WorldWideScience

Sample records for same-day bidirectional endoscopy

  1. Organization and logistics of drug-induced sleep endoscopy in a training hospital.

    Science.gov (United States)

    Benoist, L B L; de Vries, N

    2015-09-01

    Drug-induced sleep endoscopy (DISE) is a rapidly growing method to evaluate airway collapse in patients receiving non-CPAP therapies for sleep-disordered breathing (SDB). The growing number of DISEs has consequences for the organization of clinical protocols. In this paper we present our recent experiences with DISE, performed by an ENT resident, with sedation given by a nurse anesthetist, in an outpatient endoscopy setting, while the staff member/sleep surgeon discusses the findings and the recommended treatment proposal on the same day.

  2. Same-day discharge after laparoscopic hysterectomy.

    Science.gov (United States)

    Perron-Burdick, Misa; Yamamoto, Miya; Zaritsky, Eve

    2011-05-01

    To estimate readmission rates and emergency care use by patients discharged home the same day after laparoscopic hysterectomy. This was a retrospective case series of patients discharged home the same-day after total or supracervical laparoscopic hysterectomy in a managed care setting. Chart reviews were performed for outcomes of interest which included readmission rates, emergency visits, and surgical and demographic characteristics. The two hysterectomy groups were compared using χ² tests for categorical variables and t tests or Wilcoxon rank-sum tests for continuously measured variables. One-thousand fifteen laparoscopic hysterectomies were performed during the 3-year study period. Fifty-two percent (n=527) of the patients were discharged home the same-day; of those, 46% (n=240) had total laparoscopic hysterectomies and 54% (n=287) had supracervical. Cumulative readmission rates were 0.6%, 3.6%, and 4.0% at 48 hours, 3 months, and 12 months, respectively. The most common readmission diagnoses included abdominal incision infection, cuff dehiscence, and vaginal bleeding. Less than 4% of patients presented for emergency care within 48 or 72 hours, most commonly for nausea or vomiting, pain, and urinary retention. Median uterine weight was 155 g, median blood loss was 70 mL, and median surgical time was 150 minutes. There was no difference in readmission rates or emergency visits for the total compared with the supracervical laparoscopic hysterectomy group. Same-day discharge after laparoscopic hysterectomy is associated with low readmission rates and minimal emergency visits in the immediate postoperative period. Same-day discharge may be a safe option for healthy patients undergoing uncomplicated laparoscopic hysterectomy.

  3. Transradial PCI and Same Day Discharge.

    Science.gov (United States)

    Elfandi, Ali; Safirstein, Jordan G

    2018-02-24

    The evolution of cardiac catheterization has led to the development of well-refined, more effective, and safer devices that allow cardiovascular interventionalists to deliver high-quality percutaneous interventions (PCI). Transradial PCI (TRI) has gained more popularity in the USA over the past 10 years, and as experience and volume of TRI grow, studies adopting same day radial PCI protocols have emerged and are showing promising results. We sought to review the current literature on TRI and same day discharge (SDD). This literature review was performed to evaluate the studies that were published over the last 17 years regarding TRI and SDD. A literature search using PubMed, Cochran database, Google Scholar, and Embase was performed for studies evaluating TRI and SDD from January 1, 2000, to August 1, 2017. Observational studies, randomized clinical trials, meta-analyses, and consensus statements were included in our review. We used the following terms in our search: "same day," "same day discharge," "outpatient," and "ambulatory radial PCI." Articles with data pertinent to the subject matter were included. We did not limit our searches to specific journals. The available literature supports SDD for selected radial PCI patients. The advancement in PCI devices and pharmacology has enhanced the safety of post-PCI disposition leading to the evolution from traditional overnight stays to the development of same day discharge programs. We conclude that outpatient TRI for appropriately selected patients will be the standard of care in the future. This will lead to increased patient satisfaction, improved hospital throughput, and reduced hospital costs, without increased procedural complications.

  4. Same-Day Versus Next-Day Repair of Fovea-Threatening Primary Rhegmatogenous Retinal Detachments.

    Science.gov (United States)

    Gorovoy, Ian R; Porco, Travis C; Bhisitkul, Robert B; de Juan, Eugene; Schwartz, Daniel M; Stewart, Jay M

    2016-01-01

    To evaluate the outcomes of same-day versus next-day repair of fovea-threatening rhegmatogenous retinal detachments (FT RRD). Retrospective, multi-surgeon observational case series. Operative reports and medical records were reviewed to evaluate a number of visual and anatomic outcomes, including presenting features, intraoperative complications, and postoperative results in the repair of primary FT RRD undergoing same-day versus next-day repair with scleral buckling, pars plana vitrectomy, or both procedures. A total of 96 consecutive patients (43 same-day, 45 next-day, and eight two days later) were compared. There was no statistically significant difference in visual outcomes between same-day and next-day repair at postoperative months 3 and 6 and at last follow-up (month 3 mean BCVA 20/30 same day; 20/32 next day; p = 0.82). Preoperative vision was strongly correlated with postoperative acuity. Effect of differences in length or type of visual symptoms, location of RRD, gender, or lens status on postoperative month 3 best-corrected visual acuity (BCVA) was not statistically significant. Overall, 85% of patients had a BCVA of 20/40 or better at postoperative month 3. Reoperation rate and intraoperative complications were not statistically different between the two groups. Re-attachment was achieved in all but one patient in both groups. Time in the operating room was longer for same-day surgery (2.98 ± 0.46 hours) compared to next-day surgery (2.54 ± 0.38 hours) (p factoring in the type of surgery performed. However, one case did progress to a macula-off detachment in a superior RRD with breaks found in lattice degeneration. Next-day surgery provided equivalent visual outcomes. Emergent, same-day surgery has logistical and resource implications as it may be more expensive, may necessitate rescheduling of previously booked cases, and may limit preoperative examination by the surgeon and perioperative team.

  5. Diagnosis of Adult Chronic Rhinosinusitis: Can Nasal Endoscopy Predict Intrasinus Disease?

    Directory of Open Access Journals (Sweden)

    Arif Ali Kolethekkat

    2013-11-01

    Full Text Available Objectives: To define the role of endoscopic evaluation of middle meatus in adult patients clinically diagnosed to have chronic rhino-sinusitis and its ability to predict intra-sinus mucosal involvement as compared to CT scan.Methods: This prospective analytical study was conducted on consecutive patients with diagnosis of chronic rhino-sinusitis who were symptomatic and fulfilled the American Academy of Otolaryngology - Head and Neck Surgery Task Force criteria. The patients were enrolled prospectively and were subjected to rigid diagnostic nasal endoscopy and classified as defined by the revised Sinus Allergy Health Partnership Task Force criteria. The patients then underwent non contrast CT sinuses on the same day. Results were analyzed as a diagnostic test evaluation using CT as a gold standard.Results: Among the 75 study patients with symptom based chronic rhino-sinusitis, nasal endoscopy was abnormal in 65 patients (87%. Of these patients, 60/65 (92% showed positive findings on CT scan. Ten patients had normal endoscopy, of these 6/10 (60% had abnormal CT scan. Sensitivity and specificity of diagnostic nasal endoscopy against CT scan were 91% (95% CI: 81-97 and 44% (95% CI: 14-79, respectively. The likelihood ratio for positive nasal endoscopy to diagnose chronic rhino-sinusitis was 1.6 and the likelihood ratio to rule out chronic rhino-sinusitis when endoscopy was negative was 0.2.Conclusion: Nasal endoscopy is a valid and objective diagnostic tool in the work up of patients with symptomatic chronic rhino-sinusitis. When clinical suspicion is low (90% of patients when clinical suspicion is high (88% as defined in this study by AAO-HNS Task Force criteria. Negative endoscopy, however, does not totally exclude the sinus disease in patients fulfilling task force criteria. CT scan may be needed on follow-up if there is clinical suspicion in 10% of these patients who are negative on endoscopy if symptoms persists. It is thus possible to reduce

  6.  Cost-effectiveness of medicine vs. endoscopy for dyspeptic patients

    DEFF Research Database (Denmark)

    Kjeldsen, Hans Christian; Lauritzen, Torsten; Christensen, Bo

      Background: Decision analyses conclude that empirical anti-secretory therapy is more cost-effective than endoscopy for managing patients with dyspepsia however RCTs including economic evaluation come to diverging results Aim: to compare the cost-effectiveness of two strategies for management.......   Results The incremental cost effectiveness (CE) ratio for one day free of dyspeptic symptoms using the endoscopy strategy was €/day 300 compared with the PPI strategy. The incremental CE ratio for one patient free of dyspeptic symptoms after one year using the endoscopy strategy was € 13,600 based....... The empirical PPI strategy was hence the more cost-effective strategy for managing patients with dyspepsia in general practice especially if reflux was the predominant symptom.  ...

  7. Nanotechnology in gastrointestinal endoscopy: A primer

    Directory of Open Access Journals (Sweden)

    Ashish Kumar Jha

    2012-01-01

    Full Text Available Nanotechnology is the understanding, control of matter and development of engineered devices in nanometer range (1-100 nm. Nanoparticles have different physicochemical properties (small size, large surface area to volume ratio, and high reactivity in comparison to bulk materials of the same composition. The nanotechnology has proved its usefulness in early diagnosis, proteonomics, imaging diagnostics and multifunctional therapeutics. Recent studies have shown its role in early diagnosis and targeted therapy of various gastrointestinal disorders such as hepatitis B virus and hepatitis C virus related liver disease, inflammatory bowel disease, gastric ulcer, and malignancy. Application of this technology appears promising in diagnostic and therapeutic endoscopy such as the endoscopic hemostasis of peptic ulcer bleeding, prevention of clogging of plastic stent and advance capsule endoscopy. This article will highlight the basic concepts of nanotechnology and its potential application in gastrointestinal endoscopy.

  8. SAME-DAY TRIPS: A CHANCE OF URBAN DESTINATION DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    Dario Simicevic

    2011-12-01

    Full Text Available The global economic crisis, the decline of standard and climatic factors influence the allocation of tourism trends at the global level. Certain types of tourist movements start up and develop; they have been present, but not sufficiently studied by authors. They also include a short trip or visit to a particular destination. Considering their characteristics, they do not require a lot of money and they make an increasingly important segment of the tourism market. Therefore, the importance of same-day trips should not be neglected on today's tourism market. Although in practice this part of the tourist offers and demand has not often been attached enough importance, same day trip can achieve a very significant inflow of funds and encourage the development of many potential tourist destinations. For all the reasons mentioned above, and because of its importance, the organization of same day-trips should be the fundamental basis and essential focus for tourism development. Taking into consideration that inbound tourist agencies show special interest for same-day trips, we have tried to give a starting point for further research in this part of the tourism market.

  9. Delayed bleeding and hemorrhage of mucosal defects after gastric endoscopic submucosal dissection on second-look endoscopy.

    Science.gov (United States)

    Ono, Shoko; Ono, Masayoshi; Nakagawa, Manabu; Shimizu, Yuichi; Kato, Mototsugu; Sakamoto, Naoya

    2016-04-01

    Although second-look endoscopy is performed within several days after gastric endoscopic submucosal dissection (ESD), there has been no evidence supporting the usefulness of the intervention. We investigated the relationship between delayed bleeding and hemorrhage of mucosal defects after ESD on second-look endoscopy and analyzed risk factors of active bleeding on second-look endoscopy. A total of 441 consecutive ESD cases with gastric cancer or adenoma were retrospectively analyzed. Second-look endoscopy was performed in the morning after the day of ESD. Bleeding of mucosal defects on second-look endoscopy was classified according to the Forrest classification, and active bleeding was defined as Forrest Ia or Ib. Delayed bleeding was defined as hematemesis or melena after second-look endoscopy. A total of 406 second-look endoscopies were performed, and delayed bleeding occurred in 11 patients. The incidence rate of delayed bleeding after second-look endoscopy in patients with Forrest Ia or Ib was significantly higher than that in patients with Forrest IIa, IIb or III (7.69 vs. 2.02 %, p 35 mm, the odds ratio of active bleeding on second-look endoscopy was 1.9. Active bleeding of mucosal defects on second-look endoscopy is a risk factor for delayed bleeding.

  10. Capsule Endoscopy

    Science.gov (United States)

    ... because experience with it is limited and traditional upper endoscopy is widely available. Why it's done Your doctor might recommend a capsule endoscopy procedure to: Find the cause of gastrointestinal bleeding. If you have unexplained bleeding in your digestive ...

  11. Studying and Incorporating Efficiency into Gastrointestinal Endoscopy Centers

    Directory of Open Access Journals (Sweden)

    Lukejohn W. Day

    2015-01-01

    Full Text Available Efficiency is defined as the use of resources in such a way as to maximize the production of goods and services. Improving efficiency has been the focus of management in many industries; however, it has not been until recently that incorporating efficiency models into healthcare has occurred. In particular, the study and development of improvement projects aimed at enhancing efficiency in GI have been growing rapidly in recent years. This focus on improving efficiency in GI has been spurred by the dramatic rise in the demand for endoscopic procedures as well as the rising number of insured patients requiring GI care coupled at the same time with limited resources in terms of staffing and space in endoscopy centers. This paper will critically review the history of efficiency in endoscopy centers, first by looking at other healthcare industries that have extensively studied and improved efficiency in their fields, examine a number of proposed efficiency metrics and benchmarks in endoscopy centers, and finally discuss opportunities where endoscopy centers could improve their efficiency.

  12. Robotics in endoscopy.

    Science.gov (United States)

    Klibansky, David; Rothstein, Richard I

    2012-09-01

    The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.

  13. Confocal laser endomicroscopy and ultrasound endoscopy during the same endoscopic session for diagnosis and staging of gastric neoplastic lesions.

    Science.gov (United States)

    Gheorghe, C; Iacob, R; Dumbrava, Mona; Becheanu, G; Ionescu, M

    2009-01-01

    Confocal LASER endomicroscopy (CLE) is a newly developed endoscopic technique which allows subsurface in vivo histological assessment during ongoing endoscopy and targeted biopsies. Ultrasound endoscopy (EUS) is a useful tool in staging upper GI malignant lesions. We describe for the first time the use of both techniques during the same endoscopic session, in a pilot study, in order to increase the diagnostic yield of histological assessment and provide the staging of the gastric neoplastic lesions thus decreasing the time to therapeutic decision. CLE has been performed with the Pentax EG-3870CIK confocal endomicroscope after a 5 ml intravenous 10% fluorescein injection; EUS has been performed subsequently, during the same endoscopic Propofol sedation session, using a standard radial EUS-scope. Eleven patients have been investigated, 4 females, 7 males, mean age 59.7 +/- 12.3 years. The indication of CLE/EUS exploration was the presence of a gastric polypoid lesion in 37% of cases, atypical gastric ulcer in 27% of patients, gastric lymphoma 18%, suspicion of gastric cancer recurrence after resection 9% and infiltrating type gastric cancer 9%. Histological assessment after targeted biopsy has established the diagnosis of gastric adenocarcinoma in 55% of cases, gastric lymphoma in 18% of cases, gastric adenoma, gastric GIST and gastric foveolar hyperplasia in 9% of cases respectively. CLE has allowed targeted biopsies in 81.8% of cases. In 2 patients - one case with suspected recurrent gastric cancer after surgery and one case of gastric lymphoma, CLE has indicated normal gastric mucosa. The EUS evaluation has shown TO lesion in two cases, T1 in 3 cases, T2 in 3 cases, T3 in one case. The EUS evaluation showed in one gastric lymphoma patient a lesion interesting the mucosa and submucosa with regional adenopathy and a submucosal lesion with regional adenopathy in the other gastric lymphoma case. The therapeutic decision was surgery in 73% of cases, chemotherapy and

  14. Endoscopy in pregnancy.

    LENUS (Irish Health Repository)

    O'mahony, Seamus

    2012-02-03

    Endoscopy is rarely required during pregnancy. The potential risks of endoscopy during pregnancy include foetal hypoxia due to sedative drugs and exposure to radiation. There is no evidence that endoscopy precipitates premature labour, and studies in this area have concluded that endoscopy during pregnancy is generally safe. There should be a strong indication for the procedure, which should be deferred whenever possible to the second trimester. Procedures should be performed without any sedation, or with the lowest dose of sedative medication. Radiation exposure should be kept to a minimum. Support should be obtained from specialists in obstetrics and anaesthesia. Indications for endoscopy during pregnancy are as follows: (1) gastroscopy: upper gastrointestinal bleeding, dysphagia, uncontrolled nausea\\/vomiting; (2) sigmoidoscopy\\/colonoscopy: rectal bleeding, diarrhoea; and (3) ERCP: choledocholithiasis, biliary pancreatitis. Sedative drugs, such as midazolam appear to be safe if used carefully. Radiation exposure during ERCP can be kept well below the danger level for teratogenicity.

  15. Technical endoscopy

    International Nuclear Information System (INIS)

    Cavalar, K.O.

    1988-01-01

    A survey is provided on different versions of endoscopes, taking into account the new developments of video endoscopy. With a variety of practical examples it is shown that technical tests using endoscopy are a demanding task for nondestructive testing, whose requirements can only be met on a customized basis. (orig./HP) [de

  16. Accuracy and consequences of same-day, invasive lung cancer workup

    DEFF Research Database (Denmark)

    Madsen, Kirsten Riis; Høegholm, Asbjørn; Bodtger, Uffe

    2016-01-01

    BACKGROUND: Though widely used, little is known about accuracy and efficacy of same-day, invasive workup of suspected lung cancer. OBJECTIVE: To evaluate the accuracy and efficacy of same-day, invasive lung cancer workup (diagnosis and mediastinal staging), and to identify differences between...... patients without (Group A) or with (Group B) need for resampling. METHODS: A retrospective study was performed on all consecutive patients referred for surgical treatment for localised lung cancer after invasive diagnostic and staging workup at our unit. Data were extracted from electronic medical files...... pulmonary disease. Tumour located in right upper lobe was associated with need for resampling. DISCUSSION: Our retrospective study suggests that same-day, invasive workup for lung cancer is safe, accurate, and efficacious in reducing time to therapy, even in patients with small lesions and low tumour burden....

  17. European Society of Gastrointestinal Endoscopy - Establishing the key unanswered research questions within gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Rees, Colin J; Ngu, Wee Sing; Regula, Jaroslaw

    2016-01-01

    Background and study aim: Gastrointestinal endoscopy is a rapidly evolving research field. The European Society of Gastrointestinal Endoscopy (ESGE) plays a key role in shaping opinion and endoscopy activity throughout Europe and further afield. Establishing key unanswered questions within the fi...

  18. The bidirectional effect between momentary affective states and exercise duration on a day level

    Directory of Open Access Journals (Sweden)

    Anna Schöndube

    2016-09-01

    Full Text Available Despite the well-documented positive effect of exercise on health outcomes, most people do not succeed in exercising regularly. In addition to several other influences, affective states seem to support exercise participation. Associations between exercise and affect have been shown in the laboratory. However, the dynamic relation between affect and exercise in daily life is not yet well understood. The objective of this study was to investigate the bi-directional effect of momentary affective states on naturally occurring exercise and vice versa in healthy participants in real-life environments by applying an ecological momentary assessment design. We hypothesized that (1 exercise duration is positively associated with affective states on a day level, (2 affective states in the morning predict subsequent exercise duration, and (3 exercise duration predicts affective states in the evening on that respective day. Data from N = 60 students aged between 19 and 32 years were analyzed. Affect and exercise duration were assessed daily over a period of 20 days via an electronic diary. Multilevel analysis revealed that positive affective valence was positively associated with exercise duration (p = 0.003 on a day level. In addition, the more the participants exercised that respective day, the better and more content they felt in the evening (p = 0.009. Energetic arousal in the morning significantly predicted subsequent exercise duration (p = 0.045. The findings indicate that it would be worthwhile to focus more on within-subject analyses when analyzing the dynamic relation between affect and exercise. Furthermore, affective states should be taken into account in creating effective interventions to foster exercise behavior and enhance maintenance.

  19. Endoscopy and autopsy follow-up of biodegradable oesophageal anastomoses in dogs.

    Science.gov (United States)

    Kovács, T; Németh, T; Orosz, Z; Köves, I

    2001-01-01

    The biofragmentable Anastomosis Ring (BAR) is a mechanical device composed of absorbable material and creates an inverting, atraumatic compressive anastomosis with no foreign material at the anastomotic site after healing. The aim of the present experimental study was to assess the safety of oesophagoscopy in early days after oesophageal anastomoses performed with the BAR and to follow-up the healing of BAR anastomoses by in vivo endoscopy and autopsy examination. Thirty mongrel dogs divided into subgroups according to the time-points of endoscopy and autopsy (4th, 7th, 14th, 28th day) were used. There was no significant difference in the healing of anastomoses performed under or above the tracheal bifurcation. Pleural adhesions helped to cover and seal small subclinical leaks. The mortality was 13.3% (4 dogs) and the overall leakage rate 14.3%. We looked for bleeding, haematoma, erosion, ulceration and granulation tissue in the anastomosis. Due to the high mechanical strength of these anastomoses, oesophagoscopy was a safe, easy and feasible method for follow-up BAR intrathoracic anastomoses, with no significant difference between the number of lesions found with endoscopy as compared to the autopsy data. The overall sensitivity of oesophagoscopy to discover mucosal lesions was 73.1%. Endoscopy had no complications, therefore it is a useful method of follow-up and may help predict the normal or compromised healing of oesophageal anastomoses.

  20. Risk Management for Gastrointestinal Endoscopy in Elderly Patients: Questionnaire for Patients Undergoing Gastrointestinal Endoscopy

    OpenAIRE

    Umegaki, Eiji; Abe, Shinya; Tokioka, Satoshi; Takeuchi, Nozomi; Takeuchi, Toshihisa; Yoda, Yukiko; Murano, Mitsuyuki; Higuchi, Kazuhide

    2009-01-01

    More elderly patients now undergo gastrointestinal endoscopy following recent advances in endoscopic techniques. In this study, we conducted a high-risk survey of endoscopies in Japan, using a questionnaire administered prior to upper gastrointestinal tract endoscopy (UGITE), and identified anticholinergic agents and glucagon preparations as high-risk premedication. We also evaluated the cardiovascular effects of anticholinergic agents and glucagon through measurements of plasma levels of hum...

  1. Utility of capsule endoscopy for evaluating anthelmintic efficacy in fully conscious dogs.

    Science.gov (United States)

    Lee, Alice C Y; Epe, Christian; Simpson, Kenneth W; Bowman, Dwight D

    2011-11-01

    The current accepted standard for evaluating the efficacy of gastrointestinal anthelmintic drugs is necropsy of infected animals followed by a comparison of worm counts between treated and non-treated groups. In this study capsule endoscopy, a minimally invasive method of imaging the small intestine of humans, is evaluated as a possible alternative to necropsy for the purposes of worm quantification in dogs. Eighteen Beagle dogs were included in this study. These dogs were part of a separate trial intended to determine the efficacy of various candidate parasiticides against Ancylostoma caninum via the necropsy standard. Dogs were inoculated with A. caninum L3s 4 weeks prior to treatment with one of the candidate compounds; a control group (n=8) received no treatment. Capsule endoscopy was performed 6-14 days post-treatment, followed by necropsy the following day. Seventeen dogs had complete examinations, i.e. the capsule traversed the small intestine and reached the colon within the battery life of the capsule. A strong correlation (r(s)=0.87, Pcapsule endoscopy and necropsy. There was no clear relationship between the ability of the capsule endoscope to detect hookworms and either visibility of the intestinal lumen or small intestinal transit time. Generation of a virtual spatial record of hookworm location from the capsule endoscopy data revealed a temporal trend, with the majority of worms present in the proximal small intestine in the morning versus the central to distal small intestine in the afternoon. Worm distribution as determined by capsule endoscopy closely resembled post-mortem findings. In conclusion, capsule endoscopy shows promise as an alternative to necropsy for the enumeration of A. caninum in the canine small intestine, although further work is required to improve completion rates and optimise intestinal examination. Copyright © 2011 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.

  2. Uncertainties in the Bidirectional Biodiesel Supply Chain

    NARCIS (Netherlands)

    Bot, Pieter; van Donk, Dirk Pieter; Pennink, Bartjan; Simatupang, Togar M.

    2015-01-01

    For remote areas, small-scale local biodiesel production is particularly attractive if producers and consumers are the same. Such supply chains are labeled as bidirectional. However, little is known on how raw material supply, transportation, logistics, production and operations uncertainties impact

  3. Endoscopy services in KwaZulu-Natal Province, South Africa, are insufficient for the burden of disease: Is patient care compromised?

    Science.gov (United States)

    Loots, E; Clarke, D L; Newton, K; Mulder, C J

    2017-10-31

    Endoscopy services are central to the diagnosis and management of many gastrointestinal (GI) diseases. To evaluate the adequacy of endoscopy services in the public sector hospitals of KwaZulu-Natal (KZN) Province, South Africa, in 2016. A cross-sectional study was performed using a questionnaire completed by the clinical heads of endoscopy units in the public hospitals in KZN. The heads of 11 of the 12 endoscopy units responded. Two units were in tertiary-level hospitals and nine in regional hospitals. A total of 22 353 endoscopic procedures were performed annually, averaging 2 032 cases per annum per centre; they were performed by 89 endoscopists, of whom 72 (80.1%) were general surgeons. There were 0.06 registered gastroenterologists (GEs) per 100 000 population. Each endoscopist performed an average of 263 endoscopies per annum. There were 1.18 endoscopy rooms available per unit, and two units had on-site fluoroscopy available. The average waiting period for an upper endoscopy was 27 (range 7 - 60) days, for colonoscopy 29 (range 7 - 90) days and for duodenoscopy/endoscopic retrograde cholangiopancreatography 13 (range 4 - 20) days. This included patients with alarm symptoms for GI cancers. Equipment breakages interrupted most services, except for one hospital that had a service contract. Unit heads cited lack of equipment, trained staff and maintenance contracts as major shortcomings. Endoscopy units in KZN are not adequately equipped to deal with the endoscopy workload and services are plagued by frequent disruptions, which impact negatively on service delivery. There is a need to train more GEs. Patient care is compromised in these public hospitals.

  4. Quality Improvement in Pediatric Endoscopy: A Clinical Report From the NASPGHAN Endoscopy Committee.

    Science.gov (United States)

    Kramer, Robert E; Walsh, Catharine M; Lerner, Diana G; Fishman, Douglas S

    2017-07-01

    The current era of healthcare reform emphasizes the provision of effective, safe, equitable, high-quality, and cost-effective care. Within the realm of gastrointestinal endoscopy in adults, renewed efforts are in place to accurately define and measure quality indicators across the spectrum of endoscopic care. In pediatrics, however, this movement has been less-defined and lacks much of the evidence-base that supports these initiatives in adult care. A need, therefore, exists to help define quality metrics tailored to pediatric practice and provide a toolbox for the development of robust quality improvement (QI) programs within pediatric endoscopy units. Use of uniform standards of quality reporting across centers will ensure that data can be compared and compiled on an international level to help guide QI initiatives and inform patients and their caregivers of the true risks and benefits of endoscopy. This report is intended to provide pediatric gastroenterologists with a framework for the development and implementation of endoscopy QI programs within their own centers, based on available evidence and expert opinion from the members of the NASPGHAN Endoscopy Committee. This clinical report will require expansion as further research pertaining to endoscopic quality in pediatrics is published.

  5. Virtual MR endoscopy of the ventricles prior to neurosurgical interventional endoscopy - evaluation of different presentation techniques

    International Nuclear Information System (INIS)

    Lemke, A.J.; Schurig-Urbaniak, A.M.; Niehues, S.M.; Felix, R.; Liebig, T.

    2004-01-01

    Purpose: In the past, virtual endoscopies have been performed for planning of endoscopic interventions or for diagnostic purposes in various organ systems with increasing frequency. This study evaluates the ability of virtual ventricular endoscopy to depict anatomical structures and the use for planning of real endoscopy. Materials and Methods: In a prospective study, 4 volunteers and 8 patients were examined with MRI. In 3 of the patients endoscopy was performed by our neurosurgeons thereafter. The calculation of the virtual endoscopy was based on 1 mm sagittal T2-weighted images. Comparison of surface rendering and volume rendering was made by means of video sequencing of individual views, and these were compared with the intraoperative endoscopic videos concerning the depictability of anatomical landmarks. Results: The reconstructions using volume rendering were more significant and easier to calculate than those based on surface rendering. Virtual endoscopy in the transparent mode allowed visualization of hazardous structures outside the ventricular system such as the basilar artery tip. Transparent 3D images of the ventricles gave a good overview on the depicted structures and enabled a better orientation during the virtual camera flight than surface rendered views. Conclusion: MR-based virtual endoscopy of the ventricular system can be obtained on the basis of surface- and volume-rendered views of sagittal T2-weighted thin sections. Preoperative utilization of this method simplifies the planning of endoscopy by visualization of anatomical structures. (orig.)

  6. Cecal perforation with an ascending colon cancer caused by upper gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Hiroyuki Miyatani

    2009-04-01

    Full Text Available Hiroyuki Miyatani1, Yukio Yoshida1, Hirokazu Kiyozaki21Department of Gastroenterology, Jichi Medical University, Saitama Medical Center, Saitama, Japan; 2Department of Surgery, Jichi Medical University, Saitama Medical Center, Saitama, JapanAbstract: Colonic perforation caused by upper gastrointestinal (GI endoscopy is extremely rare. A 69-year-old woman was referred to our hospital because of abdominal fullness. Colonoscopy could be performed only up to the hepatic flexure due to an elongated colon and residual stools. Because her symptoms improved, upper GI endoscopy was performed 11 days later. The patient developed severe abdominal pain two hours after the examination. Abdominal X-ray and computed tomography showed massive free air. Immediate laparotomy was performed for the intestinal perforation. After removal of stool, a perforation site was detected in the cecum with an invasive ascending colon cancer. Therefore, a right hemicolectomy, ileostomy, and transverse colostomy were performed. Although she developed postoperative septicemia, the patient was discharged 38 days after admission. Seven months postoperatively, the patient died of lung, liver, and brain metastases. Even in cases with a lesion that is not completely obstructed, it is important to note that air insufflations during upper GI endoscopy can perforate the intestinal wall in patients with advanced colon cancer.Keywords: colonic perforation, colon cancer, upper gastrointestinal endoscopy, fecal peritonitis

  7. Early Period Results and Clinical Characteristics of Upper Gastrointestinal Endoscopy in Sivrihisar State Hospital

    Directory of Open Access Journals (Sweden)

    Ozgur Turk

    2014-12-01

    Full Text Available Aim: Our aim was to identify the characteristics of the patient that performed upper gastrointestinal endoscopy in a new established endoscopy unit of a state hospital. We want to present the spectrum of gastrointestinal diseases in our hospitals region. Material and Method: We analyzed patients upper endoscopy results according to age, sex, complaints, clinical characteristics, type of anesthesia, and the necessity of biopsy. We reviewed 256 patients data between 2013 December-2014 July. All endoscopies were performed by same surgeon. Results: The highest complaint was epigastric pain (n=112, 43, 8%. Other complaints were followed as dyspepsia (n=84, 32.8%, heartburn (n=42, 16.4%, nausea (n=4, 1.6%, vomiting (n=2, 0.8%, dysphagia (n=6, 2.3%. We determined 218 gastritis (85.2%, 64 hiatal hernia (25%, 120 esophagitis (46.9%, 76 duodenitis (29.7%, 4 gastric ulcer (1.6%, 18 duodenal ulcers (7%, 20 bile reflux (7.8%, 26 Gastro esophageal reflux disease (GERD in patients (10.2%. 10 patients reported as normal (3.9%. Biopsy was performed in 186 of the patients. Discussion: Endoscopy can become an early diagnostic examination by increasing the availability of endoscopy. Also alarm symptoms should not be ignored and endoscopy should perform immediately in symptomatic patients. As an early result of upper gastrointestinal endoscopies that performed in this study; gastritis, esophagitis, duodenitis and hiatal hernia are common gastrointestinal diseases in our region.

  8. Reporting systems in gastrointestinal endoscopy: Requirements and standards facilitating quality improvement: European Society of Gastrointestinal Endoscopy position statement

    NARCIS (Netherlands)

    Bretthauer, Michael; Aabakken, Lars; Dekker, Evelien; Kaminski, Michal F.; Rösch, Thomas; Hultcrantz, Rolf; Suchanek, Stepan; Jover, Rodrigo; Kuipers, Ernst J.; Bisschops, Raf; Spada, Cristiano; Valori, Roland; Domagk, Dirk; Rees, Colin; Rutter, Matthew D.

    2016-01-01

    To develop standards for high quality of gastrointestinal endoscopy, the European Society of Gastrointestinal Endoscopy (ESGE) has established the ESGE Quality Improvement Committee. A prerequisite for quality assurance and improvement for all gastrointestinal endoscopy procedures is

  9. Dual-focus Magnification, High-Definition Endoscopy Improves Pathology Detection in Direct-to-Test Diagnostic Upper Gastrointestinal Endoscopy.

    Science.gov (United States)

    Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy

    2017-03-01

    In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.

  10. Outcome and safety of same-day-discharge percutaneous coronary interventions with femoral access

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Jensen, Lisette Okkels; Thayssen, Per

    2013-01-01

    Ongoing development in percutaneous coronary intervention (PCI) techniques and closing devices facilitates same-day-discharge in patients undergoing uncomplicated PCI procedures. We examined the safety and outcome in low-risk patients discharged the same day as PCI with femoral access was performed....

  11. Anesthesia related Complications in Pediatric GI Endoscopy

    Directory of Open Access Journals (Sweden)

    A Sabzevari

    2014-04-01

    Full Text Available Introduction: Elective upper and lower GI endoscopy is usually performed in children on an outpatient basis with the child under sedation or general anesthesia (GA. The objective of this study was to describe Anesthesia related complications in   children undergoing elective GI endoscopy.   Materials and Methods: The study design was descriptive on 1388 patients undergoing elective GI endoscopy in Sheikh Hospital from 2009 to 2013. All patient received propofol or standard inhalational anesthesia. We examined patients’ demographic data  ,  location of GI endoscopy ,  perioperative vital singe ,  recovery time , respiratory and cardiac complications , post operative nausea and vomiting , agitation , diagnosis and outcome   Results: Pediatric patients aged 2 to 17 years. 29 % of elective GI endoscopy was upper GI endoscopy and 70.3 % was lower GI endoscopy and 0.7 was both of them. 47.7 % of Pediatric patients were female and 52.3 % was male. We haven’t significant or fatal anesthesia related respiratory and cardiac complications (no apnea, no cardiac arrest. 8 patients (0.5% have transient bradicardia in post operative care Unit. 83 patients (5.9% have post operative nausea and vomiting controlled by medication.  6 patients (0.4% have post operative agitation controlled by medication.   Conclusions: General anesthesia and deep sedation in children undergoing elective GI endoscopy haven’t significant or fatal anesthesia related complications. We suggest Anesthesia for infants, young children, children with neurologic impairment, and some anxious older children undergoing elective GI endoscopy. Keyword: Anesthesia, Complication, Endoscopy, Pediatric.

  12. Postoperative Calcium Management in Same-Day Discharge Thyroid and Parathyroid Surgery.

    Science.gov (United States)

    Nelson, Kurt L; Hinson, Andrew M; Lawson, Bradley R; Middleton, Derek; Bodenner, Donald L; Stack, Brendan C

    2016-05-01

    To describe a safe and effective postoperative prophylactic calcium regimen for same-day discharge thyroid and parathyroid surgery. Case series with chart review. Tertiary referral academic institution. In total, 162 adult patients who underwent total thyroidectomy, completion thyroidectomy, unilateral parathyroidectomy, parathyroidectomy with bilateral neck exploration, or revision parathyroidectomy were identified preoperatively to be candidates for same-day discharge. All patients in this study were successfully discharged the same day on our standard prophylactic calcium regimen. Less than 1% (1/162) of patients re-presented to the hospital within 30 days of surgery, and that patient was successfully discharged from the emergency department after negative workup for hypocalcemia. There was no significant difference between preoperative and postoperative calcium levels in the total/completion thyroidectomy groups (9.3 vs 9.2 mg/dL, respectively; P = .14). The average postoperative calcium level in the parathyroid group was well within normal limits (9.5 mg/dL), and the difference in postoperative calcium levels between revision and primary parathyroidectomy cases was not significantly different (P = .34). The reported calcium regimen demonstrates a safe, effective, and objective means of postoperative calcium management in outpatient thyroid and parathyroid surgery in appropriately selected patients. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  13. Outcomes of Primary Unilateral Cheiloplasty in Same-Day Surgical Settings

    Directory of Open Access Journals (Sweden)

    Mansoor Khan

    2016-05-01

    Full Text Available BackgroundFinancial, clinical, and psychological considerations have made same-day surgery an attractive option for a variety of procedures. This article aimed to analyse the postoperative results of same-day primary unilateral cleft nasolabial repair.MethodsThis study was performed from 2011 to 2014. Unilateral cleft lip patients fulfilling the inclusion criteria were preoperatively classified as mild, moderate, and severe. All patients underwent same-day surgery and were discharged after satisfying the appropriate clinical criteria, receiving thorough counselling, and the establishment of a means of communication by phone. Postoperative outcomes were assessed and stratified according to preoperative severity and the type of repair.ResultsA total of 423 primary unilateral cleft lip patients were included. Fisher's anatomical subunit approximation technique was the most common procedure, followed by Noordhoff's technique. The postoperative outcome was good in 89.8% of cases, fair in 9.9% of cases, and poor in 0.2% of cases. The complication rate was 1.18% (n=5, and no instances of mortality were observed. The average hospital stay was 7.5 hours, leading to a cost reduction of 19% in comparison with patients who stayed overnight for observation.ConclusionsMild unilateral cleft lip was the most common deformity for which Fisher's anatomical subunit approximation technique was performed in most of the cases, with satisfactory postoperative outcomes. Refinements in the cleft rhinoplasty techniques over the course of the study improved the results regarding cleft nasal symmetry. Single-day primary unilateral cleft cheiloplasty was found to be a cost-effective procedure that did not pose an additional risk of complications.

  14. How to Improve the Quality of Screening Endoscopy in Korea: National Endoscopy Quality Improvement Program.

    Science.gov (United States)

    Cho, Yu Kyung

    2016-07-01

    In Korea, gastric cancer screening, either esophagogastroduodenoscopy or upper gastrointestinal series (UGIS), is performed biennially for adults aged 40 years or older. Screening endoscopy has been shown to be associated with localized cancer detection and better than UGIS. However, the diagnostic sensitivity of detecting cancer is not satisfactory. The National Endoscopy Quality Improvement (QI) program was initiated in 2009 to enhance the quality of medical institutions and improve the effectiveness of the National Cancer Screening Program (NCSP). The Korean Society of Gastrointestinal Endoscopy developed quality standards through a broad systematic review of other endoscopic quality guidelines and discussions with experts. The standards comprise five domains: qualifications of endoscopists, endoscopic unit facilities and equipment, endoscopic procedure, endoscopy outcomes, and endoscopic reprocessing. After 5 years of the QI program, feedback surveys showed that the perception of QI and endoscopic practice improved substantially in all domains of quality, but the quality standards need to be revised. How to avoid missing cancer in endoscopic procedures in daily practice was reviewed, which can be applied to the mass screening endoscopy. To improve the quality and effectiveness of NCSP, key performance indicators, acceptable quality standards, regular audit, and appropriate reimbursement are necessary.

  15. Clinical Efficacy of Proton Pump Inhibitor versus Prompt Endoscopy for Management of People with Dyspepsia

    DEFF Research Database (Denmark)

    Kjeldsen, Hans Christian; Lauritzen, Torsten; Christensen, Bo

      Title:   Clinical Efficacy of Proton Pump Inhibitor versus Prompt Endoscopy for Management of People with Dyspepsia: A Randomized Clinical Trial in General Practice.     Purpose: To compare the clinical efficacy of two strategies for management of dyspepsia in general practice in a RCT design.......   Setting: June 2000 to August 2002, 41 GPs, Aarhus County, Denmark   Methods: 368 people with dyspepsia (epigastric pain/discomfort, no alarm symptoms) were randomly assigned to treatment with omeprazol 40 mg/day for two weeks (PPI group, n:185) or endoscopy (endoscopy group, n:183). Due to migration......, dyspeptic contacts to GP or patients' satisfaction. Conclusions: Prompt endoscopy was superior to proton pump inhibitor concerning symptom improvement in management of dyspepsia in general practice when pain/discomfort was the primary symptom. There were no differences between the two strategies in respect...

  16. in upper gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Sinan Uzman

    2016-07-01

    Full Text Available Introduction : There is increasing interest in sedation for upper gastrointestinal endoscopy (UGE. Prospective randomized studies comparing sedation properties and complications of propofol and midazolam/meperidine in upper gastrointestinal endoscopy (UGE are few. Aim: To compare propofol and midazolam/meperidine sedation for UGE in terms of cardiopulmonary side effects, patient and endoscopist satisfaction and procedure-related times. Material and methods: This was a prospective, randomized, double-blind study of propofol versus midazolam and meperidine in 100 patients scheduled for diagnostic upper gastrointestinal endoscopy. The patients were divided into propofol and midazolam/meperidine groups. Randomization was generated by a computer. Cardiopulmonary side effects (hypotension, bradycardia, hypoxemia, procedure-related times (endoscopy time, awake time, time to hospital discharge, and patient and endoscopist satisfaction were compared between groups. Results: There was no significant difference between the groups with respect to the cost, endoscopy time, or demographic and clinical characteristics of the patients. Awake time and time to hospital discharge were significantly shorter in the propofol group (6.58 ±4.72 vs. 9.32 ±4.26 min, p = 0.030 and 27.60 ±7.88 vs. 32.00 ±10.54 min, p = 0.019. Hypotension incidence was significantly higher in the propofol group (12% vs. 0%, p = 0.027. The patient and endoscopist satisfaction was better with propofol. Conclusions : Propofol may be preferred to midazolam/meperidine sedation, with a shorter awake and hospital discharge time and better patient and endoscopist satisfaction. However, hypotension risk should be considered with propofol, and careful evaluation is needed, particularly in cardiopulmonary disorders.

  17. High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy.

    Science.gov (United States)

    Penny, Hugo A; Mooney, Peter D; Burden, Mitchell; Patel, Nisha; Johnston, Alexander J; Wong, Simon H; Teare, Julian; Sanders, David S

    2016-06-01

    Celiac disease remains underdiagnosed at endoscopy. We aimed to assess the utility of I-Scan (virtual chromo-endoscopy) to improve sensitivity of endoscopy to detect markers of villous atrophy in this condition. Patients from 2 UK hospitals were studied in 3 groups. Group 1: standard high definition, white light endoscopy (WLE); Group 2: WLE plus I-Scan; Group 3: non-high definition control group. The presence of endoscopic markers was recorded. At least 4 duodenal biopsies were taken from all patients. Serology was performed concurrently and observations were compared with histology. 758 patients (62% female, mean age 52) were recruited (Group 1: 230; Group 2: 228; Group 3: 300). 135 (17.8%) new diagnoses of coeliac disease were made (21 Group 1; 24 Group 2; 89 Group 3). The sensitivity for detection of endoscopic markers of villous atrophy was significantly higher in both Group 1 (85.7%, p=0.0004) and Group 2 (75%, p=0.005) compared to non-high definition controls (41.6%). There was no significant difference between high definition only and I-Scan groups (p=0.47). In non-high definition endoscopy a missed diagnosis was associated with lesser degrees of villous atrophy (p=0.019) and low tTG titre (p=0.007). High definition endoscopy with or without I-Scan increases the detection of celiac disease during routine endoscopy. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  18. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    Science.gov (United States)

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  19. Requirements and standards facilitating quality improvement for reporting systems in gastrointestinal endoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement

    NARCIS (Netherlands)

    Bretthauer, Michael; Aabakken, Lars; Dekker, Evelien; Kaminski, Michal F.; Rösch, Thomas; Hultcrantz, Rolf; Suchanek, Stepan; Jover, Rodrigo; Kuipers, Ernst J.; Bisschops, Raf; Spada, Cristiano; Valori, Roland; Domagk, Dirk; Rees, Colin; Rutter, Matthew D.

    2016-01-01

    To develop standards for high quality in gastrointestinal (GI) endoscopy, the European Society of Gastrointestinal Endoscopy (ESGE) has established the ESGE Quality Improvement Committee. A prerequisite for quality assurance and improvement for all GI endoscopy procedures is state-of-the-art

  20. "Ultra-rapid" sequential treatment in cholecystocholedocholithiasis: alternative same-day approach to laparoendoscopic rendezvous.

    Science.gov (United States)

    Borreca, Dario; Bona, Alberto; Bellomo, Maria Paola; Borasi, Andrea; De Paolis, Paolo

    2015-12-01

    There is still no consensus about timing of laparoscopic cholecystectomy after endoscopic retrograde cholangiopancreatography in the treatment of cholecystocholedocholithiasis. The aim of our retrospective study is to analyze the optimal timing of surgical treatment in patients presenting concurrent choledocholithiasis, choosing to perform a sequential endoscopic plus surgical approach, introducing a same-day two-stage alternative. All cases of cholecystocholedocholithiasis occurred between January 2007 and December 2014 in "Gradenigo" Hospital (Turin-Italy) were reviewed. Patients were divided into three groups, based on the timing of cholecystectomy after endoscopic retrograde cholangiopancreatography, and compared. Out of 2233 cholecystectomies performed in the mentioned time interval, have been identified 93 patients that fulfill the selection criteria. 36 patients were treated with a same-day approach, while 29 within first 72 h and 28 with delayed surgery. The overall length of stay was significantly lower in patients that were treated with a same-day approach (4.7 days), compared with other groups (p = 0.001), while no significant differences were found in terms of length of surgical intervention, intraoperative complications and conversions to open procedure, postoperative stay, morbidity and mortality. Patients treated with delayed surgery had a 18 % recurrency rate of biliary events, with an odds ratio of 14.13 (p = 0.018). Same-day two-stage approach should be performed in suitable patients at the index admission, reducing overall risks, improving the patients' quality-of-life, preventing recurrency, leading to a significant cost abatement; furthermore, this approach allows same outcomes of laparoendoscopic rendezvous, avoiding technical and organizational troubles.

  1. Leadership and team building in gastrointestinal endoscopy.

    Science.gov (United States)

    Valori, Roland M; Johnston, Deborah J

    2016-06-01

    A modern endoscopy service delivers high volume procedures that can be daunting, embarrassing and uncomfortable for patients [1]. Endoscopy is hugely beneficial to patients but only if it is performed to high standards [2]. Some consequences of poor quality endoscopy include worse outcomes for cancer and gastrointestinal bleeding, unnecessary repeat procedures, needless damage to patients and even avoidable death [3]. New endoscopy technology and more rigorous decontamination procedures have made endoscopy more effective and safer, but they have placed additional demands on the service. Ever-scarcer resources require more efficient, higher turnover of patients, which can be at odds with a good patient experience, and with quality and safety. It is clear from the demands put upon it, that to deliver a modern endoscopy service requires effective leadership and team working [4]. This chapter explores what constitutes effective leadership and what makes great clinical teams. It makes the point that endoscopy services are not usually isolated, independent units, and as such are dependent for success on the organisations they sit within. It will explain how endoscopy services are affected by the wider policy and governance context. Finally, within the context of the collection of papers in this edition of Best Practice & Research: Clinical Gastroenterology, it explores the potentially conflicting relationship between training of endoscopists and service delivery. The effectiveness of leadership and teams is rarely the subject of classic experimental designs such as randomized controlled trials. Nevertheless there is a substantial literature on this subject within and particularly outside healthcare [5]. The authors draw on this wider, more diffuse literature and on their experience of delivering a Team Leadership Programme (TLP) to the leaders of 70 endoscopy teams during the period 2008-2012. (Team Leadership Programme Link

  2. Endoscopy in Canada: Proceedings of the National Roundtable

    Directory of Open Access Journals (Sweden)

    Noah Switzer

    2015-01-01

    Full Text Available This 2014 roundtable discussion, hosted by the Canadian Association of General Surgeons, brought together general surgeons and gastroenterologists with expertise in endoscopy from across Canada to discuss the state of endoscopy in Canada. The focus of the roundtable was the evaluation of the competence of general surgeons at endoscopy, reviewing quality assurance parameters for high-quality endoscopy, measuring and assessing surgical resident preparedness for endoscopy practice, evaluating credentialing programs for the endosuite and predicting the future of endoscopic services in Canada. The roundtable noted several important observations. There exist inadequacies in both resident training and the assessment of competency in endoscopy. From these observations, several collaborative recommendations were then stated. These included the need for a formal and standardized system of both accreditation and training endoscopists.

  3. Analysis of the same day of the week increases in peak electricity ...

    African Journals Online (AJOL)

    in predicting the probability of exceedance (POE) levels of the same day of the ... ∗Department of Mathematical Statistics and Actuarial Science, University of the ... summary of the demand indices for each day of the week is shown in Table 1 ...

  4. Real-time holographic endoscopy

    Science.gov (United States)

    Smigielski, Paul; Albe, Felix; Dischli, Bernard

    1992-08-01

    Some new experiments concerning holographic endoscopy are presented. The quantitative measurements of deformations of objects are obtained by the double-exposure and double- reference beam method, using either a cw-laser or a pulsed laser. Qualitative experiments using an argon laser with time-average holographic endoscopy are also presented. A video film on real-time endoscopic holographic interferometry was recorded with the help of a frequency-doubled YAG-laser working at 25 Hz for the first time.

  5. Upper gastrointestinal endoscopy for dyspepsia: Εxploratory study of factors influencing patient compliance in Greece

    Directory of Open Access Journals (Sweden)

    Kouroumalis Elias

    2011-02-01

    Full Text Available Abstract Background Upper gastrointestinal endoscopy is the most preferable diagnostic examination for patients over fifty when upper gastrointestinal symptoms appear. However, limited knowledge exists in concerns to the compliance of primary care patients' to the doctors' recommendations for endoscopy. Methods Patients who visited primary care practices in Greece and experienced upper gastrointestinal symptoms within a 10 days screening study, were referred for an upper endoscopy exam. The patients which refused to complete the endoscopy exam, were interviewed by the use of an open- ended translated and validated questionnaire, the Identification of Dyspepsia in General Population (IDGP questionnaire. A qualitative thematic analysis grounded on the theory of planned behavior was performed to reveal the reasons for patients' refusal, while socio-demographic predictors were also assessed. Results Nine hundred and ninety two patients were recorded, 159 of them (16% were found positive for dyspepsia and gastro-esophageal reflux disease according to the IDGP questionnaire. Out of the above, 131 (83.6% patients refused further investigation with endoscopy. Patients who refused upper endoscopy were predominantly female (87.8% (p = 0.036 and over the age of 50. The lack of severe symptoms, fear of pain, concerns of sedation, comorbidity and competing life demands were reported by patients as barriers to performing an endoscopic investigation. Conclusions Patients with dyspepsia in rural Greece tend to avoid upper gastrointestinal endoscopy, with two major axons considered to be the causes of patients' refusal: their beliefs towards endoscopy and their personal capability to cope with it. Future research examining reasons of low compliance should be carried out in combination with modern behavioral theories so as to investigate into the above.

  6. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anesthesiologist administration of propofol for GI endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, J.M.; Riphaus, A.; Aparicio, J.R.

    2010-01-01

    Propofol sedation by non-anesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim of this evi......Propofol sedation by non-anesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim...... of this evidence- and consensus-based set of guideline is to provide non-anesthesiologists with a comprehensive framework for propofol sedation during digestive endoscopy. This guideline results from a collaborative effort from representatives of the European Society of Gastrointestinal Endoscopy (ESGE...

  7. Endoscopy and surgery for obesity

    International Nuclear Information System (INIS)

    Mejia, Andres Felipe; Unigarro, Ivan; Bolanos, Eduardo; Chaux, Carlos Felipe

    2006-01-01

    Actually bariatric surgery appears to be a secure, feasible and durable option for patients with morbid obesity. Most of the complications that arise from bariatric surgery can be solved with the use of endoscopy avoiding the morbidity and mortality of a surgical intervention. This group of patients has become a challenge for the endoscopist and favours the development of interventional endoscopy

  8. Capsule endoscopy: Beyond small bowel

    Directory of Open Access Journals (Sweden)

    Samuel N Adler

    2012-01-01

    Full Text Available In this article the brief and dramatic history of capsule endoscopy of the digestive tract is reviewed. Capsule endoscopy offers a non invasive method to diagnose diseases that affect the esophagus, small bowel and colon. Technological improvements relating to optics, software, data recorders with two way communication have revolutionized this field. These advancements have produced better diagnostic performance.

  9. Remote transmission of live endoscopy over the Internet: Report from the 87th Congress of the Japan Gastroenterological Endoscopy Society.

    Science.gov (United States)

    Shimizu, Shuji; Ohtsuka, Takao; Takahata, Shunichi; Nagai, Eishi; Nakashima, Naoki; Tanaka, Masao

    2016-01-01

    Live demonstration of endoscopy is one of the most attractive and useful methods for education and is often organized locally in hospitals. However, problems have been apparent in terms of cost, preparation, and potential risks to patients. Our aim was to evaluate a new approach to live endoscopy whereby remote hospitals are connected by the Internet for live endoscopic demonstrations. Live endoscopy was transmitted to the Congress of the Japan Gastroenterological Endoscopic Society by 13 domestic and international hospitals. Patients with upper and lower gastrointestinal diseases and with pancreatobiliary disorders were the subjects of a live demonstration. Questionnaires were distributed to the audience and were sent to the demonstrators. Questions concerned the quality of transmitted images and sound, cost, preparations, programs, preference of style, and adverse events. Of the audience, 91.2% (249/273) answered favorably regarding the transmitted image quality and 93.8% (259/276) regarding the sound quality. All demonstrators answered favorably regarding image quality and 93% (13/14) regarding sound quality. Preparations were completed without any outsourcing at 11 sites (79%) and were evaluated as 'very easy' or 'easy' at all but one site (92.3%). Preparation cost was judged as 'very cheap' or 'cheap' at 12 sites (86%). Live endoscopy connecting multiple international centers was satisfactory in image and sound quality for both audience and demonstrators, with easy and inexpensive preparation. The remote transmission of live endoscopy from demonstrators' own hospitals was preferred to the conventional style of locally organized live endoscopy. © 2015 The Authors Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  10. Planned second look endoscopy in patients with bleeding duodenal or gastric ulcers

    DEFF Research Database (Denmark)

    Trap, R; Skarbye, M; Rosenberg, J

    2000-01-01

    1998. Planned second look endoscopy and repeated sclerotherapy were standard care. The effects were evaluated by comparing the expected number of rebleeders with actual rebleeders. At the same time we assessed predicting factors for rebleeding. RESULTS: Fifteen of the admitted seventy patients were...... found to rebleed after initial sclerotherapy. The overall success rate of endoscopic therapy was 63/70 patients (90%). Six patients (9%) had to undergo surgery to obtain haemostasis, and one patient died suddenly after the second endoscopic sclerotherapy. Perforation was seen in two patients (3...... of the present study suggests a beneficial effect on rebleeding rate of patients treated with planned second look endoscopy. Future controlled trails should verify this hypothesis....

  11. Hindfoot endoscopy

    NARCIS (Netherlands)

    van Dijk, C. Niek

    2006-01-01

    Hindfoot pain can be caused by a variety of pathologies; most of these can be diagnosed and treated by means of endoscopy. The main indications are posterior tibial tenosynovectomy, diagnosis of a peroneus brevis length rupture, peroneal tendon athesiolysis, flexor hallucis longus release, os

  12. Virtual reality simulators for gastrointestinal endoscopy training.

    Science.gov (United States)

    Triantafyllou, Konstantinos; Lazaridis, Lazaros Dimitrios; Dimitriadis, George D

    2014-01-16

    The use of simulators as educational tools for medical procedures is spreading rapidly and many efforts have been made for their implementation in gastrointestinal endoscopy training. Endoscopy simulation training has been suggested for ascertaining patient safety while positively influencing the trainees' learning curve. Virtual simulators are the most promising tool among all available types of simulators. These integrated modalities offer a human-like endoscopy experience by combining virtual images of the gastrointestinal tract and haptic realism with using a customized endoscope. From their first steps in the 1980s until today, research involving virtual endoscopic simulators can be divided in two categories: investigation of the impact of virtual simulator training in acquiring endoscopy skills and measuring competence. Emphasis should also be given to the financial impact of their implementation in endoscopy, including the cost of these state-of-the-art simulators and the potential economic benefits from their usage. Advances in technology will contribute to the upgrade of existing models and the development of new ones; while further research should be carried out to discover new fields of application.

  13. Safety of bilateral same-day intravitreal injections of anti-vascular endothelial growth factor agents

    Directory of Open Access Journals (Sweden)

    Ruão M

    2017-02-01

    Full Text Available Miguel Ruão,1 María Andreu-Fenoll,2 Rosa Dolz-Marco,2 Roberto Gallego-Pinazo2 1Department of Ophthalmology, Centro Hospitalar Entre Douro e Vouga, Santa Maria da Feira, Portugal; 2Unit of Macula, Department of Ophthalmology, University and Polytechnic Hospital La Fe, Valencia, Spain Purpose: The aim was to evaluate the safety of bilateral same-day injections with intravitreal antiangiogenic drugs for macular diseases.Methods: Cross-sectional retrospective review of unilateral and bilateral same-day antiangiogenic injections was conducted between January 2011 and March 2016 in the Unit of Macula, University and Polytechnic Hospital La Fe (Valencia, Spain. A total of 8,172 injections were administered, among which 6,560 were unilateral and 1,612 were bilateral injections. Patients were included in the study regardless of the diagnosis. Ranibizumab and aflibercept were the antiangiogenic drugs used. The presence of endophthalmitis or retinal detachment was evaluated.Results: A total of 1 (0.012% culture-proven endophthalmitis and 19 (0.233% acute intraocular inflammations were registered. In the unilateral injections group, there were 18 (0.274% acute intraocular inflammations and 1 (0.015% culture-proven endophthalmitis. One (0.062% of the 1,612 bilateral same-day injections had a unilateral acute intraocular inflammation, and there were no culture-proven endophthalmitis in this group.Conclusion: Bilateral same-day injections are more convenient for patients and their caregivers than the unilateral injections administered on different days. In our study, the prevalence of culture-proven endophthalmitis and acute intraocular inflammation was lower in the bilateral injections than in the unilateral group. These data support the idea that bilateral same-day injections are a safe and valid treatment to use in our clinical practice. Keywords: bilateral, intravitreal, injections, anti-VEGF, endophthalmitis

  14. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anaesthesiologist administration of propofol for GI endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, J.M.; Riphaus, A.; Aparicio, J.R.

    2010-01-01

    ), the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA) and the European Society of Anaesthesiology (ESA). These three societies have endorsed the present guideline.The guideline is published simultaneously in the Journals Endoscopy and European Journal of Anaesthesiology....

  15. Outpatient vaginal hysterectomy: optimizing perioperative management for same-day discharge.

    Science.gov (United States)

    Zakaria, Mark A; Levy, Barbara S

    2012-12-01

    To present tactics for optimizing outpatient vaginal hysterectomy and describe perioperative outcomes in a large consecutive case series. This is a descriptive study and review of clinical outcomes in 1,071 patients selected to undergo vaginal hysterectomy for benign indications from 2000 to 2010. The setting is a single-surgeon private practice in a community hospital. Outcome measures include length of hospital stay, estimated blood loss, operative time, uterine weight, and perioperative complications, including hospital readmissions and emergency room visits. One thousand seventy-one of 1,162 cases (92%, 95% confidence interval [CI] 90.5-93.7) were total vaginal hysterectomies, of which 1,029 (96%, 95% CI 94.9-97.3) were discharged the same day after surgery. The median operative time was 34 minutes (range 17-210 minutes), and estimated blood loss was 45 mL (range 5-800 mL). The median patient age was 46 years (range 27-86 years), and median uterine weight was 160 g (range 25-1,380 g). One hundred ninety-three patients (18%, 95% CI 15.8-20.5) were nulliparous and 218 (20%, 95% CI 18-22.9) had prior pelvic surgery. Five patients (0.5%, 95% CI 0.2-1.1) required readmission or emergency room evaluation within the first 30 days. Vaginal hysterectomy can be successfully adopted as a same-day discharge procedure. In this population, regardless of previous pelvic surgery or nulliparity, good perioperative outcomes have been achieved.

  16. A simplified clinical risk score predicts the need for early endoscopy in non-variceal upper gastrointestinal bleeding.

    Science.gov (United States)

    Tammaro, Leonardo; Buda, Andrea; Di Paolo, Maria Carla; Zullo, Angelo; Hassan, Cesare; Riccio, Elisabetta; Vassallo, Roberto; Caserta, Luigi; Anderloni, Andrea; Natali, Alessandro

    2014-09-01

    Pre-endoscopic triage of patients who require an early upper endoscopy can improve management of patients with non-variceal upper gastrointestinal bleeding. To validate a new simplified clinical score (T-score) to assess the need of an early upper endoscopy in non variceal bleeding patients. Secondary outcomes were re-bleeding rate, 30-day bleeding-related mortality. In this prospective, multicentre study patients with bleeding who underwent upper endoscopy were enrolled. The accuracy for high risk endoscopic stigmata of the T-score was compared with that of the Glasgow Blatchford risk score. Overall, 602 patients underwent early upper endoscopy, and 472 presented with non-variceal bleeding. High risk endoscopic stigmata were detected in 145 (30.7%) cases. T-score sensitivity and specificity for high risk endoscopic stigmata and bleeding-related mortality was 96% and 30%, and 80% and 71%, respectively. No statistically difference in predicting high risk endoscopic stigmata between T-score and Glasgow Blatchford risk score was observed (ROC curve: 0.72 vs. 0.69, p=0.11). The two scores were also similar in predicting re-bleeding (ROC curve: 0.64 vs. 0.63, p=0.4) and 30-day bleeding-related mortality (ROC curve: 0.78 vs. 0.76, p=0.3). The T-score appeared to predict high risk endoscopic stigmata, re-bleeding and mortality with similar accuracy to Glasgow Blatchford risk score. Such a score may be helpful for the prediction of high-risk patients who need a very early therapeutic endoscopy. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  17. Efficacy and safety of flumazenil injection for the reversal of midazolam sedation after elective outpatient endoscopy.

    Science.gov (United States)

    Lee, Sang Pyo; Sung, In-Kyung; Kim, Jeong Hwan; Lee, Sun-Young; Park, Hyung Seok; Shim, Chan Sup

    2018-02-01

    Midazolam sedation during elective endoscopy is widely performed and flumazenil is frequently administered after endoscopy to reverse sedation in clinical practice. This study aimed to investigate the safety and efficacy of flumazenil injections after elective endoscopy under midazolam sedation. Participants who underwent an upper endoscopy under midazolam sedation were randomly divided into two groups. In group I, flumazenil was administered i.v. 10 min after the patient's transfer to the recovery room, and no antidote was injected in group II. The time of stay in the recovery room and adverse events were reviewed through the nursing records. We asked the patients about their pain and degree of satisfaction according to a visual analogue scale (VAS), their memory of the procedure, mental status and the presence of uncomfortable symptoms on the day of the procedure and the day afterwards. The length of stay in recovery was significantly shorter in group I than in group II. No significant differences were found in the number of patients with pain (VAS ≥1), adverse events and discomfort between the two groups. Additionally, there were no differences in the patients' memory of the procedure, satisfaction with sedation, willingness to repeat the endoscopy and mental status. The time in the recovery room after flumazenil administration was significantly shortened, and the use of the drug did not increase the risk of adverse events or discomfort. The use of flumazenil for reversing midazolam sedation seems to be safe and effective. © 2018 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  18. A Statistical Theory of Bidirectionality

    Science.gov (United States)

    DeLoach, Richard; Ulbrich, Norbert

    2013-01-01

    Original concepts related to the quantification and assessment of bidirectionality in strain-gage balances were introduced by Ulbrich in 2012. These concepts are extended here in three ways: 1) the metric originally proposed by Ulbrich is normalized, 2) a categorical variable is introduced in the regression analysis to account for load polarity, and 3) the uncertainty in both normalized and non-normalized bidirectionality metrics is quantified. These extensions are applied to four representative balances to assess the bidirectionality characteristics of each. The paper is tutorial in nature, featuring reviews of certain elements of regression and formal inference. Principal findings are that bidirectionality appears to be a common characteristic of most balance outputs and that unless it is taken into account, it is likely to consume the entire error budget of a typical balance calibration experiment. Data volume and correlation among calibration loads are shown to have a significant impact on the precision with which bidirectionality metrics can be assessed.

  19. Autofluorescence endoscopy: feasibility of detection of GI neoplasms unapparent to white light endoscopy with an evolving technology

    NARCIS (Netherlands)

    Haringsma, J.; Tytgat, G. N.; Yano, H.; Iishi, H.; Tatsuta, M.; Ogihara, T.; Watanabe, H.; Sato, N.; Marcon, N.; Wilson, B. C.; Cline, R. W.

    2001-01-01

    Case studies are presented of fluorescence endoscopy in the upper and lower GI tract to illustrate the ability to detect early-stage lesions that were not observable with white light endoscopy or those in which the assessment of the stage or extension of the lesion were equivocal. A new fluorescence

  20. Outcomes of patients hospitalized with peptic ulcer disease diagnosed in acute upper endoscopy.

    Science.gov (United States)

    Malmi, Hanna; Kautiainen, Hannu; Virta, Lauri J; Färkkilä, Martti A

    2017-11-01

    The incidence and complications of peptic ulcer disease (PUD) have declined, but mortality from bleeding ulcers has remained unchanged. The aims of the current study were to evaluate the significance of PUD among patients admitted for acute upper endoscopy and to evaluate the survival of PUD patients. In this prospective, observational cohort study, data on 1580 acute upper endoscopy cases during 2012-2014 were collected. A total of 649 patients were included with written informed consent. Data on patients' characteristics, living habits, comorbidities, drug use, endoscopy and short-term and long-term survival were collected. Of all patients admitted for endoscopy, 147/649 (23%) had PUD with the main symptom of melena. Of these PUD patients, 35% had major stigmata of bleeding (Forrest Ia-IIb) in endoscopy. Patients with major stigmata had significantly more often renal insufficiency, lower level of blood pressure with tachycardia and lower level of haemoglobin, platelets and ratio of thromboplastin time. No differences in drug use, Charlson comorbidity class, BMI, smoking or alcohol use were found. Of the PUD patients, 31% were Helicobacter pylori positive. The 30-day mortality was 0.7% (95% confidence interval: 0.01-4.7), 1-year mortality was 12.9% (8.4-19.5) and the 2-year mortality was 19.4% (13.8-26.8), with no difference according to major or minor stigmata of bleeding. Comorbidity (Charlson>1) was associated with decreased survival (P=0.029) and obesity (BMI≥30) was associated with better survival (P=0.023). PUD is still the most common cause for acute upper endoscopy with very low short-term mortality. Comorbidity, but not the stigmata of bleeding, was associated with decreased long-term survival.

  1. upper gastrointestinal endoscopy findings in patients referred

    African Journals Online (AJOL)

    2014-08-01

    Aug 1, 2014 ... Objective: To determine the pattern of referral and endoscopy ... build a model of a flexible fibre imaging device (2) ..... a retrospective and prospective audit of all upper ... endoscopy should be reserved for the high risk.

  2. Current status of cleaning and disinfection for gastrointestinal endoscopy in China: a survey of 122 endoscopy units.

    Science.gov (United States)

    Zhang, Xiuli; Kong, Jinyan; Tang, Ping; Wang, Shufang; Hyder, Qurratulain; Sun, Gang; Zhang, Rugang; Yang, Yunsheng

    2011-04-01

    Adequate compliance with the existing guidelines for cleaning and disinfection of gastrointestinal endoscopes and accessories is necessary to obtain high-level disinfection and prevent pathogen transmission. To investigate cleaning and disinfection practice in China. A questionnaire with 21 questions concerning gastrointestinal endoscopy reprocessing was sent by e-mail to 189 endoscopy units in China. One hundred and twenty-two (80.39%) of the 189 units responded. Compared with the low-workload units (disinfectant (88.5%) in all the units. In 23/122 (18.8%) units, the exposure time to glutaraldehyde was <45 min in the case of infectious disease patients. Eighty-six of 122 (70.5%) units reused disposable materials, of which 21/86 (24.4%) reused disposable forceps and disposable polypectomy hooks, and 2/86 (1.6%) reused disposable injection needles intermittently. Although gastrointestinal endoscopy has developed rapidly in China in the past decade, there is still room for improvement in the practice of endoscopy reprocessing, especially in middle-sized and small cities. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. Unsedated Flexible Upper Gastrointestinal Endoscopy: Need for ...

    African Journals Online (AJOL)

    Background: To determine the incidence of oxygen desaturation and whether routine oxygen monitoring is necessary during unsedated diagnostic flexible upper gastrointestinal endoscopy. Methods: A prospective study involving 54 consecutive in and out patients who had diagnostic upper gastrointestinal endoscopy at ...

  4. Factors impacting same-day cancellation of outpatient pediatric magnetic resonance imaging under anesthesia

    International Nuclear Information System (INIS)

    Hoffman, Andrea S.; Matlow, Anne; Shroff, Manohar; Cohen, Eyal

    2015-01-01

    Studies of elective surgical procedures indicate that cancellation is common and preventable. Little is known about cancellation of anesthesia-supported elective diagnostic imaging. To describe the reasons for same-day cancellation of MRI studies performed under sedation or anesthesia and identify patient characteristics associated with cancellations. This case-control study was carried out in a university-affiliated tertiary care children's hospital. Cases were defined as elective outpatient MRI studies booked under anesthesia that were cancelled after the patient had arrived in the radiology department in 2009. Matched controls were identified by selecting the same day and time 1 week before or after the cancelled case. Main outcome measures included demographics, MRI study characteristics, and social and medical factors. There were 111 outpatient anesthesia-supported MRI studies cancelled on the same day as the assessment (cancellation rate: 4.5%), of which 74.6% were related to family and patient factors, while 22% were related to system factors. Cancelled cases involved patients who lived in lower median income quintile neighborhoods compared to controls (2 vs. 3; P = 0.0007; odds ratio [OR] 3.81; 95% confidence interval [CI] 1.18-12.34). Those who traveled a greater median distance (in kilometers) were less likely to be cancelled (18.8 vs. 27.1, P = 0.0035). Although cancelled patients had a lower mean number of total medical services (2.5 vs. 3.0; P = 0.03; OR = 0.78; 95% CI 0.62-0.98), current medical factors (past 12 months) did not impact cancellations. Same-day cancellations of anesthesia-supported MRI studies are not uncommon, and the main predictor of cancellation seems to be socioeconomic rather than medical. (orig.)

  5. Factors impacting same-day cancellation of outpatient pediatric magnetic resonance imaging under anesthesia

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Andrea S. [University of Toronto, Department of Paediatrics, Division of Developmental Paediatrics, Holland Bloorview Kids Rehabilitation Hospital, Toronto (Canada); Matlow, Anne [University of Toronto, Strategic Initiatives, Postgraduate Medical Education, Toronto (Canada); Shroff, Manohar [University of Toronto, Department of Diagnostic Imaging, Division of Neuroradiology, Hospital for Sick Children, Toronto (Canada); Cohen, Eyal [University of Toronto, Division of Paediatric Medicine and Child Health Evaluative Sciences, Hospital for Sick Children, Department of Paediatrics and Institute of Health Policy, Management and Evaluation, Toronto (Canada)

    2014-07-24

    Studies of elective surgical procedures indicate that cancellation is common and preventable. Little is known about cancellation of anesthesia-supported elective diagnostic imaging. To describe the reasons for same-day cancellation of MRI studies performed under sedation or anesthesia and identify patient characteristics associated with cancellations. This case-control study was carried out in a university-affiliated tertiary care children's hospital. Cases were defined as elective outpatient MRI studies booked under anesthesia that were cancelled after the patient had arrived in the radiology department in 2009. Matched controls were identified by selecting the same day and time 1 week before or after the cancelled case. Main outcome measures included demographics, MRI study characteristics, and social and medical factors. There were 111 outpatient anesthesia-supported MRI studies cancelled on the same day as the assessment (cancellation rate: 4.5%), of which 74.6% were related to family and patient factors, while 22% were related to system factors. Cancelled cases involved patients who lived in lower median income quintile neighborhoods compared to controls (2 vs. 3; P = 0.0007; odds ratio [OR] 3.81; 95% confidence interval [CI] 1.18-12.34). Those who traveled a greater median distance (in kilometers) were less likely to be cancelled (18.8 vs. 27.1, P = 0.0035). Although cancelled patients had a lower mean number of total medical services (2.5 vs. 3.0; P = 0.03; OR = 0.78; 95% CI 0.62-0.98), current medical factors (past 12 months) did not impact cancellations. Same-day cancellations of anesthesia-supported MRI studies are not uncommon, and the main predictor of cancellation seems to be socioeconomic rather than medical. (orig.)

  6. Sensitivity of Non-Contrast Computed Tomography for Small Renal Calculi with Endoscopy as the Gold Standard.

    Science.gov (United States)

    Bhojani, Naeem; Paonessa, Jessica E; El Tayeb, Marawan M; Williams, James C; Hameed, Tariq A; Lingeman, James E

    2018-04-03

    To compare the sensitivity of non-contrast CT to endoscopy for detection of renal calculi. Imaging modalities for detection of nephrolithiasis have centered on abdominal x-ray (KUB), ultrasound (US), and non-contrast computed tomography (CT). Sensitivities of 58-62% (KUB), 45% (US), and 95-100% (CT) have been previously reported. However, these results have never been correlated with endoscopic findings. Idiopathic calcium oxalate stone formers with symptomatic calculi requiring ureteroscopy (URS) were studied. At the time of surgery, the number and location of all calculi within the kidney were recorded followed by basket retrieval. Each calculus was measured and sent for micro CT and infrared spectrophotometry. All CT scans were reviewed by the same genitourinary radiologist who was blinded to the endoscopic findings. The radiologist reported on the number, location, and size of each calculus. 18 renal units were studied in 11 patients. Average time from CT scan to URS was 28.6 days. The mean number of calculi identified per kidney was 9.2±6.1 for endoscopy and 5.9±4.1 for CT (p<0.004). The mean size of total renal calculi (sum of longest stone diameters) per kidney was 22.4±17.1 mm and 18.2±13.2 mm for endoscopy and CT, respectively (p=0.06). CT scan underreports the number of renal calculi, probably missing some small stones and unable to distinguish those lying in close proximity to one another. However, the total stone burden seen by CT is, on average, accurate when compared to that found on endoscopic examination. Copyright © 2018. Published by Elsevier Inc.

  7. The association between home care visits and same-day emergency department use: a case-crossover study.

    Science.gov (United States)

    Jones, Aaron; Schumacher, Connie; Bronskill, Susan E; Campitelli, Michael A; Poss, Jeffrey W; Seow, Hsien; Costa, Andrew P

    2018-04-30

    The extent to which home care visits contribute to the delay or avoidance of emergency department use is poorly characterized. We examined the association between home care visits and same-day emergency department use among patients receiving publicly funded home care. We conducted a population-based case-crossover study among patients receiving publicly funded home care in the Hamilton-Niagara-Haldimand-Brant region of Ontario between January and December 2015. Within individuals, all days with emergency department visits after 5 pm were selected as cases and matched with control days from the previous week. The cohort was stratified according to whether patients had ongoing home care needs ("long stay") or short-term home care needs ("short stay"). We used conditional logistical regression to estimate the association between receiving a home care visit during the day and visiting the emergency department after 5 pm on the same day. A total of 4429 long-stay patients contributed 5893 emergency department visits, and 2836 short-stay patients contributed 3476 visits. Receiving a home care nursing visit was associated with an increased likelihood of visiting the emergency department after 5 pm on the same day in both long-stay (odds ratio [OR] 1.32, 95% confidence interval [CI] 1.17-1.48) and short-stay patients (OR 1.22, 95% CI 1.07-1.39). Stronger associations were observed for less acute visits to the emergency department. No associations were observed for other types of home care visits. Patients receiving home care were more likely to visit the emergency department during the evening on days they received a nursing visit. The mechanism of the association between home care visits and same-day emergency department use and the extent to which same-day emergency department visits could be prevented or diverted require additional investigation. © 2018 Joule Inc. or its licensors.

  8. Appropriateness of upper-GI endoscopy: an Italian survey on behalf of the Italian Society of Digestive Endoscopy.

    Science.gov (United States)

    Hassan, Cesare; Bersani, Gianluca; Buri, Luigi; Zullo, Angelo; Anti, Marcello; Bianco, Maria Antonia; Di Giulio, Emilio; Ficano, Leonardo; Morini, Sergio; Di Matteo, Giovanni; Loriga, Piero; Pietropaolo, Vincenzo; Cipolletta, Livio; Costamagna, Guido

    2007-05-01

    Open-access endoscopy allows physicians to directly schedule endoscopic procedures for their patients without prior consultation. An evaluation of both appropriateness and diagnostic yield of endoscopic procedures is critical when assessing the costs and benefits of endoscopy in an open-access setting. The aim of this Italian multicenter study was to assess the appropriate use of upper endoscopy (EGD) in an open-access system and to establish the yield of diagnostic information relevant to patient care. Cross-sectional, prospective, multicenter study. A total of 6270 patients referred to 44 Italian centers for open-access EGD during 1 month were prospectively enrolled. The American Society for Gastrointestinal Endoscopy (ASGE) guidelines were used to assess the relation between the appropriate use of EGD and the presence of relevant endoscopic findings. The rate for "generally not indicated" EGDs was 22.9%: 29.4% for primary care physicians and 12.9% for specialists (P 20, 99% CI 3 to >100; P < .01). Open-access EGD is an useful procedure for clinical practice. Because most of the relevant findings were detected during examinations performed for appropriate indications, the use of ASGE guidelines emerges as crucial to the cost-effectiveness of an open-access system.

  9. Non-anesthesiologist administration of propofol for gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, Jean-Marc; Riphaus, Andrea; Schreiber, Florian

    2015-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE) and the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA). It addresses the administration of propofol by non-anesthesiologists for gastrointestinal (GI) endoscopy...... driving, drinking alcohol, operating heavy machinery, or engaging in legally binding decisions. Advice should be provided verbally and in written form to the patient, including a 24-hour contact phone number (strong recommendation, low quality evidence). 10 For patients of ASA classes 1 - 2 who have...

  10. Simultaneous functional photoacoustic and ultrasonic endoscopy of internal organs in vivo.

    Science.gov (United States)

    Yang, Joon-Mo; Favazza, Christopher; Chen, Ruimin; Yao, Junjie; Cai, Xin; Maslov, Konstantin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2012-08-01

    At present, clinicians routinely apply ultrasound endoscopy in a variety of interventional procedures that provide treatment solutions for diseased organs. Ultrasound endoscopy not only produces high-resolution images, but also is safe for clinical use and broadly applicable. However, for soft tissue imaging, its mechanical wave-based image contrast fundamentally limits its ability to provide physiologically specific functional information. By contrast, photoacoustic endoscopy possesses a unique combination of functional optical contrast and high spatial resolution at clinically relevant depths, ideal for imaging soft tissues. With these attributes, photoacoustic endoscopy can overcome the current limitations of ultrasound endoscopy. Moreover, the benefits of photoacoustic imaging do not come at the expense of existing ultrasound functions; photoacoustic endoscopy systems are inherently compatible with ultrasound imaging, thereby enabling multimodality imaging with complementary contrast. Here we present simultaneous photoacoustic and ultrasonic dual-mode endoscopy and show its ability to image internal organs in vivo, thus illustrating its potential clinical application.

  11. Feasibility and safety of same-day discharge after laparoscopic radical hysterectomy for cervix cancer.

    Science.gov (United States)

    Philp, Lauren; Covens, Allan; Vicus, Danielle; Kupets, Rachel; Pulman, Katherine; Gien, Lilian T

    2017-12-01

    To evaluate the safety and feasibility of same day-discharge (SDD) after laparoscopic radical hysterectomy for cervix cancer by determining complication rates and factors associated with post-operative admission. In this retrospective cohort study, patients undergoing laparoscopic radical hysterectomy for cervix cancer at a single institution from January 2006 to November 2015 were identified. Admitted patients were compared to same-day discharge patients. Rates of post-operative complications and readmission were analyzed and regression analysis used to determine factors associated with admission. 119 patients were identified. 75 (63%) were SDD patients (mean stay 156.7±50.2min) and 44 (37%) were admitted patients (mean stay 1.2±0.6days). Ten (13%) SDD patients sought medical attention within 30days post-operatively vs. nine (20%) admitted patients (p=0.17). Reasons SDD patients sought attention included pain (n=1), wound concerns (n=2), vaginal bleeding (n=2), DVT/VTE (n=1), fever (n=2) and fistula (n=2). All patients developed symptoms and presented between 5 and 13days post-operatively thus no complications could have been detected or prevented through initial admission. Four SDD patients were readmitted within 30days of surgery (p=0.25), two required re-operation (p=0.16). Admitted patients were older (p=0.049), had longer operations (p=0.02), increased blood loss (p=0.0004), increased intra-operative complications (p=0.001), surgery later in the day (p=0.004) and before April 2010 (p=0.001). On multivariate analysis, older age (OR1.05, p=0.03), surgery later in the day (OR 7.22, p=0.002) and presence of an intra-operative complication (OR 10.25, p=0.02) were significantly associated with admission. Same-day discharge after laparoscopic radical hysterectomy for cervix cancer is safe, with a low risk of post-operative morbidity and hospital readmission. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Jaw Dislocation as an Unusual Complication of Upper Endoscopy

    Directory of Open Access Journals (Sweden)

    Evan S. Dellon

    2016-05-01

    Full Text Available This case report presents an unusual complication of upper endoscopy, resulting in jaw dislocation. Temporomandibular joint dislocation is commonly reported in association with anesthesia and intubation, but it is not widely recognized as a complication of gastrointestinal endoscopy. This report also reviews the current literature regarding this complication and discusses the potential causes of dislocation, differential diagnoses for jaw pain following endoscopy, and recommendations for prevention.

  13. Potential impact of enhanced practice efficiency on endoscopy waiting times.

    LENUS (Irish Health Repository)

    Harewood, G C

    2009-06-01

    With the growing demand on endoscopy services, optimising practice efficiency has assumed increasing importance. Prior research has identified practice changes, which increase the efficiency in endoscopy. In this study, the potential impact of these practice changes on the current and projected future endoscopy waiting times at our institution was assessed.

  14. Endoscopy services in KwaZulu-Natal Province, South Africa, are ...

    African Journals Online (AJOL)

    There were 0.06 registered gastroenterologists (GEs) per 100 000 population. Each endoscopist performed an average of 263 endoscopies per annum. There were 1.18 endoscopy rooms available per unit, and two units had on-site fluoroscopy available. The average waiting period for an upper endoscopy was 27 (range 7 ...

  15. Photometric stereo endoscopy.

    Science.gov (United States)

    Parot, Vicente; Lim, Daryl; González, Germán; Traverso, Giovanni; Nishioka, Norman S; Vakoc, Benjamin J; Durr, Nicholas J

    2013-07-01

    While color video endoscopy has enabled wide-field examination of the gastrointestinal tract, it often misses or incorrectly classifies lesions. Many of these missed lesions exhibit characteristic three-dimensional surface topographies. An endoscopic system that adds topographical measurements to conventional color imagery could therefore increase lesion detection and improve classification accuracy. We introduce photometric stereo endoscopy (PSE), a technique which allows high spatial frequency components of surface topography to be acquired simultaneously with conventional two-dimensional color imagery. We implement this technique in an endoscopic form factor and demonstrate that it can acquire the topography of small features with complex geometries and heterogeneous optical properties. PSE imaging of ex vivo human gastrointestinal tissue shows that surface topography measurements enable differentiation of abnormal shapes from surrounding normal tissue. Together, these results confirm that the topographical measurements can be obtained with relatively simple hardware in an endoscopic form factor, and suggest the potential of PSE to improve lesion detection and classification in gastrointestinal imaging.

  16. Same-day {sup 90}Y radioembolization: implementing a new treatment paradigm

    Energy Technology Data Exchange (ETDEWEB)

    Gabr, Ahmed; Kallini, Joseph Ralph; Gates, Vanessa L.; Hickey, Ryan; Desai, Kush; Thornburg, Bartley; Marshall, Karen; Salzig, Krystina; Williams, Melissa; Del Castillo, Carlene; Hohlastos, Elias; Lewandowski, Robert J. [Northwestern Memorial Hospital, Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology, Chicago, IL (United States); Kulik, Laura; Ganger, Daniel [Northwestern University, Department of Medicine, Division of Hepatology, Chicago, IL (United States); Baker, Talia [Northwestern University, Department of Surgery, Division of Transplantation, Comprehensive Transplant Center, Chicago, IL (United States); Salem, Riad [Northwestern Memorial Hospital, Robert H. Lurie Comprehensive Cancer Center, Department of Radiology, Section of Interventional Radiology, Chicago, IL (United States); Northwestern University, Department of Surgery, Division of Transplantation, Comprehensive Transplant Center, Chicago, IL (United States); Robert H. Lurie Comprehensive Cancer Center, Northwestern University, Department of Medicine, Division of Hematology and Oncology, Chicago, IL (United States)

    2016-12-15

    To assess the feasibility of conducting pretreatment mesenteric angiography, coil embolization, {sup 99m}Tc macroaggregated albumin ({sup 99m}Tc-MAA) scintigraphy, and {sup 90}Y radioembolization treatment in a single, same-day, combined outpatient encounter. This was a retrospective study of 78 patients treated during the period 2008 - 2015 who were managed in a single outpatient encounter under the guidance of the Interventional Radiology Department and The Nuclear Medicine Department. Pretreatment planning was performed by reviewing baseline imaging and estimated perfused liver volume bearing the tumor. The region of interest was estimated using 3-D software; this value was used for dosimetry planning. Maximum lung shunting fractions of 10 % for hepatocellular carcinoma and 5 % for liver metastases were assumed. Subsequently, hepatic angiography and {sup 99m}Tc-MAA scintigraphy were performed followed by {sup 90}Y treatment in one outpatient encounter. Total in-room procedure time was recorded. All patients underwent same-day angiography, {sup 99m}Tc-MAA scintigraphy and {sup 90}Y radioembolization. Of the 78 patients, 16 received multiple segmental treatments to both lobes, 44 received treatment to the right lobe, and 18 received treatment to the left lobe. The median dose was 106 Gy. The median number of {sup 90}Y vials needed was two (range one to six). The median in-room time was 160 min (75 - 250 min). The residential status of the patients was as follows, 18 % (14/78) were local residents, 55 % (43/78) traveled from outside the city limits, 18 % (14/78) were from out-of-state, and 9 % (7/78) were resident abroad. Of the 78 patients, 61 (77 %) had hepatocellular carcinoma, and 17 (22 %) had liver metastases. The median lung dose was 3.5 Gy. This study demonstrated the feasibility of same-day {sup 90}Y evaluation and treatment while maintaining the principles of safe and effective {sup 90}Y infusion including tumoricidal dosimetry (lobar, segmentectomy

  17. Virtual endoscopy in neurosurgery: a review.

    Science.gov (United States)

    Neubauer, André; Wolfsberger, Stefan

    2013-01-01

    Virtual endoscopy is the computerized creation of images depicting the inside of patient anatomy reconstructed in a virtual reality environment. It permits interactive, noninvasive, 3-dimensional visual inspection of anatomical cavities or vessels. This can aid in diagnostics, potentially replacing an actual endoscopic procedure, and help in the preparation of a surgical intervention by bridging the gap between plain 2-dimensional radiologic images and the 3-dimensional depiction of anatomy during actual endoscopy. If not only the endoscopic vision but also endoscopic handling, including realistic haptic feedback, is simulated, virtual endoscopy can be an effective training tool for novice surgeons. In neurosurgery, the main fields of the application of virtual endoscopy are third ventriculostomy, endonasal surgery, and the evaluation of pathologies in cerebral blood vessels. Progress in this very active field of research is achieved through cooperation between the technical and the medical communities. While the technology advances and new methods for modeling, reconstruction, and simulation are being developed, clinicians evaluate existing simulators, steer the development of new ones, and explore new fields of application. This review introduces some of the most interesting virtual reality systems for endoscopic neurosurgery developed in recent years and presents clinical studies conducted either on areas of application or specific systems. In addition, benefits and limitations of single products and simulated neuroendoscopy in general are pointed out.

  18. Cerebral gas embolism due to upper gastrointestinal endoscopy

    NARCIS (Netherlands)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A.; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E.

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of

  19. Cerebral gas embolism due to upper gastrointestinal endoscopy

    NARCIS (Netherlands)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A.; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E.

    2009-01-01

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of

  20. Endoscopy versus radiology in post-procedural monitoring after peroral endoscopic myotomy (POEM).

    Science.gov (United States)

    Nast, Jan Friso; Berliner, Christoph; Rösch, Thomas; von Renteln, Daniel; Noder, Tania; Schachschal, Guido; Groth, Stefan; Ittrich, Harald; Kersten, Jan F; Adam, Gerhard; Werner, Yuki B

    2018-03-15

    The newly developed technique of peroral endoscopic myotomy (POEM) has been shown to be effective in several short- and mid-term studies. Limited information is available about the adequacy of immediate post-POEM monitoring tests. POEM was performed under general anesthesia in 228 patients (59.6% male, mean age 45.6 ± 15.5 years). Post-procedural checks comprised clinical and laboratory examination, and, during post-procedure days 1-5, endoscopy and-in the first 114 cases-radiologic examination using water-soluble contrast (1st group); the remaining patients underwent post-procedure controls without radiology (2nd group). Main outcome was value of endoscopic compared to radiologic control for recognition of early adverse events. In the first group, routine fluoroscopic contrast swallow suggested minor leakages at the mucosal entry site in two cases which was confirmed endoscopically in only one. Endoscopy revealed two minor entry site leakages and, in six additional cases, dislocated clips without leakage (overall 5.3%). All eight patients underwent reclipping and healed without clinical sequelae. In the 2nd group, endoscopy showed 5 clip dislocations (all reclipped) and one ischemic cardiac perforation in a patient with clinical deterioration on post-POEM day 1 who had to undergo surgery after confirmation of leakage by CT. Radiologic monitoring (contrast swallow) after POEM is not useful and can be omitted. Even routine endoscopic monitoring for detection and closure of minor defects of the mucosal entry site yields limited information with regards to final outcome; major complications are very rare and probably associated with clinical deterioration. Clinical Trials Gov Registration number of the main study: NCT01405417.

  1. Analysis of the same day of the week increases in peak electricity ...

    African Journals Online (AJOL)

    Modelling of the same day of the week increases in peak electricity demand improves the reliability of a power network if an accurate assessment of the level and frequency of future extreme load forecasts is carried out. Key words: Gibbs sampling, generalized single pareto, generalized pareto distribution, pareto quantile ...

  2. Endoscopic non-technical skills team training: the next step in quality assurance of endoscopy training.

    Science.gov (United States)

    Matharoo, Manmeet; Haycock, Adam; Sevdalis, Nick; Thomas-Gibson, Siwan

    2014-12-14

    To investigate whether novel, non-technical skills training for Bowel Cancer Screening (BCS) endoscopy teams enhanced patient safety knowledge and attitudes. A novel endoscopy team training intervention for BCS teams was developed and evaluated as a pre-post intervention study. Four multi-disciplinary BCS teams constituting BCS endoscopist(s), specialist screening practitioners, endoscopy nurses and administrative staff (A) from English BCS training centres participated. No patients were involved in this study. Expert multidisciplinary faculty delivered a single day's training utilising real clinical examples. Pre and post-course evaluation comprised participants' patient safety awareness, attitudes, and knowledge. Global course evaluations were also collected. Twenty-three participants attended and their patient safety knowledge improved significantly from 43%-55% (P ≤ 0.001) following the training intervention. 12/41 (29%) of the safety attitudes items significantly improved in the areas of perceived patient safety knowledge and awareness. The remaining safety attitude items: perceived influence on patient safety, attitudes towards error management, error management actions and personal views following an error were unchanged following training. Both qualitative and quantitative global course evaluations were positive: 21/23 (91%) participants strongly agreed/agreed that they were satisfied with the course. Qualitative evaluation included mandating such training for endoscopy teams outside BCS and incorporating team training within wider endoscopy training. Limitations of the study include no measure of increased patient safety in clinical practice following training. A novel comprehensive training package addressing patient safety, non-technical skills and adverse event analysis was successful in improving multi-disciplinary teams' knowledge and safety attitudes.

  3. Diagnostic Yield of Microscopic Colitis in Open Access Endoscopy Center.

    Science.gov (United States)

    Ellingson, Derek; Miick, Ronald; Chang, Faye; Hillard, Robert; Choudhary, Abhishek; Ashraf, Imran; Bechtold, Matthew; Diaz-Arias, Alberto

    2011-08-01

    The diagnostic yield in open access endoscopy has been evaluated which generally support the effectiveness and efficiency of open access endoscopy. With a few exceptions, diagnostic yield studies have not been performed in open access endoscopy for more specific conditions. Therefore, we conducted a study to determine the efficiency of open access endoscopy in the detection of microscopic colitis as compared to traditional referral via a gastroenterologist. A retrospective search of the pathology database at the University of Missouri for specimens from a local open access endoscopy center was conducted via SNOMED code using the terms: "microscopic", "lymphocytic", "collagenous", "spirochetosis", "focal active colitis", "melanosis coli" and "histopathologic" in the diagnosis line for the time period between January 1, 2004 and May 25, 2006. Specimens and colonoscopy reports were reviewed by a single pathologist. Of 266 consecutive patients with chronic diarrhea and normal colonoscopies, the number of patients with microscopic disease are as follows: Lymphocytic colitis (n = 12, 4.5%), collagenous colitis (n = 17, 6.4%), focal active colitis (n = 15, 5.6%), and spirochetosis (n = 2, 0.4%). The diagnostic yield of microscopic colitis in this study of an open access endoscopy center does not differ significantly from that seen in major medical centers. In terms of diagnostic yield, open access endoscopy appears to be as effective in diagnosing microscopic colitis.

  4. Capsule endoscopy in the diagnosis of Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Niv Y

    2013-05-01

    Full Text Available Yaron NivDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, Petah Tikva, IsraelAbstract: Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing

  5. Bidirectional optical rotation of cells

    Directory of Open Access Journals (Sweden)

    Jiyi Wu

    2017-08-01

    Full Text Available Precise and controlled rotation manipulation of cells is extremely important in biological applications and biomedical studies. Particularly, bidirectional rotation manipulation of a single or multiple cells is a challenge for cell tomography and analysis. In this paper, we report an optical method that is capable of bidirectional rotation manipulation of a single or multiple cells. By launching a laser beam at 980 nm into dual-beam tapered fibers, a single or multiple cells in solutions can be trapped and rotated bidirectionally under the action of optical forces. Moreover, the rotational behavior can be controlled by altering the relative distance between the two fibers and the input optical power. Experimental results were interpreted by numerical simulations.

  6. Magnetically guided capsule endoscopy.

    Science.gov (United States)

    Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M

    2017-08-01

    Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.

  7. Comparative analyses of bidirectional promoters in vertebrates

    Directory of Open Access Journals (Sweden)

    Taylor James

    2008-05-01

    Full Text Available Abstract Background Orthologous genes with deep phylogenetic histories are likely to retain similar regulatory features. In this report we utilize orthology assignments for pairs of genes co-regulated by bidirectional promoters to map the ancestral history of the promoter regions. Results Our mapping of bidirectional promoters from humans to fish shows that many such promoters emerged after the divergence of chickens and fish. Furthermore, annotations of promoters in deep phylogenies enable detection of missing data or assembly problems present in higher vertebrates. The functional importance of bidirectional promoters is indicated by selective pressure to maintain the arrangement of genes regulated by the promoter over long evolutionary time spans. Characteristics unique to bidirectional promoters are further elucidated using a technique for unsupervised classification, known as ESPERR. Conclusion Results of these analyses will aid in our understanding of the evolution of bidirectional promoters, including whether the regulation of two genes evolved as a consequence of their proximity or if function dictated their co-regulation.

  8. Integrating high dimensional bi-directional parsing models for gene mention tagging.

    Science.gov (United States)

    Hsu, Chun-Nan; Chang, Yu-Ming; Kuo, Cheng-Ju; Lin, Yu-Shi; Huang, Han-Shen; Chung, I-Fang

    2008-07-01

    Tagging gene and gene product mentions in scientific text is an important initial step of literature mining. In this article, we describe in detail our gene mention tagger participated in BioCreative 2 challenge and analyze what contributes to its good performance. Our tagger is based on the conditional random fields model (CRF), the most prevailing method for the gene mention tagging task in BioCreative 2. Our tagger is interesting because it accomplished the highest F-scores among CRF-based methods and second over all. Moreover, we obtained our results by mostly applying open source packages, making it easy to duplicate our results. We first describe in detail how we developed our CRF-based tagger. We designed a very high dimensional feature set that includes most of information that may be relevant. We trained bi-directional CRF models with the same set of features, one applies forward parsing and the other backward, and integrated two models based on the output scores and dictionary filtering. One of the most prominent factors that contributes to the good performance of our tagger is the integration of an additional backward parsing model. However, from the definition of CRF, it appears that a CRF model is symmetric and bi-directional parsing models will produce the same results. We show that due to different feature settings, a CRF model can be asymmetric and the feature setting for our tagger in BioCreative 2 not only produces different results but also gives backward parsing models slight but constant advantage over forward parsing model. To fully explore the potential of integrating bi-directional parsing models, we applied different asymmetric feature settings to generate many bi-directional parsing models and integrate them based on the output scores. Experimental results show that this integrated model can achieve even higher F-score solely based on the training corpus for gene mention tagging. Data sets, programs and an on-line service of our gene

  9. New techniques for evaluating the gastrointestinal tract: capsular endoscopy

    Directory of Open Access Journals (Sweden)

    A E Karateyev

    2009-01-01

    Full Text Available The paper describes a procedure for capsular endoscopy (CE, a new high-technology method of evaluating the small bowel, and reports on its use in rheumatological care. Small bowel involvement is noted to be frequently encountered in rheumatic diseases, such as Behcet's disease, diffuse scleroderma, and seronegative spondylitis. According to the data of clinical trials, CE is effective in timely detecting this visceral abnormality. At the same time, CE is actually the only accurate method of diagnosing drug-induced enteropathy, a potentially menacing disease that frequently occurs with the use of nonsteroidal anti-inflammatory drugs.

  10. Patterns of nonemergent visits to different healthcare facilities on the same day: a nationwide analysis in Taiwan.

    Science.gov (United States)

    Wu, Meng-Hsuan; Wu, Meng-Ju; Chou, Li-Fang; Chen, Tzeng-Ji

    2014-01-01

    Doctor shopping is a common phenomenon in many countries. However, patterns of switching healthcare facilities on the same day were little known. The data were obtained from the longitudinal cohort datasets (LHID2010) of Taiwan's National Health Insurance Research Database in 2010. Of 1,000,000 persons of the cohort with 13,276,928 nonemergent visits, 185,347 patients had visited different healthcare facilities within one day, with a total of 672,478 visits and 337,260 switches between facilities in 329,073 patient-days. While 63.0% (n = 212,590) of all switches occurred between facilities of the same accreditation level, 14.1% (n = 47,664) moved from lower to higher level, and 22.8% (n = 77,006) moved in the opposite direction. In 33,689 switches, patients moved to the same specialty of another facility. In 48,324 switches, patients moved to another facility with the same diagnosis, and the most frequent diagnoses were diseases of the digestive system (11,148) and diseases of the respiratory system (10,393). In a densely populated country without strict referral regulation, a high percentage of Taiwanese people had the experience of visiting different healthcare facilities on the same day. The system of family physicians as personal doctors and gatekeepers to healthcare might ameliorate the harmful impact.

  11. Arteriovenous Malformation Detected by Small Bowel Endoscopy

    Directory of Open Access Journals (Sweden)

    Takaaki Fujii

    2014-10-01

    Full Text Available Gastrointestinal bleeding that originates in the small intestine is often difficult to diagnose. When successful diagnosis reveals a lesion that can be localized preoperatively, the laparoscopic approach is an appropriate and beneficial treatment modality for small bowel resection. A 69-year-old man presented with a 6-month history of gastrointestinal bleeding and symptomatic transfusion-dependent anemia. Upper and lower endoscopy were normal. Double-balloon endoscopy established the source of the bleeding as a 0.5-cm polypoid mass appearing as a submucosal tumor with redness and pulsation in the lower ileum, suggesting a vascular lesion. Laparoscopic small bowel resection was successful in removing the mass in the ileum. Histological evaluation of the mass revealed an arteriovenous malformation. Preoperative small bowel endoscopy can be useful for diagnosing the cause and localization of arteriovenous malformation in the small intestine.

  12. Implementation of a 'lean' cytopathology service: towards routine same-day reporting.

    Science.gov (United States)

    Hewer, Ekkehard; Hammer, Caroline; Fricke-Vetsch, Daniela; Baumann, Cinzia; Perren, Aurel; Schmitt, Anja M

    2018-05-01

    To systematically assess the effects of a Lean management intervention in an academic cytopathology service. We monitored outcomes including specimen turnaround times during stepwise implementation of a lean cytopathology workflow for gynaecological and non-gynaecological cytology. The intervention resulted in a major reduction of turnaround times for both gynaecological (3rd quartile 4.1 vs 2.3 working days) and non-gynaecological cytology (3rd quartile 1.9 vs. 1.2 working days). Introduction of fully electronic reporting had additional effect over continuous staining of slides alone. The rate of non-gynaecological specimens reported the same day increased from 4.5% to 56.5% of specimens received before noon. Lean management principles provide a useful framework for organization of a cytopathology workflow. Stepwise implementation beginning with a simplified gynaecological cytology workflow allowed involved staff to monitor the effects of individual changes and allowed for a smooth transition. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. What we have learned and what to expect from capsule endoscopy.

    Science.gov (United States)

    Adler, Samuel N; Bjarnason, Ingvar

    2012-10-16

    Capsule endoscopy was conceived by Gabriel Iddan and Paul Swain independently two decades ago. These applications include but are not limited to Crohn's disease of the small bowel, occult gastrointestinal bleeding, non steroidal anti inflammatory drug induced small bowel disease, carcinoid tumors of the small bowel, gastro intestinal stromal tumors of the small bowel and other disease affecting the small bowel. Capsule endoscopy has been compared to traditional small bowel series, computerized tomography studies and push enteroscopy. The diagnostic yield of capsule endoscopy has consistently been superior in the diagnosis of small bowel disease compared to the competing methods (small bowel series, computerized tomography, push enteroscopy) of diagnosis. For this reason capsule endoscopy has enjoyed a meteoric success. Image quality has been improved with increased number of pixels, automatic light exposure adaptation and wider angle of view. Further applications of capsule endoscopy of other areas of the digestive tract are being explored. The increased transmission rate of images per second has made capsule endoscopy of the esophagus a realistic possibility. Technological advances that include a double imager capsule with a nearly panoramic view of the colon and a variable frame rate adjusted to the movement of the capsule in the colon have made capsule endoscopy of the colon feasible. The diagnostic rate for the identification of patients with polyps equal to or larger than 6 mm is high. Future advances in technology and biotechnology will lead to further progress. Capsule endoscopy is following the successful modern trend in medicine that replaces invasive tests with less invasive methodology.

  14. From POEM to POET: Applications and perspectives for submucosal tunnel endoscopy.

    Science.gov (United States)

    Chiu, Philip W Y; Inoue, Haruhiro; Rösch, Thomas

    2016-12-01

    Recent advances in submucosal endoscopy have unlocked a new horizon for potential development in diagnostic and therapeutic endoscopy. Increasing evidence has demonstrated that peroral endoscopic myotomy (POEM) is not only clinically feasible and safe, but also has excellent results in symptomatic relief of achalasia. The success of submucosal endoscopy in performance of tumor resection has confirmed the potential of this new area in diagnostic and therapeutic endoscopy. This article reviews the current applications and evidence, from POEM to peroral endoscopic tunnel resection (POET), while exploring the possible future clinical applications in this field. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Patterns of Nonemergent Visits to Different Healthcare Facilities on the Same Day: A Nationwide Analysis in Taiwan

    Directory of Open Access Journals (Sweden)

    Meng-Hsuan Wu

    2014-01-01

    Full Text Available Doctor shopping is a common phenomenon in many countries. However, patterns of switching healthcare facilities on the same day were little known. The data were obtained from the longitudinal cohort datasets (LHID2010 of Taiwan’s National Health Insurance Research Database in 2010. Of 1,000,000 persons of the cohort with 13,276,928 nonemergent visits, 185,347 patients had visited different healthcare facilities within one day, with a total of 672,478 visits and 337,260 switches between facilities in 329,073 patient-days. While 63.0% (n=212,590 of all switches occurred between facilities of the same accreditation level, 14.1% (n=47,664 moved from lower to higher level, and 22.8% (n=77,006 moved in the opposite direction. In 33,689 switches, patients moved to the same specialty of another facility. In 48,324 switches, patients moved to another facility with the same diagnosis, and the most frequent diagnoses were diseases of the digestive system (11,148 and diseases of the respiratory system (10,393. In a densely populated country without strict referral regulation, a high percentage of Taiwanese people had the experience of visiting different healthcare facilities on the same day. The system of family physicians as personal doctors and gatekeepers to healthcare might ameliorate the harmful impact.

  16. Bi-directional associations between psychological arousal, cortisol, and sleep

    DEFF Research Database (Denmark)

    Garde, Anne Helene; Albertsen, Karen; Persson, Roger

    2012-01-01

    The aim was to elucidate the possible bi-directional relation between daytime psychological arousal, cortisol, and self-reported sleep in a group of healthy employees in active employment. Logbook ratings of sleep (Karolinska Sleep Questionnaire), stress, and energy, as well as positive...... and negative experiences in work and private life, were collected together with salivary cortisol over 3 days (n = 265). Higher bedtime ratings of stress and problems during the day were associated with morning ratings of poor sleep. Poorer morning ratings of sleep were associated with higher ratings of stress...... and problems during the day. The results underpin the possibility that arousal and poor sleep might create a self-reinforcing vicious circle that negatively affects a person's well-being....

  17. Apport de l'endoscopie digestive dans l'hypertension portale de l ...

    African Journals Online (AJOL)

    ... le rôle de l'endoscopie dans le traitement et la surveillance. Méthodes: Notre étude est une analyse rétrospective de 135 endoscopies digestives hautes effectuées chez 68 enfants atteints d'hypertension portale sur une période de 8 ans. Résultats: L'endoscopie a permis de mettre en évidence les varices oesogastriques ...

  18. Transnasal endoscopy: Technical considerations, advantages and limitations.

    Science.gov (United States)

    Atar, Mustafa; Kadayifci, Abdurrahman

    2014-02-16

    Transnasal endoscopy (TNE) is an upper endoscopy method which is performed by the nasal route using a thin endoscope less than 6 mm in diameter. The primary goal of this method is to improve patient tolerance and convenience of the procedure. TNE can be performed without sedation and thus eliminates the risks associated with general anesthesia. In this way, TNE decreases the cost and total duration of endoscopic procedures, while maintaining the image quality of standard caliber endoscopes, providing good results for diagnostic purposes. However, the small working channel of the ultra-thin endoscope used for TNE makes it difficult to use for therapeutic procedures except in certain conditions which require a thinner endoscope. Biopsy is possible with special forceps less than 2 mm in diameter. Recently, TNE has been used for screening endoscopy in Far East Asia, including Japan. In most controlled studies, TNE was found to have better patient tolerance when compared to unsedated endoscopy. Nasal pain is the most significant symptom associated with endoscopic procedures but can be reduced with nasal pretreatment. Despite the potential advantage of TNE, it is not common in Western countries, usually due to a lack of training in the technique and a lack of awareness of its potential advantages. This paper briefly reviews the technical considerations as well as the potential advantages and limitations of TNE with ultra-thin scopes.

  19. Transnasal endoscopy: Technical considerations, advantages and limitations

    Science.gov (United States)

    Atar, Mustafa; Kadayifci, Abdurrahman

    2014-01-01

    Transnasal endoscopy (TNE) is an upper endoscopy method which is performed by the nasal route using a thin endoscope less than 6 mm in diameter. The primary goal of this method is to improve patient tolerance and convenience of the procedure. TNE can be performed without sedation and thus eliminates the risks associated with general anesthesia. In this way, TNE decreases the cost and total duration of endoscopic procedures, while maintaining the image quality of standard caliber endoscopes, providing good results for diagnostic purposes. However, the small working channel of the ultra-thin endoscope used for TNE makes it difficult to use for therapeutic procedures except in certain conditions which require a thinner endoscope. Biopsy is possible with special forceps less than 2 mm in diameter. Recently, TNE has been used for screening endoscopy in Far East Asia, including Japan. In most controlled studies, TNE was found to have better patient tolerance when compared to unsedated endoscopy. Nasal pain is the most significant symptom associated with endoscopic procedures but can be reduced with nasal pretreatment. Despite the potential advantage of TNE, it is not common in Western countries, usually due to a lack of training in the technique and a lack of awareness of its potential advantages. This paper briefly reviews the technical considerations as well as the potential advantages and limitations of TNE with ultra-thin scopes. PMID:24567791

  20. Bidirectional waveguide coupling with plasmonic Fano nanoantennas

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Rui; Decker, Manuel, E-mail: manuel.decker@anu.edu.au; Staude, Isabelle; Neshev, Dragomir N.; Kivshar, Yuri S. [Nonlinear Physics Centre and Centre for Ultrahigh Bandwidth Devices for Optical Systems (CUDOS), Research School of Physics and Engineering, The Australian National University, Canberra ACT 0200 (Australia)

    2014-08-04

    We introduce the concept of a bidirectional, compact single-element Fano nanoantenna that allows for directional coupling of light in opposite directions of a high-index dielectric waveguide for two different operation wavelengths. We utilize a Fano resonance to tailor the radiation phases of a gold nanodisk and a nanoslit that is inscribed into the nanodisk to realize bidirectional scattering. We show that this Fano nanoantenna operates as a bidirectional waveguide coupler at telecommunication wavelengths and, thus, is ideally suitable for integrated wavelength-selective light demultiplexing.

  1. Role of endoscopy in evaluating upper gastrointestinal tract lesions in rural population

    Directory of Open Access Journals (Sweden)

    Sharanabasavaraj Javali

    2015-01-01

    Full Text Available Background and Objectives: Before the advent of endoscopy direct access to the lesion for the confirmation of the diagnosis was difficult, this posed difficulty in contemplating adequate and appropriate surgery. Endoscopy as a diagnostic and therapeutic tool has grown in recent years. Upper gastrointestinal (GI endoscopy is one of the most fascinating branch which serves not only as a means of resolving or amplifying the diagnosis made clinically or by X-ray, but also a primary diagnostic procedure for conditions not otherwise diagnosable on unoperated case. Fiber optic upper GI endoscopy has already become firmly established as a reliable, quick and inexpensive tool. This study was done to detect the upper gastrointestinal lesions in rural population of Kolar District, the distribution pattern of various upper GI lesions in patients presenting with upper GI symptoms and to follow the endoscopic diagnosis for medical and surgical management. Materials and Methods: The study group includes patients reporting to outpatient department and also the inpatients in wards of General Surgery and other departments, who have upper GI symptoms, were advised endoscopy at R. L. JALAPPA Hospital and Research Centre, Kolar, from a period of December 2011 to August 2013. Results: Of the 600 cases, 370 were males, and 230 were females. Disease incidence was highest in 51-70 years age group, that is, 21.6%. Pain abdomen was the most common symptom. Epigastric tenderness was the most common sign among the patients clinically. Reflux esophagitis and diffuse gastritis formed most common cases (307 cases. The incidence of duodenitis - 7.83%, peptic ulcer -3.3%, esophageal varices - 1.5%, the incidence of carcinoma esophagus and carcinoma stomach was approximately same that is, 4.5% and 4.6% respectively. The incidence of esophageal candidiasis was 4.16%. The majority of the patients had a normal study that is, 14.5%. Conclusion: Upper GI lesions were more common in

  2. Helicobacter pylori as an occupational hazard in the endoscopy room

    African Journals Online (AJOL)

    South African Journal of Surgery ... Background: It remains controversial whether or not healthcare workers on upper ... We were unable to confirm that endoscopy was a risk factor for endoscopy teams with regard to contracting H. pylori.

  3. Generalized model of a bidirectional DC-DC converter

    Science.gov (United States)

    Hinov, Nikolay; Arnaudov, Dimitar; Penev, Dimitar

    2017-12-01

    The following paperwork presents models of bidirectional converters. A classic bidirectional converter and a new bidirectional circuit based on a ZCS resonant converter are investigated and compared. The developed models of these converters allow comparison between their characteristics showing their advantages and disadvantages. The models allow precise models of energy storage elements to be implemented as well, which is useful for examination of energy storage systems.

  4. Endoscopy services in KwaZulu-Natal Province, South Africa, are ...

    African Journals Online (AJOL)

    is based on the values and principles of primary healthcare, but major discrepancies ... To audit the GI endoscopy services in KZN and compare these with the current guidelines for ..... Quality assurance of endoscopy units. Best Pract Res Clin ...

  5. The validity of nasal endoscopy in patients with chronic rhinosinusitis

    DEFF Research Database (Denmark)

    Larsen, K. L.; Lange, B.; Darling, P.

    2018-01-01

    Objectives: Nasal endoscopy is a cornerstone in diagnosing sinonasal disease, but different raters might generate different results using the technique. Our study aims to evaluate the agreement between multiple raters to assess the validity of nasal endoscopy. Design/Participants: Three independe...

  6. Impact of Interference in Coexisting Wireless Networks with Applications to Arbitrarily Varying Bidirectional Broadcast Channels

    Directory of Open Access Journals (Sweden)

    Holger Boche

    2012-08-01

    Full Text Available The paradigm shift from an exclusive allocation of frequency bands, one for each system, to a shared use of frequencies comes along with the need of new concepts since interference will be an ubiquitous phenomenon. In this paper, we use the concept of arbitrarily varying channels to model the impact of unknown interference caused by coexisting wireless systems which operate on the same frequencies. Within this framework, capacity can be zero if pre-specified encoders and decoders are used. This necessitates the use of more sophisticated coordination schemes where the choice of encoders and decoders is additionally coordinated based on common randomness. As an application we study the arbitrarily varying bidirectional broadcast channel and derive the capacity regions for different coordination strategies. This problem is motivated by decode-and-forward bidirectional or two-way relaying, where a relay establishes a bidirectional communication between two other nodes while sharing the resources with other coexisting wireless networks.

  7. Canadian Association of Gastroenterology consensus guidelines on safety and quality indicators in endoscopy.

    Science.gov (United States)

    Armstrong, David; Barkun, Alan; Bridges, Ron; Carter, Rose; de Gara, Chris; Dube, Catherine; Enns, Robert; Hollingworth, Roger; Macintosh, Donald; Borgaonkar, Mark; Forget, Sylviane; Leontiadis, Grigorios; Meddings, Jonathan; Cotton, Peter; Kuipers, Ernst J

    2012-01-01

    Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality, highlight the need for clearly defined, evidence-based processes to support quality improvement in endoscopy. To identify processes and indicators of quality and safety relevant to high-quality endoscopy service delivery. A multidisciplinary group of 35 voting participants developed recommendation statements and performance indicators. Systematic literature searches generated 50 initial statements that were revised iteratively following a modified Delphi approach using a web-based evaluation and voting tool. Statement development and evidence evaluation followed the AGREE (Appraisal of Guidelines, REsearch and Evaluation) and GRADE (Grading of Recommendations, Assessment, Development and Evaluation) guidelines. At the consensus conference, participants voted anonymously on all statements using a 6-point scale. Subsequent web-based voting evaluated recommendations for specific, individual quality indicators, safety indicators and mandatory endoscopy reporting fields. Consensus was defined a priori as agreement by 80% of participants. Consensus was reached on 23 recommendation statements addressing the following: ethics (statement 1: agreement 100%), facility standards and policies (statements 2 to 9: 90% to 100%), quality assurance (statements 10 to 13: 94% to 100%), training, education, competency and privileges (statements 14 to 19: 97% to 100%), endoscopy reporting standards (statements 20 and 21: 97% to 100%) and patient perceptions (statements 22 and 23: 100%). Additionally, 18 quality indicators (agreement 83% to 100%), 20 safety indicators (agreement 77% to 100%) and 23 recommended endoscopy-reporting elements (agreement 91% to 100%) were identified. The consensus process identified a clear need for high-quality clinical and outcomes research to support quality improvement in the delivery of endoscopy services. The

  8. Non-small-bowel abnormalities identified during small bowel capsule endoscopy

    NARCIS (Netherlands)

    Hoedemakers, Reinier; Westerhof, Jessie; Weersma, Rinse K.; Koornstra, Jan J.

    2014-01-01

    AIM: To investigate the incidence of non-small-bowel abnormalities in patients referred for small bowel capsule endoscopy, this single center study was performed. METHODS: Small bowel capsule endoscopy is an accepted technique to investigate obscure gastrointestinal bleeding. This is defined as

  9. CT virtual endoscopy: a study of the capability to display the structures and abnormalities in nasal cavity

    International Nuclear Information System (INIS)

    Han Ping; Brambs, H.J.; Sokiranski, R.

    1999-01-01

    Objective: To evaluate display ability of virtual endoscopy and its clinical application in comparison with fiberoptic nasal endoscopy. Methods: 11 patients (22 nasal cavities) were examined by virtual endoscopy after axial spiral CT scanning was performed. Virtual endoscopy was performed by Explorer software package in a computer workstation. 9 patients (18 nasal cavities) underwent fiberoptic endoscopy. Results: Virtual endoscopy could clearly demonstrate the anatomical structures in nasal cavity, septal deviation, nasal meatus narrowing and obstruction, turbinate hyperplasia, and pathological masses larger than 3 mm in diameter. However, 'false adhesions' may appear in virtual endoscopy. The main limitation of virtual endoscopy was inability to evaluate mucosa and lack of histological diagnosis. Conclusions: Virtual endoscopy is a new, non-invasive method for demonstrating anatomical structures and diseases in nasal cavity. Its display ability is comparable with fiberoptic nasal endoscopy and is a supplement to fiberoptic nasal endoscopy

  10. Evaluation of the adverse effects of subcutaneous carprofen over six days in healthy cats.

    Science.gov (United States)

    Steagall, P V M; Moutinho, F Q; Mantovani, F B; Passarelli, D; Thomassian, A

    2009-02-01

    This study evaluated the adverse effects of carprofen in seven healthy cats. Values for CBC, biochemical profiles and platelet aggregation were measured before and at seven days after SID treatment with subcutaneous carprofen: 4 mg/kg (day 1), 2mg/kg (day 2 and 3) and 1mg/kg (day 4 and 6) (CG) or 0.35 ml of saline (SG) for six days in a randomized, blinded, cross-over study with a four-week washout period. No treatment was given on day 5. Endoscopy of the GI tract was performed pre-treatment and on day 7 post-treatment. There were no significant changes in hematological profiles, biochemical profiles and endoscopy grading scores within nor between groups, except for lower albumin values at baseline than on day 7 (CG), and globulin and ALP values were higher at baseline than on day 7 in CG and SG. SC administration of carprofen over six days did not cause any adverse effects on gastrointestinal, hematological, or serum biochemical variables.

  11. Improving the timeliness of procedures in a pediatric endoscopy suite.

    Science.gov (United States)

    Tomer, Gitit; Choi, Steven; Montalvo, Andrea; Sutton, Sheila; Thompson, John; Rivas, Yolanda

    2014-02-01

    Pediatric endoscopic procedures are essential in the evaluation and treatment of gastrointestinal diseases in children. Although pediatric endoscopists are greatly interested in increasing efficiency and through-put in pediatric endoscopy units, there is scarcely any literature on this critical process. The goal of this study was to improve the timeliness of pediatric endoscopy procedures at Children's Hospital at Montefiore. In June 2010, a pediatric endoscopy quality improvement initiative was formed at Children's Hospital at Montefiore. We identified patient-, equipment-, and physician-related causes for case delays. Pareto charts, cause and effect diagrams, process flow mapping, and statistical process control charts were used for analysis. From June 2010 to December 2012, we were able to significantly decrease the first case endoscopy delay from an average of 17 to 10 minutes (P < .001), second case delay from 39 to 25 minutes (P = .01), third case delay from 61 to 45 minutes (P = .05), and fourth case delay from 79 to 51 minutes (P = .05). Total delay time decreased from 196 to 131 minutes, resulting in a reduction of 65 minutes (P = .02). From June 2010 to August 2011 (preintervention period), an average of 36% of first endoscopy cases started within 5 minutes, 51% within 10 minutes, and 61% within 15 minutes of the scheduled time. From September 2011 to December 2012 (postintervention period), the percentage of cases starting within 5 minutes, 10 minutes, and 15 minutes increased to 47% (P = .07), 61% (P = .04), and 79% (P = .01), respectively. Applying quality improvement methods and tools helped improve pediatric endoscopy timeliness and significantly decreased total delays.

  12. Intergenerational Transmission in a Bidirectional Context

    Directory of Open Access Journals (Sweden)

    Jan De Mol

    2013-07-01

    Full Text Available Traditional approaches to the study of parent-child relationships view intergenerational transmission as a top-down phenomenon in which parents transfer their values, beliefs, and practices to their children. Furthermore, the focus of these unidirectional approaches regarding children's internalisation processes is on continuity or the transmission of similar values, beliefs, and practices from parents to children. Analogous unidirectional perspectives have also influenced the domain of family therapy. In this paper a cognitive-bidirectional and dialectical model of dynamics in parent-child relationships is discussed in which the focus is on continual creation of novel meanings and not just reproduction of old ones in the bidirectional transmission processes between parents and children. Parents and children are addressed as full and equally agents in their interdependent relationship, while these relational dynamics are embedded within culture. This cultural context complicates bidirectional transmission influences in the parent-child relationship as both parents and children are influenced by many other contexts. Further, current research in the domain of parent-child relationships and current concepts of intergenerational transmission in family therapy are reviewed from a bidirectional cognitive-dialectical perspective.

  13. Review of musculoskeletal injuries and prevention in the endoscopy practitioner.

    Science.gov (United States)

    Harvin, Glenn

    2014-08-01

    Practitioners of endoscopy often experience musculoskeletal pain and injury (most often in the back, neck, shoulders, hands, wrists, and thumbs) that are associated with the minute and repetitive strain that is placed on these areas during endoscopic procedures. This review of the current documentation of endoscopy-related pain and injuries among practitioners finds that such problems are widespread and specific in kind as well as strongly correlated with high procedure volume and procedure duration. Research on the nature and impact of cumulative trauma and overuse syndromes in other professions such as dentistry, pianists, production labor, and athletics is brought to bear on the work of the endoscopist. A more thorough understanding of the nature and prevalence of work-related pain and injury sustained by endoscopists should inform further development of ergonomic practices and equipment design. This article reviews current recommendations for ergonomic design in the endoscopy procedure space and finds that reported compliance with those recommendations is quite low. Strategies for the management of the risk of musculoskeletal injuries related to the practice of endoscopy include compliance with currently recommended ergonomic practices, education of trainees in ergonomic technique when practicing endoscopy, and research toward the modification and development of more ergonomic endoscopes and procedure spaces.

  14. Chromoendoscopy and magnification endoscopy in Barrett's esophagus.

    Science.gov (United States)

    Connor, Michael J; Sharma, Prateek

    2003-04-01

    Chromoendoscopy and magnification endoscopy appear to be a valuable adjuncts for the detection and classification of BE. These techniques may also prove to be useful aids in surveillance protocols for identifying dysplastic epithelium or early cancer within a segment of BE. Ideally, the use of these techniques would enable the endoscopist to rule in or out the presence of IM and of dysplastic or cancerous epithelium by obtaining only a minimal number of targeted biopsy specimens, or potentially performing no biopsies at all. This could transform upper endoscopy into a much more effective screening and surveillance tool for BE. Several problems currently exist for the use of chromoendoscopy for BE. Results of studies reporting the accuracy of chromoendoscopy remain mixed,and are likely explained by the wide range of techniques and materials used in the investigations. Staining adds several steps, and likely several minutes, to an upper endoscopy. Staining within the esophagus is often patchy and uneven. In addition, poor spraying technique exaggerates the irregular uptake by the mucosa. There is a high false-positive rate when staining gastric-type epithelium and denuded epithelium. Areas of dysplasia or cancer may take up stain in an irregular manner, or may not stain at all. Chromoendoscopy is a relatively new technique in the management of BE and depends on the skill and experience of the endoscopist. Magnification, however, only allows the endoscopist to observe small areas of mucosa at a time, increasing the overall complexity and length of the procedure. The learning curve for this procedure is relatively short, however, and endoscopists can usually become proficient in the technique quickly. Currently, the greatest body of literature exists concerning the use of methylene blue for diagnosing BE. At the present time, chromoendoscopy and magnification endoscopy appear to be most beneficial in detecting IM in short segments of esophageal columnar

  15. Bidirectional optical scattering facility

    Data.gov (United States)

    Federal Laboratory Consortium — Goniometric optical scatter instrument (GOSI)The bidirectional reflectance distribution function (BRDF) quantifies the angular distribution of light scattered from a...

  16. The European Society of Gastrointestinal Endoscopy Quality Improvement Initiative: developing performance measures.

    Science.gov (United States)

    Rutter, Matthew D; Senore, Carlo; Bisschops, Raf; Domagk, Dirk; Valori, Roland; Kaminski, Michal F; Spada, Cristiano; Bretthauer, Michael; Bennett, Cathy; Bellisario, Cristina; Minozzi, Silvia; Hassan, Cesare; Rees, Colin; Dinis-Ribeiro, Mário; Hucl, Tomas; Ponchon, Thierry; Aabakken, Lars; Fockens, Paul

    2016-02-01

    The European Society of Gastrointestinal Endoscopy (ESGE) and United European Gastroenterology (UEG) have a vision to create a thriving community of endoscopy services across Europe, collaborating with each other to provide high quality, safe, accurate, patient-centered and accessible endoscopic care. Whilst the boundaries of what can be achieved by advanced endoscopy are continually expanding, we believe that one of the most fundamental steps to achieving our goal is to raise the quality of everyday endoscopy. The development of robust, consensus- and evidence-based key performance measures is the first step in this vision. ESGE and UEG have identified quality of endoscopy as a major priority. This paper explains the rationale behind the ESGE Quality Improvement Initiative and describes the processes that were followed. We recommend that all units develop mechanisms for audit and feedback of endoscopist and service performance using the ESGE performance measures that will be published in future issues of this journal over the next year. We urge all endoscopists and endoscopy services to prioritize quality and to ensure that these performance measures are implemented and monitored at a local level, so that we can provide the highest possible care for our patients.

  17. Usefulness of post-mortem ophthalmological endoscopy during forensic autopsy: a case report.

    Science.gov (United States)

    Tsujinaka, Masatake; Akaza, Kayoko; Nagai, Atsushi; Nakamura, Isao; Bunai, Yasuo

    2005-01-01

    Post-mortem intraocular findings in two autopsy cases with traumatic intracranial haemorrhage were obtained using an ophthalmological endoscope. The endoscopy results clearly revealed the presence of intraocular haemorrhages and papilledema caused by intracranial haemorrhage. Post-mortem ophthalmological endoscopy offers several benefits. First, post-mortem intraocular findings can be directly observed in corpses with post-mortem clouding of the cornea. Secondly, the endoscopy only requires a 0.9 mm incision in the sclera and does not require the removal of the eye from the corpse, a procedure that should be avoided for ethical and cosmetic reasons. Thus, post-mortem opthalmological endoscopy is a useful method for obtaining intraocular findings in autopsies.

  18. Upper Gastro-Intestinal Endoscopy in Port Harcourt, Nigeria: An Audit

    African Journals Online (AJOL)

    Background: Accurate diagnosis of disease conditions using laboratory, imaging or endoscopic investigation is essential for appropriate treatment. There is paucity of data on upper GI endoscopy in Port-Harcourt. This audit of our early experience is intended to provide data on the pattern of endoscopy findings which is ...

  19. Virtual MRI endoscopy of the intracranial cerebrospinal fluid spaces

    International Nuclear Information System (INIS)

    Shigematsu, Y.; Korogi, Y.; Hirai, T.; Okuda, T.; Ikushima, I.; Sugahara, T.; Liang, L.; Ge, Y.; Takahashi, M.

    1998-01-01

    We used constructive interference in steady state (CISS) 3D Fourier transform (3DFT) MRI data sets to obtain three-dimensional (3D) virtual MRI endoscopic views of the intracranial cerebrospinal fluid (CSF) spaces, processing them with a commercially available perspective endoscopic algorithm. We investigated the potential of the intracranial virtual MRI endoscopy applied to visualisation of the pathology in 13 patients with surgically confirmed trigeminal neuralgia (3), hemifacial spasm (3), acoustic neuroma (3), suprasellar germinoma (1), Langerhans cell histiocytosis (1), lateral ventricle nodules (1) and pituitary dwarfism (1). All images were acquired using a 1.5-T imager employing a circular polarised head coil. The CISS-3DFT data sets were transferred to a workstation for processing with the perspective endoscopic algorithm. Postprocessing for virtual MRI endoscopy was possible for all data sets. The lesions in 12 patients, and their complex anatomical relationships with the surrounding structures, were well seen on the 3D images. A small acoustic neuroma in the internal auditory meatus was not seen using virtual endoscopy. Although virtual MRI endoscopy has limitations, it provides 3D images which cannot be acquired using any other procedure. (orig.)

  20. Virtual MRI endoscopy of the intracranial cerebrospinal fluid spaces

    Energy Technology Data Exchange (ETDEWEB)

    Shigematsu, Y.; Korogi, Y.; Hirai, T. [Kumamoto Univ. (Japan). Dept. of Radiology; Okuda, T.; Ikushima, I.; Sugahara, T.; Liang, L.; Ge, Y.; Takahashi, M.

    1998-10-01

    We used constructive interference in steady state (CISS) 3D Fourier transform (3DFT) MRI data sets to obtain three-dimensional (3D) virtual MRI endoscopic views of the intracranial cerebrospinal fluid (CSF) spaces, processing them with a commercially available perspective endoscopic algorithm. We investigated the potential of the intracranial virtual MRI endoscopy applied to visualisation of the pathology in 13 patients with surgically confirmed trigeminal neuralgia (3), hemifacial spasm (3), acoustic neuroma (3), suprasellar germinoma (1), Langerhans cell histiocytosis (1), lateral ventricle nodules (1) and pituitary dwarfism (1). All images were acquired using a 1.5-T imager employing a circular polarised head coil. The CISS-3DFT data sets were transferred to a workstation for processing with the perspective endoscopic algorithm. Postprocessing for virtual MRI endoscopy was possible for all data sets. The lesions in 12 patients, and their complex anatomical relationships with the surrounding structures, were well seen on the 3D images. A small acoustic neuroma in the internal auditory meatus was not seen using virtual endoscopy. Although virtual MRI endoscopy has limitations, it provides 3D images which cannot be acquired using any other procedure. (orig.) With 6 figs., 16 refs.

  1. Impact of educational intervention on the inter-rater agreement of nasal endoscopy interpretation

    Science.gov (United States)

    Colley, Patrick; Mace, Jess C.; Schaberg, Madeleine R.; Smith, Timothy L.; Tabaee, Abtin

    2015-01-01

    OBJECTIVE Nasal endoscopy is integral to the evaluation of sinonasal disorders. However, prior studies have shown significant variability in the inter-rater agreement of nasal endoscopy interpretation amongst practicing rhinologists. The objective of the current study is to evaluate the inter-rater agreement of nasal endoscopy amongst otolaryngology residents from a single training program at baseline and following an educational intervention. METHODS 11 otolaryngology residents completed nasal endoscopy grading forms for 8 digitally recorded nasal endoscopic examinations. An instructional lecture reviewing nasal endoscopy interpretation was subsequently provided. The residents then completed grading forms for 8 different nasal endoscopic examinations. Inter-rate agreement amongst residents for the pre- and post-lecture videos was calculated using the unweighted Fleiss’ kappa statistic (Kf) and intra-class correlation agreement (ICC). RESULTS Inter-rater agreement improved from a baseline level of fair (Kf range 0.268–0.383) to a post-educational level of moderate (Kf range 0.401–0.547) for nasal endoscopy findings of middle meatus mucosa, middle turbinate mucosa, middle meatus discharge, sphenoethmoid recess mucosa, sphenoethmoid recess discharge and atypical lesions (ICC, pendoscopy interpretation amongst otolaryngology residents. The inter-rater agreement for the majority of the characteristics that were evaluated improved after educational intervention. Further study is needed to improve nasal endoscopy interpretation. PMID:25781864

  2. A bidirectional Optimality Theoretic analysis of multiple negative ...

    African Journals Online (AJOL)

    IT

    6 All examples in this paper are colloquial Afrikaans unless otherwise ...... and bidirectional optimisation over these form-meaning pairs results in the selection of one or ..... Imperfective and perfective habituals in Polish: A bi-directional.

  3. Same- and Other-Sex Popularity and Preference during Early Adolescence

    Science.gov (United States)

    Bowker, Julie C.; Adams, Ryan E.; Bowker, Matthew H.; Fisher, Carrie; Spencer, Sarah V.

    2016-01-01

    This study examined the longitudinal and bidirectional relations between same-sex (SS) and other-sex (OS) popularity and preference across one school year. Participants were 271 sixth-grade students who completed peer nomination measures at three time points in their schools. Tests of cross-lagged autoregressive models indicated that SS popularity…

  4. Sedation and Monitoring in the Pediatric Patient during Gastrointestinal Endoscopy.

    Science.gov (United States)

    Chung, Hyun Kee; Lightdale, Jenifer R

    2016-07-01

    Sedation is a fundamental component of pediatric gastrointestinal procedures. The 2 main types of sedation for pediatric endoscopy remain general anesthesia and procedural sedation. Although anesthesiologist-administered sedation protocols are more common, there is no ideal regimen for endoscopy in children. This article discusses specific levels of sedation for endoscopy as well as various regimens that can be used to achieve each. Risks and considerations that may be specific to performing gastrointestinal procedures in children are reviewed. Finally, potential future directions for sedation and monitoring that may change the practice of pediatric gastroenterology and ultimately patient outcomes are examined. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Daily Stress and Emotional Well-Being among Asian American Adolescents: Same-Day, Lagged, and Chronic Associations

    Science.gov (United States)

    Kiang, Lisa; Buchanan, Christy M.

    2014-01-01

    Daily-diary data from 180 Asian American 9th-10th graders (58% female, 75% second generation; "M" age = 14.97 years) were used to investigate how family, school, and peer stress are each associated with same-day and next-day (lagged) well-being, and vice versa. Hierarchical linear modeling provided support for reciprocal links when…

  6. Endoscopy and sedation: an inseparable binomial for the gastroenterologist.

    Science.gov (United States)

    Crespo, Javier; Terán, Álvaro

    2018-04-01

    The development of endoscopy and its increasing demand among the population have led to a growing need for propofol-based sedation techniques. Benefit is indisputable for both patients and endoscopists, but some aspects require considering the "who" and "how" of sedation as related to safety and health care costs. Propofol is first-choice in endoscopy for the European Society of Gastrointestinal Endoscopy because of its fast onset of action and short half-life, and many reports exist on its safety when used by gastroenterologists rather than anesthesiologists. In this issue of REED several originals support the efficiency and safety of propofol even for complex, high-risk, or protracted procedures such as endoscopic retrograde cholangiopancreatography (ERCP) and enteroscopy. Propofol may be safely and effectively administered by a team with specific skills acquired through education and using a specific procedure. However, difficulties arise in real-world clinical practice that preclude such training, which in Spain should be included in the MIR (médico interno residente) specialization program curriculum. The Comisión Nacional de Digestivo (Spanish National Commission on Digestive Diseases), sensitive to this training gap, has included in their latest version of the MIR program (under assessment) four additional competences, with number 145 (training in deep sedation) being most relevant here. In addition, the Spanish Society of Gastrointestinal Endoscopy (SEED) has invested significant efforts in sedation training, with over 50 courses on sedation for endoscopists and nurses. Continuing education and training in this field (for instance, refresher courses on advanced cardiopulmonary resuscitation) should be a goal for all endoscopy units. Because of the diversity found among hospitals, with single or multiple endoscopy rooms, efforts should be made to persuade those in charge of gastroenterology and anesthesiology departments to establish the necessary care

  7. Upper gastrointestinal endoscopy in children: The Lagos University Teaching Hospital experience

    Directory of Open Access Journals (Sweden)

    Oluwafunmilayo Funke Adeniyi

    2016-12-01

    Full Text Available Background. Paediatric endoscopy is now standard care in the developed world for the management of gastrointestinal (GI disorders. However, in developing countries endoscopy remains an underutilised tool. Objective. To determine the indications and the spectrum of endoscopic findings in children seen at the Lagos University Teaching Hospital, Nigeria. Methods. The indications for upper GI endoscopy and endoscopic findings in children ≤16 years old, referred for the procedure from June 2013 to June 2016, were documented. The endoscopic yield in these children was also determined. Results. In total 71 children were referred for upper GI endoscopy during the study period. There were 35 boys and 36 girls aged 3 months to 16 years. The indications for upper endoscopy were recurrent abdominal pain in 37 (52.1%, upper GI bleeding in 17 (23.9%, recurrent vomiting in 7 (9.9%, dyspepsia in 5 (7.0, heartburn in 2 (2.8%, dysphagia in 1 (1.4, portal hypertension in 1 (1.4 and ingestion of corrosives in 1 (1.4% of the subjects. Endoscopic findings were as follows: gastritis 19 (26.8%, hiatus hernia in 13 (18.3%, gastric erosions in 12 (16.9%, oesophageal varices 6 (8.4%, duodenitis in 4 (5.6%, gastric ulcer in 3 (4.2%, gastric polyp in 2 (2.8%. The overall endoscopic yield was 60.2%. Conclusion. There is a need to increase the awareness of the role of paediatric endoscopy in the diagnosis and treatment of GI disorders in developing countries. Recurrent abdominal pain still remains a relevant indication for the procedure. The need to develop training programmes for paediatric endoscopy and paediatric gastroenterology in general in developing countries cannot be overemphasised.

  8. Non-technical skills and gastrointestinal endoscopy: a review of the literature.

    Science.gov (United States)

    Hitchins, Charlotte R; Metzner, Magdalena; Edworthy, Judy; Ward, Catherine

    2018-04-01

    Non-technical skills (NTS) have gained increasing recognition in recent years for their role in safe, effective team performance in healthcare. Gastrointestinal endoscopy is a procedure-based specialty with rapidly advancing technology, significant operational pressures and rapidly changing 'teams of experts'. However, to date there has been little focus on the effect of NTS in this field. This review aims to examine the existing literature on NTS in gastrointestinal endoscopy and identify areas for further research. A systematic search of MEDLINE, Embase, Cochrane Library, PsychINFO, CINAHL Plus and PubMed databases was performed using search terms Non-Technical Skills, Team Performance or Team Skills, and Endoscopy, Colonoscopy, OGD, Gastroscopy, Endoscopic Retrograde Cholangio-Pancreatography or Endoscopic Ultrasound. Eighteen relevant publications were found. NTS are deemed an essential component of practice, but so far there is little evidence of their integration into training or competency assessment. Those studies examining the effects of NTS and team training in endoscopy are small and have variable outcome measures with limited evidence of improvement in skills or clinical outcomes. NTS assessment in endoscopy is in its early phases with a few tools in development. The current literature on NTS in gastrointestinal endoscopy is limited. NTS, however, are deemed an essential component of practice, with potential positive effects on team performance and clinical outcomes. A validated reliable tool would enable evaluation of training and investigation into the effects of NTS on outcomes. There is a clear need for further research in this field.

  9. Risk factors for nasal bleeding in patients undergoing transnasal gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Mitsuyo Mieda

    2018-05-01

    Full Text Available Transnasal endoscopy is widely used in screening for upper gastrointestinal lesions because of less associated pain. Nasal bleeding is the most severe adverse effect, but specific risk factors have not been identified. The aim of this study is to identify risk factors for nasal bleeding during transnasal endoscopy. Nasal bleeding occurred in 160/3035 (5.3% of patients undergoing transnasal endoscopy as part of health checkups. Patient data were retrospectively evaluated including anthropometric, medical, and life-style parameters with multiple logistic regression analysis. Multiple logistic regression revealed that nasal bleeding was significantly associated with age in decades [odds ratio/10 years 0.78, 95% confidence interval (CI 0.63–0.97, p = 0.027], female gender (2.15, 95% CI 1.48–3.12, p < 0.001, a history of previous upper gastrointestinal endoscopy (0.55, 95% CI 0.36–0.82, p = 0.004, and chronic/allergic rhinitis (0.60, 95% CI 0.36–0.98, p = 0.043. Other factors including the use of antiplatelet and/or anticoagulant drugs were not significantly associated with nasal bleeding. Female and young patients are significantly associated with an increased risk of bleeding from transnasal endoscopy, but antiplatelet and/or anticoagulant medications and a history of chronic/allergic rhinitis may not be associated. Keywords: Transnasal endoscopy, Nasal bleeding, Risk factors

  10. Bidirectional neural interface: Closed-loop feedback control for hybrid neural systems.

    Science.gov (United States)

    Chou, Zane; Lim, Jeffrey; Brown, Sophie; Keller, Melissa; Bugbee, Joseph; Broccard, Frédéric D; Khraiche, Massoud L; Silva, Gabriel A; Cauwenberghs, Gert

    2015-01-01

    Closed-loop neural prostheses enable bidirectional communication between the biological and artificial components of a hybrid system. However, a major challenge in this field is the limited understanding of how these components, the two separate neural networks, interact with each other. In this paper, we propose an in vitro model of a closed-loop system that allows for easy experimental testing and modification of both biological and artificial network parameters. The interface closes the system loop in real time by stimulating each network based on recorded activity of the other network, within preset parameters. As a proof of concept we demonstrate that the bidirectional interface is able to establish and control network properties, such as synchrony, in a hybrid system of two neural networks more significantly more effectively than the same system without the interface or with unidirectional alternatives. This success holds promise for the application of closed-loop systems in neural prostheses, brain-machine interfaces, and drug testing.

  11. [The role of endoscopy in gastroenteropancreatic neuroendocrine tumors].

    Science.gov (United States)

    Magno, L; Sivero, L; Napolitano, V; Ruggiero, S; Fontanarosa, G; Massa, S

    2010-01-01

    Versione italiana Riassunto: Il ruolo dell'endoscopia nei tumori neuroendocrini gastroenteropancreatici. L. Magno, L. Sivero, V. Napolitano, S. Ruggiero, G. Fontanarosa, S. Massa I tumori neuroendocrini (NET) gastro-entero-pancreatici (GEP) sono neoplasie rare che originano dalle cellule neuroendocrine del tubo digerente e del pancreas. L'endoscopia digestiva e l'ecoendoscopia rivestono un ruolo importante nella diagnosi, stadiazione e sorveglianza dei pazienti con NET. Inoltre, in casi selezionati, le tecniche endoscopiche operative consentono il trattamento di queste neoplasie in fase precoce. English version Summary: The role of endoscopy in gastroenteropancreatic neuroendocrine tumors. L. Magno, L. Sivero, V. Napolitano, S. Ruggiero, G. Fontanarosa, S. Massa Gastroenteropancreatic (GEP) neuroendocrine tumors (NET) are rare neoplasia arisen from neuroendocrine cells present in the gut mucosa and pancreas. Digestive endoscopy and endoscopic ultrasonography play a relevant role in NET diagnosis, stadiation and surveillance. Moreover, in selected patients, surgical endoscopy allows the tratment of these cancers at an early stage.

  12. The application value of capsule endoscopy in diagnosing small intestinal carcinoma

    Directory of Open Access Journals (Sweden)

    Xiaohuan Li

    2018-01-01

    Conclusion: Capsule endoscopy demonstrated a high diagnostic value for various small bowel diseases, including both tumor and inflammatory lesions. Given its simplicity, safety, and reliability, capsule endoscopy was an important examination tool for the diagnosis of small bowel diseases.

  13. A novel method for sampling the suspended sediment load in the tidal environment using bi-directional time-integrated mass-flux sediment (TIMS) samplers

    Science.gov (United States)

    Elliott, Emily A.; Monbureau, Elaine; Walters, Glenn W.; Elliott, Mark A.; McKee, Brent A.; Rodriguez, Antonio B.

    2017-12-01

    Identifying the source and abundance of sediment transported within tidal creeks is essential for studying the connectivity between coastal watersheds and estuaries. The fine-grained suspended sediment load (SSL) makes up a substantial portion of the total sediment load carried within an estuarine system and efficient sampling of the SSL is critical to our understanding of nutrient and contaminant transport, anthropogenic influence, and the effects of climate. Unfortunately, traditional methods of sampling the SSL, including instantaneous measurements and automatic samplers, can be labor intensive, expensive and often yield insufficient mass for comprehensive geochemical analysis. In estuaries this issue is even more pronounced due to bi-directional tidal flow. This study tests the efficacy of a time-integrated mass sediment sampler (TIMS) design, originally developed for uni-directional flow within the fluvial environment, modified in this work for implementation the tidal environment under bi-directional flow conditions. Our new TIMS design utilizes an 'L' shaped outflow tube to prevent backflow, and when deployed in mirrored pairs, each sampler collects sediment uniquely in one direction of tidal flow. Laboratory flume experiments using dye and particle image velocimetry (PIV) were used to characterize the flow within the sampler, specifically, to quantify the settling velocities and identify stagnation points. Further laboratory tests of sediment indicate that bidirectional TIMS capture up to 96% of incoming SSL across a range of flow velocities (0.3-0.6 m s-1). The modified TIMS design was tested in the field at two distinct sampling locations within the tidal zone. Single-time point suspended sediment samples were collected at high and low tide and compared to time-integrated suspended sediment samples collected by the bi-directional TIMS over the same four-day period. Particle-size composition from the bi-directional TIMS were representative of the array of

  14. Monitoring of Intracranial Pressure During Intracranial Endoscopy

    Directory of Open Access Journals (Sweden)

    Rajeev Kumar

    2013-08-01

    Full Text Available Background: Intracranial endoscopy is a minimum invasive procedure, which reduces trauma to the brain, is cost-effective, and carries a shortened hospital stay with an improved postoperative outcome. Objective: To monitor intracranial pressure changes during intracranial endoscopy among children and adults under general anesthesia/sedation, and to compare the intracranial pressure changes between children and adults receiving general anesthesia and among adults receiving general anesthesia and sedation. Methods: The present cross-sectional study was conducted in one of the tertiary care hospitals of Lucknow. This was carried out in the department of neurosurgery from January 2008 to December 2008. Patients who were not fit for general anesthesia received local anesthesia under sedation. Patients participating in the study were divided into three groups. Intracranial pressure was recorded at specific intervals. Parametric data were subjected to statistical analysis using a student\\s t test. Result: A total of 70 patients were undergoing intracranial endoscopy under general anesthesia during the study period. In both groups A and B, intracranial pressure increases the maximum during inflation of the balloon. In group C, all the variations in ICP were found to be statistically significant. In the comparison of intracranial pressure changes between groups A and B, no significant difference was found. All correlations in the comparison of groups B and C were found to be statistically significant (p< 0.001. Conclusion: There is a need for continuous intraoperative monitoring of ICP intracranial endoscopy, because ICP increases in various stages of the procedure, which can be detrimental to the perfusion of the brain. [Arch Clin Exp Surg 2013; 2(4.000: 240-245

  15. Image Captioning with Deep Bidirectional LSTMs

    OpenAIRE

    Wang, Cheng; Yang, Haojin; Bartz, Christian; Meinel, Christoph

    2016-01-01

    This work presents an end-to-end trainable deep bidirectional LSTM (Long-Short Term Memory) model for image captioning. Our model builds on a deep convolutional neural network (CNN) and two separate LSTM networks. It is capable of learning long term visual-language interactions by making use of history and future context information at high level semantic space. Two novel deep bidirectional variant models, in which we increase the depth of nonlinearity transition in different way, are propose...

  16. A primary intestinal lymphangiectasia patient diagnosed by capsule endoscopy and confirmed at surgery: a case report.

    Science.gov (United States)

    Fang, You-Hong; Zhang, Bing-Ling; Wu, Jia-Guo; Chen, Chun-Xiao

    2007-04-21

    Intestinal lymphangiectasia (IL) is a rare disease characterized by dilated lymphatic vessles in the intestinal wall and small bowel mesentery which induce loss of protein and lymphocytes into bowel lumen. Because it most often occurs in the intestine and cannot be detected by upper gastroendoscopy or colonoscopy, and the value of common image examinations such as X-ray and computerized tomography (CT) are limited, the diagnosis of IL is difficult, usually needing the help of surgery. Capsule endoscopy is useful in diagnosing intestinal diseases, such as IL. We here report a case of IL in a female patient who was admitted for the complaint of recurrent edema accompanied with diarrhea and abdominal pain over the last twenty years, and aggravated ten days ago. She was diagnosed by M2A capsule endoscopy as a primary IL and confirmed by surgical and pathological examination.

  17. Upper gastrointestinal endoscopy at the korle bu teaching hospital, accra, ghana.

    Science.gov (United States)

    Aduful, Hk; Naaeder, Sb; Darko, R; Baako, Bn; Clegg-Lamptey, Jna; Nkrumah, Kn; Adu-Aryee, Na; Kyere, M

    2007-03-01

    To study the indications for endoscopy, the endoscopic diagnosis and other lessons learnt. A retrospective and prospective audit of all upper gastrointestinal endoscopies performed in the Endoscopy Unit of the Korle-Bu Teaching Hospital from January 1995 to December 2002 was performed. A total of 6977 patients, 3777 males and 3200 females with age range 1 year 8 months to 93 years were endoscoped. The mean age of males was 43.5 +/- 0.5 and females 43.7 +/- 0.6 years. Epigastric pain (42.5%), dyspepsia (32.8%) and haematemesis and melaena (14.2%) were the commonest reasons for endoscopy. Chronic duodenal ulcer (19.6%), acute gastritis (12.7%), duodenitis (10.2%), oesophagitis (7.5%) were the commonest diagnoses. Normal endoscopy was reported in 41.1% patients, and was higher in the younger age group compared to the older (R = 0.973, P<0.001). Nine hundred and ninety (14.2%) patients were endoscoped for haematemesis and melaena of which chronic duodenal ulcer (32.1%), gastritis/gastric erosions (12.8%), oesophageal varices (9.8%), carcinoma of the stomach (6.4%), and duodenitis (4.2%), were the commonest causes. No lesion was found in 20.6% of these patients. Urease test was positive in 75% of all biopsy specimen and 85% in chronic duodenal ulcer, gastritis and duodenitis. The normal endoscopy rate is high and needs to be reduced in order to help prolong the lives of the endoscopes. Chronic duodenal ulcer is usually associated with H. pylori infection and is the commonest cause of upper gastrointestinal bleeding.

  18. Cerebral gas embolism due to upper gastrointestinal endoscopy.

    Science.gov (United States)

    ter Laan, Mark; Totte, Erik; van Hulst, Rob A; van der Linde, Klaas; van der Kamp, Wim; Pierie, Jean-Pierre E

    2009-07-01

    Cerebral gas embolism as a result of upper gastrointestinal endoscopy is a rare complication and bares a high morbidity. A patient is presented who underwent an upper endoscopy for evaluation of a gastric-mediastinal fistula after subtotal oesophagectomy and gastric tube reconstruction because of oesophageal cancer. During the procedure, cerebral gas emboli developed resulting in an acute left-sided hemiparesis. After hyperbaric oxygen therapy, the patient recovered almost completely. The aetiology and treatment is discussed based on the reviewed literature. Once cerebral gas emboli are recognized, patient outcome can be improved by hyperbaric oxygen therapy.

  19. Deep Learning in Gastrointestinal Endoscopy.

    Science.gov (United States)

    Patel, Vivek; Armstrong, David; Ganguli, Malika; Roopra, Sandeep; Kantipudi, Neha; Albashir, Siwar; Kamath, Markad V

    2016-01-01

    Gastrointestinal (GI) endoscopy is used to inspect the lumen or interior of the GI tract for several purposes, including, (1) making a clinical diagnosis, in real time, based on the visual appearances; (2) taking targeted tissue samples for subsequent histopathological examination; and (3) in some cases, performing therapeutic interventions targeted at specific lesions. GI endoscopy is therefore predicated on the assumption that the operator-the endoscopist-is able to identify and characterize abnormalities or lesions accurately and reproducibly. However, as in other areas of clinical medicine, such as histopathology and radiology, many studies have documented marked interobserver and intraobserver variability in lesion recognition. Thus, there is a clear need and opportunity for techniques or methodologies that will enhance the quality of lesion recognition and diagnosis and improve the outcomes of GI endoscopy. Deep learning models provide a basis to make better clinical decisions in medical image analysis. Biomedical image segmentation, classification, and registration can be improved with deep learning. Recent evidence suggests that the application of deep learning methods to medical image analysis can contribute significantly to computer-aided diagnosis. Deep learning models are usually considered to be more flexible and provide reliable solutions for image analysis problems compared to conventional computer vision models. The use of fast computers offers the possibility of real-time support that is important for endoscopic diagnosis, which has to be made in real time. Advanced graphics processing units and cloud computing have also favored the use of machine learning, and more particularly, deep learning for patient care. This paper reviews the rapidly evolving literature on the feasibility of applying deep learning algorithms to endoscopic imaging.

  20. Small bowel preparations for capsule endoscopy with mannitol and simethicone: a prospective, randomized, clinical trial.

    Science.gov (United States)

    Chen, Hong-bin; Huang, Yue; Chen, Su-yu; Song, Hui-wen; Li, Xiao-lin; Dai, Dong-lin; Xie, Jia-tia; He, Song; Zhao, Yuan-yuan; Huang, Chun; Zhang, Sheng-jun; Yang, Lin-na

    2011-04-01

    There is no consensus concerning small bowel preparation before capsule endoscopy (CE). This study evaluated the effects of 4 regimens on small bowel cleansing and diagnostic yield. Patients were randomly divided into 4 groups. Group A consumed a clear liquid diet after lunch on the day before CE, followed by overnight fasting. Group B took 250 mL 20% mannitol and 1 L 0.9% saline orally at 05:00 hours on the day of the procedure. In group C, the same regimen was taken at 20:00 hours on the day before and at 05:00 hours on the day of CE. In group D, in addition to the group C regimen, 20 mL oral simethicone was taken 30 minutes before CE. Two hundred patients were prospectively enrolled, and 7 were excluded from the final analysis because of incomplete small bowel transit. No significant difference was noted among the 4 groups for small bowel transit time. Bowel preparation in group D was significantly better than for the other regimens for overall cleansing of the proximal small bowel, and showed improved overall cleansing of the distal small bowel when compared with 10-hours overnight fasting. Pathological lesions of the proximal and distal small bowel were, respectively, achieved in 82 and 74 patients, mostly distributed in group D. Small bowel preparation that involves split-dose oral mannitol plus single-dose simethicone for CE can improve mucosal visualization and subsequent diagnostic yield when compared with 10-hours overnight fasting.

  1. Development of a bi-directional standing wave linear piezoelectric actuator with four driving feet.

    Science.gov (United States)

    Liu, Yingxiang; Shi, Shengjun; Li, Chunhong; Chen, Weishan; Wang, Liang; Liu, Junkao

    2018-03-01

    A bi-directional standing wave linear piezoelectric ultrasonic actuator with four driving feet is proposed in this work. Two sandwich type transducers operated in longitudinal-bending hybrid modes are set parallelly. The working mode of the transducer is not simple hybrid vibrations of a longitudinal one and a bending one, but a special coupling vibration mode contained both longitudinal and bending components. Two transducers with the same structure and unsymmetrical boundary conditions are set parallelly to accomplish the bi-directional driving: the first transducer can push the runner forward, while the other one produces the backward driving. In the experiments, two voltages with different amplitudes are applied on the two transducers, respectively: the one with higher voltage serves as the actuator, whereas the other one applied with lower voltage is used to reduce the frictional force. The prototype achieves maximum no-load speed and thrust force of 244 mm/s and 9.8 N. This work gives a new idea for the construction of standing wave piezoelectric ultrasonic actuator with bi-directional driving ability. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Bidirectional Relations Between Dating Violence Victimization and Substance Use in a Diverse Sample of Early Adolescents.

    Science.gov (United States)

    Taylor, Katherine A; Sullivan, Terri N

    2017-09-01

    Substance use and dating violence victimization are common in adolescence and represent significant public health concerns. Although theoretical accounts suggest a bidirectional association between substance use and victimization within dating relationships, this has not been tested during early adolescence. Thus, the current study examined bidirectional associations between physical and psychological dating violence victimization and substance use across 6 months among an ethnically diverse sample of early adolescents. Sex was also examined as a moderator. Participants included two cohorts of sixth graders from 37 schools who were in dating relationships in the last 3 months at Wave 1, in the fall of sixth grade, and 6 months later at Wave 2, in the spring of sixth grade ( n = 2,022; 43% female; 55% Black, 17% Latino/a, 16% White, 9% as multiracial, and 3% as another race/ethnicity). Students reported on the frequency of dating violence in the past 3 months and substance use in the past 30 days. Multilevel models, with students at Level 1 and classes (i.e., clusters of students in the same cohort at the same school; n = 74) at Level 2, tested hypotheses that positive reciprocal relations between physical and psychological dating violence victimization and substance use would be found over time, and that relations would be stronger for girls than boys. Sex, race/ethnicity, and family structure variables were included as Level 1 covariates; intervention condition and neighborhood concentrated disadvantage were included as Level 2 covariates. Results showed that higher levels of physical dating violence victimization at Wave 1 predicted increased substance use at Wave 2. Higher levels of substance use at Wave 1 predicted increased physical and psychological dating violence victimization at Wave 2. Findings highlight the importance of prevention efforts for dating violence and substance use early in adolescence.

  3. Polyp Detection and Segmentation from Video Capsule Endoscopy: A Review

    Directory of Open Access Journals (Sweden)

    V. B. Surya Prasath

    2016-12-01

    Full Text Available Video capsule endoscopy (VCE is used widely nowadays for visualizing the gastrointestinal (GI tract. Capsule endoscopy exams are prescribed usually as an additional monitoring mechanism and can help in identifying polyps, bleeding, etc. To analyze the large scale video data produced by VCE exams, automatic image processing, computer vision, and learning algorithms are required. Recently, automatic polyp detection algorithms have been proposed with various degrees of success. Though polyp detection in colonoscopy and other traditional endoscopy procedure based images is becoming a mature field, due to its unique imaging characteristics, detecting polyps automatically in VCE is a hard problem. We review different polyp detection approaches for VCE imagery and provide systematic analysis with challenges faced by standard image processing and computer vision methods.

  4. 99mTc-DTPA aerosol for same-day post-perfusion ventilation imaging: Results of a multicentre study

    International Nuclear Information System (INIS)

    Koehn, H.; Koenig, B.; Bachmayr, S.; Markt, B.; Eber, O.; Lind, P.; Galvan, G.; Rettenbacher, L.; Holm, C.; Ogris, E.

    1993-01-01

    A multicentre study was performed in an attempt to evaluate a submicronic technetium-99m diethylene triamine penta-acetic acid aerosol generated by a newly developed delivery system, the aerosol production equipment (APE nebulizer), for same-day post-perfusion ventilation imaging in patients with clinically suspected pulmonary embolism. Quantitative comparison between the DTPA aerosol and krypton gas demonstrated a close correlation with respect to regional pulmonary distribution of activity and peripheral lung penetration (n=14, r=0.94, P 99m Tc-labelled DTPA aerosol is well suited for fast same-day post-perfusion ventilation imaging in patients with clinical suspicion of pulmonary embolism. (orig.)

  5. Bidirectional Retroviral Integration Site PCR Methodology and Quantitative Data Analysis Workflow.

    Science.gov (United States)

    Suryawanshi, Gajendra W; Xu, Song; Xie, Yiming; Chou, Tom; Kim, Namshin; Chen, Irvin S Y; Kim, Sanggu

    2017-06-14

    Integration Site (IS) assays are a critical component of the study of retroviral integration sites and their biological significance. In recent retroviral gene therapy studies, IS assays, in combination with next-generation sequencing, have been used as a cell-tracking tool to characterize clonal stem cell populations sharing the same IS. For the accurate comparison of repopulating stem cell clones within and across different samples, the detection sensitivity, data reproducibility, and high-throughput capacity of the assay are among the most important assay qualities. This work provides a detailed protocol and data analysis workflow for bidirectional IS analysis. The bidirectional assay can simultaneously sequence both upstream and downstream vector-host junctions. Compared to conventional unidirectional IS sequencing approaches, the bidirectional approach significantly improves IS detection rates and the characterization of integration events at both ends of the target DNA. The data analysis pipeline described here accurately identifies and enumerates identical IS sequences through multiple steps of comparison that map IS sequences onto the reference genome and determine sequencing errors. Using an optimized assay procedure, we have recently published the detailed repopulation patterns of thousands of Hematopoietic Stem Cell (HSC) clones following transplant in rhesus macaques, demonstrating for the first time the precise time point of HSC repopulation and the functional heterogeneity of HSCs in the primate system. The following protocol describes the step-by-step experimental procedure and data analysis workflow that accurately identifies and quantifies identical IS sequences.

  6. Videoscopic Heller Myotomy with Intraoperative Endoscopy Promotes Optimal Outcomes

    Science.gov (United States)

    Bloomston, Mark; Brady, Patrick

    2002-01-01

    Background and Objectives: Minimally invasive surgical techniques are applicable to achalasia, but the optimum approach to intraoperative assessment of adequacy of myotomy remains unestablished. We set out to show that videoscopic Heller myotomy with concurrent endoscopy ensures adequacy of myotomy while limiting postoperative clinically apparent reflux. Methods: Seventy-eight consecutive patients with achalasia underwent videoscopic Heller myotomy with concomitant endoscopy between 1992 and 1998. Fundoplication was not routinely undertaken. Results: Preoperative symptoms consisted of dysphagia (100%), emesis/regurgitation (68%), heartburn (58%), and postprandial chest pain (49%). Following myotomy, significant improvement (P Heller myotomy guides the extent and adequacy of myotomy. By utilizing a focused dissection with preservation of the natural antireflux mechanisms around the gastroesophageal junction and limiting the extent of myotomy along the cardia, postoperative reflux symptoms are minimized. We advocate concomitant endoscopy during Heller myotomy to guide myotomy and submit that routine fundoplication is clinically unnecessary. PMID:12113416

  7. A literature review of quality in lower gastrointestinal endoscopy from the patient perspective

    OpenAIRE

    Sewitch, Maida J; Gong, Shasha; Dubé, Catherine; Barkun, Alan; Hilsden, Robert; Armstrong, David

    2011-01-01

    BACKGROUND: Given the limited state of health care resources, increased demand for colorectal cancer (CRC) screening raises concerns about the quality of endoscopy services. Little is known about quality in colonoscopy and endoscopy from the patient perspective.OBJECTIVE: To systematically review the literature on quality that is relevant to patients who require colonoscopy or endoscopy services.METHODS: A systematic PubMed search was performed on articles that were published between January ...

  8. A novel bidirectional expression system for simultaneous expression of both the protein-coding genes and short hairpin RNAs in mammalian cells

    International Nuclear Information System (INIS)

    Hung, C.-F.; Cheng, T.-L.; Wu, R.-H.; Teng, C.-F.; Chang, W.-T.

    2006-01-01

    RNA interference (RNAi) is an extremely powerful and widely used gene silencing approach for reverse functional genomics and molecular therapeutics. In mammals, the conserved poly(ADP-ribose) polymerase 2 (PARP-2)/RNase P bidirectional control promoter simultaneously expresses both the PARP-2 protein and RNase P RNA by RNA polymerase II- and III-dependent mechanisms, respectively. To explore this unique bidirectional control system in RNAi-mediated gene silencing strategy, we have constructed two novel bidirectional expression vectors, pbiHsH1 and pbiMmH1, which contained the PARP-2/RNase P bidirectional control promoters from human and mouse, for simultaneous expression of both the protein-coding genes and short hairpin RNAs. Analyses of the dual transcriptional activities indicated that these two bidirectional expression vectors could not only express enhanced green fluorescent protein as a functional reporter but also simultaneously transcribe shLuc for inhibiting the firefly luciferase expression. In addition, to extend its utility for the establishment of inherited stable clones, we have also reconstructed this bidirectional expression system with the blasticidin S deaminase gene, an effective dominant drug resistance selectable marker, and examined both the selection and inhibition efficiencies in drug resistance and gene expression. Moreover, we have further demonstrated that this bidirectional expression system could efficiently co-regulate the functionally important genes, such as overexpression of tumor suppressor protein p53 and inhibition of anti-apoptotic protein Bcl-2 at the same time. In summary, the bidirectional expression vectors, pbiHsH1 and pbiMmH1, should provide a simple, convenient, and efficient novel tool for manipulating the gene function in mammalian cells

  9. Cost-effective bidirectional digitized radio-over-fiber systems employing sigma delta modulation

    Science.gov (United States)

    Lee, Kyung Woon; Jung, HyunDo; Park, Jung Ho

    2016-11-01

    We propose a cost effective digitized radio-over-fiber (D-RoF) system employing a sigma delta modulation (SDM) and a bidirectional transmission technique using phase modulated downlink and intensity modulated uplink. SDM is transparent to different radio access technologies and modulation formats, and more suitable for a downlink of wireless system because a digital to analog converter (DAC) can be avoided at the base station (BS). Also, Central station and BS share the same light source by using a phase modulation for the downlink and an intensity modulation for the uplink transmission. Avoiding DACs and light sources have advantages in terms of cost reduction, power consumption, and compatibility with conventional wireless network structure. We have designed a cost effective bidirectional D-RoF system using a low pass SDM and measured the downlink and uplink transmission performance in terms of error vector magnitude, signal spectra, and constellations, which are based on the 10MHz LTE 64-QAM standard.

  10. Bidirectional ventricular tachycardia of unknown etiology

    International Nuclear Information System (INIS)

    Ali, M.; Khan, J.A.; Masood, T.; Shamsi, F.; Dero, M.H.; Khan, S.

    2013-01-01

    A 45 years old male presented to the emergency department with palpitations, headache and apprehension. His electrocardiogram revealed bidirectional ventricular tachycardia. He remained vitally stable and responded to intravenous beta-blocker. Initially digitalis toxicity was suspected but history was negative for digitalis intake. The cause remained unidentified in patient despite detailed investigations. During a short follow-up (of 6 months) he remained asymptomatic and no cause was further identified during this period. Some other unseen causes of bidirectional ventricular tachycardia need to be explored. (author)

  11. Abdominal compression during endoscopy (the Bolster technique) demonstrates hidden Schatzki rings (with videos).

    Science.gov (United States)

    Jouhourian, Caroline; Bonis, Peter A; Guelrud, Moises

    2016-05-01

    Schatzki rings are found in the distal esophagus, are associated with hiatal hernias, and present with intermittent dysphagia to solid foods. They can be identified by radiology (GI series or barium swallow studies) or endoscopy. Rings are not always visualized during endoscopy in patients in whom they are suspected clinically. The Bolster technique involves application of epigastric abdominal pressure, which offers the potential to reveal a Schatzki ring that is otherwise obscured within a reduced hiatal hernia. The aim of this study was to determine whether the Bolster technique improves endoscopic detection of Schatzki rings. We reviewed 30 symptomatic patients with a history of a Schatzki ring in a tertiary care center. The Bolster technique was applied to patients in whom the ring was not visible during standard endoscopy. The main outcome measurement was identification of the Schatzki ring after the Bolster technique. A Schatzki ring was visible during standard endoscopy in 26 of the 30 patients. In the remaining 4, the ring was visible only after the application of the Bolster technique. The Bolster technique is a simple maneuver that can increase detection rates of Schatzki rings during endoscopy. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  12. Quantitative ENT endoscopy: the future in the new millennium

    Science.gov (United States)

    Mueller, Andreas; Schubert, Mario

    1999-06-01

    In Otorhinolaryngology the endoscopic appraisal of luminal dimensions of the nose, the throat, the larynx and the trachea is a daily problem. Those concerned with endoscopy know, that endoscopes distort dimensions of examined anatomical structures. To draw conclusions on luminal dimensions from the endoscopic pictures additional measuring devices are required. We developed a new method of measuring luminal dimensions in rigid or flexible endoscopy. For this a laser beam directed radially marks the anatomical lumen of interest in the videoendoscopic vision. The laser ring becomes deformed according to the form of the cavity explored. By keeping the distance defined between the laser ring and the top of the endoscope, the endoscopic video image can be measured. A piece of software developed by us calculates from the pictures the cross sectional area as well as the extension of benign or malign stenosis of the cavity explored. The result of the endoscopic measuring procedure can be visualized 3D on a PC-monitor. We are going to demonstrate the result of our clinical experience in different otorhinolaryngological diseases with the new endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic measuring kit in comparison to standard endoscopy. A further perspective is the endoscopic assisted manufacturing (EAM) of anatomical adapted stents, tubes and cannules.

  13. Upper Gastro-intestinal'Fibre-Optic Endoscopy

    African Journals Online (AJOL)

    1974-04-27

    Apr 27, 1974 ... A 3-YEAR STUDY AT GROOTE SCHUUR HOSPITAL. B. H. NOVIS, S. BANK, 1. .... ever, in 142 cases endoscopy provided a more definitive diagnosis or .... the best interests of the particular patient, related to the facilities and ...

  14. Limits on same-day billing in Medicaid hinders integration of behavioral health into the medical home model.

    Science.gov (United States)

    Roby, Dylan H; Jones, Erynne E

    2016-02-01

    The potential expansion of insurance coverage through the Patient Protection and Affordable Care Act of 2010 can facilitate the reduction of access barriers and improved quality for behavioral health care. More than 5 million of the newly insured are expected to have mental health and substance use disorders. In addition, state and federal efforts to integrate behavioral and medical health needs through patient-centered medical home models and innovations in payment strategies provide an unprecedented opportunity to use federal financial support to improve not only access to care, but also improve quality through active care coordination, use of interdisciplinary teams, colocating services, and engaging in warm hand-offs between providers in the same setting. These potential advances are hindered in 24 different states because of Medicaid payment policy, with 7 explicitly limiting the ability to reimburse for physical health and behavioral health services on the same day for all providers. Without the ability for providers to be reimbursed for different services on the same day to improve behavioral and medical health care coordination, these states could be limited in their ability to improve care via patient-centered approaches and interdisciplinary team-based care that would involve physicians, clinical psychologists, psychiatrists, and other mental health professionals. Limits on same-day billing in Medicaid programs could impact up to 36.7 million people in 24 states, which is approximately 52.6% of all Medicaid enrollees. (c) 2016 APA, all rights reserved).

  15. Barium enema and endoscopy for the detection of colorectal neoplasia: Sensitivity, specificity, complications and its determinants

    International Nuclear Information System (INIS)

    Zwart, Ingrid M. de; Griffioen, Gerrit; Shaw, M. Pertaap Chandie; Lamers, Cornelis B.H.W.; Roos, Albert de

    2001-01-01

    AIM: To analyse sensitivity, specificity and complication rate of endoscopy, and barium enema for the detection of colorectal neoplasia. MATERIALS AND METHODS: A MEDLINE search was performed (1980-2000) directed at the endoscopic and radiologic literature on barium enema. Articles were selected based on the type of study, availability of sensitivity and specificity values in sizeable patient groups, and reports on complications. Sixty articles were included in the analysis. RESULTS: Endoscopy proved to have superior sensitivity for polyps in patients at high-risk for colorectal neoplasia. The role of endoscopy and radiology in average-risk screening populations is not known. Sensitivity and specificity rates ranged widely, probably due to bias. For the detection of small polyps endoscopy has superior performance, whereas sensitivity is similar for endoscopy and barium enema for the detection of larger (>1 cm) polyps and tumours. Overall, endoscopy is associated with a higher complication rate. CONCLUSION: Endoscopy is the preferred detection method in high-risk patients. The role of endoscopy and radiology in a screening setting requires evaluation. This review provides the test characteristics of endoscopy and radiology which are relevant for a cost-effectiveness analysis. Double-contrast barium enema may play an important role for screening purposes, owing to its good sensitivity for detecting larger (>1 cm) polyps and its lack of major complications. Zwart, I.M. de et al. (2001)

  16. Appropriateness of Referrals for Upper Gastrointestinal Endoscopy ...

    African Journals Online (AJOL)

    Appropriateness of Referrals for Upper Gastrointestinal Endoscopy. ... Accra between January and December, 2008 were interviewed and evaluated for this study. ... Presentations with bleeding and suspicion of malignancy showed statistical ...

  17. Hindfoot endoscopy for posterior ankle pain

    NARCIS (Netherlands)

    van Dijk, C. Niek

    2006-01-01

    Hindfoot pain can be caused by a variety of pathologies, most of which can be diagnosed and treated with endoscopy. The main indications are posterior tibial tenosynovectomy, diagnosis of a longitudinal peroneus brevis rupture, peroneal tendon adhesiolysis, flexor hallucis longus release, os

  18. Diagnostic Performance of Magnifying Endoscopy for Helicobacter pylori Infection: A Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Qingqing Qi

    Full Text Available Diagnosis of Helicobacter pylori (H. pylori infection using magnifying endoscopy offers advantages over conventional invasive and noninvasive tests.This meta-analysis aimed to assess the diagnostic performance of magnifying endoscopy in the prediction of H. pylori infection.A literature search of the PubMed, Medline, EMBASE, Science Direct and the Cochrane Library databases was performed. A random-effects model was used to calculate the diagnostic efficiency of magnifying endoscopy for H. pylori infection. A summary receiver operator characteristic curve was plotted, and the area under the curve (AUC was calculated.A total of 18 studies involving 1897 patients were included. The pooled sensitivity and specificity of magnifying endoscopy to predict H. pylori infection were 0.89 [95% confidence interval (CI 0.87-0.91] and 0.82 (95%CI 0.79-0.85, respectively, with an AUC of 0.9461. When targeting the gastric antrum, the pooled sensitivity and specificity were 0.82 (95%CI 0.78-0.86 and 0.72 (95%CI 0.66-0.78, respectively. When targeting the gastric corpus, the pooled sensitivity and specificity were 0.92 (95%CI 0.90-0.94 and 0.86 (95%CI 0.82-0.88, respectively. The pooled sensitivity and specificity using magnifying white light endoscopy were 0.90 (95%CI 0.87-0.91 and 0.81 (95%CI 0.77-0.84, respectively. The pooled sensitivity and specificity using magnifying chromoendoscopy were 0.87 (95%CI 0.83-0.91 and 0.85 (95%CI 0.80-0.88, respectively. The "pit plus vascular pattern" classification in the gastric corpus observed by magnifying endoscopy was able to accurately predict the status of H. pylori infection, as indicated by a pooled sensitivity and specificity of 0.96 (95%CI 0.94-0.97 and 0.91 (95%CI 0.87-0.93, respectively, with an AUC of 0.9872.Magnifying endoscopy was able to accurately predict the status of H. pylori infection, either in magnifying white light endoscopy or magnifying chromoendoscopy mode. The "pit plus vascular pattern

  19. UPPER GASTROINTESTINAL ENDOSCOPY FINDINGS IN PATIENTS REFERRED WITH UPPER GASTROINTESTINAL SYMPTOMS IN ELDORET, KENYA: A RETROSPECTIVE REVIEW.

    Science.gov (United States)

    Ayuo, P O; Some, F F; Kiplagat, J

    2014-08-01

    Dyspepsia is one of the major indications for upper gastrointestinal endoscopy. Other indications include dysphagia, odynophagia and gastrointestinal bleeding. Endoscopy is an expensive procedure that is out of reach of many patients in resource constrained region such as western Kenya. We reviewed endoscopy records from both public and private health institutions spanning ten years. To determine the pattern of referral and endoscopy diagnoses in patients referred for upper gastrointestinal endoscopy in Eldoret, Kenya. Retrospective chart review. Moi Teaching and Referral Hospital, private hospitals and private clinics in Eldoret, Kenya. One thousand six hundred and ninety (1690) Patients who underwent upper GI endoscopy from 1993 to 2003 were reviewed after obtaining clearances from the respective institutions. Information on age, sex, symptoms, and endoscopy diagnosis were extracted and subjected to statistical analysis. The most common symptom was dyspepsia in 1059 (62.7%) followed by dysphagia in 224 (13.3%). Others were referred with diagnosis of cancer of the stomach or oesophagus. Common endoscopy diagnoses were cancer of the oesophagus in 199 (11.8%) and duodenal ulcer in 186 (11.0%). The majority of the patients (30.4%) had normal endoscopy findings. Of the 1059 patients with dyspepsia, only 154 (14.5%) had duodenal ulcer and 34 (3.2%) had gastric ulcers, the majority, 37.2% had normal endoscopy findings. Dyspepsia was main reason for referral, but the majority of such patients had normal findings. Cancer of the oesophagus was the main diagnosis in patients with dysphagia. In view of the cost of endoscopy, only those with dyspepsia and alarm symptoms be referred for the procedure.

  20. A Descriptive Survey of the Information Needs of Parents of Children Admitted for Same Day Surgery.

    LENUS (Irish Health Repository)

    Healy, Kathy

    2012-08-11

    Going to the hospital for surgery is an event that most people may find daunting. Anticipation of the unknown, lack of control over events and unfamiliarity with the environment may result in feelings of anxiety and stress. This research paper used a quantitative descriptive survey to establish the information needs of parents of children admitted for same day surgery. The main aims of this study were to establish what information parents had received prior to their child\\'s admission for same day surgery, and how they perceived this information. It also determined what other information they required. The findings demonstrated that the majority of parents in this study were satisfied with the information they had received. However they wanted further advice on the waiting times involved, the equipment used in the operating room department, pain relief and the procedures in the recovery room.

  1. Self-oscillating Galvanic Isolated Bidirectional Very High Frequency DC-DC Converter

    DEFF Research Database (Denmark)

    Pedersen, Jeppe Arnsdorf; Madsen, Mickey Pierre; Knott, Arnold

    2015-01-01

    This paper describes a galvanic isolated bidirectional Very High Frequency (VHF = 30 MHz - 300MHz) ClassE converter. The reason for increasing the switching frequency is to minimize the passive components in the converter. To make the converter topology bidirectional the rectifier has to be synch......This paper describes a galvanic isolated bidirectional Very High Frequency (VHF = 30 MHz - 300MHz) ClassE converter. The reason for increasing the switching frequency is to minimize the passive components in the converter. To make the converter topology bidirectional the rectifier has...

  2. Bidirectional reachability-based modules

    CSIR Research Space (South Africa)

    Nortje, R

    2011-07-01

    Full Text Available The authors introduce an algorithm for MinA extraction in EL based on bidirectional reachability. They obtain a significant reduction in the size of modules extracted at almost no additional cost to that of extracting standard reachability...

  3. Clearance of barium from the oesophagus with diet cola and metoclopramide: A one stop approach to patients with dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, J.; Farrow, R.; Hussaini, S.H.; Dalton, H.R

    2001-01-01

    AIM: To establish a 'one-stop' dysphagia service in which a consultation, barium swallow and endoscopy can all be performed in the same hospital visit. MATERIALS AND METHODS: In order to allow both barium swallow examination and endoscopy to be performed on the same day, a novel technique for clearing barium from the upper gastrointestinal tract was established. Following the barium swallow examination, patients were given diet cola and metoclopramide syrup. If appropriate, an upper gastrointestinal endoscopy was then performed shortly afterwards. The service was piloted for 6 months in which time 25 patients were investigated in this way. RESULTS: All patients were seen within 2 weeks of referral. The mean time between barium swallow and endoscopy was 3 h 38 min (range, 1 h 50 min to 5 h 20 min). In all 24 patients in whom an endoscopy was performed, barium had been satisfactorily cleared from the oesophagus and stomach. CONCLUSION: This technique allows both barium swallow and upper gastrointestinal endoscopy to be performed on the same day, providing a rapid, safe and accurate diagnosis with minimum patient inconvenience. Mitchell, J. (2001)

  4. Clearance of barium from the oesophagus with diet cola and metoclopramide: A one stop approach to patients with dysphagia

    International Nuclear Information System (INIS)

    Mitchell, J.; Farrow, R.; Hussaini, S.H.; Dalton, H.R.

    2001-01-01

    AIM: To establish a 'one-stop' dysphagia service in which a consultation, barium swallow and endoscopy can all be performed in the same hospital visit. MATERIALS AND METHODS: In order to allow both barium swallow examination and endoscopy to be performed on the same day, a novel technique for clearing barium from the upper gastrointestinal tract was established. Following the barium swallow examination, patients were given diet cola and metoclopramide syrup. If appropriate, an upper gastrointestinal endoscopy was then performed shortly afterwards. The service was piloted for 6 months in which time 25 patients were investigated in this way. RESULTS: All patients were seen within 2 weeks of referral. The mean time between barium swallow and endoscopy was 3 h 38 min (range, 1 h 50 min to 5 h 20 min). In all 24 patients in whom an endoscopy was performed, barium had been satisfactorily cleared from the oesophagus and stomach. CONCLUSION: This technique allows both barium swallow and upper gastrointestinal endoscopy to be performed on the same day, providing a rapid, safe and accurate diagnosis with minimum patient inconvenience. Mitchell, J. (2001)

  5. [Endoscopy-assisted sialolithectomy for the calculus of the Stensen's duct].

    Science.gov (United States)

    Ye, Xin; Xie, Xiaoyan; Liu, Denggao; Zhang, Lei; Zhang, Zuyan; Yu, Guangyan

    2014-11-01

    To investigate the clinical effects of endoscopy-assisted sialolithectomy for the calculus in the Stensen's duct. From August 2005 to July 2013, 67 consecutive patients with calculus (or foreign bodies) in the Stensen's duct underwent explorative and interventional endoscopy in our hospital. The stones (or foreign bodies) were removed by endoscopy-assisted technique. After operation, the patients were followed-up periodically, and treatment effects were analyzed. Among the 67 patients, the stones (or foreign bodies) were completely removed in 58 cases, and almost completely removed in 3 cases, with a success rate of 87% (58/67). Among the 61 stone-removed cases, treatment options included direct removal with aid of basket or forceps (24 cases), basket entrapment and opening-up of the ostium (21 cases), basket entrapment and mucosal incision near the ostium (8 cases), open removal via buccal incision (2 cases) and open removal via pre-auricular flap (6 cases). During the 6-90 months' follow-up of the 61 cases, 48 cases were asymptomatic, 7 had mild symptoms, 3 developed ductal obturation, 1 had numbness in the parotid region, and the remaining 2 were missed. Endoscopy-assisted sialolithectomy is a safe and effective gland-preservation technique for the patients with parotid gland calculus.

  6. Sentinel node biopsy (SNB) in malignant melanoma as same day procedure vs delayed procedure

    DEFF Research Database (Denmark)

    Rødgaard, Jes Christian; Kramer, Stine; Stolle, Lars B

    2013-01-01

    The aim of this study was to compare a delayed sentinel node biopsy (dSNB) procedure with a same-day procedure (sSNB) in malignant melanoma. In March 2012, Aarhus University Hospital went from the dSNB to the sSNB procedure defined by lymphoscintigraphy (LS) and sentinel node biopsy (SNB) perform......, essential to keep the morbidity and economic costs low, while keeping the quality of the procedure high....

  7. [Sedation with intravenous midazolam during upper gastrointestinal endoscopy--changes in hemodynamics, oxygen saturation and memory].

    Science.gov (United States)

    Mizuno, Ju; Matsuki, Michiko; Gouda, Yoshinori; Nishiyama, Tomoki; Hanaoka, Kazuo

    2003-09-01

    Cardiorespiratory adverse effects are often observed in patients undergoing upper gastrointestinal endoscopy with sedation. In this study, we examined hemodynamics, oxygen saturation and memory during upper gastrointestinal endoscopy under sedation with intravenous midazolam. Eight healthy outpatients without any obvious complications received intravenous midazolam 5 mg for sedation for upper gastrointestinal endoscopy. Blood pressure, heart rate and percutaneous arterial oxygen saturation (SpO2) were measured before, during and after endoscopy. After the arousal by intravenous flumazenil, we inquired the patients about the level of memory during the endoscopy. Blood pressure decreased significantly two minutes after midazolam administration, but increased significantly after the insertion of an endoscope which was not different from the control value. Heart rate increased significantly one and three minutes after the insertion of the endoscope. SpO2 decreased significantly after midazolam administration and stayed at around 95%. No patients remembered the procedure. Sedation with intravenous midazolam during upper gastrointestinal endoscopy is useful to control the cardiovascular responses, and to obtain amnesia. However, a decrease in SpO2 should be watched carefully.

  8. "Endoview" project of intrapartum endoscopy.

    Science.gov (United States)

    Petrikovsky, Boris M; Ravens, Steven

    2002-01-01

    The change in obstetrical practices over the last decade in favor of trials of labor in patients with uterine scars has resulted in increased incidences of uterine ruptures. Although neither repeat cesarean delivery nor a trial of labor is risk free, evidence from a large multicenter study shows vaginal birth after the cesarean (VBAC) is associated with shorter hospital stays, fewer postpartum blood transfusions, and a decreased incidence of postpartum maternal fever. The uterine rupture remains the most serious complication associated with VBAC. Factors associated with uterine rupture include excessive exposure to oxytocin, dysfunctional labor, and a history of more than 1 cesarean delivery.2 Because uterine rupture may be a life-threatening event, intrapartum surveillance and the ability to perform an emergency surgery are both necessary when trial of labor is allowed. Until now, no early symptoms pathognomonic to uterine rupture had been described. We share our experiences with the novel approach to the problem - an intrapartum endoscopy. Endoscopic examination was accomplished by using the intraoperational fiberscope (Olympus and Endoview system (Costa Mesa, CA, USA). A gas-sterilized 25-cm long fiberscope is introduced into the amniotic cavity through the cervical canal after rupture of the membranes. The distance between the fiberscope and the object varies from 3 to 50 mm. The fiberscope has a separate channel for the fluid infusion (normal saline) throughout the procedure; the surgeon looks through the eyepiece directly and exhibits control over the flexible scope. The duration of endoscopy is less than 15 minutes. The inserting of the endoscopic device is very similar to that of insertion of an intrauterine pressure catheter. The IRB Committees of both participating institutions approved the study protocol. Twenty-eight patients with an unknown or poorly documented site of the uterine scar were included in the study. An ultrasound examination had been

  9. Residents examine factors associated with 30-day, same-cause hospital readmissions on an internal medicine service.

    Science.gov (United States)

    Moran, Jennifer; Colbert, Colleen Y; Song, Juhee; Hull, Joshua; Rajan, Sabitha; Varghees, Sunita; Arroliga, Alejandro C; Reddy, Santosh P

    2013-01-01

    In recent years, there has been increased interest in stemming the tide of hospital readmissions in an attempt to improve quality of care. This study presents the Phase I results of a resident-led quality improvement initiative to determine the percentage of and risk factors for same-cause readmissions (SCRs; defined as hospital readmission within 30 days of hospital discharge for treatment of the same condition) to the internal medicine service of a multispecialty teaching hospital in central Texas. Results indicate that patients diagnosed with chronic obstructive pulmonary disease/asthma or anemia may be at increased risk for SCRs. Those patients who are insured by Medicaid and those who require assistance from social services also demonstrated an increased risk for SCRs. This study appears to be the first resident-led initiative in the field to examine 30-day SCRs to an internal medicine service for demographic and clinical risk factors.

  10. Bidirectional magnetic microactuators for uTAS

    Science.gov (United States)

    Hilbich, Daniel D.; Khosla, Ajit; Gray, Bonnie L.; Shannon, Lesley

    2011-02-01

    We present the design, fabrication and characterization of a novel bidirectional magnetic microactuator. The actuator has a planar structure and is easily fabricated using processes based on laser micromachining and soft lithography, allowing it to be readily integrated into microfluidic, microelectromechanical systems (MEMS) and lab-on-a-chip (LOC) designs. The new microactuator is a thin magnetic membrane with a central magnet feature. The membrane and magnet are both composed of a magnetic nanocomposite polymer (M-NCP) material that is fabricated by embedding magnetic powder in a polydimethysiloxane (PDMS) polymer matrix. The magnetic powder (MQP-12-5) has the chemical composition of (Nd0.7Ce0.3)10.5Fe83.9B5.6, and contains grains that are 5-6 microns in size. The powder is uniformly dispersed at a weight percentage of 75 wt-% in the PDMS matrix, and micropatterned using soft lithography micromolding to realize magnetic microstructures, which sit on a thinner magnetic PDMS membrane of the same material. The molds are fabricated by laser-etching into Poly (methyl methacrylate) (PMMA) using a Universal Laser System's VersaLASERlaser ablation system. The PDMS-based M-NCP is then poured and spun over the mold patterns, producing a thin polymer membrane to which the polymer micromagnets are attached, forming a one-piece actuator. The M-NCP is initially un-magnetized, but is then magnetized by placing it in a 2.5T magnetic field to produce permanent bidirectional magnetization that is polarized in the specified direction. To characterize the bidirectional actuators, a uniform magnetic field is established via a Helmholtz coil pair, and is characterized by applying varying currents. The magnetic field (and thus the actuator deflection) is controlled by regulating the current in the Helmholtz pair. Using this apparatus, deflection versus field characteristics are obtained, with maximum deflections varying as a function of actuator dimensions and the applied magnetic

  11. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anaesthesiologist administration of propofol for GI endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, J.M.; Riphaus, A.; Aparicio, J.R.

    2010-01-01

    Propofol sedation by non-anaesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim of this ev...

  12. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anesthesiologist administration of propofol for GI endoscopy

    DEFF Research Database (Denmark)

    Dumonceau, J.M.; Riphaus, A.; Aparicio, J.R.

    2010-01-01

    Propofol sedation by non-anesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim of this evi...

  13. European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and Associates, and the European Society of Anaesthesiology Guideline: Non-anesthesiologist administration of propofol for GI endoscopy

    NARCIS (Netherlands)

    Dumonceau, J. M.; Riphaus, A.; Aparicio, J. R.; Beilenhoff, U.; Knape, J. T. A.; Ortmann, M.; Paspatis, G.; Ponsioen, C. Y.; Racz, I.; Schreiber, F.; Vilmann, P.; Wehrmann, T.; Wientjes, C.; Walder, B.; Aabakken, L.; Axon, A.; Costamagna, G.; Giostra, E.; Hornslet, P.; Ladas, S.; Marek, T.; Dinis-Ribeiro, M.

    2010-01-01

    Propofol sedation by non-anesthesiologists is an upcoming sedation regimen in several countries throughout Europe. Numerous studies have shown the efficacy and safety of this sedation regimen in gastrointestinal endoscopy. Nevertheless, this issue remains highly controversial. The aim of this

  14. Comparison of a novel bedside portable endoscopy device with nasogastric aspiration for identifying upper gastrointestinal bleeding.

    Science.gov (United States)

    Choi, Jong Hwan; Choi, Jae Hyuk; Lee, Yoo Jin; Lee, Hyung Ki; Choi, Wang Yong; Kim, Eun Soo; Park, Kyung Sik; Cho, Kwang Bum; Jang, Byoung Kuk; Chung, Woo Jin; Hwang, Jae Seok

    2014-07-07

    To compare outcomes using the novel portable endoscopy with that of nasogastric (NG) aspiration in patients with gastrointestinal bleeding. Patients who underwent NG aspiration for the evaluation of upper gastrointestinal (UGI) bleeding were eligible for the study. After NG aspiration, we performed the portable endoscopy to identify bleeding evidence in the UGI tract. Then, all patients underwent conventional esophagogastroduodenoscopy as the gold-standard test. The sensitivity, specificity, and accuracy of the portable endoscopy for confirming UGI bleeding were compared with those of NG aspiration. In total, 129 patients who had GI bleeding signs or symptoms were included in the study (age 64.46 ± 13.79, 91 males). The UGI tract (esophagus, stomach, and duodenum) was the most common site of bleeding (81, 62.8%) and the cause of bleeding was not identified in 12 patients (9.3%). Specificity for identifying UGI bleeding was higher with the portable endoscopy than NG aspiration (85.4% vs 68.8%, P = 0.008) while accuracy was comparable. The accuracy of the portable endoscopy was significantly higher than that of NG in the subgroup analysis of patients with esophageal bleeding (88.2% vs 75%, P = 0.004). Food material could be detected more readily by the portable endoscopy than NG tube aspiration (20.9% vs 9.3%, P = 0.014). No serious adverse effect was observed during the portable endoscopy. The portable endoscopy was not superior to NG aspiration for confirming UGI bleeding site. However, this novel portable endoscopy device might provide a benefit over NG aspiration in patients with esophageal bleeding.

  15. Summary of Guidelines for Infection Prevention and Control for Flexible Gastrointestinal Endoscopy

    Directory of Open Access Journals (Sweden)

    Lawrence Hookey

    2013-01-01

    Full Text Available BACKGROUND: High-quality processes to ensure infection prevention and control in the delivery of safe endoscopy services are essential. In 2010, the Public Health Agency of Canada and the Canadian Association of Gastroenterology (CAG developed a Canadian guideline for the reprocessing of flexible gastrointestinal endoscopy equipment.

  16. Analytical investigation of bidirectional ductile diaphragms in multi-span bridges

    Science.gov (United States)

    Wei, Xiaone; Bruneau, Michel

    2018-04-01

    In the AASHTO Guide Specifications for Seismic Bridge Design Provisions, ductile diaphragms are identified as Permissible Earthquake-Resisting Elements (EREs), designed to help resist seismic loads applied in the transverse direction of bridges. When adding longitudinal ductile diaphragms, a bidirectional ductile diaphragm system is created that can address seismic excitations acting along both the bridge's longitudinal and transverse axes. This paper investigates bidirectional ductile diaphragms with Buckling Restrained Braces (BRBs) in straight multi-span bridge with simply supported floating spans. The flexibility of the substructures in the transverse and longitudinal direction of the bridge is considered. Design procedures for the bidirectional ductile diaphragms are first proposed. An analytical model of the example bridge with bidirectional ductile diaphragms, designed based on the proposed methodology, is then built in SAP2000. Pushover and nonlinear time history analyses are performed on the bridge model, and corresponding results are presented. The effect of changing the longitudinal stiffness of the bidirectional ductile diaphragms in the end spans connecting to the abutment is also investigated, in order to better understand the impact on the bridge's dynamic performance.

  17. Cross-species mapping of bidirectional promoters enables prediction of unannotated 5' UTRs and identification of species-specific transcripts

    Directory of Open Access Journals (Sweden)

    Lewin Harris A

    2009-04-01

    Full Text Available Abstract Background Bidirectional promoters are shared regulatory regions that influence the expression of two oppositely oriented genes. This type of regulatory architecture is found more frequently than expected by chance in the human genome, yet many specifics underlying the regulatory design are unknown. Given that the function of most orthologous genes is similar across species, we hypothesized that the architecture and regulation of bidirectional promoters might also be similar across species, representing a core regulatory structure and enabling annotation of these regions in additional mammalian genomes. Results By mapping the intergenic distances of genes in human, chimpanzee, bovine, murine, and rat, we show an enrichment for pairs of genes equal to or less than 1,000 bp between their adjacent 5' ends ("head-to-head" compared to pairs of genes that fall in the same orientation ("head-to-tail" or whose 3' ends are side-by-side ("tail-to-tail". A representative set of 1,369 human bidirectional promoters was mapped to orthologous sequences in other mammals. We confirmed predictions for 5' UTRs in nine of ten manual picks in bovine based on comparison to the orthologous human promoter set and in six of seven predictions in human based on comparison to the bovine dataset. The two predictions that did not have orthology as bidirectional promoters in the other species resulted from unique events that initiated transcription in the opposite direction in only those species. We found evidence supporting the independent emergence of bidirectional promoters from the family of five RecQ helicase genes, which gained their bidirectional promoters and partner genes independently rather than through a duplication process. Furthermore, by expanding our comparisons from pairwise to multispecies analyses we developed a map representing a core set of bidirectional promoters in mammals. Conclusion We show that the orthologous positions of bidirectional

  18. Piezoelectric power converter with bi-directional power transfer

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to a bi-directional piezoelectric power converter com¬ prising a piezoelectric transformer. The piezoelectric transformer comprises an input electrode electrically coupled to a primary section of the piezoelectric transformer and an output electrode electrically...... coupled to an output section of the piezoelectric transformer to provide a transformer output signal. A bi-directional switching circuit is coupled between the output electrode and a DC or AC output voltage of the power converter. Forward and reverse current conducting periods of the bi......, a reverse current is conducted through the bi-directional switching circuit from the DC or AC output voltage to the output electrode to discharge the DC or AC output voltage and return power to the primary section of the piezoelectric transformer....

  19. A 'same day' TSH radioimmunoassay kit with acceptable precision and accuracy

    International Nuclear Information System (INIS)

    Wood, W.G.; Muenchen Univ.

    1980-01-01

    A new 'same-day' TSH-RIA kit has been tested against an 'in-house' TSH-RIA, using incubation schemes of 4, 22 and 23 h. The kit standards were made up in human TSH-free serum and the method used a preincubation step and separation of bound and free antigen using a double antibody method. The correlation between the 'in-house' method and the kit was very good. The results in sera from TRH-test patients, and also from a recovery test with MRC 68/38 in human serum covering the range 0-50 mU/l were good. A comparison of the new kit was made with its precedessor which had protein based standards highlighted the need for standards in human TSH-free serum seen by the poor correlation (r = 0.619, n = 93). (orig.) [de

  20. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  1. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  2. Novel disposable transnasal endoscopy for assessment of esophageal motor function.

    Science.gov (United States)

    Lim, Chul-Hyun; Choi, Myung-Gyu; Baeg, Myong-Ki; Moon, Sung Jin; Kim, Jin Su; Cho, Yu Kyung; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Kyu Yong

    2014-01-01

    A novel disposable transnasal endoscopy (DTE) with a portable system has been developed to provide unsedated esophagoscopy by modifying capsule endoscopy. The aim of this study was to assess the feasibility of DTE to evaluate esophageal motor function. Patients with or suspected esophageal motility disorders and healthy volunteers were enrolled. Participants underwent esophageal high-resolution manometry and DTE in random order on different days. Motility was observed with DTE at 1, 8, and 16 cm above the gastroesophageal junction. Twenty healthy volunteers and 20 symptomatic subjects participated (8 achalasia, 5 scleroderma, 3 diffuse esophageal spasm, 1 hypertensive peristalsis, 1 peristaltic dysfunction, and 22 normal esophageal function). The normal findings on DTE were as follows. As the subject swallowed water, swallow-induced relaxation with elevation of the lower esophageal sphincter caused the endoscope to cross the Z-line into the gastric lumen. After the passage of water and air, complete closure of the lower esophageal sphincter occurred, with the return of the endoscope to its previous position. During the resting stage of the esophageal body, an air bubble could be seen in the center of the radially wrinkled and occluded lumen. The endoscopic diagnosis was in agreement with the clinical diagnosis in all but 2. Most of the participants reported acceptable discomfort during DTE and 62.5% of the subjects preferred DTE to manometry. DTE can accurately characterize normal esophageal motor function, allowing the diagnosis of esophageal motility disorders. DTE has potential widespread applications, especially in outpatient clinics.

  3. Stochastic Capsule Endoscopy Image Enhancement

    Directory of Open Access Journals (Sweden)

    Ahmed Mohammed

    2018-06-01

    Full Text Available Capsule endoscopy, which uses a wireless camera to take images of the digestive tract, is emerging as an alternative to traditional colonoscopy. The diagnostic values of these images depend on the quality of revealed underlying tissue surfaces. In this paper, we consider the problem of enhancing the visibility of detail and shadowed tissue surfaces for capsule endoscopy images. Using concentric circles at each pixel for random walks combined with stochastic sampling, the proposed method enhances the details of vessel and tissue surfaces. The framework decomposes the image into two detailed layers that contain shadowed tissue surfaces and detail features. The target pixel value is recalculated for the smooth layer using similarity of the target pixel to neighboring pixels by weighting against the total gradient variation and intensity differences. In order to evaluate the diagnostic image quality of the proposed method, we used clinical subjective evaluation with a rank order on selected KID image database and compared it to state-of-the-art enhancement methods. The result showed that the proposed method provides a better result in terms of diagnostic image quality and objective quality contrast metrics and structural similarity index.

  4. A STUDY OF CORRELATION BETWEEN NASAL ENDOSCOPY AND CT SCAN IN CASES OF CHRONIC RHINOSINUSITIS

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-07-01

    Full Text Available BACKGROUND: The accurate diagnosis of Chronic Rhinosinusitis (CRS is still a challenge therefore, the American Academy of Otorhinolaryngology - Head and Neck Surgery (AAO - HNS 1 has met in a multidisciplinary encounter and formulated a consensus based on only clinical symptoms. The computed tomography (CT scan and the nasal endoscopy (NE were introduced to make an accurate diagnosis of CRS and verify the disease severity. AIM: The aim of this study is to make a correlation between nasal endoscopy and CT scan in cases of clinically diagnosed Chronic Rhinosinusitis patients. METHOD: A study was carried out on 90 patients at Jhalawar Medical College, Jhalawar (Raj. during Sept. 20 12 to Dec. 2014. Diagnostic Nasal Endoscopy and CT Scan PNS done in patients, suffering from Chronic Rhinosinusitis. As a classification instruments, Metson / Gliklich's classification was used to evaluate the tomographic diagnosis and the Stankiewicz / Chow' s classification to evaluate the endoscopic diagnosis of Chronic Rhinosinusitis. RESULTS: Our study showed high specificity of endoscopy in comparison to CT scan though CT scan results are more sensitive. CONCLUSION: Endoscopy can confirm a Chronic Rhinosi nusitis diagnosis, but cannot rule it out, and that CT should be performed in cases of suspected CRS even if mucopurulence is not noted on endoscopy. The CT scan and the nasal endoscopy making easier the treatment planning and the disease resolution.

  5. Integrable hydrodynamics of Calogero-Sutherland model: bidirectional Benjamin-Ono equation

    International Nuclear Information System (INIS)

    Abanov, Alexander G; Bettelheim, Eldad; Wiegmann, Paul

    2009-01-01

    We develop a hydrodynamic description of the classical Calogero-Sutherland liquid: a Calogero-Sutherland model with an infinite number of particles and a non-vanishing density of particles. The hydrodynamic equations, being written for the density and velocity fields of the liquid, are shown to be a bidirectional analog of the Benjamin-Ono equation. The latter is known to describe internal waves of deep stratified fluids. We show that the bidirectional Benjamin-Ono equation appears as a real reduction of the modified KP hierarchy. We derive the chiral nonlinear equation which appears as a chiral reduction of the bidirectional equation. The conventional Benjamin-Ono equation is a degeneration of the chiral nonlinear equation at large density. We construct multi-phase solutions of the bidirectional Benjamin-Ono equations and of the chiral nonlinear equations

  6. Comparing omeprazole with fluoxetine for treatment of patients with heartburn and normal endoscopy who failed once daily proton pump inhibitors: double-blind placebo-controlled trial.

    Science.gov (United States)

    Ostovaneh, M R; Saeidi, B; Hajifathalian, K; Farrokhi-Khajeh-Pasha, Y; Fotouhi, A; Mirbagheri, S S; Emami, H; Barzin, G; Mirbagheri, S A

    2014-05-01

    Patients with heartburn but without esophageal erosion respond less well to proton pump inhibitors (PPIs). There is a growing body of evidence implicating the role of psychological comorbidities in producing reflux symptoms. Pain modulators improve symptoms in patients with other functional gastrointestinal disorders. We aimed to compare the efficacy of fluoxetine with omeprazole and placebo to achieve symptomatic relief in patients with heartburn and normal endoscopy who failed once daily PPIs. Endoscopy-negative patients with heartburn who failed once daily PPIs were randomly allocated to receive 6 weeks treatment of fluoxetine, omeprazole, or placebo. Random allocation was stratified according to ambulatory pH monitoring study. Percentage of heartburn-free days and symptom severity was assessed. Sixty patients with abnormal and 84 patients with normal pH test were randomized. Subjects receiving fluoxetine experienced more improvement in percentage of heartburn-free days (median 35.7, IQR 21.4-57.1) than those on omeprazole (median 7.14, IQR 0-50, p heartburn-free days (median improvement, 57.1, IQR 35.7-57.1 vs 13.9, IQR, 0-45.6 and 7.14, 0-23.8, respectively, p heartburn and normal endoscopy who failed once daily PPIs. The superiority of fluoxetine was mostly attributed to those with normal esophageal pH rather than those with abnormal pH (ClinicalTrials.gov, number NCT01269788). © 2014 John Wiley & Sons Ltd.

  7. A Patient Flow Analysis: Identification of Process Inefficiencies and Workflow Metrics at an Ambulatory Endoscopy Unit

    Directory of Open Access Journals (Sweden)

    Rowena Almeida

    2016-01-01

    Full Text Available Background. The increasing demand for endoscopic procedures coincides with the paradigm shift in health care delivery that emphasizes efficient use of existing resources. However, there is limited literature on the range of endoscopy unit efficiencies. Methods. A time and motion analysis of patient flow through the Hotel-Dieu Hospital (Kingston, Ontario endoscopy unit was followed by qualitative interviews. Procedures were directly observed in three segments: individual endoscopy room use, preprocedure/recovery room, and overall endoscopy unit utilization. Results. Data were collected for 137 procedures in the endoscopy room, 139 procedures in the preprocedure room, and 143 procedures for overall room utilization. The mean duration spent in the endoscopy room was 31.47 min for an esophagogastroduodenoscopy, 52.93 min for a colonoscopy, 30.47 min for a flexible sigmoidoscopy, and 66.88 min for a double procedure. The procedure itself accounted for 8.11 min, 34.24 min, 9.02 min, and 39.13 min for the above procedures, respectively. The focused interviews identified the scheduling template as a major area of operational inefficiency. Conclusions. Despite reasonable procedure times for all except colonoscopies, the endoscopy room durations exceed the allocated times, reflecting the impact of non-procedure-related factors and the need for a revised scheduling template. Endoscopy units have unique operational characteristics and identification of process inefficiencies can lead to targeted quality improvement initiatives.

  8. A Patient Flow Analysis: Identification of Process Inefficiencies and Workflow Metrics at an Ambulatory Endoscopy Unit.

    Science.gov (United States)

    Almeida, Rowena; Paterson, William G; Craig, Nancy; Hookey, Lawrence

    2016-01-01

    Background. The increasing demand for endoscopic procedures coincides with the paradigm shift in health care delivery that emphasizes efficient use of existing resources. However, there is limited literature on the range of endoscopy unit efficiencies. Methods. A time and motion analysis of patient flow through the Hotel-Dieu Hospital (Kingston, Ontario) endoscopy unit was followed by qualitative interviews. Procedures were directly observed in three segments: individual endoscopy room use, preprocedure/recovery room, and overall endoscopy unit utilization. Results. Data were collected for 137 procedures in the endoscopy room, 139 procedures in the preprocedure room, and 143 procedures for overall room utilization. The mean duration spent in the endoscopy room was 31.47 min for an esophagogastroduodenoscopy, 52.93 min for a colonoscopy, 30.47 min for a flexible sigmoidoscopy, and 66.88 min for a double procedure. The procedure itself accounted for 8.11 min, 34.24 min, 9.02 min, and 39.13 min for the above procedures, respectively. The focused interviews identified the scheduling template as a major area of operational inefficiency. Conclusions. Despite reasonable procedure times for all except colonoscopies, the endoscopy room durations exceed the allocated times, reflecting the impact of non-procedure-related factors and the need for a revised scheduling template. Endoscopy units have unique operational characteristics and identification of process inefficiencies can lead to targeted quality improvement initiatives.

  9. PERFORATION AS A COMPLICATION OF THE DIAGNOSTIC UPPER AND LOWER ENDOSCOPY OF THE GASTROINTESTINAL TRACT

    Directory of Open Access Journals (Sweden)

    Ivailo P. Vazharov

    2012-08-01

    Full Text Available Purpose: The purpose of this examination is to evaluate the risk of perforation during endoscopy of upper and lower gastrointestinal tract.Patients and methods used: 1210 diagnostic gastroduodenoscopies and 412 colonoscopies of hospitalized patients were performed by two experienced endoscopists for the period March 2007 – March 2012 at MHAT Varna, MMA. The endoscopies were performed without premedication and sedation. The patients were examined for complications of the procedure during and after the endoscopy. One of the most serious complications is the perforation of the oesophagus, stomach or the large intestine.Results: We had no perforations caused by the examination during the 1210 upper endoscopies performed. We had 2 perforations (0,48% from the 412 colonoscopies performed, which were treated successfully surgically.Conclusions: The perforation is a rare but serious complication of the endoscopy of gastrointestinal tract, which can be healed completely.

  10. Spiral CT biliary virtual endoscopy: preliminary clinical applications in the detection of biliary calculus

    International Nuclear Information System (INIS)

    Xiong Minghui; Wang Dong; Song Yunlong; Zhang Wanshi; Xu Jiaxing

    2000-01-01

    Objective: To evaluate imaging features and clinical value of CT biliary virtual endoscopy in the detection of biliary calculus. Methods: Eighteen patients with biliary calculi underwent volume scanning using spiral CT (Hispeed Advantage CT/i GE ). All data were transferred to computer workstation, and CT biliary virtual endoscopy images with pseudocolor encoding were generated from the volumetric data using the Navigator Smooth soft-ware. All cases were proved by ultrasound, axial CT or operation. Results: Among 18 cases, gallstones were found 8 in cases, common bile duct stones in 2 cases, gallstones and bile duct stones in 6 cases. The stones were 0.3-3.2 cm in size. CT biliary virtual endoscopy correctly demonstrated the surface details of stones which were viewed from extra- or intraluminal orientation in a 3D fashion. The findings were consistent with those of US, CT or operation. Conclusion: The CT virtual biliary endoscopy is a further development of virtual endoscopy for observing biliary calculus from intra- and extra-luminal views and providing three dimensional information of stone

  11. Individual polyp detection rate in routine daily endoscopy practice depends on case-mix.

    Science.gov (United States)

    Loffeld, R J L F; Liberov, B; Dekkers, P E P

    2015-07-01

    The adenoma detection rate (ADR), a marker of endoscopic quality, is confounded by selection bias. It is not known what the ADR is in normal daily practice. To study the polyp detection rate (PDR) in different endoscopists in the course of years. All consecutive endoscopies of the colon done in 11 years were included. Endoscopies in the regular surveillance programme after polyp removal and after surgery because of colorectal cancer or diverticular disease were scored separately. The number of yearly procedures per endoscopist and presence of polyps, anastomoses, surveillance and cancer were noted. In the period of 11 years, 14,908 consecutive endoscopies of colon and rectum were done by four endoscopists. Two endoscopists had a significantly lower PDR than the other two (p case-mix of patients presented for endoscopy. This result debates the use of the ADR as quality indicator for individual endoscopists.

  12. A pilot study of same day sputum smear examination, its feasibility and usefulness in diagnosis of pulmonary TB.

    Science.gov (United States)

    Myneedu, V P; Verma, A K; Sharma, P P; Behera, D

    2011-10-01

    A large number of tuberculosis cases are continuously being reported from India and other developing countries leading to high morbidity and mortality. In spite of many newer tests available for diagnosing a case of tuberculosis, smear microscopy of sputum is still the preferred test under programmatic conditions. The current national and international guidelines recommend two sputum smear examinations in two days for diagnosing cases of tuberculosis, which is time-consuming, tedious, needs multiple visits, leading to high dropout of infectious cases. In the background of existing limitations of smear microscopy, we attempted to complete the diagnosis of tuberculosis on same day by serial collection of the spot sputum specimen and analyze its advantages, feasibility and viability. The study was undertaken by the Department of Microbiology, Lala Ram Sarup Institute of Tuberculosis and Respiratory Diseases during May 2010 to April 2011. Sputum specimens were collected from 330 randomly selected tuberculosis suspects who attended OPD of hospital, patients submitted spot and home collected morning sputum sample in a standard method and spot and additional spot sputum (X- spot) collected one hour after the first spot sample as per the proposed front loading method. All the samples received were stained by acid fast Ziehl-Neelsen (ZN) stain and examined on the same day. The sputum sample was pooled and cultured in Lowenstein Jensen (LJ) media in duplicate set of bottles. The results of two different microscopic methods were compared with the gold standard culture test. Out of the total 330 TB suspects, 70.60% were males and 29.39% females. The most common complaint was of cough with sputum (88.18%), chest pain (70.21%), fever (55.15%) and loss of appetite (43.03%). Upon examining the total sputum slides, 18.48 % were positive for acid fast bacilli. The smear positivity was 61/330 (18.48%) by standard methods and in proposed new method 43/330 (13.03%). Sensitivity of the

  13. The endoscopy Global Rating Scale-Canada: development and implementation of a quality improvement tool.

    Science.gov (United States)

    MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; Veldhuyzen van Zanten, Sander; Daniels, Sandra; Ghattas, George

    2013-02-01

    Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes⁄no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide.

  14. A retrospective study of pediatric endoscopy as performed in an adult endoscopy unit Estudio retrospectivo sobre la endoscopia pediátrica desarrollada en un servicio de endoscopias de adultos

    Directory of Open Access Journals (Sweden)

    L. Julián-Gómez

    2010-02-01

    Full Text Available Gastrointestinal endoscopy is a safe, efficient technique with minimal complications, and a useful diagnostic tool for the pediatric population. Under ideal conditions endoscopies for children should be performed by experienced pediatric endoscopists. In this study we report our experience with pediatric endoscopy at the general adult endoscopy unit in our hospital. Our goal is to quantify the number of endoscopies performed in children, as well as their indications and findings, the type of sedation or anesthesia used, and the time waiting for the test to occur. Our experience demonstrates that endoscopists in a general adult gastroenterology department, working together with pediatricians, may perform a relevant number of endoscopies in children in a fast, safe, effective manner.La endoscopia gastrointestinal es una técnica segura y eficiente con mínimas complicaciones, así como una útil herramienta diagnóstica en la población pediátrica. En condiciones ideales, las endoscopias en niños deberían ser realizadas por endoscopistas pediátricos experimentados. En este estudio reportamos nuestra experiencia en la realización de endoscopias pediátricas en la Unidad de Endoscopias general de adultos de nuestro hospital. El objetivo es cuantificar la cantidad de endoscopias realizadas en niños, así como las indicaciones y hallazgos de las mismas, el tipo de sedación o anestesia empleado y el tiempo de espera para la realización de la prueba. Nuestra experiencia demuestra que los endoscopistas de un servicio de gastroenterología general de adultos, en colaboración con pediatras, pueden realizar un número importante de endoscopias a niños, de forma rápida, segura y eficaz.

  15. Canadian Association of Gastroenterology Consensus Guidelines on Safety and Quality Indicators in Endoscopy

    Directory of Open Access Journals (Sweden)

    David Armstrong

    2012-01-01

    Full Text Available Several organizations worldwide have developed procedure-based guidelines and/or position statements regarding various aspects of quality and safety indicators, and credentialing for endoscopy. Although important, they do not specifically address patient needs or provide a framework for their adoption in the context of endoscopy services. The consensus guidelines reported in this article, however, aimed to identify processes and indicators relevant to the provision of high-quality endoscopy services that will support ongoing quality improvement across many jurisdictions, specifically in the areas of ethics, facility standards and policies, quality assurance, training and education, reporting standards and patient perceptions.

  16. [Clinical symptoms of erosive and ulcerous lesions of gastroduodenal zone in patients with unstable ischemic heart disease and the significance of endoscopy in diagnosis].

    Science.gov (United States)

    Osadchiĭ, V A; Chernin, V V; Barashkov, A P

    2003-01-01

    We studied 103 patients with unstable ischemic heart disease and clinical signs of gastroduodenal injury. Among them 62 (60.2%) patients had moderate gastric dyspepsia and abdominal pain during first 1-5 days of hospitalization. In 17 (16.5%) cases these clinical symptoms were accompanied with symptoms of gastroduodenal hemorrhage. Twenty four patients (23.3%) with history of ulcer disease or chronic gastritis, were asymptomatic. In 96 (93.2%) patients endoscopy performed mainly on days 20-24 of hospital stay detected gastroduodenal erosions and ulcers: acute ulcers were found in 19.4, acute erosions - in 40.8, exacerbations of peptic ulcer - in 33.0% of patients. Clinical symptoms of gastroduodenal ulcers and erosions often did not reflect character, severity and dynamics of pathological process. Therefore gastro- duodenoscopy had decisive importance for diagnosis and assessment of effect of treatment. Endoscopy should be carried out with due consideration of concomitant coronary pathology.

  17. Evolutionary Pseudo-Relaxation Learning Algorithm for Bidirectional Associative Memory

    Institute of Scientific and Technical Information of China (English)

    Sheng-Zhi Du; Zeng-Qiang Chen; Zhu-Zhi Yuan

    2005-01-01

    This paper analyzes the sensitivity to noise in BAM (Bidirectional Associative Memory), and then proves the noise immunity of BAM relates not only to the minimum absolute value of net inputs (MAV) but also to the variance of weights associated with synapse connections. In fact, it is a positive monotonically increasing function of the quotient of MAV divided by the variance of weights. Besides, the performance of pseudo-relaxation method depends on learning parameters (λ and ζ), but the relation of them is not linear. So it is hard to find a best combination of λ and ζ which leads to the best BAM performance. And it is obvious that pseudo-relaxation is a kind of local optimization method, so it cannot guarantee to get the global optimal solution. In this paper, a novel learning algorithm EPRBAM (evolutionary psendo-relaxation learning algorithm for bidirectional association memory) employing genetic algorithm and pseudo-relaxation method is proposed to get feasible solution of BAM weight matrix. This algorithm uses the quotient as the fitness of each individual and employs pseudo-relaxation method to adjust individual solution when it does not satisfy constraining condition any more after genetic operation. Experimental results show this algorithm improves noise immunity of BAM greatly. At the same time, EPRBAM does not depend on learning parameters and can get global optimal solution.

  18. Computer vision and augmented reality in gastrointestinal endoscopy

    Science.gov (United States)

    Mahmud, Nadim; Cohen, Jonah; Tsourides, Kleovoulos; Berzin, Tyler M.

    2015-01-01

    Augmented reality (AR) is an environment-enhancing technology, widely applied in the computer sciences, which has only recently begun to permeate the medical field. Gastrointestinal endoscopy—which relies on the integration of high-definition video data with pathologic correlates—requires endoscopists to assimilate and process a tremendous amount of data in real time. We believe that AR is well positioned to provide computer-guided assistance with a wide variety of endoscopic applications, beginning with polyp detection. In this article, we review the principles of AR, describe its potential integration into an endoscopy set-up, and envisage a series of novel uses. With close collaboration between physicians and computer scientists, AR promises to contribute significant improvements to the field of endoscopy. PMID:26133175

  19. The Utility of Endoscopic Biopsies in Patients with Normal Upper Endoscopy

    Directory of Open Access Journals (Sweden)

    Anouar Teriaky

    2016-01-01

    Full Text Available Background and Aims. Upper endoscopy is a valuable tool in the workup of gastrointestinal (GI complaints. The purpose of this study is to determine cost and yield of taking biopsies in a normal upper GI tract. Methods. This is a retrospective study where all upper GI biopsies were identified between May 2012 and April 2013, at a tertiary care center. Clinical, procedural, and pathology reports were reviewed to identify patient demographics, procedure information, and pathology diagnosis. Results. Biopsies of the upper GI tract were taken in 1297 patients with normal upper endoscopies. In patients with normal upper endoscopy, 22% of esophageal, 44% of gastric, and 12% of duodenal biopsies were abnormal. The most frequent abnormality was reflux esophagitis in 16% of esophageal biopsies, chronic gastritis in 23% of gastric biopsies, and increased intraepithelial lymphocytes in 6% of duodenal biopsies. The additional cost for taking biopsies in a normal upper GI tract for a diagnosis of eosinophilic esophagitis was $2963 Canadian (CAD, H. pylori associated gastritis was $1404 CAD, and celiac disease was $3024 CAD. Conclusions. The yield of biopsy in normal upper endoscopy varied with location, but the additional expense can be costly and should be tailored to appropriate clinical situations.

  20. [Rectocolonic polyps in Senegal. Results of 1500 lower endoscopies carried out at the Dakar General Hospital].

    Science.gov (United States)

    Peghini, M; Barabe, P; Seurat, P; Philippon, G; Morcillo, R; Diallo, A; Gueye, P M

    1987-01-01

    57 polyps were discovered during 1,500 low endoscopies, and 24 of them were adenoma. In the same period of time, 26 proctocolitic adenocarcinomas were found. Adenomatous polyps appear to be 5 times less frequent in Senegal than in industrialized countries and frequency of colitic cancer should be of the same frequency, that is far less negligible. Even if proctocolitic cancer does not set up any Public Health problems one could envisage systematic screening of polyadenoma in every patient aged more than 40. Proctosigmoid being the seat of most adenoma, fibrosigmoidoscopy appears well adapted to this kind of screening because it does not require any preparation, it is easy to perform and well accepted.

  1. Virtual reality simulation training for health professions trainees in gastrointestinal endoscopy.

    Science.gov (United States)

    Walsh, Catharine M; Sherlock, Mary E; Ling, Simon C; Carnahan, Heather

    2012-06-13

    Traditionally, training in gastrointestinal endoscopy has been based upon an apprenticeship model, with novice endoscopists learning basic skills under the supervision of experienced preceptors in the clinical setting. Over the last two decades, however, the growing awareness of the need for patient safety has brought the issue of simulation-based training to the forefront. While the use of simulation-based training may have important educational and societal advantages, the effectiveness of virtual reality gastrointestinal endoscopy simulators has yet to be clearly demonstrated. To determine whether virtual reality simulation training can supplement and/or replace early conventional endoscopy training (apprenticeship model) in diagnostic oesophagogastroduodenoscopy, colonoscopy and/or sigmoidoscopy for health professions trainees with limited or no prior endoscopic experience. Health professions, educational and computer databases were searched until November 2011 including The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, Scopus, Web of Science, Biosis Previews, CINAHL, Allied and Complementary Medicine Database, ERIC, Education Full Text, CBCA Education, Career and Technical Education @ Scholars Portal, Education Abstracts @ Scholars Portal, Expanded Academic ASAP @ Scholars Portal, ACM Digital Library, IEEE Xplore, Abstracts in New Technologies and Engineering and Computer & Information Systems Abstracts. The grey literature until November 2011 was also searched. Randomised and quasi-randomised clinical trials comparing virtual reality endoscopy (oesophagogastroduodenoscopy, colonoscopy and sigmoidoscopy) simulation training versus any other method of endoscopy training including conventional patient-based training, in-job training, training using another form of endoscopy simulation (e.g. low-fidelity simulator), or no training (however defined by authors) were included.  Trials comparing one method of virtual reality training versus

  2. Unmeasured improvement work: the lack of routinely collected, service-related data in NHS endoscopy units in England involved in "modernisation"

    Directory of Open Access Journals (Sweden)

    Hutchings Hayley A

    2008-01-01

    Full Text Available Abstract Background The availability of routinely collected service-related endoscopy data from NHS endoscopy units has never been quantified. Methods This retrospective observational study asked 19 endoscopy units to submit copies of all in-house, service-related endoscopy data that had been routinely collected by the unit – Referral numbers, Activity, Number of patients waiting and Number of lost slots. Nine of the endoscopy units had previously participated in the Modernising Endoscopy Services (MES project during 2003 to redesign their endoscopy services. These MES sites had access to additional funding and data collection software. The other ten (Control sites had modernised independently. All data was requested in two phases and corresponded to eight specific time points between January 2003 and April 2006. Results Only eight of 19 endoscopy units submitted routinely collected, service-related data. Another site's data was collected specifically for the study. A further two units claimed to routinely collect service-related data but did not submit any to the study. The remaining eight did not collect any service-related endoscopy data routinely and liaised with their Trust for data. Of the eight sites submitting service-related data, only three were MES project sites. Of these three, the data variables collected were limited and none collected the complete set of endoscopy data variables requested. Of the other five sites, two collected all four endoscopy data types. Data for the three MES project sites went back as far as January 2003, whilst the five Control sites were only able to submit data from December 2003 onwards. Conclusion There was a lack of service-related endoscopy data routinely collected by the study sites, especially those who had participated in the MES project. Without this data, NHS endoscopy services cannot have a true understanding of their services, cannot identify problems and cannot measure the impact of any

  3. The Topologies Research of a Soft Switching Bidirectional DC/DC Converter

    DEFF Research Database (Denmark)

    Zhang, Qi; Zhang, Yongping; Sun, Xiangdong

    2017-01-01

    A soft-switching solution implemented to the traditional bidirectional DC/DC converter is developed. The soft-switching cell, which composed of three auxiliary switches, one resonant capacitor and one resonant inductor, is equipped in the traditional bidirectional DC/DC converter to realize circuit...... circle. And the proposed topology of bidirectional soft-switching dc-dc converter(TASBC) performs ideal soft switching at boost operations. The characteristics of the proposed converter has been verified by MATLAB simulations and experimental results....

  4. Comparison of endoscopy and barium swallow with marshmallow in dysphagia.

    Science.gov (United States)

    Somers, S; Stevenson, G W; Thompson, G

    1986-06-01

    Forty-four patients with dysphagia were examined both by endoscopy and by barium swallow with a marshmallow bolus. In these patients 36 stenoses were found: 34 by radiology and 30 by endoscopy. The radiologic criteria for stenosis included arrest of the marshmallow in a manner to support a column of barium and reproduction of the patient's symptoms at the time this occurred. Radiologic false negative findings were partly due to an inability by patients to swallow an adequate marshmallow bolus; endoscopic failures were associated with small endoscopes and mild stenoses.

  5. Same-day diagnosis based on histology for women suspected of breast cancer: high diagnostic accuracy and favorable impact on the patient.

    Directory of Open Access Journals (Sweden)

    Maarten W Barentsz

    Full Text Available Same-day diagnosis based on histology is increasingly being offered to patients suspected of breast cancer. We evaluated to which extent same-day diagnosis affected diagnostic accuracy and patients' anxiety levels during the diagnostic phase.All 759 women referred for same-day evaluation of suspicious breast lesions between November 2011-March 2013 were included. Diagnostic accuracy was assessed by linking all patients to the national pathology database to identify diagnostic discrepancies, in which case slides were reviewed. Patients' anxiety was measured in 127 patients by the State Trait and Anxiety Inventory on six moments during the diagnostic workup and changes over time (< = 1 week were analyzed by mixed effect models.Core-needle biopsy was indicated in 374/759 patients (49.3% and in 205/759 (27% patients, invasive or in situ cancer was found. Final diagnosis on the same day was provided for 606/759 (79.8% patients. Overall, 3/759 (0.4% discordant findings were identified. Anxiety levels decreased significantly over time from 45.2 to 30.0 (P = <0.001. Anxiety levels decreased from 44.4 to 25.9 (P = <0.001 for patients with benign disease, and remained unchanged for patients diagnosed with malignancies (48.6 to 46.7, P = 0.933. Time trends in anxiety were not affected by other patient or disease characteristics like age, education level or (family history of breast cancer.Same-day histological diagnosis is feasible in the vast majority of patients, without impairing diagnostic accuracy. Patients' anxiety rapidly decreased in patients with a benign diagnosis and remained constant in patients with malignancy.

  6. The internal flow pattern analysis of a tidal power turbine operating on bidirectional generation-pumping

    International Nuclear Information System (INIS)

    Luo, Y Y; Xiao, Y X; Wang, Z W

    2013-01-01

    Using tidal energy can reduce environment pollution, save conventional energy and improve energy structure, hence it presents great advantage and is developing potential. Influenced by flood tide and low tide, a fully functional tidal power station needs to experience six operating modes, including bidirectional generation, pumping and sluice; the internal unsteady flow pattern and dynamic characters are very complicated. Based on a bidirectional tidal generator unit, three-dimensional unsteady flows in the flow path were calculated for four typical operating conditions with the pressure pulsation characteristics analyzed. According to the numerical results, the internal flow characteristics in the flow path were discussed. The influence of gravity to the hydraulic performance and flow characteristics were analysed. The results provide a theoretical analysis method of the hydraulic optimization design of the same type unit as well as a direction for stable operation and optimal scheduling of existing tidal power unit

  7. Ultrathin endoscopy versus high-resolution endoscopy for diagnosing superficial gastric neoplasia.

    Science.gov (United States)

    Toyoizumi, Hirobumi; Kaise, Mitsuru; Arakawa, Hiroshi; Yonezawa, Jin; Yoshida, Yukinaga; Kato, Masayuki; Yoshimura, Noboru; Goda, Ken-ichi; Tajiri, Hisao

    2009-08-01

    Ultrathin endoscopy (UTE) is an acceptable and cost-effective alternative to EGD with the patient under sedation, although the diagnostic accuracy of UTE is not well established. To compare the diagnostic accuracy of UTE and high-resolution endoscopy (HRE) for superficial gastric neoplasia. Prospective comparative study. Academic center. Patients with or without superficial gastric neoplasia underwent peroral UTE and HRE, back-to-back in a random order while under standard sedation. The procedures were performed by 2 endoscopists who were blinded to the clinical information. The rate of missed lesions and misdiagnosis, sensitivity, and specificity for the diagnosis of gastric neoplasia when using pathology as the reference standard. In total, 126 lesions (41 superficial gastric neoplasias, 85 nonneoplastic lesions) were recorded in 57 enrolled patients. For the diagnosis of gastric neoplasia, the sensitivity of UTE (58.5%) was significantly (P = .021) lower than that of HRE (78%), and the specificity of UTE (91.8%) was significantly (P = .014) lower than that of HRE (100%). The rate of missed lesions and misdiagnosis of gastric neoplasias when using UTE (41.5%) was significantly (P > .001) higher than that of HRE (22.0%). The corresponding rate of neoplasias at the proximal portion (fornix and corpus) when using UTE (29%) was significantly (P = .002) higher than that of HRE (7.2%), although the rates of neoplasias at the distal portion (angulus and antrum) were comparable for UTE and HRE. Small sample numbers in an enriched population. The diagnostic accuracy of UTE is significantly lower than that of HRE for superficial gastric neoplasia, and this difference is particularly striking for neoplasias in the proximal stomach. For UTE to be used as an alternative modality, improvements in optical quality and the incorporation of additional procedures, including close-range observations and chromoendoscopy, are required to enhance visualization.

  8. The effect of virtual endoscopy simulator training on novices: a systematic review.

    Directory of Open Access Journals (Sweden)

    Weiguang Qiao

    Full Text Available BACKGROUND: Advances in virtual endoscopy simulators have paralleled an interest in medical simulation for gastrointestinal endoscopy training. OBJECTIVE: The primary objective was to determine whether the virtual endoscopy simulator training could improve the performance of novices. DESIGN: A systematic review. SETTING: Randomized controlled trials (RCTs that compared virtual endoscopy simulator training with bedside teaching or any other intervention for novices were collected. PATIENTS: Novice endoscopists. INTERVENTIONS: The PRISMA statement was followed during the course of the research. The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, and ScienceDirect were searched (up to July 2013. Data extraction and assessment were independently performed. MAIN OUTCOME MEASUREMENTS: Independent procedure completion, total procedure time and required assistance. RESULTS: Fifteen studies (n = 354 were eligible for inclusion: 9 studies designed for colonoscopy training, 6 for gastroscopy training. For gastroscopy training, procedure completed independently was reported in 87.7% of participants in simulator training group compared to 70.0% of participants in control group (1 study; 22 participants; RR 1.25; 95% CI 1.13-1.39; P<0.0001. For colonoscopy training, procedure completed independently was reported in 89.3% of participants in simulator training group compared to 88.9% of participants in control group (7 study; 163 participants; RR 1.10; 95% CI 0.88-1.37; P = 0.41; I(2 = 85%. LIMITATIONS: The included studies are quite in-homogeneous with respect to training schedule and procedure. CONCLUSIONS: Virtual endoscopy simulator training might be effective for gastroscopy, but so far no data is available to support this for colonoscopy.

  9. A bidirectional shape memory alloy folding actuator

    International Nuclear Information System (INIS)

    Paik, Jamie K; Wood, Robert J

    2012-01-01

    This paper presents a low-profile bidirectional folding actuator based on annealed shape memory alloy sheets applicable for meso- and microscale systems. Despite the advantages of shape memory alloys—high strain, silent operation, and mechanical simplicity—their application is often limited to unidirectional operation. We present a bidirectional folding actuator that produces two opposing 180° motions. A laser-patterned nickel alloy (Inconel 600) heater localizes actuation to the folding sections. The actuator has a thin ( < 1 mm) profile, making it appropriate for use in robotic origami. Various design parameters and fabrication variants are described and experimentally explored in the actuator prototype. (paper)

  10. The Results of Upper Gastrointestinal Endoscopy Performed in Bayburt Province

    Directory of Open Access Journals (Sweden)

    Yavuz Ayar

    2013-09-01

    Full Text Available Aim: We analyzed the results of upper gastrointestinal endoscopy performed between November 2011 and January 2013 in the endoscopy unit at Bayburt State Hospital. Methods: Endoscopic analyses were done with a PENTAX EPK 100P equipment. The results were assessed retrospectively. Results: A total of 1008 patients (664 women, 344 men aged between 17 and 88 (mean: 50±18 years have undergone upper gastrointestinal endoscopy. 186 (18.4% patients were diagnosed with pangastritis, 81 - with esophagitis (8%, 68 - with antral gastritis (6.7%, 67 - with duodenal ulcer (6.6%, 57 - with gastric ulcer (5.6%, 35 - with alkaline reflux gastritis (3.6%, 21 - with duodenitis (2.1%, 5 - with gastric cancer (0.5%, 4 - with esophagial cancer (0.4%, 4 - with gastric polyp (0.4% and 3 patients were diagnosed with esophagial ulcer (0.3%. Conclusion: Lesions were most commonly observed in the stomach. Gastritis, esophagitis, duodenal and gastric ulcer were frequently observed in our city. (The Medical Bulletin of Haseki 2013; 51: 116-9

  11. Disparities in Receipt of FOBT versus Endoscopy among Filipino American Immigrants

    Science.gov (United States)

    Maxwell, Annette E.; Danao, Leda L.; Crespi, Catherine M.; Antonio, Cynthia; Garcia, Gabriel M.; Bastani, Roshan

    2009-01-01

    Background This report examines disparities associated with the type of colorectal screening test, fecal occult blood test (FOBT) versus endoscopy, within a particular racial/ethnic group, Filipino American immigrants. Methods Between July 2005 and October 2006, Filipino Americans age 50-75 from 31 community organizations in Los Angeles completed a 15-minute survey in English (65%) or Filipino (35%). Results Of the 487 respondents included in this analysis, 257 (53%) had never received any type of colorectal cancer (CRC) screening. Among the 230 subjects who had ever received a routine screening test, 78 had FOBT only (16% of the total sample) and 152 had endoscopy with or without FOBT (31% of the total sample). After controlling for access to care and key demographic variables in a multivariate analysis, only two characteristics distinguished between respondents who had FOBT only versus those who had endoscopy: acculturation, assessed by percent lifetime in the U.S. and language of interview, and income. Conclusions Our data suggest a two tier system, FOBT for less acculturated Filipino Americans with lower income versus endoscopy for Filipino immigrants with higher levels of acculturation and income. The disparity persists after adjusting for access to care. Instead of treating minority groups as monolithic, differences within groups need to be examined so that interventions can be appropriately targeted. PMID:18708385

  12. Prevalence of Helicobacter pylori in Northern Jordan: Endoscopy based study

    International Nuclear Information System (INIS)

    Bani-Hani, Kamal E.; Hammouri, Shadi M.

    2001-01-01

    Helicobacter pylori infection is considered the most common infection worldwide and is associated with many other disorders. The aim of this study is to determine the prevalence of this infection among patients undergoing endoscopy in Northern Jordan. Between November 1998 and September 2000, all patients referred from the Gastro-esophageal Clinic to the Endoscopy Unit at Princess Basma Teaching Hospital, Irbid, Northern Jordan were enrolled in this prospective study. For each patient clinical and epidemiological data was collected and endoscopy was performed. At least 3 antral biopsies were obtained from each patient, and these were examined histologically for the presence of gastritis and stained for Helicobacter pylori using modified Giemsa stain. A total of 197 consecutive patients (113 females) with a mean age of 40.2 years (range 15-91 years) were studied. Abdominal pain was the highest presenting symptom. Gastritis 91% and esophagitis 42% were the most frequent endoscopic findings. Gastritis was documented histologically in 183 (93%) of patients. Helicobacter pylori was found in 161 patients (82%), with all of these having histological gastritis. The 11 patients with gastric ulcer, compared to the 51 out of the 59 (86%) patients with duodenal ulcer, showed Helicobacter pylori in their biopsies. The prevalence of Helicobacter pylori infection in patients subjected to an upper gastrointestinal endoscopy in Jordan is high. This study confirms that Helicobacter pylori is significantly associated with gastritis and peptic ulcer. Further studies are needed to determine the types of Helicobacter pylori strains present in Jordan. (author)

  13. Autofluorescence imaging endoscopy can distinguish non-erosive reflux disease from functional heartburn: A pilot study.

    Science.gov (United States)

    Luo, Xi; Guo, Xiao-Xu; Wang, Wei-Feng; Peng, Li-Hua; Yang, Yun-Sheng; Uedo, Noriya

    2016-04-14

    To investigate whether autofluorescence imaging (AFI) endoscopy can distinguish non-erosive reflux disease (NERD) from functional heartburn (FH). In this prospective observational trial, 127 patients presenting with typical reflux symptoms for > 6 mo were screened. All the participants underwent endoscopy, during which white light imaging (WLI) was followed by AFI. Finally 84 patients with normal esophageal appearance on WLI were enrolled. It was defined as being suggestive of NERD if one or more longitudinal purple lines longer than one centimeter were visualized in the distal part of the esophagus during AFI endoscopy. Ambulatory 24-h multichannel intraluminal impedance and pH monitoring was also performed. After standard proton-pump inhibitor (PPI) tests, subjects were divided into an NERD group and an FH group and the diagnostic performance of AFI endoscopy to differentiate NERD from FH was evaluated. Of 84 endoscopy-negative patients, 36 (42.9%) had a normal pH/impedance test. Of these, 26 patients with favorable responses to PPI tests were classified as having NERD. Finally 10 patients were diagnosed with FH and the others with NERD. Altogether, 68 (81.0%) of the 84 patients were positive on AFI endoscopy. In the NERD group, there were 67 (90.5%) patients with abnormal esophageal findings on AFI endoscopy while only 1 (10%) patient was positive on AFI endoscopy in the FH group. The sensitivity and specificity of AFI in differentiating NERD from FH were 90.5% (95%CI: 81.5%-96.1%) and 90.0% (95%CI: 55.5%-99.7%), respectively. Meanwhile, the accuracy, positive predictive value and negative predictive value of AFI in differentiating between NERD and FH were 90.5% (95%CI: 84.2%-96.8%), 98.5% (95%CI: 92.1%-99.9%) and 56.3% (95%CI: 30.0%-80.2%), respectively. Autofluorescence imaging may serve as a complementary method in evaluating patients with NERD and FH.

  14. [Videocapsule endoscopy as a useful tool to diagnose primary intestinal lymphangiectasia].

    Science.gov (United States)

    Vignes, S; Bellanger, J

    2007-03-01

    Primary intestinal lymphangiectasia (Waldmann's disease) lead to a protein-losing enteropathy due to lymph leak into intestinal tract. A 28-year-old woman presented a bilateral lower limb lymphedema. Laboratory examination showing lymphopenia, hypoalbuminemia, hypogammaglobulinemia suggested the diagnosis of primary intestinal lymphangiectasia. Gastroscopy was normal and second duodenum biopsies were negative. Videocapsule endoscopy gave evidence of intestinal lymphangiectasia of the small bowel. Videocapsule endoscopy may be proposed to confirm intestinal lymphangiectasia and to precise their localization when gastroscopy is not conclusive.

  15. Contraindications for video capsule endoscopy

    OpenAIRE

    Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin

    2016-01-01

    Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn?s dise...

  16. Back-to-back colon capsule endoscopy and optical colonoscopy in colorectal cancer screening individuals

    DEFF Research Database (Denmark)

    Kobaek-Larsen, Morten; Kroijer, Rasmus; Dyrvig, Anne-Kirstine

    2018-01-01

    mm polyps in colon capsule endoscopy (97%; 95% CI: 94-100) was superior to colonoscopy (89%; 95% CI: 84-94). A complete capsule endoscopy examination (N=134) could detect patients with intermediate or greater risk (according to the European guidelines) with an accuracy, sensitivity, specificity...... and positivity rate of 79%, 93%, 69% and 58% respectively, using a cut-off of at least one polyp >10 mm or more than two polyps. CONCLUSION: Colon capsule endoscopy is superior to colonoscopy in polyp detection rate and per-patient sensitivity to >9 mm polyps, but only in complete CCE examinations. The rate...

  17. Loss Modelling and Experimental Verification of A 98.8% Efficiency Bidirectional Isolated DC-DC Converter

    Directory of Open Access Journals (Sweden)

    Ramachandran Rakesh

    2017-01-01

    In this paper, design and implementation of an ultra-high efficiency isolated bi-directional dc-dc converter utilizing GaN devices is presented. Loss modelling of the GaN converter is also included in this paper. The converter has achieved a maximum measured efficiency of 98.8% in both directions of power flow, using the same power components. Hardware prototype of the converter along with the measured efficiency curve is also presented in this paper.

  18. Hyperspectral Imaging Using Flexible Endoscopy for Laryngeal Cancer Detection

    Directory of Open Access Journals (Sweden)

    Bianca Regeling

    2016-08-01

    Full Text Available Hyperspectral imaging (HSI is increasingly gaining acceptance in the medical field. Up until now, HSI has been used in conjunction with rigid endoscopy to detect cancer in vivo. The logical next step is to pair HSI with flexible endoscopy, since it improves access to hard-to-reach areas. While the flexible endoscope’s fiber optic cables provide the advantage of flexibility, they also introduce an interfering honeycomb-like pattern onto images. Due to the substantial impact this pattern has on locating cancerous tissue, it must be removed before the HS data can be further processed. Thereby, the loss of information is to minimize avoiding the suppression of small-area variations of pixel values. We have developed a system that uses flexible endoscopy to record HS cubes of the larynx and designed a special filtering technique to remove the honeycomb-like pattern with minimal loss of information. We have confirmed its feasibility by comparing it to conventional filtering techniques using an objective metric and by applying unsupervised and supervised classifications to raw and pre-processed HS cubes. Compared to conventional techniques, our method successfully removes the honeycomb-like pattern and considerably improves classification performance, while preserving image details.

  19. Primary intestinal lymphangiectasia diagnosed by capsule endoscopy and double balloon enteroscopy

    Science.gov (United States)

    Oh, Tak Geun; Chung, Joo Won; Kim, Hee Man; Han, Seok-Joo; Lee, Jin Sung; Park, Jung Yeob; Song, Si Young

    2011-01-01

    Primary intestinal lymphangiectasia (PIL) is a rare disorder characterized by dilated intestinal lymphatics and the development of protein-losing enteropathy. Patients with PIL develop hypoalbuminemia, hypocalcemia, lymphopenia and hypogammaglobulinemia, and present with bilateral lower limb edema, fatigue, abdominal pain and diarrhea. Endoscopy reveals diffusely elongated, circumferential and polypoid mucosae covered with whitish enlarged villi, all of which indicate intestinal lymphangiectasia. Diagnosis is confirmed by characteristic tissue pathology, which includes dilated intestinal lymphatics with diffusely swollen mucosa and enlarged villi. The prevalence of PIL has increased since the introduction of capsule endoscopy. The etiology and prevalence of PIL remain unknown. Some studies have reported that several genes and regulatory molecules for lymphangiogenesis are related to PIL. We report the case of a patient with PIL involving the entire small bowel that was confirmed by capsule endoscopy and double-balloon enteroscopy-guided tissue pathology who carried a deletion on chromosome 4q25. The relationship between this deletion on chromosome 4 and PIL remains to be investigated. PMID:22110841

  20. The Endoscopy Global Rating Scale – Canada: Development And Implementation of a Quality Improvement Tool

    Directory of Open Access Journals (Sweden)

    Donald MacIntosh

    2013-01-01

    Full Text Available BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer.

  1. Same-day PCR testing of Salmonella in meat: from research to routine application at slaughterhouses

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey; Löfström, Charlotta; Josefsen, Mathilde Hartmann

    2011-01-01

    Development of a rapid PCR technique is described, which enables slaughterhouses to apply same-day testing for Salmonella in carcasses and fresh meat. The technique is based on a shortened pre-enrichment time and 1-h DNA purification using paramagnetic beads (or an easy-to-use boiling method) fol......) followed by Salmonella detection by real-time PCR. Final protocols have been approved for meat testing (fresh meat and carcass swabs) by the Nordval validation organization for Nordic countries....

  2. Fully wireless pressure sensor based on endoscopy images

    Science.gov (United States)

    Maeda, Yusaku; Mori, Hirohito; Nakagawa, Tomoaki; Takao, Hidekuni

    2018-04-01

    In this paper, the result of developing a fully wireless pressure sensor based on endoscopy images for an endoscopic surgery is reported for the first time. The sensor device has structural color with a nm-scale narrow gap, and the gap is changed by air pressure. The structural color of the sensor is acquired from camera images. Pressure detection can be realized with existing endoscope configurations only. The inner air pressure of the human body should be measured under flexible-endoscope operation using the sensor. Air pressure monitoring, has two important purposes. The first is to quantitatively measure tumor size under a constant air pressure for treatment selection. The second purpose is to prevent the endangerment of a patient due to over transmission of air. The developed sensor was evaluated, and the detection principle based on only endoscopy images has been successfully demonstrated.

  3. Bidirectional uncompressed HD video distribution over fiber employing VCSELs

    DEFF Research Database (Denmark)

    Estaran Tolosa, Jose Manuel; Vegas Olmos, Juan José; Rodes, G. A.

    2012-01-01

    We report on a bidirectional system in which VCSELs are simultaneously modulated with two uncompressed HD video signals. The results show a large power budget and a negligible penalty over 10 km long transmission links.......We report on a bidirectional system in which VCSELs are simultaneously modulated with two uncompressed HD video signals. The results show a large power budget and a negligible penalty over 10 km long transmission links....

  4. Outcomes of Propofol Sedation During Emergency Endoscopy Performed for Upper Gastrointestinal Bleeding.

    Science.gov (United States)

    Park, Chan Hyuk; Han, Dong Soo; Jeong, Jae Yoon; Eun, Chang Soo; Yoo, Kyo-Sang; Jeon, Yong Cheol; Sohn, Joo Hyun

    2016-03-01

    Although propofol-based sedation can be used during emergency endoscopy for upper gastrointestinal bleeding (UGIB), there is a potential risk of sedation-related adverse events, especially in patients with variceal bleeding. We compared adverse events related to propofol-based sedation during emergency endoscopy between patients with non-variceal and variceal bleeding. Clinical records of patients who underwent emergency endoscopy for UGIB under sedation were reviewed. Adverse events, including shock, hypoxia, and paradoxical reaction, were compared between the non-variceal and variceal bleeding groups. Of 703 endoscopies, 539 and 164 were performed for non-variceal and variceal bleeding, respectively. Shock was more common in patients with variceal bleeding compared to those with non-variceal bleeding (12.2 vs. 3.5%, P bleeding (non-variceal bleeding vs. variceal bleeding: hypoxia, 3.5 vs. 1.8%, P = 0.275; paradoxical reaction interfering with the procedure, 4.1 vs. 5.5%, P = 0.442). Although shock was more common in patients with variceal bleeding compared to those with non-variceal bleeding, most cases could be controlled without procedure interruption. Paradoxical reaction, rather than shock or hypoxia, was the most common cause of procedure interruption in patients with variceal bleeding, but the rate did not differ between patients with non-variceal and variceal bleeding.

  5. Is Endoscopy Really Necessary in My Case? A Four Year Retrospective Study.

    Science.gov (United States)

    Dinesh, H N; Kumar, Cd Jagadish; Sanjay, H M; Sachin, V; Basavaraju

    2015-07-01

    About 40% of the general population report dyspepsia at some time in their life making it a fairly common disease. Uncomplicated dyspepsia refers to patients whose dyspepsia is not accompanied by alarm features or associated with NSAIDS usage. To assess the need for UGI Endoscopy and find out the patterns of different endoscopic presentations in patients presenting with uncomplicated dyspepsia. Our study conducted in KR Hospital, Mysore, Department of General Surgery is a retrospective endoscopic study of 1450 patients with uncomplicated dysepsia. A significant 64% of the patients presenting with uncomplicated dyspepsia were found to have findings on endoscopy. The most common age range for positive endoscopic findings was 40-50 years in our hospital. Malignancy was diagnosed in 2.5% patients. We recommend upper GI endoscopy in patients presenting with uncomplicated dyspepsia for patients above 40 years of age in our hospital.

  6. The endoscopy Global Rating Scale – Canada: Development and implementation of a quality improvement tool

    Science.gov (United States)

    MacIntosh, Donald; Dubé, Catherine; Hollingworth, Roger; van Zanten, Sander Veldhuyzen; Daniels, Sandra; Ghattas, George

    2013-01-01

    BACKGROUND: Increasing use of gastrointestinal endoscopy, particularly for colorectal cancer screening, and increasing emphasis on health care quality highlight the need for endoscopy facilities to review the quality of the service they offer. OBJECTIVE: To adapt the United Kingdom Global Rating Scale (UK-GRS) to develop a web-based and patient-centred tool to assess and improve the quality of endoscopy services provided. METHODS: Based on feedback from 22 sites across Canada that completed the UK endoscopy GRS, and integrating results of the Canadian consensus on safety and quality indicators in endoscopy and other Canadian consensus reports, a working group of endoscopists experienced with the GRS developed the GRS-Canada (GRS-C). RESULTS: The GRS-C mirrors the two dimensions (clinical quality and quality of the patient experience) and 12 patient-centred items of the UK-GRS, but was modified to apply to Canadian health care infrastructure, language and current practice. Each item is assessed by a yes/no response to eight to 12 statements that are divided into levels graded D (basic) through A (advanced). A core team consisting of a booking clerk, charge nurse and the physician responsible for the unit is recommended to complete the GRS-C twice yearly. CONCLUSION: The GRS-C is intended to improve endoscopic services in Canada by providing endoscopy units with a straightforward process to review the quality of the service they provide. PMID:23472242

  7. Relationship between timing of endoscopy and mortality in patients with peptic ulcer bleeding

    DEFF Research Database (Denmark)

    Laursen, Stig B; Leontiadis, Grigorios I; Stanley, Adrian J

    2017-01-01

    BACKGROUND AND AIMS: The optimal timing of endoscopy in patients with peptic ulcer bleeding (PUB) remains unclear. The aim of this study was to examine the association between timing of endoscopy and mortality in PUB. METHODS: In a nationwide cohort study based on a database of consecutive patients...

  8. Esophageal stenting for benign and malignant disease : European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    Spaander, Manon C W; Baron, Todd H; Siersema, Peter D; Fuccio, Lorenzo; Schumacher, Brigitte; Escorsell, Àngels; Garcia-Pagán, Juan-Carlos; Dumonceau, Jean-Marc; Conio, Massimo; de Ceglie, Antonella; Skowronek, Janusz; Nordsmark, Marianne; Seufferlein, Thomas; Van Gossum, André; Hassan, Cesare; Repici, Alessandro; Bruno, Marco J

    2016-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE), endorsed by the European Society for Radiotherapy and Oncology (ESTRO), the European Society of Digestive Endoscopy (ESDO), and the European Society for Clinical Nutrition and Metabolism (ESPEN).

  9. Importance of age in outcome of oesophagogastroduodenoscopy in open access endoscopy: a profile of patients in Sub-Himalayan region of North India

    Directory of Open Access Journals (Sweden)

    B. Sharma

    2006-06-01

    Full Text Available The Oesophago-Gastro-Duodenoscopy (OGD is done in patients received by either open access system or the conventional system. The presenting complaints and OGD findings may differ among patients with age < 45 yrs and those who are more than 45 yrs old. The referral diagnosis, age, sex, and environmental factors have important implications on the chances of finding and objective abnormality on endoscopy in a patient. This study was aimed to evaluate to evaluate the profile of 1186 patients divided into younger (<45 yrs and older age (45 or > 45 yrs groups presenting for oesophago gastroduodenoscopy through open access referral system in sub-Himalayan region of North India. This is a retrospective study carried out on patients who underwent the OGD from Jan, 2004-Dec, 2004. The study was conducted in Indira Gandhi Medical College situated at a moderate altitude in North India. All patients presenting in Medical College during the study period for OGD were taken into study. The patients were divided into two groups based on age; less than 45 yrs and 45 yrs or more than 45 yrs. Their presenting complaint, age, sex, and OGD findings were recorded. The profile was compared between the two groups. A total of 1186 patients underwent OGD; the females were 451(38% and males were 735(62%; 616(52% were < 45 yrs old and 570(48% of the patients were 45 yrs or older. In the group I 431(70% had a normal endoscopy and 185(30% showed abnormal endoscopic findings. In group II 302(53% had a normal endoscopy, and 268(47% had abnormal findings on endoscopy. Gastric ulcers, mass lesion/new growth were more common in elderly group, Gastro-esophageal reflux disease (GERD was more common in younger group. The presenting complaints were similar in both groups. It is concluded that for the same presenting diagnosis the yield of OGD was more in patients > 45 yrs old. The positivity rate increased from 30% in < 45 yrs to 47% in the elderly cohort. So, all people >45 yrs

  10. Comparative study of image registration techniques for bladder video-endoscopy

    Science.gov (United States)

    Ben Hamadou, Achraf; Soussen, Charles; Blondel, Walter; Daul, Christian; Wolf, Didier

    2009-07-01

    Bladder cancer is widely spread in the world. Many adequate diagnosis techniques exist. Video-endoscopy remains the standard clinical procedure for visual exploration of the bladder internal surface. However, video-endoscopy presents the limit that the imaged area for each image is about nearly 1 cm2. And, lesions are, typically, spread over several images. The aim of this contribution is to assess the performance of two mosaicing algorithms leading to the construction of panoramic maps (one unique image) of bladder walls. The quantitative comparison study is performed on a set of real endoscopic exam data and on simulated data relative to bladder phantom.

  11. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis.

    Science.gov (United States)

    Canaval Zuleta, Héctor Julián; Company Campins, María M; Dolz Abadía, Carlos

    2016-06-01

    Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  12. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis

    Directory of Open Access Journals (Sweden)

    Héctor Julian Canaval-Zuleta

    Full Text Available Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  13. The use of selective serotonin receptor inhibitors (SSRIs) is not associated with increased risk of endoscopy-refractory bleeding, rebleeding or mortality in peptic ulcer bleeding.

    Science.gov (United States)

    Laursen, S B; Leontiadis, G I; Stanley, A J; Hallas, J; Schaffalitzky de Muckadell, O B

    2017-08-01

    Observational studies have consistently shown an increased risk of upper gastrointestinal bleeding in users of selective serotonin receptor inhibitors (SSRIs), probably explained by their inhibition of platelet aggregation. Therefore, treatment with SSRIs is often temporarily withheld in patients with peptic ulcer bleeding. However, abrupt discontinuation of SSRIs is associated with development of withdrawal symptoms in one-third of patients. Further data are needed to clarify whether treatment with SSRIs is associated with poor outcomes, which would support temporary discontinuation of treatment. To identify if treatment with SSRIs is associated with increased risk of: (1) endoscopy-refractory bleeding, (2) rebleeding or (3) 30-day mortality due to peptic ulcer bleeding. A nationwide cohort study. Analyses were performed on prospectively collected data on consecutive patients admitted to hospital with peptic ulcer bleeding in Denmark in the period 2006-2014. Logistic regression analyses were used to investigate the association between treatment with SSRIs and outcome following adjustment for pre-defined confounders. Sensitivity and subgroup analyses were performed to evaluate the validity of the findings. A total of 14 343 patients were included. Following adjustment, treatment with SSRIs was not associated with increased risk of endoscopy-refractory bleeding (odds ratio [OR] [95% Confidence Interval (CI)]: 1.03 [0.79-1.33]), rebleeding (OR [95% CI]: 0.96 [0.83-1.11]) or 30-day mortality (OR [95% CI]: 1.01 [0.85-1.19]. These findings were supported by sensitivity and subgroup analyses. According to our data, treatment with SSRIs does not influence the risk of endoscopy-refractory bleeding, rebleeding or 30-day mortality in peptic ulcer bleeding. © 2017 John Wiley & Sons Ltd.

  14. Global evaluation of ammonia bidirectional exchange and livestock diurnal variation schemes

    Science.gov (United States)

    Bidirectional air–surface exchange of ammonia (NH3) has been neglected in many air quality models. In this study, we implement the bidirectional exchange of NH3 in the GEOS-Chem global chemical transport model. We also introduce an updated diurnal variability scheme for NH3...

  15. Role of endoscopy in gastroesophageal reflux disease

    Directory of Open Access Journals (Sweden)

    Tarun Rai

    2015-01-01

    Full Text Available Gastroesophageal reflux disease is a condition due to reflux of stomach content in the esophagus causing trouble symptoms or complications or both. GERD is a clinical diagnosis and typically presents with a heartburn and/or regurgitation and a positive response to antacid secretory medications. GERD is the leading outpatient diagnosis among all gastrointestinal disorders in the United States. Approximately 40% of population report occasional symptoms of GERD whereas 10-20% of patients will have symptoms at least once in a week. Recent guidelines from gastrointestinal societies such as American College of Gastroenterology, American Society for Gastrointestinal Endoscopy and American College of Physicians have laid out specific indications regarding role of esophagogastroduodenoscopy in GERD. Despite these recommendations, studies have revealed that one-fifth to two-fifth EGDs may not be clinically indicated, especially where open access endoscopy referral system is used. Traditionally, GERD has been thought to be a disease of the western world. Prevalence rates had been estimated to be lower in Asia when compared to that of the Western Countries. Few recent epidemiological studies in India showed the prevalence of reflux disease in India to be between 8-24%, which is comparable to the western world. The use of EGDs becomes more critical for developing countries such as India where prevalence of GERD and BE is comparable to the western countries but have limited resources. In addition to direct cost for an EGD, it burdens economy with indirect costs such as time off from the work, transportation and any procedural complications. Risk stratifying patients with GERD may therefore prevent unnecessary procedures, harms and costs. The aim of this paper is to review the existing evidence on the role of endoscopy in GERD.

  16. Diagnosis and treatment of unexplained anemia with iron deficiency without overt bleeding

    DEFF Research Database (Denmark)

    Dahlerup, Jens Frederik; Eivindson, Martin; Jacobsen, Bent Ascanius

    2015-01-01

    A general overview is given of the causes of anemia with iron deficiency as well as the pathogenesis of anemia and the para-clinical diagnosis of anemia. Anemia with iron deficiency but without overt GI bleeding is associated with a risk of malignant disease of the gastrointestinal tract; upper...... gastrointestinal cancer is 1/7 as common as colon cancer. Benign gastrointestinal causes of anemia are iron malabsorption (atrophic gastritis, celiac disease, chronic inflammation, and bariatric surgery) and chronic blood loss due to gastrointestinal ulcerations. The following diagnostic strategy is recommended...... for unexplained anemia with iron deficiency: conduct serological celiac disease screening with transglutaminase antibody (IgA type) and IgA testing and perform bidirectional endoscopy (gastroscopy and colonoscopy). Bidirectional endoscopy is not required in premenopausal women

  17. Sedation-related complications in gastrointestinal endoscopy

    OpenAIRE

    Amornyotin, Somchai

    2013-01-01

    Sedation practices for gastrointestinal endoscopic (GIE) procedures vary widely in different countries depending on health system regulations and local circumstances. The goal of procedural sedation is the safe and effective control of pain and anxiety, as well as to provide an appropriate degree of memory loss or decreased awareness. Sedation-related complications in gastrointestinal endoscopy, once occurred, can lead to significant morbidity and occasional mortality in patients. The risk fa...

  18. Bidirectional semantic associations between social power and weight.

    Science.gov (United States)

    He, Xiaoling; Chen, Jun; Li, Jianan

    2018-02-01

    Two experiments were conducted to examine bidirectional semantic associations between power and weight using a priming paradigm. Bidirectionality in the relationship between power and weight was demonstrated, utilising tasks that were identical except that the orders in which the stimuli were presented were reversed. In Experiment 1, an empty scale leaning either leftward or rightward was used as a priming stimulus, and a scale that appeared in equilibrium with a pair of power words was used as a target stimulus. In Experiment 2, a scale with a pair of words that appeared in equilibrium was used as a priming stimulus, and an empty scale leaning either leftward or rightward was used as a target stimulus. We identified interaction effects between power and weight in both experiments. Associations between power and weight provide evidence for both conceptual metaphor views and evolutionary theory. The bidirectionality of metaphorical effects is in line with the strong version of metaphoric structuring. Both language and experiential correlations play important roles in the development of the mapping between power and weight. © 2016 International Union of Psychological Science.

  19. Performance and cavitation characteristics of bi-directional hydrofoils

    Science.gov (United States)

    Nedyalkov, Ivaylo; Wosnik, Martin

    2013-11-01

    Tidal turbines extract energy from flows which reverse direction. One way to address this bi-directionality in horizontal axis turbines that avoid the use of complex and maintenance-intensive yaw or blade pitch mechanisms, is to design bi-directional blades which perform (equally) well in either flow direction. A large number of proposed hydrofoil designs were investigated using numerical simulations. Selected candidate foils were also tested (at various speeds and angles of attack) in the High-Speed Cavitation Tunnel (HICaT) at the University of New Hampshire. Lift and drag were measured using a force balance, and cavitation inception and desinence were recorded. Experimental and numerical results were compared, and the foils were compared to each other and to reference foils. Bi-directional hydrofoils may provide a feasible solution to the problem of reversing flow direction, when their performance and cavitation characteristics are comparable to those for unidirectional foils, and the penalty in decreased energy production is outweighed by the cost reduction due to lower complexity and respectively lower installation and maintenance costs.

  20. A psychophysically validated metric for bidirectional texture data reduction

    Czech Academy of Sciences Publication Activity Database

    Filip, Jiří; Chantler, M.J.; Green, P.R.; Haindl, Michal

    2008-01-01

    Roč. 27, č. 5 (2008), s. 138:1-138:11 ISSN 0730-0301 R&D Projects: GA AV ČR 1ET400750407; GA ČR GA102/08/0593 Institutional research plan: CEZ:AV0Z10750506 Keywords : Bidirectional Texture Functions * texture compression Subject RIV: BD - Theory of Information Impact factor: 3.383, year: 2008 http://library.utia.cas.cz/separaty/2008/RO/haindl-a psychophysically validated metric for bidirectional texture data reduction.pdf

  1. Numerical Modelling of a Bidirectional Long Ring Raman Fiber Laser Dynamics

    Science.gov (United States)

    Sukhanov, S. V.; Melnikov, L. A.; Mazhirina, Yu A.

    2017-11-01

    The numerical model for the simulation of the dynamics of a bidirectional long ring Raman fiber laser is proposed. The model is based on the transport equations and Courant-Isaacson-Rees method. Different regimes of a bidirectional long ring Raman fiber laser and long time-domain realizations are investigated.

  2. A cerebrovascular stroke following endoscopy for an elderly patient ...

    African Journals Online (AJOL)

    Ahmed Gado

    2015-02-02

    Feb 2, 2015 ... gastrointestinal bleeding. Not only in upper gastrointestinal bleeding is advanced age a risk of ... plaining of hematemesis of large amount of coffee ground blood. ..... Green J. Complications of gastrointestinal endoscopy. BSG.

  3. Framewise phoneme classification with bidirectional LSTM and other neural network architectures.

    Science.gov (United States)

    Graves, Alex; Schmidhuber, Jürgen

    2005-01-01

    In this paper, we present bidirectional Long Short Term Memory (LSTM) networks, and a modified, full gradient version of the LSTM learning algorithm. We evaluate Bidirectional LSTM (BLSTM) and several other network architectures on the benchmark task of framewise phoneme classification, using the TIMIT database. Our main findings are that bidirectional networks outperform unidirectional ones, and Long Short Term Memory (LSTM) is much faster and also more accurate than both standard Recurrent Neural Nets (RNNs) and time-windowed Multilayer Perceptrons (MLPs). Our results support the view that contextual information is crucial to speech processing, and suggest that BLSTM is an effective architecture with which to exploit it.

  4. Upper and Lower Urinary Tract Endoscopy Training on Thiel-embalmed Cadavers.

    Science.gov (United States)

    Bele, Uros; Kelc, Robi

    2016-07-01

    To evaluate Thiel-embalmed cadavers as a new training model for urological endoscopy procedures. Twelve urologists performed upper and lower urinary tract endoscopies on 5 different Thiel-embalmed cadavers to evaluate this potentially new training model in urological endoscopic procedural training. Using a 5-point Likert scale, the participants assessed the quality of the tissue and the overall experience of the endoscopy in comparison to a live patient procedure. Thiel-embalmed cadavers have shown to mimic live patient endoscopy of the upper and lower urinary tract in terms of almost identical overall anatomical conditions and manipulation characteristics of the tissue. The mucosa of the urethra and ureters showed similar colors and consistency in comparison to a live patient, whereas bladder mucosa was lacking the visibility of the vessels, thus was unsuitable for identifying any mucosal abnormalities. The flexibility of the muscles allowed for proper patient positioning, whereas the loss of muscle tonus made ureteroscopy more difficult although sufficiently comparable to the procedure done in a live patient. Thiel-embalmed cadavers have already been proven to be a suitable training model for several medical procedures. They are known for preserving tissue color, consistency, and flexibility without the irritant odors or risk of infection, which make them resemble live patients with real-life surgical challenges. The results of our study strongly suggest that despite some minor drawbacks, Thiel-embalmed cadavers are a suitable simulation model for initial training of urethrocystoscopy and ureteroscopy. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Constrained bidirectional propagation and stroke segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Mori, S; Gillespie, W; Suen, C Y

    1983-03-01

    A new method for decomposing a complex figure into its constituent strokes is described. This method, based on constrained bidirectional propagation, is suitable for parallel processing. Examples of its application to the segmentation of Chinese characters are presented. 9 references.

  6. Observation of rat's colon polyps in real time by mini-endoscopy and raman spectroscopy

    Science.gov (United States)

    Andriana, Bibin Bintang; Mahardika, Anggara; Taketani, Akihiro; Sato, Hidetoshi

    2018-02-01

    Colorectal adenoma (CA) is a disease caused by various factors (such as genetic factors or environmental exposures). The appearance of colon polyp (CP) within colorectal might indicate the hint of CA development. Ball-lens hollow fiber Raman probe (BHRP) may has a high capability for detection of CA in living experimental animal and have already tested to rat's CP in this study, which was designed to collaborate between BHRP with mini-endoscopy to observe the biochemical alteration within normal colon tissue and rat's colon polyps in real time. BHRP and mini-endoscopy can distinguish the differences in their finger print spectra and make pictures the control and CP in the real time. At the first step, the real situation of normal colon and Rat's CP were washed by saline and observed with mini-endoscopy. BHRP was introduced to Dextran sodium sulphate (DSS)-induced Rat's CP to detect some of biochemical alteration. The main purpose of this study was to introduce mini-endoscopy to guide the BHRP for diagnosing of CP in real time and to compare it with spectra of normal colon (control group) in living rat. As the result, BHRP can provide the differences in band of control and CP group, which can inform that the biochemical of normal and CP has changed. As a major parameter to distinct normal and CP tissue were phosphatidylinositol, phosphodiester group, lipid, and collagen. Mini endoscopy and BHRP is very sensitive devices for diagnosing of CP in real time.

  7. Endoscopic findings in patients with upper gastrointestinal bleeding clinically classified into three risk groups prior to endoscopy

    OpenAIRE

    Tammaro, Leonardo; Paolo, Maria Carla Di; Zullo, Angelo; Hassan, Cesare; Morini, Sergio; Caliendo, Sebastiano; Pallotta, Lorella

    2008-01-01

    AIM: To investigate in a prospective study whether a simplified clinical score prior to endoscopy in upper gastrointestinal bleeding (UGIB) patients was able to predict endoscopic findings at urgent endoscopy.

  8. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Guobing Pan

    2012-01-01

    Full Text Available Wireless capsule endoscopy (WCE offers a feasible noninvasive way to detect the whole gastrointestinal (GI tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE is the bottleneck. Wireless power transmission (WPT is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed.

  9. Technology Insight: current status of video capsule endoscopy.

    Science.gov (United States)

    Cave, David R

    2006-03-01

    Video capsule endoscopy (VCE) is the most recent major practical and conceptual development in the field of endoscopy. The video capsule endoscope-a small, pill-sized, passive imaging device-has been demonstrated to be the pre-eminent imaging device for disorders of the small intestine. The initial use for VCE was to detect the origin of obscure gastrointestinal bleeding. Several other indications have now been justified, or are in the process of evaluation. More than 200,000 of these disposable devices have been used worldwide, with an extraordinarily good safety record: indeed, the device has been approved for use in children as young as 10 years of age. In addition, a double-ended capsule has now been approved for the evaluation of mucosal disease in the esophagus. The now-widespread deployment of the device into gastrointestinal practice in the US and many other countries suggests that VCE has achieved mainstream utility. The development of similar competitor devices, and devices whose movement can be controlled, is in progress.

  10. The Application of Hemospray in Gastrointestinal Bleeding during Emergency Endoscopy

    Directory of Open Access Journals (Sweden)

    Alexander F. Hagel

    2017-01-01

    Full Text Available Introduction. Gastrointestinal bleeding represents the main indication for emergency endoscopy (EE. Lately, several hemostatic powders have been released to facilitate EE. Methods. We evaluated all EE in which Hemospray was used as primary or salvage therapy, with regard to short- and long-term hemostasis and complications. Results. We conducted 677 EE in 474 patients (488 examinations in 344 patients were upper GI endoscopies. Hemospray was applied during 35 examinations in 27 patients (19 males, 33 during upper and 2 during lower endoscopy. It was used after previous treatment in 21 examinations (60% and in 14 (40% as salvage therapy. Short-term success was reached in 34 of 35 applications (97.1%, while long-term success occurred in 23 applications (65.7%. Similar long-term results were found after primary application (64,3% or salvage therapy (66,7%. Rebleeding was found in malignant and extended ulcers. One major adverse event (2.8% occurred with gastric perforation after Hemospray application. Discussion. Hemospray achieved short-term hemostasis in virtually all cases. The long-term effect is mainly determined by the type of bleeding source, but not whether it was applied as first line or salvage therapy. But, even in the failures, patients had benefit from hemodynamic stabilization and consecutive interventions in optimized conditions.

  11. Outpatient blood pressure monitoring using bi-directional text messaging.

    Science.gov (United States)

    Anthony, Chris A; Polgreen, Linnea A; Chounramany, James; Foster, Eric D; Goerdt, Christopher J; Miller, Michelle L; Suneja, Manish; Segre, Alberto M; Carter, Barry L; Polgreen, Philip M

    2015-05-01

    To diagnose hypertension, multiple blood pressure (BP) measurements are recommended. We randomized patients into three groups: EMR-only (patients recorded BP measurements in an electronic medical record [EMR] web portal), EMR + reminders (patients were sent text message reminders to record their BP measurements in the EMR), and bi-directional text messaging (patients were sent a text message asking them to respond with their current BP). Subjects were asked to complete 14 measurements. Automated messages were sent to each patient in the bi-directional text messaging and EMR + reminder groups twice daily. Among 121 patients, those in the bi-directional text messaging group reported the full 14 measurements more often than both the EMR-only group (P text messaging is an effective way to gather patient BP data. Text-message-based reminders alone are an effective way to encourage patients to record BP measurements. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Bidirectional modulation of taste aversion extinction by insular cortex LTP and LTD.

    Science.gov (United States)

    Rodríguez-Durán, Luis F; Martínez-Moreno, Araceli; Escobar, Martha L

    2017-07-01

    The history of activity of a given neuron has been proposed to bidirectionally influence its future response to synaptic inputs. In particular, induction of synaptic plasticity expressions such as long-term potentiation (LTP) and long-term depression (LTD) modifies the performance of several behavioral tasks. Our previous studies in the insular cortex (IC), a neocortical region that has been related to acquisition and retention of conditioned taste aversion (CTA), have demonstrated that induction of LTP in the basolateral amygdaloid nucleus (Bla)-IC pathway before CTA training enhances the retention of this task. In addition, we reported that CTA training triggers a persistent impairment in the ability to induce in vivo LTP in the IC. The aim of the present study was to investigate whether LTD can be induced in the Bla-IC projection in vivo, as well as, whether the extinction of CTA is bidirectionally modified by previous synaptic plasticity induction in this pathway. Thus, rats received 900 train pulses (five 250μs pulses at 250Hz) delivered at 1Hz in the Bla-IC projection in order to induce LTD or 10 trains of 100Hz/1s with an intertrain interval of 20s in order to induce LTP. Seven days after surgery, rats were trained in the CTA task including the extinction trials. Our results show that the Bla-IC pathway is able to express in vivo LTD in an N-Methyl-D-aspartate (NMDA) receptor-dependent manner. Induction of LTD in the Bla-IC projection previous to CTA training facilitates the extinction of this task. Conversely, LTP induction enhances CTA retention. The present results show the bidirectional modulation of CTA extinction in response to IC-LTP and LTD, providing evidence of the homeostatic adaptation of taste learning. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. A programme for bidirectional phonology and phonetics and their acquisition and evolution

    NARCIS (Netherlands)

    Boersma, P.; Benz, A.; Mattausch, J.

    2011-01-01

    This paper summarizes an existing bidirectional six-level model of phonology and phonetics (and a bit of morphology). Bidirectionality in this case refers to the modelling of both the speaking process (production) and the listening process (comprehension). The elements of the grammar (the

  14. Automatic blood detection in capsule endoscopy video

    Czech Academy of Sciences Publication Activity Database

    Novozámský, Adam; Flusser, Jan; Tachecí, I.; Sulík, L.; Bureš, J.; Krejcar, O.

    2016-01-01

    Roč. 21, č. 12 (2016), s. 1-8, č. článku 126007. ISSN 1083-3668 R&D Projects: GA ČR GA15-16928S Institutional support: RVO:67985556 Keywords : Automatic blood detection * capsule endoscopy video Subject RIV: JD - Computer Applications, Robotics Impact factor: 2.530, year: 2016 http://library.utia.cas.cz/separaty/2016/ZOI/flusser-0466936.pdf

  15. Spillover between interparental conflict and parent-child conflict within and across days.

    Science.gov (United States)

    Sherrill, Rachel Baden; Lochman, John E; DeCoster, Jamie; Stromeyer, Sara L

    2017-10-01

    The present study used a daily reporting design to examine the bidirectional spillover in conflict and conflict strategies between the interparental relationship and the parent-child relationship. Participants were 60 parents with a preadolescent child at risk for aggressive behavior. Parents reported on their experience of interparental and parent-child conflict and their use of constructive and destructive conflict strategies through daily telephone interviews over 7 days. Each day was divided into 3 equal time periods roughly corresponding to early morning, daytime, and evening. Time-lagged analyses investigated the spillover in conflict within and across days. Results revealed that the presence of interparental conflict significantly predicted the presence of parent-child conflict 1 time period later and 1 full day later. Likewise, the presence of parent-child conflict significantly predicted the presence of interparental conflict 1 full day later. In terms of conflict strategy use, results revealed that parents who engaged in constructive patterns of interparental conflict were more likely to engage in constructive patterns of parent-child conflict 1 time period later and 1 full day later. Reciprocal effects for constructive parent-child conflict predicting subsequent interparental conflict were significant across all 3 time lags assessed. There were no significant, bidirectional effects for the spillover in destructive conflict. Findings have important clinical implications. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. First progress report on the Japan Endoscopy Database project.

    Science.gov (United States)

    Kodashima, Shinya; Tanaka, Kiyohito; Matsuda, Koji; Fujishiro, Mitsuhiro; Saito, Yutaka; Ohtsuka, Kazuo; Oda, Ichiro; Katada, Chikatoshi; Kato, Masayuki; Kida, Mitsuhiro; Kobayashi, Kiyonori; Hoteya, Shu; Horimatsu, Takahiro; Matsuda, Takahisa; Muto, Manabu; Yamamoto, Hironori; Ryozawa, Shomei; Iwakiri, Ryuichi; Kutsumi, Hiromu; Miyata, Hiroaki; Kato, Mototsugu; Haruma, Ken; Fujimoto, Kazuma; Uemura, Naomi; Kaminishi, Michio; Tajiri, Hisao

    2018-01-01

    The Japan Endoscopy Database (JED) Project was started to develop the world's largest endoscopic database, capture the actual performance of endoscopic practice, and standardize the terminology and fundamental items needed for a clinical and research registry. This paper presents a progress report on the first phase of this project undertaken at eight endoscopic centers in Japan. The list of data items to be collected was drafted by the MSED-J (Minimal Standard Endoscopic Database) subcommittee. These items were aggregated offline by integrating data from two endoscopic filing systems between July 2015 and December 2015. The study population included all patients who underwent esophagogastroduodenoscopy or colonoscopy at all eight centers, patients who underwent enteroscopy at five of the eight centers, and patients who underwent endoscopic retrograde cholangiopancreatography (ERCP) at four of the eight centers. Data collected in this phase included 61 070 endoscopic procedures, of which 40 475 were esophagogastroduodenoscopies, 215 were enteroscopies, 19 204 were colonoscopies, and 1176 were ERCPs. Frequencies of complications were 0.68% for esophagogastroduodenoscopy, 0% for enteroscopy, 0.43% for colonoscopy, and 13.34% for ERCP. In addition, we obtained various data including Helicobacter pylori infection status, past history of endoscopy in patients who underwent enteroscopy or colonoscopy, and degree of difficulty of ERCP, although the frequencies of reporting were sometimes low, with some items <20%. Results of the first phase suggest that the JED project can provide vast quantities of useful data about endoscopic procedures. © 2017 Japan Gastroenterological Endoscopy Society.

  17. Gastrointestinal mucosal abnormalities using videocapsule endoscopy in systemic sclerosis.

    Science.gov (United States)

    Marie, I; Antonietti, M; Houivet, E; Hachulla, E; Maunoury, V; Bienvenu, B; Viennot, S; Smail, A; Duhaut, P; Dupas, J-L; Dominique, S; Hatron, P-Y; Levesque, H; Benichou, J; Ducrotté, P

    2014-07-01

    To date, there are no large studies on videocapsule endoscopy in systemic sclerosis (SSc). Consequently, the prevalence and features of gastrointestinal mucosal abnormalities in SSc have not been determined. To determine both prevalence and characteristics of gastrointestinal mucosal abnormalities in unselected patients with SSc, using videocapsule endoscopy. To predict which SSc patients are at risk of developing potentially bleeding gastrointestinal vascular mucosal abnormalities. Videocapsule endoscopy was performed on 50 patients with SSc. Prevalence of gastrointestinal mucosal abnormalities was 52%. Potentially bleeding vascular mucosal lesions were predominant, including: watermelon stomach (34.6%), gastric and/or small intestinal telangiectasia (26.9%) and gastric and/or small intestinal angiodysplasia (38.5%). SSc patients with gastrointestinal vascular mucosal lesions more often exhibited: limited cutaneous SSc (P = 0.06), digital ulcers (P = 0.05), higher score of nailfold videocapillaroscopy (P = 0.0009), anaemia (P = 0.02), lower levels of ferritin (P correlation between gastrointestinal vascular mucosal lesions and presence of severe extra-digestive vasculopathy (digital ulcers and higher nailfold videocapillaroscopy scores). This latter supports the theory that SSc-related diffuse vasculopathy is responsible for both cutaneous and digestive vascular lesions. Therefore, we suggest that nailfold videocapillaroscopy may be a helpful test for managing SSc patients. In fact, nailfold videocapillaroscopy score should be calculated routinely, as it may result in identification of SSc patients at higher risk of developing potentially bleeding gastrointestinal vascular mucosal lesions. © 2014 John Wiley & Sons Ltd.

  18. Nurse management of 'same day' consultation for patients with minor illnesses: results of an extended programme in primary care in Catalonia.

    Science.gov (United States)

    Fabrellas, Núria; Vidal, Angel; Amat, Gemma; Lejardi, Yolanda; del Puig Deulofeu, Maria; Buendia, Carmen

    2011-08-01

    This paper is a report of a study to assess the feasibility and efficacy of a programme of nurse management for patients requesting same day consultation for minor illnesses in primary care. The efficacy of such programmes has been demonstrated in randomized studies but there is little information on these programmes in highly populated areas. Patients seeking same day consultation for one of 23 preselected minor illnesses (16 for adults, 7 for paediatric patients) from March 2009 to April 2010 were seen by trained nurses who followed predefined algorithms. If signs of alarm were detected, patients were referred to a general practitioner. A total of 629,568 consultations were performed, 575,189 in adults and 54,379 in paediatric patients. Case resolution was achieved in 61.8% of adult and 75.6% of paediatric patients. In adults, the highest resolution rates (>90%) were obtained for burns, skin injury and emergency contraception, and the lowest for lower urinary symptoms (46.7%), sore throat (45.7%), pink eye (45.5%) and upper respiratory symptoms (41.4%). In paediatric patients, the highest resolution rates (>90%) were obtained for stomach cramps and burns and the lowest for cough (36.2%). A return to consultation during a 7-day period for the same reason as the first consultation was low, 4% for adults and 2.4% for paediatric patients. An extended programme of nurse management for same day consultation of patients with minor illnesses showed an acceptably high rate of resolution and low rate of return to consultation. The application of such programmes in extensive areas is feasible and effective. © 2011 Blackwell Publishing Ltd.

  19. Network Coding in the Bidirectional Cross

    DEFF Research Database (Denmark)

    Ertli, Gergö; Paramanathan, Achuthan; Rein, Stephan Alexander

    2013-01-01

    This paper presents a detailed performance evaluation of inter-session network coding in wireless meshed networks in terms of throughput and energy consumption. A full analytical model is given for three different communication approaches for the bidirectional cross topology using an IEEE 802.11 ...

  20. A New Bi-Directional Projection Model Based on Pythagorean Uncertain Linguistic Variable

    Directory of Open Access Journals (Sweden)

    Huidong Wang

    2018-04-01

    Full Text Available To solve the multi-attribute decision making (MADM problems with Pythagorean uncertain linguistic variable, an extended bi-directional projection method is proposed. First, we utilize the linguistic scale function to convert uncertain linguistic variable and provide a new projection model, subsequently. Then, to depict the bi-directional projection method, the formative vectors of alternatives and ideal alternatives are defined. Furthermore, a comparative analysis with projection model is conducted to show the superiority of bi-directional projection method. Finally, an example of graduate’s job option is given to demonstrate the effectiveness and feasibility of the proposed method.

  1. Model based feasibility study on bidirectional check valves in wave energy converters

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.; Andersen, Torben Ole

    2014-01-01

    Discrete fluid power force systems have been proposed as the primary stage for Wave Energy Converters (WEC’s) when converting ocean waves into electricity, this to improve the overall efficiency of wave energy devices. This paper presents a model based feasibility study of using bidirectional check....../Off and bidirectional check valves. Based on the analysis it is found that the energy production may be slightly improved by using bidirectional check valves as compared to on/off valves, due to a decrease in switching losses. Furthermore a reduction in high flow peaks are realised. The downside being increased...

  2. PREVALENCE OF HELICOBACTER PYLORI TEN YEARS AGO COMPARED TO THE CURRENT PREVALENCE IN PATIENTS UNDERGOING UPPER ENDOSCOPY.

    Science.gov (United States)

    Frugis, Sandra; Czeczko, Nicolau Gregori; Malafaia, Osvaldo; Parada, Artur Adolfo; Poletti, Paula Bechara; Secchi, Thiago Festa; Degiovani, Matheus; Rampanazzo-Neto, Alécio; D Agostino, Mariza D

    2016-01-01

    Helicobacter pylori has been extensively studied since 1982 it is estimated that 50% of the world population is affected. The literature lacks studies that show the change of its prevalence in the same population over time. To compare the prevalence of H. pylori in 10 years interval in a population that was submitted to upper endoscopy in the same endoscopy service. Observational, retrospective and cross-sectional study comparing the prevalence of H. pylori in two samples with 10 years apart (2004 and 2014) who underwent endoscopy with biopsy and urease. Patients were studied in three consecutive months of 2004, compared to three consecutive months of 2014. The total number of patients was 2536, and 1406 in 2004 and 1130 in 2014. There were positive for H. pylori in 17 % of the sample as a whole. There was a significant decrease in the prevalence from 19.3% in 2004 to 14.1% in 2014 (pmundial esteja afetada. A literatura carece de estudos que mostrem a mudança de sua prevalência em uma mesma população ao longo do tempo. Comparar a prevalência do H.pylori no intervalo de 10 anos em população que realizou endoscopia digestiva alta no mesmo serviço de endoscopia. Estudo observacional, retrospectivo e transversal, comparando a prevalência de H. pylori em duas amostras com intervalo de 10 anos (2004 e 2014) que realizaram endoscopia digestiva alta com biópsias e teste da urease para a pesquisa de H. pylori. Foram estudados pacientes em três meses consecutivos de 2004, comparados aos de três meses consecutivos de 2014. O número total de pacientes avaliados foi 2536, sendo 1406 em 2004 e 1130 em 2014. Constatou-se resultado positivo para H.pylori em 17% da amostra como um todo. Houve queda significativa da prevalência de H.pylori de 19,3% em 2004 para 14,1% em 2014 (p<0.005). Houve redução de 5,2% da prevalência de H. pylori comparando-se dois períodos de três meses consecutivos com intervalo de 10 anos em duas amostras populacionais equivalentes.

  3. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Evidence-Based Analysis

    Science.gov (United States)

    2015-01-01

    Background Obscure gastrointestinal bleeding (OGIB) is defined as persistent or recurrent bleeding associated with negative findings on upper and lower gastrointestinal (GI) endoscopic evaluations. The diagnosis and management of patients with OGIB is particularly challenging because of the length and complex loops of the small intestine. Capsule endoscopy (CE) is 1 diagnostic modality that is used to determine the etiology of bleeding. Objectives The objective of this analysis was to review the diagnostic accuracy, safety, and impact on health outcomes of CE in patients with OGIB in comparison with other diagnostic modalities. Data Sources A literature search was performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, the Wiley Cochrane Library, and the Centre for Reviews and Dissemination database, for studies published between 2007 and 2013. Review Methods Data on diagnostic accuracy, safety, and impact on health outcomes were abstracted from included studies. Quality of evidence was assessed using Grading of Recommendations Assessment, Development, and Evaluation (GRADE). Results The search yielded 1,189 citations, and 24 studies were included. Eight studies reported diagnostic accuracy comparing CE with other diagnostic modalities. Capsule endoscopy has a higher sensitivity and lower specificity than magnetic resonance enteroclysis, computed tomography, and push enteroscopy. Capsule endoscopy has a good safety profile with few adverse events, although comparative safety data with other diagnostic modalities are limited. Capsule endoscopy is associated with no difference in patient health-related outcomes such as rebleeding or follow-up treatment compared with push enteroscopy, small-bowel follow-through, and angiography. Limitations There was significant heterogeneity in estimates of diagnostic accuracy, which prohibited a statistical summary of findings. The analysis was also limited by the fact that there is no

  4. Comparison of rigid and flexible endoscopy for removing esophageal foreign bodies in an emergency.

    Science.gov (United States)

    Tseng, Chia-Chen; Hsiao, Tzu-Yu; Hsu, Wei-Chung

    2016-08-01

    Despite the effectiveness of endoscopies in removing ingested foreign bodies (FBs) impacted in the esophagus, the merits and limitations of flexible endoscopy (FE) and rigid endoscopy (RE) remain unclear. Therefore, this study compares the advantages and disadvantages of both endoscopic procedures from a clinical perspective. A retrospective review was made of 273 patients suspected of esophageal FBs in emergency consultations of a tertiary medical referral center from March 2010 to March 2014. All patients received routine physical examinations, otolaryngological examinations, and X-rays of the neck and chest. The door-to-endoscopy time, procedure time, postendoscopic hospital stay, successful removal rates, and complications were analyzed as well. In this study, the most common esophageal FBs were fish and animal bones (76%) in adults and coins (74%) in children. The patients with existing esophageal FBs had significantly more frequent symptoms of dysphagia and signs of linear opacity as detected with lateral neck radiography than those without FB. Additionally, the door-to-endoscopy time, procedure time, and postendoscopic hospital stay was significantly shorter in FE patients than in RE patients. However, both RE and FE patients had high rates of successful FB removal (95%) and low complication rates (2%). Both FE and RE remove esophageal FBs successfully, as evidenced by their high success rates, low complication rates, and high detection rates. Although FE under local anesthesia is a less time-consuming procedure for adults, RE under general anesthesia may be preferable for children and can serve as an alternative to FE. Copyright © 2015. Published by Elsevier B.V.

  5. The comparison of upper endoscopy and scintigraphy results in the diagnostics of duodenogastric reflux

    International Nuclear Information System (INIS)

    Leja, M.; Lejnieks, A.; Pokrotnieks, J.; Sosare, L.; Reinholds, E.; Brezinskis, G.; Aboltins, A.

    2002-01-01

    The results of upper endoscopy in respect to the symptoms potentially indicative for duodenogastric reflux (DGR) have been compared to the results obtained by a scintigraphic method, elaborated by the group of the authors. Altogether 89 patients (48 women, 41 men) have been studied. For the analysis of signs indicative for functional disturbances of the upper digestive symptoms (status of the lower esophageal sphincter, gastric tone, presence of bile in the gastric content, status of the pyloric sphincter, influx of the duodenal content observed during the upper endoscopy, presence of the bile in the duodenum) the maximum accepted interval between the two investigations was 24 hours, while 1 month interval was accepted for the evaluations of structural changes (esophagitis, presence of hiatal hernis, gastritis and duodenitis, deformation of the pyloric sphincter and duodenal bulb. No statistically significant correlations has been found between any of the above mentioned parameters at upper endoscopy and the presence or absence of DGR as determined by the scintigraphic method. If a influx of the duodenal content into the stomach during the upper endoscopy, this could be considered as a specific indicator (specificity - 91,3%0, while the sensitivity (16,7%) is very low. There has been a trend to decreased DGR in patients with an atrophic gastritis, still this correlation was not statistically significant. The conclusion is made that the intubation of the stomach during the upper endoscopy could be causative for artificial DGR therefore leading to incorrect data interpretation and hyper diagnostics. (authors)

  6. Clinical radiology and endoscopy of the colon

    International Nuclear Information System (INIS)

    Reeders, J.W.A.J.; Rosenbusch, G.

    1994-01-01

    Translated from the original 1993 German edition, this comprehensive volume brings together, in a logically integrated, understandable teaching text, expert imaging by radiology, up-to-date ultrasound and MRI; endoscopy, and histology. This text does justice to the importance of the colon. Such integration of disciplines represents the way medicine should be practiced and taught, and this book will be a model for other subjects in gastroenterology and other organ systems in which different complementary diagnostic techniques are used. The illustrations are of high quality, and both the black and white radiographs and the color endoscopy and histology pictures are faithfully reproduced and supported with informative legends. The condensed text, in outline form, is complemented by an abundance of well-conceived, informative, and clear diagrams, tables, and line drawings. Taken together, this format provides rapid access to all the essential facts and appearances of normal and diseased colon for the casual as well as the serious reader. For the teachers and practitioners of gastroenterology or radiology, this book provides a gold mine of facts and ideas. References have been well selected and presented in an appendix. (orig./UHE)

  7. Featurized Bidirectional GAN: Adversarial Defense via Adversarially Learned Semantic Inference

    OpenAIRE

    Bao, Ruying; Liang, Sihang; Wang, Qingcan

    2018-01-01

    Deep neural networks have been demonstrated to be vulnerable to adversarial attacks, where small perturbations are intentionally added to the original inputs to fool the classifier. In this paper, we propose a defense method, Featurized Bidirectional Generative Adversarial Networks (FBGAN), to capture the semantic features of the input and filter the non-semantic perturbation. FBGAN is pre-trained on the clean dataset in an unsupervised manner, adversarially learning a bidirectional mapping b...

  8. Expanding Role of Third Space Endoscopy in the Management of Esophageal Diseases.

    Science.gov (United States)

    Yang, Dennis; Draganov, Peter V

    2018-03-01

    OPINION STATEMENT: "Third space" endoscopy, also commonly referred as submucosal endoscopy, is founded on the principle that the deeper layers of the gastrointestinal (GI) tract can be accessed by tunneling in the submucosal space without compromising the integrity of the overlying mucosa. Peroral endoscopic myotomy (POEM), endoscopic submucosal dissection (ESD), and submucosal tunneling endoscopic resection (STER) are innovative techniques within the field of third space endoscopy in the management of esophageal disorders. POEM has become an accepted minimally invasive therapy for achalasia and related motility disorders with excellent short-term results, with early studies yielding similar efficacy to surgical myotomy and increased durability when compared to pneumatic balloon dilation (PBD). Data are needed to establish long-term outcomes with POEM, with particular interest on the incidence of gastroesophageal reflux, which appears to be higher than initially anticipated. ESD, a mature endoscopic resection technique in Asia, has recently gained traction in the West as a viable option for the management of early Barrett's esophagus (BE) neoplasia. Compared to standard endoscopic mucosal resection (EMR), ESD allows the en bloc resection of lesions irrespective of size, which may facilitate histological interpretation and reduce recurrence rates. Large prospective randomized controlled trials are needed to validate the efficacy and safety of this technique and to further define its role in the endoscopic armamentarium in early BE neoplasia. STER is an attractive technique that theoretically permits the resection of subepithelial esophageal tumors (SETs) arising from the deeper GI layers. Initial studies from highly experienced endoscopic centers support its technical feasibility and safety, although these results should be interpreted with caution due to variability arising from small numbers and heterogeneity among studies. Overall, third space endoscopy is an

  9. Detection of Mucosal Recurrent Nasopharyngeal Carcinomas After Radiotherapy With Narrow-Band Imaging Endoscopy

    International Nuclear Information System (INIS)

    Wang, Wen-Hung; Lin, Yen-Chun; Chen, Wen-Cheng; Chen, Miao-Fen; Chen, Chih-Cheng; Lee, Kam-Fai

    2012-01-01

    Purpose: This study evaluated the feasibility of screening mucosal recurrent nasopharyngeal carcinoma with narrow-band imaging (NBI) endoscopy. Methods and Materials: One hundred and six patients were enrolled. All patients underwent conventional white-light (WL) endoscopic examination of the nasopharynx followed by NBI endoscopy. Biopsies were performed if recurrence was suspected. Results: We identified 32 suspected lesions by endoscopy in WL and/or NBI mode. Scattered brown spots (BS) were identified in 22 patients, and 4 of the 22 who had negative MRI findings were histopathologically confirmed to be neoplasias that were successfully removed via endoscopy. A comparison of the visualization in NBI closer view corresponded to histopathological findings in 22 BS, and the prevalence rates of neoplasias in tail signs, round signs, and irregularities signs were 0% (0/6), 0% (0/7), and 44.4% (4/9), respectively (p = 0.048). The sensitivity, specificity, and diagnostic capability were 37.5%, 92.9% and 0.652 for WL, 87.5%, 74.5% and 0.810 for NBI, and 87.5%, 87.8%, and 0.876 for NBI closer view, respectively. NBI closer view was effective in increasing specificity compared with NBI alone (87.8% vs. 74.5%, p < 0.05), and in increasing sensitivity and diagnostic capability compared to WL alone (87.5% vs. 37.5%, p < 0.05; 0.876 vs. 0.652, p = 0.0001). Conclusions: Although NBI in endoscopy can improve sensitivity of mucosal recurrent nasopharyngeal neoplasias, false-positive (nonneoplasia BS) results may be obtained in areas with nonspecific inflammatory changes due to postradiation effects. NBI closer view not only can offer a timely, convenient, and highly reliable assessment of mucosal recurrent nasopharyngeal carcinoma, it can also make endoscopic removal possible.

  10. Bilateral Coordination Strategy of Supply Chain with Bidirectional Option Contracts under Inflation

    Directory of Open Access Journals (Sweden)

    Nana Wan

    2015-01-01

    Full Text Available As far as the price increase and the demand contraction caused by inflation are concerned, we establish a Stackelberg game model that incorporates bidirectional option contracts and the effect of inflation and derive the optimal ordering and production policies on a one-period two-stage supply chain composed of one supplier and one retailer. Through using the model of wholesale price contracts as the benchmark, we find that the introduction of bidirectional option contracts can benefit both the supplier and the retailer under inflation scenarios. Based on the conclusions drawn above, we design the bilateral coordination mechanism from the different perspective of two members involved and discuss how bidirectional option contracts should be set to achieve channel coordination under inflation scenarios. Through the sensitivity analysis, we illustrate the effect of inflation on the optimal decision variables and the optimal expected profits of the two parties with bidirectional option contracts.

  11. Provision of a 'same-day' ultrasound service in an inner-city NHS trust: report on experience and lessons learned after the first 2 years

    International Nuclear Information System (INIS)

    Hawtin, K.E.; Hameed, S.; Ramachandran, R.; Harvey, C.J.; Lim, A.K.; Gishen, P.; Roddie, M.E.

    2010-01-01

    Aim: To assess the effect of changing from an 'appointment' to a 'same-day' ultrasound (US) service on referral pattern, departmental workload, and patient satisfaction. Materials and methods: To reduce US waiting time of 3 weeks for routine examinations, a 'same-day' service was started for outpatients and general practitioner (GP) patients in September 2006. To examine the effect of this change a retrospective assessment was performed of workload during 1 week in June 2006 (appointments only) and the same week in 2008, 22 months after the implementation of the new service. Distance travelled by patients and waiting time was recorded. Patient satisfaction with the service was assessed by questionnaire in September 2008. Results: Hospital referrals remained stable, but GP referrals increased from 99 to 367 (270%) and distance travelled by patients increased from a median of 3.1 km (range 0.1-12.1 km) in 2006 to 4.8 km (range 0.2-19.8 km) in 2008 (p < 0.001). Non-local GP referrals increased from 20/99 in 2006 (20%) to 198/367 in 2008 (54%). The increased workload was managed by flexible working by radiologists and two additional sonographers. Departmental waiting time increased for all patients with same-day patients waiting a median of 35 min (interquartile range 19-60 min). Ninety-one percent (79/87) of same-day patients rated the service excellent or good, but many requested better information on the waiting time. Conclusion: There is a demand from GPs for same-day US, and it is feasible in a large hospital with flexible radiology working and increased sonographic staffing. Unless adjacent hospitals offer a similar service, continuing rise in demand could overwhelm the service.

  12. Bidirectional psychoneuroimmune interactions in the early postpartum period influence risk of postpartum depression.

    Science.gov (United States)

    Corwin, Elizabeth J; Pajer, Kathleen; Paul, Sudeshna; Lowe, Nancy; Weber, Mary; McCarthy, Donna O

    2015-10-01

    More than 500,000 U.S. women develop postpartum depression (PPD) annually. Although psychosocial risks are known, the underlying biology remains unclear. Dysregulation of the immune inflammatory response and the hypothalamic-pituitary-adrenal (HPA) axis are associated with depression in other populations. While significant research on the contribution of these systems to the development of PPD has been conducted, results have been inconclusive. This is partly because few studies have focused on whether disruption in the bidirectional and dynamic interaction between the inflammatory response and the HPA axis together influence PPD. In this study, we tested the hypothesis that disruption in the inflammatory-HPA axis bidirectional relationship would increase the risk of PPD. Plasma pro- and anti-inflammatory cytokines were measured in women during the 3rd trimester of pregnancy and on Days 7 and 14, and Months 1, 2, 3, and 6 after childbirth. Saliva was collected 5 times the day preceding blood draws for determination of cortisol area under the curve (AUC) and depressive symptoms were measured using the Edinburgh Postpartum Depression Survey (EPDS). Of the 152 women who completed the EPDS, 18% were depressed according to EDPS criteria within the 6months postpartum. Cortisol AUC was higher in symptomatic women on Day 14 (p=.017). To consider the combined effects of cytokines and cortisol on predicting symptoms of PPD, a multiple logistic regression model was developed that included predictors identified in bivariate analyses to have an effect on depressive symptoms. Results indicated that family history of depression, day 14 cortisol AUC, and the day 14 IL8/IL10 ratio were significant predictors of PPD symptoms. One unit increase each in the IL8/IL10 ratio and cortisol AUC resulted in 1.50 (p=0.06) and 2.16 (p=0.02) fold increases respectively in the development of PPD. Overall, this model correctly classified 84.2% of individuals in their respective groups. Findings

  13. NASPGHAN Capsule Endoscopy Clinical Report.

    Science.gov (United States)

    Friedlander, Joel A; Liu, Quin Y; Sahn, Benjamin; Kooros, Koorosh; Walsh, Catharine M; Kramer, Robert E; Lightdale, Jenifer R; Khlevner, Julie; McOmber, Mark; Kurowski, Jacob; Giefer, Matthew J; Pall, Harpreet; Troendle, David M; Utterson, Elizabeth C; Brill, Herbert; Zacur, George M; Lirio, Richard A; Lerner, Diana G; Reynolds, Carrie; Gibbons, Troy E; Wilsey, Michael; Liacouras, Chris A; Fishman, Douglas S

    2017-03-01

    Wireless capsule endoscopy (CE) was introduced in 2000 as a less invasive method to visualize the distal small bowel in adults. Because this technology has advanced it has been adapted for use in pediatric gastroenterology. Several studies have described its clinical use, utility, and various training methods but pediatric literature regarding CE is limited. This clinical report developed by the Endoscopic and Procedures Committee of the North American Society of Pediatric Gastroenterology, Hepatology and Nutrition outlines the current literature, and describes the recommended current role, use, training, and future areas of research for CE in pediatrics.

  14. Many apples a day keep the blues away--daily experiences of negative and positive affect and food consumption in young adults.

    Science.gov (United States)

    White, Bonnie A; Horwath, Caroline C; Conner, Tamlin S

    2013-11-01

    Prior research has focused on the association between negative affect and eating behaviour, often utilizing laboratory or cross-sectional study designs. These studies have inherent limitations, and the association between positive affect and eating behaviour remains relatively unexplored. Therefore, the objective of this study was to investigate the bidirectional relationships between daily negative and positive affective experiences and food consumption in a naturalistic setting among healthy young adults. Daily diary study across 21 days (microlongitudinal, correlational design). A total of 281 young adults with a mean age of 19.9 (± 1.2) years completed an Internet-based daily diary for 21 consecutive days. Each day they reported their negative and positive affect, and their consumption of five specific foods. Hierarchical linear modelling was used to test same-day associations between daily affect and food consumption, and next-day (lagged) associations to determine directionality. Moderating effects of BMI and gender were also examined in exploratory analyses. Analyses of same-day within-person associations revealed that on days when young adults experienced greater positive affect, they reported eating more servings of fruit (p = .002) and vegetables (p positive affect the next day, suggesting that healthy foods were driving affective experiences and not vice versa. Meaningful changes in positive affect were observed with the daily consumption of approximately 7-8 servings of fruit or vegetables. Eating fruit and vegetables may promote emotional well-being among healthy young adults. © 2013 The British Psychological Society.

  15. Endoscopic findings in patients presenting with dysphagia: analysis of a national endoscopy database.

    Science.gov (United States)

    Krishnamurthy, Chaya; Hilden, Kristen; Peterson, Kathryn A; Mattek, Nora; Adler, Douglas G; Fang, John C

    2012-03-01

    Dysphagia is a common problem and an indication for upper endoscopy. There is no data on the frequency of the different endoscopic findings and whether they change according to demographics or by single versus repeat endoscopy. To determine the prevalence of endoscopic findings in patients with dysphagia and whether findings differ in regard to age, gender, ethnicity, and repeat procedure. This was a retrospective study using a national endoscopic database (CORI). A total of 30,377 patients underwent esophagogastroduodenoscopy (EGD) for dysphagia of which 4,202 patients were repeat endoscopies. Overall frequency of endoscopic findings was determined by gender, age, ethnicity, and single vs. repeat procedures. Esophageal stricture was the most common finding followed by normal, esophagitis/ulcer (EU), Schatzki ring (SR), esophageal food impaction (EFI), and suspected malignancy. Males were more likely to undergo repeat endoscopies and more likely to have stricture, EU, EFI, and suspected malignancy (P = 0.001). Patients 60 years or older had a higher prevalence of stricture, EU, SR, and suspected malignancy (P findings differs significantly by gender, age, and repeat procedure. The most common findings in descending order were stricture, normal, EU, SR, EFI, and suspected malignancy. For patients undergoing a repeat procedure, normal and EU were less common and all other abnormal findings were significantly more common.

  16. Detection of active bleeding from gastric antral vascular ectasia by capsule endoscopy

    Science.gov (United States)

    Ohira, Tetsuya; Hokama, Akira; Kinjo, Nagisa; Nakamoto, Manabu; Kobashigawa, Chiharu; Kise, Yuya; Yamashiro, Satoshi; Kinjo, Fukunori; Kuniyoshi, Yukio; Fujita, Jiro

    2013-01-01

    Gastric antral vascular ectasia (GAVE) has been recognized as one of the important causes of occult and obscure gastrointestinal bleeding. The diagnosis is typically made based on the characteristic endoscopic features, including longitudinal row of flat, reddish stripes radiating from the pylorus into the antrum that resemble the stripes on a watermelon. These appearances, however, can easily be misinterpreted as moderate to severe gastritis. Although it is believed that capsule endoscopy (CE) is not helpful for the study of the stomach with its large lumen, GAVE can be more likely to be detected at CE rather than conventional endoscopy. CE can be regarded as “physiologic” endoscopy, without the need for gastric inflation and subsequent compression of the vasculature. The blood flow of the ecstatic vessels may be diminished in an inflated stomach. Therefore, GAVE may be prominent in CE. We herein describe a case of active bleeding from GAVE detected by CE and would like to emphasize a possibility that CE can improve diagnostic yields for GAVE. PMID:23515703

  17. Advanced Therapeutic Gastrointestinal Endoscopy in Children – Today and Tomorrow

    Directory of Open Access Journals (Sweden)

    Zaheer Nabi

    2018-03-01

    Full Text Available Gastrointestinal (GI endoscopy plays an indispensable role in the diagnosis and management of various pediatric GI disorders. While the pace of development of pediatric GI endoscopy has increased over the years, it remains sluggish compared to the advancements in GI endoscopic interventions available in adults. The predominant reasons that explain this observation include lack of formal training courses in advanced pediatric GI interventions, economic constraints in establishing a pediatric endoscopy unit, and unavailability of pediatric-specific devices and accessories. However, the situation is changing and more pediatric GI specialists are now performing complex GI procedures such as endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography for various pancreatico-biliary diseases and more recently, per-oral endoscopic myotomy for achalasia cardia. Endoscopic procedures are associated with reduced morbidity and mortality compared to open surgery for GI disorders. Notable examples include chronic pancreatitis, pancreatic fluid collections, various biliary diseases, and achalasia cardia for which previously open surgery was the treatment modality of choice. A solid body of evidence supports the safety and efficacy of endoscopic management in adults. However, additions continue to be made to literature describing the pediatric population. An important consideration in children includes size of children, which in turn determines the selection of endoscopes and type of sedation that can be used for the procedure.

  18. ABOUT HYBRID BIDIRECTIONAL ASSOCIATIVE MEMORY NEURAL NETWORKS WITH DISCRETE DELAYS

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    In this paper, hybrid bidirectional associative memory neural networks with discrete delays is considered. By ingeniously importing real parameters di > 0(i = 1,2,···,n) which can be adjusted, we establish some new sufficient conditions for the dynamical characteristics of hybrid bidirectional associative memory neural networks with discrete delays by the method of variation of parameters and some analysis techniques. Our results generalize and improve the related results in [10,11]. Our work is significant...

  19. Low power design of wireless endoscopy compression/communication architecture

    Directory of Open Access Journals (Sweden)

    Zitouni Abdelkrim

    2018-05-01

    Full Text Available A wireless endoscopy capsule represents an efficient device interesting on the examination of digestive diseases. Many performance criteria’s (silicon area, dissipated power, image quality, computational time, etc. need to be deeply studied.In this paper, our interest is the optimization of the indicated criteria. The proposed methodology is based on exploring the advantages of the DCT/DWT transforms by combining them into single architecture. For arithmetic operations, the MCLA technique is used. This architecture integrates also a CABAC entropy coder that supports all binarization schemes. AMBA/I2C architecture is developed for assuring optimized communication.The comparisons of the proposed architecture with the most popular methods explained in related works show efficient results in terms dissipated power, hardware cost, and computation speed. Keywords: Wireless endoscopy capsule, DCT/DWT image compression, CABAC entropy coder, AMBA/I2C multi-bus architecture

  20. Bi-directional electrons in the near-Earth plasma sheet

    Directory of Open Access Journals (Sweden)

    K. Shiokawa

    2003-07-01

    Full Text Available We have studied the occurrence characteristics of bi-directional electron pitch angle anisotropy (enhanced flux in field-aligned directions, F^ /F|| > 1.5 at energies of 0.1–30 keV using plasma and magnetic field data from the AMPTE/IRM satellite in the near-Earth plasma sheet. The occurrence rate increases in the tailward direction from XGSM = - 9 RE to - 19 RE . The occurrence rate is also enhanced in the midnight sector, and furthermore, whenever the elevation angle of the magnetic field is large while the magnetic field intensity is small, B ~ 15 nT. From these facts, we conclude that the bi-directional electrons in the central plasma sheet are produced mainly in the vicinity of the neutral sheet and that the contribution from ionospheric electrons is minor. A high occurrence is also found after earthward high-speed ion flows, suggesting Fermi-type field-aligned electron acceleration in the neutral sheet. Occurrence characteristics of bi-directional electrons in the plasma sheet boundary layer are also discussed.Key words. Magnetospheric physics (magnetospheric configuration and dynamics; magnetotail; plasma sheet

  1. Wireless capsule endoscopy in adolescents with familial adenomatous polyposis.

    Science.gov (United States)

    Cavallo, Debora; Ballardini, Giovanni; Ferrari, Andrea; Delconte, Gabriele; Signoroni, Stefano; Sala, Paola; Chiaravalli, Stefano; Massimino, Maura; Bertario, Lucio; Vitellaro, Marco

    2016-01-01

    Guidelines for surveillance in patients with familial adenomatous polyposis (FAP) recommend mutation carriers to undergo periodic colorectal examination starting in the early teens. Performing colonoscopy in children may lead to complications. Wireless capsule endoscopy (WCE) has been introduced recently to evaluate both the upper and lower gastrointestinal tract, and seems suitable as a first screening examination for adolescents. The aim of this study was to evaluate the pros and cons of WCE. This was a retrospective review of a single institution database of adolescent patients with FAP identified through the Hereditary Colorectal Tumor Registry between 2007 and 2013. The main outcomes were identification of upper and lower gastrointestinal tract polyps, tolerance of the examination, and number and size of polyps. Of 46 adolescent patients with FAP, 14 (30.4%) patients carrying adenomatous polyposis coli gene (APC) mutation, 6 male and 8 female, age (median, range) 12 (10-17) years, body mass index 19 (13-24), underwent WCE as first screening examination. The examination was completed in 13 patients (93.3%). Wireless capsule endoscopy identified the duodenal papilla in 4 patients and colonic and rectal polyps in all 13 patients. In 7 patients, fewer than 25 polyps were identified. No complications were recorded related to the use of the video capsule. Wireless capsule endoscopy is feasible and well-tolerated as a first screening examination in adolescent patients. It cannot be used as alternative to the colonoscopy, but could improve compliance with colonoscopy, and increase early adherence to a surveillance program.

  2. Energy-efficient three-phase bidirectional converter for grid-connected storage applications

    International Nuclear Information System (INIS)

    Colmenar-Santos, Antonio; Linares-Mena, Ana-Rosa; Velázquez, Jesús Fernández; Borge-Diez, David

    2016-01-01

    Highlights: • Storage control system developed based on AC DC three phase bidirectional converter. • Bidirectional AC DC converter for storage integration into distribution grids. • Efficiencies over 98% for values over 30% of the bidirectional converter rated power. • Sensitivity analysis of the parameters set by the transmission system operator. • Low-cost option for control and integration of new grid-connected storage systems. - Abstract: Grid connected energy storage systems are expected to play an essential role in the development of Smart Grids, providing, among other benefits, ancillary services to power grids. It is therefore crucial to design and develop control and conversion systems that represent the key instrument where intelligence for decision-making is applied, in order to validate and ensure its optimal operation as part and parcel of the electrical system. The present research describes the design and development of a battery energy storage system based on an AC-DC three-phase bidirectional converter capable of operating either in charge mode to store electrical energy, or in discharge mode to supply load demands. The design is modelled with MATLAB® Simulink® environment in order to evaluate the performance during load variations. Moreover, the assessment is complemented by a global sensitivity analysis for variations in the operating parameters set by the transmission system operator. The effectiveness of the simulation is confirmed by implementing the system and carrying out grid connection tests, obtaining efficiencies over 98% for values over the 30% of the bidirectional converter rated power.

  3. Clinical trial: a randomized trial of early endoscopy, Helicobacter pylori testing and empirical therapy for the management of dyspepsia in primary care.

    Science.gov (United States)

    Duggan, A E; Elliott, C A; Miller, P; Hawkey, C J; Logan, R F A

    2009-01-01

    Early endoscopy, Helicobacter pylori eradication and empirical acid suppression are commonly used dyspepsia management strategies in primary care but have not been directly compared in a single trial. To compare endoscopy, H. pylori test and refer, H. pylori test and treat and empirical acid suppression for dyspepsia in primary care. Patients presenting to their general practitioner with dyspepsia were randomized to endoscopy, H. pylori'test and treat', H. pylori test and endoscope positives, or empirical therapy with symptoms, patient satisfaction, healthcare costs and cost effectiveness at 12 months being the outcomes. At 2 months, the proportion of patients reporting no or minimal dyspeptic symptoms ranged from 74% for those having early endoscopy to 55% for those on empirical therapy (P = 0.009), but at 1 year, there was little difference among the four strategies. Early endoscopy was associated with fewer subsequent consultations for dyspepsia (P = 0.003). 'Test and treat' resulted in fewer endoscopies overall and was most cost-effective over a range of cost assumptions. Empirical therapy resulted in the lowest initial costs, but the highest rate of subsequent endoscopy. Gastro-oesophageal cancers were found in four patients randomized to the H. pylori testing strategies. While early endoscopy offered some advantages 'Test and treat' was the most cost-effective strategy. In older patients, early endoscopy may be an appropriate strategy in view of the greater risk of malignant disease. © 2008 The Authors. Journal compilation © 2008 Blackwell Publishing Ltd.

  4. Diagnosis of chronic rhino sinusitis in patients with cystic fibrosis: correlation between anamnesis, nasal endoscopy and computed tomography

    International Nuclear Information System (INIS)

    Boari, Leticia; Castro Junior, Ney Penteado de

    2005-01-01

    The sinonasal involvement is one of the most common manifestations in cystic fibrosis. Data show a high incidence of chronic rhino sinusitis in these patients. Although it has been found radiographic opacification of the sinus in more than 90% of cases, few are symptomatic. So that, it is difficult to recognize nasossinusal disease in patients with cystic fibrosis. Questionnaire, nasal endoscopy and CT-scan are very important methods in this approach. Aim: to evaluate the diagnosis of chronic rhino sinusitis in patients with cystic fibrosis by anamnesis, nasal endoscopy and CT-scan and compare those results.Study Design: Clinical prospective. Material and method: evaluation of 34 patients - older than 6 years and with a confirmed diagnoses of cystic fibrosis - by anamnesis (questionnaire), nasal endoscopy (score Lund-Kennedy) and CT-scan (score Lund-Mackay). Results: chronic rhino sinusitis was confirmed in: 20,58% of cases by the questionnaire, 73,52% of the cases by the nasal endoscopy and in 93,54% of the cases by the CT-scan. The results showed significant differences. The correlation between nasal endoscopy score (Lund-Kennedy score) and CT-scan score (Lund-Mackay score) was statistically significant. Conclusion: the diagnosis of chronic rhino sinusitis was statistically different between the three methods. It was higher in imaging analysis and lower in questionnaire. The nasal endoscopy is an excellent method to evaluate nasossinusal disease in cystic fibrosis. (author)

  5. Role of Endoscopy in Diagnosis and Management of Pediatric Eosinophilic Esophagitis.

    Science.gov (United States)

    Muir, Amanda B; Merves, Jamie; Liacouras, Chris A

    2016-01-01

    Eosinophilic esophagitis (EoE) is a chronic allergic (immune-mediated) disease that leads to esophageal dysfunction and feeding disorders in children. Foods, and possibly environmental triggers, cause an inflammatory response in the esophagus, leading to esophageal inflammation, eosinophilic infiltration, and esophageal dysmotility, which may progress to dysphagia, food impaction, and esophageal stricture. Endoscopy with biopsy and histologic evaluation is currently the only method to diagnose EoE. Once diagnosed with EoE, children undergo follow-up endoscopy after therapy initiation and adjustments to ensure remission. Furthermore, children with food impactions or strictures may require endoscopic intervention such as foreign body removal and/or esophageal dilation. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Exact bidirectional X -wave solutions in fiber Bragg gratings

    Science.gov (United States)

    Efremidis, Nikolaos K.; Nye, Nicholas S.; Christodoulides, Demetrios N.

    2017-10-01

    We find exact solutions describing bidirectional pulses propagating in fiber Bragg gratings. They are derived by solving the coupled-mode theory equations and are expressed in terms of products of modified Bessel functions with algebraic functions. Depending on the values of the two free parameters, the general bidirectional X -wave solution can also take the form of a unidirectional pulse. We analyze the symmetries and the asymptotic properties of the solutions and also discuss additional waveforms that are obtained by interference of more than one solution. Depending on their parameters, such pulses can create a sharp focus with high contrast.

  7. The number of injected same-day preschool vaccines relates to preadolescent needle fear and HPV uptake.

    Science.gov (United States)

    Baxter, Amy L; Cohen, Lindsey L; Burton, Mark; Mohammed, Anaam; Lawson, M Louise

    2017-07-24

    Fear of needles develops at approximately five years of age, and decreases compliance with healthcare. We sought to examine the relationship of preschool vaccine history, parent and preadolescent needle fear, and subsequent compliance with optional vaccines. As part of a private practice randomized controlled trial, parents and 10-12year olds rated needle anxiety on a 100mm visual analog scale. This follow-up cohort study compared their needle anxiety to previous vaccination records, including number of vaccinations between ages four and six years (total and same-day maximum), and subsequent initiation of the HPV vaccine through age 13. Of the 120 preadolescents enrolled between 4.28.09 and 1.19.2010, 117 received preschool vaccinations between ages four and six years. The likelihood of being in the upper quartile of fear (VAS≥83) five years later increased with each additional same-day injection (OR=3.108, p=0.0100 95%CI=1.311, 7.367), but was not related to total lifetime or total four-to-six year injections. Only 12.5% (15) of parents reported anxiety about their preadolescents' vaccines (VAS>50). Parent and child anxiety was weakly correlated (r=0.15). Eight children in the upper fear quartile began their HPV series (26.67%) compared to 14 in the lower quartile (48.28% VASfear needles five years later. Preadolescent needle fear was a stronger predictor than parent vaccine anxiety of subsequent HPV vaccine uptake. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Improving safety of personnel exposed to disinfectants by introducing an Endoscopy Quality Assurance Program

    OpenAIRE

    Ahmed Gado; Basel Ebeid; Aida Abdelmohsen; Anthony Axon

    2014-01-01

    Background: Chemical disinfection is the most commonly used method in gastrointestinal endoscopy reprocessing. The main problem with chemical disinfection is that it is potentially harmful to humans. Risk assessment of employees using toxic substances is recommended and the control of exposure to these substances is required. In 2003, an endoscopy quality-assurance program was instituted in a secondary care governmental hospital in Egypt. Aim: The aim of the study was to assess the risk to...

  9. Feasibility of same-day identification of members of the family Vibrionaceae by the API 20E system.

    OpenAIRE

    Overman, T L; Overley, J K

    1986-01-01

    Sixty isolates, comprising nine species of the family Vibrionaceae, were tested with the API 20E 5-h same-day procedure (Analytab Products, Plainview, N.Y.). Included were 27 Aeromonas hydrophila isolates, 10 Aeromonas sobria isolates, 7 Aeromonas caviae isolates, 3 Plesiomonas shigelloides isolates, 3 Vibrio alginolyticus isolates, 3 Vibrio cholerae isolates, 1 Vibrio fluvialis isolate, 5 Vibrio parahaemolyticus isolates, and 1 Vibrio vulnificus isolate. The 5-h profile numbers were specific...

  10. Outcome of endoscopy-assisted microscopic extended transsphenoidal surgery for suprasellar craniopharyngiomas

    Directory of Open Access Journals (Sweden)

    Hidetoshi eIkeda

    2012-02-01

    Full Text Available Objectives. Craniopharyngiomas are difficult to treat. The extended transsphenoidal approach has recently been described in several small series. We describe the usefulness of microscopy-assisted angled endoscopy for visualizing vital structures such as tumor attachment or tumor invasion to the pituitary stalk to achieve confident radical tumor removal.Design and Participants. Between 2006 and 2010, 15 patients underwent the microscopy-assisted extended transsphenoidal approach for resection of entirely suprasellar craniopharyngiomas. 14 patients had the transinfundibular type, and one had the transinfundibular type with the extension to third ventricle. We observed color change within the pituitary stalk by endoscopy. The pituitary stalk was cut intentionally in ten patients, because of suspected tumor invasion surrounding the stalk. Main Outcome Measures and Results. Total removal was accomplished in nine patients. Pathological specimens from the pituitary stalk showed tumor invasion spreading over the surface of the pituitary stalk, shown by a discolored pituitary stalk, and this was essential for confident radical tumor removal. Even after stalk resection, postoperative DI was minimal when a bright signal on T1 in the posterior lobe was not confirmed on preoperative magnetic resonance imaging. Conclusion. Confident radical tumor removal is possible with the introduction of the endoscopy-assisted microscopic extended transsphenoidal approach.

  11. Analysis of bi-directional piezoelectric-based converters for zero-voltage switching operation

    DEFF Research Database (Denmark)

    Ekhtiari, Marzieh; Zhang, Zhe; Andersen, Michael A. E.

    2016-01-01

    This paper deals with a thorough analysis of zerovoltage switching especially for bi-directional, inductorless, piezoelectric transformer-based switch-mode power supplies with a half-bridge topology. Practically, obtaining zero-voltage switching for all of the switches in a bi-directional piezoel......This paper deals with a thorough analysis of zerovoltage switching especially for bi-directional, inductorless, piezoelectric transformer-based switch-mode power supplies with a half-bridge topology. Practically, obtaining zero-voltage switching for all of the switches in a bi......-directional piezoelectric power converter is a difficult task. However, the analysis in this work will be convenient for overcoming this challenge. The analysis defines the zero-voltage region indicating the operating points whether or not soft switching can be met over the switching frequency and load range. For the first...... time, a comprehensive analysis is provided, which can be used as a design guideline for applying control techniques in order to drive switches in piezoelectric transformer-based converters. This study further conveys the proposed method to the region where all the switches can obtain soft switching...

  12. Two-Dimensional High Definition Versus Three-Dimensional Endoscopy in Endonasal Skull Base Surgery: A Comparative Preclinical Study.

    Science.gov (United States)

    Rampinelli, Vittorio; Doglietto, Francesco; Mattavelli, Davide; Qiu, Jimmy; Raffetti, Elena; Schreiber, Alberto; Villaret, Andrea Bolzoni; Kucharczyk, Walter; Donato, Francesco; Fontanella, Marco Maria; Nicolai, Piero

    2017-09-01

    Three-dimensional (3D) endoscopy has been recently introduced in endonasal skull base surgery. Only a relatively limited number of studies have compared it to 2-dimensional, high definition technology. The objective was to compare, in a preclinical setting for endonasal endoscopic surgery, the surgical maneuverability of 2-dimensional, high definition and 3D endoscopy. A group of 68 volunteers, novice and experienced surgeons, were asked to perform 2 tasks, namely simulating grasping and dissection surgical maneuvers, in a model of the nasal cavities. Time to complete the tasks was recorded. A questionnaire to investigate subjective feelings during tasks was filled by each participant. In 25 subjects, the surgeons' movements were continuously tracked by a magnetic-based neuronavigator coupled with dedicated software (ApproachViewer, part of GTx-UHN) and the recorded trajectories were analyzed by comparing jitter, sum of square differences, and funnel index. Total execution time was significantly lower with 3D technology (P < 0.05) in beginners and experts. Questionnaires showed that beginners preferred 3D endoscopy more frequently than experts. A minority (14%) of beginners experienced discomfort with 3D endoscopy. Analysis of jitter showed a trend toward increased effectiveness of surgical maneuvers with 3D endoscopy. Sum of square differences and funnel index analyses documented better values with 3D endoscopy in experts. In a preclinical setting for endonasal skull base surgery, 3D technology appears to confer an advantage in terms of time of execution and precision of surgical maneuvers. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Effect of listening to Vedic chants and Indian classical instrumental music on patients undergoing upper gastrointestinal endoscopy: A randomized control trial.

    Science.gov (United States)

    Padam, Anita; Sharma, Neetu; Sastri, O S K S; Mahajan, Shivani; Sharma, Rajesh; Sharma, Deepak

    2017-01-01

    A high level of preoperative anxiety is common among patients undergoing medical and surgical procedures. Anxiety impacts of gastroenterological procedures on psychological and physiological responses are worth consideration. To analyze the effect of listening to Vedic chants and Indian classical instrumental music on anxiety levels and on blood pressure (BP), heart rate (HR), and oxygen saturation in patients undergoing upper gastrointestinal (GI) endoscopy. A prospective, randomized controlled trial was done on 199 patients undergoing upper GI endoscopy. On arrival, their anxiety levels were assessed using state and trait scores and various physiological parameters such as HR, BP, and SpO 2 . Patients were randomly divided into three groups: Group I of 67 patients who were made to listen prerecorded Vedic chants for 10 min, Group II consisting of 66 patients who listened to Indian classical instrumental music for 10 min, and Group III of 66 controls who remained seated for same period in the same environment. Thereafter, their anxiety state scores and physiological parameters were reassessed. A significant reduction in anxiety state scores was observed in the patients in Group I (from 40.4 ± 8.9 to 38.5 ± 10.7; P classical instrumental music has beneficial effects on alleviating anxiety levels induced by apprehension of invasive procedures and can be of therapeutic use.

  14. Bidirectional communication in an HF hybrid organic/solution-processed metal-oxide RFID tag

    NARCIS (Netherlands)

    Myny, K.; Rockelé, M.; Chasin, A.; Pham, D.V.; Steiger, J.; Botnaras, S.; Weber, D.; Herold, B.; Ficker, J.; Van Putten, B.D.; Gelinck, G.H.; Genoe, J.; Dehaene, W.; Heremans, P.

    2014-01-01

    A bidirectional communication protocol allows radio-frequency identification (RFID) tags to have readout of multiple tags in the RF field without collision of data. In this paper, we realized bidirectional communication between a reader system and thin-film RFID tag by introducing a novel protocol

  15. Endoscopic non-technical skills team training: The next step in quality assurance of endoscopy training

    Science.gov (United States)

    Matharoo, Manmeet; Haycock, Adam; Sevdalis, Nick; Thomas-Gibson, Siwan

    2014-01-01

    AIM: To investigate whether novel, non-technical skills training for Bowel Cancer Screening (BCS) endoscopy teams enhanced patient safety knowledge and attitudes. METHODS: A novel endoscopy team training intervention for BCS teams was developed and evaluated as a pre-post intervention study. Four multi-disciplinary BCS teams constituting BCS endoscopist(s), specialist screening practitioners, endoscopy nurses and administrative staff (A) from English BCS training centres participated. No patients were involved in this study. Expert multidisciplinary faculty delivered a single day’s training utilising real clinical examples. Pre and post-course evaluation comprised participants’ patient safety awareness, attitudes, and knowledge. Global course evaluations were also collected. RESULTS: Twenty-three participants attended and their patient safety knowledge improved significantly from 43%-55% (P ≤ 0.001) following the training intervention. 12/41 (29%) of the safety attitudes items significantly improved in the areas of perceived patient safety knowledge and awareness. The remaining safety attitude items: perceived influence on patient safety, attitudes towards error management, error management actions and personal views following an error were unchanged following training. Both qualitative and quantitative global course evaluations were positive: 21/23 (91%) participants strongly agreed/agreed that they were satisfied with the course. Qualitative evaluation included mandating such training for endoscopy teams outside BCS and incorporating team training within wider endoscopy training. Limitations of the study include no measure of increased patient safety in clinical practice following training. CONCLUSION: A novel comprehensive training package addressing patient safety, non-technical skills and adverse event analysis was successful in improving multi-disciplinary teams’ knowledge and safety attitudes. PMID:25516665

  16. Preoperative Planning Using 3D Reconstructions and Virtual Endoscopy for Location of the Frontal Sinus

    Directory of Open Access Journals (Sweden)

    Abreu, João Paulo Saraiva

    2011-01-01

    Full Text Available Introduction: Computed tomography (TC generated tridimensional (3D reconstructions allow the observation of cavities and anatomic structures of our body with detail. In our specialty there have been attempts to carry out virtual endoscopies and laryngoscopies. However, such application has been practically abandoned due to its complexity and need for computers with high power of graphic processing. Objective: To demonstrate the production of 3D reconstructions from CTs of patients in personal computers, with a free specific program and compare them to the surgery actual endoscopic images. Method: Prospective study in which the CTs proper files of 10 patients were reconstructed with the program Intage Realia, version 2009, 0, 0, 702 (KGT Inc., Japan. The reconstructions were carried out before the surgeries and a virtual endoscopy was made to assess the recess and frontal sinus region. After this study, the surgery was digitally performed and stored. The actual endoscopic images of the recess and frontal sinus region were compared to the virtual images. Results: The 3D reconstruction and virtual endoscopy were made in 10 patients submitted to the surgery. The virtual images had a large resemblance with the actual surgical images. Conclusion: With relatively simple tools and personal computer, we demonstrated the possibility to generate 3D reconstructions and virtual endoscopies. The preoperative knowledge of the frontal sinus natural draining path location may generate benefits during the performance of surgeries. However, more studies must be developed for the evaluation of the real roles of such 3D reconstructions and virtual endoscopies.

  17. On Training Bi-directional Neural Network Language Model with Noise Contrastive Estimation

    OpenAIRE

    He, Tianxing; Zhang, Yu; Droppo, Jasha; Yu, Kai

    2016-01-01

    We propose to train bi-directional neural network language model(NNLM) with noise contrastive estimation(NCE). Experiments are conducted on a rescore task on the PTB data set. It is shown that NCE-trained bi-directional NNLM outperformed the one trained by conventional maximum likelihood training. But still(regretfully), it did not out-perform the baseline uni-directional NNLM.

  18. High definition versus standard definition white light endoscopy for detecting dysplasia in patients with Barrett's esophagus.

    Science.gov (United States)

    Sami, S S; Subramanian, V; Butt, W M; Bejkar, G; Coleman, J; Mannath, J; Ragunath, K

    2015-01-01

    High-definition endoscopy systems provide superior image resolution. The aim of this study was to assess the utility of high definition compared with standard definition endoscopy system for detecting dysplastic lesions in patients with Barrett's esophagus. A retrospective cohort study of patients with non-dysplastic Barrett's esophagus undergoing routine surveillance was performed. Data were retrieved from the central hospital electronic database. Procedures performed for non-surveillance indications, Barrett's esophagus Prague C0M1 classification with no specialized intestinal metaplasia on histology, patients diagnosed with any dysplasia or cancer on index endoscopy, and procedures using advanced imaging techniques were excluded. Logistic regression models were constructed to estimate adjusted odds ratios and 95% confidence intervals comparing outcomes with standard definition and high-definition systems. The high definition was superior to standard definition system in targeted detection of all dysplastic lesions (odds ratio 3.27, 95% confidence interval 1.27-8.40) as well as overall dysplasia detected on both random and target biopsies (odds ratio 2.36, 95% confidence interval 1.50-3.72). More non-dysplastic lesions were detected with the high-definition system (odds ratio 1.16, 95% confidence interval 1.01-1.33). There was no difference between high definition and standard definition endoscopy in the overall (random and target) high-grade dysplasia or cancers detected (odds ratio 0.93, 95% confidence interval 0.83-1.04). Trainee endoscopists, number of biopsies taken, and male sex were all significantly associated with a higher yield for dysplastic lesions. The use of the high-definition endoscopy system is associated with better targeted detection of any dysplasia during routine Barrett's esophagus surveillance. However, high-definition endoscopy cannot replace random biopsies at present time. © 2014 International Society for Diseases of the Esophagus.

  19. Bidirectional Thermo-Mechanical Properties of Foam Core Materials Using DIC

    DEFF Research Database (Denmark)

    Taher, Siavash Talebi; Thomsen, Ole Thybo; M Dulieu-Barton, Janice

    2011-01-01

    mechanical properties at room and at elevated temperatures. The MAF enables the realization of pure compression or high compression to shear bidirectional loading conditions that is not possible with conventional Arcan fixtures. The MAF is attached to a standard universal test machine equiped...... with an environmental chamber using specially designed grips that allow the specimen to rotate, and hence reduces paristic effects due to misalignment. The objective is to measure the unidirectional and bidirectional mechanical properties of PVC foam materials at elevated tempreature using digital image correlation...

  20. Prevalence of gastroduodenal ulcers/erosions in patients taking low-dose aspirin with either 15 mg/day of lansoprazole or 40 mg/day of famotidine: the OITA-GF study 2.

    Science.gov (United States)

    Tamura, Akira; Murakami, Kazunari; Kadota, Junichi

    2013-03-26

    The preventive effects of histamine 2 receptor antagonists vs. proton pump inhibitors on low-dose aspirin (LDA)-related gastroduodenal mucosal injury have not been fully investigated. We conducted a cross-sectional study to compare the prevalence of gastroduodenal ulcers or erosions in patients taking LDA with either 40 mg/day of famotidine or 15 mg/day of lansoprazole for at least three months. Of 84 eligible patients, two taking 40 mg/day of famotidine and four taking 15 mg/day of lansoprazole refused to undergo upper gastrointestinal endoscopy. Ultimately, we performed upper gastrointestinal endoscopy in 78 patients taking either 40 mg/day of famotidine (group F, n = 31) or 15 mg/day of lansoprazole (group L, n = 47). The prevalence of gastroduodenal ulcers or erosions and the magnitude of gastric mucosal injury evaluated using modified Lanza scores were compared between the two groups. No patients in either group had gastroduodenal ulcers. Gastroduodenal erosions were more prevalent in group F than in group L (48.4% vs. 17.0%, p = 0.005). The modified Lanza scores (mean ± SD) were significantly higher in group F than in group L (0.9 ± 1.3 vs. 0.3 ± 0.7, p = 0.007). A multivariate logistic regression analysis showed that the use of lansoprazole was negatively associated with gastroduodenal erosions. This study suggests that 15 mg/day of lansoprazole may be more effective in preventing the development of LDA-related gastroduodenal erosions than 40 mg/day of famotidine. The preventive effects of these two regimens on the development of LDA-related gastroduodenal ulcers require further investigation.

  1. Therapeutic Endoscopy for the Control of Nonvariceal Upper Gastrointestinal Bleeding in Children: A Case Series.

    Science.gov (United States)

    Banc-Husu, Anna M; Ahmad, Nuzhat A; Chandrasekhara, Vinay; Ginsberg, Gregory G; Jaffe, David L; Kochman, Michael L; Rajala, Michael W; Mamula, Petar

    2017-04-01

    Gastrointestinal bleeding is one of the most common indications for urgent endoscopy in the pediatric setting. The majority of these procedures are performed for control of variceal bleeding, with few performed for nonvariceal upper gastrointestinal (NVUGI) bleeding. The data on therapeutic endoscopy for NVUGI are sparse. The aims of our study were to review our experience with NVUGI bleeding, describe technical aspects and outcomes of therapeutic endoscopy, and determine gastroenterology fellows' training opportunities according to the national training guidelines. We performed a retrospective review of endoscopy database (Endoworks, Olympus Inc, Center Valley, PA) from January 2009 to December 2014. The search used the following keywords: bleeding, hematemesis, melena, injection, epinephrine, cautery, clip, and argon plasma coagulation. The collected data included demographics, description of bleeding lesion and medical/endoscopic therapy, rate of rebleeding, relevant laboratories, physical examination, and need for transfusion and surgery. The study was approved by the institutional review board. During the study period 12,737 upper endoscopies (esophagogastroduodenoscopies) were performed. A total of 15 patients underwent 17 esophagogastroduodenoscopies that required therapeutic intervention to control bleeding (1:750 procedures). The mean ± standard deviation (median) age of patients who required endoscopic intervention was 11.6 ± 6.0 years (14.0 years). Seven out of 17 patients received dual therapy to control the bleeding lesions. All but 3 patients received medical therapy with intravenous proton pump inhibitor, and 3 received octreotide infusions. Six of the patients experienced rebleeding (40%), with 4 out of 6 initially only receiving single modality therapy. Two of these patients eventually required surgical intervention to control bleeding and both patients presented with bleeding duodenal ulcers. There were no cases of aspiration

  2. Three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT: applications and limitations

    International Nuclear Information System (INIS)

    Kim, Su Yeon; Choi, Sun Seob; Kang, Myung Jin; Shin, Tae Beom; Lee, Ki Nam; Kang, Myung Koo

    2005-01-01

    This study was conducted to know the applications and limitations of three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT. This study examined 25 patients who underwent temporal bone CT using a 16-row detector CT as a result of hearing problems or trauma. The axial CT scan of the temporal bone was performed with a 0.6 mm collimation, and a reconstruction was carried out with a U70u sharp of kernel value, a 1 mm thickness and 0.5-1.0 mm increments. After observing the ossicles in the axial and coronal images, virtual endoscopy was performed using a three dimensional volume rendering technique with a threshold value of-500 HU. The intra-operative otoendoscopy was performed in 12 ears, and was compared with the virtual endoscopy findings. Virtual endoscopy of the 29 ears without hearing problems demonstrated hypoplastic or an incomplete depiction of the stapes superstructures in 25 ears and a normal depiction in 4 ears. Virtual endoscopy of 21 ears with hearing problems demonstrated no ossicles in 1 ears, no malleus in 3 ears, a malleoincudal subluxation in 6 ears, a dysplastic incus in 5 ears, an incudostapedial subluxation in 9 ears, dysplastic stapes in 2 ears, a hypoplastic or incomplete depiction of the stapes in 16 ears and no stapes in 1 ears. In contrast to the intra-operative otoendoscopy, 8 out of 12 ears showed a hypoplastic or deformed stapes in the virtual endoscopy. Volume rendering virtual endoscopy using a multi-row detector CT is an excellent method for evaluation the ossicles in three dimension, even thought the partial volume effect for the stapes superstructures needs to be considered

  3. Endoscopy and antiplatelet agents. European Society of Gastrointestinal Endoscopy (ESGE) Guideline.

    Science.gov (United States)

    Boustière, C; Veitch, A; Vanbiervliet, G; Bulois, P; Deprez, P; Laquiere, A; Laugier, R; Lesur, G; Mosler, P; Nalet, B; Napoleon, B; Rembacken, B; Ajzenberg, N; Collet, J P; Baron, T; Dumonceau, J-M

    2011-05-01

    With the increasing use of antiplatelet agents (APA), their management during the periendoscopic period has become a more common and more difficult problem. The increase in use is due to the availability of new drugs and the widespread use of drug-eluting coronary stents. Acute coronary syndromes can occur when APA therapy is withheld for noncardiovascular interventions. Guidelines about APA management during the periendoscopic period are traditionally based on assessments of the procedure-related risk of bleeding and the risk of thrombosis if APA are stopped. New data allow better assessment of these risks, of the necessary duration of APA discontinuation before endoscopy, of the use of alternative procedures (mostly for endoscopic retrograde cholangiopancreatography [ERCP]), and of endoscopic methods that can be used to prevent bleeding (following colonic polypectomy). This guideline makes graded, evidence-based, recommendations for the management of APA for all currently performed endoscopic procedures. A short summary and two tables are included for quick reference. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism.

    Science.gov (United States)

    Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S

    2013-09-01

    In a previous study, we proposed that corneal topography performed 30-40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. 10/0 nylon interrupted sutures were placed, to secure the graft-host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30-40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4-6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty.

  5. Evaluation of capsule endoscopy to detect mucosal lesions associated with gastrointestinal bleeding in dogs.

    Science.gov (United States)

    Davignon, D L; Lee, A C Y; Johnston, A N; Bowman, D D; Simpson, K W

    2016-03-01

    The objective of this study was to examine the utility of capsule endoscopy to detect mucosal abnormalities in dogs with gastrointestinal haemorrhage. Capsules were administered to 2 healthy controls and 8 patients with gastrointestinal haemorrhage. Images were evaluated for quality, gastric emptying time, small intestinal transit time and presence of lesions. There were no adverse effects of capsule endoscopy in dogs weighing from 7·7 to 58 kg. The capsule traversed the entire gastrointestinal tract in 5 of 8 patients, with high quality images obtained in the stomach and small intestine. Gastric emptying time and small intestinal transit time ranged from 1 to 270 and 15 to 180 minutes, respectively. In 3 of 8 patients, the capsule remained in the stomach despite pro-kinetics. Gastric lesions included mild haemorrhage and pinpoint erosion (4 of 8), a mass (1) and thickened bleeding pyloric mucosa (2). Two of 3 dogs with capsule retention had gastric lesions. Intestinal lesions included a healing duodenal ulcer, abnormal villi, ileal ulceration and colonic bleeding. Lesions identified by capsule endoscopy were considered a significant source of haemorrhage in 4 of 7 dogs with active bleeding. The relevance of pinpoint gastric mucosal erosions to blood loss is unclear. Capsule endoscopy can enable the non-invasive detection of gastric and small intestinal mucosal lesions in dogs presenting for evaluation of gastrointestinal bleeding. © 2016 British Small Animal Veterinary Association.

  6. Self-expandable metal stents for obstructing colonic and extracolonic cancer: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    van Hooft, Jeanin E.; van Halsema, Emo E.; Vanbiervliet, Geoffroy; Beets-Tan, Regina G. H.; Dewitt, John M.; Donnellan, Fergal; Dumonceau, Jean-Marc; Glynne-Jones, Robert G. T.; Hassan, Cesare; Jiménez-Perez, Javier; Meisner, Søren; Muthusamy, V. Raman; Parker, Michael C.; Regimbeau, Jean-Marc; Sabbagh, Charles; Sagar, Jayesh; Tanis, Pieter J.; Vandervoort, Jo; Webster, George J.; Manes, Gianpiero; Barthet, Marc A.; Repici, Alessandro

    2014-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). This Guideline was also reviewed and endorsed by the Governing Board of the American Society for Gastrointestinal Endoscopy (ASGE). The Grading of Recommendations Assessment, Development, and

  7. Self-Expandable Metal Stents for Obstructing Colonic and Extracolonic Cancer: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    van Hooft, J. E.; van Halsema, E. E.; Vanbiervliet, G.; Beets-Tan, R. G. H.; DeWitt, J. M.; Donnellan, F.; Dumonceau, J. M.; Glynne-Jones, R. G. T.; Hassan, C.; Jimenez-Perez, J.; Meisner, S.; Muthusamy, V. Raman; Parker, M. C.; Regimbeau, J. M.; Sabbagh, C.; Sagar, J.; Tanis, P. J.; Vandervoort, J.; Webster, G. J.; Manes, G.; Barthet, M. A.; Repici, A.

    2014-01-01

    This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). This Guideline was also reviewed and endorsed by the Governing Board of the American Society for Gastrointestinal Endoscopy (ASGE). The Grading of Recommendations Assessment, Development, and

  8. Implantable neurotechnologies: bidirectional neural interfaces--applications and VLSI circuit implementations.

    Science.gov (United States)

    Greenwald, Elliot; Masters, Matthew R; Thakor, Nitish V

    2016-01-01

    A bidirectional neural interface is a device that transfers information into and out of the nervous system. This class of devices has potential to improve treatment and therapy in several patient populations. Progress in very large-scale integration has advanced the design of complex integrated circuits. System-on-chip devices are capable of recording neural electrical activity and altering natural activity with electrical stimulation. Often, these devices include wireless powering and telemetry functions. This review presents the state of the art of bidirectional circuits as applied to neuroprosthetic, neurorepair, and neurotherapeutic systems.

  9. A Novel PPFHB Bidirectional DC-DC Converter for Supercapacitor Application

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael Andreas E.

    2009-01-01

    This paper presents a novel bidirectional DC-DC converter for the supercapacitor application. In the proposed converter, push-pull forward with half bridge (PPFHB) voltage doubler structure is used to reduce the number of the power switches and get higher voltage gain. Based on phase-shift modula......This paper presents a novel bidirectional DC-DC converter for the supercapacitor application. In the proposed converter, push-pull forward with half bridge (PPFHB) voltage doubler structure is used to reduce the number of the power switches and get higher voltage gain. Based on phase...

  10. Bidirectional optimization of the melting spinning process.

    Science.gov (United States)

    Liang, Xiao; Ding, Yongsheng; Wang, Zidong; Hao, Kuangrong; Hone, Kate; Wang, Huaping

    2014-02-01

    A bidirectional optimizing approach for the melting spinning process based on an immune-enhanced neural network is proposed. The proposed bidirectional model can not only reveal the internal nonlinear relationship between the process configuration and the quality indices of the fibers as final product, but also provide a tool for engineers to develop new fiber products with expected quality specifications. A neural network is taken as the basis for the bidirectional model, and an immune component is introduced to enlarge the searching scope of the solution field so that the neural network has a larger possibility to find the appropriate and reasonable solution, and the error of prediction can therefore be eliminated. The proposed intelligent model can also help to determine what kind of process configuration should be made in order to produce satisfactory fiber products. To make the proposed model practical to the manufacturing, a software platform is developed. Simulation results show that the proposed model can eliminate the approximation error raised by the neural network-based optimizing model, which is due to the extension of focusing scope by the artificial immune mechanism. Meanwhile, the proposed model with the corresponding software can conduct optimization in two directions, namely, the process optimization and category development, and the corresponding results outperform those with an ordinary neural network-based intelligent model. It is also proved that the proposed model has the potential to act as a valuable tool from which the engineers and decision makers of the spinning process could benefit.

  11. Bidirectional ventricular tachycardia of unusual etiology

    Directory of Open Access Journals (Sweden)

    Praloy Chakraborty

    2015-11-01

    Full Text Available Bidirectional ventricular tachycardia (BDVT is a rare form of ventricular arrhythmia, characterized by changing QRS axis of 180 degrees. Digitalis toxicity is considered as commonest cause of BDVT; other causes include aconite toxicity, myocarditis, myocardial infarction, metastatic cardiac tumour and cardiac channelopathies. We describe a case of BDVT in a patient with Anderson-Tawil syndrome.

  12. Bi-directional interhemispheric inhibition during unimanual sustained contractions

    Directory of Open Access Journals (Sweden)

    Ni Zhen

    2009-04-01

    Full Text Available Abstract Background The interaction between homologous muscle representations in the right and left primary motor cortex was studied using a paired-pulse transcranial magnetic stimulation (TMS protocol known to evoke interhemispheric inhibition (IHI. The timecourse and magnitude of IHI was studied in fifteen healthy right-handed adults at several interstimulus intervals between the conditioning stimulus and test stimulus (6, 8, 10, 12, 30, 40, 50 ms. IHI was studied in the motor dominant to non-dominant direction and vice versa while the right or left hand was at rest, performing isometric contraction of the first dorsal interosseous (FDI muscle, and isometric contraction of the FDI muscle in the context of holding a pen. Results Compared with rest, IHI was reduced at all ISIs during contraction of either type (with or without the context of pen. IHI was reduced bi-directionally without evidence of hemispheric dominance. Further, contraction of the hand contralateral to the conditioning and test pulse yielded similar reductions in IHI. Conclusion These data provide evidence for bi-directional reduction of IHI during unimanual contractions. During unimanual, sustained contractions of the hand, the contralateral and ipsilateral motor cortices demonstrate reduced inhibition. The data suggest that unimanual movement decreases inhibition bi-directionally across motor hemispheres and offer one explanation for the observation of ipsilateral M1 activity during hand movements.

  13. Computerisation of endoscopy reports using standard reports and text blocks

    NARCIS (Netherlands)

    Groenen, M. J. M.; Kuipers, E. J.; van Berge Henegouwen, G. P.; Fockens, P.; Ouwendijk, R. J. Th

    2006-01-01

    BACKGROUND: The widespread use of gastrointestinal endoscopy for diagnosis and treatment requires effective, standardised report systems. This need is further increased by the limited storage of images, and by the need for structured databases for surveillance and epidemiology. We therefore aimed

  14. Upper gastrointestinal diseases in patients for endoscopy in South ...

    African Journals Online (AJOL)

    The most common endoscopy finding was gastritis (40.2%), followed by normal examination (15.2%), oesophageal cancer (13.6%), gastric ulcer (7.6%) and gastric cancer (7.1%). Patients older than 40 years (n=110) had significant findings including gastritis (50.9%), oesophageal cancer (22.7%) and gastric cancer ...

  15. Hybrid artificial bee colony algorithm for parameter optimization of five-parameter bidirectional reflectance distribution function model.

    Science.gov (United States)

    Wang, Qianqian; Zhao, Jing; Gong, Yong; Hao, Qun; Peng, Zhong

    2017-11-20

    A hybrid artificial bee colony (ABC) algorithm inspired by the best-so-far solution and bacterial chemotaxis was introduced to optimize the parameters of the five-parameter bidirectional reflectance distribution function (BRDF) model. To verify the performance of the hybrid ABC algorithm, we measured BRDF of three kinds of samples and simulated the undetermined parameters of the five-parameter BRDF model using the hybrid ABC algorithm and the genetic algorithm, respectively. The experimental results demonstrate that the hybrid ABC algorithm outperforms the genetic algorithm in convergence speed, accuracy, and time efficiency under the same conditions.

  16. Family of multiport bidirectional DC-DC converters

    NARCIS (Netherlands)

    Tao, H.; Kotsopoulos, A.; Duarte, J.L.; Hendrix, M.A.M.

    2006-01-01

    Multiport DC-DC converters are of potential interest in applications such as generation systems utilising multiple sustainable energy sources. A family of multiport bidirectional DC-DC converters derived from a general topology is presented. The topology shows a combination of DC-link and magnetic

  17. A score card for upper GI endoscopy: Evaluation of interobserver variability in examiners with various levels of experience.

    Science.gov (United States)

    Neumann, M; Friedl, S; Meining, A; Egger, K; Heldwein, W; Rey, J F; Hochberger, J; Classen, M; Hohenberger, W; Rösch, T

    2002-10-01

    In most European countries, training in GI endoscopy has largely been based on hands-on acquisition of experience in patients rather than on a structured training programme. With the development of training models systematic hands-on training in a variety of diagnostic and therapeutic endoscopy techniques was achieved. Little, however, is known about methods of objectively assessing trainees' performance. We therefore developed an assessment 'score card' for upper GI endoscopy and tested it in endoscopists with various levels of experience. The aim of the study was therefore to assess interobserver variations in the evaluation of trainees. On the basis of textbook and expert opinions a consensus group of eight experienced endoscopists developed a score card for diagnostic upper GI endoscopy with biopsy. The score card includes an assessment of the single steps of the procedure as well as of the times needed to complete each step. This score card was then evaluated in a further conference including ten experts who blindly assessed videotapes of 15 endoscopists performing upper GI endoscopy in a training bio-simulation model (the 'Erlangen Endo-Trainer'). On the basis of their previous experience (i. e. the number of endoscopies performed) these 15 endoscopists were classified into four groups: very experienced, experienced, having some experience and inexperienced. Interobserver variability (IOV) was tested for the various score card parameters (Kendall's rank-correlation coefficient 0.0-0.5 poor, 0.5-1.0 good agreement). In addition, the correlation between the score card assessment and the examiners' experience levels was analysed. Despite poor IOV results for all the parameters tested (Kendall coefficient account (correlation coefficient 0.59-0.89, p < 0.05). The score card parameters were suitable for differentiating between the four groups of examiners with different levels of endoscopic experience. As expected with scores involving subjective assessment of

  18. Stray energy transfer during endoscopy.

    Science.gov (United States)

    Jones, Edward L; Madani, Amin; Overbey, Douglas M; Kiourti, Asimina; Bojja-Venkatakrishnan, Satheesh; Mikami, Dean J; Hazey, Jeffrey W; Arcomano, Todd R; Robinson, Thomas N

    2017-10-01

    Endoscopy is the standard tool for the evaluation and treatment of gastrointestinal disorders. While the risk of complication is low, the use of energy devices can increase complications by 100-fold. The mechanism of increased injury and presence of stray energy is unknown. The purpose of the study was to determine if stray energy transfer occurs during endoscopy and if so, to define strategies to minimize the risk of energy complications. A gastroscope was introduced into the stomach of an anesthetized pig. A monopolar generator delivered energy for 5 s to a snare without contacting tissue or the endoscope itself. The endoscope tip orientation, energy device type, power level, energy mode, and generator type were varied to mimic in vivo use. The primary outcome (stray current) was quantified as the change in tissue temperature (°C) from baseline at the tissue closest to the tip of the endoscope. Data were reported as mean ± standard deviation. Using the 60 W coag mode while changing the orientation of the endoscope tip, tissue temperature increased by 12.1 ± 3.5 °C nearest the camera lens (p energy transfer (p = 0.04 and p = 0.002, respectively) as did utilizing the low-voltage cut mode (6.6 ± 0.5 °C, p energy transfer compared to a standard generator (1.5 ± 3.5 °C vs. 9.5 ± 0.8 °C, p energy is transferred within the endoscope during the activation of common energy devices. This could result in post-polypectomy syndrome, bleeding, or perforation outside of the endoscopist's view. Decreasing the power, utilizing low-voltage modes and/or an impedance-monitoring generator can decrease the risk of complication.

  19. Bi-directional Multi Dimension CAP Transmission for Smart Grid Communication Services

    DEFF Research Database (Denmark)

    Zhang, Xu; Binti Othman, Maisara; Pang, Xiaodan

    2012-01-01

    We experimentally demonstrate bi-directional multi dimension carrierless amplitude and phase (CAP) transmission for smart grid communication services based on optical fiber networks. The proposed system is able to support multi-Gb/s transmission with high spectral efficiency.......We experimentally demonstrate bi-directional multi dimension carrierless amplitude and phase (CAP) transmission for smart grid communication services based on optical fiber networks. The proposed system is able to support multi-Gb/s transmission with high spectral efficiency....

  20. Lidocaine lozenges for pharyngeal anesthesia during upper gastrointestinal endoscopy: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Avinash Supe

    2014-01-01

    Full Text Available Background and Objectives: A novel lozenge formulation with advantages of ease of drug administration, palatable taste and improved patient compliance could be the preferred mode of topical pharyngeal anesthesia during upper gastrointestinal endoscopy (UGE. This randomized, open-label, active-controlled study was conducted to evaluate the efficacy and safety of lidocaine lozenges versus lidocaine spray in the diagnostic gastroduodenal endoscopy in Indian patients. Subjects and Methods: Two hundred and forty-seven patients of either sex (18-80 years undergoing diagnostic gastroduodenal endoscopy were randomized either to; lidocaine lozenge 200 mg or lidocaine spray 200 mg to be applied as a single dose before gastroduodenal endoscopy. Ease of procedure, level of gag reflex, ease of application of the local anesthetic, and investigators global assessment were the primary efficacy endpoints. Need for rescue medication and patient′s global assessment were secondary efficacy endpoints. The incidence of any adverse event was the safety endpoint. Between groups, comparison was done by using appropriate statistical test. Results: Investigator reported significantly lesser procedural difficulty (P = 0.0007 and suppressed gag reflex (P < 0.0001 during UGE with lidocaine lozenge compared to spray. Ease of application of local anesthetic was reported easy in significantly more patients as compared with lidocaine spray (P = 0.001. Global assessment by patient and physician was favorable toward lozenge. Incidences of adverse events were similar in both the groups. Conclusions: The study suggests that lidocaine lozenges are an easier way of applying local oropharyngeal anesthesia, produces better suppression of gag reflex and makes the procedure easier when compared with lidocaine spray.

  1. Testicular biopsy in psittacine birds (Psittaciformes): impact of endoscopy and biopsy on health, testicular morphology, and sperm parameters.

    Science.gov (United States)

    Hänse, Maria; Krautwald-Junghanns, Maria-Elisabeth; Reitemeier, Susanne; Einspanier, Almuth; Schmidt, Volker

    2013-12-01

    Histologic examination of a testicular biopsy sample may be required to evaluate the reproductive status of male psittacine birds. The purpose of this study was to evaluate the viability of testicular sampling from live birds by assessing the impact on the birds' health, testicular integrity, and sperm quality. Testicular biopsy samples were obtained by endoscopy 4 times during 12 months from 9 cockatiels (Nymphicus hollandicus) and 7 rose-ringed parakeets (Psittacula krameri). Only 2 of 16 birds showed testicular cicatrization or divided testicular tissue after a single endoscopy. Further complications, such as damage to the air sacs or bleeding, predominantly occurred in subsequent endoscopies. In both species, endoscopy and testicular biopsy caused only minor or transient effects on sperm production and sperm quality. These results support that a single testicular biopsy is a viable method for evaluating the reproductive status of male psittacine birds.

  2. Bi-directional magnetic resonance based wireless power transfer for electronic devices

    International Nuclear Information System (INIS)

    Kar, Durga P.; Nayak, Praveen P.; Bhuyan, Satyanarayan; Mishra, Debasish

    2015-01-01

    In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84% in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency

  3. Bi-directional magnetic resonance based wireless power transfer for electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Kar, Durga P.; Nayak, Praveen P.; Bhuyan, Satyanarayan; Mishra, Debasish [Department of Electronics and Instrumentation Engineering, Institute of Technical Education and Research, Siksha ‘O’ Anushandhan University, Bhubaneswar 751030 (India)

    2015-09-28

    In order to power or charge electronic devices wirelessly, a bi-directional wireless power transfer method has been proposed and experimentally investigated. In the proposed design, two receiving coils are used on both sides of a transmitting coil along its central axis to receive the power wirelessly from the generated magnetic fields through strongly coupled magnetic resonance. It has been observed experimentally that the maximum power transfer occurs at the operating resonant frequency for optimum electric load connected across the receiving coils on both side. The optimum wireless power transfer efficiency is 88% for the bi-directional power transfer technique compared 84% in the one side receiver system. By adopting the developed bi-directional power transfer method, two electronic devices can be powered up or charged simultaneously instead of a single device through usual one side receiver system without affecting the optimum power transfer efficiency.

  4. Silent and Efficient Supersonic Bi-Directional Flying Wing

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose a Phase I study for a novel concept of a supersonic bi-directional (SBiDir) flying wing (FW) that has the potential to revolutionize supersonic flight...

  5. Bidirectional communication using delay coupled chaotic directly ...

    Indian Academy of Sciences (India)

    A symmetric bidirectional coupling is identified as a suitable method for isochronal synchronization of such lasers. The optimum values of coupling and feedback strength that can provide maximum quality of synchronization are identified. This method is successfully employed for encoding/decoding both analog and digital ...

  6. Block-classified bidirectional motion compensation scheme for wavelet-decomposed digital video

    Energy Technology Data Exchange (ETDEWEB)

    Zafar, S. [Argonne National Lab., IL (United States). Mathematics and Computer Science Div.; Zhang, Y.Q. [David Sarnoff Research Center, Princeton, NJ (United States); Jabbari, B. [George Mason Univ., Fairfax, VA (United States)

    1997-08-01

    In this paper the authors introduce a block-classified bidirectional motion compensation scheme for the previously developed wavelet-based video codec, where multiresolution motion estimation is performed in the wavelet domain. The frame classification structure described in this paper is similar to that used in the MPEG standard. Specifically, the I-frames are intraframe coded, the P-frames are interpolated from a previous I- or a P-frame, and the B-frames are bidirectional interpolated frames. They apply this frame classification structure to the wavelet domain with variable block sizes and multiresolution representation. They use a symmetric bidirectional scheme for the B-frames and classify the motion blocks as intraframe, compensated either from the preceding or the following frame, or bidirectional (i.e., compensated based on which type yields the minimum energy). They also introduce the concept of F-frames, which are analogous to P-frames but are predicted from the following frame only. This improves the overall quality of the reconstruction in a group of pictures (GOP) but at the expense of extra buffering. They also study the effect of quantization of the I-frames on the reconstruction of a GOP, and they provide intuitive explanation for the results. In addition, the authors study a variety of wavelet filter-banks to be used in a multiresolution motion-compensated hierarchical video codec.

  7. Bidirectional relations between work-related stress, sleep quality and perseverative cognition.

    Science.gov (United States)

    Van Laethem, Michelle; Beckers, Debby G J; Kompier, Michiel A J; Kecklund, Göran; van den Bossche, Seth N J; Geurts, Sabine A E

    2015-11-01

    In this longitudinal two-wave study, bidirectional relations between work-related stress and sleep quality were examined. Moreover, it was investigated whether perseverative cognition is a potential underlying mechanism in this association, related to both work-related stress and sleep quality. A randomly selected sample of Dutch employees received an online survey in 2012 and 2013. Of all invited employees, 877 participated in both waves. Structural equation modeling was performed to analyze the data. We found evidence for reversed relations between work-related stress and sleep quality. Specifically, when controlling for perseverative cognition, work-related stress was not directly related to subsequent sleep quality, but low sleep quality was associated with an increase in work-related stress over time. Moreover, negative bidirectional associations over time were found between perseverative cognition and sleep quality, and positive bidirectional associations were found between work-related stress and perseverative cognition. Lastly, a mediation analysis showed that perseverative cognition fully mediated the relationship between work-related stress and sleep quality. The study findings suggest that perseverative cognition could be an important underlying mechanism in the association between work-related stress and sleep quality. The bidirectionality of the studied relationships could be an indication of a vicious cycle, in which work-related stress, perseverative cognition, and sleep quality mutually influence each other over time. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Personalized recommendation based on heat bidirectional transfer

    Science.gov (United States)

    Ma, Wenping; Feng, Xiang; Wang, Shanfeng; Gong, Maoguo

    2016-02-01

    Personalized recommendation has become an increasing popular research topic, which aims to find future likes and interests based on users' past preferences. Traditional recommendation algorithms pay more attention to forecast accuracy by calculating first-order relevance, while ignore the importance of diversity and novelty that provide comfortable experiences for customers. There are some levels of contradictions between these three metrics, so an algorithm based on bidirectional transfer is proposed in this paper to solve this dilemma. In this paper, we agree that an object that is associated with history records or has been purchased by similar users should be introduced to the specified user and recommendation approach based on heat bidirectional transfer is proposed. Compared with the state-of-the-art approaches based on bipartite network, experiments on two benchmark data sets, Movielens and Netflix, demonstrate that our algorithm has better performance on accuracy, diversity and novelty. Moreover, this method does better in exploiting long-tail commodities and cold-start problem.

  9. Familiarity Detection is an Intrinsic Property of Cortical Microcircuits with Bidirectional Synaptic Plasticity.

    Science.gov (United States)

    Zhang, Xiaoyu; Ju, Han; Penney, Trevor B; VanDongen, Antonius M J

    2017-01-01

    Humans instantly recognize a previously seen face as "familiar." To deepen our understanding of familiarity-novelty detection, we simulated biologically plausible neural network models of generic cortical microcircuits consisting of spiking neurons with random recurrent synaptic connections. NMDA receptor (NMDAR)-dependent synaptic plasticity was implemented to allow for unsupervised learning and bidirectional modifications. Network spiking activity evoked by sensory inputs consisting of face images altered synaptic efficacy, which resulted in the network responding more strongly to a previously seen face than a novel face. Network size determined how many faces could be accurately recognized as familiar. When the simulated model became sufficiently complex in structure, multiple familiarity traces could be retained in the same network by forming partially-overlapping subnetworks that differ slightly from each other, thereby resulting in a high storage capacity. Fisher's discriminant analysis was applied to identify critical neurons whose spiking activity predicted familiar input patterns. Intriguingly, as sensory exposure was prolonged, the selected critical neurons tended to appear at deeper layers of the network model, suggesting recruitment of additional circuits in the network for incremental information storage. We conclude that generic cortical microcircuits with bidirectional synaptic plasticity have an intrinsic ability to detect familiar inputs. This ability does not require a specialized wiring diagram or supervision and can therefore be expected to emerge naturally in developing cortical circuits.

  10. Pilot randomized crossover study comparing the efficacy of transnasal disposable endosheath with standard endoscopy to detect Barrett's esophagus.

    Science.gov (United States)

    Shariff, Mohammed K; Varghese, Sibu; O'Donovan, Maria; Abdullahi, Zarah; Liu, Xinxue; Fitzgerald, Rebecca C; di Pietro, Massimiliano

    2016-02-01

    The transnasal endosheath endoscope is a new disposable technology with potential applicability to the primary care setting. The aim of this study was to evaluate the efficacy of transnasal endosheath endoscopy (TEE) for the detection of Barrett's esophagus, by comparing the diagnostic accuracy of TEE with that of standard endoscopy. This was a prospective, randomized, crossover study performed in a single tertiary referral center. Consecutive patients undergoing surveillance for Barrett's esophagus or referred for diagnostic assessment were recruited. All patients were randomized to undergo TEE followed by standard endoscopy or the reverse. Endoscopy experiences and patient preferences were evaluated using a questionnaire. Endoscopic and histologic diagnosis of Barrett's esophagus, and optical image quality of both endoscopic procedures, were compared. A total of 21 of 25 patients completed the study. TEE had sensitivity and specificity of 100 % for an endoscopic diagnosis of Barrett's esophagus, and of 66.7 % and 100 %, respectively, for the histologic diagnosis of Barrett's esophagus. The mean optical quality of standard endoscopy was significantly better than that of TEE (7.11 ± 0.42 vs. 4.06 ± 0.27; P evaluation in primary care as an initial diagnostic tool. © Georg Thieme Verlag KG Stuttgart · New York.

  11. The role of Amicar in same-day anterior and posterior spinal fusion for idiopathic scoliosis.

    Science.gov (United States)

    Thompson, George H; Florentino-Pineda, Ivan; Poe-Kochert, Connie; Armstrong, Douglas G; Son-Hing, Jochen P

    2008-09-15

    A retrospective study of the effectiveness of Amicar (epsilon aminocaproic acid). Evaluate the effectiveness of Amicar in decreasing perioperative blood loss and transfusion requirements in same-day anterior (ASF) and posterior spinal fusion (PSF) with segmental spinal instrumentation (SSI) for idiopathic scoliosis. Preliminary prospective, prospective randomized double-blind, and fibrinogen studies have demonstrated Amicar to be effective in decreasing perioperative blood loss in patients with idiopathic scoliosis undergoing PSF with SSI. Increased fibrinogen secretion is a possible explanation. There were 73 consecutive patients divided into 3 study groups based on the administration of Amicar: Group 1 (n = 16), no Amicar; Group 2 (n = 18), Amicar for the PSF with SSI only; and Group 3 (n = 39), Amicar for both ASF and PSF with SSI. All patients were managed using the same general anesthesia technique, intraoperative procedure, postoperative care path, and indications for transfusion (hemoglobin <7 g/dL). Total perioperative blood loss (estimated intraoperative blood loss for both procedures and measured postoperative chest tube and PSF wound suction drainage) and total transfusion requirements between groups were compared using one-way ANOVA. There were statistically significant decreases in mean estimated intraoperative PSF with SSI, total perioperative blood loss, and transfusion requirements in the 2 Amicar groups. However, Amicar had no significant effect on estimated intraoperative ASF blood loss, chest tube drainage, or PSF wound suction drainage. Total perioperative blood loss and transfusion requirements (cell saver, autologous, directed, and allogeneic blood) were: 3442.8 +/- 1344.0 mL and 1537.1 +/- 905.1 mL in Group 1; 2089.8 +/- 684.0 mL and 485.2 +/- 349.8 mL in Group 2; and 2184.1 +/- 1163.7 mL and 531.5 +/- 510.5 mL in Group 3. There were no Amicar related complications. Amicar was highly effective in decreasing total perioperative blood loss and

  12. Alternative Agents to Prevent Fogging in Head and Neck Endoscopy

    Directory of Open Access Journals (Sweden)

    Patorn Piromchai

    2011-01-01

    Full Text Available Background The essential factor for diagnosis and treatment of diseases in head and neck endoscopy is the visibility of the image. An anti-fogging agent can reduce this problem by minimizing surface tension to prevent the condensation of water in the form of small droplets on a surface. There is no report on the use of hibiscrub ® or baby shampoo to reduce fogging in the literature. The objective of this study was to compare the efficacy between commercial anti-fogging agent, hibiscrub ® and baby shampoo to reduce fogging for the use in head and neck endoscopy. Methods The study was conducted at the Department of Otorhinolaryngology, Faculty of Medicine, Khon Kaen University in August 2010. Commercial anti-fogging agent, baby shampoo and hibiscrub ® were applied on rigid endoscope lens before putting them into a mist generator. The images were taken at baseline, 15 seconds, 30 seconds and 1 minute. The images' identifiers were removed before they were sent to two evaluators. A visual analogue scale (VAS was used to rate the image quality from 0 to 10. Results The difference in mean VAS score between anti-fogging agent, baby shampoo and hibiscrub ® versus no agent were 5.46, 4.45 and 2.1 respectively. The commercial anti-fogging agent and baby shampoo had most protective benefit and performed significantly better than no agent ( P < 0.05. Conclusions Baby shampoo is an effective agent to prevent fogging during head and neck endoscopy and compares favourably with commercial anti-fogging agent.

  13. Blood detection in wireless capsule endoscopy using expectation maximization clustering

    Science.gov (United States)

    Hwang, Sae; Oh, JungHwan; Cox, Jay; Tang, Shou Jiang; Tibbals, Harry F.

    2006-03-01

    Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. Other endoscopies such as colonoscopy, upper gastrointestinal endoscopy, push enteroscopy, and intraoperative enteroscopy could be used to visualize up to the stomach, duodenum, colon, and terminal ileum, but there existed no method to view most of the small intestine without surgery. With the miniaturization of wireless and camera technologies came the ability to view the entire gestational track with little effort. A tiny disposable video capsule is swallowed, transmitting two images per second to a small data receiver worn by the patient on a belt. During an approximately 8-hour course, over 55,000 images are recorded to a worn device and then downloaded to a computer for later examination. Typically, a medical clinician spends more than two hours to analyze a WCE video. Research has been attempted to automatically find abnormal regions (especially bleeding) to reduce the time needed to analyze the videos. The manufacturers also provide the software tool to detect the bleeding called Suspected Blood Indicator (SBI), but its accuracy is not high enough to replace human examination. It was reported that the sensitivity and the specificity of SBI were about 72% and 85%, respectively. To address this problem, we propose a technique to detect the bleeding regions automatically utilizing the Expectation Maximization (EM) clustering algorithm. Our experimental results indicate that the proposed bleeding detection method achieves 92% and 98% of sensitivity and specificity, respectively.

  14. Prevalence of gastroduodenal ulcers/erosions in patients taking low-dose aspirin with either 15 mg/day of lansoprazole or 40 mg/day of famotidine: The OITA-GF study 2

    Science.gov (United States)

    2013-01-01

    Background The preventive effects of histamine 2 receptor antagonists vs. proton pump inhibitors on low-dose aspirin (LDA)-related gastroduodenal mucosal injury have not been fully investigated. We conducted a cross-sectional study to compare the prevalence of gastroduodenal ulcers or erosions in patients taking LDA with either 40 mg/day of famotidine or 15 mg/day of lansoprazole for at least three months. Methods Of 84 eligible patients, two taking 40 mg/day of famotidine and four taking 15 mg/day of lansoprazole refused to undergo upper gastrointestinal endoscopy. Ultimately, we performed upper gastrointestinal endoscopy in 78 patients taking either 40 mg/day of famotidine (group F, n = 31) or 15 mg/day of lansoprazole (group L, n = 47). The prevalence of gastroduodenal ulcers or erosions and the magnitude of gastric mucosal injury evaluated using modified Lanza scores were compared between the two groups. Results No patients in either group had gastroduodenal ulcers. Gastroduodenal erosions were more prevalent in group F than in group L (48.4% vs. 17.0%, p = 0.005). The modified Lanza scores (mean ± SD) were significantly higher in group F than in group L (0.9 ± 1.3 vs. 0.3 ± 0.7, p = 0.007). A multivariate logistic regression analysis showed that the use of lansoprazole was negatively associated with gastroduodenal erosions. Conclusions This study suggests that 15 mg/day of lansoprazole may be more effective in preventing the development of LDA-related gastroduodenal erosions than 40 mg/day of famotidine. The preventive effects of these two regimens on the development of LDA-related gastroduodenal ulcers require further investigation. PMID:23531145

  15. An ingested foreign body: two sides of the same coin?

    Science.gov (United States)

    Varadharajan, Kiran; Magill, Jennifer; Patel, Kalpesh

    2014-04-09

    A 2-year-old child presented to the emergency department with an acute onset of dysphagia and stertor. A plain anteroposterior chest X-ray revealed a single circular opacity in the middle third of the oesophagus consistent with an ingested coin. The child was taken to the theatre for rigid pharyngo-oesophagoscopy and removal of the coin. After the first coin was removed subsequent endoscopic examination revealed a second coin at the same location. This extremely rare case of two ingested coins becoming impacted with perfect radiological alignment emphasises the importance of thorough examination on endoscopy and the potential limitations of an X-ray in initial assessment of an ingested foreign body.

  16. Usefulness of virtual endoscopy for evaluating the relationship between the neck of intracranial aneurysm and surrounding vessels

    International Nuclear Information System (INIS)

    Ikeda, Jota; Horie, Hitoshi; Ishikura, Reiichi; Ando, Kumiko; Morikawa, Tsutomu; Tominaga, Satoru; Nakao, Norio

    2000-01-01

    Application of three-dimensional CT virtual endoscopy for evaluation of the neck and surrounding vessels of intracranial aneurysms. 3D-CT virtual endoscopy (VE) is a reconstructed image using computer processing of 3D-CT images. We evaluated the usefulness of a virtual endoscopy to analyze the relationship between the neck of an intracranial aneurysm and the surrounding vessels. Eight cases with intracranial aneurysms underwent digital subtraction angiography (DSA) and enhanced CT with transarterial infusion of contrast media. 3D-CT angiogram (3D-CTA) and virtual endoscopic images were obtained from the CT image data sets using surface rendering method. The relationship between the neck of an intracranial aneurysm and the surrounding vessels was confirmed by operation or IVR. VE clearly visualized the neck and surrounding vessels in all cases. Operation/IVR findings agreed with the virtual endoscopic findings in all cases, but not with the DSA or 3D-CTA findings in 4 and 2 cases, respectively. 3D-CTA and virtual endoscopy clearly visualizes the relationship between cerebral aneurysms and surrounding vessels, which is useful for determining IVR procedures. (author)

  17. Synchronization and bidirectional communication without delay line using strong mutually coupled semiconductor lasers

    Science.gov (United States)

    Li, Guang-Hui; Wang, An-Bang; Feng, Ye; Wang, Yang

    2010-07-01

    This paper numerically demonstrates synchronization and bidirectional communication without delay line by using two semiconductor lasers with strong mutual injection in a face-to-face configuration. These results show that both of the two lasers' outputs synchronize with their input chaotic carriers. In addition, simulations demonstrate that this kind of synchronization can be used to realize bidirectional communications without delay line. Further studies indicate that within a small deviation in message amplitudes of two sides (±6%), the message can be extracted with signal-noise-ratio more than 10 dB; and the signal-noise-ratio is extremely sensitive to the message rates mismatch of two sides, which may be used as a key of bidirectional communication.

  18. Synchronization and bidirectional communication without delay line using strong mutually coupled semiconductor lasers

    International Nuclear Information System (INIS)

    Guang-Hui, Li; An-Bang, Wang; Ye, Feng; Yang, Wang

    2010-01-01

    This paper numerically demonstrates synchronization and bidirectional communication without delay line by using two semiconductor lasers with strong mutual injection in a face-to-face configuration. These results show that both of the two lasers' outputs synchronize with their input chaotic carriers. In addition, simulations demonstrate that this kind of synchronization can be used to realize bidirectional communications without delay line. Further studies indicate that within a small deviation in message amplitudes of two sides (±6%), the message can be extracted with signal-noise-ratio more than 10 dB; and the signal-noise-ratio is extremely sensitive to the message rates mismatch of two sides, which may be used as a key of bidirectional communication. (general)

  19. Provision of a 'same-day' ultrasound service in an inner-city NHS trust: report on experience and lessons learned after the first 2 years

    Energy Technology Data Exchange (ETDEWEB)

    Hawtin, K.E.; Hameed, S.; Ramachandran, R.; Harvey, C.J.; Lim, A.K.; Gishen, P. [Departments of Radiology, Imperial College NHS Trust, London (United Kingdom); Roddie, M.E., E-mail: mary.roddie@imperial.nhs.u [Departments of Radiology, Imperial College NHS Trust, London (United Kingdom)

    2010-01-15

    Aim: To assess the effect of changing from an 'appointment' to a 'same-day' ultrasound (US) service on referral pattern, departmental workload, and patient satisfaction. Materials and methods: To reduce US waiting time of 3 weeks for routine examinations, a 'same-day' service was started for outpatients and general practitioner (GP) patients in September 2006. To examine the effect of this change a retrospective assessment was performed of workload during 1 week in June 2006 (appointments only) and the same week in 2008, 22 months after the implementation of the new service. Distance travelled by patients and waiting time was recorded. Patient satisfaction with the service was assessed by questionnaire in September 2008. Results: Hospital referrals remained stable, but GP referrals increased from 99 to 367 (270%) and distance travelled by patients increased from a median of 3.1 km (range 0.1-12.1 km) in 2006 to 4.8 km (range 0.2-19.8 km) in 2008 (p < 0.001). Non-local GP referrals increased from 20/99 in 2006 (20%) to 198/367 in 2008 (54%). The increased workload was managed by flexible working by radiologists and two additional sonographers. Departmental waiting time increased for all patients with same-day patients waiting a median of 35 min (interquartile range 19-60 min). Ninety-one percent (79/87) of same-day patients rated the service excellent or good, but many requested better information on the waiting time. Conclusion: There is a demand from GPs for same-day US, and it is feasible in a large hospital with flexible radiology working and increased sonographic staffing. Unless adjacent hospitals offer a similar service, continuing rise in demand could overwhelm the service.

  20. Competence and quality assessment: the future of training in GI endoscopy

    NARCIS (Netherlands)

    V.E. Ekkelenkamp (Vivian)

    2014-01-01

    markdownabstract__Abstract__ __Introduction__: Training procedural skills in gastrointestinal endoscopy once focused on threshold numbers. However, as threshold numbers poorly reflect individual competence, the focus gradually shifts towards a more individual approach. Tools to assess and

  1. Historical analysis of experience with small bowel capsule endoscopy in a spanish tertiary hospital.

    Science.gov (United States)

    Egea Valenzuela, Juan; Carrilero Zaragoza, Gabriel; Iglesias Jorquera, Elena; Tomás Pujante, Paula; Alberca de Las Parras, Fernando; Carballo Álvarez, Fernando

    2017-02-01

    Capsule endoscopy was approved by the FDA in 2001. Gastrointestinal bleeding and inflammatory bowel disease are the main indications. It has been available in our hospital since 2004. We retrospectively analysed data from patients who underwent small bowel capsule endoscopy in our hospital from October 2004 to April 2015. Indications were divided into: Obscure gastrointestinal bleeding (occult and overt), inflammatory bowel disease, and other indications. Findings were divided into: Vascular lesions, inflammatory lesions, other lesions, normal studies, and inconclusive studies. A total of 1027 out of 1291 small bowel studies were included. Mean patient age was 56.45 years; 471 were men and 556 women. The most common lesion observed was angiectasia, as an isolated finding or associated with other lesions. Findings were significant in up to 80% of studies when the indication was gastrointestinal bleeding, but in only 50% of studies in inflammatory bowel disease. Diagnostic yield was low in the group «other indications». No major complications were reported. Small bowel capsule endoscopy has high diagnostic yield in patients with gastrointestinal bleeding, but yield is lower in patients with inflammatory bowel disease. Our experience shows that capsule endoscopy is a safe and useful tool for the diagnosis of small bowel disease. The diagnostic yield of the technique in inflammatory bowel disease must be improved. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  2. Assessment of an electronic learning system for colon capsule endoscopy: a pilot study.

    Science.gov (United States)

    Watabe, Hirotsugu; Nakamura, Tetsuya; Yamada, Atsuo; Kakugawa, Yasuo; Nouda, Sadaharu; Terano, Akira

    2016-06-01

    Training for colon capsule endoscopy (CCE) procedures is currently performed as a lecture and hands-on seminar. The aims of this pilot study were to assess the utility of an electronic learning system for CCE (ELCCE) designed for the Japanese Association for Capsule Endoscopy using an objective scoring engine, and to evaluate the efficacy of ELCCE on the acquisition of CCE reading competence. ELCCE is an Internet-based learning system with the following steps: step 1, introduction; step 2, CCE reading competence assessment test (CCAT), which evaluates the competence of CCE reading prior to training; step 3, learning reading theory; step 4, training with guidance; step 5, training without guidance; step 6, final assessment; and step 7, the same as step 2. The CCAT, step 5 and step 6 were scored automatically according to: lesion detection, diagnosis (location, size, shape of lesion), management recommendations, and quality of view. Ten trainee endoscopists were initially recruited (cohort 1), followed by a validating cohort of 11 trainee endoscopists (cohort 2). All but one participant finished ELCCE training within 7 weeks. In step 6, accuracy ranged from 53 to 98 % and was not impacted by step 2 pretest scores. The average CCAT scores significantly increased between step 2 pretest and step 7 in both cohorts, from 42 ± 18 % to 79 ± 15 % in cohort 1 (p = 0.0004), and from 52 ± 15 % to 79 ± 14 % in cohort 2 (p = 0.0003). ELCCE is useful and effective for improving CCE reading competence.

  3. Application of MR virtual endoscopy in children with hydrocephalus.

    Science.gov (United States)

    Zhao, Cailei; Yang, Jian; Gan, Yungen; Liu, Jiangang; Tan, Zhen; Liang, Guohua; Meng, Xianlei; Sun, Longwei; Cao, Weiguo

    2015-12-01

    To evaluate the performance of MR virtual endoscopy (MRVE) in children with hydrocephalus. Clinical and imaging data were collected from 15 pediatric patients with hydrocephalus and 15 normal control children. All hydrocephalus patients were confirmed by ventriculoscopy or CT imaging. The cranial 3D-T1 weighted imaging data from fast spoiled gradient echo scan (FSPGR) were transported to working station. VE images of cerebral ventricular cavity were constructed with Navigator software. Cerebral ventricular MRVE can achieve similar results as ventriculoscopy in demonstrating the morphology of ventricular wall or intracavity lesion. In addition, MRVE can observe the lesion from distal end of obstruction, as well as other areas that are inaccessible to ventriculoscopy. MRVE can also reveal the pathological change of ventricular inner wall surface, and help determine patency of the cerebral aqueduct and fourth ventricle outlet. MR virtual endoscopy provides a non-invasive diagnostic modality that can be used as a supplemental approach to ventriculoscopy. However, its sensitivity and specificity need to be determined in the large study. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. A Bidirectional Multi-Port DC-DC Converter Integrating Voltage Equalizer

    DEFF Research Database (Denmark)

    Chen, Jianfei; Hou, Shiying; Deng, Fujin

    2015-01-01

    A novel bidirectional multi-port dc-dc converter integrating voltage equalizer based on switched-capacitor voltage accumulator (SCVA) is proposed. It has two operating modes of charging and discharging for battery modules. All battery modules are connected in series indirectly and can be equalize...... battery modules with different voltages. Simulation results has shown the feasibility of the proposed converter.......A novel bidirectional multi-port dc-dc converter integrating voltage equalizer based on switched-capacitor voltage accumulator (SCVA) is proposed. It has two operating modes of charging and discharging for battery modules. All battery modules are connected in series indirectly and can be equalized...

  5. A New Bi-Directional Projection Model Based on Pythagorean Uncertain Linguistic Variable

    OpenAIRE

    Huidong Wang; Shifan He; Xiaohong Pan

    2018-01-01

    To solve the multi-attribute decision making (MADM) problems with Pythagorean uncertain linguistic variable, an extended bi-directional projection method is proposed. First, we utilize the linguistic scale function to convert uncertain linguistic variable and provide a new projection model, subsequently. Then, to depict the bi-directional projection method, the formative vectors of alternatives and ideal alternatives are defined. Furthermore, a comparative analysis with projection model is co...

  6. Nanotechnology to rescue bacterial bidirectional extracellular electron transfer in bioelectrochemical systems

    KAUST Repository

    Kalathil, Shafeer

    2016-03-17

    An electrically active bacterium transports its metabolically generated electrons to insoluble substrates such as electrodes via a process known as extracellular electron transport (EET). Bacterial EET is a crucial process in the geochemical cycling of metals, bioremediation and bioenergy devices such as microbial fuel cells (MFCs). Recently, it has been found that electroactive bacteria can reverse their respiratory pathways by accepting electrons from a negatively poised electrode to produce high-value chemicals such as ethanol in a process termed as microbial electrosynthesis (MES). A poor electrical connection between bacteria and the electrode hinders the EET and MES processes significantly. Also, the bidirectional EET process is sluggish and needs to be improved drastically to extend its practical applications. Several attempts have been undertaken to improve the bidirectional EET by employing various advanced nanostructured materials such as carbon nanotubes and graphene. This review covers the recent progress in the bacterial bidirectional EET processes using advanced nanostructures in the light of current understandings of bacteria–nanomaterial interactions.

  7. European Society of Gastrointestinal Endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases.

    Science.gov (United States)

    Ladas, S D; Triantafyllou, K; Spada, C; Riccioni, M E; Rey, J-F; Niv, Y; Delvaux, M; de Franchis, R; Costamagna, G

    2010-03-01

    These recommendations on video capsule endoscopy, an emerging technology with an impact on the practice of endoscopy, were developed by the European Society of Gastrointestinal Endoscopy (ESGE) Guidelines Committee. The first draft of each section was prepared by one or two members of the writing team, who were selected as experts on the content of that section on the basis of their published work. They used evidence-based methodology, performing MEDLINE and PubMed literature searches to identify relevant clinical studies. Abstracts from scientific meetings were included only if there was no published full paper on a particular topic. If there was disagreement, the first author of the Guideline made the final decision. Recommendations were graded according to the strength of the supporting evidence. The draft guideline was critically reviewed by all authors and submitted to the ESGE councillors for their critical review before approval of the final document. The ESGE Guidelines Committee acknowledges that this document is based on a critical review of the data available at the time of preparation and that further studies may be needed to clarify some aspects. Moreover, this Guideline may be revised as necessary to account for changes in technology, new data, or other aspects of clinical practice. This document should be regarded as supplying recommendations only to gastroenterologists in providing care to their patients. It is not a set of rules and should not be construed as establishing a legal standard of care, or as encouraging, advocating, requiring, or discouraging any particular treatment. These recommendations must be interpreted according to the clinician's knowledge, expertise, and clinical judgment in the management of individual patients and, if necessary, a course of action that varies from recommendations must be undertaken. Georg Thieme Verlag KG Stuttgart. New York.

  8. Quantitative analysis of patients with celiac disease by video capsule endoscopy: A deep learning method.

    Science.gov (United States)

    Zhou, Teng; Han, Guoqiang; Li, Bing Nan; Lin, Zhizhe; Ciaccio, Edward J; Green, Peter H; Qin, Jing

    2017-06-01

    Celiac disease is one of the most common diseases in the world. Capsule endoscopy is an alternative way to visualize the entire small intestine without invasiveness to the patient. It is useful to characterize celiac disease, but hours are need to manually analyze the retrospective data of a single patient. Computer-aided quantitative analysis by a deep learning method helps in alleviating the workload during analysis of the retrospective videos. Capsule endoscopy clips from 6 celiac disease patients and 5 controls were preprocessed for training. The frames with a large field of opaque extraluminal fluid or air bubbles were removed automatically by using a pre-selection algorithm. Then the frames were cropped and the intensity was corrected prior to frame rotation in the proposed new method. The GoogLeNet is trained with these frames. Then, the clips of capsule endoscopy from 5 additional celiac disease patients and 5 additional control patients are used for testing. The trained GoogLeNet was able to distinguish the frames from capsule endoscopy clips of celiac disease patients vs controls. Quantitative measurement with evaluation of the confidence was developed to assess the severity level of pathology in the subjects. Relying on the evaluation confidence, the GoogLeNet achieved 100% sensitivity and specificity for the testing set. The t-test confirmed the evaluation confidence is significant to distinguish celiac disease patients from controls. Furthermore, it is found that the evaluation confidence may also relate to the severity level of small bowel mucosal lesions. A deep convolutional neural network was established for quantitative measurement of the existence and degree of pathology throughout the small intestine, which may improve computer-aided clinical techniques to assess mucosal atrophy and other etiologies in real-time with videocapsule endoscopy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Assessment of MMP-2/-9 expression by fluorescence endoscopy for evaluation of anastomotic healing in a murine model of anastomotic leakage.

    Science.gov (United States)

    Neumann, Philipp-Alexander; Twardy, Vanessa; Becker, Felix; Geyer, Christiane; Schwegmann, Katrin; Mohr, Annika; Faust, Andreas; Lenz, Philipp; Rijcken, Emile

    2018-01-01

    Disturbance of intestinal wound closure leads to insufficient anastomotic healing and is associated with considerable morbidity following colorectal resections. Matrix metalloproteinases (MMPs) play a crucial role in regulation of wound closure. Here fluorescence endoscopy was evaluated for assessment of MMP-2/-9 expression during failed intestinal anastomotic healing. Distal colonic anastomoses were performed as a model for disturbed healing in 36 Balb/c mice. Healing was evaluated endoscopically, macroscopically, and histologically after 1, 3 and 5 days. For detection of MMP-2/-9 expression fluorescence endoscopy (FE) was used following i.v.-administration of a Cy5.5-labeled MMP-2/-9 specific tracer. FE was complemented by quantification of the fluorescence signal using the MS-FX PRO Optical Imaging System. An overall leakage score was calculated and correlated with the results of FE. With increasing incidence of anastomotic leakage from POD1 (17%) to POD5 (83%) the uptake of the MMP tracer gradually increased (signal-to-noise ratio (SNR), POD1: 17.91 ± 1.251 vs. POD3: 30.56 ± 3.03 vs. POD5: 44.8 ± 4.473, Pdetection of MMPs in the anastomosis, an overall positive predictive value of 71.4% and negative predictive value of 66.6% was calculated for detection of anastomotic leakage. During disturbed anastomotic healing increased expression of MMP-2/-9 was observed in the anastomotic tissue. Fluorescence endoscopy for detection of MMP-2/-9 during the healing process might be a promising tool for early identification of anastomotic leakage.

  10. Transparent organic light-emitting diodes with different bi-directional emission colors using color-conversion capping layers

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jonghee, E-mail: jonghee.lee@etri.re.kr [OLED Research Center, Electronics and Telecommunications Research Institute (ETRI), Daejeon 305-700 (Korea, Republic of); Institut für Angewandte Photophysik, Technische Universität Dresden, George-Bähr-Straße 1, 01062 Dresden (Germany); Koh, Tae-Wook [Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 305-701 (Korea, Republic of); Cho, Hyunsu [OLED Research Center, Electronics and Telecommunications Research Institute (ETRI), Daejeon 305-700 (Korea, Republic of); Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 305-701 (Korea, Republic of); Schwab, Tobias [Institut für Angewandte Photophysik, Technische Universität Dresden, George-Bähr-Straße 1, 01062 Dresden (Germany); Lee, Jae-Hyun [Department School of Global Convergence Studies, Hanbat National University, San 16-1, Duckmyoung-dong, Daejeon 305-719 (Korea, Republic of); Hofmann, Simone [Institut für Angewandte Photophysik, Technische Universität Dresden, George-Bähr-Straße 1, 01062 Dresden (Germany); Lee, Jeong-Ik [OLED Research Center, Electronics and Telecommunications Research Institute (ETRI), Daejeon 305-700 (Korea, Republic of); Yoo, Seunghyup [Department of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 305-701 (Korea, Republic of); and others

    2015-06-15

    We report a study on transparent organic light-emitting diodes (OLEDs) with different bi-directional emission colors, enabled by color-conversion organic capping layers. Starting from a transparent blue OLED with an uncapped Ag top electrode exhibiting an average transmittance of 33.9%, a 4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran (DCM)-doped tris-(8-hydroxy-quinolinato)-aluminum (Alq3) capping layer is applied to achieve color-conversion from blue to orange-red on the top side while maintaining almost unchanged device transmittance. This color-conversion capping layer does not only change the color of the top side emission, but also enhances the overall device efficiency due to the optical interaction of the capping layer with the primary blue transparent OLED. Top white emission from the transparent bi-directional OLED exhibits a correlated color temperature around 6000–7000 K, with excellent color stability as evidenced by an extremely small variation in color coordinate of Δ(x,y)=(0.002, 0.002) in the forward luminance range of 100–1000 cd m{sup −2}. At the same time, the blue emission color of bottom side is not influenced by the color conversion capping layer, which finally results in different emission colors of the two opposite sides of our transparent OLEDs. - Highlights: • We report transparent organic light-emitting diodes (OLEDs) with different bi-directional emission colors. • Transparent blue OLED with color-conversion organic capping layers (CCL) shows orange top side emission. • Top white emission exhibits a CCT around 7000 K, with excellent color stability on a driving voltage.

  11. Transparent organic light-emitting diodes with different bi-directional emission colors using color-conversion capping layers

    International Nuclear Information System (INIS)

    Lee, Jonghee; Koh, Tae-Wook; Cho, Hyunsu; Schwab, Tobias; Lee, Jae-Hyun; Hofmann, Simone; Lee, Jeong-Ik; Yoo, Seunghyup

    2015-01-01

    We report a study on transparent organic light-emitting diodes (OLEDs) with different bi-directional emission colors, enabled by color-conversion organic capping layers. Starting from a transparent blue OLED with an uncapped Ag top electrode exhibiting an average transmittance of 33.9%, a 4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran (DCM)-doped tris-(8-hydroxy-quinolinato)-aluminum (Alq3) capping layer is applied to achieve color-conversion from blue to orange-red on the top side while maintaining almost unchanged device transmittance. This color-conversion capping layer does not only change the color of the top side emission, but also enhances the overall device efficiency due to the optical interaction of the capping layer with the primary blue transparent OLED. Top white emission from the transparent bi-directional OLED exhibits a correlated color temperature around 6000–7000 K, with excellent color stability as evidenced by an extremely small variation in color coordinate of Δ(x,y)=(0.002, 0.002) in the forward luminance range of 100–1000 cd m −2 . At the same time, the blue emission color of bottom side is not influenced by the color conversion capping layer, which finally results in different emission colors of the two opposite sides of our transparent OLEDs. - Highlights: • We report transparent organic light-emitting diodes (OLEDs) with different bi-directional emission colors. • Transparent blue OLED with color-conversion organic capping layers (CCL) shows orange top side emission. • Top white emission exhibits a CCT around 7000 K, with excellent color stability on a driving voltage

  12. Glossopharyngeal Nerve Block versus Lidocaine Spray to Improve Tolerance in Upper Gastrointestinal Endoscopy

    Directory of Open Access Journals (Sweden)

    Moisés Ortega Ramírez

    2013-01-01

    Full Text Available Aim of the Study. To compare the effect of glossopharyngeal nerve block with topical anesthesia on the tolerance of patients to upper gastrointestinal endoscopy. Methods. We performed a clinical trial in one hundred patients undergoing upper gastrointestinal endoscopy. Subjects were randomly assigned to one of the following two groups: (1 treatment with bilateral glossopharyngeal nerve block (GFNB and intravenous midazolam or (2 treatment with topical anesthetic (TASS and intravenous midazolam. We evaluated sedation, tolerance to the procedure, hemodynamic stability, and adverse symptoms. Results. We studied 46 men and 54 women, from 17 to 78 years of age. The procedure was reported without discomfort in 48 patients (88% in the GFNB group and 32 (64% in the TAAS group; 6 patients (12% in GFNB group and 18 (36% in TAAS group reported the procedure as little discomfort (χ2=3.95, P=0.04. There was no difference in frequency of nausea (4% in both groups and retching, 4% versus 8% for GFNB and TASS group, respectively (P=0.55. Conclusions. The use of glossopharyngeal nerve block provides greater comfort and tolerance to the patient undergoing upper gastrointestinal endoscopy. It also reduces the need for sedation.

  13. Wireless capsule endoscopy of the small bowel: development, testing, and first human trials

    Science.gov (United States)

    Swain, Paul; Iddan, Gavriel J.; Meron, Gavriel; Glukhovsky, Arkady

    2001-01-01

    Small bowel endoscopy with existing endoscopes is limited by problems of discomfort and the technical difficulty of advancing far into the small-bowel. Our aim has been to develop and test wireless capsule endoscopy. Wireless endoscopes, in the form of capsules (11 x 33 mm), were constructed by Given Imaging. These were powered by silver oxide batteries and each contained a CMOS imaging chip and miniature processor, white light emitting diodes (LEDs), a short focal length lens, and a miniature transmitter and antenna. Two video frames per second were transmitted, using radio-frequency (approx. 410 MHz), to an array of aerials attached to the body. The array of aerials can also be used to calculate the position of the capsule in the body. The images were stored on a portable recorder carried on a belt and subsequently downloaded for analysis. The batteries allow more than 5 hours of recording, although the capsule generally passes through the whole small bowel in under two hours. Clear video images of the human bowel were recorded from the pylorus to the caecum. Wireless endoscopy, for the first time, allows painless optical imaging of the whole of the small bowel.

  14. Use of endoscopy in diagnosis and management of patients with dysphagia in an African setting.

    Science.gov (United States)

    Mudawi, H M Y; Mahmoud, A O A; El Tahir, M A; Suliman, S H; Ibrahim, S Z

    2010-04-01

    The objectives of this study were to define the utility of esophagogastroduodenoscopy in the diagnosis and management of patients presenting with dysphagia and to determine the relative incidence of the various causes of dysphagia in Sudan. This is a prospective, cross-sectional, descriptive, hospital-based study carried out at the endoscopy unit of Soba University Hospital, Khartoum, Sudan. All patients complaining of dysphagia underwent upper gastrointestinal endoscopy with therapeutic intervention when necessary. A total of 114 patients were enrolled in the study, with a mean age of 47 years SD +/- 19 and a male to female ratio of 1 : 1.04. A benign condition was diagnosed in 56% of the cases; this included esophageal strictures in 21% of the cases and achalasia in 14%. Malignant causes were mainly due to esophageal cancer (40.4%) and cancer of the stomach cardia (3.5%). Therapeutic intervention was attempted in 83% of the cases. Risk factors predictive of a malignant etiology were age over 40 years (P dysphagia lasting between 1 month and 1 year (P endoscopy in our African setting is an accurate and useful investigation in the diagnosis and management of patients presenting with dysphagia. Patients over the age of 40 years presenting with dysphagia and weight loss are more likely to have a neoplastic disease and should be referred for urgent endoscopy.

  15. Disparities in the receipt of fecal occult blood test versus endoscopy among Filipino American immigrants.

    Science.gov (United States)

    Maxwell, Annette E; Danao, Leda L; Crespi, Catherine M; Antonio, Cynthia; Garcia, Gabriel M; Bastani, Roshan

    2008-08-01

    This report examines disparities associated with the type of colorectal screening test, fecal occult blood test versus endoscopy, within a particular racial/ethnic group, Filipino American immigrants. Between July 2005 and October 2006, Filipino Americans aged 50 to 75 years from 31 community organizations in Los Angeles completed a 15-minute survey in English (65%) or Filipino (35%). Of the 487 respondents included in this analysis, 257 (53%) had never received any type of colorectal cancer screening. Among the 230 subjects who had ever received a routine screening test, 78 had fecal occult blood test only (16% of the total sample), and 152 had endoscopy with or without fecal occult blood test (31% of the total sample). After controlling for access to care and key demographic variables in a multivariate analysis, only two characteristics distinguished between respondents who had fecal occult blood test only versus those who had endoscopy: acculturation, assessed by percent lifetime in the United States and language of interview, and income. Our data suggest a two-tier system, fecal occult blood test for less acculturated Filipino Americans with lower income versus endoscopy for Filipino immigrants with higher levels of acculturation and income. The disparity persists after adjusting for access to care. Instead of treating minority groups as monolithic, differences within groups need to be examined so that interventions can be appropriately targeted.

  16. Bidirectional User Throughput Maximization Based on Feedback Reduction in LiFi Networks

    OpenAIRE

    Soltani, Mohammad Dehghani; Wu, Xiping; Safari, Majid; Haas, Harald

    2017-01-01

    Channel adaptive signalling, which is based on feedback, can result in almost any performance metric enhancement. Unlike the radio frequency (RF) channel, the optical wireless communications (OWCs) channel is fairly static. This feature enables a potential improvement of the bidirectional user throughput by reducing the amount of feedback. Light-Fidelity (LiFi) is a subset of OWCs, and it is a bidirectional, high-speed and fully networked wireless communication technology where visible light ...

  17. Development and implementation of a comprehensive quality assurance program at a community endoscopy facility.

    Science.gov (United States)

    Hilsden, Robert Jay; Rostom, Alaa; Dubé, Catherine; Pontifex, Darlene; McGregor, S Elizabeth; Bridges, Ronald J

    2011-10-01

    Quality assurance (QA) is a process that includes the systematic evaluation of a service, institution of improvements and ongoing evaluation to ensure that effective changes were made. QA is a fundamental component of any organized colorectal cancer screening program. However, it should play an equally important role in opportunistic screening. Establishing the processes and procedures for a comprehensive QA program can be a daunting proposition for an endoscopy unit. The present article describes the steps taken to establish a QA program at the Forzani & MacPhail Colon Cancer Screening Centre (Calgary, Alberta) - a colorectal cancer screening centre and nonhospital endoscopy unit that is dedicated to providing colorectal cancer screening-related colonoscopies. Lessons drawn from the authors' experience may help others develop their own initiatives. The Global Rating Scale, a quality assessment and improvement tool developed for the gastrointestinal endoscopy services of the United Kingdom's National Health Service, was used as the framework to develop the QA program. QA activities include monitoring the patient experience through surveys, creating endoscopist report cards on colonoscopy performance, tracking and evaluating adverse events and monitoring wait times.

  18. Opinion of gastroenterologists towards quality assurance in endoscopy.

    Science.gov (United States)

    de Jonge, Vincent; Kuipers, Ernst J; van Leerdam, Monique E

    2011-03-01

    Quality assurance has become an important issue. Many societies are adopting quality assurance programs in order to monitor and improve quality of care. To assess the opinion of gastroenterologists towards quality assurance on the endoscopy department. A survey was sent to all gastroenterologists (n=319) in the Netherlands. It assessed their opinion on a quality assurance program for endoscopy units, including its design, logistics, and content. 200 gastroenterologists (63%) completed the questionnaire. 95% had a positive opinion towards quality assurance and 67% supposed an increase in quality. 28% assumed a negative impact on the time available for patient contact by introducing a quality assurance program and 35% that the capacity would decrease. A negative attitude towards disclosure of results to insurance companies (23%) and media (53%) was reported. Female gastroenterologists were less positive to share the results with other stakeholders (pquality measurements were assessment of complications (97%), standardised reporting (96%), and adequate patient information (95%). Gastroenterologists have a positive attitude towards quality assurance. However, concerns do exist about time investment and disclosure of results to others. Information provision and procedure characteristics were considered the most important aspects of quality assurance. Copyright © 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  19. Bidirectional pulser made from pulse lines for linear induction accelerators

    International Nuclear Information System (INIS)

    Hotta, E.; Mori, T.; Kobayashi, T.; Okino, A.; Haginomori, E.; Ko, K.C.

    1996-01-01

    In order to obtain high-current charged particle beams, linear induction accelerators (LIA's) of two types have been already constructed. Conventional LIA's adopt a unidirectional pulse injected from an external pulser. The other LIA's, one of which has been proposed and constructed by Pavlovskii et al., have accelerating cavities made from pulse forming lines (PFL's). In this case, no magnetic core loaded in the cavity is necessary. However, the injected pulse must be a bidirectional one. Since a part of the voltage pulse with reversed polarity is used to accelerate a beam, it is possible to make the time integral of the output voltage zero. Thus the final magnetic energy stored in the cavity can be made zero at the end of the pulse, and the pulser-accelerator system attains the energy transfer efficiency of 100%. Accelerators of this type can be divided into two kinds, one of which has cavities with internal energy storage, and the other has cavities with energy injected from external bidirectional pulsers. The accelerator of latter type has been first proposed by Smith, but it has not been realized. Several bidirectional pulsers, which consist of three individual PFL's with arbitrary impedances and a closing switch, are analyzed. Output voltages are analytically calculated by using the method proposed by Dommel for digital computations of electromagnetic transients in networks, and conditions for attaining the maximum efficiency of energy transfer from the pulser to the beam are derived. Thus, 4 bidirectional pulsers of internal energy storage type and 2 of external pulse injection type with energy transfer efficiency of 100% are obtained, including the pulsers already reported by other authors

  20. Strong electron bidirectional anisotropies in the distant tail: ISEE 3 observations of polar rain

    International Nuclear Information System (INIS)

    Baker, D.N.; Bame, S.J.; Feldman, W.C.; Gosling, J.T.; Zwickl, R.D.; Slavin, J.A.; Smith, E.J.

    1986-01-01

    A detailed observational treatment of bidirectional electrons (--50 to 50 eV)in the distant magnetotail (rapprox. >100 R/sub E/) is presented. It is found that electrons in this energy range commonly exhibit strong, field-aligned anisotropies in the tail lobes. Because of large tail motions, the ISEE 3 data provide extensive sampling of both the north and south lobes in rapid succession. These data demonstrate directly the strong asymmetries that exist between the north and south lobes at any one time. The bidirectional fluxes are found to occur predominantly in the lobe directly connected to the sunward interplanetary magnetic field in the open magnetosphere model (north lobe for away sectors and south lobe for toward sectors). Electron anisotropy and magnetic field data are presented which show the transition from unidirectional (sheath) electron populations to bidirectional (lobe) populations. Thus we demonstrate the open nature of the distant magnetopause and show that the source of the higher-energy, bidirectional lobe electrons is the tailward directed electron heat flux population in the distant magnetosheath. Taken together, the present evidence suggests that the bidirectional electrons that we observe in the distant tail are closely related to the polar rain electrons observed previously at lower altitudes. Furthermore, these data provide strong evidence that the distant tail is composed largely of open magnetic field lines in contradistinction to some recently advanced models

  1. 5W1H Information Extraction with CNN-Bidirectional LSTM

    Science.gov (United States)

    Nurdin, A.; Maulidevi, N. U.

    2018-03-01

    In this work, information about who, did what, when, where, why, and how on Indonesian news articles were extracted by combining Convolutional Neural Network and Bidirectional Long Short-Term Memory. Convolutional Neural Network can learn semantically meaningful representations of sentences. Bidirectional LSTM can analyze the relations among words in the sequence. We also use word embedding word2vec for word representation. By combining these algorithms, we obtained F-measure 0.808. Our experiments show that CNN-BLSTM outperforms other shallow methods, namely IBk, C4.5, and Naïve Bayes with the F-measure 0.655, 0.645, and 0.595, respectively.

  2. Same-day genomic and epigenomic diagnosis of brain tumors using real-time nanopore sequencing.

    Science.gov (United States)

    Euskirchen, Philipp; Bielle, Franck; Labreche, Karim; Kloosterman, Wigard P; Rosenberg, Shai; Daniau, Mailys; Schmitt, Charlotte; Masliah-Planchon, Julien; Bourdeaut, Franck; Dehais, Caroline; Marie, Yannick; Delattre, Jean-Yves; Idbaih, Ahmed

    2017-11-01

    Molecular classification of cancer has entered clinical routine to inform diagnosis, prognosis, and treatment decisions. At the same time, new tumor entities have been identified that cannot be defined histologically. For central nervous system tumors, the current World Health Organization classification explicitly demands molecular testing, e.g., for 1p/19q-codeletion or IDH mutations, to make an integrated histomolecular diagnosis. However, a plethora of sophisticated technologies is currently needed to assess different genomic and epigenomic alterations and turnaround times are in the range of weeks, which makes standardized and widespread implementation difficult and hinders timely decision making. Here, we explored the potential of a pocket-size nanopore sequencing device for multimodal and rapid molecular diagnostics of cancer. Low-pass whole genome sequencing was used to simultaneously generate copy number (CN) and methylation profiles from native tumor DNA in the same sequencing run. Single nucleotide variants in IDH1, IDH2, TP53, H3F3A, and the TERT promoter region were identified using deep amplicon sequencing. Nanopore sequencing yielded ~0.1X genome coverage within 6 h and resulting CN and epigenetic profiles correlated well with matched microarray data. Diagnostically relevant alterations, such as 1p/19q codeletion, and focal amplifications could be recapitulated. Using ad hoc random forests, we could perform supervised pan-cancer classification to distinguish gliomas, medulloblastomas, and brain metastases of different primary sites. Single nucleotide variants in IDH1, IDH2, and H3F3A were identified using deep amplicon sequencing within minutes of sequencing. Detection of TP53 and TERT promoter mutations shows that sequencing of entire genes and GC-rich regions is feasible. Nanopore sequencing allows same-day detection of structural variants, point mutations, and methylation profiling using a single device with negligible capital cost. It

  3. Bidirectional transport of organelles: unity and struggle of opposing motors.

    Science.gov (United States)

    Bryantseva, Sofiya A; Zhapparova, Olga N

    2012-01-01

    Bidirectional transport along microtubules is ensured by opposing motor proteins: cytoplasmic dynein that drives cargo to the minus-ends and various kinesins that generally move to the plus-ends of microtubules. Regulation of motor proteins that are simultaneously bound to the same organelle is required to maintain directional transport and prevent pausing of cargo pulled away by motors of opposite polarity. Debates of the recent decade have been focused on two possible mechanisms of such regulation: (i) coordination, which implies that only one type of motors is active at a given time, and (ii) tug-of-war, which assumes that both motors are active at the same time and that direction of transport depends on the outcome of motor's confrontation. The initial idea of coordination has been challenged by observations of simultaneous activity of plus- and minus-end-directed motors applied to the same cargo. Analysis of the available data indicates that coordination and tug-of-war theories rather complement than contradict each other: cargo interacts with two teams of active motors, the resulting direction and the winner team are determined by coordination complexes, but the activity of the loser team is never completely inhibited and remains at some background level. Such persisting activity might enhance the overall efficiency of transport by increasing processivity or helping to overcome the obstacles on microtubule track. © The Author(s) Journal compilation © 2012 Portland Press Limited

  4. Bidirectional electron anisotropies in the distant tail: ISEE-3 observations of polar rain

    International Nuclear Information System (INIS)

    Baker, D.N.; Bame, S.J.; Feldman, W.C.; Gosling, J.T.; Zwickl, R.D.; Slavin, J.A.; Smith, E.J.

    1985-01-01

    A detailed observational treatment of bidirectional electrons (50 approx.500 eV) in the distant magnetotail (r greater than or equal to 100 R/sub E/) is presented. It is found that electrons in this energy range commonly exhibit strong, field-aligned anisotropies in the tail lobes. Because of large tail motions, the ISEE-3 data provide extensive sampling of both the north and south lobes in rapid succession, demonstrating directly the strong asymmetries that exist between the north and south lobes at any one time. The bidirectional fluxes are found to occur predominantly in the lobe directly connected to the sunward IMF in the open magnetosphere model (north lobe for away sectors and south lobe for toward sectors). Electron anisotropy and magnetic field data are presented which show the transition from unidirectional (sheath) electron populations to bidirectional (lobe) populations. Taken together, the present evidence suggests that the bidirectional electrons that we observe in the distant tail are closely related to the polar rain electrons observed previously at lower altitudes. Furthermore, these data provide strong evidence that the distant tail is comprised largely of open magnetic field lines in contradistinction to some recently advanced models

  5. Microscopic polyangiitis complicated with ileal involvement detected by double-balloon endoscopy: a case report.

    Science.gov (United States)

    Fukushima, Masashi; Inoue, Satoko; Ono, Yuichiro; Tamaki, Yoshitaka; Yoshimura, Hajime; Imai, Yukihiro; Inokuma, Tetsuro

    2013-03-02

    Microscopic polyangiitis is characterized by pauci-immune, necrotizing small-vessel vasculitis and an anti-neutrophil cytoplasmic antibody-associated vasculitis. Although gastrointestinal involvement in microscopic polyangiitis is not rare, endoscopic observation of it is extremely rare. To the best of our knowledge, this is the first case report of small intestinal involvement in microscopic polyangiitis detected and followed up by double-balloon endoscopy. A 70-year-old Japanese woman was transferred to our hospital for close examination of suspected small intestinal lymphoma. Retrograde double-balloon endoscopy revealed various forms of ulcers with redness and edema in the ileum. Histological findings suggested ischemic changes. Because mononeuritis multiplex and a fever spike appeared later, vasculitis was suspected. The perinuclear anti-neutrophil cytoplasmic antibody titer was elevated. Nerve biopsy results suggested vasculitis. From these findings, microscopic polyangiitis was diagnosed. It was suggested that microscopic polyangiitis caused the intestinal involvement. Intravenous pulse cyclophosphamide and oral predonisolone were started. After treatment, perinuclear anti-neutrophil cytoplasmic antibodies decreased to the normal range. Retrograde double-balloon endoscopy after treatment showed ulcer scars and no ulcer. The cause of gastrointestinal involvement in microscopic polyangiitis is ischemia due to vasculitis. It is difficult to diagnose small-vessel vasculitis by endoscopic biopsy. Although histological evidence of microscopic polyangiitis is important, the treatment should not be delayed by repeating the biopsy, because such delay can result in adverse sequela.This case report shows that microscopic polyangiitis should be considered as a differential diagnosis when small intestinal changes like those in the present case are observed by endoscopy.

  6. The burden of upper gastrointestinal endoscopy in patients with Barrett's esophagus

    NARCIS (Netherlands)

    Kruijshaar, M. E.; Kerkhof, M.; Siersema, P. D.; Steyerberg, E. W.; Homs, M. Y. V.; Essink-Bot, M.-L.

    2006-01-01

    BACKGROUND AND STUDY AIMS: Patients with Barrett's esophagus are recommended to undergo regular surveillance with upper gastrointestinal endoscopy, an invasive procedure that may cause anxiety, pain, and discomfort. We assessed to what extent patients perceived this procedure as burdensome. PATIENTS

  7. An upper gastrointestinal ulcer still bleeding after endoscopy : what comes next?

    NARCIS (Netherlands)

    Craenen, E. M. E.; Hofker, Hendrik; Peters, Frans; Kater, G. M.; Glatman, K. R.; Zijlstra, J. G.

    Introduction: Recurrent bleeding from an upper gastrointestinal ulcer when endoscopy fails is a reason for radiological or surgical treatment, both of which have their advantages and disadvantages. Case: Based on a patient with recurrent gastrointestinal bleeding, we reviewed the available evidence

  8. Bidirectional soliton spectral tunneling effects in the regime of optical event horizon

    DEFF Research Database (Denmark)

    Gu, Jie; Guo, Hairun; Wang, Shaofei

    2015-01-01

    We study the cross-phase-modulation-induced soliton spectral shifting in the regime of the optical event horizon. The perturbed soliton to either red-shifting or blue-shifting is controllable, which could evoke bidirectional soliton spectral tunneling effects.......We study the cross-phase-modulation-induced soliton spectral shifting in the regime of the optical event horizon. The perturbed soliton to either red-shifting or blue-shifting is controllable, which could evoke bidirectional soliton spectral tunneling effects....

  9. Bidirectional Relationship between Cognitive Function and Pneumonia

    Science.gov (United States)

    Shah, Faraaz Ali; Pike, Francis; Alvarez, Karina; Angus, Derek; Newman, Anne B.; Lopez, Oscar; Tate, Judith; Kapur, Vishesh; Wilsdon, Anthony; Krishnan, Jerry A.; Hansel, Nadia; Au, David; Avdalovic, Mark; Fan, Vincent S.; Barr, R. Graham

    2013-01-01

    Rationale: Relationships between chronic health conditions and acute infections remain poorly understood. Preclinical studies suggest crosstalk between nervous and immune systems. Objectives: To determine bidirectional relationships between cognition and pneumonia. Methods: We conducted longitudinal analyses of a population-based cohort over 10 years. We determined whether changes in cognition increase risk of pneumonia hospitalization by trajectory analyses and joint modeling. We then determined whether pneumonia hospitalization increased risk of subsequent dementia using a Cox model with pneumonia as a time-varying covariate. Measurements and Main Results: Of the 5,888 participants, 639 (10.9%) were hospitalized with pneumonia at least once. Most participants had normal cognition before pneumonia. Three cognition trajectories were identified: no, minimal, and severe rapid decline. A greater proportion of participants hospitalized with pneumonia were on trajectories of minimal or severe decline before occurrence of pneumonia compared with those never hospitalized with pneumonia (proportion with no, minimal, and severe decline were 67.1%, 22.8%, and 10.0% vs. 76.0%, 19.3%, and 4.6% for participants with and without pneumonia, respectively; P pneumonia, even in those with normal cognition and physical function before pneumonia (β = −0.02; P pneumonia were subsequently at an increased risk of dementia (hazard ratio, 2.24 [95% confidence interval, 1.62–3.11]; P = 0.01). Associations were independent of demographics, health behaviors, other chronic conditions, and physical function. Bidirectional relationship did not vary based on severity of disease, and similar associations were noted for those with severe sepsis and other infections. Conclusions: A bidirectional relationship exists between pneumonia and cognition and may explain how a single episode of infection in well-appearing older individuals accelerates decline in chronic health conditions and loss of

  10. Personalized recommendation based on preferential bidirectional mass diffusion

    Science.gov (United States)

    Chen, Guilin; Gao, Tianrun; Zhu, Xuzhen; Tian, Hui; Yang, Zhao

    2017-03-01

    Recommendation system provides a promising way to alleviate the dilemma of information overload. In physical dynamics, mass diffusion has been used to design effective recommendation algorithms on bipartite network. However, most of the previous studies focus overwhelmingly on unidirectional mass diffusion from collected objects to uncollected objects, while overlooking the opposite direction, leading to the risk of similarity estimation deviation and performance degradation. In addition, they are biased towards recommending popular objects which will not necessarily promote the accuracy but make the recommendation lack diversity and novelty that indeed contribute to the vitality of the system. To overcome the aforementioned disadvantages, we propose a preferential bidirectional mass diffusion (PBMD) algorithm by penalizing the weight of popular objects in bidirectional diffusion. Experiments are evaluated on three benchmark datasets (Movielens, Netflix and Amazon) by 10-fold cross validation, and results indicate that PBMD remarkably outperforms the mainstream methods in accuracy, diversity and novelty.

  11. Bidirectional electric communication between the inferior occipital gyrus and the amygdala during face processing.

    Science.gov (United States)

    Sato, Wataru; Kochiyama, Takanori; Uono, Shota; Matsuda, Kazumi; Usui, Keiko; Usui, Naotaka; Inoue, Yushi; Toichi, Motomi

    2017-09-01

    Faces contain multifaceted information that is important for human communication. Neuroimaging studies have revealed face-specific activation in multiple brain regions, including the inferior occipital gyrus (IOG) and amygdala; it is often assumed that these regions constitute the neural network responsible for the processing of faces. However, it remains unknown whether and how these brain regions transmit information during face processing. This study investigated these questions by applying dynamic causal modeling of induced responses to human intracranial electroencephalography data recorded from the IOG and amygdala during the observation of faces, mosaics, and houses in upright and inverted orientations. Model comparisons assessing the experimental effects of upright faces versus upright houses and upright faces versus upright mosaics consistently indicated that the model having face-specific bidirectional modulatory effects between the IOG and amygdala was the most probable. The experimental effect between upright versus inverted faces also favored the model with bidirectional modulatory effects between the IOG and amygdala. The spectral profiles of modulatory effects revealed both same-frequency (e.g., gamma-gamma) and cross-frequency (e.g., theta-gamma) couplings. These results suggest that the IOG and amygdala communicate rapidly with each other using various types of oscillations for the efficient processing of faces. Hum Brain Mapp 38:4511-4524, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  12. Design of PI Controlled Non Isolated Bidirectional DC to DC Converter for Electric Vehicle Application

    Science.gov (United States)

    Geetha, A.; Subramani, C.; Thamizh Thentral, T. M.; Krithika, V.; Usha, S.

    2018-04-01

    Non isolated Bidirectional DC-DC Converter (NIBDDC) is a good interface between DC source and inverter Fed induction motor drive. This paper deals with comparison between open loop and PI controlled Bidirectional DC to DC Converter Inverter System (BDDCIS). The modelling and control of BDDC is becomes an important issue. Open loop BDDCIS and closed loop PI controlled BDDCIS are designed, modelled and simulated using Matlab- simulink and their results are presented. The investigations indicate superior performance of PI controlled BDDCIS. The proposed BDDCIS has advantages like bidirectional power transfer ability, reduced hardware count and improved dynamic response.

  13. Impact of operator fatigue on endoscopy performance: implications for procedure scheduling.

    LENUS (Irish Health Repository)

    Harewood, Gavin C

    2009-08-01

    With increasing volumes of endoscopic procedures, endoscopists\\' workload has had to increase to meet this escalating demand. The aim of this study was to characterize the impact of endoscopist fatigue on quality of endoscopy performance by comparing outcomes based on chronological procedure order.

  14. Parenting and children's externalizing behavior: Bidirectionality during toddlerhood

    NARCIS (Netherlands)

    Verhoeven, Marjolein; Junger, Marianne; van Aken, Chantal; Dekovic, Maja; van Aken, Marcel A.G.

    2010-01-01

    This study examined the bidirectional relationship between parenting and boys' externalizing behaviors in a four-wave longitudinal study of toddlers. Participants were 104 intact two-parent families with toddler sons. When their sons were 17, 23, 29, and 35 months of age, mothers and fathers

  15. A Current-Fed Isolated Bidirectional DC-DC Converter

    DEFF Research Database (Denmark)

    Sun, Xiaofeng; Wu, Xiaoying; Shen, Yanfeng

    2017-01-01

    This paper proposes a current-fed isolated bidirectional DC-DC converter (CF-IBDC) which has the advantages of wide input voltage range, low input current ripple, low conduction losses, and soft switching over the full operating range. Compared with conventional CF-IBDCs, the voltage spikes...

  16. "Leopard skin sign": the use of narrow-band imaging with magnification endoscopy in celiac disease.

    Science.gov (United States)

    Tchekmedyian, Asadur J; Coronel, Emmanuel; Czul, Frank

    2014-01-01

    Celiac Disease (CD) is an immune reaction to gluten containing foods such as rye, wheat and barley. This condition affects individuals with a genetic predisposition; it targets the small bowel and may cause symptoms including diarrhea, malabsorption, weight loss, abdominal pain and bloating. The diagnosis is made by serologic testing of celiac-specific antibodies and confirmed by histology. Certain endoscopic characteristics, such as scalloping, reduction in the number of folds, mosaic-pattern mucosa or nodular mucosa, are suggestive of CD and can be visualized under white light endoscopy. Due to its low sensitivity, endoscopy alone is not recommended to diagnose CD; however, enhanced visual identification of suspected mucosal abnormalities through the use of new technologies, such as narrow band imaging with magnification (NBI-ME), could assist in targeting biopsies and thereby increasing the sensitivity of endoscopy. This is a case series of seven patients with serologic and histologic diagnoses of CD who underwent upper endoscopies with NBI-ME imaging technology as part of their CD evaluation. By employing this imaging technology, we could identify patchy atrophy sites in a mosaic pattern, with flattened villi and alteration of the central capillaries of the duodenal mucosa. We refer to this epithelial pattern as "Leopard Skin Sign". Since epithelial lesions are easily seen using NBI-ME, we found it beneficial for identifying and targeting biopsy sites. Larger prospective studies are warranted to confirm our findings.

  17. Evolution of bidirectional sex change and gonochorism in fishes of the gobiid genera Trimma, Priolepis, and Trimmatom

    Science.gov (United States)

    Sunobe, Tomoki; Sado, Tetsuya; Hagiwara, Kiyoshi; Manabe, Hisaya; Suzuki, Toshiyuki; Kobayashi, Yasuhisa; Sakurai, Makoto; Dewa, Shin-ichi; Matsuoka, Midori; Shinomiya, Akihiko; Fukuda, Kazuya; Miya, Masaki

    2017-04-01

    Size-advantage and low-density models have been used to explain how mating systems favor hermaphroditism or gonochorism. However, these models do not indicate historical transitions in sexuality. Here, we investigate the evolution of bidirectional sex change and gonochorism by phylogenetic analysis using the mitochondrial gene of the gobiids Trimma (31 species), Priolepis (eight species), and Trimmatom (two species). Trimma and Priolepis formed a clade within the sister group Trimmatom. Gonadal histology and rearing experiments revealed that Trimma marinae, Trimma nasa, and Trimmatom spp. were gonochoric, whereas all other Trimma and Priolepis spp. were bidirectional sex changers or inferred ones. A maximum-likelihood reconstruction analysis demonstrated that the common ancestor of the three genera was gonochoristic. Bidirectional sex change probably evolved from gonochorism in a common ancestor of Trimma and Priolepis. As the gonads of bidirectional sex changers simultaneously contain mature ovarian and immature testicular components or vice versa, individuals are always potentially capable of functioning as females or males, respectively. Monogamy under low-density conditions may have been the ecological condition for the evolution of bidirectional sex change in a common ancestor. As T. marinae and T. nasa are a monophyletic group, gonochorism should have evolved from bidirectional sex change in a common ancestor.

  18. Flexor Digitorum Accessorius Longus: Importance of Posterior Ankle Endoscopy

    Directory of Open Access Journals (Sweden)

    Jorge Pablo Batista

    2015-01-01

    Full Text Available Endoscopy for the posterior region of the ankle through two portals is becoming more widespread for the treatment of a large number of conditions which used to be treated with open surgery years ago. The tendon of the flexor hallucis longus (FHL travels along an osteofibrous tunnel between the posterolateral and posteromedial tubercles of the talus. Chronic inflammation of this tendon may lead to painful stenosing tenosynovitis. The aim of this report is to describe two cases depicting an accessory tendon which is an anatomical variation of the flexor hallucis longus in patients with posterior friction syndrome due to posterior ankle impingement and associated with a posteromedial osteochondral lesion of the talus. The anatomical variation (FDAL described was a finding during an endoscopy of the posterior region of the ankle, and we have spared it by sectioning the superior flexor retinaculum only. The accessory flexor digitorum longus is an anatomical variation and should be taken into account when performing an arthroscopy of the posterior region of the ankle. We recommend this treatment on this type of injury although we admit this does not make a definite conclusion.

  19. Valeur de l'endoscopie de routine dans le diagnostic de la gastrite ...

    African Journals Online (AJOL)

    Valeur de l'endoscopie de routine dans le diagnostic de la gastrite chronique antrale à Yaoundé. D Noah Noah, F Ankouane Andoulo, SAF Eloumou Bagnaka, PJA Atangana, C Tzeuton, EC Ndjitoyap Ndam ...

  20. Optimization Control of Bidirectional Cascaded DC-AC Converter Systems

    DEFF Research Database (Denmark)

    Tian, Yanjun

    in bidirectional cascaded converter. This research work analyses the control strategies based on the topology of dual active bridges converter cascaded with a three phase inverter. It firstly proposed a dc link voltage and active power coordinative control method for this cascaded topology, and it can reduce dc....... The connections of the renewable energy sources to the power system are mostly through the power electronic converters. Moreover, for high controllability and flexibility, power electronic devices are gradually acting as the interface between different networks in power systems, promoting conventional power...... the bidirectional power flow in the distribution level of power systems. Therefore direct contact of converters introduces significant uncertainties to power system, especially for the stability and reliability. This dissertation studies the optimization control of the two stages directly connected converters...

  1. Bidirectional selection between two classes in complex social networks.

    Science.gov (United States)

    Zhou, Bin; He, Zhe; Jiang, Luo-Luo; Wang, Nian-Xin; Wang, Bing-Hong

    2014-12-19

    The bidirectional selection between two classes widely emerges in various social lives, such as commercial trading and mate choosing. Until now, the discussions on bidirectional selection in structured human society are quite limited. We demonstrated theoretically that the rate of successfully matching is affected greatly by individuals' neighborhoods in social networks, regardless of the type of networks. Furthermore, it is found that the high average degree of networks contributes to increasing rates of successful matches. The matching performance in different types of networks has been quantitatively investigated, revealing that the small-world networks reinforces the matching rate more than scale-free networks at given average degree. In addition, our analysis is consistent with the modeling result, which provides the theoretical understanding of underlying mechanisms of matching in complex networks.

  2. Obscure gastrointestinal bleeding: difficulties in comparing CT enterography and video capsule endoscopy

    International Nuclear Information System (INIS)

    Soyer, Philippe

    2012-01-01

    A paper reports the results of a retrospective study that was designed to evaluate the potential role of video capsule endoscopy (VCE) in elucidating the cause of bleeding in patients with obscure gastrointestinal bleeding (OGIB) for whom CT enterography was negative. The authors highlight the limitations of dual-phase CT enterography for the detection of flat lesions of the small bowel such as ulcers, angiodysplasias or arteriovenous malformations, and confirm the superiority of VCE for the detection of this category of lesions. This commentary discusses some of the issues raised. Key Points circle Video capsule endoscopy surpasses CT enterography in detecting flat small bowel lesions. circle Retrospective VCE and CT enterography findings in obscure bleeding need further evaluation. circle A fair and unbiased comparison of the two investigations is still needed. (orig.)

  3. Learning to Monitor Machine Health with Convolutional Bi-Directional LSTM Networks.

    Science.gov (United States)

    Zhao, Rui; Yan, Ruqiang; Wang, Jinjiang; Mao, Kezhi

    2017-01-30

    In modern manufacturing systems and industries, more and more research efforts have been made in developing effective machine health monitoring systems. Among various machine health monitoring approaches, data-driven methods are gaining in popularity due to the development of advanced sensing and data analytic techniques. However, considering the noise, varying length and irregular sampling behind sensory data, this kind of sequential data cannot be fed into classification and regression models directly. Therefore, previous work focuses on feature extraction/fusion methods requiring expensive human labor and high quality expert knowledge. With the development of deep learning methods in the last few years, which redefine representation learning from raw data, a deep neural network structure named Convolutional Bi-directional Long Short-Term Memory networks (CBLSTM) has been designed here to address raw sensory data. CBLSTM firstly uses CNN to extract local features that are robust and informative from the sequential input. Then, bi-directional LSTM is introduced to encode temporal information. Long Short-Term Memory networks(LSTMs) are able to capture long-term dependencies and model sequential data, and the bi-directional structure enables the capture of past and future contexts. Stacked, fully-connected layers and the linear regression layer are built on top of bi-directional LSTMs to predict the target value. Here, a real-life tool wear test is introduced, and our proposed CBLSTM is able to predict the actual tool wear based on raw sensory data. The experimental results have shown that our model is able to outperform several state-of-the-art baseline methods.

  4. Learning to Monitor Machine Health with Convolutional Bi-Directional LSTM Networks

    Directory of Open Access Journals (Sweden)

    Rui Zhao

    2017-01-01

    Full Text Available In modern manufacturing systems and industries, more and more research efforts have been made in developing effective machine health monitoring systems. Among various machine health monitoring approaches, data-driven methods are gaining in popularity due to the development of advanced sensing and data analytic techniques. However, considering the noise, varying length and irregular sampling behind sensory data, this kind of sequential data cannot be fed into classification and regression models directly. Therefore, previous work focuses on feature extraction/fusion methods requiring expensive human labor and high quality expert knowledge. With the development of deep learning methods in the last few years, which redefine representation learning from raw data, a deep neural network structure named Convolutional Bi-directional Long Short-Term Memory networks (CBLSTM has been designed here to address raw sensory data. CBLSTM firstly uses CNN to extract local features that are robust and informative from the sequential input. Then, bi-directional LSTM is introduced to encode temporal information. Long Short-Term Memory networks(LSTMs are able to capture long-term dependencies and model sequential data, and the bi-directional structure enables the capture of past and future contexts. Stacked, fully-connected layers and the linear regression layer are built on top of bi-directional LSTMs to predict the target value. Here, a real-life tool wear test is introduced, and our proposed CBLSTM is able to predict the actual tool wear based on raw sensory data. The experimental results have shown that our model is able to outperform several state-of-the-art baseline methods.

  5. Encoding Strategy for Maximum Noise Tolerance Bidirectional Associative Memory

    National Research Council Canada - National Science Library

    Shen, Dan

    2003-01-01

    In this paper, the Basic Bidirectional Associative Memory (BAM) is extended by choosing weights in the correlation matrix, for a given set of training pairs, which result in a maximum noise tolerance set for BAM...

  6. Detection of rib fractures in minor chest injuries: a comparison between ultrasonography and radiography performed on the same day

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Soo; Back, Chang Hee; Lee, Kyung Rae; Shin, Yun Hack; Whang, Yeong Seop; Jeong, Ku Young [Yeosu Baek Hospital, Yeosu (Korea, Republic of); Chung, Soo Hyun [NamWon Medical Center, NamWon (Korea, Republic of); Whang, Cheol Mog [Konyang University Hospital, Daejeon (Korea, Republic of)

    2007-04-15

    We wished to compare the ability of ultrasonography and radiography performed on the same day to detect rib fractures in minor chest injuries. Two hundred and fifteen patients with minor chest injuries were selected. Radiography and ultrasonography were performed on the same day with these patients. Chest wall pain was the only presenting symptom. Two radiologists performed ultrasonography. Fractures were identified by a disruption of the anterior margin of the rib and costal cartilage. The incidence and location of fractures and complications revealed by radiography and ultrasonography were compared. Radiographs revealed the presence of 70 rib fractures in 50 (23%) of 215 patients and ultrasonography revealed the presence of 203 rib fractures in 133 (62%) of 215 patients. Ultrasonography uniquely identified 133 rib fractures in 83 patients. Ultrasonography identified a 2.9 fold increase in the number of fractures in a 2.6 fold number of subjects as compared to radiography. Of the 203 sonographically detected fractures, 201 were located in the rib, one was located at the costochondral junction, and one in the costal cartilage. There were no complications seen by either radiography or ultrasonography. Ultrasonography reveals more fractures than those that may be overlooked on radiography for minor chest injuries.

  7. Detection of rib fractures in minor chest injuries: a comparison between ultrasonography and radiography performed on the same day

    International Nuclear Information System (INIS)

    Cho, Yong Soo; Back, Chang Hee; Lee, Kyung Rae; Shin, Yun Hack; Whang, Yeong Seop; Jeong, Ku Young; Chung, Soo Hyun; Whang, Cheol Mog

    2007-01-01

    We wished to compare the ability of ultrasonography and radiography performed on the same day to detect rib fractures in minor chest injuries. Two hundred and fifteen patients with minor chest injuries were selected. Radiography and ultrasonography were performed on the same day with these patients. Chest wall pain was the only presenting symptom. Two radiologists performed ultrasonography. Fractures were identified by a disruption of the anterior margin of the rib and costal cartilage. The incidence and location of fractures and complications revealed by radiography and ultrasonography were compared. Radiographs revealed the presence of 70 rib fractures in 50 (23%) of 215 patients and ultrasonography revealed the presence of 203 rib fractures in 133 (62%) of 215 patients. Ultrasonography uniquely identified 133 rib fractures in 83 patients. Ultrasonography identified a 2.9 fold increase in the number of fractures in a 2.6 fold number of subjects as compared to radiography. Of the 203 sonographically detected fractures, 201 were located in the rib, one was located at the costochondral junction, and one in the costal cartilage. There were no complications seen by either radiography or ultrasonography. Ultrasonography reveals more fractures than those that may be overlooked on radiography for minor chest injuries

  8. Validation of the National Aeronautics and Space Administration Task Load Index as a tool to evaluate the learning curve for endoscopy training.

    Science.gov (United States)

    Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain

    2014-03-01

    Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists⁄surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The 'Endoscopy Task Load Index' was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers.

  9. Stationary oscillation for nonautonomous bidirectional associative memory neural networks with impulse

    International Nuclear Information System (INIS)

    Zhang Yinping

    2009-01-01

    In this paper, we study the existence, uniqueness and global stability of periodic solution (i.e. stationary oscillation) for general bidirectional associative memory neural networks with impulses. Some sufficient conditions are obtained for stationary oscillation of the nonautonomous bidirectional associative memory neural networks with impulses. It is derived by using a new method which is different from those of previous literatures, and a assumption in previous results does not required. The model considered is more general and some previous results are extended and improved. An illustrative example is given to demonstrate the effectiveness and less conservativeness of the obtained results.

  10. Colours sometimes count: awareness and bidirectionality in grapheme-colour synaesthesia.

    Science.gov (United States)

    Johnson, Addie; Jepma, Marieke; de Jong, Ritske

    2007-10-01

    Three experiments were conducted with 10 grapheme-colour synaesthetes and 10 matched controls to investigate (a) whether awareness of the inducer grapheme is necessary for synaesthetic colour induction and (b) whether grapheme-colour synaesthesia may be bidirectional in the sense that not only do graphemes induce colours, but that colours influence the processing of graphemes. Using attentional blink and Stroop paradigms with digit targets, we found that some synaesthetes did report "seeing" synaesthetic colours even when they were not able to report the inducing digit. Moreover, congruency effects (effects of matching the colour of digit presentation with the synaesthetic colour associated with that digit) suggested that grapheme-colour synaesthesia can be bidirectional, at least for some synaesthetes.

  11. Bidirectional dc-to-dc Power Converter

    Science.gov (United States)

    Griesbach, C. R.

    1986-01-01

    Solid-state, series-resonant converter uses high-voltage thyristors. Converter used either to convert high-voltage, low-current dc power to lowvoltage, high current power or reverse. Taking advantage of newly-available high-voltage thyristors to provide better reliability and efficiency than traditional converters that use vacuum tubes as power switches. New converter essentially maintenance free and provides greatly increased mean time between failures. Attractive in industrial applications whether or not bidirectional capability is required.

  12. Pulse oximetry and supplemental oxygen during gastrointestinal endoscopy: a critical review

    DEFF Research Database (Denmark)

    Holm, C; Rosenberg, J

    1996-01-01

    A high proportion of the mortality and morbidity associated with endoscopic procedures may be of cardiopulmonary origin. For this reason, the appropriate degree of monitoring and prophylactic measures to be used in the sedated patient undergoing endoscopy has become a topic of discussion during r...

  13. Virtual endoscopy using spiral CT in patients with carcinomas of the hypopharynx and larynx

    International Nuclear Information System (INIS)

    Song, Sang Gook; Seo, Jeong Jin; Chung, Tae Woong; Kim, Hyeong Kil; Jeong, Gwang Woo; Jeong, Yong Yeon; Kang, Heoung Keun; Cho, Jae Sik

    2000-01-01

    To compare the usefulness of virtual endoscopy using spiral CT with that of laryngoscopy in the detection and evaluation of laryngeal and pharyngeal carcinomas. Twenty-four patients with pathologically proven laryngeal and pharyngeal carcinomas underwent laryngoscopy and virtual endoscopy using spiral CT. Eleven of the carcinomas were supraglottic, five were glottic, and eight were hypopharyngeal. Source images obtained by spiral CT were transmitted to an independent workstation and virtual endoscopic images were obtained using Navigator software. These were graded according to their quality (good, fair, bad), and were interpreted by two radiologists who were blinded to the conventional endoscopic findings. These latter were subsequently compared with the virtual endoscopic findings in terms of similarity to laryngoscopic examination and detectability of lesions. The overall image quality of virtual endoscopy was good in 16 cases (67%), fair in eight (33%), and bad in no case. Among the 11 supraglottic carcinomas, image quality was good in seven cases (64%), and fair in four (36%). In four of the five glottic carcinomas (80%) quality was good, and in one case (20%) it was fair, while among the eight hypopharyngeal carcinomas, quality was good in five cases (63%), and fair in three (37%). Overall, detection of the lesion was possible in 23 cases (96%). Due to the small size of the lesion, the one case of glottic carcinoma was not detected. Virtual endoscopy using spiral CT is a safe and noninvasive method, and also successfully detects laryngeal and pharyngeal lesions, with good image quality. For the evaluation of laryngeal and hypopharyngeal carcinoma, its use ma complement that of axial CT. (author)

  14. Upper gastrointestinal endoscopy in patients aged 85 years or more. Results of a feasibility study in a district general hospital.

    NARCIS (Netherlands)

    Kouwen, M.C.A. van; Drenth, J.P.H.; Verhoeven, H.M.; Bos, L.P.; Engels, L.G.

    2003-01-01

    We performed a cross sectional analysis of the feasibility and yield of upper gastrointestinal endoscopy (UGE) in a cohort of patients aged 85 years or more. The study involved 218 patients who underwent diagnostic upper gastrointestinal endoscopy in a district general hospital between 1994 and

  15. Development and Implementation of a Comprehensive Quality Assurance Program at a Community Endoscopy Facility

    Directory of Open Access Journals (Sweden)

    Robert J Hilsden

    2011-01-01

    Full Text Available Quality assurance (QA is a process that includes the systematic evaluation of a service, institution of improvements and ongoing evaluation to ensure that effective changes were made. QA is a fundamental component of any organized colorectal cancer screening program. However, it should play an equally important role in opportunistic screening. Establishing the processes and procedures for a comprehensive QA program can be a daunting proposition for an endoscopy unit. The present article describes the steps taken to establish a QA program at the Forzani & MacPhail Colon Cancer Screening Centre (Calgary, Alberta – a colorectal cancer screening centre and nonhospital endoscopy unit that is dedicated to providing colorectal cancer screening-related colonoscopies. Lessons drawn from the authors’ experience may help others develop their own initiatives. The Global Rating Scale, a quality assessment and improvement tool developed for the gastrointestinal endoscopy services of the United Kingdom’s National Health Service, was used as the framework to develop the QA program. QA activities include monitoring the patient experience through surveys, creating endoscopist report cards on colonoscopy performance, tracking and evaluating adverse events and monitoring wait times.

  16. Non-steroidal anti-inflammatory drug-induced small bowel injuries identified by double-balloon endoscopy

    Science.gov (United States)

    Hayashi, Yoshikazu; Yamamoto, Hironori; Kita, Hiroto; Sunada, Keijiro; Sato, Hiroyuki; Yano, Tomonori; Iwamoto, Michiko; Sekine, Yutaka; Miyata, Tomohiko; Kuno, Akiko; Iwaki, Takaaki; Kawamura, Yoshiyuki; Ajibe, Hironari; Ido, Kenichi; Sugano, Kentaro

    2005-01-01

    AIM: To clarify clinical features of the NSAID-induced small bowel lesions using a new method of endoscopy. METHODS: This is a retrospective study and we analyzed seven patients with small bowel lesions while taking NSAIDs among 61 patients who had undergone double-balloon endoscopy because of gastro-intestinal bleeding or anemia between September 2000 and March 2004, at Jichi Medical School Hospital in Japan. Neither conventional EGD nor colonoscopy revealed any lesions of potential bleeding sources including ulcerations. Double-balloon endoscopy was carried out from oral approach in three patients, from anal approach in three patients, and from both approaches in one patient. RESULTS: Ulcers or erosions were observed in the ileum in six patients and in the jejunum in one patient, respectively. The ulcers were multiple in all the patients with different features from tiny punched out ulcers to deep ulcerations with oozing hemorrhage or scar. All the patients recovered uneventfully and had full resolution of symptoms after suspension of the drug. CONCLUSION: NSAIDs can induce injuries in the small bowel even in patients without any lesions in both the stomach and colon. PMID:16097059

  17. Biophysical information in asymmetric and symmetric diurnal bidirectional canopy reflectance

    Science.gov (United States)

    Vanderbilt, Vern C.; Caldwell, William F.; Pettigrew, Rita E.; Ustin, Susan L.; Martens, Scott N.; Rousseau, Robert A.; Berger, Kevin M.; Ganapol, B. D.; Kasischke, Eric S.; Clark, Jenny A.

    1991-01-01

    The authors present a theory for partitioning the information content in diurnal bidirectional reflectance measurements in order to detect differences potentially related to biophysical variables. The theory, which divides the canopy reflectance into asymmetric and symmetric functions of solar azimuth angle, attributes asymmetric variation to diurnal changes in the canopy biphysical properties. The symmetric function is attributed to the effects of sunlight interacting with a hypothetical average canopy which would display the average diurnal properties of the actual canopy. The authors analyzed radiometer data collected diurnally in the Thematic Mapper wavelength bands from two walnut canopies that received differing irrigation treatments. The reflectance of the canopies varied with sun and view angles and across seven bands in the visible, near-infrared, and middle infrared wavelength regions. Although one of the canopies was permanently water stressed and the other was stressed in mid-afternoon each day, no water stress signature was unambiguously evident in the reflectance data.

  18. A prospective randomized study comparing transnasal and peroral 5-mm ultrathin endoscopy

    Directory of Open Access Journals (Sweden)

    Lian-Feng Lin

    2014-06-01

    Conclusion: PO intubation seems an excellent alternative method when using a 5-mm ultrathin endoscopy because it achieves comparable patient tolerance, acceptance, and satisfaction as TN intubation, takes less time and causes lower intubation failure and epistaxis.

  19. Linearly and nonlinearly bidirectionally coupled synchronization of hyperchaotic systems

    International Nuclear Information System (INIS)

    Zhou Jin; Lu Junan; Wu Xiaoqun

    2007-01-01

    To date, there have been many results about unidirectionally coupled synchronization of chaotic systems. However, much less work is reported on bidirectionally-coupled synchronization. In this paper, we investigate the synchronization of two bidirectionally coupled Chen hyperchaotic systems, which are coupled linearly and nonlinearly respectively. Firstly, linearly coupled synchronization of two hyperchaotic Chen systems is investigated, and a theorem on how to choose the coupling coefficients are developed to guarantee the global asymptotical synchronization of two coupled hyperchaotic systems. Analysis shows that the choice of the coupling coefficients relies on the bound of the chaotic system. Secondly, the nonlinearly coupled synchronization is studied; a sufficient condition for the locally asymptotical synchronization is derived, which is independent of the bound of the hyperchaotic system. Finally, numerical simulations are included to verify the effectiveness and feasibility of the developed theorems

  20. Validation of the National Aeronautics and Space Administration Task Load Index as a tool to evaluate-the learning curve for endoscopy training

    Science.gov (United States)

    Mohamed, Rachid; Raman, Maitreyi; Anderson, John; McLaughlin, Kevin; Rostom, Alaa; Coderre, Sylvain

    2014-01-01

    BACKGROUND: Although workplace workload assessments exist in different fields, an endoscopy-specific workload assessment tool is lacking. OBJECTIVE: To validate such a workload tool and use it to map the progression of novice trainees in gastroenterology in performing their first endoscopies. METHODS: The National Aeronautics and Space Administration Task Load Index (NASA-TLX) workload assessment tool was completed by eight novice trainees in gastroenterology and 10 practicing gastroenterologists/surgeons. An exploratory factor analysis was performed to construct a streamlined endoscopy-specific task load index, which was subsequently validated. The ‘Endoscopy Task Load Index’ was used to monitor progression of trainee exertion and self-assessed performance over their first 40 procedures. RESULTS: From the factor analysis of the NASA-TLX, two principal components emerged: a measure of exertion and a measure of self-efficacy. These items became the components of the newly validated Endoscopy Task Load Index. There was a steady decline in self-perceived exertion over the training period, which was more rapid for gastroscopy than colonoscopy. The self-efficacy scores for gastroscopy rapidly increased over the first few procedures, reaching a plateau after this period of time. For colonoscopy, there was a progressive increase in reported self-efficacy over the first three quartiles of procedures, followed by a drop in self-efficacy scores over the final quartile. DISCUSSION: The present study validated an Endoscopy Task Load Index that can be completed in <1 min. Practical implications of such a tool in endoscopy education include identifying periods of higher perceived exertion among novice endoscopists, facilitating appropriate levels of guidance from trainers. PMID:24619638

  1. Wireless Capsule Endoscopy Detects Meckel’s Diverticulum in a Child with Unexplained Intestinal Blood Loss

    Directory of Open Access Journals (Sweden)

    I. Xinias

    2012-10-01

    Full Text Available Meckel’s diverticulum (MD is the most common congenital anomaly of the gastrointestinal (GI tract, affecting about 2% of the population. Most cases of Meckel’s diverticula are asymptomatic. The diagnosis of symptomatic MD is often difficult to make. We report the case of an 8-year-old boy who presented with GI bleeding due to MD. The diagnostic difficulties after an initial negative endoscopic evaluation and the diagnostic value of the various endoscopic procedures are discussed. The patient had suffered from bright red stools for 20 h before hospital admission. GI scintigraphy with 99mTc-Na-pertechnetate was negative for heterotopic gastric tissue in the small bowel area. Colonoscopy performed in order to exclude Crohn’s disease was also negative. He was placed on ranitidine at a dose of 6 mg/kg body weight twice daily. The patient remained asymptomatic over a period of 6 months before he was readmitted due to macroscopic rectal bleeding. Upper endoscopy and colonoscopy used to investigate the source of bleeding showed normal macroscopic findings. Radiolabeling of blood constituents with 99mTc on delayed imaging showed radionucleotide concentration in the ascending and transverse colon suggestive of a lesion in the ileocecal area. Further investigation with the use of wireless capsule endoscopy revealed a MD. Wireless capsule endoscopy may thus be indicated for patients with GI blood loss when other diagnostic methods, such as upper and lower endoscopy and colonoscopy, have failed to identify the source of bleeding.

  2. The role of capnography in endoscopy patients undergoing nurse-administered propofol sedation

    DEFF Research Database (Denmark)

    Slagelse, Charlotte; Vilmann, Peter; Hornslet, Pernille

    2013-01-01

    . The existing literature on capnography for endoscopy patients sedated with nurse-administered propofol sedation (NAPS) is limited. Can the addition of capnography to standard monitoring during endoscopy with NAPS reduce the number, duration, and level of hypoxia. Materials and methods. This study...... capnography, were included in the analysis. The number and total duration of hypoxia was reduced by 39.3% and 21.1% in the intervention group compared to the control group (p > 0.05). No differences in actions taken against insufficient respiration were found. Changes in end-tidal carbon dioxide (R = 0.177, p......-value 0.05). Capnography is able to detect insufficient respiration that may lead to hypoxia prior to changes in pulse oximetry. However, due to a limited clinical benefit and additional costs associated with capnography, we do not find capnography necessary during the use of NAPS....

  3. Compiling a Bidirectional Dictionary Bridging English and the Sotho ...

    African Journals Online (AJOL)

    rbr

    bi-directional Sesotho sa Leboa ↔ Sesotho, Sesotho sa Leboa ↔ Setswana and ... example, the 100 most frequently used words in Sesotho sa Leboa in ranking .... Consider in this regard a selection of such mutual lexical items with high.

  4. Role of an ER stress response element in regulating the bidirectional promoter of the mouse CRELD2 - ALG12 gene pair

    Directory of Open Access Journals (Sweden)

    Hirata Yoko

    2010-11-01

    Full Text Available Abstract Background Recently, we identified cysteine-rich with EGF-like domains 2 (CRELD2 as a novel endoplasmic reticulum (ER stress-inducible gene and characterized its transcriptional regulation by ATF6 under ER stress conditions. Interestingly, the CRELD2 and asparagine-linked glycosylation 12 homolog (ALG12 genes are arranged as a bidirectional (head-to-head gene pair and are separated by less than 400 bp. In this study, we characterized the transcriptional regulation of the mouse CRELD2 and ALG12 genes that is mediated by a common bidirectional promoter. Results This short intergenic region contains an ER stress response element (ERSE sequence and is well conserved among the human, rat and mouse genomes. Microarray analysis revealed that CRELD2 and ALG12 mRNAs were induced in Neuro2a cells by treatment with thapsigargin (Tg, an ER stress inducer, in a time-dependent manner. Other ER stress inducers, tunicamycin and brefeldin A, also increased the expression of these two mRNAs in Neuro2a cells. We then tested for the possible involvement of the ERSE motif and other regulatory sites of the intergenic region in the transcriptional regulation of the mouse CRELD2 and ALG12 genes by using variants of the bidirectional reporter construct. With regards to the promoter activities of the CRELD2-ALG12 gene pair, the entire intergenic region hardly responded to Tg, whereas the CRELD2 promoter constructs of the proximal region containing the ERSE motif showed a marked responsiveness to Tg. The same ERSE motif of ALG12 gene in the opposite direction was less responsive to Tg. The direction and the distance of this motif from each transcriptional start site, however, has no impact on the responsiveness of either gene to Tg treatment. Additionally, we found three putative sequences in the intergenic region that antagonize the ERSE-mediated transcriptional activation. Conclusions These results show that the mouse CRELD2 and ALG12 genes are arranged as a

  5. 10 Gb/s bidirectional single fibre long reach PON link with distributed Raman amplification

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso; Kjær, Rasmus; Jeppesen, Palle

    2006-01-01

    We report operation of a single fibre bidirectional 80 km long reach PON link with symmetric up- and-downstream data rate of 10 Gb/s supported by distributed Raman fibre amplification only.......We report operation of a single fibre bidirectional 80 km long reach PON link with symmetric up- and-downstream data rate of 10 Gb/s supported by distributed Raman fibre amplification only....

  6. Günther Tulip inferior vena cava filter retrieval using a bidirectional loop-snare technique.

    Science.gov (United States)

    Ross, Jordan; Allison, Stephen; Vaidya, Sandeep; Monroe, Eric

    2016-01-01

    Many advanced techniques have been reported in the literature for difficult Günther Tulip filter removal. This report describes a bidirectional loop-snare technique in the setting of a fibrin scar formation around the filter leg anchors. The bidirectional loop-snare technique allows for maximal axial tension and alignment for stripping fibrin scar from the filter legs, a commonly encountered complication of prolonged dwell times.

  7. Use of asymmetric bidirectional catheters with different curvature radius for catheter ablation of cardiac arrhythmias.

    Science.gov (United States)

    Mantziari, Lilian; Suman-Horduna, Irina; Gujic, Marko; Jones, David G; Wong, Tom; Markides, Vias; Foran, John P; Ernst, Sabine

    2013-06-01

    The impact of recently introduced asymmetric bidirectional ablation catheters on procedural parameters and acute success rates of ablation procedures is unknown. We retrospectively analyzed data regarding ablations using a novel bidirectional catheter in a tertiary cardiac center and compared these in 1:5 ratio with a control group of procedures matched for age, gender, operator, and ablation type. A total of 50 cases and 250 controls of median age 60 (50-68) years were studied. Structural heart disease was equally prevalent in both groups (39%) while history of previous ablations was more common in the study arm (54% vs 30%, P = 0.001). Most of the ablation cases were for atrial fibrillation (46%), followed by atrial tachycardia (28%), supraventricular tachycardia (12%), and ventricular tachycardia (14%). Median procedure duration was 128 (52-147) minutes with the bidirectional, versus 143 (105-200) minutes with the conventional catheter (P = 0.232), and median fluoroscopy time was 17 (10-34) minutes versus 23 (12-39) minutes, respectively (P = 0.988). There was a trend toward a lower procedure duration for the atrial tachycardia ablations, 89 (52-147) minutes versus 130 (100-210) minutes, P = 0.064. The procedure was successfully completed in 96% of the bidirectional versus 84% of the control cases (P = 0.151). A negative correlation was observed between the relative fluoroscopy duration and the case number (r = -0.312, P = 0.028), reflecting the learning curve for the bidirectional catheter. The introduction of the bidirectional catheter resulted in no prolongation of procedure parameters and similar success rates, while there was a trend toward a lower procedure duration for atrial tachycardia ablations. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  8. Diagnosis of Helicobacter pylori-related chronic gastritis, gastric adenoma and early gastric cancer by magnifying endoscopy.

    Science.gov (United States)

    Soma, Nei

    2016-10-01

    Evaluating the prevalence and severity of gastritis by endoscopy is useful for estimating the risk of gastric cancer (GC). Moreover, understanding the endoscopic appearances of gastritis is important for diagnosing GC due to the fact that superficial mucosal lesions mimicing gastritis (gastritis-like lesions) are quite difficult to be detected even with optimum preparation and the best technique, and in such cases tissue biopsy is often not very accurate for the diagnosis of gastric epithelial neoplasia. Magnifying endoscopy is a highly accurate technique for the detection of early gastric cancer (EGC). Recent reports have described that various novel endoscopic markers which, visualized by magnifying endoscopy with image-enhanced system (ME-IEE), can predict specific histopathological findings. Using ME-IEE with vessels and surface classification system (VSCS) may represent an excellent diagnostic performance with high confidence and good reproducibility to the endoscopists if performed under consistent conditions, including observation under maximal magnification. The aim of this review was to discuss how to identify high-risk groups for GC by endoscopy, and how to detect effectively signs of suspicious lesions by conventional white light imaging (C-WLI) or chromoendoscopy (CE). Furthermore, to characterize suspicious lesions using ME-IEE using the criteria and classification of EGC based upon VSCS. © 2016 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  9. Baby Shampoo versus Commercial Anti-fogging Solution to Prevent Fogging during Nasal Endoscopy: A Randomized Double-Blinded, Matched-Pair, Equivalent Trial.

    Science.gov (United States)

    Chainansamit, Seksun; Piromchai, Patorn; Anantpinijwatna, Intira; Kasemsiri, Pornthep; Thanaviratananich, Sanguansak

    2015-08-01

    To compare the minimization of the fog condensation during nasal endoscopy between a commercial anti-fogging agent and baby shampoo. This randomized double-blinded matched pair study was conducted at the Department of Otorhinolaryngology, Faculty of Medicine, Khon Kaen University during February 4, 2013 to March 14, 2013. The commercial anti-fogging solution (Ultrastop®) and baby shampoo solution (Johnson's® no more tear®) were compared. A computer generated randomization was performed to select the solution applying on the lens for nasal endoscopy of the right nasal cavity. The other solution was then used for the left one. Three passes of endoscopy were performed to examine the floor of the nose, the sphenoethmoidal recess and the middle meatus area which spent about 30 seconds for each time of endoscopy. The time to become foggy on the lens and the preferred solution assessed by the endoscopists were recorded. There were 71 eligible patients recruited in the study, 37 males (52.1%) and 34 females (47.9%). There was no fogging during a 30-second nasal endoscopy either by baby shampoo or commercial anti-fogging solution. However, 9.86% (95% C12.75-16.97) of endoscopists preferred commercial anti-fogging agent, 7.04% (95% CI 0.94-13.14) preferred baby shampoo and 83.10% (95% CI 74.16-92.03) had equal satisfaction. Both agents had no statistically significant difference for preventing foggy on the lens. Baby shampoo is an effective agent to prevent fogging during nasal endoscopy and comparable with the commercial anti-fogging agent.

  10. Parenting and Children's Externalizing Behavior: Bidirectionality during Toddlerhood

    Science.gov (United States)

    Verhoeven, Marjolein; Junger, Marianne; van Aken, Chantal; Dekovic, Maja; van Aken, Marcel A. G.

    2010-01-01

    This study examined the bidirectional relationship between parenting and boys' externalizing behaviors in a four-wave longitudinal study of toddlers. Participants were 104 intact two-parent families with toddler sons. When their sons were 17, 23, 29, and 35 months of age, mothers and fathers reported on a broad range of parenting dimensions…

  11. Cellular Mechanisms Underlying Behavioral State-Dependent Bidirectional Modulation of Motor Cortex Output

    Directory of Open Access Journals (Sweden)

    Julia Schiemann

    2015-05-01

    Full Text Available Neuronal activity in primary motor cortex (M1 correlates with behavioral state, but the cellular mechanisms underpinning behavioral state-dependent modulation of M1 output remain largely unresolved. Here, we performed in vivo patch-clamp recordings from layer 5B (L5B pyramidal neurons in awake mice during quiet wakefulness and self-paced, voluntary movement. We show that L5B output neurons display bidirectional (i.e., enhanced or suppressed firing rate changes during movement, mediated via two opposing subthreshold mechanisms: (1 a global decrease in membrane potential variability that reduced L5B firing rates (L5Bsuppressed neurons, and (2 a coincident noradrenaline-mediated increase in excitatory drive to a subpopulation of L5B neurons (L5Benhanced neurons that elevated firing rates. Blocking noradrenergic receptors in forelimb M1 abolished the bidirectional modulation of M1 output during movement and selectively impaired contralateral forelimb motor coordination. Together, our results provide a mechanism for how noradrenergic neuromodulation and network-driven input changes bidirectionally modulate M1 output during motor behavior.

  12. Bi-directional Reflectance of Icy Surface Analogs: A Dual Approach

    Science.gov (United States)

    Quinones, Juan Manuel; Vides, Christina; Nelson, Robert M.; Boryta, Mark; Mannat, Ken s.

    2018-01-01

    Bi-directional reflectance measurements of analogs for planetary regolith have provided insight into the surface properties of planetary satellites and small bodies. Because Aluminum Oxide (Al2O3) and water ice share a similar hexagonal crystalline structure, the former has been used in laboratory experiments to simulate the regolith of both icy and dusty planetary bodies. By measuring various sizes of well sorted size fractions of Al2O3, the reflectance phase curve and porosity of a planetary regolith can be determined. We have designed an experiment to test the laboratory measurements produced by Nelson et al. (2000). Additionally, we made reflectance measurements for other alkali-halide compounds that could be used for applications beyond astronomy and planetary science.In order to provide an independent check on the Nelson et al. data, we designed an instrument with a different configuration. While both instruments take bidirectional reflectance measurements, our instrument, the Rigid Photometric Goniometer (RPG), is fixed at a phase angle of 5° and detects the scattered light with a photomultiplier tube (PMT). The PMT current is then measured with an electrometer. Following the example of Nelson et al., we measured the bidirectional reflectance of Al2O3 particulate size fractions between 0.1sizes from 20size that provided optimal, or maximum, reflectance for each compound. Our conclusions bring confirmation and clarity to photometric sciences.

  13. Performance Analysis of Video PHY Controller Using Unidirection and Bi-directional IO Standard via 7 Series FPGA

    DEFF Research Database (Denmark)

    Das, Bhagwan; Abdullah, M F L; Hussain, Dil muhammed Akbar

    2017-01-01

    graphics consumes more power, this creates a need of designing the low power design for Video PHY controller. In this paper, the performance of Video PHY controller is analyzed by comparing the power consumption of unidirectional and bi-directional IO Standard over 7 series FPGA. It is determined...... that total on-chip power is reduced for unidirectional IO Standard based Video PHY controller compared to bidirectional IO Standard based Video PHY controller. The most significant achievement of this work is that it is concluded that unidirectional IO Standard based Video PHY controller consume least...... standby power compared to bidirectional IO Standard based Video PHY controller. It is defined that for 6 GHz operated frequency Video PHY controller, the 32% total on-chip power is reduced using unidirectional IO Standard based Video PHY controller is less compared to bidirectional IO Standard based Video...

  14. Bidirectional Barbed Sutures for Wound Closure: Evolution and Applications

    Science.gov (United States)

    Paul, Malcolm D.

    2009-01-01

    Traditionally, wound closure sutures have in common the need to tie knots with the inherent risk of extrusion, palpability, microinfarcts, breakage, and slippage. Bidirectional barbed sutures have barbs arrayed in a helical fashion in opposing directions on either side of an unbarbed midsegment. This suture is inserted at the midpoint of a wound and pulled through till resistance is encountered from the opposing barbs; each half of the suture is then advanced to the lateral ends of the wound. This design provides a method of evenly distributing tension along the incision line, a faster suture placement and closure time with no need to tie knots, and the possibility of improved cosmesis. Bidirectional barbed sutures, which are available in both absorbable and nonabsorbable forms, can be used for simple closures, multilayered closures, and closure of high-tension wounds in a variety of surgical settings. PMID:24527114

  15. Bidirectional fiber-wireless and fiber-VLLC transmission system based on an OEO-based BLS and a RSOA.

    Science.gov (United States)

    Lu, Hai-Han; Li, Chung-Yi; Lu, Ting-Chien; Wu, Chang-Jen; Chu, Chien-An; Shiva, Ajay; Mochii, Takao

    2016-02-01

    A bidirectional fiber-wireless and fiber-visible-laser-light-communication (VLLC) transmission system based on an optoelectronic oscillator (OEO)-based broadband light source (BLS) and a reflective semiconductor optical amplifier (RSOA) is proposed and experimentally demonstrated. Through an in-depth observation of such bidirectional fiber-wireless and fiber-VLLC transmission systems, good bit error rate performances are obtained over a 40 km single-mode fiber and a 10 m RF/optical wireless transport. Such a bidirectional fiber-wireless and fiber-VLLC transmission system is an attractive option for providing broadband integrated services.

  16. TU-H-CAMPUS-TeP1-04: Novel 3D Printed Plastic Cutouts Filled with Aluminum Oxide for Same Day Electron Radiotherapy

    International Nuclear Information System (INIS)

    Mikell, J; Lee, C; Lam, K

    2016-01-01

    Purpose: Clinics that outsource electron cutout manufacturing may be unable to simulate and treat patients on the same day. To enable same day treatment, we investigate the use of 3D printed hollow cutouts filled with 30 grit Al_2O_3 powder. We verified the dosimetric equivalence of such a cutout relative to an outsourced Copper cutout. Methods: Printing was performed using a Ultibots Kossel 250 V-Slot 3D printer and polylactic acid filament. Printing files were derived from an in-house 3D model designed to mate with a Varian 6 cm electron cone. Relative to conventional cutouts (Copper or Cerrobend), the height of the hollow plastic cutout was extended by 1.0 cm to increase attenuation. Measurements were performed for 6 MeV in solid water at dmax (1.4 cm) with Gafchromic™ EBT3 film; the cutout was kidney-shaped with a long and short axis of approximately 5 and 2 cm, respectively. The Copper cutout was based on an outline of the 3D printed cutout.A calibration film was exposed immediately after the electron irradiations. All films, including an un-irradiated one, were from the same batch. Films were scanned on an Epson 10000XL flatbed scanner. Film analysis was performed in DoseLab (MOBIUS Medical Systems, Houston, Tx). Results: Visual comparison of the physical cutouts revealed that the Copper cutout had a slightly smaller opening than the printed cutout. Line profiles through the registered films indicated agreement within 5% in the open section. 99.9% of pixels passed gamma analysis with 2% local percent difference, 2 mm DTA, and a 25% threshold. Conclusion: Same day simulation and treatment with electrons is feasible with 3D printing of a hollow cutout filled with Al_2O_3. Future work will include evaluations of additional cutout shapes at different depths for higher energies. Other printing materials, such as bismuth, are being tested.

  17. TU-H-CAMPUS-TeP1-04: Novel 3D Printed Plastic Cutouts Filled with Aluminum Oxide for Same Day Electron Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mikell, J; Lee, C; Lam, K [University of Michigan Health Systems, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: Clinics that outsource electron cutout manufacturing may be unable to simulate and treat patients on the same day. To enable same day treatment, we investigate the use of 3D printed hollow cutouts filled with 30 grit Al{sub 2}O{sub 3} powder. We verified the dosimetric equivalence of such a cutout relative to an outsourced Copper cutout. Methods: Printing was performed using a Ultibots Kossel 250 V-Slot 3D printer and polylactic acid filament. Printing files were derived from an in-house 3D model designed to mate with a Varian 6 cm electron cone. Relative to conventional cutouts (Copper or Cerrobend), the height of the hollow plastic cutout was extended by 1.0 cm to increase attenuation. Measurements were performed for 6 MeV in solid water at dmax (1.4 cm) with Gafchromic™ EBT3 film; the cutout was kidney-shaped with a long and short axis of approximately 5 and 2 cm, respectively. The Copper cutout was based on an outline of the 3D printed cutout.A calibration film was exposed immediately after the electron irradiations. All films, including an un-irradiated one, were from the same batch. Films were scanned on an Epson 10000XL flatbed scanner. Film analysis was performed in DoseLab (MOBIUS Medical Systems, Houston, Tx). Results: Visual comparison of the physical cutouts revealed that the Copper cutout had a slightly smaller opening than the printed cutout. Line profiles through the registered films indicated agreement within 5% in the open section. 99.9% of pixels passed gamma analysis with 2% local percent difference, 2 mm DTA, and a 25% threshold. Conclusion: Same day simulation and treatment with electrons is feasible with 3D printing of a hollow cutout filled with Al{sub 2}O{sub 3}. Future work will include evaluations of additional cutout shapes at different depths for higher energies. Other printing materials, such as bismuth, are being tested.

  18. Primary Parallel Isolated Boost Converter with Bidirectional Operation

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Mira Albert, Maria del Carmen; Sen, Gökhan

    2012-01-01

    This paper presents a bidirectional dc/dc converter operated with batteries both in the input and output. Primary parallel isolated boost converter (PPIBC) with transformer series connection on the high voltage side is preferred due to its ability to handle high currents in the low voltage side. ...... and output battery banks with a defined ramp....

  19. Combined high-field intraoperative magnetic resonance imaging and endoscopy increase extent of resection and progression-free survival for pituitary adenomas

    Science.gov (United States)

    Sylvester, Peter T.; Evans, John A.; Zipfel, Gregory J.; Chole, Richard A.; Uppaluri, Ravindra; Haughey, Bruce H.; Getz, Anne E.; Silverstein, Julie; Rich, Keith M.; Kim, Albert H.; Dacey, Ralph G.

    2014-01-01

    Purpose The clinical benefit of combined intraoperative magnetic resonance imaging (iMRI) and endoscopy for transsphenoidal pituitary adenoma resection has not been completely characterized. This study assessed the impact of microscopy, endoscopy, and/or iMRI on progression-free survival, extent of resection status (gross-, near-, and subtotal resection), and operative complications. Methods Retrospective analyses were performed on 446 transsphenoidal pituitary adenoma surgeries at a single institution between 1998 and 2012. Multivariate analyses were used to control for baseline characteristics, differences during extent of resection status, and progression-free survival analysis. Results Additional surgery was performed after iMRI in 56/156 cases (35.9 %), which led to increased extent of resection status in 15/156 cases (9.6 %). Multivariate ordinal logistic regression revealed no increase in extent of resection status following iMRI or endoscopy alone; however, combining these modalities increased extent of resection status (odds ratio 2.05, 95 % CI 1.21–3.46) compared to conventional transsphenoidal microsurgery. Multivariate Cox regression revealed that reduced extent of resection status shortened progression-free survival for near- versus gross-total resection [hazard ratio (HR) 2.87, 95 % CI 1.24–6.65] and sub- versus near-total resection (HR 2.10; 95 % CI 1.00–4.40). Complication comparisons between microscopy, endoscopy, and iMRI revealed increased perioperative deaths for endoscopy versus microscopy (4/209 and 0/237, respectively), but this difference was non-significant considering multiple post hoc comparisons (Fisher exact, p = 0.24). Conclusions Combined use of endoscopy and iMRI increased pituitary adenoma extent of resection status compared to conventional transsphenoidal microsurgery, and increased extent of resection status was associated with longer progression-free survival. Treatment modality combination did not significantly impact

  20. The evidence of apelin has the bidirectional effects on feeding regulation in Siberian sturgeon (Acipenser baerii).

    Science.gov (United States)

    Hao, Jin; Liu, Qing; Zhang, Xin; Wu, Yuanbing; Zhu, Jieyao; Qi, Jinwen; Tang, Ni; Wang, Shuyao; Wang, Hong; Chen, Defang; Li, Zhiqiong

    2017-08-01

    Apelin is a peptide, mainly produced in the brain, which participates in several physiologic effects. However, knowledge about the mechanism of appetite regulation in teleosts, including the role of apelin is not well understood. The aim of this study is to explore the effect of feeding status on the expression of apelin mRNA in the whole brain and the effects of injection of apelin on food intake in Siberian sturgeon (Acipenser baerii). In this study, we first cloned the apelin cDNA sequence of the Siberian sturgeon. We obtained a 1046-bp cDNA fragment, including a 237-bp open reading frame (ORF) that encoded 78 amino acids. Apelin was widely distributed in 11 tissues related to feeding regulation, with the highest expression in thewhole brain, followed by the spleen and trunk kidney. In addition, we measured the effects of periprandial (preprandial and postprandial) change, fasting and re-feeding on apelin mRNA expression in whole brain. The level of apelin mRNA was significantly decreased 1h after feeding. The results of the fasting experiment showed that the expression of apelin mRNA in the brain was significantly reduced after 1day of fasting but consistently increased throughout the 15-day food deprivation period. When the 15-day fasted fish were re-fed, apelin mRNA expression in the brain was significantly increased as compared to that of the control. These results suggest that apelin may play a bidirectional role in the regulation of food intake in the Siberian sturgeon. In order to further examine the effect of apelin on feeding regulation in Siberian sturgeons, acute and chronic intraperitoneal (i.p.) injection experiments were performed and food intakes were recorded. Results showed that acute i.p. injection of apelin-13 reduced food intake, however, chronic i.p. injection apelin-13 increased the food intake for 7days in Siberian sturgeons. In conclusion, our results show that apelin has a bidirectional effect on feeding regulation in Siberian sturgeons

  1. Bidirectional Relationships Between Parenting Processes and Deviance in a Sample of Inner-City African American Youth

    Science.gov (United States)

    Harris, Charlene; Vazsonyi, Alexander T.; Bolland, John M.

    2016-01-01

    The current study assessed for bidirectional relationships among supportive parenting (knowledge), negative parenting (permissiveness), and deviance in a sample (N = 5,325) of poor, inner-city African American youth from the Mobile Youth Survey (MYS) over 4 years. Cross-lagged path analysis provided evidence of significant bidirectional paths among parenting processes (knowledge and permissiveness) and deviance over time. Follow-up multigroup tests provided only modest evidence of dissimilar relationships by sex and by developmental periods. The findings improve our understanding of developmental changes between parenting behaviors and deviance during adolescence and extended current research of the bidirectionality of parent and child relationships among inner-city African American youth. PMID:28316460

  2. Analysis of Bi-directional Effects on the Response of a Seismic Base Isolation System

    International Nuclear Information System (INIS)

    Park, Hyung-Kui; Kim, Jung-Han; Kim, Min Kyu; Choi, In-Kil

    2014-01-01

    The floor response spectrum depends on the height of the floor of the structure. Also FRS depends on the characteristics of the seismic base isolation system such as the natural frequency, damping ratio. In the previous study, the floor response spectrum of the base isolated structure was calculated for each axis without considering bi-directional effect. However, the shear behavior of the seismic base isolation system of two horizontal directions are correlated each other by the bi-directional effects. If the shear behavior of the seismic isolation system changes, it can influence the floor response spectrum and displacement response of isolators. In this study, the analysis of a bi-directional effect on the floor response spectrum was performed. In this study, the response of the seismic base isolation system based on the bi-directional effects was analyzed. By analyzing the time history result, while there is no alteration in the maximum shear force of seismic base isolation system, it is confirmed that the shear force is generally more decreased in a one-directional that in a two-directional in most parts. Due to the overall decreased shear force, the floor response spectrum is more reduced in a two-directional than in a one-directional

  3. Usefulness of Double-Balloon Endoscopy in the Postoperative Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    Masaki Endo

    2011-01-01

    Full Text Available Background. The small intestine has been considered to be a highly difficult organ to visualize in imaging examinations due to its anatomical location compared with the stomach and the colon. In recent years, many imaging modalities have become available, such as CT enterography, MR enterography, capsule endoscopy (CE, and double-balloon endoscopy (DBE. Patients and Methods. DBE was performed in the postoperative intestines of 91 patients (128 DBE examinations at Iwate Medical University between 2004 and 2010. There were 61 male and 30 female patients, and their mean age was 69.7 years (range: 30–80 years. Results. A total of 124 DBE examinations were performed with endoscope insertion into the reconstructed intestines. The endoscope reached the blind end in 115 of 124 examinations, (92.7%. There were 17 patients with obscure gastrointestinal bleeding in whom 30 DBE examinations were performed. The bleeding site was identified in 12 patients (70.6%. Nine patients underwent endoscopic treatment. Hemostasis was achieved in all patients. Conclusion. DBE is very useful modality for the assessment and application of endotherapy to areas of the small bowel which have been altered by surgery.

  4. Correcting Bidirectional Effects in Remote Sensing Reflectance from Coastal Waters

    Science.gov (United States)

    Stamnes, K. H.; Fan, Y.; Li, W.; Voss, K. J.; Gatebe, C. K.

    2016-02-01

    Understanding bidirectional effects including sunglint is important for GEO-CAPE for several reasons: (i) correct interpretation of ocean color data; (ii) comparing consistency of spectral radiance data derived from space observations with a single instrument for a variety of illumination and viewing conditions; (iii) merging data collected by different instruments operating simultaneously. We present a new neural network (NN) method to correct bidirectional effects in water-leaving radiance for both Case 1 and Case 2 waters. We also discuss a new BRDF and 2D sun-glint model that was validated by comparing simulated surface reflectances with Cloud Absorption Radiometer (CAR) data. Finally, we present an extension of our marine bio-optical model to the UV range that accounts for the seasonal dependence of the inherent optical properties (IOPs).

  5. A new setup to measure bidirectional reflectance distribution functions

    NARCIS (Netherlands)

    Roosjen, P.P.J.; Clevers, J.G.P.W.; Bartholomeus, H.

    2012-01-01

    The Plant Facility, a new laboratory goniometer system, built by the Wageningen University has been tested in order to take bidirectional reflectance distribution function (BRDF) measurements. An ASD FieldSpec 3 spectroradiometer mounted on an industrial robot arm is able to measure small targets

  6. Optical properties (bidirectional reflectance distribution function) of shot fabric

    NARCIS (Netherlands)

    Lu, Rong; Koenderink, Jan J.; Kappers, Astrid M L

    2000-01-01

    To study the optical properties of materials, one needs a complete set of the angular distribution functions of surface scattering from the materials. Here we present a convenient method for collecting a large set of bidirectional reflectance distribution function (BRDF) samples in the hemispherical

  7. Bidirectional current-voltage converters based on magnetostrictive/piezoelectric composites

    NARCIS (Netherlands)

    Jia, Y.; Or, S.W.; Chan, H.L.W.; Jiao, J.; Luo, H.; Van der Zwaag, S.

    2009-01-01

    We report a power supply-free, bidirectional electric current-voltage converter based on a coil-wound laminated composite of magnetostrictive alloy and piezoelectric crystal. An electric current applied to the coil induces a magnetic field, resulting in an electric voltage from the composite due to

  8. Isolated Bidirectional DC–DC Converter for SuperCapacitor Applications

    DEFF Research Database (Denmark)

    Dehnavi, Sayed M. D.; Sen, Gökhan; Thomsen, Ole Cornelius

    2011-01-01

    This paper proposes a new bidirectional DC/DC converter for supercapacitor applications. The proposed converter has a parallel structure in supercapacitor side (where voltage is low and current is high) and a series structure in the other side. This structure increases efficiency of the converter...

  9. Videofluoroscopy versus upper G.I. endoscopy: A comparative study as a diagnostic tool in patients presenting with dysphagia

    OpenAIRE

    Sharwak Ramlan; Sai Manohar; Gangadhara Somayaji

    2015-01-01

    Background and Objective: Dysphagia is a major symptom in many of the patients coming to the hospital. There can be various causes of dysphagia and its accurate diagnosis shows the way for the necessary treatment. Videofluoroscopy and upper gastrointestinal (GI) endoscopy are the two most commonly employed primary investigating modalities in assessing dysphagia. The objective of the study was to compare videofluoroscopy and upper GI endoscopy and establish a primary diagnostic tool for assess...

  10. The Clinical Risks of Infection Associated with Endoscopy

    Directory of Open Access Journals (Sweden)

    Alistair E Cowen

    2001-01-01

    Full Text Available The cleaning of flexible endoscopes is difficult and time consuming. Any method of attempted sterilization or high level disinfection will fail if prior cleaning has been defective. Inadequate reprocessing of endoscopes may result in patient to patient transmission of serious bacterial and viral diseases or infection with endemic hospital pathogens. Antibiotic prophylaxis is required to prevent septicemia and bacterial endocarditis in high risk patients undergoing specific endoscopic procedures. Prevention of serious endoscopy-associated clinical infections requires strict compliance with detailed reprocessing protocols by specially trained nursing staff.

  11. The OTSC®-clip in revisional endoscopy against weight gain after bariatric gastric bypass surgery.

    Science.gov (United States)

    Heylen, Alex Marie Florent; Jacobs, Anja; Lybeer, Monika; Prosst, Ruediger L

    2011-10-01

    The maintenance of the restrictive component of the Fobi pouch gastric bypass is essential for permanent weight control. Dilatation of the pouch-outlet and of the pouch itself is responsible for substantial weight gain by an increased volume per meal and binge-eating due to the rapid emptying. An endoscopic over-the-scope clip (OTSC®; Ovesco AG, Tübingen, Germany) was applied in 94 patients following gastric bypass and unintended weight gain by dilated gastro-jejunostomy to narrow the pouch-outlet. The OTSC®-clip application was safe and efficient to reduce the pouch-outlet in all cases. Best clinical results were obtained by narrowing the gastro-jejunostomy by placing two clips at opposite sites, hence reducing the outlet of more than 80%. Preferably, the clip approximated the whole thickness of the wall to avoid further dilatation of the anastomosis. Between surgery and OTSC®-clip application the mean BMI dropped from 45.8 (±3.6) to 32.8 (±1.9). At the first follow-up about 3 months (mean 118 days, ±46 days) after OTSC®-clip application the mean BMI was 29.7 (±1.8). At the second follow-up about 1 year (mean 352 days, ±66 days) after OTSC®-clip application the mean BMI was 27.4 (±3.8). The OTSC®-clip for revisional endoscopy after gastric bypass is reliable and effective in treating weight gain due to a dilated pouch-outlet with favorable short- and midterm results.

  12. Capsule endoscopy for the diagnosis and follow up of crohn’s disease

    DEFF Research Database (Denmark)

    Jensen, Michael Dam; Brodersen, Jacob; Kjeldsen, Jens

    2017-01-01

    Capsule endoscopy (CE) has revolutionized the diagnosis and monitoring of small bowel Crohn’s disease (CD). the procedure is patient friendly and noninvasive, and compared to cross-sectional imaging, CE allows a direct and detailed evaluation of the entire small bowel mucosa witha high sensitivit...

  13. Correlation between predicted and actual consequences of capsule endoscopy on patient management

    NARCIS (Netherlands)

    Westerhof, J.; Weersma, R. K.; Thijs, W. J.; Limburg, A. J.; Koornstra, J. J.; de Graaf, A.P.

    Background. Capsule endoscopy (CE) is a relatively new diagnostic modality in the evaluation of patients with suspected small bowel pathology. It is unclear to what extent physicians are able to predict the clinical consequences of CE on patient management. Methods. In this prospective study, 180

  14. Deadbeat control of power leveling unit with bidirectional buck/boost DC/DC converter

    OpenAIRE

    Hamasaki, Shin-ichi; Mukai, Ryosuke; Yano, Yoshihiro; Tsuji, Mineo

    2014-01-01

    As a distributed generation system increases, a stable power supply becomes difficult. Thus control of power leveling (PL) unit is required to maintain the balance of power flow for irregular power generation. The unit is required to respond to change of voltage and bidirectional power flow. So the bidirectional buck/boost DC/DC converter is applied for the control of PL unit in this research. The PL unit with Electric double-layer capacitor (EDLC) is able to absorb change of power, and it is...

  15. Finite-Time Stability for Fractional-Order Bidirectional Associative Memory Neural Networks with Time Delays

    International Nuclear Information System (INIS)

    Xu Chang-Jin; Li Pei-Luan; Pang Yi-Cheng

    2017-01-01

    This paper is concerned with fractional-order bidirectional associative memory (BAM) neural networks with time delays. Applying Laplace transform, the generalized Gronwall inequality and estimates of Mittag–Leffler functions, some sufficient conditions which ensure the finite-time stability of fractional-order bidirectional associative memory neural networks with time delays are obtained. Two examples with their simulations are given to illustrate the theoretical findings. Our results are new and complement previously known results. (paper)

  16. Protein remote homology detection based on bidirectional long short-term memory.

    Science.gov (United States)

    Li, Shumin; Chen, Junjie; Liu, Bin

    2017-10-10

    Protein remote homology detection plays a vital role in studies of protein structures and functions. Almost all of the traditional machine leaning methods require fixed length features to represent the protein sequences. However, it is never an easy task to extract the discriminative features with limited knowledge of proteins. On the other hand, deep learning technique has demonstrated its advantage in automatically learning representations. It is worthwhile to explore the applications of deep learning techniques to the protein remote homology detection. In this study, we employ the Bidirectional Long Short-Term Memory (BLSTM) to learn effective features from pseudo proteins, also propose a predictor called ProDec-BLSTM: it includes input layer, bidirectional LSTM, time distributed dense layer and output layer. This neural network can automatically extract the discriminative features by using bidirectional LSTM and the time distributed dense layer. Experimental results on a widely-used benchmark dataset show that ProDec-BLSTM outperforms other related methods in terms of both the mean ROC and mean ROC50 scores. This promising result shows that ProDec-BLSTM is a useful tool for protein remote homology detection. Furthermore, the hidden patterns learnt by ProDec-BLSTM can be interpreted and visualized, and therefore, additional useful information can be obtained.

  17. Effect of particle nonsphericity on bidirectional reflectance of cirrus clouds

    Energy Technology Data Exchange (ETDEWEB)

    Mishchenko, M.I.; Rossow, W.B.; Macke, A.; Lacis, A.A. [Goddard Institute for Space Studies, New York, NY (United States)

    1996-04-01

    This paper describes the use of the fractal ice particle method to study the differences in bidirectional reflectance caused by the differences in the single scattering phase functions of spherical water droplets and nonspherical ice crystals.

  18. Prophylactic antibiotics for endoscopy-associated peritonitis in peritoneal dialysis patients.

    Directory of Open Access Journals (Sweden)

    Hsin-Hsu Wu

    Full Text Available INTRODUCTION: Continuous ambulatory peritoneal dialysis (CAPD peritonitis may develop after endoscopic procedures, and the benefit of prophylactic antibiotics is unclear. In the present study, we investigated whether prophylactic antibiotics reduce the incidence of peritonitis in these patients. PATIENTS AND METHODS: We retrospectively reviewed all endoscopic procedures, including esophagogastroduodenoscopy (EGD, colonoscopy, sigmoidoscopy, cystoscopy, hysteroscopy, and hysteroscopy-assisted intrauterine device (IUD implantation/removal, performed in CAPD patients at Chang Gung Memorial Hospital, Taiwan, between February 2001 and February 2012. RESULTS: Four hundred and thirty-three patients were enrolled, and 125 endoscopies were performed in 45 patients. Eight (6.4% peritonitis episodes developed after the examination. Antibiotics were used in 26 procedures, and none of the patients had peritonitis (0% vs. 8.1% without antibiotic use; p=0.20. The peritonitis rate was significantly higher in the non-EGD group than in the EGD group (15.9% [7/44] vs. 1.2% [1/81]; p<0.005. Antibiotic use prior to non-EGD examinations significantly reduced the endoscopy-associated peritonitis rate compared to that without antibiotic use (0% [0/16] vs. 25% [7/28]; p<0.05. Peritonitis only occurred if invasive procedures were performed, such as biopsy, polypectomy, or IUD implantation, (noninvasive procedures, 0% [0/20] vs. invasive procedures, 30.4% [7/23]; p<0.05. No peritonitis was noted if antibiotics were used prior to examination with invasive procedures (0% [0/10] vs. 53.8% [7/13] without antibiotic use; p<0.05. Although not statistically significant, antibiotics may play a role in preventing gynecologic procedure-related peritonitis (antibiotics, 0% [0/4] vs. no antibiotics, 55.6% [5/9]; p=0.10. CONCLUSION: Antibiotic prophylaxis significantly reduced endoscopy-associated PD peritonitis in the non-EGD group. Endoscopically assisted invasive procedures, such

  19. Longitudinal Bidirectional Relations between Adolescents' Sympathy and Prosocial Behavior

    Science.gov (United States)

    Carlo, Gustavo; Padilla-Walker, Laura M.; Nielson, Matthew G.

    2015-01-01

    Despite the importance of understanding sympathy and prosocial behaviors, research on the development of these tendencies in adolescence remains relatively sparse. In the present study, we examined age trends and bidirectional longitudinal relations in sympathy and prosocial behaviors across early to middle adolescents. Participants were 500…

  20. [Design of extracorporeal apparatus of capsule endoscopy based on ARM+FPGA].

    Science.gov (United States)

    Wang, Shenghua; Zhang, Sijie; Wang, Yue; Wang, Zhenxing

    2011-10-01

    Considering that the patients would bear the annoyance of fixed posture for long time when they are examined with gastrointestinal wireless endoscopy, even though portable devices have been developed, the treatments still depend on PC so much, we proposed an embedded solution based on ARM + FPGA. It used embedded ARM9 S3C2440 as processor core, collected images from digestive tract through capsule endoscopy which can be swallowed down there, and wirelessly transferred these images to the receiving system, then used video decoder chip SAA7114H for analog of NTSC video image decode. And under FPGA's logic controlling, effective digital video signal was transferred to S3C2440 for further treatment. Finally within the embedded Linux environment, we programmed the visual user interfaces using the QT/Embedded, realizing the offline record of the real-time video images of digestive tract portable and preferences. It can make patients move more freely and even without PC when examining. In addition, the method greatly improves the efficiency of the doctor, and is more intelligent and with more humane nature.

  1. Evaluation of complex gonioapparent samples using a bidirectional spectrometer.

    Science.gov (United States)

    Rogelj, Nina; Penttinen, Niko; Gunde, Marta Klanjšek

    2015-08-24

    Many applications use gonioapparent targets whose appearance depends on irradiation and viewing angles; the strongest effects are provided by light diffraction. These targets, optically variable devices (OVDs), are used in both security and authentication applications. This study introduces a bidirectional spectrometer, which enables to analyze samples with most complex angular and spectral properties. In our work, the spectrometer is evaluated with samples having very different types of reflection, concerning spectral and angular distributions. Furthermore, an OVD containing several different grating patches is evaluated. The device uses automatically adjusting exposure time to provide maximum signal dynamics and is capable of doing steps as small as 0.01°. However, even 2° steps for the detector movement showed that this device is more than capable of characterizing even the most complex reflecting surfaces. This study presents sRGB visualizations, discussion of bidirectional reflection, and accurate grating period calculations for all of the grating samples used.

  2. A Bidirectional Relationship between Conceptual Organization and Word Learning

    Directory of Open Access Journals (Sweden)

    Tanya Kaefer

    2013-01-01

    Full Text Available This study explores the relationship between word learning and conceptual organization for preschool-aged children. We proposed a bidirectional model in which increases in word learning lead to increases in taxonomic organization, which, in turn, leads to further increases in word learning. In order to examine this model, we recruited 104 4-year olds from Head Start classrooms; 52 children participated in a two-week training program, and 52 children were in a control group. Results indicated that children in the training program learned more words and were more likely to sort taxonomically than children in the control condition. Furthermore, the number of words learned over the training period predicted the extent to which children categorized taxonomically. Additionally, this ability to categorize taxonomically predicted the number of words learned outside the training program, over and above the number of words learned in the program. These results suggest a bi-directional relationship between conceptual organization and word learning.

  3. Portal hypertensive enteropathy diagnosed by capsule endoscopy and demonstration of the ileal changes after transjugular intrahepatic portosystemic shunt placement: a case report

    Directory of Open Access Journals (Sweden)

    Carella Alessandra

    2011-03-01

    Full Text Available Abstract Introduction Recent data suggest that mucosal abnormalities can occur even in the duodenum, jejunum, and distal ileum of cirrhosis patients. We present a case of portal hypertensive enteropathy in a cirrhosis patient shown by capsule endoscopy and the effect of transjugular intrahepatic portosystemic shunt on the ileal pictures. Case presentation An 83-year-old Caucasian woman was admitted to our hospital for anemia and a positive fecal occult blood test. An upper gastrointestinal endoscopy revealed small varices without bleeding signs and hypertensive gastropathy. Colonoscopy was negative. To rule out any other cause of bleeding, capsule endoscopy was performed; capsule endoscopy revealed severe hyperemia of the jejunum-ileal mucosa with active bleeding. Because of the persistence of anemia and the frequent blood transfusions, not responding to β-blocker drugs or octreotide infusion, a transjugular intrahepatic portosystemic shunt was performed. Anemia improved quickly after the transjugular intrahepatic portosystemic shunt, and no further blood transfusion was necessary in the follow-up. The patient developed portal encephalopathy two months later and was readmitted to our department. We repeated the capsule endoscopy that showed a significant improvement of the gastric and ileal mucosa without any signs of bleeding. Conclusion Hypertensive enteropathy is a rare condition, but it seems more common with the introduction of capsule endoscopy in clinical practice. This case shows that the jejunum can be a source of bleeding in cirrhosis patients, and this is the first demonstration of its resolution after transjugular intrahepatic portosystemic shunt placement.

  4. Fifteen-Year-Old Male with Type 2 Autoimmune Pancreatitis: An Argument for Endoscopy

    Directory of Open Access Journals (Sweden)

    Nathan T. Kolasinski

    2017-05-01

    Full Text Available Type 2 autoimmune pancreatitis, an increasingly recognized etiology of pancreatitis in patients less than 20 years old, has characteristically been diagnosed with the histological finding of duct-centric pancreatitis in a patient who lacks elevated serum immunoglobulin G4. We present the case of a nonobese 15-year-old male, without any chronic medical conditions, who presented with the chief complaint of abdominal pain. The laboratory study results were remarkable for a lipase level of 5,419 U/L and a γ-glutamyl transferase level of 373 U/L. Magnetic resonance cholangiopancreatography revealed delayed contrast enhancement of the pancreas, diffuse parenchymal enlargement, and lack of normal lobulation. The patient’s serum immunoglobulin G4 level was found to be 66 mg/dL, which was within normal limits and supportive of a diagnosis of type 2 autoimmune pancreatitis. Despite the absence of intestinal complaints, the patient underwent subsequent endoscopy due to the correlation of type 2 autoimmune pancreatitis with inflammatory bowel disease that has been described in recent literature. Pan-colonic mild colitis was visualized, and the patient began treatment with steroids, to which he quickly responded. Performing endoscopy on this patient allowed for confident initiation of early therapy for both autoimmune pancreatitis and inflammatory bowel disease, and may have limited further surgical intervention and disease progression. For these reasons, this case highlights the utility of endoscopy in pediatric patients with suspected type 2 autoimmune pancreatitis, even in the absence of intestinal symptoms.

  5. Impact of the endoscopist's experience on the negative predictive value of capsule endoscopy.

    Science.gov (United States)

    Velayos Jiménez, Benito; Alcaide Suárez, Noelia; González Redondo, Guillermo; Fernández Salazar, Luis; Aller de la Fuente, Rocío; Del Olmo Martínez, Lourdes; Ruiz Rebollo, Lourdes; González Hernández, José Manuel

    2017-01-01

    The impact of the accumulated experience of the capsule endoscopy (CE) reader on the accuracy of this test is discussed. To determine whether the negative predictive value of CE findings changes along the learning curve. We reviewed the first 900 CE read by 3 gastroenterologists experienced in endoscopy over 8 years. These 900 CE were divided into 3 groups (300 CE each): group 1 consisted of the sum of the first 100 CE read by each of the 3 endoscopists; group 2, the sum of the second 100 and groups 3, the sum of the third 100. Patients with normal CE were monitored for at least 28 months to estimate the negative predictive value. A total of 54 (18%) CE in group 1, 58 (19.3%) in group 2 and 47 (15.6%) in group 3 were normal, although only 34 patients in group 1, 38 in group 2 and 36 in group 3 with normal CE completed follow up and were eventually studied. The negative predictive value was 88.2% in group 1, 89.5% in group 2 and 97% in group 3 (P>.05). The negative predictive value tended to increase, but remained high and did not change significantly after the first 100 when readers are experienced in conventional endoscopy and have preliminary specific training. Copyright © 2016 Elsevier España, S.L.U., AEEH y AEG. All rights reserved.

  6. Head and neck computed tomography virtual endoscopy: evaluation of a new imaging technique.

    Science.gov (United States)

    Gallivan, R P; Nguyen, T H; Armstrong, W B

    1999-10-01

    To evaluate a new radiographic imaging technique: computed tomography virtual endoscopy (CTVE) for head and neck tumors. Twenty-one patients presenting with head and neck masses who underwent axial computed tomography (CT) scan with contrast were evaluated by CTVE. Comparisons were made with video-recorded images and operative records to evaluate the potential utility of this new imaging technique. Twenty-one patients with aerodigestive head and neck tumors were evaluated by CTVE. One patient had a nasal cylindrical cell papilloma; the remainder, squamous cell carcinomas distributed throughout the upper aerodigestive tract. Patients underwent complete head and neck examination, flexible laryngoscopy, axial CT with contrast, CTVE, and in most cases, operative endoscopy. Available clinical and radiographic evaluations were compared and correlated to CTVE findings. CTVE accurately demonstrated abnormalities caused by intraluminal tumor, but where there was apposition of normal tissue against tumor, inaccurate depictions of surface contour occurred. Contour resolution was limited, and mucosal irregularity could not be defined. There was very good overall correlation between virtual images, flexible laryngoscopic findings, rigid endoscopy, and operative evaluation in cases where oncological resections were performed. CTVE appears to be most accurate in evaluation of subglottic and nasopharyngeal anatomy in our series of patients. CTVE is a new radiographic technique that provides surface-contour details. The technique is undergoing rapid technical evolution, and although the image quality is limited in situations where there is apposition of tissue folds, there are a number of potential applications for this new imaging technique.

  7. Endoscopic treatment of chronic pancreatitis: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline

    NARCIS (Netherlands)

    Dumonceau, J.-M.; Delhaye, M.; Tringali, A.; Dominguez-Munoz, J. E.; Poley, J.-W.; Arvanitaki, M.; Costamagna, G.; Costea, F.; Devière, J.; Eisendrath, P.; Lakhtakia, S.; Reddy, N.; Fockens, P.; Ponchon, T.; Bruno, M.

    2012-01-01

    Background and aims: Clarification of the position of the European Society of Gastrointestinal Endoscopy (ESGE) regarding the interventional options available for treating patients with chronic pancreatitis. Methods: Systematic literature search to answer explicit key questions with levels of

  8. Bidirectional effects between parenting and aggressive child behavior in the context of a preventive intervention

    OpenAIRE

    Brinke, L.W. te; Dekovic, M.; Stoltz, S.E.M.J.; Cillessen, A.H.N.

    2017-01-01

    Over time, developmental theories and empirical studies have gradually started to adopt a bidirectional viewpoint. The area of intervention research is, however, lagging behind in this respect. This longitudinal study examined whether bidirectional associations between (changes in) parenting and (changes in) aggressive child behavior over time differed in three conditions: a child intervention condition, a child + parent intervention condition and a control condition. Participants were 267 ch...

  9. Bidirectional Telemetry Controller for Neuroprosthetic Devices

    Science.gov (United States)

    Sharma, Vishnu; McCreery, Douglas B.; Han, Martin; Pikov, Victor

    2010-01-01

    We present versatile multifunctional programmable controller with bidirectional data telemetry, implemented using existing commercial microchips and standard Bluetooth protocol, which adds convenience, reliability, and ease-of-use to neuroprosthetic devices. Controller, weighing 190 g, is placed on animal's back and provides bidirectional sustained telemetry rate of 500 kb/s, allowing real-time control of stimulation parameters and viewing of acquired data. In continuously-active state, controller consumes ∼420 mW and operates without recharge for 8 h. It features independent 16-channel current-controlled stimulation, allowing current steering; customizable stimulus current waveforms; recording of stimulus voltage waveforms and evoked neuronal responses with stimulus artifact blanking circuitry. Flexibility, scalability, cost-efficiency, and a user-friendly computer interface of this device allow use in animal testing for variety of neuroprosthetic applications. Initial testing of the controller has been done in a feline model of brainstem auditory prosthesis. In this model, the electrical stimulation is applied to the array of microelectrodes implanted in the ventral cochlear nucleus, while the evoked neuronal activity was recorded with the electrode implanted in the contralateral inferior colliculus. Stimulus voltage waveforms to monitor the access impedance of the electrodes were acquired at the rate of 312 kilosamples/s. Evoked neuronal activity in the inferior colliculus was recorded after the blanking (transient silencing) of the recording amplifier during the stimulus pulse, allowing the detection of neuronal responses within 100 μs after the end of the stimulus pulse applied in the cochlear nucleus. PMID:19933010

  10. Bidirectional telemetry controller for neuroprosthetic devices.

    Science.gov (United States)

    Sharma, Vishnu; McCreery, Douglas B; Han, Martin; Pikov, Victor

    2010-02-01

    We present versatile multifunctional programmable controller with bidirectional data telemetry, implemented using existing commercial microchips and standard Bluetooth protocol, which adds convenience, reliability, and ease-of-use to neuroprosthetic devices. Controller, weighing 190 g, is placed on animal's back and provides bidirectional sustained telemetry rate of 500 kb/s , allowing real-time control of stimulation parameters and viewing of acquired data. In continuously-active state, controller consumes approximately 420 mW and operates without recharge for 8 h . It features independent 16-channel current-controlled stimulation, allowing current steering; customizable stimulus current waveforms; recording of stimulus voltage waveforms and evoked neuronal responses with stimulus artifact blanking circuitry. Flexibility, scalability, cost-efficiency, and a user-friendly computer interface of this device allow use in animal testing for variety of neuroprosthetic applications. Initial testing of the controller has been done in a feline model of brainstem auditory prosthesis. In this model, the electrical stimulation is applied to the array of microelectrodes implanted in the ventral cochlear nucleus, while the evoked neuronal activity was recorded with the electrode implanted in the contralateral inferior colliculus. Stimulus voltage waveforms to monitor the access impedance of the electrodes were acquired at the rate of 312 kilosamples/s. Evoked neuronal activity in the inferior colliculus was recorded after the blanking (transient silencing) of the recording amplifier during the stimulus pulse, allowing the detection of neuronal responses within 100 mus after the end of the stimulus pulse applied in the cochlear nucleus.

  11. An asymmetric resonant coupling wireless power transmission link for Micro-Ball Endoscopy.

    Science.gov (United States)

    Sun, Tianjia; Xie, Xiang; Li, Guolin; Gu, Yingke; Deng, Yangdong; Wang, Ziqiang; Wang, Zhihua

    2010-01-01

    This paper investigates the design and optimization of a wireless power transmission link targeting Micro-Ball Endoscopy applications. A novel asymmetric resonant coupling structure is proposed to deliver power to an endoscopic Micro-Ball system for image read-out after it is excreted. Such a technology enables many key medical applications with stringent requirements for small system volume and high power delivery efficiency. A prototyping power transmission sub-system of the Micro-Ball system was implemented. It consists of primary coil, middle resonant coil, and cube-like full-direction secondary receiving coils. Our experimental results proved that 200mW of power can be successfully delivered. Such a wireless power transmission capability could satisfy the requirements of the Micro-Ball based endoscopy application. The transmission efficiency is in the range of 41% (worst working condition) to 53% (best working condition). Comparing to conventional structures, Asymmetric Resonant Coupling Structure improves power efficiency by 13%.

  12. Half-unit weighted bilinear algorithm for image contrast enhancement in capsule endoscopy

    Science.gov (United States)

    Rukundo, Olivier

    2018-04-01

    This paper proposes a novel enhancement method based exclusively on the bilinear interpolation algorithm for capsule endoscopy images. The proposed method does not convert the original RBG image components to HSV or any other color space or model; instead, it processes directly RGB components. In each component, a group of four adjacent pixels and half-unit weight in the bilinear weighting function are used to calculate the average pixel value, identical for each pixel in that particular group. After calculations, groups of identical pixels are overlapped successively in horizontal and vertical directions to achieve a preliminary-enhanced image. The final-enhanced image is achieved by halving the sum of the original and preliminary-enhanced image pixels. Quantitative and qualitative experiments were conducted focusing on pairwise comparisons between original and enhanced images. Final-enhanced images have generally the best diagnostic quality and gave more details about the visibility of vessels and structures in capsule endoscopy images.

  13. Virtual endoscopy post-processing of helical CT data sets

    International Nuclear Information System (INIS)

    Dessl, A.; Giacomuzzi, S.M.; Springer, P.; Stoeger, A.; Pototschnig, C.; Voelklein, C.; Schreder, S.G.; Jaschke, W.

    1997-01-01

    Purpose: The purpose of this work was to test a newly developed, post-processing software for virtual CT endoscopic methods. Virtual endoscopic images were generated from helical CT data sets in the region of the shoulder joint (n=2), the tracheobronchial system (n=3), the nasal sinuses (n=2), the colon (n=2), and the common carotid artery (n=1). Software developed specifically for virtual endoscopy ('Navigator') was used which, after a previous threshold value selection, makes the reconstruction of internal body surfaces possible by an automatic segmentation process. We have evaluated the usage of the software, the reconstruction time for individual images and sequences of images as well as the quality of the reconstruction. All pathological findings of the virtual endoscopy were confirmed by surgery. Results: The post-processing program is easy to use and provides virtual endoscopic images within 50 seconds. Depending of the extent of the data set, virtual tracheobronchoscopy as a cine loop sequence required about 15 minutes. Thorugh use of the threshold value-dependent surface reconstruction the demands on the computer configuration are limited; however, this also created quality problems in image calculation as a consequence of the accompanying loss of data. Conclusions: The Navigator software enables the calculation of virtual endoscopic models with only moderate demands on the hardware. (orig.) [de

  14. Bidirectional Prospective Associations between Cardiac Autonomic Activity and Inflammatory Markers

    NARCIS (Netherlands)

    Hu, Mandy X; Lamers, Femke; Neijts, Melanie; Willemsen, Gonneke; de Geus, Eco J C; Penninx, Brenda W J H

    2018-01-01

    OBJECTIVE: Autonomic nervous system (ANS) imbalance has been cross-sectionally associated with inflammatory processes. Longitudinal studies are needed to shed light on the nature of this relationship. We examined cross-sectional and bidirectional prospective associations between cardiac autonomic

  15. Diagnostic Role of Colon Capsule Endoscopy in Patients with Optimal Colon Cleaning

    Directory of Open Access Journals (Sweden)

    Ümit Akyüz

    2016-01-01

    Full Text Available Background. Colon capsule endoscopy (CCE is a diagnostic test with relatively rare usage. In this study, we aimed to evaluate both the optimal cleaning regimen for CCE and the diagnostic value of test in the study group. Methods. A total of 62 patients were enrolled in this study. In the first step, 3 different colon preparing regimens were given to 30 patients [Group A: 3 days of liquid diet, sodium phosphate (NaP (90 mL, and NaP enema; Group B: 3 days of liquid diet, 4 L of polyethylene glycol (PEG, and metoclopramide; Group C: 3 days of liquid diet, 4 L of PEG, NaP (45 mL, and bisacodyl after capsule ingestion] (10 patients in each group. The other consecutive 32 patients were cleaned with the best regimen which was NaP + PEG and CCE was performed. The results of CCE were controlled with colonoscopy in 28 patients. Results. Group C had the highest cleaning score, compared with the other groups (2.2±0.4 versus 2.7±0.4 versus 3.7±0.4, p value =0.000. The CCE findings were as follows in 28 patients who were also examined with colonoscopy: polyp (range: 5–10 mm in 6 patients, internal hemorrhoids in 3 patients, angiodysplasia in 1 patient, diverticula in 1 patient, and ulcerative colitis in 1 patient. The sensitivity, specificity, PPV, and NPV of CCE were 100%, 92%, 93%, and 100%, respectively. Conclusions. Low dosage NaP combined with PEG provides optimal bowel preparation for CCE. CCE appears to be a highly sensitive diagnostic modality for detecting colonic pathologies.

  16. The colon. Clinical radiology and endoscopy

    International Nuclear Information System (INIS)

    Rosenbusch, G.; Reeders, J.W.A.J.

    1993-01-01

    This comprehensive reference work presents in-depth information on the diagnostic radiology and endoscopy of the colon. After a brief review of the history of colon examinations, two chapters explain the anatomy, physiology and pharmacology of the large intestine as well as the methods and techniques applied for radiological examination of the colon. The pathology and characteristical findings and the diagnostic evaluation of the various types of disease are the main subject, with the chapters discussing inflammations and tumors consuming by far most of the space, but there is also valuable information on vascular lesions, traumata, latrogenous or post-surgery lesions, among others, and on the characteristical findings in children. Numerous tables, radiographs and endoscopic images together with drawings illustrate and accompany the textbook information. (orig.). 492 figs., 95 tabs [de

  17. Bidirectional Associations Between Adolescents' Sexual Behaviors and Psychological Well-Being

    NARCIS (Netherlands)

    Nogueira Avelar e Silva, Raquel; van de Bongardt, Daphne; Baams, Laura; Raat, Hein

    Purpose: Assessing bidirectional longitudinal associations between early sexual behaviors (≤16.0 years) and psychological well-being (global self-esteem, physical self-esteem, depression) among 716 adolescents, and the direct and buffering effect of parent-adolescent relationship quality. Methods:

  18. Full spectrum endoscopy (FUSE) versus standard forward-viewing endoscope (SFV) in a high-risk population

    DEFF Research Database (Denmark)

    Roepstorff, Søren; Hadi, Sabah Anwar; Rasmussen, Morten

    2017-01-01

    OBJECTIVES: To investigate the diagnostic performance of Full Spectrum Endoscopy (FUSE) compared to a conventional standard forward-viewing endoscope (SFV). The primary outcome was adenoma detection rate (ADR) and mean adenoma detection. Secondary outcome was feasibility of FUSE opposed to SFV...... intubation time, fentanyl and midazolam sedation, CRC detection, ADR, diverticulosis, bowel preparation, patient discomfort and endoscopist difficulty rating. Participants underwent FUSE colonoscopy on days when the FUSE system was available, while the remaining participants had SFV. All colonoscopies were.......1 ± 6.2 min in the FUSE and SFV groups (p = .040). ADR was 67.0% and 59.6% (p = .097), while the mean adenoma detection was 1.79 and 1.38 (p = .022) in the FUSE and SFV groups. Endoscopists reported increased difficulty rating with FUSE compared to SFV (p > .001). CONCLUSION: FUSE colonoscopy provides...

  19. Streaming video-based 3D reconstruction method compatible with existing monoscopic and stereoscopic endoscopy systems

    Science.gov (United States)

    Bouma, Henri; van der Mark, Wannes; Eendebak, Pieter T.; Landsmeer, Sander H.; van Eekeren, Adam W. M.; ter Haar, Frank B.; Wieringa, F. Pieter; van Basten, Jean-Paul

    2012-06-01

    Compared to open surgery, minimal invasive surgery offers reduced trauma and faster recovery. However, lack of direct view limits space perception. Stereo-endoscopy improves depth perception, but is still restricted to the direct endoscopic field-of-view. We describe a novel technology that reconstructs 3D-panoramas from endoscopic video streams providing a much wider cumulative overview. The method is compatible with any endoscope. We demonstrate that it is possible to generate photorealistic 3D-environments from mono- and stereoscopic endoscopy. The resulting 3D-reconstructions can be directly applied in simulators and e-learning. Extended to real-time processing, the method looks promising for telesurgery or other remote vision-guided tasks.

  20. Significantly reduced hypoxemic events in morbidly obese patients undergoing gastrointestinal endoscopy: Predictors and practice effect

    Directory of Open Access Journals (Sweden)

    Basavana Gouda Goudra

    2014-01-01

    Full Text Available Background: Providing anesthesia for gastrointestinal (GI endoscopy procedures in morbidly obese patients is a challenge for a variety of reasons. The negative impact of obesity on the respiratory system combined with a need to share the upper airway and necessity to preserve the spontaneous ventilation, together add to difficulties. Materials and Methods: This retrospective cohort study included patients with a body mass index (BMI >40 kg/m 2 that underwent out-patient GI endoscopy between September 2010 and February 2011. Patient data was analyzed for procedure, airway management technique as well as hypoxemic and cardiovascular events. Results: A total of 119 patients met the inclusion criteria. Our innovative airway management technique resulted in a lower rate of intraoperative hypoxemic events compared with any published data available. Frequency of desaturation episodes showed statistically significant relation to previous history of obstructive sleep apnea (OSA. These desaturation episodes were found to be statistically independent of increasing BMI of patients. Conclusion: Pre-operative history of OSA irrespective of associated BMI values can be potentially used as a predictor of intra-procedural desaturation. With suitable modification of anesthesia technique, it is possible to reduce the incidence of adverse respiratory events in morbidly obese patients undergoing GI endoscopy procedures, thereby avoiding the need for endotracheal intubation.

  1. Significantly reduced hypoxemic events in morbidly obese patients undergoing gastrointestinal endoscopy: Predictors and practice effect.

    Science.gov (United States)

    Goudra, Basavana Gouda; Singh, Preet Mohinder; Penugonda, Lakshmi C; Speck, Rebecca M; Sinha, Ashish C

    2014-01-01

    Providing anesthesia for gastrointestinal (GI) endoscopy procedures in morbidly obese patients is a challenge for a variety of reasons. The negative impact of obesity on the respiratory system combined with a need to share the upper airway and necessity to preserve the spontaneous ventilation, together add to difficulties. This retrospective cohort study included patients with a body mass index (BMI) >40 kg/m(2) that underwent out-patient GI endoscopy between September 2010 and February 2011. Patient data was analyzed for procedure, airway management technique as well as hypoxemic and cardiovascular events. A total of 119 patients met the inclusion criteria. Our innovative airway management technique resulted in a lower rate of intraoperative hypoxemic events compared with any published data available. Frequency of desaturation episodes showed statistically significant relation to previous history of obstructive sleep apnea (OSA). These desaturation episodes were found to be statistically independent of increasing BMI of patients. Pre-operative history of OSA irrespective of associated BMI values can be potentially used as a predictor of intra-procedural desaturation. With suitable modification of anesthesia technique, it is possible to reduce the incidence of adverse respiratory events in morbidly obese patients undergoing GI endoscopy procedures, thereby avoiding the need for endotracheal intubation.

  2. Effect of music in endoscopy procedures: systematic review and meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Wang, Man Cai; Zhang, Ling Yi; Zhang, Yu Long; Zhang, Ya Wu; Xu, Xiao Dong; Zhang, You Cheng

    2014-10-01

    Endoscopies are common clinical examinations that are somewhat painful and even cause fear and anxiety for patients. We performed this systematic review and meta-analysis of randomized controlled trials to determine the effect of music on patients undergoing various endoscopic procedures. We searched the Cochrane Library, Issue 6, 2013, PubMed, and EMBASE databases up to July 2013. Randomized controlled trials comparing endoscopies, with and without the use of music, were included. Two authors independently abstracted data and assessed risk of bias. Subgroup analyses were performed to examine the impact of music on different types of endoscopic procedures. Twenty-one randomized controlled trials involving 2,134 patients were included. The overall effect of music on patients undergoing a variety of endoscopic procedures significantly improved pain score (weighted mean difference [WMD] = -1.53, 95% confidence interval [CI] [-2.53, -0.53]), anxiety (WMD = -6.04, 95% CI [-9.61, -2.48]), heart rate (P = 0.01), arterial pressure (P music group, compared with the control group. Furthermore, music had little effect for patients undergoing colposcopy and bronchoscopy in the subanalysis. Our meta-analysis suggested that music may offer benefits for patients undergoing endoscopy, except in colposcopy and bronchoscopy. Wiley Periodicals, Inc.

  3. Modified Core Wash Cytology: A reliable same day biopsy result for breast clinics.

    Science.gov (United States)

    Bulte, J P; Wauters, C A P; Duijm, L E M; de Wilt, J H W; Strobbe, L J A

    2016-12-01

    Fine Needle Aspiration Biopsy (FNAB), Core Needle biopsy (CNB) and hybrid techniques including Core Wash Cytology (CWC) are available for same-day diagnosis in breast lesions. In CWC a washing of the biopsy core is processed for a provisional cytological diagnosis, after which the core is processed like a regular CNB. This study focuses on the reliability of CWC in daily practice. All consecutive CWC procedures performed in a referral breast centre between May 2009 and May 2012 were reviewed, correlating CWC results with the CNB result, definitive diagnosis after surgical resection and/or follow-up. Symptomatic as well as screen-detected lesions, undergoing CNB were included. 1253 CWC procedures were performed. Definitive histology showed 849 (68%) malignant and 404 (32%) benign lesions. 80% of CWC procedures yielded a conclusive diagnosis: this percentage was higher amongst malignant lesions and lower for benign lesions: 89% and 62% respectively. Sensitivity and specificity of a conclusive CWC result were respectively 98.3% and 90.4%. The eventual incidence of malignancy in the cytological 'atypical' group (5%) was similar to the cytological 'benign' group (6%). CWC can be used to make a reliable provisional diagnosis of breast lesions within the hour. The high probability of conclusive results in malignant lesions makes CWC well suited for high risk populations. Copyright © 2016 Elsevier Ltd, BASO ~ the Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  4. Bidirectional Dynamic Diversity Evolutionary Algorithm for Constrained Optimization

    Directory of Open Access Journals (Sweden)

    Weishang Gao

    2013-01-01

    Full Text Available Evolutionary algorithms (EAs were shown to be effective for complex constrained optimization problems. However, inflexible exploration-exploitation and improper penalty in EAs with penalty function would lead to losing the global optimum nearby or on the constrained boundary. To determine an appropriate penalty coefficient is also difficult in most studies. In this paper, we propose a bidirectional dynamic diversity evolutionary algorithm (Bi-DDEA with multiagents guiding exploration-exploitation through local extrema to the global optimum in suitable steps. In Bi-DDEA potential advantage is detected by three kinds of agents. The scale and the density of agents will change dynamically according to the emerging of potential optimal area, which play an important role of flexible exploration-exploitation. Meanwhile, a novel double optimum estimation strategy with objective fitness and penalty fitness is suggested to compute, respectively, the dominance trend of agents in feasible region and forbidden region. This bidirectional evolving with multiagents can not only effectively avoid the problem of determining penalty coefficient but also quickly converge to the global optimum nearby or on the constrained boundary. By examining the rapidity and veracity of Bi-DDEA across benchmark functions, the proposed method is shown to be effective.

  5. Role of enhanced multi-detector-row computed tomography before urgent endoscopy in acute upper gastrointestinal bleeding.

    Science.gov (United States)

    Miyaoka, Youichi; Amano, Yuji; Ueno, Sayaka; Izumi, Daisuke; Mikami, Hironobu; Yazaki, Tomotaka; Okimoto, Eiko; Sonoyama, Takayuki; Ito, Satoko; Fujishiro, Hirofumi; Kohge, Naruaki; Imaoka, Tomonori

    2014-04-01

    Multi-detector-row computed tomography (MDCT) has been reported to be a potentially useful modality for detection of the bleeding origin in patients with acute upper massive gastrointestinal (GI) bleeding. The purpose of this study is to investigate the efficacy of MDCT as a routine method for detecting the origin of acute upper GI bleeding prior to urgent endoscopy. Five hundred seventy-seven patients with acute upper GI bleeding (514 nonvariceal patients, 63 variceal patients) who underwent urgent upper GI endoscopy were retrospectively analyzed. Patients were divided into three groups: enhanced MDCT, unenhanced MDCT, and no MDCT before endoscopy. The diagnostic accuracy of MDCT for detection of the bleeding origin was evaluated, and the average procedure times needed to endoscopically identify the bleeding origin were compared between groups. Diagnostic accuracy among endoscopists was 55.3% and 14.7% for the enhanced MDCT and unenhanced MDCT groups, respectively. Among nonvariceal patients, accuracy was 50.2% in the enhanced MDCT group, which was significantly better than that in the unenhanced MDCT group (16.5%). In variceal patients, accuracy was significantly better in the enhanced MDCT group (96.4%) than in the unenhanced MDCT group (0.0%). These accuracies were similar to those achieved by expert radiologists. The average procedure time to endoscopic detection of the bleeding origin in the enhanced MDCT group was significantly faster than that in the unenhanced MDCT and no-MDCT groups. Enhanced MDCT preceding urgent endoscopy may be an effective modality for the detection of bleeding origin in patients with acute upper GI bleeding. © 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  6. Mechanical and abrasive wear characterization of bidirectional and chopped E-glass fiber reinforced composite materials

    International Nuclear Information System (INIS)

    Siddhartha,; Gupta, Kuldeep

    2012-01-01

    Highlights: ► Bi-directional and chopped E-glass fiber reinforced epoxy composites are fabricated. ► Three body abrasive wear behavior of fabricated composites has been assessed. ► Results are validated against existing microscopic models of Lancaster and Wang. ► Tensile strength of bi-directional E-glass fiber reinforced composites increases. ► Chopped glass fiber composites are found better in abrasive wear situations. -- Abstract: Bi-directional and chopped E-glass fiber reinforced epoxy composites are fabricated in five different (15, 20, 25, 30 and 35) wt% in an epoxy resin matrix. The mechanical characterization of these composites is performed. The three body abrasive wear behavior of fabricated composites has been assessed under different operating conditions. Abrasive wear characteristics of these composites are successfully analysed using Taguchi’s experimental design scheme and analysis of variance (ANOVA). The results obtained from these experiments are also validated against existing microscopic models of Ratner-Lancaster and Wang. It is observed that quite good linear relationships is held between specific wear rate and reciprocal of ultimate strength and strain at tensile fracture of these composites which is an indicative that the experimental results are in fair agreement with these existing models. Out of all composites fabricated it is found that tensile strength of bi-directional E-glass fiber reinforced composites increases because of interface strength enhancement. Chopped glass fiber reinforced composites are observed to perform better than bi-directional glass fiber reinforced composites under abrasive wear situations. The morphology of worn composite specimens has been examined by scanning electron microscopy (SEM) to understand about dominant wear mechanisms.

  7. Bidirectional Associations Between Externalizing Behavior Problems and Maladaptive Parenting Within Parent-Son Dyads Across Childhood.

    Science.gov (United States)

    Besemer, Sytske; Loeber, Rolf; Hinshaw, Stephen P; Pardini, Dustin A

    2016-10-01

    Coercive parent-child interaction models posit that an escalating cycle of negative, bidirectional interchanges influences the development of boys' externalizing problems and caregivers' maladaptive parenting over time. However, longitudinal studies examining this hypothesis have been unable to rule out the possibility that between-individual factors account for bidirectional associations between child externalizing problems and maladaptive parenting. Using a longitudinal sample of boys (N = 503) repeatedly assessed eight times across 6-month intervals in childhood (in a range between 6 and 13 years), the current study is the first to use novel within-individual change (fixed effects) models to examine whether parents tend to increase their use of maladaptive parenting strategies following an increase in their son's externalizing problems, or vice versa. These bidirectional associations were examined using multiple facets of externalizing problems (i.e., interpersonal callousness, conduct and oppositional defiant problems, hyperactivity/impulsivity) and parenting behaviors (i.e., physical punishment, involvement, parent-child communication). Analyses failed to support the notion that when boys increase their typical level of problem behaviors, their parents show an increase in their typical level of maladaptive parenting across the subsequent 6 month period, and vice versa. Instead, across 6-month intervals, within parent-son dyads, changes in maladaptive parenting and child externalizing problems waxed and waned in concert. Fixed effects models to address the topic of bidirectional relations between parent and child behavior are severely underrepresented. We recommend that other researchers who have found significant bidirectional parent-child associations using rank-order change models reexamine their data to determine whether these findings hold when examining changes within parent-child dyads.

  8. Reward-timing-dependent bidirectional modulation of cortical microcircuits during optical single-neuron operant conditioning.

    Science.gov (United States)

    Hira, Riichiro; Ohkubo, Fuki; Masamizu, Yoshito; Ohkura, Masamichi; Nakai, Junichi; Okada, Takashi; Matsuzaki, Masanori

    2014-11-24

    Animals rapidly adapt to environmental change. To reveal how cortical microcircuits are rapidly reorganized when an animal recognizes novel reward contingency, we conduct two-photon calcium imaging of layer 2/3 motor cortex neurons in mice and simultaneously reinforce the activity of a single cortical neuron with water delivery. Here we show that when the target neuron is not relevant to a pre-trained forelimb movement, the mouse increases the target neuron activity and the number of rewards delivered during 15-min operant conditioning without changing forelimb movement behaviour. The reinforcement bidirectionally modulates the activity of subsets of non-target neurons, independent of distance from the target neuron. The bidirectional modulation depends on the relative timing between the reward delivery and the neuronal activity, and is recreated by pairing reward delivery and photoactivation of a subset of neurons. Reward-timing-dependent bidirectional modulation may be one of the fundamental processes in microcircuit reorganization for rapid adaptation.

  9. Bidirectional automatic release of reserve for low voltage network made with low capacity PLCs

    Science.gov (United States)

    Popa, I.; Popa, G. N.; Diniş, C. M.; Deaconu, S. I.

    2018-01-01

    The article presents the design of a bidirectional automatic release of reserve made on two types low capacity programmable logic controllers: PS-3 from Klöckner-Moeller and Zelio from Schneider. It analyses the electronic timing circuits that can be used for making the bidirectional automatic release of reserve: time-on delay circuit and time-off delay circuit (two types). In the paper are present the sequences code for timing performed on the PS-3 PLC, the logical functions for the bidirectional automatic release of reserve, the classical control electrical diagram (with contacts, relays, and time relays), the electronic control diagram (with logical gates and timing circuits), the code (in IL language) made for the PS-3 PLC, and the code (in FBD language) made for Zelio PLC. A comparative analysis will be carried out on the use of the two types of PLC and will be present the advantages of using PLCs.

  10. Studi Komparasi Fungsi Keanggotaan Fuzzy sebagai Kontroler Bidirectional DC-DC Converter pada Sistem Penyimpan Energi

    Directory of Open Access Journals (Sweden)

    Eka Prasetyono

    2015-09-01

    Full Text Available Bidirectional DC-DC converter is needed in the energy storage system. The converter topology used in this paper was a non-isolated bidirectional DC-DC buck-boost converter. This converter worked in two ways, which the charging mode stored energy into battery when load current was less than nominal main DC current (set point and discharging mode transferred energy from battery to the load when its current exceeded set point value. Both of these modes worked automatically according to the load current. The charging and discharging currents were controlled by fuzzy logic controller which was implemented on microcontroller ARM Cortex-M4F STM32F407VG. This paper compares two types of fuzzy membership function (triangular and sigmoid in controlling bidirectional DC-DC converter. The results showed that fuzzy logic controller with triangle membership function and sigmoid as control bidirectional DC-DC converter had no significant different response, both had an average error for charging and discharging process under 4% with ripple current on the main DC bus around 0.5%. The computing time of program for fuzzy logic controller with triangular membership functions had 19.01% faster than sigmoid, and fuzzy logic computation time on a microcontroller with hardware floating point was 60% faster than software floating point.

  11. Prevalence of small-bowel neoplasia in Lynch syndrome assessed by video capsule endoscopy

    NARCIS (Netherlands)

    Haanstra, Jasmijn F.; Al-Toma, Abdul; Dekker, Evelien; Vanhoutvin, Steven A. L. W.; Nagengast, Fokko M.; Mathus-Vliegen, Elisabeth M.; van Leerdam, Monique E.; Cappel, Wouter H. de Vos tot Nederveen; Sanduleanu, Silvia; Veenendaal, Roeland A.; Cats, Annemieke; Vasen, Hans F. A.; Kleibeuker, Jan H.; Koornstra, Jan J.

    2015-01-01

    Objective The aim was to determine the prevalence of small-bowel neoplasia in asymptomatic patients with Lynch syndrome (LS) by video capsule endoscopy (VCE). Design After obtaining informed consent, asymptomatic proven gene mutation carriers aged 3570 years were included in this prospective

  12. Small bowel involvement documented by capsule endoscopy in Churg-Strauss syndrome.

    Science.gov (United States)

    Beye, Birane; Lesur, Gilles; Claude, Pierre; Martzolf, Lionel; Kieffer, Pierre; Sondag, Daniel

    2015-01-01

    Churg-Strauss syndrome is a small and medium vessel vasculitis and is also known as allergic granulomatous angiitis. Gastrointestinal involvement is common in patients with Churg-Strauss syndrome (20-50%). The most common symptoms are abdominal pain, diarrhoea and occasionally gastrointestinal bleeding and perforation. We present a case of Churg-Strauss syndrome with small bowel lesions documented by video capsule endoscopy.

  13. Control of parallel-connected bidirectional AC-DC converters in stationary frame for microgrid application

    DEFF Research Database (Denmark)

    Lu, Xiaonan; Guerrero, Josep M.; Teodorescu, Remus

    2011-01-01

    With the penetration of renewable energy in modern power system, microgrid has become a popular application worldwide. In this paper, parallel-connected bidirectional converters for AC and DC hybrid microgrid application are proposed as an efficient interface. To reach the goal of bidirectional...... power conversion, both rectifier and inverter modes are analyzed. In order to achieve high performance operation, hierarchical control system is accomplished. The control system is designed in stationary frame, with harmonic compensation in parallel and no coupled terms between axes. In this control...

  14. Current status of core and advanced adult gastrointestinal endoscopy training in Canada: Survey of existing accredited programs.

    Science.gov (United States)

    Xiong, Xin; Barkun, Alan N; Waschke, Kevin; Martel, Myriam

    2013-01-01

    To determine the current status of core and advanced adult gastroenterology training in Canada. A survey consisting of 20 questions pertaining to core and advanced endoscopy training was circulated to 14 accredited adult gastroenterology residency program directors. For continuous variables, median and range were analyzed; for categorical variables, percentage and associated 95% CIs were analyzed. All 14 programs responded to the survey. The median number of core trainees was six (range four to 16). The median (range) procedural volumes for gastroscopy, colonoscopy, percutaneous endoscopic gastrostomy and sigmoidoscopy, respectively, were 400 (150 to 1000), 325 (200 to 1500), 15 (zero to 250) and 60 (25 to 300). Eleven of 13 (84.6%) programs used endoscopy simulators in their curriculum. Eight of 14 programs (57%) provided a structured advanced endoscopy training fellowship. The majority (88%) offered training of combined endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic ultrasonography. The median number of positions offered yearly for advanced endoscopy fellowship was one (range one to three). The median (range) procedural volumes for ERCP, endoscopic ultrasonography and endoscopic mucosal resection, respectively, were 325 (200 to 750), 250 (80 to 400) and 20 (10 to 63). None of the current programs offered training in endoscopic submucosal dissection or natural orifice transluminal endoscopic surgery. Most accredited adult Canadian gastroenterology programs met the minimal procedural requirements recommended by the Canadian Association of Gastroenterology during core training. However, a more heterogeneous experience has been observed for advanced training. Additional studies would be required to validate and standardize evaluation tools used during gastroenterology curricula.

  15. Prevalence of small-bowel neoplasia in Lynch syndrome assessed by video capsule endoscopy

    NARCIS (Netherlands)

    Haanstra, Jasmijn F.; Al-Toma, Abdul; Dekker, Evelien; Vanhoutvin, Steven A. L. W.; Nagengast, Fokko M.; Mathus-Vliegen, Elisabeth M.; van Leerdam, Monique E.; de Vos tot Nederveen Cappel, Wouter H.; Sanduleanu, Silvia; Veenendaal, Roeland A.; Cats, Annemieke; Vasen, Hans F. A.; Kleibeuker, Jan H.; Koornstra, Jan J.

    2015-01-01

    The aim was to determine the prevalence of small-bowel neoplasia in asymptomatic patients with Lynch syndrome (LS) by video capsule endoscopy (VCE). After obtaining informed consent, asymptomatic proven gene mutation carriers aged 35-70 years were included in this prospective multicentre study in

  16. Surveillance of FAP: a prospective blinded comparison of capsule endoscopy and other GI imaging to detect small bowel polyps

    Directory of Open Access Journals (Sweden)

    Tescher Paul

    2010-04-01

    Full Text Available Abstract Background Familial adenomatous polyposis (FAP is a hereditary disorder characterized by polyposis along the gastrointestinal tract. Information on adenoma status below the duodenum has previously been restricted due to its inaccessibility in vivo. Capsule Endoscopy (CE may provide a useful adjunct in screening for polyposis in the small bowel in FAP patients. This study aims to evaluate the effectiveness of CE in the assessment of patients with FAP, compared to other imaging modalities for the detection of small bowel polyps. Method 20 consecutive patients with previously diagnosed FAP and duodenal polyps, presenting for routine surveillance of polyps at The Royal Melbourne Hospital were recruited. Each fasted patient initially underwent a magnetic resonance image (MRI of the abdomen, and a barium small bowel follow-through study. Capsule Endoscopy was performed four weeks later on the fasted patient. An upper gastrointestinal side-viewing endoscopy was done one (1 to two (2 weeks after this. Endoscopists and investigators were blinded to results of other investigations and patient history. Results Within the stomach, upper gastrointestinal endoscopy found more polyps than other forms of imaging. SBFT and MRI generally performed poorly, identifying fewer polyps than both upper gastrointestinal and capsule endoscopy. CE was the only form of imaging that identified polyps in all segments of the small bowel as well as the only form of imaging able to provide multiple findings outside the stomach/duodenum. Conclusion CE provides important information on possible polyp development distal to the duodenum, which may lead to surgical intervention. The place of CE as an adjunct in surveillance of FAP for a specific subset needs consideration and confirmation in replication studies. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN12608000616370

  17. Colours sometimes count : Awareness and bidirectionality in grapheme-colour synaesthesia

    NARCIS (Netherlands)

    Johnson, Addie; Jepma, Marieke; de Jong, Ritske

    2007-01-01

    Three experiments were conducted with 10 grapheme-colour synaesthetes and 10 matched controls to investigate (a) whether awareness of the inducer grapheme is necessary for synaesthetic colour induction and (b) whether grapheme-colour synaesthesia may be bidirectional in the sense that not only do

  18. Bidirectional electrostatic linear shuffle motor with two degrees of freedom

    NARCIS (Netherlands)

    Sarajlic, Edin; Berenschot, Johan W.; Fujita, H.; Krijnen, Gijsbertus J.M.; Elwenspoek, Michael Curt

    2005-01-01

    We report on an electrostatic linear inchworm micromotor with two translational degrees-of-freedom. The motor employs built-in mechanical leverage to convert normal deflection of a flexible cross-plate into a small in-plane step and four electrostatic clamps to enable bidirectional inchworm motion

  19. Frequency of peptic ulcer disease in patients of dyspepsia an analysis of upper gastrointestinal endoscopy

    International Nuclear Information System (INIS)

    Anwar, S.O.; Ambreen, S.; Ashraf, H.M.

    2010-01-01

    To evaluate the frequency of peptic ulcer disease in patients of dyspepsia on upper gastrointestinal endoscopy. A convenient non probability sampling was done and one hundred patients were selected from out patient department presenting within six months of dyspeptic symptoms. They were all subjected to upper gastrointestinal endoscopy Of all patients 61% (n=61) were males and 39% (n=39) were females with age ranging between 20 - 45 years. Study revealed functional dyspepsia (76%), duodenal ulcer (11%), gastric ulcer (4%) and esophagitis including gastoesophageal reflux disease (9%). This showed an overall frequency of peptic ulcer disease to be 15% in the studied population.Conclusion: Peptic ulcer disease is a common structural cause of dyspepsia and was responsible for 15% of dyspepsia. (author)

  20. Magnetically actuated bi-directional microactuators with permalloy and Fe/Pt hard magnet

    International Nuclear Information System (INIS)

    Pan, C.T.; Shen, S.C.

    2005-01-01

    Bi-directional polyimide (PI) electromagnetic microactuator with different geometries are designed, fabricated and tested. Fabrication of the electromagnetic microactuator consists of 10 μm thick Ni/Fe (80/20) permalloy deposition on the PI diaphragm by electroplating, high aspect ratio electroplating of copper planar coil with 10 μm in thickness, bulk micromachining, and excimer laser selective ablation. They were fabricated by a novel concept avoiding the etching selectivity and residual stress problems during wafer etching. A mathematical model is created by ANSYS software to analyze the microactuator. The external magnetic field intensity (H ext ) generated by the planar coil is simulated by ANSYS software. ANSYS software is used to predict the deflection angle of the microactuator. Besides, to provide bi-directional and large deflection angle of microactuator, hard magnet Fe/Pt is deposited at a low temperature of 300 deg. C by sputtering onto the PI diaphragm to produce a perpendicular magnetic anisotropic field. This magnetic field can enhance the interaction with H ext to induce attractive and repulsive bi-directional force to provide large displacement. The results of magnetic microactuator with and without hard magnets are compared and discussed. The preliminary result reveals that the electromagnetic microactuator with hard magnet shows a greater deflection angle than that without one

  1. Common Arterial Trunk in a 3-Day-Old Alpaca Cria

    Directory of Open Access Journals (Sweden)

    Tsumugi Anne Kurosawa

    2016-01-01

    Full Text Available A 3-day-old alpaca cria presented for progressive weakness and dyspnea since birth. Complete bloodwork, thoracic radiographs, and endoscopic examination of the nasal passages and distal trachea revealed no significant findings. Echocardiogram and contrast study revealed a single artery overriding a large ventricular septal defect (VSD. A small atrial septal defect or patent foramen ovale was also noted. Color flow Doppler and an agitated saline contrast study revealed bidirectional but primarily right to left flow through the VSD and bidirectional shunting through the atrial defect. Differential diagnosis based on echocardiographic findings included common arterial trunk, Tetralogy of Fallot, and pulmonary atresia with a VSD. Postmortem examination revealed a large common arterial trunk with a quadricuspid valve overriding a VSD. Additionally, defect in the atrial septum was determined to be a patent foramen ovale. A single pulmonary trunk arose from the common arterial trunk and bifurcated to the left and right pulmonary artery, consistent with a Collet and Edwards’ type I common arterial trunk with aortic predominance. Although uncommon, congenital cardiac defects should be considered in animals presenting with clinical signs of hypoxemia, dyspnea, or failure to thrive.

  2. Calculus detection calibration among dental hygiene faculty members utilizing dental endoscopy: a pilot study.

    Science.gov (United States)

    Partido, Brian B; Jones, Archie A; English, Dana L; Nguyen, Carol A; Jacks, Mary E

    2015-02-01

    Dental and dental hygiene faculty members often do not provide consistent instruction in the clinical environment, especially in tasks requiring clinical judgment. From previous efforts to calibrate faculty members in calculus detection using typodonts, researchers have suggested using human subjects and emerging technology to improve consistency in clinical instruction. The purpose of this pilot study was to determine if a dental endoscopy-assisted training program would improve intra- and interrater reliability of dental hygiene faculty members in calculus detection. Training included an ODU 11/12 explorer, typodonts, and dental endoscopy. A convenience sample of six participants was recruited from the dental hygiene faculty at a California community college, and a two-group randomized experimental design was utilized. Intra- and interrater reliability was measured before and after calibration training. Pretest and posttest Kappa averages of all participants were compared using repeated measures (split-plot) ANOVA to determine the effectiveness of the calibration training on intra- and interrater reliability. The results showed that both kinds of reliability significantly improved for all participants and the training group improved significantly in interrater reliability from pretest to posttest. Calibration training was beneficial to these dental hygiene faculty members, especially those beginning with less than full agreement. This study suggests that calculus detection calibration training utilizing dental endoscopy can effectively improve interrater reliability of dental and dental hygiene clinical educators. Future studies should include human subjects, involve more participants at multiple locations, and determine whether improved rater reliability can be sustained over time.

  3. Capsule Endoscopy in the Investigation of Patients with Portal Hypertension and Anemia

    Directory of Open Access Journals (Sweden)

    Spyros Goulas

    2008-01-01

    Full Text Available INTRODUCTION: Data on small bowel abnormalities in patients with portal hypertension (PHT are limited. Bleeding from the gastrointestinal tract and anemia are common complications in these patients. Capsule endoscopy (CE was used to evaluate small bowel (SB pathology in patients with PHT and anemia, and possible associations with various parameters were examined.

  4. Interplanetary magnetic field orientations associated with bidirectional electron heat fluxes detected at ISEE 3

    International Nuclear Information System (INIS)

    Stansberry, J.A.; Gosling, J.T.; Thomsen, M.F.; Bame, S.J.; Smith, E.J.

    1988-01-01

    A statistical survey of interplanetary magnetic field orientations associated with bidirectional electron heat fluxes observed at ISEE 3 in orbit about the Sunward Lagrange point indicates that magnetic connection of the spacecraft to the Earth's bow shock was frequently the source of the bidirectionality. When the interplanetary magnetic field was oriented within 5 0 of the Earth-spacecraft line, backstreaming electrons from the bow shock were clearly observed approximately 18% of the time, and connections apparently occurred for angles as large as ∼30 0 --35 0 . copyright American Geophysical Union 1988

  5. Sex differences in dreaming during short propofol sedation for upper gastrointestinal endoscopy.

    Science.gov (United States)

    Xu, Guanghong; Liu, Xuesheng; Sheng, Qiying; Yu, Fengqiong; Wang, Kai

    2013-10-02

    Previous reports suggest that sex differences may exist in dreaming under anesthesia, but their results were inconclusive. The current study explored sex differences in the incidence and content of dreams during short propofol sedation for upper gastrointestinal endoscopy and investigated whether sex differences or dream content affect patient satisfaction with sedation. A total of 200 patients (100 men and 100 women) undergoing upper gastrointestinal endoscopy participated in this study. Patients were interviewed with the modified Brice questionnaire about the incidence and the content of dreams, and satisfaction with sedation was assessed. The results showed that the incidence of dreaming was significantly higher in men (31%) than in women (17%) (P=0.02), but recovery time was similar. In men, 45% (14/31) of dreamers reported positive emotional content and only 6% (2/31) reported negative emotional content. In contrast, in women, 18% (3/17) reported positive and 29% (5/17) reported negative content (P=0.04). Men reported dreams that were more vivid, meaningful, familiar, and memorable (PDreamer satisfaction with sedation was not influenced by sex or dream content.

  6. Intracorneal ring segments implantation followed by same-day topography-guided PRK and corneal collagen CXL in low to moderate keratoconus.

    Science.gov (United States)

    Al-Tuwairqi, Waleed; Sinjab, Mazen M

    2013-01-01

    To evaluate the safety and efficacy of intrastromal corneal ring segments (ICRS) implantation followed by same-day topography-guided photorefractive keratectomy (PRK) and ultraviolet-A/riboflavin collagen cross-linking (CXL) in patients with low to moderate keratoconus. Patients with low to moderate keratoconus and contact lens intolerance were included in the study. All patients first underwent femtosecond laser-enabled placement of ICRS (Keraring, Mediphacos) (first step). Same-day topography-guided PRK and CXL (second step) were subsequently performed in all patients after the refraction was stable (average 6 months [range: 3 to 11 months]). Thirteen eyes from 13 patients were included in the study. Based on values before the first step and 6 months after the second step, significant improvements were noted in uncorrected distance visual acuity (0.7±0.32 logMAR vs 0.08±0.08 logMAR), corrected distance visual acuity (CDVA) (0.16±0.19 logMAR vs 0.02±0.04 log-MAR), sphere (-3.65±3.08 diopters [D] vs 0.06±1.6 D), astigmatism (-3.31±1.5 D vs -0.98±0.75 D), average K (47.28±1.99 D vs 41.42±3.22 D), and coma (2.36±1.23 μm vs 1.47±0.68 μm) (PPRK/CXL may be a reasonable option for improving visual acuity in patients with low to moderate keratoconus. Copyright 2013, SLACK Incorporated.

  7. Computer-aided detection of early cancer in the esophagus using HD endoscopy images

    NARCIS (Netherlands)

    Sommen, van der F.; Zinger, S.; Schoon, E.J.; With, de P.H.N.

    2013-01-01

    Esophageal cancer is the fastest rising type of cancer in the Western world. The recent development of High-Definition (HD) endoscopy has enabled the specialist physician to identify cancer at an early stage. Nevertheless, it still requires considerable effort and training to be able to recognize

  8. Bidirectional Hebbian Plasticity Induced by Low-Frequency Stimulation in Basal Dendrites of Rat Barrel Cortex Layer 5 Pyramidal Neurons.

    Science.gov (United States)

    Díez-García, Andrea; Barros-Zulaica, Natali; Núñez, Ángel; Buño, Washington; Fernández de Sevilla, David

    2017-01-01

    According to Hebb's original hypothesis (Hebb, 1949), synapses are reinforced when presynaptic activity triggers postsynaptic firing, resulting in long-term potentiation (LTP) of synaptic efficacy. Long-term depression (LTD) is a use-dependent decrease in synaptic strength that is thought to be due to synaptic input causing a weak postsynaptic effect. Although the mechanisms that mediate long-term synaptic plasticity have been investigated for at least three decades not all question have as yet been answered. Therefore, we aimed at determining the mechanisms that generate LTP or LTD with the simplest possible protocol. Low-frequency stimulation of basal dendrite inputs in Layer 5 pyramidal neurons of the rat barrel cortex induces LTP. This stimulation triggered an EPSP, an action potential (AP) burst, and a Ca 2+ spike. The same stimulation induced LTD following manipulations that reduced the Ca 2+ spike and Ca 2+ signal or the AP burst. Low-frequency whisker deflections induced similar bidirectional plasticity of action potential evoked responses in anesthetized rats. These results suggest that both in vitro and in vivo similar mechanisms regulate the balance between LTP and LTD. This simple induction form of bidirectional hebbian plasticity could be present in the natural conditions to regulate the detection, flow, and storage of sensorimotor information.

  9. Bidirectional Hebbian Plasticity Induced by Low-Frequency Stimulation in Basal Dendrites of Rat Barrel Cortex Layer 5 Pyramidal Neurons

    Science.gov (United States)

    Díez-García, Andrea; Barros-Zulaica, Natali; Núñez, Ángel; Buño, Washington; Fernández de Sevilla, David

    2017-01-01

    According to Hebb's original hypothesis (Hebb, 1949), synapses are reinforced when presynaptic activity triggers postsynaptic firing, resulting in long-term potentiation (LTP) of synaptic efficacy. Long-term depression (LTD) is a use-dependent decrease in synaptic strength that is thought to be due to synaptic input causing a weak postsynaptic effect. Although the mechanisms that mediate long-term synaptic plasticity have been investigated for at least three decades not all question have as yet been answered. Therefore, we aimed at determining the mechanisms that generate LTP or LTD with the simplest possible protocol. Low-frequency stimulation of basal dendrite inputs in Layer 5 pyramidal neurons of the rat barrel cortex induces LTP. This stimulation triggered an EPSP, an action potential (AP) burst, and a Ca2+ spike. The same stimulation induced LTD following manipulations that reduced the Ca2+ spike and Ca2+ signal or the AP burst. Low-frequency whisker deflections induced similar bidirectional plasticity of action potential evoked responses in anesthetized rats. These results suggest that both in vitro and in vivo similar mechanisms regulate the balance between LTP and LTD. This simple induction form of bidirectional hebbian plasticity could be present in the natural conditions to regulate the detection, flow, and storage of sensorimotor information. PMID:28203145

  10. Bidirectional Relations between Authoritative Parenting and Adolescents' Prosocial Behaviors

    Science.gov (United States)

    Padilla-Walker, Laura M.; Carlo, Gustavo; Christensen, Katherine J.; Yorgason, Jeremy B.

    2012-01-01

    This study examined the bidirectional relations between authoritative parenting and adolescents' prosocial behavior over a 1-year time period. Data were taken from Time 2 and 3 of the Flourishing Families Project, and included reports from 319 two-parent families with an adolescent child (M age of child at Time 2 = 12.34, SD = 1.06, 52% girls).…

  11. Prevalence and predictors of columnar lined esophagus in gastroesophageal reflux disease (GERD) patients undergoing upper endoscopy.

    Science.gov (United States)

    Balasubramanian, Gokulakrishnan; Singh, Mandeep; Gupta, Neil; Gaddam, Srinivas; Giacchino, Maria; Wani, Sachin B; Moloney, Brian; Higbee, April D; Rastogi, Amit; Bansal, Ajay; Sharma, Prateek

    2012-11-01

    Chronic gastroesophageal reflux disease (GERD) is a risk factor for Barrett's esophagus (BE), the most important surrogate marker for the development of esophageal adenocarcinoma (EAC). The need to document the presence of intestinal metaplasia in esophageal biopsies from a columnar lined esophagus (CLE) to diagnose BE is debated. The objective of this study was to prospectively evaluate the prevalence and risk factors of CLE in a large cohort of GERD patients undergoing upper endoscopy. Consecutive patients presenting to the endoscopy unit at a tertiary referral center for their index upper endoscopy for evaluation of GERD symptoms were enrolled in this prospective cohort study. Patients were asked to complete a validated GERD questionnaire that documents the onset of GERD symptoms (heartburn and acid regurgitation) and grades the frequency and severity of symptoms experienced over the past year. Demographic information, body mass index, and use of aspirin/nonsteroidal antiinflammatory drugs were recorded. Endoscopic details including length of CLE, presence and size of hiatal hernia were noted. Patients with CLE (cases) were compared with those without CLE (controls) using Fischer's exact test and t-test. All factors that were statistically significant (PGERD symptoms were prospectively enrolled. On index endoscopy, the prevalence of CLE was 23.3%, whereas of CLE with documented intestinal metaplasia was 14.1%. On univariate analysis, male gender, Caucasian race, heartburn duration of >5 years, presence and size of hiatal hernia were significantly associated with the presence of CLE compared with controls (P5 years (odds ratio (OR): 1.50, 95% confidence interval (CI): 1.07-2.09, P=0.01), Caucasian race (OR: 2.40, 95% CI: 1.42-4.03, P=0.001), and hiatal hernia (OR: 2.07, 95% CI: 1.50-2.87, PGERD patients are diagnosed with this lesion. Enrolling all these patients in surveillance programs would have significant ramifications on health-care resources.

  12. Simulation-based patient flow analysis in an endoscopy unit

    DEFF Research Database (Denmark)

    Koo, Pyung-Hoi; Nielsen, Karl Brian; Jang, Jaejin

    2010-01-01

    One of the major elements in improving efficiency of healthcare services is patient flow. Patients require a variety of healthcare resources as they receive healthcare services. Poor management of patient flow results in long waiting time of patients, under/over utilization of medical resources......, low quality of care and high healthcare cost. This article addresses patient flow problems at a Gastrointestinal endoscopy unit. We attempt to analyze the main factors that contribute to the inefficient patient flow and process bottlenecks and to propose efficient patient scheduling and staff...

  13. Complementary roles of interventional radiology and therapeutic endoscopy in gastroenterology

    DEFF Research Database (Denmark)

    Ray, David M; Srinivasan, Indu; Tang, Shou-Jiang

    2017-01-01

    radiology have resulted in the paradigm shift in the management of these conditions. In this paper, we discuss the patient's work up, indications, and complementary roles of endoscopic and angiographic management in the settings of gastrointestinal bleeding, enteral feeding, cecostomy tube placement...... and luminal strictures. These conditions often require multidisciplinary approaches involving a team of interventional radiologists, gastroenterologists and surgeons. Further, the authors also aim to describe how the fields of interventional radiology and gastrointestinal endoscopy are overlapping...

  14. Visual rehabilitation in low-moderate keratoconus:intracorneal ring segment implantation followed by same-day topography-guided photorefractive keratectomy and collagen cross linking

    Directory of Open Access Journals (Sweden)

    Ferial M. Zeraid

    2014-10-01

    Full Text Available AIM:To present the results of same-day topography-guided photorefractive keratectomy (TG-PRK and corneal collagen crosslinking (CXL after previous intrastromal corneal ring segment (ISCR implantation for keratoconus.METHODS:An experimental clinical study on twenty-one eyes of 19 patients aged 27.1±6.6y (range 19-43y, with low to moderate keratoconus who were selected to undergo customized TG-PRK immediately followed by same-day CXL, 9mo after ISCR implantation in a university ophthalmology clinic. Refraction, uncorrected distance visual acuities (UDVA and corrected distance visual acuities (CDVA, keratometry (K values, central corneal thickness (CCT and coma were assessed 3mo after TG-PRK and CXL.RESULTS:After TG-PRK/CXL:the mean UDVA (logMAR improved significantly from 0.66±0.41 to 0.20±0.25 (P<0.05; Kflat value decreased from:48.44±3.66 D to 43.71±1.95 D; Ksteep value decreased from 45.61±2.40 D to 41.56±2.05 D; Kaverage also decreased from 47.00±2.66 D to 42.42±2.07 D (P<0.05 for all. The mean sphere and cylinder decreased significantly post-surgery from, -3.10±2.99 D to -0.11±0.93 D and from -3.68±1.53 to -1.11±0.75 D respectively, while the CDVA, CCT and coma showed no significant changes. Compared to post-ISCR, significant reductions (P<0.05 or all in all K values, sphere and cylinder were observed after TG-PRK/CXL.CONCLUSION:Same-day combined topography-guided PRK and corneal crosslinking following placement of ISCR is a safe and potentially effective option in treating low-moderate keratoconus. It significantly improves all visual acuity, reduced keratometry, sphere and astigmatism, but causes no change in central corneal thickness and coma.

  15. Bidirectional Tachycardia after an Acute Intravenous Administration of Digitalis for a Suicidal Gesture

    Directory of Open Access Journals (Sweden)

    Diletta Sabatini

    2014-01-01

    Full Text Available Acute digoxin intoxication is a life-threating condition associated with severe cardiotoxicity. Female gender, age, low lean body mass, hypertension, and renal insufficiency may worsen the prognosis. Arrhythmias caused by digitalis glycosides are characterized by an increased automaticity coupled with concomitant conduction delay. Bidirectional tachycardia is pathognomonic of digoxin intoxication, but it is rarely observed. An 83-year-old woman was admitted to the Emergency Department after self-administration of 5 mg of digoxin i.v. for suicidal purpose. Her digoxin serum concentration was 17.4 ng/mL. The patient developed a bidirectional tachycardia and the Poison Control Center of the hospital provided digoxin immune fab. Bidirectional tachycardia quickly reversed and the patient remained stable throughout the hospital stay. This case shows that a multiple disciplinary approach, involving cardiologists and toxicologists, is essential for the management of digoxin intoxication. The optimal treatment of this rare event depends on the clinical conditions and on the serum drug concentration of the patient. Digoxin immune fab represents a safe, effective, and specific method for rapidly reversing digitalis cardiotoxicity and should be started as soon as the diagnosis is defined.

  16. Bidirectional Associations between Peer Relations and Attention Problems from 9 to 16 Years.

    Science.gov (United States)

    Ji, Linqin; Pan, Bin; Zhang, Wenxin; Zhang, Liang; Chen, Liang; Deater-Deckard, Kirby

    2018-05-12

    We examined the bidirectional relations between peer relations and attention problems from middle childhood through adolescence. Using data from the Longitudinal Study of Chinese Children and Adolescents (LSCCA, N = 2157, 51.9% male), three key aspects of peer relations (acceptance, rejection, and victimization) were assessed annually from 9 to 16 years of age. Attention problems were assessed at 9 and 15 years. Latent growth modeling indicated that greater attention problems at age 9 were linked with a lower intercept for peer acceptance, and higher intercepts for rejection and victimization. Also, prior lower acceptance and greater rejection and victimization, along with a higher increase over time in rejection and lower decrease over time in victimization, predicted attention problems at age 15. Cross-lagged analysis showed that attention problems were associated with less subsequent peer acceptance and greater subsequent rejection and victimization. Only peer rejection (but neither victimization nor acceptance) predicted more subsequent attention problems. Findings point to bidirectional associations between attention problems and peer relations in the developmental transition across adolescence. Evidence for differential bidirectionality of attention problems with the multiple peer experience (group versus dyadic; good versus bad) emerged, and future replications are needed.

  17. Endoscopic tri-modal imaging for detection of early neoplasia in Barrett's oesophagus: a multi-centre feasibility study using high-resolution endoscopy, autofluorescence imaging and narrow band imaging incorporated in one endoscopy system

    NARCIS (Netherlands)

    Curvers, W. L.; Singh, R.; Song, L.-M. Wong-Kee; Wolfsen, H. C.; Ragunath, K.; Wang, K.; Wallace, M. B.; Fockens, P.; Bergman, J. J. G. H. M.

    2008-01-01

    OBJECTIVE: To investigate the diagnostic potential of endoscopic tri-modal imaging and the relative contribution of each imaging modality (i.e. high-resolution endoscopy (HRE), autofluorescence imaging (AFI) and narrow-band imaging (NBI)) for the detection of early neoplasia in Barrett's oesophagus.

  18. MECHANICAL AND THERMO–MECHANICAL PROPERTIES OF BI-DIRECTIONAL AND SHORT CARBON FIBER REINFORCED EPOXY COMPOSITES

    Directory of Open Access Journals (Sweden)

    G. AGARWAL

    2014-10-01

    Full Text Available This paper based on bidirectional and short carbon fiber reinforced epoxy composites reports the effect of fiber loading on physical, mechanical and thermo-mechanical properties respectively. The five different fiber loading, i.e., 10wt. %, 20wt. %, 30wt. %, 40wt. % and 50wt. % were taken for evaluating the above said properties. The physical and mechanical properties, i.e., hardness, tensile strength, flexural strength, inter-laminar shear strength and impact strength are determined to represent the behaviour of composite structures with that of fiber loading. Thermo-mechanical properties of the material are measured with the help of Dynamic Mechanical Analyser to measure the damping capacity of the material that is used to reduce the vibrations. The effect of storage modulus, loss modulus and tan delta with temperature are determined. Finally, Cole–Cole analysis is performed on both bidirectional and short carbon fiber reinforced epoxy composites to distinguish the material properties of either homogeneous or heterogeneous materials. The results show that with the increase in fiber loading the mechanical properties of bidirectional carbon fiber reinforced epoxy composites increases as compared to short carbon fiber reinforced epoxy composites except in case of hardness, short carbon fiber reinforced composites shows better results. Similarly, as far as Loss modulus, storage modulus is concerned bidirectional carbon fiber shows better damping behaviour than short carbon fiber reinforced composites.

  19. Evaluation of a bi-directional aluminum honeycomb impact limiter design

    International Nuclear Information System (INIS)

    Doman, M.J.

    1995-01-01

    A 120 Ton shipping cask is being developed for the on-site shipment of dry spent fuel at the Idaho National Engineering Laboratory. Impact limiters were incorporated in the cask design to limit the inertial load of the package and its contents during the hypothetical 9-meter (30-foot) drop accident required by 10CFR71. The design process included: (1) a series of static and dynamic tests to determine the crush characteristics of the bi-directional aluminum honeycomb impact limiter material, (2) the development of an analytical model to predict the cask deceleration force as a function of impact limiter crush, and (3) a series of quarter scale model drop tests to qualify the analytical model. The scale model testing, performed at Sandia National Laboratory in Albuquerque, New Mexico, revealed several design aspects which should be considered in developing bi-directional aluminum honeycomb impact limiters and several other design aspects which should be considered for impact limiter designs in general

  20. Bidirectional composition on lie groups for gradient-based image alignment.

    Science.gov (United States)

    Mégret, Rémi; Authesserre, Jean-Baptiste; Berthoumieu, Yannick

    2010-09-01

    In this paper, a new formulation based on bidirectional composition on Lie groups (BCL) for parametric gradient-based image alignment is presented. Contrary to the conventional approaches, the BCL method takes advantage of the gradients of both template and current image without combining them a priori. Based on this bidirectional formulation, two methods are proposed and their relationship with state-of-the-art gradient based approaches is fully discussed. The first one, i.e., the BCL method, relies on the compositional framework to provide the minimization of the compensated error with respect to an augmented parameter vector. The second one, the projected BCL (PBCL), corresponds to a close approximation of the BCL approach. A comparative study is carried out dealing with computational complexity, convergence rate and frequence of convergence. Numerical experiments using a conventional benchmark show the performance improvement especially for asymmetric levels of noise, which is also discussed from a theoretical point of view.