WorldWideScience

Sample records for salisbury eye evaluation

  1. Older drivers and rapid deceleration events: Salisbury Eye Evaluation Driving Study.

    Science.gov (United States)

    Keay, Lisa; Munoz, Beatriz; Duncan, Donald D; Hahn, Daniel; Baldwin, Kevin; Turano, Kathleen A; Munro, Cynthia A; Bandeen-Roche, Karen; West, Sheila K

    2013-09-01

    Drivers who rapidly change speed while driving may be more at risk for a crash. We sought to determine the relationship of demographic, vision, and cognitive variables with episodes of rapid decelerations during five days of normal driving in a cohort of older drivers. In the Salisbury Eye Evaluation Driving Study, 1425 older drivers aged 67-87 were recruited from the Maryland Motor Vehicle Administration's rolls for licensees in Salisbury, Maryland. Participants had several measures of vision tested: visual acuity, contrast sensitivity, visual fields, and the attentional visual field. Participants were also tested for various domains of cognitive function including executive function, attention, psychomotor speed, and visual search. A custom created driving monitoring system (DMS) was used to capture rapid deceleration events (RDEs), defined as at least 350 milli-g deceleration, during a five day period of monitoring. The rate of RDE per mile driven was modeled using a negative binomial regression model with an offset of the logarithm of the number of miles driven. We found that 30% of older drivers had one or more RDE during a five day period, and of those, about 1/3 had four or more. The rate of RDE per mile driven was highest for those drivers drivingRDE's were more likely to have better scores in cognitive tests of psychomotor speed and visual search, and have faster brake reaction time. Further, greater average speed and maximum speed per driving segment was protective against RDE events. In conclusion, contrary to our hypothesis, older drivers who perform rapid decelerations tend to be more "fit", with better measures of vision and cognition compared to those who do not have events of rapid deceleration. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Visual and cognitive predictors of performance on brake reaction test: Salisbury eye evaluation driving study.

    Science.gov (United States)

    Zhang, Lei; Baldwin, Kevin; Munoz, Beatriz; Munro, Cynthia; Turano, Kathleen; Hassan, Shirin; Lyketsos, Constantine; Bandeen-Roche, Karen; West, Sheila K

    2007-01-01

    Concern for driving safety has prompted research into understanding factors related to performance. Brake reaction speed (BRS), the speed with which persons react to a sudden change in driving conditions, is a measure of performance. Our aim is to determine the visual, cognitive, and physical factors predicting BRS in a population sample of 1425 older drivers. The Maryland Department of Motor Vehicles roster of persons aged 67-87 and residing in Salisbury, MD, was used for recruitment of the study population. Procedures included the following: habitual, binocular visual acuity using ETDRS charts, contrast sensitivity using a Pelli-Robson chart, visual fields assessed with a 81-point screening Humphrey field at a single intensity threshold, and a questionnaire to ascertain medical conditions. Cognitive status was assessed using a standard battery of tests for attention, memory, visuo-spatial, and scanning. BRS was assessed using a computer-driven device that measured separately the initial reaction speed (IRS) (from light change to red until removing foot from accelerator) and physical response speed (PRS) (removing foot from accelerator to full brake depression). Five trial times were averaged, and time was converted to speed. The median brake reaction time varied from 384 to 5688 milliseconds. Age, gender, and cognition predicted total BRS, a non-informative result as there are two distinct parts to the task. Once separated, decrease in IRS was associated with low scores on cognitive factors and missing points on the visual field. A decrease in PRS was associated with having three or more physical complaints related to legs and feet, and poorer vision search. Vision was not related to PRS. We have demonstrated the importance of segregating the speeds for the two tasks involved in brake reaction. Only the IRS depends on vision. Persons in good physical condition may perform poorly on brake reaction tests if their vision or cognition is compromised.

  3. Does walking speed mediate the association between visual impairment and self-report of mobility disability? The Salisbury Eye Evaluation Study.

    Science.gov (United States)

    Swenor, Bonnielin K; Bandeen-Roche, Karen; Muñoz, Beatriz; West, Sheila K

    2014-08-01

    To determine whether performance speeds mediate the association between visual impairment and self-reported mobility disability over an 8-year period. Longitudinal analysis. Salisbury, Maryland. Salisbury Eye Evaluation Study participants aged 65 and older (N=2,520). Visual impairment was defined as best-corrected visual acuity worse than 20/40 in the better-seeing eye or visual field less than 20°. Self-reported mobility disability on three tasks was assessed: walking up stairs, walking down stairs, and walking 150 feet. Performance speed on three similar tasks was measured: walking up steps (steps/s), walking down steps (steps/s), and walking 4 m (m/s). For each year of observation, the odds of reporting mobility disability was significantly greater for participants who were visually impaired (VI) than for those who were not (NVI) (odds ratio (OR) difficulty walking up steps=1.58, 95% confidence interval (CI)=1.32-1.89; OR difficulty walking down steps=1.90, 95% CI=1.59-2.28; OR difficulty walking 150 feet=2.11, 95% CI=1.77-2.51). Once performance speed on a similar mobility task was included in the models, VI participants were no longer more likely to report mobility disability than those who were NVI (OR difficulty walking up steps=0.84, 95% CI=0.65-1.11; OR difficulty walking down steps=0.96, 95% CI=0.74-1.24; OR difficulty walking 150 feet=1.22, 95% CI=0.98-1.50). Slower performance speed in VI individuals largely accounted for the difference in the odds of reporting mobility disability, suggesting that VI older adults walk slower and are therefore more likely to report mobility disability than those who are NVI. Improving mobility performance in older adults with visual impairment may minimize the perception of mobility disability. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  4. John of Salisbury on Aristotelian Science

    DEFF Research Database (Denmark)

    Bloch, David

    The First substantial treatment of John of Salisbury's views on Aristotelian science. Important for our understanding of the reception of Aristotle's works and for the history of theories of science.......The First substantial treatment of John of Salisbury's views on Aristotelian science. Important for our understanding of the reception of Aristotle's works and for the history of theories of science....

  5. Comprehensive eye evaluation algorithm

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Zamora, G.; Vahtel, M.; Soliz, P.; Barriga, S.

    2016-03-01

    In recent years, several research groups have developed automatic algorithms to detect diabetic retinopathy (DR) in individuals with diabetes (DM), using digital retinal images. Studies have indicated that diabetics have 1.5 times the annual risk of developing primary open angle glaucoma (POAG) as do people without DM. Moreover, DM patients have 1.8 times the risk for age-related macular degeneration (AMD). Although numerous investigators are developing automatic DR detection algorithms, there have been few successful efforts to create an automatic algorithm that can detect other ocular diseases, such as POAG and AMD. Consequently, our aim in the current study was to develop a comprehensive eye evaluation algorithm that not only detects DR in retinal images, but also automatically identifies glaucoma suspects and AMD by integrating other personal medical information with the retinal features. The proposed system is fully automatic and provides the likelihood of each of the three eye disease. The system was evaluated in two datasets of 104 and 88 diabetic cases. For each eye, we used two non-mydriatic digital color fundus photographs (macula and optic disc centered) and, when available, information about age, duration of diabetes, cataracts, hypertension, gender, and laboratory data. Our results show that the combination of multimodal features can increase the AUC by up to 5%, 7%, and 8% in the detection of AMD, DR, and glaucoma respectively. Marked improvement was achieved when laboratory results were combined with retinal image features.

  6. AFSC/ABL: Salisbury Sound sponge recovery

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — In 1995, an area of the seafloor near Salisbury Sound was trawled to identify immediate effects on large, erect sponges and sea whips. Video transects were made in...

  7. Studies on Makhana (Euryale ferox Salisbury)

    International Nuclear Information System (INIS)

    Verma, Arvind Kumar; Banerji, B.K.; Chakrabarty, Debasis; Datta, S.K.

    2010-01-01

    Makhana (Euryale ferox Salisbury) grows as an exclusive aquatic cash crop in shallow water bodies in north Bihar and lower Assam regions of India. It has nutritional and medicinal properties and supports cottage industry. It is a monotypic genus and the available genetic variability is limited. An attempt was made to understand the cultural practices, genetic variability among the available germplasm and the biochemical changes during seed germination. It was included in an improvement programme using gamma ray induced mutagenesis. Different morphological parameters were selected to find out its sensitivity to different doses of gamma rays. (author)

  8. Dry Eye Disease following Refractive Surgery: A 12-Month Follow-Up of SMILE versus FS-LASIK in High Myopia

    Science.gov (United States)

    Wang, Bingjie; Chu, Renyuan; Dai, Jinhui; Qu, Xiaomei; Zhou, Hao

    2015-01-01

    Purpose. To compare dry eye disease following SMILE versus FS-LASIK. Design. Prospective, nonrandomised, observational study. Patients. 90 patients undergoing refractive surgery for myopia were included. 47 eyes underwent SMILE and 43 eyes underwent FS-LASIK. Methods. Evaluation of dry eye disease was conducted preoperatively and at 1, 3, 6, and 12 months postoperatively, using the Salisbury Eye Evaluation Questionnaire (SEEQ) and TBUT. Results. TBUT reduced following SMILE at 1 and 3 months (p dry eye disease than FS-LASIK at 6 months postoperatively but demonstrates similar degrees of dry eye disease at 12 months. PMID:26649190

  9. Fifty Years of Water Sensitive Urban Design, Salisbury, South Australia

    Institute of Scientific and Technical Information of China (English)

    John C.Radcliffe; Declan Page; Bruce Naumann; Peter Dillon

    2017-01-01

    Australia has developed extensive policies and guidelines for the management of its water.The City of Salisbury,located within metropolitan Adelaide,South Australia,developed rapidly through urbanisation from the 1970s.Water sensitive urban design principles were adopted to maximise the use of the increased run-off generated by urbanisation and ameliorate flood risk.Managed aquifer recharge was introduced for storing remediated low-salinity stormwater by aquifer storage and recovery (ASR) in a brackish aquifer for subsequent irrigation.This paper outlines how a municipal government has progressively adopted principles of Water Sensitive Urban Design during its development within a framework of evolving national water policies.Salisbury's success with stormwater harvesting led to the formation of a pioneering water business that includes linking projects from nine sites to provide a non-potable supply of 5 × 106 m3 ·year-1.These installations hosted a number of applied research projects addressing well configuration,water quality,reliability and economics and facilitated the evaluation of its system as a potential potable water source.The evaluation showed that while untreated stormwater contained contaminants,subsurface storage and end-use controls were sufficient to make recovered water safe for public open space irrigation,and with chlorination,acceptable for third pipe supplies.Drinking water quality could be achieved by adding microfiltration,disinfection with UV and chlorination.The costs that would need to be expended to achieve drinking water safety standards were found to be considerably less than the cost of establishing dual pipe distribution systems.The full cost of supply was determined to be AUD$1.57 m-3 for non-potable water for public open space irrigation,much cheaper than mains water,AUD $3.45 m-3 at that time.Producing and storing potable water was found to cost AUD$1.96 to $2.24 m-3.

  10. EVALUATION OF DRY EYES IN DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Anshu Sharma

    2017-12-01

    Full Text Available BACKGROUND According to the National Eye Institute, dry eye is a condition in which the eye does not produce tears properly. It can also involve tears not having the right consistency or evaporating too quickly. Tears are necessary to help maintain moisture on the surface of the eye and for clear vision. Diabetes is often associated with several significant ocular conditions such as retinopathy, refractive changes, cataracts, glaucoma and macular oedema. However, one of the most common ocular complications associated with diabetes is dry eye. The aim of the study is to study the prevalence of dry eyes in diabetes mellitus and to evaluate ocular and other risk factors relevant to diabetic dry eyes. MATERIALS AND METHODS A hospital-based cross-sectional clinical study of 100 diabetic patients who presented to the Department of Ophthalmology, Santosh Medical College and Hospital, Ghaziabad, between January 2016 to June 2017 was conducted. Detailed diabetic history was recorded. Assessment of anterior segment via slit-lamp biomicroscopy was done. The examinations for dry eyes included Schirmer's test, tear breakup time, fluorescein and rose Bengal staining. RESULTS Sixty two (62% diabetic patients had dry eye. The prevalence in type I was 3% and prevalence in type II was 59%. Dry eye prevalence was maximum in those above 40 years of age. Symptoms like reduced corneal sensation (44% and meibomitis (20% were major attributable risk factors. Ocular surface damage was predominantly superficial punctate keratitis. Retinopathy was not statistically associated with the prevalence of dry eyes. CONCLUSION Diabetes and dry eye appears to be a common association. Reduction in the modifiable risk factors of dry eye is essential to reduce its prevalence. No significant statistical correlation was found between retinopathy and dry eyes. However, examination for dry eyes should be an integral part of the assessment of diabetic eye disease.

  11. Florence Nightingale and the Salisbury incident.

    Science.gov (United States)

    Palmer, I S

    1976-01-01

    Florence Nightingale's astute handling of mismanagement in Free Gifts Stores during the Crimean War underscored her administrative ability. Miss Nightingale went to Scutari ostensibly to nurse the British soldiers, and while there encountered innumerable instances of administrative and managerial ineffectiveness and difficulties. Among these were the problems in the accountability and deployment of supplies as well as the assignment and supervision of female personnel-an untried situation. The article identifies the misdirected organizational management which occasioned the introduction of women into British war nursing and the voluntary participation of the British citizenry in providing supplies and comfort for the Army. Through analysis of Miss Nightingale's and others' private correspondence, the problems of personnel management and supply distribution are brought into sharp focus. The interplay of policies and principles to which Miss Nightingale subscribed, the human frailty of one of her women, Miss Nightingale's illness, and the confusion and stress which characterized the Crimean War are discussed. The compassion, understanding, and rectitude as well as the human values to which Miss Nightingale subscribed in protecting a woman guilty of a breach of trust and felony and the troublesome slanderous attack to which Miss Nightingale was subjected at the instigation of her foes on the home front provide a background for the presentation of the Salisbury affair as an interesting aspect of historical research into the life of the Victorian heroine.

  12. Magnetorefractive cell on basis of the Salisbury screen

    Energy Technology Data Exchange (ETDEWEB)

    Boriskina, Ju.V. [Faculty of Physics, Moscow State University, Leninski Gory, Moscow 119992 (Russian Federation) and Institute of Theoretical and Applied Electrodynamics, OIVT, RAS, Moscow 125412 (Russian Federation)]. E-mail: j_boriskina@mail.ru; Erokhin, S.G. [Faculty of Physics, Moscow State University, Leninski Gory, Moscow 119992 (Russian Federation); Institute of Theoretical and Applied Electrodynamics, OIVT, RAS, Moscow 125412 (Russian Federation); Vinogradov, A.P. [Institute of Theoretical and Applied Electrodynamics, OIVT, RAS, Moscow 125412 (Russian Federation); Inoue, M. [Toyohashi University of Technology, 1-1, Hibari-Ga-Oka, Tempaku, Toyohashi 441-8580 (Japan); Granovsky, A.B. [Faculty of Physics, Moscow State University, Leninski Gory, Moscow 119992 (Russian Federation)

    2006-05-15

    Recently, it has been shown that the magnetorefractive effect (MRE) can be significantly enhanced if a layer of material exhibiting MRE is placed inside a photonic crystal to form a defect mode. We propose to use for the MRE enhancement the Salisbury screen as a competitive and much more simple scheme. Since MRE is mostly due to a change of light absorption under magnetization the three-layer Salisbury structure optimized for highest possible absorption inside magnetic layer provides MRE at least two orders of magnitude greater than that for single layer and of the same value or even greater than that for 37-layer photonic crystal.

  13. Magnetorefractive cell on basis of the Salisbury screen

    International Nuclear Information System (INIS)

    Boriskina, Ju.V.; Erokhin, S.G.; Vinogradov, A.P.; Inoue, M.; Granovsky, A.B.

    2006-01-01

    Recently, it has been shown that the magnetorefractive effect (MRE) can be significantly enhanced if a layer of material exhibiting MRE is placed inside a photonic crystal to form a defect mode. We propose to use for the MRE enhancement the Salisbury screen as a competitive and much more simple scheme. Since MRE is mostly due to a change of light absorption under magnetization the three-layer Salisbury structure optimized for highest possible absorption inside magnetic layer provides MRE at least two orders of magnitude greater than that for single layer and of the same value or even greater than that for 37-layer photonic crystal

  14. Development of an Actuarial Science Program at Salisbury University

    Science.gov (United States)

    Wainwright, Barbara A.

    2014-01-01

    This paper focuses on the development of an actuarial science track for the mathematics major at Salisbury University (SU). A timeline from the initial investigation into such a program through the proposal and approval processes is shared for those who might be interested in developing a new actuarial program. It is wise to start small and take…

  15. Design and Polarization Characteristics Analysis of Dihedral Based on Salisbury Screen

    Directory of Open Access Journals (Sweden)

    Zhang Ran

    2016-12-01

    Full Text Available Salisbury screens have a number of unique electromagnetic scattering characteristics. When appropriately designed, the Salisbury screen can reach the radar target signature transform. Based on the electromagnetic scattering characteristics of the Salisbury screen, we designed a novel dihedral corner, and theoretically analyzed and simulated its electromagnetic scattering characteristics in this study. The results reveal the monostatic radar cross section curves of the 90°and 60° Salisbury screen dihedral and metal dihedral, respectively. Taking an orthogonal dihedral corner as an example, we obtained the polarization scattering matrixes for different incident degrees. In addition, we investigated the influence of illumination frequency, target gestures, and other key factors on the polarization characteristics of the Salisbury screen dihedral corner. The theoretical and simulation analysis results show that compared with the conventional metal dihedral corner, the Salisbury screen dihedral corner significantly influences the scattering characteristics and will have potential application in electronic warfare.

  16. Evaluation of Occupational Closed Globe Eye Injuries

    Directory of Open Access Journals (Sweden)

    Berna Akova-Budak

    2016-01-01

    Full Text Available Aim: To evaluate closed glob injuries related to occupational accidents of patients who had official occupational accident records. Material and Method: The medical records of patients with ocular injuries who referred to Department of Ophthalmology or emergency of Uludag University, School of Medicine between January 2010 and December 2013 with official occupational accident report were retrospectively reviewed. The patients with closed globe injuries following trauma were included. Age, sex, the injured eye, the cause of the trauma, whether the precautions were taken or not by the patient, the damage due to trauma were recorded. Results: According to the official records, 108 patients referred to our clinic with closed globe injury related to occupational accident. One hundred twenty eyes of 108 patients ( 2 females, 106 males were evaluated. The mean age of the patients was 33±8.6 years. The most frequent cause of injury was foreign bodies on the ocular surface followed by blunt trauma. The mean age of the patients injured with foreign bodies was found to be significantly lower than the patients injured with blunt objects (p=0.039. Thirteen patients reported that they had used preventive equipment. Discussion: It is of utmost importance that the awareness of the workers should be raised and they should be educated about the use of preventive equipment to prevent the occupational eye injuries. The education of particularly the younger patients about the occupational injuries when they begin to work may decrease the rate of occupational accident related eye injuries.

  17. Eye Tracker Accuracy: Quantitative Evaluation of the Invisible Eye Center Location

    OpenAIRE

    Wyder, Stephan; Cattin, Philippe C.

    2017-01-01

    Purpose. We present a new method to evaluate the accuracy of an eye tracker based eye localization system. Measuring the accuracy of an eye tracker's primary intention, the estimated point of gaze, is usually done with volunteers and a set of fixation points used as ground truth. However, verifying the accuracy of the location estimate of a volunteer's eye center in 3D space is not easily possible. This is because the eye center is an intangible point hidden by the iris. Methods. We evaluate ...

  18. Evaluation of the Tobii EyeX Eye tracking controller and Matlab toolkit for research.

    Science.gov (United States)

    Gibaldi, Agostino; Vanegas, Mauricio; Bex, Peter J; Maiello, Guido

    2017-06-01

    The Tobii Eyex Controller is a new low-cost binocular eye tracker marketed for integration in gaming and consumer applications. The manufacturers claim that the system was conceived for natural eye gaze interaction, does not require continuous recalibration, and allows moderate head movements. The Controller is provided with a SDK to foster the development of new eye tracking applications. We review the characteristics of the device for its possible use in scientific research. We develop and evaluate an open source Matlab Toolkit that can be employed to interface with the EyeX device for gaze recording in behavioral experiments. The Toolkit provides calibration procedures tailored to both binocular and monocular experiments, as well as procedures to evaluate other eye tracking devices. The observed performance of the EyeX (i.e. accuracy < 0.6°, precision < 0.25°, latency < 50 ms and sampling frequency ≈55 Hz), is sufficient for some classes of research application. The device can be successfully employed to measure fixation parameters, saccadic, smooth pursuit and vergence eye movements. However, the relatively low sampling rate and moderate precision limit the suitability of the EyeX for monitoring micro-saccadic eye movements or for real-time gaze-contingent stimulus control. For these applications, research grade, high-cost eye tracking technology may still be necessary. Therefore, despite its limitations with respect to high-end devices, the EyeX has the potential to further the dissemination of eye tracking technology to a broad audience, and could be a valuable asset in consumer and gaming applications as well as a subset of basic and clinical research settings.

  19. Study on the millimeter-wave scale absorber based on the Salisbury screen

    Science.gov (United States)

    Yuan, Liming; Dai, Fei; Xu, Yonggang; Zhang, Yuan

    2018-03-01

    In order to solve the problem on the millimeter-wave scale absorber, the Salisbury screen absorber is employed and designed based on the RL. By optimizing parameters including the sheet resistance of the surface resistive layer, the permittivity and the thickness of the grounded dielectric layer, the RL of the Salisbury screen absorber could be identical with that of the theoretical scale absorber. An example is given to verify the effectiveness of the method, where the Salisbury screen absorber is designed by the proposed method and compared with the theoretical scale absorber. Meanwhile, plate models and tri-corner reflector (TCR) models are constructed according to the designed result and their scattering properties are simulated by FEKO. Results reveal that the deviation between the designed Salisbury screen absorber and the theoretical scale absorber falls within the tolerance of radar Cross section (RCS) measurement. The work in this paper has important theoretical and practical significance in electromagnetic measurement of large scale ratio.

  20. Evaluation of treatment for dry eye with 2-hydroxyestradiol using a dry eye rat model.

    Science.gov (United States)

    Higuchi, Akihiro; Oonishi, Erina; Kawakita, Tetsuya; Tsubota, Kazuo

    2016-01-01

    2-hydroxy estradiol (2-OHE2) is a catechol derivative of 17β -Estradiol (E2) and it is synthesized from E2 catalyzed by cytochrome P4501A1. Previous studies reported that 2-OHE2 is a physiologic antioxidant in lipoproteins, liver microsomes, and the brain. Catechol derivatives show an anti-inflammatory effect through the inhibition of prostaglandin endoperoxide synthase (PGS) activity. Corneal erosion caused by dry eye is related to an increase in oxidative stress and inflammation in ocular surface cells. We investigated the therapeutic effects of 2-OHE2 on corneal damage caused by dry eye. Steroidal radical scavenging activity was confirmed through the electron spin resonance (ESR) method. PGS activity was measured using the COX Fluorescent Activity Assay Kit. To evaluate the effect of 2-OHE2 on the treatment for dry eye, 2-OHE2 was applied as an eye drop experiment using dry eye model rats. 2-OHE2 scavenged tyrosyl radical and possibly suppressed oxidative stress in corneal epithelial cells. In addition, 2-OHE2 inhibited PGS activity, and 2-OHE2 is probably a competitive inhibitor of PGS. Corneal PGS activity was upregulated in the dry eye group. Therefore, 2-OHE2 eye drops improved corneal erosion in dry eye model rats. 2-OHE2 is a candidate for the treatment of dry eye through the suppression of inflammation and oxidative stress in the cornea.

  1. Evaluating camouflage design using eye movement data.

    Science.gov (United States)

    Lin, Chiuhsiang Joe; Chang, Chi-Chan; Lee, Yung-Hui

    2014-05-01

    This study investigates the characteristics of eye movements during a camouflaged target search task. Camouflaged targets were randomly presented on two natural landscapes. The performance of each camouflage design was assessed by target detection hit rate, detection time, number of fixations on display, first saccade amplitude to target, number of fixations on target, fixation duration on target, and subjective ratings of search task difficulty. The results showed that the camouflage patterns could significantly affect the eye-movement behavior, especially first saccade amplitude and fixation duration, and the findings could be used to increase the sensitivity of the camouflage assessment. We hypothesized that the assessment could be made with regard to the differences in detectability and discriminability of the camouflage patterns. These could explain less efficient search behavior in eye movements. Overall, data obtained from eye movements can be used to significantly enhance the interpretation of the effects of different camouflage design. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  2. Evaluation of diode endoscopic cyclophotocoagulation in bovine cadaver eyes.

    Science.gov (United States)

    Harrington, Jay T; McMullen, Richard J; Cullen, John M; Gilger, Brian C

    2012-09-01

    To evaluate the anterior chamber approach and energy levels for endoscopic cyclophotocoagulation (ECPC) and assess ECPC-induced tissue damage in phakic eyes of bovine cadavers. 12 bovine cadaver eyes. Angle of reach was measured in 6 eyes following placement of a curved endoscopic probe through multiple corneal incisions. In another 6 eyes, each ocular quadrant underwent ECPC at 1 of 3 energy levels (0.75, 0.90, and 1.05 J) or remained untreated. Visible effects on tissues (whitening and contraction of ciliary processes) were scored (scale of 0 [no effects] to 6 [severe effects]), and severity and extent of histologic damage to the pigmented and nonpigmented ciliary epithelium and fibromuscular stroma were each scored (scale of 0 [no effect] to 3 [severe effect]) and summed for each quadrant. Overall mean scores for 6 quadrants/treatment were calculated. Mean ± SD combined angle of reach was 148 ± 24° (range, 123 ± 23° [ventromedial] to 174 ± 11° [dorsolateral]). At the 0.75-, 0.90-, and 1.05-J levels, mean visible tissue effect scores were 3.12 ± 0.47, 3.86 ± 0.35, and 4.68 ± 0.58, respectively; mean histologic damage scores were 4.79 ± 1.38 (mild damage), 6.82 ± 1.47 (moderate damage), and 9.37 ± 1.42 (severe damage), respectively. Occasional popping noises (venting of vaporized interstitial water) were heard at the 1.05-J level. Multiple incisions were necessary to facilitate 360° ECPC treatment in bovine eyes. For ECPC in vivo, the 0.75- and 0.90-J energy levels had the potential to effectively treat the ciliary epithelium.

  3. Eye tracking to evaluate evidence recognition in crime scene investigations.

    Science.gov (United States)

    Watalingam, Renuka Devi; Richetelli, Nicole; Pelz, Jeff B; Speir, Jacqueline A

    2017-11-01

    Crime scene analysts are the core of criminal investigations; decisions made at the scene greatly affect the speed of analysis and the quality of conclusions, thereby directly impacting the successful resolution of a case. If an examiner fails to recognize the pertinence of an item on scene, the analyst's theory regarding the crime will be limited. Conversely, unselective evidence collection will most likely include irrelevant material, thus increasing a forensic laboratory's backlog and potentially sending the investigation into an unproductive and costly direction. Therefore, it is critical that analysts recognize and properly evaluate forensic evidence that can assess the relative support of differing hypotheses related to event reconstruction. With this in mind, the aim of this study was to determine if quantitative eye tracking data and qualitative reconstruction accuracy could be used to distinguish investigator expertise. In order to assess this, 32 participants were successfully recruited and categorized as experts or trained novices based on their practical experiences and educational backgrounds. Each volunteer then processed a mock crime scene while wearing a mobile eye tracker, wherein visual fixations, durations, search patterns, and reconstruction accuracy were evaluated. The eye tracking data (dwell time and task percentage on areas of interest or AOIs) were compared using Earth Mover's Distance (EMD) and the Needleman-Wunsch (N-W) algorithm, revealing significant group differences for both search duration (EMD), as well as search sequence (N-W). More specifically, experts exhibited greater dissimilarity in search duration, but greater similarity in search sequences than their novice counterparts. In addition to the quantitative visual assessment of examiner variability, each participant's reconstruction skill was assessed using a 22-point binary scoring system, in which significant group differences were detected as a function of total

  4. Which Eye Tracker is Right for Your Research Performance Evaluation of Several Cost Variant Eye Trackers

    Science.gov (United States)

    2016-09-19

    utilized to study a diverse number of topics such as the patterns of fixations and saccades while reading text (e.g., Rayner, 1998), the workload of...of their accessibility to our laboratory and because they represent a diverse set of relative price points, from low (Eye Tribe Tracker, Tobii EyeX...see Figure 1 for the layout of those systems). At both workstations, task stimuli were presented to observers on 48.26 cm Samsung SyncMaster 940Bx

  5. Neuroimaging in the Diagnostic Evaluation of Eye Pain.

    Science.gov (United States)

    Szatmáry, Gabriella

    2016-09-01

    Ocular or eye pain is a frequent complaint encountered not only by eye care providers but neurologists. Isolated eye pain is non-specific and non-localizing; therefore, it poses significant differential diagnostic problems. A wide range of neurologic and ophthalmic disorders may cause pain in, around, or behind the eye. These include ocular and orbital diseases and primary and secondary headaches. In patients presenting with an isolated and chronic eye pain, neuroimaging is usually normal. However, at the beginning of a disease process or in low-grade disease, the eye may appear "quiet," misleading a provider lacking familiarity with underlying disorders and high index of clinical suspicion. Delayed diagnosis of some neuro-ophthalmic causes of eye pain could result in significant neurologic and ophthalmic morbidity, conceivably even mortality. This article reviews some recent advances in imaging of the eye, the orbit, and the brain, as well as research in which neuroimaging has advanced the discovery of the underlying pathophysiology and the complex differential diagnosis of eye pain.

  6. Graves' ophthalmopathy evaluated by infrared eye-movement recordings

    International Nuclear Information System (INIS)

    Feldon, S.E.; Unsoeld, R.

    1982-01-01

    Thirteen patients with varying degrees of Graves' ophthalmopathy were examined using high-resolution infrared oculography to determine peak velocities for horizontal eye movements between 3 degrees and 30 degrees. As severity of the orbital disease increased, peak velocities became substantially lower. Vertical-muscle surgery failed to have any effect on peak velocity of horizontal eye movements. In contrast, orbital decompression caused notable improvement in peak velocity of eye movements. Eye-movement recordings, which provide a measure of extraocular muscle function rather than structure, may provide a safe, sensitive, and accurate method for classifying and following up patients with Graves' ophthalmopathy

  7. MOL-Eye: A New Metric for the Performance Evaluation of a Molecular Signal

    OpenAIRE

    Turan, Meric; Kuran, Mehmet Sukru; Yilmaz, H. Birkan; Chae, Chan-Byoung; Tugcu, Tuna

    2017-01-01

    Inspired by the eye diagram in classical radio frequency (RF) based communications, the MOL-Eye diagram is proposed for the performance evaluation of a molecular signal within the context of molecular communication. Utilizing various features of this diagram, three new metrics for the performance evaluation of a molecular signal, namely the maximum eye height, standard deviation of received molecules, and counting SNR (CSNR) are introduced. The applicability of these performance metrics in th...

  8. Attention to eye contact in the West and East: autonomic responses and evaluative ratings.

    Science.gov (United States)

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential

  9. Attention to eye contact in the West and East: autonomic responses and evaluative ratings.

    Directory of Open Access Journals (Sweden)

    Hironori Akechi

    Full Text Available Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect. Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish and East Asian (Japanese cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting, shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.. The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from

  10. Dry Eye Disease following Refractive Surgery: A 12-Month Follow-Up of SMILE versus FS-LASIK in High Myopia

    Directory of Open Access Journals (Sweden)

    Bingjie Wang

    2015-01-01

    Full Text Available Purpose. To compare dry eye disease following SMILE versus FS-LASIK. Design. Prospective, nonrandomised, observational study. Patients. 90 patients undergoing refractive surgery for myopia were included. 47 eyes underwent SMILE and 43 eyes underwent FS-LASIK. Methods. Evaluation of dry eye disease was conducted preoperatively and at 1, 3, 6, and 12 months postoperatively, using the Salisbury Eye Evaluation Questionnaire (SEEQ and TBUT. Results. TBUT reduced following SMILE at 1 and 3 months (p<0.001 and at 1, 3, and 6 months following FS-LASIK (p<0.001. TBUT was greater following SMILE than FS-LASIK at 3, 6, and 12 months (p<0.001, p<0.001, and p=0.009, resp.. SEEQ scores increased (greater symptoms following SMILE at 1 month (p<0.001 and 3 months (p=0.003 and at 1, 3, and 6 months following FS-LASIK (p<0.001. SMILE produced lower SEEQ scores (fewer symptoms than FS-LASIK at 1, 3, and 6 months (p<0.001. Conclusion. SMILE produces less dry eye disease than FS-LASIK at 6 months postoperatively but demonstrates similar degrees of dry eye disease at 12 months.

  11. Evaluation of a remote webcam-based eye tracker

    DEFF Research Database (Denmark)

    Skovsgaard, Henrik; Agustin, Javier San; Johansen, Sune Alstrup

    2011-01-01

    In this paper we assess the performance of an open-source gaze tracker in a remote (i.e. table-mounted) setup, and compare it with two other commercial eye trackers. An experiment with 5 subjects showed the open-source eye tracker to have a significantly higher level of accuracy than one...

  12. An evaluation of the WindEye wind lidar

    DEFF Research Database (Denmark)

    Dellwik, Ebba; Sjöholm, Mikael; Mann, Jakob

    Prevision of the wind field by remote sensing wind lidars has the potential to improve the performance of wind turbines. The functionality of a WindEye lidar developed by Windar Photonics A/S (Denmark) for the wind energy market was tested in a two months long field experiment. The WindEye sensor...... with a high accuracy during the whole campaign....

  13. Evaluating Eye Drop Instillation Technique and Its Determinants in Glaucoma Patients

    Directory of Open Access Journals (Sweden)

    Xinbo Gao

    2018-01-01

    Full Text Available Aim. To evaluate eye drop instillation technique and to explore its determinants in glaucoma patients. Methods. One hundred and thirteen patients diagnosed with glaucoma and self-administering topical antiglaucoma eye drops for at least 1 month were evaluated. All patients instilled artificial tear solution in one eye as they would do at home. The whole process was evaluated by two study staff. A comprehensive score system associated with eye drop instillation techniques was used to quantify the instillation technique and explore its determinants such as demographic and clinical characteristics. Results. Half of the patients (48.67% finished the administration of eye drop on first attempt.1.7 eye drops were squeezed out on average. 43 patients (37.17% got contact with ocular surface or adnexa. Only 19.7% patients had eye drop instillation techniques being defined as well. 11 patients (9.7% had prior instruction regarding using eye drops, while only 4 patients knew to occlude the tear duct by pressing the dacryocyst area. Older age and worse visual acuity were found to be independent risk factors for worse instillation technique. Conclusions. Eye drop instillation technique in glaucoma patients deserves great attention from eye care practitioners during their lifelong follow-up, especially those aged older and have worse visual acuity.

  14. CT evaluation of optic nerve compression in thyroid eye disease

    International Nuclear Information System (INIS)

    Barrett, L.; Giatt, H.J.; Burde, R.M.; Gado, M.

    1986-01-01

    In thyroid eye disease, visual loss due to optic nerve compression by enlarged muscles near the orbital apex requires prompt surgical decompression and must be differentiated from visual loss due to other mechanisms. Seventy-two high-resolution orbital CT scans of patients with thyroid eye disease were analyzed. From a coronal reconstruction, an easily measured ''apical index'' was determined. Average apical indices for orbits without optic neuropathy (41.0%) and with optic neuropathy (70.2%) were significantly different (P < .001). With the aid of the apical index, CT findings can be used to predict which patients with thyroid eye disease have optic nerve compression

  15. Distributions of Benthic Foraminifera in the Salisbury Embayment before and after the PETM Onset

    Science.gov (United States)

    Range, M. M.; Robinson, M. M.

    2017-12-01

    Abrupt climatic perturbations associated with the onset of the Paleocene-Eocene Thermal Maximum (PETM) caused major disruptions to the shallow shelf ecology along the U.S. Atlantic Coastal Plain. Several studies examine the changes in benthic foraminiferal assemblages across the PETM in neritic sediments in New Jersey, Maryland, and Virginia and describe a hydrological and sedimentological paradigm shift that marks the Paleocene-Eocene boundary. In the Salisbury Embayment, a flexural low between the South Jersey High and the Norfolk Arch, this shift is seen in the transition between the upper Paleocene Aquia Formation and the lower Eocene Marlboro Clay. Here we map the abundance of seven benthic foraminifera species from five sites within the Salisbury Embayment from both the uppermost Aquia Formation and the lowermost Marlboro Clay. In addition to the benthic foraminiferal turnover at the PETM onset, we show a geographic distribution of species that highlights a past latitudinal biogeographic zonation not unlike what is found on the modern shelf in this region. Sites document a change in the abundance of species between the late Paleocene and early Eocene, showing a decrease in biodiversity of benthic species along the U.S. Atlantic Coast. Spatial extent of the different species also changed across the Paleocene-Eocene boundary. On the modern Atlantic shelf, a biogeographic zonation is due to the path of the Gulf Stream marking a boundary between relatively cold sea-surface temperatures to the north and warmer temperatures to the south, guided by the geomorphic expression of the mid-Atlantic coastline. During the Paleocene-Eocene transition, we suspect a similar boundary likely existed between the New Jersey sites and the Maryland and Virginia sites. We speculate that with the addition of more assemblage data, we will be able to partially reconstruct the geomorphic expression of the PETM coastline and/or the path of major coastal ocean currents.

  16. Conjunctival impression cytology versus routine tear function tests for dry eye evaluation in contact lens wearers.

    Science.gov (United States)

    Kumar, Prachi; Bhargava, Rahul; Arora, Yogesh C; Kaushal, Sidharth; Kumar, Manjushri

    2015-01-01

    Prolonged contact lens wear is often accompanied by dryness of the eyes. The aim of this study was to compare conjunctival impression cytology (CIC) and tear film tests such as tear film break up time (TBUT) and Schirmer test for dry eye evaluation in contact lens wearers and measure their correlation with dry eye symptoms. A case control study was done at three referral eye centers. The eyes of 230 contact lens users were compared to 250 eyes of age- and sex-matched controls. Participants were recruited based on their response to a questionnaire of dry eye symptoms, (Dry Eye Scoring System, DESS(©)) and measurements of TBUT, Schirmer test, and CIC was done. A correlation analysis between symptom severity and tear film tests was performed. Pearson's coefficient, R(2) > 0.5 was considered significant. As compared to controls (r (2) = 0.010), Nelson grade correlated significantly with dry eye symptoms (r (2) = 0.765), among cases. However, there was moderate correlation between dry eye symptoms, Schirmer test, and TBUT (r (2) = 0.557 and 0.530, respectively) among cases and a weak correlation among controls (r (2) = 0.130 and 0.054, respectively). The sensitivity of TBUT was 86.4%, specificity was 82.4%, positive likelihood ratio (LR) was 4.50 [95% confidence interval (CI) 3.46-5.85)], and negative LR was 0.09. The sensitivity of the Schirmer test was 48.2%, specificity 88%, LR 2.12 (95% CI 1.48-2.96), and negative LR 0.83. CIC correlates better than Schirmer and TBUT with dry eye symptoms. It may be the most appropriate test for dry-eye evaluation in contact lens wearers.

  17. Fluorophotometry as a diagnostic tool for the evaluation of dry eye disease

    Directory of Open Access Journals (Sweden)

    Fan Vincent C

    2006-05-01

    Full Text Available Abstract Background Dry eye disease is a common debilitating ocular disease. Current diagnostic tests used in dry eye disease are often neither sensitive nor reproducible, making it difficult to accurately diagnose and determine end points for clinical trials, or evaluate the usefulness of different medications in the treatment of dry eye disease. The recently developed fluorophotometer can objectively detect changes in the corneal epithelium by quantitatively measuring its barrier function or permeability. The purpose of the study is to investigate the use of corneal fluorescein penetration measured by the fluorophotometer as a diagnostic tool in the evaluation of dry eye patients. Methods Dry eye patients (16 eyes, who presented with a chief complaint of ocular irritation corresponding with dry eye, low Schirmer's one test ( Results Ten minutes after fluorescein installition, patients with dry eye disease averaged a five-fold increase in corneal tissue fluorescein concentration (mean = 375.26 ± 202.67 ng/ml compared with that of normal subjects (mean = 128.19 ± 85.84 ng/ml. Sixty minutes after dye installation, patients with dry eye disease still revealed higher corneal tissue fluorescein concentration (mean = 112.87 ± 52.83 ng/ml compared with that of controls (mean = 40.64 ± 7.96 ng/ml, averaging a three-fold increase. Conclusion Patients with dry eye disease demonstrated an increased corneal permeability and a slower rate of elimination to topically administered fluorescein when measured by the fluorophotometer. This suggests that fluorophotometry may serve as a valuable quantitative and objective tool for the diagnosis of dry eye disease, and in following patients' response to new treatment modalities. Fluorophotometry may serve as an objective non-invasive tool for end-point analysis in clinical trials of new treatments for dry eye disease.

  18. Primary health eye care: evaluation of the competence of medical ...

    African Journals Online (AJOL)

    2009-10-17

    Oct 17, 2009 ... The ability of fifth-year medical students to perform fundoscopy on ... Keywords: primary health eye care; teaching fundoscopy; essential basic ... treatment is implemented at an early stage in the disease.3-5. Such screening and early treatment can reduce the risk of ... Students with a refractive error were.

  19. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow.

    Science.gov (United States)

    Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T

    2018-01-01

    New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.

  20. Evaluation of Dry Eye and Meibomian Gland Dysfunction in Teenagers with Myopia through Noninvasive Keratograph

    Science.gov (United States)

    Wang, Xiu; Lu, Xiaoxiao; Yang, Jun; Wei, Ruihua; Yang, Liyuan; Zhao, Shaozhen; Wang, Xilian

    2016-01-01

    Purpose. This study aims to evaluate dry eye and ocular surface conditions of myopic teenagers by using questionnaire and clinical examinations. Methods. A total of 496 eyes from 248 myopic teenagers (7–18 years old) were studied. We administered Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp examination, and Keratograph 5M. The patients were divided into 2 groups based on OSDI dry eye standard, and their ocular surfaces and meibomian gland conditions were evaluated. Results. The tear meniscus heights of the dry eye and normal groups were in normal range. Corneal fluorescein scores were significantly higher whereas noninvasive break-up time was dramatically shorter in the dry eye group than in the normal group. All three meibomian gland dysfunction parameters (i.e., meibomian gland orifice scores, meibomian gland secretion scores, and meibomian gland dropout scores) of the dry eye group were significantly higher than those of the normal group (P dry eye in myopic teenagers is 18.95%. Meibomian gland dysfunction plays an important role in dry eye in myopic teenagers. The Keratograph 5M appears to provide an effective noninvasive method for assessing ocular surface situation of myopic teenagers. PMID:26881059

  1. Conjunctival impression cytology evaluation of patients with dry eye disease using scleral contact lenses.

    Science.gov (United States)

    Weber, Sarah La Porta; Hazarbassanov, Rossen Mihaylov; Nasaré, Alex; Gomes, José Álvaro Pereira; Hofling-Lima, Ana Luisa

    2017-06-01

    To evaluate conjunctival impression cytology and HLADR expression changes after wearing scleral contact lenses (ScCLs) for moderate to severe dry eye disease (DED). Prospective interventional case series. Forty-one eyes from 25 patients with moderate to severe DED were evaluated for Esclera ScCL treatment. Best-corrected visual acuity (BCVA) and slit-lamp findings were assessed. Impression cytology specimens were obtained from DED patients at the baseline and after wearing ScCLs for 12 months. The impression cytology specimens were analyzed using morphological results score, and HLA-DR positive cells were detected and quantified. The values were compared to assess the IC changes after wearing ScCLs. Forty-one eyes from 25 patients were fitted with ScCLs to manage DED. The underlying diseases were Stevens-Johnson syndrome (22 eyes), Sjogren's syndrome (11 eyes), graft-versus-host disease (2 eyes), dry eye after keratomileusis (2 eyes) and undifferentiated ocular surface disease (4 eyes). The HE-PAS impression cytology score did not differ significantly before and after wearing ScCLs for 12 months in DED patients (p>0.05). The percentage of eyes expressing the HLA-DR antigen in the temporal conjunctiva after wearing ScCL for 12 months significantly increased in patients with Sjogren's syndrome (11.11% to 66.66%; p=0.0498). In groups with Stevens Johnson syndrome and other ocular surface disorders, we did not observe statistically significant differences (p>0.05). The ScCLs did not change the parameters used to evaluate inflammatory processes, which were measured using conjunctival impression cytology and HLA-DR expression, except in Sjogren syndrome, in which there was an unexpected increase in HLA expression. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. Identifying and assessing strategies for evaluating the impact of mobile eye health units on health outcomes.

    Science.gov (United States)

    Fu, Shiwan; Turner, Angus; Tan, Irene; Muir, Josephine

    2017-12-01

    To identify and assess strategies for evaluating the impact of mobile eye health units on health outcomes. Systematic literature review. Worldwide. Peer-reviewed journal articles that included the use of a mobile eye health unit. Journal articles were included if outcome measures reflected an assessment of the impact of a mobile eye health unit on health outcomes. Six studies were identified with mobile services offering diabetic retinopathy screening (three studies), optometric services (two studies) and orthoptic services (one study). This review identified and assessed strategies in existing literature used to evaluate the impact of mobile eye health units on health outcomes. Studies included in this review used patient outcomes (i.e. disease detection, vision impairment, treatment compliance) and/or service delivery outcomes (i.e. cost per attendance, hospital transport use, inappropriate referrals, time from diabetic retinopathy photography to treatment) to evaluate the impact of mobile eye health units. Limitations include difficulty proving causation of specific outcome measures and the overall shortage of impact evaluation studies. Variation in geographical location, service population and nature of eye care providers limits broad application. © 2017 National Rural Health Alliance Inc.

  3. The relationship between better-eye and integrated visual field mean deviation and visual disability.

    Science.gov (United States)

    Arora, Karun S; Boland, Michael V; Friedman, David S; Jefferys, Joan L; West, Sheila K; Ramulu, Pradeep Y

    2013-12-01

    To determine the extent of difference between better-eye visual field (VF) mean deviation (MD) and integrated VF (IVF) MD among Salisbury Eye Evaluation (SEE) subjects and a larger group of glaucoma clinic subjects and to assess how those measures relate to objective and subjective measures of ability/performance in SEE subjects. Retrospective analysis of population- and clinic-based samples of adults. A total of 490 SEE and 7053 glaucoma clinic subjects with VF loss (MD ≤-3 decibels [dB] in at least 1 eye). Visual field testing was performed in each eye, and IVF MD was calculated. Differences between better-eye and IVF MD were calculated for SEE and clinic-based subjects. In SEE subjects with VF loss, models were constructed to compare the relative impact of better-eye and IVF MD on driving habits, mobility, self-reported vision-related function, and reading speed. Difference between better-eye and IVF MD and relationship of better-eye and IVF MD with performance measures. The median difference between better-eye and IVF MD was 0.41 dB (interquartile range [IQR], -0.21 to 1.04 dB) and 0.72 dB (IQR, 0.04-1.45 dB) for SEE subjects and clinic-based patients with glaucoma, respectively, with differences of ≥ 2 dB between the 2 MDs observed in 9% and 18% of the groups, respectively. Among SEE subjects with VF loss, both MDs demonstrated similar associations with multiple ability and performance metrics as judged by the presence/absence of a statistically significant association between the MD and the metric, the magnitude of observed associations (odds ratios, rate ratios, or regression coefficients associated with 5-dB decrements in MD), and the extent of variability in the metric explained by the model (R(2)). Similar associations of similar magnitude also were noted for the subgroup of subjects with glaucoma and subjects in whom better-eye and IVF MD differed by ≥ 2 dB. The IVF MD rarely differs from better-eye MD, and similar associations between VF loss and

  4. Objective evaluation of improvement in optic neuropathy following radiation therapy for thyroid eye disease

    International Nuclear Information System (INIS)

    Rush, Stephen; Winterkorn, Jacqueline; Zak, Rochelle

    2000-01-01

    Purpose: While the literature supports the use of radiation therapy for thyroid eye disease, it does not sufficiently describe in detail the results of radiation therapy for optic neuropathy associated with thyroid eye disease. The objective of this study is to quantify the changes in parameters of optic neuropathy after orbital irradiation for thyroid eye disease. Methods and Materials: Twelve consecutive patients with optic neuropathy from thyroid eye disease were followed by a single neuro-ophthalmology practice and treated by one radiation oncologist with radiation therapy from 1991 through 1995. All cases were prospectively followed for visual acuity, color vision, mean deviation, and/or foveal sensitivity and afferent pupillary defect. All patients received 2000 cGy in 10 fractions with megavoltage irradiation to the orbits. Results: Ten of 12 patients were evaluated for follow-up (one moved out of this country and one had a stroke, which confounded interpretation of examination results). An analysis was performed retrospectively while treatment and evaluation remained uniform. Five men and five women formed the basis of this study with a median age of 60 years (35-76 years). Nineteen eyes were evaluated for thyroid optic neuropathy. Improvement in optic nerve function occurred in eight of ten patients. Improvement was seen either during radiotherapy or within 2 weeks of completion. No long-term adverse effects were noted. Conclusion: This study objectively demonstrates improvement in optic neuropathy from radiation therapy for thyroid eye disease

  5. A randomized clinical evaluation of the safety of Systane® Lubricant Eye Drops for the relief of dry eye symptoms following LASIK refractive surgery

    Directory of Open Access Journals (Sweden)

    Daniel Durrie

    2008-12-01

    Full Text Available Daniel Durrie, Jason StahlDurrie Vision, Overland Park, Kansas, USAPurpose: To evaluate the safety of Systane® Lubricant Eye Drops in relieving the symptoms of dry eye following laser-assisted in situ keratomileusis (LASIK surgery.Methods: This was a randomized, double-masked, single-center, placebo-controlled, contralateral eye study of 30 patients undergoing LASIK surgery. The mean age of patients was 42.4 ± 10.7 years, and the mean spherical equivalent was −3.29 (range, +1.75 to −7.38. Patients’ right and left eyes were randomized to receive either Systane® or placebo – a preserved, thimerosal-free saline solution – beginning from the day of surgery and ending 30 days following surgery. Outcome measures included tear film break up time (TFBUT, visual acuity, degree of corneal and conjunctival staining, and treatment-related adverse events.Results: Preoperatively, placebo-treated eyes had statistically significantly higher sum corneal staining score than Systane®-treated eyes (p = 0.0464; however, the difference was clinically insignificant (p = 0.27. Two weeks post operatively, the average TFBUT in the Systane®-treated eyes was 1.23 seconds longer than that of the placebo-treated eyes (p = 0.028. All other evaluated variables were comparable between the two treatments. No adverse events were reported in the study.Conclusion: Systane® Lubricant Eye Drops are safe for use following LASIK surgery to relieve the discomfort symptoms of dry eye associated with the procedure.Keywords: Systane®, safety, dry eye, LASIK

  6. Can eye tracking boost usability evaluation of computer games?

    DEFF Research Database (Denmark)

    Johansen, Sune Alstrup; Noergaard, Mie; Soerensen, Janus Rau

    2008-01-01

    Good computer games need to be challenging while at the same time being easy to use. Accordingly, besides struggling with well known challenges for usability work, such as persuasiveness, the computer game industry also faces system-specific challenges, such as identifying methods that can provide...... data on players' attention during a game. This position paper discusses how eye tracking may address three core challenges faced by computer game producer IO Interactive in their on-going work to ensure games that are fun, usable, and challenging. These challenges are: (1) Persuading game designers...... about the relevance of usability results, (2) involving game designers in usability work, and (3) identifying methods that provide new data about user behaviour and experience....

  7. Comparative eye-tracking evaluation of scatterplots and parallel coordinates

    Directory of Open Access Journals (Sweden)

    Rudolf Netzel

    2017-06-01

    Full Text Available We investigate task performance and reading characteristics for scatterplots (Cartesian coordinates and parallel coordinates. In a controlled eye-tracking study, we asked 24 participants to assess the relative distance of points in multidimensional space, depending on the diagram type (parallel coordinates or a horizontal collection of scatterplots, the number of data dimensions (2, 4, 6, or 8, and the relative distance between points (15%, 20%, or 25%. For a given reference point and two target points, we instructed participants to choose the target point that was closer to the reference point in multidimensional space. We present a visual scanning model that describes different strategies to solve this retrieval task for both diagram types, and propose corresponding hypotheses that we test using task completion time, accuracy, and gaze positions as dependent variables. Our results show that scatterplots outperform parallel coordinates significantly in 2 dimensions, however, the task was solved more quickly and more accurately with parallel coordinates in 8 dimensions. The eye-tracking data further shows significant differences between Cartesian and parallel coordinates, as well as between different numbers of dimensions. For parallel coordinates, there is a clear trend toward shorter fixations and longer saccades with increasing number of dimensions. Using an area-of-interest (AOI based approach, we identify different reading strategies for each diagram type: For parallel coordinates, the participants’ gaze frequently jumped back and forth between pairs of axes, while axes were rarely focused on when viewing Cartesian coordinates. We further found that participants’ attention is biased: toward the center of the whole plotfor parallel coordinates and skewed to the center/left side for Cartesian coordinates. We anticipate that these results may support the design of more effective visualizations for multidimensional data.

  8. Evaluation of Approaches to Analyzing Continuous Correlated Eye Data When Sample Size Is Small.

    Science.gov (United States)

    Huang, Jing; Huang, Jiayan; Chen, Yong; Ying, Gui-Shuang

    2018-02-01

    To evaluate the performance of commonly used statistical methods for analyzing continuous correlated eye data when sample size is small. We simulated correlated continuous data from two designs: (1) two eyes of a subject in two comparison groups; (2) two eyes of a subject in the same comparison group, under various sample size (5-50), inter-eye correlation (0-0.75) and effect size (0-0.8). Simulated data were analyzed using paired t-test, two sample t-test, Wald test and score test using the generalized estimating equations (GEE) and F-test using linear mixed effects model (LMM). We compared type I error rates and statistical powers, and demonstrated analysis approaches through analyzing two real datasets. In design 1, paired t-test and LMM perform better than GEE, with nominal type 1 error rate and higher statistical power. In design 2, no test performs uniformly well: two sample t-test (average of two eyes or a random eye) achieves better control of type I error but yields lower statistical power. In both designs, the GEE Wald test inflates type I error rate and GEE score test has lower power. When sample size is small, some commonly used statistical methods do not perform well. Paired t-test and LMM perform best when two eyes of a subject are in two different comparison groups, and t-test using the average of two eyes performs best when the two eyes are in the same comparison group. When selecting the appropriate analysis approach the study design should be considered.

  9. Further Evaluation of a Practitioner Model for Increasing Eye Contact in Children With Autism.

    Science.gov (United States)

    Rapp, John T; Cook, Jennifer L; Nuta, Raluca; Balagot, Carissa; Crouchman, Kayla; Jenkins, Claire; Karim, Sidrah; Watters-Wybrow, Chelsea

    2018-02-01

    Cook et al. recently described a progressive model for teaching children with autism spectrum disorder (ASD) to provide eye contact with an instructor following a name call. The model included the following phases: contingent praise only, contingent edibles plus praise, stimulus prompts plus contingent edibles and praise, contingent video and praise, schedule thinning, generalization assessments, and maintenance evaluations. In the present study, we evaluated the extent to which modifications to the model were needed to train 15 children with ASD to engage in eye contact. Results show that 11 of 15 participants acquired eye contact with the progressive model; however, eight participants required one or more procedural modifications to the model to acquire eye contact. In addition, the four participants who did not acquire eye contact received one or more modifications. Results also show that participants who acquired eye contact with or without modifications continued to display high levels of the behavior during follow-up probes. We discuss directions for future research with and limitations of this progressive model.

  10. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow

    OpenAIRE

    Fogt JS; Jones-Jordan LA; Barr JT

    2018-01-01

    Jennifer S Fogt, Lisa A Jones-Jordan, Joseph T Barr The Ohio State University College of Optometry, Columbus, OH, USA Introduction: New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Materials ...

  11. Dosimetric evaluation of lead and tungsten eye shields in electron beam treatment

    International Nuclear Information System (INIS)

    Shiu, Almon S.; Tung, Samuel S.; Gastorf, Robert J.; Hogstrom, Kenneth R.; Morrison, William H.; Peters, Lester J.

    1996-01-01

    Purpose: The purpose of this study is to report that commercially available eye shields (designed for orthovoltage x-rays) are inadequate to protect the ocular structures from penetrating electrons for electron beam energies equal to or greater than 6 MeV. Therefore, a prototype medium size tungsten eye shield was designed and fabricated. The advantages of the tungsten eye shield over lead are discussed. Methods and Materials: Electron beams (6-9 MeV) are often used to irradiate eyelid tumors to curative doses. Eye shields can be placed under the eyelids to protect the globe. Film and thermoluminescent dosimeters (TLDs) were used within a specially constructed polystyrene eye phantom to determine the effectiveness of various commercially available internal eye shields (designed for orthovoltage x-rays). The same procedures were used to evaluate a prototype medium size tungsten eye shield (2.8 mm thick), which was designed and fabricated for protection of the globe from penetrating electrons for electron beam energy equal to 9 MeV. A mini-TLD was used to measure the dose enhancement due to electrons backscattered off the tungsten eye shield, both with or without a dental acrylic coating that is required to reduce discomfort, permit sterilization of the shield, and reduce the dose contribution from backscattered electrons. Results: Transmission of a 6 MeV electron beam through a 1.7 mm thick lead eye shield was found to be 50% on the surface (cornea) of the phantom and 27% at a depth of 6 mm (lens). The thickness of lead required to stop 6-9 MeV electron beams is impractical. In place of lead, a prototype medium size tungsten eye shield was made. For 6 to 9 MeV electrons, the doses measured on the surface (cornea) and at 6 mm (lens) and 21 mm (retina) depths were all less than 5% of the maximum dose of the open field (4 x 4 cm). Electrons backscattered off a tungsten eye shield without acrylic coating increased the lid dose from 85 to 123% at 6 MeV and 87 to 119% at

  12. The orange-brown patina of Salisbury Cathedral (West Porch) surfaces: evidence of its man-made origin.

    Science.gov (United States)

    Martín-Gil, Jesus; Martín-Gil, Francisco Javier; del Carmen Ramos-Sánchez, Maria; Martín-Ramos, Pablo

    2005-09-01

    In this paper, we attempt to elucidate the composition and origin of the orange patina on the surfaces of the West-Porch of Salisbury Cathedral by comparison to other known patinas: (i) the orange-brown patina on the marble surfaces of the Acropolis in Athens and the Arch of Titus in Rome whose analyses have shown very high amounts of phosphates, and generally amino acids from animal-skin glue or other protein binders; (ii) the phosphated patinas which also contain oxalates, found in 1996 on Catalonian calcareous sandstones and in the calcareous dolomites of the Monastery of Silos, Spain, whose origin is either the application of calcium caseinate, or egg yolk and animal glue; and (iii) the patinas with only oxalates found in some of Verona's monuments (St. Zeno) and Spanish sites as in the Monastery of Guadalupe and Cuenca cathedral, formed either by the mineralization of algal filaments or by biological reactions yielding oxalate from yolk egg (added to stone as part of preservative empirical treatments). In the winter of 2003, the West-Porch of Salisbury Cathedral received conservation works, but the old patina was not entirely removed. This fact has allowed us to collect the samples for its study. The IR spectra were registered with a Golden Gate ATR Mk II system using attenuated total reflectance Fourier transform infrared (ATR/FTIR) spectrometry. Mineral composition was determined by XRD (Philips PW 1710 spectrometer with Cu tube), whereas major and trace elements analyses were performed by XRF (Philips PW1480 PW). Microscopy examination was performed on a Leica M655 microscope. Phosphate, oxalate, calcium and sulphate contents were analysed by usual chemical methods. ATD-FTIR spectra of the Salisbury's patina exhibit peaks at 2361, 2341 and 671 cm(-1) (assigned to phosphates); 3410, 1680, 1620, 1122 and 602 cm(-1) (assigned to sulphates); and 1447/1437 and 876 cm(-1) (attributed to carbonates). The little peaks at 1620 and 798 cm(-1) could be assigned to

  13. Eye-lens bismuth shielding in paediatric head CT: artefact evaluation and reduction

    International Nuclear Information System (INIS)

    Raissaki, Maria; Perisinakis, Kostas; Damilakis, John; Gourtsoyiannis, Nicholas

    2010-01-01

    CT scans of the brain, sinuses and petrous bones performed as the initial imaging test for a variety of indications have the potential to expose the eye-lens, considered among the most radiosensitive human tissues, to a radiation dose. There are several studies in adults discussing the reduction of orbital dose resulting from the use of commercially available bismuth-impregnated latex shields during CT examinations of the head. To evaluate bismuth shielding-induced artefacts and to provide suggestions for optimal eye-lens shielding in paediatric head CT. A bismuth shield was placed over the eyelids of 60 consecutive children undergoing head CT. Images were assessed for the presence and severity of artefacts with regard to eye-shield distance and shield wrinkling. An anthropomorphic paediatric phantom and thermoluminescence dosimeters (TLDs) were used to study the effect of eye lens-to-shield distance on shielding efficiency. Shields were tolerated by 56/60 children. Artefacts were absent in 45% of scans. Artefacts on orbits, not affecting and affecting orbit evaluation were noted in 39% and 14% of scans, respectively. Diagnostically insignificant artefacts on intracranial structures were noted in 1 case (2%) with shield misplacement. Mean eye-lens-to-shield distance was 8.8 mm in scans without artefacts, and 4.3 mm and 2.2 mm in scans with unimportant and diagnostically important artefacts, respectively. Artefacts occurred in 8 out of 9 cases with shield wrinkling. Dose reduction remained unchanged for different shield-to-eye distances. Bismuth shielding-related artefacts occurring in paediatric head CT are frequent, superficial and diagnostically insignificant when brain pathology is assessed. Shields should be placed 1 cm above the eyes when orbital pathology is addressed. Shield wrinkling should be avoided. (orig.)

  14. Evaluating of Tear Meniscus Parameters with Optical Coherent Tomography in Dry-Eye Patients

    Directory of Open Access Journals (Sweden)

    Gülizar Soyugelen Demirok

    2013-08-01

    Full Text Available Purpose: To evaluate the changes in meniscus parameters with optical coherence tomography (OCT after treatment and consider the correlation between the OCT parameters and dry-eye tests. Material and Method: Thirty-two dry-eye patients and 30 healthy individuals were included. Visual acuities, biomicroscopic evaluation, Schirmer-I test, tear-break-up time (T-BUT, and lower-tear meniscus parameters measured with OCT were evaluated. Ocular surface disease index (OSDI was performed. The measurements were repeated on the 10th day and 1st month of the treatment. Lower tear meniscus height (LTMH, depth (LTMD, area (LTMA and α-angle were measured. The tear meniscus parameters of the dry-eye group were compared with the control group before treatment, and the correlation between the dry-eye tests and OCT measurements were evaluated. The change in the results of the dry-eye tests and OCT measurements with treatment were assessed. Results: There was statistically no significant difference between the age and gender of the patients in groups. Before treatment the mean Schirmer-I test, TBUT and OSDI scores were different. The LTMH and LTMA were higher in the control group. In the dry-eye group before treatment, there was a negative correlation between the OSDI score and OCT parameters, however, no meaningful correlation was observed between any other test and OCT parameters. Although there were no change in LTMD and α-angle with treatment, the 1st month values of LTMH and LTMA were significantly higher from the pre-treatment and 10th day values. Discussion: When diagnosing dry-eye, TBUT and OSDI scores were found to be more effective compared to Schirmer-I test for the diagnosis of dry eye. Although not adequate by itself, tear meniscus parameters measured with OCT, LTMH and LTMA, may be helpful for evaluating the efficacy of treatment, and the correlation of these two parameters with the OSDI score may increase the objectivity while questioning the

  15. Primary health eye care: evaluation of the competence of medical ...

    African Journals Online (AJOL)

    Background: To evaluate the skill of fifth-year medical students at the University of Cape Town in the performance of fundoscopy at the end of their ophthalmology rotation. Methods: The design was a prospective cohort study. The study was conducted at Groote Schuur Hospital in Cape Town. The ability of fifth-year medical ...

  16. APPLICATION OF EYE TRACKING FOR MEASUREMENT AND EVALUATION IN HUMAN FACTORS STUDIES IN CONTROL ROOM MODERNIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, C.; Spielman, Z.; LeBlanc, K.; Rice, B.

    2017-05-01

    An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collect and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.

  17. Clinical evaluation of an oil-based lubricant eyedrop in dry eye patients with lipid deficiency

    NARCIS (Netherlands)

    Baudouin, Christophe; Galarreta, David J.; Mrukwa-Kominek, Ewa; Böhringer, Daniel; Maurino, Vincenzo; Guillon, Michel; Rossi, Gemma C. M.; van der Meulen, Ivanka J.; Ogundele, Abayomi; Labetoulle, Marc

    2017-01-01

    Purpose: To evaluate and compare the efficacy of a lipid-based lubricant eyedrop formulation (hydroxypropyl guar/propylene glycol/phospholipid [HPG/PG/PL]) with preservative-free saline for the treatment of dry eye. Methods: This was a prospective, multicenter, randomized, single-masked,

  18. Occult intraocular trauma: evaluation of the eye in an austere environment.

    Science.gov (United States)

    Sweet, Patrick H

    2013-03-01

    Physicians deployed to austere environments often encounter the challenge of needing to make clinical decisions based upon rudimentary history and physical examination. These skills, however, can be difficult for many to rely on, with the many subtleties of examining the eye, when they are normally accustomed to relying on sophisticated modalities to establish diagnosis. This case is a model for evaluating eye trauma in an austere or hostile environment. A 25-year-old male U.S. Marine was fired upon at a Mexican Army checkpoint where he sustained glass shrapnel injuries, the most serious being to his right eye. He was taken from a detention facility to a Mexican hospital, where he was evaluated and given the diagnosis of corneal laceration. Twelve hours later, a U.S. Navy physician arrived to evaluate the patient; he was allowed limited access to the patient. His ophthalmologic examination revealed a closed corneal laceration on the right eye, worse than 20/800 vision, absent red reflex, and obscured funduscopic examination. These findings made it impossible to rule out globe penetration. The patient was released 48 h later to a U.S. Naval Hospital, where intraocular foreign bodies were confirmed by imaging and he was taken to emergency surgery. This case illustrates that even under austere conditions, a focused history and evaluation can reveal the likelihood of occult intraocular foreign body, thereby triaging the patient for emergency surgery. Published by Elsevier Inc.

  19. Evaluation of a community-based participatory farmworker eye health intervention in the "black dirt" region of New York state.

    Science.gov (United States)

    Earle-Richardson, Giulia; Wyckoff, Lynae; Carrasquillo, Marilyn; Scribani, Melissa; Jenkins, Paul; May, John

    2014-09-01

    Eye irritation is a constant hazard for migrant and seasonal farmworkers, but there are few studies of the problem or how to address it. Researchers evaluated the effect of a community-based participatory eye health intervention on farmworker eye symptoms in the Hudson Valley, NY. A randomized pre-post intervention with 2, 4-week follow-up periods was implemented with a sample of 97 farmworkers. Five eye symptoms were measured, along with utilization of protective eyewear and eye drops. Leading baseline eye symptoms were redness (49%), blurred vision (43%), itching (43%), and eye pain (29%). Significant reductions in eye pain (P = 0.009), and non-significant reductions in redness were observed for the intervention group while controls experienced increases in both. The intervention was effective in significantly reducing eye pain, and to a lesser extent, redness. Future eyewear promotion programs should offer a range of eye wear, tailor offerings to local climate and tasks, evaluate eyewear durability, and include eye drops. © 2014 Wiley Periodicals, Inc.

  20. Evaluation of a novel dry eye model induced by oral administration of finasteride.

    Science.gov (United States)

    Li, Kai; Zhang, Chuanwei; Yang, Zichao; Wang, Yuliang; Si, Haipeng

    2017-12-01

    Dry eye is a common eye disease, and suitable animal models are indispensable for investigating the pathogenesis and developing treatments for dry eye. The present study was conducted to develop an androgen deficiency dry eye model induced by finasteride, and to evaluate ocular surface status and inflammatory cytokine gene expression in the lacrimal gland using a cytokine antibody array system. The results revealed that the antiandrogenic drug finasteride induced significant tear deficiency, and the histopathology results revealed significant inflammatory cell infiltration in the lacrimal gland. The cytokine antibody array system identified increased B7‑2 (also known as cluster of differentiation 86), interleukin (IL)‑1β, IL‑4, IL‑6, IL‑10, matrix metalloproteinase‑8, Fas ligand, tumor necrosis factor (TNF)‑α and metalloproteinase inhibitor 1 levels in the lacrimal gland of the dry eye model. These cytokines were validated as candidate markers through the use of western blot analysis and reverse transcription‑quantitative polymerase chain reaction. Both analyses confirmed a significant increase in proinflammatory cytokines, including IL‑1β, IL‑6 and TNF‑α, and anti‑inflammatory cytokines, including IL‑4 and IL‑10. The aforementioned data suggested that inflammation in antiandrogenic models resulted from a balance between inflammatory and anti‑inflammatory responses. Thus, direct finasteride administration may produce an applicable model for dry eye mediated by androgen deficiency. In addition, there may be a correlation between sex, steroid deficiency and the inflammatory response. The findings of the present study have provided useful information for the pathogenesis and diagnosis of dry eye mediated by androgen deficiency.

  1. Issues Affecting Community Attitudes and Intended Behaviours in Stormwater Reuse: A Case Study of Salisbury, South Australia

    Directory of Open Access Journals (Sweden)

    Zhifang Wu

    2012-10-01

    Full Text Available Stormwater has been recognised as one of the additional/alternative sources of water to augment freshwater supply and address the growing needs of humankind. South Australia has been a leader in the development of large-scale urban stormwater harvesting schemes in Australia for nearly 50 years and the Salisbury Local Government Area (LGA, in particular, is at the forefront of urban stormwater management and recycling, not only in the state of South Australia, but worldwide. This is mainly due to its pioneering achievements in stormwater capture and treatment through the managed aquifer recharge (MAR process. However, there are many challenges in implementing water reuse strategies and past studies have identified public health concerns and public acceptance as major challenges. In line with this, our team conducted an internet survey to gauge the attitude and intentions of Salisbury LGA residents to use stormwater treated through the MAR process for non-potable uses. We found that respondents’ emotions and perceptions of health risk, regarding the use of treated stormwater, were closely related to the proximity of the end use to human contact. In terms of quality indicators, colour, odour, and salt levels were all seen as being important. Quality preferences were also closely related to the proximity of the end use to human contact, and reflected the use of water for indoor/outdoor purposes.

  2. Performance evaluation for different sensing surface of BICELLs bio-transducers for dry eye biomarkers

    Science.gov (United States)

    Laguna, M. F.; Holgado, M.; Santamaría, B.; López, A.; Maigler, M.; Lavín, A.; de Vicente, J.; Soria, J.; Suarez, T.; Bardina, C.; Jara, M.; Sanza, F. J.; Casquel, R.; Otón, A.; Riesgo, T.

    2015-03-01

    Biophotonic Sensing Cells (BICELLs) are demonstrated to be an efficient technology for label-free biosensing and in concrete for evaluating dry eye diseases. The main advantage of BICELLs is its capability to be used by dropping directly a tear into the sensing surface without the need of complex microfluidics systems. Among this advantage, compact Point of Care read-out device is employed with the capability of evaluating different types of BICELLs packaged on Biochip-Kits that can be fabricated by using different sensing surfaces material. In this paper, we evaluate the performance of the combination of three sensing surface materials: (3-Glycidyloxypropyl) trimethoxysilane (GPTMS), SU-8 resist and Nitrocellulose (NC) for two different biomarkers relevant for dry eye diseases: PRDX-5 and ANXA-11.

  3. ROLE OF HIGH RESOLUTION ULTRASONOGRAPHY IN THE EVALUATION OF POSTERIOR SEGMENT LESIONS OF THE EYE

    Directory of Open Access Journals (Sweden)

    Rashmi Nagaraju

    2015-01-01

    Full Text Available BACKGRO UND: The superficial location of the eye, its cystic composition, and the advent of high - frequency ultrasound make sonography ideal for imaging the eye. Ultrasonography is a simple, readily available, non - invasive, non - ionizing, highly accurate, real time and cost effective modality . OBJECTIVES: 1 To evaluate the accuracy of high resolution B - mode ultrasonography in the diagnosis of posterior segment lesions of eye as compared to ophthalmoscopic examination particularly in cases of opaque conducting media . 2 To evaluate sonographic appearances of various posterior segment lesions of the eye . MATERIALS AND METHODS: 1 A prospective study was carried out on 62 cases with suspected posterior segment lesions of eye. All patients clinically suspected to have p osterior segment lesions in the presence of opaque conducting media were included in the study. Cases suspected to have isolated anterior segmental and extra ocular lesions were excluded. 2 HRUS was performed with Philips IU22 using high frequency probe ( 5 to 17 MHz utilizing contact method. 3 Sonological diagnosis was made based on sonographic features such as location, morphology, echo pattern, color Doppler characteristics, kinetics of the lesion with eye movements and acoustic characteristics of the lesion. 4 Subsequent clinical, lab investigations, surgical and histopathological examinations were carried out as applicable and final diagnosis was made which was correlated with the sonological diagnosis. Sonological diagnosis was also compared with op hthalmoscopic diagnosis. STATISTICAL ANALYSES: The validities and diagnostic accuracies of high resolution ultrasound and ophthalmoscopic examinations were calculated and compared. RESULTS AND CONCLUSIONS: 1 Ultrasound was the initial imaging modality opt ed in most of the cases as it was readily available, simple and cost effective modality. It establishes the diagnosis in significant number of cases superseding the accuracy

  4. Evaluation of a Web-Based Training in Smoking Cessation Counseling Targeting U.S. Eye-Care Professionals

    Science.gov (United States)

    Asfar, Taghrid; Lee, David J.; Lam, Byron L.; Murchison, Ann P.; Mayro, Eileen L.; Owsley, Cynthia; McGwin, Gerald; Gower, Emily W.; Friedman, David S.; Saaddine, Jinan

    2018-01-01

    Background: Smoking causes blindness-related diseases. Eye-care providers are uniquely positioned to help their patients quit smoking. Aims: Using a pre-/postevaluation design, this study evaluated a web-based training in smoking cessation counseling targeting eye-care providers. Method: The training was developed based on the 3A1R protocol:…

  5. Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

    Science.gov (United States)

    Akondi, Vyas; Pérez-Merino, Pablo; Martinez-Enriquez, Eduardo; Dorronsoro, Carlos; Alejandre, Nicolás; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2017-04-01

    Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.]. Copyright 2017, SLACK Incorporated.

  6. Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopy.

    Science.gov (United States)

    Kaushik, Sushmita; Jain, Rajeev; Pandav, Surinder Singh; Gupta, Amod

    2006-09-01

    To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy. Patients with open and closed angles attending a glaucoma clinic were recruited for the study. Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer's classification. These angles were quantified by ultrasound biomicroscopy (UBM) using the following biometric characteristics: Angle opening distance at 250 micro (AOD 250) and 500 micro (AOD 500) from the scleral spur and trabecular meshwork-ciliary process distance (TCPD). The angles were further segregated as "narrow angles" (Schaffer's Grade 2 or less) and "open angles" (Schaffer's Grade 3 and 4). The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation. One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy (P gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58+/-49 micro, 102+/-84 micro and 653+/-124 respectively, while it was 176+/-47 micro, 291+/-62 micro and 883+/-94 micro in eyes with open angles (P gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.

  7. Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopy

    Directory of Open Access Journals (Sweden)

    Kaushik Sushmita

    2006-01-01

    Full Text Available Purpose: To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy. Materials and Methods: Participants: Patients with open and closed angles attending a glaucoma clinic were recruited for the study. Observation Procedures: Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer′s classification. These angles were quantified by ultrasound biomicroscopy (UBM using the following biometric characteristics: Angle opening distance at 250 µ (AOD 250 and 500 µ (AOD 500 from the scleral spur and trabecular meshwork-ciliary process distance (TCPD. The angles were further segregated as "narrow angles" (Schaffer′s Grade 2 or less and "open angles" (Schaffer′s Grade 3 and 4. Main Outcome Measures: The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation. Results: One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy ( P < 0.001. The Pearson correlation coefficient between all UBM parameters and gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58±49 µ, 102±84 µ and 653±124 respectively, while it was 176±47 µ, 291±62 µ and 883±94 µ in eyes with open angles ( P < 0.001 respectively. Conclusions: The angle width estimated by gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.

  8. Evaluation of Color Settings in Aerial Images with the Use of Eye-Tracking User Study

    Science.gov (United States)

    Mirijovsky, J.; Popelka, S.

    2016-06-01

    The main aim of presented paper is to find the most realistic and preferred color settings for four different types of surfaces on the aerial images. This will be achieved through user study with the use of eye-movement recording. Aerial images taken by the unmanned aerial system were used as stimuli. From each image, squared crop area containing one of the studied types of surfaces (asphalt, concrete, water, soil, and grass) was selected. For each type of surface, the real value of reflectance was found with the use of precise spectroradiometer ASD HandHeld 2 which measures the reflectance. The device was used at the same time as aerial images were captured, so lighting conditions and state of vegetation were equal. The spectral resolution of the ASD device is better than 3.0 nm. For defining the RGB values of selected type of surface, the spectral reflectance values recorded by the device were merged into wider groups. Finally, we get three groups corresponding to RGB color system. Captured images were edited with the graphic editor Photoshop CS6. Contrast, clarity, and brightness were edited for all surface types on images. Finally, we get a set of 12 images of the same area with different color settings. These images were put into the grid and used as stimuli for the eye-tracking experiment. Eye-tracking is one of the methods of usability studies and it is considered as relatively objective. Eye-tracker SMI RED 250 with the sampling frequency 250 Hz was used in the study. As respondents, a group of 24 students of Geoinformatics and Geography was used. Their task was to select which image in the grid has the best color settings. The next task was to select which color settings they prefer. Respondents' answers were evaluated and the most realistic and most preferable color settings were found. The advantage of the eye-tracking evaluation was that also the process of the selection of the answers was analyzed. Areas of Interest were marked around each image in the

  9. Research on Evaluation Model for Secondary Task Driving Safety Based on Driver Eye Movements

    Directory of Open Access Journals (Sweden)

    Lisheng Jin

    2014-01-01

    Full Text Available This study was designed to gain insight into the influence of performing different types of secondary task while driving on driver eye movements and to build a safety evaluation model for secondary task driving. Eighteen young drivers were selected and completed the driving experiment on a driving simulator. Measures of fixations, saccades, and blinks were analyzed. Based on measures which had significant difference between the baseline and secondary tasks driving conditions, the evaluation index system was built. Method of principal component analysis (PCA was applied to analyze evaluation indexes data in order to obtain the coefficient weights of indexes and build the safety evaluation model. Based on evaluation scores, the driving safety was grouped into five levels (very high, high, average, low, and very low using K-means clustering algorithm. Results showed that secondary task driving severely distracts the driver and the evaluation model built in this study could estimate driving safety effectively under different driving conditions.

  10. Histological Evaluation of Radioprotection by Silymarin and Brassica Oleracea Extract on Eye of Albino Rat

    International Nuclear Information System (INIS)

    Naguib, N.I.

    2011-01-01

    The present study was performed to evaluate the effects of two different antioxidant agents (an ethanolic seed extract of cabbage B rassica oleracea a nd silymarin) on irradiated rat eye tissues. Silymarin, known for its potent antioxidant activity, was used as a reference. Rats were divided into 6 groups; group I contained control rats, group II rats received gamma radiation (6 Gy) in three fractionated doses for 3 consecutive days, group III rats received silymarin orally through the experiment , group IV rats received ethanolic extract of brassica seeds orally through the experiment, group V rats received silymarin one week before radiation, during radiation and one week after radiation, and group VI rats received brassica extract one week before radiation, during radiation and one week after radiation . The histological study revealed that ethanolic extract of brassica seeds alleviated the manifestations of radiation injury in the eye tissues as compared with the untreated animals and also with those who received the silymarin.

  11. Novel method for evaluation of eye movements in patients with narcolepsy

    DEFF Research Database (Denmark)

    Christensen, Julie A E; Kempfner, Lykke; Leonthin, Helle L

    2017-01-01

    BACKGROUND: Narcolepsy causes abnormalities in the control of wake-sleep, non-rapid-eye-movement (non-REM) sleep and REM sleep, which includes specific eye movements (EMs). In this study, we aim to evaluate EM characteristics in narcolepsy as compared to controls using an automated detector....... RESULTS: NT1 patients had significantly less EMs during wake, N1, and N2 sleep and more EMs during REM sleep compared to clinical controls, and significantly less EMs during wake and N1 sleep compared to NT2 patients. Furthermore, NT1 patients showed less EMs during NREM sleep in the first sleep cycle....... METHODS: We developed a data-driven method to detect EMs during sleep based on two EOG signals recorded as part of a polysomnography (PSG). The method was optimized using the manually scored hypnograms from 36 control subjects. The detector was applied on a clinical sample with subjects suspected...

  12. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    Science.gov (United States)

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P correction without additional near correction is to be recommended.

  13. Development of criteria for evaluating clinical response in thyroid eye disease using a modified Delphi technique

    DEFF Research Database (Denmark)

    Douglas, Raymond S; Tsirbas, Angelo; Gordon, Mark

    2009-01-01

    OBJECTIVE: To identify components of a provisional clinical response index for thyroid eye disease using a modified Delphi technique. METHODS: The International Thyroid Eye Disease Society conducted a structured, 3-round Delphi exercise establishing consensus for a core set of measures for clinical...... parsed into 11 domains for the Delphi surveys. Eighty-four respondents participated in the Delphi 1 survey, providing 220 unique items. Ninety-two members (100% of the respondents from Delphi 1 plus 8 new participants) responded in Delphi 2 and rated the same 220 items. Sixty-four members (76......% of participants) rated 153 criteria in Delphi 3 (67 criteria were excluded because of redundancy). Criteria with a mean greater than 6 (1 = least appropriate to 9 = most appropriate) were further evaluated by the nominal group technique and provisional core measures were chosen. CONCLUSIONS: Using a Delphi...

  14. Ocular surface evaluation in eyes with chronic glaucoma on long term topical antiglaucoma therapy

    Directory of Open Access Journals (Sweden)

    Manu Saini

    2017-06-01

    Full Text Available AIM: To evaluate ocular surface changes and its correlation with the central corneal subbasal nerve fibre layer in chronic glaucoma patients. METHODS: A prospective comparative study of ocular surface evaluation was performed in 50 eyes of 25 patients using two or more antiglaucoma medications for at least 6mo and 50 eyes of 25 normal subjects without any ocular problems as controls. The study parameters evaluated included visual acuity, intraocular pressure, ocular surface evaluation parameters [fluorescein break-up time (FTBUT, Schirmer’s I test, ocular surface staining scores and ocular surface disease index score (OSDI], central corneal sensation (Cochet Bonnett aesthesiometer, central subbasal nerve fiber layer density (SBNFLD by confocal microscopy. RESULTS: The mean values in the glaucoma cases and control groups respectively were as follows: OSDI score (35.89±16.07/6.02±3.84; P=0.001, Schirmer’s I test score (7.63±2.64 mm/12.86±1.93 mm; P=0.001, FTBUT (9.44±2.76s/11.8±1.88s; P=0.001, corneal (5.7±2.33/ 1.1±0.58; P=0.001 and conjunctival staining score (5.06±1.94/0.84±0.46; P=0.001, corneal sensitivity (4.68±0.44/5.07±0.37; P=0.076, mean subbasal nerve fiber number (3.58±0.99/5.40±1.70; P=0.001, SBNFL length (1101.44±287.56 μm/1963.70±562.56 μm; P=0.001 and density (6883.94±1798.03 μm/mm2/12 273.15±3516.04 μm/mm2; P=0.001. Dry eye severity of level 2 and 3 was seen in 66% of glaucoma group. Corneal (R²=0.86 and conjunctival staining (R²=0.71 and OSDI score (R²=0.67 showed statistically significant negative correlation with central corneal SBNFLD while FTBUT (R²=0.84, corneal sensitivity (R²=0.52 showed positive correlation to central corneal SBNFLD in the long term topical antiglaucoma medication group. CONCLUSION: Ocular surface changes and antiglaucoma therapy induced dry eye is found to be associated with decreased SBNFLD in eyes on long term topical antiglaucoma medications.

  15. Optimization and validation of an existing, surgical and robust dry eye rat model for the evaluation of therapeutic compounds.

    Science.gov (United States)

    Joossen, Cedric; Lanckacker, Ellen; Zakaria, Nadia; Koppen, Carina; Joossens, Jurgen; Cools, Nathalie; De Meester, Ingrid; Lambeir, Anne-Marie; Delputte, Peter; Maes, Louis; Cos, Paul

    2016-05-01

    The aim of this research was to optimize and validate an animal model for dry eye, adopting clinically relevant evaluation parameters. Dry eye was induced in female Wistar rats by surgical removal of the exorbital lacrimal gland. The clinical manifestations of dry eye were evaluated by tear volume measurements, corneal fluorescein staining, cytokine measurements in tear fluid, MMP-9 mRNA expression and CD3(+) cell infiltration in the conjunctiva. The animal model was validated by treatment with Restasis(®) (4 weeks) and commercial dexamethasone eye drops (2 weeks). Removal of the exorbital lacrimal gland resulted in 50% decrease in tear volume and a gradual increase in corneal fluorescein staining. Elevated levels of TNF-α and IL-1α have been registered in tear fluid together with an increase in CD3(+) cells in the palpebral conjunctiva when compared to control animals. Additionally, an increase in MMP-9 mRNA expression was recorded in conjunctival tissue. Reference treatment with Restasis(®) and dexamethasone eye drops had a positive effect on all evaluation parameters, except on tear volume. This rat dry eye model was validated extensively and judged appropriate for the evaluation of novel compounds and therapeutic preparations for dry eye disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. The effect of image sharpness on quantitative eye movement data and on image quality evaluation while viewing natural images

    Science.gov (United States)

    Vuori, Tero; Olkkonen, Maria

    2006-01-01

    The aim of the study is to test both customer image quality rating (subjective image quality) and physical measurement of user behavior (eye movements tracking) to find customer satisfaction differences in imaging technologies. Methodological aim is to find out whether eye movements could be quantitatively used in image quality preference studies. In general, we want to map objective or physically measurable image quality to subjective evaluations and eye movement data. We conducted a series of image quality tests, in which the test subjects evaluated image quality while we recorded their eye movements. Results show that eye movement parameters consistently change according to the instructions given to the user, and according to physical image quality, e.g. saccade duration increased with increasing blur. Results indicate that eye movement tracking could be used to differentiate image quality evaluation strategies that the users have. Results also show that eye movements would help mapping between technological and subjective image quality. Furthermore, these results give some empirical emphasis to top-down perception processes in image quality perception and evaluation by showing differences between perceptual processes in situations when cognitive task varies.

  17. Evaluation of eye shields made of tungsten and aluminum in high-energy electron beams

    International Nuclear Information System (INIS)

    Weaver, Randi D.; Gerbi, Bruce J.; Dusenbery, Kathryn E.

    1998-01-01

    Purpose: To protect the lens and cornea of the eye when treating the eyelid with electrons, we designed a tungsten and aluminum eye shield that protected both the lens and cornea, and also limited the amount of backscatter to the overlying eyelid when using electron beam therapy. Methods and Materials: Custom curved tungsten eye shields, 2 mm and 3 mm thick, were placed on Kodak XV film on 8 cm polystyrene and irradiated to evaluate the transmission through the shields. To simulate the thickness of the eyelid and to hold the micro-TLDs, an aquaplast mold was made to match the curvature of the eye shields. Backscatter was measured by placing the micro-TLDs on the beam entrance side to check the dose to the underside of the eyelid. Measurements were done with no aluminum, 0.5, and 1.0 mm of aluminum on top of the tungsten eye shields. The measurements were repeated with 2- and 3-mm flat pieces of lead to determine both the transmission and the backscatter dose for this material. Results: Tungsten proved to be superior to lead for shielding the underlying structures and for reducing backscatter. At 6 MeV, a 3-mm flat slab of tungsten plus 0.5 mm of aluminum, resulted in .042 Gy under the shield when 1.00 Gy is delivered to d max . At 6 MeV for a 3-mm lead plus 0.5-mm aluminum, .046 Gy was measured beneath the shield, a 9.5% decrease with the tungsten. Backscatter was also decreased from 1.17 to 1.13 Gy, a 4% decrease, when using tungsten plus 0.5 mm of aluminum vs. the same thickness of lead. Measurements using 9 MeV were performed in the same manner. With 3 mm tungsten and 0.5 mm of aluminum, at 3 mm depth the dose was .048 Gy compared to .079 Gy with lead and aluminum (39% decrease). Additionally, the backscatter dose was 3% less using tungsten. Simulating the lens dose 3 mm beyond the shield for the 2-mm and 3-mm custom curved tungsten eye shields plus 0.5 mm of aluminum was .030 and .024 Gy, respectively, using 6 MeV (20% decrease). Using 9-MeV electrons, the dose

  18. Evaluating the risk of eye injuries: intraocular pressure during high speed projectile impacts.

    Science.gov (United States)

    Duma, Stefan M; Bisplinghoff, Jill A; Senge, Danielle M; McNally, Craig; Alphonse, Vanessa D

    2012-01-01

    To evaluate the risk of eye injuries by determining intraocular pressure during high speed projectile impacts. A pneumatic cannon was used to impact eyes with a variety of projectiles at multiple velocities. Intraocular pressure was measured with a small pressure sensor inserted through the optic nerve. A total of 36 tests were performed on 12 porcine eyes with a range of velocities between 6.2 m/s and 66.5 m/s. Projectiles selected for the test series included a 6.35  mm diameter metal ball, a 9.25  mm diameter aluminum rod, and an 11.16  mm diameter aluminum rod. Experiments were designed with velocities in the range of projectile consumer products such as toy guns. A range of intraocular pressures ranged between 2017 mmHg to 26,426 mmHg (39 psi-511 psi). Four of the 36 impacts resulted in globe rupture. Intraocular pressures dramatically above normal physiological pressure were observed for high speed projectile impacts. These pressure data provide critical insight to chronic ocular injuries and long-term complications such as glaucoma and cataracts.

  19. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    Directory of Open Access Journals (Sweden)

    Kazunori Hirasawa

    2017-10-01

    Full Text Available AIM: To evaluate the refractive correction for standard automated perimetry (SAP in eyes with refractive multifocal contact lenses (CL in healthy young participants. METHODS: Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline; multifocal CL corrected for distance (mCL-D; and mCL-D corrected for near vision using a spectacle lens (mCL-N. Primary outcome measures were the foveal threshold, mean deviation (MD, and pattern standard deviation (PSD. RESULTS: The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB CONCLUSION: Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  20. Using optical coherence tomography to evaluate glaucoma implant healing response in rabbit eyes

    Science.gov (United States)

    Gossage, Kirk W.; Tkaczyk, Tomasz S.; Barton, Jennifer K.

    2002-06-01

    Glaucoma is a set of diseases that cause optic nerve damage and visual field loss. The most important risk factor for the development of glaucoma is elevated intraocular pressure. One approach used to alleviate the pressure increase is to surgically install glaucoma implants. Two standard Ahmed and ten experimental ePTFE implants were evaluated in this study in rabbit eyes. The implants were imaged with optical coherence tomography (OCT) at 0, 7, 15, 30, and 90 days after implantation. Histology was collected at days 7, 15, 30, and 90 and compared to the OCT images. Preliminary analysis of images indicates that OCT can visualize the development of fibrous encapsulation of the implant, tissue erosion, fibrin accumulation in the implant tube, and tube position in the anterior chamber. A new OCT handheld probe was developed to facilitate in vivo imaging in rabbit eye studies. The OCT probe consists of a mechanical scaffold designed to allow the imaging fiber to be held in a fixed position with respect to the rabbit eye, with minimal anesthesia. A piezo electric lateral scanning device allows the imaging fiber to be scanned across the tissue so that 2D images may be acquired.

  1. Quantitative evaluation of regional blood flow in pulmonary sarcoidosis with Bull's eye analysis

    International Nuclear Information System (INIS)

    Akaki, Shiro

    1991-01-01

    Lung perfusion scintigraphy was performed in 23 patients with pulmonary sarcoidosis and in 11 normal volunteers. Bull's eye analysis was used to analyze regional pulmonary blood flow quantitatively. First, whole lung perfusion images were divided into three regions by three concentric circles. Then radial axes were projected from the center to define 36 x 10deg sectors. The counts for each sector were calculated and a Bull's eye image was displayed. The counts were compared with the lower limit of normal (mean -2SD), and as the indices of reduction in perfusion, extent score (ES) and severity score (SS) were calculated. ES and SS showed significant reduction in perfusion 16 patients (70%) with sarcoidosis. In stage II sarcoidosis, both ES and SS were significantly higher than in stage I sarcoidosis (p 67 Ga scintigraphy findings. In comparison with clinical data, ES had a positive correlation with serum angiotensin-converting enzyme activity (p + /CD8 + ratio (p<0.05). The Bull's eye analysis was considered useful for the quantitative evaluation of regional pulmonary blood flow in pulmonary sarcoidosis, and it was suggested that the mechanism of reduction in perfusion might result mainly in its alveolitis and angitis. Ventilation abnormality, which may happen prior to reduction in perfusion, may be an important factor of reduction in perfusion. (author)

  2. Evaluation of the Safety and Tolerability of Conjunctival Ring for Posterior Segment of the Eye.

    Science.gov (United States)

    Kinoshita, Satoshi; Ohguchi, Takeshi; Noda, Kousuke; Murata, Miyuki; Yasueda, Shin-Ichi; Obata, Haruka; Matsunaga, Toru; Fukushima, Tsutomu; Kanda, Atsuhiro; Ishida, Susumu

    2017-08-01

    To evaluate the safety and tolerability of conjunctival rings (CRs), a novel device for drug delivery to the posterior segment of the eye. In animal studies, CRs containing 5% dexamethasone sodium phosphate (DSP) or vehicle solution were placed on the right and left eyes of C57BL/6J mice, respectively. Contact lenses (CLs) containing vehicle solution were used as a control. Twenty-four hours after placement of the CRs, corneal fluorescein staining was graded based on the McDonald-Shadduck scoring system, ranging from 0 to 4. In humans, CRs containing vehicle solution were placed on the right eye of healthy volunteers for 9 hours. The corneal curvature, corneal thickness, intraocular pressure, visual acuity, tear production (Schirmer I test), tear film break-up time and fluorescein staining scores of the cornea (scores ranging from 0 to 3) and conjunctiva (scores ranging from 0 to 6) were assessed before and after wearing the CRs. The release characteristics of DSP from CRs were also evaluated. In animal experiments, corneal fluorescein staining scores were 1 or less in all the groups, and there was no significant difference between the CR group and the CL group. In the preclinical safety evaluation of CR for humans, ophthalmic examination revealed that CR caused no significant changes in all the parameters investigated including corneal curvature (p = 0.77), corneal thickness (p = 0.96), intraocular pressure (p = 0.59), visual acuity (p = 0.14), Schirmer I test results (p = 0.76), tear film break-up time (p = 0.68), corneal fluorescein staining scores (p = 0.64), and conjunctival fluorescein staining scores (p = 0.52). The DSP release from CRs occurs within a few hours, which is similar to the drug-release property of medicated CL, as reported previously. The current data showed the safety and tolerability of CR as a drug delivery device for the treatment of posterior segment diseases.

  3. A novel evaluation of two related and two independent algorithms for eye movement classification during reading.

    Science.gov (United States)

    Friedman, Lee; Rigas, Ioannis; Abdulin, Evgeny; Komogortsev, Oleg V

    2018-05-15

    Nystrӧm and Holmqvist have published a method for the classification of eye movements during reading (ONH) (Nyström & Holmqvist, 2010). When we applied this algorithm to our data, the results were not satisfactory, so we modified the algorithm (now the MNH) to better classify our data. The changes included: (1) reducing the amount of signal filtering, (2) excluding a new type of noise, (3) removing several adaptive thresholds and replacing them with fixed thresholds, (4) changing the way that the start and end of each saccade was determined, (5) employing a new algorithm for detecting PSOs, and (6) allowing a fixation period to either begin or end with noise. A new method for the evaluation of classification algorithms is presented. It was designed to provide comprehensive feedback to an algorithm developer, in a time-efficient manner, about the types and numbers of classification errors that an algorithm produces. This evaluation was conducted by three expert raters independently, across 20 randomly chosen recordings, each classified by both algorithms. The MNH made many fewer errors in determining when saccades start and end, and it also detected some fixations and saccades that the ONH did not. The MNH fails to detect very small saccades. We also evaluated two additional algorithms: the EyeLink Parser and a more current, machine-learning-based algorithm. The EyeLink Parser tended to find more saccades that ended too early than did the other methods, and we found numerous problems with the output of the machine-learning-based algorithm.

  4. Ethnomedical survey and safety evaluation of traditional eye medicines used in Misungwi district, Tanzania.

    Science.gov (United States)

    Maregesi, Sheila M; Messo, Charles W; Mathias, Juma

    2017-01-01

    This study aimed at documenting products used as traditional eye medicine (TEM) in Misungwi district, Tanzania, and performing preliminary analysis on safety status. Ethnomedical study was conducted in Misungwi district. Information was sourced by face-to-face interview with traditional healers, traditional medicine vendors, and knowledgeable people guided by a well-structured questionnaire. Safety was evaluated by determining pH using pH meter and mineral analysis using the Delta, Portable X-ray fluorescence equipment, and qualitative chemical tests. A total of 23 TEM products were recorded from botanical (79%) and zoological (21%) sources including animal excreta. Liquid preparation ranked highest among dosage forms. Safety evaluation showed that only one product possessed the pH value of 7.4 as recommended for topical ophthalmic medicines. Fourteen minerals were detected and quantified in three samples; some of these minerals are known for their negative effects to the eyes, of medical interest is strontium used for the management of benign eye tumors. Information providers were unaware of health risks associated with the use of TEM. This study has revealed the common use of TEM in Misungwi district. The majority of the products are from the botanical source. Although literature provides supporting data for the application to some of the recorded TEM, safety evaluation by pH and mineral analysis in this study have indicated possible ophthalmological medical problems that could result from using such products. Extensive scientific studies including animal experiments and identification of bioactive compounds are essential to develop safe TEMs.

  5. Clinical evaluation of low vision and central foveal thickness in highly myopic cataract eyes after phacoemulsification

    Directory of Open Access Journals (Sweden)

    Ji-Li Chen

    2015-07-01

    Full Text Available AIM:To retrospectively evaluate central foveal thickness in highly myopic eyes with best correct visual acuity(BCVAMETHODS: In this retrospective clinical study, we consecutively recruited 70 low highly myopic cataract subjects(70 eyesunderwent Phaco. Postoperative visits were performed at 1wk, 1 and 3mo. Postoperative BCVA were recorded and further divided into 2 groups with BCVARESULTS: The ratio of BCVAPr=-0.716, PCONCLUSION: In this study, BCVA is improved after 3mo follow up. There has significant correlation between postoperative BCVA and central foveal thickness.

  6. Evaluating Fault Management Operations Concepts for Next-Generation Spacecraft: What Eye Movements Tell Us

    Science.gov (United States)

    Hayashi, Miwa; Ravinder, Ujwala; McCann, Robert S.; Beutter, Brent; Spirkovska, Lily

    2009-01-01

    Performance enhancements associated with selected forms of automation were quantified in a recent human-in-the-loop evaluation of two candidate operational concepts for fault management on next-generation spacecraft. The baseline concept, called Elsie, featured a full-suite of "soft" fault management interfaces. However, operators were forced to diagnose malfunctions with minimal assistance from the standalone caution and warning system. The other concept, called Besi, incorporated a more capable C&W system with an automated fault diagnosis capability. Results from analyses of participants' eye movements indicate that the greatest empirical benefit of the automation stemmed from eliminating the need for text processing on cluttered, text-rich displays.

  7. Evaluation of the in vitro ocular toxicity of the fortified antibiotic eye drops prepared at the Hospital Pharmacy Departments

    Directory of Open Access Journals (Sweden)

    Anxo Fernández-Ferreiro

    2016-12-01

    Full Text Available The use of parenteral antibiotic eye drop formulations with non-marketed compositions or concentrations, commonly called fortified antibiotic eye drops, is a common practice in Ophthalmology in the hospital setting. The aim of this study was to evaluate the in vitro ocular toxicity of the main fortified antibiotic eye drops prepared in the Hospital Pharmacy Departments. We have conducted an in vitro experimental study in order to test the toxicity of gentamicin, amikacin, cefazolin, ceftazidime, vancomycin, colistimethate sodium and imipenem-cilastatin eye drops; their cytotoxicity and acute tissue irritation have been evaluated. Cell-based assays were performed on human stromal keratocytes, using a cell-based impedance biosensor system [xCELLigence Real-Time System Cell Analyzer (RTCA], and the Hen’s Egg Test for the ocular irritation tests. All the eye drops, except for vancomycin and imipenem, have shown a cytotoxic effect dependent on concentration and time; higher concentrations and longer exposure times will cause a steeper decline in the population of stromal keratocytes. Vancomycin showed a major initial cytotoxic effect, which was reverted over time; and imipenem appeared as a non-toxic compound for stromal cells. The eye drops with the highest irritating effect on the ocular surface were gentamicin and vancomycin. Those antibiotic eye drops prepared at the Hospital Pharmacy Departments included in this study were considered as compounds potentially cytotoxic for the ocular surface; this toxicity was dependent on the concentration used

  8. Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCE(TM).

    Science.gov (United States)

    Jang, Won-Hee; Jung, Kyoung-Mi; Yang, Hye-Ri; Lee, Miri; Jung, Haeng-Sun; Lee, Su-Hyon; Park, Miyoung; Lim, Kyung-Min

    2015-07-01

    The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCE(TM) which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCE(TM) can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines.

  9. Dry Eye

    Science.gov (United States)

    ... Eye » Facts About Dry Eye Listen Facts About Dry Eye Fact Sheet Blurb The National Eye Institute (NEI) ... and their families search for general information about dry eye. An eye care professional who has examined the ...

  10. Automated grading system for evaluation of ocular redness associated with dry eye

    Directory of Open Access Journals (Sweden)

    Rodriguez JD

    2013-06-01

    Full Text Available John D Rodriguez,1 Patrick R Johnston,1 George W Ousler III,1 Lisa M Smith,1 Mark B Abelson1,21Ora, Inc, Andover, MA, USA; 2Department of Ophthalmology, Harvard Medical School, Boston, MA, USABackground: We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye.Aim: To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used.Methods: Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0–4 (in 0.5 increments dry eye redness (Ora CalibraTM Dry Eye Redness Scale [OCDER] scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as "horizontality". From original photograph, the region of interest (ROI was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red was calculated as a single channel 8-bit image as R − 0.83G − 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC were calculated after regression and standardized regression of the dataset.Results: The agreement (both Pearson's and CCC among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple

  11. Evaluation criterions and establishment of dry eye model of rats induced by BTX-B

    Directory of Open Access Journals (Sweden)

    Hai-Feng Zhu

    2015-09-01

    -B solution, with symptoms of dry eyes such as tear secretions reducing and corneal epithelial injury, which can provide experimental basis and foundation for the research on the pathogenesis and experimental treatment of dry eye. Lacritin protein only expresses in acinar cells of lacrimal gland, and the content of Lacritin protein has a synchronous change with tear secretions and degree of dry eye, which provides a new basis for perfecting the standards on evaluating the degree of dry eye.

  12. Automated grading system for evaluation of ocular redness associated with dry eye.

    Science.gov (United States)

    Rodriguez, John D; Johnston, Patrick R; Ousler, George W; Smith, Lisa M; Abelson, Mark B

    2013-01-01

    We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye. To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used. Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0-4 (in 0.5 increments) dry eye redness (Ora Calibra™ Dry Eye Redness Scale [OCDER]) scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as "horizontality"). From original photograph, the region of interest (ROI) was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red) was calculated as a single channel 8-bit image as R - 0.83G - 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor) was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC) were calculated after regression and standardized regression of the dataset. The agreement (both Pearson's and CCC) among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple regression using both redness and horizontality improved the agreement CCC from 0.66 and 0.69 to 0.76, demonstrating the contribution of vessel geometry to the overall grade. Computer analysis of a given image has 100% repeatability and zero

  13. Evaluation of point-of-care test for elevated tear matrix metalloproteinase 9 in post-LASIK dry eyes.

    Science.gov (United States)

    Chan, Tommy C Y; Ye, Cong; Chan, Kwok Ping; Chu, Kai On; Jhanji, Vishal

    2016-09-01

    To evaluate the performance of a point-of-care test for detection of matrix metalloproteinase 9 (MMP-9) levels in post-laser-assisted in situ keratomileusis (LASIK) dry eyes. A comparative study between patients with mild to moderate post-LASIK dry eyes and age-matched normal subjects was conducted. Ocular surface disease index (OSDI), tear break-up time (TBUT), and tear film MMP-9 and total protein levels were compared between the two groups. A point-of-care test device (RPS InflammaDry, Sarasota, Florida, USA) was utilised to confirm elevated MMP-9 levels in tear film. Fourteen post-LASIK dry eyes and 34 normal eyes were included. There was no significant difference in age and gender between both groups (p>0.175). The OSDI was significantly higher (25.5±7.7 vs 7.4±2.5; pdry eye compared with normal subjects. The tear film MMP-9 levels were 52.7±32.5 ng/mL in dry eyes and 4.1±2.1 ng/mL in normal eyes (p40 ng/mL in 7/14 (50.0%) post-LASIK dry eyes. The InflammaDry was positive in 8/14 (57.1%) post-LASIK eyes. All positive cases had tear film MMP-9 levels ≥38.03 ng/mL. Agreement between InflammaDry and MMP-9 was excellent with Cohen κ value of 0.857 in post-LASIK dry eyes. Only half of post-LASIK dry eyes were found to have significant inflammation associated with elevated MMP-9. The OSDI is useful to non-specifically identify patients with symptomatic dry eye while the InflammaDry determined which patients with dry eye were associated with significant inflammation that may guide therapeutic management decisions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. A rating scale is a proper method to evaluate changes in quality of life due to dry eye symptoms.

    Science.gov (United States)

    Xue, Wenwen; Xu, Xian; Zou, Haidong

    2018-02-07

    To determine which utility value assessment method is more suitable to evaluate changes in the quality of life due to dry eye symptoms. Dry eye outpatients with a presenting visual acuity of 20/25 or better in the worse-seeing eye were recruited. Presenting distance visual acuity, tear film break-up time, Schirmer I test and fluorescein were assessed. The severity of dry eye symptoms was assessed using the Ocular Surface Disease Index (OSDI), and utility values were measured using the time trade-off (TTO), standard gamble (SG1 and SG2) and rating scale (RS) methods. Different utility values were compared with each other. The most appropriate utility value method to evaluate quality-of-life changes solely due to dry eye symptoms is determined by calculating the correlation between the OSDI score and different utility values. A total of 104 patients were enrolled. The three sections of OSDI in the order of high to low scores were as follows: "environmental trigger," "eye discomfort" and "visual function." The utility scores measured with TTO, SG1, SG2 and RS were 0.95 ± 0.11, 0.96 ± 0.10, 0.99 ± 0.07 and 0.89 ± 0.10, respectively. The utility scores evaluated by the TTO, SG1, SG2 and RS methods were significantly different from each other (p eye discomfort" section scores (p dry eye symptoms.

  15. In vivo Confocal Microscopy Evaluation of Meibomian Gland Dysfunction in Dry Eye Patients with Different Symptoms

    Directory of Open Access Journals (Sweden)

    Hui Zhao

    2016-01-01

    Conclusions: IVCM application provides a strong support to differentiate dry eye patients with different symptoms: meibomian gland dysfunction (MGD plays a pivotal role in dry eye aggravation, and using IVCM to observe MG fibrosis, changes in size and density of MG as well as status of inflammation cells can help not only correctly diagnose the type and severity of dry eye, but also possibly prognosticate in routine eye examination in the occurrence of MGD.

  16. Evaluating a Tablet Application and Differential Reinforcement to Increase Eye Contact in Children with Autism

    Science.gov (United States)

    Jeffries, Tricia; Crosland, Kimberly; Miltenberger, Raymond

    2016-01-01

    We tested the effectiveness of a tablet application and differential reinforcement to increase eye contact in 3 children with autism. The application required the child to look at a picture of a person's face and identify the number displayed in the person's eyes. Eye contact was assessed immediately after training, 1 hr after training, and in a…

  17. [Evaluation of the arterial blood flow parameters in the eye of myopic patients].

    Science.gov (United States)

    Mrugacz, Małgorzata; Bryl, Anna

    2013-04-01

    Myopia is a common refractive defect. Has a good vision from near and deterioration of vision with increasing distance. The main reason for its occurrence is too long axis of the eyeball. The consequence of elongation of the eyeball is the development of degenerative changes in the retina. Despite much research has failed to clearly identify the causes of degenerative changes in those short-sighted. The aim of the study was to evaluate the maximum and minimum speed in arterial blood vessels of the eye in people with myopia. The study included 70 patients (138 eyes), 53 women and 17 men, aged from 18 to 79 years, with myopia of -0.25 to -18.0 Dsph and length of the eyeball from 22.61 to 33.36 mm. Depending on the kind and the degree of the progress of degenerative changes, patients were divided in 4 groups: I - without degenerative changes on the fundus (n=32; K-23, M-9); II- with the short-sighted sickle (n=20; K-14, M-6); Ill - with the structure thinned down of the retina, accompanying the short-sighted sickle (n = 8; K-6, M-2); IV - with extensive choroidal-retina disappearances in the fundus (n = 10; K-7, M-3). In all individuals enrolled underwent Color Doppler ultrasound with apparatus SSA 770A Toshiba Aplio with linear probe frequency 12 MHz, judging maximum (Vmax) and minimum (Vmin) speed in the arteries of the eye: ophthalmic artery (OA), central retinal artery (CRA) and short posterior ciliary arteries (SPCA) located on the nasal and temporal side of the optic disc. The results were statistically analyzed. No statistically significant relationship between the nature of degenerative changes of the eye, and blood velocity in the OA. There was a increase in Vmax and Vmin blood in OA in Group IV, but these changes were not statistically significant. Statistically significant correlation was observed while in the CRA. With a decrease in Vmax and Vmin of blood flowing through a vessel exacerbation of retinal degeneration. Vmax and Vmin changes in the blood did

  18. Shallow marine response to global climate change during the Paleocene-Eocene Thermal Maximum, Salisbury Embayment, USA

    Science.gov (United States)

    Self-Trail, Jean; Robinson, Marci M.; Bralower, Timothy J.; Sessa, Jocelyn A.; Hajek, Elizabeth A.; Kump, Lee R.; Trampush, Sheila M.; Willard, Debra A.; Edwards, Lucy E.; Powars, David S.; Wandless, Gregory A.

    2017-01-01

    The Paleocene-Eocene Thermal Maximum (PETM) was an interval of extreme warmth that caused disruption of marine and terrestrial ecosystems on a global scale. Here we examine the sediments, flora, and fauna from an expanded section at Mattawoman Creek-Billingsley Road (MCBR) in Maryland and explore the impact of warming at a nearshore shallow marine (30–100 m water depth) site in the Salisbury Embayment. Observations indicate that at the onset of the PETM, the site abruptly shifted from an open marine to prodelta setting with increased terrestrial and fresh water input. Changes in microfossil biota suggest stratification of the water column and low-oxygen bottom water conditions in the earliest Eocene. Formation of authigenic carbonate through microbial diagenesis produced an unusually large bulk carbon isotope shift, while the magnitude of the corresponding signal from benthic foraminifera is similar to that at other marine sites. This proves that the landward increase in the magnitude of the carbon isotope excursion measured in bulk sediment is not due to a near instantaneous release of 12C-enriched CO2. We conclude that the MCBR site records nearshore marine response to global climate change that can be used as an analog for modern coastal response to global warming.

  19. Shallow marine response to global climate change during the Paleocene-Eocene Thermal Maximum, Salisbury Embayment, USA

    Science.gov (United States)

    Self-Trail, Jean M.; Robinson, Marci M.; Bralower, Timothy J.; Sessa, Jocelyn A.; Hajek, Elizabeth A.; Kump, Lee R.; Trampush, Sheila M.; Willard, Debra A.; Edwards, Lucy E.; Powars, David S.; Wandless, Gregory A.

    2017-07-01

    The Paleocene-Eocene Thermal Maximum (PETM) was an interval of extreme warmth that caused disruption of marine and terrestrial ecosystems on a global scale. Here we examine the sediments, flora, and fauna from an expanded section at Mattawoman Creek-Billingsley Road (MCBR) in Maryland and explore the impact of warming at a nearshore shallow marine (30-100 m water depth) site in the Salisbury Embayment. Observations indicate that at the onset of the PETM, the site abruptly shifted from an open marine to prodelta setting with increased terrestrial and fresh water input. Changes in microfossil biota suggest stratification of the water column and low-oxygen bottom water conditions in the earliest Eocene. Formation of authigenic carbonate through microbial diagenesis produced an unusually large bulk carbon isotope shift, while the magnitude of the corresponding signal from benthic foraminifera is similar to that at other marine sites. This proves that the landward increase in the magnitude of the carbon isotope excursion measured in bulk sediment is not due to a near instantaneous release of 12C-enriched CO2. We conclude that the MCBR site records nearshore marine response to global climate change that can be used as an analog for modern coastal response to global warming.

  20. Paleocene to Middle Miocene planktic foraminifera of the southwestern Salisbury Embayment, Virginia and Maryland: biostratigraphy, allostratigraphy, and sequence stratigraphy

    Science.gov (United States)

    Poag, C.W.; Commeau, J.A.

    1995-01-01

    The Paleocene to Middle Miocene sedimentary fill of the southwestern Salisbury Embayment contains a fragmental depositional record, interrupted by numerous local diastems and regional unconformities. Using planktic foraminiferal biostratigraphy, 15 unconformity-bounded depositional units have been identified, assigned to six formations and seven alloformations previously recognized in the embayment. The units correlate with second- and third-order sequences of the Exxon sequence stratigraphy model, and include transgressive and highstand systems tracts. Alloformation, formation, and sequence boundaries are marked by abrupt, scoured, burrowed, erosional surfaces, which display lag deposits, biostratigraphic gaps, and intense reworking of microfossils above and below the boundaries.Paleocene deposits represent the upper parts of upper Pleocene Biochronozones P4 and P5, and rest uncomformably  on Cretaceous sedimentary beds of various ages (Maastrichtian to Albian). Lower Eocene deposits represent parts of Biochronozones P6 and P9. Middle Eocene strata represent mainly parts of Biochronozones P11, P12, and P14. Upper Eocene sediments include parts of Biochronozones P15, P16, and P17. Oligocene deposits encompass parts of Biochronozones. N4b to N7 undifferentiated, P21a, and, perhaps, N4a. Lower Miocene deposits encompass parts of Biochronozones N4b to N7 undifferentiated. Middle Miocene strata represent mainly parts of Biochronorones N8, N9, and N10.Nine plates of scanning electron micrographs illustrate the principal planktic foraminifera used to establish the biostratigraphic framework. Two new informal formine of Praeterenuitella praegemma Li, 1987, are introduced.

  1. Development of an evaluation function for eye-hand coordination robotic therapy.

    Science.gov (United States)

    Pernalete, N; Tang, F; Chang, S M; Cheng, F Y; Vetter, P; Stegemann, M; Grantner, J

    2011-01-01

    This paper is the continuation of a work presented at ICORR 07, in which we discussed the possibility of improving eye-hand coordination in children diagnosed with this problem, using a robotic mapping from a haptic user interface to a virtual environment. Our goal is to develop, implement and refine a system that will assess and improve the eye-hand coordination and grip strength in children diagnosed with poor graphomotor skills. A detailed analysis of patters (e.g., labyrinths, letters and angles) was conducted in order to select three very distinguishable levels of difficulty that could be included in the system, and which would yield the greatest benefit in terms of assessment of coordination and strength issues as well as in training. Support algorithms (position, force, velocity, inertia and viscosity) were also developed and incorporated into the tasks in order to introduce general computer assistance to the mapping of the user's movements to the computer screen without overriding the user's commands to the robotic device. In order to evaluate performance (given by %accuracy and time) of the executed tasks, a sophisticated evaluation function was designed based on image analysis and edge detection algorithms. This paper presents the development of the haptic tasks, the various assistance algorithms, the description of the evaluation function and the results of a study implemented at the Motor Development Clinic at Cal Poly Pomona. The results (Accuracy and Time) of this function are currently being used as inputs to an Intelligent Decision Support System (described in), which in turn, suggests the next task to be executed by the subject based on his/her performance. © 2011 IEEE

  2. Clinical evaluation of the effect of diquafosol ophthalmic solution in glaucoma patients with dry eye syndrome.

    Science.gov (United States)

    Jin, Sang Wook; Min, Ji Sang

    2016-05-01

    To investigate the effects of diquafosol on intraocular pressure (IOP) and dry eye symptoms in glaucoma patients with dry eye syndrome (DES). This study evaluated a total of 138 glaucoma patients with DES who were treated with diquafosol ophthalmic solution (DIQUAS(®)). Before treatment and 1, 4, 12, 36, and 52 weeks after treatment, IOP, ocular surface disease index (OSDI), tear film break-up time (BUT), Schirmer I test scores, fluorescein staining, conjunctival impression cytology, and adverse drug reactions were evaluated. Throughout the treatment period, the mean IOP for all the patients remained stable after treatment with diquafosol (15.4 ± 2.8 mmHg at baseline and 16.0 ± 2.8 mmHg at 52 weeks). The mean OSDI score improved significantly at 4, 12, and 52 weeks after diquafosol treatment. The BUT and Schirmer I test scores were significantly increased after diquafosol treatment. The Oxford scheme score was significantly decreased at 1, 4, 12, 36, and 52 weeks after diquafosol treatment. A significant improvement in goblet cell density was observed after 4 weeks of treatment with diquafosol. Adverse drug reactions were reported in 22 (15.9 %) patients. There were no serious adverse drug reactions. Diquafosol was effective in improving objective and subjective symptoms and maintained a stable IOP in glaucoma patients with DES. Therefore, the addition of diquafosol treatment in glaucoma patients with DES or ocular surface side effects using anti-glaucoma medication may be beneficial.

  3. Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes.

    Science.gov (United States)

    Wong, Hon-Tym; Chua, Jocelyn L L; Sakata, Lisandro M; Wong, Melissa H Y; Aung, Han T; Aung, Tin

    2009-05-01

    To evaluate the effectiveness of slitlamp optical coherence tomography (SL-OCT) and Scanning Peripheral Anterior Chamber depth analyzer (SPAC) in detecting angle closure, using gonioscopy as the reference standard. A total of 153 subjects underwent gonioscopy, SL-OCT, and SPAC. The anterior chamber angle (ACA) was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen; with SL-OCT, closure was determined by contact between the iris and angle wall anterior to the scleral spur; and with SPAC by a numerical grade of 5 or fewer and/or a categorical grade of suspect or potential. A closed ACA was identified in 51 eyes with gonioscopy, 86 eyes with SL-OCT, and 61 eyes with SPAC (gonioscopy vs SL-OCT, P gonioscopy vs SPAC, P = .10; SL-OCT vs SPAC, P gonioscopy, SL-OCT detected a closed ACA in 43, whereas SPAC identified 41 (P = .79). An open angle in all 4 quadrants was observed in 102 eyes with gonioscopy, but SL-OCT and SPAC identified 43 and 20 of these eyes, respectively, as having angle closure. The overall sensitivity and specificity for SL-OCT were 84% and 58% vs 80% and 80% for SPAC. Using gonioscopy as the reference, SL-OCT and SPAC showed good sensitivity for detecting eyes at risk of angle closure.

  4. Evaluation of eyes with relative pupillary block by indentation ultrasound biomicroscopy gonioscopy.

    Science.gov (United States)

    Matsunaga, Koichi; Ito, Kunio; Esaki, Koji; Sugimoto, Kota; Sano, Toru; Miura, Katsuya; Sasoh, Mikio; Uji, Yukitaka

    2004-03-01

    To investigate changes in anterior chamber angle configuration with indentation ultrasound biomicroscopy gonioscopy of relative pupillary block (RPB). Cross-sectional study. This study included 26 eyes of 26 patients with RPB. We determined angle opening distance 500 and angle recess area using indentation ultrasound biomicroscopy gonioscopy and compared a small-sized standard eye cup with a new eye cup with an area for inducing pressure. Indentation ultrasound biomicroscopy images documented concavity of the iris in eyes with RPB. Both the new and the small standard eye cups widened the anterior chamber angle significantly (P gonioscopy is a useful technique for observation and diagnosis of RPB. Using a small standard or the newly designed eye cup, the procedure can be performed easily and without causing corneal damage.

  5. Diquafosol sodium ophthalmic solution for the treatment of dry eye: clinical evaluation and biochemical analysis of tear composition.

    Science.gov (United States)

    Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko; Tsubota, Kazuo

    2015-11-01

    To evaluate the clinical efficacy of 3% diquafosol sodium ophthalmic solution for dry eye, and to analyze the concentration of tear proteins and mucin-like substances after the treatment. Fifty eyes of 25 patients with dry eye syndrome were prospectively enrolled. The patients were treated with diquafosol solution at a dose of 1 drop in each eye 6 times daily for 4 weeks. The parameters of clinical efficacy were tear osmolarity, tear breakup time (BUT), fluorescein staining scores for the cornea and conjunctiva, Schirmer test values, and subjective symptoms evaluated using the ocular surface disease index (OSDI). Tears collected with Schirmer test strips were analyzed by high-performance liquid chromatography, and the concentrations of the total protein and the 4 major tear proteins, namely, secretory IgA, lactoferrin, lipocalin-1, lysozyme, and N-acetyl-neuraminic acid (Neu5Ac), were measured. Neu5Ac is a major sialic acid, a marker of secretory mucins. The BUT, keratoconjunctival staining scores, and Schirmer test values were improved with statistical significance after the treatment with diquafosol solution, while changes in the other parameters, including tear osmolarity, corneal staining scores, and OSDI scores were not significant. The Neu5Ac concentration was significantly increased, which was not accompanied by changes in tear proteins. Topical application of diquafosol significantly improved the clinical parameters of the BUT, keratoconjunctival staining scores, and Schirmer test values and was accompanied by increased sialic acid content in the tears of patients with dry eye.

  6. Implementation evaluation of a culturally competent eye injury prevention program for citrus workers in a Florida migrant community.

    Science.gov (United States)

    Luque, John S; Monaghan, Paul; Contreras, Ricardo B; August, Euna; Baldwin, Julie A; Bryant, Carol A; McDermott, Robert J

    2007-01-01

    The Partnership for Citrus Worker Health (PCWH) is a coalition that connects academic institutions, public health agencies, industry and community-based organizations for implementation of an eye safety pilot project with citrus workers using the Camp Health Aide (CHA) model. This project was an implementation evaluation of an eye safety curriculum using modeling and peer-to-peer education among Mexican migrant citrus workers in a southwest Florida community to increase positive perceptions toward the use of safety eyewear and reduce occupational eye injuries. CHAs have been employed and trained in eye safety and health during harvesting seasons since 2004. Field observations, focus group interviews, and written questionnaires assessed program implementation and initial outcomes. There was an increase in positive perceptions toward use of safety eyewear between 2004 and 2005. Evaluation of training suggested ways to improve the curriculum. The modest literacy level of the CHAs necessitated some redesign of the curriculum and its implementation (e.g., introduction of and more reliance on use of training posters). PCWH benefited by extensive documentation of the training and supervision, a pilot project that demonstrated the potential effectiveness of CHAs, and having a well-defined target population of citrus workers (n = 427). Future research can rigorously test the effectiveness of CHAs in reducing eye injuries among citrus workers.

  7. Vitamin B12 deficiency evaluation and treatment in severe dry eye disease with neuropathic ocular pain.

    Science.gov (United States)

    Ozen, Serkan; Ozer, Murat Atabey; Akdemir, Mehmet Orçun

    2017-06-01

    This study aims to understand the effect of vitamin B12 deficiency on neuropathic ocular pain (NOP) and symptoms in patients with dry eye disease (DED). Patients with severe DED (without receiving topical artificial tears treatment) and ocular pain were enrolled (n = 90). Patients with severe DED and vitamin B12 deficiency (group 1, n = 45) received parenteral vitamin B12 supplement + topical treatment (artificial tears treatment + cyclosporine), and patients with severe DED and normal serum vitamin B12 level (group 2, n = 45) received only topical treatment (artificial tears treatment + cyclosporine). Patients were evaluated by the ocular surface disease index (OSDI) questionnaire, 3rd question (have you experienced painful or sore eyes during last week?) score of OSDI as a pain determiner and pain frequency measure), tear break up time (TBUT), and Schirmer's type 1 test. We compared the groups' OSDI, TBUT, and Schirmer's test recordings at the first visit and after 12 weeks retrospectively. The OSDI score, 3rd OSDI question score, TBUT, and Schirmer's test results improved after 12 weeks (p treatment. The mean score changes between the groups were not statistically significant; however, the decrease in the OSDI questionnaire score (-30.80 ±5.24) and 3rd OSDI question score (-2.82 ±0.53) were remarkable in group 1 (Table 2). The mean TBUT increase was +7.98 ±2.90 s and Schirmer's test result increase was +12.16 ±2.01 mm in group 1. The mean TBUT increase was +6.18 ±1.49 s and Schirmer's test result increase was +6.71 ±1.47 mm in group 2. These findings indicate that vitamin B12 deficiency is related with NOP. It may be important to consider measuring the serum vitamin B12 level in patients with severe DED presenting with resistant ocular pain despite taking topical treatment.

  8. On lamps, walls, and eyes: The spectral radiance field and the evaluation of light pollution indoors

    Science.gov (United States)

    Bará, Salvador; Escofet, Jaume

    2018-01-01

    Light plays a key role in the regulation of different physiological processes, through several visual and non-visual retinal phototransduction channels whose basic features are being unveiled by recent research. The growing body of evidence on the significance of these effects has sparked a renewed interest in the determination of the light field at the entrance pupil of the eye in indoor spaces. Since photic interactions are strongly wavelength-dependent, a significant effort is being devoted to assess the relative merits of the spectra of the different types of light sources available for use at home and in the workplace. The spectral content of the light reaching the observer eyes in indoor spaces, however, does not depend exclusively on the sources: it is partially modulated by the spectral reflectance of the walls and surrounding surfaces, through the multiple reflections of the light beams along all possible paths from the source to the observer. This modulation can modify significantly the non-visual photic inputs that would be produced by the lamps alone, and opens the way for controlling-to a certain extent-the subject's exposure to different regions of the optical spectrum. In this work we evaluate the expected magnitude of this effect and we show that, for factorizable sources, the spectral modulation can be conveniently described in terms of a set of effective filter-like functions that provide useful insights for lighting design and light pollution assessment. The radiance field also provides a suitable bridge between indoor and outdoor light pollution studies.

  9. Eye Allergies

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Eye Allergies Sections What Are Eye Allergies? Eye Allergy Symptoms ... allergy diagnosis Eye allergy treatment What Are Eye Allergies? Leer en Español: ¿Qué son las alergias de ...

  10. 77 FR 41406 - Evaluation of In Vitro Tests for Identifying Eye Injury Hazard Potential of Chemicals and...

    Science.gov (United States)

    2012-07-13

    ...://www.epa.gov/oppad001/eye-irritation.pdf ). The IRE test is an organotypic test method that evaluates... rabbit corneal epithelial cells following test substance exposure (Takahashi et al., 2008). NICEATM is..., mailing address, phone, fax, email, and sponsoring organization, as applicable). NICEATM prefers that data...

  11. Optic Disc and Retinal Nerve Fiber Layer Thickness Evaluation of the Fellow Eyes in Non-Arteritic Ischemic Optic Neuropathy

    Directory of Open Access Journals (Sweden)

    Medine Yılmaz Dağ

    2015-05-01

    Full Text Available Objectives: To examine the fellow eyes in unilateral non-arteritic ischemic optic neuropathy (NAION and to compare their optic disc parameters and peripapillary retinal nerve fiber layer (RNFL thickness with age-and refraction-matched normal controll subjects, using Heidelberg Retinal Tomograph 2 (HRT II. Materials and Methods: The fellow eyes of 40 patients with typical unilateral NAION (study group and one randomly chosen eye of 42 age-, sex-, and refraction-matched normal control subjects were enrolled in the study. Optic disc morphologic features (average disc area, cup area, rim area, disc volume, rim volume, cup/disc area ratio, cup depth and peripapillary RNFL thickness were evaluated using HRT II, a confoal scanning ophtalmoscopy. Results: In the study group, there were 26 (65% men and 14 (35% women, whereas there were 27 (64% men and 15 (36% women in the control group (Chi square test, p=0.89. Mean age of the patients in the study and control groups was 59.4±10.3 and 57.7±9.1 years, respectively (T test, p=0.72. There was not any statistically significant difference regarding mean spheric equivalent between the two groups (Mann-Whitney U-test, p=0.203. The NAION unaffected fellow eyes had significantly smaller disc areas, cup areas, cup volumes, cup-disc area ratios (vertical and lineer, and cup depths than the control eyes (Mann-Whitney U-test; p<0.05, whereas there was no significant difference in the RNFL thickness between the two. Conclusion: A comparison of the fellow eyes in patients with unilateral NAION and the control eyes showed a significant difference in optic disc parameters and the morphology of RNFL. These differences could be important in the pathogenesis of NAION and needs to have further investigated. (Turk J Ophthalmol 2015; 45: 111-114

  12. A and B mode ultrasonography in preoperative evaluation of lens and posterior segment of dogs eyes with cataract

    Directory of Open Access Journals (Sweden)

    Bianca C. Martins

    2010-02-01

    Full Text Available Ultrasonography of the lens and posterior segment is an indispensable step in the preoperative evaluation of dogs with cataracts, since ophthalmoscopy is not feasible when there is opacification of the lens. This study evaluated the echographic conditions of cataractous lens and fundus of the eye in dogs affected by cataracts. The study was conducted in 30 dogs (56 eyes, 10 males and 20 females, with different types of cataracts at different stages of development. Echography in A and B modes, simultaneously, was carried out for the examination of the lens and posterior segment. The examinations revealed anterior cortical, posterior cortical and nuclear cataract in 12 eyes (21.4%, anterior cortical, posterior cortical, nuclear and posterior capsular in 23 eyes (41%, anterior cortical, posterior cortical and posterior capsular cataract in one eye (1.7%, anterior cortical and nuclear cataract in one eye (1.7%, anterior cortical, nuclear and posterior capsular cataract in five eyes (8.9%, and anterior cortical cataract in seven eyes (12.5%. Abnormal ultrasonographic alterations were observed in the posterior segment in 26 eyes evaluated (46.4%. Vitreal degeneration was detected in 12 eyes (21.4%, images of vitreal exudate or hemorrhage in seven eyes (12.5%, persistence of hyaloid artery in four eyes (7.1% and lens subluxation in three eyes (5.3%. The results obtained reiterate the importance of ultrasonography in canine patients presented for cataract surgery given that alterations of the posterior segment are difficult to identify in a clinical examination when the lens is opacified.A ultrassonografia do segmento posterior do bulbo do olho é etapa indispensável na avaliação de cães com catarata que serão submetidos à facectomia, uma vez que a oftalmoscopia não é factível quando há opacificação da lente, notadamente nas cataratas maduras. Este estudo avaliou as condições ecográficas da lente cataratogênica e do fundo de olho de c

  13. Evaluation of a Novel Artificial Tear in the Prevention and Treatment of Dry Eye in an Animal Model.

    Science.gov (United States)

    She, Yujing; Li, Jinyang; Xiao, Bing; Lu, Huihui; Liu, Haixia; Simmons, Peter A; Vehige, Joseph G; Chen, Wei

    2015-11-01

    To evaluate effects of a novel multi-ingredient artificial tear formulation containing carboxymethylcellulose (CMC) and hyaluronic acid (HA) in a murine dry eye model. Dry eye was induced in mice (C57BL/6) using an intelligently controlled environmental system (ICES). CMC+HA (Optive Fusion™), CMC-only (Refresh Tears(®)), and HA-only (Hycosan(®)) artificial tears and control phosphate-buffered saline (PBS) were administered 4 times daily and compared with no treatment (n = 64 eyes per group). During regimen 1 (prevention regimen), mice were administered artificial tears or PBS for 14 days (starting day 0) while they were exposed to ICES, and assessed on days 0 and 14. During regimen 2 (treatment regimen), mice exposed to ICES for 14 days with no intervention were administered artificial tears or PBS for 14 days (starting day 14) while continuing exposure to ICES, and assessed on days 0, 14, and 28. Corneal fluorescein staining and conjunctival goblet cell density were measured. Artificial tear-treated mice had significantly better outcomes than control groups on corneal staining and goblet cell density (P dry eye. Improvements observed for corneal fluorescein staining and conjunctival goblet cell retention suggest that this combination may be a viable treatment option for dry eye disease.

  14. Effect of Autologous Serum Eye Drops in Patients with Sjögren Syndrome-related Dry Eye: Clinical and In Vivo Confocal Microscopy Evaluation of the Ocular Surface.

    Science.gov (United States)

    Semeraro, Francesco; Forbice, Eliana; Nascimbeni, Giuseppe; Taglietti, Marco; Romano, Vito; Guerra, Germano; Costagliola, Ciro

    To evaluate in vivo changes after therapy using autologous serum (AS) eye drops in Sjögren's syndrome (SS)-related dry eyes by confocal microscopy. In this study, 24 patients with SS-related dry eyes [12 in AS eye drop therapy and 12 in artificial tear (AT) therapy] and 24 healthy volunteers were recruited. Ocular Surface Disease Index (OSDI), central corneal thickness, tear film, break-up time, corneal and conjunctival staining, Schirmer's test and corneal confocal microscopy were investigated. Tear production, tear stability, corneal staining, inflammation, and central corneal thickness, Langherans cells, activated keratocytes, intermediate epithelial cell density, nerve tortuosity, number of sub-basal nerve branches, and number of bead-like formations differed between patients and controls (peye drops improve symptoms and confocal microscopy findings in SS-related dry eyes. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  15. IMAGE-GUIDED EVALUATION AND MONITORING OF TREATMENT RESPONSE IN PATIENTS WITH DRY EYE DISEASE

    Science.gov (United States)

    Hamrah, Pedram

    2014-01-01

    Dry eye disease (DED) is one of the most common ocular disorders worldwide. The pathophysiological mechanisms involved in the development of DED are not well understood and thus treating DED has been a significant challenge for ophthalmologists. Most of the currently available diagnostic tests demonstrate low correlation to patient symptoms and have low reproducibility. Recently, sophisticated in vivo imaging modalities have become available for patient care, namely, in vivo confocal microscopy (IVCM) and optical coherence tomography (OCT). These emerging modalities are powerful and non-invasive, allowing real-time visualization of cellular and anatomical structures of the cornea and ocular surface. Here we discuss how, by providing both qualitative and quantitative assessment, these techniques can be used to demonstrate early subclinical disease, grade layer-by-layer severity, and allow monitoring of disease severity by cellular alterations. Imaging-guided stratification of patients may also be possible in conjunction with clinical examination methods. Visualization of subclinical changes and stratification of patients in vivo, allows objective image-guided evaluation of tailored treatment response based on cellular morphological alterations specific to each patient. This image-guided approach to DED may ultimately improve patient outcomes and allow studying the efficacy of novel therapies in clinical trials. PMID:24696045

  16. Connecting eye to eye

    DEFF Research Database (Denmark)

    Dau, Susanne; Rask, Anders Bindslev

    2017-01-01

    Computer Supported Collaborative Learning (CSCL) is used a frame for supporting online and blended learning in educations. The online communication and collaboration are afforded by the social collaboration. However, the social collaboration is based on the establishment of direct eye contact...... (Khalid, Deska & Hugenberg, 2016), but direct eye contact is challenged by the position of the digital devices and thus CSCL. Lack of eye contact is the chief contributor to the negative effects of online disinhibition (Lapidot-Lefler & Barak, 2012) and the problem is the location of the web camera...... at the computer. Eye contact is challenged by the displacement between the senders´ and receivers´ focus on the screen picture and the camera's location at the top or bottom of screens on all digital devices. The aim of this paper is accordingly to investigate the influence of the displacement in eye contact...

  17. Imaging shear stress distribution and evaluating the stress concentration factor of the human eye

    Science.gov (United States)

    Joseph Antony, S.

    2015-03-01

    Healthy eyes are vital for a better quality of human life. Historically, for man-made materials, scientists and engineers use stress concentration factors to characterise the effects of structural non-homogeneities on their mechanical strength. However, such information is scarce for the human eye. Here we present the shear stress distribution profiles of a healthy human cornea surface in vivo using photo-stress analysis tomography, which is a non-intrusive and non-X-ray based method. The corneal birefringent retardation measured here is comparable to that of previous studies. Using this, we derive eye stress concentration factors and the directional alignment of major principal stress on the surface of the cornea. Similar to thermometers being used for monitoring the general health in humans, this report provides a foundation to characterise the shear stress carrying capacity of the cornea, and a potential bench mark for validating theoretical modelling of stresses in the human eye in future.

  18. Evaluation of thyroid eye disease: quality-of-life questionnaire (TED-QOL) in Korean patients.

    Science.gov (United States)

    Son, Byeong Jae; Lee, Sang Yeul; Yoon, Jin Sook

    2014-04-01

    To assess impaired quality of life (QOL) of Korean patients with thyroid eye disease (TED) using the TED-QOL questionnaire, to evaluate the adaptability of the questionnaire, and to assess the correlation between TED-QOL and scales of disease severity. Prospective, cross-sectional study. Total of 90 consecutive adult patients with TED and Graves' disease were included in this study. TED-QOL was translated into Korean and administered to the patients. The results were compared with clinical severity scores (clinical activity score, VISA (vision loss (optic neuropathy); inflammation; strabismus/motility; appearance/exposure) classification, modified NOSPECS (no signs or symptoms; only signs; soft tissue; proptosis; extraocular muscle; cornea; sight loss) score, Gorman diplopia scale, and European Group of Graves' Orbitopathy Classification). Clinical scores indicating inflammation and strabismus in patients with TED were positively correlated with overall and visual function-related QOL (Spearman coefficient 0.21-0.38, p < 0.05). Clinical scores associated with appearance were positively correlated with appearance-related QOL (Spearman coefficient 0.26-0.27, p < 0.05). In multivariate analysis, age, soft-tissue inflammation, motility disorder of modified NOSPECS, and motility disorder of VISA classification had positive correlation with overall and function-related QOL. Sex, soft-tissue inflammation, proptosis of modified NOSPECS, and appearance of VISA classification had correlation with appearance-related QOL. In addition, validity of TED-QOL was proved sufficient based on the outcomes of patient interviews and correlation between the subscales of TED-QOL. TED-QOL showed significant correlations with various objective clinical parameters of TED. TED-QOL was a simple and useful tool for rapid evaluation of QOL in daily outpatient clinics, which could be readily translated into different languages to be widely applicable to various populations. Copyright © 2014

  19. EVALUATION OF IRIDOCILIARY AND LENTICULAR ELASTICITY USING SHEAR-WAVE ELASTOGRAPHY IN RABBIT EYES

    OpenAIRE

    Efstathios T. Detorakis; Eleni E. Drakonaki; Harilaos Ginis; Nikolaos Karyotakis; Ioannis G. Pallikaris

    2014-01-01

    Introduction: A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. Methods: Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and an...

  20. Real-time sharing of gaze data between multiple eye trackers-evaluation, tools, and advice.

    Science.gov (United States)

    Nyström, Marcus; Niehorster, Diederick C; Cornelissen, Tim; Garde, Henrik

    2017-08-01

    Technological advancements in combination with significant reductions in price have made it practically feasible to run experiments with multiple eye trackers. This enables new types of experiments with simultaneous recordings of eye movement data from several participants, which is of interest for researchers in, e.g., social and educational psychology. The Lund University Humanities Laboratory recently acquired 25 remote eye trackers, which are connected over a local wireless network. As a first step toward running experiments with this setup, demanding situations with real time sharing of gaze data were investigated in terms of network performance as well as clock and screen synchronization. Results show that data can be shared with a sufficiently low packet loss (0.1 %) and latency (M = 3 ms, M A D = 2 ms) across 8 eye trackers at a rate of 60 Hz. For a similar performance using 24 computers, the send rate needs to be reduced to 20 Hz. To help researchers conduct similar measurements on their own multi-eye-tracker setup, open source software written in Python and PsychoPy are provided. Part of the software contains a minimal working example to help researchers kick-start experiments with two or more eye trackers.

  1. Evaluation of head-free eye tracking as an input device for air traffic control.

    Science.gov (United States)

    Alonso, Roland; Causse, Mickaël; Vachon, François; Parise, Robert; Dehais, Frédéric; Terrier, Patrice

    2013-01-01

    The purpose of this study was to investigate the possibility to integrate a free head motion eye-tracking system as input device in air traffic control (ATC) activity. Sixteen participants used an eye tracker to select targets displayed on a screen as quickly and accurately as possible. We assessed the impact of the presence of visual feedback about gaze position and the method of target selection on selection performance under different difficulty levels induced by variations in target size and target-to-target separation. We tend to consider that the combined use of gaze dwell-time selection and continuous eye-gaze feedback was the best condition as it suits naturally with gaze displacement over the ATC display and free the hands of the controller, despite a small cost in terms of selection speed. In addition, target size had a greater impact on accuracy and selection time than target distance. These findings provide guidelines on possible further implementation of eye tracking in ATC everyday activity. We investigated the possibility to integrate a free head motion eye-tracking system as input device in air traffic control (ATC). We found that the combined use of gaze dwell-time selection and continuous eye-gaze feedback allowed the best performance and that target size had a greater impact on performance than target distance.

  2. A Fuzzy-Based Fusion Method of Multimodal Sensor-Based Measurements for the Quantitative Evaluation of Eye Fatigue on 3D Displays

    Directory of Open Access Journals (Sweden)

    Jae Won Bang

    2015-05-01

    Full Text Available With the rapid increase of 3-dimensional (3D content, considerable research related to the 3D human factor has been undertaken for quantitatively evaluating visual discomfort, including eye fatigue and dizziness, caused by viewing 3D content. Various modalities such as electroencephalograms (EEGs, biomedical signals, and eye responses have been investigated. However, the majority of the previous research has analyzed each modality separately to measure user eye fatigue. This cannot guarantee the credibility of the resulting eye fatigue evaluations. Therefore, we propose a new method for quantitatively evaluating eye fatigue related to 3D content by combining multimodal measurements. This research is novel for the following four reasons: first, for the evaluation of eye fatigue with high credibility on 3D displays, a fuzzy-based fusion method (FBFM is proposed based on the multimodalities of EEG signals, eye blinking rate (BR, facial temperature (FT, and subjective evaluation (SE; second, to measure a more accurate variation of eye fatigue (before and after watching a 3D display, we obtain the quality scores of EEG signals, eye BR, FT and SE; third, for combining the values of the four modalities we obtain the optimal weights of the EEG signals BR, FT and SE using a fuzzy system based on quality scores; fourth, the quantitative level of the variation of eye fatigue is finally obtained using the weighted sum of the values measured by the four modalities. Experimental results confirm that the effectiveness of the proposed FBFM is greater than other conventional multimodal measurements. Moreover, the credibility of the variations of the eye fatigue using the FBFM before and after watching the 3D display is proven using a t-test and descriptive statistical analysis using effect size.

  3. EVALUATION OF EYE LENS DOSE TO WORKERS IN THE STEAM GENERATOR AT THE KOREAN OPTIMIZED POWER REACTOR 1000.

    Science.gov (United States)

    Maeng, Sung Jun; Kim, Jinhwan; Cho, Gyuseong

    2018-03-15

    ICRP (2011) revised the dose limit to the eye lens to 20 mSv/y based on a recent epidemiological study of radiation-induced cataracts. Maintenance of steam generators at nuclear power plants is one of the highest radiation-associated tasks within a non-uniform radiation field. This study aims to evaluate eye lens doses in the steam generators of the Korean OPR1000 design. The source term was characterized based on the CRUD-specific activity, and both the eye lens dose and organ dose were simulated using MCNP6 combined with an ICRP voxel phantom and a mesh phantom, respectively. The eye lens dose was determined to be 5.39E-02-9.43E-02 Sv/h, with a negligible effect by beta particles. As the effective dose was found to be 0.81-1.21 times the lens equivalent dose depending on the phantom angles, the former can be used to estimate the lens dose in the SG of the OPR1000 for radiation monitoring purposes.

  4. Dry eye evaluation and correlation analysis between tear film stability and corneal surface regularity after small incision lenticule extraction.

    Science.gov (United States)

    Zhang, Hui; Wang, Yan

    2017-09-22

    To investigate the dry eye after small incision lenticule extraction (SMILE) and explore the correlations between changes in the tear film stability, the tear secretion and the corneal surface regularity. Sixty-two eyes of 22 men and 13 women who underwent SMILE were included in this study. Corneal topography was measured to assess the index of surface variance (ISV) and the index of vertical asymmetry (IVA). Dry eye tests including subjective symptom questionnaire, tear breakup time (TBUT), corneal fluorescein staining and Schirmer's test (ST) were evaluated before and at 1 and 6 months postoperatively. TBUT was found to be significantly decreased from 9.8 ± 3.4 s preoperatively to 7.4 ± 3.8 s at 1 month and 6.5 ± 3.6 s at 6 months (both P short-TBUT type of dry eye. Corneal surface regularity indices might be helpful in the assessment of tear film stability following SMILE procedure.

  5. Automated Grading System for Evaluation of Superficial Punctate Keratitis Associated With Dry Eye.

    Science.gov (United States)

    Rodriguez, John D; Lane, Keith J; Ousler, George W; Angjeli, Endri; Smith, Lisa M; Abelson, Mark B

    2015-04-01

    To develop an automated method of grading fluorescein staining that accurately reproduces the clinical grading system currently in use. From the slit lamp photograph of the fluorescein-stained cornea, the region of interest was selected and punctate dot number calculated using software developed with the OpenCV computer vision library. Images (n = 229) were then divided into six incremental severity categories based on computed scores. The final selection of 54 photographs represented the full range of scores: nine images from each of six categories. These were then evaluated by three investigators using a clinical 0 to 4 corneal staining scale. Pearson correlations were calculated to compare investigator scores, and mean investigator and automated scores. Lin's Concordance Correlation Coefficients (CCC) and Bland-Altman plots were used to assess agreement between methods and between investigators. Pearson's correlation between investigators was 0.914; mean CCC between investigators was 0.882. Bland-Altman analysis indicated that scores assessed by investigator 3 were significantly higher than those of investigators 1 and 2 (paired t-test). The predicted grade was calculated to be: Gpred = 1.48log(Ndots) - 0.206. The two-point Pearson's correlation coefficient between the methods was 0.927 (P < 0.0001). The CCC between predicted automated score Gpred and mean investigator score was 0.929, 95% confidence interval (0.884-0.957). Bland-Altman analysis did not indicate bias. The difference in SD between clinical and automated methods was 0.398. An objective, automated analysis of corneal staining provides a quality assurance tool to be used to substantiate clinical grading of key corneal staining endpoints in multicentered clinical trials of dry eye.

  6. THROUGH THE EYES OF THE LEARNER: A CRITICAL EVALUATION OF AN URBAN INDIAN SCHOOL

    Directory of Open Access Journals (Sweden)

    Smita Khan

    2012-07-01

    Full Text Available India, being the second most populated country in the world, a sizable school going population is the result of a positive and proactive response to the governmental efforts on basic education. This has catapulted the responsibility of schools and their environs in shaping young impressionable minds due to their sheer number. This study aims at exploring and investigating qualities and characteristics of an urban Indian school through critical post occupancy evaluation of the school environs through the eyes of the children. To initiate this study, a premier school of Nagpur city, exemplifying a typical urban school, was identified for a pilot study. The methodology encompassed interviewing the Principal, observation by the researchers and interaction with students to understand and critically analyze usage pattern by principal users of the school. The design of the tools for user response was devised keeping in mind the age of the students and their ability to communicate spatial experiences. The paper served as a fact-finding mission and in its outcomes led to an identification of the major variables of the spatial environs of schools. It brought to fore an understanding, which the mandatory prerequisites of school infrastructure lack in a humane vision that is so imperative to educational environments. It facilitated in pinpointing the lacunae existing in the National Curriculum Framework, which is a governmental guideline for all schools in India. In conclusion, the article emphasizes the urgency in the necessary ‘humanization’ of the schools to the happiness and contentment of the young who are nurtured within its spaces.

  7. Eye-Tracking as a Tool to Evaluate Functional Ability in Everyday Tasks in Glaucoma

    Directory of Open Access Journals (Sweden)

    Enkelejda Kasneci

    2017-01-01

    Full Text Available To date, few studies have investigated the eye movement patterns of individuals with glaucoma while they undertake everyday tasks in real-world settings. While some of these studies have reported possible compensatory gaze patterns in those with glaucoma who demonstrated good task performance despite their visual field loss, little is known about the complex interaction between field loss and visual scanning strategies and the impact on task performance and, consequently, on quality of life. We review existing approaches that have quantified the effect of glaucomatous visual field defects on the ability to undertake everyday activities through the use of eye movement analysis. Furthermore, we discuss current developments in eye-tracking technology and the potential for combining eye-tracking with virtual reality and advanced analytical approaches. Recent technological developments suggest that systems based on eye-tracking have the potential to assist individuals with glaucomatous loss to maintain or even improve their performance on everyday tasks and hence enhance their long-term quality of life. We discuss novel approaches for studying the visual search behavior of individuals with glaucoma that have the potential to assist individuals with glaucoma, through the use of personalized programs that take into consideration the individual characteristics of their remaining visual field and visual search behavior.

  8. EVALUATION OF IRIDOCILIARY AND LENTICULAR ELASTICITY USING SHEAR-WAVE ELASTOGRAPHY IN RABBIT EYES

    Directory of Open Access Journals (Sweden)

    Efstathios T. Detorakis

    2014-01-01

    Full Text Available Introduction: A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. Methods: Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and anterior chamber depth were taken with the Aixplorer system (SuperSonic Imagine, Aix-en-Provence, France with the SuperLinear™ SL 15-4 transducer in both eyes at baseline as well as after pilocarpine and atropine instillation. The IOP was also measured with the TonoPen tonometer. Results: Changes in rigidity in the examined areas following atropine instillation were statistically not significant. Ciliary body rigidity was significantly increased whereas lens and total ocular rigidity were significantly reduced following pilocarpine instillation. The decrease in lens rigidity following pilocarpine was significantly associated with the respective increase in ciliary body rigidity. Conclusions: Shear-wave ultrasound elastography can detect in vivo rigidity changes in the anterior segment of the rabbit eye model and may potentially be applied in human eyes, providing useful clinical information on conditions in which rigidity changes play an important role, such as glaucoma, pseudoexfoliation syndrome or presbyopia.

  9. Evaluation of iridociliary and lenticular elasticity using shear-wave elastography in rabbit eyes.

    Science.gov (United States)

    Detorakis, Efstathios T; Drakonaki, Eleni E; Ginis, Harilaos; Karyotakis, Nikolaos; Pallikaris, Ioannis G

    2014-01-01

    A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and anterior chamber depth were taken with the Aixplorer system (SuperSonic Imagine, Aix-en-Provence, France) with the SuperLinear™ SL 15-4 transducer in both eyes at baseline as well as after pilocarpine and atropine instillation. The IOP was also measured with the TonoPen tonometer. Changes in rigidity in the examined areas following atropine instillation were statistically not significant. Ciliary body rigidity was significantly increased whereas lens and total ocular rigidity were significantly reduced following pilocarpine instillation. The decrease in lens rigidity following pilocarpine was significantly associated with the respective increase in ciliary body rigidity. Shear-wave ultrasound elastography can detect in vivo rigidity changes in the anterior segment of the rabbit eye model and may potentially be applied in human eyes, providing useful clinical information on conditions in which rigidity changes play an important role, such as glaucoma, pseudoexfoliation syndrome or presbyopia.

  10. Children’s Empathy and Their Perception and Evaluation of Facial Pain Expression: An Eye Tracking Study

    Directory of Open Access Journals (Sweden)

    Zhiqiang Yan

    2017-12-01

    Full Text Available The function of empathic concern to process pain is a product of evolutionary adaptation. Focusing on 5- to 6-year old children, the current study employed eye-tracking in an odd-one-out task (searching for the emotional facial expression among neutral expressions, N = 47 and a pain evaluation task (evaluating the pain intensity of a facial expression, N = 42 to investigate the relationship between children’s empathy and their behavioral and perceptual response to facial pain expression. We found children detected painful expression faster than others (angry, sad, and happy, children high in empathy performed better on searching facial expression of pain, and gave higher evaluation of pain intensity; and rating for pain in painful expressions was best predicted by a self-reported empathy score. As for eye-tracking in pain detection, children fixated on pain more quickly, less frequently and for shorter times. Of facial clues, children fixated on eyes and mouth more quickly, more frequently and for longer times. These results implied that painful facial expression was different from others in a cognitive sense, and children’s empathy might facilitate their search and make them perceive the intensity of observed pain on the higher side.

  11. Comparative Evaluation of the Corneal and Anterior Chamber Parameters Derived From Scheimpflug Imaging in Arab and South Asian Normal Eyes.

    Science.gov (United States)

    Prakash, Gaurav; Srivastava, Dhruv; Avadhani, Kavitha; Thirumalai, Sandeep M; Choudhuri, Sounak

    2015-11-01

    To evaluate the differences in the normal corneal and anterior segment Scheimpflug parameters in Arab and South Asian eyes. This hospital-based study was performed at a cornea and refractive surgery service in Abu Dhabi. A total of 600 consecutive normal candidates of South Asian (group 1, n = 300) and Arab (group 2, n = 300) origins underwent Scheimpflug imaging (Sirius; Costruzione Strumenti Oftalmici, Italy). One eye was randomly selected for evaluation. The age and sex distributions in both groups were comparable. The pachymetric variables were statistically higher in group 2 (group 2 vs. group 1, 544.3 ± 32.2 μm vs. 535.1 ± 31.4 μm for central corneal thickness, 541.0 ± 32.6 μm vs. 531.9 ± 31.5 μm for minimum corneal thickness, 571.7 ± 43.2 μm vs. 558.1 ± 42.3 μm for apical thickness, and 58.1 ± 4.2 vs. 57.3 ± 4.3 mm³ for the corneal volume; P Arab ethnicity tend to have statistically thicker and flatter corneas and less-crowded anterior segments than those of the South Asian counterparts. These epidemiological differences have a mild to moderate biological effect size (Cohen d), but they should be considered when evaluating these eyes for anterior segment or corneal procedures.

  12. Modeling and evaluation of hand-eye coordination of surgical robotic system on task performance.

    Science.gov (United States)

    Gao, Yuanqian; Wang, Shuxin; Li, Jianmin; Li, Aimin; Liu, Hongbin; Xing, Yuan

    2017-12-01

    Robotic-assisted minimally invasive surgery changes the direct hand and eye coordination in traditional surgery to indirect instrument and camera coordination, which affects the ergonomics, operation performance, and safety. A camera, two instruments, and a target, as the descriptors, are used to construct the workspace correspondence and geometrical relationships in a surgical operation. A parametric model with a set of parameters is proposed to describe the hand-eye coordination of the surgical robot. From the results, optimal values and acceptable ranges of these parameters are identified from two tasks. A 90° viewing angle had the longest completion time; 60° instrument elevation angle and 0° deflection angle had better performance; there is no significant difference among manipulation angles and observing distances on task performance. This hand-eye coordination model provides evidence for robotic design, surgeon training, and robotic initialization to achieve dexterous and safe manipulation in surgery. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Clinical evaluation of the additive effect of diquafosol tetrasodium on sodium hyaluronate monotherapy in patients with dry eye syndrome: a prospective, randomized, multicenter study.

    Science.gov (United States)

    Kamiya, K; Nakanishi, M; Ishii, R; Kobashi, H; Igarashi, A; Sato, N; Shimizu, K

    2012-10-01

    To assess the additive effect of diquafosol tetrasodium on sodium hyaluronate monotherapy in patients with dry eye syndrome. This study evaluated 64 eyes of 32 patients (age: 62.6±12.8 years (mean±SD)) in whom treatment with 0.1% sodium hyaluronate was insufficiently responsive. The eyes were randomly assigned to one of the two regimens in each patient: topical administration of sodium hyaluronate and diquafosol tetrasodium in one eye, and that of sodium hyaluronate in the other. Before treatment, and 2 and 4 weeks after treatment, we determined tear volume, tear film break-up time (BUT), fluorescein and rose bengal vital staining scores, subjective symptoms, and adverse events. We found a significant improvement in BUT (P=0.049, Dunnett test), fluorescein and rose bengal staining scores (P=0.02), and in subjective symptoms (P=0.004 for dry eye sensation, P=0.02 for pain, and P=0.02 for foreign body sensation) 4 weeks after treatment in the diquafosol eyes. On the other hand, we found no significant change in these parameters after treatment in the control eyes. In dry eyes, where sodium hyaluronate monotherapy was insufficient, diquafosol tetrasodium was effective in improving objective and subjective symptoms, suggesting its viability as an option for the additive treatment of such eyes.

  14. Functional and morphological imaging of thyroid associated eye disease. Data evaluation by means of image fusion

    International Nuclear Information System (INIS)

    Kainz, H.

    2002-08-01

    Aim: to recognize the structures that show an uptake of a 99mTc-labeled octreotide tracer within the orbit and head in patients with thyroid associated eye disease relying on image fusion. Methods: A series of 18 patients presenting the signs and symptoms of thyroid associated eye disease were studied. Functional imaging was done with 99mTc-HYNIC-TOC, a newly in-house developed tracer. Both whole body as well as single photon emission tomographies (SPECT) of the head were obtained in each patient. Parallel to nuclear medicine imaging, morphological imaging was done using either computed tomography or magnetic resonance. Results: By means of image fusion farther more information on the functional status of the patients was obtained. All areas showing an uptake could be anatomically identified, revealing a series of organs that had not yet been consideren in this disease. The organs presenting tracer uptake showed characteristic forms as described below: - eye glass sign: lacrimal gland and lacrimal ducts - scissors sign: eye muscles, rectus sup. and inf. - arch on CT: muscle displacement - Omega sign: tonsils and salivary glands - W- sign: tonsils and salivary glands Conclusions: By means of image fusion it was possible to recognize that a series of organs of the neck and head express somatostatin receptors. We interpret these results as a sign of inflammation of the lacrimal glands, the lacrimal ducts, the cervical lymphatics, the anterior portions of the extra ocular eye muscles and muscles of the posterior cervical region. Somatostatin uptake in these sturctures reflects the prescence of specific receptors which reflect the immuno regulating function of the peptide. (author)

  15. Evaluation of pharmacological activities and assessment of intraocular penetration of an ayurvedic polyherbal eye drop (Itone™ in experimental models

    Directory of Open Access Journals (Sweden)

    Velpandian Thirumurthy

    2013-01-01

    Full Text Available Abstract Background The polyherbal eye drop (Itone™ is a mixture of aqueous distillates of nineteen traditionally used ingredients that sum up to impart potency to the formulation and make it a useful adjunct in various ocular pathologies. However, as there have been no controlled experimental studies accounting to the above claim, therefore, the present study was designed to evaluate the polyherbal formulation (PHF for antiangiogenic, anti-inflammatory, anticataract, antioxidant and cytotoxicity in addition to the evaluation of intraocular penetration of PHF in rabbit eyes using LC-MS/MS. Materials and methods Antiangiogenic activity of the PHF was evaluated using in ovo chick chorio-allantoic membrane (CAM assay and in vivo cautery induced corneal neovascularization assay in rats. Anticataract potential was evaluated using steroid induced cataract in developing chick embryos, sodium selenite induced cataract in rat pups and galactose induced cataract in rats. The antioxidant activity was evaluated using di-phenyl picryl hydrazyl (DPPH radical scavenging assay. Anti-inflammatory activity was evaluated in vitro using inhibition of LTB4 formation in human WBCs and in vivo using carrageenan induced paw edema assay in rats. The cytotoxicity was evaluated against HeLa cancer cell lines using (3-(4,5-Dimethylthiazol-2-yl-2,5-diphenyltetrazolium bromide (MTT assay. Furthermore evaluation of the intraocular penetration of the PHF was carried out in rabbit eyes via aqueous humor paracentesis and further analysis using LC-MS/MS. Results PHF significantly inhibited VEGF induced proliferation of new blood vessels in CAM assay and inhibited the cautery induced corneal neovascularization in rats. Additionally, PHF showed noticeable delay in the progression of cataract in the selenite and galactose induced cataract models whereby the PHF treated lenses were graded for stages II and III respectively. However, the PHF did not show any anticataract activity in

  16. Correlation between corneal innervation and inflammation evaluated with confocal microscopy and symptomatology in patients with dry eye syndromes: a preliminary study.

    Science.gov (United States)

    Tepelus, Tudor C; Chiu, Gloria B; Huang, Jianyan; Huang, Ping; Sadda, SriniVas R; Irvine, John; Lee, Olivia L

    2017-09-01

    To evaluate corneal innervation and inflammatory cell infiltration using in vivo confocal microscopy (IVCM) and to correlate these findings with subjective symptoms of dry eye, as measured by the Ocular Surface Disease Index (OSDI) in patients with non-Sjögren's (NSDE) and Sjögren's syndrome dry eyes (SSDE). Central corneal images were prospectively captured from 10 age-matched healthy control eyes, 24 eyes with clinically diagnosed NSDE and 44 eyes with clinically diagnosed SSDE, using IVCM (HRT III RCM). Density, tortuosity and reflectivity of corneal nerves, presence of inflammatory dendritic cells (DCs) and OSDI scores were evaluated. Images obtained by IVCM from 78 eyes were analyzed. The density of nerve fibers was 1562 ± 996 μm/frame in the SSDE group, 2150 ± 1015 μm/frame in the NSDE group and 2725 ± 687 μm/frame in the control group (P eyes affected with NSDE and SSDE are characterized by alterations in corneal innervation and infiltration of inflammatory DCs. Corneal nerve density and reflectivity are correlated with severity of subjective dry eye symptoms, as measured by OSDI score.

  17. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    Science.gov (United States)

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Sea-floor texture and physiographic zones of the inner continental shelf from Salisbury to Nahant, Massachusetts, including the Merrimack Embayment and Western Massachusetts Bay

    Science.gov (United States)

    Pendleton, Elizabeth E.; Barnhardt, Walter A.; Baldwin, Wayne E.; Foster, David S.; Schwab, William C.; Andrews, Brian D.; Ackerman, Seth D.

    2015-10-26

    A series of maps that describe the distribution and texture of sea-floor sediments and physiographic zones of Massachusetts State waters from Nahant to Salisbury, Massachusetts, including western Massachusetts Bay, have been produced by using high-resolution geophysical data (interferometric and multibeam swath bathymetry, lidar bathymetry, backscatter intensity, and seismic reflection profiles), sediment samples, and bottom photographs. These interpretations are intended to aid statewide efforts to inventory and manage coastal and marine resources, link with existing data interpretations, and provide information for research focused on coastal evolution and environmental change. Marine geologic mapping of the inner continental shelf of Massachusetts is a statewide cooperative effort of the U.S. Geological Survey and the Massachusetts Office of Coastal Zone Management.

  19. Evaluation of cyclosporine A eye penetration after administration of liposomal or conventional forms in animal model

    Directory of Open Access Journals (Sweden)

    Sara Nikoofal-Sahlabadi

    2013-01-01

    Full Text Available Abstract A lot of researches have investigated the effects of topical cyclosporine A on the eye surface layers’ diseases. By now the main limitation in cyclosporine application is the low permeation of the drug into the posterior segments of the eye. The aim of present study was to formulate high permeable dosage form can be beneficial in the topical treatment of the uveitis. To reach higher corneal drug absorption and drug concentration in the posterior segments of the eye, 3 nanoliposomal formulations containing 0.5 mg/ml cyclosporine A were prepared. Liposomal formulations and the commercial product (Restasis® were instilled in the right and left eyes of the rabbits, respectively. The rabbits were killed in the 3, 7, 14 and 28 days of study and the aqueous humor and vitreous were extracted. Mean size of liposomal formulation number 1, number 2 and number 3 were 107.2 ± 0.7, 129.3±0.9 and 144.8±1.8 nm and their zeta potential were -5.0±1.7, -5.5±2.3 and 44.6±6.2 mV, respectively. Results of ocular analysis showed that the liposomal formulations could increase the concentration of the drug in the aqueous and vitreous like Restasis®. But, in contrast with what has been expected the findings of this study implicate nanoliposomal formulations prepared could not make a significant difference in concentration of the drug in aqueous and vitreous humor compared to Restasis® (anionic microemulsion. In conclusion, we can state that liposomes with the same composition as our formulations are not more efficient than microemulsion for cyclosporine as ophthalmic drug delivery.

  20. Evaluation of Binocular Eye Trackers and Algorithms for 3D Gaze Interaction in Virtual Reality Environments

    OpenAIRE

    Thies Pfeiffer; Ipke Wachsmuth; Marc E. Latoschik

    2009-01-01

    Tracking user's visual attention is a fundamental aspect in novel human-computer interaction paradigms found in Virtual Reality. For example, multimodal interfaces or dialogue-based communications with virtual and real agents greatly benefit from the analysis of the user's visual attention as a vital source for deictic references or turn-taking signals. Current approaches to determine visual attention rely primarily on monocular eye trackers. Hence they are restricted to the interpretation of...

  1. On lamps, walls, and eyes: the spectral radiance field and the evaluation of light pollution indoors

    OpenAIRE

    Bará, Salvador; Escofet, Jaume

    2017-01-01

    Light plays a key role in the regulation of different physiological processes, through several visual and non-visual retinal phototransduction channels whose basic features are being unveiled by recent research. The growing body of evidence on the significance of these effects has sparked a renewed interest in the determination of the light field at the entrance pupil of the eye in indoor spaces. Since photic interactions are strongly wavelength-dependent, a significant effort is being devote...

  2. Flight Tasks and Metrics to Evaluate Laser Eye Protection in Flight Simulators

    Science.gov (United States)

    2017-07-07

    IFR ) IFR Instrument Flight Rules LED Light Emitting Diode LEP Laser Eye Protection MAPP Model Assessing Pilot Performance OD Optical Density...LEP and then use them to assess the impact of wearing LEP in a flight simulator environment. 2 Pending Distribution, A: Approved for public...2005). LEP has the potential to alter distinct characteristics of the visual environment, giving rise to concerns over the impact on flight tasks and

  3. Evaluation of toxicity after periocular and intravitreal administration of carboplatin in rabbit eyes

    Directory of Open Access Journals (Sweden)

    Denisa Darsová

    2011-01-01

    Full Text Available The aim of this study was to characterize the extent of toxicity of focal carboplatin administration and to identify the dose limiting toxicity in rabbit eyes depending on administered concentrations. New Zealand white male rabbits (n = 18 were treated with 1 of 3 regimens: a single periocular injection of 15 mg of carboplatin (group I, a single periocular injection of 30 mg of carboplatin (group II and a single transcorneal intravitreal injection of 0.05 mg of carboplatin (group III. Ophthalmologic examinations and vitreous samplings were performed under dissociative anaesthesia at regular intervals during next 2 (groups I and III or 3 (group II weeks. Carboplatin concentrations in vitreous samples were assessed by atomic absorption spectroscopy. At the end of experiments, all rabbit eyes were obtained for histopathologic examination. Clinical and histological evidence of toxicity was graded into four grades according to anatomical structures of the rabbit eye. The dose limiting toxicity was reached in group II after periocular injection of 30 mg of carboplatin and in group III after intravitreal injection of 0.05 mg of carboplatin. No systemic toxicity was observed in any group. Focal carboplatin administration may decrease systemic exposure to this cytotoxic drug in the retinoblastoma treatment. This moreover suggests that focal carboplatin administration is a promising approach and challenge for advanced retinoblastoma chemotherapy.

  4. The effect of arousal and eye gaze direction on trust evaluations of stranger's faces: A potential pathway to paranoid thinking.

    Science.gov (United States)

    Abbott, Jennie; Middlemiss, Megan; Bruce, Vicki; Smailes, David; Dudley, Robert

    2018-09-01

    When asked to evaluate faces of strangers, people with paranoia show a tendency to rate others as less trustworthy. The present study investigated the impact of arousal on this interpersonal bias, and whether this bias was specific to evaluations of trust or additionally affected other trait judgements. The study also examined the impact of eye gaze direction, as direct eye gaze has been shown to heighten arousal. In two experiments, non-clinical participants completed face rating tasks before and after either an arousal manipulation or control manipulation. Experiment one examined the effects of heightened arousal on judgements of trustworthiness. Experiment two examined the specificity of the bias, and the impact of gaze direction. Experiment one indicated that the arousal manipulation led to lower trustworthiness ratings. Experiment two showed that heightened arousal reduced trust evaluations of trustworthy faces, particularly trustworthy faces with averted gaze. The control group rated trustworthy faces with direct gaze as more trustworthy post-manipulation. There was some evidence that attractiveness ratings were affected similarly to the trust judgements, whereas judgements of intelligence were not affected by higher arousal. In both studies, participants reported low levels of arousal even after the manipulation and the use of a non-clinical sample limits the generalisability to clinical samples. There is a complex interplay between arousal, evaluations of trustworthiness and gaze direction. Heightened arousal influences judgements of trustworthiness, but within the context of face type and gaze direction. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Eye Protection

    OpenAIRE

    Pashby, Tom

    1986-01-01

    Eye injuries frequently occur in the home, at work and at play. Many result in legally blind eyes, and most are preventable. Awareness of potential hazards is essential to preventing eye injuries, particularly in children. In addition, protective devices must be used appropriately. We have developed eye protectors that have proved effective in reducing both the overall incidence and the severity of sports eye injuries.

  6. Reproducibility analysis of measurements with a mechanical semiautomatic eye model for evaluation of intraocular lenses

    Science.gov (United States)

    Rank, Elisabet; Traxler, Lukas; Bayer, Natascha; Reutterer, Bernd; Lux, Kirsten; Drauschke, Andreas

    2014-03-01

    Mechanical eye models are used to validate ex vivo the optical quality of intraocular lenses (IOLs). The quality measurement and test instructions for IOLs are defined in the ISO 11979-2. However, it was mentioned in literature that these test instructions could lead to inaccurate measurements in case of some modern IOL designs. Reproducibility of alignment and measurement processes are presented, performed with a semiautomatic mechanical ex vivo eye model based on optical properties published by Liou and Brennan in the scale 1:1. The cornea, the iris aperture and the IOL itself are separately changeable within the eye model. The adjustment of the IOL can be manipulated by automatic decentration and tilt of the IOL in reference to the optical axis of the whole system, which is defined by the connection line of the central point of the artificial cornea and the iris aperture. With the presented measurement setup two quality criteria are measurable: the modulation transfer function (MTF) and the Strehl ratio. First the reproducibility of the alignment process for definition of initial conditions of the lateral position and tilt in reference to the optical axis of the system is investigated. Furthermore, different IOL holders are tested related to the stable holding of the IOL. The measurement is performed by a before-after comparison of the lens position using a typical decentration and tilt tolerance analysis path. Modulation transfer function MTF and Strehl ratio S before and after this tolerance analysis are compared and requirements for lens holder construction are deduced from the presented results.

  7. The Cost-effectiveness of Welcome to Medicare Visual Acuity Screening and a Possible Alternative Welcome to Medicare Eye Evaluation Among Persons Without Diagnosed Diabetes Mellitus

    Science.gov (United States)

    Rein, David B.; Wittenborn, John S.; Zhang, Xinzhi; Hoerger, Thomas J.; Zhang, Ping; Klein, Barbara Eden Kobrin; Lee, Kris E.; Klein, Ronald; Saaddine, Jinan B.

    2013-01-01

    Objective To estimate the cost-effectiveness of visual acuity screening performed in primary care settings and of dilated eye evaluations performed by an eye care professional among new Medicare enrollees with no diagnosed eye disorders. Medicare currently reimburses visual acuity screening for new enrollees during their initial preventive primary care health check, but dilated eye evaluations may be a more cost-effective policy. Design Monte Carlo cost-effectiveness simulation model with a total of 50 000 simulated patients with demographic characteristics matched to persons 65 years of age in the US population. Results Compared with no screening policy, dilated eye evaluations increased quality-adjusted life-years (QALYs) by 0.008 (95% credible interval [CrI], 0.005–0.011) and increased costs by $94 (95% CrI, −$35 to $222). A visual acuity screening increased QALYs in less than 95% of the simulations (0.001 [95% CrI, −0.002 to 0.004) and increased total costs by $32 (95% CrI, −$97 to $159) per person. The incremental cost-effectiveness ratio of a visual acuity screening and an eye examination compared with no screening were $29 000 and $12 000 per QALY gained, respectively. At a willingness-to-pay value of $15 000 or more per QALY gained, a dilated eye evaluation was the policy option most likely to be cost-effective. Conclusions The currently recommended visual acuity screening showed limited efficacy and cost-effectiveness compared with no screening. In contrast, a new policy of reimbursement for Welcome to Medicare dilated eye evaluations was highly cost-effective. PMID:22232367

  8. Cornea and anterior eye assessment with placido-disc keratoscopy, slit scanning evaluation topography and scheimpflug imaging tomography.

    Science.gov (United States)

    Martin, Raul

    2018-03-01

    Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple and several devices and technologies allow to explore and to manage patients. The purpose of this special issue is to present and also to update in the evaluation of cornea and ocular surface and this second part, reviews a description of the corneal topography and tomography techniques, providing updated information of the clinical recommendations of these techniques in eye care practice. Placido-based topographers started an exciting anterior corneal surface analysis that allows the development of current corneal tomographers that provide a full three-dimensional reconstruction of the cornea including elevation, curvature, and pachymetry data of anterior and posterior corneal surfaces. Although, there is not an accepted reference standard technology for corneal topography description and it is not possible to determine which device produces the most accurate topographic measurements, placido-based topographers are a valuable technology to be used in primary eye care and corneal tomograhers expanding the possibilities to explore cornea and anterior eye facilitating diagnosis and follow-up in several situations, raising patient follow-up, and improving the knowledge regarding to the corneal anatomy. Main disadvantages of placido-based topographers include the absence of information about the posterior corneal surface and limited corneal surface coverage without data from the para-central and/or peripheral corneal surface. However, corneal tomographers show repeatable anterior and posterior corneal surfaces measurements, providing full corneal thickness data improving cornea, and anterior surface assessment. However, differences between devices suggest that they are not interchangeable in clinical practice.

  9. Evaluation of perception performance in neck dissection planning using eye tracking and attention landscapes

    Science.gov (United States)

    Burgert, Oliver; Örn, Veronika; Velichkovsky, Boris M.; Gessat, Michael; Joos, Markus; Strauß, Gero; Tietjen, Christian; Preim, Bernhard; Hertel, Ilka

    2007-03-01

    Neck dissection is a surgical intervention at which cervical lymph node metastases are removed. Accurate surgical planning is of high importance because wrong judgment of the situation causes severe harm for the patient. Diagnostic perception of radiological images by a surgeon is an acquired skill that can be enhanced by training and experience. To improve accuracy in detecting pathological lymph nodes by newcomers and less experienced professionals, it is essential to understand how surgical experts solve relevant visual and recognition tasks. By using eye tracking and especially the newly-developed attention landscapes visualizations, it could be determined whether visualization options, for example 3D models instead of CT data, help in increasing accuracy and speed of neck dissection planning. Thirteen ORL surgeons with different levels of expertise participated in this study. They inspected different visualizations of 3D models and original CT datasets of patients. Among others, we used scanpath analysis and attention landscapes to interpret the inspection strategies. It was possible to distinguish different patterns of visual exploratory activity. The experienced surgeons exhibited a higher concentration of attention on the limited number of areas of interest and demonstrated less saccadic eye movements indicating a better orientation.

  10. Development of criteria for evaluating clinical response in thyroid eye disease (CRI-TED) using a modified Delphi technique

    Science.gov (United States)

    Douglas, Raymond S.; Tsirbas, Angelo; Gordon, Mark; Lee, Diana; Khadavi, Nicole; Garneau, Helene Chokron; Goldberg, Robert A.; Cahill, Kenneth; Dolman, Peter J.; Elner, Victor; Feldon, Steve; Lucarelli, Mark; Uddin, Jimmy; Kazim, Michael; Smith, Terry J.; Khanna, Dinesh

    2014-01-01

    To identify components of a provisional clinical response index for thyroid eye disease (CRI-TED) using a modified Delphi technique. The International Thyroid Eye Disease Society (ITEDS) conducted a structured, 3-round Delphi exercise establishing consensus for a core set of measures for clinical trials in TED. The steering committee discussed the results in a face-to-face meeting (nominal group technique) and evaluated each criterion with respect to its feasibility, reliability, redundancy, and validity. Redundant measures were consolidated or excluded. Criteria were parsed into 11 domains for the Delphi surveys. Eighty four respondents participated in the Delphi-1 survey, providing 220 unique items. Ninety- two members (100% of the respondents from Delphi 1 plus eight new participants) responded in Delphi-2 and rated the same 220 items. Sixty-four members (76% of participants) rated 153 criteria in Delphi-3 (67 criteria were excluded due to redundancy). Criteria with a mean greater than 6 (1 least appropriate to 9 most appropriate) were further evaluated by the nominal group technique and provisional core measures were chosen. Using a Delphi exercise, we developed provisional core measures for assessing disease activity and severity in clinical trials of therapies for TED. These measures will be iteratively refined for use in multicenter clinical trials. PMID:19752424

  11. Organization of eye bank

    International Nuclear Information System (INIS)

    Reddy, S.C.

    1999-01-01

    Comeal transplantation is the only method of combating the blindness due to corneal opacity caused by infections, malnutrition, trauma and hereditary diseases. Comeal blindness is more prevalent in the developing countries. The availability of the donor cornea, trained ophthalmic surgeons and microsurgery facilities are the key factors in restoring vision in-patients with comeal blindness. The eye bank organization is somewhat similar to that of blood bank. The eye bank should be located in a hospital or a medical centre in which a laboratory may be established for the evaluation and storage of donor tissue. The medical director (Ophthalmologist), technician, secretary and public relation officer are the persons who play an important role in the successful organization of eye bank. The function of the eye bank are procurement, assessment, processing, distribution of donor eyes/corneas, training of technicians/doctors, and conducting research related to storage of donor tissue and corneal transplantation. The necessary infrastructure required for the organization of an eye bank include separate accommodation area for the personnel and the laboratory, telephone, computer, refrigerator, laminar air flow hood. Slitlamp, specular microscope, storage media and equipment, instrument for enucleation of donor eyes, and a motor vehicle. The details of responsibilities of the staff of eye bank, source of donor eyes, suitability of donor material, procurement of the donor cornea, tissue assessment, storage and preservation, distribution of donor tissue, and limitation of eye bank will be discussed at the time of presentation

  12. BEDVH--A method for evaluating biologically effective dose volume histograms: Application to eye plaque brachytherapy implants

    International Nuclear Information System (INIS)

    Gagne, Nolan L.; Leonard, Kara L.; Huber, Kathryn E.; Mignano, John E.; Duker, Jay S.; Laver, Nora V.; Rivard, Mark J.

    2012-01-01

    Purpose: A method is introduced to examine the influence of implant duration T, radionuclide, and radiobiological parameters on the biologically effective dose (BED) throughout the entire volume of regions of interest for episcleral brachytherapy using available radionuclides. This method is employed to evaluate a particular eye plaque brachytherapy implant in a radiobiological context. Methods: A reference eye geometry and 16 mm COMS eye plaque loaded with 103 Pd, 125 I, or 131 Cs sources were examined with dose distributions accounting for plaque heterogeneities. For a standardized 7 day implant, doses to 90% of the tumor volume ( TUMOR D 90 ) and 10% of the organ at risk volumes ( OAR D 10 ) were calculated. The BED equation from Dale and Jones and published α/β and μ parameters were incorporated with dose volume histograms (DVHs) for various T values such as T = 7 days (i.e., TUMOR 7 BED 10 and OAR 7 BED 10 ). By calculating BED throughout the volumes, biologically effective dose volume histograms (BEDVHs) were developed for tumor and OARs. Influence of T, radionuclide choice, and radiobiological parameters on TUMOR BEDVH and OAR BEDVH were examined. The nominal dose was scaled for shorter implants to achieve biological equivalence. Results: TUMOR D 90 values were 102, 112, and 110 Gy for 103 Pd, 125 I, and 131 Cs, respectively. Corresponding TUMOR 7 BED 10 values were 124, 140, and 138 Gy, respectively. As T decreased from 7 to 0.01 days, the isobiologically effective prescription dose decreased by a factor of three. As expected, TUMOR 7 BEDVH did not significantly change as a function of radionuclide half-life but varied by 10% due to radionuclide dose distribution. Variations in reported radiobiological parameters caused TUMOR 7 BED 10 to deviate by up to 46%. Over the range of OAR α/β values, OAR 7 BED 10 varied by up to 41%, 3.1%, and 1.4% for the lens, optic nerve, and lacrimal gland, respectively. Conclusions: BEDVH permits evaluation of the

  13. Response mode, compatibility, and dual-processes in the evaluation of simple gambles: An eye-tracking investigation

    Directory of Open Access Journals (Sweden)

    Paul Slovic

    2012-07-01

    Full Text Available We employed simple gambles to investigate information processing in relation to the compatibility effect. Subjects should be more likely to engage in a deliberative thinking strategy when completing a pricing task rather than a rating task. We used eye-tracking methodology to measure information acquisition and processing in order to test the above hypothesis as well as to show that losses and alternatives with uncertain outcomes are more likely than gains and alternatives with sure outcomes to be processed through a deliberative thinking process. Results showed that pupil dilations, fixation duration and number of fixations increased when subjects evaluated the gambles with a pricing task. Additionally, the number of fixations increased as the gamble outcome became increasingly negative and when the outcome was uncertain (vs. sure. Fixations were also predictive of subjects' final evaluations of the gambles. We discuss our results in light of the cognitive processes underlying different response modes in economic preferences.

  14. Preparation and Evaluation of Biodegradable Scleral Plug Containing Curcumin in Rabbit Eye.

    Science.gov (United States)

    Zhang, Jun; Sun, Haiyan; Zhou, Nalei; Zhang, Bin; Ma, Jingxue

    2017-12-01

    To test whether biodegradable curcumin-loaded scleral plug is a promising choice for treating posterior ocular diseases, the study investigated the in vitro release profile of the scleral plug and its safety in vivo. Scleral plugs containing 0.5 mg, 1.0 mg and 1.5 mg curcumin were synthesized by a compression-sintering method. These scleral plugs were placed in tubes containing balanced salt solution (BSS) buffer, which was replaced by fresh buffer daily. The curcumin concentration in the removed aliquot was tested daily for 14 days using high-performance liquid chromatography (HPLC). In the study, 44 rabbits were randomly divided into four groups: control, 0.5 mg, 1.0 mg and 1.5 mg curcumin groups. The scleral plug was trans-scleral fixed in the right eye of the rabbits in the three curcumin-treated groups. The control rabbits only received sclerotomy. The treated rabbit eyes were examined by a slit-lamp biomicroscope, an indirect ophthalmoscope and electroretinogram (ERG), and subjected to histological analysis. The concentration of the 1.5 mg curcumin-loaded scleral plug was higher than 15 μg/ml for consecutive 14 days in vitro. The in vivo experiments revealed intraocular pressure, a-wave and b-wave amplitudes of ERG, and conjunctival reaction degree were not significantly different between the four groups. Retinal structure was normal in the curcumin-treated groups. The sclerotomy wound healed after the plug was completely degraded. Anterior chamber reaction or complications were not observed. The study suggests that curcumin-loaded scleral plug could sustain high concentration of curcumin in vitro and is safe in vivo. It might be a promising alternative choice for the treatment of posterior ocular diseases.

  15. Evaluation of patients with dry eye disease for conjunctival Chlamydia trachomatis and Ureaplasma urealyticum.

    Science.gov (United States)

    Abdelfattah, Maha Mohssen; Khattab, Rania Abdelmonem; Mahran, Magda H; Elborgy, Ebrahim S

    2016-01-01

    To determine the possibility of the development of dry eye disease (DED) as a result of persistent infection with Chlamydia trachomatis and Ureaplasma urealyticum in the conjunctiva of patients. This study was conducted on 58 patients of age range 20-50y, diagnosed with DED confirmed by Schirmer I test and tear breakup time. The non-dry eye control group included 27 subjects of the same age. Ocular specimens were collected as conjunctival scrapings and swabs divided into three groups: the first used for bacterial culture, the second and third taken to detect Chlamydia trachomatis and Ureaplasma urealyticum by direct fluorescent antibody (DFA) assay and polymerase chain reaction (PCR) method. Chlamydia trachomatis was detected in 65.5% and 76% of DED patients by DFA and PCR methods respectively. Ureaplasma urealyticum was found in 44.8% of DED infected patients using the PCR method. Both organisms were identified in only 37.9% of DED patients found to be infected. Control subjects had a 22% detection rate of Chlamydia trachomatis by DFA assay versus a 7% detection rate by PCR; while Ureaplasma urealyticum was detected in 3.7% of the controls by PCR method. The conjunctival culture revealed that gram positive microorganisms represented 75% of isolates with coagulase negative Staphylococci the most common (50%) followed by Staphylococcus aureus (20%), whereas gram negative microorganisms occurred in 25% of cases, isolating Moraxella spp. as the most frequent organism. Our results tend to point out that Chlamydia trachomatis and Ureaplasma urealyticum were detected in a moderate percentage of patients with DED, and could be a fair possibility for its development. PCR is more reliable in detecting Chlamydia trachomatis than DFA technique. The presence of isolated conjunctival bacterial microflora can be of some potential value.

  16. Eye Cancer

    Science.gov (United States)

    Cancer of the eye is uncommon. It can affect the outer parts of the eye, such as the eyelid, which are made up ... and nerves. If the cancer starts inside the eyeball it's called intraocular cancer. The most common intraocular ...

  17. Black Eye

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  18. Eye Anatomy

    Science.gov (United States)

    ... News About Us Donate In This Section Eye Anatomy en Español email Send this article to a ... You at Risk For Glaucoma? Childhood Glaucoma Eye Anatomy Five Common Glaucoma Tests Glaucoma Facts and Stats ...

  19. Eye Emergencies

    Science.gov (United States)

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Eye Emergencies Lung Emergencies Surgeries Eye Emergencies Marfan syndrome significantly increases your risk of retinal detachment, a ...

  20. Your Eyes

    Science.gov (United States)

    ... away? If you guessed the eye, you're right! Your eyes are at work from the moment you wake up to the ... the eye is seeing. A Muscle Makes It Work The lens is suspended in ... of the lens. That's right — the lens actually changes shape right inside your ...

  1. The effect of gender on eye colour variation in European populations and an evaluation of the IrisPlex prediction model.

    Science.gov (United States)

    Pietroni, Carlotta; Andersen, Jeppe D; Johansen, Peter; Andersen, Mikkel M; Harder, Stine; Paulsen, Rasmus; Børsting, Claus; Morling, Niels

    2014-07-01

    In two recent studies of Spanish individuals, gender was suggested as a factor that contributes to human eye colour variation. However, gender did not improve the predictive accuracy on blue, intermediate and brown eye colours when gender was included in the IrisPlex model. In this study, we investigate the role of gender as a factor that contributes to eye colour variation and suggest that the gender effect on eye colour is population specific. A total of 230 Italian individuals were typed for the six IrisPlex SNPs (rs12913832, rs1800407, rs12896399, rs1393350, rs16891982 and rs12203592). A quantitative eye colour score (Pixel Index of the Eye: PIE-score) was calculated based on digital eye images using the custom made DIAT software. The results were compared with those of Danish and Swedish population samples. As expected, we found HERC2 rs12913832 as the main predictor of human eye colour independently of ancestry. Furthermore, we found gender to be significantly associated with quantitative eye colour measurements in the Italian population sample. We found that the association was statistically significant only among Italian individuals typed as heterozygote GA for HERC2 rs12913832. Interestingly, we did not observe the same association in the Danish and Swedish population. This indicated that the gender effect on eye colour is population specific. We estimated the effect of gender on quantitative eye colour in the Italian population sample to be 4.9%. Among gender and the IrisPlex SNPs, gender ranked as the second most important predictor of human eye colour variation in Italians after HERC2 rs12913832. We, furthermore, tested the five lower ranked IrisPlex predictors, and evaluated all possible 3(6) (729) genotype combinations of the IrisPlex assay and their corresponding predictive values using the IrisPlex prediction model [4]. The results suggested that maximum three (rs12913832, rs1800407, rs16891982) of the six IrisPlex SNPs are useful in practical

  2. Evaluation of 10 AMD Associated Polymorphisms as a Cause of Choroidal Neovascularization in Highly Myopic Eyes.

    Directory of Open Access Journals (Sweden)

    Alvaro Velazquez-Villoria

    Full Text Available Choroidal neovascularization (CNV commonly occurs in age related macular degeneration and pathological myopia patients. In this study we conducted a case-control prospective study including 431 participants. The aim of this study was to determine the potential association between 10 single nucleotide polymorphisms (SNPs located in 4 different genetic regions (CFI, COL8A1, LIPC, and APOE, and choroidal neovascularization in age-related macular degeneration and the development of choroidal neovascularization in highly myopic eyes of a Caucasian population. Univariate and multivariate logistic regression analysis adjusted for age, sex and hypertension was performed for each allele, genotype and haplotype frequency analysis. We found that in the univariate analysis that both single-nucleotide polymorphisms in COL8A1 gene (rs13095226 and rs669676 together with age, sex and hypertension were significantly associated with myopic CNV development in Spanish patients (p0.05; however, analysis of the axial length between genotypes of rs13095226 revealed an important influence of COL8A1 in the development of CNV in high myopia. Furthermore we conducted a meta-analysis of COL8A1, CFI and LIPC genes SNPs (rs669676, rs10033900 and rs10468017 and found that only rs669676 of these SNPs were associated with high myopia neovascularization.

  3. Evaluating the potential of GeoEye data in retrieving LAI at watershed scale

    Science.gov (United States)

    Aquilino, Mariella; Novelli, Antonio; Tarantino, Eufemia; Iacobellis, Vito; Gentile, Francesco

    2014-10-01

    LAI is defined as one sided green leaf area per unit ground area in broadleaf canopies and is an important input parameter to monitor crop growth conditions and to improve the performance of crop yield models. Because direct measurements of LAI are usually time-consuming and require continuous updates, remote sensing is an alternative to estimate this attribute over large areas as watershed scale. The primary objective of this work was to derive a reliable LAI estimation model from VHR satellite data to be compared with moderate resolution satellite products in order to improve LAI estimation performance for next validation activities. Due to lack of contemporaneous satellite and on-site sensor data acquisitions and intrinsic complexity of physical models, in our study case the semi-empirical approach with the CLAIR model was applied. It is based on an inverse exponential relationship between LAI and the WDVI (Weighted Difference Vegetation Index) related to different land covers. LAI values were generated from multispectral GeoEye-1 sensor data covering a time space of 5 years (2009-2013) to study crop phenological stages on the study area of the Carapelle watershed located in the North of Puglia region (Southern Italy). Data were preliminarily pre-processed (geometric and radiometric correction), classified (ISODATA method) and texture based analyzed in order to extract the vegetated areas (mainly cereal crops). Finally, the resulted maps were compared with moderate resolution satellite data by reaching a possible correspondence.

  4. Eye and orbit ultrasound

    Science.gov (United States)

    ... Images Head and eye echoencephalogram References Coleman DJ, Silverman RH, Lloyd HO, Daly S. Evaluation of the posterior ... Vision Institute, La Jolla, CA. Also reviewed by David Zieve, MD, MHA, Medical Director, Brenda Conaway, Editorial ...

  5. Safety and comfort evaluation of a new formulation of Visine® lubricant eye drops containing HydroBlend™ and GentlePur™

    Directory of Open Access Journals (Sweden)

    Torkildsen G

    2016-02-01

    Full Text Available Gail Torkildsen,1 Sherryl Frisch,2 Mingqi Bai,2 Louis Gentner III,2 Uday Doshi,2 Jane Zhang2 1Andover Eye Associates, Andover, MA, USA; 2Johnson & Johnson Consumer and Personal Products Worldwide, Division of Johnson & Johnson Consumer Companies, Inc, Morris Plains, NJ, USA Purpose: To evaluate the clinical safety and comfort of a new benzalkonium chloride-free Visine® lubricant eye drop formulation (Hydroblend™ and GentlePur™ in healthy and dry eye subjects.Methods: This was a single-site, open-label clinical study comprised of 22 healthy and 22 dry eye subjects. Subjects were instructed to instill 1–2 drops of the test product four times a day for 2 weeks and were examined at visit 1 (day 0, visit 2 (day 7, and visit 3 (day 14. Assessments at each visit included postdosing product usage comfort scores, predosing fluorescein corneal staining score, predosing visual acuity, and pre- and postdosing ocular structure change using slit-lamp biomicroscopy. Adverse events were monitored throughout the course of the study.Results: Throughout the 14 days of the trial period, subjects from both healthy and dry eye groups rated the eye drops as “very comfortable”. For dry eye group, the mean product usage comfort scores for the first 3 minutes postdosing ranged from 8.5 to 8.8 at visit 1 and 9.2 to 9.6 at visit 3 on a 0–10 point scale, with 0 being very uncomfortable and 10 being very comfortable. The mean corneal staining scores over five corneal regions changed from 0.65 at visit 1 to 0.39 at visit 3 for dry eye group. The individual region corneal staining scores were also decreased from visits 1 to 3 for dry eye group. All subjects maintained pretreatment means visual acuity at visits 2 and 3. Biomicroscopic examination indicated no structural changes at all visits. There were no significant adverse events reported during the course of the study.Conclusion: The study confirms that GentlePur™ is an appropriate choice as a preservative

  6. Evaluation of Two Systems for Fundus-Controlled Scotopic and Mesopic Perimetry in Eye with Age-Related Macular Degeneration.

    Science.gov (United States)

    Steinberg, Julia S; Saßmannshausen, Marlene; Pfau, Maximilian; Fleckenstein, Monika; Finger, Robert P; Holz, Frank G; Schmitz-Valckenberg, Steffen

    2017-07-01

    The purpose of this study was to evaluate and compare the MP-1S (Nidek Technologies, Padova, Italy) and the S-MAIA (CenterVue, Padova, Italy) for mesopic and scotopic fundus-controlled perimetry (FCP) in age-related macular degeneration (AMD). Eleven eyes from 11 patients underwent mesopic and, after 30 minutes of dark adaptation, scotopic (MP-1S: Goldmann V, 200 ms, background luminance 0.0032 cd/m 2 ; S-MAIA: Goldman III, 200 ms, background luminance grid of 56 stimulus points covering 16° of the central macula was used. Examination time, fixation stability, and threshold values were analyzed. The upper end of the dynamic range (≤4 dB of lowest threshold) was frequently reached by the MP-1S for mesopic testing (median 34 of 56 stimuli), while threshold values within the lower 4 dB of the dynamic range were occasionally found with the S-MAIA for scotopic testing (median 3 for cyan, median 2 for red). After correction of the stimulus intensity for the S-MAIA results, the median difference for all stimuli between both devices for mesopic testing was -2.0 dB (interquartile range [-4;0], range -14 to 6). The results indicate that robust testing of mesopic and scotopic function is feasible with both devices in patients with AMD, although both devices are susceptible to floor and ceiling effects. The interpretation and particularly the comparison of both scotopic and mesopic FCP results between the MP-1S and the S-MAIA in AMD eyes need to consider variable susceptibility of floor and ceiling effects. Further software updates are desirable as FCP captures visual functional loss that is not noted with best-corrected central visual acuity and is important for clinical trials in AMD.

  7. Efficacy of topical cyclosporine 0.05% eye drops in the treatment of dry eyes

    OpenAIRE

    Haitham Y Al-Nashar

    2015-01-01

    Purpose The aim of the present study was to evaluate the effectiveness of cyclosporine 0.05% in the treatment of dry-eye disease. Patients and methods A total of 35 eyes of 20 patients with dry-eye disease were included in the present study. Ten patients (20 eyes) had dry eyes associated with systemic rheumatologic disease (Sjögren′s syndrome), five patients (10 eyes) had dry eyes after undergoing laser in-situ keratomileusis, and five patients (five eyes) had dry eyes after cataract...

  8. Diabetes eye exams

    Science.gov (United States)

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... if the doctor who takes care of your diabetes checks your eyes, you need an eye exam ...

  9. Radiobiology for eye plaque brachytherapy and evaluation of implant duration and radionuclide choice using an objective function

    International Nuclear Information System (INIS)

    Gagne, Nolan L.; Leonard, Kara L.; Rivard, Mark J.

    2012-01-01

    Purpose: Clinical optimization of Collaborative Ocular Melanoma Study (COMS) eye plaque brachytherapy is currently limited to tumor coverage, consensus prescription dosage, and dose calculations to ocular structures. The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide R and implant duration T. This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position P, prescription dose, R, and T. Methods: Plaque-heterogeneity-corrected dose distributions were generated with MCNP5 for the range of currently available COMS plaques loaded with sources using three available low-energy radionuclides. These physical dose distributions were imported into the PINNACLE 3 treatment planning system using the TG-43 hybrid technique and used to generate dose volume histograms for a T = 7 day implant within a reference eye geometry including the ciliary body, cornea, eyelid, foveola, lacrimal gland, lens, optic disc, optic nerve, retina, and tumor at eight standard treatment positions. The equation of Dale and Jones was employed to create biologically effective dose volume histograms (BEDVHs), allowing for BED volumetric analysis of all ROIs. Isobiologically effective prescription doses were calculated for T = 5 days down to 0.01 days, with BEDVHs subsequently generated for all ROIs using correspondingly reduced prescription doses. Objective functions were created to evaluate the BEDVHs as a function of R and T. These objective functions are mathematically accessible and sufficiently general to be applied to temporary or permanent brachytherapy implants for a variety of disease sites. Results: Reducing T from 7 to 0.01 days for a 10 mm plaque produced an average BED benefit of 26%, 20%, and 17% for 103 Pd, 125 I, and 131 Cs, respectively, for all P; 16 and 22 mm plaque results were more position-dependent. 103 Pd produced a 16%–35% BED benefit over

  10. Through the Eyes of the User: Evaluating Neonatal Intensive Care Unit Design.

    Science.gov (United States)

    Denham, Megan E; Bushehri, Yousef; Lim, Lisa

    2018-01-01

    This article presents a pilot study that employed a user-centered methodology for evaluating and quantifying neonatal intensive care unit (NICU) designs based on the needs of the primary users. The design of NICUs has begun to shift from open-bay to single-family rooms. Both designs present unique advantages and challenges that impact babies, families, and caregivers. One NICU design was analyzed using the functional scenario (FS) analysis method. For the FS, users' needs were determined through literature review, interviews with NICU providers and parents, and a review of published design guidelines. Quantitative metrics were developed for each FS, so that characteristics of the NICU design could be analyzed to determine how successful they were in meeting the users' needs. The results were graphically represented to visualize the success and considerations of the design. A total of 23 FSs and 61 spatial metrics were developed. FSs for babies focused on infection prevention, minimizing exposure to environmental stimuli, and supporting enriching care activities. FSs for family members focused on direct access to the baby, and privacy and adequate space for daily activities. FSs for providers and caregivers focused on infection prevention, care activities, care zones, and visibility. Using an FS approach highlights design characteristics in the NICU that need to be addressed during the design process to more successfully meet the needs of the different users. Additionally, using this approach can inform design professionals' decision-making by presenting them with the design characteristics that impact the needs of the user groups.

  11. Eye movement dysfunction in first-degree relatives of patients with schizophrenia: a meta-analytic evaluation of candidate endophenotypes.

    Science.gov (United States)

    Calkins, Monica E; Iacono, William G; Ones, Deniz S

    2008-12-01

    Several forms of eye movement dysfunction (EMD) are regarded as promising candidate endophenotypes of schizophrenia. Discrepancies in individual study results have led to inconsistent conclusions regarding particular aspects of EMD in relatives of schizophrenia patients. To quantitatively evaluate and compare the candidacy of smooth pursuit, saccade and fixation deficits in first-degree biological relatives, we conducted a set of meta-analytic investigations. Among 18 measures of EMD, memory-guided saccade accuracy and error rate, global smooth pursuit dysfunction, intrusive saccades during fixation, antisaccade error rate and smooth pursuit closed-loop gain emerged as best differentiating relatives from controls (standardized mean differences ranged from .46 to .66), with no significant differences among these measures. Anticipatory saccades, but no other smooth pursuit component measures were also increased in relatives. Visually-guided reflexive saccades were largely normal. Moderator analyses examining design characteristics revealed few variables affecting the magnitude of the meta-analytically observed effects. Moderate effect sizes of relatives v. controls in selective aspects of EMD supports their endophenotype potential. Future work should focus on facilitating endophenotype utility through attention to heterogeneity of EMD performance, relationships among forms of EMD, and application in molecular genetics studies.

  12. PERSIST: Physician's Evaluation of Restasis® Satisfaction in Second Trial of topical cyclosporine ophthalmic emulsion 0.05% for dry eye: a retrospective review

    Directory of Open Access Journals (Sweden)

    Mah F

    2012-11-01

    Full Text Available Francis Mah,1 Mark Milner,2 Samuel Yiu,3 Eric Donnenfeld,4 Taryn M Conway,5 David A Hollander51University of Pittsburgh, Pittsburgh, PA, 2The Eye Center, Hamden, CT, 3University of Southern California, Los Angeles, CA, 4Ophthalmic Consultants of Long Island and Connecticut, Rockville Centre, New York, NY, 5Allergan Inc, Irvine, CA, USABackground: Chronic dry eye disease often requires long-term therapy. Tear film alterations in the setting of dry eye may include reduced tear volume as well as an increase in inflammatory cytokines and osmolarity. Topical cyclosporine ophthalmic emulsion 0.05% (Restasis®; Allergan Inc, Irvine, CA is indicated to increase tear production in patients with dry eye and reduced tear production presumed to be due to ocular inflammation. This study was designed to evaluate the efficacy of a second trial of topical cyclosporine in patients with dry eye who were previously considered treatment failures.Materials and methods: This multicenter (three cornea practices retrospective chart review evaluated clinical outcomes in patients with dry eye who received a second trial of cyclosporine after a prior treatment failure, defined as prior discontinuation of topical cyclosporine after less than 12 weeks.Results: Thirty-five patients, most of whom were female (71.4% and Caucasian (62.9%, were identified. Prior discontinuation was most commonly due to burning/stinging (60%. The median duration of second treatment was 10 months (range 1 week to 45 months. Physician education was provided in the second trial in 97.1% of cases. At initiation of the second trial of cyclosporine, 10 (28.6% patients received courses of topical corticosteroids. Physicians reported on a questionnaire that 80% of patients achieved clinical benefit with a second trial of cyclosporine.Conclusion: A repeat trial with topical cyclosporine can achieve clinical success. Direct patient education via the physician and staff may be key to success. Proper patient

  13. Eye Injuries

    Science.gov (United States)

    ... that you could lose your vision. Most eye injuries are preventable. If you play sports or work in certain jobs, you may need protection. The most common type of injury happens when something irritates the ...

  14. Eyes - bulging

    Science.gov (United States)

    ... different ages. In: Lambert SR, Lyons CJ, eds. Taylor and Hoyt's Pediatric Ophthalmology and Strabismus . 5th ed. Philadelphia, PA: Elsevier; 2017:chap 96. Orge FH, Grigorian F. Examination and common problems of the neonatal eye. ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Stories Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? ...

  17. Serologic Evaluation of Cornea Donors and Microbiologic Evaluation of Cornea Storage Media in an Eye Bank from Izmir, Turkey.

    Science.gov (United States)

    Palamar, Melis; Degirmenci, Cumali; Sertoz, Ruchan; Aydemir, Sohret; Egrilmez, Sait; Yagci, Ayse

    2017-12-01

    Our objective was to evaluate the serologic positivity of cornea donors and microbiologic positivity of cornea storage media at the Ege University Tissue and Cornea Bank, Izmir, Turkey. We retrospectively investigated the serologic blood sample and microbiological culture media analysis results of all cornea donors at Ege University Tissue and Cornea Bank between 2007 and 2015 with reference to age, sex, and cause of death of each donor. Mean age of the 955 deceased donors was 43.19 ± 15.89 years (range, 2-65 y). The mean postmortem time to blood sample removal and excision of the cornea tissue was 8.4 hours (range, 4-12 h). Serologic analyses showed that 855 donors (89.5%) were seronegative. The remaining donors were seropositive for hepatitis B (54 donors; 5.7%), human immunodeficiency (27 donors; 2.8%), hepatitis C (14 donors; 1.5%), and syphilis (5 donors; 0.5%) virus infections. Microbiologic analyses of the storage media were negative, with no microorganisms shown in 855 samples (89.5%). Candida species (32 donors; 3.4%), Escherichia coli (14 donors; 1.5%), Pseudomonas aeruginosa (11 donors; 1.2%), methicillin-resistant Staphylococcus aureus (11 donors; 1.2%), Enterobacter species (11 donors; 1.2%), Klebsiella pneumoniae (7 donors; 0.7%), Acinetobacter baumannii (6 donors; 0.6%), Proteus species (5 donors; 0.5%), and Corynebacterium species (3 donors; 0.3%) were the detected microorganisms in the infected storage media. False-positive serologic results among cornea donors were high. The incidence of false-positive results might be decreased by earlier blood removal from deceased donors and testing of all potential donors in intensive care units. Although rare, endophthalmitis after keratoplasty might be a devastating problem. In addition to serologic testing, microbiologic analyses of cornea storage media before transplant may be an effective way to prevent postoperative infectious complications.

  18. Evaluation of a Public Child Eye Health Tertiary Facility for Pediatric Cataract in Southern Nigeria I: Visual Acuity Outcome

    Science.gov (United States)

    Duke, Roseline E.; Adio, Adedayo; Oparah, Sidney K.; Odey, Friday; Eyo, Okon A.

    2016-01-01

    Purpose: A retrospective study of the outcome of congenital and developmental cataract surgery was conducted in a public child eye health tertiary facility in children <16 years of age in Southern Nigeria, as part of an evaluation. Materials and Method: Manual Small Incision Cataract Surgery with or without anterior vitrectomy was performed. The outcome measures were visual acuity (VA) and change (gain) in visual acuity. The age of the child at onset, duration of delay in presentation, ocular co-morbidity, non ocular co-morbidity, gender, and pre operative visual acuity were matched with postoperative visual acuity. A total of 66 children were studied for a period of six weeks following surgery. Results: Forty eight (72.7%) children had bilateral congenital cataracts and 18 (27.3%) children had bilateral developmental cataracts. There were 38(57.6%) males and 28 (42.4%) females in the study. Thirty Five (53%) children had good visual outcome (normal vision range 6/6/ -6/18) post-operatively. The number of children with blindness (vision <3/60) decreased from 61 (92.4%) pre-operatively to 4 (6.1%) post-operatively. Post operative complication occurred in 6.8% of cases six week after surgery. Delayed presentation had an inverse relationship with change (gain) in visual acuity (r = - 0.342; p-value = 0.005). Pre-operative visual acuity had a positive relationship with post operative change (gain) in visual acuity (r = 0.618; p-value = 0.000). Conclusion: Predictors of change in visual acuity in our study were; delayed presentation and pre-operative VA. Cataract surgery in children showed clinical benefit. PMID:27347247

  19. Evaluation of Visual Field Test Parameters after Artificial Tear Administration in Patients with Glaucoma and Dry Eye.

    Science.gov (United States)

    Özyol, Pelin; Özyol, Erhan; Karalezli, Aylin

    2018-01-01

    To examine the effect of a single dose of artificial tear administration on automated visual field (VF) testing in patients with glaucoma and dry eye syndrome. A total of 35 patients with primary open-angle glaucoma experienced in VF testing with symptoms of dry eye were enrolled in this study. At the first visit, standard VF testing was performed. At the second and third visits with an interval of one week, while the left eyes served as control, one drop of artificial tear was administered to each patient's right eye, and then VF testing was performed again. The reliability parameters, VF indices, number of depressed points at probability levels of pattern deviation plots, and test times were compared between visits. No significant difference was observed in any VF testing parameters of control eyes (P>0.05). In artificial tear administered eyes, significant improvement was observed in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2) of pattern deviation plots (P˂0.05). The post-hoc test revealed that artificial tear administration elicited an improvement in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2%) of pattern deviation plots from first visit to second and third visits (P˂0.01, for all comparisons). The intraclass correlation coefficient for the three VF test indices was found to be between 0.735 and 0.85 (P<0.001, for all). A single dose of artificial tear administration immediately before VF testing seems to improve test results and decrease test time.

  20. Comparative Evaluation of Silicone Hydrogel Contact Lenses and Autologous Serum for Management of Sjögren Syndrome-Associated Dry Eye.

    Science.gov (United States)

    Li, Jinyang; Zhang, Xiahua; Zheng, Qinxiang; Zhu, Yirui; Wang, Hui; Ma, Huixiang; Jhanji, Vishal; Chen, Wei

    2015-09-01

    To comparatively evaluate the efficacy of a bandage contact lens (BCL) and autologous serum (AS) eye drops in the management of severe dry eye caused by Sjögren syndrome (SS). In this prospective randomized study, 40 patients with SS were enrolled. Patients were divided into 2 treatment groups: BCL and AS. A total of 37 patients were included, 18 patients (35 eyes) in the AS group and 19 patients (36 eyes) in the BCL group. At the end of 6 weeks, the best-corrected visual acuity improved significantly in the BCL group (0.5 ± 0.3 vs. 0.3 ± 0.2, P = 0.003) but not in the AS group (0.4 ± 0.3 vs. 0.3 ± 0.3, P = 0.11). The best-corrected visual acuity remained stable up to 6 weeks after discontinuation of the BCL (0.5 ± 0.3 vs. 0.4 ± 0.2, P = 0.03). Although the Ocular Surface Disease Index scores decreased significantly after treatment in both groups, patients in the BCL group had lower Ocular Surface Disease Index scores than those in the AS group (53.4 vs. 41.8 at week 3, 47.1 vs. 31.0 at week 6, 52.7 vs. 32.0 at week 12; P = 0.014, dry eye. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT02147509.

  1. Histopathologic evaluation of the anterior segment of eyes enucleated due to glaucoma secondary to primary lens displacement in 13 canine globes.

    Science.gov (United States)

    Alario, Anthony F; Pizzirani, Stefano; Pirie, Christopher G

    2013-07-01

    PURPOSE  To describe histologic anterior segment changes in eyes affected with primary lens displacement (PLD) and secondary glaucoma. METHODS  Histologic sections stained with H&E from canine eyes enucleated because of PLD and secondary glaucoma were examined. RESULTS  Thirteen eyes from 12 patients were evaluated. Four dogs were castrated males and eight spayed females. Median age was 8 years of age (range 3-13). Breeds included seven terriers and five other breeds. All eyes examined demonstrated varying degrees of inflammation involving the iris and cleft. Mononuclear and melanophagic infiltration of the cleft was found in all specimens. Four globes also showed polymorphonuclear infiltrate. Pre-iridal fibrovascular membranes were clearly identified in 10 of 13 eyes. Total inflammatory score was significantly greater in all globes examined compared with an age-matched group of normal dogs. The posterior pigmented iris epithelium demonstrated a consistent pattern of hyperplasia and/or hypertrophy and cystic degeneration, more prominent in the more central regions. In some cases, hyperplasia was of greatest severity in the mid-iris and associated with thinning or flattening of the pupillary region. CONCLUSIONS  These results suggest that lens instability may be associated with chronic inflammation and secondary glaucoma. Mechanical irritation from an unstable lens may result in hypertrophy and/or hyperplasia of the posterior pigmented iris epithelium and subsequent cellular exfoliation and release of melanin. An inflammatory reaction directly or indirectly related to melanin release may obstruct the outflow pathways ultimately leading to glaucoma and loss of vision. Use of topical steroids may be warranted in dogs with PLD. © 2012 American College of Veterinary Ophthalmologists.

  2. Evaluation of the shifting of the line of sight and higher order aberrations of eyes with keratoconus after corneal cross-linking.

    Science.gov (United States)

    Kosekahya, Pinar; Koc, Mustafa; Tekin, Kemal; Uzel, Murat; Atilgan, Cemile Ucgul; Caglayan, Mehtap; Yilmazbas, Pelin

    2017-10-01

    To evaluate changes in the coordinates of the line of sight (LoS) and higher order aberrations (HOAs) of eyes with keratoconus, following corneal cross-linking (CXL). All patients (93 eyes) underwent detailed ophthalmologic examination and Pentacam HR measurements at baseline and at 3, 6, and 12 months after corneal CXL. LoS coordinates on the horizontal (x) and vertical (y) axes, vertical coma, vertical trefoil, spherical aberration, total root-mean square (RMS), and HOA-RMS values were recorded along with visual acuity and topographical parameters. LoS significantly shifted to the nasal region after corneal CXL in both right and left eyes (p=0.003 and p=0.01, respectively). Horizontal axis values of both eyes significantly shifted to the temporal region at postoperative 6th months compared to the baseline measurements (p=0.02 and p=0.02, respectively) and remained the same between postoperative 6th months and 12th months (p=1.00 and p=0.97, respectively). Total-RMS, HOA-RMS, vertical coma, and spherical aberration values significantly improved after corneal CXL (pbaseline measurements (p=0.003, p=0.02, p0.05 for all values). The changes in horizontal-axis coordinates in left eyes were significantly correlated with anterior elevation, anterior astigmatism, total-RMS and HOA-RMS changes (r 2 =0.20, p=0.03; r 2 =0.35, pshifted to the nasal region and HOAs improved after corneal CXL and these changes stabilized 6th months after corneal CXL. It would be more better to perform refractive surgery in crosslinked corneas at least 6th months after corneal CXL. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  3. An evaluation of Retaine™ ophthalmic emulsion in the management of tear film stability and ocular surface staining in patients diagnosed with dry eye

    Directory of Open Access Journals (Sweden)

    Ousler III G

    2015-02-01

    Full Text Available George Ousler III,1 Douglas K Devries,2 Paul M Karpecki,3 Joseph B Ciolino41Ora, Inc, Andover, MA, USA; 2Eye Care Associates of Nevada, Sparks, NV, USA; 3Koffler Vision Group, Lexington, KY, USA; 4Massachusetts Eye and Ear, Boston, MA, USAAbstract: A single-center, open-label study consisting of two visits over the course of approximately 2 weeks was conducted to evaluate the efficacy of Retaine™ ophthalmic emulsion in improving the signs and symptoms of dry eye. Forty-two subjects were enrolled and received 1–2 drops twice daily of Retaine™ beginning at the first visit (day 1 and ending at the second visit. Subjects were instructed to complete a symptomatology diary twice daily prior to drop instillation through the morning of the second visit. Ocular sign and symptom assessments, visual acuity procedures, and comfort assessments were conducted during both visits. A statistically significant reduction was observed in mean breakup area on the second visit between the predose time and the postdose time (P=0.026. On the second visit, subjects had significantly less corneal fluorescein staining in the superior (P=0.002, central (P=0.017, corneal sum (P=0.011, and all ocular regions combined (P=0.038 than on the first visit. On the second visit, statistically significant reductions in dryness (P<0.001, grittiness (P=0.0217, ocular discomfort (P=0.0017, and all symptoms (P<0.001 were also seen as measured by the Ora Calibra™ Ocular Discomfort and 4-Symptom Questionnaire (0–5 scale. Subjects reported a statistically significant improvement in their abilities to work with a computer at night (P=0.044. Mean drop comfort scores ranged from 1.29–1.81 on the Ora Calibra™ 0–10 Drop Comfort Scale, on which 0 is very comfortable and 10 is very uncomfortable. Retaine™ demonstrates promising results as a novel artificial tear option for individuals suffering from dry eye. The unique mechanism of action of Retaine™ provides enhanced comfort

  4. Evaluation of Optical Quality: Ocular Scattering and Aberrations in Eyes Implanted with Diffractive Multifocal or Monofocal Intraocular Lenses.

    Science.gov (United States)

    Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun

    2018-06-01

    To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.

  5. Eye tracking for visual marketing

    NARCIS (Netherlands)

    Wedel, M.; Pieters, R.

    2008-01-01

    We provide the theory of visual attention and eye-movements that serves as a basis for evaluating eye-tracking research and for discussing salient and emerging issues in visual marketing. Motivated from its rising importance in marketing practice and its potential for theoretical contribution, we

  6. Eye emergencies

    Science.gov (United States)

    ... eye can be caused by a work-related accident. It can also be caused by common household ... hammers, or other striking tools Working with toxic chemicals Cycling or when in windy and ... A.D.A.M.'s editorial policy , editorial process and privacy policy . A.D.A.M. is ...

  7. Eye Cancer

    Science.gov (United States)

    ... layer of tissue underneath the retina that contains connective tissue and melanocytes, which are pigmented (colored) cells, and nourishes the inside of the eye. The choroid is the most common site for a tumor. Types of intraocular cancer The most common intraocular cancer in adults is ...

  8. Eye trauma

    African Journals Online (AJOL)

    2011-02-02

    Feb 2, 2011 ... Note your findings in an orderly fashion: orbit, lids, conjunctiva, cornea, anterior chamber, iris, pupil reaction, lens, fundus. • Stain cornea with fluorescein. It is advisable to examine the eye as soon as possible since a delay will invariably lead to lid swelling, making the examination far more difficult. This can ...

  9. Are ultrasound-guided ophthalmic blocks injurious to the eye? A comparative rabbit model study of two ultrasound devices evaluating intraorbital thermal and structural changes.

    Science.gov (United States)

    Palte, Howard D; Gayer, Steven; Arrieta, Esdras; Scot Shaw, Eric; Nose, Izuru; Lee, Elizabete; Arheart, Kristopher L; Dubovy, Sander; Birnbach, David J; Parel, Jean-Marie

    2012-07-01

    Since Atkinson's original description of retrobulbar block in 1936, needle-based anesthetic techniques have become integral to ophthalmic anesthesia. These techniques are unfortunately associated with rare, grave complications such as globe perforation. Ultrasound has gained widespread acceptance for peripheral nerve blockade, but its translation to ocular anesthesia has been hampered because sonic energy, in the guise of thermal or biomechanical insult, is potentially injurious to vulnerable eye tissue. The US Food and Drug Administration (FDA) has defined guidelines for safe use of ultrasound for ophthalmic examination, but most ultrasound devices used by anesthesiologists are not FDA-approved for ocular application because they generate excessive energy. Regulating agencies state that ultrasound examinations can be safely undertaken as long as tissue temperatures do not increase >1.5°C above physiological levels. Using a rabbit model, we investigated the thermal and mechanical ocular effects after prolonged ultrasonic exposure to single orbital- and nonorbital-rated devices. In a dual-phase study, aimed at detecting ocular injury, the eyes of 8 rabbits were exposed to continuous 10-minute ultrasound examinations from 2 devices: (1) the Sonosite Micromaxx (nonorbital rated) and (2) the Sonomed VuMax (orbital rated) machines. In phase I, temperatures were continuously monitored via thermocouples implanted within specific eye structures (n = 4). In phase II the eyes were subjected to ultrasonic exposure without surgical intervention (n = 4). All eyes underwent light microscopy examinations, followed at different intervals by histology evaluations conducted by an ophthalmic pathologist. Temperature changes were monitored in the eyes of 4 rabbits. The nonorbital-rated transducer produced increases in ocular tissue temperature that surpassed the safe limit (increases >1.5°C) in the lens of 3 rabbits (at 5.0, 5.5, and 1.5 minutes) and cornea of 2 rabbits (both at 1

  10. Effects of emotionally affect adult and baby' photographs in healthy controls and schizophrenic patients evaluating by exploratory eye movements.

    Science.gov (United States)

    Kawabe, Chizuko; Morita, Kiichiro; Shoji, Yoshihisa; Fujiki, Ryo; Yamamoto, Atsushi; Asaumi, Yasue; Uchimura, Naohisa

    2011-01-01

    The relationship between mother and baby is of fundamental importance in the development of cognitive function and emotion. In this study we investigated the effects of affective photographs of a mother and baby (crying or smiling faces) and other stimuli (neutral mother or baby faces) on visual cognitive function in schizophrenic patents. We recorded exploratory eye movements in 22 healthy controls and 22 age-matched schizophrenic patients. Total number of right and left field gaze points (right TNGP, left TNGP) in the visual fields were determined using an eye-mark recorder as subjects viewed affectively charged or neutral photographs (crying, smiling or neutral faces). Left TNGP for all mother photographs (crying, smiling or neutral) were significantly larger in controls than patients, and right TNGP for neutral mother photographs were significantly larger in controls than in patients. Right TNGP for photographs of smiling babies were significantly larger in controls than patients, and left TNGP for photographs of both smiling and crying babies were significantly larger in controls than patients. Within the patient group, right TNGP were significantly larger than left TNGP for all mother photographs (crying, smiling or neutral). Left TNGP for photographs of mothers and babies correlated negatively with negative symptom scores. These results suggest that exploratory eye movements when viewing emotionally laded twin stimuli such as photographs of a mother and baby are a useful marker of visual cognitive function in both healthy controls and schizophrenic patients.

  11. Dipyridamole 201T1 myocardial perfusion tomography and bull's--eye analysis for quantitative evaluation of CAD

    International Nuclear Information System (INIS)

    Jiang Maosong; Tang Xi

    1992-01-01

    To assess the ability of quantitative analysis of dipyridamole 201 T1 tomography for detecting and localizing coronary artery disease (CAD), 55 patients with angiographically proved CAD ( = 50% stenosis) were studied. All patients underwent dipyridamole 201 T1 myocardial perfusion tomography and coronary arteriography. The overall sensitivity for detection of CAD by Bull's-eye analysis was 89% (50 patients) and 92% (51 patients) with visual analysis. The sensitivity for detecting individual vessel involvement with the Bull'-eye analysis was 88% for LAD. 81% for RCA and 67% for LCX. With visual analysis, the results were 88%, 83% and 58% respectively. The overall rate of detection was 87% in lesions greater than or equal to 75% stenosis vs 59% in those under 75% stenosis (P 201 T1 tomography using Bull's-eye display is a highly accurate reproducible technique for the detection of patients with CAD and the localization of individual coronary vessel, and it offers the potential to quantify the percentage of the abnormally perfused myocardium

  12. Diabetic Eye Disease

    Science.gov (United States)

    ... Disease, & Other Dental Problems Diabetes & Sexual & Urologic Problems Diabetic Eye Disease What is diabetic eye disease? Diabetic eye disease is a group ... eye diseases that can threaten your sight are Diabetic retinopathy The retina is the inner lining at ...

  13. About the Eye

    Medline Plus

    Full Text Available ... eye behind the iris that helps to focus light on the retina. It allows the eye to ... of the eye. It regulates the amount of light entering the eye through the pupil. Pupil (PYOO- ...

  14. Eye Movement Disorders

    Science.gov (United States)

    ... work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... in "crossed eyes" or "walleye." Nystagmus - fast, uncontrollable movements of the eyes, sometimes called "dancing eyes" Some ...

  15. About the Eye

    Medline Plus

    Full Text Available ... for Kids >> About the Eye Listen All About Vision About the Eye Ask a Scientist Video Series ... Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun ...

  16. Why Do Eyes Water?

    Science.gov (United States)

    ... for Educators Search English Español Why Do Eyes Water? KidsHealth / For Kids / Why Do Eyes Water? What's ... coming out of your nose. Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  17. Comparing Hp(3) evaluated from the conversion coefficients from air kerma to personal dose equivalent for eye lens dosimetry calibrated on a new cylindrical PMMA phantom

    Science.gov (United States)

    Esor, J.; Sudchai, W.; Monthonwattana, S.; Pungkun, V.; Intang, A.

    2017-06-01

    Based on a new occupational dose limit recommended by ICRP (2011), the annual dose limit for the lens of the eye for workers should be reduced from 150 mSv/y to 20 mSv/y averaged over 5 consecutive years in which no single year exceeding 50 mSv. This new dose limit directly affects radiologists and cardiologists whose work involves high radiation exposure over 20 mSv/y. Eye lens dosimetry (Hp(3)) has become increasingly important and should be evaluated directly based on dosimeters that are worn closely to the eye. Normally, Hp(3) dose algorithm was carried out by the combination of Hp(0.07) and Hp(10) values while dosimeters were calibrated on slab PMMA phantom. Recently, there were three reports from European Union that have shown the conversion coefficients from air kerma to Hp(3). These conversion coefficients carried out by ORAMED, PTB and CEA Saclay projects were performed by using a new cylindrical head phantom. In this study, various delivered doses were calculated using those three conversion coefficients while nanoDot, small OSL dosimeters, were used for Hp(3) measurement. These calibrations were performed with a standard X-ray generator at Secondary Standard Dosimetry Laboratory (SSDL). Delivered doses (Hp(3)) using those three conversion coefficients were compared with Hp(3) from nanoDot measurements. The results showed that percentage differences between delivered doses evaluated from the conversion coefficient of each project and Hp(3) doses evaluated from the nanoDots were found to be not exceeding -11.48 %, -8.85 % and -8.85 % for ORAMED, PTB and CEA Saclay project, respectively.

  18. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ...

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  20. What Is Dry Eye?

    Science.gov (United States)

    ... Eye? Dry Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Inside of Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  1. Cosmetics Europe compilation of historical serious eye damage/eye irritation in vivo data analysed by drivers of classification to support the selection of chemicals for development and evaluation of alternative methods/strategies: the Draize eye test Reference Database (DRD).

    Science.gov (United States)

    Barroso, João; Pfannenbecker, Uwe; Adriaens, Els; Alépée, Nathalie; Cluzel, Magalie; De Smedt, Ann; Hibatallah, Jalila; Klaric, Martina; Mewes, Karsten R; Millet, Marion; Templier, Marie; McNamee, Pauline

    2017-02-01

    A thorough understanding of which of the effects assessed in the in vivo Draize eye test are responsible for driving UN GHS/EU CLP classification is critical for an adequate selection of chemicals to be used in the development and/or evaluation of alternative methods/strategies and for properly assessing their predictive capacity and limitations. For this reason, Cosmetics Europe has compiled a database of Draize data (Draize eye test Reference Database, DRD) from external lists that were created to support past validation activities. This database contains 681 independent in vivo studies on 634 individual chemicals representing a wide range of chemical classes. A description of all the ocular effects observed in vivo, i.e. degree of severity and persistence of corneal opacity (CO), iritis, and/or conjunctiva effects, was added for each individual study in the database, and the studies were categorised according to their UN GHS/EU CLP classification and the main effect driving the classification. An evaluation of the various in vivo drivers of classification compiled in the database was performed to establish which of these are most important from a regulatory point of view. These analyses established that the most important drivers for Cat 1 Classification are (1) CO mean ≥ 3 (days 1-3) (severity) and (2) CO persistence on day 21 in the absence of severity, and those for Cat 2 classification are (3) CO mean ≥ 1 and (4) conjunctival redness mean ≥ 2. Moreover, it is shown that all classifiable effects (including persistence and CO = 4) should be present in ≥60 % of the animals to drive a classification. As a consequence, our analyses suggest the need for a critical revision of the UN GHS/EU CLP decision criteria for the Cat 1 classification of chemicals. Finally, a number of key criteria are identified that should be taken into consideration when selecting reference chemicals for the development, evaluation and/or validation of alternative methods and

  2. Dry eyes: etiology and management.

    Science.gov (United States)

    Latkany, Robert

    2008-07-01

    Until recently, the cause of dry eye syndrome was uncertain and the treatment was palliative. Since discovering that dry eyes are caused by inflammation, there has been an abundance of research focusing on anti-inflammatory therapies, other contributing causes, and better diagnostic testing. This review summarizes some of the interesting published research on ocular surface disease over the past year. The definition of dry eye now highlights the omnipresent symptom of blurry vision. The re-evaluation of ocular surface staining, tear meniscus height, and visual change will allow for a better diagnosis and understanding of dry eyes. Punctal plugs, and oral and topical anti-inflammatory use will strengthen our arsenal against ocular surface disease. Major progress has occurred in the past few years in gaining a better understanding of the etiology of dry eye syndrome, which will inevitably lead to more effective therapeutic options.

  3. Eye Contricks

    Directory of Open Access Journals (Sweden)

    N Wade

    2011-04-01

    Full Text Available Icons are eye-cons: they provide a distillation of a complex object or idea into a simple pictorial shape. They create the impression of representing that which cannot be presented. Even at the level of the photograph, the links between icon and object are tenuous. The dimension of distance or depth is missing from the icon, and this alone introduces all manner of potential ambiguities. The history of art can be considered as an exploration of the missing link between icon and object. Eye-cons are more honest—they are tricks of vision so that what is seen does not necessarily correspond to what is presented. They are visual allusions rather than visual illusions, although they can display illusory effects. At its broadest, icon can be equated with image. The concept of image has thrived on its vagueness, and so attempts have been made to refine it. An icon corresponds to an optical image: it shares some of the projective characteristics of the object represented. Written words are also icons but they do not resemble the objects they represent—they are stylised or conventional rather than spatialised and projective. Words and images were set in delightful opposition by René Magritte (1898-1967 in a series of pipe paintings, and he also played on the theme of the arbitrariness of the verbal labels assigned to objects. What is surprising is that Magritte did not apply his painterly skills to transforming the word shapes he used. A similar reluctance to transform the typefaces pervades visual poetry. My interests are in the visual rather than the poetic dimension, and I will present a range of my own eye contricks which play with letter and word shapes in a variety of ways.

  4. Fundamental Evaluation of Adaptation and Human Capabilities in a Condition Using a System to Give a User an Artificial Oculomotor Function to Control Directions of Both Eyes Independently

    Directory of Open Access Journals (Sweden)

    Fumio Mizuno

    2011-10-01

    Full Text Available To investigate flexible adaptation of visual system, we developed a system to provide a user an artificial oculomotor function to control directions of both eyes. The system named “Virtual Chameleon” consists of two CCD cameras independently controlled and a head-mounted display. The user can control each tracking directions of two cameras with sensors set to both hands so that the user can get independent arbitrary view fields for both eyes. We performed fundamental experiments to evaluate capability to evaluate adaptation to use of Virtual Chameleon and effects on the user's capabilities. Eleven healthy volunteers with normal and corrected-to-normal vision participated in the experiments. The experiments were tests to find out each position of targets put in both side of a subject. In the experiments, a condition using Virtual Chameleon and a condition without it was adopted. We obtained accuracy rates and time intervals to find out target positions as experimental results. The experiments showed all of volunteers became able to actively control independent visual axes and correctly understood two different views by using Virtual Chameleon, even though two independent view fields yielded binocular rivalry to volunteers and binocular rivalry reduced human capabilities compared to cases without Virtual Chameleon.

  5. A controlled multi-center study evaluating the efficacy of Vivité skin care in the treatment of photoaging of the face, eye and mouth.

    Science.gov (United States)

    Goldman, Mitchel P; Gold, Michael H

    2010-01-01

    To determine the efficacy of a skin care system developed with a partially neutralized glycolic compound and natural antioxidants when compared to Cetaphil moisturizing regimen for the treatment of photoaging of the face, eye and mouth. A total of 36 patients between 35 and 65 years of age were randomized on a 3:1 ratio to use either Vivité Skin Care System or Cetaphil cleanser and moisturizer for 60 days. Facial skin was evaluated at baseline, day 30 and day 60. Subjects were required to fill out a self-evaluation of facial skin quality before, during, and after treatment. Investigators evaluated facial wrinkling using a common wrinkling scale as well as a visual evaluation of skin texture in a masked manner. A similar proportion of patients in each group had a 1-point improvement on the hyperpigmentation scale (42% of Vivité patients, 44% of Cetaphil patients). There were no statistically significant between-group differences in investigator rating of wrinkles. Subjectively, patients preferred Vivité to Cetaphil for noticeable improvement in fine lines or wrinkles (37.6-0%, respectively) at the first follow-up. By the final follow-up, more than half the patients in the Vivité group continued to notice an improvement in fine lines or wrinkles, compared with fewer than 25% in the Cetaphil group. More than twice the number of patients in the Vivité group noticed improvement in skin elasticity or tightness compared with those in the Cetaphil group. Patients reported that the Vivité skin care system improved the appearance of wrinkling and improved skin texture associated with moderate photoaging of the face, eye and mouth areas. Vivité had a higher patient preference rating than a commonly used moisturizing regimen. There were no differences noted in the physician evaluations.

  6. Impact of dry eye on work productivity

    Directory of Open Access Journals (Sweden)

    Yamada M

    2012-10-01

    Full Text Available Masakazu Yamada, Yoshinobu Mizuno, Chika ShigeyasuNational Institute of Sensory Organs, National Hospital Organization Tokyo Medical Center, Tokyo, JapanBackground: The purpose of this study was to evaluate the impact of dry eye on work productivity of office workers, especially in terms of presenteeism.Methods: A total of 396 individuals aged ≥20 years (258 men and 138 women, mean age 43.4 ± 13.0 years were recruited through an online survey. Data from 355 responders who did not have missing values were included in the analysis. They were classified into the following four groups according to the diagnostic status and subjective symptoms of dry eye: a definite dry eye group; a marginal dry eye group; a self-reported dry eye group; and a control group. The impact of dry eye on work productivity was evaluated using the Japanese version of the Work Limitations Questionnaire. The cost of work productivity loss associated with dry eye and the economic benefits of providing treatment for dry eye were also assessed.Results: The degree of work performance loss was 5.65% in the definite dry eye group, 4.37% in the marginal dry eye group, 6.06% in the self-reported dry eye group, and 4.27% in the control group. Productivity in the self-reported dry eye group was significantly lower than that in the control group (P < 0.05. The annual cost of work productivity loss associated with dry eye was estimated to be USD 741 per person.Conclusion: Dry eye impairs work performance among office workers, which may lead to a substantial loss to industry. Management of symptoms of dry eye by providing treatment may contribute to improvement in work productivity.Keywords: burden of disease, dry eye, presenteeism, quality of life

  7. Establishment of a new immortalized human corneal epithelial cell line (iHCE-NY1) for use in evaluating eye irritancy by in vitro test methods.

    Science.gov (United States)

    Yamamoto, Naoki; Kato, Yoshinao; Sato, Atsushi; Hiramatsu, Noriko; Yamashita, Hiromi; Ohkuma, Mahito; Miyachi, Ei-Ichi; Horiguchi, Masayuki; Hirano, Koji; Kojima, Hajime

    2016-08-01

    In vitro test methods that use human corneal epithelial cells to evaluate the eye irritation potency of chemical substances do not use human corneal epithelium because it has been difficult to maintain more than four passages. In this study, we make a new cell line comprising immortalized human corneal epithelial cells (iHCE-NY1). The IC50 of iHCE-NY1 cells is slightly higher than that of Statens Seruminstitut Rabbit Cornea (SIRC) cells, which are currently used in some in vitro test methods. CDKN1A in iHCE-NY1 cells was used as a marker of gene expression to indicate cell cycle activity. This enabled us to evaluate cell recovery characteristics at concentrations lower than the IC50 of cytotoxic tests.

  8. Epidemiological evaluation of YAG capsulotomy incidence for posterior capsule opacification in various intraocular lenses in Japanese eyes

    Directory of Open Access Journals (Sweden)

    Nishi Y

    2015-09-01

    Full Text Available Yutaro Nishi,1,2 Tomohiro Ikeda,1 Kayo Nishi,2 Osamu Mimura1 1Department of Ophthalmology, Hyogo College of Medicine, Hyogo, 2Nishi Eye Hospital, Osaka, Japan Background and objective: We investigated the yttrium aluminum garnet (YAG capsulotomy rates in various intraocular lenses (IOLs. Study design/patients and methods: We retrospectively analyzed 23,440 eyes implanted with either MA60BM, MA60AC, VA-60BB, CeeOnEdge, Clariflex, Technis Z9002, SI-40NB, or UV26T IOLs. We calculated the YAG capsulotomy rates at 1, 3, 5, and 10 years post lens implantation. Results: YAG capsulotomy rates at 3 years postimplantation for the eight groups of IOLs were, respectively, 3.7%, 3.9%, 23.7%, 3.4%, 4.5%, 4.7%, 10.4%, and 21.0%. YAG capsulotomy rates at 10 years postimplantation for the MA60BM and SI-40NB IOLs were, respectively, 9.1% and 15% (P<0.05. The average YAG rates for all sharp-edged and round-edged IOLs at 5 years postimplantation were, respectively, 5.2%±0.7% and 25.6%±9.0% (P<0.05. Conclusion: In all studied IOLs, posterior capsule opacification prevention seemed to be associated with the posterior optic sharp-edge design. Round-edged silicone IOLs may also retard posterior capsule opacification formation, though not as much as sharp-edged IOLs. As the follow-up period progressed, round-edged silicone IOLs showed significantly higher YAG rates than sharp-edged IOLs. Keywords: silicone, intraocular lenses, sharp optic edge, chi-square test, implantation surgery, posterior capsule opacification

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Dry Eye ... Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué es el ojo seco? Written By: Kierstan ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué ... Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  11. Bags Under Eyes

    Science.gov (United States)

    Bags under eyes Overview Bags under eyes — mild swelling or puffiness under the eyes — are common as you age. With aging, the tissues around your ... space below your eyes, adding to the swelling. Bags under eyes are usually a cosmetic concern and ...

  12. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables About the Eye Your eyes ...

  13. Evaluation of tensile strength of tissue adhesives and sutures for clear corneal incisions using porcine and bovine eyes, with a novel standardized testing platform

    Directory of Open Access Journals (Sweden)

    Kaja S

    2012-02-01

    Full Text Available Simon Kaja, Daryl L Goad, Fatima Ali, Ashley Abraham, R Luke Rebenitsch, Savak Teymoorian, Rohit Krishna, Peter KoulenVision Research Center and Department of Ophthalmology, University of Missouri-Kansas City, School of Medicine, Kansas City, MO, USABackground: Tissue adhesives for ophthalmologic applications were proposed almost 50 years ago, yet to date no adequate tissue glues have been identified that combine strong sealing properties with adequate safety and absence of postsurgical side effects. In recent years, cataract surgeries and Descemet's stripping with endothelial keratoplasty procedures have significantly increased the number of clear corneal incisions performed. One of the obstacles to discovery and development of novel tissue adhesives has been the result of nonstandardized testing of potential tissue glues.Methods: We developed an instrument capable of controlling intraocular pressure in explanted porcine and bovine eyes in order to evaluate sealants, adhesives, and surgical closure methods used in ophthalmic surgery in a controlled, repeatable, and validated fashion. We herein developed and validated our instrument by testing the adhesive properties of cyanoacrylate glue in both porcine and bovine explant eyes.Results: The instrument applied and maintained intraocular pressure through a broad range of physiological intraocular pressures. Cyanoacrylate-based glues showed significantly enhanced sealing properties of clear corneal incisions compared with sutured wounds.Conclusion: This study shows the feasibility of our instrument for reliable and standardized testing of tissue adhesive for ophthalmological surgery.Keywords: manometer, intraocular pressure, applanation tonometry, clear corneal incision, tissue adhesive, ocular surgery

  14. PROSPECTIVE EVALUATION OF VISUAL ACUITY AGREEMENT BETWEEN STANDARD EARLY TREATMENT DIABETIC RETINOPATHY STUDY CHART AND A HANDHELD EQUIVALENT IN EYES WITH RETINAL PATHOLOGY.

    Science.gov (United States)

    Rahimy, Ehsan; Reddy, Sahitya; DeCroos, Francis Char; Khan, M Ali; Boyer, David S; Gupta, Omesh P; Regillo, Carl D; Haller, Julia A

    2015-08-01

    To evaluate the visual acuity agreement between a standard back-illuminated Early Treatment Diabetic Retinopathy Study (ETDRS) chart and a handheld internally illuminated ETDRS chart. Two-center prospective study. Seventy patients (134 eyes) with retinal pathology were enrolled between October 2012 and August 2013. Visual acuity was measured using both the ETDRS chart and the handheld device by masked independent examiners after best protocol refraction. Examination was performed in the same room under identical illumination and testing conditions. The mean number of letters seen was 63.0 (standard deviation: 19.8 letters) and 61.2 letters (standard deviation: 19.1 letters) for the ETDRS chart and handheld device, respectively. Mean difference per eye between the ETDRS and handheld device was 1.8 letters. A correlation coefficient (r) of 0.95 demonstrated a positive linear correlation between ETDRS chart and handheld device measured acuities. Intraclass correlation coefficient was performed to assess the reproducibility of the measurements made by different observers measuring the same quantity and was calculated to be 0.95 (95% confidence interval: 0.93-0.96). Agreement was independent of retinal disease. The strong correlation between measured visual acuity using the ETDRS and handheld equivalent suggests that they may be used interchangeably, with accurate measurements. Potential benefits of this device include convenience and portability, as well as the ability to assess ETDRS visual acuity without a dedicated testing lane.

  15. Adaptive statistical iterative reconstruction and bismuth shielding for evaluation of dose reduction to the eye and image quality during head CT

    Science.gov (United States)

    Kim, Myeong Seong; Choi, Jiwon; Kim, Sun Young; Kweon, Dae Cheol

    2014-03-01

    There is a concern regarding the adverse effects of increasing radiation doses due to repeated computed tomography (CT) scans, especially in radiosensitive organs and portions thereof, such as the lenses of the eyes. Bismuth shielding with an adaptive statistical iterative reconstruction (ASIR) algorithm was recently introduced in our clinic as a method to reduce the absorbed radiation dose. This technique was applied to the lens of the eye during CT scans. The purpose of this study was to evaluate the reduction in the absorbed radiation dose and to determine the noise level when using bismuth shielding and the ASIR algorithm with the GE DC 750 HD 64-channel CT scanner for CT of the head of a humanoid phantom. With the use of bismuth shielding, the noise level was higher in the beam-hardening artifact areas than in the revealed artifact areas. However, with the use of ASIR, the noise level was lower than that with the use of bismuth alone; it was also lower in the artifact areas. The reduction in the radiation dose with the use of bismuth was greatest at the surface of the phantom to a limited depth. In conclusion, it is possible to reduce the radiation level and slightly decrease the bismuth-induced noise level by using a combination of ASIR as an algorithm process and bismuth as an in-plane hardware-type shielding method.

  16. Adaptive statistical iterative reconstruction and bismuth shielding for evaluation of dose reduction to the eye and image quality during head CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Seong [The Korean National Cancer Center, Goyang (Korea, Republic of); Seoul National University, Seoul (Korea, Republic of); Choi, Ji Won [Jeonju University, Jeonju (Korea, Republic of); Kim, Sun Young [Hallym University of Graduate Studies, Seoul (Korea, Republic of); The Korean National Cancer Center, Goyang (Korea, Republic of); Kweon, Dae Cheol [Shinhan University, Uijeongbu (Korea, Republic of)

    2014-03-15

    There is a concern regarding the adverse effects of increasing radiation doses due to repeated computed tomography (CT) scans, especially in radiosensitive organs and portions thereof, such as the lenses of the eyes. Bismuth shielding with an adaptive statistical iterative reconstruction (ASIR) algorithm was recently introduced in our clinic as a method to reduce the absorbed radiation dose. This technique was applied to the lens of the eye during CT scans. The purpose of this study was to evaluate the reduction in the absorbed radiation dose and to determine the noise level when using bismuth shielding and the ASIR algorithm with the GE DC 750 HD 64-channel CT scanner for CT of the head of a humanoid phantom. With the use of bismuth shielding, the noise level was higher in the beam-hardening artifact areas than in the revealed artifact areas. However, with the use of ASIR, the noise level was lower than that with the use of bismuth alone; it was also lower in the artifact areas. The reduction in the radiation dose with the use of bismuth was greatest at the surface of the phantom to a limited depth. In conclusion, it is possible to reduce the radiation level and slightly decrease the bismuth-induced noise level by using a combination of ASIR as an algorithm process and bismuth as an in-plane hardware-type shielding method.

  17. About the Eye

    Medline Plus

    Full Text Available ... your eye. It helps your eye focus light so things look sharp and clear. Sclera (SKLEH-ruh) ... the different parts of your eye work together so you can see and make sense of the ...

  18. About the Eye

    Medline Plus

    Full Text Available ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... to More Information Optical Illusions Printables About the Eye Your eyes are made up of many different ...

  19. Fluorescein eye stain

    Science.gov (United States)

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... object in eye ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  20. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Member Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member ... Center Redmond Ethics Center Global Ophthalmology Guide Eye Health Find an Ophthalmologist Academy Store Eye Health A- ...

  1. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On ... Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms Causes of ...

  2. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Dry Eye Symptoms Related Ask an Ophthalmologist Answers Can a six-month dissolvable punctal plug be removed ... my eyes dry after LASIK? Jun 19, 2016 Can I be tested whether I close my eyes ...

  3. Eye Injuries at Work

    Science.gov (United States)

    ... National Standards Institute (ANSI) to meet their eye protection standards. If an eye injury occurs, see an ophthalmologist or go to the emergency room immediately, even if the eye injury appears minor. Delaying medical attention can result in permanent vision ...

  4. EyeGENE

    Data.gov (United States)

    U.S. Department of Health & Human Services — The eyeGENE® Biorepository and corresponding Database contain family history and clinical eye exam data from subjects enrolled in eyeGENE® Program coupled to...

  5. Impact of dry eye on work productivity.

    Science.gov (United States)

    Yamada, Masakazu; Mizuno, Yoshinobu; Shigeyasu, Chika

    2012-01-01

    The purpose of this study was to evaluate the impact of dry eye on work productivity of office workers, especially in terms of presenteeism. A total of 396 individuals aged ≥20 years (258 men and 138 women, mean age 43.4 ± 13.0 years) were recruited through an online survey. Data from 355 responders who did not have missing values were included in the analysis. They were classified into the following four groups according to the diagnostic status and subjective symptoms of dry eye: a definite dry eye group; a marginal dry eye group; a self-reported dry eye group; and a control group. The impact of dry eye on work productivity was evaluated using the Japanese version of the Work Limitations Questionnaire. The cost of work productivity loss associated with dry eye and the economic benefits of providing treatment for dry eye were also assessed. The degree of work performance loss was 5.65% in the definite dry eye group, 4.37% in the marginal dry eye group, 6.06% in the self-reported dry eye group, and 4.27% in the control group. Productivity in the self-reported dry eye group was significantly lower than that in the control group (P work productivity loss associated with dry eye was estimated to be USD 741 per person. Dry eye impairs work performance among office workers, which may lead to a substantial loss to industry. Management of symptoms of dry eye by providing treatment may contribute to improvement in work productivity.

  6. A nonrandomized, open-label study to evaluate the effect of nasal stimulation on tear production in subjects with dry eye disease.

    Science.gov (United States)

    Friedman, Neil J; Butron, Karla; Robledo, Nora; Loudin, James; Baba, Stephanie N; Chayet, Arturo

    2016-01-01

    Dry eye disease (DED), a chronic disorder affecting the tear film and lacrimal functional unit, is a widely prevalent condition associated with significant burden and unmet treatment needs. Since specific neural circuits play an important role in maintaining ocular surface health, microelectrical stimulation of these pathways could present a promising new approach to treating DED. This study evaluated the efficacy and safety of nasal electrical stimulation in patients with DED. This prospective, open-label, single-arm, nonrandomized pilot study included 40 patients with mild to severe DED. After undergoing two screening visits, enrolled subjects were provided with a nasal stimulation device and instructed to use it at home four times daily (or more often as needed). Follow-up assessments were conducted up to day 180. The primary efficacy endpoint was the difference between unstimulated and stimulated tear production quantified by Schirmer scores. Additional efficacy endpoints included change from baseline in corneal and conjunctival staining, symptoms evaluated on a Visual Analog Scale, and Ocular Surface Disease Index scores. Safety parameters included adverse event (AE) rates, visual acuity, intraocular pressure, slit-lamp biomicroscopy, indirect ophthalmoscopy, and endoscopic nasal examinations. Mean stimulated Schirmer scores were significantly higher than the unstimulated scores at all visits, and corneal and conjunctival staining and symptom scores from baseline to day 180 were significantly reduced. No serious device-related AEs and nine nonserious AEs (three device-related) were reported. Intraocular pressure remained stable and most subjects showed little or no change in visual acuity at days 30 and 180. No significant findings from other clinical examinations were noted. Neurostimulation of the nasolacrimal pathway is a safe and effective means of increasing tear production and reducing symptoms of dry eye in patients with DED.

  7. Weighting Performance Evaluation Criteria Base in Balanced Score Card Approach with Use of Combination Method Shapley value & Bull\\'s-eye

    Directory of Open Access Journals (Sweden)

    Mohammad Hassan Kamfiroozi

    2014-05-01

    Full Text Available Performance evaluation as a control tool was considered by managers in the organizations and manufactures. In this paper we decide to present a new model for performance evaluation and industrial companies ranking at uncertain conditions. Based on this, we implemented performance evaluation based on balance score card (BSC method. Beside, we tried to use three parameter interval grey numbers in lieu of linguistic variables. Then evaluation and weighting of fourth indicators is done with use of Bulls-eye-Shapley combination method that is counted as new approach in this article. Reason of utilization of three parameter interval grey numbers and combination method was decreasing of environmental uncertainty on data and model. This combination weighting method can be used as a new method in decision making Science. At final of this paper case study was implemented on industrial companies (nail makers that ranking of these companies is obtained by use of grey-TOPSIS method (that is a generalization of classic TOPSIS for three parameter interval grey numbers.

  8. Eye tracking and the translation process

    DEFF Research Database (Denmark)

    Hvelplund, Kristian Tangsgaard

    2014-01-01

    Eye tracking has become increasingly popular as a quantitative research method in translation research. This paper discusses some of the major methodological issues involved in the use of eye tracking in translation research. It focuses specifically on challenges in the analysis and interpretation...... of eye-tracking data as reflections of cognitive processes during translation. Four types of methodological issues are discussed in the paper. The first part discusses the preparatory steps that precede the actual recording of eye-tracking data. The second part examines critically the general assumptions...... linking eye movements to cognitive processing in the context of translation research. The third part of the paper discusses two popular eye-tracking measures often used in translation research, fixations and pupil size, while the fourth part proposes a method to evaluate the quality of eye-tracking data....

  9. Autologous serum eye drops for dry eye

    Science.gov (United States)

    Pan, Qing; Angelina, Adla; Marrone, Michael; Stark, Walter J; Akpek, Esen K

    2017-01-01

    Background Theoretically, autologous serum eye drops (AS) offer a potential advantage over traditional therapies on the assumption that AS not only serve as a lacrimal substitute to provide lubrication but contain other biochemical components that allow them to mimic natural tears more closely. Application of AS has gained popularity as second-line therapy for patients with dry eye. Published studies on this subject indicate that autologous serum could be an effective treatment for dry eye. Objectives We conducted this review to evaluate the efficacy and safety of AS given alone or in combination with artificial tears as compared with artificial tears alone, saline, placebo, or no treatment for adults with dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2016), Embase (January 1980 to July 2016), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (December 2016) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 5 July 2016. Selection criteria We included randomized controlled trials (RCTs) that compared AS versus artificial tears for treatment of adults with dry eye. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text reports of potentially eligible trials. Two review authors extracted data and assessed risk of bias and characteristics of included

  10. Morphofunctional evaluation of the testicle and the spermatogenic process of adult white-eyed parakeets (Aratinga leucophthalma MULLER, 1776) during the different seasons of the year.

    Science.gov (United States)

    Peixoto, J V; Paula, T A R; Balarini, M K; Matta, S L P; Santos, J A D; Lima, C B; Peixoto, G V

    2012-08-01

    In this experiment, testicle fragments of 14 adult White-eyed Parakeets (Aratinga leucophthalma) were evaluated as for their seasonal reproductive activities using the following quantitative parameters: average thickness of the testicular tunica albuginea, volumetric proportion of tubular and extratubular compartments, average diameter of the seminiferous tubules and corporal weight. Parameters were created for qualitative evaluations of the degree of spermatogenic development. In this experiment, all the animals were distributed into four groups, and their testicular fragments were collected during the middle of summer, fall, winter and spring. The animals were submitted to volatile general anaesthesia, and a biopsy was made by celioscopy. The fragments collected were processed histologically. The slides were prepared and later evaluated by using an optical microscope. The average seasonal values of the corporal weight increased, starting in the winter and reaching the peak during the spring. A seasonal testicle cycle was observed, because, in the spring, the testicles showed values for the quantitative and qualitative parameters of spermatic production compatible with the period of greater activity, while the opposite thing happened during the fall. Our data indicate that the parameters of sperm production may be correlated with daily light rather than with air humidity. © 2012 Blackwell Verlag GmbH.

  11. Eyes on the prize or nose to the grindstone? The effects of level of goal evaluation on mood and motivation.

    Science.gov (United States)

    Houser-Marko, Linda; Sheldon, Kennon M

    2008-11-01

    These studies tested the hypothesis that evaluating goal feedback in terms of a primary, longer term goal can be risky for future motivation. Study 1 was a 2 x 2 experiment in which framing level (primary goal/subgoal) and feedback valence (success/failure) were manipulated for participants during a verbal skills task. In the primary goal failure condition, there was increased negative mood and decreased positive mood and expectancy for subsequent trials, even while controlling for goal difficulty and importance. Study 2 was an 8-week study throughout which participants were asked to evaluate their progress regarding a primary goal (class grade goal) or subgoal (weekly study hours goal), and success or failure varied naturally. When progress was lacking, participants in the primary goal condition experienced the largest decreases in mood and expectancy. These results suggest that it is optimal to evaluate goal progress at the lower, subgoal level, particularly after failure feedback.

  12. Seeing the System through the End Users' Eyes: Shadow Expert Technique for Evaluating the Consistency of a Learning Management System

    Science.gov (United States)

    Holzinger, Andreas; Stickel, Christian; Fassold, Markus; Ebner, Martin

    Interface consistency is an important basic concept in web design and has an effect on performance and satisfaction of end users. Consistency also has significant effects on the learning performance of both expert and novice end users. Consequently, the evaluation of consistency within a e-learning system and the ensuing eradication of irritating discrepancies in the user interface redesign is a big issue. In this paper, we report of our experiences with the Shadow Expert Technique (SET) during the evaluation of the consistency of the user interface of a large university learning management system. The main objective of this new usability evaluation method is to understand the interaction processes of end users with a specific system interface. Two teams of usability experts worked independently from each other in order to maximize the objectivity of the results. The outcome of this SET method is a list of recommended changes to improve the user interaction processes, hence to facilitate high consistency.

  13. Is Beauty in the Eyes of the Beholder? Aesthetic Quality versus Technical Skill in Movement Evaluation of Tai Chi.

    Science.gov (United States)

    Zamparo, Paola; Zorzi, Elena; Marcantoni, Sara; Cesari, Paola

    2015-01-01

    The aim of this study was to compare experts to naïve practitioners in rating the beauty and the technical quality of a Tai Chi sequence observed in video-clips (of high and middle level performances). Our hypothesis are: i) movement evaluation will correlate with the level of skill expressed in the kinematics of the observed action but ii) only experts will be able to unravel the technical component from the aesthetic component of the observed action. The judgments delivered indicate that both expert and non-expert observers are able to discern a good from a mediocre performance; however, as expected, only experts discriminate the technical from the aesthetic component of the action evaluated and do this independently of the level of skill shown by the model (high or middle level performances). Furthermore, the judgments delivered were strongly related to the kinematic variables measured in the observed model, indicating that observers rely on specific movement kinematics (e.g. movement amplitude, jerk and duration) for action evaluation. These results provide evidence of the complementary functional role of visual and motor action representation in movement evaluation and underline the role of expertise in judging the aesthetic quality of movements.

  14. Functional and Morphological Evaluation of Traumatized Eyes With Berlin's Edema Affecting the Macula Using mfERG, Microperimetry, and SD-OCT.

    Science.gov (United States)

    Boss, Joseph Daniel; Tosi, Joaquin; Glybina, Inna; Tewari, Asheesh; Abrams, Gary W

    2017-02-01

    To describe the structural and functional changes that occur in traumatic Berlin's edema involving the macula through assessment with multifocal electroretinogram (mfERG), microperimetry, fundus photography, and spectral-domain optical coherence tomography (SD-OCT). Retrospective case series of five eyes from four patients with macular traumatic Berlin's edema. Patients underwent baseline mfERG (three eyes), MP1 microperimetry (three eyes), fundus photography (five eyes), and SD-OCT (five eyes). All eyes with Berlin's edema showed abnormal findings on baseline SD-OCT, including disruption and fragmentation of the inner segment/ outer segment layer. In two patients with unilateral blunt ocular trauma who underwent mfERG, there was complete loss of the foveal peak in affected eyes. All three eyes that underwent microperimetry showed depressed retinal sensitivity in the area of Berlin's edema. SD-OCT, microperimetry, and mfERG can be used to help diagnose, stratify traumatic severity, and follow structural and functional progression over time in patients with Berlin's edema. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:114-121.]. Copyright 2017, SLACK Incorporated.

  15. The effect of gaze angle on the evaluations of SAR and temperature rise in human eye under plane-wave exposures from 0.9 to 10 GHz

    International Nuclear Information System (INIS)

    Diao, Yinliang; Leung, Sai-Wing; Sun, Weinong; Siu, Yun-Ming; Kong, Richard; Hung Chan, Kwok

    2016-01-01

    This article investigates the effect of gaze angle on the specific absorption rate (SAR) and temperature rise in human eye under electromagnetic exposures from 0.9 to 10 GHz. Eye models in different gaze angles are developed based on bio-metric data. The spatial-average SARs in eyes are investigated using the finite-difference time-domain method, and the corresponding maximum temperature rises in lens are calculated by the finite-difference method. It is found that the changes in the gaze angle produce a maximum variation of 35, 12 and 20 % in the eye-averaged SAR, peak 10 g average SAR and temperature rise, respectively. Results also reveal that the eye-averaged SAR is more sensitive to the changes in the gaze angle than peak 10 g average SAR, especially at higher frequencies. (authors)

  16. The eye amputated - consequences of eye amputation with emphasis on clinical aspects, phantom eye syndrome and quality of life

    DEFF Research Database (Denmark)

    Rasmussen, Marie Louise Roed

    2010-01-01

    In this thesis the term eye amputation (EA) covers the removing of an eye by: evisceration, enucleation and exenteration. Amputation of an eye is most frequently the end-stage in a complicated disease, or the primary treatment in trauma and neoplasm. In 2010 the literature is extensive due...... to knowledge about types of surgery, implants and surgical technique. However, not much is known about the time past surgery. THE PURPOSE OF THE PHD THESIS WAS: To identify the number of EA, the causative diagnosis and the indication for surgical removal of the eye, the chosen surgical technique...... and to evaluate a possible change in surgical technique in Denmark from 1996 until 2003 (paper I); To describe the phantom eye syndrome and its prevalence of visual hallucinations, phantom pain and phantom sensations (paper II); To characterise the quality of phantom eye pain, including its intensity...

  17. Application of SV40 T-transformed human corneal epithelial cells to evaluate potential irritant chemicals for in vitro alternative eye toxicity.

    Science.gov (United States)

    Kim, Cho-Won; Park, Geon-Tae; Bae, Ok-Nam; Noh, Minsoo; Choi, Kyung-Chul

    2016-01-01

    Assessment of eye irritation potential is important to human safety, and it is necessary for various cosmetics and chemicals that may contact the human eye. Until recently, the Draize test was considered the standard method for estimating eye irritation, despite its disadvantages such as the need to sacrifice many rabbits for subjective scoring. Thus, we investigated the cytotoxicity and inflammatory response to standard eye irritants using SV40 T-transformed human corneal epithelial (SHCE) cells as a step toward development of an animal-free alternative eye irritation test. MTT and NRU assays of cell viability were performed to investigate the optimal experimental conditions for SHCE cell viability when cells were exposed to sodium dodecyl sulfate (SDS) as a standard eye irritant at 6.25×10(-3) to 1×10(-1)%. Additionally, cell viability of SHCE cells was examined in response to six potential eye irritants, benzalkonium chloride, dimethyl sulfoxide, isopropanol, SDS, Triton X-100 and Tween 20 at 5×10(-3) to 1×10(-1)%. Finally, we estimated the secretion level of cytokines in response to stimulation by eye irritants in SHCE cells. SHCE cells showed a good response to potential eye irritants when the cells were exposed to potential irritants for 10min at room temperature (RT), and cytokine production increased in a concentration-dependent manner, indicating that cytotoxicity and cytokine secretion from SHCE cells may be well correlated with the concentrations of irritants. Taken together, these results suggest that SHCE cells could be an excellent alternative in vitro model to replace in vivo animal models for eye irritation tests. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. A nonrandomized, open-label study to evaluate the effect of nasal stimulation on tear production in subjects with dry eye disease

    Directory of Open Access Journals (Sweden)

    Friedman NJ

    2016-05-01

    Full Text Available Neil J Friedman,1 Karla Butron,2 Nora Robledo,2 James Loudin,3 Stephanie N Baba,3 Arturo Chayet2 1Department of Ophthalmology, Stanford University, Mid-Peninsula Ophthalmology Medical Group, Palo Alto, CA, USA; 2Codet Vision Institute, Tijuana, Mexico; 3Oculeve, Inc., South San Francisco, CA, USA Background: Dry eye disease (DED, a chronic disorder affecting the tear film and lacrimal functional unit, is a widely prevalent condition associated with significant burden and unmet treatment needs. Since specific neural circuits play an important role in maintaining ocular surface health, microelectrical stimulation of these pathways could present a promising new approach to treating DED. This study evaluated the efficacy and safety of nasal electrical stimulation in patients with DED. Methods: This prospective, open-label, single-arm, nonrandomized pilot study included 40 patients with mild to severe DED. After undergoing two screening visits, enrolled subjects were provided with a nasal stimulation device and instructed to use it at home four times daily (or more often as needed. Follow-up assessments were conducted up to day 180. The primary efficacy endpoint was the difference between unstimulated and stimulated tear production quantified by Schirmer scores. Additional efficacy endpoints included change from baseline in corneal and conjunctival staining, symptoms evaluated on a Visual Analog Scale, and Ocular Surface Disease Index scores. Safety parameters included adverse event (AE rates, visual acuity, intraocular pressure, slit-lamp biomicroscopy, indirect ophthalmoscopy, and endoscopic nasal examinations. Results: Mean stimulated Schirmer scores were significantly higher than the unstimulated scores at all visits, and corneal and conjunctival staining and symptom scores from baseline to day 180 were significantly reduced. No serious device-related AEs and nine nonserious AEs (three device-related were reported. Intraocular pressure remained

  19. Eye tracking in user experience design

    CERN Document Server

    Romano Bergstorm, Jennifer

    2014-01-01

    Eye Tracking for User Experience Design explores the many applications of eye tracking to better understand how users view and interact with technology. Ten leading experts in eye tracking discuss how they have taken advantage of this new technology to understand, design, and evaluate user experience. Real-world stories are included from these experts who have used eye tracking during the design and development of products ranging from information websites to immersive games. They also explore recent advances in the technology which tracks how users interact with mobile devices, large-screen displays and video game consoles. Methods for combining eye tracking with other research techniques for a more holistic understanding of the user experience are discussed. This is an invaluable resource to those who want to learn how eye tracking can be used to better understand and design for their users. * Includes highly relevant examples and information for those who perform user research and design interactive experi...

  20. Evaluación de la toxicidad del desodorante RLV en ojos Evaluation of RLV deodorant toxicity in eyes

    Directory of Open Access Journals (Sweden)

    Esvieta Tenorio Borroto

    2001-12-01

    Full Text Available Se realizó la evaluación del posible efecto irritante de un formulado (RLV que se empleará como desodorante y que contiene como principio activo la hexamina, la cual es empleada como antiséptico urinario. Este formulado se aplicó por vía oftálmica en 6 conejos de la raza Nueva Zelandia, durante 7 días. Las valoraciones se basan en las observaciones macroscópicas de los posibles efectos adversos que se presentan en las estructuras oculares. Para esta evaluación nos basamos en el método propuesto por Draize, así como las guías de la OECD, de acuerdo con los resultados obtenidos la forma farmacéutica elaborada a una concentración del 3 % para el desodorante, no ocasiona irritación en las estructuras oculares.An evaluation of the possible irritant effect of a formulation (RLV that will be used as a deodorant and whose active principle is hexamine, which is utilized as a urinary antiseptic, was made. This formulation was applied by ophthalmic route to 6 New Zealand breed rabbits during 7 days. The assessments take into consideration the macroscopic observations of the possible adverse effects that occur in the ocular structures. This evaluation is based on the method proposed by Draize, as well as on the guidelines of the OECD. According to the results obtained, the pharmaceutical form prepared at a concentration of 3 % for the deodorant does not cause irritation of the ocular structures.

  1. The effect of gender on eye colour variation in European populations and an evaluation of the IrisPlex prediction model

    DEFF Research Database (Denmark)

    Pietroni, Carlotta; Andersen, Jeppe D.; Johansen, Peter

    2014-01-01

    In two recent studies of Spanish individuals [1,2], gender was suggested as a factor that contributes to human eye colour variation. However, gender did not improve the predictive accuracy on blue, intermediate and brown eye colours when gender was included in the IrisPlex model [3]. In this stud...... and their corresponding predictive values using the IrisPlex prediction model [4]. The results suggested that maximum three (rs12913832, rs1800407, rs16891982) of the six IrisPlex SNPs are useful in practical forensic genetic casework.......In two recent studies of Spanish individuals [1,2], gender was suggested as a factor that contributes to human eye colour variation. However, gender did not improve the predictive accuracy on blue, intermediate and brown eye colours when gender was included in the IrisPlex model [3]. In this study......12203592). A quantitative eye colour score (Pixel Index of the Eye: PIE-score) was calculated based on digital eye images using the custom made DIAT software. The results were compared with those of Danish and Swedish population samples. As expected, we found HERC2 rs12913832 as the main predictor of human...

  2. Eyes Wide Open

    Directory of Open Access Journals (Sweden)

    Zoi Manesi

    2016-04-01

    Full Text Available Research from evolutionary psychology suggests that the mere presence of eye images can promote prosocial behavior. However, the “eye images effect” is a source of considerable debate, and findings across studies have yielded somewhat inconsistent support. We suggest that one critical factor may be whether the eyes really need to be watching to effectively enhance prosocial behavior. In three experiments, we investigated the impact of eye images on prosocial behavior, assessed in a laboratory setting. Participants were randomly assigned to view an image of watching eyes (eyes with direct gaze, an image of nonwatching eyes (i.e., eyes closed for Study 1 and averted eyes for Studies 2 and 3, or an image of flowers (control condition. Upon exposure to the stimuli, participants decided whether or not to help another participant by completing a dull cognitive task. Three independent studies produced somewhat mixed results. However, combined analysis of all three studies, with a total of 612 participants, showed that the watching component of the eyes is important for decision-making in this context. Images of watching eyes led to significantly greater inclination to offer help as compared to images of nonwatching eyes (i.e., eyes closed and averted eyes or images of flowers. These findings suggest that eyes gazing at an individual, rather than any proxy to social presence (e.g., just the eyes, serve as a reminder of reputation. Taken together, we conclude that it is “eyes that pay attention” that can lift the veil of anonymity and potentially facilitate prosocial behavior.

  3. Dry eyes : a commonly missed eye condition

    OpenAIRE

    Vella, Mario;

    2014-01-01

    Tears are an important component in providing moisture and lubrication for the eyes, thereby maintaining vision and comfort. Dry eyes (keratoconjunctivitis sicca) result when there is either decreased production of tears or by poor tear quality which in turn lead to more rapid evaporation.

  4. Plain film, CT and MRI sensibility in the evaluation of intraorbital foreign bodies in an in vitro model of the orbit and in pig eyes

    International Nuclear Information System (INIS)

    Lagalla, R.; Manfre, L.; Caronia, A.; Bencivinni, F.; Duranti, C.; Ponte, F.

    2000-01-01

    Detection and characterization of intraorbital foreign bodies (IFB) is fundamental in acute trauma setting, preventing inflammatory sequelae or complications related to IFB movements when a MRI study is planned. Papers concerning plain film and CT sensibility in IFB detection show controversial results. For this reason we investigated plain film, CT and MRI sensibility in the evaluation of IFB. For an in vitro model, specimens of dry and fresh wood, glass, iron, plastic and graphite were immersed in animal lard and in a 0.9 % sodium chloride plus 3.5 g/dl human serum albumin solution. Specimens of different size and nature where also implanted into enucleated pig eyes. Air bubbles were introduced also. Plain film, CT and MRI investigation were performed. Plain films underestimated intraocular IFB as plastic, fresh or dry wooden IFB were not demonstrated. The CT study was always able to depict and differentiate IFB according to the attenuation values. Severe artefacts prevented demonstration of iron, glass and graphite IFB on MRI, whereas plastic or wooden IFB were always detected. Despite radiographs have been suggested as a prerequisite for MR imaging, because our results showed plain film to underestimate radiolucent IFB, we suggest CT as the modality of choice when IFB has to be ruled out. (orig.)

  5. Evaluation of the transforming growth factor-beta activity in normal and dry eye human tears by CCL-185 cell bioassay.

    Science.gov (United States)

    Zheng, Xiaofen; De Paiva, Cintia S; Rao, Kavita; Li, De-Quan; Farley, William J; Stern, Michael; Pflugfelder, Stephen C

    2010-09-01

    To develop a new bioassay method using human lung epithelial cells (CCL-185) to assess activity of transforming growth factor beta (TGF-beta) in human tear fluid from normal subjects and patients with dry eye. Two epithelial cell lines, mink lung cells (CCL-64) and human lung cells (CCL-185), were compared to detect the active form of TGF-beta by BrdU incorporation (quantitation of cell DNA synthesis) and WST assay (metabolic activity of viable cells). The effect of TGF-beta on the growth of CCL-185 cells was observed microscopically. Human tears from normal control subjects and patients with dry eye (DE) with and without Sjögren syndrome were evaluated for TGF-beta concentration by Luminex microbead assay, and TGF-beta activity by the CCL-185 cell growth inhibition bioassay. The metabolic activity of viable CCL-185 cells, measured by WST, was shown to be proportional to the TGF-beta1 concentration (R = 0.919) and confirmed by BrdU assay (R = 0.969). Compared with CCL-185, metabolic activity of viable cells and DNA synthesis, measured by WST and BrdU incorporation assays, were shown to be less proportional to the TGF-beta1 concentration in the CCL-64 line (R = 0.42 and 0.17, respectively). Coincubation with human anti-TGF-beta1 antibody (MAB-240) yielded a dose-dependent inhibition of TGF-beta1 (0.3 ng/mL) activity. CCL-185 cell growth observed microscopically was noted to decrease in response to increasing TGF-beta1 concentrations. Levels of immuodetectable TGF-beta1 and TGF-beta2 were similar in normal and DE tears. TGF-beta bioactivity in DE human tears measured by the CCL-185 cells assay was found to be higher (9777.5 +/- 10481.9 pg/mL) than those in normal controls (4129.3 +/- 1342.9 pg/mL) (P tears and 37.6% TGF-beta in normal tears were found to be biologically active. The CCL-185 cell assay was found to be a suitable tool for assessing TGF-beta activity in human tears. Tear TGF-beta bioactivity increases in DE, particularly in Sjögren syndrome, where

  6. Through the eyes of children: Drawings as an evaluation tool for children's understanding about endangered Mexican primates.

    Science.gov (United States)

    Franquesa-Soler, Montserrat; Serio-Silva, Juan Carlos

    2017-12-01

    This study seeks to understand children's perceptions and knowledge of endangered Mexican primates. The black howler monkey (Alouatta pigra) is a charismatic species endemic to Southern Mexico, Northern Belize, and Guatemala and is a symbol of the region that fosters a sense of local pride. Therefore, it can be considered a flagship species for the forests of Southern Mexico. We evaluated the perception and knowledge that 297 Mexican elementary school children (8-10 years old) have about black howler monkeys. Specifically, we analyzed and categorized drawings made by these children based on gender, geographic context (rural or urban), and residence within or outside of Protected Areas (PAs). Student drawings were categorized into three levels of knowledge (no familiarity, basic knowledge, and sophisticated knowledge). Common misconceptions and important landscape elements for black howler conservation were gathered from these visual representations. Children were largely unfamiliar with black howlers, despite sharing the same geographical location. Knowledge was affected by context and residence, with students living within PAs more aware of black howlers than students living outside of PAs. However, overall the children showed a deep understanding of the current forest conservation situation in Southern Mexico; meaning they could be presenting a shifting baseline syndrome. The study highlights the value of assessing children's drawings as a tool that can be used to help policy makers and educational practitioners in fine-tuning educational, environmental, and marketing programs. More importantly, it is a methodology that can be applied in future research for understanding children's perceptions and knowledge about endangered species and environmental change in deciding how to improve the effectiveness of conservation messaging. © 2017 Wiley Periodicals, Inc.

  7. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Kierstan Boyd Reviewed By: Brenda Pagan-Duran MD Sep. 01, 2017 Our eyes need tears to stay ... tear duct to insert a permanent punctal plug? Sep 12, 2017 Why are my eyes bloodshot when ...

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... seasonal allergens and dry eye Apr 27, 2015 Choosing Wisely When It Comes to Eye Care, Part ... Name: Member ID: * Phone Number: * Email: * Enter code: * Message: Thank you Your feedback has been sent.

  9. About the Eye

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ...

  10. Pink Eye (Conjunctivitis)

    Science.gov (United States)

    ... or child care if you're not able to take time off — just stay consistent in practicing good hygiene. Preventing pink eye in newborns Newborns' eyes are susceptible to bacteria normally present in the mother's birth canal. ...

  11. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ... much as it does on your eyes. ... of Health | USA.gov NIH…Turning Discovery Into Health ®

  12. About the Eye

    Medline Plus

    Full Text Available ... Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ...

  13. Preventing Eye Injuries

    Science.gov (United States)

    ... Your Eyes Sep 20, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 ... Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  14. About the Eye

    Medline Plus

    Full Text Available ... National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Health Home Annual Meeting Clinical Education Practice Management Member Services Advocacy Foundation About Subspecialties & More Academy Publications EyeNet Ophthalmology Ophthalmology Retina Information for: International Ophthalmologists Media Medical Students Patients and ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... right type of tears or tear film . How do tears work? When you blink, a film of ... layer cleans the eye, washing away particles that do not belong in the eye. This layer comes ...

  17. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid ... Your eyes are made up of many different parts that work together to help you see. Check out the ...

  18. About the Eye

    Medline Plus

    Full Text Available ... Vision Education Program Hispanic/Latino Program Vision and Aging Program African American Program Training and Jobs Fellowships ... Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes ...

  19. About the Eye

    Medline Plus

    Full Text Available ... Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and ...

  20. About the Eye

    Medline Plus

    Full Text Available ... Home » NEI for Kids » About the Eye Listen All About Vision About the Eye Ask a Scientist ... you can see and make sense of the world around you. Did You Know? Vision depends on ...

  1. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI for Kids >> About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  2. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of ...

  3. Eye Involvement in TSC

    Science.gov (United States)

    ... eye involvement. Nonretinal and Retinal Eye Findings Facial angiofibromas may involve the eyelids of individuals with TSC, ... the hamartomas have many blood vessels (as are angiofibromas of the skin). Less than half of the ...

  4. What Is Dry Eye?

    Medline Plus

    Full Text Available ... removed or pushed down the tear duct to insert a permanent punctal plug? Sep 12, 2017 Why ... Eye from Jennifer Aniston Sep 02, 2016 The link between seasonal allergens and dry eye Apr 27, ...

  5. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member Services Advocacy Foundation About Subspecialties & More Academy Publications EyeNet ...

  6. About the Eye

    Medline Plus

    Full Text Available ... First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks ... website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about ...

  7. About the Eye

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home » NEI for Kids » About the Eye Listen All ... much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  8. About the Eye

    Medline Plus

    Full Text Available ... the special health problems and requirements of the blind.” News & Events Events Calendar NEI Press Releases News ... First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks ...

  9. Immunology of the eye

    OpenAIRE

    Weronika Ratajczak; Beata Tokarz-Deptuła; Wiesław Deptuła

    2018-01-01

    The eye is an organ of sight characterized by unusual immunological properties, resulting from its anatomical structure and physiology, as well as the presence of specific elements that, through the mechanisms of innate and adaptive immunity, provide homeostasis of the eyeball. This article reviews the defensive elements of individual eye structures: conjunctiva, cornea, lacrimal gland, anterior chamber of the eye, uvea, retina and eye-associated lymphoid tissue (EALT), where we distinguish a...

  10. Fetal Eye Movements on Magnetic Resonance Imaging

    Science.gov (United States)

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C.; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Objectives Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Methods Dynamic SSFP sequences were acquired in 72 singleton fetuses (17–40 GW, three age groups [17–23 GW, 24–32 GW, 33–40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. Results In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3–45%. Conclusions In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations. PMID:24194885

  11. Fetal eye movements on magnetic resonance imaging.

    Science.gov (United States)

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Dynamic SSFP sequences were acquired in 72 singleton fetuses (17-40 GW, three age groups [17-23 GW, 24-32 GW, 33-40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3-45%. In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations.

  12. Qualidade da avaliação da acuidade visual realizada pelos professores do programa " Olho no olho" da cidade de Marília, SP Assessment of visual acuity evaluation performed by teachers of the "Eye in eye" program in Marília-SP, Brazil

    Directory of Open Access Journals (Sweden)

    Lígia Issa De Fendi

    2008-08-01

    Full Text Available OBJETIVOS: Avaliar a qualidade e o ponto de corte (AV PURPOSE: To assess quality and cut-off point (VA <0.7 of the examinations performed by teachers to detect reduced visual acuity (VA in schoolchildren participants of the project called "Eye in eye " in Marilia-SP, Brazil. METHODS: Visual acuity measurements were performed by trained teachers using Snellen's chart. The children with VA <0.7 in one of the eyes were referred to an ophthalmic examination. The ophthalmic examination was considered gold standard to assess quality and cut-off point of the examinations performed by teachers. VA test was performed in 604 schoolchildren of state public schools (1,208 eyes. Analyses were based on examined eyes. We calculated sensitivity (S, specificity (E, positive predictive value (PPV, negative predictive value (NPV and likelihood rate (LR. We compared the means obtained by the teachers' examinations to means of the ophthalmologist's examinations. ROC curve was produced to evaluate whether VA lower than 0.7 is the best value for referral to an ophthalmic examination. RESULTS: VA means obtained by teachers and ophthalmologic examinations were 0.70 ± 0.16 and 0.88 ± 0.2 respectively. The difference between teachers' and ophthalmologists' examinations was 0.18 (p<0.0001. S, E, PPV, NPV e LR were: 82%, 40%, 27%, 89% and 1.37, respectively. False positive and negative rates were 59.5% and 18%. ROC curve evidenced that visual acuity of 0.7 was the best cut-off point to refer schoolchildren to an ophthalmic exam. CONCLUSIONS: We demonstrated the importance of the teachers' participation in improved schoolchildren ocular health. The examination performed by teachers obtained a satisfactory S with low E, NPV and high values of false positive results. The best cut-off point to refer schoolchildren to an ophthalmic examination was VA of 0.7.

  13. The all seeing eye?

    NARCIS (Netherlands)

    Koenderink, Jan J.

    2014-01-01

    The All Seeing Eye? Did you know that you are probably a believer in the All Seeing Eye? The odds are that I’m right—why? Well, the bulk of mainstream vision literature blindly relies on the All Seeing Eye. It is written all over papers, albeit between the lines. Understandably so, for scientists

  14. About the Eye

    Medline Plus

    Full Text Available ... other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and ...

  15. Dwarf Eye Disorder

    Science.gov (United States)

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  16. Fish eye optics

    Science.gov (United States)

    Hudec, R.; Michalova, S.

    2017-07-01

    We report on small student (high—school) project of the Czech Academy of Sciences dealing with animal (fish) eyes and possible application in science and technology. Albeit most fishes have refractive eyes, the recent discoveries confirm that some fishes have reflective eyes with strange arrangements as well.

  17. Eye and orbital cavity

    International Nuclear Information System (INIS)

    Panfilova, G.V.; Koval', G.Yu.

    1984-01-01

    Radioanatomy of eyes and orbit is described. Diseases of the orbit (developmental anomalies, inflammatory diseases, lacrimal apparatus deseases, toxoplasmosis, tumors and cysts et al.), methods of foreign body localization in the eye are considered. Roentgenograms of the orbit and calculation table for foreign body localization in spherical eyes of dissimilar diameter are presented

  18. Clinical Evaluation of a Royal Jelly Supplementation for the Restoration of Dry Eye: A Prospective Randomized Double Blind Placebo Controlled Study and an Experimental Mouse Model

    Science.gov (United States)

    Inoue, Sachiko; Kawashima, Motoko; Hisamura, Ryuji; Imada, Toshihiro; Izuta, Yusuke; Nakamura, Shigeru; Ito, Masataka; Tsubota, Kazuo

    2017-01-01

    Background Dry eye is a multifactorial disease characterized by ocular discomfort and visual impairment. Lacrimal gland function has been shown to decrease with aging, a known potent risk factor for dry eye. We have previously found that orally administrated royal jelly (RJ) restored tear secretion in a rat model of dry eye. Methods and Findings We examined the effects of RJ oral administration on dry eye in this prospective, randomized, double-blind, placebo-controlled study. Forty-three Japanese patients aged 20–60 years with subjective dry eye symptoms were randomized to an RJ group (1200 mg/tablet, six tablets daily) or a placebo group for 8 weeks. Keratoconjunctival epithelial damage, tear film break-up time, tear secretion volume, meibum grade, biochemical data, and subjective dry eye symptoms based on a questionnaire were investigated at baseline, and at 4 and 8 weeks after intervention. Adverse events were reported via medical interviews. In the RJ group, tear volume significantly increased after intervention (p = 0.0009). In particular, patients with a baseline Schirmer value of ≤10 mm showed a significant increase compared with baseline volume (p = 0.0005) and volume in the placebo group (p = 0.0051). No adverse events were reported. We also investigated the effect of RJ (300 mg/kg per day) administration using a mouse model of dry eye. Orally repeated administration of RJ preserved tear secretion, potentially through direct activation of the secretory function of the lacrimal glands. Conclusion Our results suggest that RJ improves tear volume in patients with dry eye. Trial Registration Registered NO. the University Hospital Medical Information Network in Japan (UMIN000014446) PMID:28060936

  19. Clinical Evaluation of a Royal Jelly Supplementation for the Restoration of Dry Eye: A Prospective Randomized Double Blind Placebo Controlled Study and an Experimental Mouse Model.

    Science.gov (United States)

    Inoue, Sachiko; Kawashima, Motoko; Hisamura, Ryuji; Imada, Toshihiro; Izuta, Yusuke; Nakamura, Shigeru; Ito, Masataka; Tsubota, Kazuo

    2017-01-01

    Dry eye is a multifactorial disease characterized by ocular discomfort and visual impairment. Lacrimal gland function has been shown to decrease with aging, a known potent risk factor for dry eye. We have previously found that orally administrated royal jelly (RJ) restored tear secretion in a rat model of dry eye. We examined the effects of RJ oral administration on dry eye in this prospective, randomized, double-blind, placebo-controlled study. Forty-three Japanese patients aged 20-60 years with subjective dry eye symptoms were randomized to an RJ group (1200 mg/tablet, six tablets daily) or a placebo group for 8 weeks. Keratoconjunctival epithelial damage, tear film break-up time, tear secretion volume, meibum grade, biochemical data, and subjective dry eye symptoms based on a questionnaire were investigated at baseline, and at 4 and 8 weeks after intervention. Adverse events were reported via medical interviews. In the RJ group, tear volume significantly increased after intervention (p = 0.0009). In particular, patients with a baseline Schirmer value of ≤10 mm showed a significant increase compared with baseline volume (p = 0.0005) and volume in the placebo group (p = 0.0051). No adverse events were reported. We also investigated the effect of RJ (300 mg/kg per day) administration using a mouse model of dry eye. Orally repeated administration of RJ preserved tear secretion, potentially through direct activation of the secretory function of the lacrimal glands. Our results suggest that RJ improves tear volume in patients with dry eye. Registered NO. the University Hospital Medical Information Network in Japan (UMIN000014446).

  20. Recognizing and Treating Eye Injuries

    Science.gov (United States)

    ... Eye Injuries First Aid for Eye Scratches Protective Eyewear Children’s Eye Injuries: Prevention and Care Eye Injuries ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  1. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  2. Parental knowledge and attitude to children's eye care services ...

    African Journals Online (AJOL)

    Background: The early years of life is very significant in the development of the eyes and vision, any disruption at this stage may lead to severe visual impairment or even blindness. Eye examination and treatment of children is not just a right of the child, but also a necessity to properly monitor and evaluate the eyes and ...

  3. Clinical evaluation of a dose monitoring software tool based on Monte Carlo Simulation in assessment of eye lens doses for cranial CT scans

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Forsting, Michael; Theysohn, Jens; Wetter, Axel; Ringelstein, Adrian [University Hospital Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany)

    2016-10-15

    The aim of this study was to verify the results of a dose monitoring software tool based on Monte Carlo Simulation (MCS) in assessment of eye lens doses for cranial CT scans. In cooperation with the Federal Office for Radiation Protection (Neuherberg, Germany), phantom measurements were performed with thermoluminescence dosimeters (TLD LiF:Mg,Ti) using cranial CT protocols: (I) CT angiography; (II) unenhanced, cranial CT scans with gantry angulation at a single and (III) without gantry angulation at a dual source CT scanner. Eye lens doses calculated by the dose monitoring tool based on MCS and assessed with TLDs were compared. Eye lens doses are summarized as follows: (I) CT angiography (a) MCS 7 mSv, (b) TLD 5 mSv; (II) unenhanced, cranial CT scan with gantry angulation, (c) MCS 45 mSv, (d) TLD 5 mSv; (III) unenhanced, cranial CT scan without gantry angulation (e) MCS 38 mSv, (f) TLD 35 mSv. Intermodality comparison shows an inaccurate calculation of eye lens doses in unenhanced cranial CT protocols at the single source CT scanner due to the disregard of gantry angulation. On the contrary, the dose monitoring tool showed an accurate calculation of eye lens doses at the dual source CT scanner without gantry angulation and for CT angiography examinations. The dose monitoring software tool based on MCS gave accurate estimates of eye lens doses in cranial CT protocols. However, knowledge of protocol and software specific influences is crucial for correct assessment of eye lens doses in routine clinical use. (orig.)

  4. Clinical evaluation of a dose monitoring software tool based on Monte Carlo Simulation in assessment of eye lens doses for cranial CT scans

    International Nuclear Information System (INIS)

    Guberina, Nika; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Forsting, Michael; Theysohn, Jens; Wetter, Axel; Ringelstein, Adrian

    2016-01-01

    The aim of this study was to verify the results of a dose monitoring software tool based on Monte Carlo Simulation (MCS) in assessment of eye lens doses for cranial CT scans. In cooperation with the Federal Office for Radiation Protection (Neuherberg, Germany), phantom measurements were performed with thermoluminescence dosimeters (TLD LiF:Mg,Ti) using cranial CT protocols: (I) CT angiography; (II) unenhanced, cranial CT scans with gantry angulation at a single and (III) without gantry angulation at a dual source CT scanner. Eye lens doses calculated by the dose monitoring tool based on MCS and assessed with TLDs were compared. Eye lens doses are summarized as follows: (I) CT angiography (a) MCS 7 mSv, (b) TLD 5 mSv; (II) unenhanced, cranial CT scan with gantry angulation, (c) MCS 45 mSv, (d) TLD 5 mSv; (III) unenhanced, cranial CT scan without gantry angulation (e) MCS 38 mSv, (f) TLD 35 mSv. Intermodality comparison shows an inaccurate calculation of eye lens doses in unenhanced cranial CT protocols at the single source CT scanner due to the disregard of gantry angulation. On the contrary, the dose monitoring tool showed an accurate calculation of eye lens doses at the dual source CT scanner without gantry angulation and for CT angiography examinations. The dose monitoring software tool based on MCS gave accurate estimates of eye lens doses in cranial CT protocols. However, knowledge of protocol and software specific influences is crucial for correct assessment of eye lens doses in routine clinical use. (orig.)

  5. A clinical study of the efficacy of topical corticosteroids on dry eye

    OpenAIRE

    Yang, Chong-qing; Sun, Wen; Gu, Yang-shun

    2006-01-01

    Objective: To evaluate the effect of topical corticosteroid for treatment of moderate or severe dry eye. Methods: Sixty eyes of 30 patients with moderate or severe dry eye, who were not sensitive to artificial tears, were treated with 0.1% fluorometholone eye drops. Subjective symptom and objective tests were used to evaluate the efficacy of treatment before and after application of 0.1% fluorometholone eye drops for 1 week and 1 month. Side effects were also evaluated. Results: After 1 week ...

  6. EyeMusic: Making Music with the Eyes

    OpenAIRE

    Hornof, Anthony J.; Sato, Linda

    2004-01-01

    Though musical performers routinely use eye movements to communicate with each other during musical performances, very few performers or composers have used eye tracking devices to direct musical compositions and performances. EyeMusic is a system that uses eye movements as an input to electronic music compositions. The eye movements can directly control the music, or the music can respond to the eyes moving around a visual scene. EyeMusic is implemented so that any composer using established...

  7. Genetic analyses of the human eye colours using a novel objective method for eye colour classification

    DEFF Research Database (Denmark)

    Andersen, Jeppe D.; Johansen, Peter; Harder, Stine

    2013-01-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically...... and TYR rs1393350) on the eye colour. We evaluated the two published prediction models for eye colour (IrisPlex [1] and Snipper[2]) and compared the predictions with the PIE-scores. We found good concordance with the prediction from individuals typed as HERC2 rs12913832 G. However, both methods had......-score ranged from −1 to 1 (brown to blue). The software eliminated the need for user based interpretation and qualitative eye colour categories. In 94% (570) of 605 analyzed eye images, the iris region was successfully extracted and a PIE-score was calculated. A very high correlation between the PIE...

  8. Coping with dry eyes: a qualitative approach.

    Science.gov (United States)

    Yeo, Sharon; Tong, Louis

    2018-01-16

    Dry eye is a common problem that affects many people worldwide, reducing quality of life and impacting daily activities. A qualitative approach often used in medicine and other disciplines is used to evaluate how people with dry eye cope with this impact. Six focus group sessions were conducted at the Singapore National Eye Centre (SNEC), premises of an eye research institute. These focus groups consist of a spectrum of dry eye sufferers (30 women, 8 men, aged 61 ± 11.8 years). Standard methods of coding followed by determination of themes were adhered to. Where classification was difficult, consensus was made between 3 assessors. Audio-recorded transcripts were coded in 10 themes by 3 assessors independently. Four of the themes involved traditional measures such as lid warming, cleansing, lubrication and oral dietary supplements. The other themes discovered were Traditional Chinese Medicine, modification of eye-care habits (e.g. wearing sunglasses), environmental humidity, lifestyle (e.g. sleeping habits), psychological attitude, and lastly sharing and communication. Holistic coping strategies were found to be prominent in dry eye sufferers from these focus groups, and people tend to find personalised ways of coping with the impact of dry eye on daily living.

  9. Eye Disease and Development

    DEFF Research Database (Denmark)

    Andersen, Thomas Barnebeck; Dalgaard, Carl-Johan Lars; Selaya, Pablo

    This research advances the hypothesis that cross-country variation in the historical incidence of eye disease has influenced the current global distribution of per capita income. The theory is that pervasive eye disease diminished the incentive to accumulate skills, thereby delaying the fertility...... transition and the take-off to sustained economic growth. In order to estimate the influence from eye disease incidence empirically, we draw on an important fact from the field of epidemiology: Exposure to solar ultraviolet B radiation (UVB-R) is an underlying determinant of several forms of eye disease...

  10. Inflammation in dry eye.

    Science.gov (United States)

    Stern, Michael E; Pflugfelder, Stephen C

    2004-04-01

    Dry eye is a condition of altered tear composition that results from a diseased or dysfunctional lacrimal functional unit. Evidence suggests that inflammation causes structural alterations and/or functional paralysis of the tear-secreting glands. Changes in tear composition resulting from lacrimal dysfunction, increased evaporation and/or poor clearance have pro-inflammatory effects on the ocular surface. This inflammation is responsible in part for the irritation symptoms, ocular surface epithelial disease, and altered corneal epithelial barrier function in dry eye. Anti-inflammatory therapies for dry eye target one or more of the inflammatory mediators/pathways that have been identified in dry eye.

  11. LASIK eye surgery

    Science.gov (United States)

    ... Assisted In Situ Keratomileusis; Laser vision correction; Nearsightedness - Lasik; Myopia - Lasik ... cornea (curvature) and the length of the eye. LASIK uses an excimer laser (an ultraviolet laser) to ...

  12. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics ... Services Advocacy Foundation About Subspecialties & More Eye ...

  13. Prevention of Eye Injuries

    OpenAIRE

    Pashby, Tom

    1981-01-01

    In Canada 30,000 people are registered as blind; in one third of these, blindness might have been avoided. Prevention is the key to reducing the number of eye injuries and blind eyes. The role of the family physician in early identification of treatable conditions and in the education of patients is discussed, but responsibility for prevention belongs to all physicians. The success of prevention is seen in the great reduction in eye injuries in industry and sports since eye protectors have be...

  14. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ...

  15. EyeAR: Refocusable Augmented Reality Content through Eye Measurements

    Directory of Open Access Journals (Sweden)

    Damien Constantine Rompapas

    2017-09-01

    Full Text Available Augmented Reality (AR superimposes computer graphics (CG onto a user’s view of the real world. A key quality problem in this field is to achieve coherence between reality and CG when the user’s eyes refocus or change pupil size. We designed and evaluated a display that improves coherence by measuring the user’s eye state and continuously adapting CG accordingly. Our tabletop prototype emulates an Optical See-Through Head-Mounted Display, a common AR display device. In our evaluation, participants observed three pillars at different depths. We then challenged them to identify a virtual pillar among the three while freely refocusing their eyes. Results show that our design significantly improved realism. Compared to Light Field Displays, our design aims to simplify display-optics while providing similar quality. We could only partially achieve this goal. We discuss the lessons we learned and how we plan to overcome the remaining challenges. The experimental protocol from our evaluation is useful for display developers as it can be used to measure the coherence of a display.

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines ... Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines ...

  17. Eye tracking social preferences

    NARCIS (Netherlands)

    Jiang, Ting; Potters, Jan; Funaki, Yukihiko

    We hypothesize that if people are motivated by a particular social preference, then choosing in accordance with this preference will lead to an identifiable pattern of eye movements. We track eye movements while subjects make choices in simple three-person distribution experiments. We characterize

  18. XI. THE WATERING EYE

    African Journals Online (AJOL)

    cause a watering eye; this condition is.called epiphora. Clearly, then, in investigating ... blockage is a common disease in the middle age-groups seen in hospital .... a dry eye, and this is so much worse than a wet one that the procedure is only ...

  19. Dry eye syndrome

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000426.htm Dry eye syndrome To use the sharing features on this page, ... second-hand smoke exposure Cold or allergy medicines Dry eye can also be caused by: Heat or ... Symptoms may include: Blurred vision Burning, itching, ...

  20. What Is Dry Eye?

    Medline Plus

    Full Text Available ... is also when your eyes do not make the right type of tears or tear film . How do tears work? When you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and ...

  1. Photorefraction of the Eye

    Science.gov (United States)

    Colicchia, Giuseppe; Wiesner, Hartmut; Zollman, Dean

    2015-01-01

    Photorefraction is a method to easily estimate the refractive state of the eye. The principle of photorefraction involves projecting light into the eye during flash photography and then examining the paths of light that emerge from the pupil after scattering on the back portion of the interior of the eyeball (fundus). We will explain the optical…

  2. Lasik eye surgery - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100206.htm Lasik eye surgery - series—Normal anatomy To use the ... A.M. Editorial team. Related MedlinePlus Health Topics Laser Eye Surgery A.D.A.M., Inc. is accredited by ...

  3. About the Eye

    Medline Plus

    Full Text Available ... luh) is the small, sensitive area of the retina needed for central vision. It contains the fovea. Lens is the clear part of the eye behind the iris that helps to focus light on the retina. It allows the eye to focus on both ...

  4. LASIK Eye Surgery

    Science.gov (United States)

    ... at the front of your eye — to improve vision. Normally, images are clearly focused on the retina in the back of your eye because the ... sharply, light rays focus in front of the retina and blur distant vision. You can see objects that are close fairly ...

  5. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and ...

  6. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job ... Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job ...

  7. What Is Dry Eye?

    Medline Plus

    Full Text Available ... also when your eyes do not make the right type of tears or tear film . How do tears work? When you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and clear. The tear film is important for good vision. The tear film is made of three ...

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society ... Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society ...

  9. Smoking and Eye Health

    Science.gov (United States)

    ... Patient Stories Español Eye Health / Tips & Prevention Sections Smoking and Eye Disease Leer en Español: El cigarrillo ... By: Brenda Pagan-Duran MD Apr. 27, 2017 Smoking contributes to a number of major health problems, ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive ... Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive ...

  11. About the Eye

    Medline Plus

    Full Text Available ... Learn how the different parts of your eye work together so you can see and make sense of the world around you. Did You Know? Vision depends on your brain as much as it does on your eyes. NEI Home Contact Us A-Z Site Map NEI on ...

  12. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Media Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare ... Media Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare ...

  13. BullsEye

    DEFF Research Database (Denmark)

    Klokmose, Clemens Nylandsted; Kristensen, Janus Bager; Bagge, Rolf

    2014-01-01

    implemented primarily in shaders on the GPU. The techniques are realized in the BullsEye computer vision software. We demonstrate experimentally that BullsEye provides sub-pixel accuracy down to a tenth of a pixel, which is a significant improvement compared to the commonly used reacTIVision software....

  14. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum ... Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and ... Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare ... Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America Help IRIS Registry Medicare ...

  17. What Is Dry Eye?

    Medline Plus

    Full Text Available ... bloodshot when I wake up? Jun 26, 2016 Why are my eyes dry after LASIK? Jun 19, 2016 Can I be tested whether I close my eyes when I sleep? Feb 10, 2016 Can light sensitivity from Parkinson’s ...

  18. Apoptosis in the eye.

    OpenAIRE

    Chahory , Sabine; Torriglia , Alicia

    2006-01-01

    Apoptosis is a normal component of the development and health of multicellular organisms. Cells die during apoptosis in a controlled, regulated fashion. This form of cell death is very important in eye development as well as in eye pathology. We review in this chapter our current knowledge in this topic.

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America ... Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools and Services EyeCare America ...

  20. Eyes, Bulging (Proptosis)

    Science.gov (United States)

    ... Early Breast Cancer to Avoid Chemo Could a Blood Test Spot Lung Cancer Early? Experimental Drug Shows 'Modest' Benefit ... often done when bulging affects only one eye. Blood tests to measure how well the thyroid is working are done when ... When bulging leads to severe dry eyes, lubrication with artificial tears is needed to ...

  1. Different cellular effects of four anti-inflammatory eye drops on human corneal epithelial cells: independent in active components

    OpenAIRE

    Qu, Mingli; Wang, Yao; Yang, Lingling; Zhou, Qingjun

    2011-01-01

    Purpose To evaluate and compare the cellular effects of four commercially available anti-inflammatory eye drops and their active components on human corneal epithelial cells (HCECs) in vitro. Methods The cellular effects of four eye drops (Bromfenac Sodium Hydrate Eye Drops, Pranoprofen Eye Drops, Diclofenac Sodium Eye Drops, and Tobramycin & Dex Eye Drops) and their corresponding active components were evaluated in an HCEC line with five in vitro assays. Cell proliferation and migration were...

  2. Sappinia sp. (Amoebozoa: Thecamoebida) and Rosculus sp. (SAR: Cercozoa) Isolated From King Penguin Guano Collected in the Subantarctic (South Georgia, Salisbury Plain) and their Coexistence in Culture.

    Science.gov (United States)

    Tyml, Tomáš; Dyková, Iva

    2018-01-16

    Two amoeboid organisms of the genera Sappinia Dangeard, 1896 and Rosculus Hawes, 1963 were identified in a sample containing king penguin guano. This sample, collected in the Subantarctic, enlarges the list of fecal habitats known for the presence of coprophilic amoebae. The two organisms were co-isolated and subcultured for over 6 mo, with continuous efforts being invested to separate each one from the mixed culture. In the mixed culture, Rosculus cells were fast growing, tolerated changes in culturing conditions, formed cysts, and evidently were attracted by Sappinia trophozoites. The separation of the Rosculus strain was accomplished, whereas the Sappinia strain remained intermixed with inseparable Rosculus cells. Sappinia cell populations were sensitive to changes in culturing conditions; they improved with reduction of Rosculus cells in the mixed culture. Thick-walled cysts, reportedly formed by Sappinia species, were not seen. The ultrastructure of both organisms was congruent with the currently accepted generic characteristics; however, some details were remarkable at the species level. Combined with the results of phylogenetic analyses, our findings indicate that the ultrastructure of the glycocalyx and the presence/absence of the Golgi apparatus in differential diagnoses of Sappinia species require a critical re-evaluation. © 2018 The Author(s) Journal of Eukaryotic Microbiology © 2018 International Society of Protistologists.

  3. Causes of Red Eye-Uveitis

    OpenAIRE

    Selçuk Sızmaz

    2012-01-01

    Uveitis, being an important cause of ocular morbidity, must be taken into consideration in the differential diagnosis and the management of patients with red eye. Uveitis entities can demonstrate variable clinical features. Patients presenting with uveitis must undergo careful systemic evaluation for exact diagnosis and treatment. Studies for standardization of uveitis with variable clinical pictures are emerging. Acute anterior uveitis and panuveitis can cause red eye. The purpose o...

  4. Evolution and the Calcite Eye Lens

    OpenAIRE

    Williams, Vernon L.

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  5. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes

    OpenAIRE

    Erçalık, Nimet Yeşim; İmamoğlu, Serhat

    2018-01-01

    Purpose. To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. Materials and Methods. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical...

  6. In vivo evaluation and in-depth pharmaceutical characterization of a rapidly dissolving solid ocular matrix for the topical delivery of timolol maleate in the rabbit eye model.

    Science.gov (United States)

    Moosa, Raeesa M; Choonara, Yahya E; du Toit, Lisa C; Tomar, Lomas K; Tyagi, Charu; Kumar, Pradeep; Carmichael, Trevor R; Pillay, Viness

    2014-05-15

    The purpose of this study was to investigate the in-depth pharmaceutical properties and in vivo behavior of a novel lyophilized rapidly dissolving solid ocular matrix (RD-SOM) as a 'solid eye drop' formulation comprising timolol maleate as the model drug. Thermal and molecular transition analysis displayed similar findings with no incompatibility between formulation components. Porositometric studies confirmed the presence of interconnecting pores across the matrix surface. The HETCAM test indicated an irritation score of 0 with the inference of good tolerability for the RD-SOM in the New Zealand White albino rabbit eye model. Ex vivo permeation across excised rabbit cornea showed an improved steady state drug flux (0.00052 mg cm(-2)min(-1)) and permeability co-efficient (1.7 × 10(-4)cmmin(-1)) for the RD-SOM compared to pure drug and a marketed eye drop preparation. UPLC analysis quantitatively separated timolol maleate and the internal standard (diclofenac sodium) and gamma irradiation was used as a terminal sterilization procedure. In vivo results revealed a peak concentration of timolol was reached at 104.9 min. In the case of a typical eye drop formulation a lower Cmax was obtained (1.97 ug/mL). Level A point-to-point IVIVC plots via the Wagner-Nelson method revealed a satisfactory R(2) value of 0.84. In addition, the biodegradability and ocular compatibility of the RD-SOM was confirmed by histopathological toxicity studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. SIDRE: Symptomatic Improvement of Dry Eye Study

    Directory of Open Access Journals (Sweden)

    De Paz CJ

    2017-03-01

    Full Text Available Clarissa J De Paz, Agustin L Gonzalez, Chi Ngo Eye & Vision, Richardson, TX, USA Purpose: The aim of this study was to evaluate the effectiveness of lifitegrast 5% ophthalmic solution in reducing the symptoms of eye dryness using Ocular Surface Disease Index (OSDI questionnaire. Methods: A single-center study was undertaken to evaluate the clinical outcomes. Fourteen subjects (12 female and 2 male with symptoms of dry eye and a positive history of recent use of artificial tears were included in the study. OSDI questionnaire scores on the severity of symptoms, visual functionality, and quality of life related to the condition were recorded pre- and post-therapy. Subsequently, score data were analyzed for statistical significance. Results: The mean age of the 14 subjects was 44.86 (standard deviation [SD] ±3.08 years, with a range of 23–62 years. Mean duration of the evaluation was 28.79 days with a range of 25–34 days. Baseline OSDI mean score was 49.40 (SD ±1.28, and post-therapy mean score was 42.26 (SD ±0.99. Data analysis revealed that the scores were statistically significantly improved post-lifitegrast therapy in comparison to baseline (p=0.00041. Conclusion: Lifitegrast 5% ophthalmic solution may be a beneficial therapeutic option in the management of symptoms associated with dry eye disease. Keywords: dry eye disease, ocular surface disease, dry eye treatment, lifitegrast

  8. Advocacy for eye care

    Directory of Open Access Journals (Sweden)

    Thulasiraj D Ravilla

    2012-01-01

    Full Text Available The effectiveness of eye care service delivery is often dependant on how the different stakeholders are aligned. These stakeholders range from the ministries of health who have the capacity to grant government subsidies for eye care, down to the primary healthcare workers who can be enrolled to screen for basic eye diseases. Advocacy is a tool that can help service providers draw the attention of key stakeholders to a particular area of concern. By enlisting the support, endorsement and participation of a wider circle of players, advocacy can help to improve the penetration and effectiveness of the services provided. There are several factors in the external environmental that influence the eye care services - such as the availability of trained manpower, supply of eye care consumables, government rules and regulations. There are several instances where successful advocacy has helped to create an enabling environment for eye care service delivery. Providing eye care services in developing countries requires the support - either for direct patient care or for support services such as producing trained manpower or for research and dissemination. Such support, in the form of financial or other resources, can be garnered through advocacy.

  9. Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with 125I seeds (model I25.S16)

    International Nuclear Information System (INIS)

    Acar, Hilal; Chiu-Tsao, Sou-Tung; Özbay, İsmail; Kemikler, Gönül; Tuncer, Samuray

    2013-01-01

    Purpose: (1) To measure absolute dose distributions in eye phantom for COMS eye plaques with 125 I seeds (model I25.S16) using radiochromic EBT film dosimetry. (2) To determine the dose correction function for calculations involving the TG-43 formalism to account for the presence of the COMS eye plaque using Monte Carlo (MC) method specific to this seed model. (3) To test the heterogeneous dose calculation accuracy of the new version of Plaque Simulator (v5.3.9) against the EBT film data for this seed model. Methods: Using EBT film, absolute doses were measured for 125 I seeds (model I25.S16) in COMS eye plaques (1) along the plaque's central axis for (a) uniformly loaded plaques (14–20 mm in diameter) and (b) a 20 mm plaque with single seed, and (2) in off-axis direction at depths of 5 and 12 mm for all four plaque sizes. The EBT film calibration was performed at 125 I photon energy. MC calculations using MCNP5 code for a single seed at the center of a 20 mm plaque in homogeneous water and polystyrene medium were performed. The heterogeneity dose correction function was determined from the MC calculations. These function values at various depths were entered into PS software (v5.3.9) to calculate the heterogeneous dose distributions for the uniformly loaded plaques (of all four sizes). The dose distributions with homogeneous water assumptions were also calculated using PS for comparison. The EBT film measured absolute dose rate values (film) were compared with those calculated using PS with homogeneous assumption (PS Homo) and heterogeneity correction (PS Hetero). The values of dose ratio (film/PS Homo) and (film/PS Hetero) were obtained. Results: The central axis depth dose rate values for a single seed in 20 mm plaque measured using EBT film and calculated with MCNP5 code (both in ploystyrene phantom) were compared, and agreement within 9% was found. The dose ratio (film/PS Homo) values were substantially lower than unity (mostly between 0.8 and 0.9) for all

  10. Aquaporins in the Eye

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Hamann, Steffen; Heegaard, Steffen

    2017-01-01

    The major part of the eye consists of water . Continuous movement of water and ions between the ocular compartments and to the systemic circulation is pivotal for many physiological functions in the eye. The movement of water facilitates removal of the many metabolic products of corneal-, ciliary...... pressure. In the retina, water is transported into the vitreous body and across the retinal pigment epithelium to regulate the extracellular environment and the hydration of the retina. Aquaporins (AQPs ) take part in the water transport throughout the eye....

  11. Acidic mammalian chitinase in dry eye conditions.

    Science.gov (United States)

    Musumeci, Maria; Aragona, Pasquale; Bellin, Milena; Maugeri, Francesco; Rania, Laura; Bucolo, Claudio; Musumeci, Salvatore

    2009-07-01

    An acidic mammalian chitinase (AMCase) seems to be implicated in allergic asthma and allergic ocular pathologies. The aim of this work was to investigate the role of AMCase during Sjögren's Syndrome (SS) and Meibomian Gland Dysfunction (MGD) dry eye diseases. Six patients with MGD dry eye (20-58 years, median 40) and six patients with dry eye associated to SS (32-60 years, median 47) were enrolled in this study. AMCase activity was measured in tears and AMCase mRNA expression was evaluated by real-time polymerase chain reaction from RNA extracted from epithelial cells of the conjunctiva. Six healthy adult subjects of the same age (34-44 years, median 39) were also studied as the control group. AMCase activity was significantly increased in patients affected by MGD dry eye (18.54 +/- 1.5 nmol/ml/h) and SS dry eye (8.94 +/- 1.0 nmol/ml/h) respectively, compared to healthy controls (1.6 +/- 0.2 nmol/ml/h). AMCase activity was higher in the tears of subjects with MGD dry eye (P < 0.001). AMCase mRNA was detected in conjunctival epithelial cells and the expression was significantly higher in MGD dry eye than SS dry eye. A significant correlation between AMCase activity in the tears and mRNA in conjunctival epithelial cells was found. AMCase may be an important marker in the pathogenesis of dry eye, suggesting the potential role of AMCase as a therapeutic target in these frequent pathologies.

  12. Dry eye syndrome in thyroid-associated ophthalmopathy

    Directory of Open Access Journals (Sweden)

    A. F. Brovkina

    2015-01-01

    Full Text Available Purpose: The pathogenesis of keratoconjunctivitis sicca in patients with thyroid eye disease is presented. The influence of therapy by a HYLO-PARIN® on a condition of a tear film in patients with various forms of thyroid eye disease is assessed. Methods: 34 eyes (17 patients with thyroid eye disease were investigated. Dry eye evaluations included Shirmer and Jhones testing, tear film break-up time, corneal fluorescein staining. Patients were treated with HYLOPARIN ® (Ursapharm, Germany.Results: Study showed that HYLO-PARIN® resulted in marked improvement as assessed by subjective complaints, Schirmer’s test, tear film break-up test.Conclusion: HYLO-PARIN® provided relief from the signsand symptoms of dry eye syndrome at patients with various forms of thyroid eye disease.

  13. Dry eye syndrome in thyroid-associated ophthalmopathy

    Directory of Open Access Journals (Sweden)

    A. F. Brovkina

    2014-01-01

    Full Text Available Purpose: The pathogenesis of keratoconjunctivitis sicca in patients with thyroid eye disease is presented. The influence of therapy by a HYLO-PARIN® on a condition of a tear film in patients with various forms of thyroid eye disease is assessed. Methods: 34 eyes (17 patients with thyroid eye disease were investigated. Dry eye evaluations included Shirmer and Jhones testing, tear film break-up time, corneal fluorescein staining. Patients were treated with HYLOPARIN ® (Ursapharm, Germany.Results: Study showed that HYLO-PARIN® resulted in marked improvement as assessed by subjective complaints, Schirmer’s test, tear film break-up test.Conclusion: HYLO-PARIN® provided relief from the signsand symptoms of dry eye syndrome at patients with various forms of thyroid eye disease.

  14. PSS32 Impact of dry eye on everyday life (Ideel) - Symptom bother: Estimating cut-off scores for dry eye severity groups

    OpenAIRE

    Acaster, S.; Verboven, Y.; Begley, C.; Chalmers, R.; Abetz, L.; Thompson, T.

    2011-01-01

    The aims of the study were to estimate score ranges associated with dry eye severity based on the Impact of Dry Eye on Everyday Life (IDEEL) Symptom Bother (SB) domain, and to evaluate the overall performance of the SB domain.

  15. About the Eye

    Medline Plus

    Full Text Available ... programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and ... It sends electrical impulses through the optic nerve to the brain. Watch ...

  16. Diabetic Eye Problems

    Science.gov (United States)

    ... damage your eyes. The most common problem is diabetic retinopathy. It is a leading cause of blindness ... You need a healthy retina to see clearly. Diabetic retinopathy damages the tiny blood vessels inside your ...

  17. About the Eye

    Medline Plus

    Full Text Available ... of many different parts that work together to help you see. Check out the diagrams below to ... part of the eye behind the iris that helps to focus light on the retina. It allows ...

  18. About the Eye

    Medline Plus

    Full Text Available ... to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of the blind.” ... Clinical Studies Publications Catalog Photos ...

  19. About the Eye

    Medline Plus

    Full Text Available ... Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables ... Optic nerve (OP-tic nurv) is the bundle of more than 1 million nerve fibers that carry visual messages from the retina to ...

  20. What Is Dry Eye?

    Medline Plus

    Full Text Available ... month dissolvable punctal plug be removed or pushed down the tear duct to insert a permanent punctal ... Your Eyelid Nov 29, 2017 New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  1. About the Eye

    Medline Plus

    Full Text Available ... the Scientific Director Office of the Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical ... System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear ...

  2. Eye Involvement in TSC

    Science.gov (United States)

    ... 50% of the individuals with TSC have normal intelligence, and inasmuch as these individuals may become parents, ... of vision may be difficult or impossible. Since growth and change of TSC lesions in the eye ...

  3. What Is Dry Eye?

    Medline Plus

    Full Text Available ... EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Museum of Vision Ophthalmology Job Center ... Ophthalmology Guide Find an Ophthalmologist Advanced Search Annual Meeting Clinical Education Practice Management Member Services Advocacy Foundation ...

  4. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for ...

  5. Amblyopia: Lazy Eye Treatment

    Science.gov (United States)

    ... with Myopia Aug 31, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 Combating ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  6. Amblyopia: Lazy Eye Diagnosis

    Science.gov (United States)

    ... with Myopia Aug 31, 2017 Eye Injuries from Laundry Packets On the Rise Jun 30, 2017 Combating ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  7. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  8. About the Eye

    Medline Plus

    Full Text Available ... the NEI Website search NEI on Social Media | Search A-Z | en español | Text size S M L ... (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to ...

  9. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips ... addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... of tears or tear film . How do tears work? When you blink, a film of tears spreads ... Get ophthalmologist-reviewed tips and information about eye health and preserving your vision. Privacy Policy Related Please ...

  11. What Is Dry Eye?

    Medline Plus

    Full Text Available ... treated? Jan 28, 2016 Find an Ophthalmologist Advanced Search Ask an Ophthalmologist Browse Answers Free Newsletter Get ophthalmologist-reviewed tips and information about eye health and preserving your vision. Privacy ...

  12. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., Scientific Director David ...

  13. About the Eye

    Medline Plus

    Full Text Available ... Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs ... Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and ...

  14. About the Eye

    Medline Plus

    Full Text Available ... Contact Us Visiting the NIH Campus Mission Statement As part of the federal government’s National Institutes of ... Did You Know? Vision depends on your brain as much as it does on your eyes. NEI ...

  15. About the Eye

    Medline Plus

    Full Text Available ... NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to ... for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media ...

  16. About the Eye

    Medline Plus

    Full Text Available ... about each part of your eye and what it does. Macula (MACK-yoo-luh) is the small, ... area of the retina needed for central vision. It contains the fovea. Lens is the clear part ...

  17. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Academy Publications EyeNet Ophthalmology Ophthalmology Retina Information for: International Ophthalmologists Media Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists Young Ophthalmologists Tools ...

  18. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis ... Eye Health A-Z Symptoms Glasses & Contacts Tips & ...

  19. About the Eye

    Medline Plus

    Full Text Available ... Office of the Scientific Director Office of the Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the ...

  20. Using Eye Makeup

    Science.gov (United States)

    ... harmful chemicals. Before applying makeup, be sure your face and eyelids are very clean. Always apply makeup outside the lash line, away from the eye, to avoid blocking the oil glands of the upper or lower ...

  1. About the Eye

    Medline Plus

    Full Text Available ... Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science Programs Division ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ...

  2. About the Eye

    Medline Plus

    Full Text Available ... of visual function, preservation of sight, and the special health problems and requirements of the blind.” News & ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  3. About the Eye

    Medline Plus

    Full Text Available ... part of your eye and what it does. Macula (MACK-yoo-luh) is the small, sensitive area ... FOH-vee-uh) is the center of the macula, where your vision is sharpest. Optic nerve (OP- ...

  4. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology Ophthalmology Retina Information for: International Ophthalmologists ...

  5. About the Eye

    Medline Plus

    Full Text Available ... 5248 Health Information Frequently asked questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  6. About the Eye

    Medline Plus

    Full Text Available ... Office of the Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research ... iris adjusts the size of the pupil and controls the amount of light that can enter the ...

  7. About the Eye

    Medline Plus

    Full Text Available ... System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear ... Social Media Policies and Other Important Links NEI Employee Emergency Information NEI Intranet (Employees Only) *PDF files ...

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... information about eye health and preserving your vision. Privacy Policy Related Please Don’t Shave the Inside ... the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media ...

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Uveitis Focus On Pediatric Ophthalmology Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global ... an Ophthalmologist Patient Stories Español Eye Health / ...

  10. What Is Dry Eye?

    Medline Plus

    Full Text Available ... of tears or tear film . How do tears work? When you blink, a film of tears spreads ... eyes don’t make enough tears or something affects one or more layers of the tear film. ...

  11. About the Eye

    Medline Plus

    Full Text Available ... Learn how the different parts of your eye work together so you can see and make sense of the world around you. ... Social Media Policies and Other Important Links NEI Employee Emergency Information ...

  12. About the Eye

    Medline Plus

    Full Text Available ... Campus Mission Statement As part of the federal government’s National Institutes of Health (NIH), the National Eye ... Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science ...

  13. About the Eye

    Medline Plus

    Full Text Available ... are made up of many different parts that work together to help you see. Check out the diagrams ... Learn how the different parts of your eye work together so you can see and make sense of ...

  14. Eye Injuries at Home

    Science.gov (United States)

    ... by the Numbers — Infographic Five Steps to Safer Champagne Celebrations Eye Injuries at Home Leer en Español: ... that can splatter hot grease or oil. Opening champagne bottles during a celebration. Drilling or hammering screws ...

  15. About the Eye

    Medline Plus

    Full Text Available ... are made up of many different parts that work together to help you see. Check out the ... Learn how the different parts of your eye work together so you can see and make sense ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Care, Part 5 Mar 19, 2013 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry ...

  17. About the Eye

    Medline Plus

    Full Text Available ... History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  18. Fish eye optics

    Czech Academy of Sciences Publication Activity Database

    Hudec, René; Michalová, S.

    2017-01-01

    Roč. 47, č. 2 (2017), s. 94-99 ISSN 1335-1842. [INTEGRAL/BART Workshop /14./. Karlovy Vary, 03.04.2017-07.04.2017] Grant - others:GA ČR(CZ) GA13-33324S Institutional support: RVO:67985815 Keywords : fish eye optics * lobster eye optics * X-ray monitoring Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics OBOR OECD: Astronomy (including astrophysics,space science) Impact factor: 0.336, year: 2016

  19. Knowledge, Attitude, and Practice of Dry Eye Treatment by Institutional Chinese Physicians in Singapore

    OpenAIRE

    Lan, Wanwen; Lee, Sze Yee; Lee, Man Xin; Tong, Louis

    2012-01-01

    Dry eye is a common health problem worldwide, causing significant discomfort and inconvenience to sufferers. The conventional treatment of dry eye via topical administration of eye drops is deemed palliative and unsatisfactory to many. Traditional Chinese medicine (TCM) has shown some promise in dry eye treatment; however, the extent of its use and acceptance is uncertain. We evaluated the knowledge, attitude, and practice of institutional TCM practitioners in the treatment of dry eye in Sing...

  20. Danish Rural Eye Study

    DEFF Research Database (Denmark)

    Høeg, Tracy Beth; Ellervik, Christina; Buch, Helena

    2016-01-01

    , Danish Rural Eye Study (DRES). All DRES participants received a comprehensive general health examination preceding their eye examination, including measurement of best-corrected visual acuity (BCVA) for each eye, bilateral 45° retinal fundus photographs and further ophthalmological examination where...... indicated. RESULTS: Overall, 3826 of 3843 participants (99.6%) had bilateral visual acuity measurements. The overall frequency of VI (BCVA eye) was 0.4% (95% confidence interval, CI, 0.2-0.7%; n = 15) among all DRES participants, 0.6% (95% CI 0.3-1.0%; n = 15) among participants...... >50 years and 3.7% (95% CI 2.1-6.5%; n = 11) in participants >80 years. The primary causes of VI in the better-seeing eye were age-related macular degeneration (AMD) in 46.7% (7/15) and cataract in 26.7% (4/15). A total of 43.3% (n = 115) of participants >80 years were pseudophakic in one or both eyes...

  1. New Eye Cleansing Product Improves Makeup-Related Ocular Problems.

    Science.gov (United States)

    Okura, Masako; Kawashima, Motoko; Katagiri, Mikiyuki; Shirasawa, Takuji; Tsubota, Kazuo

    2015-01-01

    Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.

  2. New Eye Cleansing Product Improves Makeup-Related Ocular Problems

    Directory of Open Access Journals (Sweden)

    Masako Okura

    2015-01-01

    Full Text Available Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.

  3. Pink Eye: What To Do

    Centers for Disease Control (CDC) Podcasts

    In this podcast, CDC's Adam Cohen, MD, a pediatrician and parent, discusses conjunctivitis (pink eye), a common eye condition in children and adults. He reviews pink eye causes and treatment, suggestions on when to call or visit a doctor, and practical tips to prevent pink eye from spreading.

  4. Identification system by eye retinal pattern

    International Nuclear Information System (INIS)

    Sunagawa, Takahisa; Shibata, Susumu

    1987-01-01

    Identification system by eye retinal pattern is introduced from the view-point of history of R and D, measurement, apparatus, evaluation tests, safety and application. According to our evaluation tests, enrolling time is approximately less than 1 min, verification time is a few seconds and false accept rate is 0 %. Evaluation tests at Sandia National Laboratories in USA show the comparison data of false accept rates such as 0 % for eye retinal pattern, 10.5 % for finger-print, 5.8 % for signature dynamics and 17.7 % for speaker voice. The identification system by eye retinal pattern has only three applications in Japan, but there has been a number of experience in USA. This fact suggests that the system will become an important means for physical protections not only in nuclear field but also in other industrial fields in Japan. (author)

  5. Intravitreal injection analysis at the Bascom Palmer Eye Institute: evaluation of clinical indications for the treatment and incidence rates of endophthalmitis

    Directory of Open Access Journals (Sweden)

    Ludimila L Cavalcante

    2010-05-01

    Full Text Available Ludimila L Cavalcante, Milena L Cavalcante, Timothy G Murray, Michael M Vigoda, Yolanda Piña, Christina L Decatur, R Prince Davis, Lisa C Olmos, Amy C Schefler, Michael B Parrott, Kyle J Alliman, Harry W Flynn, Andrew A MoshfeghiBascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, FL, USAObjective: To report the incidence of endophthalmitis, in addition to its clinical and microbiological aspects, after intravitreal injection of vascular-targeting agents.Methods: A retrospective review of a consecutive series of 10,142 intravitreal injections of vascular targeting agents (bevacizumab, ranibizumab, triamcinolone acetonide, and preservative-free triamcinolone acetonide between June 1, 2007 and January 31, 2010, performed by a single service (TGM at the Bascom Palmer Eye Institute.Results: One case of clinically-suspected endophthalmitis was identified out of a total of 10,142 injections (0.009%, presenting within three days of injection of bevacizumab. The case was culture-positive for Staphylococcus epidermidis. Final visual acuity was 20/40 after pars plana vitrectomy surgery.Conclusions: In this series, the incidence of culture-positive endophthalmitis after intravitreal injection of vascular agents in an outpatient setting was very low. We believe that following a standardized injection protocol, adherence to sterile techniques and proper patient follow-up are determining factors for low incidence rates.Keywords: endophthalmitis, intravitreal injections, vascular targeting agents 

  6. Functional magnetic resonance imaging of the frontal eye fields during saccadic eye movements

    International Nuclear Information System (INIS)

    Miki, Atsushi; Takagi, Mineo; Abe, Haruki; Nakajima, Takashi; Miyauchi, Satoru.

    1996-01-01

    We evaluated activity-induced signal intensity changes in the human cerebral cortex during horizontal saccadic eye movements using functional magnetic resonance imaging (fMRI) based on the blood-oxygenation-level-dependent (BOLD) contrast method. Compared with central fixation, significant signal increases were observed bilaterally in the middle frontal gyrus (Brodmann area 8) during saccadic conditions. The location of the activated area was consistent with that of previously reported frontal eye fields (FEF). These results suggest that fMRI has potential merit for the study of cortical control of eye movements in humans. (author)

  7. NASA's "Eyes" Focus on Education

    Science.gov (United States)

    Hussey, K.

    2016-12-01

    NASA's "Eyes on…" suite of products continues to grow in capability and popularity. The "Eyes on the Earth", "Eyes on the Solar System" and "Eyes on Exoplanets" real-time, 3D interactive visualization products have proven themselves as highly effective demonstration and communication tools for NASA's Earth and Space Science missions. This presentation will give a quick look at the latest updates to the "Eyes" suite plus what is being done to make them tools for STEM Education.

  8. Radiation dose to the eye lens

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; D. Nielsen, Kamilla

    2015-01-01

    Radiation Dose to the Eye Lens: Does Positioning Really Matter? C. Baun1, K. Falch1, K.D. Nielsen2, S. Shanmuganathan1, O. Gerke1, P.F. Høilund-Carlsen1 1Department of Nuclear Medicine, Odense University Hospital, Odense C, Denmark. 2University College Lillebaelt, Odense, Denmark. Aim: The scan...... field in oncology patients undergoing eyes-to-thighs PET/CT must always include the base of the scull according to department guidelines. The eye lens is sensitive to radiation exposure and if possible it should be avoided to scan the eye. If the patient’s head is kipped backwards during the scan one...... might avoid including the eye in the CT scan without losing sufficient visualization of the scull base. The aim of this study was to evaluate the possibility of decreasing the radiation dose to the eye lens, simply by changing the head position, when doing the PET/CT scan from the base of the scull...

  9. An optomechanical model eye for ophthalmological refractive studies.

    Science.gov (United States)

    Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa

    2013-02-01

    To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.

  10. Evaluation of host rocks and background lithologies as secondary contributors to the uranium and rare-earth element source-term at the Needle's Eye natural analogue site

    International Nuclear Information System (INIS)

    Hyslop, E.K.

    1993-01-01

    HMIP has a research programme investigating some naturally radioactive sites in the UK as geochemical analogues of radionuclide migration. The objective is to test thermodynamic database and computer codes used for modelling radionuclide migration under environmental conditions. This report describes a study of the distributions of uranium (U) and the rare-earth elements (REE) in the vicinity of pitchblende veins outcropping in the cliff at Needle's Eye on the Solway Coats, SW Scotland. This report improves the information available on the secondary source-terms of U and REE. The minerals in the country rocks are thought to be supplying only minor amounts of these elements to the groundwaters flowing into the Merse silts within the detailed study area close to the mineralisation in the cliff. The pitchblende veins are the principal source-term for U migrating into the Merse silts at the foot of the cliff. (author)

  11. Efficacy of punctal occlusion in management of dry eyes after laser in situ keratomileusis for myopia.

    Science.gov (United States)

    Alfawaz, Abdullah M; Algehedan, Saeed; Jastaneiah, Sabah S; Al-Mansouri, Samir; Mousa, Ahmed; Al-Assiri, Abdullah

    2014-03-01

    To evaluate the effect of punctal plug use in preventing dry eye after laser in situ keratomileusis (LASIK). A randomized clinical trial at a tertiary eye care center, Riyadh, Saudi Arabia. Participants underwent LASIK for myopia in both eyes and a lower punctal occlusion in one eye only while the other eye served as control. Both eyes received the same postoperative medications except for lubricant duration (subject eye: four times per day for one week; control eye: four times per day for 6 months). Participants were evaluated at 1 week, 2, and 6 months after surgery for signs and symptoms of dry eye. The main outcome measures were visual acuity; ocular surface parameters; and Ocular Surface Disease Index questionnaire. Seventy-eight eyes of 39 patients were included in this study. The Ocular Surface Disease Index scores of eyes with punctal plugs were better at all follow-up visits, and the differences between both eyes were statistically significant (1 week, p eyes was higher in eyes with punctal plugs for all ocular surface parameters (Schirmer 1 test, 94.9%; tear breakup time, 77.8%; punctate epithelial keratitis score, 71.8%) compared to eyes without occlusion (Schirmer 1 test, 92.3%; tear breakup time, 58.3%; punctate epithelial keratitis score, 53.8%); however, such differences were not statistically significant. Punctal plug insertion after LASIK surgeries may minimize the need for frequent lubricant application and hence improve patient satisfaction.

  12. King and Eye

    DEFF Research Database (Denmark)

    Suwannakij, Sing

    King and Eye explores the visual formation of kingship in Siam in its multifarious aspects. This dissertation identifies the leitmotifs in the dynamics between seeing the king and being seen by him, which burst forth in different eras. The visual sense has been a repository for the ontologization...... devices, most significantly the photographic and the cine cameras, but also encompassing other ocular apparatuses. The images produced through the contraptions were brought together under the royal eye at the apex, which in turn claimed its supremacy over space, time, and the vast and diverse population...

  13. Danish Rural Eye Study

    DEFF Research Database (Denmark)

    Høeg, Tracy B; Moldow, Birgitte; Ellervik, Christina

    2015-01-01

    and older from a Danish rural municipality received a complete general health examination and an ophthalmological interview and examination. This study included a comprehensive ophthalmologic interview, measurement of best corrected visual acuity (BCVA) in each eye, Hirschberg's test for strabismus and two...... 45-degree retinal fundus photographs of each eye. A complete ophthalmologic examination was performed when indicated. RESULTS: The prevalence of monocular visual impairment (MVI) was 4.26% (95% CI, 3.66-4.95, n = 163). Amblyopia was the most common cause, accounting for 33%. The prevalence...

  14. Corneal permeability changes in dry eye disease: an observational study.

    Science.gov (United States)

    Fujitani, Kenji; Gadaria, Neha; Lee, Kyu-In; Barry, Brendan; Asbell, Penny

    2016-05-13

    Diagnostic tests for dry eye disease (DED), including ocular surface disease index (OSDI), tear breakup time (TBUT), corneal fluorescein staining, and lissamine staining, have great deal of variability. We investigated whether fluorophotometry correlated with previously established DED diagnostic tests and whether it could serve as a novel objective metric to evaluate DED. Dry eye patients who have had established signs or symptoms for at least 6 months were included in this observational study. Normal subjects with no symptoms of dry eyes served as controls. Each eye had a baseline fluorescein scan prior to any fluorescein dye. Fluorescein dye was then placed into both eyes, rinsed with saline solution, and scanned at 5, 10, 15, and 30 min. Patients were administered the following diagnostic tests to correlate with fluorophotometry: OSDI, TBUT, fluorescein, and lissamine. Standard protocols were used. P eyes from 25 patients (DED = 22 eyes, 11 patients; Normal = 28 eyes, 14 patients) were included. Baseline scans of the dry eye and control groups did not show any statistical difference (p = 0.84). Fluorescein concentration of DED and normal patients showed statistical significance at all time intervals (p eyes up to 30 min after fluorescein dye instillation. There may be an aspect of DED that is missed in the current regimen of DED tests and only captured with fluorophotometry. Adding fluorophotometry may be useful in screening, diagnosing, and monitoring patients with DED.

  15. Ready-made allogeneic ABO-specific serum eye drops

    DEFF Research Database (Denmark)

    Harritshøj, Lene Holm; Nielsen, Connie; Ullum, Henrik

    2014-01-01

    serum treatment. CONCLUSION: Ready-made ABO-identical allogeneic serum eye drops were straightforwardly produced, quality-assured and registered as a safe standard blood product for the treatment of certain cases of severe dry eye disease. Therapeutic efficacy was comparable to previous reports......PURPOSE: To overcome problems and delays of the preparation of autologous serum eye drops, a production line of ABO-specific allogeneic serum eye drops from male blood donors was set up in a blood bank. Feasibility, clinical routine, safety and efficacy were evaluated in a cohort of patients...

  16. Dry Eye Management: Targeting the Ocular Surface Microenvironment.

    Science.gov (United States)

    Zhang, Xiaobo; M, Vimalin Jeyalatha; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo; Li, Wei

    2017-06-29

    Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment.

  17. Dry Eye Management: Targeting the Ocular Surface Microenvironment

    Science.gov (United States)

    Zhang, Xiaobo; Jeyalatha M, Vimalin; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo

    2017-01-01

    Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment. PMID:28661456

  18. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  19. Effect of lipid-based dry eye supplements on the tear film in wearers of eye cosmetics.

    Science.gov (United States)

    Wang, Michael T M; Cho, Irene Sung Hee; Jung, Soo Hee; Craig, Jennifer P

    2017-08-01

    To compare the effects on tear film parameters and contamination in cosmetic eyeliner wearers, after single application of two lipid-based dry eye treatments: a lipid-containing lubricant eye drop and a phospholipid liposomal spray. Fifty participants were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. Pencil eyeliner (Body Shop ® Crayon Eye Definer) was applied to the upper eyelid periocular skin of both eyes, anterior to the lash line. Baseline tear film quality was assessed fifteen minutes after eyeliner application. A lubricant drop (Systane ® Balance) was then applied to one eye (randomised), and liposomal spray (Tears Again ® ) to the contralateral eye. Tear film contamination, lipid layer grade, non-invasive tear film break-up time and tear evaporation rate were evaluated fifteen minutes post-treatment and compared to pre-treatment values. Pre-treatment measurements did not differ between eyes assigned to lubricant drop and liposomal spray. Tear film contamination was observed in a greater proportion of eyes following both treatments (both p0.05). Changes in tear film parameters did not differ between treatments (all p>0.05). Both the lipid-containing lubricant eye drop and phospholipid liposomal spray result in clinically apparent tear film contamination in eyeliner cosmetic wearers. Although both treatments effected an increase in lipid layer thickness, neither displayed clinical efficacy in improving tear film stability. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Knowledge, Attitude and Practice of Eye Health Care amongst ...

    African Journals Online (AJOL)

    Objective: To evaluate the knowledge, attitude and practice of eye health care amongst doctors in Lagos. Methodology: Open and closed-ended questionnaires were given to respondents. The questionnaire contained information about age, sex, general knowledge as well as practice of eye care. Results: A total of 104 ...

  1. Specialized moisture retention eyewear for evaporative dry eye.

    Science.gov (United States)

    Waduthantri, Samanthila; Tan, Chien Hua; Fong, Yee Wei; Tong, Louis

    2015-05-01

    To evaluate the suitablity of commercially available moisture retention eyewear for treating evaporative dry eye. Eleven patients with evaporative dry eyes were prescibed moisture retention eyewear for 3 months in addition to regular lubricant eye drops. Frequency and severity of dry eye symptoms, corneal fluorescein staining and tear break up time (TBUT) were evaluated at baseline and 3-month post-treatment. Main outcome measure was global symptom score (based on severity and frequency of dry eye symptoms on a visual analog scale) and secondary outcomes were changes in sectoral corneal fluorescein staining and tear break up time (TBUT) from pre-treatment level. There was a significant improvement in dry eye symptoms after using moisture retention eyewear for 3 months (p eyes improved significantly (p dry eye symptoms in windy, air-conditioned environments or when doing vision-related daily tasks. This study shows that moisture retention eyewear might be a valuable adjunct in management of evaporative dry eye and this new design of commercially available eyewear could have a good acceptability rate.

  2. The influence of protein free calf blood extract eye gel on dry eye after pterygium surgery

    Directory of Open Access Journals (Sweden)

    Cai-Ni Ji

    2013-07-01

    Full Text Available AIM: To investigate the influence of protein free calf blood extract eye gel on dry eye after pterygium surgery. METHODS: Thirty six patients(40 eyeswith primary nasal pterygium were enrolled in this study, which were divided into study group and control group randomly, with 20 eyes in each group. All patients received pterygium excision and limbal stem cell autograft surgery and tobramicin dexamethasone eye drops after surgery. Patients of the study group received protein free calf blood extract eye gel while those of the control group received 0.1% sodium hyaluronate eye drops furthermore. Ocular surface disease index(OSDIquestionnaire, tear film break-up time(BUTand Schirmer's Ⅰ test Ⅰ(SⅠtwere carried before and 3 months after surgery to evaluate the dry eye degree of the patients. RESULTS: There was no statistical difference between the age, gender and size of the pterygium of the study and control groups preoperatively. There was no statistical difference between the OSDI(2.33±1.02 vs 2.32±0.93, BUT(8.80±2.48 vs 8.35±2.28seconds and SⅠt(4.30±2.30 vs 4.40±2.44of the two groups preoperatively. There was statistical difference between the OSDI(1.45±0.47 vs 1.81±0.60, BUT(11.20±2.07 vs 9.50±2.40seconds and SⅠt(8.35±3.13 vs 6.35±2.18of the two groups 3 months postoperatively, which was also different from that of the preoperative data correspondingly. CONCLUSION: Protein free calf blood extract eye gel could reduce the dry eye after pterygium surgery.

  3. About the Eye

    Medline Plus

    Full Text Available ... programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and ... is the center of the macula, where your vision is sharpest. Optic nerve (OP-tic nurv) is the bundle of more than 1 ...

  4. Eye Injuries in Construction

    Science.gov (United States)

    ... cold helps keep down pain and swelling. If pain continues or your vision is blurry, get to a doctor right away. ! If you get hit in the eye with flying metal, wood, or material from a power tool (like a drill or wheel) , OR ! If ...

  5. Robustifying eye interaction

    DEFF Research Database (Denmark)

    Hansen, Dan Witzner; Hansen, John Paulin

    2006-01-01

    This paper presents a gaze typing system based on consumer hardware. Eye tracking based on consumer hardware is subject to several unknown factors. We propose methods using robust statistical principles to accommodate uncertainties in image data as well as in gaze estimates to improve accuracy. We...

  6. About the Eye

    Medline Plus

    Full Text Available ... Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to the NEI Contact Us Visiting the NIH Campus Mission Statement As part ...

  7. About the Eye

    Medline Plus

    Full Text Available ... Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  8. About the Eye

    Medline Plus

    Full Text Available ... of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., ... David M. Schneeweis, Ph.D., Deputy Scientific Director Office of the Clinical Director Brian P. Brooks, M. ...

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... type of tears or tear film . How do tears work? When you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and clear. The tear film is important for good vision. The tear ...

  10. LASIK - Laser Eye Surgery

    Science.gov (United States)

    ... Refractive Surgery Procedures What Is Photorefractive Keratectomy (PRK)? LASIK — Laser Eye Surgery Leer en Español: LASIK—Cirugía ocular con láser ... loss of close-up focusing power. How the LASIK procedure works LASIK is performed while the patient ...

  11. What Is Dry Eye?

    Medline Plus

    Full Text Available ... make the right type of tears or tear film . How do tears work? When you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and clear. The tear film is important for good vision. The tear film ...

  12. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety ... Employee Emergency Information NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. ...

  13. Eyes on the Road

    Centers for Disease Control (CDC) Podcasts

    One of the first lessons new drivers learn is to keep their eyes on the road. Unfortunately, cell phones and other electronic devices are causing many drivers to lose their focus, and sometimes their lives. In this podcast, Rebecca Naumann discusses the dangers of distracted driving.

  14. The Learned Eye

    NARCIS (Netherlands)

    Doel, van den Marieke; Eck, van Natasja; Korevaar, Gerbrand; Tummers, Anna; Weststeijn, Thijs

    2005-01-01

    The 'learned eye' or oculus eruditus was a concept used by seventeenth-century writers on painting. It illustrated their view that the ideal artist was not only skilled in painting techniques, but also had knowledge of the history of art and an interest in poetry and literature.In this book,

  15. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. This website is ...

  16. Laser photocoagulation - eye

    Science.gov (United States)

    ... an eye disorder that slowly destroys sharp, central vision A tear in the retina A blockage of the small veins that carry ... Since parts of the retina are burned, you may develop: Mild loss ... vision If not treated, diabetic retinopathy can cause permanent ...

  17. About the Eye

    Medline Plus

    Full Text Available ... with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ... Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  18. About the Eye

    Medline Plus

    Full Text Available ... to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of ... Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  19. Eye Cosmetic Safety

    Science.gov (United States)

    ... you're wearing? In the United States, the use of color additives is strictly regulated. A number of color ... to color additives that are not approved for use in the area of the eye. Avoid color additives that are not approved for use in ...

  20. About the Eye

    Medline Plus

    Full Text Available ... programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  1. About the Eye

    Medline Plus

    Full Text Available ... blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of the blind.” ... DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications ( ...

  2. About the Eye

    Medline Plus

    Full Text Available ... the white outer coating of the eye. Vitreous humor (VIT-ree-us HYOO-mer) is the clear ... in Spanish (Información en español) Website, Social Media Policies and Other Important Links NEI Employee Emergency Information ...

  3. Exploring the Predisposition of the Asian Eye to Development of Dry Eye.

    Science.gov (United States)

    Craig, Jennifer P; Wang, Michael T M; Kim, Dabin; Lee, Jung Min

    2016-07-01

    To investigate the influence of eyelid shape on tear film quality, ocular surface characteristics and dry eye symptomatology by comparing Asian and Caucasian populations. Seventy-four age-matched participants were recruited in a cross-sectional study. Participants were classified into Asian single lid (ASL), Asian double lid (ADL), and Caucasian double lid (CDL) groups. Dry eye symptomatology, ocular surface characteristics, and tear film quality were evaluated in a single clinical session. Meibomian gland dropout was significantly greater in both the ASL and ADL groups than in the CDL group (all Pdry eye symptomatology between the three groups (all P>.05). Exposed ocular surface area, lissamine green staining, and lid wiper epitheliopathy were significantly greater in the ADL group compared to the CDL group (all Pdry eye. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Quantitative assessment of manual and robotic microcannulation for eye surgery using new eye model.

    Science.gov (United States)

    Tanaka, Shinichi; Harada, Kanako; Ida, Yoshiki; Tomita, Kyohei; Kato, Ippei; Arai, Fumihito; Ueta, Takashi; Noda, Yasuo; Sugita, Naohiko; Mitsuishi, Mamoru

    2015-06-01

    Microcannulation, a surgical procedure for the eye that requires drug injection into a 60-90 µm retinal vein, is difficult to perform manually. Robotic assistance has been proposed; however, its effectiveness in comparison to manual operation has not been quantified. An eye model has been developed to quantify the performance of manual and robotic microcannulation. The eye model, which is implemented with a force sensor and microchannels, also simulates the mechanical constraints of the instrument's movement. Ten subjects performed microcannulation using the model, with and without robotic assistance. The results showed that the robotic assistance was useful for motion stability when the drug was injected, whereas its positioning accuracy offered no advantage. An eye model was used to quantitatively assess the robotic microcannulation performance in comparison to manual operation. This approach could be valid for a better evaluation of surgical robotic assistance. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Development of the New Zealand White Rabbit Eye: I. Pre- and Postnatal Development of Eye Tunics.

    Science.gov (United States)

    Abdo, M; Haddad, S; Emam, M

    2017-10-01

    The New Zealand white (NZW) rabbit has been and is right now regularly utilized in ophthalmic surgery evaluation. Inside NZW rabbit eye, the visibility of ocular structures throughout surgical procedure is fantastic. Younger rabbits are used in different ages for the evaluation of ophthalmic surgery. Complete studies of ocular development in the NZW rabbits have not been reported previously. The aim of the present investigation was to describe the major landmarks and the time course of the pre- and post-natal development of the complete eye tunics of the NZW rabbit to give a superb model as well as a fruitful area for further ophthalmological investigations. Serial histological sections of NZW rabbit prenatal (E13-E28) and post-natal (P1-P14) stages were examined, respectively. The eye of the NZW rabbit developed in a similar manner to that of the human and domestic animals eyes; the principal differences were at the time of occurrence of certain developmental events, absence of pigmentation which represent an exploited benefit for ophthalmic surgery, remarkable Bowman's membrane at E25, poor developed ciliary stroma and juvenile retinal layer until P9. In human, the basic morphogenetic processes of the development of eye tunics are completed towards the end of the first half of gestation period. However, the latter represents the beginning stage of the development of eye tunics in the rabbit. Thus, allowing various extensive ophthalmic researches to be performed. © 2017 Blackwell Verlag GmbH.

  6. Using an eye tracker for accurate eye movement artifact correction

    NARCIS (Netherlands)

    Kierkels, J.J.M.; Riani, J.; Bergmans, J.W.M.; Boxtel, van G.J.M.

    2007-01-01

    We present a new method to correct eye movement artifacts in electroencephalogram (EEG) data. By using an eye tracker, whose data cannot be corrupted by any electrophysiological signals, an accurate method for correction is developed. The eye-tracker data is used in a Kalman filter to estimate which

  7. Allergic conjunctivitis and dry eye syndrome.

    Science.gov (United States)

    Hom, Milton M; Nguyen, Andrew L; Bielory, Leonard

    2012-03-01

    Allergic conjunctivitis (AC) and dry eye syndrome (DES) are 2 of the most common anterior inflammatory disorders of the ocular surface and one does not preclude the coexistence of the other. To examine the potential overlap between AC and DES as comorbidities. Using the validated questionnaire known as Subjective Evaluation of Symptom of Dryness, we studied self-reported itchiness, dryness, and redness. In an outpatient optometric setting, 689 patients treated from January 1, 2007, to January 1, 2011, were surveyed for their ocular history and categorized according to their reported level of discomfort of itchiness, dryness, and redness. Patients ranged in age from 5 to 90 years (median age, 25 years; 39.5% male; 60.5% female). In the studied 689 patients, clinically significant itchiness was found in 194 (28.2%), dry eyes in 247 (35.8%), and redness in 194 (28.2%). Symptom overlap was demonstrated in many of the patients. Of the 194 patients with itchiness, 112 (57.7%) had clinically significant dryness. In the 247 patients with dry eyes, 112 (45.3%) had clinically significant itch. Redness was apparent in 120 of the 194 patients with itch (61.9%) and 122 of the 247 patients with dryness (49.4%). Statistical analysis demonstrated that self-reported itchiness, dryness, and redness were not independent of each other (Peyes" also experiencing dry eyes were 2.11 times and the odds of these patients also experiencing redness were 7.34 times that of patients with nonitchy eyes. Most patients with "itchy eyes" consistent with AC also have dry eyes and redness. These results suggest that some symptomatic patients concomitantly have features of AC and DES. Copyright © 2012 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  8. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2018-01-01

    Full Text Available Purpose. To evaluate the outcomes of Ahmed glaucoma valve (AGV implantation in vitrectomized eyes. Materials and Methods. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP, best-corrected visual acuity (BCVA, number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. Results. The mean follow-up duration was 11.7 ± 5.5 (range, 6–23 months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg (p=0.001 and the mean number of glaucoma medications decreased to 2.3 ± 1.3 (p=0.021. At the last visit, 11 eyes (84.4% had stable or improved VA and one eye (7.7% had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%. Postoperative complications were bleb encapsulation (69.2%, early hypotony (38.5%, hyphema (23.1%, decompression retinopathy (23.1%, choroidal detachment (15.4%, intraocular hemorrhage (7.7%, and late endophthalmitis (7.7%. One eye (7.7% was enucleated because of late endophthalmitis. Conclusions. Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation.

  9. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes.

    Science.gov (United States)

    Erçalık, Nimet Yeşim; İmamoğlu, Serhat

    2018-01-01

    To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. The mean follow-up duration was 11.7 ± 5.5 (range, 6-23) months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg ( p =0.001) and the mean number of glaucoma medications decreased to 2.3 ± 1.3 ( p =0.021). At the last visit, 11 eyes (84.4%) had stable or improved VA and one eye (7.7%) had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%). Postoperative complications were bleb encapsulation (69.2%), early hypotony (38.5%), hyphema (23.1%), decompression retinopathy (23.1%), choroidal detachment (15.4%), intraocular hemorrhage (7.7%), and late endophthalmitis (7.7%). One eye (7.7%) was enucleated because of late endophthalmitis. Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation.

  10. Conjunctivitis (Pink Eye) in Newborns

    Science.gov (United States)

    ... as well as the sexually transmitted infection called gonorrhea. Women with untreated gonorrhea can pass the bacteria to her baby during ... conjunctivitis is less common than conjunctivitis caused by gonorrhea and chlamydia. Symptoms usually include red eye(s) and ...

  11. Causes of Red Eye-Uveitis

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2012-12-01

    Full Text Available Uveitis, being an important cause of ocular morbidity, must be taken into consideration in the differential diagnosis and the management of patients with red eye. Uveitis entities can demonstrate variable clinical features. Patients presenting with uveitis must undergo careful systemic evaluation for exact diagnosis and treatment. Studies for standardization of uveitis with variable clinical pictures are emerging. Acute anterior uveitis and panuveitis can cause red eye. The purpose of this current study is to summarize the clinical features and laboratory investigations that could help the differential diagnosis of acute anterior uveitis and panuveitis cases. (Turk J Ophthalmol 2012; 42: Supplement 57-62

  12. Pink Eye: What To Do

    Centers for Disease Control (CDC) Podcasts

    2010-10-12

    In this podcast, CDC's Adam Cohen, MD, a pediatrician and parent, discusses conjunctivitis (pink eye), a common eye condition in children and adults. He reviews pink eye causes and treatment, suggestions on when to call or visit a doctor, and practical tips to prevent pink eye from spreading.  Created: 10/12/2010 by National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 10/13/2010.

  13. Neuropathic pain and dry eye.

    Science.gov (United States)

    Galor, Anat; Moein, Hamid-Reza; Lee, Charity; Rodriguez, Adriana; Felix, Elizabeth R; Sarantopoulos, Konstantinos D; Levitt, Roy C

    2018-01-01

    Dry eye is a common, multifactorial disease currently diagnosed by a combination of symptoms and signs. Its epidemiology and clinical presentation have many similarities with neuropathic pain outside the eye. This review highlights the similarities between dry eye and neuropathic pain, focusing on clinical features, somatosensory function, and underlying pathophysiology. Implications of these similarities on the diagnosis and treatment of dry eye are discussed. Published by Elsevier Inc.

  14. Moving eyes and naming objects

    NARCIS (Netherlands)

    Meulen, F.F. van der

    2001-01-01

    The coordination between eye movements and speech was examined while speakers were naming objects. Earlier research has shown that eye movements reflect on the underlying visual attention. Also, eye movements were found to reflect upon not only the visual and conceptual processing of an object, but

  15. LIMNOLOGICAL OPTOMETRY: EXAMINING EARTH'S EYE

    Science.gov (United States)

    In Thoreau's Walden, a lake is described as the landscape's most expressive feature and the earth's eye. Collectively, scientists are charged by society to assess, monitor, and remedy maladies of earth's eye in the same way optometrists maintain the health of the human eye. This ...

  16. Eye Protection in Kansas Schools.

    Science.gov (United States)

    Hay, Kenneth M.; And Others

    A law passed by a state legislature requires that students in industrial arts shops and science laboratories must wear eye protective devices. Explanatory material presents the text of the bill and guidelines for implementation, including--(1) types of eye hazards, (2) types of protective devices, (3) administrating eye safety equipment, (4)…

  17. Quality of life of eye amputated patients

    DEFF Research Database (Denmark)

    Rasmussen, Marie L R; Ekholm, Ola; Prause, Jan U

    2011-01-01

    Purpose: To evaluate eye-amputated patients’ health-related quality of life, perceived stress, self-rated health, job separation because of illness or disability and socioeconomic position. Methods: Patients were recruited from a tertiary referral centre situated in Copenhagen. Inclusion criteria......-administered questionnaire containing health-related quality of life (SF-36), the perceived stress scale and answered questions about self-rated health, job changes because of illness or disability and socioeconomic status. These results were compared with findings from the Danish Health Interview Survey 2005. Results...... and self-rated health of many eye-amputated patients are drastically changed. Eye amputation has a marked negative influence on job separation because of illness or disability and on socioeconomic position....

  18. The highly myopic eye--oculometric considerations

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Goldschmidt, Ernst

    2012-01-01

    (n=39) in 1962. Clinical follow-up studies were conducted in 1976, 1986, 1995 and 2002, with A-scan ultrasound oculometry (Kretztechnik 7000, immersion method; and Sonometrics 400, contact method) as a regular part of the schedule. For comparison, IOL Master evaluations were added in 2002...... by Francois and Goes, not all long eyes have flat corneas. In our high myopia series, a significant subgroup could thus be discerned who had peaked corneas, which led to mathematically slight reduction of the usual positive correlation between axial length and curvature radius in the ametropia population......; and (d) we found positive correlation between myopia increase in adult age and axial elongation, stressing that, in contrast to other outgrown body structures, the adult eye globes may still expand in size. This feature seems to be found not only in the eyes with posterior staphyloma, but also in myopic...

  19. Evaluation of Accessory Lacrimal Gland in Muller's Muscle Conjunctival Resection Specimens for Precursor Cell Markers and Biological Markers of Dry Eye Disease.

    Science.gov (United States)

    Ali, Marwan; Shah, Dhara; Pasha, Zeeshan; Jassim, Sarmad H; Jassim Jaboori, Assraa; Setabutr, Pete; Aakalu, Vinay K

    2017-04-01

    The accessory lacrimal glands (ALGs) are an understudied component of the tear functional unit, even though they are important in the development of dry eye syndrome (DES). To advance our understanding of aging changes, regenerative potential, and histologic correlates to human characteristics, we investigated human ALG tissue from surgical samples to determine the presence or absence of progenitor cell markers and lacrimal epithelial markers and to correlate marker expression to relevant patient characteristics. ALG tissues obtained from Muller's muscle conjunctival resection (MMCR) specimens were created using tissue microarrays (TMAs). Immunofluorescence staining of MMCR sections was performed using primary antibodies specific to cell protein markers. Cell marker localization in TMAs was then assessed by two blinded observers using a standardized scoring system. Patient characteristics including age, race, and status of ocular surface health were then compared against expression of stem cell markers. Human ALG expressed a number of epithelial markers, and in particular, histatin-1 was well correlated with the expression of epithelial markers and was present in most acini. In addition, we noted the presence of precursor cell markers nestin, ABCG2, and CD90 in ALG tissue. There was a decrease in precursor cell marker expression with increasing age. Finally, we noted that a negative association was present between histatin-1 expression and DES. Thus, we report for the first time that human ALG tissues contain precursor marker-positive cells and that this marker expression may decrease with increasing age. Moreover, histatin-1 expression may be decreased in DES. Future studies will be performed to use these cell markers to isolate and culture lacrimal epithelial cells from heterogeneous tissues, determine the relevance of histatin-1 expression to DES, and isolate candidate precursor cells from ALG tissue.

  20. Evaluation of Accessory Lacrimal Gland in Muller’s Muscle Conjunctival Resection Specimens for Precursor Cell Markers and Biological Markers of Dry Eye Disease

    Science.gov (United States)

    Ali, Marwan; Shah, Dhara; Pasha, Zeeshan; Jassim, Sarmad H.; Jaboori, Assraa Jassim; Setabutr, Pete; Aakalu, Vinay K.

    2017-01-01

    Purpose The accessory lacrimal glands (ALG) are an understudied component of the tear functional unit, even though they are important in the development of dry eye syndrome (DES). To advance our understanding of aging changes, regenerative potential and histologic correlates to human characteristics, we investigated human ALG tissue from surgical samples to determine the presence or absence of progenitor cell markers and lacrimal epithelial markers and to correlate marker expression to relevant patient characteristics. Materials and Methods ALG tissues obtained from Muller’s Muscle Conjunctival Resection (MMCR) specimens were created using tissue microarrays (TMAs). Immunofluorescence staining of MMCR sections was performed using primary antibodies specific to cell protein markers. Cell marker localization in TMAs was then assessed by two blinded observers using a standardized scoring system. Patient characteristics including age, race, and status of ocular surface health were then compared against expression of stem cell markers. Results Human ALG expressed a number of epithelial markers, and in particular, histatin-1 was well correlated with the expression of epithelial markers and was present in most acini. In addition, we noted the presence of precursor cell markers nestin, ABCG2 and CD90 in ALG tissue. There was a decrease in precursor cell marker expression with increasing age. Finally, we noted that a negative association was present between histatin-1 expression and DES. Conclusions Thus, we report for the first time that human ALG tissues contain precursor marker positive cells and that this marker expression may decrease with increasing age. Moreover, histatin-1 expression may be decreased in DES. Future studies will be performed to use these cell markers to isolate and culture lacrimal epithelial cells from heterogeneous tissues, determine the relevance of histatin-1 expression to DES and isolate candidate precursor cells from ALG tissue. PMID:27612554

  1. Investigation of moxifloxacin loaded chitosan–dextran nanoparticles for topical instillation into eye: In-vitro and ex-vivo evaluation

    Science.gov (United States)

    Kaskoos, Raad A.

    2014-01-01

    Introduction: Management of ocular surface disease by conventional formulation is limited by poor residence of drug at cul-de-sac of eye. To overcome this limitation, prolonged released mucoadhesive chitosan (CS)–dextran sulfate (DS) nanoparticles (NPs) were investigated for the prolonged topical ophthalmic delivery of moxifloxacin (Mox). Methods: Formulation was optimized by 3-factors (CS, DS, and Mox concentration), 3-levels (−1, 0, +1) Box-Behnken design. Optimized formulation was characterized for various in-vitro attributes, including particles size, zeta potential, shape and morphology, in-vitro release profile, corneal permeation, corneal retention, ocular tolerance test as well as antimicrobial activity. Results: Average hydrodynamic particle size of statistically optimized formulation was found to be 279.18 ± 15.63 nm with good polydispersity index, 0.367 ± 0.016 and positive zeta potential, +31.23 ± 1.32. NPs showed entrapment efficiency, 72.82 ± 3.6% and transmission electron microscopic analysis revealed a spherical shape of particles. Formulation exhibited biphasic release profile with an initial fast release (≈25% in 1st h) followed by sustained release (≈95% in next 24 h) following Korsmeyer–Peppas model with a nonFickian diffusion process. Mox loaded CS-DS NPs exhibited a significantly higher (P < 0.01), approximately 1.8-fold transcorneal permeation as well as significantly higher corneal retention (P < 0.01), around 4-5-fold when compared to free solution. Developed formulation exhibited safety profile comparable to normal saline, which was revealed by ocular tolerance test (Hen's egg test-chorioallantoic membrane). Mox-CS-DS NPs exhibited significantly high (P < 0.01) antimicrobial activity against Staphylococcus aureus and Pseudomonas aeruginosa. Conclusion: In-vitro and ex-vivo studies revealed that developed formulation could be a potential substitute for prolonged topical ocular delivery. PMID:25426437

  2. Dry Eyes and Glaucoma: Double Trouble

    Science.gov (United States)

    ... Involved News About Us Donate In This Section Dry Eyes and Glaucoma: Double Trouble email Send this article ... eye disease bothers the patient more. What Causes Dry Eye Syndrome? Dry eye can be caused by many ...

  3. Complications of cataract surgery in eyes filled with silicone oil.

    Science.gov (United States)

    Kanclerz, Piotr; Grzybowski, Andrzej; Schwartz, Stephen G; Lipowski, Paweł

    2018-03-01

    The aim of the study was to evaluate complications of cataract surgery in eyes filled with silicone oil. This retrospective, noncomparative, consecutive case series analyzed medical files of patients with eyes filled with silicone oil undergoing cataract surgery. Phacoemulsification with posterior chamber intraocular lens implantation was conducted with or without concurrent silicone oil removal. In this study, 121 eyes of 120 patients were included. In 32 eyes (26.4%) with evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, silicone oil was removed prior to phacoemulsification through a pars plana incision and no cases of posterior capsular rupture occurred during the subsequent cataract surgery. In the remaining 89 eyes, phacoemulsification was performed with silicone oil in the vitreous cavity. In these eyes, the rate of posterior capsular rupture was 9/89 (10.1%) and the rate of silicone oil migration into the anterior chamber through an apparently intact posterior capsule was 5/89 (5.6%). In 94 eyes (77.7%), an intraocular lens was inserted into the capsular bag, in 3 eyes (2.5%) into the sulcus, and in 1 eye (0.8%) a transscleral suturing was performed. In this series, complications related to the silicone oil were not uncommon during cataract surgery. In the majority of patients without evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, cataract surgery and posterior chamber intraocular lens implantation were performed while leaving the silicone oil in place.

  4. Advancements in anti-inflammatory therapy for dry eye syndrome.

    Science.gov (United States)

    McCabe, Erin; Narayanan, Srihari

    2009-10-01

    The goal of this literature review is to discuss recent discoveries in the pathophysiology of dry eye and the subsequent evolution of diagnostic and management techniques. The mechanisms of various anti-inflammatory treatments are reviewed, and the efficacy of common pharmacologic agents is assessed. Anti-inflammatory therapy is evaluated in terms of its primary indications, target population, and utility within a clinical setting. The Medline PubMed database and the World Wide Web were searched for current information regarding dry eye prevalence, pathogenesis, diagnosis, and management. After an analysis of the literature, major concepts were integrated to generate an updated portrayal of the status of dry eye syndrome. Inflammation appears to play a key role in perpetuating and sustaining dry eye. Discoveries of inflammatory markers found within the corneal and conjunctival epithelium of dry eye patients have triggered recent advancements in therapy. Pharmacologic anti-inflammatory therapy for dry eye includes 2 major categories: corticosteroids and immunomodulatory agents. Fatty acid and androgen supplementation and oral antibiotics have also shown promise in dry eye therapy because of their anti-inflammatory effects. Anti-inflammatory pharmacologic agents have shown great success in patients with moderate to severe dry eye when compared with alternative treatment modalities. A deeper understanding of the link between inflammation and dry eye validates the utilization of anti-inflammatory therapy in everyday optometric practice.

  5. Treatment of contact lens related dry eye with antibacterial honey.

    Science.gov (United States)

    Wong, Daniel; Albietz, Julie M; Tran, Huan; Du Toit, Cimonette; Li, Anita Hui; Yun, Tina; Han, Jee; Schmid, Katrina L

    2017-12-01

    Contact lens induced dry eye affects approximately 50% of contact lens wearers. The aim was to assess the effects of Manuka (Leptospermum sp.) honey eye drops (Optimel, Melcare, Australia) on dry eye in contact lens wearers. The safety of the honey eye drops in contact lens wear and contact lens wearers' compliance were also evaluated. Prospective, randomised, cross over study, examiner masked, pilot treatment trial. Twenty-four participants aged 20 to 55 years with contact lens related dry eye were recruited and randomised to two treatment groups; 20 completed the study. One group used Optimel eye drops twice a day for two weeks followed by conventional lubricant (Systane Ultra, Alcon) therapy for two weeks; the other group completed the treatments in the reverse order. Before and after each treatment dry eye symptomology, ocular surface inflammation, and tear quantity and quality were assessed. Participants completed a daily log detailing their usage of treatments and any issues. Dry eye symptoms improved significantly after Optimel treatment. Patients with more severe symptoms at baseline showed a greater improvement in symptoms. No significant differences were observed in the objective signs of dry eye; presumably because of the short treatment duration. Seventy-five% of contact lens wearers reported good adherence to Optimel treatment and 95% reported no issues using this product. Optimel Eye Drops reduce the symptoms of dry eye in contact lens wearers and are safe to use. A longer treatment period to assess the effect on clinical signs of dry eye is required. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  6. Nutrition and the eye.

    Science.gov (United States)

    Congdon, N G; West, K P

    1999-12-01

    The topic "nutrition and the eye" cannot adequately be covered in a single review article; indeed, dozens of books and hundreds of articles have been written on the subject. This review concentrates on three areas in which specific nutrients are known or theorized to have a major impact on vision and the visual system: vitamin A deficiency; antioxidants and their proposed role in the prevention of age-related cataract and macular degeneration; and nutritional optic neuropathies, including those of the recent Cuban epidemic. In addition, this article touches on nutritional treatments that have been suggested for several less common eye diseases and, finally, considers several less prevalent conditions in which deficiency of or excess exposure to a particular nutrient has been associated with ocular pathology.

  7. Managing eye injuries

    Directory of Open Access Journals (Sweden)

    Dorothy Mutie

    2016-01-01

    Full Text Available Based on what you found during the eye examination, classify the injury as a non-mechanical injury (chemical or thermal injury, a non-globe injury (orbital or adnexal injury or as a mechanical globe injury. In the case of mechanical globe injuries, it is important to classify the injury according to the Birmingham Eye Trauma Terminology System (BETTS and write it down in the patient’s notes; this will help to ensure that everyone involved in caring for the patient will have a consistent understanding of the type of injury. The resulting uniformity of terminology also helps with research, making it possible to compare data and do audits of injuries – which is essential for prevention.

  8. Through the creator's eyes

    DEFF Research Database (Denmark)

    Glaveanu, Vlad Petre; Lahlou, Saadi

    2012-01-01

    of an adapted Subjective Evidence-Based Ethnography (SEBE). This methodology combines (a) obtaining first person audio-visual recordings of creative action with a miniature video-camera worn at eye-level, (b) accessing the subjective experience of the participant through a confrontation interview based...... of creativity at both process and content levels. The benefits, limitations, and possible applications of the method are considered in the broader context of creativity studies....

  9. Christoph Scheiner's eye studies.

    Science.gov (United States)

    Daxecker, F

    1992-01-01

    Christoph Scheiner was born in 1573 or 1575. In 1595 he entered into the Order of the Jesuits; he died in 1650. In 1619 his book Oculus, dealing with the optics of the eye, appeared in Innsbruck. The invention of the telescope was of utmost importance for progress in astronomical and physical research. Scheiner himself built telescopes and discovered the sunspots. As a result, an unpleasant priority dispute with Galilei ensued. From 1624 onwards, Scheiner was in Rome, where his main work Rosa Ursina was published in 1630. A part of this book deals with the physiological optics of the eye as well. Some of his discoveries and experiments are taken from these two books: determination of the radius of curvature of the cornea, discovery of the nasal exit of the optic nerve, increase in the radius of curvature of the lens in case of accommodation, Scheiner's procedure (double images with ametropia), refractive indices of various parts of the eye, Scheiner's experiment. Without any doubt, Christoph Scheiner belongs to the foremost scientists of the first half of the 17th century.

  10. Development of a model performance-based sign sheeting specification based on the evaluation of nighttime traffic signs using legibility and eye-tracker data : data and analyses.

    Science.gov (United States)

    2010-09-01

    This report presents data and technical analyses for Texas Department of Transportation Project 0-5235. This : project focused on the evaluation of traffic sign sheeting performance in terms of meeting the nighttime : driver needs. The goal was to de...

  11. Development of a model performance-based sign sheeting specification based on the evaluation of nighttime traffic signs using legibility and eye-tracker data.

    Science.gov (United States)

    2010-09-01

    This project focused on the evaluation of traffic sign sheeting performance in terms of meeting the nighttime : driver needs. The goal was to develop a nighttime driver needs specification for traffic signs. The : researchers used nighttime sign legi...

  12. Evaluation of Novel Polyunsaturated Fatty Acid Derived Lipid Mediators of Inflammation to Ameliorate the Deleterious Effects of Blast Overpressure on Eye and Brain Visual Processing Centers in Rats

    Science.gov (United States)

    2014-10-01

    acid ( DHA ; 22:6ω-3) Eicosapentaenoic acid (EPA; 20:5ω-3) Lipoxin A4 Resolvin E1 Protectin DX Resolvin D1 LOX LOX LOX Structures and Endogenous Source...1 AD_________________ Award Number: W81XWH-12-2-0082 TITLE: Evaluation of Novel Polyunsaturated Fatty Acid Derived Lipid...Evaluation of Novel Polyunsaturated Fatty Acid Derived Lipid Mediators 5a. CONTRACT NUMBER of Inflammation to Ameliorate the Deleterious Effects of

  13. Eye movement perimetry in glaucoma.

    Science.gov (United States)

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  14. System and Method for Eye Tracking

    DEFF Research Database (Denmark)

    2017-01-01

    A method and system for monitoring the motion of one or both eyes, includes capturing a sequence of overlapping images of a subject's face including an eye and the corresponding non-eye region; identifying a plurality of keypoints in each image; mapping corresponding keypoints in two or more images...... of the sequence; assigning the keypoints to the eye and to the corresponding non-eye region; calculating individual velocities of the corresponding keypoints in the eye and the corresponding non-eye region to obtain a distribution of velocities; extracting at least one velocity measured for the eye and at least...... one velocity measured for the corresponding non-eye region; calculating the eye-in-head velocity for the eye based upon the measured velocity for the eye and the measured velocity for the corresponding non-eye region; and calculating the eye-in-head position based upon the eye- in-head velocity....

  15. Cyclosporine Amicellar delivery system for dry eyes.

    Science.gov (United States)

    Kang, Han; Cha, Kwang-Ho; Cho, Wonkyung; Park, Junsung; Park, Hee Jun; Sun, Bo Kyung; Hyun, Sang-Min; Hwang, Sung-Joo

    2016-01-01

    The objectives of this study were to develop stable cyclosporine A (CsA) ophthalmic micelle solutions for dry-eye syndrome and evaluate their physicochemical properties and therapeutic efficacy. CsA-micelle solutions (MS-CsA) were created by a simple method with Cremophor EL, ethanol, and phosphate buffer. We investigated the particle size, pH, and osmolarity. In addition, long-term physical and chemical stability for MS-CsA was observed. To confirm the therapeutic efficacy, tear production in dry eye-induced rabbits was evaluated using the Schirmer tear test (STT). When compared to a commercial product, Restasis, MS-CsA demonstrated improvement in goblet-cell density and conjunctival epithelial morphology, as demonstrated in histological hematoxylin and eosin staining. MS-CsA had a smaller particle size (average diameter 14-18 nm) and a narrow size distribution. Physicochemical parameters, such as particle size, pH, osmolarity, and remaining CsA concentration were all within the expected range of 60 days. STT scores significantly improved in MS-CsA treated groups (Pdry eye-induced rabbits thinned with loss of goblet cells. However, after 5 days of treatment with drug formulations, rabbit conjunctivas recovered epithelia and showed a relative increase in the number of goblet cells. The results of this study indicate the potential use of a novel MS for the ophthalmic delivery of CsA in treating dry eyes.

  16. Eye aberration analysis with Zernike polynomials

    Science.gov (United States)

    Molebny, Vasyl V.; Chyzh, Igor H.; Sokurenko, Vyacheslav M.; Pallikaris, Ioannis G.; Naoumidis, Leonidas P.

    1998-06-01

    New horizons for accurate photorefractive sight correction, afforded by novel flying spot technologies, require adequate measurements of photorefractive properties of an eye. Proposed techniques of eye refraction mapping present results of measurements for finite number of points of eye aperture, requiring to approximate these data by 3D surface. A technique of wave front approximation with Zernike polynomials is described, using optimization of the number of polynomial coefficients. Criterion of optimization is the nearest proximity of the resulted continuous surface to the values calculated for given discrete points. Methodology includes statistical evaluation of minimal root mean square deviation (RMSD) of transverse aberrations, in particular, varying consecutively the values of maximal coefficient indices of Zernike polynomials, recalculating the coefficients, and computing the value of RMSD. Optimization is finished at minimal value of RMSD. Formulas are given for computing ametropia, size of the spot of light on retina, caused by spherical aberration, coma, and astigmatism. Results are illustrated by experimental data, that could be of interest for other applications, where detailed evaluation of eye parameters is needed.

  17. Assessing the Usability of Gaze-Adapted Interface against Conventional Eye-based Input Emulation

    OpenAIRE

    Kumar, Chandan; Menges, Raphael; Staab, Steffen

    2017-01-01

    In recent years, eye tracking systems have greatly improved, beginning to play a promising role as an input medium. Eye trackers can be used for application control either by simply emulating the mouse and keyboard devices in the traditional graphical user interface, or by customized interfaces for eye gaze events. In this work, we evaluate these two approaches to assess their impact in usability. We present a gaze-adapted Twitter application interface with direct interaction of eye gaze inpu...

  18. In vitro eye corrosion study of agrochemicals on isolated chicken eye.

    Science.gov (United States)

    Buda, I; Budai, P; Szabó, R; Lehel, J

    2013-01-01

    Agrochemicals must undergo numberless toxicological tests before marketing. The eye irritation test is part of this test packet. Nowadays, OECD 405 can be used to classify the irritation potential of substances, the base of the OECD 405 guideline is the Draize test, which is one of the most criticized in vivo methods because of the injuries of the test animals and subjective nature of the test in recording the results. Therefore, several in vitro tests have been developed to replace totally or partly the in vivo eye irritation testing. The isolated chicken eye test method (OECD 438), which was used, is one of these alternative methods. Five different agrochemicals were examined in the following way: All test compounds were applied in a single dose onto the cornea of isolated chicken eyes in order to potentially classify the test compounds as ocular corrosive and/or severe irritant. The damages caused by the test substances were assessed by the determination of corneal swelling, opacity, fluorescein retention and morphological effects. These parameters were evaluated pre-treatment and starting at approximately 30, 75, 120, 180, and 240 minutes after the post-treatment rinse. The endpoints evaluated were corneal opacity, swelling, fluorescein retention and morphological effects. All of the endpoints, with the exception of fluorescein retention (which was determined only at pre-treatment and 30 minutes after test substance exposure) were determined at each of the above time points. Positive and negative controls were used and they showed the expected results in each study. In these in vitro eye corrosives and severe irritants studies, using the Isolated Chicken Eye model with five different products, no ocular corrosion or severe irritation potential were observed. These results correspond to the available information about the tested agrochemicals, so these studies with isolated chicken eye are considered to be successful.

  19. Recent advances in laser in situ keratomileusis-associated dry eye.

    Science.gov (United States)

    Xie, Wenjia

    2016-03-01

    Dry eye is the most common complication after laser in situ keratomileusis (LASIK). The major cause of LASIK-associated dry eye is corneal nerve damage. Early identification and treatment of post-operative dry eye are essential to prevent further ocular surface damage. This article reviews the recent studies of LASIK-associated dry eye, including clinical features, aetiology, risk factors, evaluations and treatment. The applications of novel technologies in LASIK-associated dry eye evaluation like anterior segment spectral-domain optical coherence tomography (SD-OCT) and corneal confocal microscopy are also introduced in this review. © 2016 Optometry Australia.

  20. Survey of Ophthalmologists Regarding Practice Patterns for Dry Eye and Sjogren Syndrome.

    Science.gov (United States)

    Bunya, Vatinee Y; Fernandez, Karen B; Ying, Gui-Shuang; Massaro-Giordano, Mina; Macchi, Ilaria; Sulewski, Michael E; Hammersmith, Kristin M; Nagra, Parveen K; Rapuano, Christopher J; Orlin, Stephen E

    2018-01-15

    To survey ophthalmologists about current practice patterns regarding the evaluation of dry eye patients and referrals for a Sjogren syndrome (SS) workup. An online survey was sent to ophthalmologists affiliated with the Scheie Eye Institute or Wills Eye Hospital using REDCap in August 2015. Descriptive statistics were used to summarize the data. Four hundred seventy-four survey invitations were sent out and 101 (21%) ophthalmologists completed the survey. The common traditional dry eye test performed was corneal fluorescein staining (62%) and the most common newer dry eye test performed was tear osmolarity (18%). Half of respondents (51%) refer fewer than 5% of their dry eye patients for SS workups, with 18% reporting that they never refer any patients. The most common reasons for referrals included positive review of systems (60%), severe dry eye symptoms (51%) or ocular signs (47%), or dry eye that is refractory to treatment (42%). The majority (83%) felt that there is a need for an evidence-based standardized screening tool for dry eye patients to decide who should be referred for evaluation for SS. Ophthalmologists continue to prefer the use of traditional dry eye tests in practice, with the most common test being corneal fluorescein staining. There is an underreferral of dry eye patients for SS workups, which is contributing to the continued underdiagnosis of the disease. Most respondents felt that there was a need for an evidence-based standardized screening tool to decide which dry eye patients should be referred for SS evaluations.

  1. Clinical effect of 1g/L anthocyanin eye-patch for mild and moderate dry eye

    Directory of Open Access Journals (Sweden)

    Ke-Hua Wang

    2018-05-01

    Full Text Available AIM:To evaluate the clinic efficacy of 1g/L anthocyanin eye-patch for mild and moderate dry eye. METHODS: In this prospective and multicenter study, a total of 320 cases(640 eyeswith mild and moderate dry eye were enrolled from 8 Aier Eye Hospitals in Changsha, Chongqing, Wuhan and so on from October 2016 to April 2017. The patients were assigned to eye patch group(160 casesand artificial tears group(160 casesbased on random number table. The patients in eye-patch group used 1g/L of anthocyanin eye-patch for more than 6h during night sleep, while the patients in artificial tears group used polyvinyl alcohol eye drops for 4 times per day. The evaluation of symptoms and signs were conducted on 1d before the treatment and 14d after the treatment. The evaluation of symptoms adopted the Ocular Surface Disease Index(OSDI, while the observation of signs included tear secretion test(Schirmer Ⅰ test, SⅠt, first noninvasive tear breakup time(NITBUTfas well as average noninvasive tear breakup time(NITBUTavmeasured by Oculus ocular surface analyser. RESULTS: OSDI score, NITBUTf and NITBUTav in the two groups after treatment were significantly improved compared with that before treatment, and the difference had a statistical significance(PP>0.05. There was no significant difference in OSDI score, NITBUTf, NITBUTav and SⅠt between the two groups after treatment(P>0.05.CONCLUSION: The 1g/L anthocyanin eye-patch has similar efficacy with artificial tears for mild and moderate dry eye, which can effectively improve the symptoms and tear film stability.

  2. Real Time Eye Detector with Cascaded Convolutional Neural Networks

    Directory of Open Access Journals (Sweden)

    Bin Li

    2018-01-01

    Full Text Available An accurate and efficient eye detector is essential for many computer vision applications. In this paper, we present an efficient method to evaluate the eye location from facial images. First, a group of candidate regions with regional extreme points is quickly proposed; then, a set of convolution neural networks (CNNs is adopted to determine the most likely eye region and classify the region as left or right eye; finally, the center of the eye is located with other CNNs. In the experiments using GI4E, BioID, and our datasets, our method attained a detection accuracy which is comparable to existing state-of-the-art methods; meanwhile, our method was faster and adaptable to variations of the images, including external light changes, facial occlusion, and changes in image modality.

  3. With eyes wide open

    DEFF Research Database (Denmark)

    Frølunde, Lisbeth; Pedersen, Chistina Hee

    2013-01-01

    and that vulnerability and discomfort are often overlooked as transformative forces. The analysis draws on data from a classroom context in which university students tested methods for facilitating creative thinking in a course on data production and creativity. The data stem from a session on the method “Lego Serious...... in constructions of group identity when an external facilitator disrupts a context. We argue that the facilitation of creative methods calls for keeping our eyes wide open for tensions, for they are the mulch that improves the soil....

  4. Eye trauma in boxing.

    Science.gov (United States)

    Corrales, Gustavo; Curreri, Anthony

    2009-10-01

    In boxing, along with a few other sports, trauma is inherent to the nature of the sport; therefore it is considered a high-risk sport for ocular injuries. The long-term morbidity of ocular injuries suffered by boxers is difficult to estimate due to the lack of structured long-term follow-up of these athletes. Complications of blunt ocular trauma may develop years after the athlete has retired from the ring and is no longer considered to be at risk for boxing-related injuries. This article describes the wide range of eye injuries a boxer can sustain, and their immediate and long-term clinical management.

  5. Effectiveness of eye armor during blast loading.

    Science.gov (United States)

    Bailoor, Shantanu; Bhardwaj, Rajneesh; Nguyen, Thao D

    2015-11-01

    Ocular trauma is one of the most common types of combat injuries resulting from the interaction of military personnel with improvised explosive devices. Ocular blast injury mechanisms are complex, and trauma may occur through various injury mechanisms. However, primary blast injuries (PBI) are an important cause of ocular trauma that may go unnoticed and result in significant damage to internal ocular tissues and visual impairment. Further, the effectiveness of commonly employed eye armor, designed for ballistic and laser protection, in lessening the severity of adverse blast overpressures (BOP) is unknown. In this paper, we employed a three-dimensional (3D) fluid-structure interaction computational model for assessing effectiveness of the eye armor during blast loading on human eyes and validated results against free field blast measurements by Bentz and Grimm (2013). Numerical simulations show that the blast waves focused on the ocular region because of reflections from surrounding facial features and resulted in considerable increase in BOP. We evaluated the effectiveness of spectacles and goggles in mitigating the pressure loading using the computational model. Our results corroborate experimental measurements showing that the goggles were more effective than spectacles in mitigating BOP loading on the eye. Numerical results confirmed that the goggles significantly reduced blast wave penetration in the space between the armor and the eyes and provided larger clearance space for blast wave expansion after penetration than the spectacles. The spectacles as well as the goggles were more effective in reducing reflected BOP at higher charge mass because of the larger decrease in dynamic pressures after the impact. The goggles provided greater benefit of reducing the peak pressure than the spectacles for lower charge mass. However, the goggles resulted in moderate, sustained elevated pressure loading on the eye, that became 50-100% larger than the pressure loading

  6. On Biometrics With Eye Movements.

    Science.gov (United States)

    Zhang, Youming; Juhola, Martti

    2017-09-01

    Eye movements are a relatively novel data source for biometric identification. When video cameras applied to eye tracking become smaller and more efficient, this data source could offer interesting opportunities for the development of eye movement biometrics. In this paper, we study primarily biometric identification as seen as a classification task of multiple classes, and secondarily biometric verification considered as binary classification. Our research is based on the saccadic eye movement signal measurements from 109 young subjects. In order to test the data measured, we use a procedure of biometric identification according to the one-versus-one (subject) principle. In a development from our previous research, which also involved biometric verification based on saccadic eye movements, we now apply another eye movement tracker device with a higher sampling frequency of 250 Hz. The results obtained are good, with correct identification rates at 80-90% at their best.

  7. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...... mobile phone screens. The user study shows that the method detects a set of defined gestures reliably.......A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...

  8. Dexamethasone nanowafer as an effective therapy for dry eye disease.

    Science.gov (United States)

    Coursey, Terry G; Henriksson, Johanna Tukler; Marcano, Daniela C; Shin, Crystal S; Isenhart, Lucas C; Ahmed, Faheem; De Paiva, Cintia S; Pflugfelder, Stephen C; Acharya, Ghanashyam

    2015-09-10

    Dry eye disease is a major public health problem that affects millions of people worldwide. It is presently treated with artificial tear and anti-inflammatory eye drops that are generally administered several times a day and may have limited therapeutic efficacy. To improve convenience and efficacy, a dexamethasone (Dex) loaded nanowafer (Dex-NW) has been developed that can release the drug on the ocular surface for a longer duration of time than drops, during which it slowly dissolves. The Dex-NW was fabricated using carboxymethyl cellulose polymer and contains arrays of 500 nm square drug reservoirs filled with Dex. The in vivo efficacy of the Dex-NW was evaluated using an experimental mouse dry eye model. These studies demonstrated that once a day Dex-NW treatment on alternate days during a five-day treatment period was able to restore a healthy ocular surface and corneal barrier function with comparable efficacy to twice a day topically applied dexamethasone eye drop treatment. The Dex-NW was also very effective in down regulating expression of inflammatory cytokines (TNF-α, and IFN-γ), chemokines (CXCL-10 and CCL-5), and MMP-3, that are stimulated by dry eye. Despite less frequent dosing, the Dex-NW has comparable therapeutic efficacy to topically applied Dex eye drops in experimental mouse dry eye model, and these results provide a strong rationale for translation to human clinical trials for dry eye. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Complications related to a cosmetic eye-whitening procedure.

    Science.gov (United States)

    Vo, Rosalind C; Stafeeva, Ksenia; Aldave, Anthony J; Stulting, R Doyle; Moore, Quianta; Pflugfelder, Stephen C; Chungfat, Neil C; Holsclaw, Douglas S; Margolis, Todd P; Deng, Sophie X

    2014-11-01

    To report sight-threatening complications following extensive bulbar conjunctival resection and postoperative mitomycin C therapy for cosmetic eye-whitening in the United States. Retrospective noncomparative case series. Multicenter report of 9 patients referred for evaluation and management of complications following bilateral cosmetic eye whitening. Seventeen eyes of 9 patients underwent cosmetic eye-whitening performed between 2 and 48 months prior to referral to one of the centers. Sixteen of the 17 eyes had persistent conjunctival epithelial defects, with 10 eyes requiring amniotic membrane grafting to facilitate re-epithelialization. Four eyes of 2 patients developed limbal stem cell compromise confirmed with in vivo confocal laser scanning microscopy. One patient developed infectious scleritis and diplopia resulting from Tenon capsule scarring. Another patient developed scleral necrosis, secondary infectious scleritis, and infectious endophthalmitis. This patient subsequently developed noninfectious scleritis that required 3-drug-regimen immunosuppression. Severe adverse effects can occur after extensive cosmetic conjunctival resection followed by topical mitomycin C application. Patients and physicians should be aware of the potential sight-threatening complications associated with this eye-whitening procedure. Published by Elsevier Inc.

  10. Human secretory phospholipase A(2), group IB in normal eyes and in eye diseases

    DEFF Research Database (Denmark)

    Kolko, Miriam; Prause, Jan U; Bazan, Nicolas G

    2007-01-01

    , retinitis pigmentosa and glaucoma were evaluated. RESULTS: Expression of hGIB was found in various cells of the eye. The most abundant expression was found in retinal pigment epithelium (RPE) cells, the inner photoreceptor segments, ganglion cells and the corneal endothelium. We explored diseases involving...

  11. Ultraviolet radiation: the eye

    International Nuclear Information System (INIS)

    Cesarini, J.P.; Sliney, D.H.

    1996-01-01

    Under most conditions, the eye is well adapted to protect itself against ultraviolet radiation encountered in the outdoor environment as a result of the exposure geometry of the sun. Only when snow is on the ground does one experience acute effects of UV sunlight exposure (i.e. snow blindness, or photokeratitis). With regard to artificial sources, there are many occasions where one views bright light sources such as tungsten-halogen lamps, arc lamps and welding arcs. Such viewing is normally only momentary because of the aversion response to bright light and due to discomfort glare. However, such an aversion does not take place for germicidal lamps and other UV lamps which do not contain a strong visible component in their spectrum. The adverse effects from viewing such sources has been studied for decades and during the last two decades guidelines for limiting exposure to protect the eye have been developed. The guidelines were fostered to a large extent by the growing use of lasers and the quickly recognized hazard posed by viewing laser sources. (author)

  12. Chapter 2. Eyes

    International Nuclear Information System (INIS)

    Blanquet, P.

    1975-01-01

    Ocular scintigraphy can now be carried out with several tracers: 131 I diiodofluorescein and sup(99m)Tc, hypervascularisation indicators; 131 I iodinated chloroquine, melanoma selective. The detector used is an Anger scintillation camera coupled to a multiparameter analysis chain or a computer. The ''pin-hole'' type collimator, which has a stenopaeic opening in front of each eye, is adaptable to any inter-pupil distance. The very simple scintigraphic procedure is described. The results, taken from two statistical studies on 198 and 80 patients respectively, concern the main types of eye disease encountered: malignant melanic tumours, other tumours, metastases, choroiditis, idiopathic detachments of the retina etc... The interpretation of the scintigrams and the problems involved are considered. Finally the main indications of the method are defined with emphasis on the possibilities of double scintigraphy, diiodofluorescein only showing up the hypervascularisation often associated with the tumour whereas iodinated chloroquine, when the result is positive, points to the presence of a malignant melanoma [fr

  13. Efficiency and safety of subconjunctival injection of anti-VEGF agent - bevacizumab - in treating dry eye.

    Science.gov (United States)

    Jiang, Xiaodan; Lv, Huibin; Qiu, Weiqiang; Liu, Ziyuan; Li, Xuemin; Wang, Wei

    2015-01-01

    Dry eye is a chronic inflammatory ocular surface disease with high prevalence. The current therapies for dry eye remain to be unspecific and notcomprehensive. This study aims to explore safety and efficacy of a novel treatment - subconjunctival injection of bevacizumab - in dry eye patients. Sixty-four eyes of 32 dry eye patients received subconjunctival injection of 100 μL 25 mg/mL bevacizumab. Dry eye symptoms, signs (corrected visual acuity, intraocular pressure, conjunctival vascularity, corneal staining, tear break-up time, Marx line score, and blood pressure), and conjunctival impression cytology were evaluated 3 days before and 1 week, 1 month, and 3 months after injection. Significant improvements were observed in dry eye symptoms, tear break-up time, and conjunctival vascularization area at all the visits after injection compared to the baseline (Pdry eye disease.

  14. Post-LASIK dry eye

    Science.gov (United States)

    Shtein, Roni M

    2011-01-01

    Laser-assisted in situ keratomileusis (LASIK) is a frequently performed corneal refractive surgery with excellent refractive outcomes. The most common complication of LASIK is dry eyes, with virtually all patients developing some degree of dryness in the immediate postoperative period. Identifying preoperative dry eyes, and conscientious attention and treatment in the perioperative time period, can lead to enhanced patient satisfaction and more accurate visual outcomes. Improved understanding of the development of dry eyes after LASIK will advance our understanding of the complex pathophysiology of dry eye disease. PMID:22174730

  15. Juvenile eye growth, when completed?

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Christensen, Anders S; Fledelius, Christian

    2014-01-01

    PURPOSE: To test Sorsby's classical statement of axial eye growth as completed at the age of 13 years, with a view also to differentiating between basic eye growth and juvenile elongation associated with eventual refractive change towards myopia. METHODS: (i) A total of 160 healthy eyes close...... about age 13 as general limit found support from the cross-sectional data, which suggested stable emmetropic eye size from about 11-12 years, with an average apparently outgrown male emmetropic value of 23.5 mm versus females' 22.9 mm. The longitudinal data, however, showed emmetropic growth also beyond...

  16. Public Awareness regarding Common Eye Diseases among Saudi Adults in Riyadh City: A Quantitative Study

    Directory of Open Access Journals (Sweden)

    Waleed A. Al Rashed

    2017-01-01

    Full Text Available Aim. The current study aimed to evaluate the knowledge of eye disease and awareness of eye care among the Saudi adults and to explore existing eye-related misconceptions in the community. Methods. A cross-sectional study was conducted in Riyadh city during May and June 2016. A self-administered anonymous online questionnaire was used to explore the most common misconceptions related to eye diseases and eye care. Results. Out of 1000 individuals, only 711 (71.1% participant responses were received. The participants’ acceptable knowledge (score ≥50% was high about the eye problem in diabetes (88.6%, ocular trauma (81.2%, and other general eye diseases (91.3%, whereas low about refractive errors (63%, pediatric eye problems (51.5%, and glaucoma (14.8%. The variation in knowledge about specific ocular morbidities was significant (p<0.001. The majority of participants reported sources of information about the common eye diseases and eye care encountered from the community, internet-based resources, and social media. Conclusions. The majority of the participants had awareness about the common eye diseases, whereas low percentage of participant’s awareness about specific condition of eye diseases. Public eye health awareness should be more focused on social media and the internet to be able to cover the younger individuals of the community.

  17. The application of autologous serum eye drops in severe dry eye patients; subjective and objective parameters before and after treatment.

    Science.gov (United States)

    Jirsova, Katerina; Brejchova, Kristyna; Krabcova, Ivana; Filipec, Martin; Al Fakih, Aref; Palos, Michalis; Vesela, Viera

    2014-01-01

    To assess the impact of autologous serum (AS) eye drops on the ocular surface of patients with bilateral severe dry eye and to draw a comparison between the clinical and laboratory examinations and the degree of subjective symptoms before and after serum treatment. A three-month prospective study was conducted on 17 patients with severe dry eye. AS eye drops were applied a maximum of 12 times a day together with regular therapy. Dry eye status was evaluated by clinical examination (visual acuity, Schirmer test, tear film breakup time, vital staining, tear film debris and meniscus), conjunctival impression cytology (epithelial and goblet cell density, snake-like chromatin, HLA-DR-positive and apoptotic cells) and subjectively by the patients. The application of AS eye drops led to a significant improvement in the Schirmer test (p treatment. A significant decrease (p eyes. We found that three-month AS treatment led especially to the improvement of ocular surface dryness and damage of the epithelium. The improvement of dry eye after AS treatment correlated well with the clinical, laboratory and subjective findings. From the patients' subjective point of view, the positive effect of AS decreased with time, but still persisted up to three months after the end of therapy.

  18. Chronic dry eye in PRK and LASIK: manifestations, incidence and predictive factors

    Science.gov (United States)

    Bower, Kraig S.; Sia, Rose K.; Ryan, Denise S.; Mines, Michael J.; Dartt, Darlene A.

    2017-01-01

    Purpose To evaluate dry eye manifestations following photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) and determine the incidence and predictive factors of chronic dry eye using a set of dry eye criteria. Setting Walter Reed Army Medical Center, Washington, DC, USA Methods This is a prospective non-randomized clinical study of 143 active duty U.S. Army personnel aged 29.9±5.2 years with myopia or myopic astigmatism (manifest spherical equivalent −3.83±1.96 diopters) undergoing either PRK or LASIK. Dry eye evaluation was performed pre- and postoperatively. Main outcome measures included dry eye manifestations, incidence, and predictive factors of chronic dry eye. Results Schirmer scores, corneal sensitivity, ocular surface staining, surface regularity index (SRI), and responses to dry eye questionnaire significantly changed over time after PRK. After LASIK, significant changes were observed in tear breakup time, corneal sensitivity, ocular surface staining, and responses to questionnaire. At twelve months postoperatively, 5.0% of PRK and 0.8% of LASIK participants developed chronic dry eye. Regression analysis showed preoperatively lower Schirmer score will significantly influence development of chronic dry eye after PRK whereas preoperatively lower Schirmer score or higher ocular surface staining score will significantly influence the occurrence of chronic dry eye after LASIK. Conclusions Chronic dry eye is uncommon after PRK and LASIK. Ocular surface and tear film characteristics during preoperative examination may help predict chronic dry eye development in PRK and LASIK. PMID:26796443

  19. Association of IL-21 cytokine with severity of primary Sjögren syndrome dry eye.

    Science.gov (United States)

    Lim, Sung A; Nam, Doo Hyun; Lee, Jee Hye; Kwok, Seung-Ki; Park, Sung-Hwan; Chung, So-Hyang

    2015-03-01

    IL-21 plays an important role in primary Sjögren syndrome (SS) pathogenesis. The purpose of this study was to evaluate IL-21 expression in tears and the conjunctiva and to analyze the impact of IL-21 on primary SS dry eyes. Eighty subjects were enrolled in this study: 30 patients with primary SS dry eye (30 eyes); 30 patients with non-SS dry eye (30 eyes), and 20 normal controls. Tear IL-21 levels were measured by flow cytometry, and IL-21 gene expression in the conjunctiva from impression cytology was evaluated by quantitative polymerase chain reaction. Ocular Surface Disease Index, tear film breakup time, Schirmer I test, and ocular surface staining scores were obtained for all patients. Primary SS dry eyes had significantly higher tear IL-21 levels than non-SS dry eyes and normal controls (P dry eyes than in non-SS dry eyes and normal controls (P dry eyes and controls. The tear IL-21 level was significantly correlated with ocular surface stain scores (r = 0.54, P dry eyes. Our findings suggest that severity of primary SS dry eye is associated with IL-21.

  20. Prevalence of Dry Eye in Uyghur and Han Ethnic Groups in Western China.

    Science.gov (United States)

    Gong, Ying-Ying; Zhang, Fan; Zhou, Jin; Li, Jing; Zhang, Guang-Hui; Wang, Jun-Liang; Gu, Zhen-Sheng

    2017-06-01

    To describe and compare the prevalence and characteristics of dry eye among Han and Uyghur persons living in Kashi, the most inland city of China. A total of 1015 residents of Kashi participated in this 2013 cross-sectional study. To evaluate clinical characteristics, each subject completed (1) a dry-eye questionnaire detailing symptoms of dry eye, (2) Schirmer's I-test (SIT), (3) tear-film break-up time (BUT) test, and fluorescein staining of the cornea. Dry eye was defined as the existence of dry eye symptoms and at least two positive clinical signs. Data were analyzed using SPSS software. The prevalence and risk factors of dry eye were evaluated using a multivariate model. Overall, 282 (27.8%) of the 1015 participants were diagnosed with dry eye (95% confidence interval (CI): range, 25.5-30.1). The prevalence of dry eye among Han persons (37.9 %) (95% CI: range, 35.8-40.0) was higher than that among Uyghurs (21.8%) (95% CI: 19.6-24.0) (p dry eye was 25.6% (95% CI: range, 23.3-27.8) among men and 28.7% (95% CI: 26.5-30.9) among women (p > 0.05). Risk factors for dry eye included ethnicity, age, occupation, arthritis, and dry mouth. Our study revealed a higher prevalence of dry eye among Han than Uyghur persons in Kashi. Dry eye was significantly associated with environment and ethnicity.

  1. Efficacy of combined pranoprofen eye drops and artificial tears on the treatment of mild to moderate dry eye syndrome after trabbeculectomy

    Directory of Open Access Journals (Sweden)

    Guang-Ming Zhao

    2015-02-01

    Full Text Available AIM:To evaluate the efficacy of combined pranoprofen eye drops and artificial tears on the treatment of mild to moderate dry eye syndrome after trabbeculectomy. METHODS: This prospective case control study included 63 cases(63 eyesof patients with mild to moderate dry eye syndrome after trabbeculectomy in our hospital from November 2013 to June 2013. All subjects were randomly divided into two groups. Observation group was treated with combined pranoprofen eye drops and artificial tears and control group received simple artificial tears marking the eyes at 1, 2, 4wk. The patient's symptoms, signs, BUT, SⅠt, and FL were observed before treatment and 1, 2, 4wk after treatment. RESULTS:After 2wk, the symptoms of observation group were improved, there was statistically significant difference(PPPPCONCLUSION: Artificial tears joint pranoprofen eye drops has good curative effect in the treatment of mild to moderate dry eye syndrome after trabbeculectomy.

  2. Effectiveness of Autologous Serum Eye Drops Combined With Punctal Plugs for the Treatment of Sjögren Syndrome-Related Dry Eye.

    Science.gov (United States)

    Liu, Ying; Hirayama, Masatoshi; Cui, Xin; Connell, Samuel; Kawakita, Tetsuya; Tsubota, Kazuo

    2015-10-01

    To evaluate the efficacy and safety of autologous serum (AS) eye drops combined with punctal plugs (PPs) in patients with Sjögren syndrome (SS)-related dry eye. A retrospective clinical study was performed in patients with dry eye caused by SS. We evaluated the Schirmer test value, tear breakup time (tBUT), and fluorescein and Rose Bengal (RB) staining scores at baseline, 3 months, 6 months, 1 year, and >1 year after treatment. The dry eye indexes were also evaluated in 2 subgroups, which determined by the using of PPs, including the AS + PP group and AS only group. A total of 56 eyes of 28 patients were investigated with a mean follow-up of 42.3 ± 26.1 months. After the application of AS eye drops, the Schirmer test showed no significant changes. The tBUT (2.7 ± 1.9 seconds) was significantly improved at each time point (3.9 ± 3.1, 4.5 ± 3.1, 3.7 ± 2.5, and 5.1 ± 4.0; P eye drops was found to be an effective and apparently safe treatment for SS dry eye. Furthermore, PPs in combination with AS eye drops were considered to have an additive effect on SS dry eye.

  3. Live Speech Driven Head-and-Eye Motion Generators.

    Science.gov (United States)

    Le, Binh H; Ma, Xiaohan; Deng, Zhigang

    2012-11-01

    This paper describes a fully automated framework to generate realistic head motion, eye gaze, and eyelid motion simultaneously based on live (or recorded) speech input. Its central idea is to learn separate yet interrelated statistical models for each component (head motion, gaze, or eyelid motion) from a prerecorded facial motion data set: 1) Gaussian Mixture Models and gradient descent optimization algorithm are employed to generate head motion from speech features; 2) Nonlinear Dynamic Canonical Correlation Analysis model is used to synthesize eye gaze from head motion and speech features, and 3) nonnegative linear regression is used to model voluntary eye lid motion and log-normal distribution is used to describe involuntary eye blinks. Several user studies are conducted to evaluate the effectiveness of the proposed speech-driven head and eye motion generator using the well-established paired comparison methodology. Our evaluation results clearly show that this approach can significantly outperform the state-of-the-art head and eye motion generation algorithms. In addition, a novel mocap+video hybrid data acquisition technique is introduced to record high-fidelity head movement, eye gaze, and eyelid motion simultaneously.

  4. For your eyes only: Effect of confederate's eye level on reach-to-grasp action

    Directory of Open Access Journals (Sweden)

    Francois eQuesque

    2014-12-01

    Full Text Available Previous studies have shown that the spatio-temporal parameters of reach-to-grasp movement are influenced by the social context in which the motor action is performed. In particular, when interacting with a confederate, movements are slower, with longer initiation times and more ample trajectories, which has been interpreted as implicit communicative information emerging through voluntary movement to catch the partner’s attention and optimize cooperation (Quesque et al., 2013. Because gaze is a crucial component of social interactions, the present study evaluated the role of a confederate's eye level on the social modulation of trajectory curvature. An actor and a partner facing each other took part in a cooperative task consisting, for one of them, of grasping and moving a wooden dowel under time constraints. Before this Main action, the actor performed a Preparatory action, which consisted of placing the wooden dowel on a central marking. The partner's eye level was unnoticeably varied using an adjustable seat that matched or was higher than the actor’s seat. Our data confirmed the previous effects of social intention on motor responses. Furthermore, we observed an effect of the partner's eye level on the Preparatory action, leading the actors to exaggerate unconsciously the trajectory curvature in relation to their partner's eye level. No interaction was found between the actor's social intention and their partner's eye level. These results suggest that other bodies are implicitly taken into account when a reach-to-grasp movement is produced in a social context.

  5. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

    Directory of Open Access Journals (Sweden)

    Xinjie Mao

    Full Text Available To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor.Twenty-eight adult subjects (32 pseudophakic eyes having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR and intraclass correlation coefficient (ICC were calculated.Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951.The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.

  6. Biophysical evaluation of the radioprotective role of thiola and olive oil during the treatment of some eye lesions with beta particles

    International Nuclear Information System (INIS)

    Mahmoud, S.S.; Gamal, M.M.

    2003-01-01

    This study was conducted to evaluate the radioactive efficacy of topical application of the radioprotector thiola alone or when combined with olive oil on the biophysical characteristics of lens lipids. Two groups of New Zealand white rabbits were used in this study. The first group (thiola group) was topically applied with thiola thirty minutes and one minute before the treatment with two doses of beta particles (24Gy and 100 Gy). The second group (olive oil and thipla group) was also received thiola as in the first group then olive oil was topically applied after the irradiationand countinue daily till decapitation. The lens lipids were studied using UV-spectroscopy, fourier transform infrared spectroscopy and phase transition measurement. In additio, cholesterol and phospholipids concentrations were measured. The resulted typical absorption spectra of the lens lipids indicated that the native lipid peak was shifted towards higher wave length for both doses (24 Gy and 100 Gy) in both olive oil group and the thiola group. The results also indicated that there were fluctuated changes in lens stability and fluidity concomintant with conformational and compositional changes in both groups. It may be concluded from the present study that application of thiola alone or combined with olive oil seems to be promising tool in preventing the peroxidation of lens lipids induced by beta radiation tretments

  7. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  8. Changes of Corneal Wavefront Aberrations in Dry Eye Patients after Treatment with Artificial Lubricant Drops

    Directory of Open Access Journals (Sweden)

    Ning Lu

    2016-01-01

    Full Text Available Purpose. To evaluate the corneal aberration changes in dry eye patients after treatment with artificial eye drops. Methods. Thirty mild to moderate dry eye patients treated with artificial eye drops and twenty comparable dry eye patients were recruited as controls. Anterior corneal aberrations over 3 mm and 5 mm analytical zones including total, 3rd to 5th high order aberrations (HOAs, spherical aberration (SA, and vertical (V-coma and horizontal coma (H-coma obtained from corneal topography data at baseline and 2 weeks after treatment were evaluated. Results. For 3 mm zone, trefoils, V-coma, H-coma terms, and 3rd and 5th HOAs were significantly decreased (p0.05. Conclusions. Treatment with artificial eye drops can effectively improve the corneal optical quality of dry eye patients by ameliorating the HOAs of anterior corneal surface.

  9. Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.

    Science.gov (United States)

    Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio

    2015-01-01

    In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.

  10. Eye Movements in Gaze Interaction

    DEFF Research Database (Denmark)

    Møllenbach, Emilie; Hansen, John Paulin; Lillholm, Martin

    2013-01-01

    Gaze as a sole input modality must support complex navigation and selection tasks. Gaze interaction combines specific eye movements and graphic display objects (GDOs). This paper suggests a unifying taxonomy of gaze interaction principles. The taxonomy deals with three types of eye movements...

  11. Compensatory eye movements in mice

    NARCIS (Netherlands)

    A.M. van Alphen (Arjan)

    2002-01-01

    textabstractThis thesis will address the generation of compensatory eye movements in naturally mutated or genetically modified mice. The reason for generating compensatory eye movements is solely related to the requirements for good vision. In a subject moving through its environment the projection

  12. Telemedicine and Diabetic Eye Disease

    Centers for Disease Control (CDC) Podcasts

    We know that the leading cause of blindness in working-age adults is eye disease related to poorly managed diabetes. In a prevention research study, telemedicine was shown to increase the number of people getting screened for diabetic eye disease.

  13. Genetic Testing and Eye Disease

    Science.gov (United States)

    ... condition called Cogan’s syndrome. Google AI May Reveal Health Risks Through Your Eyes FEB 20, 2018 By Ari Soglin Researchers at Google say a new application of artificial intelligence shows whether a patient’s eyes point to high ...

  14. Penetrating eye injury in war.

    Science.gov (United States)

    Biehl, J W; Valdez, J; Hemady, R K; Steidl, S M; Bourke, D L

    1999-11-01

    The percentage of penetrating eye injuries in war has increased significantly in this century compared with the total number of combat injuries. With the increasing use of fragmentation weapons and possibly laser weapons on the battle-field in the future, the rate of eye injuries may exceed the 13% of the total military injuries found in Operations Desert Storm/Shield. During the Iran-Iraq War (1980-1988), eye injuries revealed that retained foreign bodies and posterior segment injuries have an improved prognosis in future military ophthalmic surgery as a result of modern diagnostic and treatment modalities. Compared with the increasing penetrating eye injuries on the battlefield, advances in ophthalmic surgery are insignificant. Eye armor, such as visors that flip up and down and protect the eyes from laser injury, needs to be developed. Similar eye protection is being developed in civilian sportswear. Penetrating eye injury in the civilian sector is becoming much closer to the military model and is now comparable for several reasons.

  15. Cellular proliferation and regeneration following tissue damage. Progress report. [Eyes

    Energy Technology Data Exchange (ETDEWEB)

    Harding, C.V.

    1976-10-01

    Results are reported from a study of wound healing in tissues of the eye, particularly lens, cornea, and surrounding tissues. The reactions of these tissues to mechanical injuries, as well as injuries induced by chemotoxic agents were studied. It is postulated that a better understanding of the basic reactions of the eye to injurious agents may be of importance in the evaluation of potential environmental hazards.

  16. Is ultrasonography essential before surgery in eyes with advanced cataracts?

    Directory of Open Access Journals (Sweden)

    Salman Amjad

    2006-01-01

    Full Text Available Background: Ultrasonography is an important tool for evaluating the posterior segment in eyes with opaque media. Aim: To study the incidence of posterior segment pathology in eyes with advanced cataract and to see whether certain features could be used as predictors for an abnormal posterior segment on ultrasound. Setting: Tertiary care hospital in South India. Methods and Materials: In this prospective study conducted over a 6-month period, all eyes with dense cataracts precluding visualization of fundus underwent assessment with ultrasound. Presence of certain patient and ocular "risk" factors believed to be associated with a higher incidence of abnormal posterior segment on ultrasound were looked for and the odds ratio (OR for posterior segment pathology in these eyes was calculated. Results: Of the 418 eyes assessed, 36 eyes (8.6% had evidence of posterior segment pathology on ultrasound. Retinal detachment (17 eyes; 4.1% was the most frequent abnormality detected. Among patient features, diabetes mellitus (OR= 4.9, P=0.003 and age below 50 years (OR= 15.4, P=0.001 were associated with a high incidence of abnormal ultrasound scans. In ocular features, posterior synechiae (OR= 20.2, P=0.000, iris coloboma (OR= 34.6, P=0.000, inaccurate projection of rays (OR= 15.1, P=0.002, elevated intraocular pressure (OR= 15.1, P=0.004, and keratic precipitates (OR= 22.4, P=0.004 were associated with high incidence of posterior segment pathology. Only four eyes (1.5% without these features had abnormal posterior segment on ultrasonography. Conclusions: Certain patient and ocular features are indicative of a high risk for posterior segment pathology and such patients should be evaluated by ultrasonography prior to cataract surgery. In the absence of these risk factors, the likelihood of detecting abnormalities on preoperative ultrasonography in eyes with advanced cataracts is miniscule.

  17. Aqueous proinflammatory cytokines in acute primary angle-closure eyes

    Directory of Open Access Journals (Sweden)

    Yao-Ming Liu

    2017-05-01

    Full Text Available AIM: To evaluate changes of proinflammatory cytokines in aqueous humor of patients with acute primary angle-closure (APAC and age-related cataracts. METHODS: Twenty eyes of 20 APAC patients and 15 eyes of 15 age-related cataract patients were included in this cross-sectional study. Aqueous humor samples were collected prospectively. The levels of 20 proinflammatory cytokines were evaluated in the aqueous humor of the APAC and cataract patients using the multiplex bead immunoassay technique. Clinical data were collected for correlation analysis. RESULTS: Seven of the 20 proinflammatory cytokines included in the magnetic bead panel were detectable in both APAC eyes and cataract eyes: interleukin (IL-10, IL-12, IL-15, IL-21, IL-6, chemokine (C-C motif ligand 20, and tumor necrosis factor alpha (TNF-α. IL-27 was only detectable in APAC eyes. Compared with the cataract eyes, the APAC eyes had significantly elevated concentrations of IL-12 (P=0.036, IL-15 (P=0.001, IL-6 (P=0.012, and IL-27 (only detectable in APAC eyes. Age was positively correlated with IL-12 (P=0.022 and IL-6 (P=0.037, and time elapsed between APAC onset and aqueous humor samples collection was positively correlated with IL-15 (P=0.037, IL-27 (P=0.040, and TNF-α (P=0.042. CONCLUSION: Several proinflammatory cytokines including IL-12,IL-15, IL-6 and IL-27, were elevated in the APAC eyes and may be implicated in its pathologic mechanism.

  18. Manifestation of meibomian gland dysfunction in patients with Sjögren's syndrome, non-Sjögren's dry eye, and non-dry eye controls.

    Science.gov (United States)

    Kang, Yeon Soo; Lee, Hyo Seok; Li, Ying; Choi, Won; Yoon, Kyung Chul

    2018-06-01

    To evaluate the manifestation of meibomian gland dysfunction in patients with Sjögren's syndrome (SS), non-Sjögren's syndrome dry eye (non-SS) patients, and non-dry eye controls. We recruited 31 participants with SS dry eye, 30 participants with non-SS dry eye, and 35 healthy controls without dry eye symptoms. Noninvasive tear breakup time (NITBUT) and meibomian gland dropout score (meiboscore) were measured using the Oculus Keratograph 5 M. Meibomian gland expressibility and secretion quality were evaluated via slit lamp biomicroscopy. The correlation between measurements was analyzed. NITBUT was lower, and the meiboscore, meibomian gland expressibility, and secretion quality scores were significantly higher in the SS and non-SS groups than in the control group (p dry eye controls. SS patients had more severe meibomian gland dysfunction with poorer mean meiboscore and meibomian gland expressibility than non-SS patients.

  19. Sun, UV Radiation and Your Eyes

    Science.gov (United States)

    ... Sunglasses Sun Smart UV Safety Infographic The Sun, UV Radiation and Your Eyes Leer en Español: El ... Aug. 28, 2014 Keep an Eye on Ultraviolet (UV) Safety Eye medical doctors (ophthalmologists) caution us that ...

  20. Prevalence and phenomenology of eye tics in Gilles de la Tourette syndrome.

    Science.gov (United States)

    Martino, Davide; Cavanna, Andrea E; Robertson, Mary M; Orth, Michael

    2012-10-01

    Eye tics seem to be common in Gilles de la Tourette syndrome (GTS). We analyzed the frequency and clinical characteristics of eye tics in 212 GTS patients. Of the 212 patients, 201 (94.8 %) reported eye tics in their life-time; 166 (78.3 %) reported eye movement tics (rolling eyes up/down, eyes looking sideways, staring), and 194 (91.5 %) eyelid/eyebrow movement tics (frowning, raising eyebrows, blinking or winking). Patients with eye movement tics were younger at age of GTS onset (7.1 ± 4 years) than those without (8.9 ± 6.8; p = 0.024). Tic severity positively correlated to lifetime history of eye and/or eyelid/eyebrow movement tics. Our data confirm that eye and eyelid/eyebrow movement tics are very common in GTS, and most patients have several types of eye tics over time. Eye tic phenomenology was similar in patients with or without co-morbidity. Eye tics are therefore likely to be a core feature of GTS and should be routinely evaluated in order to strengthen the clinician's confidence in diagnosing GTS.