WorldWideScience

Sample records for sample holders

  1. Transmission electron microscope sample holder with optical features

    Science.gov (United States)

    Milas, Mirko [Port Jefferson, NY; Zhu, Yimei [Stony Brook, NY; Rameau, Jonathan David [Coram, NY

    2012-03-27

    A sample holder for holding a sample to be observed for research purposes, particularly in a transmission electron microscope (TEM), generally includes an external alignment part for directing a light beam in a predetermined beam direction, a sample holder body in optical communication with the external alignment part and a sample support member disposed at a distal end of the sample holder body opposite the external alignment part for holding a sample to be analyzed. The sample holder body defines an internal conduit for the light beam and the sample support member includes a light beam positioner for directing the light beam between the sample holder body and the sample held by the sample support member.

  2. Adjustable Sample Holder With Pressure Contacts for Photoconductivity Measurement

    OpenAIRE

    Sanjeev Kumar

    2011-01-01

    A sample holder is designed to hold and apply pressure contacts on the electrodes of the photoconducting material to study the photoresponse transient. The sample holder is assembled on an aluminium base plate. The needle pointed probes are constrained to move under the spring action to provide the pressure contacts. One of the probes is provided with the facility of ± x directional movement to provide contacts on the samples having different spacing between the electrodes. The setup is simpl...

  3. 3D printing scanning electron microscopy sample holders: A quick and cost effective alternative for custom holder fabrication.

    Science.gov (United States)

    Meloni, Gabriel N; Bertotti, Mauro

    2017-01-01

    A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.

  4. 3D printing scanning electron microscopy sample holders: A quick and cost effective alternative for custom holder fabrication.

    Directory of Open Access Journals (Sweden)

    Gabriel N Meloni

    Full Text Available A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.

  5. Towards a compact and precise sample holder for macromolecular crystallography

    Science.gov (United States)

    Rossi, Christopher; Janocha, Robert; Sorez, Clement; Astruc, Anthony; McCarthy, Andrew; Belrhali, Hassan; Cipriani, Florent

    2017-01-01

    Most of the sample holders currently used in macromolecular crystallography offer limited storage density and poor initial crystal-positioning precision upon mounting on a goniometer. This has now become a limiting factor at high-throughput beamlines, where data collection can be performed in a matter of seconds. Furthermore, this lack of precision limits the potential benefits emerging from automated harvesting systems that could provide crystal-position information which would further enhance alignment at beamlines. This situation provided the motivation for the development of a compact and precise sample holder with corresponding pucks, handling tools and robotic transfer protocols. The development process included four main phases: design, prototype manufacture, testing with a robotic sample changer and validation under real conditions on a beamline. Two sample-holder designs are proposed: NewPin and miniSPINE. They share the same robot gripper and allow the storage of 36 sample holders in uni-puck footprint-style pucks, which represents 252 samples in a dry-shipping dewar commonly used in the field. The pucks are identified with human- and machine-readable codes, as well as with radio-frequency identification (RFID) tags. NewPin offers a crystal-repositioning precision of up to 10 µm but requires a specific goniometer socket. The storage density could reach 64 samples using a special puck designed for fully robotic handling. miniSPINE is less precise but uses a goniometer mount compatible with the current SPINE standard. miniSPINE is proposed for the first implementation of the new standard, since it is easier to integrate at beamlines. An upgraded version of the SPINE sample holder with a corresponding puck named SPINEplus is also proposed in order to offer a homogenous and interoperable system. The project involved several European synchrotrons and industrial companies in the fields of consumables and sample-changer robotics. Manual handling of mini

  6. Tem holder for sample transfer under reaction conditions

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Wagner, Jakob Birkedal

    and temperature, which usually are far from the operando conditions of e.g. heterogeneous catalysis. Our efforts focus on bridging these gaps by establishing in situ sample transfer between complementary measurement techniques. To fully exploit the capabilities of ETEM complementary experiments...... and characterization techniques are beneficial. Normally, the complementary measurements are done in parallel with experiments separated in time and space [3] or by mimicking a reactor bed by changing the feed gas composition according to reactivity and conversion measured in dedicated catalyst set-ups [4......]. Furthermore, dedicated transfer holders have been used to transfer catalyst samples between reactor set-ups and TEM at room temperature in inert atmosphere [5]. To take the full advantage of complementary in situ techniques, transfer under reactions conditions is essential. This study introduces the in situ...

  7. A sample holder for the study of isothermal heat of hydration of cement

    DEFF Research Database (Denmark)

    Hansen, Per Freiesleben; Jensen, Ole Mejlhede

    1998-01-01

    Different techniques for measuring heat of hydration of cement are discussed, and a sample holder designed specially for measuring isothermal heat of hydration is described. A particular characteristic of the sample holder is the vacuum mixing technique which ensures a momentary and homogeneous...

  8. A sample holder for in-house X-ray powder diffraction studies of protein powders

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl; Harris, Pernille; Ståhl, Kenny

    2011-01-01

    A sample holder for handling samples of protein for in-house X-ray powder diffraction (XRPD) analysis has been made and tested on lysozyme. The use of an integrated pinhole reduced the background, and good signal-to-noise ratios were obtained from only 7 l of sample, corresponding to approximately...... 2-3 mg of dry protein. The sample holder is further adaptable to X-ray absorption spectroscopy (XAS) measurements. Both XRPD and XAS at the Zn K-edge were tested with hexameric Zn insulin....

  9. Magnetic measurements with a SQUID magnetometer: Possible artifacts induced by sample-holder off-centering

    Science.gov (United States)

    Casañ-Pastor, Nieves; Gomez-Romero, Pedro; Baker, Louis C. W.

    1991-04-01

    Asymmetries in sample holders used for magnetic measurements on magnetometers based on induction methods, such as those equipped with SQUID sensors, can lead to substantial errors and/or important artifacts which resemble phase transitions. They occur under the conditions for which sample and/holder have signals of opposite sign, but are nearly equal in magnitude. The most serious errors can occur often, but not exclusively, for compounds having intermediate magnetic dilution. We present here a general discussion of the problem illustrated by measurements of a polyoxometallate with the known Keggin structure K6[Fe(III)W12O40]ṡnH2O, done on a SHE VTS model 905. While one of the obvious solutions to this problem is the use of holders with a signal much smaller than that of the sample, it would be preferable if, in addition, the holder had a response of the same sign as that of the sample, for all temperatures and fields measured.

  10. An evaluation of adhesive sample holders for advanced crystallographic experiments

    Science.gov (United States)

    Mazzorana, Marco; Sanchez-Weatherby, Juan; Sandy, James; Lobley, Carina M. C.; Sorensen, Thomas

    2014-01-01

    The hydration state of macromolecular crystals often affects their overall order and, ultimately, the quality of the X-ray diffraction pattern that they produce. Post-crystallization techniques that alter the solvent content of a crystal may induce rearrangement within the three-dimensional array making up the crystal, possibly resulting in more ordered packing. The hydration state of a crystal can be manipulated by exposing it to a stream of air at controlled relative humidity in which the crystal can equilibrate. This approach provides a way of exploring crystal hydration space to assess the diffraction capabilities of existing crystals. A key requirement of these experiments is to expose the crystal directly to the dehydrating environment by having the minimum amount of residual mother liquor around it. This is usually achieved by placing the crystal on a flat porous support (Kapton mesh) and removing excess liquid by wicking. Here, an alternative approach is considered whereby crystals are harvested using adhesives that capture naked crystals directly from their crystallization drop, reducing the process to a one-step procedure. The impact of using adhesives to ease the harvesting of different types of crystals is presented together with their contribution to background scattering and their usefulness in dehydration experiments. It is concluded that adhesive supports represent a valuable tool for mounting macromolecular crystals to be used in humidity-controlled experiments and to improve signal-to-noise ratios in diffraction experiments, and how they can protect crystals from modifications in the sample environment is discussed. PMID:25195752

  11. An instrumented sample holder for time-lapse microtomography measurements of snow under advective airflow

    Directory of Open Access Journals (Sweden)

    P. P. Ebner

    2014-09-01

    Full Text Available An instrumented sample holder was developed for time-lapse microtomography of snow samples to enable in situ nondestructive spatial and temporal measurements under controlled advective airflows, temperature gradients, and air humidities. The design was aided by computational fluid dynamics simulations to evaluate the airflow uniformity across the snow sample. Morphological and mass transport properties were evaluated during a 4-day test run. This instrument allows the experimental characterization of metamorphism of snow undergoing structural changes with time.

  12. A Spaceflight Experiment to Determine the Effect of Chamfered Sample Holders on Atomic Oxygen Erosion

    Science.gov (United States)

    Girish, Kshama; Banks, Bruce A.; De Groh, Kim K.

    2017-01-01

    The exteriors of low Earth orbit (LEO) spacecraft are subjected to many environmental threats that can cause the surface materials to degrade. One of these threats is atomic oxygen (AO), which is formed by photo dissociation of molecular oxygen by energetic UV radiation. Atomic oxygen exposure can result in oxidative erosion of polymers leading to structural or thermal failure of spacecraft components. The amount of AO erosion expected during a mission can be calculated by knowing the AO erosion yield (Ey, volume loss per incident atom) of the material and the AO fluence expected for the mission. The Ey can be determined through dehydrated mass loss measurements of test samples if one knows the AO fluence, density, and exposure area. Such measurements have been made as part of flight experiments, including the Materials International Space Station Experiment 2 (MISSE 2) Polymers Experiment. The MISSE 2 Polymers Experiment sample holders had chamfered circular apertures that controlled the exposure area, but also allowed some additional AO to scatter from the chamfered edges onto the samples thus causing some samples to erode thru and peel at their perimeter due to this scattering effect. By modeling the scattered AO flux one can predict the actual total AO fluence, and hence more accurate sample Ey. Sample holders with different chamfered-perimeter to exposed-area ratios have been designed for future spaceflight experiments that allow a more accurate determination of the Ey for large area polymers, representative of their use on spacecraft surfaces.

  13. OMNY PIN—A versatile sample holder for tomographic measurements at room and cryogenic temperatures

    Science.gov (United States)

    Holler, M.; Raabe, J.; Wepf, R.; Shahmoradian, S. H.; Diaz, A.; Sarafimov, B.; Lachat, T.; Walther, H.; Vitins, M.

    2017-11-01

    Nowadays ptychographic tomography in the hard x-ray regime, i.e., at energies above about 2 keV, is a well-established measurement technique. At the Paul Scherrer Institut, currently two instruments are available: one is measuring at room temperature and atmospheric pressure, and the other, the so-called OMNY (tOMography Nano crYo) instrument, is operating at ultra-high vacuum and offering cryogenic sample temperatures down to 10 K. In this manuscript, we present the sample mounts that were developed for these instruments. Aside from excellent mechanical stability and thermal conductivity, they also offer highly reproducible mounting. Various types were developed for different kinds of samples and are presented in detail, including examples of how specimens can be mounted on these holders. We also show the first hard x-ray ptychographic tomography measurements of high-pressure frozen biological samples, in the present case Chlamydomonas cells, the related sample pins and preparation steps. For completeness, we present accessories such as transportation containers for both room temperature and cryogenic samples and a gripper mechanism for automatic sample changing. The sample mounts are not limited to x-ray tomography or hard x-ray energies, and we believe that they can be very useful for other instrumentation projects.

  14. Practical soil analysis by laser induced breakdown spectroscopy employing subtarget supported micro mesh as a powder sample holder

    Science.gov (United States)

    Suyanto, Hery; Lie, Tjung Jie; Kurniawan, Koo Hendrik; Kagawa, Kiichiro; Tjia, May On

    2017-11-01

    A practical alternative of sample preparation technique is proposed for direct powder analysis using laser-induced breakdown spectroscopy (LIBS) instead of the commonly adopted treatment of pelletizing the powder. The resulted pellet is known to suffer from reduced sensitivity of emission. Besides, it may also give rise to interfering effect from the binder emission. We introduce in this report a more practical technique of using a subtarget supported micro mesh (SSMM) powder sample holder. The LIBS spectrum of standard soil powder measured with 13 mJ 1064 nm Nd:YAG laser in 0.65 kPa ambient air is shown to exhibit the sharp emission lines of all the major elements in the sample. A comparison with the emission spectra measured from the pelletized powder, the spectrum obtained using the SSMM sample holder shows distinctly superior spectral quality marked by the absence of matrix effect found in pelletized powder samples, and the much stronger intensity due to the more effective shock wave plasma induced thermal excitation process produced by the hard subtarget in the sample holder. Repeating the measurement on a number of the standard soil samples of various Pb contents is shown to yield a linear calibration line with practically zero intercept and a detection limit of less than 10 ppm. We have thus demonstrated the viability of the proposed powder sample holder for the development of practical and quantitative powder analysis in the field.

  15. Implementation of a Light Source in a TEM Sample Holder for In-situ Studies of Photocatalytic Materials

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    Photocatalysts are of fundamental interest for sustainable energy research [1]. By means of transmission electron microscopy (TEM) it is possible to obtain insight into the structure, composition and reactivity of photocatalysts. Such insight can be used for their further optimization [2]. We have...... can be used inside an environmental TEM (ETEM) allowing specimens to be analyzed during exposure to a controlled gas atmosphere and illumination. The holder is presently being used to study a variety of photoreactive materials and structures, including photocatalysts, photonic devices and solar cells...... constructed a specimen holder capable of shining light onto samples inside the TEM. The holder contains a laser diode and an optical system that guides light onto a sample with maximum power transmission. The source can be changed and tuned, in principle spanning the whole visible and UV spectrum. The device...

  16. Self-calibrating lensless inline-holographic microscopy by a sample holder with reference structures.

    Science.gov (United States)

    Riesenberg, Rainer; Kanka, Mario

    2014-09-01

    A self-calibration technique for lensless compact chip-microscopes based on inline holography with pinhole illumination is presented. The pinhole illumination wave acts as reference and is needed for the reconstruction process. This reference wave is assumed to be spherical, so that its phase is already determined by the position of the pinhole in relation to the image sensor. It is shown that the reconstructed spatial resolution is strongly dependent on the estimation for the pinhole to sensor distance. A precision in the range of tens of microns was reached for microscopic imaging with a spatial resolution in the range of one micron. Therefore additional reference crosses are prepared lithographically on the sample holder. The hologram, which contains the optical information about the sample as well as the reference crosses, is used for calibration and image reconstruction at the same time. The presented technique was tested to allow the reconstruction of a spatial resolution corresponding to the limit of detection apertures of about 0.66. The technique was applied to holograms of test beads and blood smear samples.

  17. Gritty Surface Sample Holder Invented To Obtain Correct X-ray Absorption Fine Structure Spectra for Concentrated Materials by Fluorescence Yield.

    Science.gov (United States)

    Abe, Hitoshi; Niwa, Yasuhiro; Kimura, Masao; Murakami, Youichi; Yokoyama, Toshiharu; Hosono, Hideo

    2016-04-05

    A gritty surface sample holder has been invented to obtain correct XAFS spectra for concentrated samples by fluorescence yield (FY). Materials are usually mixed with boron nitride (BN) to prepare proper concentrations to measure XAFS spectra. Some materials, however, could not be mixed with BN and would be measured in too concentrated conditions to obtain correct XAFS spectra. Consequently, XAFS spectra will be incorrect typically with decreased intensities of the peaks. We have invented the gritty surface sample holders to obtain correct XAFS spectra even for concentrated materials for FY measurements. Pure Cu and CuO powders were measured mounted on the sample holders, and the same spectra were obtained as transmission spectra of properly prepared samples. This sample holder is useful to measure XAFS for any concentrated materials.

  18. Low conductive support for thermal insulation of a sample holder of a variable temperature scanning tunneling microscope.

    Science.gov (United States)

    Hanzelka, Pavel; Vonka, Jakub; Musilova, Vera

    2013-08-01

    We have designed a supporting system to fix a sample holder of a scanning tunneling microscope in an UHV chamber at room temperature. The microscope will operate down to a temperature of 20 K. Low thermal conductance, high mechanical stiffness, and small dimensions are the main features of the supporting system. Three sets of four glass balls placed in vertices of a tetrahedron are used for thermal insulation based on small contact areas between the glass balls. We have analyzed the thermal conductivity of the contacts between the balls mutually and between a ball and a metallic plate while the results have been applied to the entire support. The calculation based on a simple model of the setup has been verified with some experimental measurements. In comparison with other feasible supporting structures, the designed support has the lowest thermal conductance.

  19. Nonwoven polypropylene as a novel extractant phase holder for the determination of insecticides in environmental water samples.

    Science.gov (United States)

    Hu, Lu; Li, Songqing; Zhang, Panjie; Yang, Xiaoling; Yang, Miyi; Lu, Runhua; Gao, Haixiang

    2014-09-01

    In this work, a novel liquid-phase microextraction approach using nonwoven polypropylene as the extraction solvent holder was developed. Nonwoven polypropylene, a hydrophobic material, is widely used in the cleanup of oil spills. Due to its large surface area, efficient, and full extraction can be achieved. Nonwoven polypropylene containing an ionic liquid was used to extract benzoylurea insecticides (diflubenzuron, teflubenzuron, flufenoxuron, and chlorfluazuron) through vortex-assisted liquid-liquid microextraction. The parameters that affected the extraction efficiency included the type and volume of the extractant, the extraction time, the time and solvent volume for desorption and the mass and surface area of the nonwoven polypropylene. Under the optimized conditions, good linearity was obtained, with coefficients of determination greater than 0.9996, and the limit of detections of these compounds, calculated at S/N = 3, were in the range of 0.73-5.0 ng/mL. The recoveries of the four insecticides at two spiked levels ranged from 93.3 to 102.0%, with relative standard deviations of less than 4.0%. The proposed method was then successfully used for the rapid determination of benzoylurea insecticides in spiked real water samples before liquid chromatographic analysis. The procedure is simple, inexpensive, easy to execute, and can be widely used. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Design of sample holder for in operando XAS of oxidation state changes in La1−xSrxMnO3±δ electrodes

    DEFF Research Database (Denmark)

    Traulsen, Marie Lund

    2014-01-01

    The design and construction of a sample holder for in operando X-ray absorption spectroscopy on solid oxide electrodes, like for instance the lanthanum strontium manganite electrodes, is explained. The sample holder is mounted in a test-cell, which is also described together with some preliminary...

  1. Development and Application of a Sample Holder for In Situ Gaseous TEM Studies of Membrane Electrode Assemblies for Polymer Electrolyte Fuel Cells.

    Science.gov (United States)

    Kamino, Takeo; Yaguchi, Toshie; Shimizu, Takahiro

    2017-10-01

    Polymer electrolyte fuel cells hold great potential for stationary and mobile applications due to high power density and low operating temperature. However, the structural changes during electrochemical reactions are not well understood. In this article, we detail the development of the sample holder equipped with gas injectors and electric conductors and its application to a membrane electrode assembly of a polymer electrolyte fuel cell. Hydrogen and oxygen gases were simultaneously sprayed on the surfaces of the anode and cathode catalysts of the membrane electrode assembly sample, respectively, and observation of the structural changes in the catalysts were simultaneously carried out along with measurement of the generated voltages.

  2. Phase angle and impedance measurements for nondestructive moisture content determination of in-shell peanuts using a cylindrical sample holder

    Science.gov (United States)

    A simple, low cost instrument that measures impedance and phase angle was used along with a parallel-plate capacitance system to estimate the moisture content (MC) of yellow corn. A sample of corn weighing about 100g was placed between the parallel-plate electrodes and the impedance and phase angle...

  3. ADJUSTABLE CHIP HOLDER

    DEFF Research Database (Denmark)

    2009-01-01

    An adjustable microchip holder for holding a microchip is provided having a plurality of displaceable interconnection pads for connecting the connection holes of a microchip with one or more external devices or equipment. The adjustable microchip holder can fit different sizes of microchips with ...

  4. 3D printed sample holder for in-operando EPR spectroscopy on high temperature polymer electrolyte fuel cells

    Science.gov (United States)

    Niemöller, Arvid; Jakes, Peter; Kayser, Steffen; Lin, Yu; Lehnert, Werner; Granwehr, Josef

    2016-08-01

    Electrochemical cells contain electrically conductive components, which causes various problems if such a cell is analyzed during operation in an EPR resonator. The optimum cell design strongly depends on the application and it is necessary to make certain compromises that need to be individually arranged. Rapid prototyping presents a straightforward option to implement a variable cell design that can be easily adapted to changing requirements. In this communication, it is demonstrated that sample containers produced by 3D printing are suitable for EPR applications, with a particular emphasis on electrochemical applications. The housing of a high temperature polymer electrolyte fuel cell (HT-PEFC) with a phosphoric acid doped polybenzimidazole membrane was prepared from polycarbonate by 3D printing. Using a custom glass Dewar, this fuel cell could be operated at temperatures up to 140 °C in a standard EPR cavity. The carbon-based gas diffusion layer showed an EPR signal with a characteristic Dysonian line shape, whose evolution could be monitored in-operando in a non-invasive manner.

  5. Evaluation of sample holders designed for long-lasting X-ray micro-tomographic scans of ex-vivo soft tissue samples

    Science.gov (United States)

    Dudak, J.; Zemlicka, J.; Krejci, F.; Karch, J.; Patzelt, M.; Zach, P.; Sykora, V.; Mrzilkova, J.

    2016-03-01

    X-ray microradiography and microtomography are imaging techniques with increasing applicability in the field of biomedical and preclinical research. Application of hybrid pixel detector Timepix enables to obtain very high contrast of low attenuating materials such as soft biological tissue. However X-ray imaging of ex-vivo soft tissue samples is a difficult task due to its structural instability. Ex-vivo biological tissue is prone to fast drying-out which is connected with undesired changes of sample size and shape producing later on artefacts within the tomographic reconstruction. In this work we present the optimization of our Timepix equipped micro-CT system aiming to maintain soft tissue sample in stable condition. Thanks to the suggested approach higher contrast of tomographic reconstructions can be achieved while also large samples that require detector scanning can be easily measured.

  6. Novel Laparoscopic Needle Holder

    Directory of Open Access Journals (Sweden)

    Chien Han-Min

    2016-01-01

    Full Text Available This paper presents a new design of laparoscopic needle holder, which is able to reduce the laparoscopy operating time. Many reports showed that laparoscopic technique provide many benefits to patients, however, it also bring many disadvantages to surgeons. In contrast to conventional surgery, there are several disadvantages to this technique; these include restricted vision, image distortions, difficulty of hand-eye coordination and poor instrument design resulting to a higher probability of getting musculoskeletal disorders compared to conventional surgical procedures. The new design will be the one of solution to improve surgeons’ quality of life.

  7. Gender differentials in market participation among small-holder ...

    African Journals Online (AJOL)

    holder cassava farmers in south-eastern Nigeria by the use of a multistage randomised sampling procedure from 360 farmers. The results show that important variables directly related to participating and level of sales in cassava markets were ...

  8. Freeze Protection in Gas Holders

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Duursma, Gail

    In cold weather, the water seals of gasholders need protection from freez- ing to avoid compromising the seal. These holders have a large reservoir of “tank water” at the base which is below ground. At present freeze- protection is achieved by external heating of the seal water which is in a slot...

  9. Working electrode holder and electrochemical cell

    DEFF Research Database (Denmark)

    2016-01-01

    The present disclosure relates to a holder for a test object, more specifically to a holder for measuring electrochemical properties of the test object. One embodiment relates to a working electrode holder for measuring electrochemical properties of a front surface of a test object in a liquid...... in the bottom surface and configured for passage of said liquid, such that liquid is able to pass onto the electrically contacted front surface. The holder may be used in an electrochemical cell....

  10. 78 FR 44957 - Agency Information Collection Activities: BioWatch Filter Holder Log, Filter Holder Log DHS Form...

    Science.gov (United States)

    2013-07-25

    ... record of the filter installed plus give a written chain-of-custody record tied to each collected filter... warfare agent. In addition, filter holder logs (chain-of-custody records) should be consistent nationwide... establishing the chain of custody for any filter samples used for criminal prosecution (chain of custody is the...

  11. Tomographic Heating Holder for In Situ TEM

    DEFF Research Database (Denmark)

    Gontard, Lionel C.; Dunin-Borkowski, Rafal E.; Fernández, Asunción

    2014-01-01

    A tomographic heating holder for transmission electron microscopy that can be used to study supported catalysts at temperatures of up to ~1,500°C is described. The specimen is placed in direct thermal contact with a tungsten filament that is oriented perpendicular to the axis of the holder withou...

  12. National Recordal System IK holder catalogue process

    CSIR Research Space (South Africa)

    Pretorius, R

    2012-10-01

    Full Text Available and IK holders against bio-piracy[2]. The IK audit trail will ensure that IK holders and communities are not locked out of any potential socio-economic benefits that may flow from their respective IK. One of the first activities when establishing a new...

  13. National Recordal System IK holder catalogue process

    CSIR Research Space (South Africa)

    Pretorius, R

    2011-11-01

    Full Text Available the communities and IK holders against bio-piracy[2]. The IK audit trail will ensure that IK holders and communities are not locked out of any potential socio- and economic benefi ts that may fl ow from their respective IK. One of the fi rst activities when...

  14. 7 CFR 930.60 - Equity holders.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Equity holders. 930.60 Section 930.60 Agriculture... Regulations § 930.60 Equity holders. (a) Inventory reserve ownership. The inventory reserve shall be the sole responsibility of the handlers who place products into the inventory reserve. A handler's equity in the primary...

  15. 19 CFR 10.7 - Substantial containers or holders.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Substantial containers or holders. 10.7 Section 10... Exported and Returned § 10.7 Substantial containers or holders. (a) Substantial containers or holders... domestic products exported and returned. When such containers or holders are imported not containing or...

  16. Diabetes management in Commercial Driver License holders.

    Science.gov (United States)

    Kerr, Jessica L; Frichtl, Kelsey D; Behnen, Erin M

    2015-04-01

    The purpose of this study is to evaluate diabetes management in Commercial Driver License (CDL) holders, how prescribing habits change when treating this patient population, and health care providers' knowledge of regulations concerning insulin use in CDL holders. A survey was posted on the American Association of Diabetes Educators (AADE) Communities of Interest websites and was open for 2 weeks. The anonymous survey collected demographic data and evaluated the perspectives of health care providers on diabetes management in CDL holders. Descriptive statistics were used to analyze the survey results. A total of 139 AADE members responded to the survey, and 22.2% were prescribing providers. Findings from the survey indicated an overall lack of knowledge by health care professionals regarding the current laws affecting diabetes management in CDL holders. Most participants emphasized the need for making decisions on CDL suspension on a case-by-case basis, and some expressed concern that current laws may not be appropriate. Additional diabetes education for health care providers who treat CDL holders is warranted as many health care providers were not familiar with current regulations and management strategies. © 2015 The Author(s).

  17. Zaria Universal Oxygenator Holder Phase I

    African Journals Online (AJOL)

    The conduct of cardiopulmonary bypass surgery requires the use of several equipment and devices like the oxygenator.[1,2]. The oxygenator comes in different makes depending on the manufacturer and each manufacturer customizes the carrier or. 'holder' of this device specific to their design [Figures 1 and 2]. Aim.

  18. Lexan Linear Shaped Charge Holder with Magnets and Backing Plate

    Science.gov (United States)

    Maples, Matthew W.; Dutton, Maureen L.; Hacker, Scott C.; Dean, Richard J.; Kidd, Nicholas; Long, Chris; Hicks, Robert C.

    2013-01-01

    A method was developed for cutting a fabric structural member in an inflatable module, without damaging the internal structure of the module, using linear shaped charge. Lexan and magnets are used in a charge holder to precisely position the linear shaped charge over the desired cut area. Two types of charge holders have been designed, each with its own backing plate. One holder cuts fabric straps in the vertical configuration, and the other charge holder cuts fabric straps in the horizontal configuration.

  19. GUARANTEEING ASYMPTOTIC ZERO INTERSAMPLING TRACKING ERROR VIA A DISCRETIZED REGULATOR AND EXPONENTIAL HOLDER FOR NONLINEAR SYSTEMS

    Directory of Open Access Journals (Sweden)

    B. Castillo-Toledo

    2003-09-01

    Full Text Available In this paper we present the design of a robust discretized controller based in the theory of regulation for nonlinear systems. In the general command tracking and disturbance rejection problem, it is known that a sample data controller using zero order holder may only guarantee asymptotic tracking at the sampling instances. We show that by means of a so-called exponential holder, we are able to guarantee asymptotic zero output tracking error, not only in the sampling instant, but also between these instant. Some considerations on the design of exponential holders are presented. The application in simulation to some typical nonlinear systems shows the good performance of the proposed scheme.

  20. Zaria Universal Oxygenator Holder phase I

    Directory of Open Access Journals (Sweden)

    Sunday Adoga Edaigbini

    2014-01-01

    Full Text Available Introduction: The conduct of cardiopulmonary bypass surgery requires the use of equipment and devices like the oxygenator. The oxygenator comes in different makes and each manufacturer customizes the carrier or ′holder′ of this device specific to their design. Aim: This paper presents an innovation designed to overcome the need to purchase a different holder for every oxygenator thereby cutting the cost. Materials and Methods: A sheet of iron measuring 1.9 cm (width × 0.1 cm (thickness was used to design the holder circular main frame. Another sheet measuring 2 cm (width × 0.6 cm (thickness × 24 cm (length was used to construct a V-shaped handle with the arms of the V attached to the main frame 7 cm apart. At the narrow base of the handle is a latch requiring two 13-gauge screws to attach the holder to the heart-lung machine. Within the circumference of the main frame are four T-shaped side arms which grip the oxygenator; located at 2, 5, 7 and 11 O′clock positions. The stem of the T consist of a 0.6 cm (thickness × 13 cm (length rod drilled through the main frame. The cross of the T consists of variable lengths of the same sheet as the mainframe attached to the stem by a screw mechanism. At the base of the T, is attached a circular handle (4 cm in diameter made of 0.4 cm iron rod. Result: An oxygenator holder which weighs 1.75 kg with a total length of 54 cm (the diameter of the mainframe is 30 cm. Its advantages include (i affordability, (ii materials are locally accessible, (iii versatility (iv reproducibility. The disadvantages include, (i it requires some time to fit, (ii caution is required in fitting the oxygenator to avoid breakage, (iii a spanner is required to lock the latch. Conclusion: The concept of a universal holder is pertinent, especially in resource poor environments to avoid purchasing a new holder whenever the usual oxygenator common to the centre is unavailable. This device is amenable to further modifications to

  1. 38 CFR 36.4341 - Death or insolvency of holder.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Death or insolvency of... Death or insolvency of holder. (a) Immediately upon the death of the holder and without the necessity of... applicable in the event of: (1) Insolvency of holder; (2) Initiation of any bankruptcy or reorganization, or...

  2. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  3. Rapid eye movement sleep in breath holders.

    Science.gov (United States)

    Kohyama, J; Hasegawa, T; Shimohira, M; Fukumizu, M; Iwakawa, Y

    2000-07-01

    One-night polysomnography was performed on seven subjects suffering from breath-holding spells, including one whose death was suggested to be a consequence of a breath-holding spell. The fatal case showed no rapid eye movements (REMs) during REM sleep, although he exhibited REMs during wakefulness. The average numbers of both REMs and bursts of REMs in REM sleep in the other six breath holders were significantly lower than those in age-matched controls. The breath holders showed no airway obstruction, desaturation, or sleep fragmentation. Since the rapid ocular activity in REM sleep is generated in the brain stem, we hypothesized that a functional brainstem disturbance is involved in the occurrence of breath-holding spells.

  4. Zaria Universal Oxygenator Holder Phase I

    African Journals Online (AJOL)

    A sheet of iron measuring 1.9 cm (width) × 0.1 cm (thickness) was used to design the holder circular main frame [Figure 3]. Another sheet measuring 2 cm (width) × 0.6 cm (thickness). × 24 cm (length) was used to construct a V‑shaped handle with the arms of the V attached to the main frame 7 cm apart. At the narrow base of ...

  5. Holder pasteurization affects S100B concentrations in human milk.

    Science.gov (United States)

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Li Volti, Giovanni; Galvano, Fabio; Visser, Gerard H A; Gazzolo, Diego

    2017-02-28

    Donor milk (DM) represents an important nutrition source for high-risk newborns. Holder pasteurization (HoP) is the most recommended procedure for DM treatment, providing a good compromise between microbiological safety and biological quality. HoP was previously shown to affect DM cytokines, growth factors and hormones levels, whilst no data concerning the possible effects of HoP on neurobiomarkers (NB) are available. Therefore, our study investigated whether the concentration in DM of a well-known NB involved in brain development/damage, namely S100B, changes due to HoP. We conducted a pretest-test study in 11 mothers, whose DM samples were sub-divided into two parts: the first was immediately frozen (-80 °C); the second was pasteurized with Holder method before freezing. S100B DM levels were measured using a commercially available immunoluminometric assay. S100B protein was detected in all milk samples. Results showed significant differences between groups (p milk as well as in term milk during maturation degree. Moreover, the results confirm the susceptibility of this neurotrophic factor to pasteurization stresses and the need to develop new storage techniques to preserve the biological quality of human milk.

  6. Ni-625 Superalloy Foam Processed by Powder Space-Holder Technique

    Science.gov (United States)

    Unver, Ismail; Gulsoy, H. Ozkan; Aydemir, Bulent

    2013-12-01

    In this work, porous Ni-625 superalloys were produced by use of a water soluble pore forming agent prior to sintering. Carbamide particles were used as the space-holder materials. After mixing and compaction, the space-holder particles were extracted using warm water leaching over a range of temperatures. The porous green parts were subsequently thermally debinding to remove the paraffin wax under a pure Argon atmosphere, and subsequently sintered at high vacuum. The effects of volume fraction of space-holder particles on density, porosity, and elastic modulus were investigated. Microstructures were captured using optical and scanning electron microscopy. Pore size was quantified using image analysis software integral to the scanning electron microscopy. In addition, compression tests were conducted on the sintered samples.

  7. Laser Holder Aids Centering of X-Ray Head

    Science.gov (United States)

    Bulthuis, D. V.; Kettering, D. D.

    1986-01-01

    Laser holder used when alining X-ray head makes procedure safer and more reliable. Laser holder assembly attached to X-ray head to enable head to be alined optically before X-ray exposure. When laser in operating position laser beam shines on spot later illuminated with X-rays. New holder grips laser securely, maintains alinement, does not interfere with head placement, and requires only one 110-V power cord.

  8. Ebola Virus and Marburg Virus in Human Milk Are Inactivated by Holder Pasteurization.

    Science.gov (United States)

    Hamilton Spence, Erin; Huff, Monica; Shattuck, Karen; Vickers, Amy; Yun, Nadezda; Paessler, Slobodan

    2017-05-01

    Potential donors of human milk are screened for Ebola virus (EBOV) using standard questions, but testing for EBOV and Marburg virus (MARV) is not part of routine serological testing performed by milk banks. Research aim: This study tested the hypothesis that EBOV would be inactivated in donor human milk (DHM) by standard pasteurization techniques (Holder) used in all North American nonprofit milk banks. Milk samples were obtained from a nonprofit milk bank. They were inoculated with EBOV (Zaire strain) and MARV (Angola strain) and processed by standard Holder pasteurization technique. Plaque assays for EBOV and MARV were performed to detect the presence of virus after pasteurization. Neither EBOV nor MARV was detectable by viral plaque assay in DHM or culture media samples, which were pasteurized by the Holder process. EBOV and MARV are safely inactivated in human milk by standard Holder pasteurization technique. Screening for EBOV or MARV beyond questionnaire and self-deferral is not needed to ensure safety of DHM for high-risk infants.

  9. 21 CFR 880.5680 - Pediatric position holder.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5680 Pediatric position holder. (a) Identification. A pediatric position holder is a device... administered. (b) Classification. Class I (general controls). The device is exempt from the good manufacturing...

  10. 21 CFR 892.1920 - Radiographic head holder.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1920 Radiographic head holder. (a) Identification. A radiographic head holder is a device intended to position the patient's head during a radiographic procedure. (b) Classification. Class I (general controls). The device is exempt from the premarket...

  11. Influence of bowl shaped substrate holder on growth of polymeric ...

    Indian Academy of Sciences (India)

    The input microwave power was about 300W. Earlier, under the same growth conditions, no deposition was achieved when flat molybdenum/steel substrate holders were used. In this study, two different designs of bowl shaped steel substrate holder at different bias have been experimented. Raman spectra confirm the DLC ...

  12. 14 CFR 21.165 - Responsibility of holder.

    Science.gov (United States)

    2010-01-01

    ... manual describing its quality system to the FAA for approval. The manual must be in the English language... Inspections and tests. Each applicant for or holder of a production certificate must allow the FAA to inspect... CERTIFICATION PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.165 Responsibility of holder. The...

  13. Influence of endodontic instrument-holder on sterilization efficacy. A pilot in-vitro study.

    Directory of Open Access Journals (Sweden)

    Angelo Carrizo

    2013-08-01

    Full Text Available Infection control is crucial in dentistry and various methods have been designed to assure its efficacy. However, little information exists regarding the influence it could have the instrument-holder of endodontic files. The aim of this research was to determine the influence of three instruments-holders on sterilization efficacy of endodontic files. Methods: A pilot in-vitro study. 60 endodontic files were contaminated by biomechanical preparation of extracted molars with periapical abscess, then processed according to the standard washing method. The endodontic files were divided into 3 groups (n=20 and assigned to 3 instrument-holders: Metallic box (MB, surgical gauze (SG and synthetic sponge (SS. Then, the files were packaged and sterilized by autoclaving (134°C/45min. Microbiological culture was performed in thioglycolate solution for each endodontic file (37ºC/5days. Results: The overall sterilization efficacy was 91.7%, 80% for MB, 100% for SS, and 95% for SG, with no statistically significant differences (p=0.06 between the groups. Conclusions: The lack of differences in the efficacy of sterilization may be due to the reduced sample; therefore, a full-size study is necessary to confirm this outcomes. The results of this study discourage the use of the MB as instrument-holder until a full-size study can confirm this data.

  14. Development of a versatile TEM specimen holder for the characterization of photocatalytic materials

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Langhammer, C.; Hansen, Thomas Willum

    2011-01-01

    Photocatalysts are of fundamental interest for sustainable energy research [1]. By means of transmission electron microscopy (TEM), it is possible to obtain insight into their structure, composition and reactivity. Such insight can then be used for their further optimization [2]. Here, we combine...... conventional TEM analysis on photocatalysts with several in situ TEM techniques including environmental TEM (ETEM), in situ photo activation and localized surface plasmon resonance (LSPR) spectroscopy [3-4]. These experiments are facilitated by the construction of a specimen holder capable of illuminating...... samples inside the TEM with a laser diode and an optical system to guide light onto the sample with maximum power transmission. The source can be changed and tuned between the visible and the UV range. The specimen holder is equipped with five electrical contacts that can be used to perform in situ...

  15. 38 CFR 36.4350 - Servicing procedures for holders.

    Science.gov (United States)

    2010-07-01

    ... vandalism and the elements. Thereafter, the holder shall schedule inspections at least monthly to prevent unnecessary deterioration due to vandalism, or neglect. With respect to any loan more than 60 calendar days...

  16. Zaria Universal Oxygenator Holder Phase I | Edaigbini | Nigerian ...

    African Journals Online (AJOL)

    Abstract. Introduction: The conduct of cardiopulmonary bypass surgery requires the use of equipment and devices like the oxygenator. The oxygenator comes in different makes and each manufacturer customizes the carrier or 'holder' of this device specific to their design. Aim: This paper presents an innovation designed to ...

  17. Small holder farmers coping strategies to household food insecurity ...

    African Journals Online (AJOL)

    This study has aimed at examining the small holder farmers' coping strategies to sustained household food insecurity and hunger in Southern Ethiopia (Sidama Zone). In order to collect the required input data, a comprehensive interview schedule was developed. The data were collected from 614 households who were ...

  18. 24 CFR 401.556 - Leasing units to voucher holders.

    Science.gov (United States)

    2010-04-01

    ... Development (Continued) OFFICE OF HOUSING AND OFFICE OF MULTIFAMILY HOUSING ASSISTANCE RESTRUCTURING, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT MULTIFAMILY HOUSING MORTGAGE AND HOUSING ASSISTANCE RESTRUCTURING... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Leasing units to voucher holders...

  19. 39 Small holder farmers coping strategies to household food ...

    African Journals Online (AJOL)

    `123456789jkl''''#

    Abstract. This study has aimed at examining the small holder farmers' coping strategies to sustained household food insecurity and hunger in Southern Ethiopia (Sidama Zone). In order to collect the required input data, a comprehensive interview schedule was developed. The data were collected from 614 households who ...

  20. Socio-economic characteristics of small-holder farmers influencing ...

    African Journals Online (AJOL)

    holder farmers influencing utilisation of micro-credit in the central agricultural zone of Cross River State. With the aid of two sets of structured questionnaires, data on socio-economic characteristics were collected from 240 food crop farmers in ...

  1. 39 Small holder farmers coping strategies to household food ...

    African Journals Online (AJOL)

    `123456789jkl''''#

    This study has aimed at examining the small holder farmers' coping strategies to sustained household food insecurity and hunger in Southern Ethiopia .... widely accepted tools developed by the Food and Nutrition Technical Assistance Project ..... Conservation Ecology, 5(2), 18. Bureau of Statistics and Population, BoSP.

  2. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  3. Choosing health: qualitative evidence from the experiences of personal health budget holders.

    Science.gov (United States)

    Davidson, Jacqueline; Baxter, Kate; Glendinning, Caroline; Irvine, Annie

    2013-10-01

    Personal health budgets were piloted in the English National Health Service between 2009 and 2012. Semi-structured interviews with a sub-sample of early budget holders aimed to explore their experiences of receiving and using a budget. Over 2000 people from 20 pilot sites were recruited to a multi-method evaluation of the personal health budget pilots. A sub-sample of 58 people was selected for qualitative interviews three months after the offer of a budget; 52 were re-interviewed six months later. The purposively selected sample reflected a range of health conditions, locality, age and gender. Personal health budgets were reported to have positive impacts on health, health care and relatives/family. Benefits often extended beyond the condition for which the budget had been awarded. However, interviewees rarely knew the level of their budget; some reported difficulty in agreeing acceptable uses for their budget; and delays could occur in procuring chosen services or equipment. Patients' experiences offer valuable insights for the roll-out of personal health budgets beyond the pilot phase. Flexibility in how budgets are used may allow maximum benefits to be derived. Clear information about what budgets can and cannot be used for, with suggestions offered, will be useful. People with newly diagnosed or recent sudden onset conditions may need more help to plan their support, but all budget holders are likely to benefit from regular contact with staff for reassurance and continued motivation.

  4. 12 CFR 611.1210 - Advance notices-commencement resolution and notice to equity holders.

    Science.gov (United States)

    2010-01-01

    ... notice to equity holders. 611.1210 Section 611.1210 Banks and Banking FARM CREDIT ADMINISTRATION FARM...—commencement resolution and notice to equity holders. (a) Adoption of commencement resolution. Your board of... advance notice to all equity holders stating you are taking steps to terminate System status. Immediately...

  5. 78 FR 9720 - Agency Information Collection Activities: Holders or Containers Which Enter the United States...

    Science.gov (United States)

    2013-02-11

    ... SECURITY U.S. Customs and Border Protection Agency Information Collection Activities: Holders or Containers... review and approval in accordance with the Paperwork Reduction Act: Holders or Containers which enter the... techniques or other forms of information. Title: Holders or Containers which Enter the United States Duty...

  6. 77 FR 69650 - Agency Information Collection Activities: Holders or Containers Which Enter the United States...

    Science.gov (United States)

    2012-11-20

    ... SECURITY U.S. Customs and Border Protection Agency Information Collection Activities: Holders or Containers... concerning the Holders or Containers which Enter the United States Duty Free. This request for comment is...: Title: Holders or Containers which Enter the United States Duty Free. OMB Number: 1651-0035. Form Number...

  7. Interest in nursing among academic degree holders in Israel: A cross-sectional quantitative study.

    Science.gov (United States)

    Ben Natan, Merav

    2016-03-01

    The shortage of nurses is a global problem. One strategy for producing more registered nurses worldwide and in Israel in particular is to offer graduate entry nursing programs for individuals with non-nursing academic degrees. In order to recruit academic degree holders into the nursing profession, it is important to identify factors that might attract them. The purpose of this study was to explore whether the perception of nurse characteristics by academic degree holders is associated with their interest in enrolling in a graduate entry nursing program or in recommending this program to a family member, and whether ethnic background, gender and interaction with a nurse have an effect on this interest. A cross-sectional quantitative study. The setting of the study was on the campus of Tel Aviv University. A convenience sample of 522 individuals with an academic education, men and women, aged 18-60 and equally distributed between Jewish and Arab Israelis, took part in the study. Participants completed a questionnaire based on the Porter Nursing Image Scale. A moderate positive correlation was found between perception of nurses and interest in nursing (r=0.32, pacademic education. Recruitment strategies should be tailored to each of this population's subgroups. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Evaluation of the maxillary premolar roots dissociation using radiographic holders with conventional and digital radiography

    Directory of Open Access Journals (Sweden)

    Marcia Regina Ramalho da Silva Bardauil

    2010-09-01

    Full Text Available This in vivo study evaluated the dissociation quality of maxillary premolar roots combining variations of vertical and horizontal angulations by using X-ray holders (Rinn -XCP, and made a comparison between two types of intraoral radiography systems - conventional film (Kodak Insight, Rochester, USA and digital radiography (Kodak RVG 6100, Kodak, Rochester, USA. The study sample was comprised of 20 patients with a total of 20 maxillary premolars that were radiographed, using the paralleling angle technique (GP, with a 20º variation of the horizontal angle (GM and 25º variation of the horizontal angle combined with 15º vertical angle (GMV. Each image was independently analyzed by two experienced examiners. These examiners assigned a score to the diagnostic capability of root dissociation and the measurement of the distance between the apexes. Statistical data was derived using the Wilcoxon Signed Rank test, Friedman and T test. The means of the measured distances between buccal and lingual root apexes were greater for the GMV, which ranged from 2.3 mm to 3.3 mm. A statistically significant difference was found between GM and GMV when compared to GP with p < 0.01. An established best diagnostic dissociation roots image was found in the GMV. These results support the use of the anterior X-ray holders which offer a better combined deviation (GMV to dissociate maxillary premolar roots in both radiography systems.

  9. Custom fit 3D-printed brain holders for comparison of histology with MRI in marmosets.

    Science.gov (United States)

    Guy, Joseph R; Sati, Pascal; Leibovitch, Emily; Jacobson, Steven; Silva, Afonso C; Reich, Daniel S

    2016-01-15

    MRI has the advantage of sampling large areas of tissue and locating areas of interest in 3D space in both living and ex vivo systems, whereas histology has the ability to examine thin slices of ex vivo tissue with high detail and specificity. Although both are valuable tools, it is currently difficult to make high-precision comparisons between MRI and histology due to large differences inherent to the techniques. A method combining the advantages would be an asset to understanding the pathological correlates of MRI. 3D-printed brain holders were used to maintain marmoset brains in the same orientation during acquisition of ex vivo MRI and pathologic cutting of the tissue. The results of maintaining this same orientation show that sub-millimeter, discrete neuropathological features in marmoset brain consistently share size, shape, and location between histology and ex vivo MRI, which facilitates comparison with serial imaging acquired in vivo. Existing methods use computational approaches sensitive to data input in order to warp histologic images to match large-scale features on MRI, but the new method requires no warping of images, due to a preregistration accomplished in the technique, and is insensitive to data formatting and artifacts in both MRI and histology. The simple method of using 3D-printed brain holders to match brain orientation during pathologic sectioning and MRI acquisition enables rapid and precise comparison of small features seen on MRI to their underlying histology. Published by Elsevier B.V.

  10. Unsupervised driving by learner licence holders: associated characteristics and crash risk.

    Science.gov (United States)

    Langley, John; Begg, Dorothy; Samaranayaka, Ari; Brookland, Rebecca; Weiss, Harold

    2013-11-01

    To determine: (a) the association between socio-demographic, and behavioural factors and compliance with supervised driving condition as a learner licensed driver, (b) whether unsupervised driving as a learner licence holder was associated with elevated crash risk while holding a learner licence. The study population was the New Zealand Drivers Study (NZDS) cohort, a prospective cohort study designed to explore the relationship between a comprehensive range of driving and traffic safety related factors and subsequent traffic crashes and convictions among newly licensed drivers. Thirty-one percent of the study sample was non-compliant at least once with the supervised driving condition. Many socio-demographic and behavioural risk factors were independently associated with unsupervised driving. The strength of the associations was greatest for those with relatively high levels of unsupervised driving (13+ trips). High distance driven showed the strongest relationship: RR 8.91 (95% CI 5.27-15.07). Unsupervised driving was associated with increased risk of crash: 1-12 trips: RR 1.84 (1.29-2.61), and 13+ trips: RR 2.71 (1.94-3.80). Given that a significant portion of learner licence holders report driving unsupervised and those that violate this condition the most are more likely to crash, evaluation of strategies designed at improving compliance with learner licence supervised driving condition should be a research priority. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Smart Farming: Including Rights Holders for Responsible Agricultural Innovation

    Directory of Open Access Journals (Sweden)

    Kelly Bronson

    2018-02-01

    Full Text Available This article draws on the literature of responsible innovation to suggest concrete processes for including rights holders in the “smart” agricultural revolution. It first draws upon historical agricultural research in Canada to highlight how productivist values drove seed innovations with particular consequences for the distribution of power in the food system. Next, the article uses document analysis to suggest that a similar value framework is motivating public investment in smart farming innovations. The article is of interest to smart farming’s decision makers (from farmers to governance actors and a broader audience – anyone interested in engendering equity through innovation-led societal transitions.

  12. INTERNATIONAL MOBILITY OF SPANISH MEN AND WOMEN DOCTORATE HOLDERS

    Directory of Open Access Journals (Sweden)

    Ana M. González Ramos

    2013-10-01

    Full Text Available Scientists are faced with many challenges along their international trajectory as they balance professional and family goals. Certain theoretical frameworks support the concept that career paths are shaped by social and institutional forces in science, whereas other theories point to family constraint factors as the reasoning behind scientists’ decisions to either go abroad or return home. Commonly, women scientists report many challenges when deciding to move internationally. In this paper we aim to exploit data from the Survey on Human Resources in Science and Technology, carried out by the Spanish Statistical Office in 2010, by analysing the life course of 4,123 Spanish doctorate holders. The results indicate there is a strong influence of institutional forces constituting a scientific culture which promotes rules and certain habits about how scientists should progress in their careers. Such forces lead to increasing rates of international mobility. At the same time, the data reveal that decisions about leaving and returning depend on the life course of the doctorate holder, and usually involve some family and personal considerations. Women have adopted a similar career track to men regarding international mobility, although women with children present low rates of high mobility and, by contrast, childless women present higher rates of high mobility than childless men.

  13. Usefulness of needle holder with a function of fine forceps for bypass surgery in both hands.

    Science.gov (United States)

    Horiuchi, Tetsuyoshi; Seguchi, Tatsuya; Ito, Kiyoshi; Hongo, Kazuhiro

    2015-01-01

    In bypass surgery, a single-handed needle holder is usually used with other handed fine forceps. Recently, a needle holder with the function of fine forceps has been developed. In this technical note, usefulness of newly developed needle holders in both hands is presented in bypass surgery. With this method, surgeons can make stitches and ties by both hands without exchanging instruments. This method is effective and may result in faster anastomotic procedure comparing with the traditional one.

  14. 21 CFR 872.1905 - Dental x-ray film holder.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental x-ray film holder. 872.1905 Section 872...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1905 Dental x-ray film holder. (a) Identification. A dental x-ray film holder is a device intended to position and to hold x-ray film inside the mouth...

  15. Territory holders and non-territory holders in Ayu fish coexist only in the population growth process due to hysteresis.

    Science.gov (United States)

    Katsumata, Yuki; Uehara, Takashi; Ito, Hiromu; Yoshimura, Jin; Tainaka, Kei-Ichi; Ichinose, Genki

    2017-12-01

    Ayu fish form feeding territories during a non-breeding (growing) season. When the density of the fish increases, phases gradually change. In the early growing season, all fish can hold territories at low density. Once all territory sites are occupied, newcomers become floaters. As the density further increases, territory holders have to spend much more time in defending their own territory and lose the time to feed on algae. Eventually, all fish give up their own territories and then form a school. In contrast, when the density decreases, territories are directly reformed from the school. In short, ayu fish exhibit a different transition, called hysteresis, where the two transitions occur widely-apart from each other. The dynamics of this intrinsic phenomena has not been demonstrated in previous studies. We develop a rate equation to describe the population dynamics within territorial competition. Our model successfully reproduces territorial hysteresis and indicates that territory holders and floaters can coexist only in the process of population growth. Moreover, we also find that the two critical densities of territorial hysteresis are conspicuously different from each other when the increase of the density of floaters sharply influences (step-function-like) the territories.

  16. Late-Term Visual Adequateness of Driver License Holders

    Directory of Open Access Journals (Sweden)

    Arzu Seyhan Karatepe

    2013-06-01

    Full Text Available Pur po se: To evaluate the late-term visual adequateness of driver license holders. Ma te ri al and Met hod: A total of 160 driving license holders with a mean age of 48.39±10.86 (range, 21-73 years who attended our outpatient clinic underwent routine ophthalmologic examination, and their driver license data were evaluated under their consent. Re sults: The spectacle need for 160 people who got their driving license with a mean of 19.46±10.07 (21-73 years ago was 26/160 (16.25% by the time they got their license, whereas 118/160 (73.75% - by the date we evaluated them. Six people (3.75% were not using spectacles although they had refractive errors that should be corrected to be able to drive by law, and 2 people (1.25% had driving license although they did not have enough visual acuity to get a driving license. The first ophthalmologic examination that these 160 cases had was a mean of 12.29±8.21 (1-25 years after they got their driving license. Dis cus si on: When compared with the time people first got their driving license, the rate of refractive errors that affected visual acuity was increased 5 fold in a mean of twenty years. In our country, the inspection of motor vehicles after the third year of their landing and then in every two years is obligatory. The periodic health evaluation of the drivers is only obligatory if there is a detected progressive eye disease by the time they got their driving license. As there is no obligation for periodic examination, people who were healthy when getting the driving license can drive life long, even if their ability to drive safely is impaired due to certain vision changes. We think that in order to decrease the amount of traffic accidents in our country, not only motor vehicles but also driving license holders should have obligatory periodic health evaluation. (Turk J Ophthalmol 2013; 43: 183-5

  17. The Effect of Holder Pasteurization on Activin A Levels in Human Milk.

    Science.gov (United States)

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Li Volti, Giovanni; Galvano, Fabio; Barbagallo, Ignazio; Visser, Gerard H A; Gazzolo, Diego

    2016-11-01

    There is evidence that mother's own milk is the best nutrient in terms of multiorgan protection and infection prevention. However, when maternal milk is scarce, the solution can be represented by donor milk (DM), which requires specific storage procedures such as Holder Pasteurization (HoP). HoP is not free from side effects since it is widely known that it causes qualitative/quantitative changes in milk composition, particularly in the protein content. Therefore, the aim of this study is to investigate the effects of HoP on Activin A, a neurobiomarker known to play an important role in the development and protection of the central nervous system. In 24 mothers who delivered preterm (n = 12) and term (n = 12) healthy newborns, we conducted a pretest/test study where the milk donors acted as their own controls. Each sample was divided into two parts: the first was frozen at -80°C (Group 1); the second was Holder-pasteurized before freezing at -80°C (Group 2). Activin A was quantified using an ELISA test. Activin A was detected in all samples. There were no significant differences (p > 0.05) between the two groups, also when the analysis was stratified for gestational age at delivery and milk maturation degree (p > 0.05, for both). The present findings on the absence of any side effects of HoP on the milk concentration of Activin A offer additional support to the efficacy of HoP in DM storage. Our data open up to further investigations on neurobiomarkers' assessment in human milk and their preanalytical stability according to storage procedures.

  18. 26 CFR 1.860C-1 - Taxation of holders of residual interests.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Taxation of holders of residual interests. 1.860C-1 Section 1.860C-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.860C-1 Taxation of holders...

  19. 42 CFR 60.53 - Notification to lender or holder of change in enrollment status.

    Science.gov (United States)

    2010-10-01

    ... SERVICES GRANTS HEALTH EDUCATION ASSISTANCE LOAN PROGRAM The School § 60.53 Notification to lender or holder of change in enrollment status. Each school must notify the holder of a HEAL loan of any change in... failure to enroll as scheduled for any academic period as a full-time student, the student's latest known...

  20. 30 CFR 14.1 - Purpose, effective date for approval holders.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Purpose, effective date for approval holders... TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS REQUIREMENTS FOR THE APPROVAL OF FLAME-RESISTANT CONVEYOR BELTS General Provisions § 14.1 Purpose, effective date for approval holders. This Part...

  1. 17 CFR 240.14a-3 - Information to be furnished to security holders.

    Science.gov (United States)

    2010-04-01

    ... report shall contain information relating to the registrant's industry segments, classes of similar... holders, proxy statement or Notice of Internet Availability of Proxy Materials, as described in § 240.14a... report to security holders, proxy statement or Notice of Internet Availability of Proxy Materials, as...

  2. 14 CFR Appendix O to Part 121 - Hazardous Materials Training Requirements For Certificate Holders

    Science.gov (United States)

    2010-01-01

    ... any shipper, including a will-not-carry certificate holder offering dangerous goods for transport..., DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION... responsibilities and training. If offering goods on another certificate holder's equipment, the person must be...

  3. 19 CFR 134.24 - Containers or holders not designed for or capable of reuse.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Containers or holders not designed for or capable of reuse. 134.24 Section 134.24 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF... § 134.24 Containers or holders not designed for or capable of reuse. (a) Containers ordinarily discarded...

  4. 19 CFR 134.23 - Containers or holders designed for or capable of reuse.

    Science.gov (United States)

    2010-04-01

    ... reuse. 134.23 Section 134.23 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND... Containers or holders designed for or capable of reuse. (a) Usual and ordinary reusable containers or holders... capable of reuse after the contents have been consumed, whether imported full or empty, must be...

  5. 14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.

    Science.gov (United States)

    2010-01-01

    ... of original type certification or later increase in capacity have: (1) A maximum type-certificated... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Holders of type certificates: Fuel tank... Tank Flammability § 26.33 Holders of type certificates: Fuel tank flammability. (a) Applicability. This...

  6. Finite element study on the integrity of tool holder with integrated internal cooling channel

    Science.gov (United States)

    Zakaria, M. S.; Nordin, Fahmi; Jamalludin, Mohd Riduan; Rosli, M. U.; Rahim, Wan Mohd Faizal Wan Abd; Ishak, Muhammad Ikman; Khor, C. Y.

    2017-09-01

    Decent research attempts have been initiated to investigate the possibility of avoiding the use of cutting fluid. The most promising solution for dry cutting seems to be use of internal cooling. A novel design is proposed by using concept of internal cooling by integrating cooling channel in tool holder structure. Therefore, a finite element simulation is conducted to elucidate effect of cutting load exerted on the tool holder during turning process of titanium alloy and aluminum. Obtain result revealed resultant stress and displacement of deflection are highly affected by diameter size of internal cooling path. Besides, maximum stresses generated based on specified cutting parameter do not exceeding Young Modulus value of tool holder's material. Based on the simulation result, the integrity of tool holder is intact as deflection of tool holder is very small hence this novel design of internal cooling is feasible.

  7. Multifunctional TEM-specimen holder equipped with a piezodriving probe and an electron irradiation port.

    Science.gov (United States)

    Shindo, Daisuke; Suzuki, Satoshi; Sato, Kuniaki; Akase, Zentaro; Murakami, Yasukazu; Yamazaki, Kazuya; Ikeda, Yuuta; Fukuda, Tomohisa

    2013-08-01

    The charging effect due to electron irradiation in an electron microscope has been studied so far with incident electrons. Here we report on a new specimen holder to control the charging effect by using electrons emitted from an irradiation port in the holder while maintaining a constant intensity of the incident electron beam. Details of the charging effect, such as electric field variation, are expected to be investigated by electron holography. The new specimen holder was developed by modifying a double-probe piezodriving specimen holder to introduce an electron irradiation port in one of its two arms. As a result, the new modified specimen holder consists of a piezodriving probe and an electron irradiation port, both of which can be controlled in three dimensions, using piezoelectric elements and micrometers. We demonstrate that variations in the charging effect for epoxy resin and surface contamination can be observed by electron holography.

  8. 77 FR 16082 - In the Matter of All Power Reactor Licensees and Holders of Construction Permits in Active Or...

    Science.gov (United States)

    2012-03-19

    ... upon demonstration by the Licensee or CP holder of good cause. V In accordance with 10 CFR 2.202, the... construction permit (CP) holders\\1\\ identified in Attachment 1 to this Order hold licenses issued by the U.S... Part 52, ``Licenses, Certifications, and Approvals for Nuclear Power Plants.'' \\1\\ CP holders, as used...

  9. The effect of simulated flash heating pasteurisation and Holder pasteurisation on human milk oligosaccharides.

    Science.gov (United States)

    Daniels, Brodie; Coutsoudis, Anna; Autran, Chloe; Amundson Mansen, Kimberly; Israel-Ballard, Kiersten; Bode, Lars

    2017-08-01

    Human milk oligosaccharides (HMOs) have important protective functions in human milk. A low-cost remote pasteurisation temperature-monitoring system has been designed using FoneAstra, a cell phone-based networked sensing system to monitor simulated flash heat pasteurisation. To compare the pasteurisation effect on HMOs of the FoneAstra FH method with the current Sterifeed Holder method used by human milk banks. Donor human milk samples (n = 48) were obtained from a human milk bank and pasteurised using the two pasteurisation methods. HMOs were purified from samples and labelled before separation using high-performance liquid chromatography. Concentrations of total HMOs, sialylated and fucosylated HMOs and individual HMOs using the two pasteurisation methods were compared using repeated-measures ANOVA. The study demonstrated no difference in total concentration of HMOs between the two pasteurisation methods and a small but significant increase in the total concentration of HMOs regardless of pasteurisation methods compared with controls (unpasteurised samples) (pmilk and therefore is a possible alternative for providing safely sterilised human milk for low- and middle-income countries.

  10. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders.

    Science.gov (United States)

    Özbilen, Sedat; Liebert, Daniela; Beck, Tilmann; Bram, Martin

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34-0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ(min) and σ(max) were varied systematically to estimate the fatigue limit (~4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders

    Energy Technology Data Exchange (ETDEWEB)

    Özbilen, Sedat [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); Gazi University, Faculty of Technology, Department of Metallurgical and Materials Engineering, Teknikokullar, Ankara (Turkey); Liebert, Daniela [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); Beck, Tilmann [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); University of Kaiserslautern, Lehrstuhl für Werkstoffkunde (WKK), D-67663 Kaiserslautern (Germany); Bram, Martin, E-mail: m.bram@fz-juelich.de [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany)

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34–0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ{sub min} and σ{sub max} were varied systematically to estimate the fatigue limit (~ 4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD. - Highlights: • Systematic variation of the oxygen content from 0.34 to 0.58 wt.%. • Systematic study of the relationship between fatigue limit and oxygen content. • Critical oxygen equivalent seems to be 0.35 wt.% to avoid embrittlement. • Identification of the failure modes by light microscopy, SEM and EBSD.

  12. Custom sample environments at the ALBA XPEEM

    Energy Technology Data Exchange (ETDEWEB)

    Foerster, Michael, E-mail: mfoerster@cells.es; Prat, Jordi; Massana, Valenti; Gonzalez, Nahikari; Fontsere, Abel; Molas, Bernat; Matilla, Oscar; Pellegrin, Eric; Aballe, Lucia

    2016-12-15

    A variety of custom-built sample holders offer users a wide range of non-standard measurements at the ALBA synchrotron PhotoEmission Electron Microscope (PEEM) experimental station. Some of the salient features are: an ultrahigh vacuum (UHV) suitcase compatible with many offline deposition and characterization systems, built-in electromagnets for uni- or biaxial in-plane (IP) and out-of-plane (OOP) fields, as well as the combination of magnetic fields with electric fields or current injection. Electronics providing a synchronized sinusoidal signal for sample excitation enable time-resolved measurements at the 500 MHz storage ring RF frequency. - Highlights: • Custom sample environment for XPEEM at ALBA. • Sample holders with electromagnets, in-plane dipole, in-plane quadruple and out-of-plane. • Sample holders with printed circuit boards for electric contacts including electromagnets. • UHV suitcase adapter. • Synchronized 500 MHz electrical excitation for time resolved measurements.

  13. A (S)TEM Gas Cell Holder with Localized Laser Heating for In Situ Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Mehraeen, Shareghe [Univ. of California, Davis, CA (United States). Dept. of Molecular and Cellular Biology; McKeown, Joseph T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Condensed Matter and Materials Division; Deshmukh, Pushkarraj V. [E.A. Fischione Instruments, Inc., Export, PA (United States); Evans, James E. [Univ. of California, Davis, CA (United States). Dept. of Molecular and Cellular Biology; Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Chemical and Materials Science Division; Abellan, Patricia [Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Chemical and Materials Science Division; Xu, Pinghong [Univ. of California, Davis, CA (United States). Dept. of Chemical Engineering and Materials Science; Reed, Bryan W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Condensed Matter and Materials Division; Taheri, Mitra L. [Drexel Univ., Philadelphia, PA (United States). Dept. of Materials Science & Engineering; Fischione, Paul E. [E.A. Fischione Instruments, Inc., Export, PA (United States); Browning, Nigel D. [Univ. of California, Davis, CA (United States). Dept. of Molecular and Cellular Biology; Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Chemical and Materials Science Division; Univ. of California, Davis, CA (United States). Dept. of Chemical Engineering and Materials Science

    2013-03-04

    We report that the advent of aberration correction for transmission electron microscopy has transformed atomic resolution imaging into a nearly routine technique for structural analysis. Now an emerging frontier in electron microscopy is the development of in situ capabilities to observe reactions at atomic resolution in real time and within realistic environments. Here we present a new in situ gas cell holder that is designed for compatibility with a wide variety of sample type (i.e., dimpled 3-mm discs, standard mesh grids, various types of focused ion beam lamellae attached to half grids). Its capabilities include localized heating and precise control of the gas pressure and composition while simultaneously allowing atomic resolution imaging at ambient pressure. The results show that 0.25-nm lattice fringes are directly visible for nanoparticles imaged at ambient pressure with gas path lengths up to 20 μm. Additionally, we quantitatively demonstrate that while the attainable contrast and resolution decrease with increasing pressure and gas path length, resolutions better than 0.2 nm should be accessible at ambient pressure with gas path lengths less than the 15 μm utilized for these experiments.

  14. A MEMS-based heating holder for the direct imaging of simultaneous in-situ heating and biasing experiments in scanning/transmission electron microscopes.

    Science.gov (United States)

    Mele, Luigi; Konings, Stan; Dona, Pleun; Evertz, Francis; Mitterbauer, Christoph; Faber, Pybe; Schampers, Ruud; Jinschek, Joerg R

    2016-04-01

    The introduction of scanning/transmission electron microscopes (S/TEM) with sub-Angstrom resolution as well as fast and sensitive detection solutions support direct observation of dynamic phenomena in-situ at the atomic scale. Thereby, in-situ specimen holders play a crucial role: accurate control of the applied in-situ stimulus on the nanostructure combined with the overall system stability to assure atomic resolution are paramount for a successful in-situ S/TEM experiment. For those reasons, MEMS-based TEM sample holders are becoming one of the preferred choices, also enabling a high precision in measurements of the in-situ parameter for more reproducible data. A newly developed MEMS-based microheater is presented in combination with the new NanoEx™-i/v TEM sample holder. The concept is built on a four-point probe temperature measurement approach allowing active, accurate local temperature control as well as calorimetry. In this paper, it is shown that it provides high temperature stability up to 1,300°C with a peak temperature of 1,500°C (also working accurately in gaseous environments), high temperature measurement accuracy (<4%) and uniform temperature distribution over the heated specimen area (<1%), enabling not only in-situ S/TEM imaging experiments, but also elemental mapping at elevated temperatures using energy-dispersive X-ray spectroscopy (EDS). Moreover, it has the unique capability to enable simultaneous heating and biasing experiments. © 2016 Wiley Periodicals, Inc.

  15. A land management history for central Queensland, Australia as determined from land-holder questionnaire and aerial photography.

    Science.gov (United States)

    Fensham, Roderick J; Fairfax, Russell J

    2003-08-01

    Features of the land management history over a 125,755 km(2) area of central Queensland, Australia were determined from a variety of sources. A random sample of 205 site locations provided the basis for determining trends in land use. Trends in vegetation clearing were determined using sequential aerial photography for the sample sites, revealing a steady rate averaging nearly 1% of the region per annum over 41 years. This measure of sustained clearing over a large region is higher than recently published clearing rates from South America. Land types have been selectively cleared with over 90% of the Acacia on clay land type having been cleared. A land-holder questionnaire pertaining to the random sites yielded a response rate of 71% and provided information on vegetation clearing, ploughing, tree killing (ring-barking or tree poisoning), and fire frequency, season and intensity. The land-holder responses were compared with independent data sources where possible and revealed no mis-information. However, land-holders may have been marginally less likely to respond if the sample area had been cleared, although this effect was not statistically significant. Ploughing and tree killing are variable depending on land type, but the former has affected about 40% of the Acacia on clay land type, effectively eliminating options for natural regrowth. The proportion of decade-site combinations that were reported as having no fires increased from 22% in the 1950s to an average of 42% for subsequent decades, although the reporting of more than one fire per decade has been relatively constant through the study period. The reporting of at least one fire per decade varies from 46% for the Acacia on sand land type to 77% for the Eucalypt on sand land type for decade-site combinations. Fires are more intense when associated with clearing than in uncleared vegetation, but the proportion of cool and hot fires is relatively constant between land types in uncleared vegetation. Nearly

  16. Development and testing of an integrated smart tool holder for four-component cutting force measurement

    Science.gov (United States)

    Xie, Zhengyou; Lu, Yong; Li, Jianguang

    2017-09-01

    Cutting force measurement is a significant requirement for monitoring and controlling the machining processes. Hence, various methods of measuring the cutting force have been proposed by many researchers. In this study, an innovative integrated smart tool holder system based on capacitive sensors is designed, constructed and tested, which is capable of measuring triaxial cutting force and a torque simultaneously in a wireless environment system. A standard commercial tool holder is modified to make itself be the force sensing element that has advantages of simple structure and easy machining. Deformable beams are created in the tool holder, and the tiny deformations of which used to calculate the four-component cutting force are detected by six high precision capacitive sensors. All the sensors and other electronics, like data acquisition and transmitting unit, and wireless power unit, are incorporated into the tool holder as a whole system. The device is intended to be used in a rotating spindle such as in milling and drilling processes. Eventually, the static and dynamic characteristics of the smart tool holder have been determined by a series of tests. Cutting tests have also been carried out and the results show it is stable and practical to measure the cutting force in milling and drilling processes.

  17. Brittle Fracture Behaviors of Large Die Holders Used in Hot Die Forging

    Directory of Open Access Journals (Sweden)

    Weifang Zhang

    2017-05-01

    Full Text Available Brittle fracture of large forging equipment usually leads to catastrophic consequences. To avoid this kind of accident, the brittle fracture behaviors of a large die holder were studied by simulating the practical application. The die holder is used on the large die forging press, and it is made of 55NiCrMoV7 hot-work tool steel. Detailed investigations including mechanical properties analysis, metallographic observation, fractography, transmission electron microscope (TEM analysis and selected area electron diffraction (SAED were conducted. The results reveal that the material generated a large quantity of large size polyhedral M23C6 (M: Fe and Cr mainly and elongated M3C (M: Fe mainly carbides along the martensitic lath boundaries when the die holder was recurrently tempered and water-cooled at 250 °C during the service. The large size carbides lead to the material embrittlement and impact toughness degradation, and further resulted in the brittle fracture of the die holder. Therefore, the operation specification must be emphasized to avoid the die holder being cooled by using water, which is aimed at accelerating the cooling.

  18. [Research on distribution of patents' holders for Chinese herbal compounds in treating cardiovascular and cerebrovascular based on cluster analysis].

    Science.gov (United States)

    YANG, Xu-Jie; XIAO, Shi-Ying

    2015-09-01

    To discuss the distribution of patents' holders for Chinese herbal compounds in treating cardiovascular and cerebrovascular, the patents' holders for Chinese herbal compounds in treating cardiovascular and cerebrovascular were cluster analyzed by means of simple statistics and cluster analysis. Clustering variables were composed of patent applications, patent maintained number, related papers' quantity, etc. Chinese herbal compound patents' holders were divided into four categories according to their different scientific research and patent strength. It is the magic weapon for Chinese herbal compound patents' holders that have scientific research patents' transforming and make coordination of patent protection and scientific innovation.

  19. Position of document holder and work related risk factors for neck pain among computer users: a narrative review.

    Science.gov (United States)

    Ambusam, S; Baharudin, O; Roslizawati, N; Leonard, J

    2015-01-01

    Document holder is used as a remedy to address occupational neck pain among computer users. An understanding on the effects of the document holder along with other work related risk factors while working in computer workstation requires attention. A comprehensive knowledge on the optimal location of the document holder in computer use and associated work related factors that may contribute to neck pain reviewed in this article. A literature search has been conducted over the past 14 years based on the published articles from January 1990 to January 2014 in both Science Direct and PubMed databases. Medical Subject Headings (MeSH) keywords for search were neck muscle OR head posture OR muscle tension' OR muscle activity OR work related disorders OR neck pain AND/OR document location OR document holder OR source document OR copy screen holder.Document holder placed lateral to the screen was most preferred to reduce neck discomfort among occupational typists. Document without a holder was placed flat on the surface is least preferred. The head posture and muscle activity increases when the document is placed flat on the surface compared to when placed on the document holder. Work related factors such as static posture, repetitive movement, prolong sitting and awkward positions were the risk factors for chronic neck pain. This review highlights the optimal location for document holder for computer users to reduce neck pain. Together, the importance of work related risk factors for to neck pain on occupational typist is emphasized for the clinical management.

  20. Improvement of effective solid angle using virtual-pivot holder and large EDS detector.

    Science.gov (United States)

    Koshiya, Shogo; Kimoto, Koji

    2017-02-01

    This paper describes the effective solid angle improvement achieved using a large-area silicon drift detector together with a virtual-pivot double-tilt specimen holder. The virtual-pivot mechanism enables various designs of specimen-retaining and can reduce the shadowing effect. Energy-dispersive X-ray spectra were measured and converted into effective solid angles using different types of specimen holders and specimens. The investigated shadowing-free mechanical system yielded effective solid angles approaching the nominal solid angle of 0.464sr. In addition, we have demonstrated the availability of the plastic (polyetheretherketone) specimen holder for low system noise. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Further improvement of an intraocular lens holder for more physiological measurements within a mechanical eye model

    Science.gov (United States)

    Reutterer, Bernd; Traxler, Lukas; Bayer, Natascha; Drauschke, Andreas

    2017-04-01

    To evaluate the performance of intraocular lenses to treat cataract, an optomechanical eye model was developed. One of the most crucial components is the IOL holder, which should guarantee a physiological representation of the capsular bag and a stable position during measurement sequences. Individual holders are required due to the fact that every IOL has different geometric parameters. A method which allows obtaining the correct dimensions for the holder of a special IOL was developed and tested, by verifying the position of the IOL before and after a measurement sequence. Results of telecentric measurements and MTF measurements show that the IOL position does not change during the displacement sequence induced by the stepper motors of the eye model.

  2. GENDER DIFFERENTIALS IN LABOUR PRODUCTIVITY AMONG SMALL-HOLDER CASSAVA FARMERS IN IDEATO LOCAL GOVERNMENT AREA OF IMO STATE, NIGERIA

    Directory of Open Access Journals (Sweden)

    Benjamin Chukwuemeka Okoye

    2011-12-01

    Full Text Available This study examined gender differentials in labour productivity among small-holder cassava (Manihot esculenta Crantz farmers in Ideato Local Government Area of Imo State, Nigeria in 2008. The study data was collected through a multi-stage random sampling technique from 120 cassava farmers, consisting of 60 males and 60 females. For the male farmers, the coefficients for household size and credit were negatively related to labour productivity and significant at 10.0% level of probability. For the female farmers, the coefficient for farm size was negative, while access to credit was positive; both were significant at 1.0% level of probability. The coefficients for education and age were negative and significant at 5.0% level of probability for all the farmers. The results call for policies aimed at land reforms by making more lands and easy accessibility tocredit available to women younger and more agile for increased labour productivity.

  3. Ecological Diversity of Soil Fauna as Ecosystem Engineers in Small-Holder Cocoa Plantation in South Konawe

    Directory of Open Access Journals (Sweden)

    Laode Muhammad Harjoni Kilowasid

    2012-05-01

    Full Text Available Taxa diversity within soil fauna functional groups can affected ecosystem functioning such as ecosystem engineers,which influence decomposition and nutrient cycling. The objective of this study is to describe ecological diversityvariation within soil fauna as ecosystem engineers in soil ecosystem of cocoa (Theobroma cacao L. plantation.Sampling was conducted during one year period from five different ages of plantation. Soil fauna removed from soilcore using hand sorting methods. A total of 39 genera of soil fauna as ecosystem engineers were found during thesestudies. Thirty five genera belong to the group of Formicidae (ants, three genera of Isoptera (termites, and onegenera of Oligochaeta (earthworms. Ecological diversity variation within ecosystem engineers was detected withSimpson indices for dominance and evenness. The highest diversity of ecosystem engineers was in the young ageof plantation. This study reinforces the importance biotic interaction which contributed to the distribution andabundance within soil fauna community as ecosystem engineers in small-holder cocoa plantation.

  4. Powder Handling Device for X-ray Diffraction Analysis with Minimal Sample Preparation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This project consists of developing a Vibrating Sample Holder (VSH) for planetary X-Ray Diffraction (XRD) instruments. The principle of this novel sample handling...

  5. Reverse H\\"older Property for strong weights and general measures

    OpenAIRE

    Luque, Teresa; Pérez, Carlos; Rela, Ezequiel

    2015-01-01

    We present dimension-free reverse H\\"older inequalities for strong $A^*_p$ weights, $1\\le p < \\infty$. We also provide a proof for the full range of local integrability of $A_1^*$ weights. The common ingredient is a multidimensional version of Riesz's "rising sun" lemma. Our results are valid for any nonnegative Radon measure with no atoms. For $p=\\infty$, we also provide a reverse H\\"older inequality for certain product measures. As a corollary we derive mixed $A_p^*-A_\\infty^*$ weighted est...

  6. Wild pollinators enhance oilseed rape yield in small-holder farming systems in China.

    Science.gov (United States)

    Zou, Yi; Xiao, Haijun; Bianchi, Felix J J A; Jauker, Frank; Luo, Shudong; van der Werf, Wopke

    2017-02-21

    Insect pollinators play an important role in crop pollination, but the relative contribution of wild pollinators and honey bees to pollination is currently under debate. There is virtually no information available on the strength of pollination services and the identity of pollination service providers from Asian smallholder farming systems, where fields are small, and variation among fields is high. We established 18 winter oilseed rape (Brassica napus L.) fields along a large geographical gradient in Jiangxi province in China. In each field, oilseed rape plants were grown in closed cages that excluded pollinators and open cages that allowed pollinator access. The pollinator community was sampled by pan traps for the entire oilseed rape blooming period. Oilseed rape plants from which insect pollinators were excluded had on average 38% lower seed set, 17% lower fruit set and 12% lower yield per plant, but the seeds were 17% heavier, and the caged plants had 28% more flowers and 18% higher aboveground vegetative biomass than plants with pollinator access. Oilseed rape plants thus compensate for pollination deficit by producing heavier seeds and more flowers. Regression analysis indicated that local abundance and diversity of wild pollinators were positively associated with seed set and yield/straw ratio, while honey bee abundance was not related to yield parameters. Wild pollinator abundance and diversity contribute to oilseed rape yield by enhancing plant resource allocation to seeds rather than to above-ground biomass. This study highlights the importance of the conservation of wild pollinators to support oilseed rape production in small-holder farming systems in China.

  7. Comparison of two film holders for periapical radiography performed by dental students.

    Science.gov (United States)

    Choksi, S K; Rao, M S

    1996-01-01

    A clinical study was done at Howard University, College of Dentistry, to compare the difference in the incidence of radiographic technique faults between two similar intraoral film-holding, beam-aligning, devices in a series of 1,248 radiographs. The primary difference between a conventional Extension Cone Paralleling (XCP-I) film holder and a modified, all-metal, Extension Cone Paralleling (XCP-II) film holder is the incorporation of a collimated rectangular x-ray-beam-restricting plate. This latter film holder possessed an indicator rod attached to the bite block and a metal shield to reduce primary and back-scattered radiation behind the film. In the oral diagnosis clinic, 78 dentulous patients were randomly selected and randomly divided into two groups of 39 patients. One of the two film holders was used separately for the two groups of patients, and a full mouth series of 16 periapical radiographs were made for each patient. The difference in the occurrence of total errors between the two instruments was not statistically significant. However, the conventional instrument was associated with significantly more errors in improper film positioning, while the modified device had significantly more errors in cone cutting (p < 0.01).

  8. 30 CFR 250.1010 - General requirements for pipeline right-of-way holders.

    Science.gov (United States)

    2010-07-01

    ... INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Pipelines and Pipeline... holder shall comply with applicable laws and regulations and the terms of the grant. (b) The granting of...-way oil or gas pipeline shall transport or purchase oil or natural gas produced from submerged lands...

  9. 76 FR 5296 - Safety Management System for Part 121 Certificate Holders; Extension of Comment Period

    Science.gov (United States)

    2011-01-31

    ... and provide meaningful comment to Notice No. 10-15. The Airline Safety and Federal Aviation Extension... Federal Aviation Administration 14 CFR Parts 5 and 119 RIN 2120-AJ86 Safety Management System for Part 121... require each certificate holder operating under 14 CFR part 121 to develop and implement a safety...

  10. Assessing the authority of political office-holders : The leadership capital index

    NARCIS (Netherlands)

    Bennister, Mark; t Hart, Paul|info:eu-repo/dai/nl/072685387; Worthy, Benjamin

    2015-01-01

    This article argues that the extent to which political office-holders can effectively attain and wield authority is a function of the stock of ‘leadership capital’. Drawing on the concept of political capital, the article defines leadership capital as aggregate authority composed of three

  11. In vitro efficacy of extracts from plants used by small-holder farmers ...

    African Journals Online (AJOL)

    Background: Bovine dermatophilosis, an important skin disease of cattle caused by Dermatophilus congolensis, negatively impacts the livelihoods of small-holder farmers in Zimbabwe. This impact is through, morbidity, loss of draught animal power, costs incurred to manage the disease, losses associated with devalued ...

  12. Evaluation of a cigarette holder for use in analytical smoking machines

    NARCIS (Netherlands)

    Hissink, M.; Bosman, R.

    1987-01-01

    A cigarette holder that simulates the lips of a human smoker has been tested for use in measurements of yields of tar, nicotine, and carbon monoxide. In this study, we tested five different brands of cigarettes that ranged in tar yield from 1 to 15 mg per cigarette. The dependence of the yields and

  13. 12 CFR 611.1215 - Communications with the public and equity holders.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Communications with the public and equity... ORGANIZATION Termination of System Institution Status § 611.1215 Communications with the public and equity... institution may communicate with equity holders and the public regarding the proposed termination, as long as...

  14. 19 CFR 134.22 - General rules for marking of containers or holders.

    Science.gov (United States)

    2010-04-01

    ... required for any good of a NAFTA country which is a usual container. (c) Containers or holders bearing a U... packing, storage and transportation materials. (2) A good of a NAFTA country which is a usual container. A good of a NAFTA country which is a usual container, whether or not disposable and whether or not...

  15. impact of climate change on small-holder farming: a case of eastern ...

    African Journals Online (AJOL)

    Prof. Adipala Ekwamu

    IMPACT OF CLIMATE CHANGE ON SMALL-HOLDER FARMING: A CASE OF. EASTERN TIGRAY, NORTHERN ETHIOPIA. KASSA TEKA1, 2, A. VAN ROMPAEY2, J. POESEN2, YEMANE WELDAY1 and J. DECKERS2. 1Department of Land Resources Management and Environmental Protection, Mekelle University,.

  16. A holder assembly for cooperating with an environmental cell and an electron microscope

    NARCIS (Netherlands)

    Zandbergen, H.W.; Pleun, D.; Van Veen, G.N.A.

    2013-01-01

    The invention relates to a holder assembly for cooperating with an environmental cell ( 101 ) and an electron microscope, the environmental cell showing a fluid inlet (103), the electron microscope showing a vacuum wall (110) for separating an evacuable part of the electron microscope from the

  17. Impact of climate change on small-holder farming: A case of eastern ...

    African Journals Online (AJOL)

    Impact of climate change on small-holder farming: A case of eastern Tigray, northern Ethiopia. K Terra, A Van Rompaey, J Poesen, Y Welday, J Deckers. Abstract. Although there are well-established concerns about climate change effects in northern Ethiopia, there is little quantitative information concerning how serious ...

  18. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    Energy Technology Data Exchange (ETDEWEB)

    Walker, B. J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, D. T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-06-06

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  19. Landscape effects on pollinator communities and pollination services in small-holder agroecosystems

    NARCIS (Netherlands)

    Zou, Yi; Bianchi, Felix J.J.A.; Jauker, Frank; Xiao, Haijun; Chen, Junhui; Cresswell, James; Luo, Shudong; Huang, Jikun; Deng, Xiangzheng; Hou, Lingling; Werf, van der Wopke

    2017-01-01

    Pollination by insects is key for the productivity of many fruit and non-graminous seed crops, but little is known about the response of pollinators to landscapes dominated by small-holder agriculture. Here we assess the relationships between landscape context, pollinator communities (density and

  20. 27 CFR 70.145 - Purchasers, holders of security interests, mechanic's lienors, and judgment lien creditors.

    Science.gov (United States)

    2010-04-01

    ... security interests, mechanic's lienors, and judgment lien creditors. 70.145 Section 70.145 Alcohol, Tobacco... Lien for Taxes § 70.145 Purchasers, holders of security interests, mechanic's lienors, and judgment... in § 70.143(a) of this part), mechanic's lienor (as defined in § 70.143(b) of this part), or judgment...

  1. 14 CFR 26.43 - Holders of and applicants for type certificates-Repairs.

    Science.gov (United States)

    2010-01-01

    ... issued after January 1, 1958, that as a result of original type certification or later increase in... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Holders of and applicants for type... type certificates—Repairs. (a) Applicability. Except as specified in paragraph (g) of this section...

  2. Surgical robotics. Evaluation of the Computer Motion AESOP 3000 robotic endoscope holder.

    Science.gov (United States)

    2002-07-01

    The use of robots to manipulate surgical instruments inside the patient has already moved from the world of fiction to fact. While the widespread use of full-function surgical robots is still many years away, less sophisticated robots that perform very specific surgical functions are already at a stage where the typical hospital can consider their use. Currently, the most affordable and commonly used type of "surgical-assist" robot is the robotic endoscope holder, which is used to hold and position rigid endoscopes during minimally invasive surgery. In this study, we introduce readers to the topic of surgical robotics, focusing specifically on robotic endoscope holders. The study includes a Technology Management Guide, in which we discuss who should and who shouldn't consider implementing such robots, and it includes our evaluation protocol and findings for one such robot, the Computer Motion AESOP 3000. We judged the evaluated system based on its performance relative to the human scope holders it is designed to replace, as well as its safety and ease of use. While we found the AESOP 3000 to be an acceptable, and sometimes preferred, alternative to the use of a human scope holder, we caution that many healthcare facilities won't see sufficient clinical benefit to warrant its purchase at this time.

  3. 17 CFR 240.14d-4 - Dissemination of tender offers to security holders.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Dissemination of tender offers to security holders. 240.14d-4 Section 240.14d-4 Commodity and Securities Exchanges SECURITIES AND... Regulations Under the Securities Exchange Act of 1934 Regulation 14d § 240.14d-4 Dissemination of tender...

  4. Highly identified power-holders feel responsible: The interplay between social identification and social power within groups.

    Science.gov (United States)

    Scholl, Annika; Sassenberg, Kai; Ellemers, Naomi; Scheepers, Daan; de Wit, Frank

    2018-01-01

    Power relations affect dynamics within groups. Power-holders' decisions not only determine their personal outcomes, but also the outcomes of others in the group that they control. Yet, power-holders often tend to overlook this responsibility to take care of collective interests. The present research investigated how social identification - with the group to which both the powerful and the powerless belong - alters perceived responsibility among power-holders (and the powerless). Combining research on social power and social identity, we argue that power-holders perceive more responsibility than the powerless when strongly (rather than when weakly) identifying with the group. A study among leaders and an experiment supported this, highlighting that although power-holders are often primarily concerned about personal outcomes, they do feel responsible for considering others' interests when these others are included in the (social) self. © 2017 The British Psychological Society.

  5. Evaluation of Different Holder Devices for Freeze-Drying in Dual-Chamber Cartridges With a Focus on Energy Transfer.

    Science.gov (United States)

    Korpus, Christoph; Friess, Wolfgang

    2017-04-01

    For freeze-drying in dual-chamber cartridges, a holder device to enable handling and safe positioning in the freeze-dryer is necessary. The aim of this study was to analyze 4 different types of holder devices and to define the best system based on energy transfer. The main criteria were drying homogeneity, ability to minimize the influence of atypical radiation on product temperatures, and heat transfer effectiveness. The shell holder reduced the influence of atypical radiation by almost 60% compared to a block system and yielded the most homogenous sublimation rates. Besides the most efficient heat transfer with values of 1.58E-4 ± 2.06E-6 cal/(s*cm2*K) at 60 mTorr to 3.63E-4 ± 1.85E-5 cal/(s*cm2*K) at 200 mTorr for Ktot, reaction times to shelf temperature changes were up to 4 times shorter compared to the other holder systems and even faster than for vials. The flexible holder provided a comparable shielding against atypical radiation as the shell but introduced a third barrier against energy transfer. Block and guardrail holder were the least efficient system tested. Hence, the shell holder provided the best radiation shielding, enhanced the transferability of the results to a larger scale, and improved the homogeneity between the dual-chamber cartridges. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  6. 17 CFR 240.14a-7 - Obligations of registrants to provide a list of, or mail soliciting material to, security holders.

    Science.gov (United States)

    2010-04-01

    ... beneficial holders, separated by type of holder and class, owning securities in the same class or classes as... Internet Availability of Proxy Materials (as described in § 240.14a-16), furnished by the security holder... single copy of the proxy statement or Notice of Internet Availability of Proxy Materials furnished by the...

  7. Fingerprint verification for smart-card holders based on an optical image encryption scheme

    Science.gov (United States)

    Suzuki, Hiroyuki; Yamaya, Taiga; Obi, Takashi; Yamaguchi, Masahiro; Ohyama, Nagaaki

    2003-11-01

    Fingerprint verification for smart card holders is one of the methods which are able to identify smart card holders with a high level of security. However, an ingenious implementation is needed to execute it in the embedded processor quickly and safely, because of its computational burden and the limitation of the smart card performance. For this purpose, we propose a hybrid method which is a combination of personal identification number (PIN) verification with a smart card and an optical fingerprint verification method. The result of a preliminary computer simulation to evaluate the proposed system shows that false acceptance rate is completely zero, though false rejection rate is a little inferior to the conventional figerprint verification system.

  8. Experimental verification of a deep drawing tool system for adaptive blank holder pressure distribution

    DEFF Research Database (Denmark)

    Tommerup, Søren; Endelt, Benny Ørtoft

    2012-01-01

    which can be integrated into existing stacked deep drawing tools without need for modification of the press. A working system is presented consisting of a controller, designated volume displacement cavity pressure supply units and a shimming plate. It is applied to the deep drawing of a rectangular......In deep drawing, the strain path in the blank during the forming process can be significantly affected by application of temporal and spatial variation of the blank holder force. In this study, an active tool system capable of controlling the distribution of the blank holder force is presented...... to the conventional shimming method using paper or metal shims between the tool plates. The tool system’s ability to influence the material flow is investigated by performing a series of deep drawing experiments. Eight different cavity pressure schemes are applied during the punch stroke and the scheme’s effects...

  9. Removing Entry Barriers of Small-holder Organic Farming in Korea

    OpenAIRE

    Suh, Chong Hyuk

    2014-01-01

    There have been many research references which have mentioned entry barriers in organic farming. According to previous studies in Korea, it is difficult for majority of small-holders to convert their conventional farming into organic farming due to difficulty in pest and weed control, compost making, marketing organic produces and lower yield and income during the initial 3-4 years. In other words, various types of entry barriers exist when starting organic farming. There is lack of confidenc...

  10. An MR/MRI compatible core holder with the RF probe immersed in the confining fluid

    Science.gov (United States)

    Shakerian, M.; Balcom, B. J.

    2018-01-01

    An open frame RF probe for high pressure and high temperature MR/MRI measurements was designed, fabricated, and tested. The open frame RF probe was installed inside an MR/MRI compatible metallic core holder, withstanding a maximum pressure and temperature of 5000 psi and 80 °C. The open frame RF probe was tunable for both 1H and 19F resonance frequencies with a 0.2 T static magnetic field. The open frame structure was based on simple pillars of PEEK polymer upon which the RF probe was wound. The RF probe was immersed in the high pressure confining fluid during operation. The open frame structure simplified fabrication of the RF probe and significantly reduced the amount of polymeric materials in the core holder. This minimized the MR background signal detected. Phase encoding MRI methods were employed to map the spin density of a sulfur hexafluoride gas saturating a Berea core plug in the core holder. The SF6 was imaged as a high pressure gas and as a supercritical fluid.

  11. Development and testing of an integrated rotating dynamometer on tool holder for milling process

    Science.gov (United States)

    Rizal, Muhammad; Ghani, Jaharah A.; Nuawi, Mohd Zaki; Che Haron, Che Hassan

    2015-02-01

    The cutting force provides significant information to help understand the machining process, optimization, tool condition monitoring, tool design and others. Hence, various methods of measuring the cutting force have been proposed by many researchers. In this work, an innovative integrated rotating dynamometer and tool holder is designed, constructed and tested that can fulfil the requirement to measure the cutting force in a wireless environment system. The device consists of a strain gauge based sensor that is mounted on a newly designed force sensing element which is then placed in the rotating tool holder. The force sensing element is designed in the form of a symmetrical cross beam type with four arms, shaped as a rectangular parallelepiped. This device is intended to be used in a rotating spindle such as in milling and drilling processes. A conditioning system and an inductive telemetry transmitter unit are incorporated into a modified tool holder in order to collect and transmit the cutting force signal to the data acquisition system. The rotating dynamometer has been subjected to a series of tests to determine its static and dynamic characteristics. Thus, it is tested experimentally by conducting cutting tests up to cutting speed 550 m/min with a single-tool insert. The results show it is suitable and reliable to measure the cutting force in milling processes.

  12. An MR/MRI compatible core holder with the RF probe immersed in the confining fluid.

    Science.gov (United States)

    Shakerian, M; Balcom, B J

    2018-01-01

    An open frame RF probe for high pressure and high temperature MR/MRI measurements was designed, fabricated, and tested. The open frame RF probe was installed inside an MR/MRI compatible metallic core holder, withstanding a maximum pressure and temperature of 5000 psi and 80 °C. The open frame RF probe was tunable for both 1H and 19F resonance frequencies with a 0.2 T static magnetic field. The open frame structure was based on simple pillars of PEEK polymer upon which the RF probe was wound. The RF probe was immersed in the high pressure confining fluid during operation. The open frame structure simplified fabrication of the RF probe and significantly reduced the amount of polymeric materials in the core holder. This minimized the MR background signal detected. Phase encoding MRI methods were employed to map the spin density of a sulfur hexafluoride gas saturating a Berea core plug in the core holder. The SF6 was imaged as a high pressure gas and as a supercritical fluid. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Modelling and Simulation of a New Variable Stiffness Holder for Milling of Flexible Details

    Directory of Open Access Journals (Sweden)

    Kaliński Krzysztof J.

    2017-04-01

    Full Text Available Modern industry expectations in terms of milling operations often demand the milling of the flexible details by using slender ball-end tools. This is a difficult task because of possible vibration occurrence. Due to existence of certain conditions (small depths of cutting, regeneration phenomena, cutting process may become unstable and self-excited chatter vibration may appear. Frequency of the chatter vibration is close to dominant natural frequency of the workpiece or the tool. One of the methods of chatter vibration avoidance is matching the spindle speed to the optimum phase shift between subsequent cutting edges passes (i.e. the Liao-Young condition. However, the set of optimum spindle speeds from the point of view of vibration reduction may be not optimum one from other points of view. For example milling efficiency or machine tool capabilities cannot be assured. This article presents the idea of a workpiece holder with adjustable stiffness and discusses a new variant of its realization. In the holder, milling process is performed at constant spindle speed and feed speed. In order to avoid vibration the holder stiffness is modified. Stiffness changes modify natural frequencies of the workpiece and thus it is possible to modify dynamic properties of the workpiece in such a way that arbitrary chosen, constant spindle speed will be optimum, due to the Liao-Young condition performance. Calculation of the optimum stiffness is performed before milling, based on the workpieces modal identification results and the finite element model simulations.

  14. New tool holder design for cryogenic machining of Ti6Al4V

    Science.gov (United States)

    Bellin, Marco; Sartori, Stefano; Ghiotti, Andrea; Bruschi, Stefania

    2017-10-01

    The renewed demand of increasing the machinability of the Ti6Al4V titanium alloy to produce biomedical and aerospace parts working at high temperature has recently led to the application of low-temperature coolants instead of conventional cutting fluids to increase both the tool life and the machined surface integrity. In particular, the liquid nitrogen directed to the tool rake face has shown a great capability of reducing the temperature at the chip-tool interface, as well as the chemical interaction between the tool coating and the titanium to be machined, therefore limiting the tool crater wear, and improving, at the same time, the chip breakability. Furthermore, the nitrogen is a safe, non-harmful, non-corrosive, odorless, recyclable, non-polluting and abundant gas, characteristics that further qualify it as an environmental friendly coolant to be applied to machining processes. However, the behavior of the system composed by the tool and the tool holder, exposed to the cryogenics temperatures may represent a critical issue in order to obtain components within the required geometrical tolerances. On this basis, the paper aims at presenting the design of an innovative tool holder installed on a CNC lathe, which includes the cryogenic coolant provision system, and which is able to hinder the part possible distortions due to the liquid nitrogen adduction by stabilizing its dimensions through the use of heating cartridges and appropriate sensors to monitor the temperature evolution of the tool holder.

  15. Explaining diversity of livestock-farming management strategies of multiple-job holders: importance of level of production objectives and role of farming in the household.

    Science.gov (United States)

    Fiorelli, C; Dedieu, B; Pailleux, J-Y

    2007-09-01

    We characterised the livestock-farming management strategies of multiple-job holders and identified which variables contributed most to the differentiation of these strategies. We hypothesised that they would mainly be differentiated by the contribution of the farming income to the total household income and the availability of the household members for farming. The multiple-job holding livestock-farmer's motivations, decisions and actions about both multiple-job holding and livestock farming were obtained in semi-directed interviews of 35 sheep farmers who held multiple jobs, on farm and off farm. They were synthesised into six variables characterising the diversity of the livestock-farming objectives and management guidelines. Thanks to a multiple factorial analysis, we showed that the diversity of the sheep-farming management strategies of multiple-job holders was better explained by two factors 'level of motivation of the farmer to get high technical results' and 'more personal fulfilling v. the family business conception of farming', than the factors we hypothesised. Within our sample, the performances ranged from 0.7 to 1.4 weaned lambs per ewe per year. Six sheep-farming management strategies were identified. They illustrated the importance of the level of production objectives and of farming income expectation, which were found to be independent, in explaining diversity. No direct relationship between farm work organisation and sheep-farming management strategy was identified. Explaining the diversity of the livestock-farming management strategies of multiple-job holders appears to require that all the benefits expected from farming and their hierarchy be identified before analysing how they are translated into production objectives and management guidelines.

  16. Social Perception of Hydrogen Technologies: The View of Spanish Stake holders; Percepcion Social de las Tecnologias del Hidrogeno. La Vision de los Stakeholders Espanoles

    Energy Technology Data Exchange (ETDEWEB)

    Ferri Anglada, S.

    2013-07-01

    This technical report presents an overview of the social perception and vision of a sample of Spanish stake holders on hydrogen technologies. The study is based on the implementation of a survey, combining both quantitative and qualitative data. An ad hoc electronic survey was design to collect views and perceptions on several key factors regarding this innovative energy alternative. The group of experts participating (N=130) in the study, comes mainly from research centers, universities and private companies. The survey addresses three major themes: expert views, social acceptability, and contextual factors of hydrogen technologies. The aim is to capture both the current and the future scene as viewed by the experts on hydrogen technologies, identifying key factors in terms of changes, uncertainties, obstacles and opportunities. The objective is to identify potential key features for the introduction, development, promotion, implementation, and large-scale deployment of a highly successful energy proposal in countries such as Iceland, one of the pioneers in base its economy on hydrogen technologies. To conclude, this report illustrates the positive engagement of a sample of Spanish stake holders towards hydrogen technologies that may prove vital in the transition towards the Hydrogen Economy in Spain. (Author)

  17. 77 FR 45648 - Notice of Cancellation of Customs Broker Licenses Due to Death of the License Holder

    Science.gov (United States)

    2012-08-01

    ... Cancellation of Customs Broker Licenses Due to Death of the License Holder AGENCY: U.S. Customs and Border... individual Customs broker licenses and any and all permits have been cancelled due to the death of the broker...

  18. The Effect of Holder Pasteurization on Nutrients and Biologically-Active Components in Donor Human Milk: A Review

    Science.gov (United States)

    Peila, Chiara; Moro, Guido E.; Bertino, Enrico; Cavallarin, Laura; Giribaldi, Marzia; Giuliani, Francesca; Cresi, Francesco; Coscia, Alessandra

    2016-01-01

    When a mother’s milk is unavailable, the best alternative is donor milk (DM). Milk delivered to Human Milk Banks should be pasteurized in order to inactivate the microbial agents that may be present. Currently, pasteurization, performed at 62.5 °C for 30 min (Holder Pasteurization, HoP), is recommended for this purpose in international guidelines. Several studies have been performed to investigate the effects of HoP on the properties of DM. The present paper has the aim of reviewing the published papers on this topic, and to provide a comparison of the reported variations of biologically-active DM components before and after HoP. This review was performed by searching the MEDLINE, EMBASE, CINHAL and Cochrane Library databases. Studies that clearly identified the HoP parameters and compared the same DM samples, before and after pasteurization, were focused on. A total of 44 articles satisfied the above criteria, and were therefore selected. The findings from the literature report variable results. A possible explanation for this may be the heterogeneity of the test protocols that were applied. Moreover, the present review spans more than five decades, and modern pasteurizers may be able to modify the degradation kinetics for heat-sensitive substances, compared to older ones. Overall, the data indicate that HoP affects several milk components, although it is difficult to quantify the degradation degree. However, clinical practices demonstrate that many beneficial properties of DM still persist after HoP. PMID:27490567

  19. Glue test results for high-precision large cryogenic lens holder

    Science.gov (United States)

    Reutlinger, A.; Mottaghibonab, A.; Gal, C.; Boesz, A.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2012-09-01

    The Near Infrared Spectrometer and Photometer (NISP) of EUCLID requires high precision large lens holders (Ø170 mm) at cryogenic temperatures (150 K). The lenses of the optical system are glued into separate lens holders, the so called adaption rings. For the selection and verification of a suitable adhesive extensive glue selection tests are performed and results presented in this paper. With potential glue candidates, handling, single lap shear, connection tension and shear tests are carried out at room temperature (RT) and 150 K (OPS). For the NISP optical system DP490 is selected as the most suitable adhesive. The test results have shown that an even distribution of the glue in the glue gap is of crucial importance for the functioning and performance of the bonded lens system. The different coefficients of thermal expansion (CTE) between lens and lens holder produce large local mechanical stress and might cause lens breakage or failure of bonding. The design of the injection channel and the gluing procedure are developed to meet the lens performance requirements. An example is shown that after thermal cycling the remaining 0.5 mm - 1 mm thick adhesive in the injection channel results in large local mechanical stresses, and hence, damage of the lens. For a successful performance of the glue interface not only an optimum glue gap of 80 - 150 μm is important, also micro-cracks of the glass at the gluing area have to be avoided. The performed glue tests with DP490 for 3 different lens/ring material combinations show sufficient mechanical tension and shear strength for bonding of the lens system. Titanium/LF5G15 and Invar/Fused Silica combinations have reached the strength of 30 MPa at RT and 50 GPa at 150 K. These results are presented on behalf of the EUCLID consortium.

  20. Evaluation of the effect of a laparoscopic robotized needle holder on ergonomics and skills.

    Science.gov (United States)

    Bensignor, Thierry; Morel, Guillaume; Reversat, David; Fuks, David; Gayet, Brice

    2016-02-01

    Laparoscopy generates technical and ergonomics difficulties due to limited degrees of freedom (DOF) of forceps. To reduce this limitation, a new 5-mm robotized needle holder with two intracorporeal DOF, Jaimy(®), has been developed. The aim of this study was to evaluate its effects on ergonomics and skills. Fourteen surgeons including eight senior and six residents were crossover randomized and stratified based on experience. Three suturing tasks were performed with both Jaimy(®) and a classic needle holder (NH): task 1: Peg-Board; task 2: hexagonal suture; task 3: frontal suture. Postural ergonomics of the dominant arm were evaluated with an ergonomics score (RULA score) thanks to motion capture, and muscular ergonomics with electromyography of six muscular groups (flexor and extensor carpis, biceps, triceps, deltoid, trapeze). Performance outcomes are a quantitative and qualitative score, and skills outcomes are the measurement of the number of movements and the path length travelled by the instrument. The RULA score showed a statistically improved posture with Jaimy(®) (p < 0.001). The cumulative muscular workload (CMW) of four muscles was not different. However, the CMW was in favor of the NH for the flexor carpi ulnaris (p < 0.001) and the triceps (p = 0.027). The number of movements was not different (p = 0.39) although the path length was shorter with Jaimy(®) (p = 0.012). The score for task 1 was in favor of the NH (p = 0.006) with a higher quantity score. Task 2 score was not different (p = 0.086): The quality part of the score was in favor of Jaimy(®) (p = 0.009) and the quantity part was higher with the NH (p = 0.04). The score for task 3 was higher with Jaimy(®) (p = 0.001). This study suggests that the use of a robotized needle holder improves both posture and the quality of laparoscopic sutures.

  1. About the Uniform H\\"older Continuity of Generalized Riemann Function

    OpenAIRE

    Bastin, F.; Nicolay, S.; Simons, L.

    2014-01-01

    In this paper, we study the uniform H\\"older continuity of the generalized Riemann function $R_{\\alpha,\\beta}$ (with $\\alpha>1$ and $\\beta>0$) defined by \\[ R_{\\alpha,\\beta}(x)=\\sum_{n=1}^{+\\infty}\\frac{\\sin(\\pi n^\\beta x)}{n^\\alpha},\\quad x\\in\\mathbb{R}, \\] using its continuous wavelet transform. In particular, we show that the exponent we find is optimal. We also analyse the behaviour of $R_{\\alpha,\\beta}$ as $\\beta$ tends to infinity.

  2. Rainwater management for increased productivity among small-holder farmers in drought prone environments

    Science.gov (United States)

    Rockström, Johan; Barron, Jennie; Fox, Patrick

    A critical analysis of conventional water resources assessments and re-visiting the on-farm water balance suggests large scopes for water productivity improvements in small-holder rainfed farming systems in drought prone environments of Eastern and Southern Africa. The paper addresses key management challenges in trying to upgrade rainfed agriculture, and presents a set of field experiences on system options for increased water productivity in small-holder farming. Implications for watershed management are discussed, and the links between water productivity for food and securing of water flow to sustain ecosystem services are briefly analysed. Focus is on sub-Saharan Africa hosting the largest food deficit and water scarcity challenges. The paper shows that there are no agro-hydrological limitations to doubling on-farm staple food yields even in drought prone environments, by producing more ;crop per drop; of rain. Field evidence is presented suggesting that meteorological dry spells are an important cause for low yield levels and it is hypothesised that this may constitute a core driver behind farmers risk aversion strategies. The dry spell induced risk perceptions contribute amongst others to soil nutrient mining due to insignificant investments in fertilisation. For many small-holder farmers in the semi-arid tropics it is simply not worth investing in fertilisation (and other external inputs) as long as the risk for crop failure remains a reality every fifth year with risk of yield reductions every second year, due to periodic water scarcity during the growing season (i.e., not necessarily cumulative water scarcity). Results are presented from field research on small-holder system innovations in the field of water harvesting and conservation tillage. Upgrading rainfed production systems through supplemental irrigation during short dry-spells is shown to dramatically increase water productivity. Downstream implications of increased upstream withdrawals of water

  3. FlexED8: the first member of a fast and flexible sample-changer family for macromolecular crystallography.

    Science.gov (United States)

    Papp, Gergely; Felisaz, Franck; Sorez, Clement; Lopez-Marrero, Marcos; Janocha, Robert; Manjasetty, Babu; Gobbo, Alexandre; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Automated sample changers are now standard equipment for modern macromolecular crystallography synchrotron beamlines. Nevertheless, most are only compatible with a single type of sample holder and puck. Recent work aimed at reducing sample-handling efforts and crystal-alignment times at beamlines has resulted in a new generation of compact and precise sample holders for cryocrystallography: miniSPINE and NewPin [see the companion paper by Papp et al. (2017, Acta Cryst., D73, 829-840)]. With full data collection now possible within seconds at most advanced beamlines, and future fourth-generation synchrotron sources promising to extract data in a few tens of milliseconds, the time taken to mount and centre a sample is rate-limiting. In this context, a versatile and fast sample changer, FlexED8, has been developed that is compatible with the highly successful SPINE sample holder and with the miniSPINE and NewPin sample holders. Based on a six-axis industrial robot, FlexED8 is equipped with a tool changer and includes a novel open sample-storage dewar with a built-in ice-filtering system. With seven versatile puck slots, it can hold up to 112 SPINE sample holders in uni-pucks, or 252 miniSPINE or NewPin sample holders, with 36 samples per puck. Additionally, a double gripper, compatible with the SPINE sample holders and uni-pucks, allows a reduction in the sample-exchange time from 40 s, the typical time with a standard single gripper, to less than 5 s. Computer vision-based sample-transfer monitoring, sophisticated error handling and automatic error-recovery procedures ensure high reliability. The FlexED8 sample changer has been successfully tested under real conditions on a beamline.

  4. Development of miniaturized light endoscope-holder robot for laparoscopic surgery.

    Science.gov (United States)

    Long, Jean-Alexandre; Cinquin, Philippe; Troccaz, Jocelyne; Voros, Sandrine; Berkelman, Peter; Descotes, Jean-Luc; Letoublon, Christian; Rambeaud, Jean-Jacques

    2007-08-01

    We have conducted experiments with an innovatively designed robot endoscope holder for laparoscopic surgery that is small and low cost. A compact light endoscope robot (LER) that is placed on the patient's skin and can be used with the patient in the lateral or dorsal supine position was tested on cadavers and laboratory pigs in order to allow successive modifications. The current control system is based on voice recognition. The range of vision is 360 degrees with an angle of 160 degrees . Twenty-three procedures were performed. The tests made it possible to advance the prototype on a variety of aspects, including reliability, steadiness, ergonomics, and dimensions. The ease of installation of the robot, which takes only 5 minutes, and the easy handling made it possible for 21 of the 23 procedures to be performed without an assistant. The LER is a camera holder guided by the surgeon's voice that can eliminate the need for an assistant during laparoscopic surgery. The ease of installation and manufacture should make it an effective and inexpensive system for use on patients in the lateral and dorsal supine positions. Randomized clinical trials will soon validate a new version of this robot prior to marketing.

  5. Impact of the Flame-Holder Heat-Transfer Characteristics on the Onset of Combustion Instability

    KAUST Repository

    Hong, Seunghyuck

    2013-10-03

    In this article, we investigate the impact of heat transfer between the flame and the flameholder on the dynamic stability characteristics of a 50-kW backward-facing step combustor. We conducted a series of tests where two backward step blocks were used, made of ceramic and stainless steel, whose thermal conductivities are 1.06 and 12 W/m/K, respectively. Stability characteristics of the two flame-holder materials were examined using measurements of the dynamic pressure and flame chemiluminescence over a range of operating conditions. Results show that with the ceramic flameholder, the onset of instability is significantly delayed in time and, for certain operating conditions, disappears altogether, whereas with the higher conductivity material, the combustor becomes increasingly unstable over a range of operating conditions. We explain these trends using the heat flux through the flameholder and the change in the burning velocity near the step wall. Results suggest a potential approach using low-thermal-conductivity material near the flame-holder as passive dynamics suppression methods. Copyright © Taylor & Francis Group, LLC.

  6. Optimal the Process Variables of Internal Grinding for Shrink Fit Tool Holder

    Science.gov (United States)

    Lin, Y. C.; Yang, G. H.; Chow, H. M.; Tsai, L. T.

    2017-12-01

    The goal of this study was to investigate the optimal variables settings in internal grinding for shrink fit tool holder. The effects of the main grinding variables on finishing responses were comprehensively investigated based on Taguchi method. The main process variables such as abrasive grain size (AGS), grinding wheel speed (GWS), feed rate for rough (FRR), depth for rough (DR), feed rate for finishing (FRF), depth for finishing (DF), dressing speed (DS), and workpiece rotational speed (WRS) were chosen to determine their effects on grinding performances related to roundness and surface roughness in the internal grinding of the shrink fit tool holder. The experimental response values were transferred to signal-to-noise (S/N) ratios, and then the significant process variables associated with the grinding performance were examined by analysis of variance (ANOVA). In addition, the optimal combination levels of the grinding variables were also obtained from the response graphs of S/N ratios to improve the surface quality of internal grinding. The experimental results show that the significant grinding variable affecting the roundness was FRF. In addition, the significant variables with regard to surface roughness were AGS, GWS, FRR, DR, DF, and DS. The optimal grinding variable settings were achieved. Consequently, the finishing characteristics of internal grinding could be enhanced to meet the requirements of modern manufacturing applications.

  7. Investigation of holder pressure and size effects in micro deep drawing of rectangular work pieces driven by piezoelectric actuator.

    Science.gov (United States)

    Aminzahed, Iman; Mashhadi, Mahmoud Mosavi; Sereshk, Mohammad Reza Vaziri

    2017-02-01

    Micro forming is a manufacturing process to fabricate micro parts with high quality and a cost effective manner. Deep drawing could be a favorable method for production of complicated parts in macro and micro sizes. In this paper piezoelectric actuator is used as a novel approach in the field of micro manufacturing. Also, in current work, investigations are conducted with four rectangular punches and blanks with various thicknesses. Blank holder pressure effects on thickness distributions, punch force, and springback are studied. According to the results of this work, increasing of blank holder pressure in scaled deep drawing, in contrast to thickness of drawn part, leads to decrease in the punch forces and springback. Furthermore, it is shown that in micro deep drawing, the effects of holder pressure on mentioned parameters can be ignored. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Report on the Installation and Preparedness of a Protochips Fusion in-situ Heating Holder for TEM

    Energy Technology Data Exchange (ETDEWEB)

    Edmondson, Philip D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    This brief report documents the procurement and installation of a Protochips Fusion (formerly Aduro) high-temperature, high stability transmission electron microscopy (TEM) specimen holder that allows for the high spatial resolution characterization of material specimens at high temperature in situ of an electron microscope. This specimen holder was specifically procured for use with The FEI Talos F200X Scanning/Transmission Electron Microscope (STEM) in Oak Ridge National Laboratory’s (ORNL’s) Low Activation Materials Development and Analysis (LAMDA) Laboratory. The Protochips Fusion holder will enable high-resolution structural and chemical analysis of irradiated materials at high temperature, becoming a unique capability worldwide, and would encourage high-quality in situ experiments to be conducted on irradiated materials.

  9. Arrangement and method for accommodating a sample in an electron microscope

    NARCIS (Netherlands)

    Zandbergen, H.W.

    1996-01-01

    Abstract of NL 9402226 (A) The invention relates to an arrangement for accommodating a sample in an electron microscope, equipped with a sample holder which comprises sample accommodation means and is designed for at least partial accommodation in an electron microscope, where at least one sample

  10. Modeling of the minimum variable blank holder force based on forming limit diagram (FLD) in deep drawing process

    Science.gov (United States)

    Candra, S.; Batan, I. M. L.; Berata, W.; Pramono, A. S.

    2017-11-01

    This paper presents the mathematical approach of minimum blank holder force to prevent wrinkling in deep drawing process of the cylindrical cup. Based on the maximum of minor-major strain ratio, the slab method was applied to determine the modeling of minimum variable blank holder force (VBHF) and it compared to FE simulation. The Tin steel sheet of T4-CA grade, with the thickness of 0.2 mm was used in this study. The modeling of minimum VBHF can be used as a simple reference to prevent wrinkling in deep drawing.

  11. Biological and social feasibility of Sesbania fallow practice in small holder agricultural farms in developing countries: a Zambian case study.

    Science.gov (United States)

    Opio, C

    2001-01-01

    Many small holder farmers in developing countries face problems of declining soil fertility and crop yields and insufficient money to buy expensive inorganic fertilizers. The Sesbania fallow system, an agroforestry technology, seems to hold a key to these problems. Based on field studies in eastern Zambia, this paper reports that fallow system has the potential to improve and sustain soil productivity in the small holder farms. However, the paper also reports that the ability for subsistence farmers to adopt the Sesbania fallow system is affected by gender differences in resource allocation to productive resources and institutional, cultural, and social structural settings in which farmers exist and make decisions.

  12. Measured Thermal and Fast Neutron Fluence Rates for ATF-1 Holders During ATR Cycle 157D

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 157D which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution.

  13. Moving Object Detection Using Scanning Camera on a High-Precision Intelligent Holder

    Directory of Open Access Journals (Sweden)

    Shuoyang Chen

    2016-10-01

    Full Text Available During the process of moving object detection in an intelligent visual surveillance system, a scenario with complex background is sure to appear. The traditional methods, such as “frame difference” and “optical flow”, may not able to deal with the problem very well. In such scenarios, we use a modified algorithm to do the background modeling work. In this paper, we use edge detection to get an edge difference image just to enhance the ability of resistance illumination variation. Then we use a “multi-block temporal-analyzing LBP (Local Binary Pattern” algorithm to do the segmentation. In the end, a connected component is used to locate the object. We also produce a hardware platform, the core of which consists of the DSP (Digital Signal Processor and FPGA (Field Programmable Gate Array platforms and the high-precision intelligent holder.

  14. 17 CFR 270.32a-2 - Exemption for initial period from vote of security holders on independent public accountant for...

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Exemption for initial period from vote of security holders on independent public accountant for certain registered separate accounts... from vote of security holders on independent public accountant for certain registered separate accounts...

  15. 26 CFR 1.1272-3 - Election by a holder to treat all interest on a debt instrument as OID.

    Science.gov (United States)

    2010-04-01

    ..., market discount, de minimis market discount, and unstated interest, as adjusted by any amortizable bond..., limitations, and special rules—(i) Debt instrument with amortizable bond premium (as determined under section 171). (A) A holder may make the election for a debt instrument with amortizable bond premium only if...

  16. 21 CFR 516.119 - Permanent-resident U.S. agent for foreign requestors and holders.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Permanent-resident U.S. agent for foreign... MINOR USE AND MINOR SPECIES Index of Legally Marketed Unapproved New Animal Drugs for Minor Species § 516.119 Permanent-resident U.S. agent for foreign requestors and holders. Every foreign requestor and...

  17. Determinants of Increasing Duration of First Unemployment among First Degree Holders in Rwanda: A Logistic Regression Analysis

    Science.gov (United States)

    Niragire, François; Nshimyiryo, Alphonse

    2017-01-01

    Unexpectedly, the duration of first unemployment among first degree holders has quickly increased in Rwanda after considerable loss of the skilled labour during the war and Genocide perpetrated against Tutsi in 1994. The time it takes a higher education graduate to land a first employment is a key indicator for the evaluation of and optimal…

  18. 37 CFR 7.24 - Requests to record security interest or other restriction of holder's rights of disposal or...

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Requests to record security interest or other restriction of holder's rights of disposal or release of such restriction submitted... THE MADRID AGREEMENT CONCERNING THE INTERNATIONAL REGISTRATION OF MARKS Recording Changes to...

  19. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 158B/159A

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States); Walker, Billy Justin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-11-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 158B/159A which were measured by the Radiation Measurements Laboratory (RML).

  20. 26 CFR 301.6323(a)-1 - Purchasers, holders of security interests, mechanic's lienors, and judgment lien creditors.

    Science.gov (United States)

    2010-04-01

    ..., mechanic's lienors, and judgment lien creditors. 301.6323(a)-1 Section 301.6323(a)-1 Internal Revenue... ADMINISTRATION Collection General Provisions § 301.6323(a)-1 Purchasers, holders of security interests, mechanic... of a security interest (as defined in paragraph (a) of § 301.6323(h)—1), mechanic's lienor (as...

  1. Does a Doctoral Degree Pay Off? An Empirical Analysis of Rates of Return of German Doctorate Holders

    Science.gov (United States)

    Mertens, Anne; Röbken, Heinke

    2013-01-01

    The empirical analysis examines differences in salaries and working time of doctorate holders in comparison to graduates with a master or equivalent degree (in Germany, the first university degree is called a "diploma" or "state examination" depending on the field of study. The diploma degree and the state examination are…

  2. Initial experience using a robotic-driven laparoscopic needle holder with ergonomic handle: assessment of surgeons' task performance and ergonomics.

    Science.gov (United States)

    Sánchez-Margallo, Juan A; Sánchez-Margallo, Francisco M

    2017-12-01

    The objective of this study is to assess the surgeons' performance and ergonomics during the use of a robotic-driven needle holder in laparoscopic suturing tasks. Six right-handed laparoscopic surgeons with different levels of experience took part in this study. Participants performed a set of three different intracorporeal suturing tasks organized in ten trials during a period of five weeks. Surgeons used both conventional (Conv) and robotic (Rob) laparoscopic needle holders. Precision using the surgical needle, quality of the intracorporeal suturing performance, execution time and leakage pressure for the urethrovesical anastomosis, as well as the ergonomics of the surgeon's hand posture, were analyzed during the first, fifth and last trials. No statistically significant differences in precision and quality of suturing performance were obtained between both groups of instruments. Surgeons required more time using the robotic instrument than using the conventional needle holder to perform the urethrovesical anastomosis, but execution time was significantly reduced after training ([Formula: see text] 0.05). There were no differences in leakage pressure for the anastomoses carried out by both instruments. After training, novice surgeons significantly improved the ergonomics of the wrist ([Formula: see text] 0.05) and index finger (Conv: 36.381[Formula: see text], Rob: 30.389[Formula: see text]; p = 0.024) when using the robotic instrument compared to the conventional needle holder. Results have shown that, although both instruments offer similar technical performance, the robotic-driven instrument results in better ergonomics for the surgeon's hand posture compared to the use of a conventional laparoscopic needle holder in intracorporeal suturing.

  3. Arrangement and method for accommodating a sample in an electron microscope

    OpenAIRE

    H.W. Zandbergen

    1996-01-01

    Abstract of NL 9402226 (A) The invention relates to an arrangement for accommodating a sample in an electron microscope, equipped with a sample holder which comprises sample accommodation means and is designed for at least partial accommodation in an electron microscope, where at least one sample mount is provided which can contain a sample in a position in which the sample is at least partially visible from the outside of the sample mount from at least two sides opposite one another, the or ...

  4. Laparoscopic cholecystectomy as solo surgery with the aid of a robotic camera holder: a case-control study.

    Science.gov (United States)

    Kalteis, Manfred; Pistrich, Renate; Schimetta, Wolfgang; Pölz, Werner

    2007-08-01

    By using robotic camera holders, a laparoscopic cholecystectomy (LC) is possible as a solo-surgeon operation. The purpose of this paper is to examine the safeness and efficiency of solo-surgeon LCs. A series of 72 solo-surgeon LCs was retrospectively compared with a control cohort (matched pairs). Efficiency and safety parameters were compared by means of equivalence tests (scope=10%). Nearly identical incision-suture times (means: 69.6 vs. 70.7 min) were recorded. An equivalence was also found in the cohorts for the total time in the operating room (means: 117.4 vs. 117.2 min). In terms of the rate of complications, the perioperative difference in hemoglobin, and the conversion rate, the robot cohort proved to be at least equal to the control cohort. The postoperative hospital stay was shorter for the robot cohort. Solo-surgeon LC with a robotic camera holder is an efficient and safe method.

  5. Shape-memory NiTi foams produced by replication of NaCl space-holders.

    Science.gov (United States)

    Bansiddhi, A; Dunand, D C

    2008-11-01

    NiTi foams were created with a structure (32-36% open pores 70-400 microm in size) and mechanical properties (4-25 GPa stiffness, >1000 MPa compressive strength, >42% compressive ductility, and shape-memory strains up to 4%) useful for bone implant applications. A mixture of NiTi and NaCl powders was hot-isostatically pressed at 950 and 1065 degrees C and the NaCl phase was then dissolved in water. The resulting NiTi foams show interconnected pores that replicate the shape and size of the NaCl powders, indicating that NiTi powders densified significantly before NaCl melted at 801 degrees C. Densifying NiTi or other metal powders above the melting point of the space-holder permits the use of NaCl, with the following advantages compared with higher-melting, solid space-holders such as oxides and fluorides used to date: (i) no temperature limit for densification; (ii) lower cost; (iii) greater flexibility in powder (and thus pore) shape; (iv) faster dissolution; (v) reduced metal corrosion during dissolution; (vi) lower toxicity if space-holder residues remain in the foam.

  6. Analysis of Fuel Vaporization, Fuel-Air Mixing, and Combustion in Integrated Mixer-Flame Holders

    Science.gov (United States)

    Deur, J. M.; Cline, M. C.

    2004-01-01

    Requirements to limit pollutant emissions from the gas turbine engines for the future High-Speed Civil Transport (HSCT) have led to consideration of various low-emission combustor concepts. One such concept is the Integrated Mixer-Flame Holder (IMFH). This report describes a series of IMFH analyses performed with KIVA-II, a multi-dimensional CFD code for problems involving sprays, turbulence, and combustion. To meet the needs of this study, KIVA-II's boundary condition and chemistry treatments are modified. The study itself examines the relationships between fuel vaporization, fuel-air mixing, and combustion. Parameters being considered include: mixer tube diameter, mixer tube length, mixer tube geometry (converging-diverging versus straight walls), air inlet velocity, air inlet swirl angle, secondary air injection (dilution holes), fuel injection velocity, fuel injection angle, number of fuel injection ports, fuel spray cone angle, and fuel droplet size. Cases are run with and without combustion to examine the variations in fuel-air mixing and potential for flashback due to the above parameters. The degree of fuel-air mixing is judged by comparing average, minimum, and maximum fuel/air ratios at the exit of the mixer tube, while flame stability is monitored by following the location of the flame front as the solution progresses from ignition to steady state. Results indicate that fuel-air mixing can be enhanced by a variety of means, the best being a combination of air inlet swirl and a converging-diverging mixer tube geometry. With the IMFH configuration utilized in the present study, flashback becomes more common as the mixer tube diameter is increased and is instigated by disturbances associated with the dilution hole flow.

  7. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    Energy Technology Data Exchange (ETDEWEB)

    Lalander, Cecilia Helena, E-mail: cecilia.lalander@slu.se [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Komakech, Allan John [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Department of Agricultural & Bio-systems Engineering, Makerere University, Kampala (Uganda); Vinnerås, Björn [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden)

    2015-05-15

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies.

  8. A systematic review of rodent pest research in Afro-Malagasy small-holder farming systems: Are we asking the right questions?

    National Research Council Canada - National Science Library

    Lourens H Swanepoel; Corrie M Swanepoel; Peter R Brown; Seth J Eiseb; Steven M Goodman; Mark Keith; Frikkie Kirsten; Herwig Leirs; Themb’alilahlwa A M Mahlaba; Rhodes H Makundi; Phanuel Malebane; Emil F von Maltitz; Apia W Massawe; Ara Monadjem; Loth S Mulungu; Grant R Singleton; Peter J Taylor; Voahangy Soarimalala

    2017-01-01

    ... habits and high reproductive rates. To quantify rodent pest impacts and identify trends in rodent pest research impacting on small-holder agriculture in the Afro-Malagasy region we did a systematic review of research outputs from 1910...

  9. Double-tilt in situ TEM holder with multiple electrical contacts and its application in MEMS-based mechanical testing of nanomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Bernal, Rodrigo A. [Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208 (United States); Ramachandramoorthy, Rajaprakash [Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208 (United States); Department of Theoretical and Applied Mechanics, Northwestern University, Evanston, IL 60208 (United States); Espinosa, Horacio D., E-mail: espinosa@northwestern.edu [Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208 (United States); Department of Theoretical and Applied Mechanics, Northwestern University, Evanston, IL 60208 (United States); iNfinitesimal LLC, Skokie, IL 60077 (United States)

    2015-09-15

    MEMS and other lab-on-a-chip systems are emerging as attractive alternatives to carry out experiments in situ the electron microscope. However, several electrical connections are usually required for operating these setups. Such connectivity is challenging inside the limited space of the TEM side-entry holder. Here, we design, implement and demonstrate a double-tilt TEM holder with capabilities for up to 9 electrical connections, operating in a high-resolution TEM. We describe the operating principle of the tilting and connection mechanisms and the physical implementation of the holder. To demonstrate the holder capabilities, we calibrate the tilting action, which has limits of ±15°, and establish the insulation resistance of the electronics to be 36 GΩ, appropriate for measurements of currents down to the nano-amp (nA) regime. Furthermore, we demonstrate tensile testing of silver nanowires using a previously developed MEMS device for mechanical testing, using the implemented holder as the platform for electronic operation and sensing. The implemented holder can potentially have broad application to other areas where MEMS or electrically-actuated setups are used to carry out in situ TEM experiments. - Highlights: • We implement a double-tilt in-situ TEM holder with 9 electrical connections. • The holder can operate in a HRTEM with 2 mm pole-piece gap and has tilt up to ±15°. • Insulation resistance of 36 GΩ allows measurement of small currents. • The setup is showcased by testing silver nanowires using MEMS in-situ TEM. • Broad application to other electrically-actuated in-situ experiments is possible.

  10. 40 CFR Appendix E to Subpart E of... - Interim Method of the Determination of Asbestos in Bulk Insulation Samples

    Science.gov (United States)

    2010-07-01

    ... manner prescribed in Reference 5 and information on design of sampling and analysis programs may be found... • Sample Mill: SPEX, Inc., freezer mill or equivalent. • Bulk Sample Holders • Silver Membrane Filters: 25...., Spex Freezer Mill, or equivalent) for a maximum time of 10 min. is recommended to obtain satisfactory...

  11. Comparison of the FreeHand® robotic camera holder with human assistants during endoscopic extraperitoneal radical prostatectomy.

    Science.gov (United States)

    Stolzenburg, Jens-Uwe; Franz, Toni; Kallidonis, Panagiotis; Minh, Do; Dietel, Anja; Hicks, James; Nicolaus, Martin; Al-Aown, Abdulrahman; Liatsikos, Evangelos

    2011-03-01

    • To assess, in a prospective randomized study, the efficiency of the FreeHand® (Prosurgics Ltd, Bracknell, UK) compared to manual camera control during the performance of endoscopic extraperitoneal radical prostatectomy (EERPE). • Three surgeons performed 50 EERPE for localized prostate cancer. In group A (n= 25), procedures were performed with manual control of the camera by the assistant, whereas group B (n= 25) patients were treated with the assistance of the FreeHand® robotic device. • The EERPE procedure was divided into several steps. • Total operation duration, time for each surgical step, number of camera movements, number of movement errors, number of times the lens was cleaned, blood loss and margin status were compared. • No statistically significant difference was observed in terms of patient age, preoperative prostate-specific antigen level, Gleason score, positive cores and prostate volume. • The average operation duration required for the performance of each step did not differ significantly between the two groups. • Significant differences in favour of the FreeHand® camera holder were observed in case of horizontal and zooming camera movement, camera cleaning and camera errors. • Vertical camera movements were performed significantly faster by the human assistant compared to the robotic camera holder. • The average total operation duration was similar for both groups. • Positive surgical margins were detected in one patient in each group (4% of the patients). • A comparison of the FreeHand® robotic camera holder with human camera control during EERPE showed a similar time requirement for the performance of each step of the procedure. • The robotic system provided accurate and fast movements of the camera without compromising the outcome of the procedure. © 2010 THE AUTHORS. BJU INTERNATIONAL © 2010 BJU INTERNATIONAL.

  12. Incorporating Corrections for the Head-Holder and Compensation Filter when Calculating Skin Dose during Fluoroscopically-Guided Interventions.

    Science.gov (United States)

    Vijayan, Sarath; Rana, Vijay K; Rudin, Stephen; Bednarek, Daniel R

    2015-03-18

    The skin dose tracking system (DTS) that we developed provides a color-coded illustration of the cumulative skin dose distribution on a 3D graphic of the patient during fluoroscopic procedures for immediate feedback to the interventionist. To improve the accuracy of dose calculation, we now have incorporated two additional important corrections (1) for the holder used to immobilize the head in neuro-interventions and (2) for the built-in compensation filters used for beam equalization. Both devices have been modeled in the DTS software so that beam intensity corrections can be made. The head-holder is modeled as two concentric hemi-cylindrical surfaces such that the path length between those surfaces can be determined for rays to individual points on the skin surface. The head-holder on the imaging system we used was measured to attenuate the primary x-rays by 10 to 20% for normal incidence, and up to 40% at non-normal incidence. In addition, three compensation filters of different shape are built into the collimator apparatus and were measured to have attenuation factors ranging from 58% to 99%, depending on kVp and beam filtration. These filters can translate and rotate in the beam and their motion is tracked by the DTS using the digital signal from the imaging system. When it is determined that a ray to a given point on the skin passes through the compensation filter, the appropriate attenuation correction is applied. These corrections have been successfully incorporated in the DTS software to provide a more accurate determination of skin dose.

  13. A novel feedback control system – Controlling the material flow in deep drawing using distributed blank-holder force

    DEFF Research Database (Denmark)

    Endelt, Benny Ørtoft; Tommerup, Søren; Danckert, Joachim

    2013-01-01

    The performance of a feedback control system is often limited by the quality of the model on which it is based, and often the controller design is based on trial and error due to insufficient modeling capabilities. A framework is proposed where the controller design is based on classical state...... on a deep drawing operation where the objective was to control material flow throughout the part using only spatial information regarding flange draw-in. The control system controls both the magnitude and distribution of the blank-holder force. The methodology proved stable and flexible with respect...

  14. Do Bolivian small holder farmers improve and retain knowledge to reduce occupational pesticide poisonings after training on Integrated Pest Management?

    DEFF Research Database (Denmark)

    Jørs, Erik; Lander, Flemming; Huici, Omar

    2014-01-01

    : A baseline survey was performed in 2002 and follow-up surveys in 2004 and 2009. Farmers were selected and trained on Integrated Pest Management (IPM) from 2002 to 2004 in Farmer Field Schools (FFS). After exclusions and drop outs, 23 FFS trained farmers could be compared to 47 neighbor farmers for changes......BACKGROUND: Pesticide consumption is increasing in Bolivia as well as pest resistance, pesticide poisonings and pollution of the environment. This survey evaluates the training of small holder farmers on pesticide handling and ecological alternatives to reduce the negative pesticide effects. METHOD...

  15. A Comparative Study on the Mechanical Behavior of Porous Titanium and NiTi Produced by a Space Holder Technique

    Science.gov (United States)

    Hosseini, S. A.; Yazdani-Rad, R.; Kazemzadeh, A.; Alizadeh, M.

    2014-03-01

    NiTi and Ti porous specimens with appropriate pore characteristics for biomedical applications are produced by space holder method. Porosities of the specimens linearly increase from 14 to 65 and 42 to 70% for the Ti and NiTi specimens, respectively, with the urea space holder. Mechanical properties such as stiffness, fracture strain, and strength of the porous NiTi and Ti are adjustable with pore characteristics. The apparent elasticity modulus of NiTi specimens decrease from 3.5 to 0.73 GPa as porosity increases. Since the initial linear part of the stress-strain curve consists of elastic behavior, formation of stress-induced martensite, deformation and/or detwinning of martensite variants, and plastic deformation, the unloading slope of stress-strain curves is a better approximation for the elasticity modulus of the NiTi porous specimens as it is proved by an isotropic cubic cell model. The unloading slope of the NiTi specimen with 61% porosity is 3.1 GPa, while the apparent elasticity or loading slope is 0.85 GPa. In comparison to Ti, the high, recoverable strain of NiTi improves capability of it as a good candidate for bone replacement. Moreover, in contrast to Ti specimens, hysteresis loops are clearly observed in the stress-strain curves of NiTi specimens.

  16. Micro/nano-mechanical test system employing tensile test holder with push-to-pull transformer

    Science.gov (United States)

    Oh, Yunje; Cyrankowski, Edward; Shan, Zhiwei; Syed Asif, Syed Amanula

    2014-07-29

    A micromachined or microelectromechanical system (MEMS) based push-to-pull mechanical transformer for tensile testing of micro-to-nanometer scale material samples including a first structure and a second structure. The second structure is coupled to the first structure by at least one flexible element that enables the second structure to be moveable relative to the first structure, wherein the second structure is disposed relative to the first structure so as to form a pulling gap between the first and second structures such that when an external pushing force is applied to and pushes the second structure in a tensile extension direction a width of the pulling gap increases so as to apply a tensile force to a test sample mounted across the pulling gap between a first sample mounting area on the first structure and a second sample mounting area on the second structure.

  17. Micro/nano-mechanical test system employing tensile test holder with push-to-pull transformer

    Science.gov (United States)

    Oh, Yunje; Cyrankowski, Edward; Shan, Zhiwei; Asif, Syed Amanula Syed

    2013-05-07

    A micromachined or microelectromechanical system (MEMS) based push-to-pull mechanical transformer for tensile testing of micro-to-nanometer scale material samples including a first structure and a second structure. The second structure is coupled to the first structure by at least one flexible element that enables the second structure to be moveable relative to the first structure, wherein the second structure is disposed relative to the first structure so as to form a pulling gap between the first and second structures such that when an external pushing force is applied to and pushes the second structure in a tensile extension direction a width of the pulling gap increases so as to apply a tensile force to a test sample mounted across the pulling gap between a first sample mounting area on the first structure and a second sample mounting area on the second structure.

  18. Cross-Cultural Comparative Analysis of Lay and Stake holder Reasoning about Fusion Energy in Spain and the UK

    Energy Technology Data Exchange (ETDEWEB)

    Prades, A.; Horlick-Jones, T.; Oltra, C.; Navajas, J.

    2009-07-01

    This report presents the results of a cross-cultural comparative analysis of two corpora of data from Spain and the UK on lay and stake holders understanding and reasoning about fusion energy. The very same novel methodological approach was applied in Spain and the UK to promote a learning and deliberative process about fusion energy. A brief description of the method is included first, followed by the description of the two corpora of data. Next the main Spanish findings data are discussed in the light of the UK data and then vice versa (in other words, we first interrogate the UK corpus of data to look for resonances or places of tension with the Spanish findings, and then the other way around). Then we present the results of evaluating the Spanish and UK group-based processes as engagement exercises. Finally, the key conclusions of this cross-cultural data analysis are summarized. (Author) 40 refs.

  19. IN VITRO EFFICACY OF EXTRACTS FROM PLANTS USED BY SMALL-HOLDER FARMERS IN THE TREATMENT OF DERMATOPHILOSIS IN CATTLE.

    Science.gov (United States)

    Ndhlovu, Daud N; Masika, Patrick J

    2017-01-01

    Bovine dermatophilosis, an important skin disease of cattle caused by Dermatophilus congolensis , negatively impacts the livelihoods of small-holder farmers in Zimbabwe. This impact is through, morbidity, loss of draught animal power, costs incurred to manage the disease, losses associated with devalued damaged hides and the resultant culling of some of the affected cattle. Due to the inaccessibility of conventional drugs to manage bovine dermatophilosis, farmers have been reported to use local medicinal plants to manage the disease. The aim of the study was to evaluate the in vitro antimicrobial activities of three plants that small-holder farmers in Zimbabwe used to manage bovine dermatophilosis. Dried plant materials were ground into powder and extracted individually using, water, 80 % acetone and 80 % methanol. The antimicrobial properties of the plants were evaluated against two Gram-negative (Escherichia coli and Pseudomonas aeruginosa) and one Gram-positive (Staphylococcus aureus) reference bacterial strains. They were further evaluated against a field isolate of Dermatophilus congolensis . The assays used were the disc diffusion, minimum inhibitory concentration (MIC) and the minimum bactericidal concentration (MBC). Acetone and methanol extracts had superior inhibitory activities than did those of water. Pterocarpus angolensis DC extracts had better inhibitory properties with absolute MIC values of 0.156 - 5 mg/ml, Cissus Quadrangularis L had MIC values in the range 0.156 - 5 mg/ml while that of Catunaregam spinosa Thunb, Terveng was 0.156 - 10 mg/ml. Dermatophilus congolensis was more sensitive to Pterocarpus angolensis DC average MIC = 0.63 mg/ml than to Cissus quadrangularis L average MIC = 1.25 mg/ml and Catunaregam. spinosa Thunb, Terveng average MIC = 2.08 mg/ml. These results suggest the potential antibacterial activities of extracts of the three plants and hence farmers are, in a way, justified in using the plants. Better results (lower MIC) could

  20. Necessity of Periodic Ophthalmological Examinations in Binocular B Class Driving Licence Holders Over 50 Years of Age.

    Science.gov (United States)

    Kurt, Ali; Öktem, Çağlar; Karabıçak Acer, Ayşe; Kocamış, Özkan; Taşdemir, Sedat

    2016-04-01

    To determine whether binocular B class driving licence (BBCDL) holders over 50 years old are in compliance with the BBCDL criteria for visual acuity, to determine the age-based prevalence of ophthalmological disorders reducing visual acuity in this group, and to investigate whether periodic ophthalmological examinations are needed in licence holders over 50 years of age. This prospective study enrolled 451 adults over 50 years old having a BBCDL. The study subjects were categorized into 3 age groups as group 1 (51-60 years), group 2 (61-70 years), and group 3 (over 71 years). The mean age of the subjects was 60.02±7.27 years; 338 (74.9%) were male and 113 (25.1%) were female. The BBCDL criteria were met by 353 (78.3%) subjects whereas 98 (21.7%) subjects did not meet them. Eighty-four (85.7%) of 98 patients not meeting BBCDL criteria still drove. The mean age of the subjects meeting BBCDL criteria (58.82±6.77 years) was significantly lower than the subjects not meeting them (64.34±7.40 years) (p<0.001). The most common pathologies in the individuals still driving despite not meeting BBCDL criteria were senile cataract (38.5%) and diabetic retinopathy (23.1%) in group 1, senile cataract (55.3%) and diabetic retinopathy (14.9%) in group 2, and senile cataract (63.6%) and senile macular degeneration+senile cataract (18.2%) in group 3. More than a fifth of individuals over 50 years old did not meet the BBCDL criteria, due predominantly to senile cataract, and the majority of these individuals continue to drive. Therefore, we believe that individuals over 50 years old who have a BBCDL should undergo periodic ophthalmological examinations.

  1. Determinants of fertilizer use among small-holder farmers in wetland ...

    African Journals Online (AJOL)

    The study modelled and estimated the fertilizer demand function for wetland farmers in Cross River State. Stratified random sampling method was used to collect cross sectional data from 130 wetland farmers with the help of a well structured questionnaire and personal interview schedules. Ordinary Least Squares Method ...

  2. 7 CFR Exhibit B-2 to Subpart B of... - Letter for Notifying Applicants, Lenders and Holders and Borrowers of Unfavorable Decision...

    Science.gov (United States)

    2010-01-01

    ... and Borrowers of Unfavorable Decision Reached at the Meeting B Exhibit B-2 to Subpart B of Part 1900... REGULATIONS GENERAL Adverse Decisions and Administrative Appeals Pt. 1900, Subpt. B, Exh. B-2 Exhibit B-2 to Subpart B of Part 1900—Letter for Notifying Applicants, Lenders and Holders and Borrowers of Unfavorable...

  3. A matter of focus: Power-holders feel more responsible after adopting a cognitive other-focus, rather than a self-focus

    NARCIS (Netherlands)

    Scholl, Annika; Sassenberg, Kai; Scheepers, Daan; Ellemers, Naomi; de Wit, Frank

    Social power implies responsibility. Yet, power-holders often follow only their own interests and overlook this responsibility. The present research illuminates how a previously adopted cognitive focus guides perceived responsibility when a person receives high (vs. low) power. In three experiments,

  4. 26 CFR 1.860E-1 - Treatment of taxable income of a residual interest holder in excess of daily accruals.

    Science.gov (United States)

    2010-04-01

    ... SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.860E-1 Treatment of taxable income of a residual interest holder in excess of daily accruals... organizational documents. (b) Treatment of residual interests held by REITs, RICs, common trust funds, and...

  5. Electron emission of cathode holder of vacuum diode of an intense electron-beam accelerator and its effect on the output voltage

    Directory of Open Access Journals (Sweden)

    Xin-Bing Cheng

    2011-04-01

    Full Text Available The vacuum diode which is used to generate relativistic electron beams is one of the most important parts of a pulsed-power modulator. In this paper, the electron emission of cathode holder of a vacuum diode and its effect on the output voltage is investigated by experiments on an intense electron-beam accelerator with 180 ns full width at half maximum and 200–500 kV output voltage. First, the field emission is analyzed and the electric field of the vacuum chamber is calculated. Then, the flatness of the output voltage is discussed before and after adding an insulation plate when a water load is used. It is found that the electron emission at the edges of the cathode holder is the main reason to cause the change of the flatness. Last, a piece of polyester film is used as a target to further show the electron emission of the cathode holder. This analysis shows that decreasing the electron emission of the cathode holder in such a pulse power modulator could be a good way to improve the quality of the output voltage.

  6. Determinants of the Job Satisfaction of PhD Holders: An Analysis by Gender, Employment Sector, and Type of Satisfaction in Spain

    Science.gov (United States)

    Escardíbul, Josep-Oriol; Afcha, Sergio

    2017-01-01

    We analyze the determinants of job satisfaction of PhD holders in Spain. Specifically, we consider overall job satisfaction as well as basic and motivational satisfaction, following Herzberg's typology (based on Maslow's hierarchy of needs). Using representative data for Spain's PhD population--collected from the Spanish Survey on Human Resources…

  7. Mapping Careers and Mobility of Doctorate Holders: Draft Guidelines, Model Questionnaire and Indicators. OECD Science, Technology and Industry Working Papers, 2007/6

    Science.gov (United States)

    Auriol, Laudeline; Felix, Bernard; Fernandez-Polcuch, Ernesto

    2007-01-01

    Human resources are recognised as being key to the creation, commercialisation and diffusion of innovation. Among them, doctorate holders are not only the most qualified in terms of educational attainment, but also those who are specifically trained to conduct research. Not much is known however about their career and mobility patterns on the…

  8. 7 CFR Exhibit B-1 to Subpart B of... - Letter for Notifying Applicants, Lender, Holders and Borrowers of Adverse Decisions Where the...

    Science.gov (United States)

    2010-01-01

    ... Borrowers of Adverse Decisions Where the Decision Is Appealable B Exhibit B-1 to Subpart B of Part 1900... REGULATIONS GENERAL Adverse Decisions and Administrative Appeals Pt. 1900, Subpt. B, Exh. B-1 Exhibit B-1 to Subpart B of Part 1900—Letter for Notifying Applicants, Lender, Holders and Borrowers of Adverse Decisions...

  9. 7 CFR Exhibit B-4 to Subpart B of... - Letter for Notifying Applicants, Lenders and Holders and Borrowers of Unfavorable Decision...

    Science.gov (United States)

    2010-01-01

    ... Used in Cases Involving Farmer Program Primary Loan Servicing Actions) B Exhibit B-4 to Subpart B of... AGRICULTURE PROGRAM REGULATIONS GENERAL Adverse Decisions and Administrative Appeals Pt. 1900, Subpt. B, Exh. B-4 Exhibit B-4 to Subpart B of Part 1900—Letter for Notifying Applicants, Lenders and Holders and...

  10. 17 CFR 270.18f-2 - Fair and equitable treatment for holders of each class or series of stock of series investment...

    Science.gov (United States)

    2010-04-01

    ... law, or otherwise, to the holders of the outstanding voting securities of a series company shall not... such company, provided that if such a majority is required by State law or otherwise, such requirement... outstanding voting securities of a company required by applicable State law or other applicable requirement...

  11. ECONOMIC ANALYSIS OF SMALL HOLDER RICE PRODUCTION SYSTEMS IN EBONYI STATE SOUTH EAST, NIGERIA

    Directory of Open Access Journals (Sweden)

    Nwaobiala C.U.

    2013-11-01

    Full Text Available Economic analysis of Upland and Swamp rice production in Ebonyi State, South east Nigeria was studied and analyzed in 2011 farming season. Purposive and multistage random sampling technique was used to select agricultural blocks, circles and rice farmers. The sample size was 240 rice farmers (120 Agricultural Development Programme (ADP Upland rice contact farmers and 120 Agricultural Development Programme (ADP Swamp contact rice farmers. Data for the analysis were collected from a structured questionnaire. The result indicates that mean ages of upland rice farmers was 37.3 years while swamp rice farmers had 39.2 years. The mean farming experience for both farmers were 8.5 years (upland rice farmers and 8.8 years (swamp rice farmers with farm sizes of 1.2 and 1.1 hectares for upland rice farmers and swamp rice farmers respectively. Upland rice farmers had an annual farm income of 189,410.00 NGN (1,222USD as against 201,166.00 NGN (1,297.85USD for Swamp rice farmers. The multiple regression (Cobb Douglas estimates of the determinants of output of upland rice showed that coefficients age, farming experience, farm size, variable inputs and farm income were positively signed at given levels of probability while capital inputs was negative. The Cobb Douglas regression estimates of the determinants of output of Swamp rice showed that the coefficients of education, labour cost, farm size, variable inputs and farm income were positively signed and significant at given levels of probability as well as capital inputs which was negative. The result indicates that net profit from Upland rice cultivation was 92,800.00 NGN (598.71USD with a Benefit Cost Ratio of N1.55 (1.56USD. The net profit from Swamp rice cultivation was 132,090.00 NGN (852.19USD and a Benefit Cost Ratio of 1.75 NGN (1.75USD. Access to credit to rice farmers, subsidy on farm inputs, dissemination of improved rice technologies by extension agents and formation of farmer groups were advocated

  12. Pre- and post construction monitoring and stake holder involvement of on-shore turbines adjacent to Severn Estuary Ramsar site

    Energy Technology Data Exchange (ETDEWEB)

    Pickering, Simon; Roberts, Lyndon; Hall, Helen

    2011-07-01

    Full text: Surveys were conducted in 2004 and winter 2006/07 prior to construction of three Enercon 2MW turbines adjacent to intertidal mudflats on Sever Estuary at Bristol Port in summer 2007. An advisory panel of stake holders was established to agree and oversee monitoring protocol and production of annual reports, public statements and modification of monitoring protocol. This had representative from the planning authority, Bristol Port, statutory nature conservations organisations, national and local nature conservation NGO's and local wildlife interests. Post construction monitoring included: . collision watch surveys . ground searches . vantage point surveys . disturbance surveys . ringed plovers breeding beneath the turbines. Since construction there has been a reduction in birds flying through the site particularly gulls. An estimated 415,000 birds annually transiting the site but no collisions have been observed or casualties found. The mean count of water bird species feeding on intertidal mudflats has been between 11%-57% higher than pre construction and the mean count of SPA wildfowl and waders species has been between 55% and 272% higher. Threshold distances for disturbance generally range from 150-300m although some species feed within 100m and roost within 50m of the turbines. Ringed plover continue to nest beneath turbines. The Advisory Panel met numerous times during the first year and despite very different interests in the site and initial views on the turbines has developed a good working relationship and now meet annually. (Author)

  13. Balanced sampling

    NARCIS (Netherlands)

    Brus, D.J.

    2015-01-01

    In balanced sampling a linear relation between the soil property of interest and one or more covariates with known means is exploited in selecting the sampling locations. Recent developments make this sampling design attractive for statistical soil surveys. This paper introduces balanced sampling

  14. The effect of sample holder geometry on electromagnetic heating of nanoparticle and NaCl solutions at 13.56 MHz.

    Science.gov (United States)

    Li, Dongxiao; Jung, Yun Suk; Kim, Hong Koo; Chen, Junda; Geller, David A; Shuba, Mikhail V; Maksimenko, Sergey A; Patch, Sarah; Forati, Ebrahim; Hanson, George W

    2012-12-01

    Electromagnetic absorption and subsequent heating of nanoparticle solutions and simple NaCl ionic solutions is examined for biomedical applications in the radiofrequency range at 13.56 MHz. It is shown via both theory and experiment that for in vitro measurements the shape of the solution container plays a major role in absorption and heating.

  15. Transient-Absorption Spectroscopy of Cis-Trans Isomerization of N,N-dimethyl-4,4'-Azodianiline with 3D-Printed Temperature-Controlled Sample Holder

    Science.gov (United States)

    Kosenkov, Dmytro; Shaw, James; Zuczek, Jennifer; Kholod, Yana

    2016-01-01

    The laboratory unit demonstrates a project based approach to teaching physical chemistry laboratory where upper-division undergraduates carry out a transient-absorption experiment investigating the kinetics of cis-trans isomerization of N,N-dimethyl-4,4'-azodianiline. Students participate in modification of a standard flash-photolysis spectrometer…

  16. Process-response coastal-recession model and its application to the Holderness coast (UK); Modelo proceso-respuesta de recesion de acantilados por variacion del nivel del mar. Aplicacion en la Costa de Holderness (Reino Unido)

    Energy Technology Data Exchange (ETDEWEB)

    Castedo, R.; Paredes, C.; Fernandez, M.; Vega, R. de la

    2012-11-01

    At the moment the development of predictive cliff-erosion models is limited from a geomorphologic perspective due to the complex interactions existing between coupled processes acting over wide scales of time and space. Current models incorporate a probabilistic framework in order to simulate coastal recession events or cliff failure and tend to assess the effects of climate change through changes in the mean sea lea level. According to this procedure, the resulting simulations of cliffs with different behaviours might produce identical annual retreat characteristics even if their potential response to changing environments may not be the same. Thus, a new process-response model is developed to incorporate the behavioural characteristics of cohesive clay coasts with a protective talus wedge under erosive processes. To this end, the model incorporates dynamic marine processes such as variations in mean sea level, tides and waves together with cliff evolution in the shape of erosion, cliff failure and the formation of foot talus deposits. Cliff erosion is calculated on the basis of sea-level changes, wave incidence, shore platform slope and the uniaxial compressive strength of the rock over each tidal cycle. After each cycle the geomechanical stability against topple movement of the cliff face is evaluated and in the event of failure, a talus wedge is formed. The model has been corroborated by an assessment of profile evolution at various locations along a rapidly retreating area on the coast of Holderness in the UK. The results represent an important step-forward in linking material properties to cliff recession processes and the subsequent long-term coastal response in the face of changing sea-level conditions. (Author) 72 refs.

  17. Multiple-pressure-tapped core holder combined with X-ray computed tomography scanning for gas-water permeability measurements of methane-hydrate-bearing sediments.

    Science.gov (United States)

    Konno, Yoshihiro; Jin, Yusuke; Uchiumi, Takashi; Nagao, Jiro

    2013-06-01

    We present a novel setup for measuring the effective gas-water permeability of methane-hydrate-bearing sediments. We developed a core holder with multiple pressure taps for measuring the pressure gradient of the gas and water phases. The gas-water flooding process was simultaneously detected using an X-ray computed tomography scanner. We successfully measured the effective gas-water permeability of an artificial sandy core with methane hydrate during the gas-water flooding test.

  18. SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Islam, N; Xiong, Z; Vijayan, S; Rudin, S; Bednarek, D [Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY (United States)

    2015-06-15

    Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with an air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant.

  19. Dishevelled binds the Discs large 'Hook' domain to activate GukHolder-dependent spindle positioning in Drosophila.

    Directory of Open Access Journals (Sweden)

    Joshua D Garcia

    Full Text Available Communication between cortical cell polarity cues and the mitotic spindle ensures proper orientation of cell divisions within complex tissues. Defects in mitotic spindle positioning have been linked to various developmental disorders and have recently emerged as a potential contributor to tumorigenesis. Despite the importance of this process to human health, the molecular mechanisms that regulate spindle orientation are not fully understood. Moreover, it remains unclear how diverse cortical polarity complexes might cooperate to influence spindle positioning. We and others have demonstrated spindle orientation roles for Dishevelled (Dsh, a key regulator of planar cell polarity, and Discs large (Dlg, a conserved apico-basal cell polarity regulator, effects which were previously thought to operate within distinct molecular pathways. Here we identify a novel direct interaction between the Dsh-PDZ domain and the alternatively spliced "I3-insert" of the Dlg-Hook domain, thus establishing a potential convergent Dsh/Dlg pathway. Furthermore, we identify a Dlg sequence motif necessary for the Dsh interaction that shares homology to the site of Dsh binding in the Frizzled receptor. Expression of Dsh enhanced Dlg-mediated spindle positioning similar to deletion of the Hook domain. This Dsh-mediated activation was dependent on the Dlg-binding partner, GukHolder (GukH. These results suggest that Dsh binding may regulate core interdomain conformational dynamics previously described for Dlg. Together, our results identify Dlg as an effector of Dsh signaling and demonstrate a Dsh-mediated mechanism for the activation of Dlg/GukH-dependent spindle positioning. Cooperation between these two evolutionarily-conserved cell polarity pathways could have important implications to both the development and maintenance of tissue homeostasis in animals.

  20. The preventive Control of White Root Rot Disease in Small Holder Rubber Plantation Using Botanical, Biological and Chemical Agents

    Directory of Open Access Journals (Sweden)

    Joko Prasetyo

    2014-03-01

    Full Text Available The preventive control of white root rot disease in small holder plantation using botanical, biological, and chemical agents. A field and laboratory experiment were conducted from June 2008 to December 2009 in Panumangan, Tulang Bawang - Lampung. The  field experiment was intended to evaluate the effect of  botanical plants (Alpinia galanga, Sansiviera auranthii, and Marantha arundinacea, biological agents (organic matter and Trichoderma spp., and chemical agents (lime and natural sulphur on the incidence of white root rot disease and population of some soil microbes. The laboratory experiment was conducted  to observe the mechanism of botanical agents  in controlling white root rot disease. In the field experiment, the treatments were applied  in the experimental plot with cassava plant infection as the indicator. The variables  examined were the incidence of  white root rot and population of soil microbes. In the laboratory experiment, culture of R. microporus was grown in PDA containing root exudate of the antagonistic plant (botanical agent. The variable examined was colony diameter of R. microporus growing in the PDA plates. The results of the  field experiment  showed that planting of the botanical agents, and application of Trichoderma spp., as well as natural sulphur, decreased the incidence of white root rot disease. The effectiveness of M. arundinacea and Trichoderma spp. was comparable to natural  sulphur. The laboratory experiment showed only root exudate of  A. galanga and  S. auranthii that were significantly inhibit the growth of R. microporus.

  1. A Tale of Two Majors: Explaining the Gender Gap in STEM Employment among Computer Science and Engineering Degree Holders

    Directory of Open Access Journals (Sweden)

    Sharon Sassler

    2017-07-01

    Full Text Available We examine factors contributing to the gender gap in employment in science, technology, engineering, and math (STEM among men and women with bachelor’s degrees in computer science and engineering, the two largest and most male-dominated STEM fields. Data come from the National Science Foundation’s (NSF Scientists and Engineers Statistical Data System (SESTAT from 1995 to 2008. Different factors are associated with persistence in STEM jobs among computer science and engineering degree holders. Conditional on receiving a degree in computer science, women are 14 percentage points less likely to work in STEM than their male counterparts. Controlling for demographic and family characteristics did little to change this gender gap. Women with degrees in engineering are approximately 8 percentage points less likely to work in STEM than men, although about half of this gap is explained by observed differences between men and women. We document a widening gender gap in STEM employment in computer science, but this gender gap narrows across college cohorts among those with degrees in engineering. Among recent computer science graduates, the gender gap in STEM employment for white, Hispanic, and black women relative to white men is even larger than for older graduates. Gender and race gaps in STEM employment for recent cohorts of engineering graduates are generally small, though younger Asian women and men no longer have an employment advantage relative to white men. Our results suggest that a one-size-fits-all approach to increasing women’s representation in the most male-dominated STEM fields may not work.

  2. Diametral compression behavior of biomedical titanium scaffolds with open, interconnected pores prepared with the space holder method.

    Science.gov (United States)

    Arifvianto, B; Leeflang, M A; Zhou, J

    2017-04-01

    Scaffolds with open, interconnected pores and appropriate mechanical properties are required to provide mechanical support and to guide the formation and development of new tissue in bone tissue engineering. Since the mechanical properties of the scaffold tend to decrease with increasing porosity, a balance must be sought in order to meet these two conflicting requirements. In this research, open, interconnected pores and mechanical properties of biomedical titanium scaffolds prepared by using the space holder method were characterized. Micro-computed tomography (micro-CT) and permeability analysis were carried out to quantify the porous structures and ascertain the presence of open, interconnected pores in the scaffolds fabricated. Diametral compression (DC) tests were performed to generate stress-strain diagrams that could be used to determine the elastic moduli and yield strengths of the scaffolds. Deformation and failure mechanisms involved in the DC tests of the titanium scaffolds were examined. The results of micro-CT and permeability analyses confirmed the presence of open, interconnected pores in the titanium scaffolds with porosity over a range of 31-61%. Among these scaffolds, a maximum specific surface area could be achieved in the scaffold with a total porosity of 5-55%. DC tests showed that the titanium scaffolds with elastic moduli and yield strengths of 0.64-3.47GPa and 28.67-80MPa, respectively, could be achieved. By comprehensive consideration of specific surface area, permeability and mechanical properties, the titanium scaffolds with porosities in a range of 50-55% were recommended to be used in cancellous bone tissue engineering. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Derfor holder stamceller sammen

    DEFF Research Database (Denmark)

    Keiding, Johanne

    2013-01-01

    Professor Joshua Brickman fra DanStem har i samarbejde med forskere fra The MRC Centre for Regenerative Medicine (CRM) ved University of Edinburgh identificeret en række faktorer, som regulerer embryonale stamcellers evne til at forny sig selv. Et af de centrale elementer er proteinet Oct4, og...

  4. Patients as Rights Holders.

    Science.gov (United States)

    Brännmark, Johan

    2017-07-01

    Autonomy and consent have been central values in Western moral and political thought for centuries. One way of understanding the bioethical models that started to develop, especially in the 1970s, is that they were about the fusion of a long-standing professional ethics with the core values underpinning modern political institutions. That there was a need for this kind of fusion is difficult to dispute, especially since the provision of health care has in most developed countries become an ever more important concern of our political institutions, with governments playing a significant role in regulating and facilitating the provision of health care and in many countries even largely organizing it. There is, nevertheless, still room for dispute about how best to achieve this fusion and how to best think about autonomy and consent in a biomedical context. The simplest model we can have is probably about how being a person is largely about having the capacity of autonomous choice and that the main mode through which we exercise autonomy is by providing informed consent. Yet, liberal democracy's core idea that human beings have a high and equal value is also found in other accounts of the person. The human-rights framework provides an alternative model for thinking about personhood and about patient care. The human-rights approach is grounded, not in an account of autonomy (although it has something to say about autonomy), but in an account of the moral and political personhood that people possess merely by being human beings. In this approach, values like dignity and integrity, both highly relevant in a bioethical context, are identified as distinct values rather than being derived from and therefore reduced to respect for autonomous choice. The human-rights approach can supplement the problematic notion of autonomy that has been central to bioethics by placing this notion in a broader, strongly pluralistic framework. © 2017 The Hastings Center.

  5. Language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik

    1998-01-01

    This article has two aims: [1] to present a revised version of the sampling method that was originally proposed in 1993 by Rijkhoff, Bakker, Hengeveld and Kahrel, and [2] to discuss a number of other approaches to language sampling in the light of our own method. We will also demonstrate how our...... sampling method is used with different genetic classifications (Voegelin & Voegelin 1977, Ruhlen 1987, Grimes ed. 1997) and argue that —on the whole— our sampling technique compares favourably with other methods, especially in the case of exploratory research....

  6. Venous Sampling

    Science.gov (United States)

    ... neck to help locate abnormally functioning glands or pituitary adenoma . This test is most often used after an unsuccessful neck exploration. Inferior petrosal sinus sampling , in which blood samples are taken from veins that drain the pituitary gland to study disorders related to pituitary hormone ...

  7. Sampling Development

    Science.gov (United States)

    Adolph, Karen E.; Robinson, Scott R.

    2011-01-01

    Research in developmental psychology requires sampling at different time points. Accurate depictions of developmental change provide a foundation for further empirical studies and theories about developmental mechanisms. However, overreliance on widely spaced sampling intervals in cross-sectional and longitudinal designs threatens the validity of…

  8. Language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik

    1998-01-01

    This article has two aims: [1] to present a revised version of the sampling method that was originally proposed in 1993 by Rijkhoff, Bakker, Hengeveld and Kahrel, and [2] to discuss a number of other approaches to language sampling in the light of our own method. We will also demonstrate how our...

  9. Environmental sampling

    Energy Technology Data Exchange (ETDEWEB)

    Puckett, J.M.

    1998-12-31

    Environmental Sampling (ES) is a technology option that can have application in transparency in nuclear nonproliferation. The basic process is to take a sample from the environment, e.g., soil, water, vegetation, or dust and debris from a surface, and through very careful sample preparation and analysis, determine the types, elemental concentration, and isotopic composition of actinides in the sample. The sample is prepared and the analysis performed in a clean chemistry laboratory (CCL). This ES capability is part of the IAEA Strengthened Safeguards System. Such a Laboratory is planned to be built by JAERI at Tokai and will give Japan an intrinsic ES capability. This paper presents options for the use of ES as a transparency measure for nuclear nonproliferation.

  10. Elevating sampling

    Science.gov (United States)

    Labuz, Joseph M.; Takayama, Shuichi

    2014-01-01

    Sampling – the process of collecting, preparing, and introducing an appropriate volume element (voxel) into a system – is often under appreciated and pushed behind the scenes in lab-on-a-chip research. What often stands in the way between proof-of-principle demonstrations of potentially exciting technology and its broader dissemination and actual use, however, is the effectiveness of sample collection and preparation. The power of micro- and nanofluidics to improve reactions, sensing, separation, and cell culture cannot be accessed if sampling is not equally efficient and reliable. This perspective will highlight recent successes as well as assess current challenges and opportunities in this area. PMID:24781100

  11. Design of a multi-axis cryogenic sample manipulator for soft X-ray and VUV spectroscopy

    Science.gov (United States)

    Wang, D. J.; Chiu, C. C.; Cheng, C. M.

    2013-03-01

    We have designed and constructed several manipulators for cryogenic samples and soft X-ray and VUV spectra. These manipulators are compatible with ultrahigh vacuum and up to six axis motions - three translational and three angular motions. Three translational and the polar angular motions are implemented with commercial stages. The azimuthal (in the beam direction) and tilting motions are driven with separate gear trains and connected to stepping motors on the top flange (100 CF). The azimuthal angular range is about ±180°, and the tilting range is from 75° to -25° the resolution is better than 0.1°. The sample position is designed to be situated at the center of the polar and azimuthal rotation axes. The tilting axis is designed with an offset to decrease the spatial interference with the analyzer for photoemission spectra. The sample is attached to the sample holder and transferred to the cryogenic stage via a load-lock system. The sample holder is cooled with a continuous-flow cryostat (Janis ST-400) via flexible copper braids. With liquids helium and nitrogen for the cryostat, the lowest temperature of the sample holder attains 9.15 K and 82.4 K, respectively. During tests, the rate of consumption of liquid helium is less than 0.8 L/h.

  12. TESTING OF THE OSCILLATIONS DAMPING CAPABILITY BY EXTERNAL TURNING WITH THE USE OF ALTERNATE BARS IN THE CONSTRUCTION OF THE TURNING TOOL HOLDER

    Directory of Open Access Journals (Sweden)

    Marten Madissoo

    2015-09-01

    Full Text Available Modern machinery is highly demanding and the requirement for producing high quality parts is crucial in modern engineering. The most important is the setting of dimensions and tolerances of the surfaces which work together. The shape- and position tolerances may raise the existence of failures and can affect the performance of different machinery. Consequently it is very important that the cutting process is as stable as possible in order to get the best quality parts and to achieve the maximum lifetime of the cutting tool. Unfortunately the machining of complex products from hard materials is accompanied by loss of stability of the cutting process, which leads to tool oscillations, causing an increasing wear of the cutting tools, reducing the lifetime of the machine actuators, which ultimately affects the quality and accuracy of processing responsible products. To avoid this kind of chatter vibrations it is possible to construct specialized cutting tools and tool holder witch reduce this kind of vibrations and can help to increase the manufacturing precision of machine components. In consequence of this the paper focuses on testing the utility effect of a cutting tool holder with alternate bars of different material structure in its construction. The different bars are made from rolled steel and have an anisotropic structure which also has different mechanical properties. This construction is considered as a method to improve the cutting stability of the cutting tool and helps to reduce the oscillations in the finishing turning. The method for the construction of the damper instrument holder with alternate bars is proposed.DOI: http://dx.doi.org/10.5755/j01.ms.21.3.7351

  13. Robotic Transnasal Endoscopic Skull Base Surgery: Systematic Review of the Literature and Report of a Novel Prototype for a Hybrid System (Brescia Endoscope Assistant Robotic Holder).

    Science.gov (United States)

    Bolzoni Villaret, Andrea; Doglietto, Francesco; Carobbio, Andrea; Schreiber, Alberto; Panni, Camilla; Piantoni, Enrico; Guida, Giovanni; Fontanella, Marco Maria; Nicolai, Piero; Cassinis, Riccardo

    2017-09-01

    Although robotics has already been applied to several surgical fields, available systems are not designed for endoscopic skull base surgery (ESBS). New conception prototypes have been recently described for ESBS. The aim of this study was to provide a systematic literature review of robotics for ESBS and describe a novel prototype developed at the University of Brescia. PubMed and Scopus databases were searched using a combination of terms, including Robotics OR Robot and Surgery OR Otolaryngology OR Skull Base OR Holder. The retrieved papers were analyzed, recording the following features: interface, tools under robotic control, force feedback, safety systems, setup time, and operative time. A novel hybrid robotic system has been developed and tested in a preclinical setting at the University of Brescia, using an industrial manipulator and readily available off-the-shelf components. A total of 11 robotic prototypes for ESBS were identified. Almost all prototypes present a difficult emergency management as one of the main limits. The Brescia Endoscope Assistant Robotic holder has proven the feasibility of an intuitive robotic movement, using the surgeon's head position: a 6 degree of freedom sensor was used and 2 light sources were added to glasses that were therefore recognized by a commercially available sensor. Robotic system prototypes designed for ESBS and reported in the literature still present significant technical limitations. Hybrid robot assistance has a huge potential and might soon be feasible in ESBS. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Is a 10-sow unit economically sustainable? A profitability assessment of productivity amongst small-holder pig farmers, Mpumalanga, South Africa.

    Science.gov (United States)

    Munzhelele, Priscilla; Oguttu, James W; Fasina, Folorunso O

    2016-05-12

    The majority of small-holder pig farmers in Mpumalanga had between 1- and 10-sow herds. The main aim of this study is to evaluate the current government agricultural intervention (supply of 10 sows and a boar) in terms of technical and economic feasibilities and ascertain whether the small-scale pig value chain system alleviates poverty. Data were obtained from 220 randomly selected small-holder pig farmers using a semi-structured questionnaire. The results showed that 58% farrowed ≤ 10 piglets/born/sow/litter, 44.2% practiced no weaning method and many fed swill and leftovers alone (41.6%). Pair-wise association revealed that the feeding of commercial feeds had a relationship with pigs in relatively good to very good body condition. Pigs in poor body condition were positively correlated with the feeding of swill alone. The economic models for the 10-sow unit proved that pig farming is unprofitable if the current management and feeding systems that operate in the commercial industry are utilised. However, only through a combination of cooperative systems, benefits of economies of scale, reduction of preweaning mortalities and structured government inputs can pig production be profitable at this scale of production.

  15. Scanning tunneling microscope with continuous flow cryostat sample cooling

    Energy Technology Data Exchange (ETDEWEB)

    Behler, S.; Rose, M.K.; Dunphy, J.C.; Ogletree, D.F.; Salmeron, M. [Materials Sciences Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, California 94720 (United States); Chapelier, C. [Departement de Recherche Fondamentale sur la Matiere Condensee, CEA/Grenoble, 38054 Grenoble Cedex 9 (France)

    1997-06-01

    We have constructed an ultrahigh vacuum scanning tunneling microscope (STM) for operation in the temperature range 20{endash}300 K. The design consists of a vibration isolated sample holder mounted on a continuous flow cryostat. By rotation and linear motion of the cryostat, the sample can be positioned in front of various surface preparation and analysis instruments contained in a single vacuum chamber. A lightweight beetle-type STM head is lowered from the top onto the sample by a linear manipulator. To minimize helium convection in the cryostat, the entire vacuum system, including a liquid helium storage Dewar, can be tilted by a few degrees perpendicular to the cryostat axis, which improves the operation. The performance of the instrument is demonstrated by atomically resolved images of the Pd(111) surface and adsorbed CO molecules. {copyright} {ital 1997 American Institute of Physics.}

  16. A matter of focus: Power-holders feel more responsible after adopting a cognitive other-focus, rather than a self-focus.

    Science.gov (United States)

    Scholl, Annika; Sassenberg, Kai; Scheepers, Daan; Ellemers, Naomi; de Wit, Frank

    2017-03-01

    Social power implies responsibility. Yet, power-holders often follow only their own interests and overlook this responsibility. The present research illuminates how a previously adopted cognitive focus guides perceived responsibility when a person receives high (vs. low) power. In three experiments, adopting a cognitive focus on another person (vs. on the self or taking over another person's perspective) promoted perceived responsibility among individuals receiving high (but not low) power in a subsequent context. This effect was specific for perceived responsibility - a cognitive focus on another person did not change the perceived opportunity to pursue goals or the perceived relationship to an interaction partner (e.g., interpersonal closeness). While prior research examined how social values (i.e., chronically caring about others) guide responsibility among those holding power, the current findings highlight that mere cognitive processes (i.e., situationally focusing attention on others) alter perceived responsibility among those just about to receive power. © 2016 The British Psychological Society.

  17. A systematic review of rodent pest research in Afro-Malagasy small-holder farming systems: Are we asking the right questions?

    Science.gov (United States)

    Swanepoel, Corrie M.; Brown, Peter R.; Eiseb, Seth J.; Goodman, Steven M.; Keith, Mark; Kirsten, Frikkie; Leirs, Herwig; Mahlaba, Themb’alilahlwa A. M.; Makundi, Rhodes H.; Malebane, Phanuel; von Maltitz, Emil F.; Massawe, Apia W.; Monadjem, Ara; Mulungu, Loth S.; Singleton, Grant R.; Taylor, Peter J.; Soarimalala, Voahangy; Belmain, Steven R.

    2017-01-01

    Rodent pests are especially problematic in terms of agriculture and public health since they can inflict considerable economic damage associated with their abundance, diversity, generalist feeding habits and high reproductive rates. To quantify rodent pest impacts and identify trends in rodent pest research impacting on small-holder agriculture in the Afro-Malagasy region we did a systematic review of research outputs from 1910 to 2015, by developing an a priori defined set of criteria to allow for replication of the review process. We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We reviewed 162 publications, and while rodent pest research was spatially distributed across Africa (32 countries, including Madagascar), there was a disparity in number of studies per country with research biased towards four countries (Tanzania [25%], Nigeria [9%], Ethiopia [9%], Kenya [8%]) accounting for 51% of all rodent pest research in the Afro-Malagasy region. There was a disparity in the research themes addressed by Tanzanian publications compared to publications from the rest of the Afro-Malagasy region where research in Tanzania had a much more applied focus (50%) compared to a more basic research approach (92%) in the rest of the Afro-Malagasy region. We found that pest rodents have a significant negative effect on the Afro-Malagasy small-holder farming communities. Crop losses varied between cropping stages, storage and crops and the highest losses occurred during early cropping stages (46% median loss during seedling stage) and the mature stage (15% median loss). There was a scarcity of studies investigating the effectiveness of various management actions on rodent pest damage and population abundance. Our analysis highlights that there are inadequate empirical studies focused on developing sustainable control methods for rodent pests and rodent pests in the Africa-Malagasy context is generally ignored as a research topic. PMID

  18. A systematic review of rodent pest research in Afro-Malagasy small-holder farming systems: Are we asking the right questions?

    Science.gov (United States)

    Swanepoel, Lourens H; Swanepoel, Corrie M; Brown, Peter R; Eiseb, Seth J; Goodman, Steven M; Keith, Mark; Kirsten, Frikkie; Leirs, Herwig; Mahlaba, Themb'alilahlwa A M; Makundi, Rhodes H; Malebane, Phanuel; von Maltitz, Emil F; Massawe, Apia W; Monadjem, Ara; Mulungu, Loth S; Singleton, Grant R; Taylor, Peter J; Soarimalala, Voahangy; Belmain, Steven R

    2017-01-01

    Rodent pests are especially problematic in terms of agriculture and public health since they can inflict considerable economic damage associated with their abundance, diversity, generalist feeding habits and high reproductive rates. To quantify rodent pest impacts and identify trends in rodent pest research impacting on small-holder agriculture in the Afro-Malagasy region we did a systematic review of research outputs from 1910 to 2015, by developing an a priori defined set of criteria to allow for replication of the review process. We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We reviewed 162 publications, and while rodent pest research was spatially distributed across Africa (32 countries, including Madagascar), there was a disparity in number of studies per country with research biased towards four countries (Tanzania [25%], Nigeria [9%], Ethiopia [9%], Kenya [8%]) accounting for 51% of all rodent pest research in the Afro-Malagasy region. There was a disparity in the research themes addressed by Tanzanian publications compared to publications from the rest of the Afro-Malagasy region where research in Tanzania had a much more applied focus (50%) compared to a more basic research approach (92%) in the rest of the Afro-Malagasy region. We found that pest rodents have a significant negative effect on the Afro-Malagasy small-holder farming communities. Crop losses varied between cropping stages, storage and crops and the highest losses occurred during early cropping stages (46% median loss during seedling stage) and the mature stage (15% median loss). There was a scarcity of studies investigating the effectiveness of various management actions on rodent pest damage and population abundance. Our analysis highlights that there are inadequate empirical studies focused on developing sustainable control methods for rodent pests and rodent pests in the Africa-Malagasy context is generally ignored as a research topic.

  19. A systematic review of rodent pest research in Afro-Malagasy small-holder farming systems: Are we asking the right questions?

    Directory of Open Access Journals (Sweden)

    Lourens H Swanepoel

    Full Text Available Rodent pests are especially problematic in terms of agriculture and public health since they can inflict considerable economic damage associated with their abundance, diversity, generalist feeding habits and high reproductive rates. To quantify rodent pest impacts and identify trends in rodent pest research impacting on small-holder agriculture in the Afro-Malagasy region we did a systematic review of research outputs from 1910 to 2015, by developing an a priori defined set of criteria to allow for replication of the review process. We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We reviewed 162 publications, and while rodent pest research was spatially distributed across Africa (32 countries, including Madagascar, there was a disparity in number of studies per country with research biased towards four countries (Tanzania [25%], Nigeria [9%], Ethiopia [9%], Kenya [8%] accounting for 51% of all rodent pest research in the Afro-Malagasy region. There was a disparity in the research themes addressed by Tanzanian publications compared to publications from the rest of the Afro-Malagasy region where research in Tanzania had a much more applied focus (50% compared to a more basic research approach (92% in the rest of the Afro-Malagasy region. We found that pest rodents have a significant negative effect on the Afro-Malagasy small-holder farming communities. Crop losses varied between cropping stages, storage and crops and the highest losses occurred during early cropping stages (46% median loss during seedling stage and the mature stage (15% median loss. There was a scarcity of studies investigating the effectiveness of various management actions on rodent pest damage and population abundance. Our analysis highlights that there are inadequate empirical studies focused on developing sustainable control methods for rodent pests and rodent pests in the Africa-Malagasy context is generally ignored as a

  20. Ecological Diversity of Soil Fauna as Ecosystem Engineers in Small-Holder Cocoa Plantation in South Konawe

    OpenAIRE

    Laode Muhammad Harjoni Kilowasid; Tati Suryati Syamsudin; Franciscus Xaverius Susilo; Endah Sulistyawati

    2012-01-01

    Taxa diversity within soil fauna functional groups can affected ecosystem functioning such as ecosystem engineers,which influence decomposition and nutrient cycling. The objective of this study is to describe ecological diversityvariation within soil fauna as ecosystem engineers in soil ecosystem of cocoa (Theobroma cacao L.) plantation.Sampling was conducted during one year period from five different ages of plantation. Soil fauna removed from soilcore using hand sorting methods. A total of ...

  1. [Critical aspects in determining total radioactivity of biological samples].

    Science.gov (United States)

    Del Vecchio, M P; Paolini, M; Corsi, C; Bauer, C

    1989-03-01

    During measurements of radioactivity in some milk samples with liquid scintillation counter (about one year after the nuclear accident of Chernobyl) we have observed an increase of the values of scintillation fluid with the passing of time. Although this enhancement is absolutely small (about 2 c.p.m. in 500 min), it is very important for an exact measurement of samples at low counting, as those tested. Our protocol of measure provides for insertion of alternate blanks and samples in the automatic sample-holders of liquid scintillation counter. The values of measurement of samples are taken during the increase phase subtracting the value of blank interpolated on the increasing straight line from c.p.m. of sample. Finally, we report the collected values of the whole radioactivity in some milk samples: at least 5-6 nCi/L contrary to about 1 nCi/L of 137Cs reported by USL. In our opinion it is important to consider the whole radioactivity as measure of the overall biological danger of radioactive samples. In fact, this measurement takes into account also biologically very dangerous radionuclides as 3H, 14C, 90Sr.

  2. Materijalna motivacija kao nosilac uspešne reorganizacije kompanije NIS (Material Motivation as the Holder of a Successful Reorganization on the Example of Company Nis

    Directory of Open Access Journals (Sweden)

    Radmila Stojanović

    2015-04-01

    Full Text Available For successful organization people are the primary development resource. Motivation and satisfaction of employees become the basis of modern organizations. Motivated employees today represent a strategic resource which gain a competitive advantage for the organization. If someone wants to motivate others, must first be able to motivate yourself. That means that if in organization exists motivated staff, there must be a motivated manager who will be able to launch employees. The aim of this paper is to emphasizes the importance of material motivation for successful business of a large company that had in the past significant organizational change. Through unstructured interviews were collected data on which was investigated the hypothesis that the material motivation of the most important holder for successful reorganization on the example of leading Serbian company for exploration, production and refining of oil and gas NIS. From the above it can be concluded that high-quality human resources management involves proper motivation system, that has been based on material incentives. In this paper, attention will be focused on monetary motivation and how a well-established system of material incentives can lead to the great success of the company that had a significant reorganization in the past. It will be shown in detail the system of material incentives and the positive results which obtained by this system, when it comes to the business of the company, which today is the most desirable employer in Serbia and the region. The paper should emphasize the benefits of a fair system of motivation which brings to an organization, but also to encourage further thinking to improve this aspect of motivation, which is a prerequisite for successful business and the basis for all other activities in the HRM. The analysis results indeed show that a system of material incentives in NIS is the holder of a successful reorganization, and the proof is the business

  3. Sampled-data active disturbance rejection output feedback control for systems with mismatched uncertainties

    Directory of Open Access Journals (Sweden)

    Jun You

    2016-12-01

    Full Text Available This article investigates the sampled-data disturbance rejection control problem for a class of non-integral-chain systems with mismatched uncertainties. Aiming to reject the adverse effects caused by general mismatched uncertainties via digital control strategy, a new generalized discrete-time extended state observer is first proposed to estimate the lumped disturbances in the sampling point. A disturbance rejection control law is then constructed in a sampled-data form, which will lead to easier implementation in practices. By carefully selecting the control gains and a sampling period sufficiently small to restrain the state growth under a zero-order-holder input, the bounded-input bounded-output stability of the hybrid closed-loop system and the disturbance rejection ability are delicately proved even the controller is dormant within two neighbor sampling points. Numerical simulation results demonstrate the feasibility and efficacy of the proposed method.

  4. Robotic Camera Assistance and Its Benefit in 1033 Traditional Laparoscopic Procedures: Prospective Clinical Trial Using a Joystick-guided Camera Holder.

    Science.gov (United States)

    Holländer, Sebastian W; Klingen, Hans Joachim; Fritz, Marliese; Djalali, Peter; Birk, Dieter

    2014-11-01

    Despite advances in instruments and techniques in laparoscopic surgery, one thing remains uncomfortable: the camera assistance. The aim of this study was to investigate the benefit of a joystick-guided camera holder (SoloAssist®, Aktormed, Barbing, Germany) for laparoscopic surgery and to compare the robotic assistance to human assistance. 1033 consecutive laparoscopic procedures were performed assisted by the SoloAssist®. Failures and aborts were documented and nine surgeons were interviewed by questionnaire regarding their experiences. In 71 of 1033 procedures, robotic assistance was aborted and the procedure was continued manually, mostly because of frequent changes of position, narrow spaces, and adverse angular degrees. One case of short circuit was reported. Emergency stop was necessary in three cases due to uncontrolled movement into the abdominal cavity. Eight of nine surgeons prefer robotic to human assistance, mostly because of a steady image and self-control. The SoloAssist® robot is a reliable system for laparoscopic procedures. Emergency shutdown was necessary in only three cases. Some minor weak spots could have been identified. Most surgeons prefer robotic assistance to human assistance. We feel that the SoloAssist® makes standard laparoscopic surgery more comfortable and further development is desirable, but it cannot fully replace a human assistant.

  5. Mitigating Against Conflicts in the Kenyan Mining Cycle: Identification of Gaps in the Participation and Recourse for Rights Holders (Civil Society & Community

    Directory of Open Access Journals (Sweden)

    Anyona Seroni

    2017-01-01

    Full Text Available One of the major obstacles to sustainable development of the mining sector in Africa is conflicts. These conflicts emanate from various sources. However one of the key sources of misunderstanding is lack of communication between the rights holders (community and duty bearers (government and corporate and this breakdown of communication is due to poor or nonexistent mechanisms of involvement of affected communities in decision making and ignorance. This study sought to examine the Kenyan Mining cycle and identify procedural and systemic gaps that if not addressed could trigger conflict in the emerging mining sector and suggest ways of mitigating them. Key among the greatest barriers to communal participation is ignorance regarding mining activities and also the language of instruction. Most rural people are uneducated and yet a large number of communication and notices are in English. Poor management of expectations is also a critical source of misunderstanding and hence conflict. Poor communal organization and lack of some sort of recognized authority give room for disorder and hence poor channels of communication.

  6. [Serological detection of Brucella suis, influenza virus and Aujeszky's disease virus in backyard and small swine holders in Argentina].

    Science.gov (United States)

    Dibarbora, Marina; Cappuccio, Javier A; Aznar, María N; Bessone, Fernando A; Piscitelli, Hernán; Pereda, Ariel J; Pérez, Daniel R

    Farmers raising less than 100 sows represent more than 99% of swine producers in Argentina, although little is known about their sanitary status and productive characteristics in the country. Sanitary and productive information was obtained. Furthermore, samples for serological studies were taken to detect antibodies against Brucella suis (Bs), Aujeszky's disease virus (AV) and influenza virus (IV) in 68 backyard and small producers with less than 100 sows located in the north, central and south regions of Argentina. Antibodies against H1 pandemic were detected in 80% of the farms while 11%, 11.7% and 6.0% of the producers were positive to influenza H3 cluster 2, AV and Bs, respectively. None of the producers was aware of the risk factors concerning the transmission of diseases from pigs to humans. A percentage of 47% of them buy pigs for breeding from other farmers and markets. With regard to biosecurity measures, only 16% of the farms had perimeter fences. The results of this study demonstrate that productive characterization and disease surveys are important to improve productivity and to reduce the risk of disease transmission among animals and humans. The study of sanitary status and risk factors is necessary for better control and eradication of diseases in backyard or small producers. More representative studies at country level should be carried out to detect the pathogensthat circulate and, with this knowledge, to implement prevention and control measures. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Systematic sampling with errors in sample locations

    DEFF Research Database (Denmark)

    Ziegel, Johanna; Baddeley, Adrian; Dorph-Petersen, Karl-Anton

    2010-01-01

    Systematic sampling of points in continuous space is widely used in microscopy and spatial surveys. Classical theory provides asymptotic expressions for the variance of estimators based on systematic sampling as the grid spacing decreases. However, the classical theory assumes that the sample grid...... is exactly periodic; real physical sampling procedures may introduce errors in the placement of the sample points. This paper studies the effect of errors in sample positioning on the variance of estimators in the case of one-dimensional systematic sampling. First we sketch a general approach to variance...

  8. Principais características da raiz de cenoura na perspectiva de agentes da cadeia produtiva Main carrot root attributes based on stake holders perceptions

    Directory of Open Access Journals (Sweden)

    Silvia S Onoyama

    2011-09-01

    Full Text Available Procurou-se verificar quais são as características mais importantes da raiz de cenoura sob a ótica dos agentes da cadeia produtiva de cenoura. Para tanto, foram realizadas visitas e entrevistas com produtores, empresas de semente, vendedores de insumos, lavadores, processadores, atacadistas e gerentes de supermercados, comparando-se esses resultados com os da pesquisa de percepção de consumidores de supermercados do Distrito Federal. Em ambos os casos, utilizou-se questionário estruturado com perguntas fechadas nas quais os entrevistados classificaram os atributos segundo notas que variaram de 1 (nenhuma importância a 5 (muito importante. Para verificar a ordenação de importância dos atributos e os contrastes das médias, utilizou-se o método estatístico de análise de dados categóricos. O resultado da pesquisa indicou que os consumidores estão preocupados com valores nutricionais, textura, cor externa e sabor da cenoura. Já os demais agentes da cadeia atentaram mais para as características relacionadas com a padronização, com a coloração externa e com o ombro verde. Foram detectadas diferenças de percepção entre os agentes da cadeia, em especial dos consumidores, para os quais foram observadas diferenças nas respostas em função do gênero, idade, grau de escolaridade, estado civil e localização do supermercado. Estes resultados são muito importantes para o direcionamento de projetos de pesquisa com cenoura, que precisa atender as exigências tanto do setor produtivo quanto dos consumidores.The present investigation aimed at elucidating the carrot attributes which stake holders view as the most important. A research was carried out with carrot growers, seed companies, supplier salespersons, washers, food processors, wholesalers and supermarket managers and was compared to the perception of consumers from supermarkets located in the Federal District of Brazil. Data sets were collected through structured interviews

  9. An Abecedary of Sampling.

    Science.gov (United States)

    Doyle, Kenneth O., Jr.

    1979-01-01

    The vocabulary of sampling is examined in order to provide a clear understanding of basic sampling concepts. The basic vocabulary of sampling (population, probability sampling, precision and bias, stratification), the fundamental grammar of sampling (random sample), sample size and response rate, and cluster, multiphase, snowball, and panel…

  10. Modern survey sampling

    CERN Document Server

    Chaudhuri, Arijit

    2014-01-01

    Exposure to SamplingAbstract Introduction Concepts of Population, Sample, and SamplingInitial RamificationsAbstract Introduction Sampling Design, Sampling SchemeRandom Numbers and Their Uses in Simple RandomSampling (SRS)Drawing Simple Random Samples with and withoutReplacementEstimation of Mean, Total, Ratio of Totals/Means:Variance and Variance EstimationDetermination of Sample SizesA.2 Appendix to Chapter 2 A.More on Equal Probability Sampling A.Horvitz-Thompson EstimatorA.SufficiencyA.LikelihoodA.Non-Existence Theorem More Intricacies Abstract Introduction Unequal Probability Sampling StrategiesPPS Sampling Exploring Improved WaysAbstract Introduction Stratified Sampling Cluster SamplingMulti-Stage SamplingMulti-Phase Sampling: Ratio and RegressionEstimationviiviii ContentsControlled SamplingModeling Introduction Super-Population ModelingPrediction Approach Model-Assisted Approach Bayesian Methods Spatial SmoothingSampling on Successive Occasions: Panel Rotation Non-Response and Not-at-Homes Weighting Adj...

  11. The diversion of stimulant medications among a convenience sample of college students with current prescriptions.

    Science.gov (United States)

    Gallucci, Andrew R; Martin, Ryan J; Usdan, Stuart L

    2015-03-01

    Diversion is defined as the unlawful channeling of regulated pharmaceuticals from legal sources to the illicit marketplace. Persons with legal prescriptions often give away or sell their medications to others. The misuse of prescription stimulant medications continues to be a problem on college campuses and a need to understand how students are obtaining stimulant medications exists. The object of the study was to identify the prevalence, correlates, and motivations associated with diversion of prescription stimulants among current prescription holders. A large sample of undergraduates (n = 1,022) between the ages of 18 and 24 enrolled at a large public university in the southeastern United States completed an in class questionnaire. Among those respondents, we identified 151 current stimulant prescription holders and analyzed the prevalence, motivations, and correlates associated with lifetime and current diversion. Overall, 58.9% of current prescription holders had given away or sold their stimulant medication during their lifetime. Those with a history of nonmedical use of prescription stimulants were almost 5 times more likely to divert their medication during their lifetime. The majority of those engaging in lifetime and current diversion medication did so infrequently. The most common motivations reported for both lifetime and current diversion were "to make extra money" and to "help during a time of high academic stress." Students who reported a history of prescription misuse were also more likely to engage in current diversion. Diversion-related behaviors should be explored further and programs aimed at the reducing these behaviors should be considered. (c) 2015 APA, all rights reserved).

  12. Magnetically-induced solid-phase microextraction fiber actuation system for quantitative headspace and liquid sampling

    Science.gov (United States)

    Harvey, Chris; Carter, Jerry; Chambers, David M.

    2017-05-23

    A magnetically-induced SPME fiber actuation system includes a SPME fiber holder and a SPME fiber holder actuator, for holding and magnetically actuating a SPME fiber assembly. The SPME fiber holder has a plunger with a magnetic material to which the SPME fiber assembly is connected, and the magnetic SPME fiber holder actuator has an elongated barrel with a loading chamber for receiving the SPME fiber assembly-connected SPME fiber holder, and an external magnet which induces axial motion of the magnetic material of the plunger to extend/retract the SPME fiber from/into the protective needle of the SPME fiber assembly.

  13. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Vavpetič, P., E-mail: primoz.vavpetic@ijs.si [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Vogel-Mikuš, K. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Jeromel, L. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Ogrinc Potočnik, N. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); FOM-Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands); Pongrac, P. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Department of Plant Physiology, University of Bayreuth, Universitätstr. 30, 95447 Bayreuth (Germany); Drobne, D.; Pipan Tkalec, Ž.; Novak, S.; Kos, M.; Koren, Š.; Regvar, M. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Pelicon, P. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia)

    2015-04-01

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on–off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm{sup 2} and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation.

  14. Particulate matter sample deposit geometry and effective filter face velocities.

    Science.gov (United States)

    McDade, Charles E; Dillner, Ann M; Indresand, Hege

    2009-09-01

    Aerosol filter face velocities can be underestimated when the sample deposit area does not cover the entire face of the filter. In many aerosol samplers, Teflon filters are backed with a metal support screen. In these samplers, air flows through the filter only in the small area upstream of each hole in the screen, resulting in a sample deposit that is an array of tiny dots that mimics the array of holes. Thus, the filter deposit area is smaller than the total filter area and the effective face velocity is greater than that calculated from the sample deposit envelope. The Interagency Monitoring of Protected Visual Environments (IMPROVE) network has used filter holders with two different screen hole arrays. The U.S. Environmental Protection Agency's Chemical Speciation Network (CSN) and the Federal Reference Method samplers also use a metal support screen, but with much smaller screen holes than IMPROVE. These networks also use larger filters and lower flow rates than those used in IMPROVE. Filter face velocities for all of these networks that are calculated using the actual deposit array area range from 1.6 to 3.5 times larger than those calculated incorrectly using the entire sample deposit envelope.

  15. Hand held sample tube manipulator, system and method

    Science.gov (United States)

    Kenny, Donald V [Liberty Township, OH; Smith, Deborah L [Liberty Township, OH; Severance, Richard A [late of Columbus, OH

    2001-01-01

    A manipulator apparatus, system and method for measuring analytes present in sample tubes. The manipulator apparatus includes a housing having a central bore with an inlet end and outlet end; a plunger mechanism with at least a portion thereof slideably disposed for reciprocal movement within the central bore, the plunger mechanism having a tubular gas channel with an inlet end and an outlet end, the gas channel inlet end disposed in the same direction as said inlet end of the central bore, wherein the inlet end of said plunger mechanism is adapted for movement so as to expel a sample tube inserted in the bore at the outlet end of the housing, the inlet end of the plunger mechanism is adapted for connection to gas supply; a first seal is disposed in the housing for sealing between the central bore and the plunger mechanism; a second seal is disposed at the outlet end of the housing for sealing between the central bore and a sample tube; a holder mounted on the housing for holding the sample tube; and a biasing mechanism for returning the plunger mechanism to a starting position.

  16. Lunar Sample Atlas

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lunar Sample Atlas provides pictures of the Apollo samples taken in the Lunar Sample Laboratory, full-color views of the samples in microscopic thin-sections,...

  17. Signal sampling circuit

    NARCIS (Netherlands)

    Louwsma, S.M.; Vertregt, Maarten

    2011-01-01

    A sampling circuit for sampling a signal is disclosed. The sampling circuit comprises a plurality of sampling channels adapted to sample the signal in time-multiplexed fashion, each sampling channel comprising a respective track-and-hold circuit connected to a respective analogue to digital

  18. Signal sampling circuit

    NARCIS (Netherlands)

    Louwsma, S.M.; Vertregt, Maarten

    2010-01-01

    A sampling circuit for sampling a signal is disclosed. The sampling circuit comprises a plurality of sampling channels adapted to sample the signal in time-multiplexed fashion, each sampling channel comprising a respective track-and-hold circuit connected to a respective analogue to digital

  19. A Mars Sample Return Sample Handling System

    Science.gov (United States)

    Wilson, David; Stroker, Carol

    2013-01-01

    We present a sample handling system, a subsystem of the proposed Dragon landed Mars Sample Return (MSR) mission [1], that can return to Earth orbit a significant mass of frozen Mars samples potentially consisting of: rock cores, subsurface drilled rock and ice cuttings, pebble sized rocks, and soil scoops. The sample collection, storage, retrieval and packaging assumptions and concepts in this study are applicable for the NASA's MPPG MSR mission architecture options [2]. Our study assumes a predecessor rover mission collects samples for return to Earth to address questions on: past life, climate change, water history, age dating, understanding Mars interior evolution [3], and, human safety and in-situ resource utilization. Hence the rover will have "integrated priorities for rock sampling" [3] that cover collection of subaqueous or hydrothermal sediments, low-temperature fluidaltered rocks, unaltered igneous rocks, regolith and atmosphere samples. Samples could include: drilled rock cores, alluvial and fluvial deposits, subsurface ice and soils, clays, sulfates, salts including perchlorates, aeolian deposits, and concretions. Thus samples will have a broad range of bulk densities, and require for Earth based analysis where practical: in-situ characterization, management of degradation such as perchlorate deliquescence and volatile release, and contamination management. We propose to adopt a sample container with a set of cups each with a sample from a specific location. We considered two sample cups sizes: (1) a small cup sized for samples matching those submitted to in-situ characterization instruments, and, (2) a larger cup for 100 mm rock cores [4] and pebble sized rocks, thus providing diverse samples and optimizing the MSR sample mass payload fraction for a given payload volume. We minimize sample degradation by keeping them frozen in the MSR payload sample canister using Peltier chip cooling. The cups are sealed by interference fitted heat activated memory

  20. Sustaining Biodiversity and Income against Climate Change through Food Value Chain System by the Small-Holder Farmers in Southern Nigeria

    Directory of Open Access Journals (Sweden)

    Asadu Charles Livinus Anija

    2016-11-01

    Full Text Available Biodiversity and sustainable income are very necessary in ecosystem stability. The food value chain (FVC introduced in Nigeria to transform agriculture is commendable because through the system farmers receive various incentives as highly subsidized inputs from government and loans of low interest rates from designated Agricultural Banks and Central Bank. However, the system encourages specialization in the production of the reference crops but intercropping and mixed cropping systems practiced by most small-holder farmers because of its inherent advantages is de-emphasized or completely abandoned. This paper presents the results of two surveys of sole pepper and maize growers in 2015 and 2016 respectively as affected by sudden stoppage of rainfall in Nsukka area. The analyses showed that on the average > 70 % of the pepper farmers lost ≈ 65 % of their pepper fields while ≈ 57 % of the maize fields were lost. For a substitute intercropping system, plantain yield data from plantain plus moringa intercrop trials carried out in 2014 and 2015 were analyzed and projected to incorporate a food crop within inter-alleys. The mean plantain yields from the trials were 20 kg plant-1 for fresh bunch and 7 suckers stand-1. Based on a 6 m x 5 m (≈330 plants ha-1 spacing and the 2016 prices of bunches and suckers, these yields translated to a minimum net income per annum of N 1 320 000.00 (N 330 000.00 from bunches and N 990 000.00 from 6 suckers (net stand-1. Proceeds from the food crop, moringa seed and leaf extracts used as liquid fertilizer took care of the cost of other inputs and cultural practices. The inter-row spacing of 6 m allows mechanical cultivation of any food crop by the farmer. This system was considered a reliable insurance against climate change and pest insurgence and can be adopted by farmers in the entire southern Nigeria because both plantain and moringa can do very well in the subregion.

  1. Information sampling behavior with explicit sampling costs

    Science.gov (United States)

    Juni, Mordechai Z.; Gureckis, Todd M.; Maloney, Laurence T.

    2015-01-01

    The decision to gather information should take into account both the value of information and its accrual costs in time, energy and money. Here we explore how people balance the monetary costs and benefits of gathering additional information in a perceptual-motor estimation task. Participants were rewarded for touching a hidden circular target on a touch-screen display. The target’s center coincided with the mean of a circular Gaussian distribution from which participants could sample repeatedly. Each “cue” — sampled one at a time — was plotted as a dot on the display. Participants had to repeatedly decide, after sampling each cue, whether to stop sampling and attempt to touch the hidden target or continue sampling. Each additional cue increased the participants’ probability of successfully touching the hidden target but reduced their potential reward. Two experimental conditions differed in the initial reward associated with touching the hidden target and the fixed cost per cue. For each condition we computed the optimal number of cues that participants should sample, before taking action, to maximize expected gain. Contrary to recent claims that people gather less information than they objectively should before taking action, we found that participants over-sampled in one experimental condition, and did not significantly under- or over-sample in the other. Additionally, while the ideal observer model ignores the current sample dispersion, we found that participants used it to decide whether to stop sampling and take action or continue sampling, a possible consequence of imperfect learning of the underlying population dispersion across trials. PMID:27429991

  2. Sampling and P-sampling expansions

    Indian Academy of Sciences (India)

    Using the hyperfinite representation of functions and generalized functions this paper develops a rigorous version of the so-called `delta method' approach to sampling theory. This yields a slightly more general version of the classical WKS sampling theorem for band-limited functions.

  3. How Sample Size Affects a Sampling Distribution

    Science.gov (United States)

    Mulekar, Madhuri S.; Siegel, Murray H.

    2009-01-01

    If students are to understand inferential statistics successfully, they must have a profound understanding of the nature of the sampling distribution. Specifically, they must comprehend the determination of the expected value and standard error of a sampling distribution as well as the meaning of the central limit theorem. Many students in a high…

  4. Chorionic Villus Sampling (CVS)

    Science.gov (United States)

    ... Pregnancy > Prenatal care > Chorionic villus sampling Chorionic villus sampling E-mail to a friend Please fill in ... It's been added to your dashboard . Chorionic villus sampling (CVS) is a prenatal test . It’s used to ...

  5. Iowa Geologic Sampling Points

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Point locations of geologic samples/files in the IGS repository. Types of samples include well cuttings, outcrop samples, cores, drillers logs, measured sections,...

  6. DNA Sampling Hook

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The DNA Sampling Hook is a significant improvement on a method of obtaining a tissue sample from a live fish in situ from an aquatic environment. A tissue sample...

  7. Samples 9 (2010)

    OpenAIRE

    Arbeitskreis Studium Populärer Musik e.V. (ASPM)

    2010-01-01

    SCHWERPUNKTTHEMA. SAMPLING IM HIPHOP Gastherausgeber: Oliver Kautny und Adam Krims. Oliver Kautny: Talkin´ All That Jazz - Ein Plädoyer für die Analyse des Sampling im HipHop (Editorial). Adam Krims: Sampling in Scholarship (english editorial). Mark Katz: Sampling before Sampling. The Link Between DJ and Producer. Sascha Klammt aka Quasi Modo: Das Sample - eine einzigartige Momentaufnahme als Basis für eine neue Komposition. Detlev Rick aka DJ Rick Ski: Die Entstehung des A...

  8. Sampling in Practice

    DEFF Research Database (Denmark)

    Petersen, Lars; Esbensen, Kim Harry

    2005-01-01

    A basic knowledge of the Theory of Sampling (TOS) and a set of only eight sampling unit operations is all the practical sampler needs to ensure representativeness of samples extracted from all kinds of lots: production batches, - truckloads, - barrels, sub-division in the laboratory, sampling...... in nature and in the field (environmental sampling, forestry, geology, biology), from raw materials or manufactory processes etc. We here can only give a brief introduction to the Fundamental Sampling Principle (FSP) and these eight Sampling Unit Operations (SUO’s). Always respecting FSP and invoking only...

  9. Sampling and P-sampling expansions

    Indian Academy of Sciences (India)

    In this paper we consider instead a non-standard approach to sampling theory. The hyperfinite representation of functions and generalized functions has been studied in an earlier paper [2], and the same notation and conventions will be used here. In particular,. PcNI denotes a given even infinite hypernatural number, 4 И ...

  10. Genetic Sample Inventory

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database archives genetic tissue samples from marine mammals collected primarily from the U.S. east coast. The collection includes samples from field programs,...

  11. Genetic Sample Inventory - NRDA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database archives genetic tissue samples from marine mammals collected in the North-Central Gulf of Mexico from 2010-2015. The collection includes samples from...

  12. Superposition Enhanced Nested Sampling

    Science.gov (United States)

    Martiniani, Stefano; Stevenson, Jacob D.; Wales, David J.; Frenkel, Daan

    2014-07-01

    The theoretical analysis of many problems in physics, astronomy, and applied mathematics requires an efficient numerical exploration of multimodal parameter spaces that exhibit broken ergodicity. Monte Carlo methods are widely used to deal with these classes of problems, but such simulations suffer from a ubiquitous sampling problem: The probability of sampling a particular state is proportional to its entropic weight. Devising an algorithm capable of sampling efficiently the full phase space is a long-standing problem. Here, we report a new hybrid method for the exploration of multimodal parameter spaces exhibiting broken ergodicity. Superposition enhanced nested sampling combines the strengths of global optimization with the unbiased or athermal sampling of nested sampling, greatly enhancing its efficiency with no additional parameters. We report extensive tests of this new approach for atomic clusters that are known to have energy landscapes for which conventional sampling schemes suffer from broken ergodicity. We also introduce a novel parallelization algorithm for nested sampling.

  13. Mold Testing or Sampling

    Science.gov (United States)

    In most cases, if visible mold growth is present, sampling is unnecessary. Since no EPA or other federal limits have been set for mold or mold spores, sampling cannot be used to check a building's compliance with federal mold standards.

  14. Chorionic villus sampling

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003406.htm Chorionic villus sampling To use the sharing features on this page, please enable JavaScript. Chorionic villus sampling (CVS) is a test some pregnant women have ...

  15. Sampling on Quasicrystals

    OpenAIRE

    Grepstad, Sigrid

    2011-01-01

    We prove that quasicrystals are universal sets of stable sampling in any dimension. Necessary and sufficient density conditions for stable sampling and interpolation sets in one dimension are studied in detail.

  16. Superposition Enhanced Nested Sampling

    Directory of Open Access Journals (Sweden)

    Stefano Martiniani

    2014-08-01

    Full Text Available The theoretical analysis of many problems in physics, astronomy, and applied mathematics requires an efficient numerical exploration of multimodal parameter spaces that exhibit broken ergodicity. Monte Carlo methods are widely used to deal with these classes of problems, but such simulations suffer from a ubiquitous sampling problem: The probability of sampling a particular state is proportional to its entropic weight. Devising an algorithm capable of sampling efficiently the full phase space is a long-standing problem. Here, we report a new hybrid method for the exploration of multimodal parameter spaces exhibiting broken ergodicity. Superposition enhanced nested sampling combines the strengths of global optimization with the unbiased or athermal sampling of nested sampling, greatly enhancing its efficiency with no additional parameters. We report extensive tests of this new approach for atomic clusters that are known to have energy landscapes for which conventional sampling schemes suffer from broken ergodicity. We also introduce a novel parallelization algorithm for nested sampling.

  17. Lunar Sample Compendium

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of the Lunar Sample Compendium is to inform scientists, astronauts and the public about the various lunar samples that have been returned from the Moon....

  18. Developing Water Sampling Standards

    Science.gov (United States)

    Environmental Science and Technology, 1974

    1974-01-01

    Participants in the D-19 symposium on aquatic sampling and measurement for water pollution assessment were informed that determining the extent of waste water stream pollution is not a cut and dry procedure. Topics discussed include field sampling, representative sampling from storm sewers, suggested sampler features and application of improved…

  19. IAEA Sampling Plan

    Energy Technology Data Exchange (ETDEWEB)

    Geist, William H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-15

    The objectives for this presentation are to describe the method that the IAEA uses to determine a sampling plan for nuclear material measurements; describe the terms detection probability and significant quantity; list the three nuclear materials measurement types; describe the sampling method applied to an item facility; and describe multiple method sampling.

  20. Aerosol sampling system

    Science.gov (United States)

    Masquelier, Donald A.

    2004-02-10

    A system for sampling air and collecting particulate of a predetermined particle size range. A low pass section has an opening of a preselected size for gathering the air but excluding particles larger than the sample particles. An impactor section is connected to the low pass section and separates the air flow into a bypass air flow that does not contain the sample particles and a product air flow that does contain the sample particles. A wetted-wall cyclone collector, connected to the impactor section, receives the product air flow and traps the sample particles in a liquid.

  1. Sample Proficiency Test exercise

    Energy Technology Data Exchange (ETDEWEB)

    Alcaraz, A; Gregg, H; Koester, C

    2006-02-05

    The current format of the OPCW proficiency tests has multiple sets of 2 samples sent to an analysis laboratory. In each sample set, one is identified as a sample, the other as a blank. This method of conducting proficiency tests differs from how an OPCW designated laboratory would receive authentic samples (a set of three containers, each not identified, consisting of the authentic sample, a control sample, and a blank sample). This exercise was designed to test the reporting if the proficiency tests were to be conducted. As such, this is not an official OPCW proficiency test, and the attached report is one method by which LLNL might report their analyses under a more realistic testing scheme. Therefore, the title on the report ''Report of the Umpteenth Official OPCW Proficiency Test'' is meaningless, and provides a bit of whimsy for the analyses and readers of the report.

  2. The Lunar Sample Compendium

    Science.gov (United States)

    Meyer, Charles

    2009-01-01

    The Lunar Sample Compendium is a succinct summary of the data obtained from 40 years of study of Apollo and Luna samples of the Moon. Basic petrographic, chemical and age information is compiled, sample-by-sample, in the form of an advanced catalog in order to provide a basic description of each sample. The LSC can be found online using Google. The initial allocation of lunar samples was done sparingly, because it was realized that scientific techniques would improve over the years and new questions would be formulated. The LSC is important because it enables scientists to select samples within the context of the work that has already been done and facilitates better review of proposed allocations. It also provides back up material for public displays, captures information found only in abstracts, grey literature and curatorial databases and serves as a ready access to the now-vast scientific literature.

  3. Fast mixing hyperdynamic sampling

    OpenAIRE

    Sminchisescu, Cristian; Triggs, Bill

    2006-01-01

    Special issue on ECCV'02 papers; International audience; Sequential random sampling (‘Markov Chain Monte-Carlo') is a popular strategy for many vision problems involving multi-modal distributions over high-dimensional parameter spaces. It applies both to importance sampling (where one wants to sample points according to their ‘importance' for some calculation, but otherwise fairly) and to global-optimization (where one wants to find good minima, or at least good starting points for local mini...

  4. Hyperdynamics Importance Sampling

    OpenAIRE

    Sminchisescu, Cristian; Triggs, Bill

    2002-01-01

    International audience; Sequential random sampling (‘Markov Chain Monte-Carlo') is a popular strategy for many vision problems involving multimodal distributions over high-dimensional parameter spaces. It applies both to importance sampling (where one wants to sample points according to their ‘importance' for some calculation, but otherwise fairly) and to global optimization (where one wants to find good minima, or at least good starting points for local minimization, regardless of fairness)....

  5. Laboratory Sampling Guide

    Science.gov (United States)

    2012-05-11

    Barium  Beryllium  Cadmium  Chromium  Cobalt  Copper  Iron  Lead  Magnesium  Manganese  Molybdenum  Potassium  Nickel...paper or MCE filters Aluminum Antimony Arsenic Barium Beryllium Cadmium Chromium(Total) Cobalt Copper Iron Lead Manganese Molybdenum...Sampling Equipment Selection Guidea Matrix Sampling Device Image Device-Specific Guidance Sample Type Comments L iq ui ds Automatic sampler ASTM D

  6. An environmental sample chamber for reliable scanning transmission x-ray microscopy measurements under water vapor

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Stephen T.; Nigge, P.; Prakash, Shruti; Laskin, Alexander; Wang, Bingbing; Tyliszczak, Tolek; Leone, Stephen R.; Gilles, Mary K.

    2013-08-01

    We have designed, fabricated, and tested a compact gas-phase reactor for performing in situ soft x-ray scanning transmission x-ray microscopy (STXM) measurements. The reactor accommodates many gas atmospheres, including reactive or corrosive gasses, but was designed specically to address the needs of measurements under water vapor. An on-board sensor measures the relative humidity and temperature inside the reactor, minimizing uncertainties associated with measuring these quantities outside the instrument. The reactor mounts directly to the existing sample holder used in the majority of STXM instruments around the world and installs with minimal instrument reconguration. Using the reactor contributes over 85% less additional absorption compared to lling the STXM chamber with process gas, and results in much more stable imaging conditions. The reactor is in use at the STXM instruments at beamlines 11.0.2 and 5.3.2.2 at the Advanced Light Source.

  7. Sample size methodology

    CERN Document Server

    Desu, M M

    2012-01-01

    One of the most important problems in designing an experiment or a survey is sample size determination and this book presents the currently available methodology. It includes both random sampling from standard probability distributions and from finite populations. Also discussed is sample size determination for estimating parameters in a Bayesian setting by considering the posterior distribution of the parameter and specifying the necessary requirements. The determination of the sample size is considered for ranking and selection problems as well as for the design of clinical trials. Appropria

  8. Sample Differentiation: Cocaine Example.

    Science.gov (United States)

    Baugh, L D; Liu, R H

    1991-12-01

    Since the analyses of drug samples in crime laboratories are often associated with investigations, potential differentiations of test samples are frequently requested and explored. Cocaine sample differentiation requires the determination of synthetic or natural origin. Synthetic samples are characterized by the presence of optical isomers, certain diastereoisomers and other by-products, and chemical residues used in synthesis. Samples derived from a natural origin (coca leaves) are characterized by the presence of certain natural products or their derivatives that are carried through the overall process and by residual chemicals reflecting the treatment procedures. Various approaches and analytical data available in the literature concerning the differentiation of cocaine samples are reviewed. Each sample must carry its own "signature"; however, true sample "individualization" cannot be accomplished using the technologies commonly available and used in crime laboratories, and is not usually needed. Alternatively, "classifying" cocaine samples in certain categories or groups can be accomplished routinely and often provides adequate information for investigatory purposes. Copyright © 1991 Central Police University.

  9. Peningkatan Produktivitas Domba pada Skala Peternakan Rakyat Melalui Pemberian Hormon Pregnant Mare Serum Gonadotrophin (IMPROVEMENT OF SMALL HOLDER FARMS SHEEP PRODUCTIVITY THROUGH THE APPLICATION OF PREGNANT MARE SERUM GONADOTROPHIN

    Directory of Open Access Journals (Sweden)

    Andriyanto .

    2013-07-01

    Full Text Available The administration of Pregnant Mare Serum Gonadotrophin (PMSG hormone to stimulate superovulation has been proven to improved fetal prenatal growth, birth weight, mammary gland growth anddevelopment, milk production, litter size, as well as pre and post weaning growth. This study was conductedto apply the administration of PMSG hormone technology in small-holder farms. One hundred ewes weredivided into two groups. Group I (control: 50 ewes ewes without administration of PMSG and Group 2(treatment: 50 ewes ewes with administration of PMSG to stimulate super ovulation and improveendogenous secretion of pregnant hormones. The application of PMSG increased the numbers of lamb bornby 26.8% (69 vs. 87 with average litter size of 20.7% (1.38 vs. 1.74. The lamb weight at birth was alsoincreased by 25.7% (2.76 ± 0.33 vs. 3.47 ± 0.35 kg. The milk production of the dam was also increased by29.7% (0.64 ± 0.25 vs. 0.91 ± 0.22 L/ewe/day. Lambs born to ewes administered PMSG had better weaningweight 22.1% (12.32 ± 2.44 vs. 15.04 ± 1.11 kg/ewe. The number of survival lamb to reach weaning age washigher compared to the control group. The weight at weaning age was almost twice (628.4 kg vs. 1202.8 kgcompared to the control group. Using simple economic analysis calculation, the application of this hormonetechnology could increase gross revenue by Rp 294.280- per ewes. It was concluded that the administrationof PMSG is economically feasible to be applied in to the small-holder farms.

  10. Industrial Hygiene Sampling Instructions

    Science.gov (United States)

    1987-03-01

    transport . g. Field blank tubes will be submitted with each set of samples. If the number of samples in a set exceeds 10, then submit at the rate of one...2 Gelman PSPJ037 (For PAH) 37 2 Membrana ’ - PVC 37 5 Gelman 66467 37 5 Nuclepore 361850 Filter only 240810 Pad only Swinnex Cassette 13 - Millipore

  11. Simple street tree sampling

    Science.gov (United States)

    David J. Nowak; Jeffrey T. Walton; James Baldwin; Jerry. Bond

    2015-01-01

    Information on street trees is critical for management of this important resource. Sampling of street tree populations provides an efficient means to obtain street tree population information. Long-term repeat measures of street tree samples supply additional information on street tree changes and can be used to report damages from catastrophic events. Analyses of...

  12. Sampling system and method

    Science.gov (United States)

    Decker, David L.; Lyles, Brad F.; Purcell, Richard G.; Hershey, Ronald Lee

    2013-04-16

    The present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit.

  13. Extraterrestrial Samples at JSC

    Science.gov (United States)

    Allen, Carlton C.

    2007-01-01

    A viewgraph presentation on the curation of extraterrestrial samples at NASA Johnson Space Center is shown. The topics include: 1) Apollo lunar samples; 2) Meteorites from Antarctica; 3) Cosmic dust from the stratosphere; 4) Genesis solar wind ions; 5) Stardust comet and interstellar grains; and 5) Space-Exposed Hardware.

  14. Gaussian Boson Sampling

    Science.gov (United States)

    Hamilton, Craig S.; Kruse, Regina; Sansoni, Linda; Barkhofen, Sonja; Silberhorn, Christine; Jex, Igor

    2017-10-01

    Boson sampling has emerged as a tool to explore the advantages of quantum over classical computers as it does not require universal control over the quantum system, which favors current photonic experimental platforms. Here, we introduce Gaussian Boson sampling, a classically hard-to-solve problem that uses squeezed states as a nonclassical resource. We relate the probability to measure specific photon patterns from a general Gaussian state in the Fock basis to a matrix function called the Hafnian, which answers the last remaining question of sampling from Gaussian states. Based on this result, we design Gaussian Boson sampling, a #P hard problem, using squeezed states. This demonstrates that Boson sampling from Gaussian states is possible, with significant advantages in the photon generation probability, compared to existing protocols.

  15. Sample pretretment in microsystems

    DEFF Research Database (Denmark)

    Perch-Nielsen, Ivan R.

    2003-01-01

    When a sample, e.g. from a patient, is processed using conventional methods, the sample must be transported to the laboratory where it is analyzed, after which the results is sent back. By integrating the separate steps of the analysis in a micro total analysis system (μTAS), results can......: Sample preparation → DNA amplification → DNA analysis. The overall goal of the project is integration of as many as possible of these steps. This thesis covers mainly pretreatment in a microchip. Some methods for sample pretreatment have been tested. Most conventional is fluorescence activated cell sort...... be obtained fast and better. Preferably with all the processes from sample to signal moved to the bedside of the patient. Of course there is still much to learn and study in the process of miniaturization. DNA analysis is one process subject to integration. There are roughly three steps in a DNA analysis...

  16. Biological sample collector

    Science.gov (United States)

    Murphy, Gloria A [French Camp, CA

    2010-09-07

    A biological sample collector is adapted to a collect several biological samples in a plurality of filter wells. A biological sample collector may comprise a manifold plate for mounting a filter plate thereon, the filter plate having a plurality of filter wells therein; a hollow slider for engaging and positioning a tube that slides therethrough; and a slide case within which the hollow slider travels to allow the tube to be aligned with a selected filter well of the plurality of filter wells, wherein when the tube is aligned with the selected filter well, the tube is pushed through the hollow slider and into the selected filter well to sealingly engage the selected filter well and to allow the tube to deposit a biological sample onto a filter in the bottom of the selected filter well. The biological sample collector may be portable.

  17. Rapid Active Sampling Package

    Science.gov (United States)

    Peters, Gregory

    2010-01-01

    A field-deployable, battery-powered Rapid Active Sampling Package (RASP), originally designed for sampling strong materials during lunar and planetary missions, shows strong utility for terrestrial geological use. The technology is proving to be simple and effective for sampling and processing materials of strength. Although this originally was intended for planetary and lunar applications, the RASP is very useful as a powered hand tool for geologists and the mining industry to quickly sample and process rocks in the field on Earth. The RASP allows geologists to surgically acquire samples of rock for later laboratory analysis. This tool, roughly the size of a wrench, allows the user to cut away swaths of weathering rinds, revealing pristine rock surfaces for observation and subsequent sampling with the same tool. RASPing deeper (.3.5 cm) exposes single rock strata in-situ. Where a geologist fs hammer can only expose unweathered layers of rock, the RASP can do the same, and then has the added ability to capture and process samples into powder with particle sizes less than 150 microns, making it easier for XRD/XRF (x-ray diffraction/x-ray fluorescence). The tool uses a rotating rasp bit (or two counter-rotating bits) that resides inside or above the catch container. The container has an open slot to allow the bit to extend outside the container and to allow cuttings to enter and be caught. When the slot and rasp bit are in contact with a substrate, the bit is plunged into it in a matter of seconds to reach pristine rock. A user in the field may sample a rock multiple times at multiple depths in minutes, instead of having to cut out huge, heavy rock samples for transport back to a lab for analysis. Because of the speed and accuracy of the RASP, hundreds of samples can be taken in one day. RASP-acquired samples are small and easily carried. A user can characterize more area in less time than by using conventional methods. The field-deployable RASP used a Ni

  18. Contributions to sampling statistics

    CERN Document Server

    Conti, Pier; Ranalli, Maria

    2014-01-01

    This book contains a selection of the papers presented at the ITACOSM 2013 Conference, held in Milan in June 2013. ITACOSM is the bi-annual meeting of the Survey Sampling Group S2G of the Italian Statistical Society, intended as an international  forum of scientific discussion on the developments of theory and application of survey sampling methodologies and applications in human and natural sciences. The book gathers research papers carefully selected from both invited and contributed sessions of the conference. The whole book appears to be a relevant contribution to various key aspects of sampling methodology and techniques; it deals with some hot topics in sampling theory, such as calibration, quantile-regression and multiple frame surveys, and with innovative methodologies in important topics of both sampling theory and applications. Contributions cut across current sampling methodologies such as interval estimation for complex samples, randomized responses, bootstrap, weighting, modeling, imputati...

  19. Sample quality criteria.

    Science.gov (United States)

    Ramsey, Charles A; Wagner, Claas

    2015-01-01

    The concept of Sample Quality Criteria (SQC) is the initial step in the scientific approach to representative sampling. It includes the establishment of sampling objectives, Decision Unit (DU), and confidence. Once fully defined, these criteria serve as input, in addition to material properties, to the Theory of Sampling for developing a representative sampling protocol. The first component of the SQC establishes these questions: What is the analyte(s) of concern? What is the concentration level of interest of the analyte(s)? How will inference(s) be made from the analytical data to the DU? The second component of the SQC establishes the DU, i.e., the scale at which decisions are to be made. On a large scale, a DU could be a ship or rail car; examples for small-scale DUs are individual beans, seeds, or kernels. A well-defined DU is critical because it defines the spatial and temporal boundaries of sample collection. SQC are not limited to a single DU; they can also include multiple DUs. The third SQC component, the confidence, establishes the desired probability that a correct inference (decision) can be made. The confidence level should typically correlate to the potential consequences of an incorrect decision (e.g., health or economic). The magnitude of combined errors in the sampling, sample processing and analytical protocols determines the likelihood of an incorrect decision. Thus, controlling error to a greater extent increases the probability of a correct decision. The required confidence level directly affects the sampling effort and QC measures.

  20. Inference for Noisy Samples

    Directory of Open Access Journals (Sweden)

    I. A. Ahmad

    2012-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE In the current work, some well-known inference procedures including testing and estimation are adjusted to accommodate noisy data that lead to nonidentically distributed sample.  The main two cases addressed are the Poisson and the normal distributions. Both one and two sample cases are addressed.  Other cases including the exponential and the Pareto distributions are briefly mentioned.  In the Poisson case, the situation when the sample size is random is mentioned.

  1. Florentine Renaissance Resources. Online Tratte of Office Holders 1282-1532, Ed. by D. Herlihy, R. Burr Litchfield, A. Molho, R. Barducci, 2000. Online Catasto of 1427, Ed. by D. Herlihy, C. Klapisch-Zuber, Vers. 1.2., Brown University, Providence, R.I.

    Directory of Open Access Journals (Sweden)

    Marco Bicchierai

    2002-12-01

    Full Text Available Florentine Renaissance Resources. - Online Tratte of Office Holders 1282-1532, Edited by David Herlihy, R. Burr Litchfield, Anthony Molho and Roberto Barducci , 2000 - Online Catasto of 1427, Edited by David Herlihy, Christiane Klapisch-Zuber, Version 1.2., Brown University, Providence, R.I. , 1996

  2. The course of co-option: Co-option of local power-holders as a tool for obtaining control over the population in counterinsurgency campaigns in weblike societies. With case studies on Dutch experiences during the Aceh War (1873-c. 1912) and the Uruzgan campaign (2006-2010)

    NARCIS (Netherlands)

    Kitzen, M.W.M.

    2016-01-01

    During the counterinsurgency campaigns in Iraq and Afghanistan co-option of local power-holders proved instrumental in establishing control over the population of highly fragmented, weblike societies. This marked the reinvention of such co-option, since it had been a standard tool of the colonial

  3. Lunar Sample Display Locations

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA provides a number of lunar samples for display at museums, planetariums, and scientific expositions around the world. Lunar displays are open to the public....

  4. Sample Return Robot Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Challenge requires demonstration of an autonomous robotic system to locate and collect a set of specific sample types from a large planetary analog area and...

  5. Open port sampling interface

    Science.gov (United States)

    Van Berkel, Gary J

    2017-04-25

    A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate, the first volumetric flow rate exceeding the second volumetric flow rate, wherein liquid at the open end will receive sample, liquid containing sample material will be drawn into and through the liquid exhaust conduit, and liquid will overflow from the open end.

  6. Open port sampling interface

    Energy Technology Data Exchange (ETDEWEB)

    Van Berkel, Gary J.

    2018-01-16

    A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate, the first volumetric flow rate exceeding the second volumetric flow rate, wherein liquid at the open end will receive sample, liquid containing sample material will be drawn into and through the liquid exhaust conduit, and liquid will overflow from the open end.

  7. Stardust Sample Catalog

    Data.gov (United States)

    National Aeronautics and Space Administration — This Catalog summarizes the samples examined in the course of the Preliminary Examination (PE) Team (PET) of the Stardust Mission to comet Wild 2, and the results of...

  8. Roadway sampling evaluation.

    Science.gov (United States)

    2014-09-01

    The Florida Department of Transportation (FDOT) has traditionally required that all sampling : and testing of asphalt mixtures be at the Contractors production facility. With recent staffing cuts, as : well as budget reductions, FDOT has been cons...

  9. UFA Auction Sampling Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Between 1984 January - 2002 June, personnel from NMFS/PIFSC/FRMD/FMB/FMAP and Hawaii Department of Aquatic Resources (DAR) conducted port sampling at the United...

  10. Sample Encapsulation Device Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA's Science Mission Directorate is currently considering various sample cache and return missions to the Moon, Mars and asteroids. These missions involve the use...

  11. Mini MAX - Medicaid Sample

    Data.gov (United States)

    U.S. Department of Health & Human Services — To facilitate wider use of MAX, CMS contracted with Mathematica to convene a technical expert panel (TEP) and determine the feasibility of creating a sample file for...

  12. Dissolution actuated sample container

    Science.gov (United States)

    Nance, Thomas A.; McCoy, Frank T.

    2013-03-26

    A sample collection vial and process of using a vial is provided. The sample collection vial has an opening secured by a dissolvable plug. When dissolved, liquids may enter into the interior of the collection vial passing along one or more edges of a dissolvable blocking member. As the blocking member is dissolved, a spring actuated closure is directed towards the opening of the vial which, when engaged, secures the vial contents against loss or contamination.

  13. Two phase sampling

    CERN Document Server

    Ahmad, Zahoor; Hanif, Muhammad

    2013-01-01

    The development of estimators of population parameters based on two-phase sampling schemes has seen a dramatic increase in the past decade. Various authors have developed estimators of population using either one or two auxiliary variables. The present volume is a comprehensive collection of estimators available in single and two phase sampling. The book covers estimators which utilize information on single, two and multiple auxiliary variables of both quantitative and qualitative nature. Th...

  14. Sample size for beginners.

    OpenAIRE

    Florey, C D

    1993-01-01

    The common failure to include an estimation of sample size in grant proposals imposes a major handicap on applicants, particularly for those proposing work in any aspect of research in the health services. Members of research committees need evidence that a study is of adequate size for there to be a reasonable chance of a clear answer at the end. A simple illustrated explanation of the concepts in determining sample size should encourage the faint hearted to pay more attention to this increa...

  15. Wet gas sampling

    Energy Technology Data Exchange (ETDEWEB)

    Welker, T.F.

    1997-07-01

    The quality of gas has changed drastically in the past few years. Most gas is wet with hydrocarbons, water, and heavier contaminants that tend to condense if not handled properly. If a gas stream is contaminated with condensables, the sampling of that stream must be done in a manner that will ensure all of the components in the stream are introduced into the sample container as the composite. The sampling and handling of wet gas is extremely difficult under ideal conditions. There are no ideal conditions in the real world. The problems related to offshore operations and other wet gas systems, as well as the transportation of the sample, are additional problems that must be overcome if the analysis is to mean anything to the producer and gatherer. The sampling of wet gas systems is decidedly more difficult than sampling conventional dry gas systems. Wet gas systems were generally going to result in the measurement of one heating value at the inlet of the pipe and a drastic reduction in the heating value of the gas at the outlet end of the system. This is caused by the fallout or accumulation of the heavier products that, at the inlet, may be in the vapor state in the pipeline; hence, the high gravity and high BTU. But, in fact, because of pressure and temperature variances, these liquids condense and form a liquid that is actually running down the pipe as a stream or is accumulated in drips to be blown from the system. (author)

  16. An Ordered Probit Model Analysis of Transaction Costs and Market Participation by Small-Holder Cassava Farmers in South-Eastern Nigeria.

    OpenAIRE

    Okoye, B.C; Onyenweaku, C.E; Ukoha, O.O

    2010-01-01

    The Ordered Probit model analysis procedure was applied to determine the factors (related to fixed and variable transaction costs) influencing the decision to participate in cassava markets by a sample of 360 smallholder farmers in South-Eastern Nigeria. Participation decisions revealed that membership of cooperatives or social organizations, farming experience and marketing experience had a positive relationship with decision to be autarkic other than buyer and seller other than autarkic and...

  17. Compulsive buying and credit card misuse among credit card holders: the roles of self-esteem, materialism, impulsive buying and budget constraint

    OpenAIRE

    Nor Asiah Omar; Ruzita Abdul Rahim; Che Aniza Che Wel; Syed Shah Alam

    2014-01-01

    Purpose: This study aims to examine the factors that influence credit card misuse among working adults in Klang Valley, Malaysia. The relationship among self-esteem, materialism, impulsive buying, budget constraint, compulsive buying and credit card misuse are explored in this study. Design/methodology/approach: A total of 186 questionnaires was collected via convenience sampling from credit card users of working adults in Malaysia. A structural equation model that assesses the relationship b...

  18. Seroprevalence of highly pathogenic avian influenza H5 subtype clade 2.3.2 on ducks and muscouvy ducks in small holders farm

    Directory of Open Access Journals (Sweden)

    Eny Martindah

    2015-12-01

    Full Text Available Seroprevalence studies of HPAI H5 subtype in ducks and muscouvy duck in smallholders farm was carried out in Serang and Tangerang District, Banten Province. The study comprised a serological survey to define the distribution and prevalence of HPAI H5 subtype infection on ducks and muscouvy ducks as well as attempted isolation of the virus from these species. Unit of sample in each stage was randomly choosen by multy stage random sample. Blood samples were taken from ducks and muscouvy ducks that had never been vaccinated, purposively. Sera were tested using Haemaglutination Inhibition Test, antigen H5N1 (clade 2.3.2, while the cloaca and trachea swab samples was injected into specific pathogens free (SPF embryonated 9-11 days old, to isolate the virus. Results showed that H5 subtype virus could be isolated from tracheal swabs of ducks in the various age groups. The seroprevalence of H5 subtype virus in Banten Province was 25.5%, in which, 24.3% occured in ducks and in muscouvy duck in the rate of 1.2%, with titer HI positive was > 3log2. Based on species, seroprevalence level HPAI H5 subtype in ducks was 3-4 times higher than the level of seroprevalence of HPAI H5 subtype in muscouvy duck, which indicated that the H5 subtype virus more likely to circulate in the ducks flock than in muscouvy duck. This study noted that both muscouvy duck and ducks appeared to play a significant role in the epidemiology of the disease.

  19. Recommended protocols for sampling macrofungi

    Science.gov (United States)

    Gregory M. Mueller; John Paul Schmit; Sabine M. Hubndorf Leif Ryvarden; Thomas E. O' Dell; D. Jean Lodge; Patrick R. Leacock; Milagro Mata; Loengrin Umania; Qiuxin (Florence) Wu; Daniel L. Czederpiltz

    2004-01-01

    This chapter discusses several issues regarding reommended protocols for sampling macrofungi: Opportunistic sampling of macrofungi, sampling conspicuous macrofungi using fixed-size, sampling small Ascomycetes using microplots, and sampling a fixed number of downed logs.

  20. Nonuniform sampling by quantiles.

    Science.gov (United States)

    Craft, D Levi; Sonstrom, Reilly E; Rovnyak, Virginia G; Rovnyak, David

    2018-02-13

    A flexible strategy for choosing samples nonuniformly from a Nyquist grid using the concept of statistical quantiles is presented for broad classes of NMR experimentation. Quantile-directed scheduling is intuitive and flexible for any weighting function, promotes reproducibility and seed independence, and is generalizable to multiple dimensions. In brief, weighting functions are divided into regions of equal probability, which define the samples to be acquired. Quantile scheduling therefore achieves close adherence to a probability distribution function, thereby minimizing gaps for any given degree of subsampling of the Nyquist grid. A characteristic of quantile scheduling is that one-dimensional, weighted NUS schedules are deterministic, however higher dimensional schedules are similar within a user-specified jittering parameter. To develop unweighted sampling, we investigated the minimum jitter needed to disrupt subharmonic tracts, and show that this criterion can be met in many cases by jittering within 25-50% of the subharmonic gap. For nD-NUS, three supplemental components to choosing samples by quantiles are proposed in this work: (i) forcing the corner samples to ensure sampling to specified maximum values in indirect evolution times, (ii) providing an option to triangular backfill sampling schedules to promote dense/uniform tracts at the beginning of signal evolution periods, and (iii) providing an option to force the edges of nD-NUS schedules to be identical to the 1D quantiles. Quantile-directed scheduling meets the diverse needs of current NUS experimentation, but can also be used for future NUS implementations such as off-grid NUS and more. A computer program implementing these principles (a.k.a. QSched) in 1D- and 2D-NUS is available under the general public license. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. AND/OR Importance Sampling

    OpenAIRE

    Gogate, Vibhav; Dechter, Rina

    2012-01-01

    The paper introduces AND/OR importance sampling for probabilistic graphical models. In contrast to importance sampling, AND/OR importance sampling caches samples in the AND/OR space and then extracts a new sample mean from the stored samples. We prove that AND/OR importance sampling may have lower variance than importance sampling; thereby providing a theoretical justification for preferring it over importance sampling. Our empirical evaluation demonstrates that AND/OR importance sampling is ...

  2. Sampling polyhexamethylene guanidine aerosols using eosin Y-coated glass beads

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sang Hyun; Park, Seon Kyung; Kang, Hyun Joong; Kwon, Jung Hwan [Korea University, Seoul (Korea, Republic of); Lee, Kyu Hong [Korea Institute of Toxicology, Jeongeup (Korea, Republic of)

    2015-07-15

    Fatalities caused by the use of polyhexamethylene guanidine (PHMG), a general-purpose chemical germicide used as a humidifier disinfectant in Korea, have raised concerns about exposure to biocide aerosols in indoor environments. A sampler capable of accumulating PHMG from aqueous aerosols was developed as an alternative to low-volume air samplers. This sampler was prepared by placing glass beads coated with 2-(2,4,5,7-tetrabromo-6-oxido-3-oxo-3H-xanthen-9-yl)benzoate (Eosin Y) in a custom-made plastic holder. Passive sampling rates, measured in a bench-top exposure chamber at two different aqueous PHMG aerosol generation rates, were found to be independent of the experimental conditions. This suggests that the capacity of the sampler to accumulate the PHMG aerosol was sufficient for the sampling duration tested. However, the passive sampling rate was 7.6 × 10{sup −6} m{sup 3}/h for the sampler area of 22 cm{sup 2}. This rate is lower than the typical human breathing rate and inadequate for quantitative instrumental analyses at low concentrations in indoor air. A 30-fold enhancement of the sampling rate was achieved by forced convection using a commercial battery-operated fan at ≥2000 rpm. With this accelerated sampling rate, the sampler could be used to monitor time-integrated concentrations of PHMG aerosols in the air.

  3. Ethics and sample size.

    Science.gov (United States)

    Bacchetti, Peter; Wolf, Leslie E; Segal, Mark R; McCulloch, Charles E

    2005-01-15

    The belief is widespread that studies are unethical if their sample size is not large enough to ensure adequate power. The authors examine how sample size influences the balance that determines the ethical acceptability of a study: the balance between the burdens that participants accept and the clinical or scientific value that a study can be expected to produce. The average projected burden per participant remains constant as the sample size increases, but the projected study value does not increase as rapidly as the sample size if it is assumed to be proportional to power or inversely proportional to confidence interval width. This implies that the value per participant declines as the sample size increases and that smaller studies therefore have more favorable ratios of projected value to participant burden. The ethical treatment of study participants therefore does not require consideration of whether study power is less than the conventional goal of 80% or 90%. Lower power does not make a study unethical. The analysis addresses only ethical acceptability, not optimality; large studies may be desirable for other than ethical reasons.

  4. Thermal conduction in a composite circular cylinder: A new technique for thermal conductivity measurements of lunar core samples

    Science.gov (United States)

    Horai, K.; Winkler, J. L., Jr.; Keihm, S. J.; Langseth, M. G.; Fountain, J. A.; West, E. A.

    1980-01-01

    The core sample is heated from the outside at a known rate and the rise in temperature at the surface of the core tube is measured. Because the temperature at the surface, increasing with time, is a function of the thermal properties of both the core tube and the sample, the thermal properties of the sample can be estimated by comparing the measured temperature with the theory, provided that the thermal properties of the core tube are known. Thus it is not necessary to extract the sample from the core tube to make the measurements. Neither is it necessary to insert a heater, or temperature sensor, into the sample within the core tube, as would be required if another method were applied. The sample remains intact after the measurements. The temperature change in the sample can be kept to a minimum as long as the thermal conductivity determination is possible with a reasonable precision. If the radiative method of heat transfer is chosen, the core tube will only be in mechanical contact with the sample holder and a sensor attached to the core tube to measure the surface temperature, thereby greatly reducing the possibility of disturbing the sample.

  5. Interactive Sample Book (ISB)

    DEFF Research Database (Denmark)

    Heimdal, Elisabeth Jacobsen; Lenau, Torben Anker; Guglielmi, Michel

    2009-01-01

    supervisor Torben A. Lenau. Inspiration to use smart materials Interactive textiles are still quite an unknown phenomenon to many. It is thus often difficult to communicate what kind of potentials lie within these materials. This is why the ISB project was started, as a practice based research project...... and senses in relation to integrated decoration and function primarily to indoor applications. The result of the project will be a number of interactive textiles, to be gathered in an interactive sample book (ISB), in a similar way as the sample books of wallpapers one can take home from the shop and choose...... from. In other words, it is a kind of display material, which in a simple manner can illustrate how different techniques and smart materials work. The sample book should display a number of possibilities where sensor technology, smart materials and textiles are mixed to such an extent that the textile...

  6. Radioactive air sampling methods

    CERN Document Server

    Maiello, Mark L

    2010-01-01

    Although the field of radioactive air sampling has matured and evolved over decades, it has lacked a single resource that assimilates technical and background information on its many facets. Edited by experts and with contributions from top practitioners and researchers, Radioactive Air Sampling Methods provides authoritative guidance on measuring airborne radioactivity from industrial, research, and nuclear power operations, as well as naturally occuring radioactivity in the environment. Designed for industrial hygienists, air quality experts, and heath physicists, the book delves into the applied research advancing and transforming practice with improvements to measurement equipment, human dose modeling of inhaled radioactivity, and radiation safety regulations. To present a wide picture of the field, it covers the international and national standards that guide the quality of air sampling measurements and equipment. It discusses emergency response issues, including radioactive fallout and the assets used ...

  7. Strategic Sample Selection

    DEFF Research Database (Denmark)

    Di Tillio, Alfredo; Ottaviani, Marco; Sørensen, Peter Norman

    2017-01-01

    is double logconvex, as with normal noise. The results are applied to the analysis of strategic sample selection by a biased researcher and extended to the case of uncertain and unanticipated selection. Our theoretical analysis offers applied research a new angle on the problem of selection in empirical......What is the impact of sample selection on the inference payoff of an evaluator testing a simple hypothesis based on the outcome of a location experiment? We show that anticipated selection locally reduces noise dispersion and thus increases informativeness if and only if the noise distribution...

  8. Sample size for beginners.

    Science.gov (United States)

    Florey, C D

    1993-05-01

    The common failure to include an estimation of sample size in grant proposals imposes a major handicap on applicants, particularly for those proposing work in any aspect of research in the health services. Members of research committees need evidence that a study is of adequate size for there to be a reasonable chance of a clear answer at the end. A simple illustrated explanation of the concepts in determining sample size should encourage the faint hearted to pay more attention to this increasingly important aspect of grantsmanship.

  9. Quantum private data sampling

    Science.gov (United States)

    Fattal, David; Fiorentino, Marco; Beausoleil, Raymond G.

    2009-08-01

    We present a novel quantum communication protocol for "Private Data Sampling", where a player (Bob) obtains a random sample of limited size of a classical database, while the database owner (Alice) remains oblivious as to which bits were accessed. The protocol is efficient in the sense that the communication complexity per query scales at most linearly with the size of the database. It does not violate Lo's "no-go" theorem for one-sided twoparty secure computation, since a given joint input by Alice and Bob can result in randomly different protocol outcomes. After outlining the main security features of the protocol, we present our first experimental results.

  10. A cross sectional observational study to estimate herd level risk factors for Leptospira spp. serovars in small holder dairy cattle farms in southern Chile.

    Science.gov (United States)

    Salgado, Miguel; Otto, Barbara; Sandoval, Errol; Reinhardt, German; Boqvist, Sofia

    2014-06-06

    The south of Chile constitutes the main cattle milk producing area of the country. Regarding leptospirosis control in Chile, there is neither an official program nor an epidemiological characterization of smallholder dairy farms. This study was carried out to determine Leptospira seroprevalence and to evaluate risk factors associated with seropositivity at herd level in smallholder bovine dairy herds in southern Chile.A cross-sectional study was conducted, and a convenient sample of 1,537 apparently healthy dairy cows was included in the study. Individual blood samples were taken and examined for six selected reference Leptospira serovars by the Microscopic Agglutination Test (MAT). Of the included herds 75% (52/69) showed serological titers against one or more Leptospira serovar. Leptospira borgpetersenii serovar Hardjo was the serovar most frequently (81%) reported from animals with positive results. The variables considered risk factors for Leptospira seropositivity were calve natural breeding system, using a specific calving area and vaccination against Leptospira. Adult cows in contact with calves weaned, proved to be a protective factor against infection. Herds neglecting the management practices mentioned in this study could represent an important source of Leptospira infection for other herds in the same geographic area, as well as for other animal species.

  11. Request for wood samples

    NARCIS (Netherlands)

    NN,

    1977-01-01

    In recent years the wood collection at the Rijksherbarium was greatly expanded following a renewed interest in wood anatomy as an aid for solving classification problems. Staff members of the Rijksherbarium added to the collection by taking interesting wood samples with them from their expeditions

  12. Determination of Sample Size

    OpenAIRE

    Naing, Nyi Nyi

    2003-01-01

    There is a particular importance of determining a basic minimum required ‘n’ size of the sample to recognize a particular measurement of a particular population. This article has highlighted the determination of an appropriate size to estimate population parameters.

  13. Drafting Work Sample.

    Science.gov (United States)

    Shawsheen Valley Regional Vocational-Technical High School, Billerica, MA.

    This manual contains a work sample intended to assess a handicapped student's interest in and to screen interested students into a training program in basic mechanical drawing. (The course is based on the entry level of an assistant drafter.) Section 1 describes the assessment, correlates the work performed and worker traits required for…

  14. Optimal Sampling and Interpolation

    NARCIS (Netherlands)

    Shekhawat, Hanumant

    2012-01-01

    The main objective in this thesis is to design optimal samplers, downsamplers and interpolators (holds) which are required in signal processing. The sampled-data system theory is used to fulfill this objective in a generic setup. Signal processing, which includes signal transmission, storage and

  15. Compulsive buying and credit card misuse among credit card holders: The roles of self-esteem, materialism, impulsive buying and budget constraint

    Directory of Open Access Journals (Sweden)

    Nor Asiah Omar

    2014-02-01

    Full Text Available Purpose: This study aims to examine the factors that influence credit card misuse among working adults in Klang Valley, Malaysia. The relationship among self-esteem, materialism, impulsive buying, budget constraint, compulsive buying and credit card misuse are explored in this study. Design/methodology/approach: A total of 186 questionnaires was collected via convenience sampling from credit card users of working adults in Malaysia. A structural equation model that assesses the relationship between the proposed variables is tested using AMOS 20. Findings: The findings reveal that budget constraints, impulsive buying and materialism have a statistically significant influence on compulsive buying. In terms of credit card misuse, it is influenced negatively by self-esteem while positively by compulsive buying. Originality/value: Despite vast research on compulsive buying and credit card misuse, very few studies have examined it in the non-Western context.

  16. Biological Sampling Variability Study

    Energy Technology Data Exchange (ETDEWEB)

    Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-08

    There are many sources of variability that exist in the sample collection and analysis process. This paper addresses many, but not all, sources of variability. The main focus of this paper was to better understand and estimate variability due to differences between samplers. Variability between days was also studied, as well as random variability within each sampler. Experiments were performed using multiple surface materials (ceramic and stainless steel), multiple contaminant concentrations (10 spores and 100 spores), and with and without the presence of interfering material. All testing was done with sponge sticks using 10-inch by 10-inch coupons. Bacillus atrophaeus was used as the BA surrogate. Spores were deposited using wet deposition. Grime was coated on the coupons which were planned to include the interfering material (Section 3.3). Samples were prepared and analyzed at PNNL using CDC protocol (Section 3.4) and then cultured and counted. Five samplers were trained so that samples were taken using the same protocol. Each sampler randomly sampled eight coupons each day, four coupons with 10 spores deposited and four coupons with 100 spores deposited. Each day consisted of one material being tested. The clean samples (no interfering materials) were run first, followed by the dirty samples (coated with interfering material). There was a significant difference in recovery efficiency between the coupons with 10 spores deposited (mean of 48.9%) and those with 100 spores deposited (mean of 59.8%). There was no general significant difference between the clean and dirty (containing interfering material) coupons or between the two surface materials; however, there was a significant interaction between concentration amount and presence of interfering material. The recovery efficiency was close to the same for coupons with 10 spores deposited, but for the coupons with 100 spores deposited, the recovery efficiency for the dirty samples was significantly larger (65

  17. Tabletop magnetic resonance elastography for the measurement of viscoelastic parameters of small tissue samples

    Science.gov (United States)

    Ipek-Ugay, Selcan; Drießle, Toni; Ledwig, Michael; Guo, Jing; Hirsch, Sebastian; Sack, Ingolf; Braun, Jürgen

    2015-02-01

    We demonstrate the feasibility of low-cost tabletop MR elastography (MRE) for quantifying the complex shear modulus G∗ of small soft biological tissue samples as provided by pathologists. The MRE system was developed based on a tabletop MRI scanner equipped with a 0.5 T permanent magnet and a tissue sample holder mounted to a loudspeaker. A spin echo sequence was enhanced with motion-encoding gradients of 250 mT/m amplitude synchronized to acoustic vibration frequencies. Shear wave images suitable for elastography were acquired between vibration frequencies of 0.5 and 1 kHz in agarose, ultrasound gel, porcine liver, porcine skeletal muscle, and bovine heart with a spatial resolution of 234 μm pixel edge length. The measured frequency dependence of G∗ agreed well with previous work based on high-field MR systems. The ratio between loss and storage moduli was highest in liver and ultrasound gel, followed by muscle tissue and agarose gel while ultrasound gel and liver showed similarly low storage moduli compared to the other samples. The shear wave to noise ratio is an important imaging criteria for MRE and was about 4.2 times lower for the preliminary setup of the 0.5 T tabletop system compared to a 7 T animal scanner. In the future, the new tabletop MRE system may serve as a low cost device for preclinical research on the correlation of viscoelastic parameters with histopathology of biological samples.

  18. Sampling system and method

    Energy Technology Data Exchange (ETDEWEB)

    Decker, David L.; Lyles, Brad F.; Purcell, Richard G.; Hershey, Ronald Lee

    2017-03-07

    In one embodiment, the present disclosure provides an apparatus and method for supporting a tubing bundle during installation or removal. The apparatus includes a clamp for securing the tubing bundle to an external wireline. In various examples, the clamp is external to the tubing bundle or integral with the tubing bundle. According to one method, a tubing bundle and wireline are deployed together and the tubing bundle periodically secured to the wireline using a clamp. In another embodiment, the present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit. In a specific example, one or more clamps are used to connect the first and/or second conduits to an external wireline.

  19. Steered transition path sampling.

    Science.gov (United States)

    Guttenberg, Nicholas; Dinner, Aaron R; Weare, Jonathan

    2012-06-21

    We introduce a path sampling method for obtaining statistical properties of an arbitrary stochastic dynamics. The method works by decomposing a trajectory in time, estimating the probability of satisfying a progress constraint, modifying the dynamics based on that probability, and then reweighting to calculate averages. Because the progress constraint can be formulated in terms of occurrences of events within time intervals, the method is particularly well suited for controlling the sampling of currents of dynamic events. We demonstrate the method for calculating transition probabilities in barrier crossing problems and survival probabilities in strongly diffusive systems with absorbing states, which are difficult to treat by shooting. We discuss the relation of the algorithm to other methods.

  20. Digital Microfluidics Sample Analyzer

    Science.gov (United States)

    Pollack, Michael G.; Srinivasan, Vijay; Eckhardt, Allen; Paik, Philip Y.; Sudarsan, Arjun; Shenderov, Alex; Hua, Zhishan; Pamula, Vamsee K.

    2010-01-01

    Three innovations address the needs of the medical world with regard to microfluidic manipulation and testing of physiological samples in ways that can benefit point-of-care needs for patients such as premature infants, for which drawing of blood for continuous tests can be life-threatening in their own right, and for expedited results. A chip with sample injection elements, reservoirs (and waste), droplet formation structures, fluidic pathways, mixing areas, and optical detection sites, was fabricated to test the various components of the microfluidic platform, both individually and in integrated fashion. The droplet control system permits a user to control droplet microactuator system functions, such as droplet operations and detector operations. Also, the programming system allows a user to develop software routines for controlling droplet microactuator system functions, such as droplet operations and detector operations. A chip is incorporated into the system with a controller, a detector, input and output devices, and software. A novel filler fluid formulation is used for the transport of droplets with high protein concentrations. Novel assemblies for detection of photons from an on-chip droplet are present, as well as novel systems for conducting various assays, such as immunoassays and PCR (polymerase chain reaction). The lab-on-a-chip (a.k.a., lab-on-a-printed-circuit board) processes physiological samples and comprises a system for automated, multi-analyte measurements using sub-microliter samples of human serum. The invention also relates to a diagnostic chip and system including the chip that performs many of the routine operations of a central labbased chemistry analyzer, integrating, for example, colorimetric assays (e.g., for proteins), chemiluminescence/fluorescence assays (e.g., for enzymes, electrolytes, and gases), and/or conductometric assays (e.g., for hematocrit on plasma and whole blood) on a single chip platform.

  1. Simple and Versatile Turbidimetric Monitoring of Bacterial Growth in Liquid Cultures Using a Customized 3D Printed Culture Tube Holder and a Miniaturized Spectrophotometer: Application to Facultative and Strictly Anaerobic Bacteria.

    Science.gov (United States)

    Maia, Margarida R G; Marques, Sara; Cabrita, Ana R J; Wallace, R John; Thompson, Gertrude; Fonseca, António J M; Oliveira, Hugo M

    2016-01-01

    Here we introduce a novel strategy for turbidimetric monitoring of bacterial growth in liquid culture. The instrumentation comprises a light source, a customized 3D printed culture tube holder and a miniaturized spectrophotometer, connected through optical cables. Due to its small footprint and the possibility to operate with external light, bacterial growth was directly monitored from culture tubes in a simple and versatile fashion. This new portable measurement technique was used to monitor the growth of facultative (Escherichia coli ATCC/25922, and Staphylococcus aureus ATCC/29213) and strictly (Butyrivibrio fibrisolvens JW11, Butyrivibrio proteoclasticus P18, and Propionibacterium acnes DSMZ 1897) anaerobic bacteria. For E. coli and S. aureus, the growth rates calculated from normalized optical density values were compared with those ones obtained using a benchtop spectrophotometer without significant differences (P = 0.256). For the strictly anaerobic species, a high precision (relative standard deviation < 3.5%) was observed between replicates up to 48 h. Regarding its potential for customization, this manifold could accommodate further developments for customized turbidimetric monitoring, such as the use of light-emitting diodes as a light source or flow cells.

  2. Samples and Sampling Protocols for Scientific Investigations | Joel ...

    African Journals Online (AJOL)

    ... from sampling, through sample preparation, calibration to final measurement and reporting. This paper, therefore offers useful information on practical guidance on sampling protocols in line with best practice and international standards. Keywords: Sampling, sampling protocols, chain of custody, analysis, documentation ...

  3. Nåværende norske rutiner for innsamling av data innen kariesepidemiologi blant barn/unge – holder rutinene fortsatt mål?

    Directory of Open Access Journals (Sweden)

    Marit S. Skeie

    2012-05-01

    modern treatment philosophy of dental caries, reduced caries prevalence and if it contributes as a dental health promotion tool. As a secondary aim to critically evaluate the way caries data are reported in KOSTRA and how the data are presented as well as discuss reporting improvements. Findings show that the existing KOSTRA routines should be changed and the procedures updated in accordance with the modern philosophy of caries prevention and therapy. It is considered important to include carious lesions in enamel in the KOSTRA reports, and from an early age, to monitor caries development, for the optimal planning of the Public Dental Service for children and adolescents. Furthermore, KOSTRA should, if possible, change from an aggregated to an individual reporting level, using statistical random samples. The standard class intervals of frequency distributions should be revised to facilitate estimation of SIC in order to allow for changed caries experience in key age groups. Calibrated examiners should be used to carry out the registration in order to improve data quality in terms of reliability and validity.

  4. Repeated judgment sampling: Boundaries

    Directory of Open Access Journals (Sweden)

    Johannes Muller-Trede

    2011-06-01

    Full Text Available This paper investigates the boundaries of the recent result that eliciting more than one estimate from the same person and averaging these can lead to accuracy gains in judgment tasks. It first examines its generality, analysing whether the kind of question being asked has an effect on the size of potential gains. Experimental results show that the question type matters. Previous results reporting potential accuracy gains are reproduced for year-estimation questions, and extended to questions about percentage shares. On the other hand, no gains are found for general numerical questions. The second part of the paper tests repeated judgment sampling's practical applicability by asking judges to provide a third and final answer on the basis of their first two estimates. In an experiment, the majority of judges do not consistently average their first two answers. As a result, they do not realise the potential accuracy gains from averaging.

  5. Sampling the Hydrogen Atom

    Directory of Open Access Journals (Sweden)

    Graves N.

    2013-01-01

    Full Text Available A model is proposed for the hydrogen atom in which the electron is an objectively real particle orbiting at very near to light speed. The model is based on the postulate that certain velocity terms associated with orbiting bodies can be considered as being af- fected by relativity. This leads to a model for the atom in which the stable electron orbits are associated with orbital velocities where Gamma is n /α , leading to the idea that it is Gamma that is quantized and not angular momentum as in the Bohr and other models. The model provides a mechanism which leads to quantization of energy levels within the atom and also provides a simple mechanical explanation for the Fine Struc- ture Constant. The mechanism is closely associated with the Sampling theorem and the related phenomenon of aliasing developed in the mid-20th century by engineers at Bell labs.

  6. The guiding principles of the IRPA on the involvement of interested parties (Stake holders) in the management of radiation protection; Los principios orientativos de la IRPA sobre la implicacion de las partes interesadas (Stakeholders) en la gestion de la proteccion radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Arranz, L.; Carboneras, P.; Gallego, E.; Garcia, A.; Rodriguez, M.

    2011-07-01

    There is general consensus that the effective and well structured involvement of interested parties (stake holders) improves the quality of decision making and can achieve more effective and sustainable decisions that generate greater confidence among people and groups affected. The International Radiation Protection Association (IRPA) could not remain indifferent to this issue and has prepared a document of guiding principles for consideration, recommends to its members.

  7. Sample collection, biobanking, and analysis

    NARCIS (Netherlands)

    Ahsman, Maurice J.; Tibboel, Dick; Mathot, Ron A. A.; de Wildt, Saskia N.

    2011-01-01

    Pediatric pharmacokinetic studies require sampling of biofluids from neonates and children. Limitations on sampling frequency and sample volume complicate the design of these studies. In addition, strict guidelines, designed to guarantee patient safety, are in place. This chapter describes the

  8. Variable Sampling Mapping

    Science.gov (United States)

    Smith, Jeffrey, S.; Aronstein, David L.; Dean, Bruce H.; Lyon, Richard G.

    2012-01-01

    The performance of an optical system (for example, a telescope) is limited by the misalignments and manufacturing imperfections of the optical elements in the system. The impact of these misalignments and imperfections can be quantified by the phase variations imparted on light traveling through the system. Phase retrieval is a methodology for determining these variations. Phase retrieval uses images taken with the optical system and using a light source of known shape and characteristics. Unlike interferometric methods, which require an optical reference for comparison, and unlike Shack-Hartmann wavefront sensors that require special optical hardware at the optical system's exit pupil, phase retrieval is an in situ, image-based method for determining the phase variations of light at the system s exit pupil. Phase retrieval can be used both as an optical metrology tool (during fabrication of optical surfaces and assembly of optical systems) and as a sensor used in active, closed-loop control of an optical system, to optimize performance. One class of phase-retrieval algorithms is the iterative transform algorithm (ITA). ITAs estimate the phase variations by iteratively enforcing known constraints in the exit pupil and at the detector, determined from modeled or measured data. The Variable Sampling Mapping (VSM) technique is a new method for enforcing these constraints in ITAs. VSM is an open framework for addressing a wide range of issues that have previously been considered detrimental to high-accuracy phase retrieval, including undersampled images, broadband illumination, images taken at or near best focus, chromatic aberrations, jitter or vibration of the optical system or detector, and dead or noisy detector pixels. The VSM is a model-to-data mapping procedure. In VSM, fully sampled electric fields at multiple wavelengths are modeled inside the phase-retrieval algorithm, and then these fields are mapped to intensities on the light detector, using the properties

  9. Sample size estimation and sampling techniques for selecting a representative sample

    OpenAIRE

    Aamir Omair

    2014-01-01

    Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect ...

  10. Two-Step Sequential Sampling

    NARCIS (Netherlands)

    Moors, J.J.A.; Strijbosch, L.W.G.

    2000-01-01

    Deciding upon the optimal sample size in advance is a difficult problem in general. Often, the investigator regrets not having drawn a larger sample; in many cases additional observations are done. This implies that the actual sample size is no longer deterministic; hence, even if all sample

  11. Jenis Sample: Keuntungan dan Kerugiannya

    OpenAIRE

    Suprapto, Agus

    1994-01-01

    Sample is a part of a population that are used in a study for purposes of making estimation about the nature of the total population that is obtained with sampling technic. Sampling technic is more adventagous than cencus because it can reduce cost, time, and it can gather deeper information and more accurate data. It is useful to distinguish two major types of sampling technics. First, Prob bility sampling i.e. simple random sampling. Second, Non Probability sampling i.e. systematic sam­plin...

  12. Sample design for Understanding Society

    OpenAIRE

    Lynn, Peter

    2009-01-01

    This paper describes the design of the sample for “Understanding Society†. The sample consists of five components. The largest component is a newly-selected general population sample. The other four components are an ethnic minority ‘boost’ sample, a general population comparison sample, the ex-BHPS (British Household Panel Survey) sample, and the innovation panel sample. For each component, the paper outlines the design and explains the rationale behind the main features of the desig...

  13. Description of CBETA magnet tuning wire holders

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, S. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-07-19

    A non-­magnetic insert will be placed directly inside the permanent magnet blocks in every CBETA Halbach magnet in order to hold a set of iron “tuning wires”. These wires have various lengths around the perimeter of the aperture in order to cancel multipole field errors from the permanent magnet blocks.

  14. Thermistor holder for skin-temperature measurements

    Science.gov (United States)

    Greenleaf, J. E.; Williams, B. A.

    1974-01-01

    Sensing head of thermistor probe is supported in center area of plastic ring which has tabs so that it can be anchored in place by rubber bands or adhesive tapes. Device attaches probes to human subjects practically, reliably, and without affecting characteristics of skin segment being measured.

  15. Basic design of sample container for transport of extraterrestrial samples

    Science.gov (United States)

    Dirri, F.; Longobardo, A.; Palomba, E.; Hutzler, A.; Ferrière, L.

    2017-09-01

    The aim of this work is to provide, in the framework of the EURO-CARES (European Curation of Astromaterials Returned from Exploration of Space) project, a technical overview based on the sample container used in previous sample return missions (e.g., Hayabusa1, Stardust, etc.) and to define a basic design of a sample container aimed at transporting the extraterrestrial returned samples within a Sample Curation Facility (SCF) or from a SCF to another laboratory (and vice versa). The sample container structure and the transportation criticalities (such as contamination and mechanical stress) are discussed in detail in each scenario.

  16. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Haydn [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of); Marco Parra, Lue-Meru, E-mail: luemerumarco@yahoo.e [Universidad Centroccidental Lisandro Alvarado, Dpto. Quimica y Suelos, Decanato de Agronomia, Tarabana, Cabudare, Edo.Lara (Venezuela, Bolivarian Republic of); Bennun, Leonardo [Universidad de Concepcion, Concepcion (Chile); Greaves, Eduardo D. [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of)

    2010-06-15

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-K{alpha} and Co-K{alpha} lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 {mu}gL{sup -1}. The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  17. Low-Z polymer sample supports for fixed-target serial femtosecond X-ray crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Feld, Geoffrey K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); National Institute of Environmental Health Science, Research Triangle Park, NC (United States); Heymann, Michael [Brandeis Univ., Waltham, MA (United States); Univ. of Hamburg and DESY, Hamburg (Germany); Benner, W. Henry [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pardini, Tommaso [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tsai, Ching -Ju [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Boutet, Sebastien [SLAC National Accelerator Lab., Menlo Park, CA (United States); Coleman, Matthew A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hunter, Mark S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); SLAC National Accelerator Lab., Menlo Park, CA (United States); Li, Xiaodan [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Messerschmidt, Marc [SLAC National Accelerator Lab., Menlo Park, CA (United States); BioXFEL Science and Technology Center, Buffalo, NY (United States); Opathalage, Achini [Brandeis Univ., Waltham, MA (United States); Pedrini, Bill [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Williams, Garth J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Krantz, Bryan A. [Univ. of California, Berkeley, CA (United States); Fraden, Seth [Brandeis Univ., Waltham, MA (United States); Hau-Riege, Stefan [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Evans, James E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Segelke, Brent W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Frank, Matthias [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-06-27

    X-ray free-electron lasers (XFELs) offer a new avenue to the structural probing of complex materials, including biomolecules. Delivery of precious sample to the XFEL beam is a key consideration, as the sample of interest must be serially replaced after each destructive pulse. The fixed-target approach to sample delivery involves depositing samples on a thin-film support and subsequent serial introduction via a translating stage. Some classes of biological materials, including two-dimensional protein crystals, must be introduced on fixed-target supports, as they require a flat surface to prevent sample wrinkling. A series of wafer and transmission electron microscopy (TEM)-style grid supports constructed of low-Z plastic have been custom-designed and produced. Aluminium TEM grid holders were engineered, capable of delivering up to 20 different conventional or plastic TEM grids using fixed-target stages available at the Linac Coherent Light Source (LCLS). As proof-of-principle, X-ray diffraction has been demonstrated from two-dimensional crystals of bacteriorhodopsin and three-dimensional crystals of anthrax toxin protective antigen mounted on these supports at the LCLS. In conclusion, the benefits and limitations of these low-Z fixed-target supports are discussed; it is the authors' belief that they represent a viable and efficient alternative to previously reported fixed-target supports for conducting diffraction studies with XFELs.

  18. Coordination of Conditional Poisson Samples

    Directory of Open Access Journals (Sweden)

    Grafström Anton

    2015-12-01

    Full Text Available Sample coordination seeks to maximize or to minimize the overlap of two or more samples. The former is known as positive coordination, and the latter as negative coordination. Positive coordination is mainly used for estimation purposes and to reduce data collection costs. Negative coordination is mainly performed to diminish the response burden of the sampled units. Poisson sampling design with permanent random numbers provides an optimum coordination degree of two or more samples. The size of a Poisson sample is, however, random. Conditional Poisson (CP sampling is a modification of the classical Poisson sampling that produces a fixed-size πps sample. We introduce two methods to coordinate Conditional Poisson samples over time or simultaneously. The first one uses permanent random numbers and the list-sequential implementation of CP sampling. The second method uses a CP sample in the first selection and provides an approximate one in the second selection because the prescribed inclusion probabilities are not respected exactly. The methods are evaluated using the size of the expected sample overlap, and are compared with their competitors using Monte Carlo simulation. The new methods provide a good coordination degree of two samples, close to the performance of Poisson sampling with permanent random numbers.

  19. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  20. Sample Acquisition for Materials in Planetary Exploration (SAMPLE) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — ORBITEC proposes to analyze, design, and develop a device for autonomous lunar surface/subsurface sampling and processing applications. The Sample Acquisition for...

  1. Sampling and chemical analysis in environmental samples around Nuclear Power Plants and some environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2002-12-15

    Twelve kinds of environmental samples such as soil, seawater, underground water, etc. around Nuclear Power Plants(NPPs) were collected. Tritium chemical analysis was tried for the samples of rain water, pine-needle, air, seawater, underground water, chinese cabbage, a grain of rice and milk sampled around NPPs, and surface seawater and rain water sampled over the country. Strontium in the soil that sere sampled at 60 point of district in Korea were analyzed. Tritium were sampled at 60 point of district in Korea were analyzed. Tritium were analyzed in 21 samples of surface seawater around the Korea peninsular that were supplied from KFRDI(National Fisheries Research and Development Institute). Sampling and chemical analysis environmental samples around Kori, Woolsung, Youngkwang, Wooljin Npps and Taeduk science town for tritium and strontium analysis was managed according to plans. Succeed to KINS after all samples were tried.

  2. A Note on Information-Directed Sampling and Thompson Sampling

    OpenAIRE

    Zhou, Li

    2015-01-01

    This note introduce three Bayesian style Multi-armed bandit algorithms: Information-directed sampling, Thompson Sampling and Generalized Thompson Sampling. The goal is to give an intuitive explanation for these three algorithms and their regret bounds, and provide some derivations that are omitted in the original papers.

  3. Metadata, Identifiers, and Physical Samples

    Science.gov (United States)

    Arctur, D. K.; Lenhardt, W. C.; Hills, D. J.; Jenkyns, R.; Stroker, K. J.; Todd, N. S.; Dassie, E. P.; Bowring, J. F.

    2016-12-01

    Physical samples are integral to much of the research conducted by geoscientists. The samples used in this research are often obtained at significant cost and represent an important investment for future research. However, making information about samples - whether considered data or metadata - available for researchers to enable discovery is difficult: a number of key elements related to samples are difficult to characterize in common ways, such as classification, location, sample type, sampling method, repository information, subsample distribution, and instrumentation, because these differ from one domain to the next. Unifying these elements or developing metadata crosswalks is needed. The iSamples (Internet of Samples) NSF-funded Research Coordination Network (RCN) is investigating ways to develop these types of interoperability and crosswalks. Within the iSamples RCN, one of its working groups, WG1, has focused on the metadata related to physical samples. This includes identifying existing metadata standards and systems, and how they might interoperate with the International Geo Sample Number (IGSN) schema (schema.igsn.org) in order to help inform leading practices for metadata. For example, we are examining lifecycle metadata beyond the IGSN `birth certificate.' As a first step, this working group is developing a list of relevant standards and comparing their various attributes. In addition, the working group is looking toward technical solutions to facilitate developing a linked set of registries to build the web of samples. Finally, the group is also developing a comparison of sample identifiers and locators. This paper will provide an overview and comparison of the standards identified thus far, as well as an update on the technical solutions examined for integration. We will discuss how various sample identifiers might work in complementary fashion with the IGSN to more completely describe samples, facilitate retrieval of contextual information, and

  4. New prior sampling methods for nested sampling - Development and testing

    Science.gov (United States)

    Stokes, Barrie; Tuyl, Frank; Hudson, Irene

    2017-06-01

    Nested Sampling is a powerful algorithm for fitting models to data in the Bayesian setting, introduced by Skilling [1]. The nested sampling algorithm proceeds by carrying out a series of compressive steps, involving successively nested iso-likelihood boundaries, starting with the full prior distribution of the problem parameters. The "central problem" of nested sampling is to draw at each step a sample from the prior distribution whose likelihood is greater than the current likelihood threshold, i.e., a sample falling inside the current likelihood-restricted region. For both flat and informative priors this ultimately requires uniform sampling restricted to the likelihood-restricted region. We present two new methods of carrying out this sampling step, and illustrate their use with the lighthouse problem [2], a bivariate likelihood used by Gregory [3] and a trivariate Gaussian mixture likelihood. All the algorithm development and testing reported here has been done with Mathematica® [4].

  5. Public Use Microdata Samples (PUMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — Public Use Microdata Samples (PUMS) are computer-accessible files containing records for a sample of housing units, with information on the characteristics of each...

  6. Graph Sampling for Visual Analytics

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Fangyan; Zhang, Song; Chung Wong, Pak

    2017-07-01

    Effectively visualizing large graphs and capturing the statistical properties are two challenging tasks. To aid in these two tasks, many sampling approaches for graph simplification have been proposed, falling into three categories: node sampling, edge sampling, and traversal-based sampling. It is still unknown which approach is the best. We evaluate commonly used graph sampling methods through a combined visual and statistical comparison of graphs sampled at various rates. We conduct our evaluation on three graph models: random graphs, small-world graphs, and scale-free graphs. Initial results indicate that the effectiveness of a sampling method is dependent on the graph model, the size of the graph, and the desired statistical property. This benchmark study can be used as a guideline in choosing the appropriate method for a particular graph sampling task, and the results presented can be incorporated into graph visualization and analysis tools.

  7. Treat Medication Samples with Respect

    Science.gov (United States)

    Home Support ISMP Newsletters Webinars Report Errors Educational Store Consulting FAQ Tools About Us Contact Us Treat Medication Samples with Respect A physician may give you samples of a particular medication at the time of your office or clinic visit. ...

  8. Representative mass reduction in sampling

    DEFF Research Database (Denmark)

    Petersen, Lars; Esbensen, Harry Kim; Dahl, Casper Kierulf

    2004-01-01

    dividers, the Boerner Divider, the ??spoon method??, alternate/fractional shoveling and grab sampling. Only devices based on riffle splitting principles (static or rotational) passes the ultimate representativity test (with minor, but significant relative differences). Grab sampling, the overwhelmingly...... always be representative in the full Theory of Sampling (TOS) sense. This survey also allows empirical verification of the merits of the famous ??Gy?s formula?? for order-of-magnitude estimation of the Fundamental Sampling Error (FSE)....

  9. The rise of survey sampling

    NARCIS (Netherlands)

    Bethlehem, J.

    2009-01-01

    This paper is about the history of survey sampling. It describes how sampling became an accepted scientific method. From the first ideas in 1895 it took some 50 years before the principles of probability sampling were widely accepted. This papers has a focus on developments in official statistics in

  10. Sample inhomogeneity in PIXE analysis

    Science.gov (United States)

    Kajfosz, J.; Szymczyk, S.; Kornaś, G.

    1984-04-01

    The influence of sample inhomogeneity on the precision of analytical results obtained by PIXE was investigated. A simple method for the determination of sample inhomogeneity is proposed and its applicability is shown on a series of examples. Differences in the distribution of individual elements in samples were observed.

  11. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  12. Mars Sample Quarantine Protocol Workshop

    Science.gov (United States)

    DeVincenzi, Donald L. (Editor); Bagby, John (Editor); Race, Margaret (Editor); Rummel, John (Editor)

    1999-01-01

    The Mars Sample Quarantine Protocol (QP) Workshop was convened to deal with three specific aspects of the initial handling of a returned Mars sample: 1) biocontainment, to prevent uncontrolled release of sample material into the terrestrial environment; 2) life detection, to examine the sample for evidence of live organisms; and 3) biohazard testing, to determine if the sample poses any threat to terrestrial life forms and the Earth's biosphere. During the first part of the Workshop, several tutorials were presented on topics related to the workshop in order to give all participants a common basis in the technical areas necessary to achieve the objectives of the Workshop.

  13. Sample processing device and method

    DEFF Research Database (Denmark)

    2011-01-01

    A sample processing device is disclosed, which sample processing device comprises a first substrate and a second substrate, where the first substrate has a first surface comprising two area types, a first area type with a first contact angle with water and a second area type with a second contact...... a sample liquid comprising the sample and the first preparation system is adapted to receive a receiving liquid. In a particular embodiment, a magnetic sample transport component, such as a permanent magnet or an electromagnet, is arranged to move magnetic beads in between the first and second substrates....

  14. Improve natural gas sampling techniques

    Energy Technology Data Exchange (ETDEWEB)

    Jiskoot, R.J.J. (Jiskoot Autocontrol, Kent (United Kingdom))

    1994-02-01

    Accurate and reliable sampling systems are imperative when confirming natural gas' commercial value. Buyers and sellers need accurate hydrocarbon-composition information to conduct fair sale transactions. Because of poor sample extraction, preparation or analysis can invalidate the sale, more attention should be directed toward improving representative sampling. Consider all sampling components, i.e., gas types, line pressure and temperature, equipment maintenance and service needs, etc. The paper discusses gas sampling, design considerations (location, probe type, extraction devices, controller, and receivers), operating requirements, and system integration.

  15. Rotary Percussive Sample Acquisition Tool

    Science.gov (United States)

    Klein, K.; Badescu, M.; Haddad, N.; Shiraishi, L.; Walkemeyer, P.

    2012-01-01

    As part of a potential Mars Sample Return campaign NASA is studying a sample caching mission to Mars, with a possible 2018 launch opportunity. As such, a Sample Acquisition Tool (SAT) has been developed in support of the Integrated Mars Sample Acquisition and Handling (IMSAH) architecture as it relates to the proposed Mars Sample Return (MSR) campaign. The tool allows for core generation and capture directly into a sample tube. In doing so, the sample tube becomes the fundamental handling element within the IMSAH sample chain reducing the risk associated with sample contamination as well as the need to handle a sample of unknown geometry. The tool's functionality was verified utilizing a proposed rock test suite that encompasses a series of rock types that have been utilized in the past to qualify Martian surface sampling hardware. The corresponding results have shown the tool can effectively generate, fracture, and capture rock cores while maintaining torque margins of no less than 50% with an average power consumption of no greater than 90W and a tool mass of less than 6kg.

  16. Manual versus automated blood sampling

    DEFF Research Database (Denmark)

    Teilmann, A C; Kalliokoski, Otto; Sørensen, Dorte B

    2014-01-01

    Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters......, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal...... corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters...

  17. Pierre Gy's sampling theory and sampling practice heterogeneity, sampling correctness, and statistical process control

    CERN Document Server

    Pitard, Francis F

    1993-01-01

    Pierre Gy's Sampling Theory and Sampling Practice, Second Edition is a concise, step-by-step guide for process variability management and methods. Updated and expanded, this new edition provides a comprehensive study of heterogeneity, covering the basic principles of sampling theory and its various applications. It presents many practical examples to allow readers to select appropriate sampling protocols and assess the validity of sampling protocols from others. The variability of dynamic process streams using variography is discussed to help bridge sampling theory with statistical process control. Many descriptions of good sampling devices, as well as descriptions of poor ones, are featured to educate readers on what to look for when purchasing sampling systems. The book uses its accessible, tutorial style to focus on professional selection and use of methods. The book will be a valuable guide for mineral processing engineers; metallurgists; geologists; miners; chemists; environmental scientists; and practit...

  18. Sampling designs dependent on sample parameters of auxiliary variables

    CERN Document Server

    Wywiał, Janusz L

    2015-01-01

    The book offers a valuable resource for students and statisticians whose work involves survey sampling. An estimation of the population parameters in finite and fixed populations assisted by auxiliary variables is considered. New sampling designs dependent on moments or quantiles of auxiliary variables are presented on the background of the classical methods. Accuracies of the estimators based on original sampling design are compared with classical estimation procedures. Specific conditional sampling designs are applied to problems of small area estimation as well as to estimation of quantiles of variables under study. .

  19. Comet coma sample return instrument

    Science.gov (United States)

    Albee, A. L.; Brownlee, Don E.; Burnett, Donald S.; Tsou, Peter; Uesugi, K. T.

    1994-01-01

    The sample collection technology and instrument concept for the Sample of Comet Coma Earth Return Mission (SOCCER) are described. The scientific goals of this Flyby Sample Return are to return to coma dust and volatile samples from a known comet source, which will permit accurate elemental and isotopic measurements for thousands of individual solid particles and volatiles, detailed analysis of the dust structure, morphology, and mineralogy of the intact samples, and identification of the biogenic elements or compounds in the solid and volatile samples. Having these intact samples, morphologic, petrographic, and phase structural features can be determined. Information on dust particle size, shape, and density can be ascertained by analyzing penetration holes and tracks in the capture medium. Time and spatial data of dust capture will provide understanding of the flux dynamics of the coma and the jets. Additional information will include the identification of cosmic ray tracks in the cometary grains, which can provide a particle's process history and perhaps even the age of the comet. The measurements will be made with the same equipment used for studying micrometeorites for decades past; hence, the results can be directly compared without extrapolation or modification. The data will provide a powerful and direct technique for comparing the cometary samples with all known types of meteorites and interplanetary dust. This sample collection system will provide the first sample return from a specifically identified primitive body and will allow, for the first time, a direct method of matching meteoritic materials captured on Earth with known parent bodies.

  20. Optimization of sampling parameters for standardized exhaled breath sampling.

    Science.gov (United States)

    Doran, Sophie; Romano, Andrea; Hanna, George B

    2017-09-05

    The lack of standardization of breath sampling is a major contributing factor to the poor repeatability of results and hence represents a barrier to the adoption of breath tests in clinical practice. On-line and bag breath sampling have advantages but do not suit multicentre clinical studies whereas storage and robust transport are essential for the conduct of wide-scale studies. Several devices have been developed to control sampling parameters and to concentrate volatile organic compounds (VOCs) onto thermal desorption (TD) tubes and subsequently transport those tubes for laboratory analysis. We conducted three experiments to investigate (i) the fraction of breath sampled (whole vs. lower expiratory exhaled breath); (ii) breath sample volume (125, 250, 500 and 1000ml) and (iii) breath sample flow rate (400, 200, 100 and 50 ml/min). The target VOCs were acetone and potential volatile biomarkers for oesophago-gastric cancer belonging to the aldehyde, fatty acids and phenol chemical classes. We also examined the collection execution time and the impact of environmental contamination. The experiments showed that the use of exhaled breath-sampling devices requires the selection of optimum sampling parameters. The increase in sample volume has improved the levels of VOCs detected. However, the influence of the fraction of exhaled breath and the flow rate depends on the target VOCs measured. The concentration of potential volatile biomarkers for oesophago-gastric cancer was not significantly different between the whole and lower airway exhaled breath. While the recovery of phenols and acetone from TD tubes was lower when breath sampling was performed at a higher flow rate, other VOCs were not affected. A dedicated 'clean air supply' overcomes the contamination from ambient air, but the breath collection device itself can be a source of contaminants. In clinical studies using VOCs to diagnose gastro-oesophageal cancer, the optimum parameters are 500mls sample volume

  1. Influence of sampling depth and post-sampling analysis time

    African Journals Online (AJOL)

    Paradise is released directly to the ocean at this point. ... cooled (0ºC - 0.2ºC) plastic bottle, sealed and labelled in the field. During mussel sampling, 10 -12 animals (sufficient to yield. 150-250 g of soft tissue), were taken from each shellfish stock sample, sealed in cool sterile plastic bags and kept in plastic containers.

  2. Quantum sampling problems, BosonSampling and quantum supremacy

    Science.gov (United States)

    Lund, A. P.; Bremner, Michael J.; Ralph, T. C.

    2017-04-01

    There is a large body of evidence for the potential of greater computational power using information carriers that are quantum mechanical over those governed by the laws of classical mechanics. But the question of the exact nature of the power contributed by quantum mechanics remains only partially answered. Furthermore, there exists doubt over the practicality of achieving a large enough quantum computation that definitively demonstrates quantum supremacy. Recently the study of computational problems that produce samples from probability distributions has added to both our understanding of the power of quantum algorithms and lowered the requirements for demonstration of fast quantum algorithms. The proposed quantum sampling problems do not require a quantum computer capable of universal operations and also permit physically realistic errors in their operation. This is an encouraging step towards an experimental demonstration of quantum algorithmic supremacy. In this paper, we will review sampling problems and the arguments that have been used to deduce when sampling problems are hard for classical computers to simulate. Two classes of quantum sampling problems that demonstrate the supremacy of quantum algorithms are BosonSampling and Instantaneous Quantum Polynomial-time Sampling. We will present the details of these classes and recent experimental progress towards demonstrating quantum supremacy in BosonSampling.

  3. Acceptance sampling using judgmental and randomly selected samples

    Energy Technology Data Exchange (ETDEWEB)

    Sego, Landon H.; Shulman, Stanley A.; Anderson, Kevin K.; Wilson, John E.; Pulsipher, Brent A.; Sieber, W. Karl

    2010-09-01

    We present a Bayesian model for acceptance sampling where the population consists of two groups, each with different levels of risk of containing unacceptable items. Expert opinion, or judgment, may be required to distinguish between the high and low-risk groups. Hence, high-risk items are likely to be identifed (and sampled) using expert judgment, while the remaining low-risk items are sampled randomly. We focus on the situation where all observed samples must be acceptable. Consequently, the objective of the statistical inference is to quantify the probability that a large percentage of the unsampled items in the population are also acceptable. We demonstrate that traditional (frequentist) acceptance sampling and simpler Bayesian formulations of the problem are essentially special cases of the proposed model. We explore the properties of the model in detail, and discuss the conditions necessary to ensure that required samples sizes are non-decreasing function of the population size. The method is applicable to a variety of acceptance sampling problems, and, in particular, to environmental sampling where the objective is to demonstrate the safety of reoccupying a remediated facility that has been contaminated with a lethal agent.

  4. Gravimetric dust sampling for control purposes and occupational dust sampling.

    CSIR Research Space (South Africa)

    Unsted, AD

    1997-02-01

    Full Text Available Prior to the introduction of gravimetric dust sampling, konimeters had been used for dust sampling, which was largely for control purposes. Whether or not absolute results were achievable was not an issue since relative results were used to evaluate...

  5. Burnout in a sample of primary school teachers in the city of Copiapó

    Directory of Open Access Journals (Sweden)

    Ricardo Jorquera Gutiérrez

    2014-11-01

    Full Text Available The present investigation sought to establish a relationship between burnout and a number of demographic and organizational variables. The sample consisted of 191 primary school teachers of municipal, subsidized and private educational institutions of Copiapó. The Maslach Burnout Inventory (MBI and the Cuestionario de Evaluación del Sindrome de Quemarse en el Trabajo (CESQT were used as tools to gather information from burnout levels presented by teachers. Two of them demonstrated an adequate reliability and concurrent validity. The results show a statistically significant relationship between absenteeism variable and all dimensions of burnout as measured by both instruments. No statistically significant differences between variables MBI and CESQT compared by sex, type of contract and income level were observed. When comparing the different dimensions of burnout by type of holder, statistically significant differences were detected in all of them. The results favor the private schools, showing the worst results in municipal schools. Alongside this, a negative correlation between levels of emotional exhaustion and psychological wear developed by teams of teachers and the results of the tests SIMCE [Sistema de Medición de la Calidad de la Educación] for second and fourth grade is observed.

  6. Sampling problems in twin research.

    Science.gov (United States)

    Torgersen, S

    1987-01-01

    Sampling problems related to twin problems may be of at least three kinds: small samples, self-selection and unrepresentative ascertainment. The article mostly discusses the third type of sample problem. Data from a nationwide Norwegian twin study show that the results of twin studies will be quite different depending upon the ascertainment procedure. According to both the ICD-9 as well as the DSM-III classification system, only samples ascertained from mental hospitals treating severe cases are able to demonstrate hereditary factors of any strength.

  7. A simple design for microwave assisted digestion vessel with low reagent consumption suitable for food and environmental samples

    Science.gov (United States)

    Gholami, Mehrdad; Behkami, Shima; Zain, Sharifuddin Md.; Bakirdere, Sezgin

    2016-11-01

    The objective of this work is to prepare a cost-effective, low reagent consumption and high performance polytetrafluoroethylene (PTFE) vessel that is capable to work in domestic microwave for digesting food and environmental samples. The designed vessel has a relatively thicker wall compared to that of commercial vessels. In this design, eight vessels are placed in an acrylonitrile butadiene styrene (ABS) holder to keep them safe and stable. This vessel needs only 2.0 mL of HNO3 and 1.0 mL H2O2 to digest 100 mg of biological sample. The performance of this design is then evaluated with an ICP-MS instrument in the analysis of the several NIST standard reference material of milk 1849a, rice flour 1568b, spinach leave 1570a and Peach Leaves 1547 in a domestic microwave oven with inverter technology. Outstanding agreement to (SRM) values are observed by using the suggested power to time microwave program, which simulates the reflux action occurring in this closed vessel. Taking into account the high cost of commercial microwave vessels and the volume of chemicals needed for various experiments (8-10 mL), this simple vessel is cost effective and suitable for digesting food and environmental samples.

  8. Paper-based analytical device for sampling, on-site preconcentration and detection of ppb lead in water.

    Science.gov (United States)

    Satarpai, Thiphol; Shiowatana, Juwadee; Siripinyanond, Atitaya

    2016-07-01

    A simple and cost effectiveness procedure based on a paper based analytical device (PAD) for sampling, on-site preconcentration and determination of Pb(II) in water samples was developed. The inkjet printing method was used for patterning of PAD. Colorimetric assay was developed on a PAD for Pb(II) detection in µgL(-1) level. This µgL(-1) level detection limit was achieved by in situ- and on-site preconcentration of Pb(II) onto adsorption filter paper disc with a home-made holder before color development. Water sample was loaded onto a circular filter paper coated with zirconium silicate in 3% sodium carboxymethylcellulose for Pb(II) preconcentration. Subsequently, sodium rhodizonate in tartrate buffer solution (pH 2.8) was used as colorimetric reagent for direct Pb(II) detection on a PAD. Detection was achieved by measuring the pink color and recorded by scanner or digital camera. ImageJ software was used for measuring grey scale values. The calibration curve was linear in the range of 10µgL(-1) and 100µgL(-1), with a detection limit of 10µgL(-1). The developed method was successfully applied to the determination of Pb(II) in drinking water, tap water and surface water near electronic waste storage and the results were compared with those by graphite furnace atomic absorption spectroscopy (GF-AAS) with good agreement. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Neonatal blood gas sampling methods

    African Journals Online (AJOL)

    Blood gas sampling is part of everyday practice in the care of babies admitted to the neonatal intensive care unit, particularly for those receiving respiratory support. There is little published guidance that systematically evaluates the different methods of neonatal blood gas sampling, where each method has its individual ...

  10. Learning to Reason from Samples

    Science.gov (United States)

    Ben-Zvi, Dani; Bakker, Arthur; Makar, Katie

    2015-01-01

    The goal of this article is to introduce the topic of "learning to reason from samples," which is the focus of this special issue of "Educational Studies in Mathematics" on "statistical reasoning." Samples are data sets, taken from some wider universe (e.g., a population or a process) using a particular procedure…

  11. Learning to reason from samples

    NARCIS (Netherlands)

    Ben-Zvi, Dani; Bakker, Arthur; Makar, Katie

    2015-01-01

    The goal of this article is to introduce the topic of learning to reason from samples, which is the focus of this special issue of Educational Studies in Mathematics on statistical reasoning. Samples are data sets, taken from some wider universe (e.g., a population or a process) using a particular

  12. Simulated Sampling of Estuary Plankton

    Science.gov (United States)

    Fortner, Rosanne W.; Jenkins, Deborah Bainer

    2009-01-01

    To find out about the microscopic life in the valuable estuary environment, it is usually necessary to be near the water. This dry lab offers an alternative, using authentic data and a simulation of plankton sampling. From the types of organisms found in the sample, middle school students can infer relationships in the biological and physical…

  13. Sample-whitened matched filters

    DEFF Research Database (Denmark)

    Andersen, Ib

    1973-01-01

    A sample-whitened matched filter (SWMF) for a channel with intersymbol interference and additive white Gaussian noise is defined as a linear filter with the properties that its output samples are a sufficient statistic for the MAP estimation of the transmitted sequence and have uncorrelated noise...

  14. Sampling by Fluidics and Microfluidics

    Directory of Open Access Journals (Sweden)

    V. Tesař

    2002-01-01

    Full Text Available Selecting one from several available fluid samples is a procedure often performed especially in chemical engineering. It is usually done by an array of valves sequentially opened and closed. Not generally known is an advantageous alternative: fluidic sampling units without moving parts. In the absence of complete pipe closure, cross-contamination between samples cannot be ruled out. This is eliminated by arranging for small protective flows that clear the cavities and remove any contaminated fluid. Although this complicates the overall circuit layout, fluidic sampling units with these "guard" flows were successfully built and tested. Recent interest in microchemistry leads to additional problems due very low operating Reynolds numbers. This necessitated the design of microfluidic sampling units based on new operating principles.

  15. Hermetic Seal Designs for Sample Return Sample Tubes

    Science.gov (United States)

    Younse, Paulo J.

    2013-01-01

    Prototypes have been developed of potential hermetic sample sealing techniques for encapsulating samples in a ˜1-cm-diameter thin-walled sample tube that are compatible with IMSAH (Integrated Mars Sample Acquisition and Handling) architecture. Techniques include a heat-activated, finned, shape memory alloy plug; a contracting shape memory alloy activated cap; an expanding shape memory alloy plug; and an expanding torque plug. Initial helium leak testing of the shape memory alloy cap and finned shape memory alloy plug seals showed hermetic- seal capability compared against an industry standard of seal integrity after Martian diurnal cycles. Developmental testing is currently being done on the expanding torque plug, and expanding shape memory alloy plug seal designs. The finned shape memory alloy (SMA) plug currently shows hermetic sealing capability based on preliminary tests.

  16. Sampling Theorem in Terms of the Bandwidth and Sampling Interval

    Science.gov (United States)

    Dean, Bruce H.

    2011-01-01

    An approach has been developed for interpolating non-uniformly sampled data, with applications in signal and image reconstruction. This innovation generalizes the Whittaker-Shannon sampling theorem by emphasizing two assumptions explicitly (definition of a band-limited function and construction by periodic extension). The Whittaker- Shannon sampling theorem is thus expressed in terms of two fundamental length scales that are derived from these assumptions. The result is more general than what is usually reported, and contains the Whittaker- Shannon form as a special case corresponding to Nyquist-sampled data. The approach also shows that the preferred basis set for interpolation is found by varying the frequency component of the basis functions in an optimal way.

  17. Defining sample size and sampling strategy for dendrogeomorphic rockfall reconstructions

    Science.gov (United States)

    Morel, Pauline; Trappmann, Daniel; Corona, Christophe; Stoffel, Markus

    2015-05-01

    Optimized sampling strategies have been recently proposed for dendrogeomorphic reconstructions of mass movements with a large spatial footprint, such as landslides, snow avalanches, and debris flows. Such guidelines have, by contrast, been largely missing for rockfalls and cannot be transposed owing to the sporadic nature of this process and the occurrence of individual rocks and boulders. Based on a data set of 314 European larch (Larix decidua Mill.) trees (i.e., 64 trees/ha), growing on an active rockfall slope, this study bridges this gap and proposes an optimized sampling strategy for the spatial and temporal reconstruction of rockfall activity. Using random extractions of trees, iterative mapping, and a stratified sampling strategy based on an arbitrary selection of trees, we investigate subsets of the full tree-ring data set to define optimal sample size and sampling design for the development of frequency maps of rockfall activity. Spatially, our results demonstrate that the sampling of only 6 representative trees per ha can be sufficient to yield a reasonable mapping of the spatial distribution of rockfall frequencies on a slope, especially if the oldest and most heavily affected individuals are included in the analysis. At the same time, however, sampling such a low number of trees risks causing significant errors especially if nonrepresentative trees are chosen for analysis. An increased number of samples therefore improves the quality of the frequency maps in this case. Temporally, we demonstrate that at least 40 trees/ha are needed to obtain reliable rockfall chronologies. These results will facilitate the design of future studies, decrease the cost-benefit ratio of dendrogeomorphic studies and thus will permit production of reliable reconstructions with reasonable temporal efforts.

  18. Curation of Samples from Mars

    Science.gov (United States)

    Lindstrom, D.; Allen, C.

    One of the strong scientific reasons for returning samples from Mars is to search for evidence of current or past life in the samples. Because of the remote possibility that the samples may contain life forms that are hazardous to the terrestrial biosphere, the National Research Council has recommended that all samples returned from Mars be kept under strict biological containment until tests show that they can safely be released to other laboratories. It is possible that Mars samples may contain only scarce or subtle traces of life or prebiotic chemistry that could readily be overwhelmed by terrestrial contamination. Thus, the facilities used to contain, process, and analyze samples from Mars must have a combination of high-level biocontainment and organic / inorganic chemical cleanliness that is unprecedented. We have been conducting feasibility studies and developing designs for a facility that would be at least as capable as current maximum containment BSL-4 (BioSafety Level 4) laboratories, while simultaneously maintaining cleanliness levels exceeding those of the cleanest electronics manufacturing labs. Unique requirements for the processing of Mars samples have inspired a program to develop handling techniques that are much more precise and reliable than the approach (currently used for lunar samples) of employing gloved human hands in nitrogen-filled gloveboxes. Individual samples from Mars are expected to be much smaller than lunar samples, the total mass of samples returned by each mission being 0.5- 1 kg, compared with many tens of kg of lunar samples returned by each of the six Apollo missions. Smaller samp les require much more of the processing to be done under microscopic observation. In addition, the requirements for cleanliness and high-level containment would be difficult to satisfy while using traditional gloveboxes. JSC has constructed a laboratory to test concepts and technologies important to future sample curation. The Advanced Curation

  19. Sampling of illicit drugs for quantitative analysis--part III: sampling plans and sample preparations.

    Science.gov (United States)

    Csesztregi, T; Bovens, M; Dujourdy, L; Franc, A; Nagy, J

    2014-08-01

    The findings in this paper are based on the results of our drug homogeneity studies and particle size investigations. Using that information, a general sampling plan (depicted in the form of a flow-chart) was devised that could be applied to the quantitative instrumental analysis of the most common illicit drugs: namely heroin, cocaine, amphetamine, cannabis resin, MDMA tablets and herbal cannabis in 'bud' form (type I). Other more heterogeneous forms of cannabis (type II) were found to require alternative, more traditional sampling methods. A table was constructed which shows the sampling uncertainty expected when a particular number of random increments are taken and combined to form a single primary sample. It also includes a recommended increment size; which is 1 g for powdered drugs and cannabis resin, 1 tablet for MDMA and 1 bud for herbal cannabis in bud form (type I). By referring to that table, individual laboratories can ensure that the sampling uncertainty for a particular drug seizure can be minimised, such that it lies in the same region as their analytical uncertainty for that drug. The table shows that assuming a laboratory wishes to quantitatively analyse a seizure of powdered drug or cannabis resin with a 'typical' heterogeneity, a primary sample of 15×1 g increments is generally appropriate. The appropriate primary sample for MDMA tablets is 20 tablets, while for herbal cannabis (in bud form) 50 buds were found to be appropriate. Our study also showed that, for a suitably homogenised primary sample of the most common powdered drugs, an analytical sample size of between 20 and 35 mg was appropriate and for herbal cannabis the appropriate amount was 200 mg. The need to ensure that the results from duplicate or multiple incremental sampling were compared, to demonstrate whether or not a particular seized material has a 'typical' heterogeneity and that the sampling procedure applied has resulted in a 'correct sample', was highlighted and the setting

  20. Defining And Characterizing Sample Representativeness For DWPF Melter Feed Samples

    Energy Technology Data Exchange (ETDEWEB)

    Shine, E. P.; Poirier, M. R.

    2013-10-29

    Representative sampling is important throughout the Defense Waste Processing Facility (DWPF) process, and the demonstrated success of the DWPF process to achieve glass product quality over the past two decades is a direct result of the quality of information obtained from the process. The objective of this report was to present sampling methods that the Savannah River Site (SRS) used to qualify waste being dispositioned at the DWPF. The goal was to emphasize the methodology, not a list of outcomes from those studies. This methodology includes proven methods for taking representative samples, the use of controlled analytical methods, and data interpretation and reporting that considers the uncertainty of all error sources. Numerous sampling studies were conducted during the development of the DWPF process and still continue to be performed in order to evaluate options for process improvement. Study designs were based on use of statistical tools applicable to the determination of uncertainties associated with the data needs. Successful designs are apt to be repeated, so this report chose only to include prototypic case studies that typify the characteristics of frequently used designs. Case studies have been presented for studying in-tank homogeneity, evaluating the suitability of sampler systems, determining factors that affect mixing and sampling, comparing the final waste glass product chemical composition and durability to that of the glass pour stream sample and other samples from process vessels, and assessing the uniformity of the chemical composition in the waste glass product. Many of these studies efficiently addressed more than one of these areas of concern associated with demonstrating sample representativeness and provide examples of statistical tools in use for DWPF. The time when many of these designs were implemented was in an age when the sampling ideas of Pierre Gy were not as widespread as they are today. Nonetheless, the engineers and

  1. Mars Science Laboratory Sample Acquisition, Sample Processing and Handling Subsystem: A Description of the Sampling Functionality

    Science.gov (United States)

    Jandura, L.; Burke, K.; Kennedy, B.; Melko, J.; Okon, A.; Sunshine, D.

    2009-12-01

    The Sample Acquisition/Sample Processing and Handling (SA/SPaH) subsystem for the Mars Science Library (MSL) is a rover-based sampling system scheduled to launch in 2011. The SA/SPaH consists of a powdering drill and a scooping, sieving, and portioning device mounted on a turret at the end of a robotic arm. Also on the turret is a dust removal tool for clearing the surface of scientific targets, and two science instruments mounted on vibration isolators. The SA/SPaH can acquire powder from rocks at depths of 20 to 50 mm and can also pick up loose regolith with its scoop. The acquired sample is sieved and portioned and delivered to one of two instruments inside the rover for analysis. The functionality of the system will be described along with the targets the system can acquire and the sample that can be delivered. Top View of the SA/SPaH on the Rover

  2. Continuous sampling from distributed streams

    DEFF Research Database (Denmark)

    Graham, Cormode; Muthukrishnan, S.; Yi, Ke

    2012-01-01

    A fundamental problem in data management is to draw and maintain a sample of a large data set, for approximate query answering, selectivity estimation, and query planning. With large, streaming data sets, this problem becomes particularly difficult when the data is shared across multiple...... distributed sites. The main challenge is to ensure that a sample is drawn uniformly across the union of the data while minimizing the communication needed to run the protocol on the evolving data. At the same time, it is also necessary to make the protocol lightweight, by keeping the space and time costs low...... for each participant. In this article, we present communication-efficient protocols for continuously maintaining a sample (both with and without replacement) from k distributed streams. These apply to the case when we want a sample from the full streams, and to the sliding window cases of only the W most...

  3. Sample size determination and power

    CERN Document Server

    Ryan, Thomas P, Jr

    2013-01-01

    THOMAS P. RYAN, PhD, teaches online advanced statistics courses for Northwestern University and The Institute for Statistics Education in sample size determination, design of experiments, engineering statistics, and regression analysis.

  4. Microfluidic Sample Preparation for Immunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Visuri, S; Benett, W; Bettencourt, K; Chang, J; Fisher, K; Hamilton, J; Krulevitch, P; Park, C; Stockton, C; Tarte, L; Wang, A; Wilson, T

    2001-08-09

    Researchers at Lawrence Livermore National Laboratory are developing means to collect and identify fluid-based biological pathogens in the forms of proteins, viruses, and bacteria. to support detection instruments, they are developing a flexible fluidic sample preparation unit. The overall goal of this Microfluidic Module is to input a fluid sample, containing background particulates and potentially target compounds, and deliver a processed sample for detection. They are developing techniques for sample purification, mixing, and filtration that would be useful to many applications including immunologic and nucleic acid assays. Many of these fluidic functions are accomplished with acoustic radiation pressure or dielectrophoresis. They are integrating these technologies into packaged systems with pumps and valves to control fluid flow through the fluidic circuit.

  5. Subsurface Noble Gas Sampling Manual

    Energy Technology Data Exchange (ETDEWEB)

    Carrigan, C. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sun, Y. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-18

    The intent of this document is to provide information about best available approaches for performing subsurface soil gas sampling during an On Site Inspection or OSI. This information is based on field sampling experiments, computer simulations and data from the NA-22 Noble Gas Signature Experiment Test Bed at the Nevada Nuclear Security Site (NNSS). The approaches should optimize the gas concentration from the subsurface cavity or chimney regime while simultaneously minimizing the potential for atmospheric radioxenon and near-surface Argon-37 contamination. Where possible, we quantitatively assess differences in sampling practices for the same sets of environmental conditions. We recognize that all sampling scenarios cannot be addressed. However, if this document helps to inform the intuition of the reader about addressing the challenges resulting from the inevitable deviations from the scenario assumed here, it will have achieved its goal.

  6. SWOT ANALYSIS ON SAMPLING METHOD

    National Research Council Canada - National Science Library

    CHIS ANCA OANA; BELENESI MARIOARA;

    2014-01-01

    .... Our article aims to study audit sampling in audit of financial statements. As an audit technique largely used, in both its statistical and nonstatistical form, the method is very important for auditors...

  7. Biological Sample Monitoring Database (BSMDBS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Biological Sample Monitoring Database System (BSMDBS) was developed for the Northeast Fisheries Regional Office and Science Center (NER/NEFSC) to record and...

  8. Tests on standard concrete samples

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Compression and tensile tests on standard concrete samples. The use of centrifugal force in tensile testing has been developed by the SB Division and the instruments were built in the Central workshops.

  9. More practical critical height sampling.

    Science.gov (United States)

    Thomas B. Lynch; Jeffrey H. Gove

    2015-01-01

    Critical Height Sampling (CHS) (Kitamura 1964) can be used to predict cubic volumes per acre without using volume tables or equations. The critical height is defined as the height at which the tree stem appears to be in borderline condition using the point-sampling angle gauge (e.g. prism). An estimate of cubic volume per acre can be obtained from multiplication of the...

  10. Biological Environmental Sampling Technologies Assessment

    Science.gov (United States)

    2015-12-01

    array‐based measurements that are made on carbon ink surfaces. The instrument can process a wide variety of sample types and is targeted at...from all types of surfaces and absorb unknown liquids. The Aklus Shield system can also be used to sample debris, soil, or vegetation . For this...system is already part of the selected JBTDS system. Therefore, if the InnovaPrep system was selected, it would reduce the logistical footprint of

  11. Sampling Operations on Big Data

    Science.gov (United States)

    2015-11-29

    big data in Section II, followed by a description of the analytic environment D4M in Section III. We then describe the types of sampling methods and...signal reconstruction steps are used to do these operations. Big Data analytics , often characterized by analytics applied to datasets that strain available...Sampling Operations on Big Data Vijay Gadepally, Taylor Herr, Luke Johnson, Lauren Milechin, Maja Milosavljevic, Benjamin A. Miller Lincoln

  12. Biofouling development on plasma treated samples versus layers coated samples

    Science.gov (United States)

    Hnatiuc, B.; Exnar, P.; Sabau, A.; Spatenka, P.; Dumitrache, C. L.; Hnatiuc, M.; Ghita, S.

    2016-12-01

    Biofouling is the most important cause of naval corrosion. In order to reduce the Biofouling development on naval materials as steel or resin, different new methods have been tested. These methods could help to follow the new IMO environment reglementations and they could replace few classic operations before the painting of the small ships. The replacement of these operations means a reduction in maintenance costs. Their action must influence especially the first two steps of the Biofouling development, called Microfouling, that demand about 24 hours. This work presents the comparative results of the Biofouling development on two different classic naval materials, steel and resin, for three treated samples, immersed in sea water. Non-thermal plasma, produced by GlidArc technology, is applied to the first sample, called GD. The plasma treatment was set to 10 minutes. The last two samples, called AE9 and AE10 are covered by hydrophobic layers, prepared from a special organic-inorganic sol synthesized by sol-gel method. Theoretically, because of the hydrophobic properties, the Biofouling formation must be delayed for AE9 and AE10. The Biofouling development on each treated sample was compared with a witness non-treated sample. The microbiological analyses have been done for 24 hours by epifluorescence microscopy, available for one single layer.

  13. Are most samples of animals systematically biased? Consistent individual trait differences bias samples despite random sampling.

    Science.gov (United States)

    Biro, Peter A

    2013-02-01

    Sampling animals from the wild for study is something nearly every biologist has done, but despite our best efforts to obtain random samples of animals, 'hidden' trait biases may still exist. For example, consistent behavioral traits can affect trappability/catchability, independent of obvious factors such as size and gender, and these traits are often correlated with other repeatable physiological and/or life history traits. If so, systematic sampling bias may exist for any of these traits. The extent to which this is a problem, of course, depends on the magnitude of bias, which is presently unknown because the underlying trait distributions in populations are usually unknown, or unknowable. Indeed, our present knowledge about sampling bias comes from samples (not complete population censuses), which can possess bias to begin with. I had the unique opportunity to create naturalized populations of fish by seeding each of four small fishless lakes with equal densities of slow-, intermediate-, and fast-growing fish. Using sampling methods that are not size-selective, I observed that fast-growing fish were up to two-times more likely to be sampled than slower-growing fish. This indicates substantial and systematic bias with respect to an important life history trait (growth rate). If correlations between behavioral, physiological and life-history traits are as widespread as the literature suggests, then many animal samples may be systematically biased with respect to these traits (e.g., when collecting animals for laboratory use), and affect our inferences about population structure and abundance. I conclude with a discussion on ways to minimize sampling bias for particular physiological/behavioral/life-history types within animal populations.

  14. Method and apparatus utilizing ionizing and microwave radiation for saturation determination of water, oil and a gas in a core sample

    Science.gov (United States)

    Maerefat, Nicida L.; Parmeswar, Ravi; Brinkmeyer, Alan D.; Honarpour, Mehdi

    1994-01-01

    A system for determining the relative permeabilities of gas, water and oil in a core sample has a microwave emitter/detector subsystem and an X-ray emitter/detector subsystem. A core holder positions the core sample between microwave absorbers which prevent diffracted microwaves from reaching a microwave detector where they would reduce the signal-to-noise ratio of the microwave measurements. The microwave emitter/detector subsystem and the X-ray emitter/detector subsystem each have linear calibration characteristics, allowing one subsystem to be calibrated with respect to the other subsystem. The dynamic range of microwave measurements is extended through the use of adjustable attenuators. This also facilitates the use of core samples with wide diameters. The stratification characteristics of the fluids may be observed with a windowed cell separator at the outlet of the core sample. The condensation of heavy hydrocarbon gas and the dynamic characteristics of the fluids are observed with a sight glass at the outlet of the core sample.

  15. SWOT ANALYSIS ON SAMPLING METHOD

    Directory of Open Access Journals (Sweden)

    CHIS ANCA OANA

    2014-07-01

    Full Text Available Audit sampling involves the application of audit procedures to less than 100% of items within an account balance or class of transactions. Our article aims to study audit sampling in audit of financial statements. As an audit technique largely used, in both its statistical and nonstatistical form, the method is very important for auditors. It should be applied correctly for a fair view of financial statements, to satisfy the needs of all financial users. In order to be applied correctly the method must be understood by all its users and mainly by auditors. Otherwise the risk of not applying it correctly would cause loose of reputation and discredit, litigations and even prison. Since there is not a unitary practice and methodology for applying the technique, the risk of incorrectly applying it is pretty high. The SWOT analysis is a technique used that shows the advantages, disadvantages, threats and opportunities. We applied SWOT analysis in studying the sampling method, from the perspective of three players: the audit company, the audited entity and users of financial statements. The study shows that by applying the sampling method the audit company and the audited entity both save time, effort and money. The disadvantages of the method are difficulty in applying and understanding its insight. Being largely used as an audit method and being a factor of a correct audit opinion, the sampling method’s advantages, disadvantages, threats and opportunities must be understood by auditors.

  16. Distance sampling methods and applications

    CERN Document Server

    Buckland, S T; Marques, T A; Oedekoven, C S

    2015-01-01

    In this book, the authors cover the basic methods and advances within distance sampling that are most valuable to practitioners and in ecology more broadly. This is the fourth book dedicated to distance sampling. In the decade since the last book published, there have been a number of new developments. The intervening years have also shown which advances are of most use. This self-contained book covers topics from the previous publications, while also including recent developments in method, software and application. Distance sampling refers to a suite of methods, including line and point transect sampling, in which animal density or abundance is estimated from a sample of distances to detected individuals. The book illustrates these methods through case studies; data sets and computer code are supplied to readers through the book’s accompanying website.  Some of the case studies use the software Distance, while others use R code. The book is in three parts.  The first part addresses basic methods, the ...

  17. Sample Results from Routine Salt Batch 7 Samples

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. [Savannah River Site (SRS), Aiken, SC (United States)

    2015-05-13

    Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 7B have been analyzed for 238Pu, 90Sr, 137Cs, Inductively Coupled Plasma Emission Spectroscopy (ICPES), and Ion Chromatography Anions (IC-A). The results from the current microbatch samples are similar to those from earlier samples from this and previous macrobatches. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal, and there is a distinct positive trend in Cs removal, due to the use of the Next Generation Solvent (NGS). The Savannah River National Laboratory (SRNL) notes that historically, most measured Concentration Factor (CF) values during salt processing have been in the 12-14 range. However, recent processing gives CF values closer to 11. This observation does not indicate that the solvent performance is suffering, as the Decontamination Factor (DF) has still maintained consistently high values. Nevertheless, SRNL will continue to monitor for indications of process upsets. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior.

  18. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1997-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL)(a) for the US Department of Energy (DOE). This document contains the planned 1997 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. In addition, Section 3.0, Biota, also reflects a rotating collection schedule identifying the year a specific sample is scheduled for collection. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program, and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling methods will be the same as those described in the Environmental Monitoring Plan, US Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 1, US Department of Energy, Richland, Washington.

  19. β-NMR sample optimization

    CERN Document Server

    Zakoucka, Eva

    2013-01-01

    During my summer student programme I was working on sample optimization for a new β-NMR project at the ISOLDE facility. The β-NMR technique is well-established in solid-state physics and just recently it is being introduced for applications in biochemistry and life sciences. The β-NMR collaboration will be applying for beam time to the INTC committee in September for three nuclei: Cu, Zn and Mg. Sample optimization for Mg was already performed last year during the summer student programme. Therefore sample optimization for Cu and Zn had to be completed as well for the project proposal. My part in the project was to perform thorough literature research on techniques studying Cu and Zn complexes in native conditions, search for relevant binding candidates for Cu and Zn applicable for ß-NMR and eventually evaluate selected binding candidates using UV-VIS spectrometry.

  20. Ball assisted device for analytical surface sampling

    Science.gov (United States)

    ElNaggar, Mariam S; Van Berkel, Gary J; Covey, Thomas R

    2015-11-03

    A system for sampling a surface includes a sampling probe having a housing and a socket, and a rolling sampling sphere within the socket. The housing has a sampling fluid supply conduit and a sampling fluid exhaust conduit. The sampling fluid supply conduit supplies sampling fluid to the sampling sphere. The sampling fluid exhaust conduit has an inlet opening for receiving sampling fluid carried from the surface by the sampling sphere. A surface sampling probe and a method for sampling a surface are also disclosed.

  1. The ocean sampling day consortium

    DEFF Research Database (Denmark)

    Kopf, Anna; Bicak, Mesude; Kottmann, Renzo

    2015-01-01

    Ocean Sampling Day was initiated by the EU-funded Micro B3 (Marine Microbial Biodiversity, Bioinformatics, Biotechnology) project to obtain a snapshot of the marine microbial biodiversity and function of the world’s oceans. It is a simultaneous global mega-sequencing campaign aiming to generate...... the largest standardized microbial data set in a single day. This will be achievable only through the coordinated efforts of an Ocean Sampling Day Consortium, supportive partnerships and networks between sites. This commentary outlines the establishment, function and aims of the Consortium and describes our...... vision for a sustainable study of marine microbial communities and their embedded functional traits....

  2. Sampling for stereology in lungs

    Directory of Open Access Journals (Sweden)

    J. R. Nyengaard

    2006-12-01

    Full Text Available The present article reviews the relevant stereological estimators for obtaining reliable quantitative structural data from the lungs. Stereological sampling achieves reliable, quantitative information either about the whole lung or complete lobes, whilst minimising the workload. Studies have used systematic random sampling, which has fixed and constant sampling probabilities on all blocks, sections and fields of view. For an estimation of total lung or lobe volume, the Cavalieri principle can be used, but it is not useful in estimating individual cell volume due to various effects from over- or underprojection. If the number of certain structures is required, two methods can be used: the disector and the fractionator. The disector method is a three-dimensional stereological probe for sampling objects according to their number. However, it may be affected on tissue deformation and, therefore, the fractionator method is often the preferred sampling principle. In this method, a known and predetermined fraction of an object is sampled in one or more steps, with the final step estimating the number. Both methods can be performed in a physical and optical manner, therefore enabling cells and larger lung structure numbers (e.g. number of alveoli to be estimated. Some estimators also require randomisation of orientation, so that all directions have an equal chance of being chosen. Using such isotropic sections, surface area, length, and diameter can be estimated on a Cavalieri set of sections. Stereology can also illustrate the potential for transport between two compartments by analysing the barrier width. Estimating the individual volume of cells can be achieved by local stereology using a two-step procedure that first samples lung cells using the disector and then introduces individual volume estimation of the sampled cells. The coefficient of error of most unbiased stereological estimators is a combination of variance from blocks, sections, fields

  3. Sample Return Primer and Handbook

    Science.gov (United States)

    Barrow, Kirk; Cheuvront, Allan; Faris, Grant; Hirst, Edward; Mainland, Nora; McGee, Michael; Szalai, Christine; Vellinga, Joseph; Wahl, Thomas; Williams, Kenneth; hide

    2007-01-01

    This three-part Sample Return Primer and Handbook provides a road map for conducting the terminal phase of a sample return mission. The main chapters describe element-by-element analyses and trade studies, as well as required operations plans, procedures, contingencies, interfaces, and corresponding documentation. Based on the experiences of the lead Stardust engineers, the topics include systems engineering (in particular range safety compliance), mission design and navigation, spacecraft hardware and entry, descent, and landing certification, flight and recovery operations, mission assurance and system safety, test and training, and the very important interactions with external support organizations (non-NASA tracking assets, landing site support, and science curation).

  4. Succinct Sampling from Discrete Distributions

    DEFF Research Database (Denmark)

    Bringmann, Karl; Larsen, Kasper Green

    2013-01-01

    We revisit the classic problem of sampling from a discrete distribution: Given n non-negative w-bit integers x_1,...,x_n, the task is to build a data structure that allows sampling i with probability proportional to x_i. The classic solution is Walker's alias method that takes, when implemented...... requirement of the classic solution for a fundamental sampling problem, on the other hand, they provide the strongest known separation between the systematic and non-systematic case for any data structure problem. Finally, we also believe our upper bounds are practically efficient and simpler than Walker...... on a Word RAM, O(n) preprocessing time, O(1) expected query time for one sample, and n(w+2 lg n+o(1)) bits of space. Using the terminology of succinct data structures, this solution has redundancy 2n lg n+o(n) bits, i.e., it uses 2n lg n+o(n) bits in addition to the information theoretic minimum required...

  5. Mahalanobis' Contributions to Sample Surveys

    Indian Academy of Sciences (India)

    has more than 60 research publications in various journals and is a Member of the International. Statistical Institute. Rao is on the Governing Council of the National Sample. Survey Organisation and is the Managing Editor of. Sankhya, Series B as well as a coeditor. ______ LAA~AA< ______ __. RESONANCE I June 1999.

  6. Sampling Assumptions in Inductive Generalization

    Science.gov (United States)

    Navarro, Daniel J.; Dry, Matthew J.; Lee, Michael D.

    2012-01-01

    Inductive generalization, where people go beyond the data provided, is a basic cognitive capability, and it underpins theoretical accounts of learning, categorization, and decision making. To complete the inductive leap needed for generalization, people must make a key "sampling" assumption about how the available data were generated.…

  7. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.

  8. The Lyman alpha reference sample

    DEFF Research Database (Denmark)

    Hayes, M.; Östlin, G.; Schaerer, D.

    2013-01-01

    We report on new imaging observations of the Lyman alpha emission line (Lyα), performed with the Hubble Space Telescope, that comprise the backbone of the Lyman alpha Reference Sample. We present images of 14 starburst galaxies at redshifts 0.028

  9. The RECONS 10 Parsec Sample

    Science.gov (United States)

    Henry, Todd; Dieterich, Sergio; Finch, C.; Ianna, P. A.; Jao, W.-C.; Riedel, Adric; Subasavage, John; Winters, J.; RECONS Team

    2018-01-01

    The sample of stars, brown dwarfs, and exoplanets known within 10 parsecs of our Solar System as of January 1, 2017 is presented. The current census is comprised of 416 objects made up of 371 stars (including the Sun and white dwarfs) and 45 brown dwarfs. The stars are known to be orbited by 43 planets (eight in our Solar System and 35 exoplanets). There are 309 systems within 10 pc, including 275 with stellar primaries and 34 systems containing only brown dwarfs.Via a long-term astrometric effort at CTIO, the RECONS (REsearch Consortium On Nearby Stars, www.recons.org) team has added 44 stellar systems to the sample, accounting for one of every seven systems known within 10 pc. Overall, the 278 red dwarfs clearly dominate the sample, accounting for 75% of all stars known within 10 pc. The completeness of the sample is assessed, indicating that a few red, brown, and white dwarfs within 10 pc may be discovered, both as primaries and secondaries, although we estimate that 90% of the stellar systems have been identified. The evolution of the 10 pc sample over the past century is outlined to illustrate our growing knowledge of the solar neighborhood.The luminosity and mass functions for stars within 10 pc are described. In contrast to many studies, once all known close multiples are resolved into individual components, the true mass function rises to the end of the stellar main sequence, followed by a precipitous drop in the number of brown dwarfs, which are outnumbered 8.2 to 1 by stars. Of the 275 stellar primaries in the sample, 182 (66%) are single, 75 (27%) have at least one stellar companion, only 8 (3%) have a brown dwarf companion, and 19 (7%) systems are known to harbor planets. Searches for brown dwarf companions to stars in this sample have been quite rigorous, so the brown dwarf companion rate is unlikely to rise significantly. In contrast, searches for exoplanets, particularly terrestrial planets, have been limited. Thus, overall the solar neighborhood is

  10. Apparatus for Sampling Surface Contamination

    Science.gov (United States)

    Wells, Mark

    2008-01-01

    An apparatus denoted a swab device has been developed as a convenient means of acquiring samples of contaminants from surfaces and suspending the samples in liquids. (Thereafter, the liquids can be dispensed, in controlled volumes, into scientific instruments for analysis of the contaminants.) The swab device is designed so as not to introduce additional contamination and to facilitate, simplify, and systematize the dispensing of controlled volumes of liquid into analytical instruments. The swab device is a single apparatus into which are combined all the equipment and materials needed for sampling surface contamination. The swab device contains disposable components stacked together on a nondisposable dispensing head. One of the disposable components is a supply cartridge holding a sufficient volume of liquid for one complete set of samples. (The liquid could be clean water or another suitable solvent, depending on the application.) This supply of liquid is sealed by Luer valves. At the beginning of a sampling process, the user tears open a sealed bag containing the supply cartridge. A tip on the nondisposable dispensing head is engaged with a Luer valve on one end of the supply cartridge and rotated, locking the supply cartridge on the dispensing head and opening the valve. The swab tip includes a fabric swab that is wiped across the surface of interest to acquire a sample. A sealed bag containing a disposable dispensing tip is then opened, and the swab tip is pushed into the dispensing tip until seated. The dispensing head contains a piston that passes through a spring-loaded lip seal. The air volume displaced by this piston forces the liquid out of the supply cartridge, over the swab, and into the dispensing tip. The piston is manually cycled to enforce oscillation of the air volume and thereby to cause water to flow to wash contaminants from the swab and cause the resulting liquid suspension of contaminants to flow into the dispensing tip. After several cycles

  11. Authentication of forensic DNA samples.

    Science.gov (United States)

    Frumkin, Dan; Wasserstrom, Adam; Davidson, Ariane; Grafit, Arnon

    2010-02-01

    Over the past twenty years, DNA analysis has revolutionized forensic science, and has become a dominant tool in law enforcement. Today, DNA evidence is key to the conviction or exoneration of suspects of various types of crime, from theft to rape and murder. However, the disturbing possibility that DNA evidence can be faked has been overlooked. It turns out that standard molecular biology techniques such as PCR, molecular cloning, and recently developed whole genome amplification (WGA), enable anyone with basic equipment and know-how to produce practically unlimited amounts of in vitro synthesized (artificial) DNA with any desired genetic profile. This artificial DNA can then be applied to surfaces of objects or incorporated into genuine human tissues and planted in crime scenes. Here we show that the current forensic procedure fails to distinguish between such samples of blood, saliva, and touched surfaces with artificial DNA, and corresponding samples with in vivo generated (natural) DNA. Furthermore, genotyping of both artificial and natural samples with Profiler Plus((R)) yielded full profiles with no anomalies. In order to effectively deal with this problem, we developed an authentication assay, which distinguishes between natural and artificial DNA based on methylation analysis of a set of genomic loci: in natural DNA, some loci are methylated and others are unmethylated, while in artificial DNA all loci are unmethylated. The assay was tested on natural and artificial samples of blood, saliva, and touched surfaces, with complete success. Adopting an authentication assay for casework samples as part of the forensic procedure is necessary for maintaining the high credibility of DNA evidence in the judiciary system.

  12. Superfund Site Information - Site Sampling Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — This asset includes Superfund site-specific sampling information including location of samples, types of samples, and analytical chemistry characteristics of...

  13. Adaptive Sampling in Hierarchical Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Knap, J; Barton, N R; Hornung, R D; Arsenlis, A; Becker, R; Jefferson, D R

    2007-07-09

    We propose an adaptive sampling methodology for hierarchical multi-scale simulation. The method utilizes a moving kriging interpolation to significantly reduce the number of evaluations of finer-scale response functions to provide essential constitutive information to a coarser-scale simulation model. The underlying interpolation scheme is unstructured and adaptive to handle the transient nature of a simulation. To handle the dynamic construction and searching of a potentially large set of finer-scale response data, we employ a dynamic metric tree database. We study the performance of our adaptive sampling methodology for a two-level multi-scale model involving a coarse-scale finite element simulation and a finer-scale crystal plasticity based constitutive law.

  14. Network reconstruction via density sampling

    CERN Document Server

    Squartini, Tiziano; Gabrielli, Andrea; Garlaschelli, Diego

    2016-01-01

    Reconstructing weighted networks from partial information is necessary in many important circumstances, e.g. for a correct estimation of systemic risk. It has been shown that, in order to achieve an accurate reconstruction, it is crucial to reliably replicate the empirical degree sequence, which is however unknown in many realistic situations. More recently, it has been found that the knowledge of the degree sequence can be replaced by the knowledge of the strength sequence, which is typically accessible, complemented by that of the total number of links, thus considerably relaxing the observational requirements. Here we further relax these requirements and devise a procedure valid when even the the total number of links is unavailable. We assume that, apart from the heterogeneity induced by the degree sequence itself, the network is homogeneous, so that its link density can be estimated by sampling subsets of nodes with representative density. We show that the best way of sampling nodes is the random selecti...

  15. Representative process sampling - in practice

    DEFF Research Database (Denmark)

    Esbensen, Kim; Friis-Pedersen, Hans Henrik; Julius, Lars Petersen

    2007-01-01

    Didactic data sets representing a range of real-world processes are used to illustrate "how to do" representative process sampling and process characterisation. The selected process data lead to diverse variogram expressions with different systematics (no range vs. important ranges; trends and/or...... presented cases of variography either solved the initial problems or served to understand the reasons and causes behind the specific process structures revealed in the variograms. Process Analytical Technologies (PAT) are not complete without process TOS....

  16. Pseudo-Marginal Slice Sampling

    OpenAIRE

    Murray, Iain; Graham, Matthew

    2015-01-01

    Markov chain Monte Carlo (MCMC) methods asymptotically sample from complex probability distributions. The pseudo-marginal MCMC framework only requires an unbiased estimator of the unnormalized probability distribution function to construct a Markov chain. However, the resulting chains are harder to tune to a target distribution than conventional MCMC, and the types of updates available are limited. We describe a general way to clamp and update the random numbers used in a pseudo-marginal meth...

  17. Accurate sampling using Langevin dynamics

    CERN Document Server

    Bussi, Giovanni

    2008-01-01

    We show how to derive a simple integrator for the Langevin equation and illustrate how it is possible to check the accuracy of the obtained distribution on the fly, using the concept of effective energy introduced in a recent paper [J. Chem. Phys. 126, 014101 (2007)]. Our integrator leads to correct sampling also in the difficult high-friction limit. We also show how these ideas can be applied in practical simulations, using a Lennard-Jones crystal as a paradigmatic case.

  18. Model-based distance sampling

    OpenAIRE

    Buckland, Stephen Terrence; Oedekoven, Cornelia Sabrina; Borchers, David Louis

    2015-01-01

    CSO was part-funded by EPSRC/NERC Grant EP/1000917/1. Conventional distance sampling adopts a mixed approach, using model-based methods for the detection process, and design-based methods to estimate animal abundance in the study region, given estimated probabilities of detection. In recent years, there has been increasing interest in fully model-based methods. Model-based methods are less robust for estimating animal abundance than conventional methods, but offer several advantages: they ...

  19. Focused conformational sampling in proteins

    Science.gov (United States)

    Bacci, Marco; Langini, Cassiano; Vymětal, Jiří; Caflisch, Amedeo; Vitalis, Andreas

    2017-11-01

    A detailed understanding of the conformational dynamics of biological molecules is difficult to obtain by experimental techniques due to resolution limitations in both time and space. Computer simulations avoid these in theory but are often too short to sample rare events reliably. Here we show that the progress index-guided sampling (PIGS) protocol can be used to enhance the sampling of rare events in selected parts of biomolecules without perturbing the remainder of the system. The method is very easy to use as it only requires as essential input a set of several features representing the parts of interest sufficiently. In this feature space, new states are discovered by spontaneous fluctuations alone and in unsupervised fashion. Because there are no energetic biases acting on phase space variables or projections thereof, the trajectories PIGS generates can be analyzed directly in the framework of transition networks. We demonstrate the possibility and usefulness of such focused explorations of biomolecules with two loops that are part of the binding sites of bromodomains, a family of epigenetic "reader" modules. This real-life application uncovers states that are structurally and kinetically far away from the initial crystallographic structures and are also metastable. Representative conformations are intended to be used in future high-throughput virtual screening campaigns.

  20. Characterization of superconducting multilayers samples

    CERN Document Server

    Antoine, C Z; Berry, S; Bouat, S; Jacquot, J F; Villegier, J C; Lamura, G; Gurevich, A

    2009-01-01

    Best RF bulk niobium accelerating cavities have nearly reached their ultimate limits at rf equatorial magnetic field H  200 mT close to the thermodynamic critical field Hc. In 2006 Gurevich proposed to use nanoscale layers of superconducting materials with high values of Hc > HcNb for magnetic shielding of bulk niobium to increase the breakdown magnetic field inside SC RF cavities [1]. Depositing good quality layers inside a whole cavity is rather difficult but we have sputtered high quality samples by applying the technique used for the preparation of superconducting electronics circuits and characterized these samples by X-ray reflectivity, dc resistivity (PPMS) and dc magnetization (SQUID). Dc magnetization curves of a 250 nm thick Nb film have been measured, with and without a magnetron sputtered coating of a single or multiple stack of 15 nm MgO and 25 nm NbN layers. The Nb samples with/without the coating clearly exhibit different behaviors. Because SQUID measurements are influenced by edge an...

  1. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Naes, Benjamin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Olsen, Khris B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chouyyok, Wilaiwan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willingham, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Spigner, Angel C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO2F2 and UO2(NO3)2, U3O8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO2F2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.

  2. Synchronizing data from irregularly sampled sensors

    Science.gov (United States)

    Uluyol, Onder

    2017-07-11

    A system and method include receiving a set of sampled measurements for each of multiple sensors, wherein the sampled measurements are at irregular intervals or different rates, re-sampling the sampled measurements of each of the multiple sensors at a higher rate than one of the sensor's set of sampled measurements, and synchronizing the sampled measurements of each of the multiple sensors.

  3. Sampling for Machine Translation Evaluation

    OpenAIRE

    de la Fuente, Rubén

    2014-01-01

    Aquest article pretén oferir una visió general de les millors pràctiques desenvolupades a PayPal per al disseny i preparació de mostres per a diferents tasques incloses en el procés d'avaluació de la traducció automàtica. This paper intends to provide an overview of best practices developed within PayPal for designing and preparing samples for different tasks included in the process of machine translation evaluation. Este artículo pretende ofrecer una visión general de las mejores práct...

  4. Bayesian Sampling using Condition Indicators

    DEFF Research Database (Denmark)

    Faber, Michael H.; Sørensen, John Dalsgaard

    2002-01-01

    The problem of control quality of components is considered for the special case where the acceptable failure rate is low, the test costs are high and where it may be difficult or impossible to test the condition of interest directly. Based on the classical control theory and the concept...... of condition indicators introduced by Benjamin and Cornell (1970) a Bayesian approach to quality control is formulated. The formulation is then extended to the case where the quality control is based on sampling of indirect information about the condition of the components, i.e. condition indicators...

  5. Simultaneous Neutron and X-ray Tomography for Quantitative analysis of Geological Samples

    Science.gov (United States)

    LaManna, J.; Hussey, D. S.; Baltic, E.; Jacobson, D. L.

    2016-12-01

    Multiphase flow is a critical area of research for shale gas, oil recovery, underground CO2 sequestration, geothermal power, and aquifer management. It is critical to understand the porous structure of the geological formations in addition to the fluid/pore and fluid/fluid interactions. Difficulties for analyzing flow characteristics of rock cores are in obtaining 3D distribution information on the fluid flow and maintaining the cores in a state for other analysis methods. Two powerful non-destructive methods for obtaining 3D structural and compositional information are X-ray and neutron tomography. X-ray tomography produces information on density and structure while neutrons excel at acquiring the liquid phase and produces compositional information. These two methods can offer strong complementary information but are typically conducted at separate times and often at different facilities. This poses issues for obtaining dynamic and stochastic information as the sample will change between analysis modes. To address this, NIST has developed a system that allows for multimodal, simultaneous tomography using thermal neutrons and X-rays by placing a 90 keVp micro-focus X-ray tube 90° to the neutron beam. High pressure core holders that simulate underground conditions have been developed to facilitate simultaneous tomography. These cells allow for the control of confining pressure, axial load, temperature, and fluid flow through the core. This talk will give an overview the simultaneous neutron and x-ray tomography capabilities at NIST, the benefits of multimodal imaging, environmental equipment for geology studies, and several case studies that have been conducted at NIST.

  6. Critical current measurements of high-temperature superconducting short samples at a wide range of temperatures and magnetic fields.

    Science.gov (United States)

    Ma, Hongjun; Liu, Huajun; Liu, Fang; Zhang, Huahui; Ci, Lu; Shi, Yi; Lei, Lei

    2018-01-01

    High-Temperature Superconductors (HTS) are potential materials for high-field magnets, low-loss transmission cables, and Superconducting Magnetic Energy Storage (SMES) due to their high upper critical magnetic field (H c2 ) and critical temperature (T c ). The critical current (I c ) of HTS, which is one of the most important parameters for superconductor application, depends strongly on the magnetic fields and temperatures. A new I c measurement system that can carry out accurate I c measurement for HTS short samples with various temperatures (4.2-80 K), magnetic fields (0-14 T), and angles of the magnetic field (0°-90°) has been developed. The I c measurement system mainly consists of a measurement holder, temperature-control system, background magnet, test cryostat, data acquisition system, and DC power supply. The accuracy of temperature control is better than ±0.1 K over the 20-80 K range and ±0.05 K when measured below 20 K. The maximum current is over 1000 A with a measurement uncertainty of 1%. The system had been successfully used for YBa 2 Cu 3 O 7-x (YBCO) tapes I c determination with different temperatures and magnetic fields.

  7. Biobanking and international interoperability: samples.

    Science.gov (United States)

    Kiehntopf, Michael; Krawczak, Michael

    2011-09-01

    In terms of sample exchange, international collaborations between biobanks, or between biobanks and their research partners, have two important aspects. First, the donors' consent usually implies that the scope and purpose of any sample transfer to third parties is subject to major constraints. Since the legal, ethical and political framework of biobanking may differ substantially, even between countries of comparable jurisdictional systems, general rules for the international sharing of biomaterial are difficult, if not impossible, to define. Issues of uncertainty include the right to transfer the material, the scope of research allowed, and intellectual property rights. Since suitable means of international law enforcement may not be available in the context of biobanking, collaborators are advised to clarify any residual uncertainty by means of bilateral contracts, for example, in the form of material transfer agreements. Second, biobank partners may rightly expect that the biomaterial they receive for further analysis attains a certain level of quality. This implies that a biobank has to implement stringent quality control measures covering, in addition to the material transfer itself, the whole process of material acquisition, transport, pre-analytical handling and storage. Again, it may be advisable for biobank partners to claim contractual warranties for the type and quality of the biomaterial they wish to acquire.

  8. Cold SQUIDs and hot samples

    Energy Technology Data Exchange (ETDEWEB)

    Lee, T.S.C. [Univ. of California, Berkeley, CA (United States). Dept. of Physics]|[Lawrence Berkeley national Lab., CA (United States). Materials Sciences Div.

    1997-05-01

    Low transition temperature (low-{Tc}) and high-{Tc} Superconducting QUantum Interference Devices (SQUIDs) have been used to perform high-resolution magnetic measurements on samples whose temperatures are much higher than the operating temperatures of the devices. Part 1 of this work focuses on measurements of the rigidity of flux vortices in high-{Tc} superconductors using two low-{Tc} SQUIDs, one on either side of a thermally-insulated sample. The correlation between the signals of the SQUIDs is a direct measure of the extent of correlation between the movements of opposite ends of vortices. These measurements were conducted under the previously-unexplored experimental conditions of nominally-zero applied magnetic field, such that vortex-vortex interactions were unimportant, and with zero external current. At specific temperatures, the authors observed highly-correlated noise sources, suggesting that the vortices moved as rigid rods. At other temperatures, the noise was mostly uncorrelated, suggesting that the relevant vortices were pinned at more than one point along their length. Part 2 describes the design, construction, performance, and applications of a scanning high-{Tc} SQUID microscope optimized for imaging room-temperature objects with very high spatial resolution and magnetic source sensitivity.

  9. NASA's Aerosol Sampling Experiment Summary

    Science.gov (United States)

    Meyer, Marit E.

    2016-01-01

    In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

  10. TRU waste-sampling program

    Energy Technology Data Exchange (ETDEWEB)

    Warren, J.L.; Zerwekh, A.

    1985-08-01

    As part of a TRU waste-sampling program, Los Alamos National Laboratory retrieved and examined 44 drums of /sup 238/Pu- and /sup 239/Pu-contaminated waste. The drums ranged in age from 8 months to 9 years. The majority of drums were tested for pressure, and gas samples withdrawn from the drums were analyzed by a mass spectrometer. Real-time radiography and visual examination were used to determine both void volumes and waste content. Drum walls were measured for deterioration, and selected drum contents were reassayed for comparison with original assays and WIPP criteria. Each drum tested at atmospheric pressure. Mass spectrometry revealed no problem with /sup 239/Pu-contaminated waste, but three 8-month-old drums of /sup 238/Pu-contaminated waste contained a potentially hazardous gas mixture. Void volumes fell within the 81 to 97% range. Measurements of drum walls showed no significant corrosion or deterioration. All reassayed contents were within WIPP waste acceptance criteria. Five of the drums opened and examined (15%) could not be certified as packaged. Three contained free liquids, one had corrosive materials, and one had too much unstabilized particulate. Eleven drums had the wrong (or not the most appropriate) waste code. In many cases, disposal volumes had been inefficiently used. 2 refs., 23 figs., 7 tabs.

  11. Sampled-data controller implementation

    Science.gov (United States)

    Wang, Yu; Leduc, Ryan J.

    2012-09-01

    The setting of this article is the implementation of timed discrete-event systems (TDES) as sampled-data (SD) controllers. An SD controller is driven by a periodic clock and sees the system as a series of inputs and outputs. On each clock edge (tick event), it samples its inputs, changes states and updates its outputs. In this article, we establish a formal representation of an SD controller as a Moore synchronous finite state machine (FSM). We describe how to translate a TDES supervisor to an FSM, as well as necessary properties to be able to do so. We discuss how to construct a single centralised controller as well as a set of modular controllers, and show that they will produce equivalent output. We briefly discuss how the recently introduced SD controllability definition relates to our translation method. SD controllability is an extension of TDES controllability which captures several new properties that are useful in dealing with concurrency issues, as well as make it easier to translate a TDES supervisor into an SD controller. We next discuss the application of SD controllability to a small flexible manufacturing system (FMS) from the literature. The example demonstrates the successful application of the new SD properties. We describe the design of the system in detail to illustrate the new conditions and to provide designers with guidance on how to apply the properties. We also present some FSM translation issues encountered, as well as the FSM version of the system's supervisors.

  12. Towards Cost-efficient Sampling Methods

    CERN Document Server

    Peng, Luo; Chong, Wu

    2014-01-01

    The sampling method has been paid much attention in the field of complex network in general and statistical physics in particular. This paper presents two new sampling methods based on the perspective that a small part of vertices with high node degree can possess the most structure information of a network. The two proposed sampling methods are efficient in sampling the nodes with high degree. The first new sampling method is improved on the basis of the stratified random sampling method and selects the high degree nodes with higher probability by classifying the nodes according to their degree distribution. The second sampling method improves the existing snowball sampling method so that it enables to sample the targeted nodes selectively in every sampling step. Besides, the two proposed sampling methods not only sample the nodes but also pick the edges directly connected to these nodes. In order to demonstrate the two methods' availability and accuracy, we compare them with the existing sampling methods in...

  13. 40 CFR 141.21 - Coliform sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Coliform sampling. 141.21 Section 141... sampling. (a) Routine monitoring. (1) Public water systems must collect total coliform samples at sites... must collect at least one repeat sample from the sampling tap where the original total coliform...

  14. 40 CFR 1065.150 - Continuous sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Continuous sampling. 1065.150 Section... ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.150 Continuous sampling. You may use continuous sampling techniques for measurements that involve raw or dilute sampling. Make sure continuous sampling...

  15. 40 CFR 89.420 - Background sample.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Background sample. 89.420 Section 89... Procedures § 89.420 Background sample. (a) Background samples are produced by continuously drawing a sample... background samples may be produced and analyzed for each mode. Hence, a unique background value will be used...

  16. Methodology Series Module 5: Sampling Strategies.

    Science.gov (United States)

    Setia, Maninder Singh

    2016-01-01

    Once the research question and the research design have been finalised, it is important to select the appropriate sample for the study. The method by which the researcher selects the sample is the ' Sampling Method'. There are essentially two types of sampling methods: 1) probability sampling - based on chance events (such as random numbers, flipping a coin etc.); and 2) non-probability sampling - based on researcher's choice, population that accessible & available. Some of the non-probability sampling methods are: purposive sampling, convenience sampling, or quota sampling. Random sampling method (such as simple random sample or stratified random sample) is a form of probability sampling. It is important to understand the different sampling methods used in clinical studies and mention this method clearly in the manuscript. The researcher should not misrepresent the sampling method in the manuscript (such as using the term ' random sample' when the researcher has used convenience sample). The sampling method will depend on the research question. For instance, the researcher may want to understand an issue in greater detail for one particular population rather than worry about the ' generalizability' of these results. In such a scenario, the researcher may want to use ' purposive sampling' for the study.

  17. Methodology series module 5: Sampling strategies

    Directory of Open Access Journals (Sweden)

    Maninder Singh Setia

    2016-01-01

    Full Text Available Once the research question and the research design have been finalised, it is important to select the appropriate sample for the study. The method by which the researcher selects the sample is the 'Sampling Method'. There are essentially two types of sampling methods: 1 probability sampling – based on chance events (such as random numbers, flipping a coin etc.; and 2 non-probability sampling – based on researcher's choice, population that accessible & available. Some of the non-probability sampling methods are: purposive sampling, convenience sampling, or quota sampling. Random sampling method (such as simple random sample or stratified random sample is a form of probability sampling. It is important to understand the different sampling methods used in clinical studies and mention this method clearly in the manuscript. The researcher should not misrepresent the sampling method in the manuscript (such as using the term 'random sample' when the researcher has used convenience sample. The sampling method will depend on the research question. For instance, the researcher may want to understand an issue in greater detail for one particular population rather than worry about the 'generalizability' of these results. In such a scenario, the researcher may want to use 'purposive sampling' for the study.

  18. Sample Return Systems for Extreme Environments Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Since the Apollo era, sample return missions have been primarily limited to asteroid sampling. More comprehensive sampling could yield critical information on the...

  19. 40 CFR 1065.170 - Batch sampling for gaseous and PM constituents.

    Science.gov (United States)

    2010-07-01

    ... holder, cap the inlet and outlet. Keep them covered or sealed until they return to the stabilization or weighing environments. (ix) The filters should not be handled outside of the PM stabilization and weighing... electrostatic, thermophoresis, inertia, diffusion, or some other deposition mechanism, as approved. ER08OC08.079 ...

  20. Methodology series module 5: Sampling strategies

    OpenAIRE

    Maninder Singh Setia

    2016-01-01

    Once the research question and the research design have been finalised, it is important to select the appropriate sample for the study. The method by which the researcher selects the sample is the ? Sampling Method?. There are essentially two types of sampling methods: 1) probability sampling ? based on chance events (such as random numbers, flipping a coin etc.); and 2) non-probability sampling ? based on researcher's choice, population that accessible & available. Some of the non-probabilit...

  1. Zamak samples analyses using EDXRF

    Energy Technology Data Exchange (ETDEWEB)

    Assis, J.T. de; Lima, I.; Monin, V., E-mail: joaquim@iprj.uerj.b, E-mail: inaya@iprj.uerj.b, E-mail: monin@iprj.uerj.b [Universidade do Estado do Rio de Janeiro (UERJ), Nova Friburgo, RJ (Brazil). Inst. Politecnico. Dept. de Engenharia Mecanica e Energia; Anjos, M. dos; Lopes, R.T., E-mail: ricardo@lin.ufrj.b [Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear; Alves, H., E-mail: marcelin@uerj.b, E-mail: haimon.dlafis@gmail.co [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica. Dept. de Fisica Aplicada e Termodinamica

    2009-07-01

    Zamak is a family of alloys with a base metal of zinc and alloying elements of aluminium, magnesium and copper. Among all non-ferrous metal alloys, Zamak is one that has more applications, for their physical, mechanical properties and easy ability to electrodeposition. It has good resistance to corrosion, traction, shock and wear. Its low melting point (approximately 400 deg C) allows greater durability of the mold, allowing greater production of melted series parts. Zamak can be used in several kinds of areas, such as, to produce residential and industrial locks, construction and carpentry components, refrigerators hinges and so on. It is observed that in some cases the quality of these products is not very good. The problem should be the quality of Zamak alloy purchased by the industries. One possible technique that can be used to investigate the quality of these alloys is Energy Dispersive X-ray fluorescence. In this paper we present results of eight samples of Zamak alloy by this technique and it was possible to classify Zamak alloy and verify some irregularity on these alloys. (author)

  2. Graph Sampling for Covariance Estimation

    KAUST Repository

    Chepuri, Sundeep Prabhakar

    2017-04-25

    In this paper the focus is on subsampling as well as reconstructing the second-order statistics of signals residing on nodes of arbitrary undirected graphs. Second-order stationary graph signals may be obtained by graph filtering zero-mean white noise and they admit a well-defined power spectrum whose shape is determined by the frequency response of the graph filter. Estimating the graph power spectrum forms an important component of stationary graph signal processing and related inference tasks such as Wiener prediction or inpainting on graphs. The central result of this paper is that by sampling a significantly smaller subset of vertices and using simple least squares, we can reconstruct the second-order statistics of the graph signal from the subsampled observations, and more importantly, without any spectral priors. To this end, both a nonparametric approach as well as parametric approaches including moving average and autoregressive models for the graph power spectrum are considered. The results specialize for undirected circulant graphs in that the graph nodes leading to the best compression rates are given by the so-called minimal sparse rulers. A near-optimal greedy algorithm is developed to design the subsampling scheme for the non-parametric and the moving average models, whereas a particular subsampling scheme that allows linear estimation for the autoregressive model is proposed. Numerical experiments on synthetic as well as real datasets related to climatology and processing handwritten digits are provided to demonstrate the developed theory.

  3. Bilateral inferior petrosal sinus sampling.

    Science.gov (United States)

    Zampetti, Benedetta; Grossrubatscher, Erika; Dalino Ciaramella, Paolo; Boccardi, Edoardo; Loli, Paola

    2016-07-01

    Simultaneous bilateral inferior petrosal sinus sampling (BIPSS) plays a crucial role in the diagnostic work-up of Cushing's syndrome. It is the most accurate procedure in the differential diagnosis of hypercortisolism of pituitary or ectopic origin, as compared with clinical, biochemical and imaging analyses, with a sensitivity and specificity of 88-100% and 67-100%, respectively. In the setting of hypercortisolemia, ACTH levels obtained from venous drainage of the pituitary are expected to be higher than the levels of peripheral blood, thus suggesting pituitary ACTH excess as the cause of hypercortisolism. Direct stimulation of the pituitary corticotroph with corticotrophin-releasing hormone enhances the sensitivity of the procedure. The procedure must be undertaken in the presence of hypercortisolemia, which suppresses both the basal and stimulated secretory activity of normal corticotrophic cells: ACTH measured in the sinus is, therefore, the result of the secretory activity of the tumor tissue. The poor accuracy in lateralization of BIPSS (positive predictive value of 50-70%) makes interpetrosal ACTH gradient alone not sufficient for the localization of the tumor. An accurate exploration of the gland is recommended if a tumor is not found in the predicted area. Despite the fact that BIPSS is an invasive procedure, the occurrence of adverse events is extremely rare, particularly if it is performed by experienced operators in referral centres. © 2016 The authors.

  4. Bilateral inferior petrosal sinus sampling

    Directory of Open Access Journals (Sweden)

    Benedetta Zampetti

    2016-08-01

    Full Text Available Simultaneous bilateral inferior petrosal sinus sampling (BIPSS plays a crucial role in the diagnostic work-up of Cushing’s syndrome. It is the most accurate procedure in the differential diagnosis of hypercortisolism of pituitary or ectopic origin, as compared with clinical, biochemical and imaging analyses, with a sensitivity and specificity of 88–100% and 67–100%, respectively. In the setting of hypercortisolemia, ACTH levels obtained from venous drainage of the pituitary are expected to be higher than the levels of peripheral blood, thus suggesting pituitary ACTH excess as the cause of hypercortisolism. Direct stimulation of the pituitary corticotroph with corticotrophin-releasing hormone enhances the sensitivity of the procedure. The procedure must be undertaken in the presence of hypercortisolemia, which suppresses both the basal and stimulated secretory activity of normal corticotrophic cells: ACTH measured in the sinus is, therefore, the result of the secretory activity of the tumor tissue. The poor accuracy in lateralization of BIPSS (positive predictive value of 50–70% makes interpetrosal ACTH gradient alone not sufficient for the localization of the tumor. An accurate exploration of the gland is recommended if a tumor is not found in the predicted area. Despite the fact that BIPSS is an invasive procedure, the occurrence of adverse events is extremely rare, particularly if it is performed by experienced operators in referral centres.

  5. 21 CFR 203.38 - Sample lot or control numbers; labeling of sample units.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Sample lot or control numbers; labeling of sample... SERVICES (CONTINUED) DRUGS: GENERAL PRESCRIPTION DRUG MARKETING Samples § 203.38 Sample lot or control numbers; labeling of sample units. (a) Lot or control number required on drug sample labeling and sample...

  6. Tank 12H residuals sample analysis report

    Energy Technology Data Exchange (ETDEWEB)

    Oji, L. N. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Shine, E. P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Diprete, D. P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Coleman, C. J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hay, M. S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-06-11

    The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 12H final characterization samples to determine the residual tank inventory prior to grouting. Eleven Tank 12H floor and mound residual material samples and three cooling coil scrape samples were collected and delivered to SRNL between May and August of 2014.

  7. Credit in Acceptance Sampling on Attributes

    NARCIS (Netherlands)

    Klaassen, Chris A.J.

    2000-01-01

    Credit is introduced in acceptance sampling on attributes and a Credit Based Acceptance sampling system is developed that is very easy to apply in practice.The credit of a producer is defined as the total number of items accepted since the last rejection.In our sampling system the sample size for a

  8. 45 CFR 1356.84 - Sampling.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Sampling. 1356.84 Section 1356.84 Public Welfare....84 Sampling. (a) The State agency may collect and report the information required in section 1356.83(e) of this part on a sample of the baseline population consistent with the sampling requirements...

  9. 30 CFR 90.208 - Bimonthly sampling.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bimonthly sampling. 90.208 Section 90.208... MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.208 Bimonthly sampling. (a) Each operator shall take one valid respirable dust sample for...

  10. 30 CFR 90.207 - Compliance sampling.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compliance sampling. 90.207 Section 90.207... MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.207 Compliance sampling. (a) The operator shall take five valid respirable dust samples for...

  11. 42 CFR 402.109 - Statistical sampling.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Statistical sampling. 402.109 Section 402.109... Statistical sampling. (a) Purpose. CMS or OIG may introduce the results of a statistical sampling study to... or caused to be presented. (b) Prima facie evidence. The results of the statistical sampling study...

  12. 40 CFR 61.34 - Air sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air sampling. 61.34 Section 61.34... sampling. (a) Stationary sources subject to § 61.32(b) shall locate air sampling sites in accordance with a... concentrations calculated within 30 days after filters are collected. Records of concentrations at all sampling...

  13. 7 CFR 51.17 - Official sampling.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Official sampling. 51.17 Section 51.17 Agriculture... Inspection Service § 51.17 Official sampling. Samples may be officially drawn by any duly authorized... time and place of the sampling and the brands or other identifying marks of the containers from which...

  14. 40 CFR 90.422 - Background sample.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Background sample. 90.422 Section 90... Procedures § 90.422 Background sample. (a) Background samples are produced by drawing a sample of the dilution air during the exhaust collection phase of each test cycle mode. (1) An individual background...

  15. Improved variance estimation along sample eigenvectors

    NARCIS (Netherlands)

    Hendrikse, A.J.; Veldhuis, Raymond N.J.; Spreeuwers, Lieuwe Jan

    Second order statistics estimates in the form of sample eigenvalues and sample eigenvectors give a sub optimal description of the population density. So far only attempts have been made to reduce the bias in the sample eigenvalues. However, because the sample eigenvectors differ from the population

  16. Sampling wild species to conserve genetic diversity

    Science.gov (United States)

    Sampling seed from natural populations of crop wild relatives requires choice of the locations to sample from and the amount of seed to sample. While this may seem like a simple choice, in fact careful planning of a collector’s sampling strategy is needed to ensure that a crop wild collection will ...

  17. Nanopipettes: probes for local sample analysis.

    Science.gov (United States)

    Saha-Shah, Anumita; Weber, Anna E; Karty, Jonathan A; Ray, Steven J; Hieftje, Gary M; Baker, Lane A

    2015-06-01

    Nanopipettes (pipettes with diameters nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples.

  18. Separating Interviewer and Sampling-Point Effects

    OpenAIRE

    Rainer Schnell; Frauke Kreuter

    2003-01-01

    "Data used in nationwide face-to-face surveys are almost always collected in multistage cluster samples. The relative homogeneity of the clusters selected in this way can lead to design effects at the sampling stage. Interviewers can further homogenize answers within the small geographic clusters that form the sampling points. The study presented here was designed to distinguish between interviewer effects and sampling-point effects using interpenetrated samples for conducting ...

  19. Concrete samples for organic samples, data package and 222-S validation summary report. Addendum 1A

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, R.E.

    1994-11-01

    This document is in two parts: the first is the data package entitled ``Concrete Samples for Organic Samples`` and the second is entitled ``Concrete Samples for Organic Samples -- Addendum 1A`` which is the 222-S validation summary report.

  20. Using Inverse Probability Bootstrap Sampling to Eliminate Sample Induced Bias in Model Based Analysis of Unequal Probability Samples.

    Science.gov (United States)

    Nahorniak, Matthew; Larsen, David P; Volk, Carol; Jordan, Chris E

    2015-01-01

    In ecology, as in other research fields, efficient sampling for population estimation often drives sample designs toward unequal probability sampling, such as in stratified sampling. Design based statistical analysis tools are appropriate for seamless integration of sample design into the statistical analysis. However, it is also common and necessary, after a sampling design has been implemented, to use datasets to address questions that, in many cases, were not considered during the sampling design phase. Questions may arise requiring the use of model based statistical tools such as multiple regression, quantile regression, or regression tree analysis. However, such model based tools may require, for ensuring unbiased estimation, data from simple random samples, which can be problematic when analyzing data from unequal probability designs. Despite numerous method specific tools available to properly account for sampling design, too often in the analysis of ecological data, sample design is ignored and consequences are not properly considered. We demonstrate here that violation of this assumption can lead to biased parameter estimates in ecological research. In addition, to the set of tools available for researchers to properly account for sampling design in model based analysis, we introduce inverse probability bootstrapping (IPB). Inverse probability bootstrapping is an easily implemented method for obtaining equal probability re-samples from a probability sample, from which unbiased model based estimates can be made. We demonstrate the potential for bias in model-based analyses that ignore sample inclusion probabilities, and the effectiveness of IPB sampling in eliminating this bias, using both simulated and actual ecological data. For illustration, we considered three model based analysis tools--linear regression, quantile regression, and boosted regression tree analysis. In all models, using both simulated and actual ecological data, we found inferences to be

  1. Sampling a guide for internal auditors

    CERN Document Server

    Apostolou, Barbara

    2004-01-01

    While it is possible to examine 100 percent of an audit customer's data, the time and cost associated with such a study are often prohibitive. To obtain sufficient, reliable, and relevant information with a limited data set, sampling is an efficient and effective tool. It can help you evaluate the customer's assertions, as well as reach audit conclusions and provide reasonable assurance to your organization. This handbook will help you understand sampling. It also serves as a guide for auditors and students preparing for certification. Topics include: An overview of sampling. Statistical and nonstatistical sampling issues. Sampling selection methods and risks. The pros and cons of popular sampling plans.

  2. Time-weighted average sampling of airborne propylene glycol ethers by a solid-phase microextraction device.

    Science.gov (United States)

    Shih, H C; Tsai, S W; Kuo, C H

    2012-01-01

    A solid-phase microextraction (SPME) device was used as a diffusive sampler for airborne propylene glycol ethers (PGEs), including propylene glycol monomethyl ether (PGME), propylene glycol monomethyl ether acetate (PGMEA), and dipropylene glycol monomethyl ether (DPGME). Carboxen-polydimethylsiloxane (CAR/PDMS) SPME fiber was selected for this study. A polytetrafluoroethylene (PTFE) tubing was used as the holder, and the SPME fiber assembly was inserted into the tubing as a diffusive sampler. The diffusion path length and area of the sampler were 0.3 cm and 0.00086 cm(2), respectively. The theoretical sampling constants at 30°C and 1 atm for PGME, PGMEA, and DPGME were 1.50 × 10(-2), 1.23 × 10(-2) and 1.14 × 10(-2) cm(3) min(-1), respectively. For evaluations, known concentrations of PGEs around the threshold limit values/time-weighted average with specific relative humidities (10% and 80%) were generated both by the air bag method and the dynamic generation system, while 15, 30, 60, 120, and 240 min were selected as the time periods for vapor exposures. Comparisons of the SPME diffusive sampling method to Occupational Safety and Health Administration (OSHA) organic Method 99 were performed side-by-side in an exposure chamber at 30°C for PGME. A gas chromatography/flame ionization detector (GC/FID) was used for sample analysis. The experimental sampling constants of the sampler at 30°C were (6.93 ± 0.12) × 10(-1), (4.72 ± 0.03) × 10(-1), and (3.29 ± 0.20) × 10(-1) cm(3) min(-1) for PGME, PGMEA, and DPGME, respectively. The adsorption of chemicals on the stainless steel needle of the SPME fiber was suspected to be one of the reasons why significant differences between theoretical and experimental sampling rates were observed. Correlations between the results for PGME from both SPME device and OSHA organic Method 99 were linear (r = 0.9984) and consistent (slope = 0.97 ± 0.03). Face velocity (0-0.18 m/s) also proved to have no effects on the sampler

  3. Dynamic Method for Identifying Collected Sample Mass

    Science.gov (United States)

    Carson, John

    2008-01-01

    G-Sample is designed for sample collection missions to identify the presence and quantity of sample material gathered by spacecraft equipped with end effectors. The software method uses a maximum-likelihood estimator to identify the collected sample's mass based on onboard force-sensor measurements, thruster firings, and a dynamics model of the spacecraft. This makes sample mass identification a computation rather than a process requiring additional hardware. Simulation examples of G-Sample are provided for spacecraft model configurations with a sample collection device mounted on the end of an extended boom. In the absence of thrust knowledge errors, the results indicate that G-Sample can identify the amount of collected sample mass to within 10 grams (with 95-percent confidence) by using a force sensor with a noise and quantization floor of 50 micrometers. These results hold even in the presence of realistic parametric uncertainty in actual spacecraft inertia, center-of-mass offset, and first flexibility modes. Thrust profile knowledge is shown to be a dominant sensitivity for G-Sample, entering in a nearly one-to-one relationship with the final mass estimation error. This means thrust profiles should be well characterized with onboard accelerometers prior to sample collection. An overall sample-mass estimation error budget has been developed to approximate the effect of model uncertainty, sensor noise, data rate, and thrust profile error on the expected estimate of collected sample mass.

  4. Small Sample Whole-Genome Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Hara, C A; Nguyen, C P; Wheeler, E K; Sorensen, K J; Arroyo, E S; Vrankovich, G P; Christian, A T

    2005-09-20

    Many challenges arise when trying to amplify and analyze human samples collected in the field due to limitations in sample quantity, and contamination of the starting material. Tests such as DNA fingerprinting and mitochondrial typing require a certain sample size and are carried out in large volume reactions; in cases where insufficient sample is present whole genome amplification (WGA) can be used. WGA allows very small quantities of DNA to be amplified in a way that enables subsequent DNA-based tests to be performed. A limiting step to WGA is sample preparation. To minimize the necessary sample size, we have developed two modifications of WGA: the first allows for an increase in amplified product from small, nanoscale, purified samples with the use of carrier DNA while the second is a single-step method for cleaning and amplifying samples all in one column. Conventional DNA cleanup involves binding the DNA to silica, washing away impurities, and then releasing the DNA for subsequent testing. We have eliminated losses associated with incomplete sample release, thereby decreasing the required amount of starting template for DNA testing. Both techniques address the limitations of sample size by providing ample copies of genomic samples. Carrier DNA, included in our WGA reactions, can be used when amplifying samples with the standard purification method, or can be used in conjunction with our single-step DNA purification technique to potentially further decrease the amount of starting sample necessary for future forensic DNA-based assays.

  5. Aerobot Sampling and Handling System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Honeybee Robotics proposes to: ?Derive and document the functional and technical requirements for Aerobot surface sampling and sample handling across a range of...

  6. 1990 sampling of treated aspen stands

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — In mid-August, 1990, sampling of aspen stand exclosures were conducted at the National Elk Refuge. This sampling is part of a study to monitor aspen regeneration on...

  7. Revised Total Coliform Rule Lab Sampling Form

    Science.gov (United States)

    This form should be completed when a water system collects any required Revised Total Coliform Rule (RTCR) samples. It should also be used when collecting “Special” non-compliance samples for the RTCR.

  8. Extreme Environment Sampling System Deployment Mechanism Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Future Venus or Comet mission architectures may feature robotic sampling systems comprised of a Sampling Tool and Deployment Mechanism. Since 2005, Honeybee has been...

  9. AFSC/ABL: 2009 Chinook Excluder Samples

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project genetically analyzed 1,620 chinook salmon samples from the 2009 spring salmon excluder device test. These samples were collected over a short period of...

  10. ISCO Grab Sample Ion Chromatography Analytical Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — ISCO grab samples were collected from river, wastewater treatment plant discharge, and public drinking water intakes. Samples were analyzed for major ions (ppb)...

  11. Commutability of food microbiology proficiency testing samples.

    Science.gov (United States)

    Abdelmassih, M; Polet, M; Goffaux, M-J; Planchon, V; Dierick, K; Mahillon, J

    2014-03-01

    Food microbiology proficiency testing (PT) is a useful tool to assess the analytical performances among laboratories. PT items should be close to routine samples to accurately evaluate the acceptability of the methods. However, most PT providers distribute exclusively artificial samples such as reference materials or irradiated foods. This raises the issue of the suitability of these samples because the equivalence-or 'commutability'-between results obtained on artificial vs. authentic food samples has not been demonstrated. In the clinical field, the use of noncommutable PT samples has led to erroneous evaluation of the performances when different analytical methods were used. This study aimed to provide a first assessment of the commutability of samples distributed in food microbiology PT. REQUASUD and IPH organized 13 food microbiology PTs including 10-28 participants. Three types of PT items were used: genuine food samples, sterile food samples and reference materials. The commutability of the artificial samples (reference material or sterile samples) was assessed by plotting the distribution of the results on natural and artificial PT samples. This comparison highlighted matrix-correlated issues when nonfood matrices, such as reference materials, were used. Artificially inoculated food samples, on the other hand, raised only isolated commutability issues. In the organization of a PT-scheme, authentic or artificially inoculated food samples are necessary to accurately evaluate the analytical performances. Reference materials, used as PT items because of their convenience, may present commutability issues leading to inaccurate penalizing conclusions for methods that would have provided accurate results on food samples. For the first time, the commutability of food microbiology PT samples was investigated. The nature of the samples provided by the organizer turned out to be an important factor because matrix effects can impact on the analytical results. © 2013

  12. Optimal Design in Geostatistics under Preferential Sampling

    OpenAIRE

    Ferreira, Gustavo da Silva; Gamerman, Dani

    2015-01-01

    This paper analyses the effect of preferential sampling in Geostatistics when the choice of new sampling locations is the main interest of the researcher. A Bayesian criterion based on maximizing utility functions is used. Simulated studies are presented and highlight the strong influence of preferential sampling in the decisions. The computational complexity is faced by treating the new local sampling locations as a model parameter and the optimal choice is then made by analysing its posteri...

  13. Representative process sampling for reliable data analysis

    DEFF Research Database (Denmark)

    Julius, Lars Petersen; Esbensen, Kim

    2005-01-01

    Process sampling of moving streams of particulate matter, fluids and slurries (over time or space) or stationary one-dimensional (1-D) lots is often carried out according to existing tradition or protocol not taking the theory of sampling (TOS) into account. In many situations, sampling errors...

  14. 7 CFR 275.11 - Sampling.

    Science.gov (United States)

    2010-01-01

    ... FOOD STAMP AND FOOD DISTRIBUTION PROGRAM PERFORMANCE REPORTING SYSTEM Quality Control (QC) Reviews... two samples for the food stamp quality control review process, an active case sample and a negative... quality control review has an equal or known chance of being selected in the sample. Since the food stamp...

  15. Spur reduction technique for sampling PLLs

    NARCIS (Netherlands)

    Gao, X.; Bahai, A.; Klumperink, Eric A.M.; Nauta, Bram; Bohsali, M.; Djabbari, A.; Socci, G.

    2010-01-01

    Control circuitry and method of controlling a sampling phase locked loop (PLL). By controlling the duty cycle of a sampling control signal, in accordance with the PLL reference and output signals, spurious output signals from the sampling PLL being controlled can be reduced.

  16. Low power and low spur sampling PLL

    NARCIS (Netherlands)

    Gao, X.; Klumperink, Eric A.M.; Bahai, A.; Bohsali, M.; Nauta, Bram; Djabbari, A.; Socci, G.

    2010-01-01

    Abstract Control circuitry and method of controlling a sampling phase locked loop (PLL). By controlling the duty cycle of one or more sampling control signals, power consumption by the reference signal buffer and spurious output signals from the sampling PLL being controlled can be reduced.

  17. 45 CFR 160.536 - Statistical sampling.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Statistical sampling. 160.536 Section 160.536... REQUIREMENTS GENERAL ADMINISTRATIVE REQUIREMENTS Procedures for Hearings § 160.536 Statistical sampling. (a) In... statistical sampling study as evidence of the number of violations under § 160.406 of this part, or the...

  18. 40 CFR 761.348 - Contemporaneous sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Contemporaneous sampling. 761.348... PROHIBITIONS Sampling Non-Liquid, Non-Metal PCB Bulk Product Waste for Purposes of Characterization for PCB Disposal in Accordance With § 761.62, and Sampling PCB Remediation Waste Destined for Off-Site Disposal...

  19. 10 CFR 430.63 - Sampling.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Sampling. 430.63 Section 430.63 Energy DEPARTMENT OF... Enforcement § 430.63 Sampling. (a) For purposes of a certification of compliance, the determination that a... the case of faucets, showerheads, water closets, and urinals) shall be based upon the sampling...

  20. 40 CFR 61.44 - Stack sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Stack sampling. 61.44 Section 61.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Firing § 61.44 Stack sampling. (a) Sources subject to § 61.42(b) shall be continuously sampled, during...

  1. Spur reduction technique for sampling PLLs

    NARCIS (Netherlands)

    Gao, X.; Bahai, A.; Klumperink, Eric A.M.; Nauta, Bram; Bohsali, M.; Djabbari, A.; Socci, G.

    2012-01-01

    Control circuitry and method of controlling a sampling phase locked loop (PLL). By controlling the duty cycle of a sampling control signal, in accordance with the PLL reference and output signals, spurious output signals from the sampling PLL being controlled can be reduced.

  2. Spur reduction technique for sampling PLLs

    NARCIS (Netherlands)

    Gao, X.; Bahai, Ahmad; Bohsali, Mounhir; Djabbari, Ali; Klumperink, Eric A.M.; Nauta, Bram; Socci, Gerard

    2013-01-01

    Control circuitry and method of controlling a sampling phase locked loop (PLL). By controlling the duty cycle of a sampling control signal, in accordance with the PLL reference and output signals, spurious output signals from the sampling PLL being controlled can be reduced.

  3. 19 CFR 151.10 - Sampling.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Sampling. 151.10 Section 151.10 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE General § 151.10 Sampling. When necessary, the port director...

  4. 7 CFR 75.18 - Sampling.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Sampling. 75.18 Section 75.18 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections... CERTIFICATION OF QUALITY OF AGRICULTURAL AND VEGETABLE SEEDS Inspection § 75.18 Sampling. Sampling, when...

  5. 42 CFR 1003.133 - Statistical sampling.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Statistical sampling. 1003.133 Section 1003.133... AUTHORITIES CIVIL MONEY PENALTIES, ASSESSMENTS AND EXCLUSIONS § 1003.133 Statistical sampling. (a) In meeting... statistical sampling study as evidence of the number and amount of claims and/or requests for payment as...

  6. Sample normalization methods in quantitative metabolomics.

    Science.gov (United States)

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Mixture model analysis of complex samples

    NARCIS (Netherlands)

    Wedel, M; ter Hofstede, F; Steenkamp, JBEM

    1998-01-01

    We investigate the effects of a complex sampling design on the estimation of mixture models. An approximate or pseudo likelihood approach is proposed to obtain consistent estimates of class-specific parameters when the sample arises from such a complex design. The effects of ignoring the sample

  8. Lunar and Meteorite Sample Disk for Educators

    Science.gov (United States)

    Foxworth, Suzanne; Luckey, M.; McInturff, B.; Allen, J.; Kascak, A.

    2015-01-01

    NASA Johnson Space Center (JSC) has the unique responsibility to curate NASA's extraterrestrial samples from past and future missions. Curation includes documentation, preservation, preparation and distribution of samples for research, education and public outreach. Between 1969 and 1972 six Apollo missions brought back 382 kilograms of lunar rocks, core and regolith samples, from the lunar surface. JSC also curates meteorites collected from a US cooperative effort among NASA, the National Science Foundation (NSF) and the Smithsonian Institution that funds expeditions to Antarctica. The meteorites that are collected include rocks from Moon, Mars, and many asteroids including Vesta. The sample disks for educational use include these different samples. Active relevant learning has always been important to teachers and the Lunar and Meteorite Sample Disk Program provides this active style of learning for students and the general public. The Lunar and Meteorite Sample Disks permit students to conduct investigations comparable to actual scientists. The Lunar Sample Disk contains 6 samples; Basalt, Breccia, Highland Regolith, Anorthosite, Mare Regolith and Orange Soil. The Meteorite Sample Disk contains 6 samples; Chondrite L3, Chondrite H5, Carbonaceous Chondrite, Basaltic Achondrite, Iron and Stony-Iron. Teachers are given different activities that adhere to their standards with the disks. During a Sample Disk Certification Workshop, teachers participate in the activities as students gain insight into the history, formation and geologic processes of the moon, asteroids and meteorites.

  9. Multivariate stratified sampling by stochastic multiobjective optimisation

    OpenAIRE

    Diaz-Garcia, Jose A.; Ramos-Quiroga, Rogelio

    2011-01-01

    This work considers the allocation problem for multivariate stratified random sampling as a problem of integer non-linear stochastic multiobjective mathematical programming. With this goal in mind the asymptotic distribution of the vector of sample variances is studied. Two alternative approaches are suggested for solving the allocation problem for multivariate stratified random sampling. An example is presented by applying the different proposed techniques.

  10. Illustration of Launching Samples Home from Mars

    Science.gov (United States)

    2005-01-01

    One crucial step in a Mars sample return mission would be to launch the collected sample away from the surface of Mars. This artist's concept depicts a Mars ascent vehicle for starting a sample of Mars rocks on their trip to Earth.

  11. Self-Digitization of Sample Volumes

    Science.gov (United States)

    Cohen, Dawn E.; Schneider, Thomas; Wang, Michelle; Chiu, Daniel T.

    2010-01-01

    This paper describes a very simple and robust microfluidic device for digitizing samples into an array of discrete volumes. The device is based on an inherent fluidic phenomenon, where an incoming aqueous sample divides itself into an array of chambers that have been primed with an immiscible phase. Self-digitization of sample volumes results from the interplay between fluidic forces, interfacial tension, channel geometry, and the final stability of the digitized samples in the chambers. Here we describe experiments and simulations that were used to characterize these parameters and the conditions under which the self-digitization process occurred. Unlike existing methods used to partition samples into array, our method is able to digitize 100% of a sample into a localized array without any loss of sample volume. The final volume of the discretized sample at each location is defined by the geometry and size of each chamber. Thus, we can form an array of samples with varying but predefined volumes. We exploited this feature to separate the crystal growth of otherwise concomitant polymorphs from a single solution. Additionally, we demonstrated the removal of the digitized samples from the chambers for downstream analysis, as well as the addition of reagents to the digitized samples. We believe this simple method will be useful in a broad range of applications where a large array of discretized samples is required, including digital PCR, single-cell analysis, and cell-based drug screening. PMID:20550137

  12. 7 CFR 28.908 - Samples.

    Science.gov (United States)

    2010-01-01

    .... Samples may be drawn in gins equipped with mechanical samplers approved by the Division and operated... that were drawn by a mechanical sampler at the gin may be transported with the bales to the warehouse... sample from a bale for review classification if the producer so desires. (b) Drawing of samples manual...

  13. Social network sampling using spanning trees

    Science.gov (United States)

    Jalali, Zeinab S.; Rezvanian, Alireza; Meybodi, Mohammad Reza

    2016-12-01

    Due to the large scales and limitations in accessing most online social networks, it is hard or infeasible to directly access them in a reasonable amount of time for studying and analysis. Hence, network sampling has emerged as a suitable technique to study and analyze real networks. The main goal of sampling online social networks is constructing a small scale sampled network which preserves the most important properties of the original network. In this paper, we propose two sampling algorithms for sampling online social networks using spanning trees. The first proposed sampling algorithm finds several spanning trees from randomly chosen starting nodes; then the edges in these spanning trees are ranked according to the number of times that each edge has appeared in the set of found spanning trees in the given network. The sampled network is then constructed as a sub-graph of the original network which contains a fraction of nodes that are incident on highly ranked edges. In order to avoid traversing the entire network, the second sampling algorithm is proposed using partial spanning trees. The second sampling algorithm is similar to the first algorithm except that it uses partial spanning trees. Several experiments are conducted to examine the performance of the proposed sampling algorithms on well-known real networks. The obtained results in comparison with other popular sampling methods demonstrate the efficiency of the proposed sampling algorithms in terms of Kolmogorov-Smirnov distance (KSD), skew divergence distance (SDD) and normalized distance (ND).

  14. Optimization of environmental sampling using interactive GIS.

    NARCIS (Netherlands)

    Groenigen, van J.W.; Stein, A.; Zuurbier, R.

    1997-01-01

    An interactive sampling procedure is proposed to optimize environmental risk assessment. Subsequent sampling stages were used as quantitative pre-information. With this pre-information probability maps were made using indicator kriging to direct subsequent sampling. In this way, optimal use of the

  15. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  16. METHODOLOGICAL ASPECTS OF STRATIFICATION OF AUDIT SAMPLING

    OpenAIRE

    Vilena A. Yakimova

    2013-01-01

    The article presents the methodological foundations for construction stratification audit sampling for attribute-based sampling. The sampling techniques of Russian and foreign practice is studied and stratified. The role of stratification in the audit is described. Approaches to construction of the stratification are revealed on the basis of professional judgment (qualitative methods), statistical groupings (quantitative methods) and combinatory ones (complex qualitative stratifications). Gro...

  17. Global Unique Identification of Geoscience Samples: The International Geo Sample Number (IGSN) and the System for Earth Sample Registration (SESAR)

    Science.gov (United States)

    Lehnert, K. A.; Goldstein, S. L.; Vinayagamoorthy, S.; Lenhardt, W. C.

    2005-12-01

    Data on samples represent a primary foundation of Geoscience research across disciplines, ranging from the study of climate change, to biogeochemical cycles, to mantle and continental dynamics and are key to our knowledge of the Earth's dynamical systems and evolution. Different data types are generated for individual samples by different research groups, published in different papers, and stored in different databases on a global scale. The utility of these data is critically dependent on their integration. Such integration can be achieved within a Geoscience Cyberinfrastructure, but requires unambiguous identification of samples. Currently, naming of samples is arbitrary and inconsistent and therefore severely limits our ability to share, link, and integrate sample-based data. Major problems include name duplication, and changing of names as a sample is passed along over many years to different investigators. SESAR, the System for Earth Sample Registration (http://www.geosamples.org), addresses this problem by building a registry that generates and administers globally unique identifiers for Geoscience samples: the International Geo Sample Number (IGSN). Implementation of the IGSN in data publication and digital data management will dramatically advance interoperability among information systems for sample-based data, opening an extensive range of new opportunities for discovery and for interdisciplinary approaches in research. The IGSN will also facilitate the ability of investigators to build on previously collected data on samples as new measurements are made or new techniques are developed. With potentially broad application to all types of Geoscience samples, SESAR is global in scope. It is a web-based system that can be easily accessed by individual users through an interactive web interface and by distributed client systems via standard web services. Samples can be registered individually or in batches and at various levels of granularity from entire cores

  18. [Variance estimation considering multistage sampling design in multistage complex sample analysis].

    Science.gov (United States)

    Li, Yichong; Zhao, Yinjun; Wang, Limin; Zhang, Mei; Zhou, Maigeng

    2016-03-01

    Multistage sampling is a frequently-used method in random sampling survey in public health. Clustering or independence between observations often exists in the sampling, often called complex sample, generated by multistage sampling. Sampling error may be underestimated and the probability of type I error may be increased if the multistage sample design was not taken into consideration in analysis. As variance (error) estimator in complex sample is often complicated, statistical software usually adopt ultimate cluster variance estimate (UCVE) to approximate the estimation, which simply assume that the sample comes from one-stage sampling. However, with increased sampling fraction of primary sampling unit, contribution from subsequent sampling stages is no more trivial, and the ultimate cluster variance estimate may, therefore, lead to invalid variance estimation. This paper summarize a method of variance estimation considering multistage sampling design. The performances are compared with UCVE and the method considering multistage sampling design by simulating random sampling under different sampling schemes using real world data. Simulation showed that as primary sampling unit (PSU) sampling fraction increased, UCVE tended to generate increasingly biased estimation, whereas accurate estimates were obtained by using the method considering multistage sampling design.

  19. Handling missing data in ranked set sampling

    CERN Document Server

    Bouza-Herrera, Carlos N

    2013-01-01

    The existence of missing observations is a very important aspect to be considered in the application of survey sampling, for example. In human populations they may be caused by a refusal of some interviewees to give the true value for the variable of interest. Traditionally, simple random sampling is used to select samples. Most statistical models are supported by the use of samples selected by means of this design. In recent decades, an alternative design has started being used, which, in many cases, shows an improvement in terms of accuracy compared with traditional sampling. It is called R

  20. Statistical aspects of food safety sampling.

    Science.gov (United States)

    Jongenburger, I; den Besten, H M W; Zwietering, M H

    2015-01-01

    In food safety management, sampling is an important tool for verifying control. Sampling by nature is a stochastic process. However, uncertainty regarding results is made even greater by the uneven distribution of microorganisms in a batch of food. This article reviews statistical aspects of sampling and describes the impact of distributions on the sampling results. Five different batch contamination scenarios are illustrated: a homogeneous batch, a heterogeneous batch with high- or low-level contamination, and a batch with localized high- or low-level contamination. These batch contamination scenarios showed that sampling results have to be interpreted carefully, especially when heterogeneous and localized contamination in food products is expected.