WorldWideScience

Sample records for saliva-alcohol test device

  1. 49 CFR 40.263 - What happens when an employee is unable to provide a sufficient amount of saliva for an alcohol...

    Science.gov (United States)

    2010-10-01

    ... sufficient amount of saliva for an alcohol screening test? (a) As the STT, you must take the following steps if an employee is unable to provide sufficient saliva to complete a test on a saliva screening device (e.g., the employee does not provide sufficient saliva to activate the device). (1) You must conduct...

  2. A device for the collection of submandibular saliva.

    Science.gov (United States)

    Hanning, Sara; Motoi, Lidia; Medlicott, Natalie; Swindells, Stephen

    2012-03-01

    The objective of this study was to describe the construction of a non-invasive device for the collection of submandibular saliva. Preliminary tests were carried out on saliva collected from a single donor in order to determine whether the rheological properties of submandibular saliva collected using the device were comparable to whole saliva collected using the expectoration (or 'spit') method. The device collected a lower quantity of saliva than that collected using the expectoration method. Stimulated saliva collected using the device had a pH close to that of unstimulated saliva because the sealed collection unit in the device minimised contamination. Saliva exhibited shear-thinning behaviour regardless of the method of collection, although that collected using the device was more viscous. The viscoelasticity of saliva collected using the two methods was different, probably as a result of differences in composition. This difference was greater with stimulated saliva. Despite the discrepancies between whole saliva and submandibular saliva, the device provides a non-invasive method for the collection of high-quality saliva over extended periods.

  3. 49 CFR 40.245 - What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD?

    Science.gov (United States)

    2010-10-01

    ... process, take the device from the employee (or if you were holding it, remove it from the employee's mouth... direct the employee to take a new test immediately, using another type of ASD (e.g., saliva device) or an... a breath tube ASD? (a) As the STT or BAT, you must take the following steps when using the saliva...

  4. Human Saliva Collection Devices for Proteomics: An Update

    Directory of Open Access Journals (Sweden)

    Zohaib Khurshid

    2016-06-01

    Full Text Available There has been a rapid growth in the interest and adaptation of saliva as a diagnostic specimen over the last decade, and in the last few years in particular, there have been major developments involving the application of saliva as a clinically relevant specimen. Saliva provides a “window” into the oral and systemic health of an individual, and like other bodily fluids, saliva can be analyzed and studied to diagnose diseases. With the advent of new, more sensitive technologies to detect smaller concentrations of analytes in saliva relative to blood levels, there have been a number of critical developments in the field that we will describe. In particular, recent advances in standardized saliva collection devices that were not available three to four years ago, have made it easy for safe, simple, and non-invasive collection of samples to be carried out from patients. With the availability of these new technologies, we believe that in the next decade salivary proteomics will make it possible to predict and diagnose oral as well as systemic diseases, cancer, and infectious diseases, among others. The aim of this article is to review recent developments and advances in the area of saliva specimen collection devices and applications that will advance the field of proteomics.

  5. 36 CFR 3.11 - When is testing for alcohol or drugs required?

    Science.gov (United States)

    2010-07-01

    ..., DEPARTMENT OF THE INTERIOR BOATING AND WATER USE ACTIVITIES § 3.11 When is testing for alcohol or drugs... procedures of the blood, breath, saliva or urine for the purpose of determining blood alcohol and/or drug... admissible in any related judicial proceeding. (2) Any test or tests for the presence of alcohol and drugs...

  6. Assessing genetic polymorphisms using DNA extracted from cells present in saliva samples

    Directory of Open Access Journals (Sweden)

    Nemoda Zsofia

    2011-12-01

    Full Text Available Abstract Background Technical advances following the Human Genome Project revealed that high-quality and -quantity DNA may be obtained from whole saliva samples. However, usability of previously collected samples and the effects of environmental conditions on the samples during collection have not been assessed in detail. In five studies we document the effects of sample volume, handling and storage conditions, type of collection device, and oral sampling location, on quantity, quality, and genetic assessment of DNA extracted from cells present in saliva. Methods Saliva samples were collected from ten adults in each study. Saliva volumes from .10-1.0 ml, different saliva collection devices, sampling locations in the mouth, room temperature storage, and multiple freeze-thaw cycles were tested. One representative single nucleotide polymorphism (SNP in the catechol-0-methyltransferase gene (COMT rs4680 and one representative variable number of tandem repeats (VNTR in the serotonin transporter gene (5-HTTLPR: serotonin transporter linked polymorphic region were selected for genetic analyses. Results The smallest tested whole saliva volume of .10 ml yielded, on average, 1.43 ± .77 μg DNA and gave accurate genotype calls in both genetic analyses. The usage of collection devices reduced the amount of DNA extracted from the saliva filtrates compared to the whole saliva sample, as 54-92% of the DNA was retained on the device. An "adhered cell" extraction enabled recovery of this DNA and provided good quality and quantity DNA. The DNA from both the saliva filtrates and the adhered cell recovery provided accurate genotype calls. The effects of storage at room temperature (up to 5 days, repeated freeze-thaw cycles (up to 6 cycles, and oral sampling location on DNA extraction and on genetic analysis from saliva were negligible. Conclusions Whole saliva samples with volumes of at least .10 ml were sufficient to extract good quality and quantity DNA. Using

  7. 21 CFR 862.3040 - Alcohol test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Alcohol test system. 862.3040 Section 862.3040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED....3040 Alcohol test system. (a) Identification. An alcohol test system is a device intented to measure...

  8. 21 CFR 862.3050 - Breath-alcohol test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breath-alcohol test system. 862.3050 Section 862.3050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened...

  9. Handheld Device Adapted to Smartphone Cameras for the Measurement of Sodium Ion Concentrations at Saliva-Relevant Levels via Fluorescence

    Directory of Open Access Journals (Sweden)

    Michelle Lipowicz

    2015-06-01

    Full Text Available The use of saliva sampling as a minimally-invasive means for drug testing and monitoring physiology is a subject of great interest to researchers and clinicians. This study describes a new optical method based on non-axially symmetric focusing of light using an oblate spheroid sample chamber. The device is simple, lightweight, low cost and is easily attached to several different brands/models of smartphones (Apple, Samsung, HTC and Nokia for the measurement of sodium ion levels at physiologically-relevant saliva concentrations. The sample and fluorescent reagent solutions are placed in a specially-designed, lightweight device that excludes ambient light and concentrates 470-nm excitation light, from a low-power photodiode, within the sample through non-axially-symmetric refraction. The study found that smartphone cameras and post-image processing quantitated sodium ion concentration in water over the range of 0.5–10 mM, yielding best-fit regressions of the data that agree well with a data regression of microplate luminometer results. The data suggest that fluorescence can be used for the measurement of salivary sodium ion concentrations in low-resource or point-of-care settings. With further fluorescent assay testing, the device may find application in a variety of enzymatic or chemical assays.

  10. Comparing Properties (Concentration, PH and mutans streptococcus Saliva in Both Status Resting Saliva and Stimulated Saliva in Preschoolers of Kerman city

    Directory of Open Access Journals (Sweden)

    Elham Farokh-Gisour,

    2016-08-01

    Full Text Available This paper aimed to compare the characteristics (concentration, PH and mutans streptococcus saliva in both status resting saliva and stimulated saliva in preschoolers of Kerman city. In this study, 100 children aged 5 years among patients admitted to the pediatric ward of Kerman dental school and dental offices, some experts in Kerman dental school participated. Resting and stimulated saliva (after chewing oral paraffin children collected and in concentrations, PH and the amount of mutans streptococcus was measured. Mc Nemar test to compare the frequency of positive and negative cultures before and after stimulation as well as paired t-test to compare the saliva pH and concentration of not stimulated saliva and stimulated saliva in two modes was used. The significance level was set less than 0.05.The mean resting salivary osmolality of the population: 30.42 ± 87.41 and the average salivary osmolality of the total population were 79.81. Osmolality differences in saliva before and after stimulation with each other was significant (p = 0.009, paired t-test. The mean of resting saliva in the total population PH 0.45 ± 7.78 and the average PH stimulated saliva in the total population was 8.22 and the difference before and after each significant (p = 0.02, paired t-test. In mutans streptococcus in test samples in all 71 patients (71% positive test and 29 patients (29% had a negative test that number of positive cultures are equal before and after stimulation of saliva and thus the difference between the two groups (p> 0.05 was observed. In terms of comparing the properties of resting and stimulated saliva can conclude that salivary stimulated PH was significantly higher than resting saliva. While stimulated saliva osmolality was significantly less than resting saliva and the frequency of positive test mutans streptococcus in saliva before and after stimulation had no significant difference (p> 0.05. This means that test results on samples of mutans

  11. Detection of anti-HIV-1 IgG antibodies in whole saliva by GACELISA and Western blot assays.

    Science.gov (United States)

    Matee, M I; Lyamuya, E F; Simon, E; Mbena, E C; Kagoma, C; Samaranayake, L P; Scheutz, F

    1996-05-01

    The present study, based on 158 HIV seropositives and 167 HIV seronegatives, demonstrates that saliva collected with the Omni-SAL device and tested with GACELISA (an IgG antibody capture ELISA) is an effective non-invasive alternative to serum for anti-HIV IgG antibody screening. The study also shows that a conventional serum Western blot kit can be used, with slight modifications, for confirmatory testing of saliva specimens. Collecting saliva with the Omni-SAL device had a very good acceptance rate among Tanzanian subjects, and although this diagnostic method is not yet known by the general public, 65% of the study participants preferred to give saliva instead of blood for HIV testing.

  12. Electrochemical behavior and pH stability of artificial salivas for corrosion tests.

    Science.gov (United States)

    Queiroz, Gláucia Maria Oliveira de; Silva, Leandro Freitas; Ferreira, José Tarcísio Lima; Gomes, José Antônio da Cunha P; Sathler, Lúcio

    2007-01-01

    It is assumed that the compositions of artificial salivas are similar to that of human saliva. However, the use of solutions with different compositions in in vitro corrosion studies can lead dissimilar electrolytes to exhibit dissimilar corrosivity and electrochemical stability. This study evaluated four artificial salivas as regards pH stability with time, redox potentials and the polarization response of an inert platinum electrode. The tested solutions were: SAGF medium, Mondelli artificial saliva, UFRJ artificial saliva (prepared at the School of Pharmacy, Federal University of Rio de Janeiro, RJ, Brazil) and USP-RP artificial saliva (prepared at the School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, SP, Brazil). It was observed that pH variations were less than 1 unit during a 50-hour test. The SAGF medium, and the UFRJ and USP-RP solutions exhibited more oxidizing characteristics, whereas the Mondelli solution presented reducing properties. Anodic polarization revealed oxidation of the evaluated electrolytes at potentials below +600 mV SCE. It was observed that the UFRJ and USP-RP solutions presented more intense oxidation and reduction processes as compared to the Mondelli and SAGF solutions.

  13. Influence of Alcohol and Alcohol-free Mouthrinses on Force Degradation of Different Types of Space Closure Auxiliaries used in Sliding Mechanics

    Directory of Open Access Journals (Sweden)

    Vivek Mahajan

    2014-01-01

    Full Text Available Introduction: The objective of the study was to evaluate the percentage of force degradation of elastomeric chains, NiTi closed coil spring and stainless steel closed coil spring at different time intervals in different media. Materials and methods: Three types of space closing auxiliaries, such as elastomeric chains, NiTi closed coil springs and stainless steel coil springs immersed in artificial saliva, alcohol-free mouthrinse (Colgate plax and alcohol-containing mouthrinse (Listerine at time interval of 1, 4, 7,14, 21 and 28 days were divided into nine groups of 15 each: Group I- 15 polyurethane elastomeric chain immersed inside artificial saliva (Control. Group II-15 polyurethane elastomeric chain immersed inside alcohol-free mouthrinse. Group III- 15 polyurethane elastomeric chain immersed inside alcohol-containing mouthrinse. Group IV-15 stainless steel closed coil springs immersed inside artificial saliva (Control. Group V- 15 stainless steel closed coil springs immersed inside alcohol-free mouthrinse. Group VI-15 stainless steel closed coil springs immersed inside alcohol-containing mouthrinse. Group VII- 15 NiTi closed coil springs immersed inside artificial saliva (Control. Group VIII-15 nickel titanium closed coil springs immersed inside alcohol-free mouthrinse. Group IX- 15 NiTi closed coil springs immersed inside alcohol-containing mouthrinse. The percentage of force degradation was measured with the universal testing machine. Results: The force produced by elastomeric chain, stainless steel closed coil spring and NiTi closed coil spring at seven time intervals in artificial saliva, alcohol-free mouthwash and alcohol-containing mouthwash showed a statistically significant difference (p < 0.001. Conclusion: The force degradation in alcohol-containing mouthwash solution (Listerine is more as compared to alcohol-free mouthwash solution (Colgate plax .

  14. Longitudinal Study of Hepatitis A Infection by Saliva Sampling: The Kinetics of HAV Markers in Saliva Revealed the Application of Saliva Tests for Hepatitis A Study

    Science.gov (United States)

    Amado Leon, Luciane Almeida; de Almeida, Adilson José; de Paula, Vanessa Salete; Tourinho, Renata Santos; Villela, Daniel Antunes Maciel; Gaspar, Ana Maria Coimbra; Lewis-Ximenez, Lia Laura; Pinto, Marcelo Alves

    2015-01-01

    Despite the increasing numbers of studies investigating hepatitis A diagnostic through saliva, the frequency and the pattern of hepatitis A virus (HAV) markers in this fluid still remains unknown. To address this issue, we carried on a longitudinal study to examine the kinetics of HAV markers in saliva, in comparison with serum samples. The present study followed-up ten patients with acute hepatitis A infection during 180 days post diagnosis (dpd). Total anti-HAV was detected in paired serum and saliva samples until the end of the follow-up, showing a peak titer at 90th. However, total anti-HAV level was higher in serum than in saliva samples. This HAV marker showed a probability of 100% to be detected in both serum and saliva during 180 dpd. The IgM anti-HAV could be detected in saliva up to 150 dpd, showing the highest frequency at 30th, when it was detected in all individuals. During the first month of HAV infection, this acute HAV marker showed a detection probability of 100% in paired samples. The detection of IgM anti-HAV in saliva was not dependent on its level in serum, HAV-RNA detection and/or viral load, since no association was found between IgM anti-HAV positivity in saliva and any of these parameter (p>0.05). Most of the patients (80%) were found to contain HAV-RNA in saliva, mainly at early acute phase (30th day). However, it was possible to demonstrate the HAV RNA presence in paired samples for more than 90 days, even after seroconversion. No significant relationship was observed between salivary HAV-RNA positivity and serum viral load, demonstrating that serum viral load is not predictive of HAV-RNA detection in saliva. Similar viral load was seen in paired samples (on average 104 copies/mL). These data demonstrate that the best diagnostic coverage can be achieved by salivary anti-HAV antibodies and HAV-RNA tests during 30–90 dpd. The long detection and high probability of specific-HAV antibodies positivity in saliva samples make the assessment of

  15. Detection of illicit drugs in impaired driver saliva by a field-usable SERS analyzer

    Science.gov (United States)

    Shende, Chetan; Huang, Hermes; Farquharson, Stuart

    2014-05-01

    One of the greatest dangers of drug use is in combination with driving. According to the most recent National Highway Traffic Safety Administration (NHTSA) studies, more than 11% of drivers tested positive for illicit drugs, while 18% of drivers killed in accidents tested positive for illicit, prescription or over-the-counter drugs. Consequently, there is a need for a rapid, noninvasive, roadside drug testing device, similar to the breathalyzers used by law enforcement officials to estimate blood alcohol levels of impaired drivers. In an effort to satisfy this need we have been developing a sampling kit that allows extraction of drugs from 1 mL of saliva and detection by surfaceenhanced Raman spectroscopy using a portable Raman analyzer. Here we describe the development of the sampling kit and present measurements of diazepam at sub μg/mL concentrations measured in ~15 minutes.

  16. Handheld Device Adapted to Smartphone Cameras for the Measurement of Sodium Ion Concentrations at Saliva-Relevant Levels via Fluorescence

    OpenAIRE

    Lipowicz, Michelle; Garcia, Antonio

    2015-01-01

    The use of saliva sampling as a minimally-invasive means for drug testing and monitoring physiology is a subject of great interest to researchers and clinicians. This study describes a new optical method based on non-axially symmetric focusing of light using an oblate spheroid sample chamber. The device is simple, lightweight, low cost and is easily attached to several different brands/models of smartphones (Apple, Samsung, HTC and Nokia) for the measurement of sodium ion levels at physiologi...

  17. A novel one-step Helicobacter pylori saliva antigen test.

    Science.gov (United States)

    Yang, Bi-Ling; Yeh, Chun; Kwong, Wei-Gang; Lee, Shou-Dong

    2015-02-01

    A rapid, reliable, and sufficiently accurate test for diagnosing Helicobacter pylori infection is required for screening dyspeptic patients before a referral for endoscopy. The purpose of this article is two-fold: first, to evaluate the accuracy of a one-step H. pylori saliva antigen (HPS) test; and second, to compare noninvasive and invasive H. pylori tests in Taiwanese population. A total of 104 consecutive dyspeptic patients admitted for gastroenterology into the outpatient department underwent a one-step HPS test, rapid urease test, histology, and (13)C-urea breath test (13)C-UBT (proto C-13 urea kit). The accuracy of the HPS test was compared with a gold standard defined by at least two positive H. pylori test results from three H. pylori tests (histology, rapid urease test, and (13)C-UBT). The 104 patients eligible for analysis (mean age: 58 years, range 22-87 years), 21 (20%) were gold standard positive. Among them, the positive of the one-step H. pylori saliva Ag test, rapid urease test, (13)C-UBT, histology were (52; 50%), (17; 16%), (27; 25%) and (22; 21%) respectively. The sensitivity and specificity of the HPS tests, rapid urease test, (13)C-UBTs, and histology were 71.43% and 55.42%, 76.19% and 98.80%, 100% and 92.77%, and 85.71% and 95.18%, respectively, relative to the gold standard. The one-step HPS test exhibited a sensitivity of 71.43%, nearly equivalent to that of the rapid urea test. The one-step HPS test exhibited a high sensitivity and low specificity compared with the other tests, indicating that it is not sufficiently accurate for use in a clinical setting for diagnosing H. pylori infection. However, the test is simple to use (requiring only a saliva sample), inexpensive, and noninvasive in its application, and thus appealing for use in population-based prevalence surveys of the epidemiology of H. pylori infection. Copyright © 2014. Published by Elsevier Taiwan.

  18. Effects of saliva collection using cotton swabs on melatonin enzyme immunoassay

    Directory of Open Access Journals (Sweden)

    Katsuura Tetsuo

    2011-01-01

    Full Text Available Abstract Background Although various acceptable and easy-to-use devices have been used for saliva collection, cotton swabs are among the most common ones. Previous studies reported that cotton swabs yield a lower level of melatonin detection. However, this statistical method is not adequate for detecting an agreement between cotton saliva collection and passive saliva collection, and a test for bias is needed. Furthermore, the effects of cotton swabs have not been examined at lower melatonin level, a level at which melatonin is used for assessment of circadian rhythms, namely dim light melatonin onset (DLMO. In the present study, we estimated the effect of cotton swabs on the results of salivary melatonin assay using the Bland-Altman plot at lower level. Methods Nine healthy males were recruited and each provided four saliva samples on a single day to yield a total of 36 samples. Saliva samples were directly collected in plastic tubes using plastic straws, and subsequently pipetted onto cotton swabs (cotton saliva collection and into clear sterile tubes (passive saliva collection. The melatonin levels were analyzed in duplicate using commercially available ELISA kits. Results The mean melatonin concentration in cotton saliva collection samples was significantly lower than that in passive saliva collection samples at higher melatonin level (>6 pg/mL. The Bland-Altman plot indicated that cotton swabs causes relative and proportional biases in the assay results. For lower melatonin level ( Conclusion Our findings indicate an interference effect of cotton swabs on the assay result of salivary melatonin at lower melatonin level. Cotton-based collection devices might, thus, not be suitable for assessment of DLMO.

  19. Effects of saliva collection using cotton swabs on melatonin enzyme immunoassay.

    Science.gov (United States)

    Kozaki, Tomoaki; Lee, Soomin; Nishimura, Takayuki; Katsuura, Tetsuo; Yasukouchi, Akira

    2011-01-10

    Although various acceptable and easy-to-use devices have been used for saliva collection, cotton swabs are among the most common ones. Previous studies reported that cotton swabs yield a lower level of melatonin detection. However, this statistical method is not adequate for detecting an agreement between cotton saliva collection and passive saliva collection, and a test for bias is needed. Furthermore, the effects of cotton swabs have not been examined at lower melatonin level, a level at which melatonin is used for assessment of circadian rhythms, namely dim light melatonin onset (DLMO). In the present study, we estimated the effect of cotton swabs on the results of salivary melatonin assay using the Bland-Altman plot at lower level. Nine healthy males were recruited and each provided four saliva samples on a single day to yield a total of 36 samples. Saliva samples were directly collected in plastic tubes using plastic straws, and subsequently pipetted onto cotton swabs (cotton saliva collection) and into clear sterile tubes (passive saliva collection). The melatonin levels were analyzed in duplicate using commercially available ELISA kits. The mean melatonin concentration in cotton saliva collection samples was significantly lower than that in passive saliva collection samples at higher melatonin level (>6 pg/mL). The Bland-Altman plot indicated that cotton swabs causes relative and proportional biases in the assay results. For lower melatonin level (<6 pg/mL), although the BA plots didn't show proportional and relative biases, there was no significant correlation between passive and cotton saliva collection samples. Our findings indicate an interference effect of cotton swabs on the assay result of salivary melatonin at lower melatonin level. Cotton-based collection devices might, thus, not be suitable for assessment of DLMO.

  20. A novel one-step Helicobacter pylori saliva antigen test

    Directory of Open Access Journals (Sweden)

    Bi-Ling Yang

    2015-02-01

    Conclusion: The one-step HPS test exhibited a high sensitivity and low specificity compared with the other tests, indicating that it is not sufficiently accurate for use in a clinical setting for diagnosing H. pylori infection. However, the test is simple to use (requiring only a saliva sample, inexpensive, and noninvasive in its application, and thus appealing for use in population-based prevalence surveys of the epidemiology of H. pylori infection.

  1. Electrochemical behavior and pH stability of artificial salivas for corrosion tests Comportamento eletroquímico e estabilidade de pH de salivas artificiais para testes de corrosão

    Directory of Open Access Journals (Sweden)

    Gláucia Maria Oliveira de Queiroz

    2007-09-01

    Full Text Available It is assumed that the compositions of artificial salivas are similar to that of human saliva. However, the use of solutions with different compositions in in vitro corrosion studies can lead dissimilar electrolytes to exhibit dissimilar corrosivity and electrochemical stability. This study evaluated four artificial salivas as regards pH stability with time, redox potentials and the polarization response of an inert platinum electrode. The tested solutions were: SAGF medium, Mondelli artificial saliva, UFRJ artificial saliva (prepared at the School of Pharmacy, Federal University of Rio de Janeiro, RJ, Brazil and USP-RP artificial saliva (prepared at the School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, SP, Brazil. It was observed that pH variations were less than 1 unit during a 50-hour test. The SAGF medium, and the UFRJ and USP-RP solutions exhibited more oxidizing characteristics, whereas the Mondelli solution presented reducing properties. Anodic polarization revealed oxidation of the evaluated electrolytes at potentials below +600 mV SCE. It was observed that the UFRJ and USP-RP solutions presented more intense oxidation and reduction processes as compared to the Mondelli and SAGF solutions.Admite-se que as composições das salivas artificiais são semelhantes àquela da saliva humana. A utilização de soluções de composições distintas em estudos de corrosão in vitro, entretanto, pode fazer com que eletrólitos diferentes exibam diferenças no processo corrosivo e na estabilidade eletroquímica. Este estudo avaliou quatro salivas artificiais em relação a estabilidade do pH em função do tempo, potencial redox e resposta à polarização de um eletrodo de platina inerte. As soluções testadas foram: meio SAGF, saliva artificial Mondelli, saliva artificial UFRJ (preparada pela Faculdade de Farmácia da Universidade Federal do Rio de Janeiro, RJ, Brasil e saliva artificial USP-RP (preparada pela

  2. Evaluation of three rapid oral fluid test devices on the screening of multiple drugs of abuse including ketamine.

    Science.gov (United States)

    Tang, Magdalene H Y; Ching, C K; Poon, Simon; Chan, Suzanne S S; Ng, W Y; Lam, M; Wong, C K; Pao, Ronnie; Lau, Angus; Mak, Tony W L

    2018-05-01

    Rapid oral fluid testing (ROFT) devices have been extensively evaluated for their ability to detect common drugs of abuse; however, the performance of such devices on simultaneous screening for ketamine has been scarcely investigated. The present study evaluated three ROFT devices (DrugWipe ® 6S, Ora-Check ® and SalivaScreen ® ) on the detection of ketamine, opiates, methamphetamine, cannabis, cocaine and MDMA. A liquid chromatography tandem mass spectrometry (LCMS) assay was firstly established and validated for confirmation analysis of the six types of drugs and/or their metabolites. In the field test, the three ROFT devices were tested on subjects recruited from substance abuse clinics/rehabilitation centre. Oral fluid was also collected using Quantisal ® for confirmation analysis. A total of 549 samples were collected in the study. LCMS analysis on 491 samples revealed the following drugs: codeine (55%), morphine (49%), heroin (40%), methamphetamine (35%), THC (8%), ketamine (4%) and cocaine (2%). No MDMA-positive cases were observed. Results showed that the overall specificity and accuracy were satisfactory and met the DRUID standard of >80% for all 3 devices. Ora-Check ® had poor sensitivities (ketamine 36%, methamphetamine 63%, opiates 53%, cocaine 60%, THC 0%). DrugWipe ® 6S showed good sensitivities in the methamphetamine (83%) and opiates (93%) tests but performed relatively poorly for ketamine (41%), cocaine (43%) and THC (22%). SalivaScreen ® also demonstrated good sensitivities in the methamphetamine (83%) and opiates (100%) tests, and had the highest sensitivity for ketamine (76%) and cocaine (71%); however, it failed to detect any of the 28 THC-positive cases. The test completion rate (proportion of tests completed with quality control passed) were: 52% (Ora-Check ® ), 78% (SalivaScreen ® ) and 99% (DrugWipe ® 6S). Copyright © 2018 Elsevier B.V. All rights reserved.

  3. evaluation of a rapid test for hiv antibodies in saliva and blood

    African Journals Online (AJOL)

    To test whole blood and saliva for HIV antibodies. (anti-HIV) using a rapid test strip capillary flow . immunoassay ... Design. A prospective pilot study of selected HIV-positive and ... defined by the underlying illness or condition is illustrated in.

  4. Erosion protection conferred by whole human saliva, dialysed saliva, and artificial saliva

    Science.gov (United States)

    Baumann, T.; Kozik, J.; Lussi, A.; Carvalho, T. S.

    2016-10-01

    During dental erosion, tooth minerals are dissolved, leading to a softening of the surface and consequently to irreversible surface loss. Components from human saliva form a pellicle on the tooth surface, providing some protection against erosion. To assess the effect of different components and compositions of saliva on the protective potential of the pellicle against enamel erosion, we prepared four different kinds of saliva: human whole stimulated saliva (HS), artificial saliva containing only ions (AS), human saliva dialysed against artificial saliva, containing salivary proteins and ions (HS/AS), and human saliva dialysed against deionised water, containing only salivary proteins but no ions (HS/DW). Enamel specimens underwent four cycles of immersion in either HS, AS, HS/AS, HS/DW, or a humid chamber (Ctrl), followed by erosion with citric acid. During the cycling process, the surface hardness and the calcium released from the surface of the specimens were measured. The different kinds of saliva provided different levels of protection, HS/DW exhibiting significantly better protection than all the other groups (p < 0.0001). Different components of saliva, therefore, have different effects on the protective properties of the pellicle and the right proportions of these components in saliva are critical for the ability to form a protective pellicle.

  5. Bacterial profiles of saliva in relation to diet, lifestyle factors, and socioeconomic status

    Directory of Open Access Journals (Sweden)

    Daniel Belstrøm

    2014-04-01

    Full Text Available Background and objective: The bacterial profile of saliva is composed of bacteria from different oral surfaces. The objective of this study was to determine whether different diet intake, lifestyle, or socioeconomic status is associated with characteristic bacterial saliva profiles. Design: Stimulated saliva samples from 292 participants with low levels of dental caries and periodontitis, enrolled in the Danish Health Examination Survey (DANHES, were analyzed for the presence of approximately 300 bacterial species by means of the Human Oral Microbe Identification Microarray (HOMIM. Using presence and levels (mean HOMIM-value of bacterial probes as endpoints, the influence of diet intake, lifestyle, and socioeconomic status on the bacterial saliva profile was analyzed by Mann–Whitney tests with Benjamini–Hochberg's correction for multiple comparisons and principal component analysis. Results: Targets for 131 different probes were identified in 292 samples, with Streptococcus and Veillonella being the most predominant genera identified. Two bacterial taxa (Streptococcus sobrinus and Eubacterium [11][G-3] brachy were more associated with smokers than non-smokers (adjusted p-value<0.01. Stratification of the group based on extreme ends of the parameters age, gender, alcohol consumption, body mass index (BMI, and diet intake had no statistical influence on the composition of the bacterial profile of saliva. Conversely, differences in socioeconomic status were reflected by the bacterial profiles of saliva. Conclusions: The bacterial profile of saliva seems independent of diet intake, but influenced by smoking and maybe socioeconomic status.

  6. Evaluation of a rapid test for HIV antibodies in saliva and blood ...

    African Journals Online (AJOL)

    Objective. To test whole blood and saliva for HIV antibodies (anti-HIV) using a rapid test strip capillary flow . immunoassay, and to correlate the test strip results with blood specimen results obtained from routine diagnostic antiHIV assays. Design. A prospective pilot study of selected HIV-positive and HIV-negative individuals ...

  7. Methods for transfer a saliva based alcohol content test to a dermal patch

    Energy Technology Data Exchange (ETDEWEB)

    Silks, III, Louis A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-03

    Detection and quantitation of ethanol which is highly sensitive, specific, and efficient has been a commercial target for sometime. Clearly analytical methods are useful such as gas and liquid chromatography, mass spectrometry, and NMR spectroscopy. However, those methods are best used in the laboratory and a less useful for detection and quantitation of ethanol in the field. Enzymes have been employed for the detection and quantitation of EtOH. Enzymes are proteins that perform a particular task in a bio-catalytic way. Most of the chemistry that these enzymes do are frequently exquisitely specific in that only one alcohol reacts and only one product is produced. One enzyme molecule can catalyze the reaction of numerous substrate molecules which in itself is an amplification of the recognition signal. Alcohol dehydrogenase (ADH) and alcohol oxidase (AO) are two possible enzymatic targets for EtOH sensor development.1 The ADH oxidizes the alcohol using a co-factor nicotinamide adenine dinucleotide. This co-factor needs to be within close proximity of the ADH. AO also oxidizes the ethanol using molecular oxygen giving rise to the production of the aldehyde and hydrogen peroxide.

  8. Detection of phencyclidine usage by radioimmunoassay of saliva

    International Nuclear Information System (INIS)

    McCarron, M.M.; Walberg, C.B.; Soares, J.R.; Gross, S.J.; Baselt, R.C.

    1984-01-01

    Paired serum and saliva samples, obtained from 100 emergency department patients suspected of phencyclidine (PCP) intoxication, were analyzed using a specific PCP radioimmunoassay (RIA). Seventy-four of the 100 saliva samples and 75 of the paired serum samples were positive for PCP. The final clinical diagnosis was PCP intoxication in 79 cases. Of these, both serum and saliva tests were positive in 70 cases, only serum was positive in two cases, and both serum and saliva samples were negative in seven cases. The concentration of PCP in the samples did not correlate with the severity of PCP intoxication. In the remaining 21 cases, with no clinical evidence of PCP intoxication, PCP assays were negative in both serum and saliva in 17 cases, three patients had positive saliva and serum tests, and one other patient had a positive PCP saliva assay. Thus, saliva would appear to be as reliable as serum as a specimen for PCP analysis

  9. Control device of air-fuel ratio of alcohol-gasoline mixed fuel

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Kazuo

    1987-08-19

    Concerning alcohol-gasoline mixed fuel, even the same amount of the fuel shows different air-fuel ratio depending upon alcohol concentration in the fuel, accordingly it is required to know the alcohol concentration when it is intended to make the air-fuel ratio to be the same as the predetermined ratio. Although a sensor which can detect in quick response and exactly the alcohol concentration has not been developed, the alcohol concentration in gasoline can be detected by detecting the concentration of the water in exhaust gas and many hygrometers which can detect the concentration of the water with high precision are available. With regard to an internal combustion engine equipped with a fuel supply device in order to supply alcohol-gasoline mixed fuel into an engine suction passage, this invention offers an air-fuel ratio control device to control the amount of the fuel to be supplied from the fuel supply device by detecting the concentration of alcohol in the gasoline from among the output signals of the main hygrometer and the auxiliary hygrometer. The former hygrometer to detect the concentration of the water in the exhaust gas is set in the engine exhaust gas passage and the latter is installed to detect the concentration of the water in the air. (4 figs)

  10. Anti-inflammatory and antinociceptive activities of Rhipicephalus microplus saliva

    Directory of Open Access Journals (Sweden)

    D F Buccini

    2018-01-01

    Full Text Available Objective: To evaluate the antinociceptive and anti-inflammatory activities and the toxic effects of Rhipicephalus microplus saliva for elucidating the modulation mechanism between arthropod saliva and host. Methods: For saliva collection, engorged ticks were obtained from a controlled bovine infestation and collected by natural fall. The ticks were fixed and injected pilocarpine 0.2% for induction of salivation. Saliva was collected, lyophilized and stored at - 80 °C. Cytotoxic activity was assessed by the hemolysis method (25, 50, 100, 200 and 300 μ g/mL and MTT cell viability assay (2.5, 5, 10, 20 and 40 μ g/mL for 24, 48 and 72 h. Anti-inflammatory activity was evaluated using the method of neutrophil migration to the peritoneal cavity of mice at doses of 10, 15 and 20 mg/kg; antinociceptive activity was assessed using the acetic acid-induced writhing test, and formalin-induced paw-licking in mice at dose of 15 mg/kg. Results: Saliva did not cause erythrocytes hemolysis at any concentration tested, as well as did not decrease cell viability in the MTT assay. Saliva inhibited neutrophil migration by 87% and 73% at doses of 15 and 20 mg/kg, respectively. In the nociceptive tests, saliva presented analgesic activity of 69.96% in the abdominal writhing test, and of 84.41% in the formalin test. Conclusions: The study proves that Rhipicephalus microplus saliva has significant in vivo anti-inflammatory and antinociceptive activities. The data presented herein support the development of further studies to elucidate the active principles of Rhipicephalus microplus saliva and its mechanism of action and, in future, to develop novel anti-inflammatory and analgesic drugs.

  11. Caries prevalence in chronic alcoholics and the relationship to salivary flow rate and pH.

    Science.gov (United States)

    Dukić, Walter; Dobrijević, Tanja Trivanović; Katunarić, Marina; Lesić, Stjepanka

    2013-03-01

    The aim of this study was to investigate the dental status of alcoholics; to evaluate the relationship of unstimulated and stimulated saliva pH on their decayed/missing/filled teeth (DMFT); and to evaluate the relationship of unstimulated and stimulated salivary flow rate on their DMFT. A cross-sectional study was conducted in patients treated for alcohol dependency (n = 70; mean age 41.7 years) and a control group of non-alcoholics (n = 70; mean age 39.1 years). Examinations for dental caries were conducted using the World Health Organization (WHO) criteria and questionnaires. The correlation between nominal variables was determined using chi2 test (alpha = 0.05). The correlation between interval variables was determined using Pearson's correlation coefficient. The mean DMFT was similar in alcoholics (14.40) and the control group (13.44) (p > 0.05). There was a statistically significant correlation between alcoholism and unstimulated salivary flow rate (p salivary flow rate (p > 0.05) or stimulated salivary flow on DMFT (p > 0.05). There was a statistically significant correlation between alcoholism and the pH value of stimulated saliva (p 0.05). No major differences were found with respect to overall DMFT in alcoholics compared to the control group. Alcoholism and stimulated salivary flow rate showed no correlation. Unstimulated salivary flow rate as well as the pH values of both unstimulated and stimulated saliva, were lower in the alcoholic group.

  12. Analysis for drugs in saliva and breath

    Science.gov (United States)

    1981-09-25

    Collection devices for saliva and breath that involved non-invasive techniques for sample collection were evaluated. Having subjects simply spit into a specially prepared glass vial was found to be an efficient, inexpensive and simple way to collect ...

  13. Analysis for drug in saliva and breath

    Science.gov (United States)

    1981-09-25

    Collection devices for saliva and breath that involved non-invasive : techniques for sample collection were evaluated. Having subjects simply : spit into a specially prepared glass vial was found to be an efficient, : inexpensive and simple way to co...

  14. Application of graphene oxide-poly (vinyl alcohol) polymer nanocomposite for memory devices

    Science.gov (United States)

    Kaushal, Jyoti; Kaur, Ravneet; Sharma, Jadab; Tripathi, S. K.

    2018-05-01

    Significant attention has been gained by polymer nanocomposites because of their possible demands in future electronic memory devices. In the present work, device based on Graphene Oxide (GO) and polyvinyl alcohol (PVA) has been made and examined for the memory device application. The prepared Graphene oxide (GO) and GO-PVA nanocomposite (NC) has been characterized by X-ray Diffraction (XRD). GO nanosheets show the diffraction peak at 2θ = 11.60° and the interlayer spacing of 0.761 nm. The XRD of GO-PVA NC shows the diffraction peak at 2θ =18.56°. The fabricated device shows bipolar switching behavior having ON/OFF current ratio ˜102. The Write-Read-Erase-Read (WRER) cycles test shows that the Al/GO-PVA/Ag device has good stability and repeatability.

  15. 77 FR 35745 - Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in...

    Science.gov (United States)

    2012-06-14

    ..., battery powered device with a semiconductor sensor. (2) Alcohol Countermeasure Systems Corp., submitted...-0062] Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in... Screening Devices to Measure Alcohol in Bodily Fluids dated, March 31, 2008 (73 FR 16956). DATES: Effective...

  16. Effects of saliva collection using cotton swab on cortisol enzyme immunoassay.

    Science.gov (United States)

    Kozaki, Tomoaki; Hashiguchi, Nobuko; Kaji, Yumi; Yasukouchi, Akira; Tochihara, Yutaka

    2009-12-01

    Cotton swabs are among the most commonly used devices for collecting saliva, but various studies have reported that their use impacts the results of salivary cortisol assays. These studies, however, estimated this impact by comparing the average of the concentration and/or scatter plots. In the present study, we estimated the impact of cotton swabs on the results of salivary cortisol enzyme immunoassay (EIA) by Bland-Altman plot. Eight healthy males (aged 20-23 years) provided four saliva samples on different days to yield a total of 32 samples. Saliva samples were collected directly in plastic tubes using plastic straws and then pipetted onto cotton swabs (cotton saliva collection) and into clear sterile tubes (passive saliva collection). There was a lower correlation between cotton and passive saliva collection. Individually, four subjects showed a negative correlation between passive and cotton saliva collection. A Bland-Altman plot indicated that cotton swabs causes a proportional bias on the EIA assay result. Our findings indicate a considerable effect of using cotton swabs for saliva collection, and subject-specific variability in the impact. A Bland-Altman plot further suggests possible reasons for this effect.

  17. An evaluation of saliva as an alternative to plasma for the detection of hepatitis C virus antibodies

    Directory of Open Access Journals (Sweden)

    Moorthy M

    2008-01-01

    Full Text Available Purpose: Seroepidemiological studies on the prevalence of Hepatitis C virus (HCV in India have been hampered by reluctance of subjects to provide blood samples for testing. We evaluated the use of saliva as an alternate specimen to blood for the detection of antibodies to HCV. Methods: Chronic liver disease (CLD patients attending the liver clinic were recruited for this study. A saliva and plasma sample (sample pair was collected from each patient included in the study. Saliva samples were collected using a commercially available collection device - OmniSal. Sample pairs were tested with an in-use ELISA for the detection of antibodies to HCV (HCV-Ab, with a minor modification in the manufacturer′s protocol while testing saliva. The cut-off absorbance value for declaring a sample as positive was determined by receiver operating curve (ROC analysis. HCV-Ab positivity in saliva was compared with that in plasma as well as with viral load in plasma and infecting genotype of the virus. Sensitivity, specificity, positive and negative predictive values, and correlation coefficients were calculated using Medcalc statistical software. Results: The optimal accuracy indices were: sensitivity-81.6%; specificity-92.5%; PPV-85.1% and NPV-90.5%. No correlation was found between salivary positivity and HCV viral load in plasma or infecting genotype. Conclusions: The accuracy indices indicate that the assay must be optimized further before it can be recommended for routine use in epidemiological surveys for HCV-Ab.

  18. Evaluation of HBsAg and anti-HBc assays in saliva and dried blood spot samples according HIV status.

    Science.gov (United States)

    Flores, Geane Lopes; Cruz, Helena Medina; Potsch, Denise Vigo; May, Silvia Beatriz; Brandão-Mello, Carlos Eduardo; Pires, Marcia Maria Amendola; Pilotto, Jose Henrique; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2017-09-01

    Influence of HIV status in HBV markers detection in saliva and dried blood spots (DBS) was not well established. This study aims to evaluate the performance of optimized commercial immunoassay for identifying HBsAg and anti-HBc in saliva and DBS according HIV status. A sum of 535 individuals grouped as HIV + , HBV + , HIV/HBV + and HIV/HBV- were recruited where 347 and 188 were included for HBsAg and anti-HBc evaluation, respectively. Serum, DBS collected in Whatman 903 paper and saliva obtained using salivette device were analyzed using EIA. Increased sample volume and ROC curve analysis for cut off determination were used for DBS and saliva testing. HBsAg detection in saliva and DBS exhibited sensitivities of 80.9% and 85.6% and specificities of 86.8% and 96.3%. Sensitivity of anti-HBc in saliva and DBS were 82.4% and 76.9% and specificities in saliva and DBS were 96.9% and 91.7%. Low sensitivities were observed for HBsAg (62%) and anti-HBc (47%) detection in saliva of HIV/HBV+ individuals. OD values were also lower for HBsAg detection in DBS and saliva of HIV/HBV+ individuals compared to their serum samples. Statistical significance was found for sensitivities in HBsAg detection between saliva and DBS demonstrating high sensitivity for DBS specimens. In conclusion, HIV status or antiretroviral treatment appears to interfere in the performance of HBsAg and anti-HBc detection in DBS and saliva samples using the adapted commercial EIA. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Diurnal patterns of salivary cortisol and DHEA using a novel collection device: electronic monitoring confirms accurate recording of collection time using this device.

    Science.gov (United States)

    Laudenslager, Mark L; Calderone, Jacqueline; Philips, Sam; Natvig, Crystal; Carlson, Nichole E

    2013-09-01

    The accurate indication of saliva collection time is important for defining the diurnal decline in salivary cortisol as well as characterizing the cortisol awakening response. We tested a convenient and novel collection device for collecting saliva on strips of filter paper in a specially constructed booklet for determination of both cortisol and DHEA. In the present study, 31 healthy adults (mean age 43.5 years) collected saliva samples four times a day on three consecutive days using filter paper collection devices (Saliva Procurement and Integrated Testing (SPIT) booklet) which were maintained during the collection period in a large plastic bottle with an electronic monitoring cap. Subjects were asked to collect saliva samples at awakening, 30 min after awakening, before lunch and 600 min after awakening. The time of awakening and the time of collection before lunch were allowed to vary by each subjects' schedule. A reliable relationship was observed between the time recorded by the subject directly on the booklet and the time recorded by electronic collection device (n=286 observations; r(2)=0.98). However, subjects did not consistently collect the saliva samples at the two specific times requested, 30 and 600 min after awakening. Both cortisol and DHEA revealed diurnal declines. In spite of variance in collection times at 30 min and 600 min after awakening, the slope of the diurnal decline in both salivary cortisol and DHEA was similar when we compared collection tolerances of ±7.5 and ±15 min for each steroid. These unique collection booklets proved to be a reliable method for recording collection times by subjects as well as for estimating diurnal salivary cortisol and DHEA patterns. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Comparison of Plasma, Saliva, and Hair Levetiracetam Concentrations.

    Science.gov (United States)

    Karaś-Ruszczyk, Katarzyna; Kuczyńska, Julita; Sienkiewicz-Jarosz, Halina; Kurkowska-Jastrzębska, Iwona; Bienkowski, Przemyslaw; Restel, Magdalena; Samochowiec, Jerzy; Mierzejewski, Pawel

    2017-06-01

    Previous findings revealed high correlations between serum/plasma and saliva levetiracetam concentrations, indicating saliva as an alternative matrix for monitoring levetiracetam therapy. Levetiracetam concentration in the hair, which could reflect long-term drug exposure and patients' compliance, has not been systematically tested, as yet. The aim of this study was to determine the correlation between plasma, saliva, and hair levetiracetam concentrations in 47 patients with epilepsy. Plasma, saliva, and hair levetiracetam concentrations were measured by liquid chromatography-tandem mass spectrometry with positive ionization. Levetiracetam saliva and plasma concentrations were highly correlated (r = 0.93). Plasma concentrations were not influenced by sex, age, and other concomitant antiepileptic drugs. Levetiracetam hair concentrations correlated with plasma concentrations (r = 0.36) but not daily dose (mg/kg). Drug hair concentrations were not influenced by hair color or treatment (dyed). The results tend to indicate that saliva may be a reliable alternative to plasma for monitoring levetiracetam concentrations. Levetiracetam can also be detected in human hair.

  1. Adrenal status assessed by direct radioimmunoassay of cortisol in whole saliva or parotid saliva

    International Nuclear Information System (INIS)

    Walker, R.F.; Riad-Fahmy, D.; Read, G.F.

    1978-01-01

    We describe a direct radioimmunoassay for cortisol in 10-μl volumes of parotid saliva or whole saliva. Binding proteins are absent from these fluids, as demonstrated by the excellent correlation between results for samples assayed directly and by a comparison procedure involving extraction with 1,2-dichloroethane. The direct assay is specific, precise, and had a lower limit of sensitivity of 4 pg per assay tube. Comparison of cortisol concentrations in plasma, parotid saliva, and whole saliva in persons undergoing investigations for assessing adrenal function, including stimulation with cosyntropin (Synachthen) and suppression with dexamethasone, indicated that changes in plasma cortisol concentration were accurately and immediately reflected in saliva from either the parotid-gland or whole saliva. A marked circadian rhythm has also been demonstrated for cortisol in parotid-gland saliva and whole saliva. We had to modify the 1,2-dichloroethane extraction procedure for accurate determination of cortisol in parotid saliva and whole saliva of patients undergoing treatment with metyrapone

  2. SALIVA SEBAGAI UJI SARING OSTEOPOROSIS

    Directory of Open Access Journals (Sweden)

    Niniarty Z. Djamal

    2015-07-01

    Full Text Available Osteoporosis is a metabolic bone disease, and is characterized by low bone mass and microstructure deterioration of the bone, which leads to increased risk of fracture. Biomarker of bone metabolism can be seen as beginning of bone loss and first detection before imbalanced bone turnover comes. Biomarker of bone formation as serum bone alkaline fosfatase, osteocalcin (OC, procollagen type I, and biomarker of bone resorption as urine pyridinoline (Pyd and deoxypyridinoline (Dpd crosslinks, hydroxyprolin. The simultaneous examination of serum OC and urine Pyd or Dpd as a very good screening test for determination of bone imbalanced at the moment of the menopausal or the beginning of the pasca menopausal. Saliva as a potential diagnostic fluid for the assessment of osteoporosis biomarker concentrations. The study found elevated three classic warning signs for osteopororsis os OC, Dpd and 116 in the saliva of sheep without ovaries, which were similar to the levels of signs found in their blood and urine. Expectations, that the test may become available within five years and one day the test may be able to be performed at home like pregnancy test. Osteoporosis biomarker in saliva suggested detected of bone mass density easier. Beside that can be used as a method of early diagnostic and as a monitor therapy that as salinity of the examinations of bone mass on radiology.

  3. 14 CFR 120.21 - Testing for alcohol.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Testing for alcohol. 120.21 Section 120.21... AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Air Traffic Controllers § 120.21 Testing for alcohol. (a) Each air traffic control facility not...

  4. 14 CFR 120.39 - Testing for alcohol.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Testing for alcohol. 120.39 Section 120.39... AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM... Under § 91.147 of This Chapter and Safety-Sensitive Employees § 120.39 Testing for alcohol. (a) Each...

  5. Serum and saliva levels of cathepsin L in patients with acute coronary syndrome.

    Science.gov (United States)

    Mirzaii-Dizgah, Iraj; Riahi, Esmail

    2011-03-01

    Coronary artery disease (CAD) is the major cause of death nearly all over the world, and accurate and rapid diagnosis of CAD is of major medical and economic importance. The aim of this study was to evaluate the serum and saliva levels of cathepsin L in patients with acute coronary syndrome (ACS). In a cross-sectional study, 39 patients with ACS and 28 with controls were recruited to the study, and cathepsin L levels were measured in serum, resting saliva, and stimulated saliva obtained 12 and 24 h after the onset of ACS by ELISA method. Statistical analyses of Fisher's exact test, the Student's t-test or Kruskal-Wallis test were performed. Stimulated saliva cathepsin L levels in patients with ACS 12 hours but not 24 hours after admission showed significant decrease compared with that in control subjects. However, there were no significant differences in serum and unstimulated saliva cathepsin L levels between groups. Serum and saliva levels of cathepsin L remain unchanged in patients with ACS and hence may not be a promising factor in CAD risk assessment. It seems that serum and saliva cathepsin L may not be a good biomarker for CHD. CAD: Coronary artery disease, ACS: Acute coronary syndrome, CHD: Coronary heart disease, EU: Emergency unit, MI: Myocardial infarction. Cathepsin L, Acute coronary syndrome, Resting saliva, Stimulated saliva. How to cite this article: Mirzaii-Dizgah I, Riahi E. Serum and Saliva Levels of Cathepsin L in Patients with Acute Coronary Syndrome. J Contemp Dent Pract 2011;12(2):114-119.

  6. Binding of corroded ions to human saliva.

    Science.gov (United States)

    Mueller, H J

    1985-05-01

    Employing equilibrium dialysis, the binding abilities of Cu, Al, Co and Cr ions from corroded Cu-Al and Co-Cr dental casting alloys towards human saliva and two of its gel chromatographic fractions were determined. Results indicate that both Cu and Co bind to human saliva i.e. 0.045 and 0.027 mg/mg protein, respectively. Besides possessing the largest binding ability, Cu also possessed the largest binding capacity. The saturation of Cu binding was not reached up to the limit of 0.35 mg protein/ml employed in the tests, while Co reached full saturation at about 0.2 mg protein/ml. Chromium showed absolutely no binding to human saliva while Al ions did not pass through the dialysis membranes. Compared to the binding with solutions that were synthetically made up to contain added salivary-type proteins, it is shown that the binding to human saliva is about 1 order of magnitude larger, at least for Cu ions.

  7. Pengaruh Stimulus Pengunyahan dan Pengecapan Terhadap Kecepatan Aliran dan pH Saliva

    Directory of Open Access Journals (Sweden)

    Hj. Edeh Rolette Haroen

    2015-09-01

    Full Text Available The aim of the research were to describe how salivary flow rate and pH vary with time during use of chewing and gustatory stimulation. Fifty young adult subjects collected unstimulated saliva by spitting method, and then collected stimulated saliva by chewing paraffin wax, and a few drops of citric acid are usually placed on the subject’s tongue. The mean of saliva flow rate that unstimulated: 0.50 cc/minute; stimulated saliva by chewing paraffin wax: 1.57 cc/minute, and drops of citric acid stimulation showed that saliva flow rate: 2.98 cc/minute; and pH saliva that unstimulated 6.39; stimulated saliva by chewing paraffin wax 7.2; and stimulated saliva by citric acid: 7.55. Statistical paired t test showed that t lower than t table. The conclusion of the research showed that there were significant influences in the unstimulated salivary flow rates and pH with stimulated saliva elicited by chewing and gustatory stimulation.

  8. Assessment of extracellular dehydration using saliva osmolality.

    Science.gov (United States)

    Ely, Brett R; Cheuvront, Samuel N; Kenefick, Robert W; Spitz, Marissa G; Heavens, Kristen R; Walsh, Neil P; Sawka, Michael N

    2014-01-01

    When substantial solute losses accompany body water an isotonic hypovolemia (extracellular dehydration) results. The potential for using blood or urine to assess extracellular dehydration is generally poor, but saliva is not a simple ultra-filtrate of plasma and the autonomic regulation of salivary gland function suggests the possibility that saliva osmolality (Sosm) may afford detection of extracellular dehydration via the influence of volume-mediated factors. This study aimed to evaluate the assessment of extracellular dehydration using Sosm. In addition, two common saliva collection methods and their effects on Sosm were compared. Blood, urine, and saliva samples were collected in 24 healthy volunteers during paired euhydration and dehydration trials. Furosemide administration and 12 h fluid restriction were used to produce extracellular dehydration. Expectoration and salivette collection methods were compared in a separate group of eight euhydrated volunteers. All comparisons were made using paired t-tests. The diagnostic potential of body fluids was additionally evaluated. Dehydration (3.1 ± 0.5% loss of body mass) decreased PV (-0.49 ± 0.12 L; -15.12 ± 3.94% change), but Sosm changes were marginal ( 0.05). Extracelluar dehydration was not detectable using plasma, urine, or saliva measures. Salivette and expectoration sampling methods produced similar, consistent results for Sosm, suggesting no methodological influence on Sosm.

  9. Saliva Preservative for Diagnostic Purposes

    Science.gov (United States)

    Pierson, Duane L.; Mehta, Satish K.

    2012-01-01

    Saliva is an important body fluid for diagnostic purposes. Glycoproteins, glucose, steroids, DNA, and other molecules of diagnostic value are found in saliva. It is easier to collect as compared to blood or urine. Unfortunately, saliva also contains large numbers of bacteria that can release enzymes, which can degrade proteins and nucleic acids. These degradative enzymes destroy or reduce saliva s diagnostic value. This innovation describes the formulation of a chemical preservative that prevents microbial growth and inactivates the degradative enzymes. This extends the time that saliva can be stored or transported without losing its diagnostic value. Multiple samples of saliva can be collected if needed without causing discomfort to the subject and it does not require any special facilities to handle after it is collected.

  10. Saliva and wound healing.

    Science.gov (United States)

    Brand, Henk S; Ligtenberg, Antoon J M; Veerman, Enno C I

    2014-01-01

    Oral wounds heal faster and with less scar formation than skin wounds. One of the key factors involved is saliva, which promotes wound healing in several ways. Saliva creates a humid environment, thus improving the survival and functioning of inflammatory cells that are crucial for wound healing. In addition, saliva contains several proteins which play a role in the different stages of wound healing. Saliva contains substantial amounts of tissue factor, which dramatically accelerates blood clotting. Subsequently, epidermal growth factor in saliva promotes the proliferation of epithelial cells. Secretory leucocyte protease inhibitor inhibits the tissue-degrading activity of enzymes like elastase and trypsin. Absence of this protease inhibitor delays oral wound healing. Salivary histatins in vitro promote wound closure by enhancing cell spreading and cell migration, but do not stimulate cell proliferation. A synthetic cyclic variant of histatin exhibits a 1,000-fold higher activity than linear histatin, which makes this cyclic variant a promising agent for the development of a new wound healing medication. Conclusively, recognition of the many roles salivary proteins play in wound healing makes saliva a promising source for the development of new drugs involved in tissue regeneration.

  11. Recuperación de veillonellas a partir de saliva Recovery of Veillonella from saliva

    Directory of Open Access Journals (Sweden)

    M.I. Gutiérrez De Ferro

    2005-03-01

    order to determine best saliva recovery, since this sample is generally used to determine the presence and predominance of this bacteria; 2. to detect red fluorescence production on these different culture media as a rapid method for identification. Selective medium for Veillonella, Schaedler agar for anaerobic bacteria with vitamin K, thioglycollate agar, brain heart infusion agar, Brucella agar, trypticase soy agar, and Columbia agar, all of them with and without the addition of vancomycin, and laked blood were used for this study. The tested sample was a saliva pool. Both, Veillonella colonies, and the total number of microorganisms were counted, and expressed as CFU/ml of saliva. The greatest Veillonella recovery in saliva was obtained with the selective medium for Veillonella with vancomycin and laked blood. The production of fluorescence was only observed in this medium.

  12. The diagnostic value of pepsin detection in saliva for gastro-esophageal reflux disease: a preliminary study from China.

    Science.gov (United States)

    Du, Xing; Wang, Feng; Hu, Zhiwei; Wu, Jimin; Wang, Zhonggao; Yan, Chao; Zhang, Chao; Tang, Juan

    2017-10-17

    None of current diagnostic methods has been proven to be a reliable tool for gastro-esophageal reflux disease (GERD). Pepsin in saliva has been proposed as a promising diagnostic biomarker for gastro-esophageal reflux. We aimed to determine the diagnostic value of salivary pepsin detection for GERD. Two hundred and fifty patients with symptoms suggestive of GERD and 35 asymptomatic healthy volunteers provided saliva on morning waking, after lunch and dinner for pepsin determination using the Peptest lateral flow device. All patients underwent 24-h multichannel intraluminal impedance pH (24-h MII-pH) monitoring and upper gastrointestinal endoscopy. Based on 24-h MII-pH and endoscopy study, patients were defined as GERD (abnormal MII-pH results and/or reflux esophagitis) and non-GERD otherwise. Patients with GERD had a higher prevalence of pepsin in saliva and higher pepsin concentration than patients with non-GERD and healthy controls (P < 0.001 for all). The pepsin test had a sensitivity of 73% and a specificity of 88.3% for diagnosing GERD using the optimal cut-off value of 76 ng/mL. Postprandial saliva samples collected when the symptoms occurred had a more powerful ability to identify GERD. Salivary pepsin test had moderate diagnostic value for GERD. It may be a promising tool to replace the use of currently invasive tools with advantages of non-invasive, easy to perform and cost effective. ChiCTR-DDD-16009506 (date of registration: October 20, 2016).

  13. Saliva and dental erosion.

    Science.gov (United States)

    Buzalaf, Marília Afonso Rabelo; Hannas, Angélicas Reis; Kato, Melissa Thiemi

    2012-01-01

    Dental erosion is a multifactorial condition. The consideration of chemical, biological and behavioral factors is fundamental for its prevention and therapy. Among the biological factors, saliva is one of the most important parameters in the protection against erosive wear. This review discusses the role of salivary factors on the development of dental erosion. A search was undertaken on MeDLINe website for papers from 1969 to 2010. The keywords used in the research were "saliva", "acquired pellicle", "salivary flow", "salivary buffering capacity" and "dental erosion". Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. Several characteristics and properties of saliva play an important role in dental erosion. Salivary clearance gradually eliminates the acids through swallowing and saliva presents buffering capacity causing neutralization and buffering of dietary acids. Salivary flow allows dilution of the acids. In addition, saliva is supersaturated with respect to tooth mineral, providing calcium, phosphate and fluoride necessary for remineralization after an erosive challenge. Furthermore, many proteins present in saliva and acquired pellicle play an important role in dental erosion. Saliva is the most important biological factor affecting the progression of dental erosion. Knowledge of its components and properties involved in this protective role can drive the development of preventive measures targeting to enhance its known beneficial effects.

  14. Saliva and dental erosion

    Directory of Open Access Journals (Sweden)

    Marília Afonso Rabelo Buzalaf

    2012-10-01

    Full Text Available Dental erosion is a multifactorial condition. The consideration of chemical, biological and behavioral factors is fundamental for its prevention and therapy. Among the biological factors, saliva is one of the most important parameters in the protection against erosive wear. Objective: This review discusses the role of salivary factors on the development of dental erosion. Material and Methods: A search was undertaken on MeDLINe website for papers from 1969 to 2010. The keywords used in the research were "saliva", "acquired pellicle", "salivary flow", "salivary buffering capacity" and "dental erosion". Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. Results: Several characteristics and properties of saliva play an important role in dental erosion. Salivary clearance gradually eliminates the acids through swallowing and saliva presents buffering capacity causing neutralization and buffering of dietary acids. Salivary flow allows dilution of the acids. In addition, saliva is supersaturated with respect to tooth mineral, providing calcium, phosphate and fluoride necessary for remineralization after an erosive challenge. Furthermore, many proteins present in saliva and acquired pellicle play an important role in dental erosion. Conclusions: Saliva is the most important biological factor affecting the progression of dental erosion. Knowledge of its components and properties involved in this protective role can drive the development of preventive measures targeting to enhance its known beneficial effects.

  15. Saliva Polymerase-Chain-Reaction Assay for Cytomegalovirus Screening in Newborns

    Science.gov (United States)

    Boppana, Suresh B.; Ross, Shannon A.; Shimamura, Masako; Palmer, April L.; Ahmed, Amina; Michaels, Marian G.; Sánchez, Pablo J.; Bernstein, David I.; Tolan, Robert W.; Novak, Zdenek; Chowdhury, Nazma; Britt, William J.; Fowler, Karen B.

    2011-01-01

    BACKGROUND Congenital cytomegalovirus (CMV) infection is an important cause of hearing loss, and most infants at risk for CMV-associated hearing loss are not identified early in life because of failure to test for the infection. The standard assay for newborn CMV screening is rapid culture performed on saliva specimens obtained at birth, but this assay cannot be automated. Two alternatives — real-time polymerase-chain-reaction (PCR)–based testing of a liquid-saliva or dried-saliva specimen obtained at birth — have been developed. METHODS In our prospective, multicenter screening study of newborns, we compared real-time PCR assays of liquid-saliva and dried-saliva specimens with rapid culture of saliva specimens obtained at birth. RESULTS A total of 177 of 34,989 infants (0.5%; 95% confidence interval [CI], 0.4 to 0.6) were positive for CMV, according to at least one of the three methods. Of 17,662 newborns screened with the use of the liquid-saliva PCR assay, 17,569 were negative for CMV, and the remaining 85 infants (0.5%; 95% CI, 0.4 to 0.6) had positive results on both culture and PCR assay. The sensitivity and specificity of the liquid-saliva PCR assay were 100% (95% CI, 95.8 to 100) and 99.9% (95% CI, 99.9 to 100), respectively, and the positive and negative predictive values were 91.4% (95% CI, 83.8 to 96.2) and 100% (95% CI, 99.9 to 100), respectively. Of 17,327 newborns screened by means of the dried-saliva PCR assay, 74 were positive for CMV, whereas 76 (0.4%; 95% CI, 0.3 to 0.5) were found to be CMV-positive on rapid culture. Sensitivity and specificity of the dried-saliva PCR assay were 97.4% (95% CI, 90.8 to 99.7) and 99.9% (95% CI, 99.9 to 100), respectively. The positive and negative predictive values were 90.2% (95% CI, 81.7 to 95.7) and 99.9% (95% CI, 99.9 to 100), respectively. CONCLUSIONS Real-time PCR assays of both liquid- and dried-saliva specimens showed high sensitivity and specificity for detecting CMV infection and should be

  16. A field test of substance use screening devices as part of routine drunk-driving spot detection operating procedures in South Africa.

    Science.gov (United States)

    Matzopoulos, Richard; Lasarow, Avi; Bowman, Brett

    2013-10-01

    This pilot study aimed to test four substance use screening devices developed in Germany under local South African conditions and assess their utility for detecting driving under the influence of drugs (DUID) as part of the standard roadblock operations of local law enforcement agencies. The devices were used to screen a sample of motorists in the Gauteng and Western Cape provinces. The motorists were diverted for screening at roadblocks at the discretion of the law enforcement agencies involved, as per their standard operating procedures. Fieldworkers also administered a questionnaire that described the screening procedure, as well as information about vehicles, demographic information about the motorists and their attitudes to the screening process during testing. Motorists tested positive for breath alcohol in 28% of the 261 cases tested. Oral fluid was screened for drugs as per the standard calibrated cut-offs of all four devices. There were 14 cases where the under-influence drivers tested positive for alcohol and drugs simultaneously, but 14% of the 269 drivers drug-screened tested positive for drugs only. After alcohol, amphetamine, methamphetamine and cocaine were the most common drugs of impairment detected. The results suggest that under normal enforcement procedures only 76% of drivers impaired by alcohol and other drugs would have been detected. In more than 70% of cases the tests were administered within 5 min and this is likely to improve with more regular use. It was clear that the pilot screening process meets global testing standards. Although use of the screening devices alone would not serve as a basis for prosecution and provisions would need to be made for the confirmation of results through laboratory testing, rollout of this screening process would improve operational efficiency in at least two ways. Firstly, the accuracy of the tests will substantially decrease confirmatory test loads. Secondly, laboratory drug testing can be restricted to

  17. Drugs of abuse detection in saliva based on actuated optical method

    Science.gov (United States)

    Shao, Jie; Li, Zhenyu; Jiang, Hong; Wang, Wenlong; Wu, Yixuan

    2014-12-01

    There has been a considerable increase in the abuse of drugs during the past decade. Combing drug use with driving is very dangerous. More than 11% of drivers in a roadside survey tested positive for drugs, while 18% of drivers killed in accidents tested positive for drugs as reported in USA, 2007. Toward developing a rapid drug screening device, we use saliva as the sample, and combining the traditional immunoassays method with optical magnetic technology. There were several methods for magnetic nanoparticles detection, such as magnetic coils, SQUID, microscopic imaging, and Hall sensors. All of these methods were not suitable for our demands. By developing a novel optical scheme, we demonstrate high-sensitivity detection in saliva. Drugs of abuse are detected at sub-nano gram per milliliter levels in less than 120 seconds. Evanescent wave principle has been applied to sensitively monitor the presence of magnetic nanoparticles on the binding surface. Like the total internal reflection fluorescence microscope (TIRFM), evanescent optical field is generated at the plastic/fluid interface, which decays exponentially and penetrates into the fluid by only a sub-wavelength distance. By disturbance total internal reflection with magnetic nanoparticles, the optical intensity would be influenced. We then detected optical output by imaging the sensor surface onto a CCD camera. We tested four drugs tetrahydrocannabinol (THC), methamphetamine (MAMP), ketamine (KET), morphine (OPI), using this technology. 100 ng mL-1 sensitivity was achieved, and obvious evidence showed that this results could be improved in further researches.

  18. 49 CFR 40.271 - How are alcohol testing problems corrected?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false How are alcohol testing problems corrected? 40.271 Section 40.271 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Alcohol Testing § 40.271 How are alcohol testing...

  19. Some Biological Activities of Malaysian Leech Saliva Extract

    OpenAIRE

    Abdualrahman M. Abdualkader; Ahmed Merzouk; Abbas Mohammed Ghawi; and Mohammed Alaama

    2011-01-01

    Leeches were fed on the phagostimulatory solution through parafilm membrane. The satiated leeches were forced to regurgitate the solution by soaking them in an ice-container. The anticoagulant activity was ascertained using thrombin time assay (TT). The result revealed that the saliva concentration which increases TT by 100% (IC100) is 43.205µg/ml plasma. The antimicrobial activity of the saliva was tested against several bacterial spp. (E.coli, P.aeruginosa, B.cereus, Sal.typhi and S...

  20. Disposable collection kit for rapid and reliable collection of saliva.

    Science.gov (United States)

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2)  > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.

  1. 49 CFR 219.701 - Standards for drug and alcohol testing.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Standards for drug and alcohol testing. 219.701... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Drug and Alcohol Testing Procedures § 219.701 Standards for drug and alcohol testing. (a) Drug testing required or authorized by subparts B...

  2. Testing device for pipeline groups and control method for testing device

    International Nuclear Information System (INIS)

    Naito, Shinji; Kajiyama, Shigeru; Takahashi, Fuminobu; Tsuchida, Kenji; Tachibana, Yukio; Shigehiro, Katsuya; Mahara, Yoichi.

    1995-01-01

    The device of the present invention comprises a testing device main body disposed to a rail, a movable mechanism positioning from a reference point, a circumferential direction scanning mechanism, an axial direction scanning mechanism, a posture control mechanism, and a testing probe. Upon testing of pipelines, the detection device main body and auxiliary members are moved from a reference point previously set on a rail for numerical control toward pipelines to be tested in a state where the axial direction scanning mechanism and the testing probe are suspended in the axial direction. The testing is conducted by controlling the position of the testing probe in the axial direction of the pipeline by means of the axial direction scanning mechanism, and scanning the testing probe to the outer circumference of the pipeline along the circumferential track by way of the circumferential direction scanning mechanism. The device can be extremely reduced in the thickness, and can be moved with no interference with pipelines and other obstacles by remote operation even under such undesired condition as the pipelines being crowded, so that non-destructive testing can be conducted accurately. (N.H.)

  3. Passive alcohol sensors tested in 3 states for youth alcohol enforcement

    Science.gov (United States)

    1996-05-01

    Passive alcohol sensors were tested in three states to determine their effectiveness in enforcing zero tolerance or low BAC laws for under 21 age drivers. The passive alcohol sensor was designed to sample the air immediately around the suspect for si...

  4. 49 CFR 40.211 - Who conducts DOT alcohol tests?

    Science.gov (United States)

    2010-10-01

    ...) Screening test technicians (STTs) and breath alcohol technicians (BATs) meeting their respective... conduct only alcohol screening tests, but a BAT can conduct alcohol screening and confirmation tests. (c) As a BAT- or STT-qualified immediate supervisor of a particular employee, you may not act as the STT...

  5. Noninvasive glucose monitoring using saliva nano-biosensor

    Directory of Open Access Journals (Sweden)

    Wenjun Zhang

    2015-06-01

    Full Text Available Millions of people worldwide live with diabetes and several millions die from it each year. A noninvasive, painless method of glucose testing would highly improve compliance and glucose control while reducing complications and overall disease management costs. To provide accurate, low cost, and continuous glucose monitoring, we have developed a unique, disposable saliva nano-biosensor. More than eight clinical trials on real-time noninvasive salivary glucose monitoring were carried out on two healthy individuals (a 2–3 h-period for each trial, including both regular food and standard glucose beverage intake with more than 35 saliva samples obtained. Excellent clinical accuracy was revealed as compared to the UV Spectrophotometer. By measuring subjects’ salivary glucose and blood glucose in parallel, we found the two generated profiles share the same fluctuation trend but the correlation between them is individual dependent. There is a time lag between the peak glucose values from blood and from saliva. However, the correlation between the two glucose values at fasting is constant for each person enabling noninvasive diagnosis of diabetes through saliva instead of blood. Furthermore, a good correlation of glucose levels in saliva and in blood before and 2 h after glucose intake was observed. Glucose monitoring before and 2 h after meals is usually prescribed by doctors for diabetic patients. Thus, this disposable biosensor will be an alternative for real-time salivary glucose tracking at any time.

  6. Total Protein of Whole Saliva as a Biomarker of Anaerobic Threshold

    Science.gov (United States)

    Bortolini, Miguel Junior Sordi; De Agostini, Guilherme Gularte; Reis, Ismair Teodoro; Lamounier, Romeu Paulo Martins Silva; Blumberg, Jeffrey B.; Espindola, Foued Salmen

    2009-01-01

    Saliva provides a convenient and noninvasive matrix for assessing specific physiological parameters, including some biomarkers of exercise. We investigated whether the total protein concentration of whole saliva (TPWS) would reflect the anaerobic threshold during an incremental exercise test. After a warm-up period, 13 nonsmoking men performed a…

  7. Bacterial profiles of saliva in relation to diet, lifestyle factors, and socioeconomic status

    DEFF Research Database (Denmark)

    Belstrøm, Daniel; Holmstrup, Palle; Nielsen, Claus H

    2014-01-01

    BACKGROUND AND OBJECTIVE: The bacterial profile of saliva is composed of bacteria from different oral surfaces. The objective of this study was to determine whether different diet intake, lifestyle, or socioeconomic status is associated with characteristic bacterial saliva profiles. DESIGN: Stimu...... of saliva. CONCLUSIONS: The bacterial profile of saliva seems independent of diet intake, but influenced by smoking and maybe socioeconomic status.......BACKGROUND AND OBJECTIVE: The bacterial profile of saliva is composed of bacteria from different oral surfaces. The objective of this study was to determine whether different diet intake, lifestyle, or socioeconomic status is associated with characteristic bacterial saliva profiles. DESIGN...... presence and levels (mean HOMIM-value) of bacterial probes as endpoints, the influence of diet intake, lifestyle, and socioeconomic status on the bacterial saliva profile was analyzed by Mann-Whitney tests with Benjamini-Hochberg's correction for multiple comparisons and principal component analysis...

  8. Comparison of two chair-side tests for enumeration of Mutans Streptococci in saliva

    DEFF Research Database (Denmark)

    Twetman, Lisa; Twetman, Svante

    2014-01-01

    AIM: To compare the prevalence and levels of salivary Mutans Streptococci (MS) assessed with two commercial chair-side methods based on culture growth or monoclonal antibodies, respectively. MATERIAL AND METHODS: The study group consisted of a convenience sample of 89 adults, 23-72 years of age......, referred to a maxillofacial hospital clinic with a caries history. Stimulated whole saliva samples were collected and the number of MS was assessed with the Dentocult-SM Strip Mutans (DSM) and the Saliva-Check Mutans (SCM). The outcome was compared with conventional anaerobic laboratory cultivation...

  9. Oestrogens in saliva

    International Nuclear Information System (INIS)

    Rothschild, R.S.; Levine, L.S.; Hattingh, J.

    1981-01-01

    Matched plasma and saliva samples were obtained from a non-pregnant and pregnant group (last trimester) of female caucasians. Using a sensitive radioimmunoassay, 17β-oestradiol was measured, and the gingival index system of Loe (1967) was used to assess the gingival condition of each patient. The results showed that 17β-oestradiol could be measured in saliva but that the levels were extremely low and a very sensitive immunoassay was necessary. In the pregnant group, saliva represented 3 per cent of the plasma level. This was not the case in the non-pregnant group, probably because of the constantly changing free: bound plasma ratio. The results are discussed in relation to the fact that oestrogens are known to bind to the oral epithelium [af

  10. Effect of Mobile Phone Usage on Nickel Ions Release and pH of Saliva in Patients Undergoing Fixed Orthodontic Treatment.

    Science.gov (United States)

    Nanjannawar, Lalita Girish; Girme, Tejashree Suresh; Agrawal, Jiwanasha Manish; Agrawal, Manish Suresh; Fulari, Sangamesh Gurunath; Shetti, Shraddha Subhash; Kagi, Vishwal Ajith

    2017-09-01

    Hand held mobile phones are presently the most popular means of communication worldwide and have transformed our lives in many aspects. The widespread use of such devices have resulted in growing concerns regarding harmful effects of radiations emitted by them. This study was designed to evaluate the effects of mobile phone usage on nickel ion release as well as pH of saliva in patients with fixed orthodontic appliances. To assess the level of nickel ions in saliva and pH of saliva in mobile phone users undergoing fixed orthodontic treatment using inductively coupled plasma atomic emission spectrometry. A total of 42 healthy patients with fixed orthodontic appliance in mouth for a duration of six to nine months were selected for the study. They were divided into experimental group (n=21) consisting of mobile phone users and control group (n=21) of non mobile phone users. Saliva samples were collected from both the groups and nickel ion levels were measured using inductively coupled plasma-mass spectroscopy. The pH values were also assessed for both groups using pH meter. Unpaired t-test was used for the data analysis. Statistical analysis revealed that though the pH levels were reduced and the nickel ion levels were higher in the experimental group compared to the control group, the results were non significant. Mobile phone usage may affect the pH of saliva and result in increased release of nickel ions in saliva of patients with fixed orthodontic appliances in the oral cavity.

  11. Bond strength of self-etch adhesives after saliva contamination at different application steps.

    Science.gov (United States)

    Cobanoglu, N; Unlu, N; Ozer, F F; Blatz, M B

    2013-01-01

    This study evaluated and compared the effect of saliva contamination and possible decontamination methods on bond strengths of two self-etching adhesive systems (Clearfil SE Bond [CSE], Optibond Solo Plus SE [OSE]). Flat occlusal dentin surfaces were created on 180 extracted human molar teeth. The two bonding systems and corresponding composite resins (Clearfil AP-X, Kerr Point 4) were bonded to the dentin under six surface conditions (n=15/group): group 1 (control): primer/bonding/composite; group 2: saliva/drying/primer/bonding/composite; group 3: primer/saliva/rinsing/drying/primer/bonding/composite; group 4: primer/saliva/rinsing/drying/bonding/composite; group 5: primer/bonding (cured)/saliva/rinsing/drying/primer/bonding/composite; group 6: primer/bonding (cured)/saliva/removing contaminated layer with a bur/rinsing/drying/primer/bonding/composite. Shear bond strength was tested after specimens were stored in distilled water at 37°C for 24 hours. One-way analysis of variance and Tukey post hoc tests were used for statistical analyses. For CSE, groups 2, 3, and 4 and for OSE, groups 6, 2, and 4 showed significantly lower bond strengths than the control group (pcontamination occurred after light polymerization of the bonding agent, repeating the bonding procedure recovered the bonding capacity of both self-etch adhesives. However, saliva contamination before or after primer application negatively affected their bond strength.

  12. Radiation-induced parotid gland changes in oral cancer patients. Correlation between parotid volume and saliva production

    International Nuclear Information System (INIS)

    Teshima, Keiko; Murakami, Ryuji; Tomitaka, Etsuji

    2010-01-01

    The objective of this study was to evaluate whether saliva production reflects the parotid volume during the course of radiation therapy (RT) in patients with head-and-neck cancer. Twenty patients with advanced oral squamous cell carcinomas, who were treated with preoperative chemo-RT, underwent morphological assessment with CT or MRI and functional assessment with the Saxon test. For the Saxon test, saliva production was measured by weighing a gauze pad before and 2 min after chewing without swallowing; the low-normal value is 2 g. Saliva production and parotid volumes before and 2 weeks after RT were compared with the paired t-test, the Spearman rank correlation test and the Fisher exact test. After 30 Gy irradiation, mean saliva production was decreased from 4.2 to 1.0 g (P 3 (P<0.01); the post-RT: pre-RT parotid volume ratio ranged from 54% to 85% (mean 71%). Although the initial parotid volume was correlated with initial saliva production (r=0.47, P=0.04), no significant correlation was noted after RT (r=0.08, P=0.71), and there were considerable individual variations. The parotid volume ratio was inversely correlated with the saliva-reduction amount (r=-0.79, P<0.01). There was a correlation between decreased parotid gland volume and decreased saliva production in patients with head-and-neck cancer undergoing RT. Parotid volume reduction may predict parotid gland function. (author)

  13. ARSENIC SPECIATION ANALYSIS IN HUMAN SALIVA

    Science.gov (United States)

    Background: Determination of arsenic species in human saliva is potentially useful for biomonitoring of human exposure to arsenic and for studying arsenic metabolism. However, there is no report on the speciation analysis of arsenic in saliva. Methods: Arsenic species in saliva ...

  14. Characterization of the Activity and Stability of Amylase from Saliva and Detergent: Laboratory Practicals for Studying the Activity and Stability of Amylase from Saliva and Various Commercial Detergents

    Science.gov (United States)

    Valls, Cristina; Rojas, Cristina; Pujadas, Gerard; Garcia-Vallve, Santi; Mulero, Miquel

    2012-01-01

    This article presents two integrated laboratory exercises intended to show students the role of [alpha]-amylases (AAMYs) in saliva and detergents. These laboratory practicals are based on the determination of the enzymatic activity of amylase from saliva and different detergents using the Phadebas test (quantitative) and the Lugol test…

  15. The pH changes of artificial saliva after interaction with oral of artificial saliva after interaction with oral micropathogen

    Directory of Open Access Journals (Sweden)

    Basri A. Gani

    2012-12-01

    Full Text Available Backgorund: Saliva contains several protein elements, exocrine proteins and antibodies, such as lactoferrin, sIgA, peroxidase, albumin, polypeptides, and oligopeptides that contribute to the defense of oral mucosa and dental pellicle to prevent infection caused by oral micropathogen, such as Candida albicans, Streptococcus mutans and Aggregatibacter actinomycetemcomitans (A. actinomycetemcomitans. Those micropathogens have a role to change salivary pH as an indicator of oral disease activities. Purpose: This study was aimed to analyze the changes of artificial saliva pH after interaction with S. mutans, C. albicans, and A. Actinomycetemcpmitans. Methods: The materials used in this study consist of S. mutans (ATCC 31987, C. albicans (ATCC 10231, A. actinomycetemcomitans (ATTC 702 358, and artificial saliva. To examine the pH changes of artificial saliva, those three microbiotas were cultured and incubated for 24 hours. Results: The results showed that the interactions of S. mutans, C. albicans, and A. actinomycetemcomitans in the artificial saliva can change the salivary on neutral. There were no significant difference with the control treatment salivary pH 4, 5, 6, 8, and 9 (p>0.05. Similarly, there was also no significant difference when those three microorganism interacted each other in the artificial saliva (p<0.05. Conclusion: It can be concluded that the biological activity of S. mutans, C. albicans, and A. actinomycetemcomitans in artificial saliva can change the salivary pH into neutral. It indicates that those microbiotas mutually supported and cooperated in influencing the biological cycle of the oral cavity with salivary pH as an indicator.Latar belakang: Saliva merupakan cairan eksokrin yang mengandung unsur protein dan antibodi seperti sIgA laktoferin peroksidase, albumin, polipeptida dan oligopeptida yang berperan pada pertahanan mukosa rongga mulut dan gigi guna mencegah infeksi oral mikropatogen seperti C. albicans, S. mutans, dan

  16. Lutzomyia longipalpis saliva or salivary protein LJM19 protects against Leishmania braziliensis and the saliva of its vector, Lutzomyia intermedia.

    Directory of Open Access Journals (Sweden)

    Natalia M Tavares

    Full Text Available BACKGROUND: Leishmania transmission occurs in the presence of insect saliva. Immunity to Phlebotomus papatasi or Lutzomyia longipalpis saliva or salivary components confers protection against an infection by Leishmania in the presence of the homologous saliva. However, immunization with Lutzomyia intermedia saliva did not protect mice against Leishmania braziliensis plus Lu. intermedia saliva. In the present study, we have studied whether the immunization with Lu. longipalpis saliva or a DNA plasmid coding for LJM19 salivary protein would be protective against L. braziliensis infection in the presence of Lu. intermedia saliva, the natural vector for L. braziliensis. METHODOLOGY/PRINCIPAL FINDINGS: Immunization with Lu. longipalpis saliva or with LJM19 DNA plasmid induced a Delayed-Type Hypersensitivity (DTH response against Lu. longipalpis as well as against a Lu. intermedia saliva challenge. Immunized and unimmunized control hamsters were then intradermally infected in the ears with L. braziliensis in the presence of Lu. longipalpis or Lu. intermedia saliva. Animals immunized with Lu. longipalpis saliva exhibited smaller lesion sizes as well as reduced disease burdens both at lesion site and in the draining lymph nodes. These alterations were associated with a significant decrease in the expression levels of IL-10 and TGF-β. Animals immunized with LJM19 DNA plasmid presented similar findings in protection and immune response and additionally increased IFN-γ expression. CONCLUSIONS/SIGNIFICANCE: Immunization with Lu. longipalpis saliva or with a DNA plasmid coding LJM19 salivary protein induced protection in hamsters challenged with L. braziliensis plus Lu. intermedia saliva. These findings point out an important role of immune response against saliva components, suggesting the possibility to develop a vaccine using a single component of Lu. longipalpis saliva to generate protection against different species of Leishmania, even those

  17. Effect of endurance training on dental erosion, caries, and saliva.

    Science.gov (United States)

    Frese, C; Frese, F; Kuhlmann, S; Saure, D; Reljic, D; Staehle, H J; Wolff, D

    2015-06-01

    The aim of this investigation was to give insights into the impact of endurance training on oral health, with regard to tooth erosion, caries, and salivary parameters. The study included 35 triathletes and 35 non-exercising controls. The clinical investigation comprised oral examination, assessment of oral status with special regard to caries and erosion, saliva testing during inactivity, and a self-administered questionnaire about eating, drinking, and oral hygiene behavior. In addition, athletes were asked about their training habits and intake of beverages and sports nutrition. For saliva assessment during exercise, a subsample of n = 15 athletes volunteered in an incremental running field test (IRFT). Athletes showed an increased risk for dental erosion (P = 0.001). No differences were observed with regard to caries prevalence and salivary parameters measured during inactivity between athletes and controls. Among athletes, a significant correlation was found between caries prevalence and the cumulative weekly training time (r = 0.347, P = 0.04). In athletes after IRFT and at maximum workload, saliva flow rates decreased (P = 0.001 stimulated; P = 0.01 unstimulated) and saliva pH increased significantly (P = 0.003). Higher risk for dental erosions, exercise-dependent caries risk, and load-dependent changes in saliva parameters point out the need for risk-adapted preventive dental concepts in the field of sports dentistry. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. 10 CFR 26.101 - Conducting a confirmatory test for alcohol.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Conducting a confirmatory test for alcohol. 26.101 Section... Testing § 26.101 Conducting a confirmatory test for alcohol. (a) The confirmatory test must begin as soon... that meets the requirements of § 26.91(b) and (c) was used for the initial alcohol test, the same EBT...

  19. Hubungan Body Mass Index dengan Laju Aliran Saliva (Studi pada Mahasiswa Fakultas Kedokteran Gigi Universitas Andalas

    Directory of Open Access Journals (Sweden)

    Fildzah Nurul Fajrin

    2015-12-01

    Relationship between Body Mass Index and Saliva Flow Rate (A Study in Faculty of Dentistry, Andalas University. Saliva flow rate is an affecting factor of caries formation. Adequate saliva flow rate can prevent cariess formation process and progression of periodontal disease and oral infection. Nutritional status is known as an influencing factor of saliva flow rate. The parameter of nutritional status is Body Mass Index (BMI. The purpose of this study is to discover the relation between BMI and saliva flow rate in College Students of the Dentistry Faculty Andalas University. This observational study with cross sectional design was conducted to 24 college students of the Dentistry Faculty Andalas University whose ages were 18-25 years old who complied with inclussion and exclussion criteria. BMI was calculated with BMI formula. The saliva flow rate was determined with Sialometry Method of Navazesh 2008 with ”ml/minute” unit. The univariat data analysis was caried out to describe each variable. Normality test Kolmogorov Smirnoff was done to see the normal distribution (p > 0,05. After the distribution was proven to be normal, corelation and regression test was executed to discover the relation between BMI and saliva flow rate. Based on the correlation test result, BMI of college students of the Dentistry Faculty Andalas University is χχ ± SD = 24,6 ± 6,02 kg/m2 and saliva flow rate is χχ ± SD = 0,29 ± 0,1 ml/minute. The relation between BMI and saliva flow rate expresses medium correlation with negative direction ( r = - 0,451. The result of linear regression shows that Saliva Flow Rate = 0,404 - 0,008*(BMI. The coefficient of regression BMI 0.008 shows that increasing 1 unit of BMI will decrease saliva flow rate 0,008 ml/minute. This study concludes that there is correlation between Body Mass Index and saliva flow rate. Obesity group has the lowest saliva flow rate, while the saliva flow rate does not decrease in underweight group.

  20. Protein Biomarkers of Periodontitis in Saliva

    Science.gov (United States)

    Taylor, John J.

    2014-01-01

    Periodontitis is a chronic inflammatory condition of the tissues that surround and support the teeth and is initiated by inappropriate and excessive immune responses to bacteria in subgingival dental plaque leading to loss of the integrity of the periodontium, compromised tooth function, and eventually tooth loss. Periodontitis is an economically important disease as it is time-consuming and expensive to treat. Periodontitis has a worldwide prevalence of 5–15% and the prevalence of severe disease in western populations has increased in recent decades. Furthermore, periodontitis is more common in smokers, in obesity, in people with diabetes, and in heart disease patients although the pathogenic processes underpinning these links are, as yet, poorly understood. Diagnosis and monitoring of periodontitis rely on traditional clinical examinations which are inadequate to predict patient susceptibility, disease activity, and response to treatment. Studies of the immunopathogenesis of periodontitis and analysis of mediators in saliva have allowed the identification of many potentially useful biomarkers. Convenient measurement of these biomarkers using chairside analytical devices could form the basis for diagnostic tests which will aid the clinician and the patient in periodontitis management; this review will summarise this field and will identify the experimental, technical, and clinical issues that remain to be addressed before such tests can be implemented. PMID:24944840

  1. GaN nanostructures-poly(vinyl alcohol) composite based hydrostatic pressure sensor device

    CSIR Research Space (South Africa)

    Linganiso, EC

    2013-12-01

    Full Text Available pressure sensors were fabricated using a GaN/polyvinyl alcohol (PVA) composite film deposited onto an interdigitated electrode and studied by measuring the change in alternating current conductance of the devices at varied applied pressures. Three different...

  2. 10 CFR 26.65 - Pre-access drug and alcohol testing.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Pre-access drug and alcohol testing. 26.65 Section 26.65... § 26.65 Pre-access drug and alcohol testing. (a) Purpose. This section contains pre-access testing... days. If an individual has negative results from drug and alcohol tests that were conducted under the...

  3. Diagnosing feline immunodeficiency virus (FIV) infection in FIV-vaccinated and FIV-unvaccinated cats using saliva.

    Science.gov (United States)

    Westman, Mark E; Malik, Richard; Hall, Evelyn; Norris, Jacqueline M

    2016-06-01

    We recently showed that two immunochromatography point-of-care FIV antibody test kits (Witness FeLV/FIV and Anigen Rapid FIV/FeLV) were able to correctly assign FIV infection status, irrespective of FIV vaccination history, using whole blood as the diagnostic specimen. A third FIV antibody test kit, SNAP FIV/FeLV Combo (an enzyme-linked immunosorbent assay [ELISA]), was unable to differentiate antibodies produced in response to FIV vaccination from those incited by FIV infection. The aim of this study was to determine if saliva is a suitable diagnostic specimen using the same well characterized feline cohort. FIV infection status of these cats had been determined previously using a combination of serology, polymerase chain reaction (PCR) testing and virus isolation. This final assignment was then compared to results obtained using saliva as the diagnostic specimen utilizing the same three point-of-care FIV antibody test kits and commercially available PCR assay (FIV RealPCR). In a population of cats where one third (117/356; 33%) were FIV-vaccinated, both immunochromatography test kits accurately diagnosed FIV infection using saliva via a centrifugation method, irrespective of FIV vaccination history. For FIV diagnosis using saliva, the specificity of Anigen Rapid FIV/FeLV and Witness FeLV/FIV was 100%, while the sensitivity of these kits was 96% and 92% respectively. SNAP FIV/FeLV Combo respectively. SNAP FIV/FeLV Combo had a specificity of 98% and sensitivity of 44%, while FIV RealPCR testing had a specificity of 100% and sensitivity of 72% using saliva. A revised direct method of saliva testing was trialed on a subset of FIV-infected cats (n=14), resulting in 14, 7 and 0 FIV positive results using Anigen Rapid FIV/FeLV, Witness FeLV/FIV and SNAP FIV/FeLV Combo, respectively. These results demonstrate that saliva can be used to diagnose FIV infection, irrespective of FIV vaccination history, using either a centrifugation method (Anigen Rapid FIV/FeLV and Witness

  4. 75 FR 79308 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2011

    Science.gov (United States)

    2010-12-20

    ...-11213, Notice No. 14] Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2011... random testing positive rates were .037 percent for drugs and .014 percent for alcohol. Because the... effective December 20, 2010. FOR FURTHER INFORMATION CONTACT: Lamar Allen, Alcohol and Drug Program Manager...

  5. Device for measuring the alcohol concentration in alcohol/petroleum mixtures. Vorrichtung zur Messung von Alkoholkonzentration in Alkohol-Benzin-Gemischen

    Energy Technology Data Exchange (ETDEWEB)

    Arendt, G

    1983-09-01

    In a device for measuring the alcohol concentration in alcohol/petroleum mixtures, a selective diaphragm for polar and/or non-polar components of the fuel mixture is provided. This diaphragm covers the opening of the tank or the fuel pipe with one surface. It is closed by a chamber on the other side. The chamber has a fresh air inlet and is connected to a subpressure pipe to draw off the gas mixture formed in the chamber. A sensor with connected signal processing is provided near the subpressure pipe in the chamber.

  6. 75 FR 1547 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2010

    Science.gov (United States)

    2010-01-12

    ...-11213, Notice No. 13] RIN 2130-AA81 Alcohol and Drug Testing: Determination of Minimum Random Testing... percent for alcohol. Because the industry-wide random drug testing positive rate has remained below 1.0... effective upon publication. FOR FURTHER INFORMATION CONTACT: Lamar Allen, Alcohol and Drug Program Manager...

  7. Investigation of mixed saliva by optoelectronic methods

    Science.gov (United States)

    Savchenko, Ekaterina; Nepomnyashchaya, Elina; Baranov, Maksim; Velichko, Elena; Aksenov, Evgenii; Bogomaz, Tatyana

    2018-04-01

    At present, saliva and its properties are being actively studied. Human saliva is a unique biological material that has potential in clinical practice. A detailed analysis of the characteristics and properties of saliva is relevant for diagnostic purposes. In this paper, the properties and characteristics of saliva are studied using optoelectronic methods: dynamic light scattering, electrophoretic light scattering and optical microscopy. Mixed saliva from a healthy patient and patient with diabetes mellitus type 2 was used as an object of the study. The dynamics of the behavior of a healthy and patient with diabetes mellitus type 2 is visible according to the results obtained. All three methods confirm hypothesis of structural changes in mixed saliva in the disease of diabetes mellitus type 2.

  8. Quantification of anti-Leishmania antibodies in saliva of dogs.

    Science.gov (United States)

    Cantos-Barreda, Ana; Escribano, Damián; Bernal, Luis J; Cerón, José J; Martínez-Subiela, Silvia

    2017-08-15

    Detection of serum anti-Leishmania antibodies by quantitative or qualitative techniques has been the most used method to diagnose Canine Leishmaniosis (CanL). Nevertheless, saliva may represent an alternative to blood because it is easy to collect, painless and non-invasive in comparison with serum. In this study, two time-resolved immunofluorometric assays (TR-IFMAs) for quantification of anti-Leishmania IgG2 and IgA antibodies in saliva were developed and validated and their ability to distinguish Leishmania-seronegative from seropositive dogs was evaluated. The analytical study was performed by evaluation of assay precision, sensitivity and accuracy. In addition, serum from 48 dogs (21 Leishmania-seropositive and 27 Leishmania-seronegative) were analyzed by TR-IFMAs. The assays were precise, with an intra- and inter-assay coefficients of variation lower than 11%, and showed high level of accuracy, as determined by linearity under dilution (R 2 =0.99) and recovery tests (>88.60%). Anti-Leishmania IgG2 antibodies in saliva were significantly higher in the seropositive group compared with the seronegative (pLeishmania IgA antibodies between both groups were observed. Furthermore, TR-IFMA for quantification of anti-Leishmania IgG2 antibodies in saliva showed higher differences between seropositive and seronegative dogs than the commercial assay used in serum. In conclusion, TR-IFMAs developed may be used to quantify anti-Leishmania IgG2 and IgA antibodies in canine saliva with an adequate precision, analytical sensitivity and accuracy. Quantification of anti-Leishmania IgG2 antibodies in saliva could be potentially used to evaluate the humoral response in CanL. However, IgA in saliva seemed not to have diagnostic value for this disease. For future studies, it would be desirable to evaluate the ability of the IgG2 assay to detect dogs with subclinical disease or with low antibody titers in serum and also to study the antibodies behaviour in saliva during the

  9. Enhancement of Cellulose Degradation by Cattle Saliva

    Science.gov (United States)

    Seki, Yasutaka; Kikuchi, Yukiko; Kimura, Yoshihiro; Yoshimoto, Ryo; Takahashi, Masatoshi; Aburai, Kenichi; Kanai, Yoshihiro; Ruike, Tatsushi; Iwabata, Kazuki; Sugawara, Fumio; Sakai, Hideki; Abe, Masahiko; Sakaguchi, Kengo

    2015-01-01

    Saccharification of cellulose is a promising technique for producing alternative source of energy. However, the efficiency of conversion of cellulose into soluble sugar using any currently available methodology is too low for industrial application. Many additives, such as surfactants, have been shown to enhance the efficiency of cellulose-to-sugar conversion. In this study, we have examined first whether cattle saliva, as an additive, would enhance the cellulase-catalyzed hydrolysis of cellulose, and subsequently elucidated the mechanism by which cattle saliva enhanced this conversion. Although cattle saliva, by itself, did not degrade cellulose, it enhanced the cellulase-catalyzed degradation of cellulose. Thus, the amount of reducing sugar produced increased approximately 2.9-fold by the addition of cattle saliva. We also found that non-enzymatic proteins, which were present in cattle saliva, were responsible for causing the enhancement effect. Third, the mechanism of cattle saliva mediated enhancement of cellulase activity was probably similar to that of the canonical surfactants. Cattle saliva is available in large amounts easily and cheaply, and it can be used without further purification. Thus, cattle saliva could be a promising additive for efficient saccharification of cellulose on an industrial scale. PMID:26402242

  10. Shear bond strength of orthodontic brackets and disinclusion buttons: effect of water and saliva contamination.

    Science.gov (United States)

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea

    2013-01-01

    The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  11. Detection of Helicobacter pylori urease antigen in saliva in patients with different gastric H. pylori status.

    Science.gov (United States)

    El Khadir, Mounia; Alaoui Boukhris, Samia; Benajah, Dafr-Allah; El Rhazi, Karima; Ibrahimi, Sidi Adil; El Abkari, Mohamed; Harmouch, Taoufiq; Nejjari, Chakib; Mahmoud, Mustapha; Benlemlih, Mohamed; Bennani, Bahia

    2016-07-01

    Finding a simple, accurate, and noninvasive diagnosis method is a substantial challenge for the detection of Helicobacter pylori. The aim of the present study was to compare the presence of H. pylori urease antigen in saliva with the presence of this bacterium in gastric mucosa. Saliva samples and gastric biopsies were taken from 153 consenting Moroccan patients. Saliva samples were analyzed using an immunochromatographic test for urease antigen H. pylori detection. Thereafter, the gastric biopsies were analyzed by histology and polymerase chain reaction (PCR) to detect this bacterium. From a total of 153 recruited Moroccan patients, H. pylori was detected in 28 (18.30%), 87 (57.24%), and 69 (45.10%) cases by saliva test, histology, and PCR, respectively. A significant association was observed between the presence of H. pylori antigen in saliva and age. However, no association was found with sex, H. pylori virulence factors, gastric disease outcome, and density of the bacterium on the gastric mucosa. Considering that only 90 patients presented concordant results on H. pylori diagnosis (positive or negative) by both histology and PCR, the immunochromatographic test showed very low sensitivity (29.79%) and high specificity (90.70%). Of these two tests, the positive and negative predictive values were 77.78% and 54.17%, respectively. The accuracy of the test for salivary detection of urease antigen H. pylori was 58.89%. This study demonstrated a low detection rate of H. pylori antigens in saliva compared with the presence of this bacterium in gastric mucosa, suggesting that saliva cannot be used as a suitable sample for the diagnosis of H. pylori in our study population. Copyright © 2016. Published by Elsevier Taiwan LLC.

  12. Alcohol calibration of tests measuring skills related to car driving.

    Science.gov (United States)

    Jongen, Stefan; Vuurman, Eric; Ramaekers, Jan; Vermeeren, Annemiek

    2014-06-01

    Medication and illicit drugs can have detrimental side effects which impair driving performance. A drug's impairing potential should be determined by well-validated, reliable, and sensitive tests and ideally be calibrated by benchmark drugs and doses. To date, no consensus has been reached on the issue of which psychometric tests are best suited for initial screening of a drug's driving impairment potential. The aim of this alcohol calibration study is to determine which performance tests are useful to measure drug-induced impairment. The effects of alcohol are used to compare the psychometric quality between tests and as benchmark to quantify performance changes in each test associated with potentially impairing drug effects. Twenty-four healthy volunteers participated in a double-blind, four-way crossover study. Treatments were placebo and three different doses of alcohol leading to blood alcohol concentrations (BACs) of 0.2, 0.5, and 0.8 g/L. Main effects of alcohol were found in most tests. Compared with placebo, performance in the Divided Attention Test (DAT) was significantly impaired after all alcohol doses and performance in the Psychomotor Vigilance Test (PVT) and the Balance Test was impaired with a BAC of 0.5 and 0.8 g/L. The largest effect sizes were found on postural balance with eyes open and mean reaction time in the divided attention and the psychomotor vigilance test. The preferable tests for initial screening are the DAT and the PVT, as these tests were most sensitive to the impairing effects of alcohol and being considerably valid in assessing potential driving impairment.

  13. Naked-Eye Detection of Glucose in Saliva with Bienzymatic Paper-Based Sensor

    Directory of Open Access Journals (Sweden)

    Luis A. Santana-Jiménez

    2018-04-01

    Full Text Available The high incidence of Diabetes Mellitus in low-income regions has promoted the development of low-cost alternatives to replace blood-based procedures. In this work, we present a bienzymatic paper-based sensor suitable for the naked-eye detection of glucose in saliva samples. The sensor was obtained by a stamping procedure and modified with chitosan to improve the colorimetric readout. The bienzymatic reaction of GOx-HRP coupled with 2,4,6-tribromo-3-hydroxy benzoic acid was applied for the detection of glucose within a range from 0 to 180 mgdL−1 in buffer and artificial saliva solutions. The visual readout was perceived by the naked eye and registered with an office scanner to evaluate the analytical performance. The results showed a limit of detection of 0.37 mgdL−1 (S/N = 3 with an R.S.D. of 1.69% and a linear range from 1 to 22.5 mgdL−1 with an R2 of 0.99235. The analysis of human saliva samples was performed without pre-processing, achieving recoveries from 92 to 114%. The naked-eye detection was evaluated under two different light settings, showing average recoveries of 108.58 and 90.65% for standard and low illumination. The proposed device showed potential for easy-to-use, sensitive, low-cost, fast, and device-free detection of salivary glucose suitable for untrained personnel operation and limited facilities.

  14. Validation of the Cross-Cultural Alcoholism Screening Test (CCAST).

    Science.gov (United States)

    Gorenc, K D; Peredo, S; Pacurucu, S; Llanos, R; Vincente, B; López, R; Abreu, L F; Paez, E

    1999-01-01

    When screening instruments that are used in the assessment and diagnosis of alcoholism of individuals from different ethnicities, some cultural variables based on norms and societal acceptance of drinking behavior can play an important role in determining the outcome. The accepted diagnostic criteria of current market testing are based on Western standards. In this study, the Munich Alcoholism Test (31 items) was the base instrument applied to subjects from several Hispanic-American countries (Bolivia, Chile, Ecuador, Mexico, and Peru). After the sample was submitted to several statistical procedures, these 31 items were reduced to a culture-free, 31-item test named the Cross-Cultural Alcohol Screening Test (CCAST). The results of this Hispanic-American sample (n = 2,107) empirically demonstrated that CCAST measures alcoholism with an adequate degree of accuracy when compared to other available cross-cultural tests. CCAST is useful in the diagnosis of alcoholism in Spanish-speaking immigrants living in countries where English is spoken. CCAST can be used in general hospitals, psychiatric wards, emergency services and police stations. The test can be useful for other professionals, such as psychological consultants, researchers, and those conducting expertise appraisal.

  15. Correlation between factors associated with the removable partial dentures use and Candida spp. in saliva.

    Science.gov (United States)

    Gusmão, João Milton Rocha; Ferreira dos Santos, Silvana Soleo; Neisser, Maximiliano Piero; Jorge, Antônio Olavo Cardoso; Faria, Ms Ivan

    2011-12-01

    To correlate the presence and number of Candida spp. in the saliva of wearers of removable partial dentures retained with precision attachments with the proportion of metal/acrylic resin present in the dentures. Saliva samples from 40 removable partial denture wearers (test) and one paired sample of individuals, non-wearers of any type of removable denture (control) were collected, seeded, and the colony forming units of Candida counted and identified. The metal/acrylic resin proportion of each denture was quantified, using silicone plates pressed over each denture. Candida spp. was found in the saliva of 80% of the individuals in the test group and 65% of the control, with C. albicans being the most prevalent species. The test group presented with the highest number of colony forming units of Candida per ml of saliva, and there was weak correlation between this number and the metal and resin area of the denture (Pearson's coefficient of correlation). Greater prevalence and a higher number of colony forming units of Candida per ml of saliva occurred in removable partial denture wearers (p = 0.04) with a weak positive correlation between the metal and resin area and the number of colony forming units of Candida per ml of saliva. However, this correlation was more significant for the area of resin. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  16. Pilot study of risk behaviour, voluntary HIV counselling and HIV antibody testing from saliva among inmates of prisons in Slovakia.

    Science.gov (United States)

    Staneková, D; Ondrejka, D; Habeková, M; Wimmerová, S; Kucerková, S

    2001-05-01

    To implement a pilot study of risk behaviour and HIV infection using HIV antibody testing from saliva to improve the situation as regards HIV/AIDS infection in prison institutions in the Slovak Republic. The study comprised adult and juvenile males of grade one correction categories and prisoners from the prison for juveniles in Martin, as well as females prisoners in Nitra. Preventive activities were implemented in May 1998 in the form of discussions concerning topics related to HIV/AIDS infection. Saliva was collected for the presence of HIV antibodies and a questionnaire regarding sexual practice was completed. 32 persons [8 adult males (25%), 6 juvenile males (18.7%) and 18 females (56%)] were voluntarily tested for the presence of HIV antibodies in saliva. Nobody was HIV-positive. 75 persons (20 adult males, 30 juvenile males and 25 females) were involved in the study of risk behaviour. 40.8% participants had primary education, 28.2% secondary education, 2.8% were students of universities and 28.2% were apprenticies. 60% inmates (mostly females) were religious. Juvenile males reported the highest number of partners while females the smallest (p prison while 19%, 5.6% and 8.3% in the prison, respectively. Paid sexual services were offered by 9.1% females, 15.8% adult males and 25% juvenile males. Outside prison adult and juvenile males used non-sterile used syringes as well as tattooing more often than females (p prisoners.

  17. 76 FR 80781 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2012

    Science.gov (United States)

    2011-12-27

    ...-11213, Notice No. 15] RIN 2130-AA81 Alcohol and Drug Testing: Determination of Minimum Random Testing...: Lamar Allen, Alcohol and Drug Program Manager, Office of Safety Enforcement, Mail Stop 25, Federal... Kathy Schnakenberg, FRA Alcohol/Drug Program Specialist, (telephone (719) 633-8955). Issued in...

  18. SALIVA AS A DIAGNOSTIC FLUID

    Directory of Open Access Journals (Sweden)

    Pezelj-Ribarić Sonja

    2015-12-01

    Full Text Available Saliva is a readily available oral fluid with many functions, from digestion, maintenance of oral tissues' integrity, to caries prevention. Changes regarding its secretion may be divided into qualitative and quantitative: both of them are a consequence of certain conditions/diseases (e.g. internal factors or nutrients/drugs ingested (e.g. external factors. During the last 15 years, technological advances gave a significant momentum to utilization of saliva as a diagnostic tool. Analysis of saliva, just like the blood analysis, has two main objectives: to identify the subjects suffering from a certain disorder, and to follow the development and progress of therapy. This paper provides an overview of possibilities for the use of saliva for diagnostic purposes and gives specific examples of some clinical investigations, with the final aim to stimulate the use of this noninvasive means for the health care promotion.

  19. The Effect of Alcohol-Based Hand Sanitizer Vapors on Evidential Breath Alcohol Test Results.

    Science.gov (United States)

    Strawsine, Ellen; Lutmer, Brian

    2017-11-16

    This study was undertaken to determine if the application of alcohol-based hand sanitizers (ABHSs) to the hands of a breath test operator will affect the results obtained on evidential breath alcohol instruments (EBTs). This study obtained breath samples on three different EBTs immediately after application of either gel or foam ABHS to the operator's hands. A small, but significant, number of initial analyses (13 of 130, 10%) resulted in positive breath alcohol concentrations, while 41 samples (31.5%) resulted in a status code. These status codes were caused by ethanol vapors either in the room air or their inhalation by the subject, thereby causing a mouth alcohol effect. Replicate subject samples did not yield any consecutive positive numeric results. As ABHS application can cause a transitory mouth alcohol effect via inhalation of ABHS vapors, EBT operators should forego the use of ABHS in the 15 min preceding subject testing. © 2017 American Academy of Forensic Sciences.

  20. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    Science.gov (United States)

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola

    2013-01-01

    Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons. PMID:23762825

  1. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    Directory of Open Access Journals (Sweden)

    Maria Francesca Sfondrini

    2013-01-01

    Full Text Available Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a dry, (b water contamination, and (c saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values and Chi squared test (ARI Scores. Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  2. Influence of Alcohol and Alcohol-free Mouthrinses on Force Degradation of Different Types of Space Closure Auxiliaries used in Sliding Mechanics

    OpenAIRE

    Vivek Mahajan; Anil Singla; Anurag Negi; Harupinder Singh Jaj; Vikrant Bhandari

    2014-01-01

    Introduction: The objective of the study was to evaluate the percentage of force degradation of elastomeric chains, NiTi closed coil spring and stainless steel closed coil spring at different time intervals in different media. Materials and methods: Three types of space closing auxiliaries, such as elastomeric chains, NiTi closed coil springs and stainless steel coil springs immersed in artificial saliva, alcohol-free mouthrinse (Colgate plax) and alcohol-containing mouthrinse (Listerine...

  3. 77 FR 10666 - Pipeline Safety: Post Accident Drug and Alcohol Testing

    Science.gov (United States)

    2012-02-23

    ... 199 [Docket No. PHMSA-2011-0335] Pipeline Safety: Post Accident Drug and Alcohol Testing AGENCY... operators of Liquefied Natural Gas (LNG) facilities to conduct post- accident drug and alcohol tests of..., operators must drug and alcohol test each covered employee whose performance either contributed to the...

  4. 78 FR 78275 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2014

    Science.gov (United States)

    2013-12-26

    ...-11213, Notice No. 17] Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2014... December 26, 2013. FOR FURTHER INFORMATION CONTACT: Jerry Powers, FRA Drug and Alcohol Program Manager, W38...-493-6313); or Sam Noe, FRA Drug and Alcohol Program Specialist, (telephone 615-719- 2951). Issued in...

  5. Virtual Turbine Engine Test Bench Using MGET Test Device

    Science.gov (United States)

    Kho, Seonghee; Kong, Changduk; Ki, Jayoung

    2015-05-01

    Test device using virtual engine simulator can help reduce the number of engine tests through tests similar to the actual engine tests and repeat the test under the same condition, and thus reduce the engine maintenance and operating costs [1]. Also, as it is possible to easily implement extreme conditions in which it is hard to conduct actual tests, it can prevent engine damages that may happen during the actual engine test under such conditions. In this study, an upgraded MGET test device was developed that can conduct both real and virtual engine test by applying real-time engine model to the existing MGET test device that was developed and has been sold by the Company. This newly developed multi-purpose MGET test device is expected to be used for various educational and research purposes.

  6. Drug use among drivers who drank on alcohol outlets from Porto Alegre, Brazil.

    Science.gov (United States)

    De Boni, Raquel B; Bastos, Francisco Inacio; de Vasconcellos, Mauricio; Oliveira, Fernanda; Limberger, Renata P; Pechansky, Flavio

    2014-01-01

    Driving under the influence of multiple substances is a public health concern, but there is little epidemiological data about their combined use and putative impact on driving in low and middle-income countries where traffic crashes have been clustering in recent years. The aim of this study is to estimate the prevalence of alcohol and drug use - as well as their associated factors - among drivers in the context of alcohol outlets (AOs). A probability three-stage sample survey was conducted in Porto Alegre, Brazil. Individuals who were leaving AO were screened, with the selection of 683 drivers who met the inclusion criteria. Drivers answered a structured interview, were breathalyzed, and had their saliva collected for drug screening. Prevalences were assessed using domain estimation and logistic regression models assessed covariates associated with substance use. Benzodiazepines 3.9% (SE 2.13) and cocaine 3.8% (SE 1.3) were the most frequently detected drugs in saliva. Among drivers who were going to drive, 11% had at least one drug identified by the saliva drug screening, 0.4% two, and 0.1% three drugs in addition to alcohol. In multivariable analyses, having a blood alcohol concentration (BAC)>0.06% was found to be associated with a 3.64 times (CI 95% 1.79-7.39) higher chance of drug detection, compared with interviewees with lower BACs. To drive under the influence of multiple substances is likely to be found in this setting, highlighting an association between harmful patterns of consume of alcohol and the misuse of other substances. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Comparative evaluation of qigong on various parameters of saliva

    Directory of Open Access Journals (Sweden)

    Bayat Movahed S.

    2007-05-01

    Full Text Available Background and Aim: Qigong is a type of Chinese psychosomatic exercise that integrates meditation, slow physical movements, and breathing. Numerous physical and mental benefits have been classically ascribed to qigong. On the other hand, unstimulated saliva is thought to play an important role in oral immunity, enamel stability and moisturizing the oral mucous membrane. Impaired salivary secretion leads to dental caries, mucosal deterioration and mouth dryness. The aim of the present study was to analyze the effect of a qigong program on various parameters of saliva such as quantity of unstimulated saliva, pH and SIgA. Materials and Methods: Twenty three subjects participated in this clinical trial study. The experimental subjects underwent a qigong training program, conducted by a qualified instructor. The program consisted of half an hour daily practice for 6 months (spring and winter. Saliva was collected in two periods: once during the spring before the experiment commencement and the second, in the following spring. During each period saliva collection was done on tuesday of each week. pH and quantity of salvia measurements were taken simultaneously. SIgA measurements were also taken based on the values obtained in the last phase of the experiment at the end of each spring. The results were analyzed using paired sample T test, one way repeated measure and Bon Ferroni multiple comparison. P<0.05 was the level of significance. Results: Based on our findings, the change in the amount of unstimulated salvia as well as SIgA was statistically significant (P<0.001; however, there was no significant difference in pH values before and after experiment. Conclusion: These findings demonstrate that after 6 months of practicing qigong, significant changes in amount of unstimulated saliva and SIgA occurred in participants. The authors suggest that qigong may be a beneficial adjunctive treatment that enhances amount of unstimulated saliva and SIgA.

  8. Frequency of enterococcus faecalis in saliva and root canals with treatment failure

    International Nuclear Information System (INIS)

    Khan, I.; Shan, T.; Manzoor, M.A.

    2015-01-01

    To compare the frequency of E. faecalis in the saliva and root canals of teeth associated with apical periodontitis due to endodontic treatment failure in the same patient. Study Design: Cross-sectional comparative study. Place and Duration of Study: Samples were collected from Operative Dentistry Department, AFID, while laboratory processing was done at AFIP, Rawalpindi. Study duration was one year. Patients and Methods: Fifty patients, both males and females with failed endodontic treatment were selected. Saliva and root canal samples were collected from each patient, inoculated on MacKonkey agar plate and incubated at 35-37 degree C for 48 hrs. E. faecalis colonies were identified by colony morphology, gramstain, catalase, bile asculin test, arabinose fermentation and growth in 6% NaCl nutrient broth. Results: The frequency of E. faecalis in saliva was 34% and in root canal it was 58%. Frequency between the presence of E. faecalis in root canals and saliva was found to be statistically different (p = 0.001). Conclusion: The presence of E. faecalis in root canal was not associated with their presence in saliva. (author)

  9. Frequency of enterococcus faecalis in saliva and root canals with treatment failure

    International Nuclear Information System (INIS)

    Shan, T.; Manzoor, M.A.; Hussain, W.

    2014-01-01

    To compare the frequency of E.faecalis in the saliva and root canals of teeth associated with apical periodontitis due to endodontic treatment failure Study. Design: Cross-sectional comparative. Place and Duration of Study: Samples were collected from Operative Dentistry department, AFID, while laboratory processing was done at AFIP, Rawalpindi. Duration of this study was one year. Patients and Method: Fifty patients, both males and females with failed endodontic treatment were selected. Saliva and root canal samples were collected from each patient, inoculated on MacKonkey agar plate and incubated at 35-370 C for 48 hours. E.faecalis colonies were identified by colony morphology, Gram stain, catalase, bile asculin test, arabinose fermentation and growth in 6% NaCl nutrient broth. Results: The frequency of E.faecalis in saliva was 34% and 58% in root canal samples. Frequency of the presence of E.faecalis in root canals and saliva was found to be statistically different (p=0.000). Conclusion: The presence of E.faecalis in root canal was not associated with their presence in saliva. (author)

  10. 49 CFR 40.13 - How do DOT drug and alcohol tests relate to non-DOT tests?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false How do DOT drug and alcohol tests relate to non... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Employer Responsibilities § 40.13 How do DOT drug and... non-DOT drug and alcohol testing programs. This prohibition includes the use of the DOT forms with...

  11. Detection of Zika virus using reverse-transcription LAMP coupled with reverse dot blot analysis in saliva.

    Directory of Open Access Journals (Sweden)

    Maite Sabalza

    Full Text Available In recent years, there have been increasing numbers of infectious disease outbreaks that spread rapidly to population centers resulting from global travel, population vulnerabilities, environmental factors, and ecological disasters such as floods and earthquakes. Some examples of the recent outbreaks are the Ebola epidemic in West Africa, Middle East respiratory syndrome coronavirus (MERS-Co in the Middle East, and the Zika outbreak through the Americas. We have created a generic protocol for detection of pathogen RNA and/or DNA using loop-mediated isothermal amplification (LAMP and reverse dot-blot for detection (RDB and processed automatically in a microfluidic device. In particular, we describe how a microfluidic assay to detect HIV viral RNA was converted to detect Zika virus (ZIKV RNA. We first optimized the RT-LAMP assay to detect ZIKV RNA using a benchtop isothermal amplification device. Then we implemented the assay in a microfluidic device that will allow analyzing 24 samples simultaneously and automatically from sample introduction to detection by RDB technique. Preliminary data using saliva samples spiked with ZIKV showed that our diagnostic system detects ZIKV RNA in saliva. These results will be validated in further experiments with well-characterized ZIKV human specimens of saliva. The described strategy and methodology to convert the HIV diagnostic assay and platform to a ZIKV RNA detection assay provides a model that can be readily utilized for detection of the next emerging or re-emerging infectious disease.

  12. White Light Generation in Human Saliva

    Science.gov (United States)

    Santhosh, C.; Dharmadhikari, A. K.; Dharmadhikari, J. A.; Alti, K.; Mathur, D.

    2011-07-01

    Interaction of intense, femto-second pulses of infrared light (800 nm) with water generates white light supercontinuum due to nonlinear optical effects. This supercontinuum was found to be suppressed by the addition of alpha amylase, a major protein in the human saliva. We have studied the suppression of supper continuum by human saliva, collected from healthy subjects with and without smoking habits. Suppression of the blue-sided components was observed significantly in non-smokers saliva than chain smokers.

  13. Effectiveness of transcutaneous electrical nerve stimulation on saliva production in post-radiated oral cancer patients

    OpenAIRE

    Sakshi Ojha; Thimmarasa V Bhovi; Prashant P Jaju; Manas Gupta; Neha Singh; Kriti Shrivastava

    2016-01-01

    Aims and Objectives: To determine the effectiveness of transcutaneous electrical nerve stimulation (TENS) in stimulating salivary flow in post-radiated oral cancer patients, and to compare the salivary flow rate between unstimulated saliva and saliva stimulated with TENS in post-radiated oral cancer patients. Materials and Methods: In 30 patients who underwent radiotherapy for oral cancer, unstimulated saliva was collected every minute for 5 min in a graduated test tube. The TENS unit was act...

  14. Measuring DHEA-S in saliva: time of day differences and positive correlations between two different types of collection methods

    Directory of Open Access Journals (Sweden)

    Klein Laura C

    2010-07-01

    Full Text Available Abstract Background The anabolic steroid, dehydroepiandosterone sulfate (DHEA-S, is secreted from the adrenal cortex. It plays a significant role in the body as a precursor to sex steroids as well as a lesser known role in the hypothalamic pituitary adrenal axis (HPA response to stress. DHEA-S can be measured reliably in saliva, making saliva collection a valuable tool for health research because it minimizes the need for invasive sampling procedures (e.g., blood draws. Typical saliva collection methods include the use of plain cotton swab collection devices (e.g., Salivette® or passive drool. There has been some speculation that the plain saliva cotton collection device may interfere with determination of DHEA-S by enzyme immunoassay (EIA bringing this saliva collection method into question. Because of the increasing popularity of salivary biomarker research, we sought to determine whether the cotton swab interferes with DHEA-S determination through EIA techniques. Findings Fifty-six healthy young adult men and women aged 18-30 years came to the lab in the morning (0800 hrs; 14 men, 14 women or late afternoon (1600 hrs; 14 men, 14 women and provided saliva samples via cotton Salivette and passive drool. Passive drool collection was taken first to minimize particle cross contamination from the cotton swab. Samples were assayed for DHEA-S in duplicate using a commercially available kit (DSL, Inc., Webster, TX. DHEA-S levels collected via Salivette and passive drool were positively correlated (r = + 0.83, p Conclusions Results suggest that DHEA-S can be measured accurately using passive drool or cotton Salivette collection methods. Results also suggest that DHEA-S levels change across the day and that future studies need to take this time of day difference into account when measuring DHEA-S.

  15. Blood-alcohol proficiency test program

    Science.gov (United States)

    1975-01-01

    A preliminary survey has been performed to ascertain the validity of the blood alcohol analysis performed by a number of laboratories on a voluntary basis. Values of accuracy and precision of the tests are presented. /Abstract from report summary pag...

  16. A visual test based on a freeware software for quantifying and displaying night-vision disturbances: study in subjects after alcohol consumption.

    Science.gov (United States)

    Castro, José J; Ortiz, Carolina; Pozo, Antonio M; Anera, Rosario G; Soler, Margarita

    2014-05-07

    In this work, we propose the Halo test, a simple visual test based on a freeware software for quantifying and displaying night-vision disturbances perceived by subjects under different experimental conditions, more precisely studying the influence of the alcohol consumption on visual function. In the Halo test, viewed on a monitor, the subject's task consists of detecting luminous peripheral stimuli around a central high-luminance stimulus over a dark background. The test, performed by subjects before and after consuming alcoholic drinks, which deteriorate visual performance, evaluates the influence that alcohol consumption exerts on the visual-discrimination capacity under low illumination conditions. Measurements were made monocularly and binocularly. Pupil size was also measured in both conditions (pre/post). Additionally, we used a double-pass device to measure objectively the optical-quality of the eye and corroborate the results from the Halo test. We found a significant deterioration of the discrimination capacity after alcohol consumption, indicating that the higher the breath-alcohol content, the greater the deterioration of the visual-discrimination capacity. After alcohol intake, the graphical results showed a greater area of undetected peripheral stimuli around the central high-luminance stimulus. An enlargement of the pupil was also observed and the optical quality of the eye was deteriorated after alcohol consumption. A greater influence of halos and other night-vision disturbances were reported with the Halo test after alcohol consumption. The Halo freeware software constitutes a positive contribution for evaluating nighttime visual performance in clinical applications, such as reported here, but also in patients after refractive surgery (where halos are present) or for monitoring (time course) some ocular pathologies under pharmacological treatment.

  17. Characterisation of human saliva as a platform for oral dissolution medium development.

    Science.gov (United States)

    Gittings, Sally; Turnbull, Neil; Henry, Brian; Roberts, Clive J; Gershkovich, Pavel

    2015-04-01

    Human saliva is a biological fluid of great importance in the field of dissolution testing. However, until now, no consensus has been reached on its key characteristics relevant to dissolution testing. As a result, it is difficult to select or develop an in vitro dissolution medium to best represent human saliva. In this study, the pH, buffer capacity, surface tension, viscosity and flow rate of both unstimulated (US) and stimulated (SS) human saliva were investigated in order to provide a platform of reference for future dissolution studies using simulated salivary fluids. Age and gender related differences in a sample size of 30 participants for each parameter were investigated. Significant differences were established between US and SS for all characteristics except surface tension. Therefore, the requirement for using two simulated salivary fluids should be considered when developing an oral dissolution model. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Drug and alcohol testing results 2009 annual report

    Science.gov (United States)

    2013-11-01

    This is the 15th annual report of the results of the Federal Transit Administrations (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2009, the requirements of the overall drug and alcohol...

  19. Drug and alcohol testing results 2007 annual report

    Science.gov (United States)

    2009-05-01

    This is the 13th annual report of the results of the Federal Transit Administrations (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2007, the requirements of the overall drug and alcohol...

  20. Drug and alcohol testing results 2006 annual report.

    Science.gov (United States)

    2008-08-01

    This is the 12th annual report of the results of the Federal Transit Administration's (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2006, the requirements of the overall drug and alcohol t...

  1. 77 FR 75896 - Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2013

    Science.gov (United States)

    2012-12-26

    ...-11213, Notice No. 16] Alcohol and Drug Testing: Determination of Minimum Random Testing Rates for 2013...., Washington, DC 20590, (telephone 202-493- 1342); or Kathy Schnakenberg, FRA Alcohol/Drug Program Specialist... from FRA's Management Information System, the rail industry's random drug testing positive rate has...

  2. INFLUENCE OF SYSTEMIC DISEASES AND REMOVABLE ORTHODONTIC APPLIANCES ON THE QUALITY OF SALIVA IN CHILDHOOD.

    Directory of Open Access Journals (Sweden)

    Maya Rashkova

    2012-03-01

    Full Text Available During the last 10 years numerous investigations using saliva as a diagnostic tool have been carried out. The aim of present study is to evaluate saliva qualities for various general diseases and conditions that influence its qualities. (1 Evaluation of salivary flow and saliva consistency of children. (2 Evaluation of saliva pH and buffer capacity of children. Material and Methods. The investigation was carried out with 126 children (age 6 to 17 selected by their general diseases and conditions influencing the oral risk environment. The children were divided into 4 groups: 30 children with diabetes, 25 children with asthma treated with local corticosteroids, 27 healthy children with orthodontic treatment, 34 children as a control group (healthy children. The saliva of the children was tested with the help of “Saliva Check” of GC company. The instructions of the company producer were followed.Results. Stimulated saliva current is reliably lower for children with asthma treated with local corticosteroids, diabetes and children with orthodontic appliances. Saliva pH is with lower values for children with diabetes and asthma – diseases predisposing to acid oral environment. The decreased saliva buffer capacity for children with diabetes and asthma is an indicator for the difficult regulation of the dynamically changing oral electrolytic balance of those children.Conclusion. The saliva parameters studied can be used as biomarkers of the liquid oral environment with regard to the risks for caries and periodontal diseases in children. General health status influences saliva qualities increasing thus indirectly the caries risk.

  3. Selected antibacterial factors in the saliva of diabetic patients.

    Science.gov (United States)

    Malicka, Barbara; Kaczmarek, Urszula; Skośkiewicz-Malinowska, Katarzyna

    2015-03-01

    Diabetes mellitus leads to many systemic complications, including changes in the morphology, function of the salivary glands, and the composition of saliva. The study comprised a randomly selected 156 adults, of both genders, aged from 21 to 79, out of which patients with diabetes type 1 and 2, and healthy subjects forming two control age- and gender matched to the ill subjects. In unstimulated mixed saliva, total protein, peroxidase, myeloperoxidase and immunoglobulin A were measured as well as salivary flow rate. The periodontal condition was assessed with the use of GI, mSBI and PSR index. The obtained data were analysed with the use of U Mann-Whitney's test, Spearman's rang correlation and Chi-square test at a significant level of p diabetics in comparison to healthy age and gender matched control group had a lower salivary flow rate (p diabetics in comparison to control subjects had a higher level of total protein concentration (p diabetes type 1 and 2 can cause abnormalities in salivary glands function resulting in the diminishing of salivary flow rate and the increase in total protein content. Higher levels of myeloperoxidase and IgA in the saliva can be linked to worse periodontal condition in the diabetic patients. Copyright © 2014. Published by Elsevier Ltd.

  4. The functions of human saliva

    DEFF Research Database (Denmark)

    Dawes, C; Pedersen, Anne Marie Lynge; Villa, A

    2015-01-01

    This narrative review of the functions of saliva was conducted in the PubMed, Embase and Web of Science databases. Additional references relevant to the topic were used, as our key words did not generate references which covered all known functions of saliva. These functions include maintaining a...... of oral wounds. Clearly, saliva has many functions which are needed for proper protection and functioning of the human body....... a moist oral mucosa which is less susceptible to abrasion, and removal of micro-organisms, desquamated epithelial cells, leucocytes and food debris by swallowing. The mucins form a slimy coating on all surfaces in the mouth and act as a lubricant during such processes as mastication, formation of a food...

  5. Factors That Influence the Extensional Rheological Property of Saliva.

    Directory of Open Access Journals (Sweden)

    Amrita Vijay

    Full Text Available The spinnbarkeit of saliva reflects the ability of saliva to adhere to surfaces within the mouth, thereby serving as a protective role and aiding in lubrication. Therefore, alterations in the extensional rheology of saliva may result in the loss in adhesiveness or the ability to bind onto surfaces. Mucin glycoproteins and their structures are known to be important factors for the extensional rheological properties of saliva. The conformation of mucin depends on factors such as pH and ionic strength. Chewing is one of the main stimuli for salivary secretion but creates significant sheer stress on the salivary film which could influence mouthfeel perceptions. The current study investigates the possible factors which affect the extensional rheological properties of saliva by comparing submandibular/sublingual saliva with different oral stimuli within the same group of subjects. Unstimulated and stimulated saliva (chew, smell and taste salivas were collected primarily from submandibular/sublingual glands. The saliva samples were measured for Spinnbarkeit followed by the measuring mucin, total protein, total calcium and bicarbonate concentrations. The results indicated correlations between rheological properties and mucin/ion concentrations. However, chewing stimulated submandibular/sublingual saliva is shown to have significantly lower Spinnbarkeit, but factors such as mucin, protein and calcium concentrations did not account for this variation. Analysis of the concentration of bicarbonate and pH appears to suggest that it has a prominent effect on extensional rheology of saliva.

  6. Non-Coding RNAs in Saliva: Emerging Biomarkers for Molecular Diagnostics

    Directory of Open Access Journals (Sweden)

    Blanca Majem

    2015-04-01

    Full Text Available Saliva is a complex body fluid that comprises secretions from the major and minor salivary glands, which are extensively supplied by blood. Therefore, molecules such as proteins, DNA, RNA, etc., present in plasma could be also present in saliva. Many studies have reported that saliva body fluid can be useful for discriminating several oral diseases, but also systemic diseases including cancer. Most of these studies revealed messenger RNA (mRNA and proteomic biomarker signatures rather than specific non-coding RNA (ncRNA profiles. NcRNAs are emerging as new regulators of diverse biological functions, playing an important role in oncogenesis and tumor progression. Indeed, the small size of these molecules makes them very stable in different body fluids and not as susceptible as mRNAs to degradation by ribonucleases (RNases. Therefore, the development of a non-invasive salivary test, based on ncRNAs profiles, could have a significant applicability to clinical practice, not only by reducing the cost of the health system, but also by benefitting the patient. Here, we summarize the current status and clinical implications of the ncRNAs present in human saliva as a source of biological information.

  7. Application of near-infrared spectroscopy to measurement of hemodynamic signals accompanying stimulated saliva secretion.

    Science.gov (United States)

    Sato, Hiroki; Obata, Akiko N; Moda, Ichiro; Ozaki, Kazutaka; Yasuhara, Takaomi; Yamamoto, Yukari; Kiguchi, Masashi; Maki, Atsushi; Kubota, Kisou; Koizumi, Hideaki

    2011-04-01

    We aim to test the feasibility of using near-infrared spectroscopy (NIRS) for indirect measurement of human saliva secretion in response to taste stimuli for potential application to organoleptic testing. We use an NIRS system to measure extracranial hemodynamics (Hb-signals around the temples) of healthy participants when taste stimuli are taken in their mouths. First, the Hb-signals and volume of expelled saliva (stimulated by distilled-water or sucrose-solution intake) are simultaneously measured and large Hb-signal changes in response to the taste stimuli (Hb-responses) are found. Statistical analysis show that both the Hb response and saliva volume are larger for the sucrose solution than for the distilled water with a significant correlation between them (r = 0.81). The effects of swallowing on the Hb-signals are investigated. Similar Hb responses, differing from the sucrose solution and distilled water, are obtained even though the participants swallow the mouth contents. Finally, functional magnetic resonance imaging is used to identify possible sources of the Hb signals corresponding to salivation. Statistical analysis indicates similar responses in the extracranial regions, mainly around the middle meningeal artery. In conclusion, the identified correlation between extracranial hemodynamics and the saliva volume suggests that NIRS is applicable to the measurement of hemodynamic signals accompanying stimulated saliva secretion.

  8. Cortisol in urine and saliva

    DEFF Research Database (Denmark)

    Hurwitz Eller, N; Netterstrøm, B; Hansen, Åse Marie

    2001-01-01

    The objective of the study was to analyse the relations between excretion of cortisol in urine and saliva and the intima media thickness (IMT) of the artery carotis communis.......The objective of the study was to analyse the relations between excretion of cortisol in urine and saliva and the intima media thickness (IMT) of the artery carotis communis....

  9. Effectiveness of transcutaneous electrical nerve stimulation on saliva production in post-radiated oral cancer patients

    Directory of Open Access Journals (Sweden)

    Sakshi Ojha

    2016-01-01

    Full Text Available Aims and Objectives: To determine the effectiveness of transcutaneous electrical nerve stimulation (TENS in stimulating salivary flow in post-radiated oral cancer patients, and to compare the salivary flow rate between unstimulated saliva and saliva stimulated with TENS in post-radiated oral cancer patients. Materials and Methods: In 30 patients who underwent radiotherapy for oral cancer, unstimulated saliva was collected every minute for 5 min in a graduated test tube. The TENS unit was activated and stimulated saliva was collected for 5 min in a separate graduated test tube, and the flow rate was compared with the unstimulated salivary flow rate. Results: A statistically significant improvement was seen in saliva production during stimulation (P < 0.001. In addition, statistically significant increase in TENS stimulated saliva was observed in patients aged ≥50 years compared to that in patients aged <50 years (P < 0.05. There was no significant difference in salivary flow rate between the two genders in both stimulated and unstimulated conditions, however, statistically significant increase in salivary flow rate was observed in males under stimulated condition (P < 0.01. Conclusion: TENS was highly effective in stimulating the whole salivary flow rate in post-radiated oral cancer patients. It is an effective supportive treatment modality in xerostomia patients caused by radiotherapy in oral cancer patients.

  10. Saliva, Serum Levels of Interleukin-21, -33 and Prostaglandin E2 in Patients with Generalised Aggressive or Chronic Periodontitis.

    Science.gov (United States)

    Gümüş, Pınar; Nizam, Nejat; Nalbantsoy, Ayşe; Özçaka, Özgün; Buduneli, Nurcan

    This cross-sectional study aims to evaluate saliva, serum levels of interleukin-21 (IL-21), IL-33, and prostaglandin E2 (PGE2) in patients with generalised chronic periodontitis or aggressive periodontitis. Before initiation of any periodontal treatment, saliva and serum samples were collected and clinical periodontal measurements were recorded from 94 participants (25 aggressive periodontitis patients, 25 chronic periodontitis patients, 44 periodontally healthy individuals). IL-21, IL-33 and PGE2 levels in serum and saliva samples were determined by ELISA. Data were tested statistically using Kruskal-Wallis, Mann-Whitney U-, and Spearman-rho rank tests. Saliva IL-33 levels were statistically significantly higher in the chronic than the aggressive group (p periodontitis groups. Saliva IL-33 levels correlated with age in the chronic periodontitis group (p periodontitis groups (p chronic and aggressive periodontitis, but the present findings support the role of these cytokines in periodontitis. Statistically significantly higher saliva IL-33 levels in the chronic periodontitis group warrant further research.

  11. Xylitol concentrations in artificial saliva after application of different xylitol dental varnishes

    Science.gov (United States)

    PEREIRA, Agnes de Fátima Faustino; da SILVA, Thiago Cruvinel; da SILVA, Thelma Lopes; CALDANA, Magali de Lourdes; BASTOS, José Roberto Magalhães; BUZALAF, Marília Afonso Rabelo

    2012-01-01

    Objective The present study analyzed xylitol concentrations in artificial saliva over time after application of varnishes containing 10% and 20% xylitol. Material and Methods Fifteen bovine enamel specimens (8x4 mm) were randomly allocated to 3 groups (n=5/group), according to the type of varnish used: 10% xylitol, 20% xylitol and no xylitol (control). After varnish application (4 mg), specimens were immersed in vials containing 500 µL of artificial saliva. Saliva samples were collected in different times (1, 8, 12, 16, 24, 48 and 72 h) and xylitol concentrations were analyzed. Data were assessed by two-way repeated-measures ANOVA (pxylitol in saliva samples of the control group. Salivary xylitol concentrations were significantly higher up to 8 h after application of the 20% xylitol varnish. Thereafter, the 10% xylitol varnish released larger amounts of that polyol in artificial saliva. Conclusions Despite the results in short-term, sustained xylitol releases could be obtained when the 10% xylitol varnish was used. These varnishes seem to be viable alternatives to increase salivary xylitol levels, and therefore, should be clinically tested to confirm their effectiveness. PMID:22666828

  12. The role of saliva in the process of oxidative stress – review of literature

    Directory of Open Access Journals (Sweden)

    Anna Krysińska

    2016-12-01

    Full Text Available Background: Saliva constitutes a first line of defence against free radical-mediated oxidative stress, since the process of mastication and digestion promotes lipid peroxidation. During gingival inflammation, gingival crevicular fluid flow increases the change of saliva composition with products from the inflammatory response, modulating oxidative damages in the oral cavity. Authors review the current literature concerning the reactive oxygen species, oxidants, pro-oxidants and antioxidants in saliva, and methods for assessing the antioxidant capacity of saliva. Comparison of salivary antioxidant status in male and female subjects reveales a significant gender-related difference in saliva composition. The current data demonstrate a significant enhancement of the salivary antioxidant system in juvenile idiopathic arthritis patients. Also patients with chronic renal failure, diabetes and on hemodialysis show increase oxidative stress burden in both serum and saliva. The finding of reduced oral peroxidase levels in smoking subjects may represent a contributory mechanism for initiation and progression of cigarette smoke-related oral diseases such as oral cancer. The results of recent studies indicate that the total antioxidant capacity of saliva decreased in children with HIV infection. Conclusion: Whole saliva may contain simply measured indicators of oxidative processes. This may provide a tool for the development and monitoring of new treatment strategies. A non-invasive determination of the salivary concentrations of antioxidants such as superoxide dismutase (SOD and uric acid (UR allows the evaluation of the defensive capacity of the oral mucosa. Still, there is a need for standardization of methods for saliva sampling and testing protocol.

  13. Influence of saliva contamination on the shear bond strength of adhesives on enamel

    Directory of Open Access Journals (Sweden)

    Tatiana Feres Assad-Loss

    2012-04-01

    Full Text Available OBJECTIVE: To evaluate shear bond strength of 3 adhesive systems (Single Bond, TransbondTM MIP and TransbondTM XT applied on bovine enamel under saliva contamination condition. METHOD: One hundred and twenty enamel surfaces of bovine incisors were divided into 6 groups (n = 20 according to the adhesive system used (TransbondTM XT, TransbondTM MIP and Single Bond with or without saliva contamination. For each adhesive system, there were two groups defined as no contamination group (NC: 37% H3PO4 conditioning for 30 seconds and two layers of adhesive systems; saliva contamination group (SC: After the first adhesive layer application, the examined areas were contaminated with saliva. Samples were mounted appropriately for testing and stored in deionized water at 37 ºC for 7 days. Samples were then submitted to shear bond strength trials at a speed of 0.5 mm/min. The Adhesive Remnant Index (ARI was evaluated under stereomicroscopy. Two-way analysis of variance and the Tukey test were used to compare mean values (α = 0.05. RESULTS: Groups XT (NC = 26.29 ± 7.23; MIP (NC = 24.47 ± 7.52 and SB (NC = 32.36 ± 4.14 XT (SC = 19.59 ± 6.76; MIP (SC = 18.08 ± 6.39 and SB (SC = 18.18 ± 7.03 MPa. ARI 0 and 1 were the most prevalent scores in all study groups examined. CONCLUSION: Saliva contamination significantly decreased bond strength of the three adhesive systems examined (p <0.05. However, the comparison of groups with and without saliva contamination did not reveal any significant differences, and, therefore, the three systems may be considered equivalent.

  14. Shear bond strength of metallic brackets: influence of saliva contamination

    Directory of Open Access Journals (Sweden)

    Luciana Borges Retamoso

    2009-06-01

    Full Text Available OBJECTIVE: To evaluate the influence of saliva contamination on shear bond strength and the bond failure pattern of 3 adhesive systems (Transbond XT, AdheSE and Xeno III on orthodontic metallic brackets bonded to human enamel. MATERIAL AND METHODS: Seventy-two permanent human molars were cut longitudinally in a mesiodistal direction, producing seventy-two specimens randomly divided into six groups. Each system was tested under 2 different enamel conditions: no contamination and contaminated with saliva. In T, A and X groups, the adhesive systems were applied to the enamel surface in accordance with manufacturer's instructions. In TS, AS and XS groups, saliva was applied to enamel surface followed by adhesive system application. The samples were stored in distilled water at 37ºC for 24 h, and then tested for shear bond strength in a universal testing machine (Emic, DL 2000 running at a crosshead speed of 1 mm/min. After bond failure, the enamel surfaces were observed under an optical microscope at 40x magnification. RESULTS: The control and contaminated groups showed no significant difference in shear bond strength for the same adhesive system. However, shear bond strength of T group (17.03±4.91 was significantly higher than that of AS (8.58±1.73 and XS (10.39±4.06 groups (p<0.05. Regarding the bond failure pattern, TS group had significantly higher scores of no adhesive remaining on the tooth in the bonding area than other groups considering the adhesive remnant index (ARI used to evaluate the amount of adhesive left on the enamel. CONCLUSIONS: Saliva contamination showed little influence on the 24-h shear bond strength of orthodontic brackets.

  15. Morphology and Differentiation of MG63 Osteoblast Cells on Saliva Contaminated Implant Surfaces

    Directory of Open Access Journals (Sweden)

    Neda Shams

    2015-11-01

    Full Text Available Objectives: Osteoblasts are the most important cells in the osseointegration process. Despite years of study on dental Implants, limited studies have discussed the effect of saliva on the adhesion process of osteoblasts to implant surfaces. The aim of this in vitro study was to evaluate the effect of saliva on morphology and differentiation of osteoblasts attached to implant surfaces.Materials and Methods: Twelve Axiom dental implants were divided into two groups. Implants of the case group were placed in containers, containing saliva, for 40 minutes. Then, all the implants were separately stored in a medium containing MG63 human osteoblasts for a week. Cell morphology and differentiation were assessed using a scanning electron microscope and their alkaline phosphatase (ALP activity was determined. The t-test was used to compare the two groups.Results: Scanning electron microscopic observation of osteoblasts revealed round or square cells with fewer and shorter cellular processes in saliva contaminated samples, whereas elongated, fusiform and well-defined cell processes were seen in the control group. ALP level was significantly lower in case compared to control group (P<0.05.Conclusion: Saliva contamination alters osteoblast morphology and differentiation and may subsequently interfere with successful osseointegration. Thus, saliva contamination of bone and implant must be prevented or minimized.

  16. 75 FR 3153 - Drug and Alcohol Testing Program; Correction

    Science.gov (United States)

    2010-01-20

    ... definition of prohibited drugs. In Sec. Sec. 120.103 and 120.211, we omitted the reference to Sec. 135.1 from.... FAA-2008-0937; Amendment No. 120-0A, 135-117A] RIN 2120-AJ37 Drug and Alcohol Testing Program... Aviation Administration (FAA) is correcting its drug and alcohol testing regulations published on May 14...

  17. Effect of saliva on load-deflection characteristics of superelastic nickel-titanium orthodontic wires.

    Science.gov (United States)

    Hosseinzadeh Nik, T; Ghadirian, H; Ahmadabadi, M Nili; Shahhoseini, T; Haj-Fathalian, M

    2012-01-01

    Most published results about the characteristics of NiTi wires are based on the mechanical laboratory tests on the as-received wires.The purpose of this study was to investigate the effect of saliva on load-deflection characteristics of superelastic NiTi wires. In this experimental study, 15 wires of three kinds of superelastic NiTi wires (Sentalloy, Force I and Truflex) were prepared. Five specimens of each wire were tested in the as-received condition (T0) to provide baseline information and the remaining wires were divided into two groups of five. Half of them were kept inside artificial saliva for one month (T1), while the others were kept in air (T2). After 30 days, three-point bending test was done in a dental arch model and data from selected points on the unloading phase of the generated graphs were used for statistical analysis. Force I and Truflex showed significantly greater force than Sentalloy. The load values of Truflex and Force I after one month exposed to artificial saliva (T1) decreased significantly, but Sentalloy was not affected significantly. The plateau gap values were not considerably different among T0, T1 and T2. Saliva decreased the load of Force I and Truflex significantly, but it did not have a statistically significant effect on Sentalloy.

  18. The proteome of human saliva

    Science.gov (United States)

    Griffin, Timothy J.

    2013-05-01

    Human saliva holds tremendous potential for transforming disease and health diagnostics given its richness of molecular information and non-invasive collection. Enumerating its molecular constituents is an important first step towards reaching this potential. Among the molecules in saliva, proteins and peptides arguably have the most value: they can directly indicate biochemical functions linked to a health condition/disease state, and they are attractive targets for biomarker assay development. However, cataloging and defining the human salivary proteome is challenging given the dynamic, chemically heterogeneous and complex nature of the system. In addition, the overall human saliva proteome is composed of several "sub-proteomes" which include: intact full length proteins, proteins carrying post-translational modifications (PTMs), low molecular weight peptides, and the metaproteome, derived from protein products from nonhuman organisms (e.g. microbes) present in the oral cavity. Presented here will be a summary of communal efforts to meet the challenge of characterizing the multifaceted saliva proteome, focusing on the use of mass spectrometry as the proteomic technology of choice. Implications of these efforts to characterize the salivary proteome in the context of disease diagnostics will also be discussed.

  19. The differences of saliva pH before and after application of Bis-GMA resin based-pit and fissure sealant

    Directory of Open Access Journals (Sweden)

    Ayub Irmadani Anwar

    2016-06-01

    Full Text Available Pit and fissure sealant applications is one way to prevent caries. One of the effective ingredient as a pit and fissure sealant is a Bis-GMA resin. One of the active components  of  Bis-GMA  resin  is  sodium  fluoride,  which is capable  of releasing fluoride ions to the tooth surface and able to improve the repair and remineralization process through the replacement  of  calcium and phosphate ions found in saliva to increase the pH of saliva. This study was to determine the effect of pit and fissure sealant applications made from Bis-GMA resin to pH of saliva in children aged 6-12 years. The study design is pre and post test with control group design. Saliva samples were derived from 15 pediatric patients has met the criteria. The pH of saliva were taken before and after the application of pit and fissure sealant made from Bis-GMA and measured with pH meter. This study used a non-parametric test, the Wilcoxon Signed Rank test. The results of this study are also supported by the results of statistical tests showed p-: 0.005 (p<0.05 value, which means that there are significant differences in pH of saliva before and after the application of pit and fissure sealant made from Bis-GMA resin.

  20. Is parotid saliva sterile on entry to the oral cavity?

    DEFF Research Database (Denmark)

    Schrøder, Stine A; Bardow, Allan; Eickhardt-Dalbøge, Steffen

    2017-01-01

    CONCLUSION: The present study indicates that parotid saliva is sterile on entry to the oral cavity. OBJECTIVES: The objective was to investigate if parotid saliva is sterile on entry to the oral cavity and, thus, prior to contamination by oral bacteria. METHOD: Forty healthy volunteers were...... included in sterile parotid saliva collection. Parotid saliva was collected using a sterile Lashley cup, placed over the papilla of the Stensen´s duct, as well as sterile tubes and syringes for collection. All collections were followed by collection of a positive control sample where some of the sterile...... obtained parotid saliva had been exposed to the contralateral mucosal membranes. All samples parotid saliva, as well as the positive controls, were cultivated, and 10 randomly selected parotid saliva samples underwent polymerase chain reaction (PCR) analyses. RESULTS: In 33 of 40 parotid saliva samples...

  1. Saliva levels of Abeta1-42 as potential biomarker of Alzheimer's disease: a pilot study

    Directory of Open Access Journals (Sweden)

    Antequera Desiree

    2010-11-01

    Full Text Available Abstract Background Simple, non-invasive tests for early detection of degenerative dementia by use of biomarkers are urgently required. However, up to the present, no validated extracerebral diagnostic markers for the early diagnosis of Alzheimer disease (AD are available. The clinical diagnosis of probable AD is made with around 90% accuracy using modern clinical, neuropsychological and imaging methods. A biochemical marker that would support the clinical diagnosis and distinguish AD from other causes of dementia would therefore be of great value as a screening test. A total of 126 samples were obtained from subjects with AD, and age-sex-matched controls. Additionally, 51 Parkinson's disease (PD patients were used as an example of another neurodegenerative disorder. We analyzed saliva and plasma levels of β amyloid (Aβ using a highly sensitive ELISA kit. Results We found a small but statistically significant increase in saliva Aβ42 levels in mild AD patients. In addition, there were not differences in saliva concentration of Aβ42 between patients with PD and healthy controls. Saliva Aβ40 expression was unchanged within all the studied sample. The association between saliva Aβ42 levels and AD was independent of established risk factors, including age or Apo E, but was dependent on sex and functional capacity. Conclusions We suggest that saliva Aβ42 levels could be considered a potential peripheral marker of AD and help discrimination from other types of neurodegenerative disorders. We propose a new and promising biomarker for early AD.

  2. Prevalence and persistence of male DNA identified in mixed saliva samples after intense kissing.

    Science.gov (United States)

    Kamodyová, Natália; Durdiaková, Jaroslava; Celec, Peter; Sedláčková, Tatiana; Repiská, Gabriela; Sviežená, Barbara; Minárik, Gabriel

    2013-01-01

    Identification of foreign biological material by genetic profiling is widely used in forensic DNA testing in different cases of sexual violence, sexual abuse or sexual harassment. In all these kinds of sexual assaults, the perpetrator could constrain the victim to kissing. The value of the victim's saliva taken after such an assault has not been investigated in the past with currently widely used molecular methods of extremely high sensitivity (e.g. qPCR) and specificity (e.g. multiplex Y-STR PCR). In our study, 12 voluntary pairs were tested at various intervals after intense kissing and saliva samples were taken from the women to assess the presence of male DNA. Sensitivity-focused assays based on the SRY (single-copy gene) and DYS (multi-copy gene) sequence motifs confirmed the presence of male DNA in female saliva after 10 and even 60min after kissing, respectively. For specificity, standard multiplex Y-STR PCR profiling was performed and male DNA was found in female saliva samples, as the entire Y-STR profile, even after 30min in one sample. Our study confirms that foreign DNA tends to persist for a restricted period of time in the victim's mouth, can be isolated from saliva after prompt collection and can be used as a valuable source of evidence. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Rehardening of caries-like lesions in root surfaces by saliva substitutes.

    Science.gov (United States)

    Turssi, Cecilia P; Lima, Renata Q V; Faraoni-Romano, Juliana J; Serra, Mônica C

    2006-12-01

    This study sought to evaluate whether root dentine caries-like lesions could be remineralised by saliva substitutes. Root dentine slabs (3 x 3 x 2 mm) were cut from bovine incisors, ground flat, polished and pre-tested for Knoop microhardness (KHN) at five locations spaced 500 microm apart and 500 microm from the left edge of each sectioned piece. After 60 out of the 100 slabs had been selected based upon their KHN values, specimens were coated with wax except for their outer surface. Specimens were then cycled through a highly cariogenic challenge model to induce caries-like lesions, whose formation was confirmed by KHN measurements located 500 microm from the right edge of the specimen. According to a randomised complete block design, the experimental units (n = 15) were exposed to 1.5 ml of saliva substitutes, based on either mucin (MC) or carboxymethylcellulose (CM), to natural human saliva (HS) or to 100% relative humidity (RH) over 20 days. Remineralisation was verified by KHN measurements located 1000 microm apart from the right edge of the specimen. Analysis of variance indicated a significant (p < 0.0001) difference among the KHN values attained by the carious root dentine after exposure to the remineralising agents. Tukey's test ascertained that remineralisation was greatest with MC, intermediate with CM and least with HS, but rehardening did not reach the pre-caries lesion formation values. Saliva substitutes may provide partial remineralisation to preformed caries-like lesions in root dentine.

  4. Quantitative study of non-stimulated human whole saliva using NAA

    International Nuclear Information System (INIS)

    Lewgoy, H.R.; Zamboni, C.B.; Sabrina Metairon; Medeiros, I.M.M.A.; Medeiros de, J.A.G.

    2013-01-01

    In the past few years, the use of saliva has increased as a method for diagnosis of a variety of diseases. Investigations of flow rates, pH, molecular components, hormones and proteins have presented significant progress in clinical testing as a diagnostic tool. Inorganic elements found in saliva also have important correlations that can assist in the diagnosis of periodontal disease, but these salivary components are still poorly investigated. In this study, we investigated non-stimulated whole saliva of 44 healthy subjects and 12 patients with periodontal disease, obtained from donors at Sao Paulo city (Brazil). Using neutron activation analysis (NAA) technique, we found considerable metabolic changes in the salivary composition of periodontal patients: abnormal concentrations of Br, Ca, I, K, Mg and S that may be associated with periodontal, with the most effective indicator of periodontal disease being Ca concentration. The data from healthy donors also provide a scientific basis for biomedical researches of other oral diseases. (author)

  5. Saliva as a diagnostic fluid: literature review

    OpenAIRE

    Martí Álamo, Silvia; Mancheño Franch, Aisha; Marzal Gamarra, Cristina

    2012-01-01

    There is a growing interest in diagnosis based on the analysis of saliva. This is a simple, non-invasive method of obtaining oral samples which is safe for both the health worker and the patient, not to mention allowing for simple and cost-efficient storage. The majority of studies use general saliva samples in their entirety, complex fluids containing both local and systemic sources and whose composition corresponds to that of the blood. General saliva contains a considerable ...

  6. Identifikasi epitop dari Streptococcus mutans terhadap sekretori Imunoglobulin A saliva (The identification of Streptococcus mutans epitopes to secretory Immunoglobulin A saliva

    Directory of Open Access Journals (Sweden)

    Anita Yuliati

    2005-09-01

    Full Text Available S. mutans is one of the etiology agent of dental caries, these bacteria have a surface protein of about 185 kDa named Ag I/II. The secretory of sIgA saliva to Ag I/II of S.mutans has shown to be able to prevent colonization in human oral cavity. Peptides derived from the 824 to 853 residues of the P region of antigen I/II S. mutans related to the pathogenesis of dental caries. The aim of this study was to identify the overlapping sequence of amino acids (epitope derived from the 624 to 853 residues of P of antigen I/II S. mutans to sIgA saliva on caries and caries-free subject in a observational cross sectional study. The P region of antigen I/II S.mutans was cut into 22 peptides of 9 mer sequences with an overlapping of 8 mer and an offset of 1 mer, synthesized on polyethylene pins and tested for the reactivity with an ELISA indirect method to sIgA saliva on caries and caries-free subject. The results of this study showed that amino acid sequences with TPPVKP (832–837 and TAPTKPTY (838–845 were reactive to sIgA saliva on caries and caries-free subject. The conclusion of this study was that the overlapping common sequence of amino acid (epitopes corresponding to TPPVKP (832–837 and TAPTKPTY (838–845 was identified as caries marker epitopes in human.

  7. [Concentration of calcium ions in the saliva and the value of the pH of the saliva in female and male smokers].

    Science.gov (United States)

    Nakonieczna-Rudnicka, Marta; Bachanek, Teresa; Rogowska, Wanda

    2009-01-01

    Dental decay is a pathological process of extrasomatic origin which leads to demineralization and proteolytic degradation of hard surfaces of a tooth susceptible to this disease. Saliva composition, including calcium ion concentration and its pH value, is of importance in the development of the carious process. Tobacco smoke contains toxic compounds which negatively influence oral health. The aim of the study was evaluation of the selected saliva components: protein concentration, Ca2+ concentration, pH value both in male and female smokers. The investigated group included 65 patients reporting for the treatment to the Department of Conservative Dentistry of Medical University in Lublin. In the investigated group male smokers constituted 15.38%, female smokers--20.00%, male nicotine abstinents 21.54% and female nicotine abstinent 43.08%. The study included both survey examinations of patients and biochemical examinations of the saliva. Mixed, non-stimulated saliva was used as a material for biochemical examinations. Ca2+ concentration and pH of the saliva were assayed with the use of Rapidlab 348 analyzer. Protein in the saliva was assayed with calorimetric method according to Lowry. Saliva was collected from smokers 10-120 minutes after smoking of several cigarettes. It was stated that Ca2+ and protein concentration as well as pH of the saliva were not correlated with sex and cigarette smoking or non-smoking.

  8. Effect of saliva contamination on the microshear bond strength of one-step self-etching adhesive systems to dentin.

    Science.gov (United States)

    Yoo, H M; Oh, T S; Pereira, P N R

    2006-01-01

    This study evaluated the effect of saliva contamination and decontamination methods on the dentin bond strength of one-step self-etching adhesive systems. Three commercially available "all-in-one" adhesives (One Up Bond F, Xeno III and Adper Prompt) and one resin composite (Filtek Z-250) were used. Third molars stored in distilled water with 0.5% thymol at 4 degrees C were ground with #600 SiC paper under running water to produce a standardized smear layer. The specimens were randomly divided into groups according to contamination methods: no contamination, which was the control (C); contamination of the adhesive surface with fresh saliva before light curing (A) and contamination of the adhesive surface with fresh saliva after light curing (B). Each contamination group was further subdivided into three subgroups according to the decontamination method: A1-Saliva was removed by a gentle air blast and the adhesive was light-cured; A2-Saliva was rinsed for 10 seconds, gently air-dried and the was adhesive light-cured; A3-Saliva was rinsed and dried as in A2, then the adhesive was re-applied to the dentin surface and light-cured; B1-Saliva was removed with a gentle air blast; B2-Saliva was rinsed and dried; B3-Saliva was rinsed, dried and the adhesive was re-applied and light cured. Tygon tubes filled with resin composite were placed on each surface and light cured. All specimens were stored in distilled water at 37 degrees C for 24 hours. Microshear bond strength was measured using a universal testing machine (EZ test), and data were analyzed by one-way ANOVA followed by the Duncan test to make comparisons among the groups (p0.05). Bond strengths of all B groups were significantly lower compared to the controls (pcontamination after adhesive curing. There was no statistically significant difference among the control groups (p>0.05).

  9. Efek Pengunyahan Permen Karet Gula dan Xylitol terhadap Status Saliva

    Directory of Open Access Journals (Sweden)

    Lisna Kurnia Rezky

    2016-11-01

    Full Text Available Latar belakang. Rongga mulut sebagai pintu masuk makanan ke dalam tubuh selalu dibasahi oleh saliva setiap harinya. Saat ini banyak produk permen karet yang beredar di masyarakat yang mengandung gula dan xylitol. Banyak orang yang gemar mengunyah permen karet dengan kurang memperhatikan komposisinya baik yang mengandung gula ataupun xylitol sehingga kurang mengetahui efek masing-masing jenis permen karet tersebut terhadap kesehatan rongga mulut. Tujuan. Penelitian ini bertujuan untuk mengetahui efek pengunyahan permen karet gula dengan permen karet xylitol terhadap status saliva yang terdiri dari volume, pH, dan viskositas saliva. Metode penelitian. Subjek penelitian berjumlah 30 orang dibagi menjadi 3 kelompok masing-masing 10 orang, terdiri dari kelompok mengunyah permen karet gula, xylitol, dan kontrol dengan mengunyah apel. Pengambilan saliva dilakukan pagi hari dan siang hari. Subjek mengunyah 2 butir permen karet dan tidak diperbolehkan untuk makan dan minum 1 jam sebelum mengunyah. Subjek diinstruksikan meludah ke dalam pot saliva selama 10 menit dalam interval setiap 1 menit. Pengukuran volume saliva menggunakan pipet volume, pH saliva dengan menggunakan pH meter, dan viskositas saliva dengan menggunakan viskometer Ostwald hari ke-1 dan ke-4. Analisis data dengan uji statistik Mann-Whitney. Hasil. penelitian menunjukkan adanya peningkatan bermakna volume dan viskositas saliva pada pengunyahan permen karet xylitol dan gula. Derajat keasaman (pH saliva menurun setelah mengunyah permen karet gula sedangkan pada perm en karet xylitol relatif stabil. Disimpulkan bahwa permen karet xylitollebih baik untuk kestabilan status saliva dibandingkan permen karet gula.

  10. Chronic alcoholism-mediated metabolic disorders in albino rat testes.

    Science.gov (United States)

    Shayakhmetova, Ganna M; Bondarenko, Larysa B; Matvienko, Anatoliy V; Kovalenko, Valentina M

    2014-09-01

    There is good evidence for impairment of spermatogenesis and reductions in sperm counts and testosterone levels in chronic alcoholics. The mechanisms for these effects have not yet been studied in detail. The consequences of chronic alcohol consumption on the structure and/or metabolism of testis cell macromolecules require to be intensively investigated. The present work reports the effects of chronic alcoholism on contents of free amino acids, levels of cytochrome P450 3A2 (CYP3A2) mRNA expression and DNA fragmentation, as well as on contents of different cholesterol fractions and protein thiol groups in rat testes. Wistar albino male rats were divided into two groups: I - control (intact animals), II - chronic alcoholism (15% ethanol self-administration during 150 days). Following 150 days of alcohol consumption, testicular free amino acid content was found to be significantly changed as compared with control. The most profound changes were registered for contents of lysine (-53%) and methionine (+133%). The intensity of DNA fragmentation in alcohol-treated rat testes was considerably increased, on the contrary CYP3A2 mRNA expression in testis cells was inhibited, testicular contents of total and etherified cholesterol increased by 25% and 45% respectively, and protein SH-groups decreased by 13%. Multidirectional changes of the activities of testicular dehydrogenases were detected. We thus obtained complex assessment of chronic alcoholism effects in male gonads, affecting especially amino acid, protein, ATP and NADPH metabolism. Our results demonstrated profound changes in testes on the level of proteome and genome. We suggest that the revealed metabolic disorders can have negative implication on cellular regulation of spermatogenesis under long-term ethanol exposure.

  11. Formulation, evaluation, and comparison of bilayered and multilayered mucoadhesive buccal devices of propranolol hydrochloride.

    Science.gov (United States)

    Patel, Vishnu M; Prajapati, Bhupendra G; Patel, Madhabhai M

    2007-03-16

    The purpose of this research work was to establish mucoadhesive buccal devices of propranolol hydrochloride (PRH) in the forms of bilayered and multilayered tablets. The tablets were prepared using sodium carboxymethylcellulose (SCMC) and Carbopol-934 (CP) as bioadhesive polymers to impart mucoadhesion and ethyl cellulose (EC) to act as an impermeable backing layer. Buccal devices were evaluated by different parameters such as weight uniformity, content uniformity, thickness, hardness, surface pH, swelling index, ex vivo mucoadhesive strength, ex vivo mucoadhesion time, in vitro drug release, and in vitro drug permeation. As compared with bilayered tablets, multilayered tablets showed slow release rate of drug with improved ex vivo bioadhesive strength and enhanced ex vivo mucoadhesion time. The mechanism of drug release was found to be non-Fickian diffusion (value of n between 0.5 and 1.0) for both the buccal devices. The stability of drug in both the optimized buccal devices was tested for 6 hours in natural human saliva; both the buccal devices were found to be stable in natural human saliva. The present study concludes that mucoadhesive buccal devices of PRH can be a good way to bypass the extensive hepatic first-pass metabolism and to improve the bioavailability of PRH.

  12. Disposable Collection Kit for Rapid and Reliable Collection of Saliva

    OpenAIRE

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 ?l) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method...

  13. Multiple sclerosis test or the 4 humors: cerebrospinal fluid serum, tears and saliva; Esclerosis multiple test de los 4 humores: liquido cefalorraquideo, suero, lagrimas y saliva

    Energy Technology Data Exchange (ETDEWEB)

    Oehninger Gatti, C; Buzo Del Puerto, R; Chouza Antelo, C; Scotti Bianchi, C; Cibils, D; Alcantara Pelaez, J; Gomez, A; Heuguerot Oliveira, C

    1994-12-15

    4 were studied biological fluids easily accessible to the immune exploration (cerebrospinal fluid, serum, tears and saliva) in 25 patients with Multiple Sclerosis (MS) during a push clinical disease. The level of interleukin-2 receptor soluble (RsIL-2) was significantly increased by at least 3 of these 4 fluids, compared with normal controls. The sensitivity and specificity of its determination for the diagnosis of the condition was higher than other immunochemical parameters, oligoclonal distribution (OD) of immunoglobulin (Ig) light chain imbalance-and-evoked electrophysiological studies. This method is used to establish a more accurate diagnosis of Multiple Sclerosis as well as to monitor its biological activity with nuclear magnetic resonance (NMR) (Author) [Spanish] Se estudiaron 4 fluidos biologicos de facil acceso a la exploracion inmune (liquido cefalorraquideo, suero, lagrimas y saliva) en 25 pacientes con Esclerosis Multiple (EM) obtenidos durante un empuje clinico de la enfermedad. El nivel del receptor de Interleukina-2 soluble (RsIL-2) se encontro significativamente aumentado en por lo menos 3 de estos 4 fluidos, en comparacion con el de los controles normales. La sensibilidad y especificidad de su determinacion para el diagnostico de la afeccion, fue mayor que la de otros parametros inmunoquimicos - distribucion oligoclonal (DO) de inmunoglobulinas (Ig), disbalance de cadenas livianas - y estudios electrofisiologicos -potenciales evocados-. Este metodo es utilizado para establecer un diagnostico mas certero de la Esclerosis Multiple asi como tambien para monitorizar su actividad biologica junto con la resonancia magnetica nuclear (RMN)(Author)

  14. ALCOHOL I

    African Journals Online (AJOL)

    Despite the increase in alcohol marketing activities by the transnational alcohol corporations in Nigeria .... were recorded with a digital device with ..... era (i.e., before alcohol industry was es- tablished in ..... university student drinking: A na-.

  15. Parámetros inflamatorios en saliva y sangre en niños y adolescentes sanos Inflammatory parameters in saliva and blood from healthy children and adolescents

    Directory of Open Access Journals (Sweden)

    Ninoska Tahis Viera Sirit

    2011-09-01

    como fluido corporal que permita sustituir la determinación sérica de IL-1, IL-6 y sustancias reactivas al ácido tiobarbitúrico. En cuanto al TNF-a se evidenció una correlación significativa, lo cual podría plantear la posible sustitución de muestras séricas por salivales.At present times, there is interest in the use of saliva as a diagnosis, prediction and progression alternative of different pathologies in relation to the body fluids. To correlate the concentrations of IL-1, IL-6, TNF-a, substances reactive to thiobarbituric acid (RSTBA and O2- in the saliva and blood of systematically healthy children and adolescents. A cross-sectional study was performed in 23 healthy children and adolescents aged from 4 to 17 underwent to clinical tests to demonstrate the oral conditions and immunological to identify the cytokine levels and the RSTBAs by colorimetry trial. There was a significant difference in saliva samples compared to that of peripheral blood in study cytokines and RSTBAs: IL-1 (blood: 1.646 ± 0.13 pg/mL, saliva: 552.36 ± 75.7 pg/mL; IL-6 (blood: 3.506 ± 1.85 pg/mL, saliva: 26.89 ± 9.97 pg/mL: TNF-a (blood: 12.91 ± 3.05 pg/mL, saliva: 43.56 ± 6.44 pg/mL, RSTBA (blood: 9.46 ± 3.26 nmol/mL, saliva: 1.26 ± 0.03 nmol/mL. There was not a statistically significant difference among blood and saliva samples for IL-1, IL-6 and RSTBA values. As regards TNF-a it was demonstrated a significant correlation, r s= 0.78. There was not evidence of cells positive to O2 in study samples. Results of correlation analysis obtained among the saliva and serum samples not offer evidences that saliva may be used as body fluid allows substituting the serum determination of IL-1, IL-6 and RSTBA. In the case of the TNF-a, there was a significant correlation, which could to propose the possible substitution of serum samples for the salivary ones.

  16. Saliva transit in patients with gastroesophageal reflux disease.

    Science.gov (United States)

    Cassiani, R A; Mota, G A; Aprile, L R O; Dantas, R O

    2015-10-01

    Saliva is an important factor in the neutralization of the acidity of the refluxed material that comes from the stomach to the esophagus. The impairment of saliva transit from oral cavity to distal esophagus may be one of the causes of esophagitis and symptoms in gastroesophageal reflux disease (GERD). With the scintigraphic method, the transit of 2 mL of artificial saliva was measured in 30 patients with GERD and 26 controls. The patients with GERD had symptoms of heartburn and acid regurgitation, a 24-hour pH monitoring with more than 4.2% of the time with pH below four, 26 with erosive esophagitis, and four with non-erosive reflux disease. Fourteen had mild dysphagia for solid foods. Twenty-one patients had normal esophageal manometry, and nine had ineffective esophageal motility. They were 15 men and 15 women, aged 21-61 years, mean 39 years. The control group had 14 men and 12 women, aged 19-61 years, mean 35 years. The subjects swallowed in the sitting and supine position 2 mL of artificial saliva labeled with 18 MBq of (99m) Technetium phytate. The time of saliva transit was measured from oral cavity to esophageal-gastric transition, from proximal esophagus to esophageal-gastric transition, and the transit through proximal, middle, and distal esophageal body. There was no difference between patients and controls in the time for saliva to go from oral cavity to esophageal-gastric transition, and from proximal esophagus to esophageal-gastric transition, in the sitting and supine positions. In distal esophagus in the sitting position, the saliva transit duration was shorter in patients with GERD (3.0 ± 0.8 seconds) than in controls (7.6 ± 1.7 seconds, P = 0.03). In conclusion, the saliva transit from oral cavity to the esophageal-gastric transition in patients with GERD has the same duration than in controls. Saliva transit through the distal esophageal body is faster in patients with GERD than controls. © 2014 International Society for Diseases of the

  17. 49 CFR 40.273 - What is the effect of a cancelled alcohol test?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What is the effect of a cancelled alcohol test? 40.273 Section 40.273 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Alcohol Testing § 40.273 What is the...

  18. Biomonitorization of cadmium, chromium, manganese, nickel and lead in whole blood, urine, axillary hair and saliva in an occupationally exposed population

    Energy Technology Data Exchange (ETDEWEB)

    Gil Fernando, E-mail: fgil@ugr.es [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain); Hernandez, Antonio F. [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain); Marquez, Claudia [Internal Resident in Occupational Medicine, School of Occupational Medicine of University of Granada (Spain); Femia, Pedro [Department of Statistics, University of Granada, School of Medicine (Spain); Olmedo, Pablo; Lopez-Guarnido, Olga; Pla, Antonio [Department of Legal Medicine and Toxicology, University of Granada, School of Medicine (Spain)

    2011-02-15

    Heavy metal contamination from occupational origin is a cause for concern because of its potential accumulation in the environment and in living organisms leading to long term toxic effects. This study was aimed to assess Cd, Cr, Mn, Ni and Pb levels in whole blood, urine, axillary hair and saliva from 178 individuals with occupational exposure to heavy metals. Levels of metal compounds were determined by atomic absorption spectrometry. We collected information on occupation, lifestyle habits and food intake by questionnaire. Multiple linear regression analyses for metal ion concentration in whole blood, urine, axillary hair and saliva were adjusted for age, gender, smoking and alcohol consumption, lifetime workplace exposure, residence area and food habits. Overall, blood and urine median concentrations found for the five metals analyzed do not exceed biological exposure indexes, so that they are very similar to a non-occupationally exposed population. Toxicokinetic differences may account for the lack of correlations found for metal levels in hair and saliva with those in blood or urine. For those heavy metals showing higher median levels in blood with respect to hair (Cd, Mn and Pb) indicating lesser hair incorporation from blood, the lifetime working experience was inversely correlated with their hair levels. The longer the lifetime working experience in industrial environments, the higher the Mn and Ni concentration in saliva. Axillary hair and saliva may be used as additional and/or alternative samples to blood or urine for biomonitoring hair Mn, and saliva Ni in subjects with occupational exposure. - Research Highlights: {yields} Metal levels in workers were similar to an occupationally non-exposed population. {yields} Metal levels in blood and urine were below recommended reference values. {yields} A lack of correlation was observed between metal levels in blood and saliva. {yields} Toxicokinetic differences may account for the lack of correlations observed

  19. Saliva: Physiology and Diagnostic Potential in Health and Disease

    Directory of Open Access Journals (Sweden)

    Sebastien J. C. Farnaud

    2010-01-01

    Full Text Available Saliva has been described as the mirror of the body. In a world of soaring healthcare costs and an environment where rapid diagnosis may be critical to a positive patient outcome, saliva is emerging as a viable alternative to blood sampling. In this review, we discuss the composition and various physiological roles of saliva in the oral cavity, including soft tissue protection, antimicrobial activities, and oral tissue repair. We then explore saliva as a diagnostic marker of local oral disease and focus particularly on oral cancers. The cancer theme continues when we focus on systemic disease diagnosis from salivary biomarkers. Communicable disease is the focus of the next section where we review the literature relating to the direct and indirect detection of pathogenic infections from human saliva. Finally, we discuss hormones involved in appetite regulation and whether saliva is a viable alternative to blood in order to monitor hormones that are involved in satiety.

  20. The ad-libitum alcohol 'taste test': secondary analyses of potential confounds and construct validity.

    Science.gov (United States)

    Jones, Andrew; Button, Emily; Rose, Abigail K; Robinson, Eric; Christiansen, Paul; Di Lemma, Lisa; Field, Matt

    2016-03-01

    Motivation to drink alcohol can be measured in the laboratory using an ad-libitum 'taste test', in which participants rate the taste of alcoholic drinks whilst their intake is covertly monitored. Little is known about the construct validity of this paradigm. The objective of this study was to investigate variables that may compromise the validity of this paradigm and its construct validity. We re-analysed data from 12 studies from our laboratory that incorporated an ad-libitum taste test. We considered time of day and participants' awareness of the purpose of the taste test as potential confounding variables. We examined whether gender, typical alcohol consumption, subjective craving, scores on the Alcohol Use Disorders Identification Test and perceived pleasantness of the drinks predicted ad-libitum consumption (construct validity). We included 762 participants (462 female). Participant awareness and time of day were not related to ad-libitum alcohol consumption. Males drank significantly more alcohol than females (p alcohol consumption (p = 0.04), craving (p alcohol consumption. The construct validity of the taste test was supported by relationships between ad-libitum consumption and typical alcohol consumption, craving and pleasantness ratings of the drinks. The ad-libitum taste test is a valid method for the assessment of alcohol intake in the laboratory.

  1. Comparação entre a utilização de saliva e sangue para determinação do lactato mínimo em cicloergômetro e ergômetro de braço em mesa-tenistas Comparacion entre la utilizacion de saliva y sangre para la determinacion del lactato mínimo en cicloergómetro y ergómetro de brazo en tenistas de mesa Comparison between the use of saliva and blood for the minimum lactate determination in arm ergometer and cycle ergometer in table tennis players

    Directory of Open Access Journals (Sweden)

    Alessandro Moura Zagatto

    2004-12-01

    Full Text Available O objetivo do estudo foi verificar a possibilidade de determinar o teste de lactato mínimo (TLM com concentrações de sódio (Na+, potássio (K+ e lactato (LAC na saliva em ergômetro de braço e cicloergômetro. Foram participantes deste estudo oito mesa-tenistas de nível internacional. Como estímulo anaeróbio no TLM em ambos os ergômetros foram utilizados testes máximos de 30 segundos. No ergômetro de braço isocinético (Cybex Ube 2432 foi aplicada a força máxima com rotação fixa em 102rpm e no cicloergômetro, aplicada a carga de 7,5% do peso corporal (Kp. Após o estímulo anaeróbio no ergômetro de braço, foi iniciado um teste incremental com rotações na manivela constante a 60rpm, iniciado a 49 watts com aumento de 16 watts a cada estágio de três minutos de exercício. A intensidade correspondente ao TLM foi determinado com amostras de sangue e saliva (LACmin braço; Na+min braço-saliva e K+min braço-saliva, respectivamente. Para o cicloergômetro, a carga inicial foi de 85 watts e aumento de 17 watts com rotação do pedal constante a 70rpm. Cada estágio de exercício também teve a duração de três minutos. O LACmin foi determinado utilizando amostras de sangue e saliva (LACmin ciclo; Na+min ciclo-saliva, K+min ciclo-saliva e LACmin ciclo-saliva, respectivamente. Em ambos os ergômetros, as intensidades obtidas no TLM foram correspondentes à derivada zero do ajuste polinomial entre metabólito versus intensidade. Foram utilizados, como procedimentos estatísticos, o teste ANOVA One Way, teste t de Student pareado e teste de correlação de Pearson com níveis de significância de 5%. Os LACmin determinados com amostras de sangue e de saliva, tanto para o ergômetro de braço (LACmin braço 91,71 ± 12,43; Na+min braço-saliva 71,99 ± 23,42; K+min braço-saliva 79,67 ± 17,72, quanto para cicloergômetro (LACmin ciclo 157,68 ± 13,48; LACmin ciclo-saliva 135,49 ± 33,2; Na+min ciclo-saliva 121,81 ± 51,31; K

  2. 49 CFR 655.49 - Refusal to submit to a drug or alcohol test.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Refusal to submit to a drug or alcohol test. 655... TRANSIT ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PREVENTION OF ALCOHOL MISUSE AND PROHIBITED DRUG USE IN TRANSIT OPERATIONS Types of Testing § 655.49 Refusal to submit to a drug or alcohol test. (a) Each...

  3. The validity of the Michigan Alcoholism Screening Test (MAST)

    DEFF Research Database (Denmark)

    Storgaard, H; Nielsen, S D; Gluud, C

    1994-01-01

    This review examines the validity of the Michigan Alcoholism Screening Test (MAST) as a screening instrument for alcohol problems. Studies that compare the MAST-questionnaire with other defined diagnostic criteria of alcohol problems were retrieved through MEDLINE and a cross-bibliographic check....... A total of 20 validity studies were included. The studies varied considerably regarding the prevalence of alcohol problems, the diagnostic criteria, and the examined patient categories. The MAST compared with other diagnostic criteria of alcohol problems gave validity measures with the following span...... and the specificities show substantial variations. The variables that seem to have the largest influence on the PVpos seem to be the prevalence of alcohol problems, the diagnostic method against which the MAST-questionnaire is validated, and the populations on which the MAST is applied. The MAST should in the future...

  4. HEPATITIS B VIRUS DNA IN SALIVA FROM CHILDREN WITH CHRONIC HEPATITIS B INFECTION IMPLICATIONS FOR SALIVA AS A POTENTIAL MODE OF HORIZONTAL TRANSMISSION

    NARCIS (Netherlands)

    Heiberg, Ida Louise; Hoegh, Mette; Ladelund, Steen; Niesters, Hubert G. M.; Hogh, Birthe

    2010-01-01

    To explore the mechanism of horizontal transmission of hepatitis B virus (HBV) among children, we investigated the quantitative relationship between HBV in saliva and blood from 46 children with chronic hepatitis B. We found high levels of HBV DNA in saliva of HBeAg (+) children, suggesting saliva

  5. Hepatitis B virus DNA in saliva from children with chronic hepatitis B infection: implications for saliva as a potential mode of horizontal transmission

    DEFF Research Database (Denmark)

    Heiberg, Ida Louise; Hoegh, Mette; Ladelund, Steen

    2010-01-01

    To explore the mechanism of horizontal transmission of hepatitis B virus (HBV) among children, we investigated the quantitative relationship between HBV in saliva and blood from 46 children with chronic hepatitis B. We found high levels of HBV DNA in saliva of HBeAg (+) children, suggesting saliva...

  6. Caffeine dependence in combination with a family history of alcoholism as a predictor of continued use of caffeine during pregnancy.

    Science.gov (United States)

    Svikis, Dace S; Berger, Nathan; Haug, Nancy A; Griffiths, Roland R

    2005-12-01

    The purpose of the study was to examine whether caffeine dependence and a family history of alcoholism are associated with continued use of caffeine during pregnancy. Forty-four women seeking obstetrical care in an office-based practice completed questionnaires and provided saliva samples at three prenatal visits occurring 2-3, 3-4, and 7 months postconception. On visit 1, the patients received the physician's instructions to stop using caffeine. Structured interviews were used to assign a diagnosis of caffeine dependence (lifetime) and to identify family history of alcoholism. Outcome measures included self-reported levels of caffeine use and saliva caffeine levels at the three prenatal visits. Although most women eliminated or substantially reduced their caffeine consumption between pregnancy awareness and prenatal visit 1, those with a lifetime diagnosis of caffeine dependence and a family history of alcoholism had higher levels of caffeine use and lower rates of abstinence throughout pregnancy. Saliva caffeine levels confirmed these effects. Withdrawal symptoms, functional impairment, and craving were cited as reasons they failed to eliminate or cut back on caffeine use. Fifty percent of the women with both a lifetime diagnosis of caffeine dependence and a family history of alcoholism continued to use caffeine in amounts (>300 mg/day) greater than those considered safe during pregnancy, compared to none of the women without caffeine dependence and a family history of alcoholism. Women with a lifetime diagnosis of caffeine dependence and a family history of alcoholism also reported higher rates of past cigarette smoking and problematic alcohol use. Caffeine-dependent women with a family history of alcoholism were not able to follow their physician's advice to reduce or eliminate caffeine consumption during pregnancy, despite their wanting to do so. This subgroup may require more intensive intervention to ensure caffeine abstinence and may be at greater risk for

  7. Dynamic changes in saliva after acute mental stress

    Science.gov (United States)

    Naumova, Ella A.; Sandulescu, Tudor; Bochnig, Clemens; Khatib, Philipp Al; Lee, Wing-Kee; Zimmer, Stefan; Arnold, Wolfgang H.

    2014-01-01

    Stress-related variations of fluoride concentration in supernatant saliva and salivary sediment, salivary cortisol, total protein and pH after acute mental stress were assessed. The hypothesis was that stress reactions have no influence on these parameters. Thirty-four male students were distributed into two groups: first received the stress exposure followed by the same protocol two weeks later but without stress exposure, second underwent the protocol without stress exposure followed by the stress exposure two weeks later. The stressor was a public speech followed by tooth brushing. Saliva was collected before, immediately after stress induction and immediately, at 10, 30 and 120 min. after tooth brushing. Cortisol concentrations, total protein, intraoral pH, and fluoride content in saliva were measured. The data were analyzed statistically. Salivary sediment was ca 4.33% by weight of whole unstimulated saliva. Fluoride bioavailability was higher in salivary sediment than in supernatant saliva. The weight and fluoride concentration was not altered during 2 hours after stress exposure. After a public speech, the salivary cortisol concentration significantly increased after 20 minutes compared to the baseline. The salivary protein concentration and pH also increased. Public speaking influences protein concentration and salivary pH but does not alter the fluoride concentration of saliva. PMID:24811301

  8. Different saliva substitutes for treatment of xerostomia following radiotherapy. A prospective crossover study

    International Nuclear Information System (INIS)

    Momm, F.; Volegova-Neher, N.J.; Guttenberger, R.; Schulte-Moenting, J.

    2005-01-01

    Background and purpose: xerostomia is an important chronic side effect of radiotherapy in the head and neck area. The authors investigated the efficacy of different artificial saliva compounds in patients with postirradiation xerostomia. Patients and methods: in 120 patients with xerostomia after radiotherapy for head and neck cancer, four different saliva substitute compounds (gel, carmellose spray, oil, mucin spray) were tested in a prospective crossover design. Xerostomia at baseline and under treatment with each compound was measured with a questionnaire approved in a pilot trial. Results: all compounds significantly improved xerostomia when compared to baseline situation (p < 0.0001). The gel was rated best, the carmellose spray was rated worst by the patients, but the single compounds did not differ significantly in their effects. In spite of this result, most patients chose the carmellose spray as their favorite compound. This is due to its good taste and easy handling, which play an important role for the acceptance of the products. Big individual differences in the preference of the single compounds were found. Conclusion: for most patients considerable relief from xerostomia can be reached by saliva substitutes. Thus, every patient with xerostomia should be given different artificial saliva compounds for a test period. This will help to find the individually best way to cope with the dry mouth. (orig.)

  9. Microbial profile comparisons of saliva, pooled and site-specific subgingival samples in periodontitis patients.

    Directory of Open Access Journals (Sweden)

    Daniel Belstrøm

    Full Text Available The purpose of this study was to compare microbial profiles of saliva, pooled and site-specific subgingival samples in patients with periodontitis. We tested the hypotheses that saliva can be an alternative to pooled subgingival samples, when screening for presence of periopathogens.Site specific subgingival plaque samples (n = 54, pooled subgingival plaque samples (n = 18 and stimulated saliva samples (n = 18 were collected from 18 patients with generalized chronic periodontitis. Subgingival and salivary microbiotas were characterized by means of HOMINGS (Human Oral Microbe Identification using Next Generation Sequencing and microbial community profiles were compared using Spearman rank correlation coefficient.Pronounced intraindividual differences were recorded in site-specific microbial profiles, and site-specific information was in general not reflected by pooled subgingival samples. Presence of Porphyromonas gingivalis, Treponema denticola, Prevotella intermedia, Filifactor alocis, Tannerella forsythia and Parvimona micra in site-specific subgingival samples were detected in saliva with an AUC of 0.79 (sensitivity: 0.61, specificity: 0.94, compared to an AUC of 0.76 (sensitivity: 0.56, specificity: 0.94 in pooled subgingival samples.Site-specific presence of periodontal pathogens was detected with comparable accuracy in stimulated saliva samples and pooled subgingival plaque samples. Consequently, saliva may be a reasonable surrogate for pooled subgingival samples when screening for presence of periopathogens. Future large-scale studies are needed to confirm findings from this study.

  10. Perceived Physical Availability of Alcohol at Work and Workplace Alcohol Use and Impairment: Testing a Structural Model

    Science.gov (United States)

    Frone, Michael R.; Trinidad, Jonathan R.

    2014-01-01

    This study develops and tests a new conceptual model of perceived physical availability of alcohol at work that provides unique insight into three dimensions of workplace physical availability of alcohol and their direct and indirect relations to workplace alcohol use and impairment. Data were obtained from a national probability sample of 2,727 U.S. workers. The results support the proposed conceptual model and provide empirical support for a positive relation of perceived physical availability of alcohol at work to workplace alcohol use and two dimensions of workplace impairment (workplace intoxication and workplace hangover). Ultimately, the findings suggest that perceived physical availability of alcohol at work is a risk factor for alcohol use and impairment during the workday, and that this relation is more complex than previously hypothesized. PMID:25243831

  11. DNA methylation analysis from saliva samples for epidemiological studies.

    Science.gov (United States)

    Nishitani, Shota; Parets, Sasha E; Haas, Brian W; Smith, Alicia K

    2018-06-18

    Saliva is a non-invasive, easily accessible tissue, which is regularly collected in large epidemiological studies to examine genetic questions. Recently, it is becoming more common to use saliva to assess DNA methylation. However, DNA extracted from saliva is a mixture of both bacterial and human DNA derived from epithelial and immune cells in the mouth. Thus, there are unique challenges to using salivary DNA in methylation studies that can influence data quality. This study assesses: (1) quantification of human DNA after extraction; (2) delineation of human and bacterial DNA; (3) bisulfite conversion (BSC); (4) quantification of BSC DNA; (5) PCR amplification of BSC DNA from saliva and; (6) quantitation of DNA methylation with a targeted assay. The framework proposed will allow saliva samples to be more widely used in targeted epigenetic studies.

  12. Hardness of enamel exposed to Coca-Cola and artificial saliva.

    Science.gov (United States)

    Devlin, H; Bassiouny, M A; Boston, D

    2006-01-01

    The purpose of this study was to determine the rate of change in indentation hardness of enamel in permanent teeth exposed to Coca-Cola. In a further experiment, the ability of a commercially available artificial saliva to remineralize enamel treated with Coca-Cola was tested. Ten enamel specimens were randomly chosen to be treated with Coca-Cola (experimental groups) and seven with water (control group). The fluids were applied for 1, 2, 3 h and overnight (15 h), washed off with a few drops of water and the moist enamel indentation hardness tested after each interval. With Coca-Cola treatment, the mean enamel hardness was 92.6% (s.d. = 7.9) of the original baseline hardness after 1 h, 93.25% (s.d. = 10.15) after 2 h, 85.7% (s.d. = 12.03) after 3 h and 80.3% after 15 h. The mean indentation hardness of control specimens treated with water was 108.7% (s.d. = 16.09) of the original hardness after 1 h, 99.09% (s.d. = 18.98) after 2 h, 98.97% (s.d. =11.24) after 3 h and 98.42% (s.d. = 22.78) after 15 h. In a separate experiment, the hardness of 9 enamel specimens was tested, as previously described, before and after treatment with Coca-Cola overnight and again after application of artificial saliva for 3 min. Coca-Cola reduced the mean indentation hardness of enamel in the teeth, but the hardness was partially restored with artificial saliva (Salivart) and increased by 18% from the demineralized enamel hardness.

  13. Solubility of root-canal sealers in water and artificial saliva.

    Science.gov (United States)

    Schäfer, E; Zandbiglari, T

    2003-10-01

    To compare the weight loss of eight different root-canal sealers in water and in artificial saliva with different pH values. For standardized samples (n = 12 per group), ring moulds were filled with epoxy resin (AH 26, AH Plus)-, silicone (RSA RoekoSeal)-, calcium hydroxide (Apexit, Sealapex)-, zinc oxide-eugenol (Aptal-Harz)-, glass-ionomer (Ketac Endo)- and polyketone (Diaket)-based sealers. These samples were immersed in double-distilled water or artificial saliva with different pH values (7.0, 5.7 and 4.5) for 30 s, 1 min, 2 min, 5 min, 10 min, 20 min, 1 h, 2 h, 10 h, 24 h, 48 h, 72 h, 14 days and 28 days. Mean loss of weight was determined and analysed statistically using a one-way anova and Student-Newman-Keuls test for all pairwise comparisons. Most sealers were of low solubility, although Sealapex, Aptal-Harz and Ketac Endo showed a marked weight loss in all liquids. Even after 28 days of storage in water, AH 26, AH Plus, RSA RoekoSeal, and Diaket showed less than 3% weight loss. At exposure times greater than 14 days, Sealapex showed the significantly greatest weight loss of all sealers tested (P < 0.05). Aptal-Harz and Ketac Endo were significantly more soluble in saliva (pH 4.5) than in water (P < 0.05). Under the conditions of the present study, AH Plus showed the least weight loss of all sealers tested, independent of the solubility medium used. Sealapex, Aptal-Harz and Ketac Endo had a marked weight loss in all liquids.

  14. Total anti-oxidant capacity of saliva in chronic periodontitis patients before and after periodontal treatment.

    Science.gov (United States)

    Shirzaiy, M; Ansari, S M; Dehghan, J H; Ghaeni, S H

    2014-01-01

    Periodontal disease is among the most common inflammatory conditions which is associated with many different factors. One of the contributing factors to the pathogenesis of this condition may compromise the defensive mechanism of antioxidants. The present study evaluates the antioxidant capacity of saliva in periodontal patients before and after periodontal treatment. In this cross sectional study, 31 patients systemically healthy non smokers with chronic periodontitis were recruited. The antioxidant capacity of saliva was measured before the initial phase of periodontal therapy and after completion of the treatment. Data were analyzed using SPSS 19 software. Paired T-Test, Independent sample T-test and ANOVA tests were used as appropriated. The mean and standard deviation antioxidant capacity of the saliva after the treatment.(0.962± 0.287µM)was significantly higher than before the treatment (0.655 ± 0.281 µM ,pperiodontal treatment was higher among men than among women; however, the difference was not significant (P=0.07). The mean difference of salivary antioxidant capacity was not significantly differed among different ages (P=0.772). The antioxidant capacity of saliva was higher after periodontal therapy among patients with periodontal disease, however the change was not varied across the ages and gender. Therefore, the alterations in the defensive mechanism of antioxidants could be the key factors contribute to the pathogenesis of periodontal diseases.

  15. Use of phyllosilicates in electrochemical devices: possible use of sepiolite as a support of catalysts in direct alcohol fuel cells (DAFC)

    International Nuclear Information System (INIS)

    Parra-Silva, J.; Silva, A.C.; Mello-Castanho, S.R.H.; Cerpa, A.

    2014-01-01

    Direct alcohol Fuel cells (DAFC) are interesting to use Brazil for reasons of fuel logistics and availability. The catalysts used in these devices to promote the oxidation of alcohol at the anode need to be fixed on a substrate which must provide high specific surface area, porosity, chemical and thermal resistance, this target can be achieved with the characteristics sepiolite. This paper proposes sepiolite as catalyst support for DAFC. Sepiolite is a phyllosilicate with double layered tetrahedral silicon cells and fibrillar structure. Catalysts (Pt / Sb / Sn) were prepared by cation substitution method and tested by cyclic voltammetry. Techniques as XRD and FT-IR were also used for characterizing materials. Was obtained up to 35 mA / g (Pt) peak current (redox ethanol) indicating the possibility of sepiolite technology development to use un proposed purpose. (author)

  16. 46 CFR 4.06-3 - Requirements for alcohol and drug testing following a serious marine incident.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Requirements for alcohol and drug testing following a... drug testing is conducted: (a) Alcohol testing. (1) Alcohol testing must be conducted on each... only if the alcohol testing meets all of the requirements of this part. (b) Drug testing. (1) Drug...

  17. Sodium removal by alcohol process: Basic tests and its application

    International Nuclear Information System (INIS)

    Nakai, S.; Yamamoto, S.; Akai, M.; Yatabe, T.

    1997-01-01

    We have various methods for sodium removal; an alcohol cleaning process, a steam cleaning process and a direct burning process. Sodium removal by the alcohol process has a lot of advantages, such as causing no alkali corrosion to steel, short processing time and easy operation. Therefore the alcohol process was selected for the 1MWt double wall tube straight type steam generator. We have already had some experiences of the alcohol process, while still needed to confirm the sodium removal rate in the crevice and to develop an on-line sodium concentration monitoring method in alcohol during sodium removal. We have conducted the small scale sodium removal test with flowing alcohol where the sodium removal rate in the crevice and the alcohol conductivity were measured as functions of sodium concentration in alcohol and alcohol temperature. The sodium removal of the DWTSG was conducted by the devised alcohol process safely and efficiently. The process hour was about 1 day. Visual inspection during dismantling of the DWTSG showed no evidence of any un-reacted sodium. (author)

  18. Estudo preliminar do potencial cariogênico de preparações doces da merenda escolar através do pH da saliva Preliminary study of cariogenic potential of sweet school meal preparations through saliva pH

    Directory of Open Access Journals (Sweden)

    Cristiane Pinheiro Lázaro

    1999-12-01

    Full Text Available Objetivou-se determinar a curva de pH da saliva após o consumo de preparações doces, relacionar as variáveis teor de glicídios e pH, e discutir dados sobre o uso de preparações doces na merenda escolar do município de Niterói, RJ, com diferentes teores de glicídios e diferentes consistências, com crianças em idade pré-escolar e escolar, atendidas no Departamento de Odontologia Clínica da Faculdade de Odontologia da Universidade Federal Fluminense. Para os testes, foram selecionadas 52 crianças eutróficas, sadias, sem uso de medicamentos que alterassem o fluxo e a composição da saliva e com baixo e alto risco de cárie. Neste grupo, 54% apresentavam idade de 7 a 10 anos. Foi medido o pH da saliva, com fitas indicadoras, antes e após o consumo destas preparações, em um intervalo de 10, 20, 40 e 60 minutos. O tratamento estatístico foi realizado através do "software" Epi Info e foram realizados os testes de Qui-Quadrado e "t" de Student. Nenhuma das curvas de pH da saliva, para todas as preparações testadas e grupos de risco atingiram valor de pH considerado crítico (5,3 - 5,5. As curvas de pH médio da saliva, para todas as preparações testadas, oscilaram em valores de pH mais elevados para o grupo de baixo risco de cárie e em valores mais baixos para o grupo de alto risco de cárie. As curvas de pH médio da saliva do grupo de baixo risco demonstraram queda mais lenta e recuperação mais tardia, enquanto que no grupo de alto risco a queda e a recuperação do pH foram mais imediatas. A consistência das preparações foi preponderante sobre o teor de glicídios. Recomenda-se que o planejamento da merenda escolar leve em consideração o efeito da consistência das preparações doces servidas.The aim of this study was to establish the saliva pH curve in response to sweet foods, with different carbohydrate rates and different consistencies, frequently found in the school meal program in Niterói, Rio de Janeiro

  19. Hepatitis B virus DNA in saliva from children with chronic hepatitis B infection: implications for saliva as a potential mode of horizontal transmission

    DEFF Research Database (Denmark)

    Heiberg, Ida Louise; Hoegh, Mette; Ladelund, Steen

    2010-01-01

    To explore the mechanism of horizontal transmission of hepatitis B virus (HBV) among children, we investigated the quantitative relationship between HBV in saliva and blood from 46 children with chronic hepatitis B. We found high levels of HBV DNA in saliva of HBeAg (+) children, suggesting saliva...... as a vehicle for horizontal transmission of HBV among children....

  20. Artificial saliva effect on toxic substances release from acrylic resins

    Directory of Open Access Journals (Sweden)

    Kostić Milena

    2015-01-01

    Full Text Available Background/Aim. Acrylic-based resins are intensively used in dentistry practice as restorative or denture-base materials. The purpose of this study was to analyze the surface structure of denture base resins and the amount of released potentially toxic substances (PTS immediately upon polymerization and incubation in different types of artificial saliva. Methods. Storage of acrylic samples in two models of artificial saliva were performed in a water bath at the temperature of 37 ± 1°C. Analysis of the surface structure of samples was carried out using scanning electronic microscopy analysis immediately after polymerization and after the 30-day incubation. The amounts of PTS per day, week and month extracts were measured using high-pressure liquid chromatography. Results. Surface design and amount of PTS in acrylic materials were different and depended on the types and duration of polymerization. The surfaces of tested acrylates became flatter after immersing in solutions of artificial saliva. The degree of acrylic materials release was not dependent on the applied model of artificial saliva. Conclusion. In order to improve biological features of acrylic resin materials, it was recommended that dentures lined with soft or hard coldpolymerized acrylates should be kept at least 1 to 7 days in water before being given to a patient. So, as to reach high degree of biocompatibility preparation of prosthetic restorations from heat-polymerized acrylate was unnecessary. [Projekat Ministarstva nauke Republike Srbije, br. 41017

  1. Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel.

    Science.gov (United States)

    Memarpour, Mahtab; Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak

    2018-01-01

    The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words: Pit and fissure sealant, Universal adhesive, Saliva.

  2. Rapid Detection of the Varicella Zoster Virus in Saliva

    Science.gov (United States)

    Pierson, Duane L.; Mehta, Satish K.; Cohrs, Randall J.; Gilden, Don H.; Harding, Robert E.

    2011-01-01

    Varicella zoster virus (VZV) causes chicken pox on first exposure (usually in children), and reactivates from latency causing shingles (usually in adults). Shingles can be extremely painful, causing nerve damage, organ damage, and blindness in some cases. The virus can be life-threatening in immune-compromised individuals. The virus is very difficult to culture for diagnosis, requiring a week or longer. This invention is a rapid test for VZV from a saliva sample and can be performed in a doctor s office. The kit is small, compact, and lightweight. Detec tion is sensitive, specific, and noninvasive (no needles); only a saliva sample is required. The test provides results in minutes. The entire test is performed in a closed system, with no exposure to infectious materials. The components are made mostly of inexpensive plastic injection molded parts, many of which can be purchased off the shelf and merely assembled. All biological waste is contained for fast, efficient disposal. This innovation was made possible because of discovery of a NASA scientists flight experiment showing the presence of VZV in saliva during high stress periods and disease. This finding enables clinicians to quickly screen patients for VZV and treat the ones that show positive results with antiviral medicines. This promotes a rapid recovery, easing of pain and symptoms, and reduces chances of complications from zoster. Screening of high-risk patients could be incorporated as part of a regular physical exam. These patients include the elderly, pregnant women, and immune-compromised individuals. In these patients, VZV can be a life-threatening disease. In both high- and low-risk patients, early detection and treatment with antiviral drugs can dramatically decrease or even eliminate the clinical manifestation of disease.

  3. Testing for drug and alcohol аbuse at the workplace

    Directory of Open Access Journals (Sweden)

    Zoran Kavrakovski

    2009-12-01

    Full Text Available Drug and alcohol abuse in the workplace represents a great risk to employee’s health and safety. More than 50% of the employees worldwide are related to easily accessible drug abuse, while 70% of the employees are related to alcohol abuse in the workplace. Tests for detecting drug and alcohol abuse in the workplace should be part of a new regulation, compulsory for all employees in the Republic of Macedonia. Implementing this sort of testing program should at the same time be a step towards devising particular solutions that shall bring about greater safety in the working environment. A key element in the implementation is to devise and establish an adequate policy that shall determine the risk factors within a working establishment which shall clearly express its position regarding drug and alcohol abuse during working hours. Along with the risk factors, the policy may also include the program for testing both, employees and the ones who are about to be employed, for drug and alcohol abuse. In order to implement this sort of test, it must be in accordance with the Occupational Safety and Health Act (Official gazette of the Republic of Macedonia, No 92/07, 2007 and a legal framework has to be defined, that shall regulate and solve numerous aspects of this issue, in order to fully implement the program for drug free working environment pursuant to the Declaration and the decrees of the United Nations General Assembly in 1998.

  4. Light-emitting device test systems

    Science.gov (United States)

    McCord, Mark; Brodie, Alan; George, James; Guan, Yu; Nyffenegger, Ralph

    2018-01-23

    Light-emitting devices, such as LEDs, are tested using a photometric unit. The photometric unit, which may be an integrating sphere, can measure flux, color, or other properties of the devices. The photometric unit may have a single port or both an inlet and outlet. Light loss through the port, inlet, or outlet can be reduced or calibrated for. These testing systems can provide increased reliability, improved throughput, and/or improved measurement accuracy.

  5. Facilitated saliva secretion and reduced oral inflammation by a novel artificial saliva system in the treatment of salivary hypofunction

    Directory of Open Access Journals (Sweden)

    Kang M

    2017-01-01

    Full Text Available Minkyung Kang,1 Hyounggeun Park,1 Joon-Ho Jun,1 Miwon Son,1 Myung Joo Kang2 1Pharmaceutical Product Research Laboratories, Dong-A ST Research Institute, Gyeonggi, 2Division of Pharmaceutical Sciences, College of Pharmacy, Dankook University, Cheonan, Chungnam, Korea Abstract: Saliva substitutes and/or lubricants are commonly employed to lessen dry mouth symptoms by stimulating and/or substituting for the secretion of saliva. In this study, a novel artificial saliva containing inorganic salts, including sodium chloride and potassium chloride, and bactericidal agents, including potassium thiocyanate and lactoperoxidase, was formulated in the form of a solution (DM-sol or gel (DM-gel. Those in vivo therapeutic efficacies were assessed in terms of saliva secretion and anti-inflammatory activity in rats and mice, respectively. Salivary secretion was promoted by mucosal application of DM-formulations in normal rats. In particular, DM-gel resulted in 2.5- and 1.9-fold greater salivary flow rates compared to normal saline and DM-sol, respectively. In an in vivo efficacy evaluation in diabetic mice with salivary hypofunction, repeated application of DM-formulations alleviated histopathological changes in the buccal mucosa in terms of atrophy and thinning of the epithelium, compared to vehicle, after 4 weeks. Moreover, the DM-sol and DM-gel were comparably effective for relieving periodontal gingivitis, reducing infiltration of inflammatory cells, and normalizing the neutrophil level in the gingival gingiva, after 4 weeks. Therefore, the novel artificial saliva is expected to facilitate salivary secretion and restore physiological conditions in the mouth of patients with salivary hypofunction. Keywords: saliva substitute, carbopol gel, hypothiocyanite–hydrogen peroxide mixture, antimicrobial activity, diabetic rats

  6. Appearance test device

    International Nuclear Information System (INIS)

    Watanabe, Tadao.

    1995-01-01

    The device of the present invention photographs glass solidification products of high level radioactive wastes by a camera to inspect the state for the surface of the glass solidification products. Namely, illumination light is irradiated to the surface of a material to be tested containing radioactive substances to photograph the surface to be tested and the photographed images are displayed. A photographing unit enhousing an illumination light source and the camera for photographing the surface to be detected is movable in the longitudinal direction of the object to be detected. A first reflector is disposed for reflecting the illumination light from the light source in a horizontal direction intersecting the longitudinal direction described above and reflecting the reflection light from the object to be tested to the camera. A second reflector is disposed to a position opposing to the end face of the object to be detected for entering the illumination light from the first reflector to the end face of the object to be tested and reflecting the reflection light from the end face of the object to be detected to the first reflector. In a device thus composed, the upper and lower end faces of the object to be tested can be illuminated and photographed without facing the photographing unit to the object to be inspected. (I.S.)

  7. Contribution of targeted saliva screening for congenital CMV-related hearing loss in newborns who fail hearing screening.

    Science.gov (United States)

    Ari-Even Roth, Daphne; Lubin, Daniel; Kuint, Jacob; Teperberg-Oikawa, Michal; Mendelson, Ella; Strauss, Tzipora; Barkai, Galia

    2017-11-01

    We previously reported a 2.2% rate of infants born with sensorineural hearing loss (SNHL) due to congenital cytomegalovirus (cCMV) infection identified by universal neonatal screen for cCMV using saliva. To evaluate the contribution of targeted saliva screening for cCMV to the detection of infants born with cCMV-related SNHL who failed universal newborn hearing screening (UNHS). We retrospectively reviewed the audiological and medical records of infants who failed UNHS and were tested for cCMV using saliva sample prior to discharge at Sheba Medical Center between 2014 and 2015. Positive cases were confirmed by urine sample. Two hundred (1%) of the 19 830 infants tested during the study period failed in-hospital hearing screening. A saliva specimen was obtained prior to discharge in 187 infants (93.5% of those who failed UNHS). In 178 infants saliva testing was performed at ≤21 days of chronological age and yielded results. cCMV infection was identified in 4/178 tested infants (2.25%, 95% CI 0.8% to 5.3%), of whom three were diagnosed with SNHL (1.7%, 95% CI 0.5% to 4.4%) and offered antiviral treatment. Two of the tested infants (1.12%, 95% CI 0.2% to 3.6%) were diagnosed with cCMV solely due to failure in UNHS. Occult central nervous system (CNS) symptoms of cCMV infection were detected in 2/4 infants following targeted investigation. Targeted cCMV screening in newborns who failed UNHS contributed to the early detection of infants born with cCMV-related isolated SNHL or with occult CNS symptoms who could potentially benefit from antiviral treatment. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Psychiatric disorders among individuals who drive after the recent use of alcohol and drugs.

    Science.gov (United States)

    Faller, Sibele; Webster, J Matthew; Leukefeld, Carl G; Bumaguin, Daniela Benzano; Duarte, Paulina do Carmo Arruda Vieira; De Boni, Raquel; Pechansky, Flavio

    2012-10-01

    This cross-sectional study assessed the prevalence of psychiatric disorders among drivers , as well as the association between recent alcohol and drug use and psychiatric diagnoses using telephone interviews. Drivers (n = 1,134) included in a roadside survey from 25 Brazilian state capitals were given a breathalyzer test, and their saliva was tested for psychoactive drugs. A telephone interview was conducted to perform psychiatric disorder evaluations using the MINI. This association was analyzed with a Poisson regression model. The prevalence of any psychiatric disorder was 40.5% among drivers with recent alcohol or drug use, compared with 12.9% among the other drivers. Alcohol/drug-positive drivers reported a higher prevalence of depression (19.4%), mania (6.5%), hypomania (5.4%), post-traumatic stress disorder (8.6%), antisocial personality (7.8%), and substance/alcohol abuse or dependence (48.1%) compared with other drivers (3.5, 2.5, 2.1, 0.5, 1.3 and 18.3% [p < 0.001], respectively). Drivers with recent alcohol or drug use were 2.5 times more likely to have a psychiatric diagnosis (CI: 1.8-3.6, p < 0.001). This is the first study in a low-/middle-income country to evaluate psychiatric disorders in drivers with recent alcohol or drug using telephone interviews. Psychiatric disorders were found to be associated with drug and alcohol use. This type of epidemiological information for curtailing related driving problems, as these psychiatric conditions are diagnosable. The results of this study can aid in the design of interventions, treatment programs and focused psychiatric evaluations, both in Brazil and abroad.

  9. 49 CFR 655.61 - Action when an employee has a verified positive drug test result or has a confirmed alcohol test...

    Science.gov (United States)

    2010-10-01

    ... drug test result or has a confirmed alcohol test result of 0.04 or greater, or refuses to submit to a... drug test result or has a confirmed alcohol test result of 0.04 or greater, or refuses to submit to a... performing a safety-sensitive function. (3) If an employee refuses to submit to a drug or alcohol test...

  10. Fluoride in dental biofilm and saliva

    DEFF Research Database (Denmark)

    Larsen, Line Staun

    Dette ph.d.-projekt bidrager med ny viden om fordelingen af fluorid i dental biofilm og saliva. For at udforske koncentrationen af fluorid i naturlig (in vivo) biofilmvæske, biofilmsediment og i saliva, blev der udført to meget forskellige kliniske studier. Resultaterne fra tværsnitsstudiet (Studie...... I), hos en stor gruppe mennesker (n=42) der konsulterede en tandklinik for behandling, bekræfter tidligere viden, at der findes en naturlig biologisk variation i fluoridkoncentrationerne i biofilm fra forskellige intra-orale regioner samt mellem biofilmvæske, biofilmsediment og saliva...... fluoridkoncentrationer i underkæbefronten, intermediære koncentrationer i alle tre overkæberegioner og de laveste koncentrationer i underkæbemolarregionerne. Begge studier viser at biofilmsedimentet indeholder størstedelen af fluorid i biofilm. Set i et bredere perspektiv viser fundene at der er et omvendt forhold...

  11. Trace element measurement in Saliva by NAA and PIXE techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hamidian, M.R.; Vahid Golpayegani, M.; Shojai, S. (Shahid Beheshti Medical Science Univ., Shemiran, Tehran (Iran, Islamic Republic of))

    1993-01-01

    The activity of salivary glands and the chemical and physical properties of saliva, especially in some illnesses in which the activity of salivary glands and the chemical and physical properties alter, sometimes have severe effects on sedimentation and tooth decay. Long-standing investigations have shown the relationship between salivary gland activity and saliva composition in dental carries. Many modern techniques have been employed to measure important elements in saliva. The major elements in saliva include sodium, potassium, calcium, magnesium, chlorine, phosphorus, iodine, and fluorine. It should be pointed out that the amount of minerals changes when the diet changes. The major constituent of saliva is water with a density of 1.007 g/cm[sup 3] in which 0.6% is solid, 0.3% organic material and 0.3% inorganic material. In addition to other effects, the acidity (pH) of saliva has a strong effect on tooth sedimentation. Type of work, degree of stress, and mental condition affect salivary gland activity. When the acidity of salivary fluid in the mouth and consequently over the teeth drops, sedimentation increases. In this paper, the results of trace element measurement in saliva are presented.

  12. Unreliable alcohol testing in a shipping safety programme.

    Science.gov (United States)

    Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn

    2009-08-10

    Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.

  13. Primary care validation of a single-question alcohol screening test.

    Science.gov (United States)

    Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard

    2009-07-01

    Unhealthy alcohol use is prevalent but under-diagnosed in primary care settings. To validate, in primary care, a single-item screening test for unhealthy alcohol use recommended by the National Institute on Alcohol Abuse and Alcoholism (NIAAA). Cross-sectional study. Adult English-speaking patients recruited from primary care waiting rooms. Participants were asked the single screening question, “How many times in the past year have you had X or more drinks in a day?”, where X is 5 for men and 4 for women, and a response of 1 or greater [corrected] is considered positive. Unhealthy alcohol use was defined as the presence of an alcohol use disorder, as determined by a standardized diagnostic interview, or risky consumption, as determined using a validated 30-day calendar method. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single-question screen was 81.8% sensitive (95% confidence interval (CI) 72.5% to 88.5%) and 79.3% specific (95% CI 73.1% to 84.4%) for the detection of unhealthy alcohol use. It was slightly more sensitive (87.9%, 95% CI 72.7% to 95.2%) but was less specific (66.8%, 95% CI 60.8% to 72.3%) for the detection of a current alcohol use disorder. Test characteristics were similar to that of a commonly used three-item screen, and were affected very little by subject demographic characteristics. The single screening question recommended by the NIAAA accurately identified unhealthy alcohol use in this sample of primary care patients. These findings support the use of this brief screen in primary care.

  14. Hacking and penetration testing with low power devices

    CERN Document Server

    Polstra, Philip

    2014-01-01

    Hacking and Penetration Testing with Low Power Devices shows you how to perform penetration tests using small, low-powered devices that are easily hidden and may be battery-powered. It shows how to use an army of devices, costing less than you might spend on a laptop, from distances of a mile or more. Hacking and Penetration Testing with Low Power Devices shows how to use devices running a version of The Deck, a full-featured penetration testing and forensics Linux distribution, and can run for days or weeks on batteries due to their low power consumption. Author Philip Polstra shows how to

  15. Radioimmunological method for determination of cortisol in saliva

    International Nuclear Information System (INIS)

    Maleeva, A.; Mileva, Zh.; Kekhajova, M.

    1989-01-01

    A method was developed for determination of cortisol in saliva after being previously extracted with dichlormethane. Cortisol concentration in saliva of 19 subjects was determined by this method. The saliva cortisol levels were compared with those of blood plasma. No statistically significant difference was found. The method finds acceptance primarily when frequent measurements of cortisol level are neccessary as a screening technique and when strongly abnormally high levels should be differentiated from the normal ones: in this latter case determination of plasma cortisol is mandatory. 5 tabs., 8 refs

  16. Clinical trial participant characteristics and saliva and DNA metrics

    Directory of Open Access Journals (Sweden)

    Richards Julie

    2009-10-01

    Full Text Available Abstract Background Clinical trial and epidemiological studies need high quality biospecimens from a representative sample of participants to investigate genetic influences on treatment response and disease. Obtaining blood biospecimens presents logistical and financial challenges. As a result, saliva biospecimen collection is becoming more frequent because of the ease of collection and lower cost. This article describes an assessment of saliva biospecimen samples collected through the mail, trial participant demographic and behavioral characteristics, and their association with saliva and DNA quantity and quality. Methods Saliva biospecimens were collected using the Oragene® DNA Self-Collection Kits from participants in a National Cancer Institute funded smoking cessation trial. Saliva biospecimens from 565 individuals were visually inspected for clarity prior to and after DNA extraction. DNA samples were then quantified by UV absorbance, PicoGreen®, and qPCR. Genotyping was performed on 11 SNPs using TaqMan® SNP assays and two VNTR assays. Univariate, correlation, and analysis of variance analyses were conducted to observe the relationship between saliva sample and participant characteristics. Results The biospecimen kit return rate was 58.5% among those invited to participate (n = 967 and 47.1% among all possible COMPASS participants (n = 1202. Significant gender differences were observed with males providing larger saliva volume (4.7 vs. 4.5 ml, p = 0.019, samples that were more likely to be judged as cloudy (39.5% vs. 24.9%, p 0.21, P Conclusion Findings from this study show that demographic and behavioral characteristics of smoking cessation trial participants have significant associations with saliva and DNA metrics, but not with the performance of TaqMan® SNP or VNTR genotyping assays. Trial registration COMPASS; registered as NCT00301145 at clinicaltrials.gov.

  17. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    OpenAIRE

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea

    2013-01-01

    Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons...

  18. 10 CFR 26.31 - Drug and alcohol testing.

    Science.gov (United States)

    2010-01-01

    ... Transportation Workplace Drug and Alcohol Testing Programs” (65 FR 41944; August 9, 2001) to collect specimens... could be construed as a potential conflict of interest. The forensic toxicologist may not be an employee... or drug metabolites in Federal workplace drug testing programs and the licensee or other entity...

  19. Saliva as a future potential predictor for various periodontal diseases

    Directory of Open Access Journals (Sweden)

    Zahreni Hamzah

    2011-06-01

    Full Text Available Background: There are many diagnostic biomarkers have been found in saliva. Saliva contains a wide variety of proteins, including bacteria and products, enzymes, inflammatory mediators and host response modifiers, products of tissue breakdown. Purpose: The purpose of the study was studied current development of diagnostic biomarkers in saliva that will lead to the development of simple and accurate diagnostic tools for periodental disease. Reviews: Specifically, the salivary biomarkers divided for three aspects of periodontitis i.e. inflammation, collagen degradation and bone turnover, correlated with clinical features of periodontal disease. The diagnostic biomarkers is in saliva, such as enzyme, immunoglobulin, cytokines, bacteria and bacterial products, hormones. For the past two decades, oral health researchers have been developing salivary diagnostic tools to monitor oral diseases. Conclusion: The indicators of acute periodontitis can detect with ß-glucuronidase and AST, IL-1β, and MMP-8, whereas indicators for chronic periodontitis can detect with ALP. The indicators for collagen degradation and bone turnover suggest ICTP, fibronectin fragments, and osteonectin. The indicators of severity of periodontitis especially can be predict by B. forsythus.Latar belakang: Banyak biomarker telah ditemukan dalam saliva. Saliva terdiri dari berbagai protein unik meliputi bakteri dan produk bakteri, enzim, mediator inflamasi dan modifikasi respon host (immunoglobulin, sitokin, produk kerusakan jaringan (telopeptida kolagen, osteokalsin, proteoglikan, fragmen fibronectin. Tujuan: Mengkaji biomarker dalam saliva untuk pengembangan metode diagnostik sederhana dan akurat untuk penyakit periodontal. Tinjauan Pustaka: Secara khusus, biomarker saliva pada periodontitis dibagi dalam tiga aspek yaitu inflamasi, dan degradasi kolagen serta pergantian tulang. Biomarker diagnostik dalam saliva, meliputi enzim, imunoglobulin, sitokin, bakteri dan produk

  20. 75 FR 38422 - Procedures for Transportation Workplace Drug and Alcohol Testing Programs

    Science.gov (United States)

    2010-07-02

    ... 2105-AD84 Procedures for Transportation Workplace Drug and Alcohol Testing Programs AGENCY: Office of..., 2011. DATES: This rule is effective July 2, 2010. FOR FURTHER INFORMATION CONTACT: For program issues... Federal Regulations, as follows: PART 40--PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING...

  1. Saliva-catalyzed hydrolysis of a ketobemidone ester prodrug

    DEFF Research Database (Denmark)

    Hansen, L.B.; Christrup, Lona Louring; Bundgaard, H.

    1992-01-01

    Saliva enzyme-catalysed hydrolysis of ester prodrugs or drugs containing sensitive ester groups may be a limiting factor for the buccal absorption of such compounds. Using the isopropyl carbonate ester of ketobemidone as a model substance of a hydrolysis-sensitive prodrug the esterase activity...... of human saliva has been characterized as a function of various factors. The esterase activity was found to decrease rapidly upon storage of the saliva at 37°C. The activity increased with increasing pH in the range 4.5-7.4 and with increasing salivation flow rate up to a rate of 0.9 ml min. Under resting...... conditions, the flow rate was about 0.2 ml min which implied a greatly decreased esterase activity. The activity was highest after fasting and decreased after intake of a meal. The intraindividual variation in the saliva esterase activity was small whereas a larger interindividual variation was found....

  2. Noninvasive Biomonitoring Approaches to Determine Dosimetry and Risk Following Acute Chemical Exposure: Analysis of Lead or Organophosphate Insecticide in Saliva

    International Nuclear Information System (INIS)

    Timchalk, Chuck; Poet, Torka S.; Kousba, Ahmed A.; Campbell, James A.; Lin, Yuehe

    2004-01-01

    There is a need to develop approaches for assessing risk associated with acute exposures to a broad-range of chemical agents and to rapidly determine the potential implications to human health. Non-invasive biomonitoring approaches are being developed using reliable portable analytical systems to quantitate dosimetry utilizing readily obtainable body fluids, such as saliva. Saliva has been used to evaluate a broad range of biomarkers, drugs, and environmental contaminants including heavy metals and pesticides. To advance the application of non-invasive biomonitoring a microfluidic/ electrochemical device has also been developed for the analysis of lead (Pb), using square wave anodic stripping voltammetry. The system demonstrates a linear response over a broad concentration range (1 2000 ppb) and is capable of quantitating saliva Pb in rats orally administered acute doses of Pb-acetate. Appropriate pharmacokinetic analyses have been used to quantitate systemic dosimetry based on determination of saliva Pb concentrations. In addition, saliva has recently been used to quantitate dosimetry following exposure to the organophosphate insecticide chlorpyrifos in a rodent model system by measuring the major metabolite, trichloropyridinol, and saliva cholinesterase inhibition following acute exposures. These results suggest that technology developed for non-invasive biomonitoring can provide a sensitive, and portable analytical tool capable of assessing exposure and risk in real-time. By coupling these non-invasive technologies with pharmacokinetic modeling it is feasible to rapidly quantitate acute exposure to a broad range of chemical agents. In summary, it is envisioned that once fully developed, these monitoring and modeling approaches will be useful for accessing acute exposure and health risk

  3. Tobacco smoking, alcohol consumption and gastro-oesophageal reflux disease.

    Science.gov (United States)

    Ness-Jensen, Eivind; Lagergren, Jesper

    2017-10-01

    Gastro-oesophageal reflux disease (GORD) develops when reflux of gastric content causes troublesome symptoms or complications. The main symptoms are heartburn and acid regurgitation and complications include oesophagitis, strictures, Barrett's oesophagus and oesophageal adenocarcinoma. In addition to hereditary influence, GORD is associated with lifestyle factors, mainly obesity. Tobacco smoking is regarded as an aetiological factor of GORD, while alcohol consumption is considered a triggering factor of reflux episodes and not a causal factor. Yet, both tobacco smoking and alcohol consumption can reduce the lower oesophageal sphincter pressure, facilitating reflux. In addition, tobacco smoking reduces the production of saliva rich in bicarbonate, which is important for buffering and clearance of acid in the oesophagus. Alcohol also has a direct noxious effect on the oesophageal mucosa, which predisposes to acidic injury. Tobacco smoking cessation reduces the risk of GORD symptoms and avoidance of alcohol is encouraged in individuals where alcohol consumption triggers reflux. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Effect of saliva contamination and artificial aging on different primer/cement systems bonded to zirconia.

    Science.gov (United States)

    Pitta, João; Branco, Teresa C; Portugal, Jaime

    2018-05-01

    Saliva contamination has been shown to decrease bonding to zirconia. Adopting a less contamination-sensitive cement system may be an alternative to decontamination. The purpose of this in vitro study was to assess the ability of different primer/cement systems to promote a durable bond to zirconia after saliva contamination. Zirconia blocks (Lava Plus) (N=320) were airborne-particle abraded (50 μm Al 2 O 3 ) and divided into 32 experimental groups (n=10) according to the variables in the study: saliva contamination; primer/cement system (Panavia SA [PSA]; RelyX Unicem 2 [RU2]; Bifix SE [BSE]; Panavia F2.0 [PF2]; Scotchbond Universal + RelyX Ultimate [SBU+RXU]; Futurabond M+ + Bifix QM [FBM+BQM]; All-Bond Universal + Duo-link [ABU+DL]; Z-Prime Plus + Duo-link [ZPP+DL]; and aging period (72 hours; 30 days with 10 000 thermocycles at 5°C to 55°C). After half of the blocks had been contaminated with fresh human saliva for 10 minutes, rinsed with water, and air-dried, each primer/cement was applied. Polymerized composite resin disks were then placed over the cement, and the resin cement was light-polymerized for 20 seconds each at 2 opposite margins. After the aging time, the specimens were tested in shear (1 mm/min). The failure mode was classified as adhesive, cohesive, or mixed. Statistical analysis of the shear bond strength (SBS) data was performed with ANOVA followed by Tukey honest significant difference post hoc tests. Chi-square tests were used to analyze the failure mode data (α=.05). The mean SBS ranged between 4.2 and 34.5 MPa. Shear bond strength was influenced (Pcontamination, aging time). SBU+RXU and FBM+BQM showed a higher mean SBS than those of the other experimental groups (Pcontamination (P>.05). Failure was predominantly classified as adhesive. In general, saliva contamination and aging decreased bonding efficacy. Two systems, combining an application of a universal adhesive and a resin cement (SBU+RXU and FBM+BQM) were not affected by

  5. Understanding of xerostomia and strategies for the development of artificial saliva.

    Science.gov (United States)

    Kho, Hong-Seop

    2014-01-01

    Xerostomia is becoming a major issue in dental and medical clinics with an increase of aged population. Medication is the most common etiology of xerostomia, while the most severe xerostomia generally occurs in patients with a history of head and neck radiotherapy. Xerostomic patients usually suffer from diminished quality of life due to various symptoms and complications. Decreased salivary output is a definite objective sign, but oral mucosal wetness is a more reliable factor for the evaluation of xerostomia. At present there are no effective therapeutic methods for the treatment of xerostomia. Sialogogues may have problematic side effects and their therapeutic effects last only brief duration. Artificial saliva typically does not produce satisfactory results in therapeutic efficacy. Therefore, further research and development of better therapeutic modalities are necessary. The basic concept for the development of ideal and functional artificial saliva is the mimicry of natural human saliva. We need proper candidate molecules and antimicrobial supplements to simulate the rheological and biological properties of human saliva. We also need better understanding of the interactions between the ingredients of artificial saliva themselves and between the ingredients and components of human saliva both in solution and on surface phases. In addition, we need accepted measures to evaluate the efficacy of artificial saliva. In conclusion, for the development of ideal artificial saliva, research based on the understanding of pathophysiology of xerostomia and knowledge about rheological and biological functions of human saliva are necessary.

  6. Periodontitis diagnostics using resonance Raman spectroscopy on saliva

    Science.gov (United States)

    Gonchukov, S.; Sukhinina, A.; Bakhmutov, D.; Biryukova, T.; Tsvetkov, M.; Bagratashvily, V.

    2013-07-01

    In view of its wealth of molecular information, Raman spectroscopy has been the subject of active biomedical research. The aim of this work is Raman spectroscopy (RS) application for the determination of molecular biomarkers in saliva with the objective of early periodontitis detection. As was shown in our previous study, carotenoids contained in saliva can be molecular fingerprint information for the periodontitis level. It is shown here that the carotenoid RS lines at wavenumbers of 1156 and 1524 cm-1 can be easily detected and serve as reliable biomarkers of periodontitis using resonance Raman spectroscopy of dry saliva.

  7. Periodontitis diagnostics using resonance Raman spectroscopy on saliva

    International Nuclear Information System (INIS)

    Gonchukov, S; Sukhinina, A; Bakhmutov, D; Biryukova, T; Tsvetkov, M; Bagratashvily, V

    2013-01-01

    In view of its wealth of molecular information, Raman spectroscopy has been the subject of active biomedical research. The aim of this work is Raman spectroscopy (RS) application for the determination of molecular biomarkers in saliva with the objective of early periodontitis detection. As was shown in our previous study, carotenoids contained in saliva can be molecular fingerprint information for the periodontitis level. It is shown here that the carotenoid RS lines at wavenumbers of 1156 and 1524 cm −1 can be easily detected and serve as reliable biomarkers of periodontitis using resonance Raman spectroscopy of dry saliva. (letter)

  8. Results from the 2013 drug and alcohol testing survey.

    Science.gov (United States)

    2015-12-01

    This report summarizes the results of the 2013 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses (CDLs) that test positive fo...

  9. Results from the 2008 Drug and Alcohol Testing Survey

    Science.gov (United States)

    2010-01-01

    This report summarizes the results of the 2008 Federal Motor Carrier Safety Administration Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses who test positive for controlled sub...

  10. Inorganic component of saliva during fasting and after fast break

    OpenAIRE

    Samad, Rasmidar

    2016-01-01

    Oral health is closely related to salivary components. Saliva consists of water, inorganic and organic materials. Fasting changes one???s meal and drinking time that in turn can affect the environment in oral cavity, including inorganic componenet of saliva. The purpose of this study is to determine the inorganic component of saliva during fasting and after fast break.

  11. Performance Tests for Bubble Blockage Device

    International Nuclear Information System (INIS)

    Ha, Kwang Soon; Wi, Kyung Jin; Park, Rae Joon; Wan, Han Seong

    2014-01-01

    Postulated severe core damage accidents have a high threat risk for the safety of human health and jeopardize the environment. Versatile measures have been suggested and applied to mitigate severe accidents in nuclear power plants. To improve the thermal margin for the severe accident measures in high-power reactors, engineered corium cooling systems involving boiling-induced two-phase natural circulation have been proposed for decay heat removal. A boiling-induced natural circulation flow is generated in a coolant path between a hot vessel wall and cold coolant reservoir. In general, it is possible for some bubbles to be entrained in the natural circulation loop. If some bubbles entrain in the liquid phase flow passage, flow instability may occur, that is, the natural circulation mass flow rate may be oscillated. A new device to block the entraining bubbles is proposed and verified using air-water test loop. To avoid bubbles entrained in the natural circulation flow loop, a new device was proposed and verified using an air-water test loop. The air injection and liquid circulation loop was prepared, and the tests for the bubble blockage devices were performed by varying the geometry and shape of the devices. The performance of the bubble blockage device was more effective as the area ratio of the inlet to the down-comer increased, and the device height decreased. If the device has a rim to generate a vortex zone, the bubbles will be most effectively blocked

  12. Penetration testing using mobile devices

    CSIR Research Space (South Africa)

    Shelembe, S

    2012-10-01

    Full Text Available et.al, 2006) ? An attempt to compromise the security of the mechanism undergoing the test, it can be host or network based (Fiocca, 2009) Difference: pen-testing and hacking is permission Its purpose is to find system vulnerabilities ? CSIR 2012... is not enough, cell-phones can hack too ? Pocket sized device is more convenient, since it is easy to carry around at anytime ? A power plug is not innocent, need to look for activity other than just traditional PCs / devices ? CSIR 2012 Slide 6 Mobile...

  13. Saliva tannin interactions.

    Science.gov (United States)

    Prinz, J F; Lucas, P W

    2000-11-01

    Many plant foods contain tannins, compounds that bind proteins, such as mammalian enzymes. Although described as tasteless, tannins can be detected orally by their astringency. However, the actual mechanism of oral detection and the effect of tannins on mastication and swallowing have been little investigated. Here, we show from in vitro tests that tannic acid, a common standard in tests used to detect tannins, significantly reduces the lubricating qualities of human saliva both by decreasing its viscosity and increasing friction, both factors lending support to the notion that astringency is a tactile phenomenon. From the literature, it is clear that this effect depends on the presence of salivary proline-rich proteins (PRP). In a mammalian context, ingestion of tannin-rich foods in a species with salivary PRP will be signalled by interference with bolus formation during mastication while the increase in friction may also be detectable and lead to increased tooth wear if the signal is ignored. In a human context, cross-cultural preferences for tannin-rich beverages such as tea, coffee and red wine at the end of meals may be explained by reduction in adhesion of food particles to the oral mucosa allowing their rapid oral clearance.

  14. 49 CFR 40.341 - Must service agents comply with DOT drug and alcohol testing requirements?

    Science.gov (United States)

    2010-10-01

    ... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Roles and Responsibilities of Service Agents § 40.341 Must service agents comply with DOT drug and alcohol testing... requirements of this part and the DOT agency drug and alcohol testing regulations. (b) If you do not comply...

  15. Microbial community profiling of human saliva using shotgun metagenomic sequencing.

    Directory of Open Access Journals (Sweden)

    Nur A Hasan

    Full Text Available Human saliva is clinically informative of both oral and general health. Since next generation shotgun sequencing (NGS is now widely used to identify and quantify bacteria, we investigated the bacterial flora of saliva microbiomes of two healthy volunteers and five datasets from the Human Microbiome Project, along with a control dataset containing short NGS reads from bacterial species representative of the bacterial flora of human saliva. GENIUS, a system designed to identify and quantify bacterial species using unassembled short NGS reads was used to identify the bacterial species comprising the microbiomes of the saliva samples and datasets. Results, achieved within minutes and at greater than 90% accuracy, showed more than 175 bacterial species comprised the bacterial flora of human saliva, including bacteria known to be commensal human flora but also Haemophilus influenzae, Neisseria meningitidis, Streptococcus pneumoniae, and Gamma proteobacteria. Basic Local Alignment Search Tool (BLASTn analysis in parallel, reported ca. five times more species than those actually comprising the in silico sample. Both GENIUS and BLAST analyses of saliva samples identified major genera comprising the bacterial flora of saliva, but GENIUS provided a more precise description of species composition, identifying to strain in most cases and delivered results at least 10,000 times faster. Therefore, GENIUS offers a facile and accurate system for identification and quantification of bacterial species and/or strains in metagenomic samples.

  16. Using the false memory paradigm to test two key elements of alcohol expectancy theory.

    Science.gov (United States)

    Reich, Richard R; Goldman, Mark S; Noll, Jane A

    2004-05-01

    Two key aspects of alcohol expectancy theory--(a) that memories about alcohol effects are stored as relatively cohesive templates of information and (b) that these templates are automatically activated in alcohol-related contexts--were tested using the Deese-Roediger- McDermott false memory paradigm. Alcohol expectancy adjectives were studied, and false memory for expectancy target words was tested in neutral and alcohol contexts. Results indicated that in the alcohol context heavier drinkers showed more false memory for alcohol expectancy words than they did in a neutral context. Differences were not found for lighter drinkers. These results were consistent with alcohol expectancy theory, which was then compared with various forms of association theory in explaining these results and larger issues in the addiction field. ((c) 2004 APA, all rights reserved)

  17. INFRARED STUDIES OF HUMAN SALIVA. IDENTIFICATION OF A FACTOR IN HUMAN SALIVA PRODUCING AN INFRARED ABSORBANCE MAXIMUM AT 4.9 MICRONS

    Science.gov (United States)

    An absorption maximum was observed at 4.9 microns in infrared spectra of human parotid saliva. The factor causing this absorbance was found to be a...nitrate, and heat stability. Thiocyanate was then determined in 16 parotid saliva samples by a spectrophotometric method, which involved formation of

  18. Small intestinal malabsorption in chronic alcoholism: a retrospective study of alcoholic patients by the ¹⁴C-D-xylose breath test.

    Science.gov (United States)

    Hope, Håvar; Skar, Viggo; Sandstad, Olav; Husebye, Einar; Medhus, Asle W

    2012-04-01

    The ¹⁴C-D-xylose breath test was used at Ullevål University Hospital in the period from 1986 TO 1995 for malabsorption testing. The objective of this retrospective study was to reveal whether patients with chronic alcoholism may have intestinal malabsorption. The consecutive ¹⁴C-D-xylose breath test database was reviewed and patients with the diagnosis of chronic alcoholism were identified. ¹⁴C-D-xylose breath test results of the alcoholic patients were compared with the results of untreated celiac patients and patient and healthy controls. In the ¹⁴C-D-xylose breath test, ¹⁴C-D-xylose was dissolved in water and given orally after overnight fast. Breath samples were taken at 30-min intervals for 210 min, and ¹⁴CO₂ : ¹²CO₂ ratios were calculated for each time point, presenting a time curve for ¹⁴C-D-xylose absorption. Urine was collected after 210 min and the fraction of the total d-xylose passed was calculated (U%). ¹⁴CO₂ in breath and ¹⁴C-D-xylose in urine were analyzed using liquid scintillation. Both breath and urine analysis revealed a pattern of malabsorption in alcoholics comparable with untreated celiac patients, with significantly reduced absorption of d-xylose compared with patient and healthy controls. Alcoholic patients have a significantly reduced ¹⁴C-D-xylose absorption, comparable with untreated celiac patients. This indicates a reduced intestinal function in chronic alcoholism.

  19. 49 CFR 40.321 - What is the general confidentiality rule for drug and alcohol test information?

    Science.gov (United States)

    2010-10-01

    ... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Confidentiality and Release of Information § 40.321 What is the general confidentiality rule for drug and alcohol test... DOT drug or alcohol testing process, you are prohibited from releasing individual test results or...

  20. The Effect of Canal Contamination with Saliva on Apical Sealing

    Directory of Open Access Journals (Sweden)

    S Sabaghi

    2014-08-01

    Full Text Available Introduction: Root canal obturation aims at sealing the root canal system to prevent re-contamination of canal and periapical space. Presence of moisture in canal before obturation may posit a negative effect on the quality of canal sealing. Therefore, this study was conducted to investigate the effect of canal contamination with saliva on apical microleakage. Methods: In this laboratory study, 58 human uni-root teeth were cleaned and shaped for obturation with gutta percha and sealer AH26. In the case group, specimens were contaminated with human saliva immediately before obturation, whereas the teeth in the control group were kept dry. All canals were filled by lateral condensation technique. Moreover, the teeth were placed in methylene blue dye for 3 days. Dye penetration was measured using a stereomicrosope. As a matter of fact, the study data were analyzed via utilizing t-test. Results: A significant difference was found between the two groups in regard with the apical leakage(P<0.001. The microleakage mean of dye in the dry group was 3/48mm, whereas it was 6/36mm in the saliva contaminated group. Conclusion: The study findings revealed that complete drying of canal can improve apical sealing.

  1. The association between saliva control, silent saliva penetration, aspiration, and videofluoroscopic findings in Parkinson's disease patients

    Science.gov (United States)

    Rajaei, Ali; Ashtari, Fereshteh; Azargoon, Seyed Abolfazl; Chitsaz, Ahmad; Nilforoush, Mohammad Hussein; Taheri, Masoud; Sadeghi, Saba

    2015-01-01

    Background: Dysphagia is a common disorder among patients with Parkinson's disease (PD). It occurs in up to 80% of all (PD) patients during the early stages of the disease and up to 95% in the advanced stages; but professionals may not hear from the patients about dysphagia symptoms until these symptoms reach an advanced stage and lead to medical complications. Materials and Methods: Thirty-three PD patients (mean age 66.09 ± 9.4 years; 24 men, nine women) participated in this study at our Neurology Institute, between April 20, 2013, and October 26, 2013. They were asked two questions; one about saliva control and the other about silent saliva penetration and aspiration. Next, they underwent the videofluoroscopic swallowing study (VFSS). Results: The Pearson Correlation coefficient between the Penetration–Aspiration Scale (PAS) scores and question 1 scores was 0.48 (P < 0.05, =0.25), and there was a significant correlation between the PAS scores and question 2 scores, and also question 1 scores + question 2 scores (r = 0.589, P < 0.05, =0 and r = 0589, P < 0.05, =0). Conclusions: This study showed a significant correlation between the questions about saliva control, silent saliva penetration, and aspiration, and laryngeal penetration and aspiration during VFSS. Therefore, by using these two questions, the potential silent laryngeal penetration and aspiration during meals could be detected before it led to aspiration pneumonia. Taking the benefit of these questions, as a part of the swallowing assessment of PD patients, is recommended. PMID:26261810

  2. Factors determining the passage of drugs from blood into saliva.

    Science.gov (United States)

    Stephen, K W; McCrossan, J; Mackenzie, D; Macfarlane, C B; Speirs, C F

    1980-01-01

    1. Following single oral dosing of ampicillin, cephalexin, tetracycline, erythromycin estolate, clindamycin and rifampicin to six normal volunteers, antibacterial activity was measured at 1, 3 and 6 h in serum, gingival fluid and minor gland saliva from all subjects and in parotid and submandiabular saliva from three. 2. pH values of all gingival fluid and saliva specimens were noted. 3. Partition coefficients between n-octanol and water were measured for erythromycin, clindamycin and rifampicin. Published data were used for ampicillin, cephalexin and tetracycline. 4. All antibiotics, but particularly rifampicin, were detected in gingival fluid. Only rifampicin and to a lesser degree, clindamycin were present in the other salivary constituents. 5. In studies of secretion of drugs in saliva, both the physico-chemical characteristics of the drugs and the physiological differences between individual salivary components should be considered. 6. Parotid saliva samples are likely to be of greatest value. PMID:7356893

  3. Therapeutic drug monitoring of nevirapine in saliva in Uganda using high performance liquid chromatography and a low cost thin-layer chromatography technique.

    Science.gov (United States)

    Lamorde, Mohammed; Fillekes, Quirine; Sigaloff, Kim; Kityo, Cissy; Buzibye, Allan; Kayiwa, Joshua; Merry, Concepta; Nakatudde-Katumba, Lillian; Burger, David; de Wit, Tobias F Rinke

    2014-09-01

    In resource limited settings access to laboratory monitoring of HIV treatment is limited and therapeutic drug monitoring is generally unavailable. This study aimed to evaluate nevirapine concentrations in saliva using low-cost thin-layer chromatography (TLC) and nevirapine concentrations in plasma and saliva using high performance liquid chromatography (HPLC) methods; and to correlate nevirapine plasma concentrations to HIV treatment outcomes in Ugandan patients. Paired plasma and stimulated saliva samples were obtained from Ugandan, HIV-infected adults on nevirapine-based ART. Nevirapine concentrations were measured using a validated HPLC method and a novel TLC method. Plasma nevirapine concentrations HPLC were considered subtherapeutic. Negative/positive predictive values of different thresholds for subtherapeutic nevirapine concentrations in saliva were determined. Virologic testing and, if applicable, HIV drug resistance testing was performed. Median (interquartile range, IQR) age of 297 patients was 39.1 (32.8-45.2) years. Three hundred saliva and 287 plasma samples were available for analysis. Attempts failed to determine nevirapine saliva concentrations by TLC. Using HPLC, median (IQR) nevirapine concentrations in saliva and plasma were 3.40 (2.59-4.47) mg/L and 6.17 (4.79-7.96) mg/L, respectively. The mean (coefficient of variation,%) nevirapine saliva/plasma ratio was 0.58 (62%). A cut-off value of 1.60 mg/L nevirapine in saliva was associated with a negative/positive predictive value of 0.99/0.72 and a sensitivity/specificity of 87%/98% for predicting subtherapeutic nevirapine plasma concentrations, respectively. Only 5% (15/287) of patients had subtherapeutic nevirapine plasma concentrations, of which 3 patients had viral load results > 400 copies/mL. Patients with nevirapine concentrations in plasma 400 copies/mL). The low-cost TLC technique for monitoring nevirapine in saliva was unsuccessful but monitoring nevirapine saliva and plasma

  4. Psychometric properties of the Alcohol Use Disorders Identification Test (AUDIT) and prevalence of alcohol use among Iranian psychiatric outpatients.

    Science.gov (United States)

    Noorbakhsh, Simasadat; Shams, Jamal; Faghihimohamadi, Mohamadmahdi; Zahiroddin, Hanieh; Hallgren, Mats; Kallmen, Hakan

    2018-01-30

    Iran is a developing and Islamic country where the consumption of alcoholic beverages is banned. However, psychiatric disorders and alcohol use disorders are often co-occurring. We used the Alcohol Use Disorders Identification Test (AUDIT) to estimate the prevalence of alcohol use and examined the psychometric properties of the test among psychiatric outpatients in Teheran, Iran. AUDIT was completed by 846 consecutive (sequential) patients. Descriptive statistics, internal consistency (Cronbach alpha), confirmatory and exploratory factor analyses were used to analyze the prevalence of alcohol use, reliability and construct validity. 12% of men and 1% of women were hazardous alcohol consumers. Internal reliability of the Iranian version of AUDIT was excellent. Confirmatory factor analyses showed that the construct validity and the fit of previous factor structures (1, 2 and 3 factors) to data were not good and seemingly contradicted results from the explorative principal axis factoring, which showed that a 1-factor solution explained 77% of the co-variances. We could not reproduce the suggested factor structure of AUDIT, probably due to the skewed distribution of alcohol consumption. Only 19% of men and 3% of women scored above 0 on AUDIT. This could be explained by the fact that alcohol is illegal in Iran. In conclusion the AUDIT exhibited good internal reliability when used as a single scale. The prevalence estimates according to AUDIT were somewhat higher among psychiatric patients compared to what was reported by WHO regarding the general population.

  5. Electromedical devices test laboratories accreditation

    International Nuclear Information System (INIS)

    Murad, C; Rubio, D; Ponce, S; Alvarez Abri, A; Terron, A; Vicencio, D; Fascioli, E

    2007-01-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University

  6. Some Biological Activities of Malaysian Leech Saliva Extract

    Directory of Open Access Journals (Sweden)

    Abdualrahman M. Abdualkader

    2011-12-01

    Full Text Available Normal 0 21 false false false MS X-NONE AR-SA Leeches were fed on the phagostimulatory solution through parafilm membrane. The satiated leeches were forced to regurgitate the solution by soaking them in an ice-container. The anticoagulant activity was ascertained using thrombin time assay (TT. The result revealed that the saliva concentration which increases TT by 100% (IC100 is 43.205µg/ml plasma. The antimicrobial activity of the saliva was tested against several bacterial spp. (E.coli, P.aeruginosa, B.cereus, Sal.typhi and S.aureus  and fungi spp. (C.albicans and C.neoformans. It was found that saliva has an inhibition activity against Sal.typhi (minimal inhibitory concentration MIC 78.253µg/ml, S.aureus (MIC 78.253µg/ml and E.coli (MIC 121.256µg/ml.ABSTRAK: Pacat-pacat diberi makan larutan phagostimulatory menerusi membran parafilem. Pacat-pacat yang kekenyangan itu dipaksa memuntahkan larutan tersebut dengan direndam di dalam bekas berisi ais. Aktiviti antigumpal ditentukan menggunakan cerakin masa trombin (TT. Keputusan menunjukkan kepekatan air liur pacat menyebabkan pertambahan TT sebanyak 100% (IC100 iaitu 43.205µg/ml plasma. Aktiviti antimikrob air liur telah diuji dengan pelbagai jenis bakteria (E.coli, P.aeruginosa, B.cereus, Sal.typhi dan S.aureus dan pelbagai jenis kulat (C.albicans and C.neoformans. Didapati air liur menghasilkan aktiviti perencatan terhadap Sal.typhi (kepekatan perencat minima (Minimal inhibitory concentration - MIC 78.253µg/ml, S.aureus (MIC 78.253µg/ml dan E.coli (MIC 121.256µg/ml.

  7. Comparisons of Korsakoff and Non-Korsakoff Alcoholics on Neuropsychological Tests of Prefrontal Brain Functioning

    Science.gov (United States)

    Oscar-Berman, Marlene; Kirkley, Shalene M.; Gansler, David A.; Couture, Ashley

    2014-01-01

    Background Evidence suggests that alcoholics exhibit particular deficits in brain systems involving the prefrontal cortex, but few studies have directly compared patients with and without Korsakoff’s syndrome on measures of prefrontal integrity. Methods Neuropsychological tasks sensitive to dysfunction of frontal brain systems were administered, along with standard tests of memory, intelligence, and visuospatial abilities, to 50 healthy, abstinent, nonamnesic alcoholics, 6 patients with alcohol-induced persisting amnestic disorder (Korsakoff’s syndrome), 6 brain-damaged controls with right hemisphere lesions, and 82 healthy nonalcoholic controls. Results Korsakoff patients were impaired on tests of memory, fluency, cognitive flexibility, and perseveration. Non-Korsakoff alcoholics showed some frontal system deficits as well, but these were mild. Cognitive deficits in non-Korsakoff alcoholics were related to age, duration of abstinence (less than 5 years), duration of abuse (more than 20 years), and amount of alcohol intake. Conclusions Abnormalities of frontal system functioning are most apparent in alcoholics with Korsakoff’s syndrome. In non-Korsakoff alcoholics, factors contributing to cognitive performance are age, duration of abstinence, duration of alcoholism, and amount of alcohol consumed. PMID:15100620

  8. Usefulness of saliva for measurement of 3,4-methylenedioxymethamphetamine and its metabolites: correlation with plasma drug concentrations and effect of salivary pH.

    Science.gov (United States)

    Navarro, M; Pichini, S; Farré, M; Ortuño, J; Roset, P N; Segura, J; de la Torre, R

    2001-10-01

    Saliva is an alternative biologic matrix for drugs-of-abuse testing that offers the advantages of noninvasive, rapid, and easy sampling. We studied the excretion profile of 3,4-methylenedioxymethamphetamine (MDMA) and its metabolites in both saliva and plasma, as well the effect of the drug on salivary pH. Saliva and plasma samples were obtained from eight healthy MDMA consumers after ingestion of a single 100-mg dose of the drug. Concentrations of MDMA and its main metabolites, 3,4-methylenedioxyamphetamine (MDA) and 4-hydroxy-3-methoxymethamphetamine (HMMA), in saliva and plasma were measured by gas chromatography-mass spectrometry. Apparent pharmacokinetic parameters for MDMA in saliva were estimated, and the saliva-to-plasma ratio at each time interval was calculated and correlated with salivary pH. MDMA, MDA, and HMMA were detected in saliva. Salivary concentrations of MDMA were 1728.9-6510.6 microg/L and peaked at 1.5 h after drug intake. This was followed by a progressive decrease, with a mean concentration of 126.2 microg/L at 24 h. The saliva-to-plasma ratio was 32.3-1.2, with a peak of 18.1 at 1.5 h after drug administration. Salivary pH seemed to be affected by MDMA administration; pH values decreased by 0.6 units (mean pH values of 6.9 and 6.8 at 1.5 and 4 h after drug administration vs predose pH of 7.4). Measurement of MDMA in saliva is a valuable alternative to determination of plasma drug concentrations in both clinical and toxicologic studies. On-site testing is also facilitated by noninvasive and rapid collection of salivary specimens.

  9. Short communication: Ability of dogs to detect cows in estrus from sniffing saliva samples.

    Science.gov (United States)

    Fischer-Tenhagen, C; Tenhagen, B-A; Heuwieser, W

    2013-02-01

    Efficient estrus detection in high-producing dairy cows is a permanent challenge for successful reproductive performance. In former studies, dogs have been trained to identify estrus-specific odor in vaginal fluid, milk, urine, and blood samples under laboratory conditions with an accuracy of more than 80%. For on-farm utilization of estrus-detection dogs it would be beneficial in terms of hygiene and safety if dogs could identify cows from the feed alley. The objective of this proof of concept study was to test if dogs can be trained to detect estrus-specific scent in saliva of cows. Saliva samples were collected from cows in estrus and diestrus. Thirteen dogs of various breeds and both sexes were trained in this study. Five dogs had no experience in scent detection, whereas 8 dogs had been formerly trained for detection of narcotics or cancer. In the training and test situation, dogs had to detect 1 positive out of 4 samples. Dog training was based on positive reinforcement and dogs were rewarded with a clicker and food for indicating saliva samples of cows in estrus. A false indication was ignored and documented in the test situation. Dogs with and without prior training were trained for 1 and 5 d, respectively. For determining the accuracy of detection, the position of the positive sample was unknown to the dog handler, to avoid hidden cues to the dog. The overall percentage of correct positive indications was 57.6% (175/304), with a range from 40 (1 dog) to 75% (3 dogs). To our knowledge, this is the first indication that dogs are able to detect estrus-specific scent in saliva of cows. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. Characteristic changes of saliva and taste in burning mouth syndrome patients.

    Science.gov (United States)

    Imura, Hiroko; Shimada, Masahiko; Yamazaki, Yoko; Sugimoto, Kumiko

    2016-03-01

    Burning mouth syndrome (BMS) is characterized by chronic pain with a burning sensation of the tongue and oral mucosa and reported to be often accompanied by subjective xerostomia and dysgeusia. Since the etiology of BMS has not been elucidated, to understand the characteristics of BMS, we measured some components of saliva and taste sensitivity and compared the measured values between BMS and healthy subjects. Unstimulated saliva was collected from 15 female BMS patients and 30 healthy women. The flow rate, viscosity (spinnability) and concentration of secretory IgA (SIgA) of saliva and serum antioxidant capacity were measured. The recognition thresholds for sweet, salty, sour, bitter, and umami tastes were measured by whole-mouth method. The statistical analyses were performed using Student's t-test, and P < 0.05 was considered to be significant. In BMS group, the flow rate of saliva was significantly lower and the spinnability was significantly higher compared with healthy group. The secreted amount of SIgA per min and serum antioxidant capacity was significantly lower in the patients. The threshold for sourness in patients was significantly higher, while those for other tastes did not differ from healthy group. BMS patients showed lower salivary flow and higher salivary spinnability. These results together with decreased SIgA amount, suggest that BMS may be relevant to the deterioration of salivary condition, which could in turn affect taste function. Furthermore, the lower antioxidant capacity in patient's serum suggests that it can serve as a diagnostic tool for BMS. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Protein components in saliva and plaque fluid from irradiated primates

    Energy Technology Data Exchange (ETDEWEB)

    Edgar, W.M.; Bowen, W.H.; Cole, M.F. (Caries Prevention and Research Branch, National Caries Program, NIDR, Bethesda, Maryland, USA)

    1982-01-01

    Irradiation of the major salivary glands of monkeys (Macaca mulatta) fed cariogenic diets leads to caries clinically indistinguishable from radiation caries in man. This study compares the organic compostion of individual samples of plaque fluid and saliva from irradiated and control monkeys receiving the same cariogenic diet. Plaque and saliva were collected from fasting, tranquillised animals. Four irradiated animals were sampled repeatedly as were non-irradiated controls. Total protein, albumin, immunoglobulins A, G, and M, and the third component of complement (C'3) were quantitated in plaque fluid and whole saliva. Salivary amylase and peroxidase activities were also determined. Plaque fluid and saliva samples were also subjected to polyacrylamide gel electrophoresis. The total viable anaerobic count and numbers of Streptococcus mutans were determined in samples of plaque. The results suggest that the major effect of irradiation leading to increased numbers of S. mutans and caries susceptibility is in the amount, and not the composition, of the saliva produced by the residual gland tissue. The scanty flow of saliva may reduce the effectiveness of cleansing, buffering and lubrication mechanisms as well as resulting in a marked reduction in the total amount of specific and non-specific immune factors entering the mouth.

  12. Protein components in saliva and plaque fluid from irradiated primates

    International Nuclear Information System (INIS)

    Edgar, W.M.; Bowen, W.H.; Cole, M.F.

    1982-01-01

    Irradiation of the major salivary glands of monkeys (Macaca mulatta) fed cariogenic diets leads to caries clinically indistinguishable from radiation caries in man. This study compares the organic compostion of individual samples of plaque fluid and saliva from irradiated and control monkeys receiving the same cariogenic diet. Plaque and saliva were collected from fasting, tranquillised animals. Four irradiated animals were sampled repeatedly as were non-irradiated controls. Total protein, albumin, immunoglobulins A, G, and M, and the third component of complement (C'3) were quantitated in plaque fluid and whole saliva. Salivary amylase and peroxidase activities were also determined. Plaque fluid and saliva samples were also subjected to polyacrylamide gel electrophoresis. The total viable anaerobic count and numbers of Streptococcus mutans were determined in samples of plaque. The results suggest that the major effect of irradiation leading to increased numbers of S. mutans and caries susceptibility is in the amount, and not the composition, of the saliva produced by the residual gland tissue. The scanty flow of saliva may reduce the effectiveness of cleansing, buffering and lubrication mechanisms as well as resulting in a marked reduction in the total amount of specific and non-specific immune factors entering the mouth. (author)

  13. Protein components in saliva and plaque fluid from irradiated primates

    Energy Technology Data Exchange (ETDEWEB)

    Edgar, W M; Bowen, W H; Cole, M F [Caries Prevention and Research Branch, National Caries Program, NIDR, Bethesda, Maryland, USA

    1982-01-01

    Irradiation of the major salivary glands of monkeys (Macaca mulatta) fed cariogenic diets leads to caries clinically indistinguishable from radiation caries in man. This study compares the organic compostion of individual samples of plaque fluid and saliva from irradiated and control monkeys receiving the same cariogenic diet. Plaque and saliva were collected from fasting, tranquillised animals. Four irradiated animals were sampled repeatedly as were non-irradiated controls. Total protein, albumin, immunoglobulins A, G, and M, and the third component of complement (C'3) were quantitated in plaque fluid and whole saliva. Salivary amylase and peroxidase activities were also determined. Plaque fluid and saliva samples were also subjected to polyacrylamide gel electrophoresis. The total viable anaerobic count and numbers of Streptococcus mutans were determined in samples of plaque. The results suggest that the major effect of irradiation leading to increased numbers of S. mutans and caries susceptibility is in the amount, and not the composition, of the saliva produced by the residual gland tissue. The scanty flow of saliva may reduce the effectiveness of cleansing, buffering and lubrication mechanisms as well as resulting in a marked reduction in the total amount of specific and non-specific immune factors entering the mouth.

  14. Comparison between three different saliva substitutes in patients with hyposalivation.

    Science.gov (United States)

    Skrinjar, Ivana; Vucicevic Boras, Vanja; Bakale, Iva; Andabak Rogulj, Ana; Brailo, Vlaho; Vidovic Juras, Danica; Alajbeg, Ivan; Vrdoljak, Danko Velimir

    2015-04-01

    The aim of the present study was to compare the efficiency of oral spray based on thermal spring water (Buccotherm®) versus commercial saliva substitute (Xeros®) and marshmallow root on the quality of life in patients with hyposalivation. A total of 60 patients with unstimulated salivary flow rate marshmallow root. Therapy lasted for 2 weeks; everyday, patients used one of the products four times a day. Quality of life was measured by the Croatian version of Oral Health Impact Profile 14 questionnaire, and visual analog scale was used to determine the intensity of dry mouth before and after therapy. Statistical analysis was performed by Wilcoxon signed-rank test and Kruskal-Wallis test. Standardized effect size was calculated for OHIP following treatment. Buccotherm® has shown the biggest effect on quality of life in patients with hyposalivation. Intensity of dry mouth was lower after the applied therapy whatever substitute patients used. We recommend the use of all three saliva substitutes for decreasing the intensity of dry mouth symptoms as well as improvement in the quality of life. Although all tested agents showed beneficial effect in alleviating hyposalivation symptoms, it seems that Buccotherm® was superior to Xeros® and marshmallow root.

  15. Point-of-care diagnosis of periodontitis using saliva: technically feasible but still a challenge

    Directory of Open Access Journals (Sweden)

    Suk eJi

    2015-09-01

    Full Text Available Periodontitis is a chronic inflammation of the periodontium caused by persistent bacterial infection that leads to the breakdown of connective tissue and bone. Because the ability to reconstruct the periodontium is limited after alveolar bone loss, early diagnosis and intervention should be the primary goals of periodontal treatment. However, periodontitis often progresses without noticeable symptoms, and many patients do not seek professional dental care until the periodontal destruction progresses to the point of no return. Furthermore, the current diagnosis of periodontitis depends on time-consuming clinical measurements. Therefore, there is an unmet need for near-patient testing to diagnose periodontitis. Saliva is an optimal biological fluid to serve as a near-patient diagnostic tool for periodontitis. Recent developments in point-of-care (POC testing indicate that a diagnostic test for periodontitis using saliva is now technically feasible. A number of promising salivary biomarkers associated with periodontitis have been reported. A panel of optimal biomarkers must be carefully selected based on the pathogenesis of periodontitis. The biggest hurdle for the POC diagnosis of periodontitis using saliva may be the process of validation in a large, diverse patient population. Therefore, we propose the organization of an International Consortium for Biomarkers of Periodontitis, which will gather efforts to identify, select, and validate salivary biomarkers for the diagnosis of periodontitis.

  16. Microbial Community Profiling of Human Saliva Using Shotgun Metagenomic Sequencing

    OpenAIRE

    Hasan, Nur A.; Young, Brian A.; Minard-Smith, Angela T.; Saeed, Kelly; Li, Huai; Heizer, Esley M.; McMillan, Nancy J.; Isom, Richard; Abdullah, Abdul Shakur; Bornman, Daniel M.; Faith, Seth A.; Choi, Seon Young; Dickens, Michael L.; Cebula, Thomas A.; Colwell, Rita R.

    2014-01-01

    Human saliva is clinically informative of both oral and general health. Since next generation shotgun sequencing (NGS) is now widely used to identify and quantify bacteria, we investigated the bacterial flora of saliva microbiomes of two healthy volunteers and five datasets from the Human Microbiome Project, along with a control dataset containing short NGS reads from bacterial species representative of the bacterial flora of human saliva. GENIUS, a system designed to identify and quantify ba...

  17. Factors determining the passage of drugs from blood into saliva.

    OpenAIRE

    Stephen, K W; McCrossan, J; Mackenzie, D; Macfarlane, C B; Speirs, C F

    1980-01-01

    1. Following single oral dosing of ampicillin, cephalexin, tetracycline, erythromycin estolate, clindamycin and rifampicin to six normal volunteers, antibacterial activity was measured at 1, 3 and 6 h in serum, gingival fluid and minor gland saliva from all subjects and in parotid and submandiabular saliva from three. 2. pH values of all gingival fluid and saliva specimens were noted. 3. Partition coefficients between n-octanol and water were measured for erythromycin, clindamycin and rifampi...

  18. Cell phone use is associated with an inflammatory cytokine profile of parotid gland saliva.

    Science.gov (United States)

    Siqueira, Elisa Carvalho; de Souza, Fabrício Tinôco Alvim; Ferreira, Efigênia; Souza, Renan Pedra; Macedo, Samuel Costa; Friedman, Eitan; Gomez, Marcus Vinícius; Gomes, Carolina Cavaliéri; Gomez, Ricardo Santiago

    2016-10-01

    There is controversy on the effects of the non-ionizing radiation emitted by cell phones on cellular processes and the impact of such radiation exposure on health. The purpose of this study was to investigate whether cell phone use alters cytokine expression in the saliva produced by the parotid glands. Cytokine expression profile was determined by enzyme linked immuno sorbent assay (ELISA) in the saliva produced by the parotid glands in healthy volunteers, and correlated with self-reported cell phone use and laterality. The following parameters were determined, in 83 Brazilian individuals in saliva produced by the parotid glands comparing the saliva from the gland exposed to cell phone radiation (ipsilateral) to that from the contralateral parotid: salivary flow, total protein concentration, interleukin 1 β (IL-1 β), interleukin 6 (IL-6), interleukin 10 (IL-10), interferon γ (IFN-γ), and tumor necrosis factor α (TNF-α) salivary levels by ELISA. After multiple testing correction, decreased IL-10 and increased IL-1β salivary levels in the ipsilateral side compared with the contralateral side (P cell phones for more than 10 years presented higher differences between IL-10 levels in ipsilateral versus contralateral parotids (P = 0.0012). No difference was observed in any of the tested parameters in correlation with cell phone monthly usage in minutes. The exposure of parotid glands to cell phones can alter salivary IL-10 and IL-1β levels, consistent with a pro-inflammatory microenvironment that may be related to heat production. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Drug and Alcohol Testing Results 2008 Annual Report

    Science.gov (United States)

    2010-09-01

    This is the 14th annual report of the results of the Federal Transit Administration's (FTA) Drug and Alcohol Testing : Program. This report summarizes the reporting requirements for calendar year 2008, the requirements of the overall : drug and alcoh...

  20. Saliva of obese patients – is it different?

    Directory of Open Access Journals (Sweden)

    Katarzyna Choromańska

    2015-01-01

    Full Text Available Obesity is a major public health concern that increases the risk of cardiovascular disease, type 2 diabetes and cancer. The incidence of obesity has increased significantly in recent years, not only in adults, but also in adolescents and children. This is evidenced by rapidly developing bariatric surgery, the most effective method of treating morbid obesity. Obesity is a multifactorial disease, and its pathogenesis is not completely understood. Numerous studies have been performed to clarify pathogenetic mechanisms, based mostly on blood and sometimes urine samples. Saliva is easily accessible and can be obtained non-invasively. Our aim was to review studies performed on saliva obtained from obese subjects in order to answer the title question.Obese people have different composition of salivary bacteria. Changes in the concentration of sialic acid, phosphorus and peroxidase activity as well as a lower flow rate of stimulated whole saliva promote dental caries and periodontal disease. Concentrations of salivary uric acid, endocannabinoids and CRP are increased in obesity and may provide a useful index of cardiometabolic risk. Assessment of fasting salivary ghrelin might facilitate choosing the best type of bariatric surgery for a specific patient. A significant decrease in salivary cortisol in women with morbid obesity also seems interesting.There is sufficient evidence to state that the saliva of obese and lean subjects is different. Saliva as an easily accessible research material seems promising, as shown by the few studies performed so far.

  1. Effect of pH and fluoride on behavior of dental ZrO2 ceramics in artificial saliva

    International Nuclear Information System (INIS)

    Mukaeda, L.E.; Robin, A.; Santos, C.; Taguchi, S.P.; Borges Junior, L.A.

    2009-01-01

    A considerable increase in the ceramic products demand occurred due to the evolution of dental restoration techniques and these materials must resist to the complex mouth environment. The pH of saliva can decrease significantly due to the ingestion of acidic foods and beverages and mainly due to reactions occurring during bacteria metabolism that lead to the formation of organic acids. Fluorides are also present in the mouth since fluorides are usually added in drinking water, mouth washes, tooth pastes and gels for the prevention of plaque and caries formation. The combination of low pH and presence of fluorides can lead to the formation of HF and HF 2 - which are detrimental to metallic and probably to ceramic devices. In this work, commercial blocks of ZrO 2 ceramics (ProtMat Materiais Avancados® and Ivoclar®) were immersed in Fusayama artificial saliva of different pHs and fluoride concentrations. The properties of the as-produced ceramics (crystalline phases (XRD), microstructure (SEM), roughness (3D surface topography AFM) and mechanical resistance - Vickers hardness (Hv) and fracture toughness (KIC) were evaluated. Some of these properties were also determined after the immersion tests as well as the mass variation of the samples in order to evaluate the resistance of these ZrO 2 ceramics to degradation under these conditions. (author)

  2. Enamel softening with Coca-Cola and rehardening with milk or saliva.

    Science.gov (United States)

    Gedalia, I; Dakuar, A; Shapira, L; Lewinstein, I; Goultschin, J; Rahamim, E

    1991-06-01

    Rehardening effects by cow's milk and by secreted saliva were investigated, in situ, following softening of human enamel with an acidic beverage (Coca-Cola). Volunteers wearing orthodontic removable appliances participated in the study. The intra-oral test was chosen for measuring microhardness of enamel slabs inserted into the dental appliance. The softening and the rehardening degrees were defined as the alterations between initial- and experimental-microhardness value at the enamel surface. In addition, SEM photos were prepared from the initial and experimental stages. Exposure of enamel slabs to the acidic beverage during 1 hour had a softening effect as expressed by the hardness decrease and visualized by the SEM photo. Rehardening effects following milk or saliva exposures respectively were evident, presumably due to deposited organic and mineral material on the enamel surface.

  3. Rapid antemortem detection of CWD prions in deer saliva.

    Directory of Open Access Journals (Sweden)

    Davin M Henderson

    Full Text Available Chronic wasting disease (CWD is an efficiently transmitted prion disease of cervids, now identified in 22 United States, 2 Canadian provinces and Korea. One hallmark of CWD is the shedding of infectious prions in saliva, as demonstrated by bioassay in deer. It is also clear that the concentration of prions in saliva, blood, urine and feces is much lower than in the nervous system or lymphoid tissues. Rapid in vitro detection of CWD (and other prions in body fluids and excreta has been problematic due to the sensitivity limits of direct assays (western blotting, ELISA and the presence of inhibitors in these complex biological materials that hamper detection. Here we use real-time quaking induced conversion (RT-QuIC to demonstrate CWD prions in both diluted and prion-enriched saliva samples from asymptomatic and symptomatic white-tailed deer. CWD prions were detected in 14 of 24 (58.3% diluted saliva samples from CWD-exposed white-tailed deer, including 9 of 14 asymptomatic animals (64.2%. In addition, a phosphotungstic acid enrichment enhanced the RT-QuIC assay sensitivity, enabling detection in 19 of 24 (79.1% of the above saliva samples. Bioassay in Tg[CerPrP] mice confirmed the presence of infectious prions in 2 of 2 RT-QuIC-positive saliva samples so examined. The modified RT-QuIC analysis described represents a non-invasive, rapid ante-mortem detection of prions in complex biologic fluids, excreta, or environmental samples as well as a tool for exploring prion trafficking, peripheralization, and dissemination.

  4. The association between saliva control, silent saliva penetration, aspiration, and videofluoroscopic findings in Parkinson′s disease patients

    Directory of Open Access Journals (Sweden)

    Ali Rajaei

    2015-01-01

    Full Text Available Background: Dysphagia is a common disorder among patients with Parkinson′s disease (PD. It occurs in up to 80% of all (PD patients during the early stages of the disease and up to 95% in the advanced stages; but professionals may not hear from the patients about dysphagia symptoms until these symptoms reach an advanced stage and lead to medical complications. Materials and Methods: Thirty-three PD patients (mean age 66.09 ± 9.4 years; 24 men, nine women participated in this study at our Neurology Institute, between April 20, 2013, and October 26, 2013. They were asked two questions; one about saliva control and the other about silent saliva penetration and aspiration. Next, they underwent the videofluoroscopic swallowing study (VFSS. Results: The Pearson Correlation coefficient between the Penetration-Aspiration Scale (PAS scores and question 1 scores was 0.48 (P < 0.05, =0.25, and there was a significant correlation between the PAS scores and question 2 scores, and also question 1 scores + question 2 scores (r = 0.589, P < 0.05, =0 and r = 0589, P < 0.05, =0. Conclusions: This study showed a significant correlation between the questions about saliva control, silent saliva penetration, and aspiration, and laryngeal penetration and aspiration during VFSS. Therefore, by using these two questions, the potential silent laryngeal penetration and aspiration during meals could be detected before it led to aspiration pneumonia. Taking the benefit of these questions, as a part of the swallowing assessment of PD patients, is recommended.

  5. Effects of Lactobacillus rhamnosus GG on saliva-derived microcosms

    NARCIS (Netherlands)

    Pham, L.C.; Hoogenkamp, M.A.; Exterkate, R.A.M.; Terefework, Z.; de Soet, J.J.; ten Cate, J.M.; Crielaard, W.; Zaura, E.

    2011-01-01

    Objective The probiotic strain Lactobacillus rhamnosus GG (LGG) is shown to hamper the presence of mutans streptococci in saliva and may have positive effects on oral health. We investigated the effects of LGG on the cariogenic potential and microbial composition of saliva-derived microcosms. Design

  6. The role of electrostatics in saliva-induced emulsion flocculation

    NARCIS (Netherlands)

    Silletti, Erika; Vingerhoeds, Monique H.; Norde, Willem; Van Aken, George A.

    Upon consumption food emulsions undergo different processes, including mixing with saliva. It has been shown that whole saliva induces emulsion flocculation [van Aken, G. A., Vingerhoeds, M. H., & de Hoog, E. H. A. (2005). Colloidal behaviour of food emulsions under oral conditions. In E. Dickinson

  7. 10 CFR 26.67 - Random drug and alcohol testing of individuals who have applied for authorization.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Random drug and alcohol testing of individuals who have... PROGRAMS Granting and Maintaining Authorization § 26.67 Random drug and alcohol testing of individuals who... other entity relies on drug and alcohol tests that were conducted before the individual applied for...

  8. The Alcohol Use Disorders Identification Test and carbohydrate-deficient transferrin in alcohol-related sickness absence.

    Science.gov (United States)

    Hermansson, Ulric; Helander, Anders; Brandt, Lena; Huss, Anders; Rönnberg, Sten

    2002-01-01

    Previous studies have shown that elevated, risky levels of alcohol consumption may lead to higher rates of sickness absence. However, no studies have examined the Alcohol Use Disorders Identification Test (AUDIT) or serum carbohydrate-deficient transferrin (CDT) in relation to sickness absence in the workplace. The purpose of this study was to examine the relationship between sick-days, 12 months before screening, and the AUDIT and CDT (CDTect kit). Serum gamma-glutamyltransferase also was used for comparison. The study was carried out over 36 months in a large workplace and formed part of an ongoing controlled study. In conjunction with a routine health examination, employees were offered the opportunity to undergo an alcohol screening. Absence data were obtained from the company payroll system, and sickness absence was analyzed by using a three-ordinal level cumulative logistic model on the number of sick-days. Odds ratios (OR) and 95% confidence intervals (CI) are reported. Of the 989 subjects who participated in the study, 193 (19.5%) screened positive in relation to either the AUDIT (>or=8 points) or CDT (women), or both. Employees who screened positive with the AUDIT had a significantly higher proportion of sick-days (p = 0.047) compared with those who screened negative (OR = 1.4, CI 1.0-1.9). Neither long, continuous periods of sickness absence nor absence on Mondays or Fridays gave a clear indication of individuals who screened positive on the AUDIT or CDT test. Our data indicate that individuals with moderately elevated or risky levels of alcohol consumption show an increase in sick-days. Accordingly, workplaces have a good reason for using a more systematic approach to alcohol screening in routine workplace health examinations.

  9. Test device for measuring permeability of a barrier material

    Science.gov (United States)

    Reese, Matthew; Dameron, Arrelaine; Kempe, Michael

    2014-03-04

    A test device for measuring permeability of a barrier material. An exemplary device comprises a test card having a thin-film conductor-pattern formed thereon and an edge seal which seals the test card to the barrier material. Another exemplary embodiment is an electrical calcium test device comprising: a test card an impermeable spacer, an edge seal which seals the test card to the spacer and an edge seal which seals the spacer to the barrier material.

  10. Leak test method and test device for iodine filter

    International Nuclear Information System (INIS)

    Fukasawa, Tetsuo; Funabashi, Kiyomi; Miura, Noboru; Miura, Eiichi.

    1995-01-01

    An air introduction device which can change a humidity is disposed upstream of an iodine filter to be tested, and a humidity measuring device is disposed downstream of the iodine filter respectively. At first, dried air reduced with humidity is flown from the air introduction device to the iodine filter, to remove moisture content from an iodine adsorber in the iodine filter. Next, air at an increased humidity is supplied to the iodine filter. The difference between the time starting the supply of the highly humid air and the time detecting the high humidity at the humidity measuring device is measured. When the time difference is smaller than the time difference measured previously in a normal iodine filter, it shows the presence of leak in the iodine filter to be tested. With such procedures, leakage in the iodine filter which removes radioactive iodine from off-gases discharged from the radioactive material handling facilities can be detected easily by using water (steams), namely, a naturally present material. (I.N.)

  11. The Effect of Canal Contamination with Saliva on Apical Sealing

    Directory of Open Access Journals (Sweden)

    S Sabaghi

    2014-08-01

    Methods: In this laboratory study, 58 human uni-root teeth were cleaned and shaped for obturation with gutta percha and sealer AH26. In the case group, specimens were contaminated with human saliva immediately before obturation, whereas the teeth in the control group were kept dry. All canals were filled by lateral condensation technique. Moreover, the teeth were placed in methylene blue dye for 3 days. Dye penetration was measured using a stereomicrosope. As a matter of fact, the study data were analyzed via utilizing t-test. Results: A significant difference was found between the two groups in regard with the apical leakage(P<0.001. The microleakage mean of dye in the dry group was 3/48mm, whereas it was 6/36mm in the saliva contaminated group. Conclusion: The study findings revealed that complete drying of canal can improve apical sealing.

  12. Cultural, behavioral, social, and psychological perceptions of saliva: relevance to clinical diagnostics.

    Science.gov (United States)

    Nguyen, Sean; Wong, David T

    2006-04-01

    The search for a resource that can be used to detect a broad range of diseases easily and reliably is akin to a search for the diagnostic Holy Grail. Yet, each of us may have inside our mouths, a key to the pathological and disease biomarker library hidden inside our bodies. Saliva--the source of all this information--is the secretory product of glands located in or around the oral cavity. If one could read the stories of diagnostic information present within saliva, then the abundance of information waiting to be found could be comparable to a vast vault of information, such as the Internet. Upon dissection of this data, it would be seen that the source of this information is from saliva's origin as a filtrate of blood, and that the validity of both mediums should be equal. Although one day this may be the view, most people's hold of saliva, current and past cultures, have fared much more diverse meanings to the secretion. Ivan Pavlov's experiments has shown how closely tied salivation is with the thought of food, one of life's primary indulgences. The relationship between salivation and behaviors within our daily lives is undeniable. Yet most people never appreciate the uniqueness of saliva. Throughout the world, saliva carries definite positive and negative connotations, based upon its social, psychological, behavioral, and cultural settings. The thought of saliva may be viewed as grotesque in one population, yet may be the vehicle of blessing in other cultures. Saliva's double nature brings up some interesting cultural, social, behavioral, and psychological points about how saliva is perceived in the world, some of which are subsequently stated in order to present saliva as the spirited fluid it is.

  13. Dot-ELISA-IgM in saliva for the diagnosis of human leptospirosis using polyester fabric-resin as support (Preliminary Report Dot-ELISA-IgM em saliva para diagnóstico da leptospirose humana, empregando como suporte tecido de poliéster-resina (Nota Prévia

    Directory of Open Access Journals (Sweden)

    Marcos Vinicius da Silva

    1994-10-01

    Full Text Available In order to improve the diagnosis of human leptospirosis, we standardized the dot-ELISA for the search of specific IgM antibodies in saliva. Saliva and serum samples were collected simultaneously from 20 patients with the icterohemorrhagic form of the disease, from 10 patients with other pathologies and from 5 negative controls. Leptospires of serovars icterohaemorrhagiae, canicola, hebdomadis, brasiliensis and cynopteri grown in EMJH medium and mixed together in equal volumes, were used as antigen at individual protein concentration of 0.2 µg/µl. In the solid phase of the test we used polyester fabric impregnated with N-methylolacrylamide resin. The antigen volume for each test was 1µl, the saliva volume was 8 µl, and the volume of peroxidase-labelled anti-human IgM conjugate was 30 µl. A visual reading was taken after development in freshly prepared chromogen solution. In contrast to the classic nitrocellulose membrane support, the fabric support is easy to obtain and to handle. Saliva can be collected directly onto the support, a fact that facilitates the method and reduces the expenses and risks related to blood processing.Com a finalidade de melhorar o diagnóstico da leptospirose humana, padronizou-se o teste dot-ELISA para a pesquisa de anticorpos específicos da classe IgM na saliva. Empregaram-se amostras de saliva e soro coletadas simultaneamente de 20 pacientes com a forma ictero-hemorrágica da doença, de 10 pacientes com outras patologias e 5 controles negativos. Culturas de Leptos-pira em meio EMJH, dos sorovares: icterohaemorrhagiae, canicola, hebdomadis, brasiliensis e cynopteri, foram utilizadas como antígeno, na concentração proteica individual de 0,2 µg/µl, misturadas em volumes iguais. Na fase sólida do teste empregou-se tecido de po-liéster impregnado com resina de N-metilol-acrilamida. O volume do antígeno para cada teste foi de 1µl, o de saliva 8µl, o de conjugado anti-IgM humana marcada com peroxidase, de

  14. 75 FR 26183 - Procedures for Transportation Workplace Drug and Alcohol Testing Programs

    Science.gov (United States)

    2010-05-11

    ... 2105-AE01 Procedures for Transportation Workplace Drug and Alcohol Testing Programs AGENCY: Office of...: For program issues, Bohdan Baczara, Office of Drug and Alcohol Policy and Compliance, 1200 New Jersey... of Federal Regulations, as follows: [[Page 26184

  15. Oesophageal fistula/tritium-labelled water technique for determining dry matter intake and saliva secretion rates of grazing herbivores

    International Nuclear Information System (INIS)

    Luick, J.R.

    1982-01-01

    Seven assumptions on which the use of tritium-labelled water and oesophageal fistula depend, for determining the dry matter intake and saliva secretion rates of grazing herbivores, were tested experimentally. It is concluded that many of the possible sources of error can be ignored, but that a correction is necessary for the saliva dry matter content when calculating the dry matter of ingested food from fistula samples. (author)

  16. Effects of isoflurane anesthesia and pilocarpine on rat parotid saliva flow

    DEFF Research Database (Denmark)

    Knudsen, Jacob Dronninglund; Nauntofte, Birgitte; Josipovic, M

    2011-01-01

    The purpose of this study was to investigate the effects of isoflurane on unstimulated and pilocarpine-stimulated parotid saliva secretion. Ten male Sprague-Dawley rats weighing 350-400 g were randomized into two groups, and the saliva flow rate and lag phase were measured at two doses of isoflur......The purpose of this study was to investigate the effects of isoflurane on unstimulated and pilocarpine-stimulated parotid saliva secretion. Ten male Sprague-Dawley rats weighing 350-400 g were randomized into two groups, and the saliva flow rate and lag phase were measured at two doses...... of isoflurane in a crossover study design. Increasing the isoflurane concentration from 1% to 2% was associated with a 19% decrease in saliva secretion rate, and the lag to saliva secretion was increased by 155%. To clarify whether the effect of isoflurane (1.5%) on the parotid flow varied with stimulus...... intensity, we measured the parotid flow induced by seven different doses of pilocarpine on sham-irradiated rats and rats irradiated with single doses of 15 Gy. A maximal pilocarpine response was obtained with 1.5 mg/kg in both irradiated and sham-irradiated rats; however, the parotid flow of the irradiated...

  17. Radioimmunological determination of chloramphenicol in the saliva of lactating cows

    International Nuclear Information System (INIS)

    Dotter, A.; Kroker, R.; Arnold, D.; Somogyi, A.

    1987-01-01

    In an effort to search for noninvasive methods suitable to monitor compliance with the ban of chloramphenicol (CAP) in milkproducing animals, the pharmacokinetic behavior of this drug in bovine saliva was investigated. As revealed by studies using a radioimmunological assay, CAP appears following its intracisternal (i.c.) or subcutaneous (s.c.) administration in the saliva of lactating cows. The level of sensitivity of the method (1.5 ng CAP per g saliva) was reached 14 and 18 days after i.c. and s.c. administration, respectively. At present, the question must remain open as to whether the concentration of CAP in the saliva can serve as a reliable indicator for the enforcement of the highest permissible level set at 1 ng CAP per g of milk by German regulations. (orig.) [de

  18. Radioimmunological determination of chloramphenicol in the saliva of lactating cows

    Energy Technology Data Exchange (ETDEWEB)

    Dotter, A.; Kroker, R.; Arnold, D.; Somogyi, A.

    1987-02-01

    In an effort to search for noninvasive methods suitable to monitor compliance with the ban of chloramphenicol (CAP) in milk-producing animals, the pharmacokinetic behavior of this drug in bovine saliva was investigated. As revealed by studies using a radioimmunological assay, CAP appears following its intracisternal (i.c.) or subcutaneous (s.c.) administration in the saliva of lactating cows. The level of sensitivity of the method (1.5 ng CAP per g saliva) was reached 14 and 18 days after i.c. and s.c. administration, respectively. At present, the question must remain open as to whether the concentration of CAP in the saliva can serve as a reliable indicator for the enforcement of the highest permissible level set at 1 ng CAP per g of milk by German regulations.

  19. Flow injection on-line dilution for zinc determination in human saliva with electrothermal atomic absorption spectrometry detection

    Energy Technology Data Exchange (ETDEWEB)

    Burguera-Pascu, Margarita [Department of Oral Medicine, School of Dentistry, University of Granada, Granada (Spain)], E-mail: margaburpas@hotmail.com; Rodriguez-Archilla, Alberto [Department of Oral Medicine, School of Dentistry, University of Granada, Granada (Spain); Burguera, Jose Luis; Burguera, Marcela; Rondon, Carlos; Carrero, Pablo [Department of Chemistry, Faculty of Sciences, University of Los Andes, Merida (Venezuela)

    2007-09-26

    An automated method is described for the determination of zinc in human saliva by electrothermal atomic absorption spectrometry (ET AAS) after on-line dilution of samples with a significant reduction of sample consumption per analysis (<0.4 mL including the dead volume of the system). In order to fulfill this aim without changing the sample transport conduits during the experiments, a flow injection (FI) dilution system was constructed. Its principal parts are: one propulsion device (peristaltic pump, PP) for either samples, standards or washing solution all located in an autosampler tray and for the surfactant solution (Triton X-100) used as diluent, and a two-position time based solenoid injector (TBSI{sub 1}) which allowed the introduction of 10 {mu}L of either solution in the diluent stream. To avoid unnecessary waste of samples, the TBSI{sub 1} also permitted the recirculation of the solutions to their respective autosampler cups. The downstream diluted solution fills a home made sampling arm assembly. The sequential deposition of 20 {mu}L aliquots of samples or standards on the graphite tube platform was carried out by air displacement with a similar time based solenoid injector (TBSI{sub 2}). The dilution procedure and the injection of solutions into the atomizer are computer controlled and synchronized with the operation of the temperature program. Samples or standards solutions were submitted to two drying steps (at 90 and 130 deg. C), followed by pyrolysis and atomization at 700 and 1700 deg. C, respectively. The aqueous calibration was linear up to 120.0 {mu}g L{sup -1} for diluted standard solutions/samples and its slope was similar (p > 0.05) to the standard addition curve, indicating lack of matrix effect. The precision tested by repeated analysis of real saliva samples was less than 3% and the detection limit (3{sigma}) was of 0.35 {mu}g L{sup -1}. To test the accuracy of the proposed procedure, recovery tests were performed, obtaining mean recovery

  20. Computational strategy for quantifying human pesticide exposure based upon a saliva measurement

    Energy Technology Data Exchange (ETDEWEB)

    Timchalk, Charles; Weber, Thomas J.; Smith, Jordan N.

    2015-05-27

    The National Research Council of the National Academies report, Toxicity Testing in the 21st Century: A Vision and Strategy, highlighted the importance of quantitative exposure data for evaluating human toxicity risk and noted that biomonitoring is a critical tool for quantitatively evaluating exposure from both environmental and occupational settings. Direct measurement of chemical exposures using personal monitoring provides the most accurate estimation of a subject’s true exposure, and non-invasive methods have also been advocated for quantifying the pharmacokinetics and bioavailability of drugs and xenobiotics. In this regard, there is a need to identify chemicals that are readily cleared in saliva at concentrations that can be quantified to support the implementation of this approach.. The current manuscript describes the use of computational modeling approaches that are closely coupled to in vivo and in vitro experiments to predict salivary uptake and clearance of xenobiotics. The primary mechanism by which xenobiotics leave the blood and enter saliva is thought to involve paracellular transport, passive transcellular diffusion, or trancellular active transport with the majority of drugs and xenobiotics cleared from plasma into saliva by passive diffusion. The transcellular or paracellular diffusion of unbound chemicals in plasma to saliva has been computational modeled using a combination of compartmental and physiologically based approaches. Of key importance for determining the plasma:saliva partitioning was the utilization of a modified Schmitt algorithm that calculates partitioning based upon the tissue composition, pH, chemical pKa and plasma protein-binding. Sensitivity analysis of key model parameters specifically identified that both protein-binding and pKa (for weak acids and bases) had the most significant impact on the determination of partitioning and that there were clear species dependent differences based upon physiological variance between

  1. Autologous saliva transfusion: treatment for HIV?

    Science.gov (United States)

    Arakeri, Gururaj

    2010-05-01

    The HIV-1 pandemic is a complex mix of diverse epidemics within and between countries and regions of the world, and is undoubtedly the defining public-health crisis of our time. Any therapeutic or prophylactic measure which holds promise or provides clues of eliminating or inhibiting the infection is worthy of investigation. As our body's own saliva is suspiciously escaping from the infection and providing clues regarding the resistance/inhibition of HIV; in this paper, a treatment approach is suggested with the rationale of in vitro effective antiviral action of autogenous saliva may also have a better therapeutic potential by its intravenous administration along with dextran.

  2. Can Saliva and Plasma Methadone Concentrations Be Used for Enantioselective Pharmacokinetic and Pharmacodynamic Studies in Patients With Advanced Cancer?

    Science.gov (United States)

    George, Rani; Haywood, Alison; Good, Phillip; Hennig, Stefanie; Khan, Sohil; Norris, Ross; Hardy, Janet

    2017-09-01

    Methadone is a potent analgesic used to treat refractory cancer pain. It is administered as a racemic mixture, with the l-enantiomer being primarily a μ-receptor agonist, whereas the d-enantiomer is an N-methyl-d-aspartate antagonist and inhibits serotonin and norepinephrine reuptake. Dose requirements vary greatly among patients to achieve optimal pain control and to avoid the risk of adverse effects. The relationship between plasma and saliva methadone enantiomer concentrations was investigated to determine if saliva could be a substitute for plasma in pharmacodynamic and pharmacokinetic studies for clinical monitoring and dose optimization of methadone in patients with advanced cancer. Patients with advanced cancer who were prescribed varying doses of oral methadone for pain management were recruited to obtain paired plasma and saliva samples. Pain scores were recorded at the time of sampling. The total and unbound plasma and saliva concentrations of the l- and d-enantiomers of methadone were quantified by using an HPLC-MS/MS method. The relationship between plasma (total and unbound) and saliva concentrations were compared. The saliva-to-plasma concentration ratio was compared versus the dose administered and the time after dosing for both enantiomers. The association of methadone concentrations with reported pain scores was compared by using a Mann-Whitney U test for significance. Fifty patients receiving a mean dose of 11mg/d of methadone provided 151 paired plasma and saliva samples. The median age of the population was 61 years with an interquartile range of 53-71 years with total body weight ranging from 59-88 kg. Median (interquartile) total plasma concentrations for l- and d-methadone were 50.78 ng/mL (30.6-113.0 ng/mL) and 62.0 ng/mL (28.7-116.0 ng/mL), respectively. Median (interquartile range) saliva concentrations for l- and d-methadone were 81.5 ng/mL (28.0-203.2 ng/mL) and 44.2 (16.2-149.7 ng/mL). No relationship could be established between

  3. Unstimulated salivary flow rate, pH and buffer capacity of saliva in healthy volunteers.

    Science.gov (United States)

    Fenoll-Palomares, C; Muñoz Montagud, J V; Sanchiz, V; Herreros, B; Hernández, V; Mínguez, M; Benages, A

    2004-11-01

    To assess the salivary flow rate, pH, and buffer capacity of healthy volunteers, and their relationships with age, gender, obesity, smoking, and alcohol consumption, and to establish the lower-end value of normal salivary flow (oligosialia). A prospective study was conducted in 159 healthy volunteers (age > 18 years, absence of medical conditions that could decrease salivary flow). Unstimulated whole saliva was collected during ten minutes, and salivary flow rate (ml/min), pH, and bicarbonate concentration (mmol/l) were measured using a Radiometer ABL 520. The 5 percentile of salivary flow rate and bicarbonate concentration was considered the lower limit of normality. Median salivary flow rate was 0.48 ml/min (range: 0.1-2 ml/min). Age younger than 44 years was associated with higher flow rates (OR 2.10). Compared with women, men presented a higher flow rate (OR 3.19) and buffer capacity (OR 2.81). Bicarbonate concentration correlated with salivary flow rate. The lower-end values of normal flow rate and bicarbonate concentration were 0.15 ml/min and 1.800 mmol/l, respectively. The presence of obesity, smoking, and alcohol consumption did not influence salivary parameters. In healthy volunteers, salivary flow rate depends on age and gender, and correlates with buffer capacity. Obesity, smoking, and alcohol use do not influence salivary secretion.

  4. Diametral tensile strength of two dental composites when immersed in ethanol, distilled water and artificial saliva.

    Science.gov (United States)

    Rehman, Abdur; Amin, Faiza; Abbas, Muhammad

    2014-11-01

    To examine the effect of distilled water, artificial saliva and ethanol on the tensile strength of direct tooth-coloured restorative material. The study was conducted at Dr. Ishrat ul Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences (DUHS), Karachi, from April 2011 to September 2012. The testing was performed at the Pakistan Council of Scientific and Industrial Research (PCSIR) laboratories. Two composite resins Filtek Z250 and Spectrum TPH were tested. Specimens (13 mm x 3 mm x 2 mm) of each material were prepared in the stainless steel mould according to the manufacturers' instructions and distributed into 3 equal groups: one immersed in distilled water, the other in artificial saliva, and the last one in ethanol for 24 hours. Tensile strength was determined after 24 hours in universal Instron Testing Machine. There were 72 specimens in all; 36 (50%) each for Filtek Z250 and Spectrum TPH. The three sub-groups in each case had 12 (33.3%) specimens. For the Filtek Z250, there was no statistically significant difference between immersion in distilled water and artificial saliva, but the ethanol group presented lower tensile strength (ptensile strength compared to distilled water (ptested composite resins were affected by the immersion media and adversely affected the mechanical properties of composite resins.

  5. Effect of pH and fluoride on behavior of dental ZrO{sub 2} ceramics in artificial saliva

    Energy Technology Data Exchange (ETDEWEB)

    Mukaeda, L.E.; Robin, A.; Santos, C.; Taguchi, S.P.; Borges Junior, L.A., E-mail: luizamukaeda@gmail.com, E-mail: alain@demar.eel.usp.br, E-mail: claudinei@demar.eel.usp.br, E-mail: simone@demar.eel.usp.br, E-mail: borges.jr@itelefonica.com.br [Universidade de Sao Paulo (EEL/DEMAR/USP), Lorena, SP (Brazil). Escola de Engenharia; Machado, J.P.B., E-mail: joaopaulo@las.inpe.br [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil)

    2009-07-01

    A considerable increase in the ceramic products demand occurred due to the evolution of dental restoration techniques and these materials must resist to the complex mouth environment. The pH of saliva can decrease significantly due to the ingestion of acidic foods and beverages and mainly due to reactions occurring during bacteria metabolism that lead to the formation of organic acids. Fluorides are also present in the mouth since fluorides are usually added in drinking water, mouth washes, tooth pastes and gels for the prevention of plaque and caries formation. The combination of low pH and presence of fluorides can lead to the formation of HF and HF{sub 2}{sup -} which are detrimental to metallic and probably to ceramic devices. In this work, commercial blocks of ZrO{sub 2} ceramics (ProtMat Materiais Avancados® and Ivoclar®) were immersed in Fusayama artificial saliva of different pHs and fluoride concentrations. The properties of the as-produced ceramics (crystalline phases (XRD), microstructure (SEM), roughness (3D surface topography AFM) and mechanical resistance - Vickers hardness (Hv) and fracture toughness (KIC) were evaluated. Some of these properties were also determined after the immersion tests as well as the mass variation of the samples in order to evaluate the resistance of these ZrO{sub 2} ceramics to degradation under these conditions. (author)

  6. Saliva from nymph and adult females of Haemaphysalis longicornis: a proteomic study.

    Science.gov (United States)

    Tirloni, Lucas; Islam, Mohammad Saiful; Kim, Tae Kwon; Diedrich, Jolene K; Yates, John R; Pinto, Antônio F M; Mulenga, Albert; You, Myung-Jo; Da Silva Vaz, Itabajara

    2015-06-24

    Haemaphysalis longicornis is a major vector of Theileria spp., Anaplasma phagocytophilum, Babesia spp. and Coxiella burnetti in East Asian countries. All life stages of ixodid ticks have a destructive pool-feeding style in which they create a pool-feeding site by lacerating host tissue and secreting a variety of biologically active compounds that allows the tick to evade host responses, enabling the uptake of a blood meal. The identification and functional characterization of tick saliva proteins can be useful to elucidate the molecular mechanisms involved in tick development and to conceive new anti-tick control methods. H. longicornis tick saliva was collected from fully engorged nymphs and fully engorged adults induced by dopamine or pilocarpine, respectively. Saliva was digested with trypsin for LC-MS/MS sequencing and peptides were searched against tick and rabbit sequences. A total of 275 proteins were identified, of which 135 were tick and 100 were rabbit proteins. Of the tick proteins, 30 proteins were identified exclusively in fully engorged nymph saliva, 74 in fully engorged adult females, and 31 were detected in both stages. The identified tick proteins include heme/iron metabolism-related proteins, oxidation/detoxification proteins, enzymes, proteinase inhibitors, tick-specific protein families, and cytoskeletal proteins. Proteins involved in signal transduction, transport and metabolism of carbohydrate, energy, nucleotide, amino acids and lipids were also detected. Of the rabbit proteins, 13 were present in nymph saliva, 48 in adult saliva, and 30 were present in both. The host proteins include immunoglobulins, complement system proteins, antimicrobial proteins, serum albumin, peroxiredoxin, serotransferrin, apolipoprotein, hemopexin, proteinase inhibitors, and hemoglobin/red blood cells-related products. This study allows the identification of H. longicornis saliva proteins. In spontaneously detached tick saliva various proteins were identified

  7. Fluoride kinetics in saliva after the use of a fluoride-containing chewing gum Cinética de flúor na saliva após o uso de uma goma de mascar fluoretada

    Directory of Open Access Journals (Sweden)

    Maria Francisca Thereza Borro Bijella

    2005-12-01

    Full Text Available There is a relationship between the use of fluoride, the reduction of dental caries and the increase of dental fluorosis. The purpose of this study was to analyze the fluoride kinetics in saliva after using the HappydentTM chewing gum, which contains 3.38 mg of fluoride as monofluorophosphate. Fifteen 7-9-year-old volunteers were instructed to chew the gum TridentTM (control and HappydentTM on different days. Total saliva was collected for 3 minutes, at 0, 3, 6, 9, 15, 30 and 45 minutes after starting chewing. Salivary fluoride was analyzed with a fluoride-specific electrode (Orion 96-09 after acid hydrolysis. The data were analyzed by two-way analysis of variance and by Tukey’s post hoc test (p Há uma relação entre o uso de fluoretos, a redução na cárie e o aumento da fluorose dentária. O objetivo deste estudo foi analisar a cinética do flúor na saliva após o uso da goma de mascar Happydent®, que contém 3,38 mg de flúor como monofluorfosfato. A saliva foi coletada de 15 voluntários entre 7 e 9 anos de idade, durante 3 minutos nos intervalos de 0, 3, 6, 9, 15, 30 e 45 minutos. Inicialmente, a coleta foi realizada com o Trident® (controle e, após 24 h, a coleta foi repetida com a goma de mascar Happydent®. O flúor foi analisado com um eletrodo íon-específico (Orion 96-09 após a realização da hidrólise ácida. Os dados foram analisados através da análise de variância a dois critérios e pelo teste de Tukey (p < 0,05. A quantidade média ± dp (mg de flúor liberado na saliva foi 0,276 ± 0,126 e 0,024 ± 0,014 para o Happydent® e o Trident®, respectivamente. A quantidade de flúor nas amostras de saliva após o uso do Happydent® foi significativamente maior do que após o uso do Trident® em todos os tempos experimentais, com exceção dos períodos de 30 e 45 minutos. A alta quantidade de flúor na saliva após o uso do Happydent® poderia ser eficiente na prevenção da cárie dentária, o que deveria ser avaliado

  8. Saliva in relation to dental erosion before and after radiotherapy

    DEFF Research Database (Denmark)

    Jensdottir, Thorbjorg; von Buchwald, Christian; Nauntofte, Birgitte

    2013-01-01

    Abstract Objective. Low saliva flow and abnormal saliva composition are common conditions after radiotherapy for oral cavity and pharyngeal cancer. Both conditions increase the susceptibility to dental caries and erosion, which may be further accelerated by changes in food preferences. The aim...... of this study was to determine changes in saliva flow and susceptibility to erosive challenges in pharyngeal cancer patients before and after radiotherapy to the head and neck. Materials and methods: The erosive potential of sucking acidic candies with and without calcium was determined in nine patients (50...

  9. APR1400 Fluidic Device Sensitivity Test

    International Nuclear Information System (INIS)

    Choi, Nam Hyun; Chu, In Cheol; Min, Kyong Ho; Song, Chul Hwa

    2005-12-01

    In the safety injection tank at the emergency core cooling system of APR1400, a new safety design feature, passive fluidic device is equipped which includes no active driving system. It is essential to evaluate the new design feature with various experiments. For this reason, three categories of sensitivity tests have been performed in the present study. As the first sensitivity experiment, the effect of the height of the stand pipe was investigated. The second sensitivity test was conducted with removing the insert plate gasket to examine its effect. The effect of the expansion of the control nozzle width was ascertained from the third sensitivity test. The results of each test showed that the passive fluidic device which will be equipped in the SIT tank of APR1400 has great integrity and repeatability

  10. Work Stress and Alcohol Use: Developing and Testing a Biphasic Self-Medication Model

    OpenAIRE

    Frone, Michael R.

    2016-01-01

    This study developed and tested a moderated-mediation model of work stress and alcohol use, based on the biphasic (stimulant and sedative) effects of alcohol and the self-medication and stress-vulnerability models of alcohol use. The model proposes that exposure to work stressors can increase both negative affect and work fatigue, and that these two sources of strain can subsequently motivate the use of alcohol. However, the relations of negative affect and work fatigue to a...

  11. Isolation and Analytical Characterization of Local Malaysian Leech Saliva

    Directory of Open Access Journals (Sweden)

    Mohamed Alaama

    2011-12-01

    Full Text Available Leech saliva contains biologically active compounds that are mainly proteins and peptides. In this study a modified and smooth extraction method of saliva was used without leeches' scarification. UV and Bradford Assay protein methods showed that the saliva extract contains high concentrations of proteins. RP-HPLC chromatogram revealed that more than 30 different peaks were observed in leech saliva extract. Gel electrophoresis revealed the existence of proteins and peptides with different molecular weights. The gel showed up to 25 different bands. Comparison of gel electrophoresis data with protein database revealed the closeness of four molecular weights to known proteins from Hirudinaria leech family. Other proteins detected by gel electrophoresis may be related to completely new biologically active proteins and peptides in the saliva extract or to a modification (isoforms of the existing ones or finally to a mixture of both.ABSTRAK: Air liur pacat secara biologinya mengandungi sebahagian besar campuran aktif protein dan peptida. Dalam kajian ini, kaedah pengestrakan air liur pacat yang telah diubah suai digunakan tanpa perlu membunuh pacat. Kaedah protein Cerakin UV dan Bradford menunjukkan air liur pacat yang diekstrak mengandungi konsentrasi protein yang tinggi. Kromatogram RP-HPLC memperlihatkan lebih daripada 30 puncak berbeza diperolehi semasa air liur pacat diekstrak. Gel elektroforesis memperlihatkan kewujudan protein dan peptida dengan berat molekul yang berbeza. Gel menunjukkan hingga 25 jalur yang berbeza. Perbandingan data menggunakan gel elektroforesis seiring dengan pangkalan data protein memperlihatkan persamaan empat berat molekul, dengan protein yang yang dikenali daripada keluarga pacat Hirudinaria. Jenis protein lain yang dikesan dengan menggunakan gel elektrofosis mungkin juga berkait secara biologinya dengan protein dan peptida aktif yang baru, dalam ekstrak air liur atau pengubahsuaian (beberapa jenis yang berbeza daripada

  12. 78 FR 77196 - Random Drug and Alcohol Testing Percentage Rates of Covered Aviation Employees for the Period of...

    Science.gov (United States)

    2013-12-20

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... the minimum random drug and alcohol testing percentage rates for the period January 1, 2014, through... Federal Regulations Title 14, section 120.109(b) (for drug testing), and 120.217(c) (for alcohol testing...

  13. Development and testing of the Youth Alcohol Norms Survey (YANS) instrument to measure youth alcohol norms and psychosocial influences.

    Science.gov (United States)

    Burns, Sharyn K; Maycock, Bruce; Hildebrand, Janina; Zhao, Yun; Allsop, Steve; Lobo, Roanna; Howat, Peter

    2018-05-14

    This study aimed to develop and validate an online instrument to: (1) identify common alcohol-related social influences, norms and beliefs among adolescents; (2) clarify the process and pathways through which proalcohol norms are transmitted to adolescents; (3) describe the characteristics of social connections that contribute to the transmission of alcohol norms; and (4) identify the influence of alcohol marketing on adolescent norm development. The online Youth Alcohol Norms Survey (YANS) was administered in secondary schools in Western Australia PARTICIPANTS: Using a 2-week test-retest format, the YANS was administered to secondary school students (n=481, age=13-17 years, female 309, 64.2%). The development of the YANS was guided by social cognitive theory and comprised a systematic multistage process including evaluation of content and face validity. A 2-week test-retest format was employed. Exploratory factor analysis was conducted to determine the underlying factor structure of the instrument. Test-retest reliability was examined using intraclass correlation coefficient (ICC) and Cohen's kappa. A five-factor structure with meaningful components and robust factorial loads was identified, and the five factors were labelled as 'individual attitudes and beliefs', 'peer and community identity', 'sibling influences', 'school and community connectedness' and 'injunctive norms', respectively. The instrument demonstrated stability across the test-retest procedure (ICC=0.68-0.88, Cohen's kappa coefficient=0.69) for most variables. The results support the reliability and factorial validity of this instrument. The YANS presents a promising tool, which enables comprehensive assessment of reciprocal individual, behavioural and environmental factors that influence alcohol-related norms among adolescents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise

  14. The Alcohol Use Disorders Identification Test-Consumption (AUDIT-C) in the assessment of alcohol use disorders among acute injury patients.

    Science.gov (United States)

    Wade, Darryl; Varker, Tracey; Forbes, David; O'Donnell, Meaghan

    2014-01-01

    The Alcohol Use Disorders Identification Test-Consumption (AUDIT-C) is a brief alcohol screening test and a candidate for inclusion in recommended screening and brief intervention protocols for acute injury patients. The objective of the current study was to examine the performance of the AUDIT-C to risk stratify injury patients with regard to their probability of having an alcohol use disorder. Participants (n = 1,004) were from a multisite Australian acute injury study. Stratum-specific likelihood ratio (SSLR) analysis was used to examine the performance of previously recommended AUDIT-C risk zones based on a dichotomous cut-point (0 to 3, 4 to 12) and risk zones derived from SSLR analysis to estimate the probability of a current alcohol use disorder. Almost a quarter (23%) of patients met criteria for a current alcohol use disorder. SSLR analysis identified multiple AUDIT-C risk zones (0 to 3, 4 to 5, 6, 7 to 8, 9 to 12) with a wide range of posttest probabilities of alcohol use disorder, from 5 to 68%. The area under receiver operating characteristic curve (AUROC) score was 0.82 for the derived AUDIT-C zones and 0.70 for the recommended AUDIT-C zones. A comparison between AUROCs revealed that overall the derived zones performed significantly better than the recommended zones in being able to discriminate between patients with and without alcohol use disorder. The findings of SSLR analysis can be used to improve estimates of the probability of alcohol use disorder in acute injury patients based on AUDIT-C scores. In turn, this information can inform clinical interventions and the development of screening and intervention protocols in a range of settings. Copyright © 2013 by the Research Society on Alcoholism.

  15. A population-based study of how children are exposed to saliva in KwaZulu-Natal Province, South Africa: implications for the spread of saliva-borne pathogens to children

    Science.gov (United States)

    Butler, L. M.; Neilands, T. B.; Mosam, A.; Mzolo, S.; Martin, J. N.

    2014-01-01

    Summary Objectives In sub-Saharan Africa, many viral infections, including Epstein–Barr virus, cytomegalovirus, Kaposi’s sarcoma-associated herpesvirus and hepatitis B are acquired in childhood. While saliva is an important transmission conduit for these viruses, little is known about how saliva is passed to African children. We endeavoured to identify the range and determinants of acts by which African children are exposed to saliva. Methods To identify the range of acts by which African children are exposed to saliva, we conducted focus groups, semi-structured interviews and participant observations in an urban and a rural community in South Africa. To measure the prevalence and determinants of the identified acts, we administered a questionnaire to a population-based sample of caregivers. Results We identified 12 caregiving practices that expose a child’s oral–respiratory mucosa, cutaneous surfaces or anal–rectal mucosa to saliva. Several acts were heretofore not described in the contemporary literature (e.g., caregiver inserting finger lubricated with saliva into child’s rectum to relieve constipation). Among 896 participants in the population-based survey, many of the acts were commonly practised by all respondent types (mothers, fathers, grandmothers and siblings). The most common were premastication of food, sharing sweets and premastication of medicinal plants that are spit onto a child’s body. Conclusions African children are exposed to saliva through a variety of acts, practised by a variety of caregivers, with no single predominant practice. This diversity poses challenges for epidemiologic work seeking to identify specific saliva-passing practices that transmit viruses. Most acts could be replaced by other actions and are theoretically preventable. PMID:20149165

  16. 75 FR 76069 - Random Drug and Alcohol Testing Percentage Rates of Covered Aviation Employees for the Period of...

    Science.gov (United States)

    2010-12-07

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... minimum random drug and alcohol testing percentage rates for the period January 1, 2011, through December... Regulations Title 14, section 120.109(b) (for drug testing), and 120.217(c) (for alcohol testing). Issued in...

  17. 77 FR 71669 - Random Drug and Alcohol Testing Percentage Rates of Covered Aviation Employees for the Period of...

    Science.gov (United States)

    2012-12-03

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... the minimum random drug and alcohol testing percentage rates for the period January 1, 2013, through... Regulations Title 14, Sec. Sec. 120.109(b) (for drug testing), and 120.217(c) (for alcohol testing). Issued in...

  18. 76 FR 74843 - Random Drug and Alcohol Testing Percentage Rates of Covered Aviation Employees for the Period of...

    Science.gov (United States)

    2011-12-01

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration Random Drug and Alcohol Testing... the minimum random drug and alcohol testing percentage rates for the period January 1, 2012, through... Regulations Title 14, Sec. 120.109(b) (for drug testing), and 120.217(c) (for alcohol testing). Issued in...

  19. Validación de la versión española del Test Stroop de Alcohol

    Directory of Open Access Journals (Sweden)

    Alvaro Sánchez-López

    2015-05-01

    Full Text Available El sesgo atencional para el alcohol se ha mostrado útil para identificar a personas con consumo patológico así como a personas dependientes con altas probabilidades de recaída. El objetivo de este trabajo fue validar la versión española del Test Stroop de Alcohol diseñado para evaluar el sesgo atencional en pacientes dependientes del alcohol. La muestra estuvo compuesta por 173 participantes divididos en dos grupos: Un grupo de pacientes (n = 88 cumpliendo criterios de dependencia alcohólica y un grupo control (n = 85 con riesgo bajo de consumo de alcohol, que realizaron el Test de palabras y colores de Stroop (Stroop clásico, el Test de Stroop neutro y el Test de Stroop de Alcohol. Se observaron diferencias estadísticamente significativas en las interferencias para el Stroop Clásico y el Stroop de Alcohol. Los pacientes con dependencia, en comparación a los participantes control, mostraron mayores interferencias para estímulos de contenido alcohólico que para estímulos de contenido neutro. Este efecto fue explicado por un sesgo atencional para información relacionada con el alcohol en pacientes con dependencia. Se calcularon curvas COR, observándose áreas bajo la curva estadísticamente significativas para las interferencias del Stroop clásico y del Stroop de alcohol. Este trabajo sirvió para validar la versión española del Test Stroop de Alcohol para evaluar sesgos atencionales hacia el alcohol en personas con problemas de consumo y dependencia alcohólica.

  20. Relationship of serum and saliva calcium, phosphorus and alkaline phosphatase with dry mouth feeling in menopause.

    Science.gov (United States)

    Agha-Hosseini, Farzaneh; Mirzaii-Dizgah, Iraj; Moosavi, Mahdieh-Sadat

    2012-06-01

    The aim of this study was to compare serum and saliva calcium, phosphorus and alkaline phosphatase of menopausal women with/without dry mouth (DM) feeling. The composition of saliva in menopause women with/without DM feeling is different. Some of these differences are in hormones that are related to bone turnover. A case-control study was carried out on 60 selected menopausal women aged 45-79 years with or without DM feeling (30 as case, 30 as control), conducted at the Clinic of Oral Medicine, Tehran University of Medical Sciences. The phosphorus concentration was measured by photometrical measurement of the blue colour formed after the addition of ammonium molybdate and stannous chloride; calcium was measured by Arsenazo reaction; and alkaline phosphatase by the pNPP-AMP method. Statistical analysis of Student's t-test was used. The mean serum phosphorus and alkaline phosphatase, stimulated and unstimulated saliva calcium and alkaline phosphatase levels were significantly higher in the menopausal women suffering from DM. There were no significant differences between groups regarding saliva phosphorus and serum calcium concentration. Calcium, phosphorus and alkaline phosphatase appear associated with DM feeling in menopause. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  1. 75 FR 59105 - Procedures for Transportation Workplace Drug and Alcohol Testing Programs: Federal Drug Testing...

    Science.gov (United States)

    2010-09-27

    ... 2105-AE03 Procedures for Transportation Workplace Drug and Alcohol Testing Programs: Federal Drug... the Federal workplace drug testing program but also pointed out that ``* * * the Department of.... Executive Order 12866 and Regulatory Flexibility Act This Interim Final Rule is not significant for purposes...

  2. AC-conductance and capacitance measurements for ethanol vapor detection using carbon nanotube-polyvinyl alcohol composite based devices.

    Science.gov (United States)

    Greenshields, Márcia W C C; Meruvia, Michelle S; Hümmelgen, Ivo A; Coville, Neil J; Mhlanga, Sabelo D; Ceragioli, Helder J; Quispe, Jose C Rojas; Baranauskas, Vitor

    2011-03-01

    We report the preparation of inexpensive ethanol sensor devices using multiwalled carbon nanotube-polyvinyl alcohol composite films deposited onto interdigitated electrodes patterned on phenolite substrates. We investigate the frequency dependent response of the device conductance and capacitance showing that higher sensitivity is obtained at higher frequency if the conductance is used as sensing parameter. In the case of capacitance measurements, higher sensitivity is obtained at low frequency. Ethanol detection at a concentration of 300 ppm in air is demonstrated. More than 80% of the sensor conductance and capacitance variation response occurs in less than 20 s.

  3. Corrosion Performance of Fe-Cr-Ni Alloys in Artificial Saliva and Mouthwash Solution

    Science.gov (United States)

    Porcayo-Calderon, J.; Casales-Diaz, M.; Salinas-Bravo, V. M.; Martinez-Gomez, L.

    2015-01-01

    Several austenitic stainless steels suitable for high temperature applications because of their high corrosion resistance and excellent mechanical properties were investigated as biomaterials for dental use. The steels were evaluated by electrochemical techniques such as potentiodynamic polarization curves, cyclic polarization curves, measurements of open circuit potential, and linear polarization resistance. The performance of steels was evaluated in two types of environments: artificial saliva and mouthwash solution at 37°C for 48 hours. In order to compare the behavior of steels, titanium a material commonly used in dental applications was also tested in the same conditions. Results show that tested steels have characteristics that may make them attractive as biomaterials for dental applications. Contents of Cr, Ni, and other minor alloying elements (Mo, Ti, and Nb) determine the performance of stainless steels. In artificial saliva steels show a corrosion rate of the same order of magnitude as titanium and in mouthwash have greater corrosion resistance than titanium. PMID:26064083

  4. Effect of saliva contamination on cementation of orthodontic brackets using different adhesive systems.

    Science.gov (United States)

    Robaski, Aliden-Willian; Pamato, Saulo; Tomás-de Oliveira, Marcelo; Pereira, Jefferson-Ricardo

    2017-07-01

    The enamel condition and the quality of surface are points that need to be considered for achieving optimal efficiency in the treatment with orthodontic brackets. The aim of this study was to assess the immediate bond strength of metallic brackets cemented to dental. Forty human premolars were double-sectioned, placed in PVC matrices and randomly divided into 10 groups (n=8). They received artificial saliva contamination before or after the application of adhesive systems, except for the control groups. The metallic brackets were cemented using two orthodontic cements (Transbond™ Plus Color Change, 3M Unitek e Transbond™ XT Light, 3M Unitek). The specimens were subjected to mechanical shear bond strength testing and classified according to the fracture pattern. The results were analyzed using a two-way ANOVA and Tukey's test for multiple comparisons ( p brackets cemented on the dental enamel. Key words: Bonding, orthodontic brackets, shear bond strength, saliva, adhesive systems.

  5. Composition of betel specific chemicals in saliva during betel chewing for the identification of biomarkers

    Science.gov (United States)

    Franke, Adrian A.; Mendez, Ana Joy; Lai, Jennifer F.; Arat-Cabading, Celine; Li, Xingnan; Custer, Laurie J.

    2015-01-01

    Betel nut chewing causes cancer in humans including strong associations with head and neck cancer in Guam. In the search for biomarkers of betel chewing we sought to identify chemicals specific for the 3 most commonly consumed betel preparations in Guam: nut (‘BN’), nut + Piper betle leaf (‘BL’), and betel quid (‘BQ’) consisting of nut+lime+tobacco+Piper betle leaf. Chemicals were extracted from the chewing material and saliva of subjects chewing these betel preparations. Saliva analysis involved protein precipitation with acetonitrile, dilution with formic acid followed by LCMS analysis. Baseline and chewing saliva levels were compared using t-tests and differences between groups were compared by ANOVA; p<0.05 indicated significance. Predominant compounds in chewing material were guvacine, arecoline, guvacoline, arecaidine, chavibetol, and nicotine. In chewing saliva we found significant increases from baseline for guvacine (BN, BQ), arecoline (all groups), guvacoline (BN), arecaidine (all groups), nicotine (BQ), and chavibetol (BL, BQ) and significant differences between all groups for total areca- specific alkaloids, total tobacco-specific alkaloids and chavibetol. From this pilot study, we propose the following chemical patterns as biomarkers: areca alkaloids for BN use, areca alkaloids and chavibetol for BL use, and areca alkaloids plus chavibetol and tobacco-specific alkaloids for BQ use. PMID:25797484

  6. Effect of dental restorative materials on total antioxidant capacity and calcium concentration of unstimulated saliva.

    Science.gov (United States)

    Ramezani, Gholam H; Moghadam, Mona-Momeni; Saghiri, Mohammad-Ali; Garcia-Godoy, Franklin; Asatourian, Armen; Aminsobhani, Mohsen; Scarbecz, Mark; Sheibani, Nader

    2017-01-01

    To evaluate the effect of dental amalgam and composite restorations on total antioxidant capacity (TAC) and calcium (Ca) ion concentration of unstimulated saliva. Forty-eight children aged 6-10 years selected and divided into three groups of sixteen (8 males, 8 females). In group A and B, samples consisted of two class II dental composite or amalgam restorations, while in group C samples were caries-free (control group). Unstimulated saliva from all samples was collected and TAC was measured by spectrophotometry using an adaptation of 2, 2'-azino-di-(3-ethylbenzthiazoline-6-sulphonate) (ABTS) assay. The Ca ion level was estimated by an auto- analyzer. Data were analyzed with one- and two-way ANOVA test, at a p difference between groups ( p differences within and between groups ( p Gender is an effective factor in changes induced in oral cavity as females showed more emphatic reaction to dental filling materials than males. Patients who have dental restorations, especially dental composites, should pay more attention to their dental hygiene, because dental restorations can increase oxidative stress and decrease Ca ion level in saliva, which might jeopardize remineralization process of tooth structures after demineralization. Key words: Amalgam, caries, composite, saliva, total antioxidant capacity.

  7. Evaluation of Rapid Stain IDentification (RSID™ Reader System for Analysis and Documentation of RSID™ Tests

    Directory of Open Access Journals (Sweden)

    Pravatchai W. Boonlayangoor

    2013-08-01

    Full Text Available The ability to detect the presence of body fluids is a crucial first step in documenting and processing forensic evidence. The Rapid Stain IDentification (RSID™ tests for blood, saliva, semen and urine are lateral flow immunochromatographic strip tests specifically designed for forensic use. Like most lateral flow strips, the membrane components of the test are enclosed in a molded plastic cassette with a sample well and an observation window. No specialized equipment is required to use these tests or to score the results seen in the observation window; however, the utility of these tests can be enhanced if an electronic record of the test results can be obtained, preferably by a small hand-held device that could be used in the field under low light conditions. Such a device should also be able to “read” the lateral flow strips and accurately record the results of the test as either positive, i.e., the body fluid was detected, or negative, i.e., the body fluid was not detected. Here we describe the RSID™ Reader System—a ruggedized strip test reader unit that allows analysis and documentation of RSID™ lateral flow strip tests using pre-configured settings, and show that the RSID™ Reader can accurately and reproducibly report and record correct results from RSID™ blood, saliva, semen, and urine tests.

  8. HPV detection rate in saliva may depend on the immune system efficiency.

    Science.gov (United States)

    Adamopoulou, Maria; Vairaktaris, Eleftherios; Panis, Vassilis; Nkenke, Emeka; Neukam, Friedreich W; Yapijakis, Christos

    2008-01-01

    Human papilloma virus (HPV) has been established as a major etiological factor of anogenital cancer. In addition, HPV has also been implicated in oral carcinogenesis but its detection rates appear to be highly variable, depending on the patient population tested, the molecular methodology used, as well as the type of oral specimen investigated. For example, saliva is an oral fluid that may play a role in HPV transmission, although the detection rates of the virus are lower than tissue. Recent evidence has indicated that HPV-related pathology is increased in the oral cavity of human immunodeficiency virus (HIV)-positive individuals. In order to investigate whether the presence of different HPV types in saliva depends on immune system efficiency, oral fluid samples of patients with oral cancer and without any known immune deficiency were compared with those of HIV-positive individuals. Saliva samples were collected from 68 patients with oral squamous cell carcinoma and 34 HIV seropositive individuals. HPV DNA sequences were detected by L1 concensus polymerase chain reaction (PCR), followed by restriction fragment length polymorphism (RFLP) analysis and DNA sequencing for HPV typing. HPV DNA was detected in 7/68 (10.3%) of the oral cancer patients and in 12/34 (35.3%) of the HIV-positive individuals, a highly significant difference (p = 0.006; odds ratio 4.753; 95% confidence interval 1.698-13.271). Among HPV-positive samples, the prevalence of HPV types associated with high oncogenic risk was similar in oral cancer and HIV-positive cases (71.4% and 66.7%, respectively). In both groups, the most common HPV type was high-risk 16 (50% and 42.8%, respectively). Although a similar pattern of HPV high-risk types was detected in oral cancer and HIV-positive cases, the quantitative detection of HPV in saliva significantly depended on immune system efficiency. Furthermore, the significantly increased detection rates of HPV in saliva of HIV-positive individuals may be

  9. Testing the Efficacy of Alcohol Labels with Standard Drink Information and National Drinking Guidelines on Consumers' Ability to Estimate Alcohol Consumption.

    Science.gov (United States)

    Hobin, Erin; Vallance, Kate; Zuo, Fei; Stockwell, Tim; Rosella, Laura; Simniceanu, Alice; White, Christine; Hammond, David

    2018-01-01

    Despite the introduction of national drinking guidelines in Canada, there is limited public knowledge of them and low understanding of 'standard drinks (SDs)' which limits the likelihood of guidelines affecting drinking behaviour. This study tests the efficacy of alcohol labels with SD information and Canada's Low-Risk Drinking Guidelines (LRDGs) as compared to %ABV labels on consumers' ability to estimate alcohol intake. It also examines the label size and format that best supports adults' ability to make informed drinking choices. This research consisted of a between-groups experiment (n = 2016) in which participants each viewed one of six labels. Using an online survey, participants viewed an alcohol label and were asked to estimate: (a) the amount in a SD; (b) the number of SDs in an alcohol container and (c) the number of SDs to consume to reach the recommended daily limit in Canada's LRDG. Results indicated that labels with SD and LRDG information facilitated more accurate estimates of alcohol consumption and awareness of safer drinking limits across different beverage types (12.6% to 58.9% increase in accuracy), and labels were strongly supported among the majority (66.2%) of participants. Labels with SD and LRDG information constitute a more efficacious means of supporting accurate estimates of alcohol consumption than %ABV labels, and provide evidence to inform potential changes to alcohol labelling regulations. Further research testing labels in real-world settings is needed. Results indicate that the introduction of enhanced alcohol labels combining standard drink information and national drinking guidelines may be an effective way to improve drinkers' ability to accurately assess alcohol consumption and monitor intake relative to guidelines. Overall support for enhanced labels suggests probable acceptability of introduction at a population level. © The Author 2017. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  10. Development and Validation of the Alcohol Identity Implicit Associations Test (AI-IAT)

    Science.gov (United States)

    Gray, Heather M.; LaPlante, Debi A.; Bannon, Brittany L.; Ambady, Nalini; Shaffer, Howard J.

    2011-01-01

    Alcohol identity is the extent to which an individual perceives drinking alcohol to be a defining characteristic of his or her self-identity. Although alcohol identity might play an important role in risky college drinking practices, there is currently no easily administered, implicit measure of this concept. Therefore we developed a computerized implicit measure of alcohol identity (the Alcohol Identity Implicit Associations Test; AI-IAT) and assessed its reliability and predictive validity in relation to risky college drinking practices. One hundred forty-one college students completed the AI-IAT. Again 3- and 6-months later, we administered the AI-IAT and indices of engagement in risky college drinking practices. A subset of participants also completed the previously-validated implicit measure of alcohol identity. Scores on the AI-IAT were stable over time, internally consistent, and positively correlated with the previously-validated measure of alcohol identity. Baseline AI-IAT scores predicted future engagement in risky college drinking practices, even after controlling for standard alcohol consumption measures. We conclude that the AI-IAT reliably measures alcohol identity, a concept that appears to play an important role in risky college drinking practices. PMID:21621924

  11. Effect of Saliva Contamination on Microleakage Beneath Bonded Brackets: A Comparison between Two Moisture-Tolerant Bonding Systems

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Toodehzaeim

    2016-03-01

    Full Text Available Objectives: This study aimed to evaluate the effects of saliva contamination on the metallic bracket microleakage bonded with two moisture-tolerant bonding systems.Materials and Methods:  Ninety freshly extracted premolar teeth were randomly divided into six groups of 15 with the following treatments: G1 (control: After acid etching, Assure primer and Assure adhesive were applied to non-contaminated enamel surfaces. G2 (contaminated after etching: The etched enamel surface was exposed to saliva, then Assure primer and Assure adhesive were applied. G3 (contaminated after priming: Saliva contamination was done after application of Assure primer. The exact same procedures were applied to groups G4 to G6 except that TIMP primer and Transbond Plus adhesive system were used.  To measure the microleakage score, the teeth were stained with 2% methylene blue for 24 hours, sectioned and examined under a stereomicroscope at ×16 magnification. Data analysis was performed using Fisher’s exact test.Results: In dry conditions, Assure and TMIP were not significantly different in terms of microleakage scores.  All contaminated groups exhibited higher microleakage score at the enamel/adhesive interface compared to the bracket/adhesive interface (P< 0.01. In wet conditions, Assure groups showed higher microleakage at the enamel-adhesive interface compared to the TMIP groups (P<0.05. At the bracket-adhesive interface, the microleakage scores were not significantly different in saliva contaminated groups compared to the controls. Conclusion: Saliva contamination caused greater microleakage at the enamel-adhesive interface compared to the adhesive-bracket interface.Keywords: Orthodontic Brackets; Adhesives; Saliva

  12. CHROMOGRANIN A DETECTION IN SALIVA OF TYPE 2 DIABETES PATIENTS

    Directory of Open Access Journals (Sweden)

    Martine Soell

    2010-02-01

    Full Text Available Chromogranin A is present in secretion granules of nerve, endocrine and immune cells and is a precursor of several peptides with antibacterial and antifungal properties at micromolar concentrations.Our aim in this prospective, double blind study, was to determine the expression of chromogranin A and its peptides at protein level in saliva of type 2 diabetic patients and thereby to obtain a new non-invasive diagnostic means for the future.Saliva was taken from 30 type 2 diabetic patients and 30 healthy individuals at the same time interval in the morning without any oral stimuli. Circadianic periodics in protein productions have been avoided. The presence of chromogranin A and its derived peptides was determined in whole saliva, after centrifugation at 40C for 12 min at 14 000 rpm, by SDS-PAGE electrophoresis and Immunoblotting (Western Blot. To ensure same protein concentrations Bradford protein quantification assay has been performed before.For the first time, we have determined an overexpression of chromogranin A in saliva of diabetic patients in 100% of the individuals.Chromogranin A, a circulating biomarker for epithelial tumours, is also overexpressed in saliva of type 2 diabetic patients. To confirm our results, more studies with a large amount of patients is necessary.

  13. Chromogranin A Detection in Saliva of Type 2 Diabetes Patients

    Directory of Open Access Journals (Sweden)

    Martine Soell

    2010-02-01

    Full Text Available Chromogranin A is present in secretion granules of nerve, endocrine and immune cells and is a precursor of several peptides with antibacterial and antifungal properties at micromolar concentrations.Our aim in this prospective, double blind study, was to determine the expression of chromogranin A and its peptides at protein level in saliva of type 2 diabetic patients and thereby to obtain a new non-invasive diagnostic means for the future.Saliva was taken from 30 type 2 diabetic patients and 30 healthy individuals at the same time interval in the morning without any oral stimuli. Circadianic periodics in protein productions have been avoided. The presence of chromogranin A and its derived peptides was determined in whole saliva, after centrifugation at 4°C for 12 min at 14 000 rpm, by SDS-PAGE electrophoresis and Immunoblotting (Western Blot. To ensure same protein concentrations Bradford protein quantification assay has been performed before.For the first time, we have determined an overexpression of chromogranin A in saliva of diabetic patients in 100% of the individuals.Chromogranin A, a circulating biomarker for epithelial tumours, is also overexpressed in saliva of type 2 diabetic patients. To confirm our results, more studies with a large amount of patients is necessary.

  14. [Effect of saliva contamination on microleakage around class-5 cavities restored with three different types of adhesive materials].

    Science.gov (United States)

    Iovan, Gianina; Stoleriu, Simona; Andrian, S; Dia, V; Căruntu, Irina Draga

    2004-01-01

    The recent improvement of adhesive materials should decrease the risk related to saliva contamination. The aim of this study was to evaluate the effect of saliva contamination on the microleakage within class V cavities restored with three different types of materials: conventional glass ionomer cement, composite resin and compomer. 30 human extracted teeth were randomly divided in 3 equal groups. In each group, class V cavities were prepared on both facial and lingual surfaces (but joint for glass ionomer cement and bevelled incisal margin for composite resin and compomer). The lingual cavities were contaminated with saliva prior to restoration, while the facial cavities were not contaminated, serving as control. After water storage for 24 hours, teeth were immersed in 1% methylene blue solution for 24 hours. The axial sections were viewed under an optical microscope and the extent of dye penetration along cervical, axial and incisal margins was measured in millimetres. Statistic analysis showed that under salivary contamination, microleakage increased along the cervical margin of restoration for all three tested materials. Saliva contamination resulted in microleakage within the axial wall of the cavity only for the conventional glass ionomer cement. These data indicate that composite resin and compomer used together with new adhesives seem to be less sensitive to saliva contamination compared to conventional materials. However, under saliva contamination, cervical microleakage cannot be completely prevented and proper isolation should still be mandatory.

  15. Control substances and alcohol use and testing

    Energy Technology Data Exchange (ETDEWEB)

    Przybylski, J.L.

    1994-07-01

    The Omnibus Transportation Employee Testing Act was signed into law in October of 1991. The Omnibus Transportation Employee Testing Act of 1991 required the United States Department of Transportation (DOT) to enact regulations requiring the testing of employees that perform ``safety sensitive functions`` for illegal controlled substance use and alcohol misuse. The Transportation Management Division, Office of Environmental Restoration and Waste Management (TMD/EM-261), United States Department of Energy (DOE), Training Program Manager is committed to promoting the availability of the necessary information to those affected members of the Department of Energy (DOE) community in an effort to attain the highest possible level of regulatory compliance and to enhance the safety of each individual in the workplace.

  16. Human papillomavirus 13 in a Mexican Mayan community with multifocal epithelial hyperplasia: could saliva be involved in household transmission?

    Science.gov (United States)

    Lopez-Villanueva, Maria Eugenia; Conde-Ferráez, Laura; Ayora-Talavera, Guadalupe; Cerón-Espinosa, Jose D; González-Losa, Maria del Refugio

    2011-01-01

    Multifocal epithelial hyperplasia (MEH) is a disease of the oral mucosa. Human papillomaviruses 13 and 32 have been detected in these lesions. We describe the epidemiology and clinical characteristics of patients with MEH in a rural community in the Mayan area of Mexico with 53 cases and 54 controls. Clinical and epidemiological data were collected through a direct interview. Oral cell samples were collected with a cytobrush. Subjects collected their own saliva sample in a sterile bottle. All samples were tested for HPV 13 and 32 by polymerase chain reaction using specific primers. Of the 53 patients and 54 healthy subjects, 56% were < 12 years old, 25% were males and 75% females. Evolution of the lesions was between two months and 17 years. The lesions affected lips, jugal mucosa, and tongue, 96% had multiple lesions. From 53 patients, fifty samples of oral cells and 31 samples of saliva were analyzed. HPV 13 was detected in 100% oral cell and 100% saliva samples studied. 16 healthy subjects were HVP 13 positive. A highly significant association of HPV 13 infection and MEH was found, as determined by chi square test (p = 0.00) Household transmission of HPV 13 may happen through saliva and the shared use of contaminated objects.

  17. Pengaruh Berkumur Air Kelapa Muda Terhadap Ph Saliva

    OpenAIRE

    Mokoginta, Zuthra P

    2017-01-01

    PENGARUH BERKUMUR AIR KELAPA MUDA TERHADAP pH SALIVA Zuthra P. Mokoginta1) , Vonny N.S. Wowor1) , Juliatri1) 1)Program Studi Pendidikan Dokter Gigi, Fakultas Kedokteran UNSRAT Manado, 95115 ABSTRACT Saliva is one factor that contributes to the development of caries, particularly in the process of demineralization. The low pH in the oral cavity will facilitate the growth of acidogenic bacteria such as Streptococcus mutans and Lactobacillus which is the main cause microorganisms in th...

  18. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    Directory of Open Access Journals (Sweden)

    Adilson Yoshio Furuse

    2007-12-01

    Full Text Available The purpose of this study was to investigate the effect of different surface treatments on shear bond strength of saliva-contaminated resin-resin interfaces. Flat resin surfaces were fabricated. In the control group, no contamination or surface treatment was performed. The resin surfaces of the experimental groups were contaminated with saliva and air-dried, and then submitted to: (G1 rinsing with water and drying; (G2 application of an adhesive system; (G3 rinsing and drying, abrasion with finishing disks, etching and application of adhesive system; (G4 rinsing and drying, etching, application of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin-resin interfaces with saliva significantly reduced shear strength, especially after prolonged storage (p<0.05. Similar values to the original bond strength were obtained after abrasion and application of adhesive (G3 or etching and application of silane and adhesive (G4. If contamination occurs, a surface treatment is required to guarantee an adequate interaction between the resin increments.

  19. A test device for premixed gas turbine combustion oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Richards, G.A.; Gemmen, R.S.; Yip, M.J.

    1996-03-01

    This report discusses design and operation of a single-nozzle test combustor for studying lean, premixed combustion oscillations from gas turbine fuel nozzles. It was used to study oscillations from a prototype fuel nozzle that produced oscillations during testing in a commercial engine. Similar, but not identical, oscillations were recorded in the test device. Basic requirements of the device design were that the flame geometry be maintained and acoustic losses be minimized; this was achieved by using a Helmholtz resonator as the combustor geometry. Surprisingly, the combustor oscillated strongly at several frequencies, without modification of the resonator. Brief survey of operating conditions suggests that it may be helpful to characterize oscillating behavior in terms of reference velocity and inlet air temperature with the rig backpressure playing a smaller role. The preliminary results do not guarantee that the single-nozzle test device will reproduce arbitrary oscillations that occur on a complete engine test. Nozzle/nozzle interactions may complicate the response, and oscillations controlled by acoustic velocities transverse to the nozzle axis may not be reproduced in a test device that relies on a bulk Helmholtz mode. Nevertheless, some oscillations can be reproduced, and the single-nozzle test device allows both active and passive control strategies to be tested relatively inexpensively.

  20. Devices for fatigue testing of electroplated nickel (MEMS)

    DEFF Research Database (Denmark)

    Larsen, Kristian Pontoppidan; Ravnkilde, J. T.; Ginnerup, Morten

    2002-01-01

    μm and an effective length from 4μm to 27μm. Maximum stresses of the test beam were calculated to be 500MPa to 2100MPa by use of FEM tools. The test results indicate very promising fatigue properties of nano-nickel, as none of the test devices have shown fatigue failure or even initiation of cracks......In-situ fatigue test devices with integrated electrostatic actuator were fabricated in electroplated nanocrystalline nickel (nano-nickel). The devices feature in-plane approximately pure bending with fixed displacement of the test specimen of the dimensions: widths from 2μm to 3.7μm, a height of 7...... after 108 cycles. The combination of high strength and toughness, which is known for nanocrystalline materials, together with very small test specimens and low surface roughness could be the explanation for the good fatigue properties....

  1. The performance of the Alcohol Use Disorder Identification Test (AUDIT) in detecting alcohol abuse and dependence in a population of depressed or anxious persons

    NARCIS (Netherlands)

    Boschloo, Lynn; Vogelzangs, Nicole; Smit, Johannes H.; van den Brink, Wim; Veltman, Dick J.; Beekman, Aartjan T. F.; Penninx, Brenda W. J. H.

    2010-01-01

    BACKGROUND: Alcohol use disorders are highly prevalent but often remain unrecognized among depressed and/or anxious persons. This study examines the performance of the Alcohol Use Disorder Identification Test (AUDIT) in detecting alcohol abuse and dependence in this high-risk group and compares it

  2. Reliability Generalization of the Alcohol Use Disorder Identification Test.

    Science.gov (United States)

    Shields, Alan L.; Caruso, John C.

    2002-01-01

    Evaluated the reliability of scores from the Alcohol Use Disorders Identification Test (AUDIT; J. Sounders and others, 1993) in a reliability generalization study based on 17 empirical journal articles. Results show AUDIT scores to be generally reliable for basic assessment. (SLD)

  3. Results from the 2012 drug and alcohol testing survey : [analysis brief].

    Science.gov (United States)

    2014-12-01

    This report summarizes the results of the 2012 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses (CDLs) who test positive for...

  4. Results from the 2015 Drug and Alcohol Testing Survey : analysis brief.

    Science.gov (United States)

    2017-06-01

    This report summarizes the results of the 2015 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...

  5. Results from the 2014 drug and alcohol testing survey : analysis brief.

    Science.gov (United States)

    2016-10-01

    This report summarizes the results of the 2014 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...

  6. Results from the 2016 Drug and Alcohol Testing Survey : Analysis Brief

    Science.gov (United States)

    2018-01-01

    This report summarizes the results of the 2016 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of commercial drivers license (CDL) drivers who test positive for contro...

  7. Candida in saliva of Brazilian hemophilic patients Candida na saliva de pacientes hemofílicos brasileiros

    Directory of Open Access Journals (Sweden)

    Claudio Maranhão Pereira

    2004-12-01

    Full Text Available Hemophilia is a common hereditary hemorrhagic disorder, however little is known about the oral microflora of hemophilic patients. The aim of this study was to quantify the Candida and identify its species in non-stimulated saliva of hemophilic patients, and consider its relationship with clinical factors influencing Candida carriage. This study comprised evaluation of 86 hemophilic patients of the Hematology Center/UNICAMP and 43 healthy subjects as controls. All patients were submitted to anamnesis, intraoral examination and unstimulated saliva collection. Candida counts and species identification were performed in salivary samples. Candida was present in 64% of the hemophilic patients and in 44% of the healthy controls. C. albicans represented 65% and 68% of the isolated species, in hemophiliacs and control group respectively, and C. tropicalis was the second most common species in both groups. These results indicate that hemophilic patients carry Candida more frequently and in higher counts than healthy controls, independently of oral clinical parameter considered, as viral infections, complete dentures, transfusions of hemoderivatives, and salivary flow.Hemofilia é uma alteração hemorrágica hereditária comum, entretanto pouco se sabe a respeito da microbiota oral destes indivíduos. O objetivo deste estudo foi quantificar a presença de Candida e identificar as suas espécies na saliva de hemofílicos, correlacionando os resultados com fatores clínicos que possam influenciar a presença deste fungo. Foram avaliados 86 hemofílicos do Hemocentro/UNICAMP e 43 indivíduos saudáveis. Todos os pacientes foram submetidos a anamnese, exame clínico intra-oral e coleta de saliva de forma não estimulada. A quantificação e identificação das espécies de Candida foram realizadas nas amostras de saliva. Candida estava presente em 64% dos hemofílicos e em 44% dos indivíduos saudáveis. C. albicans representou 65% e 68% das esp

  8. Performance test of wet type decontamination device

    International Nuclear Information System (INIS)

    Lee, E. P.; Kim, E. G.; Min, D. K.; Jun, Y. B.; Lee, H. K.; Seu, H. S.; Kwon, H. M.; Hong, K.P.

    2003-01-01

    The intervention area located at rear hot cell can be contaminated by hot cell maintenance work. For effective decontamination of the intervention floor a wet type decontamination device was developed. The device was assembled with a brush rotating part, a washing liquid supplying part, an intake part for recovering contaminated liquid and a device moving cart part. The device was made of stainless steel for easy decontamination and corrosion resistance. The function test carried out at intervention area of the PIE facility showed good performance

  9. Corrosion of Nickel-Titanium Orthodontic Archwires in Saliva and Oral Probiotic Supplements

    Directory of Open Access Journals (Sweden)

    Gianluca Turco

    2017-01-01

    Full Text Available Objectives: The aim of the study was to examine how probiotic supplements affect the corrosion stability of orthodontic archwires made of nickel-titanium alloy (NiTi. Materials and Methods: Ni-Ti archwires (0.508x0.508 and having the length of 2.5 cm were tested. The archwires (composition Ni=50.4%, Ti=49.6% were uncoated, nitrified and rhodium coated. Surface microgeometry was observed by using scanning electron microscope and surface roughness was measured by profilometer through these variables: roughness average, maximum height and maximum roughness depth. Corrosion was examined by electrochemical method of cyclic polarisation. Results: Rhodium coated alloy in saliva has significantly higher general corrosion in saliva than nitrified alloy and uncoated alloy, with large effect size (p=0.027; η2=0.700. In the presence of probiotics, the result was even more pronounced (p<0.001; η2=0.936. Probiotic supplement increases general and localised corrosion of rhodium coated archwire and slightly decreases general corrosion and increases localised corrosion in uncoated archwire , while in the case of nitrified archwire the probability of corrosion is very low. The differences in surface roughness between NiTi wires before corrosion are not significant. Exposure to saliva decreases roughness average in rhodium coated wire (p=0.015; η2=0.501. Media do not significantly influence surface microgeometry in nitrified and uncoated wires. Conclusion: Probiotic supplement affects corrosion depending on the type of coating of the NiTi archwire. It increases general corrosion of rhodium coated wire and causes localised corrosion of uncoated and rhodium coated archwire. Probiotic supplement does not have greater influence on surface roughness compared to that of saliva.

  10. Electronic voltage and current transformers testing device.

    Science.gov (United States)

    Pan, Feng; Chen, Ruimin; Xiao, Yong; Sun, Weiming

    2012-01-01

    A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs) with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz). The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware.

  11. Psychometric Properties of Brief Screening Tests for Alcohol Use Disorders during Pregnancy in Argentina.

    Science.gov (United States)

    López, Mariana Beatriz; Lichtenberger, Aldana; Conde, Karina; Cremonte, Mariana

    2017-07-01

    Background  Considering the physical, mental and behavioral problems related to fetal alcohol exposure, prenatal clinical guides suggest a brief evaluation of alcohol consumption during pregnancy to detect alcohol intake and to adjust interventions, if required. Even if any alcohol use should be considered risky during pregnancy, identifying women with alcohol use disorders is important because they could need a more specific intervention than simple advice to abstain. Most screening tests have been developed and validated in male populations and focused on the long-term consequences of heavy alcohol use, so they might be inappropriate to assess consumption in pregnant women. Objective  To analyze the internal reliability and validity of the alcohol screening instruments Alcohol Use Disorders Identification Test (AUDIT), Alcohol Use Disorders Identification Test - Consumption (AUDIT-C), Tolerance, Worried, Eye-Opener, Amnesia and Cut-Down (TWEAK), Rapid Alcohol Problems Screen - Quantity Frequency (RAPS-QF) and Tolerance, Annoyed, Cut-Down and Eye-Opener (T-ACE) to identify alcohol use disorders in pregnant women. Methods  A total of 641 puerperal women were personally interviewed during the 48 hours after delivery. The receiver operating characteristics (ROC) curves and the sensitivity and specificity of each instrument using different cut-off points were analyzed. Results  All instruments showed areas under the ROC curves above 0.80. Larger areas were found for the TWEAK and the AUDIT. The TWEAK, the T-ACE and the AUDIT-C showed higher sensitivity, while the AUDIT and the RAPS-QF showed higher specificity. Reliability (internal consistency) was low for all instruments, improving when optimal cut-off points were used, especially for the AUDIT, the AUDIT-C and the RAPS-QF. Conclusions  In other cultural contexts, studies have concluded that T-ACE and TWEAK are the best instruments to assess pregnant women. In contrast, our results evidenced the low

  12. Preliminary findings on the correlation of saliva pH, buffering ...

    African Journals Online (AJOL)

    The aim of the present comparative study was to compare some salivary characteristics between exclusive waterpipe smokers (EWPS) and non-smokers. 72 males (36 EWPS) were recruited. The volume of stimulated saliva was determined and divided by the duration of saliva collection. The pH was measured directly ...

  13. Effects of different tastants on parotid saliva flow and composition

    NARCIS (Netherlands)

    Neyraud, E.; Heinzerling, C.I.; Bult, J.H.F.; Mesmin, C.; Dransfield, E.

    2009-01-01

    Saliva from parotid glands plays a role in taste perception. Parotid saliva is also stimulated by tastants. The aim of this work is to investigate the effects of different tastants on the parotid salivary response in six subjects. Five tastants were given in different concentrations in solution and

  14. 49 CFR 40.323 - May program participants release drug or alcohol test information in connection with legal...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false May program participants release drug or alcohol... the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING... information pertaining to an employee's drug or alcohol test without the employee's consent in certain legal...

  15. Apparatus for testing semiconductor devices and capacitors

    International Nuclear Information System (INIS)

    York, R.A.

    1984-01-01

    An apparatus is provided for testing semiconductor devices. The apparatus tests the impedance of the semiconductor devices in both conducting and non-conducting states to detect semiconductors whose impedance in the conducting state is too high or whose impedance in the non-conducting state is too low. The apparatus uses a battery source for low voltage d.c. The circuitry for detecting when the impedance is too high in the conducting state includes a lamp in series with the battery source and the semiconductor device, whereby the impedance of the semiconductor device determines whether sufficient current will flow through the lamp to cause the lamp to illuminate. A d.c. to d.c. converter is provided to boost the voltage from the battery source to a relatively high voltage d.c. The relatively high voltage d.c. can be connected by a switch to circuitry for detecting when the impedance of the semiconductor device in the non-conducting state is too low. The circuitry for detecting when the impedance of the semiconductor device is too low includes a resistor which senses the current flowing in the device and converts the current into a voltage proportional to the leakage current. This voltage is then compared against a fixed reference. Further circuitry is provided for providing a visual indication when the voltage representative of leakage in relation to the reference signal indicates that there is excessive current flow through the semiconductor device

  16. Breath alcohol test

    Science.gov (United States)

    ... a glass tube. The tube is filled with bands of yellow crystals. The bands in the tube change colors (from yellow to ... Results Mean With the balloon method: 1 green band means that the blood-alcohol level is 0. ...

  17. Creatine metabolism: detection of creatine and guanidinoacetate in saliva of healthy subjects.

    Science.gov (United States)

    Martínez, Lidia D; Bezard, Miriam; Brunotto, Mabel; Dodelson de Kremer, Raquel

    2016-04-01

    Creatine (Cr) plays an important role in storage and transmission of phosphate-bound energy. Cerebral creatine deficiency syndromes comprise three inherited defects in Cr biosynthesis and transport. The aim of this study was to investigate whether Cr and Guanidinoacetate (GAA) can be detected in saliva of healthy subjects and to establish the relationship between salivary and plasma levels of these molecules. An adapted gas chromatography (GC) method is described for the quantification of Cr and GAA biomarkers in saliva. Reference values were established for GAA and Cr in saliva. These values were age dependent (p= 0.001). No difference between genders was observed. We detected a difference between GAA and Cr concentrations in saliva and in plasma. The GC method for simultaneous determination of GAA and Cr in human saliva is fast, reliable, sensitive, non-invasive and precise to use as a biochemical approach in early detection of cerebral creatine deficiency syndromes. Sociedad Argentina de Investigación Odontológica.

  18. Value of Tropheryma whipplei quantitative polymerase chain reaction assay for the diagnosis of Whipple disease: usefulness of saliva and stool specimens for first-line screening.

    Science.gov (United States)

    Fenollar, Florence; Laouira, Sonia; Lepidi, Hubert; Rolain, Jean-Marc; Raoult, Didier

    2008-09-01

    Whipple disease (WD) is a chronic infectious disease caused by Tropheryma whipplei. WD DNA has been found in stool and saliva specimens from patients and asymptomatic carriers. A total of 4418 samples that were sent to our center for determination of WD were tested by a T. whipplei-specific quantitative polymerase chain reaction (PCR) based on repetitive sequences. Definite WD was diagnosed in 71 patients, including 55 patients with classic WD (defined by positive results of periodic acid-Schiff staining and/or specific immunohistochemistry of small-bowel biopsy specimens) and 16 patients with localized WD (including patients with endocarditis, neurologic infection, and uveitis). Of the persons without WD, 2.3% had stool specimens positive for T. whipplei by PCR and 0.2% had saliva specimens positive for T. whipplei by PCR. Diagnosis of WD was likely in patients with positive results of both PCR of saliva specimens and PCR of stool specimens (positive predictive value, 95.2%). When the bacterial load was >10(4) colony-forming units per g of stool, the positive predictive value was 100%. A negative result of PCR of a saliva or stool specimen had a negative predictive value of 99.2% for classic WD. For localized WD, positive results of both PCR of saliva specimens and PCR of stool specimens had a sensitivity of 58% (compared with 94% for classic WD). The positive predictive value of testing of blood, cerebrospinal fluid, and urine specimens was 100% for each, and the positive predictive value for testing of duodenal biopsy specimens was 97.5%. T. whipplei-specific quantitative PCR of saliva and stool specimens should be performed as first-line noninvasive screening for WD. When the results for both types of specimens are positive, diagnosis of classic WD should be highly suspected, especially if a high bacterial load is detected. Because PCR of saliva and stool specimens lacks sensitivity for determination of localized WD, invasive samples should be tested on the

  19. Influence of artificial saliva in biofilm formation of Candida albicans in vitro

    Directory of Open Access Journals (Sweden)

    Michelle Peneluppi Silva

    2012-02-01

    Full Text Available Due to the increase in life expectancy, new treatments have emerged which, although palliative, provide individuals with a better quality of life. Artificial saliva is a solution that contains substances that moisten a dry mouth, thus mimicking the role of saliva in lubricating the oral cavity and controlling the existing normal oral microbiota. This study aimed to assess the influence of commercially available artificial saliva on biofilm formation by Candida albicans. Artificial saliva I consists of carboxymethylcellulose, while artificial saliva II is composed of glucose oxidase, lactoferrin, lysozyme and lactoperoxidase. A control group used sterile distilled water. Microorganisms from the oral cavity were transferred to Sabouraud Dextrose Agar and incubated at 37°C for 24 hours. Colonies of Candida albicans were suspended in a sterile solution of NaCl 0.9%, and standardisation of the suspension to 106 cells/mL was achieved. The acrylic discs, immersed in artificial saliva and sterile distilled water, were placed in a 24-well plate containing 2 mL of Sabouraud Dextrose Broth plus 5% sucrose and 0.1 mL aliquot of the Candida albicans suspension. The plates were incubated at 37°C for 5 days, the discs were washed in 2 mL of 0.9% NaCl and placed into a tube containing 10 mL of 0.9% NaCl. After decimal dilutions, aliquots of 0.1 mL were seeded on Sabouraud Dextrose Agar and incubated at 37°C for 48 hours. Counts were reported as CFU/mL (Log10. A statistically significant reduction of 29.89% (1.45 CFU/mL of Candida albicans was observed in saliva I when compared to saliva II (p = 0.002, considering p≤0.05.

  20. Pengaruh (pH Saliva terhadap Terjadinya Karies Gigi pada Anak Usia Prasekolah

    Directory of Open Access Journals (Sweden)

    Made Ayu Lely

    2017-12-01

    Full Text Available AbstractDental caries is a multifactorial process that occurs through the interaction between teeth and saliva as host, the bacteria in the oral cavity, as well as easily fermented foods. Saliva is one of the factors that have a major influence on the severity of dental caries. The aim of this study was to determine the relationship of salivary pH with dental caries among 564 preschool-age children in DIY Province and Banten Province. The results showed that pH levels of the preschool-age children’saliva are more than 75% basic ranging between 6.8 to 8.0 and the highest levels are in Serang District. Index def-t in Serang District is highest (8.83 and the lowest one is in Yogyakarta City (4.97. The mean number of cavities/ decay more than missing teeth or filling teeth. The study indicates that the acidity of saliva among preschool children in the two provinces is not associated with the occurrence of dental caries.It is more likely due to the habit of drinking sweet milk or eating sticky foods.Key words: thepH of saliva, dental caries,sweet food, sticky foods, preschool childrenageAbstrakKaries gigi merupakan proses multifaktor yang terjadi melalui interaksi antara gigi dan saliva sebagai pejamu, bakteri didalam rongga mulut, serta makanan yang mudah difermentasikan. Saliva merupakan salah satu faktor yang mempunyai pengaruh besar terhadap keparahan karies gigi. Tujuan dari penelitian ini adalah untuk mengetahui pengaruh pH saliva terhadap terjadinya karies gigi pada anak usia prasekolah. Penelitian dilakukan secara potong lintang pada 564 orang anak usia prasekolah di Provinsi Daerah Istimewa Yogyakarta (Provinsi DIY dan Provinsi Banten. Hasil penelitian menunjukkan bahwa derajat keasaman (pH saliva pada anak-anak usia prasekolah lebih dari 75% bersifat basa berkisar antara 6,8-8,0 dan tertinggi di Kabupaten Serang. Indeks def-t tertinggi 8,83 di Kabupaten Serang dan yang terendah 4,97 di Kotamadya Yogyakarta. Rerata jumlah gigi berlubang

  1. Radioimmunological analysis of circadian rhythms of cortisol and melatonin in saliva

    International Nuclear Information System (INIS)

    Demel, A.W.

    1990-12-01

    Since blood cortisol (F) and melatonin (MLT) display a circadian secretion pattern and since the saliva concentration of this hormones is an excellent indicator of its blood levels the measurement of salivary F and MLT may be used for examining circadian rhythmicity. In this study the relationship between salivary F and MLT was explored. For this purpose it was necessary first to establish and validate a radioimmunoassay for F in saliva: salivary F was determined by a direct radioimmunoassay using cortisol-3-(O-carboxymethyl) oximino-(2-( 125 I)iodohistamin) as tracer and cortisol-3-CMO-BSA antiserum. The parallel measurement of F levels in saliva and serum of adults gave an excellent correlation (r=0.87, p 0.00956x ). Serum F was assayed on the Abott TDX-System using a radioimmunofluorescence method. Secondly, using this assay the circadian saliva F pattern was determined as well as the pattern of salivary MLT in 9 young, healthy volunteers. For saliva MLT estimations a previously published method was applied (Schulz et al 1990). Using a computerized program (RHYTHM) written by Eve v. Cauter (1979), the hormone data of each individuum were examined for circadian rhythmicity and its acrophase (time of occurrence of the maximum of a sinusoid fitted to the data). The F acrophase occurred between 7:00 and 12:00 h (mean: 3:33 h, SD: 104.4 min). The easy stress-free non invasive nature of saliva collection makes saliva to one of the most accessible body fluids and of high value in studying the circadian system in healthy humans as well as in infants, children, pregnant women and anaemic patients. Measurements of salivary F and MLT may help to elucidate not only the circadian rhythms of these hormones under normal and pathological conditions but it may also provide insight in physiology and pathology of the circadian system in general. (author)

  2. [The physicochemical and microbiological characteristics of saliva during and after pregnancy].

    Science.gov (United States)

    Martínez-Pabón, María C; Martínez Delgado, Cecilia M; López-Palacio, Ana M; Patiño-Gómez, Lina M; Arango-Pérez, Eduin A

    2014-01-01

    Identify the changes in some physiological and microbiological parameters in the saliva from a group of women during and after their pregnancies. Stimulated whole saliva was collected from a cohort of 35 women during their pregnancy and afterwards to determine each sample's physicochemical (secretion rate, pH and buffer capacity) and microbiological characteristics (acidogenic bacteria count). The pH and buffer capacity of saliva during pregnancy were lower than after pregnancy. There were no statistically significant changes regarding S. mutans and Lactobacillus spp. count, but a tendency towards increased values during pregnancy was noted. Changes occurring in the saliva of pregnant women can lead to an increase of risk of suffering disease affecting one's oral health, such as caries, gingivitis and periodontal disease; this could be prevented by appropriate diagnosis and dental follow-up, including education regarding pregnant women's oral health.

  3. Clinical aspects of Candida species carriage in saliva of xerotomic subjects.

    Science.gov (United States)

    Torres, S R; Peixoto, C B; Caldas, D M; Silva, E B; Magalhães, F A C; Uzeda, M; Nucci, M

    2003-10-01

    In order to investigate the clinical factors that might influence the diversity and the degree of Candida species carriage in saliva, we conducted a cross-sectional study with 133 patients with complaints of xerostomia. Anamnesis, oral examination and collection of chewing-stimulated whole saliva were performed. The samples of saliva were kept refrigerated until they were plated onto CHROMagar Candida; cfu were counted and Candida species were identified by standard methods. There was a high prevalence of mixed Candida colonization. No relationship was found between total Candida cfu counts and variables like gender, age, place of origin, underlying diseases, exposure to medications (except antibiotics), daily habits and salivary flow rates. Oral candidiasis, antibiotic exposure and dental prosthesis wearing were associated with relatively high Candida counts in saliva. Low salivary flow rates predisposed to intense colonization by C. albicans and C. parapsilosis.

  4. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection

    Directory of Open Access Journals (Sweden)

    Adrian Carrio

    2015-11-01

    Full Text Available Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results.

  5. Automated Low-Cost Smartphone-Based Lateral Flow Saliva Test Reader for Drugs-of-Abuse Detection.

    Science.gov (United States)

    Carrio, Adrian; Sampedro, Carlos; Sanchez-Lopez, Jose Luis; Pimienta, Miguel; Campoy, Pascual

    2015-11-24

    Lateral flow assay tests are nowadays becoming powerful, low-cost diagnostic tools. Obtaining a result is usually subject to visual interpretation of colored areas on the test by a human operator, introducing subjectivity and the possibility of errors in the extraction of the results. While automated test readers providing a result-consistent solution are widely available, they usually lack portability. In this paper, we present a smartphone-based automated reader for drug-of-abuse lateral flow assay tests, consisting of an inexpensive light box and a smartphone device. Test images captured with the smartphone camera are processed in the device using computer vision and machine learning techniques to perform automatic extraction of the results. A deep validation of the system has been carried out showing the high accuracy of the system. The proposed approach, applicable to any line-based or color-based lateral flow test in the market, effectively reduces the manufacturing costs of the reader and makes it portable and massively available while providing accurate, reliable results.

  6. Effects of gum chewing exercises on saliva secretion and occlusal force in community-dwelling elderly individuals: A pilot study.

    Science.gov (United States)

    Nakagawa, Kazuharu; Matsuo, Koichiro; Takagi, Daisuke; Morita, Yu; Ooka, Takafumi; Hironaka, Shouji; Mukai, Yoshiharu

    2017-01-01

    Elderly individuals face the risk of reductions in saliva secretion and occlusal force caused by systemic diseases or medications that can eventually result in malnutrition and systemic complications. We tested the hypothesis that regular gum chewing exercises (GCE) would enhance saliva secretion and occlusal force in an elderly population. A total of 12 community-dwelling elderly individuals (3 men and 9 women) participated in this study after providing informed consent. Participants carried out GCE regimens using a soft gum (GCE-S) or hard gum (GCE-H) for 2 weeks each, with a 2-week rest period between trials. Mucosal moisture on the tongue surface, resting saliva, and occlusal force were measured before and after each test gum, and changes in parameters at relevant time-points were statistically analyzed. Differences in each measurement item were assessed using the Friedman test for before and after the GCE. We used the Holm's correction for multiple comparisons if the Friedman test results were significant. The critical value for rejecting the null hypothesis was set at P GCE-S, returned to baseline levels during the rest period and significantly increased again after GCE-H. Mucosal moisture and occlusal force followed a similar trend, with a significant rise after GCE-H. The results of the present study suggest that GCE can increase resting saliva secretion and occlusal force in elderly individuals. Further investigations are required on the appropriate use of soft and hard gums to address oral frailty in elderly individuals. Geriatr Gerontol Int 2017; 17: 48-53. © 2015 The Authors. Geriatrics & Gerontology International published by Wiley Publishing Asia Pty Ltd on behalf of Japan Geriatrics Society.

  7. Sample Stability and Protein Composition of Saliva: Implications for Its Use as a Diagnostic Fluid

    Directory of Open Access Journals (Sweden)

    Han Roelofsen

    2008-01-01

    Full Text Available Saliva is an easy accessible plasma ultra-filtrate. Therefore, saliva can be an attractive alternative to blood for measurement of diagnostic protein markers. Our aim was to determine stability and protein composition of saliva. Protein stability at room temperature was examined by incubating fresh whole saliva with and without inhibitors of proteases and bacterial metabolism followed by Surface Enhanced Laser Desorption/Ionization (SELDI analyses. Protein composition was determined by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE fractionation of saliva proteins followed by digestion of excised bands and identification by liquid chromatography tandem mass spectrometry (LC-MS/MS. Results show that rapid protein degradation occurs within 30 minutes after sample collection. Degradation starts already during collection. Protease inhibitors partly prevented degradation while inhibition of bacterial metabolism did not affect degradation. Three stable degradation products of 2937 Da, 3370 Da and 4132 Da were discovered which can be used as markers to monitor sample quality. Saliva proteome analyses revealed 218 proteins of which 84 can also be found in blood plasma. Based on a comparison with seven other proteomics studies on whole saliva we identified 83 new saliva proteins. We conclude that saliva is a promising diagnostic fl uid when precautions are taken towards protein breakdown.

  8. Comparative analysis of bacterial profiles in unstimulated and stimulated saliva samples

    DEFF Research Database (Denmark)

    Belstrøm, Daniel; Holmstrup, Palle; Jensen, Allan Bardow

    2016-01-01

    BACKGROUND AND OBJECTIVE: The microbial profiles of stimulated saliva samples have been shown to differentiate between patients with periodontitis, patients with dental caries, and orally healthy individuals. Saliva was stimulated to allow for easy and rapid collection; however, microbial...

  9. Can fluconazole concentrations in saliva be used for therapeutic drug monitoring?

    NARCIS (Netherlands)

    Koks, C. H.; Crommentuyn, K. M.; Hoetelmans, R. M.; Mathôt, R. A.; Beijnen, J. H.

    2001-01-01

    The saliva/plasma concentration ratio of fluconazole was investigated in 22 HIV-1-infected individuals with an oropharyngeal Candida infection to determine whether saliva fluconazole concentrations could provide useful information for therapeutic drug monitoring in this population. Steady-state

  10. LACK OF ASSOCIATION BETWEEN HERPESVIRUS DETECTION IN SALIVA AND GINGIVITIS IN HIV‑INFECTED CHILDREN.

    Science.gov (United States)

    Otero, Renata A; Nascimento, Flávia N N; Souza, Ivete P R; Silva, Raquel C; Lima, Rodrigo S; Robaina, Tatiana F; Câmara, Fernando P; Santos, Norma; Castro, Gloria F

    2015-01-01

    The aims of this study were to compare the detection of human herpesviruses (HHVs) in the saliva of HIV-infected and healthy control children, and to evaluate associations between viral infection and gingivitis and immunodeficiency. Saliva samples were collected from 48 HIV-infected and 48 healthy control children. Clinical and laboratory data were collected during dental visits and from medical records. A trained dentist determined gingival indices and extension of gingivitis. Saliva samples were tested for herpes simplex virus types 1 and 2 (HSV-1 and HSV-2), varicella zoster virus (VZV), Epstein-Barr virus (EBV), and cytomegalovirus (CMV) by nested polymerase chain reaction assays. Thirty-five HIV-infected and 16 control children had gingivitis. Seventeen (35.4%) HIV-infected children and 13 (27%) control children were positive for HHVs. CMV was the most commonly detected HHV in both groups (HIV-infected, 25%; control, 12.5%), followed by HSV-1 (6.2% in both groups) and HSV-2 (HIV-infected, 4.2%; control, 8.3%). The presence of HHVs in saliva was not associated with the presence of gingivitis in HIV-1-infected children (p = 0.104) or healthy control children (p = 0.251), or with immunosuppression in HIV-infected individuals (p = 0.447). Gingivitis was correlated with HIV infection (p = 0.0001). These results suggest that asymptomatic salivary detection of HHVs is common in HIV-infected and healthy children, and that it is not associated with gingivitis.

  11. Comparative evaluation of shear bond strength of metallic brackets bonded with two different bonding agents under dry conditions and with saliva contamination.

    Science.gov (United States)

    Khanehmasjedi, Mashallah; Naseri, Mohammad Ali; Khanehmasjedi, Samaneh; Basir, Leila

    2017-02-01

    This study compared the shear bond strength of metallic brackets bonded with Single Bond and Assure bonding agents under dry and saliva-contamination conditions. Sixty sound premolar teeth were selected, and stainless-steel brackets were bonded on enamel surfaces with Single Bond and Assure bonding agents under dry condition or with saliva contamination. Shear bond strength values of brackets were measured in a universal testing machine. The adhesive remnant index scores were determined after debonding of the brackets under a stereomicroscope. One-way analysis of variance (ANOVA) was used to analyze bond strength. Two-by-two comparisons were made with post hoc Tukey tests (pbrackets to tooth structure were 9.29±8.56 MPa and 21.25±8.93 MPa with the use of Assure resin bonding agent under saliva-contamination and dry conditions, respectively. These values were 10.13±6.69 MPa and 14.09±6.6 MPa, respectively, under the same conditions with the use of Single Bond adhesive. Contamination with saliva resulted in a significant decrease in the bond strength of brackets to tooth structure with the application of Assure adhesive resin (pbrackets to tooth structures. Contamination with saliva significantly decreased the bond strength of Assure bonding agent compared with dry conditions. Copyright © 2016. Published by Elsevier Taiwan LLC.

  12. Alcohol Use-Related Problems Among a Rural Indian Population of West Bengal: An Application of the Alcohol Use Disorders Identification Test (AUDIT).

    Science.gov (United States)

    Barik, Anamitra; Rai, Rajesh Kumar; Chowdhury, Abhijit

    2016-03-01

    To examine alcohol use and related problems among a rural subset of the Indian population. The Alcohol Use Disorders Identification Test (AUDIT) was used as part of Health and Demographic Surveillance of 36,611 individuals aged ≥18 years. From this survey data on 3671 current alcohol users were analysed using bivariate and multivariate ordered logit regression. Over 19% of males and 2.4% of females were current alcohol users. Mean ethanol consumption on a typical drinking day among males was estimated to be higher (96.3 gm) than females (56.5 gm). Mean AUDIT score was 11 among current alcohol users. AUDIT showed in the ordered logit regression estimated alcohol use-related problems to be low among women, Scheduled Tribes and unmarried people, whereas alcohol use-related problems registered high among Muslims. This rural population appears to be in need of an effective intervention program, perhaps targeting men and the household, aimed at reducing the level of alcohol use and related problems. © The Author 2015. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  13. Sensing cocaine in saliva with attenuated total reflection infrared (ATR-IR) spectroscopy combined with a one-step extraction method

    Science.gov (United States)

    Hans, Kerstin M.-C.; Gianella, Michele; Sigrist, Markus W.

    2012-03-01

    On-site drug tests have gained importance, e.g., for protecting the society from impaired drivers. Since today's drug tests are majorly only positive/negative, there is a great need for a reliable, portable and preferentially quantitative drug test. In the project IrSens we aim to bridge this gap with the development of an optical sensor platform based on infrared spectroscopy and focus on cocaine detection in saliva. We combine a one-step extraction method, a sample drying technique and infrared attenuated total reflection (ATR) spectroscopy. As a first step we have developed an extraction technique that allows us to extract cocaine from saliva to an almost infrared-transparent solvent and to record ATR spectra with a commercially available Fourier Transform-infrared spectrometer. To the best of our knowledge this is the first time that such a simple and easy-to-use one-step extraction method is used to transfer cocaine from saliva into an organic solvent and detect it quantitatively. With this new method we are able to reach a current limit of detection around 10 μg/ml. This new extraction method could also be applied to waste water monitoring and controlling caffeine content in beverages.

  14. Effect of oil pulling on Streptococcus mutans count in plaque and saliva using Dentocult SM Strip mutans test: A randomized, controlled, triple-blind study

    Directory of Open Access Journals (Sweden)

    Asokan S

    2008-03-01

    Full Text Available Background: Oil pulling has been used extensively for many years, without scientific evidence or proof, as a traditional Indian folk remedy to prevent teeth decay, oral malodor, bleeding gums, dryness of throat and cracked lips, and for strengthening the teeth, gums, and jaws. Aims: The aim of this study was to evaluate the effect of oil pulling with sesame oil on the count of Streptococcus mutans in plaque and saliva of children, using the Dentocult SM Strip mutans test, and to compare its efficacy with that of chlorhexidine mouthwash. Materials and Methods: Twenty age-matched adolescent boys were selected based on information obtained through a questionnaire. They were divided randomly into two groups: the control or chlorhexidine group (group I and the study or oil pulling group (group II; there were ten subjects in each group. Plaque and saliva samples were collected from all the 20 subjects on the strips from the Dentocult SM kit and, after incubation, the presence of S. mutans was evaluated using the manufacturers′ chart. The study group practiced oil pulling with sesame oil and the control group used chlorhexidine mouthwash for 10 min every day in the morning before brushing. Samples were collected from both groups after 24 h, 48 h, 1 week, and 2 weeks and the efficacy of oil pulling was compared with that of chlorhexidine mouthwash. Results: There was a reduction in the S. mutans count in the plaque and saliva samples of both the study and the control groups. The reduction in the S. mutans count in the plaque of the study group was statistically significant after 1 and 2 weeks (P = 0.01 and P = 0.008, respectively; the control group showed significant reduction at all the four time points (P = 0.01, P = 0.04, P = 0.005, and P = 0.005, respectively, at 24 h, 48 h, 1 week, and 2 weeks. In the saliva samples, significant reduction in S. mutans count was seen in the control group at 48 h, 1 week, and 2 weeks (P = 0.02, P = 0.02, P = 0

  15. Effect of saliva decontamination procedures on shear bond strength of a one-step adhesive system.

    Science.gov (United States)

    Ülker, E; Bilgin, S; Kahvecioğlu, F; Erkan, A I

    2017-09-01

    To evaluate the effect of different saliva decontamination procedures on the shear bond strength of a one-step universal adhesive system (Single Bond™ Universal Adhesive, 3M ESPE, St. Paul, MN, USA). The occlusal surfaces of 75 human third molars were ground to expose dentin. The teeth were divided into the following groups: Group 1 (control group): Single Bond™ Universal Adhesive was applied to the prepared tooth according to the manufacturer's recommendations and light cured; no contamination procedure was performed. Group 2: Bonding, light curing, saliva contamination, and dry. Group 3: Bonding, light curing, saliva contamination, rinse, and dry. Group 4: After the procedure performed in Group 2, reapplication of bonding. Group 5: After the procedure performed in Group 3, reapplication of bonding. Then, composite resins were applied with cylindrical-shaped plastic matrixes and light cured. For shear bond testing, a notch-shaped force transducer apparatus was applied to each specimen at the interface between the tooth and composite until failure occurred. The data were statistically analyzed using one-way ANOVA. One-way ANOVA revealed significant differences in shear bond strength between the control group and experimental Groups 2 and 4 (P 0.05). The present in vitro study showed that water rinsing is necessary if cured adhesive resin is contaminated with saliva to ensure adequate bond strength.

  16. Composition of betel specific chemicals in saliva during betel chewing for the identification of biomarkers.

    Science.gov (United States)

    Franke, Adrian A; Mendez, Ana Joy; Lai, Jennifer F; Arat-Cabading, Celine; Li, Xingnan; Custer, Laurie J

    2015-06-01

    Betel nut chewing causes cancer in humans, including strong associations with head and neck cancer in Guam. In the search for biomarkers of betel chewing we sought to identify chemicals specific for the 3 most commonly consumed betel preparations in Guam: nut ('BN'), nut + Piper betle leaf ('BL'), and betel quid ('BQ') consisting of nut + lime + tobacco + Piper betle leaf. Chemicals were extracted from the chewing material and saliva of subjects chewing these betel preparations. Saliva analysis involved protein precipitation with acetonitrile, dilution with formic acid followed by LCMS analysis. Baseline and chewing saliva levels were compared using t-tests and differences between groups were compared by ANOVA; p < 0.05 indicated significance. Predominant compounds in chewing material were guvacine, arecoline, guvacoline, arecaidine, chavibetol, and nicotine. In chewing saliva we found significant increases from baseline for guvacine (BN, BQ), arecoline (all groups), guvacoline (BN), arecaidine (all groups), nicotine (BQ), and chavibetol (BL, BQ), and significant differences between all groups for total areca-specific alkaloids, total tobacco-specific alkaloids and chavibetol. From this pilot study, we propose the following chemical patterns as biomarkers: areca alkaloids for BN use, areca alkaloids and chavibetol for BL use, and areca alkaloids plus chavibetol and tobacco-specific alkaloids for BQ use. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Bacterial composition in whole saliva from patients with severe hyposalivation

    DEFF Research Database (Denmark)

    Belstrøm, Daniel; Holmstrup, Palle; Fiehn, Nils-Erik

    2016-01-01

    OBJECTIVE: The purpose of this study was to compare the microbiota of stimulated whole saliva samples from patients with severe hyposalivation to samples from individuals with normal whole saliva flow rates. It was hypothesized that the two groups differ with regard to salivary bacterial profiles...... with severe hyposalivation do not differ from those of individuals with normal salivary secretion, when there are virtually no untreated active caries lesions present in the oral cavity. This article is protected by copyright. All rights reserved.......OBJECTIVE: The purpose of this study was to compare the microbiota of stimulated whole saliva samples from patients with severe hyposalivation to samples from individuals with normal whole saliva flow rates. It was hypothesized that the two groups differ with regard to salivary bacterial profiles....... METHODS: This cross-sectional study included 36 participants (24 females and 12 males, mean age 58.5 years) with severe hyposalivation and 36 gender-, age- and geographically-matched participants with normal salivary secretion from the Danish Health Examination Survey (DANHES). The microbiota...

  18. Biometric identification devices -- Laboratory testing vs. real life

    International Nuclear Information System (INIS)

    Ahrens, J.S.

    1997-01-01

    For over fifteen years Sandia National Laboratories has been involved in laboratory testing of biometric identification devices. The key concept of biometric identification devices is the ability for the system to identify some unique aspect of the individual rather than some object a person may be carrying or some password they are required to know. Tests were conducted to verify manufacturer's performance claims, to determine strengths/weaknesses of devices, and to determine devices that meet the US Department of energy's needs. However, during recent field installation, significantly different performance was observed than was predicted by laboratory tests. Although most people using the device believed it operated adequately, the performance observed was over an order of magnitude worse than predicted. The search for reasons behind this gap between the predicted and the actual performance has revealed many possible contributing factors. As engineers, the most valuable lesson to be learned from this experience is the value of scientists and engineers with (1) common sense, (2) knowledge of human behavior, (3) the ability to observe the real world, and (4) the capability to realize the significant differences between controlled experiments and actual installations

  19. Breath Alcohol Ignition Interlock Devices : Policy and Implementing Implications [Mobile .MP4 (480x320/29.97fps/13.9MB)

    Science.gov (United States)

    2011-01-01

    The goal of this project is to perform a systematic review of breath alcohol ignition interlock devices (BAIID or IID) to understand how other states have integrated such systems into administrative and judicial practice and to make recommendations f...

  20. Breath Alcohol Ignition Interlock Devices : Policy and Implementing Implications [SD .MP4 (640x424/29.97fps/22.6MB)

    Science.gov (United States)

    2011-01-01

    The goal of this project is to perform a systematic review of breath alcohol ignition interlock devices (BAIID or IID) to understand how other states have integrated such systems into administrative and judicial practice and to make recommendations f...

  1. Blood Contamination in Saliva: Impact on the Measurement of Salivary Oxidative Stress Markers

    Directory of Open Access Journals (Sweden)

    Natália Kamodyová

    2015-01-01

    Full Text Available Salivary oxidative stress markers represent a promising tool for monitoring of oral diseases. Saliva can often be contaminated by blood, especially in patients with periodontitis. The aim of our study was to examine the impact of blood contamination on the measurement of salivary oxidative stress markers. Saliva samples were collected from 10 healthy volunteers and were artificially contaminated with blood (final concentration 0.001–10%. Next, saliva was collected from 12 gingivitis and 10 control patients before and after dental hygiene treatment. Markers of oxidative stress were measured in all collected saliva samples. Advanced oxidation protein products (AOPP, advanced glycation end products (AGEs, and antioxidant status were changed in 1% blood-contaminated saliva. Salivary AOPP were increased in control and patients after dental treatment (by 45.7% and 34.1%, p<0.01. Salivary AGEs were decreased in patients after microinjury (by 69.3%, p<0.001. Salivary antioxidant status markers were decreased in both control and patients after dental treatment (p<0.05 and p<0.01. One % blood contamination biased concentrations of salivary oxidative stress markers. Saliva samples with 1% blood contamination are visibly discolored and can be excluded from analyses without any specific biochemic detection of blood constituents. Salivary markers of oxidative stress were significantly altered in blood-contaminated saliva in control and patients with gingivitis after dental hygiene treatment.

  2. NÍVEIS DE TESTOSTERONA NA SALIVA E NO PLASMA SEMINAL DE REPRODUTORES SUÍNOS

    Directory of Open Access Journals (Sweden)

    Thais Schwarz Gaggini

    2016-01-01

    Full Text Available The aims of this study were evaluated testosterone levels in saliva and seminal plasma and correlate these informations with libido and sperm production of two lines of boars. The hormonal analysis was done using ELISA (Enzyme Linked Immuno Sorbent Assay and test F and Sperman correlation of SAS program was used for statistical analysis. There was no difference (P>0.05 between boar lines and testosterone levels in saliva and seminal plasma, collection length, semen volume and concentration and sperm motility and viability. Boars used in this study had libido, semen production and sperm cells considered normal and there was no difference between the lines. The results obtained can be classified as normal parameters expected in this situation.

  3. Development of a Very High Cycle Fatigue (VHCF multiaxial testing device

    Directory of Open Access Journals (Sweden)

    M. Vieira

    2016-07-01

    Full Text Available The very high cycle region of the S-N fatigue curve has been the subject of intensive research on the last years, with special focus on axial, bending, torsional and fretting fatigue tests. Very high cycle fatigue can be achieved using ultrasonic exciters which allow for frequency testing of up to 30 kHz. Still, the multiaxial fatigue analysis is not yet developed for this type of fatigue analyses, mainly due to conceptual limitations of these testing devices. In this paper, a device designed to produce biaxial fatigue testing using a single piezoelectric axial exciter is presented, as well as the preliminary testing of this device. The device is comprised of a horn and a specimen, which are both attached to the piezoelectric exciter. The steps taken towards the final geometry of the device are presented. Preliminary experimental testing of the developed device is made using thermographic imaging, strain measurements and vibration speeds and indicates good behaviour of the tested specimen.

  4. Xylitol concentrations in artificial saliva after application of different xylitol dental varnishes

    OpenAIRE

    Pereira,Agnes de Fátima Faustino; Silva,Thiago Cruvinel da; Silva,Thelma Lopes da; Caldana,Magali de Lourdes; Bastos,José Roberto Magalhães; Buzalaf,Marília Afonso Rabelo

    2012-01-01

    Objective: The present study analyzed xylitol concentrations in artificial saliva over time after application of varnishes containing 10% and 20% xylitol. Material and Methods: Fifteen bovine enamel specimens (8x4 mm) were randomly allocated to 3 groups (n=5/group), according to the type of varnish used: 10% xylitol, 20% xylitol and no xylitol (control). After varnish application (4 mg), specimens were immersed in vials containing 500 mu L of artificial saliva. Saliva samples were collected i...

  5. Determination of morphine, codeine and 6-monoacetylmorphine in saliva of substance-abuse patients using HPLC/MS methods

    Directory of Open Access Journals (Sweden)

    Milovanović Vesna

    2012-01-01

    Full Text Available Background/Aim. Saliva represents an alternative specimen for substances abuse determination in toxicology. Hence, the aim of this study was to optimize a method for saliva specimen preparation for heroin metabolites, morphine and 6-monoacetylmorphine (6-mam, and codeine determination by liquid chromatography-mass spectrometry (LC/MS, and to apply this method on saliva samples taken from the patients. Methods. Saliva specimen was prepared using liqiud/liquid extraction of morphine, codeine and 6- mam by mixture of chloroform and isopropanol (9 : 1; v/v. Extracts were analysed by HPLC/MS technique: separation column Waters Spherisorb® 5 μm, ODS2, 4.6 × 100 mm; mobile phase: ammonium acetate : acetonitile (80 : 20; v/v, mobile phase flow rate 0.3 mL/min; mass detection range: 100-400 m/z. Regression and correlation analyses were performed with the probalility level of 0.05. Concentrations of morphine, codeine and 6-mam were determined in saliva samples of the patients with “opiates” in urine identified by the test strips. Results. Calibration for each analysed substance was done in the concentration range from 0.1 to 1 mg/L and the coefficient of correlation was R2 > 0.99. We obtained following calibration curves: y = 385531x + 14584; y = 398036x + 31542; and y = 524162x - 27105, for morphine, codeine and 6-mam, respectively. Recovery for morphine and codeine determination was 99%, while for 6- mam it was 94%. Limits of detection and quantification of a proposed method were 0.01 mg/L and 0.05 mg/L, respectively. Concentration of morphine in the saliva of the heroin users ranged between 0.54 and 5.82 mg/L, concentration of codeine between 0.05 and 5.33, and 6-mam between 0.01 and 0.68 mg/L. A statistically significant correlation between codeine and 6-mam concentrations was obtained. Conclusion. A proposed HPLC/MS method for morphine, codeine and 6-mam determination in saliva is accurate, simple, cheap and suitable for routine analysis and

  6. Antimicrobial defense systems in saliva

    NARCIS (Netherlands)

    van 't Hof, W.; Veerman, E.C.I.; Nieuw Amerongen, A.V.; Ligtenberg, A.J.M.; Ligtenberg, A.J.M.; Veerman, E.C.I.

    2014-01-01

    The oral cavity is one of the most heavily colonized parts of our body. The warm, nutrient-rich and moist environment promotes the growth of a diverse microflora. One of the factors responsible for the ecological equilibrium in the mouth is saliva, which in several ways affects the colonization and

  7. Antialarmin effect of tick saliva during the transmission of Lyme disease

    NARCIS (Netherlands)

    Marchal, Claire; Schramm, Frederic; Kern, Aurélie; Luft, Benjamin J.; Yang, Xiaohua; Schuijt, Tim J.; Hovius, Joppe W.; Jaulhac, Benoît; Boulanger, Nathalie

    2011-01-01

    Tick saliva has potent immunomodulatory properties. In arthropod-borne diseases, this effect is largely used by microorganisms to increase their pathogenicity and to evade host immune responses. We show that in Lyme borreliosis, tick salivary gland extract and a tick saliva protein, Salp15, inhibit

  8. Family Meal Frequency and Alcohol and Tobacco Use in Adolescence: Testing Reciprocal Effects

    Science.gov (United States)

    White, James; Halliwell, Emma

    2011-01-01

    This longitudinal study tested the direction of associations between family meals and alcohol and tobacco consumption during early adolescence. We examined family meal frequency, family connectedness, alcohol (binge drinking, drunkenness), and tobacco consumption (past year, daily frequency) in 671 adolescents (51% women; mean age, Wave 1 = 14.05…

  9. An Optical Sensor with Polyaniline-Gold Hybrid Nanostructures for Monitoring pH in Saliva

    Directory of Open Access Journals (Sweden)

    Chongdai Luo

    2017-03-01

    Full Text Available Saliva contains important personal physiological information that is related to some diseases, and it is a valuable source of biochemical information that can be collected rapidly, frequently, and without stress. In this article, we reported a new and simple localized surface plasmon resonance (LSPR substrate composed of polyaniline (PANI-gold hybrid nanostructures as an optical sensor for monitoring the pH of saliva samples. The overall appearance and topography of the substrates, the composition, and the wettability of the LSPR surfaces were characterized by optical and scanning electron microscope (SEM images, infrared spectra, and contact angles measurement, respectively. The PANI-gold hybrid substrate readily responded to the pH. The response time was very short, which was 3.5 s when the pH switched from 2 to 7, and 4.5 s from 7 to 2. The changes of visible-near-infrared (NIR spectra of this sensor upon varying pH in solution showed that—for the absorption at given wavelengths of 665 nm and 785 nm—the sensitivities were 0.0299 a.u./pH (a.u. = arbitrary unit with a linear range of pH = 5–8 and 0.0234 a.u./pH with linear range of pH = 2–8, respectively. By using this new sensor, the pH of a real saliva sample was monitored and was consistent with the parallel measurements with a standard laboratory method. The results suggest that this novel LSPR sensor shows great potential in the field of mobile healthcare and home medical devices, and could also be modified by different sensitive materials to detect various molecules or ions in the future.

  10. An Optical Sensor with Polyaniline-Gold Hybrid Nanostructures for Monitoring pH in Saliva.

    Science.gov (United States)

    Luo, Chongdai; Wang, Yangyang; Li, Xuemeng; Jiang, Xueqin; Gao, Panpan; Sun, Kang; Zhou, Jianhua; Zhang, Zhiguang; Jiang, Qing

    2017-03-17

    Saliva contains important personal physiological information that is related to some diseases, and it is a valuable source of biochemical information that can be collected rapidly, frequently, and without stress. In this article, we reported a new and simple localized surface plasmon resonance (LSPR) substrate composed of polyaniline (PANI)-gold hybrid nanostructures as an optical sensor for monitoring the pH of saliva samples. The overall appearance and topography of the substrates, the composition, and the wettability of the LSPR surfaces were characterized by optical and scanning electron microscope (SEM) images, infrared spectra, and contact angles measurement, respectively. The PANI-gold hybrid substrate readily responded to the pH. The response time was very short, which was 3.5 s when the pH switched from 2 to 7, and 4.5 s from 7 to 2. The changes of visible-near-infrared (NIR) spectra of this sensor upon varying pH in solution showed that-for the absorption at given wavelengths of 665 nm and 785 nm-the sensitivities were 0.0299 a.u./pH (a.u. = arbitrary unit) with a linear range of pH = 5-8 and 0.0234 a.u./pH with linear range of pH = 2-8, respectively. By using this new sensor, the pH of a real saliva sample was monitored and was consistent with the parallel measurements with a standard laboratory method. The results suggest that this novel LSPR sensor shows great potential in the field of mobile healthcare and home medical devices, and could also be modified by different sensitive materials to detect various molecules or ions in the future.

  11. Quantity of Candida Colonies in Saliva: 
A Diagnostic Evaluation for Oral Candidiasis.

    Science.gov (United States)

    Zhou, Pei Ru; Hua, Hong; Liu, Xiao Song

    To investigate the relationship between the quantity of Candida colonies in saliva and oral candidiasis (OC), as well as to identify the threshold for distinguishing oral candidiasis from healthy carriage. A diagnostic test was conducted in 197 patients with different oral problems. The diagnosis of OC was established based on clinical features. Whole saliva samples from the subjects were cultured for Candida species. Receiver operating characteristic (ROC) curve analysis was used in this study. OC patients had significantly more Candida colony-forming units per millilitre saliva (795 cfu/ml) than asymptomatic carriers (40 cfu/ml; P candidiasis, the quantity of Candida colonies differed. The number of Candida colonies in pseudomembranous type was significantly higher than that in the erythematous type (P < 0.05). Candida albicans was the predominant species of Candida. The cut-off point with the best fit for OC diagnosis was calculated to be 266 cfu/ml. The sensitivity and specificity were 0.720 and 0.825, respectively. Analysis of the ROC curve indicated that Candida colonies had a high diagnostic value for OC, as demonstrated by the area under the curve (AUC = 0.873). Based on this study, the value of 270 cfu/ml was considered a threshold for distinguishing OC from carriage.

  12. 49 CFR 40.15 - May an employer use a service agent to meet DOT drug and alcohol testing requirements?

    Science.gov (United States)

    2010-10-01

    ... drug and alcohol testing requirements? 40.15 Section 40.15 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Employer Responsibilities § 40.15 May an employer use a service agent to meet DOT drug and alcohol testing requirements? (a...

  13. Multiple sclerosis test or the 4 humors: cerebrospinal fluid serum, tears and saliva

    International Nuclear Information System (INIS)

    Oehninger Gatti, C.; Buzo Del Puerto, R.; Chouza Antelo, C.; Scotti Bianchi, C.; Cibils, D.; Alcantara Pelaez, J.; Gomez, A.; Heuguerot Oliveira, C.

    1994-01-01

    4 were studied biological fluids easily accessible to the immune exploration (cerebrospinal fluid, serum, tears and saliva) in 25 patients with Multiple Sclerosis (MS) during a push clinical disease. The level of interleukin-2 receptor soluble (RsIL-2) was significantly increased by at least 3 of these 4 fluids, compared with normal controls. The sensitivity and specificity of its determination for the diagnosis of the condition was higher than other immunochemical parameters, oligoclonal distribution (OD) of immunoglobulin (Ig) light chain imbalance-and-evoked electrophysiological studies. This method is used to establish a more accurate diagnosis of Multiple Sclerosis as well as to monitor its biological activity with nuclear magnetic resonance (NMR) (Author) [es

  14. Effects of isoflurane anesthesia and pilocarpine on rat parotid saliva flow

    DEFF Research Database (Denmark)

    Knudsen, Jacob Dronninglund; Nauntofte, Birgitte; Josipovic, M

    2011-01-01

    rats was 50% slower than that of the sham-irradiated rats. In conclusion, 1.5% isoflurane was found to be a good compromise between proper anesthesia and isoflurane-induced inhibition of saliva secretion. Pilocarpine induces saliva secretion in a dose-dependent matter, with supra-maximal stimulation...

  15. Kinetics of Anti-Phlebotomus perniciosus Saliva Antibodies in Experimentally Bitten Mice and Rabbits.

    Directory of Open Access Journals (Sweden)

    Inés Martín-Martín

    Full Text Available Sand flies are hematophagous arthropods that act as vectors of Leishmania parasites. When hosts are bitten they develop cellular and humoral responses against sand fly saliva. A positive correlation has been observed between the number of bites and antibody levels indicating that anti-saliva antibody response can be used as marker of exposure to sand flies. Little is known about kinetics of antibodies against Phlebotomus perniciosus salivary gland homogenate (SGH or recombinant salivary proteins (rSP. This work focused on the study of anti-P. perniciosus saliva antibodies in sera of mice and rabbits that were experimentally exposed to the bites of uninfected sand flies.Anti-saliva antibodies were evaluated by ELISA and Western blot. In addition, antibody levels against two P. perniciosus rSP, apyrase rSP01B and D7 related protein rSP04 were determined in mice sera. Anti-saliva antibody levels increased along the immunizations and correlated with the number of sand fly bites. Anti-SGH antibody levels were detected in sera of mice five weeks after exposure, and persisted for at least three months. Anti-apyrase rSP01B antibodies followed similar kinetic responses than anti-SGH antibodies while rSP04 showed a delayed response and exhibited a greater variability among sera of immunized mice. In rabbits, anti-saliva antibodies appeared after the second week of exposure and IgG antibodies persisted at high levels, even 7 months post-exposure.Our results contributed to increase the knowledge on the type of immune response P. perniciosus saliva and individual proteins elicited highlighting the use of rSP01B as an epidemiological marker of exposure. Anti-saliva kinetics in sera of experimentally bitten rabbits were studied for the first time. Results with rabbit model provided useful information for a better understanding of the anti-saliva antibody levels found in wild leporids in the human leishmaniasis focus in the Madrid region, Spain.

  16. The current situation and development of medical device testing institutes in China.

    Science.gov (United States)

    Yang, Xiaofang; Mu, Ruihong; Fan, Yubo; Wang, Chunren; Li, Deyu

    2017-04-01

    This article analyses the current situation and development of Chinese medical device testing institutes from the perspectives of the two most important functions - testing functions and medical device standardization functions. Areas Covered: The objective of the Chinese government regulations for medical device industry is to ensure the safety and effectiveness of medical devices for Chinese patients. To support the regulation system, the Chinese government has established medical device testing institutes at different levels for example, the national, provincial, and municipal levels. These testing institutes also play an important role in technical support during medical device premarket registration and post market surveillance, they are also the vital practitioners of Chinese medical device standardization. Expert Commentary: Chinese medical device testing institutes are technical departments established by government, and serve the regulatory functions of government agency. In recent years, with the rapid development of medical device industry as well as constantly increasing international and domestic medical device market, the importance of medical device testing institute is more prominent, However, there are still some problems unsolved, such as their overall capacity remains to be improved, construction of standardization is to be strengthened, etc.

  17. Radioimmunological analysis of circadian rhythms of cortisol and melatonin in saliva

    International Nuclear Information System (INIS)

    Demel, A.W.

    1990-12-01

    Since blood cortisol (F) and melatonin (MLT) display a circadian secretion pattern and since the saliva concentration of this hormones is an excellent indicator of its blood levels the measurement of salivary F and MLT may be user for examining circadian rhythmicity. In this study the relationship between salivary F and MLT was explored. For this purpose it was necessary first to establish and validate a radioimmunoassay for F in saliva: salivary F was determined by a direct radioimmunoassay using cortisol-3-(O-carb oxymethyl) oximino-(2-( 125 I)iodohistamin) as tracer and cortisol-3-CMO-BSA antiserum. The parallel measurement of F levels in saliva and serum of adults gave an excellent correlation (r=0.87, p 0.00956x ). Serum F was assayed on the Abott TDX-System using a radioimmunofluorescence method. Secondly, using this assay the circadian saliva F pattern was determined as well as the pattern of salivary MLT in 9 young, healthy volunteers. For saliva MLT estimations a previously published method was applied (SCHULZ et al 1990). Using a computerized program (RHYTHM) written by EVE v. CAUTER (1979), the hormone data of each individuum were examined for circadian rhythmicity and its acrophase (time of occurence of the maximum of a sinusoid fitted to the data). The F acrophase occured between 7:00 and 12:00 h (Mean: 3:33 h, SD: 104.4 min). The easy stress-free non invasive nature of saliva collection makes saliva to one of the most accessible body fluids and of high value in studying the circadian system in healthy humans as well as in infants, children, pregnant women and anaemic patients. Measurements of salivary F and MLT may help to elucidate not only the circadian rhythms of these hormones under normal and pathological conditions but it may also provide insight in physiology and pathology of the circadian system in general. (author)

  18. Saliva secretion difference before and after rinsing with baking soda on menopause women

    Directory of Open Access Journals (Sweden)

    Dewi Anggraeni

    2007-03-01

    Full Text Available Menopause women can experience a decrease in saliva secretion (decrease. To understand the clear picture about saliva secretion, the volume, flow rate, pH and viscosity were then measured. The aim of this research was to obtain a picture about the difference of saliva secretion before and after rinsing with baking soda on menopause women. The type of the research used was a laboratory quasi-experiment with comparative descriptive form. The technique used in this research is the survey method, and samples were taken using the multistage cluster random sampling method, and t-student statistical analysis. This research was conducted with the saliva collected with spitting method on 45 menopause women. The results show that the average volume, flow rate, pH and viscosity before rinsing with baking soda was 1.79 ml, 0.18 ml/minute, 7.40 and 0.81 mm2/second. The average volume, flow rate, pH and viscosity after rinsing with baking soda were 2.66 ml; 0.27 ml/minute; 8.67 and 0.78 mm2/second. Statistical analysis t-student on α = 0.05 shows volume changes, flow rate, pH and saliva viscosity before and after rinsing with baking soda was 0.873; 0.086; 1.273 and 0.037 respectively. The conclusion shows a significant difference between saliva secretion before and after rinsing with baking soda, and saliva secretion after rinsing with baking soda on menopause women.

  19. Erosive potential of saliva stimulating tablets with and without fluoride in irradiated head and neck cancer patients

    DEFF Research Database (Denmark)

    Lajer, Christel; Buchwald, Christian; Nauntofte, Birgitte

    2009-01-01

    stimulated saliva without fluoride, and with fluoride. Saliva pH was determined without loss of CO(2) and in combination with inorganic measures used to calculate the degree of saturation of hydroxyapatite (HAp) and fluorapatite (FAp). EP was determined directly in all saliva samples by monitored dissolution......BACKGROUND: Patients irradiated in the head and neck region often suffer from severe dry mouth and use acidic saliva stimulating products, which may cause erosion of teeth. PURPOSE: To determine saliva stimulating effects and erosive potential (EP) of acidic saliva stimulating tablets (Xerodent...

  20. Salivary exoglycosidases as markers of alcohol dependence.

    Science.gov (United States)

    Waszkiewicz, Napoleon; Chojnowska, Sylwia; Zalewska, Anna; Zwierz, Krzysztof; Szulc, Agata; Szajda, Sławomir Dariusz

    2014-01-01

    Some salivary markers of alcohol abuse/dependence have been proposed so far: aminotransferases, gamma-glutamyltransferase, ethanol, ethyl glucuronide, ethyl sulfate, sialic acid, β-hexosaminidase A, oral peroxidase, methanol, diethylene/ethylene glycol, α-amylase, clusterin, haptoglobin, heavy/light chains of immunoglobulins and transferrin. To investigate the effect of chronic alcohol drinking and smoking on the activity (pKat/ml) and output (pKat/min) of salivary lysosomal exoglycosidases: α-fucosidase (FUC), α-mannosidase (MAN), β-galactosidase (GAL), and β-glucuronidase (GLU), and their applicability as markers of alcohol dependence. The activity of FUC, MAN, GAL and GLU was measured colorimetrically in the saliva of healthy social drinkers, alcohol-dependent non-smokers and alcohol-dependent smokers. We observed an increased salivary activity of FUC, GAL, GLU and MAN, as well as an increased output of GAL and GLU, in comparison with controls. The highest increase in the activity/output was found in salivary GLU and MAN (GLU, even 7- to 18-fold), and the least in GAL. We found an excellent sensitivity and specificity and a high accuracy (measured by the area under the ROC curve) for salivary FUC, GLU and MAN activities. The salivary GLU activity positively correlated with the number of days of last alcohol intoxication. Salivary activity of FUC, GAL and MAN, but not GLU, positively correlated with the periodontal parameters such as gingival index and papilla bleeding index. Although we found an excellent sensitivity and specificity as well as a high accuracy for the salivary activity of FUC, GLU and MAN, the GLU activity seems to be mostly applicable as a marker of chronic alcohol drinking (alcohol dependence). © The Author 2014. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  1. Dissociation between wanting and liking for alcohol and caffeine: A test of the Incentive Sensitisation Theory.

    Science.gov (United States)

    Arulkadacham, Lilani J; Richardson, Ben; Staiger, Petra K; Kambouropoulos, Nicolas; O'Donnell, Renée L; Ling, Mathew

    2017-07-01

    Limited human studies have directly tested the dissociation between wanting and liking with human substance users, a core tenet of the Incentive Sensitisation Theory (IST). The aim of this study is to test the dissociation between wanting and liking in humans across two commonly used licit substances, alcohol and caffeine. The STRAP-R (Sensitivity To Reinforcement of Addictive and other Primary Rewards) questionnaire was administered to 285 alcohol users (mean age=33.30, SD= 8.83) and 134 coffee users (mean age=33.05, SD=8.10) ranging in their levels of substance use to assess wanting and liking. Findings showed that in high risk alcohol users wanting may drive alcohol consumption more so than liking, compared with low risk alcohol users. However, wanting and liking did not significantly dissociate as alcohol consumption increased. These findings partially support IST. Additionally, IST was not supported in coffee users. It is possible that caffeine functions differently at the neurological level compared with alcohol, perhaps explaining the lack of dissociation emerging in coffee users as caffeine use increased. Nevertheless, the current study makes several contributions to IST research. Future studies should focus on utilising the STRAP-R with a clinically dependent sample to test the dissociation between wanting and liking.

  2. Testing Framework for Mobile Device Forensics Tools

    Directory of Open Access Journals (Sweden)

    Maxwell Anobah

    2014-09-01

    Full Text Available The proliferation of mobile communication and computing devices, in particular smart mobile phones, is almost paralleled with the increasing number of mobile device forensics tools in the market. Each mobile forensics tool vendor, on one hand claims to have a tool that is best in terms of performance, while on the other hand each tool vendor seems to be using different standards for testing their tools and thereby defining what support means differently. To overcome this problem, a testing framework based on a series of tests ranging from basic forensics tasks such as file system reconstruction up to more complex ones countering antiforensic techniques is proposed. The framework, which is an extension of an existing effort done in 2010, prescribes a method to clearly circumscribe the term support into precise levels. It also gives an idea of the standard to be developed and accepted by the forensic community that will make it easier for forensics investigators to quickly select the most appropriate tool for a particular mobile device.

  3. Interleukin-6 and neopterin levels in the serum and saliva of patients with Lichen planus and oral Lichen planus.

    Science.gov (United States)

    Abdel-Haq, Ayman; Kusnierz-Cabala, Beata; Darczuk, Dagmara; Sobuta, Eliza; Dumnicka, Paulina; Wojas-Pelc, Anna; Chomyszyn-Gajewska, Maria

    2014-11-01

    Lichen planus together with its oral variant is a chronic, inflammatory disease of the skin and the mucosa of unclear aetiology and with an unpredictable course that still poses a major problem in terms of diagnosis and treatment. The objective of this study was to assess the concentrations of interleukin-6 (IL-6) and neopterin in saliva and serum of patients with lichen planus (including reticular and erosive form of oral lichen planus) and to compare them with the concentrations observed in healthy controls. The study material comprised serum and saliva samples from 56 patients diagnosed with lichen planus and 56 healthy volunteers. The ELISA test was used to measure concentrations of IL-6 and neopterin in the serum and saliva of the study participants. The concentrations of IL-6 in saliva and serum of patients with lichen planus were significantly higher than in controls (P = 0.0002; P oral lichen planus had significantly higher IL-6 concentrations in their saliva compared to patients with reticular form of disease (P = 0.01). The concentrations of neopterin were significantly higher in the serum but not in saliva of lichen planus patients vs. controls (P lichen planus as well as the salivary concentrations of IL-6. The differences observed in IL-6 levels in patients with erosive-atrophic forms of oral lichen planus may indicate a substantial role played by the cytokine in the disease. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Cigarette smoke-exposed saliva suppresses cellular and humoral immune responses in an animal model

    International Nuclear Information System (INIS)

    Jafarzadeh, A.; Bakhshi, H.; Rezayati, M.T.; Nemati, M.

    2009-01-01

    To evaluate the effects of cigarette smoke (CS)-exposed saliva on cellular and antibody responses in an animal model. The stimulatory and non-stimulatory saliva samples were collected from 10 healthy subjects and were then exposed to CS for 20 or 80 minutes. The CS-exposed saliva samples were administrated intraperitoneally (i.p) to male Balb/c mice. Then the delayed type hypersensitivity (DTH) and antibody responses to sheep red blood cell (SRBC) was assessed. Moreover, the total white blood cells (WBC) counts and the blood lymphocytes counts were determined. The mean of DTH responses of animal groups received 20 minutes or 80 minutes CS-exposed saliva samples was significantly lower than that observed in control group. Moreover, The mean titer of anti-SRBC antibody was significantly lower in animal groups who received 80 minutes CS-exposed stimulatory or non-stimulatory saliva as compared to control group (P<0.04 and P<0.002, respectively). The mean counts of blood lymphocytes in 80 minutes CS exposed-stimulatory saliva group was also significantly lower as compared to control group (P<0.05). These results show that the CS-exposed saliva samples have profound suppressive effects on both cellular and humoral immune response in a mouse animal model (JPMA 59:760; 2009). (author)

  5. The effect of saliva composition on texture perception of semi-solids

    NARCIS (Netherlands)

    Engelen, L.; Keybus, P.A.M. van den; Wijk, R.A. de; Veerman, E.C.I.; Amerongen, A.V.N.; Bosman, F.; Prinz, J.F.; Bilt, A. van der

    2007-01-01

    Saliva is expected to be of significance for the perception of food stimuli in the mouth. Mixing the food with saliva, including breakdown and dilution, is considered to be of large importance for semi-solids as these products are masticated without chewing. It is known that there are large

  6. Kontrasepsi Hormonal Meningkatkan Kadar α-Amylase Saliva

    Directory of Open Access Journals (Sweden)

    Juni Handajani

    2014-06-01

    Full Text Available Salivary α-amylase atau α-amylase saliva (SAA adalah salah satu enzim dalam saliva yang berperan penting pada inisiasi digesti karbohidrat dan fungsi interaksi bakteri. Kontrasepsi hormonal sangat populer di Indonesia untuk mencegah kehamilan. Penelitian ini bertujuan untuk mengetahui kadar SAA wanita pemakai kontrasepsi pil dan suntik. Subjek penelitian sebanyak 30 perempuan usia 20-35 tahun. Prosedur penelitian telah mendapat persetujuan dari Komite Etik Fakultas Kedokteran Universitas Gadjah Mada Yogyakarta. Subjek dibagi menjadi 3 kelompok (pemakai kontrasepsi pil, suntik, dan kontrol, masing-masing 10 perempuan. Kriteria subjek antara lain subjek sehat, tidak menggunakan alat ortodontik, protesa atau mahkota, serta menggunakan kontrasepsi hormonal lebih dari 3 bulan. Sampel saliva dikumpulkan pada sore hari (16.00-18.00 WIB selama 1 menit dengan metode tanpa stimulasi. Kadar tingkat SAA diukur menggunakan ELISA kit (Salimetrics LLC dengan Optical Density (OD pada 405 nm. Data dianalisis menggunakan ANOVA (p<0,05. Hasil penelitian menunjukkan kadar SAA tertinggi pada perempuan pemakai kontrasepsi  pil dan ada perbedaan yang signifikan diantara tiga kelompok. Disimpulkan bahwa kontrasepsi hormonal meningkatkan kadar SAA. Hormonal Contraceptive Increased The Level of Salivary Α-Amylase. Salivary α-amylase (SAA is one of the most important enzymes in saliva. This enzyme was mainly involved in the initiation of the digestion of starch in the oral cavity and has significant bacterial interactive function. Hormonal contraceptives are very popular in Indonesia to avoid pregnancy. This study aimed to evaluate the level of SAA in woman who taking pill and by injection contraceptives. Thirty women were in subjects, 20-35 years old, approval ethical clearance from Ethic Committee Medical Faculty of Gadjah Mada University, Yogyakarta Indonesia. Subjects were divided into three groups (taking pill contraceptive, by injection contraceptive and

  7. Saliva/serum ghrelin, obestatin and homocysteine levels in patients with ischaemic heart disease

    Science.gov (United States)

    Kilic, Nermin; Dagli, Necati; Aydin, Suleyman; Erman, Fazilet; Bek, Yuksel; Akin, Okhan; Kilic, SS; Erdemli, Haci Kemal; Alacam, Hasan

    2017-01-01

    Summary Background: We aimed to compare ghrelin, obestatin, homocysteine (Hcy), vitamin B12 and folate levels in the serum and saliva of ischaemic heart disease patients. Methods: Serum and saliva were collected from 33 ischaemic heart disease (IHD) patients and 28 age- and body mass index-matched healthy individuals. Levels of acylated and desacylated ghrelin, obestatin and Hcy were determined using the ELISA method. Results: Acylated ghrelin, desacylated ghrelin and obestatin levels in the saliva were found to be higher than those in the serum of the control group, while acylated and desacylated ghrelin levels in the saliva were significantly lower than those in the serum. Obestatin levels were higher in IHD patients (p = 0.001). Saliva and serum vitamin B12 and folate levels in IHD patients were significantly lower than in the control group (p = 0.001). Conclusions: It was determined that serum ghrelin levels increased in ischaemic heart disease patients, while serum levels of obestatin decreased. PMID:28759087

  8. Effects of glycemic control on saliva flow rates and protein composition in non-insulin-dependent diabetes mellitus.

    Science.gov (United States)

    Dodds, M W; Dodds, A P

    1997-04-01

    The objective of this study was to determine whether improvements in the level of diabetic control in a group of subjects with poorly controlled non-insulin-dependent diabetes mellitus influence salivary output and composition. Repeated whole unstimulated and stimulated parotid saliva samples were collected from diabetic patients attending an outpatient diabetes education program and a matched nondiabetic control group. Saliva was analyzed for flow rates, parotid protein concentration and composition, and amylase activity. Subjective responses to questions about salivary hypofunction were tested. There were no significant differences in whole unstimulated and stimulated parotid flow rates or stimulated parotid protein concentration and composition between diabetics and the control group. Amylase activity was higher in diabetics and decreased with improved glycemic control. Subjects reporting taste alterations had higher mean blood glucose levels than subjects with normal taste sensation. Poorly controlled non-insulin-dependent diabetes mellitus has no influence on saliva output, although amylase activity may be elevated, and there may be taste alterations.

  9. Evaluation of the Secretor Status of ABO Blood Group Antigens in Saliva among Southern Rajasthan Population Using Absorption Inhibition Method.

    Science.gov (United States)

    Metgud, Rashmi; Khajuria, Nidhi; Mamta; Ramesh, Gayathri

    2016-02-01

    The ABO blood group system was the significant element for forensic serological examination of blood and body fluids in the past before the wide adaptation of DNA typing. A significant proportion of individuals (80%) are secretors, meaning that antigens present in the blood are also found in other body fluids such as saliva. Absorption inhibition is one such method that works by reducing strength of an antiserum based on type and amount of antigen present in the stains. To check the efficacy of identifying the blood group antigens in saliva and to know the secretor status using absorption inhibition method among southern Rajasthan population. Blood and saliva samples were collected from 80 individuals comprising 20 individuals in each blood group. The absorption inhibition method was used to determine the blood group antigens in the saliva and then the results were correlated with the blood group of the collected blood sample. The compiled data was statistically analysed using chi-square test. Blood groups A & O revealed 100% secretor status for both males and females. While blood groups B and AB revealed 95% secretor status. Secretor status evaluation of the ABO blood group antigen in saliva using absorption inhibition method can be a useful tool in forensic examination.

  10. Erosive potential of saliva stimulating tablets with and without fluoride in irradiated head and neck cancer patients

    International Nuclear Information System (INIS)

    Lajer, Christel; Buchwald, Christian; Nauntofte, Birgitte; Specht, Lena; Bardow, Allan; Jensdottir, Thorbjoerg

    2009-01-01

    Background: Patients irradiated in the head and neck region often suffer from severe dry mouth and use acidic saliva stimulating products, which may cause erosion of teeth. Purpose: To determine saliva stimulating effects and erosive potential (EP) of acidic saliva stimulating tablets (Xerodent TM ) with and without fluoride in irradiated head and neck cancer patients. Materials and method: Nineteen irradiated patients (median age 57 years) sucked Xerodent TM tablets with and without fluoride. Saliva collections were divided into three 10-min sessions in the sequence: unstimulated whole saliva, Xerodent TM stimulated saliva without fluoride, and with fluoride. Saliva pH was determined without loss of CO 2 and in combination with inorganic measures used to calculate the degree of saturation of hydroxyapatite (HAp) and fluorapatite (FAp). EP was determined directly in all saliva samples by monitored dissolution of HAp crystals. Results: Saliva flow rates increased significantly (15-fold) when sucking both tablets (p TM with and without fluoride were evaluated as non-erosive, however, for additional caries protection the fluoride variant is preferable.

  11. DNA extraction from human saliva deposited on skin and its use in forensic identification procedures Extração de DNA de saliva humana depositada sobre a pele e sua aplicabilidade aos processos de identificação forense

    Directory of Open Access Journals (Sweden)

    Evelyn Anzai-Kanto

    2005-09-01

    Full Text Available Saliva is usually deposited in bite marks found in many homicides, assault and other criminal cases. In the present study, saliva obtained from volunteers was deposited on skin and recovered for DNA extraction and typing in order to evaluate its usefulness for practical case investigation and discuss the contribution of forensic dentistry to saliva DNA typing. Twenty saliva samples were colleted from different donors and used as suspects' samples. Five of these samples were randomly selected and deposited (250 µl on arm skin. Saliva was collected from skin using the double swab technique. DNA from saliva and skin-deposited saliva samples was extracted by the phenol-chloroform method. DNA samples were amplified by PCR for DNA typing using a set of 15 STRs. The recovery of DNA from saliva deposited in the skin was 14 to 10 times lower than DNA quantity from saliva samples. DNA typing was demonstrated in 4 of 5 deposited saliva samples, the likelihood ratios estimated for these samples based on data of the Brazilian population were 1:11, 1:500, 1:159.140 and 1:153.700.123. Our results indicate that standardized procedures used for DNA collection and extraction from skin-deposited saliva can be used as a method to recover salivary DNA in criminal cases. However, it is important to observe that DNA recovery in forensic samples can be difficult. This study suggests that the analysis of saliva deposited on skin be incorporated into a criminal investigation since it may have great discriminatory power.A saliva é usualmente depositada em marcas de mordida encontradas em homicídios, agressões e outros crimes. Neste estudo, a saliva obtida de voluntários foi depositada na pele, recuperada para extração e tipagem do DNA, para avaliação de sua utilização e sua contribuição na odontologia legal. Vinte amostras de saliva foram coletadas de diferentes doadores e utilizadas como amostras de suspeitos. Cinco dessas amostras foram sorteadas e

  12. Testing Mediators of Reduced Drinking for Veterans in Alcohol Care Management.

    Science.gov (United States)

    Moskal, Dezarie; Maisto, Stephen A; Possemato, Kyle; Lynch, Kevin G; Oslin, David W

    2018-03-26

    Alcohol Care Management (ACM) is a manualized treatment provided by behavioral health providers working in a primary care team aimed at increasing patients' treatment engagement and decreasing their alcohol use. Research has shown that ACM is effective in reducing alcohol consumption; however, the mechanisms of ACM are unknown. Therefore, the purpose of this study is to examine the mechanisms of change in ACM in the context of a randomized clinical trial evaluating the effectiveness of ACM. This study performed secondary data analysis of existing data from a larger study that involved a sample of U.S. veterans (N = 163) who met criteria for current alcohol dependence. Upon enrollment into the study, participants were randomized to receive either ACM or standard care. ACM was delivered in-person or by telephone within the primary care clinic and focused on the use of oral naltrexone and manualized psychosocial support. According to theory, we hypothesized several ACM treatment components that would mediate alcohol consumption outcomes: engagement in addiction treatment, reduced craving, and increased readiness to change. Parallel mediation models were performed by the PROCESS macro Model 4 in SPSS to test study hypotheses. The institutional review boards at each of the participating facilities approved all study procedures before data collection. As hypothesized, results showed that treatment engagement mediated the relation between treatment and both measures of alcohol consumption outcomes, the percentage of alcohol abstinent days, and the percentage of heavy drinking days. Neither craving nor readiness to change mediated the treatment effect on either alcohol consumption outcome. Findings suggest that ACM may be effective in changing drinking patterns partially due to an increase in treatment engagement. Future research may benefit from evaluating the specific factors that underlie increased treatment engagement. The current study provides evidence that alcohol

  13. 49 CFR Appendix F to Part 40 - Drug and Alcohol Testing Information that C/TPAs May Transmit to Employers

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Drug and Alcohol Testing Information that C/TPAs... Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Pt. 40, App. F Appendix F to Part 40—Drug and Alcohol Testing Information that C/TPAs May Transmit to Employers 1. If you...

  14. Sensing cocaine in saliva with infrared laser spectroscopy

    Science.gov (United States)

    Hans, Kerstin M.-C.; Müller, Matthias; Gianella, Michele; Wägli, Ph.; Sigrist, Markus W.

    2013-02-01

    Increasing numbers of accidents caused by drivers under the influence of drugs, raise drug tests to worldwide interest. We developed a one-step extraction technique for cocaine in saliva and analyzed reference samples with laser spectroscopy employing two different schemes. The first is based on attenuated total reflection (ATR), which is applied to dried samples. The second scheme uses transmission measurements for the analysis of liquid samples. ATR spectroscopy achieved a limit of detection (LOD) of 3μg/ml. The LOD for the transmission approach in liquid samples is cocaine. An improved stabilization of the set-up should lower the limit of detection significantly.

  15. Protein buffering in model systems and in whole human saliva.

    Directory of Open Access Journals (Sweden)

    Andreas Lamanda

    Full Text Available The aim of this study was to quantify the buffer attributes (value, power, range and optimum of two model systems for whole human resting saliva, the purified proteins from whole human resting saliva and single proteins. Two model systems, the first containing amyloglucosidase and lysozyme, and the second containing amyloglucosidase and alpha-amylase, were shown to provide, in combination with hydrogencarbonate and di-hydrogenphosphate, almost identical buffer attributes as whole human resting saliva. It was further demonstrated that changes in the protein concentration as small as 0.1% may change the buffer value of a buffer solution up to 15 times. Additionally, it was shown that there was a protein concentration change in the same range (0.16% between saliva samples collected at the time periods of 13:00 and others collected at 9:00 am and 17:00. The mode of the protein expression changed between these samples corresponded to the change in basic buffer power and the change of the buffer value at pH 6.7. Finally, SDS Page and Ruthenium II tris (bathophenantroline disulfonate staining unveiled a constant protein expression in all samples except for one 50 kDa protein band. As the change in the expression pattern of that 50 kDa protein band corresponded to the change in basic buffer power and the buffer value at pH 6.7, it was reasonable to conclude that this 50 kDa protein band may contain the protein(s belonging to the protein buffer system of human saliva.

  16. Observations on saliva osmolality during progressive dehydration and partial rehydration.

    Science.gov (United States)

    Taylor, Nigel A S; van den Heuvel, Anne M J; Kerry, Pete; McGhee, Sheena; Peoples, Gregory E; Brown, Marc A; Patterson, Mark J

    2012-09-01

    A need exists to identify dehydrated individuals under stressful settings beyond the laboratory. A predictive index based on changes in saliva osmolality has been proposed, and its efficacy and sensitivity was appraised across mass (water) losses from 1 to 7%. Twelve euhydrated males [serum osmolality: 286.1 mOsm kg(-1) H(2)O (SD 4.3)] completed three exercise- and heat-induced dehydration trials (35.6°C, 56% relative humidity): 7% dehydration (6.15 h), 3% dehydration (with 60% fluid replacement: 2.37 h), repeat 7% dehydration (5.27 h). Expectorated saliva osmolality, measured at baseline and at each 1% mass change, was used to predict instantaneous hydration state relative to mass losses of 3 and 6%. Saliva osmolality increased linearly with dehydration, although its basal osmolality and its rate of change varied among and within subjects across trials. Receiver operating characteristic curves indicated a good predictive power for saliva osmolality when used with two, single-threshold cutoffs to differentiate between hydrated and dehydrated individuals (area under curve: 3% cutoff = 0.868, 6% cutoff = 0.831). However, when analysed using a double-threshold detection technique (3 and 6%), as might be used in a field-based monitor, <50% of the osmolality data could correctly identify individuals who exceeded 3% dehydration. Indeed, within the 3-6% dehydration range, its sensitivity was 64%, while beyond 6% dehydration, this fell to 42%. Therefore, while expectorated saliva osmolality tracked mass losses within individuals, its large intra- and inter-individual variability limited its predictive power and sensitivity, rendering its utility questionable within a universal dehydration monitor.

  17. Quantitative determination of caffeine and alcohol in energy drinks and the potential to produce positive transdermal alcohol concentrations in human subjects.

    Science.gov (United States)

    Ayala, Jessica; Simons, Kelsie; Kerrigan, Sarah

    2009-01-01

    The purpose of this study was to determine whether non-alcoholic energy drinks could result in positive "alcohol alerts" based on transdermal alcohol concentration (TAC) using a commercially available electrochemical monitoring device. Eleven energy drinks were quantitatively assayed for both ethanol and caffeine. Ethanol concentrations for all of the non-alcoholic energy drinks ranged in concentration from 0.03 to 0.230% (w/v) and caffeine content per 8-oz serving ranged from 65 to 126 mg. A total of 15 human subjects participated in the study. Subjects consumed between 6 and 8 energy drinks over an 8-h period. The SCRAM II monitoring device was used to determine TACs every 30 min before, during, and after the study. None of the subjects produced TAC readings that resulted in positive "alcohol alerts". TAC measurements for all subjects before, during and after the energy drink study period (16 h total) were study consumed a quantity of non-alcoholic energy drink that greatly exceeds what would be considered typical. Based on these results, it appears that energy drink consumption is an unlikely explanation for elevated TACs that might be identified as potential drinking episodes or "alcohol alerts" using this device.

  18. Round robin performance testing of organic photovoltaic devices

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Zubillaga, Oihana; de Seoane, José María Vega

    2014-01-01

    This study addresses the issue of poor intercomparability of measurements of organic photovoltaic (OPV) devices among different laboratories. We present a round robin performance testing of novel OPV devices among 16 laboratories, organized within the framework of European Research Infrastructure...

  19. Medical Devices; Clinical Chemistry and Clinical Toxicology Devices; Classification of the Organophosphate Test System. Final order.

    Science.gov (United States)

    2017-10-18

    The Food and Drug Administration (FDA or we) is classifying the organophosphate test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the organophosphate test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  20. Medical Devices; Hematology and Pathology Devices; Classification of a Cervical Intraepithelial Neoplasia Test System. Final order.

    Science.gov (United States)

    2018-01-03

    The Food and Drug Administration (FDA or we) is classifying the cervical intraepithelial neoplasia (CIN) test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the CIN test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  1. Metronidazole as a radiosensitizer: a preliminary report on estimation in serum and saliva

    International Nuclear Information System (INIS)

    Karim, A.B.M.F.; Faber, D.B.; Haas, R.E.; Hoekstra, F.H.; Njo, K.H.

    1980-01-01

    Some studies indicate the clinical benefit of hypoxic radiosensitizers in patients who are undergoing radiotherapy. Serum level of sensitizers are usualy advised; however they are very demanding on the patient. Saliva level of the sensitizers may be an alternative method. This study correlated serum level of metronidazole to the saliva level in 10 patients who were undergoing radiotherapy with the sensitizer. A change to the saliva level method appears to relieve the patients

  2. La saliva como medio de diagnóstico de VIH

    Directory of Open Access Journals (Sweden)

    Ricardo Medina Madrid

    2000-12-01

    Full Text Available La saliva como medio diagnóstico permite reconocer las concentraciones de una serie de componentes tanto endógenos como exógenos presentes en el organismo. Gracias a los anticuerpos presentes en la saliva se pueden aplicar las nuevas tecnologías biomédicas en el diagnóstico del síndrome de inmunodeficiencia humana causado por el VIH. Este novedoso método posee numerosas ventajas con respecto a las pruebas en sangre. Se plantea información sobre los fluidos bucales, los diversos componentes con posibilidad de diagnóstico presentes en la saliva y se establecen las características de un método diagnóstico (Omni-Sal® aplicado a personas que padecen de alguna enfermedad del complejo bucal. Descriptores

  3. [Activity of alpha-amylase and concentration of protein in saliva of pregnant women].

    Science.gov (United States)

    Ciejak, Magdalena; Olszewska, Maria; Jakubowska, Katarzyna; Zebiełowicz, Dariusz; Safranow, Krzysztof; Chlubek, Dariusz

    2007-01-01

    One of the hypothetical reasons of the increased incidence of caries in women during the pregnancy may be the increased activity of alpha-amylase, which can be found in their saliva. The enzyme takes part in the process of decomposition of simple sugars, which make basic substrate for caries-causing bacteria. The aim of the paper was the evaluation of the influence of pregnancy and gestational age on the activity of alpha-amylase and the concentration of protein in women's saliva. The examined group consisted of 64 pregnant women at age 17-39, between 21st and 40th week of pregnancy. The control group consisted of 44 healthy women at age 20-35, who were not pregnant. In saliva, which was taken before morning meal, without stimulation, protein concentration was determined by Bradford method and the activity of amylase was determined by kinetic method. The activity of amylase correlated strongly and positively with protein concentration in saliva of both the pregnant (RS = +0.65; p women. There were no significant differences between examined parameters in the examined and the control group. It has been observed in the examined group, that there is the significant negative correlation between protein concentration in saliva and the week of pregnancy (RS = -0.35; p increased caries incidence of pregnant women. However, the observed changes of total protein concentration in saliva during pregnancy, suggest that the exact cognition of proteins in pregnant women's saliva may reveal new mechanisms, which lead to an increase of caries risk.

  4. 14 CFR 120.11 - Refusal to submit to a drug or alcohol test by a Part 61 certificate holder.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Refusal to submit to a drug or alcohol test...: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Individuals Certificated Under Parts 61, 63, and 65 § 120.11 Refusal to submit to a drug or alcohol test by a Part 61 certificate holder. (a) This...

  5. 14 CFR 120.15 - Refusal to submit to a drug or alcohol test by a Part 65 certificate holder.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Refusal to submit to a drug or alcohol test...: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Individuals Certificated Under Parts 61, 63, and 65 § 120.15 Refusal to submit to a drug or alcohol test by a Part 65 certificate holder. (a) This...

  6. 14 CFR 120.13 - Refusal to submit to a drug or alcohol test by a Part 63 certificate holder.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Refusal to submit to a drug or alcohol test...: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Individuals Certificated Under Parts 61, 63, and 65 § 120.13 Refusal to submit to a drug or alcohol test by a Part 63 certificate holder. (a) This...

  7. Testing device for control rod drives

    International Nuclear Information System (INIS)

    Hayakawa, Toshifumi.

    1992-01-01

    A testing device for control rod drives comprises a logic measuring means for measuring an output signal from a control rod drive logic generation circuit, a control means for judging the operation state of a control rod and a man machine interface means for outputting the result of the judgement. A driving instruction outputted from the control rod operation device is always monitored by the control means, and if the operation instruction is stopped, a testing signal is outputted to the control rod control device to simulate a control rod operation. In this case, the output signal of the control rod drive logic generation circuit is held in a control rod drive memory means and intaken into a logic analysis means for measurement and an abnormality is judged by the control means. The stopping of the control rod drive instruction is monitored and the operation abnormality of the control rod is judged, to mitigate the burden of an operator. Further, the operation of the control rod drive logic generation circuit can be confirmed even during a nuclear plant operation by holding the control rod drive instruction thereby enabling to improve maintenance efficiency. (N.H.)

  8. Optical tests for using smartphones inside medical devices

    Science.gov (United States)

    Bernat, Amir S.; Acobas, Jennifer K.; Phang, Ye Shang; Hassan, David; Bolton, Frank J.; Levitz, David

    2018-02-01

    Smartphones are currently used in many medical applications and are more frequently being integrated into medical imaging devices. The regulatory requirements in existence today however, particularly the standardization of smartphone imaging through validation and verification testing, only partially cover imaging characteristics with a smartphone. Specifically, it has been shown that smartphone camera specifications are of sufficient quality for medical imaging, and there are devices which comply with the FDA's regulatory requirements for a medical device such as a device's field of view, direction of viewing and optical resolution and optical distortion. However, these regulatory requirements do not call specifically for color testing. Images of the same object using automatic settings or different light sources can show different color composition. Experimental results showing such differences are presented. Under some circumstances, such differences in color composition could potentially lead to incorrect diagnoses. It is therefore critical to control the smartphone camera and illumination parameters properly. This paper examines different smartphone camera settings that affect image quality and color composition. To test and select the correct settings, a test methodology is proposed. It aims at evaluating and testing image color correctness and white balance settings for mobile phones and LED light sources. Emphasis is placed on color consistency and deviation from gray values, specifically by evaluating the ΔC values based on the CIEL*a*b* color space. Results show that such standardization minimizes differences in color composition and thus could reduce the risk of a wrong diagnosis.

  9. The Alcohol Use Disorders Identification Test (AUDIT: reliability and validity of the Greek version

    Directory of Open Access Journals (Sweden)

    Bratis Dimitris

    2009-05-01

    Full Text Available Abstract Background Problems associated with alcohol abuse are recognised by the World Health Organization as a major health issue, which according to most recent estimations is responsible for 1.4% of the total world burden of morbidity and has been proven to increase mortality risk by 50%. Because of the size and severity of the problem, early detection is very important. This requires easy to use and specific tools. One of these is the Alcohol Use Disorders Identification Test (AUDIT. Aim This study aims to standardise the questionnaire in a Greek population. Methods AUDIT was translated and back-translated from its original language by two English-speaking psychiatrists. The tool contains 10 questions. A score ≥ 11 is an indication of serious abuse/dependence. In the study, 218 subjects took part: 128 were males and 90 females. The average age was 40.71 years (± 11.34. From the 218 individuals, 109 (75 male, 34 female fulfilled the criteria for alcohol dependence according to the Diagnostic and Statistical Manual of Mental Disorders, 4th edition (DSM-IV, and presented requesting admission; 109 subjects (53 male, 56 female were healthy controls. Results Internal reliability (Cronbach α was 0.80 for the controls and 0.80 for the alcohol-dependent individuals. Controls had significantly lower average scores (t test P 8 was 0.98 and its specificity was 0.94 for the same score. For the alcohol-dependent sample 3% scored as false negatives and from the control group 1.8% scored false positives. In the alcohol-dependent sample there was no difference between males and females in their average scores (t test P > 0.05. Conclusion The Greek version of AUDIT has increased internal reliability and validity. It detects 97% of the alcohol-dependent individuals and has a high sensitivity and specificity. AUDIT is easy to use, quick and reliable and can be very useful in detection alcohol problems in sensitive populations.

  10. The Alcohol Use Disorders Identification Test (AUDIT): reliability and validity of the Greek version.

    Science.gov (United States)

    Moussas, George; Dadouti, Georgia; Douzenis, Athanassios; Poulis, Evangelos; Tzelembis, Athanassios; Bratis, Dimitris; Christodoulou, Christos; Lykouras, Lefteris

    2009-05-14

    Problems associated with alcohol abuse are recognised by the World Health Organization as a major health issue, which according to most recent estimations is responsible for 1.4% of the total world burden of morbidity and has been proven to increase mortality risk by 50%. Because of the size and severity of the problem, early detection is very important. This requires easy to use and specific tools. One of these is the Alcohol Use Disorders Identification Test (AUDIT). This study aims to standardise the questionnaire in a Greek population. AUDIT was translated and back-translated from its original language by two English-speaking psychiatrists. The tool contains 10 questions. A score >or= 11 is an indication of serious abuse/dependence. In the study, 218 subjects took part: 128 were males and 90 females. The average age was 40.71 years (+/- 11.34). From the 218 individuals, 109 (75 male, 34 female) fulfilled the criteria for alcohol dependence according to the Diagnostic and Statistical Manual of Mental Disorders, 4th edition (DSM-IV), and presented requesting admission; 109 subjects (53 male, 56 female) were healthy controls. Internal reliability (Cronbach alpha) was 0.80 for the controls and 0.80 for the alcohol-dependent individuals. Controls had significantly lower average scores (t test P 8 was 0.98 and its specificity was 0.94 for the same score. For the alcohol-dependent sample 3% scored as false negatives and from the control group 1.8% scored false positives. In the alcohol-dependent sample there was no difference between males and females in their average scores (t test P > 0.05). The Greek version of AUDIT has increased internal reliability and validity. It detects 97% of the alcohol-dependent individuals and has a high sensitivity and specificity. AUDIT is easy to use, quick and reliable and can be very useful in detection alcohol problems in sensitive populations.

  11. Erosive effect of energy drinks alone and mixed with alcohol on human enamel surface.An in vitro study.

    Directory of Open Access Journals (Sweden)

    Katherine Beltrán

    2017-01-01

    Full Text Available Objective: To assess the erosive effect of energy drinks (ED alone and mixed with alcohol on the human enamel surface in vitro. Methods: Twenty non-erupted human third molars were vertically sectioned in half. Specimens were exposed to 5mL of ED plus 5mL of artificial saliva or 5mL of ED plus 5mL of artificial saliva plus 5mL of alcohol (Pisco. Exposure times were set at 30min and 60min. Erosive assessments were made using scanning electron microscopy (SEM and energy-dispersive x-ray spectroscopy (EDS. The ED analyzed were Mr. Big, Kem Extreme, Red Bull, and Monster Energy. ED pH measurements were performed at 25°C and titration was done with NaOH 0.1mol/L. Results: The pH ranges were: ED alone 2.55 to 3.46, ED mixed with artificial saliva 2.60 to 3.55, ED mixed with Pisco 2.82 to 3.70, and ED mixed with both 2.92 to 3.86. The pH of Pisco was 6.13, and Pisco mixed with artificial saliva had a pH of 6.23. Titration showed a pH range from 3.5 to 5.7. SEM-EDS analysis showed that Mr. Big and Monster led to clear demineralization at 30 min and remineralization at 60m in. Pisco slightly decreased the erosive effect of these ED. Kem Xtreme and Red Bull led to no demineralization in the first hour. Conclusion: According to the pH, acidity and EDS analysis, the ED of the present study likely caused enamel erosion in human teeth surface dependent on exposure time.

  12. The Effects of Mothers' Protective Parenting and Alcohol Use on Emerging Adults' Alcohol Use: Testing Indirect Effects Through Prototype Favorability Among African American Youth.

    Science.gov (United States)

    Cleveland, Michael J; Turrisi, Rob; Gibbons, Frederick X; Gerrard, Meg; Marzell, Miesha

    2018-06-07

    We examined how mothers' protective parenting and alcohol use influenced changes in offspring's heavy drinking among a sample of African American youth. The conceptual model also tested indirect effects of mothers' behaviors, through changes in the youths' social images (i.e., prototypes) of heavy drinkers, derived from the prototype willingness (PW) model. Participants were 686 emerging adults (55% female) from the Family and Community Health Study (FACHS), an ongoing prospective study of African American families. Three waves of FACHS data were used as follows: T3 during 10th grade (M age = 16.3 years), T4 shortly after high school (M age = 19.4 years), and T5 3 years later (M age = 22.1 years). Mothers' self-reports of protective parenting and alcohol use were assessed at T4. Two separate path models tested the study hypotheses. The first model specified direct and indirect effects of mothers' protective parenting and alcohol use. The second model added interaction terms between the protective parenting behaviors and mothers' alcohol use. The analyses were first conducted using the full sample and then repeated separately for female and male participants. Maternal alcohol use had a positive and direct effect on offspring's alcohol use. Mothers' endorsement of alcohol-related rules inhibited normative increases in the favorability of the offspring's social image of heavy drinkers (prototype) while her warmth was positively related to these increases. Maternal alcohol use amplified the positive association between mothers' warmth and the daughters' increased drinking. For sons, maternal alcohol use increased the positive association between alcohol-related rules and increased prototype favorability. Results indicated clear gender differences in how mothers' behaviors influence her offspring's alcohol use during the transition to emerging adulthood. Interventions that target culturally specific risk and protective factors within the family environment are

  13. Estimating BrAC from transdermal alcohol concentration data using the BrAC estimator software program.

    Science.gov (United States)

    Luczak, Susan E; Rosen, I Gary

    2014-08-01

    Transdermal alcohol sensor (TAS) devices have the potential to allow researchers and clinicians to unobtrusively collect naturalistic drinking data for weeks at a time, but the transdermal alcohol concentration (TAC) data these devices produce do not consistently correspond with breath alcohol concentration (BrAC) data. We present and test the BrAC Estimator software, a program designed to produce individualized estimates of BrAC from TAC data by fitting mathematical models to a specific person wearing a specific TAS device. Two TAS devices were worn simultaneously by 1 participant for 18 days. The trial began with a laboratory alcohol session to calibrate the model and was followed by a field trial with 10 drinking episodes. Model parameter estimates and fit indices were compared across drinking episodes to examine the calibration phase of the software. Software-generated estimates of peak BrAC, time of peak BrAC, and area under the BrAC curve were compared with breath analyzer data to examine the estimation phase of the software. In this single-subject design with breath analyzer peak BrAC scores ranging from 0.013 to 0.057, the software created consistent models for the 2 TAS devices, despite differences in raw TAC data, and was able to compensate for the attenuation of peak BrAC and latency of the time of peak BrAC that are typically observed in TAC data. This software program represents an important initial step for making it possible for non mathematician researchers and clinicians to obtain estimates of BrAC from TAC data in naturalistic drinking environments. Future research with more participants and greater variation in alcohol consumption levels and patterns, as well as examination of gain scheduling calibration procedures and nonlinear models of diffusion, will help to determine how precise these software models can become. Copyright © 2014 by the Research Society on Alcoholism.

  14. In vitro assessment of the antimicrobial effects of pomegranate (Punica granatum L. peel decoction on saliva samples

    Directory of Open Access Journals (Sweden)

    Solon José de Oliveira Leite

    2014-01-01

    Full Text Available Several products have been developed to eliminate or reduce potential pathogenic microorganisms of the oral microbiome. The continuous use of these synthetic products can result in side effects such as vomiting, diarrhea, darkening of the teeth and the induction of microbial resistance. Pomegranate (Punica granatum peel decoction was tested to assess its antimicrobial activity. In vitro analysis showed the decoction had antimicrobial activity against strains of Pseudomonas aeruginosa and Candida albicans, but none was detected against Enterococcus faecalis. When tested on saliva samples from children, the decoction showed great potential in reducing the load of microorganisms, the inhibition haloes produced with saliva samples being similar to those of the antimicrobial control (0.12% chlorhexidine. The pomegranate peel decoction in water could thus provide a promising source for developing solutions for use against oral diseases.

  15. Tongue-mandible coupling movements during saliva swallowing.

    Science.gov (United States)

    Bourdiol, P; Mishellany-Dutour, A; Peyron, M-A; Woda, A

    2014-03-01

    The purpose of this study was to measure the tongue and mandible positions and displacements in relation to the maxilla in the midsagittal plane to characterize the different saliva swallowing patterns by recording their kinematics. A 2D electromagnetic articulograph using four transducer coils, three attached to the upper surface of the tongue midline plus one attached to the chin anterior part allowed continuous evaluation of tongue and chin movements in twelve young adults in good general health. During 170 s sequences recorded at a frequency of 100 Hz, subjects were at rest, silently reading a text they had chosen. The subjects were free to swallow during the sequence. Deglutition of accumulated saliva was analysed after averaging all values obtained during successive 250 ms periods. We identified three elementary swallowing patterns. Mean duration of tongue-mandible movements were 1·51 ± 0·17 s, 1·63 ± 0·14 s and 2·00 ± 0·08 s for the first, second and third patterns respectively. In the light of other studies based on intra-oral pressure recordings, our results help to understand the tongue-mandible coupling behaviours involved in managing an in-mouth saliva bolus during the three elementary swallowing patterns identified. © 2014 John Wiley & Sons Ltd.

  16. Glucocorticoid exposure in preterm babies predicts saliva cortisol response to immunization at 4 months.

    Science.gov (United States)

    Glover, Vivette; Miles, Rachel; Matta, Simon; Modi, Neena; Stevenson, James

    2005-12-01

    Preterm babies are exposed to multiple stressors and this may have long-term effects. In particular, high levels of endogenous cortisol might have a programming effect on the hypothalamic-pituitary-adrenal axis as may administered glucocorticoids. In this study, we aimed to test the hypothesis that the level of endogenous and exogenous glucocorticoid exposure during the neonatal period predicts the saliva cortisol response to immunization at 4 mo of age. We followed 45 babies born below 32 wk gestation. We showed that their concentration of plasma cortisol during the first 4 wk was 358, 314, 231, and 195 nmol/L cortisol, respectively (geometric mean). This is four to seven times higher than fetal levels at the same gestational age range. We used routine immunization at 4 mo and 12 mo as a stressor and measured the change in saliva cortisol as the stress response. Mean circulating cortisol in the first 4 wk predicted the cortisol response at 4 but not at 12 mo. Path analysis showed that birthweight for gestational age, therapeutic antenatal steroids, and therapeutic postnatal steroids also contributed to the magnitude of the saliva cortisol response at 4 mo. This provides evidence that the magnitude of glucocorticoid exposure, both endogenous and exogenous, may have an effect on later stress responses.

  17. Psychometric properties of the Chinese version of the Michigan Alcoholism Screening Test (MAST-C) for patients with alcoholism.

    Science.gov (United States)

    Hsueh, Yu-Jung; Chu, Hsin; Huang, Chang-Chih; Ou, Keng-Liang; Chen, Chiung-Hua; Chou, Kuei-Ru

    2014-04-01

    The aim of this study was to examine the psychometric properties of the Chinese version of the Michigan Alcoholism Screening Test (MAST-C). The sensitivity, specificity, and positive and negative predictive values for the MAST-C were examined in this study. The MAST-C had an internal consistency of 0.83 and a test-retest reliability of 0.89. It had a good content validity index of 0.92. Factor analysis identified four factors and the optimal cutoff point for the MAST-C was a score of 6/7, which yielded a sensitivity of 0.92, a specificity of 0.83, a positive predictive value of 0.92, and a negative predictive value of 0.83. The MAST-C provides a fast, accurate, and sensitive method for clinically diagnosing alcoholism and clinical management. © 2013 Wiley Periodicals, Inc.

  18. [History of studies of alcohol toxicology].

    Science.gov (United States)

    Konopka, Tomasz

    2010-01-01

    The early history of forensic alcohology was presented, based on writings from the beginning of the 20th century and numerous forensic medical protocols from autopsies performed in Institute of Forensic Medicine in Cracow in the 19th and 20th century. Ethanol has not been considered a poison for a long time. Suspicion of its toxic effect resulted from cases of deaths as a results of people betting who can drink more alcohol. In case of alcohol poisoning, autopsy does not show any typical changes, so the poisonings have not been recognized for many years. At the beginning of the 20th century, the first chemical tests appeared. They were able to detect the presence of alcohol in tissues. A method for measuring the amount of alcohol in blood was also developed. The majority of methods were based on distillation of blood and inspection of the resultant distillate by physical methods (interferometry, colorimetry, refractometry, gravimetry, measuring thermal expansion and electrical conduction) or chemical methods using different reactions (oxidation of alcohol to acetic acid, reducing potassium dichromate by alcohol, alkylation of iodine by alcohol) and marking the amount of products of reaction by titration. Distillation of blood samples required complicated chemical devices and was very time consuming. Erik Widmark suggested a certain method in 1920, in which distillation of a blood sample took place in the same container, in which titration was performed earlier--the so-called Widmark's Flask. It allowed for distilling many samples in an incubator at the same time and dramatically shortened the time of research. Widmark's method was applied to testing drivers and people who committed crimes and was used in the whole world for many following years.

  19. Radioimmunological analysis of circadian rhythms of cortisol and melatonin in saliva

    International Nuclear Information System (INIS)

    Demel, A.W.

    1990-12-01

    Since blood cortisol (F) and melatonin (MTL) display a circadian secretion pattern and since the saliva concentration of these hormones is an excellent indicator of its blood levels the measurement of salivary F and MLT may be used for examining circadian rhythmicity. In these study the relationship between salivary F and MLT was explored. For this purpose it was necessary first to establish and validate a radioimmunoassay for F in saliva: salivary F was determined by a direct radioimmunoassay using cortisol-3-(O-carboxymethyl) oximino-(2- ( 125 I)iodohistamin) as tracer and cortisol-3-CMO-BSA antiserum. The parallel measurement of F levels in saliva and serum of adults gave an excellent correlation (r=0.87, p 0.00956x ). Serum F was assayed on the Abott TDX-System using a radioimmunofluorescence method. Secondly, using this assay the circadian saliva F pattern was determined as well as the pattern of salivary MLT in 9 young, healthy volunteers. For saliva MLT estimations a previously published method was applied (SCHULZ et al 1990). Using a computerized program (RHYTHM) written by EVE v. CAUTER (1979), the hormone data of each individuum were examined for circadian rhythmicity and its acrophases (time of occurrence of the maximum of a sinusoid fitted to the data). The F acrophase occured between 7:00 and 12:00 h (Mean: 8:06 h, SD: 93.8 min). The acrophase for MLT was found between 0:00 and 6:00 h (Mean: 3:33 h, SD: 104.4 min). There was a phase difference between both hormones of 3 to 7 hours (Mean: 292.5 min, SD: 74.7 min). The easy stress-free non-invasive nature of saliva collection makes saliva to one of the most accessible body fluids and of high value in studying the circadian system in healthy humans as well as in infants, children, pregnant women and anaemic patients. Measurements of salivary F and MLT may help to elucidate not only the circadian rhythms of these hormones under normal and pathological conditions but it may also provide insight in

  20. Software test attacks to break mobile and embedded devices

    CERN Document Server

    Hagar, Jon Duncan

    2013-01-01

    Address Errors before Users Find Them Using a mix-and-match approach, Software Test Attacks to Break Mobile and Embedded Devices presents an attack basis for testing mobile and embedded systems. Designed for testers working in the ever-expanding world of ""smart"" devices driven by software, the book focuses on attack-based testing that can be used by individuals and teams. The numerous test attacks show you when a software product does not work (i.e., has bugs) and provide you with information about the software product under test. The book guides you step by step starting with the basics. It

  1. Continuous analysis of parotid saliva during resting and short-duration simulated chewing

    NARCIS (Netherlands)

    Neyraud, E.; Bult, J.H.F.; Dransfield, E.

    2009-01-01

    Objective: Parotid saliva flow is increased by mastication and its composition is also modified. The aim of this work was to clarify the relationships between flow rate, pH and protein concentration, during resting and short-duration simulated chewing, using continuous and fractional saliva

  2. Leaching of 210Po in human saliva from smokeless tobacco

    International Nuclear Information System (INIS)

    Syed, U.F.; Bari, A.; Husain, L.; Husain, L.

    2009-01-01

    Use of smokeless tobacco (SLT) is associated with cancer of the oral cavity. 210 Po, a known carcinogen present in SLT may leach into the saliva when the snuff is held in the mouth. Alpha emission from leached 210 Po can cause oral tissue damage, especially in the presence of non healing ulcers seen frequently in snuff users' mouth. Leaching of 210 Po from SLT in human saliva was determined for six popular US snuff brands. 210 Po was leached into human saliva for 30 min, separated radiochemically and its activity was determined by α-counting. Approximately 2-10% of 210 Po present in SLT was observed to leach. Annual exposure from leached 210 Po, based on average daily consumption of 15 g of SLT, was calculated to range from 1.1 to 3.8 Bq year -1 . (author)

  3. Trefoil factors in saliva and gingival tissues of patients with chronic periodontitis

    DEFF Research Database (Denmark)

    Chaiyarit, Ponlatham; Chayasadom, Anek; Wara-Aswapati, Nawarat

    2012-01-01

    BACKGROUND: Trefoil factors (TFFs) are secreted molecules that are involved in cytoprotection against tissue damage and the immune response. TFFs have been detected in saliva and oral tissues, but their clinical significance has never been investigated in patients with chronic periodontitis....... The objective of this study is to determine whether TFF expression in saliva and gingival tissues is associated with periodontal pathology. METHODS: Saliva and gingival tissue samples were collected from 25 non-periodontitis individuals and 25 patients with chronic periodontitis (CP). Enzyme...... observed in patients with CP (P = 0.003 and P periodontal pathology and number of Porphyromonas gingivalis...

  4. Pressure-Application Device for Testing Pressure Sensors

    Science.gov (United States)

    2002-01-01

    A portable pressure-application device has been designed and built for use in testing and calibrating piezoelectric pressure transducers in the field. The device generates pressure pulses of known amplitude. A pressure pulse (in contradistinction to a steady pressure) is needed because in the presence of a steady pressure, the electrical output of a piezoelectric pressure transducer decays rapidly with time. The device includes a stainless- steel compressed-air-storage cylinder of 500 cu cm volume. A manual hand pump with check valves and a pressure gauge are located at one end of the cylinder. A three-way solenoid valve that controls the release of pressurized air is located at the other end of the cylinder. Power for the device is provided by a 3.7-V cordless-telephone battery. The valve is controlled by means of a pushbutton switch, which activates a 5 V to +/-15 V DC-to-DC converter that powers the solenoid. The outlet of the solenoid valve is connected to the pressure transducer to be tested. Before the solenoid is energized, the transducer to be tested is at atmospheric pressure. When the solenoid is actuated by the push button, pressurized air from inside the cylinder is applied to the transducer. Once the pushbutton is released, the cylinder pressure is removed from the transducer and the pressurized air applied to the transducer is vented, bringing the transducer back to atmospheric pressure. Before this device was used for actual calibration, its accuracy was checked with a NIST (National Institute of Standards and Technology) traceable calibrator and commercially calibrated pressure transducers. This work was done by Wanda Solano of Stennis Space Center and Greg Richardson of Lockheed Martin Corp.

  5. Abrasion Testing of Critical Components of Hydrokinetic Devices

    Energy Technology Data Exchange (ETDEWEB)

    Worthington, Monty [ORPC Alaska; Ali, Muhammad [Ohio University; Ravens, Tom [University of Alaska Anchorage

    2013-12-06

    The objective of the Abrasion Testing of Critical Components of Hydrokinetic Devices (Project) was to test critical components of hydrokinetic devices in waters with high levels of suspended sediment – information that is widely applicable to the hydrokinetic industry. Tidal and river sites in Alaska typically have high suspended sediment concentrations. High suspended sediment also occurs in major rivers and estuaries throughout the world and throughout high latitude locations where glacial inputs introduce silt into water bodies. In assessing the vulnerability of technology components to sediment induced abrasion, one of the greatest concerns is the impact that the sediment may have on device components such as bearings and seals, failures of which could lead to both efficiency loss and catastrophic system failures.

  6. Anthropometric comparison of Anthropometric Test Device (ATD ...

    African Journals Online (AJOL)

    Anthropometric test device (ATD) is surrogate used in automotive crash testing. Female ATDs used worldwide in the evaluation of vehicle safety performance was produced based on anthropometry of U.S. population. This work is aimed at assessing the difference between the anthropometric dimensions of Nigerian female ...

  7. 75 FR 8526 - Procedures for Transportation Workplace Drug and Alcohol Testing Programs

    Science.gov (United States)

    2010-02-25

    ... 2105-AD64 Procedures for Transportation Workplace Drug and Alcohol Testing Programs AGENCY: Office of... required method. However, in response to comments requesting additional flexibility in testing methods, the... may increase flexibility and lower costs for employers who choose to use them over more expensive...

  8. Measurement of iron, magnesium and chromium concentrations in the saliva of the patients undergoing fixed orthodontic treatment

    Directory of Open Access Journals (Sweden)

    Valiollah Arash

    2012-09-01

    Full Text Available Introduction: Stainless steel alloy used in orthodontics has elements such as iron - magnesium and chromium , which may be released due to corrosion in the mouth . The aim of this study was to evaluate the changes of these elements in the saliva of patients undergoing fixed orthodontic treatment. Methods: In a clinical study with simple non- random sampling , 1ml saliva of 11 patients (7 females and 4 males who needed fixed orthodontic treatment and had no restorations or crowns were collected. During the fixed orthodontic treatment at successive times ( a day, a week, a month , two months and six months , 1 ml of saliva was collected and evaluated for the amount of iron ( spectrophotometry, chromium ( atomic absorption, and magnesium ( spectrophotometry . Bracket , band and wire used in all patients were stainless steel alloy and were manufactured by Dentaurum Company. After sample collection , the data analysis was performed with " Azeri- 5" and "10SPSS" software and repeated measures test. Results: The mean concentration of iron 66.326±0.541, chromium 0.483±0.324 and magnesium 0.552±293 decreased during the study but these results were not statistical y significant (p>0.05. Conclusions: Iron , chromium and magnesium concentration do not exceed the standard limits in saliva during orthodontic treatment.

  9. Effect of Saliva on Load-Deflection Characteristics of Superelastic Nickel-Titanium Orthodontic Wires

    OpenAIRE

    Hosseinzadeh Nik, T.; Ghadirian, H.; Ahmadabadi, M. Nili; Shahhoseini, T.; Haj-Fathalian, M.

    2012-01-01

    Statement of Problem: Most published results about the features of NiTi wires are based on the mechanical laboratory tests in a dry environment.Purpose of Study: The purpose of this study was to investigate the effect of saliva on load-deflection characteristics of superelastic NiTi wires.Materials and Methods: In this experimental study, 15 wires of three kinds of NiTi wires (Sentalloy, Force I and Truflex) were prepared; five of them were tested in their as-received condition to provide bas...

  10. Salivary flow rate and biochemical composition analysis in stimulated whole saliva of children with cystic fibrosis.

    Science.gov (United States)

    da Silva Modesto, Karine Barros; de Godói Simões, Jéssica Bueno; de Souza, Amanda Ferreira; Damaceno, Neiva; Duarte, Danilo Antonio; Leite, Mariana Ferreira; de Almeida, Eliete Rodrigues

    2015-11-01

    It is recognized that cystic fibrosis (CF) patients present a risk for oral diseases, since it affects exocrine glands, and the treatment consists of a carbohydrate-rich diet. Recognizing the protective function of saliva on maintaining oral health, the aim of the study was to evaluate salivary parameters in stimulated whole saliva from children with CF. A case-control study was conducted comparing stimulated whole saliva of healthy (n=28; control group) and CF children (n=21; experimental group). Salivary flow rate, initial pH, buffer capacity (total and in each range of pH), total protein and sialic acid (total, free, and conjugated) concentration, α-amylase and salivary peroxidase activities were evaluated. Data were compared by two-tailed Student t test (95% CI; p ≤ 0.05). CF patients presented a significant reduction in salivary parameters compared with the control group (p ≤ 0.05): salivary flow rate (36%), buffer capacity (pH range from 6.9 to 6.0), sialic acid concentration (total 75%, free 61%, and conjugated 83%); α-amylase and salivary peroxidase activities (55%). Additionally, a significant increase in total protein concentration (180%) of stimulated whole saliva from CF patients was verified compared with the control group (p ≤ 0.05). Children with CF presented significant changes in salivary composition, including salivary flow rate, buffering capacity and protective proteins of the oral cavity, compared with children without CF. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Whole Saliva has a Dual Role on the Adherence of Candida albicans to Polymethylmetacrylate.

    Science.gov (United States)

    Elguezabal, N; Maza, J L; Dorronsoro, S; Pontón, J

    2008-01-01

    Adhesion of Candida albicans to acrylic of dental prostheses or to salivary macromolecules adsorbed on their surface is believed to be a critical event in the development of denture stomatitis. In previous studies our group has shown that adhesion of C. albicans germ tubes to polystyrene is decreased by saliva whereas C. albicans yeast cells adhesion to the same material is enhanced. The results presented in this study confirm this dual role played by whole saliva, since it decreased the adhesion of germ tubes but increased the adhesion of yeast cells to polymethylmetacrylate (PMMA). These effects mediated by whole saliva do not seem to be related to an inhibition of the germination of C. albicans, since similar levels of filamentation were observed in presence and absence of saliva. These results may give new insights into the conflicting role of saliva in the adhesion of C. albicans to acrylic resins of dental prostheses.

  12. A Review on Key Issues and Challenges in Devices Level MEMS Testing

    Directory of Open Access Journals (Sweden)

    Muhammad Shoaib

    2016-01-01

    Full Text Available The present review provides information relevant to issues and challenges in MEMS testing techniques that are implemented to analyze the microelectromechanical systems (MEMS behavior for specific application and operating conditions. MEMS devices are more complex and extremely diverse due to the immersion of multidomains. Their failure modes are distinctive under different circumstances. Therefore, testing of these systems at device level as well as at mass production level, that is, parallel testing, is becoming very challenging as compared to the IC test, because MEMS respond to electrical, physical, chemical, and optical stimuli. Currently, test systems developed for MEMS devices have to be customized due to their nondeterministic behavior and complexity. The accurate measurement of test systems for MEMS is difficult to quantify in the production phase. The complexity of the device to be tested required maturity in the test technique which increases the cost of test development; this practice is directly imposed on the device cost. This factor causes a delay in time-to-market.

  13. 78 FR 26849 - Model Specifications for Breath Alcohol Ignition Interlock Devices (BAIIDs)

    Science.gov (United States)

    2013-05-08

    ... requirements, and asked whether the Model Specifications should limit sensor technology to alcohol-specific sensors (such as fuel cell technology based on electrochemical oxidation of alcohol) or other emerging... have demanded alcohol- specific sensor technology. [Interlocks that] are not alcohol-specific...

  14. Driving under the influence among frequent ecstasy consumers in Australia: trends over time and the role of risk perceptions.

    Science.gov (United States)

    Matthews, Allison Jane; Bruno, Raimondo; Dietze, Paul; Butler, Kerryn; Burns, Lucy

    2014-11-01

    Driving under the influence (DUI) of alcohol and illicit drugs is a serious road safety concern. This research aimed to examine trends in DUI across time and changes in attitudes towards the risks (crash and legal) associated with DUI among regular ecstasy users (REU) interviewed in Australia. Participants were regular (at least monthly) ecstasy users surveyed in 2007 (n=573) or 2011 (n=429) who had driven a car in the last six months. Face to face interviews comprised questions about recent engagement of DUI and roadside breath (alcohol) and saliva (drug) testing. Participants also reported the risk of crash and of being apprehended by police if DUI of alcohol, cannabis, ecstasy, and methamphetamine. There were significant reductions in DUI of psychostimulants (ecstasy, methamphetamine, cocaine, LSD) but not alcohol or cannabis between 2007 and 2011. This was accompanied by increased experience of roadside saliva testing and increases in crash and legal risk perceptions for ecstasy and methamphetamine, but not alcohol or cannabis. When the relationship between DUI and risk variables was examined, low crash risk perceptions were associated with DUI of all substances and low legal risk perceptions were associated with DUI of ecstasy. The observed reduction in DUI of psychostimulants among frequent ecstasy consumers may be related to increased risk awareness stemming from educational campaigns and the introduction of saliva testing on Australian roads. Such countermeasures may be less effective in relation to deterring or changing attitudes towards DUI of cannabis and alcohol among this group. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Performance and Pain Tolerability of Current Diagnostic Allergy Skin Prick Test Devices.

    Science.gov (United States)

    Tversky, Jody R; Chelladurai, Yohalakshmi; McGready, John; Hamilton, Robert G

    2015-01-01

    Allergen skin prick testing remains an essential tool for diagnosing atopic disease and guiding treatment. Sensitivity needs to be defined for newly introduced devices. Our aim was to compare the performance of 10 current allergy skin prick test devices. Single- and multiheaded skin test devices (n = 10) were applied by a single operator in a prospective randomized manner. Histamine (1 and 6 mg/mL) and control diluent were introduced at 6 randomized locations onto the upper and lower arms of healthy subjects. Wheal and flare reactions were measured independently by 2 masked technicians. Twenty-four subjects provided consent, and 768 skin tests were placed. Mean wheal diameter among devices differed from 3.0 mm (ComforTen; Hollister-Stier, Spokane, Wash) to 6.8 mm (UniTest PC; Lincoln Diagnostics, Decatur, Ill) using 1 mg/mL histamine (P Diagnostics, Decatur, Ill; and Sharp-Test; Panatrex, Placentia, Calif) using 6 mg/mL histamine (P pain score of less than 4 on a 10-point visual analog scale. Pain scores were higher among women, but this did not reach statistical significance. The Multi-Test PC and the UniTest PC had the lowest pain scores compared with the other devices. All 10 skin prick test devices displayed good analytical sensitivity and specificity; however, 3 mm cannot arbitrarily be used as a positive threshold. The use of histamine at 1 mg/mL is unacceptable for certain devices but may be preferable for the most sensitive devices. On average, there was no pain score difference between multiheaded and single-head devices. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  16. [Validity of AUDIT test for detection of disorders related with alcohol consumption in women].

    Science.gov (United States)

    Pérula-de Torres, Luis Angel; Fernández-García, José Angel; Arias-Vega, Raquel; Muriel-Palomino, María; Márquez-Rebollo, Encarnación; Ruiz-Moral, Roger

    2005-11-26

    Early detection of patients with alcohol problems is important in clinical practice. The AUDIT (Alcohol Use Disorders Identification Test) questionnaire is a valid tool for this aim, especially in the male population. The objective of this study was to validate how useful is this questionnaire in females patients and to assess their test cut-off point for the diagnosis of alcohol problems in women. 414 woman were recruited in 2 health center and specialized center for addiction treatment. The AUDIT test and a semistructured interview (SCAN as gold standard) were performed to all patients. Internal consistency and criteria validity was assessed. Cronbach alpha was 0.93 (95% confidence interval [CI], 0.921-0.941). When the DSM-IV was taken as reference the most useful cut-off point was 6 points, with 89.6% (95% CI, 76.11-96.02) sensitivity and 95.07% (95% CI, 92.18-96.97) specificity. When CIE-10 was taken as reference the sensitivity was 89.58% (95% CI, 76.56-96.10) and the specificity was 95.33% (95% CI, 92.48-97.17). AUDIT is a questionnaire with good psychometrics properties and is valid for detecting dependence and risk alcohol consumption in women.

  17. Development of a Device for a Material Irradiation Test in the OR Test Hole

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Man Soon; Kang, Y. H.; Kim, B. G.; Choo, K. N.; Sohn, J. M.; Shin, Y. T.; Park, S. J.; Seo, C. K

    2008-05-15

    To develop a technology and a device for the irradiation test for utilization of the OR/IP holes according to the various requirements of users, the properties of the OR/IP holes were investigated and an irradiation device for the OR hole was designed and fabricated. The OR-4, 5 and the IP-9, 10, 11 holes were selected as those suitable to irradiation tests among the test holes located in the out core area. The conceptual design was performed to design a device to irradiate materials using the OR and IP holes. The capsule for the OR holes is fixed by pressing the protection tube using a clamping device, on the other hand the IP capsule is inserted in the hole without a special clamping device. In the basic design of the irradiation device for the OR hole, the capsules having the outside diameter of 50, 52, 54, 56mm were reviewed theoretically to investigate if they meet the hydraulic and vibration conditions required in the HANARO. The results of the pressure drop test showed that the 3 kinds of capsules having diameter of 52, 54, 56mm satisfied the requirement for the pressure difference and flow rate in HANARO. The capsule of {phi}56mm out of the above three satisfied the vibration condition and was finally selected giving consideration of a capacity of specimens. The capsule having a diameter of {phi}56mm was fabricated and the flow rate was measured. Using the velocity data measured at the out-core facility, the heat transfer coefficient, and the temperature on the surface of the capsule was evaluated to confirm it less than the ONB temperature. As a result, the capsule of {phi}56mm was selected for the irradiation test at the OR holes.

  18. The effect of saliva on the fate of nanoparticles.

    Science.gov (United States)

    Teubl, Birgit J; Stojkovic, Biljana; Docter, Dominic; Pritz, Elisabeth; Leitinger, Gerd; Poberaj, Igor; Prassl, Ruth; Stauber, Roland H; Fröhlich, Eleonore; Khinast, Johannes G; Roblegg, Eva

    2018-03-01

    The design of nanocarriers for local drug administration to the lining mucosa requires a sound knowledge of how nanoparticles (NPs) interact with saliva. This contact determines whether NPs agglomerate and become immobile due to size- and interaction-filtering effects or adsorb on the cell surface and are internalized by epithelial cells. The aim of this study was to examine the behavior of NPs in saliva considering physicochemical NP properties. The salivary pore-size distribution was determined, and the viscosity of the fluid inside of the pores was studied with optical tweezers. Distinct functionalized NPs (20 and 200 nm) were dispersed in saliva and salivary buffers and characterized, and surface-bound MUC5B and MUC7 were analyzed by 1D electrophoresis and immunoblotting. NP mobility was recorded, and cellular uptake studies were performed with TR146 cells. The mode diameter of the salivary mesh pores is 0.7 μm with a peak width of 1.9 μm, and pores are filled with a low-viscosity fluid. The physicochemical properties of the NPs affected the colloidal stability and mobility: compared with non-functionalized particles, which did not agglomerate and showed a cellular uptake rate of 2.8%, functionalized particles were immobilized, which was correlated with agglomeration and increased binding to mucins. The present study showed that the salivary microstructure facilitates NP adsorption. However, NP size and surface functionalization determine the colloidal stability and cellular interactions. The sound knowledge of NP interactions with saliva enables the improvement of current treatment strategies for inflammatory oral diseases.

  19. Real-time PCR quantification of six periodontal pathogens in saliva samples from healthy young adults.

    Science.gov (United States)

    Zhou, Xiaodong; Liu, Xiaoli; Li, Jing; Aprecio, Raydolfo M; Zhang, Wu; Li, Yiming

    2015-05-01

    The use of saliva as a diagnostic fluid for the evaluation of periodontal health has gained attention recently. Most published real-time PCR assays focused on quantification of bacteria in subgingival plaque, not in saliva. The aims of this study were to develop a real-time PCR assay for quantification of six periodontal pathogens in saliva and to establish a relationship between the amount of DNA (fg) and colony-forming unit (CFU). TaqMan primers/probe sets were used for the detection of Aggregatibacter actinomycetemcomitans (Aa), Eikenella corrodens (Ec), Fusobacterium nucleatum (Fn), Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi), Tannerella forsythia (Tf), and total bacteria. Six periodontal pathogens and total bacteria in saliva from 24 periodontally healthy individuals were determined. The relationship between the amount of DNA (fg) and CFU was established by measuring the concentrations of extracted bacterial DNA and CFU per milliliter of bacteria on agar plates. Fn, Ec, and Pi were detected in all saliva samples, while 58.5, 45.8, and 33.3% were detected for Tf, Pg, and Aa, respectively. Numbers of Ec and Fn in saliva were highly correlated (R(2) = 0.93, P periodontal pathogens in saliva and estimate the number of live bacteria (CFU). This real-time PCR assay in combination with the relationship between DNA (fg) and CFU has the potential to be an adjunct in evaluation of periodontal health status.

  20. Saliva oxytocin measures do not reflect peripheral plasma concentrations after intranasal oxytocin administration in men.

    Science.gov (United States)

    Quintana, Daniel S; Westlye, Lars T; Smerud, Knut T; Mahmoud, Ramy A; Andreassen, Ole A; Djupesland, Per G

    2018-05-16

    Oxytocin plays an important role in social behavior. Thus, there has been significant research interest for the role of the oxytocin system in several psychiatric disorders, and the potential of intranasal oxytocin administration to treat social dysfunction. Measurement of oxytocin concentrations in saliva are sometimes used to approximate peripheral levels of oxytocin; however, the validity of this approach is unclear. In this study, saliva and plasma oxytocin was assessed after two doses of Exhalation Delivery System delivered intranasal oxytocin (8 IU and 24 IU), intravenous oxytocin (1 IU) and placebo in a double-dummy, within-subjects design with men. We found that intranasal oxytocin (8 IU and 24 IU) administration increased saliva oxytocin concentrations in comparison to saliva oxytocin concentration levels after intravenous and placebo administration. Additionally, we found that saliva oxytocin concentrations were not significantly associated with plasma oxytocin concentrations after either intranasal or intravenous oxytocin administration. Altogether, we suggest that saliva oxytocin concentrations do not accurately index peripheral oxytocin after intranasal or intravenous oxytocin administration, at least in men. The data indicates that elevated oxytocin saliva levels after nasal delivery primarily reflect exogenous administered oxytocin that is cleared from the nasal cavity to the oropharynx, and is therefore a weak surrogate for peripheral blood measurements. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. The Y4-RNA fragment, a potential diagnostic marker, exists in saliva

    Directory of Open Access Journals (Sweden)

    Tatsuya Ishikawa

    2017-06-01

    Full Text Available The 94-nt full-length Y4-RNA is thought to have roles in the initiation of DNA replication and RNA quality control. Although its 31/32-nt fragment also exists abundantly in plasma, little is known about its physiological role. Since the 31/32-nt Y4-RNA fragment in sera is reported to be more abundant in patients with coronary artery disease than healthy persons, the fragment may have a potential for a diagnostic and/or prognostic biomarker for some diseases regardless of its functionality. As a step toward further investigation of its potential utility, we examined if the 31/32-nt Y4-RNA fragment also exists in saliva that can be obtained noninvasively, and showed that, in addition to the 31/32-nt fragment, 14- and 11-nt Y4-RNA fragments are present in all saliva RNA samples from four healthy persons. We established a PCR method to accurately quantitate the amount of the 31/32-nt Y4-RNA fragment, and estimated its amount in saliva of healthy persons to be 0.06 ± 0.04 fmol per nanogram of saliva RNA. We also tried to develop an easier quantitation method using a DNA molecular beacon. Keywords: Y4-RNA fragment, Saliva RNA, Diagnostic/prognostic marker, Next-generation sequencing, RT-PCR, Molecular beacon

  2. Levels of saliva cotinine in electronic cigarette users.

    Science.gov (United States)

    Etter, Jean-François

    2014-05-01

    To assess saliva cotinine levels in experienced users of e-cigarettes ('vapers'). An internet survey in 2011 and 2012, with collection of saliva vials by mail. Participants were 71 users of e-cigarettes enrolled mainly on websites and online forums dedicated to e-cigarettes. Use of e-cigarettes, tobacco and nicotine medications. Collection of saliva by mail and analysis of cotinine by liquid chromatography-mass spectrometry. Most participants (89%) were former smokers, most (92%) were using e-cigarettes daily, had been using e-cigarettes for 12 months on average and puffed a median of 150 times per day on their e-cigarettes [mean = 220 puffs/day, 95% confidence interval (CI) = 169-271]. The median concentration of nicotine in refill liquids was 16 mg/ml (mean = 16.4, 95% CI = 14.5-18.3). In the 62 e-cigarette users who, in the past 5 days, had not used any tobacco or nicotine medications, the median cotinine level was 353 ng/ml (mean = 374, 95% CI = 318-429), the correlation between cotinine and nicotine concentration in e-liquids was r = 0.33 (P = 0.013), and the correlation between cotinine and the number of cigarettes smoked per day before quitting smoking was r = 0.48 (P Addiction.

  3. A novel reflex cough testing device.

    Science.gov (United States)

    Fujiwara, Kazunori; Kawamoto, Katsuyuki; Shimizu, Yoko; Fukuhara, Takahiro; Koyama, Satoshi; Kataoka, Hideyuki; Kitano, Hiroya; Takeuchi, Hiromi

    2017-01-18

    The reflex cough test is useful for detecting silent aspiration, a risk factor for aspiration pneumonia. However, assessing the risk of aspiration pneumonia requires measuring not only the cough reflex but also cough strength. Currently, no reflex cough testing device is available that can directly measure reflex cough strength. We therefore developed a new testing device that can easily and simultaneously measure cough strength and the time until the cough reflex, and verified whether screening with this new instrument is feasible for evaluating the risk of aspiration pneumonia. This device consists of a special pipe with a double lumen, a nebulizer, and an electronic spirometer. We used a solution of prescription-grade L-tartaric acid to initiate the cough reflex. The solution was inhaled through a mouthpiece as a microaerosol produced by an ultrasonic nebulizer. The peak cough flow (PCF) of the induced cough was measured with the spirometer. The 70 patients who participated in this study comprised 49 patients without a history of pneumonia (group A), 21 patients with a history of pneumonia (group B), and 10 healthy volunteers (control group). With the novel device, PCF and time until cough reflex could be measured without adverse effects. The PCF values were 118.3 ± 64.0 L/min, 47.7 ± 38.5 L/min, and 254.9 ± 83.8 L/min in group A, group B, and the control group, respectively. The PCF of group B was significantly lower than that of group A and the control group (p reflex was 4.2 ± 5.9 s, 7.0 ± 7.0 s, and 1 s in group A, group B, and the control group, respectively. This duration was significantly longer for groups A and B than for the control group (A: p reflex and the strength of involuntary coughs for assessment of patients at risk of aspiration pneumonia.

  4. Validity and Reliability of the Alcohol, Smoking, and Substance Involvement Screening Test (ASSIST) in University Students.

    Science.gov (United States)

    Tiburcio Sainz, Marcela; Rosete-Mohedano, Ma Guadalupe; Natera Rey, Guillermina; Martínez Vélez, Nora Angélica; Carreño García, Silvia; Pérez Cisneros, Daniel

    2016-03-02

    The Alcohol, Smoking and Substance Involvement Screening Test (ASSIST), developed by the World Health Organization (WHO), has been used successfully in many countries, but there are few studies of its validity and reliability for the Mexican population. The objective of this study was to determine the psychometric properties of the self-administered ASSIST test in university students in Mexico. This was an ex post facto non-experimental study with 1,176 undergraduate students, the majority women (70.1%) aged 18-23 years (89.5%) and single (87.5%). To estimate concurrent validity, factor analysis and tests of reliability and correlation were carried out between the subscale for alcohol and AUDIT, those for tobacco and the Fagerström Test, and those for marijuana and DAST-20. Adequate reliability coefficients were obtained for ASSIST subscales for tobacco (alpha = 0.83), alcohol (alpha = 0.76), and marijuana (alpha = 0.73). Significant correlations were found only with the AUDIT (r = 0.71) and the alcohol subscale. The best balance of sensitivity and specificity of the alcohol subscale (83.8% and 80%, respectively) and the largest area under the ROC curve (81.9%) was found with a cutoff score of 8. The self-administered version of ASSIST is a valid screening instrument to identify at-risk cases due to substance use in this population.

  5. Isopropyl alcohol tank installed at A-3 Test Stand

    Science.gov (United States)

    2009-01-01

    An isopropyl alcohol (IPA) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen IPA, water and liquid oxygen (LOX) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  6. A novel non-invasive electrochemical biosensing device for in situ determination of the alcohol content in blood by monitoring ethanol in sweat.

    Science.gov (United States)

    Gamella, M; Campuzano, S; Manso, J; González de Rivera, G; López-Colino, F; Reviejo, A J; Pingarrón, J M

    2014-01-02

    A non-invasive, passive and simple to use skin surface based sensing device for determining the blood's ethanol content (BAC) by monitoring transdermal alcohol concentration (TAC) is designed and developed. The proposed prototype is based on bienzyme amperometric composite biosensors that are sensitive to the variation of ethanol concentration. The prototype correlates, through previous calibration set-up, the amperometric signal generated from ethanol in sweat with its content in blood in a short period of time. The characteristics of this sensor device permit determination of the ethanol concentration in isolated and in continuous form, giving information of the BAC of a subject either in a given moment or its evolution during long periods of time (8h). Moreover, as the measurements are performed in a biological fluid, the evaluated individual is not able to alter the result of the analysis. The maximum limit of ethanol in blood allowed by legislation is included within the linear range of the device (0.0005-0.6 g L(-1)). Moreover, the device shows higher sensitivity than the breathalyzers marketed at the moment, allowing the monitoring of the ethanol content in blood to be obtained just 5 min after ingestion of the alcoholic drink. The comparison of the obtained results using the proposed device in the analysis of 40 volunteers with those provided by the gas chromatographic reference method for determination of BAC pointed out that there were no significant differences between both methods. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Saliva and gastrointestinal functions of mastication, taste and textural perception, swallowing and initial digestion

    DEFF Research Database (Denmark)

    Pedersen, Anne Marie Lynge; Sørensen, Christiane E; Proctor, Gordon

    2018-01-01

    pattern. This review paper provides insight into the mechanisms by which saliva acts in relation to taste, mastication, bolus formation, enzymatic digestion, and swallowing. Also the protective functions of saliva including maintenance of dental and mucosal integrity will be discussed as they indirectly......Saliva exerts multiple functions in relation to the initial digestive processes taking place in the upper parts of the gastrointestinal tract. Ingestion of food and beverages, in turn, is a strong stimulus for secretion of saliva with a differential composition depending on the neuronal stimulation...... influence the digestive process. The final part of this paper focuses on the implications of xerostomia and salivary gland dysfunction on gastrointestinal functions. This article is protected by copyright. All rights reserved....

  8. Effect of saliva contamination on bond strength witha hydrophilic composite resin

    Directory of Open Access Journals (Sweden)

    Mauren Bitencourt Deprá

    2013-02-01

    Full Text Available OBJECTIVE: To evaluate the influence of saliva contamination on the bond strength of metallic brackets bonded to enamel with hydrophilic resin composite. METHODS: Eighty premolars were randomly divided into 4 groups (n = 20 according to bonding material and contamination: G1 bonded with Transbond XT with no saliva contamination, G2 bonded with Transbond XT with saliva contamination, G3 bonded with Transbond Plus Color Change with no saliva contamination and G4 bonded with Transbond Plus Color Change with saliva contamination. The results were statistically analyzed (ANOVA/Tukey. RESULTS: The means and standard deviations (MPa were: G110.15 ± 3.75; G2 6.8 ± 2.54; G3 9.3 ± 3.36; G4 8.3 ± 2.95. The adhesive remnant index (ARI ranged between 0 and 1 in G1 and G4. In G2 there was a prevalence of score 0 and similar ARI distribution in G3. CONCLUSION: Saliva contamination reduced bond strength when Transbond XT hydrophobic resin composite was used. However, the hydrophilic resin Transbond Plus Color Change was not affected by the contamination.OBJETIVO: avaliar a influência da contaminação por saliva na resistência de união de braquetes metálicos colados ao esmalte com um compósito resinoso hidrofílico. MÉTODOS: oitenta pré-molares foram divididos aleatoriamente em quatro grupos (n=20, de acordo com o material de colagem e a presença de contaminação - G1 colagem com Transbond XT na ausência de contaminação; G2 colagem com Transbond XT na presença de contaminação; G3 colagem com Transbond Plus Color Change na ausência de contaminação; G4 colagem com Transbond Plus Color Change na presença de contaminação. Os resultados foram tratados estatisticamente (ANOVA/Tukey. RESULTADOS: as médias e desvios-padrão (MPa foram G1 = 10,15 ± 3,75; G2 = 6,8 ± 2,54; G3 = 9,3 ± 3,36; G4 = 8,3 ± 2,95. O índice de adesivo remanescente (IAR variou entre 0 e 1 no G1 e no G4; no G2, houve predomínio do escore 0 e distribuição similar no

  9. Type testing of devices with inserted radioactive sources

    International Nuclear Information System (INIS)

    Rolle, A.; Droste, B.; Dombrowski, H.

    2006-01-01

    In Germany devices with inserted radioactive sources can get a type approval if they comply with specific requirements. Whoever operates a device whose type has been approved in accordance with the German Radiation Protection Ordinance does not need an individual authorization. Such type approvals for free use are granted by the Federal Office for Radiation Protection (B.f.S.) on the basis of type testing performed by the Physikalisch-Technische Bundesanstalt (P.T.B.), the national metrology institute, and the Bundesanstalt fur Materialforschung und -prufung (B.A.M.), the Federal Institute for Materials Research and Testing. Main aspects of the assessment are the activity of the radioactive sources, the dose equivalent rate near the devices, the tamper-proofness and leak-tightness of the sources and the safety of the construction of the devices. With the new Radiation Protection Ordinance in 2001, more stringent requirements for a type approval were established. Experiences with the new regulations and the relevant assessment criteria applied by P.T.B. and B.A.M. will be presented. (authors)

  10. Generic testability and test methods guidelines for ASIC devices

    International Nuclear Information System (INIS)

    Puri, K.; Takeda, H.

    1996-04-01

    Many industries are switching from analog equipment to digital equipment. This change has become desirable because digital devices have become cost-effective, easily available, highly reliable, easy to qualify and easy to test and replace when needed. The nuclear power industry is beginning to upgrade some of its instrumentation and control equipment from an analog design to digital design. A digital application specific integrated circuit (ASIC) device can be designed to perform the same functions as performed by analog modules. However, the ASIC must be designed for cost-effective testability and qualification. This report provides generic guidelines for designing cost-effective methods for testing and characterizing ASIC devices to accomplish qualification

  11. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection.

    Science.gov (United States)

    Dordević, Snezana; Kilibarda, Vesna; Stojanović, Tomislav

    2009-05-01

    Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Separation of the drug from matrix is achieved by reversed-phase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1) at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10) using chlorophorm. Calibration curves were in the range 0.1-5 microg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD) of carbamazepine in serum and saliva were 0.166 and 0.178 microg/mL, respectively. Limits of quantification (LOQ) in the serum and saliva were 0.237 and 0.226 microg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001). The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  12. Estimating children's exposure to toxic elements in contaminated toys and children's jewelry via saliva mobilization.

    Science.gov (United States)

    Guney, Mert; Nguyen, Alain; Zagury, Gerald J

    2014-09-19

    Children's potential for exposure to potentially toxic elements in contaminated jewelry and toys via mouth contact has not yet been fully evaluated. Various toys and jewelry (metallic toys and jewelry [MJ], plastic toys, toys with paint or coating, and brittle/pliable toys; n = 32) were tested using the saliva extraction (mouthing) compartment of the DIN and RIVM bioaccessibility protocols to assess As, Ba, Cd, Cr, Cu, Mn, Ni, Pb, Sb, and Se mobilization via saliva. Total concentrations of As, Cd, Cu, Ni, Pb, and Sb were found elevated in analyzed samples. Four metals were mobilized to saliva from 16 MJ in significant quantities (>1 μg for highly toxic Cd and Pb, >10 μg for Cu and Ni). Bioaccessible concentrations and hazard index values for Cd exceeded limit values, for young children between 6 mo- and 3 yr-old and according to both protocols. Total and bioaccessible metal concentrations were different and not always correlated, encouraging the use of bioaccessibility for more accurate hazard assessments. Bioaccessibility increased with increasing extraction time. Overall, the risk from exposure to toxic elements via mouthing was high only for Cd and for MJ. Further research on children's exposure to toxic elements following ingestion of toy or jewelry material is recommended.

  13. Therapeutic drug monitoring of caffeine in preterm infants: Could saliva be an alternative to serum?

    Science.gov (United States)

    Chaabane, Amel; Chioukh, Fatma Z; Chadli, Zohra; Ben Fredj, Nadia; Ben Ameur, Karim; Ben Hmida, Hayet; Boughattas, Naceur A; Monastiri, Kamel; Aouam, Karim

    2017-12-01

    Evaluate whether saliva could be a useful alternative to serum for routine therapeutic drug monitoring of caffeine in preterm infants using the enzyme multiplied immunoassay technique (EMIT) assay. We conducted a prospective study including preterm infants (less than 34 weeks' amenorrhea) admitted to the intensive care and neonatal medicine department. All infants received 5, 10, 15, 20 and 25mg/kg/day of citrate caffeine intravenously from the first to the fifth day of birth, respectively. For each patient, two concomitant blood and saliva samples corresponding to the trough concentrations were collected 24hours after each caffeine dose. The caffeine concentrations were determined using the EMIT ® 2000 caffeine assay. Thirteen preterm infants were included. The saliva and the serum caffeine concentration increased proportionally to the administered dose. Saliva and serum kinetics were comparable and the saliva caffeine concentrations were correlated to the serum ones (r 2 =0.76). Saliva caffeine monitoring by EMIT is a valid, useful and safe alternative to serum in preterm infants. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  14. Number of Streptococcus mutans and Lactobacillus in saliva versus the status of cigarette smoking, considering duration of smoking and number of cigarettes smoked daily.

    Science.gov (United States)

    Nakonieczna-Rudnicka, Marta; Bachanek, Teresa

    2017-09-21

    A large number of colonies of Streptococcus mutans (SM) and Lactobacillus (LB) cariogenic bacteria in the saliva show a high risk of dental caries development. Cotinine is a biomarker of exposure to the tobacco smoke. The aim of the study was assessment of the number of Streptococcus mutans and Lactobacillus in the saliva of non-smokers and smokers considering the duration of smoking and the number of cigarettes smoked daily. The number of SM and LB was analysed in relation to the frequency of oral health check-ups. The investigated group comprised 124 people aged 20-54. 58 (46.8%) reported cigarette smoking; 66 (53.2%) reported they had never smoked cigarettes and had never attempted to smoke. Cotinine concentration in the saliva was assayed using the Cotinine test (Calbiotech), and the number of SM and LB with the use of the CRT bacteria test (Ivoclar Vivadent, Liechtenstein). Statistical analysis was conducted using Chi2 and Mann-Whitney tests. Test values of pSM and LB and the status of smoking, the number of cigarettes smoked daily and duration of cigarette smoking. Smokers who reported having dental check-ups at least once a year significantly more frequently had a small number of LB stated in relation to people who had dental check-ups to control their oral health less frequently than once a year. The number of SM and LB in saliva does not depend on the smoking status, the number of cigarettes smoked daily and duration of smoking.

  15. Incidence of Epstein-Barr Virus in Astronaut Saliva During Spaceflight

    Science.gov (United States)

    Payne, Deborah A.; Mehta, Satish K.; Tyring, Stephen K.; Stowe, Raymond P.; Pierson, Duane L.

    1998-01-01

    Astronauts experience psychological and physical stresses that may result in re-activation of latent viruses during spaceflight, potentially increasing the risk of disease among crew members. The shedding of Epstein-Barr virus (EBV) in the saliva of astronauts will increase during spaceflight. A total of 534 saliva specimens were collected from 11 EBV-seropositive astronauts before, during, and after four space shuttle missions. The presence of EBV DNA in saliva, assessed by polymerase chain reaction (PCR), was used to determine shedding patterns before, during, and after spaceflight. EBV DNA was detected more frequently before flight than during (p less than 0.001) or after (p less than 0.01) flight. No significant difference between the in-flight and postflight periods was detected in the frequency of occurrence of EBV DNA. The increased frequency of shedding of EBV before flight suggests that stress levels may be greater before launch than during or after spaceflight.

  16. Improving ambulatory saliva-sampling compliance in pregnant women: a randomized controlled study.

    Directory of Open Access Journals (Sweden)

    Julian Moeller

    Full Text Available OBJECTIVE: Noncompliance with scheduled ambulatory saliva sampling is common and has been associated with biased cortisol estimates in nonpregnant subjects. This study is the first to investigate in pregnant women strategies to improve ambulatory saliva-sampling compliance, and the association between sampling noncompliance and saliva cortisol estimates. METHODS: We instructed 64 pregnant women to collect eight scheduled saliva samples on two consecutive days each. Objective compliance with scheduled sampling times was assessed with a Medication Event Monitoring System and self-reported compliance with a paper-and-pencil diary. In a randomized controlled study, we estimated whether a disclosure intervention (informing women about objective compliance monitoring and a reminder intervention (use of acoustical reminders improved compliance. A mixed model analysis was used to estimate associations between women's objective compliance and their diurnal cortisol profiles, and between deviation from scheduled sampling and the cortisol concentration measured in the related sample. RESULTS: Self-reported compliance with a saliva-sampling protocol was 91%, and objective compliance was 70%. The disclosure intervention was associated with improved objective compliance (informed: 81%, noninformed: 60%, F(1,60  = 17.64, p<0.001, but not the reminder intervention (reminders: 68%, without reminders: 72%, F(1,60 = 0.78, p = 0.379. Furthermore, a woman's increased objective compliance was associated with a higher diurnal cortisol profile, F(2,64  = 8.22, p<0.001. Altered cortisol levels were observed in less objective compliant samples, F(1,705  = 7.38, p = 0.007, with delayed sampling associated with lower cortisol levels. CONCLUSIONS: The results suggest that in pregnant women, objective noncompliance with scheduled ambulatory saliva sampling is common and is associated with biased cortisol estimates. To improve sampling compliance, results suggest

  17. The management of xerostomia in patients on haemodialysis: comparison of artificial saliva and chewing gum.

    Science.gov (United States)

    Bots, Casper P; Brand, Henk S; Veerman, Enno C I; Valentijn-Benz, Marianne; Van Amerongen, Barbara M; Nieuw Amerongen, Arie V; Valentijn, Robert M; Vos, Pieter F; Bijlsma, Joost A; Bezemer, Pieter D; ter Wee, Piet M

    2005-04-01

    Many patients on haemodialysis (HD) therapy suffer from a dry mouth and xerostomia. This can be relieved by mechanical and gustatory stimulation or palliative care. The aim of this crossover study was to investigate the effect and preferences of a sugar-free chewing gum (Freedent White) and a xanthan gum-based artificial saliva (Xialine) in the management of xerostomia in chronic HD patients. Sixty-five HD patients participated in a 6-week crossover trial. The artificial saliva was rated significantly lower than the chewing gum for effectiveness, taste and a global assessment. No preference differences were found for gender and age, although older subjects rated the artificial saliva with a higher mark. Thirty-nine subjects (60%) preferred chewing gum, 15% (n=10) preferred the artificial saliva. Therefore, both chewing gum and artificial saliva could play an important role in the palliative care of xerostomia in HD patients.

  18. The effect of bonding agents on the microleakage of sealant following contamination with saliva

    Directory of Open Access Journals (Sweden)

    Askarizadeh Nahid

    2008-06-01

    Full Text Available Aims : An issue of concern in dentistry is the inadequacy of adhesion and proper sealing following restoration of a tooth, which can lead to marginal leakage. The aim of this study was to evaluate the effect of a bonding agent on the microleakage of a sealant material following contamination with saliva. Materials and Methods : In this experimental research, 48 sound premolars were divided into two groups. The first group received sealant without bonding and the other group was given sealant with bonding. After prophylaxis, the occlusal surfaces were etched with 37% phosphoric acid gel and the teeth were then placed in fresh human saliva for l0 s. Following this, in the first group fissure sealant (Kerr was applied directly and cured; for the second group sealant was placed and cured after bonding (Single Bond; 3M. All samples were thermocycled (500 cycles; between 5°C and 55°C; dwell time of 30 s. Silver nitrate was used as the leakage tracer. The teeth were sectioned. Microleakage evaluation was made by stereomicroscope at 40x magnification and the results were evaluated with the Mann-Whitney U test. Results : In the group that received sealant without bonding extensive microleakage was seen; placement of sealant with bonding significantly reduced microleakage. Conclusion : In the presence of contamination with saliva, use of bonding under the fissure sealant can reduce microleakage

  19. [Quantity research on epidermal growth factor in saliva and epidermal growth factor receptor in biopsy samples of recurrent aphthous ulcer patients].

    Science.gov (United States)

    Gu, Yang; Zhang, Gang; Lin, Mei

    2008-02-01

    To examine the change of epidermal growth factor (EGF) concentration in saliva of recurrent aphthous ulcer (RAU) patients during the ulcerous and interval period and epidermal growth factor receptor (EGFR) in ulcer biopsy samples. ECF data of the samples, which were 27 saliva samples from RAU gained not only in the ulcerous period but also in interval period and 33 ones from normal persons, were acquired through enzyme linked immunosorhent assay (ELISA) and EGF standard curve. ECFR-RNA date of RAU biopsies, which were 31 biopsy samples from RAU got during the ulcerous period and 35 ones from normal persons, were surveyed by QF-RT-PCR. All RAU samples were obtained under the same level, which were the whole patients were minor aphthous ulcers and their ulcers occurred not over the first four days. All patients and normal persons were selected seriously under the rule of physical situations without any other diseases and histories of using medicines. The EGF concentration of saliva in RAU group at ulcer occurrence was higher than that in the interval period and the normal control with a significant test (F = 3.24, P ulcer occurrence was higher than the normal control with a significant test (t = 3.15, P ulcer occasion of RAU patients could be related with the decreasing of EGF in saliva during interval period, and that the ulcer sell-cure of RAU patients would be contributed to

  20. Interactions between resin monomers and commercial composite resins with human saliva derived esterases.

    Science.gov (United States)

    Jaffer, F; Finer, Y; Santerre, J P

    2002-04-01

    Cholesterol esterase (CE) and pseudocholinesterase (PCE) have been reported to degrade commercial and model composite resins containing bisphenylglycidyl dimethacrylate (BisGMA), triethylene glycol dimethacrylate (TEGDMA) or the latter in combination with urethane modified BisGMA monomer systems. In addition, human saliva has been shown to contain esterase like activities similar to CE and PCE. Hence, it was the aim of the current study to determine to what extent human saliva could degrade two common commercial composite resins (Z250 from 3M Inc. and Spectrum TPH from L.D. Caulk) which contain the above monomer systems. Saliva samples from different volunteers were collected, processed, pooled, and freeze-dried. TEGDMA and BisGMA monomers were incubated with human saliva derived esterase activity (HSDEA) and their respective hydrolysis was monitored using high performance liquid chromatography (HPLC). Both monomers were completely hydrolyzed within 25 h by HSDEA. Photopolymerized composites were incubated with buffer or human saliva (pH 7.0 and 37 C) for 2, 8 and 16 days. The incubation solutions were analyzed using HPLC and mass spectrometry. Surface morphology characterization was carried out using scanning electron microscopy. Upon biodegradation, the Z250 composite yielded higher amounts of BisGMA and TEGDMA related products relative to the TPH composite. However, there were higher amounts of ethoxylated bis-phenol A released from the TPH material. In terms of total mass of products released, human saliva demonstrated a greater ability to degrade Z250. In summary, HSDEA has been shown to contain esterase activities that can readily catalyze the biodegradation of current commercial composite resins.

  1. Kadar leptin saliva dan kejadian karies gigi anak obesitas (Salivary leptin levels and caries incidence in obese children

    Directory of Open Access Journals (Sweden)

    Elfrida Atzmaryanni

    2013-09-01

    Full Text Available Background: Children with obesity have a lower incidence of caries. Salivary leptin levels of obese children is higher than normal children. Leptin is protein hormone, contained in saliva. Salivary proteins maintain the balance of the ecosystem in the mouth. Purpose: The article was aimed to study the correlation of salivary leptin levels with caries incidence in obese children. Review: Mouth is reflection of the health status and so many changes occur as a weight gain. Child with obesity has a low incidence of caries than normal. This condition is associated with changes in oral cavity, especially the increase in salivary leptin. Caries is a disease of hard tissues cause by the activty of microorganisms, especially Streptococcus mutans. Salivary proteins maintain the balance of the ecosystem in the mouth. Leptin is a protein saliva, produced predominantly in adipose tissue and conduct active transport to saliva. Salivary leptin works in two ways: as an antimicrobial which prevents the attachment of bacteria on tooth surface or by inducing cytokine that affect the immune system in oral cavity. Conclusion: Salivary leptin is higher in obese children than in normal children. The low incidence of caries on obesity is associated with salivary leptin. Alteration in salivary composition and flow rate also decreased caries in obesity.Latar belakang: Anak yang mengalami obesitas memiliki insiden karies yang rendah. Kadar leptin saliva anak obesitas lebih tinggi dari anak normal. Leptin merupakan salah satu protein hormon yang terdapat di saliva. Protein saliva berfungsi untuk menjaga keseimbangan ekosistem di mulut. Tujuan: Artikel ini bertujuan mempelajari hubungan antara kadar leptin di dalam saliva dengan kejadian karies anak obesitas. Tinjauan pustaka: Rongga mulut merupakan cerminan dari status kesehatan dan banyak perubahan yang terjadi seiring peningkatan berat badan seseorang. Anak Obesitas memiliki insiden karies yang rendah jika dibandingkan

  2. Device for testing continuity and/or short circuits in a cable

    Science.gov (United States)

    Hayhurst, Arthur R. (Inventor)

    1995-01-01

    A device for testing current paths is attachable to a conductor. The device automatically checks the current paths of the conductor for continuity of a center conductor, continuity of a shield and a short circuit between the shield and the center conductor. The device includes a pair of connectors and a circuit to provide for testing of the conductive paths of the cable. The pair of connectors electrically connects the conductive paths of a cable to be tested with the circuit paths of the circuit. The circuit paths in the circuit include indicators to simultaneously indicate the results of the testing.

  3. Design of Ablation Test Device for Brick Coating of Gun

    Science.gov (United States)

    shirui, YAO; yongcai, CHEN; fei, WANG; jianxin, ZHAO

    2018-03-01

    As a result of the live ammunition test conditions, the barrel resistance of the barrel coating has high cost, time consuming, low efficiency and high test site requirements. This article designed a simple, convenient and efficient test device. Through the internal trajectory calculation by Matlab, the ablation environment produced by the ablation test device has achieved the expected effect, which is consistent with the working condition of the tube in the launching state, which can better reflect the ablation of the coating.

  4. Effect of masticatory stimulation on the quantity and quality of saliva and the salivary metabolomic profile.

    Directory of Open Access Journals (Sweden)

    Nobuyuki Okuma

    Full Text Available This study characterized the changes in quality and quantity of saliva, and changes in the salivary metabolomic profile, to understand the effects of masticatory stimulation.Stimulated and unstimulated saliva samples were collected from 55 subjects and salivary hydrophilic metabolites were comprehensively quantified using capillary electrophoresis-time-of-flight mass spectrometry.In total, 137 metabolites were identified and quantified. The concentrations of 44 metabolites in stimulated saliva were significantly higher than those in unstimulated saliva. Pathway analysis identified the upregulation of the urea cycle and synthesis and degradation pathways of glycine, serine, cysteine and threonine in stimulated saliva. A principal component analysis revealed that the effect of masticatory stimulation on salivary metabolomic profiles was less dependent on sample population sex, age, and smoking. The concentrations of only 1 metabolite in unstimulated saliva, and of 3 metabolites stimulated saliva, showed significant correlation with salivary secretion volume, indicating that the salivary metabolomic profile and salivary secretion volume were independent factors.Masticatory stimulation affected not only salivary secretion volume, but also metabolite concentration patterns. A low correlation between the secretion volume and these patterns supports the conclusion that the salivary metabolomic profile may be a new indicator to characterize masticatory stimulation.

  5. Meal-induced compositional changes in blood and saliva in persons with bulimia nervosa

    DEFF Research Database (Denmark)

    Dynesen, Anja Weirsøe; Jensen, Allan Bardow; Astrup, Arne

    2008-01-01

    in controls before and after intake of a meal and whether these changes may be reflected in saliva. Design: Twenty women with bulimia nervosa and 20 age- and sex-matched healthy controls participated. After an overnight fast, the subjects ate a standardized carbohydrate-rich breakfast. Whole saliva and blood...... were collected, and visual analogue scales for hunger and satiety were completed once before and continuously for 5 h after the breakfast. Results: A lower pre- and postprandial whole saliva flow rate was found in subjects with bulimia nervosa, which might have been attributable to a concomitant intake...

  6. Aerosol can puncture device operational test plan

    International Nuclear Information System (INIS)

    Leist, K.J.

    1994-01-01

    Puncturing of aerosol cans is performed in the Waste Receiving and Processing Facility Module 1 (WRAP 1) process as a requirement of the waste disposal acceptance criteria for both transuranic (TRU) waste and low-level waste (LLW). These cans have contained such things as paints, lubricating oils, paint removers, insecticides, and cleaning supplies which were used in radioactive facilities. Due to Westinghouse Hanford Company (WHC) Fire Protection concerns of the baseline system's fire/explosion proof characteristics, a study was undertaken to compare the baseline system's design to commercially available puncturing devices. While the study found no areas which might indicate a risk of fire or explosion, WHC Fire Protection determined that the puncturing system must have a demonstrated record of safe operation. This could be obtained either by testing the baseline design by an independent laboratory, or by substituting a commercially available device. As a result of these efforts, the commercially available Aerosolv can puncturing device was chosen to replace the baseline design. Two concerns were raised with the system. Premature blinding of the coalescing/carbon filter, due to its proximity to the puncture and draining operation; and overpressurization of the collection bottle due to its small volume and by blinding of the filter assembly. As a result of these concerns, testing was deemed necessary. The objective of this report is to outline test procedures for the Aerosolv

  7. Determination of carbamazepine in serum and saliva samples by high performance liquid chromatography with ultraviolet detection

    Directory of Open Access Journals (Sweden)

    Đorđević Snežana

    2009-01-01

    Full Text Available Background/Aim. Carbamazepine is antiepileptic drug widely used for the treatment of epilepsy. Due to low therapeutic index of carbamazepine there is a need for routine measuring its concentrations in biological fluids. The aim of the study was to describe a method for concomitant determination of carbamazepine in the serum and saliva. Methods. Separation of the drug from matrix is achieved by reversedphase chromatography on a C18 column, with a mobile phase of methanol-water-acetic acid (65:34:1 at a flow-rate of 1.0 ml/min. Detection was effected by ultra-violet absorption at 285 nm. The total run time was 5 min. Samples were prepared by alkaline extraction (pH 10 using chlorophorm. Results. Calibration curves were in the range 0.1-5 μg/mL for serum and saliva samples. Mean recoveries of spiked serum and saliva were 97.59 and 92.30%, respectively. Limits of detection (LOD of carbamazepine in serum and saliva were 0.166 and 0.178 μg/mL, respectively. Limits of quantification (LOQ in the serum and saliva were 0.237 and 0.226 μg/mL, respectively. The method precision was carried out with coefficient of variation of 2.10% and 4.03% for the serum and saliva, respectively. The obtained data showed that there was a strong correlation between saliva and serum concentrations (r = 0.9481, p < 0.001. Conclusion. The method described here is rapid, precise, accurate and simple, and can be used for quantitative determination of carbamazepine in human serum and saliva after therapy applying. Saliva samples could be used as an alternative matrix for therapeutic drug monitoring of this antiepileptic drug.

  8. Nicotine concentrations in urine and saliva of smokers and non-smokers.

    Science.gov (United States)

    Feyerabend, C; Higenbottam, T; Russell, M A

    1982-01-01

    Nicotine concentrations were measured in saliva and urine samples collected from 82 smokers and 56 non-smokers after a morning at work. Each subject answered a series of questions related to their recent intentional or passive exposure to tobacco smoke. All non-smokers had measurable amounts of nicotine in both saliva and urine. Those non-smokers who reported recent exposure to tobacco smoke had significantly higher nicotine concentrations (p less than 0.001) than those who had not been exposed; their concentrations overlapped those of smokers who had smoked up to three cigarettes before sampling had the greatest influence on nicotine concentrations (r=0.62 for saliva and r=0.51 for urine). Neither the nicotine for yield of cigarettes nor the self-reported degree of inhalation had any significant effect on nicotine concentrations. PMID:6802384

  9. Determination of epirubicin and its metabolite epirubicinol in saliva and plasma by HPLC

    NARCIS (Netherlands)

    Dodde, WIW; Maring, JG; Hendriks, G; Wachters, FM; Groen, HJM; de Vries, EGE; Uges, DRA

    We present a high-performance liquid chromatography (HPLC) method suitable for the analysis of epirubicin and its metabolite epirubicinol in saliva and plasma. Preparation of saliva and plasma samples was performed by extraction of analytes with a chloroform: 2-propanol mixture (6:1, vol/vol) and

  10. Corticosteroids in plasma and saliva : the influence of oral contraceptive use and pregnancy

    NARCIS (Netherlands)

    Meulenberg, E.P.M.M.

    1995-01-01

    Cortisol in saliva is considered to be derived from the free, unbound fraction in plasma by simple diffusion through the salivary gland. Despite considerable conversion into cortisone in the salivary gland by the enzyme 11β-hydroxysteroid dehydrogenase, levels of cortisol in saliva form a

  11. Fluoride level in saliva after bonding orthodontic brackets with a fluoride containing adhesive

    NARCIS (Netherlands)

    Ogaard, B; Arends, J; Helseth, H; Dijkman, G; vanderKuijl, M

    The fluoride level in saliva is considered an important parameter in caries prevention. Elevation of the salivary fluoride level by a fluoride-releasing orthodontic bonding adhesive would most likely be beneficial in the prevention of enamel caries. In this study, the fluoride level in saliva was

  12. Fourier Transform Infrared Spectroscopy and Photoacoustic Spectroscopy for Saliva Analysis.

    Science.gov (United States)

    Mikkonen, Jopi J W; Raittila, Jussi; Rieppo, Lassi; Lappalainen, Reijo; Kullaa, Arja M; Myllymaa, Sami

    2016-09-01

    Saliva provides a valuable tool for assessing oral and systemic diseases, but concentrations of salivary components are very small, calling the need for precise analysis methods. In this work, Fourier transform infrared (FT-IR) spectroscopy using transmission and photoacoustic (PA) modes were compared for quantitative analysis of saliva. The performance of these techniques was compared with a calibration series. The linearity of spectrum output was verified by using albumin-thiocyanate (SCN(-)) solution at different SCN(-) concentrations. Saliva samples used as a comparison were obtained from healthy subjects. Saliva droplets of 15 µL were applied on the silicon sample substrate, 6 drops for each specimen, and dried at 37 ℃ overnight. The measurements were carried out using an FT-IR spectrometer in conjunction with an accessory unit for PA measurements. The findings with both transmission and PA modes mirror each other. The major bands presented were 1500-1750 cm(-1) for proteins and 1050-1200 cm(-1) for carbohydrates. In addition, the distinct spectral band at 2050 cm(-1) derives from SCN(-) anions, which is converted by salivary peroxidases to hypothiocyanate (OSCN(-)). The correlation between the spectroscopic data with SCN(-) concentration (r > 0.990 for transmission and r = 0.967 for PA mode) was found to be significant (P < 0.01), thus promising to be utilized in future applications. © The Author(s) 2016.

  13. A Qualitative Review on the Pharmacokinetics of Antibiotics in Saliva: Implications on Clinical Pharmacokinetic Monitoring in Humans.

    Science.gov (United States)

    Kiang, Tony K L; Ensom, Mary H H

    2016-03-01

    We conducted a systematic search to describe the current state of knowledge regarding the utility of saliva for clinical pharmacokinetic monitoring (CPM) of antibiotics. Although the majority of identified studies lacked sufficient pharmacokinetic data needed to assign an appropriate suitability classification, most aminoglycosides, fluoroquinolones, macrolides, penicillins/cephalosporins, and tetracyclines are likely not suitable for CPM in saliva. No clear pattern of correlation was observed between physiochemical properties that favor drug distribution into saliva and the likelihood of the antibiotic being classified as suitable for CPM in saliva (and vice versa). Insufficient data were available to determine if pathophysiological conditions affected salivary distribution of antibiotics. Additional confirmatory data are required for drugs (especially in patients) that are deemed likely suitable for CPM in saliva because only a few studies were available and many focused only on healthy subjects. All studies identified had relatively small sample sizes and exhibited large variability. Very few studies reported salivary collection parameters (e.g., salivary flow, pH) that could potentially have some impact on drug distribution into saliva. The available data are heavily weighted on healthy subjects, and insufficient data were available to determine if pathophysiology had effects on saliva drug distribution. Some studies also lacked assay sensitivity for detecting antibiotics in saliva. Overall, this review can be useful to clinicians who desire an overview on the suitability of saliva for conducting CPM of specific antibiotics, or for researchers who wish to fill the identified knowledge gaps to move the science of salivary CPM further.

  14. Effect of Different Saliva Decontamination Procedures on Bond Strength to Dentin in Single Bottle Systems

    Directory of Open Access Journals (Sweden)

    M. Ghavam

    2004-09-01

    seconds for 500 cycles. Finally, samples were sheared using Instron testing machine andshear bond strength data were subjected to one way ANOVA analysis, and Tukey HSD PostHoc. Mode of failure of samples was examined under Stereomicroscope (×40 and using Log-rank survival data analysis.Results: No statistically difference between mean shear bond strength of groups 1,2,3 was observed (P=0.543. Comparison of groups 4,5,6 with group 1 showed that shear bond strength of group 4 was significantly lower (P<0.001. Mean shear bond strength of groups1,7,8,9 were not significantly different (P=0.150. The major mode of failure was cohesive either in composite or dentin bonding.Conclusion: Blot- drying of saliva-contaminated uncured Single-bottle adhesive significantly decreased shear bond strength of composite to dentin. In other contamination protocols, the effect of treatments applied did not differ.

  15. Perbandingan Jumlah Koloni Bakteri Saliva pada Anak-Anak Karies dan Non Karies Setelah Mengkonsumsi Minuman Berkarbonasi

    Directory of Open Access Journals (Sweden)

    Rendra Chriestedy Prasetya

    2013-07-01

    Full Text Available Dental caries and periodontal disease are well established and common in Indonesia, and both of these diseases are major concerns for the oral and dental health. The objective of this study was to compare the differences in children with and without caries in terms of colony bacteria in the saliva, and the changes before and after consumption of carbonated drink. The study was conducted on Al-Qodiri elementary school students who were 10-12 years old. Saliva was collected before and after consumption (for 2 min of a carbonated drink. T-test was used to analyze the results. The results of the study showed that there was a significant difference (p<0.05 between the caries and non-caries groups.DOI: 10.14693/jdi.v15i1.86

  16. I drink therefore I am: validating alcohol-related implicit association tests

    NARCIS (Netherlands)

    Lindgren, K.P.; Neighbors, C.; Teachman, B.A.; Wiers, R.W.; Westgate, E.; Greenwald, A.G.

    2013-01-01

    There is an imperative to predict hazardous drinking among college students. Implicit measures have been useful in predicting unique variance in drinking and alcohol-related problems. However, they have been developed to test different theories of drinking and have rarely been directly compared with

  17. A Population Pharmacokinetic Model for Disposition in Plasma, Saliva and Urine of Scopolamine after Intranasal Administration to Healthy Human Subjects

    Science.gov (United States)

    Wu, L.; Tam, V. H.; Chow, D. S. L.; Putcha, L.

    2014-01-01

    An intranasal gel formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness. The bioavailability and pharmacokinetics (PK) were evaluated under the Food and Drug Administration guidelines for clinical trials with an Investigative New Drug (IND) protocol. The aim of this project was to develop a PK model that can predict the relationship between plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trials with INSCOP. Methods: Twelve healthy human subjects were administered three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min and 24 h after dosing and scopolamine concentrations were measured by using a validated LC-MS-MS assay. Pharmacokinetic Compartmental models, using actual dosing and sampling times, were built using Phoenix (version 1.2). Model selection was based on the likelihood ratio test on the difference of criteria (-2LL) and comparison of the quality of fit plots. Results: The best structural model for INSCOP (minimal -2LL= 502.8) was established. It consisted of one compartment each for plasma, saliva and urine, respectively, which were connected with linear transport processes except the nonlinear PK process from plasma to saliva compartment. The best-fit estimates of PK parameters from individual PK compartmental analysis and Population PK model analysis were shown in Tables 1 and 2, respectively. Conclusion: A population PK model that could predict population and individual PK of scopolamine in plasma, saliva and urine after dosing was developed and validated. Incorporating a non-linear transfer from plasma to saliva compartments resulted in a significantly improved model fitting. The model could be used to predict scopolamine plasma concentrations from salivary and urinary drug levels, allowing non-invasive therapeutic monitoring of scopolamine in space and other remote environments.

  18. Zika virus infection spread through saliva – a truth or myth?

    Directory of Open Access Journals (Sweden)

    Walter Luiz SIQUEIRA

    2016-01-01

    Full Text Available Abstract In this Point-of-view article we highlighted some features related to saliva and virus infection, in special for zika virus. In addition, we pointed out the potential oral problems caused by a microcephaly originated by a zika virus infection. In the end the, we demonstrated the importance of a more comprehensive exploration of saliva and their components as a fluid for diagnostic and therapeutic approaches on oral and systemic diseases.

  19. Bond Strength of a Bisphenol-A-Free Fissure Sealant With and Without Adhesive Layer under Conditions of Saliva Contamination.

    Science.gov (United States)

    Mesquita-Guimarães, Késsia Suênia Fidelis de; Sabbatini, Iliana Ferraz; Almeida, Cintia Guimarães de; Galo, Rodrigo; Nelson-Filho, Paulo; Borsatto, Maria Cristina

    2016-01-01

    Dental sealants are important for prevention of carious lesions, if they have good shear strength. The aim of this study was to evaluate the shear bond strength (SBS) of two sealants to saliva-contaminated and non-contaminated enamel with and without an intermediate adhesive layer underneath the sealant. Ninety flat enamel surfaces from human third molars were randomly assigned to 6 groups (n=15): F (control): Fluroshield(tm) sealant; EWB (control): Embrace(tm) WetBond(tm); SB/F: Single Bond adhesive system + F; SB/EWB, s-SB/F and s-SB/EWB. In the s-SB/F and s-SB/EWB groups, the acid-etched enamel was contaminated with 0.01 mL of fresh human saliva for 20 s. Sealant cylinders were bonded to enamel surface with and without an intermediate adhesive system layer. The shear tests were performed using a universal testing machine (0.5 mm/min). Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney tests (α=0.05). F presented higher mean SBS than EWB in all experimental conditions. The lowest SBS mean was obtained for EWB on contaminated enamel (p<0.05). In conclusion, an adhesive system layer should be used prior to sealant placement, in both dry and saliva-contaminated enamel. F had the best performance in all experimental conditions. EWB sealant showed very low results, but an adhesive layer underneath the sealant increased its SBS even after salivary contamination.

  20. An alcohol withdrawal test battery measuring multiple behavioral symptoms in mice.

    Science.gov (United States)

    Metten, Pamela; Schlumbohm, Jason P; Huang, Lawrence C; Greenberg, Gian D; Hack, Wyatt R; Spence, Stephanie E; Crabbe, John C

    2018-05-01

    Despite acceptance that risk for alcohol-use disorder (AUD) has a large genetic component, the identification of genes underlying various components of risk for AUD has been hampered in humans, in part by the heterogeneity of expression of the phenotype. One aspect of AUD is physical dependence. Alcohol withdrawal is a serious consequence of alcohol dependence with multiple symptoms, many of which are seen in multiple species, and can be experienced over a wide-ranging time course. In the present three studies, we developed a battery of withdrawal tests in mice, examining behavioral symptoms from multiple domains that could be measured over time. To permit eventual use of the battery in different strains of mice, we used male and female mice of a genetically heterogeneous stock developed from intercrossing eight inbred strains. Withdrawal symptoms were assessed using commonly used tests after administration of ethanol in vapor for 72 continuous hours. We found significant effects of ethanol withdrawal versus air-breathing controls on nearly all symptoms, spanning 4 days following ethanol vapor inhalation. Withdrawal produced hypothermia, greater neurohyperexcitability (seizures and tremor), anxiety-like behaviors using an apparatus (such as reduced transitions between light and dark compartments), anhedonia (reduced sucrose preference), Straub tail, backward walking, and reductions in activity; however, there were no changes in thermal pain sensitivity, hyper-reactivity to handling, or anxiety-like emergence behaviors in other apparatus. Using these data, we constructed a refined battery of withdrawal tests. Individual differences in severity of withdrawal among different tests were weakly correlated at best. This battery should be useful for identifying genetic influences on particular withdrawal behaviors, which should reflect the influences of different constellations of genes. Published by Elsevier Inc.

  1. A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva

    Directory of Open Access Journals (Sweden)

    Dong Geon Jung

    2017-11-01

    Full Text Available A lab-on-a-chip (LOC-based non-invasive optical sensor for measuring glucose in saliva was fabricated. Existing glucose sensors utilizing blood require acquisition of a blood sample by pricking the finger, which is painful and inconvenient. To overcome these limitations, we propose a non-invasive glucose sensor with LOC, micro-electro-mechanical system and optical measurement technology. The proposed sensor for measuring glucose in saliva involves pretreatment, mixing, and measurement on a single tiny chip. Saliva containing glucose and glucose oxidase for glucose oxidation are injected through Inlets 1 and 2, respectively. Next, H2O2 is produced by the reaction between glucose and glucose oxidase in the pretreatment part. The saliva and generated H2O2 are mixed with a colorizing agent injected through Inlet 3 during the mixing part and the absorbance of the colorized mixture is measured in the measurement part. The absorbance of light increases as a function of glucose concentration at a wavelength of 630 nm. To measure the absorbance of the colorized saliva, a light-emitting diode with a wavelength of 630 nm and a photodiode were used during the measurement part. As a result, the measured output current of the photodiode decreased as glucose concentration in the saliva increased.

  2. Orthodontic treatment effects on inflammatory marker profiles in saliva before and after 2 archwire changes

    Science.gov (United States)

    Yamamoto, Zulham; Jaafar, Ikmal Mohamad; Rohaya, M. A. W.; Abidin, Intan Zarina Zainol; Senafi, Sahidan; Ariffin, Zaidah Zainal; Ariffin, Shahrul Hisham Zainal

    2013-11-01

    Periodontal tissue changes exerted by external forces in orthodontic treatment allow tooth movement. The changes in periodontal tissues i.e. inflammation can be monitored using gingival crevicular fluid (GCF). GCF is a component of saliva. Saliva could be used to monitor periodontal disease progression. The use of saliva to monitor periodontal tissues changes during orthodontic treatment is still unknown. Therefore, we observed the profiles of inflammatory markers namely creatine kinase ('CK), nitric oxide (NO), lactate dehydrogenase (LDH) and aspartate aminotransferase (AST) in saliva of orthodontic patients to evaluate their importance in orthodontic treatment. A total of 21 subjects (13 female and 8 male) participated in this study. Samples were collected from gingival crevicular fluid at three period of archwire changes: baseline (M0), 2 weeks after 0.014" NiTi archwire (M1), and 2 weeks after 0.018" NiTi archwire (M2). All enzyme activities i.e. CK, LDH and AST were measured spectrophotometrically at 340 nm. Griess assay was used to measure nitric oxide level. CK activity, NO level, LDH activity and AST activity in saliva samples did not show significant differences among period of archwire changes. The use of inflammatory marker profiles in saliva may not represent the changes in periodontal tissues during orthodontic treatment.

  3. Changes in the Concentration of Ions in Saliva and Dental Plaque after Application of CPP-ACP with and without Fluoride among 6-9 Year Old Children.

    Science.gov (United States)

    Poureslami, H; Hoseinifar, Ra; Khazaeli, P; Hoseinifar, Re; Sharifi, H; Poureslami, P

    2017-03-01

    The casein phospho peptide-amorphous calcium phosphate with or without fluoride (CPP-ACPF and CPP-ACP respectively) are of considerably new materials which are highly recommended for prevention of dental caries. However, there is a shortage in literature on how they affect the ion concentration of saliva or dental plaque. The aim of this study was to evaluate the concentration of calcium, phosphate and fluoride in the plaque and saliva of children with Early Childhood Caries (ECC) after applying the CPP-ACP paste in comparison with the use of CPP-ACPF paste. One ml of un-stimulated saliva of 25 preschool children was collected and then 1 mg of the plaque sample was collected from the buccal surfaces of the two first primary molars on the upper jaw. CPP-ACP as well as CPP-ACPF pastes were applied on the tooth surfaces in two separate steps. In steps, plaque and saliva sampling was performed after 60 minutes. The amount of calcium ions was measured by Atomic Absorption Device and the amount of phosphate and fluoride ions was measured by Ion Chromatography instrument. Data were analyzed using Repeated Measurements ANOVA at a p Application of both CPP-ACPF and CPP-ACP significantly increased the concentration of calcium, phosphate, and fluoride in both saliva and dental plaque. Moreover, significantly higher salivary fluoride concentration was seen after application of CPP-ACPF compared to CPP-ACP. No other significant difference was observed between these two materials. CPP-ACPF can be more useful than CPP-ACP in protecting the primary teeth against caries process, especially when there is poor hygiene.

  4. Characterisation of advanced glycation endproducts in saliva from patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Yoon, Min-Sung; Jankowski, Vera; Montag, Susanne; Zidek, Walter; Henning, Lars; Schlueter, Hartmut; Tepel, Martin; Jankowski, Joachim

    2004-01-01

    Patients with diabetes mellitus are prone to develop increased advanced glycation endproducts causing local complications and increased overall morbidity and mortality. Nuclear magnetic resonance spectra were determined in saliva of 52 consecutive patients with diabetes mellitus and 47 age-matched healthy control subjects. Resonance spectra showed specific peaks at 2.3, 7.3, and 8.4 ppm in saliva from patients with diabetes mellitus. These peaks could be generated by incubation of saliva from healthy control subjects with hypochloric acid in vitro, indicating the presence of advanced glycation endproducts. The presence of advanced glycation endproducts in patients with diabetes mellitus was associated with approximal plaque index, indicating increased periodontal damage. The study indicates that increased advanced glycation endproducts are involved in the pathogenesis of diabetic complications

  5. Corrosion in artificial saliva of a Ni-Cr-based dental alloy joined by TIG welding and conventional brazing.

    Science.gov (United States)

    Matos, Irma C; Bastos, Ivan N; Diniz, Marília G; de Miranda, Mauro S

    2015-08-01

    Fixed prosthesis and partial dental prosthesis frameworks are usually made from welded Ni-Cr-based alloys. These structures can corrode in saliva and have to be investigated to establish their safety. The purpose of this study was to evaluate the corrosion behavior of joints joined by tungsten inert gas (TIG) welding and conventional brazing in specimens made of commercial Ni-Cr alloy in Fusayama artificial saliva at 37°C (pH 2.5 and 5.5). Eighteen Ni-Cr base metal specimens were cast and welded by brazing or tungsten inert gas methods. The specimens were divided into 3 groups (base metal, 2 welded specimens), and the composition and microstructure were qualitatively evaluated. The results of potential corrosion and corrosion current density were analyzed with a 1-way analysis of variance and the Tukey test for pairwise comparisons (α=.05). Base metal and tungsten inert gas welded material showed equivalent results in electrochemical corrosion tests, while the air-torched specimens exhibited low corrosion resistance. The performance was worst at pH 2.5. These results suggest that tungsten inert gas is a suitable welding process for use in dentistry, because the final microstructure does not reduce the corrosion resistance in artificial saliva at 37°C, even in a corrosion-testing medium that facilitates galvanic corrosion processes. Moreover, the corrosion current density of brazed Ni-Cr alloy joints was significantly higher (P<.001) than the base metal and tungsten inert gas welded joints. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Unstimulated salivary flow rate, pH and buffer capacity of saliva in healthy volunteers Débito basal, pH y capacidad tampón de la secreción salivar en sujetos sanos

    OpenAIRE

    C. Fenoll-Palomares; J. V. Muñoz-Montagud; V. Sanchiz; B. Herreros; V. Hernández; M. Mínguez; A. Benages

    2004-01-01

    Objectives: to assess the salivary flow rate, pH, and buffer capacity of healthy volunteers, and their relationships with age, gender, obesity, smoking, and alcohol consumption, and to establish the lower-end value of normal salivary flow (oligosialia). Methods: a prospective study was conducted in 159 healthy volunteers (age > 18 years, absence of medical conditions that could decrease salivary flow). Unstimulated whole saliva was collected during ten minutes, and salivary flow rate (ml/min)...

  7. The effect of CPP-ACP-propolis chewing gum on calcium and phosphate ion release on caries-active subjects’ saliva and the formation of Streptococcus mutans biofilm

    Science.gov (United States)

    Hasnamudhia, F.; Bachtiar, E. W.; Sahlan, M.; Soekanto, S. A.

    2017-08-01

    The aim of this study was to analyze the effect of CPP-APP and propolis wax if they are combined in a chewing gum formulation, observed from the calcium and phosphate ion level released by CPP-ACP and the emphasis of Streptococcus mutans mass in the biofilm by propolis wax on caries-active subjects’ saliva. Chewing gum simulation was done in vitro on 25 caries-active subjects’ saliva using five concentrations of chewing gum (0% propolis + 0% CPP-ACP, 0% propolis + CPP-ACP, 2% propolis + CPP-ACP, 4% propolis + CPP-ACP, and 6% propolis + CPP-ACP) and was then tested using an atomic absorption spectrophotometer to analyze calcium ion levels, an ultraviolet-visible spectrophotometer to analyze phosphate ion levels, and a biofilm assay using crystal violet to analyze the decline in biofilm mass. After the chewing simulation, calcium ion levels on saliva+gum eluent increased significantly compared to the saliva control, with the highest calcium level released by CPP-ACP + 2% propolis chewing gum. There was an insignificant phosphate level change between the saliva control and saliva+gum eluent. There was also a significant decline of S. mutans biofilm mass in the saliva+gum eluent, mostly by the CPP-ACP chewing gum and CPP-ACP + 6% propolis. The CPP-ACP-propolis chewing gum simulation generated the largest increase in calcium and phosphate ion level and the largest decline in S. mutans biofilm mass.

  8. Estimation of Cutoff Values of Cotinine in Urine and Saliva for Pregnant Women in Poland

    Directory of Open Access Journals (Sweden)

    Joanna Stragierowicz

    2013-01-01

    Full Text Available Setting appropriate cutoff values and the use of a highly sensitive analytical method allow for correct classification of the smoking status. Urine-saliva pairs samples of pregnant women in the second and third trimester, and saliva only in the first trimester were collected. Offline SPE and LC-ESI-MS/MS method was developed in the broad concentration range (saliva 0.4–1000 ng/mL, urine 0.8–4000 ng/mL. The mean recoveries were 3.7±7.6% for urine and 99.1±2.6% for saliva. LOD for saliva was 0.12 ng/mL and for urine 0.05 ng/mL; LOQ was 0.4 ng/mL and 0.8 ng/mL, respectively. Intraday and interday precision equaled, respectively, 1.2% and 3.4% for urine, and 2.3% and 6.4% for saliva. There was a strong correlation between salivary cotinine and the uncorrected cotinine concentration in urine in the second and third trimesters of pregnancy. The cutoff values were established for saliva 12.9 ng/mL and urine 42.3 ng/mL or 53.1 μg/g creatinine with the ROC curve analysis. The developed analytical method was successfully applied to quantify cotinine, and a significant correlation between the urinary and salivary cotinine levels was found. The presented cut-off values for salivary and urinary cotinine ensure a categorization of the smoking status among pregnant women that is more accurate than self-reporting.

  9. A Test of the Salience Asymmetry Interpretation of the Alcohol-IAT

    NARCIS (Netherlands)

    Houben, K.; Wiers, R.W.H.J.

    2006-01-01

    K. Rothermund and D. Wentura (2004) showed how Figure-Ground (FG) asymmetries produce effects on the Implicit Association Task (IAT), independent of associations. Here, the FG account was tested for the robust finding that drinkers show a negative alcohol-IAT effect while being positive on explicit

  10. Development of the alcohol waste processing equipment

    International Nuclear Information System (INIS)

    Obara, Kiyoshi; Ooyama, Etsuo; Suzuki, Toshiaki; Oohara, Norikazu

    2004-01-01

    In the experimental fast Reactor JOYO, gripper of Fuel Handling Machine and Ex-Vessel Transfer Machine that the sodium adhered is being washed with alcohol. This radioactive alcohol waste that was used to the washing is stored to the tank. If it is able to separate the alcohol and sodium in the alcohol waste it becomes possible to dispose of the alcohol waste. Japan Nuclear Institute and Fuji Electric Systems CO., LTD. Developed the device that adds carbonic acid gas to the alcohol waste and cause the sodium in the alcohol waste separated as carbonate and remove this carbonate by using the thin film evaporator. (author)

  11. Prevalence of alcohol-impaired drivers based on random breath tests in a roadside survey in Catalonia (Spain).

    Science.gov (United States)

    Alcañiz, Manuela; Guillén, Montserrat; Santolino, Miguel; Sánchez-Moscona, Daniel; Llatje, Oscar; Ramon, Lluís

    2014-04-01

    Sobriety checkpoints are not usually randomly located by traffic authorities. As such, information provided by non-random alcohol tests cannot be used to infer the characteristics of the general driving population. In this paper a case study is presented in which the prevalence of alcohol-impaired driving is estimated for the general population of drivers. A stratified probabilistic sample was designed to represent vehicles circulating in non-urban areas of Catalonia (Spain), a region characterized by its complex transportation network and dense traffic around the metropolis of Barcelona. Random breath alcohol concentration tests were performed during spring 2012 on 7596 drivers. The estimated prevalence of alcohol-impaired drivers was 1.29%, which is roughly a third of the rate obtained in non-random tests. Higher rates were found on weekends (1.90% on Saturdays and 4.29% on Sundays) and especially at night. The rate is higher for men (1.45%) than for women (0.64%) and it shows an increasing pattern with age. In vehicles with two occupants, the proportion of alcohol-impaired drivers is estimated at 2.62%, but when the driver was alone the rate drops to 0.84%, which might reflect the socialization of drinking habits. The results are compared with outcomes in previous surveys, showing a decreasing trend in the prevalence of alcohol-impaired drivers over time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Corrosion resistance of titanium-containing dental orthodontic wires in fluoride-containing artificial saliva

    International Nuclear Information System (INIS)

    Lee, T.-H.; Wang, C.-C.; Huang, T.-K.; Chen, L.-K.; Chou, M.-Y.; Huang, H.-H.

    2009-01-01

    This study was to investigate the corrosion resistance of different Ti-containing dental orthodontic wires (including Ni-Ti, Ni-Ti-Cu, Ti-Mo-Zr-Sn, and Ti-Nb alloys) in acidic fluoride-containing artificial saliva using cyclic potentiodynamic polarization curve measurements. Different NaF concentrations (0%, 0.2%, and 0.5%), simulating the fluoride contents in commercial toothpastes, were added to the artificial saliva. Surface characterization was analyzed using X-ray photoelectron spectrometry. Cyclic potentiodynamic polarization curves showed that the presence of fluoride ions, especially 0.5% NaF, was detrimental to the protective ability of the TiO 2 -based film on the Ti-containing wires. This might lead to a decrease in the corrosion resistance of the tested alloys, i.e. an increase in the corrosion rate and anodic current density and a decrease in the passive film breakdown potential. Among the tested Ti-containing wires, the Ni-Ti and Ni-Ti-Cu wires containing mainly TiO 2 on surface film were more susceptible to fluoride-enhanced corrosion, while the Ti-Mo-Zr-Sn and Ti-Nb wires containing MoO 3 /ZrO 2 /SnO and Nb 2 O 5 , respectively, along with TiO 2 on surface film were pitting corrosion resistant and showed a lower susceptibility to fluoride-enhanced corrosion. The difference in corrosion resistance of the tested commercial Ti-containing dental orthodontic wires was significantly dependent on the passive film characteristics on wires' surface.

  13. Applicability of the Rivermead Behavioural Memory Test – Third Edition (RBMT-3) in Korsakoff’s syndrome and chronic alcoholics

    Science.gov (United States)

    Wester, Arie J; van Herten, Judith C; Egger, Jos IM; Kessels, Roy PC

    2013-01-01

    Purpose To examine the applicability of the newly developed Rivermead Behavioural Memory Test – Third Edition (RBMT-3) as an ecologically-valid memory test in patients with alcohol-related cognitive disorders. Patients and methods An authorized Dutch translation of the RBMT-3 was developed, equivalent to the UK version, and administered to a total of 151 participants – 49 patients with amnesia due to alcoholic Korsakoff’s syndrome, 49 patients with cognitive impairment and a history of chronic alcoholism, not fulfilling the Korsakoff criteria, and 53 healthy controls. Between-group comparisons were made at subtest level, and the test’s diagnostic accuracy was determined. Results Korsakoff patients performed worse than controls on all RBMT-3 subtests (all P-values Korsakoff patients and the controls after delayed testing. The RBMT-3 had good sensitivity and adequate specificity. Conclusion The RBMT-3 is a valid test battery to demonstrate everyday memory deficits in Korsakoff patients and non-Korsakoff patients with alcohol abuse disorder. Korsakoff patients showed an impaired performance on subtests relying on orientation, contextual memory and delayed testing. Our findings provide valuable information for treatment planning and adjustment in patients with alcohol-related cognitive impairments. PMID:23818787

  14. A comparison of the effects of added saliva, α-amylase and water on texture perception in semisolids

    NARCIS (Netherlands)

    Engelen, L.; Wijk, R.A. de; Prinz, J.F.; Janssen, A.M.; Bilt, A. van der; Weenen, H.; Bosman, F.

    2003-01-01

    The effect of adding saliva or a saliva-related fluid (α-amylase solution and water) to custard prior to ingestion on the sensory ratings of odour, flavour and lip-tooth-, mouth- and after-feel sensations was investigated. Saliva had previously been collected from the subjects and each subject

  15. The levels of bioelements in the saliva and hair of young athletes

    Directory of Open Access Journals (Sweden)

    N. A. Troegubova

    2016-01-01

    Full Text Available The salivary and hair levels of bioelements, such as calcium, potassium, magnesium, iron, zinc, chromium, and selenium, were investigated in 130 children and adolescents, including 35 swimmers, 47 hockey players, 20 fencers, and 28 schoolchildren who did not additionally go in for sports. Atomic emission spectrometry and inductively coupled plasma mass spectrometry were applied. The aim of our study was to investigate the characteristics of macro- and microelemental composition of the saliva and hair of young athletes. The investigation established that that all young athletes showed the high levels of potassium and selenium in their hair, those of selenium and chromium in the saliva, and a significantly low concentration of potassium in the saliva (p<0,05, reflecting the intensity of mineral exchange during physical exercises. Individual characteristics were found in the content of chemical elements in the test biological substrates in relation to the kind of sports: the salivary levels of calcium and magnesium were reduced and the hair level of iron was increased in fencers (p<0,05; and the field-hockey players had higher zinc values (p<0,05. Comparison of the hair and salivary concentrations of bioelements established that there was a statistically significant relationship for potassium (R=-0,72; p<0,001 and selenium (R=0,44; p=0,004. Non-invasive screening studies of salivary and hair minerals are recommended for the early diagnosis of an imbalance in macro- and microelements in young athletes. There is evidence that young athletes should be identified as a group of patients at risk for an imbalance of macro- and microelements.

  16. Predictive Utility of Brief Alcohol Use Disorders Identification Test (AUDIT) for human immunodeficiency virus antiretroviral medication nonadherence.

    Science.gov (United States)

    Broyles, Lauren Matukaitis; Gordon, Adam J; Sereika, Susan M; Ryan, Christopher M; Erlen, Judith A

    2011-10-01

    Alcohol use negatively affects adherence to antiretroviral therapy (ART), thus human immunodeficiency virus/acquired immunodeficiency syndrome (HIV/AIDS) care providers need accurate, efficient assessments of alcohol use. Using existing data from an efficacy trial of 2 cognitive-behavioral ART adherence interventions, the authors sought to determine if results on 2 common alcohol screening tests (Alcohol Use Disorders Identification Test--Consumption [AUDIT-C] and its binge-related question [AUDIT-3]) predict ART nonadherence. Twenty-seven percent of the sample (n = 308) were positive on the AUDIT-C and 34% were positive on the AUDIT-3. In multivariate analyses, AUDIT-C-positive status predicted ART nonadherence after controlling for race, age, conscientiousness, and self-efficacy (P = .036). Although AUDIT-3-positive status was associated with ART nonadherence in unadjusted analyses, this relationship was not maintained in the final multivariate model. The AUDIT-C shows potential as an indirect screening tool for both at-risk drinking and ART nonadherence, underscoring the relationship between alcohol and chronic disease management.

  17. Assessment of Alcohol-related Memory Deficits: A Comparison between the Rivermead Behavioural Memory Test and the California Verbal Learning Test

    NARCIS (Netherlands)

    Wester, A.J.; Roelofs, R.L.; Egger, J.I.M.; Kessels, R.P.C.

    2014-01-01

    Objectives: Neuropsychological assessment of memory disorders is an important prerequisite in the treatment of patients with alcohol-related cognitive disorders. Although many memory tests are available in clinical practice, a question remains regarding which test is most appropriate for this

  18. Ademanalyse voor justitiële doeleinden. Artikel in Tijdschrift voor Alcohol, Drugs en andere Psychotrope Stoffen, Vol. 6 , No. 1.

    NARCIS (Netherlands)

    Noordzij, P.C.

    1980-01-01

    At present the blood alcohol content of drivers suspected of having a BAC over the legal limit of 0.5% is being measured by chemical test tube en blood test. This article looks into the possibilities to replace these testing methods with other breath testing devices. Requirements are being suggested

  19. Candida Carriage Rate and Growth Characteristics of Saliva in Diabetes Mellitus Patients: A Case‒Control Study

    Directory of Open Access Journals (Sweden)

    Preethi Balan

    2015-12-01

    Full Text Available Background and aims. The aim of this study was to establish a relationship between salivary glucose levels and Candidacarriage rate in type 2 diabetes mellitus patients and assess the growth characteristics and acid production of Candidain glucose-supplemented saliva. Materials and methods. A total of 90 subjects, 30 with controlled type 2 diabetes, 30 with uncontrolled type 2 diabetes and 30 without diabetes (control subjects, aged 30‒60 years, participated in the study. Unstimulated saliva was collected and investigated for glucose levels (GOD-POD method, colony-forming units (CFU of Candida and salivary pH, using Indikrom paper strips. Analysis of statistical significance of salivary glucose and PH levels was carried out using post hoc Tukey HSD test. Correlation of Candida carriage rate with salivary glucose and salivary PH in the study groups and control group was made using Pearson’s correlation. Results. Candida CFUs were significantly higher in diabetic subjects, with a significant and positive correlation with salivary glucose levels. There was a negative correlation between salivary PH levels and Candida carriage rate. Conclusion. Increased salivary glucose was associated with increased prevalence of oral Candida in diabetic subjects. The growth of Candida in saliva was accompanied by a rapid decline in PH, which in turn favored their growth.

  20. A simple high-performance liquid chromatography for the determination of linezolid in human plasma and saliva.

    Science.gov (United States)

    Hara, Shuuji; Uchiyama, Masanobu; Yoshinari, Masami; Matsumoto, Taichi; Jimi, Shiro; Togawa, Atsushi; Takata, Tohru; Takamatsu, Yasushi

    2015-09-01

    Linezolid is an antimicrobial agent for the treatment of multiresistant Gram-positive infections. A practical high-performance liquid chromatography method was developed for the determination of linezolid in human plasma and saliva. Linezolid and an internal standard (o-ethoxybenzamide) were extracted from plasma and saliva with ethyl acetate and analyzed on a Capcell Pak C18 MG column with UV detection at 254 nm. The calibration curve was linear through the range 0.5-50 µg/mL using a 200 μL sample volume. The intra- and interday precisions were all plasma and 5.60% for saliva. The accuracies ranged from 98.8 to 110% for both matrices. The mean recoveries of linezolid were 80.8% for plasma and 79.0% for saliva. This method was used to determine the plasma and saliva concentrations of linezolid in healthy volunteers who were orally administered a 600 mg dose of linezolid. Our liquid-liquid extraction procedure is easy and requires a small volume of plasma or saliva (200 μL). This small volume can be advantageous in clinical pharmacokinetic studies, especially if children participate. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Air-deployable oil spill sampling devices review phase 2 testing. Volume 1

    International Nuclear Information System (INIS)

    Hawke, L.; Dumouchel, A.; Fingas, M.; Brown, C.E.

    2007-01-01

    SAIC Canada tested air deployable oil sampling devices for the Emergencies Science and Technology Division of Environment Canada in order to determine the applicability and status of these devices. The 3 devices tested were: Canada's SABER (sampling autonomous buoy for evidence recovery), the United States' POPEIE (probe for oil pollution evidence in the environment); and, Sweden's SAR Floatation 2000. They were tested for buoyancy properties, drift behaviour and sampler sorbent pickup ratios. The SAR and SABER both had lesser draft and greater freeboard, while the POPEIE had much greater draft than freeboard. All 3 devices could be used for oil sample collection in that their drift characteristics would allow for the SABER and SAR devices to be placed upwind of the slick while the POPEIE device could be placed downwind of an oil spill. The sorbent testing revealed that Sefar sorbent and Spectra sorbent used in the 3 devices had negative pickup ratios for diesel but performance improved as oil viscosity increased. Both sorbents are inert and capable of collecting oil in sufficient volumes for consistent fingerprinting analysis. 10 refs., 8 tabs., 8 figs

  2. A Test Device Module of the Step Motor Driver for HANARO CAR Operation

    Energy Technology Data Exchange (ETDEWEB)

    Im, Yun-Taek; Doo, Seung-Gyu; Shin, Jin-Won; Kim, Ki-Hyun; Choi, Young-San; Lee, Jung-Hee; Kim, Hyung-Kyoo; Lee, Choong-Sung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The brand-new control system is reliable and has advantages compared with the old control system, and the installed system covers all functional operations of old system. Nevertheless, packaged RTP systems do not include a step motor or driver, and it is necessary to develop a proper test device to check the step motor and driver without using the RTP system. In particular, the operation of a CAR (Control Absorber Rod) requires many complicated procedures. Occasionally, it takes significant time to prepare for a field test. In this work, a test device module for a step motor diver is shown to emulate a HANARO CAR operation, and the test device system architecture, operational principle, and experiment results are presented. A commercial 8-bit μ-processor is applied to implement the device. A portable test device for HANARO CAR operation is presented. An 8-bit μ-controller is used to emulate a HANARO CAR operation. The digital interface, as well as the functional operation, of the test device module matches that of the currently used driver. This device can be used to check the functional validity of the step motor and driver.

  3. A versatile magnetic refrigeration test device

    DEFF Research Database (Denmark)

    Bahl, Christian Robert Haffenden; Petersen, Thomas Frank; Pryds, Nini

    2008-01-01

    of the applied magnetic field. An advanced two-dimensional numerical model has previously been implemented in order to help in the optimization of the design of a refrigeration test device. Qualitative agreement between the results from model and the experimental results is demonstrated for each of the four...... different parameter variations mentioned above. (C) 2008 American Institute of Physics....

  4. Use of Saliva Biomarkers to Monitor Efficacy of Vitamin C in Exercise-Induced Oxidative Stress

    Directory of Open Access Journals (Sweden)

    Levi W. Evans

    2017-01-01

    Full Text Available Saliva is easily obtainable for medical research and requires little effort or training for collection. Because saliva contains a variety of biological compounds, including vitamin C, malondialdehyde, amylase, and proteomes, it has been successfully used as a biospecimen for the reflection of health status. A popular topic of discussion in medical research is the potential association between oxidative stress and negative outcomes. Systemic biomarkers that represent oxidative stress can be found in saliva. It is unclear, however, if saliva is an accurate biospecimen as is blood and/or plasma. Exercise can induce oxidative stress, resulting in a trend of antioxidant supplementation to combat its assumed detriments. Vitamin C is a popular antioxidant supplement in the realm of sports and exercise. One potential avenue for evaluating exercise induced oxidative stress is through assessment of biomarkers like vitamin C and malondialdehyde in saliva. At present, limited research has been done in this area. The current state of research involving exercise-induced oxidative stress, salivary biomarkers, and vitamin C supplementation is reviewed in this article.

  5. 75 FR 61820 - Model Specifications for Breath Alcohol Ignition Interlock Devices (BAIIDs)

    Science.gov (United States)

    2010-10-06

    ... technology to alcohol-specific sensors (such as fuel cell technology based on electro-chemical oxidation of alcohol) or other emerging sensor technologies? Or, should NHTSA not specify the sensor technology and... require alcohol- specific technology in the Model Specifications, but that the particular sensor design...

  6. Modulation of host immunity by tick saliva

    Czech Academy of Sciences Publication Activity Database

    Kotál, Jan; Langhansová, H.; Lieskovská, J.; Andersen, J. F.; Francischetti, I.M.B.; Chavakis, T.; Kopecký, J.; Pedra, J. H. F.; Kotsyfakis, Michalis; Chmelař, J.

    2015-01-01

    Roč. 128, OCT 14 2015 (2015), s. 58-68 ISSN 1874-3919 R&D Projects: GA ČR GAP502/12/2409 Institutional support: RVO:60077344 Keywords : Adaptive immunity * Innate immunity * Saliva * Salivary glands * Tick Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.867, year: 2015

  7. INTERFACE DEVICE FOR NONDESTRUCTIVE TESTING OF RESIDUAL SURFACE STRESSES

    Directory of Open Access Journals (Sweden)

    Gennady A. Perepelkin

    2016-01-01

    Full Text Available The paper considers the organization of connection of a personal computer with a device for nondestructive testing of residual surface stresses. The device works is based on the phenomenon of diffraction of ionizing radiation from the crystal lattice near the surface of the crystallites. Proposed software interface to the organization for each type of user: the device developers, administrators, users. Some aspects of the organization of communication microcontroller to a PC via USB-port

  8. Concentration of total protein and degree of acidity (pH of saliva when fasting and after breakfasting

    Directory of Open Access Journals (Sweden)

    Gemella Nur Illahi

    2016-04-01

    Full Text Available Background: While fasting, the mouth does not work to eat and drink so that the salivary glands become less active so saliva production decreased and there was a change in eating timewhich is relation to the mastication process that impact on changes in the degree of acidity (pH Objectives: To determine the concentration of total protein and the degree of acidity (pH of saliva when fasting and after breakfasting. Materials and Methods: The study was observational analytic design with longitudinal (follow up study conducted in the Hj. Halima Dg. Sikati Dental Hospital inKandea in July 2015, the sampling method was purposive sampling. Population was 35 clinical students at the Department of Dental Public Health, Faculty of Dentistry Hasanuddin University with a total sample of 16 students who fit the criteria of the study subjects. To calculate the total protein of saliva concentration using Kyltecautoanalyzerand pH meter to measure the acidity of saliva. Data was analyzed was using SPSS version 17.0 (paired t-test, p <0.05. Results: The mean of total protein (% while fasting by 0135% ± 0.026 and the mean total protein (% after breakfasting at 0.179% ± 0.035, while the average degree of acidity (pH during fasting at 7.26 ± 0:24 and the average degree of acidity (pH after breakfasting at 7.66 ± 0.23 with p-value (0.000. Conclusions: An increase in the total protein concentration and acidity (pH after breakfasting.

  9. BIG - a binary generator for testing digital devices

    International Nuclear Information System (INIS)

    Annuziata, M.; Sechi, G.

    1988-01-01

    This paper presents an unusual approach to the testing of digital devices. In order to test real time systems, we have designed, built, and used a digital generator able to send 2047 quadruples of 12-bit words, with a frequency range of up to 0.7 MHz. (orig.)

  10. An applied test of the social learning theory of deviance to college alcohol use.

    Science.gov (United States)

    DeMartino, Cynthia H; Rice, Ronald E; Saltz, Robert

    2015-04-01

    Several hypotheses about influences on college drinking derived from the social learning theory of deviance were tested and confirmed. The effect of ethnicity on alcohol use was completely mediated by differential association and differential reinforcement, whereas the effect of biological sex on alcohol use was partially mediated. Higher net positive reinforcements to costs for alcohol use predicted increased general use, more underage use, and more frequent binge drinking. Two unexpected finding were the negative relationship between negative expectations and negative experiences, and the substantive difference between nondrinkers and general drinkers compared with illegal or binge drinkers. The discussion considers implications for future campaigns based on Akers's deterrence theory.

  11. Componentes antiinflamatórios na saliva do Lutzomyia longipalpis, vetor da Leishmania chagasi

    Directory of Open Access Journals (Sweden)

    Marta Chagas Monteiro

    2005-06-01

    Full Text Available A inoculação da saliva de vetores na pele do hospedeiro é importante tanto para a alimentação do inseto quanto para a transmissão e estabelecimento de várias infecções. Em leishmaniose, vários estudos demonstram que a saliva dos vetores Lutzomyia e Phlebotomus contém substâncias com atividades imunossupressoras, imunomodulatórias, vasodilatadoras, anti-plaquetárias e anticoagulantes. Os componentes salivares auxiliam a alimentação do inseto através do aumento do fluxo sanguíneo, assim como induzem a imunossupressão no hospedeiro, o que é fundamental para o estabelecimento da infecção por Leishmania. Neste trabalho foi observado que a saliva induz a produção de IL-10, citocina antiinflamatória, não alterando a produção de IFN-g , citocina próinflamatória, no foco da inflamação. Além disso, a saliva potencializa o edema induzido por carragenina.

  12. Fluorescence spectroscopy for throat cancer detection using human saliva

    Science.gov (United States)

    Kumar, Pavan; Singh, Ashutosh; Zaffar, Mohammad; Pradhan, Asima

    2018-02-01

    Throat precancer detection using fluorescence from human saliva is reported here. It may be noted that accessing the throat for investigation is cumbersome and use of saliva as a diagnostic medium may ease the process. The study has been conducted on three groups of patients: oral squamous cell carcinoma (OSCC), dysplasia, and normal (control). An in-house developed compact set-up has been used for fluorescence measurements. The compact system consist of a 375 nm laser diode, collimating lens, long pass filter, fibers, and cuvette holder. Major and minor bands of flavin adenine dinucleotide (FAD) and porphyrin are observed in the spectra. A receiver operating characteristic (ROC) analysis has been used to evaluate the diagnostic performance. Area under the spectra has been chosen for discrimination among the groups and is able to differentiate OSCC to normal, dysplasia to normal, and OSCC to dysplasia with sensitivities 100% (48/48), 92% (32/35), 77% (37/48), and specificities 96% (50/52), 96% (50/52), 89% (31/35) with the accuracy of 98%, 94% and 82% respectively. Sensitivity and specificity, when differentiating OSCC to normal and dysplasia to normal, are significantly large, which indicates that human saliva may be an excellent diagnostic medium for early detection of throat cancer.

  13. Applicability of the Rivermead Behavioural Memory Test – Third Edition (RBMT-3 in Korsakoff's syndrome and chronic alcoholics

    Directory of Open Access Journals (Sweden)

    Wester AJ

    2013-06-01

    Full Text Available Arie J Wester,1 Judith C van Herten,2 Jos IM Egger,2–4 Roy PC Kessels1,2,5 1Korsakoff Clinic, Vincent van Gogh Institute for Psychiatry, Venray, The Netherlands; 2Donders Institute for Brain, Cognition and Behavior, Radboud University Nijmegen, Nijmegen, The Netherlands; 3Centre of Excellence for Neuropsychiatry, Vincent van Gogh Institute for Psychiatry, Venray, The Netherlands; 4Behavioral Science Institute, Radboud University Nijmegen, Nijmegen, The Netherlands; 5Department of Medical Psychology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands Purpose: To examine the applicability of the newly developed Rivermead Behavioural Memory Test – Third Edition (RBMT-3 as an ecologically-valid memory test in patients with alcohol-related cognitive disorders. Patients and methods: An authorized Dutch translation of the RBMT-3 was developed, equivalent to the UK version, and administered to a total of 151 participants – 49 patients with amnesia due to alcoholic Korsakoff's syndrome, 49 patients with cognitive impairment and a history of chronic alcoholism, not fulfilling the Korsakoff criteria, and 53 healthy controls. Between-group comparisons were made at subtest level, and the test's diagnostic accuracy was determined. Results: Korsakoff patients performed worse than controls on all RBMT-3 subtests (all P-values < 0.0005. The alcoholism group performed worse than controls on most (all P-values < 0.02, but not all RBMT-3 subtests. Largest effects were found between the Korsakoff patients and the controls after delayed testing. The RBMT-3 had good sensitivity and adequate specificity. Conclusion: The RBMT-3 is a valid test battery to demonstrate everyday memory deficits in Korsakoff patients and non-Korsakoff patients with alcohol abuse disorder. Korsakoff patients showed an impaired performance on subtests relying on orientation, contextual memory and delayed testing. Our findings provide valuable information for treatment

  14. Device-independent parallel self-testing of two singlets

    Science.gov (United States)

    Wu, Xingyao; Bancal, Jean-Daniel; McKague, Matthew; Scarani, Valerio

    2016-06-01

    Device-independent self-testing offers the possibility of certifying the quantum state and measurements, up to local isometries, using only the statistics observed by querying uncharacterized local devices. In this paper we study parallel self-testing of two maximally entangled pairs of qubits; in particular, the local tensor product structure is not assumed but derived. We prove two criteria that achieve the desired result: a double use of the Clauser-Horne-Shimony-Holt inequality and the 3 ×3 magic square game. This demonstrate that the magic square game can only be perfectly won by measuring a two-singlet state. The tolerance to noise is well within reach of state-of-the-art experiments.

  15. Test plan for K Basin Sludge Canister and Floor Sampling Device

    International Nuclear Information System (INIS)

    Meling, T.A.

    1995-01-01

    This document provides the test plan and procedure forms for conducting the functional and operational acceptance testing of the K Basin Sludge Canister and Floor Sampling Device(s). These samplers samples sludge off the floor of the 100K Basins and out of 100K fuel storage canisters

  16. Study of the elemental composition of saliva of smokers and nonsmokers by X-ray fluorescence

    International Nuclear Information System (INIS)

    Poles, Antônio A.; Balcão, Victor M.; Chaud, Marco V.; Vila, Marta M.D.C.; Aranha, Norberto; Yoshida, Valquíria M.H.; Oliveira, José M.

    2016-01-01

    Cigarette smoking is a serious public health problem. According to data from the World Health Organization, it is estimated that currently more than 1.2 billion people worldwide do tobacco use and that smoking-related diseases are responsible for about 6 million deaths each. With attention to this, it is necessary to seek preventive and prognostic of trying to reduce these numbers and alert the public in general about the danger and the harm caused by its use. Thus, the objective of the research work undertaken was to evaluate and compare the chemical composition of collected saliva samples of smokers and nonsmokers by X-ray Fluorescence analyses. 32 individuals were selected, 16 of which used cigarette on a daily basis and the other 16 had never smoked. Saliva was collected with the help of a (sterile) disposable Pasteur pipette and samples sent to the Applied Nuclear Physics Laboratory at UNISO (LAFINAU), where analyzes were carried out. Individuals who agreed to participate in the study answered a questionnaire to define their profile of inclusion and signed an informed consent form (CEP Protocol no. 831.753 of 09/10/2014). The results clearly showed that there are differences in the concentrations of chemical elements in the saliva of smokers and non-smokers. The biggest discrepancies were found at concentrations of the chemical elements Sulfur, Phosphorus, Chlorine and Potassium, and smaller differences in the concentration of the elements Calcium, Manganese, Iron, Copper, Titanium, Vanadium and Nickel. In only one saliva sample, and in quite low amounts, arsenic was detected. The results indicate that smoking produces more significant changes in the saliva of women than in men, increasing the concentration of some elements in the saliva of female smokers, much more than in the male smokers. The cigarette usage time also appears to exert a greater influence on the composition of the saliva of women than in men, indicating that the damage caused by cigarette

  17. Final report of the safety assessment of Alcohol Denat., including SD Alcohol 3-A, SD Alcohol 30, SD Alcohol 39, SD Alcohol 39-B, SD Alcohol 39-C, SD Alcohol 40, SD Alcohol 40-B, and SD Alcohol 40-C, and the denaturants, Quassin, Brucine Sulfate/Brucine, and Denatonium Benzoate.

    Science.gov (United States)

    2008-01-01

    Alcohol Denat. is the generic term used by the cosmetics industry to describe denatured alcohol. Alcohol Denat. and various specially denatured (SD) alcohols are used as cosmetic ingredients in a wide variety of products. Many denaturants have been previously considered, on an individual basis, as cosmetic ingredients by the Cosmetic Ingredient Review (CIR) Expert Panel, whereas others, including Brucine and Brucine Sulfate, Denatonium Benzoate, and Quassin, have not previously been evaluated. Quassin is a bitter alkaloid obtained from the wood of Quassia amara. Quassin has been used as an insect antifeedant and insecticide and several studies demonstrate its effectiveness. At oral doses up to 1000 mg/kg using rats, Quassin was not toxic in acute and short-term tests, but some reversible piloerection, decrease in motor activity, and a partial loss of righting reflex were found in mice at 500 mg/kg. At 1000 mg/kg given intraperitoneally (i.p.), all mice died within 24 h of receiving treatment. In a cytotoxicity test with brine shrimp, 1 mg/ml of Quassin did not possess any cytotoxic or antiplasmodial activity. Quassin administered to rat Leydig cells in vitro at concentrations of 5-25 ng/ml inhibited both the basal and luteinizing hormone (LH)-stimulated testosterone secretion in a dose-related fashion. Quassin at doses up to 2.0 g/kg in drinking water using rats produced no significant effect on the body weights, but the mean weights of the testes, seminal vesicles, and epididymides were significantly reduced, and the weights of the anterior pituitary glands were significantly increased. The sperm counts and levels of LH, follicle-stimulating hormone (FSH), and testosterone were significantly lower in groups treated with Quassin. Brucine is a derivative of 2-hydroxystrychnine. Swiss-Webster mice given Brucine base, 30 ml/kg, had an acute oral LD(50) of 150 mg/kg, with central nervous system depression followed by convulsions and seizures in some cases. In those

  18. Recent advances in polymer solar cells: realization of high device performance by incorporating water/alcohol-soluble conjugated polymers as electrode buffer layer.

    Science.gov (United States)

    He, Zhicai; Wu, Hongbin; Cao, Yong

    2014-02-01

    This Progress Report highlights recent advances in polymer solar cells with special attention focused on the recent rapid-growing progress in methods that use a thin layer of alcohol/water-soluble conjugated polymers as key component to obtain optimized device performance, but also discusses novel materials and device architectures made by major prestigious institutions in this field. We anticipate that due to drastic improvements in efficiency and easy utilization, this method opens up new opportunities for PSCs from various material systems to improve towards 10% efficiency, and many novel device structures will emerge as suitable architectures for developing the ideal roll-to-roll type processing of polymer-based solar cells. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Investigation of Fe and Ca in non-stimulated human saliva using NAA

    Science.gov (United States)

    de Medeiros, J. A. G.; Zamboni, C. B.; Kovacs, L.; Lewgoy, H. R.

    2015-07-01

    In this study we investigated non-stimulated human whole saliva of healthy subjects and patients with periodontal disease using Neutron Activation Analysis technique (NAA). The measurements were performed in the IEA-R1 nuclear reactor at IPEN-CNEN/SP. We found considerable metabolic changes mainly in Fe and Ca concentration in whole saliva of periodontal patients. These data are useful for identifying or preventing this oral disease in the Brazilian population.

  20. Detection of rabies antigen in the saliva and brains of apparently healthy dogs slaughtered for human consumption and its public health implications in abia state, Nigeria.

    Science.gov (United States)

    Mshelbwala, P P; Ogunkoya, A B; Maikai, B V

    2013-01-01

    The study was carried out in eight dogs slaughtering outlets within four Local Government Areas of the State for the determination of rabies antigen in the saliva and brain of apparently healthy dogs slaughtered for human consumption. A total of one hundred (100) samples each of saliva and brain were collected before and after slaughter, respectively, between April to June, 2013, in the selected areas. The saliva was subjected to rapid immune-chromatographic test (RICT) while direct fluorescent antibody test (DFAT) was carried out on the brain samples. Structured questionnaire was administered to nineteen (19) dog meat processors comprising 18 males and 1 female in the selected areas. Sixty four percent of the samples tested were from female dogs while 36% were from males, 5% tested positive for rabies antigen with the use of both tests; there was no statistical association between sex and rabies status of the dogs sampled (P > 0.05). Butchers bitten during the course of slaughtering were 94.7% out of which 72.8% utilized traditional method of treatment and only 27.8% reported to the hospital for proper medical attention. This study has established the presence of rabies antigen in apparently healthy dogs in the study area.