation of the sites in which either occurrence of gravel or silt and clay predominate with depths ranging from 0 to 50 m. Radon measurements were performed in a sample of 411 one-family houses in seven villages located in the southern area of Bergamo and Brescia. The findings indicate that when the substrate is dominated by clay, radon concentration for dwellings on the ground floor are low, whereas a strong predominance of underlying gravel mixed up in sand gives in winter months high radon flux from underground.

  18. Radon in Public Waterworks at the Cities of Osijek-Baranja County

    International Nuclear Information System (INIS)

    Radolic, V.; Simatovic, V.; Miklavcic, I.

    2008-01-01

    At the end of year 2007, there was a sampling campaign of water samples from the public waterworks at the cities and municipalities of Osijek-Baranja County. Number of measuring locations was defined by the number of inhabitants in each city or municipality with criterion of 1 location per 3000 inhabitants. Samples were taken from private wells as well, at those municipalities without public waterworks infrastructure. In total, there were performed 130 measurements (19 from private wells). Radon measurements in water samples were performed by Alpha GUARD measuring system using standard procedure for quick measurements. The obtained values in public water-supplies were in range of 0.6 to 15.9 Bq l -1 with arithmetic mean of 4.6 Bq l -1 and standard deviation of 3.6 Bq l -1 . In private wells, the radon values were in range of 4.0 to 17.4 Bq l -1 with arithmetic mean of 9.5 Bq l -1 and standard deviation of 3.3 Bq l -1 . These values are significantly lower than reference level of 100 Bq l -1 recommended by the European Commission; a concentration above this level warrants consideration of possible remedial action. Statistical t-test pointed out there is significant difference between average radon concentrations in water sampled from public water-supplies and those from private wells. The estimated annual effective dose received by an inhabitant of Osijek-Baranja County from ingestion of 2 l water per day from public water-supplies containing averaged 4.6 Bq l -1 of radon is 11.6 μSv/year and 24.2 μSv/year for the consummation of the same amount of water from private wells. In addition, the annual effective dose due to inhalation of radon and its short lived daughters for the population of Osijek-Baranja County is around 175 times greater (2.0 mSv/year) so as the risk for public health.(author)

  19. Variation of radon exhalation on building materials

    International Nuclear Information System (INIS)

    Liu Fudong; Liu Senlin; Wang Chunhong; Pan Ziqiang; Zhang Yonggui; Ji Dong

    2009-01-01

    The 19 samples from different building material factories were collected for four kinds of building materials. The activity concentration and radon exhalation of building materials were measured. The radon exhalations of building materials are not obviously different if the component is same and the processes of building materials are similar. However, the radon exhalations of same kind of building material are greatly different if the components are different and the processes of building material are varied even if the activity concentrations of building material are similar. (authors)

  20. Fluid-based radon mitigation technology development for industrial applications

    International Nuclear Information System (INIS)

    Liu, K.V.; Gabor, J.D.; Holtz, R.E.; Gross, K.C.

    1996-01-01

    The objective of the radon mitigation technology development effort is to develop an efficient and economical radon gas removal technology based on a fluid absorption process. The technology must be capable of cleaning up a wide range of radon gas stream concentrations to a level that meets EPA gas emission standards for residential and industrial applications. Argonne has recently identified a phenomenon that offers the possibility of radon recovery from the atmosphere with high efficiency at room temperature, and radon release at slightly elevated temperatures (50-60 degrees C.) such a device would offer numerous substantial advantages over conventional cryogenic charcoal systems for the removal of radon. Controlled sources of radon in Argonne's radon research facility are being used to quantitatively assess the performance of a selected class of absorbing fluids over a range of radon concentrations. This paper will discuss the design of laboratory- and engineering-scale radon absorption units and present some preliminary experimental test results

  1. A Risk Management Strategy for Radon: The US Experience (invited paper)

    International Nuclear Information System (INIS)

    Boschi, N.

    1998-01-01

    In the United States (US) the Environmental Protection Agency (EPA or Agency) has played a leading role on radon policy. EPA estimates that indoor radon in the US causes approximately 14,000 lung cancer deaths per year with an uncertainty range of 7,000 to 30,000. In 1988, EPA and the Center for Disease Control issued an advisory urging that most houses in the US be tested for radon. The risk assessments have indicated a problem of substantial magnitude. Nonetheless, risk of radon has been assumed to follow a non-threshold model and risk management strategies have been based on the concept that exposures at levels ≥148 Bq.m -3 (4 pCi.1 -1 ). EPA's approach has been to call for voluntary testing, since the Agency does not have direct regulatory authority, and to follow an action guideline of 148 Bq.m -3 . This paper provides an overview of EPA's risk management strategy to control exposure to indoor radon. The first part reviews EPA's approach to radon testing and radon measurement protocols while introducing the option of encouraging homes to be tested and, if necessary, mitigated at the time of any real estate transaction. The second part introduces EPA's voluntary guidelines for construction techniques on how to minimise radon in new homes and addresses how these guidelines could be adopted by the States, local governments, and private sector homebuilders. The third part presents EPA's programme to educate the public on indoor radon risk. The paper concludes by outlining a Congressional directed approach to radon protection based on a multi-media risk management model for radon in air and water. (author)

  2. Radon dosimetry: a review of radon and radon daughter exposure conditions in dwellings and other structures

    International Nuclear Information System (INIS)

    Ryan, M.T.; Goldsmith, W.A.; Poston, J.W.; Haywood, F.F.; Witherspoon, J.P.

    1983-07-01

    Within the past few years several situations have been brought to light which indicate an increased radiation exposure of certain segments of the general population caused by human activities. The most widely publicized activities are those associated with the mining and milling of uranium in the western United States, the phosphate industry in Florida, and those potential problems represented by former Manhattan Engineer District sites. One of the primary problems involves exposure to radon and radon daughters which are released from large waste piles or, in some cases, evolve from backfill and construction materials used in homes, schools, and other buildings. This report presents a review of the available data on radon and radon daughter concentrations in dwellings and other structures. The primary objectives were to compile and tabulate pertinent radon exposure data and to prepare a statistical summary of the data which will be useful in the prediction of normal levels of radon and radon daughter concentrations in these structures. In addition, other parameters associated with radon exposure conditions are presented and discussed

  3. Mapping the geogenic radon potential of the eastern Canary Islands.

    Science.gov (United States)

    Rubiano, Jesús G.; Alonso, Hector; Arnedo, Miguel. A.; Tejera, Alicia; Martel, Pablo; Gil, Juan M.; Rodriguez, Rafael; González, Jonay

    2014-05-01

    The main contribution of indoor radon comes from soils and thus, the knowledge of the concentration of this gas in soils is important for estimating the risk of finding high radon indoor concentrations. To characterize the behavior of radon in soils, it is common to use the a quantity named Radon Potential which results of a combination of properties of the soil itself and from the underlying rock, such as concentration and distribution of radium, porosity, permeability, the moisture content and meteorological parameters, among others. In this work, the results three year of campaigns of measurement radon gas as well as the permeability in soils of the Eastern Canary Islands (Gran Canaria, Fuerteventura and Lanzarote) are presented. By combining these two parameters and through the use of geostatistic interpolation techniques, the radon potential of soils is estimated and it is used to carry on a classification of the territory into hazard zones according to their potential for radon emanation. To measure the radon soil gas a probe equipped with a "lost" sharp tip is inserted to the desired sampling depth. One of the characteristics of the Canary Islands is the absence of developed soils and so the bedrock is found typically at very shallow depth. This fact has led us to adopt a sampling depth of 50 cm at most. The probe is connected to the continuous radon monitor Durridge RAD7 equipped with a solid-state alpha spectrometer to determine concentration radon using the activity its short-lived progeny. Dried soil air is delivered to the RAD7 radon monitor by pumping. A half hour counting time for all sampling points has been taken. In parallel to the radon measurement campaign, the permeability of soils has also been determined at each point using the permeameter RADON-JOK. The principle of operation of this equipment consists of air withdrawal by means of negative pressure. The gas permeability is then calculated using the known flow of air flowing through the probe

  4. Radon Exhalation from some Finishing Materials Frequently used in Syria

    International Nuclear Information System (INIS)

    Shweikani, R.; Raja, G.

    2011-01-01

    Building materials are one of the main radon sources in dwellings. Therefore, the determination of radon exhalation from these materials will help in prediction the existence of dwelling with potential radon risk. Ceramic tiles and marble samples were collected from Syrian local market. The correlation between radon exhalation from these materials and radium-226 content was studied. Results showed that there is no clear relation between radium content and radon exhalation rate, and the exhalation of radon did not exceed the permissible limits of American Environment Protection Agency (EPA). In addition, the additional annual dose from radon and gamma of the natural radioactivity in ceramic and marble when used as finishing materials in houses was also estimated and found to be not exceeding 20 μSv and 35 μSv from radon and gamma respectively. (author)

  5. Radon exhalation from some Finishing Materials frequently used in Syria

    International Nuclear Information System (INIS)

    Shweikani, R.; Raja, G.

    2009-02-01

    Building materials are one of the main radon sources in dwellings. Therefore, the determination of radon exhalation from these materials will help in prediction the existence of dwelling with potential radon risk. Ceramic tiles and marble samples were collected from Syrian local market. The correlation between radon exhalation from these materials and radium-226 content were studied. Results showed that there is no clear relation between radium content and radon exhalation rate, and the exhalation of radon did not exceed the permissible limits of American Environment Protection Agency (EPA). In addition, the additional annual dose from radon and gamma of the natural radioactivity in ceramic and marble when used as finishing materials in houses were also estimated and found to be not exceeding 20 μSv and μ35 Sv from radon and gamma respectively. (author)

  6. Express method and radon gas measurement detector

    International Nuclear Information System (INIS)

    Khajdarov, R.A.; Khajdarov, R.R.

    2004-01-01

    The purpose of this work was to improve the activated charcoal adsorption method. The detector consisted of an electronic unit (200 mm x 180 mm x 80 mm) and a scintillation cell (a tube 200 mm long, 60 mm diam.). The electronic unit contained a power supply, amplifier, discriminator, timer, counter and indicator. The scintillation cell contained a zinc sulfide scintillator, photomultiplier, preamplifier, high voltage power supply and a 200 ml chamber above the scintillator. This chamber was intended to situate activated carbon fibrous absorber and air compressor. In this method, air is drawn through a filter to remove radon decay products and then through the activated carbon cloth by using a compressor. Sampling takes between 5 and 15 minutes. After the sampling, the cloth is heated for 5-10 sec up to 200-250 deg C by electric current passing through the fiber. Radon gas evaporates from the cloth and the device detects scintillation pulses. Owing to a high radon preconcentration factor (by adsorption of radon on the activated carbon cloth from 50-150 L of air of and evaporation into the small volume of the chamber), the detection limit of the method is 2-4 Bq/m 3 . Since the distance between the filter, cloth and scintillator is over 80 mm, the detector only measures radiation from radon without interference from the radon decay products, remaining in the filter and cloth

  7. Cost effectiveness of radon mitigation in Canada

    International Nuclear Information System (INIS)

    Letourneau, E.G.; Krewski, D.; Zielinski, J.M.; McGregor, R.G.

    1992-01-01

    This paper examines the cost effectiveness of comprehensive strategies for reducing exposure to radon gas in indoor air in Canadian homes. The analysis is conducted within the context of a general framework for risk management programme evaluation which includes well-known evaluation techniques such as cost effectiveness and cost-benefit analyses as special cases. Based on this analysis, it is clear that any comprehensive programme to reduce exposure to environmental radon will be extremely expensive, and may not be justifiable in terms of health impact, particularly when considered in relation to other public health programmes. Testing of homes at the point of sale and installing sub-slab suction equipment to reduce exposure to indoor radon where necessary appears to be a relatively cost-effective radon mitigation strategy. In general, radon mitigation was found to be most cost effective in cities with relatively high levels of radon. (author)

  8. S. 2844: A Bill to provide for radon testing. Introduced in the Senate of the United States, One Hundredth Congress, Second Session, September 29, 1988

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This bill, entitled as the Department of Housing and Urban Development Radon Policy Act, has been introduced to provide for radon testing. The purposes of this Act are to: provide the Department of Housing and Urban Development with a mandate to establish a departmental radon policy and program; require the Department of Housing and Urban Development to use its programs to assist the EPA in addressing radon contamination; and require the Department of Housing and Urban Development, in coordination with the EPA, to develop a radon assessment and mitigation program which utilized EPA recommended guidelines and standards to ensure that occupants of housing covered under this Act are not exposed to elevated levels of radon

  9. Background concentrations of radon and radon daughters in Canadian homes

    International Nuclear Information System (INIS)

    McGregor, R.G.; Vasudev, P.; Letourneau, E.G.; McCullough, R.S.; Prantl, F.A.; Taniguchi, H.

    1980-01-01

    Measurements of radon and radon daughters were carried out in 14 Canadian cities on a total of 9999 homes selected in a statistically random manner. The geometric means of the different cities varied from 0.14 to 0.88 pCi/l. for radon and 0.0009 to 0.0036 Working Levels for radon daughters. The radon originates from natural radioactivity in the soil surrounding the homes. (author)

  10. Measurements of radon exhalation from building materials under model climate conditions

    International Nuclear Information System (INIS)

    Jann, O.; Schneider, U.; Koeppke, J.; Lehmann, R.

    2003-01-01

    The inhalation of 222 Rn (radon) is the most important reason for lung cancer as a result of smoking. The cause for enhanced radon concentration in the air of buildings is mostly the building ground. But also building products can lead to increased radon concentrations in indoor air when the products contain raw materials or residues with higher contents of 226 Ra (radium), especially in combination with low air exchange rates. For a realistic estimation of radon concentrations it is helpful to perform emission tests on the basis of emission test chambers. Emissions test chambers are already used successfully for the measurement of volatile organic compounds (VOC) emitted from different materials and products. The analysis of radon in air was performed with a test device based on the principle of ionisation chamber (ATMOS 12 D). It could be show that radon concentrations emitted from building materials can be determined reliably if certain boundary conditions such as temperature, relative humidity and especially area specific air flow rate are met. It was also shown that reduced area specific air flow rates or reduced air exchange rates lead to higher radon concentrations. It is remarkable that no conclusion can be drawn from the activity concentration of radium to the radon concentration in the air. Therefore in some cases much higher radon concentrations in air were determined that had been expected. Obviously diffusion within the material plays an important role. (orig.)

  11. Monitoring employee exposure to radon and its daughters in uranium mines

    International Nuclear Information System (INIS)

    Leach, V.A.; Lokan, K.H.

    1979-06-01

    Practical methods for measuring the concentration in air of radon and radon daughter are reviewed, and straightforward procedures are described for reliable field measurements. Typical field data, and sample calculations are provided, together with suitable procedures for calculating and reporting cumulative radon daughter exposures

  12. Follow-up durability measurements and mitigation-performance improvement tests in 38 Eastern Pennsylvania houses having indoor radon-reduction systems. Final report, Oct 89-Feb 90

    International Nuclear Information System (INIS)

    Findlay, W.O.; Robertson, A.; Scott, A.G.

    1991-03-01

    The report gives results of follow-up tests in 38 difficult-to-mitigate Pennsylvania houses where indoor radon reduction systems had been installed 2 to 4 years earlier. Objectives were to assess system durability, methods for improving performance, and methods for reducing installation and operating costs. The durability tests indicated that the 38 systems have not experienced any significant degradation in indoor radon levels or in system flows/suctions, except in 6 houses where system fans failed, and in houses where homeowners turned off the systems. Tests to improve performance indicated that nearly all of the elevated residual radon levels are due to re-entrainment back into the house of very-high-radon exhaust gas from the soil depressurization systems, and to radon release from well water. Tests to reduce system costs showed that premitigation sub-slab suction field measurements can help prevent installation of too many suction pipes when communication is good, but suggest a need for too many pipes when communication is poor. Soil depressurization fans could not be turned down to the extent expected in some systems that were over-designed. Between 6 and 42% of the exhausted air was withdrawn from the house

  13. Radon exhalation from building materials for decorative use

    Energy Technology Data Exchange (ETDEWEB)

    Chen Jing, E-mail: jing.chen@hc-sc.gc.c [Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa K1A 1C1 (Canada); Rahman, Naureen M.; Atiya, Ibrahim Abu [Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa K1A 1C1 (Canada)

    2010-04-15

    Long-term exposure to radon increases the risk of developing lung cancer. There is considerable public concern about radon exhalation from building materials and the contribution to indoor radon levels. To address this concern, radon exhalation rates were determined for 53 different samples of drywall, tile and granite available on the Canadian market for interior home decoration. The radon exhalation rates ranged from non-detectable to 312 Bq m{sup -2} d{sup -1}. Slate tiles and granite slabs had relatively higher radon exhalation rates than other decorative materials, such as ceramic or porcelain tiles. The average radon exhalation rates were 30 Bq m{sup -2} d{sup -1} for slate tiles and 42 Bq m{sup -2} d{sup -1} for granite slabs of various types and origins. Analysis showed that even if an entire floor was covered with a material having a radon exhalation rate of 300 Bq m{sup -2} d{sup -1}, it would contribute only 18 Bq m{sup -3} to a tightly sealed house with an air exchange rate of 0.3 per hour. Generally speaking, building materials used in home decoration make no significant contribution to indoor radon for a house with adequate air exchange.

  14. Radon soil gas measurements in a geological versatile region as basis to improve the prediction of areas with a high radon potential

    International Nuclear Information System (INIS)

    Kabrt, Franz; Rechberger, Fabian; Schuff, Michael; Seidel, Claudia; Baumgartner, Andreas; Friedmann, Harry; Maringer, Franz Josef

    2014-01-01

    With the aim to predict the radon potential by geological data, radon soil gas measurements were made in a selected region in Styria, Austria. This region is characterised by mean indoor radon potentials of 130-280 Bq m -3 and a high geological diversity. The distribution of the individual measuring sites was selected on the basis of geological aspects and the distribution of area settlements. In this work, the radon soil gas activity concentration and the soil permeability were measured at 100 sites, each with three single measurements. Furthermore, the local dose rate was determined and soil samples were taken at each site to determine the activity concentration of natural radionuclides. During two investigation periods, long-term soil gas radon measurements were made to study the time dependency of the radon activity concentration. All the results will be compared and investigated for correlation among each other to improve the prediction of areas with high radon potential. (authors)

  15. Indoor Air '93. Particles, microbes, radon

    International Nuclear Information System (INIS)

    Kalliokoski, P.; Jantunen, M.; Seppaenen, O.

    1993-01-01

    The conference was held in Helsinki, Finland, July 4-8, 1993. The proceedings of the conference were published in 6 volumes. The main topics of the volume 5 are: (1) particles, fibers and dust - their concentrations and sources in buildings, (2) Health effects of particles, (3) Need of asbestos replacement and encapsulation, (4) Seasonal and temporal variation of fungal and bacterial concentration, (5) The evaluation of microbial contamination of buildings, (6) New methods and comparison of different methods for microbial sampling and evaluation, (7) Microbes in building materials and HVAC-systems, (8) Prevention of microbial contamination in buildings, (9) Dealing with house dust mites, (10) Radon measurements and surveys in different countries, (11) The identification of homes with high radon levels, (12) The measurement methods and prediction of radon levels in buildings, and (13) Prevention of radon penetration from the soil

  16. Radon in public buildings; Radon in oeffentlichen Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, H.; Flesch, K. [IAF - Radiooekologie GmbH, Dresden (Germany); Hermann, E. [B.P.S. Engineering GmbH, Zwickau (Germany); Loebner, W. [Wismut GmbH, Chemnitz (Germany); Leissring, B. [Bergtechnisches Ingenieurbuero GEOPRAX, Chemnitz (Germany)

    2009-07-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  17. Thoron and radon measurements in houses

    International Nuclear Information System (INIS)

    Gauthier, C.

    1980-01-01

    Studies were made to determine what effect thoron daughters have on radon working level measurements in occupied houses at Elliot Lake. The decay of radon daughters is faster than that of thoron daughters. Six hours after sampling radon daughters are no longer present on the filter, and essentially all alpha activity is due to thoron C in transient equilibrium with thoron B. The concentrations can be extrapolated back to the time of the Kuznetz count, and the WL overestimation due to the presence of thoron daughters calculated. It was found using this method that in 70 percent of the samples the thoron contribution was no more than one mWL equivalent, less than the statistical error in the estimation of working levels. Only in buildings with very low ventilation rates and large areas of exposed concrete may corrections for the presence of thoron be necessary

  18. Radon in workplaces in Extremadura (Spain)

    International Nuclear Information System (INIS)

    Martín Sánchez, A.; Torre Pérez, J. de la; Ruano Sánchez, A.B.; Naranjo Correa, F.L.

    2012-01-01

    Indoor radon measurements are usually associated with housing. However, a typical person spends about one-third of the day at their workplace. A survey was made of radon levels in workplaces in Extremadura (Spain). More than 200 measurements were performed in some 130 firms and organizations of different sectors (urban wellness centres, spas, caves, mines, water management facilities, underground carparks, wine cellars, museums, etc.). Activated charcoal canisters and track detectors were used for sampling. The results indicated the importance of performing this type of measurement because the exposure of workers can reach high values in some cases. - Highlights: ► More than 200 measurements were performed in about 130 working places. ► Activated charcoal canisters and track detectors were used for sampling. ► The exposure of workers can reach high values in some cases. ► Geological characteristics of the soil influence the indoor radon levels.

  19. Measurement Testing of Radon Gas for Fault Activity Detection in Rahtawu Muria, Pati

    International Nuclear Information System (INIS)

    Suntoko, Hadi; Hamzah, Imam

    2004-01-01

    The radon surface can be used to investigates not only for environment but also to be develop in an earth application. The investigation is carried out at the Rahtawu fault, that includes, to the Pati regency which is located 40 km South of ULA. The objective of study to measure the radon released from the fracture zone activities. RDA equipment is being used to measure the radon gas released. The result shown that the high value of radon is 311 cpm with the background of 18 cpm, whereas the low value falls at 0 cpm. The tattoo value are influenced by the soil condition, tattoo time, hardness, weather, soil/stone porosity and fault possession. (author)

  20. An open loop equilibrator for continuous monitoring of radon at the groundwater-surface water interface

    International Nuclear Information System (INIS)

    Kil Yong Lee; Yoon Yeol Yoon; Soo Young Cho; Eunhee Lee; Sang-Ho Moon; Dong-Chan Koh; Kyoochul Ha; Yongcheol Kim; Kyung-Seok Ko

    2015-01-01

    A continuous monitoring system (CMS) using an open loop equilibrator for assessment of 222 Rn at the groundwater-surface water interface was developed and tested. For the characterization and validation of the system, three air loops (open loop, closed loop, and open bubble loop) were tested in relation to high and precise count rates, rapid response, and equilibration of radon. The water and air stream is fed to the equilibrator by an experimental setup with a commercial submersible water pump and the internal pump with built-in radon-in-air detector. Efficiency calibration of the CMS is done by simultaneous determination of a groundwater sample using liquid scintillation counting, and the RAD7 accessories RAD-H 2 O, BigBottle RAD-H 2 O. The higher count rates are provided by the closed loop. However, the open loop with bubbler (open bubble loop) provides the best precision count rates, rapid response, and equilibration time. The CMS allows radon determination in discrete water samples as well as continuous water streams. (author)

  1. Studies of radon mitigation in well water by aeration

    International Nuclear Information System (INIS)

    Mafra, Karina Cristina; Paschuk, Sergei A.; Denyak, Valeriy; Reque, Marilson; Correa, Janine Nicolosi; Barbosa, Laercio

    2011-01-01

    The 222 Rn concentration in natural water in different countries usually is about few Bq/L and is the subject of the National legislation as well as International norms and recommendations. The United States Environmental Protection Agency (USEPA) established a limit of 11.1 Bq/L for the radon level in drinking water and this limit is considered as guideline in Canada and many countries of the European Union. This work presents the results of study of radon ( 222 Rn) concentration reduction in well water using the aeration process developed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR). The water samples were collected from a well at Pinheirinho region of Curitiba in 2011. Experimental setup was based on the Radon Monitor (AlphaGUARD). The 222 Rn concentration was analyzed using the software DataEXPERT by Genitron Instruments, taking into account the volume of water sample, its temperature, atmospheric pressure and the total volume of the air in the vessels. Initial concentration of radon in water samples was 28,67 Bq/L which is bigger than maximum concentration recommended by USEPA. The mitigation was performed by means of diffusion aeration of water samples of 15L during the time interval of 24 hours following a period of 4 days. The efficiency of aeration mitigation was controlled by comparing the activity of radon in aerated water with reference water samples that were not aerated. Obtained results show very satisfactory decrease of 222 Rn activity in water samples even after few hours of intense aeration. (author)

  2. Measurements of indoor radon and radon progeny in Mexico City

    International Nuclear Information System (INIS)

    Cheng, Y.S.; Rodriguez, G.P.

    1996-01-01

    Indoor radon has been a public concern associated with increased lung cancer risks. Radon decay products interact with indoor aerosols to form progeny with different size distributions, which may influence the lung dosimetry when the progeny are inhaled. Air pollution in Mexico City is a serious problems with high particulate concentrations, but there are few reports of indoor radon measurement. The purposes of this study were to measure the aerosol concentration, radon concentration, and radon activity size distribution in the living area of three houses in Mexico City. The radon concentration was monitored by a RGM-3 radon gas monitor (Eberline, Inc., Santa Fe, NM). A graded diffusion battery was used to determine the progeny concentration and activity size distribution. The concentration and size distribution of the indoor aerosols were monitored by a quartz, crystal microbalance cascade impactor. Our measurements showed high concentrations of indoor aerosols (20-180 gg m -3 ). However, the radon concentrations-were low ( -1 ), but showed a clear diurnal pattern with peak concentrations from 2-10 AM. The activity size distributions of radon progeny were trimodal, with peaks of 0.6 nm, 4-5 nm, and 100 rim. Most activities were associated with large particle sizes. Our results indicated that indoor radon concentration was not high, due in part to a relatively high air exchange with outdoor air. The high aerosol concentration may also play an important part in the activity size distribution of radon progeny

  3. Radon monitoring for the prediction of mine outbursts

    International Nuclear Information System (INIS)

    Lebecka, J.; Wysocka, M.; Chalupnik, S.

    1993-01-01

    Observations of changes of concentrations of radon in gases occurring in coal seams prone to instantaneous outbursts of coal and gas have been performed. Gas samples have been taken from specially drilled boreholes. In coal seams prone to outbursts strong variations of radon concentration have been found, while in seams where no outbursts occurred radon concentration was much more stable. In all cases outbursts were always preceded by very low concentrations of radon, which raised again afterwards. Similar observations are performed in coal mines where a strong hazard of shocks accompanied by rock bursts occur which is caused by mining activity. Obtained results indicate the possibility of using radon as supporting indicator for prediction of instantaneous outbursts and rock bursts and may be worth-while for prevention of these catastrophes. (author). 9 refs, 2 figs

  4. Radon and radon daughters in South African underground mines

    International Nuclear Information System (INIS)

    Rolle, R.

    1980-01-01

    Radon and the radon daughters are the radionuclides which primarily determine the level of the radiation hazard in underground uranium mines and to a smaller extent in non-uranium mines. Radon is a gas, and its daughters adsorb on aerosol particles which are of respirable size. The hazard thus arises from the alpha decay of radon and its daughters in contact with lung tissue. Radon is itself part of the uranium decay chain. The major radionuclide, 238 U, decays successively through thirteen shorter-lived radionuclides to 206 Pb. Radon is the only gaseous decay product at room temperature; the other twelve are solids. The main hazard presented by the uranium decay chain is normally determined by the radon concentration because gaseous transport can bring alpha emitters close to sensitive tissue. There is no such transport route for the other alpha emitters, and the level of beta and gamma radiation caused by the uranium decay chain generally presents a far lower external radiation hazard. Radon itself is the heaviest of the noble gases, which are He, Ne, Ar, Kr, Xe and Rn. Its chemical reactions are of no concern in regard to its potential hazard in mines as it may be considered inert. It does, however, have a solubility ten times higher than oxygen in water, and this can play a significant part in assisting the movement of the gas from the rock into airways. Radon continuously emanates into mine workings from uranium ores and from the uranium present at low concentrations in practically any rock. It has been found that the control of the exposure level is most effectively achieved by sound ventilation practices. In South African mines the standard of ventilation is generally high and exposure to radon and radon daughters is at acceptably low levels

  5. Radon Survey in Kalamata (Greece)

    International Nuclear Information System (INIS)

    Geranios, A.; Kakoulidou, M.; Mavroidi, Ph.; Moschou, M.; Fisher, S.; Burian, I.; Holecek, J.

    2001-01-01

    A national radon survey is still lacking for Greece. Some groups have carried out several more or less local or extended radon surveys and valuable experience has been gained. After the first preliminary survey carried out by our group, where 500 Kodak LR-115 etched track detectors were placed in Greek schools and dwellings for one year, indoor radon measurements were continued by placing the same number of detectors in a restricted area, covering the city of Kalamata (a medium size city with 60,000 inhabitants), situated in the south of Peloponnese. Although Kalamata was not of special radon interest, the local authorities insisted on knowing for their citizens' sake the level of this natural radiation. At first, the intention was to use a different method of organisation and distribution of the etched-track detectors from the previous one, attempting mainly to acquire more reliable results and to collect as many detectors as possible. Secondly, it was of great importance to test the statistics of the indoor radon concentrations for a rather small area, and thirdly, to estimate independently the annual absorbed dose by children, taking into account radon concentrations measured both in their home and at school. The set of detectors' readings (about 370), revealed, in general, lower values for Kalamata, compared to the ones found in the preliminary radon survey in Greece and almost all concentrations were found to be below the NRPB action level (200 Bq.m -3 ) (author)

  6. Radon in soil gas in Kosovo.

    Science.gov (United States)

    Kikaj, Dafina; Jeran, Zvonka; Bahtijari, Meleq; Stegnar, Peter

    2016-11-01

    An assessment of the radiological situation due to exposure to radon and gamma emitting radionuclides was conducted in southern Kosovo. This study deals with sources of radon in soil gas. A long-term study of radon concentrations in the soil gas was carried out using the SSNTDs (CR-39) at 21 different locations in the Sharr-Korabi zone. The detectors were exposed for an extended period of time, including at least three seasonal periods in a year and the sampling locations were chosen with respect to lithology. In order to determine the concentration of the natural radioactive elements 238 U and 226 Ra, as a precursor of 222 Rn, soil samples were collected from each measuring point from a depth of 0.8 m, and measured by gamma spectrometry. The levels (Bq kg -1 ) of naturally occurring radionuclides and levels (kBq m -3 ) of radon in soil gas obtained at a depth 0.8 m of soil were: 21-53 for 226 Ra, 22-160 for 238 U and 0.295-32 for 222 Rn. With respect to lithology, the highest value for 238 U and 226 Ra were found in limestone and the highest value for 222 Rn was found in metamorphic rocks. In addition, the results showed seasonal variations of the measured soil gas radon concentrations with maximum concentration in the spring months. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Measurement Techniques for Radon in Mines, Dwellings and the Environment

    International Nuclear Information System (INIS)

    Snihs, J.O.

    1983-06-01

    Definitions and units appropriate for radon and radon daughters are given. The principle methods of detection are ionization chamber, scintillation technique, nuclear track detector, thermoluminescent discs and alpha spectrometry. The activity concentration is determined by grab sampling and subsequent measurement, frequent or continuous grab sampling and measurement and continuous sampling and long time integrated measurement. Sampling and measurement strategies for mines, dwellings and the environment are discussed. (author)

  8. Development of electret technology to measure indoor radon-daughter concentrations: Final report (Phase 1)

    International Nuclear Information System (INIS)

    Kotrappa, P.; Dempsey, J.C.; Stieff, L.R.

    1989-05-01

    A new type of radon progeny monitor called an electret radon progeny integrating sampling unit (E-RPISU) was developed and demonstrated which uses an electret ion chamber to measure the progeny concentration. A conventional 1 LPM particulate air sampling system is used to collect the progeny on a 35 cm 2 filter which is mounted on the side of the electret ion chamber such that the collected progeny are exposed to the inside of the chamber. The alpha radiation emitted by the progeny collected on the filter ionizes the air in the 220 ml chamber. The ions of opposite polarity collect on the surface of the 127 μm thick electret and reduce its surface voltage. A specially built surface voltmeter is used to measure the electret voltage before and after sampling. The electret voltage drop which occurs during the sampling period is shown to be proportional to the time integrated progeny concentration. Two prototype systems were fabricated and tested in homes and in calibrated radon chambers. The resulting data are presented and analyzed. The calibration factor for the E-RPISU ranged from 1.5 to 2.0 V/mWL-day depending on the electret voltage. Two of the E-RPISUs were delivered to UNC Geotech for further testing. 32 refs., 11 figs., 5 tabs

  9. Radon measurements: the sources of uncertainties

    International Nuclear Information System (INIS)

    Zhukovsky, Michael; Onischenko, Alexandra; Bastrikov, Vladislav

    2008-01-01

    Full text: Radon measurements are quite complicated process and the correct estimation of uncertainties is very important. The sources of uncertainties for grab sampling, short term measurements (charcoal canisters), long term measurements (track detectors) and retrospective measurements (surface traps) are analyzed. The main sources of uncertainties for grab sampling measurements are: systematic bias of reference equipment; random Poisson and non-Poisson errors during calibration; random Poisson and non-Poisson errors during measurements. These sources are also common both for short term measurements (charcoal canisters) and long term measurements (track detectors). Usually during the calibration the high radon concentrations are used (1-5 kBq/m 3 ) and the Poisson random error rarely exceed some percents. Nevertheless the dispersion of measured values even during the calibration usually exceeds the Poisson dispersion expected on the basis of counting statistic. The origins of such non-Poisson random errors during calibration are different for different kinds of instrumental measurements. At present not all sources of non-Poisson random errors are trustworthy identified. The initial calibration accuracy of working devices rarely exceeds the value 20%. The real radon concentrations usually are in the range from some tens to some hundreds Becquerel per cubic meter and for low radon levels Poisson random error can reach up to 20%. The random non-Poisson errors and residual systematic biases are depends on the kind of measurement technique and the environmental conditions during radon measurements. For charcoal canisters there are additional sources of the measurement errors due to influence of air humidity and the variations of radon concentration during the canister exposure. The accuracy of long term measurements by track detectors will depend on the quality of chemical etching after exposure and the influence of season radon variations. The main sources of

  10. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    International Nuclear Information System (INIS)

    Baumgartner, A.; Maringer, F.J.; Michai, P.; Kreuziger, M.

    2006-01-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  11. Active and passive measurements of radon/thoron exhalation from coal and flyash samples collected from various thermal power plants of Delhi, India

    International Nuclear Information System (INIS)

    Singh, Lalit Mohan; Kumar, Rajesh; Sahoo, B.K.; Sapra, B.K.; Rajendra Prasad

    2013-01-01

    Measurement of radon ( 222 Rn) exhalation from coal, flyash and soil samples was carried out using active (Scintillation based Smart Radon Monitor) as well as passive technique (SSNTD based Can technique). In addition, thoron ( 220 Rn) exhalation measurements were also made for the above samples using Scintillation based Smart Thoron Monitor. To the best of our knowledge, thoron exhalation measurement is first of its kind in India. In this study, a total of 26 samples collected from Badarpur Thermal Power Station, Badarpur and Rajghat Power Station, Rajghat, Delhi were analysed. Thoron surface exhalation rate measured by Scintillation based Thoron Monitor for Badarpur Thermal Power Station varied from 327.8 Bq/m 2 /h to 874.2 Bq/m 2 /h and for Rajghat Thermal Power Station it varied from 176.0 Bq/m 2 /h to 781.1 Bq/m 2 /h. Similarly, the radon mass exhalation rate measured by active technique varied from 12.13 mBq/Kg/h to 118.08 mBq/Kg/h for the samples collected from Badarpur Thermal Power Station; while it varied from 15.00 Bq/Kg/h to 168.07 mBq/Kg/h for the samples collected from Rajghat Thermal Power station. On the other hand, result of measurements made by the conventional Can technique were significantly lower varying from 0.44 mBq/Kg/h to 2.34 mBq/Kg/h for Rajghat Thermal Power Station and from 0.78 mBq/Kg/h to 2.88 mBq/Kg/h for Badarpur Thermal Power Station. This vast variation in the results obtained by active and passive techniques is due to the fact that the active technique accounts for the effect of back-diffusion and possible leakage from the chamber in the process of least square fitting of exponential model while it is not so in the case of SSNTD based Can technique. In view of this, results of active technique are more reliable as compared to the passive technique. More importantly, there was no thoron interference in the radon measurement by the active technique. Further experiments are being carried out using controlled radon and thoron

  12. Radon and radon-daughter exposure measurements by through-etched track registration in cellulose nitrate

    International Nuclear Information System (INIS)

    Knoefell, T.M.J.; Silva Estrada, J.J. da; Tavares, O.A.P.; Martins, J.B.

    1981-01-01

    The use of cellulose nitrate films LR-115 type II (Kodak-Pathe) as a practical, exposure integrating device to measure the level of exposure to alpha particles in atmospheres which contain radon and radon-daughter products is investigated. The analysis of a number of cellulose nitrate films that have been exposed to calibrated radon test-chamber atmospheres has indicated good correlations between through-etched track density p and integrated alpha-particle exposure Σa (Working-Level-Hour). It is shown that the response of the cellulose nitrate detector to radon-daughter alpha-particle exposures is linear, and that reliable conservative estimations of the Working-Level-Hour can be obtained from Σa = 3.0(p-b), where p is expressed in tracks/mm 2 (b is the background level). These results recommend the use of the special red cellulose nitrate films as a convenient dosimeter for monitoring radioactive contaminants in mine atmospheres. (Author) [pt

  13. Radon and thoron emanation from various marble materials: impact on the workers

    International Nuclear Information System (INIS)

    Misdaq, M.A.; Amghar, A.

    2005-01-01

    Uranium ( 238 U) and thorium ( 232 Th) concentrations were measured inside different pulverized marble material samples by using a method based on determining detection efficiencies of the CR-39 and LR-115 II solid state nuclear track detectors for the emitted alpha particles. Radon ( 222 Rn) and thoron ( 220 Rn) alpha-activities per unit volume were evaluated inside and outside the marble samples studied. Radon emanation coefficient was determined for the considered marble samples. Alpha- and beta-activities per unit volume of air due to radon, thoron and their progenies were measured in the atmosphere of a marble factory. Equilibrium factors between radon and its progeny and thoron and its decay products were evaluated in the air of the studied marble factory. The committed equivalent doses due to short-lived radon decay products were determined in different regions of the respiratory tract of workers in the considered marble factory

  14. Mapping of groundwater radon potential

    International Nuclear Information System (INIS)

    Aekerblom, G.; Lindgren, J.

    1997-01-01

    The domestic use of water with elevated radon concentration may represent a public health hazard, partly due to the release of radon to the indoor air. While only a limited number of countries have implemented regulations with respect to radon in water, many more are considering doing so. The compulsory limits proposed by Swedish authorities are 100 Bq/1 for public water, while water from private wells is not to exceed 1000 Bq/1. Furthermore, it is recommended that water with a radon content above 500 Bq/1 should not be given to children under five years of age. In Sweden, the estimated number of wells with radon levels above 1000 Bq/1 exceeds 10,000, with a considerable amount in excess of 10,000 Bq/1. The highest radon concentration in a well supplying drinking water encountered so far is 57,000 Bq/1. Radon levels exceeding 500 Bq/1 are almost exclusively found in wells drilled into bedrock and in springs with intramontaneous water. Elevated ground water radon levels require that the water has passed through bedrock with elevated concentration of uranium, or through fractures with coatings of minerals containing enhanced concentrations of radium-226. Intramontaneous water from areas with uranium-bearing rock types (e.g. uranium-rich granites, pegmatites and vulcanites) often manifests elevated radon levels. Routines for the establishment of risk maps focusing on water are currently under development. The backbone of the process is the access to high spatial resolution radiometric information together with bedrock and soil information on a detailed scale (1:50,000). This information is available from the Geological Survey of Sweden, which is routinely carrying out airborne measurements at an altitude of 30 m and a line spacing of 200 m. While some 60% of Sweden is covered up to now, 75 % is expected to be covered within the next ten years. Other available databases utilized in the risk mapping process include radon measurements in wells, geochemical data from

  15. Radon generation and transport. A journey though matter

    Energy Technology Data Exchange (ETDEWEB)

    Cozmuta, I. [Beckman Institute 139-74 Caltech, Pasadena, CA 91125 (United States)

    2001-12-07

    The transport of radon in concrete takes place through the complicated network of interconnected pores that is, at any time, the result of the process of hydration of cement and of moisture distribution and transport. Initially the microstructure of concrete depends on the mix proportions and curing conditions, its time-evolution being conditioned by its surrounding environment. Radon transport will be consequently a function of time, as it is influenced by the changing microstructure (total porosity and its distribution) and by the amount and distribution of the moisture contained in the pore system. A selection of information from the large amount of literature available on concrete is presented in chapter 2. A model that describes the process of hydration, of microstructure development and of moisture transport is presented in chapter 3. The physics of radon diffusion in homogeneous porous materials is outlined in chapter 4. The coupling of the numerical implementation of the hydration and radon transport (chapter 6) offers the possibility to achieve calculated values for porosity and moisture content thus, reducing the number of material parameters in the radon-transport equation that have to be determined experimentally. Chapter 7 covers the experimental methods and techniques. Chapter 5 presents a survey of the information available in literature on radon release from concrete and on radon barriers. This chapter also summarises results of several experimental studies investigating the radon reduction efficiency and also the permeability of various covers. On basis of this information, a selection was made for the covering materials to be assessed in this thesis. Radon-release rates of uncovered and completely covered concrete samples were measured. From these measurements the reduction efficiencies of various sealants (epoxy glue, double-sided aluminised polyethylene foil, soluble glass) were calculated (chapter 12). Also, as a result of the collaboration

  16. Radon generation and transport. A journey though matter

    International Nuclear Information System (INIS)

    Cozmuta, I.

    2001-01-01

    The transport of radon in concrete takes place through the complicated network of interconnected pores that is, at any time, the result of the process of hydration of cement and of moisture distribution and transport. Initially the microstructure of concrete depends on the mix proportions and curing conditions, its time-evolution being conditioned by its surrounding environment. Radon transport will be consequently a function of time, as it is influenced by the changing microstructure (total porosity and its distribution) and by the amount and distribution of the moisture contained in the pore system. A selection of information from the large amount of literature available on concrete is presented in chapter 2. A model that describes the process of hydration, of microstructure development and of moisture transport is presented in chapter 3. The physics of radon diffusion in homogeneous porous materials is outlined in chapter 4. The coupling of the numerical implementation of the hydration and radon transport (chapter 6) offers the possibility to achieve calculated values for porosity and moisture content thus, reducing the number of material parameters in the radon-transport equation that have to be determined experimentally. Chapter 7 covers the experimental methods and techniques. Chapter 5 presents a survey of the information available in literature on radon release from concrete and on radon barriers. This chapter also summarises results of several experimental studies investigating the radon reduction efficiency and also the permeability of various covers. On basis of this information, a selection was made for the covering materials to be assessed in this thesis. Radon-release rates of uncovered and completely covered concrete samples were measured. From these measurements the reduction efficiencies of various sealants (epoxy glue, double-sided aluminised polyethylene foil, soluble glass) were calculated (chapter 12). Also, as a result of the collaboration

  17. Contribution to the improvement of radon risk evaluation in Spain

    International Nuclear Information System (INIS)

    Ortega, X.; Vargas, A.

    2002-01-01

    The 96/29/Euratom Directive aims to introduce radon regulation at working places in European Countries. Within the framework, the Spanish Nuclear Regulatory Body, the Nuclear Safety Council (CSN), is interested in obtaining a reliable level of quality for radon measurements in Spain. The radon laboratory group at the Institute of Energetic Techniques of the Technical University of Catalonia in Barcelona (INTE) has been commissioned to adequate its radon chamber for testing radon instruments using standards as IEC 61577 and ISO 13466

  18. Radon exhalation rates of some granites used in Serbia

    Directory of Open Access Journals (Sweden)

    Nikolić Mladen D.

    2015-01-01

    Full Text Available In order to address concern about radon exhalation in building material, radon exhalation rate was determined for different granites available on Serbian market. Radon exhalation rate, along with mass exhalation rate and effective radium content were determined by closed chamber method and active continuous radon measurement technique. For this research, special chambers were made and tested for back diffusion and leakage, and the radon concentrations measured were included in the calculation of radon exhalation. The radon exhalation rate ranged from 0.161 Bq/m2h to 0.576 Bq/m2h, the mass exhalation rate from 0.167 Bq/kgh to 0.678 Bq/kgh, while the effective radium content was found to be from 12.37 Bq/kg to 50.23 Bq/kg. The results indicate that the granites used in Serbia have a low level of radon exhalation.

  19. High-resolution radon monitoring and hydrodynamics at Mount Vesuvius

    Science.gov (United States)

    Cigolini, Corrado; Salierno, Francesco; Gervino, Gianpiero; Bergese, Paolo; Marino, Ciro; Russo, Massimo; Prati, Paolo; Ariola, Vincenzo; Bonetti, Roberto; Begnini, Stefania

    A yearlong high-resolution radon survey has been carried on at Mount Vesuvius, starting in May 1998. Radon activities were acquired by exposing charcoal canisters and track-etch detectors. Sampling stations were deployed along two major summit faults and around the caldera bottom. Volcanically-related earthquakes, with MD ≥ 2.5, may be discriminated from regional seismic events since their cumulative radon anomalies are recorded from stations located along all the above structural features. On the contrary, radon anomalies correlated to regional earthquakes, with MD ≥ 4, are essentially recorded by the sampling sites located along the two summit faults (whose roots extend deeper into the Tertiary basement rocks that underlay the volcano). Radon migration to the surface is ruled by convection within a porous medium of relatively low porosity (ϕ ≈ 10-5), suggesting that fluid motion is strongly localised along fractures. It is suggested that fluid pressure build up, followed by fluid release and migration during incipient fracturing of the porous medium, precede the onset of volcanically-induced earthquakes.

  20. Radon programme in Czech Republic. Results, experience and future

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.; Fojtikova, I.; Vlcek, J.; Moucka, L.; Fronka, A.; Jilek, K.; Heribanova, A.; Slovak, J.; Barnet, I.; Burian, I.; Jiranek, M.; Cechak, T.

    2004-01-01

    The beginning of the radon programme in the Czech republic dates back to the early 1980s. Incorporated in national legislation (Atomic Act, Radiation Protection Decree), the programme includes now both preventive measures and interventions. Preventive measures are based on the control of major potential radon sources (soil gas, building material and supplied water) to prevent construction of new houses where the recommended indoor radon level of 200 Bq/m 3 would be exceeded. Radon risk (index) assessment of the individual building site bedrock in the case of new house siting and building protection as stipulated by the technical building code are obligatory. The estimation of the radon-related index of building sites is based on a standard method involving a set of radon soil and soil permeability measurements. In addition, producers of building materials are obligated to monitor natural radioactivity in their products. The activity index (including 40 K, 226 Ra and 232 Th) is used as a screening level for regulation of the potential indoor gamma dose rate, and the 226R a mass activity is used as a limiting value for radon exhalation. A similar regulatory system is in place for public water supplies based on obligatory radon, total alpha and total beta measurements. A survey of effectiveness of the preventive measures was carried out during the past years. It appeared, however, that the indoor radon level of 200 Bq/m 3 is exceeded in some 20 % of new houses. An unexpectedly low air exchange rate in modern energy-saving houses seems to be among the reasons. Remedial actions are aimed at promoting targeted indoor radon survey in existing buildings and helping owners to put reasonable remedial measures into effect. Governmental activities include representative and targeted indoor radon survey, subsidies for remediation measures and test measurements, and improving the level of public awareness of the radon issue. Indoor radon survey is targeted on radon-prone areas

  1. Training and accreditation for radon professionals in Sweden

    International Nuclear Information System (INIS)

    Mjoenes, L.; Soederman, A.-L.

    2004-01-01

    Radon training courses and seminars on radon have been arranged in Sweden since the early 1980s. A commercial educational company initiated the first regular training courses in 1987. Up to 1990 about 400 persons had attended courses in radon measurement and radon mitigation methods. In 1991 the training programme was taken over by the Swedish Radiation Protection Authority, SSI. Today SSI's Radon Training Programme comprises three different two-day courses, a Basic Radon Course and two continuation courses: Radon Measurements and Radon in Water. Until 2003 SSI also arranged courses about Radon Remedial Measures and Radon Investigation and Risk Map Production. The courses are arranged twice a year. Altogether, about 750 municipal environmental health officers and technicians from private companies have been educated in the SSI training programme between 1991 and 2003. The continuation courses are completed with an examination, consisting of a theoretical test. The names of the persons who pass are being published in a list that is found on the SSI web site. Since no certification system is currently in place for radon professionals in Sweden, this list helps people who need to get in contact with radon counsellors to find one in their area and is used by authorities as well as private house-owners. Since 1991 it has been possible to obtain accreditation for measurements of indoor radon in Sweden and since 1997, also for measurements of radon in water. Although accreditation is voluntary in Sweden, accredited laboratories perform most measurements, both for indoor air and water. Passing the examination in the SSI training courses is a condition for accreditation. The Swedish Board for Accreditation and Conformity Assessment, SWEDAC, is in charge of the accreditation. So far, three major companies have obtained accreditation for measurement of indoor radon and four have been accredited for measurements of radon in water

  2. Creating Geologically Based Radon Potential Maps for Kentucky

    Science.gov (United States)

    Overfield, B.; Hahn, E.; Wiggins, A.; Andrews, W. M., Jr.

    2017-12-01

    Radon potential in the United States, Kentucky in particular, has historically been communicated using a single hazard level for each county; however, physical phenomena are not controlled by administrative boundaries, so single-value county maps do not reflect the significant variations in radon potential in each county. A more accurate approach uses bedrock geology as a predictive tool. A team of nurses, health educators, statisticians, and geologists partnered to create 120 county maps showing spatial variations in radon potential by intersecting residential radon test kit results (N = 60,000) with a statewide 1:24,000-scale bedrock geology coverage to determine statistically valid radon-potential estimates for each geologic unit. Maps using geology as a predictive tool for radon potential are inherently more detailed than single-value county maps. This mapping project revealed that areas in central and south-central Kentucky with the highest radon potential are underlain by shales and karstic limestones.

  3. Measurement of radon daughters in air samples by alpha spectroscopy

    International Nuclear Information System (INIS)

    Acena, M.L.; Crespo, M.T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of polonium 214 and polonium 218. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter (Author)

  4. The radon transform. Theory and implementation

    International Nuclear Information System (INIS)

    Toft, P.

    1996-01-01

    The subject of this Ph.D. thesis is the mathematical Radon transform, which is well suited for curve detection in digital images, and for reconstruction of tomography images. The thesis is divided into two main parts. Part I describes the Radon- and the Hough-transform and especially their discrete approximations with respect to curve parameter detection in digital images. The sampling relationships of the Radon transform is reviewed from a digital signal processing point of view. The discrete Radon transform is investigated for detection of curves, and aspects regarding the performance of the Radon transform assuming various types of noise is covered. Furthermore, a new fast scheme for estimating curve parameters is presented. Part II of the thesis describes the inverse Radon transform in 2D and 3D with focus on reconstruction of tomography images. Some of the direct reconstruction schemes are analyzed, including their discrete implementation. Furthermore, several iterative reconstruction schemes based on linear algebra are reviewed and applied for reconstruction of Positron Emission Tomography (PET) images. A new and very fast implementation of 2D iterative reconstruction methods is devised. In a more practical oriented chapter, the noise in PET images is modelled from a very large number of measurements. Several packagers for Radon- and Hough-transform based curve detection and direct/iterative 2D and 3D reconstruction have been developed and provided for free. (au) 140 refs

  5. Measurement of radon concentration in water with Lucas cell detector

    International Nuclear Information System (INIS)

    Machaj, B.; Pienkos, J.P.

    2003-01-01

    A method for the measurement of radon concentration in water is presented based on flushing a water sample with air in a closed loop with the Lucas cell as alpha radiation detector. The main feature of the method is washing radon away from the larger sample of water (0.75 l) to a small volume of air, approximately 0.5 l, thanks to which a high radon concentration in air and a considerable sensitivity of measurement is achieved. Basic relations and results of measurements of a model of a gauge is given. The estimated measuring sensitivity (S) is 8.5 (cpm)/(Bq/l). The random error due to the statistical fluctuations of count rate at radon concentrations 1,10, 100, 1000, 10000 Bq/l is 11, 3.6, 1.1, 0.4, 0.1% correspondingly at a counting (measuring) time of 10 min. The minimum detectable radon concentration in water is 0.11 Bq/l. (author)

  6. Radon-safe new buildings, documentation and technology development. Main report; Radonsikring i nybyggeri, dokumentation og teknologiudvikling. Hovedrapport

    Energy Technology Data Exchange (ETDEWEB)

    Breddam Overgaard, L.; Bruun Petersen, J.; Neerup Jeppesen, M.

    2011-07-01

    penetrations with silicone sealant is also the most effective method. In the study it is furthermore concluded that there is no immediate difference in the two radon cavity barrier solutions (above and below the slab). Subproject 3 (radon potential in soil). At an introductory level it has been attempted to survey the radon potential (the amount of radon released from the soil) at the location of the construction of the subproject 1 residential development. The main part of the study consisted of developing and testing a method of ''passive sampling'' by immersion of measuring equipment in 1 m deep drillings. In the study significant radon levels were demonstrated in soil containing tertiary clay (black, micaceous). In comparing the aforementioned passive approach with previous ''active measurements'', it is estimated that passive measurements obtain an approximate expression (average) of the radon level of the entire borehole profile, while soil gas extraction sampling merely expresses a concentration at a level specific point (x m below the surface). The evaluation of the study concluded that satisfactory results had been achieved. It would however be relevant to improve the setup for future follow-up studies (as with subproject 2), and conduct repeated measurements prior to final conclusions. (LN)

  7. Radon diagnostics and tracer gas measurements

    International Nuclear Information System (INIS)

    Jilek, K.; Brabec, M.

    2004-01-01

    An outline is presented of the tracer gas technique, which is used for continuous measurements of air ventilation rate (generally time-varying) and for simultaneous estimation of air ventilation rate and radon entry rate, and some of its limitations are discussed. The performance of this technique in the calculation of the air ventilation rate is demonstrated on real data from routine measurements. The potential for air ventilation rate estimation based on radon measurements only is discussed. A practical application is described of the tracer gas technique to a simultaneous estimation of the air ventilation rate and radon entry rate in a real house where the effectiveness of radon remedy was tested. The following main advantages of the CO tracer gas techniques are stressed: (i) The averaging method continuous determination of the ventilation rate with good accuracy (≤ 20 %). (ii) The newly presented and verified method based on simultaneous measurements of radon concentration and CO gas concentration enables separate continuous measurements of the radon entry rate and ventilation rate. The results of comparative measurements performed with the aim to estimate the inaccuracy in determination of radon entry rate showed acceptable and good agreement up to approximately 10 %. The results of comparative measurements performed with the aim to estimate the mutual commensuration of the method to the determination of the ventilation rate confirmed the expected unreliability the two parametric non-linear regression method, which is the most frequently used method in radon diagnostic in the Czech Republic

  8. Indoor radon

    International Nuclear Information System (INIS)

    1997-12-01

    The radon, a natural radioactive gas, is present almost everywhere on the earth's surface. It can be accumulated at high concentration in confined spaces (buildings, mines, etc). In the last decades many studies conducted in several countries showed that inhaling important amounts of radon rises the risk of lung cancer. Although, the radon is a naturally appearing radioactive source, it may be the subject of a human 'enhancement' of concentration. The increasing radon concentration in professional housing constitutes an example of enhanced natural radioactivity which can induce health risks on workers and public. Besides, the radon is present in the dwelling houses (the domestic radon). On 13 May 1996, the European Union Council issued the new EURATOM Instruction that establishes the basic standards of health protection of population and workers against the ionizing radiation hazards (Instruction 96/29/EURATOM, JOCE L-159 of 29 June 1996). This instruction does not apply to domestic radon but it is taken into consideration by another EURATOM document: the recommendation of the Commission 90/143/EURATOM of 21 February 1990 (JOCE L-80 of 27 March 1990). The present paper aims at establishing in accordance to European Union provisions the guidelines for radon risk management in working places, as well as in dwelling houses, where the implied risk is taken into account. This document does not deal with cases of high radon concentration on sites where fabrication, handling or storage of radium sources take place. These situations must be treated by special studies

  9. New method of reducing radon levels in homes

    International Nuclear Information System (INIS)

    Khaydarov, R.A.; Gapurova, O.U.; Khaydarov, R.R.

    2006-01-01

    Full text: Radon is a naturally occurring gas seeping into homes and underground structures (buildings, tunnels, hangars, garages, etc.) from the surrounding soil through walls, floor, etc. and emanating from construction materials such as concrete, granite, etc. The level of radon is especially great in regions with the heightened content of uranium in soil and water and with geological breaks of the earth's crust. Concentrations of uranium higher than 10 g per ton of soil have been found in 14 percent of territory of Uzbekistan. As a result, for instance, concentration of radon 10-100 times exceeds the regulation level in 14 percent of premises in Tashkent, 41 percent of premises in Almalik town and 44 percent in Yangiabad town. The purpose of this work was creating a method to reduce concentration of radon gas in buildings and underground structures. We suppose that the most effective technique is a treatment of walls, floors, etc. of basement and underground structures by special chemicals which seal micropores inside the construction materials. Sealing the pores stops radon diffusion and in addition, it blocks another radon pathway - water migration and emanation from concrete, gypsum or other construction materials. In the paper polymeric silico organic compounds are investigated and selected as the chemicals to prevent radon seeping indoors. Gas (air, Ar, Rn 222, H 2 O) permeability of concrete and gypsum after treatment by chemicals has been examined. Influence of types of cement and sand, preliminary treatment by different chemicals, different types of polymeric silico organic compounds, time between treatments, moisture of concrete, time between preparation of chemicals and treatment of concrete (aging of chemicals), time between treatment of concrete and testing (aging of treated concrete) have been examined. Surfaces of the samples were treated by spray. Experiments have shown that chosen method of treatment of the construction materials allows reducing

  10. Radon reduction and radon-resistant construction demonstrations in New York state. Final report

    International Nuclear Information System (INIS)

    1991-02-01

    A survey of radon levels in New York State homes indicates that approximately 4.4 percent of the homes have long-term living area radon concentrations above the U.S. EPA guideline of four pCi/l. The project addressed the effectiveness of techniques to reduce the radon level in existing homes and to prevent the occurrence of high radon concentrations in new homes. The goal of the project was to demonstrate the effectiveness of radon reduction techniques in homes containing indoor radon concentrations of more than the current EPA guidelines of four pCi/l. At the same time, radon-resistant construction techniques were demonstrated in homes under construction to provide guidelines for houses being built in areas with a danger of high radon levels. The project demonstrated new radon mitigation techniques in homes containing indoor radon concentrations exceeding four pCi/l; assessed the value of previously installed radon reduction procedures, and demonstrated new radon-resistant construction methods

  11. Measurement of radon concentration in air employing Lucas chamber

    International Nuclear Information System (INIS)

    Machaj, B.

    1997-01-01

    The results of investigations aimed to determine the main features of radon concentration gauge in air, employing 0.17 L Lucas chamber, and air sample forced by an air pump are presented. For two hour sampling and measuring cycle time the dynamic error in the worst case (first read out) equals 5 % relative to the step jump of radon concentration. This is due to the increase of activity of the decay products in the chamber. It was observed that the short lived radon decay products (Po-218, Pb-214, Bi-214) are depositing on the walls of the chamber and they are not removed by flushing the chamber with air. (author)

  12. Mechanisms of radon injury

    International Nuclear Information System (INIS)

    Cross, F.T.

    1988-01-01

    In this new project, they conduct molecular, cellular and whole-animal research relevant to understanding the inhalation toxicology of radon and radon-daughter exposures. The work specifically addresses the exposure-rate effect in radon-daughter carcinogenesis; the induction-promotion relationships associated with exposure to radon and cigarette-smoke mixtures; the role of oncogenes in radon-induced cancers; the effects of radon on DNA as well as on DNA repair processes; and the involvement of growth factors and their receptors in radon-induced carcinogenesis. Preliminary experiments showed that oncogenes are activated in radon-induced lung tumors. They have therefore begun further exposures pertinent to the oncogene and growth-factor studies. An in vitro radon cellular-exposure system was designed, and cell exposures were initiated. Initiation-promotion-initiation studies with radon and cigarette-smoke mixtures have also begun; and they are compiling a radon health-effects bibliography

  13. Large-scale radon hazard evaluation in the Oslofjord region of Norway utilizing indoor radon concentrations, airborne gamma ray spectrometry and geological mapping

    International Nuclear Information System (INIS)

    Smethurst, Mark Andrew; Strand, Terje; Sundal, Aud Venke; Rudjord, Anne Liv

    2008-01-01

    We test whether airborne gamma ray spectrometer measurements can be used to estimate levels of radon hazard in the Oslofjord region of Norway. We compile 43,000 line kilometres of gamma ray spectrometer data from 8 airborne surveys covering 10,000 km 2 and compare them with 6326 indoor radon measurements. We find a clear spatial correlation between areas with elevated concentrations of uranium daughters in the near surface of the ground and regions with high incidence of elevated radon concentrations in dwellings. This correlation permits cautious use of the airborne data in radon hazard evaluation where direct measurements of indoor radon concentrations are few or absent. In radon hazard evaluation there is a natural synergy between the mapping of radon in indoor air, bedrock and drift geology mapping and airborne gamma ray surveying. We produce radon hazard forecast maps for the Oslofjord region based on a spatial union of hazard indicators from all four of these data sources. Indication of elevated radon hazard in any one of the data sets leads to the classification of a region as having an elevated radon hazard potential. This approach is inclusive in nature and we find that the majority of actual radon hazards lie in the assumed elevated risk regions

  14. On the behaviour of radon in indoor air

    International Nuclear Information System (INIS)

    Lehtimaeki, M.; Kivistoe, T.

    1983-01-01

    In this work the behaviour of radon in indoor air has been studied. A simple mathematical model is presented to describe the variations in radon concentration in case of a periodic ventilation. This model has been tested with the aid of long-term measurements in two office buildings, in a large shipyard hall, and in a dwelling. The variations predicted by the simple model were observed in all buildings studied. It seems even possible that if the mixing of radon in the building is effective, the radon measurements can be used in estimating the infiltration rates. The measurement in one of the office buildings, however, indicated that the mixing of radon in a many-storied building can be extremely incomplete. The measurements also indicate that the soil can be a very important source of radon. (orig.) [de

  15. Activity measurements of radon from construction materials

    Energy Technology Data Exchange (ETDEWEB)

    Fior, L.; Nicolosi Correa, J. [Federal University of Technology - Parana, UTFPR, Av. Sete de Setembro, 3165, Curitiba, PR 80230-901 (Brazil); Paschuk, S.A., E-mail: spaschuk@gmail.com [Federal University of Technology - Parana, UTFPR, Av. Sete de Setembro, 3165, Curitiba, PR 80230-901 (Brazil); Denyak, V.V. [Federal University of Technology - Parana, UTFPR, Av. Sete de Setembro, 3165, Curitiba, PR 80230-901 (Brazil); Schelin, H.R. [Federal University of Technology - Parana, UTFPR, Av. Sete de Setembro, 3165, Curitiba, PR 80230-901 (Brazil); Pele Pequeno Principe Research Institute, Av. Silva Jardim, 1632, Curitiba, PR 80250-200 (Brazil); Soreanu Pecequilo, B.R. [Institute of Nuclear and Energetic Researches, IPEN, Av. Prof. Lineu Prestes, 2242-/05508-000 Sao Paulo (Brazil); Kappke, J. [Federal University of Technology - Parana, UTFPR, Av. Sete de Setembro, 3165, Curitiba, PR 80230-901 (Brazil)

    2012-07-15

    This work presents the results of radon concentration measurements of construction materials used in the Brazilian industry, such as clay (red) bricks and concrete blocks. The measurements focused on the detection of indoor radon activity during different construction stages and the analysis of radionuclides present in the construction materials. For this purpose, sealed chambers with internal dimensions of approximately 60 Multiplication-Sign 60 Multiplication-Sign 60 cm{sup 3} were built within a protected and isolated laboratory environment, and stable air humidity and temperature levels were maintained. These chambers were also used for radon emanation reduction tests. The chambers were built in four major stages: (1) assembly of the walls using clay (red) bricks, concrete blocks, and mortar; (2) installation of plaster; (3) finishing of wall surface using lime; and (4) insulation of wall surface and finishing using paint. Radon measurements were performed using polycarbonate etched track detectors. By comparing the three layers applied to the masonry walls, it was concluded that only the last step (wall painting using acrylic varnish) reduced the radon emanation, by a factor of approximately 2. Samples of the construction materials (clay bricks and concrete blocks) were ground, homogenized, and subjected to gamma-ray spectrometry analysis to evaluate the activity concentrations of {sup 226}Ra, {sup 232}Th and {sup 40}K. The values for the index of the activity concentration (I), radium equivalent activity (Ra{sub eq}), and external hazard index (H{sub ext}) showed that these construction materials could be used without restrictions or concern about the equivalent dose limit (1 mSv/year). - Highlights: Black-Right-Pointing-Pointer Radon activity in air related to building materials was measured. Black-Right-Pointing-Pointer The index of activity concentration of building materials was evaluated. Black-Right-Pointing-Pointer The radium equivalent activity of

  16. A detailed study of inexpensive radon control techniques in New York state houses

    International Nuclear Information System (INIS)

    Nitschke, I.A.; Wadach, J.B.; Clarke, W.A.; Traynor, G.W.; Adams, G.P.; Rizzuto, J.E.

    1984-01-01

    As part of a comprehensive indoor air quality and infiltration field study, radon concentrations were measured in 60 houses in upstate New York using passive integrating monitors. Indoor air radon concentrations ranged from 0.2 pCi/l to 50 pCi/l. Four houses with the highest radon levels were then extensively monitored using real-time continuous instruments for the measurement of radon, radon daughters, respirable particles, infiltration, inside-outside pressure difference, and weather parameters. Several inexpensive radon mitigation techniques were tested in these four houses. Their effectiveness ranged widely. Techniques identified as effective were permanently installed in 14 houses having indoor air radon concentration above 2 pCi/l. Finally, the long-term effectiveness of the installed control techniques is being tested using passive integrating radon monitors. (Author)

  17. Determination of groundwater flow velocity by radon measurements

    International Nuclear Information System (INIS)

    Hohn, E.; von Gunten, H.R.

    1990-01-01

    The groundwater resources of glacio-fluvial perialpine valleys are recharged significantly by the infiltration from rivers. The groundwater residence times between rivers and wells should be known in groundwater management problems. Short residence times can be estimated using radon. Radon concentrations in rivers are usually very low. Upon filtration and movement of the water in the ground, radon is picked up and its concentration increases by 2-3 orders of magnitude according to radioactive growth laws. Residence times and flow velocities can be estimated from the increasing radon concentrations measured in groundwater sampling tubes at different distances from the river. Results obtained with this method agree with the results from experiments with artificial tracers

  18. Testing of indoor radon-reduction techniques in central Ohio houses: Phase 1 (Winter 1987-1988). Report for October 1987-August 1988 (Final)

    International Nuclear Information System (INIS)

    Findlay, W.O.; Robertson, A.; Scott, A.G.

    1989-07-01

    The U.S. Environmental Protection Agency (EPA) has a program to demonstrate practical, cost-effective methods to reduce indoor radon concentrations in housing to 150 Bq/cu m (4 pCi/L) or less. The complete program will evaluate the full range of radon-reduction methods, i.e., house ventilation, sealing of entry routes, soil ventilation, radon removal from water, and air cleaning in the full range of housing substructure types and building styles, and geological conditions across the continental United States. The program described in the report demonstrated certain radon-reduction methods in housing and geology typical of southern Ohio in particular, and the central Great Plains States in general. The testing of radon-mitigation systems in Ohio houses is envisioned as taking place in two phases. The report describes Phase 1, which was carried out in 16 existing houses in the Dayton area during the 1987-1988 heating season

  19. Radon concentrations in contaminated and uncontaminated premises in two Ontario towns

    International Nuclear Information System (INIS)

    Aitken, J.H.; Baker, E.G.; Chatterjee, R.M.; Kusiak, R.; Tai-Pow, J.

    1977-01-01

    Radon-222 concentrations in air were measured by grab sampling in a large number of private homes and other buildings in the town of Port Hope, Ontario. The purpose of the measurements is to identify places where a health hazard might exist due to improper disposal of radium-contaminated materials. Contaminated fill, rubble, lumber, and other building materials have been found in a number of premises in the town. Radon concentrations up to 750 pCi/l have been found in some homes. The thrust of the program is to identify quickly places where concentrations might be high enough to justify some prompt interim remedial action such as installation of special ventilation systems, pending final remedial work by removal of the contamination. The methods and instrumentation immediately available are those formerly used for radon-in-breath analysis in radium workers. Grab sampling for radon and gamma surveying in every building in town are used together in a screening program. Experience showed that both radon sampling and gamma surveying are required to identify contaminated locations

  20. A Radon Micro Study of Salthill, Galway

    International Nuclear Information System (INIS)

    Boyle-Tobin Ann

    2006-01-01

    This project presents a study of radon gas, when it enters from the ground into the built environment. In order to further inform the present body of knowledge on this potentially dangerous gas, a radon micro study is carried out in the area of Salthill, Galway. A total of 51 households are measured for radon. The results indicate a high variation in the levels recorded, with over a third of the houses measuring above the national safe standard of 200 becquerels per cubic meter, with a small percentage of houses exhibiting very high levels. The results are spatially analysed against the local geology, as radon is a by-product of the breakdown of uranium in rocks. Householders' knowledge and awareness of radon is explored to inform the reasons why more people are not testing their homes for radon, and not installing remedial measures when high levels are detected. The findings indicate significant gaps in householders' knowledge of radon. A certain complacency is noted, which may indicate that people still do not recognise a need to know about this invisible threat. As ways to encourage further testing and remediation levels are equally explored, the government is viewed to play a central role in these processes through partial state funding. Further evidence supports continued and more effective and widespread advertising of radon issues, through all types of media, with emphasis at local level. Incidents of lung cancer and lung disease of long term residents are recorded in an attempt to find out if there is a correlation between them. The results indicate no correlation; however, not all households could participate in this part of the survey as it was limited to long-term residents only

  1. Methodology developed to make the Quebec indoor radon potential map

    International Nuclear Information System (INIS)

    Drolet, Jean-Philippe; Martel, Richard; Poulin, Patrick; Dessau, Jean-Claude

    2014-01-01

    This paper presents a relevant approach to predict the indoor radon potential based on the combination of the radiogeochemical data and the indoor radon measurements in the Quebec province territory (Canada). The Quebec ministry of health asked for such a map to identify the radon-prone areas to manage the risk for the population related to indoor radon exposure. Three radiogeochemical criteria including (1) equivalent uranium (eU) concentration from airborne surface gamma-ray surveys, (2) uranium concentration measurements in sediments, (3) bedrock and surficial geology were combined with 3082 basement radon concentration measurements to identify the radon-prone areas. It was shown that it is possible to determine thresholds for the three criteria that implied statistically significant different levels of radon potential using Kruskal–Wallis one way analyses of variance by ranks. The three discretized radiogeochemical datasets were combined into a total predicted radon potential that sampled 98% of the studied area. The combination process was also based on Kruskal–Wallis one way ANOVA. Four statistically significant different predicted radon potential levels were created: low, medium, high and very high. Respectively 10 and 13% of the dwellings exceed the Canadian radon guideline of 200 Bq/m 3 in low and medium predicted radon potentials. These proportions rise up to 22 and 45% respectively for high and very high predicted radon potentials. This predictive map of indoor radon potential based on the radiogeochemical data was validated using a map of confirmed radon exposure in homes based on the basement radon measurements. It was shown that the map of predicted radon potential based on the radiogeochemical data was reliable to identify radon-prone areas even in zones where no indoor radon measurement exists. - Highlights: • 5 radiogeochemical datasets were used to map the geogenic indoor radon potential. • An indoor radon potential was determined for each

  2. Radiological risk of building materials using homemade airtight radon chamber

    International Nuclear Information System (INIS)

    Norafatin Khalid; Amran Abdul Majid; Redzuwan Yahaya; Muhammad Samudi Yasir

    2013-01-01

    Full-text: Soil based building materials known to contain various amounts of natural radionuclide mainly 238 U and 232 Th series and 40 K. In general most individuals spend 80 % of their time indoors and the natural radioactivity in building materials is a main source of indoor radiation exposure. The internal exposure due to building materials in dwellings and workplaces is mainly caused by the activity concentrations of short lived 222 Radon and its progenies which arise from the decay of 226 Ra. In this study, the indoor radon concentration emanating from cement brick, red-clay brick, gravel aggregate and Portland cement samples were measured in a homemade airtight radon chamber using continuous radon monitor 1029 model of Sun Nuclear. Radon monitor were left in the chamber for 96 hours with an hour counting time interval. From the result, the indoor radon concentrations for cement brick, red-clay brick, gravel aggregate and Portland cement samples determined were 396 Bq m -3 , 192 Bq m -3 , 176 Bq m -3 and 28 Bq m -3 , respectively. The result indicates that the radon concentration in the studied building materials have more than 100 Bq m -3 for example higher than the WHO action level except for Portland cement sample. The calculated annual effective dose for cement brick, red-clay brick, gravel aggregate and Portland cement samples were determined to be 10 mSv y -1 , 4.85 mSv y -1 , 4.44 mSv y -1 and 0.72 mSv y -1 , respectively. This study showed that all the calculated effective doses generated from indoor radon to dwellers or workers were in the range of limit recommended ICRP action levels for example 3 - 10 mSv y -1 . As consequences, the radiological risk for the dwellers in terms of fatal lifetime cancer risk per million for cement brick, red-clay brick, gravel aggregate and Portland cement were calculated to be 550, 267, 244 and 40 persons respectively. (author)

  3. Radiological risk of building materials using homemade airtight radon chamber

    International Nuclear Information System (INIS)

    Khalid, Norafatin; Majid, Amran Ab.; Yahaya, Redzuwan; Yasir, Muhammad Samudi

    2014-01-01

    Soil based building materials known to contain various amounts of natural radionuclide mainly 238 U and 232 Th series and 40 K. In general most individuals spend 80% of their time indoors and the natural radioactivity in building materials is a main source of indoor radiation exposure. The internal exposure due to building materials in dwellings and workplaces is mainly caused by the activity concentrations of short lived 222 Radon and its progenies which arise from the decay of 226 Ra. In this study, the indoor radon concentration emanating from cement brick, red-clay brick, gravel aggregate and Portland cement samples were measured in a homemade airtight radon chamber using continuous radon monitor 1029 model of Sun Nuclear. Radon monitor were left in the chamber for 96 hours with an hour counting time interval. From the result, the indoor radon concentrations for cement brick, red-clay brick, gravel aggregate and Portland cement samples determined were 396 Bq m −3 , 192 Bq m −3 , 176 Bq m −3 and 28 Bq m −3 , respectively. The result indicates that the radon concentration in the studied building materials have more than 100 Bq m −3 i.e. higher than the WHO action level except for Portland cement sample. The calculated annual effective dose for cement brick, red-clay brick, gravel aggregate and Portland cement samples were determined to be 10 mSv y −1 , 4.85 mSv y −1 , 4.44 mSv y −1 and 0.72 mSv y −1 , respectively. This study showed that all the calculated effective doses generated from indoor radon to dwellers or workers were in the range of limit recommended ICRP action levels i.e. 3 - 10 mSv y −1 . As consequences, the radiological risk for the dwellers in terms of fatal lifetime cancer risk per million for cement brick, red-clay brick, gravel aggregate and Portland cement were calculated to be 550, 267, 244 and 40 persons respectively

  4. Observation of radon content in soil gas

    International Nuclear Information System (INIS)

    Mino, Kazuo; Nishimura, Susumu

    1979-01-01

    For earthquake prediction, precursory phenomena before the large earthquakes have been investigated in many countries. In China and some other places, they made a success of predictions of the large earthquakes by catching precursory phenomena. Variation of Radon content of underground gas and water is also one of those phenomena. In our country, the decrease of Radon content was observed several days before the large earthquake which occured near Izu Peninsula on January, 14, 1978. We also begin to observe variation of Radon content of underground gas. The purpose of our observation is a study on the Radon gas content before and after earthquakes. According to the results of the test investigation, the change of atmospheric pressure is mutually related with variation of Radon content in soil gas. Effect of atmospheric pressure is about one Eman, which is significant value comparison with the change, before the large earthquake, a few or several Emans. But, when correction of atmospheric pressure's effect was done, the change of Radon content maybe decrease 5/100 Emans. Above result tells the possibility of detecting the precursor of large earthquake, if Radon content change was over a few Emans. (author)

  5. Residential radon in Kansas City-black shales aren't the prime suspect

    International Nuclear Information System (INIS)

    Spencer, C.G.

    1993-01-01

    The US EPA preliminary assessment of potential radon risk (EPA, 1986) depicted a large area of the mid-continent in which radon levels might be elevated due to the presence of uranium-rich black shales. A preliminary study (Hilpman, Coveney ampersand Spencer, 1988) indicated that a significant percentage of homes in the greater Kansas City area had radon screening levels above 4 pCi/L. However, their lab tests with crushed black shale, and radon tests in limestone mines with black shale floors showed that the shale did not yield extremely high radon levels. This expanded study presents additional results of screening tests in homes, and correlates those results to bedrock geology and soil type. High radon levels in the Kansas city area are not due primarily to black shale sources. The highest readings are associated with limestone and non-organic shale. Mean radon level is higher in younger cyclothemic deposits, and a loessial soil. The EPA initial assessment overstated the radon risk attributable to black uraniferous shale sources. Assessment of the overall potential risk for the greater Kansas City area requires further evaluation of other sources

  6. Radon-hazard potential the Beaver basin, Utah

    International Nuclear Information System (INIS)

    Bishop, C.E.

    1995-01-01

    Indoor-radon levels in the Beaver basin of southwestern Utah are the highest recorded to date in Utah, ranging from 17.5 to 495 picocuries per liter (pCi/L). Because the U.S. Environment Protection Agency considers indoor-radon levels above 4 pCi/L to represent a risk of lung cancer from long-term exposure, the Utah Geological Survey is preparing a radon-hazard-potential map for the area to help prioritize indoor testing and evaluate the need for radon-resistant construction. Radon is a chemically inert radioactive gas derived from the decay of uranium-238, which is commonly found in rocks and soils. Soil permeability, depth to ground water, and uranium/thorium content of source materials control the mobility and concentration of radon in the soil. Once formed, radon diffuses into the pore space of the soil and then to the atmosphere or into buildings by pressure-driven flow of air or additional diffusion. The Beaver basin has been a topographic and structural depression since late Miocene time. Paleocene to Miocene volcanic and igneous rocks border the basin. Uraniferous alluvial-fan, piedmont-slope, flood-plain, and lacustrine sediments derived from the surrounding volcanic rocks fill the basin. A soil-gas radon and ground radioactivity survey in the Beaver basin shows that soils have high levels of radon gas. In this survey, uranium concentrations range from 3 to 13 parts per million (ppm) and thorium concentrations range from 10 to 48 ppm. Radon concentrations in the soil gas ranged from 85 to 3,500 pCi/L. The highest concentrations of uranium, thorium, and radon gas and the highest radon-hazard-potential are in the well-drained permeable soils in the lower flood- plain deposits that underlie the city of Beaver

  7. Monitoring and measurement of radon activity in a new design of radon calibration chamber

    International Nuclear Information System (INIS)

    Heidary, S.; Setayeshi, S.; Ghannadi-Maragheh, M.; Negarestani, A.

    2011-01-01

    A new radon calibration chamber has been designed, constructed and tested to set various desired environmental parameters. The chamber is cubic with two trapezoid sides with a total volume size of 0.498 m 3 . The three parameters, temperature, humidity and flow are controlled in the range of 20-45 deg. C (±2 deg. C), 10-70% (±2.5%) and 0.2-10 m 3 /min (±0.1 m 3 /min) respectively. The chamber is equipped with a controllable speed centrifugal fan to achieve a desirably uniform radon flow rate. Many parts of this system are controlled and monitored with a PLC (Programmable Logic Control) and HMI (Human Monitoring Interface) software (Citect Scada). Finally a radon detector (Alpha-Guard) registers the activity parameter.

  8. Compact detector for radon and radon daughter products

    International Nuclear Information System (INIS)

    Alter, H.W.; Oswald, R.A.

    1986-01-01

    This invention provides an improved compact track registration detector for radon gas. The detector comprises a housing having an open mouth, a bottom, and side walls; track registration means, supported inside the housing, which forms damage tracks along paths traversed by alpha particles; a microporous filter positioned across the mouth of the housing to prevent entry of radon daughters and particulate matter; and a cap that may be placed on the mouth of the housing to retain the filter. The housing has internal wall surfaces dimensioned to optimize the registration of alpha particles from radon and radon daughters present in the housing

  9. Determination of radon in the air of housings of the Aguascalientes municipality

    International Nuclear Information System (INIS)

    Jasso G, M.R.; Lira P, M.G.; Bonilla P, A.; Ruvalcaba S, L.; Gutierrez S, K.M.; Sandoval A, G.E.; Sanchez H, L.

    2006-01-01

    This study reports the results of the first exploratory sampling of the radon concentration in the air in a group of housings of the Aguascalientes City, Mexico. The municipality of Aguascalientes was divided in 4 sampling areas considering a total of 179 housings. In these housings, the radon concentration in the air was monitored during a period of 10 days. The results obtained in this study indicate that the radon concentration in the air of 45% of the sampling housings overcomes the concentration limit of 250 Bq/m 3 suggested by the EPA. (Author)

  10. Investigation of radon-222 emissions from underground uranium mines. Progress report No. 2

    International Nuclear Information System (INIS)

    Jackson, P.O.; Glissmeyer, J.A.; Enderlin, W.I.; Schwendiman, L.C.; Wogman, N.A.; Perkins, R.W.

    1980-02-01

    A reliable estimate of radon emissions to the environment from underground uranium mines was obtained through measurements of radon in ventilation exhaust air at 24 uranium mines and estimates of radon release from ore piles and waste piles at mines and in water pumped from mines. Three additional mines sampled in 1978 but not in 1979 were included in the overall results. Total production of U 3 O 8 from the mines thus far sampled represent about 63% of total 1978 US production from underground mines. Wide variation in radon emission per unit of production was shown from mine to mine; hence, it became necessary to sum all radon from all mines measured and divide by the sum of all U 3 O 8 production in 1978 from these mines to arrive at a valid estimate of Ci per ton of U 3 O 8 . This value was found to be 26.7 per ton or 5400 Ci/RRY (182 metric tons). The radon emitted in mine ventilation air was by far the dominant source, with other than ventilation exhaust sources accounting for less than three percent of radon in ventilation exhaust. Other observations of interest in this study were the diurnal fluctuations of radon with barometric pressure and the statistically significant relationship between radon released per year from a mine and the cumulative ore production at the time of radon measurement. The linear relationship between Ci/yr of radon and cumulative ore accounted for about half the variability.Several sources of random errors and possible biases were evaluated using some simple descriptive statistics insofar as the current data permitted. Errors in air flow rate in the vents sampled, fluctuations in radon emission with time of day, counting instrument calibration and production rate were estimated and combined to give an uncertainty of about +- 24 percent at the 95 percent confidence level

  11. The use of soil gas as radon source in radon chambers

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish

    2009-01-01

    A procedure is described in which soil gas is utilized as an alternative to the 226 Ra source for the supply of the radon gas required to fill a radon chamber where radon-measuring devices are calibrated. The procedure offers opportunities to vary the radon concentration within the chamber around an average value of about 500 Bq/m 3 , which is considered to be sufficient for calibrating indoor radon detectors. The procedure is simple and the radon source does not require radiation protection certification (for import and/or use), unlike the commercially produced standard radioactive ( 226 Ra) sources.

  12. Is environmental radon gas associated with the incidence of neurodegenerative conditions? A retrospective study of multiple sclerosis in radon affected areas in England and Wales

    International Nuclear Information System (INIS)

    Groves-Kirkby, Christopher J.; Denman, Antony R.; Campbell, Jackie; Crockett, Robin G.M.; Phillips, Paul S.; Rogers, Stephen

    2016-01-01

    To test whether an association exists between radon gas concentration in the home and increased multiple sclerosis (MS) incidence, a retrospective study was undertaken of MS incidence in known areas of raised domestic radon concentration in England and Wales, using The Health Improvement Network (THIN) clinical research database. The study population comprised 20,140,498 person-years of clinical monitoring (males: 10,056,628: 49.93%; females: 10,083,870: 50.07%), representing a mean annual population of 2.5 million individuals. To allow for the possible latency of MS initiation following exposure, data extraction was limited to patients with at least five years registration history with the same GP practice before first diagnosis. Patient records were allocated to one of nine radon concentration bands depending on the average radon level in their postcode sector. MS incidence was analysed by searching for patients with first MS diagnosis over the eight calendar years 2005–2012 inclusive. 1512 new MS cases were diagnosed, 1070 females, 442 males, equivalent to raw incidence rates of 7.51, 10.61 and 4.40 per 10 5 person-years respectively, comparable to previously reported results. Of these new cases, 115 could be allocated to one of the radon bands representing high radon areas. Standardising to the UK 2010 population, excess relative risk (ERR) figures for MS were calculated for each radon band. Linear regression of ERR against mean band radon concentration shows a positive gradient of 0.22 per 100 Bq·m −3 (R 2  = 0.25, p = 0.0961) when forced through the origin to represent a linear-no-threshold response. The null hypothesis falls inside the 95% confidence interval for the linear fit and therefore this fit is not statistically significant. We conclude that, despite THIN sampling around 5% of the population, insufficient data was available to confirm or refute the hypothesised association between MS incidence and radon concentration. - Highlights:

  13. The optimation of radon-222 determination in water by Lucas cell technique

    International Nuclear Information System (INIS)

    Andrejkovicova, S.; Kuruc, J.; Kovacsova, A.; Mackova, J.; Rajec, P.

    2003-01-01

    The aim of this work was to determine detection efficiency ε, volume activity a v , low detection limit, minimal detection activity for radon. There were collecting several samples of water: water from tap water, mineral water, thermal water, water from wells and bottled drinking water. As we expected, the lowest values of volume activities of radon were reached in bottled drinking water (0.1 - 4.9 Bq/dm 3 ). Higher values were reached in water from tap water and natural mineral water (2.5 - 14.9 Bq/dm 3 ). The highest volume activities of radon were obtained in thermal water and water from wells (17.2 - 107.9 Bq/dm 3 ). Method for determination of radon in water was verified at Institute of Preventive and Clinical Medicine, Bratislava, Slovakia. Results of radon concentration in waters are in accordance with an uppermost - accepted value of radon in water. The volume activity of radon in our samples has never been higher as a limit value has allowed (300 Bq/dm 3 ). (authors)

  14. Radon measurement waters from different regions of Transylvania

    International Nuclear Information System (INIS)

    Moldovan, M.; Cosma, C.

    2004-01-01

    Radon exposure is still a very current problem in the scientific world. It is well-known that 222 Rn and its short-lived daughters contribute to the effective dose equivalent, through inhalation, in a percent of 50% of the total effective dose equivalent from natural sources [UNSCEAR, 1988]. The radon gas incorporated in water is transferred into the indoor air by simple utilisation of water for domestic purposes. According to the American standards, the waters with concentrations of radon higher than 11.11 Bq/l (300 pCi/l) must not be consumed. Radon studies are very motivated even from the medical and geophysical point of view. Moreover, interesting correlations can be done between the measured concentration indoors and the concentration of those underground waters that supply them. We measured over 135 samples of groundwater. These were collected from wells, at different depths. The samples were measured after 12 hours, in order to prevent the radon loss. For groundwater measurements we used, a device called LUK-3A, manufactured in Czech Republic, which has a standard deviation of ± 10% and a sensibility of 0.56 Bq/l (15 pCi/l).The method is based on the detection of alpha radioactivity of 222 Rn. It can be set to perform measurements of 222 Rn from water. In case of this method a water sample of 0.3 l is collected into a glass container which is intensely stirred and shaken for one minute. The container is then connected to a vacuumed Lucas cell on one side and on the other side connected to a syringe in which distillated water was introduced having an amount equal to the volume of gas left into the collector container. Three successive measurements of 100 s were made for each sample. Before starting the measurements the background of the Lucas cells that were going to be used was determined. The concentration of radon is calculated using the formula: C Rn = k · N [Bq/l] where k - calibration constant, k = 9.85; N - count of pulses recorded in 100 minutes

  15. Radon in Antarctica

    International Nuclear Information System (INIS)

    Ilic, R.; Rusov, V.D.; Pavlovych, V.N.; Vaschenko, V.M.; Hanzic, L.; Bondarchuk, Y.A.

    2005-01-01

    The paper reviews results of radon measurements obtained in Antarctic research stations in the last 40 years by both active and passive radon monitors. A brief description of the radon laboratory set-up in the Ukrainian Academician Vernadsky station on the Antarctic Peninsula (W 64 o 16 ' , S 65 o 15 ' ), where radon is measured by two types of etched track Rn dosimeter and 4 types of continuous radon monitoring devices is presented. Some selected results of research work are described related to: (i) analysis of radon storms, defined as an abrupt increase of 222 Rn during the occurrence of a cyclone, and its applicability for the study of the transport of air masses of continental origin to Antarctica; (ii) a study of the correlation of changes of radon concentration and geomagnetic field induced by tectonic activity and its application to predicting tectonomagnetic anomalies, and (iii) verification of a newly developed theoretical model based on noise analysis of the measured radon signal for earthquake prediction. Suggestions for future utilization of radon for basic research in Antarctica (and not only in Antarctica) conclude the contribution. conclude the contribution

  16. Radon assessment in thermal waters in Imbabura and Pichincha provinces

    International Nuclear Information System (INIS)

    Aragon, Mayra

    2001-01-01

    The radon is a radioactive, odorless and colorless gas, that generated in the terrestrial crust by the radioactive decay of the radio, originating of the chain of disintegration of the Uranium-238, can migrate considerable distances during its short time of life (3.82 days), from the ground to the water and later to the atmosphere. For the accomplishment of the preliminary study of quantification of radon in thermal sources, it was come to the sampling from radon-222 in bath waters different from the provinces of Pichincha and Imbabura. For which a particle accountant was used alpha, that uses the method of flashing, emitted by ionizing particles at the moment at which the radium decays in its descendant radon, and this one in its next descendants. The water samples are analyzed in the Pylon model RM-1003, particle accountant alpha, that uses for the harvesting of the gas, cameras that contain sensible detectors activated zinc sulfide cells with silver. For this sampling it was taken into account qualitative factors like: rain temperature, presence, origin of the source, proximity of some hill or volcano, presence of seismic movements, among others. These parameters could affect to the measurements of concentration of radon. Of the obtained results, we can conclude that of the 13 bath, those of the province of Pichincha, specially three of them (Tesalia, Sillunchi, Cunuyacu), contain greater concentration of radon that those of the province of Imbabura. In addition in general for all the selected bath it was verified that the concentration of radon is greater for the source than for the swimming pool. Finally it is possible to be emphasized values of concentration of radon that are around 1000-15000 Bq/m3 for the source, and the swimming pool of 100-800 Bq/m3. (The author)

  17. Radon-Instrumentation; Radon-Instrumentacion

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, 4 Sur 104, Centro Historico 72000 Puebla (Mexico)

    2003-07-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  18. Long-term measurement of radon concentration in the family house

    International Nuclear Information System (INIS)

    Muellerova, M.; Holy, K.

    2009-01-01

    The aim of this report was monitored the family house with radon concentration above radon limit for inhabited areas during one year. We were studied radon concentration changes in different rooms this house. Knowledge concerning of variations of radon activity concentration in family house were obtained. Daily variations show a maximum in the morning and a minimum in the afternoon. The seasonal variations show a minimum in spring months (March -April) and a maximum in early autumn (September). The radon concentration in the upstairs room was similar but ten-times lower than radon concentration in the downstairs room. In next period, the obtained results will be analysed in detail and different model describing the behaviour of radon in indoor air will be tested too. (authors)

  19. Natural radioactivity content and radon exhalation from materials used for construction and decoration

    International Nuclear Information System (INIS)

    Ngachin, M.; Garavaglia, M.; Giovani, C.; Scruzzi, E.; Kwato Njock, M.G.; Nourreddine, A.

    2007-02-01

    The present work deals with the measurement of radioactivity and radon exhalation rate from geological samples manufactured in Douala city and used as building materials. Nine types of building materials were surveyed for their natural radioactivity content using a hyper purity germanium (HPGe) detector. The absorbed dose rate in the samples investigated ranged from 28.5 to 66.6 nGy h -1 for brick samples, from 32.4 to 63.1 nGy h -1 for roofing tiles and was 30.3 nGy h -1 for concrete. External and internal hazard indexes were also estimated as defined by the European Commission. The study of radon exhalation rate from building materials is important for well understanding the individual contribution of each material to the total indoor radon exposure. Solid state nuclear track detectors, CR-39 were used for measuring the radon concentration from different materials. Samples were hermetically closed in glass vessels and the radon growth was followed as a function of time. Exploring the one-dimension radon transport equation, we derived the radon exhalation rate from the experimental measurement of α-track densities. The radon exhalation varied from (5.77±0.06) x 10 -5 to (7.61±0.07) x 10 -5 Bq cm -2 h -1 in bricks, from (5.79±0.05) x 10 -5 to (11.6±0.12) x 10 -5 in tiles and was (6.95±0.03) x 10 -5 Bq cm -2 h -1 in concrete. A positive correlation was found between uranium concentration measured with HPGe detector radon exhalation rate and radium content obtained using nuclear track detectors. (author)

  20. Track-etch detection of radon in soils

    International Nuclear Information System (INIS)

    Cervantes Gonzales, P.; Gonzalez, D.

    1990-01-01

    In this work it is described the methodology to apply the track-etch technique, using detectors of nitrocellulose LR-115, for the detection of radon in soil. It is supported the use of the new detector carries and determined the parameters for revealing and counting of tracks in our conditions. It is shown in a preliminary way that this method gives better possibilities for analysis than another traditional technique to radon detection. The existence of radon was determined in the test zone. 15 refs

  1. Radon-enriched spring waters in the South of Poland

    International Nuclear Information System (INIS)

    Kozlowska, B.; Hetman, A.; Dorda, J.; Zipper, W.

    2001-01-01

    A method for determination of 222 Rn in natural water samples which involves a Wallac 1414 Win Spectral α/β liquid scintillation counter is described. Samples were collected from springs in health resorts in the Sudety Mountains in Poland. Half of the studied water samples were radon enriched with an activity concentration higher then 74 Bq/l. Seasonal variations of 222 Rn in these waters are under investigation. The method introduced is very convenient and elegant for radon activity measurements.

  2. A study of radon 222 permeation through plastic membranes. Application to a method of radon measurement in water and saturated soils

    International Nuclear Information System (INIS)

    Labed, V.

    1991-04-01

    In order to improve the BARASOL R device and to use it in water-saturated soils and in pressure constraint conditions, we have studied radon 222 permeation through plastic membranes. While the permeation process usually takes place between two media being in the same state, most often gaseous, the present study describes the transfer of radon 222 from the water to the air via a membrane. Polypropylene membranes have been tested with an experimental set-up by monitoring the evolution of radon concentrations in water and in air. The permeation coefficient and the activation energy were calculated in various conditions. With a second experimental set-up, we have tested the polyethylene membrane which has been adapted on the BARASOL. In these conditions, we have shown that it is possible to measure radon in water at concentrations around 10 3 Bq.m -3 [fr

  3. Cornerstones of the Austrian radon risk communication strategy

    International Nuclear Information System (INIS)

    Kunte, A.; Ringer, W.

    2015-01-01

    On behalf of the Federal Ministry of Agriculture, Forestry, Environment and Water Management (BMLFUW), the National Radon Centre of Austria developed the National Radon Risk Communication Strategy. The superior goal is the reduction of the radon exposure of Austrian citizens as well as the reduction of radon-related lung cancer deaths. Austria, like many other countries, follows the approach to raise awareness and to inform the public to achieve this goal. The presented strategy deals with the question of how radon protection issues can be communicated to the public, existing fears can be reduced and affected people can be motivated to take action (perform a radon test, if necessary, mitigate or install preventive measures in new buildings). The cornerstones of the National Radon Risk Communication Strategy can be summarized as follows: - Definition of communication goals - Identification and categorization of target groups - Development of specific key messages for each of the target groups - Determination of communication channels and assessment of their efficiency - Integration of the radon issue in education and training - Cooperation with relevant organizations and platforms. The communication objectives, target groups and communication paths (and their evaluation) will be discussed during the presentation in detail.

  4. Developmental toxicology of radon exposures

    International Nuclear Information System (INIS)

    Sikov, M.R.; Cross, F.T.; Mast, T.J.; Palmer, H.E.; James, A.C.; Thrall, K.D.

    1992-01-01

    Concerns about hazards associated with radon exposure in dwellings may be especially relevant to pregnant women, many of whom spend substantial amounts of time in their homes. There are few data concerning the placental transfer and fetoplacental distribution of inhaled radon and decay products or their effects on the conceptus. We performed a study in rats to determine if prenatal effects could be produced by prolonged inhalation exposures to high concentrations of radon throughout gestation. A group of 43 pregnant rats was exposed 18 h d -1 , at a rate of 124 working level months (WLM) per day, from 6 to 19 days of gestation (dg), of radon and daughters adsorbed onto ore dust. A group of 26 pregnant rats from the same shipment was exposed to a filtered-air atmosphere as controls. At 20 dg, the rats were removed from the chambers, killed, and necropsied. The fetuses were evaluated for the presence of toxic effects, which included detailed teratology protocols. These exposures did not produce detectable reproductive toxicity nor teratogenic change. Two other rats were removed from the radon chambers during the last day of exposure, and their tissues were analyzed to determine the distribution of radioactivity and for dosimetry. Samples from these rats suggested that the dose rates to the placenta were roughly threefold those to the fetus but were similar to those to the liver and femur of the pregnant rats. These data indicate that the dose to the conceptus from the decay of placentally transferred radon and its progeny is more important than the contribution of translocated decay products. Translocated radon decay products are an important source of radiation doses to placental structures, however, and may have most of the radioactivity content at birth

  5. Indoor radon levels in schools of South-East Italy

    International Nuclear Information System (INIS)

    Trevisi, Rosabianca; Leonardi, Federica; Simeoni, Carla; Tonnarini, Sabrina; Veschetti, Miriam

    2012-01-01

    A survey was conducted to evaluate average levels of indoor radon and gamma doses in all educational buildings (506 schools) located in South-East Italy (the Salento peninsula, province of Lecce). In this paper the final findings relating to measurements performed with SSNTD dosemeters in 438 schools (86% of the sample) are reported. The average annual activity concentration of radon in schools located in the province of Lecce is 209 ± 9 Bq/m 3 . Radon values actually ranged from 21 Bq/m 3 to 1608 Bq/m 3 . About 7% of schools showed radon concentration values above 500 Bq/m 3 , the Italian action level for workplaces. - Highlights: ► The annual radon concentration in schools of the province of Lecce is 209 ± 9 Bq/m 3 . ► Schools radon values (209 ± 9 Bq/m 3 ) are higher than the regional average (52 ± 2 Bq/m 3 ). ► Nursery schools showed higher radon values. ► Nursery schools had the highest percentage of schools (12%) over 500 Bq/m 3 .

  6. High radon exposure in a Brazilian underground coal mine

    International Nuclear Information System (INIS)

    Veiga, L H S; Melo, V; Koifman, S; Amaral, E C S

    2004-01-01

    The main source of radiation exposure in most underground mining operations is radon and radon decay products. The situation of radon exposure in underground mining in Brazil is still unknown, since there has been no national regulation regarding this exposure. A preliminary radiological survey in non-uranium mines in Brazil indicated that an underground coal mine in the south of Brazil had high radon concentration and needed to be better evaluated. This paper intends to present an assessment of radon and radon decay product exposure in the underground environment of this coal mining industry and to estimate the annual exposure to the workers. As a product of this assessment, it was found that average radon concentrations at all sampling campaign and excavation sites were above the action level range for workplaces of 500-1500 Bq m -3 recommended by the International Commission on Radiological Protection-ICRP 65. The average effective dose estimated for the workers was almost 30 times higher than the world average dose for coal miners

  7. Determination of radon exhalation rates from tiles using active and passive techniques

    International Nuclear Information System (INIS)

    Al-Jarallah, M.I.; Abu-Jarad, F.; Fazal-ur-Rehman

    2001-01-01

    Measurements of radon exhalation rates for selected samples of tiles used in Saudi Arabia were carried out using active and passive measuring techniques. These samples were granite, marble and ceramic. In the active method, a PC-based radon gas analyzer with emanation container was used, while, in the passive method, PM-355 nuclear track detectors with the 'can technique' were applied for 180 days. A comparison of the exhalation rates measured by the two techniques showed a good linear correlation coefficient of 0.7. The granite samples showed an average radon exhalation rate of 0.7 Bq m -2 h -1 , which was higher than that of marble and ceramic by more than twofold. The radon exhalation rates measured by the 'can technique' showed a non-uniform exhalation from the surface of the same tile

  8. From insulation contracting to radon mitigation

    International Nuclear Information System (INIS)

    West, D.R.

    1990-01-01

    As the definition of house doctor has evolved over the past ten years and the field of energy services has grown more sophisticated, many contractors have expanded the services they offer their clients. This paper presents the story of one insulation contractor who has found a niche in radon testing and mitigation. The EPA now has a national program for the radon mitigator called the Radon Contractor Proficiency Program. The requirements include attending the Radon Technology for Mitigators course, passing an exam, and taking continuing education. In the Midwest, the most popular mitigation technique is the subslab depressurization system. To draw suction from under the slab, the system can take advantage of an existing sump crock or can penetrate the slab. Interior drain tiles collect water to empty into the crock, providing an excellent pathway to draw from. This mitigation process is explained

  9. Intercomparison of different instruments for measuring radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Iida, Takao

    1990-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap method, a flow-type ionization chamber (pulse-counting method), a two-filter method, an electrostatic collection method and a passive integration radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq·m -3 (in outdoor air) to 110 Bq·m -3 (in indoor air). The results obtained by these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling method was about 52% of radon concentration. (author)

  10. Intercomparison of different instruments that measure radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, M.; Iida, T.; Ikebe, Y.

    1987-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap technique, a flow-type ionization chamber (pulse-counting technique), a two-filter method, an electrostatic collection method and a passive integrating radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq/m/sup 3/ (in outdoor air) to 110 Bq/m/sup 3/ (in indoor air). The results obtained from these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling technique was about 52% of radon concentrations

  11. Systematic effects in radon mitigation by sump/pump remediation

    International Nuclear Information System (INIS)

    Groves-Kirkby, C.J.; Denman, A.R.; Groves-Kirkby, C.J.; Woolridge, A.C.; Woolridge, A.C.; Phillips, P.S.; Crockett, R.G.M.; Tornberg, R.

    2006-01-01

    Sump/Pump remediation is widely used in the United Kingdom to mitigate indoor radon gas levels in residential properties. To quantify the effectiveness of this technology, a study was made of radon concentration data from a set of 173 homes situated in radon Affected Areas in and around Northamptonshire, U.K., re-mediated using conventional sump/pump technology. This approach is characterised by a high incidence of satisfactory mitigation outcomes, with more than 75% of the sample exhibiting mitigation factors (defined as the ratio of radon concentrations following and prior to remediation) of 0.2 or better. There is evidence of a systematic trend, where houses with higher initial radon concentrations have higher mitigation factors, suggesting that the total indoor radon concentration within a dwelling can be represented by two components, one susceptible to mitigation by sump/pump remediation, the other remaining essentially unaffected by these remediation strategies. The first component can be identified with ground-radon emanating from the subsoil and bedrock geologies, percolating through the foundations of the dwelling as a component of the soil-gas, potentially capable of being attenuated by sump/pump or radon-barrier remediation. The second contribution is attributed to radon emanating from materials used in the construction of the dwelling, principally concrete and gypsum plaster-board, with a further small contribution from the natural background level, and is essentially unaffected by ground-level remediation strategies. Modelling of such a two-component radon dependency using realistic ground-radon attenuation factors in conjunction with typical structural-radon levels yields behaviour in good agreement with the observed inverse-power dependence of mitigation factor on initial radon concentration. (authors)

  12. Radon programme: presence and future

    International Nuclear Information System (INIS)

    Hulka, J.

    2009-01-01

    In this presentation an overview of radon programme experiences is presented. The paper summarises national radon policy, national programmes, legislation, the role of preventive measures and interventions with respect to existing and future exposure and knowledge of radon risk, problems of remediation strategies, practical protection in dwellings, radon measurements strategies, progress in radon measurement of an individual house (radon diagnosis), radon mapping process and sense of delineation of radon prone areas, natural radioactivity of building materials and radioactivity in public water and their role in the radon programme, public awareness on radon issue and publicity campaign. Some research activities are proposed aiming at effective solutions of radon issues in future

  13. Residential radon daughter monitor based on alpha spectroscopy

    International Nuclear Information System (INIS)

    Nazaroff, W.W.

    1980-05-01

    The radioactive daughters of radon-222 pose a serious indoor air quality problem in some circumstances. A technique for measuring the concentrations of these radioisotopes in air is presented. The method involves drawing air through a filter; then, for two time intervals after sampling, counting the alpha decays from polonium-218 and polonium-214 on the filter. The time intervals are optimized to yield the maximum resolution between the individual daughter concentrations. For a total measurement time of 50 minutes, individual daughter concentrations of 1.0 nanocuries per cubic meter are measured with an uncertainty of 20%. A prototype of a field monitor based on this technique is described, as is a field test in which the prototype was used to measure radon daughter concentrations as a function of ventilation conditions in an energy-efficient house

  14. Radon

    International Nuclear Information System (INIS)

    1990-01-01

    This leaflet in the At-a-Glance Series, describes what radon is, where it is found, why it presents a risk to health, the official advice, and the remedies that are available to reduce radon levels. (author)

  15. Project radon final report

    International Nuclear Information System (INIS)

    Ekholm, S.; Rossby, U.

    1990-01-01

    The main radiation problem in Sweden is due to radon in dwellings. At the Swedish State Power Board, R, D and D about radon has been going on since 1980. The work has concentrated on the important questions: How to find building with enhanced radon levels?; How to accurately decide on measures that will give adequate cleaning-up results, using appropriate measurement procedures; What cleaning-up effect is possible to achieve with an electro-filter?; and What cleaning-up effects are possible to achieve with different types of ventilation systems? The R, D and D-work, has been pursued in cooperation with universities of technology in Denmark and Finland, equipment manufacturers, consultants and authorities concerned. It was decided in December 1986 to give an offer to some SSPB-employees to investigate the radon situation of their dwellings, in order to test methods of measurement and cleaning-up under realistic conditions and to develop the methods to commercial maturity. The investigation was named 'Project Radon' and was carried out in three years with costs amounting to 1 M dollars. During the project less comprehensive radon measurements, named 'trace-measurements' were undertaken in about 1300 dwellings and more elaborate measurements, leading to suggestions of actions to be taken, in about 400 dwellings. Out of the suggestions, about 50 are carried out including control measurement after actions taken. The control measurement have shown that the ability to suggest appropriate actions is very successful - in just one case was a minor additional action necessary. The high reliability is achieved by always doing elaborate measurements before suggested mitigation method is decided on. (authors)

  16. Radon and thoron progeny measurements using a portable radon sniffer

    International Nuclear Information System (INIS)

    Efendi, Z.; Jennings, P.

    1993-01-01

    A flexible version of the two-count method has been developed for use in rapid, inexpensive measurements of radon and thoron progeny working levels in residential and industrial premises in the Perth Metropolitan Area. The Method is adapted for use with a simple radon sniffer based on a low speed pump and an alpha counter. The flexibility of the method derives from the software, where some freedom is permitted in the selection of sampling times and post sampling analysis of the filters. This method has been tested on a variety of radioactive materials and it gives consistent, reliable results over a wide range of working levels. The results of a survey of Rn(222) and Rn(220) progeny levels in dwellings within the Perth Metropolitan Area are reported. This study shows that the mean concentration of indoor Rn(222) progeny was 4.7 mWL (17.4 Bq m -3 EEC) up to 23.3 mWL (86.4 Bq m -3 EEC). The mean thoron progeny concentration was 8.2 mWL (2.25 Bq m -3 EEC) with a range from 1 mWL (0.27 Bq m -3 EEC) to 64.5 mWL (17.74 Bq m -3 EEC). Using conversion factors of 0.061 mSv Bq -1 m -3 for Rn(222) progeny and 0.29 mSv Bq -1 m -3 for Rn(220) progeny respectively (UNSCEAR, 1982), it is estimated the average annual effective dose equivalent is 1.1 mSv for Rn(2220 and 0.6 mSv for Rn(220) respectively. 22 refs., 4 tabs., 1 fig

  17. Biological effects of radon in Drosophila

    International Nuclear Information System (INIS)

    Pimentel P, A.E.; Tavera D, L.; Cruces M, M.P.; Arceo M, C.; Rosa D, M.E. de la

    1992-04-01

    The main objective of this investigation, is to study the biological effects of the Radon-222 at low dose in 'Drosophila melanogaster'. It is necessary to mention that these effects will analyze from the genetic point of view for: 1) To evaluate in which form the Radon-222 to low dose it influences in some genetic components of the adaptation in Drosophila, such as: fecundity, viability egg-adult and sex proportion. 2) To evaluate which is the genetic effect that induces the Radon to low dose by means of the SMART technique in Drosophila melanogaster, and this way to try of to identify which is the possible mechanism that causes the genetic damage to somatic level. The carried out investigation was divided in three stages: 1. Tests to the vacuum resistance. 2. Test of somatic mutation, and 3. Determination of the presence of radon daughters on the adult of Drosophila. It is necessary to point out that all the experiments were made by triplicate and in each one of them was placed detectors in preset places. Those obtained results are presented inside the 4 charts included in the present work. (Author)

  18. Survey of radon concentrations in three Italian towns

    International Nuclear Information System (INIS)

    Malanca, A.; Pessina, V.; Dallara, G.

    1992-01-01

    Radon-222 was measured in 187 dwellings in Parma, Reggio Emilia, and Orvieto. Samples were collected using activated carbon canisters, placed in basements and on the upper floors for at least 48 h in the period starting from January 1989 to July 1990. Gamma spectroscopy was used for the measurement of 222 Rn and its progeny. The data for the three towns show a lognormal distribution. Owing to the high radium concentration in building materials and underlying soil, high radon concentrations were observed in Orvieto's dwellings. Additional measurements carried out in 22 public schools of Parma and Reggio Emilia showed moderate radon concentrations, while significant radon levels were recorded in 37 castles and ancient buildings in Parma and Reggio Emilia provinces

  19. Natural radioactivity and radon specific exhalation rate of zircon sands

    International Nuclear Information System (INIS)

    Righi, S.; Verita, S.; Bruzzi, L.; Albertazzi, A.

    2006-01-01

    The study focuses on the radon emanation from zircon sands and their derivatives, which are widely used in many sectors of industry. In particular, the results obtained by experimental measurements on samples of zircon sands and zircon flours commonly used in Italian ceramic industries are reported. Zircon sands contain a significant concentration of natural radioactivity because Th and U may substitute zirconium in the zircon crystal lattice. The relevant routes of exposure of workers to T.E.N.O.R.M. from zircon materials are external radiation and internal exposure, either by inhalation of aerosols in dusty working conditions or by inhalation of radon in workplaces. The main objective of this investigation is to provide experimental data able to better calculate the internal exposure of workers due to radon inhalation. Zircon samples were surveyed for natural radioactivity, radon specific exhalation rate and emanation fraction. Measurements of radioactivity concentration were carried out using γ-spectrometry. Methods used for determining radon consisted in determining the 222 Rn activity accumulated in a vessel after a given accumulation build-up time. The average activity concentrations of 238 U and 232 Th in samples result about 2600 and 550 Bq kg-1, respectively; these concentrations are significantly higher than the world average noticed in soils, rocks and Earth crust. The 222 Rn specific exhalation rates result very low probably due to the low porosity of the material and the consequent difficulty for radon to be released from the zircon crystal lattice. (author)

  20. Sorption of radon-222 to natural sediments

    International Nuclear Information System (INIS)

    Wong, C.S.; Chin, Y.P.; Gschwend, P.M.

    1992-01-01

    The sorption of radon to sediments was investigated, since this may affect the use of porewater radon profiles for estimating bed irrigation rates. Batch experiments showed that radon has an organic-carbon-normalized sediment-water partition coefficient (K oc , L kg oc -1 ) of 21.1 ± 2.9 for a Boston Harbor sediment, 25.3 ± 2.1 for a Charles River sediment, and 22.4 ± 2.6 for a Buzzards Bay sediment. These values are in close agreement with predictions using radon's octanol-water partition coefficient (K ow ), which was measured to be 32.4 ± 1.5. Temperature and ionic strength effects on K oc were estimated to be small. Given rapid sorption kinetics, the authors suggest that slurry stripping techniques used by many investigators to measure 222 Rn in sediment samples collect both sorbed and dissolved radon. Sorption effects were included in a transport model to obtain revised estimates of irrigation rates from existing literature profiles. Irrigation rates had to be increased over previously reported values in proportion to the sediment organic matter content

  1. Measurement of radon permeability through polyethylene membrane using scintillation detector

    Energy Technology Data Exchange (ETDEWEB)

    Ashry, A.H.; Abou-Leila, M. [Department of Physics, Faculty of Education, Ain Shams University, Cairo (Egypt); Abdalla, A.M., E-mail: aymanabdalla62@hotmail.co [Department of Physics, Faculty of Education, Ain Shams University, Cairo (Egypt); Department of Physics, Faculty of Sciences and Arts, Najran University, Najran, P.O. Box. 11001 (Saudi Arabia); Advanced Materials and Nano-Engineering Laboratory (AMNEL), Centre for Advanced Materials and Nano-Engineering (CAMNE), Najran University, Najran, P.O. Box. 11001 (Saudi Arabia)

    2011-01-15

    The permeability of Radon 222 through polyethylene membranes has been studied using activated charcoal technique. The permeability constant of Radon 222 through low-density polyethylene, linear low-density Polyethylene and high density polyethylene samples has been measured. There is a considerable agreement between the values obtained by our method and the method suggested by W. Arafa [2002. Permeability of radon 222 through some materials. Radiat. Meas. 35, 207-211], and SSNTD technique suggested by A. Hafez and G. Somogyi [1986. Determination of radon and thoron permeability through some plastics by track technique. Int. J. Radiat. Appl. Instrum. Nucl. Track Radiat. Meas. 12 (1-6), 697-700]. In this work Radon permeability through different polyethylene membranes has been measured using three different methods, i.e. solid state nuclear track technique, W. Arafa [2002. Permeability of radon 222 through some materials. Radiat. Meas. 35, 207-211]method and our proposed method. In addition to this, in this study, the diffusion coefficient of radon in charcoal as well as solubility of Radon in polyethylene membrane has been taken into consideration.

  2. Measurement of radon permeability through polyethylene membrane using scintillation detector

    International Nuclear Information System (INIS)

    Ashry, A.H.; Abou-Leila, M.; Abdalla, A.M.

    2011-01-01

    The permeability of Radon 222 through polyethylene membranes has been studied using activated charcoal technique. The permeability constant of Radon 222 through low-density polyethylene, linear low-density Polyethylene and high density polyethylene samples has been measured. There is a considerable agreement between the values obtained by our method and the method suggested by W. Arafa [2002. Permeability of radon 222 through some materials. Radiat. Meas. 35, 207-211], and SSNTD technique suggested by A. Hafez and G. Somogyi [1986. Determination of radon and thoron permeability through some plastics by track technique. Int. J. Radiat. Appl. Instrum. Nucl. Track Radiat. Meas. 12 (1-6), 697-700]. In this work Radon permeability through different polyethylene membranes has been measured using three different methods, i.e. solid state nuclear track technique, W. Arafa [2002. Permeability of radon 222 through some materials. Radiat. Meas. 35, 207-211] method and our proposed method. In addition to this, in this study, the diffusion coefficient of radon in charcoal as well as solubility of Radon in polyethylene membrane has been taken into consideration.

  3. Radon emanation chamber: High sensitivity measurements for the SuperNEMO experiment

    Energy Technology Data Exchange (ETDEWEB)

    Soulé, B. [Université Bordeaux 1, Centre d' Etudes Nucléaires de Bordeaux Gradignan, UMR 5797, Chemin du Solarium, Le Haut-Vigneau, BP120, F-33175 Gradignan (France); Collaboration: SuperNEMO Collaboration; and others

    2013-08-08

    Radon is a well-known source of background in ββ0ν experiments due to the high Q{sub β} value of one of its daughter nucleus, {sup 214}Bi. The SuperNEMO collaboration requires a maximum radon contamination of 0.1 mBq/m{sup 3} inside its next-generation double beta decay detector. To reach such a low activity, a drastic screening process has been set for the selection of the detector's materials. In addition to a good radiopurity, a low emanation rate is required. To test this parameter, a Radon Emanation Setup is running at CENBG. It consists in a large emanation chamber connected to an electrostatic detector. By measuring large samples and having a low background level, this setup reaches a sensitivity of a few μ Bq. m{sup −2}. d{sup −1} and is able to qualify materials used in the construction of the SuperNEMO detector.

  4. The radon monitoring system in Daya Bay Reactor Neutrino Experiment

    International Nuclear Information System (INIS)

    Chu, M.C.; Kwan, K.K.; Kwok, M.W.; Kwok, T.; Leung, J.K.C.; Leung, K.Y.; Lin, Y.C.; Luk, K.B.; Pun, C.S.J.

    2016-01-01

    We developed a highly sensitive, reliable and portable automatic system (H 3 ) to monitor the radon concentration of the underground experimental halls of the Daya Bay Reactor Neutrino Experiment. H 3 is able to measure radon concentration with a statistical error less than 10% in a 1-h measurement of dehumidified air (R.H. 5% at 25 °C) with radon concentration as low as 50 Bq/m 3 . This is achieved by using a large radon progeny collection chamber, semiconductor α-particle detector with high energy resolution, improved electronics and software. The integrated radon monitoring system is highly customizable to operate in different run modes at scheduled times and can be controlled remotely to sample radon in ambient air or in water from the water pools where the antineutrino detectors are being housed. The radon monitoring system has been running in the three experimental halls of the Daya Bay Reactor Neutrino Experiment since November 2013.

  5. Indoor and soil radon measurements in the Hyblean Foreland (South-East Sicily

    Directory of Open Access Journals (Sweden)

    G. Alessandro

    2007-06-01

    Full Text Available Indoor radon behavior in two sites of SE Sicily was studied as a function of the soil radon concentration. The chosen locations were Ragusa and Modica towns, placed in the Hyblean Plateau (northern margin of the African Plate. Soil samples were analysed by gamma spectrometry to determine the amount of radionuclides. Indoor air and soil gas radon measurements were simultaneously performed in both sites using active detectors. Radon in soil was measured one meter deep. A positive correlation was obtained between indoor radon concentration and the soil gas concentration.

  6. Methodology developed to make the Quebec indoor radon potential map

    Energy Technology Data Exchange (ETDEWEB)

    Drolet, Jean-Philippe, E-mail: jean-philippe.drolet@ete.inrs.ca [Institut national de la recherche scientifique, Eau Terre Environnement Research Centre (ETE-INRS), 490 de la Couronne, G1K 9A9 Quebec (Canada); Martel, Richard [Institut national de la recherche scientifique, Eau Terre Environnement Research Centre (ETE-INRS), 490 de la Couronne, G1K 9A9 Quebec (Canada); Poulin, Patrick [Institut national de santé publique du Québec (INSPQ), 945 avenue Wolfe, G1V 5B3 Quebec (Canada); Dessau, Jean-Claude [Agence de la santé et des services sociaux des Laurentides, 1000 rue Labelle, J7Z 5 N6 Saint-Jérome (Canada)

    2014-03-01

    This paper presents a relevant approach to predict the indoor radon potential based on the combination of the radiogeochemical data and the indoor radon measurements in the Quebec province territory (Canada). The Quebec ministry of health asked for such a map to identify the radon-prone areas to manage the risk for the population related to indoor radon exposure. Three radiogeochemical criteria including (1) equivalent uranium (eU) concentration from airborne surface gamma-ray surveys, (2) uranium concentration measurements in sediments, (3) bedrock and surficial geology were combined with 3082 basement radon concentration measurements to identify the radon-prone areas. It was shown that it is possible to determine thresholds for the three criteria that implied statistically significant different levels of radon potential using Kruskal–Wallis one way analyses of variance by ranks. The three discretized radiogeochemical datasets were combined into a total predicted radon potential that sampled 98% of the studied area. The combination process was also based on Kruskal–Wallis one way ANOVA. Four statistically significant different predicted radon potential levels were created: low, medium, high and very high. Respectively 10 and 13% of the dwellings exceed the Canadian radon guideline of 200 Bq/m{sup 3} in low and medium predicted radon potentials. These proportions rise up to 22 and 45% respectively for high and very high predicted radon potentials. This predictive map of indoor radon potential based on the radiogeochemical data was validated using a map of confirmed radon exposure in homes based on the basement radon measurements. It was shown that the map of predicted radon potential based on the radiogeochemical data was reliable to identify radon-prone areas even in zones where no indoor radon measurement exists. - Highlights: • 5 radiogeochemical datasets were used to map the geogenic indoor radon potential. • An indoor radon potential was determined for

  7. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, A. [Vienna Univ. of Technology, Atominstitut, Wien (Austria); Maringer, F.J.; Michai, P.; Kreuziger, M. [BEV-Federal Office of Metrology and Surveying, Wien (Austria)

    2006-07-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  8. What did we learn from the Austrian radon project?

    International Nuclear Information System (INIS)

    Friedmann, H.

    2004-01-01

    Approximately 40000 measurements of indoor radon concentrations were performed in randomly selected homes during the Austrian Radon Project. These measurements were carried out by using long-term measuring devices (SSNTD and Electret detectors) and short-term charcoal detectors with liquid scintillation counting as the method of analysis. In addition to the equilibrium factor, soil gas measurements and quasi-continuous indoor measurements, parallel-measurements with different detector systems in randomly selected homes were also performed. Very different results were occasionally obtained for one and the same room at the same time. This was so not only when comparing the long-term and short-term measuring devices; actually, different long-term detector systems also often showed significant discrepancies in results, although all detector systems had been carefully calibrated and tested in laboratories. The essential conclusion was that during a longer exposure in randomly selected homes, the detectors may be moved, opened, or handled in other unfavourable ways which introduce additional uncertainties in the measuring results. The aim of the Austrian Radon Project was to estimate the radon risk for geographic areas (municipalities). This task is different from the evaluation of the mean radon concentration in a single home. Generally, while long-term measurements (a year or even longer) are necessary to get reliable results for a particular house, this is not so where only the mean indoor radon concentrations for an area are of interest. Observed indoor radon concentrations give information about the actual radon exposures of the inhabitants but not about the radon risk from the ground. The house type, the way the house is constructed, the storey where people live, and some living patterns (ventilation rate etc.) modify the geological risk significantly, although it is the geological situation that has to be primarily taken into account when planning and constructing

  9. Determination of the radon Concentration in underground water in selected areas in and around Kumasi

    International Nuclear Information System (INIS)

    Owusu, Seth Adjei

    2012-06-01

    Radon (Rn-222) is a radioactive noble gas of natural origin that may be found anywhere in soil, air and different types of water: surface, borehole, well and spring. It is worth to carry out surveys for the radon in water for radiation protection as well as for geological considerations. The research presenters here was carried out in selected towns in and around Kumasi for the determination of radon concentration in groundwater. The major towns from which samples were taken are , Mowire, Kronum, Aburaso, Medoma, Kenyase, Buokrom, Bomfa, Ayeduase, Kotei, Tikrom. All the samples are used for domestic purposes such as cooking, drinking, bathing and washing. Waters from boreholes and wells in the selected towns were sampled and the radon concentration level measured. The Roll’s method was used for the radon concentration analysis on all the 100 samples. The results shows that, the minimum radon concentration in groundwater was 13015.934 Bq/m3 and it was found at Bomfa, and the highest was found to be 964628.480 Bq/m3, recorded at Mowire. It is believed that this variation of levels is mainly due to the difference in rock type, soil type and geology of the area as well as the depth of the water samples. This information can be used to estimate the possible health hazards from radon in the selected towns in the future from environmental point of view. The data would promote public awareness related to risk of radon exposure. (au)

  10. Investigation of Radon in drinking water from wells of the North-Eastern region of Bosnia and Herzegovina

    International Nuclear Information System (INIS)

    Adrovic, Feriz; Dedic, Amela

    2008-01-01

    Some areas of the Tuzla region (B and H) suffer heavily from the shortage of quality drinking water. The only real long-term water resource in this region is the Lake Modrac, the largest accumulation lake in Bosnia and Herzegovina. Due to the fact that radon is soluble in water it can be transported by water to long distances. In cases of intake of waters rich in radon the most affected are sensitive cells within the abdomen and other internal organs. In order to satisfy the needs for drinking water, people are forced to excavate and drill wells. In the area of Tuzla region and the entire B and H excavated wells are very frequent, and so are drilled wells lately, due to more developed and cheaper technology for soil drilling. Such activities in this area, and the whole of B and H, are carried out in an unorderly manner and without previously completed chemical and radiological analyses of soil and water samples. The University of Tuzla formed the Laboratory for detection of radon in all environments, and the survey displayed in this paper have been the first investigation of that kind in B and H. Here we presented the results of radon survey of drinking waters from excavated and drilled wells in the area of Tuzla region (North-Eastern region of B and H). The measurements were conducted over the period of one year (2006), so as to make possible monitoring of variations of radon concentrations in dependence of meteorological changes. These investigation works showed that radon concentration at most locations was significantly higher in drilled wells than in excavated wells. Mean values of radon concentration in the tested water samples ranged within the interval of 101-4200 Bq/m 3 . Radon activity concentration was measured with the Alpha GAURD radon system (Genitron instruments-Frankfurt). (author)

  11. Radon in soil and homes of Osijek

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.; Faj, Z.; Radolic, V.; Stanic, D.

    2002-01-01

    Radon, 2 22R n, is an inert radioactive gas which arises from decay of 2 26R a and ultimately from 2 38U . These parent elements are ubiquitous in the crust of the earth, although with very various concentrations. It has been recognized that Rn gas can accumulate in homes, sometimes to levels that can exceed occupational standards for mines. Enhanced concentrations of indoor radon and its also-emitting progeny 2 14P o and 2 18P o can increase the risk of pulmonary diseases, that was first observed still among underground miners (ICRP, 1987; Lubin et al., 1990; Gilliland et al., 2000). Because of the uncertainty inherent in extrapolating risks from studies of miners to the general population, epidemiological studies have been undertaken to confirm the presumed harm (carcinogenesis) of indoor radon ( Stidley and Samet, 1993; Cohen, 1995). We undertook so called ecologic and case-control studies for inhabitants of the Osijek town (East Croatia, a hundred thousand citizens) to investigate an association between indoor radon exposure and lung cancer rate; some results showed a positive linear regression for the mentioned variables, although the correlation coefficient was not statistically significant, or statistical samples were not large enough (Planinic et al., 2002; further investigation is going on). A particular problem was to determine indoor radon concentrations with a satisfied precision (that reduces sample size), as well as to find a cause of their variation

  12. Control of respirable particles and radon progeny with portable air cleaners

    International Nuclear Information System (INIS)

    Offermann, F.J.; Sextro, R.G.; Fisk, W.J.; Nazaroff, W.W.; Nero, A.V.; Revzan, K.L.; Yater, J.

    1984-02-01

    Eleven portable air cleaning devices have been evaluated for control of indoor concentrations of respirable particles and radon progeny. Following injection of cigarette smoke and radon in a room-size chamber, decay rates for particles and radon progeny concentrations were measured with and without air cleaner operation. Particle concentrations were obtained for total number concentration and for number concentration by particle size. In tests with no air cleaner the natural decay rate for cigarette smoke was observed to be 0.2 hr -1 . Air cleaning rates for particles were found to be negligible for several small panel-filters, a residential ion-generator, and a pair of mixing fans. The electrostatic precipitators and extended surface filters tested had significant particle removal rates, and a HEPA-type filter was the most efficient air cleaner. The evaluation of radon progeny control produced similar results; the air cleaners which were effective in removing particles were also effective in removing radon progeny. At low particle concentrations plateout of the unattached radon progeny is an important removal mechanism. Based on data from these tests, the plateout rate for unattached progeny was found to be 15 hr -1 . The unattached fraction and the overall removal rate due to deposition of attached and unattached nuclides have been estimated for each radon decay product as a function of particle concentration. While air cleaning can be effective in reducing total radon progeny, concentrations of unattached radon progeny can increase with increasing air cleaning. 39 references, 26 figures, 9 tables

  13. Review of selected state-of-the-art applications of diagnostic measurements for radon-mitigation planning. Report for April 1986-June 1987

    International Nuclear Information System (INIS)

    Hubbard, L.M.; Harrje, D.T.; Gadsby, K.J.; Sanchez, D.C.; Turk, B.H.

    1987-09-01

    Since late-1984, EPA's AEERL has supported a program to develop and demonstrate radon-mitigation techniques for single-family detached dwellings. As part of the program, projects have been started, directed at developing and demonstrating the use of diagnostic measurements in all phases of the radon-mitigation process. Diagnostic measurements are used to assess: (1) the radon sources strengths, variability, and locations; and, (2) radon transport to the house and its entry and distribution in the house as influenced by environmental, house characteristics, and occupancy factors. The diagnostic measurements reported include: (1) soil-gas grab sampling; (2) communication (air flow or pressure-field extension) tests; (3) whole house infiltration; (4) differential pressure, (5) gamma radiation; and, (6) radon flux. The paper concludes that the above selected diagnostic measurements were especially useful in characterizing houses with indoor radon problems attributable to soil-gas-borne radon that may be amenable to mitigation through the use of subslab ventilation

  14. Radon in geological medium

    Energy Technology Data Exchange (ETDEWEB)

    Hricko, J [GEOCOMPLEX, a.s., Bratislava (Slovakia)

    1996-12-31

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a{sub v} has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km{sup 2}. The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a{sub v} > 50 kBq/m{sup 3}). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs.

  15. Radon in geological medium

    International Nuclear Information System (INIS)

    Hricko, J.

    1995-01-01

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a v has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km 2 . The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a v > 50 kBq/m 3 ). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs

  16. Improved radon-flux-measurement system for uranium-tailings pile measurement

    International Nuclear Information System (INIS)

    Freeman, H.D.

    1981-10-01

    The Pacific Northwest Laboratory (PNL) is developing cover technology for uranium mill tailings that will inhibit the diffusion of radon to the atmosphere. As part of this cover program, an improved radon flux measurement system has been developed. The radon measurement system is a recirculating, pressure-balanced, flow-through system that uses activated carbon at ambient temperatures to collect the radon. With the system, an area of 0.93 m 2 is sampled for periods ranging from 1 to 12 h. The activated carbon is removed from the radon trap and the collected radon is determined by counting the 214 Bi daughter product. Development of the system included studies to determine the efficiency of activated carbon, relative calibration measurements and field measurements made during 1980 at the inactive tailings pile in Grand Junction, Colorado. Results of these studies are presented

  17. Comparison of five-minute radon-daughter measurements with long-term radon and radon-daughter concentrations

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1983-01-01

    Five-minute air filter radon daughter measurements were made in 84 buildings in Edgemont, South Dakota, in which annual average radon daughter concentrations have been determined from six 100-hour Radon Progeny Integrating Sampling Unit (RPISU) measurements. Averaging radon concentrations were also determined in 50 of these buildings using Terradex Track Etch detectors. The standard deviation of the difference between the (natural) logarithms of the RPISU annual averages and the logarithms of the air filter measurements (SD-ln) was found to be 0.52. This SD-ln is considerably smaller than the SD-ln of 0.71 between the RPISU annual averages and the air filter measurements reported by ALARA at Grand Junction, Colorado; presumably because a considerable number of air filter measurements in Edgemont were disregarded because of short turnover times or high wind speeds. Using the SD-ln of 0.52 it can be calculated that there would only be a 5% probability in Edgemont that the RPISU annual average would be greater than 0.015 WL if the five-minute measurement were equal to 0.010 WL. This indicates that the procedure used in Edgemont of clearing buildings from remedial action if the five-minute measurement were less than 0.010 WL was reasonable. There was about a 28% probability that the RPISU annual average would be less than 0.015 WL if the five-minute measurement were 0.033 WL, indicating that the procedure of performing an engineering assessment if the average of two five-minute measurements was greater than 0.033 WL was also reasonable. Comparison indicates that the average of two RPISU measurements taken six months apart would provide a dependable estimate of the annual average

  18. Radiation exposure due to radon and radon daughters

    International Nuclear Information System (INIS)

    Ullmann, W.

    1976-01-01

    Underground miners working over long periods of time in mines with a high content of radon and radon daughters belong to that group of occupationally exposed persons who are subject to the greatest somatic risk, with values especially high if the permissible dose limits are exceeded. Follwing an overview of the permissible limits currently in use for radon and radon daughters as well as the results of examinations performed in nationally-owned underground mining of the G.D.R., considerations are presented on the measuring quantities requisite for statistical, control and safety measurements in this field. Finally, conclusions are drawn concerning the measuring procedures and instruments to be employed for practical work. (author)

  19. Radon remedial measures in cold climate

    International Nuclear Information System (INIS)

    Birovljev, A.

    2004-01-01

    A view is taken that mitigation of an indoor radon problem is often more complex than usually assumed, and that additional factors should be considered to avoid situations in which after mitigation the radon problem may be solved, but other problems have been created. Emphasis is put on how the choice and design of radon remedial measures are influenced not only by effectiveness in reducing radon levels indoors, but also by climatic factors, energy-saving aspects, as well as economic and psycho-social factors. Climatic conditions give rise to several concerns when attempting to mitigate a radon problem in areas with large seasonal temperature variations. Problems with humidity, energy consumption and durability of sealing materials are probably the most prominent issues. Commonly used radon remedial measures and their effectiveness in Norway is reviewed. Discussion is focused on principles and technical solutions which produce good results, and those which don't perform so well in cold Norwegian climate. Innovative technical solutions which successfully resolve some of the main conflicting issues are discussed. Results of some preliminary tests showing performance of such solutions in reduction of radon levels are presented. Other aspects of mitigation systems, such as need and cost of maintenance, longevity, noise levels, 'additional benefits', etc., are briefly mentioned. Homeowners' perceptions and willingness to implement various mitigation solutions are briefly reviewed. Based on discussion, several guiding principles which may be adopted in search for optimal solutions are suggested. (author)

  20. BGS Radon Protective Measures GIS

    International Nuclear Information System (INIS)

    Appleton, D.; Adlam, K.

    2000-01-01

    The British Geological Survey Radon Protective Measures Geographical Information System is described. The following issues are highlighted: Identification of development sites where radon protection is required in new dwellings; Mapping radon potential on the basis of house radon and geology; Radon Protective Measures GIS; Radon site reports; and Follow-up radon protective measures sire reports

  1. Testing of indoor radon-reduction techniques in basement houses having adjoining wings. Final report, August 1988-September 1989

    International Nuclear Information System (INIS)

    Messing, M.

    1990-11-01

    The report gives results of tests of indoor radon reduction techniques in 12 existing Maryland houses, with the objective of determining when basement houses with adjoining wings require active soil depressurization (ASD) treatment of both wings, and when treatment of the basement alone is sufficient. In five basement houses with adjoining slabs on grade, ASD treatment of both wings provided an incremental additional radon reduction of 0 to 5.2 pCi/L, compared to ASD treatment of either one of the slabs alone. However, basement-only treatment reduced radon to <4 pCi/L in all five houses. In six basement houses having adjoining crawl spaces, ASD treatment of both wings (including sub-liner depressurization of the crawl space) provided little additional reduction compared to basement-only treatment, when sub-slab communication was good. When communication was not good, treatment of both wings was required to achieve <4 pCi/L. Tests of one fully slab-on-grade house showed that, when there is good aggregate under the slab, a one-pipe sub-slab depressurization system can achieve <1-2 pCi/L, even when there are forced-air supply ducts under the slab

  2. A feasibility study of geogenic indoor radon mapping from airborne radiometric survey in northern Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Wattananikorn, K. [Department of Physics, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand)], E-mail: kittic@science.cmu.ac.th; Emharuthai, S. [Department of Physics, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Wanaphongse, P. [Office of Atoms for Peace, Bangkok (Thailand)

    2008-01-15

    Experiments were carried out in seven test sites on three Quaternary alluvial and terrace deposit basins of northern Thailand, to test the possibility of using airborne equivalent uranium to predict geogenic indoor radon values of the region. The methodology was based on the correlation among soil gas permeability, soil radon concentration and indoor radon, as well as a relationship between soil radon and airborne uranium values. The methodology established works rather well when tested in areas of known indoor radon. Based on the predicted values that were obtained from this method, indoor radon in most areas of alluvial and terrace deposit basins of northern Thailand is less than 44Bq/m{sup 3}. There is no area in these basins where predicted indoor radon exceeds 74Bq/m{sup 3}.

  3. Radon, a real threat to our health

    International Nuclear Information System (INIS)

    Mauna, T.; Mauna, A.; Ghita, R.

    2005-01-01

    Radon is invisible, odorless and tasteless a radioactive gas that comes from the radioactive decay of naturally occurring uranium and thorium in soil and rock, can concentrate in domestic homes, overground workplaces, and caves. Radon has been identified as the second leading cause of lung cancers in the U.S., about 20.000 per year, and is present in millions of homes. The Environmental Protection Agency (EPA) of USA designated January 2005 as National Radon Action Month (NRAM) and held the second week of October every year as National Radon Action Week (NRAW). The focus of NRAM and NRW is to promote awareness about, testing for and mitigation of indoor radon gas with various events and outreach campaigns. The EPA considering radon exposure as capital problem for the population health decided to have a special dedicated free phone number the similar for every county state of USA taking into account the increase easy call by interested people. Many universities and research centers, including NGO from different countries world wide, following the recommendation of 'United Nations Scientific Committee on the Effects of Atomic Radiation' (USNCEAR) and 'International Commission on Radiological Protection ' (ICRP) until 1977, developed their own radon researches in order to clarify the properties, area distribution and concentration, geological production and other needed aspects. This paper compare the radon risk versus radioactive waste gaseous Nuclear Power Plant release in normal or abnormal operation and underlines the needs for Romanian's radiation research laboratories to undertake radon protection programs similar to to those underway in other countries. (authors)

  4. Development of in-situ radon sensor using plastic scintillator

    International Nuclear Information System (INIS)

    Shitashima, Kiminori

    2009-01-01

    Underwater in-situ radon measurement is important scientific priority for oceanography, especially for survey and monitoring of submarine groundwater discharge (SDG). The high sensitivity and lightweight underwater in-situ radon sensor using NaI(Tl) doped plastic scintillator was developed for application to SDG research. Because NaI(Tl) doped plastic scintillator contacts seawater directly, the plastic scintillator can expect high sensitivity in comparison with NaI(Tl) crystal sealed in a container. In order to improve condensation efficiency of scintillation, the plastic scintillator was processed in funnel form and coated by light-resistant paint. This sensor consists of plastic scintillator, photomultiplier tube, preamplifier unit, high-voltage power supply, data logger and lithium-ion battery, and all parts are stored in a pressure housing (200φx300L). The newly developed underwater in-situ radon sensor was tested at hydrothermal area (underwater hot springs) that the hydrothermal fluid containing high concentration of radon is discharged into seawater. The sensor was operated by a diver, and sensitivity tests and mapping survey for estimation of radon diffusion were carried out. The signals of the radon sensor ranged from 20 to 65 mV, and these signals corresponded with radon concentration of 2 to 12 becquerels per liter. The sensor was able to detect radon to 20 m above the hydrothermal point (seafloor). Since the sensor is small and light-weight, measurement, monitoring and mapping can perform automatically by installing the sensor to an AUV (autonomous underwater vehicle). Furthermore, underwater in-situ radon sensor is expected an application to earthquake prediction and volcanic activity monitoring as well as oceanography and hydrology. (author)

  5. Evaluation of radon related parameters in environmental samples from Jazan city, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    M. Abo-Elmagd

    2018-01-01

    The overall weighted mean of areal exhalation rate (EA and effective Radium content (Raeff for soil samples collected from different 10 districts in Jazan city is 17.02 ± 2.06 Bq m−2d−1, 3.01 ± 0.37 Bq kg−1 respectively. For 20 Building materials samples, EA = 1.989 ± 1.056 Bq m−2d−1 and Raeff = 0.351 ± 0.186 Bq kg−1. Finally, for decorative materials (23 samples, EA = 1.225 ± 0.136 Bq m−2d−1 and Raeff = 0.427 ± 0.031 Bq kg−1. The maximum values of the measured parameters are found in the soil of scheme 5 and 6 district, red sand (building material and gypsum (decorative material. As the mass of the sample increase, more and more radon diffused back into the sample and the measured effective radium content is reduced. After correcting the results for back diffusion effect, all masses approximately get the same value of effective radium content and then reduced the uncertainty in the weighted mean.

  6. Radon concentration measurements in waters in Greece and Cyprus

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Tzortzi, A.; Thanassas, D.; Serefoglou, A.; Georgiou, E.; Vogiannis, E.; Koukouliou, V.

    2004-01-01

    A total of 35 measurements in Greece and 15 in Cyprus were performed. Radon concentrations in drinking water in Greece were from (1.1±0.5) to (410±50) Bq/L. The corresponding concentrations in underground potable waters in Cyprus ranged between (0.4±0.3) Bq/L and (15±4) Bq/L. High concentrations, viz. (120±20), (320±40) and (410±50) Bq/L, were observed in three samples collected from the city of Arnea Chalkidekis in northern Greece. One water sample from Lesvos Island (north-eastern part of Greece) exhibited a radon concentration of (140±20) Bq/L. Six samples of hot spring water from the city of Loutraki (Attica prefecture), characterized as 'medicinal drinking water', contained concentrations of radon between (220±10) and (340±20) Bq/L. Radon concentrations in potable and non-potable underground water in Greece and Cyprus ranged between (0.4±0.3) and (15±4) Bq/L, whereas in surface water the range was from (2.7±0.8) to (24±6) Bq/L. (P.A.)

  7. Indoor radon concentrations in kindergartens from different regions of Yugoslavia

    International Nuclear Information System (INIS)

    Vaupotic, J.; Krizman, M.; Sutej, T.

    1992-01-01

    In the winter period of 1990-1991 instantaneous radon concentrations in air were measured in around 450 kindergartens from different regions from Yugoslavia. Alpha scintillation counting was used as a screening method, and the measurements were carried out in rooms where the children spent the majority of their time. All of the air grab samples were taken under the same conditions which excluded ventilation of the interior 12 h prior to sampling. In addition to indoor radon concentrations, gamma dose rate was measured using portable equipment. The indoor radon concentrations were generally low, in the range from 10 to 180 Bq.m -3 of air, with an overall average of about 100 Bq.m -3 . There were a few exceptions where indoor radon levels exceeded 150 Bq.m -3 ; mainly in old buildings containing higher contents of natural radionuclides in the building materials, and in the cellars or basements of the buildings. In all rooms with a level exceeding 150 Bq of 222 Rn per m 3 , solid-state nuclear track detectors were applied for long-term measurements. In order to investigate the equilibrium between radon and its short-lived daughters, mainly with respect to their contribution to the effective dose, alpha spectrometry is also being introduced in selected kindergartens with elevated radon concentrations. (author)

  8. Study of radon transport through concrete modified with silica fume

    International Nuclear Information System (INIS)

    Chauhan, R.P.; Kumar, Amit

    2013-01-01

    The concentration of radon in soil usually varies between a few kBq/m 3 and tens or hundreds of kBq/m 3 depending upon the geographical region. This causes the transport of radon from the soil to indoor environments by diffusion and advection through the pore space of concrete. To reduce indoor radon levels, the use of concrete with low porosity and a low radon diffusion coefficient is recommended. A method of reducing the radon diffusion coefficient through concrete and hence the indoor radon concentration by using silica fume to replace an optimum level of cement was studied. The diffusion coefficient of the concrete was reduced from (1.63 ± 0.3) × 10 −7 to (0.65 ± 0.01) × 10 −8 m 2 /s using 30% substitution of cement with silica fume. The compressive strength of the concrete increased as the silica-fume content increased, while radon exhalation rate and porosity of the concrete decreased. This study suggests a cost-effective method of reducing indoor radon levels. -- Highlights: • Radon diffusion study through silica fume modified concrete was carried out. • Radon diffusion coefficient of concrete decreased with increase of silica fume contents. • Compressive strength increased with increase of silica fume. • Radon exhalation rates and porosity of samples decreased with addition of silica fume. • Radon diffusion coefficient decreased to 2.6% by 30% silica fume substitution

  9. Novel technique of reducing radon levels in living premises

    International Nuclear Information System (INIS)

    Khaydarov, R.A.; Gapurova, O.U.; Khaydarov, R.R.

    2006-01-01

    Full text: Radon is a naturally occurring gas seeping into homes and underground structures (buildings, tunnels, hangars, garages, etc.) from the surrounding soil through walls, floor, etc. and emanating from construction materials such as concrete, granite, etc. The level of radon is especially great in regions with the higher content of uranium in soil and water and with geological breaks of the Earth's crust. Concentrations of uranium higher than 10 g per ton of soil have been found in 14% of territory of Uzbekistan. As a result, for instance, concentration of radon 10-100 times exceeds the regulation level in 14% of premises in Tashkent, 41% of premises in Almalik town and 44% in Yangiabad town. The purpose of this work was creating a method to reduce concentration of radon gas in buildings and underground structures. We suppose that the most effective technique is a treatment of walls, floors, etc. of basement and underground structures by special chemicals which seal micropores inside the construction materials. Sealing the pores stops radon diffusion and, in addition, it blocks another radon pathway - water migration and emanation from concrete, gypsum or other construction materials. In the paper polymeric silicoorganic compounds are investigated and selected as the chemicals to prevent radon seeping indoors. Gas (air, Ar, Rn-222, H 2 O) permeability of concrete and gypsum after treatment by chemicals has been examined. Influence of types of cement and sand, preliminary treatment by different chemicals, different types of polymeric silicoorganic compounds, time between treatments, moisture of concrete, time between preparation of chemicals and treatment of concrete (ageing of chemicals), time between treatment of concrete and testing (ageing of treated concrete) have been examined. Surfaces of the samples were treated by spray. Experiments have shown that chosen method of treatment of the construction materials allows reducing the coefficient of gas

  10. Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia

    Energy Technology Data Exchange (ETDEWEB)

    Bartolo, D. de; Alberici, A.; Gallini, R.; Maggioni, T.; Mondini, A.; Zini, E. [A.R.P.A. della Lombardia, Milano (Italy); Arrigoni, S.; Cazzaniga, P.; Cugini, A.; Gallinari, G.; Olivieri, F.; Romanelli, M. [A.R.P.A. della Lombardia, Dipt. di Bergamo, Bergamo (Italy)

    2006-07-01

    Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification of the sites. The measurements were carried out using C.R. 39 trace detector technique. The detectors were contained in closed plastic canisters and they were positioned in situ for one year and measured each semester. The detectors were chemically treated and the traces counted using the automated optical system installed at the Radiometric Laboratory of the A.R.P.A. Department in Bergamo. The instrument accuracy and precision were evaluated using data obtained with different methods: using detectors exposed to radon known concentrations, participating to an international intercomparison as well as exposing the detector in a national calibration centre. Due to the large amount of detectors involved, a particular attention was taken for the detector homogeneity response and for the optimization of the analysis parameters. For further investigating the reliability of the measurements, two detectors were used in parallel in 10% of the tests. The results show higher values in the areas of Bergamo, Brescia

  11. Determination of radon exhalation rates from tiles using active and passive techniques

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I. E-mail: mibrahim@kfupm.edu.sa; Abu-Jarad, F.; Fazal-ur-Rehman

    2001-06-01

    Measurements of radon exhalation rates for selected samples of tiles used in Saudi Arabia were carried out using active and passive measuring techniques. These samples were granite, marble and ceramic. In the active method, a PC-based radon gas analyzer with emanation container was used, while, in the passive method, PM-355 nuclear track detectors with the 'can technique' were applied for 180 days. A comparison of the exhalation rates measured by the two techniques showed a good linear correlation coefficient of 0.7. The granite samples showed an average radon exhalation rate of 0.7 Bq m{sup -2} h{sup -1}, which was higher than that of marble and ceramic by more than twofold. The radon exhalation rates measured by the 'can technique' showed a non-uniform exhalation from the surface of the same tile.

  12. Radon Measurements in Vojvodina

    International Nuclear Information System (INIS)

    Bikit, I.; Bikit, K.; Forkapic, S.; Mrda, D.; Nikolov, J.; Todorovic, N.; Veskovic, M.

    2013-01-01

    Recent analyses of epidemiological studies of lung cancer risk from residential exposures demonstrate a statistically significant increase per unit of exposure below average annual concentrations of about 200 Bq/m 3 . Indoor radon measurements performed in Novi Sad in about 400 houses and flats are presented and discussed in this paper. By measuring gamma-activity of radon daughters, radon activity concentration was determined to be 50 Bq/m 3 . In Vojvodina region indoor radon levels were measured by alpha track detectors CR-39 on about 3000 locations during the winter seasons in the period of three years (2003-2005). The main aim of the present study was to explore the critical group of population for radon exposure and to estimate maximal annual doses. Existing radon maps which identify regions with elevated radon levels will improve data collection and analysis for the future radon campaigns. Collaboration on the JRC program of European indoor radon map and implementation of grid system are also discussed.(author)

  13. Radon and cancer

    International Nuclear Information System (INIS)

    2011-01-01

    This publication proposes an overview on what is known about the carcinogenic effect of radon. It recalls the origin of radon, its presence in the environment, and its radioactivity. It comments data on the relationship between exposure to radon and lung cancer, and with other forms of cancer. It discusses the role of the exposure level, and the cases of professional and domestic exposure with respect to these risks. It indicates the hazardous areas in France which are well identified, outlines that smokers are more likely victims of risks related to radon, that this risk is still underrated and underestimated (notably by the public). It gives an overview of existing regulations regarding exposure to radon, of public health policies and national plans concerning radon, and recalls some WHO recommendations

  14. Lithological and seasonal variations in radon concentrations in Cypriot groundwaters

    International Nuclear Information System (INIS)

    Tasoula Kiliari; Anastasia Tsiaili; Ioannis Pashalidis

    2010-01-01

    The paper presents and discusses radon activity concentrations in Cypriot groundwater systems as a function of the background lithology and seasonal/meteorological conditions using an airborne radon monitoring system (ARM) after separation of radon by out-gassing. Radiometric analysis of groundwater samples obtained from non-contaminated systems showed that radon concentration in groundwaters varies strongly (0.1-10 Bq L -1 ) depending mainly on the hosting geological matrix but also to lesser degree on atmospheric/meteorological conditions. The associated excess annual dose has been estimated to range between 10 -6 and 10 -4 mSv y -1 , which is an insignificant contribution to the radiation exposure of the Cypriot population caused by airborne radon (0.5 ± 0.4 mSv y -1 ). (author)

  15. Radon awareness in Ireland: a assessment of the effectiveness of radon road shows

    International Nuclear Information System (INIS)

    Synnott, H.

    2006-01-01

    Full text: In late 2004 the Radiological Protection Institute of Ireland (R.P.I.I.) initiated a series of radon road shows in areas designated as High Radon Areas 1 in the R.P.I.I. s national radon survey of homes. The main objective of these road shows was to provide information to a local audience on the risks of exposure to radon. These road shows target both employers and householders. Each road show has the same general format. A presentation and/or meeting with a major employer representative group within the area. The purpose is to make employers aware of the risks associated with exposure to radon in the workplace and to highlight their obligations under current Irish health and safety legislation regarding radon in the workplace. An information stand on radon manned by R.P.I.I. staff members in a local shopping centre or other similar area. This provides those concerned about radon with accessible information on radon exposure risks, how to measure radon and the steps a home owner could take to reduce radon concentrations where necessary. Where possible R.P.I.I. staff members visit one or more schools in the general area. A short presentation on radon was given to students and students were given an opportunity to asks questions Maximizing media exposure to publicize our visits is vital to the success of these visits. Each visit is preceded by a Press Release whose main aim is to brief local and national media on the radon issue so as to achieve maximum publicity mainly through radio and television coverage. In general the media are very interested in the whole radon area and R.P.I.I. staff members have given 57 radio and 10 television interviews to date since the commencement of this initiative. The four road shows carried out to date have been successful in encouraging householders to carry out radon measurements. Since the start of the road shows to the present, the R.P.I.I. has seen a 44% increase in the number of householders requesting radon

  16. Emanation of radon-222 in uraniferous phosphorite from Pernambuco, Brazil; Emanação de radônio-222 em fosforito uranífero de Pernambuco

    Energy Technology Data Exchange (ETDEWEB)

    Santos, M.L.O.; França, E.J.; Amaral, D.S.; Silva, K.E.M.; Hazin, C.A.; Farias, E.E.G., E-mail: emersonemiliano@yahoo.com.br [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2017-07-01

    The concentration of radon-222 activity available for transport to the surface through the pore space can be defined as radon emanation. From the decay of radium-226, whose half-life is 1850 years, it is associated with the development of neoplasia, such as lung cancer. In the Metropolitan Region of Recife, sedimentary rocks known as phosphorites have been known since 1959, so, from the radiometric characterization of the Paulista and Igarassu Municipality, in Pernambuco, emanation tests were carried out, aiming to determine the emanation power of radon in samples of uraniferous phosphorite from the Recife Metropolitan Region. Initially, 6 independent samples of phosphorites with activity concentration of {sup 226}Ra> 400 Bq kg{sup -1} were comminuted. Portions of 5g were conditioned in a radon chamber with 500 mL volume for measurements. The linear fit of the model converged after 200 interactions with selection of the best fit by the Chi-Square test, through the Origin® 8.0 program. After analysis of the samples, radon emanation power was estimated in the range of 7% to 15%, with a mean value of 10.8%. The methodology used to determine the emanation parameters in samples of uraniferous phosphorite was adequate, observing an inversely proportional relation between the concentration of the radium-226 and the emanation power.

  17. Project Radon

    International Nuclear Information System (INIS)

    Ekholm, S.

    1988-01-01

    The project started in March 1987. The objective is to perform radon monitoring in 2000 dwellings occupied by people employed by State Power Board and to continue to contribute to the development of radon filters. The project participates in developing methods for radon measurement and decontamination and in adapting the methods to large scale application. About 400 so called radon trace measurements (coarse measurement) and about 10 action measurements (decontamination measurement) have been made so far. Experience shows that methods are fully applicable and that the decontamination measures recommended give perfectly satisfactory results. It is also established that most of the houses with high radon levels have poor ventilation Many of them suffer from moisture and mould problems. The work planned for 1988 and 1989 will in addition to measurements be directed towards improvement of the measuring methods. An activity catalogue will be prepared in cooperation with ventilation enterprises. (O.S.)

  18. Radon and radon daughters' concentration in spring and wells waters from Presidente Prudente: preliminary results; Concentracao de Rn-222 e filhos em aguas provenientes de pocos e emergencias de agua da regiao de Presidente Prudente: resultados preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Osorio, Ana Maria Araya; Saenz, Carlos Alberto Tello [Universidade Estadual Paulista Julio de Mesquita Filho (FCT/UNESP), Presidente Prudente, SP (Brazil). Departamento de Fisica Quimica e Biologia; Aguiar, Claudinei Rodrigues de [Universidade Tecnologica Federal do Parana (UTFPR), PR (Brazil); Pereira, Luiz Augusto Stuani [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Presidente Prudente, SP (Brazil)

    2009-07-15

    This work presents the preliminary results about the concentration of radon and radon daughters in wells and springs water from Presidente Prudente. Six water samples were studied: three from well-water, two from springs water and one from potable water. For the determination of α-activity the samples were placed inside plastic containers where the CR-39 tracks detectors were outside the water. The track density of α-particles were measured by using optical microscopy. The results show that one sample from well-water presented higher concentration of radon and radon daughters than the other samples. (author)

  19. Biological radiation effects of Radon in Drosophila

    International Nuclear Information System (INIS)

    Pimentel P, A.E.

    1995-01-01

    In order to contribute to the knowledge on the effects of radon and its decay products, the aim of this investigation is to study the biological effects of radon using Drosophila melanogaster throught the somatic mutation and recombination test (SMART) and the analysis of some adaptative factors exposing larvaes to controlled radon atmosphers, considering that this insect could be used as biological monitor. Using the somatic mutation test a mutagenic effect was observed proportional to radon concentration, into an interval of 1 ± 0.3 to 111 ± 7.4 KBq/m 3 equivalent to doses under 0.0106 Gy. The correlation analysis gives a linear (r=0.80) relationship with a positive slope of 0.2217. The same happens when gamma rays are used in the interval of 1 to 20 Gy, given a linear dose-dependent effect (r=0.878) is obtained; nevetheless the slop is smaller (m=0.003) than for radon. Analysing the results of adaptative factors of the nine exposed generations, it was found that probably radon exposition induced dominant lethals during gametogenesis or/and a selection of the more component gamets of the treated individuals in larval state. It was reflected in the significant decrease on fecundity of the generation exposed. Nevertheless the laying eggs had an increase in egg-to-adult viability and the develop velocity was higher than in control for 3 KBq/m 3 , this suggest that radon concentrations used were able to induce repair mechanisms. These data agree with the Hormesis hypothesis that says: low doses have positive effects on health. It was not possible to obtain a dose-effect relationship except with the develop velocity where it was found a dose-effect inverse proportion. In conclusion, Drosophila melanogaster could be a good system to obtain in vivo damaged induction concentration dependent of radon and its decay products, as well as to study the effects in an exposed population by the analysis of adaptative factors. (Author)

  20. Measurement of radon and thoron progenies in Coimbatore

    International Nuclear Information System (INIS)

    Sivakumar, R.; Selvasekarapandian, S.; Mahendraprasad, M.; Meenakshisundaram, V.; Santhanam, R.; Raghunath, V.M.

    2001-01-01

    The radon and thoron daughter concentrations have been measured in different dwellings of Coimbatore city by grab sampling method and two count. It has been found that the radon daughter concentration varies from 0.5 to 10.5 mWL with mean value of 2.9 mWL and that of thoron progeny is from 0.7 to 16.3 mWL with mean value of 3.8 mWL. The average annual effective dose equivalent due to radon daughters is found to be 1.3 mSv and that of thoron progeny is 3.8 mSv. (author)

  1. Radon in private water supplies: the unknown risk

    International Nuclear Information System (INIS)

    Clapham, D.; Horan, N.J.

    1996-01-01

    Radon gas, which is the main contributor to human radiation exposure, is easily dissolved in, and dissipated from, water. Problems with radon occur because, in addition to being ingested, it (a) becomes attached to particles which lodge in the lungs and (b) emits alpha radiation. Concentration has been found to increase inversely with the size of a water supply. Although of little problem in mains water, private water supplies in the UK have been found to contain more than ten times the recommended US levels. Despite this, very little monitoring is carried out for radon in private supplies. Local authorities, situated in areas where the geological conditions are such that high levels of radon would be expected, should carry out a suitable sampling and monitoring programme of their private water supplies. (Author)

  2. Measurement of the concentration of radon in the air

    International Nuclear Information System (INIS)

    Aten, J.B.Th.; Bierhuizen, H.W.J.; Hoek, L.P. van; Ros, D.; Weber, J.

    1975-01-01

    A simple transportable air monitoring apparatus was developed for controlling the radon contamination of air in laboratory rooms. It is not highly accurate but is sufficient to register the order of magnitude of the radon concentration. Air is pumped through a filter for one or two hours and an alpha decay curve of the dust on the filter is determined. Scintillation counting forty minutes after sampling indicates the radon activity. The calibration method of measuring the equilibrium of daughter product concentrations is discussed extensively

  3. Radiation dose due to radon and heavy metal analysis in drinking water samples of Jammu district, J. and K., India

    International Nuclear Information System (INIS)

    Ajay Kumar; Kaur, Manpreet; Sharma, Sumit; Mehra, Rohit; Sharma, Dinesh Kumar

    2015-01-01

    The aim of this study is to determine the relationship between the contaminant drinking water and its impact on human health. The most contaminants of ground water are heavy metals like arsenic, cadmium, mercury, copper, zinc and etc. These heavy metals particularly cause strong toxicity even at low concentration. Heavy metals are considered to be the major pollutants of water sources. Heavy metal toxicity can result in damaged or reduced mental and central nervous function, lower energy levels and damage to blood composition, lungs, kidneys, liver and other vital organs. Physicochemical parameters such as pH, electrical conductivity, total dissolved solids, salinity and dissolved oxygen were analyzed. For revealing the ground water quality and soil quality in area of Jammu, a total of 40 samples have been collected and analyzed for different kind of heavy metal concentration. These heavy metal concentrations in water samples were analyzed by Atomic Absorption Spectrophotometer (AAS). The results were compared with WHO, ED, ICMR and Indian. The trace metal analysis is not on the exceeding side of the permissible limit in all the samples. Along with the heavy metal concentration in water samples and soil samples, the radon concentration also measured by using RAD7. The values of radon concentration in drinking water samples were also compared within the safe limit recommended by different health agencies. (author)

  4. Radon reduction in waterworks

    International Nuclear Information System (INIS)

    Raff, O.; Haberer, K.; Wilken, R.D.; Funk, H.; Stueber, J.; Wanitschek, J.; Akkermann-Kubillus, A.; Stauder, S.

    2000-01-01

    The removal of radon from water using water aeration is one of the most effective methods for reducing radon in waterworks. Therefore, this report describes investigations on packed tower columns and shallow aeration devices and a method for mathematical modelling of gas exchange processes for dimensioning packed tower columns for radon removal. Moreover, possibilities for removing radon using active carbon filtration under waterworks typical conditions and for reducing indoor radon levels in waterworks are discussed. Finally, conclusions on the necessity of radon removal in German waterworks are drawn. (orig.) [de

  5. Radon gas sampler for indoor and soil measurements and its applications

    International Nuclear Information System (INIS)

    Azimi-Garakani, D.; Flores, B.; Piermattei, S.; Susanna, A.F.; Seidel, J.L.; Tommasino, L.; Torri, G.

    1988-01-01

    A national large scale survey of indoor radon (based on an optimised sampling strategy) is needed in Italy to obtain average population dose for use in epidemiological studies. Since in the great majority of cases, one of the most important radon sources is the soil and rock beneath the houses, it would be interesting to combine this survey with measurements of bed-soil radon. With these objectives in mind, a new radon monitor device has been developed consisting of two etched track detectors enclosed in a heat-sealed polyethylene bag. When compared with existing techniques, this radon gas sampler presents several advantages for both indoor and outdoor measurements. As a pilot project, radon gas measurements have been carried out in hundreds of different sites and for several locations; measurements have been made for different years. Typical houses with relatively high radon concentrations have also been thoroughly investigated. (author)

  6. Multidimensional simulation of radon diffusion through earthen covers

    International Nuclear Information System (INIS)

    Mayer, D.W.; Gee, G.W.

    1983-01-01

    The purpose of this report is to document applications of the RADMD model used at PNL to perform analyses of radon diffusion through uranium mill tailings cover systems. The accuracy of the numerical formulation of the RADMD model was demonstrated through a comparison with a two-dimensional analytic solution to the radon diffusion equation. Excellent agreement was obtained between two-dimensional radon concentration profiles predicted by RADMD and those obtained with the analytic solution. A simulation was made of radon diffusion into a test canister using the two dimensional capabilities of RADMD. The radon flux profile was computed and illustrates the effects of the canister on the surface radon flux. The influence of the canister on the radon flux was shown to be significant under certain circumstances. Defects in earthen cover systems were evaluated using the three dimensional capabilities of RADMD. The results support the expectation that defective covers can increase the surface flux from a covered talings pile. Compared to a cover with no defects, radon flux could be elevated by as much as a factor of three when 20% of the radon control layer area contained pockets of reduced moisture. The effects of temporal and spatial variations in moisture content have been modeled by coupling RADMD with a variable saturated flow model. Two dimensional simulations were made of the time dependence of radon flux from a tailings site before and after cover placement. The results demonstrated the expected flux reduction produced by a thick earthen cover. Time dependence of the radon flux after cover placement was attributed to slight changes in moisture content of the cover material with time. The particular cover studied had a compacted clay layer that effectively attenuated the radon

  7. Radon house doctor

    International Nuclear Information System (INIS)

    Nitschke, I.A.; Brennan, T.; Wadach, J.B.; O'Neil, R.

    1986-01-01

    The term house doctor may be generalized to include persons skilled in the use of instruments and procedures necessary to identify, diagnose, and correct indoor air quality problems as well as energy, infiltration, and structural problems in houses. A radon house doctor would then be a specialist in radon house problems. Valuable experience in the skills necessary to be developed by radon house doctors has recently been gained in an extensive radon monitoring and mitigation program in upstate New York sponsored by Niagara Mohawk Power Corporation and the New York State Energy Research and Development Authority. These skills, to be described in detail in this paper, include: (i) the use of appropriate instruments, (ii) the evaluation of the symptoms of a radon-sick house, (iii) the diagnostic procedures required to characterize radon sources in houses, (iv) the prescription procedures needed to specify treatment of the problem, (v) the supervision of the implementation of the treatment program, (vi) the check-up procedures required to insure the house cured of radon problems. 31 references, 3 tables

  8. Publications about Radon

    Science.gov (United States)

    There is no known safe level of exposure to radon. EPA strongly recommends that you fix your home if your test shows 4 picocuries (pCi/L) or more. These publications and resources will provide you with the information you need to fix your home.

  9. Operational air sampling report, January--June 30, 1992

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1992-09-01

    Nevada Test Site postshot and tunnel events generate beta/gamma fission products. The Reynolds Electrical ampersand Engineering Co., Inc. air sampling program is designed for measurement of these radionuclides at various facilities supporting these events. Monthly radon sampling is done for documentation of working levels in the tunnel complexes, which would be expected to hove the highest radon levels for on-site facilities. Out of a total of 281 air samples taken in the tunnel complexes, 25 showed airborne fission products with concentrations well below their respective Derived Air Concentrations (DAC). All of these were related to event reentry or mineback operations. Tritiated water vapor and radon levels were very similar to previously reported levels. The 975 air samples taken at the Area-6 decontamination bays and laundry were again well below any DAC calculation standard and negative for any airborne fission products from laboratory analyses

  10. Reasons for increasing radon concentrations in radon remediated houses

    International Nuclear Information System (INIS)

    Clavensjoe, B.

    1997-01-01

    The study comprises 31 single-dwelling houses where remedial actions were carried out in the 1980s. In all of them the radon concentrations have increased more than 30% according to recent control measurements. Radon sources are building material as well as the soil. The remedial actions dealt with ventilation systems, leakage through the basement floor, air cushions, sub-slab suction or radon wells according to the original problems. Causes for the increase varied: In many houses with soil radon problems, the installation of a normal mechanical ventilation system is not a good remedial action. In some houses on a ground with high permeability and high radon content in the soil air, the radon concentration may increase by the lowering of the indoor air pressure. In other houses the increase was a measurement effect, where sites/rooms were confused. Living related causes were identified in a number of cases, where fan speeds were reduced for energy conservation/noise reduction purposes or different use of windows airing had occurred. Extension of the dwelling space without changing the ventilation system caused the increase in one house. 23 refs

  11. The Italian national survey on radon indoors run by several different regional laboratories: Sampling strategy, realization and follow-up

    International Nuclear Information System (INIS)

    Bochicchio, F.; Risica, S.; Piermattei, S.

    1993-01-01

    The paper outlines the criteria and organization adopted by the Italian National Institutions in carrying out a representative national survey to evaluate the distribution of radon concentration and the exposure of the Italian population to natural radiation indoors. The main items of the survey - i.e. sampling design, choice of the sample size (5000 dwellings), organization, analysis of the actual sample structure, questionnaire to collect data about families and their dwellings, experimental set up and communication with the public - are discussed. Some results, concerning a first fraction of the total sample, are also presented. (author). 13 refs, 2 figs, 2 tabs

  12. Psychosocial aspects of Czech Radon Programme

    International Nuclear Information System (INIS)

    Fojtikova, I.; Neznal, M.; Hrdy, L.

    2004-01-01

    In November 1999 a radon awareness survey was conducted among Czech republic residents to evaluate their general awareness and the factual knowledge about radon, radon measurements and radon mitigation. This survey, however, did not provide any detailed information on whether the respondents' knowledge is deep and structured or it is just a chaotic mixture of impressions. Therefore, a new survey was conducted from May to November 2001. About 20 respondents, in whose houses the long term testing for radon levels had just been finished, were interviewed. The in-depth interviews had several main aims: a) to obtain a more detailed understanding of their general awareness and factual knowledge about radon; b) to learn more about the sources of their knowledge and of their perception of the radon risk; c) to get information as to whether householders accept radon remediation, and to identify any personal, attitudinal or other variables that can influence the householder's decision; and d) to experience the direct risk communication and conceive its effectiveness. The interviews confirmed some results of the former quantitative study, e.g. increasing knowledge correlating with increasing education level. They showed that the public, overloaded with information, is not disposed to search actively for other information sources (e.g. on the Internet). People perceive their knowledge as adequate and sufficient. Their approach to gathering information is very passive. Therefore, to enhance public understanding of radiation phenomena it is necessary to make efforts, including the use of public media, otherwise radioactivity will remain shrouded in myths. These myths often lead to underestimation of the radon risk. A typical example of such underestimation is a contention that there exist long-aged healthy people who live in extreme radon concentrations. Together with the interviews, a questionnaire describing 11 presumably risky situations or practices was used. Among other

  13. Measure of exposure of short-lived radon products using an alpha spectrometer for measuring indoor aerosol activity concentration and dose evaluation

    International Nuclear Information System (INIS)

    Berico, M.; Castellani, C. M.; Formignani, M.; Mariotti, F.

    2001-01-01

    A new italian law introduces the regulation of occupational exposure to radon. To evaluate the inhalation of radon daughters by the workers a sampling device has been assembled with the aim of evaluation of unattached and aerosol attached radon daughters' fractions. The instrument, based on selection of the aerosuspended particles by means of a wire screen type battery and subsequent collection on a total filter, allows to describe the behaviour of both fractions using defined temporal pattern of collecting particles and counting them by alpha spectroscopy. A measurement campaign to test the radon daughter dichotomous spectrometer in comparison with a commercial Radon Working Level meter, has been performed in a research laboratory of central Italy affected by high radon concentrations. The radon concentration during the measurement campaign has been also measured. The equilibrium factor F e q ad the attachment factor fp have been evaluated during 3 days campaign. Using the measured mean parameters (radon concentration, F e q, f p ) the dose evaluation for workers using dosimetric approach has been performed. A comparison between the epidemiologic approach, based on the radon concentration, and dosimetric approach is also presented [it

  14. Relation between residential radon concentrations and housing characteristics. The Cracow study

    International Nuclear Information System (INIS)

    Jedrychowski, W.; Flak, E.; Wesolowski, J.; Liu Kaishen

    1995-01-01

    The survey on indoor radon exposure was undertaken to explain whether the excess in lung cancer deaths in the Cracow city center may be attributed to this particular exposure. A total of 310 detectors was placed in households randomly chosen from three homogeneous strata of residential buildings. The first stratum included houses in the old city center constructed predominantly from stone bricks. The second stratum covered the city area with big apartment condominiums built from concrete blocks. The third stratum consisted of single family houses located in a suburban area. From each of these residency strata a random sample of an equal number of households was chosen, and the radon detectors were placed in households located at various levels of the buildings. The three-month radon sampling data were used to determine the distribution of various levels of radon in the households. In the measurement of radon exposure, Landauer α-track samplers were used. The data collected show that the type of building was the best single predictor of indoor radon concentrations. Other variables found to be associated significantly with indoor concentrations were the household level in the building and the house age. In general, residences with concrete slabs and dwellings with rarely-opened windows were found to have slightly higher radon concentrations. (author) 2 tabs., 15 refs

  15. The role of house surveys in geological radon potential mapping

    International Nuclear Information System (INIS)

    Ball, K.

    1997-01-01

    Because radon levels vary widely between apparently identical buildings on the same geological unit, no map can predict the radon level in an individual building. Maps can, however, give the probability that a building in a particular locality is above a threshold of radon concentration such as a reference or action level. The probability may be calculated for a particular building type or for a mixture of building types. In the latter case the probability is in effect an estimate of the proportion of buildings above the threshold level. Alternatively maps can provide estimates of the mean radon levels in buildings by area. Maps showing the geographical variation in probability that new or existing building will exceed a radon reference level are used to prevent excessive exposures to radon. The information may be used in various ways, such as to target information campaigns encouraging measurement of radon levels in homes or to modify regulations for new buildings. The data which are used to provide the estimates of the proportion of buildings above a threshold may be radon measurements results from a sample of buildings, or may be indirect indicators such as ground radium concentrations, emanation coefficients and permeability measurements. Consistency in radon measurement protocols and detailed positional information are prerequisites for mapping radon prone areas based upon house data. Grouping building radon measurements by geological formation and superficial cover can produce radon potential maps which are more spatially accurate than grid square maps and more accurate in estimating numbers of homes affected than mapping based only on measuring geological and pedagogical properties

  16. Indoor radon measurements and radon prognosis for the province of Kymi, southeastern Finland

    International Nuclear Information System (INIS)

    Pennanen, M.; Maekelaeinen, I.; Voutilainen, A.

    1996-12-01

    The purpose of the regional radon prognosis is to classify areas with different levels of radon risk. The radon prognosis gives the percentages of future homes expected to have indoor radon concentrations exceeding the levels of 200 and 400 Bq/m 3 . It is assumed that no protection against the entry of radon is used in construction. In this study about 5900 indoor radon measurements made in single family houses, semi-detached houses and row houses were used. Data on the location, geology and construction of buildings were determined from maps and questionnaires. An empirical statistical model, the adjusted indoor radon measurements and geological data were used to assess the radon risk from soil and bedrock in different areas. The building sites of the province of Kymi were divided into thirteen sub-areas. The radon prognosis are calculated for the most radon-prone foundation types including 1) houses with a slab-on-grade and 2) houses with a basement or hillside houses with open stairwells between basement and first floor. The radon levels are generally greater in the western part of the area. The radon risk is highest in gravel-dominated esker areas in southwestern, western (in Pyhtaa, Kotka, Anjalankoski, litti, Valkeala) and central (Taipalsaari) parts of the area. The radon risk is also high in some bedrock and till areas, also in southwestern and western parts of the area. In these areas the level of 200 Bq/m 3 will be exceeded in 80 % of new houses. About half of the future houses in these areas will have indoor radon concentrations exceeding 400 Bq/m 3 . The radon risk is lowest in the eastern part of the province of Kymi in every soil type. In this area the level of 200 Bq/m 3 will be exceeded in 30 % of new houses. Below 10 % will exceed 400 Bq/m 3 . (orig.) (14 refs.)

  17. Radon Concentration in Groundwater in the Central Region of Gyeongju, Korea - 13130

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Min; Lee, A. Rim; Park, Chan Hee; Moon, Joo Hyun [Dongguk University, Seokjangdong, Gyeongju, Gyeongbuk, 780-714 (Korea, Republic of)

    2013-07-01

    Radon is a naturally occurring radioactive gas that is a well known cause of lung cancer through inhalation. Nevertheless, stomach cancer can also occur if radon-containing water is ingested. This study measured the radon concentration in groundwater for drinking or other domestic uses in the central region of Gyeongju, Korea. The groundwater samples were taken from 11 points chosen from the 11 administrative districts in the central region of Gyeongju by selecting a point per district considering the demographic distribution including the number of tourists who visit the ancient ruins and archaeological sites. The mean radon concentrations in the groundwater samples ranged from 14.38 to 9050.73 Bq.m{sup -3}, which were below the recommendations by the U.S. EPA and WHO. (authors)

  18. Radon in workplaces

    International Nuclear Information System (INIS)

    Reichelt, A.; Lehmann, K.-H.; Reineking, A.; Porstendoerfer, J.; Schwedt, J.; Streil, T.

    2000-01-01

    The radiological assessment of the results of radon measurements in dwellings is not automatically applicable to workplaces due to different forms of utilization, constructional conditions, time of exposure, heating and ventilation conditions, additional aerosol sources, aerosol parameters, chemical substances, etc. In order to investigate the peculiarities of the radon situation in workplaces located inside buildings compared with that in dwellings, long-time recordings of radon, attached radon progeny and unattached radon progeny concentrations ( 218 Po, 214 Pb, 214 Bi) are carried out at several categories of workplaces (e.g. offices, social establishments, schools, production rooms, workshops, kitchens, agricultural facilities). 36 workplaces have been investigated. There have been carried out at least 2-3 long-time recordings for each workplace during different seasons. At the same time the gamma dose rate, meteorological conditions, aerosol particle concentrations have been registered. Many special dates from the workplaces and the buildings have been recorded. Activity size distribution of the aerosol-attached and unattached fraction of short-lived radon decay products have been determinated in 20 workplaces. Mainly the following measurement systems were used: Radon- and Radon Progeny Monitor EQF 3020, SARAD GmbH, Germany. Alpha-Track Radon Detectors, BfS Berlin, Germany. Screen Diffusion Batteries with Different Screens, University of Goettingen, Germany. Low-Pressure Cascade Impactor, Type BERNER. Condensation Nuclei Counter, General Electric, USA. PAEC-f p -Rn-Monitor, University of Goettingen, Germany. Through the measurements, many peculiarities in the course of the radon-concentration, the equilibrium factor F, the unattached fraction f p and the activity size distribution have been determined. These amounts are influenced mainly by the working conditions and the working intervals. The influence of these peculiarities in workplaces on the dose have

  19. Public perceptions of radon risk

    International Nuclear Information System (INIS)

    Mainous, A.G. III; Hagen, M.D.

    1993-01-01

    Since 1984, a significant amount of media attention has focused on health threats from radon gas exposure. Using a probability telephone survey of adults (n = 685), we studied public perceptions of risk from radon exposure versus other environmental health risks. The results indicated that 92% of those individuals who had heard of radon believe radon to be a health risk, although only 4% believe they are currently exposed to high levels of radon gas. Perception of risk from radon was positively related to other perceptions of environmental risks. Younger and less educated individuals were more likely to perceive radon as a health risk. Women were three-and-one-half times as likely as men to perceive risk from radon. However, there was no significant relationship between perceived risk from radon and cigarette smoking. Media attention has apparently led to public awareness of radon hazards, but further attention is needed to improve smokers' awareness of their special risks from radon

  20. Radon Research Program, FY 1991

    International Nuclear Information System (INIS)

    1992-03-01

    The scientific information being sought in this program encompasses research designed to determine radon availability and transport outdoors, modeling transport into and within buildings, physics and chemistry of radon and radon progeny, dose response relationships, lung cancer risk, and mechanisms of radon carcinogenesis. The main goal of the DOE/OHER Radon Research Program is to develop information to reduce these uncertainties and thereby provide an improved health risk estimate of exposure to radon and its progeny as well as to provide information useful in radon control strategies. Results generated under the Program were highlighted in a National Research Council report on radon dosimetry. The study concluded that the risk of radon exposure is 30% less in homes than in mines. This program summary of book describes the OHER FY-1991 Radon Research Program. It is the fifth in an annual series of program books designed to provide scientific and research information to the public and to other government agencies on the DOE Radon Research Program

  1. Absolute measurement method of environment radon content

    International Nuclear Information System (INIS)

    Ji Changsong

    1989-11-01

    A portable environment radon content device with a 40 liter decay chamber based on the method of Thomas double filter radon content absolute measurement has been developed. The correctness of the method of Thomas double filter absolute measurement has been verified by the experiments to measure the sampling gas density of radon that the theoretical density has been known. In addition, the intrinsic uncertainty of this method is also determined in the experiments. The confidence of this device is about 95%, the sensitivity is better than 0.37 Bqm -3 and the intrinsic uncertainty is less than 10%. The results show that the selected measuring and structure parameters are reasonable and the experimental methods are acceptable. In this method, the influence on the measured values from the radioactive equilibrium of radon and its daughters, the ratio of combination daughters to the total daughters and the fraction of charged particles has been excluded in the theory and experimental methods. The formula of Thomas double filter absolute measuring radon is applicable to the cylinder decay chamber, and the applicability is also verified when the diameter of exit filter is much smaller than the diameter of inlet filter

  2. Environmental radon

    International Nuclear Information System (INIS)

    Majumdar, S.K.; Schmalz, R.F.; Miller, E.W.

    1990-01-01

    This book covers many aspects of environmental radon, including: historical perspectives; occurrence and properties; detection, measurement, and mitigation, radon and health; and political, economic, and legislative impacts

  3. Radon exhalation of hardening concrete: monitoring cement hydration and prediction of radon concentration in construction site.

    Science.gov (United States)

    Kovler, Konstantin

    2006-01-01

    The unique properties of radon as a noble gas are used for monitoring cement hydration and microstructural transformations in cementitious system. It is found that the radon concentration curve for hydrating cement paste enclosed in the chamber increases from zero (more accurately - background) concentrations, similar to unhydrated cement. However, radon concentrations developed within 3 days in the test chamber containing cement paste were approximately 20 times higher than those of unhydrated cement. This fact proves the importance of microstructural transformations taking place in the process of cement hydration, in comparison with cement grain, which is a time-stable material. It is concluded that monitoring cement hydration by means of radon exhalation method makes it possible to distinguish between three main stages, which are readily seen in the time dependence of radon concentration: stage I (dormant period), stage II (setting and intensive microstructural transformations) and stage III (densification of the structure and drying). The information presented improves our understanding of the main physical mechanisms resulting in the characteristic behavior of radon exhalation in the course of cement hydration. The maximum value of radon exhalation rate observed, when cement sets, can reach 0.6 mBq kg(-1) s(-1) and sometimes exceeds 1.0 mBq kg(-1) s(-1). These values exceed significantly to those known before for cementitious materials. At the same time, the minimum ventilation rate accepted in the design practice (0.5 h(-1)), guarantees that the concentrations in most of the cases will not exceed the action level and that they are not of any radiological concern for construction workers employed in concreting in closed spaces.

  4. Radon thematic days - Conference proceedings

    International Nuclear Information System (INIS)

    2011-03-01

    This document brings together the available presentations given at the Radon thematic days organized by the French society of radiation protection (SFRP). Twenty five presentations (slides) are compiled in the document and deal with: 1 - General introduction about radon (Sebastien Baechler, IRA); 2 - Survey of epidemiological studies (Dominique Laurier, IRSN); 3 - Dosimetric model (Eric Blanchardon, Estelle Davesne, IRSN); 4 - Radon issue in Franche-Comte: measurement of the domestic exposure and evaluation of the associated health impact (Francois Clinard, InVS); 5 - WHO's (World Health Organization) viewpoint in limiting radon exposure in homes (Ferid Shannoun, OMS); 6 - Radon measurement techniques (Roselyne Ameon, IRSN); 7 - Quality of radon measurements (Francois Bochud, IRA); 8 - International recommendations (Jean-Francois Lecomte, IRSN); 9 - Radon management strategy in Switzerland - 1994-2014 (Christophe Murith, OFSP); 10 - 2011-2015 action plan for radon risk management (Jean-Luc Godet, Eric Dechaux, ASN); 11 - Radon at work place in Switzerland (Lisa Pedrazzi, SUVA); 12 - Strategies of radiation protection optimization in radon exposure situations (Cynthia Reaud, CEPN); 13 - Mapping of the radon potential of geologic formations in France (Geraldine Ielsch, IRSN); 14 - Radon database in Switzerland (Martha Gruson, OFSP); 15 - Radon 222 in taps water (Jeanne Loyen, IRSN); 16 - Buildings protection methods (Bernard Collignan, CSTB, Roselyne Ameon, IRSN); 17 - Preventive and sanitation measures in Switzerland (Claudio Valsangiacomo, SUPSI); 18 - Training and support approach for building specialists (Joelle Goyette-Pernot, Fribourg engineers and architects' school); 19 - Status of radon bulk activity measurements performed between 2005-2010 in public areas (Cyril Pineau, ASN); 20 - Neuchatel Canton experiments (Didier Racine, SENE); 21 - Montbeliard region experience in the radon risk management (Isabelle Netillard, Pays de Montbeliard Agglomeration); 22

  5. Radon measurement in the spa of Bizovac

    International Nuclear Information System (INIS)

    Faj, Z.; Radolic, V.; Suveljak, B.; Planinic, J.

    1996-01-01

    The spa of Bizovac is located 20 km on the west of Osijek in east Croatia. Radon concentrations in the air and water of the Bizovac spa were measured by the Radhome silicon detector and the average values were obtained as 70 Bq/m 3 in the indoor pool, 40 Bq/m 3 in the hotel room and 135 Bq/m 3 in the closed therapeutic bathroom. A special experiment was performed in a closed therapeutic bathroom by three bathtubes filled up with geothermal water as well as normal (potable) one from water-supply. Using measured radon concentrations in air by Radhome detector under the mentioned conditions in the closed bathroom, radon concentrations were assessed for the geothermal water as 25.3 Bq/m 3 and 2.7 Bq/m 3 for potable water. Radon in potable water, measured by the sampling glass ampoule and scintillation cell, had the concentration of 3.5 Bq/m 3 . The radon transfer factor from water to air in the indoor pool and therapeutic bathroom was 10 and 40 times higher than for normal dwelling factor (10 -4 ), respectively. The effective dose equivalent of inhaled radon for permanent personnel under the worst conditions in the spa (closed therapeutic bathroom) was 5.4 mSv/y, but visitors spending two weeks in the Bizovac spa could receive the dose of 77 μSv. (author)

  6. The influence of thoron on measurement results of radon exhalation rate

    CERN Document Server

    Xiao De Tao; Ling Qiu; Leung, J K C

    2002-01-01

    Because of thoron exhalation, the measurement results of radon exhalation rate using a local still method is usually larger than the true value of radon flux rate of the monitored material surface. The influence of sup 2 sup 1 sup 6 Po(ThA) on radon exhalation rate can be eliminated for sensitive radon monitors. Theoretical evaluations of the influence of sup 2 sup 1 sup 2 Bi(ThC) and sup 2 sup 1 sup 2 Po(ThC')on radon exhalation rate are carried out in a sampler with diameter of 188 mm, and height of 125 mm, and supplied electrostatic field inside (generated by high voltage and electret) under following conditions: the sampling time are 1, 2, 3 h, respectively, thoron exhalation rate is 100 times of radon's. The calculation results indicate that the measurement results of radon flux rate are possibly 35.5% larger than true value due to the influence of thoron for fast and multifunctional radon monitors with electret, high voltage, respectively and using CR-39 SSNTD as detector, but this influence is negligib...

  7. Radon occurrence in soil-gas and groundwater around an active landslide

    Energy Technology Data Exchange (ETDEWEB)

    Ramola, R.C. [Department of Physics, H.N.B. Garhwal University, Badshahi Thaul Campus, Tehri Garhwal -249 199 (India)], E-mail: rcramola@gmail.com; Choubey, V.M. [Wadia Institute of Himalayan Geology, Dehradun 248 001 (India); Negi, M.S.; Prasad, Yogesh; Prasad, Ganesh [Department of Physics, H.N.B. Garhwal University, Badshahi Thaul Campus, Tehri Garhwal -249 199 (India)

    2008-01-15

    This paper presents the results of investigation of radon levels in the soil-gas and groundwater of Uttarkashi, India within the distance of 5 km in vertical and horizontal directions from the landslide of Varunawat hill. Radon release from the soil and groundwater was found higher than the normal values. Radon concentration in groundwater over and around the landslide was found to vary from 0.51 to 86kBqm{sup -3}. The soil-gas radon concentration was found to vary from 219 to 3kBqm{sup -3} along the slope of landslide. Radon exhalation rate in collected soil samples was found to vary from 2.28x10{sup -5} to 9.01x10{sup -5}Bqkg{sup -1}h{sup -1}. Radon values were not found correlated with major and trace element contents in the upper soil of the area, which indicate that the migration of radon from deeper part of the earth along with landslide contribute to the surface radon concentration. Recorded values show a close association with local geology and Varunawat eruptions.

  8. Radon occurrence in soil-gas and groundwater around an active landslide

    International Nuclear Information System (INIS)

    Ramola, R.C.; Choubey, V.M.; Negi, M.S.; Prasad, Yogesh; Prasad, Ganesh

    2008-01-01

    This paper presents the results of investigation of radon levels in the soil-gas and groundwater of Uttarkashi, India within the distance of 5 km in vertical and horizontal directions from the landslide of Varunawat hill. Radon release from the soil and groundwater was found higher than the normal values. Radon concentration in groundwater over and around the landslide was found to vary from 0.51 to 86kBqm -3 . The soil-gas radon concentration was found to vary from 219 to 3kBqm -3 along the slope of landslide. Radon exhalation rate in collected soil samples was found to vary from 2.28x10 -5 to 9.01x10 -5 Bqkg -1 h -1 . Radon values were not found correlated with major and trace element contents in the upper soil of the area, which indicate that the migration of radon from deeper part of the earth along with landslide contribute to the surface radon concentration. Recorded values show a close association with local geology and Varunawat eruptions

  9. Determination of the Radon Concentration and Radioactivity Level in Karaca Cave

    International Nuclear Information System (INIS)

    Kara, A.

    2008-01-01

    In this study, the radon gas concentration in the Karaca cave which is open to tourism has been determined and the negative effects of radon gas on people were discussed. Karaca cave (Gumushane) is visited by many tourists every year. The measurements of radon gas concentration which affects the health of human beings negatively and even causes the lung cancer when it reaches high points have been done for the summer and winter season. LR-115 passive radon detector was used to determine radon concentrations in the cave both winter and summer season. The average radon concentration in the Karaca cave were determined as 823 Bq/m 3 and 1023 Bq/m 3 for the summer and winter season, respectively. Moreover, to find out the natural radioactivity in the cave, the gamma spectroscopic analysis of soil, stone and stalagmite samples were carried out and their relations with the radon gas in the cave atmosphere was analyzed

  10. Origin of radon concentration of Csalóka Spring in the Sopron Mountains (West Hungary)

    International Nuclear Information System (INIS)

    Freiler, Ágnes; Horváth, Ákos; Török, Kálmán; Földes, Tamás

    2016-01-01

    We examined the Csalóka Spring, which has the highest radon concentration in the Sopron Mountains (West Hungary) (, yearly average of 227 ± 10 Bq L"−"1). The main rock types here are gneiss and micaschist, formed from metamorphism of former granitic and clastic sedimentary rocks respectively. The aim of the study was to find a likely source of the high radon concentration in water. During two periods (2007–2008 and 2012–2013) water samples were taken from the Csalóka Spring to measure its radon concentration (from 153 ± 9 Bq L"−"1 to 291 ± 15 Bq L"−"1). Soil and rock samples were taken within a 10-m radius of the spring from debrish and from a deformed gneiss outcrop 500 m away from the spring. The radium activity concentration of the samples (between 24.3 ± 2.9 Bq kg"−"1 and 145 ± 6.0 Bq kg"−"1) was measured by gamma-spectroscopy, and the specific radon exhalation was determined using radon-chamber measurements (between 1.32 ± 0.5 Bq kg"−"1 and 37.1 ± 2.2 Bq kg"−"1). Based on these results a model calculation was used to determine the maximum potential radon concentration, which the soil or the rock may provide into the water. We showed that the maximum potential radon concentration of these mylonitic gneissic rocks (c_p_o_t = 2020 Bq L"−"1) is about eight times higher than the measured radon concentration in the water. However the maximum potential radon concentration for soils are significantly lower (41.3 Bq L"−"1) Based on measurements of radon exhalation and porosity of rock and soil samples we concluded that the source material can be the gneiss rock around the spring rather than the soil there. We determined the average radon concentration and the time dependence of the radon concentration over these years in the spring water. We obtained a strong negative correlation (−0.94 in period of 2007–2008 and −0.91 in 2012–2013) between precipitation and radon concentration. - Highlights: • A yearly dataset

  11. Radon in soil gas survey in Curitiba (Brazil)

    International Nuclear Information System (INIS)

    Paschuk, Sergei A.; Correa, Janine Nicolosi; Schelin, Hugo R.; Barbosa, Laercio; Sadula, Tatyana; Matsuzaki, Cristiana A.

    2009-01-01

    This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222 Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving vertically along the outside of the shaft. The equipment was adjusted with air flow of 0.03 L/min and the measurements were performed during 90 min approximately. The 222 Rn concentration levels were detected and analyzed by the computer every 5 minutes using the software DataEXPERT by GENITRON Instruments. Collected average levels of 222 Rn concentration were processed taking into account the internal volume of Soil Probe and connection vessels. Radon sampling was performed at a depth of 50 - 70 cm. Obtained experimental data of radon concentration present rather big variation but correlates perfectly with previously obtained results for 222 Rn activity in drinking water. Further measurements are planned to be performed at other regions of Parana State and will involve the mineral analysis of soil samples. (author)''

  12. Metrology and monitoring of radon, thoron and their daughter products

    International Nuclear Information System (INIS)

    1985-01-01

    The principles of measurement and monitoring are described as applied to radon- and thoron gases and their daughter products in occupational and non-occupational environments. Various methods of measurement, such as grab-sampling, continuous monitoring, integrated measurements and personal dosimetry are discussed. Uncertainties in different measurement methods are compared. An account of unattached fraction and plateout of radon daughters is included. General principles and guidelines for monitoring are presented for the purposes of practical radiation protection as well as research applications. Calibration aspects of measurement instruments are described and procedures for interlaboratory calibration are suggested. Sampling strategies for occupational and non-occupational environments are discussed and radiation protection training requirements are identified. Where sufficient information and consensus exist, guidelines on apparatus, methods and procedures for monitoring are provided. A summary of regulations in force or being developed and recommendations for monitoring radiation exposure to radon and its decay products in countries of the OECD is provided, together with cost estimates for national indoor radon surveys

  13. Radon in homes and other technologically enhanced radioactivity

    International Nuclear Information System (INIS)

    Rundo, J.; Toohey, R.E.

    1983-01-01

    The results are described of recent observations at Argonne National Laboratory, contributing to our knowledge of such factors as the origin of high levels of radon in houses, its variability with time or otherwise, its uniformity throughout the house or otherwise, and the behavior and fate of the short-lived daughter-products. In a sample of 110 houses, mostly in the west suburban area of Chicago, 15% had radon concentrations in excess of 6 pCi litre - 1 and 96% greater than 10 pCi litre - 1 . If this distribution is representative of all houses in the USA, the population being exposed to such high concentrations of radon is far greater than the number of people in Grand Junction being exposed to quite similar concentrations from technologically enhanced radioactivity. There is a great need for far more extensive data on radon in houses

  14. Radon in Estonian dwellings - Results from a National Radon Survey

    Energy Technology Data Exchange (ETDEWEB)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo [Estonian Radiation Protection Centre (Kiirguskeskus), Tallinn (Spain); Aakerblom, Gustav [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m{sup 3}, in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m{sup 3}. In 1% of the dwellings the radon concentration exceeded 400 Bq/m{sup 3}. The highest radon concentration found in the study was 1040 Bq/m{sup 3}. Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m{sup 3}, and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m{sup 3}. The mean value for all Estonia dwellings is calculated

  15. Radon in Estonian dwellings - Results from a National Radon Survey

    International Nuclear Information System (INIS)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo; Aakerblom, Gustav

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m 3 , in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m 3 . In 1% of the dwellings the radon concentration exceeded 400 Bq/m 3 . The highest radon concentration found in the study was 1040 Bq/m 3 . Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m 3 , and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m 3 . The mean value for all Estonia dwellings is calculated to be 60 Bq/m 3 . Using

  16. Radon-film-badges by solid radiators to complement track detector-based radon monitors

    International Nuclear Information System (INIS)

    Tommasino, L.; Tommasino, M.C.; Viola, P.

    2009-01-01

    Existing passive radon monitors, based on track detectors, present many shortcomings, such as a limited response sensitivity for one-week-indoor measurements and a limited response linearity for the assessment of large radon exposures indoors, in thermal spa, in caves, and in soil. Moreover, for in-soil measurements these monitors are too bulky and are often conducive to wrong results. For what concerns the radon-in-water measurements, they are just not suitable. A new generation of passive radon monitors is introduced in this paper, which are very similar to the compact badges used in neutron- and gamma-dosimetry and will be referred to as radon-film-badges. These film-badges are formed by thin-film radiators with suitable radon-sorption characteristics, facing track detectors. The key strategy adopted for these radiators is to exploit an equilibrium type of radon sorption in solids. Even though this new generation of passive monitors is at its infancy, it appears already clear that said monitors make it finally possible to overcome most of the shortcomings of existing passive radon monitors. These devices are uniquely simple and can be easily acquired by any existing radon service to complement their presently used passive radon monitors with little or no effort.

  17. Radon in buildings

    International Nuclear Information System (INIS)

    Connell, J.J.

    1991-01-01

    This guide is intended to inform designers, householders and other building owners about the radon problem and to help in deciding if there is need to take any action to reduce radon levels in their homes or other buildings.It explains what radon is, how it enters buildings and what effect it may have on health. Reference is made to some of the usual ways of reducing the level of radon and guidance is given on some sources of assistance

  18. Predictors of Indoor Radon Concentrations in Pennsylvania, 1989-2013.

    Science.gov (United States)

    Casey, Joan A; Ogburn, Elizabeth L; Rasmussen, Sara G; Irving, Jennifer K; Pollak, Jonathan; Locke, Paul A; Schwartz, Brian S

    2015-11-01

    Radon is the second-leading cause of lung cancer worldwide. Most indoor exposure occurs by diffusion of soil gas. Radon is also found in well water, natural gas, and ambient air. Pennsylvania has high indoor radon concentrations; buildings are often tested during real estate transactions, with results reported to the Department of Environmental Protection (PADEP). We evaluated predictors of indoor radon concentrations. Using first-floor and basement indoor radon results reported to the PADEP between 1987 and 2013, we evaluated associations of radon concentrations (natural log transformed) with geology, water source, building characteristics, season, weather, community socioeconomic status, community type, and unconventional natural gas development measures based on drilled and producing wells. Primary analysis included 866,735 first measurements by building, with the large majority from homes. The geologic rock layer on which the building sat was strongly associated with radon concentration (e.g., Axemann Formation, median = 365 Bq/m3, IQR = 167-679 vs. Stockton Formation, median = 93 Bq/m3, IQR = 52-178). In adjusted analysis, buildings using well water had 21% higher concentrations (β = 0.191, 95% CI: 0.184, 0.198). Buildings in cities (vs. townships) had lower concentrations (β = -0.323, 95% CI: -0.333, -0.314). When we included multiple tests per building, concentrations declined with repeated measurements over time. Between 2005 and 2013, 7,469 unconventional wells were drilled in Pennsylvania. Basement radon concentrations fluctuated between 1987 and 2003, but began an upward trend from 2004 to 2012 in all county categories (p Pennsylvania, 1989-2013. Environ Health Perspect 123:1130-1137; http://dx.doi.org/10.1289/ehp.1409014.

  19. Radon surveys and monitoring at active volcanoes: an open window on deep hydrothermal systems and their dynamics

    Science.gov (United States)

    Cigolini, Corrado; Laiolo, Marco; Coppola, Diego

    2017-04-01

    The behavior of fluids in hydrothermal systems is critical in volcano monitoring and geothermal prospecting. Analyzing the time series of radon emissions on active volcanoes is strategic for detecting and interpreting precursory signals of changes in volcanic activity, eventually leading to eruptions. Radon is a radioactive gas generated from the decay of U bearing rocks, soils and magmas. Although radon has been regarded as a potential precursor of earthquakes, radon anomalies appear to be better suited to forecast volcanic eruptions since we know where paroxysms may occur and we can follow the evolution of volcanic activity. Radon mapping at active volcanoes is also a reliable tool to assess diffuse and concentrated degassing as well as efficiently detecting earthquake-volcano interactions. Systematic radon monitoring has been shown to be a key factor for evaluating the rise of volcanic and hydrothermal fluids. In fact, the decay properties of radon, the duration of radon anomalies together with sampling rates may be cross-checked with the chemistry of hydrothermal fluids (and their transport properties) to constrain fluids ascent rates and to infer the permeability and porosity of rocks in sectors surrounding the active conduits. We hereby further discuss the data of radon surveys and monitoring at Somma-Vesuvius, Stromboli and La Soufrière (Guadeloupe, Lesser Antilles). The integrated analysis of seismic and geochemical data, including radon emissions, may be successfully used in testing temperature distributions and variations of porosity and permeability in volcanic hydrothermal systems and can be used as a proxy to analyze geothermal reservoirs.

  20. Radon and its hazards

    International Nuclear Information System (INIS)

    Chang Guilan

    2002-01-01

    The author describes basic physical and chemical properties of radon and the emanation, introduces methods of radon measurement, expounds the hazards of non-mine radon accumulation to the health of human being and the protection, as well as the history how the human being recognizes the hazards of radon through the specific data and examples, and finally proposes protecting measures to avoid the hazards of radon to the health of human being, and to do ecologic evaluation of environments

  1. Portable devices for monitoring radon and its progeny in air

    International Nuclear Information System (INIS)

    Zhang Huaiqin; Yao Wanyuan; Su Jingling; Liu Jinhua

    1990-01-01

    We have developed two kinds of portable monitoring devices to measure the concentration and potential energy concentration of radon and its progeny in air. The thermoluminescence material CaSO4 (Tm) is used as the detection element. One of the devices is called passive radon monitor. The lowest detectable limit for radon in air is about 1.5 Bq/m 3 , as a sampling time being one week. Good reliability and ease to operate are its main advantages. The second kind of device is called a working level monitor which consists of a miniature remembrane pump and an integrating sampling probe. The lowest detectable limit is about 0.00043 WL (9x10 -9 J/m 3 ) for a sampling time of 6 hours. It weighs only 0.35 kg, but maintenance is necessary sometimes. (author). 6 refs, 2 figs, 4 tabs

  2. Radon concentrations in homes in an area of dolomite bedrock: Door County, Wisconsin

    International Nuclear Information System (INIS)

    Hawk, K.; Stieglitz, R.D.; Norman, J.C.

    1993-01-01

    A statewide survey by the Wisconsin Department of Health and Social Services with U.S.E.P.A. assistance reported an anomalously high percentage of homes in Door County with radon concentrations in excess of 20 pCi/L. The results were of interest because the county is underlain by marine sedimentary rocks rather than the igneous and metamorphic crystalline types usually associated with elevated radon concentrations. A voluntary population of 55 homes was tested for radon using activated charcoal canisters. This population was also asked to provide questionnaire response data on family, home, and socioeconomic aspects. The data were separated into socioeconomic, energy efficiency, radon access, and karst level categories and statistically analyzed. A subpopulation was selected from the larger population for detailed site investigation, which included additional in-home air testing and, at some sites, water supply analysis and in-ground testing for radon. The field investigations collected information on the geology, soil, topography, and home construction and use. The results of the investigation verified and characterized the radon occurrences in Door County. The presence or absence of karst features is shown to be statistically significant to radon levels. 23 refs., 5 figs., 3 tabs

  3. S. 2844: A Bill to provide for radon testing. Introduced in the Senate of the United States, One Hundredth Congress, Second Session, September 29, 1988

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Bill S. 2844 provides for radon testing and is cited as the Department of Housing and Urban Development Policy Act. The bill provides the Department of Housing and Urban Development (HUD) with a mandate to establish a departmental radon policy and program. The department will be required to use its programs to assist the Environmental Protection Agency (EPA) address radon contamination. The bill also requires HUD, in coordination with the EPA, to develop a radon assessment and mitigation program which utilizes EPA recommended guidelines and standards to ensure that occupants of housing covered under this act are not exposed to elevated levels of radon. The entire contents of the bill are presented in eight sections entitled: Short Title, findings, Purpose, Definitions, Program, Information, Cooperation with Environmental Protection Agency, and Authorization. The bill was referred to the Committee on Banking, Housing and Urban Affairs

  4. The April 1994 and October 1994 radon intercomparisons at EML

    International Nuclear Information System (INIS)

    Fisenne, I.M.; George, A.C.; Perry, P.M.; Keller, H.W.

    1995-10-01

    Quality assurance/quality control (QA/QC) are the backbone of many commercial and research processes and programs. QA/QC research tests the state of a functioning system, be it the production of manufactured goods or the ability to make accurate and precise measurements. The quality of the radon measurements in the US have been tested under controlled conditions in semi-annual radon gas intercomparison exercises sponsored by the Environmental Measurements Laboratory (EML) since 1981. The two Calendar Year 1994 radon gas intercomparison exercises were conducted in the EML exposure chamber. Thirty-two groups including US Federal facilities, USDOE contractors, national and state laboratories, universities and foreign institutions participated in these exercises. The majority of the participant's results were within ±10% of the EML value at radon concentrations of 570 and 945 Bq m -3

  5. Radon reduction

    International Nuclear Information System (INIS)

    Hamilton, M.A.

    1990-01-01

    During a radon gas screening program, elevated levels of radon gas were detected in homes on Mackinac Island, Mich. Six homes on foundations with crawl spaces were selected for a research project aimed at reducing radon gas concentrations, which ranged from 12.9 to 82.3 pCi/l. Using isolation and ventilation techniques, and variations thereof, radon concentrations were reduced to less than 1 pCi/l. This paper reports that these reductions were achieved using 3.5 mil cross laminated or 10 mil high density polyethylene plastic as a barrier without sealing to the foundation or support piers, solid and/or perforated plastic pipe and mechanical fans. Wind turbines were found to be ineffective at reducing concentrations to acceptable levels. Homeowners themselves installed all materials

  6. Soil gas radon response to environmental and soil physics variables

    International Nuclear Information System (INIS)

    Thomas, D.M.; Chen, C.; Holford, D.

    1991-01-01

    During the last three years a field study of soil gas radon activities conducted at Poamoho, Oahu, has shown that the primary environmental variables that control radon transport in shallow tropical soils are synoptic and diurnal barometric pressure changes and soil moisture levels. Barometric pressure changes drive advective transport and mixing of soil gas with atmospheric air; soil moisture appears to control soil porosity and permeability to enhance or inhibit advective and diffusive radon transport. An advective barrier test/control experiment has shown that advective exchange of soil gas and air may account for a substantial proportion of the radon loss from shallow soils but does not significantly affect radon activities at depths greater than 2.3 m. An irrigation test/control experiment also suggests that, at soil moisture levels approaching field capacity, saturation of soil macroporosity can halt all advective transport of radon and limit diffusive mobility to that occurring in the liquid phase. The results of the authors field study have been used to further refine and extend a numerical model, RN3D, that has been developed by Pacific Northwest Laboratories to simulate subsurface transport of radon. The field data have allowed them to accurately simulate the steady state soil gas radon profile at their field site and to track transient radon activities under the influence of barometric pressure changes and in response to changes in soil permeability that result from variations in soil moisture levels. Further work is continuing on the model to enable it to properly account for the relative effects of advective transport of soil gas through cracks and diffusive mobility in the bulk soils

  7. Radon level and radon effective dose rate determination in Moroccan dwellings using SSNTDs

    International Nuclear Information System (INIS)

    Oufni, L.; Misdaq, M.A.; Amrane, M.

    2005-01-01

    Inhalation of radon ( 222 Rn) and its daughter product are a major source of natural radiation exposure. The measurement of radon activity in dwelling is assuming ever increasing importance. It is known from recent surveys in many countries that radon and its progeny contribute significantly to total inhalation dose and it is fairly established that radon when inhaled in large quantity causes lung disorder. Keeping this in view, the indoor radon activity level and radon effective dose rate were carried out in the dwellings of Beni-Mellal, Khouribgra and Ben Guerir cities, Morocco, using the solid state nuclear track detectors (SSNTD) technique. Assuming an indoor occupancy factor of 0.8 and 0.4 for the equilibrium factor of radon indoors, we found that the 222 Rn effective dose rate in the studied dwellings ranges from 1.01 to 7.90mSvy -1 . The radon activity in the corresponding dwellings was found to vary from 40 to 532Bqm -3 . The radon activity has not only been found to vary with seasonal changes, but also with the age, the construction mode of houses, the ventilation conditions and with specific sites and geological materials

  8. Primary functions of the first Japanese large-scale facility for exposing small animals to radon

    International Nuclear Information System (INIS)

    Ishimori, Yuu; Tanaka, Hiroshi; Mitsunobu, Fumihiro; Yamaoka, Kiyonori; Kataoka, Takahiro; Sakoda, Akihiro

    2010-01-01

    The Japan Atomic Energy Agency (JAEA) and Okayama University have carried out the experimental animal study and its related studies since 2007 in order to examine the physiological effects of radon in detail. Thus, a radon test facility for small animals was developed in order to increase the statistical certainty of our animal tests. This paper illustrates the performances of that facility, the first large-scale facility of its types in Japan. The facility has a potential of approximately 150 mouse-scale tests at the same time. The apparatus for exposing small animals to radon has six animal chamber groups each of which consists of five independent cages. Different radon concentrations in each animal chamber group are available. The major functions of the facility controlling radon and avoiding thoron were shown theoretically and experimentally. The relative standard deviation of radon concentration at the highest concentration group was about 5%, although the lower concentration groups seemed to be affected by variations in background radon. (author)

  9. EML indoor radon workshop, 1982

    International Nuclear Information System (INIS)

    George, A.C.; Lowder, W.; Fisenne, I.; Knutson, E.O.; Hinchliffe, L.

    1983-07-01

    A workshop on indoor radon, held at the Environmental Measurements Laboratory (EML) on November 30 and December 1, 1982, covered recent developments in radon daughter research and development. Thirty papers were presented dealing with standardization and quality assurance measurement methods, surveys, measurements strategy, physical mechanisms of radon and radon daughter transport and development of guidance standards for indoor exposures. The workshop concluded with a planning session that identified the following needs: (1) national and international intercomparisons of techniques for measuring radon and radon daughter concentrations, working level and radon exhalation flux density; (2) development and refinement of practical measurement techniques for thoron and its daughter products; (3) quantitative definition of the sources of indoor radon and the mechanisms of transport into structures; (4) better knowledge of the physical properties of radon daughters; (5) more complete and accurate data on the population exposure to radon, which can only be met by broadly based surveys; and (6) more international cooperation and information exchange among countries with major research programs

  10. A cost-effectiveness analysis of radon protection methods in domestic properties: a comparative case study in Brixworth, Northamptonshire, UK

    International Nuclear Information System (INIS)

    Coskeran, Thomas; Denman, Antony; Phillips, Paul; Tornberg, Roger

    2006-01-01

    Building regulations in the UK have since 1992 required that radon-proof membranes be installed in new domestic properties to protect residents against the adverse effects of radon. This study compares the cost-effectiveness of the current regulatory regime with an alternative that would entail new properties being tested for radon after construction, and being remediated if necessary. The alternative regime is found to be more cost-effective for a sample of properties in Brixworth, Northamptonshire, UK. For this regime, the central estimate of cost per quality-adjusted life-year gained, the measure of cost-effectiveness used, is Pounds 2869 compared to Pounds 6182 for installing membranes, results suggesting a case for re-examining the current regulations on radon protection in new properties. Pilot studies will, however, be needed to consider how different means of protecting residents of new properties against radon might operate in practice and to provide improved evidence on their relative cost-effectiveness

  11. Air radon equilibrium factor measurement in a Waste Water Pre-Treatment Plant

    International Nuclear Information System (INIS)

    Martinez, J.E.; Juste, B.; Ortiz, J.; Martorell, S.; Verdu, G.

    2017-01-01

    We analyze in this paper a Waste Water Pre-Treatment Plant (WWTP) located at the Mediterranean coast with air radon concentration above Spanish action level (600 Bq per cubic meter). This paper presents a method for radon equilibrium determination by gamma spectrometry measuring of the radon progeny concentrations in the air, in order to estimate WWTP workers effective dose more exactly. The method is based on simultaneous sampling of air through a filter paper and alpha spectrometry measurement of radon activity concentration in the air. According to the measured radon activity concentration in the air of 368±45 Bq/m 3 the equilibrium factor between radon and progenies is estimated to be F=0.27, which is in good agreement with expected values. - Highlights: • High levels of Radon in a workplace can increase health risks in the employees. • Using the typical equilibrium factor 0.4 could lead to an error in the estimation of radon doses. • We present a method for radon equilibrium determination. • Equilibrium factor is calculated by gamma spectrometry measuring of radon progeny concentrations in the air.

  12. Research on groundwater radon as a fluid phase precursor to earthquakes

    International Nuclear Information System (INIS)

    Teng, T.; Sun, L.

    1986-01-01

    Groundwater radon monitoring work carried out in southern California by the University of Southern California since 1974 is summarized here. This effort began with a sampling network over a locked segment of the San Andreas fault from Tejon to Cajon and was later expanded to cover part of the southern Transverse Mountain ranges. Groundwater samples were brought back weekly to the laboratory for high precision scintillation counting. Needs for more frequent sampling and less labor prompted the development of an economical and field worthy instrument known as the continuous radon monitor. About 10 have been installed in the network since early 1980. The groundwater radon content was found to show anomalous increases (mostly at a single station) before a number of moderate and nearby earthquakes. Our work is hampered by a lack of large earthquakes that may have a regional impact on radon anomalies and by the complexity of the underground hydrological regime. To circumvent this difficulty, we have chosen to monitor only deep artesian wells or hot spring wells

  13. Relationship between indoor radon and lung cancer: a study of feasibility of an epidemiological study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, S.; Neuberg, D.; DuMouchel, W.; Kleitman, D.; Chernoff, H.

    1981-01-01

    This report describes a study to assess the feasibility of an epidemiologic investigation of the relationship between residential radon exposure and lung cancer. Field measurements of residential radon levels in the State of Maine are described. Using these radon measurements and BEIR, 1980 risk assessments, it is estimated that at most 10% of lung cancers in Maine can be considered attributable to residential radon exposure. Calculations are made of sample sizes necessary for a case-control study of radon and lung cancer, for several levels of radon and smoking health effects. The effects of misclassification of exposure variables on the probability of detecting a radon health effect are discussed. A comparison is made of three different mathematical models which could be used for sample size estimation. Dollar cost estimates are given for conducting an epidemiologic case-control study of the relationship between residential radon exposure and lung cancer.

  14. Relationship between indoor radon and lung cancer: a study of feasibility of an epidemiological study. Final report

    International Nuclear Information System (INIS)

    Rasmussen, S.; Neuberg, D.; DuMouchel, W.; Kleitman, D.; Chernoff, H.

    1981-01-01

    This report describes a study to assess the feasibility of an epidemiologic investigation of the relationship between residential radon exposure and lung cancer. Field measurements of residential radon levels in the State of Maine are described. Using these radon measurements and BEIR, 1980 risk assessments, it is estimated that at most 10% of lung cancers in Maine can be considered attributable to residential radon exposure. Calculations are made of sample sizes necessary for a case-control study of radon and lung cancer, for several levels of radon and smoking health effects. The effects of misclassification of exposure variables on the probability of detecting a radon health effect are discussed. A comparison is made of three different mathematical models which could be used for sample size estimation. Dollar cost estimates are given for conducting an epidemiologic case-control study of the relationship between residential radon exposure and lung cancer

  15. QA/QC For Radon Concentration Measurement With Charcoal Canister

    International Nuclear Information System (INIS)

    Pantelic, G.; Zivanovic, M.; Rajacic, M.; Krneta Nikolic, J.; Todorovic, D.

    2015-01-01

    The primary concern of any measuring of radon or radon progeny must be the quality of the results. A good quality assurance program, when properly designed and diligently followed, ensures that laboratory staff will be able to produce the type and quality of measurement results which is needed and expected. Active charcoal detectors are used for testing the concentration of radon in dwellings. The method of measurement is based on radon adsorption on coal and measurement of gamma radiation of radon daughters. Upon closing the detectors, the measurement was carried out after achieving the equilibrium between radon and its daughters (at least 3 hours) using NaI or HPGe detector. Radon concentrations as well as measurement uncertainties were calculated according to US EPA protocol 520/5-87-005. Detectors used for the measurements were calibrated by 226Ra standard of known activity in the same geometry. Standard and background canisters are used for QA and QC, as well as for the calibration of the measurement equipment. Standard canister is a sealed canister with the same matrix and geometry as the canisters used for measurements, but with the known activity of radon. Background canister is a regular radon measurement canister, which has never been exposed. The detector background and detector efficiency are measured to ascertain whether they are within the warning and acceptance limits. (author).

  16. Continual monitoring of radon decay products concentration in indoor and outdoor air

    International Nuclear Information System (INIS)

    Petruf, P.; Holy, K.; Stanys, T.

    1998-01-01

    The goal of this work was the development of the method and construction and testing of measurement device for continual monitoring of radon daughters concentrations in the indoor and outdoor environment with regard to make possible to determine very low activities in the outdoor air (below % Bq/m 3 ). In this method air sample is drawn through the appropriate filter material. Radon and thoron daughters both attached and unattached on aerosols particles are collected on the filter surface and then the filter activity is counted. The silicon surface barrier detector with the active area of 200 mm 2 in monitor was used. The Millipore AW19-type filter was chosen and sampling rate of 30 l/min for collecting of the air samples. The determination of the individual activity concentrations in three-count method is based on the solution of the simultaneous equations describing the number of atoms of measured nuclides on the filter during and after sampling. The monitor was tested in three different environments (the average values of the activity concentrations of radon and its decay products in Bq/m 3 are given): in the basement of the building: 61.4 ± 5.0 of 222 Rn, 29.5 ± 2.8 of 218 Po, 14.1 ± 1.8 of 214 Pb and 12.1 ± 1.6 of 214 Bi; in the room on the second floor of the same building:22.2 ± 7.9 of 222 Rn, 7.3 ± 2.8 of 218 Po, 4.6 ± 1.9 of 214 Pb and 2.6 ± 1.2 of 214 Bi ; in the outdoor air in front of the building: 4.1 ± 2.7 of 222 Rn, 2.3 ± 0.9 of 218 Po, 1.5 ± 0.8 of 214 Pb and 1.4 ± 0.6 of 214 Bi. The results show a good agreement with expectations of the activity concentrations in three different environments. The monitor enables to determine low activity concentrations in the outdoor with an acceptable precision during one hour counting. The monitor can be used for the research of the correlation between the atmospheric stability and activity concentrations of radon decay products

  17. Radon therapy; Radon in der Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Spruck, Kaija [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-04-01

    Radon therapies are used since more than 100 years in human medicine. Today this method is controversially discussed due to the possible increase of ionizing radiation induced tumor risk. Although the exact mode of biological radiation effect on the cell level is still not known new studies show the efficiency of the radon therapy without side effect for instance for rheumatic/inflammatory or respiratory disorders.

  18. Indoor radon in rural dwellings of the South-Pannonian region

    International Nuclear Information System (INIS)

    Forkapic, S.; Bikit, I.; Slivka, J.; Conkic, L.; Veskovic, M.; Todorovic, N.; Varga, E.; Mrdda, D.; Hulber, E.

    2007-01-01

    The results of indoor radon survey in the South-Pannonian Province Vojvodina (Serbia and Montenegro) are presented. The sampling strategy was oriented towards suburban and urban regions in the Province. For the dwellings typical for such regions the geometric mean annual radon activity concentration of 76.1 Bq m -3 is measured (1000 measurements). This result leads to the annual dose estimate of 4.3 mSv y -1 , which is above the recommended action limit of ICRP. For urban dwellings in Novi Sad (the Province capital), the annual mean value of 54 Bq m -3 (220 measurements) is obtained. By comparison of these two results it is concluded that radon surveys based on measurements in urban environment may seriously underestimate the radon-related health risk. The elevated radon levels could not be explained by elevated uranium levels of surface soil. (authors)

  19. Radon in Norwegian dwellings

    International Nuclear Information System (INIS)

    Strand, T.; Green, B.M.R; Lomas, P.R.; Mangnus, K.; Stranden, E.

    1991-01-01

    Measurements of radon in indoor air have been made in a total of about 7500 randomly selected dwellings in Norway from all parts of the country. The number of selected dwellings in each municipality is about proportional to its population, except for the two largest municipalities, Oslo and Bergen, where somewhat smaller samples were taken due to the higher population density. The measurements were performed by nuclear track detectors from the National Radiological Protection Boards in United Kingdom, and the integration time for the measurements was 6 months. The detectors were spread evenly over all seasons of the year to eliminate influence from seasonal variation in the radon level. One single measurement was performed in each dwelling: in the main bedroom. The results shows that the distribution of radon concentrations in Norwegian bedrooms is log-normal. The aritmetic mean of the measurements, including all categories of dwellings, is calculated to be 51 Bq/m 3 and the corresponding geometric mean to be 26 Bq/m 3 . In a large proportion of single-family houses the living room and the kitchen are located on the ground floor while the bedrooms are located one floor higher. The results of the study shows that the radon level is somewhat higher at the ground floor than on the first floor, and higher in the basement than on the first floor. Taking this into account, and assuming that measurements in bedrooms on the first floor is a representative average for living room and kitchen, the average radon concentration for Norwegian dwellings is estimated to be between 55-65 Bq/m 3 . In this estimate, possible influences of the fact that the winters 87/88 and 88/89 were much warmer than normal and may therefor have lowered the results, has been taken into account. 15 refs., 9 figs., 15 tabs

  20. Suggestions for inclulsion of radon exhalation control target in building materials radioactivity standards

    International Nuclear Information System (INIS)

    Liu Fudong; Liu Senlin; Pan Ziqiang; Zhang Yonggui

    2010-01-01

    The specific-activity and radon exhalation rate from 26 building material samples from different areas were measured with high pure germanium (HPGe) gamma spectrometer and activated carbon cartridge. It is shown that the radium content is not completely relevant to radon exhalation rate from some building material. The existing national standards on 'The Limit of Radionuclides in Building Materials' (GB 6566-2001) only present internal exposure index as control target but not for radon exhalation rate; in fact, the radon exhalation rate from building materials is closely nearly related to indoor radon concentration. So we suggest that the radon exhalation control target should be included in the national standards on 'The Limit of Radionuclides in Building Materials'. (authors)