WorldWideScience

Sample records for sample depths ranged

  1. Extending the Effective Ranging Depth of Spectral Domain Optical Coherence Tomography by Spatial Frequency Domain Multiplexing

    Directory of Open Access Journals (Sweden)

    Tong Wu

    2016-11-01

    Full Text Available We present a spatial frequency domain multiplexing method for extending the imaging depth range of a spectral domain optical coherence tomography (SDOCT system without any expensive device. This method uses two galvo scanners with different pivot-offset distances in two independent reference arms for spatial frequency modulation and multiplexing. The spatial frequency contents corresponding to different depth regions of the sample can be shifted to different frequency bands. The spatial frequency domain multiplexing SDOCT system provides an approximately 1.9-fold increase in the effective ranging depth compared with that of a conventional full-range SDOCT system. The reconstructed images of phantom and biological tissue demonstrate the expected increase in ranging depth. The parameters choice criterion for this method is discussed.

  2. Influence of sampling depth and post-sampling analysis time on the ...

    African Journals Online (AJOL)

    Bacteriological analysis was carried out for samples taken at water depth and at 1, 6, 12 and 24 hours post-sampling. It was observed that the total and faecal coliform bacteria were significantly higher in the 3 m water depth samples than in the surface water samples (ANOVA, F = 59.41, 26.751, 9.82 (T.C); 46.41, 26.81, ...

  3. High resolution axicon-based endoscopic FD OCT imaging with a large depth range

    Science.gov (United States)

    Lee, Kye-Sung; Hurley, William; Deegan, John; Dean, Scott; Rolland, Jannick P.

    2010-02-01

    Endoscopic imaging in tubular structures, such as the tracheobronchial tree, could benefit from imaging optics with an extended depth of focus (DOF). This optics could accommodate for varying sizes of tubular structures across patients and along the tree within a single patient. In the paper, we demonstrate an extended DOF without sacrificing resolution showing rotational images in biological tubular samples with 2.5 μm axial resolution, 10 ìm lateral resolution, and > 4 mm depth range using a custom designed probe.

  4. A video-rate range sensor based on depth from defocus

    OpenAIRE

    Ghita, Ovidiu; Whelan, Paul F.

    2001-01-01

    Recovering the depth information derived from dynamic scenes implies real-time range estimation. This paper addresses the implementation of a bifocal range sensor which estimates the depth by measuring the relative blurring between two images captured with different focal settings. To recover the depth accurately even in cases when the scene is textureless, one possible solution is to project a structured light on the scene. As a consequence, in the scene's spectrum a spatial frequency derive...

  5. Sampling depth confounds soil acidification outcomes

    Science.gov (United States)

    In the northern Great Plains (NGP) of North America, surface sampling depths of 0-15 or 0-20 cm are suggested for testing soil characteristics such as pH. However, acidification is often most pronounced near the soil surface. Thus, sampling deeper can potentially dilute (increase) pH measurements an...

  6. Holobiont Diversity in a Reef-Building Coral over Its Entire Depth Range in the Mesophotic Zone

    Directory of Open Access Journals (Sweden)

    Fanny L. Gonzalez-Zapata

    2018-02-01

    Full Text Available Mesophotic reef-building coral communities (~30–120 m depth remain largely unexplored, despite representing roughly three-quarters of the overall depth range at which tropical coral reef ecosystems occur. Although many coral species are restricted to shallow depths, several species occur across large depth ranges, including lower mesophotic depths. Yet, it remains unclear how such species can persist under extreme low-light conditions and how the different symbiotic partners associated with these corals contribute to facilitate such broad depth ranges. We assessed holobiont genetic diversity of the Caribbean coral Agaricia undata over depth in three localities of Colombia: San Andres Island (between 37 and 85 m, Cartagena (between 17 and 45 m and “Parque Nacional Natural Corales de Profundidad” (between 77 and 87 m. We used a population genomics approach (NextRAD for the coral host, and amplicon sequencing for the associated Symbiodinium (non-coding region of the plastid psbA minicircle and prokaryotic (V4 region of the 16S rRNA gene symbiont community. For the coral host, genetic structuring was only observed across geographic regions, but not between depths. Bayesian clustering and discriminant analysis of principal components revealed genetic structuring between the three regions, but not between shallow (<30 m, upper (≥30 and ≤60 m and lower mesophotic (>60 m depths. This pattern was confirmed when evaluating pairwise differentiation (FST between populations, with much higher values between regions (0.0467–0.1034 compared to between depths [within location; −0.0075–(−0.0007]. Symbiotic partners, including seven types of zooxanthellae and 325 prokaryotic OTUs, did not exhibit partitioning across depths. All samples hosted Symbiodinium clade C3 and the type C3psbA_e was present in all depths. Alpha microbial diversity was not significantly different between zones (upper vs. lower, which community composition between coral

  7. Ascertaining depths for samples from hydrographic casts without CTD

    Digital Repository Service at National Institute of Oceanography (India)

    Narvekar, P.V.; Bhushan, R.; Somayajulu, B.L.K.

    A fairly extensive study was conducted in the Arabian Sea in April-May 1195 to ascertain sample depths without CTD. It is shown that depths (degrees 4000 m) derived using (1) only protected thermometer data, and (2) wire angle (degrees 35 degrees...

  8. Design compliance matrix waste sample container filling system for nested, fixed-depth sampling system

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    This design compliance matrix document provides specific design related functional characteristics, constraints, and requirements for the container filling system that is part of the nested, fixed-depth sampling system. This document addresses performance, external interfaces, ALARA, Authorization Basis, environmental and design code requirements for the container filling system. The container filling system will interface with the waste stream from the fluidic pumping channels of the nested, fixed-depth sampling system and will fill containers with waste that meet the Resource Conservation and Recovery Act (RCRA) criteria for waste that contains volatile and semi-volatile organic materials. The specifications for the nested, fixed-depth sampling system are described in a Level 2 Specification document (HNF-3483, Rev. 1). The basis for this design compliance matrix document is the Tank Waste Remediation System (TWRS) desk instructions for design Compliance matrix documents (PI-CP-008-00, Rev. 0)

  9. Tritium depth profiling in carbon samples from fusion experiments

    International Nuclear Information System (INIS)

    Friedrich, M.; Pilz, W.; Sun, G.; Behrisch, R.; Garcia-Rosales, C.; Bekris, N.; Penzhorn, R.-D.

    2000-01-01

    Tritium depth profiling by accelerator mass spectrometry has been performed at the Rossendorf 3 MV Tandetron. Tritium particles are counted after the accelerator using a semiconductor detector, while deuterium and other light elements are simultaneously measured with the Faraday cup between the injection magnet and the accelerator. Depth profiles have been measured in carbon samples cut from the first wall tiles of the Garching fusion experiment ASDEX-Upgrade and of the European fusion experiment JET, Culham/UK. Tritium contents in the JET samples were up to six orders higher than in samples from ASDEX-Upgrade. Tritium beam currents from samples with high tritium content were measured partly in the Faraday cup before the accelerator. A dedicated tritium AMS facility with an air-insulated 100 kV tandem accelerator is under construction

  10. Microbiome variation in corals with distinct depth distribution ranges across a shallow-mesophotic gradient (15-85 m)

    Science.gov (United States)

    Glasl, Bettina; Bongaerts, Pim; Elisabeth, Nathalie H.; Hoegh-Guldberg, Ove; Herndl, Gerhard J.; Frade, Pedro R.

    2017-06-01

    Mesophotic coral ecosystems (MCEs) are generally poorly studied, and our knowledge of lower MCEs (below 60 m depth) is largely limited to visual surveys. Here, we provide a first detailed assessment of the prokaryotic community associated with scleractinian corals over a depth gradient to the lower mesophotic realm (15-85 m). Specimens of three Caribbean coral species exhibiting differences in their depth distribution ranges ( Agaricia grahamae, Madracis pharensis and Stephanocoenia intersepta) were collected with a manned submersible on the island of Curaçao, and their prokaryotic communities assessed using 16S rRNA gene sequencing analysis. Corals with narrower depth distribution ranges (depth-specialists) were associated with a stable prokaryotic community, whereas corals with a broader niche range (depth-generalists) revealed a higher variability in their prokaryotic community. The observed depth effects match previously described patterns in Symbiodinium depth zonation. This highlights the contribution of structured microbial communities over depth to the coral's ability to colonize a broader depth range.

  11. Optimum water depth ranges of dominant submersed macrophytes in a natural freshwater lake.

    Science.gov (United States)

    Ye, Bibi; Chu, Zhaosheng; Wu, Aiping; Hou, Zeying; Wang, Shengrui

    2018-01-01

    Macrophytes show a zonal distribution along the lake littoral zone because of their specific preferred water depths while the optimum growth water depths of dominant submersed macrophytes in natural lakes are not well known. We studied the seasonal biomass and frequency patterns of dominant and companion submersed macrophytes along the water depth gradient in Lake Erhai in 2013. The results showed that the species richness and community biomass showed hump-back shaped patterns along the water depth gradient both in polydominant and monodominant communities. Biomass percentage of Potamogenton maackianus showed a hump-back pattern while biomass percentages of Ceratophyllum demersum and Vallisneria natans appeared U-shaped patterns across the water depth gradient in polydominant communities whereas biomass percentage of V. natans increased with the water depth in monodominant communities. Dominant species demonstrated a broader distribution range of water depth than companion species. Frequency and biomass of companion species declined drastically with the water depth whereas those of dominant species showed non-linear patterns across the water depth gradient. Namely, along the water depth gradient, biomass of P. maackianus and V. natans showed hump-back patterns and biomasses of C. demersum displayed a U-shaped pattern in the polydominant communities but biomass of V. natans demonstrated a hump-back pattern in the monodominant communities; frequency of P. maackianus showed a hump-back pattern and C. demersum and V. natans maintained high frequencies in the two types of communities. We can speculate that in Lake Erhai the optimum growth water depths of P. maackianus and C. demersum in the polydominant communities are 2.5-4.5 m and 1-2 m or 5-6 m, respectively and that of V. natans is 3-5 m in the polydominant communities and 2.5-5 m in the monodominant communities. This is the first report that the optimum water depth ranges in the horizontal direction of three

  12. Tritium depth profiling by AMS in carbon samples from fusion experiments

    International Nuclear Information System (INIS)

    Friedrich, M.; Pilz, W.; Sun, G.; Behrisch, R.; Garcia-Rosales, C.

    2001-01-01

    Tritium depth profiling measurements by accelerator mass spectrometry have been performed at a facility installed at the Rossendorf 3 MV Tandetron. In order to achieve an uniform erosion at the target surface inside of a commercial Cs ion sputtering source and to avoid edge effects, the samples were mechanically scanned inside of a commercial Cs sputter ion source. The sputtered negative ions were mass analysed by the injection magnet of the Tandetron. The tritium ions are counted after the acceleration with semiconductor detectors. Depth profiles have been measured for carbon samples which had been exposed to the plasma at the first wall of the Garching fusion experiment ASDEX-Upgrade and from the European fusion experiment JET, Culham/UK. A dedicated AMS facility with an air-insulated 100 kV tandem accelerator for depth profiling measurements at samples with high tritium concentration is under construction. First results of test operation are presented. (orig.)

  13. Mobile Variable Depth Sampling System Design Study

    International Nuclear Information System (INIS)

    BOGER, R.M.

    2000-01-01

    A design study is presented for a mobile, variable depth sampling system (MVDSS) that will support the treatment and immobilization of Hanford LAW and HLW. The sampler can be deployed in a 4-inch tank riser and has a design that is based on requirements identified in the Level 2 Specification (latest revision). The waste feed sequence for the MVDSS is based on Phase 1, Case 3S6 waste feed sequence. Technical information is also presented that supports the design study

  14. Mobile Variable Depth Sampling System Design Study

    Energy Technology Data Exchange (ETDEWEB)

    BOGER, R.M.

    2000-08-25

    A design study is presented for a mobile, variable depth sampling system (MVDSS) that will support the treatment and immobilization of Hanford LAW and HLW. The sampler can be deployed in a 4-inch tank riser and has a design that is based on requirements identified in the Level 2 Specification (latest revision). The waste feed sequence for the MVDSS is based on Phase 1, Case 3S6 waste feed sequence. Technical information is also presented that supports the design study.

  15. Depth-resolved sample composition analysis using laser-induced ablation-quadrupole mass spectrometry and laser-induced breakdown spectroscopy

    Science.gov (United States)

    Oelmann, J.; Gierse, N.; Li, C.; Brezinsek, S.; Zlobinski, M.; Turan, B.; Haas, S.; Linsmeier, Ch.

    2018-06-01

    Monitoring a sample's material composition became more and more important over the last years for both - industrial process control as well as for post mortem analysis in research and industrial development. Although material composition identification as well as a comparison with standard samples works fine, there is a lack of diagnostics which can provide quantitative information with depth resolution without any standard samples. We present a novel method utilizing a residual gas analysis with quadrupole mass spectrometry after picosecond laser-induced ablation and release of volatile species. In the present experiment, well characterized multilayer thin film solar cells (μc-Si:H and a-Si:D as p-i-n-junctions on ZnO:Al electrodes) are used as a set of well characterized material samples to demonstrate the capabilities of the new method. The linearity of the spectrometer signal to gas pressure simplifies its calibration and reduces its uncertainties in comparison with other analysis techniques, although high vacuum conditions (10-6 hPa to 10-7 hPa) are required to reach high sensitivity better than the percent-range. Moreover, the laser-ablation based sample analysis requires no preparation of the sample and is flexible regarding ablation rates. The application of a picosecond laser pulse ensures that the thermal penetration depth of the laser is in the same order of magnitude as the ablation rate, which enables to achieve depth resolutions in the order of 100 nm and avoids matrix mixing effects at the edge of the laser-induced crater in the sample.

  16. Deep permeability of the San Andreas Fault from San Andreas Fault Observatory at Depth (SAFOD) core samples

    Science.gov (United States)

    Morrow, Carolyn A.; Lockner, David A.; Moore, Diane E.; Hickman, Stephen H.

    2014-01-01

    The San Andreas Fault Observatory at Depth (SAFOD) scientific borehole near Parkfield, California crosses two actively creeping shear zones at a depth of 2.7 km. Core samples retrieved from these active strands consist of a foliated, Mg-clay-rich gouge containing porphyroclasts of serpentinite and sedimentary rock. The adjacent damage zone and country rocks are comprised of variably deformed, fine-grained sandstones, siltstones, and mudstones. We conducted laboratory tests to measure the permeability of representative samples from each structural unit at effective confining pressures, Pe up to the maximum estimated in situ Pe of 120 MPa. Permeability values of intact samples adjacent to the creeping strands ranged from 10−18 to 10−21 m2 at Pe = 10 MPa and decreased with applied confining pressure to 10−20–10−22 m2 at 120 MPa. Values for intact foliated gouge samples (10−21–6 × 10−23 m2 over the same pressure range) were distinctly lower than those for the surrounding rocks due to their fine-grained, clay-rich character. Permeability of both intact and crushed-and-sieved foliated gouge measured during shearing at Pe ≥ 70 MPa ranged from 2 to 4 × 10−22 m2 in the direction perpendicular to shearing and was largely insensitive to shear displacement out to a maximum displacement of 10 mm. The weak, actively-deforming foliated gouge zones have ultra-low permeability, making the active strands of the San Andreas Fault effective barriers to cross-fault fluid flow. The low matrix permeability of the San Andreas Fault creeping zones and adjacent rock combined with observations of abundant fractures in the core over a range of scales suggests that fluid flow outside of the actively-deforming gouge zones is probably fracture dominated.

  17. Intraspecific differences in lipid content of calanoid copepods across fine-scale depth ranges within the photic layer.

    Directory of Open Access Journals (Sweden)

    Margarita Zarubin

    Full Text Available Copepods are among the most abundant and diverse groups of mesozooplankton in the world's oceans. Each species has a certain depth range within which different individuals (of the same life stage and sex are found. Lipids are accumulated in many calanoid copepods for energy storage and reproduction. Lipid content in some species increases with depth, however studies so far focused mostly on temperate and high-latitude seasonal vertically migrating copepods and compared lipid contents among individuals either from coarse layers or between diapausing, deep-dwelling copepods and individuals found in the photic, near-surface layer. Here we examined whether lipid contents of individual calanoid copepods of the same species, life stage/sex differ between finer depth layers within the upper water column of subtropical and Arctic seas. A total of 6 calanoid species were collected from samples taken at precise depths within the photic layer in both cold eutrophic and warm oligotrophic environments using SCUBA diving, MOCNESS and Multinet. Measurements of lipid content were obtained from digitized photographs of the collected individuals. The results revealed significant differences in lipid content across depth differences as small as 12-15 meters for Mecynocera clausi C5 and Ctenocalanus vanus C5 (Red Sea, Clausocalanus furcatus males and two clausocalanid C5s (Mediterranean Sea, and Calanus glacialis C5 (Arctic. We suggest two possible explanations for the differences in lipid content with depth on such a fine scale: predator avoidance and buoyancy.

  18. Shave-off depth profiling: Depth profiling with an absolute depth scale

    International Nuclear Information System (INIS)

    Nojima, M.; Maekawa, A.; Yamamoto, T.; Tomiyasu, B.; Sakamoto, T.; Owari, M.; Nihei, Y.

    2006-01-01

    Shave-off depth profiling provides profiling with an absolute depth scale. This method uses a focused ion beam (FIB) micro-machining process to provide the depth profile. We show that the shave-off depth profile of a particle reflected the spherical shape of the sample and signal intensities had no relationship to the depth. Through the introduction of FIB micro-sampling, the shave-off depth profiling of a dynamic random access memory (DRAM) tip was carried out. The shave-off profile agreed with a blue print from the manufacturing process. Finally, shave-off depth profiling is discussed with respect to resolutions and future directions

  19. Sub-keV secondary ion mass spectrometry depth profiling: comparison of sample rotation and oxygen flooding

    International Nuclear Information System (INIS)

    Liu, R.; Wee, A.T.S.

    2004-01-01

    Following the increasingly stringent requirements in the characterization of sub-micron IC devices, an understanding of the various factors affecting ultra shallow depth profiling in secondary ion mass spectrometry (SIMS) has become crucial. Achieving high depth resolution (of the order of 1 nm) is critical in the semiconductor industry today, and various methods have been developed to optimize depth resolution. In this paper, we will discuss ultra shallow SIMS depth profiling using B and Ge delta-doped Si samples using low energy 0.5 keV O 2 + primary beams. The relationship between depth resolution of the delta layers and surface topography measured by atomic force microscopy (AFM) is studied. The effect of oxygen flooding and sample rotation, used to suppress surface roughening is also investigated. Oxygen flooding was found to effectively suppress roughening and gives the best depth resolution for B, but sample rotation gives the best resolution for Ge. Possible mechanisms for this are discussed

  20. Influence of the kind of peat and the depth of sampling on the biochemical properties of Tagan peatland

    Science.gov (United States)

    Wojciech Szajdak, Lech; Inisheva, Lydia I.

    2010-05-01

    The upper layer of a peat bog in which organic matter decomposes aerobically much more rapidly than in the underlying, anaerobic catotelm. As litter accumulates at the surface the size of the catotelm increases, because the thickness of the acrotelm is limited to depth at which aerobic respiration can occur. Although the rate of decomposition per unit volume of material is much greater in the acrotelm than in the catotelm, a point is reached at which the difference in volume between the two layers is such that the total rate of decomposition in the catotelm is equal to that in the acrotelm. This limits the thickness to which the bog can grow. Should there be a climate change (e.g. an increase in precipitation) growth can resume. Bogs therefore preserve a record of climatic conditions. Soils samples were taken from four places marked as No 1, 2, 3 and 4 each from two depth 0-25 and 50-75 cm of the peatland Tagan. Peatlands Tagan is located near Tomsk, West Siberia, Russia. Place No 1 in both layers represents grasses peat with the degree of the decomposition ranged from 25 to 35% (pH 6.31-7.95). Point 2 is characterized by wooden and wooden grasses peat with 35% degree of the decomposition (pH 5.16-9.31. There is buckbean peat in the points 3 and 4 (pH 6.4-6.49). However, 1.5 m depth of sapropel is located in point 4. The activity of the following enzymes: xanthine oxidase, phenolic oxidase, peroxidase, urease, nitrate reductase were measured and two forms of organic carbon (total organic carbon and dissolved organic carbon) and two form of iron Fe(II) and Fe(III) were determined in these samples. These enzymes participate in several biochemical pathways in soil connected with redox potential. The concentrations of indole-3-acetic acid, very famous fitohormone were also measured. It was observed in all places of sampling significant increase of the total organic carbon with an increase of the depth. However, the quantity of dissolved organic carbon closely decreased

  1. Genre Differences on Visual Perception of Color Range and Depth of Field

    Directory of Open Access Journals (Sweden)

    Luisa Ballesteros

    2003-07-01

    Full Text Available Visual perception is the result of the integration of various related factors of the observed object and its environment. In this study we evaluated the impact of tridimensional form on color perception and the angle from the horizontal plane of a set of similar objets on the depth of field perception between young men and women. A panel half magenta and half white placed at the end of a black box, folded either concaved or convexed to alter the chromatic effect perceived were used to determine tridimensional form on color perception. Four sets of identical sticks where the angle from the horizontal plane varied for each, were used to determine the effect of spatial distribution of depth of field perception. The parameters taking into account were age, genre, associated visual defects for each individual evaluated. Our results show that the tridimensional form alters color perception but the range of color perceived was larger for women whereas depending on the angle from the horizontal plane we found genre differences on the depth of field perception.

  2. Probe depth matters in dermal microdialysis sampling of benzoic acid after topical application

    DEFF Research Database (Denmark)

    Holmgaard, R; Benfeldt, E; Bangsgaard, N

    2012-01-01

    -2 mm) and deep (>2 mm) positioning of the linear MD probe in the dermis of human abdominal skin, followed by topical application of 4 mg/ml of benzoic acid (BA) in skin chambers overlying the probes. Dialysate was sampled every hour for 12 h and analysed for BA content by high-performance liquid...... chromatography. Probe depth was measured by 20-MHz ultrasound scanning. The area under the time-versus-concentration curve (AUC) describes the drug exposure in the tissue during the experiment and is a relevant parameter to compare for the 3 dermal probe depths investigated. The AUC(0-12) were: superficial...... significantly different from each other (p value paper demonstrates that there is an inverse relationship between the depth of the probe in the dermis and the amount of drug sampled following topical penetration ex vivo. The result is of relevance to the in vivo situation, and it can...

  3. Micro-Raman depth profile investigations of beveled Al+-ion implanted 6H-SiC samples

    International Nuclear Information System (INIS)

    Zuk, J.; Romanek, J.; Skorupa, W.

    2009-01-01

    6H-SiC single crystals were implanted with 450 keV Al + -ions to a fluence of 3.4 x 10 15 cm -2 , and in a separate experiment subjected to multiple Al + implantations with the four energies: 450, 240, 115 and 50 keV and different fluences to obtain rectangular-like depth distributions of Al in SiC. The implantations were performed along [0 0 0 1] channeling and non-channeling ('random') directions. Subsequently, the samples were annealed for 10 min at 1650 deg. C in an argon atmosphere. The depth profiles of the implanted Al atoms were obtained by secondary ion mass spectrometry (SIMS). Following implantation and annealing, the samples were beveled by mechanical polishing. Confocal micro-Raman spectroscopic investigations were performed with a 532 nm wavelength laser beam of a 1 μm focus diameter. The technique was used to determine precisely the depth profiles of TO and LO phonon lines intensity in the beveled samples to a depth of about 2000 nm. Micro-Raman spectroscopy was also found to be useful in monitoring very low levels of disorder remaining in the Al + implanted and annealed 6H-SiC samples. The micro-Raman technique combined with sample beveling also made it possible the determination of optical absorption coefficient profiles in implanted subsurface layers.

  4. Extended depth measurement for a Stokes sample imaging polarimeter

    Science.gov (United States)

    Dixon, Alexander W.; Taberner, Andrew J.; Nash, Martyn P.; Nielsen, Poul M. F.

    2018-02-01

    A non-destructive imaging technique is required for quantifying the anisotropic and heterogeneous structural arrangement of collagen in soft tissue membranes, such as bovine pericardium, which are used in the construction of bioprosthetic heart valves. Previously, our group developed a Stokes imaging polarimeter that measures the linear birefringence of samples in a transmission arrangement. With this device, linear retardance and optic axis orientation; can be estimated over a sample using simple vector algebra on Stokes vectors in the Poincaré sphere. However, this method is limited to a single path retardation of a half-wave, limiting the thickness of samples that can be imaged. The polarimeter has been extended to allow illumination of narrow bandwidth light of controllable wavelength through achromatic lenses and polarization optics. We can now take advantage of the wavelength dependence of relative retardation to remove ambiguities that arise when samples have a single path retardation of a half-wave to full-wave. This effectively doubles the imaging depth of this method. The method has been validated using films of cellulose of varied thickness, and applied to samples of bovine pericardium.

  5. Preliminary level 2 specification for the nested, fixed-depth sampling system

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    This preliminary Level 2 Component Specification establishes the performance, design, development, and test requirements for the in-tank sampling system which will support the BNFL contract in the final disposal of Hanford's High Level Wastes (HLW) and Low Activity Wastes (LAW). The PHMC will provide Low Activity Wastes (LAW) tank wastes for final treatment by BNFL from double-shell feed tanks. Concerns about the inability of the baseline ''grab'' sampling to provide large volume samples within time constraints has led to the development of a nested, fixed-depth sampling system. This sampling system will provide large volume? representative samples without the environmental, radiation exposure, and sample volume Impacts of the current base-line ''grab'' sampling method. This preliminary Level 2 Component Specification is not a general specification for tank sampling, but is based on a ''record of decision'', AGA (HNF-SD-TWR-AGA-001 ), the System Specification for the Double Shell Tank System (HNF-SD-WM-TRD-O07), and the BNFL privatization contract

  6. Detour factors in water and plastic phantoms and their use for range and depth scaling in electron-beam dosimetry

    International Nuclear Information System (INIS)

    Fernandez-Varea, J.M.; Andreo, P.; Tabata, T.

    1996-01-01

    Average penetration depths and detour factors of 1-50 MeV electrons in water and plastic materials have been computed by means of analytical calculation, within the continuous-slowing-down approximation and including multiple scattering, and using the Monte Carlo codes ITS and PENELOPE. Results are compared to detour factors from alternative definitions previously proposed in the literature. Different procedures used in low-energy electron-beam dosimetry to convert ranges and depths measured in plastic phantoms into water-equivalent ranges and depths are analysed. A new simple and accurate scaling method, based on Monte Carlo-derived ratios of average electron penetration depths and thus incorporating the effect of multiple scattering, is presented. Data are given for most plastics used in electron-beam dosimetry together with a fit which extends the method to any other low-Z plastic material. A study of scaled depth - dose curves and mean energies as a function of depth for some plastics of common usage shows that the method improves the consistency and results of other scaling procedures in dosimetry with electron beams at therapeutic energies. (author)

  7. Variation in coral growth rates with depth at Discovery Bay, Jamaica

    Energy Technology Data Exchange (ETDEWEB)

    Huston, M

    1985-01-01

    Growth rates, determined by X-radiographic measurement of skeletal extension, decreased with depth for four of six species of coral examined at Discovery Bay, Jamaica. Growth of Porites astreoides, Montastrea annularis, Colpophyllia natans, and Siderastrea siderea decreased significantly with depth over a 1- to 30-m depth range. In Montastrea cavernosa, the highest growth rate occurred in the middle of the sampled depth range. Agaricia agaricites had no measurable change in growth rate with depth. A compilation of available growth data for Atlantic and Pacific corals shows a strong pattern of highest growth rates a short distance below the surface and a decrease with depth.

  8. Depth profiling of residual activity of ^{237}U fragments as a range verification technique for ^{238}U primary ion beam

    Directory of Open Access Journals (Sweden)

    I. Strašík

    2012-07-01

    Full Text Available Experimental and simulation data concerning fragmentation of ^{238}U ion beam in aluminum, copper, and stainless-steel targets with the initial energy 500 and 950  MeV/u are collected in the paper. A range-verification technique based on depth profiling of residual activity is presented. The irradiated targets were constructed in the stacked-foil geometry and analyzed using gamma-ray spectroscopy. One of the purposes of these experiments was depth profiling of residual activity of induced nuclides and projectile fragments. Among the projectile fragments, special attention is paid to the ^{237}U isotope that has a range very close to the range of the primary ^{238}U ions. Therefore, the depth profiling of the ^{237}U isotope can be utilized for experimental verification of the ^{238}U primary-beam range, which is demonstrated and discussed in the paper. The experimental data are compared with computer simulations by FLUKA, SRIM, and ATIMA, as well as with complementary experiments.

  9. Corals through the light : phylogenetics, functional diversity and adaptive strategies of coral-symbiont associations over a large depth range

    NARCIS (Netherlands)

    Rodrigues Frade, P.

    2009-01-01

    Light constitutes the main energy source in the coral reef ecosystem, with its intensity dramatically reduced with increasing depth over the reef slope. How do corals thrive across these acute light gradients that exist over large depth ranges? This and many more questions are addressed throughout

  10. Depth Distribution Studies of Carbon in Steel Surfaces by Means of Charged Particle Activation Analysis with an Account of Heat and Diffusion Effects in the Sample

    Energy Technology Data Exchange (ETDEWEB)

    Brune, D; Lorenzen, J [AB Atomenergi, Nykoeping (Sweden); Witalis, E [Swedish National Defence Research Inst., Stockholm (Sweden)

    1972-05-15

    Depth distribution studies of carbon in steel and iron were carried out in the concentration range 0.05-1 %, using proton activation analysis. Surface content studies were performed in the concentration range 0.01-1 % using deuteron activation analysis. The following reactions were utilized: {sup 12}C(p,{gamma}){sup 13}N and {sup 12}C(d,n){sup 13}N Evaluations of depth distribution were based on resonances in the excitation function. The carbon content was determined with the aid of the positron emitter, {sup 13}N, using either single-peak or coincidence measurements. The heat dissipation in the irradiated region of the samples was calculated, and the temperature rise was measured using thermocouples. The temperature distribution within the hot zone subjected to irradiation by charged particles, together with the temperature distribution around this zone, was studied in order to estimate any effect this might have on the carbon diffusion. A device for automatic sample exchange which is remotely controlled is described.

  11. Depth Distribution Studies of Carbon in Steel Surfaces by Means of Charged Particle Activation Analysis with an Account of Heat and Diffusion Effects in the Sample

    International Nuclear Information System (INIS)

    Brune, D.; Lorenzen, J.; Witalis, E.

    1972-05-01

    Depth distribution studies of carbon in steel and iron were carried out in the concentration range 0.05-1 %, using proton activation analysis. Surface content studies were performed in the concentration range 0.01-1 % using deuteron activation analysis. The following reactions were utilized: 12 C(p,γ) 13 N and 12 C(d,n) 13 N Evaluations of depth distribution were based on resonances in the excitation function. The carbon content was determined with the aid of the positron emitter, 13 N, using either single-peak or coincidence measurements. The heat dissipation in the irradiated region of the samples was calculated, and the temperature rise was measured using thermocouples. The temperature distribution within the hot zone subjected to irradiation by charged particles, together with the temperature distribution around this zone, was studied in order to estimate any effect this might have on the carbon diffusion. A device for automatic sample exchange which is remotely controlled is described

  12. Effects of GPS sampling intensity on home range analyses

    Science.gov (United States)

    Jeffrey J. Kolodzinski; Lawrence V. Tannenbaum; David A. Osborn; Mark C. Conner; W. Mark Ford; Karl V. Miller

    2010-01-01

    The two most common methods for determining home ranges, minimum convex polygon (MCP) and kernel analyses, can be affected by sampling intensity. Despite prior research, it remains unclear how high-intensity sampling regimes affect home range estimations. We used datasets from 14 GPS-collared, white-tailed deer (Odocoileus virginianus) to describe...

  13. Depth sensitivity of Lexan polycarbonate detector

    CERN Document Server

    Awad, E M

    1999-01-01

    The dependence of the registration sensitivity of Lexan polycarbonate with depth inside the detector was studied. Samples of Lexan from General Electric were irradiated to two long range ions. These were Ni and Au ions with a projectile energy of 0.3 and 1 GeV/n. Two independent techniques, the track-diameter technique (TDT) and the track profile technique (TPT), were used. The registration sensitivity was measured at depths of 7, 10, 15, 18, 20, 28, 35 and 40 mu m inside the detector. The results of the two techniques show that the detector sensitivity decreases gradually with the depth inside the detector. It reaches 20 % less compared to sensitivity at the surface after 40 mu m have been removed.

  14. Non-uniform sampling and wide range angular spectrum method

    International Nuclear Information System (INIS)

    Kim, Yong-Hae; Byun, Chun-Won; Oh, Himchan; Lee, JaeWon; Pi, Jae-Eun; Heon Kim, Gi; Lee, Myung-Lae; Ryu, Hojun; Chu, Hye-Yong; Hwang, Chi-Sun

    2014-01-01

    A novel method is proposed for simulating free space field propagation from a source plane to a destination plane that is applicable for both small and large propagation distances. The angular spectrum method (ASM) was widely used for simulating near field propagation, but it caused a numerical error when the propagation distance was large because of aliasing due to under sampling. Band limited ASM satisfied the Nyquist condition on sampling by limiting a bandwidth of a propagation field to avoid an aliasing error so that it could extend the applicable propagation distance of the ASM. However, the band limited ASM also made an error due to the decrease of an effective sampling number in a Fourier space when the propagation distance was large. In the proposed wide range ASM, we use a non-uniform sampling in a Fourier space to keep a constant effective sampling number even though the propagation distance is large. As a result, the wide range ASM can produce simulation results with high accuracy for both far and near field propagation. For non-paraxial wave propagation, we applied the wide range ASM to a shifted destination plane as well. (paper)

  15. The effect of short-range spatial variability on soil sampling uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Perk, Marcel van der [Department of Physical Geography, Utrecht University, P.O. Box 80115, 3508 TC Utrecht (Netherlands)], E-mail: m.vanderperk@geo.uu.nl; De Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria [Agenzia per la Protezione dell' Ambiente e per i Servizi Tecnici (APAT), Servizio Laboratori, Misure ed Attivita di Campo, Via di Castel Romano, 100-00128 Roma (Italy); Fajgelj, Ales; Sansone, Umberto [International Atomic Energy Agency (IAEA), Agency' s Laboratories Seibersdorf, A-1400 Vienna (Austria); Jeran, Zvonka; Jacimovic, Radojko [Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia)

    2008-11-15

    This paper aims to quantify the soil sampling uncertainty arising from the short-range spatial variability of elemental concentrations in the topsoils of agricultural, semi-natural, and contaminated environments. For the agricultural site, the relative standard sampling uncertainty ranges between 1% and 5.5%. For the semi-natural area, the sampling uncertainties are 2-4 times larger than in the agricultural area. The contaminated site exhibited significant short-range spatial variability in elemental composition, which resulted in sampling uncertainties of 20-30%.

  16. The effect of short-range spatial variability on soil sampling uncertainty.

    Science.gov (United States)

    Van der Perk, Marcel; de Zorzi, Paolo; Barbizzi, Sabrina; Belli, Maria; Fajgelj, Ales; Sansone, Umberto; Jeran, Zvonka; Jaćimović, Radojko

    2008-11-01

    This paper aims to quantify the soil sampling uncertainty arising from the short-range spatial variability of elemental concentrations in the topsoils of agricultural, semi-natural, and contaminated environments. For the agricultural site, the relative standard sampling uncertainty ranges between 1% and 5.5%. For the semi-natural area, the sampling uncertainties are 2-4 times larger than in the agricultural area. The contaminated site exhibited significant short-range spatial variability in elemental composition, which resulted in sampling uncertainties of 20-30%.

  17. Sampling Number Effects in 2D and Range Imaging of Range-gated Acquisition

    International Nuclear Information System (INIS)

    Kwon, Seong-Ouk; Park, Seung-Kyu; Baik, Sung-Hoon; Cho, Jai-Wan; Jeong, Kyung-Min

    2015-01-01

    In this paper, we analyzed the number effects of sampling images for making a 2D image and a range image from acquired RGI images. We analyzed the number effects of RGI images for making a 2D image and a range image using a RGI vision system. As the results, 2D image quality was not much depended on the number of sampling images but on how much well extract efficient RGI images. But, the number of RGI images was important for making a range image because range image quality was proportional to the number of RGI images. Image acquiring in a monitoring area of nuclear industry is an important function for safety inspection and preparing appropriate control plans. To overcome the non-visualization problem caused by airborne obstacle particles, vision systems should have extra-functions, such as active illumination lightening through disturbance airborne particles. One of these powerful active vision systems is a range-gated imaging system. The vision system based on the range-gated imaging system can acquire image data from raining or smoking environments. Range-gated imaging (RGI) is a direct active visualization technique using a highly sensitive image sensor and a high intensity illuminant. Currently, the range-gated imaging technique providing 2D and 3D images is one of emerging active vision technologies. The range-gated imaging system gets vision information by summing time sliced vision images. In the RGI system, a high intensity illuminant illuminates for ultra-short time and a highly sensitive image sensor is gated by ultra-short exposure time to only get the illumination light. Here, the illuminant illuminates objects by flashing strong light through airborne disturbance particles. Thus, in contrast to passive conventional vision systems, the RGI active vision technology robust for low-visibility environments

  18. Sampling Number Effects in 2D and Range Imaging of Range-gated Acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Seong-Ouk; Park, Seung-Kyu; Baik, Sung-Hoon; Cho, Jai-Wan; Jeong, Kyung-Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In this paper, we analyzed the number effects of sampling images for making a 2D image and a range image from acquired RGI images. We analyzed the number effects of RGI images for making a 2D image and a range image using a RGI vision system. As the results, 2D image quality was not much depended on the number of sampling images but on how much well extract efficient RGI images. But, the number of RGI images was important for making a range image because range image quality was proportional to the number of RGI images. Image acquiring in a monitoring area of nuclear industry is an important function for safety inspection and preparing appropriate control plans. To overcome the non-visualization problem caused by airborne obstacle particles, vision systems should have extra-functions, such as active illumination lightening through disturbance airborne particles. One of these powerful active vision systems is a range-gated imaging system. The vision system based on the range-gated imaging system can acquire image data from raining or smoking environments. Range-gated imaging (RGI) is a direct active visualization technique using a highly sensitive image sensor and a high intensity illuminant. Currently, the range-gated imaging technique providing 2D and 3D images is one of emerging active vision technologies. The range-gated imaging system gets vision information by summing time sliced vision images. In the RGI system, a high intensity illuminant illuminates for ultra-short time and a highly sensitive image sensor is gated by ultra-short exposure time to only get the illumination light. Here, the illuminant illuminates objects by flashing strong light through airborne disturbance particles. Thus, in contrast to passive conventional vision systems, the RGI active vision technology robust for low-visibility environments.

  19. Long-range depth profiling of camouflaged targets using single-photon detection

    Science.gov (United States)

    Tobin, Rachael; Halimi, Abderrahim; McCarthy, Aongus; Ren, Ximing; McEwan, Kenneth J.; McLaughlin, Stephen; Buller, Gerald S.

    2018-03-01

    We investigate the reconstruction of depth and intensity profiles from data acquired using a custom-designed time-of-flight scanning transceiver based on the time-correlated single-photon counting technique. The system had an operational wavelength of 1550 nm and used a Peltier-cooled InGaAs/InP single-photon avalanche diode detector. Measurements were made of human figures, in plain view and obscured by camouflage netting, from a stand-off distance of 230 m in daylight using only submilliwatt average optical powers. These measurements were analyzed using a pixelwise cross correlation approach and compared to analysis using a bespoke algorithm designed for the restoration of multilayered three-dimensional light detection and ranging images. This algorithm is based on the optimization of a convex cost function composed of a data fidelity term and regularization terms, and the results obtained show that it achieves significant improvements in image quality for multidepth scenarios and for reduced acquisition times.

  20. Health risk assessment of drinking arsenic-containing groundwater in Hasilpur, Pakistan: effect of sampling area, depth, and source.

    Science.gov (United States)

    Tabassum, Riaz Ahmad; Shahid, Muhammad; Dumat, Camille; Niazi, Nabeel Khan; Khalid, Sana; Shah, Noor Samad; Imran, Muhammad; Khalid, Samina

    2018-02-10

    Currently, several news channels and research publications have highlighted the dilemma of arsenic (As)-contaminated groundwater in Pakistan. However, there is lack of data regarding groundwater As content of various areas in Pakistan. The present study evaluated As contamination and associated health risks in previously unexplored groundwater of Hasilpur-Pakistan. Total of 61 groundwater samples were collected from different areas (rural and urban), sources (electric pump, hand pump, and tubewell) and depths (35-430 ft or 11-131 m). The water samples were analyzed for As level and other parameters such as pH, electrical conductivity, total dissolved solids, cations, and anions. It was found that 41% (25 out of 61) water samples contained As (≥ 5 μg/L). Out of 25 As-contaminated water samples, 13 water samples exceeded the permissible level of WHO (10 μg/L). High As contents have been found in tubewell samples and at high sampling depths (> 300 ft). The major As-contaminated groundwater in Hasilpur is found in urban areas. Furthermore, health risk and cancer risk due to As contamination were also assessed with respect to average daily dose (ADD), hazard quotient (HQ), and carcinogenic risk (CR). The values of HQ and CR of As in Hasilpur were up to 58 and 0.00231, respectively. Multivariate analysis revealed a positive correlation between groundwater As contents, pH, and depth in Hasilpur. The current study proposed the proper monitoring and management of well water in Hasilpur to minimize the As-associated health hazards.

  1. 10.23  Mcps laser pseudo-code ranging system with 0.33  mm (1σ) pseudo-range measurement precision.

    Science.gov (United States)

    Yu, Xiaonan; Tong, Shoufeng; Zhang, Lei; Dong, Yan; Zhao, Xin; Qiao, Yue

    2017-07-01

    The inter-satellite laser link is the backbone of the next inter-satellite information network, and ranging and communication are the main functions of the inter-satellite laser link. This study focuses on the inter-satellite laser ranging based on the pseudo-code correlation technology. In this paper, several typical laser-ranging methods have been compared and we determined that the laser pseudo-code ranging architecture is more suitable for the inter-satellite laser communication link. The pseudo-code ranging system is easy to combine with a digital communication system, and we used it to calculate integer ambiguity by modulating the time information. The main challenge of the ranging system is range precision, which is the main focus of this paper. First, the framework of the pseudo-code ranging system is introduced; the ranging architecture of dual one-way ranging is used to eliminate the clock error between the two transceivers, and then the uncertainty of the phase detector is analyzed. In the analysis, the carrier to noise ratio and the ranging code rate are constrained by the laser communication link margin and the electronic hardware limitation. Therefore, the relationship between the sampling depth and the phase detector uncertainty is verified. A series of optical fiber channel laser pseudo-code ranging experiments demonstrated the effects of sampling depth on the ranging precision. By adjusting the depth of storage, such as the depth of 1.6 Mb, we obtained a pseudo-range measurement precision of 0.33 mm (1σ), which is equivalent to 0.0001 times code subdivision of 10.23 Mcps pseudo-code. This paper has achieved high precision in a pseudo-range measurements, which is the foundation of the inter-satellite laser link.

  2. Determining Plane-Sweep Sampling Points in Image Space Using the Cross-Ratio for Image-Based Depth Estimation

    Science.gov (United States)

    Ruf, B.; Erdnuess, B.; Weinmann, M.

    2017-08-01

    With the emergence of small consumer Unmanned Aerial Vehicles (UAVs), the importance and interest of image-based depth estimation and model generation from aerial images has greatly increased in the photogrammetric society. In our work, we focus on algorithms that allow an online image-based dense depth estimation from video sequences, which enables the direct and live structural analysis of the depicted scene. Therefore, we use a multi-view plane-sweep algorithm with a semi-global matching (SGM) optimization which is parallelized for general purpose computation on a GPU (GPGPU), reaching sufficient performance to keep up with the key-frames of input sequences. One important aspect to reach good performance is the way to sample the scene space, creating plane hypotheses. A small step size between consecutive planes, which is needed to reconstruct details in the near vicinity of the camera may lead to ambiguities in distant regions, due to the perspective projection of the camera. Furthermore, an equidistant sampling with a small step size produces a large number of plane hypotheses, leading to high computational effort. To overcome these problems, we present a novel methodology to directly determine the sampling points of plane-sweep algorithms in image space. The use of the perspective invariant cross-ratio allows us to derive the location of the sampling planes directly from the image data. With this, we efficiently sample the scene space, achieving higher sampling density in areas which are close to the camera and a lower density in distant regions. We evaluate our approach on a synthetic benchmark dataset for quantitative evaluation and on a real-image dataset consisting of aerial imagery. The experiments reveal that an inverse sampling achieves equal and better results than a linear sampling, with less sampling points and thus less runtime. Our algorithm allows an online computation of depth maps for subsequences of five frames, provided that the relative

  3. DETERMINING PLANE-SWEEP SAMPLING POINTS IN IMAGE SPACE USING THE CROSS-RATIO FOR IMAGE-BASED DEPTH ESTIMATION

    Directory of Open Access Journals (Sweden)

    B. Ruf

    2017-08-01

    Full Text Available With the emergence of small consumer Unmanned Aerial Vehicles (UAVs, the importance and interest of image-based depth estimation and model generation from aerial images has greatly increased in the photogrammetric society. In our work, we focus on algorithms that allow an online image-based dense depth estimation from video sequences, which enables the direct and live structural analysis of the depicted scene. Therefore, we use a multi-view plane-sweep algorithm with a semi-global matching (SGM optimization which is parallelized for general purpose computation on a GPU (GPGPU, reaching sufficient performance to keep up with the key-frames of input sequences. One important aspect to reach good performance is the way to sample the scene space, creating plane hypotheses. A small step size between consecutive planes, which is needed to reconstruct details in the near vicinity of the camera may lead to ambiguities in distant regions, due to the perspective projection of the camera. Furthermore, an equidistant sampling with a small step size produces a large number of plane hypotheses, leading to high computational effort. To overcome these problems, we present a novel methodology to directly determine the sampling points of plane-sweep algorithms in image space. The use of the perspective invariant cross-ratio allows us to derive the location of the sampling planes directly from the image data. With this, we efficiently sample the scene space, achieving higher sampling density in areas which are close to the camera and a lower density in distant regions. We evaluate our approach on a synthetic benchmark dataset for quantitative evaluation and on a real-image dataset consisting of aerial imagery. The experiments reveal that an inverse sampling achieves equal and better results than a linear sampling, with less sampling points and thus less runtime. Our algorithm allows an online computation of depth maps for subsequences of five frames, provided that

  4. PIXE depth profiling using variation of detection angle

    International Nuclear Information System (INIS)

    Miranda, J.; Rickards, J.; Trejo-Luna, R.

    2006-01-01

    A method to apply particle induced X-ray emission (PIXE) for depth profiling, based on the variation of the X-ray detection angle, is proposed. The procedure uses X-ray yields normalized to those emitted at a particular reference angle. Application of the method to implanted samples and thin metallic films gave excellent results regarding the range of implanted ions and film thickness, respectively. However, there is no complete information about the width of the distribution of the implanted ions, emphasizing the need to develop a full mathematical algorithm to obtain the general depth profile

  5. Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range.

    Science.gov (United States)

    Wan, Xiang; Wang, Wenqian; Liu, Jiming; Tong, Tiejun

    2014-12-19

    In systematic reviews and meta-analysis, researchers often pool the results of the sample mean and standard deviation from a set of similar clinical trials. A number of the trials, however, reported the study using the median, the minimum and maximum values, and/or the first and third quartiles. Hence, in order to combine results, one may have to estimate the sample mean and standard deviation for such trials. In this paper, we propose to improve the existing literature in several directions. First, we show that the sample standard deviation estimation in Hozo et al.'s method (BMC Med Res Methodol 5:13, 2005) has some serious limitations and is always less satisfactory in practice. Inspired by this, we propose a new estimation method by incorporating the sample size. Second, we systematically study the sample mean and standard deviation estimation problem under several other interesting settings where the interquartile range is also available for the trials. We demonstrate the performance of the proposed methods through simulation studies for the three frequently encountered scenarios, respectively. For the first two scenarios, our method greatly improves existing methods and provides a nearly unbiased estimate of the true sample standard deviation for normal data and a slightly biased estimate for skewed data. For the third scenario, our method still performs very well for both normal data and skewed data. Furthermore, we compare the estimators of the sample mean and standard deviation under all three scenarios and present some suggestions on which scenario is preferred in real-world applications. In this paper, we discuss different approximation methods in the estimation of the sample mean and standard deviation and propose some new estimation methods to improve the existing literature. We conclude our work with a summary table (an Excel spread sheet including all formulas) that serves as a comprehensive guidance for performing meta-analysis in different

  6. Reconstruction in PET cameras with irregular sampling and depth of interaction capability

    International Nuclear Information System (INIS)

    Virador, P.R.G.; Moses, W.W.; Huesman, R.H.

    1998-01-01

    The authors present 2D reconstruction algorithms for a rectangular PET camera capable of measuring depth of interaction (DOI). The camera geometry leads to irregular radial and angular sampling of the tomographic data. DOI information increases sampling density, allowing the use of evenly spaced quarter-crystal width radial bins with minimal interpolation of irregularly spaced data. In the regions where DOI does not increase sampling density (chords normal to crystal faces), fine radial sinogram binning leads to zero efficiency bins if uniform angular binning is used. These zero efficiency sinogram bins lead to streak artifacts if not corrected. To minimize these unnormalizable sinogram bins the authors use two angular binning schemes: Fixed Width and Natural Width. Fixed Width uses a fixed angular width except in the problem regions where appropriately chosen widths are applied. Natural Width uses angle widths which are derived from intrinsic detector sampling. Using a modified filtered-backprojection algorithm to accommodate these angular binning schemes, the authors reconstruct artifact free images with nearly isotropic and position independent spatial resolution. Results from Monte Carlo data indicate that they have nearly eliminated image degradation due to crystal penetration

  7. NOAA TIFF Image - 4m Bathymetric Depth Range of Red Snapper Research Areas in the South Atlantic Bight, 2010

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains unified Bathymetric Depth Range GeoTiffs with 4x4 meter cell resolution describing the topography of 15 areas along the shelf edge off the...

  8. Improving depth resolutions in positron beam spectroscopy by concurrent ion-beam sputtering

    Science.gov (United States)

    John, Marco; Dalla, Ayham; Ibrahim, Alaa M.; Anwand, Wolfgang; Wagner, Andreas; Böttger, Roman; Krause-Rehberg, Reinhard

    2018-05-01

    The depth resolution of mono-energetic positron annihilation spectroscopy using a positron beam is shown to improve by concurrently removing the sample surface layer during positron beam spectroscopy. During ion-beam sputtering with argon ions, Doppler-broadening spectroscopy is performed with energies ranging from 3 keV to 5 keV allowing for high-resolution defect studies just below the sputtered surface. With this technique, significantly improved depth resolutions could be obtained even at larger depths when compared to standard positron beam experiments which suffer from extended positron implantation profiles at higher positron energies. Our results show that it is possible to investigate layered structures with a thickness of about 4 microns with significantly improved depth resolution. We demonstrated that a purposely generated ion-beam induced defect profile in a silicon sample could be resolved employing the new technique. A depth resolution of less than 100 nm could be reached.

  9. Impact of sampling depth and plant species on local environmental conditions, microbiological parameters and bacterial composition in a mercury contaminated salt marsh

    International Nuclear Information System (INIS)

    Cleary, D.F.R.; Oliveira, V.; Gomes, N.C.M.; Pereira, A.; Henriques, I.; Marques, B.; Almeida, A.; Cunha, A.; Correia, A.; Lillebø, A.I.

    2012-01-01

    Highlights: ► Vegetated habitat contained distinct bacterial communities. ► Variation in bacterial composition with depth differed between plant species. ► There is evidence of an effect of mercury concentration on bacterial composition. ► Depth and sampling depth explained almost 70% of the variation in bacterial composition. - Abstract: We compare the environmental characteristics and bacterial communities associated with two rushes, Juncus maritimus and Bolboschoenus maritimus, and adjacent unvegetated habitat in a salt marsh subjected to historical mercury pollution. Mercury content was higher in vegetated than unvegetated habitat and increased with sampling depth. There was also a significant relationship between mercury concentration and bacterial composition. Habitat (Juncus, Bolboschoenus or unvegetated), sample depth, and the interaction between both, however, explained most of the variation in composition (∼70%). Variation in composition with depth was most prominent for the unvegetated habitat, followed by Juncus, but more constrained for Bolboschoenus habitat. This constraint may be indicative of a strong plant–microbe ecophysiological adaptation. Vegetated habitat contained distinct bacterial communities associated with higher potential activity of aminopeptidase, β-glucosidase and arylsulphatase and incorporation rates of 14 C-glucose and 14 C-acetate. Communities in unvegetated habitat were, in contrast, associated with both higher pH and proportion of sulphate reducing bacteria.

  10. Wavelength-dependent penetration depth of near infrared radiation into cartilage.

    Science.gov (United States)

    Padalkar, M V; Pleshko, N

    2015-04-07

    Articular cartilage is a hyaline cartilage that lines the subchondral bone in the diarthrodial joints. Near infrared (NIR) spectroscopy is emerging as a nondestructive modality for the evaluation of cartilage pathology; however, studies regarding the depth of penetration of NIR radiation into cartilage are lacking. The average thickness of human cartilage is about 1-3 mm, and it becomes even thinner as OA progresses. To ensure that spectral data collected is restricted to the tissue of interest, i.e. cartilage in this case, and not from the underlying subchondral bone, it is necessary to determine the depth of penetration of NIR radiation in different wavelength (frequency) regions. In the current study, we establish how the depth of penetration varies throughout the NIR frequency range (4000-10 000 cm(-1)). NIR spectra were collected from cartilage samples of different thicknesses (0.5 mm to 5 mm) with and without polystyrene placed underneath. A separate NIR spectrum of polystyrene was collected as a reference. It was found that the depth of penetration varied from ∼1 mm to 2 mm in the 4000-5100 cm(-1) range, ∼3 mm in the 5100-7000 cm(-1) range, and ∼5 mm in the 7000-9000 cm(-1) frequency range. These findings suggest that the best NIR region to evaluate cartilage with no subchondral bone contribution is in the range of 4000-7000 cm(-1).

  11. Assessment of helminth load in faecal samples of free range ...

    African Journals Online (AJOL)

    Helminths load in faecal sample of free range indigenous chicken in Port Harcourt Metropolis was examined. Faecal samples were collected from 224 birds in 15 homesteads and 4 major markets - Mile 3, Mile 1, Borokiri and Eneka Village market where poultry birds are gathered for sale. 0.2-0.5g of feacal sample was ...

  12. Cone penetrometer testing and discrete-depth groundwater sampling techniques: A cost-effective method of site characterization in a multiple-aquifer setting

    International Nuclear Information System (INIS)

    Zemo, D.A.; Pierce, Y.G.; Gallinatti, J.D.

    1992-01-01

    Cone penetrometer testing (CPT), combined with discrete-depth groundwater sampling methods, can reduce significantly the time and expense required to characterize large sites that have multiple aquifers. Results from the screening site characterization can be used to design and install a cost-effective monitoring well network. At a site in northern California, it was necessary to characterize the stratigraphy and the distribution of volatile organic compounds (VOCs) to a depth of 80 feet within a 1/2 mile-by-1/4-mile residential and commercial area in a complex alluvial fan setting. To expedite site characterization, a five-week field screening program was implemented that consisted of a shallow groundwater survey, CPT soundings, and discrete-depth groundwater sampling. Based on continuous lithologic information provided by the CPT soundings, four coarse-grained water-yielding sedimentary packages were identified. Eighty-three discrete-depth groundwater samples were collected using shallow groundwater survey techniques, the BAT Enviroprobe, or the QED HydroPunch 1, depending on subsurface conditions. A 20-well monitoring network was designed and installed to monitor critical points within each sedimentary package. Understanding the vertical VOC distribution and concentrations produced substantial cost savings by minimizing the number of permanent monitoring wells and reducing the number of costly conductor casings to be installed. Significant long-term cost savings will result from reduced sampling costs. Where total VOC concentrations exceeded 20 φg/l in the screening samples, a good correlation was found between the discrete-depth screening data and data from monitoring wells. Using a screening program to characterize the site before installing monitoring wells resulted in an estimated 50-percent reduction in costs for site characterization, 65-percent reduction in time for site characterization, and 50-percent reduction in long-term monitoring costs

  13. Mud Volcanoes in the Martian Lowlands: Potential Windows to Fluid-Rich Samples from Depth

    Science.gov (United States)

    Oehler, Dorothy Z.; Allen, Carlton C.

    2009-01-01

    The regional setting of the Chryse-Acidalia area augurs well for a fluid-rich subsurface, accumulation of diverse rock types reflecting the wide catchment area, astrobiological prospectivity, and mud volcanism. This latter provides a mechanism for transporting samples from relatively great depth to the surface. Since mud volcanoes are not associated with extreme heat or shock pressures, materials they transport to the surface are likely to be relatively unaltered; thus such materials could contain interpretable remnants of potential martian life (e.g., organic chemical biomarkers, mineral biosignatures, or structural remains) as well as unmetamorphosed rock samples. None of the previous landings on Mars was located in an area with features identified as potential mud volcanoes (Fig. 3), but some of these features may offer targets for future missions aimed at sampling deep fluid-rich strata with potential habitable zones.

  14. Derivation of Burn Scar Depths with Airborne Light Detection and Ranging (LIDAR) in Indonesian Peatlands

    Science.gov (United States)

    Ballhorn, U.; Siegert, F.

    2009-04-01

    Tropical deforestation and forest degradation contribute to about 20% of the global greenhouse gas emissions and Indonesia is a leading emitter. Forests are certainly critical; but the peat soils beneath can store 30 times more carbon than the trees above. Indonesia has the fourth-largest area of peatland in the world, ranging from 30 to 45 million ha, which is approximately 10 - 12% of the global peatland resource. Fire has a long tradition in Indonesian land clearing, where almost all fires are related to human activities. The 1997 - 1998 fires throughout Indonesia caused significant haze and smoke-related health problems across Southeast Asia. Strong and weak El Niño events in 1998 and 2002 accelerated burning as soil was parched. Green house gas emissions from the fires were the source of 60% of all anomalies globally for 1997 - 2000, particularly from drained peatlands. In 2007/08 we participated in a study conducted by the World Wildlife Fund which focused on Sumatra's 8.3 million ha province of Riau, along the island's northeastern coastline. In this study CO2 emissions from deforestation and forest degradation, peat decomposition and burning over 17 years from 1990 - 2007 were estimated. Fire hotspot data for the years 1997 - 2000 from the NOAA AVHRR and MODIS sensors was used to identify burned peatland. Based on soil water availability the depths of peat burns were estimated. El Nino years with a water table of lower than 1.5 m propel intense burning so that a peat burn depth of 0.50 m was assumed, while normally only a peat burn depth of 0.15 m. Total emissions for the 1990 - 2007 period were estimated at 3.66 Gt CO2, composed of 1.17 Gt CO2 from deforestation, 0.32 Gt CO2 from forest degradation, 0.78 Gt CO2 from peat decomposition, and 1.39 Gt CO2 from peat burning. Average annual CO2 emissions were 0.22 Gt, equal to 58% of Australia's total CO2 annual emissions (including emissions/removals from LULUCF, in 2005); between 1990 and 2007, Riau produced

  15. Mechanism of long-range penetration of low-energy ions in botanic samples

    International Nuclear Information System (INIS)

    Liu Feng; Wang Yugang; Xue Jianming; Wang Sixue; Du Guanghua; Yan Sha; Zhao Weijiang

    2002-01-01

    The authors present experimental evidence to reveal the mechanism of long-range penetration of low-energy ions in botanic samples. In the 100 keV Ar + ion transmission measurement, the result confirmed that low-energy ions could penetrate at least 60 μm thick kidney bean slices with the probability of about 1.0 x 10 -5 . The energy spectrum of 1 MeV He + ions penetrating botanic samples has shown that there is a peak of the count of ions with little energy loss. The probability of the low-energy ions penetrating the botanic sample is almost the same as that of the high-energy ions penetrating the same samples with little energy loss. The results indicate that there are some micro-regions with mass thickness less than the projectile range of low-energy ions in the botanic samples and they result in the long-range penetration of low-energy ions in botanic samples

  16. Effects of sample size and sampling frequency on studies of brown bear home ranges and habitat use

    Science.gov (United States)

    Arthur, Steve M.; Schwartz, Charles C.

    1999-01-01

    We equipped 9 brown bears (Ursus arctos) on the Kenai Peninsula, Alaska, with collars containing both conventional very-high-frequency (VHF) transmitters and global positioning system (GPS) receivers programmed to determine an animal's position at 5.75-hr intervals. We calculated minimum convex polygon (MCP) and fixed and adaptive kernel home ranges for randomly-selected subsets of the GPS data to examine the effects of sample size on accuracy and precision of home range estimates. We also compared results obtained by weekly aerial radiotracking versus more frequent GPS locations to test for biases in conventional radiotracking data. Home ranges based on the MCP were 20-606 km2 (x = 201) for aerial radiotracking data (n = 12-16 locations/bear) and 116-1,505 km2 (x = 522) for the complete GPS data sets (n = 245-466 locations/bear). Fixed kernel home ranges were 34-955 km2 (x = 224) for radiotracking data and 16-130 km2 (x = 60) for the GPS data. Differences between means for radiotracking and GPS data were due primarily to the larger samples provided by the GPS data. Means did not differ between radiotracking data and equivalent-sized subsets of GPS data (P > 0.10). For the MCP, home range area increased and variability decreased asymptotically with number of locations. For the kernel models, both area and variability decreased with increasing sample size. Simulations suggested that the MCP and kernel models required >60 and >80 locations, respectively, for estimates to be both accurate (change in area bears. Our results suggest that the usefulness of conventional radiotracking data may be limited by potential biases and variability due to small samples. Investigators that use home range estimates in statistical tests should consider the effects of variability of those estimates. Use of GPS-equipped collars can facilitate obtaining larger samples of unbiased data and improve accuracy and precision of home range estimates.

  17. The novel programmable riometer for in-depth ionospheric and magnetospheric observations (PRIAMOS) using direct sampling DSP techniques

    OpenAIRE

    Dekoulis, G.; Honary, F.

    2005-01-01

    This paper describes the feasibility study and simulation results for the unique multi-frequency, multi-bandwidth, Programmable Riometer for in-depth Ionospheric And Magnetospheric ObservationS (PRIAMOS) based on direct sampling digital signal processing (DSP) techniques. This novel architecture is based on sampling the cosmic noise wavefront at the antenna. It eliminates the usage of any intermediate frequency (IF) mixer stages (-6 dB) and the noise balancing technique (-3 dB), providing a m...

  18. Self-interference fluorescence microscopy with three-phase detection for depth-resolved confocal epi-fluorescence imaging.

    Science.gov (United States)

    Braaf, Boy; de Boer, Johannes F

    2017-03-20

    Three-dimensional confocal fluorescence imaging of in vivo tissues is challenging due to sample motion and limited imaging speeds. In this paper a novel method is therefore presented for scanning confocal epi-fluorescence microscopy with instantaneous depth-sensing based on self-interference fluorescence microscopy (SIFM). A tabletop epi-fluorescence SIFM setup was constructed with an annular phase plate in the emission path to create a spectral self-interference signal that is phase-dependent on the axial position of a fluorescent sample. A Mach-Zehnder interferometer based on a 3 × 3 fiber-coupler was developed for a sensitive phase analysis of the SIFM signal with three photon-counter detectors instead of a spectrometer. The Mach-Zehnder interferometer created three intensity signals that alternately oscillated as a function of the SIFM spectral phase and therefore encoded directly for the axial sample position. Controlled axial translation of fluorescent microsphere layers showed a linear dependence of the SIFM spectral phase with sample depth over axial image ranges of 500 µm and 80 µm (3.9 × Rayleigh range) for 4 × and 10 × microscope objectives respectively. In addition, SIFM was in good agreement with optical coherence tomography depth measurements on a sample with indocyanine green dye filled capillaries placed at multiple depths. High-resolution SIFM imaging applications are demonstrated for fluorescence angiography on a dye-filled capillary blood vessel phantom and for autofluorescence imaging on an ex vivo fly eye.

  19. Three-dimensional range data compression using computer graphics rendering pipeline.

    Science.gov (United States)

    Zhang, Song

    2012-06-20

    This paper presents the idea of naturally encoding three-dimensional (3D) range data into regular two-dimensional (2D) images utilizing computer graphics rendering pipeline. The computer graphics pipeline provides a means to sample 3D geometry data into regular 2D images, and also to retrieve the depth information for each sampled pixel. The depth information for each pixel is further encoded into red, green, and blue color channels of regular 2D images. The 2D images can further be compressed with existing 2D image compression techniques. By this novel means, 3D geometry data obtained by 3D range scanners can be instantaneously compressed into 2D images, providing a novel way of storing 3D range data into its 2D counterparts. We will present experimental results to verify the performance of this proposed technique.

  20. The Beryllium 7 Depth Distribution Study

    International Nuclear Information System (INIS)

    Jalal Sharib; Zainudin Othman; Dainee Nor Fardzila Ahmad Tugi

    2014-01-01

    The aim of this paper is to study the evolution of 7Be depth distribution in a soil profile. The soil samples have been collected by using plastic core in bare area in Bangi, Malaysia. Each of the soil core samples has been sectioned into 2 mm increments to a depth of 4 cm and the samples are subsequently oven dried at 45°C and gently disaggregated. The sample is passed through a < 2 mm sieve and packed into plastic pot for 7Be analysis using gamma spectrometry with a 24 hour count time. From the findings, show the 7Be depth penetration from this study decreases exponentially with depth and is confined within the top few centimeters and similar with other works been reported. The further discussion for this findings will be presented in full paper. (author)

  1. Long range surface plasmon resonance with ultra-high penetration depth for self-referenced sensing and ultra-low detection limit using diverging beam approach

    Energy Technology Data Exchange (ETDEWEB)

    Isaacs, Sivan, E-mail: sivan.isaacs@gmail.com; Abdulhalim, Ibrahim [Department of Electro-Optical Engineering and TheIlse Katz Institute for Nanoscale Science and Technology, Ben Gurion University of the Negev, Beer Sheva 84105 (Israel); NEW CREATE Programme, School of Materials Science and Engineering, 1 CREATE Way, Research Wing, #02-06/08, Singapore 138602 (Singapore)

    2015-05-11

    Using an insulator-metal-insulator structure with dielectric having refractive index (RI) larger than the analyte, long range surface plasmon (SP) resonance exhibiting ultra-high penetration depth is demonstrated for sensing applications of large bioentities at wavelengths in the visible range. Based on the diverging beam approach in Kretschmann-Raether configuration, one of the SP resonances is shown to shift in response to changes in the analyte RI while the other is fixed; thus, it can be used as a built in reference. The combination of the high sensitivity, high penetration depth and self-reference using the diverging beam approach in which a dark line is detected of the high sensitivity, high penetration depth, self-reference, and the diverging beam approach in which a dark line is detected using large number of camera pixels with a smart algorithm for sub-pixel resolution, a sensor with ultra-low detection limit is demonstrated suitable for large bioentities.

  2. Characterization of the March 2017 tank 10 surface sample (combination of HTF-10-17-30 AND HTF-10-17-31) and variable depth sample (combination of HTF-10-17-32 and HTF-10-17-33)

    Energy Technology Data Exchange (ETDEWEB)

    Reboul, S. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-07-19

    Two surface samples (HTF-10-17-30 and HTF-10-17-31) and two variable depth samples (HTF-10-17-32 and HTF-10-17-33) were collected from SRS Tank 10 during March 2017 and submitted to SRNL for characterization. At SRNL, the two surface samples were combined in one container, the two variable depth samples (VDSs) were combined in another container, and then the two composite samples were each characterized by a series of physical, ionic, radiological, and elemental analysis methods. The surface sample composite was characterized primarily for Tank Farm corrosion control purposes, while the VDS composite was characterized primarily for Tank Closure Cesium Removal (TCCR) purposes.

  3. Simplicial band depth for multivariate functional data

    KAUST Repository

    López-Pintado, Sara

    2014-03-05

    We propose notions of simplicial band depth for multivariate functional data that extend the univariate functional band depth. The proposed simplicial band depths provide simple and natural criteria to measure the centrality of a trajectory within a sample of curves. Based on these depths, a sample of multivariate curves can be ordered from the center outward and order statistics can be defined. Properties of the proposed depths, such as invariance and consistency, can be established. A simulation study shows the robustness of this new definition of depth and the advantages of using a multivariate depth versus the marginal depths for detecting outliers. Real data examples from growth curves and signature data are used to illustrate the performance and usefulness of the proposed depths. © 2014 Springer-Verlag Berlin Heidelberg.

  4. Visual Discomfort and Depth-of-Field

    Directory of Open Access Journals (Sweden)

    Louise O'Hare

    2013-05-01

    Full Text Available Visual discomfort has been reported for certain visual stimuli and under particular viewing conditions, such as stereoscopic viewing. In stereoscopic viewing, visual discomfort can be caused by a conflict between accommodation and convergence cues that may specify different distances in depth. Earlier research has shown that depth-of-field, which is the distance range in depth in the scene that is perceived to be sharp, influences both the perception of egocentric distance to the focal plane, and the distance range in depth between objects in the scene. Because depth-of-field may also be in conflict with convergence and the accommodative state of the eyes, we raised the question of whether depth-of-field affects discomfort when viewing stereoscopic photographs. The first experiment assessed whether discomfort increases when depth-of-field is in conflict with coherent accommodation–convergence cues to distance in depth. The second experiment assessed whether depth-of-field influences discomfort from a pre-existing accommodation–convergence conflict. Results showed no effect of depth-of-field on visual discomfort. These results suggest therefore that depth-of-field can be used as a cue to depth without inducing discomfort in the viewer, even when cue conflicts are large.

  5. Influence of depth on sex-specific energy allocation patterns in a tropical reef fish

    Science.gov (United States)

    Hoey, J.; McCormick, M. I.; Hoey, A. S.

    2007-09-01

    The effect of depth on the distribution and sex-specific energy allocation patterns of a common coral reef fish, Chrysiptera rollandi (Pomacentridae), was investigated using depth-stratified collections over a broad depth range (5-39 m) and a translocation experiment. C. rollandi consistently selected rubble habitats at each depth, however abundance patterns did not reflect the availability of the preferred microhabitat suggesting a preference for depth as well as microhabitat. Reproductive investment (gonado-somatic index), energy stores (liver cell density and hepatocyte vacuolation), and overall body condition (hepato-somatic index and Fulton’s K) of female fish varied significantly among depths and among the three reefs sampled. Male conspecifics displayed no variation between depth or reef. Depth influenced growth dynamics, with faster initial growth rates and smaller mean asymptotic lengths with decreasing depth. In female fish, relative gonad weight and overall body condition (Fulton’s K and hepato-somatic index) were generally higher in shallower depths (≤10 m). Hepatic lipid storage was highest at the deepest sites sampled on each reef, whereas hepatic glycogen stores tended to decrease with depth. Depth was found to influence energy allocation dynamics in C. rollandi. While it is unclear what processes directly influenced the depth-related patterns in energy allocation, this study shows that individuals across a broad depth gradient are not all in the same physiological state and may contribute differentially to the population reproductive output.

  6. ACCURACY ANALYSIS OF KINECT DEPTH DATA

    Directory of Open Access Journals (Sweden)

    K. Khoshelham

    2012-09-01

    Full Text Available This paper presents an investigation of the geometric quality of depth data obtained by the Kinect sensor. Based on the mathematical model of depth measurement by the sensor a theoretical error analysis is presented, which provides an insight into the factors influencing the accuracy of the data. Experimental results show that the random error of depth measurement increases with increasing distance to the sensor, and ranges from a few millimetres up to about 4 cm at the maximum range of the sensor. The accuracy of the data is also found to be influenced by the low resolution of the depth measurements.

  7. Engineering task plan for development, fabrication, and deployment of nested, fixed depth fluidic sampling and at-tank analysis systems

    International Nuclear Information System (INIS)

    REICH, F.R.

    1999-01-01

    An engineering task plan was developed that presents the resources, responsibilities, and schedules for the development, test, and deployment of the nested, fixed-depth fluidic sampling and at-tank analysis system. The sampling system, deployed in the privatization contract double-shell tank feed tank, will provide waste samples for assuring the readiness of the tank for shipment to the privatization contractor for vitrification. The at-tank analysis system will provide ''real-time'' assessments of the sampled wastes' chemical and physical properties. These systems support the Hanford Phase 1B Privatization Contract

  8. Factors controlling contrail cirrus optical depth

    Directory of Open Access Journals (Sweden)

    B. Kärcher

    2009-08-01

    Full Text Available Aircraft contrails develop into contrail cirrus by depositional growth and sedimentation of ice particles and horizontal spreading due to wind shear. Factors controlling this development include temperature, ice supersaturation, thickness of ice-supersaturated layers, and vertical gradients in the horizontal wind field. An analytical microphysical cloud model is presented and validated that captures these processes. Many individual contrail cirrus are simulated that develop differently owing to the variability in the controlling factors, resulting in large samples of cloud properties that are statistically analyzed. Contrail cirrus development is studied over the first four hours past formation, similar to the ages of line-shaped contrails that were tracked in satellite imagery on regional scales. On these time scales, contrail cirrus optical depth and microphysical variables exhibit a marked variability, expressed in terms of broad and skewed probability distribution functions. Simulated mean optical depths at a wavelength of 0.55 μm range from 0.05-0.5 and a substantial fraction 20-50% of contrail cirrus stay subvisible (optical depth <0.02, depending on meteorological conditions.

    A detailed analysis based on an observational case study over the continental USA suggests that previous satellite measurements of line-shaped persistent contrails have missed about 89%, 50%, and 11% of contrails with optical depths 0-0.05, 0.05-0.1, and 0.1-0.2, respectively, amounting to 65% of contrail coverage of all optical depths. When comparing observations with simulations and when estimating the contrail cirrus climate impact, not only mean values but also the variability in optical depth and microphysical properties need to be considered.

  9. Simplicial band depth for multivariate functional data

    KAUST Repository

    Ló pez-Pintado, Sara; Sun, Ying; Lin, Juan K.; Genton, Marc G.

    2014-01-01

    sample of curves. Based on these depths, a sample of multivariate curves can be ordered from the center outward and order statistics can be defined. Properties of the proposed depths, such as invariance and consistency, can be established. A simulation

  10. Effect of gamma irradiation on storability and chemical properties of different depth samples of luncheon

    International Nuclear Information System (INIS)

    Al-Bachir, M.; Farah, S.

    2000-03-01

    To investigate the effect of gamma irradiation on shelf-life of luncheon, meat packs were exposed to doses of 0, 1, 2 and 3 kGy in a 60 Co package irradiator, and the irradiated and unirradiated samples were stored at refrigeration temperature (1-3 centigrade). Microbial population and chemical changes were evaluated through storage periods (2, 4, 6 weeks) on the surface and depth in the of meat packs. The results indicated that gamma irradiation reduced the counts of microorganisms inside the samples more than the surfaces. Also the shelf-life of luncheon meat increased from two weeks for the control to 5 weeks for irradiated samples (2 and 3 kGy). Total acidity, lipid oxidation and the volatile basic nitrogen (VBN) increased during the first stage of storage up to 2 weeks of irradiation, furthermore these values were significantly higher (P> 0.05) on the surface than inside the meat packs. (author)

  11. Element depth profiles of porous silicon

    International Nuclear Information System (INIS)

    Kobzev, A.P.; Nikonov, O.A.; Kulik, M.; Zuk, J.; Krzyzanowska, H.; Ochalski, T.J.

    1997-01-01

    Element depth profiles of porous silicon were measured on the Van-de-Graaff accelerator in the energy range of 4 He + ions from 2 to 3.2 MeV. Application of complementary RBS, ERD and 16 O(α,α) 16 O nuclear reaction methods permits us to obtain: 1) the exact silicon, oxygen and hydrogen distribution in the samples, 2) the distribution of partial pore concentrations. The oxygen concentration in porous silicon reaches 30%, which allows one to assume the presence of silicon oxide in the pores and to explain the spectrum shift of luminescence into the blue area

  12. Study of the disorder by means of the superconducting penetration depth

    International Nuclear Information System (INIS)

    Arce, R.D.

    1982-11-01

    Measurements of the weak magnetic field penetration depth in the amorphous superconducting systems Lasub(1-x) Msub(x), being M = Cu, Al, Ga and Au, and in the Zr 70 Cu 30 system are presented. Measurements of the sample geometrical factors and the flux expulsion between the lowest temperature reached and the critical temperature, allows the determination of zero temperature penetration depth. The measurement of the flux expulsion as a function of temperature is used to determine the temperature dependence of penetration depth, used to evaluate the temperature dependence superconducting gap. The magnetization measurements have been made using an rf-SQUID. The evolution of the penetration depth with annealing is studied in the La 70 Cu 30 and Zr 70 Cu 30 systems. Measurements of the electrical resistivity and the critical temperature are used to verify the Gorkov equations in these materials. The variation of the penetration depth with annealing suggests that a metallurgical phase separation occurs within the submicrometer range. Penetration depth measurement is a tool to detect this type of phase separation in high kappa materials. (M.E.L.) [es

  13. Application of Multivariate Empirical Mode Decomposition and Sample Entropy in EEG Signals via Artificial Neural Networks for Interpreting Depth of Anesthesia

    Directory of Open Access Journals (Sweden)

    Jiann-Shing Shieh

    2013-08-01

    Full Text Available EEG (Electroencephalography signals can express the human awareness activities and consequently it can indicate the depth of anesthesia. On the other hand, Bispectral-index (BIS is often used as an indicator to assess the depth of anesthesia. This study is aimed at using an advanced signal processing method to analyze EEG signals and compare them with existing BIS indexes from a commercial product (i.e., IntelliVue MP60 BIS module. Multivariate empirical mode decomposition (MEMD algorithm is utilized to filter the EEG signals. A combination of two MEMD components (IMF2 + IMF3 is used to express the raw EEG. Then, sample entropy algorithm is used to calculate the complexity of the patients’ EEG signal. Furthermore, linear regression and artificial neural network (ANN methods were used to model the sample entropy using BIS index as the gold standard. ANN can produce better target value than linear regression. The correlation coefficient is 0.790 ± 0.069 and MAE is 8.448 ± 1.887. In conclusion, the area under the receiver operating characteristic (ROC curve (AUC of sample entropy value using ANN and MEMD is 0.969 ± 0.028 while the AUC of sample entropy value without filter is 0.733 ± 0.123. It means the MEMD method can filter out noise of the brain waves, so that the sample entropy of EEG can be closely related to the depth of anesthesia. Therefore, the resulting index can be adopted as the reference for the physician, in order to reduce the risk of surgery.

  14. Depth profile and interface analysis in the nm-range

    International Nuclear Information System (INIS)

    Oswald, S.; Reiche, R.; Zier, M.; Baunack, S.; Wetzig, K.

    2005-01-01

    In modern technology, thin films are shrinking more and more to a thickness of few nanometers. Analytical investigations of such thin films using the traditional sputter depth profiling, sputtering in combination with surface-analytical techniques, have limitations due to physical effects especially for very thin films. These limitations are pointed out and some alternatives are discussed. Non-destructive analysis with angle-resolved X-ray photoelectron spectroscopy is demonstrated to be a useful method for such investigations. Both qualitative and quantitative results can be obtained even for complex layer structures. Nevertheless, there are also limitations of this method and some alternatives or complementary methods are considered

  15. Overview of SAFOD Phases 1 and 2: Drilling, Sampling and Measurements in the San Andreas Fault Zone at Seismogenic Depth

    Science.gov (United States)

    Zoback, M. D.; Hickman, S.; Ellsworth, W.

    2005-12-01

    In this talk we provide an overview of on-site drilling, sampling and downhole measurement activities associated with the first two Phases of the San Andreas Fault Observatory at Depth. SAFOD is located at the transition between the creeping and locked sections of the fault, 9 km NW of Parkfield, CA. A 2.1 km deep vertical pilot hole was drilled at the site in 2002. The SAFOD main borehole was drilled vertically to a depth of 1.5 km and then deviated at an average angle of 55° to vertical, passing beneath the surface trace of the San Andreas fault, 1.8 km to the NW at a depth of 3.2 km. Repeating microearthquakes on the San Andreas define the main active fault trace at depth, as well as a secondary active fault about 250 m to the SW (i.e., closer to SAFOD). The hole was rotary drilled, comprehensive cuttings were obtained and a real-time analysis of gases in the drilling mud was carried out. Spot cores were obtained at three depths (at casing set points) in the shallow granite and deeper sedimentary rocks penetrated by the hole, augmented by over fifty side-wall cores. Continuous coring of the San Andreas Fault Zone will be carried out in Phase 3 of the project in the summer of 2007. In addition to sampling mud gas, discrete fluid and gas samples were obtained at several depths for geochemical analysis. Real-time geophysical measurements were made while drilling through most of the San Andreas Fault Zone. A suite of "open hole" geophysical measurements were also made over essentially the entire depth of the hole. Construction of the multi-component SAFOD observatory is well underway, with a seismometer and tiltmeter operating at 1 km depth in the pilot hole and a fiber-optic laser strainmeter cemented behind casing in the main hole. A seismometer deployed at depth in the hole between Phases 1 and 2 detected one of the target earthquakes. A number of surface-to-borehole seismic experiments have been carried out to characterize seismic velocities and structures at

  16. Effective sampling range of a synthetic protein-based attractant for Ceratitis capitata (Diptera: Tephritidae).

    Science.gov (United States)

    Epsky, Nancy D; Espinoza, Hernán R; Kendra, Paul E; Abernathy, Robert; Midgarden, David; Heath, Robert R

    2010-10-01

    Studies were conducted in Honduras to determine effective sampling range of a female-targeted protein-based synthetic attractant for the Mediterranean fruit fly, Ceratitis capitata (Wiedemann) (Diptera: Tephritidae). Multilure traps were baited with ammonium acetate, putrescine, and trimethylamine lures (three-component attractant) and sampled over eight consecutive weeks. Field design consisted of 38 traps (over 0.5 ha) placed in a combination of standard and high-density grids to facilitate geostatistical analysis, and tests were conducted in coffee (Coffea arabica L.),mango (Mangifera indica L.),and orthanique (Citrus sinensis X Citrus reticulata). Effective sampling range, as determined from the range parameter obtained from experimental variograms that fit a spherical model, was approximately 30 m for flies captured in tests in coffee or mango and approximately 40 m for flies captured in orthanique. For comparison, a release-recapture study was conducted in mango using wild (field-collected) mixed sex C. capitata and an array of 20 baited traps spaced 10-50 m from the release point. Contour analysis was used to document spatial distribution of fly recaptures and to estimate effective sampling range, defined by the area that encompassed 90% of the recaptures. With this approach, effective range of the three-component attractant was estimated to be approximately 28 m, similar to results obtained from variogram analysis. Contour maps indicated that wind direction had a strong influence on sampling range, which was approximately 15 m greater upwind compared with downwind from the release point. Geostatistical analysis of field-captured insects in appropriately designed trapping grids may provide a supplement or alternative to release-recapture studies to estimate sampling ranges for semiochemical-based trapping systems.

  17. Fault rocks from the SAFOD core samples : implications for weakening at shallow depths along the San Andreas Fault, California

    NARCIS (Netherlands)

    Holdsworth, R.E.; van Diggelen, E.W.E.; Spiers, C.J.; Bresser, J.H.P. de; Walker, R.J.; Bown, L.

    2011-01-01

    The drilling of a deep borehole across the actively creeping Parkfield segment of the San Andreas Fault Zone (SAFZ), California, and collection of core materials permit direct geological study of fault zone processes at 2–3 km depth. The three drill cores sample both host and fault rocks and pass

  18. The depth distribution functions of the natural abundances of carbon isotopes in Alfisols thoroughly sampled by thin-layer sampling, and their relation to the dynamics of organic matter in theses soils

    International Nuclear Information System (INIS)

    Becker-Heidmann, P.

    1989-01-01

    The aim of this study was to gain fundamental statements on the relationship between the depth distributions of the natural abundances of 13 C and 14 C isotopes and the dynamics of the organic matter in Alfisols. For this purpose, six Alfisols were investigated: four forest soils from Northern Germany, two of them developed in Loess and two in glacial loam, one West German Loess soil used for fruit-growing and one agricultural granite-gneiss soil from the semiarid part of India. The soil was sampled as succesive horizontal layers of 2 cm depth from an area of 0.5 to 1 m 2 size, starting from the organic down to the C horizon or the lower part of the Bt. This kind of completely thin-layer-wise sampling was applied here for the first time. The carbon content and the natural abundances of the 13 C and the 14 C isotopes of each sample were determined. The δ 13 C value was measured by mass spectrometry. A vacuum preparation line with an electronically controlled cooling unit was constructed thereto. For the determination of the 14 C content, the sample carbon was transferred into benzene, and its activity was measured by liquid scintillation spectrometry. From the combination of the depth distribution functions of the 14 C activity and the δ 13 C value, and with the aid of additional analyses like C/N ratio and particle size distribution, a conclusive interpretation as to the dynamics of the organic matter in the investigated Alfisols is given. (orig./BBR)

  19. A terahertz EO detector with large dynamical range, high modulation depth and signal-noise ratio

    Science.gov (United States)

    Pan, Xinjian; Cai, Yi; Zeng, Xuanke; Zheng, Shuiqin; Li, Jingzhen; Xu, Shixiang

    2017-05-01

    The paper presents a novel design for terahertz (THz) free-space time domain electro-optic (EO) detection where the static birefringent phases of the two balanced arms are set close to zero but opposite to each other. Our theoretical and numerical analyses show this design has much stronger ability to cancel the optical background noise than both THz ellipsometer and traditional crossed polarizer geometry (CPG). Its optical modulation depth is about twice as high as that of traditional CPG, but about ten times as high as that of THz ellipsometer. As for the dynamical range, our improved design is comparable to the THz ellipsometer but obviously larger than the traditional CPG. Some experiments for comparing our improved CPG with traditional CPG agree well with the corresponding theoretical predictions. Our experiments also show that the splitting ratio of the used non-polarization beam splitter is critical for the performance of our design.

  20. Sampling strategies to capture single-cell heterogeneity

    OpenAIRE

    Satwik Rajaram; Louise E. Heinrich; John D. Gordan; Jayant Avva; Kathy M. Bonness; Agnieszka K. Witkiewicz; James S. Malter; Chloe E. Atreya; Robert S. Warren; Lani F. Wu; Steven J. Altschuler

    2017-01-01

    Advances in single-cell technologies have highlighted the prevalence and biological significance of cellular heterogeneity. A critical question is how to design experiments that faithfully capture the true range of heterogeneity from samples of cellular populations. Here, we develop a data-driven approach, illustrated in the context of image data, that estimates the sampling depth required for prospective investigations of single-cell heterogeneity from an existing collection of samples. ...

  1. Precise in situ etch depth control of multilayered III−V semiconductor samples with reflectance anisotropy spectroscopy (RAS equipment

    Directory of Open Access Journals (Sweden)

    Ann-Kathrin Kleinschmidt

    2016-11-01

    Full Text Available Reflectance anisotropy spectroscopy (RAS equipment is applied to monitor dry-etch processes (here specifically reactive ion etching (RIE of monocrystalline multilayered III–V semiconductors in situ. The related accuracy of etch depth control is better than 16 nm. Comparison with results of secondary ion mass spectrometry (SIMS reveals a deviation of only about 4 nm in optimal cases. To illustrate the applicability of the reported method in every day settings for the first time the highly etch depth sensitive lithographic process to form a film lens on the waveguide ridge of a broad area laser (BAL is presented. This example elucidates the benefits of the method in semiconductor device fabrication and also suggests how to fulfill design requirements for the sample in order to make RAS control possible.

  2. Authentication of two samples of ancient Chinese coins with component element depth analysis by confocal 3D XRF

    Science.gov (United States)

    Zhou, Peng; Liu, Zhiguo; Lin, Xiaoyan; Liu, Xin; Ye, Lei; Wang, Xingyi; Pan, Kai; Li, Yude

    2018-05-01

    Two samples of ancient Chinese coins were analyzed with a confocal three-dimensional micro-X-ray fluoroscope. The depth distributions of elemental iron (Fe), calcium (Ca) and copper (Cu) were obtained based on this non-destructive measurement method. One coin, named "Chongning Tongbao", was certified as genuine in accordance with the available archaeological data, whereas another coin, named "Zhenglong Yuanbao", was identified as a reproduction.

  3. Effective depth-of-penetration range due to hardness variation for different lots of nominally identical target material

    Directory of Open Access Journals (Sweden)

    Patrick Frueh

    2016-04-01

    A linear regression analysis of penetration vs. hardness shows that a target hardness increase within the given range of 280–330 BHN may result in a reduction of penetration depth of about 5.8 mm at constant velocity. This is equal to a change of −12% at an impact velocity of 1250 m/s. A multiple linear regression analysis included also the influence of yaw angle and impact velocity. It shows that small yaw angles and slight variations of impact velocities provide a smaller variation of the semi-infinite penetration depths than a variation of target hardness within a typical specification span of 50 BHN. For such a span a change in penetration of approximately −4.8 mm due to hardness variation is found, whereas 1° of yaw angle or −10 m/s of velocity variation gives a change of about −1.0 mm respectively −0.9 mm. For the given example, the overwhelming part of the variation is to be attributed to hardness effects – 4.8 mm out of 5.8 mm (83%. For nominally identical target material the target hardness thus influences the ballistic test results more severely than the typical scatter in impact conditions.

  4. Determining concentration depth profiles in fluorinated networks by means of electric force microscopy

    International Nuclear Information System (INIS)

    Miccio, Luis A.; Kummali, Mohammed M.; Alegria, Angel; Montemartini, Pablo E.; Oyanguren, Patricia A.; Schwartz, Gustavo A.; Colmenero, Juan

    2011-01-01

    By means of electric force microscopy, composition depth profiles were measured with nanometric resolution for a series of fluorinated networks. By mapping the dielectric permittivity along a line going from the surface to the bulk, we were able to experimentally access to the fluorine concentration profile. Obtained data show composition gradient lengths ranging from 30 nm to 80 nm in the near surface area for samples containing from 0.5 to 5 wt. % F, respectively. In contrast, no gradients of concentration were detected in bulk. This method has several advantages over other techniques because it allows profiling directly on a sectional cut of the sample. By combining the obtained results with x-ray photoelectron spectroscopy measurements, we were also able to quantify F/C ratio as a function of depth with nanoscale resolution.

  5. Airborne Surveys of Snow Depth over Arctic Sea Ice

    Science.gov (United States)

    Kwok, R.; Panzer, B.; Leuschen, C.; Pang, S.; Markus, T.; Holt, B.; Gogineni, S.

    2011-01-01

    During the spring of 2009, an ultrawideband microwave radar was deployed as part of Operation IceBridge to provide the first cross-basin surveys of snow thickness over Arctic sea ice. In this paper, we analyze data from three approx 2000 km transects to examine detection issues, the limitations of the current instrument, and the regional variability of the retrieved snow depth. Snow depth is the vertical distance between the air \\snow and snow-ice interfaces detected in the radar echograms. Under ideal conditions, the per echogram uncertainty in snow depth retrieval is approx 4 - 5 cm. The finite range resolution of the radar (approx 5 cm) and the relative amplitude of backscatter from the two interfaces limit the direct retrieval of snow depths much below approx 8 cm. Well-defined interfaces are observed over only relatively smooth surfaces within the radar footprint of approx 6.5 m. Sampling is thus restricted to undeformed, level ice. In early April, mean snow depths are 28.5 +/- 16.6 cm and 41.0 +/- 22.2 cm over first-year and multiyear sea ice (MYI), respectively. Regionally, snow thickness is thinner and quite uniform over the large expanse of seasonal ice in the Beaufort Sea, and gets progressively thicker toward the MYI cover north of Ellesmere Island, Greenland, and the Fram Strait. Snow depth over MYI is comparable to that reported in the climatology by Warren et al. Ongoing improvements to the radar system and the utility of these snow depth measurements are discussed.

  6. High-resolution AUV mapping and sampling of a deep hydrocarbon plume in the Gulf of Mexico

    Science.gov (United States)

    Ryan, J. P.; Zhang, Y.; Thomas, H.; Rienecker, E.; Nelson, R.; Cummings, S.

    2010-12-01

    During NOAA cruise GU-10-02 on the Ship Gordon Gunter, the Monterey Bay Aquarium Research Institute (MBARI) autonomous underwater vehicle (AUV) Dorado was deployed to map and sample a deep (900-1200 m) volume centered approximately seven nautical miles southwest of the Deepwater Horizon wellhead. Dorado was equipped to detect optical and chemical signals of hydrocarbons and to acquire targeted samples. The primary sensor reading used for hydrocarbon detection was colored dissolved organic matter (CDOM) fluorescence (CF). On June 2 and 3, ship cast and subsequent AUV surveys detected elevated CF in a layer between 1100 and 1200 m depth. While the deep volume was mapped in a series of parallel vertical sections, the AUV ran a peak-capture algorithm to target sample acquisition at layer signal peaks. Samples returned by ship CTD/CF rosette sampling and by AUV were preliminarily examined at sea, and they exhibited odor and fluorometric signal consistent with oil. More definitive and detailed results on these samples are forthcoming from shore-based laboratory analyses. During post-cruise analysis, all of the CF data were analyzed to objectively define and map the deep plume feature. Specifically, the maximum expected background CF over the depth range 1000-1200 m was extrapolated from a linear relationship between depth and maximum CF over the depth range 200 to 1000 m. Values exceeding the maximum expected background in the depth range 1000-1200 m were interpreted as signal from a hydrocarbon-enriched plume. Using this definition we examine relationships between CF and other AUV measurements within the plume, illustrate the three-dimensional structure of the plume boundary region that was mapped, describe small-scale layering on isopycnals, and examine short-term variations in plume depth, intensity and hydrographic relationships. Three-dimensional representation of part of a deep hydrocarbon plume mapped and sampled by AUV on June 2-3, 2010.

  7. Proteomic workflow for analysis of archival formalin-fixed and paraffin-embedded clinical samples to a depth of 10 000 proteins.

    Science.gov (United States)

    Wiśniewski, Jacek R; Duś, Kamila; Mann, Matthias

    2013-04-01

    Archival formalin-fixed and paraffin-embedded clinical samples represent a very diverse source of material for proteomic investigation of diseases, often with follow-up patient information. Here, we describe an analytical workflow for analysis of laser-capture microdissected formalin-fixed and paraffin-embedded samples that allows studying proteomes to a depth of 10 000 proteins per sample. The workflow involves lysis of tissue in SDS-containing buffer, detergent removal, and consecutive digestion of the proteins with two enzymes by the multienzyme digestion filter-aided sample preparation method. Resulting peptides are fractionated by pipette-tip based strong anion exchange into six fractions and analyzed by LC-MS/MS on a bench top quadrupole Orbitrap mass spectrometer. Analysis of the data using the MaxQuant software resulted in the identification of 9502 ± 28 protein groups per a 110 nL sample of microdissected cells from human colonic adenoma. This depth of proteome analysis enables systemic insights into the organization of the adenoma cells and an estimation of the abundances of known biomarkers. It also allows the identification of proteins expressed from tumor suppressors, oncogenes, and other key players in the development and progression of the colorectal cancer. Our proteomic platform can be used for quantitative comparisons between samples representing different stages of diseases and thus can be applied to the discovery of biomarkers or drug targets. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Molecular depth profiling of organic and biological materials

    Energy Technology Data Exchange (ETDEWEB)

    Fletcher, John S. [Surface Analysis Research Centre, School of Chemical Engineering and Analytical Science, University of Manchester, Manchester M60 1QD (United Kingdom)]. E-mail: John.Fletcher@manchester.ac.uk; Conlan, Xavier A. [Surface Analysis Research Centre, School of Chemical Engineering and Analytical Science, University of Manchester, Manchester M60 1QD (United Kingdom); Lockyer, Nicholas P. [Surface Analysis Research Centre, School of Chemical Engineering and Analytical Science, University of Manchester, Manchester M60 1QD (United Kingdom); Vickerman, John C. [Surface Analysis Research Centre, School of Chemical Engineering and Analytical Science, University of Manchester, Manchester M60 1QD (United Kingdom)

    2006-07-30

    Atomic depth profiling using secondary ion mass spectrometry, SIMS, is common in the field micro-electronics; however, the generation of molecular information as a function of sample depth is difficult due to the accumulation of damage both on and beneath the sample surface. The introduction of polyatomic ion beams such as SF{sub 5} and C{sub 60} have raised the possibility of overcoming this problem as they deposit the majority of their energy in the upper surface of the sample resulting in increased sputter yields but with a complimentary reduction in sub-surface damage accumulation. In this paper we report the depth profile analysis of the bio-polymer polycaprolactone, PCL, using the polyatomic ions Au{sub 3}{sup +} and C{sub 60}{sup +} and the monoatomic Au{sup +}. Results are compared to recent analysis of a similar sample using SF{sub 5}{sup +}. C{sub 60}{sup +} depth profiling of cellulose is also demonstrated, an experiment that has been reported as unsuccessful when attempted with SF{sub 5}{sup +} implications for biological analysis are discussed.

  9. Improving snow density estimation for mapping SWE with Lidar snow depth: assessment of uncertainty in modeled density and field sampling strategies in NASA SnowEx

    Science.gov (United States)

    Raleigh, M. S.; Smyth, E.; Small, E. E.

    2017-12-01

    The spatial distribution of snow water equivalent (SWE) is not sufficiently monitored with either remotely sensed or ground-based observations for water resources management. Recent applications of airborne Lidar have yielded basin-wide mapping of SWE when combined with a snow density model. However, in the absence of snow density observations, the uncertainty in these SWE maps is dominated by uncertainty in modeled snow density rather than in Lidar measurement of snow depth. Available observations tend to have a bias in physiographic regime (e.g., flat open areas) and are often insufficient in number to support testing of models across a range of conditions. Thus, there is a need for targeted sampling strategies and controlled model experiments to understand where and why different snow density models diverge. This will enable identification of robust model structures that represent dominant processes controlling snow densification, in support of basin-scale estimation of SWE with remotely-sensed snow depth datasets. The NASA SnowEx mission is a unique opportunity to evaluate sampling strategies of snow density and to quantify and reduce uncertainty in modeled snow density. In this presentation, we present initial field data analyses and modeling results over the Colorado SnowEx domain in the 2016-2017 winter campaign. We detail a framework for spatially mapping the uncertainty in snowpack density, as represented across multiple models. Leveraging the modular SUMMA model, we construct a series of physically-based models to assess systematically the importance of specific process representations to snow density estimates. We will show how models and snow pit observations characterize snow density variations with forest cover in the SnowEx domains. Finally, we will use the spatial maps of density uncertainty to evaluate the selected locations of snow pits, thereby assessing the adequacy of the sampling strategy for targeting uncertainty in modeled snow density.

  10. INTERACTION OF IMPULSE ELECTROMAGNETIC FIELDS WITH SURFACES OF METAL SAMPLES

    Directory of Open Access Journals (Sweden)

    V. V. Pavliouchenko

    2006-01-01

    Full Text Available Measurements of maximum tangential component of magnetic intensity Hτm have been carried out in the paper. The measurements have been taken on the surface of metal samples according to time of single current pulse rise in the form of semi-sinusoid of a linear current wire. Measurements have been made with the purpose to determine a value of the component according to thickness of samples made of aluminium.Temporary resolution ranges of electric and magnetic properties and defects of sample continuity along the depth have been found.Empirical formulae of dependence Hτm on sample thickness have been derived and their relation with efficient depth penetration of magnetic field into metal has been found.

  11. Sensitivity Range Analysis of Infrared (IR) Transmitter and Receiver Sensor to Detect Sample Position in Automatic Sample Changer

    International Nuclear Information System (INIS)

    Syirrazie Che Soh; Nolida Yussup; Nur Aira Abdul Rahman; Maslina Ibrahim

    2016-01-01

    Sensitivity range of IR Transmitter and Receiver Sensor influences the effectiveness of the sensor to detect position of a sample. Then the purpose of this analysis is to determine the suitable design and specification the electronic driver of the sensor to gain appropriate sensitivity range for required operation. The related activities to this analysis cover electronic design concept and specification, calibration of design specification and evaluation on design specification for required application. (author)

  12. Long-range effect in nitrogen ion-implanted AISI 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Budzynski, P., E-mail: p.budzynski@pollub.pl

    2015-01-01

    The effect of nitrogen ion implantation on AISI 316L stainless steel was investigated. The microstructure and composition of an N implanted layer were studied by RBS, GIXRD, SEM, and EDX measurements. Friction and wear tests were also performed. The discrepancy between the measured and calculated stopped ion maximum range does not exceed 0.03 μm. After nitrogen implantation with a fluence of 5 × 10{sup 17} ion/cm{sup 2}, additional phases of expanded austenite were detected. At a 5-fold larger depth than the maximum ion range, improvement in the coefficient of friction and wear was detected. We have shown, for the first time, the long-range effect in tribological investigations. The long-range effect is caused by movement of not only defects along the depth of the sample, as assumed so far, but also nitrogen atoms.

  13. Long-range effect in nitrogen ion-implanted AISI 316L stainless steel

    Science.gov (United States)

    Budzynski, P.

    2015-01-01

    The effect of nitrogen ion implantation on AISI 316L stainless steel was investigated. The microstructure and composition of an N implanted layer were studied by RBS, GIXRD, SEM, and EDX measurements. Friction and wear tests were also performed. The discrepancy between the measured and calculated stopped ion maximum range does not exceed 0.03 μm. After nitrogen implantation with a fluence of 5 × 1017 ion/cm2, additional phases of expanded austenite were detected. At a 5-fold larger depth than the maximum ion range, improvement in the coefficient of friction and wear was detected. We have shown, for the first time, the long-range effect in tribological investigations. The long-range effect is caused by movement of not only defects along the depth of the sample, as assumed so far, but also nitrogen atoms.

  14. Multielemental analysis of soil samples from the Assin District of Central Region in Ghana using nuclear and related techniques

    International Nuclear Information System (INIS)

    Agyemang, O.

    2008-06-01

    Macronutrients, micronutrients, pH, salinity and moisture content were determined in soil samples from six farms in two farming towns in Assin North District in the Central Region of Ghana namely Assin Akonfudi and Assin Bereku. Soil samples were taken from cocoa farms, orange farms and palm oil plantations at three different depths. The nutrients determined were Primary macronutrients that was K, Secondary macronutrients that were Ca, Mg and Micronutrients that were, Cl, Co, Cu, Fe, Mn, Mo, Zn, Na and Se and Neutron Activation method and Atomic Absorption Spectrometry were used for the elemental analysis. The pHs were within the acidic range, ranging from 4.50-6.44. The top soil (0-5cm) had the higher pH followed by soil at the depth of 5-30cm and then soil at the depth of 30-40cm that is the pH decreased with depth. The salinity rather increased with depth ranging from 0.3l-2.98dS/m and the moisture content also ranged from 0.5-2.04%. For the soil samples taken from the cocoa farms, K recorded the highest concentration and Mo recorded the lowest concentration in the soil. For soil samples taken from orange farms, Ca recorded the highest concentration and Se recorded the lowest concentration in the soil and for soil samples taken from the palm oil plantations, Fe recorded the highest concentration and Mo recorded the lowest concentration in soil. The macronutrients ranged from 28591.19-6.49 mg/kg and the micronutrients ranged from <0.0004-20344.50 mg/kg. Soils in the cocoa farms were found to be more rich in nutrients and the soils in the palm oil plantations were found to be least rich in nutrients

  15. Elemental Geochemistry of Samples From Fault Segments of the San Andreas Fault Observatory at Depth (SAFOD) Drill Hole

    Science.gov (United States)

    Tourscher, S. N.; Schleicher, A. M.; van der Pluijm, B. A.; Warr, L. N.

    2006-12-01

    Elemental geochemistry of mudrock samples from phase 2 drilling of the San Andreas Fault Observatory at Depth (SAFOD) is presented from bore hole depths of 3066 m to 3169 m and from 3292 m to 3368 m, which contain a creeping section and main trace of the fault, respectively. In addition to preparation and analysis of whole rock sample, fault grains with neomineralized, polished surfaces were hand picked from well-washed whole rock samples, minimizing the potential contamination from drilling mud and steel shavings. The separated fractions were washed in deionized water, powdered using a mortar and pestle, and analyzed using an Inductively Coupled Plasma- Optical Emission Spectrometer for major and minor elements. Based on oxide data results, systematic differences in element concentrations are observed between the whole rock and fault rock. Two groupings of data points are distinguishable in the regions containing the main trace of the fault, a shallow part (3292- 3316 m) and a deeper section (3320-3368 m). Applying the isocon method, assuming Zr and Ti to be immobile elements in these samples, indicates a volume loss of more than 30 percent in the shallow part and about 23 percent in the deep part of the main trace. These changes are minimum estimates of fault-related volume loss, because the whole rock from drilling samples contains variable amount of fault rock as well. Minimum estimates for volume loss in the creeping section of the fault are more than 50 percent when using the isocon method, comparing whole rock to plucked fault rock. The majority of the volume loss in the fault rocks is due to the dissolution and loss of silica, potassium, aluminum, sodium and calcium, whereas (based on oxide data) the mineralized surfaces of fractures appear to be enriched in Fe and Mg. The large amount of element mobility within these fault traces suggests extensive circulation of hydrous fluids along fractures that was responsible for progressive dissolution and leaching

  16. Plasma lactate concentrations in free-ranging moose (Alces alces) immobilized with etorphine.

    Science.gov (United States)

    Haga, Henning A; Wenger, Sandra; Hvarnes, Silje; Os, Oystein; Rolandsen, Christer M; Solberg, Erling J

    2009-11-01

    To investigate plasma lactate concentrations of etorphine-immobilized moose in relation to environmental, temporal and physiological parameters. Prospective clinical study. Fourteen female and five male moose (Alces alces), estimated age range 1-7 years. The moose were darted from a helicopter with 7.5 mg etorphine per animal using projectile syringes and a dart gun. Once immobilized, the moose were approached, a venous blood sample was obtained and vital signs including pulse oximetry were recorded. Diprenorphine was administered to reverse the effects of etorphine. Timing of events, ambient temperature and snow depth were recorded. Blood samples were cooled and centrifuged before plasma was harvested and frozen. The plasma was thawed later and lactate analysed. Data were analysed using descriptive statistics and regression analysis. All animals recovered uneventfully and were alive 12 weeks after immobilization. Mean +/- SD plasma lactate was found to be 9.2 +/- 2.1 mmol L(-1). Plasma lactate concentrations were related positively to snow depth and negatively to time from induction of immobilization to blood sampling. The model that best described the variability in plasma lactate concentrations used induction time (time from firing the dart to the moose being immobilized). The second best model included induction time and snow depth. Plasma lactate concentrations in these etorphine-immobilized moose were in the range reported for other immobilized wild ruminants. Decreasing induction time, which may be related to a more profound etorphine effect, and increasing snow depth possibly may increase plasma lactate concentrations in etorphine-immobilized moose.

  17. Cigarette Mouth Insertion Depths Among Chinese Smokers

    Directory of Open Access Journals (Sweden)

    Hu Q

    2014-12-01

    Full Text Available Vent blocking - where filter ventilation holes are intentionally or unintentionally, partly or completely covered by smokers’ lips during smoking - is an aspect of smoking behavior which can alter mainstream smoke yields. This study was designed to determine if, and to what extent ventilation holes were blocked by smokers’ lips in two cohorts of Chinese smokers. In this study, two groups of samples were collected. One group (1742 butts was collected randomly from public places in six chosen cities. Another (1037 butts was obtained by collecting the butts from identified smokers in Kunming. In this paper, the mouth insertion depth among Chinese smokers was studied for the first time by a staining method employing ninhydrin in ethanol. The results indicate that Chinese smokers exhibit a mouth insertion depth ranging from 1 to 17 mm with an average value of 7.5 AA± 2 mm. In this study, 95% of the ventilated filters examined showed that the vent zone was neither completely nor partially covered by smokers’ lips.

  18. SIMS depth profile analysis of environmental microparticles

    International Nuclear Information System (INIS)

    Konarski, P.

    2000-01-01

    Environmental and technological research demands chemical characterization of aerosol particles so minute in size, that conventional methods for bulk analyses are simply not applicable. In this work novel application of secondary ion mass spectrometry (SIMS) for characterization of microparticles suspended in atmosphere of the working environment of glass plant Thomson Polkolor, Piaseczno and steelworks Huta Sendzimira, Cracow is presented. The new technique based on sample rotation in depth profile analysis of sub-micrometer particulate material was performed on SAJW-02 analyser equipped with Balzers 16 mm quadrupole spectrometer and sample rotation manipulator using 5 keV Ar + and O 2 + ion beams. The results were compared with the standard method used on ims-3f Cameca analyser 12 keV O 2 + ion beam. Grain size distributions of aerosol microparticles were estimated using eight-stage cascade impactor with particle size range of 0.2 μm to 15 μm. Elemental concentration and crystalline structure of the collected dust particles were performed using spark source mass spectrometry and X-ray diffraction methods. SIMS depth profile analysis shows that sub-micrometer particles do not have uniform morphology, The core-shell structure has been observed for particles collected in both factories. Presented models show that the steelworks particles consists mainly of iron and manganese cores. At the shells of these microparticles :lead, chlorine and fluorine are found. The cores of glass plant submicrometer particles consists mainly of lead-zirconium glass covered by a shell containing carbon and copper. Sample rotation technique applied SIMS appears to be an effective tool for environmental microparticle morphology studies. (author)

  19. Dual beam organic depth profiling using large argon cluster ion beams

    Science.gov (United States)

    Holzweber, M; Shard, AG; Jungnickel, H; Luch, A; Unger, WES

    2014-01-01

    Argon cluster sputtering of an organic multilayer reference material consisting of two organic components, 4,4′-bis[N-(1-naphthyl-1-)-N-phenyl- amino]-biphenyl (NPB) and aluminium tris-(8-hydroxyquinolate) (Alq3), materials commonly used in organic light-emitting diodes industry, was carried out using time-of-flight SIMS in dual beam mode. The sample used in this study consists of a ∽400-nm-thick NPB matrix with 3-nm marker layers of Alq3 at depth of ∽50, 100, 200 and 300 nm. Argon cluster sputtering provides a constant sputter yield throughout the depth profiles, and the sputter yield volumes and depth resolution are presented for Ar-cluster sizes of 630, 820, 1000, 1250 and 1660 atoms at a kinetic energy of 2.5 keV. The effect of cluster size in this material and over this range is shown to be negligible. © 2014 The Authors. Surface and Interface Analysis published by John Wiley & Sons Ltd. PMID:25892830

  20. Radon exhalation rates from slate stone samples in Aravali Range in Haryana

    International Nuclear Information System (INIS)

    Upadhyay, S.B.; Kant, K.; Chakarvarti, S.K.

    2012-01-01

    The slate stone tiles are very popular in covering the walls of the rooms. Radon is released into ambient air from slate stones due to ubiquitous uranium and radium in them, thus increasing the airborne radon concentration. The radioactivity in slates stones is related to radioactivity in the rocks from which the slate stone tiles are formed. In the present investigation, the radon emanated from slate stone samples collected from different slate mines in Aravali range of hills in the Haryana state of Northern India has been estimated. For the measurement of radon concentration emanated from these samples, alpha-sensitive LR-115 type II plastic track detectors have been used. The alpha particles emitted from the radon form tracks in these detectors. After chemical etching the track density of registered tracks is used to calculate radon concentration and exhalation rates of radon using required formulae. The measurements indicate normal to some higher levels of radon concentration emanated from the slat stone samples collected from Aravali range of hills in north India. The results will be discussed in full paper. (author)

  1. The Spatial Variability of Beryllium-7 Depth Distribution Study

    International Nuclear Information System (INIS)

    Jalal Sharib; Zainudin Othman; Dainee Nor Fardzila Ahmad Tugi; Noor Fadzilah Yusof; Mohd Tarmizi Ishak

    2015-01-01

    The objective of this paper is to study the spatial variability of 7 Be depth evolution in soil profile at two different sampling sites. The soil samples have been collected by using metal core in bare area in Bangi, Selangor and Timah Tasoh, Perlis , Malaysia. Two composite core samples for each sampling sites has been sectioned into 2 mm increments to a depth of 4 cm and oven dried at 45- 60 degree Celsius and gently desegregated. These two composite spatial samples are passed through a < 2 mm sieve and packed into proper geometry plastic container for 7 Be analysis by using gamma spectrometry with a 24-hour count time. From the findings, the 7 Be content in the soil samples from Bangi, Selangor study area is distributed lower depth penetration into the soil profile than Timah Tasoh, Perlis catchment due to many factors such as precipitation (fallout) and others. However, the spatial variability from both samples study area is also decreases exponentially with depth and is confined within the top few centimeters and similar with other works been reported (Blake et al., (2000) and Walling et al.,(2008). Furthermore, a detailed discussion from this study findings will be in full papers. (author)

  2. Tensor-guided fitting of subduction slab depths

    Science.gov (United States)

    Bazargani, Farhad; Hayes, Gavin P.

    2013-01-01

    Geophysical measurements are often acquired at scattered locations in space. Therefore, interpolating or fitting the sparsely sampled data as a uniform function of space (a procedure commonly known as gridding) is a ubiquitous problem in geophysics. Most gridding methods require a model of spatial correlation for data. This spatial correlation model can often be inferred from some sort of secondary information, which may also be sparsely sampled in space. In this paper, we present a new method to model the geometry of a subducting slab in which we use a data‐fitting approach to address the problem. Earthquakes and active‐source seismic surveys provide estimates of depths of subducting slabs but only at scattered locations. In addition to estimates of depths from earthquake locations, focal mechanisms of subduction zone earthquakes also provide estimates of the strikes of the subducting slab on which they occur. We use these spatially sparse strike samples and the Earth’s curved surface geometry to infer a model for spatial correlation that guides a blended neighbor interpolation of slab depths. We then modify the interpolation method to account for the uncertainties associated with the depth estimates.

  3. Effective sampling range of food-based attractants for female Anastrepha suspensa (Diptera: Tephritidae).

    Science.gov (United States)

    Kendra, Paul E; Epsky, Nancy D; Heath, Robert R

    2010-04-01

    Release-recapture studies were conducted with both feral and sterile females of the Caribbean fruit fly, Anastrepha suspensa (Loew) (Diptera: Tephritidae), to determine sampling range for a liquid protein bait (torula yeast/borax) and for a two-component synthetic lure (ammonium acetate and putrescine). Tests were done in a guava, Psidium guajava L., grove and involved releasing flies at a central point and recording the numbers captured after 7 h and 1, 2, 3, and 6 d in an array of 25 Multilure traps located 9-46 m from the release point. In all tests, highest rate of recapture occurred within the first day of release, so estimations of sampling range were based on a 24-h period. Trap distances were grouped into four categories (30 m from release point) and relative trapping efficiency (percentage of capture) was determined for each distance group. Effective sampling range was defined as the maximum distance at which relative trapping efficiency was > or = 25%. This corresponded to the area in which 90% of the recaptures occured. Contour analysis was also performed to document spatial distribution of fly dispersal. In tests with sterile flies, immature females dispersed farther and were recovered in higher numbers than mature females, regardless of attractant, and recapture of both cohorts was higher with torula yeast. For mature feral flies, range of the synthetic lure was determined to be 30 m. With sterile females, effective range of both attractants was 20 m. Contour maps indicated that wind direction had a strong influence on the active space of attractants, as reflected by distribution of captured flies.

  4. Rescaled Range Analysis and Detrended Fluctuation Analysis: Finite Sample Properties and Confidence Intervals

    Czech Academy of Sciences Publication Activity Database

    Krištoufek, Ladislav

    4/2010, č. 3 (2010), s. 236-250 ISSN 1802-4696 R&D Projects: GA ČR GD402/09/H045; GA ČR GA402/09/0965 Grant - others:GA UK(CZ) 118310 Institutional research plan: CEZ:AV0Z10750506 Keywords : rescaled range analysis * detrended fluctuation analysis * Hurst exponent * long-range dependence Subject RIV: AH - Economics http://library.utia.cas.cz/separaty/2010/E/kristoufek-rescaled range analysis and detrended fluctuation analysis finite sample properties and confidence intervals.pdf

  5. Total Variation Depth for Functional Data

    KAUST Repository

    Huang, Huang

    2016-11-15

    There has been extensive work on data depth-based methods for robust multivariate data analysis. Recent developments have moved to infinite-dimensional objects such as functional data. In this work, we propose a new notion of depth, the total variation depth, for functional data. As a measure of depth, its properties are studied theoretically, and the associated outlier detection performance is investigated through simulations. Compared to magnitude outliers, shape outliers are often masked among the rest of samples and harder to identify. We show that the proposed total variation depth has many desirable features and is well suited for outlier detection. In particular, we propose to decompose the total variation depth into two components that are associated with shape and magnitude outlyingness, respectively. This decomposition allows us to develop an effective procedure for outlier detection and useful visualization tools, while naturally accounting for the correlation in functional data. Finally, the proposed methodology is demonstrated using real datasets of curves, images, and video frames.

  6. Depth profiling: RBS versus energy-dispersive X-ray imaging using scanning transmission electron microscopy

    International Nuclear Information System (INIS)

    Markwitz, Andreas

    2000-01-01

    Rutherford backscattering spectrometry (RBS) is known to be one of the techniques ideal for analysis of thin films. Elemental concentrations of matrix components and impurities can be investigated as well as depth profiles of almost each element of the periodic table. Best of all, RBS has both a high sensitivity and a high depth resolution, and is a non-destructive analysis technique that does not require specific sample preparation. Solid-state samples are mounted without preparation inside a high-vacuum analysis chamber. However, depth-related interpretation of elemental depth profiles requires the material density of the specimen and stopping power values to be taken into consideration. In many cases, these parameters can be estimated with sufficient precision. However, the assumed density can be inaccurate for depth scales in the nanometer range. For example, in the case of Ge nanoclusters in 500 nm thick SiO 2 layers, uncertainty is related to the actual position of a very thin Ge nanocluster band. Energy-dispersive X-ray emission (EDX) spectroscopy, using a high-resolution scanning transmission electron microscope (STEM) can assist in removing this uncertainty. By preparing a thin section of the specimen, EDX can be used to identify the position of the Ge nanocluster band very precisely, by correlating the Ge profile with the depth profiles of silicon and oxygen. However, extraction of the concentration profiles from STEM-EDX spectra is in general not straightforward. Therefore, a combination of the two very different analysis techniques is often the best and only successful way to extract high-resolution concentration profiles

  7. Sampling methods

    International Nuclear Information System (INIS)

    Loughran, R.J.; Wallbrink, P.J.; Walling, D.E.; Appleby, P.G.

    2002-01-01

    Methods for the collection of soil samples to determine levels of 137 Cs and other fallout radionuclides, such as excess 210 Pb and 7 Be, will depend on the purposes (aims) of the project, site and soil characteristics, analytical capacity, the total number of samples that can be analysed and the sample mass required. The latter two will depend partly on detector type and capabilities. A variety of field methods have been developed for different field conditions and circumstances over the past twenty years, many of them inherited or adapted from soil science and sedimentology. The use of them inherited or adapted from soil science and sedimentology. The use of 137 Cs in erosion studies has been widely developed, while the application of fallout 210 Pb and 7 Be is still developing. Although it is possible to measure these nuclides simultaneously, it is common for experiments to designed around the use of 137 Cs along. Caesium studies typically involve comparison of the inventories found at eroded or sedimentation sites with that of a 'reference' site. An accurate characterization of the depth distribution of these fallout nuclides is often required in order to apply and/or calibrate the conversion models. However, depending on the tracer involved, the depth distribution, and thus the sampling resolution required to define it, differs. For example, a depth resolution of 1 cm is often adequate when using 137 Cs. However, fallout 210 Pb and 7 Be commonly has very strong surface maxima that decrease exponentially with depth, and fine depth increments are required at or close to the soil surface. Consequently, different depth incremental sampling methods are required when using different fallout radionuclides. Geomorphic investigations also frequently require determination of the depth-distribution of fallout nuclides on slopes and depositional sites as well as their total inventories

  8. Depth resolution of secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Pustovit, A.N.

    2004-01-01

    The effect of the solid body discreteness in the direction of the normal to the sample surface on the depth resolution of the secondary ion mass spectrometry method is analyzed. It is shown that for this case the dependence of the width at the semi-height of the delta profiles of the studied elements depth distribution on the energy and angle of incidence of the initial ions should have the form of the stepwise function. This is experimentally proved by the silicon-germanium delta-layers in the silicon samples [ru

  9. Weak layer fracture: facets and depth hoar

    Directory of Open Access Journals (Sweden)

    I. Reiweger

    2013-09-01

    Full Text Available Understanding failure initiation within weak snow layers is essential for modeling and predicting dry-snow slab avalanches. We therefore performed laboratory experiments with snow samples containing a weak layer consisting of either faceted crystals or depth hoar. During these experiments the samples were loaded with different loading rates and at various tilt angles until fracture. The strength of the samples decreased with increasing loading rate and increasing tilt angle. Additionally, we took pictures of the side of four samples with a high-speed video camera and calculated the displacement using a particle image velocimetry (PIV algorithm. The fracture process within the weak layer could thus be observed in detail. Catastrophic failure started due to a shear fracture just above the interface between the depth hoar layer and the underlying crust.

  10. Change of Precipitation Behavior and Impact Toughness with Depths in Quenched Thick SAF 2507 Super Duplex Stainless Steel

    Science.gov (United States)

    Ahiale, Godwin Kwame; Kim, Doo-Hyun; Yang, Won-Jon; Lee, Jong-Hoon; Oh, Yong-Jun

    2018-03-01

    We investigated the change of precipitation behavior and impact resistance as a function of depth from the surface of thick block of SAF 2507 super duplex stainless steel with the thickness (T) of 200 mm after water quenching from 1050 °C. The amount of detrimental sigma phase increased smoothly until the depth of 0.25T, followed by a rapid increase from 0.25T to the center. However, the impact strength decreased significantly with only 1.3% of area fraction of sigma phase as the depth increased past 0.1T. Based on fractography analysis for the samples at such small depth ranges, the distance between the sigma phase particles affected the relative amount of initiating brittle cracks in front of the notch and was one of the crucial factors that dramatically reduced impact resistance with depth.

  11. The Beryllium-7 Depth Study in Different Land Use

    International Nuclear Information System (INIS)

    Jalal Sharib; Zainudin Othman; Dainee Nor Fardzila Ahmad Tugi; Noor Fadzilah Yusof; Mohd Tarmizi Ishak

    2015-01-01

    The main objective for this study is to evaluate the evolution of 7 Be depth distribution in soil profile at Tasoh Catchment area, Perlis, Malaysia which area has been different land use. The soil samples for this study have been carried out in Timah surroundings by different agricultural land use. Therefore, three different types of soil samples from different land use have been collected by using metal core and have been sectioned into 2 mm increments to a depth of 4 cm. The samples were brought to Radiochemistry and Environment Group Laboratory (RAS), Bangi for further treatment. The samples subsequently oven dried at 45-60 degree Celsius and gently desegregated. The sample is passed through a < 2 mm sieve and packed into geometry plastic container for 7 Be analysis by using gamma spectrometry with a 24-hour count time. From the findings show that the 7 Be soil samples are penetrated with decreases exponentially with depth and is confined within the top few centimeters at most and similar with other works been reported (Blake et al., 2000 and Walling et al., 2008). , the 7 Be from mixed land use also shows more deeper penetration into the soil depth than from two others land use due to a several factors. Therefore, further and detailed discussion for these findings will be described in full paper. (author)

  12. Underwater Ranging

    OpenAIRE

    S. P. Gaba

    1984-01-01

    The paper deals with underwater laser ranging system, its principle of operation and maximum depth capability. The sources of external noise and methods to improve signal-to-noise ratio are also discussed.

  13. Roughness development in the depth profiling with 500 eV O2+ beam with the combination of oxygen flooding and sample rotation

    International Nuclear Information System (INIS)

    Gui, D.; Xing, Z.X.; Huang, Y.H.; Mo, Z.Q.; Hua, Y.N.; Zhao, S.P.; Cha, L.Z.

    2008-01-01

    Roughness development is one of the most often addressed issues in the secondary ion mass spectrometry (SIMS) ultra-shallow depth profiling. The effect of oxygen flooding pressure on the roughness development has been investigated under the bombardment of 500 eV O 2 + beam with simultaneous sample rotation. Oxygen flooding had two competing effects on the surface roughening, i.e., enhancement of initiating roughening and suppression of roughening development, which were suggested to be described by the onset depth z on and transient width w tr of surface roughening. Both z on and w tr decreased as oxygen flooding pressure increased. As the result, surface roughening was most pronounced at the intermediate pressure from 4.4E-5 Pa to 5.8E-5 Pa. The surface roughening is negligible while without flooding or with flooding at the saturated pressure. No flooding is preferable for depth profiling ultra-shallow B implantation because of the better B profile shape and short analysis time

  14. Magma transport and olivine crystallization depths in Kīlauea's east rift zone inferred from experimentally rehomogenized melt inclusions

    Science.gov (United States)

    Tuohy, Robin M.; Wallace, Paul J.; Loewen, Matthew W.; Swanson, Donald A.; Kent, Adam J. R.

    2016-07-01

    Concentrations of H2O and CO2 in olivine-hosted melt inclusions can be used to estimate crystallization depths for the olivine host. However, the original dissolved CO2 concentration of melt inclusions at the time of trapping can be difficult to measure directly because in many cases substantial CO2 is transferred to shrinkage bubbles that form during post-entrapment cooling and crystallization. To investigate this problem, we heated olivine from the 1959 Kīlauea Iki and 1960 Kapoho (Hawai'i) eruptions in a 1-atm furnace to temperatures above the melt inclusion trapping temperature to redissolve the CO2 in shrinkage bubbles. The measured CO2 concentrations of the experimentally rehomogenized inclusions (⩽590 ppm for Kīlauea Iki [n = 10]; ⩽880 ppm for Kapoho, with one inclusion at 1863 ppm [n = 38]) overlap with values for naturally quenched inclusions from the same samples, but experimentally rehomogenized inclusions have higher within-sample median CO2 values than naturally quenched inclusions, indicating at least partial dissolution of CO2 from the vapor bubble during heating. Comparison of our data with predictions from modeling of vapor bubble formation and published Raman data on the density of CO2 in the vapor bubbles suggests that 55-85% of the dissolved CO2 in the melt inclusions at the time of trapping was lost to post-entrapment shrinkage bubbles. Our results combined with the Raman data demonstrate that olivine from the early part of the Kīlauea Iki eruption crystallized at <6 km depth, with the majority of olivine in the 1-3 km depth range. These depths are consistent with the interpretation that the Kīlauea Iki magma was supplied from Kīlauea's summit magma reservoir (∼2-5 km depth). In contrast, olivine from Kapoho, which was the rift zone extension of the Kīlauea Iki eruption, crystallized over a much wider range of depths (∼1-16 km). The wider depth range requires magma transport during the Kapoho eruption from deep beneath the summit

  15. Λ and Σ well depth

    International Nuclear Information System (INIS)

    Satoh, Eiji

    1982-01-01

    The Λ well depth was calculated by taking into account the effect of the ΛΣ conversion. Takahashi et al. obtained the separate type of potentials which described the hyperon-nucleon interaction up to p waves. Two types of the potentials among several types they obtained were used to calculate the Λ well depth. The G matrix was easily calculated, and the Λ well depth was obtained by integrating the G matrix in momentum space up to the Fermi surface. The effect of the ΛΣ conversion was given by an equation. The total Λ well depth was estimated to be 9.13 MeV and 49.36 MeV for each type of potential, respectively. It was concluded that the argument by Bodmer et al. was not correct. The Σ well depth was also calculated using the potential obtained by Takahashi et al. for I = 1/2 and the one obtained by Σ + p → Σ + p scattering data for I = 3/2. The obtained value 35.30 MeV may be overestimated, and the experimental value is expected to be in the range from 20 MeV to 30 MeV. (Ito, K.)

  16. Optimizing visual comfort for stereoscopic 3D display based on color-plus-depth signals.

    Science.gov (United States)

    Shao, Feng; Jiang, Qiuping; Fu, Randi; Yu, Mei; Jiang, Gangyi

    2016-05-30

    Visual comfort is a long-facing problem in stereoscopic 3D (S3D) display. In this paper, targeting to produce S3D content based on color-plus-depth signals, a general framework for depth mapping to optimize visual comfort for S3D display is proposed. The main motivation of this work is to remap the depth range of color-plus-depth signals to a new depth range that is suitable to comfortable S3D display. Towards this end, we first remap the depth range globally based on the adjusted zero disparity plane, and then present a two-stage global and local depth optimization solution to solve the visual comfort problem. The remapped depth map is used to generate the S3D output. We demonstrate the power of our approach on perceptually uncomfortable and comfortable stereoscopic images.

  17. Impeller Submergence Depth for Stirred Tanks

    Directory of Open Access Journals (Sweden)

    Thiyam T. Devi

    2011-11-01

    Full Text Available Impeller submergence governs the performance of mixing tanks employed in oxygen transfer operation. Present work experimentally investigates the effect of impeller submergence depths on oxygen transfer and corresponding power consumption. It has been found that at higher range of impeller submergence, mixing tanks consume less power and gives higher values of oxygen transfer coefficient. Optimal range of submergence depth is 0.7 to 0.9 times the impeller diameter. Copyright ©2011 BCREC UNDIP. All rights reserved.(Received: 4th March 2011; Revised: 12nd July 2011; Accepted: 14th July 2011[How to Cite: T.T. Devi, A.P. Sinha, M. Thakre, and B. Kumar. (2011. Impeller Submergence Depth for Stirred Tanks. Bulletin of Chemical Reaction Engineering & Catalysis, 6 (2: 123-128. doi:10.9767/bcrec.6.2.826.123-128][How to Link / DOI: http://dx.doi.org/10.9767/bcrec.6.2.826.123-128 || or local: http://ejournal.undip.ac.id/index.php/bcrec/article/view/826] | View in 

  18. Chalk porosity and sonic velocity versus burial depth

    DEFF Research Database (Denmark)

    Fabricius, Ida Lykke; Gommesen, Lars; Krogsbøll, Anette Susanne

    2008-01-01

    Seventy chalk samples from four formations in the overpressured Danish central North Sea have been analyzed to investigate how correlations of porosity and sonic velocity with burial depth are affected by varying mineralogy, fluid pressure, and early introduction of petroleum. The results show th...... for fluid pressure because the cementing ions originate from stylolites, which are mechanically similar to fractures. We find that cementation occurs over a relatively short depth interval.......Seventy chalk samples from four formations in the overpressured Danish central North Sea have been analyzed to investigate how correlations of porosity and sonic velocity with burial depth are affected by varying mineralogy, fluid pressure, and early introduction of petroleum. The results show...... that porosity and sonic velocity follow the most consistent depth trends when fluid pressure and pore-volume compressibility are considered. Quartz content up to 10% has no marked effect, but more than 5% clay causes lower porosity and velocity. The mineralogical effect differs between P-wave and shear velocity...

  19. Testing a groundwater sampling tool: Are the samples representative?

    International Nuclear Information System (INIS)

    Kaback, D.S.; Bergren, C.L.; Carlson, C.A.; Carlson, C.L.

    1989-01-01

    A ground water sampling tool, the HydroPunch trademark, was tested at the Department of Energy's Savannah River Site in South Carolina to determine if representative ground water samples could be obtained without installing monitoring wells. Chemical analyses of ground water samples collected with the HydroPunch trademark from various depths within a borehole were compared with chemical analyses of ground water from nearby monitoring wells. The site selected for the test was in the vicinity of a large coal storage pile and a coal pile runoff basin that was constructed to collect the runoff from the coal storage pile. Existing monitoring wells in the area indicate the presence of a ground water contaminant plume that: (1) contains elevated concentrations of trace metals; (2) has an extremely low pH; and (3) contains elevated concentrations of major cations and anions. Ground water samples collected with the HydroPunch trademark provide in excellent estimate of ground water quality at discrete depths. Groundwater chemical data collected from various depths using the HydroPunch trademark can be averaged to simulate what a screen zone in a monitoring well would sample. The averaged depth-discrete data compared favorably with the data obtained from the nearby monitoring wells

  20. Evaluating methods for controlling depth perception in stereoscopic cinematography

    Science.gov (United States)

    Sun, Geng; Holliman, Nick

    2009-02-01

    Existing stereoscopic imaging algorithms can create static stereoscopic images with perceived depth control function to ensure a compelling 3D viewing experience without visual discomfort. However, current algorithms do not normally support standard Cinematic Storytelling techniques. These techniques, such as object movement, camera motion, and zooming, can result in dynamic scene depth change within and between a series of frames (shots) in stereoscopic cinematography. In this study, we empirically evaluate the following three types of stereoscopic imaging approaches that aim to address this problem. (1) Real-Eye Configuration: set camera separation equal to the nominal human eye interpupillary distance. The perceived depth on the display is identical to the scene depth without any distortion. (2) Mapping Algorithm: map the scene depth to a predefined range on the display to avoid excessive perceived depth. A new method that dynamically adjusts the depth mapping from scene space to display space is presented in addition to an existing fixed depth mapping method. (3) Depth of Field Simulation: apply Depth of Field (DOF) blur effect to stereoscopic images. Only objects that are inside the DOF are viewed in full sharpness. Objects that are far away from the focus plane are blurred. We performed a human-based trial using the ITU-R BT.500-11 Recommendation to compare the depth quality of stereoscopic video sequences generated by the above-mentioned imaging methods. Our results indicate that viewers' practical 3D viewing volumes are different for individual stereoscopic displays and viewers can cope with much larger perceived depth range in viewing stereoscopic cinematography in comparison to static stereoscopic images. Our new dynamic depth mapping method does have an advantage over the fixed depth mapping method in controlling stereo depth perception. The DOF blur effect does not provide the expected improvement for perceived depth quality control in 3D cinematography

  1. Depth profiles of defects in Ar-iondashirradiated steels determined by a least-squares fit of S parameters from variable-energy positron annihilation

    Science.gov (United States)

    Aruga, Takeo; Takamura, Saburo; Nakata, Kiyotomo; Ito, Yasuo

    1995-01-01

    Using a new method for reconstructing the depth profile of defects in an iondashirradiated sample by using slow positrons, the depth profiles of vacancy-type defects in 316 stainless steel samples, irradiated with 250 keV Ar ions to a dose of 7.5 × 10 19 m -2 at room temperature, have been calculated from Doppler-broadening S parameters measured as a function of positron energies up to 16 keV. Without assuming any type of shape for the defect profiles, such as Gaussian, the defect profiling is done using a least-squares fitting method. The resulting profile suggests that in as-irradiated 316 stainless steel samples with lower carbon content, the defect distribution peaks at a depth four times larger than that of the ion range. After annealing at a high temperature of 1253 K for 0.5 h, the fitted profile shows that the peak around the average ion range is highly enhanced. While in the steel added with 0.3 wt% titanium, the profile exhibits almost no peak after annealing at 1073 K. The results indicate that the radiationdashproduced vacancy clusters are stabilized by the implanted Ar atoms more effectively in the Ti-free steel than in the Ti-added steel.

  2. Procedure for determining the optimum rate of increasing shaft depth

    Energy Technology Data Exchange (ETDEWEB)

    Durov, E.M.

    1983-03-01

    Presented is an economic analysis of increasing shaft depth during mine modernization. Investigations carried out by the Yuzhgiproshakht Institute are analyzed. The investigations are aimed at determining the optimum shaft sinking rate (the rate which reduces investment to the minimum). The following factors are considered: coal output of a mine (0.9, 1.2, 1.5 and 1.8 Mt/year), depth at which the new mining level is situated (600, 800, 1200, 1400 and 1600 m), four schemes of increasing depth of 2 central shafts (rock hoisting to ground surface, rock hoisting to the existing level, rock haulage to the developed level, rock haulage to the level being developed using a large diameter borehole drilled from the new level to the shaft bottom and enlarged from shaft bottom to the new level), shaft sinking rate (10, 20, 30, 40, 50 and 60 m/month), range of increasing shaft depth (the difference between depth of the shaft before and after increasing its depth by 100, 200, 300 and 400 m). Comparative evaluations show that the optimum shaft sinking rate depends on the scheme for rock hoisting (one of 4 analyzed), range of increasing shaft depth and gas content in coal seams. The optimum shaft sinking rate ranges from 20 to 40 m/month in coal mines with low methane content and from 20 to 30 m/month in gassy coal mines. The planned coal output of a mine does not influence the optimum shaft sinking rate.

  3. Structural changes and out-of-sample prediction of realized range-based variance in the stock market

    Science.gov (United States)

    Gong, Xu; Lin, Boqiang

    2018-03-01

    This paper aims to examine the effects of structural changes on forecasting the realized range-based variance in the stock market. Considering structural changes in variance in the stock market, we develop the HAR-RRV-SC model on the basis of the HAR-RRV model. Subsequently, the HAR-RRV and HAR-RRV-SC models are used to forecast the realized range-based variance of S&P 500 Index. We find that there are many structural changes in variance in the U.S. stock market, and the period after the financial crisis contains more structural change points than the period before the financial crisis. The out-of-sample results show that the HAR-RRV-SC model significantly outperforms the HAR-BV model when they are employed to forecast the 1-day, 1-week, and 1-month realized range-based variances, which means that structural changes can improve out-of-sample prediction of realized range-based variance. The out-of-sample results remain robust across the alternative rolling fixed-window, the alternative threshold value in ICSS algorithm, and the alternative benchmark models. More importantly, we believe that considering structural changes can help improve the out-of-sample performances of most of other existing HAR-RRV-type models in addition to the models used in this paper.

  4. Depth-resolution imaging of crystalline nanoclusters attached on and embedded in amorphous films using aberration-corrected TEM

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Jun, E-mail: yamasaki@uhvem.osaka-u.ac.jp [Research Center for Ultra-High Voltage Electron Microscopy, Osaka University, 7-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); EcoTopia Science Institute, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Mori, Masayuki [Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Hirata, Akihiko [Advanced Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Hirotsu, Yoshihiko [Institute of Scientific and Industrial Research, Osaka University, 8-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Tanaka, Nobuo [EcoTopia Science Institute, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2015-04-15

    For observations of crystalline nanoclusters, the features and capabilities of depth-resolution imaging by aberration-corrected transmission electron microscopy (TEM) were investigated using image simulations and experiments for two types of samples. The first sample was gold clusters attached on an amorphous carbon film. The experimental through-focal series indicated that the focal plane for the cluster was shifted 3 nm from that for the supporting film. This difference is due to the depth-resolution imaging of the cluster and film, the mid-planes of which are separated by 3 nm along the depth direction (the electron incident direction). On the basis of this information, the three-dimensional configuration of the sample, such as the film thickness of 2 nm, was successfully illustrated. The second sample was a Zr{sub 66.7}Ni{sub 33.3} metallic glass including a medium-range-order (MRO) structure, which was approximately considered to be a crystalline cluster with a diameter of 1.6 nm. In the experimental through-focal series, the lattice fringe of the MRO cluster was visible at limited focal conditions. Image simulations reproduced well the focal conditions and also indicated a structural condition for the visualization that the embedded cluster must be apart from the mid-plane of the matrix film. Similar to the case of the first sample, this result can be explained by the idea that the “effective focal planes” for the film and cluster are at different heights. This type of depth-resolution phase contrast imaging is possible only in aberration-corrected TEM and when the sample has a simple structure and is sufficiently thin for the kinematical scattering approximation. - Highlights: • Depth-resolution imaging by aberration-corrected TEM was demonstrated. • Thickness of a carbon film supporting gold nano-crystals was successfully estimated. • A crystalline nanocluster embedded in an amorphous matrix was successfully observed. • It was clarified that

  5. Helioseismic Constraints on the Depth Dependence of Large-Scale Solar Convection

    Science.gov (United States)

    Woodard, Martin F.

    2017-08-01

    A recent helioseismic statistical waveform analysis of subsurface flow based on a 720-day time series of SOHO/MDI Medium-l spherical-harmonic coefficients has been extended to cover a greater range of subphotospheric depths. The latest analysis provides estimates of flow-dependent oscillation-mode coupling-strength coefficients b(s,t;n,l) over the range l = 30 to 150 of mode degree (angular wavenumber) for solar p-modes in the approximate frequency range 2 to 4 mHz. The range of penetration depths of this mode set covers most of the solar convection zone. The most recent analysis measures spherical harmonic (s,t) components of the flow velocity for odd s in the angular wavenumber range 1 to 19 for t not much smaller than s at a given s. The odd-s b(s,t;n,l) coefficients are interpreted as averages over depth of the depth-dependent amplitude of one spherical-harmonic (s,t) component of the toroidal part of the flow velocity field. The depth-dependent weighting function defining the average velocity is the fractional kinetic energy density in radius of modes of the (n,l) multiplet. The b coefficients have been converted to estimates of root velocity power as a function of l0 = nu0*l/nu(n,l), which is a measure of mode penetration depth. (nu(n,l) is mode frequency and nu0 is a reference frequency equal to 3 mHz.) A comparison of the observational results with simple convection models will be presented.

  6. Unambiguous range-Doppler LADAR processing using 2 giga-sample-per-second noise waveforms

    International Nuclear Information System (INIS)

    Cole, Z.; Roos, P.A.; Berg, T.; Kaylor, B.; Merkel, K.D.; Babbitt, W.R.; Reibel, R.R.

    2007-01-01

    We demonstrate sub-nanosecond range and unambiguous sub-50-Hz Doppler resolved laser radar (LADAR) measurements using spectral holographic processing in rare-earth ion doped crystals. The demonstration utilizes pseudo-random-noise 2 giga-sample-per-second baseband waveforms modulated onto an optical carrier

  7. Unambiguous range-Doppler LADAR processing using 2 giga-sample-per-second noise waveforms

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Z. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States)]. E-mail: cole@s2corporation.com; Roos, P.A. [Spectrum Lab, Montana State University, P.O. Box 173510, Bozeman, MT 59717 (United States); Berg, T. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States); Kaylor, B. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States); Merkel, K.D. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States); Babbitt, W.R. [Spectrum Lab, Montana State University, P.O. Box 173510, Bozeman, MT 59717 (United States); Reibel, R.R. [S2 Corporation, 2310 University Way 4-1, Bozeman, MT 59715 (United States)

    2007-11-15

    We demonstrate sub-nanosecond range and unambiguous sub-50-Hz Doppler resolved laser radar (LADAR) measurements using spectral holographic processing in rare-earth ion doped crystals. The demonstration utilizes pseudo-random-noise 2 giga-sample-per-second baseband waveforms modulated onto an optical carrier.

  8. High-resolution delineation of chlorinated volatile organic compounds in a dipping, fractured mudstone: depth- and strata-dependent spatial variability from rock-core sampling

    Science.gov (United States)

    Goode, Daniel J.; Imbrigiotta, Thomas E.; Lacombe, Pierre J.

    2014-01-01

    Synthesis of rock-core sampling and chlorinated volatile organic compound (CVOC) analysis at five coreholes, with hydraulic and water-quality monitoring and a detailed hydrogeologic framework, was used to characterize the fine-scale distribution of CVOCs in dipping, fractured mudstones of the Lockatong Formation of Triassic age, of the Newark Basin in West Trenton, New Jersey. From these results, a refined conceptual model for more than 55 years of migration of CVOCs and depth- and strata-dependent rock-matrix contamination was developed. Industrial use of trichloroethene (TCE) at the former Naval Air Warfare Center (NAWC) from 1953 to 1995 resulted in dense non-aqueous phase liquid (DNAPL) TCE and dissolved TCE and related breakdown products, including other CVOCs, in underlying mudstones. Shallow highly weathered and fractured strata overlie unweathered, gently dipping, fractured strata that become progressively less fractured with depth. The unweathered lithology includes black highly fractured (fissile) carbon-rich strata, gray mildly fractured thinly layered (laminated) strata, and light-gray weakly fractured massive strata. CVOC concentrations in water samples pumped from the shallow weathered and highly fractured strata remain elevated near residual DNAPL TCE, but dilution by uncontaminated recharge, and other natural and engineered attenuation processes, have substantially reduced concentrations along flow paths removed from sources and residual DNAPL. CVOCs also were detected in most rock-core samples in source areas in shallow wells. In many locations, lower aqueous concentrations, compared to rock core concentrations, suggest that CVOCs are presently back-diffusing from the rock matrix. Below the weathered and highly fractured strata, and to depths of at least 50 meters (m), groundwater flow and contaminant transport is primarily in bedding-plane-oriented fractures in thin fissile high-carbon strata, and in fractured, laminated strata of the gently

  9. Spacecraft Trajectory Estimation Using a Sampled-Data Extended Kalman Filter with Range-Only Measurements

    National Research Council Canada - National Science Library

    Erwin, R. S; Bernstein, Dennis S

    2005-01-01

    .... In this paper we use a sampled-data extended Kalman Filter to estimate the trajectory or a target satellite when only range measurements are available from a constellation or orbiting spacecraft...

  10. Study of uranium mineralization in rock samples from marwat range bannu basin by fission track analysis technique

    International Nuclear Information System (INIS)

    Qureshi, A.Z.; Ullah, K.; Ullah, N.; Akram, M.

    2004-07-01

    The Geophysics Division, Atomic Energy Minerals Centre (AEMC), Lahore has planned a uranium exploration program in Marwat Range, Bannu Basin. In this connection 30 thin sections of rock samples, collected from four areas; namely, Darra Tang, Simukili, Karkanwal and Sheikhillah from Marwat Range, and one from Salt Range were provided to Nuclear Geology Group of Physics Research Division, PINSTECH for the study of nature and mechanism of uranium mineralization These studies are aimed to help in designing uranium exploration strategy by providing the loci of uranium sources in the Marwat and Salt Ranges. The samples have been studied using fission track analysis technique. (author)

  11. Depth-To-Basement Mapping Using Fractal Technique: Application ...

    African Journals Online (AJOL)

    ... and can thus be obtained at source level. Application to aeromagnetic data from the Chad basin north eastern Nigeria produced a basement relief which range from depths of 2.47 km to 5.40 km with an average of 3.92 +- 0.66 km. Keywords: Fractal, depth, basement, spectra, aeromagnetic. Nigerian Journal of Physics Vol ...

  12. Depth dependent stress revealed by aftershocks

    Science.gov (United States)

    Narteau, C.; Shebalin, P.

    2017-12-01

    Aftershocks occur in response to perturbations of the state of stress induced either by earthquakes or human activities. Along major strike-slip fault segments of the San Andreas fault system, the time-delay before the onset of the power-law aftershock decay rate (the c-value) varies by three orders of magnitude in the first twenty kilometers below the surface. Despite the influence of the lithostatic stress, there is no continuous change in c-value with respect to depth. Instead, two decay phases are separated by an abrupt increase at an intermediate depth range of 2 to 5 km. This transitional regime is the only one observed in fluid-injection-induced seismic areas. This provides strong evidence for the role of fluid and a porosity reduction mechanism at depth of few kilometers in active fault zones. Aftershock statistics can then be used to predict the evolution the differential shear stress with depth until the brittle-ductile transition is reached.

  13. Case depth in SAE 1020 steel using barkhausen noise

    Directory of Open Access Journals (Sweden)

    Alessandra Drehmer

    2013-01-01

    Full Text Available The most widely used thermochemical process for surface hardening of steels is case hardening. Using several different heat treatments, martensitic surface layers were formed on SAE 1020 steel into which carbon had been diffused. Case depths were measured by traditional destructive techniques. Barkhausen noise measurements were made and both the RMS Barkhausen pulse envelope and the fast Fourier transform (FFT were obtained from numerical calculation. The FFT amplitudes, functions of frequency, were associated with distance from the sample surface using the skin depth equation δ = 1/ (πfσµ½ , where f is the frequency of the electromagnetic wave, s is the electrical conductivity, and µ is the magnetic permeability. We define a normalized power index (NPI which can be used to estimate case depths. The NPI is discussed in relation to the sample microstructure and it is shown that the case depth is most easily determined when the magnetic properties of the surface layer and core are substantially different.

  14. Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range

    OpenAIRE

    Wan, Xiang; Wang, Wenqian; Liu, Jiming; Tong, Tiejun

    2014-01-01

    Background In systematic reviews and meta-analysis, researchers often pool the results of the sample mean and standard deviation from a set of similar clinical trials. A number of the trials, however, reported the study using the median, the minimum and maximum values, and/or the first and third quartiles. Hence, in order to combine results, one may have to estimate the sample mean and standard deviation for such trials. Methods In this paper, we propose to improve the existing literature in ...

  15. Sea Water Characterization at Ujung Kulon Coastal Depth as Raw Water Source for Desalination and Potential Energy

    Directory of Open Access Journals (Sweden)

    Mugisidi Dan

    2018-01-01

    Full Text Available Fresh water is basic need for life while the source is limited. Therefore, sea water is used as fresh water through desalination process. Sea water has different physical and chemical properties ranging from the surface to the seabed. The energy potential that can be obtained from the hydrostatic pressure also changes according to the depth. As part of the research of the utilization of sea water into fresh water, the aim of this study is to know the characteristics of sea water in the depth that can be utilized as source of fresh water. The sea water samples were taken at 11km from Ujung Kulon beach with depth of 0m, 20m, 40m, 60m, 80m, and 100m under the surface. The results showed that the physical properties at every depth were below the maximum allowable drinking water except for the amount of dissolved solids. Chemical characteristics at any depth above allowable level were fluoride, hardness (CaCo3, chloride, sodium, sulphate, and (KMnO4. In addition to the properties, pressure is one of the considerations in this study to determine the depth of sea water as sources for desalination. Pressure increased by 36.11% as the depth of the sea increased.

  16. Sea Water Characterization at Ujung Kulon Coastal Depth as Raw Water Source for Desalination and Potential Energy

    Science.gov (United States)

    Mugisidi, Dan; Heriyani, Okatrina

    2018-02-01

    Fresh water is basic need for life while the source is limited. Therefore, sea water is used as fresh water through desalination process. Sea water has different physical and chemical properties ranging from the surface to the seabed. The energy potential that can be obtained from the hydrostatic pressure also changes according to the depth. As part of the research of the utilization of sea water into fresh water, the aim of this study is to know the characteristics of sea water in the depth that can be utilized as source of fresh water. The sea water samples were taken at 11km from Ujung Kulon beach with depth of 0m, 20m, 40m, 60m, 80m, and 100m under the surface. The results showed that the physical properties at every depth were below the maximum allowable drinking water except for the amount of dissolved solids. Chemical characteristics at any depth above allowable level were fluoride, hardness (CaCo3), chloride, sodium, sulphate, and (KMnO4). In addition to the properties, pressure is one of the considerations in this study to determine the depth of sea water as sources for desalination. Pressure increased by 36.11% as the depth of the sea increased.

  17. Impact of sequencing depth on the characterization of the microbiome and resistome.

    Science.gov (United States)

    Zaheer, Rahat; Noyes, Noelle; Ortega Polo, Rodrigo; Cook, Shaun R; Marinier, Eric; Van Domselaar, Gary; Belk, Keith E; Morley, Paul S; McAllister, Tim A

    2018-04-12

    Developments in high-throughput next generation sequencing (NGS) technology have rapidly advanced the understanding of overall microbial ecology as well as occurrence and diversity of specific genes within diverse environments. In the present study, we compared the ability of varying sequencing depths to generate meaningful information about the taxonomic structure and prevalence of antimicrobial resistance genes (ARGs) in the bovine fecal microbial community. Metagenomic sequencing was conducted on eight composite fecal samples originating from four beef cattle feedlots. Metagenomic DNA was sequenced to various depths, D1, D0.5 and D0.25, with average sample read counts of 117, 59 and 26 million, respectively. A comparative analysis of the relative abundance of reads aligning to different phyla and antimicrobial classes indicated that the relative proportions of read assignments remained fairly constant regardless of depth. However, the number of reads being assigned to ARGs as well as to microbial taxa increased significantly with increasing depth. We found a depth of D0.5 was suitable to describe the microbiome and resistome of cattle fecal samples. This study helps define a balance between cost and required sequencing depth to acquire meaningful results.

  18. Chromatic confocal microscopy for multi-depth imaging of epithelial tissue

    Science.gov (United States)

    Olsovsky, Cory; Shelton, Ryan; Carrasco-Zevallos, Oscar; Applegate, Brian E.; Maitland, Kristen C.

    2013-01-01

    We present a novel chromatic confocal microscope capable of volumetric reflectance imaging of microstructure in non-transparent tissue. Our design takes advantage of the chromatic aberration of aspheric lenses that are otherwise well corrected. Strong chromatic aberration, generated by multiple aspheres, longitudinally disperses supercontinuum light onto the sample. The backscattered light detected with a spectrometer is therefore wavelength encoded and each spectrum corresponds to a line image. This approach obviates the need for traditional axial mechanical scanning techniques that are difficult to implement for endoscopy and susceptible to motion artifact. A wavelength range of 590-775 nm yielded a >150 µm imaging depth with ~3 µm axial resolution. The system was further demonstrated by capturing volumetric images of buccal mucosa. We believe these represent the first microstructural images in non-transparent biological tissue using chromatic confocal microscopy that exhibit long imaging depth while maintaining acceptable resolution for resolving cell morphology. Miniaturization of this optical system could bring enhanced speed and accuracy to endomicroscopic in vivo volumetric imaging of epithelial tissue. PMID:23667789

  19. Magma transport and olivine crystallization depths in Kīlauea’s East Rift Zone inferred from experimentally rehomogenized melt inclusions

    Science.gov (United States)

    Tuohy, Robin M; Wallace, Paul J.; Loewen, Matthew W; Swanson, Don; Kent, Adam J R

    2016-01-01

    Concentrations of H2O and CO2 in olivine-hosted melt inclusions can be used to estimate crystallization depths for the olivine host. However, the original dissolved CO2concentration of melt inclusions at the time of trapping can be difficult to measure directly because in many cases substantial CO2 is transferred to shrinkage bubbles that form during post-entrapment cooling and crystallization. To investigate this problem, we heated olivine from the 1959 Kīlauea Iki and 1960 Kapoho (Hawai‘i) eruptions in a 1-atm furnace to temperatures above the melt inclusion trapping temperature to redissolve the CO2 in shrinkage bubbles. The measured CO2 concentrations of the experimentally rehomogenized inclusions (⩽590 ppm for Kīlauea Iki [n=10]; ⩽880 ppm for Kapoho, with one inclusion at 1863 ppm [n=38]) overlap with values for naturally quenched inclusions from the same samples, but experimentally rehomogenized inclusions have higher within-sample median CO2 values than naturally quenched inclusions, indicating at least partial dissolution of CO2 from the vapor bubble during heating. Comparison of our data with predictions from modeling of vapor bubble formation and published Raman data on the density of CO2 in the vapor bubbles suggests that 55-85% of the dissolved CO2 in the melt inclusions at the time of trapping was lost to post-entrapment shrinkage bubbles. Our results combined with the Raman data demonstrate that olivine from the early part of the Kīlauea Iki eruption crystallized at <6 km depth, with the majority of olivine in the 1-3 km depth range. These depths are consistent with the interpretation that the Kīlauea Iki magma was supplied from Kīlauea’s summit magma reservoir (∼2-5 km depth). In contrast, olivine from Kapoho, which was the rift zone extension of the Kīlauea Iki eruption, crystallized over a much wider range of depths (∼1-16 km). The wider depth range requires magma transport during the Kapoho eruption from deep beneath the

  20. FINANCIAL DEPTH AND FINANCIAL ACCESS IN INDONESIA

    OpenAIRE

    Sigit Setiawan

    2015-01-01

    This study is intended to analyze the current levels of financial depth and financial access in Indonesia and to analyze the factors affecting them. The analysis method used was a combination of descriptive quantitative, benchmarking, and literature reviews. The conclusion is that the financial depth in Indonesia has not shown a satisfactory level since it was the lowest, or the second lowest ranked country among the sampled countries. Meanwhile, the financial access in Indonesia is relativel...

  1. Shaded-Mask Filtering for Extended Depth-of-Field Microscopy

    OpenAIRE

    Escobar García, Isabel María; Saavedra Tortosa, Genaro; Martínez Corral, Manuel; Calatayud, Arnau; Doblas Expósito, Ana Isabel

    2013-01-01

    This paper proposes a new spatial filtering approach for increasing the depth-of-field (DOF) of imaging systems, which is very useful for obtaining sharp images for a wide range of axial positions of the object. Many different techniques have been reported to increase the depth of field. However the main advantage in our method is its simplicity, since we propose the use of purely absorbing beam-shaping elements, which allows a high focal depth with a minimum modification of the optical archi...

  2. Lead pollution of soil and groundwater in clay-pigeon shooting ranges

    International Nuclear Information System (INIS)

    Hahn, R.

    1990-01-01

    Within the framework of the exemplary investigation of soil and groundwater pollution with lead on clay-pigeon shooting ranges, three facilities were sampled. The analyses for depth distribution in the main area of the ammunition deposition showed that the dissolved lead amounts are as a rule smaller than the limiting value of the Sewage Sludge Regulation (100 mg/kg). In two groundwater samples, no lead could be found. Considerable amounts of small lead balls are found on the soil surface, but only a very small part appears to be washed out and adsorbed by the soil matrix. (orig.) [de

  3. Cuff depth and continuous chest auscultation method for determination of tracheal tube insertion depth in nasal intubation: observational study.

    Science.gov (United States)

    Ouchi, Kentaro; Sugiyama, Kazuna

    2016-04-01

    Incorrect endobronchial placement of the tracheal tube can lead to serious complications. Hence, it is necessary to determine the accuracy of tracheal tube positioning. Markers are included on tracheal tubes, in the process of their manufacture, as indicators of approximate intubation depth. In addition, continuous chest auscultation has been used for determining the proper position of the tube. We examined insertion depth using the cuff depth and continuous chest auscultation method (CC method), compared with insertion depth determined by the marker method, to assess the accuracy of these methods. After induction of anesthesia, tracheal intubation was performed in each patient. In the CC method, the depth of tube insertion was measured when the cuff had passed through the glottis, and again when breath sounds changed in quality; the depth of tube insertion was determined from these values. In the marker method, the depth of tube insertion was measured and determined when the marker of the tube had reached the glottis, using insertion depth according to the marker as an index. Insertion depth by the marker method was 26.6 ± 1.2 cm and by the CC method was 28.0 ± 1.2 cm (P < 0.0001). The CC method indicated a significantly greater depth than the marker method. This study determined the safe range of tracheal tube placement. Tube positions determined by the CC method were about 1 cm deeper than those determined by the marker. This information is important to prevent accidental one-lung ventilation and accidental extubation. UMIN No. UMIN000011375.

  4. Wavefield Extrapolation in Pseudo-depth Domain

    KAUST Repository

    Ma, Xuxin

    2011-12-11

    Wave-equation based seismic migration and inversion tools are widely used by the energy industry to explore hydrocarbon and mineral resources. By design, most of these techniques simulate wave propagation in a space domain with the vertical axis being depth measured from the surface. Vertical depth is popular because it is a straightforward mapping of the subsurface space. It is, however, not computationally cost-effective because the wavelength changes with local elastic wave velocity, which in general increases with depth in the Earth. As a result, the sampling per wavelength also increases with depth. To avoid spatial aliasing in deep fast media, the seismic wave is oversampled in shallow slow media and therefore increase the total computation cost. This issue is effectively tackled by using the vertical time axis instead of vertical depth. This is because in a vertical time representation, the "wavelength" is essentially time period for vertical rays. This thesis extends the vertical time axis to the pseudo-depth axis, which features distance unit while preserving the properties of the vertical time representation. To explore the potentials of doing wave-equation based imaging in the pseudo-depth domain, a Partial Differential Equation (PDE) is derived to describe acoustic wave in this new domain. This new PDE is inherently anisotropic because the use of a constant vertical velocity to convert between depth and vertical time. Such anisotropy results in lower reflection coefficients compared with conventional space domain modeling results. This feature is helpful to suppress the low wavenumber artifacts in reverse-time migration images, which are caused by the widely used cross-correlation imaging condition. This thesis illustrates modeling acoustic waves in both conventional space domain and pseudo-depth domain. The numerical tool used to model acoustic waves is built based on the lowrank approximation of Fourier integral operators. To investigate the potential

  5. Pursuing the Depths of Knowledge

    Science.gov (United States)

    Boyles, Nancy

    2016-01-01

    Today's state literacy standards and assessments demand deeper levels of knowledge from students. But many teachers ask, "What does depth of knowledge look like on these new, more rigorous assessments? How do we prepare students for this kind of thinking?" In this article, Nancy Boyles uses a sampling of questions from the PARCC and SBAC…

  6. Porosity-depth trends of carbonate deposits along the northwest shelf of Australia (IODP Expedition 356)

    Science.gov (United States)

    Lee, Eun Young; Kominz, Michelle; Reuning, Lars; Takayanagi, Hideko; Knierzinger, Wolfgang; Wagreich, Michael; Expedition 356 shipboard scientists, IODP

    2017-04-01

    The northwest shelf (NWS) of Australia extends from northern tropical to southern temperate latitudes situated offshore from the low-moderate-relief and semi-arid Australian continent. The shelf environment is dominated throughout by carbonate sedimentation with warm-water and tropical carbonate deposits, connected to the long-term northward drift of Australia bringing the NWS into tropical latitudes. IODP expedition 356 cored seven sites (U1458-U1464) covering a latitudinal range of 29°S-18°S off the NWS. This study focuses on porosity-depth trends of the Miocene - Pleistocene carbonate sediment on the NWS. The NWS is an ideal area to study regional (and furthermore general) carbonate porosity-depth relationships, because it contains a nearly continuous sequence of carbonate sediment ranging in depth from the surface to about 1,100m and in age from Pleistocene to Miocene. Porosity-depth trends of sedimentary rocks are generally controlled by a variety of factors which govern the rates of porosity loss due to mechanical compaction and of porosity loss (or gain) due to chemical processes during diagenesis. This study derives porosity data from Moisture and Density (MAD) technique conducted during IODP Expedition 356. MAD samples were collected from packstone (44%), wackestone (27%), mudstone (15%) and grainstone (7%), with the rest from floatstone, rudstone, dolostone, sandstone and other subordinate lithologies. To understand porosity-depth trends, the porosity data are arranged both exponentially and linearly, and correlated with age models and lithologic descriptions provided by IODP shipboard scientists. Porosity(%)-depth(m) trends of all the porosity data are Porosity=52e-0.0008/Depth (exponential) and Porosity=-0.03Depth+52 (linear). Porosities near surface and in the deepest parts of each well are least well represented by these trend lines. Porosity values of Pleistocene sediment are generally higher than those of Miocene - Pliocene sediment. The initial

  7. Depth profiling of {sup 14} N and {sup 20} Ne implantation into iron and steel using(p, gamma) reactions. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Wriekat, A; Haj-Abdellah, M [Physics Department, University of Jordan, Amman (Jordan)

    1996-03-01

    Depth profiles of {sup 14} N and {sup 20} Ne ions at 800 KeV implanted into iron and by steel samples have been measured by means of the proton induced {gamma}- ray emission (Pige) technique. The range, R, and range straggling, {Delta}R for these profiles were obtained and compared with theoretical calculations. The experimental results did show that pure iron retains more N and Ne than steel. 2 figs., 1 tab.

  8. FINANCIAL DEPTH AND FINANCIAL ACCESS IN INDONESIA

    OpenAIRE

    Sigit Setiawan

    2015-01-01

    This study is intended to analyse the current levels of financial depth and financial access in Indonesia and to analyse the factors affecting them. The analysis method used was a combination of descriptive quantitative, benchmarking, and literature reviews. The conclusion is that the financial depth in Indonesia has not shown a satisfactory level since it was the lowest, or the second lowest ranked country among the sampled countries. Meanwhile, the financial access in Indonesia is relativel...

  9. Financial Depth and Financial Access in Indonesia

    OpenAIRE

    Setiawan, Sigit

    2015-01-01

    This study is intended to analyse the current levels of financial depth and financial access in Indonesia and to analyse the factors affecting them. The analysis method used was a combination of descriptive quantitative, benchmarking, and literature reviews. The conclusion is that the financial depth in Indonesia has not shown a satisfactory level since it was the lowest, or the second lowest ranked country among the sampled countries. Meanwhile, the financial access in Indonesia is relativel...

  10. Scales of snow depth variability in high elevation rangeland sagebrush

    Science.gov (United States)

    Tedesche, Molly E.; Fassnacht, Steven R.; Meiman, Paul J.

    2017-09-01

    In high elevation semi-arid rangelands, sagebrush and other shrubs can affect transport and deposition of wind-blown snow, enabling the formation of snowdrifts. Datasets from three field experiments were used to investigate the scales of spatial variability of snow depth around big mountain sagebrush ( Artemisia tridentata Nutt.) at a high elevation plateau rangeland in North Park, Colorado, during the winters of 2002, 2003, and 2008. Data were collected at multiple resolutions (0.05 to 25 m) and extents (2 to 1000 m). Finer scale data were collected specifically for this study to examine the correlation between snow depth, sagebrush microtopography, the ground surface, and the snow surface, as well as the temporal consistency of snow depth patterns. Variograms were used to identify the spatial structure and the Moran's I statistic was used to determine the spatial correlation. Results show some temporal consistency in snow depth at several scales. Plot scale snow depth variability is partly a function of the nature of individual shrubs, as there is some correlation between the spatial structure of snow depth and sagebrush, as well as between the ground and snow depth. The optimal sampling resolution appears to be 25-cm, but over a large area, this would require a multitude of samples, and thus a random stratified approach is recommended with a fine measurement resolution of 5-cm.

  11. FINANCIAL DEPTH AND FINANCIAL ACCESS IN INDONESIA

    Directory of Open Access Journals (Sweden)

    Sigit Setiawan

    2015-05-01

    Full Text Available This study is intended to analyze the current levels of financial depth and financial access in Indonesia and to analyze the factors affecting them. The analysis method used was a combination of descriptive quantitative, benchmarking, and literature reviews. The conclusion is that the financial depth in Indonesia has not shown a satisfactory level since it was the lowest, or the second lowest ranked country among the sampled countries. Meanwhile, the financial access in Indonesia is relatively better than its financial depth, especially for financial markets, in which Indonesia ranks in the lower average group. From literature reviews, it can be inferred that the main factor driving the poor financial depth in Indonesia is non-competitiveness of the institutions; whereas the driving force of poor financial access in Indonesia are geographical constraints, poverty, a high income gap, and a less than effective national financial development policy.

  12. Quantification of change in vocal fold tissue stiffness relative to depth of artificial damage.

    Science.gov (United States)

    Rohlfs, Anna-Katharina; Schmolke, Sebastian; Clauditz, Till; Hess, Markus; Müller, Frank; Püschel, Klaus; Roemer, Frank W; Schumacher, Udo; Goodyer, Eric

    2017-10-01

    To quantify changes in the biomechanical properties of human excised vocal folds with defined artificial damage. The linear skin rheometer (LSR) was used to obtain a series of rheological measurements of shear modulus from the surface of 30 human cadaver vocal folds. The tissue samples were initially measured in a native condition and then following varying intensities of thermal damage. Histological examination of each vocal fold was used to determine the depth of artificial alteration. The measured changes in stiffness were correlated with the depth of cell damage. For vocal folds in a pre-damage state the shear modulus values ranged from 537 Pa to 1,651 Pa (female) and from 583 Pa to 1,193 Pa (male). With increasing depth of damage from the intermediate layer of the lamina propria (LP), tissue stiffness increased consistently (compared with native values) following application of thermal damage to the vocal folds. The measurement showed an increase of tissue stiffness when the depth of tissue damage was extending from the intermediate LP layer downwards. Changes in the elastic characteristics of human vocal fold tissue following damage at defined depths were demonstrated in an in vitro experiment. In future, reproducible in vivo measurements of elastic vocal fold tissue alterations may enable phonosurgeons to infer the extent of subepithelial damage from changes in surface elasticity.

  13. Refractive index depth profile in PMMA due to proton irradiation

    International Nuclear Information System (INIS)

    Szilasi, S.Z.; Rajta, I.; Budai, J.; Toth, Z.; Petrik, P.; Baradacs, E.

    2006-01-01

    for the determination of optical properties. All irradiations in this work have been performed on the 5 MV Van de Graaff accelerator of the Institute. The samples were Roehm GS233 type PMMA. The main irradiation parameters were: ∼2 MeV proton energy and 100 nC/mm 2 fluence, because these are typical values for P-beam Writing on PMMA. In this experiment, what we called 'PMMA foil method', the proton energy was varied in the range 1.7-2.1 MeV. A 50 μm thick PMMA foil was attached to the top of bulk PMMA samples in order to decelerate the protons. Depending on the used energy, different energy delivery levels were reached at the bulk PMMA surface (Fig. 1.). The ellipsometric analyses were performed on a Woollam M2000F rotating compensator ellipsometer in Szeged. The measurements were carried out at 476 different wavelengths in the range of 245-1000 nm. The angle of incidence (50 deg, 52 deg, 54 deg, 56 deg, 58 deg) was chosen to be near the Brewster-angle of PMMA. From the ellipsometric measurements the refractive index and the extinction coefficient as a function of the wavelength can be determined by a special modeling procedure. For full details of this work see the complete paper [2]. Here we present one particular visualisation of the results. In the investigated proton energy range the Bragg curves behave similarly, the protons slow down by many collisions of small energy transfer to the electrons of the sample. We calculated the energy loss ΔE/Δx for the 1.7-2.1 MeV protons after passing through 50 μm of PMMA, then we found the same energy loss value on the 2 MeV protons Bragg curve in bulk PMMA. Having the refractive index values at the 1.7-2.1 MeV protons at 50 μm depth, we plotted the refractive index values caused by 2 MeV protons at the calculated depths. Fig. 2. shows these results. In addition we also plotted the Bragg curve of 2 MeV protons on the same depth scale. Since the agreement between the measured refractive indices and the Bragg curve looks

  14. Using a Cell Phone to Investigate the Skin Depth Effect in Salt Water

    Science.gov (United States)

    Rayner, John

    2017-01-01

    This paper describes an experimental investigation of the skin depth effect for electromagnetic waves in salt water using a cell phone that is immersed to a critical depth where it no longer responds when called. We show that this critical depth is directly proportional to the theoretical skin depth for a range of salt concentrations.

  15. Scanning Auger microscopy for high lateral and depth elemental sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, E., E-mail: eugenie.martinez@cea.fr [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Yadav, P. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Bouttemy, M. [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France); Renault, O.; Borowik, Ł.; Bertin, F. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Etcheberry, A. [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France); Chabli, A. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France)

    2013-12-15

    Highlights: •SAM performances and limitations are illustrated on real practical cases such as the analysis of nanowires and nanodots. •High spatial elemental resolution is shown with the analysis of reference semiconducting Al{sub 0.7}Ga{sub 0.3}As/GaAs multilayers. •High in-depth elemental resolution is also illustrated. Auger depth profiling with low energy ion beams allows revealing ultra-thin layers (∼1 nm). •Analysis of cross-sectional samples is another effective approach to obtain in-depth elemental information. -- Abstract: Scanning Auger microscopy is currently gaining interest for investigating nanostructures or thin multilayers stacks developed for nanotechnologies. New generation Auger nanoprobes combine high lateral (∼10 nm), energy (0.1%) and depth (∼2 nm) resolutions thus offering the possibility to analyze the elemental composition as well as the chemical state, at the nanometre scale. We report here on the performances and limitations on practical examples from nanotechnology research. The spatial elemental sensitivity is illustrated with the analysis of Al{sub 0.7}Ga{sub 0.3}As/GaAs heterostructures, Si nanowires and SiC nanodots. Regarding the elemental in-depth composition, two effective approaches are presented: low energy depth profiling to reveal ultra-thin layers (∼1 nm) and analysis of cross-sectional samples.

  16. Automated Sampling and Extraction of Krypton from Small Air Samples for Kr-85 Measurement Using Atom Trap Trace Analysis

    International Nuclear Information System (INIS)

    Hebel, S.; Hands, J.; Goering, F.; Kirchner, G.; Purtschert, R.

    2015-01-01

    Atom-Trap-Trace-Analysis (ATTA) provides the capability of measuring the Krypton-85 concentration in microlitre amounts of krypton extracted from air samples of about 1 litre. This sample size is sufficiently small to allow for a range of applications, including on-site spot sampling and continuous sampling over periods of several hours. All samples can be easily handled and transported to an off-site laboratory for ATTA measurement, or stored and analyzed on demand. Bayesian sampling methodologies can be applied by blending samples for bulk measurement and performing in-depth analysis as required. Prerequisite for measurement is the extraction of a pure krypton fraction from the sample. This paper introduces an extraction unit able to isolate the krypton in small ambient air samples with high speed, high efficiency and in a fully automated manner using a combination of cryogenic distillation and gas chromatography. Air samples are collected using an automated smart sampler developed in-house to achieve a constant sampling rate over adjustable time periods ranging from 5 minutes to 3 hours per sample. The smart sampler can be deployed in the field and operate on battery for one week to take up to 60 air samples. This high flexibility of sampling and the fast, robust sample preparation are a valuable tool for research and the application of Kr-85 measurements to novel Safeguards procedures. (author)

  17. Generalist dinoflagellate endosymbionts and host genotype diversity detected from mesophotic (67-100 m depths coral Leptoseris

    Directory of Open Access Journals (Sweden)

    Kahng Samuel E

    2009-09-01

    Full Text Available Abstract Background Mesophotic corals (light-dependent corals in the deepest half of the photic zone at depths of 30 - 150 m provide a unique opportunity to study the limits of the interactions between corals and endosymbiotic dinoflagellates in the genus Symbiodinium. We sampled Leptoseris spp. in Hawaii via manned submersibles across a depth range of 67 - 100 m. Both the host and Symbiodinium communities were genotyped, using a non-coding region of the mitochondrial ND5 intron (NAD5 and the nuclear ribosomal internal transcribed spacer region 2 (ITS2, respectively. Results Coral colonies harbored endosymbiotic communities dominated by previously identified shallow water Symbiodinium ITS2 types (C1_ AF333515, C1c_ AY239364, C27_ AY239379, and C1b_ AY239363 and exhibited genetic variability at mitochondrial NAD5. Conclusion This is one of the first studies to examine genetic diversity in corals and their endosymbiotic dinoflagellates sampled at the limits of the depth and light gradients for hermatypic corals. The results reveal that these corals associate with generalist endosymbiont types commonly found in shallow water corals and implies that the composition of the Symbiodinium community (based on ITS2 alone is not responsible for the dominance and broad depth distribution of Leptoseris spp. The level of genetic diversity detected in the coral NAD5 suggests that there is undescribed taxonomic diversity in the genus Leptoseris from Hawaii.

  18. Chemical changes in PMMA as a function of depth due to proton beam irradiation

    International Nuclear Information System (INIS)

    Szilasi, S.Z.; Huszank, R.; Szikra, D.; Vaczi, T.; Rajta, I.; Nagy, I.

    2011-01-01

    Highlights: → Chemical changes were investigated as a function of depth in proton irradiated PMMA → The depth profile of numerous functional groups was determined along the depth → The degree of chemical modification strongly depends on the LET of protons → At low-fluences the zone of maximal modification is restricted to the Bragg peak → At higher fluences the zone of max. modification extends towards the sample surface. - Abstract: In this work we determined depth profiles of the chemical change in PMMA irradiated with 2 MeV protons by infrared spectroscopic and micro-Raman measurements. The measurements were carried out on 10 μm thin stacked foil samples using an infrared spectrometer in universal attenuated total reflectance (UATR) and transmission modes; while the thick samples were analyzed with a confocal micro-Raman spectrometer. The depth profiles of the changes formed due to the various delivered fluences were compared to each other. The measurements show the strong dependence of the degree of modification on the energy transfer from the decelerating protons. Depth profiles reveal that at the fluences applied in this work the entire irradiated volume suffered some chemical modifications. In case of low-fluence samples the zone of maximal modification is restricted only to the Bragg peak, but with increasing fluences the region of maximal modification extends towards the sample surface.

  19. Depth sectioning using electron energy loss spectroscopy

    International Nuclear Information System (INIS)

    D'Alfonso, A J; Findlay, S D; Allen, L J; Cosgriff, E C; Kirkland, A I; Nellist, P D; Oxley, M P

    2008-01-01

    The continued development of electron probe aberration correctors for scanning transmission electron microscopy has enabled finer electron probes, allowing atomic resolution column-by-column electron energy loss spectroscopy. Finer electron probes have also led to a decrease in the probe depth of focus, facilitating optical slicing or depth sectioning of samples. The inclusion of post specimen aberration corrected image forming lenses allows for scanning confocal electron microscopy with further improved depth resolution and selectivity. We show that in both scanning transmission electron microscopy and scanning confocal electron microscopy geometries, by performing a three dimensional raster scan through a specimen and detecting electrons scattered with a characteristic energy loss, it will be possible to determine the location of isolated impurities embedded within the bulk.

  20. Measurements of seasonal frost depth by frost tube in Japan

    Science.gov (United States)

    Harada, K.; Yoshikawa, K.; Iwahana, G.; Stanilovskaya, J. V.; Sawada, Y.; Sone, T.

    2017-12-01

    Since 2011 winter season, frost depths have been measured as an outreach program in Hokkaido, northern part of Japan, where seasonal ground freezing occurs in winter. Frost depths were measured in elementary, junior high and high schools in order to emphasis their interest for earth sciences. At schools, using simple frost tube, measurements were conducted directly once a week by students or teacher during ground freezing under no snow-removal condition. A lecture was made in class and a frost tube was set at schoolyard, as the same tube and protocol as UAF's Permafrost Outreach Program, using clear tube with blue-colored water. In 2011 winter season, we started measurements at three schools, and the number of school extended to 32 in 2016 season, 26 elementary schools, 5 junior high schools and one high school. We visited schools in summer time or just before frost season to talk about the method of measurement, and measurements by students started just after ground freezing. After the end of frozen period, we visited schools again to explain results of each school or another schools in Japan, Alaska, Canada or Russia. The measured frost depths in Hokkaido ranged widely, from only a few centimeter to more than 50 cm. However, some schools had no frost depth due to heavy snow. We confirmed that the frost depth strongly depends on air temperature and snow depth. The lecture was made to student why the frost depth ranged widely, and the effect of snow was explained by using the example of igloo. In order to validate the effect of snow and to compare frost depths, we tried to measure frost depths under snow-removal and no snow-removal conditions at the same elementary school. At the end of December, depths had no significant difference between these conditions, and the difference went to 14 cm after one month, with about 30 cm of snow depth. After these measurements and lectures, students noticed snow has a role as insulator and affects the frost depth.

  1. On Range of Skill

    DEFF Research Database (Denmark)

    Hansen, Thomas Dueholm; Miltersen, Peter Bro; Sørensen, Troels Bjerre

    2008-01-01

    size (and doubly exponential in its depth). We also provide techniques that yield concrete bounds for unbalanced game trees and apply these to estimate the Range of Skill of Tic-Tac-Toe and Heads-Up Limit Texas Hold'em Poker. In particular, we show that the Range of Skill of Tic-Tac-Toe is more than...

  2. Sampling and instrumentation requirements for long-range D and D activities at INEL

    International Nuclear Information System (INIS)

    Ahlquist, A.J.

    1985-01-01

    Assistance was requested to help determine sampling and instrumentation requirements for the long-range decontamination and decommissioning activities at the Idaho National Engineering Laboratory. Through a combination of literature review, visits to other DOE contractors, and a determination of the needs for the INEL program, a draft report has been prepared that is now under review. The final report should be completed in FY 84

  3. A technique for determining the depth distribution of cavities in He+-irradiated nickel

    International Nuclear Information System (INIS)

    Fenske, G.; Das, S.K.; Kaminsky, M.

    1979-01-01

    The authors describe a technique for examining the depth distribution of the damage (i.e., dislocations, bubbles and voids) in 4 He + ion-irradiated nickel. One existing technique is to section the sample parallel to the direction of the incident beam and prepare thin foils suitable for TEM. This technique has been used only in a few instances because of the difficulty in sample preparation, but it has the advantage that the entire depth distribution of damage can be obtained from a single sample. The technique described by the present authors is a modification of this type of technique and allows one to observe the depth distribution of bubbles and of damage in very near surface regions (<0.2μm) with excellent depth resolution and a small (approximately 50 A) uncertainty in locating the irradiated surface. (Auth.)

  4. Wavefield extrapolation in pseudo-depth domain

    KAUST Repository

    Ma, Xuxin; Alkhalifah, Tariq Ali

    2012-01-01

    Extrapolating seismic waves in Cartesian coordinate is prone to uneven spatial sampling, because the seismic wavelength tends to grow with depth, as velocity increase. We transform the vertical depth axis to a pseudo one using a velocity weighted mapping, which can effectively mitigate this wavelength variation. We derive acoustic wave equations in this new domain based on the direct transformation of the Laplacian derivatives, which admits solutions that are more accurate and stable than those derived from the kinematic transformation. The anisotropic versions of these equations allow us to isolate the vertical velocity influence and reduce its impact on modeling and imaging. The major benefit of extrapolating wavefields in pseudo-depth space is its near uniform wavelength as opposed to the normally dramatic change of wavelength with the conventional approach. Time wavefield extrapolation on a complex velocity shows some of the features of this approach.

  5. Deuterium Depth Profile in Neutron-Irradiated Tungsten Exposed to Plasma

    International Nuclear Information System (INIS)

    Shimada, Masashi; Cao, G.; Hatano, Y.; Oda, T.; Oya, Y.; Hara, M.; Calderoni, P.

    2011-01-01

    The effect of radiation damage has been mainly simulated using high-energy ion bombardment. The ions, however, are limited in range to only a few microns into the surface. Hence, some uncertainty remains about the increase of trapping at radiation damage produced by 14 MeV fusion neutrons, which penetrate much farther into the bulk material. With the Japan-US joint research project: Tritium, Irradiations, and Thermofluids for America and Nippon (TITAN), the tungsten samples (99.99 % pure from A.L.M.T., 6mm in diameter, 0.2mm in thickness) were irradiated to high flux neutrons at 50 C and to 0.025 dpa in the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL). Subsequently, the neutron-irradiated tungsten samples were exposed to a high-flux deuterium plasma (ion flux: 1021-1022 m-2s-1, ion fluence: 1025-1026 m-2) in the Tritium Plasma Experiment (TPE) at the Idaho National Laboratory (INL). First results of deuterium retention in neutron-irradiated tungsten exposed in TPE have been reported previously. This paper presents the latest results in our on-going work of deuterium depth profiling in neutron-irradiated tungsten via nuclear reaction analysis. The experimental data is compared with the result from non neutron-irradiated tungsten, and is analyzed with the Tritium Migration Analysis Program (TMAP) to elucidate the hydrogen isotope behavior such as retention and depth distribution in neutron-irradiated and non neutron-irradiated tungsten.

  6. Note: long range and accurate measurement of deep trench microstructures by a specialized scanning tunneling microscope.

    Science.gov (United States)

    Ju, Bing-Feng; Chen, Yuan-Liu; Zhang, Wei; Zhu, Wule; Jin, Chao; Fang, F Z

    2012-05-01

    A compact but practical scanning tunneling microscope (STM) with high aspect ratio and high depth capability has been specially developed. Long range scanning mechanism with tilt-adjustment stage is adopted for the purpose of adjusting the probe-sample relative angle to compensate the non-parallel effects. A periodical trench microstructure with a pitch of 10 μm has been successfully imaged with a long scanning range up to 2.0 mm. More innovatively, a deep trench with depth and step height of 23.0 μm has also been successfully measured, and slope angle of the sidewall can approximately achieve 67°. The probe can continuously climb the high step and exploring the trench bottom without tip crashing. The new STM could perform long range measurement for the deep trench and high step surfaces without image distortion. It enables accurate measurement and quality control of periodical trench microstructures.

  7. Mapping snow depth in complex alpine terrain with close range aerial imagery - estimating the spatial uncertainties of repeat autonomous aerial surveys over an active rock glacier

    Science.gov (United States)

    Goetz, Jason; Marcer, Marco; Bodin, Xavier; Brenning, Alexander

    2017-04-01

    Snow depth mapping in open areas using close range aerial imagery is just one of the many cases where developments in structure-from-motion and multi-view-stereo (SfM-MVS) 3D reconstruction techniques have been applied for geosciences - and with good reason. Our ability to increase the spatial resolution and frequency of observations may allow us to improve our understanding of how snow depth distribution varies through space and time. However, to ensure accurate snow depth observations from close range sensing we must adequately characterize the uncertainty related to our measurement techniques. In this study, we explore the spatial uncertainties of snow elevation models for estimation of snow depth in a complex alpine terrain from close range aerial imagery. We accomplish this by conducting repeat autonomous aerial surveys over a snow-covered active-rock glacier located in the French Alps. The imagery obtained from each flight of an unmanned aerial vehicle (UAV) is used to create an individual digital elevation model (DEM) of the snow surface. As result, we obtain multiple DEMs of the snow surface for the same site. These DEMs are obtained from processing the imagery with the photogrammetry software Agisoft Photoscan. The elevation models are also georeferenced within Photoscan using the geotagged imagery from an onboard GNSS in combination with ground targets placed around the rock glacier, which have been surveyed with highly accurate RTK-GNSS equipment. The random error associated with multi-temporal DEMs of the snow surface is estimated from the repeat aerial survey data. The multiple flights are designed to follow the same flight path and altitude above the ground to simulate the optimal conditions of repeat survey of the site, and thus try to estimate the maximum precision associated with our snow-elevation measurement technique. The bias of the DEMs is assessed with RTK-GNSS survey observations of the snow surface elevation of the area on and surrounding

  8. Measurement of peak impact loads differ between accelerometers - Effects of system operating range and sampling rate.

    Science.gov (United States)

    Ziebart, Christina; Giangregorio, Lora M; Gibbs, Jenna C; Levine, Iris C; Tung, James; Laing, Andrew C

    2017-06-14

    A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  9. Yeasts from the sediment samples of the EEZ along the southwest coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    Prabhakaran, N.; Gupta, R.

    Fiftyeight yeast isolates were obtained from the benthic sediment samples of 19 stations during R.V. Gaveshani Cruise No. 187 of the Exclusive Economic Zone along the southwest coast of India. The depths ranged from 20 to 1,055 m. Asporogenous yeast...

  10. Geothermal properties of Swiss Molasse Basin (depth range 0-500 m) - 2006 upgrade of the thermal conductivity, heat capacity, rock density and porosity data base

    International Nuclear Information System (INIS)

    Leu, W.; Megel, T.; Schaerli, U.

    2006-01-01

    The main aim of this project is the preparation of a specific data base of geothermal properties for typical rocks of the Swiss Molasse Basin (depth interval 0-500 m). The project includes the development of a new laboratory tool for efficient heat capacity measurements on rock samples, numerous new measurements of geothermal rock properties in the laboratory and calculation of such data from geophysical borehole logs. In the geographical area under review, 282 rock samples, mainly from deep boreholes, were analyzed with the successfully calibrated new heat capacity device and conventional thermal conductivity measuring techniques (cuttings and cores). Based on sonic and density log data from exploration wells, 374 additional data points were generated. This new data base characterizes in detail the six main lithological rock types in the three Molasse groups OSM, OMM and USM within the Swiss Plateau Molasse. The statistical evaluation of all data illustrates the regional variation of the petrophysical and geothermal parameters. For most data groups bulk rock density and thermal conductivity increase, whereas heat capacity decreases in the direction towards the Alpine front. Thermal conductivity shows a distinct increase with depth. Based on this new information and with the aid of the evaluation software tool SwEWS, the costs of planned geothermal installations can be optimized thanks to more precise heat extraction simulations with existing software packages like COSOND, TRNSYS, EWS or WPcalc. (author)

  11. New formula for calculation of cobalt-60 percent depth dose

    International Nuclear Information System (INIS)

    Tahmasebi Birgani, M. J.; Ghorbani, M.

    2005-01-01

    On the basis of percent depth dose calculation, the application of - dosimetry in radiotherapy has an important role to play in reducing the chance of tumor recurrence. The aim of this study is to introduce a new formula for calculating the central axis percent depth doses of Cobalt-60 beam. Materials and Methods: In the present study, based on the British Journal of Radiology table, nine new formulas are developed and evaluated for depths of 0.5 - 30 cm and fields of (4*4) - (45*45) cm 2 . To evaluate the agreement between the formulas and the table, the average of the absolute differences between the values was used and the formula with the least average was selected as the best fitted formula. The Microsoft Excel 2000 and the Data fit 8.0 soft wares were used to perform the calculations. Results: The results of this study indicated that one amongst the nine formulas gave a better agreement with the percent depth doses listed in the table of British Journal of Radiology . The new formula has two parts in terms of log (A/P). The first part as a linear function with the depth in the range of 0.5 to 5 cm and the other one as a second order polynomial with the depth in the range of 6 to 30 cm. The average of - the differences between the tabulated and the calculated data using the formula (Δ) is equal to 0.3 152. Discussion and Conclusion: Therefore, the calculated percent depth dose data based on this formula has a better agreement with the published data for Cobalt-60 source. This formula could be used to calculate the percent depth dose for the depths and the field sizes not listed in the British Journal of Radiology table

  12. Feasibility of proton-activated implantable markers for proton range verification using PET

    Science.gov (United States)

    Cho, Jongmin; Ibbott, Geoffrey; Gillin, Michael; Gonzalez-Lepera, Carlos; Titt, Uwe; Paganetti, Harald; Kerr, Matthew; Mawlawi, Osama

    2013-11-01

    Proton beam range verification using positron emission tomography (PET) currently relies on proton activation of tissue, the products of which decay with a short half-life and necessitate an on-site PET scanner. Tissue activation is, however, negligible near the distal dose fall-off region of the proton beam range due to their high interaction energy thresholds. Therefore Monte Carlo simulation is often supplemented for comparison with measurement; however, this also may be associated with systematic and statistical uncertainties. Therefore, we sought to test the feasibility of using long-lived proton-activated external materials that are inserted or infused into the target volume for more accurate proton beam range verification that could be performed at an off-site PET scanner. We irradiated samples of ≥98% 18O-enriched water, natural Cu foils, and >97% 68Zn-enriched foils as candidate materials, along with samples of tissue-equivalent materials including 16O water, heptane (C7H16), and polycarbonate (C16H14O3)n, at four depths (ranging from 100% to 3% of center of modulation (COM) dose) along the distal fall-off of a modulated 160 MeV proton beam. Samples were irradiated either directly or after being embedded in Plastic Water® or balsa wood. We then measured the activity of the samples using PET imaging for 20 or 30 min after various delay times. Measured activities of candidate materials were up to 100 times greater than those of the tissue-equivalent materials at the four distal dose fall-off depths. The differences between candidate materials and tissue-equivalent materials became more apparent after longer delays between irradiation and PET imaging, due to the longer half-lives of the candidate materials. Furthermore, the activation of the candidate materials closely mimicked the distal dose fall-off with offsets of 1 to 2 mm. Also, signals from the foils were clearly visible compared to the background from the activated Plastic Water® and balsa wood

  13. Complex movements, philopatry and expanded depth range of a severely threatened pelagic shark, the oceanic whitetip (Carcharhinus longimanus) in the western North Atlantic.

    Science.gov (United States)

    Howey-Jordan, Lucy A; Brooks, Edward J; Abercrombie, Debra L; Jordan, Lance K B; Brooks, Annabelle; Williams, Sean; Gospodarczyk, Emily; Chapman, Demian D

    2013-01-01

    Oceanic whitetip sharks (Carcharhinus longimanus) have recently been targeted for conservation in the western North Atlantic following severe declines in abundance. Pop-up satellite archival tags were applied to 11 mature oceanic whitetips (10 females, 1 male) near Cat Island in the central Bahamas 1-8 May 2011 to provide information about the horizontal and vertical movements of this species. Another large female was opportunistically tagged in the U.S. Exclusive Economic Zone (EEZ). Data from 1,563 total tracking days and 1,142,598 combined depth and temperature readings were obtained. Sharks tagged at Cat Island stayed within 500 km of the tagging site for ~30 days before dispersing across 16,422 km(2) of the western North Atlantic. Maximum individual displacement from the tagging site ranged from 290-1940 km after times at liberty from 30-245 days, with individuals moving to several different destinations (the northern Lesser Antilles, the northern Bahamas, and north of the Windward Passage). Many sharks returned to The Bahamas after ~150 days. Estimated residency times within The Bahamas EEZ, where longlining and commercial trade of sharks is illegal, were generally high (mean = 68.2% of time). Sharks spent 99.7% of their time shallower than 200 m and did not exhibit differences in day and night mean depths. There was a positive correlation between daily sea surface temperature and mean depth occupied, suggesting possible behavioral thermoregulation. All individuals made short duration (mean = 13.06 minutes) dives into the mesopelagic zone (down to 1082 m and 7.75°C), which occurred significantly more often at night. Ascent rates during these dives were significantly slower than descent rates, suggesting that these dives are for foraging. The sharks tracked appear to be most vulnerable to pelagic fishing gear deployed from 0-125 m depths, which they may encounter from June to October after leaving the protected waters of The Bahamas EEZ.

  14. Complex movements, philopatry and expanded depth range of a severely threatened pelagic shark, the oceanic whitetip (Carcharhinus longimanus in the western North Atlantic.

    Directory of Open Access Journals (Sweden)

    Lucy A Howey-Jordan

    Full Text Available Oceanic whitetip sharks (Carcharhinus longimanus have recently been targeted for conservation in the western North Atlantic following severe declines in abundance. Pop-up satellite archival tags were applied to 11 mature oceanic whitetips (10 females, 1 male near Cat Island in the central Bahamas 1-8 May 2011 to provide information about the horizontal and vertical movements of this species. Another large female was opportunistically tagged in the U.S. Exclusive Economic Zone (EEZ. Data from 1,563 total tracking days and 1,142,598 combined depth and temperature readings were obtained. Sharks tagged at Cat Island stayed within 500 km of the tagging site for ~30 days before dispersing across 16,422 km(2 of the western North Atlantic. Maximum individual displacement from the tagging site ranged from 290-1940 km after times at liberty from 30-245 days, with individuals moving to several different destinations (the northern Lesser Antilles, the northern Bahamas, and north of the Windward Passage. Many sharks returned to The Bahamas after ~150 days. Estimated residency times within The Bahamas EEZ, where longlining and commercial trade of sharks is illegal, were generally high (mean = 68.2% of time. Sharks spent 99.7% of their time shallower than 200 m and did not exhibit differences in day and night mean depths. There was a positive correlation between daily sea surface temperature and mean depth occupied, suggesting possible behavioral thermoregulation. All individuals made short duration (mean = 13.06 minutes dives into the mesopelagic zone (down to 1082 m and 7.75°C, which occurred significantly more often at night. Ascent rates during these dives were significantly slower than descent rates, suggesting that these dives are for foraging. The sharks tracked appear to be most vulnerable to pelagic fishing gear deployed from 0-125 m depths, which they may encounter from June to October after leaving the protected waters of The Bahamas EEZ.

  15. Depth profiling of tritium by neutron time-of-flight

    International Nuclear Information System (INIS)

    Davis, J.C.; Anderson, J.D.; Lefevre, H.W.

    1976-01-01

    A method to measure the depth profile of tritium implanted or absorbed in materials was developed. The sample to be analyzed is bombarded with a pulsed proton beam and the energy of neutrons produced by the T(p,n) reaction is measured by the time-of-flight technique. From the neutron energy the depth in the target of the T atoms may be inferred. A sensitivity of 0.1 at. percent T or greater is possible. The technique is non-destructive and may be used with thick or radioactive host materials. Samples up to 20 μm in thickness may be profiled with resolution limited by straggling of the proton beam for depths greater than 1 μm. Deuterium depth profiling has been demonstrated using the D(d,n) reaction. The technique has been used to observe the behavior of an implantation spike of T produced by a 400 keV T + beam stopping at a depth of 3 μm in 11 μm thick layers of Ti and TiH. The presence of H in the Ti lattice is observed to inhibit the diffusion of T through the lattice. Effects of the total hydrogen concentration (H + T) being forced above stochiometry at the implantation site are suggested by the shapes of the implantation spikes

  16. DEPTH-CHARGE static and time-dependent perturbation/sensitivity system for nuclear reactor core analysis. Revision I. [DEPTH-CHARGE code

    Energy Technology Data Exchange (ETDEWEB)

    White, J.R.

    1985-04-01

    This report provides the background theory, user input, and sample problems required for the efficient application of the DEPTH-CHARGE system - a code black for both static and time-dependent perturbation theory and data sensitivity analyses. The DEPTH-CHARGE system is of modular construction and has been implemented within the VENTURE-BURNER computational system at Oak Ridge National Laboratory. The DEPTH module (coupled with VENTURE) solves for the three adjoint functions of Depletion Perturbation Theory and calculates the desired time-dependent derivatives of the response with respect to the nuclide concentrations and nuclear data utilized in the reference model. The CHARGE code is a collection of utility routines for general data manipulation and input preparation and considerably extends the usefulness of the system through the automatic generation of adjoint sources, estimated perturbed responses, and relative data sensitivity coefficients. Combined, the DEPTH-CHARGE system provides, for the first time, a complete generalized first-order perturbation/sensitivity theory capability for both static and time-dependent analyses of realistic multidimensional reactor models. This current documentation incorporates minor revisions to the original DEPTH-CHARGE documentation (ORNL/CSD-78) to reflect some new capabilities within the individual codes.

  17. On the relationships between higher and lower bit-depth system measurements

    Science.gov (United States)

    Burks, Stephen D.; Haefner, David P.; Doe, Joshua M.

    2018-04-01

    The quality of an imaging system can be assessed through controlled laboratory objective measurements. Currently, all imaging measurements require some form of digitization in order to evaluate a metric. Depending on the device, the amount of bits available, relative to a fixed dynamic range, will exhibit quantization artifacts. From a measurement standpoint, measurements are desired to be performed at the highest possible bit-depth available. In this correspondence, we described the relationship between higher and lower bit-depth measurements. The limits to which quantization alters the observed measurements will be presented. Specifically, we address dynamic range, MTF, SiTF, and noise. Our results provide guidelines to how systems of lower bit-depth should be characterized and the corresponding experimental methods.

  18. SIMS as a new methodology to depth profile helium in as-implanted and annealed pure bcc metals?

    Energy Technology Data Exchange (ETDEWEB)

    Gorondy-Novak, S. [CEA, DEN, Service de Recherches de Métallurgie Physique, Université Paris-Saclay, F-91191 Gif-sur-Yvette (France); Jomard, F. [Groupe d' Etude de la Matière Condensée, CNRS, UVSQ, 45 avenue des Etats-Unis, 78035 Versailles cedex (France); Prima, F. [PSL Research University, Chimie ParisTech – CNRS, Institut de Recherche de Chimie Paris, 75005 Paris (France); Lefaix-Jeuland, H., E-mail: helene.lefaix@cea.fr [CEA, DEN, Service de Recherches de Métallurgie Physique, Université Paris-Saclay, F-91191 Gif-sur-Yvette (France)

    2017-05-01

    Reliable He profiles are highly desirable for better understanding helium behavior in materials for future nuclear applications. Recently, Secondary Ions Mass Spectrometry (SIMS) allowed the characterization of helium distribution in as-implanted metallic systems. The Cs{sup +} primary ion beam coupled with CsHe{sup +} molecular detector appeared to be a promising technique which overcomes the very high He ionization potential. In this study, {sup 4}He depth profiles in pure body centered cubic (bcc) metals (V, Fe, Ta, Nb and Mo) as-implanted and annealed, were obtained by SIMS. All as-implanted samples exhibited a projected range of around 200 nm, in agreement with SRIM theoretical calculations. After annealing treatment, SIMS measurements evidenced the evolution of helium depth profile with temperature. The latter SIMS results were compared to the helium bubble distribution obtained by Transmission Electron Microscopy (TEM). This study confirmed the great potential of this experimental procedure as a He-depth profiling technique in bcc metals. Indeed, the methodology described in this work could be extended to other materials including metallic and non-metallic compounds. Nevertheless, the quantification of helium concentration after annealing treatment by SIMS remains uncertain probably due to the non-uniform ionization efficiency in samples containing large bubbles.

  19. Fluctuating water depths affect American alligator (Alligator mississippiensis) body condition in the Everglades, Florida, USA

    Science.gov (United States)

    Brandt, Laura A.; Beauchamp, Jeffrey S.; Jeffery, Brian M.; Cherkiss, Michael S.; Mazzotti, Frank J.

    2016-01-01

    Successful restoration of wetland ecosystems requires knowledge of wetland hydrologic patterns and an understanding of how those patterns affect wetland plant and animal populations.Within the Everglades, Florida, USA restoration, an applied science strategy including conceptual ecological models linking drivers to indicators is being used to organize current scientific understanding to support restoration efforts. A key driver of the ecosystem affecting the distribution and abundance of organisms is the timing, distribution, and volume of water flows that result in water depth patterns across the landscape. American alligators (Alligator mississippiensis) are one of the ecological indicators being used to assess Everglades restoration because they are a keystone species and integrate biological impacts of hydrological operations through all life stages. Alligator body condition (the relative fatness of an animal) is one of the metrics being used and targets have been set to allow us to track progress. We examined trends in alligator body condition using Fulton’s K over a 15 year period (2000–2014) at seven different wetland areas within the Everglades ecosystem, assessed patterns and trends relative to restoration targets, and related those trends to hydrologic variables. We developed a series of 17 a priori hypotheses that we tested with an information theoretic approach to identify which hydrologic factors affect alligator body condition. Alligator body condition was highest throughout the Everglades during the early 2000s and is approximately 5–10% lower now (2014). Values have varied by year, area, and hydrology. Body condition was positively correlated with range in water depth and fall water depth. Our top model was the “Current” model and included variables that describe current year hydrology (spring depth, fall depth, hydroperiod, range, interaction of range and fall depth, interaction of range and hydroperiod). Across all models, interaction

  20. Modelling mid-span water table depth and drainage discharge ...

    African Journals Online (AJOL)

    Results of simulated WTDs at various combinations of drain depth and spacing indicated that in clay soil a WTD of 1.0 to 1.5 m from the soil surface can be achieved by installing drain pipes at drain spacing ranging from 25 to 40 m and drain depth between 1.4 and 1.8 m. On the other hand, in clay-loam soil, the same 1.0 to ...

  1. Extreme depth-of-field intraocular lenses

    Science.gov (United States)

    Baker, Kenneth M.

    1996-05-01

    A new technology brings the full aperture single vision pseudophakic eye's effective hyperfocal distance within the half-meter range. A modulated index IOL containing a subsurface zeroth order coherent microlenticular mosaic defined by an index gradient adds a normalizing function to the vergences or parallactic angles of incoming light rays subtended from field object points and redirects them, in the case of near-field images, to that of far-field images. Along with a scalar reduction of the IOL's linear focal range, this results in an extreme depth of field with a narrow depth of focus and avoids the focal split-up, halo, and inherent reduction in contrast of multifocal IOLs. A high microlenticular spatial frequency, which, while still retaining an anisotropic medium, results in a nearly total zeroth order propagation throughout the visible spectrum. The curved lens surfaces still provide most of the refractive power of the IOL, and the unique holographic fabrication technology is especially suitable not only for IOLs but also for contact lenses, artificial corneas, and miniature lens elements for cameras and other optical devices.

  2. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal; Schott, Mathias; Bonneau, Georges-Pierre; Hansen, Charles D.

    2013-01-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  3. Evaluation of Depth of Field for depth perception in DVR

    KAUST Repository

    Grosset, A.V.Pascal

    2013-02-01

    In this paper we present a user study on the use of Depth of Field for depth perception in Direct Volume Rendering. Direct Volume Rendering with Phong shading and perspective projection is used as the baseline. Depth of Field is then added to see its impact on the correct perception of ordinal depth. Accuracy and response time are used as the metrics to evaluate the usefulness of Depth of Field. The onsite user study has two parts: static and dynamic. Eye tracking is used to monitor the gaze of the subjects. From our results we see that though Depth of Field does not act as a proper depth cue in all conditions, it can be used to reinforce the perception of which feature is in front of the other. The best results (high accuracy & fast response time) for correct perception of ordinal depth occurs when the front feature (out of the two features users were to choose from) is in focus and perspective projection is used. © 2013 IEEE.

  4. Fish depth distributions in the Lower Mississippi River

    Science.gov (United States)

    Killgore, K. J.; Miranda, Leandro E.

    2014-01-01

    A substantial body of literature exists about depth distribution of fish in oceans, lakes and reservoirs, but less is known about fish depth distribution in large rivers. Most of the emphasis on fish distributions in rivers has focused on longitudinal and latitudinal spatial distributions. Knowledge on depth distribution is necessary to understand species and community habitat needs. Considering this void, our goal was to identify patterns in fish benthic distribution along depth gradients in the Lower Mississippi River. Fish were collected over 14 years in depths down to 27 m. Fish exhibited non-random depth distributions that varied seasonally and according to species. Species richness was highest in shallow water, with about 50% of the 62 species detected no longer collected in water deeper than 8 m and about 75% no longer collected in water deeper than 12 m. Although richness was highest in shallow water, most species were not restricted to shallow water. Rather, most species used a wide range of depths. A weak depth zonation occurred, not as strong as that reported for deep oceans and lakes. Larger fish tended to occur in deeper water during the high-water period of an annual cycle, but no correlation was evident during the low-water period. The advent of landscape ecology has guided river research to search for spatial patterns along the length of the river and associated floodplains. Our results suggest that fish assemblages in large rivers are also structured vertically. 

  5. Complications of medium depth and deep chemical peels

    Directory of Open Access Journals (Sweden)

    Nanma Nikalji

    2012-01-01

    Full Text Available Superficial and medium depth peels are dynamic tools when used as part of office procedures for treatment of acne, pigmentation disorders, and photo-aging. Results and complications are generally related to the depth of wounding, with deeper peels providing more marked results and higher incidence of complications. Complications are also more likely with darker skin types, certain peeling agents, and sun exposure. They can range from minor irritations, uneven pigmentation to permanent scarring. In very rare cases, complications can be life-threatening.

  6. Research of detection depth for graphene-based optical sensor

    Science.gov (United States)

    Yang, Yong; Sun, Jialve; Liu, Lu; Zhu, Siwei; Yuan, Xiaocong

    2018-03-01

    Graphene-based optical sensors have been developed for research into the biological intercellular refractive index (RI) because they offer greater detection depths than those provided by the surface plasmon resonance technique. In this Letter, we propose an experimental approach for measurement of the detection depth in a graphene-based optical sensor system that uses transparent polydimethylsiloxane layers with different thicknesses. The experimental results show that detection depths of 2.5 μm and 3 μm can be achieved at wavelengths of 532 nm and 633 nm, respectively. These results prove that graphene-based optical sensors can realize long-range RI detection and are thus promising for use as tools in the biological cell detection field. Additionally, we analyze the factors that influence the detection depth and provide a feasible approach for detection depth control based on adjustment of the wavelength and the angle of incidence. We believe that this approach will be useful in RI tomography applications.

  7. Efficient Depth Enhancement Using a Combination of Color and Depth Information.

    Science.gov (United States)

    Lee, Kyungjae; Ban, Yuseok; Lee, Sangyoun

    2017-07-01

    Studies on depth images containing three-dimensional information have been performed for many practical applications. However, the depth images acquired from depth sensors have inherent problems, such as missing values and noisy boundaries. These problems significantly affect the performance of applications that use a depth image as their input. This paper describes a depth enhancement algorithm based on a combination of color and depth information. To fill depth holes and recover object shapes, asynchronous cellular automata with neighborhood distance maps are used. Image segmentation and a weighted linear combination of spatial filtering algorithms are applied to extract object regions and fill disocclusion in the object regions. Experimental results on both real-world and public datasets show that the proposed method enhances the quality of the depth image with low computational complexity, outperforming conventional methods on a number of metrics. Furthermore, to verify the performance of the proposed method, we present stereoscopic images generated by the enhanced depth image to illustrate the improvement in quality.

  8. Quantum well saturable absorber mirror with electrical control of modulation depth

    DEFF Research Database (Denmark)

    Liu, Xiaomin; Rafailov, Edik U.; Livshits, Daniil

    2010-01-01

    in the range 2.5–0.5%, as measured by nonlinear reflectivity of 450 fs long laser pulses with 1065 nm central wavelength, in the pump fluence range 1.6–26.7 J /cm2. This electrical control of the modulation depth is achieved by controlling the small-signal loss of the SESAM via quantum-confined Stark effect......We demonstrate a quantum well QW semiconductor saturable absorber mirror SESAM comprising low-temperature grown InGaAs/GaAs QWs incorporated into a p-i-n structure. By applying the reverse bias voltage in the range 0–2 V to the p-i-n structure, we were able to change the SESAM modulation depth...

  9. Physical and biological factors determining the effective proton range

    International Nuclear Information System (INIS)

    Grün, Rebecca; Friedrich, Thomas; Krämer, Michael; Scholz, Michael; Zink, Klemens; Durante, Marco; Engenhart-Cabillic, Rita

    2013-01-01

    Purpose: Proton radiotherapy is rapidly becoming a standard treatment option for cancer. However, even though experimental data show an increase of the relative biological effectiveness (RBE) with depth, particularly at the distal end of the treatment field, a generic RBE of 1.1 is currently used in proton radiotherapy. This discrepancy might affect the effective penetration depth of the proton beam and thus the dose to the surrounding tissue and organs at risk. The purpose of this study was thus to analyze the impact of a tissue and dose dependent RBE of protons on the effective range of the proton beam in comparison to the range based on a generic RBE of 1.1.Methods: Factors influencing the biologically effective proton range were systematically analyzed by means of treatment planning studies using the Local Effect Model (LEM IV) and the treatment planning software TRiP98. Special emphasis was put on the comparison of passive and active range modulation techniques.Results: Beam energy, tissue type, and dose level significantly affected the biological extension of the treatment field at the distal edge. Up to 4 mm increased penetration depth as compared to the depth based on a constant RBE of 1.1. The extension of the biologically effective range strongly depends on the initial proton energy used for the most distal layer of the field and correlates with the width of the distal penumbra. Thus, the range extension, in general, was more pronounced for passive as compared to active range modulation systems, whereas the maximum RBE was higher for active systems.Conclusions: The analysis showed that the physical characteristics of the proton beam in terms of the width of the distal penumbra have a great impact on the RBE gradient and thus also the biologically effective penetration depth of the beam

  10. Range walk error correction and modeling on Pseudo-random photon counting system

    Science.gov (United States)

    Shen, Shanshan; Chen, Qian; He, Weiji

    2017-08-01

    Signal to noise ratio and depth accuracy are modeled for the pseudo-random ranging system with two random processes. The theoretical results, developed herein, capture the effects of code length and signal energy fluctuation are shown to agree with Monte Carlo simulation measurements. First, the SNR is developed as a function of the code length. Using Geiger-mode avalanche photodiodes (GMAPDs), longer code length is proven to reduce the noise effect and improve SNR. Second, the Cramer-Rao lower bound on range accuracy is derived to justify that longer code length can bring better range accuracy. Combined with the SNR model and CRLB model, it is manifested that the range accuracy can be improved by increasing the code length to reduce the noise-induced error. Third, the Cramer-Rao lower bound on range accuracy is shown to converge to the previously published theories and introduce the Gauss range walk model to range accuracy. Experimental tests also converge to the presented boundary model in this paper. It has been proven that depth error caused by the fluctuation of the number of detected photon counts in the laser echo pulse leads to the depth drift of Time Point Spread Function (TPSF). Finally, numerical fitting function is used to determine the relationship between the depth error and the photon counting ratio. Depth error due to different echo energy is calibrated so that the corrected depth accuracy is improved to 1cm.

  11. Estimation of radon concentration in soil and groundwater samples of Northern Rajasthan, India

    International Nuclear Information System (INIS)

    Mittal, Sudhir; Asha Rani; Mehra, Rohit

    2015-01-01

    In the present investigation, analysis of radon concentration in 20 water and soil samples collected from different locations of Bikaner and Jhunjhunu districts of Rajasthan, India has been carried out by using RAD7 an electronic Radon detector. The water samples are taken from hand pumps and tube wells having depths ranging from 50 to 600 feet. All the soil gas measurements have been carried out at 100 cm depth. The measured radon concentration in water samples lies in the range from 0.50 to 22 Bq l -1 with the mean value of 4.42 Bq l -1 . Only in one water sample radon concentration is found to be higher than the safe limit of 11 Bq l -1 recommended US Environmental Protection Agency (USEPA, 1991). The measured value of radon concentration in all ground water samples is within the safe limit from 4 to 40 Bq l -1 recommended by United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR, 2008). The total annual effective dose estimated due to radon concentration in water ranges from 1.37 to 60 μSV y -1 with the mean value of 12.08 μSV y -1 . The total annual effective dose from all locations of our studied area is found to be well within the safe limit 0.1 mSv y -1 recommended by World Health Organization (WHO, 2004) and European Council (ED, 1998). Radon measurement in soil samples varies from 941 to 10050 Bq m -3 with the mean value of 4561 Bq m -3 , The radon concentration observed from the soil samples from our study area lies within the range reported by other investigators. Moreover a positive correlation of radon concentration in water with soil samples has been observed. It was observed that the soil and water of Bikaner and Jhunjhunu districts are suitable for drinking and construction purpose without posing any health hazard. (author)

  12. Development of Cold Neutron Depth Profiling System at HANARO

    International Nuclear Information System (INIS)

    Park, B. G.; Choi, H. D.; Sun, G. M.

    2012-01-01

    The depth profiles of intentional or intrinsic constituents of a sample provide valuable information for the characterization of materials. A number of analytical techniques for depth profiling have been developed. Neutron Depth Profiling (NDP) system which was developed by Ziegler et al. is one of the leading analytical techniques. In NDP, a thermal or cold neutron beam passes through a material and interacts with certain isotopes that are known to emit monoenergetic-charged particle remaining a recoil nucleus after neutron absorption. The depth is obtained from the energy loss of those charged particles escaping surface of substrate material. For various applications of NDP technique, the Cold Neutron Depth Profiling System (CN-NDP) was developed at a neutron guide CG1 installed at the HANARO cold neutron source. In this study the design features of the cold neutron beam and target chamber for the CN-NDP system are given. Also, some experiments for the performance tests of the CN-NDP system are described

  13. Depth resolution and preferential sputtering in depth profiling of sharp interfaces

    International Nuclear Information System (INIS)

    Hofmann, S.; Han, Y.S.; Wang, J.Y.

    2017-01-01

    Highlights: • Interfacial depth resolution from MRI model depends on sputtering rate differences. • Depth resolution critically depends on the dominance of roughness or atomic mixing. • True (depth scale) and apparent (time scale) depth resolutions are different. • Average sputtering rate approximately yields true from apparent depth resolution. • Profiles by SIMS and XPS are different but similar to surface concentrations. - Abstract: The influence of preferential sputtering on depth resolution of sputter depth profiles is studied for different sputtering rates of the two components at an A/B interface. Surface concentration and intensity depth profiles on both the sputtering time scale (as measured) and the depth scale are obtained by calculations with an extended Mixing-Roughness-Information depth (MRI)-model. The results show a clear difference for the two extreme cases (a) preponderant roughness and (b) preponderant atomic mixing. In case (a), the interface width on the time scale (Δt(16–84%)) increases with preferential sputtering if the faster sputtering component is on top of the slower sputtering component, but the true resolution on the depth scale (Δz(16–84%)) stays constant. In case (b), the interface width on the time scale stays constant but the true resolution on the depth scale varies with preferential sputtering. For similar order of magnitude of the atomic mixing and the roughness parameters, a transition state between the two extremes is obtained. While the normalized intensity profile of SIMS represents that of the surface concentration, an additional broadening effect is encountered in XPS or AES by the influence of the mean electron escape depth which may even cause an additional matrix effect at the interface.

  14. Depth resolution and preferential sputtering in depth profiling of sharp interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, S. [Max Planck Institute for Intelligent Systems (formerly MPI for Metals Research), Heisenbergstrasse 3, D-70569 Stuttgart (Germany); Han, Y.S. [Department of Physics, Shantou University, 243 Daxue Road, Shantou, 515063 Guangdong (China); Wang, J.Y., E-mail: wangjy@stu.edu.cn [Department of Physics, Shantou University, 243 Daxue Road, Shantou, 515063 Guangdong (China)

    2017-07-15

    Highlights: • Interfacial depth resolution from MRI model depends on sputtering rate differences. • Depth resolution critically depends on the dominance of roughness or atomic mixing. • True (depth scale) and apparent (time scale) depth resolutions are different. • Average sputtering rate approximately yields true from apparent depth resolution. • Profiles by SIMS and XPS are different but similar to surface concentrations. - Abstract: The influence of preferential sputtering on depth resolution of sputter depth profiles is studied for different sputtering rates of the two components at an A/B interface. Surface concentration and intensity depth profiles on both the sputtering time scale (as measured) and the depth scale are obtained by calculations with an extended Mixing-Roughness-Information depth (MRI)-model. The results show a clear difference for the two extreme cases (a) preponderant roughness and (b) preponderant atomic mixing. In case (a), the interface width on the time scale (Δt(16–84%)) increases with preferential sputtering if the faster sputtering component is on top of the slower sputtering component, but the true resolution on the depth scale (Δz(16–84%)) stays constant. In case (b), the interface width on the time scale stays constant but the true resolution on the depth scale varies with preferential sputtering. For similar order of magnitude of the atomic mixing and the roughness parameters, a transition state between the two extremes is obtained. While the normalized intensity profile of SIMS represents that of the surface concentration, an additional broadening effect is encountered in XPS or AES by the influence of the mean electron escape depth which may even cause an additional matrix effect at the interface.

  15. Bit-depth scalable video coding with new inter-layer prediction

    Directory of Open Access Journals (Sweden)

    Chiang Jui-Chiu

    2011-01-01

    Full Text Available Abstract The rapid advances in the capture and display of high-dynamic range (HDR image/video content make it imperative to develop efficient compression techniques to deal with the huge amounts of HDR data. Since HDR device is not yet popular for the moment, the compatibility problems should be considered when rendering HDR content on conventional display devices. To this end, in this study, we propose three H.264/AVC-based bit-depth scalable video-coding schemes, called the LH scheme (low bit-depth to high bit-depth, the HL scheme (high bit-depth to low bit-depth, and the combined LH-HL scheme, respectively. The schemes efficiently exploit the high correlation between the high and the low bit-depth layers on the macroblock (MB level. Experimental results demonstrate that the HL scheme outperforms the other two schemes in some scenarios. Moreover, it achieves up to 7 dB improvement over the simulcast approach when the high and low bit-depth representations are 12 bits and 8 bits, respectively.

  16. Post-cure depth of cure of bulk fill dental resin-composites.

    Science.gov (United States)

    Alrahlah, A; Silikas, N; Watts, D C

    2014-02-01

    To determine the post-cure depth of cure of bulk fill resin composites through using Vickers hardness profiles (VHN). Five bulk fill composite materials were examined: Tetric EvoCeram(®) Bulk Fill, X-tra base, Venus(®) Bulk Fill, Filtek™ Bulk Fill, SonicFill™. Three specimens of each material type were prepared in stainless steel molds which contained a slot of dimensions (15 mm × 4 mm × 2 mm), and a top plate. The molds were irradiated from one end. All specimens were stored at 37°C for 24h, before measurement. The Vickers hardness was measured as a function of depth of material, at 0.3mm intervals. Data were analysed by one-way ANOVA using Tukey post hoc tests (α=0.05). The maximum VHN ranged from 37.8 to 77.4, whilst the VHN at 80% of max.VHN ranged from 30.4 to 61.9. The depth corresponding to 80% of max.VHN, ranged from 4.14 to 5.03 mm. One-way ANOVA showed statistically significant differences between materials for all parameters tested. SonicFill exhibited the highest VHN (pFill the lowest (p≤0.001). SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure (5.03 and 4.47 mm, respectively) and was significant's different from X-tra base, Venus Bulk Fill and Filtek Bulk Fill (p≤0.016). Linear regression confirmed a positive regression between max.VHN and filler loading (r(2)=0.94). Bulk fill resin composites can be cured to an acceptable post-cure depth, according to the manufacturers' claims. SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure among the composites examined. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  17. Photothermal radiometric determination of thermal diffusivity depth profiles in a dental resin

    International Nuclear Information System (INIS)

    MartInez-Torres, P; Alvarado-Gil, J J; Mandelis, A

    2010-01-01

    The depth of curing due to photopolymerization in a commercial dental resin is studied using photothermal radiometry. The sample consists of a thick layer of resin on which a thin metallic layer is deposited guaranteeing full opacity of the sample. In this case, purely thermal-wave inverse problem techniques without the interference of optical profiles can be used. Thermal profiles are obtained by heating the coating with a modulated laser beam and performing a modulation frequency scan. Before each frequency scan, photopolymerization was induced using a high power blue LED. However due to the fact that dental resins are highly light dispersive materials, the polymerization process depends strongly on the optical absorption coefficient inducing a depth dependent thermal diffusion in the sample. It is shown that using a robust depth profilometric inverse method one can reconstruct the thermal diffusivity profile of the photopolymerized resin.

  18. Spectrally and spatially resolved photoluminescence. Lateral fluctuations and depth profiles of Cu(In,Ga)Se2-absorbers

    International Nuclear Information System (INIS)

    Neumann, Oliver

    2013-01-01

    The aim of this thesis is the development and refinement of photoluminescence (PL) methods for inhomogeneous absorbers to identify lateral fluctuations and depth-dependent variations of spectroscopic, optical and opto-electronic properties in the submicron/micron range. The first approach deals with the spectral investigation of PL emission from the front and the rear side of an absorber, whereas the second idea is about the analysis of PL spectra from the front side of the absorber for different absorber thicknesses. Another technique for determination of depth-dependent variations are confocal PL measurements at cross sections of absorbers. The last concept pursues the study of lateral fluctuations with an optical near-field microscope on specially prepared absorbers. These four strategies are demonstrated with samples based on Cu(In,Ga)Se 2 .

  19. Depth Profiles in Maize ( Zea mays L.) Seeds Studied by Photoacoustic Spectroscopy

    Science.gov (United States)

    Hernández-Aguilar, C.; Domínguez-Pacheco, A.; Cruz-Orea, A.; Zepeda-Bautista, R.

    2015-06-01

    Photoacoustic spectroscopy (PAS) has been used to analyze agricultural seeds and can be applied to the study of seed depth profiles of these complex samples composed of different structures. The sample depth profile can be obtained through the photoacoustic (PA) signal, amplitude, and phase at different light modulation frequencies. The PA signal phase is more sensitive to changes of thermal properties in layered samples than the PA signal amplitude. Hence, the PA signal phase can also be used to characterize layers at different depths. Thus, the objective of the present study was to obtain the optical absorption spectra of maize seeds ( Zea mays L.) by means of PAS at different light modulation frequencies (17 Hz, 30 Hz, and 50 Hz) and comparing these spectra with the ones obtained from the phase-resolved method in order to separate the optical absorption spectra of seed pericarp and endosperm. The results suggest the possibility of using the phase-resolved method to obtain optical absorption spectra of different seed structures, at different depths, without damaging the seed. Thus, PAS could be a nondestructive method for characterization of agricultural seeds and thus improve quality control in the food industry.

  20. Development and Applications of Time of Flight Neutron Depth Profiling

    International Nuclear Information System (INIS)

    Cady, Bingham; Unlu, Kenan

    2005-01-01

    The depth profiles of intentional or intrinsic constituents of a sample provide valuable information for the characterization of materials. For example, the subtle differences in spatial distribution and composition of many chemical species in the near surface region and across interfacial boundaries can significantly alter the electronic and optical properties of materials. A number of analytical techniques for depth profiling have been developed during the last two decades. neutron Depth Profiling (NDP) is one of the leading analytical techniques. The NDP is a nondestructive near surface technique that utilizes thermal/cold neutron beam to measure the concentration of specific light elements versus their depth in materials. The depth is obtained from the energy loss of protons, alphas or recoil atoms in substrate materials. Since the charged particle energy determination using surface barrier detector is used for NDP, the depth resolution is highly dependent on the detectors an d detection instruments. The depth resolutions of a few tens of nm are achieved with available NDP facilities in the world. However, the performance of NDP needs to be improved in order to obtain a few A depth resolutions

  1. Soil depth profiles and radiological assessment of natural radionuclides in forest ecosystem

    International Nuclear Information System (INIS)

    Manigandan, P.K.; Chandar Shekar, B.

    2017-01-01

    We measured the distribution of three naturally occurring radionuclides, "2"3"8U, "2"3"2Th, and "4"0K, in soil samples collected from a rainforest in the Western Ghats of India. For each surface sample, we calculated average activity concentration, outdoor terrestrial γ dose rate, annual effective dose equivalent (AEDE), and radiation hazard index. The activity concentrations of surface samples were randomly distributed over space, but differed slightly with different soil depths. The concentration of "2"3"2Th and the average terrestrial γ dose rates were slightly higher than the world averages, so slightly high γ radiation appears to be a general characteristic of the Western Ghats. However, all radiological hazard indices were within the limits proposed by the International Commission on Radiological Protection. The results reported here indicate that, except for "2"3"2Th, the naturally occurring radionuclides in the forest soils of the Western Ghats were within the ranges specified by United Nations Scientific Committee on the Effects of Atomic Radiation for undisturbed virgin soils.

  2. Soil depth profiles and radiological assessment of natural radionuclides in forest ecosystem

    Energy Technology Data Exchange (ETDEWEB)

    Manigandan, P.K. [Al Musanna College of Technology, Muscat (Oman); Chandar Shekar, B. [Bharathiar Univ., Coimbatore (India). Kongunadu Arts and Science College

    2017-08-01

    We measured the distribution of three naturally occurring radionuclides, {sup 238}U, {sup 232}Th, and {sup 40}K, in soil samples collected from a rainforest in the Western Ghats of India. For each surface sample, we calculated average activity concentration, outdoor terrestrial γ dose rate, annual effective dose equivalent (AEDE), and radiation hazard index. The activity concentrations of surface samples were randomly distributed over space, but differed slightly with different soil depths. The concentration of {sup 232}Th and the average terrestrial γ dose rates were slightly higher than the world averages, so slightly high γ radiation appears to be a general characteristic of the Western Ghats. However, all radiological hazard indices were within the limits proposed by the International Commission on Radiological Protection. The results reported here indicate that, except for {sup 232}Th, the naturally occurring radionuclides in the forest soils of the Western Ghats were within the ranges specified by United Nations Scientific Committee on the Effects of Atomic Radiation for undisturbed virgin soils.

  3. Effect of bench time polymerization on depth of cure of dental composite resin

    Science.gov (United States)

    Harahap, K.; Yudhit, A.; Sari, F.

    2017-07-01

    The aim of this research was to investigate the effect of bench time before light cured polymerization on the depth of cure of dental composite resin. Nanofiller composite resin (Filtek Z350 XT,3M, ESPE,China) was used in this study. Sixty samples of nanofiller composite resin were made and divided into control and test groups with bench time for 0, 15, 30, 45, and 60 min. For the test group, composite resins were stored in refrigerator with 4°C temperatures. Meanwhile, for the control groups, the composite resin was stored at room temperature. The samples were prepared using metal mould with size diameter of 6 mm and 4 mm in thickness. Samples were cured for 20 s by using visible blue light curing unit. Part of samples that unpolymerized were removed by using a plastic spatula. The remaining parts of samples were measured by digital caliper and noted as depth of cure (mm). Data were analyzed to one-way ANOVA and LSD tests (p≤0.05). Results showed there was no significance differences between test groups (p=0.5). A 60 minutes bench time group showed the highest depth of cure value among test group, and it was almost similar with control group value. It can be concluded that longer bench time can increase the depth of cure of composite resin.

  4. The Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc.

    Science.gov (United States)

    Lee, Do-Youl; Kim, Se-Hoon; Suh, Jung-Keun; Cho, Tai-Hyoung; Chung, Yong-Gu

    2012-09-01

    This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. A retrospective radiological analysis was performed in 50 patients who had undergone single level total disc replacement surgery. Records were reviewed to obtain demographic data. Preoperative and postoperative radiographs were assessed to determine C2-7 Cobb's angle and segmental angle and to investigate postoperative kyphotic deformity. A formula was introduced to calculate insertion depth of Prodisc-C artificial disc. Statistical analysis was performed to search the correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity, and to estimate insertion depth of Prodisc-C artificial disc to prevent postoperative kyphotic deformity. In this study no significant statistical correlation was observed between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity regarding C2-7 Cobb's angle. Statistical correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity was observed regarding segmental angle (p<0.05). It failed to estimate proper insertion depth of Prodisc-C artificial disc effective in preventing postoperative kyphotic deformity. Postoperative segmental kyphotic deformity is associated with insertion depth of Prodisc-C artificial disc. Anterior located artificial disc leads to lordotic segmental angle and posterior located artificial disc leads to kyphotic segmental angle postoperatively. But C2-7 Cobb's angle is not affected by artificial disc location after the surgery.

  5. Hydrogen analysis depth calibration by CORTEO Monte-Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Moser, M., E-mail: marcus.moser@unibw.de [Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik LRT2, Fakultät für Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany); Reichart, P.; Bergmaier, A.; Greubel, C. [Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik LRT2, Fakultät für Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany); Schiettekatte, F. [Université de Montréal, Département de Physique, Montréal, QC H3C 3J7 (Canada); Dollinger, G., E-mail: guenther.dollinger@unibw.de [Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik LRT2, Fakultät für Luft- und Raumfahrttechnik, 85577 Neubiberg (Germany)

    2016-03-15

    Hydrogen imaging with sub-μm lateral resolution and sub-ppm sensitivity has become possible with coincident proton–proton (pp) scattering analysis (Reichart et al., 2004). Depth information is evaluated from the energy sum signal with respect to energy loss of both protons on their path through the sample. In first order, there is no angular dependence due to elastic scattering. In second order, a path length effect due to different energy loss on the paths of the protons causes an angular dependence of the energy sum. Therefore, the energy sum signal has to be de-convoluted depending on the matrix composition, i.e. mainly the atomic number Z, in order to get a depth calibrated hydrogen profile. Although the path effect can be calculated analytically in first order, multiple scattering effects lead to significant deviations in the depth profile. Hence, in our new approach, we use the CORTEO Monte-Carlo code (Schiettekatte, 2008) in order to calculate the depth of a coincidence event depending on the scattering angle. The code takes individual detector geometry into account. In this paper we show, that the code correctly reproduces measured pp-scattering energy spectra with roughness effects considered. With more than 100 μm thick Mylar-sandwich targets (Si, Fe, Ge) we demonstrate the deconvolution of the energy spectra on our current multistrip detector at the microprobe SNAKE at the Munich tandem accelerator lab. As a result, hydrogen profiles can be evaluated with an accuracy in depth of about 1% of the sample thickness.

  6. Depth Dose Measurement using a Scintillating Fiber Optic Dosimeter for Proton Therapy Beam of the Passive-Scattering Mode Having Range Modulator Wheel

    Science.gov (United States)

    Hwang, Ui-Jung; Shin, Dongho; Lee, Se Byeong; Lim, Young Kyung; Jeong, Jong Hwi; Kim, Hak Soo; Kim, Ki Hwan

    2018-05-01

    To apply a scintillating fiber dosimetry system to measure the range of a proton therapy beam, a new method was proposed to correct for the quenching effect on measuring an spread out Bragg peak (SOBP) proton beam whose range is modulated by a range modulator wheel. The scintillating fiber dosimetry system was composed of a plastic scintillating fiber (BCF-12), optical fiber (SH 2001), photo multiplier tube (H7546), and data acquisition system (PXI6221 and SCC68). The proton beam was generated by a cyclotron (Proteus-235) in the National Cancer Center in Korea. It operated in the double-scattering mode and the spread out of the Bragg peak was achieved by a spinning range modulation wheel. Bragg peak beams and SOBP beams of various ranges were measured, corrected, and compared to the ion chamber data. For the Bragg peak beam, quenching equation was used to correct the quenching effect. On the proposed process of correcting SOBP beams, the measured data using a scintillating fiber were separated by the Bragg peaks that the SOBP beam contained, and then recomposed again to reconstruct an SOBP after correcting for each Bragg peak. The measured depth-dose curve for the single Bragg peak beam was well corrected by using a simple quenching equation. Correction for SOBP beam was conducted with a newly proposed method. The corrected SOBP signal was in accordance with the results measured with an ion chamber. We propose a new method to correct for the SOBP beam from the quenching effect in a scintillating fiber dosimetry system. This method can be applied to other scintillator dosimetry for radiation beams in which the quenching effect is shown in the scintillator.

  7. Broad-Range Bacterial Capture from Fluid-Samples: Implications for Amplification-Free Contamination Detection

    Directory of Open Access Journals (Sweden)

    Monika WEBER

    2016-08-01

    Full Text Available Fluid-Screen, Inc. presents a bacterial concentration and filtration method based on dielectrophoresis and alternating current kinetics. Dielectrophoresis has been previously shown to induce particle motion; however, bacterial capture efficiency and reproducibility have consistently been low, reducing its potential for practical applications. In this study, we introduce a novel, patent-pending electrode system optimized to simultaneously capture a wide range of bacterial species from a variety of aqueous solutions. Specifically, we show that the method of dielectrophoresis used induces responses in both characteristic Gram- negative Escherichia coli and Gram-positive Enterococcus faecalis bacteria, as well as with Bacillus subtilis and Aestuariimicrobium kwangyangense. We have adapted the electrode design to create a bacterial sample preparatio unit, termed the sample sorter, that is able to capture multiple bacterial species and release them simultaneously for bacterial concentration and exchange from complex matrices to defined buffer media. This technology can be used on its own or in conjunction with standard bacterial detection methods such as mass spectroscopy. The Fluid-Screen product will dramatically improve testing and identification of bacterial contaminants in various industrial settings by eliminating the need for amplification of samples and by reducing the time to identification.

  8. Temporal consistent depth map upscaling for 3DTV

    Science.gov (United States)

    Schwarz, Sebastian; Sjöström, Mârten; Olsson, Roger

    2014-03-01

    The ongoing success of three-dimensional (3D) cinema fuels increasing efforts to spread the commercial success of 3D to new markets. The possibilities of a convincing 3D experience at home, such as three-dimensional television (3DTV), has generated a great deal of interest within the research and standardization community. A central issue for 3DTV is the creation and representation of 3D content. Acquiring scene depth information is a fundamental task in computer vision, yet complex and error-prone. Dedicated range sensors, such as the Time­ of-Flight camera (ToF), can simplify the scene depth capture process and overcome shortcomings of traditional solutions, such as active or passive stereo analysis. Admittedly, currently available ToF sensors deliver only a limited spatial resolution. However, sophisticated depth upscaling approaches use texture information to match depth and video resolution. At Electronic Imaging 2012 we proposed an upscaling routine based on error energy minimization, weighted with edge information from an accompanying video source. In this article we develop our algorithm further. By adding temporal consistency constraints to the upscaling process, we reduce disturbing depth jumps and flickering artifacts in the final 3DTV content. Temporal consistency in depth maps enhances the 3D experience, leading to a wider acceptance of 3D media content. More content in better quality can boost the commercial success of 3DTV.

  9. Combined evaluation of grazing incidence X-ray fluorescence and X-ray reflectivity data for improved profiling of ultra-shallow depth distributions

    Energy Technology Data Exchange (ETDEWEB)

    Ingerle, D., E-mail: dingerle@ati.ac.at [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Meirer, F. [Inorganic Chemistry and Catalysis, Debye Institute for Nanomaterials Science, Utrecht University, Universiteitsweg 99, 3584 CG Utrecht (Netherlands); Pepponi, G.; Demenev, E.; Giubertoni, D. [MiNALab, CMM-irst, Fondazione Bruno Kessler, Via Sommarive 18, I-38050 Povo (Italy); Wobrauschek, P.; Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria)

    2014-09-01

    The continuous downscaling of the process size for semiconductor devices pushes the junction depths and consequentially the implantation depths to the top few nanometers of the Si substrate. This motivates the need for sensitive methods capable of analyzing dopant distribution, total dose and possible impurities. X-ray techniques utilizing the external reflection of X-rays are very surface sensitive, hence providing a non-destructive tool for process analysis and control. X-ray reflectometry (XRR) is an established technique for the characterization of single- and multi-layered thin film structures with layer thicknesses in the nanometer range. XRR spectra are acquired by varying the incident angle in the grazing incidence regime while measuring the specular reflected X-ray beam. The shape of the resulting angle-dependent curve is correlated to changes of the electron density in the sample, but does not provide direct information on the presence or distribution of chemical elements in the sample. Grazing Incidence XRF (GIXRF) measures the X-ray fluorescence induced by an X-ray beam incident under grazing angles. The resulting angle dependent intensity curves are correlated to the depth distribution and mass density of the elements in the sample. GIXRF provides information on contaminations, total implanted dose and to some extent on the depth of the dopant distribution, but is ambiguous with regard to the exact distribution function. Both techniques use similar measurement procedures and data evaluation strategies, i.e. optimization of a sample model by fitting measured and calculated angle curves. Moreover, the applied sample models can be derived from the same physical properties, like atomic scattering/form factors and elemental concentrations; a simultaneous analysis is therefore a straightforward approach. This combined analysis in turn reduces the uncertainties of the individual techniques, allowing a determination of dose and depth profile of the implanted

  10. Hydrogen depth resolution in multilayer metal structures, comparison of elastic recoil detection and resonant nuclear reaction method

    Energy Technology Data Exchange (ETDEWEB)

    Wielunski, L.S. E-mail: leszekw@optushome.com.au; Grambole, D.; Kreissig, U.; Groetzschel, R.; Harding, G.; Szilagyi, E

    2002-05-01

    Four different metals: Al, Cu, Ag and Au have been used to produce four special multilayer samples to study the depth resolution of hydrogen. The layer structure of each sample was analysed using 2 MeV He Rutherford backscattering spectrometry, 4.5 MeV He elastic recoil detection (ERD) and 30 MeV F{sup 6+} HIERD. Moreover the hydrogen distribution was analysed in all samples using H({sup 15}N, {alpha}{gamma}){sup 12}C nuclear reaction analysis (NRA) with resonance at 6.385 MeV. The results show that the best depth resolution and sensitivity for hydrogen detection are offered by resonance NRA. The He ERD shows good depth resolution only for the near surface hydrogen. In this technique the depth resolution is rapidly reduced with depth due to multiple scattering effects. The 30 MeV F{sup 6+} HIERD demonstrated similar hydrogen depth resolution to He ERD for low mass metals and HIERD resolution is substantially better for heavy metals and deep layers.

  11. Seasonal and depth effects on some parameters of a forest soil

    Directory of Open Access Journals (Sweden)

    Dimas Augusto Morozin Zaia

    2009-03-01

    Full Text Available The main goal of this paper is to study the effect of wet/dry season and the depth on several parameters of the forest soil. This work has shown that the concentration of Al3+ increases and that the concentration of exchangeable cations (Ca2+, Mg2+ and pHs (distilled water and CaCl2 decreases with the increase in depth and that these results are correlated. The concentrations of exchangeable cations (Al3+, Ca2+, Mg2+ and organic matter (OM are affected by dry/wet season. Rain increases the solubility of organic carbon, thus decreasing OM and releasing exchangeable cations (Al3+, Ca2+, Mg2+. P (available shows an increase in its concentration with an increase in depth. The low concentration of P (available in the soil samples could be due to the low pH of the soils. The value of pHpzc is influenced by exchangeable cations (Al3+, Ca2+, Mg2+, and the pHs (CaCl2 and distilled water are higher than pHpzc. This means that the net charge of these soils is negative. CEC and CECpotential decrease with the increase in depth in most soil samples. For mostly of the samples, the season (wet/dry does not affect CEC, CECpotential, K+, or Na+.

  12. Measuring depth profiles of residual stress with Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Enloe, W.S.; Sparks, R.G.; Paesler, M.A.

    1988-12-01

    Knowledge of the variation of residual stress is a very important factor in understanding the properties of machined surfaces. The nature of the residual stress can determine a part`s susceptibility to wear deformation, and cracking. Raman spectroscopy is known to be a very useful technique for measuring residual stress in many materials. These measurements are routinely made with a lateral resolution of 1{mu}m and an accuracy of 0.1 kbar. The variation of stress with depth; however, has not received much attention in the past. A novel technique has been developed that allows quantitative measurement of the variation of the residual stress with depth with an accuracy of 10nm in the z direction. Qualitative techniques for determining whether the stress is varying with depth are presented. It is also demonstrated that when the stress is changing over the volume sampled, errors can be introduced if the variation of the stress with depth is ignored. Computer aided data analysis is used to determine the depth dependence of the residual stress.

  13. Characterization of a fluvial aquifer at a range of depths and scales: the Triassic St Bees Sandstone Formation, Cumbria, UK

    Science.gov (United States)

    Medici, Giacomo; West, L. J.; Mountney, N. P.

    2018-03-01

    Fluvial sedimentary successions represent porous media that host groundwater and geothermal resources. Additionally, they overlie crystalline rocks hosting nuclear waste repositories in rift settings. The permeability characteristics of an arenaceous fluvial succession, the Triassic St Bees Sandstone Formation in England (UK), are described, from core-plug to well-test scale up to 1 km depth. Within such lithified successions, dissolution associated with the circulation of meteoric water results in increased permeability ( K 10-1-100 m/day) to depths of at least 150 m below ground level (BGL) in aquifer systems that are subject to rapid groundwater circulation. Thus, contaminant transport is likely to occur at relatively high rates. In a deeper investigation (> 150 m depth), where the aquifer has not been subjected to rapid groundwater circulation, well-test-scale hydraulic conductivity is lower, decreasing from K 10-2 m/day at 150-400 m BGL to 10-3 m/day down-dip at 1 km BGL, where the pore fluid is hypersaline. Here, pore-scale permeability becomes progressively dominant with increasing lithostatic load. Notably, this work investigates a sandstone aquifer of fluvial origin at investigation depths consistent with highly enthalpy geothermal reservoirs ( 0.7-1.1 km). At such depths, intergranular flow dominates in unfaulted areas with only minor contribution by bedding plane fractures. However, extensional faults represent preferential flow pathways, due to presence of high connective open fractures. Therefore, such faults may (1) drive nuclear waste contaminants towards the highly permeable shallow (< 150 m BGL) zone of the aquifer, and (2) influence fluid recovery in geothermal fields.

  14. Using elastic peak electron spectroscopy for enhanced depth resolution in sputter profiling

    International Nuclear Information System (INIS)

    Hofmann, S.; Kesler, V.

    2002-01-01

    Elastic peak electron spectroscopy (EPES) is an alternative to AES in sputter depth profiling of thin film structures. In contrast to AES, EPES depth profiling is not influenced by chemical effects. The high count rate ensures a good signal to noise ratio, that is lower measurement times and/or higher precision. In addition, because of the elastically scattered electrons travel twice through the sample, the effective escape depth is reduced, an important factor for the depth resolution function. Thus, the depth resolution is increased. EPES depth profiling was successfully applied to a Ge/Si multilayer structure. For an elastic peak energy of 1.0 keV the information depth is considerably lower (0.8 nm) as compared to the Ge (LMM, 1147 eV) peak (1.6 nm) used in AES depth profiling, resulting in a respectively improved depth resolution for EPES profiling under otherwise similar profiling conditions. EPES depth profiling is successfully applied to measure small diffusion lengths at Ge/Si interfaces of the order of 1 nm. (Authors)

  15. An optical fiber expendable seawater temperature/depth profile sensor

    Science.gov (United States)

    Zhao, Qiang; Chen, Shizhe; Zhang, Keke; Yan, Xingkui; Yang, Xianglong; Bai, Xuejiao; Liu, Shixuan

    2017-10-01

    Marine expendable temperature/depth profiler (XBT) is a disposable measuring instrument which can obtain temperature/depth profile data quickly in large area waters and mainly used for marine surveys, scientific research, military application. The temperature measuring device is a thermistor in the conventional XBT probe (CXBT)and the depth data is only a calculated value by speed and time depth calculation formula which is not an accurate measurement result. Firstly, an optical fiber expendable temperature/depth sensor based on the FBG-LPG cascaded structure is proposed to solve the problems of the CXBT, namely the use of LPG and FBG were used to detect the water temperature and depth, respectively. Secondly, the fiber end reflective mirror is used to simplify optical cascade structure and optimize the system performance. Finally, the optical path is designed and optimized using the reflective optical fiber end mirror. The experimental results show that the sensitivity of temperature and depth sensing based on FBG-LPG cascade structure is about 0.0030C and 0.1%F.S. respectively, which can meet the requirements of the sea water temperature/depth observation. The reflectivity of reflection mirror is in the range from 48.8% to 72.5%, the resonant peak of FBG and LPG are reasonable and the whole spectrum are suitable for demodulation. Through research on the optical fiber XBT (FXBT), the direct measurement of deep-sea temperature/depth profile data can be obtained simultaneously, quickly and accurately. The FXBT is a new all-optical seawater temperature/depth sensor, which has important academic value and broad application prospect and is expected to replace the CXBT in the future.

  16. Sampling strategies to improve passive optical remote sensing of river bathymetry

    Science.gov (United States)

    Legleiter, Carl; Overstreet, Brandon; Kinzel, Paul J.

    2018-01-01

    Passive optical remote sensing of river bathymetry involves establishing a relation between depth and reflectance that can be applied throughout an image to produce a depth map. Building upon the Optimal Band Ratio Analysis (OBRA) framework, we introduce sampling strategies for constructing calibration data sets that lead to strong relationships between an image-derived quantity and depth across a range of depths. Progressively excluding observations that exceed a series of cutoff depths from the calibration process improved the accuracy of depth estimates and allowed the maximum detectable depth ($d_{max}$) to be inferred directly from an image. Depth retrieval in two distinct rivers also was enhanced by a stratified version of OBRA that partitions field measurements into a series of depth bins to avoid biases associated with under-representation of shallow areas in typical field data sets. In the shallower, clearer of the two rivers, including the deepest field observations in the calibration data set did not compromise depth retrieval accuracy, suggesting that $d_{max}$ was not exceeded and the reach could be mapped without gaps. Conversely, in the deeper and more turbid stream, progressive truncation of input depths yielded a plausible estimate of $d_{max}$ consistent with theoretical calculations based on field measurements of light attenuation by the water column. This result implied that the entire channel, including pools, could not be mapped remotely. However, truncation improved the accuracy of depth estimates in areas shallower than $d_{max}$, which comprise the majority of the channel and are of primary interest for many habitat-oriented applications.

  17. Analytical probabilistic proton dose calculation and range uncertainties

    Science.gov (United States)

    Bangert, M.; Hennig, P.; Oelfke, U.

    2014-03-01

    We introduce the concept of analytical probabilistic modeling (APM) to calculate the mean and the standard deviation of intensity-modulated proton dose distributions under the influence of range uncertainties in closed form. For APM, range uncertainties are modeled with a multivariate Normal distribution p(z) over the radiological depths z. A pencil beam algorithm that parameterizes the proton depth dose d(z) with a weighted superposition of ten Gaussians is used. Hence, the integrals ∫ dz p(z) d(z) and ∫ dz p(z) d(z)2 required for the calculation of the expected value and standard deviation of the dose remain analytically tractable and can be efficiently evaluated. The means μk, widths δk, and weights ωk of the Gaussian components parameterizing the depth dose curves are found with least squares fits for all available proton ranges. We observe less than 0.3% average deviation of the Gaussian parameterizations from the original proton depth dose curves. Consequently, APM yields high accuracy estimates for the expected value and standard deviation of intensity-modulated proton dose distributions for two dimensional test cases. APM can accommodate arbitrary correlation models and account for the different nature of random and systematic errors in fractionated radiation therapy. Beneficial applications of APM in robust planning are feasible.

  18. Extraordinary tunable dynamic range of electrochemical aptasensor for accurate detection of ochratoxin A in food samples

    Directory of Open Access Journals (Sweden)

    Lin Cheng

    2017-06-01

    Full Text Available We report the design of a sensitive, electrochemical aptasensor for detection of ochratoxin A (OTA with an extraordinary tunable dynamic sensing range. This electrochemical aptasensor is constructed based on the target induced aptamer-folding detection mechanism and the recognition between OTA and its aptamers results in the conformational change of the aptamer probe and thus signal changes for measurement. The dynamic sensing range of the electrochemical aptasensor is successfully tuned by introduction of free assistant aptamer probes in the sensing system. Our electrochemical aptasensor shows an extraordinary dynamic sensing range of 11-order magnitude of OTA concentration from 10−8 to 102 ng/g. Of great significance, the signal response in all OTA concentration ranges is at the same current scale, demonstrating that our sensing protocol in this research could be applied for accurate detections of OTA in a broad range without using any complicated treatment of signal amplification. Finally, OTA spiked red wine and maize samples in different dynamic sensing ranges are determined with the electrochemical aptasensor under optimized sensing conditions. This tuning strategy of dynamic sensing range may offer a promising platform for electrochemical aptasensor optimizations in practical applications.

  19. Induction Thermography for Surface Crack Detection and Depth Determination

    Directory of Open Access Journals (Sweden)

    Beate Oswald-Tranta

    2018-02-01

    Full Text Available In the last few years, induction thermography has been established as a non-destructive testing method for localizing surface cracks in metals. The sample to be inspected is heated with a short induced electrical current pulse, and the infrared camera records—during and after the heating pulse—the temperature distribution at the surface. Transforming the temporal temperature development for each pixel to phase information makes not only highly reliable detection of the cracks possible but also allows an estimation of its depth. Finite element simulations were carried out to investigate how the phase contrast depends on parameters such as excitation frequency, pulse duration, material parameters, crack depth, and inclination angle of the crack. From these results, generalized functions for the dependency of the phase difference on all these parameters were derived. These functions can be used as an excellent guideline as to how measurement parameters should be optimized for a given material to be able to detect cracks and estimate their depth. Several experiments on different samples were also carried out, and the results compared with the simulations showed very good agreement.

  20. An Exploration of the Needling Depth in Acupuncture: The Safe Needling Depth and the Needling Depth of Clinical Efficacy

    Directory of Open Access Journals (Sweden)

    Jaung-Geng Lin

    2013-01-01

    Full Text Available Objective. To explore the existing scientific information regarding safe needling depth of acupuncture points and the needling depth of clinical efficacy. Methods. We searched the PubMed, EMBASE, Cochrane, Allied and Complementary Medicine (AMED, The National Center for Complementary and Alternative Medicine (NCCAM, and China National Knowledge Infrastructure (CNKI databases to identify relevant monographs and related references from 1991 to 2013. Chinese journals and theses/dissertations were hand searched. Results. 47 studies were recruited and divided into 6 groups by measuring tools, that is, MRI, in vivo evaluation, CT, ultrasound, dissected specimen of cadavers, and another group with clinical efficacy. Each research was analyzed for study design, definition of safe depth, and factors that would affect the measured depths. Depths of clinical efficacy were discussed from the perspective of de-qi and other clinical observations. Conclusions. Great inconsistency in depth of each point measured from different subject groups and tools exists. The definition of safe depth should be established through standardization. There is also lack of researches to compare the clinical efficacy. A well-designed clinical trial selecting proper measuring tools to decide the actual and advisable needling depth for each point, to avoid adverse effects or complications and promote optimal clinical efficacy, is a top priority.

  1. Experimental evidence concerning the significant information depth of electron backscatter diffraction (EBSD)

    Energy Technology Data Exchange (ETDEWEB)

    Wisniewski, Wolfgang, E-mail: wolfgang.w@uni-jena.de [Otto-Schott-Institut, Jena University, Fraunhoferstr. 6, 07743 Jena (Germany); Saager, Stefan [Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, Winterbergstraße 28, 01277 Dresden (Germany); Böbenroth, Andrea [Fraunhofer Institute for the Microstructure of Materials and Systems IMWS, Walter-Huelse-Straße 1, 06120 Halle (Saale) (Germany); Rüssel, Christian [Otto-Schott-Institut, Jena University, Fraunhoferstr. 6, 07743 Jena (Germany)

    2017-02-15

    Experiments concerning the information depth of electron backscatter diffraction (EBSD) are performed on samples featuring an amorphous wedge on a crystalline substrate and a crystalline wedge on an amorphous substrate. The effects of the acceleration voltage and exemplary software settings on the ability to measure through an amorphous layer are presented. Changes in the EBSD-signal could be detected through a ≈142 nm thick layer of amorphous Si while orientation measurements could be performed through a ≈116 nm thick layer when using a voltage of 30 kV. The complexity of the information depth significant to a given EBSD-pattern and the multiple parameters influencing it are discussed. It is suggested that a “core information depth” is significant to high quality patterns while a larger “maximum information depth” becomes relevant when the pattern quality decreases or the sample is inhomogeneous within the information volume, i.e. in the form of partially crystalline materials or crystal layers in the nm scale. - Highlights: • Experimental evidence of the significant information depth of EBSD is presented. • Effects of the voltage and exemplary software settings are discussed. • Dependence of the significant information depth on the pattern quality is proposed. • The information depth may reach up to 142 nm in Si when using a voltage of 30 kV. • The information depth depends on the available technology.

  2. A small and compact AMS facility for tritium depth profiling

    Indian Academy of Sciences (India)

    Depth profiling measurements of tritium in carbon samples have been performed during the past seven years at the AMS facility installed at the Rossendorf 3 MV Tandetron. The samples have been cut from the inner walls of the fusion experiments ASDEX-upgrade/Garching and JET/Culham. The tritium content of the ...

  3. Depth of Formation of Ferropericlase Included in Super-Deep Diamonds

    Science.gov (United States)

    Anzolini, C.; Nestola, F.; Gianese, A.; Nimis, P.; Harris, J. W.

    2017-12-01

    Super-deep diamonds are believed to have formed at depths of at least 300 km depth (Harte, 2010). A common mineral inclusion in these diamonds is ferropericlase, (Mg,Fe)O (see Kaminsky, 2012 and references therein). Ferropericlase (fPer) is the second most abundant mineral in the lower mantle, comprising approximately 16-20 wt% (660 to 2900 km depth), and inclusions of fPer in diamond are often considered to indicate a lower-mantle origin (Harte et al., 1999). Samples from São Luiz/Juina, Brazil, are noteworthy for containing nanometer-sized magnesioferrite (Harte et al., 1999; Wirth et al., 2014; Kaminsky et al., 2015; Palot et al., 2016). Based upon a phase diagram valid for 1 atm, such exsolutions would place the origin of this assemblage in the uppermost part of the lower mantle. However, a newly reported phase diagram for magnesioferrite demonstrates that the latter is not stable at such pressures and, thus, it cannot exsolve directly from fPer at lower-mantle conditions (Uenver-Thiele et al., 2017). Here we report the investigation of two fPer inclusions, extracted from a single São Luiz diamond, by single-crystal X-ray diffraction and field emission scanning electron microscopy. Both techniques showed micrometer-sized exsolutions of magnesioferrite within the two fPers. We also completed elastic geobarometry (see Angel et al., 2015), which determined an estimate for the depth of entrapment of the two ferropericlase - diamond pairs. In the temperature range between 1273 and 1773 K, pressures varied between 9.88 and 12.34 GPa (325-410 km depth) for one inclusion and between 10.69 and 13.16 GPa (350-440 km depth) for the other one. These results strengthen the hypothesis that solitary fPer inclusions might not be reliable markers for a lower-mantle provenance. This work was supported by Fondazione CaRiPaRo and ERC-2012-StG 307322 to FN. Angel, R.J., et al. (2015) Russ Geol Geophys, 56, 211-220; Harte, B. (2010) Mineral Mag, 74, 189-215; Harte, B., et al

  4. Diffusion of HTO, {sup 36}Cl{sup -}, {sup 125}I{sup -} and {sup 22}Na{sup +} in Opalinus Clay: Effect of Confining Pressure, Sample Orientation, Sample Depth and Temperature

    Energy Technology Data Exchange (ETDEWEB)

    Van Loon, L.R.; Soler, J.M

    2004-02-01

    Effective diffusion coefficients (D{sub e}), rock capacity factors ({alpha}) and diffusion-accessible porosities ({epsilon}) were measured using the through-diffusion technique. Transport (diffusion) was measured both perpendicular and parallel to the bedding. Special cells that allowed the application of an axial confining pressure were designed. The pressures applied ranged from 1 to 5 MPa for Mont Terri samples and between 4 and 15 MPa for Benken samples, the upper values representing the in-situ confining pressure at both locations. The test solutions used in the experiments were synthetic Opalinus Clay pore water, which has Na and Cl as main components (Mont Terri: I = 0.39 M; Benken: I = 0.20 M). Pressure only had a small effect on the value of the effective diffusion coefficients. In the case of Mont Terri samples, increasing the pressure from 1 to 5 MPa resulted in a decrease of the effective diffusion coefficient of 20% for HTO, 27% for {sup 36}Cl{sup -}, 29% for {sup 125}I{sup -} and 17 % for {sup 22}Na{sup +}. In the case of Benken samples, increasing the pressure from 4 to 15 MPa resulted in a decrease of D{sub e} of 17% for HTO, 22% for {sup 36}Cl{sup -}, 32% for {sup 125}I{sup -} and 17 % for {sup 22}Na{sup +}. Moreover, the effective diffusion coefficients for for {sup 36}Cl{sup -}are smaller than for HTO, which is consistent with an effect arising from anion exclusion. This ion exclusion effect is smaller in samples from Mont Terri than in samples from Benken, which can be explained by the higher ionic strength of the Mont Terri water used in the experiments. The diffusion of {sup 22}Na{sup +} is similar to that of HTO in the case of Mont Terri OPA. For Benken OPA, the D{sub e} value of {sup 22}Na{sup +} is a factor of 2 higher than that of HTO. This last observation cannot be explained so far but is comparable to experimental data from ANDRA (1999) on Callovo-Oxfordian claystones from the Meuse/Haute Same site. {sup 125}I{sup -} is retarded with

  5. Does footprint depth correlate with foot motion and pressure?

    Science.gov (United States)

    Bates, K T; Savage, R; Pataky, T C; Morse, S A; Webster, E; Falkingham, P L; Ren, L; Qian, Z; Collins, D; Bennett, M R; McClymont, J; Crompton, R H

    2013-06-06

    Footprints are the most direct source of evidence about locomotor biomechanics in extinct vertebrates. One of the principal suppositions underpinning biomechanical inferences is that footprint geometry correlates with dynamic foot pressure, which, in turn, is linked with overall limb motion of the trackmaker. In this study, we perform the first quantitative test of this long-standing assumption, using topological statistical analysis of plantar pressures and experimental and computer-simulated footprints. In computer-simulated footprints, the relative distribution of depth differed from the distribution of both peak and pressure impulse in all simulations. Analysis of footprint samples with common loading inputs and similar depths reveals that only shallow footprints lack significant topological differences between depth and pressure distributions. Topological comparison of plantar pressures and experimental beach footprints demonstrates that geometry is highly dependent on overall print depth; deeper footprints are characterized by greater relative forefoot, and particularly toe, depth than shallow footprints. The highlighted difference between 'shallow' and 'deep' footprints clearly emphasizes the need to understand variation in foot mechanics across different degrees of substrate compliance. Overall, our results indicate that extreme caution is required when applying the 'depth equals pressure' paradigm to hominin footprints, and by extension, those of other extant and extinct tetrapods.

  6. Depth distribution of benthic dinoflagellates in the Caribbean Sea

    Science.gov (United States)

    Boisnoir, Aurélie; Pascal, Pierre-Yves; Cordonnier, Sébastien; Lemée, Rodolophe

    2018-05-01

    Monitoring of benthic dinoflagellates is usually conducted between sub-surface and 5 m depth, where these organisms are supposed to be in highest abundances. However, only few studies have focused on the small-scale depth distribution of benthic dinoflagellates. In the present study, abundances of dinoflagellates were evaluated on an invasive macrophyte Halophila stipulacea in two coastal sites in Guadeloupe (Caribbean Sea) along a depth gradient from sub-surface to 3 m at Gosier and until 20 m at Rivière Sens during the tropical wet and dry seasons. Species of genus Ostreopsis and Prorocentrum were the most abundant. Depth did not influence total dinoflagellate abundance but several genera showed particular depth-distribution preferences. The highest abundances of Ostreopsis and Gambierdiscus species were estimated preferentially in surface waters, whereas Coolia spp. were found in the same proportions but in deeper waters. Halophila stipulacea biomass was positively correlated with Ostreopsis spp. abundance. Our study suggests that sampling of benthic dinoflagellates should be conducted at different water depths taking into account the presence of the macroalgal substrate as well. In the Caribbean area, special attention should be addressed to the presence of H. stipulacea which tends to homogenize the marine landscape and represents a substrate for hosting dinoflagellate growth.

  7. Depth profiling of extended defects in silicon by Rutherford backscattering measurements

    International Nuclear Information System (INIS)

    Gruska, B.; Goetz, G.

    1981-01-01

    Depth profiling of dislocations and stacking faults is carried out by analyzing axial and planar channeling data from As + -and P + -implanted silicon samples annealed at high temperatures. The analyzing procedure is based on the simple two-beam model. The results show that depth profiling of dislocations using planar channeling data is connected with a broadening of the real distributions. A degradation of the defect concentration and a deformation of the profile result for very high defect concentrations (> 5 x 10 5 cm/cm 2 ). All these effects can be neglected by analyzing axial channeling data. Depth profiling of stacking faults is restricted to the determination of the depth distribution of displaced atomic rows or planes. For both the procedures, axial as well as planar channeling measurements, the same depth profiles of displaced atomic rows are obtained. (author)

  8. Investigating the Scaling Properties of Extreme Rainfall Depth ...

    African Journals Online (AJOL)

    Investigating the Scaling Properties of Extreme Rainfall Depth Series in Oromia Regional State, Ethiopia. ... Science, Technology and Arts Research Journal ... for storm duration ranging from 0.5 to 24 hr observed at network of rain gauges sited in Oromia regional state were analyzed using an approach based on moments.

  9. An improved in situ method for determining depth distributions of gamma-ray emitting radionuclides

    International Nuclear Information System (INIS)

    Benke, R.R.; Kearfott, K.J.

    2001-01-01

    In situ gamma-ray spectrometry determines the quantities of radionuclides in some medium with a portable detector. The main limitation of in situ gamma-ray spectrometry lies in determining the depth distribution of radionuclides. This limitation is addressed by developing an improved in situ method for determining the depth distributions of gamma-ray emitting radionuclides in large area sources. This paper implements a unique collimator design with conventional radiation detection equipment. Cylindrically symmetric collimators were fabricated to allow only those gamma-rays emitted from a selected range of polar angles (measured off the detector axis) to be detected. Positioned with its axis normal to surface of the media, each collimator enables the detection of gamma-rays emitted from a different range of polar angles and preferential depths. Previous in situ methods require a priori knowledge of the depth distribution shape. However, the absolute method presented in this paper determines the depth distribution as a histogram and does not rely on such assumptions. Other advantages over previous in situ methods are that this method only requires a single gamma-ray emission, provides more detailed depth information, and offers a superior ability for characterizing complex depth distributions. Collimated spectrometer measurements of buried area sources demonstrated the ability of the method to yield accurate depth information. Based on the results of actual measurements, this method increases the potential of in situ gamma-ray spectrometry as an independent characterization tool in situations with unknown radionuclide depth distributions

  10. Techniques for estimating flood-depth frequency relations for streams in West Virginia

    Science.gov (United States)

    Wiley, J.B.

    1987-01-01

    Multiple regression analyses are applied to data from 119 U.S. Geological Survey streamflow stations to develop equations that estimate baseline depth (depth of 50% flow duration) and 100-yr flood depth on unregulated streams in West Virginia. Drainage basin characteristics determined from the 100-yr flood depth analysis were used to develop 2-, 10-, 25-, 50-, and 500-yr regional flood depth equations. Two regions with distinct baseline depth equations and three regions with distinct flood depth equations are delineated. Drainage area is the most significant independent variable found in the central and northern areas of the state where mean basin elevation also is significant. The equations are applicable to any unregulated site in West Virginia where values of independent variables are within the range evaluated for the region. Examples of inapplicable sites include those in reaches below dams, within and directly upstream from bridge or culvert constrictions, within encroached reaches, in karst areas, and where streams flow through lakes or swamps. (Author 's abstract)

  11. Mesophotic coral depth acclimatization is a function of host-specific symbiont physiology

    KAUST Repository

    Ziegler, Maren

    2015-02-06

    Mesophotic coral ecosystems receive increasing attention owing to their potential as deep coral refuges in times of global environmental change. Here, the mechanisms of coral holobiont photoacclimatization over a 60 m depth gradient in the central Red Sea were examined for the four coral genera Porites, Leptoseris, Pachyseris, and Podabacia. General acclimatization strategies were common to all host-symbiont combinations, e.g., Symbiodinium cell densities and photoprotective (PP) to light-harvesting pigment ratios both significantly decreased with water depth. Porites harbored Symbiodinium type C15 over the whole 60 m depth range, while Pachyseris and Podabacia had limited vertical distributions and hosted mainly Symbiodinium type C1. Symbiodinium type C15 had generally higher xanthophyll de-epoxidation rates and lower maximum quantum yields than C1, and also exhibited a strong photoacclimatory signal over depth that relates to the large distribution range of Porites. Interestingly, the coral host had an effect on Symbiodinium pigment composition. When comparing Symbiodinium type C1 in Podabacia and Pachyseris, the ß-carotene chl a−1, the peridinin chl a−1, and diadinoxanthin chl a−1 ratios were significantly different between host species. Our data support a view that depth acclimatization of corals in the mesophotics is facilitated by Symbiodinium physiology, which in turn is host-specific.

  12. Mesophotic coral depth acclimatization is a function of host-specific symbiont physiology

    KAUST Repository

    Ziegler, Maren; Roder, Cornelia; Bü chel, Claudia; Voolstra, Christian R.

    2015-01-01

    Mesophotic coral ecosystems receive increasing attention owing to their potential as deep coral refuges in times of global environmental change. Here, the mechanisms of coral holobiont photoacclimatization over a 60 m depth gradient in the central Red Sea were examined for the four coral genera Porites, Leptoseris, Pachyseris, and Podabacia. General acclimatization strategies were common to all host-symbiont combinations, e.g., Symbiodinium cell densities and photoprotective (PP) to light-harvesting pigment ratios both significantly decreased with water depth. Porites harbored Symbiodinium type C15 over the whole 60 m depth range, while Pachyseris and Podabacia had limited vertical distributions and hosted mainly Symbiodinium type C1. Symbiodinium type C15 had generally higher xanthophyll de-epoxidation rates and lower maximum quantum yields than C1, and also exhibited a strong photoacclimatory signal over depth that relates to the large distribution range of Porites. Interestingly, the coral host had an effect on Symbiodinium pigment composition. When comparing Symbiodinium type C1 in Podabacia and Pachyseris, the ß-carotene chl a−1, the peridinin chl a−1, and diadinoxanthin chl a−1 ratios were significantly different between host species. Our data support a view that depth acclimatization of corals in the mesophotics is facilitated by Symbiodinium physiology, which in turn is host-specific.

  13. Three-finger tracheal palpation to guide endotracheal tube depth in children.

    Science.gov (United States)

    Gamble, Jonathan J; McKay, William P; Wang, Andrew F; Yip, Kinsha A; O'Brien, Jennifer M; Plewes, Christopher E

    2014-10-01

    Accurate endotracheal tube (ETT) depth is critical, especially in children. The current tools used to guide appropriate ETT depth have significant limitations. To evaluate the utility of tracheal palpation in the neck to guide appropriate ETT placement in children. A prospective observational study with a convenience sample of 50 children was conducted. During intubation, an investigator palpated the trachea with three fingertips side-by-side extending upward from the suprasternal notch. The anesthesiologist advanced the ETT slowly until palpated at the sternal notch. The investigator stated ETT palpation certainty as 'strongly felt', 'weakly felt', or 'not felt.' Final ETT position was determined by bronchoscopy and categorized as 'ETT too shallow' (tip in proximal ¼ of trachea), 'ETT too deep' (tip in distal ¼ of trachea), or 'ETT placement satisfactory' (between those extremes). Thirty boys and 20 girls undergoing dental surgery with nasal intubation were recruited (median age 4.4 years; range 2.0-10.8). The ETT (all ≥4 mm ID) was palpable at the sternal notch in all patients: 46 of 50 strongly palpable and 4 of 50 weakly palpable. The experimental methods led to satisfactory ETT placement in 49 of 50 patients, too deep in 1 of 50 patients. Compared with the Pediatrics Advanced Life Support (PALS) predictive formula, satisfactory placement would have been 41 of 50 patients (P guide ETT placement has excellent clinical performance and better guides appropriate ETT depth than the PALS formula in our study population. © 2014 John Wiley & Sons Ltd.

  14. Depth dependent local structures in CoPt thin films

    Energy Technology Data Exchange (ETDEWEB)

    Souza-Neto, N M [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Ramos, A Y; Tolentino, H C N; Joly, Y, E-mail: aline.ramos@grenoble.cnrs.f [Institut Neel, CNRS et Univ. Joseph Fourier, BP 166, F-38042 Grenoble Cedex 9 (France)

    2009-11-15

    X-ray absorption spectroscopy (XAS) has been used to clarify the thickness-dependent magnetic properties in nanometric CoPt films. We get benefit from the variation of the sampling depth with the grazing angle to investigate the variations of the local order within the film. In order to properly reconstruct the 3D information the experiments were performed either in the in-plane as in the out-of-plane geometries and supported by ab initio calculations. A depth dependence in the chemical order is revealed and the magnetic behavior is interpreted within this framework.

  15. Tritium depth profiling in carbon by accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Friedrich, M.; Pilz, W.; Sun, G.; Behrisch, R.; Garcia-Rosales, C.; Bekris, N.; Penzhorn, R.-D.

    2000-01-01

    Tritium depth profiling measurements by accelerator mass spectrometry have been performed at the facility installed at the Rossendorf 3 MV Tandetron. In order to achieve a uniform erosion at the target surface inside a commercial Cs ion sputtering source and to avoid edge effects, the samples were mechanically scanned and the signals were recorded only during sputtering at the centre of the sputtered area. The sputtered negative ions were mass analysed by the injection magnet of the Tandetron. Hydrogen and deuterium profiles were measured with the Faraday cup between the injection magnet and the accelerator, while the tritium was counted after the accelerator with semiconductor detectors. Depth profiles have been measured for carbon samples which had been exposed to the plasma at the first wall of the Garching fusion experiment ASDEX-Upgrade and from the European fusion experiment JET, Culham, UK

  16. Simultaneous reconstruction of multiple depth images without off-focus points in integral imaging using a graphics processing unit.

    Science.gov (United States)

    Yi, Faliu; Lee, Jieun; Moon, Inkyu

    2014-05-01

    The reconstruction of multiple depth images with a ray back-propagation algorithm in three-dimensional (3D) computational integral imaging is computationally burdensome. Further, a reconstructed depth image consists of a focus and an off-focus area. Focus areas are 3D points on the surface of an object that are located at the reconstructed depth, while off-focus areas include 3D points in free-space that do not belong to any object surface in 3D space. Generally, without being removed, the presence of an off-focus area would adversely affect the high-level analysis of a 3D object, including its classification, recognition, and tracking. Here, we use a graphics processing unit (GPU) that supports parallel processing with multiple processors to simultaneously reconstruct multiple depth images using a lookup table containing the shifted values along the x and y directions for each elemental image in a given depth range. Moreover, each 3D point on a depth image can be measured by analyzing its statistical variance with its corresponding samples, which are captured by the two-dimensional (2D) elemental images. These statistical variances can be used to classify depth image pixels as either focus or off-focus points. At this stage, the measurement of focus and off-focus points in multiple depth images is also implemented in parallel on a GPU. Our proposed method is conducted based on the assumption that there is no occlusion of the 3D object during the capture stage of the integral imaging process. Experimental results have demonstrated that this method is capable of removing off-focus points in the reconstructed depth image. The results also showed that using a GPU to remove the off-focus points could greatly improve the overall computational speed compared with using a CPU.

  17. Measurement of underground water-soil radioactivity at different depths in arsenic prone areas

    International Nuclear Information System (INIS)

    Ghosh, D.; Deb, A.; Patra, K.K.; Sengupta, R.; Nag, S.K.

    2007-01-01

    Studies on the presence of alpha emitting nuclides in the environment assume importance since they are found to be carcinogenic. Measurement of radioactivity in arsenic contaminated drinking water has already been reported. To perform a detail study we have undertaken a programme to measure radioactivity in drinking water and soil samples in three different places of North 24 Parganas in West Bengal, India, where arsenic contamination is severe. A detail investigation on soil samples at different depths and soil-water samples at same depth have been made with CR-39 plates -a Solid State Nuclear Track Detector (SSNTD) -a commonly used detector for alpha radiation. The data indicates high alpha activity in soil than water and this ratio is different at different places varying from 1.22 to 2.63. The dependence of the alpha activity in soil on depth is also different at different sites. The data shows some interesting results. (author)

  18. Real-time depth monitoring and control of laser machining through scanning beam delivery system

    International Nuclear Information System (INIS)

    Ji, Yang; Grindal, Alexander W; Fraser, James M; Webster, Paul J L

    2015-01-01

    Scanning optics enable many laser applications in manufacturing because their low inertia allows rapid movement of the process beam across the sample. We describe our method of inline coherent imaging for real-time (up to 230 kHz) micron-scale (7–8 µm axial resolution) tracking and control of laser machining depth through a scanning galvo-telecentric beam delivery system. For 1 cm trench etching in stainless steel, we collect high speed intrapulse and interpulse morphology which is useful for further understanding underlying mechanisms or comparison with numerical models. We also collect overall sweep-to-sweep depth penetration which can be used for feedback depth control. For trench etching in silicon, we show the relationship of etch rate with average power and scan speed by computer processing of depth information without destructive sample post-processing. We also achieve three-dimensional infrared continuous wave (modulated) laser machining of a 3.96 × 3.96 × 0.5 mm 3 (length × width × maximum depth) pattern on steel with depth feedback. To the best of our knowledge, this is the first successful demonstration of direct real-time depth monitoring and control of laser machining with scanning optics. (paper)

  19. Global field synchronization in gamma range of the sleep EEG tracks sleep depth: Artifact introduced by a rectangular analysis window.

    Science.gov (United States)

    Rusterholz, Thomas; Achermann, Peter; Dürr, Roland; Koenig, Thomas; Tarokh, Leila

    2017-06-01

    Investigating functional connectivity between brain networks has become an area of interest in neuroscience. Several methods for investigating connectivity have recently been developed, however, these techniques need to be applied with care. We demonstrate that global field synchronization (GFS), a global measure of phase alignment in the EEG as a function of frequency, must be applied considering signal processing principles in order to yield valid results. Multichannel EEG (27 derivations) was analyzed for GFS based on the complex spectrum derived by the fast Fourier transform (FFT). We examined the effect of window functions on GFS, in particular of non-rectangular windows. Applying a rectangular window when calculating the FFT revealed high GFS values for high frequencies (>15Hz) that were highly correlated (r=0.9) with spectral power in the lower frequency range (0.75-4.5Hz) and tracked the depth of sleep. This turned out to be spurious synchronization. With a non-rectangular window (Tukey or Hanning window) these high frequency synchronization vanished. Both, GFS and power density spectra significantly differed for rectangular and non-rectangular windows. Previous papers using GFS typically did not specify the applied window and may have used a rectangular window function. However, the demonstrated impact of the window function raises the question of the validity of some previous findings at higher frequencies. We demonstrated that it is crucial to apply an appropriate window function for determining synchronization measures based on a spectral approach to avoid spurious synchronization in the beta/gamma range. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Investigating the depth of thermal burns in elephants

    Directory of Open Access Journals (Sweden)

    A. Shakespeare

    2006-06-01

    Full Text Available Histological examination of burn injuries in elephants revealed that the depth was not as severe as expected from clinical observation. Although the actual burn depth was deep, the thickness of elephant skin, especially the dermis, resulted in the lesions being classified as less severe than expected. Examination of skin samples from selected areas showed that most lesions were either superficial (1st degree or superficial partial-thickness (superficial 2nd degree burns with the occasional deep partial thickness (deep 2nd degree wound. These lesions however, resulted in severe complications that eventually led to the death of a number of the elephants.

  1. Stronger at Depth: Jamming Grippers as Deep Sea Sampling Tools.

    Science.gov (United States)

    Licht, Stephen; Collins, Everett; Mendes, Manuel Lopes; Baxter, Christopher

    2017-12-01

    In this work we experimentally demonstrate (a) that the holding strength of universal jamming grippers increases as a function of the jamming pressure to greater than three atmospheres, and (b) that jamming grippers can be operated in the deep sea in ambient pressures exceeding one hundred atmospheres, where such high jamming pressures can be readily achieved. Laboratory experiments in a pressurized, water-filled test cell are used to measure the holding force of a "universal" style jamming gripper as a function of the pressure difference between internal membrane pressure and ambient pressure. Experiments at sea are used to demonstrate that jamming grippers can be installed on, and operated from, remotely operated vehicles at depths in excess of 1200 m. In both experiments, the jamming gripper consists of a latex balloon filled with a mixture of fresh water and ∼200 μm glass beads, which are cheaply available in large quantities as sand blasting media. The use of a liquid, rather than a gas, as the fluid media allows operation of the gripper with a closed-loop fluid system; jamming pressure is controlled with an electrically driven water hydraulic cylinder in the laboratory and with an oil hydraulic-driven large-bore water hydraulic cylinder at sea.

  2. Weighted halfspace depth

    Czech Academy of Sciences Publication Activity Database

    Kotík, Lukáš; Hlubinka, D.; Vencálek, O.

    Vol. 46, č. 1 (2010), s. 125-148 ISSN 0023-5954 Institutional research plan: CEZ:AV0Z10750506 Keywords : data depth * nonparametric multivariate analysis * strong consistency of depth * mixture of distributions Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.461, year: 2010 http://library.utia.cas.cz/separaty/2010/SI/kotik-weighted halfspace depth.pdf

  3. Effect of lapping slurry on critical cutting depth of spinel

    International Nuclear Information System (INIS)

    Wang, Zhan-kui; Wang, Zhuan-kui; Zhu, Yong-wei; Su, Jian-xiu

    2015-01-01

    Highlights: • Measured spinel wafers’ hardness and crack length in different slurries. • Evaluated the softened layer thickness in different slurries. • Discussed the effect of slurries on critical cutting depth of spinel. - Abstract: The critical cutting depth for lapping process is very important because it influences the mode of material removal. In this paper, a serial of microscopic indentation experiments were carried out for measuring spinel wafers’ hardness and crack length in different lapping slurries. Their critical cutting depth and fracture toughness were calculated. X-ray photoelectron spectroscopy (XPS) was also employed to study the surface chemical composition and softened layer thickness of wafers in different slurries. Experimental results indicate that the softened layers of spinel wafers are formed due to the corrosion of lapping slurries, which leads to a lower hardness and a larger fracture toughness of samples, and increases the critical cutting depth. Among them, the critical cutting depth in ethylene glycol solution is the largest and up to 21.8 nm. The increase of critical cutting depth is helpful to modify the surface quality of the work-piece being lapped via ductile removal mode instead of brittle fracture mode

  4. Human machine interface by using stereo-based depth extraction

    Science.gov (United States)

    Liao, Chao-Kang; Wu, Chi-Hao; Lin, Hsueh-Yi; Chang, Ting-Ting; Lin, Tung-Yang; Huang, Po-Kuan

    2014-03-01

    The ongoing success of three-dimensional (3D) cinema fuels increasing efforts to spread the commercial success of 3D to new markets. The possibilities of a convincing 3D experience at home, such as three-dimensional television (3DTV), has generated a great deal of interest within the research and standardization community. A central issue for 3DTV is the creation and representation of 3D content. Acquiring scene depth information is a fundamental task in computer vision, yet complex and error-prone. Dedicated range sensors, such as the Time­ of-Flight camera (ToF), can simplify the scene depth capture process and overcome shortcomings of traditional solutions, such as active or passive stereo analysis. Admittedly, currently available ToF sensors deliver only a limited spatial resolution. However, sophisticated depth upscaling approaches use texture information to match depth and video resolution. At Electronic Imaging 2012 we proposed an upscaling routine based on error energy minimization, weighted with edge information from an accompanying video source. In this article we develop our algorithm further. By adding temporal consistency constraints to the upscaling process, we reduce disturbing depth jumps and flickering artifacts in the final 3DTV content. Temporal consistency in depth maps enhances the 3D experience, leading to a wider acceptance of 3D media content. More content in better quality can boost the commercial success of 3DTV.

  5. The maximum economic depth of groundwater abstraction for irrigation

    Science.gov (United States)

    Bierkens, M. F.; Van Beek, L. P.; de Graaf, I. E. M.; Gleeson, T. P.

    2017-12-01

    Over recent decades, groundwater has become increasingly important for agriculture. Irrigation accounts for 40% of the global food production and its importance is expected to grow further in the near future. Already, about 70% of the globally abstracted water is used for irrigation, and nearly half of that is pumped groundwater. In many irrigated areas where groundwater is the primary source of irrigation water, groundwater abstraction is larger than recharge and we see massive groundwater head decline in these areas. An important question then is: to what maximum depth can groundwater be pumped for it to be still economically recoverable? The objective of this study is therefore to create a global map of the maximum depth of economically recoverable groundwater when used for irrigation. The maximum economic depth is the maximum depth at which revenues are still larger than pumping costs or the maximum depth at which initial investments become too large compared to yearly revenues. To this end we set up a simple economic model where costs of well drilling and the energy costs of pumping, which are a function of well depth and static head depth respectively, are compared with the revenues obtained for the irrigated crops. Parameters for the cost sub-model are obtained from several US-based studies and applied to other countries based on GDP/capita as an index of labour costs. The revenue sub-model is based on gross irrigation water demand calculated with a global hydrological and water resources model, areal coverage of crop types from MIRCA2000 and FAO-based statistics on crop yield and market price. We applied our method to irrigated areas in the world overlying productive aquifers. Estimated maximum economic depths range between 50 and 500 m. Most important factors explaining the maximum economic depth are the dominant crop type in the area and whether or not initial investments in well infrastructure are limiting. In subsequent research, our estimates of

  6. A new macrofaunal limit in the deep biosphere revealed by extreme burrow depths in ancient sediments.

    Science.gov (United States)

    Cobain, S L; Hodgson, D M; Peakall, J; Wignall, P B; Cobain, M R D

    2018-01-10

    Macrofauna is known to inhabit the top few 10s cm of marine sediments, with rare burrows up to two metres below the seabed. Here, we provide evidence from deep-water Permian strata for a previously unrecognised habitat up to at least 8 metres below the sediment-water interface. Infaunal organisms exploited networks of forcibly injected sand below the seabed, forming living traces and reworking sediment. This is the first record that shows sediment injections are responsible for hosting macrofaunal life metres below the contemporaneous seabed. In addition, given the widespread occurrence of thick sandy successions that accumulate in deep-water settings, macrofauna living in the deep biosphere are likely much more prevalent than considered previously. These findings should influence future sampling strategies to better constrain the depth range of infaunal animals living in modern deep-sea sands. One Sentence Summary: The living depth of infaunal macrofauna is shown to reach at least 8 metres in new habitats associated with sand injections.

  7. Photothermal investigation of local and depth dependent magnetic properties

    International Nuclear Information System (INIS)

    Pelzl, J; Meckenstock, R

    2010-01-01

    To achieve a spatially resolved measurement of magnetic properties two different photothermal approaches are used which rely on heat dissipated by magnetic resonance absorption or thermal modulation of the magnetic properties, respectively. The heat produced by modulated microwave absorption is detected by the classical photothermal methods such as photoacoustic effect and mirage effect. Examples comprise depth resolution of the magnetization of layered tapes and visualisation of magnetic excitations in ferrites. The second photothermal technique relies on the local modulation of magnetic properties by a thermal wave generated with an intensity modulated laser beam incident on the sample. This technique has a higher spatial resolution and sensitivity and has been used to characterize lateral magnetic properties of multilayers and spintronic media. To extend the lateral resolution of the ferromagnetic resonance detection into the nm-range techniques have been developed which are based on the detection of the modulated thermal microwave response by the thermal probe of an atomic force microscope (AFM) or by detection the thermal expansion of the magnetic sample in the course of the resonant microwave absorption with an AFM or tunnelling microscope. These thermal near field based techniques in ferromagnetic resonance have been successfully applied to image magnetic inhomogeneities around nano-structures and to measure the ferromagnetic resonance from magnetic nano-dots.

  8. Depth enhancement of S3D content and the psychological effects

    Science.gov (United States)

    Hirahara, Masahiro; Shiraishi, Saki; Kawai, Takashi

    2012-03-01

    Stereoscopic 3D (S3D) imaging technologies are widely used recently to create content for movies, TV programs, games, etc. Although S3D content differs from 2D content by the use of binocular parallax to induce depth sensation, the relationship between depth control and the user experience remains unclear. In this study, the user experience was subjectively and objectively evaluated in order to determine the effectiveness of depth control, such as an expansion or reduction or a forward or backward shift in the range of maximum parallactic angles in the cross and uncross directions (depth bracket). Four types of S3D content were used in the subjective and objective evaluations. The depth brackets of comparison stimuli were modified in order to enhance the depth sensation corresponding to the content. Interpretation Based Quality (IBQ) methodology was used for the subjective evaluation and the heart rate was measured to evaluate the physiological effect. The results of the evaluations suggest the following two points. (1) Expansion/reduction of the depth bracket affects preference and enhances positive emotions to the S3D content. (2) Expansion/reduction of the depth bracket produces above-mentioned effects more notable than shifting the cross/uncross directions.

  9. Electron beam absorption in solid and in water phantoms: depth scaling and energy-range relations

    International Nuclear Information System (INIS)

    Grosswendt, B.; Roos, M.

    1989-01-01

    In electron dosimetry energy parameters are used with values evaluated from ranges in water. The electron ranges in water may be deduced from ranges measured in solid phantoms. Several procedures recommended by national and international organisations differ both in the scaling of the ranges and in the energy-range relations for water. Using the Monte Carlo method the application of different procedures for electron energies below 10 MeV is studied for different phantom materials. It is shown that deviations in the range scaling and in the energy-range relations for water may accumulate to give energy errors of several per cent. In consequence energy-range relations are deduced for several solid phantom materials which enable a single-step energy determination. (author)

  10. The matter power spectrum from the Ly alpha forest : an optical depth estimate

    NARCIS (Netherlands)

    Zaroubi, S; Nusser, A; Haehnelt, M; Kim, TS; Viel, M.

    2006-01-01

    We measure the matter power spectrum from 31 Ly alpha spectra spanning the redshift range of 1.6-3.6. The optical depth, tau, for Ly alpha absorption of the intergalactic medium is obtained from the flux using the inversion method of Nusser & Haehnelt. The optical depth is converted to density by

  11. Multi-approach analysis of maximum riverbed scour depth above subway tunnel

    OpenAIRE

    Jun Chen; Hong-wu Tang; Zui-sen Li; Wen-hong Dai

    2010-01-01

    When subway tunnels are routed underneath rivers, riverbed scour may expose the structure, with potentially severe consequences. Thus, it is important to identify the maximum scour depth to ensure that the designed buried depth is adequate. There are a range of methods that may be applied to this problem, including the fluvial process analysis method, geological structure analysis method, scour formula method, scour model experiment method, and numerical simulation method. However, the applic...

  12. Focal depth measurement of scanning helium ion microscope

    International Nuclear Information System (INIS)

    Guo, Hongxuan; Itoh, Hiroshi; Wang, Chunmei; Zhang, Han; Fujita, Daisuke

    2014-01-01

    When facing the challenges of critical dimension measurement of complicated nanostructures, such as of the three dimension integrated circuit, characterization of the focal depth of microscopes is important. In this Letter, we developed a method for characterizing the focal depth of a scanning helium ion microscope (HIM) by using an atomic force microscope tip characterizer (ATC). The ATC was tilted in a sample chamber at an angle to the scanning plan. Secondary electron images (SEIs) were obtained at different positions of the ATC. The edge resolution of the SEIs shows the nominal diameters of the helium ion beam at different focal levels. With this method, the nominal shapes of the helium ion beams were obtained with different apertures. Our results show that a small aperture is necessary to get a high spatial resolution and high depth of field images with HIM. This work provides a method for characterizing and improving the performance of HIM.

  13. Automated combustion accelerator mass spectrometry for the analysis of biomedical samples in the low attomole range.

    Science.gov (United States)

    van Duijn, Esther; Sandman, Hugo; Grossouw, Dimitri; Mocking, Johannes A J; Coulier, Leon; Vaes, Wouter H J

    2014-08-05

    The increasing role of accelerator mass spectrometry (AMS) in biomedical research necessitates modernization of the traditional sample handling process. AMS was originally developed and used for carbon dating, therefore focusing on a very high precision but with a comparably low sample throughput. Here, we describe the combination of automated sample combustion with an elemental analyzer (EA) online coupled to an AMS via a dedicated interface. This setup allows direct radiocarbon measurements for over 70 samples daily by AMS. No sample processing is required apart from the pipetting of the sample into a tin foil cup, which is placed in the carousel of the EA. In our system, up to 200 AMS analyses are performed automatically without the need for manual interventions. We present results on the direct total (14)C count measurements in <2 μL human plasma samples. The method shows linearity over a range of 0.65-821 mBq/mL, with a lower limit of quantification of 0.65 mBq/mL (corresponding to 0.67 amol for acetaminophen). At these extremely low levels of activity, it becomes important to quantify plasma specific carbon percentages. This carbon percentage is automatically generated upon combustion of a sample on the EA. Apparent advantages of the present approach include complete omission of sample preparation (reduced hands-on time) and fully automated sample analysis. These improvements clearly stimulate the standard incorporation of microtracer research in the drug development process. In combination with the particularly low sample volumes required and extreme sensitivity, AMS strongly improves its position as a bioanalysis method.

  14. Electric field depth-focality tradeoff in transcranial magnetic stimulation: simulation comparison of 50 coil designs.

    Science.gov (United States)

    Deng, Zhi-De; Lisanby, Sarah H; Peterchev, Angel V

    2013-01-01

    Various transcranial magnetic stimulation (TMS) coil designs are available or have been proposed. However, key coil characteristics such as electric field focality and attenuation in depth have not been adequately compared. Knowledge of the coil focality and depth characteristics can help TMS researchers and clinicians with coil selection and interpretation of TMS studies. To quantify the electric field focality and depth of penetration of various TMS coils. The electric field distributions induced by 50 TMS coils were simulated in a spherical human head model using the finite element method. For each coil design, we quantified the electric field penetration by the half-value depth, d(1/2), and focality by the tangential spread, S(1/2), defined as the half-value volume (V(1/2)) divided by the half-value depth, S(1/2) = V(1/2)/d(1/2). The 50 TMS coils exhibit a wide range of electric field focality and depth, but all followed a depth-focality tradeoff: coils with larger half-value depth cannot be as focal as more superficial coils. The ranges of achievable d(1/2) are similar between coils producing circular and figure-8 electric field patterns, ranging 1.0-3.5 cm and 0.9-3.4 cm, respectively. However, figure-8 field coils are more focal, having S(1/2) as low as 5 cm(2) compared to 34 cm(2) for circular field coils. For any coil design, the ability to directly stimulate deeper brain structures is obtained at the expense of inducing wider electrical field spread. Novel coil designs should be benchmarked against comparison coils with consistent metrics such as d(1/2) and S(1/2). Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Improving Focal Depth Estimates: Studies of Depth Phase Detection at Regional Distances

    Science.gov (United States)

    Stroujkova, A.; Reiter, D. T.; Shumway, R. H.

    2006-12-01

    The accurate estimation of the depth of small, regionally recorded events continues to be an important and difficult explosion monitoring research problem. Depth phases (free surface reflections) are the primary tool that seismologists use to constrain the depth of a seismic event. When depth phases from an event are detected, an accurate source depth is easily found by using the delay times of the depth phases relative to the P wave and a velocity profile near the source. Cepstral techniques, including cepstral F-statistics, represent a class of methods designed for the depth-phase detection and identification; however, they offer only a moderate level of success at epicentral distances less than 15°. This is due to complexities in the Pn coda, which can lead to numerous false detections in addition to the true phase detection. Therefore, cepstral methods cannot be used independently to reliably identify depth phases. Other evidence, such as apparent velocities, amplitudes and frequency content, must be used to confirm whether the phase is truly a depth phase. In this study we used a variety of array methods to estimate apparent phase velocities and arrival azimuths, including beam-forming, semblance analysis, MUltiple SIgnal Classification (MUSIC) (e.g., Schmidt, 1979), and cross-correlation (e.g., Cansi, 1995; Tibuleac and Herrin, 1997). To facilitate the processing and comparison of results, we developed a MATLAB-based processing tool, which allows application of all of these techniques (i.e., augmented cepstral processing) in a single environment. The main objective of this research was to combine the results of three focal-depth estimation techniques and their associated standard errors into a statistically valid unified depth estimate. The three techniques include: 1. Direct focal depth estimate from the depth-phase arrival times picked via augmented cepstral processing. 2. Hypocenter location from direct and surface-reflected arrivals observed on sparse

  16. Rapid change with depth in megabenthic structure-forming communities of the Makapu'u deep-sea coral bed

    Science.gov (United States)

    Long, Dustin J.; Baco, Amy R.

    2014-01-01

    Seamounts are largely unexplored undersea mountains rising abruptly from the ocean floor, which can support an increased abundance and diversity of organisms. Deep-sea corals are important benthic structure-formers on current-swept hard substrates in these habitats. While depth is emerging as a factor structuring the fauna of seamounts on a large spatial scale, most work addressing deep-sea coral and seamount community structure has not considered the role of small-scale variation in species distributions. Video from six ROV dives over a depth range of ~320-530 m were analyzed to assess the diversity and density of benthic megafaunal invertebrates across the Makapu'u deep-sea coral bed, offshore of Oahu, Hawaii. At the same time, the physical environment along the dive track was surveyed to relate biotic patterns with abiotic variables including depth, aspect, rugosity, substrate, slope and relief to test the factors structuring community assemblages. Despite the narrow range examined, depth was found to be the strongest structuring gradient, and six unique macrobenthic communities were found, with a 93% faunal dissimilarity over the depth surveyed. Relief, rugosity and slope were also factors in the final model. Alcyonacean octocorals were the dominant macrofaunal invertebrates at all but the deepest depth zone. The commercially harvested precious coral C. secundum was the dominant species at depths 370-470 m, with a distribution that is on average deeper than similar areas. This may be artificial due to the past harvesting of this species on the shallower portion of its range. Primnoid octocorals were the most abundant octocoral family overall. This work yields new insight on the spatial ecology of seamounts, pointing out that community changes can occur over narrow depth ranges and that communities can be structured by small-scale physiography.

  17. Autonomous water sampling for long-term monitoring of trace metals in remote environments.

    Science.gov (United States)

    Kim, Hyojin; Bishop, James K B; Wood, Todd J; Fung, Inez Y

    2012-10-16

    A remotely controlled autonomous method for long-term high-frequency sampling of environmental waters in remote locations is described. The method which preserves sample integrity of dissolved trace metals and major ions for month-long periods employs a gravitational filtration system (GFS) that separates dissolved and particulate phases as samples are collected. The key elements of GFS are (1) a modified "air-outlet" filter holder to maximize filtration rate and thus minimize filtration artifacts; and (2) the direct delivery of filtrate to dedicated bottle sets for specific analytes. Depth and screen filter types were evaluated with depth filters showing best performance. GFS performance is validated using ground, stream, and estuary waters. Over 30 days of storage, samples with GFS treatment had average recoveries of 95 ± 19% and 105 ± 7% of Fe and Mn, respectively; without GFS treatment, average recoveries were only 16% and 18%. Dissolved major cations K, Mg, and Na were stable independent of collection methodology, whereas Ca in some groundwater samples decreased up to 42% without GFS due to CaCO(3) precipitation. In-field performance of GFS equipped autosamplers is demonstrated using ground and streamwater samples collected at the Angelo Coast Range Reserve, California from October 3 to November 4 2011.

  18. Prestack depth migration

    International Nuclear Information System (INIS)

    Postma, R.W.

    1991-01-01

    Two lines form the southern North Sea, with known velocity inhomogeneities in the overburden, have been pre-stack depth migrated. The pre-stack depth migrations are compared with conventional processing, one with severe distortions and one with subtle distortions on the conventionally processed sections. The line with subtle distortions is also compared with post-stack depth migration. The results on both lines were very successful. Both have already influenced drilling decisions, and have caused a modification of structural interpretation in the respective areas. Wells have been drilled on each of the lines, and well tops confirm the results. In fact, conventional processing led to incorrect locations for the wells, both of which were dry holes. The depth migrated sections indicate the incorrect placement, and on one line reveals a much better drilling location. This paper reports that even though processing costs are high for pre-stack depth migration, appropriate use can save millions of dollars in dry-hole expense

  19. The implementation of depth measurement and related algorithms based on binocular vision in embedded AM5728

    Science.gov (United States)

    Deng, Zhiwei; Li, Xicai; Shi, Junsheng; Huang, Xiaoqiao; Li, Feiyan

    2018-01-01

    Depth measurement is the most basic measurement in various machine vision, such as automatic driving, unmanned aerial vehicle (UAV), robot and so on. And it has a wide range of use. With the development of image processing technology and the improvement of hardware miniaturization and processing speed, real-time depth measurement using dual cameras has become a reality. In this paper, an embedded AM5728 and the ordinary low-cost dual camera is used as the hardware platform. The related algorithms of dual camera calibration, image matching and depth calculation have been studied and implemented on the hardware platform, and hardware design and the rationality of the related algorithms of the system are tested. The experimental results show that the system can realize simultaneous acquisition of binocular images, switching of left and right video sources, display of depth image and depth range. For images with a resolution of 640 × 480, the processing speed of the system can be up to 25 fps. The experimental results show that the optimal measurement range of the system is from 0.5 to 1.5 meter, and the relative error of the distance measurement is less than 5%. Compared with the PC, ARM11 and DMCU hardware platforms, the embedded AM5728 hardware is good at meeting real-time depth measurement requirements in ensuring the image resolution.

  20. High bit depth infrared image compression via low bit depth codecs

    DEFF Research Database (Denmark)

    Belyaev, Evgeny; Mantel, Claire; Forchhammer, Søren

    2017-01-01

    images via 8 bit depth codecs in the following way. First, an input 16 bit depth image is mapped into 8 bit depth images, e.g., the first image contains only the most significant bytes (MSB image) and the second one contains only the least significant bytes (LSB image). Then each image is compressed.......264/AVC codecs, which are usually available in efficient implementations, and compare their rate-distortion performance with JPEG2000, JPEG-XT and H.265/HEVC codecs supporting direct compression of infrared images in 16 bit depth format. A preliminary result shows that two 8 bit H.264/AVC codecs can...

  1. Energy-depth relation of electrons in bulk targets by Monte-Carlo calculations

    International Nuclear Information System (INIS)

    Gaber, M.; Fitting, H.J.

    1984-01-01

    Monte-Carlo calculations are used to calculate the energy of penetrating electrons as a function of the depth in thick targets of Ti, Fe, Cu, As, In, and Au. It is shown that the mean energy ratio anti E(z)/E 0 decays exponentially with depth z and depends on the backscattering coefficient eta/sub B/ of the bulk material and the maximum range R(E 0 ) of the primary electrons with initial energy E 0 . Thereby a normalized plot anti E/E 0 as a function of the reduced depth z/R becomes possible. (author)

  2. Multi-approach analysis of maximum riverbed scour depth above subway tunnel

    Directory of Open Access Journals (Sweden)

    Jun Chen

    2010-12-01

    Full Text Available When subway tunnels are routed underneath rivers, riverbed scour may expose the structure, with potentially severe consequences. Thus, it is important to identify the maximum scour depth to ensure that the designed buried depth is adequate. There are a range of methods that may be applied to this problem, including the fluvial process analysis method, geological structure analysis method, scour formula method, scour model experiment method, and numerical simulation method. However, the application ranges and forecasting precision of these methods vary considerably. In order to quantitatively analyze the characteristics of the different methods, a subway tunnel passing underneath a river was selected, and the aforementioned five methods were used to forecast the maximum scour depth. The fluvial process analysis method was used to characterize the river regime and evolution trend, which were the baseline for examination of the scour depth of the riverbed. The results obtained from the scour model experiment and the numerical simulation methods are reliable; these two methods are suitable for application to tunnel projects passing underneath rivers. The scour formula method was less accurate than the scour model experiment method; it is suitable for application to lower risk projects such as pipelines. The results of the geological structure analysis had low precision; the method is suitable for use as a secondary method to assist other research methods. To forecast the maximum scour depth of the riverbed above the subway tunnel, a combination of methods is suggested, and the appropriate analysis method should be chosen with respect to the local conditions.

  3. Quantitative AMS depth profiling of the hydrogen isotopes collected in graphite divertor and wall tiles of the tokamak ASDEX-Upgrade

    International Nuclear Information System (INIS)

    Sun, G.Y.; Friedrich, M.; Groetzschel, R.; Buerger, W.; Behrisch, R.; Garcia-Rosales, C.

    1997-01-01

    The accelerator mass spectrometry (AMS) facility at the 3 MV Tandetron in Rossendorf has been applied for quantitative depth profiling of deuterium and tritium in samples cut from graphite protection tiles at the vessel walls of the fusion experiment ASDEX-Upgrade at the Max-Planck-Institut fuer Plasmaphysik in Garching. The tritium originates from D(d,p)T fusion reactions in the plasma and it is implanted in the vessel walls together with deuterium atoms and ions from the plasma. The T concentrations in the surface layers down to the analyzing depth of about 25 μm are in the range of 10 11 to 5 x 10 15 T-atoms/cm 3 corresponding to a tritium retention of 3 x 10 10 to 3.5 x 10 12 T-atoms/cm 2 . The much higher deuterium concentrations in the samples were simultaneously measured by calibrated conventional SIMS. In the surface layers down to the analyzing depth of about 25 μm the deuterium concentrations are between 3 x 10 18 and 8 x 10 21 atoms/cm 3 , corresponding to a deuterium retention of 2.5 x 10 16 to 2.5 x 10 18 atoms/cm 2 The estimated total amount of tritium in the vessel walls is of the same order of magnitude as the total number of neutrons produced in D(d,n) 3 He reactions. (orig.)

  4. Evaluation of FASP, SP3, and iST Protocols for Proteomic Sample Preparation in the Low Microgram Range.

    Science.gov (United States)

    Sielaff, Malte; Kuharev, Jörg; Bohn, Toszka; Hahlbrock, Jennifer; Bopp, Tobias; Tenzer, Stefan; Distler, Ute

    2017-11-03

    Efficient and reproducible sample preparation is a prerequisite for any robust and sensitive quantitative bottom-up proteomics workflow. Here, we performed an independent comparison between single-pot solid-phase-enhanced sample preparation (SP3), filter-aided sample preparation (FASP), and a commercial kit based on the in-StageTip (iST) method. We assessed their performance for the processing of proteomic samples in the low μg range using varying amounts of HeLa cell lysate (1-20 μg of total protein). All three workflows showed similar performances for 20 μg of starting material. When handling sample sizes below 10 μg, the number of identified proteins and peptides as well as the quantitative reproducibility and precision drastically dropped in case of FASP. In contrast, SP3 and iST provided high proteome coverage even in the low μg range. Even when digesting 1 μg of starting material, both methods still enabled the identification of over 3000 proteins and between 25 000 and 30 000 peptides. On average, the quantitative reproducibility between experimental replicates was slightly higher in case of SP3 (R 2 = 0.97 (SP3); R 2 = 0.93 (iST)). Applying SP3 toward the characterization of the proteome of FACS-sorted tumor-associated macrophages in the B16 tumor model enabled the quantification of 2965 proteins and revealed a "mixed" M1/M2 phenotype.

  5. Distortion of depth perception in virtual environments using stereoscopic displays: quantitative assessment and corrective measures

    Science.gov (United States)

    Kleiber, Michael; Winkelholz, Carsten

    2008-02-01

    The aim of the presented research was to quantify the distortion of depth perception when using stereoscopic displays. The visualization parameters of the used virtual reality system such as perspective, haploscopic separation and width of stereoscopic separation were varied. The experiment was designed to measure distortion in depth perception according to allocentric frames of reference. The results of the experiments indicate that some of the parameters have an antithetic effect which allows to compensate the distortion of depth perception for a range of depths. In contrast to earlier research which reported underestimation of depth perception we found that depth was overestimated when using true projection parameters according to the position of the eyes of the user and display geometry.

  6. Depth distribution of carrier lifetime in 65 MeV oxygen ion irradiated silicon wafers

    Energy Technology Data Exchange (ETDEWEB)

    Shinde, N.S. [Ecotopia Science Institute, Division of Energy Science, Nagoya University, Nagoya (Japan); Dahiwale, S.S. [Department of Physics, University of Pune, Pune 411 007 (India); Kanjilal, D. [Nuclear Science Centre, New Delhi (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Pune 411 007 (India); Dhole, S.D. [Department of Physics, University of Pune, Pune 411 007 (India)]. E-mail: sanjay@physics.unipune.ernet.in

    2006-03-15

    CZ-grown, n-doped crystalline Si(1 1 1) of resistivity 60 {omega} cm and 140 {omega} cm were irradiated with 65 MeV energy oxygen ions, in the fluence range of 2 x 10{sup 1}-10{sup 14} ions/cm{sup 2}. The depth and spatial profile of excess minority carrier recombination time {tau} (lifetime) was measured using photoconductive decay (PCD) method. Lifetime measurements were carried out before the stopping range of impinging ions. Results show a monotonous decrease in lifetime with fluence, which is attributed to defect creation mechanism by electronic energy loss based on the thermal spike model. Also, surface modification is expected with a small loss in crystalline quality. This surface is considered to be a multi-crystalline surface with large grain boundaries that act as trapping sites for excess holes in n-Si(1 1 1). Annealing of the irradiated samples showed a near complete recovery at 750 deg. C for a period of 1 h.

  7. MR determination of neonatal spinal canal depth.

    Science.gov (United States)

    Arthurs, Owen; Thayyil, Sudhin; Wade, Angie; Chong, W K Kling; Sebire, Neil J; Taylor, Andrew M

    2012-08-01

    Lumbar punctures (LPs) are frequently performed in neonates and often result in traumatic haemorrhagic taps. Knowledge of the distance from the skin to the middle of the spinal canal (mid-spinal canal depth - MSCD) may reduce the incidence of traumatic taps, but there is little data in extremely premature or low birth weight neonates. Here, we determined the spinal canal depth at post-mortem in perinatal deaths using magnetic resonance imaging (MRI). Spinal canal depth was measured in 78 post-mortem foetuses and perinatal cases (mean gestation 26 weeks; mean weight 1.04kg) at the L3/L4 inter-vertebral space at post-mortem MRI. Both anterior (ASCD) and posterior (PSCD) spinal canal depth were measured; MSCD was calculated and modelled against weight and gestational age. ASCD and PSCD (mm) correlated significantly with weight and gestational age (all r>0.8). A simple linear model MSCD (mm)=3×Weight (kg)+5 was the best fit, identifying an SCD value within the correct range for 87.2% (68/78) (95% CI (78.0, 92.9%)) cases. Gestational age did not add significantly to the predictive value of the model. There is a significant correlation between MSCD and body weight at post-mortem MRI in foetuses and perinatal deaths. If this association holds in preterm neonates, use of the formula MSCD (mm)=3×Weight (kg)+5 could result in fewer traumatic LPs in this population. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  8. MR determination of neonatal spinal canal depth

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen, E-mail: owenarthurs@uk2.net [Centre for Cardiovascular MR, Great Ormond Street Hospital for Children, London WC1N 3JH (United Kingdom); Thayyil, Sudhin, E-mail: s.thayyil@ucl.ac.uk [Academic Neonatology, Institute for Women' s Health, London WC1E 6AU (United Kingdom); Wade, Angie, E-mail: a.wade@ucl.ac.uk [Centre for Paediatric Epidemiology and Biostatistics, UCL Institute of Child Health, London (United Kingdom); Chong, W.K., E-mail: Kling.Chong@gosh.nhs.uk [Paediatric Neuroradiology, Great Ormond Street Hospital for Children, London (United Kingdom); Sebire, Neil J., E-mail: Neil.Sebire@gosh.nhs.uk [Histopathology, Great Ormond Street Hospital for Children, London WC1E 6AU (United Kingdom); Taylor, Andrew M., E-mail: a.taylor76@ucl.ac.uk [Centre for Cardiovascular MR, Cardiorespiratory Unit, Great Ormond Street Hospital for Children and UCL Institute of Cardiovascular Science, London WC1E 6AU (United Kingdom)

    2012-08-15

    Objectives: Lumbar punctures (LPs) are frequently performed in neonates and often result in traumatic haemorrhagic taps. Knowledge of the distance from the skin to the middle of the spinal canal (mid-spinal canal depth - MSCD) may reduce the incidence of traumatic taps, but there is little data in extremely premature or low birth weight neonates. Here, we determined the spinal canal depth at post-mortem in perinatal deaths using magnetic resonance imaging (MRI). Patients and methods: Spinal canal depth was measured in 78 post-mortem foetuses and perinatal cases (mean gestation 26 weeks; mean weight 1.04 kg) at the L3/L4 inter-vertebral space at post-mortem MRI. Both anterior (ASCD) and posterior (PSCD) spinal canal depth were measured; MSCD was calculated and modelled against weight and gestational age. Results: ASCD and PSCD (mm) correlated significantly with weight and gestational age (all r > 0.8). A simple linear model MSCD (mm) = 3 Multiplication-Sign Weight (kg) + 5 was the best fit, identifying an SCD value within the correct range for 87.2% (68/78) (95% CI (78.0, 92.9%)) cases. Gestational age did not add significantly to the predictive value of the model. Conclusion: There is a significant correlation between MSCD and body weight at post-mortem MRI in foetuses and perinatal deaths. If this association holds in preterm neonates, use of the formula MSCD (mm) = 3 Multiplication-Sign Weight (kg) + 5 could result in fewer traumatic LPs in this population.

  9. Non-destructive study of the ion-implantation-affected zone (the long-range effect) in titanium nitride

    International Nuclear Information System (INIS)

    Perry, A.J.; Treglio, J.R.; Schaffer, J.P.; Brunner, J.; Valvoda, V.; Rafaja, D.

    1994-01-01

    The depth to which metal ion implantation can change the structure of titanium nitride coatings is studied using two techniques - positron annihilation spectroscopy (PAS) and glancing-angle X-ray diffraction (GA-XRD) -which are normally applied to the study of bulk materials. The PAS results indicate that the depth to which vacancies are found greatly exceeds the depth at which the implanted material resides. In addition, the concentration of vacancies continues to increase with the dose of implanted ions. The GA-XRD data show that the implantation does not change the residual stress - it remains slightly tensile. Furthermore, there is an increase in the diffraction peak broadening, which is attributed to an increase in the local strain distribution resulting from the generation of a dislocation network at depths of up to several tenths of a micrometer below the implanted zone. The data support the view of a long-range effect, where metal ion implantation causes lattice defect generation within an implantation-affected zone (IAZ) to depths well beyond the implanted zone. The defective nature of the IAZ depends on the implanted dose and the acceleration voltage, as well as on the nature of the ions implanted. In the present work, there is no residual stress in the samples, so this cannot induce the IAZ. ((orig.))

  10. Response of spatial point pattern of halostachys caspica population to ground water depth

    International Nuclear Information System (INIS)

    Niu, P.; Wang, M.; Jiang, P.; Li, M.; Chu, G.

    2017-01-01

    We subjected Halostachys caspica populations to three groundwater depths: shallow ( 4.5 m) in the sample plots, at the diluvial fan of the South Junggar Basin. Both the spatial pattern and spatial association of the population among all three groundwater depths and four growth stages were studied to investigate the impact of groundwater depth on the formation and persistence mechanism of the spatial pattern of Halostachys caspica populations. In this study, Ripley's K function was utilized to characterize spatial patterns and intraspecific associations of H. caspica in three 1-ha plots, as well as to study their relationship with groundwater depth. The seedling supplement severely decreased with increasing groundwater depth, and the population structure changed noticeably due to increased amount of dead standing plants. Different growth stages of the H. caspica population all had aggregated distributions at small scale in the three groundwater depth areas. With increasing scales, the aggregation intensity weakened in all growth stages. Distribution was aggregated at 50 m scales in both the shallow and middle groundwater depth areas, while the deep groundwater depth area followed a random distribution. (author)

  11. High bit depth infrared image compression via low bit depth codecs

    Science.gov (United States)

    Belyaev, Evgeny; Mantel, Claire; Forchhammer, Søren

    2017-08-01

    Future infrared remote sensing systems, such as monitoring of the Earth's environment by satellites, infrastructure inspection by unmanned airborne vehicles etc., will require 16 bit depth infrared images to be compressed and stored or transmitted for further analysis. Such systems are equipped with low power embedded platforms where image or video data is compressed by a hardware block called the video processing unit (VPU). However, in many cases using two 8-bit VPUs can provide advantages compared with using higher bit depth image compression directly. We propose to compress 16 bit depth images via 8 bit depth codecs in the following way. First, an input 16 bit depth image is mapped into 8 bit depth images, e.g., the first image contains only the most significant bytes (MSB image) and the second one contains only the least significant bytes (LSB image). Then each image is compressed by an image or video codec with 8 bits per pixel input format. We analyze how the compression parameters for both MSB and LSB images should be chosen to provide the maximum objective quality for a given compression ratio. Finally, we apply the proposed infrared image compression method utilizing JPEG and H.264/AVC codecs, which are usually available in efficient implementations, and compare their rate-distortion performance with JPEG2000, JPEG-XT and H.265/HEVC codecs supporting direct compression of infrared images in 16 bit depth format. A preliminary result shows that two 8 bit H.264/AVC codecs can achieve similar result as 16 bit HEVC codec.

  12. The penetrating depth analysis of Lunar Penetrating Radar onboard Chang’e-3 rover

    Science.gov (United States)

    Xing, Shu-Guo; Su, Yan; Feng, Jian-Qing; Dai, Shun; Xiao, Yuan; Ding, Chun-Yu; Li, Chun-Lai

    2017-04-01

    Lunar Penetrating Radar (LPR) has successfully been used to acquire a large amount of scientific data during its in-situ detection. The analysis of penetrating depth can help to determine whether the target is within the effective detection range and contribute to distinguishing useful echoes from noise. First, this study introduces two traditional methods, both based on a radar transmission equation, to calculate the penetrating depth. The only difference between the two methods is that the first method adopts system calibration parameters given in the calibration report and the second one uses high-voltage-off radar data. However, some prior knowledge and assumptions are needed in the radar equation and the accuracy of assumptions will directly influence the final results. Therefore, a new method termed the Correlation Coefficient Method (CCM) is provided in this study, which is only based on radar data without any a priori assumptions. The CCM can obtain the penetrating depth according to the different correlation between reflected echoes and noise. To be exact, there is a strong correlation in the useful reflected echoes and a random correlation in the noise between adjacent data traces. In addition, this method can acquire a variable penetrating depth along the profile of the rover, but only one single depth value can be obtained from traditional methods. Through a simulation, the CCM has been verified as an effective method to obtain penetration depth. The comparisons and analysis of the calculation results of these three methods are also implemented in this study. Finally, results show that the ultimate penetrating depth of Channel 1 and the estimated penetrating depth of Channel 2 range from 136.9 m to 165.5 m ({\\varepsilon }r=6.6) and from 13.0 m to 17.5 m ({\\varepsilon }r=2.3), respectively.

  13. Limitations to depth resolution in high-energy, heavy-ion elastic recoil detection analysis

    International Nuclear Information System (INIS)

    Elliman, R.G.; Palmer, G.R.; Ophel, T.R.; Timmers, H.

    1998-01-01

    The depth resolution of heavy-ion elastic recoil detection analysis was examined for Al and Co thin films ranging in thickness from 100 to 400 nm. Measurements were performed with 154 MeV Au ions as the incident beam, and recoils were detected using a gas ionisation detector. Energy spectra were extracted for the Al and Co recoils and the depth resolution determined as a function of film thickness from the width of the high- and low- energy edges. These results were compared with theoretical estimates calculated using the computer program DEPTH. (authors)

  14. A global reference model of Moho depths based on WGM2012

    Science.gov (United States)

    Zhou, D.; Li, C.

    2017-12-01

    The crust-mantle boundary (Moho discontinuity) represents the largest density contrast in the lithosphere, which can be detected by Bouguer gravity anomaly. We present our recent inversion of global Moho depths from World Gravity Map 2012. Because oceanic lithospheres increase in density as they cool, we perform thermal correction based on the plate cooling model. We adopt a temperature Tm=1300°C at the bottom of lithosphere. The plate thickness is tested by varying by 5 km from 90 to 140 km, and taken as 130 km that gives a best-fit crustal thickness constrained by seismic crustal thickness profiles. We obtain the residual Bouguer gravity anomalies by subtracting the thermal correction from WGM2012, and then estimate Moho depths based on the Parker-Oldenburg algorithm. Taking the global model Crust1.0 as a priori constraint, we adopt Moho density contrasts of 0.43 and 0.4 g/cm3 , and initial mean Moho depths of 37 and 20 km in the continental and oceanic domains, respectively. The number of iterations in the inversion is set to be 150, which is large enough to obtain an error lower than a pre-assigned convergence criterion. The estimated Moho depths range between 0 76 km, and are averaged at 36 and 15 km in continental and oceanic domain, respectively. Our results correlate very well with Crust1.0 with differences mostly within ±5.0 km. Compared to the low resolution of Crust1.0 in oceanic domain, our results have a much larger depth range reflecting diverse structures such as ridges, seamounts, volcanic chains and subduction zones. Base on this model, we find that young(95mm/yr) we observe relatively thicker crust. Conductive cooling of lithosphere may constrain the melting of the mantle at ultraslow spreading centers. Lower mantle temperatures indicated by deeper Curie depths at slow and fast spreading ridges may decrease the volume of magmatism and crustal thickness. This new global model of gravity-derived Moho depth, combined with geochemical and Curie

  15. Evaluation of a depth proportional intake device for automatic pumping samplers

    Science.gov (United States)

    Rand E. Eads; Robert B. Thomas

    1983-01-01

    Abstract - A depth proportional intake boom for portable pumping samplers was used to collect suspended sediment samples in two coastal streams for three winters. The boom pivots on the stream bed while a float on the downstream end allows debris to depress the boom and pass without becoming trapped. This equipment modifies point sampling by maintaining the intake...

  16. Centimeter-scale spatial variability in 2-methyl-4-chlorophenoxyacetic acid mineralization increases with depth in agricultural soil

    DEFF Research Database (Denmark)

    Badawi, Nora; Johnsen, Anders R.; Sørensen, Jan

    2013-01-01

    Mineralization of organic chemicals in soil is typically studied using large homogenized samples, but little is known about the small-scale spatial distribution of mineralization potential. We studied centimeter-scale spatial distribution of 2-methyl-4-chlorophenoxyacetic acid (MCPA) mineralization...... was mineralized in all samples in the plow layer, but only about 60% in the transition zone immediately below the plow layer showed mineralization; at greater depth even fewer samples showed mineralization. A patchy spatial distribution of mineralization activity was observed from right below the plow layer...... activity at different depths (8-115 cm) in a Danish agricultural soil profi le using a 96-well microplate C-radiorespirometric method for small-volume samples. The heterotrophic microbial population and specifi c MCPA degraders decreased 10- to 100-fold from the plow layer to a depth of 115 cm. MCPA...

  17. The Viking X ray fluorescence experiment - Sampling strategies and laboratory simulations. [Mars soil sampling

    Science.gov (United States)

    Baird, A. K.; Castro, A. J.; Clark, B. C.; Toulmin, P., III; Rose, H., Jr.; Keil, K.; Gooding, J. L.

    1977-01-01

    Ten samples of Mars regolith material (six on Viking Lander 1 and four on Viking Lander 2) have been delivered to the X ray fluorescence spectrometers as of March 31, 1977. An additional six samples at least are planned for acquisition in the remaining Extended Mission (to January 1979) for each lander. All samples acquired are Martian fines from the near surface (less than 6-cm depth) of the landing sites except the latest on Viking Lander 1, which is fine material from the bottom of a trench dug to a depth of 25 cm. Several attempts on each lander to acquire fresh rock material (in pebble sizes) for analysis have yielded only cemented surface crustal material (duricrust). Laboratory simulation and experimentation are required both for mission planning of sampling and for interpretation of data returned from Mars. This paper is concerned with the rationale for sample site selections, surface sampler operations, and the supportive laboratory studies needed to interpret X ray results from Mars.

  18. The deconvolution of sputter-etching surface concentration measurements to determine impurity depth profiles

    International Nuclear Information System (INIS)

    Carter, G.; Katardjiev, I.V.; Nobes, M.J.

    1989-01-01

    The quasi-linear partial differential continuity equations that describe the evolution of the depth profiles and surface concentrations of marker atoms in kinematically equivalent systems undergoing sputtering, ion collection and atomic mixing are solved using the method of characteristics. It is shown how atomic mixing probabilities can be deduced from measurements of ion collection depth profiles with increasing ion fluence, and how this information can be used to predict surface concentration evolution. Even with this information, however, it is shown that it is not possible to deconvolute directly the surface concentration measurements to provide initial depth profiles, except when only ion collection and sputtering from the surface layer alone occur. It is demonstrated further that optimal recovery of initial concentration depth profiles could be ensured if the concentration-measuring analytical probe preferentially sampled depths near and at the maximum depth of bombardment-induced perturbations. (author)

  19. Problems related to the critical depth of skin

    International Nuclear Information System (INIS)

    Roesch, W.C.

    1986-01-01

    Concern over beta particle dosimetry in the United States led to a number of workshops and symposia at which the National Council on Radiation Protection and Measurements (NCRP) was encouraged to review its recommendations about beta particles. The NCRP responded by forming Scientific Committee No. 80 on Radiobiology of the Skin to start the review. It was directed to prepare recommendations concerning: (1) the depth(s) in the skin at which dose measurements shall be made, (2) the range of depths over which the dose can be averaged, (3) the area of the skin over which the dose can be averaged, and (4) what measurements are required in protecting the whole skin. The recommendations are to apply to all radiations, not just to beta particles. How the measurements are to be made will be left to a later committee. The committee is not required to recommend permissible doses for the skin. The committee has met five times so far to examine the information available on the stochastic and non-stochastic responses of the skin to both ionising and non-ionising radiations. (author)

  20. Problems related to the critical depth of skin

    International Nuclear Information System (INIS)

    Roesch, W.C.

    1985-09-01

    Concern over beta particle dosimetry in the United States led to a number of workshops and symposia at which our National Council on Radiation Protection and Measurements (NCRP) was encouraged to review its recommendations about beta particles. The NCRP responded by forming Scientific Committee No. 80 on Radiobiology of the Skin to start the review. It was directed to prepare recommendations concerning: (1) the depth(s) in the skin at which dose measurements shall be made; (2) the range of depths over which the dose can be averaged; (3) the area of the skin over which the dose can be averaged; and (4) what measurements are required in protecting the whole skin. The recommendations are to apply to all radiations, not just to beta particles. How the measurements are to be made will be left to a later committee. The committee is not required to recommend permissible doses for the skin. The committee has met five times so far to examine the information available on the stochastic and nonstochastic responses of the skin to both ionizing and non-ionizing radiations

  1. A global reference model of Curie-point depths based on EMAG2

    Science.gov (United States)

    Li, Chun-Feng; Lu, Yu; Wang, Jian

    2017-03-01

    In this paper, we use a robust inversion algorithm, which we have tested in many regional studies, to obtain the first global model of Curie-point depth (GCDM) from magnetic anomaly inversion based on fractal magnetization. Statistically, the oceanic Curie depth mean is smaller than the continental one, but continental Curie depths are almost bimodal, showing shallow Curie points in some old cratons. Oceanic Curie depths show modifications by hydrothermal circulations in young oceanic lithosphere and thermal perturbations in old oceanic lithosphere. Oceanic Curie depths also show strong dependence on the spreading rate along active spreading centers. Curie depths and heat flow are correlated, following optimal theoretical curves of average thermal conductivities K = ~2.0 W(m°C)-1 for the ocean and K = ~2.5 W(m°C)-1 for the continent. The calculated heat flow from Curie depths and large-interval gridding of measured heat flow all indicate that the global heat flow average is about 70.0 mW/m2, leading to a global heat loss ranging from ~34.6 to 36.6 TW.

  2. Chironomid-based water depth reconstructions: an independent evaluation of site-specific and local inference models

    NARCIS (Netherlands)

    Engels, S.; Cwynar, L.C.; Rees, A.B.H.; Shuman, B.N.

    2012-01-01

    Water depth is an important environmental variable that explains a significant portion of the variation in the chironomid fauna of shallow lakes. We developed site-specific and local chironomid water-depth inference models using 26 and 104 surface-sediment samples, respectively, from seven

  3. Numbers, biomass and cultivable diversity of microbial populations relate to depth and borehole-specific conditions in groundwater from depths of 4-450 m in Olkiluoto, Finland.

    Science.gov (United States)

    Pedersen, Karsten; Arlinger, Johanna; Eriksson, Sara; Hallbeck, Anna; Hallbeck, Lotta; Johansson, Jessica

    2008-07-01

    Microbiology, chemistry and dissolved gas in groundwater from Olkiluoto, Finland, were analysed over 3 years; samples came from 16 shallow observation tubes and boreholes from depths of 3.9-16.2 m and 14 deep boreholes from depths of 35-742 m. The average total number of cells (TNC) was 3.9 x 10(5) cells per ml in the shallow groundwater and 5.7 x 10(4) cells per ml in the deep groundwater. There was a significant correlation between the amount of biomass, analysed as ATP concentration, and TNC. ATP concentration also correlated with the stacked output of anaerobic most probable number cultivations of nitrate-, iron-, manganese- and sulphate-reducing bacteria, and acetogenic bacteria and methanogens. The numbers and biomass varied at most by approximately three orders of magnitude between boreholes, and TNC and ATP were positively related to the concentration of dissolved organic carbon. Two depth zones were found where the numbers, biomass and diversity of the microbial populations peaked. Shallow groundwater down to a depth of 16.2 m on average contained more biomass and cultivable microorganisms than did deep groundwater, except in a zone at a depth of approximately 300 m where the average biomass and number of cultivable microorganisms approached those of shallow groundwater. Starting at a depth of approximately 300 m, there were steep gradients of decreasing sulphate and increasing methane concentrations with depth; together with the peaks in biomass and sulphide concentration at this depth, these suggest that anaerobic methane oxidation may be a significant process at depth in Olkiluoto.

  4. On-line calculation of ion range and damage distributions

    International Nuclear Information System (INIS)

    Bains, S.H.

    1983-05-01

    The material in this report is intended as a guide to the panels which have been written for running EDEP. It is aimed primarily at new users and those users who wish to run only a limited subset of all the facilities EDEP offers. The options that are available for running EDEP from these panels are: basic Manning and Mueller program - no graphics; graph of projected range and standard deviation in projected range against ion beam energy; graph of deposited energy against depth; and graph of displacements per atom against depth (with (scaled) final ion concentration superimposed). (author)

  5. Compressive laser ranging.

    Science.gov (United States)

    Babbitt, Wm Randall; Barber, Zeb W; Renner, Christoffer

    2011-12-15

    Compressive sampling has been previously proposed as a technique for sampling radar returns and determining sparse range profiles with a reduced number of measurements compared to conventional techniques. By employing modulation on both transmission and reception, compressive sensing in ranging is extended to the direct measurement of range profiles without intermediate measurement of the return waveform. This compressive ranging approach enables the use of pseudorandom binary transmit waveforms and return modulation, along with low-bandwidth optical detectors to yield high-resolution ranging information. A proof-of-concept experiment is presented. With currently available compact, off-the-shelf electronics and photonics, such as high data rate binary pattern generators and high-bandwidth digital optical modulators, compressive laser ranging can readily achieve subcentimeter resolution in a compact, lightweight package.

  6. Spectral-domain low-coherence interferometry for phase-sensitive measurement of Faraday rotation at multiple depths.

    Science.gov (United States)

    Yeh, Yi-Jou; Black, Adam J; Akkin, Taner

    2013-10-10

    We describe a method for differential phase measurement of Faraday rotation from multiple depth locations simultaneously. A polarization-maintaining fiber-based spectral-domain interferometer that utilizes a low-coherent light source and a single camera is developed. Light decorrelated by the orthogonal channels of the fiber is launched on a sample as two oppositely polarized circular states. These states reflect from sample surfaces and interfere with the corresponding states of the reference arm. A custom spectrometer, which is designed to simplify camera alignment, separates the orthogonal channels and records the interference-related oscillations on both spectra. Inverse Fourier transform of the spectral oscillations in k-space yields complex depth profiles, whose amplitudes and phase difference are related to reflectivity and Faraday rotation within the sample, respectively. Information along a full depth profile is produced at the camera speed without performing an axial scan for a multisurface sample. System sensitivity for the Faraday rotation measurement is 0.86 min of arc. Verdet constants of clear liquids and turbid media are measured at 687 nm.

  7. Hardness depth profiling of case hardened steels using a three-dimensional photothermal technique

    International Nuclear Information System (INIS)

    Qu Hong; Wang Chinhua; Guo Xinxin; Mandelis, Andreas

    2010-01-01

    A method of retrieving thermophysical depth profiles of continuously inhomogeneous materials is presented both theoretically and experimentally using the three-dimensional (3-D) photothermal radiometry. A 3-D theoretical model suitable for characterizing solids with arbitrary continuously varying thermophysical property depth profiles and finite (collimated or focused) laser beam spotsize is developed. A numerical fitting algorithm to retrieve the thermophysical profile was demonstrated with three case hardened steel samples. The reconstructed thermal conductivity depth profiles were found to be well anti-correlated with microhardness profiles obtained with the conventional indenter method.

  8. CSDA range, stopping power and mean penetration depth energy relationships in some hydrocarbons and biologic materials for 10 eV to 100 MeV with the modified Rohrlich-Carlson model

    Energy Technology Data Exchange (ETDEWEB)

    Guemues, Hasan [Ondokuz Mayis University, Department of Physics, Faculty of Sciences and Arts, Samsun (Turkey); Bentabet, Abdelouahab [Bordj Bou Arreridj University, LCVRN, SNVSTU Faculty, El Anasser (Algeria)

    2017-05-15

    In this study, for some hydrocarbons and biological compounds, stopping power formula are presented, being valid for low and intermediate electron energies. In addition, calculation of the continuous slowing down approximation range (CSDA range) from the stopping power is also made. Calculation of the CSDA range for some hydrocarbons: C{sub 2}H{sub 6} (ethane), C{sub 4}H{sub 10} (butane), C{sub 6}H{sub 14} (hexane) C{sub 8}H{sub 18} (octane), C{sub 5}H{sub 5}N{sub 5} (adenine) and C{sub 5}H{sub 5}N{sub 5}O (guanine) have been introduced for incident electrons in the energy range 30 eV to 1 MeV. The range of electrons has been calculated within the continuous slowing down approximation (CSDA) using modified Rohrlich and Carlson formula of stopping power. Besides, we have calculated the mean penetration depths using a spherical geometric model developed by Bentabet (Vacuum 86:1855-1859, 35). The results have been compared with the other theoretical results, Monte Carlo code such as PENELOPE predictions and semi-empirical results. The calculated results of CSDA ranges for electrons in the energy range from 20 eV to 100 MeV are found to be in good agreement to within 10% with available date. (orig.)

  9. Complexity and Dynamical Depth

    Directory of Open Access Journals (Sweden)

    Terrence Deacon

    2014-07-01

    Full Text Available We argue that a critical difference distinguishing machines from organisms and computers from brains is not complexity in a structural sense, but a difference in dynamical organization that is not well accounted for by current complexity measures. We propose a measure of the complexity of a system that is largely orthogonal to computational, information theoretic, or thermodynamic conceptions of structural complexity. What we call a system’s dynamical depth is a separate dimension of system complexity that measures the degree to which it exhibits discrete levels of nonlinear dynamical organization in which successive levels are distinguished by local entropy reduction and constraint generation. A system with greater dynamical depth than another consists of a greater number of such nested dynamical levels. Thus, a mechanical or linear thermodynamic system has less dynamical depth than an inorganic self-organized system, which has less dynamical depth than a living system. Including an assessment of dynamical depth can provide a more precise and systematic account of the fundamental difference between inorganic systems (low dynamical depth and living systems (high dynamical depth, irrespective of the number of their parts and the causal relations between them.

  10. Subjective method of refractometry and depth of focus

    Science.gov (United States)

    Sergienko, Nikolai M.; Gromova, Anastasia; Sergienko, Nikolai

    2012-01-01

    Purpose To study the impact of the depth of focus on subjective refraction and distribution of myopic and hyperopic refractions. Methods A total of 450 eyes of 305 subjects in the age range of 23–34 years were recruited for the study. A distribution of refractions was examined using a traditional method of the subjective refractometry on the basis of point-like posterior focus notion. Correction of the results was made on the assumption that the emmetropic eye retains high visual acuity when applying convex lenses with values which are fewer or equal to the depth of focus values. The following values of the depth of focus were used: ±0.55 D, ±0.35 D and ±0.2 D for visual acuity 1.0, 1.5 and 2.0, respectively. Results Application of the traditional method of refractometry produced the following occurrence of refractions: hypermetropia 59.3%, myopia 22% and emmetropia 18.7%. After correction of the initial results of values of the depth of focus the distribution of refractions was as follows: hypermetropia 12.7%, myopia 22% and emmetropia 65.3%. Conclusion The traditional method of subjective refractometry with application of trial lenses was developed on the basis of data of large optical aberrations and significant depth of focus which values should be taken into account during interpretation of results of subjective refractometry. Our data regarding to prevalence of emmetropic refraction falls in line with basic science provisions in respect of the physiology of the eye.

  11. Uncertainty characterization of particle depth measurement using digital in-line holography and the hybrid method.

    Science.gov (United States)

    Gao, Jian; Guildenbecher, Daniel R; Reu, Phillip L; Chen, Jun

    2013-11-04

    In the detection of particles using digital in-line holography, measurement accuracy is substantially influenced by the hologram processing method. In particular, a number of methods have been proposed to determine the out-of-plane particle depth (z location). However, due to the lack of consistent uncertainty characterization, it has been unclear which method is best suited to a given measurement problem. In this work, depth determination accuracies of seven particle detection methods, including a recently proposed hybrid method, are systematically investigated in terms of relative depth measurement errors and uncertainties. Both synthetic and experimental holograms of particle fields are considered at conditions relevant to particle sizing and tracking. While all methods display a range of particle conditions where they are most accurate, in general the hybrid method is shown to be the most robust with depth uncertainty less than twice the particle diameter over a wide range of particle field conditions.

  12. Depth Probing Soft X-ray Microprobe (DPSXRM) for High Resolution Probing of Earth's Microstructural Samples

    Science.gov (United States)

    Dikedi, P. N.

    2015-12-01

    The Cambrian explosion; occurrence of landslides in very dry weather conditions; rockslides; dead, shriveled-up and crumbled leaves possessing fossil records with the semblance of well preserved, flat leaves; abundance of trilobite tracks in lower and higher rock layers; and sailing stones are enigmas demanding demystifications. These enigmas could be elucidated when data on soil structure, texture and strength are provided by some device with submicrometre accuracy; for these and other reasons, the design of a Depth Probing Soft X-ray Microprobe (DPSXRM), is being proposed; it is expected to deliver soft X-rays, at spatial resolution, ϛ≥600nm and to probe at the depth of 0.5m in 17s. The microprobe is portable compared to a synchrotron radiation facility (Diamond Light Source has land size of 43,300m2); spatial resolution,ϛ , of the DPSXRM surpasses those of the X-ray Fluorescence microanalysis (10µm), electron microprobe (1-3µm) and ion microprobe (5->30µm); the DPSXRM has allowance for multiple targets. Vanadium and Manganese membranes are proposed owing to respective 4.952KeV VKα1 and 5.899KeV MnKα1 X-rays emitted, which best suits micro-probing of Earth's microstructural samples. Compound systems like the Kirk-Patrick and Baez and Wolter optics, aspheric mirrors like elliptical and parabolic optics, small apertures and Abbe sine condition are employed to reduce or remove astigmatism, obliquity, comatic and spherical aberrations—leading to good image quality. Results show that 5.899KeV MnKα1 and 4.952KeV VKα1 soft X-rays will travel a distance of 2.75mm to form circular patches of radii 2.2mm and 2.95mm respectively. Zone plate with nth zone radius of 1.5mm must be positioned 1.5mm and 2mm from the electron gun if circular patches must be formed from 4.952KeV VKα1 and 5.899KeV MnKα1 soft X-rays respectively. The focal lengths of 0.25μm≤ƒ≤1.50μm and 0.04μm≤ƒ≤0.2μm covered by 4.952KeV VKα1 and 5.899KeV Mn Kα1 soft X-Rays, will

  13. Quantitative EEG in assessment of anaesthetic depth: comparative study of methodology

    DEFF Research Database (Denmark)

    Thomsen, C. E.; Prior, P. F.

    1996-01-01

    ) and (4) a depth of anaesthesia monitor based on EEG pattern recognition (ADAM). Dose-response curves are presented for stepwise increases in stable end-tidal concentrations of each agent. Results indicated considerable inter-patient variability and the limitations of single EEG measures, particularly......Methodology for assessment of depth of anaesthesia based on analysis of the electroencephalogram (EEG) is controversial. Techniques range from display of single measures, for example median value of the frequency spectrum, to dedicated pattern recognition systems based on measures of several EEG...

  14. On modeling of beryllium molten depths in simulated plasma disruptions

    International Nuclear Information System (INIS)

    Tsotridis, G.; Rother, H.

    1996-01-01

    Plasma-facing components in tokamak-type fusion reactors are subjected to intense heat loads during plasma disruptions. The influence of high heat fluxes on the depth of heat-affected zones of pure beryllium metal and beryllium containing very low levels of surface active impurities is studied by using a two-dimensional transient computer model that solves the equations of motion and energy. Results are presented for a range of energy densities and disruption times. Under certain conditions, impurities, through their effect on surface tension, create convective flows and hence influence the flow intensities and the resulting depths of the beryllium molten layers during plasma disruptions. The calculated depths of the molten layers are also compared with other mathematical models that are based on the assumption that heat is transported through the material by conduction only. 32 refs., 6 figs., 1 tab

  15. Evaluation of carburization depth in service exposed ferritic steel using magnetic Barkhausen noise analysis

    International Nuclear Information System (INIS)

    Vaidyanathan, S.; Moorthy, V.; Jayakumar, T.; Baldev Raj

    1996-01-01

    The feasibility of using magnetic Barkhausen (MBN) measurement for the evaluation of carburization depth in ferritic steels has been reported in this paper. MBN measurements were carried out on samples from service exposed 0.5Cr-0.5Mo ferritic steel tube at different depths (cross section) from carburised ID surface to simulate the variation in carbon concentration gradient within the skin depth of MBN with increasing time of exposure to carburization. It has been observed that the MBN level increases with increasing depth of measurement. An inverse relation between MBN level and carbon content/hardness value has been observed. This study suggests that, the MBN measurements on the carburised surface can be correlated with the concentration gradient within the skin depth of the MBN which would help in predicting the approximate depth of the carburised layer with proper prior calibration. (author)

  16. Depth as an organizer of fish assemblages in floodplain lakes

    Science.gov (United States)

    Miranda, L.E.

    2011-01-01

    Depth reduction is a natural process in floodplain lakes, but in many basins has been accelerated by anthropogenic disturbances. A diverse set of 42 floodplain lakes in the Yazoo River Basin (Mississippi, USA) was examined to test the hypothesis of whether depth reduction was a key determinant of water quality and fish assemblage structure. Single and multiple variable analyses were applied to 10 commonly monitored water variables and 54 fish species. Results showed strong associations between depth and water characteristics, and between depth and fish assemblages. Deep lakes provided less variable environments, clearer water, and a wider range of microhabitats than shallow lakes. The greater environmental stability was reflected by the dominant species in the assemblages, which included a broader representation of large-body species, species less tolerant of extreme water quality, and more predators. Stability in deep lakes was further reflected by reduced among-lake variability in taxa representation. Fish assemblages in shallow lakes were more variable than deep lakes, and commonly dominated by opportunistic species that have early maturity, extended breeding seasons, small adult size, and short lifespan. Depth is a causal factor that drives many physical and chemical variables that contribute to organizing fish assemblages in floodplain lakes. Thus, correlations between fish and water transparency, temperature, oxygen, trophic state, habitat structure, and other environmental descriptors may ultimately be totally or partly regulated by depth. In basins undergoing rapid anthropogenic modifications, local changes forced by depth reductions may be expected to eliminate species available from the regional pool and could have considerable ecological implications. ?? 2010 Springer Basel AG (outside the USA).

  17. Radioactivity concentration variation with depth and assessment of workers' doses in selected mining sites

    Directory of Open Access Journals (Sweden)

    C.U. Nwankwo

    2015-04-01

    Full Text Available Mining workers are exposed to radiation in the process of extracting minerals from the earth crust. In this research, activity concentration of the radionuclides in samples collected at different depths in Komu (0–220 ft and Olode (0–30 ft mining sites, Oyo State, Nigeria and the associated workers' radiological risks were assessed. Gemstones from these sites are mined for local and international markets. The radionuclide contents of the samples were determined using Gamma spectroscopy technique. At Komu, 238U and 232Th concentrations, with few exceptions, increased with depth while that of 40K had no defined pattern. At Olode site, 238U and 232Th concentrations decreased with depth while that of 40K was almost constant. Internal hazard indices at Komu in some cases indicated an unacceptable level of risk to workers. Workers' doses would have been underestimated by between 12 and 55% if the activity concentrations of samples in the pit were not included in the calculation.

  18. Basalt Reactivity Variability with Reservoir Depth in Supercritical CO2 and Aqueous Phases

    Energy Technology Data Exchange (ETDEWEB)

    Schaef, Herbert T.; McGrail, B. Peter; Owen, Antionette T.

    2011-04-01

    Long term storage of CO{sub 2} in geologic formations is currently considered the most attractive option to reduce greenhouse gas emissions while continuing to utilize fossil fuels for energy production. Injected CO{sub 2} is expected to reside as a buoyant water-saturated supercritical fluid in contact with reservoir rock, the caprock system, and related formation waters. As was reported for the first time at the GHGT-9 conference, experiments with basalts demonstrated surprisingly rapid carbonate mineral formation occurring with samples suspended in the scCO{sub 2} phase. Those experiments were limited to a few temperatures and CO{sub 2} pressures representing relatively shallow (1 km) reservoir depths. Because continental flood basalts can extend to depths of 5 km or more, in this paper we extend the earlier results across a pressure-temperature range representative of these greater depths. Different basalt samples, including well cuttings from the borehole used in a pilot-scale basalt sequestration project (Eastern Washington, U.S.) and core samples from the Central Atlantic Magmatic Province (CAMP), were exposed to aqueous solutions in equilibrium with scCO{sub 2} and water-rich scCO{sub 2} at six different pressures and temperatures for select periods of time (30 to 180 days). Conditions corresponding to a shallow injection of CO{sub 2} (7.4 MPa, 34 C) indicate limited reactivity with basalt; surface carbonate precipitates were not easily identified on post-reacted basalt grains. Basalts exposed under identical times appeared increasingly more reacted with simulated depths. Tests, conducted at higher pressures (12.0 MPa) and temperatures (55 C), reveal a wide variety of surface precipitates forming in both fluid phases. Under shallow conditions tiny clusters of aragonite needles began forming in the wet scCO{sub 2} fluid, whereas in the CO{sub 2} saturated water, cation substituted calcite developed thin radiating coatings. Although these types of coatings

  19. Depth distribution of chemical phase concentration determined by grazing incidence X-ray diffraction

    International Nuclear Information System (INIS)

    Novak, P.; Ballo, P.; Dobrocka, E.; Vallo, M.; Lalinsky, T.

    2013-01-01

    Grazing incidence geometry is widely used in X-ray diffraction analysis of thin films. Penetration depth of radiation can be easily changed by an appropriate selection of the angle of incidence α that enables obtaining information from different depths of the sample. This depth can be decreased up to a nanometer scale by approaching the critical angle α_c for total external reflection. This method therefore provides an efficient tool for the analysis of depth distribution of various structural properties, such as the crystallite size, the amorphous fraction, stress or the concentration of chemical phase. However, absorption of the radiation can be characterized by an average attenuation coefficient μ a special care has to be paid to the last property. Variation of chemical phase concentration with depth usually results in depth dependence on the attenuation coefficient. In this contribution a method for determination of depth distribution of a chemical phase is outlined. The method correctly takes into account the depth variation of the attenuation coefficient. The method is tested on thin oxidized Ir layers. The aim of this paper is a comparison two simple model cases with the experimental results. (authors)

  20. Implementation of pencil kernel and depth penetration algorithms for treatment planning of proton beams

    International Nuclear Information System (INIS)

    Russell, K.R.; Saxner, M.; Ahnesjoe, A.; Montelius, A.; Grusell, E.; Dahlgren, C.V.

    2000-01-01

    The implementation of two algorithms for calculating dose distributions for radiation therapy treatment planning of intermediate energy proton beams is described. A pencil kernel algorithm and a depth penetration algorithm have been incorporated into a commercial three-dimensional treatment planning system (Helax-TMS, Helax AB, Sweden) to allow conformal planning techniques using irregularly shaped fields, proton range modulation, range modification and dose calculation for non-coplanar beams. The pencil kernel algorithm is developed from the Fermi-Eyges formalism and Moliere multiple-scattering theory with range straggling corrections applied. The depth penetration algorithm is based on the energy loss in the continuous slowing down approximation with simple correction factors applied to the beam penumbra region and has been implemented for fast, interactive treatment planning. Modelling of the effects of air gaps and range modifying device thickness and position are implicit to both algorithms. Measured and calculated dose values are compared for a therapeutic proton beam in both homogeneous and heterogeneous phantoms of varying complexity. Both algorithms model the beam penumbra as a function of depth in a homogeneous phantom with acceptable accuracy. Results show that the pencil kernel algorithm is required for modelling the dose perturbation effects from scattering in heterogeneous media. (author)

  1. Multiple scattering effects in depth resolution of elastic recoil detection

    International Nuclear Information System (INIS)

    Wielunski, L.S.; Harding, G.L.

    1998-01-01

    Elastic Recoil Detection (ERD) is used to profile hydrogen and other low mass elements in thin films at surface and interfaces in a similar way that Rutherford Backscattering Spectroscopy (RBS) is used to detect and profile heavy elements. It is often assumed that the depth resolutions of these two techniques are similar. However, in contrast to typical RBS, the depth resolution of ERD is limited substantially by multiple scattering. In experimental data analysis and/or spectra simulations of a typical RBS measurement multiple scattering effects are often ignored. Computer programs used in IBA, such as RUMP, HYPRA or RBX do not include multiple scattering effects at all. In this paper, using practical thin metal structures with films containing intentionally introduced hydrogen, we demonstrate experimental ERD depth resolution and sensitivity limitations. The effects of sample material and scattering angle are also discussed. (authors)

  2. Large depth of focus dynamic micro integral imaging for optical see-through augmented reality display using a focus-tunable lens.

    Science.gov (United States)

    Shen, Xin; Javidi, Bahram

    2018-03-01

    We have developed a three-dimensional (3D) dynamic integral-imaging (InIm)-system-based optical see-through augmented reality display with enhanced depth range of a 3D augmented image. A focus-tunable lens is adopted in the 3D display unit to relay the elemental images with various positions to the micro lens array. Based on resolution priority integral imaging, multiple lenslet image planes are generated to enhance the depth range of the 3D image. The depth range is further increased by utilizing both the real and virtual 3D imaging fields. The 3D reconstructed image and the real-world scene are overlaid using an optical see-through display for augmented reality. The proposed system can significantly enhance the depth range of a 3D reconstructed image with high image quality in the micro InIm unit. This approach provides enhanced functionality for augmented information and adjusts the vergence-accommodation conflict of a traditional augmented reality display.

  3. Integration time for the perception of depth from motion parallax.

    Science.gov (United States)

    Nawrot, Mark; Stroyan, Keith

    2012-04-15

    The perception of depth from relative motion is believed to be a slow process that "builds-up" over a period of observation. However, in the case of motion parallax, the potential accuracy of the depth estimate suffers as the observer translates during the viewing period. Our recent quantitative model for the perception of depth from motion parallax proposes that relative object depth (d) can be determined from retinal image motion (dθ/dt), pursuit eye movement (dα/dt), and fixation distance (f) by the formula: d/f≈dθ/dα. Given the model's dynamics, it is important to know the integration time required by the visual system to recover dα and dθ, and then estimate d. Knowing the minimum integration time reveals the incumbent error in this process. A depth-phase discrimination task was used to determine the time necessary to perceive depth-sign from motion parallax. Observers remained stationary and viewed a briefly translating random-dot motion parallax stimulus. Stimulus duration varied between trials. Fixation on the translating stimulus was monitored and enforced with an eye-tracker. The study found that relative depth discrimination can be performed with presentations as brief as 16.6 ms, with only two stimulus frames providing both retinal image motion and the stimulus window motion for pursuit (mean range=16.6-33.2 ms). This was found for conditions in which, prior to stimulus presentation, the eye was engaged in ongoing pursuit or the eye was stationary. A large high-contrast masking stimulus disrupted depth-discrimination for stimulus presentations less than 70-75 ms in both pursuit and stationary conditions. This interval might be linked to ocular-following response eye-movement latencies. We conclude that neural mechanisms serving depth from motion parallax generate a depth estimate much more quickly than previously believed. We propose that additional sluggishness might be due to the visual system's attempt to determine the maximum dθ/dα ratio

  4. Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm

    International Nuclear Information System (INIS)

    Bloch, P.; Altschuler, M.D.; Bjaerngard, B.E.; Kassaee, A.; McDonough, J.

    2000-01-01

    A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence of contaminating electrons, small (6x6cm2 ) fields were used. The measured depth dose is represented as a linear combination of basis functions, namely the depth doses of monoenergetic photon beams derived by Monte Carlo simulations. The weights of the basis functions were obtained with the Cimmino feasibility algorithm, which examines in each iteration the discrepancy between predicted and measured depth dose. For 6 and 15 MV photon beams of a clinical accelerator, the depth dose obtained from the derived spectral weights was within about 1% of the measured depth dose at all depths. Because the problem is ill conditioned, solutions for the spectrum can fluctuate with energy. Physically realistic smooth spectra for these photon beams appeared when a small margin (about ±1%) was attributed to the measured depth dose. The maximum energy of both derived spectra agreed with the measured energy of the electrons striking the target to within 1 MeV. The use of a feasibility method on minimally relaxed constraints provides realistic spectra quickly and interactively. (author)

  5. A Water Temperature Simulation Model for Rice Paddies With Variable Water Depths

    Science.gov (United States)

    Maruyama, Atsushi; Nemoto, Manabu; Hamasaki, Takahiro; Ishida, Sachinobu; Kuwagata, Tsuneo

    2017-12-01

    A water temperature simulation model was developed to estimate the effects of water management on the thermal environment in rice paddies. The model was based on two energy balance equations: for the ground and for the vegetation, and considered the water layer and changes in the aerodynamic properties of its surface with water depth. The model was examined with field experiments for water depths of 0 mm (drained conditions) and 100 mm (flooded condition) at two locations. Daily mean water temperatures in the flooded condition were mostly higher than in the drained condition in both locations, and the maximum difference reached 2.6°C. This difference was mainly caused by the difference in surface roughness of the ground. Heat exchange by free convection played an important role in determining water temperature. From the model simulation, the temperature difference between drained and flooded conditions was more apparent under low air temperature and small leaf area index conditions; the maximum difference reached 3°C. Most of this difference occurred when the range of water depth was lower than 50 mm. The season-long variation in modeled water temperature showed good agreement with an observation data set from rice paddies with various rice-growing seasons, for a diverse range of water depths (root mean square error of 0.8-1.0°C). The proposed model can estimate water temperature for a given water depth, irrigation, and drainage conditions, which will improve our understanding of the effect of water management on plant growth and greenhouse gas emissions through the thermal environment of rice paddies.

  6. Surface analysis and depth profiling of corrosion products formed in lead pipes used to supply low alkalinity drinking water.

    Science.gov (United States)

    Davidson, C M; Peters, N J; Britton, A; Brady, L; Gardiner, P H E; Lewis, B D

    2004-01-01

    Modern analytical techniques have been applied to investigate the nature of lead pipe corrosion products formed in pH adjusted, orthophosphate-treated, low alkalinity water, under supply conditions. Depth profiling and surface analysis have been carried out on pipe samples obtained from the water distribution system in Glasgow, Scotland, UK. X-ray diffraction spectrometry identified basic lead carbonate, lead oxide and lead phosphate as the principal components. Scanning electron microscopy/energy-dispersive x-ray spectrometry revealed the crystalline structure within the corrosion product and also showed spatial correlations existed between calcium, iron, lead, oxygen and phosphorus. Elemental profiling, conducted by means of secondary ion mass spectrometry (SIMS) and secondary neutrals mass spectrometry (SNMS) indicated that the corrosion product was not uniform with depth. However, no clear stratification was apparent. Indeed, counts obtained for carbonate, phosphate and oxide were well correlated within the depth range probed by SIMS. SNMS showed relationships existed between carbon, calcium, iron, and phosphorus within the bulk of the scale, as well as at the surface. SIMS imaging confirmed the relationship between calcium and lead and suggested there might also be an association between chloride and phosphorus.

  7. Correction of a Depth-Dependent Lateral Distortion in 3D Super-Resolution Imaging.

    Directory of Open Access Journals (Sweden)

    Lina Carlini

    Full Text Available Three-dimensional (3D localization-based super-resolution microscopy (SR requires correction of aberrations to accurately represent 3D structure. Here we show how a depth-dependent lateral shift in the apparent position of a fluorescent point source, which we term `wobble`, results in warped 3D SR images and provide a software tool to correct this distortion. This system-specific, lateral shift is typically > 80 nm across an axial range of ~ 1 μm. A theoretical analysis based on phase retrieval data from our microscope suggests that the wobble is caused by non-rotationally symmetric phase and amplitude aberrations in the microscope's pupil function. We then apply our correction to the bacterial cytoskeletal protein FtsZ in live bacteria and demonstrate that the corrected data more accurately represent the true shape of this vertically-oriented ring-like structure. We also include this correction method in a registration procedure for dual-color, 3D SR data and show that it improves target registration error (TRE at the axial limits over an imaging depth of 1 μm, yielding TRE values of < 20 nm. This work highlights the importance of correcting aberrations in 3D SR to achieve high fidelity between the measurements and the sample.

  8. TRAN-STAT: statistics for environmental studies, Number 22. Comparison of soil-sampling techniques for plutonium at Rocky Flats

    International Nuclear Information System (INIS)

    Gilbert, R.O.; Bernhardt, D.E.; Hahn, P.B.

    1983-01-01

    A summary of a field soil sampling study conducted around the Rocky Flats Colorado plant in May 1977 is preseted. Several different soil sampling techniques that had been used in the area were applied at four different sites. One objective was to comparethe average 239 - 240 Pu concentration values obtained by the various soil sampling techniques used. There was also interest in determining whether there are differences in the reproducibility of the various techniques and how the techniques compared with the proposed EPA technique of sampling to 1 cm depth. Statistically significant differences in average concentrations between the techniques were found. The differences could be largely related to the differences in sampling depth-the primary physical variable between the techniques. The reproducibility of the techniques was evaluated by comparing coefficients of variation. Differences between coefficients of variation were not statistically significant. Average (median) coefficients ranged from 21 to 42 percent for the five sampling techniques. A laboratory study indicated that various sample treatment and particle sizing techniques could increase the concentration of plutonium in the less than 10 micrometer size fraction by up to a factor of about 4 compared to the 2 mm size fraction

  9. Oxygen depth profiling in Kr+-implanted polycrystalline alpha titanium by means of 16O(α,α)16O resonance scattering

    International Nuclear Information System (INIS)

    Nsengiyumva, S.; Riviere, J.P.; Raji, A.T.; Comrie, C.M.; Britton, D.T.; Haerting, M.

    2011-01-01

    The 16 O(α,α) 16 O resonance scattering was applied to study the effects of ion implantation on the oxygen distribution in the near surface region of polycrystalline titanium implanted with 180 keV krypton ions at fluences, ranging between 1 x 10 14 and 5 x 10 15 Kr + /cm 2 . Two sample sets were chosen: as-received polycrystalline titanium discs rolled and annealed in half-hard condition which had a thick oxygen layer and similar samples in which this surface layer was removed by polishing. An increase of the mean oxygen concentration observed in both unpolished and polished samples at low fluence suggests a knock-on implantation of surface oxygen atoms. At high fluence, an overall decrease in the mean oxygen concentration and mean oxygen depth suggests an out-diffusion of near-surface oxygen atoms.

  10. Dielectric analysis of depth dependent curing behavior of dental resin composites.

    Science.gov (United States)

    Steinhaus, Johannes; Moeginger, Bernhard; Grossgarten, Mandy; Rosentritt, Martin; Hausnerova, Berenika

    2014-06-01

    The aim of this study is to investigate depth dependent changes of polymerization process and kinetics of visible light-curing (VLC) dental composites in real-time. The measured quantity - "ion viscosity" determined by dielectric analysis (DEA) - provides the depth dependent reaction rate which is correlated to the light intensity available in the corresponding depths derived from light transmission measurements. The ion viscosity curves of two composites (VOCO Arabesk Top and Grandio) were determined during irradiation of 40s with a light-curing unit (LCU) in specimen depths of 0.5/0.75/1.0/1.25/1.5/1.75 and 2.0mm using a dielectric cure analyzer (NETZSCH DEA 231 with Mini IDEX sensors). The thickness dependent light transmission was measured by irradiation composite specimens of various thicknesses on top of a radiometer setup. The shape of the ion viscosity curves depends strongly on the specimen thickness above the sensor. All curves exhibit a range of linear time dependency of the ion viscosity after a certain initiation time. The determined initiation times, the slopes of the linear part of the curves, and the ion viscosities at the end of the irradiation differ significantly with depth within the specimen. The slopes of the ion viscosity curves as well as the light intensity values decrease with depth and fit to the Lambert-Beer law. The corresponding attenuation coefficients are determined for Arabesk Top OA2 to 1.39mm(-1) and 1.48mm(-1), respectively, and for Grandio OA2 with 1.17 and 1.39mm(-1), respectively. For thicknesses exceeding 1.5mm a change in polymerization behavior is observed as the ion viscosity increases subsequent to the linear range indicating some kind of reaction acceleration. The two VLC composites and different specimen thicknesses discriminate significantly in their ion viscosity evolution allowing for a precise characterization of the curing process even with respect to the polymerization mechanism. Copyright © 2014. Published by

  11. Storage and stability of organic carbon in soils as related to depth, occlusion within aggregates, and attachment to minerals

    Directory of Open Access Journals (Sweden)

    M. Schrumpf

    2013-03-01

    Full Text Available Conceptual models suggest that stability of organic carbon (OC in soil depends on the source of plant litter, occlusion within aggregates, incorporation in organo-mineral complexes, and location within the soil profile. Density fractionation is a useful tool to study the relevance of OC stabilization in aggregates and in association with minerals, but it has rarely been applied to full soil profiles. We aim to determine factors shaping the depth profiles of physically unprotected and mineral associated OC and test their relevance for OC stability across a range of European soils that vary in vegetation, soil types, parent material, and land use. At each of the 12 study sites, 10 soil cores were sampled to 60 cm depth and subjected to density separation. Bulk soil samples and density fractions (free light fractions – fLF, occluded light fractions – oLF, heavy fractions – HF were analysed for OC, total nitrogen (TN, δ14C, and Δ14C. Bulk samples were also incubated to determine CO2 evolution per g OC in the samples (specific mineralization rates as an indicator for OC stability. Depth profiles of OC in the light fraction (LF-OC matched those of roots for undisturbed grassland and forest sites, suggesting that roots are shaping the depth distribution of LF-OC. Organic C in the HF declined less with soil depth than LF-OC and roots, especially at grassland sites. The decrease in Δ14C (increase in age of HF-OC with soil depth was related to soil pH as well as to dissolved OC fluxes. This indicates that dissolved OC translocation contributes to the formation of subsoil HF-OC and shapes the Δ14C profiles. The LF at three sites were rather depleted in 14C, indicating the presence of fossil material such as coal and lignite, probably inherited from the parent material. At the other sites, modern Δ14C signatures and positive correlations between specific mineralization rates and fLF-OC indicate the fLF is a potentially available energy and

  12. Depth-profiling by confocal Raman microscopy (CRM): data correction by numerical techniques.

    Science.gov (United States)

    Tomba, J Pablo; Eliçabe, Guillermo E; Miguel, María de la Paz; Perez, Claudio J

    2011-03-01

    The data obtained in confocal Raman microscopy (CRM) depth profiling experiments with dry optics are subjected to significant distortions, including an artificial compression of the depth scale, due to the combined influence of diffraction, refraction, and instrumental effects that operate on the measurement. This work explores the use of (1) regularized deconvolution and (2) the application of simple rescaling of the depth scale as methodologies to obtain an improved, more precise, confocal response. The deconvolution scheme is based on a simple predictive model for depth resolution and the use of regularization techniques to minimize the dramatic oscillations in the recovered response typical of problem inversion. That scheme is first evaluated using computer simulations on situations that reproduce smooth and sharp sample transitions between two materials and finally it is applied to correct genuine experimental data, obtained in this case from a sharp transition (planar interface) between two polymeric materials. It is shown that the methodology recovers very well most of the lost profile features in all the analyzed situations. The use of simple rescaling appears to be only useful for correcting smooth transitions, particularly those extended over distances larger than those spanned by the operative depth resolution, which limits the strategy to the study of profiles near the sample surface. However, through computer simulations, it is shown that the use of water immersion objectives may help to reduce optical distortions and to expand the application window of this simple methodology, which could be useful, for instance, to safely monitor Fickean sorption/desorption of penetrants in polymer films/coatings in a nearly noninvasive way.

  13. Pulse Based Time-of-Flight Range Sensing.

    Science.gov (United States)

    Sarbolandi, Hamed; Plack, Markus; Kolb, Andreas

    2018-05-23

    Pulse-based Time-of-Flight (PB-ToF) cameras are an attractive alternative range imaging approach, compared to the widely commercialized Amplitude Modulated Continuous-Wave Time-of-Flight (AMCW-ToF) approach. This paper presents an in-depth evaluation of a PB-ToF camera prototype based on the Hamamatsu area sensor S11963-01CR. We evaluate different ToF-related effects, i.e., temperature drift, systematic error, depth inhomogeneity, multi-path effects, and motion artefacts. Furthermore, we evaluate the systematic error of the system in more detail, and introduce novel concepts to improve the quality of range measurements by modifying the mode of operation of the PB-ToF camera. Finally, we describe the means of measuring the gate response of the PB-ToF sensor and using this information for PB-ToF sensor simulation.

  14. Determination of in-depth contamination in concrete using a non-destructive technique

    International Nuclear Information System (INIS)

    Boden, S.; Cantrel, E.

    2007-01-01

    The decommissioning of the BR3 (Belgian Reactor 3) approaches its final phase, in which the building structures are being decontaminated and either denuclearized for possible reuse or demolished. Apart from the presence of naturally occurring radionuclides in building materials, other radionuclides might be present due to activation or contamination. The BR3 bioshield has been exposed to rather high neutron leakage fluxes during the reactor operation and is therefore activated. Building structure contamination usually results from leakages during reactor operation, releases due to maintenance works or even dismantling operations. In case of in-depth contamination in concrete it is important to know the exact in-depth profile before decontamination, in order to minimize the amount of radioactive waste that will be produced during the decontamination process and to optimize both the decontamination process and the final control measurements. Common non-destructive analyses used in decommissioning are usually based on the measurement of beta radiation, using e.g. hand-held plastic scintillators. This kind of measurement technique can not be used to determine in-depth contamination. Therefore, most of the decontamination specialists currently base themselves on the results of the radiological analysis of samples taken by core drilling. The use of such a destructive method implies a number of disadvantages: it is time consuming and therefore costly and the different sample preparation steps can conceivably lead to cross-contamination. Moreover, one only receives results of a limited number of points, while the in-depth contamination is usually very inhomogeneously distributed and the relationship between in-depth contamination and surface contamination and/or dose rate (hotspot detection) is generally rather poor.The objective therefore is to test the use of the ISOCS (In Situ Object Counting System) for the determination of contamination depth

  15. Nondestructive strain depth profiling with high energy X-ray diffraction: System capabilities and limitations

    Science.gov (United States)

    Zhang, Zhan; Wendt, Scott; Cosentino, Nicholas; Bond, Leonard J.

    2018-04-01

    Limited by photon energy, and penetration capability, traditional X-ray diffraction (XRD) strain measurements are only capable of achieving a few microns depth due to the use of copper (Cu Kα1) or molybdenum (Mo Kα1) characteristic radiation. For deeper strain depth profiling, destructive methods are commonly necessary to access layers of interest by removing material. To investigate deeper depth profiles nondestructively, a laboratory bench-top high-energy X-ray diffraction (HEXRD) system was previously developed. This HEXRD method uses an industrial 320 kVp X-Ray tube and the Kα1 characteristic peak of tungsten, to produces a higher intensity X-ray beam which enables depth profiling measurement of lattice strain. An aluminum sample was investigated with deformation/load provided using a bending rig. It was shown that the HEXRD method is capable of strain depth profiling to 2.5 mm. The method was validated using an aluminum sample where both the HEXRD method and the traditional X-ray diffraction method gave data compared with that obtained using destructive etching layer removal, performed by a commercial provider. The results demonstrate comparable accuracy up to 0.8 mm depth. Nevertheless, higher attenuation capabilities in heavier metals limit the applications in other materials. Simulations predict that HEXRD works for steel and nickel in material up to 200 µm, but experiment results indicate that the HEXRD strain profile is not practical for steel and nickel material, and the measured diffraction signals are undetectable when compared to the noise.

  16. Toward 1-mm depth precision with a solid state full-field range imaging system

    Science.gov (United States)

    Dorrington, Adrian A.; Carnegie, Dale A.; Cree, Michael J.

    2006-02-01

    Previously, we demonstrated a novel heterodyne based solid-state full-field range-finding imaging system. This system is comprised of modulated LED illumination, a modulated image intensifier, and a digital video camera. A 10 MHz drive is provided with 1 Hz difference between the LEDs and image intensifier. A sequence of images of the resulting beating intensifier output are captured and processed to determine phase and hence distance to the object for each pixel. In a previous publication, we detailed results showing a one-sigma precision of 15 mm to 30 mm (depending on signal strength). Furthermore, we identified the limitations of the system and potential improvements that were expected to result in a range precision in the order of 1 mm. These primarily include increasing the operating frequency and improving optical coupling and sensitivity. In this paper, we report on the implementation of these improvements and the new system characteristics. We also comment on the factors that are important for high precision image ranging and present configuration strategies for best performance. Ranging with sub-millimeter precision is demonstrated by imaging a planar surface and calculating the deviations from a planar fit. The results are also illustrated graphically by imaging a garden gnome.

  17. What controls intermediate depth seismicity in subduction zones?

    Science.gov (United States)

    Florez, M. A.; Prieto, G. A.

    2017-12-01

    Intermediate depth earthquakes seem to cluster in two distinct planes of seismicity along the subducting slab, known as Double Seismic Zones (DSZ). Precise double difference relocations in Tohoku, Japan and northern Chile confirm this pattern with striking accuracy. Furthermore, past studies have used statistical tests on the EHB global seismicity catalog to suggest that DSZs might be a dominant global feature. However, typical uncertainties associated with hypocentral depth prevent us from drawing meaningful conclusions about the detailed structure of intermediate depth seismicity and its relationship to the physical and chemical environment of most subduction zones. We have recently proposed a relative earthquake relocation algorithm based on the precise picking of the P and pP phase arrivals using array processing techniques [Florez and Prieto, 2017]. We use it to relocate seismicity in 24 carefully constructed slab segments that sample every subduction zone in the world. In all of the segments we are able to precisely delineate the structure of the double seismic zone. Our results indicate that whenever the lower plane of seismicity is active enough the width of the DSZ decreases in the down dip direction; the two planes merge at depths between 140 km and 300 km. We develop a method to unambiguously pick the depth of this merging point, the end of the DSZ, which appears to be correlated with the slab thermal parameter. We also confirm that the width of the DSZ increases with plate age. Finally, we estimate b-values for the upper and lower planes of seismicity and explore their relationships to the physical parameters that control slab subduction.

  18. Classification of Surface and Deep Soil Samples Using Linear Discriminant Analysis

    International Nuclear Information System (INIS)

    Wasim, M.; Ali, M.; Daud, M.

    2015-01-01

    A statistical analysis was made of the activity concentrations measured in surface and deep soil samples for natural and anthropogenic gamma-emitting radionuclides. Soil samples were obtained from 48 different locations in Gilgit, Pakistan covering about 50 km/sup 2/ areas at an average altitude of 1550 m above sea level. From each location two samples were collected: one from the top soil (2-6 cm) and another from a depth of 6-10 cm. Four radionuclides including /sup 226/Ra, /sup 232/Th, /sup 40/K and /sup 137/Cs were quantified. The data was analyzed using t-test to find out activity concentration difference between the surface and depth samples. At the surface, the median activity concentrations were 23.7, 29.1, 4.6 and 115 Bq kg/sup -1/ for 226Ra, 232Th, 137Cs and 40K respectively. For the same radionuclides, the activity concentrations were respectively 25.5, 26.2, 2.9 and 191 Bq kg/sup -1/ for the depth samples. Principal component analysis (PCA) was applied to explore patterns within the data. A positive significant correlation was observed between the radionuclides /sup 226/Ra and /sup 232/Th. The data from PCA was further utilized in linear discriminant analysis (LDA) for the classification of surface and depth samples. LDA classified surface and depth samples with good predictability. (author)

  19. In-depth analyses of paleolithic pigments in cave climatic conditions

    Science.gov (United States)

    Touron, Stéphanie; Trichereau, Barbara; Syvilay, Delphine

    2017-07-01

    Painted caves are a specific environment which preservation needs multidisciplinary studies carried out within the different actors. The actions set-up must follow national and European ethics and treaties and be as less invasive as possible to preserve the integrity of the site. Studying colorants in caves should meet these expectations and take into account on-field conditions: high humidity rate, reduced access to electricity, etc. Therefore, non-invasive analyses should be preferred. However, their limits restrict the field of application and sometimes sampling and laboratory analyses must be used to answer the problematic. It is especially true when the pigment is covered by calcite. For this purpose, the Laser-Induced Breakdown Spectroscopy (LIBS) has been assessed to identify the composition with stratigraphic analyses. This study carries out in-depth profile on laboratory samples in conditions close to the ones meet in caves. Samples were prepared on a calcareous substrate using three pigments: red ochre, manganese black and carbon black and two binding media: water and saliva. All samples have been covered by calcite. Four sets of measurements have then been done using the LIBS instrument. The in-depth profiles were obtained using the Standard Normal Variate (SNV) normalization. For all the samples, the pigment layer was identified in the second or third shot, the calcite layer being quite thin. However, the results remain promising with the carbon black pigment but not really conclusive, the carbon being generally quite difficult to quantify.

  20. The cooling history and the depth of detachment faulting at the Atlantis Massif oceanic core complex

    Science.gov (United States)

    Schoolmeesters, Nicole; Cheadle, Michael J.; John, Barbara E.; Reiners, Peter W.; Gee, Jeffrey; Grimes, Craig B.

    2012-10-01

    Oceanic core complexes (OCCs) are domal exposures of oceanic crust and mantle interpreted to be denuded to the seafloor by large slip oceanic detachment faults. We combine previously reported U-Pb zircon crystallization ages with (U-Th)/He zircon thermochronometry and multicomponent magnetic remanence data to determine the cooling history of the footwall to the Atlantis Massif OCC (30°N, MAR) and help establish cooling rates, as well as depths of detachment faulting and gabbro emplacement. We present nine new (U-Th)/He zircon ages for samples from IODP Hole U1309D ranging from 40 to 1415 m below seafloor. These data paired with U-Pb zircon ages and magnetic remanence data constrain cooling rates of gabbroic rocks from the upper 800 m of the central dome at Atlantis Massif as 2895 (+1276/-1162) °C Myr-1 (from ˜780°C to ˜250°C); the lower 600 m of the borehole cooled more slowly at mean rates of ˜500 (+125/-102) °C Myr-1(from ˜780°C to present-day temperatures). Rocks from the uppermost part of the hole also reveal a brief period of slow cooling at rates of ˜300°C Myr-1, possibly due to hydrothermal circulation to ˜4 km depth through the detachment fault zone. Assuming a fault slip rate of 20 mm/yr (from U-Pb zircon ages of surface samples) and a rolling hinge model for the sub-surface fault geometry, we predict that the 780°C isotherm lies at ˜7 km below the axial valley floor, likely corresponding both to the depth at which the semi-brittle detachment fault roots and the probable upper limit of significant gabbro emplacement.

  1. Multiple scattering effects in depth resolution of elastic recoil detection

    Energy Technology Data Exchange (ETDEWEB)

    Wielunski, L.S.; Harding, G.L. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Lindfield, NSW (Australia). Telecommunications and Industrial Physics; Szilagyi, E. [KFKI Research Institute for Particle and Nuclear Physics, Budapest, (Hungary)

    1998-06-01

    Elastic Recoil Detection (ERD) is used to profile hydrogen and other low mass elements in thin films at surface and interfaces in a similar way that Rutherford Backscattering Spectroscopy (RBS) is used to detect and profile heavy elements. It is often assumed that the depth resolutions of these two techniques are similar. However, in contrast to typical RBS, the depth resolution of ERD is limited substantially by multiple scattering. In experimental data analysis and/or spectra simulations of a typical RBS measurement multiple scattering effects are often ignored. Computer programs used in IBA, such as RUMP, HYPRA or RBX do not include multiple scattering effects at all. In this paper, using practical thin metal structures with films containing intentionally introduced hydrogen, we demonstrate experimental ERD depth resolution and sensitivity limitations. The effects of sample material and scattering angle are also discussed. (authors). 19 refs., 4 figs.

  2. Measurement with total scatter calibrate factor at different depths in the calculation of prescription dose

    International Nuclear Information System (INIS)

    Li Lijun; Zhu Haijun; Zhang Xinzhong; Li Feizhou; Song Hongyu

    2004-01-01

    Objective: To evaluate the method of measurement of total scatter calibrate factor (Sc, p). Methods: To measure the Sc, p at different depths on central axis of 6MV, 15MV photon beams through different ways. Results: It was found that the measured data of Sc, p changed with the different depths to a range of 1% - 7%. Using the direct method, the Sc, p measured depth should be the same as the depth in dose normalization point of the prescription dose. If the Sc, p (fsz, d) was measured at the other depths, it could be obtained indirectly by the calculation formula. Conclusions: The Sc, p in the prescription dose can be obtained either by the direct measure method or the indirect calculation formula. But emphasis should be laid on the proper measure depth. (authors)

  3. Electrochemical depth profiling of multilayer metallic structures: An aluminum brazing sheet

    DEFF Research Database (Denmark)

    Afshar, F. Norouzi; Ambat, R.; Kwakernaak, C.

    2012-01-01

    Combinatory localized electrochemical cell and glow discharge optical emission spectrometry (GDOES) measurements were performed to obtain a thorough in depth electrochemical characterization of an aluminum brazing sheet. By defining electrochemical criteria i.e. breakdown potential, corrosion...... potential, cathodic and anodic reactivities, and tracking their changes as a function of depth, the evolution of electrochemical responses through out the material thickness were analyzed and correlated to the corresponding microstructural features. Polarization curves in 1wt% NaCl solution at pH 2.8 were...... obtained at different depths from the surface using controlled sputtering in a glow discharge optical emission spectrometer as a sample preparation technique. The anodic and cathodic reactivity of the top surface areas were significantly higher than that of the bulk, thus indicating these areas to be more...

  4. The effects of forward speed and depth of conservation tillage on soil bulk density

    Directory of Open Access Journals (Sweden)

    A Mahmoudi

    2015-09-01

    , besides the importance of tillage depth and speed in different tiller performance. Materials and methods: This investigation was carried out based on random blocks in the form of split plot experimental design. The main factor, tillage depth, (was 10 and 20cm at both levels and the second factor, tillage speed, (was 6, 8, 10, 12 km h-1 in four levels for Bostan-Abad and 8,10,12,14 km h-1 for Hashtrood with four repetitions. It was carried out using complex tillage made in Sazeh Keshte Bukan Company, which is mostly used in Eastern Azerbaijanand using Massey Ferguson 285 and 399 tractors in Bostab-Abad and Hashtrood, respectively. In this investigation, the characteristics of soil bulk density were studied in two sampling depths of 7 and 17 centimeters. Bulk density is an indicator of soil compaction. It is calculated as the dry weight of soil divided by its volume. This volume includes the volume of soil particles and the volume of pores among soil particles. Bulk density is typically expressed in g cm-3. Results and Discussion: In this study, the effect of both factors on the feature of the soil bulk density at the sampling depth of 5-10 and 15-20 cm was examined. In Bostan-Abad, regarding tillage speed effect for studies characteristics at 1% probability level on soil bulk density was effective. The effect of tillage depth on the soil bulk density was significant at 5% probability level . The interaction effect of tillage speed and depth on soil bulk density was significant at probability level of 1%. Regarding sampling depth effect, the soil bulk density was significant at 5% probability level, respectively. In Hashtrood, the effect of tillage speed on soil bulk density at probability level of 1%, and also tillage depth effect on soil bulk density was significant at 5% level of probability. The interaction effect of tillage speed and depth on soil bulk density was significant at 5% level of probability. Regarding the depth of sampling it was significant on soil bulk

  5. Depth profiling using C60+ SIMS-Deposition and topography development during bombardment of silicon

    International Nuclear Information System (INIS)

    Gillen, Greg; Batteas, James; Michaels, Chris A.; Chi, Peter; Small, John; Windsor, Eric; Fahey, Albert; Verkouteren, Jennifer; Kim, K.J.

    2006-01-01

    A C 60 + primary ion source has been coupled to an ion microscope secondary ion mass spectrometry (SIMS) instrument to examine sputtering of silicon with an emphasis on possible application of C 60 + depth profiling for high depth resolution SIMS analysis of silicon semiconductor materials. Unexpectedly, C 60 + SIMS depth profiling of silicon was found to be complicated by the deposition of an amorphous carbon layer which buries the silicon substrate. Sputtering of the silicon was observed only at the highest accessible beam energies (14.5 keV impact) or by using oxygen backfilling. C 60 + SIMS depth profiling of As delta-doped test samples at 14.5 keV demonstrated a substantial (factor of 5) degradation in depth resolution compared to Cs + SIMS depth profiling. This degradation is thought to result from the formation of an unusual platelet-like grain structure on the SIMS crater bottoms. Other unusual topographical features were also observed on silicon substrates after high primary ion dose C 60 + bombardment

  6. Measuring Compositions in Organic Depth Profiling: Results from a VAMAS Interlaboratory Study

    Energy Technology Data Exchange (ETDEWEB)

    Shard, A. G.; Havelund, Rasmus; Spencer, Steve J.; Gilmore, I. S.; Alexander, Morgan R.; Angerer, Tina B.; Aoyagi, Satoka; Barnes, Jean P.; Benayad, Anass; Bernasik, Andrzej; Ceccone, Giacomo; Counsell, Jonathan D.; Deeks, Christopher; Fletcher, John S.; Graham, Daniel J.; Heuser, Christian; Lee, Tae G.; Marie, Camille; Marzec, Mateusz M.; Mishra, Gautam; Rading, Derk; Renault, Oliver; Scurr, David J.; Shon, Hyun K.; Spampinato, Valentina; Tian, Hua; Wang, Fuyi; Winograd, Nicholas; Wu, Kui; Wucher, Andreas; Zhou, Yufan; Zhu, Zihua

    2015-07-23

    We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study on the measurement of composition in organic depth profiling. Layered samples with known binary compositions of Irganox 1010 and either Irganox 1098 or Fmoc-pentafluoro-L-phenylalanine in each layer were manufactured in a single batch and distributed to more than 20 participating laboratories. The samples were analyzed using argon cluster ion sputtering and either X-ray Photoelectron Spectroscopy (XPS) or Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) to generate depth profiles. Participants were asked to estimate the volume fractions in two of the layers and were provided with the compositions of all other layers. Participants using XPS provided volume fractions within 0.03 of the nominal values. Participants using ToF-SIMS either made no attempt, or used various methods that gave results ranging in error from 0.02 to over 0.10 in volume fraction, the latter representing a 50% relative error for a nominal volume fraction of 0.2. Error was predominantly caused by inadequacy in the ability to compensate for primary ion intensity variations and the matrix effect in SIMS. Matrix effects in these materials appear to be more pronounced as the number of atoms in both the primary analytical ion and the secondary ion increase. Using the participants’ data we show that organic SIMS matrix effects can be measured and are remarkably consistent between instruments. We provide recommendations for identifying and compensating for matrix effects. Finally we demonstrate, using a simple normalization method, that virtually all ToF-SIMS participants could have obtained estimates of volume fraction that were at least as accurate and consistent as XPS.

  7. Application of velocity filtering to optical-flow passive ranging

    Science.gov (United States)

    Barniv, Yair

    1992-01-01

    The performance of the velocity filtering method as applied to optical-flow passive ranging under real-world conditions is evaluated. The theory of the 3-D Fourier transform as applied to constant-speed moving points is reviewed, and the space-domain shift-and-add algorithm is derived from the general 3-D matched filtering formulation. The constant-speed algorithm is then modified to fit the actual speed encountered in the optical flow application, and the passband of that filter is found in terms of depth (sensor/object distance) so as to cover any given range of depths. Two algorithmic solutions for the problems associated with pixel interpolation and object expansion are developed, and experimental results are presented.

  8. Evaluation of mercury and physicochemical parameters in different depths of aquifer water of Thar coalfield, Pakistan.

    Science.gov (United States)

    Ali, Jamshed; Kazi, Tasneem G; Tuzen, Mustafa; Ullah, Naeem

    2017-07-01

    In the current study, mercury (Hg) and physicochemical parameters have been evaluated in aquifer water at different depths of Thar coal field. The water samples were collected from first aquifer (AQ 1 ), second aquifer (AQ 2 ), and third aquifer (AQ 3 ) at three depths, 50-60, 100-120, and 200-250 m, respectively. The results of aquifer water of three depths were interpreted by using different multivariate statistical techniques. Validation of desired method was checked by spiking standard addition method in studied aquifer water samples. The content of Hg in aquifer water samples was measured by cold vapor atomic absorption spectrometer (CV-AAS). These determined values illustrate that the levels of Hg were higher than WHO recommended values for drinking water. All physicochemical parameters were higher than WHO permissible limits for drinking water except pH and SO 4 2- in aquifer water. The positive correlation of Hg with other metals in aquifer water samples of AQ 1 , AQ 2 , and AQ 3 of Thar coalfield except HCO 3 - was observed which might be caused by geochemical minerals. The interpretation of determined values by the cluster technique point out the variations within the water quality parameter as well as sampling location of studied field. The aquifer water AQ 2 was more contaminated with Hg as compared to AQ 1 and AQ 3 ; it may be due to leaching of Hg from coal zone. The concentration of Hg in aquifer water obtained from different depths was found in the following decreasing order: AQ 2  < AQ 1  < AQ 3 .

  9. Demersal fish assemblages off southern New Zealand in relation to depth and temperature

    Science.gov (United States)

    Jacob, W.; McClatchie, S.; Probert, P. K.; Hurst, R. J.

    1998-12-01

    We examined the relationship between demersal fish assemblage and depth, temperature, latitude and longitude off southern New Zealand (46-54°S and 165-180°E) in water depths of 80-787 m. Catch weight data were analysed by two-way indicator analysis (TWIA), groupaverage agglomerative clustering (UPGMA) and Detrended Correspondence Analysis (DCA). The spatial pattern of demersal fish off southern New Zealand conforms to the concept of species groups or fish assemblages related to environmental gradients. Shallow-water assemblages were dominated by species from the families Gempylidae, Squalidae, Triakidae and Moridae, mainly represented by Thyrsites atun, Squalus acanthias, Galeorhinus australis, and Pseudophycis bachus. Deep water assemblages were dominated by Chimaeridae, Argentinidae, Merlucciidae and Macrouridae, mainly represented by Hydrolagus novaezelandiae, Argentina elongata, Macruronus novaezelandiae, and Lepidorhynchus denticulatus. Total catch weight was often dominated by Merlucciidae, Macrouridae and Gempylidae. Fish assemblages were related to discrete ranges of depth (300 m) and temperature (9.5°C), but the range of sediment types was too narrow to show any correlation.

  10. Accuracy of axial depth of cut in micromilling operations - Simplified procedure and uncertainty model

    DEFF Research Database (Denmark)

    Bissacco, Giuliano

    2005-01-01

    , due to the easy breakage particularly when milling on hard materials [1]. Typical values for the errors on the control of the axial depth of cut are in the order of 50 microns, while the aimed depth of cut can be as low as 5 microns. The author has developed a machining procedure for optimal control...... of this investigation is the determination of the uncertainty of the set depth of cut, using the developed procedure, in a range of practical operating conditions and thereby the estimation of the expected accuracy of the method prior to verification of the machined parts....

  11. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry

    International Nuclear Information System (INIS)

    Chetty, Indrin J.; Charland, Paule M.

    2002-01-01

    We have investigated the dependence of the measured optical density on the incident beam energy, field size and depth for a new type of film, Kodak extended dose range (Kodak EDR). Film measurements have been conducted over a range of field sizes (3x3 cm 2 to 25x25 cm 2 ) and depths (d max to 15 cm), for 6 MV and 15 MV photons within a solid water phantom, and the variation in sensitometric response (net optical density versus dose) has been reported. Kodak EDR film is found to have a linear response with dose, from 0 to 350 cGy, which is much higher than that typically seen for Kodak XV film (0-50 cGy). The variation in sensitometric response for Kodak EDR film as a function of field size and depth is observed to be similar to that of Kodak XV film; the optical density varied in the order of 2-3% for field sizes of 3x3 cm 2 and 10x10 cm 2 at depths of d max , 5 cm and 15 cm in the phantom. Measurements for a 25x25 cm 2 field size showed consistently higher optical densities at depths of d max , 5 cm and 15 cm, relative to a 10x10 cm 2 field size at 5 cm depth, with 4-5% differences noted at a depth of 15 cm. Fractional depth dose and profiles conducted with Kodak EDR film showed good agreement (2%/2 mm) with ion chamber measurements for all field sizes except for the 25x25 cm 2 at depths greater than 15 cm, where differences in the order of 3-5% were observed. In addition, Kodak EDR film measurements were found to be consistent with those of Kodak XV film for all fractional depth doses and profiles. The results of this study indicate that Kodak EDR film may be a useful tool for relative dosimetry at higher dose ranges. (author)

  12. Investigation of Kodak extended dose range (EDR) film for megavoltage photon beam dosimetry.

    Science.gov (United States)

    Chetty, Indrin J; Charland, Paule M

    2002-10-21

    We have investigated the dependence of the measured optical density on the incident beam energy, field size and depth for a new type of film, Kodak extended dose range (Kodak EDR). Film measurements have been conducted over a range of field sizes (3 x 3 cm2 to 25 x 25 cm2) and depths (d(max) to 15 cm), for 6 MV and 15 MV photons within a solid water phantom, and the variation in sensitometric response (net optical density versus dose) has been reported. Kodak EDR film is found to have a linear response with dose, from 0 to 350 cGy, which is much higher than that typically seen for Kodak XV film (0-50 cGy). The variation in sensitometric response for Kodak EDR film as a function of field size and depth is observed to be similar to that of Kodak XV film; the optical density varied in the order of 2-3% for field sizes of 3 x 3 cm2 and 10 x 10 cm2 at depths of d(max), 5 cm and 15 cm in the phantom. Measurements for a 25 x 25 cm2 field size showed consistently higher optical densities at depths of d(max), 5 cm and 15 cm, relative to a 10 x 10 cm2 field size at 5 cm depth, with 4-5% differences noted at a depth of 15 cm. Fractional depth dose and profiles conducted with Kodak EDR film showed good agreement (2%/2 mm) with ion chamber measurements for all field sizes except for the 25 x 25 cm2 at depths greater than 15 cm, where differences in the order of 3-5% were observed. In addition, Kodak EDR film measurements were found to be consistent with those of Kodak XV film for all fractional depth doses and profiles. The results of this study indicate that Kodak EDR film may be a useful tool for relative dosimetry at higher dose ranges.

  13. Survey on depth distribution of underground structures for consideration of human intrusion into TRU waste repository

    International Nuclear Information System (INIS)

    Sakamoto, Yoshiaki; Senoo, Muneaki; Sugimoto, Junichiro; Ohishi, Kiyotaka; Okishio, Masanori; Shimizu, Haruo.

    1996-01-01

    Depth distributions of some kinds of underground structure in Japan have been investigated to get an information about suitable depth of underground repository for TRU waste that is arising from reprocessing and MOX fuel fabrication plants. The underground structures investigated in this work were foundation pile of multistoried building, that of elevated expressway, that of JR shinkansen railway, tunnel of subway and wells. The major depth distribution of the underground structures except for the wells was in range from 30 to 50m, and their maximum depth was less than 100m. On the other hand, the 99% of wells was less than 300m in depth. Maximum depth of the other underground structures has been also investigated for a survey of the utilization of underground by artificial structures in Japan. (author)

  14. Method to estimate the effective temperatures of late-type giants using line-depth ratios in the wavelength range 0.97-1.32 μm

    Science.gov (United States)

    Taniguchi, Daisuke; Matsunaga, Noriyuki; Kobayashi, Naoto; Fukue, Kei; Hamano, Satoshi; Ikeda, Yuji; Kawakita, Hideyo; Kondo, Sohei; Sameshima, Hiroaki; Yasui, Chikako

    2018-02-01

    The effective temperature, one of the most fundamental atmospheric parameters of a star, can be estimated using various methods; here, we focus on a method using line-depth ratios (LDRs). This method combines low- and high-excitation lines and makes use of relations between LDRs of these line pairs and the effective temperature. It has an advantage, for example, of being minimally affected by interstellar reddening, which changes stellar colours. We report 81 relations between LDRs and effective temperature established with high-resolution, λ/Δλ ∼ 28 000, spectra of nine G- to M-type giants in the Y and J bands. Our analysis gives the first comprehensive set of LDR relations for this wavelength range. The combination of all these relations can be used to determine the effective temperatures of stars that have 3700 < Teff < 5400 K and -0.5 < [Fe/H] < +0.3 dex, to a precision of ±10 K in the best cases.

  15. Identification of hydrological model parameters for flood forecasting using data depth measures

    Science.gov (United States)

    Krauße, T.; Cullmann, J.

    2011-03-01

    The development of methods for estimating the parameters of hydrological models considering uncertainties has been of high interest in hydrological research over the last years. Besides the very popular Markov Chain Monte Carlo (MCMC) methods which estimate the uncertainty of model parameters in the settings of a Bayesian framework, the development of depth based sampling methods, also entitled robust parameter estimation (ROPE), have attracted an increasing research interest. These methods understand the estimation of model parameters as a geometric search of a set of robust performing parameter vectors by application of the concept of data depth. Recent studies showed that the parameter vectors estimated by depth based sampling perform more robust in validation. One major advantage of this kind of approach over the MCMC methods is that the formulation of a likelihood function within a Bayesian uncertainty framework gets obsolete and arbitrary purpose-oriented performance criteria defined by the user can be integrated without any further complications. In this paper we present an advanced ROPE method entitled the Advanced Robust Parameter Estimation by Monte Carlo algorithm (AROPEMC). The AROPEMC algorithm is a modified version of the original robust parameter estimation algorithm ROPEMC developed by Bárdossy and Singh (2008). AROPEMC performs by merging iterative Monte Carlo simulations, identifying well performing parameter vectors, the sampling of robust parameter vectors according to the principle of data depth and the application of a well-founded stopping criterion applied in supervised machine learning. The principals of the algorithm are illustrated by means of the Rosenbrock's and Rastrigin's function, two well known performance benchmarks for optimisation algorithms. Two case studies demonstrate the advantage of AROPEMC compared to state of the art global optimisation algorithms. A distributed process-oriented hydrological model is calibrated and

  16. Optimization of Variable-Depth Liner Configurations for Increased Broadband Noise Reduction

    Science.gov (United States)

    Jones, M. G.; Watson, W. R.; Nark, D. M.; Schiller, N. H.; Born, J. C.

    2016-01-01

    This paper employs three acoustic propagation codes to explore variable-depth liner configurations for the NASA Langley Grazing Flow Impedance Tube (GFIT). The initial study demonstrates that a variable impedance can acceptably be treated as a uniform impedance if the spatial extent over which this variable impedance occurs is less than one-third of a wavelength of the incident sound. A constrained optimization study is used to design a variable-depth liner and to select an optimization metric. It also provides insight regarding how much attenuation can be achieved with variable-depth liners. Another optimization study is used to design a liner with much finer chamber depth resolution for the Mach 0.0 and 0.3 test conditions. Two liners are designed based on spatial rearrangement of chambers from this liner to determine whether the order is critical. Propagation code predictions suggest this is not the case. Both liners are fabricated via additive manufacturing and tested in the GFIT for the Mach 0.0 condition. Predicted and measured attenuations compare favorably across the full frequency range. These results clearly suggest that the chambers can be arranged in any order, thus offering the potential for innovative liner designs to minimize depth and weight.

  17. A range modulator to produce uniform 38K yield

    International Nuclear Information System (INIS)

    Eilbert, R.F.; Koehler, A.M.; Sisterson, J.M.

    1976-01-01

    A range modulator has been designed for use with a monoenergetic proton beam to achieve uniform yield of a nuclear reaction with depth in a tissue equivalent medium. Uniform yield to +- 1.5% over a 10 cm depth for the reaction 40 Ca(p, 2pn) 38 K has been demonstrated using protons of 160 MeV initial energy. The modulator is a rotating stepped absorber made of stacked acrylic plastic sheets. The angular extent of each sheet is determined by a computer program which also calculates the resultant depth of dose curve. Peaks in the dose curve may be reduced with slight effect on the yield curve. (author)

  18. Data depth and rank-based tests for covariance and spectral density matrices

    KAUST Repository

    Chau, Joris

    2017-06-26

    In multivariate time series analysis, objects of primary interest to study cross-dependences in the time series are the autocovariance or spectral density matrices. Non-degenerate covariance and spectral density matrices are necessarily Hermitian and positive definite, and our primary goal is to develop new methods to analyze samples of such matrices. The main contribution of this paper is the generalization of the concept of statistical data depth for collections of covariance or spectral density matrices by exploiting the geometric properties of the space of Hermitian positive definite matrices as a Riemannian manifold. This allows one to naturally characterize most central or outlying matrices, but also provides a practical framework for rank-based hypothesis testing in the context of samples of covariance or spectral density matrices. First, the desired properties of a data depth function acting on the space of Hermitian positive definite matrices are presented. Second, we propose two computationally efficient pointwise and integrated data depth functions that satisfy each of these requirements. Several applications of the developed methodology are illustrated by the analysis of collections of spectral matrices in multivariate brain signal time series datasets.

  19. Data depth and rank-based tests for covariance and spectral density matrices

    KAUST Repository

    Chau, Joris; Ombao, Hernando; Sachs, Rainer von

    2017-01-01

    In multivariate time series analysis, objects of primary interest to study cross-dependences in the time series are the autocovariance or spectral density matrices. Non-degenerate covariance and spectral density matrices are necessarily Hermitian and positive definite, and our primary goal is to develop new methods to analyze samples of such matrices. The main contribution of this paper is the generalization of the concept of statistical data depth for collections of covariance or spectral density matrices by exploiting the geometric properties of the space of Hermitian positive definite matrices as a Riemannian manifold. This allows one to naturally characterize most central or outlying matrices, but also provides a practical framework for rank-based hypothesis testing in the context of samples of covariance or spectral density matrices. First, the desired properties of a data depth function acting on the space of Hermitian positive definite matrices are presented. Second, we propose two computationally efficient pointwise and integrated data depth functions that satisfy each of these requirements. Several applications of the developed methodology are illustrated by the analysis of collections of spectral matrices in multivariate brain signal time series datasets.

  20. The coefficient of friction of chrysotile gouge at seismogenic depths

    Science.gov (United States)

    Moore, Diane E.; Lockner, D.A.; Tanaka, H.; Iwata, K.

    2004-01-01

    We report new strength data for the serpentine mineral chrysotile at effective normal stresses, ??sn between 40 and 200 MPa in the temperature range 25??-280??C. Overall, the coefficient of friction, ?? (= shear stress/effective normal stress) of water-saturated chrysotile gouge increases both with increasing temperature and ??sn, but the rates vary and the temperature-related increases begin at ???100??C. As a result, a frictional strength minimum (?? = 0.1) occurs at low ??sn at about 100??C. Maximum strength (?? = 0.55) results from a combination of high normal stress and high temperature. The low-strength region is characterized by velocity strengthening and the high-strength region by velocity-weakening behavior. Thoroughly dried chrysotile has ?? = 0.7 and is velocity-weakening. The frictional properties of chrysolite can be explained in its tendency to adsorb large amounts of water that acts as a lubricant during shear. The water is progressively driven off the fiber surfaces with increasing temperature and pressure, causing chrysotile to approach its dry strength. Depth profiles for a chrysotile-lined fault constructed from these data would pass through a strength minimum at ???3 km depth, where sliding should be stable. Below that depth, strength increases rapidly as does the tendency for unstable (seismic) slip. Such a trend would not have been predicted from the room-temperature data. These results therefore illustrate the potential hazards of extrapolating room-temperature friction data to predict fault zone behavior at depth. This depth profile for chrysotile is consistent with the pattern of slip on the Hayward fault, which creeps aseismically at shallow depths but which may be locked below 5 km depth. ?? 2004 by V. H. Winston and Son, Inc. All rights reserved.

  1. Depth migration in transversely isotropic media with explicit operators

    Energy Technology Data Exchange (ETDEWEB)

    Uzcategui, Omar [Colorado School of Mines, Golden, CO (United States)

    1994-12-01

    The author presents and analyzes three approaches to calculating explicit two-dimensional (2D) depth-extrapolation filters for all propagation modes (P, SV, and SH) in transversely isotropic media with vertical and tilted axis of symmetry. These extrapolation filters are used to do 2D poststack depth migration, and also, just as for isotropic media, these 2D filters are used in the McClellan transformation to do poststack 3D depth migration. Furthermore, the same explicit filters can also be used to do depth-extrapolation of prestack data. The explicit filters are derived by generalizations of three different approaches: the modified Taylor series, least-squares, and minimax methods initially developed for isotropic media. The examples here show that the least-squares and minimax methods produce filters with accurate extrapolation (measured in the ability to position steep reflectors) for a wider range of propagation angles than that obtained using the modified Taylor series method. However, for low propagation angles, the modified Taylor series method has smaller amplitude and phase errors than those produced by the least-squares and minimax methods. These results suggest that to get accurate amplitude estimation, modified Taylor series filters would be somewhat preferred in areas with low dips. In areas with larger dips, the least-squares and minimax methods would give a distinctly better delineation of the subsurface structures.

  2. Study on super-resolution three-dimensional range-gated imaging technology

    Science.gov (United States)

    Guo, Huichao; Sun, Huayan; Wang, Shuai; Fan, Youchen; Li, Yuanmiao

    2018-04-01

    Range-gated three dimensional imaging technology is a hotspot in recent years, because of the advantages of high spatial resolution, high range accuracy, long range, and simultaneous reflection of target reflectivity information. Based on the study of the principle of intensity-related method, this paper has carried out theoretical analysis and experimental research. The experimental system adopts the high power pulsed semiconductor laser as light source, gated ICCD as the imaging device, can realize the imaging depth and distance flexible adjustment to achieve different work mode. The imaging experiment of small imaging depth is carried out aiming at building 500m away, and 26 group images were obtained with distance step 1.5m. In this paper, the calculation method of 3D point cloud based on triangle method is analyzed, and 15m depth slice of the target 3D point cloud are obtained by using two frame images, the distance precision is better than 0.5m. The influence of signal to noise ratio, illumination uniformity and image brightness on distance accuracy are analyzed. Based on the comparison with the time-slicing method, a method for improving the linearity of point cloud is proposed.

  3. Ubiquitous Creation of Bas-Relief Surfaces with Depth-of-Field Effects Using Smartphones

    Directory of Open Access Journals (Sweden)

    Bong-Soo Sohn

    2017-03-01

    Full Text Available This paper describes a new method to automatically generate digital bas-reliefs with depth-of-field effects from general scenes. Most previous methods for bas-relief generation take input in the form of 3D models. However, obtaining 3D models of real scenes or objects is often difficult, inaccurate, and time-consuming. From this motivation, we developed a method that takes as input a set of photographs that can be quickly and ubiquitously captured by ordinary smartphone cameras. A depth map is computed from the input photographs. The value range of the depth map is compressed and used as a base map representing the overall shape of the bas-relief. However, the resulting base map contains little information on details of the scene. Thus, we construct a detail map using pixel values of the input image to express the details. The base and detail maps are blended to generate a new depth map that reflects both overall depth and scene detail information. This map is selectively blurred to simulate the depth-of-field effects. The final depth map is converted to a bas-relief surface mesh. Experimental results show that our method generates a realistic bas-relief surface of general scenes with no expensive manual processing.

  4. Multiscale periodicities in aerosol optical depth over India

    International Nuclear Information System (INIS)

    Ramachandran, S; Ghosh, Sayantan; Verma, Amit; Panigrahi, P K

    2013-01-01

    Aerosols exhibit periodic or cyclic variations depending on natural and anthropogenic sources over a region, which can become modulated by synoptic meteorological parameters such as winds, rainfall and relative humidity, and long-range transport. Information on periodicity and phase in aerosol properties assumes significance in prediction as well as examining the radiative and climate effects of aerosols including their association with changes in cloud properties and rainfall. Periodicity in aerosol optical depth, which is a columnar measure of aerosol distribution, is determined using continuous wavelet transform over 35 locations (capitals of states and union territories) in India. Continuous wavelet transform is used in the study because continuous wavelet transform is better suited to the extraction of the periodic and local modulations present in various frequency ranges when compared to Fourier transform. Monthly mean aerosol optical depths (AODs) from the Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Terra satellite at 1° × 1° resolution from January 2001 to December 2012 are used. Annual and quasi-biennial oscillations (QBOs) in AOD are evident in addition to the weak semi-annual (5–6 months) and quasi-triennial oscillations (∼40 months). The semi-annual and annual oscillations are consistent with the seasonal and yearly cycle of variations in AODs. The QBO type periodicity in AOD is found to be non-stationary while the annual period is stationary. The 40 month periodicity indicates the presence of long term correlations in AOD. The observed periodicities in MODIS Terra AODs are also evident in the ground-based AOD measurements made over Kanpur in the Indo-Gangetic Plain. The phase of the periodicity in AOD is stable in the mid-frequency range, while local disturbances in the high-frequency range and long term changes in the atmospheric composition give rise to unstable phases in the low-frequency range. The presence of phase

  5. Sampling for Soil Carbon Stock Assessment in Rocky Agricultural Soils

    Science.gov (United States)

    Beem-Miller, Jeffrey P.; Kong, Angela Y. Y.; Ogle, Stephen; Wolfe, David

    2016-01-01

    Coring methods commonly employed in soil organic C (SOC) stock assessment may not accurately capture soil rock fragment (RF) content or soil bulk density (rho (sub b)) in rocky agricultural soils, potentially biasing SOC stock estimates. Quantitative pits are considered less biased than coring methods but are invasive and often cost-prohibitive. We compared fixed-depth and mass-based estimates of SOC stocks (0.3-meters depth) for hammer, hydraulic push, and rotary coring methods relative to quantitative pits at four agricultural sites ranging in RF content from less than 0.01 to 0.24 cubic meters per cubic meter. Sampling costs were also compared. Coring methods significantly underestimated RF content at all rocky sites, but significant differences (p is less than 0.05) in SOC stocks between pits and corers were only found with the hammer method using the fixed-depth approach at the less than 0.01 cubic meters per cubic meter RF site (pit, 5.80 kilograms C per square meter; hammer, 4.74 kilograms C per square meter) and at the 0.14 cubic meters per cubic meter RF site (pit, 8.81 kilograms C per square meter; hammer, 6.71 kilograms C per square meter). The hammer corer also underestimated rho (sub b) at all sites as did the hydraulic push corer at the 0.21 cubic meters per cubic meter RF site. No significant differences in mass-based SOC stock estimates were observed between pits and corers. Our results indicate that (i) calculating SOC stocks on a mass basis can overcome biases in RF and rho (sub b) estimates introduced by sampling equipment and (ii) a quantitative pit is the optimal sampling method for establishing reference soil masses, followed by rotary and then hydraulic push corers.

  6. In-depth agglomeration of d-metals at Si-on-Mo interfaces

    NARCIS (Netherlands)

    T. Tsarfati,; Zoethout, E.; van de Kruijs, R.; F. Bijkerk,

    2009-01-01

    Reflective Si/Mo multilayer mirrors with protective d-metal surfaces onto a range of upper Mo and Si layer thicknesses have been grown with physical vapor deposition and investigated on diffusion and in-depth compound formation. Laterally inhomogeneous upward Si and downward d-metal diffusion occurs

  7. On the accuracy potential of focused plenoptic camera range determination in long distance operation

    Science.gov (United States)

    Sardemann, Hannes; Maas, Hans-Gerd

    2016-04-01

    Plenoptic cameras have found increasing interest in optical 3D measurement techniques in recent years. While their basic principle is 100 years old, the development in digital photography, micro-lens fabrication technology and computer hardware has boosted the development and lead to several commercially available ready-to-use cameras. Beyond their popular option of a posteriori image focusing or total focus image generation, their basic ability of generating 3D information from single camera imagery depicts a very beneficial option for certain applications. The paper will first present some fundamentals on the design and history of plenoptic cameras and will describe depth determination from plenoptic camera image data. It will then present an analysis of the depth determination accuracy potential of plenoptic cameras. While most research on plenoptic camera accuracy so far has focused on close range applications, we will focus on mid and long ranges of up to 100 m. This range is especially relevant, if plenoptic cameras are discussed as potential mono-sensorial range imaging devices in (semi-)autonomous cars or in mobile robotics. The results show the expected deterioration of depth measurement accuracy with depth. At depths of 30-100 m, which may be considered typical in autonomous driving, depth errors in the order of 3% (with peaks up to 10-13 m) were obtained from processing small point clusters on an imaged target. Outliers much higher than these values were observed in single point analysis, stressing the necessity of spatial or spatio-temporal filtering of the plenoptic camera depth measurements. Despite these obviously large errors, a plenoptic camera may nevertheless be considered a valid option for the application fields of real-time robotics like autonomous driving or unmanned aerial and underwater vehicles, where the accuracy requirements decrease with distance.

  8. Daily snow depth measurements from 195 stations in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Allison, L.J. [ed.] [Oak Ridge National Lab., TN (United States). Carbon Dioxide Information Analysis Center; Easterling, D.R.; Jamason, P.; Bowman, D.P.; Hughes, P.Y.; Mason, E.H. [National Oceanic and Atmospheric Administration, Asheville, NC (United States). National Climatic Data Center

    1997-02-01

    This document describes a database containing daily measurements of snow depth at 195 National Weather Service (NWS) first-order climatological stations in the United States. The data have been assembled and made available by the National Climatic Data Center (NCDC) in Asheville, North Carolina. The 195 stations encompass 388 unique sampling locations in 48 of the 50 states; no observations from Delaware or Hawaii are included in the database. Station selection criteria emphasized the quality and length of station records while seeking to provide a network with good geographic coverage. Snow depth at the 388 locations was measured once per day on ground open to the sky. The daily snow depth is the total depth of the snow on the ground at measurement time. The time period covered by the database is 1893--1992; however, not all station records encompass the complete period. While a station record ideally should contain daily data for at least the seven winter months (January through April and October through December), not all stations have complete records. Each logical record in the snow depth database contains one station`s daily data values for a period of one month, including data source, measurement, and quality flags.

  9. Depth- and range-dependent variation in the performance of aquatic telemetry systems: understanding and predicting the susceptibility of acoustic tag-receiver pairs to close proximity detection interference.

    Science.gov (United States)

    Scherrer, Stephen R; Rideout, Brendan P; Giorli, Giacomo; Nosal, Eva-Marie; Weng, Kevin C

    2018-01-01

    Passive acoustic telemetry using coded transmitter tags and stationary receivers is a popular method for tracking movements of aquatic animals. Understanding the performance of these systems is important in array design and in analysis. Close proximity detection interference (CPDI) is a condition where receivers fail to reliably detect tag transmissions. CPDI generally occurs when the tag and receiver are near one another in acoustically reverberant settings. Here we confirm transmission multipaths reflected off the environment arriving at a receiver with sufficient delay relative to the direct signal cause CPDI. We propose a ray-propagation based model to estimate the arrival of energy via multipaths to predict CPDI occurrence, and we show how deeper deployments are particularly susceptible. A series of experiments were designed to develop and validate our model. Deep (300 m) and shallow (25 m) ranging experiments were conducted using Vemco V13 acoustic tags and VR2-W receivers. Probabilistic modeling of hourly detections was used to estimate the average distance a tag could be detected. A mechanistic model for predicting the arrival time of multipaths was developed using parameters from these experiments to calculate the direct and multipath path lengths. This model was retroactively applied to the previous ranging experiments to validate CPDI observations. Two additional experiments were designed to validate predictions of CPDI with respect to combinations of deployment depth and distance. Playback of recorded tags in a tank environment was used to confirm multipaths arriving after the receiver's blanking interval cause CPDI effects. Analysis of empirical data estimated the average maximum detection radius (AMDR), the farthest distance at which 95% of tag transmissions went undetected by receivers, was between 840 and 846 m for the deep ranging experiment across all factor permutations. From these results, CPDI was estimated within a 276.5 m radius of the

  10. Knee Joint Kinetics in Relation to Commonly Prescribed Squat Loads and Depths

    Science.gov (United States)

    Cotter, Joshua A.; Chaudhari, Ait M.; Jamison, Steve T.; Devor, Steven T.

    2014-01-01

    Controversy exists regarding the safety and performance benefits of performing the squat exercise to depths beyond 90° of knee flexion. Our aim was to compare the net peak external knee flexion moments (pEKFM) experienced over typical ranges of squat loads and depths. Sixteen recreationally trained males (n = 16; 22.7 ± 1.1 yrs; 85.4 ± 2.1 kg; 177.6 ± 0.96 cm; mean ± SEM) with no previous lower limb surgeries or other orthopedic issues and at least one year of consistent resistance training experience while utilizing the squat exercise performed single repetition squat trials in a random order at squat depths of above parallel, parallel, and below parallel. Less than one week before testing, one repetition maximum (1RM) values were found for each squat depth. Subsequent testing required subjects to perform squats at the three depths with three different loads: unloaded, 50% 1RM, and 85% 1RM (nine total trials). Force platform and kinematic data were collected to calculate pEKFM. To assess differences among loads and depths, a two-factor (load and depth) repeated-measures ANOVA with significance set at the P Squat 1RM significantly decreased 13.6% from the above parallel to parallel squat and another 3.6% from the parallel to the below parallel squat (P squat depth and load were increased (P ≤ 0.02). Slopes of pEKFM were greater from unloaded to 50% 1RM than when progressing from 50% to 85% 1RM (P squat loads used with increasing depths are not enough to offset increases in pEKFM. PMID:23085977

  11. Lead Determination and Heterogeneity Analysis in Soil from a Former Firing Range

    Science.gov (United States)

    Urrutia-Goyes, Ricardo; Argyraki, Ariadne; Ornelas-Soto, Nancy

    2017-07-01

    Public places can have an unknown past of pollutants deposition. The exposition to such contaminants can create environmental and health issues. The characterization of a former firing range in Athens, Greece will allow its monitoring and encourage its remediation. This study is focused on Pb contamination in the site due to its presence in ammunition. A dense sampling design with 91 location (10 m apart) was used to determine the spatial distribution of the element in the surface soil of the study area. Duplicates samples were also collected one meter apart from 8 random locations to estimate the heterogeneity of the site. Elemental concentrations were measured using a portable XRF device after simple sample homogenization in the field. Robust Analysis of Variance showed that the contributions to the total variance were 11% from sampling, 1% analytical, and 88% geochemical; reflecting the suitability of the technique. Moreover, the extended random uncertainty relative to the mean concentration was 91.5%; confirming the high heterogeneity of the site. Statistical analysis defined a very high contamination in the area yielding to suggest the need for more in-depth analysis of other contaminants and possible health risks.

  12. Nitrogen Isotopes and Chemocline Depth in Stratified Basins

    Science.gov (United States)

    Fulton, J. M.; Arthur, M. A.

    2006-12-01

    Black shale samples commonly have bulk δ15N values below 0‰, previously interpreted as the result of bacterial nitrogen fixation. In this study we examine the effect of chemocline depth on the δ15N values of water column particulate matter and sediments of two meromictic basins. In particular, we produced δ15N profiles of bulk Black Sea sediments, bulk sediments from Fayetteville Green Lake (FGL), and nutrients and particulates from FGL. We also analyzed pigments from FGL samples to trace the occurrences of deep-dwelling bacteria. Our results suggest that a shallow chemocline leads to relatively 15N-depleted sediments in the absence of nitrogen fixation, probably due to increased availability of ammonium for growth near the chemocline. FGL is meromictic with a shallow chemocline at 20 meters. Ammonium released in the monimolimnion and sediments supports productivity of cyanobacteria and purple (PSB) and green sulfur bacteria near and below the chemocline. The PSB at 20m generate 15N-depleted biomass (δ15N = -3‰), compared with 0 to 3‰ for deep water ammonium. High concentrations of Bchl a extracted from particulate matter at deeper depths, where high sulfide concentrations inhibit PSB growth, suggest that sinking particulate matter contains PSB biomass, transmitting the 15N-depleted signal to the sediments. The Black Sea chemocline depth has varied over the past 7500 years. Published biomarker and pyrite framboid size data suggest that a shallow chemocline persisted through much of the past 7500 years, except for three intervals when the chemocline was deeper than 205 meters. We have measured bulk δ15N on six cores spanning depths from 205 to 2088 meters. Each of the deep chemocline intervals coincides with basin-wide sedimentary δ15N values between 2 and 4‰, compared with values near or below 0‰ for periods characterized by a shallower chemocline. The most 15N-depleted values probably result from a much shallower chemocline than that at present

  13. STUDY ON THE RETRIEVAL OF SNOW DEPTH FROM FY3B/MWRI IN THE ATCTIC

    Directory of Open Access Journals (Sweden)

    L. Li

    2016-06-01

    Full Text Available temperatures. Given the high albedo and low thermal conductivity, snow is regarded as one of the key reasons for the amplification of the warming in polar regions. The distributions of sea ice and snow depth are essential to the whole thermal conduction in the Arctic. This study focused on the retrieval of snow depth on sea ice from brightness temperatures of the MicroWave Radiometer Imager (MWRI onboard the FengYun (FY-3B satellite during the period from December 1, 2010 to April 30, 2011. After cross calibrated to the Advanced Microwave Scanning Radiometer–EOS (AMSR-E Level 2A data, the MWRI brightness temperatures were applied to calculate the sea ice concentrations based on the Arctic Radiation and Turbulence Interaction Study Sea Ice (ASI algorithm. According to the proportional relationship between the snow depth and the surface scattering in 18.7 and 36.5 GHz, the snow depths were derived. In order to eliminate the influence of uncertainties in grain sizes of snow as well as sporadic weather effects, the seven-day averaged snow depths were calculated. Then the results were compared with the snow depths from the AMSR-E Level 3 Sea Ice products. The bias of differences between the MWRI and the AMSR-E Level 3 products are ranged between −1.09 and −0.32 cm,while the standard deviations and the correlation coefficients are ranged from 2.47 to 2.88 cm and from 0.78 to 0.90 for different months. As a result, it could be summarized that FY3B/MWRI showed a promising prospect in retrieving snow depth on sea ice.

  14. Rate-distortion optimization for compressive video sampling

    Science.gov (United States)

    Liu, Ying; Vijayanagar, Krishna R.; Kim, Joohee

    2014-05-01

    The recently introduced compressed sensing (CS) framework enables low complexity video acquisition via sub- Nyquist rate sampling. In practice, the resulting CS samples are quantized and indexed by finitely many bits (bit-depth) for transmission. In applications where the bit-budget for video transmission is constrained, rate- distortion optimization (RDO) is essential for quality video reconstruction. In this work, we develop a double-level RDO scheme for compressive video sampling, where frame-level RDO is performed by adaptively allocating the fixed bit-budget per frame to each video block based on block-sparsity, and block-level RDO is performed by modelling the block reconstruction peak-signal-to-noise ratio (PSNR) as a quadratic function of quantization bit-depth. The optimal bit-depth and the number of CS samples are then obtained by setting the first derivative of the function to zero. In the experimental studies the model parameters are initialized with a small set of training data, which are then updated with local information in the model testing stage. Simulation results presented herein show that the proposed double-level RDO significantly enhances the reconstruction quality for a bit-budget constrained CS video transmission system.

  15. Subring Depth, Frobenius Extensions, and Towers

    Directory of Open Access Journals (Sweden)

    Lars Kadison

    2012-01-01

    Full Text Available The minimum depth d(B,A of a subring B⊆A introduced in the work of Boltje, Danz and Külshammer (2011 is studied and compared with the tower depth of a Frobenius extension. We show that d(B,A < ∞ if A is a finite-dimensional algebra and Be has finite representation type. Some conditions in terms of depth and QF property are given that ensure that the modular function of a Hopf algebra restricts to the modular function of a Hopf subalgebra. If A⊇B is a QF extension, minimum left and right even subring depths are shown to coincide. If A⊇B is a Frobenius extension with surjective Frobenius, homomorphism, its subring depth is shown to coincide with its tower depth. Formulas for the ring, module, Frobenius and Temperley-Lieb structures are noted for the tower over a Frobenius extension in its realization as tensor powers. A depth 3 QF extension is embedded in a depth 2 QF extension; in turn certain depth n extensions embed in depth 3 extensions if they are Frobenius extensions or other special ring extensions with ring structures on their relative Hochschild bar resolution groups.

  16. Depth estimation of laser glass drilling based on optical differential measurements of acoustic response

    Science.gov (United States)

    Gorodesky, Niv; Ozana, Nisan; Berg, Yuval; Dolev, Omer; Danan, Yossef; Kotler, Zvi; Zalevsky, Zeev

    2016-09-01

    We present the first steps of a device suitable for characterization of complex 3D micro-structures. This method is based on an optical approach allowing extraction and separation of high frequency ultrasonic sound waves induced to the analyzed samples. Rapid, non-destructive characterization of 3D micro-structures are limited in terms of geometrical features and optical properties of the sample. We suggest a method which is based on temporal tracking of secondary speckle patterns generated when illuminating a sample with a laser probe while applying known periodic vibration using an ultrasound transmitter. In this paper we investigated lasers drilled through glass vias. The large aspect ratios of the vias possess a challenge for traditional microscopy techniques in analyzing depth and taper profiles of the vias. The correlation of the amplitude vibrations to the vias depths is experimentally demonstrated.

  17. Technical Note: A direct ray-tracing method to compute integral depth dose in pencil beam proton radiography with a multilayer ionization chamber.

    Science.gov (United States)

    Farace, Paolo; Righetto, Roberto; Deffet, Sylvain; Meijers, Arturs; Vander Stappen, Francois

    2016-12-01

    To introduce a fast ray-tracing algorithm in pencil proton radiography (PR) with a multilayer ionization chamber (MLIC) for in vivo range error mapping. Pencil beam PR was obtained by delivering spots uniformly positioned in a square (45 × 45 mm 2 field-of-view) of 9 × 9 spots capable of crossing the phantoms (210 MeV). The exit beam was collected by a MLIC to sample the integral depth dose (IDD MLIC ). PRs of an electron-density and of a head phantom were acquired by moving the couch to obtain multiple 45 × 45 mm 2 frames. To map the corresponding range errors, the two-dimensional set of IDD MLIC was compared with (i) the integral depth dose computed by the treatment planning system (TPS) by both analytic (IDD TPS ) and Monte Carlo (IDD MC ) algorithms in a volume of water simulating the MLIC at the CT, and (ii) the integral depth dose directly computed by a simple ray-tracing algorithm (IDD direct ) through the same CT data. The exact spatial position of the spot pattern was numerically adjusted testing different in-plane positions and selecting the one that minimized the range differences between IDD direct and IDD MLIC . Range error mapping was feasible by both the TPS and the ray-tracing methods, but very sensitive to even small misalignments. In homogeneous regions, the range errors computed by the direct ray-tracing algorithm matched the results obtained by both the analytic and the Monte Carlo algorithms. In both phantoms, lateral heterogeneities were better modeled by the ray-tracing and the Monte Carlo algorithms than by the analytic TPS computation. Accordingly, when the pencil beam crossed lateral heterogeneities, the range errors mapped by the direct algorithm matched better the Monte Carlo maps than those obtained by the analytic algorithm. Finally, the simplicity of the ray-tracing algorithm allowed to implement a prototype procedure for automated spatial alignment. The ray-tracing algorithm can reliably replace the TPS method in MLIC PR for in

  18. Acoustic Transmission Loss and Prolonged Coda Durations of Seismic Airgunning at Intermediate Ranges in the Lau Back-Arc Basin

    Science.gov (United States)

    Scheip, C.; Bohnenstiehl, D. R.; Matsumoto, H.; Dziak, R. P.; Lau, T. A.; Fowler, M.; Conder, J. A.; Wiens, D. A.

    2010-12-01

    During January-February of 2009, the R/V Marcus G. Langseth carried out an active-source seismic survey in the Lau Back-Arc Basin (20 S, 175 W) [Dunn et al., OS13A-1157, 2009]. Although the survey was designed to image sub-seafloor structures, the acoustic energy also was recorded by an array of seven autonomous underwater hydrophones positioned at a range of 29-416 km. The seismic survey used a 36-gun array with a source depth less than 10 m, and fired approximately 9400 shots. The hydrophone receivers were calibrated omni-directional sensors sampled at 250 Hz and moored at a depth of 1000 m. The acoustic environment of the tropical Lau Basin is unique in that the critical depth of the sound channel lies well below the relatively shallow (2000-2500 m) depth of the seafloor. Consequently, sound channel propagation is everywhere bottom limited. The initial arrival of each airgun pulse shows a short rise time, often less than two seconds from initial arrival to peak amplitude; however the coda duration often exceeds sixty seconds. This can be attributed to multipath propagation and seafloor scattering during multiple reflections from the seafloor. Moreover, received level (rms re 1uPa at 1m) versus range data indicate a transmission loss greater than 20log(range), thus exceeding the prediction for a purely spherical spreading model. This also is explained by strong interaction with the seafloor in this bottom-limited setting. The purpose of this paper is to quantify received signal characteristics of the airgun shots and compare predicted variability from numerical models with the observed variability. The results will improve source level estimates for volcanic and tectonic signals within the Lau Basin. They also will be used to assess the possible environmental impacts of further active-source seismic work in bottom-limited settings.

  19. In-depth survey report of Scoular Elevator, Salina, Kansas

    Energy Technology Data Exchange (ETDEWEB)

    Zaebst, D.D.

    1987-06-01

    An in/depth industrial hygiene survey of exposures to phosphine during the use of aluminum phosphide was conducted as part of a survey on exposure to grain fumigants. Area monitoring and breathing-zone sampling for phosphine were conducted during the addition of aluminum phosphide to grain during turning operations; source samples and peak personal exposures were also analyzed. Major sources of personal exposure included the escape of air from the bin headspace during filling with treated grain, filling and emptying of the phosphide pellet dispenser, and infiltration from the treated grain bin and from the pellet dispenser itself into adjacent air space. Relatively good dust control was indicated by the total dust samples collected during the survey. Measures recommended by the author are in the report.

  20. Small scale temporal distribution of radiocesium in undisturbed coniferous forest soil: Radiocesium depth distribution profiles.

    Science.gov (United States)

    Teramage, Mengistu T; Onda, Yuichi; Kato, Hiroaki

    2016-04-01

    The depth distribution of pre-Fukushima and Fukushima-derived (137)Cs in undisturbed coniferous forest soil was investigated at four sampling dates from nine months to 18 months after the Fukushima nuclear power plant accident. The migration rate and short-term temporal variability among the sampling profiles were evaluated. Taking the time elapsed since the peak deposition of pre-Fukushima (137)Cs and the median depth of the peaks, its downward displacement rates ranged from 0.15 to 0.67 mm yr(-1) with a mean of 0.46 ± 0.25 mm yr(-1). On the other hand, in each examined profile considerable amount of the Fukushima-derived (137)Cs was found in the organic layer (51%-92%). At this moment, the effect of time-distance on the downward distribution of Fukushima-derived (137)Cs seems invisible as its large portion is still found in layers where organic matter is maximal. This indicates that organic matter seems the primary and preferential sorbent of radiocesium that could be associated with the physical blockage of the exchanging sites by organic-rich dusts that act as a buffer against downward propagation of radiocesium, implying radiocesium to be remained in the root zone for considerable time period. As a result, this soil section can be a potential source of radiation dose largely due to high radiocesium concentration coupled with its low density. Generally, such kind of information will be useful to establish a dynamic safety-focused decision support system to ease and assist management actions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Influence of crack length on crack depth measurement by an alternating current potential drop technique

    International Nuclear Information System (INIS)

    Raja, Manoj K; Mahadevan, S; Rao, B P C; Behera, S P; Jayakumar, T; Raj, Baldev

    2010-01-01

    An alternating current potential drop (ACPD) technique is used for sizing depth of surface cracks in metallic components. Crack depth estimations are prone to large deviations when ACPD measurements are made on very shallow and finite length cracks, especially in low conducting materials such as austenitic stainless steel (SS). Detailed studies have been carried out to investigate the influence of crack length and aspect ratio (length to depth) on depth estimation by performing measurements on electric discharge machined notches with the aspect ratio in the range of 1 to 40 in SS plates. In notches with finite length, an additional path for current to flow through the surface along the length is available causing the notch depths to be underestimated. The experimentally observed deviation in notch depth estimates is explained from a simple mathematical approach using the equivalent resistive circuit model based on the additional path available for the current to flow. A scheme is proposed to accurately measure the depth of cracks with finite lengths in SS components

  2. The influence of water depth on kinematic and spatiotemporal gait parameters during aquatic treadmill walking.

    Science.gov (United States)

    Jung, Taeyou; Kim, Yumi; Lim, Hyosok; Vrongistinos, Konstantinos

    2018-01-16

    The purpose of this study was to investigate kinematic and spatiotemporal variables of aquatic treadmill walking at three different water depths. A total of 15 healthy individuals completed three two-minute walking trials at three different water depths. The aquatic treadmill walking was conducted at waist-depth, chest-depth and neck-depth, while a customised 3-D underwater motion analysis system captured their walking. Each participant's self-selected walking speed at the waist level was used as a reference speed, which was applied to the remaining two test conditions. A repeated measures ANOVA showed statistically significant differences among the three walking conditions in stride length, cadence, peak hip extension, hip range of motion (ROM), peak ankle plantar flexion and ankle ROM (All p values hip ROM as the water depth rose from waist and chest to the neck level. However, our study found no significant difference between waist and chest level water in all variables. Hydrodynamics, such as buoyancy and drag force, in response to changes in water depths, can affect gait patterns during aquatic treadmill walking.

  3. The depth distribution of bubbles and fracture in He+ and D+ irradiated copper

    International Nuclear Information System (INIS)

    Johnson, P.B.; Mazey, D.J.

    1982-01-01

    Transmission electron microscopy is used to investigate the spatial arrangement and distribution with depth of gas bubbles produced in Cu by irradiation at 320 K to a level approx. equal to 4 x 10 21 30 keV He + m -2 . At the depth of maximum bubble size the bubbles are random and large (up to approx. equal to 10 nm across). At both shallower and greater depths the gas bubbles are smaller (approx. equal to 2 nm diam), much more uniform in size and ordered on an fcc superlattice with a lattice constant of a 1 approx. equal to 7.7 nm which (in contrast to the average bubble size) is independent of depth. It is suggested that blistering results from fracture, at a depth near the mean projected range, between large randomly-ordered bubbles which have evolved from smaller bubbles of uniform size arranged on a superlattice. For the particular case of D + irradiation of Cu at 120 K evidence is found to suggest that the fracture mechanisms involved in blistering and flaking are quite different. (orig.)

  4. Glow discharge depth analysis of metallic elements in steels

    International Nuclear Information System (INIS)

    Berneron, R.

    The glow discharge lamp designed by Grimm gives new possibilities in the optical spectrometry. The plasma produced is a cool emissive source and its advantages are the following: low spectral background, no reabsorption, linear calibration, very stable emission, very high yield. The sputtering produced by ionic bombardment of the sample enables the depth repartition of several elements to be made in the same run [fr

  5. A new method for depth profiling reconstruction in confocal microscopy

    Science.gov (United States)

    Esposito, Rosario; Scherillo, Giuseppe; Mensitieri, Giuseppe

    2018-05-01

    Confocal microscopy is commonly used to reconstruct depth profiles of chemical species in multicomponent systems and to image nuclear and cellular details in human tissues via image intensity measurements of optical sections. However, the performance of this technique is reduced by inherent effects related to wave diffraction phenomena, refractive index mismatch and finite beam spot size. All these effects distort the optical wave and cause an image to be captured of a small volume around the desired illuminated focal point within the specimen rather than an image of the focal point itself. The size of this small volume increases with depth, thus causing a further loss of resolution and distortion of the profile. Recently, we proposed a theoretical model that accounts for the above wave distortion and allows for a correct reconstruction of the depth profiles for homogeneous samples. In this paper, this theoretical approach has been adapted for describing the profiles measured from non-homogeneous distributions of emitters inside the investigated samples. The intensity image is built by summing the intensities collected from each of the emitters planes belonging to the illuminated volume, weighed by the emitters concentration. The true distribution of the emitters concentration is recovered by a new approach that implements this theoretical model in a numerical algorithm based on the Maximum Entropy Method. Comparisons with experimental data and numerical simulations show that this new approach is able to recover the real unknown concentration distribution from experimental profiles with an accuracy better than 3%.

  6. Evaluation of color encodings for high dynamic range pixels

    Science.gov (United States)

    Boitard, Ronan; Mantiuk, Rafal K.; Pouli, Tania

    2015-03-01

    Traditional Low Dynamic Range (LDR) color spaces encode a small fraction of the visible color gamut, which does not encompass the range of colors produced on upcoming High Dynamic Range (HDR) displays. Future imaging systems will require encoding much wider color gamut and luminance range. Such wide color gamut can be represented using floating point HDR pixel values but those are inefficient to encode. They also lack perceptual uniformity of the luminance and color distribution, which is provided (in approximation) by most LDR color spaces. Therefore, there is a need to devise an efficient, perceptually uniform and integer valued representation for high dynamic range pixel values. In this paper we evaluate several methods for encoding colour HDR pixel values, in particular for use in image and video compression. Unlike other studies we test both luminance and color difference encoding in a rigorous 4AFC threshold experiments to determine the minimum bit-depth required. Results show that the Perceptual Quantizer (PQ) encoding provides the best perceptual uniformity in the considered luminance range, however the gain in bit-depth is rather modest. More significant difference can be observed between color difference encoding schemes, from which YDuDv encoding seems to be the most efficient.

  7. Comparison in performance of sediment microbial fuel cells according to depth of embedded anode.

    Science.gov (United States)

    An, Junyeong; Kim, Bongkyu; Nam, Jonghyeon; Ng, How Yong; Chang, In Seop

    2013-01-01

    Five rigid graphite plates were embedded in evenly divided sections of sediment, ranging from 2 cm (A1) to 10 cm (A5) below the top sediment layer. The maximum power and current of the MFCs increased in depth order; however, despite the increase in the internal resistance, the power and current density of the A5 MFC were 2.2 and 3.5 times higher, respectively, than those of the A1 MFC. In addition, the anode open circuit potentials (OCPs) of the sediment microbial fuel cells (SMFCs) became more negative with sediment depth. Based on these results, it could be then concluded that as the anode-embedding depth increases, that the anode environment is thermodynamically and kinetically favorable to anodophiles or electrophiles. Therefore, the anode-embedding depth should be considered an important parameter that determines the performance of SMFCs, and we posit that the anode potential could be one indicator for selecting the anode-embedding depth. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Ensemble Sampling

    OpenAIRE

    Lu, Xiuyuan; Van Roy, Benjamin

    2017-01-01

    Thompson sampling has emerged as an effective heuristic for a broad range of online decision problems. In its basic form, the algorithm requires computing and sampling from a posterior distribution over models, which is tractable only for simple special cases. This paper develops ensemble sampling, which aims to approximate Thompson sampling while maintaining tractability even in the face of complex models such as neural networks. Ensemble sampling dramatically expands on the range of applica...

  9. Pulsed glow discharge mass spectrometry for molecular depth profiling of polymers

    International Nuclear Information System (INIS)

    Lobo, L.; Pereiro, R.; Sanz-Medel, A.; Bordel, N.; Pisonero, J.; Licciardello, A.; Tuccitto, N.; Tempez, A.; Chapon, P.

    2009-01-01

    Full text: Nowadays thin films of polymeric materials involve a wide range of industrial applications, so techniques capable of providing in-depth profile information are required. Most of the techniques available for this purpose are based on the use of energetic particle beams which interact with polymers producing undesirable physicochemical modifications. Radiofrequency pulsed glow discharge (rf-pulsed-GD) coupled to time-of-flight mass spectrometry (TOFMS) could afford the possibility of acquiring both elemental and molecular information creating minimal damage to surfaces and thereby obtaining depth profiles. This work will evaluate rf-GDs coupled to an orthogonal TOFMS for direct analysis of polymers. (author)

  10. Radon depth migration

    International Nuclear Information System (INIS)

    Hildebrand, S.T.; Carroll, R.J.

    1993-01-01

    A depth migration method is presented that used Radon-transformed common-source seismograms as input. It is shown that the Radon depth migration method can be extended to spatially varying velocity depth models by using asymptotic ray theory (ART) to construct wavefield continuation operators. These operators downward continue an incident receiver-array plane wave and an assumed point-source wavefield into the subsurface. The migration velocity model is constrain to have longer characteristic wavelengths than the dominant source wavelength such that the ART approximations for the continuation operators are valid. This method is used successfully to migrate two synthetic data examples: (1) a point diffractor, and (2) a dipping layer and syncline interface model. It is shown that the Radon migration method has a computational advantage over the standard Kirchhoff migration method in that fewer rays are computed in a main memory implementation

  11. A systematic method for characterizing the time-range performance of ground penetrating radar

    International Nuclear Information System (INIS)

    Strange, A D

    2013-01-01

    The fundamental performance of ground penetrating radar (GPR) is linked to the ability to measure the signal time-of-flight in order to provide an accurate radar-to-target range estimate. Having knowledge of the actual time range and timing nonlinearities of a trace is therefore important when seeking to make quantitative range estimates. However, very few practical methods have been formally reported in the literature to characterize GPR time-range performance. This paper describes a method to accurately measure the true time range of a GPR to provide a quantitative assessment of the timing system performance and detect and quantify the effects of timing nonlinearity due to timing jitter. The effect of varying the number of samples per trace on the true time range has also been investigated and recommendations on how to minimize the effects of timing errors are described. The approach has been practically applied to characterize the timing performance of two commercial GPR systems. The importance of the method is that it provides the GPR community with a practical method to readily characterize the underlying accuracy of GPR systems. This in turn leads to enhanced target depth estimation as well as facilitating the accuracy of more sophisticated GPR signal processing methods. (paper)

  12. Wide-range bipolar pulse conductance instrument employing current and voltage modes with sampled or integrated signal acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Calhoun, R K; Holler, F J [Kentucky Univ., Lexington, KY (United States). Dept. of Chemistry; Geiger, jr, R F; Nieman, T A [Illinois Univ., Urbana, IL (United States). Dept. of Chemistry; Caserta, K J [Procter and Gamble Co., Cincinnati, OH (United States)

    1991-11-05

    An instrument for measuring solution conductance using the bipolar pulse technique is described. The instrument is capable of measuring conductances in the range of 5x10{sup -9}-10{Omega}{sup -1} with 1% accuracy or better in as little as 32 {mu}s. Accuracy of 0.001-0.01% is achievable over the range 1x10{sup -6}-1{Omega}{sup -1}. Circuitry and software are described that allow the instrument to adjust automatically the pulse height, pulse duration, excitation mode (current or voltage pulse) and data acquisition mode (sampled or integrated) to acquire data of optimum accuracy and precision. The urease-catalyzed decomposition of urea is used to illustrate the versality of the instrument, and other applications are cited. (author). 60 refs.; 7 figs.; 2 tabs.

  13. Ultrasound data for laboratory calibration of an analytical model to calculate crack depth on asphalt pavements

    Directory of Open Access Journals (Sweden)

    Miguel A. Franesqui

    2017-08-01

    Full Text Available This article outlines the ultrasound data employed to calibrate in the laboratory an analytical model that permits the calculation of the depth of partial-depth surface-initiated cracks on bituminous pavements using this non-destructive technique. This initial calibration is required so that the model provides sufficient precision during practical application. The ultrasonic pulse transit times were measured on beam samples of different asphalt mixtures (semi-dense asphalt concrete AC-S; asphalt concrete for very thin layers BBTM; and porous asphalt PA. The cracks on the laboratory samples were simulated by means of notches of variable depths. With the data of ultrasound transmission time ratios, curve-fittings were carried out on the analytical model, thus determining the regression parameters and their statistical dispersion. The calibrated models obtained from laboratory datasets were subsequently applied to auscultate the evolution of the crack depth after microwaves exposure in the research article entitled “Top-down cracking self-healing of asphalt pavements with steel filler from industrial waste applying microwaves” (Franesqui et al., 2017 [1].

  14. Ultrasound data for laboratory calibration of an analytical model to calculate crack depth on asphalt pavements.

    Science.gov (United States)

    Franesqui, Miguel A; Yepes, Jorge; García-González, Cándida

    2017-08-01

    This article outlines the ultrasound data employed to calibrate in the laboratory an analytical model that permits the calculation of the depth of partial-depth surface-initiated cracks on bituminous pavements using this non-destructive technique. This initial calibration is required so that the model provides sufficient precision during practical application. The ultrasonic pulse transit times were measured on beam samples of different asphalt mixtures (semi-dense asphalt concrete AC-S; asphalt concrete for very thin layers BBTM; and porous asphalt PA). The cracks on the laboratory samples were simulated by means of notches of variable depths. With the data of ultrasound transmission time ratios, curve-fittings were carried out on the analytical model, thus determining the regression parameters and their statistical dispersion. The calibrated models obtained from laboratory datasets were subsequently applied to auscultate the evolution of the crack depth after microwaves exposure in the research article entitled "Top-down cracking self-healing of asphalt pavements with steel filler from industrial waste applying microwaves" (Franesqui et al., 2017) [1].

  15. Node Depth Adjustment Based Target Tracking in UWSNs Using Improved Harmony Search

    Directory of Open Access Journals (Sweden)

    Meiqin Liu

    2017-12-01

    Full Text Available Underwater wireless sensor networks (UWSNs can provide a promising solution to underwater target tracking. Due to the limited computation and bandwidth resources, only a small part of nodes are selected to track the target at each interval. How to improve tracking accuracy with a small number of nodes is a key problem. In recent years, a node depth adjustment system has been developed and applied to issues of network deployment and routing protocol. As far as we know, all existing tracking schemes keep underwater nodes static or moving with water flow, and node depth adjustment has not been utilized for underwater target tracking yet. This paper studies node depth adjustment method for target tracking in UWSNs. Firstly, since a Fisher Information Matrix (FIM can quantify the estimation accuracy, its relation to node depth is derived as a metric. Secondly, we formulate the node depth adjustment as an optimization problem to determine moving depth of activated node, under the constraint of moving range, the value of FIM is used as objective function, which is aimed to be minimized over moving distance of nodes. Thirdly, to efficiently solve the optimization problem, an improved Harmony Search (HS algorithm is proposed, in which the generating probability is modified to improve searching speed and accuracy. Finally, simulation results are presented to verify performance of our scheme.

  16. Chemometric characterization of soil depth profiles

    International Nuclear Information System (INIS)

    Krieg, M.; Einax, J.

    1994-01-01

    The application of multivariate-statistical methods to the description of the metal distribution in soil depth profiles is shown. By means of cluster analysis, it is possible to get a first overview of the main differences in the metal status of the soil horizons. In case of anthropogenic soil pollution or geogenic enrichment, cluster analysis was able to detect the extent of the polluted soil layer or the different geological layers. The results of cluster analysis can be confirmed by means of multidimensional variance and discriminant analysis. Methods of discriminant analysis can also be used as a tool to determine the optimum number of variables which has to be measured for the classification of unknown soil samples into different pollution levels. Factor analysis yields an identification of not directly observable relationships between the variables. With additional knowledge about the orographic situation of the area and the probable sources of emission the factor loadings give information on the immission structure at the sampling location. (orig.)

  17. Ultra-low energy Ar+ beam applied for SIMS depth profile analysis of layered nanostructures

    International Nuclear Information System (INIS)

    Konarski, P.; Mierzejewska, A.; Iwanejko, I.

    2001-01-01

    Secondary ion mass spectrometry (SIMS) depth profile analyses of flat layered nanostructures: 10 nm Ta 2 O 3 /Ta and 20 nm (10 x B 4 C/Mo)/Si as well as microparticles of core (illite) - shell (rutile) structure, performed with the use of ultra-low energy ion beam (180-880 eV, Ar + ), are presented. The profiles were obtained using 'mesa' scanning technique and also sample rotation. Depth profile resolution below 1 nanometer was obtained for flat nanostructures. Presented experimental results are compared with Monte Carlo sputtering simulations of analysed structures. A method of finding beam energy, optimal for the best resolution SIMS depth profile analysis, is suggested. (author)

  18. Full-range k-domain linearization in spectral-domain optical coherence tomography.

    Science.gov (United States)

    Jeon, Mansik; Kim, Jeehyun; Jung, Unsang; Lee, Changho; Jung, Woonggyu; Boppart, Stephen A

    2011-03-10

    A full-bandwidth k-domain linearization method for spectral-domain optical coherence tomography (SD-OCT) is demonstrated. The method uses information of the wavenumber-pixel-position provided by a translating-slit-based wavelength filter. For calibration purposes, the filter is placed either after a broadband source or at the end of the sample path, and the filtered spectrum with a narrowed line width (∼0.5 nm) is incident on a line-scan camera in the detection path. The wavelength-swept spectra are co-registered with the pixel positions according to their central wavelengths, which can be automatically measured with an optical spectrum analyzer. For imaging, the method does not require a filter or a software recalibration algorithm; it simply resamples the OCT signal from the detector array without employing rescaling or interpolation methods. The accuracy of k-linearization is maximized by increasing the k-linearization order, which is known to be a crucial parameter for maintaining a narrow point-spread function (PSF) width at increasing depths. The broadening effect is studied by changing the k-linearization order by undersampling to search for the optimal value. The system provides more position information, surpassing the optimum without compromising the imaging speed. The proposed full-range k-domain linearization method can be applied to SD-OCT systems to simplify their hardware/software, increase their speed, and improve the axial image resolution. The experimentally measured width of PSF in air has an FWHM of 8 μm at the edge of the axial measurement range. At an imaging depth of 2.5 mm, the sensitivity of the full-range calibration case drops less than 10 dB compared with the uncompensated case.

  19. Incoherently combining logarithmic aspheric lenses for extended depth of field.

    Science.gov (United States)

    Chu, Kaiqin; George, Nicholas; Chi, Wanli

    2009-10-01

    We describe a method for combining concentric logarithmic aspheric lenses in order to obtain an extended depth of field. Substantial improvement in extending the depth of field is obtained by carefully controlling the optical path difference among the concentric lenses so that their outputs combine incoherently. The system is analyzed through diffraction theory and the point spread function is shown to be highly invariant over a long range of object distances. After testing the image performance on a three-dimensional scene, we found that the incoherently combined logarithmic aspheres can provide a high-quality image over an axial distance corresponding to a defocus of +/- 14(lambda/4). Studies of the images of two-point objects are presented to illustrate the resolution of these lenses.

  20. Subjective method of refractometry and depth of focus

    OpenAIRE

    Sergienko, Nikolai M.; Gromova, Anastasia; Sergienko, Nikolai

    2012-01-01

    Purpose: To study the impact of the depth of focus on subjective refraction and distribution of myopic and hyperopic refractions. Methods: A total of 450 eyes of 305 subjects in the age range of 23–34 years were recruited for the study. A distribution of refractions was examined using a traditional method of the subjective refractometry on the basis of point-like posterior focus notion. Correction of the results was made on the assumption that the emmetropic eye retains high visual acuity ...

  1. Depth profile analysis of electrodeposited nanoscale multilayers by Secondary Neutral Mass Spectrometry (SNMS)

    International Nuclear Information System (INIS)

    Katona, G.L.; Berenyi, Z.; Vad, K.; Peter, L.

    2006-01-01

    Complete text of publication follows. Nanoscale multilayers have been in the focus of research since the discovery of the giant magnetoresistance (GMR) effect in this family of nanostructures. The first observation of GMR on sputtered magnetic/non-magnetic multilayers was followed by the detection of the same effect in electrodeposited Co-Ni-Cu/Cu multilayers within half a decade. Electrodeposition has long been considered as an inexpensive alternative of the high-vacuum methods to produce multilayers with GMR, although the GMR effect observed for electrodeposited multilayers is usually inferior to multilayers produced by physical methods. Electrochemistry appears to be an exclusive technology to produce multilayered nanowires by using porous templates. In spite of the large number of papers about the multilayers themselves, data on the depth profile of electrodeposited multilayer samples are very scarce. It has long been known that the simultaneous electrodeposition of the iron group metals takes place in the so-called anomalous manner. The diagnostic criterion of the anomalous codeposition is that the metallic component of lower standard potential (the Co in the case of Ni/Co) can be discharged together with the more noble one (Ni) at potentials where the less noble component (Co) alone cannot be deposited onto a substrate composed of the parent metal; moreover, the less noble metal (Co) is deposited preferentially. We have investigated the composition gradient along the growth direction of electrodeposited Co/Cu and CoNiCu/Cu multilayers films using SNMS. Samples were electrodeposited using the single bath method. Commercial Cu sheets and an Cr/Cu layer evaporated onto Si (111) surface were used as substrates with high and low roughness, respectively. The depth profiles of the samples were recorded using SNMS (INA-X, Specs GmbH, Berlin) in the Direct Bombardment Mode. Depth profile analysis of electrodeposited magnetic/nonmagnetic layered structures on

  2. Analysis of LiSn alloy at several depths using LIBS

    Energy Technology Data Exchange (ETDEWEB)

    Suchoňová, M., E-mail: maria.suchonova@fmph.uniba.sk [Dept. of Experimental Physics, Faculty of Mathematics Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F2, 842 48 Bratislava (Slovakia); Krištof, J.; Pribula, M. [Dept. of Experimental Physics, Faculty of Mathematics Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F2, 842 48 Bratislava (Slovakia); Veis, M. [Dept. of Inorganic Chemistry, Faculty of Natural Science, Comenius University, Mlynská dolina, Ilkovičova 6, 842 15 Bratislava 4 (Slovakia); Tabarés, F.L. [Fusion Department, Ciemat, Av Complutense 40, 28040 Madrid (Spain); Veis, P., E-mail: pavel.veis@fmph.uniba.sk [Dept. of Experimental Physics, Faculty of Mathematics Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F2, 842 48 Bratislava (Slovakia)

    2017-04-15

    The difference between the composition of the surface and the inner part of the LiSn sample was studied using Calibration Free Laser Induced Breakdown Spectroscopy (CF-LIBS) method. The sample was analysed under the low pressure (1330 Pa) in Ar atmosphere. The spectra were record using Echelle spectrometer (Mechelle ME5000). Gate delay and gate width was optimised and set to 300 ns. In order to analyse depth profile the LIBS spectra was recorded after each laser shot. The electron density analysed by laser induced plasma was determined separately for each laser shot, which means for each ablated layer of investigated sample. The difference between the individual shots taken at distinct sites of the sample are shown. The CF-LIBS method was used to determine the elemental composition near the surface and in the central part of the LiSn sample.

  3. Vividness and Control of Mental Imagery and the Components of In-Depth Drawing

    Science.gov (United States)

    Pérez-Fabello, María José; Campos, Alfredo; Meana, Juan Carlos

    2014-01-01

    The aim of this study was to examine the associations of control and vividness of mental imagery on performance in several components of in-depth drawing in a sample of fine arts undergraduates. The sample consisted of 56 second-year undergraduates (44 women and 12 men, mean age = 21.18 years) from the Fine Arts Faculty of Vigo University,…

  4. Effects of sample injection amount and time-of-flight mass spectrometric detection dynamic range on metabolome analysis by high-performance chemical isotope labeling LC-MS.

    Science.gov (United States)

    Zhou, Ruokun; Li, Liang

    2015-04-06

    The effect of sample injection amount on metabolome analysis in a chemical isotope labeling (CIL) liquid chromatography-mass spectrometry (LC-MS) platform was investigated. The performance of time-of-flight (TOF) mass spectrometers with and without a high-dynamic-range (HD) detection system was compared in the analysis of (12)C2/(13)C2-dansyl labeled human urine samples. An average of 1635 ± 21 (n = 3) peak pairs or putative metabolites was detected using the HD-TOF-MS, compared to 1429 ± 37 peak pairs from a conventional or non-HD TOF-MS. In both instruments, signal saturation was observed. However, in the HD-TOF-MS, signal saturation was mainly caused by the ionization process, while in the non-HD TOF-MS, it was caused by the detection process. To extend the MS detection range in the non-HD TOF-MS, an automated switching from using (12)C to (13)C-natural abundance peaks for peak ratio calculation when the (12)C peaks are saturated has been implemented in IsoMS, a software tool for processing CIL LC-MS data. This work illustrates that injecting an optimal sample amount is important to maximize the metabolome coverage while avoiding the sample carryover problem often associated with over-injection. A TOF mass spectrometer with an enhanced detection dynamic range can also significantly increase the number of peak pairs detected. In chemical isotope labeling (CIL) LC-MS, relative metabolite quantification is done by measuring the peak ratio of a (13)C2-/(12)C2-labeled peak pair for a given metabolite present in two comparative samples. The dynamic range of peak ratio measurement does not need to be very large, as only subtle changes of metabolite concentrations are encountered in most metabolomic studies where relative metabolome quantification of different groups of samples is performed. However, the absolute concentrations of different metabolites can be very different, requiring a technique to provide a wide detection dynamic range to allow the detection of as

  5. Demonstration/Validation of Incremental Sampling at Two Diverse Military Ranges and Development of an Incremental Sampling Tool

    Science.gov (United States)

    2010-06-01

    Sampling (MIS)? • Technique of combining many increments of soil from a number of points within exposure area • Developed by Enviro Stat (Trademarked...Demonstrating a reliable soil sampling strategy to accurately characterize contaminant concentrations in spatially extreme and heterogeneous...into a set of decision (exposure) units • One or several discrete or small- scale composite soil samples collected to represent each decision unit

  6. Robust calibration of an optical-lattice depth based on a phase shift

    Science.gov (United States)

    Cabrera-Gutiérrez, C.; Michon, E.; Brunaud, V.; Kawalec, T.; Fortun, A.; Arnal, M.; Billy, J.; Guéry-Odelin, D.

    2018-04-01

    We report on a method to calibrate the depth of an optical lattice. It consists of triggering the intrasite dipole mode of the cloud by a sudden phase shift. The corresponding oscillatory motion is directly related to the interband frequencies on a large range of lattice depths. Remarkably, for a moderate displacement, a single frequency dominates the oscillation of the zeroth and first orders of the interference pattern observed after a sufficiently long time of flight. The method is robust against atom-atom interactions and the exact value of the extra weak external confinement superimposed to the optical lattice.

  7. A study on the ranges of low energy ions in biological samples and its mechanism of biological effects

    International Nuclear Information System (INIS)

    Lu Ting; Xie Liqing; Li Junping; Xia Ji

    1993-01-01

    The seeds of wheat and bean are irradiated by iron ion beam with energy 100 keV. The RBS spectra of the samples are observed and the ranges and distributions of the iron ions in the wheat and bean are calculated theoretically by means of Monte Carlo method. The results of theory and experiment are compared and the mechanism of biological effects induced by ion is discussed

  8. Techniques of surface optical breakdown prevention for low-depths femtosecond waveguides writing

    International Nuclear Information System (INIS)

    Bukharin, M A; Skryabin, N N; Ganin, D V; Khudyakov, D V; Vartapetov, S.K.

    2016-01-01

    We demonstrated technique of direct femtosecond waveguide writing at record low depth (2-15 μm) under surface of lithium niobate, that play a key role in design of electrooptical modulators with low operating voltage. To prevent optical breakdown of crystal surface we used high numerical aperture objectives for focusing of light and non-thermal regime of inscription in contrast to widespread femtosecond writing technique at depths of tens micrometers or higher. Surface optical breakdown threshold was measured for both x- and z- cut crystals. Inscribed waveguides were examined for intrinsic microstructure. It also reported sharp narrowing of operating pulses energy range with writing depth under the surface of crystal, that should be taken in account when near-surface waveguides design. Novelty of the results consists in reduction of inscription depth under the surface of crystals that broadens applications of direct femtosecond writing technique to full formation of near-surface waveguides and postproduction precise geometry correction of near-surfaces optical integrated circuits produced with proton-exchanged technique. (paper)

  9. Depth-resolved ballistic imaging in a low-depth-of-field optical Kerr gated imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Yipeng; Tan, Wenjiang, E-mail: tanwenjiang@mail.xjtu.edu.cn; Si, Jinhai; Ren, YuHu; Xu, Shichao; Hou, Xun [Key Laboratory for Physical Electronics and Devices of the Ministry of Education and Shaanxi Key Lab of Information Photonic Technique, School of Electronics and Information Engineering, Xi' an Jiaotong University, Xianning-xilu 28, Xi' an 710049 (China); Tong, Junyi [Departments of Applied Physics, Xi' an University of Technology, Xi' an 710048 (China)

    2016-09-07

    We demonstrate depth-resolved imaging in a ballistic imaging system, in which a heterodyned femtosecond optical Kerr gate is introduced to extract useful imaging photons for detecting an object hidden in turbid media and a compound lens is proposed to ensure both the depth-resolved imaging capability and the long working distance. Two objects of about 15-μm widths hidden in a polystyrene-sphere suspension have been successfully imaged with approximately 600-μm depth resolution. Modulation-transfer-function curves with the object in and away from the object plane have also been measured to confirm the depth-resolved imaging capability of the low-depth-of-field (low-DOF) ballistic imaging system. This imaging approach shows potential for application in research of the internal structure of highly scattering fuel spray.

  10. Quantification of defects depth in glass fiber reinforced plastic plate by infrared lock-in thermography

    Energy Technology Data Exchange (ETDEWEB)

    Ranjit, Shrestha; Kim, Won Tae [Kongju National University, Cheonan (Korea, Republic of); Choi, Man Yong [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2016-03-15

    The increasing use of composite materials in various industries has evidenced the need for development of more effective nondestructive evaluation methodologies in order to reduce rejected parts and to optimize production cost. Infrared thermography is a noncontact, fast and reliable non-destructive evaluation technique that has received vast and growing attention for diagnostic and monitoring in the recent years. This paper describes the quantitative analysis of artificial defects in Glass fiber reinforced plastic plate by using Lockin infrared thermography. The experimental analysis was performed at several excitation frequencies to investigate the sample ranging from 2.946 Hz down to 0.019 Hz and the effects of each excitation frequency on defect detachability. The four point method was used in post processing of every pixel of thermal images using the MATLAB programming language. The relationship between the phase contrast with defects depth and area was examined. Finally, phase contrast method was used to calculate the defects depth considering the thermal diffusivity of the material being inspected and the excitation frequency for which the defect becomes visible. The obtained results demonstrated the effectiveness of Lock-in infrared thermography as a powerful measurement technique for the inspection of Glass fiber reinforced plastic structures.

  11. Determination of 226Ra contamination depth in soil using the multiple photopeaks method

    International Nuclear Information System (INIS)

    Haddad, Kh.; Al-Masri, M.S.; Doubal, A.W.

    2014-01-01

    Radioactive contamination presents a diverse range of challenges in many industries. Determination of radioactive contamination depth plays a vital role in the assessment of contaminated sites, because it can be used to estimate the activity content. It is determined traditionally by measuring the activity distributions along the depth. This approach gives accurate results, but it is time consuming, lengthy and costly. The multiple photopeaks method was developed in this work for 226 Ra contamination depth determination in a NORM contaminated soil using in-situ gamma spectrometry. The developed method bases on linear correlation between the attenuation ratio of different gamma lines emitted by 214 Bi and the 226 Ra contamination depth. Although this method is approximate, but it is much simpler, faster and cheaper than the traditional one. This method can be applied for any case of multiple gamma emitter contaminant. -- Highlights: • The multiple photopeaks method was developed for 226 Ra contamination depth determination using in-situ gamma spectrometry. • The method bases on linear correlation between the attenuation ratio of 214 Bi gamma lines and 226 Ra contamination depth. • This method is simpler, faster and cheaper than the traditional one, it can be applied for any multiple gamma contaminant

  12. Sand moisture as a factor determining depth of burrowing in the ...

    African Journals Online (AJOL)

    Tylos granulatus, a sandy-beach isopod, prefers an environmental moisture range exceeding 3,4% but less than 13%. The depths to which the animals burrow are, at least partly, determined by the moisture gradient in the sand. They are, however, incapable of burrowing into lotally dry sand. Animals alter their position in ...

  13. Curie point depth from spectral analysis of aeromagnetic data for geothermal reconnaissance in Afghanistan

    Science.gov (United States)

    Saibi, H.; Aboud, E.; Gottsmann, J.

    2015-11-01

    The geologic setting of Afghanistan has the potential to contain significant mineral, petroleum and geothermal resources. However, much of the country's potential remains unknown due to limited exploration surveys. Here, we present countrywide aeromagnetic data to estimate the Curie point depth (CPD) and to evaluate the geothermal exploration potential. CPD is an isothermal surface at which magnetic minerals lose their magnetization and as such outlines an isotherm of about 580 °C. We use spectral analysis on the aeromagnetic data to estimate the CPD spatial distribution and compare our findings with known geothermal fields in the western part of Afghanistan. The results outline four regions with geothermal potential: 1) regions of shallow Curie point depths (∼16-21 km) are located in the Helmand basin. 2) regions of intermediate depths (∼21-27 km) are located in the southern Helmand basin and the Baluchistan area. 3) Regions of great depths (∼25-35 km) are located in the Farad block. 4) Regions of greatest depths (∼35-40 km) are located in the western part of the northern Afghanistan platform. The deduced thermal structure in western Afghanistan relates to the collision of the Eurasian and Indian plates, while the shallow CPDs are related to crustal thinning. This study also shows that the geothermal systems are associated with complex magmatic and tectonic association of major intrusions and fault systems. Our results imply geothermal gradients ranging from 14 °C/km to 36 °C/km and heat-flow values ranging from 36 to 90 mW/m2 for the study area.

  14. How Choice of Depth Horizon Influences the Estimated Spatial Patterns and Global Magnitude of Ocean Carbon Export Flux

    Science.gov (United States)

    Palevsky, Hilary I.; Doney, Scott C.

    2018-05-01

    Estimated rates and efficiency of ocean carbon export flux are sensitive to differences in the depth horizons used to define export, which often vary across methodological approaches. We evaluate sinking particulate organic carbon (POC) flux rates and efficiency (e-ratios) in a global earth system model, using a range of commonly used depth horizons: the seasonal mixed layer depth, the particle compensation depth, the base of the euphotic zone, a fixed depth horizon of 100 m, and the maximum annual mixed layer depth. Within this single dynamically consistent model framework, global POC flux rates vary by 30% and global e-ratios by 21% across different depth horizon choices. Zonal variability in POC flux and e-ratio also depends on the export depth horizon due to pronounced influence of deep winter mixing in subpolar regions. Efforts to reconcile conflicting estimates of export need to account for these systematic discrepancies created by differing depth horizon choices.

  15. SU-E-I-92: Accuracy Evaluation of Depth Data in Microsoft Kinect.

    Science.gov (United States)

    Kozono, K; Aoki, M; Ono, M; Kamikawa, Y; Arimura, H; Toyofuku, F

    2012-06-01

    Microsoft Kinect has potential for use in real-time patient position monitoring in diagnostic radiology and radiotherapy. We evaluated the accuracy of depth image data and the device-to-device variation in various conditions simulating clinical applications in a hospital. Kinect sensor consists of infrared-ray depth camera and RGB camera. We developed a computer program using OpenNI and OpenCV for measuring quantitative distance data. The program displays depth image obtained from Kinect sensor on the screen, and the cartesian coordinates at an arbitrary point selected by mouse-clicking can be measured. A rectangular box without luster (300 × 198 × 50 mm 3 ) was used as a measuring object. The object was placed on the floor at various distances ranging from 0 to 400 cm in increments of 10 cm from the sensor, and depth data were measured for 10 points on the planar surface of the box. The measured distance data were calibrated by using the least square method. The device-to-device variations were evaluated using five Kinect sensors. There was almost linear relationship between true and measured values. Kinect sensor was unable to measure at a distance of less than 50 cm from the sensor. It was found that distance data calibration was necessary for each sensor. The device-to-device variation error for five Kinect sensors was within 0.46% at the distance range from 50 cm to 2 m from the sensor. The maximum deviation of the distance data after calibration was 1.1 mm at a distance from 50 to 150 cm. The overall average error of five Kinect sensors was 0.18 mm at a distance range of 50 to 150 cm. Kinect sensor has distance accuracy of about 1 mm if each device is properly calibrated. This sensor will be useable for positioning of patients in diagnostic radiology and radiotherapy. © 2012 American Association of Physicists in Medicine.

  16. The Superficial Dermis May Initiate Keloid Formation: Histological Analysis of the Keloid Dermis at Different Depths

    Directory of Open Access Journals (Sweden)

    Hu Jiao

    2017-11-01

    Full Text Available Several studies have reported on certain aspects of the characteristics of different sites within a keloid lesion, but detailed studies on the keloid dermis at different depths within a keloid lesion are scarce. The aim of this study was to investigate the histology of the keloid dermis at different depths. This study included 19 keloid tissue samples that were collected from 19 patients and 19 normal skin samples, which were harvested from subjects without keloids or hypertrophic scar. Samples were studied by light microscopy using routine hematoxylin and eosin histochemical staining, and immunohistochemistry to detect CD20-positive B-lymphocytes and CD3-positive T-lymphocytes. Sirius Red histochemical staining was used to determine the type of collagen in keloid tissue and normal skin samples. The migratory properties of fibroblasts within the keloid dermis at different depths was compared, using an in vitro migration assay. The findings of this study showed that although the papillary and reticular dermis could be clearly distinguished in normal skin, three tissue layers were identified in the keloid dermis. The superficial dermis of keloid was characterized by active fibroblasts and lymphocytes; the middle dermis contained dense extracellular matrix (ECM with large numbers fibroblasts, and the deep dermis was poorly cellular and characterized by hyalinized collagen bundles. In the keloid samples, from the superficial to the deep dermis, type I collagen increased and type III collagen decreased, and fibroblasts from the superficial dermis of the keloid were found to migrate more rapidly. In conclusion, the findings of this study showed that different depths within the keloid dermis displayed different biological features. The superficial dermis may initiate keloid formation, in which layer intralesional injection of pharmaceuticals and other treatments should be performed for keloid.

  17. Depth-weighted robust multivariate regression with application to sparse data

    KAUST Repository

    Dutta, Subhajit; Genton, Marc G.

    2017-01-01

    A robust method for multivariate regression is developed based on robust estimators of the joint location and scatter matrix of the explanatory and response variables using the notion of data depth. The multivariate regression estimator possesses desirable affine equivariance properties, achieves the best breakdown point of any affine equivariant estimator, and has an influence function which is bounded in both the response as well as the predictor variable. To increase the efficiency of this estimator, a re-weighted estimator based on robust Mahalanobis distances of the residual vectors is proposed. In practice, the method is more stable than existing methods that are constructed using subsamples of the data. The resulting multivariate regression technique is computationally feasible, and turns out to perform better than several popular robust multivariate regression methods when applied to various simulated data as well as a real benchmark data set. When the data dimension is quite high compared to the sample size it is still possible to use meaningful notions of data depth along with the corresponding depth values to construct a robust estimator in a sparse setting.

  18. Depth-weighted robust multivariate regression with application to sparse data

    KAUST Repository

    Dutta, Subhajit

    2017-04-05

    A robust method for multivariate regression is developed based on robust estimators of the joint location and scatter matrix of the explanatory and response variables using the notion of data depth. The multivariate regression estimator possesses desirable affine equivariance properties, achieves the best breakdown point of any affine equivariant estimator, and has an influence function which is bounded in both the response as well as the predictor variable. To increase the efficiency of this estimator, a re-weighted estimator based on robust Mahalanobis distances of the residual vectors is proposed. In practice, the method is more stable than existing methods that are constructed using subsamples of the data. The resulting multivariate regression technique is computationally feasible, and turns out to perform better than several popular robust multivariate regression methods when applied to various simulated data as well as a real benchmark data set. When the data dimension is quite high compared to the sample size it is still possible to use meaningful notions of data depth along with the corresponding depth values to construct a robust estimator in a sparse setting.

  19. Dense range images from sparse point clouds using multi-scale processing

    NARCIS (Netherlands)

    Do, Q.L.; Ma, L.; With, de P.H.N.

    2013-01-01

    Multi-modal data processing based on visual and depth/range images has become relevant in computer vision for 3D reconstruction applications such as city modeling, robot navigation etc. In this paper, we generate highaccuracy dense range images from sparse point clouds to facilitate such

  20. Depth distribution of nitrogen in silicon from plasma ion implantation

    International Nuclear Information System (INIS)

    Vajo, J.J.; Williams, J.D.; Wei, R.; Wilson, R.G.; Matossian, J.N.

    1994-01-01

    Plasma Ion Implantation (PII) is an ion implantation technique that eliminates the line-of-sight restriction of conventional ion-beam implantation and therefore allows for cost effective surface modification of large-scale objects or large-number of small-scale objects. In PII, a part to be implanted is immersed in a low-pressure (10 -4 --10 -5 Torr), partially-ionized plasma that surrounds the part with a plasma sheath. The part is negatively pulse biased up to 100 keV using a repetitive train (100--1,000 Hz) of short-duration (10--40 μsec) voltage pulses. The applied voltage develops across the sheath and accelerates plasma ions into the surface, implanting them omnidirectionally and simultaneously over the entire surface of the part. The depth distribution of the implanted ions influences the extent and type of surface modification achieved and depends upon many factors. These include three rise and fall time of the voltage-pulse waveform, the voltage-pulse amplitude, the ion specie, the ion density, and the temperature of the target. Understanding the contributions to the depth distribution from each of these factors will enable prediction of conditions that will be useful for implantation of large complex parts. To investigate the contributions to the measured depth distributions from these factors nitrogen, predominantly as N + 2 , has been implanted into silicon using PII at 50 and 100 keV (25 and 50 keV per N atom). The implanted depth distributions have been determined using secondary ion mass spectroscopy and Auger electron spectroscopy depth profiling. The distributions differ from the typical, approximately Gaussian, profiles that result from conventional mass selected monoenergetic ion beam implantation. In comparison with ion beam implants and numerical simulations the profiles appear ''filled-in'' with an approximately constant nitrogen concentration for depths less than the expected average ion range

  1. Updating default depths in the ISC bulletin

    Science.gov (United States)

    Bolton, Maiclaire K.; Storchak, Dmitry A.; Harris, James

    2006-09-01

    The International Seismological Centre (ISC) publishes the definitive global bulletin of earthquake locations. In the ISC bulletin, we aim to obtain a free depth, but often this is not possible. Subsequently, the first option is to obtain a depth derived from depth phases. If depth phases are not available, we then use the reported depth from a reputable local agency. Finally, as a last resort, we set a default depth. In the past, common depths of 10, 33, or multiples of 50 km have been assigned. Assigning a more meaningful default depth, specific to a seismic region will increase the consistency of earthquake locations within the ISC bulletin and allow the ISC to publish better positions and magnitude estimates. It will also improve the association of reported secondary arrivals to corresponding seismic events. We aim to produce a global set of default depths, based on a typical depth for each area, from well-constrained events in the ISC bulletin or where depth could be constrained using a consistent set of depth phase arrivals provided by a number of different reporters. In certain areas, we must resort to using other assumptions. For these cases, we use a global crustal model (Crust2.0) to set default depths to half the thickness of the crust.

  2. Moho Depth Variations in the Northeastern North China Craton Revealed by Receiver Function Imaging

    Science.gov (United States)

    Zhang, P.; Chen, L.; Yao, H.; Fang, L.

    2016-12-01

    The North China Craton (NCC), one of the oldest cratons in the world, has attracted wide attention in Earth Science for decades because of the unusual Mesozoic destruction of its cratonic lithosphere. Understanding the deep processes and mechanism of this craton destruction demands detailed knowledge about the deep structure of the region. In this study, we used two-year teleseismic receiver function data from the North China Seismic Array consisting of 200 broadband stations deployed in the northeastern NCC to image the Moho undulation of the region. A 2-D wave equation-based poststack depth migration method was employed to construct the structural images along 19 profiles, and a pseudo 3D crustal velocity model of the region based on previous ambient noise tomography and receiver function study was adopted in the migration. We considered both the Ps and PpPs phases, but in some cases we also conducted PpSs+PsPs migration using different back azimuth ranges of the data, and calculated the travel times of all the considered phases to constrain the Moho depths. By combining the structure images along the 19 profiles, we got a high-resolution Moho depth map beneath the northeastern NCC. Our results broadly consist with the results of previous active source studies [http://www.craton.cn/data], and show a good correlation of the Moho depths with geological and tectonic features. Generally, the Moho depths are distinctly different on the opposite sides of the North-South Gravity Lineament. The Moho in the west are deeper than 40 km and shows a rapid uplift from 40 km to 30 km beneath the Taihang Mountain Range in the middle. To the east in the Bohai Bay Basin, the Moho further shallows to 30-26 km depth and undulates by 3 km, coinciding well with the depressions and uplifts inside the basin. The Moho depth beneath the Yin-Yan Mountains in the north gradually decreases from 42 km in the west to 25 km in the east, varying much smoother than that to the south.

  3. Simulation of range imaging-based estimation of respiratory lung motion. Influence of noise, signal dimensionality and sampling patterns.

    Science.gov (United States)

    Wilms, M; Werner, R; Blendowski, M; Ortmüller, J; Handels, H

    2014-01-01

    A major problem associated with the irradiation of thoracic and abdominal tumors is respiratory motion. In clinical practice, motion compensation approaches are frequently steered by low-dimensional breathing signals (e.g., spirometry) and patient-specific correspondence models, which are used to estimate the sought internal motion given a signal measurement. Recently, the use of multidimensional signals derived from range images of the moving skin surface has been proposed to better account for complex motion patterns. In this work, a simulation study is carried out to investigate the motion estimation accuracy of such multidimensional signals and the influence of noise, the signal dimensionality, and different sampling patterns (points, lines, regions). A diffeomorphic correspondence modeling framework is employed to relate multidimensional breathing signals derived from simulated range images to internal motion patterns represented by diffeomorphic non-linear transformations. Furthermore, an automatic approach for the selection of optimal signal combinations/patterns within this framework is presented. This simulation study focuses on lung motion estimation and is based on 28 4D CT data sets. The results show that the use of multidimensional signals instead of one-dimensional signals significantly improves the motion estimation accuracy, which is, however, highly affected by noise. Only small differences exist between different multidimensional sampling patterns (lines and regions). Automatically determined optimal combinations of points and lines do not lead to accuracy improvements compared to results obtained by using all points or lines. Our results show the potential of multidimensional breathing signals derived from range images for the model-based estimation of respiratory motion in radiation therapy.

  4. Extending the depth of field with chromatic aberration for dual-wavelength iris imaging.

    Science.gov (United States)

    Fitzgerald, Niamh M; Dainty, Christopher; Goncharov, Alexander V

    2017-12-11

    We propose a method of extending the depth of field to twice that achievable by conventional lenses for the purpose of a low cost iris recognition front-facing camera in mobile phones. By introducing intrinsic primary chromatic aberration in the lens, the depth of field is doubled by means of dual wavelength illumination. The lens parameters (radius of curvature, optical power) can be found analytically by using paraxial raytracing. The effective range of distances covered increases with dispersion of the glass chosen and with larger distance for the near object point.

  5. Depth-selective X-ray absorption spectroscopy by detection of energy-loss Auger electrons

    Energy Technology Data Exchange (ETDEWEB)

    Isomura, Noritake, E-mail: isomura@mosk.tytlabs.co.jp [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan); Soejima, Narumasa; Iwasaki, Shiro [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan); Nomoto, Toyokazu; Murai, Takaaki [Aichi Synchrotron Radiation Center (AichiSR), 250-3 Minamiyamaguchi-cho, Seto, Aichi 489-0965 (Japan); Kimoto, Yasuji [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan)

    2015-11-15

    Graphical abstract: - Highlights: • A unique XAS method is proposed for depth profiling of chemical states. • PEY mode detecting energy-loss electrons enables a variation in the probe depth. • Si K-edge XAS spectra of the Si{sub 3}N{sub 4}/SiO{sub 2}/Si multilayer films have been investigated. • Deeper information was obtained in the spectra measured at larger energy loss. • Probe depth could be changed by the selection of the energy of detected electrons. - Abstract: A unique X-ray absorption spectroscopy (XAS) method is proposed for depth profiling of chemical states in material surfaces. Partial electron yield mode detecting energy-loss Auger electrons, called the inelastic electron yield (IEY) mode, enables a variation in the probe depth. As an example, Si K-edge XAS spectra for a well-defined multilayer sample (Si{sub 3}N{sub 4}/SiO{sub 2}/Si) have been investigated using this method at various kinetic energies. We found that the peaks assigned to the layers from the top layer to the substrate appeared in the spectra in the order of increasing energy loss relative to the Auger electrons. Thus, the probe depth can be changed by the selection of the kinetic energy of the energy loss electrons in IEY-XAS.

  6. Depth-selective X-ray absorption spectroscopy by detection of energy-loss Auger electrons

    International Nuclear Information System (INIS)

    Isomura, Noritake; Soejima, Narumasa; Iwasaki, Shiro; Nomoto, Toyokazu; Murai, Takaaki; Kimoto, Yasuji

    2015-01-01

    Graphical abstract: - Highlights: • A unique XAS method is proposed for depth profiling of chemical states. • PEY mode detecting energy-loss electrons enables a variation in the probe depth. • Si K-edge XAS spectra of the Si_3N_4/SiO_2/Si multilayer films have been investigated. • Deeper information was obtained in the spectra measured at larger energy loss. • Probe depth could be changed by the selection of the energy of detected electrons. - Abstract: A unique X-ray absorption spectroscopy (XAS) method is proposed for depth profiling of chemical states in material surfaces. Partial electron yield mode detecting energy-loss Auger electrons, called the inelastic electron yield (IEY) mode, enables a variation in the probe depth. As an example, Si K-edge XAS spectra for a well-defined multilayer sample (Si_3N_4/SiO_2/Si) have been investigated using this method at various kinetic energies. We found that the peaks assigned to the layers from the top layer to the substrate appeared in the spectra in the order of increasing energy loss relative to the Auger electrons. Thus, the probe depth can be changed by the selection of the kinetic energy of the energy loss electrons in IEY-XAS.

  7. A standardized method for sampling and extraction methods for quantifying microplastics in beach sand.

    Science.gov (United States)

    Besley, Aiken; Vijver, Martina G; Behrens, Paul; Bosker, Thijs

    2017-01-15

    Microplastics are ubiquitous in the environment, are frequently ingested by organisms, and may potentially cause harm. A range of studies have found significant levels of microplastics in beach sand. However, there is a considerable amount of methodological variability among these studies. Methodological variation currently limits comparisons as there is no standard procedure for sampling or extraction of microplastics. We identify key sampling and extraction procedures across the literature through a detailed review. We find that sampling depth, sampling location, number of repeat extractions, and settling times are the critical parameters of variation. Next, using a case-study we determine whether and to what extent these differences impact study outcomes. By investigating the common practices identified in the literature with the case-study, we provide a standard operating procedure for sampling and extracting microplastics from beach sand. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Statistically sound evaluation of trace element depth profiles by ion beam analysis

    International Nuclear Information System (INIS)

    Schmid, K.; Toussaint, U. von

    2012-01-01

    This paper presents the underlying physics and statistical models that are used in the newly developed program NRADC for fully automated deconvolution of trace level impurity depth profiles from ion beam data. The program applies Bayesian statistics to find the most probable depth profile given ion beam data measured at different energies and angles for a single sample. Limiting the analysis to % level amounts of material allows one to linearize the forward calculation of ion beam data which greatly improves the computation speed. This allows for the first time to apply the maximum likelihood approach to both the fitting of the experimental data and the determination of confidence intervals of the depth profiles for real world applications. The different steps during the automated deconvolution will be exemplified by applying the program to artificial and real experimental data.

  9. Zooxanthellae of the Montastraea annularis species complex: patterns of distribution of four taxa of Symbiodinium on different reefs and across depths.

    Science.gov (United States)

    Toller, W W; Rowan, R; Knowlton, N

    2001-12-01

    Corals of the Montastraea annularis complex host several different dinoflagellates in the genus Symbiodinium. Here we address two questions arising from our previous studies of these associations on an offshore reef. First, do the same taxa and patterns of association (Symbiodinium A and B found in higher irradiance habitats than Symbiodinium C) occur on an inshore reef? Second, does M. franksi at the limits of its depth range host only Symbiodinium C, as it does at intermediate depths? In both surveys, a new Symbiodinium taxon and different patterns of distribution (assayed by analyses of small ribosomal subunit RNA genes [srDNA]) were observed. Inshore, a taxon we name Symbiodinium E predominated in higher irradiance habitats in M. franksi and its two sibling species; the only other zooxanthella observed was Symbiodinium C. Offshore, M. franksi mainly hosted Symbiodinium C, but hosted Symbiodinium A, B, C, and E in shallow water and Symbiodinium E and C in very deep water. Symbiodinium E may be stress-tolerant. Observed srDNA heterogeneity within samples of Symbiodinium B, C, and E is interpreted as variation across copies within this multigene family. Experimental bleaching of Symbiodinium C supported this interpretation. Thus sequences from natural samples should be interpreted cautiously.

  10. Least limiting water range of Udox soil under degraded pastures on different sun-exposed faces

    Science.gov (United States)

    Passos, Renato Ribeiro; Marciano da Costa, Liovando; Rodrigues de Assis, Igor; Santos, Danilo Andrade; Ruiz, Hugo Alberto; Guimarães, Lorena Abdalla de Oliveira Prata; Andrade, Felipe Vaz

    2017-07-01

    The efficient use of water is increasingly important and proper soil management, within the specificities of each region of the country, allows achieving greater efficiency. The South and Caparaó regions of Espírito Santo, Brazil are characterized by relief of `hill seas' with differences in the degree of pasture degradation due to sun exposure. The objective of this study was to evaluate the least limiting water range in Udox soil under degraded pastures with two faces of exposure to the sun and three pedoenvironments. In each pedoenvironment, namely Alegre, Celina, and Café, two areas were selected, one with exposure on the North/West face and the other on the South/East face. In each of these areas, undisturbed soil samples were collected at 0-10 cm depth to determine the least limiting water range. The exposed face of the pasture that received the highest solar incidence (North/West) presented the lowest values in least limiting water range. The least limiting water range proved to be a physical quality indicator for Udox soil under degraded pastures.

  11. Long range echo classification for minehunting sonars

    NARCIS (Netherlands)

    Theije, P.A.M. de; Groen, J.; Sabel, J.C.

    2006-01-01

    This paper focesus on single-ping classification of sea mines, at a range of about 400 m, and combining a hull mounted sonar (HMS) and a propelled variable-depth sonar (PDVS). The deleoped classifier is trained and tested on a set of simulated realistic echoes of mines and non-mines. As the mines

  12. Effects of prescription depth, cylinder size, treatment length, tip space, and curved end on doses in high-dose-rate vaginal brachytherapy

    International Nuclear Information System (INIS)

    Li Shidong; Aref, Ibrahim; Walker, Eleanor; Movsas, Benjamin

    2007-01-01

    Purpose: To determine the effects of the prescription depth, cylinder size, treatment length, tip space, and curved end on high-dose-rate vaginal brachytherapy (HDR-VBT) of endometrial cancer. Methods and Materials: Treatment plans were prescribed and optimized based on points at the cylinder surface or at 0.5-cm depth. Cylinder sizes ranging from 2 to 4 cm in diameter, and treatment lengths ranging from 3 to 8 cm were used. Dose points in various depths were precisely defined along the cylinder dome. The given dose and dose uniformity to a depth of interest were measured by the mean dose (MD) and standard deviation (SD), respectively, among the dose points belonging to the depth. Dose fall-off beyond the 0.5 cm treatment depth was determined by the ratio of MD at 0.75-cm depth to MD at 0.5-cm depth. Results: Dose distribution varies significantly with different prescriptions. The surface prescription provides more uniform doses at all depths in the target volume, whereas the 0.5-cm depth prescription creates larger dose variations at the cylinder surface. Dosimetric uncertainty increases significantly (>30%) with shorter tip space. Extreme hot (>150%) and cold spots (<60%) occur if no optimization points were placed at the curved end. Conclusions: Instead of prescribing to a depth of 0.5 cm, increasing the dose per fraction and prescribing to the surface with the exact surface points around the cylinder dome appears to be the optimal approach

  13. Evidence for large compositional ranges in coeval melts erupted from Kīlauea's summit reservoir: Chapter 7

    Science.gov (United States)

    Helz, Rosalind T.; Clague, David A.; Mastin, Larry G.; Rose, Timothy R.; Carey, Rebecca; Cayol, Valérie; Poland, Michael P.; Weis, Dominique

    2015-01-01

    Petrologic observations on Kīlauea's lavas include abundant microprobe analyses of glasses, which show the range of melts available in Kīlauea's summit reservoir over time. During the past two centuries, compositions of melts erupted within the caldera have been limited to MgO = 6.3–7.5 wt%. Extracaldera lavas of the 1959, 1971, and 1974 eruptions contain melts with up to 10.2, 8.9, and 9.2 wt% MgO, respectively, and the 1924 tephra contains juvenile Pele's tears with up to 9.1 wt% MgO. Melt compositions from explosive deposits at Kīlauea, including the Keanakāko‘i (A.D. 1500–1800), Kulanaokuaiki (A.D. 400–1000), and Pāhala (10–25 ka) tephra units, show large ranges of MgO contents. The range of melt MgO is 6.5–11.0 wt% for the Keanakāko‘i; the Kulanaokuaiki extends to 12.5% MgO and the Pāhala Ash includes rare shards with 13–14.5% MgO. The frequency distributions for MgO in the Keanakāko‘i and Kulanaokuaiki glasses are bimodal, suggesting preferential magma storage at two different depths. Kīlauea's summit reservoir contains melts ranging from 6.5 to at least 11.0 wt% MgO, and such melts were available for sampling near instantaneously and repeatedly over centuries. More magnesian melts are inferred to have risen directly from greater depth.

  14. Real-time lossless compression of depth streams

    KAUST Repository

    Schneider, Jens

    2017-08-17

    Various examples are provided for lossless compression of data streams. In one example, a Z-lossless (ZLS) compression method includes generating compacted depth information by condensing information of a depth image and a compressed binary representation of the depth image using histogram compaction and decorrelating the compacted depth information to produce bitplane slicing of residuals by spatial prediction. In another example, an apparatus includes imaging circuitry that can capture one or more depth images and processing circuitry that can generate compacted depth information by condensing information of a captured depth image and a compressed binary representation of the captured depth image using histogram compaction; decorrelate the compacted depth information to produce bitplane slicing of residuals by spatial prediction; and generate an output stream based upon the bitplane slicing.

  15. Real-time lossless compression of depth streams

    KAUST Repository

    Schneider, Jens

    2017-01-01

    Various examples are provided for lossless compression of data streams. In one example, a Z-lossless (ZLS) compression method includes generating compacted depth information by condensing information of a depth image and a compressed binary representation of the depth image using histogram compaction and decorrelating the compacted depth information to produce bitplane slicing of residuals by spatial prediction. In another example, an apparatus includes imaging circuitry that can capture one or more depth images and processing circuitry that can generate compacted depth information by condensing information of a captured depth image and a compressed binary representation of the captured depth image using histogram compaction; decorrelate the compacted depth information to produce bitplane slicing of residuals by spatial prediction; and generate an output stream based upon the bitplane slicing.

  16. Test plan for evaluating the operational performance of the prototype nested, fixed-depth fluidic sampler

    International Nuclear Information System (INIS)

    REICH, F.R.

    1999-01-01

    The PHMC will provide Low Activity Wastes (LAW) tank wastes for final treatment by a privatization contractor from two double-shell feed tanks, 241-AP-102 and 241-AP-104. Concerns about the inability of the baseline ''grab'' sampling to provide large volume samples within time constraints has led to the development of a nested, fixed-depth sampling system. This sampling system will provide large volume, representative samples without the environmental, radiation exposure, and sample volume impacts of the current base-line ''grab'' sampling method. A plan has been developed for the cold testing of this nested, fixed-depth sampling system with simulant materials. The sampling system will fill the 500-ml bottles and provide inner packaging to interface with the Hanford Sites cask shipping systems (PAS-1 and/or ''safe-send''). The sampling system will provide a waste stream that will be used for on-line, real-time measurements with an at-tank analysis system. The cold tests evaluate the performance and ability to provide samples that are representative of the tanks' content within a 95 percent confidence interval, to sample while mixing pumps are operating, to provide large sample volumes (1-15 liters) within a short time interval, to sample supernatant wastes with over 25 wt% solids content, to recover from precipitation- and settling-based plugging, and the potential to operate over the 20-year expected time span of the privatization contract

  17. Depth- and range-dependent variation in the performance of aquatic telemetry systems: understanding and predicting the susceptibility of acoustic tag–receiver pairs to close proximity detection interference

    Directory of Open Access Journals (Sweden)

    Stephen R. Scherrer

    2018-01-01

    Full Text Available Background Passive acoustic telemetry using coded transmitter tags and stationary receivers is a popular method for tracking movements of aquatic animals. Understanding the performance of these systems is important in array design and in analysis. Close proximity detection interference (CPDI is a condition where receivers fail to reliably detect tag transmissions. CPDI generally occurs when the tag and receiver are near one another in acoustically reverberant settings. Here we confirm transmission multipaths reflected off the environment arriving at a receiver with sufficient delay relative to the direct signal cause CPDI. We propose a ray-propagation based model to estimate the arrival of energy via multipaths to predict CPDI occurrence, and we show how deeper deployments are particularly susceptible. Methods A series of experiments were designed to develop and validate our model. Deep (300 m and shallow (25 m ranging experiments were conducted using Vemco V13 acoustic tags and VR2-W receivers. Probabilistic modeling of hourly detections was used to estimate the average distance a tag could be detected. A mechanistic model for predicting the arrival time of multipaths was developed using parameters from these experiments to calculate the direct and multipath path lengths. This model was retroactively applied to the previous ranging experiments to validate CPDI observations. Two additional experiments were designed to validate predictions of CPDI with respect to combinations of deployment depth and distance. Playback of recorded tags in a tank environment was used to confirm multipaths arriving after the receiver’s blanking interval cause CPDI effects. Results Analysis of empirical data estimated the average maximum detection radius (AMDR, the farthest distance at which 95% of tag transmissions went undetected by receivers, was between 840 and 846 m for the deep ranging experiment across all factor permutations. From these results, CPDI was

  18. Measurements of europium-152 depth profile of stone embankments exposed the Nagasaki atomic bomb for neutron spectrum analysis

    International Nuclear Information System (INIS)

    Tatsumi-Miyajima, Junko; Shimasaki, Tatsuya; Okajima, Shunzo; Takada, Jitsuya; Yoshida, Masahiro; Takao, Hideaki; Okumura, Yutaka; Nakazawa, Masaharu.

    1990-01-01

    Quantitative measurement of neutron-induced radionuclide of 152 Eu in rocks near the hypocenter (ground center of the atomic bomb explosion) in Nagasaki was performed to obtain the depth profiles and calculate the neutron energy spectrum. Core samples were drilled and taken from the stone embankments on both sides of river within a radius of 500 m from the hypocenter. After cutting each core into about 27 mm-thick sections, each section was measured its gamma-ray spectrum with a pure germanium semiconductor detector and analyzed a content of natural europium by the activation method. The highest value 8.0 x 10 -2 Bq/μg of 152 Eu at the time of the blast was obtained from the surface plates of rock cores collected near the hypocenter. The surface activity of cores was reduced with increasing the slant distances from the hypocenter. The slopes of the depth profiles were similar among samples taken from the same location. In order to analyze the depth profile of 152 Eu activity in rock andesite, experiments using a fast neutron reactor and thermal neutron reactor were carried out. Comparing the measurements on the A-bomb exposure rock with the simulated results at the reactors, among the experiments, the depth profile using the neutron moderator of 10 mm polyethylene was closed to that obtained from the A-bomb exposed samples. The experiment of thermal neutron incidence only could not reproduce the profiles from the A-bomb exposed samples. This fact indicates that the depth profiles of 152 Eu in rock exposed to the A-bomb include valuable information concerning the neutron spectrum and intensity. (author)

  19. Quantitative evaluation of sputtering induced surface roughness and its influence on AES depth profiles of polycrystalline Ni/Cu multilayer thin films

    Energy Technology Data Exchange (ETDEWEB)

    Yan, X.L.; Coetsee, E. [Department of Physics, University of the Free State, P O Box 339, Bloemfontein, ZA9300 (South Africa); Wang, J.Y., E-mail: wangjy@stu.edu.cn [Department of Physics, Shantou University, 243 Daxue Road, Shantou, 515063, Guangdong (China); Swart, H.C., E-mail: swartHC@ufs.ac.za [Department of Physics, University of the Free State, P O Box 339, Bloemfontein, ZA9300 (South Africa); Terblans, J.J., E-mail: terblansjj@ufs.ac.za [Department of Physics, University of the Free State, P O Box 339, Bloemfontein, ZA9300 (South Africa)

    2017-07-31

    Highlights: • Linear Least Square (LLS) method used to separate Ni and Cu Auger spectra. • The depth-dependent ion sputtering induced roughness was quantitatively evaluated. • The depth resolution better when profiling with dual-ion beam vs. a single-ion beam. • AES depth profiling with a lower ion energy results in a better depth resolution. - Abstract: The polycrystalline Ni/Cu multilayer thin films consisting of 8 alternating layers of Ni and Cu were deposited on a SiO{sub 2} substrate by means of electron beam evaporation in a high vacuum. Concentration-depth profiles of the as-deposited multilayered Ni/Cu thin films were determined with Auger electron spectroscopy (AES) in combination with Ar{sup +} ion sputtering, under various bombardment conditions with the samples been stationary as well as rotating in some cases. The Mixing-Roughness-Information depth (MRI) model used for the fittings of the concentration-depth profiles accounts for the interface broadening of the experimental depth profiling. The interface broadening incorporates the effects of atomic mixing, surface roughness and information depth of the Auger electrons. The roughness values extracted from the MRI model fitting of the depth profiling data agrees well with those measured by atomic force microscopy (AFM). The ion sputtering induced surface roughness during the depth profiling was accordingly quantitatively evaluated from the fitted MRI parameters with sample rotation and stationary conditions. The depth resolutions of the AES depth profiles were derived directly from the values determined by the fitting parameters in the MRI model.

  20. EPA Region 1 - Valley Depth in Meters

    Science.gov (United States)

    Raster of the Depth in meters of EPA-delimited Valleys in Region 1.Valleys (areas that are lower than their neighbors) were extracted from a Digital Elevation Model (USGS, 30m) by finding the local average elevation, subtracting the actual elevation from the average, and selecting areas where the actual elevation was below the average. The landscape was sampled at seven scales (circles of 1, 2, 4, 7, 11, 16, and 22 km radius) to take into account the diversity of valley shapes and sizes. Areas selected in at least four scales were designated as valleys.

  1. Analysis of influence of different pressure and different depth of pvd on soft foundation treatment

    Science.gov (United States)

    Li, Bin; Wang, XueKui

    2018-02-01

    According to the depth of plastic vertical drainage (pvd), the arrangement mode and the loading mode to analyze the influence of Vacuum preloading near the existing road. An arrangement mode of vacuum preloading to reduce the impact was put forward. The combination of different depth of pvd and loading modes are used to analyze the effect of vacuum preloading treatment and its influence range. The calculations show that the deformation and the influence distance are smaller by using the 40kPa vacuum loading and 41kPa surcharge load preloading. Reducing the depth of the pvd and vacuum combined surcharge preloading can weaken the influence to the existing highway.

  2. Long range implantation by MEVVA metal ion source

    International Nuclear Information System (INIS)

    Zhang Tonghe; Wu Yuguang; Ma Furong; Liang Hong

    2001-01-01

    Metal vapor vacuum arc (MEVVA) source ion implantation is a new technology used for achieving long range ion implantation. It is very important for research and application of the ion beam modification of materials. The results show that the implanted atom diffusion coefficient increases in Mo implanted Al with high ion flux and high dose. The implanted depth is 311.6 times greater than that of the corresponding ion range. The ion species, doses and ion fluxes play an important part in the long-range implantation. Especially, thermal atom chemistry have specific effect on the long-range implantation during high ion flux implantation at transient high target temperature

  3. Basin and Range Province, Western US, USGS Grids #2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These grid files were used to produce gravity and basin depth maps of the Basin and Range Province, western United States. The maps show gravity values and modeled...

  4. Basin and Range Province, Western US, USGS Grids, #1

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These grid files were used to produce gravity and basin depth maps of the Basin and Range Province, western United States. The maps show gravity values and modeled...

  5. Basin and Range Province, Western US, USGS Grids #3

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These grid files were used to produce gravity and basin depth maps of the Basin and Range Province, western United States. The maps show gravity values and modeled...

  6. Basin and Range Province, Western US, USGS Grids #5

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These grid files were used to produce gravity and basin depth maps of the Basin and Range Province, western United States. The maps show gravity values and modeled...

  7. Basin and Range Province, Western US, USGS Grids #4

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These grid files were used to produce gravity and basin depth maps of the Basin and Range Province, western United States. The maps show gravity values and modeled...

  8. Identification of Chinese medicinal fungus Cordyceps sinensis by depth-profiling mid-infrared photoacoustic spectroscopy

    Science.gov (United States)

    Du, Changwen; Zhou, Jianmin; Liu, Jianfeng

    2017-02-01

    With increased demand for Cordyceps sinensis it needs rapid methods to meet the challenge of identification raised in quality control. In this study Cordyceps sinensis from four typical natural habitats in China was characterized by depth-profiling Fourier transform infrared photoacoustic spectroscopy. Results demonstrated that Cordyceps sinensis samples resulted in typical photoacoustic spectral appearance, but heterogeneity was sensed in the whole sample; due to the heterogeneity Cordyceps sinensis was represented by spectra of four groups including head, body, tail and leaf under a moving mirror velocity of 0.30 cm s- 1. The spectra of the four groups were used as input of a probabilistic neural network (PNN) to identify the source of Cordyceps sinensis, and all the samples were correctly identified by the PNN model. Therefore, depth-profiling Fourier transform infrared photoacoustic spectroscopy provides novel and unique technique to identify Cordyceps sinensis, which shows great potential in quality control of Cordyceps sinensis.

  9. Calculating depths to shallow magnetic sources using aeromagnetic data from the Tucson Basin

    Science.gov (United States)

    Casto, Daniel W.

    2001-01-01

    Using gridded high-resolution aeromagnetic data, the performance of several automated 3-D depth-to-source methods was evaluated over shallow control sources based on how close their depth estimates came to the actual depths to the tops of the sources. For all three control sources, only the simple analytic signal method, the local wavenumber method applied to the vertical integral of the magnetic field, and the horizontal gradient method applied to the pseudo-gravity field provided median depth estimates that were close (-11% to +14% error) to the actual depths. Careful attention to data processing was required in order to calculate a sufficient number of depth estimates and to reduce the occurrence of false depth estimates. For example, to eliminate sampling bias, high-frequency noise and interference from deeper sources, it was necessary to filter the data before calculating derivative grids and subsequent depth estimates. To obtain smooth spatial derivative grids using finite differences, the data had to be gridded at intervals less than one percent of the anomaly wavelength. Before finding peak values in the derived signal grids, it was necessary to remove calculation noise by applying a low-pass filter in the grid-line directions and to re-grid at an interval that enabled the search window to encompass only the peaks of interest. Using the methods that worked best over the control sources, depth estimates over geologic sites of interest suggested the possible occurrence of volcanics nearly 170 meters beneath a city landfill. Also, a throw of around 2 kilometers was determined for a detachment fault that has a displacement of roughly 6 kilometers.

  10. A comparison of mixing depths observed over horizontally inhomogeneous terrain

    Energy Technology Data Exchange (ETDEWEB)

    White, A.B. [Univ. of Colorado/NOAA Environmental Technology Lab., Cooperative Inst. for Research in Environmental Sciences, Boulder, CO (United States); King, C.W. [NOAA Environmental Technology Lab., Boulder, CO (United States)

    1997-10-01

    In this paper we used wind profiler observations to estimate the mixing depth on either side of the Continental Divide on days when a PTBC (plain-to-basin-circulation) occurred along the Front Range of Colorado during the summer of 1995. The mixing depths on the basin side were significantly deeper than the mountain barrier for all of the PTBC events we analyzed. On the plains side, the mixed layers often extended to or above the level of the mountain barrier. On certain days up-slope flow existed above the mixed layer. We depicted the vertical structure of the flow and features in the humidity profile on one of these days using measurements from a wind profiler. The results were consistent with the conceptual model presented by Wolyn and McKee (1994). (au)

  11. Distribution of meiobenthos at bathyal depths in the Mediterranean Sea. A comparison between sites of contrasting productivity

    Directory of Open Access Journals (Sweden)

    Anastasios Tselepides

    2004-12-01

    Full Text Available In order to study the distribution of meiobenthos (Metazoa and Foraminifera at bathyal depths along a west-east productivity gradient in the Mediterranean Sea, stations along the continental slopes of the Balearic Sea, west Ionian and east Ionian Seas were sampled during the DESEAS Trans-Mediterranean Cruise in June-July 2001. Standing stock of total meiobenthos differed considerably among the sampling stations, with marked differences occurring between sampling depths and sites. At 600 m depth, meiobenthic abundances were slightly higher over the Balearic continental slope, whereas at the deeper stations (800 m and 1500-1700 m, abundances were significantly higher in the west Ionian Sea. Significant relationships were found between the abundances of major groups and the chloroplastic pigments, indicating that food availability is a major factor controlling the distribution of meiobenthos. Apart from the overall differences in productivity between the western and eastern Mediterranean Sea, local hydrographic features and topographic differences greatly influence the spatial variability of the environmental parameters within each sub-basin and thus the distribution of meiobenthos in the bathyal zone.

  12. Wave Loads on Ships Sailing in Restricted Water Depth

    DEFF Research Database (Denmark)

    Vidic-Perunovic, Jelena; Jensen, Jørgen Juncher

    2003-01-01

    depth for a container vessel. The results show that if the water depth is less than two times the draft of the vessel, the wave-induced bending moment becomes significant larger than in deep water with the same sea state description. The peak in the frequency response function for the wave bending......The wave-induced bending moment in ships is the most important sea load parameter for ships larger than 100m in length. Hence, any rational ship design procedure must include a reasonable accurate determination of this load and a large amount of various hydrodynamic formulations have been published......, ranging from semi-empirical formulas to three-dimensional non-linear procedures. A review of the state-of-the art can be found in ISSC.VI.1 (2000). These procedures must be combined with operational and sea state information to predict the probability distribution of the maximum wave-induced bending...

  13. Prediction of lake depth across a 17-state region in the United States

    Science.gov (United States)

    Oliver, Samantha K.; Soranno, Patricia A.; Fergus, C. Emi; Wagner, Tyler; Winslow, Luke A.; Scott, Caren E.; Webster, Katherine E.; Downing, John A.; Stanley, Emily H.

    2016-01-01

    Lake depth is an important characteristic for understanding many lake processes, yet it is unknown for the vast majority of lakes globally. Our objective was to develop a model that predicts lake depth using map-derived metrics of lake and terrestrial geomorphic features. Building on previous models that use local topography to predict lake depth, we hypothesized that regional differences in topography, lake shape, or sedimentation processes could lead to region-specific relationships between lake depth and the mapped features. We therefore used a mixed modeling approach that included region-specific model parameters. We built models using lake and map data from LAGOS, which includes 8164 lakes with maximum depth (Zmax) observations. The model was used to predict depth for all lakes ≥4 ha (n = 42 443) in the study extent. Lake surface area and maximum slope in a 100 m buffer were the best predictors of Zmax. Interactions between surface area and topography occurred at both the local and regional scale; surface area had a larger effect in steep terrain, so large lakes embedded in steep terrain were much deeper than those in flat terrain. Despite a large sample size and inclusion of regional variability, model performance (R2 = 0.29, RMSE = 7.1 m) was similar to other published models. The relative error varied by region, however, highlighting the importance of taking a regional approach to lake depth modeling. Additionally, we provide the largest known collection of observed and predicted lake depth values in the United States.

  14. Layered compression for high-precision depth data.

    Science.gov (United States)

    Miao, Dan; Fu, Jingjing; Lu, Yan; Li, Shipeng; Chen, Chang Wen

    2015-12-01

    With the development of depth data acquisition technologies, access to high-precision depth with more than 8-b depths has become much easier and determining how to efficiently represent and compress high-precision depth is essential for practical depth storage and transmission systems. In this paper, we propose a layered high-precision depth compression framework based on an 8-b image/video encoder to achieve efficient compression with low complexity. Within this framework, considering the characteristics of the high-precision depth, a depth map is partitioned into two layers: 1) the most significant bits (MSBs) layer and 2) the least significant bits (LSBs) layer. The MSBs layer provides rough depth value distribution, while the LSBs layer records the details of the depth value variation. For the MSBs layer, an error-controllable pixel domain encoding scheme is proposed to exploit the data correlation of the general depth information with sharp edges and to guarantee the data format of LSBs layer is 8 b after taking the quantization error from MSBs layer. For the LSBs layer, standard 8-b image/video codec is leveraged to perform the compression. The experimental results demonstrate that the proposed coding scheme can achieve real-time depth compression with satisfactory reconstruction quality. Moreover, the compressed depth data generated from this scheme can achieve better performance in view synthesis and gesture recognition applications compared with the conventional coding schemes because of the error control algorithm.

  15. A method of increasing the depth of the plastically deformed layer in the roller burnishing process

    Science.gov (United States)

    Kowalik, Marek; Trzepiecinski, Tomasz

    2018-05-01

    The subject of this paper is an analysis of the determination of the depth of the plastically deformed layer in the process of roller burnishing a shaft using a newly developed method in which a braking moment is applied to the roller. It is possible to increase the depth of the plastically deformed layer by applying the braking moment to the roller during the burnishing process. The theoretical considerations presented are based on the Hertz-Bielayev and Huber-Mises theories and permit the calculation of the depth of plastic deformation of the top layer of the burnished shaft. The theoretical analysis has been verified experimentally and using numerical calculations based on the finite element method using the Msc.MARC program. Experimental tests were carried out on ring-shaped samples made of C45 carbon steel. The samples were burnished at different values of roller force and different values of braking moment. A significant increase was found in the depth of the plastically deformed surface layer of roller burnished shafts. Usage of the phenomenon of strain hardening of steel allows the technology presented here to increase the fatigue life of the shafts.

  16. Novel Method for Sizing Metallic Bottom Crack Depth Using Multi-frequency Alternating Current Potential Drop Technique

    Directory of Open Access Journals (Sweden)

    Li Yuting

    2015-10-01

    Full Text Available Potential drop techniques are of two types: the direct current potential drop (DCPD technique and alternating current potential drop (ACPD technique, and both of them are used in nondestructive testing. ACPD, as a kind of valid method in sizing metal cracks, has been applied to evaluate metal structures. However, our review of most available approaches revealed that some improvements can be done in measuring depth of metal bottom crack by means of ACPD, such as accuracy and sensitivity of shallow crack. This paper studied a novel method which utilized the slope of voltage ratio-frequency curve to solve bottom crack depth by using a simple mathematic equation based on finite element analysis. It is found that voltage ratio varies linearly with frequency in the range of 5-15 Hz; this range is slightly higher than the equivalent frequency and lower than semi-permeable frequency. Simulation and experiment show that the novel method can measure the bottom crack depth accurately.

  17. Novel Method for Sizing Metallic Bottom Crack Depth Using Multi-frequency Alternating Current Potential Drop Technique

    Science.gov (United States)

    Li, Yuting; Gan, Fangji; Wan, Zhengjun; Liao, Junbi; Li, Wenqiang

    2015-10-01

    Potential drop techniques are of two types: the direct current potential drop (DCPD) technique and alternating current potential drop (ACPD) technique, and both of them are used in nondestructive testing. ACPD, as a kind of valid method in sizing metal cracks, has been applied to evaluate metal structures. However, our review of most available approaches revealed that some improvements can be done in measuring depth of metal bottom crack by means of ACPD, such as accuracy and sensitivity of shallow crack. This paper studied a novel method which utilized the slope of voltage ratio-frequency curve to solve bottom crack depth by using a simple mathematic equation based on finite element analysis. It is found that voltage ratio varies linearly with frequency in the range of 5-15 Hz; this range is slightly higher than the equivalent frequency and lower than semi-permeable frequency. Simulation and experiment show that the novel method can measure the bottom crack depth accurately.

  18. In-depth imaging and quantification of degenerative changes associated with Achilles ruptured tendons by polarization-sensitive optical coherence tomography

    International Nuclear Information System (INIS)

    Bagnaninchi, P O; Yang, Y; Maffulli, G; El Haj, A; Maffulli, N; Bonesi, M; Meglinski, I; Phelan, C

    2010-01-01

    The objective of this study was to develop a method based on polarization-sensitive optical coherent tomography (PSOCT) for the imaging and quantification of degenerative changes associated with Achilles tendon rupture. Ex vivo PSOCT examinations were performed in 24 patients. The study involved samples from 14 ruptured Achilles tendons, 4 tendinopathic Achilles tendons and 6 patellar tendons (collected during total knee replacement) as non-ruptured controls. The samples were imaged in both intensity and phase retardation modes within 24 h after surgery, and birefringence was quantified. The samples were fixed and processed for histology immediately after imaging. Slides were assessed twice in a blind manner to provide a semi-quantitative histological score of degeneration. In-depth micro structural imaging was demonstrated. Collagen disorganization and high cellularity were observable by PSOCT as the main markers associated with pathological features. Quantitative assessment of birefringence and penetration depth found significant differences between non-ruptured and ruptured tendons. Microstructure abnormalities were observed in the microstructure of two out of four tendinopathic samples. PSOCT has the potential to explore in situ and in-depth pathological change associated with Achilles tendon rupture, and could help to delineate abnormalities in tendinopathic samples in vivo.

  19. Major- and trace elements in grain size fractions of the Apollo-17 core of the drilled sample 74001

    International Nuclear Information System (INIS)

    Kraehenbuehl, U.; Gunten, H.R. von; Jost, D.; Meyer, G.; Wegmueller, F.

    1980-01-01

    Two layers of a drill sample were examined, one from a depth of 38 cm and the other from 58 cm depth. Neutron activation analysis was used for one group of elements, and radiochemical analysis for another. Over a range of grain size from 36 to 450 μm, the trace elements U, Co, and La were found to uniformly distributed, as was iron. The top layer consistently showed a 5-8% higher content. The volatile trace elements Ge and Cd were found to be enriched in the smaller grain sizes. This contradicts previous assumptions of an enrichment of the more volatile elements in top layers owing to more rapid cooling of volcanic eruptions. (R.S.)

  20. Infrared surface analysis using a newly developed thin-sample preparation system.

    Science.gov (United States)

    Nagai, Naoto; Nishiyama, Itsuo; Kishima, Yoshio; Iida, Katsuhiko; Mori, Koichi

    2009-01-01

    We developed a new sampling system, the Nano Catcher, for measuring the surface chemical structure of polymers or industrial products and we evaluated the performance of the system. The system can directly pick up surface species whose depth is on the order of approximately 100 nm and can easily provide a sample for a Fourier transform infrared (FT-IR) system without the necessity of passing it over to a measurement plate. The FT-IR reflection data obtained from the Nano Catcher were compared with those obtained using the attenuated total reflection (ATR) method and sampling by hand. Chemical structural analysis of a depth region from a few tens of nanometers to a few hundred nanometers can be directly performed using this system. Such depths are beyond the scope of conventional X-ray photoelectron spectroscopy (XPS) and ATR methods. We can expect the use of the Nano Catcher system to lead to a great improvement in the detection of signals of surface species in these depth regions.

  1. A study on 210Po activity concentration in soil at different depths along coastal Kerala

    International Nuclear Information System (INIS)

    Primal D'Cunha; Sathyanarayana Bhat, P.; Narayana, Y.

    2011-01-01

    The paper presents systematic studies on the vertical profiles of 210 Po, an important decay product of 238 U, in soils along coastal Kerala. Soil samples collected from different depth intervals 0-10, 10-20, 20-30 cm were analyzed for 210 Po activity concentration by radiochemical methods. The activity 210 Po in soil samples were counted using a ZnS(Ag) alpha scintillation counting system. The mean values of activity concentrations of 210 Po in soil of various depths were found to be 8.66, 5.63 and 4.95 Bq kg -1 for depth intervals of 0-10, 10-20 and 20-30 cm, respectively. The overall activity concentration of 210 Po in soil was found to vary from 2.26 ± 0.19 to 14.02 ± 0.12 Bq kg -1 with a mean value of 6.43 Bq kg -1 . Maximum activity concentration was found in soil samples of Kollam region with the mean value of 10.08 ± 0.92 Bq kg -1 . The activity of 210 Po was found to be comparatively high in surface soil. The variation of 210 Po activity concentration with organic matter contents was studied. 210 Polonium activity concentration was found to increase with increasing organic matter content. (author)

  2. RAPID DETERMINATION OF FOCAL DEPTH USING A GLOBAL NETWORK OF SMALL-APERTURE SEISMIC ARRAYS

    Science.gov (United States)

    Seats, K.; Koper, K.; Benz, H.

    2009-12-01

    The National Earthquake Information Center (NEIC) of the United States Geological Survey (USGS) operates 24 hours a day, 365 days a year with the mission of locating and characterizing seismic events around the world. A key component of this task is quickly determining the focal depth of each seismic event, which has a first-order effect on estimates of ground shaking used in the impact assessment applications of emergency response activities. Current methods of depth estimation used at the NEIC include arrival time inversion both with and without depth phases, a Bayesian depth constraint based on historical seismicity (1973-present), and moment tensor inversion primarily using P- and S-wave waveforms. In this study, we explore the possibility of automated modeling of waveforms from vertical-component arrays of the International Monitoring System (IMS) to improve rapid depth estimation at NEIC. Because these arrays are small-aperture, they are effective at increasing signal to noise ratios for frequencies of 1 Hz and higher. Currently, NEIC receives continuous real-time data from 23 IMS arrays. Following work done by previous researchers, we developed a technique that acts as an array of arrays. For a given epicentral location we calculate fourth root beams for each IMS array in the distance range of 30 to 95 degrees at the expected slowness vector of the first arrival. Because the IMS arrays are small-aperture, these beams highlight energy that has slowness similar to the first arrival, such as depth phases. The beams are rectified by taking the envelope and then automatically aligned on the largest peak within 5 seconds of the expected arrival time. The station beams are then combined into network beams assuming a range of depths varying from 10 km to 700 km in increments of 1 km. The network beams are computed assuming both pP and sP propagation, and a measure of beam power is output as a function of depth for both propagation models, as well as their sum. We

  3. Highly effective portable beta spectrometer for precise depth selective electron Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Aldiyarov, N.U.; Kadyrzhanov, K.K.; Seytimbetov, A.M.; Zhdanov, V.S.

    2007-01-01

    Full text: More broad application of the nuclear-physical method of precise Depth Selective Electron Moessbauer Spectroscopy (DS EMS) is limited by insufficient accessibility of highly-effective beta spectrometers with acceptable resolution. It should be mentioned that the method DS EMS is realized at a combined installation that consists of a highly-effective beta spectrometer and a conventional portable nuclear gamma-resonance spectrometer. Yet few available beta spectrometers have sophisticated design and controlling; in most cases they are cumbersome. All the attempts to simplify beta spectrometers resulted in noticeable worsening of depth resolution for the DS EMS method making the measurements non precise. There is currently an obvious need in a highly-effective portable easily controlled beta spectrometer. While developing such portable beta spectrometer, it is more promising to use as basis a simpler spectrometer, which has ratio of sample size to spectrometer size of about five times. The paper presents an equal-arm version of a highly-effective portable beta spectrometer with transverse heterogeneous sector magnetic field that assures double focusing. The spectrometer is equipped with a large-area non-equipotential source (a sample under investigation) and a position-sensitive detector. This portable spectrometer meets all requirements for achievement of the DS EMS depth resolution close to the physical limit and demonstrates the following main characteristics: equilibrium orbit radius ρ 0 = 80 mm, instrumental energy resolution 0.6 % at solid angle 1 % of 4π steradian, area of non-equipotential source ∼ 80 mm 2 , registration by position-sensitive detector of ∼ 10 % of the energy interval. Highly-effective portable beta spectrometer assures obtaining Moessbauer data with depth resolution close to physical limit of the DS EMS method. So in measurements at conversion and Auger electrons with energies of about units of keV and above, the achieved

  4. Is visual short-term memory depthful?

    Science.gov (United States)

    Reeves, Adam; Lei, Quan

    2014-03-01

    Does visual short-term memory (VSTM) depend on depth, as it might be if information was stored in more than one depth layer? Depth is critical in natural viewing and might be expected to affect retention, but whether this is so is currently unknown. Cued partial reports of letter arrays (Sperling, 1960) were measured up to 700 ms after display termination. Adding stereoscopic depth hardly affected VSTM capacity or decay inferred from total errors. The pattern of transposition errors (letters reported from an uncued row) was almost independent of depth and cue delay. We conclude that VSTM is effectively two-dimensional. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Porosity and permeability evolution of vesicular basalt reservoirs with increasing depth: constraints from the Big Island of Hawai'i

    Science.gov (United States)

    Millett, John; Haskins, Eric; Thomas, Donald; Jerram, Dougal; Planke, Sverre; Healy, Dave; Kück, Jochem; Rossetti, Lucas; Farrell, Natalie; Pierdominici, Simona

    2017-04-01

    Volcanic reservoirs are becoming increasingly important in the targeting of petroleum, geothermal and water resources globally. However, key areas of uncertainty in relation to volcanic reservoir properties during burial in different settings remain. In this contribution, we present results from borehole logging and sampling operations within two fully cored c. 1.5 km deep boreholes, PTA2 and KMA1, from the Humúula saddle region on the Big Island of Hawai'i. The boreholes were drilled as part of the Humu'ula Groundwater Research Project (HGRP) between 2013-2016 and provide unique insights into the evolution of pore structure with increasing burial in a basaltic dominated lava sequence. The boreholes encounter mixed sequences of 'a'ā, pāhoehoe and transitional lava flows along with subsidiary intrusions and sediments from the shield to post-shield phases of Mauna Kea. Borehole wireline data including sonic, spectral gamma and Televiewer imagery were collected along with density, porosity, permeability and ultrasonic velocity laboratory measurements from core samples. A range of intra-facies were sampled for analysis from various depths within the two boreholes. By comparison with core data, the potential for high resolution Televiewer imaging to reveal spectacular intra-facies features including individual vesicles, vesicle segregations, 'a'ā rubble zones, intrusive contacts, and intricate pāhoehoe lava flow lobe morphologies is demonstrated. High quality core data enables the calibration of Televiewer facies enabling improved interpretation of volcanic reservoir features in the more common exploration scenario where core is absent. Laboratory results record the ability of natural vesicular basalt samples to host very high porosity (>50%) and permeability (>10 darcies) within lava flow top facies which we demonstrate are associated with vesicle coalescence and not micro-fractures. These properties may be maintained to depths of c. 1.5 km in regions of limited

  6. Determination of electron depth-dose curves for water, ICRU tissue, and PMMA and their application to radiation protection dosimetry

    International Nuclear Information System (INIS)

    Grosswendt, B.

    1994-01-01

    For monoenergetic electrons in the energy range between 60 keV and 10 MeV, normally incident on water, 4-element ICRU tissue and PMMA phantoms, depth-dose curves have been calculated using the Monte Carlo method. The phantoms' shape was that of a rectangular solid with a square front face of 30 cm x 30 cm and a thickness of 15 cm; it corresponds to that recommended by the ICRU for use in the procedure of calibrating radiation protection dosemeters. The depth-dose curves have been used to determine practical ranges, half-value depths, electron fluence to maximum absorbed dose conversion factors, and conversion factors between electron fluence and absorbed dose at depths d corresponding to 0.007 g.cm -2 , 0.3 g.cm -2 , and 1.0 g.cm -2 . The latter data can be used as fluence to dose equivalent conversion factors for extended parallel electron beams. (Author)

  7. The Influence of Sampling Density on Bayesian Age-Depth Models and Paleoclimatic Reconstructions - Lessons Learned from Lake Titicaca - Bolivia/Peru

    Science.gov (United States)

    Salenbien, W.; Baker, P. A.; Fritz, S. C.; Guedron, S.

    2014-12-01

    Lake Titicaca is one of the most important archives of paleoclimate in tropical South America, and prior studies have elucidated patterns of climate variation at varied temporal scales over the past 0.5 Ma. Yet, slow sediment accumulation rates in the main deeper basin of the lake have precluded analysis of the lake's most recent history at high resolution. To obtain a paleoclimate record of the last few millennia at multi-decadal resolution, we obtained five short cores, ranging from 139 to 181 cm in length, from the shallower Wiñaymarka sub-basin of of Lake Titicaca, where sedimentation rates are higher than in the lake's main basin. Selected cores have been analyzed for their geochemical signature by scanning XRF, diatom stratigraphy, sedimentology, and for 14C age dating. A total of 72 samples were 14C-dated using a Gas Ion Source automated high-throughput method for carbonate samples (mainly Littoridina sp. and Taphius montanus gastropod shells) at NOSAMS (Woods Hole Oceanographic Institute) with an analytical precision higher than 2%. The method has lower analytical precision compared with traditional AMS radiocarbon dating, but the lower cost enables analysis of a larger number of samples, and the error associated with the lower precision is relatively small for younger samples (< ~8,000 years). A 172-cm-long core was divided into centimeter long sections, and 47 14C dates were obtained from 1-cm intervals, averaging one date every 3-4 cm. The other cores were radiocarbon dated with a sparser sampling density that focused on visual unconformities and shell beds. The high-resolution radiocarbon analysis reveals complex sedimentation patterns in visually continuous sections, with abundant indicators of bioturbated or reworked sediments and periods of very rapid sediment accumulation. These features are not evident in the sparser sampling strategy but have significant implications for reconstructing past lake level and paleoclimatic history.

  8. KERNELHR: A program for estimating animal home ranges

    Science.gov (United States)

    Seaman, D.E.; Griffith, B.; Powell, R.A.

    1998-01-01

    Kernel methods are state of the art for estimating animal home-range area and utilization distribution (UD). The KERNELHR program was developed to provide researchers and managers a tool to implement this extremely flexible set of methods with many variants. KERNELHR runs interactively or from the command line on any personal computer (PC) running DOS. KERNELHR provides output of fixed and adaptive kernel home-range estimates, as well as density values in a format suitable for in-depth statistical and spatial analyses. An additional package of programs creates contour files for plotting in geographic information systems (GIS) and estimates core areas of ranges.

  9. Hydrologic regulation of plant rooting depth.

    Science.gov (United States)

    Fan, Ying; Miguez-Macho, Gonzalo; Jobbágy, Esteban G; Jackson, Robert B; Otero-Casal, Carlos

    2017-10-03

    Plant rooting depth affects ecosystem resilience to environmental stress such as drought. Deep roots connect deep soil/groundwater to the atmosphere, thus influencing the hydrologic cycle and climate. Deep roots enhance bedrock weathering, thus regulating the long-term carbon cycle. However, we know little about how deep roots go and why. Here, we present a global synthesis of 2,200 root observations of >1,000 species along biotic (life form, genus) and abiotic (precipitation, soil, drainage) gradients. Results reveal strong sensitivities of rooting depth to local soil water profiles determined by precipitation infiltration depth from the top (reflecting climate and soil), and groundwater table depth from below (reflecting topography-driven land drainage). In well-drained uplands, rooting depth follows infiltration depth; in waterlogged lowlands, roots stay shallow, avoiding oxygen stress below the water table; in between, high productivity and drought can send roots many meters down to the groundwater capillary fringe. This framework explains the contrasting rooting depths observed under the same climate for the same species but at distinct topographic positions. We assess the global significance of these hydrologic mechanisms by estimating root water-uptake depths using an inverse model, based on observed productivity and atmosphere, at 30″ (∼1-km) global grids to capture the topography critical to soil hydrology. The resulting patterns of plant rooting depth bear a strong topographic and hydrologic signature at landscape to global scales. They underscore a fundamental plant-water feedback pathway that may be critical to understanding plant-mediated global change.

  10. Hydrologic regulation of plant rooting depth

    Science.gov (United States)

    Fan, Ying; Miguez-Macho, Gonzalo; Jobbágy, Esteban G.; Jackson, Robert B.; Otero-Casal, Carlos

    2017-10-01

    Plant rooting depth affects ecosystem resilience to environmental stress such as drought. Deep roots connect deep soil/groundwater to the atmosphere, thus influencing the hydrologic cycle and climate. Deep roots enhance bedrock weathering, thus regulating the long-term carbon cycle. However, we know little about how deep roots go and why. Here, we present a global synthesis of 2,200 root observations of >1,000 species along biotic (life form, genus) and abiotic (precipitation, soil, drainage) gradients. Results reveal strong sensitivities of rooting depth to local soil water profiles determined by precipitation infiltration depth from the top (reflecting climate and soil), and groundwater table depth from below (reflecting topography-driven land drainage). In well-drained uplands, rooting depth follows infiltration depth; in waterlogged lowlands, roots stay shallow, avoiding oxygen stress below the water table; in between, high productivity and drought can send roots many meters down to the groundwater capillary fringe. This framework explains the contrasting rooting depths observed under the same climate for the same species but at distinct topographic positions. We assess the global significance of these hydrologic mechanisms by estimating root water-uptake depths using an inverse model, based on observed productivity and atmosphere, at 30″ (˜1-km) global grids to capture the topography critical to soil hydrology. The resulting patterns of plant rooting depth bear a strong topographic and hydrologic signature at landscape to global scales. They underscore a fundamental plant-water feedback pathway that may be critical to understanding plant-mediated global change.

  11. Cosmogenic 10Be Depth Profile in top 560 m of West Antarctic Ice Sheet Divide Ice Core

    Science.gov (United States)

    Welten, K. C.; Woodruff, T. E.; Caffee, M. W.; Edwards, R.; McConnell, J. R.; Bisiaux, M. M.; Nishiizumi, K.

    2009-12-01

    Concentrations of cosmogenic 10Be in polar ice samples are a function of variations in solar activity, geomagnetic field strength, atmospheric mixing and annual snow accumulation rates. The 10Be depth profile in ice cores also provides independent chronological markers to tie Antarctic to Greenland ice cores and to tie Holocene ice cores to the 14C dendrochronology record. We measured 10Be concentrations in 187 samples from depths of 0-560 m of the main WAIS Divide core, WDC06A. The ice samples are typically 1-2 kg and represent 2-4 m of ice, equivalent to an average temporal resolution of ~12 years, based on the preliminary age-depth scale proposed for the WDC core, (McConnell et al., in prep). Be, Al and Cl were separated using ion exchange chromatography techniques and the 10Be concentrations were measured by accelerator mass spectrometry (AMS) at PRIME lab. The 10Be concentrations range from 8.1 to 19.1 x 10^3 at/g, yielding an average of (13.1±2.1) x 10^3 at/g. Adopting an average snow accumulation rate of 20.9 cm weq/yr, as derived from the age-depth scale, this value corresponds to an average 10Be flux of (2.7±0.5) x 10^5 atoms/yr/cm2. This flux is similar to that of the Holocene part of the Siple Dome (Nishiizumi and Finkel, 2007) and Dome Fuji (Horiuchi et al. 2008) ice cores, but ~30% lower than the value of 4.0 x 10^5 atoms/yr/cm2 for GISP2 (Finkel and Nishiizumi, 1997). The periods of low solar activity, known as Oort, Wolf, Spörer, Maunder and Dalton minima, show ~20% higher 10Be concentrations/fluxes than the periods of average solar activity in the last millennium. The maximum 10Be fluxes during some of these periods of low solar activity are up to ~50% higher than average 10Be fluxes, as seen in other polar ice cores, which makes these peaks suitable as chronologic markers. We will compare the 10Be record in the WAIS Divide ice core with that in other Antarctic as well as Greenland ice cores and with the 14C treering record. Acknowledgment. This

  12. REPEATABILITY AND ACCURACY OF EXOPLANET ECLIPSE DEPTHS MEASURED WITH POST-CRYOGENIC SPITZER

    Energy Technology Data Exchange (ETDEWEB)

    Ingalls, James G.; Krick, J. E.; Carey, S. J.; Stauffer, John R.; Lowrance, Patrick J.; Grillmair, Carl J.; Capak, Peter; Glaccum, William; Laine, Seppo; Surace, Jason; Storrie-Lombardi, Lisa [Spitzer Science Center, California Institute of Technology, 1200 E California Boulevard, Mail Code 314-6, Pasadena, CA 91125 (United States); Buzasi, Derek [Department of Chemistry and Physics, Florida Gulf Coast University, Fort Myers, FL 33965 (United States); Deming, Drake [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Diamond-Lowe, Hannah; Stevenson, Kevin B. [Department of Astronomy and Astrophysics, University of Chicago, 5640 S Ellis Avenue, Chicago, IL 60637 (United States); Evans, Thomas M. [School of Physics, University of Exeter, EX4 4QL Exeter (United Kingdom); Morello, G. [Department of Physics and Astronomy, University College London, Gower Street, WC1 E6BT (United Kingdom); Wong, Ian, E-mail: ingalls@ipac.caltech.edu [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States)

    2016-08-01

    We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5 μ m data set, consisting of 10 observations of the XO-3b system during secondary eclipse, using seven different techniques for removing correlated noise. We find that, on average, for a given technique, the eclipse depth estimate is repeatable from epoch to epoch to within 156 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 3 of the photon noise limit. All methods but one accurately assess their own errors: for these methods, the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10 epoch sample. To assess the accuracy of the techniques as well as to clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated data set of 10 visits to XO-3b, for which the eclipse depth is known. We find that three of the methods (BLISS mapping, Pixel Level Decorrelation, and Independent Component Analysis) obtain results that are within three times the photon limit of the true eclipse depth. When averaged over the 10 epoch ensemble,  5 out of 7 techniques come within 60 ppm of the true value. Spitzer exoplanet data, if obtained following current best practices and reduced using methods such as those described here, can measure repeatable and accurate single eclipse depths, with close to photon-limited results.

  13. Nanometric resolution in glow discharge optical emission spectroscopy and Rutherford backscattering spectrometry depth profiling of metal (Cr, Al) nitride multilayers

    International Nuclear Information System (INIS)

    Escobar Galindo, R.; Gago, R.; Fornies, E.; Munoz-Martin, A.; Climent Font, A.; Albella, J.M.

    2006-01-01

    In this work, we address the capability of glow discharge optical emission spectroscopy (GDOES) for fast and accurate depth profiling of multilayer nitride coatings down to the nanometer range. This is shown by resolving the particular case of CrN/AlN structures with individual thickness ranging from hundreds to few nanometers. In order to discriminate and identify artefacts in the GDOES depth profile due to the sputtering process, the layered structures were verified by Rutherford backscattering spectrometry (RBS) and scanning electron microscopy (SEM). The interfaces in the GDOES profiles for CrN/AlN structures are sharper than the ones measured for similar metal multilayers due to the lower sputtering rate of the nitrides. However, as a consequence of the crater shape, there is a linear degradation of the depth resolution with depth (approximately 40 nm/μm), saturating at a value of approximately half the thickness of the thinner layer. This limit is imposed by the simultaneous sputtering of consecutive layers. The ultimate GDOES depth resolution at the near surface region was estimated to be of 4-6 nm

  14. Oxygen depth profiling in Kr{sup +}-implanted polycrystalline alpha titanium by means of {sup 16}O({alpha},{alpha}){sup 16}O resonance scattering

    Energy Technology Data Exchange (ETDEWEB)

    Nsengiyumva, S., E-mail: schadnse@hotmail.com [Department of Physics, University of Cape Town, Rondebosch 7701 (South Africa); Department of Physics and Electronics, Rhodes University, Grahamstown 6140 (South Africa); Department of Physics, Kigali Institute of Education, P.O. Box 5039 Kigali (Rwanda); Riviere, J.P. [Laboratoire de Physique des Materiaux UMR6630-CNRS, 86960 (France); Raji, A.T.; Comrie, C.M.; Britton, D.T.; Haerting, M. [Department of Physics, University of Cape Town, Rondebosch 7701 (South Africa)

    2011-07-15

    The {sup 16}O({alpha},{alpha}){sup 16}O resonance scattering was applied to study the effects of ion implantation on the oxygen distribution in the near surface region of polycrystalline titanium implanted with 180 keV krypton ions at fluences, ranging between 1 x 10{sup 14} and 5 x 10{sup 15} Kr{sup +}/cm{sup 2}. Two sample sets were chosen: as-received polycrystalline titanium discs rolled and annealed in half-hard condition which had a thick oxygen layer and similar samples in which this surface layer was removed by polishing. An increase of the mean oxygen concentration observed in both unpolished and polished samples at low fluence suggests a knock-on implantation of surface oxygen atoms. At high fluence, an overall decrease in the mean oxygen concentration and mean oxygen depth suggests an out-diffusion of near-surface oxygen atoms.

  15. In situ photobiology of corals over large depth ranges: A multivariate analysis on the roles of environment, host, and algal symbiont

    NARCIS (Netherlands)

    Frade, P.R.; Bongaerts, P.; Winkelhagen, A.J.S.; Tonk, L.; Bak, R.P.M.

    2008-01-01

    We applied a multivariate analysis to investigate the roles of host and symbiont on the in situ physiological response of genus Madracis holobionts towards light. Across a large depth gradient (5-40 m) and for four Madracis species and three symbiont genotypes, we assessed several variables by

  16. Anthropometry and Range of Motion of the Encumbered Soldier

    Science.gov (United States)

    2017-03-01

    claims of the encumbered dismounted Soldier. Soldiers are required to wear multiple layers of clothing and protective equipment in addition to mission...depth (i.e., bulk) measurements related to Soldier CIE that had a significant decrement on the Soldiers’ range of motion for many body movements...bulk) measurements related to Soldier CIE that had a significant decrement on the Soldiers’ range of motion for many body movements. The

  17. Comparison of EGS4 and MCNP Monte Carlo codes when calculating radiotherapy depth doses.

    Science.gov (United States)

    Love, P A; Lewis, D G; Al-Affan, I A; Smith, C W

    1998-05-01

    The Monte Carlo codes EGS4 and MCNP have been compared when calculating radiotherapy depth doses in water. The aims of the work were to study (i) the differences between calculated depth doses in water for a range of monoenergetic photon energies and (ii) the relative efficiency of the two codes for different electron transport energy cut-offs. The depth doses from the two codes agree with each other within the statistical uncertainties of the calculations (1-2%). The relative depth doses also agree with data tabulated in the British Journal of Radiology Supplement 25. A discrepancy in the dose build-up region may by attributed to the different electron transport algorithims used by EGS4 and MCNP. This discrepancy is considerably reduced when the improved electron transport routines are used in the latest (4B) version of MCNP. Timing calculations show that EGS4 is at least 50% faster than MCNP for the geometries used in the simulations.

  18. Effect of insertion depth on helical antenna performance in a muscle-equivalent phantom

    Energy Technology Data Exchange (ETDEWEB)

    Reeves, J W; Meeson, S; Birch, M J [Department of Clinical Physics, Royal London Hospital, 56-76 Ashfield Street, London, E1 1BB (United Kingdom)

    2005-06-21

    Barrett's oesophagus is considered to increase the risk of cancer 30 fold. A set of helical microwave antennas was designed to investigate their potential use in the thermal therapy of Barrett's oesophagus. For treatment, a balloon filled with muscle-equivalent material encapsulates the antenna. The effects of insertion depth and coil-spacing on the thermal distribution produced by the antennas (20-35 mm) were characterized. The 35 mm helical antenna, with a coil-spacing of 3.6 mm resulted in uniform heating for an insertion depth of 40 mm. It was observed that the resultant temperature distribution produced, by the antennas, was dependent on the insertion depth within the phantom. For all antennas studied, deeper insertion resulted in two high intensity regions, approximately 1/4 and 3/4 along the antenna length. In contrast, shallow insertion resulted in predominant tip heating with undesirable heating at the phantom entry point. However, by manipulating the coil-spacing of the helix, uniform temperature profiles were achieved for a range of insertion depths.

  19. Digging a Little Deeper: Microbial Communities, Molecular Composition and Soil Organic Matter Turnover along Tropical Forest Soil Depth Profiles

    Science.gov (United States)

    Pett-Ridge, J.; McFarlane, K. J.; Heckman, K. A.; Reed, S.; Green, E. A.; Nico, P. S.; Tfaily, M. M.; Wood, T. E.; Plante, A. F.

    2016-12-01

    Tropical forest soils store more carbon (C) than any other terrestrial ecosystem and exchange vast amounts of CO2, water, and energy with the atmosphere. Much of this C is leached and stored in deep soil layers where we know little about its fate or the microbial communities that drive deep soil biogeochemistry. Organic matter (OM) in tropical soils appears to be associated with mineral particles, suggesting deep soils may provide greater C stabilization. However, few studies have evaluated sub-surface soils in tropical ecosystems, including estimates of the turnover times of deep soil C, the sensitivity of this C to global environmental change, and the microorganisms involved. We quantified bulk C pools, microbial communities, molecular composition of soil organic matter, and soil radiocarbon turnover times from surface soils to 1.5m depths in multiple soil pits across the Luquillo Experimental Forest, Puerto Rico. Soil C, nitrogen, and root and microbial biomass all declined exponentially with depth; total C concentrations dropped from 5.5% at the surface to communities in surface soils (Acidobacteria and Proteobacteria) versus those below the active rooting zone (Verrucomicrobia and Thaumarchaea). High resolution mass spectrometry (FTICR-MS) analyses suggest a shift in the composition of OM with depth (especially in the water soluble fraction), an increase in oxidation, and decreasing H/C with depth (indicating higher aromaticity). Additionally, surface samples were rich in lignin-like compounds of plant origin that were absent with depth. Soil OM 14C and mean turnover times were variable across replicate horizons, ranging from 3-1500 years at the surface, to 5000-40,000 years at depth. In comparison to temperate deciduous forests, these 14C values reflect far older soil C. Particulate organic matter (free light fraction), with a relatively modern 14C was found in low but measureable concentration in even the deepest soil horizons. Our results indicate these

  20. High dynamic range coding imaging system

    Science.gov (United States)

    Wu, Renfan; Huang, Yifan; Hou, Guangqi

    2014-10-01

    We present a high dynamic range (HDR) imaging system design scheme based on coded aperture technique. This scheme can help us obtain HDR images which have extended depth of field. We adopt Sparse coding algorithm to design coded patterns. Then we utilize the sensor unit to acquire coded images under different exposure settings. With the guide of the multiple exposure parameters, a series of low dynamic range (LDR) coded images are reconstructed. We use some existing algorithms to fuse and display a HDR image by those LDR images. We build an optical simulation model and get some simulation images to verify the novel system.

  1. Representative process sampling for reliable data analysis

    DEFF Research Database (Denmark)

    Julius, Lars Petersen; Esbensen, Kim

    2005-01-01

    (sampling variances) can be reduced greatly however, and sampling biases can be eliminated completely, by respecting a simple set of rules and guidelines provided by TOS. A systematic approach for description of process heterogeneity furnishes in-depth knowledge about the specific variability of any 1-D lot...

  2. Assessment of Sampling Error Associated with Collection and Analysis of Soil Samples at a Firing Range Contaminated with HMX

    National Research Council Canada - National Science Library

    Jenkins, Thomas F

    1997-01-01

    Short-range and mid-range (grid size) spatial heterogeneity in explosives concentrations within surface soils was studied at an active antitank firing range at the Canadian Force Base-Valcartier, Val-Belair, Quebec...

  3. Effects of burn location and investigator on burn depth in a porcine model.

    Science.gov (United States)

    Singer, Adam J; Toussaint, Jimmy; Chung, Won Taek; Thode, Henry C; McClain, Steve; Raut, Vivek

    2016-02-01

    In order to be useful, animal models should be reproducible and consistent regardless of sampling bias, investigator creating burn, and burn location. We determined the variability in burn depth based on biopsy location, burn location and investigator in a porcine model of partial thickness burns. 24 partial thickness burns (2.5 cm by 2.5 cm each) were created on the backs of 2 anesthetized pigs by 2 investigators (one experienced, one inexperienced) using a previously validated model. In one of the pigs, the necrotic epidermis covering each burn was removed. Five full thickness 4mm punch biopsies were obtained 1h after injury from the four corners and center of the burns and stained with Hematoxylin and Eosin and Masson's trichrome for determination of burn depth by a board certified dermatopathologist blinded to burn location and investigator. Comparisons of burn depth by biopsy location, burn location and investigator were performed with t-tests and ANOVA as appropriate. The mean (SD) depth of injury to blood vessels (the main determinant of burn progression) in debrided and non-debrided pigs pooled together was 1.8 (0.3)mm, which included 75% of the dermal depth. Non-debrided burns were 0.24 mm deeper than debrided burns (Plocations, in debrided burns. Additionally, there were also no statistical differences in burn depths from midline to lateral in either of these burn types. Burn depth was similar for both investigators and among biopsy locations. Burn depth was greater for caudal locations in non-debrided burns and overall non-debrided burns were deeper than debrided burns. However, burn depth did not differ based on investigator, biopsy site, and medial-lateral location. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  4. Depth of Cervical Intraepithelial Neoplasia Grade 3 in Peruvian Women: Implications for Therapeutic Depth of Necrosis.

    Science.gov (United States)

    Taxa, Luis; Jeronimo, Jose; Alonzo, Todd A; Gage, Julia; Castle, Philip E; Cremer, Miriam L; Felix, Juan C

    2018-01-01

    To determine the involvement of cervical intraepithelial neoplasia grade 3 (CIN3) in a population of women in a lower-resource setting. One hundred twelve consecutive cone excision specimens with histological diagnosis of CIN3 were retrieved from the National Institute of Neoplastic Diseases in Lima Peru. Two pathologists independently evaluated each specimen microscopically and confirmed 107 cases that could be measured by optical micrometry. Depth and breadth of the lesions were measured microscopically. The mean maximal depth of cervical involvement by CIN3 was 2 ± 0.13 mm; depth was less than 3.5 mm in 89.7% of cases and less than 5 mm in 93.5%. Mean breadth of CIN3 was 7.3 ± 4.4 mm; breadth was less than 15.9 mm in 95% of cases and less than 20.5 mm in 99.7%. The correlation coefficient between breadth and depth of CIN3 was 0.61. No significant correlation was found between age and depth. Depth of CIN3 involvement in a developing country is significantly deeper than that reported in the United States. Treatment selection for women with CIN3 and risk of treatment failure may vary between developing and developed countries because of the difference in the depth of lesions. Countries with underscreened populations need to consider the increased disease severity in devising treatment strategies.

  5. Measurements of nitrogen depth distribution in the surface of steel with the 14N(d,p0)15N reaction

    International Nuclear Information System (INIS)

    Didriksson, R.; Goenczi, L.; Sundqvist, B.

    1980-01-01

    The 14 N(d,p 0 ) 15 N nuclear reaction has been used to measure the nitrogen depth distribution in the surface of steel samples. With a beam energy of 2.5 MeV a depth of 15μm could be analyzed. The depth resolution was 0.7 μm (FWHM) and nitrogen contents down to 0.02 percent could be determined. (author)

  6. Emission Depth Distribution Function of Al 2s Photoelectrons in Al2O3

    Science.gov (United States)

    Hucek, S.; Zemek, J.; Jablonski, A.; Tilinin, I. S.

    The escape probability of Al 2s photoelectrons leaving an aluminum oxide sample (Al2O3) has been studied as a function of depth of origin. It has been found that the escape probability (the so-called emission depth distribution function - DDF) depends strongly on the photoelectron emission direction with respect to that of the incident X-ray beam. In particular, in the emission direction close to that of photon propagation, the DDF differs substantially from the simple Beer-Lambert law and exhibits a nonmonotonic behavior with a maximum in the near-surface region at a depth of about 10 Å. Experimental results are in good agreement with theoretical predictions based on Monte Carlo simulations of the electron transport and with analytical solution of the linearized Boltzmann kinetic equation with appropriate boundary conditions. Both theoretical approaches take into account multiple elastic scattering of photoelectrons on their way out of the sample. It is shown that the commonly used straight line approximation (SLA), which neglects elastic scattering effects, fails to describe adequately experimental data at emission directions close to minima of the differential photoelectric cross section.

  7. Z-depth integration: a new technique for manipulating z-depth properties in composited scenes

    Science.gov (United States)

    Steckel, Kayla; Whittinghill, David

    2014-02-01

    This paper presents a new technique in the production pipeline of asset creation for virtual environments called Z-Depth Integration (ZeDI). ZeDI is intended to reduce the time required to place elements at the appropriate z-depth within a scene. Though ZeDI is intended for use primarily in two-dimensional scene composition, depth-dependent "flat" animated objects are often critical elements of augmented and virtual reality applications (AR/VR). ZeDI is derived from "deep image compositing", a capacity implemented within the OpenEXR file format. In order to trick the human eye into perceiving overlapping scene elements as being in front of or behind one another, the developer must manually manipulate which pixels of an element are visible in relation to other objects embedded within the environment's image sequence. ZeDI improves on this process by providing a means for interacting with procedurally extracted z-depth data from a virtual environment scene. By streamlining the process of defining objects' depth characteristics, it is expected that the time and energy required for developers to create compelling AR/VR scenes will be reduced. In the proof of concept presented in this manuscript, ZeDI is implemented for pre-rendered virtual scene construction via an AfterEffects software plug-in.

  8. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  9. DS86 neutron dose. Monte Carlo analysis for depth profile of {sup 152}Eu activity in a large stone sample

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Satoru; Hoshi, Masaharu; Takada, Jun [Hiroshima Univ. (Japan). Research Inst. for Radiation Biology and Medicine; Iwatani, Kazuo; Oka, Takamitsu; Shizuma, Kiyoshi; Imanaka, Tetsuji; Fujita, Shoichiro; Hasai, Hiromi

    1999-06-01

    The depth profile of {sup 152}Eu activity induced in a large granite stone pillar by Hiroshima atomic bomb neutrons was calculated by a Monte Carlo N-Particle Transport Code (MCNP). The pillar was on the Motoyasu Bridge, located at a distance of 132 m (WSW) from the hypocenter. It was a square column with a horizontal sectional size of 82.5 cm x 82.5 cm and height of 179 cm. Twenty-one cells from the north to south surface at the central height of the column were specified for the calculation and {sup 152}Eu activities for each cell were calculated. The incident neutron spectrum was assumed to be the angular fluence data of the Dosimetry System 1986 (DS86). The angular dependence of the spectrum was taken into account by dividing the whole solid angle into twenty-six directions. The calculated depth profile of specific activity did not agree with the measured profile. A discrepancy was found in the absolute values at each depth with a mean multiplication factor of 0.58 and also in the shape of the relative profile. The results indicated that a reassessment of the neutron energy spectrum in DS86 is required for correct dose estimation. (author)

  10. Offshore Wind Technology Depth Zones

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Coastal bathymetric depth, measured in meters at depth values of: -30, -60, -900 Shallow Zone (0-30m): Technology has been demonstrated on a commercial scale at...

  11. Multicriteria Similarity-Based Anomaly Detection Using Pareto Depth Analysis.

    Science.gov (United States)

    Hsiao, Ko-Jen; Xu, Kevin S; Calder, Jeff; Hero, Alfred O

    2016-06-01

    We consider the problem of identifying patterns in a data set that exhibits anomalous behavior, often referred to as anomaly detection. Similarity-based anomaly detection algorithms detect abnormally large amounts of similarity or dissimilarity, e.g., as measured by the nearest neighbor Euclidean distances between a test sample and the training samples. In many application domains, there may not exist a single dissimilarity measure that captures all possible anomalous patterns. In such cases, multiple dissimilarity measures can be defined, including nonmetric measures, and one can test for anomalies by scalarizing using a nonnegative linear combination of them. If the relative importance of the different dissimilarity measures are not known in advance, as in many anomaly detection applications, the anomaly detection algorithm may need to be executed multiple times with different choices of weights in the linear combination. In this paper, we propose a method for similarity-based anomaly detection using a novel multicriteria dissimilarity measure, the Pareto depth. The proposed Pareto depth analysis (PDA) anomaly detection algorithm uses the concept of Pareto optimality to detect anomalies under multiple criteria without having to run an algorithm multiple times with different choices of weights. The proposed PDA approach is provably better than using linear combinations of the criteria, and shows superior performance on experiments with synthetic and real data sets.

  12. Effects of magnification and zooming on depth perception in digital stereomammography: an observer performance study

    International Nuclear Information System (INIS)

    Chan Heangping; Goodsitt, Mitchell M; Hadjiiski, Lubomir M; Bailey, Janet E; Klein, Katherine; Darner, Katie L; Sahiner, Berkman

    2003-01-01

    We are evaluating the application of stereoscopic imaging to digital mammography. In the current study, we investigated the effects of magnification and zooming on depth perception. A modular phantom was designed which contained six layers of 1-mm-thick Lexan plates, each spaced 1 mm apart. Eight to nine small, thin nylon fibrils were pasted on each plate in horizontal or vertical orientations such that they formed 25 crossing fibril pairs in a projected image. The depth separation between each fibril pair ranged from 2 to 10 mm. A change in the order of the Lexan plates changed the depth separation of the two fibrils in a pair. Stereoscopic image pairs of the phantom were acquired with a GE full-field digital mammography system. Three different phantom configurations were imaged. All images were obtained using a Rh target/Rh filter spectrum at 30 kVp tube potential and a ±3 degrees stereo shift angle. Images were acquired in both contact and 1.8X magnification geometry and an exposure range of 4 to 63 mAs was employed. The images were displayed on a Barco monitor driven by a Metheus stereo graphics board and viewed with LCD stereo glasses. Five observers participated in the study. Each observer visually judged whether the vertical fibril was in front of or behind the horizontal fibril in each fibril pair. It was found that the accuracy of depth discrimination increased with increasing fibril depth separation and x-ray exposure. The accuracy was not improved by electronic display zooming of the contact stereo images by 2X. Under conditions of high noise (low mAs) and small depth separation between the fibrils, the observers' depth discrimination ability was significantly better in stereo images acquired with geometric magnification than in images acquired with a contact technique and displayed with or without zooming. Under our experimental conditions, a 2 mm depth discrimination was achieved with over 60% accuracy on contact images with and without zooming, and

  13. Depth of magnetic basement in Iran based on fractal spectral analysis of aeromagnetic data

    Science.gov (United States)

    Teknik, Vahid; Ghods, Abdolreza

    2017-06-01

    To estimate the shape of sedimentary basins, a critical parameter in hydrocarbon exploration, we calculated the depth of magnetic basement by applying a fractal spectral method to the aeromagnetic map of Iran. The depth of magnetic basement is a close proxy for the shape of sedimentary basins provided that igneous basement is strongly magnetized relative to the overlying sediments and there is no interbedding magnetic layer in the sediments. The shape of the power spectrum of magnetic anomalies is sensitive to the depth of magnetic basement, the thickness of the magnetic layer, the fractal parameter of magnetization and the size of the window used for the calculation of the power spectrum. Using a suite of synthetic tests, we have shown that the estimation of the depth of magnetic basement of up to 20 km is not very sensitive to the often unknown fractal parameter and thus the spectral method is a reliable tool to calculate the depth of magnetic basement. The depth of magnetic basement is in the range of 7-16 km in the Zagros, east Alborz, Tabas, Jazmurian and Makran regions, showing a close correlation with depths estimated from the maximum thickness of stratigraphic columns. We have also found new sedimentary basins in Bostan Abad, Bijar and south of Orumiyeh Lake. The significant depth of the magnetic basement in the Makran, Jazmurain depression, southeast Caspian Sea, Tabas, Great Kavir, south of Orumiyeh Lake, Bostan Abad and Bijar sedimentary basins makes them future prospects for hydrocarbon explorations. The depth of magnetic basement is strongly reduced over the Neyriz and Kermanshah Ophiolites, but it does not show any meaningful correlation with other outcrops of ophiolitic rocks in Iran.

  14. Accurate depth profiling for ultra-shallow implants using backside-SIMS

    International Nuclear Information System (INIS)

    Hongo, Chie; Tomita, Mitsuhiro; Takenaka, Miyuki

    2004-01-01

    We studied methods for accurate depth profiling for ultra-shallow implants using backside-SIMS. For the measurement of ultra-shallow profiles, the effects of surface transient and atomic mixing are not negligible. Therefore, we applied backside-SIMS to analyze ultra-shallow doping in order to exclude these effects. Backside-SIMS profiles show a sharper ion implantation tail than surface-side-SIMS profiles. In addition, the primary ion energy dependence becomes weaker when backside-SIMS is used [Surf. Interf. Anal. 29 (2000) 362; Appl. Surf. Sci. 203-204 (2003) 264; J. Vac. Sci. Technol. B 21 (2003) 1422]. However, the peak concentration of the backside sample was lower than that of the surface-side sample. Therefore, the sample flatness was estimated using the SIMS response function. Furthermore, SIMS profiles were simulated using SIMS response functions. This simulation shows how the sample flatness affects the SIMS profile

  15. The influence of angle of insonation and target depth on speckle-tracking strain

    DEFF Research Database (Denmark)

    Forsha, Daniel; Risum, Niels; Rajagopal, Sudarshan

    2015-01-01

    was to assess the influence of angle and depth on longitudinal peak systolic strain (LPS). METHODS: Thirty-four healthy pediatric subjects (age range, 6-18 years; 47% male) with normal cardiac anatomy and good image quality were prospectively imaged. Angular comparisons of LPS were investigated by examining...

  16. Hydrologic controls on equilibrium soil depths

    Science.gov (United States)

    Nicótina, L.; Tarboton, D. G.; Tesfa, T. K.; Rinaldo, A.

    2011-04-01

    This paper deals with modeling the mutual feedbacks between runoff production and geomorphological processes and attributes that lead to patterns of equilibrium soil depth. Our primary goal is an attempt to describe spatial patterns of soil depth resulting from long-term interactions between hydrologic forcings and soil production, erosion, and sediment transport processes under the framework of landscape dynamic equilibrium. Another goal is to set the premises for exploiting the role of soil depths in shaping the hydrologic response of a catchment. The relevance of the study stems from the massive improvement in hydrologic predictions for ungauged basins that would be achieved by using directly soil depths derived from geomorphic features remotely measured and objectively manipulated. Hydrological processes are here described by explicitly accounting for local soil depths and detailed catchment topography. Geomorphological processes are described by means of well-studied geomorphic transport laws. The modeling approach is applied to the semiarid Dry Creek Experimental Watershed, located near Boise, Idaho. Modeled soil depths are compared with field data obtained from an extensive survey of the catchment. Our results show the ability of the model to describe properly the mean soil depth and the broad features of the distribution of measured data. However, local comparisons show significant scatter whose origins are discussed.

  17. Depth estimation of complex geometry scenes from light fields

    Science.gov (United States)

    Si, Lipeng; Wang, Qing

    2018-01-01

    The surface camera (SCam) of light fields gathers angular sample rays passing through a 3D point. The consistency of SCams is evaluated to estimate the depth map of scene. But the consistency is affected by several limitations such as occlusions or non-Lambertian surfaces. To solve those limitations, the SCam is partitioned into two segments that one of them could satisfy the consistency constraint. The segmentation pattern of SCam is highly related to the texture of spatial patch, so we enforce a mask matching to describe the shape correlation between segments of SCam and spatial patch. To further address the ambiguity in textureless region, a global method with pixel-wise plane label is presented. Plane label inference at each pixel can recover not only depth value but also local geometry structure, that is suitable for light fields with sub-pixel disparities and continuous view variation. Our method is evaluated on public light field datasets and outperforms the state-of-the-art.

  18. Spatial resolution in depth-controlled surface sensitive x-ray techniques

    International Nuclear Information System (INIS)

    Yun, W.B.; Viccaro, P.J.

    1992-01-01

    The spatial resolution along the surface normal and the total depth probed are two important parameters in depth-controlled surface sensitive X-ray techniques employing grazing incidence geometry. The two parameters are analyzed in terms of optical properties (refractive indices) of the media involved and parameters of the incident X-ray beam: beam divergence, X-ray energy, and spectral bandwidth. We derive analytical expressions of the required beam divergence and spectral bandwidth of the incident beam as a function of the two parameters. Sample calculations are made for X-ray energies between 0.1 and 100 keV and for solid Be, Cu, and Au, representing material matrices consisting of low, medium, and high atomic number elements. A brief discussion on obtaining the required beam divergence and spectral bandwidth from present X-ray sources and optics is given

  19. Assessment of Zooplankton Community Composition along a Depth Profile in the Central Red Sea

    KAUST Repository

    Pearman, John K.; Irigoien, Xabier

    2015-01-01

    community. The genus Corycaeus had a higher proportion of reads in the epipelagic zone with Pleuromamma becoming increasingly dominant with depth. No significant difference was observed in the community between night and day sampling however there was a

  20. An efficient parallel algorithm: Poststack and prestack Kirchhoff 3D depth migration using flexi-depth iterations

    Science.gov (United States)

    Rastogi, Richa; Srivastava, Abhishek; Khonde, Kiran; Sirasala, Kirannmayi M.; Londhe, Ashutosh; Chavhan, Hitesh

    2015-07-01

    This paper presents an efficient parallel 3D Kirchhoff depth migration algorithm suitable for current class of multicore architecture. The fundamental Kirchhoff depth migration algorithm exhibits inherent parallelism however, when it comes to 3D data migration, as the data size increases the resource requirement of the algorithm also increases. This challenges its practical implementation even on current generation high performance computing systems. Therefore a smart parallelization approach is essential to handle 3D data for migration. The most compute intensive part of Kirchhoff depth migration algorithm is the calculation of traveltime tables due to its resource requirements such as memory/storage and I/O. In the current research work, we target this area and develop a competent parallel algorithm for post and prestack 3D Kirchhoff depth migration, using hybrid MPI+OpenMP programming techniques. We introduce a concept of flexi-depth iterations while depth migrating data in parallel imaging space, using optimized traveltime table computations. This concept provides flexibility to the algorithm by migrating data in a number of depth iterations, which depends upon the available node memory and the size of data to be migrated during runtime. Furthermore, it minimizes the requirements of storage, I/O and inter-node communication, thus making it advantageous over the conventional parallelization approaches. The developed parallel algorithm is demonstrated and analysed on Yuva II, a PARAM series of supercomputers. Optimization, performance and scalability experiment results along with the migration outcome show the effectiveness of the parallel algorithm.

  1. Procedures for sampling radium-contaminated soils

    International Nuclear Information System (INIS)

    Fleischhauer, H.L.

    1985-10-01

    Two procedures for sampling the surface layer (0 to 15 centimeters) of radium-contaminated soil are recommended for use in remedial action projects. Both procedures adhere to the philosophy that soil samples should have constant geometry and constant volume in order to ensure uniformity. In the first procedure, a ''cookie cutter'' fashioned from pipe or steel plate, is driven to the desired depth by means of a slide hammer, and the sample extracted as a core or plug. The second procedure requires use of a template to outline the sampling area, from which the sample is obtained using a trowel or spoon. Sampling to the desired depth must then be performed incrementally. Selection of one procedure over the other is governed primarily by soil conditions, the cookie cutter being effective in nongravelly soils, and the template procedure appropriate for use in both gravelly and nongravelly soils. In any event, a minimum sample volume of 1000 cubic centimeters is recommended. The step-by-step procedures are accompanied by a description of the minimum requirements for sample documentation. Transport of the soil samples from the field is then addressed in a discussion of the federal regulations for shipping radioactive materials. Interpretation of those regulations, particularly in light of their application to remedial action soil-sampling programs, is provided in the form of guidance and suggested procedures. Due to the complex nature of the regulations, however, there is no guarantee that our interpretations of them are complete or entirely accurate. Preparation of soil samples for radium-226 analysis by means of gamma-ray spectroscopy is described

  2. Depth profiling of boron implanted silicon by positron beam

    International Nuclear Information System (INIS)

    Oevuenc, S.

    2004-01-01

    Positron depth profiling analyses of low energy implants of silicon aim to observe tbe structure and density of the vacancies generating by implantation and the effect of annealing. This work present the results to several set of data starting S and W parameters. Boron implanted Silicon samples with different implantation energies,20,22,24,and 26 keV are analyzed by Slow positron beam (0-40 keV and 10 5 e + /s )(Variable Energy Positron) at the Positron Centre Delf-HOLLAND

  3. Multitemporal Accuracy and Precision Assessment of Unmanned Aerial System Photogrammetry for Slope-Scale Snow Depth Maps in Alpine Terrain

    Science.gov (United States)

    Adams, Marc S.; Bühler, Yves; Fromm, Reinhard

    2017-12-01

    Reliable and timely information on the spatio-temporal distribution of snow in alpine terrain plays an important role for a wide range of applications. Unmanned aerial system (UAS) photogrammetry is increasingly applied to cost-efficiently map the snow depth at very high resolution with flexible applicability. However, crucial questions regarding quality and repeatability of this technique are still under discussion. Here we present a multitemporal accuracy and precision assessment of UAS photogrammetry for snow depth mapping on the slope-scale. We mapped a 0.12 km2 large snow-covered study site, located in a high-alpine valley in Western Austria. 12 UAS flights were performed to acquire imagery at 0.05 m ground sampling distance in visible (VIS) and near-infrared (NIR) wavelengths with a modified commercial, off-the-shelf sensor mounted on a custom-built fixed-wing UAS. The imagery was processed with structure-from-motion photogrammetry software to generate orthophotos, digital surface models (DSMs) and snow depth maps (SDMs). Accuracy of DSMs and SDMs were assessed with terrestrial laser scanning and manual snow depth probing, respectively. The results show that under good illumination conditions (study site in full sunlight), the DSMs and SDMs were acquired with an accuracy of ≤ 0.25 and ≤ 0.29 m (both at 1σ), respectively. In case of poorly illuminated snow surfaces (study site shadowed), the NIR imagery provided higher accuracy (0.19 m; 0.23 m) than VIS imagery (0.49 m; 0.37 m). The precision of the UASSDMs was 0.04 m for a small, stable area and below 0.33 m for the whole study site (both at 1σ).

  4. Electroacoustic Process Study of Plasma Sparker Under Different Water Depth

    KAUST Repository

    Huang, Yifan

    2015-01-05

    The plasma sparker has been applied in oceanic high-resolution seismic exploration for decades. Normally it is towed on the water surface. This is suitable for shallow water, but if the water depth is great, the resolution will decrease dramatically, especially in the horizontal direction. This paper proposes the concept of a deep-towed plasma sparker and presents an experimental study of plasma sparker performance in terms of electric parameters, bubble behavior, and acoustic characteristics. The results show that hydrostatic pressure at a source depth ranging from 1 to 2000 m has a negligible influence on the electric parameters but a strong influence on bubble behavior, wherein both the maximum bubble radius and oscillation period are decreased. The collapse pulse vanishes when the source depth reaches 1000 m or deeper, and no bubble oscillation can be distinguished. The source level (evaluated by the expansion pulse) is also decreased as the source depth increases; moreover, the greater the discharge energy, the smaller the source level loss. The discharge energy per electrode should be greater than 20 J for the deep-towed plasma sparker, which can make the source level loss induced by hydrostatic pressure smaller than the transmission loss. The fast Fourier transform (FFT) results show that the dominant energy is around 20 kHz, which is mainly induced by the expansion pulse and its oscillation. According to the simulation results, the fundamental frequency of the acoustic waveform increases with source depth in accord with a log linear trend, and also reaches tens of kilohertz in deep water. So, before the development of deep-towed plasma sparker, a new technical solution will need to be developed to solve this problem. © 1976-2012 IEEE.

  5. Anisotropy of the penetration depth in La2-xSrxCuO4 in underdoped and overdoped regions

    Science.gov (United States)

    Zaleski, A. J.; Klamut, J.

    1999-12-01

    We present the results of measurements of the penetration depth anisotropy in pulverized, ceramic La2-xSrxCuO4. The measurements were carried out for x = 0.08, 0.1, 0.125, 0.15 and 0.2. The powdered samples, immersed in wax, were magnetically oriented in a static magnetic field of 10 T. The penetration depth in the a-b plane, icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>ab, and perpendicular to it, icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>icons/Journals/Common/perp" ALT="perp" ALIGN="MIDDLE"/>, were derived from alternating-current susceptibility measurements. For underdoped samples they both vary linearly with temperature (for the low-temperature region), while for the samples from the overdoped region the measured points can be fitted by an exponential function. These results support Uemura's picture (Uemura Y J 1997 Physica C 282-287 194) of crossover from Bose-Einstein condensation to a Bardeen-Cooper-Schrieffer mechanism of superconductivity. The penetration depth values extrapolated to T = 0 may be described by a quadratic function of the strontium concentration (for both icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>ab and icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>icons/Journals/Common/perp" ALT="perp" ALIGN="MIDDLE"/>). The anisotropy of the penetration depth as a function of the substitution shows a similar dependence to the critical temperature Tc(x).

  6. Depth-encoded all-fiber swept source polarization sensitive OCT

    Science.gov (United States)

    Wang, Zhao; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Lee, ByungKun; Choi, WooJhon; Potsaid, Benjamin; Liu, Jonathan; Jayaraman, Vijaysekhar; Cable, Alex; Kraus, Martin F.; Liang, Kaicheng; Hornegger, Joachim; Fujimoto, James G.

    2014-01-01

    Polarization sensitive optical coherence tomography (PS-OCT) is a functional extension of conventional OCT and can assess depth-resolved tissue birefringence in addition to intensity. Most existing PS-OCT systems are relatively complex and their clinical translation remains difficult. We present a simple and robust all-fiber PS-OCT system based on swept source technology and polarization depth-encoding. Polarization multiplexing was achieved using a polarization maintaining fiber. Polarization sensitive signals were detected using fiber based polarization beam splitters and polarization controllers were used to remove the polarization ambiguity. A simplified post-processing algorithm was proposed for speckle noise reduction relaxing the demand for phase stability. We demonstrated systems design for both ophthalmic and catheter-based PS-OCT. For ophthalmic imaging, we used an optical clock frequency doubling method to extend the imaging range of a commercially available short cavity light source to improve polarization depth-encoding. For catheter based imaging, we demonstrated 200 kHz PS-OCT imaging using a MEMS-tunable vertical cavity surface emitting laser (VCSEL) and a high speed micromotor imaging catheter. The system was demonstrated in human retina, finger and lip imaging, as well as ex vivo swine esophagus and cardiovascular imaging. The all-fiber PS-OCT is easier to implement and maintain compared to previous PS-OCT systems and can be more easily translated to clinical applications due to its robust design. PMID:25401008

  7. Guam Commercial Fisheries BioSampling (CFBS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Guam Commercial Fisheries Biosampling program, which collects length and weight frequency data for whole commercial catches, and samples 4-8 species for in-depth...

  8. Improved depth estimation with the light field camera

    Science.gov (United States)

    Wang, Huachun; Sang, Xinzhu; Chen, Duo; Guo, Nan; Wang, Peng; Yu, Xunbo; Yan, Binbin; Wang, Kuiru; Yu, Chongxiu

    2017-10-01

    Light-field cameras are used in consumer and industrial applications. An array of micro-lenses captures enough information that one can refocus images after acquisition, as well as shift one's viewpoint within the sub-apertures of the main lens, effectively obtaining multiple views. Thus, depth estimation from both defocus and correspondence are now available in a single capture. And Lytro.Inc also provides a depth estimation from a single-shot capture with light field camera, like Lytro Illum. This Lytro depth estimation containing many correct depth information can be used for higher quality estimation. In this paper, we present a novel simple and principled algorithm that computes dense depth estimation by combining defocus, correspondence and Lytro depth estimations. We analyze 2D epipolar image (EPI) to get defocus and correspondence depth maps. Defocus depth is obtained by computing the spatial gradient after angular integration and correspondence depth by computing the angular variance from EPIs. Lytro depth can be extracted from Lyrto Illum with software. We then show how to combine the three cues into a high quality depth map. Our method for depth estimation is suitable for computer vision applications such as matting, full control of depth-of-field, and surface reconstruction, as well as light filed display

  9. Energy dependence of polymer gels in the orthovoltage energy range

    Directory of Open Access Journals (Sweden)

    Yvonne Roed

    2014-03-01

    Full Text Available Purpose: Ortho-voltage energies are often used for treatment of patients’ superficial lesions, and also for small- animal irradiations. Polymer-Gel dosimeters such as MAGAT (Methacrylic acid Gel and THPC are finding increasing use for 3-dimensional verification of radiation doses in a given treatment geometry. For mega-voltage beams, energy dependence of MAGAT has been quoted as nearly energy-independent. In the kilo-voltage range, there is hardly any literature to shade light on its energy dependence.Methods: MAGAT was used to measure depth-dose for 250 kVp beam. Comparison with ion-chamber data showed a discrepancy increasing significantly with depth. An over-response as much as 25% was observed at a depth of 6 cm.Results and Conclusion: Investigation concluded that 6 cm water in the beam resulted in a half-value-layer (HVL change from 1.05 to 1.32 mm Cu. This amounts to an effective-energy change from 81.3 to 89.5 keV. Response measurements of MAGAT at these two energies explained the observed discrepancy in depth-dose measurements. Dose-calibration curves of MAGAT for (i 250 kVp beam, and (ii 250 kVp beam through 6 cm of water column are presented showing significant energy dependence.-------------------Cite this article as: Roed Y, Tailor R, Pinksy L, Ibbott G. Energy dependence of polymer gels in the orthovoltage energy range. Int J Cancer Ther Oncol 2014; 2(2:020232. DOI: 10.14319/ijcto.0202.32 

  10. Turbulence Measurements from a Moored Platform at Mid-Depth in a Swift Tidal Channel

    Science.gov (United States)

    Hay, Alex; Lueck, Rolf; Wolk, Fabian; McMillan, Justine

    2014-05-01

    Results are presented from a turbulence experiment with a 3-m long streamlined floatation body, instrumented with velocity shear probes, fast-response thermistors, a 1 MHz Acoustic Doppler Current Profiler (AD2CP), and an Acoustic Doppler Velocimeter (ADV). The system was deployed over seven tidal cycles at mid-depth in a 30-m deep tidal channel in the lower Bay of Fundy, Canada. Peak flow speeds exceeded 2 m s-1, and while 10-min time scale average speeds were similar between ebb and flood, the variances were markedly higher during flood. Turbulent kinetic energy (TKE) dissipation rates measured with the shear probes exhibit a pronounced flood/ebb contrast: O(10-4) W kg-1 peak values during flood, but lower by an order of magnitude during ebb. Dissipation rates follow u3 scaling over a wide range of flow speeds between 0.5 and 2.5 m s-1. Below 0.5 m s-1 an asymmetry in the mounting arrangement caused the floatation body to pitch upward, biasing the measured dissipation values high. The ADV on the platform registered mean speed - used to implement Taylor's hypothesis - which was corroborated with the platform-mounted ADCP. Additional ADCPs were also deployed on a nearby bottom pod, sampling at turbulence resolving rates - up to 8 Hz. Comparisons between the shear probe and acoustic estimates of the TKE spectrum and dissipation rate - at comparable depths - are presented.

  11. Shifts in phylogenetic diversity of archaeal communities in mangrove sediments at different sites and depths in southeastern Brazil.

    Science.gov (United States)

    Mendes, Lucas William; Taketani, Rodrigo Gouvêa; Navarrete, Acácio Aparecido; Tsai, Siu Mui

    2012-06-01

    This study focused on the structure and composition of archaeal communities in sediments of tropical mangroves in order to obtain sufficient insight into two Brazilian sites from different locations (one pristine and another located in an urban area) and at different depth levels from the surface. Terminal restriction fragment length polymorphism (T-RFLP) of PCR-amplified 16S rRNA gene fragments was used to scan the archaeal community structure, and 16S rRNA gene clone libraries were used to determine the community composition. Redundancy analysis of T-RFLP patterns revealed differences in archaeal community structure according to location, depth and soil attributes. Parameters such as pH, organic matter, potassium and magnesium presented significant correlation with general community structure. Furthermore, phylogenetic analysis revealed a community composition distributed differently according to depth where, in shallow samples, 74.3% of sequences were affiliated with Euryarchaeota and 25.7% were shared between Crenarchaeota and Thaumarchaeota, while for the deeper samples, 24.3% of the sequences were affiliated with Euryarchaeota and 75.7% with Crenarchaeota and Thaumarchaeota. Archaeal diversity measurements based on 16S rRNA gene clone libraries decreased with increasing depth and there was a greater difference between depths (25% of sequences shared). Taken together, our findings indicate that mangrove ecosystems support a diverse archaeal community; it might possibly be involved in nutrient cycles and are affected by sediment properties, depth and distinct locations. Copyright © 2012 Institut Pasteur. Published by Elsevier Masson SAS. All rights reserved.

  12. Postnatal development of depth-dependent collagen density in ovine articular cartilage

    Directory of Open Access Journals (Sweden)

    Kranenbarg Sander

    2010-10-01

    Full Text Available Abstract Background Articular cartilage (AC is the layer of tissue that covers the articulating ends of the bones in diarthrodial joints. Adult AC is characterised by a depth-dependent composition and structure of the extracellular matrix that results in depth-dependent mechanical properties, important for the functions of adult AC. Collagen is the most abundant solid component and it affects the mechanical behaviour of AC. The current objective is to quantify the postnatal development of depth-dependent collagen density in sheep (Ovis aries AC between birth and maturity. We use Fourier transform infra-red micro-spectroscopy to investigate collagen density in 48 sheep divided over ten sample points between birth (stillborn and maturity (72 weeks. In each animal, we investigate six anatomical sites (caudal, distal and rostral locations at the medial and lateral side of the joint in the distal metacarpus of a fore leg and a hind leg. Results Collagen density increases from birth to maturity up to our last sample point (72 weeks. Collagen density increases at the articular surface from 0.23 g/ml ± 0.06 g/ml (mean ± s.d., n = 48 at 0 weeks to 0.51 g/ml ± 0.10 g/ml (n = 46 at 72 weeks. Maximum collagen density in the deeper cartilage increases from 0.39 g/ml ± 0.08 g/ml (n = 48 at 0 weeks to 0.91 g/ml ± 0.13 g/ml (n = 46 at 72 weeks. Most collagen density profiles at 0 weeks (85% show a valley, indicating a minimum, in collagen density near the articular surface. At 72 weeks, only 17% of the collagen density profiles show a valley in collagen density near the articular surface. The fraction of profiles with this valley stabilises at 36 weeks. Conclusions Collagen density in articular cartilage increases in postnatal life with depth-dependent variation, and does not stabilize up to 72 weeks, the last sample point in our study. We find strong evidence for a valley in collagen densities near the articular surface that is present in the youngest

  13. Development of the point-depletion code DEPTH

    International Nuclear Information System (INIS)

    She, Ding; Wang, Kan; Yu, Ganglin

    2013-01-01

    Highlights: ► The DEPTH code has been developed for the large-scale depletion system. ► DEPTH uses the data library which is convenient to couple with MC codes. ► TTA and matrix exponential methods are implemented and compared. ► DEPTH is able to calculate integral quantities based on the matrix inverse. ► Code-to-code comparisons prove the accuracy and efficiency of DEPTH. -- Abstract: The burnup analysis is an important aspect in reactor physics, which is generally done by coupling of transport calculations and point-depletion calculations. DEPTH is a newly-developed point-depletion code of handling large burnup depletion systems and detailed depletion chains. For better coupling with Monte Carlo transport codes, DEPTH uses data libraries based on the combination of ORIGEN-2 and ORIGEN-S and allows users to assign problem-dependent libraries for each depletion step. DEPTH implements various algorithms of treating the stiff depletion systems, including the Transmutation trajectory analysis (TTA), the Chebyshev Rational Approximation Method (CRAM), the Quadrature-based Rational Approximation Method (QRAM) and the Laguerre Polynomial Approximation Method (LPAM). Three different modes are supported by DEPTH to execute the decay, constant flux and constant power calculations. In addition to obtaining the instantaneous quantities of the radioactivity, decay heats and reaction rates, DEPTH is able to calculate the integral quantities by a time-integrated solver. Through calculations compared with ORIGEN-2, the validity of DEPTH in point-depletion calculations is proved. The accuracy and efficiency of depletion algorithms are also discussed. In addition, an actual pin-cell burnup case is calculated to illustrate the DEPTH code performance in coupling with the RMC Monte Carlo code

  14. Unsynchronized scanning with a low-cost laser range finder for real-time range imaging

    Science.gov (United States)

    Hatipoglu, Isa; Nakhmani, Arie

    2017-06-01

    Range imaging plays an essential role in many fields: 3D modeling, robotics, heritage, agriculture, forestry, reverse engineering. One of the most popular range-measuring technologies is laser scanner due to its several advantages: long range, high precision, real-time measurement capabilities, and no dependence on lighting conditions. However, laser scanners are very costly. Their high cost prevents widespread use in applications. Due to the latest developments in technology, now, low-cost, reliable, faster, and light-weight 1D laser range finders (LRFs) are available. A low-cost 1D LRF with a scanning mechanism, providing the ability of laser beam steering for additional dimensions, enables to capture a depth map. In this work, we present an unsynchronized scanning with a low-cost LRF to decrease scanning period and reduce vibrations caused by stop-scan in synchronized scanning. Moreover, we developed an algorithm for alignment of unsynchronized raw data and proposed range image post-processing framework. The proposed technique enables to have a range imaging system for a fraction of the price of its counterparts. The results prove that the proposed method can fulfill the need for a low-cost laser scanning for range imaging for static environments because the most significant limitation of the method is the scanning period which is about 2 minutes for 55,000 range points (resolution of 250x220 image). In contrast, scanning the same image takes around 4 minutes in synchronized scanning. Once faster, longer range, and narrow beam LRFs are available, the methods proposed in this work can produce better results.

  15. Depth-enhanced three-dimensional-two-dimensional convertible display based on modified integral imaging.

    Science.gov (United States)

    Park, Jae-Hyeung; Kim, Hak-Rin; Kim, Yunhee; Kim, Joohwan; Hong, Jisoo; Lee, Sin-Doo; Lee, Byoungho

    2004-12-01

    A depth-enhanced three-dimensional-two-dimensional convertible display that uses a polymer-dispersed liquid crystal based on the principle of integral imaging is proposed. In the proposed method, a lens array is located behind a transmission-type display panel to form an array of point-light sources, and a polymer-dispersed liquid crystal is electrically controlled to pass or to scatter light coming from these point-light sources. Therefore, three-dimensional-two-dimensional conversion is accomplished electrically without any mechanical movement. Moreover, the nonimaging structure of the proposed method increases the expressible depth range considerably. We explain the method of operation and present experimental results.

  16. Penetration-depth calculations in the ab and c directions in a layered S/N superconductor

    International Nuclear Information System (INIS)

    Atkinson, W.A.; Carbotte, J.P.

    1995-01-01

    We present the results of calculations of the penetration depths λ ab and λ c (the subscripts refer to the direction of the screening currents). Our model is a layered superconducting/normal metal (S/N) model, in which the two types of layers are stacked in alternating fashion. The S and N layers are coupled in a coherent fashion and the N layer is driven superconducting by a proximity effect. We calculate the penetration depths for both d-wave and s-wave order parameters for a range of interlayer coupling strengths, and we discuss the effect that the interlayer coupling has on the temperature dependence of the penetration depths. We finish by comparing our results with experimental observations of YBa 2 Cu 3 O 7

  17. Depth-Resolved Nanospray Desorption Electrospray Ionization Mass Spectrometry in Biofilms

    Science.gov (United States)

    2015-11-16

    metabolites and possibly proteins from biofilms at different depth. A microcapillary system was developed and tested for this goal. The...demonstrated that a dual microcapillary system can be used to collect nanoliter sample from the biofilms at 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND...Spectrometry in Biofilms The views, opinions and/or findings contained in this report are those of the author(s) and should not contrued as an official

  18. Nested, fixed-depth fluidic sampler supplementary testing - AEAT doc 2926-2-002

    International Nuclear Information System (INIS)

    REICH, F.R.

    1999-01-01

    This report summarizes the results of cold testing, completed by AEAT, as part of the proof-of-principle testing for a proposed nested, fixed-depth fluidic sampling system. This sampling system will provide waste samples from the PHMC feed tank to support the privatization contract with BNFL. Proof-of-principle tests were completed with 2 wt% and 10 wt% sand/water and 25 wt% kaolin clay/water simulants with a test setup that spanned the 24 ft to 57 ft height required in the feed tank. The tests demonstrated that the system could pump and sample waste materials with low and with high solids content. In addition, the tests demonstrated a need for some design upgrades to the sampling system, as there was material loss when the sample bottle was removed from the sampling needle. These were complementary tests, completed as part of an EM-50 Tank Focus Area (TFA) to develop a sampling system for validating LAW and HLW waste batches for the Privatization Contract

  19. Nested, fixed-depth fluidic sampler supplementary testing - AEAT doc 2926-2-002

    Energy Technology Data Exchange (ETDEWEB)

    REICH, F.R.

    1999-03-11

    This report summarizes the results of cold testing, completed by AEAT, as part of the proof-of-principle testing for a proposed nested, fixed-depth fluidic sampling system. This sampling system will provide waste samples from the PHMC feed tank to support the privatization contract with BNFL. Proof-of-principle tests were completed with 2 wt% and 10 wt% sand/water and 25 wt% kaolin clay/water simulants with a test setup that spanned the 24 ft to 57 ft height required in the feed tank. The tests demonstrated that the system could pump and sample waste materials with low and with high solids content. In addition, the tests demonstrated a need for some design upgrades to the sampling system, as there was material loss when the sample bottle was removed from the sampling needle. These were complementary tests, completed as part of an EM-50 Tank Focus Area (TFA) to develop a sampling system for validating LAW and HLW waste batches for the Privatization Contract.

  20. 14CO2 analysis of soil gas: Evaluation of sample size limits and sampling devices

    Science.gov (United States)

    Wotte, Anja; Wischhöfer, Philipp; Wacker, Lukas; Rethemeyer, Janet

    2017-12-01

    Radiocarbon (14C) analysis of CO2 respired from soils or sediments is a valuable tool to identify different carbon sources. The collection and processing of the CO2, however, is challenging and prone to contamination. We thus continuously improve our handling procedures and present a refined method for the collection of even small amounts of CO2 in molecular sieve cartridges (MSCs) for accelerator mass spectrometry 14C analysis. Using a modified vacuum rig and an improved desorption procedure, we were able to increase the CO2 recovery from the MSC (95%) as well as the sample throughput compared to our previous study. By processing series of different sample size, we show that our MSCs can be used for CO2 samples of as small as 50 μg C. The contamination by exogenous carbon determined in these laboratory tests, was less than 2.0 μg C from fossil and less than 3.0 μg C from modern sources. Additionally, we tested two sampling devices for the collection of CO2 samples released from soils or sediments, including a respiration chamber and a depth sampler, which are connected to the MSC. We obtained a very promising, low process blank for the entire CO2 sampling and purification procedure of ∼0.004 F14C (equal to 44,000 yrs BP) and ∼0.003 F14C (equal to 47,000 yrs BP). In contrast to previous studies, we observed no isotopic fractionation towards lighter δ13C values during the passive sampling with the depth samplers.