WorldWideScience

Sample records for sample orientation manual

  1. Extension of an Object-Oriented Optimization Tool: User's Reference Manual

    Science.gov (United States)

    Pak, Chan-Gi; Truong, Samson S.

    2015-01-01

    The National Aeronautics and Space Administration Armstrong Flight Research Center has developed a cost-effective and flexible object-oriented optimization (O (sup 3)) tool that leverages existing tools and practices and allows easy integration and adoption of new state-of-the-art software. This object-oriented framework can integrate the analysis codes for multiple disciplines, as opposed to relying on one code to perform analysis for all disciplines. Optimization can thus take place within each discipline module, or in a loop between the O (sup 3) tool and the discipline modules, or both. Six different sample mathematical problems are presented to demonstrate the performance of the O (sup 3) tool. Instructions for preparing input data for the O (sup 3) tool are detailed in this user's manual.

  2. Automatic sample changers maintenance manual

    International Nuclear Information System (INIS)

    Myers, T.A.

    1978-10-01

    This manual describes and provides trouble-shooting aids for the Automatic Sample Changer electronics on the automatic beta counting system, developed by the Los Alamos Scientific Laboratory Group CNC-11. The output of a gas detector is shaped by a preamplifier, then is coupled to an amplifier. Amplifier output is discriminated and is the input to a scaler. An identification number is associated with each sample. At a predetermined count length, the identification number, scaler data plus other information is punched out on a data card. The next sample to be counted is automatically selected. The beta counter uses the same electronics as the prior count did, the only difference being the sample identification number and sample itself. This manual is intended as a step-by-step aid in trouble-shooting the electronics associated with positioning the sample, counting the sample, and getting the needed data punched on an 80-column data card

  3. Dynamic delivery of the National Transit Database Sampling Manual.

    Science.gov (United States)

    2013-02-01

    This project improves the National Transit Database (NTD) Sampling Manual and develops an Internet-based, WordPress-powered interactive Web tool to deliver the new NTD Sampling Manual dynamically. The new manual adds guidance and a tool for transit a...

  4. Orientation manual for INIS and AGRIS (OMINAS)

    International Nuclear Information System (INIS)

    Binggeli, M.H.

    1979-01-01

    The manual is intended as a basic introduction to the computerized information systems, INIS (International Nuclear Information System) and AGRIS (International Information System for the Agricultural Sciences and Technology). Both systems contain information on already published literature, and include non-conventional literature (i.e. literature not available through normal commercial channels). Full bibliographic details and a subject classification are given. INIS, in addition, supplies descriptors, data-flagged where appropriate, and abstracts with every item of literature reported. The guiding principle followed by INIS and AGRIS is one of shared responsibility in development and operation. Both input is decentralized. The collection and preparation of documents relevant to the defined subject scopes are the responsibility of the country of publication. This decentralized input is transmitted to Vienna where centralized processing, merging and dispatching take place. The main output products are two printed journals, INIS Atomindex and AGRINDEX, and magnetic tape services. The manual is divided into four parts. The first is intended as a general introduction, and gives a bird's-eye view of the principles involved in the operation of the two systems. The second and third deal with INIS and AGRIS, respectively, and offer orientation in greater depth. The last part deals with the computer aspects of the system. The manual contains several appendices, a subject index and a list of basic references

  5. Sexual Socialisation in Life Orientation Manuals versus Popular Music: Responsibilisation versus Pleasure, Tension and Complexity

    Science.gov (United States)

    Macleod, Catriona; Moodley, Dale; Young, Lisa Saville

    2015-01-01

    This paper compares two forms of sexual socialisation to which learners are exposed: the sexuality education components of the Life Orientation (LO) manuals and the lyrical content and videos of popular songs. We performed a textual analysis of the sexual subject positions made available in, first, the LO manuals used in Grade 10 classes and,…

  6. Uranium tailings sampling manual

    International Nuclear Information System (INIS)

    Feenstra, S.; Reades, D.W.; Cherry, J.A.; Chambers, D.B.; Case, G.G.; Ibbotson, B.G.

    1985-01-01

    The purpose of this manual is to describe the requisite sampling procedures for the application of uniform high-quality standards to detailed geotechnical, hydrogeological, geochemical and air quality measurements at Canadian uranium tailings disposal sites. The selection and implementation of applicable sampling procedures for such measurements at uranium tailings disposal sites are complicated by two primary factors. Firstly, the physical and chemical nature of uranium mine tailings and effluent is considerably different from natural soil materials and natural waters. Consequently, many conventional methods for the collection and analysis of natural soils and waters are not directly applicable to tailings. Secondly, there is a wide range in the physical and chemical nature of uranium tailings. The composition of the ore, the milling process, the nature of tailings depositon, and effluent treatment vary considerably and are highly site-specific. Therefore, the definition and implementation of sampling programs for uranium tailings disposal sites require considerable evaluation, and often innovation, to ensure that appropriate sampling and analysis methods are used which provide the flexibility to take into account site-specific considerations. The following chapters describe the objective and scope of a sampling program, preliminary data collection, and the procedures for sampling of tailings solids, surface water and seepage, tailings pore-water, and wind-blown dust and radon

  7. The Design and Development of a Technology Based Orientation Manual for Clinical Research Coordinators

    Science.gov (United States)

    Copp, Susan L.

    2010-01-01

    The objective of this research was to use technology to develop an on-line orientation manual for clinical research coordinators. Many clinical research coordinators begin their careers as staff nurses and have little knowledge related to clinical research. As such, when they transition to a career in clinical research they lack the knowledge…

  8. Automatic Samples Selection Using Histogram of Oriented Gradients (HOG Feature Distance

    Directory of Open Access Journals (Sweden)

    Inzar Salfikar

    2018-01-01

    Full Text Available Finding victims at a disaster site is the primary goal of Search-and-Rescue (SAR operations. Many technologies created from research for searching disaster victims through aerial imaging. but, most of them are difficult to detect victims at tsunami disaster sites with victims and backgrounds which are look similar. This research collects post-tsunami aerial imaging data from the internet to builds dataset and model for detecting tsunami disaster victims. Datasets are built based on distance differences from features every sample using Histogram-of-Oriented-Gradient (HOG method. We use the longest distance to collect samples from photo to generate victim and non-victim samples. We claim steps to collect samples by measuring HOG feature distance from all samples. the longest distance between samples will take as a candidate to build the dataset, then classify victim (positives and non-victim (negatives samples manually. The dataset of tsunami disaster victims was re-analyzed using cross-validation Leave-One-Out (LOO with Support-Vector-Machine (SVM method. The experimental results show the performance of two test photos with 61.70% precision, 77.60% accuracy, 74.36% recall and f-measure 67.44% to distinguish victim (positives and non-victim (negatives.

  9. Sampling large landscapes with small-scale stratification-User's Manual

    Science.gov (United States)

    Bart, Jonathan

    2011-01-01

    This manual explains procedures for partitioning a large landscape into plots, assigning the plots to strata, and selecting plots in each stratum to be surveyed. These steps are referred to as the "sampling large landscapes (SLL) process." We assume that users of the manual have a moderate knowledge of ArcGIS and Microsoft ® Excel. The manual is written for a single user but in many cases, some steps will be carried out by a biologist designing the survey and some steps will be carried out by a quantitative assistant. Thus, the manual essentially may be passed back and forth between these users. The SLL process primarily has been used to survey birds, and we refer to birds as subjects of the counts. The process, however, could be used to count any objects. ®

  10. Manual for the sampling of uranium mine tailings

    International Nuclear Information System (INIS)

    Feenstra, S.; Reades, D.W.; Cherry, J.A.; Chambers, D.B.; Case, G.G.; Ibbotson, B.G.

    1983-04-01

    The purpose of this manual is to describe the requisite sampling procedures to provide a basis for the application of uniform high-quality standards to detailed geotechnical, hydrogeological, geochemical and air quality measurements at Canadian uranium tailings disposal sites. The report describes the objective and scope of a sampling program, the preliminary data collection, and the procedures for sampling of tailings solids, surface water and seepage, tailings porewater, and wind-blown dust and radon

  11. Transuranic waste characterization sampling and analysis methods manual. Revision 1

    International Nuclear Information System (INIS)

    Suermann, J.F.

    1996-04-01

    This Methods Manual provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Transuranic Waste Characterization Quality Assurance Program Plan (QAPP) for the Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program) and the WIPP Waste Analysis Plan. This Methods Manual includes all of the testing, sampling, and analytical methodologies accepted by DOE for use in implementing the Program requirements specified in the QAPP and the WIPP Waste Analysis Plan. The procedures in this Methods Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site-specific procedures. With some analytical methods, such as Gas Chromatography/Mass Spectrometry, the Methods Manual procedures may be used directly. With other methods, such as nondestructive characterization, the Methods Manual provides guidance rather than a step-by-step procedure. Sites must meet all of the specified quality control requirements of the applicable procedure. Each DOE site must document the details of the procedures it will use and demonstrate the efficacy of such procedures to the Manager, National TRU Program Waste Characterization, during Waste Characterization and Certification audits

  12. Bottom-up estimation of joint moments during manual lifting using orientation sensors instead of position sensors

    NARCIS (Netherlands)

    Faber, G.S.; Kingma, I.; van Dieen, J.H.

    2010-01-01

    L5/S1, hip and knee moments during manual lifting tasks are, in a laboratory environment, frequently established by bottom-up inverse dynamics, using force plates to measure ground reaction forces (GRFs) and an optoelectronic system to measure segment positions and orientations. For field

  13. Improved orientation sampling for indexing diffraction patterns of polycrystalline materials

    DEFF Research Database (Denmark)

    Larsen, Peter Mahler; Schmidt, Søren

    2017-01-01

    to that of optimally distributing points on a four‐dimensional sphere. In doing so, the number of orientation samples needed to achieve a desired indexing accuracy is significantly reduced. Orientation sets at a range of sizes are generated in this way for all Laue groups and are made available online for easy use.......Orientation mapping is a widely used technique for revealing the microstructure of a polycrystalline sample. The crystalline orientation at each point in the sample is determined by analysis of the diffraction pattern, a process known as pattern indexing. A recent development in pattern indexing...... in the presence of noise, it has very high computational requirements. In this article, the computational burden is reduced by developing a method for nearly optimal sampling of orientations. By using the quaternion representation of orientations, it is shown that the optimal sampling problem is equivalent...

  14. The Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Folley, G.; Pearson, L.; Crosby, C. [Alaska Dept. of Environmental Conservation, Soldotna, AK (United States); DeCola, E.; Robertson, T. [Nuka Research and Planning Group, Seldovia, AK (United States)

    2006-07-01

    A comprehensive water quality sampling program was conducted in response to the oil spill that occurred when the M/V Selendang Ayu ship ran aground near a major fishing port at Unalaska Island, Alaska in December 2004. In particular, the sampling program focused on the threat of spilled oil to the local commercial fisheries resources. Spill scientists were unable to confidently model the movement of oil away from the wreck because of limited oceanographic data. In order to determine which fish species were at risk of oil contamination, a real-time assessment of how and where the oil was moving was needed, because the wreck became a continual source of oil release for several weeks after the initial grounding. The newly developed methods and procedures used to detect whole oil during the sampling program will be presented in the Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual which is currently under development. The purpose of the manual is to provide instructions to spill managers while they try to determine where spilled oil has or has not been encountered. The manual will include a meaningful data set that can be analyzed in real time to assess oil movement and concentration. Sections on oil properties and processes will be included along with scientific water quality sampling methods for whole and dissolved phase oil to assess potential contamination of commercial fishery resources and gear in Alaska waters during an oil spill. The manual will present a general discussion of factors that should be considered when designing a sampling program after a spill. In order to implement Alaska's improved seafood safety measures, the spatial scope of spilled oil must be known. A water quality sampling program can provide state and federal fishery managers and food safety inspectors with important information as they identify at-risk fisheries. 11 refs., 7 figs.

  15. Ligand pose and orientational sampling in molecular docking.

    Directory of Open Access Journals (Sweden)

    Ryan G Coleman

    Full Text Available Molecular docking remains an important tool for structure-based screening to find new ligands and chemical probes. As docking ambitions grow to include new scoring function terms, and to address ever more targets, the reliability and extendability of the orientation sampling, and the throughput of the method, become pressing. Here we explore sampling techniques that eliminate stochastic behavior in DOCK3.6, allowing us to optimize the method for regularly variable sampling of orientations. This also enabled a focused effort to optimize the code for efficiency, with a three-fold increase in the speed of the program. This, in turn, facilitated extensive testing of the method on the 102 targets, 22,805 ligands and 1,411,214 decoys of the Directory of Useful Decoys-Enhanced (DUD-E benchmarking set, at multiple levels of sampling. Encouragingly, we observe that as sampling increases from 50 to 500 to 2000 to 5000 to 20,000 molecular orientations in the binding site (and so from about 1×10(10 to 4×10(10 to 1×10(11 to 2×10(11 to 5×10(11 mean atoms scored per target, since multiple conformations are sampled per orientation, the enrichment of ligands over decoys monotonically increases for most DUD-E targets. Meanwhile, including internal electrostatics in the evaluation ligand conformational energies, and restricting aromatic hydroxyls to low energy rotamers, further improved enrichment values. Several of the strategies used here to improve the efficiency of the code are broadly applicable in the field.

  16. Estimates of Radionuclide Loading to Cochiti Lake from Los Alamos Canyon Using Manual and Automated Sampling

    Energy Technology Data Exchange (ETDEWEB)

    McLean, Christopher T. [Univ. of New Mexico, Albuquerque, NM (United States)

    2000-07-01

    Los Alamos National Laboratory has a long-standing program of sampling storm water runoff inside the Laboratory boundaries. In 1995, the Laboratory started collecting the samples using automated storm water sampling stations; prior to this time the samples were collected manually. The Laboratory has also been periodically collecting sediment samples from Cochiti Lake. This paper presents the data for Pu-238 and Pu-239 bound to the sediments for Los Alamos Canyon storm water runoff and compares the sampling types by mass loading and as a percentage of the sediment deposition to Cochiti Lake. The data for both manual and automated sampling are used to calculate mass loads from Los Alamos Canyon on a yearly basis. The automated samples show mass loading 200- 500 percent greater for Pu-238 and 300-700 percent greater for Pu-239 than the manual samples. Using the mean manual flow volume for mass loading calculations, the automated samples are over 900 percent greater for Pu-238 and over 1800 percent greater for Pu-239. Evaluating the Pu-238 and Pu-239 activities as a percentage of deposition to Cochiti Lake indicates that the automated samples are 700-1300 percent greater for Pu- 238 and 200-500 percent greater for Pu-239. The variance was calculated by two methods. The first method calculates the variance for each sample event. The second method calculates the variances by the total volume of water discharged in Los Alamos Canyon for the year.

  17. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 2, Radiation Monitoring and Sampling

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The FRMAC Monitoring and Sampling Manual, Volume 2 provides standard operating procedures (SOPs) for field radiation monitoring and sample collection activities that are performed by the Monitoring group during a FRMAC response to a radiological emergency.

  18. Radiology Aide. Instructor Key [and] Student Manual.

    Science.gov (United States)

    Hartwein, Jon; Dunham, John

    This manual can be used independently by students in secondary health occupations programs or by persons receiving on-the-job training in a radiology department. The manual includes an instructor's key that provides answers to the activity sheets and unit evaluations. The manual consists of the following five units: (1) orientation to radiology;…

  19. Development of object oriented program `SONSHO` for strength evaluation. Manual of Version 4.0 program

    Energy Technology Data Exchange (ETDEWEB)

    Hosogai, Hiromi [Joyo Industries Co. Ltd., Tokai, Ibaraki (Japan); Kasahara, Naoto

    1998-07-01

    Object Oriented Program `SONSHO` predicts creep fatigue damage factors based on Elevated Temperature Structural Design Guide for `Monju` and other various procedures from stress classification data obtained from structural analysis results. From view point of program implementation, it is required that external programs interface and frequent revise from update of material and creep fatigue evaluation methods. Object oriented approach was continuously introduced to improve these aspects of the program. Version 4.0 has the following new functions. (1) Material strength library was implemented as an independent program module based on Microsoft Active X control and 32bitDLL technologies, which can be accessed by general Windows programs. (2) Self instruction system `Wizard` enables manual less operation. (3) Microsoft common object model (COM) was adopted for program interface, and this program can communicate with Excel sheet data on memory. Sonsho Ver.4.0 can work on Windows 95 or Windows NT4.0. Microsoft Visual Basic 5.0 (Enterprose Edition) and Microsoft FORTRAN Power Station 4.0 were adopted for program. (author)

  20. Dakota, a multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis version 6.0 theory manual

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Brian M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ebeida, Mohamed Salah [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Eldred, Michael S [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jakeman, John Davis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Swiler, Laura Painton [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stephens, John Adam [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vigil, Dena M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wildey, Timothy Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bohnhoff, William J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hu, Kenneth T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dalbey, Keith R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bauman, Lara E [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hough, Patricia Diane [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-05-01

    The Dakota (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a exible and extensible interface between simulation codes and iterative analysis methods. Dakota contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quanti cation with sampling, reliability, and stochastic expansion methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the Dakota toolkit provides a exible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a theoretical manual for selected algorithms implemented within the Dakota software. It is not intended as a comprehensive theoretical treatment, since a number of existing texts cover general optimization theory, statistical analysis, and other introductory topics. Rather, this manual is intended to summarize a set of Dakota-related research publications in the areas of surrogate-based optimization, uncertainty quanti cation, and optimization under uncertainty that provide the foundation for many of Dakota's iterative analysis capabilities.

  1. Molecular orientation of individual LCP particles in injection-moulded PPS/LCP blends

    Directory of Open Access Journals (Sweden)

    Kestenbach H.-J.

    2003-01-01

    Full Text Available Polarized light microscopy was used to investigate the presence of preferred molecular orientation in the LCP phase of PPS/LCP blends after injection moulding. Normal birefringence effects appeared to be complicated by artifacts due to sample preparation and by the complex nature of polarized light transmission through a multicomponent sample. It was found, however, that, during low-temperature cutting of optically transparent thin sections on a standard microtome, individual LCP particles could be separated from the PPS matrix, and their birefringence analyzed separately. Preferred orientation was detected only in LCP fibrils which dominated in skin regions, but not in droplet-shaped particles which had formed in core regions. Quantitative measurements indicated that the molecular orientation of the fibrils increased linearly with their length-to-diameter aspect ratios which ranged from 15 to 50. Even for the highest aspect ratios, however, the degree of orientation was always less than that which could easily be introduced into pure LCP thin-film samples by manual shearing.

  2. Field manual for geohydrological sampling as applied to the radioactive waste disposal program

    International Nuclear Information System (INIS)

    Levin, M.

    1983-08-01

    This report serves as a manual for geohydrological sampling as practised by NUCOR's Geology Department. It discusses systematically all aspects concerned with sampling and stresses those where negligence has caused complications in the past. Accurate, neat and systematic procedures are emphasised. The report is intended as a reference work for the field technician. Analytical data on water samples provide an indication of the geohydrological processes taking place during the interaction between groundwater and the enclosing aquifers. It is possible to identify water bodies, using some of a multitude of parameters such as major ions, trace elements and isotopes which may give clues as to the origin, directions of flow and age of groundwater bodies. The South African Radioactive Waste Project also requires this information for determining the direction of migration of the radionuclides in the environment in the event of a spillage. The sampling procedures required for water, and in particular groundwater, must be applied in such a manner that the natural variation of dissolved species is not disturbed to any significant degree. With this in mind, the operator has to exercise meticulous care during initial preparation, collection, storing, preserving and handling of the water samples. This report is a field manual and describes the procedures adopted for the Radwaste Project geohydrological investigations in the Northwest Cape

  3. The Orientation of Gastric Biopsy Samples Improves the Inter-observer Agreement of the OLGA Staging System.

    Science.gov (United States)

    Cotruta, Bogdan; Gheorghe, Cristian; Iacob, Razvan; Dumbrava, Mona; Radu, Cristina; Bancila, Ion; Becheanu, Gabriel

    2017-12-01

    Evaluation of severity and extension of gastric atrophy and intestinal metaplasia is recommended to identify subjects with a high risk for gastric cancer. The inter-observer agreement for the assessment of gastric atrophy is reported to be low. The aim of the study was to evaluate the inter-observer agreement for the assessment of severity and extension of gastric atrophy using oriented and unoriented gastric biopsy samples. Furthermore, the quality of biopsy specimens in oriented and unoriented samples was analyzed. A total of 35 subjects with dyspeptic symptoms addressed for gastrointestinal endoscopy that agreed to enter the study were prospectively enrolled. The OLGA/OLGIM gastric biopsies protocol was used. From each subject two sets of biopsies were obtained (four from the antrum, two oriented and two unoriented, two from the gastric incisure, one oriented and one unoriented, four from the gastric body, two oriented and two unoriented). The orientation of the biopsy samples was completed using nitrocellulose filters (Endokit®, BioOptica, Milan, Italy). The samples were blindly examined by two experienced pathologists. Inter-observer agreement was evaluated using kappa statistic for inter-rater agreement. The quality of histopathology specimens taking into account the identification of lamina propria was analyzed in oriented vs. unoriented samples. The samples with detectable lamina propria mucosae were defined as good quality specimens. Categorical data was analyzed using chi-square test and a two-sided p value <0.05 was considered statistically significant. A total of 350 biopsy samples were analyzed (175 oriented / 175 unoriented). The kappa index values for oriented/unoriented OLGA 0/I/II/III and IV stages have been 0.62/0.13, 0.70/0.20, 0.61/0.06, 0.62/0.46, and 0.77/0.50, respectively. For OLGIM 0/I/II/III stages the kappa index values for oriented/unoriented samples were 0.83/0.83, 0.88/0.89, 0.70/0.88 and 0.83/1, respectively. No case of OLGIM IV

  4. Radar and ARPA manual

    CERN Document Server

    Bole, A G

    2013-01-01

    Radar and ARPA Manual focuses on the theoretical and practical aspects of electronic navigation. The manual first discusses basic radar principles, including principles of range and bearing measurements and picture orientation and presentation. The text then looks at the operational principles of radar systems. Function of units; aerial, receiver, and display principles; transmitter principles; and sitting of units on board ships are discussed. The book also describes target detection, Automatic Radar Plotting Aids (ARPA), and operational controls of radar systems, and then discusses radar plo

  5. DAKOTA, a multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis:version 4.0 reference manual

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Joshua D. (Sandai National Labs, Livermore, CA); Eldred, Michael Scott; Martinez-Canales, Monica L. (Sandai National Labs, Livermore, CA); Watson, Jean-Paul; Kolda, Tamara Gibson (Sandai National Labs, Livermore, CA); Adams, Brian M.; Swiler, Laura Painton; Williams, Pamela J. (Sandai National Labs, Livermore, CA); Hough, Patricia Diane (Sandai National Labs, Livermore, CA); Gay, David M.; Dunlavy, Daniel M.; Eddy, John P.; Hart, William Eugene; Guinta, Anthony A.; Brown, Shannon L.

    2006-10-01

    The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic finite element methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a reference manual for the commands specification for the DAKOTA software, providing input overviews, option descriptions, and example specifications.

  6. Military construction program economic analysis manual: Sample economic analyses: Hazardous Waste Remedial Actions Program

    International Nuclear Information System (INIS)

    1987-12-01

    This manual enables the US Air Force to comprehensively and systematically analyze alternative approaches to meeting its military construction requirements. The manual includes step-by-step procedures for completing economic analyses for military construction projects, beginning with determining if an analysis is necessary. Instructions and a checklist of the tasks involved for each step are provided; and examples of calculations and illustrations of completed forms are included. The manual explains the major tasks of an economic analysis, including identifying the problem, selecting realistic alternatives for solving it, formulating appropriate assumptions, determining the costs and benefits of the alternatives, comparing the alternatives, testing the sensitivity of major uncertainties, and ranking the alternatives. Appendixes are included that contain data, indexes, and worksheets to aid in performing the economic analyses. For reference, Volume 2 contains sample economic analyses that illustrate how each form is filled out and that include a complete example of the documentation required

  7. Mapping molecular orientational distributions for biological sample in 3D (Conference Presentation)

    Science.gov (United States)

    HE, Wei; Ferrand, Patrick; Richter, Benjamin; Bastmeyer, Martin; Brasselet, Sophie

    2016-04-01

    Measuring molecular orientation properties is very appealing for scientists in molecular and cell biology, as well as biomedical research. Orientational organization at the molecular scale is indeed an important brick to cells and tissues morphology, mechanics, functions and pathologies. Recent work has shown that polarized fluorescence imaging, based on excitation polarization tuning in the sample plane, is able to probe molecular orientational order in biological samples; however this applies only to information in 2D, projected in the sample plane. To surpass this limitation, we extended this approach to excitation polarization tuning in 3D. The principle is based on the decomposition of any arbitrary 3D linear excitation in a polarization along the longitudinal z-axis, and a polarization in the transverse xy-sample plane. We designed an interferometer with one arm generating radial polarization light (thus producing longitudinal polarization under high numerical aperture focusing), the other arm controlling a linear polarization in the transverse plane. The amplitude ratio between the two arms can vary so as to get any linear polarized excitation in 3D at the focus of a high NA objective. This technique has been characterized by polarimetry imaging at the back focal plane of the focusing objective, and modeled theoretically. 3D polarized fluorescence microscopy is demonstrated on actin stress fibers in non-flat cells suspended on synthetic polymer structures forming supporting pillars, for which heterogeneous actin orientational order could be identified. This technique shows a great potential in structural investigations in 3D biological systems, such as cell spheroids and tissues.

  8. Highly oriented Bi-system bulk sample prepared by a decomposition-crystallization process

    International Nuclear Information System (INIS)

    Xi Zhengping; Zhou Lian; Ji Chunlin

    1992-01-01

    A decomposition-crystallization method, preparing highly oriented Bi-system bulk sample is reported. The effects of processing parameter, decomposition temperature, cooling rate and post-treatment condition on texture and superconductivity are investigated. The method has successfully prepared highly textured Bi-system bulk samples. High temperature annealing does not destroy the growing texture, but the cooling rate has some effect on texture and superconductivity. Annealing in N 2 /O 2 atmosphere can improve superconductivity of the textured sample. The study on the superconductivity of the Bi(Pb)-Sr-Ca-Cu-O bulk material has been reported in numerous papers. The research on J c concentrates on the tape containing the 2223 phase, with very few studies on the J c of bulk sample. The reason for the lack of studies is that the change of superconducting phases at high temperatures has not been known. The authors have reported that the 2212 phase incongruently melted at about 875 degrees C and proceeded to orient the c-axis perpendicular to the surface in the process of crystallization of the 2212 phase. Based on that result, a decomposition-crystallization method was proposed to prepare highly oriented Bi-system bulk sample. In this paper, the process is described in detail and the effects of processing parameters on texture and superconductivity are reported

  9. NMR of bicelles: orientation and mosaic spread of the liquid-crystal director under sample rotation

    International Nuclear Information System (INIS)

    Zandomeneghi, Giorgia; Tomaselli, Marco; Williamson, Philip T.F.; Meier, Beat H.

    2003-01-01

    Model-membrane systems composed of liquid-crystalline bicellar phases can be uniaxially oriented with respect to a magnetic field, thereby facilitating structural and dynamics studies of membrane-associated proteins. Here we quantitatively characterize a method that allows the manipulation of the direction of this uniaxial orientation. Bicelles formed from DMPC/DHPC are examined by 31 P NMR under variable-angle sample-spinning (VAS) conditions, confirming that the orientation of the liquid-crystalline director can be influenced by sample spinning. The director is perpendicular to the rotation axis when Θ (the angle between the sample-spinning axis and the magnetic field direction) is smaller than the magic angle, and is parallel to the rotation axis when Θ is larger than the magic angle. The new 31 P NMR VAS data presented are considerably more sensitive to the orientation of the bicelle than earlier 2 H studies and the analysis of the sideband pattern allows the determination of the orientation of the liquid-crystal director and its variation over the sample, i.e., the mosaic spread. Under VAS, the mosaic spread is small if Θ deviates significantly from the magic angle but becomes very large at the magic angle

  10. Nuclear electronics laboratory manual

    International Nuclear Information System (INIS)

    1984-05-01

    The Nuclear Electronics Laboratory Manual is a joint product of several electronics experts who have been associated with IAEA activity in this field for many years. The manual does not include experiments of a basic nature, such as characteristics of different active electronics components. It starts by introducing small electronics blocks, employing one or more active components. The most demanding exercises instruct a student in the design and construction of complete circuits, as used in commercial nuclear instruments. It is expected that a student who completes all the experiments in the manual should be in a position to design nuclear electronics units and also to understand the functions of advanced commercial instruments which need to be repaired or maintained. The future tasks of nuclear electronics engineers will be increasingly oriented towards designing and building the interfaces between a nuclear experiment and a computer. The manual pays tribute to this development by introducing a number of experiments which illustrate the principles and the technology of interfacing

  11. Validating the Orientations to Happiness Scale in a Chinese Sample of University Students

    Science.gov (United States)

    Chen, Guo-Hai

    2010-01-01

    This paper examined the reliability and validity of the Orientation to Happiness Scale with a sample of Chinese correspondents. Chinese translation of the Orientation to Happiness Scale, Satisfaction with Life Scale, Temporal Satisfaction with Life Scale, and General Life Satisfaction Scale, were administered to 671 Chinese university students…

  12. Special study for the manual transfer of process samples from CPP [Chemical Processing Plant] 601 to RAL [Remote Analytical Laboratory

    International Nuclear Information System (INIS)

    Marts, D.J.

    1987-05-01

    A study of alternate methods to manually transport radioactive samples from their glove boxes to the Remote Analytical Laboratory (RAL) was conducted at the Idaho National Engineering Laboratory. The study was performed to mitigate the effects of a potential loss of sampling capabilities that could take place if a malfunction in the Pneumatic Transfer System (PTS) occurred. Samples are required to be taken from the cell glove boxes and analyzed at the RAL regardless of the operational status of the PTS. This paper documents the conclusions of the study and how a decision was reached that determined the best handling scenarios for manually transporting 15 mL vials of liquid process samples from the K, W, U, WG, or WH cell glove boxes in the Chemical Processing Plant (CPP) 601 to the RAL. This study of methods to manually remove the samples from the glove boxes, package them for safe shipment, transport them by the safest route, receive them at the RAL, and safely unload them was conducted by EG and G Idaho, Inc., for Westinghouse Idaho Nuclear Company as part of the Glove Box Sampling and Transfer System Project for the Fuel Processing Facilities Upgrade, Task 10, Subtask 2. The study focused on the safest and most reliable scenarios that could be implemented using existing equipment. Hardware modifications and new hardware proposals were identified, and their impact on the handling scenario has been evaluated. A conclusion was reached that by utilizing the existing facility hardware, these samples can be safely transported manually from the sample stations in CPP 601 to the RAL, and that additional hardware could facilitate the transportation process even further

  13. Dakota, a multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis:version 4.0 developers manual.

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Joshua D. (Sandia National lababoratory, Livermore, CA); Eldred, Michael Scott; Martinez-Canales, Monica L. (Sandia National lababoratory, Livermore, CA); Watson, Jean-Paul; Kolda, Tamara Gibson (Sandia National lababoratory, Livermore, CA); Giunta, Anthony Andrew; Adams, Brian M.; Swiler, Laura Painton; Williams, Pamela J. (Sandia National lababoratory, Livermore, CA); Hough, Patricia Diane (Sandia National lababoratory, Livermore, CA); Gay, David M.; Dunlavy, Daniel M.; Eddy, John P.; Hart, William Eugene; Brown, Shannon L.

    2006-10-01

    The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic finite element methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a developers manual for the DAKOTA software and describes the DAKOTA class hierarchies and their interrelationships. It derives directly from annotation of the actual source code and provides detailed class documentation, including all member functions and attributes.

  14. DAKOTA : a multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis. Version 5.0, developers manual.

    Energy Technology Data Exchange (ETDEWEB)

    Eldred, Michael Scott; Dalbey, Keith R.; Bohnhoff, William J.; Adams, Brian M.; Swiler, Laura Painton; Hough, Patricia Diane (Sandia National Laboratories, Livermore, CA); Gay, David M.; Eddy, John P.; Haskell, Karen H.

    2010-05-01

    The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic finite element methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a developers manual for the DAKOTA software and describes the DAKOTA class hierarchies and their interrelationships. It derives directly from annotation of the actual source code and provides detailed class documentation, including all member functions and attributes.

  15. DAKOTA, a multilevel parellel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis:version 4.0 uers's manual.

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Joshua D. (Sandai National Labs, Livermore, CA); Eldred, Michael Scott; Martinez-Canales, Monica L. (Sandai National Labs, Livermore, CA); Watson, Jean-Paul; Kolda, Tamara Gibson (Sandai National Labs, Livermore, CA); Giunta, Anthony Andrew; Adams, Brian M.; Swiler, Laura Painton; Williams, Pamela J. (Sandai National Labs, Livermore, CA); Hough, Patricia Diane (Sandai National Labs, Livermore, CA); Gay, David M.; Dunlavy, Daniel M.; Eddy, John P.; Hart, William Eugene; Brown, Shannon L.

    2006-10-01

    The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic finite element methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a user's manual for the DAKOTA software and provides capability overviews and procedures for software execution, as well as a variety of example studies.

  16. DAKOTA : a multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis. Version 5.0, user's manual.

    Energy Technology Data Exchange (ETDEWEB)

    Eldred, Michael Scott; Dalbey, Keith R.; Bohnhoff, William J.; Adams, Brian M.; Swiler, Laura Painton; Hough, Patricia Diane (Sandia National Laboratories, Livermore, CA); Gay, David M.; Eddy, John P.; Haskell, Karen H.

    2010-05-01

    The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic finite element methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a user's manual for the DAKOTA software and provides capability overviews and procedures for software execution, as well as a variety of example studies.

  17. Resource Manual for Functional Vision Evaluation. Technical Assistance Bulletin.

    Science.gov (United States)

    Texas Education Agency, Austin. Div. of Special Education.

    The manual was intended to help school personnel (either an educator of the visually handicapped and/or a certified orientation and mobility instructor) evaluate the functional use of residual vision. The manual is organized in three major sections, which cover the following: (1) the general areas addressed in functional vision evaluation (such as…

  18. Plasma cortisol and noradrenalin concentrations in pigs: automated sampling of freely moving pigs housed in PigTurn versus manually sampled and restrained pigs

    Science.gov (United States)

    Minimizing the effects of restraint and human interaction on the endocrine physiology of animals is essential for collection of accurate physiological measurements. Our objective was to compare stress-induced cortisol (CORT) and noradrenalin (NorA) responses in automated versus manual blood sampling...

  19. The Northern States Power Company welding manual advisor

    International Nuclear Information System (INIS)

    Lu, Yi; Wood, R.M.

    1993-01-01

    The Welding Manual Advisor (WMA) is an object oriented expert system designed to assist Northern States Power (NSP) personnel in implementing the company's Welding Manual. The expert system captures the knowledge of welding experts, addresses important issues in welding activities and automates the use of the Welding Manual. It is estimated that use of the WMA will save $81,000 over the next six years at NSP, because of the reduction of labor and errors in the use of the Welding Manual, and facilitation of training of NSP personnel. The important features of the WMA include the accuracy and consistency in determining welding procedure and requirements, update capability, user friendly interface, on-line help function, back-up capability, and well-documented manuals

  20. Procedure manual for the estimation of average indoor radon-daughter concentrations using the radon grab-sampling method

    International Nuclear Information System (INIS)

    George, J.L.

    1986-04-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center to provide standardization, calibration, comparability, verification of data, quality assurance, and cost-effectiveness for the measurement requirements of DOE remedial action programs. One of the remedial-action measurement needs is the estimation of average indoor radon-daughter concentration. One method for accomplishing such estimations in support of DOE remedial action programs is the radon grab-sampling method. This manual describes procedures for radon grab sampling, with the application specifically directed to the estimation of average indoor radon-daughter concentration (RDC) in highly ventilated structures. This particular application of the measurement method is for cases where RDC estimates derived from long-term integrated measurements under occupied conditions are below the standard and where the structure being evaluated is considered to be highly ventilated. The radon grab-sampling method requires that sampling be conducted under standard maximized conditions. Briefly, the procedure for radon grab sampling involves the following steps: selection of sampling and counting equipment; sample acquisition and processing, including data reduction; calibration of equipment, including provisions to correct for pressure effects when sampling at various elevations; and incorporation of quality-control and assurance measures. This manual describes each of the above steps in detail and presents an example of a step-by-step radon grab-sampling procedure using a scintillation cell

  1. Manual vs. computer-assisted sperm analysis: can CASA replace manual assessment of human semen in clinical practice?

    Science.gov (United States)

    Talarczyk-Desole, Joanna; Berger, Anna; Taszarek-Hauke, Grażyna; Hauke, Jan; Pawelczyk, Leszek; Jedrzejczak, Piotr

    2017-01-01

    The aim of the study was to check the quality of computer-assisted sperm analysis (CASA) system in comparison to the reference manual method as well as standardization of the computer-assisted semen assessment. The study was conducted between January and June 2015 at the Andrology Laboratory of the Division of Infertility and Reproductive Endocrinology, Poznań University of Medical Sciences, Poland. The study group consisted of 230 men who gave sperm samples for the first time in our center as part of an infertility investigation. The samples underwent manual and computer-assisted assessment of concentration, motility and morphology. A total of 184 samples were examined twice: manually, according to the 2010 WHO recommendations, and with CASA, using the program set-tings provided by the manufacturer. Additionally, 46 samples underwent two manual analyses and two computer-assisted analyses. The p-value of p CASA and manually. In the group of patients where all analyses with each method were performed twice on the same sample we found no significant differences between both assessments of the same probe, neither in the samples analyzed manually nor with CASA, although standard deviation was higher in the CASA group. Our results suggest that computer-assisted sperm analysis requires further improvement for a wider application in clinical practice.

  2. DAKOTA : a multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis. Version 5.0, user's reference manual.

    Energy Technology Data Exchange (ETDEWEB)

    Eldred, Michael Scott; Dalbey, Keith R.; Bohnhoff, William J.; Adams, Brian M.; Swiler, Laura Painton; Hough, Patricia Diane (Sandia National Laboratories, Livermore, CA); Gay, David M.; Eddy, John P.; Haskell, Karen H.

    2010-05-01

    The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic finite element methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a reference manual for the commands specification for the DAKOTA software, providing input overviews, option descriptions, and example specifications.

  3. Visuo-manual tracking: does intermittent control with aperiodic sampling explain linear power and non-linear remnant without sensorimotor noise?

    Science.gov (United States)

    Gollee, Henrik; Gawthrop, Peter J; Lakie, Martin; Loram, Ian D

    2017-11-01

    A human controlling an external system is described most easily and conventionally as linearly and continuously translating sensory input to motor output, with the inevitable output remnant, non-linearly related to the input, attributed to sensorimotor noise. Recent experiments show sustained manual tracking involves repeated refractoriness (insensitivity to sensory information for a certain duration), with the temporary 200-500 ms periods of irresponsiveness to sensory input making the control process intrinsically non-linear. This evidence calls for re-examination of the extent to which random sensorimotor noise is required to explain the non-linear remnant. This investigation of manual tracking shows how the full motor output (linear component and remnant) can be explained mechanistically by aperiodic sampling triggered by prediction error thresholds. Whereas broadband physiological noise is general to all processes, aperiodic sampling is associated with sensorimotor decision making within specific frontal, striatal and parietal networks; we conclude that manual tracking utilises such slow serial decision making pathways up to several times per second. The human operator is described adequately by linear translation of sensory input to motor output. Motor output also always includes a non-linear remnant resulting from random sensorimotor noise from multiple sources, and non-linear input transformations, for example thresholds or refractory periods. Recent evidence showed that manual tracking incurs substantial, serial, refractoriness (insensitivity to sensory information of 350 and 550 ms for 1st and 2nd order systems respectively). Our two questions are: (i) What are the comparative merits of explaining the non-linear remnant using noise or non-linear transformations? (ii) Can non-linear transformations represent serial motor decision making within the sensorimotor feedback loop intrinsic to tracking? Twelve participants (instructed to act in three prescribed

  4. Sexual Orientation and Borderline Personality Disorder Features in a Community Sample of Adolescents.

    Science.gov (United States)

    Reuter, Tyson R; Sharp, Carla; Kalpakci, Allison H; Choi, Hye J; Temple, Jeff R

    2016-10-01

    Empirical literature demonstrates that sexual minorities are at an increased risk of developing psychopathology, including borderline personality disorder (BPD). The specific link between sexual orientation and BPD has received significantly less attention in youth, and it remains unclear what drives this relation. Given that there are higher rates of psychopathology in both sexual minorities and individuals with BPD, the present study aimed to determine if sexual orientation uniquely contributes to borderline personality pathology, controlling for other psychopathology. An ethnically diverse sample of 835 adolescents completed self-report measures of borderline features, depression, anxiety, and sexual orientation. Sexual minorities scored higher on borderline features compared to heterosexual adolescents. When controlling for depression and anxiety, sexual orientation remained significantly associated with borderline features. The relation between sexual orientation and BPD cannot fully be explained by other psychopathology. Future research is necessary to understand potential mechanisms underlying this relation.

  5. Comparison of Czech, Slovak and Swiss Product Innovation Oriented Firms’ Communication in Social Media

    Directory of Open Access Journals (Sweden)

    Vít Chlebovský

    2015-01-01

    Full Text Available Objective of the research described in this article is to analyze and compare the use of social media communication channels in Czech, Slovak and Swiss product innovation oriented companies, where Swiss set of the companies is used as a benchmark. Primary research was made through manual activity scanning of the selected companies within social media. European company database Amadeus provided by Bureau van Dijk was used for the company selection in all three countries under the same search criteria. There were made two research sets of the companies in each country. One set covers top turnover product innovation oriented companies, second set avoided product innovation orientation search criteria and covers top companies by turnover in the respective country. Each particular sample set covered 74 to 100 companies.Activities of the selected companies on Facebook, YouTube, Twitter, Google+ and LinkedIn were manually scanned and particular metrics were scaled. Microsoft Excel was used for storing, statistical processing and graphic outputs of the research. Evaluated results show significant gaps in use of social media communication tools in Czech and Slovak companies comparing to Swiss benchmark. It has been also confirmed that social media communication activity in product innovation oriented companies is equal to other companies. The hypotheses were statistically tested and results confirmed.

  6. Sexual orientation and treatment-seeking for depression in a multilingual worldwide sample.

    Science.gov (United States)

    Rutter, Tara M; Flentje, Annesa; Dilley, James W; Barakat, Suzanne; Liu, Nancy H; Gross, Margaret S; Muñoz, Ricardo F; Leykin, Yan

    2016-12-01

    Prior research has found higher rates of mental health problems among sexual minority individuals. We examine treatment-seeking for depression, as well as its relationship with sexual orientation, in a large, multilingual, international sample. Participants in an automated, quintilingual internet-based depression screening tool were screened for depression, and completed several background measures, including sexual orientation (with an option to decline to state) and past and current depression treatment seeking. 3695 participants screened positive for current or past depression and responded to the sexual orientation question. Those who declined to state their sexual orientation were far less likely to seek any treatment than individuals endorsing any orientation; they were especially unlikely to seek psychotherapy. Individuals identifying as bisexual sought both psychotherapy and alternative treatments at a higher rate than other groups. An interaction was observed between sexual orientation and gender, such that lesbian women were especially likely to have used psychotherapy. Other variables that emerged as significant predictors of treatment-seeking for depression included age and participant's language. Limitations include possible misinterpretation of translated terms due to regional differences, and possible limits to generalizability due to this study being conducted on the internet. Our results suggest that individuals who decline to state their sexual orientation may be more likely to forgo effective treatments for depression. Further studies of depression service utilization should focus on developing treatment modalities that could better engage sexual minority individuals, especially those who are reluctant to disclose their orientation. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Orientation Strategies for Aerial Oblique Images

    Science.gov (United States)

    Wiedemann, A.; Moré, J.

    2012-07-01

    Oblique aerial images become more and more distributed to fill the gap between vertical aerial images and mobile mapping systems. Different systems are on the market. For some applications, like texture mapping, precise orientation data are required. One point is the stable interior orientation, which can be achieved by stable camera systems, the other a precise exterior orientation. A sufficient exterior orientation can be achieved by a large effort in direct sensor orientation, whereas minor errors in the angles have a larger effect than in vertical imagery. The more appropriate approach is by determine the precise orientation parameters by photogrammetric methods using an adapted aerial triangulation. Due to the different points of view towards the object the traditional aerotriangulation matching tools fail, as they produce a bunch of blunders and require a lot of manual work to achieve a sufficient solution. In this paper some approaches are discussed and results are presented for the most promising approaches. We describe a single step approach with an aerotriangulation using all available images; a two step approach with an aerotriangulation only of the vertical images plus a mathematical transformation of the oblique images using the oblique cameras excentricity; and finally the extended functional model for a bundle block adjustment considering the mechanical connection between vertical and oblique images. Beside accuracy also other aspects like efficiency and required manual work have to be considered.

  8. Water-quality assessment of south-central Texas : comparison of water quality in surface-water samples collected manually and by automated samplers

    Science.gov (United States)

    Ging, Patricia B.

    1999-01-01

    Surface-water sampling protocols of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program specify samples for most properties and constituents to be collected manually in equal-width increments across a stream channel and composited for analysis. Single-point sampling with an automated sampler (autosampler) during storms was proposed in the upper part of the South-Central Texas NAWQA study unit, raising the question of whether property and constituent concentrations from automatically collected samples differ significantly from those in samples collected manually. Statistical (Wilcoxon signed-rank test) analyses of 3 to 16 paired concentrations for each of 26 properties and constituents from water samples collected using both methods at eight sites in the upper part of the study unit indicated that there were no significant differences in concentrations for dissolved constituents, other than calcium and organic carbon.

  9. Comparison of semiautomated bird song recognition with manual detection of recorded bird song samples

    OpenAIRE

    Lisa A. Venier; Marc J. Mazerolle; Anna Rodgers; Ken A. McIlwrick; Stephen Holmes; Dean Thompson

    2017-01-01

    Automated recording units are increasingly being used to sample wildlife populations. These devices can produce large amounts of data that are difficult to process manually. However, the information in the recordings can be summarized with semiautomated sound recognition software. Our objective was to assess the utility of the semiautomated bird song recognizers to produce data useful for conservation and sustainable forest management applications. We compared detection data generated from ex...

  10. Ethics in Counsellor Education: A Sample Orientation Manual

    Science.gov (United States)

    Braun, Ruth Bergen

    2009-01-01

    This project draws attention to ethics in counsellor education, showing that ethics is critical to the formation of new counsellors, not simply an add-on component in counsellor training. This project demonstrates that beginning counsellors, before they commence employment, must have a strong ethical foundation. It examines both formal counsellor…

  11. The relationship between sexual orientation and depression in a national population sample.

    Science.gov (United States)

    Scott, Roger L; Lasiuk, Gerri; Norris, Colleen

    2016-12-01

    The aim of this study was to examine the relationship between sexual orientation and depression in a nationally representative population to determine if sexual minorities report higher levels of depression than the remainder of the population. Depression is a highly prevalent and disabling chronic disorder worldwide. Prior research utilizing national population samples have reported that members of sexual minorities are at higher risk for depression when compared to heterosexual people. More recent studies have revealed differences in depression risk based on sexual orientation, sexual activity and sex. There have been significant shifts in societal attitudes towards sexual minorities in recent decades. Continuing research into predictors for reporting depression amongst sexual minorities is needed. National Health and Nutrition Examination Survey cycles 2005-2012 were used to identify sexual minority status based on declared sexual orientation and presence of same-sex sexual activity. Complex samples logistic and multivariate regression models were used to predict depression adjusted for sexual orientation, sexual activity, age, sex, marital status, education, income, race/ethnicity, employment and health status. Sexual orientation was not a significant independent predictor of depressive symptoms overall. Gay men reported lower levels of depressive symptoms than heterosexual men. In the sex stratified analyses, men who reported having sex with men were five times more likely to report depressive symptomatology compared to men who reported opposite sex partners (2005-2008 adjusted odds ratios: 5·00; 95% confidence interval: 1·44-17·38; 2009-2012 adjusted odds ratios: 5·10; 95% confidence interval: 1·33-19·54) after controlling for sexual orientation. Results of our analyses indicate that homosexually experienced heterosexual men appear to be at highest risk for depression. Furthermore, reported physical health status was a significant independent predictor

  12. A low-temperature sample orienting device for single crystal spectroscopy at the SNS

    Energy Technology Data Exchange (ETDEWEB)

    Sherline, T E; Solomon, L; Roberts, C K II; Bruce, D; Gaulin, B; Granroth, G E, E-mail: sherlinete@ornl.gov

    2010-11-01

    A low temperature sample orientation device providing three axes of rotation has been successfully built and is in testing for use on several spectrometers at the spallation neutron source (SNS). Sample rotation about the vertical ({omega}) axis of nearly 360 deg. and out of plane tilts ({phi} and v) of from -3.4 deg. to 4.4 deg. and from -2.8 deg. to 3.5 deg., respectively, are possible. An off-the-shelf closed cycle refrigerator (CCR) is mounted on a room temperature sealed rotary flange providing {omega} rotations of the sample. Out-of-plane tilts are made possible by piezoelectric actuated angular positioning devices mounted on the low temperature head of the CCR. Novel encoding devices based on magnetoresistive sensors have been developed to measure the tilt stage angles. This combination facilitates single crystal investigations from room temperature to 3.1 K. Commissioning experiments of the rotating CCR for both powder and single crystal samples have been performed on the ARCS spectrometer at the SNS. For the powder sample this device was used to continuously rotate the sample and thus average out any partial orientation of the powder. The powder rings observed in S(Q) are presented. For the single crystal sample, the rotation was used to probe different regions of momentum transfer (Q-space). Laue patterns obtained from a single crystal sample at two rotation angles are presented.

  13. Sexual health behaviors and sexual orientation in a U.S. national sample of college students.

    Science.gov (United States)

    Oswalt, Sara B; Wyatt, Tammy J

    2013-11-01

    Many studies have examined differences in sexual behavior based on sexual orientation with results often indicating that those with same-sex partners engage in higher risk sexual behavior than people with opposite sex partners. However, few of these studies were large, national sample studies that also include those identifying as unsure. To address that gap, this study examined the relationship of sexual orientation and sexual health outcomes in a national sample of U.S. college students. The Fall 2009 American College Health Association-National College Health Assessment was used to examine sexual health related responses from heterosexual, gay, lesbian, bisexual, and unsure students (N = 25,553). Responses related to sexual behavior, safer sex behaviors, prevention and screening behaviors, and diagnosis of sexual health related conditions were examined. The findings indicated that sexual orientation was significantly associated with engaging in sexual behavior in the last 30 days. Sexual orientation was also significantly associated with the number of sexual partners in the previous 12 months, with unsure men having significantly more partners than gay, bisexual and heterosexual men and heterosexual men having significantly less partners than gay, bisexual and unsure men. Bisexual women had significantly more partners than females reporting other sexual orientations. Results examining the associations between sexual orientation and safer sex, prevention behaviors, and screening behaviors were mixed. Implications for practice, including specific programmatic ideas, were discussed.

  14. Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples.

    Science.gov (United States)

    Choi, Qute; Kim, Hyun Jin; Kim, Jong Wan; Kwon, Gye Cheol; Koo, Sun Hoe

    2018-01-04

    The process of plate streaking has been automated to improve routine workflow of clinical microbiology laboratories. Although there were many evaluation reports about the inoculation of various body fluid samples, few evaluations have been reported for blood. In this study, we evaluated the performance of automated inoculating system, Previ Isola for various routine clinical samples including blood. Blood culture, body fluid, and urine samples were collected. All samples were inoculated on both sheep blood agar plate (BAP) and MacConkey agar plate (MCK) using Previ Isola and manual method. We compared two methods in aspect of quality and quantity of cultures, and sample processing time. To ensure objective colony counting, an enumeration reading reference was made through a preliminary experiment. A total of 377 nonduplicate samples (102 blood culture, 203 urine, 72 body fluid) were collected and inoculated. The concordance rate of quality was 100%, 97.0%, and 98.6% in blood, urine, and other body fluids, respectively. In quantitative aspect, it was 98.0%, 97.0%, and 95.8%, respectively. The Previ Isola took a little longer to inoculate the specimen than manual method, but the hands-on time decreased dramatically. The shortened hands-on time using Previ Isola was about 6 minutes per 10 samples. We demonstrated that the Previ Isola showed high concordance with the manual method in the inoculation of various body fluids, especially in blood culture sample. The use of Previ Isola in clinical microbiology laboratories is expected to save considerable time and human resources. © 2018 Wiley Periodicals, Inc.

  15. Manually controlled neutron-activation system

    International Nuclear Information System (INIS)

    Johns, R.A.; Carothers, G.A.

    1982-01-01

    A manually controlled neutron activation system, the Manual Reactor Activation System, was designed and built and has been operating at one of the Savannah River Plant's production reactors. With this system, samples can be irradiated for up to 24 hours and pneumatically transferred to a shielded repository for decay until their activity is low enough for them to be handled at a radiobench. The Manual Reactor Activation System was built to provide neutron activation of solid waste forms for the Alternative Waste Forms Leach Testing Program. Neutron activation of the bulk sample prior to leaching permits sensitive multielement radiometric analyses of the leachates

  16. Host Families Matter: The Homestay Manual.

    Science.gov (United States)

    Peace Corps, Washington, DC. Information Collection and Exchange Div.

    This manual provides guidelines, sample documents, and sample lesson plans for the trainers, trainees, and host families involved in homestays for Peace Corps volunteers. The manual contains 11 sections that deal with the following topics: (1) introduction; (2) policy, timelines, and responsibilities; (3) medical and financial issues; (4) host…

  17. Validity and Psychometric Properties of Malay Translated Religious Orientation Scale-Revised among Malaysian Adult Samples

    Directory of Open Access Journals (Sweden)

    Mohammad Rahim Kamaluddin

    2017-08-01

    Full Text Available Religious Orientation Scale-Revised (ROS-R has been used increasingly as an important measure in psychology of religion based researches and widely administered in cross-cultural settings. Unfortunately, there is no valid and reliable ROS-R available in Malay language to assess religious orientations among Malaysians. With that in mind, the present study aims to validate and document the psychometric properties of Malay translated ROS-R (henceforth, M-ROS-R among sample of Malaysian adults. This study commenced with Forward-Backward translations and was followed by content and face validities. Subsequently, a cross-sectional study was conducted among Malaysian adults (n = 226 using convenience sampling method for the purpose of construct and factorial validations. Later, construct and factorial validity was performed via Exploratory Factor Analysis using Principal Component Analysis with Varimax rotation. Finally, reliability testing was performed to determine the internal consistency of the items which was achieved using Cronbach’s Alpha coefficient method (α. The factor loading consisted of three factors with a total variance of 64.76%. The final version of M-ROS-R consisted of 14 items with Factor 1 (Intrinsic Orientation comprised of 8 items, Factor 2 (Extrinsic-Socially Orientated with 3 items while Factor 3 (Extrinsic-Personally Orientated constituted 3 items. The internal consistency values of the factors ranged between 0.68 and 0.86, indicating the scale is reliable. The intercorrelations between factors were also significant with each other. M-ROS-R was concluded as a valid and reliable scale to measure and assess religious orientations among Malaysians.

  18. Microbial ecology laboratory procedures manual NASA/MSFC

    Science.gov (United States)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  19. HASL procedures manual

    International Nuclear Information System (INIS)

    Harley, J.H.

    1977-08-01

    Additions and corrections to the following sections of the HASL Procedures Manual are provided: General, Sampling, Field Measurements; General Analytical Chemistry, Chemical Procedures, Data Section, and Specifications

  20. Validity and Psychometric Properties of Malay Translated Religious Orientation Scale-Revised among Malaysian Adult Samples

    OpenAIRE

    Mohammad Rahim Kamaluddin; Rohany Nasir; Wan Shahrazad Wan Sulaiman; Rozainee Khairudin; Zainah Ahmad Zamani

    2017-01-01

    Religious Orientation Scale-Revised (ROS-R) has been used increasingly as an important measure in psychology of religion based researches and widely administered in cross-cultural settings. Unfortunately, there is no valid and reliable ROS-R available in Malay language to assess religious orientations among Malaysians. With that in mind, the present study aims to validate and document the psychometric properties of Malay translated ROS-R (henceforth, M-ROS-R) among sample of Malay...

  1. Effect of Exogenous Cues on Covert Spatial Orienting in Deaf and Normal Hearing Individuals.

    Science.gov (United States)

    Prasad, Seema Gorur; Patil, Gouri Shanker; Mishra, Ramesh Kumar

    2015-01-01

    Deaf individuals have been known to process visual stimuli better at the periphery compared to the normal hearing population. However, very few studies have examined attention orienting in the oculomotor domain in the deaf, particularly when targets appear at variable eccentricity. In this study, we examined if the visual perceptual processing advantage reported in the deaf people also modulates spatial attentional orienting with eye movement responses. We used a spatial cueing task with cued and uncued targets that appeared at two different eccentricities and explored attentional facilitation and inhibition. We elicited both a saccadic and a manual response. The deaf showed a higher cueing effect for the ocular responses than the normal hearing participants. However, there was no group difference for the manual responses. There was also higher facilitation at the periphery for both saccadic and manual responses, irrespective of groups. These results suggest that, owing to their superior visual processing ability, the deaf may orient attention faster to targets. We discuss the results in terms of previous studies on cueing and attentional orienting in deaf.

  2. The interaction of birth order and parental age on sexual orientation: an examination in two samples.

    Science.gov (United States)

    Bogaert, Anthony F; Cairney, John

    2004-01-01

    A birth order and sexual orientation relationship has been demonstrated numerous times in men, but a related variable, parental age (i.e. age of parents when the participant was born), has been less studied and has demonstrated contradictory results. In this research, the relations among birth order, parental age and sexual orientation were examined in a national probability sample of the US (Kessler, 1994; Kessler et al., 1994) and in a Canadian sample of homosexual and heterosexual men closely matched on demographic characteristics (Blanchard & Bogaert, 1996a). In both studies, an interaction between birth order and parental age was observed in men, such that there was positive association between number of older siblings and the likelihood of homosexuality, but this association weakened with increasing parental age. No significant effects were observed for women. The results are discussed in relation to recent theories of the birth order/sexual orientation relationship.

  3. EML procedures manual

    International Nuclear Information System (INIS)

    Volchok, H.L.; de Planque, G.

    1982-01-01

    This manual contains the procedures that are used currently by the Environmental Measurements Laboratory of the US Department of Energy. In addition a number of analytical methods from other laboratories have been included. These were tested for reliability at the Battelle, Pacific Northwest Laboratory under contract with the Division of Biomedical and Environmental Research of the AEC. These methods are clearly distinguished. The manual is prepared in loose leaf form to facilitate revision of the procedures and inclusion of additional procedures or data sheets. Anyone receiving the manual through EML should receive this additional material automatically. The contents are as follows: (1) general; (2) sampling; (3) field measurements; (4) general analytical chemistry; (5) chemical procedures; (6) data section; (7) specifications

  4. An exploratory study of differences in views of factors affecting sexual orientation for a sample of lesbians and gay men.

    Science.gov (United States)

    Otis, Melanie D; Skinner, William F

    2004-06-01

    An exploratory study of lesbians (70) and gay men (118) from a rural state in the mid-South was conducted using a self-administered, mail-out survey. The nonrandom sample was drawn from organizational mailing lists, snowball sampling, and a convenience sample at a community event. Respondents were asked to indicate the extent to which each of the following affected sexual orientation: genetics, relationship between parents, relationship with parents, birth order, peers, growing up in a dysfunctional family, growing up in a single-parent family, negative experiences with the opposite sex, and positive experiences with the same sex. Similar to studies of heterosexual men and women, these gay men were more likely to view sexual orientation as a result of genetics than the lesbian respondents. Further, the lesbian group were more likely to view positive relationships with the same sex to have a great influence on sexual orientation. These data indicate there are sex differences in views on factors that affect sexual orientation.

  5. Manual versus automated blood sampling

    DEFF Research Database (Denmark)

    Teilmann, A C; Kalliokoski, Otto; Sørensen, Dorte B

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters......, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal...... corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters...

  6. On the aspiration characteristics of large-diameter, thin-walled aerosol sampling probes at yaw orientations with respect to the wind

    International Nuclear Information System (INIS)

    Vincent, J.H.; Mark, D.; Smith, T.A.; Stevens, D.C.; Marshall, M.

    1986-01-01

    Experiments were carried out in a large wind tunnel to investigate the aspiration efficiencies of thin-walled aerosol sampling probes of large diameter (up to 50 mm) at orientations with respect to the wind direction ranging from 0 to 180 degrees. Sampling conditions ranged from sub-to super-isokinetic. The experiments employed test dusts of close-graded fused alumina and were conducted under conditions of controlled freestream turbulence. For orientations up to and including 90 degrees, the results were qualitatively and quantitatively consistent with a new physical model which takes account of the fact that the sampled air not only diverges or converges (depending on the relationship between wind speed and sampling velocity) but also turns to pass through the plane of the sampling orifice. The previously published results of Durham and Lundgren (1980) and Davies and Subari (1982) for smaller probes were also in good agreement with the new model. The model breaks down, however, for orientations greater than 90 degrees due to the increasing effect of particle impaction onto the blunt leading edge of the probe body. For the probe facing directly away from the wind (180 degree orientation), aspiration efficiency is dominated almost entirely by this effect. (author)

  7. Variation in orgasm occurrence by sexual orientation in a sample of U.S. singles.

    Science.gov (United States)

    Garcia, Justin R; Lloyd, Elisabeth A; Wallen, Kim; Fisher, Helen E

    2014-11-01

    Despite recent advances in understanding orgasm variation, little is known about ways in which sexual orientation is associated with men's and women's orgasm occurrence. To assess orgasm occurrence during sexual activity across sexual orientation categories. Data were collected by Internet questionnaire from 6,151 men and women (ages 21-65+ years) as part of a nationally representative sample of single individuals in the United States. Analyses were restricted to a subsample of 2,850 singles (1,497 men, 1,353 women) who had experienced sexual activity in the past 12 months. Participants reported their sex/gender, self-identified sexual orientation (heterosexual, gay/lesbian, bisexual), and what percentage of the time they experience orgasm when having sex with a familiar partner. Mean occurrence rate for experiencing orgasm during sexual activity with a familiar partner was 62.9% among single women and 85.1% among single men, which was significantly different (F1,2848  = 370.6, P sexual orientation: heterosexual men 85.5%, gay men 84.7%, bisexual men 77.6% (F2,1494  = 2.67, P = 0.07, η(2)  = 0.004). For women, however, mean occurrence rate of orgasm varied significantly by sexual orientation: heterosexual women 61.6%, lesbian women 74.7%, bisexual women 58.0% (F2,1350  = 10.95, P sexual orientation, have less predictable, more varied orgasm experiences than do men and that for women, but not men, the likelihood of orgasm varies with sexual orientation. These findings demonstrate the need for further investigations into the comparative sexual experiences and sexual health outcomes of sexual minorities. © 2014 International Society for Sexual Medicine.

  8. Determinants and magnitudes of manual force strengths and joint moments during two-handed standing maximal horizontal pushing and pulling.

    Science.gov (United States)

    Chow, Amy Y; Dickerson, Clark R

    2016-04-01

    Pushing and pulling are common occupational exertions that are increasingly associated with musculoskeletal complaints. This study focuses on the sensitivity of shoulder capacity to gender, handle height, exertion type (push or pull) and handle orientation for these tasks. All factors except for handle orientation influenced unilateral and total manual force strength (p pushing and pulling tasks for a diverse population. Practitioner Summary: pushing and pulling comprise nearly half of all manual materials handling tasks. Practitioners often assess, design or modify these tasks while incorporating constraints, including manual force direction and handle interface. This study provides guidance to aid design of pushing and pulling tasks in the context of shoulder physical capacity.

  9. Comparison of semiautomated bird song recognition with manual detection of recorded bird song samples

    Directory of Open Access Journals (Sweden)

    Lisa A. Venier

    2017-12-01

    Full Text Available Automated recording units are increasingly being used to sample wildlife populations. These devices can produce large amounts of data that are difficult to process manually. However, the information in the recordings can be summarized with semiautomated sound recognition software. Our objective was to assess the utility of the semiautomated bird song recognizers to produce data useful for conservation and sustainable forest management applications. We compared detection data generated from expert-interpreted recordings of bird songs collected with automated recording units and data derived from a semiautomated recognition process. We recorded bird songs at 109 sites in boreal forest in 2013 and 2014 using automated recording units. We developed bird-song recognizers for 10 species using Song Scope software (Wildlife Acoustics and each recognizer was used to scan a set of recordings that was also interpreted manually by an expert in birdsong identification. We used occupancy models to estimate the detection probability associated with each method. Based on these detection probability estimates we produced cumulative detection probability curves. In a second analysis we estimated detection probability of bird song recognizers using multiple 10-minute recordings for a single station and visit (35-63, 10-minute recordings in each of four one-week periods. Results show that the detection probability of most species from single 10-min recordings is substantially higher using expert-interpreted bird song recordings than using the song recognizer software. However, our results also indicate that detection probabilities for song recognizers can be significantly improved by using more than a single 10-minute recording, which can be easily done with little additional cost with the automate procedure. Based on these results we suggest that automated recording units and song recognizer software can be valuable tools to estimate detection probability and

  10. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, RW; Dirkes, RL

    1990-02-01

    This manual establishes the procedures for the collection of environmental samples and the performance of radiation surveys and other field measurements. Responsibilities are defined for those personnel directly involved in the collection of samples and the performance of field measurements.

  11. The Navruz Project: Transboundary Monitoring for Radionuclides and Metals in Central Asia Rivers. Sampling and Analysis Plan and Operational Manual

    International Nuclear Information System (INIS)

    Passell, Howard D.; Barber, David S.; Betsill, J. David; Littlfield, Adriane C.; Mohagheghi, Amir H.; Shanks, Sonoya T.; Yuldashev, Bekhzad; Salikhbaev, Umar; Radyuk, Raisa; Djuraev, Akram; Djuraev, Amwar; Vasilev, Ivan; Tolongutov, Bajgabyl; Valentina, Alekhina; Solodukhin, Vladimir; Pozniak, Victor

    2002-01-01

    The transboundary nature of water resources demands a transboundary approach to their monitoring and management. However, transboundary water projects raise a challenging set of problems related to communication issues, and standardization of sampling, analysis and data management methods. This manual addresses those challenges and provides the information and guidance needed to perform the Navruz Project, a cooperative, transboundary, river monitoring project involving rivers and institutions in Kazakhstan, Kyrgyzstan, Tajikistan, and Uzbekistan facilitated by Sandia National Laboratories in the U.S. The Navruz Project focuses on waterborne radionuclides and metals because of their importance to public health and nuclear materials proliferation concerns in the region. This manual provides guidelines for participants on sample and data collection, field equipment operations and procedures, sample handling, laboratory analysis, and data management. Also included are descriptions of rivers, sampling sites and parameters on which data are collected. Data obtained in this project are shared among all participating countries and the public through an internet web site, and are available for use in further studies and in regional transboundary water resource management efforts. Overall, the project addresses three main goals: to help increase capabilities in Central Asian nations for sustainable water resources management; to provide a scientific basis for supporting nuclear transparency and non-proliferation in the region; and to help reduce the threat of conflict in Central Asia over water resources, proliferation concerns, or other factors.

  12. The Navruz Project: Transboundary Monitoring for Radionuclides and Metals in Central Asia Rivers. Sampling and Analysis Plan and Operational Manual

    Energy Technology Data Exchange (ETDEWEB)

    Passell, Howard D.; Barber, David S.; Betsill, J. David; Littlfield, Adriane C.; Mohagheghi, Amir H.; Shanks, Sonoya T.; Yuldashev, Bekhzad; Salikhbaev, Umar; Radyuk, Raisa; Djuraev, Akram; Djuraev, Amwar; Vasilev, Ivan; Tolongutov, Bajgabyl; Valentina, Alekhina; Solodukhin, Vladimir; Pozniak, Victor

    2002-04-02

    The transboundary nature of water resources demands a transboundary approach to their monitoring and management. However, transboundary water projects raise a challenging set of problems related to communication issues, and standardization of sampling, analysis and data management methods. This manual addresses those challenges and provides the information and guidance needed to perform the Navruz Project, a cooperative, transboundary, river monitoring project involving rivers and institutions in Kazakhstan, Kyrgyzstan, Tajikistan, and Uzbekistan facilitated by Sandia National Laboratories in the U.S. The Navruz Project focuses on waterborne radionuclides and metals because of their importance to public health and nuclear materials proliferation concerns in the region. This manual provides guidelines for participants on sample and data collection, field equipment operations and procedures, sample handling, laboratory analysis, and data management. Also included are descriptions of rivers, sampling sites and parameters on which data are collected. Data obtained in this project are shared among all participating countries and the public through an internet web site, and are available for use in further studies and in regional transboundary water resource management efforts. Overall, the project addresses three main goals: to help increase capabilities in Central Asian nations for sustainable water resources management; to provide a scientific basis for supporting nuclear transparency and non-proliferation in the region; and to help reduce the threat of conflict in Central Asia over water resources, proliferation concerns, or other factors.

  13. Management Information System Project. Data Processors Manual to the Program Oriented Accounting System: The Budgetary Process.

    Science.gov (United States)

    Foley, Walter; Harr, Gordon

    The purpose of this manual is to serve the needs of a data processing facility in the operation of a management information system (MIS). Included in the manual are system flowcharts, job control language, and system documentation. The system has been field tested and operates under IBM System 360/Model 65-05-MVT-HASP. The programing language is…

  14. Human manual control performance in hyper-gravity.

    Science.gov (United States)

    Clark, Torin K; Newman, Michael C; Merfeld, Daniel M; Oman, Charles M; Young, Laurence R

    2015-05-01

    Hyper-gravity provides a unique environment to study how misperceptions impact control of orientation relative to gravity. Previous studies have found that static and dynamic roll tilts are perceptually overestimated in hyper-gravity. The current investigation quantifies how this influences control of orientation. We utilized a long-radius centrifuge to study manual control performance in hyper-gravity. In the dark, subjects were tasked with nulling out a pseudo-random roll disturbance on the cab of the centrifuge using a rotational hand controller to command their roll rate in order to remain perceptually upright. The task was performed in 1, 1.5, and 2 G's of net gravito-inertial acceleration. Initial performance, in terms of root-mean-square deviation from upright, degraded in hyper-gravity relative to 1 G performance levels. In 1.5 G, initial performance degraded by 26 % and in 2 G, by 45 %. With practice, however, performance in hyper-gravity improved to near the 1 G performance level over several minutes. Finally, pre-exposure to one hyper-gravity level reduced initial performance decrements in a different, novel, hyper-gravity level. Perceptual overestimation of roll tilts in hyper-gravity leads to manual control performance errors, which are reduced both with practice and with pre-exposure to alternate hyper-gravity stimuli.

  15. Space Flight and Manual Control: Implications for Sensorimotor Function on Future Missions

    Science.gov (United States)

    Reschke, Millard F.; Kornilova, Ludmila; Tomilovskaya, Elena; Parker, Donald E.; Leigh, R. John; Kozlovskaya, Inessa

    2009-01-01

    Control of vehicles, and other complex mechanical motion systems, is a high-level integrative function of the central nervous system (CNS) that requires good visual acuity, eye-hand coordination, spatial (and, in some cases, geographic) orientation perception, and cognitive function. Existing evidence from space flight research (Paloski et.al., 2008, Clement and Reschke 2008, Reschke et al., 2007) demonstrates that the function of each of these systems is altered by removing (and subsequently by reintroducing) a gravitational field that can be sensed by vestibular, proprioceptive, and haptic receptors and used by the CNS for spatial orientation, navigation, and coordination of movements. Furthermore, much of the operational performance data collected as a function of space flight has not been available for independent analysis, and those data that have been reviewed are equivocal owing to uncontrolled environmental and/or engineering factors. Thus, our current understanding, when it comes to manual control, is limited primarily to a review of those situations where manual control has been a factor. One of the simplest approaches to the manual control problem is to review shuttle landing data. See the Figure below for those landing for which we have Shuttle velocities over the runway threshold.

  16. Crystal orientation and sample preparation effects on sputtering and lattice damage in 100 keV self-irradiated copper

    International Nuclear Information System (INIS)

    Sprague, J.A.; Malmberg, P.R.; Reynolds, G.W.; Lambert, J.M.; Treado, P.A.; Vincenz, A.M.

    1987-01-01

    Sputtering yields and angular distributions have been measured as functions of sample preparation techniques and incident ion-beam orientation with respect to the crystal axes for 100 keV Cu-ion beams on Cu crystals and polycrystalline samples. The angular distributions have structure requiring an nth order cosine with two Gaussians superimposed to fit the data; strong peaking is observed near the backscatter direction. The yield is dependent on the beam to crystal and beam to polycrystalline-rod axis orientation, on the grain size of the polycrystals and on sample-preparation techniques. Yield measurements vary by as much as a factor of 4. Lattice-damage differences, measured with alpha particle channeling, are much smaller and seem to be saturated by fluences of the order of 1x10 16 /cm 2 . (orig.)

  17. Subsurface Noble Gas Sampling Manual

    Energy Technology Data Exchange (ETDEWEB)

    Carrigan, C. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sun, Y. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-18

    The intent of this document is to provide information about best available approaches for performing subsurface soil gas sampling during an On Site Inspection or OSI. This information is based on field sampling experiments, computer simulations and data from the NA-22 Noble Gas Signature Experiment Test Bed at the Nevada Nuclear Security Site (NNSS). The approaches should optimize the gas concentration from the subsurface cavity or chimney regime while simultaneously minimizing the potential for atmospheric radioxenon and near-surface Argon-37 contamination. Where possible, we quantitatively assess differences in sampling practices for the same sets of environmental conditions. We recognize that all sampling scenarios cannot be addressed. However, if this document helps to inform the intuition of the reader about addressing the challenges resulting from the inevitable deviations from the scenario assumed here, it will have achieved its goal.

  18. Canopy Version 7.0: Canopy manual

    International Nuclear Information System (INIS)

    Fischler, M.; Uchima, M.; Hockney, G.; Mackenzie, P.

    1993-12-01

    Canopy provides a machine-independent environment for attacking grid-oriented problems. This document describes the concepts and routines common to all Canopy implementations, independent of the system and implementation. Information specific to the massively parallel ACPMAPS/indexACPMAPS system at FermiLab is contained in two other documents: The CANOPY ACPMAPS USER's GUIDE provides user-oriented instructions on compiling, running, file system usage, and production job control. The CANOPY ACPMAPS SYSTEM MANUAL describes system tools and installation and system management techniques. System-specific User's Guides may be created for implementations on other systems. The goal of Canopy is to allow scientists to use massively parallel systems for a broad class of applications without having to become expert in any particular system or in parallel programming techniques. The Canopy approach identifies grid-oriented concepts and implements them as routines in a library. Applications written in terms of these concepts will run on any system which supports the Canopy software. A side benefit in dealing with familiar concepts is that programs can more easily be understood by other researchers

  19. Manual for troubleshooting and upgrading of neutron generators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    This manual is intended to assist operators in troubleshooting and upgrading of neutron generators. It is directed particularly to operators and technicians in less experienced laboratories and therefore the descriptions of the principles and techniques of these machines are operator oriented. In addition to a discussion of the main characteristics of neutron generators, detailed information is given on the function of particular commercial units, on common problems related to specific components of accelerators, and on methods of troubleshooting and repair. Detailed schematic and circuit diagrams are provided to help operators in the development and improvement of the generators. The problems treated in the Manual have been collected during several IAEA missions in developing countries. 125 refs, 161 figs, 22 tabs.

  20. Manual for troubleshooting and upgrading of neutron generators

    International Nuclear Information System (INIS)

    1996-11-01

    This manual is intended to assist operators in troubleshooting and upgrading of neutron generators. It is directed particularly to operators and technicians in less experienced laboratories and therefore the descriptions of the principles and techniques of these machines are operator oriented. In addition to a discussion of the main characteristics of neutron generators, detailed information is given on the function of particular commercial units, on common problems related to specific components of accelerators, and on methods of troubleshooting and repair. Detailed schematic and circuit diagrams are provided to help operators in the development and improvement of the generators. The problems treated in the Manual have been collected during several IAEA missions in developing countries. 125 refs, 161 figs, 22 tabs

  1. Fourier descriptors analysis of anisotropy and preferred Orientation in geological samples

    International Nuclear Information System (INIS)

    Santiago Buey, C. de

    2011-01-01

    This study focuses on the use of Fourier descriptors to evaluate and quantify two specific fabric characteristics of geological materials: anisotropy of particles or voids morphologies and particle orientation. To this end, a theoretical section of a rock was created, made of ellipses and rectangles of different axes ratios and different orientations. The Fourier descriptors method was applied to calculate the anisotropy and orientation of each particle and, finally, a rose diagram was constructed to represent the particles orientations distribution and to observe the presence or not of any preferred orientation. (Author) 15 refs.

  2. Pollutant Assessments Group procedures manual: Volume 2, Technical procedures

    Energy Technology Data Exchange (ETDEWEB)

    1992-03-01

    This is volume 2 of the manuals that describes the technical procedures currently in use by the Pollution Assessments Group. This manual incorporates new developments in hazardous waste assessment technology and administrative policy. Descriptions of the equipment, procedures and operations of such things as radiation detection, soil sampling, radionuclide monitoring, and equipment decontamination are included in this manual. (MB)

  3. Nuclear material operations manual

    International Nuclear Information System (INIS)

    Tyler, R.P.

    1981-02-01

    This manual provides a concise and comprehensive documentation of the operating procedures currently practiced at Sandia National Laboratories with regard to the management, control, and accountability of nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations-management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of playscripts in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  4. Nuclear material operations manuals

    International Nuclear Information System (INIS)

    Tyler, R.P.

    1979-06-01

    This manual is intended to provide a concise and comprehensive documentation of the operating procedures currently practiced at Sandia Laboratories with regard to the management, control, and accountability of radioactive and nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations-management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of playscripts in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  5. Dissociated effects of distractors on saccades and manual aiming.

    Science.gov (United States)

    McIntosh, Robert D; Buonocore, Antimo

    2012-08-01

    The remote distractor effect (RDE) is a robust phenomenon whereby target-directed saccades are delayed by the appearance of a distractor. This effect persists even when the target location is perfectly predictable. The RDE has been studied extensively in the oculomotor domain but it is unknown whether it generalises to other spatially oriented responses. In three experiments, we tested whether the RDE generalises to manual aiming. Experiment 1 required participants to move their hand or eyes to predictable targets presented alone or accompanied by a distractor in the opposite hemifield. The RDE was observed for the eyes but not for the hand. Experiment 2 replicated this dissociation in a more naturalistic task in which eye movements were not constrained during manual aiming. Experiment 3 confirmed the lack of manual RDE across a wider range of distractor delays (0, 50, 100, and 150 ms). Our data imply that the RDE is specific to the oculomotor system, at least for non-foveal distractors. We suggest that the oculomotor RDE reflects competitive interactions between target and distractor representations in the superior colliculus, which are not necessarily shared by manual aiming.

  6. New Mexico Response to Intervention Framework Manual

    Science.gov (United States)

    New Mexico Public Education Department, 2014

    2014-01-01

    This manual details the instructional framework and guidance on the Response to Intervention (RtI) process in New Mexico. The manual includes: (1) a section on each of the three instructional tiers; (2) a glossary of key terms; (3) sample forms to assist with the Student Assistance Team (SAT) process; and (4) key resources for teachers.

  7. GO methodology. Volume 1. Overview manual

    International Nuclear Information System (INIS)

    1983-06-01

    The GO methodology is a success-oriented probabilistic system performance analysis technique. The methodology can be used to quantify system reliability and availability, identify and rank critical components and the contributors to system failure, construct event trees, and perform statistical uncertainty analysis. Additional capabilities of the method currently under development will enhance its use in evaluating the effects of external events and common cause failures on system performance. This Overview Manual provides a description of the GO Methodology, how it can be used, and benefits of using it in the analysis of complex systems

  8. Automatic orientation and 3D modelling from markerless rock art imagery

    Science.gov (United States)

    Lerma, J. L.; Navarro, S.; Cabrelles, M.; Seguí, A. E.; Hernández, D.

    2013-02-01

    This paper investigates the use of two detectors and descriptors on image pyramids for automatic image orientation and generation of 3D models. The detectors and descriptors replace manual measurements and are used to detect, extract and match features across multiple imagery. The Scale-Invariant Feature Transform (SIFT) and the Speeded Up Robust Features (SURF) will be assessed based on speed, number of features, matched features, and precision in image and object space depending on the adopted hierarchical matching scheme. The influence of applying in addition Area Based Matching (ABM) with normalised cross-correlation (NCC) and least squares matching (LSM) is also investigated. The pipeline makes use of photogrammetric and computer vision algorithms aiming minimum interaction and maximum accuracy from a calibrated camera. Both the exterior orientation parameters and the 3D coordinates in object space are sequentially estimated combining relative orientation, single space resection and bundle adjustment. The fully automatic image-based pipeline presented herein to automate the image orientation step of a sequence of terrestrial markerless imagery is compared with manual bundle block adjustment and terrestrial laser scanning (TLS) which serves as ground truth. The benefits of applying ABM after FBM will be assessed both in image and object space for the 3D modelling of a complex rock art shelter.

  9. Nuclear material operations manual

    International Nuclear Information System (INIS)

    Tyler, R.P.; Gassman, L.D.

    1978-04-01

    This manual is intended to provide a concise and comprehensive documentation of the operating procedures currently practiced at Sandia Laboratories with regard to the management, control, and accountability of radioactive and nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations--management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of ''play-scripts'' in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  10. Interlimb Transfer of Grasp Orientation is Asymmetrical

    Directory of Open Access Journals (Sweden)

    Victor Frak

    2006-01-01

    Full Text Available One the most fundamental aspects of the human motor system is the hemispheric asymmetry seen in behavioral specialization. Hemispheric dominance can be inferred by a contralateral hand preference in grasping. Few studies have considered grasp orientation in the context of manual lateralization and none has looked at grasp orientation with natural prehension. Thirty right-handed adults performed precision grasps of a cylinder using the thumb and index fingers, and the opposition axis (OA was defined as the line connecting these two contact points on the cylinder. Subjects made ten consecutive grasps with one hand (primary hand movements followed by ten grasps with the other hand (trailing movements. Differences between primary and trailing grasps revealed that each hemisphere is capable of programming the orientation of the OA and that primary movements with the right hand significantly influenced OA orientation of the trailing left hand. These results extend the hemispheric dominance of the left hemisphere to the final positions of fingers during prehension.

  11. The environmental survey manual

    International Nuclear Information System (INIS)

    1987-08-01

    The purpose of this manual is to provide guidance to the Survey and Sampling and Analysis teams that conduct the one-time Environmental Survey of the major US Department of Energy (DOE) operating facilities. This manual includes a discussion of DOE's policy on environmental issues, a review of statutory guidance as it applies to the Survey, the procedures and protocols to be used by the Survey teams, criteria for the use of the Survey teams in evaluating existing environmental data for the Survey effort, generic technical checklists used in every Survey, health and safety guidelines for the personnel conducting the Survey, including the identification of potential hazards, prescribed protective equipment, and emergency procedures, the required formats for the Survey reports, guidance on identifying environmental problems that need immediate attention by the Operations Office responsible for the particular facility, and procedures and protocols for the conduct of sampling and analysis

  12. Scapular kinematics during manual wheelchair propulsion in able-bodied participants.

    Science.gov (United States)

    Bekker, Michel J; Vegter, Riemer J K; van der Scheer, Jan W; Hartog, Johanneke; de Groot, Sonja; de Vries, Wiebe; Arnet, Ursina; van der Woude, Lucas H V; Veeger, Dirkjan H E J

    2018-05-01

    Altered scapular kinematics have been associated with shoulder pain and functional limitations. To understand kinematics in persons with spinal cord injury during manual handrim wheelchair propulsion, a description of normal scapular behaviour in able-bodied persons during this specific task is a prerequisite for accurate interpretation. The primary aim of this study is to describe scapular kinematics in able-bodied persons during manual wheelchair propulsion. Sixteen able-bodied, novice wheelchair users without shoulder complaints participated in the study. Kinematic and kinetic data were collected during a standardized pose in the anatomic posture, frontal-plane arm elevation and low-intensity steady-state handrim wheelchair propulsion and upper-body Euler angles were calculated. Scapulothoracic joint orientations in a static position were 36.7° (SD 5.4°), 6.4° (SD 9.1°) and 9.1° (SD 5.7°) for respectively protraction, lateral rotation and anterior tilt. At 80° of arm elevation in the frontal plane, the respective values of 33.4° (SD 8.0°), 23.9° (SD 5.4°) and 4.1° (SD 11.3°) were found. During the push phase of manual wheelchair propulsion, the mean scapular rotations were respectively 32.7° (SD 7.1°), 7.1° (SD 9.2°) and 9.8° (SD 8.3°). The orientation of the scapula in a static pose, during arm elevation and in manual wheelchair propulsion in able-bodied participants showed similar patterns to a previous study in persons with para- and tetraplegia. These values provide a reference for the investigation of the scapular movement pattern in wheelchair-dependent persons and its relation to shoulder complex abnormalities. Copyright © 2018. Published by Elsevier Ltd.

  13. Axially perpendicular offset Raman scheme for reproducible measurement of housed samples in a noncircular container under variation of container orientation.

    Science.gov (United States)

    Duy, Pham K; Chang, Kyeol; Sriphong, Lawan; Chung, Hoeil

    2015-03-17

    An axially perpendicular offset (APO) scheme that is able to directly acquire reproducible Raman spectra of samples contained in an oval container under variation of container orientation has been demonstrated. This scheme utilized an axially perpendicular geometry between the laser illumination and the Raman photon detection, namely, irradiation through a sidewall of the container and gathering of the Raman photon just beneath the container. In the case of either backscattering or transmission measurements, Raman sampling volumes for an internal sample vary when the orientation of an oval container changes; therefore, the Raman intensities of acquired spectra are inconsistent. The generated Raman photons traverse the same bottom of the container in the APO scheme; the Raman sampling volumes can be relatively more consistent under the same situation. For evaluation, the backscattering, transmission, and APO schemes were simultaneously employed to measure alcohol gel samples contained in an oval polypropylene container at five different orientations and then the accuracies of the determination of the alcohol concentrations were compared. The APO scheme provided the most reproducible spectra, yielding the best accuracy when the axial offset distance was 10 mm. Monte Carlo simulations were performed to study the characteristics of photon propagation in the APO scheme and to explain the origin of the optimal offset distance that was observed. In addition, the utility of the APO scheme was further demonstrated by analyzing samples in a circular glass container.

  14. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    RW Hanf; TM Poston

    2000-09-20

    Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual.

  15. Who takes more sustainability-oriented entrepreneurial actions? The role of entrepreneurs' values, beliefs and orientations

    DEFF Research Database (Denmark)

    Jahanshahi, Asghar Afshar; Brem, Alexander; Bhattacharjee, Amitab

    2017-01-01

    We examine the relationships between entrepreneurs' values, beliefs and orientations with their firms' engagement in sustainability-oriented entrepreneurial actions, using a sample of 352 newly established businesses from two Asian countries (Bangladesh and Iran). Our results reveal a dual role o...... of sustainable entrepreneurship, by providing answers for recent calls for better understanding which entrepreneurial ventures engage more in sustainability-oriented actions.......We examine the relationships between entrepreneurs' values, beliefs and orientations with their firms' engagement in sustainability-oriented entrepreneurial actions, using a sample of 352 newly established businesses from two Asian countries (Bangladesh and Iran). Our results reveal a dual role...... of entrepreneurs' values, beliefs and orientations when taking sustainability-oriented actions. We confirm that individual differences in the set of values, beliefs and orientations can foster or hinder the sustainability-oriented actions across organizations. Our paper contributes to the growing literature...

  16. Fabrication and Molecular Transport Studies of Highly c-Oriented AFI Membranes

    KAUST Repository

    Liu, Yang; Zhang, Bing; Liu, Defei; Sheng, Ping; Lai, Zhiping

    2017-01-01

    -packed and c-oriented monolayer of plate-like seeds that is manually assembled on a porous alumina support. The straight channels in the membrane are not only aligned vertically along the membrane depth, but are also continuous without disruption. The transport

  17. VLE measurements using a static cell vapor phase manual sampling method accompanied with an empirical data consistency test

    International Nuclear Information System (INIS)

    Freitag, Joerg; Kosuge, Hitoshi; Schmelzer, Juergen P.; Kato, Satoru

    2015-01-01

    Highlights: • We use a new, simple static cell vapor phase manual sampling method (SCVMS) for VLE (x, y, T) measurement. • The method is applied to non-azeotropic, asymmetric and two-liquid phase forming azeotropic binaries. • The method is approved by a data consistency test, i.e., a plot of the polarity exclusion factor vs. pressure. • The consistency test reveals that with the new SCVMS method accurate VLE near ambient temperature can be measured. • Moreover, the consistency test approves that the effect of air in the SCVMS system is negligible. - Abstract: A new static cell vapor phase manual sampling (SCVMS) method is used for the simple measurement of constant temperature x, y (vapor + liquid) equilibria (VLE). The method was applied to the VLE measurements of the (methanol + water) binary at T/K = (283.2, 298.2, 308.2 and 322.9), asymmetric (acetone + 1-butanol) binary at T/K = (283.2, 295.2, 308.2 and 324.2) and two-liquid phase forming azeotropic (water + 1-butanol) binary at T/K = (283.2 and 298.2). The accuracy of the experimental data was approved by a data consistency test, that is, an empirical plot of the polarity exclusion factor, β, vs. the system pressure, P. The SCVMS data are accurate, because the VLE data converge to the same lnβ vs. lnP straight line determined from conventional distillation-still method and a headspace gas chromatography method

  18. Field manual for stream water and sediment reconnaissance

    International Nuclear Information System (INIS)

    Ferguson, R.B.; Price, V.; Baucom, E.I.

    1977-11-01

    A manual is presented that is intended to direct and coordinate field operations, site selection, sample collection, and information codes for the Savannah River Laboratory (SRL) contribution to the National Uranium Resource Evaluation (NURE) program. The manual provides technical direction and public relations information for field sampling teams. The program is being conducted to evaluate domestic uranium resources and to identify favorable areas for commercial exploration. The NURE program is expected to increase the activity of commercial exploration for uranium in the United States

  19. BASINs 4.0 Climate Assessment Tool (CAT): Supporting Documentation and User's Manual (Final Report)

    Science.gov (United States)

    EPA announced the availability of the report, BASINS 4.0 Climate Assessment Tool (CAT): Supporting Documentation and User's Manual. This report was prepared by the EPA's Global Change Research Program (GCRP), an assessment-oriented program, that sits within the Office of R...

  20. Exploring the diversity of gender and sexual orientation identities in an online sample of transgender individuals.

    Science.gov (United States)

    Kuper, Laura E; Nussbaum, Robin; Mustanski, Brian

    2012-01-01

    Although the term transgender is increasingly used to refer to those whose gender identity or expression diverges from culturally defined categories of sex and gender, less is known about the self-identities of those who fall within this category. Historically, recruitment of transgender populations has also been limited to specialized clinics and support groups. This study was conducted online, with the aim of exploring the gender identities, sexual orientation identities, and surgery and hormonal statuses of those who identify with a gender identity other than, or in addition to, that associated with their birth sex (n = 292). Genderqueer was the most commonly endorsed gender identity, and pansexual and queer were the most commonly endorsed sexual orientation identities. Participants indentified with a mean of 2.5 current gender identities, 1.4 past gender identities, and 2 past sexual orientation identities. The majority of participants either did not desire or were unsure of their desire to take hormones or undergo sexual reassignment surgery. However, birth sex and age were significant predictors of "bottom" surgery and hormone status/desire, along with several identities and orientations. This study explores explanations and implications for these patterns of identification, along with the potential distinctiveness of this sample.

  1. Message framing for health: moderation by perceived susceptibility and motivational orientation in a diverse sample of Americans.

    Science.gov (United States)

    Updegraff, John A; Brick, Cameron; Emanuel, Amber S; Mintzer, Roy E; Sherman, David K

    2015-01-01

    The present study examined how gain- and loss-framed informational videos about oral health influence self-reported flossing behavior over a 6-month period, as well as the roles of perceived susceptibility to oral health problems and approach/avoidance motivational orientation in moderating these effects. An age and ethnically diverse sample of 855 American adults were randomized to receive no health message, or either a gain-framed or loss-framed video presented on the Internet. Self-reported flossing was assessed longitudinally at 2 and 6 months. Among the entire sample, susceptibility interacted with frame to predict flossing. Participants who watched a video where the frame (gain/loss) matched perceived susceptibility (low/high) had significantly greater likelihood of flossing at recommended levels at the 6-month follow-up, compared with those who viewed a mismatched video or no video at all. However, young adults (18-24) showed stronger moderation by motivational orientation than by perceived susceptibility, in line with previous work largely conducted with young adult samples. Brief informational interventions can influence long-term health behavior, particularly when the gain- or loss-frame of the information matches the recipient's beliefs about their health outcome risks.

  2. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    OpenAIRE

    ?nce, Fatma Demet; Ellida?, Hamit Ya?ar; Koseo?lu, Mehmet; ?im?ek, Ne?e; Yal??n, H?lya; Zengin, Mustafa Osman

    2016-01-01

    Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA), Dirui...

  3. Quality manual for Laboratories of the Nuclear Materials Characterization Division

    International Nuclear Information System (INIS)

    Sabato, S.F.

    1991-05-01

    This publication presents the first Quality Manual for the Laboratories at the Nuclear Materials Characterization Division. The Manual describes the laboratories, its organization structure, fields of activities, personnel records, equipments, maintenance and calibration. The main aspects concerning quality assurance in the analysis were discussed. The whole system of receiving, identifying and processing analysis of the samples is shown. Since there are many information to be contained in several subjects of the Quality Manual, there were produced separate documents that are cross referenced in the manual. (author)

  4. Estimating Orientation Using Magnetic and Inertial Sensors and Different Sensor Fusion Approaches: Accuracy Assessment in Manual and Locomotion Tasks

    Directory of Open Access Journals (Sweden)

    Elena Bergamini

    2014-10-01

    Full Text Available Magnetic and inertial measurement units are an emerging technology to obtain 3D orientation of body segments in human movement analysis. In this respect, sensor fusion is used to limit the drift errors resulting from the gyroscope data integration by exploiting accelerometer and magnetic aiding sensors. The present study aims at investigating the effectiveness of sensor fusion methods under different experimental conditions. Manual and locomotion tasks, differing in time duration, measurement volume, presence/absence of static phases, and out-of-plane movements, were performed by six subjects, and recorded by one unit located on the forearm or the lower trunk, respectively. Two sensor fusion methods, representative of the stochastic (Extended Kalman Filter and complementary (Non-linear observer filtering, were selected, and their accuracy was assessed in terms of attitude (pitch and roll angles and heading (yaw angle errors using stereophotogrammetric data as a reference. The sensor fusion approaches provided significantly more accurate results than gyroscope data integration. Accuracy improved mostly for heading and when the movement exhibited stationary phases, evenly distributed 3D rotations, it occurred in a small volume, and its duration was greater than approximately 20 s. These results were independent from the specific sensor fusion method used. Practice guidelines for improving the outcome accuracy are provided.

  5. Manual for guided home exercises for osteoarthritis of the knee

    Directory of Open Access Journals (Sweden)

    Nilza Aparecida de Almeida Carvalho

    2010-06-01

    Full Text Available INTRODUCTION: Physiotherapy is one of the most important components of therapy for osteoarthritis of the knee. The objective of this prospective case series was to assess the efficiency of a guidance manual for patients with osteoarthritis of the knee in relation to pain, range of movement , muscle strength and function, active goniometry, manual strength test and function. METHODS: Thirty-eight adults with osteoarthritis of the knee (> 45 years old who were referred to the physiotherapy service at the university hospital (Santa Casa de Misericórdia de São Paulo were studied. Patients received guidance for the practice of specific physical exercises and a manual with instructions on how to perform the exercises at home. They were evaluated for pain, range of movement, muscle strength and function. These evaluations were performed before they received the manual and three months later. Patients were seen monthly regarding improvements in their exercising abilities. RESULTS: The program was effective for improving muscle strength, controlling pain, maintaining range of movement of the knee joint, and reducing functional incapacity. DISCUSSION: A review of the literature showed that there are numerous clinical benefits to the regular practice of physical therapy exercises by patients with osteoarthritis of the knee(s in a program with appropriate guidance. This study shows that this guidance can be attained at home with the use of a proper manual. CONCLUSIONS: Even when performed at home without constant supervision, the use of the printed manual for orientation makes the exercises for osteoarthritis of the knee beneficial.

  6. Sampling method of environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    1984-01-01

    This manual provides sampling methods of environmental samples of airborne dust, precipitated dust, precipitated water (rain or snow), fresh water, soil, river sediment or lake sediment, discharged water from a nuclear facility, grains, tea, milk, pasture grass, limnetic organisms, daily diet, index organisms, sea water, marine sediment, marine organisms, and that for tritium and radioiodine determination for radiation monitoring from radioactive fallout or radioactivity release by nuclear facilities. This manual aims at the presentation of standard sampling procedures for environmental radioactivity monitoring regardless of monitoring objectives, and shows preservation method of environmental samples acquired at the samplingpoint for radiation counting for those except human body. Sampling techniques adopted in this manual is decided by the criteria that they are suitable for routine monitoring and any special skillfulness is not necessary. Based on the above-mentioned principle, this manual presents outline and aims of sampling, sampling position or object, sampling quantity, apparatus, equipment or vessel for sampling, sampling location, sampling procedures, pretreatment and preparation procedures of a sample for radiation counting, necessary recording items for sampling and sample transportation procedures. Special attention is described in the chapter of tritium and radioiodine because these radionuclides might be lost by the above-mentioned sample preservation method for radiation counting of less volatile radionuclides than tritium or radioiodine. (Takagi, S.)

  7. Microscopic Analysis of Activated Sludge. Training Manual.

    Science.gov (United States)

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on the use of a compound microscope to analyze microscope communities, present in wastewater treatment processes, for operational control. Course topics include: sampling techniques, sample handling, laboratory analysis, identification of organisms, data interpretation, and use of the compound microscope.…

  8. Applications of the rotating orientation XRD method to oriented materials

    International Nuclear Information System (INIS)

    Guo Zhenqi; Li Fei; Jin Li; Bai Yu

    2009-01-01

    The rotating orientation x-ray diffraction (RO-XRD) method, based on conventional XRD instruments by a modification of the sample stage, was introduced to investigate the orientation-related issues of such materials. In this paper, we show its applications including the determination of single crystal orientation, assistance in crystal cutting and evaluation of crystal quality. The interpretation of scanning patterns by RO-XRD on polycrystals with large grains, bulk material with several grains and oriented thin film is also presented. These results will hopefully expand the applications of the RO-XRD method and also benefit the conventional XRD techniques. (fast track communication)

  9. Computer Processing 10-20-30. Teacher's Manual. Senior High School Teacher Resource Manual.

    Science.gov (United States)

    Fisher, Mel; Lautt, Ray

    Designed to help teachers meet the program objectives for the computer processing curriculum for senior high schools in the province of Alberta, Canada, this resource manual includes the following sections: (1) program objectives; (2) a flowchart of curriculum modules; (3) suggestions for short- and long-range planning; (4) sample lesson plans;…

  10. Peace Corps Aquaculture Training Manual. Training Manual T0057.

    Science.gov (United States)

    Peace Corps, Washington, DC. Information Collection and Exchange Div.

    This Peace Corps training manual was developed from two existing manuals to provide a comprehensive training program in fish production for Peace Corps volunteers. The manual encompasses the essential elements of the University of Oklahoma program that has been training volunteers in aquaculture for 25 years. The 22 chapters of the manual are…

  11. Message Framing for Health: Moderation by Perceived Susceptibility and Motivational Orientation in a Diverse Sample of Americans

    Science.gov (United States)

    Updegraff, John A.; Brick, Cameron; Emanuel, Amber S.; Mintzer, Roy E.; Sherman, David K.

    2015-01-01

    Objective The present study examined how gain- and loss-framed informational videos about oral health influence self-reported flossing behavior over a 6-month period, as well as the roles of perceived susceptibility to oral health problems and approach/avoidance motivational orientation in moderating these effects. Method An age and ethnically diverse sample of 855 American adults were randomized to receive no health message, or either a gain-framed or loss-framed video presented on the Internet. Self-reported flossing was assessed longitudinally at 2 and 6 months. Results Among the entire sample, susceptibility interacted with frame to predict flossing. Participants who watched a video where the frame (gain/loss) matched perceived susceptibility (low/high) had significantly greater likelihood of flossing at recommended levels at the 6-month follow-up, compared with those who viewed a mismatched video or no video at all. However, young adults (18–24) showed stronger moderation by motivational orientation than by perceived susceptibility, in line with previous work largely conducted with young adult samples. Conclusion Brief informational interventions can influence long-term health behavior, particularly when the gain- or loss-frame of the information matches the recipient’s beliefs about their health outcome risks. PMID:25020153

  12. ARIES NDA Robot operators' manual

    International Nuclear Information System (INIS)

    Scheer, N.L.; Nelson, D.C.

    1998-05-01

    The ARIES NDA Robot is an automation device for servicing the material movements for a suite of Non-destructive assay (NDA) instruments. This suite of instruments includes a calorimeter, a gamma isotopic system, a segmented gamma scanner (SGS), and a neutron coincidence counter (NCC). Objects moved by the robot include sample cans, standard cans, and instrument plugs. The robot computer has an RS-232 connection with the NDA Host computer, which coordinates robot movements and instrument measurements. The instruments are expected to perform measurements under the direction of the Host without operator intervention. This user's manual describes system startup, using the main menu, manual operation, and error recovery

  13. Field manual for stream sediment reconnaissance. Savannah River Laboratory National Uranium Resource Evaluation Program

    International Nuclear Information System (INIS)

    Ferguson, R.B.; Price, V.; Baucom, E.I.

    1976-07-01

    A manual is presented that is intended to direct and coordinate field operations, site selection, stream sediment sample collection, water sample collection, and information codes for the Savannah River Laboratory (SRL) contribution to the National Uranium Resource Evaluation (NURE) program. The manual provides public relations information for field sampling teams as well as technical direction

  14. Plenoptic background oriented schlieren imaging

    International Nuclear Information System (INIS)

    Klemkowsky, Jenna N; Fahringer, Timothy W; Clifford, Christopher J; Thurow, Brian S; Bathel, Brett F

    2017-01-01

    The combination of the background oriented schlieren (BOS) technique with the unique imaging capabilities of a plenoptic camera, termed plenoptic BOS, is introduced as a new addition to the family of schlieren techniques. Compared to conventional single camera BOS, plenoptic BOS is capable of sampling multiple lines-of-sight simultaneously. Displacements from each line-of-sight are collectively used to build a four-dimensional displacement field, which is a vector function structured similarly to the original light field captured in a raw plenoptic image. The displacement field is used to render focused BOS images, which qualitatively are narrow depth of field slices of the density gradient field. Unlike focused schlieren methods that require manually changing the focal plane during data collection, plenoptic BOS synthetically changes the focal plane position during post-processing, such that all focal planes are captured in a single snapshot. Through two different experiments, this work demonstrates that plenoptic BOS is capable of isolating narrow depth of field features, qualitatively inferring depth, and quantitatively estimating the location of disturbances in 3D space. Such results motivate future work to transition this single-camera technique towards quantitative reconstructions of 3D density fields. (paper)

  15. Automatic remote sampling and delivery system incorporating decontamination and disposal of sample bottles

    International Nuclear Information System (INIS)

    Savarkar, V.K.; Mishra, A.K.; Bajpai, D.D.; Nair, M.K.T.

    1990-01-01

    The present generation of reprocessing plants have sampling and delivery systems that have to be operated manually with its associated problems. The complete automation and remotisation of sampling system has hence been considered to reduce manual intervention and personnel exposure. As a part of this scheme an attempt to automate and remotise various steps in sampling system has been made. This paper discusses in detail the development work carried out in this area as well as the tests conducted to incorporate the same in the existing plants. (author). 3 figs

  16. Sample problem manual for benchmarking of cask analysis codes

    International Nuclear Information System (INIS)

    Glass, R.E.

    1988-02-01

    A series of problems have been defined to evaluate structural and thermal codes. These problems were designed to simulate the hypothetical accident conditions given in Title 10 of the Code of Federal Regulation, Part 71 (10CFR71) while retaining simple geometries. This produced a problem set that exercises the ability of the codes to model pertinent physical phenomena without requiring extensive use of computer resources. The solutions that are presented are consensus solutions based on computer analyses done by both national laboratories and industry in the United States, United Kingdom, France, Italy, Sweden, and Japan. The intent of this manual is to provide code users with a set of standard structural and thermal problems and solutions which can be used to evaluate individual codes. 19 refs., 19 figs., 14 tabs

  17. SES2D user's manual

    International Nuclear Information System (INIS)

    Johnson, J.D.; Lyon, S.P.

    1982-04-01

    SES2D is an interactive graphics code designed to generate plots of equation of state data from the Los Alamos National Laboratory Group T-4 computer libraries. This manual discusses the capabilities of the code. It describes the prompts and commands and illustrates their use with a sample run

  18. High School and Beyond Transcripts Survey (1982). Data File User's Manual. Contractor Report.

    Science.gov (United States)

    Jones, Calvin; And Others

    This data file user's manual documents the procedures used to collect and process high school transcripts for a large sample of the younger cohort (1980 sophomores) in the High School and Beyond survey. The manual provides the user with the technical assistance needed to use the computer file and also discusses the following: (1) sample design for…

  19. Entrepreneurial Orientation and Internationalisation

    DEFF Research Database (Denmark)

    Decker, Arnim; Rollnik-Sadowska, Ewa; Servais, Per

    Entrepreneurial orientation is a multidimensional construct that determines the strategic posture of a firm. In this study we investigate a sample of six manufacturing firms which are located both in a remote area and in a transition economy. Through interpreting the construct of entrepreneurial...... orientation as an attitude held by principals we investigate how entrepreneurial orientation affected the behaviour of these firms, specifically in terms of their internationalisation. Despite the fact that all firms have identical roots we find that entrepreneurial orientation held by their principals affect...

  20. Manual praxis in stone tool manufacture: implications for language evolution.

    Science.gov (United States)

    Ruck, Lana

    2014-12-01

    Alternative functions of the left-hemisphere dominant Broca's region have induced hypotheses regarding the evolutionary parallels between manual praxis and language in humans. Many recent studies on Broca's area reveal several assumptions about the cognitive mechanisms that underlie both functions, including: (1) an accurate, finely controlled body schema, (2) increasing syntactical abilities, particularly for goal-oriented actions, and (3) bilaterality and fronto-parietal connectivity. Although these characteristics are supported by experimental paradigms, many researchers have failed to acknowledge a major line of evidence for the evolutionary development of these traits: stone tools. The neuroscience of stone tool manufacture is a viable proxy for understanding evolutionary aspects of manual praxis and language, and may provide key information for evaluating competing hypotheses on the co-evolution of these cognitive domains in our species. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Incremental Interactive Verification of the Correctness of Object-Oriented Software

    DEFF Research Database (Denmark)

    Mehnert, Hannes

    Development of correct object-oriented software is difficult, in particular if a formalised proof of its correctness is demanded. A lot of current software is developed using the object-oriented programming paradigm. This paradigm compensated for safety and security issues with imperative...... structure. For efficiency, our implementation uses copy-on-write and shared mutable data, not observable by a client. I further use this data structure to verify the correctness of a solution to the point location problem. The results demonstrate that I am able to verify the correctness of object-oriented...... programming, such as manual memory management. Popularly used integrated development environments (IDEs) provide features such as debugging and unit testing to facilitate development of robust software, but hardly any development environment supports the development of provable correct software. A tight...

  2. A system for deduction-based formal verification of workflow-oriented software models

    Directory of Open Access Journals (Sweden)

    Klimek Radosław

    2014-12-01

    Full Text Available The work concerns formal verification of workflow-oriented software models using the deductive approach. The formal correctness of a model’s behaviour is considered. Manually building logical specifications, which are regarded as a set of temporal logic formulas, seems to be a significant obstacle for an inexperienced user when applying the deductive approach. A system, along with its architecture, for deduction-based verification of workflow-oriented models is proposed. The process inference is based on the semantic tableaux method, which has some advantages when compared with traditional deduction strategies. The algorithm for automatic generation of logical specifications is proposed. The generation procedure is based on predefined workflow patterns for BPMN, which is a standard and dominant notation for the modeling of business processes. The main idea behind the approach is to consider patterns, defined in terms of temporal logic, as a kind of (logical primitives which enable the transformation of models to temporal logic formulas constituting a logical specification. Automation of the generation process is crucial for bridging the gap between the intuitiveness of deductive reasoning and the difficulty of its practical application when logical specifications are built manually. This approach has gone some way towards supporting, hopefully enhancing, our understanding of deduction-based formal verification of workflow-oriented models.

  3. Buried Waste Program (BWP) data qualification manual

    International Nuclear Information System (INIS)

    Casey, C.; Larson, R.A.; Harris, G.A.

    1989-06-01

    The Data Qualification Manual (DQM) has been developed to discuss the process required to qualify data generated for the Buried Waste Program (BWP). The data from the BWP tasks conducted at the Radioactive Waste Management Complex (RWMC) and elsewhere will lead to remedial decisions being made which are governed by federal regulations administered by the Environmental Protection Agency (EPA). Data qualification is the process of insuring that only data of planned and known qualities are used to make a decision or answer a question. Although it is the Data Integrity Review Committee's (DIRC) responsibility to insure that the quality of all BWP data is ultimately verified and validated, all personnel who participate in the data gathering process will affect the quality of the data and must be responsible for knowing what is required to produce data of the planned quality. Therefore this manual is addressed to all participants in a data-gathering task. This manual discusses requirements to support data qualification in several areas, including: the sampling and analysis plan; data quality objectives and PARCC goals; sample custody documentation; quality assurance; assembly of the data qualification package; and existing data. 23 refs., 4 figs., 6 tabs

  4. Field manual for ground water reconnaissance. Savannah River Laboratory National Uranium Resource Evaluation Program

    International Nuclear Information System (INIS)

    Ferguson, R.B.; Price, V.; Baucom, E.I.

    1977-01-01

    A manual is presented that is intended to direct and coordinate field operations, site selection, groundwater sample collection, and information codes for the Savannah River Laboratory (SRL) contribution to the National Uranium Resource Evaluation (NURE) program. The manual provides public relations information for field sampling teams as well as technical direction

  5. Manual of selected physico-chemical analytical methods. IV

    International Nuclear Information System (INIS)

    Beran, M.; Klosova, E.; Krtil, J.; Sus, F.; Kuvik, V.; Vrbova, L.; Hamplova, M.; Lengyel, J.; Kelnar, L.; Zakouril, K.

    1990-11-01

    The Central Testing Laboratory of the Nuclear Research Institute at Rez has for a decade been participating in the development of analytical procedures and has been providing analyses of samples of different types and origin. The analytical procedures developed have been published in special journals and a number of them in the Manuals of analytical methods, in three parts. The 4th part of the Manual contains selected physico-chemical methods developed or modified by the Laboratory in the years 1986-1990 within the project ''Development of physico-chemical analytical methods''. In most cases, techniques are involved for non-nuclear applications. Some can find wider applications, especially in analyses of environmental samples. Others have been developed for specific cases of sample analyses or require special instrumentation (mass spectrometer), which partly restricts their applicability by other institutions. (author)

  6. Zooplankton Methodology, Collection & identyification - A field manual

    Digital Repository Service at National Institute of Oceanography (India)

    Goswami, S.C.

    and productivity would largely depend upon the use of correct methodology which involves collection of samples, fixation, preservation, analysis and computation of data. The detailed procedures on all these aspects are given in this manual....

  7. The environmental survey manual: Appendix D

    International Nuclear Information System (INIS)

    1987-08-01

    The purpose of this manual is to provide guidance to the Survey and Sampling and Analysis teams that conduct the one-time Environmental Survey of the major US Department of Energy operating facilities. This appendix contains procedures for chemical analysis of organics, inorganics, and radioisotopes

  8. Real-Time Multiprocessor Programming Language (RTMPL) user's manual

    Science.gov (United States)

    Arpasi, D. J.

    1985-01-01

    A real-time multiprocessor programming language (RTMPL) has been developed to provide for high-order programming of real-time simulations on systems of distributed computers. RTMPL is a structured, engineering-oriented language. The RTMPL utility supports a variety of multiprocessor configurations and types by generating assembly language programs according to user-specified targeting information. Many programming functions are assumed by the utility (e.g., data transfer and scaling) to reduce the programming chore. This manual describes RTMPL from a user's viewpoint. Source generation, applications, utility operation, and utility output are detailed. An example simulation is generated to illustrate many RTMPL features.

  9. Field manual for reclamation of salt contaminated soils

    International Nuclear Information System (INIS)

    Burley, M.J.; Lesky, M.; Warren, R.J.

    1988-01-01

    Saltwater is often produced with crude oil and must be separated from it at a processing facility prior to deep-well injection. Increasing volumes of saltwater have led to pipeline corrosion and an increasing frequency of saltwater spills. A field manual for treating saltwater-contaminated soil was prepared by the Production Research Department of Esso Resources Canada Limited and Husky Oil Operations Limited. The purpose of the manual is to provide field and plant operations with a practical guide for reclaiming brine spills on mineral (agricultural) soil. The manual covers background scientific theory about how saltwater affects the soil, initial steps for treating new spills, site assessment, and reclamation program design, implementation and monitoring. A sample spill site assessment form is included. 8 refs

  10. Data acquisition for X ray microprobe. User's manual

    International Nuclear Information System (INIS)

    2002-01-01

    A modified data acquisition software for X ray microprobe was developed by the Physics Group, Instrumentation Unit, IAEA Laboratories at Seibersdorf, with assistance from M. Bogovac, Croatia. The software consists of data acquisition (scanning and calibration), automatic positioning and micro-movement of sample, data reduction and evaluation. The acquisition software was designed in order to support different measurement set-ups which are applied in low-energy nuclear physics. The modification was done in 1999-2000 under the projects Nuclear Spectrometry and Utilization of Particle Accelerators. The manual supersedes the first version entitled Microanalysis Data Acquisition and Control Program published under Computer Manual Series, No. 9 in 1996. The software described in this manual is freely available from the IAEA upon request

  11. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis.

    Science.gov (United States)

    İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman

    2016-08-01

    Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.

  12. Automatic short axis orientation of the left ventricle in 3D ultrasound recordings

    Science.gov (United States)

    Pedrosa, João.; Heyde, Brecht; Heeren, Laurens; Engvall, Jan; Zamorano, Jose; Papachristidis, Alexandros; Edvardsen, Thor; Claus, Piet; D'hooge, Jan

    2016-04-01

    The recent advent of three-dimensional echocardiography has led to an increased interest from the scientific community in left ventricle segmentation frameworks for cardiac volume and function assessment. An automatic orientation of the segmented left ventricular mesh is an important step to obtain a point-to-point correspondence between the mesh and the cardiac anatomy. Furthermore, this would allow for an automatic division of the left ventricle into the standard 17 segments and, thus, fully automatic per-segment analysis, e.g. regional strain assessment. In this work, a method for fully automatic short axis orientation of the segmented left ventricle is presented. The proposed framework aims at detecting the inferior right ventricular insertion point. 211 three-dimensional echocardiographic images were used to validate this framework by comparison to manual annotation of the inferior right ventricular insertion point. A mean unsigned error of 8, 05° +/- 18, 50° was found, whereas the mean signed error was 1, 09°. Large deviations between the manual and automatic annotations (> 30°) only occurred in 3, 79% of cases. The average computation time was 666ms in a non-optimized MATLAB environment, which potentiates real-time application. In conclusion, a successful automatic real-time method for orientation of the segmented left ventricle is proposed.

  13. Effect of the sample annealing temperature and sample crystallographic orientation on the charge kinetics of MgO single crystals subjected to keV electron irradiation.

    Science.gov (United States)

    Boughariou, A; Damamme, G; Kallel, A

    2015-04-01

    This paper focuses on the effect of sample annealing temperature and crystallographic orientation on the secondary electron yield of MgO during charging by a defocused electron beam irradiation. The experimental results show that there are two regimes during the charging process that are better identified by plotting the logarithm of the secondary electron emission yield, lnσ, as function of the total trapped charge in the material QT. The impact of the annealing temperature and crystallographic orientation on the evolution of lnσ is presented here. The slope of the asymptotic regime of the curve lnσ as function of QT, expressed in cm(2) per trapped charge, is probably linked to the elementary cross section of electron-hole recombination, σhole, which controls the trapping evolution in the reach of the stationary flow regime. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  14. Manual Therapy

    OpenAIRE

    Hakgüder, Aral; Kokino, Siranuş

    2002-01-01

    Manual therapy has been used in the treatment of pain and dysfunction of spinal and peripheral joints for more than a hundred years. Manual medicine includes manipulation, mobilization, and postisometric relaxation techniques. The aim of manual therapy is to enhance restricted movement caused by blockage of joints keeping postural balance, restore function and maintain optimal body mechanics. Anatomic, biomechanical, and neurophysiological evaluations of the leucomotor system is essential for...

  15. Design/CPN. A Reference Manual

    DEFF Research Database (Denmark)

    Jensen et. al, Kurt

    /CPN WWW pages. To speed up the access to the Design/CPN manuals we recommend to keep a local copy - which may be shared by all users in your organisation. In this way you do not need to go via our WWW server each time you need to look in a manual. For some of the largest manuals, we also supply files......Note: The manuals are available as PDF files . There are two sets of manuals - one for the Unix platform and another for the Mac platform. Each set of manual consists of: Tutorial (for the Design/CPN editor and simulator) Reference Manual (for the Design/CPN editor and simulator) Programmer......'s Manual (with Design/OA functions and Charts) Occurrence Graph Manual (integrated tutorial and reference manual) OE/OS Graph Manual (integrated tutorial and reference manual) Other Manuals (e.g. a short overview of CPN ML).   The Tutorial, Reference Manual and Programmer's Manual are made for Design...

  16. Caltrans : construction manual

    Science.gov (United States)

    2009-08-01

    Caltrans intends this manual as a resource for all personnel engaged in contract administration. The manual establishes policies and procedures for the construction phase of Caltrans projects. However, this manual is not a contract document. It impos...

  17. Optimal grade control sampling practice in open-pit mining

    DEFF Research Database (Denmark)

    Engström, Karin; Esbensen, Kim Harry

    2017-01-01

    Misclassification of ore grades results in lost revenues, and the need for representative sampling procedures in open pit mining is increasingly important in all mining industries. This study evaluated possible improvements in sampling representativity with the use of Reverse Circulation (RC) drill...... sampling compared to manual Blast Hole (BH) sampling in the Leveäniemi open pit mine, northern Sweden. The variographic experiment results showed that sampling variability was lower for RC than for BH sampling. However, the total costs for RC drill sampling are significantly exceeding current costs...... for manual BH sampling, which needs to be compensated for by other benefits to motivate introduction of RC drilling. The main conclusion is that manual BH sampling can be fit-for-purpose in the studied open pit mine. However, with so many mineral commodities and mining methods in use globally...

  18. Physical Therapy and Manual Physical Therapy: Differences in Patient Characteristics.

    NARCIS (Netherlands)

    van Ravensberg, C. D. Dorine; Oostendorp, Rob A B; van Berkel, Lonneke M.; Scholten-Peeters, Gwendolijne G M; Pool, Jan J.M.; Swinkels, Raymond A. H. M.; Huijbregts, Peter A.

    2005-01-01

    This study compared socio-demographic characteristics, health problem characteristics, and primary process data between database samples of patients referred to physical therapy (PT) versus a sample of patients referred to manual physical therapy (MPT) in the Netherlands. Statistical analysis

  19. Physical therapy and manual physical therapy: Differences in patient characteristics

    NARCIS (Netherlands)

    van Ravensberg, C. D. Dorine; Oostendorp, R.A.B.; van Berkel, Lonneke M.; Scholten-Peeters, G.G.M.; Pool, J.J.M.; Swinkels, Raymond A. H. M.; Huijbregts, Peter A.

    2005-01-01

    This study compared socio-demographic characteristics, health problem characteristics, and primary process data between database samples of patients referred to physical therapy (PT) versus a sample of patients referred to manual physical therapy (MPT) in the Netherlands. Statistical analysis

  20. Physical Therapy and Manual Physical Therapy: Differences in Patient Characteristics

    NARCIS (Netherlands)

    van Ravensberg, C. D. Dorine; Oostendorp, Rob A B; van Berkel, Lonneke M.; Scholten-Peeters, Gwendolijne G. M.; Pool, Jan J.M.; Swinkels, Raymond A. H. M.; Huijbregts, Peter A.

    2005-01-01

    This study compared socio-demographic characteristics, health problem characteristics, and primary process data between database samples of patients referred to physical therapy (PT) versus a sample of patients referred to manual physical therapy (MPT) in the Netherlands. Statistical analysis

  1. Radioanalytical methods manual

    International Nuclear Information System (INIS)

    Chiu, N.W.; Dean, J.R.

    1986-01-01

    This Radioanalytical Methods manual is comprised of 12 chapters. It includes a review of the pertinent literature up to the end of 1982 pertaining to the measurement of the radioactive species listed under the terms of the contract. Included is methodology recommended for the decompositions of soils, tailings, ores, biological samples and air filters. Detailed analytical methodology for the measurement of gross alpha, gross beta, gross gamma, uranium, radium-226, radium-228, lead-210, thorium-232, thorium-230, thorium-228, total thorium, radon-222, radon-220 and radon-219 is presented

  2. Anisotropic effects in a powder oriented YBCO sample using a three axes magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Boudissa, M. [Universite Ferhat Abbas, Faculte des Sciences de l' Ingenieur, Setif (Algeria); Halimi, R. [Universite Mentouri, Unite de Recherche de Physique des Materiaux, Constantine (Algeria); Senoussi, S. [Universite Paris-Sud, Laboratoire de Physique des Solides, Orsay (France)

    2006-09-15

    To measure the components of the magnetization vector along the XYZ directions of a reference frame, in the superconducting materials, we have conceived a three axes magnetometer, with a detection system equipped with three series of pick-up coils with axes parallel to the three directions X,Y, and Z. We describe in this paper the details of the design and the method of measurement, with some results obtained by magnetic measurements on samples of oriented YBCO powder, with size of the grains between 20 {mu}m and 40 {mu}m, for values of the angle {theta} between the magnetic field H and the c-axis, between 0 and 90 and for values of fields up to 12 T. The direct measurement of the Z and the XY components of the irreversible magnetization vector, M{sub irr}, allowed us to observe the twin effect (channeling) on the vortex pinning observed by many authors, the evolution of the magnetization vector and to measure with a high accuracy the anisotropy factor of our samples. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  3. Anisotropic effects in a powder oriented YBCO sample using a three axes magnetometer

    International Nuclear Information System (INIS)

    Boudissa, M.; Halimi, R.; Senoussi, S.

    2006-01-01

    To measure the components of the magnetization vector along the XYZ directions of a reference frame, in the superconducting materials, we have conceived a three axes magnetometer, with a detection system equipped with three series of pick-up coils with axes parallel to the three directions X,Y, and Z. We describe in this paper the details of the design and the method of measurement, with some results obtained by magnetic measurements on samples of oriented YBCO powder, with size of the grains between 20 μm and 40 μm, for values of the angle θ between the magnetic field H and the c-axis, between 0 and 90 and for values of fields up to 12 T. The direct measurement of the Z and the XY components of the irreversible magnetization vector, M irr , allowed us to observe the twin effect (channeling) on the vortex pinning observed by many authors, the evolution of the magnetization vector and to measure with a high accuracy the anisotropy factor of our samples. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  4. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    Directory of Open Access Journals (Sweden)

    Fatma Demet Ä°nce

    2016-08-01

    Full Text Available Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA, Dirui FUS-200 (DIRUI Industrial Co., China automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient and the rates within the same grading were evaluated. Results: For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. Conclusion: The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization. Keywords: Urinalysis, Autoanalysis, Microscopy

  5. Organizing for Customer and Competitor Orientation

    DEFF Research Database (Denmark)

    Sørensen, Hans Eibe; Slater, Stanley F.

    2007-01-01

    The purpose of this study is to investigate the role of structural liaison devices, specialization, the presence of a marketing function, and competitive intensity as antecedents to firms' customer and competitor orientation. Results based on a sample of 99 medium-sized (50-250 employees......) manufacturing firms indicate, that while specialization and liaison devices facilitate customer orientation only liaison devices facilitate competitor orientation. Competitive intensity has no effects on customer orientation but influence competitor orientation. The results also indicate that the presence...... of a marketing function has no influence on the level of firms' customer and competitor orientation....

  6. CSTEM User Manual

    Science.gov (United States)

    Hartle, M.; McKnight, R. L.

    2000-01-01

    This manual is a combination of a user manual, theory manual, and programmer manual. The reader is assumed to have some previous exposure to the finite element method. This manual is written with the idea that the CSTEM (Coupled Structural Thermal Electromagnetic-Computer Code) user needs to have a basic understanding of what the code is actually doing in order to properly use the code. For that reason, the underlying theory and methods used in the code are described to a basic level of detail. The manual gives an overview of the CSTEM code: how the code came into existence, a basic description of what the code does, and the order in which it happens (a flowchart). Appendices provide a listing and very brief description of every file used by the CSTEM code, including the type of file it is, what routine regularly accesses the file, and what routine opens the file, as well as special features included in CSTEM.

  7. Directional dependency of air sampling

    International Nuclear Information System (INIS)

    1994-01-01

    A field study was performed by Idaho State University-Environmental Monitoring Laboratory (EML) to examine the directional dependency of low-volume air samplers. A typical continuous low volume air sampler contains a sample head that is mounted on the sampler housing either horizontally through one of four walls or vertically on an exterior wall 'looking down or up.' In 1992, a field study was undertaken to estimate sampling error and to detect the directional effect of sampler head orientation. Approximately 1/2 mile downwind from a phosphate plant (continuous source of alpha activity), four samplers were positioned in identical orientation alongside one sampler configured with the sample head 'looking down'. At least five consecutive weekly samples were collected. The alpha activity, beta activity, and the Be-7 activity collected on the particulate filter were analyzed to determine sampling error. Four sample heads were than oriented to the four different horizontal directions. Samples were collected for at least five weeks. Analysis of the alpha data can show the effect of sampler orientation to a know near source term. Analysis of the beta and Be-7 activity shows the effect of sampler orientation to a ubiquitous source term

  8. Predictors of "New Economy" Career Orientation in an Australian Sample of Late Adolescents

    Science.gov (United States)

    Creed, Peter; Macpherson, Jennifer; Hood, Michelle

    2011-01-01

    The authors surveyed 207 late adolescents on measures of new economy career orientation (protean and boundaryless career orientation), career adaptability (planning, self-exploration, environmental exploration, decision making, and self-regulation), disposition (proactive disposition), and environmental support (social support) and hypothesized…

  9. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-06-18

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  10. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-03-25

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  11. Load research manual. Volume 1. Load research procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  12. SYVAC3 manual

    International Nuclear Information System (INIS)

    Andres, T.H.

    2000-01-01

    SYVAC3 (Systems Variability Analysis Code, generation 3) is a computer program that implements a method called systems variability analysis to analyze the behaviour of a system in the presence of uncertainty. This method is based on simulating the system many times to determine the variation in behaviour it can exhibit. SYVAC3 specializes in systems representing the transport of contaminants, and has several features to simplify the modelling of such systems. It provides a general tool for estimating environmental impacts from the dispersal of contaminants. This report describes the use and structure of SYVAC3. It is intended for modellers, programmers, operators and reviewers who deal with simulation codes based on SYVAC3. From this manual they can learn how to link a model with SYVAC3, how to set up an input file, and how to extract results from output files. The manual lists the subroutines of SYVAC3 that are available for use by models, and describes their argument lists. It also gives an overview of how routines in the File Reading Package, the Parameter Sampling Package and the Time Series Package can be used by programs outside of SYVAC3. (author)

  13. SYVAC3 manual

    Energy Technology Data Exchange (ETDEWEB)

    Andres, T.H

    2000-07-01

    SYVAC3 (Systems Variability Analysis Code, generation 3) is a computer program that implements a method called systems variability analysis to analyze the behaviour of a system in the presence of uncertainty. This method is based on simulating the system many times to determine the variation in behaviour it can exhibit. SYVAC3 specializes in systems representing the transport of contaminants, and has several features to simplify the modelling of such systems. It provides a general tool for estimating environmental impacts from the dispersal of contaminants. This report describes the use and structure of SYVAC3. It is intended for modellers, programmers, operators and reviewers who deal with simulation codes based on SYVAC3. From this manual they can learn how to link a model with SYVAC3, how to set up an input file, and how to extract results from output files. The manual lists the subroutines of SYVAC3 that are available for use by models, and describes their argument lists. It also gives an overview of how routines in the File Reading Package, the Parameter Sampling Package and the Time Series Package can be used by programs outside of SYVAC3. (author)

  14. Main-coolant-pump shaft-seal guidelines. Volume 1. Maintenance-manual guidelines. Final report

    International Nuclear Information System (INIS)

    Fair, C.E.; Greer, A.O.

    1983-03-01

    This report presents a set of guidelines and a listing of information and data which should be included in maintenance manuals and procedures for Main Coolant Pump Shaft Seals. The noted guidelines and data listing are developed from EPRI sponsored nuclear plant seal operating experience studies. The maintenance oriented results of the most recent such study is summarized. The shaft seal and its auxiliary supporting systems are discussed from both technical and maintenance related viewpoints

  15. INTRA/Mod3.2. Manual and code description. Volume 2 - User's manual

    International Nuclear Information System (INIS)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User's Manual is an input description. This document, the User's Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  16. CytoSpectre: a tool for spectral analysis of oriented structures on cellular and subcellular levels.

    Science.gov (United States)

    Kartasalo, Kimmo; Pölönen, Risto-Pekka; Ojala, Marisa; Rasku, Jyrki; Lekkala, Jukka; Aalto-Setälä, Katriina; Kallio, Pasi

    2015-10-26

    Orientation and the degree of isotropy are important in many biological systems such as the sarcomeres of cardiomyocytes and other fibrillar structures of the cytoskeleton. Image based analysis of such structures is often limited to qualitative evaluation by human experts, hampering the throughput, repeatability and reliability of the analyses. Software tools are not readily available for this purpose and the existing methods typically rely at least partly on manual operation. We developed CytoSpectre, an automated tool based on spectral analysis, allowing the quantification of orientation and also size distributions of structures in microscopy images. CytoSpectre utilizes the Fourier transform to estimate the power spectrum of an image and based on the spectrum, computes parameter values describing, among others, the mean orientation, isotropy and size of target structures. The analysis can be further tuned to focus on targets of particular size at cellular or subcellular scales. The software can be operated via a graphical user interface without any programming expertise. We analyzed the performance of CytoSpectre by extensive simulations using artificial images, by benchmarking against FibrilTool and by comparisons with manual measurements performed for real images by a panel of human experts. The software was found to be tolerant against noise and blurring and superior to FibrilTool when analyzing realistic targets with degraded image quality. The analysis of real images indicated general good agreement between computational and manual results while also revealing notable expert-to-expert variation. Moreover, the experiment showed that CytoSpectre can handle images obtained of different cell types using different microscopy techniques. Finally, we studied the effect of mechanical stretching on cardiomyocytes to demonstrate the software in an actual experiment and observed changes in cellular orientation in response to stretching. CytoSpectre, a versatile, easy

  17. Structures manual

    Science.gov (United States)

    2001-01-01

    This manual was written as a guide for use by design personnel in the Vermont Agency of Transportation Structures Section. This manual covers the design responsibilities of the Section. It does not cover other functions that are a part of the Structu...

  18. Ciencias 2. Manual do Professor (Science Teacher's Manual).

    Science.gov (United States)

    Raposo, Lucilia

    This is the teacher's manual for Ciencias 2, the second in a series of elementary science textbooks for Portuguese-speaking students. The student textbook contains 10 chapters and 57 activities. The teacher's manual presents an explanation of the educational goals and the organization of the content, Topics included are environment, the human,…

  19. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  20. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  1. Egyptian Mythological Manuals

    DEFF Research Database (Denmark)

    Jørgensen, Jens Kristoffer Blach

    From the hands of Greek mythographers a great number of myths have survived along with philosophical discussions of their meaning and relevance for the Greeks. It is little known that something similar existed in ancient Egypt where temple libraries and archives held scholarly literature used...... by the native priesthood, much of which has only been published in recent years. As part of this corpus of texts, the ancient Egyptian mythological manuals offer a unique perspective on how the Egyptian priesthood structured and interpreted Egyptian myths. The thesis looks at the different interpretative...... techniques used in the Tebtunis Mythological Manual (Second century CE) and the Mythological Manual of the Delta (Sixth century BCE) and the place of these manuals within the larger corpus of priestly scholarly literature from ancient Egypt. To organize the wealth of local myths the manuals use model...

  2. Annual Net Ecosystem Productivity of Wetlands: A Comparison of Automated and Manual Chamber Methods

    Science.gov (United States)

    Burrows, E. H.; Bubier, J. L.; Mosedale, A.; Crill, P. M.

    2001-05-01

    Net Ecosystem Exchange (NEE) of carbon dioxide (CO2) was measured in a minerotrophic poor fen in southeastern New Hampshire during the 2000 growing season using two types of chamber methods. Instantaneous CO2 flux was measured with transparent lexan and teflon static climate controlled chambers by calculating the change in headspace CO2 concentration in the chamber over time. Once per week the flux was sampled from ten manually operated chambers using a LI-COR 6200 portable photosynthesis system, which included a LI-6250 infrared gas analyzer, connected to the chambers. Ten automated chambers were installed in May of 2000, sampling CO2 flux every three hours over the diurnal cycle using a LI-COR 6262 infrared gas analyzer. The chambers and collars were placed throughout the fen in order to sample the range of plant communities. The manual sampling was done during the middle of the day, but the rate of photosynthesis changes depending on the amount of photosynthetically active radiation (PAR). In order to simulate varying light levels, shrouds blocking different amounts of light were placed over each manual chamber. An opaque shroud was used to measure respiration. NEE ranged from -13.0 to 12.5 μ mol CO2/m2/s in the manual chambers and -16.2 to 11.8 μ mol CO2/m2/s in the automated chambers for the mid-summer growing season. Manual respiration fluxes were measured under higher temperature regimes and the response of respiration to temperature will be factored in when comparing the two chamber techniques. Research during the summer of 2001 will also include diurnal measurements. Growing season net ecosystem productivity (NEP) will be estimated and compared for the two chamber systems. Several models will be used to estimate the flux when the manual chambers were not being sampled. The models will be based on biomass and dominant species in each chamber, and various environmental factors including water table, pH, relative humidity, PAR, air and peat temperature

  3. Towards 3D crystal orientation reconstruction using automated crystal orientation mapping transmission electron microscopy (ACOM-TEM).

    Science.gov (United States)

    Kobler, Aaron; Kübel, Christian

    2018-01-01

    To relate the internal structure of a volume (crystallite and phase boundaries) to properties (electrical, magnetic, mechanical, thermal), a full 3D reconstruction in combination with in situ testing is desirable. In situ testing allows the crystallographic changes in a material to be followed by tracking and comparing the individual crystals and phases. Standard transmission electron microscopy (TEM) delivers a projection image through the 3D volume of an electron-transparent TEM sample lamella. Only with the help of a dedicated TEM tomography sample holder is an accurate 3D reconstruction of the TEM lamella currently possible. 2D crystal orientation mapping has become a standard method for crystal orientation and phase determination while 3D crystal orientation mapping have been reported only a few times. The combination of in situ testing with 3D crystal orientation mapping remains a challenge in terms of stability and accuracy. Here, we outline a method to 3D reconstruct the crystal orientation from a superimposed diffraction pattern of overlapping crystals without sample tilt. Avoiding the typically required tilt series for 3D reconstruction enables not only faster in situ tests but also opens the possibility for more stable and more accurate in situ mechanical testing. The approach laid out here should serve as an inspiration for further research and does not make a claim to be complete.

  4. Extricating Manual and Non-Manual Features for Subunit Level Medical Sign Modelling in Automatic Sign Language Classification and Recognition.

    Science.gov (United States)

    R, Elakkiya; K, Selvamani

    2017-09-22

    Subunit segmenting and modelling in medical sign language is one of the important studies in linguistic-oriented and vision-based Sign Language Recognition (SLR). Many efforts were made in the precedent to focus the functional subunits from the view of linguistic syllables but the problem is implementing such subunit extraction using syllables is not feasible in real-world computer vision techniques. And also, the present recognition systems are designed in such a way that it can detect the signer dependent actions under restricted and laboratory conditions. This research paper aims at solving these two important issues (1) Subunit extraction and (2) Signer independent action on visual sign language recognition. Subunit extraction involved in the sequential and parallel breakdown of sign gestures without any prior knowledge on syllables and number of subunits. A novel Bayesian Parallel Hidden Markov Model (BPaHMM) is introduced for subunit extraction to combine the features of manual and non-manual parameters to yield better results in classification and recognition of signs. Signer independent action aims in using a single web camera for different signer behaviour patterns and for cross-signer validation. Experimental results have proved that the proposed signer independent subunit level modelling for sign language classification and recognition has shown improvement and variations when compared with other existing works.

  5. FAMily-Oriented Support (FAMOS)

    DEFF Research Database (Denmark)

    Salem, Hanin; Johansen, Christoffer; Schmiegelow, Kjeld

    2017-01-01

    BACKGROUND: We developed and tested the feasibility of a manualized psychosocial intervention, FAMily-Oriented Support (FAMOS), a home-based psychosocial intervention for families of childhood cancer survivors. The aim of the intervention is to support families in adopting healthy strategies...... to cope with the psychological consequences of childhood cancer. The intervention is now being evaluated in a nationwide randomized controlled trial (RCT). METHODS AND DESIGN: FAMOS is based on principles of family systems therapy and cognitive behavioral therapy, and is delivered in six sessions at home...... satisfaction with the format, timing, and content of the intervention. CONCLUSION: The results indicate that the FAMOS intervention is feasible in terms of recruitment, retention, and acceptability. The effects of the intervention on post-traumatic stress, depression, anxiety, family functioning, and quality...

  6. A comparison of automated and manual radioimmunoassays for the estimation of serum digoxin

    International Nuclear Information System (INIS)

    Tuttlebee, J.W.

    1984-01-01

    Digoxin was assayed manually (SPAC kit) and by an automated radioimmunoassay instrument (ARIA II). There was good correlation between the methods (r=0.964; n=120). Carryover by the automated method was marginally significant from low to high level samples (5.2%), but insignificant from high to low level samples (1.4%). The precision on the ARIA II was far better in spite of the fact that assays were performed only in singlets compared with duplicates on the manual procedure. Best precision was obtained at the high level (3.76 nmol/l; between-batch CV: 2.4% ARIA; 5.5% SPAC). All values for control samples (manual and automated) fell within 6% of the all-method means. Using the ARIA II is marginally quicker and significantly cheaper. However, some back-up procedure is required for 'down time' with the machine, for what can be an urgent investigation. Patient results correlated well with clinical data. (orig.) [de

  7. Environmental Measurements Laboratory (EML) procedures manual

    International Nuclear Information System (INIS)

    Chieco, N.A.; Bogen, D.C.; Knutson, E.O.

    1990-11-01

    Volume 1 of this manual documents the procedures and existing technology that are currently used by the Environmental Measurements Laboratory. A section devoted to quality assurance has been included. These procedures have been updated and revised and new procedures have been added. They include: sampling; radiation measurements; analytical chemistry; radionuclide data; special facilities; and specifications. 228 refs., 62 figs., 37 tabs. (FL)

  8. Impact of Oriented Clay Particles on X-Ray Spectroscopy Analysis

    Science.gov (United States)

    Lim, A. J. M. S.; Syazwani, R. N.; Wijeyesekera, D. C.

    2016-07-01

    Understanding the engineering properties of the mineralogy and microfabic of clayey soils is very complex and thus very difficult for soil characterization. Micromechanics of soils recognize that the micro structure and mineralogy of clay have a significant influence on its engineering behaviour. To achieve a more reliable quantitative evaluation of clay mineralogy, a proper sample preparation technique for quantitative clay mineral analysis is necessary. This paper presents the quantitative evaluation of elemental analysis and chemical characterization of oriented and random oriented clay particles using X-ray spectroscopy. Three different types of clays namely marine clay, bentonite and kaolin clay were studied. The oriented samples were prepared by placing the dispersed clay in water and left to settle on porous ceramic tiles by applying a relatively weak suction through a vacuum pump. Images form a Scanning Electron Microscope (SEM) was also used to show the comparison between the orientation patterns of both the sample preparation techniques. From the quantitative analysis of the X-ray spectroscopy, oriented sampling method showed more accuracy in identifying mineral deposits, because it produced better peak intensity on the spectrum and more mineral content can be identified compared to randomly oriented samples.

  9. Effects of Cold Rolling Reduction and Initial Goss Grains Orientation on Texture Evolution and Magnetic Performance of Ultra-thin Grain-oriented Silicon Steel

    Directory of Open Access Journals (Sweden)

    LIANG Rui-yang

    2017-06-01

    Full Text Available The ultra-thin grain-oriented silicon steel strips with a thickness of 0.06-0.12mm were produced by one-step-rolling methods with different Goss-orientation of grain-oriented silicon steel sheets. The effect of cold rolling reduction and initial Goss-orientation of samples on texture evolution and magnetic performance of ultra-thin grain-oriented silicon steel strips was studied by EBSD. The result shows that with the increase of cold rolling reduction and decrease of strips thickness, the recrystallization texture is enhanced after annealing.When the cold rolling reduction is 70%,RD//〈001〉 recrystallization texture is the sharpest, and the magnetic performance is the best. The higher degree of Goss orientation in initial sample is, the better magnetic performance of ultra-thin grain-oriented silicon steel.Therefore, for producing an ultra-thin grain-oriented silicon steel with high performance, a material with a concentrated orientation of Goss grains can be used.

  10. Patterns of Wildlife Value Orientations

    Science.gov (United States)

    Harry C. Zinn; Michael J. Manfredo; Susan C. Barro

    2002-01-01

    Public value orientations toward wildlife may be growing less utilitarian and more protectionist. To better understand one aspect of this trend, we investigated patterns of wildlife value orientations within families. Using a mail survey, we sampled Pennsylvania and Colorado hunting license holders 50 or older; obtaining a 54% response rate (n = 599). Males (94% of...

  11. NJOY nuclear data processing system: user's manual

    International Nuclear Information System (INIS)

    MacFarlane, R.E.; Barrett, R.J.; Muir, D.W.; Boicourt, R.M.

    1978-12-01

    The NJOY nuclear data processing system is a comprehensive computer code package for producing cross sections for neutron and photon transport calculations from ENDF/B-IV and -V evaluated nuclear data. This user's manual provides a concise description of the code, input instructions, sample problems, and installation instructions. 1 figure, 3 tables

  12. Validation of the Sexual Orientation Microaggression Inventory in Two Diverse Samples of LGBTQ Youth.

    Science.gov (United States)

    Swann, Gregory; Minshew, Reese; Newcomb, Michael E; Mustanski, Brian

    2016-08-01

    Critical race theory asserts that microaggressions, or low-level, covert acts of aggression, are commonplace in the lives of people of color. These theorists also assert a taxonomy of microaggressions, which includes "microassaults," "microinsults," and "microinvalidations". The theory of microaggressions has been adopted by researchers of LGBTQ communities. This study investigated the three-factor taxonomy as it relates to a diverse sample of LGBTQ youth using the newly developed Sexual Orientation Microaggression Inventory (SOMI). Exploratory factor analysis was used to determine the number of factors that exist in SOMI in a sample of 206 LGBTQ-identifying youth. Follow up confirmatory factor analyses were conducted in order to compare single-factor, unrestricted four-factor, second-order, and bi-factor models in a separate sample of 363 young men who have sex with men. The best fitting model was used to predict victimization, depressive symptoms, and depression diagnosis in order to test validity. The best fitting model was a bi-factor model utilizing 19 of the original 26 items with a general factor and four specific factors representing anti-gay attitudes ("microinsults"), denial of homosexuality, heterosexism ("microinvalidations"), and societal disapproval ("microassaults"). Reliability analyses found that the majority of reliable variance was accounted for by the general factor. The general factor was a significant predictor of victimization and depressive symptoms, as well as unrelated to social desirability, suggesting convergent, criterion-related, and discriminant validity. SOMI emerged as a scale with evidence of validity for assessing exposure to microaggressions in a diverse sample of LGBTQ youth.

  13. On the effect of the fiber orientation on the flexural stiffness of injection molded short fiber reinforced polycarbonate plates

    NARCIS (Netherlands)

    Neves, N.M.; Isdell, G.; Pouzada, A.S.; Powell, P.C.

    1998-01-01

    The through-thickness fiber orientation distribution of injection molded polycarbonate plates was experimentally determined by light reflection microscopy and manual digitization of polished cross sections. Fiber length distribution was determined by pyrolysis tests followed by image analysis. A

  14. JacketSE: An Offshore Wind Turbine Jacket Sizing Tool; Theory Manual and Sample Usage with Preliminary Validation

    Energy Technology Data Exchange (ETDEWEB)

    Damiani, Rick [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-02-08

    This manual summarizes the theory and preliminary verifications of the JacketSE module, which is an offshore jacket sizing tool that is part of the Wind-Plant Integrated System Design & Engineering Model toolbox. JacketSE is based on a finite-element formulation and on user-prescribed inputs and design standards' criteria (constraints). The physics are highly simplified, with a primary focus on satisfying ultimate limit states and modal performance requirements. Preliminary validation work included comparing industry data and verification against ANSYS, a commercial finite-element analysis package. The results are encouraging, and future improvements to the code are recommended in this manual.

  15. Effects of manual threshold setting on image analysis results of a sandstone sample structural characterization by X-ray microtomography

    International Nuclear Information System (INIS)

    Moreira, Anderson C.; Fernandes, Celso P.; Fernandes, Jaquiel S.; Marques, Leonardo C.; Appoloni, Carlos R.; Nagata, Rodrigo

    2009-01-01

    X-ray microtomography is a nondestructive nuclear technique widely applied for samples structural characterization. This methodology permits the investigation of materials porous phase, without special sample preparation, generating bidimensional images of the irradiated sample. The images are generated by the linear attenuation coefficient mapping of the sample. In order to do a quantitative characterization, the images have to be binarized, separating porous phase from the material matrix. The choice of the correct threshold in the grey level histogram is an important and discerning procedure for the binary images creation. Slight variations of the threshold level led to substantial variations in physical parameters determination, like porosity and pore size distribution values. The aim of this work is to evaluate these variations based on some manual threshold setting. Employing Imago image analysis software, four operators determined the porosity and pore size distribution of a sandstone sample by image analysis. The microtomography measurements were accomplished with the following scan conditions: 60 kV, 165 μA, 1 mm Al filter, 0.45 deg step size and 180.0 deg total rotation angle with and 3.8 μm and 11 μm spatial resolution. The global average porosity values, determined by the operators, range from 27.8 to 32.4 % for 3.8 μm spatial resolution and 12.3 to 28.3 % for 11 μm spatial resolution. Percentage differences among the pore size distributions were also found. For the same pore size range, 5.5 % and 17.1 %, for 3.8 μm and 11 μm spatial resolutions respectively, were noted. (author)

  16. Programming in an object-oriented environment

    CERN Document Server

    Ege, Raimund K

    1992-01-01

    Programming in an Object-Oriented Environment provides an in-depth look at the concepts behind the technology of object-oriented programming.This book explains why object-oriented programming has the potential to vastly improve the productivity of programmers and how to apply this technology in a practical environment. Many programming examples are included, focusing on how different programming languages support the core of object-oriented concepts. C++ is used as the main sample language throughout this text.This monograph consists of two major parts. Part I provides an introduction to objec

  17. Newborn screening healthcare information system based on service-oriented architecture.

    Science.gov (United States)

    Hsieh, Sung-Huai; Hsieh, Sheau-Ling; Chien, Yin-Hsiu; Weng, Yung-Ching; Hsu, Kai-Ping; Chen, Chi-Huang; Tu, Chien-Ming; Wang, Zhenyu; Lai, Feipei

    2010-08-01

    In this paper, we established a newborn screening system under the HL7/Web Services frameworks. We rebuilt the NTUH Newborn Screening Laboratory's original standalone architecture, having various heterogeneous systems operating individually, and restructured it into a Service-Oriented Architecture (SOA), distributed platform for further integrity and enhancements of sample collections, testing, diagnoses, evaluations, treatments or follow-up services, screening database management, as well as collaboration, communication among hospitals; decision supports and improving screening accuracy over the Taiwan neonatal systems are also addressed. In addition, the new system not only integrates the newborn screening procedures among phlebotomy clinics, referral hospitals, as well as the newborn screening center in Taiwan, but also introduces new models of screening procedures for the associated, medical practitioners. Furthermore, it reduces the burden of manual operations, especially the reporting services, those were heavily dependent upon previously. The new system can accelerate the whole procedures effectively and efficiently. It improves the accuracy and the reliability of the screening by ensuring the quality control during the processing as well.

  18. ASSERT-4 user's manual

    International Nuclear Information System (INIS)

    Judd, R.A.; Tahir, A.; Carver, M.B.; Stewart, D.G.; Thibeault, P.R.; Rowe, D.S.

    1984-09-01

    ASSERT-4 is an advanced subchannel code being developed primarily to model single- and two-phase flow and heat transfer in horizontal rod bundles. This manual is intended to facilitate the application of this code to the analysis of flow in reactor fuel channels. It contains a brief description of the thermalhydraulic model and ASSERT-4 solution scheme, and other information required by users. This other information includes a detailed discussion of input data requirements, a sample problem and solution, and information describing how to access and run ASSERT-4 on the Chalk River computers

  19. The design process of a reading comprehension manual

    Directory of Open Access Journals (Sweden)

    Sergio Alonso Lopera Medina

    2015-05-01

    Full Text Available Material design is an important part in the teaching practices. This article describes the process of material design of a foreign language (FL reading manual for undergraduate students at Universidad de Antioquia (Medellín – Colombia. A case study was used as a research method. Four in-service English teachers based their inquiry following the reflective approach of professional development. They also took into account the guidelines to design teaching materials proposed by Howard and Major (2004.  Some of the results of their inquiry for the design of the manual involve contextualization, personalization, and students’ needs. A sample of a reading strategy is given in order to illustrate how teachers worked and designed the manual as a product of their inquiry. Conclusions suggest that this professional development practice helped teachers become more aware of their own teaching realities and also helped them to understand their beliefs and practice in teaching reading as a foreign language.

  20. Comparison of Inoculation with the InoqulA and WASP Automated Systems with Manual Inoculation

    Science.gov (United States)

    Croxatto, Antony; Dijkstra, Klaas; Prod'hom, Guy

    2015-01-01

    The quality of sample inoculation is critical for achieving an optimal yield of discrete colonies in both monomicrobial and polymicrobial samples to perform identification and antibiotic susceptibility testing. Consequently, we compared the performance between the InoqulA (BD Kiestra), the WASP (Copan), and manual inoculation methods. Defined mono- and polymicrobial samples of 4 bacterial species and cloudy urine specimens were inoculated on chromogenic agar by the InoqulA, the WASP, and manual methods. Images taken with ImagA (BD Kiestra) were analyzed with the VisionLab version 3.43 image analysis software to assess the quality of growth and to prevent subjective interpretation of the data. A 3- to 10-fold higher yield of discrete colonies was observed following automated inoculation with both the InoqulA and WASP systems than that with manual inoculation. The difference in performance between automated and manual inoculation was mainly observed at concentrations of >106 bacteria/ml. Inoculation with the InoqulA system allowed us to obtain significantly more discrete colonies than the WASP system at concentrations of >107 bacteria/ml. However, the level of difference observed was bacterial species dependent. Discrete colonies of bacteria present in 100- to 1,000-fold lower concentrations than the most concentrated populations in defined polymicrobial samples were not reproducibly recovered, even with the automated systems. The analysis of cloudy urine specimens showed that InoqulA inoculation provided a statistically significantly higher number of discrete colonies than that with WASP and manual inoculation. Consequently, the automated InoqulA inoculation greatly decreased the requirement for bacterial subculture and thus resulted in a significant reduction in the time to results, laboratory workload, and laboratory costs. PMID:25972424

  1. INTRA/Mod3.2. Manual and code description. Volume 2 - User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User`s Manual is an input description. This document, the User`s Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  2. Camp Health Aide Manual = Manual para trabajadores de salud.

    Science.gov (United States)

    Robinson, June Grube; And Others

    This bilingual manual serves as a textbook for migrant Camp Health Aides. Camp Health Aides are members of migrant labor camps enlisted to provide information about health and social services to migrant workers and their families. The manual is divided into 12 tabbed sections representing lessons. Teaching notes printed on contrasting paper…

  3. Improved genetic algorithm in optimization of beam orientation in intensity modulated radiotherapy

    International Nuclear Information System (INIS)

    Ni Xinye; Yang Jianhua; Sun Suping; Yao Yi

    2009-01-01

    Objective: At present beam orientation selection in intensity-modulated radiotherapy (IMRT) is mainly based on empiric knowledge. This study is to evaluate the feasibility of automated beam angle selection. Methods: Genetic algorithm technique which based on beam eye view dose measurement (BEVD-GA) was tested on two clinical cases, including a spine column cancer and a lung cancer. Three plans were obtained under the following different beam configurations: five equiangular-spaced beams, five beams with GA-selected, and five beams with BEVD-GA-selected beams. Then the dose distribution was compared among the three plans. Results: The method, restricting the range of genetic algorithm followed by carrying through genetic operations, not only shortened the optimization time, but also improved the optimization effect. For spine column cancer and lung cancer, the best IMRT plans were obtained with BEVD-GA-selected beams, which used automated beam orientation selection. Conclusions: Comparing with the conventional manual beam orientation selection, beam orientation optimization which is feasible in IMRT planning may significantly improve the efficiency and result. (authors)

  4. HVAC system operation manual of IMEF

    International Nuclear Information System (INIS)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun.

    1997-06-01

    This manual is operation procedures of the IMEF(Irradiated Material Examination Facility) HVAC(Heating, Ventilation and Air Conditioning) System. General operation procedures and test method of the IMEF HVAC system are described. The manual is as follows; 1. HVAC system operation manual 2. HVAC system management guide 3. HVAC system maintenance manual 4. HVAC system air velocity and flowrate measurement manual 5. HVAC system HEPA filter leak test manual 6. HVAC system charcoal filter leak test manual 7. HVAC system HEPA and charcoal filter exchange manual. (author). 8 tabs

  5. Transicion de la Escuela a la Vida Adulta Manual de Informacion para la Provision de Servicios de Transicion a los Jovenes con Impedimentos (Transition from School to Adult Life. Manual of Information for the Provision of Transitional Services for Youth with Disabilities).

    Science.gov (United States)

    Puerto Rico State Dept. of Education, Hato Rey. Office of Special Education.

    This manual has been prepared to orient school personnel in the development of programs for the transition of students with disabilities from school to adult life so that they can fulfill their responsibilities in planning and providing services. The laws under which such services are required are reviewed, and the services and planning are…

  6. A Manual of Style.

    Science.gov (United States)

    Nebraska State Dept. of Education, Lincoln.

    This "Manual of Style" is offered as a guide to assist Nebraska State employees in producing quality written communications and in presenting a consistently professional image of government documents. The manual is not designed to be all-inclusive. Sections of the manual discuss formatting documents, memorandums, letters, mailing…

  7. Autoaspiration versus manual aspiration in transbronchial needle aspiration in diagnosis of intrathoracic lymphadenopathy.

    Science.gov (United States)

    Boonsarngsuk, Viboon; Pongtippan, Atcharaporn; Juthakarn, Sabaitip; Boonsarngsuk, Wison; Kurimoto, Noriaki

    2009-10-01

    Traditionally, aspiration with high negative pressure is recommended to obtain a specimen in transbronchial needle aspiration (TBNA). Undeniably, however, the assistant experiences difficulty in the generation of the negative pressure and precise control of the syringe while performing the procedure. To evaluate the effectiveness of the autoaspiration method created by our plunger lock in comparison with the conventional manual aspiration in the diagnosis of intrathoracic lymphadenopathy by TBNA. A prospective study was conducted on all patients referred for diagnostic TBNA of enlarged intrathoracic lymph nodes. Both automatic and manual aspiration techniques were performed after the needle had been completely inserted into the nodes. The diagnostic yield and the numbers of diagnostic cells or benign lymphoid cells obtained by each technique were compared in the same node. A total of 31 intrathoracic lymph nodes in 24 patients were prospectively studied. Twenty-four nodes (77.4%) were malignancies whereas 7 nodes (22.6%) were benign disease. Adequate lymph node samples were obtained in 30 targets (96.8%), and TBNA revealed definite diagnosis for 25 nodes (80.6%). Both aspiration techniques showed exactly the same diagnostic yield. However, the autoaspiration technique provided significantly more adequate samples than manual aspiration techniques did (P=0.003). The autoaspiration method using our plunger lock was superior to the manual method in obtaining the numbers of adequate samples in TBNA procedures.

  8. MARS CODE MANUAL VOLUME III - Programmer's Manual

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Hwang, Moon Kyu; Jeong, Jae Jun; Kim, Kyung Doo; Bae, Sung Won; Lee, Young Jin; Lee, Won Jae

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This programmer's manual provides a complete list of overall information of code structure and input/output function of MARS. In addition, brief descriptions for each subroutine and major variables used in MARS are also included in this report, so that this report would be very useful for the code maintenance. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  9. Quality Manual

    Science.gov (United States)

    Koch, Michael

    The quality manual is the “heart” of every management system related to quality. Quality assurance in analytical laboratories is most frequently linked with ISO/IEC 17025, which lists the standard requirements for a quality manual. In this chapter examples are used to demonstrate, how these requirements can be met. But, certainly, there are many other ways to do this.

  10. Modelling and analysing oriented fibrous structures

    International Nuclear Information System (INIS)

    Rantala, M; Lassas, M; Siltanen, S; Sampo, J; Takalo, J; Timonen, J

    2014-01-01

    A mathematical model for fibrous structures using a direction dependent scaling law is presented. The orientation of fibrous nets (e.g. paper) is analysed with a method based on the curvelet transform. The curvelet-based orientation analysis has been tested successfully on real data from paper samples: the major directions of fibrefibre orientation can apparently be recovered. Similar results are achieved in tests on data simulated by the new model, allowing a comparison with ground truth

  11. Laboratory training manual on the use of nuclear techniques in animal parasitology

    International Nuclear Information System (INIS)

    1982-01-01

    The Manual is designed for specialist training in the use of nuclear techniques in animal parasitology. The theoretical part contains a general introduction to experimental work in this field. Laboratory exercises are divided into Basic Exercises (17) and Applied Exercises (25) oriented to research in the immunology and pathogenesis of host-parasite interactions using radioisotopic methods and to disease management through the use of radiation-attenuated vaccines. The closing part contains a number of practical guidelines and data for work with radioisotopes in general and for the use of radioisotopic methods in animal parasitology

  12. MOTORIC SPEED AND MANUAL DEXTERITY OF CHILDERN WITH IMPAIRED VISION

    Directory of Open Access Journals (Sweden)

    Dženana Radžo Alibegović

    2017-04-01

    Full Text Available The aim of this study was to estimate the motoric speed and manual dexterity of children with visual impairments. The research is covered by a sample size of 35 participants with visual impairment, with ages between 7 and 15 years, of which 19 participants with visual impairment were male and 16 participants with impaired vision were female. The study was conducted in 17 primary schools in the municipality of Tuzla, Bosnia and Herzegovina. The results showed that the motoric speed and manual dexterity of children with visual impairment is evenly developed on the right and left hand, and also on both hands together and that there is a relationship between the motoric speed and manual dexterity of the right and left hand and both hands together.

  13. ZAG-Otolith: Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control during Variable Radius Centrifugation Following Space Flight

    Science.gov (United States)

    Wood, S. J.; Clarke, A. H.; Rupert, A. H.; Harm, D. L.; Clement, G. R.

    2009-01-01

    Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved with vibrotactile feedback of orientation.

  14. Helicopter Operations and Personnel Safety (Helirescue Manual). Fourth Edition.

    Science.gov (United States)

    Dalle-Molle, John

    The illustrated manual includes information on various aspects of helicopter rescue missions, including mission management roles for key personnel, safety rules around helicopters, requests for helicopter support, sample military air support forms, selection of landing zones, helicopter evacuations, rescuer delivery, passenger unloading, crash…

  15. GO software version 3.0: Volume 1, Overview: Computer Code Manual

    International Nuclear Information System (INIS)

    1988-06-01

    The GO Methodology is a success-oriented probabilistic system performance analysis technique. The methodology can be used to quantify system reliability and availability, identify and rank critical components and the contributors to system failure, construct event trees, perform statistical uncertainty analysis, and evaluate the effects of external events and common cause failures on system performance. This Overview Manual provides a description of the GO methodology, how it can be used, the benefits of using it in the analysis of complex systems, and a comparison of the methodology with fault tree analysis. 14 refs., 35 figs., 9 tabs

  16. SHARP User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Y. Q. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, E. R. [Argonne National Lab. (ANL), Argonne, IL (United States); Thomas, J. W. [Argonne National Lab. (ANL), Argonne, IL (United States); Mahadevan, Vijay S. [Argonne National Lab. (ANL), Argonne, IL (United States); Rahaman, Ronald O. [Argonne National Lab. (ANL), Argonne, IL (United States); Solberg, Jerome [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-31

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  17. SHARP User Manual

    International Nuclear Information System (INIS)

    Yu, Y. Q.; Shemon, E. R.; Thomas, J. W.; Mahadevan, Vijay S.; Rahaman, Ronald O.; Solberg, Jerome

    2016-01-01

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  18. First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach.

    Science.gov (United States)

    Mischnik, Alexander; Mieth, Markus; Busch, Cornelius J; Hofer, Stefan; Zimmermann, Stefan

    2012-08-01

    Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis.

  19. Surface Environmental Surveillance Procedures Manual, PNL-MA-580, Rev. 5

    Energy Technology Data Exchange (ETDEWEB)

    Hanf, Robert W.; Poston, Ted M.; Bisping, Lynn E.

    2007-07-01

    This manual contains the procedures that are used for the collection of routine Surface Environmental Surveillance Project environmental samples and field measurements on and around the Hanford Site. Specific responsibilities for project personnel are also defined.

  20. Research of pneumatic control transmission system for small irradiation samples

    International Nuclear Information System (INIS)

    Bai Zhongxiong; Zhang Haibing; Rong Ru; Zhang Tao

    2008-01-01

    In order to reduce the absorbed dose damage for the operator, pneumatic control has been adopted to realize the rapid transmission of small irradiation samples. On/off of pneumatic circuit and directions for the rapid transmission system are controlled by the electrical control part. The main program initializes the system and detects the location of the manual/automatic change-over switch, and call for the corresponding subprogram to achieve the automatic or manual operation. Automatic subprogram achieves the automatic sample transmission; Manual subprogram completes the deflation, and back and forth movement of the radiation samples. This paper introduces in detail the implementation of the system, in terms of both hardware and software design. (authors)

  1. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  2. Evaluation of manual and automatic manually triggered ventilation performance and ergonomics using a simulation model.

    Science.gov (United States)

    Marjanovic, Nicolas; Le Floch, Soizig; Jaffrelot, Morgan; L'Her, Erwan

    2014-05-01

    In the absence of endotracheal intubation, the manual bag-valve-mask (BVM) is the most frequently used ventilation technique during resuscitation. The efficiency of other devices has been poorly studied. The bench-test study described here was designed to evaluate the effectiveness of an automatic, manually triggered system, and to compare it with manual BVM ventilation. A respiratory system bench model was assembled using a lung simulator connected to a manikin to simulate a patient with unprotected airways. Fifty health-care providers from different professional groups (emergency physicians, residents, advanced paramedics, nurses, and paramedics; n = 10 per group) evaluated manual BVM ventilation, and compared it with an automatic manually triggered device (EasyCPR). Three pathological situations were simulated (restrictive, obstructive, normal). Standard ventilation parameters were recorded; the ergonomics of the system were assessed by the health-care professionals using a standard numerical scale once the recordings were completed. The tidal volume fell within the standard range (400-600 mL) for 25.6% of breaths (0.6-45 breaths) using manual BVM ventilation, and for 28.6% of breaths (0.3-80 breaths) using the automatic manually triggered device (EasyCPR) (P < .0002). Peak inspiratory airway pressure was lower using the automatic manually triggered device (EasyCPR) (10.6 ± 5 vs 15.9 ± 10 cm H2O, P < .001). The ventilation rate fell consistently within the guidelines, in the case of the automatic manually triggered device (EasyCPR) only (10.3 ± 2 vs 17.6 ± 6, P < .001). Significant pulmonary overdistention was observed when using the manual BVM device during the normal and obstructive sequences. The nurses and paramedics considered the ergonomics of the automatic manually triggered device (EasyCPR) to be better than those of the manual device. The use of an automatic manually triggered device may improve ventilation efficiency and decrease the risk of

  3. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    Science.gov (United States)

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  4. Manual on sample-based data collection for fisheries assessment : Examples from Viet Nam

    DEFF Research Database (Denmark)

    Sparre, Per Johan

    with through both detailed discussion and by using simple examples. These examples are mostly based on situations in tropical fisheries and, in particular, experience has been drawn from developing a data collection programme in Viet Nam. The main questions addressed in the manual are which fisheries data...... to collect, where and when to collect them. Only data collected from commercial marine capture fisheries are considered (data from freshwater fisheries, cultured fish and experimental fisheries are excluded). The methodologies used are mainly appropriate for a tropical developing country with many small...

  5. The environmental survey manual: Appendices E, F, G, H, I, J, and K

    International Nuclear Information System (INIS)

    1987-08-01

    Appendices E, F, G, H, I, J and K of the Environmental Survey Manual address the following topics: Field Sampling Protocols and Guidance; Guidelines for Preparation of Quality Assurance Plans; Decontamination Guidance; Data Management and Analysis; Sample and Document Management; Health and Safety Guidance for Sampling and Analysis Teams; Documents for Sampling and Analysis Program

  6. Managing Entrepreneurial Orientation

    NARCIS (Netherlands)

    S. van Doorn (Sebastiaan)

    2012-01-01

    textabstractIn this dissertation, we evaluate the roles senior management teams and individual middle managers play in realizing the performance benefits of entrepreneurial orientations. We investigate the role of senior management teams by focusing on a sample of 9.000 firms in the Netherlands. The

  7. Fuel Element Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Burley, H.H. [ed.

    1956-08-01

    It is the purpose of the Fuel Element Technical Manual to Provide a single document describing the fabrication processes used in the manufacture of the fuel element as well as the technical bases for these processes. The manual will be instrumental in the indoctrination of personnel new to the field and will provide a single data reference for all personnel involved in the design or manufacture of the fuel element. The material contained in this manual was assembled by members of the Engineering Department and the Manufacturing Department at the Hanford Atomic Products Operation between the dates October, 1955 and June, 1956. Arrangement of the manual. The manual is divided into six parts: Part I--introduction; Part II--technical bases; Part III--process; Part IV--plant and equipment; Part V--process control and improvement; and VI--safety.

  8. DAKOTA : a multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Eldred, Michael Scott; Vigil, Dena M.; Dalbey, Keith R.; Bohnhoff, William J.; Adams, Brian M.; Swiler, Laura Painton; Lefantzi, Sophia (Sandia National Laboratories, Livermore, CA); Hough, Patricia Diane (Sandia National Laboratories, Livermore, CA); Eddy, John P.

    2011-12-01

    The DAKOTA (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a flexible and extensible interface between simulation codes and iterative analysis methods. DAKOTA contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quantification with sampling, reliability, and stochastic expansion methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the DAKOTA toolkit provides a flexible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a theoretical manual for selected algorithms implemented within the DAKOTA software. It is not intended as a comprehensive theoretical treatment, since a number of existing texts cover general optimization theory, statistical analysis, and other introductory topics. Rather, this manual is intended to summarize a set of DAKOTA-related research publications in the areas of surrogate-based optimization, uncertainty quantification, and optimization under uncertainty that provide the foundation for many of DAKOTA's iterative analysis capabilities.

  9. Instruction manual for ORNL tandem high abundance sensitivity mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; McKown, H.S.; Chrisite, W.H.; Walker, R.L.; Carter, J.A.

    1976-06-01

    This manual describes the physical characteristics of the tandem mass spectrometer built by Oak Ridge National Laboratory for the International Atomic Energy Agency. Specific requirements met include ability to run small samples, high abundance sensitivity, good precision and accuracy, and adequate sample throughput. The instrument is capable of running uranium samples as small as 10 -12 g and has an abundance sensitivity in excess of 10 6 . Precision and accuracy are enhanced by a special sweep control circuit. Sample throughput is 6 to 12 samples per day. Operating instructions are also given

  10. Family orientation for the development and formation table maners in 4 to 5 years old children

    Directory of Open Access Journals (Sweden)

    Lidielys González Tamayo

    2014-03-01

    Full Text Available The Cuban family should obtain an elevated preparation for the formation of table manners or habits in children. The formative activities to take place should have to contribute priorities for all. Departing from the study which had taken place in reference to the preparation of the families about the formation of table manners or habits and a bibliographical study related with the problem. As a result of work, a manual is offered to orient and direct the family on how to develop table habits in 4-5 years old children and orientations for its effective use in any center.

  11. Procurement of Library Materials in the Federal Government; An Orientation Aid Prepared for the Federal Library Committee.

    Science.gov (United States)

    Falk, Leslie K.

    This handbook is designed primarily as a general orientation aid, not an operation manual. It presents the background (mainly regulatory) of Federal procurement work, details, devices and tactics found to be successful, and calls attention to special sources of supply. Although planned as an aid for librarians who are engaged in Federal…

  12. RaPToRS Sample Delivery System

    Science.gov (United States)

    Henchen, Robert; Shibata, Kye; Krieger, Michael; Pogozelski, Edward; Padalino, Stephen; Glebov, Vladimir; Sangster, Craig

    2010-11-01

    At various labs (NIF, LLE, NRL), activated material samples are used to measure reaction properties. The Rapid Pneumatic Transport of Radioactive Samples (RaPToRS) system quickly and safely moves these radioactive samples through a closed PVC tube via airflow. The carrier travels from the reaction chamber to the control and analysis station, pneumatically braking at the outlet. A reversible multiplexer routes samples from various locations near the shot chamber to the analysis station. Also, the multiplexer allows users to remotely load unactivated samples without manually approaching the reaction chamber. All elements of the system (pneumatic drivers, flow control valves, optical position sensors, multiplexers, Geiger counters, and release gates at the analysis station) can be controlled manually or automatically using a custom LabVIEW interface. A prototype is currently operating at NRL in Washington DC. Prospective facilities for Raptors systems include LLE and NIF.

  13. Radiological control manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPP and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP.

  14. Radiological control manual. Revision 1

    International Nuclear Information System (INIS)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPP and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP

  15. CRISP instrument manual

    International Nuclear Information System (INIS)

    Bucknall, D.G.; Langridge, Sean

    1997-05-01

    This document is a user manual for CRISP, one of the two neutron reflectomers at ISIS. CRISP is highly automated allowing precision reproducible measurements. The manual provides detailed instructions for the setting-up and running of the instrument and advice on data analysis. (UK)

  16. Investigation of the Anisotropic Thermoelectric Properties of Oriented Polycrystalline SnSe

    Directory of Open Access Journals (Sweden)

    Yulong Li

    2015-06-01

    Full Text Available Polycrystalline SnSe was synthesized by a melting-annealing-sintering process. X-ray diffraction reveals the sample possesses pure phase and strong orientation along [h00] direction. The degree of the orientations was estimated and the anisotropic thermoelectric properties are characterized. The polycrystalline sample shows a low electrical conductivity and a positive and large Seebeck coefficient. The low thermal conductivity is also observed in polycrystalline sample, but slightly higher than that of single crystal. The minimum value of thermal conductivity was measured as 0.3 W/m·K at 790 K. With the increase of the orientation factor, both electrical and thermal conductivities decrease, but the thermopowers are unchanged. As a consequence, the zT values remain unchanged in the polycrystalline samples despite the large variation in the degree of orientation.

  17. Interfacial orientation and misorientation relationships in nanolamellar Cu/Nb composites using transmission-electron-microscope-based orientation and phase mapping

    International Nuclear Information System (INIS)

    Liu, X.; Nuhfer, N.T.; Rollett, A.D.; Sinha, S.; Lee, S.-B.; Carpenter, J.S.; LeDonne, J.E.; Darbal, A.; Barmak, K.

    2014-01-01

    A transmission-electron-microscope-based orientation mapping technique that makes use of beam precession to achieve near-kinematical conditions was used to map the phase and crystal orientations in nanolamellar Cu/Nb composites with average layer thicknesses of 86, 30 and 18 nm. Maps of high quality and reliability were obtained by comparing the recorded diffraction patterns with pre-calculated templates. Particular care was taken in optimizing the dewarping parameters and in calibrating the frames of reference. Layers with thicknesses as low as 4 nm were successfully mapped. Heterophase interface plane and character distributions (HIPD and HICD, respectively) of Cu and Nb phases from the samples were determined from the orientation maps. In addition, local orientation relation stereograms of the Cu/Nb interfaces were calculated, and these revealed the detailed layer-to-layer texture information. The results are in agreement with previously reported neutron-diffraction-based and precession-electron-diffraction-based measurements on an accumulated roll bonding (ARB)-fabricated Cu/Nb sample with an average layer thickness of 30 nm as well as scanning-electron-microscope-based electron backscattered diffraction HIPD/HICD plots of ARB-fabricated Cu/Nb samples with layer thicknesses between 200 and 600 nm

  18. Salinas : theory manual.

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Timothy Francis; Reese, Garth M.; Bhardwaj, Manoj Kumar

    2004-08-01

    This manual describes the theory behind many of the constructs in Salinas. For a more detailed description of how to use Salinas , we refer the reader to Salinas, User's Notes. Many of the constructs in Salinas are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Salinas are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programer-notes manual, the user's notes and of course the material in the open literature.

  19. PCs The Missing Manual

    CERN Document Server

    Karp, David

    2005-01-01

    Your vacuum comes with one. Even your blender comes with one. But your PC--something that costs a whole lot more and is likely to be used daily and for tasks of far greater importance and complexity--doesn't come with a printed manual. Thankfully, that's not a problem any longer: PCs: The Missing Manual explains everything you need to know about PCs, both inside and out, and how to keep them running smoothly and working the way you want them to work. A complete PC manual for both beginners and power users, PCs: The Missing Manual has something for everyone. PC novices will appreciate the una

  20. Operations and Maintenance Manual, Atmospheric Contaminant Sensor, Revision B.

    Science.gov (United States)

    National Aeronautics and Space Administration, Washington, DC.

    The sensor is a mass spectrometer system which continuously monitors the atmospheric constituents of hydrogen, water vapor, nitrogen, oxygen, and carbon dioxide, and monitors the Freons on a demand sampling basis. The manual provides a system description, operational procedures, and maintenance and troubleshooting instructions. Circuit diagrams…

  1. SPARK Version 1.1 user manual

    International Nuclear Information System (INIS)

    Weissenburger, D.W.

    1988-01-01

    This manual describes the input required to use Version 1.1 of the SPARK computer code. SPARK 1.1 is a library of FORTRAN main programs and subprograms designed to calculate eddy currents on conducting surfaces where current flow is assumed zero in the direction normal to the surface. Surfaces are modeled with triangular and/or quadrilateral elements. Lorentz forces produced by the interaction of eddy currents with background magnetic fields can be output at element nodes in a form compatible with most structural analysis codes. In addition, magnetic fields due to eddy currents can be determined at points off the surface. Version 1.1 features eddy current streamline plotting with optional hidden-surface-removal graphics and topological enhancements that allow essentially any orientable surface to be modeled. SPARK also has extensive symmetry specification options. In order to make the manual as self-contained as possible, six appendices are included that present summaries of the symmetry options, topological options, coil options and code algorithms, with input and output examples. An edition of SPARK 1.1 is available on the Cray computers at the National Magnetic Fusion Energy Computer Center at Livermore, California. Another more generic edition is operational on the VAX computers at the Princeton Plasma Physics Laboratory and is available on magnetic tape by request. The generic edition requires either the GKS or PLOT10 graphics package and the IMSL or NAG mathematical package. Requests from outside the United States will be subject to applicable federal regulations regarding dissemination of computer programs. 22 refs

  2. SPARK Version 1. 1 user manual

    Energy Technology Data Exchange (ETDEWEB)

    Weissenburger, D.W.

    1988-01-01

    This manual describes the input required to use Version 1.1 of the SPARK computer code. SPARK 1.1 is a library of FORTRAN main programs and subprograms designed to calculate eddy currents on conducting surfaces where current flow is assumed zero in the direction normal to the surface. Surfaces are modeled with triangular and/or quadrilateral elements. Lorentz forces produced by the interaction of eddy currents with background magnetic fields can be output at element nodes in a form compatible with most structural analysis codes. In addition, magnetic fields due to eddy currents can be determined at points off the surface. Version 1.1 features eddy current streamline plotting with optional hidden-surface-removal graphics and topological enhancements that allow essentially any orientable surface to be modeled. SPARK also has extensive symmetry specification options. In order to make the manual as self-contained as possible, six appendices are included that present summaries of the symmetry options, topological options, coil options and code algorithms, with input and output examples. An edition of SPARK 1.1 is available on the Cray computers at the National Magnetic Fusion Energy Computer Center at Livermore, California. Another more generic edition is operational on the VAX computers at the Princeton Plasma Physics Laboratory and is available on magnetic tape by request. The generic edition requires either the GKS or PLOT10 graphics package and the IMSL or NAG mathematical package. Requests from outside the United States will be subject to applicable federal regulations regarding dissemination of computer programs. 22 refs.

  3. Trabecular architecture of the manual elements reflects locomotor patterns in primates.

    Science.gov (United States)

    Matarazzo, Stacey A

    2015-01-01

    The morphology of trabecular bone has proven sensitive to loading patterns in the long bones and metacarpal heads of primates. It is expected that we should also see differences in the manual digits of primates that practice different methods of locomotion. Primate proximal and middle phalanges are load-bearing elements that are held in different postures and experience different mechanical strains during suspension, quadrupedalism, and knuckle walking. Micro CT scans of the middle phalanx, proximal phalanx and the metacarpal head of the third ray were used to examine the pattern of trabecular orientation in Pan, Gorilla, Pongo, Hylobates and Macaca. Several zones, i.e., the proximal ends of both phalanges and the metacarpal heads, were capable of distinguishing between knuckle-walking, quadrupedal, and suspensory primates. Orientation and shape seem to be the primary distinguishing factors but differences in bone volume, isotropy index, and degree of anisotropy were seen across included taxa. Suspensory primates show primarily proximodistal alignment in all zones, and quadrupeds more palmar-dorsal orientation in several zones. Knuckle walkers are characterized by having proximodistal alignment in the proximal ends of the phalanges and a palmar-dorsal alignment in the distal ends and metacarpal heads. These structural differences may be used to infer locmotor propensities of extinct primate taxa.

  4. Transportable Xenon Laboratory (TXL-1) Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Robert C.; Stewart, Timothy L.; Willett, Jesse A.; Woods, Vincent T.

    2011-03-07

    The Transportable Xenon Laboratory Operations Manual is a guide to set up and shut down TXL, a fully contained laboratory made up of instruments to identify and measure concentrations of the radioactive isotopes of xenon by taking air samples and analyzing them. The TXL is housed in a standard-sized shipping container. TXL can be shipped to and function in any country in the world.

  5. Making The Most of Medical orientation; A New Approach.

    Directory of Open Access Journals (Sweden)

    Dr Jonathan Taitz

    2004-02-01

    Full Text Available Orientating new junior medical staff can be a complex and time consuming task. Traditional models have typically involved a day or longer of lectures. This involves a large number of senior staff being available on the first day of term. It also means that junior staff not present on the first day had any access to an orientation program at all. Evaluation of our program confirmed the belief that the day was dull and that there was simply too much information for new staff to absorb. As a result of this feedback we extensively updated our orientation program. Pre-reading of the junior staff manual became compulsory. We departed from the traditional lecture style program and devised a new ten- station scenario based interactive program. The stations were designed to cover aspects of the hospital’s mandatory education and key educational requirements in order to function effectively on our campus. Station leaders were selected and trained in the goals of the new process. Several of our secondment sites were engaged in the development of the project topics. We hoped that our secondment sites would be relieved of some orientation responsibility if core material was delivered centrally. The strength of the new orientation is that it is portable, reproducible and uniform. It is also available via video conferencing. A single person can educate new staff in three hours if the need arises. Most importantly all new staff will have access to the program within a week of starting a term at our hospital.

  6. Alternating sample changer and an automatic sample changer for liquid scintillation counting of alpha-emitting materials

    International Nuclear Information System (INIS)

    Thorngate, J.H.

    1977-08-01

    Two sample changers are described that were designed for liquid scintillation counting of alpha-emitting samples prepared using solvent-extraction chemistry. One operates manually but changes samples without exposing the photomultiplier tube to light, allowing the high voltage to remain on for improved stability. The other is capable of automatically counting up to 39 samples. An electronic control for the automatic sample changer is also described

  7. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies.

    Science.gov (United States)

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung Hoi

    2017-03-01

    ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol. The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions (serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods. ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤1+ reaction grade do.

  8. A morphological basis for orientation tuning in primary visual cortex.

    Science.gov (United States)

    Mooser, François; Bosking, William H; Fitzpatrick, David

    2004-08-01

    Feedforward connections are thought to be important in the generation of orientation-selective responses in visual cortex by establishing a bias in the sampling of information from regions of visual space that lie along a neuron's axis of preferred orientation. It remains unclear, however, which structural elements-dendrites or axons-are ultimately responsible for conveying this sampling bias. To explore this question, we have examined the spatial arrangement of feedforward axonal connections that link non-oriented neurons in layer 4 and orientation-selective neurons in layer 2/3 of visual cortex in the tree shrew. Target sites of labeled boutons in layer 2/3 resulting from focal injections of biocytin in layer 4 show an orientation-specific axial bias that is sufficient to confer orientation tuning to layer 2/3 neurons. We conclude that the anisotropic arrangement of axon terminals is the principal source of the orientation bias contributed by feedforward connections.

  9. A simple hand-held magnet array for efficient and reproducible SABRE hyperpolarisation using manual sample shaking.

    Science.gov (United States)

    Richardson, Peter M; Jackson, Scott; Parrott, Andrew J; Nordon, Alison; Duckett, Simon B; Halse, Meghan E

    2018-07-01

    Signal amplification by reversible exchange (SABRE) is a hyperpolarisation technique that catalytically transfers nuclear polarisation from parahydrogen, the singlet nuclear isomer of H 2 , to a substrate in solution. The SABRE exchange reaction is carried out in a polarisation transfer field (PTF) of tens of gauss before transfer to a stronger magnetic field for nuclear magnetic resonance (NMR) detection. In the simplest implementation, polarisation transfer is achieved by shaking the sample in the stray field of a superconducting NMR magnet. Although convenient, this method suffers from limited reproducibility and cannot be used with NMR spectrometers that do not have appreciable stray fields, such as benchtop instruments. Here, we use a simple hand-held permanent magnet array to provide the necessary PTF during sample shaking. We find that the use of this array provides a 25% increase in SABRE enhancement over the stray field approach, while also providing improved reproducibility. Arrays with a range of PTFs were tested, and the PTF-dependent SABRE enhancements were found to be in excellent agreement with comparable experiments carried out using an automated flow system where an electromagnet is used to generate the PTF. We anticipate that this approach will improve the efficiency and reproducibility of SABRE experiments carried out using manual shaking and will be particularly useful for benchtop NMR, where a suitable stray field is not readily accessible. The ability to construct arrays with a range of PTFs will also enable the rapid optimisation of SABRE enhancement as function of PTF for new substrate and catalyst systems. © 2017 The Authors Magnetic Resonance in Chemistry Published by John Wiley & Sons Ltd.

  10. Eco-Innovation Manual

    DEFF Research Database (Denmark)

    O'Hare, Jamie Alexander; McAloone, Tim C.; Pigosso, Daniela Cristina Antelmi

    Aim of this manual is to introduce a methodology for the implementation of eco‐innovation within small and medium sized companies in developing and emerging economies. The intended audience of this manual is organizations that provide professional services to guide and support manufacturing compa...... companies to improve their sustainability performance....

  11. Identification of cultivated land using remote sensing images based on object-oriented artificial bee colony algorithm

    Science.gov (United States)

    Li, Nan; Zhu, Xiufang

    2017-04-01

    Cultivated land resources is the key to ensure food security. Timely and accurate access to cultivated land information is conducive to a scientific planning of food production and management policies. The GaoFen 1 (GF-1) images have high spatial resolution and abundant texture information and thus can be used to identify fragmentized cultivated land. In this paper, an object-oriented artificial bee colony algorithm was proposed for extracting cultivated land from GF-1 images. Firstly, the GF-1 image was segmented by eCognition software and some samples from the segments were manually identified into 2 types (cultivated land and non-cultivated land). Secondly, the artificial bee colony (ABC) algorithm was used to search for classification rules based on the spectral and texture information extracted from the image objects. Finally, the extracted classification rules were used to identify the cultivated land area on the image. The experiment was carried out in Hongze area, Jiangsu Province using wide field-of-view sensor on the GF-1 satellite image. The total precision of classification result was 94.95%, and the precision of cultivated land was 92.85%. The results show that the object-oriented ABC algorithm can overcome the defect of insufficient spectral information in GF-1 images and obtain high precision in cultivated identification.

  12. AST: an automated sequence-sampling method for improving the taxonomic diversity of gene phylogenetic trees.

    Science.gov (United States)

    Zhou, Chan; Mao, Fenglou; Yin, Yanbin; Huang, Jinling; Gogarten, Johann Peter; Xu, Ying

    2014-01-01

    A challenge in phylogenetic inference of gene trees is how to properly sample a large pool of homologous sequences to derive a good representative subset of sequences. Such a need arises in various applications, e.g. when (1) accuracy-oriented phylogenetic reconstruction methods may not be able to deal with a large pool of sequences due to their high demand in computing resources; (2) applications analyzing a collection of gene trees may prefer to use trees with fewer operational taxonomic units (OTUs), for instance for the detection of horizontal gene transfer events by identifying phylogenetic conflicts; and (3) the pool of available sequences is biased towards extensively studied species. In the past, the creation of subsamples often relied on manual selection. Here we present an Automated sequence-Sampling method for improving the Taxonomic diversity of gene phylogenetic trees, AST, to obtain representative sequences that maximize the taxonomic diversity of the sampled sequences. To demonstrate the effectiveness of AST, we have tested it to solve four problems, namely, inference of the evolutionary histories of the small ribosomal subunit protein S5 of E. coli, 16 S ribosomal RNAs and glycosyl-transferase gene family 8, and a study of ancient horizontal gene transfers from bacteria to plants. Our results show that the resolution of our computational results is almost as good as that of manual inference by domain experts, hence making the tool generally useful to phylogenetic studies by non-phylogeny specialists. The program is available at http://csbl.bmb.uga.edu/~zhouchan/AST.php.

  13. Perceived Stigma, Discrimination, and Disclosure of Sexual Orientation Among a Sample of Lesbian Veterans Receiving Care in the Department of Veterans Affairs.

    Science.gov (United States)

    Mattocks, Kristin M; Sullivan, J Cherry; Bertrand, Christina; Kinney, Rebecca L; Sherman, Michelle D; Gustason, Carolyn

    2015-06-01

    Many lesbian women experience stigma and discrimination from their healthcare providers as a result of their sexual orientation. Additionally, others avoid disclosure of their sexual orientation to their providers for fear of mistreatment. With the increasing number of lesbian, gay, bisexual, and transgender (LGBT) veterans seeking care from the Veterans Health Administration (VHA), it is important to understand lesbian veterans' experiences with stigma, discrimination, and disclosure of sexual orientation. This article examines lesbian veterans' experiences with perceived stigma and discrimination in VHA healthcare, their perspectives on disclosure of sexual orientation to VHA providers, and their recommendations for improvements in VHA healthcare to create a welcoming environment for lesbian veterans. This is a mixed methods study of twenty lesbian veterans at four VHA facilities. The women veterans participated in a one-hour interview and then completed an anonymous survey. Ten percent of lesbian veterans had experienced mistreatment from VHA staff or providers, but nearly 50% feared that their Veterans Affairs (VA) providers would mistreat them if they knew about their sexual orientation. A majority of lesbian veterans (70%) believed that VHA providers should never ask about sexual orientation or should only ask if the veteran wanted to discuss it. A majority (80%) believed the VHA had taken steps to create a welcoming environment for LBGT veterans. Though many lesbian veterans have fears of stigma and discrimination in the context of VHA care, few have experienced this. Most lesbian veterans believed the VHA was trying to create a welcoming environment for its LGBT veterans. Future research should focus on expanding this study to include a larger and more diverse sample of lesbian, gay, bisexual, and transgender veterans receiving care at VA facilities across the country.

  14. User Manuals for a Primary Care Electronic Medical Record System: A Mixed Methods Study of User- and Vendor-Generated Documents.

    Science.gov (United States)

    Shachak, Aviv; Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R; Lemieux-Charles, Louise

    2013-06-04

    Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and adapted to specific organizational contexts and workflows. The main limitation of the study

  15. User Manuals for a Primary Care Electronic Medical Record System: A Mixed Methods Study of User- and Vendor-Generated Documents

    Science.gov (United States)

    Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R.; Lemieux-Charles, Louise

    2015-01-01

    Research problem Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. Research question What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Literature review Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. Methodology We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. Results and discussion The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and

  16. FINAS. Example manual. 2

    International Nuclear Information System (INIS)

    Iwata, Koji; Tsukimori, Kazuyuki; Ueno, Mutsuo

    2003-12-01

    FINAS is a general purpose structural analysis computer program which was developed by Japan Nuclear Cycle Development Institute for the analysis of static, dynamic and thermal responses of elastic and inelastic structures by the finite element method. This manual contains typical analysis examples that illustrate applications of FINAS to a variety of structural engineering problems. The first part of this manual presents fundamental examples in which numerical solutions by FINAS are compared with some analytical reference solutions, and the second part of this manual presents more complex examples intended for practical application. All the input data images and principal results for each problem are included in this manual for beginners' convenience. All the analyses are performed by using the FINAS Version 13.0. (author)

  17. Biosafety Manual

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce W.

    2010-05-18

    Work with or potential exposure to biological materials in the course of performing research or other work activities at Lawrence Berkeley National Laboratory (LBNL) must be conducted in a safe, ethical, environmentally sound, and compliant manner. Work must be conducted in accordance with established biosafety standards, the principles and functions of Integrated Safety Management (ISM), this Biosafety Manual, Chapter 26 (Biosafety) of the Health and Safety Manual (PUB-3000), and applicable standards and LBNL policies. The purpose of the Biosafety Program is to protect workers, the public, agriculture, and the environment from exposure to biological agents or materials that may cause disease or other detrimental effects in humans, animals, or plants. This manual provides workers; line management; Environment, Health, and Safety (EH&S) Division staff; Institutional Biosafety Committee (IBC) members; and others with a comprehensive overview of biosafety principles, requirements from biosafety standards, and measures needed to control biological risks in work activities and facilities at LBNL.

  18. Accurate Molecular Orientation Analysis Using Infrared p-Polarized Multiple-Angle Incidence Resolution Spectrometry (pMAIRS) Considering the Refractive Index of the Thin Film Sample.

    Science.gov (United States)

    Shioya, Nobutaka; Shimoaka, Takafumi; Murdey, Richard; Hasegawa, Takeshi

    2017-06-01

    Infrared (IR) p-polarized multiple-angle incidence resolution spectrometry (pMAIRS) is a powerful tool for analyzing the molecular orientation in an organic thin film. In particular, pMAIRS works powerfully for a thin film with a highly rough surface irrespective of degree of the crystallinity. Recently, the optimal experimental condition has comprehensively been revealed, with which the accuracy of the analytical results has largely been improved. Regardless, some unresolved matters still remain. A structurally isotropic sample, for example, yields different peak intensities in the in-plane and out-of-plane spectra. In the present study, this effect is shown to be due to the refractive index of the sample film and a correction factor has been developed using rigorous theoretical methods. As a result, with the use of the correction factor, organic materials having atypical refractive indices such as perfluoroalkyl compounds ( n = 1.35) and fullerene ( n = 1.83) can be analyzed with high accuracy comparable to a compound having a normal refractive index of approximately 1.55. With this improved technique, we are also ready for discriminating an isotropic structure from an oriented sample having the magic angle of 54.7°.

  19. AUTOMATIC ORIENTATION OF LARGE BLOCKS OF OBLIQUE IMAGES

    Directory of Open Access Journals (Sweden)

    E. Rupnik

    2013-05-01

    Full Text Available Nowadays, multi-camera platforms combining nadir and oblique cameras are experiencing a revival. Due to their advantages such as ease of interpretation, completeness through mitigation of occluding areas, as well as system accessibility, they have found their place in numerous civil applications. However, automatic post-processing of such imagery still remains a topic of research. Configuration of cameras poses a challenge on the traditional photogrammetric pipeline used in commercial software and manual measurements are inevitable. For large image blocks it is certainly an impediment. Within theoretical part of the work we review three common least square adjustment methods and recap on possible ways for a multi-camera system orientation. In the practical part we present an approach that successfully oriented a block of 550 images acquired with an imaging system composed of 5 cameras (Canon Eos 1D Mark III with different focal lengths. Oblique cameras are rotated in the four looking directions (forward, backward, left and right by 45° with respect to the nadir camera. The workflow relies only upon open-source software: a developed tool to analyse image connectivity and Apero to orient the image block. The benefits of the connectivity tool are twofold: in terms of computational time and success of Bundle Block Adjustment. It exploits the georeferenced information provided by the Applanix system in constraining feature point extraction to relevant images only, and guides the concatenation of images during the relative orientation. Ultimately an absolute transformation is performed resulting in mean re-projection residuals equal to 0.6 pix.

  20. ACT Plan: Technical Manual. 2013/2014

    Science.gov (United States)

    ACT, Inc., 2013

    2013-01-01

    This manual contains information about the American College Test (ACT) Plan® program. The principal focus of this manual is to document the Plan program's technical adequacy in light of its intended purposes. This manual supersedes the 2011 edition. The content of this manual responds to requirements of the testing industry as established in the…

  1. Investigation the Relationship between Goal Orientation and Parenting Styles among Sample of Jordanian University Students

    Science.gov (United States)

    Mahasneh, Ahmad M.

    2014-01-01

    The primary purpose of this study is to examine the relationship between goal orientation and parenting styles. Participants of the study completed 650 goal orientation and parenting styles questionnaires. Means, standard deviations, regression and correlation analysis were used for data in establishing the dependence of the two variables. Results…

  2. Effect of layer thickness and printing orientation on mechanical properties and dimensional accuracy of 3D printed porous samples for bone tissue engineering.

    Directory of Open Access Journals (Sweden)

    Arghavan Farzadi

    Full Text Available Powder-based inkjet 3D printing method is one of the most attractive solid free form techniques. It involves a sequential layering process through which 3D porous scaffolds can be directly produced from computer-generated models. 3D printed products' quality are controlled by the optimal build parameters. In this study, Calcium Sulfate based powders were used for porous scaffolds fabrication. The printed scaffolds of 0.8 mm pore size, with different layer thickness and printing orientation, were subjected to the depowdering step. The effects of four layer thicknesses and printing orientations, (parallel to X, Y and Z, on the physical and mechanical properties of printed scaffolds were investigated. It was observed that the compressive strength, toughness and Young's modulus of samples with 0.1125 and 0.125 mm layer thickness were more than others. Furthermore, the results of SEM and μCT analyses showed that samples with 0.1125 mm layer thickness printed in X direction have more dimensional accuracy and significantly close to CAD software based designs with predefined pore size, porosity and pore interconnectivity.

  3. Nutritional Screening of Children: A Manual for Screening & Followup.

    Science.gov (United States)

    Bureau of Community Health Services (DHHS/PHS), Rockville, MD.

    This manual shows health providers how to perform precisely and expertly each step of several procedures used in screening children for nutritional problems. It is intended for all health providers who are involved in weighing and measuring children, recording and plotting measurements on growth charts, taking blood samples to test for iron…

  4. Axis of eye rotation changes with head-pitch orientation during head impulses about earth-vertical.

    Science.gov (United States)

    Migliaccio, Americo A; Schubert, Michael C; Clendaniel, Richard A; Carey, John P; Della Santina, Charles C; Minor, Lloyd B; Zee, David S

    2006-06-01

    The goal of this study was to assess how the axis of head rotation, Listing's law, and eye position influence the axis of eye rotation during brief, rapid head rotations. We specifically asked how the axis of eye rotation during the initial angular vestibuloocular reflex (VOR) changed when the pitch orientation of the head relative to Earth-vertical was varied, but the initial position of the eye in the orbit and the orientation of Listing's plane with respect to the head were fixed. We measured three-dimensional eye and head rotation axes in eight normal humans using the search coil technique during head-and-trunk (whole-body) and head-on-trunk (head-only) "impulses" about an Earth-vertical axis. The head was initially oriented at one of five pitch angles (30 degrees nose down, 15 degrees nose down, 0 degrees, 15 degrees nose up, 30 degrees nose up). The fixation target was always aligned with the nasooccipital axis. Whole-body impulses were passive, unpredictable, manual, rotations with peak-amplitude of approximately 20 degrees , peak-velocity of approximately 80 degrees /s, and peak-acceleration of approximately 1000 degrees /s2. Head-only impulses were also passive, unpredictable, manual, rotations with peak-amplitude of approximately 20 degrees , peak-velocity of approximately 150 degrees /s, and peak-acceleration of approximately 3000 degrees /s2. During whole-body impulses, the axis of eye rotation tilted in the same direction, and by an amount proportional (0.51 +/- 0.09), to the starting pitch head orientation (P rotation could be predicted from vectorial summation of the gains (eye velocity/head velocity) obtained for rotations about the pure yaw and roll head axes. Thus, even when the orientation of Listing's plane and eye position in the orbit are fixed, the axis of eye rotation during the VOR reflects a compromise between the requirements of Listing's law and a perfectly compensatory VOR.

  5. Load research manual. Volume 2. Fundamentals of implementing load research procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brandenburg, L.; Clarkson, G.; Grund, Jr., C.; Leo, J.; Asbury, J.; Brandon-Brown, F.; Derderian, H.; Mueller, R.; Swaroop, R.

    1980-11-01

    This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. In Volumes 1 and 2, procedures are suggested for determining data requirements for load research, establishing the size and customer composition of a load survey sample, selecting and using equipment to record customer electricity usage, processing data tapes from the recording equipment, and analyzing the data. Statistical techniques used in customer sampling are discussed in detail. The costs of load research also are estimated, and ongoing load research programs at three utilities are described. The manual includes guides to load research literature and glossaries of load research and statistical terms.

  6. Oriented Structure of Pentablock Copolymers Induced by Solution Extrusion

    Science.gov (United States)

    Harada, Tamotsu; Bates, Frank S.; Lodge, Timothy P.

    2002-03-01

    Highly oriented structure of a poly(styrene-co-butadiene) pentablock copolymer (Mw; 104,700 g/mol, weight percentage of polybutadiene blocks; 29 wt of concentrated solutions. The pentablock copolymer was dissolved into mixtures of toluene and heptane, and the polymer concentration ranged from 40 wt extrusion, the pentablock copolymer was solidified either by coagulation in methanol or by evaporation of the solvent. Interestingly, a highly oriented lamellar structure was confirmed through the small angle X-ray scattering over a specific range of heptane composition, which is a good solvent for polybutadiene, although the hexagonal cylinder morphology was identified for the melt sample. The transition from the oriented lamellar to highly oriented cylinder structure was observed by annealing the samples at temperatures above the glass transition temperature of polystyrene. Moreover, a transition from parallel to perpendicular orientation in the lamellar state was observed with an increase of the extrusion shear rate. A comparison between pentablock and triblock copolymers will be also discussed.

  7. Orientation Characterisation of Aerospace Materials by Spatially Resolved Acoustic Spectroscopy

    International Nuclear Information System (INIS)

    Li, Wenqi; Coulson, Jethro; Smith, Richard J; Clark, Matt; Somekh, Michael G; Sharples, Steve D; Aveson, John W

    2014-01-01

    Material characteristics in metals such as strength, stiffness and fracture resistance are strongly related to the underlying microstructure. The crystallographic structure and orientation are related to the ultrasonic properties through the stiffness matrix. In individual grains it is possible to analytically determine the ultrasonic velocity from the orientation and stiffness, or determine the stiffness from the known orientation and measured velocity. In this paper we present a technique for imaging the crystallographic orientation of grains in metals using spatially resolved acoustic spectroscopy (SRAS) and a novel inverse solver that can determine the crystallographic orientation from the known stiffness matrix for the material and the SRAS velocity measurement. Previously we have shown the ability of this technique to determine the orientation on single crystal nickel samples; we extended the technique to multigrain industrial metals, such as aluminium, nickel and Inconel. The comparison between SRAS and electron backscatter diffraction (EBSD) on the nickel sample is presented. SRAS is a fast, accurate, quantitative and robust technique for imaging material microstructure and orientation over a wide range of scales and industrial materials

  8. Facet orientation and tropism: associations with spondylolysis.

    Science.gov (United States)

    Kalichman, Leonid; Guermazi, Ali; Li, Ling; Hunter, David J; Suri, Pradeep

    2010-04-01

    Cross-sectional study. To evaluate the association between lumbar spine facet joint orientation, facet joint tropism, and spondylolysis identified by multidetector computed tomography (CT) in the community-based Framingham Heart Study. The association between lumbar spondylolysis and facet orientation and tropism remains unclear. This study was an ancillary project to the Framingham Heart Study. Three thousand five hundred twenty-nine participants of the Framingham Heart Study aged 40 to 80 years underwent multidetector CT imaging to assess aortic calcification. One hundred ninety-one subjects were included in this ancillary study. Facet joint features and spondylolysis were evaluated on CT scans. The final analyzed sample included 104 men with mean age 51.90+/-11.25 years and 84 women with mean age 53.61+/-10.20 years. The association between spondylolysis and facet orientation and tropism was examined using univariate and multivariate analyses. Spondylolysis was prevalent in 11.5% of the total population. chi2 test demonstrated a significant sex difference in prevalence of spondylolysis (P=0.0154), with almost 3 times higher prevalence among men. There was no statistically significant difference in facet orientation and continuous facet tropism between individuals with and without spondylolysis at the L5 level (P=0.49 to 0.91). After adjustment for age, sex, and body mass index, no significant association between the occurrence of spondylolysis and facet orientation and tropism was found. In the studied sample the prevalence of facet joint osteoarthritis was significantly higher in individuals with spondylolysis than in those without spondylolysis at both sides of L4-L5 spinal level (P=0.044 at the right side and P=0.003 at the left side) and at left side of L5-S1 level (P=0.038). We did not find an association between facet orientation, facet tropism, and spondylolysis. One of the possible explanations for this is that the high prevalence of facet joint

  9. Work orientations in the job demands-resources model

    NARCIS (Netherlands)

    Demerouti, E.; Bakker, A.B.; Fried, Y.

    2012-01-01

    Purpose – This study aims to examine the role of instrumental vs intrinsic work orientations in the job demands-resources (JD-R) model. Design/methodology – Using a sample of 123 employees, the authors investigated longitudinally whether an instrumental work orientation moderates the motivational

  10. Identification and Modelling of the In-Plane Reinforcement Orientation Variations in a CFRP Laminate Produced by Manual Lay-Up

    Science.gov (United States)

    Davila, Yves; Crouzeix, Laurent; Douchin, Bernard; Collombet, Francis; Grunevald, Yves-Henri

    2017-08-01

    Reinforcement angle orientation has a significant effect on the mechanical properties of composite materials. This work presents a methodology to introduce variable reinforcement angles into finite element (FE) models of composite structures. The study of reinforcement orientation variations uses meta-models to identify and control a continuous variation across the composite ply. First, the reinforcement angle is measured through image analysis techniques of the composite plies during the lay-up phase. Image analysis results show that variations in the mean ply orientations are between -0.5 and 0.5° with standard deviations ranging between 0.34 and 0.41°. An automatic post-treatment of the images determines the global and local angle variations yielding good agreements visually and numerically between the analysed images and the identified parameters. A composite plate analysed at the end of the cooling phase is presented as a case of study. Here, the variation in residual strains induced by the variability in the reinforcement orientation are up to 28% of the strain field of the homogeneous FE model. The proposed methodology has shown its capabilities to introduce material and geometrical variability into FE analysis of layered composite structures.

  11. Identification and Modelling of the In-Plane Reinforcement Orientation Variations in a CFRP Laminate Produced by Manual Lay-Up

    Science.gov (United States)

    Davila, Yves; Crouzeix, Laurent; Douchin, Bernard; Collombet, Francis; Grunevald, Yves-Henri

    2018-06-01

    Reinforcement angle orientation has a significant effect on the mechanical properties of composite materials. This work presents a methodology to introduce variable reinforcement angles into finite element (FE) models of composite structures. The study of reinforcement orientation variations uses meta-models to identify and control a continuous variation across the composite ply. First, the reinforcement angle is measured through image analysis techniques of the composite plies during the lay-up phase. Image analysis results show that variations in the mean ply orientations are between -0.5 and 0.5° with standard deviations ranging between 0.34 and 0.41°. An automatic post-treatment of the images determines the global and local angle variations yielding good agreements visually and numerically between the analysed images and the identified parameters. A composite plate analysed at the end of the cooling phase is presented as a case of study. Here, the variation in residual strains induced by the variability in the reinforcement orientation are up to 28% of the strain field of the homogeneous FE model. The proposed methodology has shown its capabilities to introduce material and geometrical variability into FE analysis of layered composite structures.

  12. GRACE manual

    International Nuclear Information System (INIS)

    Ishikawa, T.; Kawabata, S.; Shimizu, Y.; Kaneko, T.; Kato, K.; Tanaka, H.

    1993-02-01

    This manual is composed of three kinds of objects, theoretical background for calculating the cross section of elementary process, usage and technical details of the GRACE system. Throughout this manual we take the tree level process e + e - → W + W - γ as an example, including the e ± -scalar boson interactions. The real FORTRAN source code for this process is attached in the relevant sections as well as the results of calculation, which might be a great help for understanding the practical use of the system. (J.P.N.)

  13. Waste characterization data manual for the inactive liquid low-level waste tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1992-06-01

    This Waste Characterization Data Manual contains the results of an analysis of the contents of liquid low-level waste (LLLW) tanks that have been removed from service in accordance with the requirements of the Oak Ridge Reservation (ORR) Federal Facility Agreement (FFA), Sect. IX.G.1. This manual contains the results of sampling activities that were conducted at the Oak Ridge National Laboratory in 1988. Thirty-three tanks were sampled and analyzed at that time. Sampling of the remaining inactive tanks is currently underway, and data from these tanks will be added to this manual as they become available. Data are presented from analysis of volatile organic compounds, semivolatile organic compounds, polychlorinated biphenyls, radiochemical compounds, and inorganic compounds

  14. Waste characterization data manual for the inactive liquid low-level waste tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    This Waste Characterization Data Manual contains the results of an analysis of the contents of liquid low-level waste (LLLW) tanks that have been removed from service in accordance with the requirements of the Oak Ridge Reservation (ORR) Federal Facility Agreement (FFA), Sect. IX.G.1. This manual contains the results of sampling activities that were conducted at the Oak Ridge National Laboratory in 1988. Thirty-three tanks were sampled and analyzed at that time. Sampling of the remaining inactive tanks is currently underway, and data from these tanks will be added to this manual as they become available. Data are presented from analysis of volatile organic compounds, semivolatile organic compounds, polychlorinated biphenyls, radiochemical compounds, and inorganic compounds.

  15. Environmental sampling accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-06-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an on-line disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished by using computer-generated schedules, collection labels, and output/input cards. For each scheduled sample and analysis, a printed card is issued for collection, laboratory analysis, and counting. The cards also contain information needed by personnel performing the jobs, such as sample location, aliquot to be processed, or procedure number. Manual entries are made on the cards when each step in the process is completed. Additional pertinent data are also manually entered on the cards; e.g., entries are made explaining why a sample is not collected, the sample aliquot in the event a nonstandard aliquot is processed, field measurement results, and analytical results. These manually entered data are keypunched and read into the computer files. The computer files are audited daily, and summaries of samples not processed in pre-established normal time intervals are issued. The progress of sample analyses can also be readily determined at any time using the CRT terminal. Historic data are also maintained on magnetic tape and workload summaries are issued showing the number of samples and number of determinations per month

  16. Partners Plus: Families and Caregivers in Partnerships. A Family-Centered Guide to Respite Care. Trainer's Workshop Manual [and] Community Planning Manual [and] A Family Manual [and] Caregiver Manual.

    Science.gov (United States)

    Ownby, Lisa L.; Hooke, Amanda C.; Moore, Dee Wylie; Garland, Corinne W.; Frank, Adrienne

    Four manuals on implementing the Partners Respite Model, which provides respite care for children with disabilities or chronic illnesses, comprise this document. The Community Planning Manual offers a step-by-step guide to replication of the Partners Respite Model and is divided into sections on developing the Partners program, implementing the…

  17. Preliminary test of remote manual instrumentation & control type system for vacuum unit of 350 KeV / 10 mA electron beam machine

    International Nuclear Information System (INIS)

    Sudiyanto

    2003-01-01

    Remote manual instrumentation & control type for vacuum unit of 350 KeV/10 mA Electron Beam Machine is being completed. The system consisting of a remote manual controlled and a remote acquisition system. A remote manual (50 m) controlled is based on the on/off status of 220 Volt terminal supply for pneumatic valves and vacuum pumps, in this case the power supply switch of pneumatic valves and pumps have already been selected On. Remote acquisition of vacuum level can be done by using a CCTV camera which is place in front of the panning gauge and TGP.300 Balzer unit.The CCTV system equipped with 6 cameras, one TV monitor and a multiplexer unit to arranged a selected picture on it. One of the camera was mounted on the rotator unit, it can be controlled (rotating left / right) for different monitoring orientations required by using infrared controller. A trial test of the remote manual control system for vacuum unit of the Electron Beam Machine showed a good performance. (author)

  18. FRMAC Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Frandsen, K.

    2010-05-01

    In the event of a major radiological incident, the Federal Radiological Monitoring and Assessment Center (FRMAC) will coordinate the federal agencies that have various statutory responsibilities. The FRMAC is responsible for coordinating all environmental radiological monitoring, sampling, and assessment activities for the response. This manual describes the FRMAC’s response activities in a radiological incident. It also outlines how FRMAC fits in the National Incident Management System (NIMS) under the National Response Framework (NRF) and describes the federal assets and subsequent operational activities which provide federal radiological monitoring and assessment of the affected areas. In the event of a potential or existing major radiological incident, the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) is responsible for establishing and managing the FRMAC during the initial phases.

  19. An Experimental Study of Force Involved in Manual Rebar Bending Process

    Science.gov (United States)

    Deepu, Sasi; Vishnu, Rajendran S.; Harish, Mohan T.; Bhavani, Rao R.

    2018-02-01

    The work presents an experimental method of understanding the force applied during a manual rebar bending process. The study tracks the force with the variation of the angle of bend and the elapsed time from the start to the end of a complete manual rebar bending process. A sample of expert rebar bending labourers are used for conducting the experiment and the data processed to set a performance standard. If a simulator based rebar bending training can be provided for a novice, this standard can be used as a matrix to define how close a novice rebar bender is closing to the expertise.

  20. The ISIS Open GENIE user manual

    International Nuclear Information System (INIS)

    Akeroyd, F.A.; Ashworth, R.L.; Campbell, S.I.; Johnston, S.D.; Martin, J.M.; Moreton-Smith, C.M.; Sivia, D.S.

    2000-01-01

    This manual should enable you to become familiar with Open GENIE quickly and easily. It therefore complements the Open GENIE Reference Manual which should be used to understand the full meaning of Open GENIE commands. The reference manual is accessible on the ISIS web server at: http://www.isis.rl.ac.uk/GENIEReferenceManual/ and the user manual is planned to be accessible by January '98 at http://www.isis.rl.ac.ukIGENIEUserManual/. The Open GENIE User Manual is separated into two parts: Part A. The User Manual. An introduction to the use of Open GENIE. Part B. The Installation Guide. General information on how to install and run Open GENIE. Assuming that you are new to Open GENIE and have just downloaded a copy you will need to consult the Installation Guide to get Open GENIE installed on your machine. After this we recommend you experiment with some of the example files to get an idea of the capabilities of Open GENIE. For further information, comments, additions of routines that you feel should be included, please contact us at genie at isise.rl.ac.uk

  1. Handbook of laboratory techniques; Manual de tecnicas de laboratorio

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    The Nuclear Regulatory Authority in Argentina have laboratories of support to regulations functions on radiological and nuclear safety, safeguards and physical protection, that have a surface of 2950 m{sup 2} in the Ezeiza Atomic Center. The manual describes in seven chapters the different techniques developed and applied in the laboratories along four decades of existence. The chapter 1: Dedicated to the treatment of environmental samples, described the procedures associated with the different types of samples: deposits, waters, sediments, vegetables, milk, fish and diet. The chapter 2: Details 48 radiochemical techniques associated to the measurements of americium 241, carbon 16, strontium 90, iodine 129, plutonium, radium 226, radon, uranium, nickel and actinides. The chapter 3: Describes the measurements techniques of alpha and gamma spectrometry. The different techniques of biological and physical dosimetry are described in the chapters 5 and 6 respectively. The final chapter is dedicated the techniques of external and internal contamination. It s important to emphasize that this manual contains the standardized technologies that the Nuclear Regulatory Authority of Argentina submits regularly to international comparisons.

  2. Self-Commissioning for sensorless Field Oriented Control of PM motors

    DEFF Research Database (Denmark)

    Rasmussen, Henrik

    2004-01-01

    currents. Inverter parameters, stator resistance and inductance are measured at stand-still before the initial start-up of the drive. The strength of the permanent magnet is measured during a initial manual start-up of the drive. The measured parameters are used in a field oriented control system......Methods for estimation of the parameters in the inverter and the PM motor, based on special designed experiments, are given. Input to the system is the reference values for the stator voltages given as duty cycles for the Pulse With Modulated power device. The system output is the measured stator...

  3. Self-commisioning for Sensorless Field Oriented Control of PM Motors

    DEFF Research Database (Denmark)

    Rasmussen, Henrik

    2004-01-01

    currents. Inverter parameters, stator resistance and inductance are measured at stand-still before the initial start-up of the drive. The strength of the permanent magnet is measured during a initial manual start-up of the drive. The measured parameters are used in a field oriented control system......Methods for estimation of the parameters in the inverter and the PM motor, based on special designed experiments, are given. Input to the system is the reference values for the stator voltages given as duty cycles for the Pulce With Modulated power device. The system output is the measured stator...

  4. Self-commissioning for sensorless Field Oriented Control of PM Motors

    DEFF Research Database (Denmark)

    Rasmussen, Henrik

    2004-01-01

    currents. Inverter parameters, stator resistance and inductance are measured at stand-still before the initial start-up of the drive. The strength of the permanent magnet is measured during a initial manual start-up of the drive. The measured parameters are used in a field oriented control system......Methods for estimation of the parameters in the inverter and the PM motor, based on special designed experiments, are given. Input to the system is the reference values for the stator voltages given as duty cycles for the Pulse With Modulated power device. The system output is the measured stator...

  5. The operation and maintenance manual

    International Nuclear Information System (INIS)

    Stoll, A.; Krotil, H.; Klein, W.

    1976-01-01

    The operating manual is one of many technical documents which the nuclear power plant operator needs for ensuring safe operation. For the operating staff, however, there is only one document, namely the operating manual. The operating manual is an essential element in bringing man and machine in harmony. This is necessary for safe and, as far as possible, uninterrupted operation of the power plant. The operating manual is the only document containing binding instructions for plant operation. All the tasks of plant operation which are carried out by plant staff are described in the operating manual in a form which is as clear and comprehensible as possible. A considerable number of these tasks can only be carried out by man, namely: 1) tasks concerning operational organization, 2) all non-automated areas of plant operation. (orig./TK) [de

  6. Fire Protection Program Manual

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2012-05-18

    This manual documents the Lawrence Livermore National Laboratory (LLNL) Fire Protection Program. Department of Energy (DOE) Orders 420.1B, Facility Safety, requires LLNL to have a comprehensive and effective fire protection program that protects LLNL personnel and property, the public and the environment. The manual provides LLNL and its facilities with general information and guidance for meeting DOE 420.1B requirements. The recommended readers for this manual are: fire protection officers, fire protection engineers, fire fighters, facility managers, directorage assurance managers, facility coordinators, and ES and H team members.

  7. Electronic manual of the nuclear characteristics analysis code-set for FBR

    International Nuclear Information System (INIS)

    Makino, Tohru

    2001-03-01

    Reactor Physics Gr., System Engineering Technology Division, O-arai Engineering Center has consolidated the nuclear design database to improve analytical methods and prediction accuracy for large fast breeder cores such as demonstration or commercial FBRs from the previous research. The up-to-date information about usage of the nuclear characteristics analysis code-set was compiled as a part of the improvement of basic design data base for FBR core. The outlines of the electronic manual are as follows; (1) The electronic manual includes explanations of following codes: JOINT : Code Interface Program. SLAROM, CASUP : Effective Cross Section Calculation Code. CITATION-FBR : Diffusion Analysis Code. PERKY : Perturbative Diffusion Analysis Code. SNPERT, SNPERT-3D : Perturbative Transport Analysis Code. SAGEP, SAGEP-3D : Sensitivity Coefficient Calculation Code. NSHEX : Transport Analysis Code using Nodal Method. ABLE : Cross Section Adjustment Calculation Code. ACCEPT : Predicting Accuracy Evaluation Code. (2) The electronic manual is described using HTML file format and PDF file for easy maintenance, updating and for easy referring through JNC Intranet. User can refer manual pages by usual Web browser software without any special setup. (3) Many of manual pages include link-tags to jump to related pages. String search is available in both HTML and PDF documents. (4) User can download source code, sample input data and shell script files to carry out each analysis from download page of each code (JNC inside only). (5) Usage of the electronic manual and maintenance/updating process are described in this report and it makes possible to enroll new code or new information in the electronic manual. Since the information has been taken into account about modifications and error fixings, added to each code after the last consolidation in 1994, the electronic manual would cover most recent status of the nuclear characteristics analysis code-set. One of other advantages of use

  8. Automatic Semantic Orientation of Adjectives for Indonesian Language Using PMI-IR and Clustering

    Science.gov (United States)

    Riyanti, Dewi; Arif Bijaksana, M.; Adiwijaya

    2018-03-01

    We present our work in the area of sentiment analysis for Indonesian language. We focus on bulding automatic semantic orientation using available resources in Indonesian. In this research we used Indonesian corpus that contains 9 million words from kompas.txt and tempo.txt that manually tagged and annotated with of part-of-speech tagset. And then we construct a dataset by taking all the adjectives from the corpus, removing the adjective with no orientation. The set contained 923 adjective words. This systems will include several steps such as text pre-processing and clustering. The text pre-processing aims to increase the accuracy. And finally clustering method will classify each word to related sentiment which is positive or negative. With improvements to the text preprocessing, can be achieved 72% of accuracy.

  9. ARS-Media for excel instruction manual

    Science.gov (United States)

    ARS-Media for Excel Instruction Manual is the instruction manual that explains how to use the Excel spreadsheet ARS-Media for Excel application. ARS-Media for Excel Instruction Manual is provided as a pdf file....

  10. Examining weight and eating behavior by sexual orientation in a sample of male veterans.

    Science.gov (United States)

    Bankoff, Sarah M; Richards, Lauren K; Bartlett, Brooke; Wolf, Erika J; Mitchell, Karen S

    2016-07-01

    Eating disorders are understudied in men and in sexual minority populations; however, extant evidence suggests that gay men have higher rates of disordered eating than heterosexual men. The present study examined the associations between sexual orientation, body mass index (BMI), disordered eating behaviors, and food addiction in a sample of male veterans. Participants included 642 male veterans from the Knowledge Networks-GfK Research Panel. They were randomly selected from a larger study based on previously reported trauma exposure; 96% identified as heterosexual. Measures included the Eating Disorder Diagnostic Scale, the Yale Food Addiction Scale, and self-reported height and weight. Heterosexual and sexual minority men did not differ significantly in terms of BMI. However, gay and bisexual men (n=24) endorsed significantly greater eating disorder symptoms and food addiction compared to heterosexual men. Our findings that sexual minority male veterans may be more likely to experience eating disorder and food addiction symptoms compared to heterosexual male veterans highlight the importance of prevention, assessment, and treatment efforts targeted to this population. Published by Elsevier Inc.

  11. Salinas : theory manual.

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Timothy Francis; Reese, Garth M.; Bhardwaj, Manoj Kumar

    2011-11-01

    Salinas provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Salinas. For a more detailed description of how to use Salinas, we refer the reader to Salinas, User's Notes. Many of the constructs in Salinas are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Salinas are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature.

  12. Determination of Residual Chlorine and Turbidity in Drinking Water. Student Manual.

    Science.gov (United States)

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This student's manual covers analytical methods for residual chlorine and turbidity. Topics include sample handling, permissable concentration levels, substitution of residual chlorine for bacteriological work, public notification, and the required analytical techniques to determine residual chlorine and turbidity. The publication is intended for…

  13. Effectiveness of experimental system in children’s mastering of main manual motor skills

    Directory of Open Access Journals (Sweden)

    L. L. Galamandjuk

    2015-07-01

    Full Text Available Purpose: determine effectiveness of simulated system of pre-school age children motor functioning’s preventive development for mastering of main movements for manual skills. Material: in the research five years’ children (control group n=150 and experimental group n=120 participated. Results: it was determined that transition from uncomfortable to comfortable for a child conditions of exercises’ fulfillment facilitates quicker formation of required motor program. It is connected with the fact that, independent on orientation of manual motor asymmetry progressing of semi-spheres’ interaction takes place. This interaction is an important condition of increasing of child functioning’s effectiveness in different aspects. Achievement of such result was also facilitated by physical exercises, which children practiced at home. Functioning of physical culture instructor and kindergarten teachers was also important: they formed parents’ conscious position concerning importance of such trainings; recommended effective means and methods. Conclusions: application of the offered system ensures much better result than traditional approach to this problem. It is one of keys to prevention of negative tendencies in development of pre-school age children.

  14. Improved sampling and analysis of images in corneal confocal microscopy.

    Science.gov (United States)

    Schaldemose, E L; Fontain, F I; Karlsson, P; Nyengaard, J R

    2017-10-01

    Corneal confocal microscopy (CCM) is a noninvasive clinical method to analyse and quantify corneal nerve fibres in vivo. Although the CCM technique is in constant progress, there are methodological limitations in terms of sampling of images and objectivity of the nerve quantification. The aim of this study was to present a randomized sampling method of the CCM images and to develop an adjusted area-dependent image analysis. Furthermore, a manual nerve fibre analysis method was compared to a fully automated method. 23 idiopathic small-fibre neuropathy patients were investigated using CCM. Corneal nerve fibre length density (CNFL) and corneal nerve fibre branch density (CNBD) were determined in both a manual and automatic manner. Differences in CNFL and CNBD between (1) the randomized and the most common sampling method, (2) the adjusted and the unadjusted area and (3) the manual and automated quantification method were investigated. The CNFL values were significantly lower when using the randomized sampling method compared to the most common method (p = 0.01). There was not a statistical significant difference in the CNBD values between the randomized and the most common sampling method (p = 0.85). CNFL and CNBD values were increased when using the adjusted area compared to the standard area. Additionally, the study found a significant increase in the CNFL and CNBD values when using the manual method compared to the automatic method (p ≤ 0.001). The study demonstrated a significant difference in the CNFL values between the randomized and common sampling method indicating the importance of clear guidelines for the image sampling. The increase in CNFL and CNBD values when using the adjusted cornea area is not surprising. The observed increases in both CNFL and CNBD values when using the manual method of nerve quantification compared to the automatic method are consistent with earlier findings. This study underlines the importance of improving the analysis of the

  15. TJ-II Library Manual (Version 2)

    International Nuclear Information System (INIS)

    Tribaldos, V.; Milligen, B. Ph. van; Lopez-Fraguas, A.

    2001-01-01

    This is a manual of use of the TJ2 Numerical Library that has been developed for making numerical computations of different TJ-II configurations. This manual is a new version of the earlier manual CIEMAT report 806. (Author)

  16. Structure, deformation, and failure of flow-oriented semicrystalline polymers

    NARCIS (Netherlands)

    Schrauwen, B.A.G.; Breemen, van L.C.A.; Spoelstra, A.B.; Govaert, L.E.; Peters, G.W.M.; Meijer, H.E.H.

    2004-01-01

    This study deals with the influence of processing induced crystalline orientation on the macroscopic deformation and failure behavior of thin samples of polyethylene and polypropylene. Distribution and structure of flow-induced orientations were characterized by optical microscopy, X-ray diffraction

  17. The effects of violence exposure on the development of impulse control and future orientation across adolescence and early adulthood: Time-specific and generalized effects in a sample of juvenile offenders.

    Science.gov (United States)

    Monahan, Kathryn C; King, Kevin M; Shulman, Elizabeth P; Cauffman, Elizabeth; Chassin, Laurie

    2015-11-01

    Impulse control and future orientation increase across adolescence, but little is known about how contextual factors shape the development of these capacities. The present study investigates how stress exposure, operationalized as exposure to violence, alters the developmental pattern of impulse control and future orientation across adolescence and early adulthood. In a sample of 1,354 serious juvenile offenders, higher exposure to violence was associated with lower levels of future orientation at age 15 and suppressed development of future orientation from ages 15 to 25. Increases in witnessing violence or victimization were linked to declines in impulse control 1 year later, but only during adolescence. Thus, beyond previous experiences of exposure to violence, witnessing violence and victimization during adolescence conveys unique risk for suppressed development of self-regulation.

  18. Early Childhood Longitudinal Study, Kindergarten Class of 1998-99 (ECLS-K): Combined User's Manual for the ECLS-K Eighth-Grade and K-8 Full Sample Data Files and Electronic Codebooks. NCES 2009-004

    Science.gov (United States)

    Tourangeau, Karen; Nord, Christine; Le, Thanh; Sorongon, Alberto G.; Najarian, Michelle

    2009-01-01

    This manual provides guidance and documentation for users of the eighth-grade data of the Early Childhood Longitudinal Study, Kindergarten Class of 1998-99 (ECLS-K). It begins with an overview of the ECLS-K study. Subsequent chapters provide details on the instruments and measures used, the sample design, weighting procedures, response rates, data…

  19. Modification of Otolith-Ocular Reflexes, Motion Perception and Manual Control During Variable Radius Centrifugation Following Space Flight

    Science.gov (United States)

    Wood, Scott J.; Clarke, A. H.; Rupert, A. H.; Harm, D. L.; Clement, G. R.

    2009-01-01

    Two joint ESA-NASA studies are examining changes in otolith-ocular reflexes and motion perception following short duration space flights, and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. Data is currently being collected on astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation is utilized to elicit otolith reflexes in the lateral plane without concordant roll canal cues. Unilateral centrifugation (400 deg/s, 3.5 cm radius) stimulates one otolith positioned off-axis while the opposite side is centered over the axis of rotation. During this paradigm, roll-tilt perception is measured using a subjective visual vertical task and ocular counter-rolling is obtained using binocular video-oculography. During a second paradigm (216 deg/s, less than 20 cm radius), the effects of stimulus frequency (0.15 - 0.6 Hz) are examined on eye movements and motion perception. A closed-loop nulling task is also performed with and without vibrotactile display feedback of chair radial position. Data collection is currently ongoing. Results to date suggest there is a trend for perceived tilt and translation amplitudes to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. One result of this study will be to characterize the variability (gain, asymmetry) in both otolith-ocular responses and motion perception during variable radius centrifugation, and measure the time course of post-flight recovery. This study will also address how adaptive changes in otolith-mediated reflexes correspond to one's ability to perform closed-loop nulling tasks following G-transitions, and whether manual control performance can be improved

  20. Health Orientation, Knowledge, and Attitudes toward Genetic Testing and Personalized Genomic Services: Preliminary Data from an Italian Sample

    Directory of Open Access Journals (Sweden)

    Serena Oliveri

    2016-01-01

    Full Text Available Objective. The study aims at assessing personality tendencies and orientations that could be closely correlated with knowledge, awareness, and interest toward undergoing genetic testing. Methods. A sample of 145 subjects in Italy completed an online survey, investigating demographic data, health orientation, level of perceived knowledge about genetic risk, genetic screening, and personal attitudes toward direct to consumer genetic testing (DTCGT. Results. Results showed that respondents considered genetic assessment to be helpful for disease prevention, but they were concerned that results could affect their life planning with little clinical utility. Furthermore, a very high percentage of respondents (67% had never heard about genetic testing directly available to the public. Data showed that personality tendencies, such as personal health consciousness, health internal control, health esteem, and confidence, motivation to avoid unhealthiness and motivation for healthiness affected the uptake of genetic information and the interest in undergoing genetic testing. Conclusions. Public knowledge and attitudes toward genetic risk and genetic testing among European countries, along with individual personality and psychological tendencies that could affect these attitudes, remain unexplored. The present study constitutes one of the first attempts to investigate how such personality tendencies could motivation to undergo genetic testing and engagement in lifestyle changes.

  1. GERTS GQ User's Manual.

    Science.gov (United States)

    Akiba, Y.; And Others

    This user's manual for the simulation program Graphical Evaluation and Review Technique (GERT) GQ contains sections on nodes, branches, program input description and format, and program output, as well as examples. Also included is a programmer's manual which contains information on scheduling, subroutine descriptions, COMMON Variables, and…

  2. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    Science.gov (United States)

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  3. Within-Group Differences in Sexual Orientation and Identity

    Science.gov (United States)

    Worthington, Roger L.; Reynolds, Amy L.

    2009-01-01

    The purpose of this investigation was to examine within-group differences among self-identified sexual orientation and identity groups. To understand these within-group differences, 2 types of analysis were conducted. First, a sample of 2,732 participants completed the Sexual Orientation and Identity Scale. Cluster analyses were used to identify 3…

  4. The Effect of Pneumatic Tube Systems on the Hemolysis of Biochemistry Blood Samples.

    Science.gov (United States)

    Cakirca, Gokhan; Erdal, Huseyin

    2017-05-01

    Pneumatic tube systems (PTSs) are widely used in many hospitals because they lead to reduced turnaround times and cost efficiency. However, PTSs may affect the quality of the blood samples transported to the laboratory. The aim of this study was to investigate the effect of the PTS used in our hospital on the hemolysis of the biochemical blood samples transported to the laboratory. A total of 148 samples were manually transported to the laboratory by hospital staff, 148 samples were transported with the PTS, and 113 were transported with the PTS without use of sponge-rubber inserts (PTSws). Hemolysis rates and the levels of biochemical analytes for the different transportation methods were compared. No significant difference was found between the samples transported manually and with the PTS with regard to hemolysis rate and the levels of biochemical analytes. However, the samples transported with the PTSws showed a significant difference compared with the samples transported manually and with the PTS with regard to hemolysis rate and potassium and lactate dehydrogenase levels. The percentages of the samples that exceeded the permissible threshold for the hemolysis among the samples transported manually, with the PTS, and with the PTSws were 10%, 8%, and 47%, respectively. A PTS can be used safely for transporting biochemistry blood samples to the laboratory. However, a sponge-rubber insert that holds sample tubes must be used with the PTS to prevent the hemolysis of blood samples. Copyright © 2016 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  5. 14 CFR 121.141 - Airplane flight manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane flight manual. 121.141 Section 121... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Manual Requirements § 121.141 Airplane flight manual. (a) Each certificate holder shall keep a current approved airplane flight manual for each type of...

  6. A Model of Parental Achievement-Oriented Psychological Control in Academically Gifted Students

    Science.gov (United States)

    Garn, Alex C.; Jolly, Jennifer L.

    2015-01-01

    This study investigated achievement-oriented parent socialization as it pertains to school avoidance in a sample of gifted students. A serial mediation model examining relationships among parental achievement-oriented psychological control (APC), fear of academic failure, academic amotivation, and school avoidance was tested. The sample included…

  7. Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nuclearmalaysia.gov.my; Yussup, Nolida; Ibrahim, Maslina Bt. Mohd; Mokhtar, Mukhlis B.; Soh Shaari, Syirrazie Bin Che; Azman, Azraf B. [Technical Support Division, Malaysian Nuclear Agency, 43000, Kajang, Selangor (Malaysia); Salim, Nazaratul Ashifa Bt. Abdullah [Division of Waste and Environmental Technology, Malaysian Nuclear Agency, 43000, Kajang, Selangor (Malaysia); Ismail, Nadiah Binti [Fakulti Kejuruteraan Elektrik, UiTM Pulau Pinang, 13500 Permatang Pauh, Pulau Pinang (Malaysia)

    2015-04-29

    Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on ‘Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)’. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

  8. Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

    Science.gov (United States)

    Rahman, Nur Aira Abd; Yussup, Nolida; Salim, Nazaratul Ashifa Bt. Abdullah; Ibrahim, Maslina Bt. Mohd; Mokhtar, Mukhlis B.; Soh@Shaari, Syirrazie Bin Che; Azman, Azraf B.; Ismail, Nadiah Binti

    2015-04-01

    Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on `Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)'. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

  9. Writing for Distance Education. Samples Booklet.

    Science.gov (United States)

    International Extension Coll., Cambridge (England).

    Approaches to the format, design, and layout of printed instructional materials for distance education are illustrated in 36 samples designed to accompany the manual, "Writing for Distance Education." Each sample is presented on a single page with a note pointing out its key features. Features illustrated include use of typescript layout, a comic…

  10. Neighborhood resolved fiber orientation distributions (NRFOD) in automatic labeling of white matter fiber pathways.

    Science.gov (United States)

    Ugurlu, Devran; Firat, Zeynep; Türe, Uğur; Unal, Gozde

    2018-05-01

    Accurate digital representation of major white matter bundles in the brain is an important goal in neuroscience image computing since the representations can be used for surgical planning, intra-patient longitudinal analysis and inter-subject population connectivity studies. Reconstructing desired fiber bundles generally involves manual selection of regions of interest by an expert, which is subject to user bias and fatigue, hence an automation is desirable. To that end, we first present a novel anatomical representation based on Neighborhood Resolved Fiber Orientation Distributions (NRFOD) along the fibers. The resolved fiber orientations are obtained by generalized q-sampling imaging (GQI) and a subsequent diffusion decomposition method. A fiber-to-fiber distance measure between the proposed fiber representations is then used in a density-based clustering framework to select the clusters corresponding to the major pathways of interest. In addition, neuroanatomical priors are utilized to constrain the set of candidate fibers before density-based clustering. The proposed fiber clustering approach is exemplified on automation of the reconstruction of the major fiber pathways in the brainstem: corticospinal tract (CST); medial lemniscus (ML); middle cerebellar peduncle (MCP); inferior cerebellar peduncle (ICP); superior cerebellar peduncle (SCP). Experimental results on Human Connectome Project (HCP)'s publicly available "WU-Minn 500 Subjects + MEG2 dataset" and expert evaluations demonstrate the potential of the proposed fiber clustering method in brainstem white matter structure analysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Perceived Sexual Orientation Based on Vocal and Facial Stimuli Is Linked to Self-Rated Sexual Orientation in Czech Men

    Science.gov (United States)

    Valentova, Jaroslava Varella; Havlíček, Jan

    2013-01-01

    Previous research has shown that lay people can accurately assess male sexual orientation based on limited information, such as face, voice, or behavioral display. Gender-atypical traits are thought to serve as cues to sexual orientation. We investigated the presumed mechanisms of sexual orientation attribution using a standardized set of facial and vocal stimuli of Czech men. Both types of stimuli were rated for sexual orientation and masculinity-femininity by non-student heterosexual women and homosexual men. Our data showed that by evaluating vocal stimuli both women and homosexual men can judge sexual orientation of the target men in agreement with their self-reported sexual orientation. Nevertheless, only homosexual men accurately attributed sexual orientation of the two groups from facial images. Interestingly, facial images of homosexual targets were rated as more masculine than heterosexual targets. This indicates that attributions of sexual orientation are affected by stereotyped association between femininity and male homosexuality; however, reliance on such cues can lead to frequent misjudgments as was the case with the female raters. Although our study is based on a community sample recruited in a non-English speaking country, the results are generally consistent with the previous research and thus corroborate the validity of sexual orientation attributions. PMID:24358180

  12. Perceived sexual orientation based on vocal and facial stimuli is linked to self-rated sexual orientation in Czech men.

    Directory of Open Access Journals (Sweden)

    Jaroslava Varella Valentova

    Full Text Available Previous research has shown that lay people can accurately assess male sexual orientation based on limited information, such as face, voice, or behavioral display. Gender-atypical traits are thought to serve as cues to sexual orientation. We investigated the presumed mechanisms of sexual orientation attribution using a standardized set of facial and vocal stimuli of Czech men. Both types of stimuli were rated for sexual orientation and masculinity-femininity by non-student heterosexual women and homosexual men. Our data showed that by evaluating vocal stimuli both women and homosexual men can judge sexual orientation of the target men in agreement with their self-reported sexual orientation. Nevertheless, only homosexual men accurately attributed sexual orientation of the two groups from facial images. Interestingly, facial images of homosexual targets were rated as more masculine than heterosexual targets. This indicates that attributions of sexual orientation are affected by stereotyped association between femininity and male homosexuality; however, reliance on such cues can lead to frequent misjudgments as was the case with the female raters. Although our study is based on a community sample recruited in a non-English speaking country, the results are generally consistent with the previous research and thus corroborate the validity of sexual orientation attributions.

  13. Oil Spill Response Manual

    NARCIS (Netherlands)

    Marieke Zeinstra; Sandra Heins; Wierd Koops

    2014-01-01

    A two year programme has been carried out by the NHL University of Applied Sciences together with private companies in the field of oil and chemical spill response to finalize these manuals on oil and chemical spill response. These manuals give a good overview of all aspects of oil and chemical

  14. Evaluation of Manual Ultrasonic Examinations Applied to Detect Flaws in Primary System Dissimilar Metal Welds at North Anna Power Station

    International Nuclear Information System (INIS)

    Anderson, Michael T.; Diaz, Aaron A.; Doctor, Steven R.

    2012-01-01

    During a recent inservice inspection (ISI) of a dissimilar metal weld (DMW) in an inlet (hot leg) steam generator nozzle at North Anna Power Station Unit 1, several axially oriented flaws went undetected by the licensee's manual ultrasonic testing (UT) technique. The flaws were subsequently detected as a result of outside diameter (OD) surface machining in preparation for a full structural weld overlay. The machining operation uncovered the existence of two through-wall flaws, based on the observance of primary water leaking from the DMW. Further ultrasonic tests were then performed, and a total of five axially oriented flaws, classified as primary water stress corrosion cracking (PWSCC), were detected in varied locations around the weld circumference.

  15. 46 CFR 160.176-21 - User manuals.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false User manuals. 160.176-21 Section 160.176-21 Shipping...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Inflatable Lifejackets § 160.176-21 User manuals. (a) The manufacturer must develop a user's manual for each model of inflatable lifejacket. The content of the manual...

  16. US Department of Energy radiological control manual

    International Nuclear Information System (INIS)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements

  17. Operating manual for the emission spectrometer NOI-6e for laboratory use; Manual de operacion de manejo del espectrometro de emision NOI-6e para uso de laboratorio

    Energy Technology Data Exchange (ETDEWEB)

    Albornoz G, M P

    1993-08-01

    This manual describes graphically and specifically how to operate the Emission Spectrometer NOI-6e. Detailed instructions are given for everything form turning on the equipment, quality control of several parameters, calibration, sample analysis; measurements and obtaining final results form the microprocessors. (author).

  18. Manual hyperinflation and the role of physical therapy in intensive care and emergency units

    Directory of Open Access Journals (Sweden)

    Rafael Vinícius Santos Cruz

    Full Text Available Abstract Introduction: Although manual hyperinflation (MHI is a physical therapy technique commonly used in intensive care and emergency units, there is little consensus about its use. Objective: To investigate the knowledge of physical therapists working in intensive care and emergency units about manual hyperinflation. Methods: Data were collected through self-administered questionnaires on manual hyperinflation. Data collection took place between September 2014 and January 2015, in Itabuna and Ilhéus, Bahia, Brazil. Results: The study sample was composed of 32 physical therapists who had between 4 months and 10 years working experience. All respondents affirmed that they used the technique in their professional practice. However, only 34.4% reported it to be a routine practice. 90.6% stated that the most common patient position during manual hyperinflation is “supine”. Participants were almost unanimous (93.8% in citing secretion removal and cough stimulation as perceived benefits of MHI. High peak airway pressure was identified as being a precaution to treatment with MHI by 84.4% of participants, whilst 100% of the sample agreed that an undrained pneumothorax was a contraindication to MHI. Conclusion: The most common answers to the questionnaire were: supine position during MHI; secretion removal and cough stimulation as perceived benefits; high peak airway pressure as a precaution; and an undrained pneumothorax as a contraindication.

  19. Technical Manual: 2002 Series GED Tests

    Science.gov (United States)

    Ezzelle, Carol; Setzer, J. Carl

    2009-01-01

    This manual was written to provide technical information regarding the 2002 Series GED (General Educational Development) Tests. Throughout this manual, documentation is provided regarding the development of the GED Tests, data collection activities, as well as reliability and validity evidence. The purpose of this manual is to provide evidence…

  20. A comparison of coronal mass ejections identified by manual and automatic methods

    Directory of Open Access Journals (Sweden)

    S. Yashiro

    2008-10-01

    Full Text Available Coronal mass ejections (CMEs are related to many phenomena (e.g. flares, solar energetic particles, geomagnetic storms, thus compiling of event catalogs is important for a global understanding these phenomena. CMEs have been identified manually for a long time, but in the SOHO era, automatic identification methods are being developed. In order to clarify the advantage and disadvantage of the manual and automatic CME catalogs, we examined the distributions of CME properties listed in the CDAW (manual and CACTus (automatic catalogs. Both catalogs have a good agreement on the wide CMEs (width>120° in their properties, while there is a significant discrepancy on the narrow CMEs (width≤30°: CACTus has a larger number of narrow CMEs than CDAW. We carried out an event-by-event examination of a sample of events and found that the CDAW catalog have missed many narrow CMEs during the solar maximum. Another significant discrepancy was found on the fast CMEs (speed>1000 km/s: the majority of the fast CDAW CMEs are wide and originate from low latitudes, while the fast CACTus CMEs are narrow and originate from all latitudes. Event-by-event examination of a sample of events suggests that CACTus has a problem on the detection of the fast CMEs.

  1. Technical Manual. The ACT®

    Science.gov (United States)

    ACT, Inc., 2014

    2014-01-01

    This manual contains technical information about the ACT® college readiness assessment. The principal purpose of this manual is to document the technical characteristics of the ACT in light of its intended purposes. ACT regularly conducts research as part of the ongoing formative evaluation of its programs. The research is intended to ensure that…

  2. Technical Report and Data File User's Manual for the 1992 National Adult Literacy Survey.

    Science.gov (United States)

    Kirsch, Irwin; Yamamoto, Kentaro; Norris, Norma; Rock, Donald; Jungeblut, Ann; O'Reilly, Patricia; Berlin, Martha; Mohadjer, Leyla; Waksberg, Joseph; Goksel, Huseyin; Burke, John; Rieger, Susan; Green, James; Klein, Merle; Campbell, Anne; Jenkins, Lynn; Kolstad, Andrew; Mosenthal, Peter; Baldi, Stephane

    Chapter 1 of this report and user's manual describes design and implementation of the 1992 National Adult Literacy Survey (NALS). Chapter 2 reviews stages of sampling for national and state survey components; presents weighted and unweighted response rates for the household component; and describes non-incentive and prison sample designs. Chapter…

  3. Dakota, a multilevel parallel object-oriented framework for design optimization, parameter estimation, uncertainty quantification, and sensitivity analysis :

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Brian M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ebeida, Mohamed Salah [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Eldred, Michael S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jakeman, John Davis [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Swiler, Laura Painton [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stephens, John Adam [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vigil, Dena M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wildey, Timothy Michael [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bohnhoff, William J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Eddy, John P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hu, Kenneth T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dalbey, Keith R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bauman, Lara E [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hough, Patricia Diane [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-05-01

    The Dakota (Design Analysis Kit for Optimization and Terascale Applications) toolkit provides a exible and extensible interface between simulation codes and iterative analysis methods. Dakota contains algorithms for optimization with gradient and nongradient-based methods; uncertainty quanti cation with sampling, reliability, and stochastic expansion methods; parameter estimation with nonlinear least squares methods; and sensitivity/variance analysis with design of experiments and parameter study methods. These capabilities may be used on their own or as components within advanced strategies such as surrogate-based optimization, mixed integer nonlinear programming, or optimization under uncertainty. By employing object-oriented design to implement abstractions of the key components required for iterative systems analyses, the Dakota toolkit provides a exible and extensible problem-solving environment for design and performance analysis of computational models on high performance computers. This report serves as a user's manual for the Dakota software and provides capability overviews and procedures for software execution, as well as a variety of example studies.

  4. Environment, safety, and health manual, closeout report

    International Nuclear Information System (INIS)

    1975-12-01

    A coordination draft of the Environment, Safety, and Health (ES and H) manual was submitted on 2 September 1975. Comments provided by Operational Safety personnel were being incorporated by a task team when the effort was terminated on 31 October 1975. This report documents the development history of the manual and provides a status of the manual up to the time the efforts were discontinued. Also discussed are issues which effect completion of the manual. Additionally a plan for completion of the manual is suggested

  5. Motion Perception and Manual Control Performance During Passive Tilt and Translation Following Space Flight

    Science.gov (United States)

    Clement, Gilles; Wood, Scott J.

    2010-01-01

    This joint ESA-NASA study is examining changes in motion perception following Space Shuttle flights and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data has been collected on 5 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s) combined with body translation (12-22 cm, peak-to-peak) is utilized to elicit roll-tilt perception (equivalent to 20 deg, peak-to-peak). A forward-backward moving sled (24-390 cm, peak-to-peak) with or without chair tilting in pitch is utilized to elicit pitch tilt perception (equivalent to 20 deg, peak-to-peak). These combinations are elicited at 0.15, 0.3, and 0.6 Hz for evaluating the effect of motion frequency on tilt-translation ambiguity. In both devices, a closed-loop nulling task is also performed during pseudorandom motion with and without vibrotactile feedback of tilt. All tests are performed in complete darkness. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for translation motion perception to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. The results of this study indicate that post-flight recovery of motion perception and manual control performance is complete within 8 days following short-duration space missions. Vibrotactile feedback of tilt improves manual control performance both before and after flight.

  6. Valid and efficient manual estimates of intracranial volume from magnetic resonance images

    International Nuclear Information System (INIS)

    Klasson, Niklas; Olsson, Erik; Rudemo, Mats; Eckerström, Carl; Malmgren, Helge; Wallin, Anders

    2015-01-01

    Manual segmentations of the whole intracranial vault in high-resolution magnetic resonance images are often regarded as very time-consuming. Therefore it is common to only segment a few linearly spaced intracranial areas to estimate the whole volume. The purpose of the present study was to evaluate how the validity of intracranial volume estimates is affected by the chosen interpolation method, orientation of the intracranial areas and the linear spacing between them. Intracranial volumes were manually segmented on 62 participants from the Gothenburg MCI study using 1.5 T, T 1 -weighted magnetic resonance images. Estimates of the intracranial volumes were then derived using subsamples of linearly spaced coronal, sagittal or transversal intracranial areas from the same volumes. The subsamples of intracranial areas were interpolated into volume estimates by three different interpolation methods. The linear spacing between the intracranial areas ranged from 2 to 50 mm and the validity of the estimates was determined by comparison with the entire intracranial volumes. A progressive decrease in intra-class correlation and an increase in percentage error could be seen with increased linear spacing between intracranial areas. With small linear spacing (≤15 mm), orientation of the intracranial areas and interpolation method had negligible effects on the validity. With larger linear spacing, the best validity was achieved using cubic spline interpolation with either coronal or sagittal intracranial areas. Even at a linear spacing of 50 mm, cubic spline interpolation on either coronal or sagittal intracranial areas had a mean absolute agreement intra-class correlation with the entire intracranial volumes above 0.97. Cubic spline interpolation in combination with linearly spaced sagittal or coronal intracranial areas overall resulted in the most valid and robust estimates of intracranial volume. Using this method, valid ICV estimates could be obtained in less than five

  7. Water sample-collection and distribution system

    Science.gov (United States)

    Brooks, R. R.

    1978-01-01

    Collection and distribution system samples water from six designated stations, filtered if desired, and delivers it to various analytical sensors. System may be controlled by Water Monitoring Data Acquisition System or operated manually.

  8. Social orientation, sexual role, and moral judgment: a comparison of two brazilian and one norwegian sample / Orientação social, papel sexual e julgamento moral: uma comparação entre duas amostras brasileiras e uma norueguesa

    Directory of Open Access Journals (Sweden)

    Angela Biaggio

    2005-01-01

    Full Text Available Thirty female and 30 male university students each from Joao Pessoa and Porto Alegre were compared to a comparable Norwegian sample of 60 female and 60 male students. Except for a suggestion of differences in women's cultural orientation, comparisons on Gibbs' test of justice morality, the ECI test for ethic of care, Bem's sex role inventory, and Triandis' test for cultural orientations showed that all differences were between the Norwegian sample and the Brazilian samples as a unit. Brazilians showed a differentiation of sex roles, which was not shown in Norwegians, and higher scores on the collectivism cultural orientation. Norwegians showed higher scores ECI, which might be because of a culture bias in the test. No difference was shown for individualism cultural orientation, and on Gibbs' test. Men scored higher on the total individualism measure, and women on vertical collectivism. JP women scored as more hedonistic and individual than the PA women, who scores as more traditional than the JP women.

  9. DIMAC program user's manual

    International Nuclear Information System (INIS)

    Lee, Byoung Oon; Song, Tae Young

    2003-11-01

    DIMAC (A DIspersion Metallic fuel performance Analysis Code) is a computer program for simulating the behavior of dispersion fuel rods under normal operating conditions of HYPER. It computes the one-dimensional temperature distribution and the thermo-mechanical characteristics of fuel rod under the steady state operation condition, including the swelling and rod deformation. DIMAC was developed based on the experience of research reactor fuel. DIMAC consists of the temperature calculation module, the mechanical swelling calculation module, and the fuel deformation calculation module in order to predict the deformation of a dispersion fuel as a function of power history. Because there are a little of available U-TRU-Zr or TRU-Zr characteristics, the material data of U-Pu-Zr or Pu-Zr are used for those of U-TRU-Zr or TRU-Zr. This report is mainly intended as a user's manual for the DIMAC code. The general description on this code, the description on input parameter, the description on each subroutine, the sample problem and the sample input and partial output are written in this report

  10. DIMAC program user's manual

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byoung Oon; Song, Tae Young

    2003-11-01

    DIMAC (A DIspersion Metallic fuel performance Analysis Code) is a computer program for simulating the behavior of dispersion fuel rods under normal operating conditions of HYPER. It computes the one-dimensional temperature distribution and the thermo-mechanical characteristics of fuel rod under the steady state operation condition, including the swelling and rod deformation. DIMAC was developed based on the experience of research reactor fuel. DIMAC consists of the temperature calculation module, the mechanical swelling calculation module, and the fuel deformation calculation module in order to predict the deformation of a dispersion fuel as a function of power history. Because there are a little of available U-TRU-Zr or TRU-Zr characteristics, the material data of U-Pu-Zr or Pu-Zr are used for those of U-TRU-Zr or TRU-Zr. This report is mainly intended as a user's manual for the DIMAC code. The general description on this code, the description on input parameter, the description on each subroutine, the sample problem and the sample input and partial output are written in this repo0008.

  11. Age Differences in Future Orientation and Delay Discounting

    Science.gov (United States)

    Steinberg, Laurence; Graham, Sandra; O'Brien, Lia; Woolard, Jennifer; Cauffman, Elizabeth; Banich, Marie

    2009-01-01

    Age differences in future orientation are examined in a sample of 935 individuals between 10 and 30 years using a delay discounting task as well as a new self-report measure. Younger adolescents consistently demonstrate a weaker orientation to the future than do individuals aged 16 and older, as reflected in their greater willingness to accept a…

  12. Air sampling in the workplace to meet the new part 20 requirements

    International Nuclear Information System (INIS)

    McGuire, S.; Hickey, E.E.; Knox, W.

    1991-01-01

    The US Nuclear Regulatory Commission is developing a Regulatory Guide on air sampling in the workplace to meet the requirements of the revised Part 20. The guide will be accompanied by a technical manual describing and giving examples of how to meet the recommendations in the guide. Draft versions of the guide and manual are scheduled to be published for public comment this year. A final guide and manual, revised to consider the public comments, are scheduled to be published in 1992. This talk will summarize some of the more important features of the guide and manual. In particular, the talk will discuss how to demonstrate that samples taken to estimate worker intakes are representative of the air inhaled by workers and what measurements are necessary if a licensee wants to adjust derived air concentrations to account for particle size

  13. Marketing Research. Instructor's Manual.

    Science.gov (United States)

    Small Business Administration, Washington, DC.

    Prepared for the Administrative Management Course Program, this instructor's manual was developed to serve small-business management needs. The sections of the manual are as follows: (1) Lesson Plan--an outline of material covered, which may be used as a teaching guide, presented in two columns: the presentation, and a step-by-step indication of…

  14. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  15. 25 CFR 175.5 - Operations manual.

    Science.gov (United States)

    2010-04-01

    ... Provisions § 175.5 Operations manual. (a) The Area Director shall establish an operations manual for the... Director shall amend the operations manual as needed. (b) The public shall be notified by the Area Director... shall be published in local newspaper(s) of general circulation, posted at the utility office(s), and...

  16. AFM-CMM integrated instrument user manual

    DEFF Research Database (Denmark)

    Marinello, Francesco; Bariani, Paolo

    This manual gives general important guidelines for a proper use of the integrated AFM-CMM instrument. More information can be collected reading: • N. Kofod Ph.D thesis [1]; • P. Bariani Ph.D thesis [2]; • Dualscope DME 95-200 operation manuals [3]; • SPIP help [4] • Stitching software user manual...

  17. Sampling Strategies and Processing of Biobank Tissue Samples from Porcine Biomedical Models.

    Science.gov (United States)

    Blutke, Andreas; Wanke, Rüdiger

    2018-03-06

    In translational medical research, porcine models have steadily become more popular. Considering the high value of individual animals, particularly of genetically modified pig models, and the often-limited number of available animals of these models, establishment of (biobank) collections of adequately processed tissue samples suited for a broad spectrum of subsequent analyses methods, including analyses not specified at the time point of sampling, represent meaningful approaches to take full advantage of the translational value of the model. With respect to the peculiarities of porcine anatomy, comprehensive guidelines have recently been established for standardized generation of representative, high-quality samples from different porcine organs and tissues. These guidelines are essential prerequisites for the reproducibility of results and their comparability between different studies and investigators. The recording of basic data, such as organ weights and volumes, the determination of the sampling locations and of the numbers of tissue samples to be generated, as well as their orientation, size, processing and trimming directions, are relevant factors determining the generalizability and usability of the specimen for molecular, qualitative, and quantitative morphological analyses. Here, an illustrative, practical, step-by-step demonstration of the most important techniques for generation of representative, multi-purpose biobank specimen from porcine tissues is presented. The methods described here include determination of organ/tissue volumes and densities, the application of a volume-weighted systematic random sampling procedure for parenchymal organs by point-counting, determination of the extent of tissue shrinkage related to histological embedding of samples, and generation of randomly oriented samples for quantitative stereological analyses, such as isotropic uniform random (IUR) sections generated by the "Orientator" and "Isector" methods, and vertical

  18. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-07-25

    The purpose of the Regulations and Procedures Manual (RPM) is to provide LBNL personnel with a reference to University and Lawrence Berkeley National Laboratory (LBNL or Laboratory) policies and regulations by outlining normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory organizations. Much of the information in this manual has been condensed from detail provided in LBNL procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. RPM sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the LBNL organization responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which organization is responsible for a policy, please contact Requirements Manager Lydia Young or the RPM Editor.

  19. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2010-09-30

    The purpose of the Regulations and Procedures Manual (RPM) is to provide Laboratory personnel with a reference to University and Lawrence Berkeley National Laboratory policies and regulations by outlining the normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory departments. Much of the information in this manual has been condensed from detail provided in Laboratory procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. The sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the department responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which department should be called, please contact the Associate Laboratory Director of Operations.

  20. Manual for subject analysis

    International Nuclear Information System (INIS)

    2002-01-01

    This document is one in a series of publications known as the ETDE/INIS Joint Reference Series and also constitutes a part of the ETDE Procedures Manual. It presents the rules, guidelines and procedures to be adopted by centers submitting input to the International Nuclear Information System (INIS) or the Energy Technology Data Exchange (ETDE). It is a manual for the subject analysis part of input preparation, meaning the selection, subject classification, abstracting and subject indexing of relevant publications, and is to be used in conjunction with the Thesauruses, Subject Categories documents and the documents providing guidelines for the preparation of abstracts. The concept and structure of the new manual are intended to describe in a logical and efficient sequence all the steps comprising the subject analysis of documents to be reported to INIS or ETDE. The manual includes new chapters on preparatory analysis, subject classification, abstracting and subject indexing, as well as rules, guidelines, procedures, examples and a special chapter on guidelines and examples for subject analysis in particular subject fields. (g.t.; a.n.)

  1. High-level neutron coincidence counter (HLNCC): users' manual

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1979-06-01

    This manual describes the portable High-Level Neutron Coincidence Counter (HLNCC) developed at the Los Alamos Scientific Laboratory (LASL) for the assay of plutonium, particularly by inspectors of the International Atomic Energy Agency (IAEA). The counter is designed for the measurement of the effective 240 Pu mass in plutonium samples which may have a high plutonium content. The following topics are discussed: principle of operation, description of the system, operating procedures, and applications

  2. An Instrumented Glove to Assess Manual Dexterity in Simulation-Based Neurosurgical Education

    Directory of Open Access Journals (Sweden)

    Juan Diego Lemos

    2017-04-01

    Full Text Available The traditional neurosurgical apprenticeship scheme includes the assessment of trainee’s manual skills carried out by experienced surgeons. However, the introduction of surgical simulation technology presents a new paradigm where residents can refine surgical techniques on a simulator before putting them into practice in real patients. Unfortunately, in this new scheme, an experienced surgeon will not always be available to evaluate trainee’s performance. For this reason, it is necessary to develop automatic mechanisms to estimate metrics for assessing manual dexterity in a quantitative way. Authors have proposed some hardware-software approaches to evaluate manual dexterity on surgical simulators. This paper presents IGlove, a wearable device that uses inertial sensors embedded on an elastic glove to capture hand movements. Metrics to assess manual dexterity are estimated from sensors signals using data processing and information analysis algorithms. It has been designed to be used with a neurosurgical simulator called Daubara NS Trainer, but can be easily adapted to another benchtop- and manikin-based medical simulators. The system was tested with a sample of 14 volunteers who performed a test that was designed to simultaneously evaluate their fine motor skills and the IGlove’s functionalities. Metrics obtained by each of the participants are presented as results in this work; it is also shown how these metrics are used to automatically evaluate the level of manual dexterity of each volunteer.

  3. Operating manual for the emission spectrometer NOI-6e for laboratory use

    International Nuclear Information System (INIS)

    Albornoz G, M.P.

    1993-08-01

    This manual describes graphically and specifically how to operate the Emission Spectrometer NOI-6e. Detailed instructions are given for everything form turning on the equipment, quality control of several parameters, calibration, sample analysis; measurements and obtaining final results form the microprocessors. (author)

  4. Waste Characterization Data Manual for the inactive liquid low-level waste tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1993-06-01

    This Waste Characterization Data Manual contains the results of an analysis of the contents of liquid low-level waste (LLLW) tanks that have been removed from service in accordance with the requirements of the Oak Ridge National Laboratory (ORNL) Federal Facility Agreement (FFA), Section IX.G.1. Section IX.G.1 of the FFA requires waste characterizations be conducted and provided to EPA and TDEC for all LLLW tanks that are removed from service. These waste characterizations shall include the results of sampling and analysis of the tank contents, including wastes, liquids, and sludges. This manual was first issued as ORNL/ER-80 in June 1992. The waste characterization data were extracted from ORNL reports that described tank sampling and analysis conducted in 1988 for 32 out-of-service tanks. This revision of the manual contains waste characterization data for 54 tanks, including the 32 tanks from the 1988 sampling campaign (Sects. 2.1 through 2.32) and the 22 additional tanks from a subsequent sampling campaign in 1992 and 1993 (Sects. 2.33 through 2.54). Data are presented from analyses of volatile organic compounds, semivolatile organic compounds, polychlorinated biphenyls (PCBs), pesticides, radiochemical compounds, and inorganic compounds. As additional data resulting from analyses of out-of-service tank samples become available, they will be added to this manual

  5. Strategic Orientation of SMEs: Empirical Research

    Directory of Open Access Journals (Sweden)

    Jelena Minović

    2016-04-01

    Full Text Available The main objective of the paper is to identify the sources of competitive advantage of small and medium-sized enterprises in Serbia. Gaining a competitive advantage is the key priority of market-oriented enterprises regardless of their size and sector. Since business environment in Serbia is not stimulating enough for enterprises’ growth and development, the paper highlights the role of strategic orientation in business promotion and development. In order to identify the sources of competitive advantage, the empirical research is conducted by using the survey method. The research sample is created by using a selective approach, namely, the sample includes enterprises with more than ten employees, and enterprises identified to have the potential for growth and development. The research results indicate that small and medium-sized enterprises in Serbia are generally focused on costs as a source of competitive advantage, i.e., they gain competitive advantage in a selected market segment by offering low price and average quality products/services. In addition, the results of the research point out that the Serbian small and medium-sized enterprises are innovation-oriented. Organizations qualifying as middle-sized enterprises are predominantly focused on process innovations, while small businesses are primarily oriented towards product innovations. One of the limitations of the research refers to the small presence of the research sample within the category of middle-sized enterprises. The smaller sample presence than it was previously planned is mostly due to the lack of managers’ willingness to participate in the research, as well as to the fact that these enterprises account for the smaller share in the total number of enterprises in the small-and medium-sized enterprises’ sector. Taking into account that the sector of small and medium-sized enterprises generates around 30% of the country’s GDP, we consider the research results to be

  6. Reconceptualising manual therapy skills in contemporary practice.

    Science.gov (United States)

    Rabey, Martin; Hall, Toby; Hebron, Clair; Palsson, Thorvaldur Skuli; Christensen, Steffan Wittrup; Moloney, Niamh

    2017-06-01

    With conflicting evidence regarding the effectiveness of manual therapy calls have arisen within some quarters of the physiotherapy profession challenging the continued use of manual skills for assessment and treatment. A reconceptualisation of the importance of manual examination findings is put forward, based upon a contemporary understanding of pain science, rather than considering these skills only in terms of how they should "guide" manual therapy interventions. The place for manual examination findings within complex, multidimensional presentations is considered using vignettes describing the presentations of five people with low back pain. As part of multidimensional, individualised management, the balance of evidence relating to the effectiveness, mechanisms of action and rationale for manual skills is discussed. It is concluded that if manual examination and therapeutic skills are used in a manner consistent with a contemporary understanding of pain science, multidimensional patient profiles and a person-centred approach, their selective and judicious use still has an important role. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Goal orientations predict academic performance beyond intelligence and personality

    NARCIS (Netherlands)

    Steinmayr, R.; Bipp, T.; Spinath, B.

    2011-01-01

    Goal orientations are thought to be an important predictor of scholastic achievement. The present paper investigated the joint influence of goal orientations, intelligence, and personality on school performance in a sample of N = 520 11th and 12th graders (303 female; mean age M = 16.94 years).

  8. Does Promotion Orientation Help Explain Why Future-Orientated People Exercise and Eat Healthy?

    Science.gov (United States)

    Milfont, Taciano L; Vilar, Roosevelt; Araujo, Rafaella C R; Stanley, Robert

    2017-01-01

    A study with United States undergraduate students showed individuals high in concern with future consequences engage in exercise and healthy eating because they adopt a promotion orientation, which represents the extent to which individuals are inclined to pursue positive gains. The present article reports a cross-cultural replication of the mediation findings with undergraduate samples from Brazil and New Zealand. Promotion orientation mediated the association between concern with future consequences and exercise attitudes in both countries, but the associations for healthy eating were not replicated-which could be explained by distinct obesity prevalence and eating habits in these socio-cultural contexts. We discuss theoretical and practical implications of the findings for promoting health behavior.

  9. Does Promotion Orientation Help Explain Why Future-Orientated People Exercise and Eat Healthy?

    Directory of Open Access Journals (Sweden)

    Taciano L. Milfont

    2017-07-01

    Full Text Available A study with United States undergraduate students showed individuals high in concern with future consequences engage in exercise and healthy eating because they adopt a promotion orientation, which represents the extent to which individuals are inclined to pursue positive gains. The present article reports a cross-cultural replication of the mediation findings with undergraduate samples from Brazil and New Zealand. Promotion orientation mediated the association between concern with future consequences and exercise attitudes in both countries, but the associations for healthy eating were not replicated—which could be explained by distinct obesity prevalence and eating habits in these socio-cultural contexts. We discuss theoretical and practical implications of the findings for promoting health behavior.

  10. Screening for Sexual Orientation in Psychiatric Emergency Departments

    Directory of Open Access Journals (Sweden)

    Currier, Glenn W.

    2015-01-01

    Full Text Available Introduction: Our goal was to explore whether emergency department (ED patients would disclose their sexual orientation in a research evaluation and to examine demographic and clinical characteristics of patients by self-identified sexual orientation. Methods: Participants (n=177 presented for psychiatric treatment at three urban EDs in New York City, Rochester, NY, and Philadelphia, PA. Participants were interviewed in the context of a larger study of a standardized suicide risk assessment. We assessed participants’ willingness to answer questions regarding sexual orientation along three dimensions: a self-description of sexual orientation, a self-description of sexual attraction, and the gender of any prior sexual partners. Results: No participants (0/177 refused to respond to the categorical question about sexual orientation, 168/177 (94.9% agreed to provide information about prior sexual partners, and 100/109 (91.7% provided information about current sexual attraction toward either gender. Of all 177 participants, 154 (87.0% self-identified as heterosexual, 11 (6.2% as bisexual, 10 (5.6% as gay or lesbian, and 2 (1.1% indicated they were not sure. As compared with heterosexual patients, lesbian, gay and bisexual (LGB patients were significantly younger and more likely to be non-white, but did not differ significantly in terms of education, income, employment, or religious affiliation or participation. Further, LGB participants did not differ from self-identified heterosexual participants for lifetime suicide attempt rate or lifetime history of any mood, substance-related, psychotic spectrum, or other Diagnostic and Statistical Manual of Mental Disorders, 4th edition (DSM-IV Axis I disorder. Of self-identified heterosexual participants 5.6% (5/89 reported sexual attraction as other than ‘only opposite sex,’ and 10.3% (15/142 of sexually active ‘heterosexual’ participants reported previous same-gender sexual partners. Conclusion

  11. Waste characterization data manual for the inactive liquid low-level waste tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    This Waste Characterization Data Manual contains the results of an analysis of the contents of liquid low-level waste (LLLW) tanks that have been removed from service in accordance with the requirements of the Oak Ridge Reservation (ORR) Federal Facility Agreement (FFA), Sect. IX.G.1. This manual contains the results of sampling activities that were conducted at the Oak Ridge National Laboratory in 1988. Thirty-three tanks were sampled and analyzed at that time. Sampling of the remaining inactive tanks is currently underway, and data from these tanks will be added to this manual as they become available. Data are presented from analysis of volatile organic compounds, semivolatile organic compounds, polychlorinated biphenyls, radiochemical compounds, and inorganic compounds.

  12. TRUBA User Manual

    International Nuclear Information System (INIS)

    Tereshchenko, M. A.; Castejon, F.; Cappa, A.

    2008-01-01

    The TRUBA (pipeline in Russian) code is a computational tool for studying the propagation of Gaussian-shaped microwave beams in a prescribed equilibrium plasma. This manual covers the basic material handed to use the implementation of TRUBA (version 3,4) interfaced with the numerical library of the TJ-II stellarator. The manual provides a concise theoretical background of the problem, specifications for setting up the input files and interpreting the output of the code, and some information useful in modifying TRUBA. (Author) 13 refs

  13. TRUBA User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Tereshchenko, M. A.; Castejon, F.; Cappa, A.

    2008-04-25

    The TRUBA (pipeline in Russian) code is a computational tool for studying the propagation of Gaussian-shaped microwave beams in a prescribed equilibrium plasma. This manual covers the basic material handed to use the implementation of TRUBA (version 3,4) interfaced with the numerical library of the TJ-II stellarator. The manual provides a concise theoretical background of the problem, specifications for setting up the input files and interpreting the output of the code, and some information useful in modifying TRUBA. (Author) 13 refs.

  14. Developing a Pupil Transportation Manual.

    Science.gov (United States)

    Douglas, Dave

    1987-01-01

    District-level pupil transportation manuals that contain clear, concise information about objectives, policies, and regulations are a must. These manuals should also specify procedures concerning evaluation processes, personnel recruitment and selection, and the driver training program. (MLH)

  15. Personal Level Customer Orientation in Russian Direct Selling Market

    OpenAIRE

    Alexander Rozhkov

    2014-01-01

    In the modern world the importance of customer orientation cannot be underestimated. It hugely impacts the overall business performance, as well as separate areas of business-customer interaction. In this paper, we examine the role of personal level relations and customer orientation in the direct selling industry in the Russian market. Based on a sample of over 6000 participants in 74 regions of Russia, we develop a model revealing the factors that define the level of customer orientation in...

  16. Incorporating prior knowledge into beam orientation optimization in IMRT

    International Nuclear Information System (INIS)

    Pugachev, Andrei M.S.; Lei Xing

    2002-01-01

    Purpose: Selection of beam configuration in currently available intensity-modulated radiotherapy (IMRT) treatment planning systems is still based on trial-and-error search. Computer beam orientation optimization has the potential to improve the situation, but its practical implementation is hindered by the excessive computing time associated with the calculation. The purpose of this work is to provide an effective means to speed up the beam orientation optimization by incorporating a priori geometric and dosimetric knowledge of the system and to demonstrate the utility of the new algorithm for beam placement in IMRT. Methods and Materials: Beam orientation optimization was performed in two steps. First, the quality of each possible beam orientation was evaluated using beam's-eye-view dosimetrics (BEVD) developed in our previous study. A simulated annealing algorithm was then employed to search for the optimal set of beam orientations, taking into account the BEVD scores of different incident beam directions. During the calculation, sampling of gantry angles was weighted according to the BEVD score computed before the optimization. A beam direction with a higher BEVD score had a higher probability of being included in the trial configuration, and vice versa. The inclusion of the BEVD weighting in the stochastic beam angle sampling process made it possible to avoid spending valuable computing time unnecessarily at 'bad' beam angles. An iterative inverse treatment planning algorithm was used for beam intensity profile optimization during the optimization process. The BEVD-guided beam orientation optimization was applied to an IMRT treatment of paraspinal tumor. The advantage of the new optimization algorithm was demonstrated by comparing the calculation with the conventional scheme without the BEVD weighting in the beam sampling. Results: The BEVD tool provided useful guidance for the selection of the potentially good directions for the beams to incident and was used

  17. Missouri Highway Safety Manual Recalibration

    Science.gov (United States)

    2018-05-01

    The Highway Safety Manual (HSM) is a national manual for analyzing the highway safety of various facilities, including rural roads, urban arterials, freeways, and intersections. The HSM was first published in 2010, and a 2014 supplement addressed fre...

  18. Determination of three-dimensional stress orientations in the Wenchuan earthquake Fault Scientific Drilling (WFSD) hole-1: A preliminary result by anelastic strain recovery measurements of core samples

    Science.gov (United States)

    Cui, J.; Lin, W.; Wang, L.; Tang, Z.; Sun, D.; Gao, L.; Wang, W.

    2010-12-01

    A great and destructive earthquake (Ms 8.0; Mw 7.9), Wunchuan earthquake struck on the Longmen Shan foreland trust zone in Sichuan province, China on 12 May 2008 (Xu et al., 2008; Episodes, Vol.31, pp.291-301). As a rapid response scientific drilling project, Wenchuan earthquake Fault Scientific Drilling (WFSD) started on 6 November 2008 shorter than a half of year from the date of earthquake main shock. The first pilot borehole (hole-1) has been drilled to the target depth (measured depth 1201 m MD, vertical depth 1179 m) at Hongkou, Dujianyan, Sichuan and passed through the main fault of the earthquake around 589 m MD. We are trying to determine three dimensional in-situ stress states in the WFSD boreholes by a core-based method, anelastic strain recovery (ASR) method (Lin et al., 2006; Tectonophysics, Vol4.26, pp.221-238). This method has been applied in several scientific drilling projects (TCDP: Lin et al., 2007; TAO, Vol.18, pp.379-393; NanTtoSEIZE: Byrne et al., 2009; GRL, Vol.36, L23310). These applications confirm the validity of using the ASR technique in determining in situ stresses by using drilled cores. We collected total 15 core samples in a depth range from 340 m MD to 1180 m MD, approximately for ASR measurements. Anelastic normal strains, measured every ten minutes in nine directions, including six independent directions, were used to calculate the anelastic strain tensors. The data of the ASR tests conducted at hole-1 is still undergoing analysis. As a tentative perspective, more than 10 core samples showed coherent strain recovery over one - two weeks. However, 2 or 3 core samples cannot be re-orientated to the global system. It means that we cannot rink the stress orientation determined by the core samples to geological structure. Unfortunately, a few core samples showed irregular strain recovery and were not analyzed further. The preliminary results of ASR tests at hole-1 show the stress orientations and stress regime changes a lot with the

  19. US Department of Energy Radiological Control Manual

    International Nuclear Information System (INIS)

    1992-06-01

    This manual establishes practices for the conduct of radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. (VC)

  20. Long-term monitoring of soil gas fluxes with closed chambers using automated and manual systems

    Energy Technology Data Exchange (ETDEWEB)

    Scott, A.; Crichton, I.; Ball, B.C.

    1999-10-01

    The authors describe two gas sample collection techniques, each of which is used in conjunction with custom made automated or manually operated closed chambers. The automated system allows automatic collection of gas samples for simultaneous analysis of multiple trace gas efflux from soils, permitting long-term monitoring. Since the manual system is cheaper to produce, it can be replicated more than the automated and used to estimate spatial variability of soil fluxes. The automated chamber covers a soil area of 0.5 m{sup 2} and has a motor driven lid that remains operational throughout a range of weather conditions. Both systems use gas-tight containers of robust metal construction, which give good sample retention, thereby allowing long-term storage and convenience of transport from remote locations. The containers in the automated system are filled by pumping gas from the closed chamber via a multiway rotary valve. Stored samples from both systems are analyzed simultaneously for N{sub 2}O and CO{sub 2} using automated injection into laboratory-based gas chromatographs. The use of both collection systems is illustrated by results from a field experiment on sewage sludge disposal to land where N{sub 2}O fluxes were high. The automated gas sampling system permitted quantification of the marked temporal variability of concurrent N{sub 2}O and CO{sub 2} fluxes and allowed improved estimation of cumulative fluxes. The automated measurement approach yielded higher estimates of cumulative flux because integration of manual point-in-time observations missed a number of transient high-flux events.

  1. Surgical Implications of Asymmetric Distribution of Dermal Collagen and Elastic Fibres in Two Orientations of Skin Samples from Extremities

    Directory of Open Access Journals (Sweden)

    Naveen Kumar

    2014-01-01

    Full Text Available Background. Clinically, scar related complications are observed to be dissimilar in different regions of the body. Unequal distribution of dermal collagen and elastic fibres in different orientations could be one of the multifocal causes of scar related complications, for which this evaluating study has been taken up. Materials and Method. 300 skin samples collected in horizontal and vertical orientations were studied histomorphometrically. This study involved image analysis of specially stained histological section using tissue-quant software. The outcome result was termed as quantitative fraction. From the result, various ratio values were also calculated for the ratio analysis. Results. The differences in the quantitative fraction of dermal elastic content between 2 directions were statistically significant at joint areas (shoulder joint, wrist, and ankle (P<0.001 but for collagen, significant difference was observed at shoulder joint and wrist only. Dermis of the forearm and thigh did not show any differences in their collagen content, but for elastic, thigh did show a significant difference while forearm had no change between 2 directions. Conclusion. Analysis of unequal content of dermal element in two directions under the perspective of wound healing consequences is subjective depending upon the anatomical position and functional status of the areas.

  2. Automatic sample changer control software for automation of neutron activation analysis process in Malaysian Nuclear Agency

    Science.gov (United States)

    Yussup, N.; Ibrahim, M. M.; Rahman, N. A. A.; Mokhtar, M.; Salim, N. A. A.; Soh@Shaari, S. C.; Azman, A.; Lombigit, L.; Azman, A.; Omar, S. A.

    2018-01-01

    Most of the procedures in neutron activation analysis (NAA) process that has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s were performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient especially for sample counting and measurement process. The sample needs to be changed and the measurement software needs to be setup for every one hour counting time. Both of these procedures are performed manually for every sample. Hence, an automatic sample changer system (ASC) that consists of hardware and software is developed to automate sample counting process for up to 30 samples consecutively. This paper describes the ASC control software for NAA process which is designed and developed to control the ASC hardware and call GammaVision software for sample measurement. The software is developed by using National Instrument LabVIEW development package.

  3. Comparison of manual and automated cell counts in EDTA preserved synovial fluids. Storage has little influence on the results.

    Science.gov (United States)

    Salinas, M; Rosas, J; Iborra, J; Manero, H; Pascual, E

    1997-10-01

    To determine the precision and agreement of synovial fluid (SF) cell counts done manually and with automated counters, and to determine the degree of variability of the counts in SF samples, kept in the tubes used for routine white blood cell (WBC) counts--which use liquid EDTA as anticoagulant--at 24 and 48 hours at 4 degrees C, and at room temperature. To determine precision, cell counts were repeated 10 times--both manually and by an automated counter--in a SF sample of low, medium, and high cellularity. The variances were calculated to determine the interobserver variation in two manual (M1,M2) and two automated cell counts (C1,C2). The agreement between a manual (M1) and automated counter (C1) results, was analysed by the Bland and Altman method and the difference against the mean of the two methods was plotted. Then, the mean difference between the two methods was estimated and the standard deviation of the difference. To determine the effects of storage, SF samples were kept in a refrigerator at 4 degrees C, and at room temperature; cell counts were done manually (M1) and automatically (C1) at 24 and 48 hours and the changes analysed by the Bland and Altman method. The variances were compared using an F test. (1) Precision. With the manual technique, the coefficients of variation were 27.9%, 14%, and 10.7% when used for counting the SF with low (270), medium (6200), and high cellularities (25,000). With the automated technique the coefficients of variation were 20%, 3.4%, and 2.9% in the same SF samples. In the fluids of medium and high cellularity, the variances of the automated cell counts were significatively lower (F test, p automated counter. (4) Influence of storage. The coulter counts of SF samples preserved at 4 degrees C showed less variance (F test, p Automated cell count of the SF offers advantages: it gives higher precision and consumes less time. The stability of the samples preserved in the EDTA tubes used for routine WBC counts is of

  4. Self-Esteem and Future Orientation Predict Adolescents' Risk Engagement

    Science.gov (United States)

    Jackman, Danielle M.; MacPhee, David

    2017-01-01

    This study's purpose was to examine the relations among future orientation, self-esteem, and later adolescent risk behaviors, and to compare two mediational models involving self-esteem versus future orientation as mediators. An ethnically diverse sample of 12- to 14-year-olds (N = 862, 54% female, 53% ethnic minority) was assessed longitudinally.…

  5. Reconceptualising manual therapy skills in contemporary practice

    DEFF Research Database (Denmark)

    Rabey, Martin; Hall, Toby; Hebron, Clair

    2017-01-01

    With conflicting evidence regarding the effectiveness of manual therapy calls have arisen within some quarters of the physiotherapy profession challenging the continued use of manual skills for assessment and treatment. A reconceptualisation of the importance of manual examination findings is put...

  6. New highway accident location manual for Missouri.

    Science.gov (United States)

    2013-12-01

    The Missouri HAL manual is used to identify, analyze, and correct high crash locations, and has not been updated since : 1999. This new edition brings the manual up to date, while incorporating the methodology of the national Highway Safety : Manual ...

  7. Phantom Study Investigating the Accuracy of Manual and Automatic Image Fusion with the GE Logiq E9: Implications for use in Percutaneous Liver Interventions

    Energy Technology Data Exchange (ETDEWEB)

    Burgmans, Mark Christiaan, E-mail: m.c.burgmans@lumc.nl; Harder, J. Michiel den, E-mail: chiel.den.harder@gmail.com; Meershoek, Philippa, E-mail: P.Meershoek@lumc.nl [Leiden University Medical Centre, Department of Radiology (Netherlands); Berg, Nynke S. van den, E-mail: N.S.van-den-Berg@lumc.nl [Leiden University Medical Center, Interventional and Molecular Imaging Laboratory, Department of Radiology (Netherlands); Chan, Shaun Xavier Ju Min, E-mail: shaun.xavier.chan@singhealth.com.sg [Singapore General Hospital, Department of Interventional Radiology (Singapore); Leeuwen, Fijs W. B. van, E-mail: F.W.B.van-Leeuwen@lumc.nl [Leiden University Medical Center, Interventional and Molecular Imaging Laboratory, Department of Radiology (Netherlands); Erkel, Arian R. van, E-mail: a.r.van-erkel@lumc.nl [Leiden University Medical Centre, Department of Radiology (Netherlands)

    2017-06-15

    PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.

  8. Estimating energy impacts of residential and commercial building development. A manual for the Pacific Northwest and Alaska

    Energy Technology Data Exchange (ETDEWEB)

    1979-02-22

    This energy-impact manual presents information on energy implications of new building design and operation, providing a reasonably accurate means of assessing the total energy impact of new construction in the commercial and residential sectors. While developed specifically for the states of Alaska, Idaho, Oregon, and Washington, much of the data used are national averages; the procedures described are applicable to other regions of the nation, with appropriate adjustments for climatic differences. The manual is organized into three parts, each covering one aspect of the energy impacts of building development. Part I addresses the energy impact of erecting the building(s). This includes the energy cost of grading and excavating and other site preparation. It also takes into account the energy embodied in the fabrication of materials used in building construction, as well as the energy cost of transporting materials to the site and assembling them. Part II focuses on the end use of energy during normal building operation, i.e., the energy consumed for space heating, cooling, lighting, water heating, etc. A simplified calculation sequence is provided which allows the user to estimate the consumption of most combinations of building orientation, characteristics, and operating conditions. Part III examines the relationship of land use to energy consumption, principally the transportation energy impact of various land-development patterns, the embodied energy impacts of infrastructure requirements, and the impacts of various orientation and siting schemes. (MCW)

  9. Gender role, sexual orientation and suicide risk.

    Science.gov (United States)

    Fitzpatrick, Kathleen Kara; Euton, Stephanie J; Jones, Jamie N; Schmidt, Norman B

    2005-07-01

    There has been interest in the relationship between homosexuality, gender role and suicide risk. Though homosexuals are more likely to identify as cross-gender, research has not simultaneously examined sexual orientation and gender role in assessing suicide risk. In the current study, the unique and interactive effects of sexual orientation and gender role were assessed in regard to suicidal ideation, related psychopathology and measures of coping. 77 participants were recruited from an undergraduate psychology subject pool (n=47) or from gay, lesbian and transgender student organizations (n=30) and assessed on measures of gender role, homosexuality, and psychopathology. Consistent with expectations, cross-gender role (i.e., personality traits associated with the opposite sex) is a unique predictor of suicidal symptoms. Moreover, gender role accounted for more of the overall variance in suicidal symptoms, positive problem orientation, peer acceptance and support, than sexual orientation. After accounting for gender role, sexual orientation contributed little to the variance in suicidal symptoms, associated pathology and problem-solving deficits. There was no support for gender role by sexual orientation interaction effects. The cross-sectional nature of the data limits statements regarding causality. Cross-gendered individuals, regardless of sexual orientation, appear to have higher risk for suicidal symptoms. Researchers and clinicians should assess gender role in evaluations of youth samples.

  10. BLOCKAGE 2.5 user's manual

    International Nuclear Information System (INIS)

    Rao, D.V.; Brideau, J.; Shaffer, C.; Souto, F.; Bernahl, W.

    1996-12-01

    The BLOCKAGE 2.5 code described in this User's Manual was developed by the US Nuclear Regulatory Commission (NRC) as a tool to evaluate licensee compliance with NRC Bulletin 96-03, ''Potential Plugging of Emergency Core Cooling Suction Strainers by Debris in Boiling Water Reactors.'' As such, BLOCKAGE 2.5 provides a generalized framework into which a user can input plant-specific and insulation-specific data for performing analyses in accordance with Regulatory Guide 1.82, Rev. 2. This user's manual describes the capabilities of BLOCKAGE 2.5 along with a description of the graphics user's interface provided for data entry. Each input/output dialog is described in detail along with special considerations related to developing and executing BLOCKAGE. Also, several sample problems are provided such that user can easily modify them to suit a particular plant of interest. The models used in BLOCKAGE 2.5 and their validation are presented in the accompanying NUREG/CR-6371. The BLOCKAGE models were designed to be parametric in nature, allowing the user flexibility to examine the impact of several modeling assumptions and to conduct sensitivity analyses. As a result, BLOCKAGE 2.5 results are known to be very sensitive to the user provided input. It is therefore strongly recommended that users become thoroughly familiar with BLOCKAGE models and their limitations as described in NUREG/CR-6224

  11. Entrepreneurial orientation, market orientation, and competitive environment

    DEFF Research Database (Denmark)

    Sørensen, Hans Eibe; Cadogan, John W.

    This study sheds light on the role that the competitive environment plays in determining how elements of market orientation and elements of entrepreneurial orientation interact to influence business success. We develop a model in which we postulate that market orientation, entrepreneurial...... orientation, and competitive environment shape business performance via a three-way interaction. We test the model using primary data from the CEOs of 270 CEO of manufacturing firms, together with secondary data on these firms' profit performance. An assessment of the results indicates that customer...... orientation moderates the positive relationships between the competitiveness element of entrepreneurial orientation and market share and return on assets (ROA): the positive relationships between competitiveness and market share and competitiveness and ROA become stronger the greater the firms' customer...

  12. Aircraft operations management manual

    Science.gov (United States)

    1992-01-01

    The NASA aircraft operations program is a multifaceted, highly diverse entity that directly supports the agency mission in aeronautical research and development, space science and applications, space flight, astronaut readiness training, and related activities through research and development, program support, and mission management aircraft operations flights. Users of the program are interagency, inter-government, international, and the business community. This manual provides guidelines to establish policy for the management of NASA aircraft resources, aircraft operations, and related matters. This policy is an integral part of and must be followed when establishing field installation policy and procedures covering the management of NASA aircraft operations. Each operating location will develop appropriate local procedures that conform with the requirements of this handbook. This manual should be used in conjunction with other governing instructions, handbooks, and manuals.

  13. Impacts of fiber orientation and milling on observed crystallinity in jack pine

    Science.gov (United States)

    Umesh P. Agarwal; Sally A. Ralph; Richard S. Reiner; Roderquita K. Moore; Carlos Baez

    2014-01-01

    Influences of fiber orientation and milling on wood cellulose crystallinity were studied using jack pine wood. The fiber orientation effects were measured by sampling rectangular wood blocks in radial, tangential, and cross-sectional orientations. The influence of milling was studied by analyzing the unsieved and sieved milled wood fractions (all

  14. Age-Related Physical Changes Interfere With Judgments of Male Sexual Orientation From Faces.

    Science.gov (United States)

    Tskhay, Konstantin O; Krendl, Anne C; Rule, Nicholas O

    2016-09-01

    Although studies have shown that sexual orientation can be judged from faces, this research has not considered how age-related differences in perceivers or targets affect such judgments. In the current work, we evaluated whether accuracy differed among young adults (YA) and older adults (OA) for young and old men's faces by recruiting a sample of YA and OA in the lab, a community sample of sexual minority men, and a sample of online participants. We found that OA and YA judged sexual orientation with similar accuracy. Perceptions of gender atypicality mediated the difference in judging older and younger targets' sexual orientation. Although participants used positive affect to correctly discern sexual orientation regardless of target age, perceptions of masculinity were valid only for judgments of YA. © 2016 by the Society for Personality and Social Psychology, Inc.

  15. CEOs’ Strategic Orientations in the Most Successful Slovenian Companies

    Directory of Open Access Journals (Sweden)

    Dario Berginc

    2014-09-01

    Full Text Available This article presents the concept of a CEO’s strategic orientation as one of the most important elements of the research into a company’s successfulness. Managerial perception is in many ways more important than environmental analysis, since CEOs determine their company’s future strategic orientations. A study of CEOs’ strategic orientations can provide better information regarding companies’ strategic orientations. We performed a qualitative study of CEOs from a sample of the most successful Slovenian ompanies. The research results indicate numerous commonalities between CEOs’ opinions and standpoints, as well as some differences in relation to the characteristics of the companies and industries in which they operate.

  16. ETAP user's manual

    International Nuclear Information System (INIS)

    Watanabe, Norio; Higuchi, Suminori.

    1990-11-01

    The event tree analysis technique has been used in Probabilistic Safety Assessment for LWRs to delineate various accident scenarios leading to core melt or containment failure and to evaluate their frequencies. This technique often requires manual preparation of event trees with iterative process and time-consuming work in data handling. For the purpose of reducing manual efforts in event tree analysis, we developed a new software package named ETAP (Event Tree Analysis Supporting Program) for event tree analysis. ETAP is an interactive PC-based program which has the ability to construct, update, document, and quantify event trees. Because of its fast running capability to quantify event trees, use of the EATP program can make it easy to perform the sensitivity studies on a variety of system/containment performance issues. This report provides a user's manual for ETAP, which describes the structure, installation, and use of EATP. This software runs on NEC/PC-9800 or compatible PCs that have a 640 KB memory and MS-DOS 2.11 or higher. (author)

  17. OASIS User Manual

    CERN Document Server

    Bojtar, L

    2009-01-01

    The OASIS system has been operational for years now. After a long development the project has reached a state where the number of features it provides exceeds largely what most of its users knows about. The author felt it was time to write a user manual explaining all the functionality of the viewer application. This document is a user manual, concentrating on the functionality of the viewer from the user’s point of view. There are already documents available on the project’s web site about the technical aspects at http://project-oasis.web.cern.ch/project-oasis/presentations.htm . There was an attempt to produce a tutorial on the viewer, but it didn’t get much further than the table of contents, that however is well thought. The structure of this user manual follows the same principle, the basic and most often used features are grouped together. Advanced or less often used features are described in a separate chapter. There is a second organizational principle, features belong to different levels: chann...

  18. Methane measurements manual; Handbok metanmaetningar

    Energy Technology Data Exchange (ETDEWEB)

    Holmgren, Magnus Andreas (SP Technical research institute of Sweden, Boraas (Sweden))

    2011-02-15

    Emissions to air in different parts of the system may arise in biogas plants, where there is biological treatment of organic matter by anaerobic degradation, and during upgrading of biogas to vehicle fuel. There are mainly four reasons why these emissions must be minimized. These are safety, greenhouse gas emissions, economy and smell. This manual gathers experience of several years of work with measurement of methane emissions from biogas and upgrading facilities. This work has been done mainly in the context of Swedish Waste Management's system of voluntary commitment. The purpose of this manual is to standardize methods and procedures when methane measurements are carried out so that the results are comparable between different providers. The main target group of the manual is measurement consultants performing such measurements. Calculation template in Excel is part of the manual, which further contributes to the measurements evaluated in a standardized way. The manual contains several examples which have been calculated in the accompanying Excel template. The handbook also contains a chapter mainly intended for facility staff, in which implementation of accurate leak detection is described, and where there are hints of a system of so-called intermediate inspections to detect leaks in time

  19. Age-related differences in regional brain volumes: A comparison of optimized voxel-based morphometry to manual volumetry

    Science.gov (United States)

    Kennedy, Kristen M.; Erickson, Kirk I.; Rodrigue, Karen M.; Voss, Michelle W.; Colcombe, Stan J.; Kramer, Arthur F.; Acker, James D.; Raz, Naftali

    2009-01-01

    Regional manual volumetry is the gold standard of in vivo neuroanatomy, but is labor-intensive, can be imperfectly reliable, and allows for measuring limited number of regions. Voxel-based morphometry (VBM) has perfect repeatability and assesses local structure across the whole brain. However, its anatomic validity is unclear, and with its increasing popularity, a systematic comparison of VBM to manual volumetry is necessary. The few existing comparison studies are limited by small samples, qualitative comparisons, and limited selection and modest reliability of manual measures. Our goal was to overcome those limitations by quantitatively comparing optimized VBM findings with highly reliable multiple regional measures in a large sample (N = 200) across a wide agespan (18–81). We report a complex pattern of similarities and differences. Peak values of VBM volume estimates (modulated density) produced stronger age differences and a different spatial distribution from manual measures. However, when we aggregated VBM-derived information across voxels contained in specific anatomically defined regions (masks), the patterns of age differences became more similar, although important discrepancies emerged. Notably, VBM revealed stronger age differences in the regions bordering CSF and white matter areas prone to leukoaraiosis, and VBM was more likely to report nonlinearities in age-volume relationships. In the white matter regions, manual measures showed stronger negative associations with age than the corresponding VBM-based masks. We conclude that VBM provides realistic estimates of age differences in the regional gray matter only when applied to anatomically defined regions, but overestimates effects when individual peaks are interpreted. It may be beneficial to use VBM as a first-pass strategy, followed by manual measurement of anatomically-defined regions. PMID:18276037

  20. The minimal manual: is less really more?

    NARCIS (Netherlands)

    Lazonder, Adrianus W.; van der Meij, Hans

    1993-01-01

    Carroll, Smith-Kerker, Ford and Mazur-Rimetz (The minimal manual, Human-Computer Interaction , 3, 123-153, 1987) have introduced the minimal manual as an alternative to standard self-instruction manuals. While their research indicates strong gains, only a few attempts have been made to validate

  1. Personal Level Customer Orientation in Russian Direct Selling Market

    Directory of Open Access Journals (Sweden)

    Alexander Rozhkov

    2014-06-01

    Full Text Available In the modern world the importance of customer orientation cannot be underestimated. It hugely impacts the overall business performance, as well as separate areas of business-customer interaction. In this paper, we examine the role of personal level relations and customer orientation in the direct selling industry in the Russian market. Based on a sample of over 6000 participants in 74 regions of Russia, we develop a model revealing the factors that define the level of customer orientation in personal level interactions.

  2. Manual on indoor air quality

    International Nuclear Information System (INIS)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues

  3. Manual on indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues.

  4. Electrodeposited copper oxide films: Effect of bath pH on grain orientation and orientation-dependent interfacial behavior

    International Nuclear Information System (INIS)

    Wang, L.C.; Tacconi, N.R. de; Chenthamarakshan, C.R.; Rajeshwar, K.; Tao, M.

    2007-01-01

    Copper (I) oxide (Cu 2 O) films were cathodically electrodeposited on Sn-doped indium oxide substrates. The influence of electrodeposition bath pH on grain orientation and crystallite shape was carefully re-examined using X-ray diffraction and scanning electron microscopy. In addition to the (100) and (111) preferred orientations identified in two previous sets of studies, as the bath pH was varied in the present study from ∼ 7.5 to ∼ 12, a third preferred orientation, (110), was identified in a narrow pH range, ∼ 9.4 to ∼ 9.9. A remarkable shift in the flat-band potential (spanning ∼ 500 mV) was measured in a non-aqueous electrolyte medium for the various Cu 2 O samples obtained from baths of varying pH

  5. Manual for reactor produced radioisotopes

    International Nuclear Information System (INIS)

    2003-01-01

    Radioisotopes find extensive applications in several fields including medicine, industry, agriculture and research. Radioisotope production to service different sectors of economic significance constitutes an important ongoing activity of many national nuclear programmes. Radioisotopes, formed by nuclear reactions on targets in a reactor or cyclotron, require further processing in almost all cases to obtain them in a form suitable for use. Specifications for final products and testing procedures for ensuring quality are also an essential part of a radioisotope production programme. The International Atomic Energy Agency (IAEA) has compiled and published such information before for the benefit of laboratories of Member States. The first compilation, entitled Manual of Radioisotope Production, was published in 1966 (Technical Reports Series No. 63). A more elaborate and comprehensive compilation, entitled Radioisotope Production and Quality Control, was published in 1971 (Technical Reports Series No. 128). Both served as useful reference sources for scientists working in radioisotope production worldwide. The 1971 publication has been out of print for quite some time. The IAEA convened a consultants meeting to consider the need for compiling an updated manual. The consultants recommended the publication of an updated manual taking the following into consideration: significant changes have taken place since 1971 in many aspects of radioisotope production; many radioisotopes have been newly introduced while many others have become gradually obsolete; considerable experience and knowledge have been gained in production of important radioisotopes over the years, which can be preserved through compilation of the manual; there is still a need for a comprehensive manual on radioisotope production methods for new entrants to the field, and as a reference. It was also felt that updating all the subjects covered in the 1971 manual at a time may not be practical considering the

  6. Humane Orientation as a New Cultural Dimension of the GLOBE Project

    DEFF Research Database (Denmark)

    Schlösser, Oliver; Frese, Michael; Heintze, Anna-Maria

    2013-01-01

    We validate, extend, and empirically and theoretically criticize the cultural dimension of humane orientation of the project GLOBE (Global Leadership and Organizational Behavior Effectiveness Research Program). Theoretically, humane orientation is not just a one-dimensionally positive concept about...... study used student samples from 25 countries that were either high or low in humane orientation (N = 876) and studied their relation to the traditional GLOBE scale and other cultural-level measures (agreeableness, religiosity, authoritarianism, and welfare state score). Findings revealed a strong...... correlation between humane orientation and agreeableness, welfare state score, and religiosity. Out-group humane orientation proved to be the more relevant subfacet of the original humane orientation construct, suggesting that future research on humane orientation should make use of this measure instead...

  7. 21 CFR 868.1030 - Manual algesimeter.

    Science.gov (United States)

    2010-04-01

    ... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1030 Manual algesimeter. (a) Identification. A manual algesimeter is a mechanical device intended to determine a patient's sensitivity to pain after...

  8. Dimensionality of Women's Career Orientation.

    Science.gov (United States)

    Marshall, Sandra J.; Wijting, Jan P.

    1982-01-01

    Factor analysis of data from two samples identified nine indices of women's career orientation. Two factors accounted for significant variance common to the indices: career centeredness, which reflects the importance attached to a career relative to other life activities, and career commitment, which implies a commitment to lifetime employment.…

  9. Rapid, all-optical crystal orientation imaging of two-dimensional transition metal dichalcogenide monolayers

    International Nuclear Information System (INIS)

    David, Sabrina N.; Zhai, Yao; Zande, Arend M. van der; O'Brien, Kevin; Huang, Pinshane Y.; Chenet, Daniel A.; Hone, James C.; Zhang, Xiang; Yin, Xiaobo

    2015-01-01

    Two-dimensional (2D) atomic materials such as graphene and transition metal dichalcogenides (TMDCs) have attracted significant research and industrial interest for their electronic, optical, mechanical, and thermal properties. While large-area crystal growth techniques such as chemical vapor deposition have been demonstrated, the presence of grain boundaries and orientation of grains arising in such growths substantially affect the physical properties of the materials. There is currently no scalable characterization method for determining these boundaries and orientations over a large sample area. We here present a second-harmonic generation based microscopy technique for rapidly mapping grain orientations and boundaries of 2D TMDCs. We experimentally demonstrate the capability to map large samples to an angular resolution of ±1° with minimal sample preparation and without involved analysis. A direct comparison of the all-optical grain orientation maps against results obtained by diffraction-filtered dark-field transmission electron microscopy plus selected-area electron diffraction on identical TMDC samples is provided. This rapid and accurate tool should enable large-area characterization of TMDC samples for expedited studies of grain boundary effects and the efficient characterization of industrial-scale production techniques

  10. 21 CFR 868.5915 - Manual emergency ventilator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual emergency ventilator. 868.5915 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5915 Manual emergency ventilator. (a) Identification. A manual emergency ventilator is a device, usually incorporating a bag and valve, intended to...

  11. Dental Chairside Technique. Student's Manual.

    Science.gov (United States)

    Apfel, Maura; Weaver, Trudy Karlene

    This manual is part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. This student manual contains four units covering the following topics: local anesthesia; dental office emergencies; oral hygiene;…

  12. Religious orientation and psychological well-being among Spanish undergraduates

    Directory of Open Access Journals (Sweden)

    Joaquín García-Alandete

    2013-06-01

    Full Text Available This paper analyzes the relationship between intrinsic/extrinsic/quest religious orientation and psychological well-being in a sample of 180 Spanish undergraduates, 138 women (76.7% and 42 men (23.3%, aged 18-55, M = 22.91, sD = 6.71. Spanish adaptations of the Batson and Ventis´ Religious Orientation Scaleand the Ryff´s psychological Well-Being Scales were used to this aim. The results of a multiple regression analysis showed (1 a positive relationship between the intrinsic orientation and the psychological well-being measures except for Autonomy, (2 a negative relationship between the extrinsic orientation and Autonomy, and (3 a negative relationship between the quest orientation, Self-acceptance and Purpose in life. The results are discussed in the light of previous researches.

  13. Control of liquid crystal molecular orientation using ultrasound vibration

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Satoki [Faculty of Life and Medical Sciences, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe, Kyoto 610-0321 (Japan); Wave Electronics Research Center, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe, Kyoto 610-0321 (Japan); Koyama, Daisuke; Matsukawa, Mami [Wave Electronics Research Center, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe, Kyoto 610-0321 (Japan); Faculty of Science and Engineering, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe, Kyoto 610-0321 (Japan); Shimizu, Yuki; Emoto, Akira [Faculty of Science and Engineering, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe, Kyoto 610-0321 (Japan); Nakamura, Kentaro [Precision and Intelligence Laboratory, Tokyo Institute of Technology, 4259-R2-26, Nagatsuta-cho, Midori-ku, Yokohama 226-8503 (Japan)

    2016-03-07

    We propose a technique to control the orientation of nematic liquid crystals using ultrasound and investigate the optical characteristics of the oriented samples. An ultrasonic liquid crystal cell with a thickness of 5–25 μm and two ultrasonic lead zirconate titanate transducers was fabricated. By exciting the ultrasonic transducers, the flexural vibration modes were generated on the cell. An acoustic radiation force to the liquid crystal layer was generated, changing the molecular orientation and thus the light transmission. By modulating the ultrasonic driving frequency and voltage, the spatial distribution of the molecular orientation of the liquid crystals could be controlled. The distribution of the transmitted light intensity depends on the thickness of the liquid crystal layer because the acoustic field in the liquid crystal layer is changed by the orientational film.

  14. Study of a magnetically oriented lyotropic mesophase

    International Nuclear Information System (INIS)

    Amaral, L.Q.; Pimentel, C.A.; Tavares, M.R.; Vanin, J.A.

    A study of a magnetically oriented lyomesophase formed by a quaternary system (Na decyl sulfate/water/decanol/ Na sulfate) is reported. Small angle X-ray diffraction measurements have been performed on unoriented samples and samples previously subjected to the action of magnetic fields (H vector). A model of finite planar micelles surrounded by water is proposed [pt

  15. Hydrogen Mixing Studies (HMS), user's manual

    International Nuclear Information System (INIS)

    Lam, K.L.; Wilson, T.L.; Travis, J.R.

    1994-12-01

    Hydrogen Mixing Studies (HMS) is a best-estimate analysis tool for predicting the transport, mixing, and combustion of hydrogen and other gases in nuclear reactor containments and other facilities. It can model geometrically complex facilities having multiple compartments and internal structures. The code can simulate the effects of steam condensation, heat transfer to walls and internal structures, chemical kinetics, and fluid turbulence. The gas mixture may consist of components included in a built-in library of 20 species. HMS is a finite-volume computer code that solves the time-dependent, three-dimensional (3D) compressible Navier Stokes equations. Both Cartesian and cylindrical coordinate systems are available. Transport equations for the fluid internal energy and for gas species densities are also solved. HMS was originally developed to run on Cray-type supercomputers with vector-processing units that greatly improve the computational speed, especially for large, complex problems. Recently the code has been converted to run on Sun workstations. Both the Cray and Sun versions have the same built-in graphics capabilities that allow 1D, 2D, 3D, and time-history plots of all solution variables. Other code features include a restart capability and flexible definitions of initial and time-dependent boundary conditions. This manual describes how to use the code. It explains how to set up the model geometry, define walls and obstacles, and specify gas species and material properties. Definitions of initial and boundary conditions are also described. The manual also describes various physical model and numerical procedure options, as well as how to turn them on. The reader also learns how to specify different outputs, especially graphical display of solution variables. Finally sample problems are included to illustrate some applications of the code. An input deck that illustrates the minimum required data to run HMS is given at the end of this manual

  16. Changing career orientations in higher education: Can HE be a ...

    African Journals Online (AJOL)

    This article reports on a study of the career orientations of the academic staff complement of a tertiary education institution that underwent an intensive organisational transformation process. Career orientation profiles were obtained from a sample of academic staff at the beginning of the organisational change process and ...

  17. Exotic becomes erotic: interpreting the biological correlates of sexual orientation.

    Science.gov (United States)

    Bem, D J

    2000-12-01

    Although biological findings currently dominate the research literature on the determinants of sexual orientation, biological theorizing has not yet spelled out a developmental path by which any of the various biological correlates so far identified might lead to a particular sexual orientation. The Exotic-Becomes-Erotic (EBE) theory of sexual orientation (Bem, 1996) attempts to do just that, by suggesting how biological variables might interact with experiential and sociocultural factors to influence an individual's sexual orientation. Evidence for the theory is reviewed, and a path analysis of data from a large sample of twins is presented which yields preliminary support for the theory's claim that correlations between genetic variables and sexual orientation are mediated by childhood gender nonconformity.

  18. Automating Groundwater Sampling At Hanford, The Next Step

    International Nuclear Information System (INIS)

    Connell, C.W.; Conley, S.F.; Hildebrand, R.D.; Cunningham, D.E.

    2010-01-01

    Historically, the groundwater monitoring activities at the Department of Energy's Hanford Site in southeastern Washington State have been very 'people intensive.' Approximately 1500 wells are sampled each year by field personnel or 'samplers.' These individuals have been issued pre-printed forms showing information about the well(s) for a particular sampling evolution. This information is taken from 2 official electronic databases: the Hanford Well information System (HWIS) and the Hanford Environmental Information System (HEIS). The samplers used these hardcopy forms to document the groundwater samples and well water-levels. After recording the entries in the field, the samplers turned the forms in at the end of the day and other personnel posted the collected information onto a spreadsheet that was then printed and included in a log book. The log book was then used to make manual entries of the new information into the software application(s) for the HEIS and HWIS databases. A pilot project for automating this extremely tedious process was lauched in 2008. Initially, the automation was focused on water-level measurements. Now, the effort is being extended to automate the meta-data associated with collecting groundwater samples. The project allowed electronic forms produced in the field by samplers to be used in a work flow process where the data is transferred to the database and electronic form is filed in managed records - thus eliminating manually completed forms. Elimating the manual forms and streamlining the data entry not only improved the accuracy of the information recorded, but also enhanced the efficiency and sampling capacity of field office personnel.

  19. Geothermal reservoir assessment manual; 1984-1992 nendo chinetsu choryusou hyoka shuhou manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    A geothermal reservoir assessment manual was prepared for the promotion of the development of geothermal power generation, based on the results of the 'geothermal reservoir assessment technique development project' implemented during the fiscal 1984-1992 period and on the results of surveys conducted in Japan and abroad. Of the geothermal systems generally classified into the steam dominant type and the hot water dominant type, encounters with the steam dominant type are but seldom reported. This manual therefore covers the hot water dominant type only. In addition to the explanation of the basic concept and the outline of geothermal reservoirs, the manual carries data necessary for reservoir assessment; geological and geophysical data analyses; geochemistry in reservoir assessment; data of underground logging and of fuming; conceptual models; simulators and models for reservoir simulation; natural-state simulation, history-matching simulation, and reservoir behavior predicting simulation; case history (modeling of a geothermal reservoir prior to exploitation), references, and so forth. (NEDO)

  20. Geothermal reservoir assessment manual; 1984-1992 nendo chinetsu choryusou hyoka shuhou manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    A geothermal reservoir assessment manual was prepared for the promotion of the development of geothermal power generation, based on the results of the 'geothermal reservoir assessment technique development project' implemented during the fiscal 1984-1992 period and on the results of surveys conducted in Japan and abroad. Of the geothermal systems generally classified into the steam dominant type and the hot water dominant type, encounters with the steam dominant type are but seldom reported. This manual therefore covers the hot water dominant type only. In addition to the explanation of the basic concept and the outline of geothermal reservoirs, the manual carries data necessary for reservoir assessment; geological and geophysical data analyses; geochemistry in reservoir assessment; data of underground logging and of fuming; conceptual models; simulators and models for reservoir simulation; natural-state simulation, history-matching simulation, and reservoir behavior predicting simulation; case history (modeling of a geothermal reservoir prior to exploitation), references, and so forth. (NEDO)

  1. The Investigation of Construct Validity of Diagnostic and Statistical Manual of Mental Disorder-5 Personality Traits on Iranian sample with Antisocial and Borderline Personality Disorders.

    Science.gov (United States)

    Amini, Mehdi; Pourshahbaz, Abbas; Mohammadkhani, Parvaneh; Ardakani, Mohammad-Reza Khodaie; Lotfi, Mozhgan

    2014-12-01

    The goal of this study was to examine the construct validity of the diagnostic and statistical manual of mental disorder-5 (DSM-5) conceptual model of antisocial and borderline personality disorders (PDs). More specifically, the aim was to determine whether the DSM-5 five-factor structure of pathological personality trait domains replicated in an independently collected sample that differs culturally from the derivation sample. This study was on a sample of 346 individuals with antisocial (n = 122) and borderline PD (n = 130), and nonclinical subjects (n = 94). Participants randomly selected from prisoners, out-patient, and in-patient clients. Participants were recruited from Tehran prisoners, and clinical psychology and psychiatry clinics of Razi and Taleghani Hospital, Tehran, Iran. The SCID-II-PQ, SCID-II, DSM-5 Personality Trait Rating Form (Clinician's PTRF) were used to diagnosis of PD and to assessment of pathological traits. The data were analyzed by exploratory factor analysis. Factor analysis revealed a 5-factor solution for DSM-5 personality traits. Results showed that DSM-5 has adequate construct validity in Iranian sample with antisocial and borderline PDs. Factors similar in number with the other studies, but different in the content. Exploratory factor analysis revealed five homogeneous components of antisocial and borderline PDs. That may represent personality, behavioral, and affective features central to the disorder. Furthermore, the present study helps understand the adequacy of DSM-5 dimensional approach to evaluation of personality pathology, specifically on Iranian sample.

  2. The investigation of construct validity of diagnostic and statistical manual of mental disorder-5 personality traits on iranian sample with antisocial and borderline personality disorders

    Directory of Open Access Journals (Sweden)

    Mehdi Amini

    2014-01-01

    Full Text Available Background: The goal of this study was to examine the construct validity of the diagnostic and statistical manual of mental disorder-5 (DSM-5 conceptual model of antisocial and borderline personality disorders (PDs. More specifically, the aim was to determine whether the DSM-5 five-factor structure of pathological personality trait domains replicated in an independently collected sample that differs culturally from the derivation sample. Methods: This study was on a sample of 346 individuals with antisocial (n = 122 and borderline PD (n = 130, and nonclinical subjects (n = 94. Participants randomly selected from prisoners, out-patient, and in-patient clients . Participants were recruited from Tehran prisoners, and clinical psychology and psychiatry clinics of Razi and Taleghani Hospital, Tehran, Iran. The SCID-II-PQ, SCID-II, DSM-5 Personality Trait Rating Form (Clinician′s PTRF were used to diagnosis of PD and to assessment of pathological traits. The data were analyzed by exploratory factor analysis. Results: Factor analysis revealed a 5-factor solution for DSM-5 personality traits. Results showed that DSM-5 has adequate construct validity in Iranian sample with antisocial and borderline PDs. Factors similar in number with the other studies, but different in the content. Conclusions: Exploratory factor analysis revealed five homogeneous components of antisocial and borderline PDs. That may represent personality, behavioral, and affective features central to the disorder. Furthermore, the present study helps understand the adequacy of DSM-5 dimensional approach to evaluation of personality pathology, specifically on Iranian sample.

  3. Light-water-reactor hydrogen manual

    International Nuclear Information System (INIS)

    Camp, A.L.; Cummings, J.C.; Sherman, M.P.; Kupiec, C.F.; Healy, R.J.; Caplan, J.S.; Sandhop, J.R.; Saunders, J.H.

    1983-06-01

    A manual concerning the behavior of hydrogen in light water reactors has been prepared. Both normal operations and accident situations are addressed. Topics considered include hydrogen generation, transport and mixing, detection, and combustion, and mitigation. Basic physical and chemical phenomena are described, and plant-specific examples are provided where appropriate. A wide variety of readers, including operators, designers, and NRC staff, will find parts of this manual useful. Different sections are written at different levels, according to the most likely audience. The manual is not intended to provide specific plant procedures, but rather, to provide general guidance that may assist in the development of such procedures

  4. Laterally orienting C. elegans using geometry at microscale for high-throughput visual screens in neurodegeneration and neuronal development studies.

    Directory of Open Access Journals (Sweden)

    Ivan de Carlos Cáceres

    Full Text Available C. elegans is an excellent model system for studying neuroscience using genetics because of its relatively simple nervous system, sequenced genome, and the availability of a large number of transgenic and mutant strains. Recently, microfluidic devices have been used for high-throughput genetic screens, replacing traditional methods of manually handling C. elegans. However, the orientation of nematodes within microfluidic devices is random and often not conducive to inspection, hindering visual analysis and overall throughput. In addition, while previous studies have utilized methods to bias head and tail orientation, none of the existing techniques allow for orientation along the dorso-ventral body axis. Here, we present the design of a simple and robust method for passively orienting worms into lateral body positions in microfluidic devices to facilitate inspection of morphological features with specific dorso-ventral alignments. Using this technique, we can position animals into lateral orientations with up to 84% efficiency, compared to 21% using existing methods. We isolated six mutants with neuronal development or neurodegenerative defects, showing that our technology can be used for on-chip analysis and high-throughput visual screens.

  5. Determination of structure of oriented samples using two-dimensional solid state NMR techniques

    International Nuclear Information System (INIS)

    Jin Hong; Harbison, G.S.

    1990-01-01

    One dimensional and two-dimensional MAS techniques can give detailed information about the structure and dynamics of oriented systems. We describe the application of such techniques to the liquid-crystalline polymer poly(p-phenyleneterphtalimide) (PPTA), and thence deduce the solid-state structure of the material. (author). 9 refs.; 6 figs

  6. 21 CFR 872.6855 - Manual toothbrush.

    Science.gov (United States)

    2010-04-01

    ... remove adherent plaque and food debris from the teeth to reduce tooth decay. (b) Classification. Class I... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6855 Manual toothbrush. (a) Identification. A manual...

  7. The nursing process in crisis-oriented psychiatric home care.

    Science.gov (United States)

    Boomsma, J; Dingemans, C A; Dassen, T W

    1997-08-01

    Crisis-oriented psychiatric home care is a recent development in the Dutch mental health care system. Because of the difference between psychiatric care in the home and in the hospital, an action research project was initiated. This project was directed at the nursing process and the nurses' role and skills in psychiatric home care. The main goal of the project was to describe and to standardize nursing diagnoses and interventions used in crisis-oriented and long-term psychiatric home care. The development of supporting methods of assessment and intervention were also important aspects of this project. In this article a crisis-oriented psychiatric home care programme and the first developmental research activities within this programme are described. To support the nursing process, the development of a nursing record and an assessment-format, based on Gordon's Functional Health Patterns (FHP), took place. By means of content analysis of 61 nursing records, the most frequently stated nursing diagnoses, based upon the North American Nursing Diagnosis Association (NANDA) taxonomy, were identified. The psychiatric diagnostic categories of the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV) were also collected. The most common categories found were those of mood disorders and schizophrenia or psychotic disorders. Seventy-five per cent of the nursing diagnoses showed up within four FHP: role-relationship, coping-stress tolerance, self-perception/self-concept and activity-exercise. The nursing diagnosis of 'ineffective individual coping' was stated most frequently. This is not surprising because of the similarities in the definitions of this nursing diagnosis and the concept of 'crisis' to which the psychiatric home care programme is oriented. Further research activities will be focused on standardization of nursing diagnosis and the interventions that nurses undertake in this type of care.

  8. 14 CFR 125.75 - Airplane flight manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane flight manual. 125.75 Section 125... OPERATIONS: AIRPLANES HAVING A SEATING CAPACITY OF 20 OR MORE PASSENGERS OR A MAXIMUM PAYLOAD CAPACITY OF 6... Airplane flight manual. (a) Each certificate holder shall keep a current approved Airplane Flight Manual or...

  9. Personality Traits, Sexual Problems, and Sexual Orientation: An Empirical Study.

    Science.gov (United States)

    Peixoto, Maria Manuela; Nobre, Pedro

    2016-01-01

    Personality traits, namely neuroticism, have been suggested as vulnerability factors for the development and maintenance of sexual dysfunction in heterosexual samples. However, no evidence was found regarding homosexual samples. This study aimed to analyze the differences on personality traits between heterosexual and homosexual men and women with and without sexual problems. Participants were 285 individuals (142 men, 143 women) who completed a web-based survey. Participants answered the NEO Five-Factor Inventory, the Brief Symptomatology Inventory, and questions regarding sexual problems. The groups of men and women with and without sexual problems were matched for sociodemographic variables. A 2 (Group) × 2 (Sexual Orientation) multivariate analysis of covariance was conducted separately for each gender. Results indicated a significant main effect for group and for sexual orientation in male and female samples. Men with sexual problems scored higher on neuroticism, whereas women with sexual problems scored higher on neuroticism and lower on extraversion when compared with healthy controls, regardless of sexual orientation. In addition, gay men scored higher on neuroticism and lesbian women scored higher on conscientiousness compared with the heterosexual groups. The present findings emphasize the central role of neuroticism on sexual problems in both men and women regardless of sexual orientation.

  10. Kinesiology Workbook and Laboratory Manual.

    Science.gov (United States)

    Harris, Ruth W.

    This manual is written for students in anatomy, kinesiology, or introductory biomechanics courses. The book is divided into two sections, a kinesiology workbook and a laboratory manual. The two sections parallel each other in content and format. Each is divided into three corresponding sections: (1) Anatomical bases for movement description; (2)…

  11. Tank waste remediation system process engineering instruction manual

    International Nuclear Information System (INIS)

    ADAMS, M.R.

    1998-01-01

    The purpose of the Tank Waste Remediation System (TWRS) Process Engineering Instruction Manual is to provide guidance and direction to TWRS Process Engineering staff regarding conduct of business. The objective is to establish a disciplined and consistent approach to business such that the work processes within TWRS Process Engineering are safe, high quality, disciplined, efficient, and consistent with Lockheed Martin Hanford Corporation Policies and Procedures. The sections within this manual are of two types: for compliance and for guidance. For compliance sections are intended to be followed per-the-letter until such time as they are formally changed per Section 2.0 of this manual. For guidance sections are intended to be used by the staff for guidance in the conduct of work where technical judgment and discernment are required. The guidance sections shall also be changed per Section 2.0 of this manual. The required header for each manual section is illustrated in Section 2.0, Manual Change Control procedure. It is intended that this manual be used as a training and indoctrination resource for employees of the TWRS Process Engineering organization. The manual shall be required reading for all TWRS Process Engineering staff, matrixed, and subcontracted employees

  12. WAM-E user's manual

    International Nuclear Information System (INIS)

    Rayes, L.G.; Riley, J.E.

    1986-07-01

    The WAM-E series of mainframe computer codes have been developed to efficiently analyze the large binary models (e.g., fault trees) used to represent the logic relationships within and between the systems of a nuclear power plant or other large, multisystem entity. These codes have found wide application in reliability and safety studies of nuclear power plant systems. There are now nine codes in the WAM-E series, with six (WAMBAM/WAMTAP, WAMCUT, WAMCUT-II, WAMFM, WAMMRG, and SPASM) classified as Type A Production codes and the other three (WAMFTP, WAMTOP, and WAMCONV) classified as Research codes. This document serves as a combined User's Guide, Programmer's Manual, and Theory Reference for the codes, with emphasis on the Production codes. To that end, the manual is divided into four parts: Part I, Introduction; Part II, Theory and Numerics; Part III, WAM-E User's Guide; and Part IV, WAMMRG Programmer's Manual

  13. Nano-scale orientation mapping of graphite in cast irons

    International Nuclear Information System (INIS)

    Theuwissen, Koenraad; Lacaze, Jacques; Véron, Muriel; Laffont, Lydia

    2014-01-01

    A diametrical section of a graphite spheroid from a ductile iron sample was prepared using the focused ion beam-lift out technique. Characterization of this section was carried out through automated crystal orientation mapping in a transmission electron microscope. This new technique automatically collects electron diffraction patterns and matches them with precalculated templates. The results of this investigation are crystal orientation and phase maps of the specimen, which bring new light to the understanding of growth mechanisms of this peculiar graphite morphology. This article shows that mapping the orientation of carbon-based materials such as graphite, which is difficult to achieve with conventional techniques, can be performed automatically and at high spatial resolution using automated crystal orientation mapping in a transmission electron microscope. - Highlights: • ACOM/TEM can be used to study the crystal orientation of carbon-based materials. • A spheroid is formed by conical sectors radiating from a central nuclei. • Misorientations exist within the conical sectors, defining various orientation domains

  14. Effect of substrate crystallographic orientation of garnet-ferrite film properties

    International Nuclear Information System (INIS)

    Burym, Yu.A.; Dubinko, S.V.; Mitsaj, Yu.N.; Borovitskaya, L.N.; Prokopov, A.P.

    1992-01-01

    Samples of garnet-ferrite films with a composition (YbGdPrBi) 3 (FeAlGa) 5 O 12 grown under identical conditions on variously oriented substrates, have been studied. The substrate orientation was changed in such a way that the vector of the substrate normal was in the [110] plane between the [111] and [112] directions. We have found that the substrate misorientation leads to an inclined position of the easy magnetization axis (EMA) and a reduction of the film growth rate. The change of the film physical properties (Faraday rotation, Curie temperature, magnetization) indicates the film composition variation with the substrate orientation change. The temperature dependence of the EMA slope angle in the studied samples is determined by the magnetoelastic contribution to the anisotropy constants. (author)

  15. [Comparison of manual and automated (MagNA Pure) nucleic acid isolation methods in molecular diagnosis of HIV infections].

    Science.gov (United States)

    Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen

    2004-01-01

    Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.

  16. Managerial Accounting. Course Administrative Manual.

    Science.gov (United States)

    Central Michigan Univ., Mount Pleasant. Inst. for Personal and Career Development.

    This manual is part of the materials for a college-level programmed course in managerial accounting and intended to aid instructors in helping students to work their way through the self-instructional study guide around which the course is organized. The manual describes the various materials and components used in the self-instructional sequence…

  17. Measuring market orientation: further evidence on Narver and Slater's three-component scale.

    Science.gov (United States)

    Chakrabarty, Subhra; Rogé, Joseph N

    2003-12-01

    A mail survey of a national random sample of 2,000 marketing managers was conducted. The data provided by 222 respondents were analyzed to assess the dimensionality of Narver and Slater's 15-item measure of market orientation. A confirmatory factor analysis, using LISREL 8.53, provided support for each of the separate dimensions of customer orientation, competitor orientation, and interfunctional coordination. However, a combined 3-factor model of market orientation was not supported. Directions for research are suggested.

  18. The procedures manual of the Environmental Measurements Laboratory. Volume 1, 28. edition

    Energy Technology Data Exchange (ETDEWEB)

    Chieco, N.A. [ed.

    1997-02-01

    This manual covers procedures and technology currently in use at the Environmental Measurements Laboratory. An attempt is made to be sure that all work carried out will be of the highest quality. Attention is focused on the following areas: quality assurance; sampling; radiation measurements; analytical chemistry; radionuclide data; special facilities; and specifications.

  19. Reading Roundup: Rope a Good Book. Louisiana Summer Reading Program, 1995 Manual.

    Science.gov (United States)

    White, Dorothy, J., Ed.

    A manual for the Louisiana Summer Reading Program is presented in 14 sections with a western theme and illustrations. An evaluation form, a 1995 calendar, and a list of audiovisual materials with addresses and prices are also provided. Section 1 discusses promotion, publicity, and programs; and includes sample news releases; program ideas, and…

  20. The procedures manual of the Environmental Measurements Laboratory. Volume 1, 28. edition

    International Nuclear Information System (INIS)

    Chieco, N.A.

    1997-02-01

    This manual covers procedures and technology currently in use at the Environmental Measurements Laboratory. An attempt is made to be sure that all work carried out will be of the highest quality. Attention is focused on the following areas: quality assurance; sampling; radiation measurements; analytical chemistry; radionuclide data; special facilities; and specifications

  1. Exploring the Educational Benefits of Introducing Aspect-Oriented Programming Into a Programming Course

    Science.gov (United States)

    Boticki, I.; Katic, M.; Martin,S.

    2013-01-01

    This paper explores the educational benefits of introducing the aspect-oriented programming paradigm into a programming course in a study on a sample of 75 undergraduate software engineering students. It discusses how using the aspect-oriented paradigm, in addition to the object-oriented programming paradigm, affects students' programs, their exam…

  2. NV/YMP RADIOLOGICAL CONTROL MANUAL

    Energy Technology Data Exchange (ETDEWEB)

    U.S. DEPARTMENT OF ENERGY, NATIONAL NUCLEAR SECURITY ADMINISTRATION NEVADA SITE OFFICE; BECHTEL NEVADA

    2004-11-01

    This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) and the Yucca Mountain Office of Repository Development (YMORD). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations Part 835 (10 CFR 835), Occupational Radiation Protection. Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Pleasanton, California; and at Andrews Air Force Base, Maryland. In addition, field work by NNSA/NSO at other locations is also covered by this manual.

  3. NV/YMP RADIOLOGICAL CONTROL MANUAL

    International Nuclear Information System (INIS)

    2004-01-01

    This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) and the Yucca Mountain Office of Repository Development (YMORD). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations Part 835 (10 CFR 835), Occupational Radiation Protection. Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Pleasanton, California; and at Andrews Air Force Base, Maryland. In addition, field work by NNSA/NSO at other locations is also covered by this manual

  4. Radiological Control Manual. Revision 0, January 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  5. Users Manual for the FEHMN application

    International Nuclear Information System (INIS)

    Zyvoloski, G.A.; Robinson, B.A.; Dash, Z.V.; Trease, L.L.

    1996-01-01

    The user's manual documents the use of the Yucca Mountain Site Characterization Projects Finite element heat and mass transfer code (FEHMN) application. The manual covers: Program considerations, data files, input data, output, system interface, and examples

  6. The effect of aging on physical performance among elderly manual workers

    DEFF Research Database (Denmark)

    Norheim, Kristoffer Larsen; Hjort Bønløkke, Jakob; Samani, Afshin

    2017-01-01

    BACKGROUND: In 2012, the Danish Parliament decided to increase retirement age. Unfortunately, elderly people working in a physically demanding environment may be rendered unable to retain the ability to adequately perform the physical requirements of their jobs, due to age-related decreases...... in physical performance. Therefore, increasing the retirement age may not necessarily lead to the goal of keeping everybody in the labor market for a longer time. To date, our knowledge about the variations in physical performance of the elderly workforce is limited. OBJECTIVE: In this cross-sectional study...... we seek to investigate the effects of aging on physical performance among elderly manual workers. METHODS: Approximately 100 Danish manual workers between 50 and 70 years of age will be recruited. The main measurement outcomes include: (1) inflammatory status from blood samples; (2) body composition...

  7. Manual control models of industrial management

    Science.gov (United States)

    Crossman, E. R. F. W.

    1972-01-01

    The industrial engineer is often required to design and implement control systems and organization for manufacturing and service facilities, to optimize quality, delivery, and yield, and minimize cost. Despite progress in computer science most such systems still employ human operators and managers as real-time control elements. Manual control theory should therefore be applicable to at least some aspects of industrial system design and operations. Formulation of adequate model structures is an essential prerequisite to progress in this area; since real-world production systems invariably include multilevel and multiloop control, and are implemented by timeshared human effort. A modular structure incorporating certain new types of functional element, has been developed. This forms the basis for analysis of an industrial process operation. In this case it appears that managerial controllers operate in a discrete predictive mode based on fast time modelling, with sampling interval related to plant dynamics. Successive aggregation causes reduced response bandwidth and hence increased sampling interval as a function of level.

  8. Gender variance in childhood and sexual orientation in adulthood: a prospective study.

    Science.gov (United States)

    Steensma, Thomas D; van der Ende, Jan; Verhulst, Frank C; Cohen-Kettenis, Peggy T

    2013-11-01

    Several retrospective and prospective studies have reported on the association between childhood gender variance and sexual orientation and gender discomfort in adulthood. In most of the retrospective studies, samples were drawn from the general population. The samples in the prospective studies consisted of clinically referred children. In understanding the extent to which the association applies for the general population, prospective studies using random samples are needed. This prospective study examined the association between childhood gender variance, and sexual orientation and gender discomfort in adulthood in the general population. In 1983, we measured childhood gender variance, in 406 boys and 473 girls. In 2007, sexual orientation and gender discomfort were assessed. Childhood gender variance was measured with two items from the Child Behavior Checklist/4-18. Sexual orientation was measured for four parameters of sexual orientation (attraction, fantasy, behavior, and identity). Gender discomfort was assessed by four questions (unhappiness and/or uncertainty about one's gender, wish or desire to be of the other gender, and consideration of living in the role of the other gender). For both men and women, the presence of childhood gender variance was associated with homosexuality for all four parameters of sexual orientation, but not with bisexuality. The report of adulthood homosexuality was 8 to 15 times higher for participants with a history of gender variance (10.2% to 12.2%), compared to participants without a history of gender variance (1.2% to 1.7%). The presence of childhood gender variance was not significantly associated with gender discomfort in adulthood. This study clearly showed a significant association between childhood gender variance and a homosexual sexual orientation in adulthood in the general population. In contrast to the findings in clinically referred gender-variant children, the presence of a homosexual sexual orientation in

  9. Reduction of Aflatoxins in Apricot Kernels by Electronic and Manual Color Sorting

    Directory of Open Access Journals (Sweden)

    Rosanna Zivoli

    2016-01-01

    Full Text Available The efficacy of color sorting on reducing aflatoxin levels in shelled apricot kernels was assessed. Naturally-contaminated kernels were submitted to an electronic optical sorter or blanched, peeled, and manually sorted to visually identify and sort discolored kernels (dark and spotted from healthy ones. The samples obtained from the two sorting approaches were ground, homogenized, and analysed by HPLC-FLD for their aflatoxin content. A mass balance approach was used to measure the distribution of aflatoxins in the collected fractions. Aflatoxin B1 and B2 were identified and quantitated in all collected fractions at levels ranging from 1.7 to 22,451.5 µg/kg of AFB1 + AFB2, whereas AFG1 and AFG2 were not detected. Excellent results were obtained by manual sorting of peeled kernels since the removal of discolored kernels (2.6%–19.9% of total peeled kernels removed 97.3%–99.5% of total aflatoxins. The combination of peeling and visual/manual separation of discolored kernels is a feasible strategy to remove 97%–99% of aflatoxins accumulated in naturally-contaminated samples. Electronic optical sorter gave highly variable results since the amount of AFB1 + AFB2 measured in rejected fractions (15%–18% of total kernels ranged from 13% to 59% of total aflatoxins. An improved immunoaffinity-based HPLC-FLD method having low limits of detection for the four aflatoxins (0.01–0.05 µg/kg was developed and used to monitor the occurrence of aflatoxins in 47 commercial products containing apricot kernels and/or almonds commercialized in Italy. Low aflatoxin levels were found in 38% of the tested samples and ranged from 0.06 to 1.50 μg/kg for AFB1 and from 0.06 to 1.79 μg/kg for total aflatoxins.

  10. Development of an environmental safety case guidance manual

    International Nuclear Information System (INIS)

    Wellstead, Matthew John

    2014-01-01

    NDA RWMD is currently considering the scope, purpose and structure of a safety case manual that covers the development of nuclear operational, transport and environmental safety cases for a geological disposal facility in the United Kingdom. This paper considers the Environmental Safety Case (ESC) input into such a manual (herein referred to as the 'ESC Manual'), looking at the drivers and benefits that a guidance manual in this area may provide. (authors)

  11. [Customer orientation in ambulant medicine].

    Science.gov (United States)

    Heinrich, M

    2014-07-01

    Due to developments of the health market, economic aspects of the health system are more relevant. In this upcoming market the patient is regarded as customer and the doctor as provider of medical services. Studies on customer orientation in the ambulant medicine lag behind this dynamic. An aim of the study is to comprehend the attitudes of the doctors referring to the customer orientation. In a second step the findings are discussed according to statements of health-care paticipants. Developments in role comprehension of doctor and patient are focused to gain results in scientific and practical applications. Guideline-supported, partly narrative interviews with n=9 gynaecologists and n=11 general practitioners in Freiburg/Germany are recorded, transcribed and reviewed in a qualitative analysis. The statements of the doctors show patient satisfaction has an incremental meaning sspecially regarding the sequence of patient relationship and economic management of the doctor's workplace. The doctor's role comprehension meets with a refusal of the role of salesman and the patient as customer. The method of interviews is suitable to gather empirical impressions of the doctors. The control sample is adequate, however a bias due to inhomogeneous thematic affinitiy and local social-demographics might be possible. The customer orientation has become an important factor in doctor-patient relationtships. The relevance of the doctor-patient conversation and the risk of misuse of the patient confidence are mentioned by the doctors. The doctor as paternalistic care provider gives way to the customer-focused service provider. The doctor's necessity of autonomyssss and dependency on patient satisfaction have potential for conflict. Intensive mention of customer orientation in medicine in the media emphasises its importance. Rational handling with the possibilities of individual health markets is a prospective challange. Further research could be established in all aspects of

  12. CALENDF-2010: user manual

    International Nuclear Information System (INIS)

    Sublet, Jean-Christophe; Ribon, Pierre; Coste-Delclaux, Mireille

    2011-09-01

    CALENDF-2010 represents a Fortran-95 update of the 1994, 2001 then 2005 code distribution with emphasise on programming quality and standards, physics and usage improvements. Devised to process multigroup cross-sections it relies on Gauss quadrature mathematical principle and strength. The followings processes can be handled by the code: moment probability table and effective cross-section calculation; pointwise cross section, probability table and effective cross-section regrouping; probability table condensation; probability table mix for several isotopes; probability table interpolation; effective cross section based probability table calculations; probability table calculations from effective cross-sections; cross-section comparison, complete energy pointwise cross-section processing and thickness dependent averaged transmission sample calculation. The CALENDF user manual, after having listed all principal code functions, describes sequentially each of them and gives comments on their associated output streams. Installation procedures, test cases and running time platform comparisons are given in the appendix. (authors)

  13. On Generalization in Qualitatively Oriented Research

    Directory of Open Access Journals (Sweden)

    Philipp Mayring

    2007-09-01

    Full Text Available In this article, I open a debate about the importance and possibilities of generalization in qualitative oriented research. Generalization traditionally is seen as a central aim of science, as a process of theory formulation for further applications. Others criticize the concept in general, either because of the insufficiency of inductive arguments (POPPER, 1959 or because of context specificity of all scientific findings (LINCOLN & GUBA, 1985. In this paper, I argue that generalization is necessary in qualitative research, but we have to differentiate different aims of generalization: laws, rules, context specific statements, similarities and differences, and procedures. There are different possibilities to arrive at a generalization: analysis of total population, falsification, random or stratified samples, argumentative generalization, theoretical sampling, variation, and triangulation. Depending on the type of research or research design some of those strategies of generalization can be important for qualitative oriented research. This is discussed especially in respect to single case analysis. URN: urn:nbn:de:0114-fqs0703262

  14. Site security personnel training manual

    International Nuclear Information System (INIS)

    1978-10-01

    As required by 10 CFR Part 73, this training manual provides guidance to assist licensees in the development of security personnel training and qualifications programs. The information contained in the manual typifies the level and scope of training for personnel assigned to perform security related tasks and job duties associated with the protection of nuclear fuel cycle facilities and nuclear power reactors

  15. Radiation protection manual

    International Nuclear Information System (INIS)

    Spang, A.

    1983-01-01

    According to the Radiation Protection Ordinance, radiation protection experts directing or supervising the handling of radioactive materials must have expert knowledge. The concept of expert knowledge has been clearly defined by the Fachverband e.V. in a catalogue of instruction goals. The manual follows the principles of this catalogue; it presents the expert knowledge required in a total of 15 subject groups. There is an index which helps the reader to find his specific subject group and the knowledge required of him in this subject group. However, the manual gives only an outline of the subject matter in many instances and should therefore not be regarded as a textbook in the proper sense. (orig./HP) [de

  16. Gravel Roads: Maintenance and Design Manual

    Science.gov (United States)

    This manual was developed with a major emphasis on the maintenance of gravel roads, including some basic design elements. The purpose of the manual is to provide clear and helpful information for doing a better job of maintaining gravel roads.

  17. Sexual orientation and future parenthood in a 2011-2013 nationally representative United States sample.

    Science.gov (United States)

    Riskind, Rachel G; Tornello, Samantha L

    2017-09-01

    Previous researchers have found evidence for differences in parenting goals between lesbian and gay people and their heterosexual peers. However, no previous research has quantified the parenting goals of bisexual people or evaluated parenting goals as a function of sexual partner gender. In addition, political and social climates for sexual minority people had improved rapidly since the last representative data on lesbian and gay peoples' plans for parenthood were collected. We analyzed data from 3,941 childless lesbian, gay, bisexual, and heterosexual participants from the 2011-2013 National Survey of Family Growth (NSFG; United States Department of Health and Human Services, Centers for Disease Control and Prevention, National Center for Health Statistics, 2014), a nationally representative sample of United States residents aged 15 to 44 years. We found that statistically significant, within-gender sexual orientation differences in parenting plans persist, despite social and legal changes. Consistent with hypotheses, bisexual men's parenting desires and intentions were similar to those of their heterosexual male peers and different from those of their gay male peers, while bisexual women's reports were more mixed. Also consistent with hypotheses, the gender of the most recent sexual partner was a strong predictor of parenting goals. We discuss implications for mental and reproductive health-care providers, attorneys, social workers, and others who interact with sexual minority adults. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. The Applicability of Wildlife Value Orientations Scales to a Muslim Student Sample in Malaysia

    NARCIS (Netherlands)

    Jacobs, M.H.; Zainal Abidin, Zulkhairi

    2016-01-01

    This article addresses the applicability of quantitative wildlife value
    orientation scales in Muslim students in Malaysia. As Malaysian culture
    is deeply influenced by Islam ideology, this article presents a
    case for addressing the cross-cultural applicability of the scales.

  19. Objective Assessment of Joint Stiffness: A Clinically Oriented Hardware and Software Device with an Application to the Shoulder Joint

    OpenAIRE

    McQuade, Kevin; Price, Robert; Liu, Nelson; Ciol, Marcia A

    2012-01-01

    Examination of articular joints is largely based on subjective assessment of the “end-feel” of the joint in response to manually applied forces at different joint orientations. This technical report aims to describe the development of an objective method to examine joints in general, with specific application to the shoulder, and suitable for clinical use. We adapted existing hardware and developed laptop-based software to objectively record the force/displacement behavior of the glenohumeral...

  20. Is Customer Orientation of Employees Sustainable? A Moderated Mediation Analysis

    Directory of Open Access Journals (Sweden)

    Junya Cai

    2017-07-01

    Full Text Available While existing literature has addressed the benefits of customer orientation, less is known about its negative outcomes. This study investigates the mediating effect of emotional dissonance on the relationship between customer orientation and unethical decision-making, and whether this mediating effect is moderated by occupation. A sample of 727 doctors and nurses from three Chinese hospitals completed anonymous questionnaires regarding customer orientation, emotional dissonance, and unethical decision-making. Our findings reveal that the positive relationship between customer orientation and unethical decision-making is fully mediated by emotional dissonance. Furthermore, the mediating effect of emotional dissonance is moderated by occupation, which suggests that the mediating effect of emotional dissonance is stronger for doctors. This study contributes to our understanding of how and for whom customer orientation results in unethical decision-making, and suggests the need to take occupation into account in preventing the negative outcomes of customer orientation.

  1. Improvement of upper limb’s condition of women with post mastectomy syndrome with the help of problem-oriented program of physical rehabilitation

    Directory of Open Access Journals (Sweden)

    Y.A. Briskin

    2015-11-01

    Full Text Available Purpose: to determine effectiveness of problem-oriented program of women’s physical rehabilitation with post mastectomy syndrome in improvement of upper limb’s functional state. Material: 50 women with early symptoms of post mastectomy syndrome at stationary rehabilitation stage, who underwent radical mastectomy by Madden were involved in the research. Testing of movement amplitude in shoulder joint, swelling of upper limb and muscular strength of hand’s flexors was conducted on 2 nd day after surgery and at the end of stationary rehabilitation period (12-14 th day. Results: Main means of the authors’ program were: general and special physical exercises; static and dynamic breathing exercises; breathing through preloaded lips, controlled coughing, autogenic drainage, manual pressing, manual vibration; post-isometric relaxation; elements of labor therapy; lymphatic drainage massage and self massage; topical talks; consultations; auto training. The trainings were conducted individually 2-3 times a day; 20-30 minutes every session. The patients’ independent trainings included: fulfillment of therapeutic positions, self-massage, relaxation exercises and auto-training. Conclusions: application of problem-oriented physical rehabilitation program facilitates improvement of upper limb’s functional potentials of women with post mastectomy syndrome.

  2. SANDIA-ORIGEN user's manual

    International Nuclear Information System (INIS)

    Bennett, D.E.

    1979-10-01

    The SANDIA-ORIGEN code calculates the detailed isotopic composition as a function of time in nuclear reactor fuel irradiation and radioactive decay problems. This code was developed specifically for Control Data Corporation computers from the original Oak Ridge National Laboratory ORIGEN code. The nuclear data file used with the code at Sandia Laboratories contains 1063 isotopes (254 structural materials, 101 actinides, and 708 fission products). SANDIA-ORIGEN is oriented toward simple, easy use and includes NAMELIST input, convenient control of the output, and versatile options for the blending and reprocessing of reactor fuel. System operating instructions and the input decks for numerous sample problems are also presented. 13 references, 14 figures

  3. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual radionuclide applicator system. 892.5650.... This generic type of device may include patient and equipment supports, component parts, treatment...

  4. Waste Management Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Buckingham, J.S. [ed.

    1967-08-31

    This Manual has been prepared to provide a documented compendium of the technical bases and general physical features of Isochem Incorporated`s Waste Management Program. The manual is intended to be used as a means of training and as a reference handbook for use by personnel responsible for executing the Waste Management Program. The material in this manual was assembled by members of Isochem`s Chemical Processing Division, Battelle Northwest Laboratory, and Hanford Engineering Services between September 1965 and March 1967. The manual is divided into the following parts: Introduction, contains a summary of the overall Waste Management Program. It is written to provide the reader with a synoptic view and as an aid in understanding the subsequent parts; Feed Material, contains detailed discussion of the type and sources of feed material used in the Waste Management Program, including a chapter on nuclear reactions and the formation of fission products; Waste Fractionization Plant Processing, contains detailed discussions of the processes used in the Waste Fractionization Plant with supporting data and documentation of the technology employed; Waste Fractionization Plant Product and Waste Effluent Handling, contains detailed discussions of the methods of handling the product and waste material generated by the Waste Fractionization Plant; Plant and Equipment, describes the layout of the Waste Management facilities, arrangement of equipment, and individual equipment pieces; Process Control, describes the instruments and analytical methods used for process control; and Safety describes process hazards and the methods used to safeguard against them.

  5. Surface Environmental Surveillance Procedures Manual

    International Nuclear Information System (INIS)

    Hanf, Robert W.; Poston, Ted M.

    2000-01-01

    Shows and explains certain procedures needed for surface environmental surveillance. Hanford Site environmental surveillance is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) under the Surface Environmental Surveillance Project (SESP). The basic requirements for site surveillance are set fourth in DOE Order 5400.1, General Environmental Protection Program Requirements. Guidance for the SESP is provided in DOE Order 5484.1, Environmental Protection, Safety, and Health Protection Information Reporting Requirements and DOE Order 5400.5, Radiation Protection of the Public and Environment. Guidelines for environmental surveillance activities are provided in DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance. An environmental monitoring plan for the Hanford Site is outlined in DOE/RL 91-50 Rev. 2, Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office. Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual. Personnel training requirements are documented in SESP-TP-01 Rev.2, Surface Environmental Surveillance Project Training Program.

  6. US Department of Energy radiological control manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE`s positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements.

  7. MANUAL LOGIC CONTROLLER (MLC)

    OpenAIRE

    Claude Ziad Bayeh

    2015-01-01

    The “Manual Logic Controller” also called MLC, is an electronic circuit invented and designed by the author in 2008, in order to replace the well known PLC (Programmable Logic Controller) in many applications for its advantages and its low cost of fabrication. The function of the MLC is somewhat similar to the well known PLC, but instead of doing it by inserting a written program into the PLC using a computer or specific software inside the PLC, it will be manually programmed in a manner to h...

  8. Security electronics circuits manual

    CERN Document Server

    MARSTON, R M

    1998-01-01

    Security Electronics Circuits Manual is an invaluable guide for engineers and technicians in the security industry. It will also prove to be a useful guide for students and experimenters, as well as providing experienced amateurs and DIY enthusiasts with numerous ideas to protect their homes, businesses and properties.As with all Ray Marston's Circuits Manuals, the style is easy-to-read and non-mathematical, with the emphasis firmly on practical applications, circuits and design ideas. The ICs and other devices used in the practical circuits are modestly priced and readily available ty

  9. Object oriented development of engineering software using CLIPS

    Science.gov (United States)

    Yoon, C. John

    1991-01-01

    Engineering applications involve numeric complexity and manipulations of a large amount of data. Traditionally, numeric computation has been the concern in developing an engineering software. As engineering application software became larger and more complex, management of resources such as data, rather than the numeric complexity, has become the major software design problem. Object oriented design and implementation methodologies can improve the reliability, flexibility, and maintainability of the resulting software; however, some tasks are better solved with the traditional procedural paradigm. The C Language Integrated Production System (CLIPS), with deffunction and defgeneric constructs, supports the procedural paradigm. The natural blending of object oriented and procedural paradigms has been cited as the reason for the popularity of the C++ language. The CLIPS Object Oriented Language's (COOL) object oriented features are more versatile than C++'s. A software design methodology based on object oriented and procedural approaches appropriate for engineering software, and to be implemented in CLIPS was outlined. A method for sensor placement for Space Station Freedom is being implemented in COOL as a sample problem.

  10. Towards Automatic Capturing of Manual Data Processing Provenance

    NARCIS (Netherlands)

    Wombacher, Andreas; Huq, M.R.

    2011-01-01

    Often data processing is not implemented by a work ow system or an integration application but is performed manually by humans along the lines of a more or less specified procedure. Collecting provenance information during manual data processing can not be automated. Further, manual collection of

  11. Unsupervised Ensemble Anomaly Detection Using Time-Periodic Packet Sampling

    Science.gov (United States)

    Uchida, Masato; Nawata, Shuichi; Gu, Yu; Tsuru, Masato; Oie, Yuji

    We propose an anomaly detection method for finding patterns in network traffic that do not conform to legitimate (i.e., normal) behavior. The proposed method trains a baseline model describing the normal behavior of network traffic without using manually labeled traffic data. The trained baseline model is used as the basis for comparison with the audit network traffic. This anomaly detection works in an unsupervised manner through the use of time-periodic packet sampling, which is used in a manner that differs from its intended purpose — the lossy nature of packet sampling is used to extract normal packets from the unlabeled original traffic data. Evaluation using actual traffic traces showed that the proposed method has false positive and false negative rates in the detection of anomalies regarding TCP SYN packets comparable to those of a conventional method that uses manually labeled traffic data to train the baseline model. Performance variation due to the probabilistic nature of sampled traffic data is mitigated by using ensemble anomaly detection that collectively exploits multiple baseline models in parallel. Alarm sensitivity is adjusted for the intended use by using maximum- and minimum-based anomaly detection that effectively take advantage of the performance variations among the multiple baseline models. Testing using actual traffic traces showed that the proposed anomaly detection method performs as well as one using manually labeled traffic data and better than one using randomly sampled (unlabeled) traffic data.

  12. Creating Web Sites The Missing Manual

    CERN Document Server

    MacDonald, Matthew

    2006-01-01

    Think you have to be a technical wizard to build a great web site? Think again. For anyone who wants to create an engaging web site--for either personal or business purposes--Creating Web Sites: The Missing Manual demystifies the process and provides tools, techniques, and expert guidance for developing a professional and reliable web presence. Like every Missing Manual, you can count on Creating Web Sites: The Missing Manual to be entertaining and insightful and complete with all the vital information, clear-headed advice, and detailed instructions you need to master the task at hand. Autho

  13. Sex, Sexual Orientation, and Identification of Positive and Negative Facial Affect

    Science.gov (United States)

    Rahman, Qazi; Wilson, Glenn D.; Abrahams, Sharon

    2004-01-01

    Sex and sexual orientation related differences in processing of happy and sad facial emotions were examined using an experimental facial emotion recognition paradigm with a large sample (N=240). Analysis of covariance (controlling for age and IQ) revealed that women (irrespective of sexual orientation) had faster reaction times than men for…

  14. Comparison of the removal of calcium hydroxide medicaments on the root canal treatment irrigated with manual and sonic agitation technique

    Directory of Open Access Journals (Sweden)

    Anna Muryani

    2017-11-01

    Full Text Available Introduction: Irrigation of the root canal system is an important part of the endodontic treatment principle which aims to improve the hygiene of the root canal system from any debris and medicament residue with the hydrodynamic system. Root irrigation technique can be done with the manual and sonic system by using 2.5% NaOCI irrigation solution. Calcium hydroxide is used as a medicament for root canal sterilization. Root canal treatment will fail due to the imperfect removal of calcium hydroxide residue. The objective of this research was to analyze the comparison of the removal of calcium hydroxide medicaments on the root canal treatment irrigated with manual and sonic agitation technique using 2.5% sodium hypochlorite solution. Methods: The methods used in this study was experimental laboratory. The sample used was 30 maxillary incisors. The teeth were then divided into two groups randomly, then the root canal preparation was done by the crown down technique with manual irrigation using 2.5% NaOCI solution. The radicular part of the teeth was then split longitudinally, given a standardized groove in the one-third of the apical part, then applied with water-solved calcium hydroxide. The teeth were unified afterwards by using flowable composites, then soaked in the artificial saliva at the temperature of 37ºC. The sample of the 1st group was irrigated by manual agitation technique, and the sample of the 2nd group 2 was irrigated by sonic agitation technique, then both were viewed by stereo microscope. The data results were analyzed by Kruskal-Wallis and Mann-Whitney tests. Results: The results of calcium hydroxide removal were different between the root canals that were irrigated using 2.5% sodium hypochlorite irrigation solution by manual agitation technique compared to the sonic agitation technique. Irrigation using 2.5% sodium hypochlorite irrigation solution with the sonic agitation techniques were proven to be more effective in lifting Ca

  15. Using goal orientations to understand motivation in strength training.

    Science.gov (United States)

    Gilson, Todd A; Chow, Graig M; Ewing, Martha E

    2008-07-01

    Despite the importance that today's athletics place on strength training, research exploring the motivation of athletes in this arena is sparse. It is known that not all athletes will use the same motivational cognitions as inspiration, and these differences can be explored through achievement goal orientations. Through questionnaire data and semistructured interviews, the present study investigated how collegiate athletes maintain high levels of motivation over a period of time during strength training and explored relationships among five goal orientations: task-orientation, self-enhancing ego-orientation, self-defeating ego-orientation, social-approval orientation, and work-avoidance orientation. Subjects (N = 133), comprising 90 men and 43 women, were current varsity collegiate athletes from 15 different sports at a major Midwestern university. In addition, using a screener survey to assess achievement goal orientations, 15 subjects from the sample group who demonstrated a stronger inclination to only one achievement goal orientation were interviewed to gain a more in-depth understanding of their motivation cognitions in strength training. Results showed that the strongest achievement goal orientations reported from all athletes were task-orientation and social-approval. Additionally, five higher-order themes (significant others, improvement, competitive demands, being stronger than others, and miscellaneous) were consistent among the interviewed athletes when describing how they stay motivated during strength training. Whereas all athletes were able to describe at least one motivational strategy they employed during strength training, the dominant achievement goal orientation of some athletes influenced their motivational strategy. By employing the T.A.R.G.E.T. model (), strength coaches can foster adaptive achievement goal orientations and thereby enhance intrinsic motivation for athletes engaging in strength training.

  16. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Greulich, K.A.; Gray, C.E. (comp.)

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned.

  17. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    International Nuclear Information System (INIS)

    Greulich, K.A.; Gray, C.E.

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned

  18. IOLMaster versus Manual Keratometry after Photorefractive Keratectomy

    Directory of Open Access Journals (Sweden)

    Hasan Razmju

    2011-01-01

    Full Text Available Purpose: To compare keratometric measurements using a Javal type manual keratometer with IOLMaster in eyes undergoing photorefractive keratectomy (PRK for myopia. Methods: In this comparative case series, we studied patients aged 21 to 27 years scheduled for myopic PRK. Keratometry was performed preoperatively and three months after the procedure using a Javal type manual keratometer and the IOLMaster. We compared postoperative measurements obtained by both instruments with the clinical history method (CHM. Results: Seventy eyes of 35 patients with mean age of 23.45±1.55 years were studied. Mean preoperative spherical equivalent was -4.53±1.3 D. Average preoperative IOLMaster and manual keratometric readings were 45.95±1.23 D and 46.32±1.18 D, respectively. Postoperatively, mean IOLMaster measurements was 38.03±0.68 D and that of manual keratometry was 43.15±1.1 D. Compared to CHM measurements, the 95% limits of agreement were ‑5.95 to -0.85 for the IOLMaster and -1.44 to 4.04 for manual keratometry. Conclusion: Keratometric measurements with the IOLMaster and a Javal type manual device are comparable after PRK; both are largely deviant from the CHM and can yield misleading results.

  19. Occupational position and its relation to mental distress in a random sample of Danish residents

    DEFF Research Database (Denmark)

    Rugulies, Reiner Ernst; Madsen, Ida E H; Nielsen, Maj Britt D

    2010-01-01

    PURPOSE: To analyze the distribution of depressive, anxiety, and somatization symptoms across different occupational positions in a random sample of Danish residents. METHODS: The study sample consisted of 591 Danish residents (50% women), aged 20-65, drawn from an age- and gender-stratified random...... sample of the Danish population. Participants filled out a survey that included the 92 item version of the Hopkins Symptom Checklist (SCL-92). We categorized occupational position into seven groups: high- and low-grade non-manual workers, skilled and unskilled manual workers, high- and low-grade self...

  20. Antigorite crystallographic preferred orientations in serpentinites from Japan

    Science.gov (United States)

    Soda, Yusuke; Wenk, Hans-Rudolf

    2014-03-01

    Foliated antigorite serpentinites are contributing to seismic anisotropy in subduction zones. However, uncertainty remains regarding the development of antigorite crystal preferred orientations (CPO). This study analyzes the CPOs of antigorite and olivine in variably serpentinized samples of antigorite serpentinite from three localities in Southwest Japan, using U-stage, EBSD, and synchrotron X-rays. In all samples (010) poles show a maximum parallel to the lineation, and (001) poles concentrate normal to the foliation with a partial girdle about the lineation. (100) poles are less distinct and scatter widely. The three measurement methods give similar results, though orientation distributions from X-ray analysis which averages over larger sample volumes are more regular and weaker than U-stage and EBSD which focuses on local well-crystallized grains. In olivine-bearing serpentinite, the olivine CPO does not appear to control the antigorite CPO, though there are some topotactic relationships. The antigorite CPO formed contemporaneously with serpentinization and shear deformation. Based on our analyses, in a subduction zone mantle wedge, the (010) pole of antigorite is parallel to the direction of the subduction, and (001) lattice planes are parallel to the interface of the subducting oceanic plate. By averaging single crystal elastic properties over orientation distributions wave velocities have been calculated. Fast P velocities are parallel to the subduction direction and slow velocities are perpendicular to the subducting plate with an anisotropy of 10-15%.

  1. Shape effect related to crystallographic orientation of deformation behavior in copper crystals

    International Nuclear Information System (INIS)

    Kim, K.H.; Chang, C.H.; Koo, Y.M.; MacDowell, A.A.

    1999-01-01

    The deformation behavior of pure copper single crystals has been investigated by scanning electron microscopy and synchrotron radiation using the in situ reflection Laue method. Two types of samples with the same orientation of tensile axes, but with different crystallographic orientations in the directions of the width and thickness of the samples, have been studied. They showed different characteristics of deformation behavior, such as the activated slip systems, the movement of the tensile axis, and the mode of fracture

  2. Incidence rates of surgically treated rhegmatogenous retinal detachment among manual workers, non-manual workers and housewives in Tuscany, Italy

    OpenAIRE

    Curti, Stefania; Coggon, David; Baldasseroni, Alberto; Cooke, Robin M. T.; Fresina, Michela; Campos, Emilio C.; Semeraro, Francesco; Zanardi, Francesca; Farioli, Andrea; Violante, Francesco S.; Mattioli, Stefano

    2013-01-01

    Purpose Candidate risk factors for idiopathic rhegmatogenous retinal detachment (RRD) include heavy manual handling (requiring Valsalva’s maneuver). We assessed incidence rates of surgically treated idiopathic RRD among manual workers, non-manual workers and housewives resident in Tuscany, Italy. Methods We retrieved all hospital discharge records bearing a principal diagnosis corresponding to RRD coupled with retinal surgery for any resident of Tuscany during 1997–2009. After elimination of ...

  3. Military construction program economic analysis manual: Text and appendixes: Hazardous Waste Remedial Actions Program

    International Nuclear Information System (INIS)

    1987-12-01

    This manual enables the US Air Force to comprehensively and systematically analyze alternative approaches to meeting its military construction requirements. The manual includes step-by-step procedures for completing economic analyses for military construction projects, beginning with determining if an analysis is necessary. Instructions and a checklist of the tasks involved for each step are provided; and examples of calculations and illustrations of completed forms are included. The manual explains the major tasks of an economic analysis, including identifying the problem, selecting realistic alternatives for solving it, formulating appropriate assumptions, determining the costs and benefits of the alternatives, comparing the alternatives, testing the sensitivity of major uncertainties, and ranking the alternatives. Appendixes are included that contain data, indexes, and worksheets to aid in performing the economic analyses. For reference, Volume 2 contains sample economic analyses that illustrate how each form is filled out and that include a complete example of the documentation required. 6 figs., 12 tabs

  4. Missouri DECA: 2010-2011 Policy Manual

    Science.gov (United States)

    Missouri Department of Elementary and Secondary Education, 2011

    2011-01-01

    This paper presents the Missouri DECA Policy Manual. This manual contains the following sections: (1) DECA Board of Directors; (2) State Sales Projects; (3) State Officers; (4) Districts; (5) Competitive Events; (6) General Conference Information; (7) Fall Leadership & State Officer Election Conference; (8) Central Region Leadership…

  5. NDS EXFOR manual

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1985-08-01

    EXFOR is the agreed exchange format for the transmission of nuclear reaction data between national and international nuclear data centers for the benefit of nuclear data users in all countries. The IAEA Nuclear Data Section uses the EXFOR system not only for the center-to-center data exchange but also as its data storage and retrieval system. This NDS EXFOR MANUAL therefore contains the agreed EXFOR coding rules and format, supplemented by NDS internal compilation rules. The EXFOR system and the EXFOR nuclear data library with several million data records originate from the cooperation of an increasing number of data centers whose names and addresses can be found inside the Manual. Their contributions and cooperative efforts are gratefully acknowledged. (author)

  6. REBA experimenters' manual

    International Nuclear Information System (INIS)

    Schuch, R.L.

    1977-04-01

    The REBA is a high-energy, pulsed electron beam or bremsstrahlung x-ray generator whose operational purpose is to provide an energy source of short duration for conducting experiments, primarily to determine material responses to rapid surface and in-depth deposition of energy. The purpose of this manual is to serve as a basic source of information for prospective users of REBA. Included is a brief discussion of the design and operation of the facility as well as a summary of output characteristics for electron beam modes and environmental data for x-ray operation. The manual also contains a description of the REBA experimental facilities, including geometry of the test cell, instrumentation and data collection capabilities, and services and support available to experimenters

  7. NDS EXFOR manual

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1996-01-01

    EXFOR is the agreed exchange format for the transmission of nuclear reaction data between national and international nuclear data centers for the benefit of nuclear data users in all countries. The IAEA Nuclear Data Section uses the EXFOR system not only for the center-to-center data exchange but also as its data storage and retrieval system. This NDS EXFOR MANUAL therefore contains the agreed EXFOR coding rules and format, supplemented by NDS internal compilation rules. The EXFOR system and the EXFOR nuclear data library with several million data records originate from the cooperation of an increasing number of data centers whose names and addresses can be found inside the Manual. Their contributions and cooperative efforts are gratefully acknowledged. (author)

  8. Parent-child cultural orientations and child adjustment in Chinese American immigrant families

    OpenAIRE

    Chen, SH; Hua, M; Zhou, Q; Tao, A; Lee, EH; Ly, J; Main, A

    2014-01-01

    Direct and indirect/mediated relations of (a) children's and parents' cultural orientations and (b) parent-child gaps in cultural orientations to children's psychological adjustment were examined in a socioeconomically diverse sample of 258 Chinese American children (age 6-9 years) from immigrant families. Parents reported on children's and their own Chinese and American orientations in language proficiency, media use, and social relationships. Parents and teachers rated children's externaliz...

  9. 21 CFR 866.2180 - Manual colony counter.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter. (a) Identification. A manual colony counter is a device intended for medical purposes that consists...

  10. An Investigation of Bilateral Symmetry During Manual Wheelchair Propulsion.

    Science.gov (United States)

    Soltau, Shelby L; Slowik, Jonathan S; Requejo, Philip S; Mulroy, Sara J; Neptune, Richard R

    2015-01-01

    Studies of manual wheelchair propulsion often assume bilateral symmetry to simplify data collection, processing, and analysis. However, the validity of this assumption is unclear. Most investigations of wheelchair propulsion symmetry have been limited by a relatively small sample size and a focus on a single propulsion condition (e.g., level propulsion at self-selected speed). The purpose of this study was to evaluate bilateral symmetry during manual wheelchair propulsion in a large group of subjects across different propulsion conditions. Three-dimensional kinematics and handrim kinetics along with spatiotemporal variables were collected and processed from 80 subjects with paraplegia while propelling their wheelchairs on a stationary ergometer during three different conditions: level propulsion at their self-selected speed (free), level propulsion at their fastest comfortable speed (fast), and propulsion on an 8% grade at their level, self-selected speed (graded). All kinematic variables had significant side-to-side differences, primarily in the graded condition. Push angle was the only spatiotemporal variable with a significant side-to-side difference, and only during the graded condition. No kinetic variables had significant side-to-side differences. The magnitudes of the kinematic differences were low, with only one difference exceeding 5°. With differences of such small magnitude, the bilateral symmetry assumption appears to be reasonable during manual wheelchair propulsion in subjects without significant upper-extremity pain or impairment. However, larger asymmetries may exist in individuals with secondary injuries and pain in their upper extremity and different etiologies of their neurological impairment.

  11. Biological versus nonbiological older brothers and men's sexual orientation.

    Science.gov (United States)

    Bogaert, Anthony F

    2006-07-11

    The most consistent biodemographic correlate of sexual orientation in men is the number of older brothers (fraternal birth order). The mechanism underlying this effect remains unknown. In this article, I provide a direct test pitting prenatal against postnatal (e.g., social/rearing) mechanisms. Four samples of homosexual and heterosexual men (total n = 944), including one sample of men raised in nonbiological and blended families (e.g., raised with half- or step-siblings or as adoptees) were studied. Only biological older brothers, and not any other sibling characteristic, including nonbiological older brothers, predicted men's sexual orientation, regardless of the amount of time reared with these siblings. These results strongly suggest a prenatal origin to the fraternal birth-order effect.

  12. State Energy Program Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Office of Building Technology, State and Community Programs

    1999-03-17

    The State Energy Program Operations Manual is a reference tool for the states and the program officials at the U.S. Department of Energy's Office of Building Technology, State and Community Programs and Regional Support Offices as well as State Energy Offices. The Manual contains information needed to apply for and administer the State Energy Program, including program history, application rules and requirements, and program administration and monitoring requirements.

  13. Task-oriented lossy compression of magnetic resonance images

    Science.gov (United States)

    Anderson, Mark C.; Atkins, M. Stella; Vaisey, Jacques

    1996-04-01

    A new task-oriented image quality metric is used to quantify the effects of distortion introduced into magnetic resonance images by lossy compression. This metric measures the similarity between a radiologist's manual segmentation of pathological features in the original images and the automated segmentations performed on the original and compressed images. The images are compressed using a general wavelet-based lossy image compression technique, embedded zerotree coding, and segmented using a three-dimensional stochastic model-based tissue segmentation algorithm. The performance of the compression system is then enhanced by compressing different regions of the image volume at different bit rates, guided by prior knowledge about the location of important anatomical regions in the image. Application of the new system to magnetic resonance images is shown to produce compression results superior to the conventional methods, both subjectively and with respect to the segmentation similarity metric.

  14. Manual for a Volunteer Services System.

    Science.gov (United States)

    Helgerson, Linda; And Others

    This manual presents guidelines for planning, monitoring, and controlling the development and operation of volunteer assistance programs. The materials included address questions related to both the process of establishing a volunteer program and the administration of a volunteer management system. The manual is not intended to provide a blueprint…

  15. 21 CFR 886.1770 - Manual refractor.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1770 Manual refractor. (a) Identification. A manual refractor is a device that is a set of lenses of varous dioptric powers intended to measure the refractive error of the eye. (b) Classification. Class I (general controls). The device is exempt from the...

  16. Manual of contracts for the electricity sector. Contracts that work: Drafting and proper legal application. 2. rev. ed.

    International Nuclear Information System (INIS)

    Schoene, Thomas

    2014-01-01

    This manual deals fundamentally with the drafting of contracts for the electricity sector. It covers all types of contracts on both the customer and the network side with their various special clauses and variants, specifically: basic supply, substitute supply, supply contracts for private, commercial and industrial special customers as well as redistributors, EFET contracts, network access contracts, supplier framework contracts, feed-in contracts, grid connection contracts and connection use contracts. The manual also addresses questions concerning electricity customer insolvency, an issue of growing importance. The following topics are furthermore dealt with in a practically oriented manner and with care being taken to explain the underlying legal issues in readily understandable language. What basic framework conditions are specified by the new energy economy laws and general civil law? What possibilities are available in drafting contracts and what are the ramifications in each case? What subject matters in a contract are of particular economic significance? How can concession contracts be designed in a market-conforming way when there is strong competition for qualified rights of way? What opportunities and risks are associated with innovative products? What options for action does a supplier have in the event of (threatening) customer insolvency? Model contracts from day-to-day management practice and tips, checklists and cautioning notes round off this manual.

  17. Ground Snow Measurements: Comparisons of the Hotplate, Weighing and Manual Methods

    Science.gov (United States)

    Wettlaufer, A.; Snider, J.; Campbell, L. S.; Steenburgh, W. J.; Burkhart, M.

    2015-12-01

    The Yankee Environmental Systems (YES) Hotplate was developed to avoid some of the problems associated with weighing snowfall sensors. This work compares Hotplate, weighing sensor (ETI NOAH-II) and manual measurements of liquid-equivalent depth. The main field site was at low altitude in western New York; Hotplate and ETI comparisons were also made at two forested subalpine sites in southeastern Wyoming. The manual measurement (only conducted at the New York site) was derived by weighing snow cores sampled from a snow board. The two recording gauges (Hotplate and ETI) were located within 5 m of the snow board. Hotplate-derived accumulations were corrected using a wind-speed dependent catch efficiency and the ETI orifice was heated and alter shielded. Three important findings are evident from the comparisons: 1) The Yes-derived accumulations, recorded in a user-accessible file, were compared to accumulations derived using an in-house calibration and fundamental measurements (plate power, long and shortwave radiances, wind speed, and temperature). These accumulations are highly correlated (N=24; r2=0.99), but the YES-derived values are larger by 20%. 2) The in-house Hotplate accumulations are in good agreement with ETI-based accumulations but with larger variability (N=24; r2=0.88). 3) The comparison of in-house Hotplate accumulation versus manual accumulation, expressed as mm of liquid, exhibits a fitted linear relationship Y (in-house) versus X (manual) given by Y = -0.2 (±1.4) + 0.9 (±0.1) · X (N= 20; r2=0.89). Thus, these two methods agree within statistical uncertainty.

  18. 21 CFR 890.5180 - Manual patient rotation bed.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5180 Manual patient rotation bed. (a) Identification. A manual patient rotation bed is a device that turns a patient who is... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual patient rotation bed. 890.5180 Section 890...

  19. Orientation Mapping of Extruded Polymeric Composites by Polarized Micro-Raman Spectroscopy

    Directory of Open Access Journals (Sweden)

    Xiaoyun Chen

    2015-01-01

    Full Text Available Molecular orientation has a strong influence on polymeric composite materials’ mechanical properties. In this paper we describe the use of polarized micro-Raman spectroscopy as a powerful tool to map out the molecular orientation of a uniaxially oriented polypropylene- (PP- based composite material. Initial samples exhibited a high degree of surface fibrillation upon cutting. Raman spectroscopy was used to characterize the degree of orientation in the skin and guide the development of the posttreatment process to optimize the skin relaxation while maintaining the high degree of orientation in the rest of the board. The PP oriented polymer composite (OPC was oriented through an extrusion process and its surface was then treated to achieve relaxation. Micro-Raman analysis at the surface region demonstrated the surface orientation relaxation, and the results provide an effective way to correlate the extent of relaxation and process conditions. Larger scale orientation mapping was also carried out over the entire cross-section (12.7 cm × 2.54 cm. The results agree well with prior expectation of the molecular orientation based on the extrusion and subsequent quenching process. The methodologies described here can be readily applied to other polymeric systems.

  20. TV Trouble-Shooting Manual. Volumes 7-8. Part 3: Synchronisation and Deflection Circuits. Student and Instructor's Manuals.

    Science.gov (United States)

    Mukai, Masaaki; Kobayashi, Ryozo

    These volumes are, respectively, the self-instructional student manual and the teacher manual that cover the third set of training topics in this course for television repair technicians. Both contain identical information on synchronization and deflection circuits, including sections on the principle of synchronized deflection, synchronization…

  1. Unraveling the Mechanisms of Manual Therapy: Modeling an Approach.

    Science.gov (United States)

    Bialosky, Joel E; Beneciuk, Jason M; Bishop, Mark D; Coronado, Rogelio A; Penza, Charles W; Simon, Corey B; George, Steven Z

    2018-01-01

    Synopsis Manual therapy interventions are popular among individual health care providers and their patients; however, systematic reviews do not strongly support their effectiveness. Small treatment effect sizes of manual therapy interventions may result from a "one-size-fits-all" approach to treatment. Mechanistic-based treatment approaches to manual therapy offer an intriguing alternative for identifying patients likely to respond to manual therapy. However, the current lack of knowledge of the mechanisms through which manual therapy interventions inhibit pain limits such an approach. The nature of manual therapy interventions further confounds such an approach, as the related mechanisms are likely a complex interaction of factors related to the patient, the provider, and the environment in which the intervention occurs. Therefore, a model to guide both study design and the interpretation of findings is necessary. We have previously proposed a model suggesting that the mechanical force from a manual therapy intervention results in systemic neurophysiological responses leading to pain inhibition. In this clinical commentary, we provide a narrative appraisal of the model and recommendations to advance the study of manual therapy mechanisms. J Orthop Sports Phys Ther 2018;48(1):8-18. doi:10.2519/jospt.2018.7476.

  2. AKURASI HITUNG JUMLAH ERITROSIT METODE MANUAL DAN METODE OTOMATIS

    Directory of Open Access Journals (Sweden)

    Neni Oktiyani

    2017-12-01

    Full Text Available Hitung jumlah eritrosit dilakukan dengan menggunakan metode manual dan metode otomatis. Metode manual menggunakan alat Hemositometer dapat memberikan hasil yang dipercaya dan akurat tergantung keahlian dari teknisi laboratorium. Metode otomatis memberikan hasil yang lebih mudah, cepat dan teliti dibandingkan dengan cara manual. Tujuan penelitian untuk membandingkan akurasi hitung jumlah eritrosit metode manual dan metode otomatis. Jenis penelitian yang digunakan adalah survey analitik dengan rancangan cross sectional. Penelitian ini membandingkan data hasil hitung jumlah eritrosit antara metode manual dengan metode otomatis dengan menggunakan 3 jenis darah kontrol hitung jumlah eritrosit high, normal, dan low dengan 9 kali pengulangan. Hasil penelitian menunjukkan nilai rerata hitung jumlah eritrosit darah kontrol high metode manual sebesar 7,08 juta/µl dengan nilai bias 1,4% dan metode otomatis sebesar 7,03 juta/µl dengan nilai bias 0,7%. Rerata hitung jumlah eritrosit darah kontrol normal metode manual sebesar 4,50 juta/µl dengan nilai bias 0,9% dan metode otomatis sebesar 4,43 juta/µl dengan nilai bias 2,4%. Rerata hitung jumlah eritrosit darah kontrol low metode manual sebesar 1,72 juta/µl dengan nilai bias 4,4% dan metode otomatis sebesar 1,67 juta/µl dengan nilai bias 1,2%. Uji statistik menunjukkan tidak ada perbedaan akurasi yang bermakna antara hitung jumlah eritrosit metode manual dengan metode otomatis.

  3. Sodium safety manual

    International Nuclear Information System (INIS)

    Hayes, D.J.; Gardiner, R.L.

    1980-09-01

    The sodium safety manual is based upon more than a decade of experience with liquid sodium at Berkeley Nuclear Laboratories (BNL). It draws particularly from the expertise and experience developed in the course of research work into sodium fires and sodium water reactions. It draws also on information obtained from the UKAEA and other sodium users. Many of the broad principles will apply to other Establishments but much of the detail is specific to BNL and as a consequence its application at other sites may well be limited. Accidents with sodium are at best unpleasant and at worst lethal in an extremely painful way. The object of this manual is to help prevent sodium accidents. It is not intended to give detailed advice on specific precautions for particular situations, but rather to set out the overall strategy which will ensure that sodium activities will be pursued safely. More detail is generally conveyed to staff by the use of local instructions known as Sodium Working Procedures (SWP's) which are not reproduced in this manual although a list of current SWP's is included. Much attention is properly given to the safe design and operation of larger facilities; nevertheless evidence suggests that sodium accidents most frequently occur in small-scale work particularly in operations associated with sodium cleaning and special care is needed in all such cases. (U.K.)

  4. Equipment Qualification Data Base user manual

    International Nuclear Information System (INIS)

    Decker, Q.R.; Fackrell, L.J.; Fitch, L.R.; Meeky, O.B.

    1985-09-01

    This manual details the Equipment Qualification Data Base (EQDB), its usage, and contents. The EQDB consists of two files; the Plant Qualification File (PQF) and the Equipment Qualification File (EQF). The PQF contains plant specific environmental data and the EQF contains summaries of various test results. Two data management systems are used to manipulate the data and are discussed in this manual. SAS Institute System 2000 (S2K) is the management system for the PQF and Query Update (QU) is the operating system for the EQF. Each management system contains report writers. These writers and how to use them are discussed in detail in this manual

  5. On the development of automatic sample preparation devices

    International Nuclear Information System (INIS)

    Oesselmann, J.

    1987-01-01

    Modern mass spectrometers for stable isotope analysis offer accurate isotope ratio results from gaseous samples (CO 2 , N 2 , H 2 , SO 2 ) in a completely automated fashion. However, most samples of interest either are associated with contaminant gases or the gas has to be liberated by a chemical procedure prior to measurement. In most laboratories this sample preparation step is performed manually. As a consequence, sample throughput is rather low and - despite skilful operation - the preparation procedure varies slightly from one sample to the next affecting mainly the reproducibility of the data. (author)

  6. Design and installation manual for thermal energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Cole, R L; Nield, K J; Rohde, R R; Wolosewicz, R M [eds.

    1979-02-01

    The purpose for this manual is to provide information on the design and installation of thermal energy storage in solar heating systems. It is intended for contractors, installers, solar system designers, engineers, architects, and manufacturers who intend to enter the solar energy business. The reader should have general knowledge of how solar heating systems operate and knowledge of construction methods and building codes. Knowledge of solar analysis methods such as f-chart, SOLCOST, DOE-1, or TRNSYS would be helpful. The information contained in the manual includes sizing storage, choosing a location for the storage device, and insulation requirements. Both air-based and liquid-based systems are covered with topics on designing rock beds, tank types, pump and fan selection, installation, costs, and operation and maintenance. Topics relevant to heating domestic water include safety, single- and dual-tank systems, domestic water heating with air- and liquid-based space heating system, and stand-alone domestic hot water systems. Several appendices present common problems with storage systems and their solutions, heat transfer fluid properties, heat exchanger sizing, and sample specifications for heat exchangers, wooden rock bins, steel tanks, concrete tanks, and fiberglass-reinforced plastic tanks.

  7. TEM Study of the Orientation Relationship Between Cementite and Ferrite in a Bainitic Low Carbon High Strength Low Alloy Steel

    OpenAIRE

    Illescas Fernandez, Silvia; Brown, A.P.; He, K.; Fernández, Javier; Guilemany Casadamon, Josep Maria

    2005-01-01

    Two different bainitic structures are observed in a steel depending on the sample heat treatment. The different types of bainitic structures exhibit different orientation relationships between cementite and the ferrite matrix. Upper bainite presents a Pitsch orientation relationship and lower bainite presents a Bagaryatski orientation relationship. Different heat treatments of low carbon HSLA steel samples have been studied using TEM in order to find the orientation relationshi...

  8. Sierra Structural Dynamics Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Garth M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-19

    Sierra/SD provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Sierra/SD. For a more detailed description of how to use Sierra/SD , we refer the reader to Sierra/SD, User's Notes . Many of the constructs in Sierra/SD are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Sierra/SD are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature. This page intentionally left blank.

  9. Laboratory Waste Disposal Manual. Revised Edition.

    Science.gov (United States)

    Stephenson, F. G., Ed.

    This manual is designed to provide laboratory personnel with information about chemical hazards and ways of disposing of chemical wastes with minimum contamination of the environment. The manual contains a reference chart section which has alphabetical listings of some 1200 chemical substances with information on the health, fire and reactivity…

  10. Manual for Training Leprosy Rehabilitation Workers.

    Science.gov (United States)

    Itoh, Masayoshi; Eason, Alice L.

    The purpose of this manual is to introduce the general concepts and techniques in leprosy rehabilitation to physical therapy aides. Because of the lack of well-trained, qualified, physical therapists, the committee on leprosy rehabilitation considers it necessary to publish a teaching manual outlining leprosy rehabilitation for those who work with…

  11. Beyond the Manual Channel

    DEFF Research Database (Denmark)

    , the main focus there is on spoken languages in their written and spoken forms. This series of workshops, however, offers a forum for researchers focussing on sign languages. For the fourth time, the workshop had sign language corpora as its main topic. This time, the focus was on any aspect beyond...... the manual channel. Not surprisingly, most papers deal with non-manuals on the face. Once again, the papers at this workshop clearly identify the potentials of even closer cooperation between sign linguists and sign language engineers, and we think it is events like this that contribute a lot to a better...

  12. RELAP-7 Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Berry, Ray Alden [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Peterson, John William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Martineau, Richard Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kadioglu, Samet Yucel [Idaho National Lab. (INL), Idaho Falls, ID (United States); Andrs, David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This document summarizes the physical models and mathematical formulations used in the RELAP-7 code. In summary, the MOOSE based RELAP-7 code development is an ongoing effort. The MOOSE framework enables rapid development of the RELAP-7 code. The developmental efforts and results demonstrate that the RELAP-7 project is on a path to success. This theory manual documents the main features implemented into the RELAP-7 code. Because the code is an ongoing development effort, this RELAP-7 Theory Manual will evolve with periodic updates to keep it current with the state of the development, implementation, and model additions/revisions.

  13. Data collection system. Volume 1, Overview and operators manual; Volume 2, Maintenance manual; Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, R.B.; Bauder, M.E.; Boyer, W.B.; French, R.E.; Isidoro, R.J.; Kaestner, P.C.; Perkins, W.G.

    1993-09-01

    Sandia National Laboratories (SNL) Instrumentation Development Department was tasked by the Defense Nuclear Agency (DNA) to record data on Tektronix RTD720 Digitizers on the HUNTERS TROPHY field test conducted at the Nevada Test Site (NTS) on September 18, 1992. This report contains a overview and description of the computer hardware and software that was used to acquire, reduce, and display the data. The document is divided into two volumes: an overview and operators manual (Volume 1) and a maintenance manual (Volume 2).

  14. Difference between manual and digital measurements of dental arches of orthodontic patients.

    Science.gov (United States)

    Jiménez-Gayosso, Sandra Isabel; Lara-Carrillo, Edith; López-González, Saraí; Medina-Solís, Carlo Eduardo; Scougall-Vilchis, Rogelio José; Hernández-Martínez, César Tadeo; Colomé-Ruiz, Gabriel Eduardo; Escoffié-Ramirez, Mauricio

    2018-06-01

    The objective of this study was to compare the differences between the measurements performed manually to those obtained using a digital model scanner of patients with orthodontic treatment.A cross-sectional study was performed in a sample of 30 study models from patients with permanent dentition who attended a university clinic between January 2010 and December 2015. For the digital measurement, a Maestro 3D Ortho Studio scanner (Italy) was used and Mitutoyo electronic Vernier calipers (Kawasaki, Japan) were used for manual measurement. The outcome variables were the measurements for maxillary intercanine width, mandibular intercanine width, maxillary intermolar width, mandibular intermolar width, overjet, overbite, maxillary arch perimeter, mandibular arch perimeter, and palate height. The independent variables, besides age and sex, were a series of arc characteristics. The Student t test, paired Student t test, and Pearson correlation in SPSS version 19 were used for the analysis.Of the models, 60% were from women. Two of nine measurements for pre-treatment and 6 of 9 measurements for post-treatment showed a difference. The variables that were different between the manual and digital measurements in the pre-treatment were maxillary intermolar width and palate height (P manually and digitally showed certain similarities for both vertical and transverse measurements. There are many advantages offered to the orthodontist, such as easy storage; savings in time and space; facilitating the reproducibility of information; and conferring the security of not deteriorating over time. Its main disadvantage is the cost.

  15. Sampling the contents of High-Level Waste tanks

    International Nuclear Information System (INIS)

    Gray, P.L.; Skidmore, V.L.; Bragg, T.K.; Kerrigan, T.

    1993-01-01

    Samples were recently retrieved from a HLW storage tank at the DOE Savannah River Site using simple tools developed for this task. The tools are inexpensive and manually operated, require brief tank open times, and minimize radiation doses

  16. Missing data in substance abuse research? Researchers' reporting practices of sexual orientation and gender identity.

    Science.gov (United States)

    Flentje, Annesa; Bacca, Cristina L; Cochran, Bryan N

    2015-02-01

    Lesbian, gay, bisexual, and transgender individuals are at higher risk for substance use and substance use disorders than heterosexual individuals and are more likely to seek substance use treatment, yet sexual orientation and gender identity are frequently not reported in the research literature. The purpose of this study was to identify if sexual orientation and gender identity are being reported in the recent substance use literature, and if this has changed over time. The PsycINFO and PubMed databases were searched for articles released in 2007 and 2012 using the term "substance abuse" and 200 articles were randomly selected from each time period and database. Articles were coded for the presence or absence of sexual orientation and gender identity information. Participants' sexual orientation was reported in 3.0% and 4.9% of the 2007 and 2.3% and 6.5% of the 2012 sample, in PsycINFO and PubMed sample articles, respectively, while non-binary gender identity was reported in 0% and 1.0% of the 2007 sample and 2.3% and 1.9% of the 2012 PsycINFO and PubMed sample articles. There were no differences in rates of reporting over time. Sexual orientation and gender identity are rarely reported in the substance abuse literature, and there has not been a change in reporting practices between 2007 and 2012. Recommendations for future investigators in reporting sexual orientation and gender identity are included. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Missing data in substance abuse research? Researchers’ reporting practices of sexual orientation and gender identity

    Science.gov (United States)

    Bacca, Cristina L.; Cochran, Bryan N.

    2014-01-01

    Background Lesbian, gay, bisexual, and transgender individuals are at higher risk for substance use and substance use disorders than heterosexual individuals and are more likely to seek substance use treatment, yet sexual orientation and gender identity are frequently not reported in the research literature. The purpose of this study was to identify if sexual orientation and gender identity are being reported in the recent substance use literature, and if this has changed over time. Method The PsycINFO and PubMed databases were searched for articles released in 2007 and 2012 using the term “substance abuse” and 200 articles were randomly selected from each time period and database. Articles were coded for the presence or absence of sexual orientation and gender identity information. Results Participants’ sexual orientation was reported in 3.0% and 4.9% of the 2007 and 2.3% and 6.5% of the 2012 sample, in PsycINFO and PubMed sample articles, respectively, while non-binary gender identity was reported in 0% and 1.0% of the 2007 sample and 2.3% and 1.9% of the 2012 PsycINFO and PubMed sample articles. There were no differences in rates of reporting over time. Conclusions Sexual orientation and gender identity are rarely reported in the substance abuse literature, and there has not been a change in reporting practices between 2007 and 2012. Recommendations for future investigators in reporting sexual orientation and gender identity are included. PMID:25496705

  18. The Comparison of Sport Orientation of Adolescents Based on Perceived Patterning Styles

    Directory of Open Access Journals (Sweden)

    بهروز عبدلی

    2014-03-01

    Full Text Available The purpose of this research was to compare the sport orientation of adolescents based on their perceived patterning styles. Through a two-stage sampling method, 350 junior high school students were selected. A battery of questionnaires was applied to collect the data including parenting style questionnaire, sport orientation questionnaire, and participation motivation questionnaire. Data were analyzed using multivariate analysis of variance (MANOVA. Findings indicated that parenting styles affect children’s sport orientation. In addition, this study shows a signifycant difference between boys and girls in sport orientation, suggesting that boys are more competitive, winning and goal oriented. Consequently, according to the results, children of authoritative parents might be more sport and success oriented than those of permissive parents. In general, the present study reveals that parenting style is a fundamental important process influencing the improvement of adolescents' sport orientation.

  19. Mastering object-oriented Python

    CERN Document Server

    Lott, Steven F

    2014-01-01

    This book follows a standard tutorial approach with approximately 750 code samples spread through the 19 chapters. This amounts to over 5,900 lines of code that illustrate each concept.This book is aimed at programmers who have already learned the basics of object-oriented Python and need to write more sophisticated, flexible code that integrates seamlessly with the rest of Python. This book assumes a computer science background, with experience of common Python design patterns.

  20. Understanding voter orientation in the context of political market orientation

    DEFF Research Database (Denmark)

    Ormrod, Robert P.; Henneberg, Stephan C.

    2010-01-01

    This article develops a conceptual framework and measurement model of political market orientation. The relationships between different behavioural aspects of political market orientation and the attitudinal influences of such behaviour are analysed, and the study includes structural equation...... modelling to test several hypotheses. While the results show that political parties focus on several different aspects of market-oriented behaviour, especially using an internal and societal orientation as cultural antecedents, a more surprising result is the inconclusive effect of a voter orientation...... on political market orientation. This lends support to the argument of 'looking beyond the customer' in political marketing research and practice. The article discusses the findings in the context of the existing literature on political marketing and commercial market orientation....

  1. DEVELOPMENT OF THE DIAGNOSTIC METHOD OF MORAL ORIENTATIONS

    Directory of Open Access Journals (Sweden)

    Irina Sergeevna Slavinskaya

    2015-03-01

    Full Text Available The article outlines the developing and standardization of psychodiagnostics test that measures moral orientations for adolescence. The definition of moral orientations as a matter of diagnosis and the justification of chosen stimuli are provided. Respondents evaluate the degree to which 13 values are expressed in the behavior of seven categories of people (from the «native» to the «enemies». Youthful students from 17 to 21 years (N = 330 were used as a standardization sample. Factorial validity of the scales used was tested by using confirmatory factor analysis (CFA. A hierarchical structure of the test (including the common scale and three subscales is confirmed by the CFA. Cronbach’s alpha indicated a high consistency between separate items of the test, demonstrating high reliability of the test’s scales. Criterion validity of the scales is assessed on the basis of the socio-demographic characteristics of the sample. The convergent and discriminant validity was assessed by establishing close statistical relations with constructs similar in content. The standards for test’s scales are developed. The results testify the adequacy of this method for the diagnosis of youth moral orientations.

  2. Explaining why larks are future-oriented and owls are present-oriented: self-control mediates the chronotype-time perspective relationships.

    Science.gov (United States)

    Milfont, Taciano L; Schwarzenthal, Miriam

    2014-05-01

    Recent studies provide evidence for the chronotype-time perspective relationships. Larks are more future-oriented and owls are more present-oriented. The present study expands this initial research by examining whether the associations are replicable with other time perspective measures, and whether self-control explains the observed relationships. Chronotype was assessed with the Morningness-Eveningness Questionnaire and the basic associations with the Zimbardo Time Perspective Inventory were replicated in a sample of 142 New Zealand students, but not with other measures. Self-control mediated the influence of morningness on both future time perspective and delay of gratification. Implications of the findings are discussed.

  3. Powered bone marrow biopsy procedures produce larger core specimens, with less pain, in less time than with standard manual devices

    Directory of Open Access Journals (Sweden)

    Larry J. Miller

    2011-07-01

    Full Text Available Bone marrow sampling remains essential in the evaluation of hematopoietic and many non-hematopoietic disorders. One common limitation to these procedures is the discomfort experienced by patients. To address whether a Powered biopsy system could reduce discomfort while providing equivalent or better results, we performed a randomized trial in adult volunteers. Twenty-six subjects underwent bilateral biopsies with each device. Core samples were obtained in 66.7% of Manual insertions; 100% of Powered insertions (P=0.002. Initial mean biopsy core lengths were 11.1±4.5 mm for the Manual device; 17.0±6.8 mm for the Powered device (P<0.005. Pathology assessment for the Manual device showed a mean length of 6.1±5.6 mm, width of 1.0±0.7 mm, and volume of 11.0±10.8 mm3. Powered device measurements were mean length of 15.3±6.1 mm, width of 2.0±0.3 mm, and volume of 49.1±21.5 mm3 (P<0.001. The mean time to core ejection was 86 seconds for Manual device; 47 seconds for the Powered device (P<0.001. The mean second look overall pain score was 33.3 for the Manual device; 20.9 for the Powered (P=0.039. We conclude that the Powered biopsy device produces superior sized specimens, with less overall pain, in less time.

  4. Matematica 2. Manual do Professor (Mathematics 2. Teacher's Manual).

    Science.gov (United States)

    D'Alu, Maria Jose Miranda de Sousa

    This teacher's manual accompanies a mathematics textbook for second graders, written in Portuguese. Developed from objectives set forth by the National Portuguese Materials Development Center, it follows closely the objectives and methodology of major curricula used in schools of the United States. Consideration was given to the Portuguese child's…

  5. SAM Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Rui [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-03-01

    The System Analysis Module (SAM) is an advanced and modern system analysis tool being developed at Argonne National Laboratory under the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. SAM development aims for advances in physical modeling, numerical methods, and software engineering to enhance its user experience and usability for reactor transient analyses. To facilitate the code development, SAM utilizes an object-oriented application framework (MOOSE), and its underlying meshing and finite-element library (libMesh) and linear and non-linear solvers (PETSc), to leverage modern advanced software environments and numerical methods. SAM focuses on modeling advanced reactor concepts such as SFRs (sodium fast reactors), LFRs (lead-cooled fast reactors), and FHRs (fluoride-salt-cooled high temperature reactors) or MSRs (molten salt reactors). These advanced concepts are distinguished from light-water reactors in their use of single-phase, low-pressure, high-temperature, and low Prandtl number (sodium and lead) coolants. As a new code development, the initial effort has been focused on modeling and simulation capabilities of heat transfer and single-phase fluid dynamics responses in Sodium-cooled Fast Reactor (SFR) systems. The system-level simulation capabilities of fluid flow and heat transfer in general engineering systems and typical SFRs have been verified and validated. This document provides the theoretical and technical basis of the code to help users understand the underlying physical models (such as governing equations, closure models, and component models), system modeling approaches, numerical discretization and solution methods, and the overall capabilities in SAM. As the code is still under ongoing development, this SAM Theory Manual will be updated periodically to keep it consistent with the state of the development.

  6. Large sexual-orientation-related differences in performance on mental rotation and judgment of line orientation tasks.

    Science.gov (United States)

    Rahman, Qazi; Wilson, Glenn D

    2003-01-01

    This study examined the performance of heterosexual and homosexual men and women on 2 tests of spatial processing, mental rotation (MR) and Benton Judgment of Line Orientation (JLO). The sample comprised 60 heterosexual men, 60 heterosexual women, 60 homosexual men, and 60 homosexual women. There were significant main effects of gender (men achieving higher scores overall) and Gender x Sexual Orientation interactions. Decomposing these interactions revealed large differences between the male groups in favor of heterosexual men on JLO and MR performance. There was a modest difference between the female groups on MR total correct scores in favor of homosexual women but no differences in MR percentage correct. The evidence suggests possible variations in the parietal cortex between homosexual and heterosexual persons.

  7. Parent-Child Cultural Orientations and Child Adjustment in Chinese American Immigrant Families

    Science.gov (United States)

    Chen, Stephen H.; Hua, Michelle; Zhou, Qing; Tao, Annie; Lee, Erica H.; Ly, Jennifer; Main, Alexandra

    2014-01-01

    Direct and indirect/mediated relations of (a) children's and parents' cultural orientations and (b) parent-child gaps in cultural orientations to children's psychological adjustment were examined in a socioeconomically diverse sample of 258 Chinese American children (age = 6-9 years) from immigrant families. Parents reported on children's and…

  8. Study of developing nuclear fabrication facility's integrated emergency response manual

    International Nuclear Information System (INIS)

    Kim, Taeh Yeong; Cho, Nam Chan; Han, Seung Hoon; Moon, Jong Han; Lee, Jin Hang; Min, Guem Young; Han, Ji Ah

    2016-01-01

    Public begin to pay attention to emergency management. Thus, public's consensus on having high level of emergency management system up to advanced country's is reached. In this social atmosphere, manual is considered as key factor to prevent accident or secure business continuity. Therefore, we first define possible crisis at KEPCO Nuclear Fuel (hereinafter KNF) and also make a 'Reaction List' for each crisis situation at the view of information-design. To achieve it, we analyze several country's crisis response manual and then derive component, indicate duties and roles at the information-design point of view. From this, we suggested guideline to make 'Integrated emergency response manual(IERM)'. The manual we used before have following few problems; difficult to applicate at the site, difficult to deliver information. To complement these problems, we searched manual elements from the view of information-design. As a result, we develop administrative manual. Although, this manual could be thought as fragmentary manual because it confined specific several agency/organization and disaster type

  9. Hanford Waste Vitrification Plant technical manual

    Energy Technology Data Exchange (ETDEWEB)

    Larson, D.E. [ed.; Watrous, R.A.; Kruger, O.L. [and others

    1996-03-01

    A key element of the Hanford waste management strategy is the construction of a new facility, the Hanford Waste Vitrification Plant (HWVP), to vitrify existing and future liquid high-level waste produced by defense activities at the Hanford Site. The HWVP mission is to vitrify pretreated waste in borosilicate glass, cast the glass into stainless steel canisters, and store the canisters at the Hanford Site until they are shipped to a federal geological repository. The HWVP Technical Manual (Manual) documents the technical bases of the current HWVP process and provides a physical description of the related equipment and the plant. The immediate purpose of the document is to provide the technical bases for preparation of project baseline documents that will be used to direct the Title 1 and Title 2 design by the A/E, Fluor. The content of the Manual is organized in the following manner. Chapter 1.0 contains the background and context within which the HWVP was designed. Chapter 2.0 describes the site, plant, equipment and supporting services and provides the context for application of the process information in the Manual. Chapter 3.0 provides plant feed and product requirements, which are primary process bases for plant operation. Chapter 4.0 summarizes the technology for each plant process. Chapter 5.0 describes the engineering principles for designing major types of HWVP equipment. Chapter 6.0 describes the general safety aspects of the plant and process to assist in safe and prudent facility operation. Chapter 7.0 includes a description of the waste form qualification program and data. Chapter 8.0 indicates the current status of quality assurance requirements for the Manual. The Appendices provide data that are too extensive to be placed in the main text, such as extensive tables and sets of figures. The Manual is a revision of the 1987 version.

  10. Hanford Waste Vitrification Plant technical manual

    International Nuclear Information System (INIS)

    Larson, D.E.; Watrous, R.A.; Kruger, O.L.

    1996-03-01

    A key element of the Hanford waste management strategy is the construction of a new facility, the Hanford Waste Vitrification Plant (HWVP), to vitrify existing and future liquid high-level waste produced by defense activities at the Hanford Site. The HWVP mission is to vitrify pretreated waste in borosilicate glass, cast the glass into stainless steel canisters, and store the canisters at the Hanford Site until they are shipped to a federal geological repository. The HWVP Technical Manual (Manual) documents the technical bases of the current HWVP process and provides a physical description of the related equipment and the plant. The immediate purpose of the document is to provide the technical bases for preparation of project baseline documents that will be used to direct the Title 1 and Title 2 design by the A/E, Fluor. The content of the Manual is organized in the following manner. Chapter 1.0 contains the background and context within which the HWVP was designed. Chapter 2.0 describes the site, plant, equipment and supporting services and provides the context for application of the process information in the Manual. Chapter 3.0 provides plant feed and product requirements, which are primary process bases for plant operation. Chapter 4.0 summarizes the technology for each plant process. Chapter 5.0 describes the engineering principles for designing major types of HWVP equipment. Chapter 6.0 describes the general safety aspects of the plant and process to assist in safe and prudent facility operation. Chapter 7.0 includes a description of the waste form qualification program and data. Chapter 8.0 indicates the current status of quality assurance requirements for the Manual. The Appendices provide data that are too extensive to be placed in the main text, such as extensive tables and sets of figures. The Manual is a revision of the 1987 version

  11. Crystallographic orientation study of silicon steels using X-ray diffraction, electrons diffraction and the Etch Pit method

    International Nuclear Information System (INIS)

    Santos, Hamilta de Oliveira

    1999-01-01

    The aim of the present study is the microstructural and crystallographic orientation of Fe-3%Si steel. The silicon steel shows good electrical properties and it is used in the nuclear and electrical power fields. The studied steel was supplied by Cia. Acos Especiais Itabira S/A - ACESITA. The material was received in the hot compressed condition, in one or two passes. The hot compressing temperatures used were 900, 1000 and 1100 deg C with soaking times ranging from 32 to 470 s. The material preferential crystallographic orientation was evaluated in every grain of the samples. The characterization techniques used were: scanning electron microscopy (SEM) using the etch pit method; X ray diffraction using the Laue back-reflection method; orientation imaging microscopy (OIM). Microstructural characterization in terms of grain size measurement and mean number of grains in the sample were also undertaken. The Laue method was found an easy technique to access crystallographic orientation of this work polycrystalline samples 2.5 mm average grain size. This was due to the inability to focus the X-rays on a single grain of the material. The scanning electron microscopy showed microcavities left by the etch pit method, which allowed the observation of the crystallographic orientation of each grain from the samples. No conclusive grain crystallographic orientation was possible to obtain by the OIM technique due to the non-existing rolling direction. A more extensive work with the OIM technique must be undertaken on the Fe-3%Si with oriented grains and non oriented grains. (author)

  12. Oregon School Bond Manual. Fourth Edition.

    Science.gov (United States)

    Oregon State Dept. of Education, Salem.

    The manual is intended to guide attorneys and officials of school districts in the issuance and sale of school district bonds. Purchasers of school district bonds rely on the recommendations of accredited bond attorneys who render opinions concerning the validity and legality of bond issues offered for sale. This manual is designed to assist in…

  13. Crystallographic orientations in one-directional gray cast solidification

    International Nuclear Information System (INIS)

    Roviglione, A.; Hermida, J.D.

    1991-01-01

    The aim of this work is to determine the crystallographic orientations of austenite and the A laminar graphite and the compact, in one-directionally grown samples to decide upon the validity of the mentioned theory. (Author) [es

  14. Objective Assessment of Joint Stiffness: A Clinically Oriented Hardware and Software Device with an Application to the Shoulder Joint.

    Science.gov (United States)

    McQuade, Kevin; Price, Robert; Liu, Nelson; Ciol, Marcia A

    2012-08-30

    Examination of articular joints is largely based on subjective assessment of the "end-feel" of the joint in response to manually applied forces at different joint orientations. This technical report aims to describe the development of an objective method to examine joints in general, with specific application to the shoulder, and suitable for clinical use. We adapted existing hardware and developed laptop-based software to objectively record the force/displacement behavior of the glenohumeral joint during three common manual joint examination tests with the arm in six positions. An electromagnetic tracking system recorded three-dimensional positions of sensors attached to a clinician examiner and a patient. A hand-held force transducer recorded manually applied translational forces. The force and joint displacement were time-synchronized and the joint stiffness was calculated as a quantitative representation of the joint "end-feel." A methodology and specific system checks were developed to enhance clinical testing reproducibility and precision. The device and testing protocol were tested on 31 subjects (15 with healthy shoulders, and 16 with a variety of shoulder impairments). Results describe the stiffness responses, and demonstrate the feasibility of using the device and methods in clinical settings.

  15. Multi-shelled q-ball imaging. Moment-based orientation distribution function

    International Nuclear Information System (INIS)

    Umezawa, Eizou; Yamaguchi, Kojiro; Yoshikawa, Mayo; Ohno, Kana; Yoshikawa, Emi

    2010-01-01

    q-ball imaging (QBI) reconstructs the orientation distribution function (ODF) that describes the probability for a spin to diffuse in a given direction, and it is capable of identifying intravoxel multiple fiber orientations. The local maxima of ODF are assumed to indicate fiber orientations, but there is a mismatch between the orientation of a fiber crossing and the local maxima. We propose a novel method, multi-shelled QBI (MS-QBI), that gives a new ODF based on the moment of the probability density function of diffusion displacement. We test the accuracy of the fiber orientation indicated by the new ODF and test fiber tracking using the new ODF. We performed tests using numerical simulation. To test the accuracy of fiber orientation, we assumed that 2 fibers cross and evaluated the deviation of the measured crossing angle from the actual angle. To test the fiber tracking, we used a numerical phantom of the cerebral hemisphere containing the corpus callosum, projection fibers, and superior longitudinal fasciculus. In the tests, we compared the results between MS-QBI and conventional QBI under the condition of approximately equal total numbers of diffusion signal samplings between the 2 methods and chose the interpolation parameter such that the stabilities of the results of the angular deviation for the 2 methods were the same. The absolute value of the mean angular deviation was smaller in MS-QBI than in conventional QBI. Using the moment-based ODF improved the accuracy of fiber pathways in fiber tracking but maintained the stability of the results. MS-QBI can more accurately identify intravoxel multiple fiber orientations than can QBI, without increasing sampling number. The high accuracy of MS-QBI will contribute to the improved tractography. (author)

  16. Texture orientation of glancing angle deposited copper nanowire arrays

    International Nuclear Information System (INIS)

    Alouach, H.; Mankey, G.J.

    2004-01-01

    Self-assembled copper nanowires were deposited on native oxide Si(100) substrates using glancing angle deposition with and without substrate rotation. Wire morphology, texture and crystallographic orientation are strongly dependent on the deposition parameters. A method for determining the preferred crystal orientation is described. This orientation is found to be different from what is expected from the geometric orientation of the wires. For wires deposited without substrate rotation, the face-centered-cubic (fcc)(111) crystal orientation, which corresponds to the close-packed, low surface energy (111) plane of copper, lies between the long axis of the wire and that normal to the substrate. X-ray diffraction data show that the wires exhibit bundling behavior perpendicular to the plane of incidence. For samples deposited with azimuthal rotation of the substrate, the fcc(111) directions in the wires are evenly distributed in a cone around the long axis of the wires, which point normal to the substrate. When the substrate is rotated during deposition at an angle of 75 deg., the wires exhibit a strong fcc(220) texture. These observations show that wires deposited with substrate rotation are highly textured and have random orientations in the plane of the substrate

  17. Tunable photoelectric response in NiO-based heterostructures by various orientations

    Science.gov (United States)

    Luo, Yidong; Qiao, Lina; Zhang, Qinghua; Xu, Haomin; Shen, Yang; Lin, Yuanhua; Nan, Cewen

    2018-02-01

    We engineered various orientations of NiO layers for NiO-based heterostructures (NiO/Au/STO) to investigate their effects on the generation of hot electrons and holes. Our calculation and experimental results suggested that bandgap engineering and the orientation of the hole transport layer (NiO) were crucial elements for the optimization of photoelectric responses. The (100)-orientated NiO/Au/STO achieved the highest photo-current density (˜30 μA/cm2) compared with (111) and (110)-orientated NiO films, which was attributed to the (100) films's lowest effective mass of photogenerated holes (˜1.82 m0) and the highest efficiency of separating and transferring electron-holes of the (100)-orientated sample. Our results opened a direction to design a high efficiency photoelectric solar cell.

  18. Laboratory manual on sample preparation procedures for x-ray micro-analysis

    International Nuclear Information System (INIS)

    1997-01-01

    X-ray micro fluorescence is a non-destructive and sensitive method for studying the microscopic distribution of different elements in almost all kinds of samples. Since the beginning of this century, x-rays and electrons have been used for the analysis of many different kinds of material. Techniques which rely on electrons are mainly developed for microscopic studies, and are used in conventional Electron Microscopy (EM) or Scanning Electron Microscopy (SEM), while x-rays are widely used for chemical analysis at the microscopic level. The first chemical analysis by fluorescence spectroscopy using small x-ray beams was conducted in 1928 by Glockner and Schreiber. Since then much work has been devoted to developing different types of optical systems for focusing an x-ray beam, but the efficiency of these systems is still inferior to the conventional electron optical systems. However, even with a poor optical efficiency, the x-ray microbeam has many advantages compared with electron or proton induced x-ray emission methods. These include: The analyses are non-destructive, losses of mass are negligible, and due to the low thermal loading of x-rays, materials which may be thermally degraded can be analysed; Samples can be analysed in air, and no vacuum is required, therefore specimens with volatile components such as water in biological samples, can be imaged at normal pressure and temperature; No charging occurs during analysis and therefore coating of the sample with a conductive layer is not necessary; With these advantages, simpler sample preparation procedures including mounting and preservation can be used

  19. Hoisting and rigging manual: Uncontrolled document

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-05-01

    This document is a draft copy of a Hoisting and Rigging Manual for the Department of Energy. The manual is divided into ten chapters. The chapter titles follow: terminology and definitions; operator training and qualification; overhead and gantry cranes; mobile cranes; forklift trucks; hoists; hooks; wire rope, slings, and rigging accessories; construction hoisting and rigging equipment requirements; references.

  20. Scanning probe microscopy with vertically oriented cantilevers made easy

    International Nuclear Information System (INIS)

    Valdrè, G; Moro, D; Ulian, G

    2012-01-01

    Non-contact imaging in scanning probe microscopy (SPM) is becoming of great importance in particular for imaging biological matter and in general soft materials. Transverse dynamic force microscopy (TDFM) is an SPM-based methodology that exploiting a cantilever oriented in a vertical configuration with respect to the sample surface may work with very low tip to sample interaction forces. The probe is oscillated parallel to the sample surface, usually by a piezoelectric element. However, this methodology often requires complex microscope setups and detection systems, so it is usually developed in specific laboratories as a prototype microscope. Here, we present a very simple device that easily enables a commercial SPM head to be oriented in such a way to have the cantilever long axis perpendicular to the sample surface. No modifications of the SPM hardware and software are required and commercial available cantilevers can be used as probes. Performance tests using polystyrene spheres, muscovite crystallographic steps and DNA single molecules were successful and all resulted in agreement with other TDFM and SPM observations demonstrating the reliability of the device. (paper)