WorldWideScience

Sample records for sample holder valco

  1. Transmission electron microscope sample holder with optical features

    Science.gov (United States)

    Milas, Mirko [Port Jefferson, NY; Zhu, Yimei [Stony Brook, NY; Rameau, Jonathan David [Coram, NY

    2012-03-27

    A sample holder for holding a sample to be observed for research purposes, particularly in a transmission electron microscope (TEM), generally includes an external alignment part for directing a light beam in a predetermined beam direction, a sample holder body in optical communication with the external alignment part and a sample support member disposed at a distal end of the sample holder body opposite the external alignment part for holding a sample to be analyzed. The sample holder body defines an internal conduit for the light beam and the sample support member includes a light beam positioner for directing the light beam between the sample holder body and the sample held by the sample support member.

  2. Manipulator for rotating and translating a sample holder

    Science.gov (United States)

    van de Water, Jeroen [Breugel, NL; van den Oetelaar, Johannes [Eindhoven, NL; Wagner, Raymond [Gorinchem, NL; Slingerland, Hendrik Nicolaas [Venlo, NL; Bruggers, Jan Willem [Eindhoven, NL; Ottevanger, Adriaan Huibert Dirk [Malden, NL; Schmid, Andreas [Berkeley, CA; Olson, Eric A [Champaign, IL; Petrov, Ivan G [Champaign, IL; Donchev, Todor I [Urbana, IL; Duden, Thomas [Kensington, CA

    2011-02-08

    A manipulator for use in e.g. a Transmission Electron Microscope (TEM) is described, said manipulator capable of rotating and translating a sample holder (4). The manipulator clasps the round sample holder between two members (3A, 3B), said members mounted on actuators (2A, 2B). Moving the actuators in the same direction results in a translation of the sample holder, while moving the actuators in opposite directions results in a rotation of the sample holder.

  3. Tem holder for sample transfer under reaction conditions

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Wagner, Jakob Birkedal

    Environmental transmission electron microscopy (ETEM) studies are usually performed using conventional sample holders in a dedicated ETEM [1] or in a traditional TEM by use of a dedicated high-pressure cell sample holder [2]. In both cases, the setup defines the conditions regarding gas, pressure......]. Furthermore, dedicated transfer holders have been used to transfer catalyst samples between reactor set-ups and TEM at room temperature in inert atmosphere [5]. To take the full advantage of complementary in situ techniques, transfer under reactions conditions is essential. This study introduces the in situ...... transfer concept by use of a dedicated TEM transfer holder capable of enclosing the sample in a gaseous environment at temperatures up to approx. 900C. By oxidation and reduction experiments of Cu nanoparticles it is shown possible to keep the reaction conditions during transfer outside the microscope...

  4. 3D printing scanning electron microscopy sample holders: A quick and cost effective alternative for custom holder fabrication.

    Directory of Open Access Journals (Sweden)

    Gabriel N Meloni

    Full Text Available A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.

  5. Improved sample holders for the PMMA dosimeters

    International Nuclear Information System (INIS)

    Kobayashi, Toshikazu; Sone, Koji; Iso, Katsuaki

    1994-01-01

    PMMA dosimeters are widely used for high dose dosimetry. Dose is determined by measuring the change in optical density of the irradiated PMMA dosimeter element. Measurement precision depends on the mounting method of a dosimeter element in the sample room of a spectrophotometer. We tried to prepare three types of holders, (holders A, B and C in Figs. 1-3), according to the shape of PMMA dosimeter elements. We measured optical density of the irradiated PMMA dosimeter elements by using the three types of holders. It is revealed that the holder of the type A gives more precise results for the Red 4034 or Gammachrome YR dosimeter than that of the type B. The measurements with a spectrophotometer using the type C holder gives better results for the Red acrylic dosimeter than the case of the measurements by the exclusive reader. (author)

  6. Broadband sample holder for microwave spectroscopy of superconducting qubits

    International Nuclear Information System (INIS)

    Averkin, A. S.; Karpov, A.; Glushkov, E.; Abramov, N.; Shulga, K.; Huebner, U.; Il'ichev, E.; Ustinov, A. V.

    2014-01-01

    We present a practical design and implementation of a broadband sample holder suitable for microwave experiments with superconducting integrated circuits at millikelvin temperatures. Proposed design can be easily integrated in standard dilution cryostats, has flat pass band response in a frequency range from 0 to 32 GHz, allowing the RF testing of the samples with substrate size up to 4 × 4 mm 2 . The parasitic higher modes interference in the holder structure is analyzed and prevented via design considerations. The developed setup can be used for characterization of superconducting parametric amplifiers, bolometers, and qubits. We tested the designed sample holder by characterizing of a superconducting flux qubit at 20 mK temperature

  7. Automatic gamma radiation scanning device and feed mechanism for plural sample holders

    International Nuclear Information System (INIS)

    Byrd, W.J.

    1976-01-01

    Apparatus is disclosed for measuring the level of gamma radiation contained in a plurality of biological samples which are located on the fibrous sheet member carried by a sample holder. The apparatus is adapted to count the radiation level of the number of closely spaced samples located in rows and columns on the sheet by automatically sequencing through the individual samples within the rows and to advance the holder to bring successive rows into proximity with the detector. The detector is moved from sample to sample within the rows, although a number of detectors can be employed. A plurality of sample holders are automatically advanced to the detector. 25 claims, 5 drawing figures

  8. Sample holder for studying temperature dependent particle guiding

    International Nuclear Information System (INIS)

    Bereczky, R.J.; Toekesi, K.; Kowarik, G.; Aumayr, F.

    2011-01-01

    Complete text of publication follows. The so called guiding effect is a complex process involving the interplay of a large number of charged particles with a solid. Although many research groups joined this field and carried out various experiments with insulator capillaries many details of the interactions are still unknown. We investigated the temperature dependence of the guiding since it opens new possibilities both for a fundamental understanding of the guiding phenomenon and for applications. For the temperature dependent guiding experiments a completely new heatable sample holder was designed. We developed and built such a heatable sample holder to make accurate and reproducible studies of the temperature dependence of the ion guiding effect possible. The target holder (for an exploded view see Fig. 1) consists of two main parts, the front and the back plates. The two plates of the sample holder, which function as an oven, are made of copper. These parts surround the capillary in order to guarantee a uniform temperature along the whole tube. The temperature of the copper parts is monitored by a K-Type thermocouple. Stainless steel coaxial heaters surrounding the oven are used for heating. The heating power up to a few watts is regulated by a PID controller. Cooling of the capillary is achieved by a copper feed-through connected to a liquid nitrogen bath outside the UHV chamber. This solution allows us to change the temperature of the sample from -30 deg C up to 90 deg C. Our experiments with this newly developed temperature regulated capillary holder show that the glass temperature (i.e. conductivity) can be used to control the guiding properties of the glass capillary and adjust the conditions from guiding at room temperature to simple geometrical transmission at elevated temperatures. This holds the promise to investigate the effect of conductivity on particle transport (build-up and removal of charge patches) through capillaries in more details

  9. Towards a compact and precise sample holder for macromolecular crystallography.

    Science.gov (United States)

    Papp, Gergely; Rossi, Christopher; Janocha, Robert; Sorez, Clement; Lopez-Marrero, Marcos; Astruc, Anthony; McCarthy, Andrew; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Most of the sample holders currently used in macromolecular crystallography offer limited storage density and poor initial crystal-positioning precision upon mounting on a goniometer. This has now become a limiting factor at high-throughput beamlines, where data collection can be performed in a matter of seconds. Furthermore, this lack of precision limits the potential benefits emerging from automated harvesting systems that could provide crystal-position information which would further enhance alignment at beamlines. This situation provided the motivation for the development of a compact and precise sample holder with corresponding pucks, handling tools and robotic transfer protocols. The development process included four main phases: design, prototype manufacture, testing with a robotic sample changer and validation under real conditions on a beamline. Two sample-holder designs are proposed: NewPin and miniSPINE. They share the same robot gripper and allow the storage of 36 sample holders in uni-puck footprint-style pucks, which represents 252 samples in a dry-shipping dewar commonly used in the field. The pucks are identified with human- and machine-readable codes, as well as with radio-frequency identification (RFID) tags. NewPin offers a crystal-repositioning precision of up to 10 µm but requires a specific goniometer socket. The storage density could reach 64 samples using a special puck designed for fully robotic handling. miniSPINE is less precise but uses a goniometer mount compatible with the current SPINE standard. miniSPINE is proposed for the first implementation of the new standard, since it is easier to integrate at beamlines. An upgraded version of the SPINE sample holder with a corresponding puck named SPINEplus is also proposed in order to offer a homogenous and interoperable system. The project involved several European synchrotrons and industrial companies in the fields of consumables and sample-changer robotics. Manual handling of mini

  10. A sample holder for the study of isothermal heat of hydration of cement

    DEFF Research Database (Denmark)

    Hansen, Per Freiesleben; Jensen, Ole Mejlhede

    1998-01-01

    Different techniques for measuring heat of hydration of cement are discussed, and a sample holder designed specially for measuring isothermal heat of hydration is described. A particular characteristic of the sample holder is the vacuum mixing technique which ensures a momentary and homogeneous...

  11. A sample holder for in-house X-ray powder diffraction studies of protein powders

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl; Harris, Pernille; Ståhl, Kenny

    2011-01-01

    A sample holder for handling samples of protein for in-house X-ray powder diffraction (XRPD) analysis has been made and tested on lysozyme. The use of an integrated pinhole reduced the background, and good signal-to-noise ratios were obtained from only 7 l of sample, corresponding to approximatel...... 2-3 mg of dry protein. The sample holder is further adaptable to X-ray absorption spectroscopy (XAS) measurements. Both XRPD and XAS at the Zn K-edge were tested with hexameric Zn insulin....

  12. Evaluation of the uncertainty associated with sample holders in NAA measurements in LAN/IPEN

    Energy Technology Data Exchange (ETDEWEB)

    Zahn, Guilherme S.; Ticianelli, Regina B.; Saiki, Mitiko; Genezini, Frederico A., E-mail: ticianelli@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    In IPEN's Neutron Activation Laboratory (LAN/IPEN), thin stainless steel sample holders are used for gamma spectrometry in NAA measurements. This material is very practical, but its chemical composition may be troublesome, as it presents large amounts of elements with intermediate atomic number, with attenuation factors for low-energy gamma-rays that must not be neglected. In this study, count rates obtained using different sample holders were compared. To accomplish that, an Am-241 source, with 59-keV gamma emission, was used so that low-energy gamma attenuation differences can be determined. Moreover, in order to study the energy dependence of these differences, a Ho-166m source was also used. From these results, it was possible to analyze the experimental error associated to the variations between sample holders, with the aim of introducing an addictive term to the uncertainty analysis of comparative Neutron Activation Analysis results. (author)

  13. Breeding snow: an instrumented sample holder for simultaneous tomographic and thermal studies

    International Nuclear Information System (INIS)

    Pinzer, B; Schneebeli, M

    2009-01-01

    To study the recrystallization processes during temperature gradient metamorphism of snow, we developed a sample holder that allows applying well-defined and stable thermal gradients to a snow sample while it is scanned in an x-ray micro-tomograph. To this end, both the thermal insulation of the sample as well as image contrast and resolution of the tomography had to be optimized. We solved this conflict by using thin aluminum cylinders in combination with highly insulating foam. This design is light, does not corrupt image quality and provides very good thermal decoupling from the environment. The sample holder was instrumented to measure the effective conductivity of the snow sample and calibrated using five materials of known conductivity. Finite element simulations were consistent with the calibration measurements and gave insight into the internal temperature and heat flux fields. With this setup, geometric and thermal evolution of snow under realistic thermal boundary conditions like alternating temperature gradients can be measured

  14. Note: A scanning electron microscope sample holder for bidirectional characterization of atomic force microscope probe tips

    Energy Technology Data Exchange (ETDEWEB)

    Eisenstein, Alon; Goh, M. Cynthia [Department of Chemistry and Institute for Optical Sciences, University of Toronto, 80 St. George Street, Toronto M5S 3H6 (Canada)

    2012-03-15

    A novel sample holder that enables atomic force microscopy (AFM) tips to be mounted inside a scanning electron microscopy (SEM) for the purpose of characterizing the AFM tips is described. The holder provides quick and easy handling of tips by using a spring clip to hold them in place. The holder can accommodate two tips simultaneously in two perpendicular orientations, allowing both top and side view imaging of the tips by the SEM.

  15. A new sample holder for laser-excited pump-probe magnetic measurements on a Focus photoelectron emission microscope

    International Nuclear Information System (INIS)

    Miguel, Jorge; Bernien, Matthias; Kuch, Wolfgang; Bayer, Daniela; Aeschlimann, Martin; Sanchez-Barriga, Jaime; Kronast, Florian; Duerr, Hermann A.

    2008-01-01

    A custom-made Omicron-compatible sample holder for time-resolved photoelectron emission microscopy experiments is presented. It comprises a sample plate with four contacts that hosts a chip carrier where the semiconductor substrate is mounted. Covering the sample holder, a 6 mm diameter mask protects electrostatically the sample from the extractor lens voltage while keeping the imaging quality unperturbed. The improvements are a greater sample lifetime and the ability to withstand much higher currents in the stripline that provides the magnetic pulse to the magnetic microstructure

  16. Dose computation of Ti activated products for its qualification as a material for the sample holder in FBTR

    International Nuclear Information System (INIS)

    Ashok Kumar, G.V.S.; Kumar, R.; Venkatasubramani, C.R.; Acharya, R.; Reddy, A.V.R.

    2014-01-01

    Development of a Fast flux experimental facility with a sample holder facility in FBTR has been envisaged to carry out the studies on i) fast neutron activation analysis and ii) fission studies. This paper describes the facility in detail and dose computations that are to be generated due to long irradiation of the material of the sample holder i.e. titanium. (author)

  17. Practical aspects of the use of the X(2) holder for HRTEM-quality TEM sample preparation by FIB.

    Science.gov (United States)

    van Mierlo, Willem; Geiger, Dorin; Robins, Alan; Stumpf, Matthias; Ray, Mary Louise; Fischione, Paul; Kaiser, Ute

    2014-12-01

    The X(2) holder enables the effective production of thin, electron transparent samples for high-resolution transmission electron microscopy (HRTEM). Improvements to the X(2) holder for high-quality transmission electron microscopy (TEM) sample preparation are presented in this paper. We discuss the influence of backscattered electrons (BSE) from the sample holder in determining the lamella thickness in situ and demonstrate that a significant improvement in thickness determination can be achieved by comparatively simple means using the relative BSE intensity. We show (using Monte Carlo simulations) that by taking into account the finite collection angle of the electron backscatter detector, an approximately 20% underestimation of the lamella thickness in a silicon sample can be avoided. However, a correct thickness determination for light-element lamellas still remains a problem with the backscatter method; we introduce a more accurate method using the energy dispersive X-ray spectroscopy (EDX) signal for in situ thickness determination. Finally, we demonstrate how to produce a thin lamella with a nearly damage-free surface using the X(2) holder in combination with sub-kV polishing in the Fischione Instruments׳ NanoMill(®) TEM specimen preparation system. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Bacteriological, biochemical, and immunological modifications in human colostrum after Holder pasteurisation.

    Science.gov (United States)

    Espinosa-Martos, I; Montilla, A; de Segura, A Gómez; Escuder, D; Bustos, G; Pallás, C; Rodríguez, J M; Corzo, N; Fernández, L

    2013-05-01

    The objective of this work was to evaluate the effect of Holder pasteurisation of human colostrum on a variety of microbiological, biochemical, and immunological parameters. Colostrum samples from 10 donors, and 8 samples of mature milk used as controls, were heated at 62.5°C for 30 minutes. Bacterial counts and the concentration of furosine, lactose, myoinositol, glucose, lactulose, cytokines, and immunoglobulins were determined before and after the heat treatment. Mean bacterial counts in nonpasteurised colostrum samples oscillated between 2.72 and 4.13 log10 colony-forming units per millilitre in the agar media tested. Holder pasteurisation led to the destruction of the bacteria originally present in the samples. Furosine was detected in all samples before pasteurisation and increased significantly after the heat treatment (from 6.60 to 20.59 mg/100 g protein). Lactulose content was below the detection limit in nonpasteurised colostrum, but it was detected in all samples and quantified in 7 of them (from 10.68 to 38.02 mg/L) after Holder pasteurisation. Lactose, glucose, and myoinositol concentrations did not change after Holder pasteurisation. The concentrations of most cytokines and immunoglobulins were significantly higher in colostrum than in mature milk samples. Immunoglobulin content, both in colostrum and in milk samples, was reduced during pasteurisation, whereas, among cytokines, only macrophage inflammatory protein-1β, interleukin-7, and granulocyte-macrophage-colony-stimulating factor concentrations were affected by this heat treatment. Lactulose and furosine content could be used as heat treatment indicators in colostrum samples. Holder pasteurisation modified the immunological profile of both colostrum and mature milk.

  19. Preparation and Loading Process of Single Crystalline Samples into a Gas Environmental Cell Holder for In Situ Atomic Resolution Scanning Transmission Electron Microscopic Observation.

    Science.gov (United States)

    Straubinger, Rainer; Beyer, Andreas; Volz, Kerstin

    2016-06-01

    A reproducible way to transfer a single crystalline sample into a gas environmental cell holder for in situ transmission electron microscopic (TEM) analysis is shown in this study. As in situ holders have only single-tilt capability, it is necessary to prepare the sample precisely along a specific zone axis. This can be achieved by a very accurate focused ion beam lift-out preparation. We show a step-by-step procedure to prepare the sample and transfer it into the gas environmental cell. The sample material is a GaP/Ga(NAsP)/GaP multi-quantum well structure on Si. Scanning TEM observations prove that it is possible to achieve atomic resolution at very high temperatures in a nitrogen environment of 100,000 Pa.

  20. Acceptance Testing of Thermoluminescent Dosimeter Holders.

    Science.gov (United States)

    Romanyukha, Alexander; Grypp, Matthew D; Sharp, Thad J; DiRito, John N; Nelson, Martin E; Mavrogianis, Stanley T; Torres, Jeancarlo; Benevides, Luis A

    2018-05-01

    The U.S. Navy uses the Harshaw 8840/8841 dosimetric (DT-702/PD) system, which employs LiF:Mg,Cu,P thermoluminescent dosimeters (TLDs), developed and produced by Thermo Fisher Scientific (TFS). The dosimeter consists of four LiF:Mg,Cu,P elements, mounted in Teflon® on an aluminum card and placed in a plastic holder. The holder contains a unique filter for each chip made of copper, acrylonitrile butadiene styrene (ABS), Mylar®, and tin. For accredited dosimetry labs, the ISO/IEC 17025:2005(E) requires an acceptance procedure for all new equipment. The Naval Dosimetry Center (NDC) has developed and tested a new non-destructive procedure, which enables the verification and the evaluation of embedded filters in the holders. Testing is based on attenuation measurements of low-energy radiation transmitted through each filter in a representative sample group of holders to verify that the correct filter type and thickness are present. The measured response ratios are then compared with the expected response ratios. In addition, each element's measured response is compared to the mean response of the group. The test was designed and tested to identify significant nonconformities, such as missing copper or tin filters, double copper or double tin filters, or other nonconformities that may impact TLD response ratios. During the implementation of the developed procedure, testing revealed a holder with a double copper filter. To complete the evaluation, the impact of the nonconformities on proficiency testing was examined. The evaluation revealed failures in proficiency testing categories III and IV when these dosimeters were irradiated to high-energy betas.

  1. ADJUSTABLE CHIP HOLDER

    DEFF Research Database (Denmark)

    2009-01-01

    An adjustable microchip holder for holding a microchip is provided having a plurality of displaceable interconnection pads for connecting the connection holes of a microchip with one or more external devices or equipment. The adjustable microchip holder can fit different sizes of microchips...

  2. Preset pivotal tool holder

    Science.gov (United States)

    Asmanes, Charles

    1979-01-01

    A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.

  3. Quality control and enhancement of microwelds for Ir-192 sample holders

    International Nuclear Information System (INIS)

    Lopez, Alcides; Medina, Max; Cavero, Luis

    2013-01-01

    This study shows the micro quality results of tungsten inert gas welds on stainless steel AISI 304 of 5 sample holders for 30 discs by 3 mm diameter and 0.5 mm thick of Ir-192 sources produced in the Radioisotope Production Plant (RPP) of IPEN, generally used in industrial gammagraphy. Macrographic and conventional metallographic analysis were performed to measure the amplitude, thickness and centering parameters of the weld bead, centered data have helped to determine the parameters for welds with good quality, showing defects due to the misaligned glass lens, low magnification image and high visual angle of incidence across the 200 mm security leaded glass giving a low quality weld image due to the low magnification, large chromatic aberration resulting in a weld outside the seam, this problem was solved by changing the old optical visualization system by an external telescope specially designed for this purpose and raising the workbench so that the optical telescope axis and the weld are horizontally, achieving more rapid processes, reliable and reproducible, this new system has proved more convenient, reliable and reproducible. (authors).

  4. An X-ray diffractometer specimen holder for use with reactive and toxic materials

    International Nuclear Information System (INIS)

    Huyton, A.; Munden, A.B.

    1979-04-01

    An X-ray diffractometer specimen holder has been designed for analysis of reactive sodium compounds which will satisfactorily seal the sample from the atmosphere. The holder can be readily filled in a glove-box and is easily transported for mounting on a vertical Philips PW 1051 X-ray diffractometer. It is considered that this holder could also be applied to a wide range of other reactive and toxic materials, e.g. plutonium or its compounds. (author)

  5. Ebola Virus and Marburg Virus in Human Milk Are Inactivated by Holder Pasteurization.

    Science.gov (United States)

    Hamilton Spence, Erin; Huff, Monica; Shattuck, Karen; Vickers, Amy; Yun, Nadezda; Paessler, Slobodan

    2017-05-01

    Potential donors of human milk are screened for Ebola virus (EBOV) using standard questions, but testing for EBOV and Marburg virus (MARV) is not part of routine serological testing performed by milk banks. Research aim: This study tested the hypothesis that EBOV would be inactivated in donor human milk (DHM) by standard pasteurization techniques (Holder) used in all North American nonprofit milk banks. Milk samples were obtained from a nonprofit milk bank. They were inoculated with EBOV (Zaire strain) and MARV (Angola strain) and processed by standard Holder pasteurization technique. Plaque assays for EBOV and MARV were performed to detect the presence of virus after pasteurization. Neither EBOV nor MARV was detectable by viral plaque assay in DHM or culture media samples, which were pasteurized by the Holder process. EBOV and MARV are safely inactivated in human milk by standard Holder pasteurization technique. Screening for EBOV or MARV beyond questionnaire and self-deferral is not needed to ensure safety of DHM for high-risk infants.

  6. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    Science.gov (United States)

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  7. 19 CFR 10.7 - Substantial containers or holders.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Substantial containers or holders. 10.7 Section 10... Exported and Returned § 10.7 Substantial containers or holders. (a) Substantial containers or holders... domestic products exported and returned. When such containers or holders are imported not containing or...

  8. Considerations on sample holder design and custom-made non-polarizable electrodes for Spectral Induced Polarization measurements on unsaturated soils

    Science.gov (United States)

    Kaouane, C.; Chouteau, M. C.; Fauchard, C.; Cote, P.

    2014-12-01

    Spectral Induced Polarization (SIP) is a geophysical method sensitive to water content, saturation and grain size distribution. It could be used as an alternative to nuclear probes to assess the compaction of soils in road works. To evaluate the potential of SIP as a practical tool, we designed an experiment for complex conductivity measurements on unsaturated soil samples.Literature presents a large variety of sample holders and designs, each depending on the context. Although we might find some precise description about the sample holder, exact replication is not always possible. Furthermore, the potential measurements are often done using custom-made Ag/AgCl electrodes and very few indications are given on their reliability with time and temperature. Our objective is to perform complex conductivity measurements on soil samples compacted in a PVC cylindrical mould (10 cm-long, 5 cm-diameter) according to geotechnical standards. To expect homogeneous current density, electrical current is transmitted through the sample via chambers filled with agar gel. Agar gel is a good non-polarizable conductor within the frequency range (1 mHz -20kHz). Its electrical properties are slightly known. We measured increasing of agar-agar electrical conductivity in time. We modelled the influence of this variation on the measurement. If the electrodes are located on the sample, it is minimized. Because of the dimensions at stake and the need for simple design, potential electrodes are located outside the sample, hence the gel contributes to the measurements. Since the gel is fairly conductive, we expect to overestimate the sample conductivity. Potential electrodes are non-polarizable Ag/AgCl electrodes. To avoid any leakage, the KCl solution in the electrodes is replaced by saturated KCl-agar gel. These electrodes are low cost and show a low, stable, self-potential (<1mV). In addition, the technique of making electrode can be easily reproduced and storage and maintenance are simple

  9. Diffeomorphisms Holder conjugate to Anosov diffeomorphisms

    OpenAIRE

    Gogolev, Andrey

    2008-01-01

    We show by means of a counterexample that a $C^{1+Lip}$ diffeomorphism Holder conjugate to an Anosov diffeomorphism is not necessarily Anosov. The counterexample can bear higher smoothness up to $C^3$. Also we include a result from the 2006 Ph.D. thesis of T. Fisher: a $C^{1+Lip}$ diffeomorphism Holder conjugate to an Anosov diffeomorphism is Anosov itself provided that Holder exponents of the conjugacy and its inverse are sufficiently large.

  10. National Recordal System IK holder catalogue process

    CSIR Research Space (South Africa)

    Pretorius, R

    2012-10-01

    Full Text Available good, based on IK.? Subsequently, the South African Department of Science and Technology (DST) created a National Indigenous Knowledge Systems Office (NIKSO) that is taking the lead on interfacing IKS with other recognised knowledge holders... is to illustrate the South African National Recordal Systems (NRS) process whereby Indigenous Knowledge (IK) holder?s information is captured in a registry, as specified in South Africa?s Indigenous Knowledge Systems (IKS) Policy, through an IK cataloguing...

  11. Successive measurements of streaming potential and electroosmotic pressure with the same core-holder

    Science.gov (United States)

    Yin, Chenggang; Hu, Hengshan; Yu, Chunhao; Wang, Jun

    2018-05-01

    Successive measurements of the streaming potential and electroosmotic pressure of each core sample are important for understanding the mechanisms of electrokinetic effects. In previous studies, one plug of the core-holder needs to be replaced in these two experiments, which causes the change of the fluid parameters and the boundary conditions in the core. We design a new core-holder to permit successive experiments without plug replacement, which ensures the consistency of the measurement environment. A two-direction harmonic pressure-driving source is accordingly designed. Using this new equipment, electrokinetic experiments conducted ten core samples at 0.4 mol/L NaCl solution. The results show good agreement between the electrokinetically deduced permeability and premeasured gas permeability. For high salinity saturated samples, the permeability can be inverted from electroosmotic effect instead of the streaming potential.

  12. Harmonising and Matching IPR Holders at IP Australia

    OpenAIRE

    T’Mir D. Julius; Gaétan de Rassenfosse

    2014-01-01

    This document describes the methodology developed by the Melbourne Institute to: (i) harmonise holders of intellectual property rights (IPRs) at IP Australia (applications for patent, designs, trademarks and plant breeder’s rights); (ii) match Australian IPRs holders to the Australian business register; (iii) identify the ultimate owners within Australia; and (iv) identify which holders are small and medium size enterprises.

  13. Development and Application of a Sample Holder for In Situ Gaseous TEM Studies of Membrane Electrode Assemblies for Polymer Electrolyte Fuel Cells.

    Science.gov (United States)

    Kamino, Takeo; Yaguchi, Toshie; Shimizu, Takahiro

    2017-10-01

    Polymer electrolyte fuel cells hold great potential for stationary and mobile applications due to high power density and low operating temperature. However, the structural changes during electrochemical reactions are not well understood. In this article, we detail the development of the sample holder equipped with gas injectors and electric conductors and its application to a membrane electrode assembly of a polymer electrolyte fuel cell. Hydrogen and oxygen gases were simultaneously sprayed on the surfaces of the anode and cathode catalysts of the membrane electrode assembly sample, respectively, and observation of the structural changes in the catalysts were simultaneously carried out along with measurement of the generated voltages.

  14. Stability of Cortisol and Cortisone in Human Breast Milk During Holder Pasteurization.

    Science.gov (United States)

    van der Voorn, Bibian; de Waard, Marita; Dijkstra, Lisette R; Heijboer, Annemieke C; Rotteveel, Joost; van Goudoever, Johannes B; Finken, Martijn J J

    2017-12-01

    Human donor milk is the feeding of choice for preterm infants, when own mother's milk is not available. Holder pasteurization is necessary to secure the safety of donor milk, although it can affect milk quality by reduction of nutritional and bioactive components. Recently, research has focused on the potential role of breast milk glucocorticoids for infant development. At this moment, it is unknown whether pasteurization affects milk glucocorticoid levels. Therefore, we assessed whether Holder pasteurization, the most frequently used method nowadays, reduces breast milk cortisol and cortisone levels, using breast milk samples from 30 women who delivered at term. We found tight correlations between pre- and postpasteurization levels of cortisol (R = 0.99) and cortisone (R = 0.98), and good agreement in Passing and Bablok regression analysis. In conclusion, cortisol and cortisone in human term breast milk are not significantly affected by Holder pasteurization.

  15. Head-positioning scintillation camera and head holder therefor

    International Nuclear Information System (INIS)

    Kay, T.D.

    1976-01-01

    A holder for immobilizing the head of a patient undergoing a vertex brain scan by a Gamma Scintillation Camera is described. The holder has a uniquely designed shape capable of comfortably supporting the head. In addition, this holder can be both adjustably and removably utilized in combination with the scintillation camera so as to enable the brain scan operation to take place while the patient is in the seated position

  16. Effects of Holder pasteurization on the protein profile of human milk.

    Science.gov (United States)

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Cavaletto, Maria; Spertino, Stefano; Icardi, Sara; Tortone, Claudia; Visser, Gerard H A; Gazzolo, Diego

    2016-04-07

    The most widespread method for the treatment of donor milk is the Holder pasteurization (HoP). The available literature data show that HoP may cause degradation of some bioactive components. The aim of this study was to determine the effect of HoP on the protein profile of human milk (HM) using a GeLC-MS method, a proteomic approach and a promising technique able to offer a qualitative HM protein profile. HM samples were collected by standardized methods from 20 mothers carrying both preterm and term newborns. A aliquot of each sample was immediately frozen at -80 °C, whilst another one was Holder pasteurized and then frozen. All samples were then analyzed by GeLC-MS. The protein bands of interest were excised from the gel, digested with trypsin and identified by nano-HPLC-MS/MS analysis. The protein profile before and after HoP showed qualitative differences only in 6 samples out of 20, while in the remaining 14 no detectable differences were found. The differences interested only colostrums and transitional milk samples and regarded the decrease of the electrophoretic bands corresponding to alpha and beta-casein, tenascin, lactoferrin and immunoglobulin. In the majority of samples, HoP did not cause any modification, thereby preserving the biological activity of HM proteins.

  17. The effectiveness of an endotracheal tube holder

    Directory of Open Access Journals (Sweden)

    Byung Gun Lim

    2016-01-01

    Full Text Available The security of the endotracheal tube (ETT is important in the anesthesia and intensive care settings. Recently, an ETT holder instead of an adhesive tape is frequently used to provide the fixation of the ETT. There are some studies that focused on the effectiveness of the ETT holder in preventing displacement of ETT compared to an adhesive tape (1, 2. I have experienced the use of an ETT holder (E-holder, KS medical, Bucheon, Korea in many different anesthesia settings and recognized its usefulness and convenience other than ETT security in the following specific settings.  Firstly, the ETT holder is definitely effective for patients undergoing procedures that frequently require the adjustment of ETT (or double lumen tube location including thoracic surgery. The location of double lumen tube needed for lung separation can be modified for effective ventilation during anesthetic induction or surgery, and after position changes. The tube can be easily relocated to the proper place for lung separation and effective ventilation by unlocking/relocking the button of the ETT holder under flexible bronchoscopic guidance (Fig. 1A, which can facilitate the operative procedure to be performed easily and quickly. Secondly, the ETT holder can be useful in procedures requiring the prone position (3. Especially, it is useful in all circumstances requiring the adjustment of ETT in the prone position. For instance, it is definitely useful for patients with Duchene muscular dystrophy undergoing scoliosis surgery under prone position. Adolescent patients with Duchene muscular dystrophy frequently have tracheobronchial malacia. If so, the airway pressure can be elevated due to the narrowing of the lesion of malacia when changed to the prone position (4. To overcome this problem, a reinforced ETT should be relocated so that it passes the narrowed tracheal lesion under flexible bronchoscopic guidance (Fig. 1B. However, the approach for this management is somewhat

  18. Apparatus for sectioning demountable semiconductor samples

    Science.gov (United States)

    Sopori, B.L.; Wolf, A.

    1984-01-01

    Apparatus for use during polishing and sectioning operations of a ribbon sample is described. The sample holder includes a cylinder having an axially extending sample cavity terminated in a first funnel-shaped opening and a second slot-like opening. A spring-loaded pressure plunger is located adjacent the second opening of the sample cavity for frictional engagement of the sample cavity. A heat softenable molding medium is inserted in the funnel-shaped opening, to surround the sample. After polishing, the heater is energized to allow draining of the molding medium from the sample cavity. During manual polishing, the second end of the sample holder is inserted in a support ring which provides mechanical support as well as alignment of the sample holder during polishing. A gauge block for measuring the protrusion of a sample beyond the second wall of the holder is also disclosed.

  19. Low conductive support for thermal insulation of a sample holder of a variable temperature scanning tunneling microscope.

    Science.gov (United States)

    Hanzelka, Pavel; Vonka, Jakub; Musilova, Vera

    2013-08-01

    We have designed a supporting system to fix a sample holder of a scanning tunneling microscope in an UHV chamber at room temperature. The microscope will operate down to a temperature of 20 K. Low thermal conductance, high mechanical stiffness, and small dimensions are the main features of the supporting system. Three sets of four glass balls placed in vertices of a tetrahedron are used for thermal insulation based on small contact areas between the glass balls. We have analyzed the thermal conductivity of the contacts between the balls mutually and between a ball and a metallic plate while the results have been applied to the entire support. The calculation based on a simple model of the setup has been verified with some experimental measurements. In comparison with other feasible supporting structures, the designed support has the lowest thermal conductance.

  20. 38 CFR 36.4341 - Death or insolvency of holder.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Death or insolvency of... Death or insolvency of holder. (a) Immediately upon the death of the holder and without the necessity of... applicable in the event of: (1) Insolvency of holder; (2) Initiation of any bankruptcy or reorganization, or...

  1. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  2. A cylindrical specimen holder for electron cryo-tomography

    International Nuclear Information System (INIS)

    Palmer, Colin M.; Löwe, Jan

    2014-01-01

    The use of slab-like flat specimens for electron cryo-tomography restricts the range of viewing angles that can be used. This leads to the “missing wedge” problem, which causes artefacts and anisotropic resolution in reconstructed tomograms. Cylindrical specimens provide a way to eliminate the problem, since they allow imaging from a full range of viewing angles around the tilt axis. Such specimens have been used before for tomography of radiation-insensitive samples at room temperature, but never for frozen-hydrated specimens. Here, we demonstrate the use of thin-walled carbon tubes as specimen holders, allowing the preparation of cylindrical frozen-hydrated samples of ribosomes, liposomes and whole bacterial cells. Images acquired from these cylinders have equal quality at all viewing angles, and the accessible tilt range is restricted only by the physical limits of the microscope. Tomographic reconstructions of these specimens demonstrate that the effects of the missing wedge are substantially reduced, and could be completely eliminated if a full tilt range was used. The overall quality of these tomograms is still lower than that obtained by existing methods, but improvements are likely in future. - Highlights: • The missing wedge is a serious problem for electron cryo-tomography. • Cylindrical specimens allow the missing wedge to be eliminated. • Carbon nanopipettes can be used as cylindrical holders for tomography of frozen-hydrated specimens. • Cryo-tomography of cylindrical biological samples demonstrates a reduction of deleterious effects associated with the missing wedge

  3. Ergonomic design and evaluation of a diagnostic ultrasound transducer holder.

    Science.gov (United States)

    Ghasemi, Mohamad Sadegh; Hosseinzadeh, Payam; Zamani, Farhad; Ahmadpoor, Hossein; Dehghan, Naser

    2017-12-01

    Work-related musculoskeletal disorders (WMSDs) are injuries and disorders that affect the body's movement and musculoskeletal system. Awkward postures represent one of the major ergonomic risk factors that cause WMSDs among sonographers while working with an ultrasound transducer. This study aimed to design and evaluate a new holder for the ultrasound transducer. In the first phase a new holder was designed for the transducer, considering design principles. Evaluation of the new holder was then carried out by electrogoniometry and a locally perceived discomfort (LPD) scale. The application of design principles to the new holder resulted in an improvement of wrist posture and comfort. Wrist angles in extension, flexion, radial deviation and ulnar deviation were lower with utilization of the new holder. The severity of discomfort based on the LPD method in the two modes of work with and without the new holder was reported with values of 1.3 and 1.8, respectively (p ergonomics design principles was effective in minimizing wrist deviation and increasing comfort while working with the new holder.

  4. Holder pasteurization affects S100B concentrations in human milk.

    Science.gov (United States)

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Li Volti, Giovanni; Galvano, Fabio; Visser, Gerard H A; Gazzolo, Diego

    2018-02-01

    Donor milk (DM) represents an important nutrition source for high-risk newborns. Holder pasteurization (HoP) is the most recommended procedure for DM treatment, providing a good compromise between microbiological safety and biological quality. HoP was previously shown to affect DM cytokines, growth factors and hormones levels, whilst no data concerning the possible effects of HoP on neurobiomarkers (NB) are available. Therefore, our study investigated whether the concentration in DM of a well-known NB involved in brain development/damage, namely S100B, changes due to HoP. We conducted a pretest-test study in 11 mothers, whose DM samples were sub-divided into two parts: the first was immediately frozen (-80 °C); the second was pasteurized with Holder method before freezing. S100B DM levels were measured using a commercially available immunoluminometric assay. S100B protein was detected in all milk samples. Results showed significant differences between groups (p pasteurization stresses and the need to develop new storage techniques to preserve the biological quality of human milk.

  5. 12 CFR 569.3 - Holders of proxies.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Holders of proxies. 569.3 Section 569.3 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY PROXIES § 569.3 Holders of proxies. No proxy of a mutual savings association with a term greater than eleven months or solicited at...

  6. Zaria Universal Oxygenator Holder phase I

    Directory of Open Access Journals (Sweden)

    Sunday Adoga Edaigbini

    2014-01-01

    Full Text Available Introduction: The conduct of cardiopulmonary bypass surgery requires the use of equipment and devices like the oxygenator. The oxygenator comes in different makes and each manufacturer customizes the carrier or ′holder′ of this device specific to their design. Aim: This paper presents an innovation designed to overcome the need to purchase a different holder for every oxygenator thereby cutting the cost. Materials and Methods: A sheet of iron measuring 1.9 cm (width × 0.1 cm (thickness was used to design the holder circular main frame. Another sheet measuring 2 cm (width × 0.6 cm (thickness × 24 cm (length was used to construct a V-shaped handle with the arms of the V attached to the main frame 7 cm apart. At the narrow base of the handle is a latch requiring two 13-gauge screws to attach the holder to the heart-lung machine. Within the circumference of the main frame are four T-shaped side arms which grip the oxygenator; located at 2, 5, 7 and 11 O′clock positions. The stem of the T consist of a 0.6 cm (thickness × 13 cm (length rod drilled through the main frame. The cross of the T consists of variable lengths of the same sheet as the mainframe attached to the stem by a screw mechanism. At the base of the T, is attached a circular handle (4 cm in diameter made of 0.4 cm iron rod. Result: An oxygenator holder which weighs 1.75 kg with a total length of 54 cm (the diameter of the mainframe is 30 cm. Its advantages include (i affordability, (ii materials are locally accessible, (iii versatility (iv reproducibility. The disadvantages include, (i it requires some time to fit, (ii caution is required in fitting the oxygenator to avoid breakage, (iii a spanner is required to lock the latch. Conclusion: The concept of a universal holder is pertinent, especially in resource poor environments to avoid purchasing a new holder whenever the usual oxygenator common to the centre is unavailable. This device is amenable to further modifications to

  7. Lexan Linear Shaped Charge Holder with Magnets and Backing Plate

    Science.gov (United States)

    Maples, Matthew W.; Dutton, Maureen L.; Hacker, Scott C.; Dean, Richard J.; Kidd, Nicholas; Long, Chris; Hicks, Robert C.

    2013-01-01

    A method was developed for cutting a fabric structural member in an inflatable module, without damaging the internal structure of the module, using linear shaped charge. Lexan and magnets are used in a charge holder to precisely position the linear shaped charge over the desired cut area. Two types of charge holders have been designed, each with its own backing plate. One holder cuts fabric straps in the vertical configuration, and the other charge holder cuts fabric straps in the horizontal configuration.

  8. Influence of endodontic instrument-holder on sterilization efficacy. A pilot in-vitro study.

    Directory of Open Access Journals (Sweden)

    Angelo Carrizo

    2013-08-01

    Full Text Available Infection control is crucial in dentistry and various methods have been designed to assure its efficacy. However, little information exists regarding the influence it could have the instrument-holder of endodontic files. The aim of this research was to determine the influence of three instruments-holders on sterilization efficacy of endodontic files. Methods: A pilot in-vitro study. 60 endodontic files were contaminated by biomechanical preparation of extracted molars with periapical abscess, then processed according to the standard washing method. The endodontic files were divided into 3 groups (n=20 and assigned to 3 instrument-holders: Metallic box (MB, surgical gauze (SG and synthetic sponge (SS. Then, the files were packaged and sterilized by autoclaving (134°C/45min. Microbiological culture was performed in thioglycolate solution for each endodontic file (37ºC/5days. Results: The overall sterilization efficacy was 91.7%, 80% for MB, 100% for SS, and 95% for SG, with no statistically significant differences (p=0.06 between the groups. Conclusions: The lack of differences in the efficacy of sterilization may be due to the reduced sample; therefore, a full-size study is necessary to confirm this outcomes. The results of this study discourage the use of the MB as instrument-holder until a full-size study can confirm this data.

  9. Knife - Holders in Ancient Egyptian Tombs (Religious and Artistic Study

    Directory of Open Access Journals (Sweden)

    dr.Rasha Omran

    2015-01-01

    Full Text Available Studying ancient Egyptian tombs have long been an important source of information regarding many aspects of Egyptian religion. Walls of New Kingdom tombs are often decorated with plenty of painted religious scenes. While they were primarily private structures containing images selected by the person who expected to be housed there for eternity, the funerary monuments also reflect religious beliefs. While numerous researches focused on many of the religious scenes depicted on the walls of ancient Egyptian tombs, no one focused on the knife - holders' scenes. Hence, the current study focused on knife - holders scenes depicted on the walls of both royal and private tombs dating back to the New Kingdom at Thebes. The current study was undertaken to shed light on the meaning and the function of knife in Ancient Egypt. To study the role of the knife-holders in Ancient Egypt. To spot light on the actions and behaviors and locations of the knife-holders in Ancient Egyptian civilization. To spot light on the representations of the knife-holders on the walls of the ancient Egyptians tombs in the Valley of the Kings and Valley of the Queens as well as the private tombs at western Thebes. To focus on the shapes and positions of the Knife-holders in Ancient Egypt. To explain the difference between Knife - Holders and Demons. To achieve the objectives of the study, the required data were collected from periodicals, references presenting Knife Holders scenes. Preserving the scenes of knife - holders on the walls of the royal tombs in the Valley of the Kings and Valley of the Queens dating back to the New Kingdom as well as the private tombs at western Thebes that contributed to the interpretation of all the data gathered from literature. The preliminary results indicated that the term (Knife-Holders is an expression which indicates to tomb-guardians, demons or minor divinities. These minor deities were subordinate to the major gods and goddesses. They

  10. Sample taking device for toxic and/or radioactive substances

    International Nuclear Information System (INIS)

    Finsterwalder, L.; Zeh, H.; Schaarschmidt, U.

    1979-01-01

    An apparatus for taking samples of toxic and/or radioactive liquid substances by introducing such substances into sample vessels includes a holder for holding such a vessel, at least one needle head filling system composed of upwardly pointing hollow needles for introducing a sample of one such substance into such a vessel at a filling position, and inlet and outlet conduits for pneumatically conveying vessels to or from the holder at a transfer position. The holder is composed of a turntable having a sleeve for accommodating such vessel and is mounted to undergo rotary movement to convey a sample vessel held in the sleeve between the filling and transfer positions. The apparatus further includes a stand supporting the filling system below the holder and a lifting device connected for imparting a translational movement to the holder to bring a vessel in the holder to operative association with the filling system. The lifting device is arranged so that the translational movement which it produces is independent of the rotary movement of the turntable

  11. Social Perception of Hydrogen Technologies: The View of Spanish Stake holders

    International Nuclear Information System (INIS)

    Ferri Anglada, S.

    2013-01-01

    This technical report presents an overview of the social perception and vision of a sample of Spanish stake holders on hydrogen technologies. The study is based on the implementation of a survey, combining both quantitative and qualitative data. An ad hoc electronic survey was design to collect views and perceptions on several key factors regarding this innovative energy alternative. The group of experts participating (N=130) in the study, comes mainly from research centers, universities and private companies. The survey addresses three major themes: expert views, social acceptability, and contextual factors of hydrogen technologies. The aim is to capture both the current and the future scene as viewed by the experts on hydrogen technologies, identifying key factors in terms of changes, uncertainties, obstacles and opportunities. The objective is to identify potential key features for the introduction, development, promotion, implementation, and large-scale deployment of a highly successful energy proposal in countries such as Iceland, one of the pioneers in base its economy on hydrogen technologies. To conclude, this report illustrates the positive engagement of a sample of Spanish stake holders towards hydrogen technologies that may prove vital in the transition towards the Hydrogen Economy in Spain. (Author)

  12. Improvements in appliance holders

    International Nuclear Information System (INIS)

    Chapman, J.E.

    1977-01-01

    Reference is made to appliance holders for locating tools, instruments, etc. in operative relationship to workpieces and accessible through passageways of restricted transverse dimensions. The appliance holder described comprises an elongated external frame provided with transversely, outwardly expanding frictional gripping means in two longitudinally spaced sets and with a ring of spur teeth. An inner elongated frame is held within the external frame in two longitudinally spaced rotary bearings and carries a spur wheel which engages the ring of the spur teeth. A motor is arranged to rotate the spur wheel and hence the inner frame in relation to the external frame. A carriage is carried by the inner frame, longitudinally movable by a motor in relation thereto, and a further carriage is mounted on this first carriage. This second cariage is transversely movable in relation to the inner frame and is provided with a face plate for attachment of tools, instruments, etc. A motor is mounted on the first carriage for moving the second carriage. (U.K.)

  13. 30 CFR 250.1010 - General requirements for pipeline right-of-way holders.

    Science.gov (United States)

    2010-07-01

    ... United States or its lessees or right-of-way holders, as the case may be, the full value of all damages...). The right-of-way holder shall make available all records relative to the design, construction... site. Furthermore, the holder is responsible for accidents or damages which might occur as a result of...

  14. Studies and developments for the analysis of products of nuclear reprocessing plants with the help of the X-ray fluorescence analysis on totally reflecting sample holders (TXRF)

    International Nuclear Information System (INIS)

    Diercks, H.; Eggers, I.; Gibau, F.; Haarich, M.; Hastenteufel, S.; Haurand, M.; Knoechel, A.; Salow, H.

    1990-01-01

    Studies with inactive and active simulates of products of nuclear reprocessing plants show the suitability of the X-Ray Fluorescence Analysis on Totally Reflecting Sample Holders (TXRF), to detect the available elements simultaneously by direct measurements of specially prepared thin samples. High dilution enables in the most cases, to avoid working in hot cells and to carry out the analysis in glove boxes. The analysis of uranium products and great amounts of matrix elements containing solutions like LAW and MAW demands the separation of the matrix elements before TXRF measurement. Procedures for this task have been developed. The potential of the new analytical procedure was demonstrated by the analysis of two samples of highly diluted high active wastes. (orig.) With 65 refs., 20 tabs., 81 figs [de

  15. Multilevel stake holder consensus building in radioactive waste management

    International Nuclear Information System (INIS)

    Dreimanis, Andrejs

    2008-01-01

    Full text: The increased demand of our society to its quality of life, global security and environmental safety as well as to observing a basic ethical principle of equity have advanced our attitude towards the recent proposals to develop shared multinational projects in the use of nuclear energy technologies, in particular, to: a) Siting of shared deep repositories for high-level radioactive waste (RW) and spent nuclear fuel safe disposal. In turn, arrangement of multinational facilities requires to gain more complex consensus between all involved parties. Method: We propose an interdisciplinary synergetic approach to multilevel consensus building for siting and construction of shared multinational repositories for RW deep disposal, based on self-organization (SO) of various stake holders, chaos and fuzziness concepts as well as Ashby principle of requisite variety. In the siting of a multi-national repository there appears an essential novel component of stake holder consensus building, namely: to reach consent - political, social, economic, ecological - among international partners, in addition to solving the whole set of intra-national consensus building items. An entire partnering country is considered as a national stake holder, represented by the national government, being faced to simultaneous seeking an upward (international) and a downward (intra-national) consensus in a psychologically stressed environment, having possibly diverse political, economic and social interests. Main Results: Following inferences about building of multilevel consensus are developed: 1) The basis of synergetic approach to stake holder interaction - informational SO, by forming a knowledge-creating stake holder community via cooperation and competition among individuals, public bodies/groups, companies, institutions; 2) Building of international stake holder consensus could be promoted by activating and diversifying multilateral interactions between intra- and international stake

  16. Freeze Protection in Gas Holders

    DEFF Research Database (Denmark)

    Hjorth, Poul G.; Duursma, Gail

    In cold weather, the water seals of gasholders need protection from freez- ing to avoid compromising the seal. These holders have a large reservoir of “tank water” at the base which is below ground. At present freeze- protection is achieved by external heating of the seal water which...

  17. A triple axes multiple target holder assembly

    International Nuclear Information System (INIS)

    Tribedi, L.C.; Narvekar, S.D.; Pillay, R.G.; Tandon, P.N.

    1993-01-01

    We have designed and fabricated a rotatable target holder assembly capable of accommodating 27 targets. The target foils are mounted along two concentric circles on a ss wheel. On the outer circle 18 targets can be mounted each 20deg apart, and on the inner circle the remaining targets are positioned each 40deg apart. The self supporting or carbon backed targets are mounted on thin frames and are placed concentrically at the targets are mounted on thin frames and are placed concentrically at the target position on the wheel. Three degrees of freedom are provided to the target holder assembly. (author). 1 fig

  18. Research on scholarships holders who studied abroad and returned to Serbia

    Directory of Open Access Journals (Sweden)

    Nena A. Vasojevic

    2017-10-01

    Full Text Available Knowledge has become the most valuable resource of the new era and the resource of the future. The intention of this study is to improve knowledge about the problem of migration of educated people from Serbia from the perspective of scholarship holders who, after being abroad, returned to their country. The aim of this research is to show the profile of the scholarship holders of post-academic and post-graduate students, who studied abroad and then returned to Serbia. Their motives for departure and return, as well as their perception of integration into the work environment in Serbia and utilization of their knowledge is presented. Methods: For the purpose of this research a questionnaire was constructed which was distributed online. Collected data were analysed using statistical tools. Results: This research has shown that the primary motive for education abroad is the desire for personal development. It has also been shown that an important factor for the return of students from abroad is their expectation of comparative advantage in the labour market and their belief of getting a desired job. Apart from this, it is shown that the scholarship holders only partially used the acquired knowledge and thus, do not have enough influence in the development of their organizations.Conclusion: The main research contribution is reflected in the improvement of the knowledge about the motivation of scholars to return from developed countries and highlighted problems which scholarship holders have after returning.Implications and research limitation: the results obtained can be generalised to countries that are passing or have recently moved a transition, and are similar in cultural characteristics. The present contains certain limitations that must be taken into account while interpreting final results. The most significant constraint is the sample size, but the obtained results, especially the motives of the scientific experts for a return to the country

  19. A simple cryo-holder facilitates specimen observation under a conventional scanning electron microscope.

    Science.gov (United States)

    Tang, Chih-Yuan; Huang, Rong-Nan; Kuo-Huang, Ling-Long; Kuo, Tai-Chih; Yang, Ya-Yun; Lin, Ching-Yeh; Jane, Wann-Neng; Chen, Shiang-Jiuun

    2012-02-01

    A pre-cryogenic holder (cryo-holder) facilitating cryo-specimen observation under a conventional scanning electron microscope (SEM) is described. This cryo-holder includes a specimen-holding unit (the stub) and a cryogenic energy-storing unit (a composite of three cylinders assembled with a screw). After cooling, the cryo-holder can continue supplying cryogenic energy to extend the observation time for the specimen in a conventional SEM. Moreover, the cryogenic energy-storing unit could retain appropriate liquid nitrogen that can evaporate to prevent frost deposition on the surface of the specimen. This device is proved feasible for various tissues and cells, and can be applied to the fields of both biology and material science. We have employed this novel cryo-holder for observation of yeast cells, trichome, and epidermal cells in the leaf of Arabidopsis thaliana, compound eyes of insects, red blood cells, filiform papillae on the surface of rat tongue, agar medium, water molecules, penicillium, etc. All results suggested that the newly designed cryo-holder is applicable for cryo-specimen observation under a conventional SEM without cooling system. Most importantly, the design of this cryo-holder is simple and easy to operate and could adapt a conventional SEM to a plain type cryo-SEM affordable for most laboratories. Copyright © 2011 Wiley Periodicals, Inc.

  20. Failure analysis of vise jaw holders for hacksaw machine

    Directory of Open Access Journals (Sweden)

    Essam Ali Al-Bahkali

    2018-01-01

    Full Text Available Failure analysis in mechanical components has been investigated in many studies in the last few years. Failure analysis and prevention are important functions in all engineering disciplines. Materials engineers are often the lead role in the analysis of failures, where a component or product fails in service or if a failure occurs during manufacturing or production processing. In any case, one must determine the cause of the failure to prevent future occurrences and/or to improve the performance of the device, component or structure. For example, the vise jaw holders of hacksaws can break due to accidental heavy loads or machine misuse. The parts that break are the stationary and movable vise jaw holders and the connecter power screw between the holders. To investigate the failure of these components, a three-dimensional finite element model for stress analysis was performed. First, the analysis identified the broken components of the hacksaw machine. In addition, the type of materials of the broken parts was identified, a CAD model was built, and the hacksaw mechanism was analyzed to determine the accurate applied loads on the broken parts. After analyzing the model using Abaqus CAE software, the results showed that the location of the high stresses was identical with the high-stress locations in the original, broken parts. Furthermore, the power screw was subjected to a high load, which deformed the power screw. Also, the stationary vise jaw holder was broken by impact because it was not touched by the power screw until the movable vise jaw holder broke. A conclusion is drawn from the failure analysis and a way to improve the design of the broken parts is suggested.

  1. Research on the tool holder mode in high speed machining

    Science.gov (United States)

    Zhenyu, Zhao; Yongquan, Zhou; Houming, Zhou; Xiaomei, Xu; Haibin, Xiao

    2018-03-01

    High speed machining technology can improve the processing efficiency and precision, but also reduce the processing cost. Therefore, the technology is widely regarded in the industry. With the extensive application of high-speed machining technology, high-speed tool system has higher and higher requirements on the tool chuck. At present, in high speed precision machining, several new kinds of clip heads are as long as there are heat shrinkage tool-holder, high-precision spring chuck, hydraulic tool-holder, and the three-rib deformation chuck. Among them, the heat shrinkage tool-holder has the advantages of high precision, high clamping force, high bending rigidity and dynamic balance, etc., which are widely used. Therefore, it is of great significance to research the new requirements of the machining tool system. In order to adapt to the requirement of high speed machining precision machining technology, this paper expounds the common tool holder technology of high precision machining, and proposes how to select correctly tool clamping system in practice. The characteristics and existing problems are analyzed in the tool clamping system.

  2. Custom sample environments at the ALBA XPEEM

    Energy Technology Data Exchange (ETDEWEB)

    Foerster, Michael, E-mail: mfoerster@cells.es; Prat, Jordi; Massana, Valenti; Gonzalez, Nahikari; Fontsere, Abel; Molas, Bernat; Matilla, Oscar; Pellegrin, Eric; Aballe, Lucia

    2016-12-15

    A variety of custom-built sample holders offer users a wide range of non-standard measurements at the ALBA synchrotron PhotoEmission Electron Microscope (PEEM) experimental station. Some of the salient features are: an ultrahigh vacuum (UHV) suitcase compatible with many offline deposition and characterization systems, built-in electromagnets for uni- or biaxial in-plane (IP) and out-of-plane (OOP) fields, as well as the combination of magnetic fields with electric fields or current injection. Electronics providing a synchronized sinusoidal signal for sample excitation enable time-resolved measurements at the 500 MHz storage ring RF frequency. - Highlights: • Custom sample environment for XPEEM at ALBA. • Sample holders with electromagnets, in-plane dipole, in-plane quadruple and out-of-plane. • Sample holders with printed circuit boards for electric contacts including electromagnets. • UHV suitcase adapter. • Synchronized 500 MHz electrical excitation for time resolved measurements.

  3. Choosing health: qualitative evidence from the experiences of personal health budget holders.

    Science.gov (United States)

    Davidson, Jacqueline; Baxter, Kate; Glendinning, Caroline; Irvine, Annie

    2013-10-01

    Personal health budgets were piloted in the English National Health Service between 2009 and 2012. Semi-structured interviews with a sub-sample of early budget holders aimed to explore their experiences of receiving and using a budget. Over 2000 people from 20 pilot sites were recruited to a multi-method evaluation of the personal health budget pilots. A sub-sample of 58 people was selected for qualitative interviews three months after the offer of a budget; 52 were re-interviewed six months later. The purposively selected sample reflected a range of health conditions, locality, age and gender. Personal health budgets were reported to have positive impacts on health, health care and relatives/family. Benefits often extended beyond the condition for which the budget had been awarded. However, interviewees rarely knew the level of their budget; some reported difficulty in agreeing acceptable uses for their budget; and delays could occur in procuring chosen services or equipment. Patients' experiences offer valuable insights for the roll-out of personal health budgets beyond the pilot phase. Flexibility in how budgets are used may allow maximum benefits to be derived. Clear information about what budgets can and cannot be used for, with suggestions offered, will be useful. People with newly diagnosed or recent sudden onset conditions may need more help to plan their support, but all budget holders are likely to benefit from regular contact with staff for reassurance and continued motivation.

  4. Lathe tool bit and holder for machining fiberglass materials

    Science.gov (United States)

    Winn, L. E. (Inventor)

    1972-01-01

    A lathe tool and holder combination for machining resin impregnated fiberglass cloth laminates is described. The tool holder and tool bit combination is designed to accommodate a conventional carbide-tipped, round shank router bit as the cutting medium, and provides an infinite number of cutting angles in order to produce a true and smooth surface in the fiberglass material workpiece with every pass of the tool bit. The technique utilizes damaged router bits which ordinarily would be discarded.

  5. Structural analysis of 177-FA redesigned surveillance specimen holder tube

    International Nuclear Information System (INIS)

    Pryor, C.W.; Thoren, D.E.; Vames, G.J.; Harris, R.J.

    1976-08-01

    Because of in-service operational problems, the surveillance specimen holder tubes described in B and W topical report BAW-10051 have been redesigned. This report describes the new design and structural analysis for normal operation and upset loading conditions. The results of the analysis demonstrate the adequacy of the new surveillance specimen holder tubes for their design life of 40 years

  6. 7 CFR 1463.105 - Base quota levels for eligible quota holders.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Base quota levels for eligible quota holders. 1463.105 Section 1463.105 Agriculture Regulations of the Department of Agriculture (Continued) COMMODITY... TRANSITION PROGRAM Tobacco Transition Payment Program § 1463.105 Base quota levels for eligible quota holders...

  7. 21 CFR 892.1920 - Radiographic head holder.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A radiographic head holder is a device intended to position the patient's head during a... device is also exempt from the current good manufacturing practice requirements of the quality system...

  8. Equipment for linking source stand and film holder carriage

    International Nuclear Information System (INIS)

    Fajt, P.; Zeman, M.

    1987-01-01

    A device is described for precision link-up of a source stand provided with a spring-loaded cam and a film holder carriage provided with an arm with catches. The catches are mechanically connected to a control device firmly connected to the bottom part of the film holder carriage arm. The cam whose extended part is slidably mounted in the cover guide is secured in position with springs fitted from both sides. The control device consists of an electromagnet with armature connected to the control device pull-rod. The pull-rod provides mechanical connection of the catches and the control device. Upon pressing the pushbutton, the catches automatically engage the film holder cariage arm so that the motorized source stand operates without connection to the carriage. This significantly facilitates the operation of the equipment and reduces physical effort of the technician. The most significant advantage is the possibility of immediate change in operation mode. (J.B.). 5 figs

  9. Brittle Fracture Behaviors of Large Die Holders Used in Hot Die Forging

    Directory of Open Access Journals (Sweden)

    Weifang Zhang

    2017-05-01

    Full Text Available Brittle fracture of large forging equipment usually leads to catastrophic consequences. To avoid this kind of accident, the brittle fracture behaviors of a large die holder were studied by simulating the practical application. The die holder is used on the large die forging press, and it is made of 55NiCrMoV7 hot-work tool steel. Detailed investigations including mechanical properties analysis, metallographic observation, fractography, transmission electron microscope (TEM analysis and selected area electron diffraction (SAED were conducted. The results reveal that the material generated a large quantity of large size polyhedral M23C6 (M: Fe and Cr mainly and elongated M3C (M: Fe mainly carbides along the martensitic lath boundaries when the die holder was recurrently tempered and water-cooled at 250 °C during the service. The large size carbides lead to the material embrittlement and impact toughness degradation, and further resulted in the brittle fracture of the die holder. Therefore, the operation specification must be emphasized to avoid the die holder being cooled by using water, which is aimed at accelerating the cooling.

  10. Implementation of a Light Source in a TEM Sample Holder for In-situ Studies of Photocatalytic Materials

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    can be used inside an environmental TEM (ETEM) allowing specimens to be analyzed during exposure to a controlled gas atmosphere and illumination. The holder is presently being used to study a variety of photoreactive materials and structures, including photocatalysts, photonic devices and solar cells....... For example, electron holography is being used to study p-n junctions both in the presence and in the absence of light in order to assess electron beam induced charging and discharging effects during laser light exposure [3]. Here, we present results from ETEM studies of light-induced phenomena that include...

  11. 14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Holders of type certificates: Fuel tank... Tank Flammability § 26.33 Holders of type certificates: Fuel tank flammability. (a) Applicability. This... part 25 of this chapter. (2) Exception. This paragraph (b) does not apply to— (i) Fuel tanks for which...

  12. Development of a Multimarker Urine Test for Prostate Cancer

    Science.gov (United States)

    2017-10-01

    connected to a chemically etched 20 μm i.d. fused-silica emitter via a Valco stainless steel union. Four μL of individual peptide fractions (total...isomerase family A, member 17 (PD1A17 or member 17); or secreted cement gland protein XAG-2 homolog, AGR2 belongs to the protein disulfide 5 isomerase...silica emitter via a Valco stainless steel union. Four microliters of individual peptide fractions (total volume 20 µL) following PRISM were

  13. 77 FR 69650 - Agency Information Collection Activities: Holders or Containers Which Enter the United States...

    Science.gov (United States)

    2012-11-20

    ... Activities: Holders or Containers Which Enter the United States Duty Free AGENCY: U.S. Customs and Border... information collection requirement concerning the Holders or Containers which Enter the United States Duty... concerning the following information collection: Title: Holders or Containers which Enter the United States...

  14. Development of a magnetic measurement device for thin ribbon samples

    International Nuclear Information System (INIS)

    Sato, Yuta; Todaka, Takashi; Enokizono, Masato

    2008-01-01

    This paper presents a magnetic measurement device for thin ribbon samples, which are produced by rapid cooling technique. This device enables us to measure magnetic properties easily by only inserting a ribbon sample into a sample holder. The sample holder was made by bakelite to fix any width sample. A long solenoid coil was used to generate a uniform magnetic field and the sample holder was placed at the mid part of the solenoid. The magnetic field strength was measured using a shunt resistor and the magnetic flux density and magnetization in sample ribbons were evaluated by using search coils. The accuracy of measurement was verified with an amorphous metal ribbon sample. Next, we have measured magnetic properties of some magnetic shape memory alloys, which have different compositions. The measured results are compared and we clarified the effect of Sm contents on the magnetic properties

  15. Urinary Protein Biomarker Analysis

    Science.gov (United States)

    2017-10-01

    silica emitter via a Valco stainless steel union. Four μL of individual peptide fractions (total volume 20 μL) following PRISM were injected for LC...secreted cement gland protein XAG-2 homolog, AGR2 belongs to the protein disulfide 5 isomerase (PDI) family. The strongest AGR2 expression has...µm C18 column (75 µm i.d. × 10 cm), which was connected to a chemically etched 20 µm i.d. fused-silica emitter via a Valco stainless steel union

  16. [Complaints by private health insurance policy-holders to the Consumer Protection Bureau in Argentina, 2000-2008].

    Science.gov (United States)

    Luzuriaga, María José; Spinelli, Hugo

    2014-05-01

    This paper analyzes problems experienced by policy-holders of voluntary private health insurance plans in Argentina when insurance companies fail to comply with the Consumer Protection Code. The sample consisted of consumer complaints filed with the Consumer Protection Bureau and rulings by the Bureau from 2000 to 2008. One striking issue was recurrent non-compliance with services included in the Mandatory Medical Program and the companies' attempts to blame policy-holders. According to the study, the lack of an information system hinders scientific studies to adequately address the problem. Thus, a comparison with studies on health insurance in other Latin American countries highlighted the importance of such research, the relationship to health systems, constraints on use and denial of citizens' rights to healthcare, and the increasing judicialization of healthcare provision.

  17. FlexED8: the first member of a fast and flexible sample-changer family for macromolecular crystallography.

    Science.gov (United States)

    Papp, Gergely; Felisaz, Franck; Sorez, Clement; Lopez-Marrero, Marcos; Janocha, Robert; Manjasetty, Babu; Gobbo, Alexandre; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Automated sample changers are now standard equipment for modern macromolecular crystallography synchrotron beamlines. Nevertheless, most are only compatible with a single type of sample holder and puck. Recent work aimed at reducing sample-handling efforts and crystal-alignment times at beamlines has resulted in a new generation of compact and precise sample holders for cryocrystallography: miniSPINE and NewPin [see the companion paper by Papp et al. (2017, Acta Cryst., D73, 829-840)]. With full data collection now possible within seconds at most advanced beamlines, and future fourth-generation synchrotron sources promising to extract data in a few tens of milliseconds, the time taken to mount and centre a sample is rate-limiting. In this context, a versatile and fast sample changer, FlexED8, has been developed that is compatible with the highly successful SPINE sample holder and with the miniSPINE and NewPin sample holders. Based on a six-axis industrial robot, FlexED8 is equipped with a tool changer and includes a novel open sample-storage dewar with a built-in ice-filtering system. With seven versatile puck slots, it can hold up to 112 SPINE sample holders in uni-pucks, or 252 miniSPINE or NewPin sample holders, with 36 samples per puck. Additionally, a double gripper, compatible with the SPINE sample holders and uni-pucks, allows a reduction in the sample-exchange time from 40 s, the typical time with a standard single gripper, to less than 5 s. Computer vision-based sample-transfer monitoring, sophisticated error handling and automatic error-recovery procedures ensure high reliability. The FlexED8 sample changer has been successfully tested under real conditions on a beamline.

  18. A large deviation principle in H\\"older norm for multiple fractional integrals

    OpenAIRE

    Sanz-Solé, Marta; Torrecilla-Tarantino, Iván

    2007-01-01

    For a fractional Brownian motion $B^H$ with Hurst parameter $H\\in]{1/4},{1/2}[\\cup]{1/2},1[$, multiple indefinite integrals on a simplex are constructed and the regularity of their sample paths are studied. Then, it is proved that the family of probability laws of the processes obtained by replacing $B^H$ by $\\epsilon^{{1/2}} B^H$ satisfies a large deviation principle in H\\"older norm. The definition of the multiple integrals relies upon a representation of the fractional Brownian motion in t...

  19. 26 CFR 1.860C-1 - Taxation of holders of residual interests.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Taxation of holders of residual interests. 1.860C-1 Section 1.860C-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.860C-1 Taxation of holders...

  20. 16 CFR Figure 3 to Part 1610 - Specimen Holder Supported in Specimen Rack

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Specimen Holder Supported in Specimen Rack 3 Figure 3 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Holder Supported in Specimen Rack ER25MR08.002 ...

  1. Construction and application of a double scanning sample holder; Construction et application d'un porte-echantillon a double balladage

    Energy Technology Data Exchange (ETDEWEB)

    Petit, J; Cabane, G [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    Crystal growth often interferes in the analysis of orientation textures of annealed sheets; in order to achieve the hitting of a great number of grains by the X-ray beam, the sample must be moved in its own plane, the rolling direction remaining parallel to itself. For the study of rolled uranium annealing, one linear scanning was found insufficient; therefore the authors developed a double scanning sample holder allowing the survey of a surface up to 6 or 8 cm{sup 2}. Thus, for recrystallized samples with a grain diameter up to 1 mm, continuous diffraction lines can be obtained. The first diagrams confirm the dilatometric results relating to the texture changes due to {alpha} annealing hard-rolled sheets or to the {alpha}-{beta} allotropic transformation. (author) [French] L'analyse des textures d'orientation des toles apres recuit est souvent genee par le grossissement des cristaux; pour que le faisceau de rayons X frappe toujours un grand nombre de cristaux, on est alors conduit a deplacer l'echantillon dans son plan, la direction de laminage restant parallele a elle eme. Dans l'etude du recuit de l'uranium lamine, un balladage lineaire est insuffisant; c'est pourquoi on a realise un porte chantillon a double balladage permettant l'exploration d'une surface de 6 a 8 cm{sup 2}; on obtient ainsi des anneaux de diffraction continus avec des echantillons recristallises a grains de diametre inferieur ou egal a 1 mm. Les premiers cliches effectues avec cet appareil ont confirme les resultats dilatometriques concernant le changement de texture par recuit en phase {alpha} des toles laminees a fort taux d'ecrouissage, ainsi que le changement de texture au passage de la transformation allotropique {alpha}-{beta}. (auteur)

  2. 19 CFR 134.22 - General rules for marking of containers or holders.

    Science.gov (United States)

    2010-04-01

    ... required for any good of a NAFTA country which is a usual container. (c) Containers or holders bearing a U.S. address. Containers or holders of imported merchandise bearing the name and address of an... shaped or fitted to contain a specific good or set of goods such as a camera case or an eyeglass case, or...

  3. CFD analysis of a scramjet combustor with cavity based flame holders

    Science.gov (United States)

    Kummitha, Obula Reddy; Pandey, Krishna Murari; Gupta, Rajat

    2018-03-01

    Numerical analysis of a scramjet combustor with different cavity flame holders has been carried out using ANSYS 16 - FLUENT tool. In this research article the internal fluid flow behaviour of the scramjet combustor with different cavity based flame holders have been discussed in detail. Two dimensional Reynolds-Averaged Navier-Stokes governing(RANS) equations and shear stress turbulence (SST) k - ω model along with finite rate/eddy dissipation chemistry turbulence have been considered for modelling chemical reacting flows. Due to the advantage of less computational time, global one step reaction mechanism has been used for combustion modelling of hydrogen and air. The performance of the scramjet combustor with two different cavities namely spherical and step cavity has been compared with the standard DLR scramjet. From the comparison of numerical results, it is found that the development of recirculation regions and additional shock waves from the edge of cavity flame holder is increased. And also it is observed that with the cavity flame holder the residence time of air in the scramjet combustor is also increased and achieved stabilized combustion. From this research analysis, it has been found that the mixing and combustion efficiency of scramjet combustor with step cavity design is optimum as compared to other models.

  4. Effect of Holder pasteurization and frozen storage on macronutrients and energy content of breast milk.

    Science.gov (United States)

    García-Lara, Nadia Raquel; Vieco, Diana Escuder; De la Cruz-Bértolo, Javier; Lora-Pablos, David; Velasco, Noelia Ureta; Pallás-Alonso, Carmen Rosa

    2013-09-01

    The aim of this study was to explore the effect of Holder pasteurization and frozen storage at -20°C after pasteurization on fat, total nitrogen, lactose, and energy content of breast milk. Both procedures are routinely practiced in human milk banks. A total of 34 samples of frozen breast milk, donated by 28 women, were collected. Once thawed, an aliquot of each sample was analyzed before pasteurization; the remaining milk was pasteurized (Holder method) and split into 8 aliquots. One aliquot was analyzed after pasteurization and the remainder frozen at -20°C and analyzed 30, 60, 90, 120, and 180 days later. For every aliquot, fat, total nitrogen, lactose, and energy content were determined using the device human Milk Analyzer. We observed a significant reduction in fat (3.5%; -0.17 (-0.29; -0.04) g/dL) and energy content (2.8%; -2.03 (-3.60; -0.46) g/dL) after pasteurization. A significant decrease over time was observed for fat, lactose and energy content. No significant changes were observed for nitrogen content. Mean differences between day 0 postpasteurization and day 180 were -0.13 (-0.21; -0.06) g/dL for fat, -0.08 (-0.13; -0.03) g/dL for lactose, and -1.55 (-2.38; -0.71) kcal/dL for energy content. The relative decreases were 2.8%, 1.7%, and 2.2%, respectively. Overall (postpasteurization + frozen storage), a 6.2% and 5% decrease were observed for fat and energy, respectively. Holder pasteurization decreased fat and energy content of human milk. Frozen storage at -20°C of pasteurized milk significantly reduced fat, lactose, and energy content of human milk.

  5. Punishability of office-holders in environmental law

    International Nuclear Information System (INIS)

    Papier, H.J.

    1988-01-01

    The author deals with the question of criminal responsibility of office-holders in the field of environmental law. The provisions in secs. 324-330 of the Penal Code do not grant independent or origin protection from violation of the law. They depend on administrative law regulations. (WG) [de

  6. Highly identified power-holders feel responsible: The interplay between social identification and social power within groups.

    Science.gov (United States)

    Scholl, Annika; Sassenberg, Kai; Ellemers, Naomi; Scheepers, Daan; de Wit, Frank

    2018-01-01

    Power relations affect dynamics within groups. Power-holders' decisions not only determine their personal outcomes, but also the outcomes of others in the group that they control. Yet, power-holders often tend to overlook this responsibility to take care of collective interests. The present research investigated how social identification - with the group to which both the powerful and the powerless belong - alters perceived responsibility among power-holders (and the powerless). Combining research on social power and social identity, we argue that power-holders perceive more responsibility than the powerless when strongly (rather than when weakly) identifying with the group. A study among leaders and an experiment supported this, highlighting that although power-holders are often primarily concerned about personal outcomes, they do feel responsible for considering others' interests when these others are included in the (social) self. © 2017 The British Psychological Society.

  7. Darfur and the flaws of Holder v HLP

    Directory of Open Access Journals (Sweden)

    Christopher Thornton

    2011-03-01

    Full Text Available When US Chief Justice Roberts handed down the judgment in Holder v Humanitarian Law Project, he revealed the Supreme Court’s tragic under-estimation of the potential of engagement with non-state armed groups....

  8. Effect of Holder pasteurization on macronutrients and immunoglobulin profile of pooled donor human milk.

    Science.gov (United States)

    Adhisivam, B; Vishnu Bhat, B; Rao, Krishna; Kingsley, S M; Plakkal, Nishad; Palanivel, C

    2018-03-27

    The objective of this study was to study the effect of Holder pasteurization on macronutrients and immunoglobulin profile of pooled donor human milk. This descriptive study was conducted in a Human Milk Bank of a tertiary care teaching institute in south India. Thirty random paired pooled donor human milk samples (before and after pasteurization) were analyzed for macronutrients (protein, fat, carbohydrates) using infrared spectroscopy. Similarly, immunoglobulin profile (IgA and IgG) before and after pasteurization was quantified using ELISA. The mean values of protein, fat, and carbohydrates in pooled donor milk pre-pasteurization were 1.6, 3.6, and 6.1 g/dl compared with post-pasteurization values 1.4, 2.7, and 5.9 g/dl, respectively. Pasteurization reduced protein, fat, and energy content of pooled donor milk by 12.5%, 25%, and 16%, respectively. However, carbohydrates were not significantly reduced. Pasteurization decreased IgA by 30% and IgG by 60%. Holder pasteurization of pooled donor human milk decreases protein, fat, and energy content and also reduces the levels of IgA and IgG.

  9. STATISTICAL ASSESSMENT OF CAREERS OF DOCTORATE HOLDERS SURVEY BY CORRESPONDENCE ANALYSIS: THE CASE OF TURKEY

    OpenAIRE

    Zerrin AŞAN GREENACRE

    2018-01-01

    Nowadays, doctorate holders are not only academician and researcher, also they play roles across a wide range of working areas within society. These areas are increasing multiway. The aim of this study is to give statistical evaluation careers of doctorate holders survey using  the correspondence analysis with supplementary variables. In this paper  we focused on careers of doctorate holders  in Turkey. It was held a survey by  Turkish   Statistical Institute on this s...

  10. 14 CFR Appendix O to Part 121 - Hazardous Materials Training Requirements For Certificate Holders

    Science.gov (United States)

    2010-01-01

    ... K of this chapter. The training requirements for various categories of persons are defined by job... to persons actually performing the job function. Training requirements for certificate holders.... The method of delivering the training will be determined by the certificate holder. The certificate...

  11. 7 CFR 762.144 - Repurchase of guaranteed portion from a secondary market holder.

    Science.gov (United States)

    2010-01-01

    ... discrepancy is resolved. (iii) In the case of a request for Agency purchase, the Agency will only pay interest... and the amount due the holder. (ii) Any discrepancy between the amount claimed by the holder and the... approved by the Agency. The Agency will not participate in resolution of any such discrepancy. When there...

  12. Thermal Stress FE Analysis of Large-scale Gas Holder Under Sunshine Temperature Field

    Science.gov (United States)

    Li, Jingyu; Yang, Ranxia; Wang, Hehui

    2018-03-01

    The temperature field and thermal stress of Man type gas holder is simulated by using the theory of sunshine temperature field based on ASHRAE clear-sky model and the finite element method. The distribution of surface temperature and thermal stress of gas holder under the given sunshine condition is obtained. The results show that the thermal stress caused by sunshine can be identified as one of the important factors for the failure of local cracked oil leakage which happens on the sunny side before on the shady side. Therefore, it is of great importance to consider the sunshine thermal load in the stress analysis, design and operation of large-scale steel structures such as the gas holder.

  13. Mechanical Conversion for High-Throughput TEM Sample Preparation

    International Nuclear Information System (INIS)

    Kendrick, Anthony B; Moore, Thomas M; Zaykova-Feldman, Lyudmila

    2006-01-01

    This paper presents a novel method of direct mechanical conversion from lift-out sample to TEM sample holder. The lift-out sample is prepared in the FIB using the in-situ liftout Total Release TM method. The mechanical conversion is conducted using a mechanical press and one of a variety of TEM coupons, including coupons for both top-side and back-side thinning. The press joins a probe tip point with attached TEM sample to the sample coupon and separates the complete assembly as a 3mm diameter TEM grid, compatible with commercially available TEM sample holder rods. This mechanical conversion process lends itself well to the high through-put requirements of in-line process control and to materials characterization labs where instrument utilization and sample security are critically important

  14. Position of document holder and work related risk factors for neck pain among computer users: a narrative review.

    Science.gov (United States)

    Ambusam, S; Baharudin, O; Roslizawati, N; Leonard, J

    2015-01-01

    Document holder is used as a remedy to address occupational neck pain among computer users. An understanding on the effects of the document holder along with other work related risk factors while working in computer workstation requires attention. A comprehensive knowledge on the optimal location of the document holder in computer use and associated work related factors that may contribute to neck pain reviewed in this article. A literature search has been conducted over the past 14 years based on the published articles from January 1990 to January 2014 in both Science Direct and PubMed databases. Medical Subject Headings (MeSH) keywords for search were neck muscle OR head posture OR muscle tension' OR muscle activity OR work related disorders OR neck pain AND/OR document location OR document holder OR source document OR copy screen holder.Document holder placed lateral to the screen was most preferred to reduce neck discomfort among occupational typists. Document without a holder was placed flat on the surface is least preferred. The head posture and muscle activity increases when the document is placed flat on the surface compared to when placed on the document holder. Work related factors such as static posture, repetitive movement, prolong sitting and awkward positions were the risk factors for chronic neck pain. This review highlights the optimal location for document holder for computer users to reduce neck pain. Together, the importance of work related risk factors for to neck pain on occupational typist is emphasized for the clinical management.

  15. Sampling inspection device

    International Nuclear Information System (INIS)

    Chiba, Keiichi.

    1996-01-01

    A holder is inserted to a holder guide, and is stopped at a position where one end of a hook disposed to the holder is not in contact with the holder guide (a position where hooks do not work). A cap incorporated with wiping paper is pushed up into a holder by a device rod with the wiping paper situated downwardly. The hooks of the holder are engaged to the grooves of the cap to secure the cap. The holder is moved to a predetermined place to wipe off the deposited materials on the surface of a vessel which contains radioactive wastes. Then, the holder is inserted to the holder guide, and is stopped at a position where the one end of the holder is raised. The securement of the gap is released, the cap is forced into a recovering cover by a discharging rod. The hooks of the recovering cover are caught by the grooves of the cap to secure the cap. Then, the cap is transported to a radioactivity measuring chamber. (I.N.)

  16. Gender differentials in market participation among small-holder ...

    African Journals Online (AJOL)

    Gender differentials in market participation among small-holder cassava farmers ... The results showed that the female farmers participated and sold more cassava in the market than their male counterparts. ... facilitate faster delivery of farm produce especially perishable commodities such as ... AJOL African Journals Online.

  17. Investigation of a flame holder geometry effect on flame structure in non-premixed combustion

    International Nuclear Information System (INIS)

    Hashemi, S. A.; Hajialigol, N.; Fattahi, A.; Heydari, R.; Mazaheri, K.

    2013-01-01

    In this paper the effect of flame holder geometry on flame structure is studied. The obtained numerical results using realizable k-ε and β-PDF models show a good agreement with experimental data. The results show that increasing in flame holder length decreases flame length and increases flame temperature. Additionally, it is observed that flame lengths decrease by increasing in flame holder radius and increase for larger radii. Furthermore in various radii, the flame temperature is higher for smaller flame lengths. It was found that behavior of flame structure is mainly affected by the mass flow rate of hot gases that come near the reactant by the recirculation zone.

  18. Investigation of a flame holder geometry effect on flame structure in non-premixed combustion

    Energy Technology Data Exchange (ETDEWEB)

    Hashemi, S. A.; Hajialigol, N.; Fattahi, A.; Heydari, R. [University of Kashan, Kashan (Iran, Islamic Republic of); Mazaheri, K. [University of Tarbiat Moddares, Tehran (Iran, Islamic Republic of)

    2013-11-15

    In this paper the effect of flame holder geometry on flame structure is studied. The obtained numerical results using realizable k-ε and β-PDF models show a good agreement with experimental data. The results show that increasing in flame holder length decreases flame length and increases flame temperature. Additionally, it is observed that flame lengths decrease by increasing in flame holder radius and increase for larger radii. Furthermore in various radii, the flame temperature is higher for smaller flame lengths. It was found that behavior of flame structure is mainly affected by the mass flow rate of hot gases that come near the reactant by the recirculation zone.

  19. Test sample handling apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    A test sample handling apparatus using automatic scintillation counting for gamma detection, for use in such fields as radioimmunoassay, is described. The apparatus automatically and continuously counts large numbers of samples rapidly and efficiently by the simultaneous counting of two samples. By means of sequential ordering of non-sequential counting data, it is possible to obtain precisely ordered data while utilizing sample carrier holders having a minimum length. (U.K.)

  20. The Effect of Holder Pasteurization on Activin A Levels in Human Milk.

    Science.gov (United States)

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Li Volti, Giovanni; Galvano, Fabio; Barbagallo, Ignazio; Visser, Gerard H A; Gazzolo, Diego

    2016-11-01

    There is evidence that mother's own milk is the best nutrient in terms of multiorgan protection and infection prevention. However, when maternal milk is scarce, the solution can be represented by donor milk (DM), which requires specific storage procedures such as Holder Pasteurization (HoP). HoP is not free from side effects since it is widely known that it causes qualitative/quantitative changes in milk composition, particularly in the protein content. Therefore, the aim of this study is to investigate the effects of HoP on Activin A, a neurobiomarker known to play an important role in the development and protection of the central nervous system. In 24 mothers who delivered preterm (n = 12) and term (n = 12) healthy newborns, we conducted a pretest/test study where the milk donors acted as their own controls. Each sample was divided into two parts: the first was frozen at -80°C (Group 1); the second was Holder-pasteurized before freezing at -80°C (Group 2). Activin A was quantified using an ELISA test. Activin A was detected in all samples. There were no significant differences (p > 0.05) between the two groups, also when the analysis was stratified for gestational age at delivery and milk maturation degree (p > 0.05, for both). The present findings on the absence of any side effects of HoP on the milk concentration of Activin A offer additional support to the efficacy of HoP in DM storage. Our data open up to further investigations on neurobiomarkers' assessment in human milk and their preanalytical stability according to storage procedures.

  1. Research Amplitudo Vibration On Holder Due To The Process Of Lathe Nozzle Rocket RX 450

    Science.gov (United States)

    Ediwan; Budi Djatmiko, Agus; Dody Arisandi, EfFendy; Purnomo, Heri; Ibadi, Mahfud

    2018-04-01

    The main function of the rocket nozzle is to convert the enthalpy efficiency from combustion gas to kinetic energy and also to make high velocity out of the gas. The rocket nozzle usually consists of a converging and diverging part. With a smaller area on the neck and enlarged at the exit area. The velocity flow through the nozzle enlarges into the speed of sound through the neck and then becomes super sonic in the divergent part. Nozzle making or machining using conventional lathes, first performed is drilling on a massive metal that is bonded to the veneer, then after a sufficient gap is done deep-boring. At the time of the process of lathe in the nozzle RX 450 there is an obstacle that is vibrating tool holder chisel or holder so it is worried about not precision of the process of lathe. This should not happen because it can cause failure in the latter for it needs to be studied and studied further so that the lathe process goes accordingly. The holder material of ST 60 with a modulus of elasticity 200 GPa and a nozzle material of AISI 4340 alloy steel with σyield = 470 MPa, Shear Modulus G = 80 GPa. The purpose of this research is to observe the amplitude of vibration on the holder due to RX- 450 nozzle lathe processing for the purpose of amplitude that occurs in accordance with the desired so that the nozzle structure is no damage process. The result of the research was obtained holder with length (L) 80cm, profile width (B) 5 cm, height of profile (H) 10 cm, turning machine ω = 8.98 rad / sec and natural holder frequency ωn = 89.8 rad / second, Amplitude of vibration of δ = 1.21 mm, while the amplitude of the design X = 1.22 mm From the results of this study it can be said that the holder of a chisel or holder can be used as a tool at the time of RX nozzle retrieval process and is quite safe because it works under the condition ω/ω n Rocket Payload "AKPV Engineering University of Wyoming 2009 )

  2. A MEMS-based heating holder for the direct imaging of simultaneous in-situ heating and biasing experiments in scanning/transmission electron microscopes.

    Science.gov (United States)

    Mele, Luigi; Konings, Stan; Dona, Pleun; Evertz, Francis; Mitterbauer, Christoph; Faber, Pybe; Schampers, Ruud; Jinschek, Joerg R

    2016-04-01

    The introduction of scanning/transmission electron microscopes (S/TEM) with sub-Angstrom resolution as well as fast and sensitive detection solutions support direct observation of dynamic phenomena in-situ at the atomic scale. Thereby, in-situ specimen holders play a crucial role: accurate control of the applied in-situ stimulus on the nanostructure combined with the overall system stability to assure atomic resolution are paramount for a successful in-situ S/TEM experiment. For those reasons, MEMS-based TEM sample holders are becoming one of the preferred choices, also enabling a high precision in measurements of the in-situ parameter for more reproducible data. A newly developed MEMS-based microheater is presented in combination with the new NanoEx™-i/v TEM sample holder. The concept is built on a four-point probe temperature measurement approach allowing active, accurate local temperature control as well as calorimetry. In this paper, it is shown that it provides high temperature stability up to 1,300°C with a peak temperature of 1,500°C (also working accurately in gaseous environments), high temperature measurement accuracy (in-situ S/TEM imaging experiments, but also elemental mapping at elevated temperatures using energy-dispersive X-ray spectroscopy (EDS). Moreover, it has the unique capability to enable simultaneous heating and biasing experiments. © 2016 Wiley Periodicals, Inc.

  3. 78 FR 9720 - Agency Information Collection Activities: Holders or Containers Which Enter the United States...

    Science.gov (United States)

    2013-02-11

    ... Activities: Holders or Containers Which Enter the United States Duty Free AGENCY: U.S. Customs and Border... or Containers which enter the United States Duty Free. This is a proposed extension of an information..., or other technological techniques or other forms of information. Title: Holders or Containers which...

  4. 32 CFR 767.9 - Content of permit holder's final report.

    Science.gov (United States)

    2010-07-01

    ... RULES APPLICATION GUIDELINES FOR ARCHEOLOGICAL RESEARCH PERMITS ON SHIP AND AIRCRAFT WRECKS UNDER THE.... The permit holder's final report shall include the following: (a) A site history and a contextual...

  5. Socio-economic characteristics of small-holder farmers influencing ...

    African Journals Online (AJOL)

    Socio-economic characteristics of small-holder farmers influencing their utilisation of microcredit in the central agricultural zone of Cross River state. ... The findings revealed that about thirty – four percent (33.6%) of the crop farmers fell between 41-50 years while about 51% of the livestock farmers fell between 31-40 years.

  6. A new holder and surface MRI coil for the examination of the newborn infant hip

    Energy Technology Data Exchange (ETDEWEB)

    Krasny, R. (Dept. of Diagnostic Radiology, Univ. of Technology, Aachen (Germany)); Casser, H.R. (Dept. of Orthopedics, Univ. of Technology, Aachen (Germany)); Requardt, H. (Siemens AG, Erlangen (Germany)); Botschek, A. (Dept. of Diagnostic Radiology, Univ. of Technology, Aachen (Germany))

    1993-11-01

    A special holder was developed for examination of the infant hip joint using MRI. This holder allows the infant hip joint to be examined both in a neutral position and in various defined functional positions. A special integrated surface coil, also developed for this purpose, provides the high spatial resolution required for assessment of the fine joint structures. Thirty infants were examined and the new device has proved useful in advanced hip dysplasia, therapy-resistant subluxation and luxation, and for operative therapy planning (reconstruction of the acetabular roof, redirectional osteotomies). Interpretation errors due to misprojection can be eliminated to a large extent since the holder allows standardized and reproducible positioning. (orig.)

  7. Warm Deep Drawing of Rectangular Parts of AZ31 Magnesium Alloy Sheet Adopting Variable Blank Holder Force

    International Nuclear Information System (INIS)

    Peng Yinghong; Chang Qunfeng; Li Dayong; Zeng Xiaoqin

    2007-01-01

    AZ31 magnesium alloy sheet with good shape and formability is fabricated by warm cross rolling. Uniaxial tensile tests are conducted using a Gleeble 3500 thermal - mechanical simulator, and the mechanical properties of AZ31 magnesium alloy sheet are analyzed. A warm deep drawing process of square part is also simulated by the finite element method. The influences of blank holder force on the formability are numerically investigated. A double-action hydraulic press that can realize adjustable blank holder forces is developed and its working principle and control system are introduced. Some warm deep drawing experiments of square parts of AZ31 magnesium alloy sheet are also performed. Different variation schemes of the blank holder force with the stroke of the punch are tested, and the experiment results are compared. Results show that the suitable blank holder force variation scheme is a ladder curve with the punch stroke. Adopting the variable blank holder force technique can improve 13.2% of the drawing depth of square parts of AZ31 magnesium alloy sheet

  8. Glove holder system for containment shell

    International Nuclear Information System (INIS)

    Picco, B.

    1993-01-01

    A glove holder for an isolated chamber used e.g. for handling toxic or radioactive materials and made with at least one access port in its wall, equipped with a ring to which the glove is attached, has a sleeve which connects the ring to the glove proper and protects the forarm. The sleeve is in at least two sections, a first corrugated section and a second, supple section which is able to fold inside the first section. ADVANTAGE - Reduced costs and quantity of waste produced by enabling glove proper only to be replaced. (author)

  9. Small holder farmers coping strategies to household food insecurity ...

    African Journals Online (AJOL)

    This study has aimed at examining the small holder farmers' coping strategies to sustained household food insecurity and hunger in Southern Ethiopia (Sidama Zone). In order to collect the required input data, a comprehensive interview schedule was developed. The data were collected from 614 households who were ...

  10. Small holder farmers coping strategies to household food insecurity ...

    African Journals Online (AJOL)

    Small holder farmers coping strategies to household food insecurity and hunger in Southern Ethiopia. ... Ethiopian Journal of Environmental Studies and Management ... The study further showed that households in the study area employ a range of coping strategies to respond to the high and sustained food insecurity and ...

  11. Material selection for the tool holder working under hard milling conditions using different multi criteria decision making methods

    International Nuclear Information System (INIS)

    Çalışkan, Halil; Kurşuncu, Bilal; Kurbanoğlu, Cahit; Güven, Şevki Yılmaz

    2013-01-01

    Highlights: ► The material selection problem for tool holders used in hard milling was solved. ► EXPROM2, TOPSIS and VIKOR methods were used for ranking the alternative materials. ► The weighting of criteria was performed by compromised weighting method. ► The best material for the tool holder was selected as Fe–5Cr–Mo–V aircraft steel. -- Abstract: Nowadays machining of materials in their hardened state, also called hard machining, is a challenge in production of tools and molds. It has some advantages such as lower process time and lower manufacturing cost when compared to conventional machining. In machining of hard workpiece materials, however, very high stresses act on the tool holder through the cutting tool. These stresses necessitate the tool holder to have some specific properties. Especially in hard milling, the tool holder should have high stiffness and should be able to dissipate the energy generated during interrupted cutting. Material cost of the tool holder is also important since lower costs provide a competitive advantage for manufacturers. The material selection for the tool holder should be conducted considering aforementioned requirements. To tackle the difficulty of the material selection with specific properties from a large number of alternatives, multi-criteria decision-making (MCDM) methods have been used. In this paper a decision model including extended PROMETHEE II (EXPROM2) (preference ranking organization method for enrichment evaluation), TOPSIS (technique for order performance by similarity to ideal solution) and VIKOR (VIšekriterijumsko KOmpromisno Rangiranje) methods were used for the selection of the best material for the tool holder used in hard milling. The criteria weighting was performed by compromised weighting method composed of AHP (analytic hierarchy process) and Entropy methods. The candidate materials were ranked by using these methods and the results obtained by each method were compared. It was confirmed

  12. Integrating sphere based reflectance measurements for small-area semiconductor samples

    Science.gov (United States)

    Saylan, S.; Howells, C. T.; Dahlem, M. S.

    2018-05-01

    This article describes a method that enables reflectance spectroscopy of small semiconductor samples using an integrating sphere, without the use of additional optical elements. We employed an inexpensive sample holder to measure the reflectance of different samples through 2-, 3-, and 4.5-mm-diameter apertures and applied a mathematical formulation to remove the bias from the measured spectra caused by illumination of the holder. Using the proposed method, the reflectance of samples fabricated using expensive or rare materials and/or low-throughput processes can be measured. It can also be incorporated to infer the internal quantum efficiency of small-area, research-level solar cells. Moreover, small samples that reflect light at large angles and develop scattering may also be measured reliably, by virtue of an integrating sphere insensitive to directionalities.

  13. 17 CFR 240.14a-7 - Obligations of registrants to provide a list of, or mail soliciting material to, security holders.

    Science.gov (United States)

    2010-04-01

    ..., form of proxy or other communication to such holders, including to the extent known or reasonably... provided for under applicable state law identifying the proposal or other corporate action that will be the subject of the security holder's solicitation or communication and attesting that: (i) The security holder...

  14. Report on the Installation and Preparedness of a Protochips Fusion in-situ Heating Holder for TEM

    Energy Technology Data Exchange (ETDEWEB)

    Edmondson, Philip D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    This brief report documents the procurement and installation of a Protochips Fusion (formerly Aduro) high-temperature, high stability transmission electron microscopy (TEM) specimen holder that allows for the high spatial resolution characterization of material specimens at high temperature in situ of an electron microscope. This specimen holder was specifically procured for use with The FEI Talos F200X Scanning/Transmission Electron Microscope (STEM) in Oak Ridge National Laboratory’s (ORNL’s) Low Activation Materials Development and Analysis (LAMDA) Laboratory. The Protochips Fusion holder will enable high-resolution structural and chemical analysis of irradiated materials at high temperature, becoming a unique capability worldwide, and would encourage high-quality in situ experiments to be conducted on irradiated materials.

  15. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    Science.gov (United States)

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Proposal of a Budget-Friendly Camera Holder for Endoscopic Ear Surgery.

    Science.gov (United States)

    Ozturan, Orhan; Yenigun, Alper; Aksoy, Fadlullah; Ertas, Burak

    2018-01-01

    Endoscopic ear surgery (EES) is increasingly a preferred technique in otologic society. It offers excellent visualization of the anatomical structures directly and behind the corners with variable angled telescopes. It also provides reduced operative morbidity due to being able to perform surgical interventions with less invasive approaches. Operative preparation and setup time and cost of endoscopy system are less expensive compared with surgical microscopes. On the other hand, the main disadvantage of EES is that the surgery has to be performed with 1 single hand. It is certainly restrictive for an ear surgeon who has been operating with 2 hands under otologic microscopic views for years and certainly requires a learning period and perseverance. Holding the endoscope by a second surgeon is not executable because of insufficient surgical space.Endoscope/camera holders have been developed for those who need the comfort and convenience afforded by double-handed microscopic ear surgery. An ideal endoscope holder should be easy-to-set up, easily controlled, providing a variety of angled views, allowing the surgeon to operate with 2 hands and, budget-friendly. In this article, a commercially available 11-inch magic arm camera holder is proposed by the authors to be used in EES due to its versatile, convenient, and budget-friendly features. It allows 2-handed EES through existing technology and is affordable for surgeons looking for a low-cost and practical solution.

  17. Repositioning accuracy: Comparison of a noninvasive head holder with thermoplastic mask for fractionated radiotherapy and a case report

    International Nuclear Information System (INIS)

    Sweeney, Reinhart; Bale, Reto; Vogele, Michael; Nevinny-Stickel, Meinhart; Bluhm, Anja; Auer, Thomas; Hessenberger, Gerhart; Lukas, Peter

    1998-01-01

    Purpose: To compare accuracy, clinical feasibility, and subjective patient impression between a noninvasive head holder (Vogele Bale Hohner [VBH]; Wellhoefer Dosimetry, Schwarzenbruck, Germany) developed at the University of Innsbruck and the thermoplastic mask fixation system for use in fractionated external radiotherapy. We present a case report of an actual patient fixated in the VBH head holder during radiation therapy. Materials and Methods: The VBH head holder consists of an individualized vacuum dental cast connected to a head plate via two hydraulic arms allowing noninvasive, reproducible head fixation of even uncooperative patients. Accuracy was tested and compared with that of the thermoplastic mask using the Phillips EasyGuide navigation system on five volunteers. Specific external registration points served as landmarks and their positions were compared after each repositioning. System and operator inaccuracy were also taken into account. The times taken for production and repositioning of the respective fixation devices were compared, and subjective impressions were noted. Results: Mean VBH head holder repositioning accuracy was 1.02 mm while that of the thermoplastic mask was 3.05 mm. 69% of mask repositionings showed a deviation > 2 mm and 41% > 3 mm (as opposed to 8% and 1% respectively for the VBH head holder) Those points located farthest away from the respective plane of fixation showed the largest deviations. Both production and repositioning times were similar between the systems; depending upon the patient, the VBH head holder was generally better tolerated than the mask system. Conclusion: Due to its significantly better repositioning accuracy compared to that of the thermoplastic mask, the VBH head holder is especially suited for external radiation requiring precise repositioning due to critical tissues in immediate surrounding of the area to be irradiated

  18. Device for radioactivity measurement of liquid samples

    International Nuclear Information System (INIS)

    Lamaziere, J.

    1983-01-01

    The device for low activity gamma measurements comprises an automatic changer for sample transfer from a conveyor to a measuring chamber. The conveyor includes a horizontal table were are regularly distributed sample holders. A lift allows a vertical motion of a plate for the exposition in front of a detector [fr

  19. Multielement analysis of aerosol samples by X-ray fluorescence analysis with totally reflecting sample holders

    International Nuclear Information System (INIS)

    Ketelsen, P.; Knoechel, A.

    1984-01-01

    Aerosole samples on filter support were analyzed using the X-ray flourescence analytical method (Mo excitation) with totally reflecting sample carrier (TXFA). Wet decomposition of the sample material with HNO 3 in an enclosed system and subsequent sample preparation by evaporating an aliquot of the solution on the sample carrier yields detection limits up to 0.3 ng/cm 2 . The reproducibilities of the measurements of the elements K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb lie between 5 and 25%. Similar detection limits and reproducibilities are obtained, when low-temperature oxygen plasma is employed for the direct ashing of the homogenously covered filter on the sample carrier. For the systematic loss of elements both methods were investigated with radiotracers as well as with inactive techniques. A comparison of the results with those obtained by NAA, AAS and PIXE shows good agreement in most cases. For the bromine determination and the fast coverage of the main elements a possibility for measuring the filter membrane has been indicated, which neglects the ashing step. The corresponding detection limits are up to 3 ng/cm 2 . (orig.) [de

  20. Liquid scintillation systems and apparatus for measuring high-energy radiation emitted by samples in standard laboratory test tubes

    International Nuclear Information System (INIS)

    Benvenutti, R.A.

    1976-01-01

    Liquid scintillation detection system employs improved sample holders in which the cap of a glass vial is provided with a well for receiving a standard laboratory test tube containing a radioactive sample. The well is immersed in a liquid scintillator in the vial, the scintillator containing lead acetate solution to enhance its efficiency. A commercially available beta-counting liquid scintillation apparatus is modified to provide gamma-counting with the improved sample holders

  1. Sieve-based device for MALDI sample preparation. I. Influence of sample deposition conditions in oligonucleotide analysis to achieve significant increases in both sensitivity and resolution.

    Science.gov (United States)

    Molin, Laura; Cristoni, Simone; Crotti, Sara; Bernardi, Luigi Rossi; Seraglia, Roberta; Traldi, Pietro

    2008-11-01

    Spraying of oligonucleotide-matrix solutions through a stainless steel (ss) sieve (38 microm, 450 mesh) leads to the formation, on the matrix-assisted laser desorption/ionization (MALDI) sample holder, of uniformly distributed microcrystals, well separated from each other. When the resulting sample holder surface is irradiated by laser, abundant molecular species form, with a clear increase in both intensity and resolution with respect to values obtained by 'Dried Droplet', 'Double Layer', and 'Sandwich' deposition methods. In addition, unlike the usual situation, the sample is perfectly homogeneous, and identical spectra are obtained by irradiating different areas. On one hand, the data indicate that this method is highly effective for oligonucleotide MALDI analysis, and on the other, that it can be validly employed for fully automated MALDI procedures.

  2. Modeling returns to education and labour market outcomes of doctoral degree holders in Bulgaria

    OpenAIRE

    Simeonova-Ganeva, Ralitsa; Panayotova, Nataliya; Ganev, Kaloyan

    2013-01-01

    In this study we present the theoretical framework of the so called Mincerian equations used for modelling returns to education. Then, we construct a conceptual framework which allows us to answer the question “What happens to doctoral degree holders in the labour market?”. We analyse data for about 45,000 PhD graduates in Bulgaria from the NSI survey Career development of PhD degree holders run in 2007, 2009, and 2010. An attempt is made to measure pay gaps in terms of gender and major of st...

  3. Micro-PIXE on thin plant tissue samples in frozen hydrated state: A novel addition to JSI nuclear microprobe

    International Nuclear Information System (INIS)

    Vavpetič, P.; Pelicon, P.; Vogel-Mikuš, K.; Grlj, N.; Pongrac, P.; Jeromel, L.; Ogrinc, N.; Regvar, M.

    2013-01-01

    Recently we completed a construction of a cryostat at Jožef Stefan Institute (JSI) nuclear microprobe enabling us to analyze various types of biological samples in frozen hydrated state using micro-PIXE/STIM/RBS. Sample load-lock system was added to our existing setup to enable us to quickly insert a sample holder with frozen hydrated tissue samples onto a cold goniometer head cooled with liquid nitrogen inside the measuring chamber. Cryotome-cut slices of frozen hydrated plant samples were mounted between two thin silicon nitride foils and then attached to the sample holder. Sufficient thermal contact between silicon nitride foils and sample holder must be achieved, as well as between the sample holder and the cold goniometer head inside the measuring chamber to prevent melting of the samples. Matrix composition of frozen hydrated tissue is consisted mostly of ice. Thinning of the sample as well as water evaporation during high vacuum and proton beam exposure was inspected by the measurements with RBS and STIM method simultaneously with micro-PIXE. For first measuring attempts a standard micro-PIXE configuration for tissue mapping was used with proton beam cross section of 1.2 × 1.2 μm 2 and a beam current of 100 pA. The temperature of the cold goniometer head was kept below 130 K throughout the entire proton beam exposure. First measurements of thin plant tissue samples in frozen hydrated state show minute sample degradation during the 10 h period of micro-PIXE measurements

  4. Compact design of a transmission electron microscope-scanning tunneling microscope holder with three-dimensional coarse motion

    International Nuclear Information System (INIS)

    Svensson, K.; Jompol, Y.; Olin, H.; Olsson, E.

    2003-01-01

    A scanning tunneling microscope (STM) with a compact, three-dimensional, inertial slider design is presented. Inertial sliding of the STM tip, in three dimensions, enables coarse motion and scanning using only one piezoelectric tube. Using the same electronics both for scanning and inertial sliding, step lengths of less than 5% of the piezo range were achieved. The compact design, less than 1 cm3 in volume, ensures a low mechanical noise level and enables us to fit the STM into the sample holder of a transmission electron microscope (TEM), while maintaining atomic scale resolution in both STM and TEM imaging

  5. A Study on consensus development through stake holder engagement for the use of nuclear energy in Japan

    International Nuclear Information System (INIS)

    Aoyama, Yoshiko; Sawada, Tetsuo; Fujii, Yasuhiko

    2008-01-01

    In order to alleviate the distrust surrounding the use of nuclear energy and operation of nuclear facilities, as well as to foster trust and find better ways to live in harmony with society, it is essential for the state and electric power utilities not to provide one-sided information, but to formulate adequate bilateral communication and dialogue with stake holders. In this study, we conducted a case study focused on four stake holder meetings with a view to ensuring safety in the use of nuclear energy and operation of nuclear facilities in Japan; the 'Community Meeting for Securing the Transparency of Kashiwazaki-Kariwa Nuclear Power Station (Chiiki-no-kai)'; the 'Monitoring and Evaluation Conference on Environmental Radiation', established by communities where nuclear facilities are installed; the 'Round-Table Conference on Nuclear Power Policy' and the 'Conference for Public Participation and Decision Making for Nuclear Energy Policy' organized by Japan Atomic Energy Commission. As a consequence, it has been observed that in each case varying opinions were summarized through stake holder meetings, but the fact that no system exists to reflect these opinions in design of the nuclear energy policy has emerged as a controversial point. This study suggests future efforts in regard to the requirements in Japan for stake holder meetings that are necessary for fostering trust and mutual understanding among stake holders including the state and local government, electric power utilities and local residents. (author)

  6. 15N tracer technique for studying efficiency of deep placed fertilizer through nutriseed holder in direct seeded rice

    International Nuclear Information System (INIS)

    Asha, V.S.; Arulmozhiselvan, K.

    2006-01-01

    In order to estimate N use efficiency in deep placement of NPK straight fertilizers, two pot experiments were conducted in high clay soil with direct seeded rice. 15 N urea was used as a tracer. A newly designed 'Nutriseed Holder' was used for simultaneous deep placement of fertilizers and sowing of seeds. Each holder had two cavities, one on top for holding seed and another one at bottom for holding fertilizer material. By implanting a holder in puddled soil, a rice hill was established. The length (5 or 10 cm) and width (8 or 12 mm) of nutriseed holder was standardized while evaluating the effect of Azolla, neem and seed inoculants. Appreciably, deep placement of plain NPK fertilizer in 12 mm holder placed at 5 cm depth recorded the highest grain yield with a yield increase of 81.8 per cent during rabi 2002 (cv CO 43) and 84.8 per cent during summer 2003 (cv CO 47) over broadcast application. Further, it increased recovery of added JSN in grain + straw to the tune of 57.1 per cent in rabi and 54.7 per cent in summer as compared to broadcast application (26.1% in rabi, 34.2 in summer). Deep placement enhanced more retention in soil (up to 9.0% in rabi, 14.6% in summer) whereas broadcast application enhanced more retention in Azolla biomass that was grown in floodwater (up to 2.3 % in rabi, 4.3 % in summer). Use of 12 mm width nutriseed holder aiding deep placement at 5 cm depth was found suitable for deriving high yield and N use efficiency. (author)

  7. Development of an automatic sample changer and a data acquisition system

    International Nuclear Information System (INIS)

    Bianchini, Ricardo M.; Estevez, Jorge; Vollmer, Alberto E.; Iglicki, Flora A.

    1999-01-01

    An automatic electro-pneumatic sample changer with a rotating sample holder is described. The changer is coupled through an electronic interface with the data acquisition station. The software to automate the system has been designed. (author)

  8. The effect of simulated flash heating pasteurisation and Holder pasteurisation on human milk oligosaccharides.

    Science.gov (United States)

    Daniels, Brodie; Coutsoudis, Anna; Autran, Chloe; Amundson Mansen, Kimberly; Israel-Ballard, Kiersten; Bode, Lars

    2017-08-01

    Human milk oligosaccharides (HMOs) have important protective functions in human milk. A low-cost remote pasteurisation temperature-monitoring system has been designed using FoneAstra, a cell phone-based networked sensing system to monitor simulated flash heat pasteurisation. To compare the pasteurisation effect on HMOs of the FoneAstra FH method with the current Sterifeed Holder method used by human milk banks. Donor human milk samples (n = 48) were obtained from a human milk bank and pasteurised using the two pasteurisation methods. HMOs were purified from samples and labelled before separation using high-performance liquid chromatography. Concentrations of total HMOs, sialylated and fucosylated HMOs and individual HMOs using the two pasteurisation methods were compared using repeated-measures ANOVA. The study demonstrated no difference in total concentration of HMOs between the two pasteurisation methods and a small but significant increase in the total concentration of HMOs regardless of pasteurisation methods compared with controls (unpasteurised samples) (pmilk and therefore is a possible alternative for providing safely sterilised human milk for low- and middle-income countries.

  9. Design and burn-up analyses of new type holder for silicon neutron transmutation doping.

    Science.gov (United States)

    Komeda, Masao; Arai, Masaji; Tamai, Kazuo; Kawasaki, Kozo

    2016-07-01

    We have developed a new silicon irradiation holder with a neutron filter to increase the irradiation efficiency. The neutron filter is made of an alloy of aluminum and B4C particles. We fabricated a new holder based on the results of design analyses. This filter has limited use in applications requiring prolonged use due to a decrease in the amount of (10)B in B4C particles. We investigated the influence of (10)B reduction on doping distribution in a silicon ingot by using the Monte Carlo Code MVP. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Assessing the authority of political office-holders : The leadership capital index

    NARCIS (Netherlands)

    Bennister, Mark; t Hart, Paul; Worthy, Benjamin

    2015-01-01

    This article argues that the extent to which political office-holders can effectively attain and wield authority is a function of the stock of ‘leadership capital’. Drawing on the concept of political capital, the article defines leadership capital as aggregate authority composed of three

  11. Standard Procedure for Dose Assessment using the film holder NRPB/AERE and the film AGFA Monitoring 2/10

    International Nuclear Information System (INIS)

    Guillen, J.A.

    1998-07-01

    This paper describes the calculation method to assess dose and energy using the film holder from NRPB/AERE and the film Agfa Monitoring 2/10. Also includes all the steps since preparing the standard curve, fitting of calibration curve, dose assesment, description of filtration of the film holder and the form of the calibration curve

  12. Update of NIST half-life results corrected for ionization chamber source-holder instability

    International Nuclear Information System (INIS)

    Unterweger, M.P.; Fitzgerald, R.

    2014-01-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. - Highlights: • The NIST half-life data is corrected for sample positioning variations and refitted. • These results are reported and increased errors in the reported values are given. • Longer lived radionuclides are discussed

  13. Etching of Niobium Sample Placed on Superconducting Radio Frequency Cavity Surface in Ar/CL2 Plasma

    International Nuclear Information System (INIS)

    Upadhyay, Janardan; Phillips, Larry; Valente, Anne-Marie

    2011-01-01

    Plasma based surface modification is a promising alternative to wet etching of superconducting radio frequency (SRF) cavities. It has been proven with flat samples that the bulk Niobium (Nb) removal rate and the surface roughness after the plasma etchings are equal to or better than wet etching processes. To optimize the plasma parameters, we are using a single cell cavity with 20 sample holders symmetrically distributed over the cell. These holders serve the purpose of diagnostic ports for the measurement of the plasma parameters and for the holding of the Nb sample to be etched. The plasma properties at RF (100 MHz) and MW (2.45 GHz) frequencies are being measured with the help of electrical and optical probes at different pressures and RF power levels inside of this cavity. The niobium coupons placed on several holders around the cell are being etched simultaneously. The etching results will be presented at this conference.

  14. Etching of Niobium Sample Placed on Superconducting Radio Frequency Cavity Surface in Ar/CL2 Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Janardan Upadhyay, Larry Phillips, Anne-Marie Valente

    2011-09-01

    Plasma based surface modification is a promising alternative to wet etching of superconducting radio frequency (SRF) cavities. It has been proven with flat samples that the bulk Niobium (Nb) removal rate and the surface roughness after the plasma etchings are equal to or better than wet etching processes. To optimize the plasma parameters, we are using a single cell cavity with 20 sample holders symmetrically distributed over the cell. These holders serve the purpose of diagnostic ports for the measurement of the plasma parameters and for the holding of the Nb sample to be etched. The plasma properties at RF (100 MHz) and MW (2.45 GHz) frequencies are being measured with the help of electrical and optical probes at different pressures and RF power levels inside of this cavity. The niobium coupons placed on several holders around the cell are being etched simultaneously. The etching results will be presented at this conference.

  15. Increasing the Deep Drawability of Al-1050 Aluminum Sheet using Multi-Point Blank Holder

    Directory of Open Access Journals (Sweden)

    Gavas, M.

    2006-01-01

    Full Text Available Aluminum alloys have been widely used in the fields of automobile and aerospace industries. Due to their bad cold-formability in deep drawing, a lot of forming methods have been implemented to increase the drawing height and the limiting drawing rate (LDR. The conventional deep drawing process is limited to a certain limit drawing ratio beyond which failure will ensue. The purpose of this experimental study is to examine the possibilities of increasing this limitation using the multi-point blank holder. The results from the experiments showed that the multi-point blank holder is effective way to promote deep drawability of Al-1050 sheet.

  16. Precision tool holder with flexure-adjustable, three degrees of freedom for a four-axis lathe

    Science.gov (United States)

    Bono, Matthew J [Pleasanton, CA; Hibbard, Robin L [Livermore, CA

    2008-03-04

    A precision tool holder for precisely positioning a single point cutting tool on 4-axis lathe, such that the center of the radius of the tool nose is aligned with the B-axis of the machine tool, so as to facilitate the machining of precision meso-scale components with complex three-dimensional shapes with sub-.mu.m accuracy on a four-axis lathe. The device is designed to fit on a commercial diamond turning machine and can adjust the cutting tool position in three orthogonal directions with sub-micrometer resolution. In particular, the tool holder adjusts the tool position using three flexure-based mechanisms, with two flexure mechanisms adjusting the lateral position of the tool to align the tool with the B-axis, and a third flexure mechanism adjusting the height of the tool. Preferably, the flexures are driven by manual micrometer adjusters. In this manner, this tool holder simplifies the process of setting a tool with sub-.mu.m accuracy, to substantially reduce the time required to set the tool.

  17. An MR/MRI compatible core holder with the RF probe immersed in the confining fluid

    Science.gov (United States)

    Shakerian, M.; Balcom, B. J.

    2018-01-01

    An open frame RF probe for high pressure and high temperature MR/MRI measurements was designed, fabricated, and tested. The open frame RF probe was installed inside an MR/MRI compatible metallic core holder, withstanding a maximum pressure and temperature of 5000 psi and 80 °C. The open frame RF probe was tunable for both 1H and 19F resonance frequencies with a 0.2 T static magnetic field. The open frame structure was based on simple pillars of PEEK polymer upon which the RF probe was wound. The RF probe was immersed in the high pressure confining fluid during operation. The open frame structure simplified fabrication of the RF probe and significantly reduced the amount of polymeric materials in the core holder. This minimized the MR background signal detected. Phase encoding MRI methods were employed to map the spin density of a sulfur hexafluoride gas saturating a Berea core plug in the core holder. The SF6 was imaged as a high pressure gas and as a supercritical fluid.

  18. Inactivation of high-risk human papillomaviruses by Holder pasteurization: implications for donor human milk banking.

    Science.gov (United States)

    Donalisio, Manuela; Cagno, Valeria; Vallino, Marta; Moro, Guido E; Arslanoglu, Sertac; Tonetto, Paola; Bertino, Enrico; Lembo, David

    2014-01-01

    Several studies have recently reported the detection of oncogenic human papillomaviruses (HPV) in human milk of a minority of lactating mothers. These findings raised safety concerns in the context of human donor milk banking given the potential risk of HPV transmission to recipient infants. The aim of this study was to investigate whether the Holder pasteurization, a procedure currently in use in human donor milk banks for milk pasteurization, completely inactivates high-risk and low-risk HPV. HPV pseudoviruses (PsV) were generated, spiked into cell culture medium or donor human milk and subjected to thermal inactivation. HPV PsV infectivity and morphological integrity was analyzed by cell-based assay and by electron microscopy, respectively. The Holder pasteurization completely inactivated the infectivity of high-risk (types 16 and 18) and low-risk (type 6) HPV both in cell culture medium and in human milk causing PsV particle disassembly. The results presented here indicate that the Holder pasteurization is an efficient procedure to inactivate high-risk and low-risk HPV thus preventing the potential risk of their transmission through human donor milk.

  19. Smart Farming: Including Rights Holders for Responsible Agricultural Innovation

    OpenAIRE

    Kelly Bronson

    2018-01-01

    This article draws on the literature of responsible innovation to suggest concrete processes for including rights holders in the “smart” agricultural revolution. It first draws upon historical agricultural research in Canada to highlight how productivist values drove seed innovations with particular consequences for the distribution of power in the food system. Next, the article uses document analysis to suggest that a similar value framework is motivating public investment in smart farming i...

  20. 17 CFR 270.32a-2 - Exemption for initial period from vote of security holders on independent public accountant for...

    Science.gov (United States)

    2010-04-01

    ... from vote of security holders on independent public accountant for certain registered separate accounts... from vote of security holders on independent public accountant for certain registered separate accounts... 32(a) of the Act that selection of an independent public accountant shall have been submitted for...

  1. Assessment of conditions of the spent nuclear fuel stored in the stainless steel channel-holders

    International Nuclear Information System (INIS)

    Pesic, M.; Sotic, O.; Cupac, S.; Maksin, T.; Dasic, N.

    2003-01-01

    The IAEA technical co-operation project 'Safe Removal of Spent Fuel of the Vinca RA Research Reactor' is carried out at the Vinca Institute of Nuclear Sciences, Belgrade, Serbia and Montenegro, since January 2003. Present activities will provide up-to-date information on the conditions of the spent nuclear fuel, stored in the stainless steel channel-holders ('chekhols') and on the water quality in the storage basins. Water samples taken out from the chekhols and the basins are measured to determine their activity and chemical parameters. Until September 2003, about 1/3 of the chekhols containing spent fuel elements with initial enrichment of 2% and 80% of uranium were inspected. High activity of Cs-137 was found in several water samples taken out from chekhols. All water samples show very high electrical conductivity, while those taken from the basins show the presence of chlorides and aluminium ions, too. Information on established procedures and measuring results are given in this paper. The obtained results, so far, show that the spent nuclear fuel elements are leaking in about 10% of chekhols. (author)

  2. Development and installation of an automatic sample changer for neutron activation analysis

    International Nuclear Information System (INIS)

    Domienikan, Claudio; Lapolli, Andre L.; Schoueri, Roberto M.; Moreira, Edson G.; Vasconcellos, Marina B.A.

    2013-01-01

    A Programmable and Automatic Sample Changer was built and installed at the Neutron Activation Analysis Laboratory of the Nuclear and Energy Research Institute - IPEN-CNEN/SP, Brazil. This Automatic Sample Changer allows the fully automated measurement of up to 25 samples in one run. Basically it consists of an electronic circuit and C++ program that controls the positioning of a sample holder in two axes of motion (X and Y). Each sample is transported and positioned, one by one, inside the shielding coupled to a high-purity germanium (HPGe) radiation detector. A Canberra DSA-1000 Multichannel Analyzer coupled to the Genie 2000 software performs the data acquisition for analysis of the samples. When the counting is finished the results are saved in a hard disk of a PC computer. The sample is brought back by the sample holder to its initial position, and the next sample is carried to the shielding. The Sample Changer was designed and constructed at IPEN-CNEN/SP by employing national components and expertise. (author)

  3. Evaluation of the maxillary premolar roots dissociation using radiographic holders with conventional and digital radiography

    Directory of Open Access Journals (Sweden)

    Marcia Regina Ramalho da Silva Bardauil

    2010-09-01

    Full Text Available This in vivo study evaluated the dissociation quality of maxillary premolar roots combining variations of vertical and horizontal angulations by using X-ray holders (Rinn -XCP, and made a comparison between two types of intraoral radiography systems - conventional film (Kodak Insight, Rochester, USA and digital radiography (Kodak RVG 6100, Kodak, Rochester, USA. The study sample was comprised of 20 patients with a total of 20 maxillary premolars that were radiographed, using the paralleling angle technique (GP, with a 20º variation of the horizontal angle (GM and 25º variation of the horizontal angle combined with 15º vertical angle (GMV. Each image was independently analyzed by two experienced examiners. These examiners assigned a score to the diagnostic capability of root dissociation and the measurement of the distance between the apexes. Statistical data was derived using the Wilcoxon Signed Rank test, Friedman and T test. The means of the measured distances between buccal and lingual root apexes were greater for the GMV, which ranged from 2.3 mm to 3.3 mm. A statistically significant difference was found between GM and GMV when compared to GP with p < 0.01. An established best diagnostic dissociation roots image was found in the GMV. These results support the use of the anterior X-ray holders which offer a better combined deviation (GMV to dissociate maxillary premolar roots in both radiography systems.

  4. Custom fit 3D-printed brain holders for comparison of histology with MRI in marmosets.

    Science.gov (United States)

    Guy, Joseph R; Sati, Pascal; Leibovitch, Emily; Jacobson, Steven; Silva, Afonso C; Reich, Daniel S

    2016-01-15

    MRI has the advantage of sampling large areas of tissue and locating areas of interest in 3D space in both living and ex vivo systems, whereas histology has the ability to examine thin slices of ex vivo tissue with high detail and specificity. Although both are valuable tools, it is currently difficult to make high-precision comparisons between MRI and histology due to large differences inherent to the techniques. A method combining the advantages would be an asset to understanding the pathological correlates of MRI. 3D-printed brain holders were used to maintain marmoset brains in the same orientation during acquisition of ex vivo MRI and pathologic cutting of the tissue. The results of maintaining this same orientation show that sub-millimeter, discrete neuropathological features in marmoset brain consistently share size, shape, and location between histology and ex vivo MRI, which facilitates comparison with serial imaging acquired in vivo. Existing methods use computational approaches sensitive to data input in order to warp histologic images to match large-scale features on MRI, but the new method requires no warping of images, due to a preregistration accomplished in the technique, and is insensitive to data formatting and artifacts in both MRI and histology. The simple method of using 3D-printed brain holders to match brain orientation during pathologic sectioning and MRI acquisition enables rapid and precise comparison of small features seen on MRI to their underlying histology. Published by Elsevier B.V.

  5. Social Perception of Hydrogen Technologies: The View of Spanish Stake holders; Percepcion Social de las Tecnologias del Hidrogeno. La Vision de los Stakeholders Espanoles

    Energy Technology Data Exchange (ETDEWEB)

    Ferri Anglada, S.

    2013-07-01

    This technical report presents an overview of the social perception and vision of a sample of Spanish stake holders on hydrogen technologies. The study is based on the implementation of a survey, combining both quantitative and qualitative data. An ad hoc electronic survey was design to collect views and perceptions on several key factors regarding this innovative energy alternative. The group of experts participating (N=130) in the study, comes mainly from research centers, universities and private companies. The survey addresses three major themes: expert views, social acceptability, and contextual factors of hydrogen technologies. The aim is to capture both the current and the future scene as viewed by the experts on hydrogen technologies, identifying key factors in terms of changes, uncertainties, obstacles and opportunities. The objective is to identify potential key features for the introduction, development, promotion, implementation, and large-scale deployment of a highly successful energy proposal in countries such as Iceland, one of the pioneers in base its economy on hydrogen technologies. To conclude, this report illustrates the positive engagement of a sample of Spanish stake holders towards hydrogen technologies that may prove vital in the transition towards the Hydrogen Economy in Spain. (Author)

  6. 48 CFR 252.205-7000 - Provision of information to cooperative agreement holders.

    Science.gov (United States)

    2010-10-01

    ... has an agreement with the Defense Logistics Agency to furnish procurement technical assistance to business entities. (b) The Contractor shall provide cooperative agreement holders, upon their request, with... defense contracts. The list shall include the business address, telephone number, and area of...

  7. Recent validation tests of the Edelweiss II detector holders

    International Nuclear Information System (INIS)

    Schwamm, F.; Chapellier, M.; Herve, S.; Karolak, M.; Navick, X.-F.

    2006-01-01

    A very good understanding of noise sources is highly important for the sensitivity of a dark matter search experiment. One of these noise contributions in the Edelweiss experiment could be the microphonics and temperature variations caused by vibrations of the cryostat. Recent studies complement an earlier work in describing the effect of the Edelweiss II detector holders on the amplitude of the vibrations seen by the detector. The results of these studies will be presented in this article

  8. Insider patent holder licensing in an oligopoly market with different cost structures: Fixed-fee, royalty, and auction

    OpenAIRE

    Ming-Chung Chang

    2010-01-01

    The issue of the optimal licensing contract in firms having different cost structures is studied when the innovator is a producing patent holder who has three alternative licensing strategies, namely, the fixed-fee, royalty rate, and auction strategies. We conclude that the auction licensing strategy is not the best strategy when the innovator is a producing patent holder. This finding differs from that of Kabiraj (2004) where the auction licensing method is the optimal licensing strategy whe...

  9. Landscape effects on pollinator communities and pollination services in small-holder agroecosystems

    NARCIS (Netherlands)

    Zou, Yi; Bianchi, Felix J.J.A.; Jauker, Frank; Xiao, Haijun; Chen, Junhui; Cresswell, James; Luo, Shudong; Huang, Jikun; Deng, Xiangzheng; Hou, Lingling; Werf, van der Wopke

    2017-01-01

    Pollination by insects is key for the productivity of many fruit and non-graminous seed crops, but little is known about the response of pollinators to landscapes dominated by small-holder agriculture. Here we assess the relationships between landscape context, pollinator communities (density and

  10. Development of a short sample test facility for evaluating superconducting wires

    International Nuclear Information System (INIS)

    Singh, M.R.; Kulkarni, D.G.; Sahni, V.C.; Ravikumar, G.; Patel, K.L.

    2002-01-01

    In this paper we describe a short sample test facility we have set up at Bhabha Atomic Research Centre (BARC). This facility has been used to measure critical currents of NbTi/Cu composite superconducting wires by recording V versus I data at 4.2 K. It offers sample current as large as 1500 A and a transverse magnetic field up to 7.4 T. A power law, V ∼I n( H) is fitted to the resistive transition region to estimate the exponent n, which is a measure of the uniformity of superconducting filaments in composite wires. It is observed that inadequate thermal stabilization of sample wire results in thermal runaway, which limits the V-I data to∼ 2μ V . This in turn affects the reliability of estimated filament uniformity. To mitigate this problem, we have used a sample holder made of OFHC-Cu which enhances thermal stabilization of the sample. With this sample holder, the results of measurements carried out on wires developed by the Atomic Fuel Division, BARC show a high filament uniformity (n ∼ 58). (author)

  11. Do people really want freedom of choice? : Assessing preferences of pension holders

    NARCIS (Netherlands)

    van Dalen, Harry; Henkens, Kene

    2018-01-01

    Reforms of private pension plans across the world are involving the introduction of more options for pension holders to make choices to suit their preferences. Freedom of choice is not, however, a unidimensional concept despite being commonly perceived as such by policy makers. Using a unique panel

  12. Stability of Cortisol and Cortisone in Human Breast Milk During Holder Pasteurization

    NARCIS (Netherlands)

    van der Voorn, Bibian; de Waard, Marita; Dijkstra, Lisette R.; Heijboer, Annemieke C.; Rotteveel, Joost; van Goudoever, Johannes B.; Finken, Martijn J. J.

    2017-01-01

    Human donor milk is the feeding of choice for preterm infants, when own mother's milk is not available. Holder pasteurization is necessary to secure the safety of donor milk, although it can affect milk quality by reduction of nutritional and bioactive components. Recently, research has focused on

  13. Shielded scanning electron microscope for radioactive samples

    International Nuclear Information System (INIS)

    Crouse, R.S.; Parsley, W.B.

    1977-01-01

    A small commercial SEM had been successfully shielded for examining radioactive materials transferred directly from a remote handling facility. Relatively minor mechanical modifications were required to achieve excellent operation. Two inches of steel provide adequate shielding for most samples encountered. However, samples reading 75 rad/hr γ have been examined by adding extra shielding in the form of tungsten sample holders and external lead shadow shields. Some degradation of secondary electron imaging was seen but was adequately compensated for by changing operating conditions

  14. New tool holder design for cryogenic machining of Ti6Al4V

    Science.gov (United States)

    Bellin, Marco; Sartori, Stefano; Ghiotti, Andrea; Bruschi, Stefania

    2017-10-01

    The renewed demand of increasing the machinability of the Ti6Al4V titanium alloy to produce biomedical and aerospace parts working at high temperature has recently led to the application of low-temperature coolants instead of conventional cutting fluids to increase both the tool life and the machined surface integrity. In particular, the liquid nitrogen directed to the tool rake face has shown a great capability of reducing the temperature at the chip-tool interface, as well as the chemical interaction between the tool coating and the titanium to be machined, therefore limiting the tool crater wear, and improving, at the same time, the chip breakability. Furthermore, the nitrogen is a safe, non-harmful, non-corrosive, odorless, recyclable, non-polluting and abundant gas, characteristics that further qualify it as an environmental friendly coolant to be applied to machining processes. However, the behavior of the system composed by the tool and the tool holder, exposed to the cryogenics temperatures may represent a critical issue in order to obtain components within the required geometrical tolerances. On this basis, the paper aims at presenting the design of an innovative tool holder installed on a CNC lathe, which includes the cryogenic coolant provision system, and which is able to hinder the part possible distortions due to the liquid nitrogen adduction by stabilizing its dimensions through the use of heating cartridges and appropriate sensors to monitor the temperature evolution of the tool holder.

  15. Initial experience using a robotic-driven laparoscopic needle holder with ergonomic handle: assessment of surgeons' task performance and ergonomics.

    Science.gov (United States)

    Sánchez-Margallo, Juan A; Sánchez-Margallo, Francisco M

    2017-12-01

    The objective of this study is to assess the surgeons' performance and ergonomics during the use of a robotic-driven needle holder in laparoscopic suturing tasks. Six right-handed laparoscopic surgeons with different levels of experience took part in this study. Participants performed a set of three different intracorporeal suturing tasks organized in ten trials during a period of five weeks. Surgeons used both conventional (Conv) and robotic (Rob) laparoscopic needle holders. Precision using the surgical needle, quality of the intracorporeal suturing performance, execution time and leakage pressure for the urethrovesical anastomosis, as well as the ergonomics of the surgeon's hand posture, were analyzed during the first, fifth and last trials. No statistically significant differences in precision and quality of suturing performance were obtained between both groups of instruments. Surgeons required more time using the robotic instrument than using the conventional needle holder to perform the urethrovesical anastomosis, but execution time was significantly reduced after training ([Formula: see text] 0.05). There were no differences in leakage pressure for the anastomoses carried out by both instruments. After training, novice surgeons significantly improved the ergonomics of the wrist ([Formula: see text] 0.05) and index finger (Conv: 36.381[Formula: see text], Rob: 30.389[Formula: see text]; p = 0.024) when using the robotic instrument compared to the conventional needle holder. Results have shown that, although both instruments offer similar technical performance, the robotic-driven instrument results in better ergonomics for the surgeon's hand posture compared to the use of a conventional laparoscopic needle holder in intracorporeal suturing.

  16. Custom Fit 3D-Printed Brain Holders for Comparison of Histology with MRI in Marmosets

    Science.gov (United States)

    Guy, Joseph R.; Sati, Pascal; Leibovitch, Emily; Jacobson, Steven; Silva, Afonso C.; Reich, Daniel S.

    2015-01-01

    Background MRI has the advantage of sampling large areas of tissue and locating areas of interest in 3D space in both living and ex vivo systems, whereas histology has the ability to examine thin slices of ex vivo tissue with high detail and specificity. Although both are valuable tools, it is currently difficult to make high-precision comparisons between MRI and histology due to large differences inherent to the techniques. A method combining the advantages would be an asset to understanding the pathological correlates of MRI. New Method 3D-printed brain holders were used to maintain marmoset brains in the same orientation during acquisition of ex vivo MRI and pathologic cutting of the tissue. Results The results of maintaining this same orientation show that sub-millimeter, discrete neuropathological features in marmoset brain consistently share size, shape, and location between histology and ex vivo MRI, which facilitates comparison with serial imaging acquired in vivo. Comparison with Existing Methods Existing methods use computational approaches sensitive to data input in order to warp histologic images to match large-scale features on MRI, but the new method requires no warping of images, due to a preregistration accomplished in the technique, and is insensitive to data formatting and artifacts in both MRI and histology. Conclusions The simple method of using 3D-printed brain holders to match brain orientation during pathologic sectioning and MRI acquisition enables rapid and precise comparison of small features seen on MRI to their underlying histology. PMID:26365332

  17. Ultrafine-grained porous titanium and porous titanium/magnesium composites fabricated by space holder-enabled severe plastic deformation

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Yuanshen, E-mail: yuanshen.qi@monash.edu [Centre for Advanced Hybrid Materials, Department of Materials Engineering, Monash University, Clayton, Victoria 3800 (Australia); Contreras, Karla G. [Monash Institute of Medical Engineering, Faculty of Engineering, Monash University, Clayton, Victoria 3800 (Australia); Jung, Hyun-Do [Liquid Processing & Casting Technology R& D Group, Korea Institute of Industrial Technology, Incheon 406-840 (Korea, Republic of); Department of Materials Science and Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Kim, Hyoun-Ee [Department of Materials Science and Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Advanced Institutes of Convergence Technology, Seoul National University, Gwanggyo, Yeongtong-gu, Suwon-si, Gyeonggi-do 443-270 (Korea, Republic of); Lapovok, Rimma [Centre for Advanced Hybrid Materials, Department of Materials Engineering, Monash University, Clayton, Victoria 3800 (Australia); Estrin, Yuri, E-mail: yuri.estrin@monash.edu [Centre for Advanced Hybrid Materials, Department of Materials Engineering, Monash University, Clayton, Victoria 3800 (Australia); Laboratory of Hybrid Nanostructured Materials, NUST MISiS, Moscow 119490 (Russian Federation)

    2016-02-01

    Compaction of powders by equal channel angular pressing (ECAP) using a novel space holder method was employed to fabricate metallic scaffolds with tuneable porosity. Porous Ti and Ti/Mg composites with 60% and 50% percolating porosity were fabricated using powder blends with two kinds of sacrificial space holders. The high compressive strength and good ductility of porous Ti and porous Ti/Mg obtained in this way are believed to be associated with the ultrafine grain structure of the pore walls. To understand this, a detailed electron microscopy investigation was employed to analyse the interface between Ti/Ti and Ti/Mg particles, the grain structures in Ti particles and the topography of pore surfaces. It was found that using the proposed compaction method, high quality bonding between particles was obtained. Comparing with other powder metallurgy methods to fabricate Ti with an open porous structure, where thermal energy supplied by a laser beam or high temperature sintering is essential, the ECAP process conducted at a relatively low temperature of 400 °C was shown to produce unique properties. - Highlights: • Porous Ti and porous Ti/Mg composite scaffolds were fabricated successfully. • Space holder-enabled severe plastic deformation was first used in this application. • Silicon particles as sacrificial space holders were used for the first time. • Ultrafine-grained microstructure and good bonding between particles were obtained. • Good preosteoblast cell response to as-manufactured porous Ti was achieved.

  18. Preparation and characterization of porous Mg-Zn-Ca alloy by space holder technique

    Science.gov (United States)

    Annur, D.; Lestari, Franciska P.; Erryani, A.; Sijabat, Fernando A.; G. P. Astawa, I. N.; Kartika, I.

    2018-04-01

    Magnesium had been recently researched as a future biodegradable implant material. In the recent study, porous Mg-Zn-Ca alloys were developed using space holder technique in powder metallurgy process. Carbamide (10-20%wt) was added into Mg-6Zn-1Ca (in wt%) alloy system as a space holder to create porous structure material. Sintering process was done in a tube furnace under Argon atmosphere in 610 °C for 5 hours. Porous structure of the resulted alloy was examined using Scanning Electron Microscope (SEM), while the phase formation was characterized by X-ray diffraction analysis (XRD). Further, mechanical properties of porous Mg-Zn-Ca alloy was examined through compression testing. Microstructure characterization showed higher content of Carbamide in the alloy would give different type of pores. However, compression test showed that mechanical properties of Mg-Zn-Ca alloy would decrease significantly when higher content of carbamide was added.

  19. Investigation of holder pressure and size effects in micro deep drawing of rectangular work pieces driven by piezoelectric actuator.

    Science.gov (United States)

    Aminzahed, Iman; Mashhadi, Mahmoud Mosavi; Sereshk, Mohammad Reza Vaziri

    2017-02-01

    Micro forming is a manufacturing process to fabricate micro parts with high quality and a cost effective manner. Deep drawing could be a favorable method for production of complicated parts in macro and micro sizes. In this paper piezoelectric actuator is used as a novel approach in the field of micro manufacturing. Also, in current work, investigations are conducted with four rectangular punches and blanks with various thicknesses. Blank holder pressure effects on thickness distributions, punch force, and springback are studied. According to the results of this work, increasing of blank holder pressure in scaled deep drawing, in contrast to thickness of drawn part, leads to decrease in the punch forces and springback. Furthermore, it is shown that in micro deep drawing, the effects of holder pressure on mentioned parameters can be ignored. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Gasket-holder to put in place gaskets for connection of pipes with clamp fittings

    International Nuclear Information System (INIS)

    Fiori, R.

    1989-01-01

    Gasket-holder comprising 2 arms with tongues holding the gasket and fixing devices on a pipe clamp fitting and centering means. Application is made to fit circular gaskets on pipe with conic end in adverse environment [fr

  1. 13 CFR 120.651 - Claim to FTA by Registered Holder to replace Certificate.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Claim to FTA by Registered Holder to replace Certificate. 120.651 Section 120.651 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market Miscellaneous Provisions § 120.651 Claim to FTA by Registered...

  2. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders.

    Science.gov (United States)

    Özbilen, Sedat; Liebert, Daniela; Beck, Tilmann; Bram, Martin

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34-0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ(min) and σ(max) were varied systematically to estimate the fatigue limit (~4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. 12 CFR 611.1210 - Advance notices-commencement resolution and notice to equity holders.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Advance notices-commencement resolution and notice to equity holders. 611.1210 Section 611.1210 Banks and Banking FARM CREDIT ADMINISTRATION FARM..., within 10 days of adopting the commencement resolution, your bank and the other Farm Credit banks must...

  4. Electron emission of cathode holder of vacuum diode of an intense electron-beam accelerator and its effect on the output voltage

    Directory of Open Access Journals (Sweden)

    Xin-Bing Cheng

    2011-04-01

    Full Text Available The vacuum diode which is used to generate relativistic electron beams is one of the most important parts of a pulsed-power modulator. In this paper, the electron emission of cathode holder of a vacuum diode and its effect on the output voltage is investigated by experiments on an intense electron-beam accelerator with 180 ns full width at half maximum and 200–500 kV output voltage. First, the field emission is analyzed and the electric field of the vacuum chamber is calculated. Then, the flatness of the output voltage is discussed before and after adding an insulation plate when a water load is used. It is found that the electron emission at the edges of the cathode holder is the main reason to cause the change of the flatness. Last, a piece of polyester film is used as a target to further show the electron emission of the cathode holder. This analysis shows that decreasing the electron emission of the cathode holder in such a pulse power modulator could be a good way to improve the quality of the output voltage.

  5. Design and construction of a holder to the safety handling of Cs-137 to be used in cervix cancer treatments using intracavitary brachytherapy by afterloading

    International Nuclear Information System (INIS)

    Gonzales, E.; Lea, D.

    1996-01-01

    In venezuelan public hospitals where cervix cancer treatments are performed by means of Cs-137 manual afterloading systems, the handling of the sources is done with two type of holders, metallic and plastic, the plastic holders are pieces of induced serious radio-sanitary problem such as loser of the Cs-137 source and radioactive contamination in the treatment area, this has caused the interruption of the treatments in many hospitals. This interruption had a high social cost because of the thousands women waiting for intracavitary therapy. To start again with the treatments, the metallic holders were required but there were not enough funds in the budget, because of this problem in a short time IVIS'S health physics drew and made a low price source holder. (authors). 2 figs., 2 tabs

  6. Experimental verification of a deep drawing tool system for adaptive blank holder pressure distribution

    DEFF Research Database (Denmark)

    Tommerup, Søren; Endelt, Benny Ørtoft

    2012-01-01

    In deep drawing, the strain path in the blank during the forming process can be significantly affected by application of temporal and spatial variation of the blank holder force. In this study, an active tool system capable of controlling the distribution of the blank holder force is presented...... which can be integrated into existing stacked deep drawing tools without need for modification of the press. A working system is presented consisting of a controller, designated volume displacement cavity pressure supply units and a shimming plate. It is applied to the deep drawing of a rectangular...... to the conventional shimming method using paper or metal shims between the tool plates. The tool system’s ability to influence the material flow is investigated by performing a series of deep drawing experiments. Eight different cavity pressure schemes are applied during the punch stroke and the scheme’s effects...

  7. Smart Farming: Including Rights Holders for Responsible Agricultural Innovation

    Directory of Open Access Journals (Sweden)

    Kelly Bronson

    2018-02-01

    Full Text Available This article draws on the literature of responsible innovation to suggest concrete processes for including rights holders in the “smart” agricultural revolution. It first draws upon historical agricultural research in Canada to highlight how productivist values drove seed innovations with particular consequences for the distribution of power in the food system. Next, the article uses document analysis to suggest that a similar value framework is motivating public investment in smart farming innovations. The article is of interest to smart farming’s decision makers (from farmers to governance actors and a broader audience – anyone interested in engendering equity through innovation-led societal transitions.

  8. Novel sample preparation for operando TEM of catalysts

    International Nuclear Information System (INIS)

    Miller, Benjamin K.; Barker, Trevor M.; Crozier, Peter A.

    2015-01-01

    A new TEM sample preparation method is developed to facilitate operando TEM of gas phase catalysis. A porous Pyrex-fiber pellet TEM sample was produced, allowing a comparatively large amount of catalyst to be loaded into a standard Gatan furnace-type tantalum heating holder. The increased amount of catalyst present inside the environmental TEM allows quantitative determination of the gas phase products of a catalytic reaction performed in-situ at elevated temperatures. The product gas concentration was monitored using both electron energy loss spectroscopy (EELS) and residual gas analysis (RGA). Imaging of catalyst particles dispersed over the pellet at atomic resolution is challenging, due to charging of the insulating glass fibers. To overcome this limitation, a metal grid is placed into the holder in addition to the pellet, allowing catalyst particles dispersed over the grid to be imaged, while particles in the pellet, which are assumed to experience identical conditions, contribute to the overall catalytic conversion inside the environmental TEM cell. The gas within the cell is determined to be well-mixed, making this assumption reasonable. - Highlights: • High in-situ conversion of CO to CO 2 achieved by a novel TEM sample preparation method. • A 3 mm fiber pellet increases the TEM sample surface area by 50×. • Operando atomic resolution is maintained by also including a 3 mm grid in the sample. • Evidence for a well-mixed gas composition inside the ETEM cell is given

  9. An optimum source neutron spectrum and holder shape for extra-corporal treatment of liver cancer by BNCT

    International Nuclear Information System (INIS)

    Nievaart, Sander; Moss, Ray; Sauerwein, Wolfgang; Malago, Massimo; Kloosterman, Jan Leen; Hagen, Tim van der; Dam, Hugo van

    2006-01-01

    In extra-corporal treatment of liver cancer by BNCT, it is desired to have an as homogeneous as possible thermal neutron field throughout the organ. Previous work has shown that when using an epithermal neutron beam, the shape of the holder in which the liver is placed is the critical factor. This study develops the notion further as to what is the optimum neutron spectrum to perform such treatments. In the design calculations, when using Monte Carlo techniques, it is shown that when the expected contributions of the source neutrons in every part of the liver is calculated, a linear optimization scheme such as the Simplex method results in a mix of thermal and epithermal source neutrons to get the highest homogeneity for the thermal neutron field. This optimisation method is demonstrated in 3 holder shapes: cuboid, cylindrical and spherical with each 3 volumes of 2, 4 and 6 litres. A 10 cm thick cuboid model, irradiated from both sides gives the highest homogeneity. The spherical (rotating) holder has the lowest homogeneity but the highest contribution of every source neutron to the thermal neutrons in the liver. This can be advantageous when using a relatively small sized neutron beam with a low strength. (author)

  10. Novel sample preparation for operando TEM of catalysts.

    Science.gov (United States)

    Miller, Benjamin K; Barker, Trevor M; Crozier, Peter A

    2015-09-01

    A new TEM sample preparation method is developed to facilitate operando TEM of gas phase catalysis. A porous Pyrex-fiber pellet TEM sample was produced, allowing a comparatively large amount of catalyst to be loaded into a standard Gatan furnace-type tantalum heating holder. The increased amount of catalyst present inside the environmental TEM allows quantitative determination of the gas phase products of a catalytic reaction performed in-situ at elevated temperatures. The product gas concentration was monitored using both electron energy loss spectroscopy (EELS) and residual gas analysis (RGA). Imaging of catalyst particles dispersed over the pellet at atomic resolution is challenging, due to charging of the insulating glass fibers. To overcome this limitation, a metal grid is placed into the holder in addition to the pellet, allowing catalyst particles dispersed over the grid to be imaged, while particles in the pellet, which are assumed to experience identical conditions, contribute to the overall catalytic conversion inside the environmental TEM cell. The gas within the cell is determined to be well-mixed, making this assumption reasonable. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. SIMS analysis using a new novel sample stage

    International Nuclear Information System (INIS)

    Miwa, Shiro; Nomachi, Ichiro; Kitajima, Hideo

    2006-01-01

    We have developed a novel sample stage for Cameca IMS-series instruments that allows us to adjust the tilt of the sample holder and to vary the height of the sample surface from outside the vacuum chamber. A third function of the stage is the capability to cool sample to -150 deg. C using liquid nitrogen. Using this stage, we can measure line profiles of 10 mm in length without any variation in the secondary ion yields. By moving the sample surface toward the input lens, the primary ion beam is well focused when the energy of the primary ions is reduced. Sample cooling is useful for samples such as organic materials that are easily damaged by primary ions or electrons

  12. SIMS analysis using a new novel sample stage

    Energy Technology Data Exchange (ETDEWEB)

    Miwa, Shiro [Materials Analysis Lab., Sony Corporation, 4-16-1 Okata, Atsugi 243-0021 (Japan)]. E-mail: Shiro.Miwa@jp.sony.com; Nomachi, Ichiro [Materials Analysis Lab., Sony Corporation, 4-16-1 Okata, Atsugi 243-0021 (Japan); Kitajima, Hideo [Nanotechnos Corp., 5-4-30 Nishihashimoto, Sagamihara 229-1131 (Japan)

    2006-07-30

    We have developed a novel sample stage for Cameca IMS-series instruments that allows us to adjust the tilt of the sample holder and to vary the height of the sample surface from outside the vacuum chamber. A third function of the stage is the capability to cool sample to -150 deg. C using liquid nitrogen. Using this stage, we can measure line profiles of 10 mm in length without any variation in the secondary ion yields. By moving the sample surface toward the input lens, the primary ion beam is well focused when the energy of the primary ions is reduced. Sample cooling is useful for samples such as organic materials that are easily damaged by primary ions or electrons.

  13. Raising awareness about protection and control of nuclear materials held by 'small-scale holders'

    International Nuclear Information System (INIS)

    Ladsous, D.; Coulie, E.; Giorgio, M.

    2013-01-01

    In France, the activities carried out by the 'small-scale holders' of nuclear materials are organized by a specific regulatory system which defines in a detailed way their obligations and the means of control of the government. The first part of the article presents the legal framework relating to the use of nuclear materials by small-scale holders in civilian fields. The importance of the declaration of the nuclear material inventory is clearly emphasized and must be prepared and transmitted to the Institute for Radiological Protection and Nuclear Safety (IRSN) every year. The second part describes how this declaration is used to provide basic information for the competent Ministry and the inspectors to check the correct application of the regulatory requirements relating to physical protection and to the control of nuclear materials. Finally, the last part presents the on-site inspections carried out by sworn and accredited inspectors under the authority of the competent Authority, which provide an overall picture and allow an evaluation of the risks of theft, loss or diversion of these materials. (authors)

  14. Impact of the Flame-Holder Heat-Transfer Characteristics on the Onset of Combustion Instability

    KAUST Repository

    Hong, Seunghyuck

    2013-10-03

    In this article, we investigate the impact of heat transfer between the flame and the flameholder on the dynamic stability characteristics of a 50-kW backward-facing step combustor. We conducted a series of tests where two backward step blocks were used, made of ceramic and stainless steel, whose thermal conductivities are 1.06 and 12 W/m/K, respectively. Stability characteristics of the two flame-holder materials were examined using measurements of the dynamic pressure and flame chemiluminescence over a range of operating conditions. Results show that with the ceramic flameholder, the onset of instability is significantly delayed in time and, for certain operating conditions, disappears altogether, whereas with the higher conductivity material, the combustor becomes increasingly unstable over a range of operating conditions. We explain these trends using the heat flux through the flameholder and the change in the burning velocity near the step wall. Results suggest a potential approach using low-thermal-conductivity material near the flame-holder as passive dynamics suppression methods. Copyright © Taylor & Francis Group, LLC.

  15. Head holder using negative pressure bag packed with plastic beads in xenon CT CBF study

    International Nuclear Information System (INIS)

    Araki, Yuzo; Sakai, Noboru

    2003-01-01

    Employing analysis of cerebral blood flow (CBF) confidence maps, we investigated the usefulness of a head holder using a negative pressure bag packed with plastic beads in a xenon CT CBF study. A total of 272 consecutive patients for the CBF study were enrolled and classified into 3 groups: 88 patients with a negative pressure bag (M group), 87 patients with an air pillow (A group), and 97 patients with a sponge pillow (S group). The degree of effect of head movements on the CBF measurement in each patient was expressed as a confidence value (mean of the confidence values at one CT slice). The mean of confidence value in the M group (0.461) was statistically lower than that in the A group (0.866) and that in the S group (1.043). These findings showed that the head holder described here was useful for obtaining CBF maps of high quality in a xenon CT CBF study. (author)

  16. Determination of self shielding factors and gamma attenuation effects for tree ring samples

    International Nuclear Information System (INIS)

    Dagistan Sahin; Kenan Uenlue

    2012-01-01

    Determination of tree ring chemistry using Neutron Activation Analysis (NAA) is part of an ongoing research between Penn State University (PSU) and Cornell University, The Malcolm and Carolyn Wiener Laboratory for Aegean and Near Eastern Dendrochronology. Tree-ring chemistry yields valuable data for environmental event signatures. These signatures are a complex function of elemental concentration. To be certain about concentration of signature elements, it is necessary to perform the measurements and corrections with the lowest error and maximum accuracy possible. Accurate and precise values of energy dependent neutron flux at dry irradiation tubes and detector efficiency for tree ring sample are calculated for Penn State Breazeale Reactor (PSBR). For the calculation of energy dependent and self shielding corrected neutron flux, detailed model of the TRIGA Mark III reactor at PSU with updated fuel compositions was prepared using the MCNP utility for reactor evolution (MURE) libraries. Dry irradiation tube, sample holder and sample were also included in the model. The thermal flux self-shielding correction factors due to the sample holder and sample for were calculated and verified with previously published values. The Geant-4 model of the gamma spectroscopy system, developed at Radiation Science and Engineering Center (RSEC), was improved and absolute detector efficiency for tree-ring samples was calculated. (author)

  17. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    International Nuclear Information System (INIS)

    Walker, B. J.; Miller, D. T.

    2017-01-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  18. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    Energy Technology Data Exchange (ETDEWEB)

    Walker, B. J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, D. T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-06-06

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  19. 42 CFR 60.43 - Limitation, suspension, or termination of the eligibility of a HEAL lender or holder.

    Science.gov (United States)

    2010-10-01

    ... notice, sent by certified mail, specifying his or her intention to terminate the lender or holder's... that a HEAL lender fails to meet the statutory definition of an “eligible lender.” (d) This section...

  20. Running Mechanics and Metabolic Responses with Water Bottles and Bottle Belt Holders.

    Science.gov (United States)

    Vincent, Heather K; Zdziarski, Laura A; Fallgatter, Kyle; Negron, Giorgio; Chen, Cong; Leavitt, Trevor; Horodyski, MaryBeth; Wasser, Joseph G; Vincent, Kevin R

    2018-01-18

    This study determined whether differential kinematics, kinetics, rates of energy use and cardiopulmonary responses occurred during running with water bottles and bottle belt holders compared to running only. Trained runners (N=42; 27.2±6.4 yr) ran on an instrumented treadmill for four conditions in a randomized order: 1) control run (CON); 2) hand-held full water bottle (FULL, 16.9 fluid oz; 454 g); 3) hand-held half-full water bottle (HALF, 8.4 fluid oz.; 227 g); and 4) waist-worn bottle belt holder (BELT; hydration belt; 676 g). Gas exchange was measured using a portable gas analyzer. Kinetic and kinematic responses were determined via standard 3D videographic techniques. Interactions of limb side (right, left) by study condition (CON, FULL, HALF, BELT) were tested for rates of oxygen use and energy expenditure, and kinematic and kinetic parameters. No significant limb side × condition interactions existed for rates of oxygen use or energy expenditure. A significant interaction occurred with sagittal elbow flexion (pwater by hand or on the waist does not significantly change kinematics of running motion, rates of oxygen use and energy expenditure or cardiopulmonary measures over short durations. Runners are likely making adjustments to joint moments and powers that preserve balance and protect the lower extremity joints while maintaining the rates of oxygen use and energy expenditure.

  1. Naval Reserve Force: Cost and Benefit Analysis of Reducing the Number of Naval Surface Reserve Force Operating Budget Holders

    National Research Council Canada - National Science Library

    Young, Eric

    1997-01-01

    .... This thesis examines one of Commander Naval Surface Reserve Force's initiatives for reducing the current number of Operating Budget holder's Comptroller Departments without sacrificing efficiency...

  2. The Two-Year College as a First Choice, Second Chance Institution for Baccalaureate-Degree Holders

    Science.gov (United States)

    Townsend, Barbara K.

    2009-01-01

    This study focused on degree-seeking baccalaureate-degree holders at one two-year technical institute in the Midsouth to determine why they chose to study at the two-year college and how they compared their two-year college experience with their baccalaureate educational experience. Findings indicated the technical college was their first choice…

  3. Ecological Diversity of Soil Fauna as Ecosystem Engineers in Small-Holder Cocoa Plantation in South Konawe

    Directory of Open Access Journals (Sweden)

    Laode Muhammad Harjoni Kilowasid

    2012-05-01

    Full Text Available Taxa diversity within soil fauna functional groups can affected ecosystem functioning such as ecosystem engineers,which influence decomposition and nutrient cycling. The objective of this study is to describe ecological diversityvariation within soil fauna as ecosystem engineers in soil ecosystem of cocoa (Theobroma cacao L. plantation.Sampling was conducted during one year period from five different ages of plantation. Soil fauna removed from soilcore using hand sorting methods. A total of 39 genera of soil fauna as ecosystem engineers were found during thesestudies. Thirty five genera belong to the group of Formicidae (ants, three genera of Isoptera (termites, and onegenera of Oligochaeta (earthworms. Ecological diversity variation within ecosystem engineers was detected withSimpson indices for dominance and evenness. The highest diversity of ecosystem engineers was in the young ageof plantation. This study reinforces the importance biotic interaction which contributed to the distribution andabundance within soil fauna community as ecosystem engineers in small-holder cocoa plantation.

  4. A Modeling approach for analysis and improvement of spindle-holder-tool assembly dynamics

    OpenAIRE

    Budak, Erhan; Ertürk, A.; Erturk, A.; Özgüven, H. N.; Ozguven, H. N.

    2006-01-01

    The most important information required for chatter stability analysis is the dynamics of the involved structures, i.e. the frequency response functions (FRFs) which are usually determined experimentally. In this study, the tool point FRF of a spindle-holder-tool assembly is analytically determined by using the receptance coupling and structural modification techniques. Timoshenko’s beam model is used for increased accuracy. The spindle is also modeled analytically with elastic supports repre...

  5. Evaluation of the effect of a laparoscopic robotized needle holder on ergonomics and skills.

    Science.gov (United States)

    Bensignor, Thierry; Morel, Guillaume; Reversat, David; Fuks, David; Gayet, Brice

    2016-02-01

    Laparoscopy generates technical and ergonomics difficulties due to limited degrees of freedom (DOF) of forceps. To reduce this limitation, a new 5-mm robotized needle holder with two intracorporeal DOF, Jaimy(®), has been developed. The aim of this study was to evaluate its effects on ergonomics and skills. Fourteen surgeons including eight senior and six residents were crossover randomized and stratified based on experience. Three suturing tasks were performed with both Jaimy(®) and a classic needle holder (NH): task 1: Peg-Board; task 2: hexagonal suture; task 3: frontal suture. Postural ergonomics of the dominant arm were evaluated with an ergonomics score (RULA score) thanks to motion capture, and muscular ergonomics with electromyography of six muscular groups (flexor and extensor carpis, biceps, triceps, deltoid, trapeze). Performance outcomes are a quantitative and qualitative score, and skills outcomes are the measurement of the number of movements and the path length travelled by the instrument. The RULA score showed a statistically improved posture with Jaimy(®) (p < 0.001). The cumulative muscular workload (CMW) of four muscles was not different. However, the CMW was in favor of the NH for the flexor carpi ulnaris (p < 0.001) and the triceps (p = 0.027). The number of movements was not different (p = 0.39) although the path length was shorter with Jaimy(®) (p = 0.012). The score for task 1 was in favor of the NH (p = 0.006) with a higher quantity score. Task 2 score was not different (p = 0.086): The quality part of the score was in favor of Jaimy(®) (p = 0.009) and the quantity part was higher with the NH (p = 0.04). The score for task 3 was higher with Jaimy(®) (p = 0.001). This study suggests that the use of a robotized needle holder improves both posture and the quality of laparoscopic sutures.

  6. Power Holders and Social Dynamics of Participatory Development and Reconstruction: Cases from the Democratic Republic of Congo

    NARCIS (Netherlands)

    Kyamusugulwa, P.M.; Hilhorst, D.

    2015-01-01

    One of the challenges of participatory development and reconstruction programs is how and where to engage with power holders. This paper analyses the dynamics of power relations within a community-driven reconstruction program in the Democratic Republic of Congo. It shows that, in some

  7. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders

    Energy Technology Data Exchange (ETDEWEB)

    Özbilen, Sedat [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); Gazi University, Faculty of Technology, Department of Metallurgical and Materials Engineering, Teknikokullar, Ankara (Turkey); Liebert, Daniela [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); Beck, Tilmann [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); University of Kaiserslautern, Lehrstuhl für Werkstoffkunde (WKK), D-67663 Kaiserslautern (Germany); Bram, Martin, E-mail: m.bram@fz-juelich.de [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany)

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34–0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ{sub min} and σ{sub max} were varied systematically to estimate the fatigue limit (~ 4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD. - Highlights: • Systematic variation of the oxygen content from 0.34 to 0.58 wt.%. • Systematic study of the relationship between fatigue limit and oxygen content. • Critical oxygen equivalent seems to be 0.35 wt.% to avoid embrittlement. • Identification of the failure modes by light microscopy, SEM and EBSD.

  8. Advanced UXO Discrimination using Magnetometry: Understanding Remanent Magnetization

    Science.gov (United States)

    2009-09-01

    moments of steel samples. The MRIP comprises six three-component fluxgate magnetometers symmetrically distributed around a rotating sample holder. Samples...comprises six three- component fluxgate magnetometers symmetrically distributed around a rotating sample holder. Samples are placed on the holder... fluxgate magnetometers symmetrically distributed around a rotating sample holder. Samples are placed on the holder and are slowly spun through two

  9. Volatile Constituents, Inorganic Elements and Primary Screening of Bioactivity of Black Coral Cigarette Holders

    Directory of Open Access Journals (Sweden)

    Ganggang Shi

    2011-05-01

    Full Text Available Black corals (BC have been used for a long time in Chinese medicine, and may have some pharmaceutical functions when used as material for cigarette holders in southeast China. This study is aimed to investigate the bioactivities of volatile constituents in BC and to explore the folklore behind the use of BC cigarette holders (BCCHs. We extracted the volatile constituents of BC by supercritical fluid extraction (SFE with carbon dioxide (CO2-SFE, then identified and analyzed the constituents by gas chromatography-mass spectrometry (GC-MS. In total, 15 components were reliably identified in BC and found to be biologically active. These included triethyl phosphate, butylated hydroxytoluene, cedrol, n-hexadecanoic acid, squalene, and cholesterol. Meanwhile 13 inorganic elements (P, Ca, Mg, S, B, Si, Fe, Cu, Zn, Ba, etc. were determined by inductively coupled plasma spectrometer (ICPS. In the bioactivity tests, the BC extract (BCE showed a scavenging activity of 2,2-diphenyl-1-picrylhydrazyl free radicals and hydroxyl radicals by phenanthroline-Fe (II oxidation and moderate inhibition of Gram-positive microorganisms. The antioxidant and antimicrobial activities of BC, which are related to the active chemical composition, may explain the perceived benefit for cigarette smokers who use BCCHs.

  10. 48 CFR 339.7001 - Request for approval to make an award to other than a GSA BPA holder.

    Science.gov (United States)

    2010-10-01

    ... Use of General Services Administration Blanket Purchase Agreements for Independent Risk Analysis... micro-purchase threshold, that obtaining the required services from a source other than a GSA BPA holder... include additional supporting rationale to document the best value decision, as appropriate. ...

  11. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 158B/159A

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States); Walker, Billy Justin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-11-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 158B/159A which were measured by the Radiation Measurements Laboratory (RML).

  12. Safeguards-relevant information collection from small holders – experiences and challenges

    International Nuclear Information System (INIS)

    Sundén, Erika; Dufva, Martina; Dahlberg, Joakim

    2015-01-01

    A number of universities, research institutions, hospitals, and other businesses are in possession of relatively small amounts of nuclear material. In some cases the material is in activities related to the nuclear fuel cycle, but there is also a wide variety of other applications. Regardless of application, material accountancy must be reported to the European Commission (EC) and, in Sweden, to the Swedish Radiation Safety Authority (SSM). However, checking the completeness and correctness of the reports from operators with very small amounts of nuclear material can easily be forgotten or viewed as being less important. Starting in the beginning of 2013 SSM increased its effort in this area and began working more actively gathering information and checking its correctness. Informing the operators in possession of nuclear material of the rules and regulations is a major part of this work, as it has been noted that the knowledge level of safeguarding nuclear material in many locations is very low. This paper will give a description of the work being performed by SSM to ensure that information related to the possession of nuclear material are gathered and correctly declared. It will give an overview of the different procedures that are applied to different categories of small holders in Sweden (where the differences are mostly due to historical reasons). It will also entail some of the challenges met along the way; such as explaining to radiographers that for nuclear non-proliferation purposes it is the shielding uranium container which is of interest, not the isotope emitting the radiation. What we have experienced being the major differences between collecting information from small holders as compared to larger nuclear facilities will also be outlined. The paper ends with an outline for future work.

  13. The role of stake holders in the Italian debate on the national radioactive waste deposit

    International Nuclear Information System (INIS)

    Cantone, Marie C.

    2008-01-01

    Full text: In early 2003, following an increased concern about the international terrorist threat, the Italian Government declared an emergency status for national nuclear installations, and in particular for radioactive waste deposits. A working group of experts - mainly from the Society for the Management of Nuclear Installations (SOGIN) and the Agency for New Technologies, Energy and Environment (ENEA) - was appointed and charged with the analysis of the technical aspects implied in the creation of a repository to host permanently LLRW and MLRW as well as to host temporarily HLRW. In November 2003 the Italian Government passed a decree to authorize the creation of a national nuclear waste repository within a geological salt deposit in the territory of Scanzano Jonico, in the Basilicata Region. The decision was made without any negotiation with the local population and the authorities of Scanzano Jonico. The lack of transparent communication and the attempt to impose the project 'from the top' was perceived as a 'deceptive strategy'. The population of the entire region spontaneously organized a mass protest movement against the project; blockades were carried out on the major highway connecting Northern to Southern Italy and the controversy gained the attention of the national mass media. Two weeks later, the Italian government withdrew the decree. Presently, the Italian nuclear waste is distributed over more than 20 locations in 11 different Regions, and the creation of a national disposal site has been postponed. The present study aims at highlighting the reasons behind social conflicts on nuclear waste risks. We will examine the attitudes and the communication strategies of the different stake holders which took part in the public debate on the Italian nuclear waste dump. Drawing on methodologies used in media studies, we are carrying out a quantitative and qualitative analysis of the main national and local newspapers in order to draw a 'map' of the

  14. Sample vial inserts: A better approach for sampling heterogeneous slurry samples in the SRS Defense Waste Processing Facility

    International Nuclear Information System (INIS)

    Coleman, C.J.; Goode, S.R.

    1996-01-01

    A convenient and effective new approach for analyzing DWPF samples involves the use of inserts with volumes of 1.5--3 ml placed in the neck of 14 ml sample vials. The inserts have rims that conform to the rim of the vials so that they sit straight and stable in the vial. The DWPF tank sampling system fills the pre-weighed insert rather than the entire vial, so the vial functions only as the insert holder. The shielded cell operator then removes the vial cap and decants the insert containing the sample into a plastic bottle, crucible, etc., for analysis. Inert materials such as Teflon, plastic, and zirconium are used for the insert so it is unnecessary to separate the insert from the sample for most analyses. The key technique advantage of using inserts to take DWPF samples versus filling sample vials is that it provides a convenient and almost foolproof way of obtaining and handling small volumes of slurry samples in a shielded cell without corrupting the sample. Since the insert allows the entire sample to be analyzed, this approach eliminates the errors inherent with subsampling heterogeneous slurries that comprise DWPF samples. Slurry samples can then be analyzed with confidence. Analysis times are dramatically reduced by eliminating the drying and vitrification steps normally used to produce a homogeneous solid sample. Direct dissolution and elemental analysis of slurry samples are achieved in 8 hours or less compared with 40 hours for analysis of vitrified slurry samples. Comparison of samples taken in inserts versus full vials indicate that the insert does not significantly affect sample composition

  15. Whether power holders construe their power as responsibility or opportunity influences their tendency to take advice from others

    NARCIS (Netherlands)

    de Wit, F.R.C.; Scheepers, D.; Ellemers, N.; Sassenberg, Kai; Scholl, Annika

    Empirical evidence suggests that power elicits a generic tendency to disregard advice. We examined different responses power holders may show in their tendency to take advice depending on the construal of power. We report a field study and an experiment among managers and other powerful

  16. Heat Transfer Analysis of an Optimized, Flexible Holder System for Freeze-Drying in Dual Chamber Cartridges Using Different State-of-the-Art PAT Tools.

    Science.gov (United States)

    Korpus, Christoph; Pikal, Michael; Friess, Wolfgang

    2016-11-01

    The aim of this study was to determine the heat transfer characteristics of an optimized flexible holder device, using Tunable Diode Laser Absorption Spectroscopy, the Pressure Rise Test, and the gravimetric procedure. Two different controlled nucleation methods were tested, and an improved sublimation process, "preheated plate," was developed. Tunable Diode Laser Absorption Spectroscopy identified an initial sublimation burst phase. Accordingly, steady-state equations were adapted for the gravimetric procedure, to account for this initial non-steady-state period. The heat transfer coefficient, K DCC , describing the transfer from the holder to the DCC, was the only heat transfer coefficient showing a clear pressure dependence with values ranging from 3.81E-04 cal/(g·cm 2 ·K) at 40 mTorr to 7.38E-04 cal/(g·cm 2 ·K) at 200 mTorr. The heat transfer coefficient, K tot , reflecting the overall energy transfer via the holder, increased by around 24% from 40 to 200 mTorr. This resulted in a pressure-independent sublimation rate of around 42 ± 1.06 mg/h over the whole pressure range. Hence, this pressure-dependent increase in energy transfer completely compensated the decrease in driving force of sublimation. The "flexible holder" shows a substantially reduced impact of atypical radiation, improved drying homogeneity, and ultimately a better transferability of the freeze-drying cycle for process optimization. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. Development of a versatile TEM specimen holder for the characterization of photocatalytic materials

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Langhammer, C.; Hansen, Thomas Willum

    2011-01-01

    conventional TEM analysis on photocatalysts with several in situ TEM techniques including environmental TEM (ETEM), in situ photo activation and localized surface plasmon resonance (LSPR) spectroscopy [3-4]. These experiments are facilitated by the construction of a specimen holder capable of illuminating....../on nanomaterials and thin films. We present results from combined ETEM-LSPR studies of thermally-induced catalytic phenomena and on metal nanoparticle sintering, an important process in catalysis, which we study in situ in both real and model systems by means of indirect nanoplasmonic sensing and ETEM....

  18. Sample preparation for the HAW project and experimental results from the HFR

    International Nuclear Information System (INIS)

    Garcia Celma, A.; Wees, H. van; Miralles, L.

    1990-09-01

    This report deals with the preparation and analysis of samples, during the period May 1989-November 1989, for the High-Active Waste (HAW) project, a large-scale in situ test being performed underground in the Asse salt mine, Remlingen FRG. The development of the technical procedures required, and the scientific results, which regard mostly characterization of Potasas del Llobregat sample, are reported. Prior to using the samples in both the H.A.W. and the H.F.R. experiments they have to be machined to fit their holders. Technical improvements for machining samples of salt are reported. (H.W.). 9 refs.; 68 figs.; 10 tabs

  19. Specimen holder for an electron microscope and device and method for mounting a specimen in an electron microscope

    NARCIS (Netherlands)

    Zandbergen, H.W.; Latenstein van Voorst, A.; Westra, C.; Hoveling, G.H.

    1996-01-01

    A specimen holder for an electron microscope, comprising a bar-shaped body provided adjacent one end with means for receiving a specimen, with means being present for screening the specimen from the environment at least temporarily in airtight and moisture-proof manner in a first position, which

  20. Impact of Small Holder Dairy Farm on the Air Quality in Gunungpati District, Semarang Municipality

    Science.gov (United States)

    Widiastuti, E.; Kustono; Adiarto; Nurliyani; Sugiharto, S.

    2018-02-01

    The study aimed to investigate the impact of small holder dairy farm on the air quality in the farm and surrounding area. The study was conducted in three farmer groups in the District of Gunungpati, including the farmer groups in the villages of Nangkasawit, Plalangan and Sumurejo. Samplings of air quality were conducted in four points (locations), i.e., inside the barn, 100 m, 200 m and 300 m from the area of farm. Parameters observed were emission of NH3 CO2, H2S and CH4. Results showed that the levels of NH3 in the barn, 100 m, 200 m and 300 m from the farm area in Nangkasawit village were 0.211, 0.107, 0.104 and 0,035 ppm, respectively. The levels of NH3 in Plalangan village were 0.289, 0.231, 0.13 and 0.108 ppm, respectively, and in Sumurejo village were 0.109, 0.110, 0.082 and 0.046 ppm, respectively. The levels of H2S in Nangkasawit, Plalangan and Sumurejo villages at the entire points of observations were air quality was better (lower contamination) with the farther distance of locations from the barn.

  1. Determinants of Increasing Duration of First Unemployment among First Degree Holders in Rwanda: A Logistic Regression Analysis

    Science.gov (United States)

    Niragire, François; Nshimyiryo, Alphonse

    2017-01-01

    Unexpectedly, the duration of first unemployment among first degree holders has quickly increased in Rwanda after considerable loss of the skilled labour during the war and Genocide perpetrated against Tutsi in 1994. The time it takes a higher education graduate to land a first employment is a key indicator for the evaluation of and optimal…

  2. SEM technique for imaging and measuring electronic transport in nanocomposites based on electric field induced contrast

    Science.gov (United States)

    Jesse, Stephen [Knoxville, TN; Geohegan, David B [Knoxville, TN; Guillorn, Michael [Brooktondale, NY

    2009-02-17

    Methods and apparatus are described for SEM imaging and measuring electronic transport in nanocomposites based on electric field induced contrast. A method includes mounting a sample onto a sample holder, the sample including a sample material; wire bonding leads from the sample holder onto the sample; placing the sample holder in a vacuum chamber of a scanning electron microscope; connecting leads from the sample holder to a power source located outside the vacuum chamber; controlling secondary electron emission from the sample by applying a predetermined voltage to the sample through the leads; and generating an image of the secondary electron emission from the sample. An apparatus includes a sample holder for a scanning electron microscope having an electrical interconnect and leads on top of the sample holder electrically connected to the electrical interconnect; a power source and a controller connected to the electrical interconnect for applying voltage to the sample holder to control the secondary electron emission from a sample mounted on the sample holder; and a computer coupled to a secondary electron detector to generate images of the secondary electron emission from the sample.

  3. Technique for preparation of transmission electron microscope specimens from wire samples of Al and Al-Al2O3 alloys

    DEFF Research Database (Denmark)

    Lindbo, Jørgen

    1966-01-01

    A technique for thinning 1 mm wire samples of aluminium and aluminium-alumina alloys for transmission electron microscopy is described. The essential feature of the technique, which involves spark machining and electropolishing in a polytetrafluoroethylene holder followed by chemical polishing...

  4. Determination of low concentrations of uranium in granite samples by X-ray fluorescence

    International Nuclear Information System (INIS)

    Roca, M.; Diaz-Guerra, J.P.

    1981-01-01

    An x-ray fluorescence method for the determination of uranium in granite samples for concentrations ranging from 3 to 100 ppm U 3 O 8 has been developed. To this purpose a sample holder, specially designed, allowing the irradiation of sample surfaces 42.5 mm in diameter and a molybdenum tube operating with a power of 2700 W (90 kV, 30 mA) are used. The background influence and the spectral interferences from rubidium and strontium have been taken into account and specific correction coefficients have been computed. A Basic program facilitates the report of the analytical results. (author)

  5. 14 CFR 193.17 - How must design and production approval holders handle information they receive from the FAA...

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false How must design and production approval... REGULATIONS PROTECTION OF VOLUNTARILY SUBMITTED INFORMATION § 193.17 How must design and production approval... under § 193.9(a)(2) to the holders of design approvals of production approvals issued by the FAA, the...

  6. Sample mounting and transfer for coupling an ultrahigh vacuum variable temperature beetle scanning tunneling microscope with conventional surface probes

    International Nuclear Information System (INIS)

    Nafisi, Kourosh; Ranau, Werner; Hemminger, John C.

    2001-01-01

    We present a new ultrahigh vacuum (UHV) chamber for surface analysis and microscopy at controlled, variable temperatures. The new instrument allows surface analysis with Auger electron spectroscopy, low energy electron diffraction, quadrupole mass spectrometer, argon ion sputtering gun, and a variable temperature scanning tunneling microscope (VT-STM). In this system, we introduce a novel procedure for transferring a sample off a conventional UHV manipulator and onto a scanning tunneling microscope in the conventional ''beetle'' geometry, without disconnecting the heating or thermocouple wires. The microscope, a modified version of the Besocke beetle microscope, is mounted on a 2.75 in. outer diameter UHV flange and is directly attached to the base of the chamber. The sample is attached to a tripod sample holder that is held by the main manipulator. Under UHV conditions the tripod sample holder can be removed from the main manipulator and placed onto the STM. The VT-STM has the capability of acquiring images between the temperature range of 180--500 K. The performance of the chamber is demonstrated here by producing an ordered array of island vacancy defects on a Pt(111) surface and obtaining STM images of these defects

  7. A matter of focus: Power-holders feel more responsible after adopting a cognitive other-focus, rather than a self-focus

    NARCIS (Netherlands)

    Scholl, Annika; Sassenberg, Kai; Scheepers, Daan; Ellemers, Naomi|info:eu-repo/dai/nl/086631276; de Wit, Frank

    Social power implies responsibility. Yet, power-holders often follow only their own interests and overlook this responsibility. The present research illuminates how a previously adopted cognitive focus guides perceived responsibility when a person receives high (vs. low) power. In three experiments,

  8. Highly porous open cell Ti-foam using NaCl as temporary space holder through powder metallurgy route

    International Nuclear Information System (INIS)

    Jha, Nidhi; Mondal, D.P.; Dutta Majumdar, J.; Badkul, Anshul; Jha, A.K.; Khare, A.K.

    2013-01-01

    Highlights: ► NaCl crystals has been used as space holder. ► Variation of NaCl:Ti ratio varies porosity (65–80%). ► NaCl is cubic but the cells are spherical. ► Two types of pores: micro and macro pores are obtained. ► Foams are suitable for bones scaffolds and engineering applications. - Abstract: Open cell Titanium-foam (Ti-foam) with varying porosities (65–80%) was prepared using sodium chloride (NaCl) particles as space holder through powder metallurgy route. In order to ensure sufficient handling strength in cold compacted pallets, 2 wt.% polyvinyl alcohol (PVA) solutions (5 wt.% PVA in water) was mixed with the mixture of Ti and NaCl powders prior to cold compaction. After sintering, NaCl salt was removed by dissolving it in hot water. Detailed Energy dispersive X-ray (EDX) analysis and X-ray diffraction studies of the prepared Ti-foams were conducted to examine any physical and chemical changes in the phase constituents. The micro-architectural characteristics, density vis-a-vis porosity, and compressive deformation behavior of the synthesized foams were evaluated to examine their suitability as biomaterial and engineering applications

  9. Application of bias correction methods to improve U3Si2 sample preparation for quantitative analysis by WDXRF

    International Nuclear Information System (INIS)

    Scapin, Marcos A.; Guilhen, Sabine N.; Azevedo, Luciana C. de; Cotrim, Marycel E.B.; Pires, Maria Ap. F.

    2017-01-01

    The determination of silicon (Si), total uranium (U) and impurities in uranium-silicide (U 3 Si 2 ) samples by wavelength dispersion X-ray fluorescence technique (WDXRF) has been already validated and is currently implemented at IPEN's X-Ray Fluorescence Laboratory (IPEN-CNEN/SP) in São Paulo, Brazil. Sample preparation requires the use of approximately 3 g of H 3 BO 3 as sample holder and 1.8 g of U 3 Si 2 . However, because boron is a neutron absorber, this procedure precludes U 3 Si 2 sample's recovery, which, in time, considering routinely analysis, may account for significant unusable uranium waste. An estimated average of 15 samples per month are expected to be analyzed by WDXRF, resulting in approx. 320 g of U 3 Si 2 that would not return to the nuclear fuel cycle. This not only impacts in production losses, but generates another problem: radioactive waste management. The purpose of this paper is to present the mathematical models that may be applied for the correction of systematic errors when H 3 BO 3 sample holder is substituted by cellulose-acetate {[C 6 H 7 O 2 (OH) 3-m (OOCCH 3 )m], m = 0∼3}, thus enabling U 3 Si 2 sample’s recovery. The results demonstrate that the adopted mathematical model is statistically satisfactory, allowing the optimization of the procedure. (author)

  10. Development technique for deep drawing without blank holder to produce circular cup of brass alloy

    OpenAIRE

    Ali Hassan Saleh; Ammer Khalaf Ali

    2015-01-01

    Of this technique compared to the conventional deep drawing is that the circular cup can be carried out in single action press with limit In this paper a new mechanism for deep drawing was proposed to produce circular cup from thin plate without blank holder. In this technique the die assembly includes punch, die and die-punch. A 2D axisymmetric finite element model was built using DEFORM software. Effect of die geometry (half- cone angle) on maximum load, thickness distribution, strain distr...

  11. Use of a 55Fe radioisotope for the determination of titanium in laterite samples via energy dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    La Brecque, J.J.

    1978-01-01

    A rapid method for the determination of titanium in geochemical samples using a 55 Fe radioisotope at the extraction source coupled to a Si(Li) detector and a PDP-11/05 computer is described. A representative sample of about 200 g is ground in a large mortar and pestle before it is passed through a 20 mesh sieve. The 20 mesh sample is mixed thoroughly and quartered, then a 5 g subsample is passed completely through a 150 mesh sieve. Both the sample and internal standard K 2 Cr 2 O 7 are dried at 105 deg C before a 250 mg portion of each is weighed and thoroughly mixed. Three 50-100 mg portions are placed in separate sample holders. The sample holder is a simple card with a 1.5 cm diameter opening in which the sample is inserted between two layers of Magic Scotch tape. The relative standard deviation for a thin sample about 100 mg in weight is less than 4% and it is achieved in a fluorescent time of 100 sec. Data are given for the use of two different internal standards, KBrO 2 and K 2 Cr 2 O 7 , the latter being more precise. The values for five international reference standards determined by this method are in agreement with the reported values. (T.G.)

  12. Update of NIST half-life results corrected for ionization chamber source-holder instability.

    Science.gov (United States)

    Unterweger, M P; Fitzgerald, R

    2014-05-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. © 2013 Published by Elsevier Ltd.

  13. SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

    International Nuclear Information System (INIS)

    Islam, N; Xiong, Z; Vijayan, S; Rudin, S; Bednarek, D

    2015-01-01

    Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with an air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant

  14. SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Islam, N; Xiong, Z; Vijayan, S; Rudin, S; Bednarek, D [Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY (United States)

    2015-06-15

    Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with an air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant.

  15. A 'smart' tube holder enables real-time sample monitoring in a standard lab centrifuge.

    Science.gov (United States)

    Hoang, Tony; Moskwa, Nicholas; Halvorsen, Ken

    2018-01-01

    The centrifuge is among the oldest and most widely used pieces of laboratory equipment, with significant applications that include clinical diagnostics and biomedical research. A major limitation of laboratory centrifuges is their "black box" nature, limiting sample observation to before and after centrifugation. Thus, optimized protocols require significant trial and error, while unoptimized protocols waste time by centrifuging longer than necessary or material due to incomplete sedimentation. Here, we developed an instrumented centrifuge tube receptacle compatible with several commercial benchtop centrifuges that can provide real-time sample analysis during centrifugation. We demonstrated the system by monitoring cell separations during centrifugation for different spin speeds, concentrations, buffers, cell types, and temperatures. We show that the collected data are valuable for analytical purposes (e.g. quality control), or as feedback to the user or the instrument. For the latter, we verified an adaptation where complete sedimentation turned off the centrifuge and notified the user by a text message. Our system adds new functionality to existing laboratory centrifuges, saving users time and providing useful feedback. This add-on potentially enables new analytical applications for an instrument that has remained largely unchanged for decades.

  16. [The randomized controlled trial of the treatment for clavicular fracture by rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation].

    Science.gov (United States)

    Bi, Hong-zheng; Yang, Mao-qing; Tan, Yuan-chao; Fu, Song

    2008-07-01

    To study the curative effect and safety of rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation in treating clavicular fracture. All 201 cases of clavicular fractures were randomly divided into treatment group (101 cases) and control group (100 cases). The treatment group was treated by rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation. The control group was treated by open reduction and internal fixation with Kirschner pin. All cases were followed up for 4 to 21 months (mean 10.6 months). SPSS was used to analyze clinic healing time of fracture and shoulder-joint function in both two groups. After operation, 101 cases of treatment group achieved union of fracture and the clinical healing time was 28 to 49 days (mean 34.5+/-2.7 days). In control group,there were 4 cases with nonunion of fracture,the other 96 cases were union,the clinical healing time was 36 to 92 days (mean 55.3+/-4.8 days). The excellent and good rate of shoulder-joint function was 100% in treatment group and 83% in control group. By t-test and chi2-test, there was significant difference between the two groups in curative effect (Pmanual reduction with forceps holder and retrograde pinning transfixation can be used in various kinds of clavicular shaft fracture, with many virtues such as easy operation, reliable fixation, short union time of fracture, good functional recovery of shoulder-joint and no incision scar affecting appearance.

  17. 14 CFR 120.11 - Refusal to submit to a drug or alcohol test by a Part 61 certificate holder.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Refusal to submit to a drug or alcohol test...: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Individuals Certificated Under Parts 61, 63, and 65 § 120.11 Refusal to submit to a drug or alcohol test by a Part 61 certificate holder. (a) This...

  18. 14 CFR 120.15 - Refusal to submit to a drug or alcohol test by a Part 65 certificate holder.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Refusal to submit to a drug or alcohol test...: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Individuals Certificated Under Parts 61, 63, and 65 § 120.15 Refusal to submit to a drug or alcohol test by a Part 65 certificate holder. (a) This...

  19. 14 CFR 120.13 - Refusal to submit to a drug or alcohol test by a Part 63 certificate holder.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Refusal to submit to a drug or alcohol test...: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Individuals Certificated Under Parts 61, 63, and 65 § 120.13 Refusal to submit to a drug or alcohol test by a Part 63 certificate holder. (a) This...

  20. Probing electronic interactions using electron tunneling

    Indian Academy of Sciences (India)

    pratap

    Sample preparation. Chamber. Sample manipulators. Vibration Isolation. Table. Cryostat. Load lock. STM Head. Magnet. Sample holder. Tip. Tip holder. Piezo electric tube. Coarse positioner. Macor. Cu housing for sample holder. PCB. Cu shielding can. Steel studs. Our Toy: The TIFR milli-Kelvin STM. Lowest temperature:.

  1. Systems and methods for large-scale nanotemplate and nanowire fabrication

    KAUST Repository

    Vidal, Enrique Vilanova; Alfadhel, Ahmed; Ivanov, Iurii; Kosel, Jü rgen

    2016-01-01

    Systems and methods for largescale nanotemplate and nanowire fabrication are provided. The system can include a sample holder and one or more chemical containers fluidly connected to the sample holder. The sample holder can be configured to contain

  2. 26 CFR 1.860E-1 - Treatment of taxable income of a residual interest holder in excess of daily accruals.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Treatment of taxable income of a residual interest holder in excess of daily accruals. 1.860E-1 Section 1.860E-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment...

  3. Determinants of the Job Satisfaction of PhD Holders: An Analysis by Gender, Employment Sector, and Type of Satisfaction in Spain

    Science.gov (United States)

    Escardíbul, Josep-Oriol; Afcha, Sergio

    2017-01-01

    We analyze the determinants of job satisfaction of PhD holders in Spain. Specifically, we consider overall job satisfaction as well as basic and motivational satisfaction, following Herzberg's typology (based on Maslow's hierarchy of needs). Using representative data for Spain's PhD population--collected from the Spanish Survey on Human Resources…

  4. Moving Object Detection Using Scanning Camera on a High-Precision Intelligent Holder

    Science.gov (United States)

    Chen, Shuoyang; Xu, Tingfa; Li, Daqun; Zhang, Jizhou; Jiang, Shenwang

    2016-01-01

    During the process of moving object detection in an intelligent visual surveillance system, a scenario with complex background is sure to appear. The traditional methods, such as “frame difference” and “optical flow”, may not able to deal with the problem very well. In such scenarios, we use a modified algorithm to do the background modeling work. In this paper, we use edge detection to get an edge difference image just to enhance the ability of resistance illumination variation. Then we use a “multi-block temporal-analyzing LBP (Local Binary Pattern)” algorithm to do the segmentation. In the end, a connected component is used to locate the object. We also produce a hardware platform, the core of which consists of the DSP (Digital Signal Processor) and FPGA (Field Programmable Gate Array) platforms and the high-precision intelligent holder. PMID:27775671

  5. Moving Object Detection Using Scanning Camera on a High-Precision Intelligent Holder

    Directory of Open Access Journals (Sweden)

    Shuoyang Chen

    2016-10-01

    Full Text Available During the process of moving object detection in an intelligent visual surveillance system, a scenario with complex background is sure to appear. The traditional methods, such as “frame difference” and “optical flow”, may not able to deal with the problem very well. In such scenarios, we use a modified algorithm to do the background modeling work. In this paper, we use edge detection to get an edge difference image just to enhance the ability of resistance illumination variation. Then we use a “multi-block temporal-analyzing LBP (Local Binary Pattern” algorithm to do the segmentation. In the end, a connected component is used to locate the object. We also produce a hardware platform, the core of which consists of the DSP (Digital Signal Processor and FPGA (Field Programmable Gate Array platforms and the high-precision intelligent holder.

  6. Application of bias correction methods to improve U{sub 3}Si{sub 2} sample preparation for quantitative analysis by WDXRF

    Energy Technology Data Exchange (ETDEWEB)

    Scapin, Marcos A.; Guilhen, Sabine N.; Azevedo, Luciana C. de; Cotrim, Marycel E.B.; Pires, Maria Ap. F., E-mail: mascapin@ipen.br, E-mail: snguilhen@ipen.br, E-mail: lvsantana@ipen.br, E-mail: mecotrim@ipen.br, E-mail: mapires@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The determination of silicon (Si), total uranium (U) and impurities in uranium-silicide (U{sub 3}Si{sub 2}) samples by wavelength dispersion X-ray fluorescence technique (WDXRF) has been already validated and is currently implemented at IPEN's X-Ray Fluorescence Laboratory (IPEN-CNEN/SP) in São Paulo, Brazil. Sample preparation requires the use of approximately 3 g of H{sub 3}BO{sub 3} as sample holder and 1.8 g of U{sub 3}Si{sub 2}. However, because boron is a neutron absorber, this procedure precludes U{sub 3}Si{sub 2} sample's recovery, which, in time, considering routinely analysis, may account for significant unusable uranium waste. An estimated average of 15 samples per month are expected to be analyzed by WDXRF, resulting in approx. 320 g of U{sub 3}Si{sub 2} that would not return to the nuclear fuel cycle. This not only impacts in production losses, but generates another problem: radioactive waste management. The purpose of this paper is to present the mathematical models that may be applied for the correction of systematic errors when H{sub 3}BO{sub 3} sample holder is substituted by cellulose-acetate {[C_6H_7O_2(OH)_3_-_m(OOCCH_3)m], m = 0∼3}, thus enabling U{sub 3}Si{sub 2} sample’s recovery. The results demonstrate that the adopted mathematical model is statistically satisfactory, allowing the optimization of the procedure. (author)

  7. The Market for Ph.D. Holders in Greece: Probit and Multinomial Logit Analysis of their Employment Status

    OpenAIRE

    Joan Daouli; Eirini Konstantina Nikolatou

    2015-01-01

    The objective of this paper is to investigate the factors influencing the probability that a Ph.D. holder in Greece will work in the academic sector, as well as the probability of his or her choosing employment in various sectors of industry and occupational categories. Probit/multinomial logit models are employed using the 2001 Census data. The empirical results indicate that being young, married, having a Ph.D. in Natural Sciences and/or in Engineering, granted by a Greek university, increa...

  8. Data analysis of a polycrystalline nickel sample obtained with neutron diffraction

    International Nuclear Information System (INIS)

    Parente, C.B.R.; Mazzochi, V.L.; Araujo Kaschny, J.R. de; Costa, M.S. da; Rizzo, P.; Campos, W.M.S.

    1990-01-01

    A simple analysis of the nickel structure was made. Neutron diffraction data were used, obtained with polycrystalline nickel placed in a cylindrical sample-holder with dimensions of 1,5cm of diameter and 5cm of height. The theoretical intensities were calculated of 3 forms: 1. without considering the temperature and obsorption effects, 2. considering only the temperature effect and 3. considering both the temperature and absorption effects. The disagreement factors found in this 3 cases were, respectively, R 1 = 13.4%, R 2 = 7,7% e R 3 = 7,5%. (L.C.)

  9. Evaluation algorithm for Hp (10), Hp (0.07) and response matrix in mixed fields of 137Cs+90Sr/90Y for badge TLD without use of its commercial holder

    International Nuclear Information System (INIS)

    Alvarez R, Jose T.; Tovar M, Victor M.; Castaneda P, Mario; Padilla, Ismael

    2008-01-01

    American standards HPS N 13.11 (1993, 2001) set up performance category tests for deep and shallow personal equivalent dose evaluated by dosimetry processors. These standards establish the parameters bias B, standard deviation S and tolerance level L, whose values indicate the deviations from the conventionally true value for the equivalent dose. On the other hand, for a right evaluation of the equivalent dose, all personal dosimetry systems have four basic components: badge, holder, reading protocol and dose evaluation algorithm. However, in Nuclear Plant Laguna Verde NPP dosimetry laboratory uses the badges Panasonic 802 A without Panasonic UD874AT holder, and instead employs a polyethylene holder bag to protect the badge from misuse. This situation disables the manufacturer algorithm designed for the combination: badge + holder. Therefore, the purpose of this work is to design a personal equivalent dose algorithm for this badge + bag, such this corrected algorithm let fulfill the HPS N 13.11 (1993) categories II, IV, V and VII. The algorithm starts from the readings of the elements: E1, E2, E3 and E4, only corrected by their element correction factor ECF. Additionally, we characterize the badge + bag by means of the response function for: 137 Cs, 85 Kr and 90 Sr/ 90 Y radiation fields. Finally, for validation of the algorithm one verifies that parameters B, S and L accomplish with the limits indicated by the standard. (author)

  10. A ‘smart’ tube holder enables real-time sample monitoring in a standard lab centrifuge

    Science.gov (United States)

    Hoang, Tony; Moskwa, Nicholas

    2018-01-01

    The centrifuge is among the oldest and most widely used pieces of laboratory equipment, with significant applications that include clinical diagnostics and biomedical research. A major limitation of laboratory centrifuges is their “black box” nature, limiting sample observation to before and after centrifugation. Thus, optimized protocols require significant trial and error, while unoptimized protocols waste time by centrifuging longer than necessary or material due to incomplete sedimentation. Here, we developed an instrumented centrifuge tube receptacle compatible with several commercial benchtop centrifuges that can provide real-time sample analysis during centrifugation. We demonstrated the system by monitoring cell separations during centrifugation for different spin speeds, concentrations, buffers, cell types, and temperatures. We show that the collected data are valuable for analytical purposes (e.g. quality control), or as feedback to the user or the instrument. For the latter, we verified an adaptation where complete sedimentation turned off the centrifuge and notified the user by a text message. Our system adds new functionality to existing laboratory centrifuges, saving users time and providing useful feedback. This add-on potentially enables new analytical applications for an instrument that has remained largely unchanged for decades. PMID:29659624

  11. Indigenous development of automated metallographic sample preparation system

    International Nuclear Information System (INIS)

    Kulkarni, A.P.; Pandit, K.M.; Deshmukh, A.G.; Sahoo, K.C.

    2005-01-01

    Surface preparation of specimens for Metallographic studies on irradiated material involves a lot of remote handling of radioactive material by skilled manpower. These are laborious and man-rem intensive activities and put limitations on number of samples that can be prepared for the metallographic studies. To overcome these limitations, automated systems have been developed for surface preparation of specimens in PIE division. The system includes (i) Grinding and polishing stations (ii) Water jet cleaning station (iii) Ultrasonic cleaning stations (iv) Drying station (v) Sample loading and unloading station (vi) Dispenser for slurries and diluents and (vii) Automated head for movement of the sample holder disc from one station to other. System facilities the operator for programming/changing sequence of the sample preparations including remote changing of grinding/polishing discs from the stations. Two such systems have been installed and commissioned in Hot Cell for PIE Division. These are being used for preparation of irradiated samples from nuclear fuels and structural components. This development has increased the throughput of metallography work and savings in terms of (man-severts) radiation exposure to operators. This presentation will provide details of the challenges in undertaking this developmental work. (author)

  12. Free at Last: Rejecting Equal Sovereignty and Restoring the Constitutional Right to Vote: Shelby County v. Holder

    OpenAIRE

    Guinier, C. Lani; Blacksher, James

    2014-01-01

    The "equal sovereignty" principle the Supreme Court majority relied on in Shelby County v. Holder to strike down the coverage formula in Section 4 of the Voting Rights Act is rooted in the jurisprudence of slavery. In the infamous 1857 case of Dred Scott v. Sandford, Chief Justice Roger Taney held that black Americans, slave or free, were not members of the sovereign people and could never be "citizens" within the meaning of the Constitution. Otherwise, he said, blacks would be entitled to al...

  13. Monosyllabic Place Holders in Child Acquisition of Spanish as a Second Language

    Directory of Open Access Journals (Sweden)

    Estrella Nicolás

    2018-03-01

    Full Text Available Monosyllabic place holders (MPHs have been studied extensively in first-language (L1 acquisition of Spanish and other Romance languages. However, the study of MPHs in second-language (L2 acquisition, both by children and adults, has received much less attention. This study provides evidence for the presence of MPHs in the L2 Spanish of two L1 Moroccan Arabic children living in Spain. The age difference between the children (10;9 for Rachida and 6;10 for Khalid allows us to address the issue of whether the younger child would use MPHs, as is the case in L1 acquisition. However, what the data show is that both children used MPHs, although Khalid’s MPH rate was slightly higher than Rachida’s. Therefore, based on these findings we argue that MPHs can constitute a strategy available for all child learners of Spanish.

  14. Feasibility of scaffold production using Ti-13Nb-13Zr alloy and naphthalene as space holder

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Persio Mozart; Komorizono, Amanda Akemy; Antonini, Leonardo; Rodrigues Junior, Durval, E-mail: persiomozart@usp.br [Universidade de Sao Paulo (USP), Lorena, SP (Brazil). Escola de Engenharia

    2016-07-01

    Full text: The tissue engineering has as goal the repairing of bone defects, usually using a synthetic structure with pores in three dimensions, named scaffold. The structure of the scaffolds present interconnected pores, with controlled porosity, according to the process used to produce the scaffold. The present work has as main objective the processing of the Ti-13Nb-13Zr alloy (percentages in weight) using the powder metallurgy technique named space-holder, to obtain porous scaffolds for osseointegration. Firstly, elementary powders of Ti, Nb, and Zr were weighted to obtain the composition 74wt.%Ti+13wt.%Nb+13wt.%Zr, such that 3.5g was direct mixed with naphthalene, named 'control' condition, and 3.5g was milled in a SPEX mill for 8h (sample MA8h), using grinding midia of tungsten carbide and isopropyl alcohol as process controlling agent. Both powders, in 'control' and MA8h conditions, were mixed with naphthalene powder (50% in volume and particle size in the range from 500μm to 1mm) for 30 minutes. The powders mixed with naftalen were pressed to obtain green bodies and sintered at 1000°C for 1h in vacuum better than 5 x 10{sup -5} mbar. The sintered samples were characterized using XRD, He picnometry, optical microscopy, SEM-EDX, and microhardness test. From the XRD results, it could be found the presence of titanium α and β phases, also present in the SEM-EDX analyses. The SEM analyses also showed, in the samples, the presence of widmantäten microstructure and a structure of pores, with size in the range from 300μm to 1mm. The observed pores were also interconnected and were connected to the surface. From the results of He picnometry and microscopy, it could be observed that the samples presented porosity in the range from 30% to 50% in volume. It could be concluded that it is possible to obtain scaffolds of the Ti-13Nb-13Zr alloy using the techniques developed in the present work. (author)

  15. Is a 10-sow unit economically sustainable? A profitability assessment of productivity amongst small-holder pig farmers, Mpumalanga, South Africa.

    Science.gov (United States)

    Munzhelele, Priscilla; Oguttu, James W; Fasina, Folorunso O

    2016-05-12

    The majority of small-holder pig farmers in Mpumalanga had between 1- and 10-sow herds. The main aim of this study is to evaluate the current government agricultural intervention (supply of 10 sows and a boar) in terms of technical and economic feasibilities and ascertain whether the small-scale pig value chain system alleviates poverty. Data were obtained from 220 randomly selected small-holder pig farmers using a semi-structured questionnaire. The results showed that 58% farrowed ≤ 10 piglets/born/sow/litter, 44.2% practiced no weaning method and many fed swill and leftovers alone (41.6%). Pair-wise association revealed that the feeding of commercial feeds had a relationship with pigs in relatively good to very good body condition. Pigs in poor body condition were positively correlated with the feeding of swill alone. The economic models for the 10-sow unit proved that pig farming is unprofitable if the current management and feeding systems that operate in the commercial industry are utilised. However, only through a combination of cooperative systems, benefits of economies of scale, reduction of preweaning mortalities and structured government inputs can pig production be profitable at this scale of production.

  16. The effect of alumina particles on the microstructural and mechanical properties of copper foams fabricated by space-holder method

    Science.gov (United States)

    Salvo, C.; Aguilar, C.; Lascano, S.; Pérez, L.; López, M.; Mangalaraja, R. V.

    2018-05-01

    The copper foam is an interesting field of research because of its several advantages as an engineering material. Powder metallurgy presents an alternative route to obtain a porous structure with high strength to weight ratio and functional properties. The viability of processing copper foam separately with two different space-holders such as ammonium hydrogen carbonate (NH4HCO3) and sodium chloride (NaCl) of 50 vol% was studied. The green compacts obtained under 200 MPa were sintered at different cycles for the complete removal of space-holder. The sintered foams were characterized by optical microscopy (OM), scanning electron microscopy (SEM) and uniaxial testing machine (UTM) to study their structural features and compressive strength, respectively. The results showed that NaCl particles were the best alternative to obtain a porous structure, hence two different sizes (1 and 0.01 μm) of alumina (Al2O3) particles with 2, 4 and 6 vol% were used to fabricate copper foams. As a result, a bimodal structure consisting of macro and micropores with a highly interconnected porosity was achieved. In addition, the smaller size alumina particles promoted a higher density of pores, however, the compressive strength was reduced for the higher volume fraction of alumina particles.

  17. Analysis of the sensitivity and sample-furnace thermal-lag of a differential thermal analyzer

    International Nuclear Information System (INIS)

    Roura, P.; Farjas, J.

    2005-01-01

    The heat exchange between the horizontal furnace of a differential thermal analyzer (DTA) and the sample is analyzed with the aim of understanding the parameters governing the thermal signal. The resistance due to radiation and conduction through the gas has been calculated and compared to the experimental values of the thermal-lag between the sample and furnace and apparatus sensitivity. The overall evolution of these parameters with the temperature and their relative values are well understood by considering the temperature differences that arise between the sample and holder. Two RC thermal models are used for describing the apparatus performance at different temperature ranges. Finally, the possibility of improving the signal quality through the control of the leak resistances is stressed

  18. A New Cryogenic Sample Manipulator For SRC's Scienta 2002 System

    International Nuclear Information System (INIS)

    Gundelach, Chad T.; Fisher, Mike V.; Hoechst, Hartmut

    2004-01-01

    We discuss the first bench tests of a sample manipulator which was recently designed at SRC for the Scienta 2002 User system. The manipulator concept utilizes the 10 deg. angular window of the Scienta in the horizontal plane (angle dispersion) by rotating the sample normal around the vertical axis while angular scans along the vertical axis (energy dispersion) are continuous within ±30 deg. relative to the electron lens by rotating the sample around the horizontal axis. With this concept it is possible to precisely map the entire two-dimensional k-space of a crystal by means of stitching together 10 deg. wide stripes centered +15 deg. to -50 deg. relative to the sample normal. Three degrees of translational freedom allow positioning the sample surface at the focal point of the analyzer. Two degrees of rotational freedom are available at this position for manipulating the sample. Samples are mounted to a standard holder and transferred to the manipulator via a load-lock system attached to a prep chamber. The manipulator is configured with a cryogenic cold head, an electrical heater, and a temperature sensor permitting continuous closed-loop operation for 20-380 K

  19. TESTING OF THE OSCILLATIONS DAMPING CAPABILITY BY EXTERNAL TURNING WITH THE USE OF ALTERNATE BARS IN THE CONSTRUCTION OF THE TURNING TOOL HOLDER

    Directory of Open Access Journals (Sweden)

    Marten Madissoo

    2015-09-01

    Full Text Available Modern machinery is highly demanding and the requirement for producing high quality parts is crucial in modern engineering. The most important is the setting of dimensions and tolerances of the surfaces which work together. The shape- and position tolerances may raise the existence of failures and can affect the performance of different machinery. Consequently it is very important that the cutting process is as stable as possible in order to get the best quality parts and to achieve the maximum lifetime of the cutting tool. Unfortunately the machining of complex products from hard materials is accompanied by loss of stability of the cutting process, which leads to tool oscillations, causing an increasing wear of the cutting tools, reducing the lifetime of the machine actuators, which ultimately affects the quality and accuracy of processing responsible products. To avoid this kind of chatter vibrations it is possible to construct specialized cutting tools and tool holder witch reduce this kind of vibrations and can help to increase the manufacturing precision of machine components. In consequence of this the paper focuses on testing the utility effect of a cutting tool holder with alternate bars of different material structure in its construction. The different bars are made from rolled steel and have an anisotropic structure which also has different mechanical properties. This construction is considered as a method to improve the cutting stability of the cutting tool and helps to reduce the oscillations in the finishing turning. The method for the construction of the damper instrument holder with alternate bars is proposed.DOI: http://dx.doi.org/10.5755/j01.ms.21.3.7351

  20. 17 CFR 270.18f-2 - Fair and equitable treatment for holders of each class or series of stock of series investment...

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Fair and equitable treatment for holders of each class or series of stock of series investment companies. 270.18f-2 Section 270.18f... or series of stock of series investment companies. (a) For purposes of this § 270.18f-2 a series...

  1. Characterization of YBaCuO films deposited by the sputtering method using a temple-bell-type substrate holder

    International Nuclear Information System (INIS)

    Kajikawa, H.; Fukumoto, Y.; Shibutani, K.; Hayashi, S.; Ishibashi, K.; Inoue, K.

    1992-01-01

    The as-grown YBaCuO films deposited by the off-axis sputtering method using a temple-bell type substrate holder showed a good crystalline quality with a minimum yield value x min of 0.9 MeV He ions of 3.8%. The post-annealing degraded the crystalline quality to increase x min up to 11.8%, though it improved both the T c and J c . It was supposed that the degradation was caused by the re-arrangement of oxygen atoms. (orig.)

  2. The Motivation and Identity Challenges for PhD Holders in the Transition to Science and Mathematics Teaching in Secondary Education: A Pilot Study

    Science.gov (United States)

    Whannell, Robert; Allen, Bill

    2014-01-01

    Australian secondary education has endured a chronic shortage of qualified mathematics and science teachers for a number of years, particularly in rural and remote areas. A longitudinal research project examining the capacity for the holders of PhD level qualifications in mathematics and science to be utilised as one means of addressing this…

  3. Is a 10-sow unit economically sustainable? A profitability assessment of productivity amongst small-holder pig farmers, Mpumalanga, South Africa

    Directory of Open Access Journals (Sweden)

    Priscilla Munzhelele

    2016-05-01

    Full Text Available The majority of small-holder pig farmers in Mpumalanga had between 1- and 10-sow herds. The main aim of this study is to evaluate the current government agricultural intervention (supply of 10 sows and a boar in terms of technical and economic feasibilities and ascertain whether the small-scale pig value chain system alleviates poverty. Data were obtained from 220 randomly selected small-holder pig farmers using a semi-structured questionnaire. The results showed that 58% farrowed ≤ 10 piglets/born/sow/litter, 44.2% practiced no weaning method and many fed swill and leftovers alone (41.6%. Pair-wise association revealed that the feeding of commercial feeds had a relationship with pigs in relatively good to very good body condition. Pigs in poor body condition were positively correlated with the feeding of swill alone. The economic models for the 10-sow unit proved that pig farming is unprofitable if the current management and feeding systems that operate in the commercial industry are utilised. However, only through a combination of cooperative systems, benefits of economies of scale, reduction of preweaning mortalities and structured government inputs can pig production be profitable at this scale of production. Keywords: piglets; market; profit; economics; feeds

  4. Experimental set-up for electrical resistivity measurements at low temperature in amorphous and crystalline metallic samples

    International Nuclear Information System (INIS)

    Rodriquez Fernandez, J.M.; Lopez Sanchez, R.J.; Gomez-Sal, J.C.

    1986-01-01

    The experimental set-up to measure the thermal variation of the electrical resistivity between 10.5 K and 300 K, has been developed. A four probe A.C. method with a synchronous-detection (lock'in) technique were the idoneous for our proposes. We have designed a new type of pressure sample-holder adopted to the CS-202 type cryostat. The measurements performed on samples already known have allowed us to determine the sensitivity of our experiments, which is Δ ρ/ρ=2x10 -4 . The measurements performed in the new Y 3 Rh 2 Si 2 compound which at 10 K has no magnetic ordering, are also presented. (author)

  5. Holder continuity of bounded weak solutions to generalized parabolic p-Laplacian equations II: singular case

    Directory of Open Access Journals (Sweden)

    Sukjung Hwang

    2015-11-01

    Full Text Available Here we generalize quasilinear parabolic p-Laplacian type equations to obtain the prototype equation $$ u_t - \\hbox{div} \\Big(\\frac{g(|Du|}{|Du|} Du\\Big = 0, $$ where g is a nonnegative, increasing, and continuous function trapped in between two power functions $|Du|^{g_0 -1}$ and $|Du|^{g_1 -1}$ with $1Holder continuous with some degree of commonality between degenerate and singular types. By using geometric characters, our proof does not rely on any of alternatives which is based on the size of solutions.

  6. Improvement of detection limits in the annular 241Am radioisotope-excited X-ray fluorescence analysis for minor elements of environmental sample

    International Nuclear Information System (INIS)

    Thai My Phe; Ngo Quang Huy; Nguyen Van Suc; Tran Van Luyen; Nguyen Van Mai; Dao Van Hoang; Trinh Thi Bich

    2003-01-01

    The improvement of limit detection to elements Pb, Sr, Zr, Nd, and Ba in mud samples is presented. Two ways for reducing background radiation are: 1/ choosing the optimum γ-ray-excited X-ray assembly such as scattering angle (θ), filter for primary beam, excited holder, collimator for fluorescent lines, etc; 2/ using the chemical separation method to remove major composition for matrix reduction. (NHA)

  7. Systems and methods for large-scale nanotemplate and nanowire fabrication

    KAUST Repository

    Vidal, Enrique Vilanova

    2016-03-31

    Systems and methods for largescale nanotemplate and nanowire fabrication are provided. The system can include a sample holder and one or more chemical containers fluidly connected to the sample holder. The sample holder can be configured to contain a solution and to releasably hold a substrate material within the solution. In other aspects, the system can include a robotic arm including a head configured to releasably hold a substrate material. The methods can include initiating a treatment step by moving a chemical solution from a chemical container to the sample holder to submerge the substrate material for a period of time. The methods can include moving the robotic arm to position the substrate in a chemical container. The treatment steps can be stopped by removing the chemical solution from the sample holder or by moving the robotic arm to remove the substrate from the chemical container. The treatment steps can include degreasing, polishing, rinsing, anodization, and deposition.

  8. Dose assessment for CEGB users of the Kodak type 2 film used in the NRPB/AERE holder

    International Nuclear Information System (INIS)

    Hill, M.J.

    1980-07-01

    Some work, complementary to that of the National Radiological Protection Board (NRPB) and the Atomic Energy Research Establishment (AERE), has been done at Berkeley Nuclear Laboratories (BNL) on the response of the Kodak Type 2 film in the NRPB/AERE holder. Initial results indicate that the combination forms a satisfactory dosemeter. Comparison between the BNL and NRPB results shows differences which appear to be due to the fact that the angle of incidence was 90 0 for the former and 35 0 for the latter. Some conclusions are drawn on dosimetry but in general, for CEGB users, no substantial changes from existing procedures are required. (author)

  9. The Effect of Holder Pasteurization on Nutrients and Biologically-Active Components in Donor Human Milk: A Review.

    Science.gov (United States)

    Peila, Chiara; Moro, Guido E; Bertino, Enrico; Cavallarin, Laura; Giribaldi, Marzia; Giuliani, Francesca; Cresi, Francesco; Coscia, Alessandra

    2016-08-02

    When a mother's milk is unavailable, the best alternative is donor milk (DM). Milk delivered to Human Milk Banks should be pasteurized in order to inactivate the microbial agents that may be present. Currently, pasteurization, performed at 62.5 °C for 30 min (Holder Pasteurization, HoP), is recommended for this purpose in international guidelines. Several studies have been performed to investigate the effects of HoP on the properties of DM. The present paper has the aim of reviewing the published papers on this topic, and to provide a comparison of the reported variations of biologically-active DM components before and after HoP. This review was performed by searching the MEDLINE, EMBASE, CINHAL and Cochrane Library databases. Studies that clearly identified the HoP parameters and compared the same DM samples, before and after pasteurization, were focused on. A total of 44 articles satisfied the above criteria, and were therefore selected. The findings from the literature report variable results. A possible explanation for this may be the heterogeneity of the test protocols that were applied. Moreover, the present review spans more than five decades, and modern pasteurizers may be able to modify the degradation kinetics for heat-sensitive substances, compared to older ones. Overall, the data indicate that HoP affects several milk components, although it is difficult to quantify the degradation degree. However, clinical practices demonstrate that many beneficial properties of DM still persist after HoP.

  10. A novel feedback control system – Controlling the material flow in deep drawing using distributed blank-holder force

    DEFF Research Database (Denmark)

    Endelt, Benny Ørtoft; Tommerup, Søren; Danckert, Joachim

    2013-01-01

    The performance of a feedback control system is often limited by the quality of the model on which it is based, and often the controller design is based on trial and error due to insufficient modeling capabilities. A framework is proposed where the controller design is based on classical state...... on a deep drawing operation where the objective was to control material flow throughout the part using only spatial information regarding flange draw-in. The control system controls both the magnitude and distribution of the blank-holder force. The methodology proved stable and flexible with respect...

  11. Who Will Do Science? Trends, and Their Causes in Minority and Female Representation among Holders of Advanced Degrees in Science and Mathematics. A Special Report.

    Science.gov (United States)

    Berryman, Sue E.

    This paper describes trends in and causes of minority and female representation among holders of advanced science and math degrees. The minority groups studied are Blacks, Hispanic Americans, American Indians, and Asian Americans, all of whom are compared with Whites. The degrees looked at include those in math, the computer sciences, physical…

  12. In-situ transmission electron microscopy of the solid-phase epitaxial growth of GaAs: sample preparation and artifact characterization

    International Nuclear Information System (INIS)

    Llewellyn, D.J.; Llewellyn, D.J.; Belay, K.B.; Ridgway, M.C.

    1998-01-01

    In-situ transmission electron microscopy (TEM) has been used to characterize the solid phase epitaxial growth of amorphized GaAs at a temperature of 260 deg C. To maximize heat transfer from the heated holder to the sample and minimize electron-irradiation induced artifacts, non-conventional methodologies were utilized for the preparation of cross-sectional samples. GaAs 3x1 mm rectangular wafers were cleaved then glued face-to-face to form a wafer stack size of 3x3 mm while maintaining the TEM region at the center. This stack was subsequently polished on the cross-section to a thickness of ∼ 200 μm. A 3 mm disc was then cut perpendicular to the cross-section using a Gatan ultrasonic cutter. The disc was polished then dimpled on both sides to a thickness of ∼ 15 μm. This was ion-beam milled at liquid nitrogen temperature to an electron-transparent layer. From a comparison of in-situ and ex-situ measurements of the recrystallization rate, the actual sample temperature during in-situ characterization was estimated to deviate by ≤ 20 deg C from that of the heated holder. The influence of electron-irradiation was found to be negligible by comparing the recrystallization rate and microstructure of irradiated and unirradiated regions of comparable thickness. Similarly, the influence of the 'thin-foil effect' was found to be negligible by comparing the recrystallization rate and microstructure of thick and thin regions, the former determined after the removal of the sample from the microscope and further ion-beam milling of tens of microns of material. In conclusion, the potential influence of artifacts during in-situ TEM can be minimized by the appropriate choice of sample preparation procedures. (authors)

  13. Improving the productivity of imported dairy cattle on small-holder farms in Morocco through supplementation with fish silage blocks

    International Nuclear Information System (INIS)

    Guerouali, A.

    1999-01-01

    The present study was designed to identify problems that lower the productivity of imported dairy cattle in Morocco. For this purpose, a comprehensive survey was carried out on 8 small-holder farms over a period of two years. Analysis of the data collected indicated that in most of the herds reproductive performance was adequate (calving intervals ranging from 338 ± 11 to 420 ± 31 and services to conception ranging from 1.14 ± 0.13 to 1.91 ± 0.3), but the animals had difficulty in meeting the nutrient requirements for milk production. Although some farmers provided supplements to their animals they were either expensive or not available at the required time. One possible way of alleviating the problem was the introduction of a fish by-product into the dairy cattle ration. Two experiments were conducted, one at the Institute experimental farm and the other at a private farm selected for the survey. In both experiments, fish silage blocks were incorporated into the ration of dairy cattle in replacement of an equal amount of the most commonly used supplements. The introduction of fish silage blocks in the ration did not affect their intake or body condition. In addition, the yield and quality of the milk were maintained. This substitution allowed the farmer to utilize by-products from the fish industry which are readily available and less costly than most conventional supplementary feeds. It is concluded, that the proposed utilization of fish silage blocks will reduce the production costs and improve the economic efficiency of the small-holder farms. (author)

  14. Measured Thermal and Fast Neutron Fluence Rates for ATF-1 Holders During ATR Cycle 157D

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 157D which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution.

  15. Sampling technique for collection of expired COsub(2) in studies using naturally labelled sup(13)C in calves

    International Nuclear Information System (INIS)

    Chevalier, R.; Pelletier, G.; Gagnon, M.

    1984-01-01

    Natural isotopic labelling of animal metabolic processes presents great advantages over the use of artificially enriched compounds. These advantages include the use of natural diets, low cost and easiness of handling, sampling and disposal. Changes in the sup(13)C/sup(12)C ratio of expired COsub(2) after ingestion of a test meal containing a variable proportion of Csub(3) and/or Csub(4) plant-derived products permits measurements of the immediate oxidation of dietary carbohydrates. A breathing device for collection of expired COsub(2) and purification techniques are described. The breath-sampling device is composed of a polypropylene enclosure and a rubber bag. The rubber bag is blown up by the animal and a sample of the expired gas is transferred to a sampling glass holder in which a vacuum had been previously achieved. Sample purification of expired COsub(2) is done by differential freezing

  16. Solo Intracorporeal Esophagojejunostomy Reconstruction Using a Laparoscopic Scope Holder in Single-Port Laparoscopic Total Gastrectomy for Early Gastric Cancer.

    Science.gov (United States)

    Ahn, Sang-Hoon; Son, Sang-Yong; Jung, Do Hyun; Park, Young Suk; Shin, Dong Joon; Park, Do Joong; Kim, Hyung-Ho

    2015-06-01

    Single-incision laparoscopic total gastrectomy for gastric cancer has recently been reported by Seoul National University Bundang Hospital. However, this is not a popular procedure primarily because of the technical difficulties involved in achieving consistent intracorporeal esophagojejunostomy. At Seoul National University Bundang Hospital, we recently introduced a simple, easy-to-use, low-profile laparoscopic manual scope holder that enables the maintenance of a stable field of view, the most demanding condition in single-port gastrectomy. In this technical report, we describe in detail the world's first solo single-incision laparoscopic total gastrectomy with D1+ lymph node dissection and intracorporeal esophagojejunostomy for proximal early gastric cancer.

  17. Electron emission of cathode holder of vacuum diode of an intense electron-beam accelerator and its effect on the output voltage

    OpenAIRE

    Xin-Bing Cheng; Jin-Liang Liu; Hong-Bo Zhang; Zhi-Qiang Hong; Bao-Liang Qian

    2011-01-01

    The vacuum diode which is used to generate relativistic electron beams is one of the most important parts of a pulsed-power modulator. In this paper, the electron emission of cathode holder of a vacuum diode and its effect on the output voltage is investigated by experiments on an intense electron-beam accelerator with 180 ns full width at half maximum and 200–500 kV output voltage. First, the field emission is analyzed and the electric field of the vacuum chamber is calculated. Then, the fla...

  18. Sampling polyhexamethylene guanidine aerosols using eosin Y-coated glass beads

    International Nuclear Information System (INIS)

    Choi, Sang Hyun; Park, Seon Kyung; Kang, Hyun Joong; Kwon, Jung Hwan; Lee, Kyu Hong

    2015-01-01

    Fatalities caused by the use of polyhexamethylene guanidine (PHMG), a general-purpose chemical germicide used as a humidifier disinfectant in Korea, have raised concerns about exposure to biocide aerosols in indoor environments. A sampler capable of accumulating PHMG from aqueous aerosols was developed as an alternative to low-volume air samplers. This sampler was prepared by placing glass beads coated with 2-(2,4,5,7-tetrabromo-6-oxido-3-oxo-3H-xanthen-9-yl)benzoate (Eosin Y) in a custom-made plastic holder. Passive sampling rates, measured in a bench-top exposure chamber at two different aqueous PHMG aerosol generation rates, were found to be independent of the experimental conditions. This suggests that the capacity of the sampler to accumulate the PHMG aerosol was sufficient for the sampling duration tested. However, the passive sampling rate was 7.6 × 10"−"6 m"3/h for the sampler area of 22 cm"2. This rate is lower than the typical human breathing rate and inadequate for quantitative instrumental analyses at low concentrations in indoor air. A 30-fold enhancement of the sampling rate was achieved by forced convection using a commercial battery-operated fan at ≥2000 rpm. With this accelerated sampling rate, the sampler could be used to monitor time-integrated concentrations of PHMG aerosols in the air

  19. Sampling polyhexamethylene guanidine aerosols using eosin Y-coated glass beads

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sang Hyun; Park, Seon Kyung; Kang, Hyun Joong; Kwon, Jung Hwan [Korea University, Seoul (Korea, Republic of); Lee, Kyu Hong [Korea Institute of Toxicology, Jeongeup (Korea, Republic of)

    2015-07-15

    Fatalities caused by the use of polyhexamethylene guanidine (PHMG), a general-purpose chemical germicide used as a humidifier disinfectant in Korea, have raised concerns about exposure to biocide aerosols in indoor environments. A sampler capable of accumulating PHMG from aqueous aerosols was developed as an alternative to low-volume air samplers. This sampler was prepared by placing glass beads coated with 2-(2,4,5,7-tetrabromo-6-oxido-3-oxo-3H-xanthen-9-yl)benzoate (Eosin Y) in a custom-made plastic holder. Passive sampling rates, measured in a bench-top exposure chamber at two different aqueous PHMG aerosol generation rates, were found to be independent of the experimental conditions. This suggests that the capacity of the sampler to accumulate the PHMG aerosol was sufficient for the sampling duration tested. However, the passive sampling rate was 7.6 × 10{sup −6} m{sup 3}/h for the sampler area of 22 cm{sup 2}. This rate is lower than the typical human breathing rate and inadequate for quantitative instrumental analyses at low concentrations in indoor air. A 30-fold enhancement of the sampling rate was achieved by forced convection using a commercial battery-operated fan at ≥2000 rpm. With this accelerated sampling rate, the sampler could be used to monitor time-integrated concentrations of PHMG aerosols in the air.

  20. Activation of TRIGA Mark II research reactor concrete shield

    International Nuclear Information System (INIS)

    Zagar, Tomaz; Ravnik, Matjaz; Bozic, Matjaz

    2002-01-01

    To determine neutron activation inside the TRIGA research reactor concrete body a special sample-holder for irradiation inside horizontal channel was developed and tested. In the sample-holder various samples can be irradiated at different concrete shielding depths. In this paper the description of the sample-holder, experiment conditions and results of long-lived activation measurements are given. Long-lived neutron-induced gamma-ray-emitting radioactive nuclides in the samples were measured with HPGe detector. The most active long-lived radioactive nuclides in ordinary concrete samples were found to be 60 Co and 152 Eu and in barytes concrete samples 60 Co, 152 Eu and 133 Ba. Measured activity density of all nuclides was found to decrease almost linearly with depth in logarithmic scale. (author)

  1. Elemental distribution and sample integrity comparison of freeze-dried and frozen-hydrated biological tissue samples with nuclear microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Vavpetič, P., E-mail: primoz.vavpetic@ijs.si [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Vogel-Mikuš, K. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Jeromel, L. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); Ogrinc Potočnik, N. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia); FOM-Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands); Pongrac, P. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Department of Plant Physiology, University of Bayreuth, Universitätstr. 30, 95447 Bayreuth (Germany); Drobne, D.; Pipan Tkalec, Ž.; Novak, S.; Kos, M.; Koren, Š.; Regvar, M. [Biotechnical Faculty, Department of Biology, University of Ljubljana, Jamnikarjeva 101, SI-1000 Ljubljana (Slovenia); Pelicon, P. [Jožef Stefan Institute, Jamova 39, SI-1000 Ljubljana (Slovenia)

    2015-04-01

    The analysis of biological samples in frozen-hydrated state with micro-PIXE technique at Jožef Stefan Institute (JSI) nuclear microprobe has matured to a point that enables us to measure and examine frozen tissue samples routinely as a standard research method. Cryotome-cut slice of frozen-hydrated biological sample is mounted between two thin foils and positioned on the sample holder. The temperature of the cold stage in the measuring chamber is kept below 130 K throughout the insertion of the samples and the proton beam exposure. Matrix composition of frozen-hydrated tissue is consisted mostly of ice. Sample deterioration during proton beam exposure is monitored during the experiment, as both Elastic Backscattering Spectrometry (EBS) and Scanning Transmission Ion Microscopy (STIM) in on–off axis geometry are recorded together with the events in two PIXE detectors and backscattered ions from the chopper in a single list-mode file. The aim of this experiment was to determine differences and similarities between two kinds of biological sample preparation techniques for micro-PIXE analysis, namely freeze-drying and frozen-hydrated sample preparation in order to evaluate the improvements in the elemental localisation of the latter technique if any. In the presented work, a standard micro-PIXE configuration for tissue mapping at JSI was used with five detection systems operating in parallel, with proton beam cross section of 1.0 × 1.0 μm{sup 2} and a beam current of 100 pA. The comparison of the resulting elemental distributions measured at the biological tissue prepared in the frozen-hydrated and in the freeze-dried state revealed differences in elemental distribution of particular elements at the cellular level due to the morphology alteration in particular tissue compartments induced either by water removal in the lyophilisation process or by unsatisfactory preparation of samples for cutting and mounting during the shock-freezing phase of sample preparation.

  2. A Simple Refining Technique of Coconut Oil for Small Holder Industries

    Directory of Open Access Journals (Sweden)

    Sugeng Triyono

    2009-04-01

    Full Text Available A simple refining equipment and process for small holder industries of edible coconut oil has beeninvestigated. The equipment consisted of 20-L filtering and NaOH neutralization bottles. Filtration wasintended to remove impurities such as gums and pigment, while neutralization was to remove free fattyacids (FFA and other non-fat materials. In the experiment, the crude coconut oil was found to have impurityof 0.16%, FFA of 8.02%, saponification number of 270, and water content of 0.33%. The results showed thateither granular activated carbon (GAC or zeolite filtration can be chosen individually to remove physicalimpurity. The GAC or zeolite-filtered coconut oil contained impurity less than the SNI standard of 0.05%.In term of FFA; however, the NaOH neutralized coconut oil did not meet the SNI standard of 0.3%. AfterNaOH neutralization, the GAC filtered oil contained 1.20% FFA; while the zeolite filtered oil contained1.32%. These FFA contents were definitely higher than the SNI standard, but could satisfy APCC standardfor grade IV coconut oil which is 5%. The refined coconut oils could also satisfy the SNI standard ofsaponification number which is 196 – 206 at minimum. In term of water content, either the filtered or theneutralized oil could also satisfy the SNI standard of 0.3%. In short, the proposed technique could helpfarmers refine their raw coconut oil, and hopefully improve its marketability.

  3. Autonomous water sampling for long-term monitoring of trace metals in remote environments.

    Science.gov (United States)

    Kim, Hyojin; Bishop, James K B; Wood, Todd J; Fung, Inez Y

    2012-10-16

    A remotely controlled autonomous method for long-term high-frequency sampling of environmental waters in remote locations is described. The method which preserves sample integrity of dissolved trace metals and major ions for month-long periods employs a gravitational filtration system (GFS) that separates dissolved and particulate phases as samples are collected. The key elements of GFS are (1) a modified "air-outlet" filter holder to maximize filtration rate and thus minimize filtration artifacts; and (2) the direct delivery of filtrate to dedicated bottle sets for specific analytes. Depth and screen filter types were evaluated with depth filters showing best performance. GFS performance is validated using ground, stream, and estuary waters. Over 30 days of storage, samples with GFS treatment had average recoveries of 95 ± 19% and 105 ± 7% of Fe and Mn, respectively; without GFS treatment, average recoveries were only 16% and 18%. Dissolved major cations K, Mg, and Na were stable independent of collection methodology, whereas Ca in some groundwater samples decreased up to 42% without GFS due to CaCO(3) precipitation. In-field performance of GFS equipped autosamplers is demonstrated using ground and streamwater samples collected at the Angelo Coast Range Reserve, California from October 3 to November 4 2011.

  4. Numerical simulation of HPT processing

    International Nuclear Information System (INIS)

    Verleysen, P; Van den Abeele, F; Degrieck, J

    2014-01-01

    The principle of achieving high strength and superior properties in metal alloys through the application of severe plastic deformation has been exploited in the metal processing industry for many decades. In this contribution finite element simulations are presented of the HPT process. As opposed to most studies in literature, in which rigid sample holders are considered, the real elasto-plastic behavior of the holders is modeled. The simulations show that during the compression stage, plastic deformation occurs in the holders: initially, at the outside boundary of the sample cavity and, at a later stage, underneath the centre of the sample. The latter region of plastic deformation is rapidly growing and has a non-negligible effect on the response of the sample. Major conclusion is that the sample holders, and more specific, their deformability is key for the conditions in the specimen. Indeed, it severely affects important parameters for both the microstructural changes in the sample material, such as the amplitude and distribution of the hydrostatic stress, and its final shape

  5. High-temperature short-time pasteurisation of human breastmilk is efficient in retaining protein and reducing the bacterial count.

    Science.gov (United States)

    Klotz, Daniel; Joellenbeck, Mirjam; Winkler, Karl; Kunze, Mirjam; Huzly, Daniela; Hentschel, Roland

    2017-05-01

    Milk banks are advised to use Holder pasteurisation to inactivate the cytomegalovirus, but the process adversely affects the bioactive properties of human breastmilk. This study explored the antibacterial efficacy of an alternative high-temperature short-time (HTST) treatment of human breastmilk and its effect on marker proteins, compared with the Holder method. Breastmilk samples were obtained from 27 mothers with infants in a German neonatal intensive care unit. The samples were either heated to 62°C for five seconds using HTST or processed using Holder pasteurisation, at 63 ± 0.5°C for 30 minutes. Immunoglobulin A, lactoferrin, lysozyme, alkaline phosphatase and bile salt-stimulated lipase concentrations and bacterial colony-forming units/mL were measured before and after heating. HTST-treated samples retained higher rates of immunoglobulin A (95% versus 83%), alkaline phosphatase (6% versus 0%) and bile salt-stimulated lipase (0.8% versus 0.4%) than Holder pasteurisation samples (all p HTST treatment protocol retained some of the bioactive properties of human breastmilk and appeared to have similar antibacterial efficacy to Holder pasteurisation. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  6. Comparison of bending strain effect on the critical current degradation of Bi-2223 tapes through different measurement techniques

    International Nuclear Information System (INIS)

    Shin, Hyung-Seop; Dizon, John R.C.; Katagiri, Kazumune; Kuroda, Tsuneo

    2006-01-01

    Unlike in the tests under tension, transverse compression and torsion, the bending test of HTS tapes requires lots of time and effort since the sample should be bent or mounted successively onto sample holders having different bending radius at room temperature, and then cooled down to measure the critical current, I c , up to 77 K at each step. In this process, the effect of repeated thermal cycle on the I c degradation can not be ignored. The establishment of a practical and effective measurement method of the critical current as a function of bending strain for HTS tapes should be considered. A ρ-shaped sample holder which provides a series of bending strains to HTS tapes was newly devised. In this case, the connection of Bi-2223 tapes to current terminal blocks was done mechanically. Using this sample holder, the bending strain effect on the I c degradation behavior in Bi-2223 tapes in the easy bending mode was investigated, and discussed them comparing with other data obtained by different testing methods, namely, the conventional bending method using FRP sample holders and the Goldacker-type continuous bending test rig. Commercially available Bi-2223 tapes which have different reinforcing structures were supplied for this study. By using the newly devised ρ-shaped sample holder, it was possible to obtain a bending strain characteristic of I c in Bi-2223 tapes at one time cooling which lessened the testing time significantly when compared with other testing methods and supply good reproducible data. The I c degradation behavior in Bi-2223 tapes was similar to the cases using FRP sample holders although it showed slightly higher I c values

  7. Altitude Performance Characteristics of Turbojet-engine Tail-pipe Burner with Variable-area Exhaust Nozzle Using Several Fuel Systems and Flame Holders

    Science.gov (United States)

    Johnson, Lavern A; Meyer, Carl L

    1950-01-01

    A tail-pipe burner with a variable-area exhaust nozzle was investigated. From five configurations a fuel-distribution system and a flame holder were selected. The best configuration was investigated over a range of altitudes and flight Mach numbers. For the best configuration, an increase in altitude lowered the augmented thrust ratio, exhaust-gas total temperature, and tail-pipe combustion efficiency, and raised the specific fuel consumption. An increase in flight Mach number raised the augmented thrust ratio but had no apparent effect on exhaust-gas total temperature, tail-pipe combustion efficiency, or specific fuel consumption.

  8. Post-purchase reassessment and improvement of neuroendoscope holder: importance of physician-manufacturer communication.

    Science.gov (United States)

    Ogawa, Yoshikazu; Nakata, Yusuke; Tominaga, Teiji

    2014-01-01

    Modern medical management requires constant quality improvement of the various instruments used for surgical procedures. Higher quality, less complicated handling, and reduced maintenance are all desirable qualities. However, any improvements in instrumentation require that surgeons must clearly understand the application of the device by adherence to the manufacturer's instructions. The weakness of this one-way information flow depends on the low interest among medical personnel for post-purchase reassessment. Service industries have research departments to investigate the post-purchase behavior of customers, and service recovery is considered essential to retain customers after service failure. All service providers can suffer service failures, and even the best providers may make errors in delivering service. Such an approach has been increasingly adopted in the risk management at medical institutions. We report our clinical trials of the post-purchase reassessment and product improvement of surgical instrumentation. Medical personnel reassessed the use of a newly developed endoscope holder based on the manufacturer's manual and made recommendations for possible improvements, which were examined by the manufacturer. Simple but important improvement was achieved for reducing the instability and uncertainty of instrument fixation. This bi-directional post-purchase communication between medical personnel and manufacturers can improve risk management in medical institutions.

  9. Shaft seals with an easily removable cylinder holder for low-pressure steam turbines

    Science.gov (United States)

    Zakharov, A. E.; Rodionov, D. A.; Pimenov, E. V.; Sobolev, A. S.

    2016-01-01

    The article is devoted to the problems that occur at the operation of LPC shaft seals (SS) of turbines, particularly, their bearings. The problems arising from the deterioration of oil-protecting rings of SS and bearings and also the consequences in which they can result are considered. The existing SS housing construction types are considered. Their operational features are specified. A new SS construction type with an easily removable holder is presented. The construction of its main elements is described. The sequence of operations of the repair personnel at the restoration of the new SS type spacings is proposed. The comparative analysis of the new and the existing SS construction types is carried out. The assessment results of the efficiency, the operational convenience, and the economic effect after the installation of the new type seals are given. The conclusions about the offered construction prospects are made by results of the comparative analysis and the carried-out assessment. The main advantage of this design is the possibility of spacings restoration both in SS and in oil-protecting rings during a short-term stop of a turbine, even without its cooling. This construction was successfully tested on the working K-300-23.5 LMP turbine. However, its adaptation for other turbines is quite possible.

  10. Is low-energy-ion bombardment generated X-ray emission a secondary mutational source to ion-beam-induced genetic mutation?

    Energy Technology Data Exchange (ETDEWEB)

    Thongkumkoon, P. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand); Prakrajang, K. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Faculty of Science, Maejo University, Chiang Mai 50290 (Thailand); Thopan, P.; Yaopromsiri, C. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Suwannakachorn, D. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand); Yu, L.D., E-mail: yuld@fnrf.science.cmu.ac.th [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2013-07-15

    Highlights: ► Detected X-ray emission from metal, plastic and biological samples. ► Characteristic X-ray emission was detected from metal but not from non-metals. ► Low-energy ion bombarded bacteria held in different sample holders. ► Bacteria held in metal holder had higher mutation rate than in plastic holder. ► Ion-beam-induced X-ray from biological sample is not a basic mutation source. -- Abstract: Low-energy ion beam biotechnology has achieved tremendous successes in inducing crop mutation and gene transfer. However, mechanisms involved in the related processes are not yet well understood. In ion-beam-induced mutation, ion-bombardment-produced X-ray has been proposed to be one of the secondary mutation sources, but the speculation has not yet been experimentally tested. We carried out this investigation to test whether the low-energy ion-beam-produced X-ray was a source of ion-beam-induced mutation. In the investigation, X-ray emission from 29-keV nitrogen- or argon- ion beam bombarded bacterial Escherichia coli (E. coli) cells held in a metal or plastic sample holder was in situ detected using a highly sensitive X-ray detector. The ion beam bombarded bacterial cells held in different material holders were observed for mutation induction. The results led to a conclusion that secondary X-ray emitted from ion-beam-bombarded biological living materials themselves was not a, or at least a negligible, mutational source, but the ion-beam-induced X-ray emission from the metal that made the sample holder could be a source of mutation.

  11. Is low-energy-ion bombardment generated X-ray emission a secondary mutational source to ion-beam-induced genetic mutation?

    International Nuclear Information System (INIS)

    Thongkumkoon, P.; Prakrajang, K.; Thopan, P.; Yaopromsiri, C.; Suwannakachorn, D.; Yu, L.D.

    2013-01-01

    Highlights: ► Detected X-ray emission from metal, plastic and biological samples. ► Characteristic X-ray emission was detected from metal but not from non-metals. ► Low-energy ion bombarded bacteria held in different sample holders. ► Bacteria held in metal holder had higher mutation rate than in plastic holder. ► Ion-beam-induced X-ray from biological sample is not a basic mutation source. -- Abstract: Low-energy ion beam biotechnology has achieved tremendous successes in inducing crop mutation and gene transfer. However, mechanisms involved in the related processes are not yet well understood. In ion-beam-induced mutation, ion-bombardment-produced X-ray has been proposed to be one of the secondary mutation sources, but the speculation has not yet been experimentally tested. We carried out this investigation to test whether the low-energy ion-beam-produced X-ray was a source of ion-beam-induced mutation. In the investigation, X-ray emission from 29-keV nitrogen- or argon- ion beam bombarded bacterial Escherichia coli (E. coli) cells held in a metal or plastic sample holder was in situ detected using a highly sensitive X-ray detector. The ion beam bombarded bacterial cells held in different material holders were observed for mutation induction. The results led to a conclusion that secondary X-ray emitted from ion-beam-bombarded biological living materials themselves was not a, or at least a negligible, mutational source, but the ion-beam-induced X-ray emission from the metal that made the sample holder could be a source of mutation

  12. Device for high-temperature X-ray diffraction analysis. Ustrojstvo dlya vysokotemperaturnogo rentgenostrukturnogo analiza

    Energy Technology Data Exchange (ETDEWEB)

    Epifanov, V G; Zavilinskij, A V; Pet' kov, V V; Polenur, A V

    1975-01-07

    Device for high-temperature X-ray diffraction analysis, containing a vacuum chamber with a window for X-ray transit, in which sample- and standard-holders, heater, thermal shields and means for standard and sample temperature measurement are located, is proposed. In order to increase the working temperature level and the structural change detection accuracy the heater is located between the sample- and standard-holders. The standard-holder is linked with the mechanism of control of its position in relation to the heater. The device is intended for investigating phase transformations by differential thermal analysis method with the simultaneous diffraction pattern detection using X-ray diffractometry method.

  13. X-ray diffraction without sample preparation: Proof-of-principle experiments

    International Nuclear Information System (INIS)

    Hansford, Graeme M.

    2013-01-01

    The properties of a novel X-ray diffraction (XRD) technique having very low sensitivity to the sample morphology were previously elucidated through theoretical considerations and model simulations (Hansford, 2011). This technique opens up the possibility of mineralogical analysis by XRD without sample preparation. Here, the results of proof-of-principle experimental tests are presented. Two sets of experiments were performed using a vacuum chamber equipped with an X-ray tube source, sample holder and charge-coupled detector. Firstly, a pressed-powder pellet of α-quartz was placed in three different positions relative to the X-ray source and detector. The changes in position represent gross sample movements which would be inconceivable in conventional XRD analysis. The resulting back-reflection energy-dispersive spectra show a very high degree of correspondence other than an overall intensity factor dependent on the distance between the sample and detector. Secondly, the back-reflection spectrum of an unprepared limestone hand specimen, having mm-scale surface morphology, was compared to the spectrum of a calcite pressed-powder pellet. The correspondence of the diffraction peaks in the spectra demonstrate that the limestone is comprised dominantly of calcite. In both cases, the claims of the earlier paper are fully supported by the results of these experimental tests. -- Highlights: • Proof-of-principle tests of a novel X-ray diffraction (XRD) method were conducted. • Very low sensitivity to sample position and orientation was demonstrated. • Insensitivity to sample morphology is inferred. • A simple analysis of an unprepared limestone hand specimen was performed. • This technique enables mineralogical analysis by XRD without sample preparation

  14. 40 CFR 1065.170 - Batch sampling for gaseous and PM constituents.

    Science.gov (United States)

    2010-07-01

    ... Materials Emissions Engines Compression-ignition, two-stroke spark ignition, 4-stroke spark-ignition auto changer configurations, you may... environments and should be loaded into cassettes, filter holders, or auto changer apparatus before removal from...

  15. Si(Li)-NaI(Tl) sandwich detector array for measurements of trace radionuclides in soil samples

    International Nuclear Information System (INIS)

    Strauss, M.G.; Sherman, I.S.; Roche, C.T.; Pehl, R.H.

    1986-01-01

    An ultra-sensitive X/γ-ray detector system for assaying trace radioactivity in actinide contaminated soil and ash samples has been developed. The new system consists of an array of 6 large Si(Li) X-ray detectors sensitive on both faces and mounted on edge in a paddle-shaped cryostat with a 14 cm diameter Be window on each side. The paddle, with a sample of the soil placed at each window, is sandwiched between 2 large NaI(Tl) scintillators which suppress the γ background. With X-rays being measured simultaneously from soil in 2 sample holders and background reduced by 50% using anticoincidence, the sensitivity of this detector is 4 times higher than that of conventionally mounted Si(Li) detectors. A soil sample containing 50 pCi/g 239 Pu was measured in 5 min with an uncertainty of 1 and NpLsub(β1) X-ray peaks are resolved thus permitting measurement of trace Pu in the presence of 241 Am. This is the most sensitive and selective detector known for nondestructive assay of radioactivity in soil and other samples. (orig.)

  16. Characterizing Mobile/Less-Mobile Porosity and Solute Exchange in Dual-Domain Media Using Tracer Experiments and Electrical Measurements in a Hassler-Type Core Holder

    Science.gov (United States)

    Falzone, S.; Slater, L. D.; Day-Lewis, F. D.; Parker, B. L.; Keating, K.; Robinson, J.

    2017-12-01

    Mass transfer is the process by which solute is retained in less-mobile porosity domains, and later released into the mobile porosity domain. This process is often responsible for the slow arrival and gradual release of contaminants and solute tracers. Recent studies have outlined methods using dual-domain mass transfer (DDMT) models for characterizing this phenomenon. These models use the non-linear relationship of bulk (σb) and fluid (σf) conductivity, collected from electrical methods during tracer experiments, to characterize the less-mobile/mobile porosity ratio (β) and the mass-transfer rate coefficient (α). DDMT models use the hysteretic σb-σf relationship observed while solute tracers are injected and then flushed from a sample media. Due to limitations in observing the hysteretic σb-σf relationship, this method has not been used to characterize low permeability samples. We have developed an experimental method for testing porous rock cores that allows us to develop a fundamental understanding of contaminant storage and release in consolidated rock. We test the approach on cores from sedimentary rock sites where mass transfer is expected to occur between hydraulically connected fractures and the adjacent low permeability rock matrix. Our method uses a Hassler-type core holder, designed to apply confining pressure around the outside of a sample core, which hydraulically isolates the sample core, allowing water to be injected into it at increased pressures. The experimental apparatus was also designed to measure σb with spectral induced polarization (SIP) measurements, and σf from a sampling port located at the center of the core. Cores were initially saturated with a solution with high electrical conductivity ( 80000 μS/cm). DI water was then injected into the cores at elevated pressures (>60 psi) and the saturating solution was flushed from the cores, in order to generate flow rates fast enough to capture the non-linear σb-σf relationship

  17. THE EFFECT OF COMPETENCE, LEADERSHIP, AND MANAGEMENT INNOVATION OVER THE PERFORMANCE OF STRUCTURAL OFFICIAL OF ECHELON IVB

    Directory of Open Access Journals (Sweden)

    Bedjo Sujanto

    2017-07-01

    Full Text Available The aim of this research was to analyze the effect of competency, leadership, and innovations management on structural office holder of echelon IVB performance.This research was conducted at the One Stop Service Agency of Province of DKI Jakarta, using the method of path analysis in hypothesis testing. The sample in this research is of 75 people with simple random sampling. The results of this study are: (1 Competency positive direct effect on structural office holder echelon IVB performance. (2 Leadership positive direct effect on structural office holder echelon IVB performance. (3 Management of Innovation positive direct effect on structural office holder echelon IVB performance. (4 Competency positive direct effect on Management of Innovation, and (5 Leadership positive direct effect on Management of Innovation.The results of this research has implications for the effect of competency, leadership, and innovations management which can support on the structural office holder of echelon IVB performance One Stop Service Agency of Province of Jakarta Special Capital Region.

  18. Composition and Variation of Macronutrients, Immune Proteins, and Human Milk Oligosaccharides in Human Milk From Nonprofit and Commercial Milk Banks.

    Science.gov (United States)

    Meredith-Dennis, Laura; Xu, Gege; Goonatilleke, Elisha; Lebrilla, Carlito B; Underwood, Mark A; Smilowitz, Jennifer T

    2018-02-01

    When human milk is unavailable, banked milk is recommended for feeding premature infants. Milk banks use processes to eliminate pathogens; however, variability among methods exists. Research aim: The aim of this study was to compare the macronutrient (protein, carbohydrate, fat, energy), immune-protective protein, and human milk oligosaccharide (HMO) content of human milk from three independent milk banks that use pasteurization (Holder vs. vat techniques) or retort sterilization. Randomly acquired human milk samples from three different milk banks ( n = 3 from each bank) were analyzed for macronutrient concentrations using a Fourier transform mid-infrared spectroscopy human milk analyzer. The concentrations of IgA, IgM, IgG, lactoferrin, lysozyme, α-lactalbumin, α antitrypsin, casein, and HMO were analyzed by mass spectrometry. The concentrations of protein and fat were significantly ( p < .05) less in the retort sterilized compared with the Holder and vat pasteurized samples, respectively. The concentrations of all immune-modulating proteins were significantly ( p < .05) less in the retort sterilized samples compared with vat and/or Holder pasteurized samples. The total HMO concentration and HMOs containing fucose, sialic acid, and nonfucosylated neutral sugars were significantly ( p < .05) less in retort sterilized compared with Holder pasteurized samples. Random milk samples that had undergone retort sterilization had significantly less immune-protective proteins and total and specific HMOs compared with samples that had undergone Holder and vat pasteurization. These data suggest that further analysis of the effect of retort sterilization on human milk components is needed prior to widespread adoption of this process.

  19. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Haydn [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of); Marco Parra, Lue-Meru, E-mail: luemerumarco@yahoo.e [Universidad Centroccidental Lisandro Alvarado, Dpto. Quimica y Suelos, Decanato de Agronomia, Tarabana, Cabudare, Edo.Lara (Venezuela, Bolivarian Republic of); Bennun, Leonardo [Universidad de Concepcion, Concepcion (Chile); Greaves, Eduardo D. [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of)

    2010-06-15

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-K{alpha} and Co-K{alpha} lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 {mu}gL{sup -1}. The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  20. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    International Nuclear Information System (INIS)

    Barros, Haydn; Marco Parra, Lue-Meru; Bennun, Leonardo; Greaves, Eduardo D.

    2010-01-01

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-Kα and Co-Kα lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 μgL -1 . The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  1. Study of the effects of E × B fields as mechanism to carbon-nitrogen plasma immersion ion implantation on stainless steel samples

    Science.gov (United States)

    Pillaca, E. J. D. M.; Ueda, M.; Oliveira, R. M.; Pichon, L.

    2014-08-01

    Effects of E × B fields as mechanism to carbon-nitrogen plasma immersion ion implantation (PIII) have been investigated. This magnetic configuration when used in PIII allows obtaining high nitrogen plasma density close to the ion implantation region. Consequently, high ions dose on the target is possible to be achieved compared with standard PIII. In this scenario, nitrogen and carbon ions were implanted simultaneously on stainless steel, as measured by GDOES and detected by X-ray diffraction. Carbon-tape disposed on the sample-holder was sputtered by intense bombardment of nitrogen ions, being the source of carbon atoms in this experiment. The implantation of both N and C caused changes on sample morphology and improvement of the tribological properties of the stainless steel.

  2. DIAGNOSIS OF BANKRUPTCY RISK IN THE FURNITURE INDUSTRY USING THE CANON-HOLDER AND ALTMAN MODELS

    Directory of Open Access Journals (Sweden)

    Radu MĂRGINEAN

    2015-06-01

    Full Text Available The financial and economic crisis that started in 2008 caused negative effects felt by the entire European economy, affecting more or less all of the world's economies. This paper aims to study the diagnosis of bankruptcy risk using the Canon-Holder and Altman methods, from a theoretical point of view and with practical examples on a company in the furniture industry in Romania. In a context of economic uncertainty, the relevance of such an analysis designed to quantify the risk of bankruptcy for companies is the default. The financial data used is real and descriptively analyzed, we analyzed a period of eight years, between 2006-2013. As a method of analysis complementary to the financial analysis of the background of companies, the diagnosis of bankruptcy risk using the score method, using the specific models known in the specialty literature, brings relevant information concerning the problem of risk assessment. We concluded in the case study the opportunity of such an analysis for the furniture industry through the results obtained in the case studies, the method is a useful tool, especially for the practitioners in the sector.

  3. Isotope Investigations at an Alpine Karst Aquifer by Means of On-Site Measurements with High Time Resolution and Near Real-Time Data Availability

    International Nuclear Information System (INIS)

    Leis, A.; Plieschnegger, M.; Harum, T.; Stadler, H.; Schmitt, R.; Pelt, A. Van; Zerobin, W.

    2011-01-01

    For numerous hydrological investigations as the characterization of storage and discharge dynamics at karst springs on-site isotopic measurements with high time resolution could improve the significance of the investigations. Conventional isotope ratio mass spectrometers (IRMS) can only be used in laboratories because of their technical complexity. Since a short time more compact laser based instruments, the so called cavity ringdown spectrometers (CRDS) are commercially available. For on-site use of such an instrument several adaptations are necessary. This concerns especially a direct sample injection from the outflow of the spring, because this is originally not intended. The studied alpine and mountainous karst system is located in the so called Northern Calcareous Alps in Austria reaching altitudes up to approx. 2300 masl. The spring is situated in the Salza-valley at an altitude of approximately 650 masl. The investigated karst spring is a typical limestone spring type according to having well developed karst conduits. The isotopic composition of the water samples were measured by using cavity ring-down spectroscopy with a WS-CRDS (Wavelength-Scanned Cavity Ring-Down Spectroscopy) instrument (Picarro, Inc.). In order to adapt the System for on-site isotope measurements at the spring the laser spectrometer was coupled to an automatic injection module for continuous measurements of liquid samples based on a VALCO valve. The device replaces the auto-sampler and allows quasi-continuous injections of a 2 ul-water samples into the Picarro L1102-iso-water analyzer via the Picarro vaporizer module.

  4. Infrared (IR) photon-sensitive spectromicroscopy in a cryogenic environment

    Science.gov (United States)

    Pereverzev, Sergey

    2016-06-14

    A system designed to suppress thermal radiation background and to allow IR single-photon sensitive spectromicroscopy of small samples by using both absorption, reflection, and emission/luminescence measurements. The system in one embodiment includes: a light source; a plurality of cold mirrors configured to direct light along a beam path; a cold or warm sample holder in the beam path; windows of sample holder (or whole sample holder) are transparent in a spectral region of interest, so they do not emit thermal radiation in the same spectral region of interest; a cold monochromator or other cold spectral device configured to direct a selected fraction of light onto a cold detector; a system of cold apertures and shields positioned along the beam path to prevent unwanted thermal radiation from arriving at the cold monochromator and/or the detector; a plurality of optical, IR and microwave filters positioned along the beam path and configured to adjust a spectral composition of light incident upon the sample under investigation and/or on the detector; a refrigerator configured to maintain the detector at a temperature below 1.0K; and an enclosure configured to: thermally insulate the light source, the plurality of mirrors, the sample holder, the cold monochromator and the refrigerator.

  5. THE REAL ISSUE WITH WALL DEPOSITS IN CLOSED FILTER CASSETTES - WHAT'S THE SAMPLE?

    Energy Technology Data Exchange (ETDEWEB)

    Brisson, M.

    2009-09-12

    The measurement of aerosol dusts has long been utilized to assess the exposure of workers to metals. Tools used to sample and measure aerosol dusts have gone through many transitions over the past century. In particular, there have been several different techniques used to sample for beryllium, not all of which might be expected to produce the same result. Today, beryllium samples are generally collected using filters housed in holders of several different designs, some of which are expected to produce a sample that mimics the human capacity for dust inhalation. The presence of dust on the interior walls of cassettes used to hold filters during metals sampling has been discussed in the literature for a number of metals, including beryllium, with widely varying data. It appears that even in the best designs, particulates can enter the sampling cassette and deposit on the interior walls rather than on the sampling medium. The causes are not well understood but are believed to include particle bounce, electrostatic forces, particle size, particle density, and airflow turbulence. Historically, the filter catch has been considered to be the sample, but the presence of wall deposits, and the potential that the filter catch is not representative of the exposure to the worker, puts that historical position into question. This leads to a fundamental question: What is the sample? This article reviews the background behind the issue, poses the above-mentioned question, and discusses options and a possible path forward for addressing that question.

  6. Lessee´s Liabilities In The Leasing Housing Contract Intended For Family Dwelling Purposes Not Related To His Holder Quality

    Directory of Open Access Journals (Sweden)

    Maria Cristina Arrieta Blanquicett

    2015-07-01

    Full Text Available The leasing housing contract intended for family dwelling purposes was enforced in Colombia for nearly a decade, being quite useful for developing the country economy, in particular for the purchase of home. Despite the usefulness when executing it, several conflicts have arisen, reason why it is mandatory to build a legal regulation harmonized with its philosophy, such as “Creating new long and medium-term home financing mechanisms in Colombia”. All the foregoing in order to give a wide development to the postulate set forth in article 51 of the Political Constitution of 1991 that ensures the right to access to a decent housing. Since the legal regulation of housing leasing intended to family dwelling has been scarce and keeping in mind its atypical nature, it is required to identify what are the liabilities that arise to the contracting parties, in particular to the lessee, taking into account that between him and the good given in leasing there is a tenure relation. The leasing housing contract intended for family dwelling purposes besides of being an atypical contract is also a finance nature contract for which reason the entities authorized to enter into such type of transactions impose to the lessee several clauses that might be unrelated to the holder quality of the lessee; and thus, could turn out to be abusive in the light of the Political Constitution, the law and the doctrine regarding to the protection to the consumer. In conformity with the above mentioned reality, both the legislator and the Constitutional Court have set forth the guidelines to implement the mechanisms that seek for the protection of the lessee, bearing in mind that the subject matter of the housing leasing contract intended to family dwelling falls on a human right. Therefore, it is helpful to identify which are the liabilities of the lessee that are not related to his quality as holder in order to be able to assess them and conclude that they are in conflict

  7. Design of a scanning probe microscope with advanced sample treatment capabilities: An atomic force microscope combined with a miniaturized inductively coupled plasma source

    International Nuclear Information System (INIS)

    Hund, Markus; Herold, Hans

    2007-01-01

    We describe the design and performance of an atomic force microscope (AFM) combined with a miniaturized inductively coupled plasma source working at a radio frequency of 27.12 MHz. State-of-the-art scanning probe microscopes (SPMs) have limited in situ sample treatment capabilities. Aggressive treatments such as plasma etching or harsh treatments such as etching in aggressive liquids typically require the removal of the sample from the microscope. Consequently, time consuming procedures are required if the same sample spot has to be imaged after successive processing steps. We have developed a first prototype of a SPM which features a quasi in situ sample treatment using a modified commercial atomic force microscope. A sample holder is positioned in a special reactor chamber; the AFM tip can be retracted by several millimeters so that the chamber can be closed for a treatment procedure. Most importantly, after the treatment, the tip is moved back to the sample with a lateral drift per process step in the 20 nm regime. The performance of the prototype is characterized by consecutive plasma etching of a nanostructured polymer film

  8. ArF photo resist pattern sample preparation method using FIB without protective coating

    Science.gov (United States)

    Okushima, Hirohisa; Onozuka, Toshihiko; Kuroda, Yasushi; Yaguchi, Toshie; Umemura, Kaoru; Tamochi, Ryuichiro; Watanabe, Kenji; Hasegawa, Norio; Kawata, Isao; Rijpers, Bart

    2006-03-01

    This paper presents a novel method of FIB (FIB: focused ion beam) sample preparation to accurately evaluate critical dimensions and profiles of ArF photo resist patterns without the use of a protective coating on the photo resist. In order to accomplish this, the FIB micro-sampling method that is one of effective FIB milling and fabrication method was employed. First a Si cap is picked up from a silicon wafer and fixed to ArF photo resist patterns to protect against ion beam irradiation. Then, a micro-sample, a piece of Si-capped ArF photo resist, was extracted from the bulk ArF photo resist. In this procedure, this silicon cap always protects ArF photo resist patterns against ion beam irradiation. For the next step, the micro-sample is fixed to a needle stub of the FIB-STEM (STEM: scanning transmission electron microscopy) compatible rotation holder. This sample on the needle stub was rotated 180 degrees and milled from the side of Si substrate. Lastly, the sample is milled to the thickness of 2μm. In this process, the ion beam is irradiating from the silicon substrate side to minimize the ion beam irradiation damages on the ArF photo resist patterns. EDX (EDX: Energy dispersive X-ray spectroscopy) analysis proved that no gallium ions were detected on the surface of the ArF photo resist patterns. The feasibility of high accelerating voltage observation of STEM to observe line edge roughness of a thick sample like 2μm without shrinkage has been demonstrated.

  9. Cross-Cultural Comparative Analysis of Lay and Stake holder Reasoning about Fusion Energy in Spain and the UK

    Energy Technology Data Exchange (ETDEWEB)

    Prades, A; Horlick-Jones, T; Oltra, C; Navajas, J

    2009-07-01

    This report presents the results of a cross-cultural comparative analysis of two corpora of data from Spain and the UK on lay and stake holders understanding and reasoning about fusion energy. The very same novel methodological approach was applied in Spain and the UK to promote a learning and deliberative process about fusion energy. A brief description of the method is included first, followed by the description of the two corpora of data. Next the main Spanish findings data are discussed in the light of the UK data and then vice versa (in other words, we first interrogate the UK corpus of data to look for resonances or places of tension with the Spanish findings, and then the other way around). Then we present the results of evaluating the Spanish and UK group-based processes as engagement exercises. Finally, the key conclusions of this cross-cultural data analysis are summarized. (Author) 40 refs.

  10. Cross-Cultural Comparative Analysis of Lay and Stake holder Reasoning about Fusion Energy in Spain and the UK

    International Nuclear Information System (INIS)

    Prades, A.; Horlick-Jones, T.; Oltra, C.; Navajas, J.

    2009-01-01

    This report presents the results of a cross-cultural comparative analysis of two corpora of data from Spain and the UK on lay and stake holders understanding and reasoning about fusion energy. The very same novel methodological approach was applied in Spain and the UK to promote a learning and deliberative process about fusion energy. A brief description of the method is included first, followed by the description of the two corpora of data. Next the main Spanish findings data are discussed in the light of the UK data and then vice versa (in other words, we first interrogate the UK corpus of data to look for resonances or places of tension with the Spanish findings, and then the other way around). Then we present the results of evaluating the Spanish and UK group-based processes as engagement exercises. Finally, the key conclusions of this cross-cultural data analysis are summarized. (Author) 40 refs.

  11. Electrodeposition as a sample preparation technique for TXRF analysis

    International Nuclear Information System (INIS)

    Griesel, S.; Reus, U.; Prange, A.

    2000-01-01

    TXRF analysis of trace elements at concentrations in the μg/L range and below in high salt matrices normally requires a number of sample preparation steps that include separation of the salt matrix and preconcentration of the trace elements. A neat approach which allows samples to be prepared straightforwardly in a single step involves the application of electrochemical deposition using the TXRF sample support itself as an electrode. For this work a common three-electrode arrangement (radiometer analytical) with a rotating disc electrode as the working electrode, as is frequently employed in voltametric analysis, has been used. A special electrode tip has been constructed as a holder for the sample carrier which consists of polished glassy carbon. This material has been proven to be suitable for both its electrical and chemical properties. Measurements of the trace elements were performed using the ATOMIKA 8030C TXRF spectrometer, with the option of variable incident angles. In first experiments an artificial sea water matrix containing various trace elements in the μg/L range has been used. Elements such as Cr, Mn, Fe, Co, Ni, Cu, Zn, Ag, Cd, Hg, and Pb deposited on glassy carbon carriers. The deposition can be optimized by controlling the potential of the working electrode with respect to the reference electrode. Metal ions with a suitable standard potential are reduced to the metallic state and plated onto the electrode surface. When deposition is finished the sample carrier is demounted, rinsed with ultra-pure water and measured directly. Deposition yields for the elements under investigation are quite similar, and with an appropriate choice of the reference element, quantification can be achieved directly by internal standardization. The influence of parameters such as time, pH value, and trace element concentration on the deposition yield has been examined, and the results will be presented along with reproducibility studies. (author)

  12. Robotic Transnasal Endoscopic Skull Base Surgery: Systematic Review of the Literature and Report of a Novel Prototype for a Hybrid System (Brescia Endoscope Assistant Robotic Holder).

    Science.gov (United States)

    Bolzoni Villaret, Andrea; Doglietto, Francesco; Carobbio, Andrea; Schreiber, Alberto; Panni, Camilla; Piantoni, Enrico; Guida, Giovanni; Fontanella, Marco Maria; Nicolai, Piero; Cassinis, Riccardo

    2017-09-01

    Although robotics has already been applied to several surgical fields, available systems are not designed for endoscopic skull base surgery (ESBS). New conception prototypes have been recently described for ESBS. The aim of this study was to provide a systematic literature review of robotics for ESBS and describe a novel prototype developed at the University of Brescia. PubMed and Scopus databases were searched using a combination of terms, including Robotics OR Robot and Surgery OR Otolaryngology OR Skull Base OR Holder. The retrieved papers were analyzed, recording the following features: interface, tools under robotic control, force feedback, safety systems, setup time, and operative time. A novel hybrid robotic system has been developed and tested in a preclinical setting at the University of Brescia, using an industrial manipulator and readily available off-the-shelf components. A total of 11 robotic prototypes for ESBS were identified. Almost all prototypes present a difficult emergency management as one of the main limits. The Brescia Endoscope Assistant Robotic holder has proven the feasibility of an intuitive robotic movement, using the surgeon's head position: a 6 degree of freedom sensor was used and 2 light sources were added to glasses that were therefore recognized by a commercially available sensor. Robotic system prototypes designed for ESBS and reported in the literature still present significant technical limitations. Hybrid robot assistance has a huge potential and might soon be feasible in ESBS. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. An atomic force microscope for the study of the effects of tip sample interactions on dimensional metrology

    Science.gov (United States)

    Yacoot, Andrew; Koenders, Ludger; Wolff, Helmut

    2007-02-01

    An atomic force microscope (AFM) has been developed for studying interactions between the AFM tip and the sample. Such interactions need to be taken into account when making quantitative measurements. The microscope reported here has both the conventional beam deflection system and a fibre optical interferometer for measuring the movement of the cantilever. Both can be simultaneously used so as to not only servo control the tip movements, but also detect residual movement of the cantilever. Additionally, a high-resolution homodyne differential optical interferometer is used to measure the vertical displacement between the cantilever holder and the sample, thereby providing traceability for vertical height measurements. The instrument is compatible with an x-ray interferometer, thereby facilitating high resolution one-dimensional scans in the X-direction whose metrology is based on the silicon d220 lattice spacing (0.192 nm). This paper concentrates on the first stage of the instrument's development and presents some preliminary results validating the instrument's performance and showing its potential.

  14. Low-Z polymer sample supports for fixed-target serial femtosecond X-ray crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Feld, Geoffrey K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); National Institute of Environmental Health Science, Research Triangle Park, NC (United States); Heymann, Michael [Brandeis Univ., Waltham, MA (United States); Univ. of Hamburg and DESY, Hamburg (Germany); Benner, W. Henry [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pardini, Tommaso [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Tsai, Ching -Ju [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Boutet, Sebastien [SLAC National Accelerator Lab., Menlo Park, CA (United States); Coleman, Matthew A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hunter, Mark S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); SLAC National Accelerator Lab., Menlo Park, CA (United States); Li, Xiaodan [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Messerschmidt, Marc [SLAC National Accelerator Lab., Menlo Park, CA (United States); BioXFEL Science and Technology Center, Buffalo, NY (United States); Opathalage, Achini [Brandeis Univ., Waltham, MA (United States); Pedrini, Bill [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Williams, Garth J. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Krantz, Bryan A. [Univ. of California, Berkeley, CA (United States); Fraden, Seth [Brandeis Univ., Waltham, MA (United States); Hau-Riege, Stefan [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Evans, James E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Segelke, Brent W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Frank, Matthias [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-06-27

    X-ray free-electron lasers (XFELs) offer a new avenue to the structural probing of complex materials, including biomolecules. Delivery of precious sample to the XFEL beam is a key consideration, as the sample of interest must be serially replaced after each destructive pulse. The fixed-target approach to sample delivery involves depositing samples on a thin-film support and subsequent serial introduction via a translating stage. Some classes of biological materials, including two-dimensional protein crystals, must be introduced on fixed-target supports, as they require a flat surface to prevent sample wrinkling. A series of wafer and transmission electron microscopy (TEM)-style grid supports constructed of low-Z plastic have been custom-designed and produced. Aluminium TEM grid holders were engineered, capable of delivering up to 20 different conventional or plastic TEM grids using fixed-target stages available at the Linac Coherent Light Source (LCLS). As proof-of-principle, X-ray diffraction has been demonstrated from two-dimensional crystals of bacteriorhodopsin and three-dimensional crystals of anthrax toxin protective antigen mounted on these supports at the LCLS. In conclusion, the benefits and limitations of these low-Z fixed-target supports are discussed; it is the authors' belief that they represent a viable and efficient alternative to previously reported fixed-target supports for conducting diffraction studies with XFELs.

  15. Selective plane illumination microscopy (SPIM) with time-domain fluorescence lifetime imaging microscopy (FLIM) for volumetric measurement of cleared mouse brain samples

    Science.gov (United States)

    Funane, Tsukasa; Hou, Steven S.; Zoltowska, Katarzyna Marta; van Veluw, Susanne J.; Berezovska, Oksana; Kumar, Anand T. N.; Bacskai, Brian J.

    2018-05-01

    We have developed an imaging technique which combines selective plane illumination microscopy with time-domain fluorescence lifetime imaging microscopy (SPIM-FLIM) for three-dimensional volumetric imaging of cleared mouse brains with micro- to mesoscopic resolution. The main features of the microscope include a wavelength-adjustable pulsed laser source (Ti:sapphire) (near-infrared) laser, a BiBO frequency-doubling photonic crystal, a liquid chamber, an electrically focus-tunable lens, a cuvette based sample holder, and an air (dry) objective lens. The performance of the system was evaluated with a lifetime reference dye and micro-bead phantom measurements. Intensity and lifetime maps of three-dimensional human embryonic kidney (HEK) cell culture samples and cleared mouse brain samples expressing green fluorescent protein (GFP) (donor only) and green and red fluorescent protein [positive Förster (fluorescence) resonance energy transfer] were acquired. The results show that the SPIM-FLIM system can be used for sample sizes ranging from single cells to whole mouse organs and can serve as a powerful tool for medical and biological research.

  16. Illuminating Electron Microscopy of Photocatalysts

    DEFF Research Database (Denmark)

    Cavalca, Filippo

    specimen holder capable of shining light onto samples inside the TEM. The holder contains a laser diode and an optical system that guides light onto a sample with maximum power transmission. The source can be changed and tuned, in principle spanning the whole visible and UV spectrum. It is possible to use...... present preliminary results from Cu2O nanocubes, which show the effect of photodegradation under visible light exposure....

  17. An environmental sample chamber for reliable scanning transmission x-ray microscopy measurements under water vapor

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Stephen T.; Nigge, Pascal; Prakash, Shruti; Gilles, Mary K. [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Laskin, Alexander; Wang, Bingbing [William R. Wiley Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352 (United States); Tyliszczak, Tolek [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Leone, Stephen R. [Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Department of Chemistry and Department of Physics, University of California, Berkeley, California 94720 (United States)

    2013-07-15

    We have designed, fabricated, and tested a compact gas-phase reactor for performing in situ soft x-ray scanning transmission x-ray microscopy (STXM) measurements. The reactor mounts directly to the existing sample holder used in the majority of STXM instruments around the world and installs with minimal instrument reconfiguration. The reactor accommodates many gas atmospheres, but was designed specifically to address the needs of measurements under water vapor. An on-board sensor measures the relative humidity and temperature inside the reactor, minimizing uncertainties associated with measuring these quantities outside the instrument. The reactor reduces x-ray absorption from the process gas by over 85% compared to analogous experiments with the entire STXM instrument filled with process gas. Reduced absorption by the process gas allows data collection at full instrumental resolution, minimizes radiation dose to the sample, and results in much more stable imaging conditions. The reactor is in use at the STXM instruments at beamlines 11.0.2 and 5.3.2.2 at the Advanced Light Source.

  18. Review Paper of Radionuclide Monitoring in Food Sample

    International Nuclear Information System (INIS)

    Noor Fadzilah Yusof; Abdul Kadir Ishak; Wo, Y.M.; Nurrul Assyikeen Mohd Jaffary

    2011-01-01

    The uncontrolled release of radionuclides into the atmospheric and aquatic environments may occur as the result of a nuclear or radiological accident. Monitoring of the accidental release at its source and especially direct monitoring of the environmental contamination with radionuclides is necessary for assessment and application of public protective actions and longer term countermeasures as well as emergency workers' protection. In areas historically contaminated with long lived radionuclides monitoring it is essential to protect the public and substantiation of any radiological incidents. Also, dietary pathways can be contaminated with radioactive materials resulting from natural occurrence or man-made applications especially during routine operation, accidents and migration of radionuclides from radioactive waste disposal repositories into the biosphere. Therefore, efforts should be made to determine the presence of radionuclides in a potentially high radiation area especially in operational nuclear facilities. This paper will review the strategies for food monitoring that has been adapted in most countries to obtain baseline data for future reference. Also, this study is discussing the type of food selection commonly collected as sample for radionuclide analysis in different countries over the years. Sampling procedure and analysis also included in this review for better understanding of the analysis. Stake holders' involvement is considered as an important asset in the establishment of monitoring strategies. As a conclusion, future plans for food monitoring programme in Malaysia are recommended as a preparation to embark on the Nuclear Power Plant programme. (author)

  19. Second research coordination meeting of the coordinated research project 'Development of strategies for the effective monitoring of veterinary drug residues in livestock and livestock products in developing countries' (D3.20.22)

    International Nuclear Information System (INIS)

    2003-01-01

    The second RCM under this CRP was held in Pretoria, South Africa, 3 - 7 November 2003. Eleven of the twelve research contract holders, three research agreement holders and one technical contract holder attended the RCM. The three research agreement holders gave presentations on relevant aspects of veterinary drug residues analysis. The increasingly important role of bioassay techniques such as reporter gene assays for the direct screening of the effects of hormonal and other residues in animal cells and the future role of such assays to complement existing instrumental techniques was highlighted. The technical contract holder and research contract holders reviewed the results of the research and method development performed under the first phase of the CRP. Considerable progress has been made in many aspects of the overall work plan. Several commercial immunoassay methods have been critically evaluated. The main problems identified with these kits were the instability of reagents, notably the enzyme conjugates, resulting in poor performance, and the need for better sample preparation protocols applicable to a wider range of matrices. Work plans have been agreed with several laboratories to attempt to address these problems. Good progress has been made in several laboratories working on the development of in-house ELISA methods for chloramphenicol residues. The laboratories involved have produced and characterized antisera in various species and these will be used with reagents produced by technical contract holders to elaborate assay protocols. Further investigation into aspects such as reagent stability, antibody maturation and assay development using various assay formats is planned. A full set of reagents and protocols for their optimisation in a 125 I radioimmunoassay (RIA) for chloramphenicol have been developed by the technical contract holders and transferred to a research contract holder for further method development. However, this researcher was unable to

  20. A testing apparatus and a method of operating the same

    DEFF Research Database (Denmark)

    2014-01-01

    by other sample holders, and each comprising a first abutment being fixed with respect to the sample holder. The testing apparatus comprises at least one second abutment, and each of the multiple first abutments or the second abutment comprises two separate abutment surfaces. Furthermore either each...... of the multiple first abutments or the second abutment is fixed with respect to the support structure (11), and the testing apparatus further comprises a transport mechanism (7, 12) adapted for relatively moving the other of the multiple first abutments or the second abutment in such a way that each of the first...... abutments on the multiple sample holders sequentially passes the second abutment and so that the two abutment surfaces on either each of the multiple first abutments or the second abutment passes on each side of at least a part of the other abutment....

  1. Goniometer head

    International Nuclear Information System (INIS)

    Dzhazairov-Kakhramanov, V.; Berger, V.D.; Kadyrzhanov, K.K.; Zarifov, R.A.

    1994-01-01

    The goniometer head is an electromechanical instrument that performs the independent transfer of a testing sample on three coordinate axes (X, Y, Z) within limits of ±8 mm and independent rotation relative of these directions. The instrument comprises a sample holder, bellows component and three electrometer drives. The sample holder rotates around the axes X and Y, and is installed on the central arm which rotates around axis Z. One characteristic of this instrument is its independence which allows its use in any camera for researches in the field of radiation physics. 2 figs

  2. Adaptation of closed cycle refrigeration system spectrum to radiation cryochemistry: γ-irradiation, ESR and optical absorption spectroscopy, ITL and RTL of frozen matrices at temperatures down to 14 K

    International Nuclear Information System (INIS)

    Mayer, J.; Plonka, A.; Ratajski, A.; Suwalski, J.P.; Wypych, M.

    1978-01-01

    The adaptation of the commercially available closed cycle refrigeration system Spectrim sup(TM) for radiation cryochemistry experiments with frozen matrices down to 14 K is described. The cold head of Spectrim sup(TM), equipped with vacuum shroud extensions and sample holders proper for the given type of experiments, was contained in lead shields, provided with special entrances for irradiation of samples with 60 Co γ-rays. The shroud extensions used for ESR and optical absorption measurements and the sample holders for isothermal luminescence and radiothermolumininescence measurements are described. (U.K.)

  3. Fluorescence intensity dependence on the propagation plane inclination

    International Nuclear Information System (INIS)

    Fernandez, J.E.; Rubio, Marcelo; Sanchez, H. J.

    1987-01-01

    An experimental confirmation of the fluorescence intensity behaviour with the inclination of the propagation plane (α angle) was carried out. A special angular sample-holder was developed and set up on our X-ray spectrometer. This sample-holder allows different positions of irradiation of the sample modifying the α angle until the maximum angle (α Μ ) is reached in the limit situation. In this work, this maximum angle was 86 deg and the incidence and take off angles were both 45 deg. The sample-holder and the collimation system were carefully lined up. The fluorescent spectra of three National Bureau of Standards (NBS) standard samples were taken for sixteen different α angle positions. The theoretical scheme for both enhanced fluorescent lines and nonenhanced fluorescent lines was confirmed, i.e. the invariance of the primary intensity with the α angle and the decline of the enhanced fluorescence intensities under the same conditions. This experimental confirmation agrees with theoretical prediction: the vanishing of the secondary fluorescence in the extreme case α = π/2. (Author) [es

  4. Developments of a bonding technique for optical materials by a surface activation method

    International Nuclear Information System (INIS)

    Sugiyama, Akira; Oda, Tomohiro; Abe, Tomoyuki; Kusunoki, Isao

    2007-01-01

    We have been developing a pair of sample holder used for optics in the surface activation bonding equipment. The holder can adjust the relative position of samples in the order of sub mm. To study the degree of dislocation appearing crystal surface activated by a fast atomic beam, irradiated sapphire crystals were examined by RBS, XPS, and AFM analysis. The heat treatment recovered the surface roughness of irradiated sapphire when the heating temperature reached at 1573 K. (author)

  5. Development of adjustable head holder couch in H and H cancer radiation therapy

    International Nuclear Information System (INIS)

    Sim, Jae Goo; Song, Ki Won; Kim, Jin Man; Park, Myoung Hwan

    2014-01-01

    In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was 0.4±0.8 mm, 0.8±0.4 mm, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was 0.2±0.8 mm, 1.2±0.4 mm, 2.0±0.4 mm. After adjusting position was X,Y,Z axis was 0.2±0.4, 0.4±0.5 mm, 0.4±0.5 mm

  6. Development of adjustable head holder couch in H and H cancer radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Jae Goo; Song, Ki Won; Kim, Jin Man; Park, Myoung Hwan [Dept. of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-06-15

    In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was 0.4±0.8 mm, 0.8±0.4 mm, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was 0.2±0.8 mm, 1.2±0.4 mm, 2.0±0.4 mm. After adjusting position was X,Y,Z axis was 0.2±0.4, 0.4±0.5 mm, 0.4±0.5 mm

  7. Florentine Renaissance Resources. Online Tratte of Office Holders 1282-1532, Ed. by D. Herlihy, R. Burr Litchfield, A. Molho, R. Barducci, 2000. Online Catasto of 1427, Ed. by D. Herlihy, C. Klapisch-Zuber, Vers. 1.2., Brown University, Providence, R.I.

    Directory of Open Access Journals (Sweden)

    Marco Bicchierai

    2002-12-01

    Full Text Available Florentine Renaissance Resources. - Online Tratte of Office Holders 1282-1532, Edited by David Herlihy, R. Burr Litchfield, Anthony Molho and Roberto Barducci , 2000 - Online Catasto of 1427, Edited by David Herlihy, Christiane Klapisch-Zuber, Version 1.2., Brown University, Providence, R.I. , 1996

  8. Division of nuclear liabilities between different license holders and owners - 59214

    International Nuclear Information System (INIS)

    Lindskog, Staffan; Sjoeblom, Rolf

    2012-01-01

    Sweden was one of the first six countries to build and operate a nuclear power reactor. Thus, there exists a corresponding legacy in terms of liabilities for decommissioning and waste management of the historic facilities. Compliance with the Polluter Pays Principle (PPP) and its corollary on equity between generations implies that plans for decommissioning must be made and funds set aside for its execution. The need for precision in the cost estimates often governs the timing of the technical planning. Cost estimates are treacherous since cost raisers may be identified and evaluated only after considerable efforts have been made. Further complications and challenges arise as a result of changes that take place between construction and decommissioning of facilities in terms of the entities involved as owners, operators, license holders, Authorities and financiers. From this perspective, the present paper summarizes the general legislation as well as the legislation that applies particularly to nuclear activities. It also summarizes the relation between the nuclear decommissioning fund system and financial reporting. Three examples are provided that wholly or partially fall under the Studsvik act (that specifically covers old facilities): - The Aagesta nuclear power plant; - The Ranstad uranium mining and beneficiation facility; - The Neutron Research Laboratory at Studsvik; The findings include the following: - It is important that the legislation be clear as to what is included and not. - The rationale for the legislation should also be clear and well communicated. - Old agreements can be significant for the assessment of liabilities, even in cases where a party may no longer exist. - Support for assessment of when activities are continuing or not (which may have a strong significance for the liability) can be found in court cases on chemically contaminated soil. - Analysis of facilities and the work carried out at different times can be very helpful in

  9. THE LEGAL PROTECTION FOR REAL LAND RIGHT HOLDER IN CASE OF FORGED RINCIK

    Directory of Open Access Journals (Sweden)

    Nirwana Nirwana

    2017-12-01

    Full Text Available The legal Protection For Real Land Right Holder in Case of Forged Rincik. The research aimed to investigate (1 the legal protection for the land owner whose possession was based on rincik evidence, and (2 the legal protection on the good-will buyer based on the forged rincik document used in the land sale transaction. This was the normative legal research, also called the library research or documentary study because the research was only conducted on the written regulations or other legal materials or secondary data consisting of the primary and secondary legal materials. The interview was performed to strengthen the theories and opinions in the research. The research also used the Secondary data. the data were analysed and presented using the qualitative descriptive method. The research result indicate that: (1 the real land owner with rincik possession issued after the year 1960 based on the decision of Indonesian Supreme Court No. 560K / PID / 2008 has not been fully protected due to the fact that the seller is funished for forging the rincik., returning the right to the land owner can not be carried out due to the decision of Indonesian Supreme Court Number. 482 / PK / Pdt / 2014 which make the buyer win, while the real land owner is the directed to sue the land seller to give the compensation: and (2 the legal protection on the good faith buyer based on forget rincik in the land sale transaction has been fully protected and has the ringt to possess the land based on the decision of Indonesian Supreme Court Number. 482/PK/Pdt/2014 because the buyer has bought the land in the presence of Temporary Land Title Registar.

  10. The small goat holders to face food security, poverty and environmental challenges: conditions for experiencing successful projects : Lessons from a comparative analysis in different regions of the world (governance, markets, production systems)

    OpenAIRE

    Dubeuf, Jean-Paul

    2014-01-01

    Farming and agri-food systems have to face urgent social and environmental issues linked between them within the Millennium Development Goals firmed by the International Community. Poverty reduction and food safety is considered as a major challenge as at least 800 million people are suffering hunger and extreme poverty particularly in rural areas. The development of livestock for small holders is often seen as a solution to reduce poverty To explore and document the operational articulation ...

  11. Experience-based knowledge in nuclear and radiological emergency preparedness - involvement of national stake holders. Report from the EURANOS project; Erfaringsbasert kunnskap i norsk atomberedskap - medvirkning fra beroerte parter. Rapport fra EURANOS-prosjektet

    Energy Technology Data Exchange (ETDEWEB)

    Bay-Larsen, I.; Oughton, D.; Liland, A.; Eikelmann, I.M.; Hansen, H.S.

    2009-05-15

    The report identifies and summarises the most important experiences related to long term rehabilitation of contaminated areas after the Chernobyl accident, as phrased by representatives from the agricultural sector (including reindeer herding), primary health care, academia, NGOs, local and regional authorities, as well as national authorities with responsibilities for emergency preparedness within their sector. It also includes recommendations for future collaboration to ensure competence and stake holder involvement in Norwegian nuclear and radiological emergency preparedness. (Author)

  12. Development of feed supplementation strategies for improving ruminant productivity on small-holder farms in Latin America through the use of immunoassay techniques. Proceedings of the final research co-ordination meeting of a co-ordinated research programme

    International Nuclear Information System (INIS)

    1996-05-01

    The result of a CRP completed in 1989 and entitled ''Regional Network for Improving the Reproductive Management of Milk, Meat and Fibre Producing Livestock with the Use of Radioimmunoassay Techniques'' clearly indicated that nutritional inadequacies and livestock management deficiencies were the major factors affecting livestock productivity in Latin America. Based on these conclusions a CRP entitled ''Development of Feed Supplementation Strategies for Improving Ruminant Productivity on Small-holder Farms in Latin America through the Use of Immunoassay Techniques'' was initiated late in the same year. The primary aim of the Programme was to improve the productivity of indigenous ruminant livestock species maintained on typical small-holder farms in the region. Central to the approach was to first identify the nutritional and management constraints which affect reproductive and productive efficiency, and subsequently to devise and test corrective measures which would be practical, sustainable and economically viable. Important related goals of the Programme were to enhance the level of expertise and the educational quality within animal production research institutes in the region, to encourage close contact between scientists and institutions in developing and developed countries and to promote scientific information exchange on a regional basis. Refs, figs, tabs

  13. Development of feed supplementation strategies for improving ruminant productivity on small-holder farms in Latin America through the use of immunoassay techniques. Proceedings of the final research co-ordination meeting of a co-ordinated research programme

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    The result of a CRP completed in 1989 and entitled ``Regional Network for Improving the Reproductive Management of Milk, Meat and Fibre Producing Livestock with the Use of Radioimmunoassay Techniques`` clearly indicated that nutritional inadequacies and livestock management deficiencies were the major factors affecting livestock productivity in Latin America. Based on these conclusions a CRP entitled ``Development of Feed Supplementation Strategies for Improving Ruminant Productivity on Small-holder Farms in Latin America through the Use of Immunoassay Techniques`` was initiated late in the same year. The primary aim of the Programme was to improve the productivity of indigenous ruminant livestock species maintained on typical small-holder farms in the region. Central to the approach was to first identify the nutritional and management constraints which affect reproductive and productive efficiency, and subsequently to devise and test corrective measures which would be practical, sustainable and economically viable. Important related goals of the Programme were to enhance the level of expertise and the educational quality within animal production research institutes in the region, to encourage close contact between scientists and institutions in developing and developed countries and to promote scientific information exchange on a regional basis. Refs, figs, tabs.

  14. Dual Source Time-of-flight Mass Spectrometer and Sample Handling System

    Science.gov (United States)

    Brinckerhoff, W.; Mahaffy, P.; Cornish, T.; Cheng, A.; Gorevan, S.; Niemann, H.; Harpold, D.; Rafeek, S.; Yucht, D.

    We present details of an instrument under development for potential NASA missions to planets and small bodies. The instrument comprises a dual ionization source (laser and electron impact) time-of-flight mass spectrometer (TOF-MS) and a carousel sam- ple handling system for in situ analysis of solid materials acquired by, e.g., a coring drill. This DSTOF instrument could be deployed on a fixed lander or a rover, and has an open design that would accommodate measurements by additional instruments. The sample handling system (SHS) is based on a multi-well carousel, originally de- signed for Champollion/DS4. Solid samples, in the form of drill cores or as loose chips or fines, are inserted through an access port, sealed in vacuum, and transported around the carousel to a pyrolysis cell and/or directly to the TOF-MS inlet. Samples at the TOF-MS inlet are xy-addressable for laser or optical microprobe. Cups may be ejected from their holders for analyzing multiple samples or caching them for return. Samples are analyzed with laser desorption and evolved-gas/electron-impact sources. The dual ion source permits studies of elemental, isotopic, and molecular composition of unprepared samples with a single mass spectrometer. Pulsed laser desorption per- mits the measurement of abundance and isotope ratios of refractory elements, as well as the detection of high-mass organic molecules in solid samples. Evolved gas analysis permits similar measurements of the more volatile species in solids and aerosols. The TOF-MS is based on previous miniature prototypes at JHU/APL that feature high sensitivity and a wide mass range. The laser mode, in which the sample cup is directly below the TOF-MS inlet, permits both ablation and desorption measurements, to cover elemental and molecular species, respectively. In the evolved gas mode, sample cups are raised into a small pyrolysis cell and heated, producing a neutral gas that is elec- tron ionized and pulsed into the TOF-MS. (Any imaging

  15. Fiber optical assembly for fluorescence spectrometry

    Science.gov (United States)

    Carpenter, II, Robert W.; Rubenstein, Richard; Piltch, Martin; Gray, Perry

    2010-12-07

    A system for analyzing a sample for the presence of an analyte in a sample. The system includes a sample holder for containing the sample; an excitation source, such as a laser, and at least one linear array radially disposed about the sample holder. Radiation from the excitation source is directed to the sample, and the radiation induces fluorescent light in the sample. Each linear array includes a plurality of fused silica optical fibers that receive the fluorescent light and transmits a fluorescent light signal from the first end to an optical end port of the linear array. An end port assembly having a photo-detector is optically coupled to the optical end port. The photo-detector detects the fluorescent light signal and converts the fluorescent light signal into an electrical signal.

  16. Advances in the sample preparation and the detector for a combined solvent extraction-liquid scintillation method of low-level plutonium measurement

    International Nuclear Information System (INIS)

    Perdue, P.T.; Christian, D.J.; Thorngate, J.H.; McDowell, W.J.; Case, G.N.

    1976-07-01

    A combined solvent extraction-liquid scintillation technique, developed at Oak Ridge National Laboratory (ORNL), has many possible applications to the determination of low levels of plutonium and other alpha-emitting nuclides. Using these procedures, plutonium can be extracted from biological or environmental samples and introduced directly into a liquid scintillator. Quenching of the scintillator is thus minimized so that spectroscopic techniques may be employed. Existing chemical procedures and counting equipment were reviewed and improved. Purification of the di(2-ethylhexyl)phosphoric acid (used as the actinide extractant) was found necessary. Destruction of organic material in the sample and control of the valence state of plutonium were found to be major sources of irreproducibility. Methods were developed to allow samples separated with commonly used ion exchange techniques to be extracted into the scintillator. Comparisons were made of a wide variety of the components and parameters of the detector system to find the best combination of pulse-height resolution and pulse-shape discrimination. When a single phototube was used, optimum performance was obtained using a hemispherical reflector-sample holder viewed sideways by an RCA 8575 photomultiplier tube used in conjunction with a special integrating preamplifier and a good quality linear amplifier that used delay lines to shape the pulses

  17. Process-response coastal-recession model and its application to the Holderness coast (UK); Modelo proceso-respuesta de recesion de acantilados por variacion del nivel del mar. Aplicacion en la Costa de Holderness (Reino Unido)

    Energy Technology Data Exchange (ETDEWEB)

    Castedo, R.; Paredes, C.; Fernandez, M.; Vega, R. de la

    2012-11-01

    At the moment the development of predictive cliff-erosion models is limited from a geomorphologic perspective due to the complex interactions existing between coupled processes acting over wide scales of time and space. Current models incorporate a probabilistic framework in order to simulate coastal recession events or cliff failure and tend to assess the effects of climate change through changes in the mean sea lea level. According to this procedure, the resulting simulations of cliffs with different behaviours might produce identical annual retreat characteristics even if their potential response to changing environments may not be the same. Thus, a new process-response model is developed to incorporate the behavioural characteristics of cohesive clay coasts with a protective talus wedge under erosive processes. To this end, the model incorporates dynamic marine processes such as variations in mean sea level, tides and waves together with cliff evolution in the shape of erosion, cliff failure and the formation of foot talus deposits. Cliff erosion is calculated on the basis of sea-level changes, wave incidence, shore platform slope and the uniaxial compressive strength of the rock over each tidal cycle. After each cycle the geomechanical stability against topple movement of the cliff face is evaluated and in the event of failure, a talus wedge is formed. The model has been corroborated by an assessment of profile evolution at various locations along a rapidly retreating area on the coast of Holderness in the UK. The results represent an important step-forward in linking material properties to cliff recession processes and the subsequent long-term coastal response in the face of changing sea-level conditions. (Author) 72 refs.

  18. Materijalna motivacija kao nosilac uspešne reorganizacije kompanije NIS (Material Motivation as the Holder of a Successful Reorganization on the Example of Company Nis

    Directory of Open Access Journals (Sweden)

    Radmila Stojanović

    2015-04-01

    Full Text Available For successful organization people are the primary development resource. Motivation and satisfaction of employees become the basis of modern organizations. Motivated employees today represent a strategic resource which gain a competitive advantage for the organization. If someone wants to motivate others, must first be able to motivate yourself. That means that if in organization exists motivated staff, there must be a motivated manager who will be able to launch employees. The aim of this paper is to emphasizes the importance of material motivation for successful business of a large company that had in the past significant organizational change. Through unstructured interviews were collected data on which was investigated the hypothesis that the material motivation of the most important holder for successful reorganization on the example of leading Serbian company for exploration, production and refining of oil and gas NIS. From the above it can be concluded that high-quality human resources management involves proper motivation system, that has been based on material incentives. In this paper, attention will be focused on monetary motivation and how a well-established system of material incentives can lead to the great success of the company that had a significant reorganization in the past. It will be shown in detail the system of material incentives and the positive results which obtained by this system, when it comes to the business of the company, which today is the most desirable employer in Serbia and the region. The paper should emphasize the benefits of a fair system of motivation which brings to an organization, but also to encourage further thinking to improve this aspect of motivation, which is a prerequisite for successful business and the basis for all other activities in the HRM. The analysis results indeed show that a system of material incentives in NIS is the holder of a successful reorganization, and the proof is the business

  19. Design of shared instruments to utilize simulated gravities generated by a large-gradient, high-field superconducting magnet.

    Science.gov (United States)

    Wang, Y; Yin, D C; Liu, Y M; Shi, J Z; Lu, H M; Shi, Z H; Qian, A R; Shang, P

    2011-03-01

    A high-field superconducting magnet can provide both high-magnetic fields and large-field gradients, which can be used as a special environment for research or practical applications in materials processing, life science studies, physical and chemical reactions, etc. To make full use of a superconducting magnet, shared instruments (the operating platform, sample holders, temperature controller, and observation system) must be prepared as prerequisites. This paper introduces the design of a set of sample holders and a temperature controller in detail with an emphasis on validating the performance of the force and temperature sensors in the high-magnetic field.

  20. Development of a Test to Evaluate Aerothermal Response of Materials to Hypersonic Flow Using a Scramjet Wind Tunnel (Postprint)

    Science.gov (United States)

    2010-05-01

    prevent the possible slip of the sample within the dovetail. The dovetail holder was made of inconel and was attached to the tube by TIG welding . Moni...Composite Materials and Processing Section Composite Materials and Processing Section Composite Branch...dovetail ( welded ) 0.775" 0.156" hole Coolant (water) Set screws 0.625" OD 0.049" wall TBC Cooled metallic holder Ceramic TC Fig. 4. Schematic sketches of

  1. The guiding principles of the IRPA on the involvement of interested parties (Stake holders) in the management of radiation protection; Los principios orientativos de la IRPA sobre la implicacion de las partes interesadas (Stakeholders) en la gestion de la proteccion radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Arranz, L.; Carboneras, P.; Gallego, E.; Garcia, A.; Rodriguez, M.

    2011-07-01

    There is general consensus that the effective and well structured involvement of interested parties (stake holders) improves the quality of decision making and can achieve more effective and sustainable decisions that generate greater confidence among people and groups affected. The International Radiation Protection Association (IRPA) could not remain indifferent to this issue and has prepared a document of guiding principles for consideration, recommends to its members.

  2. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    International Nuclear Information System (INIS)

    Lalander, Cecilia Helena; Komakech, Allan John; Vinnerås, Björn

    2015-01-01

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies

  3. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    Energy Technology Data Exchange (ETDEWEB)

    Lalander, Cecilia Helena, E-mail: cecilia.lalander@slu.se [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Komakech, Allan John [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Department of Agricultural & Bio-systems Engineering, Makerere University, Kampala (Uganda); Vinnerås, Björn [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden)

    2015-05-15

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies.

  4. Canadian Public and Stake holder Engagement Approach to a Spent Nuclear Fuel Management

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Yong Soo; Kim, Youn Ok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Whang, Joo Ho [Kyunghee University, Yongin (Korea, Republic of)

    2008-09-15

    After Canada has struggled with a radioactive waste problem over for 20 years, the Canadian government finally found out that its approach by far has been lack of social acceptance, and needed a program such as public and stake holder engagement (PSE) which involves the public in decision-making process. Therefore, the government made a special law, called Nuclear Fuel Waste Act (NFWA), to search for an appropriate nuclear waste management approach. NFWA laid out three possible approaches which were already prepared in advance by a nuclear expert group, and required Nuclear Waste Management Organization (NWMO) to be established to report a recommendation as to which of the proposed approaches should be adopted. However, NFWA allowed NWMO to consider additional management approach if the other three were not acceptable enough. Thus, NWMO studied and created a fourth management approach after it had undertaken an comparison of the benefits, risks and costs of each management approach: Adaptive Phased Management. This approach was intended to enable the implementers to accept any technological advancement or changes even in the middle of the implementation of the plan. The Canadian PSE case well shows that technological R and D are deeply connected with social acceptance. Even though the developments and technological advancement are carried out by the scientists and experts, but it is important to collect the public opinion by involving them to the decision-making process in order to achieve objective validity on the R and D programs. Moreover, in an effort to ensure the principles such as fairness, public health and safety, security, and adoptability, NWMO tried to make those abstract ideas more specific and help the public understand the meaning of each concept more in detail. Also, they utilized a variety of communication methods from face-to-face meeting to e-dialogue to encourage people to participate in the program as much as possible. Given the fact that Korea

  5. Canadian Public and Stake holder Engagement Approach to a Spent Nuclear Fuel Management

    International Nuclear Information System (INIS)

    Hwang, Yong Soo; Kim, Youn Ok; Whang, Joo Ho

    2008-01-01

    After Canada has struggled with a radioactive waste problem over for 20 years, the Canadian government finally found out that its approach by far has been lack of social acceptance, and needed a program such as public and stake holder engagement (PSE) which involves the public in decision-making process. Therefore, the government made a special law, called Nuclear Fuel Waste Act (NFWA), to search for an appropriate nuclear waste management approach. NFWA laid out three possible approaches which were already prepared in advance by a nuclear expert group, and required Nuclear Waste Management Organization (NWMO) to be established to report a recommendation as to which of the proposed approaches should be adopted. However, NFWA allowed NWMO to consider additional management approach if the other three were not acceptable enough. Thus, NWMO studied and created a fourth management approach after it had undertaken an comparison of the benefits, risks and costs of each management approach: Adaptive Phased Management. This approach was intended to enable the implementers to accept any technological advancement or changes even in the middle of the implementation of the plan. The Canadian PSE case well shows that technological R and D are deeply connected with social acceptance. Even though the developments and technological advancement are carried out by the scientists and experts, but it is important to collect the public opinion by involving them to the decision-making process in order to achieve objective validity on the R and D programs. Moreover, in an effort to ensure the principles such as fairness, public health and safety, security, and adoptability, NWMO tried to make those abstract ideas more specific and help the public understand the meaning of each concept more in detail. Also, they utilized a variety of communication methods from face-to-face meeting to e-dialogue to encourage people to participate in the program as much as possible. Given the fact that Korea

  6. The effect of UV-C pasteurization on bacteriostatic properties and immunological proteins of donor human milk.

    Science.gov (United States)

    Christen, Lukas; Lai, Ching Tat; Hartmann, Ben; Hartmann, Peter E; Geddes, Donna T

    2013-01-01

    Human milk possesses bacteriostatic properties, largely due to the presence of immunological proteins. Heat treatments such as Holder pasteurization reduce the concentration of immunological proteins in human milk and consequently increase the bacterial growth rate. This study investigated the bacterial growth rate and the immunological protein concentration of ultraviolet (UV-C) irradiated, Holder pasteurized and untreated human milk. Samples (n=10) of untreated, Holder pasteurized and UV-C irradiated human milk were inoculated with E. coli and S. aureus and the growth rate over 2 hours incubation time at 37°C was observed. Additionally, the concentration of sIgA, lactoferrin and lysozyme of untreated and treated human milk was analyzed. The bacterial growth rate of untreated and UV-C irradiated human milk was not significantly different. The bacterial growth rate of Holder pasteurized human milk was double compared to untreated human milk (ppasteurization, resulting in bacteriostatic properties similar to those of untreated human milk.

  7. Transient simulations in WWER-1000-comparison between DYN3D-ATHLET and DYN3D-RELAP5

    International Nuclear Information System (INIS)

    Grundmann, U.; Kliem, S.; Kozmenkov, Y.; Mittag, S.; Rohde, U.; Weiss, F.P.

    2003-01-01

    Simulations of a real transient of an operating WWER-1000 power plant have been performed using DYN3D-ATHLET (Gru95) and DYN3D-RELAP5 (Koy01) code systems in the frame of activities aimed at a validation of the neutronic / thermal-hydraulic coupled codes. The transient initiated by a main coolant pump switching off, when three of the four main coolant pumps of the plant are in operation (scenario of the VALCO project) is chosen for the simulation. The same models of the plant (except the core nodalization) but two different libraries of macroscopic cross-sections have been used in compared calculations. Additionally, the compared code systems are based on the different / external and internal / coupling techniques. This paper contains a brief description of the coupled codes and the plant model as well as a comparison between the results from simulations (Authors)

  8. Dishevelled binds the Discs large 'Hook' domain to activate GukHolder-dependent spindle positioning in Drosophila.

    Directory of Open Access Journals (Sweden)

    Joshua D Garcia

    Full Text Available Communication between cortical cell polarity cues and the mitotic spindle ensures proper orientation of cell divisions within complex tissues. Defects in mitotic spindle positioning have been linked to various developmental disorders and have recently emerged as a potential contributor to tumorigenesis. Despite the importance of this process to human health, the molecular mechanisms that regulate spindle orientation are not fully understood. Moreover, it remains unclear how diverse cortical polarity complexes might cooperate to influence spindle positioning. We and others have demonstrated spindle orientation roles for Dishevelled (Dsh, a key regulator of planar cell polarity, and Discs large (Dlg, a conserved apico-basal cell polarity regulator, effects which were previously thought to operate within distinct molecular pathways. Here we identify a novel direct interaction between the Dsh-PDZ domain and the alternatively spliced "I3-insert" of the Dlg-Hook domain, thus establishing a potential convergent Dsh/Dlg pathway. Furthermore, we identify a Dlg sequence motif necessary for the Dsh interaction that shares homology to the site of Dsh binding in the Frizzled receptor. Expression of Dsh enhanced Dlg-mediated spindle positioning similar to deletion of the Hook domain. This Dsh-mediated activation was dependent on the Dlg-binding partner, GukHolder (GukH. These results suggest that Dsh binding may regulate core interdomain conformational dynamics previously described for Dlg. Together, our results identify Dlg as an effector of Dsh signaling and demonstrate a Dsh-mediated mechanism for the activation of Dlg/GukH-dependent spindle positioning. Cooperation between these two evolutionarily-conserved cell polarity pathways could have important implications to both the development and maintenance of tissue homeostasis in animals.

  9. Social object play among young Japanese macaques (Macaca fuscata) in Arashiyama, Japan.

    Science.gov (United States)

    Shimada, Masaki

    2006-10-01

    Social object play (SOP), i.e., social play using portable object(s), among young Japanese macaques (Macaca fuscata; 0-4 years old) in the Arashiyama E troop was studied using a modified sequence sampling method from July to October 2000. SOP was a relatively common activity for most of the young macaques and often continued for long periods. Participants used many kinds of object, including edible natural objects and artificial objects, such as plastic bottles, but they never used provisioned food or wild fruit in SOP bouts. An analysis of long bouts (>/=0.5 min) revealed the following interactive SOP features: (1) at any given time, participants used only one object, and only one participant held the object; (2) during SOP play-chasing, the object holder was likely to be chased by others; (3) during long bouts, the object changed hands frequently; and (4) agonistic competition for an object among young macaques was rare. Combinations of sexes, ages, relative ranks, or matrilines of the object holder and non-holder did not affect the tendency that the holder was chased by non-holder(s) during play-chasing. Even when there was a change in object holders, the repetitiveness of this interactive pattern, i.e., that the holder would be chased during SOP bouts, distinguished the SOP structure from that of other types of social play without object(s). General proximate social play mechanisms, such as self-handicapping or role taking, were associated with SOP. Other mechanisms that affected SOP included the following: (1) young macaques treated an object as a target in play competition, and (2) 'being the holder of a target object' was associated with the 'role of the chasee.'

  10. 40 CFR 86.1310-2007 - Exhaust gas sampling and analytical system for gaseous emissions from heavy-duty diesel-fueled...

    Science.gov (United States)

    2010-07-01

    ... SAE Recommended Practice J1151, “Methane Measurement Using Gas Chromatography” (1994 SAE Handbook... the filter holder may be adapted, using sound engineering judgment and leak-free construction, to an... shows acceptable variation from the design in 40 CFR part 50, appendix L. Similar variations using sound...

  11. An outdoor investigation of the absorption degradation of single ...

    Indian Academy of Sciences (India)

    Fort Hare Institute of Technology (FHIT), Chemistry Building, 3rd Floor, University of Fort Hare,. Private Bag x1314, Alice 5700, South Africa. ∗ .... air was used to clean the sample surface which was placed under a closed sample holder.

  12. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products.

    Science.gov (United States)

    Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.

  13. ANALISIS KEBERLANJUTAN KAWASAN USAHA PERKEBUNAN KOPI (KUPK RAKYAT DI DESA SIDOMULYO KABUPATEN JEMBER

    Directory of Open Access Journals (Sweden)

    Elida Novita

    2012-05-01

    Full Text Available Sustainability Analysis of Smallholder Coffee Plantation at Sidomulyo Village, Jember District ABSTRAK Desa Sidomulyo, Kecamatan Silo merupakan salah satu sentra produksi kopi rakyat utama di Kabupaten Jember. Perkembangan produksi dan harga kopi dunia yang tidak pasti dapat berimplikasi terhadap keberlanjutan usaha pertanian kopi rakyat. Tujuan penelitian ini adalah untuk mengevaluasi keberlanjutan usaha kopi rakyat di Desa Sidomulyo, Kabupaten Jember. Berdasarkan purposive and random sampling survey, penelitian ini menggunakan kuesioner dan diskusi dengan pihak terkait dalam pengambilan data. Dimensi ekologi, sosial kelembagaan, ekonomi dan teknologi dianalisis dengan menggunakan program Rap-Coffee hasil modifi kasi dari program Rapfi sh. Berdasarkan simulasi program Rap-Coffee untuk keempat dimensi keberlanjutan, maka Indeks Keberlanjutan KUPK Desa Sidomulyo adalah 59,5 % yang berarti berlanjut. Indeks keberlanjutan ini dapat ditingkatkan melalui perbaikan terhadap faktor pengungkit (indikator sensitif. Oleh karena itu di dalam perencanaan kebijakan untuk pengembangan KUPK Desa Sidomulyo sebaiknya memprioritaskan pada peningkatan indikator yang memiliki sensitivitas tinggi di masing-masing dimensi. Kata kunci: Kopi, analisis keberlanjutan, perkebunan rakyat   ABSTRACT Sidomulyo village, Silo region is one of main small holder coffee producer at Jember district. Unpredictable world production and price can cause unsustainability of small holder coffee production. The research objective was to evaluate sustainability of small holder coffee plantation in Sidomulyo, Jember district. Based on purposive and random sampling survey, questionnaire and discussion with key persons were implemented in this research in collecting data. Dimension of ecology, social institutional, economic and technology were analyzed using Rap-Coffee program modified from Rapfi sh software. The result reveals that from four dimensions implemented in this research, the

  14. Open Probe fast GC-MS - combining ambient sampling ultra-fast separation and in-vacuum ionization for real-time analysis.

    Science.gov (United States)

    Keshet, U; Alon, T; Fialkov, A B; Amirav, A

    2017-07-01

    An Open Probe inlet was combined with a low thermal mass ultra-fast gas chromatograph (GC), in-vacuum electron ionization ion source and a mass spectrometer (MS) of GC-MS for obtaining real-time analysis with separation. The Open Probe enables ambient sampling via sample vaporization in an oven that is open to room air, and the ultra-fast GC provides ~30-s separation, while if no separation is required, it can act as a transfer line with 2 to 3-s sample transfer time. Sample analysis is as simple as touching the sample, pushing the sample holder into the Open Probe oven and obtaining the results in 30 s. The Open Probe fast GC was mounted on a standard Agilent 7890 GC that was coupled with an Agilent 5977A MS. Open Probe fast GC-MS provides real-time analysis combined with GC separation and library identification, and it uses the low-cost MS of GC-MS. The operation of Open Probe fast GC-MS is demonstrated in the 30-s separation and 50-s full analysis cycle time of tetrahydrocannabinol and cannabinol in Cannabis flower, sub 1-min analysis of trace trinitrotoluene transferred from a finger onto a glass surface, vitamin E in canola oil, sterols in olive oil, polybrominated flame retardants in plastics, alprazolam in Xanax drug pill and free fatty acids and cholesterol in human blood. The extrapolated limit of detection for pyrene is Open Probe fast GC-MS is demonstrated in the analysis of heroin in its street drug powder. The use of Open Probe with the fast GC acting as a transfer line is demonstrated in <10-s analysis without separation of ibuprofen and estradiol. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Baseline risk assessment of groundwater contamination at the uranium mill tailings site, near Gunnison, Colorado. Revision 2

    International Nuclear Information System (INIS)

    1996-06-01

    This report is the second site-specific risk assessment document prepared for the Ground Water Project at the Gunnison site. A preliminary risk assessment was conducted in 1990 to determine whether long-term use of ground water from private wells near the Gunnison site had the potential for adverse health effects. Due to the results of that preliminary risk assessment, the residents were provided bottled water on an interim basis. In July 1994, the residents and the nearby Valco cement/concrete plant were given the option to connect to anew alternate water supply system, eliminating the bottled water option. This document evaluates current and potential future impacts to the public and the environment from exposure to contaminated ground water. The results of this evaluation and further site characterization will be used to determine whether more action is needed to protect human health and the environment and to comply with the EPA standards

  16. Baseline risk assessment of groundwater contamination at the uranium mill tailings site, near Gunnison, Colorado. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    This report is the second site-specific risk assessment document prepared for the Ground Water Project at the Gunnison site. A preliminary risk assessment was conducted in 1990 to determine whether long-term use of ground water from private wells near the Gunnison site had the potential for adverse health effects. Due to the results of that preliminary risk assessment, the residents were provided bottled water on an interim basis. In July 1994, the residents and the nearby Valco cement/concrete plant were given the option to connect to anew alternate water supply system, eliminating the bottled water option. This document evaluates current and potential future impacts to the public and the environment from exposure to contaminated ground water. The results of this evaluation and further site characterization will be used to determine whether more action is needed to protect human health and the environment and to comply with the EPA standards.

  17. Resistor holder

    Science.gov (United States)

    Broadhurst, John H.

    1989-01-01

    A resistor device for use with electrostatic particle accelerators includes a resistor element positioned within a tubular housing having a fixed end cap at one end thereof and a movable end cap at the other end thereof. The tubular housing, fixed end cap, and movable end cap serve as an electromagnetic field for the resistor element. Conductive disks engage opposite ends of the resistor element and concentrically position the resistor element within the tubular housing. Helical springs engage the conductive disks and the end caps to yieldably support the movable end caps and resistor element for yieldable axial movement relative to the tubular housing. An annular conducting ring is secured to the tubular housing and is spaced radially from the movable end cap and cooperates with the latter to define an annular spark gap.

  18. Evaluation of Legionella real-time PCR against traditional culture for routine and public health testing of water samples.

    Science.gov (United States)

    Collins, S; Stevenson, D; Walker, J; Bennett, A

    2017-06-01

    To evaluate the usefulness of Legionella qPCR alongside traditional culture for enumeration of Legionella from water samples as part of both routine and public health investigation testing. Routine water samples (n = 2002) and samples from public health investigations (n = 215) were analysed by culture and qPCR for Legionella spp., Legionella pneumophila and L. pneumophila sg-1. A negative qPCR result was highly predictive of a negative culture result for all water systems (negative predictive values, NPV from 97·4 to 100%). Positive predictive values (PPV) were lower (0-50%). Results for qPCR were generally larger than culture with average log 10 differences of 1·1 for Legionella spp. and 1·2 for L. pneumophila. Alert and action levels of 1000 and 10 000 GU per litre, respectively, are proposed for Legionella qPCR for hot and cold water systems (HCWS). The use of qPCR significantly reduced the time to results for public health investigations by rapidly identifying potential sources and ruling out others, thus enabling a more rapid and efficient response. The high NPV of qPCR supports its use to rapidly screen out negative samples without culture. Alert and action levels for Legionella qPCR for HCWS are proposed. Quantitative PCR will be a valuable tool for both routine and public health testing. This study generated comparative data of >2000 water samples by qPCR and culture. Action and alert levels have been recommended that could enable duty holders to interpret qPCR results to facilitate timely Legionella control and public health protection. © 2017 Crown copyright. Journal of Applied Microbiology © 2017 The Society for Applied Microbiology.

  19. Laser Plasma Soft X-ray Microscope with Wolter Mirrors for Observation of Biological Specimens in Air

    Science.gov (United States)

    Hoshino, Masato; Aoki, Sadao

    2006-02-01

    A laser plasma soft X-ray microscope with Wolter mirrors was developed so that specimens could be set in the atmosphere. Silicon nitride membranes 100 nm thick were used as vacuum-tight windows. Using relatively large windows (0.46× 0.46 mm2), an adequate working distance for samples, which was approximately 1.2 mm, was assured. The endurance of the vacuum-tight window was measured briefly. Dry biological cells could be observed with resolution better than 100 nm. A preliminary observation of wet biological cells was carried out using a wet environmental sample holder which was composed of only two sheets of silicon nitride membrane. An X-ray micrograph of wet red blood cells from a chicken was obtained without apparent effects of radiation damage. The properties of a vacuum-tight window and a wet sample holder are discussed.

  20. Dielectric characterization of materials at microwave frequency range

    Directory of Open Access Journals (Sweden)

    J. de los Santos

    2003-01-01

    Full Text Available In this study a coaxial line was used to connect a microwave-frequency Network Analyzer and a base moving sample holder for dielectric characterization of ferroelectric materials in the microwave range. The main innovation of the technique is the introduction of a special sample holder that eliminates the air gap effect by pressing sample using a fine pressure system control. The device was preliminary tested with alumina (Al2O3 ceramics and validated up to 2 GHz. Dielectric measurements of lanthanum and manganese modified lead titanate (PLTM ceramics were carried out in order to evaluate the technique for a high permittivity material in the microwave range. Results showed that such method is very useful for materials with high dielectric permittivities, which is generally a limiting factor of other techniques in the frequency range from 50 MHz to 2 GHz.

  1. A novel rotating experimental platform in a superconducting magnet.

    Science.gov (United States)

    Chen, Da; Cao, Hui-Ling; Ye, Ya-Jing; Dong, Chen; Liu, Yong-Ming; Shang, Peng; Yin, Da-Chuan

    2016-08-01

    This paper introduces a novel platform designed to be used in a strong static magnetic field (in a superconducting magnet). The platform is a sample holder that rotates in the strong magnetic field. Any samples placed in the platform will rotate due to the rotation of the sample holder. With this platform, a number of experiments such as material processing, culture of biological systems, chemical reactions, or other processes can be carried out. In this report, we present some preliminary experiments (protein crystallization, cell culture, and seed germination) conducted using this platform. The experimental results showed that the platform can affect the processes, indicating that it provides a novel environment that has not been investigated before and that the effects of such an environment on many different physical, chemical, or biological processes can be potentially useful for applications in many fields.

  2. Laser plasma soft x-ray microscope with Wolter mirrors for observation of biological specimens in air

    International Nuclear Information System (INIS)

    Hoshino, Masato; Aoki, Sadao

    2006-01-01

    A laser plasma soft X-ray microscope with Wolter mirrors was developed so that specimens could be set in the atmosphere. Silicon nitride membranes 100 nm thick were used as vacuum-tight windows. Using relatively large windows (0.46 x 0.46 mm 2 ), an adequate working distance for samples, which was approximately 1.2 mm, was assured. The endrance of the vacuum-tight window was measured briefly. Dry biological cells could be observed with resolution better than 100 nm. A preliminary observation of wet biological cells was carried out using a wet environmental sample holder which was composed of only two sheets of silicon nitride membrane. An X-ray micrograph of wet red blood cells from a chicken was obtained without apparent effects of radiation damage. The properties of a vacuum-tight window and a wet sample holder are discussed. (author)

  3. Regulation No. 56/2006 Coll. of the Nuclear Regulatory Authority of the Slovak Republic dated as of January 12, 2006 on details concerning requirements for quality system documentation of authorisation holder, as well as details concerning quality requirements for nuclear installations, details concerning quality requirements for classified equipment and details concerning the scope of their approval

    International Nuclear Information System (INIS)

    2006-01-01

    This Regulation provides details of the requirements for quality system documentation holder, details of the quality requirements for nuclear installations, details concerning quality requirements for classified equipment and details of the scope of their approval. This Regulation came into force on March 1, 2006.

  4. Moon-Mars simulation campaign in volcanic Eifel: Remote science support and sample analysis

    Science.gov (United States)

    Offringa, Marloes; Foing, Bernard H.; Kamps, Oscar

    2016-07-01

    assisted by placing the samples onto the sample holder and adjusting test bench settings in order to obtain spectra. After analysis the collected samples were documented and stored by the astronauts, before returning to the base. Points of improvement for the EuroMoonMars2016 analog campaign are the remote control of the computers using an established network between the base and the lander. During following missions the computers should preferably be operated over a larger distance without interference. In the bottom compartment of the lander a rover is stored that in future campaigns could replace astronaut functions by collecting and returning samples, as well as performing adjustments to the analysis test bench by using a remotely controlled robotic arm. Acknowledgements: we thank Dominic Doyle for ESTEC optical lab support, Aidan Cowley (EAC) and Matthias Sperl (DLR) for support discussions, and collaborators from EuroMoonMars Eifel 2015-16 campaign team.

  5. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, Sergei F.; Heilmann, Jens; Heumann, Klaus G. [Johannes Gutenberg-University Mainz (Germany). Institute of Inorganic Chemistry and Analytical Chemistry

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different {sup 34}S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured {sup 34}S/{sup 32}S isotope ratio of the isotope-diluted sample remained constant - a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 {mu}g g{sup -1} ('sulfur-free' premium gasoline) to 10.4 mg g{sup -1} (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 {mu}g g{sup -1} and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level. (orig.)

  6. Resonant ultrasound spectrometer

    Science.gov (United States)

    Migliori, Albert; Visscher, William M.; Fisk, Zachary

    1990-01-01

    An ultrasound resonant spectrometer determines the resonant frequency spectrum of a rectangular parallelepiped sample of a high dissipation material over an expected resonant response frequency range. A sample holder structure grips corners of the sample between piezoelectric drive and receive transducers. Each transducer is mounted on a membrane for only weakly coupling the transducer to the holder structure and operatively contacts a material effective to remove system resonant responses at the transducer from the expected response range. i.e., either a material such as diamond to move the response frequencies above the range or a damping powder to preclude response within the range. A square-law detector amplifier receives the response signal and retransmits the signal on an isolated shield of connecting cabling to remove cabling capacitive effects. The amplifier also provides a substantially frequency independently voltage divider with the receive transducer. The spectrometer is extremely sensitive to enable low amplitude resonance to be detected for use in calculating the elastic constants of the high dissipation sample.

  7. The Effect of Simulated Flash-Heat Pasteurization on Immune Components of Human Milk

    Directory of Open Access Journals (Sweden)

    Brodie Daniels

    2017-02-01

    Full Text Available A pasteurization temperature monitoring system has been designed using FoneAstra, a cellphone-based networked sensing system, to monitor simulated flash-heat (FH pasteurization. This study compared the effect of the FoneAstra FH (F-FH method with the Sterifeed Holder method currently used by human milk banks on human milk immune components (immunoglobulin A (IgA, lactoferrin activity, lysozyme activity, interleukin (IL-8 and IL-10. Donor milk samples (N = 50 were obtained from a human milk bank, and pasteurized. Concentrations of IgA, IL-8, IL-10, lysozyme activity and lactoferrin activity were compared to their controls using the Student’s t-test. Both methods demonstrated no destruction of interleukins. While the Holder method retained all lysozyme activity, the F-FH method only retained 78.4% activity (p < 0.0001, and both methods showed a decrease in lactoferrin activity (71.1% Holder vs. 38.6% F-FH; p < 0.0001 and a decrease in the retention of total IgA (78.9% Holder vs. 25.2% F-FH; p < 0.0001. Despite increased destruction of immune components compared to Holder pasteurization, the benefits of F-FH in terms of its low cost, feasibility, safety and retention of immune components make it a valuable resource in low-income countries for pasteurizing human milk, potentially saving infants’ lives.

  8. Burnout in a sample of primary school teachers in the city of Copiapó

    Directory of Open Access Journals (Sweden)

    Ricardo Jorquera Gutiérrez

    2014-11-01

    Full Text Available The present investigation sought to establish a relationship between burnout and a number of demographic and organizational variables. The sample consisted of 191 primary school teachers of municipal, subsidized and private educational institutions of Copiapó. The Maslach Burnout Inventory (MBI and the Cuestionario de Evaluación del Sindrome de Quemarse en el Trabajo (CESQT were used as tools to gather information from burnout levels presented by teachers. Two of them demonstrated an adequate reliability and concurrent validity. The results show a statistically significant relationship between absenteeism variable and all dimensions of burnout as measured by both instruments. No statistically significant differences between variables MBI and CESQT compared by sex, type of contract and income level were observed. When comparing the different dimensions of burnout by type of holder, statistically significant differences were detected in all of them. The results favor the private schools, showing the worst results in municipal schools. Alongside this, a negative correlation between levels of emotional exhaustion and psychological wear developed by teams of teachers and the results of the tests SIMCE [Sistema de Medición de la Calidad de la Educación] for second and fourth grade is observed.

  9. The preventive Control of White Root Rot Disease in Small Holder Rubber Plantation Using Botanical, Biological and Chemical Agents

    Directory of Open Access Journals (Sweden)

    Joko Prasetyo

    2014-03-01

    Full Text Available The preventive control of white root rot disease in small holder plantation using botanical, biological, and chemical agents. A field and laboratory experiment were conducted from June 2008 to December 2009 in Panumangan, Tulang Bawang - Lampung. The  field experiment was intended to evaluate the effect of  botanical plants (Alpinia galanga, Sansiviera auranthii, and Marantha arundinacea, biological agents (organic matter and Trichoderma spp., and chemical agents (lime and natural sulphur on the incidence of white root rot disease and population of some soil microbes. The laboratory experiment was conducted  to observe the mechanism of botanical agents  in controlling white root rot disease. In the field experiment, the treatments were applied  in the experimental plot with cassava plant infection as the indicator. The variables  examined were the incidence of  white root rot and population of soil microbes. In the laboratory experiment, culture of R. microporus was grown in PDA containing root exudate of the antagonistic plant (botanical agent. The variable examined was colony diameter of R. microporus growing in the PDA plates. The results of the  field experiment  showed that planting of the botanical agents, and application of Trichoderma spp., as well as natural sulphur, decreased the incidence of white root rot disease. The effectiveness of M. arundinacea and Trichoderma spp. was comparable to natural  sulphur. The laboratory experiment showed only root exudate of  A. galanga and  S. auranthii that were significantly inhibit the growth of R. microporus.

  10. A Tale of Two Majors: Explaining the Gender Gap in STEM Employment among Computer Science and Engineering Degree Holders

    Directory of Open Access Journals (Sweden)

    Sharon Sassler

    2017-07-01

    Full Text Available We examine factors contributing to the gender gap in employment in science, technology, engineering, and math (STEM among men and women with bachelor’s degrees in computer science and engineering, the two largest and most male-dominated STEM fields. Data come from the National Science Foundation’s (NSF Scientists and Engineers Statistical Data System (SESTAT from 1995 to 2008. Different factors are associated with persistence in STEM jobs among computer science and engineering degree holders. Conditional on receiving a degree in computer science, women are 14 percentage points less likely to work in STEM than their male counterparts. Controlling for demographic and family characteristics did little to change this gender gap. Women with degrees in engineering are approximately 8 percentage points less likely to work in STEM than men, although about half of this gap is explained by observed differences between men and women. We document a widening gender gap in STEM employment in computer science, but this gender gap narrows across college cohorts among those with degrees in engineering. Among recent computer science graduates, the gender gap in STEM employment for white, Hispanic, and black women relative to white men is even larger than for older graduates. Gender and race gaps in STEM employment for recent cohorts of engineering graduates are generally small, though younger Asian women and men no longer have an employment advantage relative to white men. Our results suggest that a one-size-fits-all approach to increasing women’s representation in the most male-dominated STEM fields may not work.

  11. Integrated sampling and analysis unit for the determination of sexual pheromones in environmental air using fabric phase sorptive extraction and headspace-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Alcudia-León, M Carmen; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel; Kabir, Abuzar; Furton, Kenneth G

    2017-03-10

    This article presents a novel unit that integrates for the first time air sampling and preconcentration based on the use of fabric phase sorptive extraction principles. The determination of Tuta absoluta sexual pheromone traces in environmental air has been selected as analytical problem. For this aim, a novel laboratory-built unit made up of commercial brass elements as holder of the sol-gel coated fabric extracting phase has been designed and optimized. The performance of the integrated unit was evaluated analyzing environmental air sampled in tomato crops. The unit can work under sampling and analysis mode which eliminates any need for sorptive phase manipulation prior to instrumental analysis. In the sampling mode, the unit can be connected to a sampling pump to pass the air through the sorptive phase at a controlled flow-rate. In the analysis mode, it is placed in the gas chromatograph autosampler without any instrumental modification. It also diminishes the risk of cross contamination between sampling and analysis. The performance of the new unit has been evaluated using the main components of the sexual pheromone of Tuta absoluta [(3E,8Z,11Z)-tetradecatrien-1-yl acetate and (3E,8Z)-tetradecadien-1-yl acetate] as model analytes. The limits of detection for both compounds resulted to be 1.6μg and 0.8μg, respectively, while the precision (expressed as relative standard deviation) was better than 3.7%. Finally, the unit has been deployed in the field to analyze a number of real life samples, some of them were found positive. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Fourth-generation plasma immersion ion implantation and deposition facility for hybrid surface modification layer fabrication

    International Nuclear Information System (INIS)

    Wang Langping; Huang Lei; Xie Zhiwen; Wang Xiaofeng; Tang Baoyin

    2008-01-01

    The fourth-generation plasma immersion ion implantation and deposition (PIIID) facility for hybrid and batch treatment was built in our laboratory recently. Comparing with our previous PIIID facilities, several novel designs are utilized. Two multicathode pulsed cathodic arc plasma sources are fixed on the chamber wall symmetrically, which can increase the steady working time from 6 h (the single cathode source in our previous facilities) to about 18 h. Meanwhile, the inner diameter of the pulsed cathodic arc plasma source is increased from the previous 80 to 209 mm, thus, large area metal plasma can be obtained by the source. Instead of the simple sample holder in our previous facility, a complex revolution-rotation sample holder composed of 24 shafts, which can rotate around its axis and adjust its position through revolving around the center axis of the vacuum chamber, is fixed in the center of the vacuum chamber. In addition, one magnetron sputtering source is set on the chamber wall instead of the top cover in the previous facility. Because of the above characteristic, the PIIID hybrid process involving ion implantation, vacuum arc, and magnetron sputtering deposition can be acquired without breaking vacuum. In addition, the PIIID batch treatment of cylinderlike components can be finished by installing these components on the rotating shafts on the sample holder

  13. Fourth-generation plasma immersion ion implantation and deposition facility for hybrid surface modification layer fabrication.

    Science.gov (United States)

    Wang, Langping; Huang, Lei; Xie, Zhiwen; Wang, Xiaofeng; Tang, Baoyin

    2008-02-01

    The fourth-generation plasma immersion ion implantation and deposition (PIIID) facility for hybrid and batch treatment was built in our laboratory recently. Comparing with our previous PIIID facilities, several novel designs are utilized. Two multicathode pulsed cathodic arc plasma sources are fixed on the chamber wall symmetrically, which can increase the steady working time from 6 h (the single cathode source in our previous facilities) to about 18 h. Meanwhile, the inner diameter of the pulsed cathodic arc plasma source is increased from the previous 80 to 209 mm, thus, large area metal plasma can be obtained by the source. Instead of the simple sample holder in our previous facility, a complex revolution-rotation sample holder composed of 24 shafts, which can rotate around its axis and adjust its position through revolving around the center axis of the vacuum chamber, is fixed in the center of the vacuum chamber. In addition, one magnetron sputtering source is set on the chamber wall instead of the top cover in the previous facility. Because of the above characteristic, the PIIID hybrid process involving ion implantation, vacuum arc, and magnetron sputtering deposition can be acquired without breaking vacuum. In addition, the PIIID batch treatment of cylinderlike components can be finished by installing these components on the rotating shafts on the sample holder.

  14. A microcontroller-based microwave free-space measurement system for permittivity determination of lossy liquid materials.

    Science.gov (United States)

    Hasar, U C

    2009-05-01

    A microcontroller-based noncontact and nondestructive microwave free-space measurement system for real-time and dynamic determination of complex permittivity of lossy liquid materials has been proposed. The system is comprised of two main sections--microwave and electronic. While the microwave section provides for measuring only the amplitudes of reflection coefficients, the electronic section processes these data and determines the complex permittivity using a general purpose microcontroller. The proposed method eliminates elaborate liquid sample holder preparation and only requires microwave components to perform reflection measurements from one side of the holder. In addition, it explicitly determines the permittivity of lossy liquid samples from reflection measurements at different frequencies without any knowledge on sample thickness. In order to reduce systematic errors in the system, we propose a simple calibration technique, which employs simple and readily available standards. The measurement system can be a good candidate for industrial-based applications.

  15. 40 CFR 60.50Da - Compliance determination procedures and methods.

    Science.gov (United States)

    2010-07-01

    ... probe and filter holder heating system in the sampling train may be set to provide an average gas... correction factor, integrated or grab sampling and analysis procedures of Method 3B of appendix A of this... fuel oil, etc.), coal pulverizers, and bottom and fly ash interactions. This determination is optional...

  16. JUST Vol. 29 No. 1 April 2009

    African Journals Online (AJOL)

    Prince

    2009-04-01

    , this research investigates the impact of stool land revenue in ... The 'allodial' title holders are customary trus- tees only .... to collect quantitative information from a sample .... the fiduciary position of chiefs and therefore has a.

  17. Automatic cross-sectioning and monitoring system locates defects in electronic devices

    Science.gov (United States)

    Jacobs, G.; Slaughter, B.

    1971-01-01

    System consists of motorized grinding and lapping apparatus, sample holder, and electronic control circuit. Low power microscope examines device to pinpoint location of circuit defect, and monitor displays output signal when defect is located exactly.

  18. 7 CFR Appendix K to Subpart E of... - Regulations for Loan Guarantees for Disaster Assistance For Rural Business Enterprises

    Science.gov (United States)

    2010-01-01

    ... appropriate amount due the Holder(s). Any discrepancy between the amount claimed by the Holder(s) and the...-354 will pay the Holder only the amounts due the Holder, FmHA or its successor agency under Public Law... pay an estimated loss settlement to the Lender provided the lender applies such amount due to the...

  19. Critical current measurements of high-temperature superconducting short samples at a wide range of temperatures and magnetic fields

    Science.gov (United States)

    Ma, Hongjun; Liu, Huajun; Liu, Fang; Zhang, Huahui; Ci, Lu; Shi, Yi; Lei, Lei

    2018-01-01

    High-Temperature Superconductors (HTS) are potential materials for high-field magnets, low-loss transmission cables, and Superconducting Magnetic Energy Storage (SMES) due to their high upper critical magnetic field (Hc2) and critical temperature (Tc). The critical current (Ic) of HTS, which is one of the most important parameters for superconductor application, depends strongly on the magnetic fields and temperatures. A new Ic measurement system that can carry out accurate Ic measurement for HTS short samples with various temperatures (4.2-80 K), magnetic fields (0-14 T), and angles of the magnetic field (0°-90°) has been developed. The Ic measurement system mainly consists of a measurement holder, temperature-control system, background magnet, test cryostat, data acquisition system, and DC power supply. The accuracy of temperature control is better than ±0.1 K over the 20-80 K range and ±0.05 K when measured below 20 K. The maximum current is over 1000 A with a measurement uncertainty of 1%. The system had been successfully used for YBa2Cu3O7-x(YBCO) tapes Ic determination with different temperatures and magnetic fields.

  20. Critical current measurements of high-temperature superconducting short samples at a wide range of temperatures and magnetic fields.

    Science.gov (United States)

    Ma, Hongjun; Liu, Huajun; Liu, Fang; Zhang, Huahui; Ci, Lu; Shi, Yi; Lei, Lei

    2018-01-01

    High-Temperature Superconductors (HTS) are potential materials for high-field magnets, low-loss transmission cables, and Superconducting Magnetic Energy Storage (SMES) due to their high upper critical magnetic field (H c2 ) and critical temperature (T c ). The critical current (I c ) of HTS, which is one of the most important parameters for superconductor application, depends strongly on the magnetic fields and temperatures. A new I c measurement system that can carry out accurate I c measurement for HTS short samples with various temperatures (4.2-80 K), magnetic fields (0-14 T), and angles of the magnetic field (0°-90°) has been developed. The I c measurement system mainly consists of a measurement holder, temperature-control system, background magnet, test cryostat, data acquisition system, and DC power supply. The accuracy of temperature control is better than ±0.1 K over the 20-80 K range and ±0.05 K when measured below 20 K. The maximum current is over 1000 A with a measurement uncertainty of 1%. The system had been successfully used for YBa 2 Cu 3 O 7-x (YBCO) tapes I c determination with different temperatures and magnetic fields.

  1. Fakinle et al (11)

    African Journals Online (AJOL)

    DELL

    management issues; there is however a concern about air emissions from the ... poses risks to humans and animals through ... Nigeria have focused on cement industries. (Adejumo et al. ... based MCA which controls the sample holder and.

  2. 40 CFR Table 5 of Subpart Aaaa to... - Requirements for Stack Tests

    Science.gov (United States)

    2010-07-01

    ... the municipal waste combustion unit is operating at full load. 2. Metals: Cadmium Method 1 Method 29 a... and filter holder heating systems in the sample train must be set to provide a gas temperature no...

  3. Realisation and instrumentation of high current power station for superconducting cables testing

    International Nuclear Information System (INIS)

    Regnaud, S.

    2000-05-01

    This report deals with the designing of a high current station able to test electric properties of superconductors. This test station will be used for testing the superconducting wires of large hadron collider detectors in CERN. The high current test station will have to generate high intensity continuous current in a magnetic field of 0 to 5 tesla and in temperature conditions of 4.2 K. The length of wire samples submitted to the uniform magnetic field is 300 mm and the installation is fitted with equipment able to measure the magnetic field perpendicular to either faces of the wire. The peculiarity of this station is to use a superconducting transformer in order to generate the high current. The first part of this work recalls important notions concerning superconductivity. The second part presents the high current station by describing the superconducting transformer and the sample-holder. We have studied the designing of a transformer able to yield a secondary current whose intensity reaches 100 kA, such intensity generates powerful electromagnetic forces (566 kN/m) in case of defect, so the sample-holder has to be carefully design to bear them. The third part presents the cryogenic component of the station, the instrumentation of the sample-holder and the method used to measure secondary currents. In the last part we present the performance of a prototype transformer, this prototype is able to deliver a 22 kA secondary current for a 160 A primary current, the uncertainty on the measured value of the secondary current is about 3%

  4. Atmospheric scanning electron microscope for correlative microscopy.

    Science.gov (United States)

    Morrison, Ian E G; Dennison, Clare L; Nishiyama, Hidetoshi; Suga, Mitsuo; Sato, Chikara; Yarwood, Andrew; O'Toole, Peter J

    2012-01-01

    The JEOL ClairScope is the first truly correlative scanning electron and optical microscope. An inverted scanning electron microscope (SEM) column allows electron images of wet samples to be obtained in ambient conditions in a biological culture dish, via a silicon nitride film window in the base. A standard inverted optical microscope positioned above the dish holder can be used to take reflected light and epifluorescence images of the same sample, under atmospheric conditions that permit biochemical modifications. For SEM, the open dish allows successive staining operations to be performed without moving the holder. The standard optical color camera used for fluorescence imaging can be exchanged for a high-sensitivity monochrome camera to detect low-intensity fluorescence signals, and also cathodoluminescence emission from nanophosphor particles. If these particles are applied to the sample at a suitable density, they can greatly assist the task of perfecting the correlation between the optical and electron images. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. In situ light spectroscopy in the environmental transmission electron microscope (ETEM)

    DEFF Research Database (Denmark)

    Cavalca, Filippo; Langhammer, C.; Pedersen, Thomas

    2012-01-01

    the LSPR signal coming from the whole specimen, providing information complementary to the TEM analysis. During any ETEM experiment the electron beam effect on the sample is a difficult issue to address and rule out. In addition, if a reaction has to be followed in situ in the ETEM, the information...... is often recorded on a limited portion of the sample. Being able to probe the sample with INPS and ETEM at the same time allows parallel investigation at the local and macro scale, as well as aids the assessment of beam effects. A dedicated custom TEM specimen holder containing two optical fibers, five...... electrical contacts, a fixed miniaturized optical bench for light handling and a heating element (Fig. 1) has been designed. A system of pre-aligned mirrors and a MEMS heater are implemented in the holder. The system is primarily designed for use in combination with LSPR spectroscopy, but it is flexible...

  6. Tomographic Imaging of Water Injection and Withdrawal in PEMFC Gas Diffusion Layers

    Energy Technology Data Exchange (ETDEWEB)

    McGill U; Gostick, J. T.; Gunterman, H. P.; Weber, A. Z.; Newman, J. S.; Kienitz, B. L.; MacDowell, A. A.

    2010-06-25

    X-ray computed tomography was used to visualize the water configurations inside gas diffusion layers for various applied capillary pressures, corresponding to both water invasion and withdrawal. A specialized sample holder was developed to allow capillary pressure control on the small-scale samples required. Tests were performed on GDL specimens with and without hydrophobic treatments.

  7. Assessment of goat breed improvement through distribution of beetal bucks in rainfed pothwar, Punjab

    International Nuclear Information System (INIS)

    Akmal, N.; Shah, H.; Niazi, N.

    2010-01-01

    The present paper is based on the assessment of goat breed improvement intervention through supply of 65 Beetal bucks in rainfed Pothwar. To judge short term impact and assessment, a survey was carried out of both buck holder and non-holder beneficiaries in six project tehsils, after one year of buck distribution. Data were collected from a sample of 38 buck holders and 31 beneficiary farmers using a structured pretested questionnaire. The main influencing factor in keeping bucks was goat breed improvement. All the sample respondents were convinced of the benefits of crosses with Beetal buck and reported that the offsprings Beetal were of higher body weight (40% higher), good looking and well built. Regarding the suitability of Beetal with fodder and forage in the area, majority of the farmers (73%) considered it more suitable. There was a price difference of Rs. 1277 for male kids and Rs. 697 for female kids of the same age than the kids from local buck crosses. The farmers believed that the price difference was not only due to the higher weight but a better look and better structure of the Beetal goat. Farming community showed keen interest in using this intervention on a regular basis. (author)

  8. Political consciousness and political action of industrial workers in Ghana : a case study of VALCO workers at Tema

    NARCIS (Netherlands)

    Konings, P.J.J.

    1978-01-01

    What is the political consciousness of Ghanaian workers in large-scale foreign and state enterprises and what action have they engaged in? The present study, based on fieldwork in Ghana in 1975, attempts to answer these questions with regard to answer these questions with regard to industrial

  9. Evaluation of energy deposition by 153Sm in small samples

    International Nuclear Information System (INIS)

    Cury, M.I.C.; Siqueira, P.T.D.; Yoriyaz, H.; Coelho, P.R.P.; Da Silva, M.A.; Okazaki, K.

    2002-01-01

    V/Bq.s that represents 79 % of available energy. The axial dose distribution mapping shows also a great difference between gamma radiation and charged radiation deposition patterns. While the gamma radiation energy deposition is clearly sensitive to the holder shape, charged radiation shows this dependence only in the vicinity of the sample itself. However, as the charged radiation accounts for almost all the energy deposited in the sample, the dose distribution over the sample can be regarded as homogeneous, although its value be dependent of the amount of 153 Sm solution added. Conclusion: This work shows that an infinite medium approach to estimate the amount of deposited energy is not valid to systems of the order of mm-cm. It supplies a way to provide a precise value for the absorbed dose and also its gradient distribution

  10. Unusual Complication of Suprapubic Cystostomy in a Male Patient with Tetraplegia: Traction on Foley Catheter Leading to Extrusion of Foley Balloon from Urinary Bladder and Suprapubic Urinary Fistula – Importance of Securely Anchoring Suprapubic Catheter with Adhesive Tape or BioDerm Tube Holder

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2007-01-01

    Full Text Available Suprapubic cystostomy is recommended to patients with neuropathic bladder to prevent complications of long-term urethral catheter drainage. We present a 50-year-old male patient with tetraplegia who had long-term urethral catheter drainage. Following flexible cystoscopy, he developed a urine leak from the right side of the scrotum. Suprapubic cystostomy was performed. After suprapubic cystostomy, the urinary fistula healed completely. A follow-up cystourethrogram confirmed an intact urethra with no leak of contrast. Six weeks later, this patient presented with a hole below the suprapubic cystostomy through which a small amount of urine was leaking. A keyhole dressing had been applied around the suprapubic catheter and the catheter was hanging loosely, thus permitting traction on the catheter, especially when the urine bag was full. Computerised tomography of the pelvis showed extrusion of the Foley balloon from the urinary bladder, but the tip of the catheter was still located within the bladder. The extruded catheter was removed and a Foley catheter was inserted, ensuring that the balloon was inflated within the urinary bladder. The suprapubic catheter was secured firmly to the anterior abdominal wall with a BioDerm Tube Holder, thus preventing any traction on the catheter or Foley balloon. The urine leak through the hole below the suprapubic cystostomy stopped and the sinus healed. This case illustrates the need to anchor the suprapubic catheter securely to the anterior abdominal wall with adhesive tape or BioDerm Tube Holder to prevent traction and consequent displacement of the catheter or Foley balloon.

  11. Degradation of Carbon Fiber Reinforced Polymer and Graphite by Laser Heating

    Science.gov (United States)

    2016-08-01

    Education and Training Command In Partial Fulfillment of the Requirements for the Degree of Doctor of Philosophy Nicholas C. Herr, BS, MS Captain...ensuring good thermal contact between the sample and its holder (by using sample powders, pellets, or thin films ). The sample temperature is also...carbon nanotube and carbon-containing thin- film manufacturing [82–84] as well as cleaning graphite surfaces in experimental fusion reactors [83

  12. Combinatorial Production and Processing of Oxide Nanopowders for Transparent, Ceramic Lasers

    Science.gov (United States)

    2007-06-01

    characterized by XRD, using a Rigaku Rotating Anode Goniometer (Rigaku Denki Co. Ltd., Tokyo, Japan ), Powder samples for the Rigaku diffractometer were...NJ) were ground using an alumina mortar and pestle , with 1.0 wt% of the sample to be analyzed and packed firmly in the sample holder, leveled off at...acquired using a JEOL 4000EX (Osaka, 99+/o] were purchased from Alfa Aesar and used as received. Japan ) electron microscope operated at 400 kV. Samples

  13. Multiplane optical microscope

    Science.gov (United States)

    Li, Tongcang; Ota, Sadao; Kim, Jeongmin; Wang, Yuan; Zhang, Xiang

    2017-11-21

    This disclosure provides systems, methods, and apparatus related to optical microscopy. In one aspect, an apparatus includes a sample holder, a first objective lens, a plurality of optical components, a second objective lens, and a mirror. The apparatus may directly image a cross-section of a sample oblique to or parallel to the optical axis of the first objective lens, without scanning.

  14. A bar-code reader for an alpha-beta automatic counting system - FAG

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, S; Shemesh, Y; Ankry, N; Assido, H; German, U; Peled, O [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    A bar-code laser system for sample number reading was integrated into the FAG Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. Installation of the bar-code reader system required several modifications: Mechanical changes in the automatic sample changer, design and production of new sample holders, modification of the sample planchettes, changes in the electronic system, update of the operating software of the system (authors).

  15. A bar-code reader for an alpha-beta automatic counting system - FAG

    International Nuclear Information System (INIS)

    Levinson, S.; Shemesh, Y.; Ankry, N.; Assido, H.; German, U.; Peled, O.

    1996-01-01

    A bar-code laser system for sample number reading was integrated into the FAG Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. Installation of the bar-code reader system required several modifications: Mechanical changes in the automatic sample changer, design and production of new sample holders, modification of the sample planchettes, changes in the electronic system, update of the operating software of the system (authors)

  16. Development of INAA automation at CARR

    International Nuclear Information System (INIS)

    Yao Yonggang; Xiao Caijin; Hua Long; Jin Xiangchun; Wang Xinghua; Li Jue; Cao Lei; Wang Pingsheng; Ni Bangfa

    2016-01-01

    A new INAA (instrumental neutron activation analysis) automatic measurement system has been established at China advanced research reactor. Three HPGe spectrometers can be working simultaneously at 24 h a day. The sample rabbit contains an RFID (radio frequency identification) tag which is used for identifying and/or tracing the sample route or location. The automation system controlled by software Kingview6.55 and programmable logic controller is mainly composed of four parts, sample counting system, sample driving system, samples holder and sample exchanger. (author)

  17. Micro/nano-mechanical test system employing tensile test holder with push-to-pull transformer

    Science.gov (United States)

    Oh, Yunje; Cyrankowski, Edward; Shan, Zhiwei; Asif, Syed Amanula Syed

    2013-05-07

    A micromachined or microelectromechanical system (MEMS) based push-to-pull mechanical transformer for tensile testing of micro-to-nanometer scale material samples including a first structure and a second structure. The second structure is coupled to the first structure by at least one flexible element that enables the second structure to be moveable relative to the first structure, wherein the second structure is disposed relative to the first structure so as to form a pulling gap between the first and second structures such that when an external pushing force is applied to and pushes the second structure in a tensile extension direction a width of the pulling gap increases so as to apply a tensile force to a test sample mounted across the pulling gap between a first sample mounting area on the first structure and a second sample mounting area on the second structure.

  18. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Naes, Benjamin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Olsen, Khris B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chouyyok, Wilaiwan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willingham, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Spigner, Angel C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO2F2 and UO2(NO3)2, U3O8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO2F2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.

  19. Validation of coupled neutronic / thermal-hydraulic codes for VVER reactors. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Mittag, S.; Grundmann, U.; Kliem, S.; Kozmenkov, Y.; Rindelhardt, U.; Rohde, U.; Weiss, F.-P.; Langenbuch, S.; Krzykacz-Hausmann, B.; Schmidt, K.-D.; Vanttola, T.; Haemaelaeinen, A.; Kaloinen, E.; Kereszturi, A.; Hegyi, G.; Panka, I.; Hadek, J.; Strmensky, C.; Darilek, P.; Petkov, P.; Stefanova, S.; Kuchin, A.; Khalimonchuk, V.; Hlbocky, P.; Sico, D.; Danilin, S.; Ionov, V.; Nikonov, S.; Powney, D.

    2004-08-01

    In recent years, the simulation methods for the safety analysis of nuclear power plants have been continuously improved to perform realistic calculations. Therefore in VALCO work package 2 (WP 2), the usual application of coupled neutron-kinetic / thermal-hydraulic codes to VVER has been supplemented by systematic uncertainty and sensitivity analyses. A comprehensive uncertainty analysis has been carried out. The GRS uncertainty and sensitivity method based on the statistical code package SUSA was applied to the two transients studied earlier in SRR-1/95: A load drop of one turbo-generator in Loviisa-1 (VVER-440), and a switch-off of one feed water pump in Balakovo-4 (VVER-1000). The main steps of these analyses and the results obtained by applying different coupled code systems (SMABRE - HEXTRAN, ATHLET - DYN3D, ATHLET - KIKO3D, ATHLET - BIPR-8) are described in this report. The application of this method is only based on variations of input parameter values. No internal code adjustments are needed. An essential result of the analysis using the GRS SUSA methodology is the identification of the input parameters, such as the secondary-circuit pressure, the control-assembly position (as a function of time), and the control-assembly efficiency, that most sensitively affect safety-relevant output parameters, like reactor power, coolant heat-up, and primary pressure. Uncertainty bands for these output parameters have been derived. The variation of potentially uncertain input parameter values as a consequence of uncertain knowledge can activate system actions causing quite different transient evolutions. This gives indications about possible plant conditions that might be reached from the initiating event assuming only small disturbances. In this way, the uncertainty and sensitivity analysis reveals the spectrum of possible transient evolutions. Deviations of SRR-1/95 coupled code calculations from measurements also led to the objective to separate neutron kinetics from

  20. Effect of Boundary Condition on the Shear Behaviour of Rock Joints in the Direct Shear Test

    Science.gov (United States)

    Bahaaddini, M.

    2017-05-01

    The common method for determination of the mechanical properties of the rock joints is the direct shear test. This paper aims to study the effect of boundary condition on the results of direct shear tests. Experimental studies undertaken in this research showed that the peak shear strength is mostly overestimated. This problem is more pronounced for steep asperities and under high normal stresses. Investigation of the failure mode of these samples showed that tensile cracks are generated at the boundary of sample close to the specimen holders and propagated inside the intact materials. In order to discover the reason of observed failure mechanism in experiments, the direct shear test was simulated using PFC2D. Results of numerical models showed that the gap zone size between the upper and lower specimen holders has a significant effect on the shear mechanism. For the high gap size, stresses concentrate at the vicinity of the tips of specimen holders and result in generation and propagation of tensile cracks inside the intact material. However, by reducing the gap size, stresses are concentrated on asperities, and damage of specimen at its boundary is not observed. Results of this paper show that understanding the shear mechanism of rock joints is an essential step prior to interpreting the results of direct shear tests.

  1. Sample size estimation and sampling techniques for selecting a representative sample

    Directory of Open Access Journals (Sweden)

    Aamir Omair

    2014-01-01

    Full Text Available Introduction: The purpose of this article is to provide a general understanding of the concepts of sampling as applied to health-related research. Sample Size Estimation: It is important to select a representative sample in quantitative research in order to be able to generalize the results to the target population. The sample should be of the required sample size and must be selected using an appropriate probability sampling technique. There are many hidden biases which can adversely affect the outcome of the study. Important factors to consider for estimating the sample size include the size of the study population, confidence level, expected proportion of the outcome variable (for categorical variables/standard deviation of the outcome variable (for numerical variables, and the required precision (margin of accuracy from the study. The more the precision required, the greater is the required sample size. Sampling Techniques: The probability sampling techniques applied for health related research include simple random sampling, systematic random sampling, stratified random sampling, cluster sampling, and multistage sampling. These are more recommended than the nonprobability sampling techniques, because the results of the study can be generalized to the target population.

  2. A setup for measuring the Seebeck coefficient and the electrical resistivity of bulk thermoelectric materials

    Science.gov (United States)

    Fu, Qiang; Xiong, Yucheng; Zhang, Wenhua; Xu, Dongyan

    2017-09-01

    This paper presents a setup for measuring the Seebeck coefficient and the electrical resistivity of bulk thermoelectric materials. The sample holder was designed to have a compact structure and can be directly mounted in a standard cryostat system for temperature-dependent measurements. For the Seebeck coefficient measurement, a thin bar-shaped sample is mounted bridging two copper bases; and two ceramic heaters are used to generate a temperature gradient along the sample. Two type T thermocouples are used to determine both temperature and voltage differences between two widely separated points on the sample. The thermocouple junction is flattened into a disk and pressed onto the sample surface by using a spring load. The flexible fixation method we adopted not only simplifies the sample mounting process but also prevents thermal contact deterioration due to the mismatch of thermal expansion coefficients between the sample and other parts. With certain modifications, the sample holder can also be used for four-probe electrical resistivity measurements. High temperature measurements are essential for thermoelectric power generation. The experimental system we developed is capable of measuring the Seebeck coefficient and the electrical resistivity of bulk thermoelectric materials in a wide temperature range from 80 to 500 K, which can be further extended to even higher temperatures. Measurements on two standard materials, constantan and nickel, confirmed the accuracy and the reliability of the system.

  3. The Fate of Malathion on Copper and Iron Piping Within a Water Distribution System

    Science.gov (United States)

    2015-03-26

    application in biological, polymers and plastics , explosive, inorganic compounds as well as metal and alloy research (Dodd & Tonge, 1987). There are...submerged in a dielectric fluid [i.e. water] prior to the EDM sending an electrically charged brass wire over the sample. The wire disintegrated the...period, the coupon samples were removed from the glass vial, placed on a plastic sample holder, and allowed to dry in the desiccator for a four-hour

  4. Inactivation of Mycobacterium paratuberculosis in cows' milk at pasteurization temperatures.

    Science.gov (United States)

    Grant, I R; Ball, H J; Neill, S D; Rowe, M T

    1996-01-01

    The thermal inactivation of 11 strains of Mycobacterium paratuberculosis at pasteurization temperatures was investigated. Cows' milk inoculated with M. paratuberculosis at two levels (10(7) and 10(4) CFU/ml) was pasteurized in the laboratory by (i) a standard holder method (63.5 degrees C for 30 min) and (ii) a high-temperature, short-time (HTST) method (71.7 degrees C for 15 s). Additional heating times of 5, 10, 15, 20, and 40 min at 63.5 degrees C were included to enable the construction of a thermal death curve for the organism. Viability after pasteurization was assessed by culture on Herrold's egg yolk medium containing mycobactin J (HEYM) and in BACTEC Middlebrook 12B radiometric medium supplemented with mycobactin J and sterile egg yolk emulsion. Confirmation of acid-fast survivors of pasteurization as viable M. paratuberculosis cells was achieved by subculture on HEYM to indicate viability coupled with PCR using M. paratuberculosis-specific 1S900 primers. When milk was initially inoculated with 10(6) to 10(7) CFU of M. paratuberculosis per ml, M. paratuberculosis cells were isolated from 27 of 28 (96%) and 29 of 34 (85%) pasteurized milk samples heat treated by the holder and HTST methods, respectively. Correspondingly, when 10(3) to 10(4) CFU of M. paratuberculosis per ml of milk were present before heat treatment, M. paratuberculosis cells were isolated from 14 of 28 (50%) and 19 of 33 (58%) pasteurized milk samples heat treated by the holder and HTST methods, respectively. The thermal death curve for M. paratuberculosis was concave in shape, exhibiting a rapid initial death rate followed by significant "tailing." Results indicate that when large numbers of M. paratuberculosis cells are present in milk, the organism may not be completely inactivated by heat treatments simulating holder and HTST pasteurization under laboratory conditions. PMID:8593064

  5. A mini-sampler for welding aerosol mounted in close vicinity of the mouth/nose

    International Nuclear Information System (INIS)

    Liden, Goeran; Surakka, Jouni

    2009-01-01

    A small personal aerosol mini-sampler to be used inside modern welding visors has been developed. The main object of the mini-sampler has been to sample manganese. The sampler is based on commercially available 13 mm filter holders but modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini-sampler is 0,75 l/min. The sampler is to be worn mounted on a headset, modified from professional microphone headsets. The headset mounting arrangement was accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler depends on the coarseness of the sampled aerosol. At the lowest concentration ratio of the open-face 25 mm filter holder to the IOM sampler equal to 0,65, the bias of the mini sampler is approximately -26% versus the IOM. The RMS sampling bias of the mini sampler versus the IOM sampler for manganese is -4,6%. The inhalable fraction of welding aerosol mass consists only of 25-55% of welding fume. The rest of the mass is made up of spatter particles and grinding particles. For manganese generally more than 65% is found in the fume.

  6. 76 FR 61668 - Application(s) for Duty-Free Entry of Scientific Instruments

    Science.gov (United States)

    2011-10-05

    ... of biological assemblies composed of protein, nucleic acids, lipid and detergent. The studies will... research. A 120kV electron microscope with an anticontaminator and specimen holder suitable for imaging biological samples at liquid nitrogen temperatures is required for the research. Justification for Duty-Free...

  7. Simultaneous measurement of hysteresis in capillary pressure and electric permittivity for multiphase flow through porous media

    NARCIS (Netherlands)

    Plug, W.J.; Slob, E.C.; Bruining, J.; Moreno Tirado, L.M.

    2007-01-01

    We present a tool that simultaneously measures the complex permittivity and the capillary pressure characteristics for multiphase flow. The sample holder is a parallel plate capacitor. A precision component analyzer is used to measure the impedance amplitude and phase angle as a function of

  8. Microwave moisture meter for in-shell almonds.

    Science.gov (United States)

    Determining almond kernel moisture content while still in the shell is important for both almond growers and processors. A dielectric method was developed for almond kernel moisture determination from dielectric measurements on in-shell almonds at a single microwave frequency. A sample holder was fi...

  9. In-situ straining and time-resolved electron tomography data acquisition in a transmission electron microscope.

    Science.gov (United States)

    Hata, S; Miyazaki, S; Gondo, T; Kawamoto, K; Horii, N; Sato, K; Furukawa, H; Kudo, H; Miyazaki, H; Murayama, M

    2017-04-01

    This paper reports the preliminary results of a new in-situ three-dimensional (3D) imaging system for observing plastic deformation behavior in a transmission electron microscope (TEM) as a directly relevant development of the recently reported straining-and-tomography holder [Sato K et al. (2015) Development of a novel straining holder for transmission electron microscopy compatible with single tilt-axis electron tomography. Microsc. 64: 369-375]. We designed an integrated system using the holder and newly developed straining and image-acquisition software and then developed an experimental procedure for in-situ straining and time-resolved electron tomography (ET) data acquisition. The software for image acquisition and 3D visualization was developed based on the commercially available ET software TEMographyTM. We achieved time-resolved 3D visualization of nanometer-scale plastic deformation behavior in a Pb-Sn alloy sample, thus demonstrating the capability of this system for potential applications in materials science. © The Author 2016. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Fission track dating method: I. Study of neutron flux uniformity in some irradiation positions of IEA-R1 reactor

    International Nuclear Information System (INIS)

    Osorio, A.M.; Hadler, J.C.; Iunes, P.J.; Paulo, S.R. de

    1993-06-01

    In order to use the fission track dating method the flux gradient was verified within the sample holder, in some irradiation positions of the IEA-R1 reactor at IPEN/CNEN, Sao Paulo. The fission track dating method considers only the thermal neutron fission tracks, to subtract the other contributions sample irradiations with a cadmium cover was performed. The neutron flux cadmium influence was studied. (author)

  11. X-ray table

    International Nuclear Information System (INIS)

    Craig, J.R.; Otto, G.W.

    1980-01-01

    An X-ray radiographic or fluoroscopic table is described which includes a film holder with a frame attached to a cable running over end pulleys for positioning the holder longitudinally as desired under the table top. The holder has a front opening to receive a cassette-supporting tray which can be slid out on tracks to change the cassette. A reed switch on the frame is opened by a permanent magnet on the tray only when the tray is half-way out. When the switch is closed, an electromagnet locks the pulley and the holder in place. The holder is thus automatically locked in place not only during exposure (tray in) but when the tray is out for changing the cassette. To re-position the holder, the operator pulls the tray half-out and, using the tray itself, pushes the holder along the table, the holder being counterbalanced by a weight. (author)

  12. MORPHOLOGICAL ASPECTS OF HUMAN LENS CAPSULES - A COMPARATIVE LM, SEM AND TEM EXAMINATION

    NARCIS (Netherlands)

    JONGEBLOED, WL; KALICHARAN, D; LOS, LI; VANDERVEEN, G; WORST, JGF

    1991-01-01

    Lens capsules of patients of advanced age, obtained after extracapsular cataract surgery, were carefully prepared for a combined LM, TEM and SEM investigation, after preliminary washing and mounting onto a holder in a buffer solution. After pre-fixation with GA, samples were postfixed for LM/TEM and

  13. Development and testing of an X-ray fluorescence source holder

    International Nuclear Information System (INIS)

    Csikai, J.

    1983-02-01

    For elemental analysis of low Z materials, the techniques of radioisotope excited X-ray emission was improved by the application of a vacuum chamber permitting the analysis of several samples without destroying the vacuum. The optimal geometry was determined, and the chamber designed and constructed to allow improved quantitative analysis of elements with Z<25. The contents of Ar in air permits the easy monitoring of the vacuum in the chamber, as this gas is also excited and emits characteristic X-rays. To maintain a low vacuum on the top of a solid-state detector, is important in laboratories with a high relative humidity, which can be detrimental to the thin Be window of the detector

  14. Electron microscopic observation at low temperature on superconductors

    International Nuclear Information System (INIS)

    Yokota, Yasuhiro; Hashimoto, Hatsujiro; Yoshida, Hiroyuki.

    1991-01-01

    The authors have observed superconducting materials with a high resolution electron microscope at liquid helium temperature. First, observation was carried out on Nb system intermetallic compounds such as Nb 3 Al and Nb 3 Sn of Al 5 type and Nb 3 Ge of 11 type at extremely low temperature. Next, the observation of high temperature superconductive ceramics in the state of superconductivity was attempted. In this paper, first the development of the liquid helium sample holder for a 400 kV electron microscope to realize the observation is reported. Besides, the sample holder of Gatan Co. and an extremely low temperature, high resolution electron microscope with a superconducting lens are described. The purpose of carrying out the electron microscope observation of superconductors at low temperature is the direct observation of the crystalline lattice image in the state of superconductivity. Also the structural transformation from tetragonal crystals to rhombic crystals in Al 5 type superconductors can be observed. The results of observation are reported. (K.I.)

  15. Design and construction of prompt-gamma spectroscopy facility applied to the boron determination

    International Nuclear Information System (INIS)

    Poblete, Victor; Henriquez, Carlos; Klein, Juan; Navarro, Gustavo

    1996-01-01

    A prompt-gamma spectroscopy facility was developed using the south tangential neutron beam of the RECH-1 research reactor for boron determination. The implementation of a thermal neutron beam was performed considering different aspects such as biological protection of working area and the beam collimation for a Ge detector, design and sample holder selection, standards and sample preparation. One ppm of Boron in different samples with counting-rate of 20 minutes and a good accuracy were determined. (author)

  16. Low conductive support for thermal insulation of a sample holder of a variable temperature scanning tunneling microscope

    Czech Academy of Sciences Publication Activity Database

    Hanzelka, Pavel; Vonka, J.; Musilová, Věra

    2013-01-01

    Roč. 84, č. 8 (2013), 085103:1-6 ISSN 0034-6748 R&D Projects: GA MŠk ED0017/01/01; GA TA ČR TE01020233 Institutional support: RVO:68081731 Keywords : Thermal conductiviy * Scanning tunneling microscope Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.584, year: 2013

  17. 77 FR 34445 - Self-Regulatory Organizations; NYSE Arca, Inc.; Notice of Filing and Immediate Effectiveness of...

    Science.gov (United States)

    2012-06-11

    ... Outsourcing Solutions, Inc. as an NYSE Arca ETP Holder and OTP Holder, Subject to Apex Clearing Complying With... Corporation, f/k/a Ridge Clearing and Outsourcing Solutions, Inc. (``Apex Clearing'') as an NYSE Arca ETP... could have a significant collateral impact to a number of other ETP Holders and OTP Holders. The...

  18. Exploring the Relationship between State Financial Aid Policy and Postsecondary Enrollment Choices: A Focus on Income and Race Differences

    Science.gov (United States)

    Kim, Jiyun

    2012-01-01

    This study explores the relationship between state financial aid policies and postsecondary enrollment for high school graduates (or equivalent diploma holders). Utilizing an event history modeling for a nationally representative sample from the National Education Longitudinal Study (NELS:88/2000) in addition to state-level policy variables, this…

  19. Attracting Women to Psychology: Effects of University Behavior and the Labor Market.

    Science.gov (United States)

    Solmon, Lewis C.

    1978-01-01

    This article reviews certain behaviors of graduate departments in regard to possible sex discrimination. It also evaluates job market conditions for men and women with data from a national sample of doctorate holders and from a recent survey of mobile or nontraditionally employed PhD's in psychology. (Author)

  20. Energy-dispersive X-ray microanalysis of elements' content and ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-05-18

    May 18, 2009 ... umbrosus, were collected from the Biodiversity Unit, Institute of. Bioscience (IBS), Universiti Putra Malaysia (UPM). Samples were cut into 1 X 1 mm, and mounted on Aluminium stub specimen holders and viewed under a variable pressure scanning electron microscope (VPSEM, EDX) model LEO1455 with ...

  1. Computer numerical control (CNC) lithography: light-motion synchronized UV-LED lithography for 3D microfabrication

    International Nuclear Information System (INIS)

    Kim, Jungkwun; Allen, Mark G; Yoon, Yong-Kyu

    2016-01-01

    This paper presents a computer-numerical-controlled ultraviolet light-emitting diode (CNC UV-LED) lithography scheme for three-dimensional (3D) microfabrication. The CNC lithography scheme utilizes sequential multi-angled UV light exposures along with a synchronized switchable UV light source to create arbitrary 3D light traces, which are transferred into the photosensitive resist. The system comprises a switchable, movable UV-LED array as a light source, a motorized tilt-rotational sample holder, and a computer-control unit. System operation is such that the tilt-rotational sample holder moves in a pre-programmed routine, and the UV-LED is illuminated only at desired positions of the sample holder during the desired time period, enabling the formation of complex 3D microstructures. This facilitates easy fabrication of complex 3D structures, which otherwise would have required multiple manual exposure steps as in the previous multidirectional 3D UV lithography approach. Since it is batch processed, processing time is far less than that of the 3D printing approach at the expense of some reduction in the degree of achievable 3D structure complexity. In order to produce uniform light intensity from the arrayed LED light source, the UV-LED array stage has been kept rotating during exposure. UV-LED 3D fabrication capability was demonstrated through a plurality of complex structures such as V-shaped micropillars, micropanels, a micro-‘hi’ structure, a micro-‘cat’s claw,’ a micro-‘horn,’ a micro-‘calla lily,’ a micro-‘cowboy’s hat,’ and a micro-‘table napkin’ array. (paper)

  2. MANIA (276-3/4/5). Nuclear analysis

    International Nuclear Information System (INIS)

    Sciolla, C.M.

    1993-11-01

    This report contains the results of the nuclear calculations performed for the MANIA-276 experiment, sample holders 3, 4 and 5. The codes MICROFLUX-2, GAM, HFR-TEDDI and ORIGEN-S have been used for this analysis. Nuclear constants, dpa, reactivity effect and activity of the samples and of the structural materials have been calculated. The results are given in the tables and appendices of the present report. (orig.)

  3. Prévalence de Acidovorax avenae subsp. avenae, agent des rayures bactériennes du riz dans les semences de base produites au Burkina Faso

    OpenAIRE

    Dakouo, D.; Ouedraogo, SL.; Somda, I.; Mortensen, CN.

    2005-01-01

    Prevalence of Bacterial Stripe Organism, Acidovorax avenae subsp. avenae, in Breeder Rice Seed Samples from Burkina Faso. Nine rice seed samples of improved and local varieties were tested at DGISP (Denmark) for the incidence of seed-borne bacterial stripe organism, Acidovorax avenae subsp. avenae, using the cassette holder method. Twenty-six suspected bacterial colonies were identified by different methods including colony morphology, pigmentation, biochemical and pathogenicity tests. Using ...

  4. 50 CFR 680.2 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... firm, accounting firm, etc.; (D) If a PQS or IPQ holder and QS or IFQ holder share the same office..., accounting firm, or broker of any PQS or IPQ holder with whom the QS or IFQ holder has entered into a... means the person identified on an IFQ permit. Crab LLP license history means, for any particular crab...

  5. 27 CFR 70.147 - Priority of interest and expenses.

    Science.gov (United States)

    2010-04-01

    ... interest is not subrogated to the rights of the holder of the State sales tax lien. However, if the holder... the rights of the holder of the sales tax lien, the holder of the lien or security interest will also... Collection of Excise and Special (Occupational) Tax Lien for Taxes § 70.147 Priority of interest and expenses...

  6. Design and construction of prompt-gamma spectroscopy facility applied to the boron determination; Diseno y construccion de una facilidad de espectrometria prompt-gamma aplicada a la determinacion de boro

    Energy Technology Data Exchange (ETDEWEB)

    Poblete, Victor; Henriquez, Carlos; Klein, Juan; Navarro, Gustavo [Comision Chilena de Energia Nuclear, Santiago (Chile). Centro de Estudios Nucleares La Reina, Comision Chis Nucleares La Reina, Comision Chi Reina

    1997-12-31

    A prompt-gamma spectroscopy facility was developed using the south tangential neutron beam of the RECH-1 research reactor for boron determination. The implementation of a thermal neutron beam was performed considering different aspects such as biological protection of working area and the beam collimation for a Ge detector, design and sample holder selection, standards and sample preparation. One ppm of Boron in different samples with counting-rate of 20 minutes and a good accuracy were determined. (author). 5 refs.

  7. Fine Needle Aspiration Cytology In Tumour Diagnosis | Obaseki ...

    African Journals Online (AJOL)

    Fine needle aspiration cytology (FNAC), a technique for obtaining cellular material for cytological examination and diagnosis using a 21- gauge or smaller needle, is performed using a 5, 10, or 20ml syringe either freehand or using special syringe holders. It allows a minimally invasive, rapid diagnosis of tissue samples but

  8. Pyrolysis kinetics and combustion of thin wood using advanced cone calorimetry test method

    Science.gov (United States)

    Mark A. Dietenberger

    2011-01-01

    Mechanistic pyrolysis kinetics analysis of extractives, holocellulose, and lignin in solid wood over entire heating regime was possible using specialized cone calorimeter test and new mathematical analysis tools. Added hardware components include: modified sample holder for thin specimen with tiny thermocouples, methane ring burner with stainless steel mesh above cone...

  9. Loss of collected particles from the filter of the stack monitor, the Ringhals-1 power reactor

    International Nuclear Information System (INIS)

    Stroem, L.

    1993-01-01

    The function of the filter holder was examined in the laboratory and in the Ringhals measurement installation. It was concluded that a loss of sample could occur, if the filter has a heavy particle deposit. An approximate relation between deposits thickness and loss of sample could be determined. Particle concentration in the stack air is sometimes so high, that loss of sample can occur. The test have also revealed that the sample air stream can by-pass the filter, without proper indication of the defect. Control instrumentation is proposed

  10. Sustaining Biodiversity and Income against Climate Change through Food Value Chain System by the Small-Holder Farmers in Southern Nigeria

    Directory of Open Access Journals (Sweden)

    Asadu Charles Livinus Anija

    2016-11-01

    Full Text Available Biodiversity and sustainable income are very necessary in ecosystem stability. The food value chain (FVC introduced in Nigeria to transform agriculture is commendable because through the system farmers receive various incentives as highly subsidized inputs from government and loans of low interest rates from designated Agricultural Banks and Central Bank. However, the system encourages specialization in the production of the reference crops but intercropping and mixed cropping systems practiced by most small-holder farmers because of its inherent advantages is de-emphasized or completely abandoned. This paper presents the results of two surveys of sole pepper and maize growers in 2015 and 2016 respectively as affected by sudden stoppage of rainfall in Nsukka area. The analyses showed that on the average > 70 % of the pepper farmers lost ≈ 65 % of their pepper fields while ≈ 57 % of the maize fields were lost. For a substitute intercropping system, plantain yield data from plantain plus moringa intercrop trials carried out in 2014 and 2015 were analyzed and projected to incorporate a food crop within inter-alleys. The mean plantain yields from the trials were 20 kg plant-1 for fresh bunch and 7 suckers stand-1. Based on a 6 m x 5 m (≈330 plants ha-1 spacing and the 2016 prices of bunches and suckers, these yields translated to a minimum net income per annum of N 1 320 000.00 (N 330 000.00 from bunches and N 990 000.00 from 6 suckers (net stand-1. Proceeds from the food crop, moringa seed and leaf extracts used as liquid fertilizer took care of the cost of other inputs and cultural practices. The inter-row spacing of 6 m allows mechanical cultivation of any food crop by the farmer. This system was considered a reliable insurance against climate change and pest insurgence and can be adopted by farmers in the entire southern Nigeria because both plantain and moringa can do very well in the subregion.

  11. Positioning X-Ray Film Inside A Flow Splitter

    Science.gov (United States)

    Darter, Charles; Pierce, Darryl

    1990-01-01

    Simple and inexpensive tool ensures secure placement for radiographic inspection. Holder places film positively and securely for x-ray inspection inside sections of tube with splitter welds. V-shaped piece of film fits on arms of holder. With arms squeezed together, holder inserted in opening of neck. Arms of holder cut from 0.020-in. (0.51-mm) thick stock of unspecified material.

  12. 14 CFR 43.3 - Persons authorized to perform maintenance, preventive maintenance, rebuilding, and alterations.

    Science.gov (United States)

    2010-01-01

    ... 125 of this chapter or any inspection performed after a major repair or alteration. (e) The holder of... alterations as provided in part 121 or 135. (g) Except for holders of a sport pilot certificate, the holder of... operated by that pilot which is not used under part 121, 129, or 135 of this chapter. The holder of a sport...

  13. Time-resolved magnetic imaging in an aberration-corrected, energy-filtered photoemission electron microscope

    International Nuclear Information System (INIS)

    Nickel, F.; Gottlob, D.M.; Krug, I.P.; Doganay, H.; Cramm, S.; Kaiser, A.M.; Lin, G.; Makarov, D.; Schmidt, O.G.

    2013-01-01

    We report on the implementation and usage of a synchrotron-based time-resolving operation mode in an aberration-corrected, energy-filtered photoemission electron microscope. The setup consists of a new type of sample holder, which enables fast magnetization reversal of the sample by sub-ns pulses of up to 10 mT. Within the sample holder current pulses are generated by a fast avalanche photo diode and transformed into magnetic fields by means of a microstrip line. For more efficient use of the synchrotron time structure, we developed an electrostatic deflection gating mechanism capable of beam blanking within a few nanoseconds. This allows us to operate the setup in the hybrid bunch mode of the storage ring facility, selecting one or several bright singular light pulses which are temporally well-separated from the normal high-intensity multibunch pulse pattern. - Highlights: • A new time-resolving operation mode in photoemission electron microscopy is shown. • Our setup works within an energy-filtered, aberration-corrected PEEM. • A new gating system for bunch selection using synchrotron radiation is developed. • An alternative magnetic excitation system is developed. • First tr-imaging using an energy-filtered, aberration-corrected PEEM is shown

  14. Modeling of temperature profiles in an environmental transmission electron microscope using computational fluid dynamics

    International Nuclear Information System (INIS)

    Mølgaard Mortensen, Peter; Willum Hansen, Thomas; Birkedal Wagner, Jakob; Degn Jensen, Anker

    2015-01-01

    The temperature and velocity field, pressure distribution, and the temperature variation across the sample region inside an environmental transmission electron microscope (ETEM) have been modeled by means of computational fluid dynamics (CFD). Heating the sample area by a furnace type TEM holder gives rise to temperature gradients over the sample area. Three major mechanisms have been identified with respect to heat transfer in the sample area: radiation from the grid, conduction in the grid, and conduction in the gas. A parameter sensitivity analysis showed that the sample temperature was affected by the conductivity of the gas, the emissivity of the sample grid, and the conductivity of the grid. Ideally the grid should be polished and made from a material with good conductivity, e.g. copper. With hydrogen gas, which has the highest conductivity of the gases studied, the temperature difference over the TEM grid is less than 5 °C, at what must be considered typical conditions, and it is concluded that the conditions on the sample grid in the ETEM can be considered as isothermal during general use. - Highlights: • Computational fluid dynamics used for mapping flow and temperature in ETEM setup. • Temperature gradient across TEM grid in furnace based heating holder very small in ETEM. • Conduction from TEM grid and gas in addition to radiation from TEM grid most important. • Pressure drop in ETEM limited to the pressure limiting apertures

  15. Approach to Multifunctional Device Platform with Epitaxial Graphene on Transition Metal Oxide (Postprint)

    Science.gov (United States)

    2015-09-23

    layers, respectively. 15. SUBJECT TERMS Heterostructures, two-dimensional materials, van der Waals interaction , 2D graphene, metal oxide (TiO2...sample holder with a 10.6 μ m CO2 IR laser . The laser output power was adjusted until the target temperature was reached. The temperature of the sample... Laser Deposited Transition- Metal Carbides for Field-Emission Cathode Coatings. ACS Appl. Mater. Interfaces 5, 9241–9246 (2013). 13. Swift, G. A

  16. Pyrolysis kinetics and combustion of thin wood by an advanced cone caorimetry test method

    Science.gov (United States)

    Mark Dietenberger

    2012-01-01

    Pyrolysis kinetics analysis of extractives, holocellulose, and lignin in the solid redwood over the entire heating regime was possible by specialized cone calorimeter test and new mathematical analysis tools. Added hardware components include: modified sample holder for the thin specimen with tiny thermocouples, the methane ring burner with stainless-steel mesh above...

  17. Derfor holder stamceller sammen

    DEFF Research Database (Denmark)

    Keiding, Johanne

    2013-01-01

    Professor Joshua Brickman fra DanStem har i samarbejde med forskere fra The MRC Centre for Regenerative Medicine (CRM) ved University of Edinburgh identificeret en række faktorer, som regulerer embryonale stamcellers evne til at forny sig selv. Et af de centrale elementer er proteinet Oct4, og...

  18. Patients as Rights Holders.

    Science.gov (United States)

    Brännmark, Johan

    2017-07-01

    Autonomy and consent have been central values in Western moral and political thought for centuries. One way of understanding the bioethical models that started to develop, especially in the 1970s, is that they were about the fusion of a long-standing professional ethics with the core values underpinning modern political institutions. That there was a need for this kind of fusion is difficult to dispute, especially since the provision of health care has in most developed countries become an ever more important concern of our political institutions, with governments playing a significant role in regulating and facilitating the provision of health care and in many countries even largely organizing it. There is, nevertheless, still room for dispute about how best to achieve this fusion and how to best think about autonomy and consent in a biomedical context. The simplest model we can have is probably about how being a person is largely about having the capacity of autonomous choice and that the main mode through which we exercise autonomy is by providing informed consent. Yet, liberal democracy's core idea that human beings have a high and equal value is also found in other accounts of the person. The human-rights framework provides an alternative model for thinking about personhood and about patient care. The human-rights approach is grounded, not in an account of autonomy (although it has something to say about autonomy), but in an account of the moral and political personhood that people possess merely by being human beings. In this approach, values like dignity and integrity, both highly relevant in a bioethical context, are identified as distinct values rather than being derived from and therefore reduced to respect for autonomous choice. The human-rights approach can supplement the problematic notion of autonomy that has been central to bioethics by placing this notion in a broader, strongly pluralistic framework. © 2017 The Hastings Center.

  19. Dosimeter design specifications

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The combination dosimeter and security credential holder was developed as part of the effort involved to provide an automated readout and thermoluminescent dosimetry capability at Hanford. The holder is designed to accomodate the thermoluminescent dosimeter card, appropriate filters, the security credential and a snap type clip. The body of the holder is ABS plastic (acrylontrile-butadiene-styrene). The dosimeter holder and card is mold casted providing uniformity of construction

  20. Systematic sampling with errors in sample locations

    DEFF Research Database (Denmark)

    Ziegel, Johanna; Baddeley, Adrian; Dorph-Petersen, Karl-Anton

    2010-01-01

    analysis using point process methods. We then analyze three different models for the error process, calculate exact expressions for the variances, and derive asymptotic variances. Errors in the placement of sample points can lead to substantial inflation of the variance, dampening of zitterbewegung......Systematic sampling of points in continuous space is widely used in microscopy and spatial surveys. Classical theory provides asymptotic expressions for the variance of estimators based on systematic sampling as the grid spacing decreases. However, the classical theory assumes that the sample grid...... is exactly periodic; real physical sampling procedures may introduce errors in the placement of the sample points. This paper studies the effect of errors in sample positioning on the variance of estimators in the case of one-dimensional systematic sampling. First we sketch a general approach to variance...

  1. [A comparison of convenience sampling and purposive sampling].

    Science.gov (United States)

    Suen, Lee-Jen Wu; Huang, Hui-Man; Lee, Hao-Hsien

    2014-06-01

    Convenience sampling and purposive sampling are two different sampling methods. This article first explains sampling terms such as target population, accessible population, simple random sampling, intended sample, actual sample, and statistical power analysis. These terms are then used to explain the difference between "convenience sampling" and purposive sampling." Convenience sampling is a non-probabilistic sampling technique applicable to qualitative or quantitative studies, although it is most frequently used in quantitative studies. In convenience samples, subjects more readily accessible to the researcher are more likely to be included. Thus, in quantitative studies, opportunity to participate is not equal for all qualified individuals in the target population and study results are not necessarily generalizable to this population. As in all quantitative studies, increasing the sample size increases the statistical power of the convenience sample. In contrast, purposive sampling is typically used in qualitative studies. Researchers who use this technique carefully select subjects based on study purpose with the expectation that each participant will provide unique and rich information of value to the study. As a result, members of the accessible population are not interchangeable and sample size is determined by data saturation not by statistical power analysis.

  2. Patterns of Wildlife Value Orientations

    Science.gov (United States)

    Harry C. Zinn; Michael J. Manfredo; Susan C. Barro

    2002-01-01

    Public value orientations toward wildlife may be growing less utilitarian and more protectionist. To better understand one aspect of this trend, we investigated patterns of wildlife value orientations within families. Using a mail survey, we sampled Pennsylvania and Colorado hunting license holders 50 or older; obtaining a 54% response rate (n = 599). Males (94% of...

  3. A simple, ultrahigh vacuum compatible scanning tunneling microscope for use at variable temperatures

    NARCIS (Netherlands)

    Mugele, Friedrich Gunther; Kloos, Ch.; Leiderer, P.; Moller, R.

    1996-01-01

    We present the construction of a very compact scanning tunneling microscope (STM) which can be operated at temperatures between 4 and 350 K. The tip and a tiny tip holder are the only movable parts, whereas the sample and the piezoscanner are rigidly attached to the body of the STM. This leads to an

  4. In situ mechanical TEM: seeing and measuring under stress with electrons

    International Nuclear Information System (INIS)

    Legros, M.

    2014-01-01

    From the first observation of moving dislocations in 1956 to the latest developments of piezo-actuated sample holders and direct electron sensing cameras in modern transmission electron microscopes (TEM), in situ mechanical testing has brought an unequaled view of the involved mechanisms during the plastic deformation of materials. Although MEMS-based or load-cell equipped holders provide an almost direct measure of these quantities, deriving stress and strain from in situ TEM experiments has an extensive history. Nowadays, the realization of a complete mechanical test while observing the evolution of a dislocation structure is possible, and it constitutes the perfect combination to explore size effects in plasticity. New cameras, data acquisition rates and intrinsic image-related techniques, such as holography, should extend the efficiency and capabilities of in situ deformation inside a TEM. (author)

  5. 77 FR 23490 - Agency Information Collection Activities: Country of Origin Marking Requirements for Containers...

    Science.gov (United States)

    2012-04-19

    ... Activities: Country of Origin Marking Requirements for Containers or Holders AGENCY: U.S. Customs and Border... of Origin Marking Requirements for Containers or Holders. This is a proposed extension of an... Requirements for Containers or Holders. [[Page 23491

  6. Heteronuclear Micro-Helmholtz Coil Facilitates µm-Range Spatial and Sub-Hz Spectral Resolution NMR of nL-Volume Samples on Customisable Microfluidic Chips.

    Directory of Open Access Journals (Sweden)

    Nils Spengler

    Full Text Available We present a completely revised generation of a modular micro-NMR detector, featuring an active sample volume of ∼ 100 nL, and an improvement of 87% in probe efficiency. The detector is capable of rapidly screening different samples using exchangeable, application-specific, MEMS-fabricated, microfluidic sample containers. In contrast to our previous design, the sample holder chips can be simply sealed with adhesive tape, with excellent adhesion due to the smooth surfaces surrounding the fluidic ports, and so withstand pressures of ∼2.5 bar, while simultaneously enabling high spectral resolution up to 0.62 Hz for H2O, due to its optimised geometry. We have additionally reworked the coil design and fabrication processes, replacing liquid photoresists by dry film stock, whose final thickness does not depend on accurate volume dispensing or precise levelling during curing. We further introduced mechanical alignment structures to avoid time-intensive optical alignment of the chip stacks during assembly, while we exchanged the laser-cut, PMMA spacers by diced glass spacers, which are not susceptible to melting during cutting. Doing so led to an overall simplification of the entire fabrication chain, while simultaneously increasing the yield, due to an improved uniformity of thickness of the individual layers, and in addition, due to more accurate vertical positioning of the wirebonded coils, now delimited by a post base plateau. We demonstrate the capability of the design by acquiring a 1H spectrum of ∼ 11 nmol sucrose dissolved in D2O, where we achieved a linewidth of 1.25 Hz for the TSP reference peak. Chemical shift imaging experiments were further recorded from voxel volumes of only ∼ 1.5 nL, which corresponded to amounts of just 1.5 nmol per voxel for a 1 M concentration. To extend the micro-detector to other nuclei of interest, we have implemented a trap circuit, enabling heteronuclear spectroscopy, demonstrated by two 1H/13C 2D HSQC

  7. Simple and versatile turbidimetric monitoring of bacterial growth in liquid cultures using a customized 3D printed culture tube holder and a miniaturized spectrophotometer: application to facultative and strictly anaerobic bacteria

    Directory of Open Access Journals (Sweden)

    Margarida R. G. Maia

    2016-08-01

    Full Text Available Here we introduce a novel strategy for turbidimetric monitoring of bacterial growth in liquid culture. The instrumentation comprises a light source, a customized 3D printed culture tube holder and a miniaturized spectrophotometer, connected through optical cables. Due to its small footprint and the possibility to operate with external light, bacterial growth was directly monitored from culture tubes in a simple and versatile fashion. This new portable measurement technique was used to monitor the growth of facultative (Escherichia coli ATCC/25922, and Staphylococcus aureus ATCC/29213 and strictly (Butyrivibrio fibrisolvens JW11, Butyrivibrio proteoclasticus P18, and Propionibacterium acnes DSMZ 1897 anaerobic bacteria. For E. coli and S. aureus, the growth rates calculated from normalized optical density values were compared with those ones obtained using a benchtop spectrophotometer without significant differences (P = 0.256. For the strictly anaerobic species, a high precision (RSD < 3.5% was observed between replicates up to 48 h. Regarding its potential for customization, this manifold could accommodate further developments for customized turbidimetric monitoring, such as the use of light-emitting diodes as a light source or flow cells.

  8. Simple and Versatile Turbidimetric Monitoring of Bacterial Growth in Liquid Cultures Using a Customized 3D Printed Culture Tube Holder and a Miniaturized Spectrophotometer: Application to Facultative and Strictly Anaerobic Bacteria.

    Science.gov (United States)

    Maia, Margarida R G; Marques, Sara; Cabrita, Ana R J; Wallace, R John; Thompson, Gertrude; Fonseca, António J M; Oliveira, Hugo M

    2016-01-01

    Here we introduce a novel strategy for turbidimetric monitoring of bacterial growth in liquid culture. The instrumentation comprises a light source, a customized 3D printed culture tube holder and a miniaturized spectrophotometer, connected through optical cables. Due to its small footprint and the possibility to operate with external light, bacterial growth was directly monitored from culture tubes in a simple and versatile fashion. This new portable measurement technique was used to monitor the growth of facultative (Escherichia coli ATCC/25922, and Staphylococcus aureus ATCC/29213) and strictly (Butyrivibrio fibrisolvens JW11, Butyrivibrio proteoclasticus P18, and Propionibacterium acnes DSMZ 1897) anaerobic bacteria. For E. coli and S. aureus, the growth rates calculated from normalized optical density values were compared with those ones obtained using a benchtop spectrophotometer without significant differences (P = 0.256). For the strictly anaerobic species, a high precision (relative standard deviation < 3.5%) was observed between replicates up to 48 h. Regarding its potential for customization, this manifold could accommodate further developments for customized turbidimetric monitoring, such as the use of light-emitting diodes as a light source or flow cells.

  9. Optomechanical Design of a Hard X-ray Nanoprobe Instrument with Nanometer-Scale Active Vibration Control

    International Nuclear Information System (INIS)

    Shu, D.; Preissner, C.; Smolyanitskiy, A.; Maser, J.; Winarski, R.; Holt, M.; Lai, B.; Vogt, S.; Stephenson, G. B.

    2007-01-01

    We are developing a new hard x-ray nanoprobe instrument that is one of the centerpieces of the characterization facilities of the Center for Nanoscale Materials being constructed at Argonne National Laboratory. This new probe will cover an energy range of 3-30 keV with 30-nm spacial resolution. The system is designed to accommodate x-ray optics with a resolution limit of 10 nm, therefore, it requires staging of x-ray optics and specimens with a mechanical repeatability of better than 5 nm. Fast feedback for differential vibration control between the zone-plate x-ray optics and the sample holder has been implemented in the design using a digital-signal-processor-based real-time closed-loop feedback technique. A specially designed, custom-built laser Doppler displacement meter system provides two-dimensional differential displacement measurements with subnanometer resolution between the zone-plate x-ray optics and the sample holder. The optomechanical design of the instrument positioning stage system with nanometer-scale active vibration control is presented in this paper

  10. Optomechanical design of a hard x-ray nanoprobe instrument with active vibration control in nanometer scale

    International Nuclear Information System (INIS)

    Shu, D.; Maser, J.; Holt, M.; Winarski, R.; Preissner, C.; Smolyanitskiy, A.; Lai, B.; Vogt, S.; Stephenson, G.

    2007-01-01

    We are developing a new hard x-ray nanoprobe instrument that is one of the centerpieces of the characterization facilities of the Center for Nanoscale Materials being constructed at Argonne National Laboratory. This new probe will cover an energy range of 3-30 keV with 30-nm spatial resolution. The system is designed to accommodate x-ray optics with a resolution limit of 10 nm, therefore, it requires staging of x-ray optics and specimens with a mechanical repeatability of better than 5 nm. Fast feedback for differential vibration control between the zone-plate x-ray optics and the sample holder has been implemented in the design using a digital-signal-processor-based real-time closed-loop feedback technique. A specially designed, custom-built laser Doppler displacement meter system provides two-dimensional differential displacement measurements with subnanometer resolution between the zone-plate x-ray optics and the sample holder. The optomechanical design of the instrument positioning stage system with nanometer-scale active vibration control is presented in this paper.

  11. Asset Structure Impact on Capital Structure of Capital Market-Listed Firms in Indonesia and Malaysia

    Directory of Open Access Journals (Sweden)

    Zainal Abidin Sahabuddin

    2017-07-01

    Full Text Available Debt was able to be used by firm as source of funds for investment-related activities,especially when the amount of retained earnings was not sufficient to cover the amount of investment needed. Naturally, the use of debt definitely caused the agency conflict between firm shareholders and debt holders. To reduce this conflict, the existence of fixed assets as collateral was needed when firm decided to borrow money from debt holders.The purpose of this study was to prove the agency theory perspective by testing an impact of asset structure on capital structure of firms. The population of this study was the firms listed on Indonesia Stock Exchange and Malaysian Stock Exchange. The firms as sample were taken from the population by conducting stratified random sampling method. The pooled data regression model was used as the data analysis method. This result of this study showed that asset structure had the positive impact on capital structure. It meant the causal relationship between asset structure and capital structure happened and was supported by the agency theory perspective.

  12. The contribution of demographic and morbidity factors to self-reported visit frequency of patients: a cross-sectional study of general practice patients in Australia

    Directory of Open Access Journals (Sweden)

    Britt Helena

    2004-08-01

    Full Text Available Abstract Background Understanding the factors that affect patients' utilisation of health services is important for health service provision and effective patient management. This study aimed to investigate the specific morbidity and demographic factors related to the frequency with which general practice patients visit a general practitioner/family physician (GP in Australia. Methods A sub-study was undertaken as part of an ongoing national study of general practice activity in Australia. A cluster sample of 10,755 general practice patients were surveyed through a random sample of 379 general practitioners. The patient reported the number of times he/she had visited a general practitioner in the previous twelve months. The GP recorded all the patient's major health problems, including those managed at the current consultation. Results Patients reported an average of 8.8 visits to a general practitioner per year. After adjusting for other patient demographics and number of health problems, concession health care card holders made on average 2.6 more visits per year to a general practitioner than did non-card holders (p Conclusions Anxiety, back pain and depression are associated with greater patient demand for general practice services than other health problems. The effect of sociodemographic factors on patient utilisation of general practice services is complex. Equity of access to general practice services remains an issue for patients from remote areas, while concession health care card holders are attending general practice more frequently than other patients relative to their number of health problems.

  13. Application of a Betatron in Photonuclear Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Brune, D [AB Atomenergi, Nykoeping (Sweden); Mattsson, K; Liden, K [Dept . of Radiation Physics, Univ. of Lund (Sweden)

    1968-08-15

    The present study concerns the determination of fluorine, iodine, lead and mercury by means of photonuclear activation technique using a betatron. The detection limit obtained for the elements in the above given sequence amounted to 3, 50, 400 and 15 {mu}g respectively. The technique has been applied in the determination of iodine in pharmaceuticals. A rotating sample holder device was inserted in the Bremsstrahlung beam of the betatron in order to ensure uniform irradiation of the samples.

  14. Male sex, height, weight, and body mass index can increase external pressure to calf region using knee-crutch-type leg holder system in lithotomy position.

    Science.gov (United States)

    Mizuno, Ju; Takahashi, Toru

    2016-01-01

    Well-leg compartment syndrome (WLCS) is one of the catastrophic complications related to prolonged surgical procedures performed in the lithotomy position, using a knee-crutch-type leg holder (KCLH) system, to support the popliteal fossae and calf regions. Obesity has been implicated as a risk factor in the lithotomy position-related WLCS during surgery. In the present study, we investigated the relationship between the external pressure (EP) applied to the calf region using a KCLH system in the lithotomy position and selected physical characteristics. Twenty-one young, healthy volunteers (21.4±0.5 years of age, eleven males and ten females) participated in this study. The KCLH system used was Knee Crutch(®). We assessed four types of EPs applied to the calf region: box pressure, peak box pressure, contact pressure, and peak contact pressure, using pressure-distribution measurement system (BIG-MAT(®)). Relationships between these four EPs to the calf regions of both lower legs and a series of physical characteristics (sex, height, weight, and body mass index [BMI]) were analyzed. All four EPs applied to the bilateral calf regions were higher in males than in females. For all subjects, significant positive correlations were observed between all four EPs and height, weight, and BMI. EP applied to the calf region is higher in males than in females when the subject is supported by a KCLH system in the lithotomy position. In addition, EP increases with the increase in height, weight, and BMI. Therefore, male sex, height, weight, and BMI may contribute to the risk of inducing WLCS.

  15. 32P-postlabeling assay for carcinogen-DNA adducts: description of beta shielding apparatus and semi-automatic spotting and washing devices that facilitate the handling of multiple samples

    International Nuclear Information System (INIS)

    Reddy, M.V.; Blackburn, G.R.

    1990-01-01

    The utilization of the 32 P-postlabeling assay in combination with TLC for the sensitive detection and estimation of aromatic DNA adducts has been increasing. The procedure consists of 32 P-labeling of carcinogen-adducted 3'-nucleotides in the DNA digests using γ- 32 P ATP and polynucleotide kinase, separation of 32 P-labeled adducts by TLC, and their detection by autoradiography. During both 32 P-labeling and initial phases of TLC, a relatively high amount of γ- 32 P ATP is handled when 30 samples are processed simultaneously. We describe the design of acrylic shielding apparatus, semi-automatic TLC spotting devices, and devices for development and washing of multiple TLC plates, which not only provide substantial protection from exposure to 32 P beta radiation, but also allow quick and easy handling of a large number of samples. Specifically, the equipment includes: (i) a multi-tube carousel rack having 15 wells to hold capless Eppendorf tubes and a rotatable lid with an aperture to access individual tubes; (ii) a pipette shielder; (iii) two semi-automatic spotting devices to apply radioactive solutions to TLC plates; (iv) a multi-plate holder for TLC plates; and (v) a mechanical device for washing multiple TLC plates. Item (i) is small enough to be held in one-hand, vortexed, and centrifuged to mix the solutions in each tube while beta radiation is shielded. Items (iii) to (iv) aid in the automation of the assay. (author)

  16. Radiation damage studies of straw tube and scintillating fiber elements

    International Nuclear Information System (INIS)

    Dunn, W.L.; Elleman, T.S.; Goshaw, A.T.; Oh, S.H.; Robertson, W.J.; Grimes, A.; Leedom, I.; Reucroft, S.

    1990-01-01

    The authors report on the results of mixed-field irradiations of straw-tube, plastic scintillating fiber, and avalanche photodiode components. These irradiations are being carried out at the one-MW PULSTAR research reactor facility at North Carolina State University. A special sample holder was designed that allows relatively uniform irradiation of samples up to 5 ft long, without bending or coiling. A systematic irradiation program is underway that allows study of total fluence, fluence-rate, and neutron spectral effects. Samples have been exposed to neutron fluences as high as 2 x 10 16 cm -2

  17. Information sampling behavior with explicit sampling costs

    Science.gov (United States)

    Juni, Mordechai Z.; Gureckis, Todd M.; Maloney, Laurence T.

    2015-01-01

    The decision to gather information should take into account both the value of information and its accrual costs in time, energy and money. Here we explore how people balance the monetary costs and benefits of gathering additional information in a perceptual-motor estimation task. Participants were rewarded for touching a hidden circular target on a touch-screen display. The target’s center coincided with the mean of a circular Gaussian distribution from which participants could sample repeatedly. Each “cue” — sampled one at a time — was plotted as a dot on the display. Participants had to repeatedly decide, after sampling each cue, whether to stop sampling and attempt to touch the hidden target or continue sampling. Each additional cue increased the participants’ probability of successfully touching the hidden target but reduced their potential reward. Two experimental conditions differed in the initial reward associated with touching the hidden target and the fixed cost per cue. For each condition we computed the optimal number of cues that participants should sample, before taking action, to maximize expected gain. Contrary to recent claims that people gather less information than they objectively should before taking action, we found that participants over-sampled in one experimental condition, and did not significantly under- or over-sample in the other. Additionally, while the ideal observer model ignores the current sample dispersion, we found that participants used it to decide whether to stop sampling and take action or continue sampling, a possible consequence of imperfect learning of the underlying population dispersion across trials. PMID:27429991

  18. New type of thermal analyzer with a micro-air-bridge heater

    Science.gov (United States)

    Kimura, Mitsuteru; Hayasaka, Junichi

    1997-11-01

    Miniaturized sensor for thermal analysis is fabricated using micromachining technique and its fundament al characteristics are obtained. This device fabricated in a Si substrate consists of monolithically integrated components of an air-bridge type microheater, a thin film thermocouple and a sample-holder. Boiling points of liquid samples, water and methanol, are observed in the heating curve and the heating-rate curve, and sudden decrease of the temperature at the dropping time of the liquid samples at room temperature due to the effect of evaporation heat is also observed. Loss of the sample due to the evaporation during heating was theoretically discussed.

  19. 40 CFR Appendix A-3 to Part 60 - Test Methods 4 through 5I

    Science.gov (United States)

    2010-07-01

    ... (see Section 2.0). 8.2.1Place exactly 5 ml water in each impinger. Leak check the sampling train as... this will cause water to back up into the filter holder. If the desired vacuum is exceeded, either leak... Note: This method does not include all the specifications (e.g., equipment and supplies) and procedures...

  20. Preparation and crystal structure characterization of CuNiGaSe3 ...

    Indian Academy of Sciences (India)

    Administrator

    These values are in good agreement with the ideal composition 1 : 1: 1 : 3. The error in standardless analysis was around 5%. 2.3 X-ray powder diffraction. For the X-ray analysis, small quantities of the samples were ground mechanically in an agate mortar and pestle and mounted on a flat zero-background holder covered.

  1. Samples and Sampling Protocols for Scientific Investigations | Joel ...

    African Journals Online (AJOL)

    ... from sampling, through sample preparation, calibration to final measurement and reporting. This paper, therefore offers useful information on practical guidance on sampling protocols in line with best practice and international standards. Keywords: Sampling, sampling protocols, chain of custody, analysis, documentation ...

  2. Public Notice of Nuclear Regulatory Authority of the Slovak Republic No. 52/2006 Coll. on professional competence

    International Nuclear Information System (INIS)

    Szabo, V.

    2006-01-01

    The Public Notice has replaced the previous Public Notice of Nuclear Regulatory Authority of the Slovak Republic No. 187/1999 Coll. on Professional competence of employees of nuclear power facilities. The new experience acquired in area of Professional preparation of employees holders of permissions has been included into the Public Notice as well as acknowledged principles of verification of the Professional competence and specific Professional competence of employees holders of permissions. There are rights and duties of permission holders elaborated in the Public Notice where the employees have an influence to the nuclear safety (professionally competent employees of permission holders) or have the direct influence to the nuclear safety (selected employees of permission holders). The Public Notice has also modified the details about preparation of employees of the operator of specific facilities who carry out the professional preparation of the employees holders of permissions

  3. 77 FR 6815 - Agency Information Collection Activities: Country of Origin Marking Requirements for Containers...

    Science.gov (United States)

    2012-02-09

    ... Activities: Country of Origin Marking Requirements for Containers or Holders AGENCY: U.S. Customs and Border... information collection requirement concerning Country of Origin Marking Requirements for Containers or Holders...: Title: Country of Origin Marking Requirements for Containers or Holders. OMB Number: 1651-0057. Form...

  4. 17 CFR 240.14b-1 - Obligation of registered brokers and dealers in connection with the prompt forwarding of certain...

    Science.gov (United States)

    2010-04-01

    ... security holders, proxy statement, information statement, or Notice of Internet Availability of Proxy...(e)(1) (with respect to annual reports to security holders, proxy statements, and Notices of Internet... or Notice of Internet Availability of Proxy Materials to security holders. (2) Establish a Web site...

  5. Sampling and chemical analysis in environmental samples around Nuclear Power Plants and some environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2002-12-15

    Twelve kinds of environmental samples such as soil, seawater, underground water, etc. around Nuclear Power Plants(NPPs) were collected. Tritium chemical analysis was tried for the samples of rain water, pine-needle, air, seawater, underground water, chinese cabbage, a grain of rice and milk sampled around NPPs, and surface seawater and rain water sampled over the country. Strontium in the soil that sere sampled at 60 point of district in Korea were analyzed. Tritium were sampled at 60 point of district in Korea were analyzed. Tritium were analyzed in 21 samples of surface seawater around the Korea peninsular that were supplied from KFRDI(National Fisheries Research and Development Institute). Sampling and chemical analysis environmental samples around Kori, Woolsung, Youngkwang, Wooljin Npps and Taeduk science town for tritium and strontium analysis was managed according to plans. Succeed to KINS after all samples were tried.

  6. 14 CFR 135.129 - Exit seating.

    Science.gov (United States)

    2010-01-01

    ... emergency evacuation provided by the certificate holder in printed or graphic form or the ability to... accordance with this section. (d) Each certificate holder shall include on passenger information cards.... (e) Each certificate holder shall include on passenger information cards, at each exit seat— (1) In...

  7. 76 FR 65180 - Proposed Information Collection; Comment Request; Application to Shuck Surf Clams/Ocean Quahogs...

    Science.gov (United States)

    2011-10-20

    .... Method of Collection Requests from allocation holders to transfer quota use paper applications or an... submitted on or before December 19, 2011. ADDRESSES: Direct all written comments to Diana Hynek... transferable quota (ITQ) allocation holders in order to process and track requests from the allocation holders...

  8. Pierre Gy's sampling theory and sampling practice heterogeneity, sampling correctness, and statistical process control

    CERN Document Server

    Pitard, Francis F

    1993-01-01

    Pierre Gy's Sampling Theory and Sampling Practice, Second Edition is a concise, step-by-step guide for process variability management and methods. Updated and expanded, this new edition provides a comprehensive study of heterogeneity, covering the basic principles of sampling theory and its various applications. It presents many practical examples to allow readers to select appropriate sampling protocols and assess the validity of sampling protocols from others. The variability of dynamic process streams using variography is discussed to help bridge sampling theory with statistical process control. Many descriptions of good sampling devices, as well as descriptions of poor ones, are featured to educate readers on what to look for when purchasing sampling systems. The book uses its accessible, tutorial style to focus on professional selection and use of methods. The book will be a valuable guide for mineral processing engineers; metallurgists; geologists; miners; chemists; environmental scientists; and practit...

  9. Systematic Sampling and Cluster Sampling of Packet Delays

    OpenAIRE

    Lindh, Thomas

    2006-01-01

    Based on experiences of a traffic flow performance meter this papersuggests and evaluates cluster sampling and systematic sampling as methods toestimate average packet delays. Systematic sampling facilitates for exampletime analysis, frequency analysis and jitter measurements. Cluster samplingwith repeated trains of periodically spaced sampling units separated by randomstarting periods, and systematic sampling are evaluated with respect to accuracyand precision. Packet delay traces have been ...

  10. Quantitative EDXS: Influence of geometry on a four detector system

    International Nuclear Information System (INIS)

    Kraxner, Johanna; Schäfer, Margit; Röschel, Otto; Kothleitner, Gerald; Haberfehlner, Georg; Paller, Manuel; Grogger, Werner

    2017-01-01

    The influence of the geometry on quantitative energy dispersive X-ray spectrometry (EDXS) analysis is determined for a ChemiSTEM system (Super-X) in combination with a low-background double-tilt specimen holder. For the first time a combination of experimental measurements with simulations is used to determine the positions of the individual detectors of a Super-X system. These positions allow us to calculate the detector's solid angles and estimate the amount of detector shadowing and its influence on quantitative EDXS analysis, including absorption correction using the ζ-factor method. Both shadowing by the brass portions and the beryllium specimen carrier of the holder severely affect the quantification of low to medium atomic number elements. A multi-detector system is discussed in terms of practical consequences of the described effects, and a quantitative evaluation of a Fayalit sample is demonstrated. Corrections and suggestions for minimizing systematic errors are discussed to improve quantitative methods for a multi-detector system. - Highlights: • Geometrical issues for EDXS quantification on a Super-X system. • Realistic model of a specimen holder using X-ray computed tomography. • Determination of the exact detector positions of a Super-X system. • Influence of detector shadowing and Be specimen carrier on quantitative EDXS.

  11. 26 CFR 1.58-6 - Regulated investment companies; real estate investment trusts.

    Science.gov (United States)

    2010-04-01

    ... shareholder, or holder of beneficial interest, bear to the taxable income of such company or such trust... the shareholders, or holders of beneficial interest, in the same taxable year in which the dividends... are allocated to the shareholders or holders of beneficial interests. (b) Capital gains. Section 58(g...

  12. 26 CFR 1.108-2 - Acquisition of indebtedness by a person related to the debtor.

    Science.gov (United States)

    2010-04-01

    ... its portfolio investment activities and the holder's acquisition of the indebtedness preceded any... debtor represents more than 25 percent of the fair market value of the total gross assets of the holder... in which the holder has substantially reduced its risk of loss. In addition, total gross assets do...

  13. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  14. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  15. Choosing a suitable sample size in descriptive sampling

    International Nuclear Information System (INIS)

    Lee, Yong Kyun; Choi, Dong Hoon; Cha, Kyung Joon

    2010-01-01

    Descriptive sampling (DS) is an alternative to crude Monte Carlo sampling (CMCS) in finding solutions to structural reliability problems. It is known to be an effective sampling method in approximating the distribution of a random variable because it uses the deterministic selection of sample values and their random permutation,. However, because this method is difficult to apply to complex simulations, the sample size is occasionally determined without thorough consideration. Input sample variability may cause the sample size to change between runs, leading to poor simulation results. This paper proposes a numerical method for choosing a suitable sample size for use in DS. Using this method, one can estimate a more accurate probability of failure in a reliability problem while running a minimal number of simulations. The method is then applied to several examples and compared with CMCS and conventional DS to validate its usefulness and efficiency

  16. Sampling and examination methods used for TMI-2 samples

    International Nuclear Information System (INIS)

    Marley, A.W.; Akers, D.W.; McIsaac, C.V.

    1988-01-01

    The purpose of this paper is to summarize the sampling and examination techniques that were used in the collection and analysis of TMI-2 samples. Samples ranging from auxiliary building air to core debris were collected and analyzed. Handling of the larger samples and many of the smaller samples had to be done remotely and many standard laboratory analytical techniques were modified to accommodate the extremely high radiation fields associated with these samples. The TMI-2 samples presented unique problems with sampling and the laboratory analysis of prior molten fuel debris. 14 refs., 8 figs

  17. A wall-free climate unit for acoustic levitators.

    Science.gov (United States)

    Schlegel, M C; Wenzel, K-J; Sarfraz, A; Panne, U; Emmerling, F

    2012-05-01

    Acoustic levitation represents the physical background of trapping a sample in a standing acoustic wave with no contact to the wave generating device. For the last three decades, sample holders based on this effect have been commonly used for contact free handling of samples coupled with a number of analytical techniques. In this study, a wall-free climate unit is presented, which allows the control of the environmental conditions of suspended samples. The insulation is based on a continuous cold/hot gas flow around the sample and thus does not require any additional isolation material. This provides a direct access to the levitated sample and circumvents any influence of the climate unit material to the running analyses.

  18. A new irradiation method with a neutron filter for silicon neutron transmutation doping at the Japan research reactor no. 3 (JRR-3).

    Science.gov (United States)

    Komeda, Masao; Kawasaki, Kozo; Obara, Toru

    2013-04-01

    We studied a new silicon irradiation holder with a neutron filter designed to make the vertical neutron flux profile uniform. Since an irradiation holder has to be made of a low activation material, we applied aluminum blended with B4C as the holder material. Irradiation methods to achieve uniform flux with a filter are discussed using Monte-Carlo calculation code MVP. Validation of the use of the MVP code for the holder's analyses is also discussed via characteristic experiments. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Calorimetric method of ac loss measurement in a rotating magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Ghoshal, P. K. [Oxford Instruments NanoScience, Abingdon, Oxfordshire OX13 5QX (United Kingdom); Coombs, T. A.; Campbell, A. M. [Department of Engineering, Electrical Engineering, University of Cambridge, Cambridge CB3 0FA (United Kingdom)

    2010-07-15

    A method is described for calorimetric ac-loss measurements of high-T{sub c} superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

  20. A Milliprobe for PIXE and PIGE Analysis used for the Study of Colour-Zoned Tourmaline

    Science.gov (United States)

    Mateus, R.; Alves, L. C.; Jesus, A. P.; Faria, A. F.; Ribeiro, J. P.

    2005-01-01

    A "milliprobe" system was implemented by using the focusing properties of a Van de Graaff accelerator, together with a collimator system including 1 mm diameter apertures, to impose the appropriate dimension to the beam spot. The scanning of the sample surface was achieved by X-Y movements of the sample holder (the Z axis being coincident with the beam direction). These movements were accomplished by a motorised X-Y table, with a travel of 25 mm × 25 mm, connected to the sample holder. This system was used to study specimens of the mineral tourmaline. Two samples, of the "watermelon" zoned tourmaline variety, originating from the Alto Ligonha pegmatite district in northern Mozambique, were analysed by the simultaneous use of PIXE (Proton-Induced X-Ray Emission) and PIGE (Proton-Induced Gamma-Ray Emission) techniques, in order to quantify their composition and try to establish a correlation between the elements (major and trace elements) and colour zoning. In order to validate the "milliprobe" analysis and study in more detail the frontier between zones of different colours, a microprobe analysis of the samples was also done. In this work, the mineralogical classification of the samples was accomplished. A correlation was established between the presence of Fe and green colour. It was also concluded that the presence of Mn by itself is not enough to lead to pink colour, which gives support to previous studies that claim that only Mn3+ and not the more common form Mn2+ is responsible for the pink colour.

  1. A Milliprobe for PIXE and PIGE Analysis used for the Study of Colour-Zoned Tourmaline

    Energy Technology Data Exchange (ETDEWEB)

    Mateus, R.; Alves, L.C.; Jesus, A.P.; Faria, A.F.; Ribeiro, J.P. [Univ. de Lisboa (Portugal). Centro de Fisica Nuclear

    2005-07-01

    A 'milliprobe' system was implemented by using the focusing properties of a Van de Graaff accelerator, together with a collimator system including 1mm diameter apertures, to impose the appropriate dimension to the beam spot. The scanning of the sample surface was achieved by X-Y movements of the sample holder (the Z axis being coincident with the beam direction). These movements were accomplished by a motorised X-Y table, with a travel of 25mmx25mm, connected to the sample holder. This system was used to study specimens of the mineral tourmaline. Two samples, of the 'watermelon' zoned tourmaline variety, originating from the Alto Ligonha pegmatite district in northern Mozambique, were analysed by the simultaneous use of PIXE (Proton-Induced X-Ray Emission) and PIGE (Proton-Induced Gamma-Ray Emission) techniques, in order to quantify their composition and try to establish a correlation between the elements (major and trace elements) and colour zoning. In order to validate the 'milliprobe' analysis and study in more detail the frontier between zones of different colours, a microprobe analysis of the samples was also done. In this work, the mineralogical classification of the samples was accomplished. A correlation was established between the presence of Fe and green colour. It was also concluded that the presence of Mn by itself is not enough to lead to pink colour, which gives support to previous studies that claim that only Mn{sup 3+} and not the more common form Mn{sup 2+} is responsible for the pink colour.

  2. Automatic grinding apparatus to control uniform specimen thicknesses

    Science.gov (United States)

    Bryner, Joseph S.

    1982-01-01

    This invention is directed to a new and improved grinding apparatus comprising (1) a movable grinding surface, (2) a specimen holder, (3) a displacing device for moving the holder and/or grinding surface toward one another, and (4) at least three devices for limiting displacement of the holder to the grinding surface.

  3. 78 FR 67129 - Procurement List; Proposed Additions and Deletions

    Science.gov (United States)

    2013-11-08

    ... List for production by the nonprofit agencies listed: Products NSN: 8455-00-NIB-0036--ID Card Holder, Dual Cards, Rigid Plastic, Black, W/Neck Lanyard. NSN: 8455-00-NIB-0037--ID Card Holder, Dual Cards, Rigid Plastic, Black. NSN: 8455-00-NIB-0039--Badge Holder, ID, Plastic, Clear, Waterproof W/Neck Lanyard...

  4. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  5. Boat sampling

    International Nuclear Information System (INIS)

    Citanovic, M.; Bezlaj, H.

    1994-01-01

    This presentation describes essential boat sampling activities: on site boat sampling process optimization and qualification; boat sampling of base material (beltline region); boat sampling of weld material (weld No. 4); problems accompanied with weld crown varieties, RPV shell inner radius tolerance, local corrosion pitting and water clarity. The equipment used for boat sampling is described too. 7 pictures

  6. A Bayesian Justification for Random Sampling in Sample Survey

    Directory of Open Access Journals (Sweden)

    Glen Meeden

    2012-07-01

    Full Text Available In the usual Bayesian approach to survey sampling the sampling design, plays a minimal role, at best. Although a close relationship between exchangeable prior distributions and simple random sampling has been noted; how to formally integrate simple random sampling into the Bayesian paradigm is not clear. Recently it has been argued that the sampling design can be thought of as part of a Bayesian's prior distribution. We will show here that under this scenario simple random sample can be given a Bayesian justification in survey sampling.

  7. Politics-Administration Interface and Sustenance of Public Service Ethos in South-West Nigeria

    Directory of Open Access Journals (Sweden)

    Salami Issa Afegbua

    2016-03-01

    Full Text Available This work examined politics-administration interface and the sustenance of public service ethos in Southwest Nigeria. Public servants and political functionaries in Southwest Nigeria are constantly in a struggle to fix each other in their pre-conceived mould of mental judgment which invariably breeds mutual suspicion, apprehension and setting the stage for conflict which is likely to impact negatively on the performance of public servants in Southwest Nigeria. The article identified the factors influencing the interface of public servants and political office holders in Southwest Nigeria. It also determined the influence of the interface between on public service ethos and finally examined the efforts made towards sustaining public service ethos in Southwest Nigeria. In carrying out this work, primary and secondary data were used. In the case of primary data, survey was carried out and questionnaire was used to elicit information from respondents in the Southwest geo-political zone of the country. Purposive random sampling techniques were adopted to determine the target respondents. The study has a sample of five hundred and thirty-five (535, which constitute 50 percent of the total population figure of 1070.  The findings revealed amongst others, that the synergy between political functionaries and public office holders is often characterized by both conflict and cooperation. In addition, there are certain factors influencing the interface of public servants and political office holders in Southwest Nigeria, these factors include: contract awards, consideration in the appointment of top civil servants etc. The study therefore, recommends the need for Southwest Nigeria to strengthen politics-administration interface in such a way that the public services in that region will be more productive. There is also the need for government in the Southwest to clarify the respective roles of political office holders and public servants. The principles

  8. 76 FR 16024 - Self-Regulatory Organizations; NYSE Amex LLC; Notice of Filing and Immediate Effectiveness of...

    Science.gov (United States)

    2011-03-22

    ... exchanges that may also adopt rules for QCCs, by making QCCs available to ATP Holders and their customers... proposes that when an NYSE Amex ATP Holder effects a QCT trade in a Regulation NMS Stock, that ATP Holder... respective counterparties or arranged for by a broker-dealer as principal or agent; (iii) the execution of...

  9. 77 FR 9277 - Self-Regulatory Organizations; NYSE Arca, Inc.; Notice of Filing and Immediate Effectiveness of...

    Science.gov (United States)

    2012-02-16

    ... and the Tracking Order Tier 1 Credit for ETP Holders and Market Makers February 10, 2012. Pursuant to... credit for ETP Holders and Market Makers. The text of the proposed rule change is available at the... credit \\3\\ and the Tracking Order \\4\\ Tier 1 credit for ETP Holders and Market Makers. The credits are...

  10. 38 CFR 36.4277 - Release of security.

    Science.gov (United States)

    2010-07-01

    ... payment of the indebtedness the holder shall not release a lien or other right in or to property held as..., the holder shall not release a lien under paragraph (a) of this section unless the consideration... released it shall be the holder's duty to acquire such lien on property of substantially equal value which...

  11. A novel tripod-driven platform for in-situ positioning of samples and electrical probes in a TEM

    International Nuclear Information System (INIS)

    Medford, B D; Rogers, B L; Laird, D; Berdunov, N; Beton, P H; Lockwood, A J; Gnanavel, T; Guan, W; Wang, J; Moebus, G; Inkson, B J

    2010-01-01

    We present a design for a novel coarse positioning system based on a tilting platform which is positioned using linear slip/stick motors. The design differs from common arrangements of stacked x, y, and z motors, and also ball mounted slip/stick motors, by allowing easy access along the central axis of the microscope holder. The drive motors are highly compact and co-linear and may be easily incorporated in an off-axis configuration, leaving a central cylindrical region with an approximate diameter of 3mm which is available to accommodate screened electrical wiring and optical fibres. We show that the tripod can be used to manoeuvre two metallic tips towards each other in-situ in a TEM in nanometre-scale lateral steps.

  12. High-speed crystal detection and characterization using a fast-readout detector.

    Science.gov (United States)

    Aishima, Jun; Owen, Robin L; Axford, Danny; Shepherd, Emma; Winter, Graeme; Levik, Karl; Gibbons, Paul; Ashton, Alun; Evans, Gwyndaf

    2010-09-01

    A novel raster-scanning method combining continuous sample translation with the fast readout of a Pilatus P6M detector has been developed on microfocus beamline I24 at Diamond Light Source. This fast grid-scan tool allows the rapid evaluation of large sample volumes without the need to increase the beam size at the sample through changes in beamline hardware. A slow version is available for slow-readout detectors. Examples of grid-scan use in centring optically invisible samples and in detecting and characterizing numerous microcrystals on a mesh-like holder illustrate the most common applications of the grid scan now in routine use on I24.

  13. Graph sampling

    OpenAIRE

    Zhang, L.-C.; Patone, M.

    2017-01-01

    We synthesise the existing theory of graph sampling. We propose a formal definition of sampling in finite graphs, and provide a classification of potential graph parameters. We develop a general approach of Horvitz–Thompson estimation to T-stage snowball sampling, and present various reformulations of some common network sampling methods in the literature in terms of the outlined graph sampling theory.

  14. Acceptance sampling using judgmental and randomly selected samples

    Energy Technology Data Exchange (ETDEWEB)

    Sego, Landon H.; Shulman, Stanley A.; Anderson, Kevin K.; Wilson, John E.; Pulsipher, Brent A.; Sieber, W. Karl

    2010-09-01

    We present a Bayesian model for acceptance sampling where the population consists of two groups, each with different levels of risk of containing unacceptable items. Expert opinion, or judgment, may be required to distinguish between the high and low-risk groups. Hence, high-risk items are likely to be identifed (and sampled) using expert judgment, while the remaining low-risk items are sampled randomly. We focus on the situation where all observed samples must be acceptable. Consequently, the objective of the statistical inference is to quantify the probability that a large percentage of the unsampled items in the population are also acceptable. We demonstrate that traditional (frequentist) acceptance sampling and simpler Bayesian formulations of the problem are essentially special cases of the proposed model. We explore the properties of the model in detail, and discuss the conditions necessary to ensure that required samples sizes are non-decreasing function of the population size. The method is applicable to a variety of acceptance sampling problems, and, in particular, to environmental sampling where the objective is to demonstrate the safety of reoccupying a remediated facility that has been contaminated with a lethal agent.

  15. In Situ Ptychography of Heterogeneous Catalysts using Hard X-Rays

    DEFF Research Database (Denmark)

    Baier, Sina; Damsgaard, Christian Danvad; Scholz, Maria

    2016-01-01

    A new closed cell is presented for in situ X-ray ptychography which allows studies under gas flow and at elevated temperature. In order to gain complementary information by transmission and scanning electron microscopy, the cell makes use of a Protochips E-chipTM which contains a small, thin...... the same sample holder for ex situ electron microscopy before and after the in situ study underlines the unique possibilities available with this combination of electron microscopy and X-ray microscopy on the same sample....

  16. 78 FR 17454 - Self-Regulatory Organizations; Chicago Board Options Exchange, Incorporated; Notice of Filing of...

    Science.gov (United States)

    2013-03-21

    ... generally may limit the life of a customer order to the period of normal market hours of 8:30 a.m. to 3:00 p... Trading Permit Holder shall use reasonable diligence to ascertain the best market for the subject security... Trading Permit Holder or person associated with a Trading Permit Holder has used ``reasonable diligence...

  17. 7 CFR Appendix I to Subpart E of... - Instructions for Loan Guarantees for Drought and Disaster Relief

    Science.gov (United States)

    2010-01-01

    ... discrepancy between the amount claimed by the Holder(s) and the information submitted by the Lender must be..., FmHA or its successor agency under Public Law 103-354 will pay the Holder only the amounts due the... liquidation of the loan. FmHA or its successor agency under Public Law 103-354 will agree to pay an estimated...

  18. 40 CFR 1065.245 - Sample flow meter for batch sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Sample flow meter for batch sampling... Sample flow meter for batch sampling. (a) Application. Use a sample flow meter to determine sample flow... difference between a diluted exhaust sample flow meter and a dilution air meter to calculate raw exhaust flow...

  19. Balanced sampling

    NARCIS (Netherlands)

    Brus, D.J.

    2015-01-01

    In balanced sampling a linear relation between the soil property of interest and one or more covariates with known means is exploited in selecting the sampling locations. Recent developments make this sampling design attractive for statistical soil surveys. This paper introduces balanced sampling

  20. Ensemble Sampling

    OpenAIRE

    Lu, Xiuyuan; Van Roy, Benjamin

    2017-01-01

    Thompson sampling has emerged as an effective heuristic for a broad range of online decision problems. In its basic form, the algorithm requires computing and sampling from a posterior distribution over models, which is tractable only for simple special cases. This paper develops ensemble sampling, which aims to approximate Thompson sampling while maintaining tractability even in the face of complex models such as neural networks. Ensemble sampling dramatically expands on the range of applica...

  1. The effect of thickness in the through-diffusion experiment

    International Nuclear Information System (INIS)

    Lehikoinen, J.; Uusheimo, K.; Valkiainen, M.

    1994-01-01

    The publication contains an experimental study of diffusion in the water filled pores of rock samples. The samples studied are rapakivi granite from Loviisa, southern Finland. The drill-core sample was sectioned perpendicularly with diamond saw and three cylinder formed samples were obtained. The nominal thicknesses (heights of the cylinders) are 2, 4 and 6 cm. For the diffusion measurement the sample holders were pressed between two chambers. One of the chambers was filled with 0.0044 molar sodium chloride solution spiked with tracers. Another chamber was filled with inactive solution. Tritium (HTO) considered to be water equivalent tracer and anionic 36 Cl were used as tracers. (9 refs., 19 figs., 2 tabs.)

  2. Modern survey sampling

    CERN Document Server

    Chaudhuri, Arijit

    2014-01-01

    Exposure to SamplingAbstract Introduction Concepts of Population, Sample, and SamplingInitial RamificationsAbstract Introduction Sampling Design, Sampling SchemeRandom Numbers and Their Uses in Simple RandomSampling (SRS)Drawing Simple Random Samples with and withoutReplacementEstimation of Mean, Total, Ratio of Totals/Means:Variance and Variance EstimationDetermination of Sample SizesA.2 Appendix to Chapter 2 A.More on Equal Probability Sampling A.Horvitz-Thompson EstimatorA.SufficiencyA.LikelihoodA.Non-Existence Theorem More Intricacies Abstract Introduction Unequal Probability Sampling StrategiesPPS Sampling Exploring Improved WaysAbstract Introduction Stratified Sampling Cluster SamplingMulti-Stage SamplingMulti-Phase Sampling: Ratio and RegressionEstimationviiviii ContentsControlled SamplingModeling Introduction Super-Population ModelingPrediction Approach Model-Assisted Approach Bayesian Methods Spatial SmoothingSampling on Successive Occasions: Panel Rotation Non-Response and Not-at-Homes Weighting Adj...

  3. Respondent-Driven Sampling – Testing Assumptions: Sampling with Replacement

    Directory of Open Access Journals (Sweden)

    Barash Vladimir D.

    2016-03-01

    Full Text Available Classical Respondent-Driven Sampling (RDS estimators are based on a Markov Process model in which sampling occurs with replacement. Given that respondents generally cannot be interviewed more than once, this assumption is counterfactual. We join recent work by Gile and Handcock in exploring the implications of the sampling-with-replacement assumption for bias of RDS estimators. We differ from previous studies in examining a wider range of sampling fractions and in using not only simulations but also formal proofs. One key finding is that RDS estimates are surprisingly stable even in the presence of substantial sampling fractions. Our analyses show that the sampling-with-replacement assumption is a minor contributor to bias for sampling fractions under 40%, and bias is negligible for the 20% or smaller sampling fractions typical of field applications of RDS.

  4. ECG movement artefacts can be greatly reduced with the aid of a movement absorbing device

    DEFF Research Database (Denmark)

    Harrison, Adrian Paul; Wandall, Kirsten; Thorball, Jørgen

    2007-01-01

    Accurate ECG signal analysis can be confounded by electric lead, and/or electrode movements varying in origin from, for example, hiccups, tremor or patient restlessness. ECG signals recorded using either a conventional electrode holder or with the aid of an electrode holder capable of absorbing...... movement artefacts, were measured on a healthy human subject. Results show a greatly improved stability of the ECG signal recorded using an electrode holder capable of absorbing movement artefacts during periods of lead disturbance, and highlight the movement artefacts that develop when the recording lead...... of a conventional ECG electrode holder is tugged or pulled during theperiod of monitoring. It is concluded that the new design of ECG electrode holder will not only enable clearer signal recordings for clinical assessment, but will reduce the ECG artefacts associated with the transportation of patients, and may...

  5. Grinding arrangement for ball nose milling cutters

    Science.gov (United States)

    Burch, C. F. (Inventor)

    1974-01-01

    A grinding arrangement for spiral fluted ball nose end mills and like tools includes a tool holder for positioning the tool relative to a grinding wheel. The tool is mounted in a spindle within the tool holder for rotation about its centerline and the tool holder is pivotably mounted for angular movement about an axis which intersects that centerline. A follower arm of a cam follower secured to the spindle cooperates with a specially shaped cam to provide rotation of the tool during the angular movement of the tool holder during the grinding cycle, by an amount determined by the cam profile. In this way the surface of the cutting edge in contact with the grinding wheel is maintained at the same height on the grinding wheel throughout the angular movement of the tool holder during the grinding cycle.

  6. Mechanical design of multiple zone plates precision alignment apparatus for hard X-ray focusing in twenty-nanometer scale

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Deming; Liu, Jie; Gleber, Sophie C.; Vila-Comamala, Joan; Lai, Barry; Maser, Jorg M.; Roehrig, Christian; Wojcik, Michael J.; Vogt, Franz Stefan

    2017-04-04

    An enhanced mechanical design of multiple zone plates precision alignment apparatus for hard x-ray focusing in a twenty-nanometer scale is provided. The precision alignment apparatus includes a zone plate alignment base frame; a plurality of zone plates; and a plurality of zone plate holders, each said zone plate holder for mounting and aligning a respective zone plate for hard x-ray focusing. At least one respective positioning stage drives and positions each respective zone plate holder. Each respective positioning stage is mounted on the zone plate alignment base frame. A respective linkage component connects each respective positioning stage and the respective zone plate holder. The zone plate alignment base frame, each zone plate holder and each linkage component is formed of a selected material for providing thermal expansion stability and positioning stability for the precision alignment apparatus.

  7. Development of a 170Tm source for mercury monitoring studies in humans using XRF

    International Nuclear Information System (INIS)

    Timmaraju, K. Phanisree; Fajurally, Bibi Najah; Armstrong, Andrea F.; Chettle, David R.

    2016-01-01

    The goals of the present study were to develop a 170 Tm radioisotope and generate a K XRF spectrum of mercury. Thulium foil and thulium oxide powder were both tested for impurities and the latter was found to be a better prospect for further studies. The 170 Tm radioisotope was developed from thulium oxide powder following the method of disolution and absorption. A suitable source holder and collimator were also designed based on Monte Carlo simulations. Using the radioisotope thus developed, a mercury XRF spectrum was successfully generated. - Highlights: • We tested the purity of thulium samples by XRF and NAA techniques. • Developed a procedure to generate Tm-170 isotope out of thulium oxide powder. • Designed a collimator and source holder • Generated XRF spectrum of mercury using the Tm-170 isotope. • Compared the highlights in mercury spectra from Tm-170 and Cd-109 isotopes.

  8. Sample preparation

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Sample preparation prior to HPLC analysis is certainly one of the most important steps to consider in trace or ultratrace analysis. For many years scientists have tried to simplify the sample preparation process. It is rarely possible to inject a neat liquid sample or a sample where preparation may not be any more complex than dissolution of the sample in a given solvent. The last process alone can remove insoluble materials, which is especially helpful with the samples in complex matrices if other interactions do not affect extraction. Here, it is very likely a large number of components will not dissolve and are, therefore, eliminated by a simple filtration process. In most cases, the process of sample preparation is not as simple as dissolution of the component interest. At times, enrichment is necessary, that is, the component of interest is present in very large volume or mass of material. It needs to be concentrated in some manner so a small volume of the concentrated or enriched sample can be injected into HPLC. 88 refs

  9. Specimen loading list for the varying temperature experiment

    International Nuclear Information System (INIS)

    Qualls, A.L.; Sitterson, R.G.

    1998-01-01

    The varying temperature experiment HFIR-RB-13J has been assembled and inserted in the reactor. Approximately 5300 specimens were cleaned, inspected, matched, and loaded into four specimen holders. A listing of each specimen loaded into the steady temperature holder, its position in the capsule, and the identification of the corresponding specimen loaded into the varying temperature holder is presented in this report

  10. 26 CFR 301.6323(e)-1 - Priority of interest and expenses.

    Science.gov (United States)

    2010-04-01

    ... interest is not subrogated to the rights of the holder of the State sales tax lien. However, if the holder...)-1, to the rights of the holder of the sales tax lien, he will also be entitled to any additional....6323(e)-1 Priority of interest and expenses. (a) In general. If the lien imposed by section 6321 is not...

  11. Sample summary report for ARG 1 pressure tube sample

    International Nuclear Information System (INIS)

    Belinco, C.

    2006-01-01

    The ARG 1 sample is made from an un-irradiated Zr-2.5% Nb pressure tube. The sample has 103.4 mm ID, 112 mm OD and approximately 500 mm length. A punch mark was made very close to one end of the sample. The punch mark indicates the 12 O'clock position and also identifies the face of the tube for making all the measurements. ARG 1 sample contains flaws on ID and OD surface. There was no intentional flaw within the wall of the pressure tube sample. Once the flaws are machined the pressure tube sample was covered from outside to hide the OD flaws. Approximately 50 mm length of pressure tube was left open at both the ends to facilitate the holding of sample in the fixtures for inspection. No flaw was machined in this zone of 50 mm on either end of the pressure tube sample. A total of 20 flaws were machined in ARG 1 sample. Out of these, 16 flaws were on the OD surface and the remaining 4 on the ID surface of the pressure tube. The flaws were characterized in to various groups like axial flaws, circumferential flaws, etc

  12. Fiber optical asssembly for fluorescence spectrometry

    Science.gov (United States)

    Piltch, Martin S.; Gray, Perry Clayton; Rubenstein, Richard

    2015-08-18

    System is provided for detecting the presence of an analyte of interest in a sample, said system comprising an elongated, transparent container for a sample; an excitation source in optical communication with the sample, wherein radiation from the excitation source is directed along the length of the sample, and wherein the radiation induces a signal which is emitted from the sample; and, at least two linear arrays disposed about the sample holder, each linear array comprising a plurality of optical fibers having a first end and a second end, wherein the first ends of the fibers are disposed along the length of the container and in proximity thereto; the second ends of the fibers of each array are bundled together to form a single end port.

  13. On the Calibration and Accuracy of the Guinier Camera for the Determination of Interplanar Spacings

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Manfred

    1962-03-15

    Equations describing the relative mean error in the determination of interplanar spacings have been theoretically deduced for transmission cameras and X-ray investigations with and without internal standard. Together with standard film exposures of known substances these equations may be used to determine once and for all the accuracy of a Guinier camera under different experimental conditions. This is shown for an 80 mm camera positioned asymmetrically to the incident beam ({alpha} = 30 deg). Pieces of Scotch tape were used as powder sample holders, and comparator measurements on k ({alpha}{sub 1} + {alpha}{sub 2}) spectra as well as rapid d-scale readings are discussed. It was found that a camera constant substantially independent of {theta} can be determined most accurately for any film with the aid of only a few calibration lines diffracted to high {theta} angles if for an optimal line measuring accuracy of {+-} 0. 01 mm the sample is never allowed to deviate by more than {+-} 0. 05 mm from the focussing cylinder defined by the film position. Using tape as sample holder, this condition can be fulfilled with a probability of at least 80 %. With thin glass slides on the other hand, the systematic error may be reduced so far that the use of internal standards after the primary calibration of a camera will appear unnecessary.

  14. Standardless quantification approach of TXRF analysis using fundamental parameter method

    International Nuclear Information System (INIS)

    Szaloki, I.; Taniguchi, K.

    2000-01-01

    New standardless evaluation procedure based on the fundamental parameter method (FPM) has been developed for TXRF analysis. The theoretical calculation describes the relationship between characteristic intensities and the geometrical parameters of the excitation, detection system and the specimen parameters: size, thickness, angle of the excitation beam to the surface and the optical properties of the specimen holder. Most of the TXRF methods apply empirical calibration, which requires the application of special preparation technique. However, the characteristic lines of the specimen holder (Si Kα,β) present information from the local excitation and geometrical conditions on the substrate surface. On the basis of the theoretically calculation of the substrate characteristic intensity the excitation beam flux can be approximated. Taking into consideration the elements are in the specimen material a system of non-linear equation can be given involving the unknown concentration values and the geometrical and detection parameters. In order to solve this mathematical problem PASCAL software was written, which calculates the sample composition and the average sample thickness by gradient algorithm. Therefore, this quantitative estimation of the specimen composition requires neither external nor internal standard sample. For verification of the theoretical calculation and the numerical procedure, several experiments were carried out using mixed standard solution containing elements of K, Sc, V, Mn, Co and Cu in 0.1 - 10 ppm concentration range. (author)

  15. Worldwide outdoor round robin study of organic photovoltaic devices and modules

    DEFF Research Database (Denmark)

    Madsen, Morten Vesterager; Gevorgyan, Suren; Pacios, R.

    2014-01-01

    Accurate characterization and reporting of organic photovoltaic (OPV) device performance remains one of the important challenges in the field. The large spread among the efficiencies of devices with the same structure reported by different groups is significantly caused by different procedures......-to-roll coated OPV cells and modules conducted among 46 laboratories worldwide is presented, where the samples and the testing equipment were integrated in a compact suitcase that served both as a sample transportation tool and as a holder and test equipment during testing. In addition, an internet based...

  16. Scanning tunnel microscope with large vision field compatible with a scanning electron microscope

    International Nuclear Information System (INIS)

    Volodin, A.P.; Stepanyan, G.A.; Khajkin, M.S.; Ehdel'man, V.S.

    1989-01-01

    A scanning tunnel microscope (STM) with the 20μm vision field and 1nm resolution, designed to be compatible with a scanning electron microscope (SEM), is described. The sample scanning area is chosen within the 3x10mm limits with a 0.1-1μm step. The STM needle is moved automatically toward the sample surface from the maximum distance of 10mm until the tunneling current appears. Bimorphous elements of the KP-1 piezocorrector are used in the STM design. The device is installed on a table of SEM object holders

  17. Enhanced conformational sampling using enveloping distribution sampling.

    Science.gov (United States)

    Lin, Zhixiong; van Gunsteren, Wilfred F

    2013-10-14

    To lessen the problem of insufficient conformational sampling in biomolecular simulations is still a major challenge in computational biochemistry. In this article, an application of the method of enveloping distribution sampling (EDS) is proposed that addresses this challenge and its sampling efficiency is demonstrated in simulations of a hexa-β-peptide whose conformational equilibrium encompasses two different helical folds, i.e., a right-handed 2.7(10∕12)-helix and a left-handed 3(14)-helix, separated by a high energy barrier. Standard MD simulations of this peptide using the GROMOS 53A6 force field did not reach convergence of the free enthalpy difference between the two helices even after 500 ns of simulation time. The use of soft-core non-bonded interactions in the centre of the peptide did enhance the number of transitions between the helices, but at the same time led to neglect of relevant helical configurations. In the simulations of a two-state EDS reference Hamiltonian that envelops both the physical peptide and the soft-core peptide, sampling of the conformational space of the physical peptide ensures that physically relevant conformations can be visited, and sampling of the conformational space of the soft-core peptide helps to enhance the transitions between the two helices. The EDS simulations sampled many more transitions between the two helices and showed much faster convergence of the relative free enthalpy of the two helices compared with the standard MD simulations with only a slightly larger computational effort to determine optimized EDS parameters. Combined with various methods to smoothen the potential energy surface, the proposed EDS application will be a powerful technique to enhance the sampling efficiency in biomolecular simulations.

  18. A Mechanism for Anonymous Credit Card Systems

    Science.gov (United States)

    Tamura, Shinsuke; Yanase, Tatsuro

    This paper proposes a mechanism for anonymous credit card systems, in which each credit card holder can conceal individual transactions from the credit card company, while enabling the credit card company to calculate the total expenditures of transactions of individual card holders during specified periods, and to identify card holders who executed dishonest transactions. Based on three existing mechanisms, i.e. anonymous authentication, blind signature and secure statistical data gathering, together with implicit transaction links proposed here, the proposed mechanism enables development of anonymous credit card systems without assuming any absolutely trustworthy entity like tamper resistant devices or organizations faithful both to the credit card company and card holders.

  19. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  20. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.