WorldWideScience

Sample records for sagittally focusing photons

  1. Conical geometry for sagittal focusing as applied to X rays from synchrotrons

    International Nuclear Information System (INIS)

    Ice, G.E.; Sparks, C.J.

    1993-06-01

    The authors describe a method for simultaneously focusing and monochromatization of X rays from a fan of radiation having up to 15 mrad divergence in one dimension. This geometry is well suited to synchrotron radiation sources at magnifications of one-fifth to two and is efficient for X-ray energies between 3 and 40 keV (0.48 and 6.4 fJ). The method uses crystals bent to part of a cone for sagittal focusing and allows for the collection of a larger divergence with less mixing of the horizontal into the vertical divergence than is possible with X-ray mirrors. They describe the geometry required to achieve the highest efficiency when a conical crystal follows a flat crystal in a nondispersive two-crystal monochromator. At a magnification of one-third, the geometry is identical to a cylindrical focusing design described previously. A simple theoretical calculation is shown to agree well with ray-tracing results. Minimum aberrations are observed at magnifications near one. Applications of the conical focusing geometry to existing and future synchrotron radiation facilities are discussed

  2. Far-Field Focus and Dispersionless Anticrossing Bands in Two-Dimensional Photonic Crystals

    Directory of Open Access Journals (Sweden)

    Xiaoshuang Chen

    2007-01-01

    Full Text Available We review the simulation work for the far-field focus and dispersionless anticrossing bands in two-dimensional (2D photonic crystals. In a two-dimensional photonic-crystal-based concave lens, the far-field focus of a plane wave is given by the distance between the focusing point and the lens. Strong and good-quality far-field focusing of a transmitted wave, explicitly following the well-known wave-beam negative refraction law, can be achieved. The spatial frequency information of the Bloch mode in multiple Brillouin zones (BZs is investigated in order to indicate the wave propagation in two different regions. When considering the photonic transmission in a 2D photonic crystal composed of a negative phase-velocity medium (NPVM, it is shown that the dispersionless anticrossing bands are generated by the couplings among the localized surface polaritons of the NPVM rods. The photonic band structures of the NPVM photonic crystals are characterized by a topographical continuous dispersion relationship accompanied by many anticrossing bands.

  3. Focus issue introduction: nonlinear photonics.

    Science.gov (United States)

    Akhmediev, Nail; Rottwitt, Karsten

    2012-11-19

    It is now 23 years since the first Topical Meeting "Nonlinear Guided Wave Phenomena" (Houston, TX, February 2-4, 1989) has been organised by George Stegeman and Allan Boardman with support of the Optical Society of America. These series of the OSA conferences known as NLGW, continued under the name "Nonlinear Photonics" starting from 2007. The latest one, in Colorado Springs in June 17-21, 2012 has been a great success despite the fierce fires advancing around the city at the time of the conference. This Focus issue is a collection of several papers presented at the conference with extended content submitted to Optics Express. Although this collection is small in comparison to the total number of papers presented at the conference, it gives a flavor of the topics considered at the meeting. It is also worthy to mention here that the next meeting "Nonlinear Photonics" is planned to be held in Barcelona - one of the main European centers on this subject.

  4. Wide-field two-photon microscopy with temporal focusing and HiLo background rejection

    Science.gov (United States)

    Yew, Elijah Y. S.; Choi, Heejin; Kim, Daekeun; So, Peter T. C.

    2011-03-01

    Scanningless depth-resolved microscopy is achieved through spatial-temporal focusing and has been demonstrated previously. The advantage of this method is that a large area may be imaged without scanning resulting in higher throughput of the imaging system. Because it is a widefield technique, the optical sectioning effect is considerably poorer than with conventional spatial focusing two-photon microscopy. Here we propose wide-field two-photon microscopy based on spatio-temporal focusing and employing background rejection based on the HiLo microscope principle. We demonstrate the effects of applying HiLo microscopy to widefield temporally focused two-photon microscopy.

  5. Focusing the photon dose in a head phantom

    International Nuclear Information System (INIS)

    Arkuszewski, J.

    1997-01-01

    The 30 keV photons stereotactic focusing is being examined for two kinds of collimated sources and it has been found less advantageous as compared to the gamma-knife MeV range. (author) 2 figs., 2 refs

  6. Fabrication of photonic crystals on several kinds of semiconductor materials by using focused-ion beam method

    International Nuclear Information System (INIS)

    Xu Xingsheng; Chen Hongda; Xiong Zhigang; Jin Aizi; Gu Changzhi; Cheng Bingying; Zhang Daozhong

    2007-01-01

    In this paper, we introduced the fabrication of photonic crystals on several kinds of semiconductor materials by using focused-ion beam machine, it shows that the method of focused-ion beam can fabricate two-dimensional photonic crystal and photonic crystal device efficiently, and the quality of the fabricated photonic crystal is high. Using the focused-ion beam method, we fabricate photonic crystal wavelength division multiplexer, and its characteristics are analyzed

  7. Disorders influences on the focusing effect of all-dielectric photonic crystal slab superlens

    Energy Technology Data Exchange (ETDEWEB)

    Hu Xiaoyong; Xin Cheng [State Key Laboratory for Mesoscopic Physics and Department of Physics, Peking University, Beijing 100871 (China); Gong Qihuang [State Key Laboratory for Mesoscopic Physics and Department of Physics, Peking University, Beijing 100871 (China)], E-mail: qhgong@pku.edu.cn

    2009-04-13

    The influences of structure disorders on the subwavelength focusing properties of an all-dielectric photonic crystal slab superlens are theoretically studied. The structure disorders are considered as randomly perturbing the position or diameter of air holes of the photonic crystal slab. The results show that the photonic crystal slab superlens can tolerate within 10% degree of positional disorder or 15% degree of diameter disorder without destroying the focusing function.

  8. Disorders influences on the focusing effect of all-dielectric photonic crystal slab superlens

    International Nuclear Information System (INIS)

    Hu Xiaoyong; Xin Cheng; Gong Qihuang

    2009-01-01

    The influences of structure disorders on the subwavelength focusing properties of an all-dielectric photonic crystal slab superlens are theoretically studied. The structure disorders are considered as randomly perturbing the position or diameter of air holes of the photonic crystal slab. The results show that the photonic crystal slab superlens can tolerate within 10% degree of positional disorder or 15% degree of diameter disorder without destroying the focusing function.

  9. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    International Nuclear Information System (INIS)

    Tuite, M.J.; Asinger, D.; Orwin, J.F.

    2001-01-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  10. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J; Asinger, D; Orwin, J F [Dept. of Radiology, Univ. of Wisconsin Hospital and Clinics, Madison, WI (United States)

    2001-05-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  11. The use of the T1 sagittal angle in predicting overall sagittal balance of the spine.

    Science.gov (United States)

    Knott, Patrick T; Mardjetko, Steven M; Techy, Fernando

    2010-11-01

    A balanced sagittal alignment of the spine has been shown to strongly correlate with less pain, less disability, and greater health status scores. To restore proper sagittal balance, one must assess the position of the occiput relative to the sacrum. The assessment of spinal balance preoperatively can be challenging, whereas predicting postoperative balance is even more difficult. This study was designed to evaluate and quantify multiple factors that influence sagittal balance. Retrospective analysis of existing spinal radiographs. A retrospective review of 52 adult spine patient records was performed. All patients had full-column digital radiographs that showed all the important skeletal landmarks necessary for accurate measurement. The average age of the patient was 53 years. Both genders were equally represented. The radiographs were measured using standard techniques to obtain the following parameters: scoliosis in the coronal plane; lordosis or kyphosis of the cervical, thoracic, and lumbar spine; the T1 sagittal angle (angle between a horizontal line and the superior end plate of T1); the angle of the dens in the sagittal plane; the angle of the dens in relation to the occiput; the sacral slope; the pelvic incidence; the femoral-sacral angle; and finally, the sagittal vertical axis (SVA) measured from both the dens of C2 and from C7. It was found that the SVA when measured from the dens was on average 16 mm farther forward than the SVA measured from C7 (p<.0001). The dens plumb line (SVA(dens)) was then used in the study. An analysis was done to examine the relationship between SVA(dens) and each of the other measurements. The T1 sagittal angle was found to have a moderate positive correlation (r=0.65) with SVA(dens), p<.0001, indicating that the amount of sagittal T1 tilt can be used as a good predictor of overall sagittal balance. When examining the other variables, it was found that cervical lordosis had a weak correlation (r=0.37) with SVA(dens) that was

  12. Sagittal crest formation in great apes and gibbons.

    Science.gov (United States)

    Balolia, Katharine L; Soligo, Christophe; Wood, Bernard

    2017-06-01

    The frequency of sagittal crest expression and patterns of sagittal crest growth and development have been documented in hominoids, including some extinct hominin taxa, and the more frequent expression of the sagittal crest in males has been traditionally linked with the need for larger-bodied individuals to have enough attachment area for the temporalis muscle. In the present study, we investigate sagittal cresting in a dentally mature sample of four hominoid taxa (Pan troglodytes schweinfurthii, Gorilla gorilla gorilla, Pongo pygmaeus pygmaeus and Hylobates lar). We investigate whether sagittal crest size increases with age beyond dental maturity in males and females of G. g. gorilla and Po. pyg. pygmaeus, and whether these taxa show sex differences in the timing of sagittal crest development. We evaluate the hypothesis that the larger sagittal crest of males may not be solely due to the requirement for a larger surface area than the un-crested cranial vault can provide for the attachment of the temporalis muscle, and present data on sex differences in temporalis muscle attachment area and sagittal crest size relative to cranial size. Gorilla g. gorilla and Po. pyg. pygmaeus males show significant relationships between tooth wear rank and sagittal crest size, and they show sagittal crest size differences between age groups that are not found in females. The sagittal crest emerges in early adulthood in the majority of G. g. gorilla males, whereas the percentage of G. g. gorilla females possessing a sagittal crest increases more gradually. Pongo pyg. pygmaeus males experience a three-fold increase in the number of specimens exhibiting a sagittal crest in mid-adulthood, consistent with a secondary growth spurt. Gorilla g. gorilla and Po. pyg. pygmaeus show significant sex differences in the size of the temporalis muscle attachment area, relative to cranial size, with males of both taxa showing positive allometry not shown in females. Gorilla g

  13. Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients

    Science.gov (United States)

    Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul

    2013-01-01

    In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276

  14. Sagittal crest formation in great apes and gibbons

    OpenAIRE

    Balolia, K. L.; Soligo, C.; Wood, B.

    2017-01-01

    The frequency of sagittal crest expression and patterns of sagittal crest growth and development have been documented in hominoids, including some extinct hominin taxa, and the more frequent expression of the sagittal crest in males has been traditionally linked with the need for larger-bodied individuals to have enough attachment area for the temporalis muscle. In the present study, we investigate sagittal cresting in a dentally mature sample of four hominoid taxa (Pan troglodytes schweinfur...

  15. Analysis of sagittal spinopelvic parameters in achondroplasia.

    Science.gov (United States)

    Hong, Jae-Young; Suh, Seung-Woo; Modi, Hitesh N; Park, Jong-Woong; Park, Jung-Ho

    2011-08-15

    Prospective radiological analysis of patients with achondroplasia. To analyze sagittal spinal alignment and pelvic orientation in achondroplasia patients. Knowledge of sagittal spinopelvic parameters is important for the treatment of achondroplasia, because they differ from those of the normal population and can induce pain. The study and control groups were composed of 32 achondroplasia patients and 24 healthy volunteers, respectively. All underwent lateral radiography of the whole spine including hip joints. The radiographic parameters examined were sacral slope (SS), pelvic tilt, pelvic incidence (PI), S1 overhang, thoracic kyphosis, T10-L2 kyphosis, lumbar lordosis (LL1, LL2), and sagittal balance. Statistical analysis was performed to identify significant differences between the two groups. In addition, correlations between parameters and symptoms were sought. Sagittal spinopelvic parameters, namely, pelvic tilt, pelvic incidence, S1 overhang, thoracic kyphosis, T10-L2 kyphosis, lumbar lordosis 1 and sagittal balance were found to be significantly different in the patient and control groups (P achondroplasia patients and normal healthy controls. The present study shows that sagittal spinal and pelvic parameters can assist the treatment of spinal disorders in achondroplasia patients.

  16. Fast and accurate focusing analysis of large photon sieve using pinhole ring diffraction model.

    Science.gov (United States)

    Liu, Tao; Zhang, Xin; Wang, Lingjie; Wu, Yanxiong; Zhang, Jizhen; Qu, Hemeng

    2015-06-10

    In this paper, we developed a pinhole ring diffraction model for the focusing analysis of a large photon sieve. Instead of analyzing individual pinholes, we discuss the focusing of all of the pinholes in a single ring. An explicit equation for the diffracted field of individual pinhole ring has been proposed. We investigated the validity range of this generalized model and analytically describe the sufficient conditions for the validity of this pinhole ring diffraction model. A practical example and investigation reveals the high accuracy of the pinhole ring diffraction model. This simulation method could be used for fast and accurate focusing analysis of a large photon sieve.

  17. Sagittal x-ray beam deviation at asymmetric inclined diffractors

    Czech Academy of Sciences Publication Activity Database

    Korytár, D.; Hrdý, Jaromír; Artemiev, Nikolai; Ferrari, C.; Freund, A.

    2001-01-01

    Roč. 8, - (2001), s. 1136-1139 ISSN 0909-0495 R&D Projects: GA MŠk OK 305; GA MPO PZ-CH/22 Institutional research plan: CEZ:AV0Z1010914 Keywords : x-ray optics * Si(111) W/grooved crystals * inclined diffraction * out-of-diffraction-plane beams * sagittal focusing Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.519, year: 2001

  18. Strategic Considerations for Effective Sagittal Resection of the Mandible to Achieve a Slim and Attractive Jawline.

    Science.gov (United States)

    Park, Sanghoon; Lee, Tae Sung

    2018-01-01

    Sagittal resection of the mandible has been widely used to reduce the width of the lower face and is usually carried out in combination with a mandibular contouring procedure. However, the surgical outcomes of this procedure are unclear because sagittal resection is rarely performed as a single procedure. The authors clarify misunderstandings regarding this procedure and introduce an improved strategic approach for sagittal resection of the mandible. Under general anesthesia, mandible contouring was performed first with a curved osteotomy, followed by sagittal resection of the outer cortex of mandible. The amount and extent of each procedure was determined in accordance with preoperative analysis. From 2012 to 2014, a consecutive series of 212 patients who underwent mandible contouring surgery without concomitant chin surgery were included in the study. A total of 189 patients underwent both mandibular contouring surgery and sagittal resection, whereas 13 underwent only sagittal resection and 10 underwent only mandibular contouring surgery. All operations were carried out successfully without any severe complications, and most patients had satisfactory aesthetic outcomes. The authors found that the sagittal resection of the mandible should be performed in accordance with the shape of the mandible to effectively reduce facial width and achieve better aesthetic outcomes for both profile and frontal views. In an outcurved-type mandible, conventional mandibular contouring may be effective alone, whereas sagittal resection focusing on removing the mandible body region is essential for incurved-type mandibles. In straight line-type mandibles, both procedures are necessary. Therapeutic, IV.

  19. Focused-ion-beam nano-structuring of photonic cavities in dielectric materials

    NARCIS (Netherlands)

    Ay, F.; Pollnau, Markus

    Focused ion beam (FIB) milling is an emerging technology that enables fast, reliable and well-controlled nanometer-size feature definition. In this work we will discuss applications of the tool in the area of photonics. The FIB technique can be adapted and optimized almost for any material system

  20. The focusing effect of electromagnetic waves in two-dimensional photonic crystals with gradually varying lattice constant

    Directory of Open Access Journals (Sweden)

    F Bakhshi Garmi

    2016-02-01

    Full Text Available In this paper we studied the focusing effect of electromagnetic wave in the two-dimensional graded photonic crystal consisting of Silicon rods in the air background with gradually varying lattice constant. The results showed that graded photonic crystal can focus wide beams on a narrow area at frequencies near the lower edge of the band gap, where equal frequency contours are not concave. For calculation of photonic band structure and equal frequency contours, we have used plane wave expansion method and revised plane wave expansion method, respectively. The calculation of the electric and magnetic fields was performed by finite difference time domain method.

  1. The usefulness of sagittal reformation for diagnosis of sternal fracture

    Energy Technology Data Exchange (ETDEWEB)

    Im, Dong Jin; Hahn, Seok; Kim, Young Ju [Dept. of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju (Korea, Republic of)

    2014-01-15

    The purpose of our study was to evaluate the usefulness of sagittal reformation of chest computed tomography for the diagnosis of sternal fracture after trauma. We retrospectively reviewed medical records and chest computer tomography (CT) of 716 patients in the emergency department after trauma between January and December 2010. Two radiologists investigated chest CT images. We investigated numbers and locations of sternal fractures on axial images only and on both axial and sagittal images for each radiologist. First, radiologist found sternal fractures in 58 patients (70.7%) on only axial images, and 80 (97.5%) on both axial and sagittal images. Second, radiologist found fractures in 67 patients (81.7%) on axial image only and 81 (98.7%) on both axial and sagittal images. The sensitivity increased after adding sagittal reformation images for each radiologist (p < 0.05, respectively). On the axial images, the interobserver agreement was low (k 0.596) between the two radiologists. However, on both axial and sagittal images, the interobserver agreement increased (k = 0.872). Sagittal reformation of chest CT increases the chance of diagnosis for sternal fracture and leads to early diagnosis resulting in appropriate treatment.

  2. The usefulness of sagittal reformation for diagnosis of sternal fracture

    International Nuclear Information System (INIS)

    Im, Dong Jin; Hahn, Seok; Kim, Young Ju

    2014-01-01

    The purpose of our study was to evaluate the usefulness of sagittal reformation of chest computed tomography for the diagnosis of sternal fracture after trauma. We retrospectively reviewed medical records and chest computer tomography (CT) of 716 patients in the emergency department after trauma between January and December 2010. Two radiologists investigated chest CT images. We investigated numbers and locations of sternal fractures on axial images only and on both axial and sagittal images for each radiologist. First, radiologist found sternal fractures in 58 patients (70.7%) on only axial images, and 80 (97.5%) on both axial and sagittal images. Second, radiologist found fractures in 67 patients (81.7%) on axial image only and 81 (98.7%) on both axial and sagittal images. The sensitivity increased after adding sagittal reformation images for each radiologist (p < 0.05, respectively). On the axial images, the interobserver agreement was low (k 0.596) between the two radiologists. However, on both axial and sagittal images, the interobserver agreement increased (k = 0.872). Sagittal reformation of chest CT increases the chance of diagnosis for sternal fracture and leads to early diagnosis resulting in appropriate treatment.

  3. Acute proximal junctional failure in patients with preoperative sagittal imbalance.

    Science.gov (United States)

    Smith, Micah W; Annis, Prokopis; Lawrence, Brandon D; Daubs, Michael D; Brodke, Darrel S

    2015-10-01

    Proximal junctional failure (PJF) is a recognized complication of spinal deformity surgery. Acute PJF (APJF) has recently been demonstrated to be 5.6% in the adult spinal deformity (ASD) population. The incidence and rate of return to the operating room for APJF have not been specifically investigated in individuals with sagittal imbalance. The purpose of this study was to report the incidence of APJF in patients with preoperative sagittal imbalance and the rate of return to the operating room for APJF. This study is based on a retrospective review of prospectively collected database of ASD patients. One hundred seventy-three consecutive patients were included with preoperative sagittal imbalance according to one of the following common parameters: sagittal vertical axis (SVA) greater than 50 mm, global sagittal alignment greater than 45°, or pelvic incidence minus lumbar lordosis greater than 10°. Outcome measure was presence and/or absence of APJF defined as fracture at the upper instrumented vertebra (UIV) or UIV+1, failure of UIV fixation, 15° or more proximal junctional kyphosis, or need for extension of instrumentation within 6 months of surgery. We performed radiographic measurements on X-rays at preoperative, immediate postoperative, and 6-month follow-up visits. The APJF rate was reported for the entire patient population with preoperative sagittal imbalance. Acute PJF incidence was calculated postoperatively for each of the accepted sagittal balance parameters and/or formulas. Patients with persistent postoperative sagittal imbalance were compared with the sagittally balanced group. We also assessed for threshold values. Acute PJF was observed in 60 of 173 patients (35%) and was least common in fusions with the UIV in the upper thoracic (UT) spine (p=.035). Of those who developed APJF, 21.7% required surgery. Proximal junctional kyphosis 15° or more was the most common form of APJF in fusions to the UT spine but least likely to need revision (p=.014

  4. FUNCTIONAL DISABILITY, SAGITTAL ALIGNMENT AND PELVIC BALANCE IN LUMBAR SPONDYLOLISTHESIS

    Directory of Open Access Journals (Sweden)

    Luis Muñiz Luna

    2016-03-01

    Full Text Available ABSTRACT Objectives: To demonstrate the recovery of lumbar sagittal pelvic alignment and sagittal pelvic balance after surgical reduction of lumbar spondylolisthesis and establish the benefits of the surgery for reduction and fixation of the lumbar spondylolisthesis with 360o circumferential arthrodesis for 2 surgical approaches by clinical and functional evaluation. Method: Eight patients with lumbar spondylolisthesis treated with surgical reduction and fixation of listhesis and segmental circumferential fusion with two surgical approaches were reviewed. They were evaluated before and after treatment with Oswestry, Visual Analogue for pain and Odom scales, performing radiographic measurement of lumbar sagittal alignment and pelvic sagittal balance with the technique of pelvic radius. Results: Oswestry scales and EVA reported improvement of symptoms after treatment in 8 cases; the Odom scale had six outstanding cases reported. The lumbar sagittal alignment presented a lumbosacral lordosis angle and a lumbopelvic lordosis angle reduced in 4 cases and increased in 4 other cases; pelvic sagittal balance increased the pelvic angle in 4 cases and decreased in 3 cases and the sacral translation of the hip axis to the promontory increased in 6 cases. Conclusion: The surgical procedure evaluated proved to be useful by modifying the lumbar sagittal alignment and the pelvic balance, besides reducing the symptoms, enabling the patient to have mobility and movement and the consequent satisfaction with the surgery.

  5. Reliability of cervical lordosis and global sagittal spinal balance measurements in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Vidal, Christophe; Ilharreborde, Brice; Azoulay, Robin; Sebag, Guy; Mazda, Keyvan

    2013-06-01

    Radiological reproducibility study. To assess intra and interobserver reliability of radiographic measurements for global sagittal balance parameters and sagittal spine curves, including cervical spine. Sagittal spine balance in adolescent idiopathic scoliosis (AIS) is a main issue and many studies have been reported, showing that coronal and sagittal deformities often involve sagittal cervical unbalance. Global sagittal balance aims to obtain a horizontal gaze and gravity line at top of hips when subject is in a static position, involving adjustment of each spine curvature in the sagittal plane. To our knowledge, no study did use a methodologically validated imaging analysis tool able to appreciate sagittal spine contours and distances in AIS and especially in the cervical region. Lateral full-spine low-dose EOS radiographs were performed in 75 patients divided in three groups (control subjects, AIS, operated AIS). Three observers digitally analyzed twice each radiograph and 11 sagittal measures were collected for each image. Reliability was assessed calculating intraobserver Pearson's r correlation coefficient, interobserver intra-class correlation coefficient (ICC) completed with a two-by-two Bland-Altman plot analysis. This measurement method has shown excellent intra and interobserver reliability in all parameters, sagittal curvatures, pelvic parameters and global sagittal balance. This study validated a simple and efficient tool in AIS sagittal contour analysis. It defined new relevant landmarks allowing to characterize cervical segmental curvatures and cervical involvement in global balance.

  6. Back to the future: sagittal CT in the evaluation of COPD

    International Nuclear Information System (INIS)

    Hightower, Jessica S.; Amadi, Chiemezie; Den, Elana; Schmitt, James E.; Shah, Rosita M.; Miller, Wallace T.

    2016-01-01

    To identify features of obstructive airway disease on sagittal reconstruction, compare the accuracy of findings to traditional imaging characteristics of COPD, and determine the fraction of additional cases identified using new characteristics. The study was approved by the centre's Institutional Review Board and is HIPAA compliant. Two hundred sixteen patients with HRCT and spirometry within a 3-month window were included. Four radiologists evaluated each HRCT for traditional characteristics of COPD and new quantitative and qualitative features of obstruction on axial and sagittal reconstructions. Imaging characteristics were assessed for correlation with the spirometric diagnosis of obstructive airway disease. Quantitative and qualitative findings on sagittal reconstruction are highly specific for COPD (specificity >90 %). Features of hyperinflation on sagittal reconstruction are more accurate predictors of obstruction than traditional axial measures, with greater interobserver reliability (hyperinflation left hemidiaphragm: accuracy: 70.08 % ± 2.49 %; kappa: 0.511 versus traditional measures: accuracy: 62.00 % ± 5.38 %; kappa: 0.407). Sagittal reconstruction identified 27-70 % more patients with COPD than traditional axial findings (p < 0.05). Analysis of sagittal reconstruction enables greater accuracy and specificity in the diagnosis of obstructive airway disease compared to traditional measures on axial imaging. Use of sagittal reconstructions can help identify up to 70 % more patients with COPD than traditional imaging findings alone. (orig.)

  7. Anthropometric outcome of sagittal craniosynostosis following surgery

    International Nuclear Information System (INIS)

    Takagi, Toshinori; Morota, Nobuhito; Ihara, Satoshi; Kaneko, Tsuyoshi

    2011-01-01

    Several studies have shown good short-term outcomes after surgery for sagittal synostosis. However, the improvement in head shape usually regresses over the long term. The aim of this study was to compare anthropometric changes after surgery between osteoplastic expansion surgery and distraction osteogenesis for correcting sagittal synostosis. From November 2002 through December 2008, 17 patients with sagittal synostosis were analyzed. Anthropometric changes were assessed with cephalic indices obtained with computed tomography of the skull. The age of the patients at the time of surgery ranged from 2 to 25 months (mean, 8.2 months), and the follow-up period ranged from 6 to 63 months (mean, 17 months). In 16 patients, the cephalic index showed improvement immediately after surgery but gradually decreased in the follow-up period. The improving rate was decreased more after osteoplastic expansion surgery than after distraction osteogenesis (p<0.01). Although long-term follow-up is necessary, morphological improvement persists to a greater degree after distraction surgery. (author)

  8. Pedicle subtraction osteotomy in elderly patients with degenerative sagittal imbalance.

    Science.gov (United States)

    Cho, Kyu-Jung; Kim, Ki-Tack; Kim, Whoan-Jeang; Lee, Sang-Hoon; Jung, Jae-Hoon; Kim, Young-Tae; Park, Hae-Bong

    2013-11-15

    Retrospective, radiographical analysis. To evaluate pedicle subtraction osteotomy (PSO) as a means of correcting severe degenerative sagittal imbalance in elderly patients. PSO in patients with degenerative sagittal imbalance is likely to cause more complications than in patients with iatrogenic flatback deformity. This study analyzed 34 patients who underwent fusion to the sacrum, with a minimum 2-year follow-up. Age of the patients were in the range from 58 to 73 with the mean at 65.5 years. PSO was performed at one segment in all cases, consisting of L3 (n = 26), L4 (n = 4), L2 (n = 3), and L1 (n = 1). The average number of levels fused was 8.15. Ten patients had structural interbody fusion at the lumbosacral junction. Applying PSO at one segment, the mean correction of the lordotic angle at the osteotomy site was 33.3°, of which the loss of correction (LOC) was 4.0° at the last visit. The correction of lumbar lordosis was 33.7° and the LOC was 8.5°. The sagittal C7 plumb was 215.9 mm before surgery, corrected to 35.1 mm after surgery, and changed to 95.9 mm by the last visit. The correction of the sagittal C7 plumb was 119.9 mm and the LOC was 60.9 mm. There was substantial LOC in lumbar lordosis and sagittal C7 plumb. In 10 patients with addition of posterior lumbar interbody fusion, the LOC of lumbar lordosis was 7.4°, which was less than 9° in those without it. PSO for the correction of degenerative sagittal imbalance in elderly patients resulted in correction of sagittal alignment with a significant LOC of lumbar lordosis and sagittal C7 plumb. The LOC of lumbar lordosis occurred at both the osteotomy and non-osteotomy site. The addition of anterior column support is helpful to maintain correction and reduce complications. N/A.

  9. Walking sagittal balance correction by pedicle subtraction osteotomy in adults with fixed sagittal imbalance.

    Science.gov (United States)

    Yagi, Mitsuru; Kaneko, Shinjiro; Yato, Yoshiyuki; Asazuma, Takashi; Machida, Masafumi

    2016-08-01

    Pedicle subtraction osteotomy (PSO) is widely used to treat severe fixed sagittal imbalance. However, the effect of PSO on balance has not been fully documented. The aim of this study was to assess dynamic walking balance after PSO to treat fixed sagittal imbalance. Gait and balance were assessed in 15 consecutive adult female patients who had been treated by PSO for a fixed sagittal imbalance and compare patients' preop and postop dynamic walking balance with that of 15 age- and gender-matched healthy volunteers (HV). Each patient's chart, X-rays, pre and postop SRS22 outcome scores, and ODI were reviewed. Means were compared by Mann-Whitney U test and Chi-square test. The mean age was 66.3 years (51-74 years). The mean follow-up was 2.7 years (2-3.5 years). The C7PL and GL, measured on the force platform, were both improved from 24.2 ± 7.3 cm and 27.6 ± 9.4 to 5.4 ± 2.6 cm and 7.2 ± 3.4 cm, respectively. The baseline hip ROM was significantly smaller in patients compared to HV, whereas no significant difference was observed in the knee or ankle ROM. The pelvic tilt (preop -0.4° ± 1.4°, postop 8.9° ± 1.0°), and maximum hip-extension angle (preop -1.2° ± 14.2°, postop -11.2° ± 7.2°) were also improved after surgery. Cadence (116 s/min), stance-swing ratio (stance 63.2 % vs. swing 36.8 %), and stride (98.0 cm) were all increased after surgery. On the other hand, gait velocity was significantly slower in the PSO group at both pre and postop than in HV (PSO 53.3 m/min at preop and 58.8 m/min at postop vs. HV 71.1 m/min, p = 0.04). Despite a mild residual spinal-pelvic malalignment, PSO restored sagittal alignment and balance satisfactorily and has improved the gait pattern.

  10. Lenke 1 and 5: changes in sagittal balance

    Directory of Open Access Journals (Sweden)

    Delson Valdemir Pessin

    2014-09-01

    Full Text Available OBJECTIVE: To assess in a cross-sectional study whether there are changes in sagittal balance in patients with adolescent idiopathic scoliosis Lenke types 1 and 5 compared with patients without pathology of the spine and compare the values of the parameters of normal subjects with the parameters found in the literature. METHODS: We measured the values of the parameters of sagittal balance of 21 patients with scoliosis and 14 patients without scoliosis in panoramic radiographs or simply collected data previously measured from the medical records. We compared the mean values of normal subjects, the mean values found in the literature, and the means between normal subjects and patients with scoliosis. For this, we used the Student t test. RESULTS: Using a confidence interval of 5% (p < 0.05 and the Student t test we obtained statistical significance in the comparison of two parameters of sagittal balance between normal subjects and patients with scoliosis. We observed similarities in the measurements of the average parameters of normal subjects with regard to the work already published. CONCLUSIONS: The adolescent idiopathic scoliosis causes changes in two parameters of sagittal balance with statistical significance but suggests changes in all other parameters. As for comparison with previously published work, the results were similar.

  11. Effect of the defect on the focusing in a two-dimensional photonic-crystal-based flat lens

    International Nuclear Information System (INIS)

    Feng Zhifang; Wang Xiuguo; Li Zhiyuan; Zhang Daozhong

    2008-01-01

    We have investigated in detail the influence of defect on the focusing of electromagnetic waves in a two-dimensional photonic-crystal flat lens by using the finite-difference time-domain method. The result shows that many focusings can be observed at the symmetrical positions when a defect is introduced into the lens. Furthermore, the wave-guides in the lens can confine the transmission wave effectively and improve the quality of the focusing

  12. At wavelength focusing properties evaluation of the Wolter type grazing incidence mirror

    CERN Document Server

    Takeuchi, A; Uesugi, K; Aoki, S

    2001-01-01

    Focusing properties of a Wolter mirror were evaluated in a hard X-ray region (approx 10 keV). Although the sagittal focal spot size was found to be 0.7 mu m, some spots are spread in meridional direction within a range of over 100 mu m. A Foucault-test method has been employed for closer investigation of the focusing properties. Wave-front of the sagittal focusing rays was almost ideal. On the contrary, it was found that slope error of about 100-300 mu rad existed for the meridional focusing.

  13. Theory of the effect of third-harmonic generation on three-photon resonantly enhanced multiphoton ionization in focused beams

    International Nuclear Information System (INIS)

    Payne, M.G.; Garrett, W.R.

    1983-01-01

    Multiphoton ionization in the region near a three-photon resonance is treated for focused, plane-polarized Gaussian beams with diffraction-limited beam divergence. In this situation, a third-harmonic field is generated within the laser beam. At, and very near, three-photon resonance the driving rate for the upper-state probability amplitude due to one-photon absorption of third-harmonic light becomes nearly equal to the corresponding three-photon rate due to the laser field, but these effects are 180 0 out of phase. As a consequence of this cancellation between two pumping terms, the three-photon resonance line essentially disappears at moderate concentrations and the observed ionization has a line shape that is close to the phase-matching curve for third-harmonic generation. The ionization signal, near but not on the resonance, is due almost entirely to absorption of third-harmonic photons plus other laser photons; three-photon resonantly enhanced multiphoton ionization by the laser is much weaker. This is particularly true on the blue side of the three-photon resonance at detunings where phase matching occurs. The problem is treated quite generally with predictions of the full line shape for n-photon ionization and third-harmonic light generation near three-photon resonance, including the rather strong influences of positively dispersive buffer gases. We also show that the cancellation between the one-photon and the three-photon process is partially spoiled in the presence of a counterpropagating beam at the same frequency

  14. Photon-photon colliders

    International Nuclear Information System (INIS)

    Sessler, A.M.

    1995-04-01

    Since the seminal work by Ginsburg, et at., the subject of giving the Next Linear Collider photon-photon capability, as well as electron-positron capability, has drawn much attention. A 1990 article by V.I. Teinov describes the situation at that time. In March 1994, the first workshop on this subject was held. This report briefly reviews the physics that can be achieved through the photon-photon channel and then focuses on the means of achieving such a collider. Also reviewed is the spectrum of backscattered Compton photons -- the best way of obtaining photons. We emphasize the spectrum actually obtained in a collider with both polarized electrons and photons (peaked at high energy and very different from a Compton spectrum). Luminosity is estimated for the presently considered colliders, and interaction and conversion-point geometries are described. Also specified are laser requirements (such as wavelength, peak power, and average power) and the lasers that might be employed. These include conventional and free-electron lasers. Finally, we describe the R ampersand D necessary to make either of these approaches viable and explore the use of the SLC as a test bed for a photon-photon collider of very high energy

  15. Direct coronary and sagittal computerized tomography of the pelvis

    International Nuclear Information System (INIS)

    Maier, W.; Bargon, G.

    1981-01-01

    Whereas quite a number of reports have been published on direct coronary and sagittal computed tomography of the cranium, no extensive experience has been collected on multidimensional computerized tomography of the pelvis. In this article, the authors report on their preliminary experiences in direct approximately sagittal and coronary computerized tomography of the pelvis in a group of 76 patients. (orig.) [de

  16. Spinal Schmorl's nodes: Sagittal sectional imaging and pathological examination

    International Nuclear Information System (INIS)

    Silberstein, M.; Opeskin, K.

    1999-01-01

    The presence, location and number of Schmorl's nodes was determined in the thoracolumbar spines of 70 motor vehicle accident victims using radiographic examination of a midline sagittal section and subsequent pathological examinations, including histology. In 28% of spines, a greater number of Schmorl's nodes were identified with radiography, while in 44%, pathological examination revealed a greater number of nodes. The visibility of Schmorl's nodes was enhanced by using a sagittal radiographic approach, and, in contrast to previous work, nodes below 0.5 cm 2 were readily detected. The results of the present study offer an additional imaging technique for postmortem analysis of the spine, and support the use of sagittal MR imaging for the evaluation of this condition. Copyright (1999) Blackwell Science Pty Ltd

  17. Photon Collider Physics with Real Photon Beams

    International Nuclear Information System (INIS)

    Gronberg, J; Asztalos, S

    2005-01-01

    Photon-photon interactions have been an important probe into fundamental particle physics. Until recently, the only way to produce photon-photon collisions was parasitically in the collision of charged particles. Recent advances in short-pulse laser technology have made it possible to consider producing high intensity, tightly focused beams of real photons through Compton scattering. A linear e + e - collider could thus be transformed into a photon-photon collider with the addition of high power lasers. In this paper they show that it is possible to make a competitive photon-photon collider experiment using the currently mothballed Stanford Linear Collider. This would produce photon-photon collisions in the GeV energy range which would allow the discovery and study of exotic heavy mesons with spin states of zero and two

  18. Comparing temporally-focused GPC and CGH for two-photon excitation and optogenetics in turbid media

    DEFF Research Database (Denmark)

    Villangca, Mark Jayson; Bañas, Andrew Rafael; Aabo, Thomas

    2013-01-01

    a 4f setup that directly converts phase information to intensity. The GPC method has been used with temporal focusing for excitation in two-photon optogenetics [1-3]. The computer generated hologram (CGH) is also used to generate arbitrary light patterns and has been used for optical manipulation...

  19. Visible to Infrared Diamond Photonics Enabled by Focused Femtosecond Laser Pulses

    Directory of Open Access Journals (Sweden)

    Belén Sotillo

    2017-02-01

    Full Text Available Diamond’s nitrogen-vacancy (NV centers show great promise in sensing applications and quantum computing due to their long electron spin coherence time and because they can be found, manipulated, and read out optically. An important step forward for diamond photonics would be connecting multiple diamond NVs together using optical waveguides. However, the inertness of diamond is a significant hurdle for the fabrication of integrated optics similar to those that revolutionized silicon photonics. In this work, we show the fabrication of optical waveguides in diamond, enabled by focused femtosecond high repetition rate laser pulses. By optimizing the geometry of the waveguide, we obtain single mode waveguides from the visible to the infrared. Additionally, we show the laser writing of individual NV centers within the bulk of diamond. We use µ-Raman spectroscopy to gain better insight on the stress and the refractive index profile of the optical waveguides. Using optically detected magnetic resonance and confocal photoluminescence characterization, high quality NV properties are observed in waveguides formed in various grades of diamond, making them promising for applications such as magnetometry, quantum information systems, and evanescent field sensors.

  20. Influence of implant rod curvature on sagittal correction of scoliosis deformity.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2014-08-01

    Deformation of in vivo-implanted rods could alter the scoliosis sagittal correction. To our knowledge, no previous authors have investigated the influence of implanted-rod deformation on the sagittal deformity correction during scoliosis surgery. To analyze the changes of the implant rod's angle of curvature during surgery and establish its influence on sagittal correction of scoliosis deformity. A retrospective analysis of the preoperative and postoperative implant rod geometry and angle of curvature was conducted. Twenty adolescent idiopathic scoliosis patients underwent surgery. Average age at the time of operation was 14 years. The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. Two implant rods were attached to the concave and convex side of the spinal deformity. The preoperative implant rod geometry was measured before surgical implantation. The postoperative implant rod geometry after surgery was measured by computed tomography. The implant rod angle of curvature at the sagittal plane was obtained from the implant rod geometry. The angle of curvature between the implant rod extreme ends was measured before implantation and after surgery. The sagittal curvature between the corresponding spinal levels of healthy adolescents obtained by previous studies was compared with the implant rod angle of curvature to evaluate the sagittal curve correction. The difference between the postoperative implant rod angle of curvature and normal spine sagittal curvature of the corresponding instrumented level was used to evaluate over or under correction of the sagittal deformity. The implant rods at the concave side of deformity of all patients were significantly deformed after surgery. The average degree of rod deformation Δθ at the concave and convex sides was 15.8° and 1.6°, respectively. The average preoperative and postoperative implant rod angle of curvature at the concave side was 33.6° and 17.8

  1. Superior sagittal sinus thrombosis: a rare complication of nephrotic syndrome.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1999-10-01

    Full Text Available A two and half year-old-male child, known case of steroid responsive nephrotic syndrome presented with fever and vomiting of acute onset. He was diagnosed to have superior sagittal sinus thrombosis on a contrast computerised tomographic scan of brain. Recovery was complete without anticoagulant therapy. Superior sagittal sinus thrombosis is an extremely rare complication of nephrotic syndrome.

  2. FocusStack and StimServer: a new open source MATLAB toolchain for visual stimulation and analysis of two-photon calcium neuronal imaging data.

    Science.gov (United States)

    Muir, Dylan R; Kampa, Björn M

    2014-01-01

    Two-photon calcium imaging of neuronal responses is an increasingly accessible technology for probing population responses in cortex at single cell resolution, and with reasonable and improving temporal resolution. However, analysis of two-photon data is usually performed using ad-hoc solutions. To date, no publicly available software exists for straightforward analysis of stimulus-triggered two-photon imaging experiments. In addition, the increasing data rates of two-photon acquisition systems imply increasing cost of computing hardware required for in-memory analysis. Here we present a Matlab toolbox, FocusStack, for simple and efficient analysis of two-photon calcium imaging stacks on consumer-level hardware, with minimal memory footprint. We also present a Matlab toolbox, StimServer, for generation and sequencing of visual stimuli, designed to be triggered over a network link from a two-photon acquisition system. FocusStack is compatible out of the box with several existing two-photon acquisition systems, and is simple to adapt to arbitrary binary file formats. Analysis tools such as stack alignment for movement correction, automated cell detection and peri-stimulus time histograms are already provided, and further tools can be easily incorporated. Both packages are available as publicly-accessible source-code repositories.

  3. Reproduction of superior sagittal sinus animal model by bypass transplantation of biomaterial graft

    Directory of Open Access Journals (Sweden)

    Qing-yong LUO

    2011-03-01

    Full Text Available Objective To establish the beagles model of superior sagittal sinus bypass graft,and explore the feasibility of reconstruction of superior sagittal sinus with biomaterials using this model.Methods Eight adult male beagles(weight: 12.5-22.0kg were involved in the present study.The superior sagittal sinus was exposed and blocked via bone window,and then anastomosed side-to-end to the biomaterial graft under the dedicated microscope of neurosurgery surgery,expectant treatment such as anti-inflammatory was given for the animals.The digital subtraction venography(DSV and color Doppler flow imaging(CDFI of superior sagittal sinus were performed in 1,2,4 and 8 weeks after the operation.Eight weeks after the operation,all the animals were sacrificed and the material graft was examined histologically.Results The DSV and CDFI of superior sagittal sinus showed that the stomas of 2 beagles were with slight stenosis and high flow velocity,of 1 beagle with small leakage and low flow velocity,while of other 5 beagles were normal.The histological examination showed endothelial cells were growing on the graft and superior sagittal sinus,and crawling toward the lumen of graft 8 weeks after the operation.Conclusion The beagles model of superior sagittal sinus bypass graft was established successfully.The short-term effect of the model was satisfactory,while further work should be performed to determine the long-term effects.

  4. Zebrin II Is Expressed in Sagittal Stripes in the Cerebellum of Dragon Lizards (Ctenophorus sp.).

    Science.gov (United States)

    Wylie, Douglas R; Hoops, Daniel; Aspden, Joel W; Iwaniuk, Andrew N

    2016-01-01

    Aldolase C, also known as zebrin II (ZII), is a glycolytic enzyme that is expressed in cerebellar Purkinje cells of the vertebrate cerebellum. In both mammals and birds, ZII is expressed heterogeneously, such that there are sagittal stripes of Purkinje cells with high ZII expression (ZII+) alternating with stripes of Purkinje cells with little or no expression (ZII-). In contrast, in snakes and turtles, ZII is not expressed heterogeneously; rather all Purkinje cells are ZII+. Here, we examined the expression of ZII in the cerebellum of lizards to elucidate the evolutionary origins of ZII stripes in Sauropsida. We focused on the central netted dragon (Ctenophorus nuchalis) but also examined cerebellar ZII expression in 5 other dragon species (Ctenophorus spp.). In contrast to what has been observed in snakes and turtles, we found that in these lizards, ZII is heterogeneously expressed. In the posterior part of the cerebellum, on each side of the midline, there were 3 sagittal stripes consisting of Purkinje cells with high ZII expression (ZII+) alternating with 2 sagittal stripes with weaker ZII expression (ZIIw). More anteriorly, most of the Purkinje cells were ZII+, except laterally, where the Purkinje cells did not express ZII (ZII-). Finally, all Purkinje cells in the auricle (flocculus) were ZII-. Overall, the parasagittal heterogeneous expression of ZII in the cerebellum of lizards is similar to that in mammals and birds, and contrasts with the homogenous ZII+ expression seen in snakes and turtles. We suggest that a sagittal heterogeneous expression of ZII represents the ancestral condition in stem reptiles which was lost in snakes and turtles. © 2017 S. Karger AG, Basel.

  5. Mid-sagittal plane and mid-sagittal surface optimization in brain MRI using a local symmetry measure

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Skoglund, Karl; Ryberg, Charlotte

    2005-01-01

    , the mid-sagittal plane is not always planar, but a curved surface resulting in poor partitioning of the brain hemispheres. To account for this, this paper also investigates an optimization strategy which fits a thin-plate spline surface to the brain data using a robust least median of squares estimator...

  6. Sagittal synostosis in X-linked hypophosphatemic rickets and related diseases

    Energy Technology Data Exchange (ETDEWEB)

    Currarino, Guido [Texas Scottish Rite Hospital, Department of Radiology, Dallas, TX (United States)

    2007-08-15

    The recent observations of two new cases of X-linked hypophosphatemic rickets associated with premature closure of the sagittal suture prompted a review of similar cases seen in this institution. To review the clinical records and skull radiographs of 28 children with hypophosphatemic rickets in order to investigate the frequency and type of craniosynostosis and other cranial vault changes seen in these conditions and to review the literature for relevant findings. Clinical and imaging records were reviewed on 28 patients with hypophosphatemic rickets, all younger than 18 years. Most patients had X-linked hypophosphatemic rickets and a few had autosomal-dominant hypophosphatemic rickets or were non-familial cases. Of the 28 patients, 13 had sagittal synostosis. Dolichocephaly was present in ten patients. The configuration of the cranial vault in some of these ten patients with dolichocephaly varied somewhat from that seen in nonsyndromic sagittal synostosis. In one patient, a Chiari I malformation was demonstrated by MRI. In another patient with increased intracranial pressure the sagittal suture closure was associated with lambdoidal synostosis. Dolichocephaly was not present in three patients, suggesting that the synostosis started later than in the other patients, probably in the second year of life, a period of slower brain growth than in the first year. The two patients in this group of three showed thickening and sclerosis of the cranial vault of uncertain etiology. There is an increased risk of sagittal synostosis in hypophosphatemic rickets and related diseases in children. The appearance of the cranial vault in this type of synostosis can vary from that seen in nonsyndromic synostosis. In this setting, careful clinical and imaging follow-up is warranted. (orig.)

  7. Sagittal synostosis in X-linked hypophosphatemic rickets and related diseases

    International Nuclear Information System (INIS)

    Currarino, Guido

    2007-01-01

    The recent observations of two new cases of X-linked hypophosphatemic rickets associated with premature closure of the sagittal suture prompted a review of similar cases seen in this institution. To review the clinical records and skull radiographs of 28 children with hypophosphatemic rickets in order to investigate the frequency and type of craniosynostosis and other cranial vault changes seen in these conditions and to review the literature for relevant findings. Clinical and imaging records were reviewed on 28 patients with hypophosphatemic rickets, all younger than 18 years. Most patients had X-linked hypophosphatemic rickets and a few had autosomal-dominant hypophosphatemic rickets or were non-familial cases. Of the 28 patients, 13 had sagittal synostosis. Dolichocephaly was present in ten patients. The configuration of the cranial vault in some of these ten patients with dolichocephaly varied somewhat from that seen in nonsyndromic sagittal synostosis. In one patient, a Chiari I malformation was demonstrated by MRI. In another patient with increased intracranial pressure the sagittal suture closure was associated with lambdoidal synostosis. Dolichocephaly was not present in three patients, suggesting that the synostosis started later than in the other patients, probably in the second year of life, a period of slower brain growth than in the first year. The two patients in this group of three showed thickening and sclerosis of the cranial vault of uncertain etiology. There is an increased risk of sagittal synostosis in hypophosphatemic rickets and related diseases in children. The appearance of the cranial vault in this type of synostosis can vary from that seen in nonsyndromic synostosis. In this setting, careful clinical and imaging follow-up is warranted. (orig.)

  8. Sagittal synostosis: I. Preoperative morphology of the skull

    DEFF Research Database (Denmark)

    Guimaraes-Ferreira, J.; Gewalli, F.; David, L.

    2006-01-01

    The aim of this study was to characterise the preoperative morphology of the skull in sagittal synostosis in an objective and quantified way. The shapes of the skulls of 105 patients with isolated premature synostosis of the sagittal suture ( SS group) were studied and compared with those......, skull base, and orbit ( 42 in the lateral and 46 in the frontal projections), the production of plots of mean shape for each group, and the intergroup comparison of a series of 81 variables ( linear distance between selected landmarks, and angles defined by groups of three landmarks). Data from...... skull width. Comparison of the mean values of an SS subgroup to age-matched normative data showed a longer (p differ significantly...

  9. Training intensity and sagittal curvature of the spine in male and female artistic gymnasts.

    Science.gov (United States)

    Sanz-Mengibar, Jose M; Sainz-de-Baranda, Pilar; Santonja-Medina, Fernando

    2018-04-01

    Specific adaptations of the spine in the sagittal plane have been described according to different sports disciplines. The goal of this study was to describe the integrative diagnosis of the sagittal morphotype of the spine in male and female artistic gymnasts. Forty-eight gymnasts were measured with an inclinometer. Thoracic and lumbar curves were quantified in standing position, in Sit and Reach and Slump Sitting in order to assess the sagittal spine posture and analyze if adaptations were related to training intensity. Correlation values of the sagittal plane spine measurements showed significantly increased thoracic kyphosis in men (-0.445, Partistic gymnastics; however, this sport seems to cause specific adaptations in postural hypolordosis, functional thoracic kyphosis and lumbar kyphotic attitude during sitting and trunk flexion. The implications of the functional adaptations observed in our results may require a preventive intervention in male and female artistic gymnasts can be assessed with the integrative diagnosis of the sagittal morphotype of the spine.

  10. Sagittal imbalance in patients with lumbar spinal stenosis and outcomes after simple decompression surgery.

    Science.gov (United States)

    Shin, E Kyung; Kim, Chi Heon; Chung, Chun Kee; Choi, Yunhee; Yim, Dahae; Jung, Whei; Park, Sung Bae; Moon, Jung Hyeon; Heo, Won; Kim, Sung-Mi

    2017-02-01

    Lumbar spinal stenosis (LSS) is the most common lumbar degenerative disease, and sagittal imbalance is uncommon. Forward-bending posture, which is primarily caused by buckling of the ligamentum flavum, may be improved via simple decompression surgery. The objectives of this study were to identify the risk factors for sagittal imbalance and to describe the outcomes of simple decompression surgery. This is a retrospective nested case-control study PATIENT SAMPLE: This was a retrospective study that included 83 consecutive patients (M:F=46:37; mean age, 68.5±7.7 years) who underwent decompression surgery and a minimum of 12 months of follow-up. The primary end point was normalization of sagittal imbalance after decompression surgery. Sagittal imbalance was defined as a C7 sagittal vertical axis (SVA) ≥40 mm on a 36-inch-long lateral whole spine radiograph. Logistic regression analysis was used to identify the risk factors for sagittal imbalance. Bilateral decompression was performed via a unilateral approach with a tubular retractor. The SVA was measured on serial radiographs performed 1, 3, 6, and 12 months postoperatively. The prognostic factors for sagittal balance recovery were determined based on various clinical and radiological parameters. Sagittal imbalance was observed in 54% (45/83) of patients, and its risk factors were old age and a large mismatch between pelvic incidence and lumbar lordosis. The 1-year normalization rate was 73% after decompression surgery, and the median time to normalization was 1 to 3 months. Patients who did not experience SVA normalization exhibited low thoracic kyphosis (hazard ratio [HR], 1.04; 95% confidence interval [CI], 1.02-1.10) (pimbalance was observed in more than 50% of LSS patients, but this imbalance was correctable via simple decompression surgery in 70% of patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Focus Issue on surface plasmon photonics introduction

    DEFF Research Database (Denmark)

    Levy, Uriel; Berini, Pierre; Maier, Stefan A.

    2015-01-01

    The 7th International Conference on Surface Plasmon Photonics (SPP7) was held in Jerusalem, Israel from May 31st to June 5th, 2015. This independent series of biennial conferences is widely regarded as the premier series in the field, and the 7th edition maintained the tradition of excellence...

  12. The Influence of Natural Head Position on the Cervical Sagittal Alignment

    Directory of Open Access Journals (Sweden)

    Kuan Wang

    2017-01-01

    Full Text Available Introduction. This study investigated the relationship between the parameters related to the natural head position and cervical segmental angles and alignment of patients with neck pain. Material and Methods. The lateral radiographs of the cervical spine were collected from 103 patients and were used to retrospectively analyze the correlation between the natural head position, cervical local sagittal angles, and alignment. Sagittal measurements were as follows: cervical curvature classification, slope of McGregor’s line (McGS, local sagittal angles (C0–C2 angle, C2–C5 angle, C5–C7 angle, and C2–C7 angle, T1 slope, center of gravity of the head to sagittal vertical axis (CG–C7 SVA, and local sagittal alignment (C0–C2 SVA and C2–C7 SVA. Results. McGS was significantly correlated to C0–C2 angle (r=0.57, C0–C2 SVA (r=−0.53, C2–C7 SVA (r=−0.28, and CG–C7 SVA (r=−0.47. CG–C7 SVA was also significantly correlated to curvature type (r=0.27, C5–C7 angle (r=−0.37, and C2–C7 angle (r=−0.39. Conclusions. A backward shift with an extended head position may accompany a relatively normal curvature of the cervical spine. The effect of posture control in relieving abnormal mechanical state of the cervical spine needs to be further confirmed by biomechanical analysis.

  13. Photonics4All - Conduct photonics for investment in France and Slovakia

    OpenAIRE

    Gerente, Fiona; Chorvat, Dusan

    2017-01-01

    This project deliverable describes the organisation of different Photonics for Investment Events. “Photonics for investments” focuses on the support and investment in innovative ideas and photonics applications. The objective of this project task is to provide the opportunity for Photonics SMEs to present their products or services during pitch presentations to new customers and investors. The Photonics for Investment events have three main objectives. The first objective is to connect en...

  14. Sagittal alignment after single cervical disc arthroplasty.

    Science.gov (United States)

    Guérin, Patrick; Obeid, Ibrahim; Gille, Olivier; Bourghli, Anouar; Luc, Stéphane; Pointillart, Vincent; Vital, Jean-Marc

    2012-02-01

    Prospective study. To analyze the sagittal balance after single-level cervical disc replacement (CDR) and range of motion (ROM). To define clinical and radiologic parameters those have a significant correlation with segmental and overall cervical curvature after CDR. Clinical outcomes and ROM after CDR with Mobi-C (LDR, Troyes, France) prosthesis have been documented in few studies. No earlier report of this prosthesis has studied correlations between static and dynamic parameters or those between static parameters and clinical outcomes. Forty patients were evaluated. Clinical outcome was assessed using the Short Form-36 questionnaire, Neck Disability Index, and a Visual Analog Scale. Spineview software (Surgiview, Paris, France) was used to investigate sagittal balance parameters and ROM. The mean follow-up was 24.3 months (range: 12 to 36 mo). Clinical outcomes were satisfactory. There was a significant improvement of Short Form-36, Neck Disability Index, and Visual Analog Scale scores. Mean ROM was 8.3 degrees preoperatively and 11.0 degrees postoperatively (P=0.013). Mean preoperative C2C7 curvature was 12.8 and 16.0 degrees at last follow-up (P=0.001). Mean preoperative functional spinal unit (FSU) angle was 2.3 and 5.3 degrees postoperatively (P<0.0001). Mean postoperative shell angle was 5.5 degrees. There was a significant correlation between postoperative C2C7 alignment and preoperative C2C7 alignment, change of C2C7 alignment, preoperative and postoperative FSU angle, and prosthesis shell angle. There was also a significant correlation between postoperative FSU angle and preoperative C2C7 alignment, preoperative FSU angle, change of FSU angle, and prosthesis shell angle. Regression analysis showed that prosthesis shell angle and preoperative FSU angle contributed significantly to postoperative FSU angle. Moreover, preoperative C2C7 alignment, preoperative FSU angle, postoperative FSU angle, and prosthesis shell angle contributed significantly to

  15. Nonlinear Photonics 2014: introduction.

    Science.gov (United States)

    Akhmediev, N; Kartashov, Yaroslav

    2015-01-12

    International Conference "Nonlinear Photonics-2014" took place in Barcelona, Spain on July 27-31, 2014. It was a part of the "Advanced Photonics Congress" which is becoming a traditional notable event in the world of photonics. The current focus issue of Optics Express contains contributions from the participants of the Conference and the Congress. The articles in this focus issue by no means represent the total number of the congress contributions (around 400). However, it demonstrates wide range of topics covered at the event. The next conference of this series is to be held in 2016 in Australia, which is the home of many researchers working in the field of photonics in general and nonlinear photonics in particular.

  16. SAGITTAL DIAMETER OF FORAMEN MAGNUM IN NORMAL POPULATION: AN MRI STUDY

    OpenAIRE

    Lakshmi

    2015-01-01

    Lower position of cerebellar tonsils was frequently noticed in Western studies. In some of the studies, sagittal diameter of foramen magnum was found to be larger in cases of Chiari malformation. However, there are no Indian studies for comparison. Our study was proposed to determine the standard values for sagittal diameter of foramen magnum in various age groups and both sexes. This gives a guideline for further studies in pathological conditions like Craniovertebral Junctional ...

  17. 'Lumbar Degenerative Kyphosis' Is Not Byword for Degenerative Sagittal Imbalance: Time to Replace a Misconception.

    Science.gov (United States)

    Lee, Chang-Hyun; Chung, Chun Kee; Jang, Jee-Soo; Kim, Sung-Min; Chin, Dong-Kyu; Lee, Jung-Kil

    2017-03-01

    Lumbar degenerative kyphosis (LDK) is a subgroup of the flat-back syndrome and is most commonly caused by unique life styles, such as a prolonged crouched posture during agricultural work and performing activities of daily living on the floor. Unfortunately, LDK has been used as a byword for degenerative sagittal imbalance, and this sometimes causes confusion. The aim of this review was to evaluate the exact territory of LDK, and to introduce another appropriate term for degenerative sagittal deformity. Unlike what its name suggests, LDK does not only include sagittal balance disorder of the lumbar spine and kyphosis, but also sagittal balance disorder of the whole spine and little lordosis of the lumbar spine. Moreover, this disease is closely related to the occupation of female farmers and an outdated Asian life style. These reasons necessitate a change in the nomenclature of this disorder to prevent misunderstanding. We suggest the name "primary degenerative sagittal imbalance" (PDSI), which encompasses degenerative sagittal misalignments of unknown origin in the whole spine in older-age patients, and is associated with back muscle wasting. LDK may be regarded as a subgroup of PDSI related to an occupation in agriculture. Conservative treatments such as exercise and physiotherapy are recommended as first-line treatments for patients with PDSI, and surgical treatment is considered only if conservative treatments failed. The measurement of spinopelvic parameters for sagittal balance is important prior to deformity corrective surgery. LDK can be considered a subtype of PDSI that is more likely to occur in female farmers, and hence the use of LDK as a global term for all degenerative sagittal imbalance disorders is better avoided. To avoid confusion, we recommend PDSI as a newer, more accurate diagnostic term instead of LDK.

  18. Deterministically swapping frequency-bin entanglement from photon-photon to atom-photon hybrid systems

    Science.gov (United States)

    Ou, Bao-Quan; Liu, Chang; Sun, Yuan; Chen, Ping-Xing

    2018-02-01

    Inspired by the recent developments of the research on the atom-photon quantum interface and energy-time entanglement between single-photon pulses, we are motivated to study the deterministic protocol for the frequency-bin entanglement of the atom-photon hybrid system, which is analogous to the frequency-bin entanglement between single-photon pulses. We show that such entanglement arises naturally in considering the interaction between a frequency-bin entangled single-photon pulse pair and a single atom coupled to an optical cavity, via straightforward atom-photon phase gate operations. Its anticipated properties and preliminary examples of its potential application in quantum networking are also demonstrated. Moreover, we construct a specific quantum entanglement witness tool to detect such extended frequency-bin entanglement from a reasonably general set of separable states, and prove its capability theoretically. We focus on the energy-time considerations throughout the analysis.

  19. Measuring Fractional Anisotropy of the Corpus Callosum Using Diffusion Tensor Imaging: Mid-Sagittal versus Axial Imaging Planes

    International Nuclear Information System (INIS)

    Kim, Eung Yeop; Park, Hae Jeong; Kim, Dong Hyun; Lee, Seung Koo; Kim, Jin Na

    2008-01-01

    Many diffusion tensor imaging (DTI) studies of the corpus callosum (CC) have been performed with a relatively thick slice thickness in the axial plane, which may result in underestimating the fractional anisotropy (FA) of the CC due to a partial volume effect. We hypothesized that the FA of the CC can be more accurately measured by using mid-sagittal DTI. We compared the FA values of the CC between the axial and mid-sagittal DTI. Fourteen healthy volunteers underwent MRI at 3.0 T. DTI was performed in both the mid-sagittal and axial planes. One 5-mm mid-sagittal image and twenty-five 2-mm axial images were obtained for the CC. The five regions of interest (ROIs) that included the prefrontal (I), premotor and supplementary motor (II), motor (III), sensory (IV) and parietal, temporal and occipital regions (V) were drawn along the border of the CC on each sagittal FA map. The FA values obtained from each region were compared between the two sagittal maps. The FA values of all the regions, except for region V, were significantly increased on the mid-sagittal imaging. The FA values in region IV were significantly underestimated on the mid-sagittal image from the axial imaging, compared with those in the regions I and V (p = 0.037 and p = 0.001, respectively). The FA values of the CC were significantly higher on the midsagittal DTI than those on the axial DTI in regions I-IV, and particularly in the region IV. Mid-sagittal DTI may provide more accurate FA values of the CC than can the axial DTI, and mid-sagittal DTI may be more desirable for studies that compare between patients and healthy subjects

  20. Sagittal Alignment As a Predictor of Clinical Adjacent Segment Pathology requiring Surgery after Anterior Cervical Arthrodesis

    Science.gov (United States)

    Park, Moon Soo; Kelly, Michael P.; Lee, Dong-Ho; Min, Woo-Kie; Rahman, Ra’Kerry K.; Riew, K. Daniel

    2014-01-01

    BACKGROUND CONTEXT Postoperative malalignment of the cervical spine may alter cervical spine mechanics, and put patients at risk for clinical adjacent segment pathology requiring surgery. PURPOSE To investigate whether a relationship exists between cervical spine sagittal alignment and clinical adjacent segment pathology requiring surgery (CASP-S) following anterior cervical fusion (ACF). STUDY DESIGN Retrospective matched study. PATIENT SAMPLE One hundred twenty two patients undergoing ACF from 1996 to 2008 were identified, with a minimum of 2 year follow-up. OUTCOME MEASURES Radiographs were reviewed to measure the sagittal alignment using C2 and C7 sagittal plumb lines, distance from the fusion mass plumb line to the C2 and C7 plumb lines, the alignment of the fusion mass, caudally adjacent disc angle, the sagittal slope angle of the superior endplate of the vertebra caudally adjacent to the fusion mass, T1 sagittal angle, overall cervical sagittal alignment, and curve patterns by Katsuura classification. METHODS One hundred twenty two patients undergoing ACF from 1996 to 2008 were identified, with a minimum of 1 year follow-up. Patients were divided into groups according to the development of CASP requiring surgery (Control / CASP-S) and by number/location of levels fused. Radiographs were reviewed to measure the sagittal alignment using C2 and C7 sagittal plumb lines, distance from the fusion mass plumb line to the C2 and C7 plumb lines, the alignment of the fusion mass, caudally adjacent disc angle, the sagittal slope angle of the superior endplate of the vertebra caudally adjacent to the fusion mass, T1 sagittal angle, overall cervical sagittal alignment, and curve patterns by Katsuura classification. Appropriate statistical tests were performed to calculate relationships between the variables and the development of CASP-S. No funds were received in support of this work. No benefits in any form have been or will be received from a commercial party related

  1. Comparison of accuracy of uncorrected and corrected sagittal tomography in detection of mandibular condyle erosions: An exvivo study

    Directory of Open Access Journals (Sweden)

    Asieh Zamani Naser

    2010-01-01

    Full Text Available Background: Radiographic examination of TMJ is indicated when there are clinical signs of pathological conditions, mainly bone changes that may influence the diagnosis and treatment planning. The purpose of this study was to evaluate and to compare the validity and diagnostic accuracy of uncorrected and corrected sagittal tomographic images in the detection of simulated mandibular condyle erosions. Methods : Simulated lesions were created in 10 dry mandibles using a dental round bur. Using uncorrected and corrected sagittal tomography techniques, mandibular condyles were imaged by a Cranex Tome X-ray unit before and after creating the lesions. The uncorrected and corrected tomography images were examined by two independent observers for absence or presence of a lesion. The accuracy for detecting mandibular condyle lesions was expressed as sensitivity, specificity, and validity values. Differences between the two radiographic modalities were tested by Wilcoxon for paired data tests. Inter-observer agreement was determined by Cohen′s Kappa. Results: The sensitivity, specificity and validity were 45%, 85% and 30% in uncorrected sagittal tomographic images, respectively, and 70%, 92.5% and 60% in corrected sagittal tomographic images, respectively. There was a significant statistical difference between the accuracy of uncorrected and corrected sagittal tomography in detection of mandibular condyle erosions (P = 0.016. The inter-observer agreement was slight for uncorrected sagittal tomography and moderate for corrected sagittal tomography. Conclusion: The accuracy of corrected sagittal tomography is significantly higher than that of uncorrected sagittal tomography. Therefore, corrected sagittal tomography seems to be a better modality in detection of mandibular condyle erosions.

  2. Direct CT scanning of the lesser pelvis - frontal vs sagittal plane

    International Nuclear Information System (INIS)

    Khadzhigeorgiev, G.; Lichev, A.

    1994-01-01

    Whenever axial scanning alone is used, the anatomical patterns of the true pelvis and the organs contained in it, particularly in women, give rise to diagnostic difficulties during CT assessment of neoplasms originating from these organs. The high demands on precision characterization of the pathological changes in the pelvis minor organs necessitate the obtaining of reliable density and size measurement data, not merely from the axial plane, but from the frontal and sagittal ones as well. The deficient information afforded by secondary reconstruction of the pelvis mind images requires an mandatory evaluation of the potentialities of direct frontal and direct sagittal scanning of the pelvis minor using standard CT equipment. Information yielded by images from direct frontal and direct sagittal pelvis minor scanning as well as diagnostic problems where application of this type of scanning is indicated operational difficulties and their overcoming, are among the issues discussed. 8 figs., 7 refs

  3. A comparison of cephalometric analyses for assessing sagittal jaw relationship

    International Nuclear Information System (INIS)

    Erum, G.; Fida, M.

    2008-01-01

    To compare the seven methods of cephalometric analysis for assessing sagittal jaw relationship and to determine the level of agreement between them. Seven methods, describing anteroposterior jaw relationships (A-B plane, ANB, Wits, AXB, AF-BF, FABA and Beta angle) were measured on the lateral cephalographs of 85 patients. Correlation analysis, using Cramer's V-test, was performed to determine the possible agreement between the pair of analyses. The mean age of the sample, comprising 35 males and 50 females was 15 years and 3 months. Statistically significant relationships were found among seven sagittal parameters with p-value <0.001. Very strong correlation was found between AXB and AF-BF distance (r=0.924); and weak correlation between ANB and Beta angle (r=0.377). Wits appraisal showed the greatest coefficient of variability. Despite varying strengths of association, statistically significant correlations were found among seven methods for assessing sagittal jaw relationship. FABA and A-B plane may be used to predict the skeletal class in addition to the established ANB angle. (author)

  4. PARAMETERS FOR THE EVALUATION OF CERVICAL SAGITTAL BALANCE IN IDIOPATHIC SCOLIOSIS

    Directory of Open Access Journals (Sweden)

    MAURICIO COELHO LIMA

    Full Text Available ABSTRACT Objective: There are no values defined as standard in the literature for the parameters of assessment of cervical sagittal balance in patients with idiopathic scoliosis. This study describes the sagittal cervical parameters in patients with idiopathic scoliosis. Methods: Study carried out in a tertiary public hospital in patients with adolescent idiopathic scoliosis, through the evaluation of panoramic radiographs in lateral view. The Cobb method was used to evaluate cervical lordosis from C2 to C7, distance from the center of gravity (COG of the skull to C7, measurement of T1 slope, thoracic inlet angle (TIA, neck tilt, and plumb line from C7 to S1 (SVA C7-S1. A statistical analysis was performed, to demonstrate the relationship between the alignment of the thoracic spine in the sagittal plane and the cervical sagittal balance of patients with scoliosis. Results: Thirty-four patients were female (69.4% and 15 male (30.6%. The mean values for COG-C7 were 0.71 mm (median 0.8 mm/standard deviation [SD]= 0.51 mm. For Cobb C2-C7, the mean was -11.7° (median -10°/SD= 20.4°. The mean slope of T1 was 23.5° (median 25°/SD= 9.5°. The mean cervical version was 58.8° (median 60°/DP= 15.4°. The mean TIA was 81.8° (median 85°/SD= 16.7°. The mean plumb line C7-S1 was -0.28 (-0.3/SD= 1.0. Conclusion: The analysis of the results showed that the mean values for the cervical lordosis are lower than the values described as normal in the literature, suggesting a loss of sagittal cervical balance in these patients.

  5. Sagittal plane analysis of the spine and pelvis in degenerative lumbar scoliosis.

    Science.gov (United States)

    Han, Fei; Weishi, Li; Zhuoran, Sun; Qingwei, Ma; Zhongqiang, Chen

    2017-01-01

    Previous studies have reported the normative values of pelvic sagittal parameters, but no study has analyzed the sagittal spino-pelvic alignment in degenerative lumbar scoliosis (DLS) and its role in the pathogenesis. Retrospective analysis was applied to 104 patients with DLS, together with 100 cases of asymptomatic young adults as a control group and another control group consisting of 145 cases with cervical spondylosis. The coronal and sagittal parameters were measured on the anteroposterior and lateral radiograph of the whole spine in the DLS group as well as in the two control groups. Statistical analysis showed that the DLS group had a higher pelvic incidence (PI) value (50.5° ± 10.2°), than the normal control group (with PI 47.2° ± 8.8°) and the cervical spondylosis group (46.9° ± 9.1°). In DLS group, there were 38 cases (36.5%) complicated with degenerative lumbar spondylolisthesis, who had higher PI values than patients without it. Besides, the lumbar lordosis (LL) and sacral slope (SS) of DLS group were lower; the scoliosis Cobb's angle was correlated with pelvic tilt (PT); thoracic kyphosis was correlated with LL, SS, and PT; and LL was correlated with other sagittal parameters. Patients with DLS may have a higher PI, which may impact the pathogenesis of DLS. A high PI value is probably associated with the high prevalence of degenerative lumbar spondylolisthesis among DLS patients. In DLS patients, the lumbar spine maintains the ability of regulating the sagittal balance, and the regulation depends more on thoracic curve.

  6. Influence of implant rod curvature on sagittal correction of scoliosis deformity

    DEFF Research Database (Denmark)

    Salmingo, Remel A.; Tadano, Shigeru; Abe, Yuichiro

    2014-01-01

    of the implant rod’s angle of curvature during surgery and establish its influence on sagittal correction of scoliosis deformity. STUDY DESIGN: A retrospective analysis of the preoperative and postoperative implant rod geometry and angle of curvature was conducted. PATIENT SAMPLE: Twenty adolescent idiopathic......BACKGROUND CONTEXT: Deformation of in vivo–implanted rods could alter the scoliosis sagittal correction. To our knowledge, no previous authors have investigated the influence of implanted-rod deformation on the sagittal deformity correction during scoliosis surgery. PURPOSE: To analyze the changes...... scoliosis patients underwent surgery. Average age at the time of operation was 14 years. OUTCOME MEASURES: The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. METHODS: Two implant rods were attached to the concave and convex side...

  7. The longitudinal sagittal growth changes of maxilla and mandible according to quantitative cervical vertebral maturation.

    Science.gov (United States)

    Chen, Lili; Lin, Jiuxiang; Xu, Tianmin; Long, Xiaosi

    2009-04-01

    To investigate the longitudinal sagittal growth changes of maxilla and mandible according to the quantitative cervical vertebral maturation (QCVM) for adolescents with normal occlusion, mixed longitudinal data were used. The samples included 87 adolescents aged from 8 to 18 y old with normal occlusion (32 males, 55 females) selected from 901 candidates. Sequential lateral cephalograms and hand-wrist films were taken once a year, lasting for 6 y. The longitudinal sagittal growth changes of maxilla and mandible according to QCVM were measured. There were some significant differences between maxilla and mandible according to QCVM. The sagittal growth change of maxilla showed a trend towards high velocity-->decelerating velocity-->completing velocity from QCVM stage I to stage IV. The sagittal growth change of mandible showed a trend towards accelerating velocity-->high velocity-->decelerating velocity-->completing velocity from QCVM stage I to stage IV. With sagittal relationship, growth magnitude was almost the same between maxilla and mandible at QCVM stage I. At stage II the growth of mandible exceeded that of maxilla and growth in mandible continued at stages III and IV, while the maxilla ceased to grow. Growth magnitude was greater and the growth duration was longer with male mandible. It is concluded that the longitudinal sagittal growth changes of maxilla and mandible on the basis of QCVM is of value in the orthodontic practice.

  8. ‘Lumbar Degenerative Kyphosis’ Is Not Byword for Degenerative Sagittal Imbalance: Time to Replace a Misconception

    Science.gov (United States)

    Lee, Chang-Hyun; Chung, Chun Kee; Jang, Jee-Soo; Kim, Sung-Min; Chin, Dong-Kyu; Lee, Jung-Kil

    2017-01-01

    Lumbar degenerative kyphosis (LDK) is a subgroup of the flat-back syndrome and is most commonly caused by unique life styles, such as a prolonged crouched posture during agricultural work and performing activities of daily living on the floor. Unfortunately, LDK has been used as a byword for degenerative sagittal imbalance, and this sometimes causes confusion. The aim of this review was to evaluate the exact territory of LDK, and to introduce another appropriate term for degenerative sagittal deformity. Unlike what its name suggests, LDK does not only include sagittal balance disorder of the lumbar spine and kyphosis, but also sagittal balance disorder of the whole spine and little lordosis of the lumbar spine. Moreover, this disease is closely related to the occupation of female farmers and an outdated Asian life style. These reasons necessitate a change in the nomenclature of this disorder to prevent misunderstanding. We suggest the name “primary degenerative sagittal imbalance” (PDSI), which encompasses degenerative sagittal misalignments of unknown origin in the whole spine in older-age patients, and is associated with back muscle wasting. LDK may be regarded as a subgroup of PDSI related to an occupation in agriculture. Conservative treatments such as exercise and physiotherapy are recommended as first-line treatments for patients with PDSI, and surgical treatment is considered only if conservative treatments failed. The measurement of spinopelvic parameters for sagittal balance is important prior to deformity corrective surgery. LDK can be considered a subtype of PDSI that is more likely to occur in female farmers, and hence the use of LDK as a global term for all degenerative sagittal imbalance disorders is better avoided. To avoid confusion, we recommend PDSI as a newer, more accurate diagnostic term instead of LDK. PMID:28264231

  9. On-chip steering of entangled photons in nonlinear photonic crystals.

    Science.gov (United States)

    Leng, H Y; Yu, X Q; Gong, Y X; Xu, P; Xie, Z D; Jin, H; Zhang, C; Zhu, S N

    2011-08-16

    One promising technique for working toward practical photonic quantum technologies is to implement multiple operations on a monolithic chip, thereby improving stability, scalability and miniaturization. The on-chip spatial control of entangled photons will certainly benefit numerous applications, including quantum imaging, quantum lithography, quantum metrology and quantum computation. However, external optical elements are usually required to spatially control the entangled photons. Here we present the first experimental demonstration of on-chip spatial control of entangled photons, based on a domain-engineered nonlinear photonic crystal. We manipulate the entangled photons using the inherent properties of the crystal during the parametric downconversion, demonstrating two-photon focusing and beam-splitting from a periodically poled lithium tantalate crystal with a parabolic phase profile. These experimental results indicate that versatile and precise spatial control of entangled photons is achievable. Because they may be operated independent of any bulk optical elements, domain-engineered nonlinear photonic crystals may prove to be a valuable ingredient in on-chip integrated quantum optics.

  10. The angle of inclination of the native ACL in the coronal and sagittal planes.

    Science.gov (United States)

    Reid, Jonathan C; Yonke, Bret; Tompkins, Marc

    2017-04-01

    The purpose of this cross-sectional study was to evaluate the angle of inclination of the native anterior cruciate ligament (ACL) in both the sagittal and coronal planes and to evaluate these findings based on sex, height, BMI, and skeletal maturity. Inclusion criteria for the study included patients undergoing routine magnetic resonance imaging (MRI) of the knee at a single outpatient orthopedic center who had an intact ACL on MRI. Measurements of the angle of inclination were made on MRIs in both the sagittal and coronal planes. Patients were compared based on sex, height, BMI, and skeletal maturity. One-hundred and eighty-eight patients were included (36 skeletally immature/152 skeletally mature; 98 male/90 female). The overall angle of inclination was 74.3° ± 4.8° in the coronal plane and 46.9° ± 4.9° in the sagittal plane. Skeletally immature patients (coronal: 71.8° ± 6.1°; sagittal: 44.7° ± 5.5°) were significantly different in both coronal and sagittal planes (P = 0.04 and 0.01, respectively) from skeletally mature patients (coronal: 75.3° ± 4.7°; sagittal: 47.4° ± 4.7°). There were no differences based on sex, height, or BMI. There are differences between the angle of inclination findings in this study and other studies, which could be due to MRI and measurement techniques. Clinically, skeletal maturity may be important to account for when using the ACL angle of inclination to evaluate anatomic ACL reconstruction. Prognostic retrospective study, Level of evidence III.

  11. Robust Adaptive Photon Tracing using Photon Path Visibility

    DEFF Research Database (Denmark)

    Hachisuka, Toshiya; Jensen, Henrik Wann

    2011-01-01

    We present a new adaptive photon tracing algorithm which can handle illumination settings that are considered difficult for photon tracing approaches such as outdoor scenes, close-ups of a small part of an illuminated region, and illumination coming through a small gap. The key contribution in our...... algorithm is the use of visibility of photon path as the importance function which ensures that our sampling algorithm focuses on paths that are visible from the given viewpoint. Our sampling algorithm builds on two recent developments in Markov chain Monte Carlo methods: adaptive Markov chain sampling...... and replica exchange. Using these techniques, each photon path is adaptively mutated and it explores the sampling space efficiently without being stuck at a local peak of the importance function. We have implemented this sampling approach in the progressive photon mapping algorithm which provides visibility...

  12. Investigation of reconstruction conditions in sagittal-plane multiplanar reconstruction of the temporal bone

    International Nuclear Information System (INIS)

    Suzuki, Miyako; Yoshikawa, Hiroshi; Hosokawa, Akira; Ichikawa, Ginichiro; Kobayashi, Kenichi; Ando, Ichiro

    2002-01-01

    In recent years, it has become possible to quickly obtain a large amount of 3D data with high continuity by helical CT scanning, in which the body is scanned continuously in a helical fashion. MPR (multiplanar reconstruction) can be performed using this data to generate images in arbitrary sectional planes, making it possible to obtain sagittal-plane images of the highest quality, which is useful for surgical planning. However, the procedures involved are rather complicated. Therefore, this study was conducted to investigate conditions for standardization of sagittal-plane MPR examinations performed using Xvigor CT scanners and Xtension. The results showed that a slice interval of 1 mm, no imaging filter, a zooming factor of 1.5, a window level of 350, and a window width of 3500 are the optimal imaging conditions. The stapes can be visualized in 70% of cases with sagittal-plane MPR based on axial images, and can be recognized at surgery in 75% or more of cases. Images of consistent quality can be obtained by standardizing the conditions for sagittal-plane MPR, which should prove advantageous in the clinical setting. (author)

  13. Signs of patellar chondromalacia on sagittal T2-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    De Smet, A.A.; Monu, J.U.; Fisher, D.R.; Keene, J.S.; Graf, B.K.

    1992-01-01

    We incidentally noted distinctive high signal defects or fissures in the patellar articular cartilage on sagittal T2-weighted magnetic resonance (MR) images in 4 patients. At subsequent arthroscopy all 4 patients were found to have patellar chondromalacia. To determine the reliabilty of these signs, we retrospectively evaluated, in a blinded manner, sagittal T2-weighted MR images of the knee in 75 patients who were undergoing arthroscopic assessment of their patellar articular cartilage. We indentified high signal defects of fissures in the patellar cartilage of 5 patients. Patellar chondromalacia was noted at arthroscopy in all 5 patients. Arthroscopy demonstrated patellar chondromalacia in an additional 21 patients with normal MR images. We conclude that high signal defects or fissures on sagittal T2-weighted images are usefull signs of patellar chondromalacia. This single imaging sequence will, however, detect only a small number of the cartilage lesions that may be present. (orig.)

  14. Signs of patellar chondromalacia on sagittal T2-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    De Smet, A.A.; Monu, J.U.; Fisher, D.R. (Univ. of Wisconsin Hospital and Clinics, Dept. of Radiology, Madison, WI (United States)); Keene, J.S.; Graf, B.K. (Univ. of Wisconsin Hospital and Clinics, Div. of Orthopedic Surgery, Madison, WI (United States))

    1992-02-01

    We incidentally noted distinctive high signal defects or fissures in the patellar articular cartilage on sagittal T2-weighted magnetic resonance (MR) images in 4 patients. At subsequent arthroscopy all 4 patients were found to have patellar chondromalacia. To determine the reliabilty of these signs, we retrospectively evaluated, in a blinded manner, sagittal T2-weighted MR images of the knee in 75 patients who were undergoing arthroscopic assessment of their patellar articular cartilage. We indentified high signal defects of fissures in the patellar cartilage of 5 patients. Patellar chondromalacia was noted at arthroscopy in all 5 patients. Arthroscopy demonstrated patellar chondromalacia in an additional 21 patients with normal MR images. We conclude that high signal defects or fissures on sagittal T2-weighted images are usefull signs of patellar chondromalacia. This single imaging sequence will, however, detect only a small number of the cartilage lesions that may be present. (orig.).

  15. Silicon light-emitting diodes and lasers photon breeding devices using dressed photons

    CERN Document Server

    Ohtsu, Motoichi

    2016-01-01

    This book focuses on a novel phenomenon named photon breeding. It is applied to realizing light-emitting diodes and lasers made of indirect-transition-type silicon bulk crystals in which the light-emission principle is based on dressed photons. After presenting physical pictures of dressed photons and dressed-photon phonons, the principle of light emission by using dressed-photon phonons is reviewed. A novel phenomenon named photon breeding is also reviewed. Next, the fabrication and operation of light emitting diodes and lasers are described The role of coherent phonons in these devices is discussed. Finally, light-emitting diodes using other relevant crystals are described and other relevant devices are also reviewed.

  16. Noninvasive Optoelectronic Assessment of Induced Sagittal Imbalance Using the Vicon System.

    Science.gov (United States)

    Ould-Slimane, Mourad; Latrobe, Charles; Michelin, Paul; Chastan, Nathalie; Dujardin, Franck; Roussignol, Xavier; Gauthé, Rémi

    2017-06-01

    Spinal diseases often induce gait disorders with multifactorial origins such as lumbar pain, radicular pain, neurologic complications, or spinal deformities. However, radiography does not permit an analysis of spinal dynamics; therefore, sagittal balance dynamics during gait remain largely unexplored. This prospective and controlled pilot study assessed the Vicon system for detecting sagittal spinopelvic imbalance, to determine the correlations between optoelectronic and radiographic parameters. Reversible anterior sagittal imbalance was induced in 24 healthy men using a thoracolumbar corset. Radiographic, optoelectronic, and comparative analyses were conducted. Corset wearing induced significant variations in radiographic parameters indicative of imbalance; the mean C7-tilt and d/D ratio increased by 15° ± 7.4° and 359%, respectively, whereas the mean spinosacral angle decreased by 16.8° ± 8° (all P imbalance; the mean spinal angle increased by 15.4° ± 5.6° (P imbalance detected using the Vicon system. Optoelectronic C7'S1' correlated with radiographic C7-tilt and d/D ratio. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. A previously unreported variant of the synostotic sagittal suture: Case report and review of salient literature

    Directory of Open Access Journals (Sweden)

    Madison Budinich

    2016-12-01

    Full Text Available Introduction: Sagittal synostosis is a rare congenital disease caused by the premature fusion of the sagittal suture. Craniosynostosis occurs for a variety of reasons, different for every case, and often the etiology is unclear but the anomaly can frequently be seen as part of Crouzon's or Apert's syndromes. Herein, we discuss a rare case of craniosynostosis where the patient presented with a, to our knowledge, a previously undescribed variant of sagittal synostosis. Case report: A 3-month-old female infant presented to a craniofacial clinic for a consultation regarding an abnormal head shape. Images of the skull were performed, demonstrating that the patient had craniosynostosis. The patient displayed no other significant symptoms besides abnormalities in head shape. The sagittal suture was found to extend into the occipital bone where it was synostotic. Conclusion: To our knowledge, a synostotic sagittal suture has not been reported that extended posteriorly it involve the occipital bone. Those who interpret imaging or operate on this part of the skull should consider such a variation. Keywords: Anatomy, Craniosynostosis, Skull, Malformation, Pediatrics

  18. Benefits of sagittal-oblique MRI reconstruction of anterior cruciate ligament of the knee

    International Nuclear Information System (INIS)

    Nenezić, D.

    2015-01-01

    Full text: MRI examination of the anterior cruciate ligament (ACL) of the knee gives valuable information for conventional, physiatrist and/or arthroscopic microinvasiv treatment. three planar MRI examination and 3D reconstructions are highly precise in the analysis of the intra and periarticular structures, with exceptions of anterior cruciate ligament. Direct contact with the roof of the intercondilar fossa (in the full extension during the examination) and its specific orientation makes visualization of ACL diagnostically problematic. In a one year period precise protocol for MRI visualization of ACL was tested and applied as “Sagittal Oblique MRI Reconstruction”. In short, it has been Angled biplanar reconstruction in the parasagital and paratransversal planes (patientrelated and arbitrary selected in full extension), on T2, 2mm slice and 0,2 mm gap. 153 MRI examinations of the patients with lesions of the ACL were included in the study in the Clinical Center of Montenegro during 2005 year. Beside standard Knee MRI protocol all patients had the Sagittal Oblique MRI reconstruction of ACL and the Flexion MRI examination, to compare with. The Sagittal Oblique MRI reconstruction of ACL it is adapted to the concrete morphology of the patients ACL and it does not depend of the volume of the examined knee. In comparison with the Standard Knee MRI protocol and with the Flexion MRI examination, the Sagittal Oblique MRI reconstruction of ACL takes less time to perform, and the ligament is shown in fool length at three to five slices, which is more than with the both compared protocols. Sagittal Oblique MRI Reconstruction of ACL is therefore patient dependable, orientated in shape of concrete ligament of the patient’s knee. In combination with age, occupation, physical activity and level of patients while to contribute in healing process, the Sagittal Oblique MRI reconstruction of ACL contribute to scholastic approach, as highest benefit to patients with

  19. INFLUENCE OF THE SAGITTAL BALANCE ON THE CLINICAL OUTCOME IN SPINAL FUSION

    Directory of Open Access Journals (Sweden)

    Marcela Almeida Campos Coutinho

    2016-03-01

    Full Text Available ABSTRACT Objective: Evaluates which radiographic parameters of the sagittal and spinopelvic balance influence the clinical and functional outcomes of a sample of patients undergoing spinal fusion. Methods: We studied 32 patients who underwent spinal fusion. Radiographs of the total spine were obtained from all patients. The clinical and functional parameters studied were analysis of pain by visual analogic scale (VAS and Oswestry and SRS-30 questionnaires. We analyzed the correlation between the clinical and functional parameters and radiographic parameters of the sagittal and spinopelvic balance. Results: There was no significant correlation between parameters pelvic incidence (PI, pelvic tilt (PT, lumbar lordosis (LL and difference between PI and LL (PI-LL and clinical parameters (p > 0.05 and r <0.2. Significant correlation were identified only between Sagittal Vertical Axis (SVA and Satisfaction with Treatment domain of SRS-30 (r = 0.402 e p = 0.023 and between thoracic kyphosis (TK and the total SRS-30 (r = 0.419 and p = 0.017. Conclusions: According to the study results, it was not possible to precisely characterize the role of the parameters of the sagittal and spinopelvic balance in the post-operative analysis of the clinical outcome of spinal fusion. There was a significant correlation only between SVA and the Satisfaction with Treatment domain of SRS-30 and between TK and total SRS-30.

  20. Tracking errors in tractography of the gastrocnemius muscle. A comparison between the transverse and sagittal planes

    International Nuclear Information System (INIS)

    Aoki, Takako; Tohdoh, Yukihiro; Tawara, Noriyuki; Okuwaki, Toru; Horiuchi, Akira; Itagaki, Takuma; Niitsu, Mamoru

    2010-01-01

    In scans taken in conventional direction, tracking errors may occur when using a streamline-based algorithm for the tractography of the gastrocnemius muscle. To solve errors in tracking, we applied tractography to the musculotendinous junction and performed fiber tracking on the gastrocnemius muscle of 10 healthy subjects with their written informed consent. We employed a spin-echo diffusion tensor imaging (SE-DTI) sequence with 6-direction diffusion gradient sensitization and acquired DTI images at 1.5 tesla using a body array coil with parallel imaging. We compared tractography obtained in the transverse and sagittal planes using anatomical reference and found that the gastrocnemius muscle and musculotendinous junction were significantly better visualized on sagittal scans and in 3 regions of interest. We utilized Mann-Whitney U-test to determine significant differences between rates of concordance (P 2 value of skeletal muscle is around 50 ms, and TE should be as short as possible. A streamline-based algorithm is based on the continuity of a vector. It is easy to take running of the muscle fiber in sagittal scan. Therefore, tracking error is hard to occur. In conclusion, sagittal scanning may be one way to eliminate tracking errors in the tractography of the gastrocnemius muscle. Tracking errors were smaller with sagittal scans than transverse scans, and sagittal scans allow better fiber tracking. (author)

  1. Measurement and Finite Element Model Validation of Immature Porcine Brain-Skull Displacement during Rapid Sagittal Head Rotations.

    Science.gov (United States)

    Pasquesi, Stephanie A; Margulies, Susan S

    2018-01-01

    Computational models are valuable tools for studying tissue-level mechanisms of traumatic brain injury, but to produce more accurate estimates of tissue deformation, these models must be validated against experimental data. In this study, we present in situ measurements of brain-skull displacement in the neonatal piglet head ( n  = 3) at the sagittal midline during six rapid non-impact rotations (two rotations per specimen) with peak angular velocities averaging 51.7 ± 1.4 rad/s. Marks on the sagittally cut brain and skull/rigid potting surfaces were tracked, and peak values of relative brain-skull displacement were extracted and found to be significantly less than values extracted from a previous axial plane model. In a finite element model of the sagittally transected neonatal porcine head, the brain-skull boundary condition was matched to the measured physical experiment data. Despite smaller sagittal plane displacements at the brain-skull boundary, the corresponding finite element boundary condition optimized for sagittal plane rotations is far less stiff than its axial counterpart, likely due to the prominent role of the boundary geometry in restricting interface movement. Finally, bridging veins were included in the finite element model. Varying the bridging vein mechanical behavior over a previously reported range had no influence on the brain-skull boundary displacements. This direction-specific sagittal plane boundary condition can be employed in finite element models of rapid sagittal head rotations.

  2. Measurement and Finite Element Model Validation of Immature Porcine Brain–Skull Displacement during Rapid Sagittal Head Rotations

    Science.gov (United States)

    Pasquesi, Stephanie A.; Margulies, Susan S.

    2018-01-01

    Computational models are valuable tools for studying tissue-level mechanisms of traumatic brain injury, but to produce more accurate estimates of tissue deformation, these models must be validated against experimental data. In this study, we present in situ measurements of brain–skull displacement in the neonatal piglet head (n = 3) at the sagittal midline during six rapid non-impact rotations (two rotations per specimen) with peak angular velocities averaging 51.7 ± 1.4 rad/s. Marks on the sagittally cut brain and skull/rigid potting surfaces were tracked, and peak values of relative brain–skull displacement were extracted and found to be significantly less than values extracted from a previous axial plane model. In a finite element model of the sagittally transected neonatal porcine head, the brain–skull boundary condition was matched to the measured physical experiment data. Despite smaller sagittal plane displacements at the brain–skull boundary, the corresponding finite element boundary condition optimized for sagittal plane rotations is far less stiff than its axial counterpart, likely due to the prominent role of the boundary geometry in restricting interface movement. Finally, bridging veins were included in the finite element model. Varying the bridging vein mechanical behavior over a previously reported range had no influence on the brain–skull boundary displacements. This direction-specific sagittal plane boundary condition can be employed in finite element models of rapid sagittal head rotations. PMID:29515995

  3. The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

    Science.gov (United States)

    Han, Hyuk-Soo; Kang, Seung-Baik; Jo, Chris H; Kim, Sun-Hong; Lee, Jung-Ha

    2010-10-01

    Experimental and clinical studies on the accuracy of the intramedullary alignment method have produced different results, and few have addressed accuracy in the sagittal plane. Reported deviations are not only attributable to the alignment method but also to radiological errors. The purpose of this study was to evaluate the accuracy of the intramedullary alignment method in the sagittal plane using computed tomography (CT) and 3-dimensional imaging software. Thirty-one TKAs were performed using an intramedullary alignment method involving the insertion of a long 8-mm diameter rod into the medullary canal to the distal metaphysis of the tibia. All alignment instruments were set to achieve an ideal varus/valgus angle of 0° in the coronal plane and a tibial slope of 0° in the sagittal plane. The accuracy of the intramedullary alignment system was assessed by measuring the coronal tibial component angle and sagittal tibial slope angles, i.e., angles between the tibial anatomical axis and the tangent to the medial and lateral tibial plateau or the cut-surface. The mean coronal tibial component angle was 88.5° ± 1.2° and the mean tibial component slope in the sagittal plane was 1.6° ± 1.2° without anterior slope. Our intramedullary tibial alignment method, which involves passing an 8-mm diameter long rod through the tibial shaft isthmus, showed good accuracy (less than 3 degrees of variation and no anterior slope) in the sagittal plane in neutral or varus knees.

  4. Conjoined lumbosacral nerve roots compromised by disk herniation: sagittal shoulder sign for the preoperative diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Chang Ho [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Korea University College of Medicine, Department of Radiology, Anam Hospital, Seoul (Korea); Shin, Myung Jin; Kim, Sung Moon; Lee, Sang Hoon; Kim, Hee Kyung; Ryu, Jeong Ah [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Lee, Choon-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Orthopedic Surgery, Seoul (Korea); Kim, Sam Soo [Kangwon National University College of Medicine, Department of Radiology, Kangwon (Korea)

    2008-03-15

    The objective was to determine the importance of the ''sagittal shoulder sign'' on magnetic resonance (MR) images for the diagnosis of conjoined lumbosacral nerve roots (CLNR) that are compromised by herniated disks. Magnetic resonance images of 11 patients (6 men and 5 women; age range, 25-71 years; average age, 48.7 years) with surgically proven CLNR, which was compromised by herniated disks, were retrospectively evaluated by two musculoskeletal radiologists. MR images were evaluated for the presence or absence of the sagittal shoulder sign - a vertical structure connecting two consecutive nerve roots and overlying disk on the sagittal MR images. The radiologists noted the type of accompanying disk herniation and bony spinal canal changes, as well as other characteristic MR features of CLNR, the common passage of two consecutive nerve roots through the neural foramen on axial MR images. The sagittal shoulder sign was identified with a mean frequency of 90.9% by the two observers (in 10 of 11 patients). The common passage of two consecutive nerve roots through the neural foramen on axial MR images was identified with a mean frequency of 59.1% (in 7 and 6 out of 11 patients, by observers 1 and 2, respectively). Good interobserver agreement for the sagittal shoulder sign was present (k = 0.621, p < 0.05). Observation of the sagittal shoulder sign may prove helpful for diagnosing CLNR in patients with disk herniation. In particular, this sign appears to be useful when there is no evidence of CLNR on axial MR images. (orig.)

  5. Integrated lasers in crystalline double tungstates with focused-ion-beam nanostructured photonic cavities

    International Nuclear Information System (INIS)

    Ay, F; Iñurrategui, I; Geskus, D; Aravazhi, S; Pollnau, M

    2011-01-01

    Deeply etched Bragg gratings were fabricated by focused ion beam (FIB) milling in KGd x Lu 1-x (WO 4 ) 2 :Yb 3+ to obtain photonic cavity structures. By optimizing parameters such as dose per area, dwell time and pixel resolution the redeposition effects were minimized and grating structures more than 4 μm in depth with an improved sidewall angle of ∼ 5° were achieved. Fabry-Perot microcavities were defined and used to assess the optical performance of the grating structures at ∼ 1530 nm. An on-chip integrated laser cavity at ∼ 980 nm was achieved by defining a FIB reflective grating and FIB polished waveguide end-facet. With this cavity, an on-chip integrated waveguide laser in crystalline potassium double tungstate was demonstrated

  6. Not all sagittal band tears come with extensor instability. A case report with radiological and operative correlation

    International Nuclear Information System (INIS)

    Li, Shuo; Jacob, Jubin; Ghasemiesfe, Ahmadreza; Marrinan, Greg B.; Brooks, Jeffrey J.

    2018-01-01

    The sagittal bands are a component of the extensor hood. They serve an important role in stabilizing the extensor tendon by forming a ''check-rein'' to radial-ulnar translation of the tendon over the metacarpal head, and extending the metacarpophalangeal (MCP) joint by virtue of attaching the extensor tendon to the palmar plate. Injury to the sagittal band is thought to cause extensor instability and subluxation to the contralateral side by disruption of this ''check-rein'' function, although recent evidence from cadaver studies suggests that ulnar sagittal band tear may be spared of extensor instability. As a case in point, we encountered a patient with surgically proven ulnar sagittal band tear, who did not have any extensor tendon subluxation or any limitation in motion. Intraoperative findings demonstrated a chronic-appearing ulnar sagittal band tear, indicating that chronic injury with fibrosis may stabilize the central band. Therefore, in patients with metacarpophalangeal pain without central tendon subluxation or limitation of motion, it remains important to raise the concern of sagittal band tear for appropriate treatment. We present the clinical course of this case, with radiological and operative findings, followed by a review of the relevant literature. (orig.)

  7. Not all sagittal band tears come with extensor instability. A case report with radiological and operative correlation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shuo; Jacob, Jubin; Ghasemiesfe, Ahmadreza; Marrinan, Greg B. [Yale New Haven Health Bridgeport Hospital, Bridgeport, CT (United States); Brooks, Jeffrey J. [Orthopedic Surgery and Sports Medicine Center, New Canaan, CT (United States)

    2018-04-15

    The sagittal bands are a component of the extensor hood. They serve an important role in stabilizing the extensor tendon by forming a ''check-rein'' to radial-ulnar translation of the tendon over the metacarpal head, and extending the metacarpophalangeal (MCP) joint by virtue of attaching the extensor tendon to the palmar plate. Injury to the sagittal band is thought to cause extensor instability and subluxation to the contralateral side by disruption of this ''check-rein'' function, although recent evidence from cadaver studies suggests that ulnar sagittal band tear may be spared of extensor instability. As a case in point, we encountered a patient with surgically proven ulnar sagittal band tear, who did not have any extensor tendon subluxation or any limitation in motion. Intraoperative findings demonstrated a chronic-appearing ulnar sagittal band tear, indicating that chronic injury with fibrosis may stabilize the central band. Therefore, in patients with metacarpophalangeal pain without central tendon subluxation or limitation of motion, it remains important to raise the concern of sagittal band tear for appropriate treatment. We present the clinical course of this case, with radiological and operative findings, followed by a review of the relevant literature. (orig.)

  8. The relationship between changes of cervical sagittal alignment after anterior cervical discectomy and fusion and spino-pelvic sagittal alignment under roussouly classification: a four-year follow-up study.

    Science.gov (United States)

    Huang, Dong-Ning; Yu, Miao; Xu, Nan-Fang; Li, Mai; Wang, Shao-Bo; Sun, Yu; Jiang, Liang; Wei, Feng; Liu, Xiao-Guang; Liu, Zhong-Jun

    2017-02-20

    Anterior cervical discectomy and fusion (ACDF) is widely used in the treatment of cervical degenerative disease; however, the variation of cervical sagittal alignment changes after ACDF has been rarely explored. The purpose of this study is to determine the relationship between changes of cervical sagittal alignment after ACDF and spino-pelvic sagittal alignment under Roussouly classification. A cohort of 133 Chinese cervical spondylotic patients who received ACDF from 2011 to 2012 was recruited. All patients were categorized with Roussouly Classification. Lateral X-ray images of global spine were obtained, and preoperative and postoperative parameters were measured and analyzed, including C2-C7 angles (C2-C7), C0-C7 angles (C0-C7), external auditory meatus (EAM) tilt, sacral slope (SS), thoracic kyphosis (TK), lumbar lordosis (LL), spinal sacral angles (SSA), Superior adjacent inter-vertebral angle (SAIV), inferior adjacent inter-vertebral angle (IAIV) and et al. The Wilcoxon signed-rank test was used for intragroup comparisons preoperatively and at postoperative 48 months. Among the parameters, C2-C7 and C0-C7 showed significant increase, while EAM TK, and IAIV decreased significantly. In type I, EAM and TK decreased significantly, however SS showed a significant increase; in type II, TK showed a significant decrease, but SSA showed a significant increase; in type III, a significant increase of C0-C7 was observed with a significant decrease in EAM, nevertheless, LL, SS and SSA showed significant decreases; and in type IV, C2-C7 showed a significant increase and EAM decreased significantly. The percentage of lordotic alignment in cervical spine increased, which was presenting in type I, III and IV. Nevertheless, the amount of patients with straight cervical alignment increased in type II. The backward movement of head occurs is the compensatory mechanism in cervical sagittal alignment modifications after ACDF. The compensatory alteration of spino-pelvic sagittal

  9. The relationship between changes of cervical sagittal alignment after anterior cervical discectomy and fusion and spino-pelvic sagittal alignment under roussouly classification: a four-year follow-up study

    Directory of Open Access Journals (Sweden)

    Dong-Ning Huang

    2017-02-01

    Full Text Available Abstract Background Anterior cervical discectomy and fusion (ACDF is widely used in the treatment of cervical degenerative disease; however, the variation of cervical sagittal alignment changes after ACDF has been rarely explored. The purpose of this study is to determine the relationship between changes of cervical sagittal alignment after ACDF and spino-pelvic sagittal alignment under Roussouly classification. Methods A cohort of 133 Chinese cervical spondylotic patients who received ACDF from 2011 to 2012 was recruited. All patients were categorized with Roussouly Classification. Lateral X-ray images of global spine were obtained, and preoperative and postoperative parameters were measured and analyzed, including C2–C7 angles (C2–C7, C0–C7 angles (C0–C7, external auditory meatus (EAM tilt, sacral slope (SS, thoracic kyphosis (TK, lumbar lordosis (LL, spinal sacral angles (SSA, Superior adjacent inter-vertebral angle (SAIV, inferior adjacent inter-vertebral angle (IAIV and et al. The Wilcoxon signed-rank test was used for intragroup comparisons preoperatively and at postoperative 48 months. Results Among the parameters, C2–C7 and C0–C7 showed significant increase, while EAM TK, and IAIV decreased significantly. In type I, EAM and TK decreased significantly, however SS showed a significant increase; in type II, TK showed a significant decrease, but SSA showed a significant increase; in type III, a significant increase of C0–C7 was observed with a significant decrease in EAM, nevertheless, LL, SS and SSA showed significant decreases; and in type IV, C2–C7 showed a significant increase and EAM decreased significantly. The percentage of lordotic alignment in cervical spine increased, which was presenting in type I, III and IV. Nevertheless, the amount of patients with straight cervical alignment increased in type II. Conclusion The backward movement of head occurs is the compensatory mechanism in cervical sagittal alignment

  10. Accuracy of the sagittal vertical axis in a standing lateral radiograph as a measurement of balance in spinal deformities

    NARCIS (Netherlands)

    van Royen, B.J.; Toussaint, H.M.; Kingma, I.; Bot, S.D.M.; Caspers, M.; Harlaar, J.

    1998-01-01

    Sagittal balance of the spine is becoming an important issue in the assessment of the degree of spinal deformity. On a standing lateral full- length radiograph of the spine, the plumb line, or sagittal vertical axis (SVA), can be used to determine the spinal sagittal balance. In this procedure

  11. Sagittal plane tilting deformity of the patellofemoral joint: a new concept in patients with chondromalacia patella.

    Science.gov (United States)

    Aksahin, Ertugrul; Aktekin, Cem Nuri; Kocadal, Onur; Duran, Semra; Gunay, Cüneyd; Kaya, Defne; Hapa, Onur; Pepe, Murad

    2017-10-01

    The aims of this study were to evaluate sagittal plane alignment in patients with chondromalacia patella via magnetic resonance imaging (MRI), analyse the relationships between the location of the patellar cartilaginous lesions and sagittal alignment and finally investigate the relationships between the sagittal plane malalignment and patellofemoral loadings using by finite element analysis. Fifty-one patients who were diagnosed with isolated modified Outerbridge grade 3-4 patellar chondromalacia based on MRI evaluation and 51 control subjects were evaluated. Chondromalacia patella patients were divided into three subgroups according to the chondral lesion location as superior, middle and inferior. The patella-patellar tendon angle (P-PT) was used for evaluation of sagittal alignment of patellofemoral joint. Each subgroup was compared with control group by using P-PT angle. To investigate the biomechanical effects of sagittal plane malpositioning on patellofemoral joint, bone models were created at 30°, 60° and 90° knee flexion by using mean P-PT angles, which obtained from patients with chondromalacia patellae and control subjects. The total loading and contact area values of the patellofemoral joints were investigated by finite element analysis. The mean age of all participants was 52.9 ± 8.2 years. The mean P-PT angle was significantly lower in chondromalacia group (142.1° ± 3.6°) compared to control group (144.5° ± 5.3°) (p = 0.008). Chondral lesions were located in superior, middle and inferior zones in 16, 20 and 15 patients, respectively. The mean P-PT angles in patients with superior (141.8 ± 2.7) and inferior subgroups (139.2 ± 2.3) were significantly lower than the values in the control group (p chondromalacia than in the control models at the same flexion degrees. There were increased loadings at 30° and 90° flexions in the sagittal patellar tilt models. This study revealed that sagittal plain malpositioning of the

  12. Superior sagittal sinus thrombosis: a rare complication in a child with nephrotic syndrome

    International Nuclear Information System (INIS)

    Pirogovsky, A.; Adi, M.; Barzilai, N.; Dagan, A.; Sinai, L.; Sthoeger, D.; Tabachnik, E.

    2001-01-01

    A 2-year-old boy with new-onset nephrotic syndrome developed recurrent vomiting, apathy and papilloedema. Superior sagittal sinus thrombosis was diagnosed on cranial CT and MRI. He gradually recovered after treatment with heparin, fresh frozen plasma and warfarin with complete resolution of the thrombosis after 1 month. Superior sagittal sinus thrombosis is an extremely rare complication of nephrotic syndrome in children. Early diagnosis is essential for institution of anticoagulation therapy and a successful outcome. (orig.)

  13. Superior sagittal sinus thrombosis: a rare complication in a child with nephrotic syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Pirogovsky, A.; Adi, M.; Barzilai, N. [Dept. of Radiology, Kaplan Medical Center, Rehovot (Israel); Dagan, A.; Sinai, L.; Sthoeger, D. [Div. of Paediatrics, Kaplan Medical Center, Rehovot (Israel); Tabachnik, E. [Div. of Paediatrics, Kaplan Medical Center, Rehovot (Israel); Paediatric ICU, Kaplan Hospital, Rehovot (Israel)

    2001-10-01

    A 2-year-old boy with new-onset nephrotic syndrome developed recurrent vomiting, apathy and papilloedema. Superior sagittal sinus thrombosis was diagnosed on cranial CT and MRI. He gradually recovered after treatment with heparin, fresh frozen plasma and warfarin with complete resolution of the thrombosis after 1 month. Superior sagittal sinus thrombosis is an extremely rare complication of nephrotic syndrome in children. Early diagnosis is essential for institution of anticoagulation therapy and a successful outcome. (orig.)

  14. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Science.gov (United States)

    Yang, Yang; Fang, Ying; Zhang, Xini; He, Junliang; Fu, Weijie

    2017-01-01

    The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively) performed a weight-bearing dorsiflexion (WB-DF) maneuver, drop jumps (DJs), and lay-up jumps (LJs). Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041) was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028) and power (p = 0.022) were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion–extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane. Key points An increased shoe collar height effectively reduced ankle joint ROM in the sagittal plane in weight-bearing dorsiflexion maneuver. Shoe collar height did not affect sagittal plane ankle kinematics and had no effect on performance during realistic jumping. Shoe collar height can affect the ankle plantarflexion torque and peak power during the push-off phase in lay-up jump. PMID:29238255

  15. Sagittal alignment and complications following lumbar 3-column osteotomy: does the level of resection matter?

    Science.gov (United States)

    Ferrero, Emmanuelle; Liabaud, Barthelemy; Henry, Jensen K; Ames, Christopher P; Kebaish, Khaled; Mundis, Gregory M; Hostin, Richard; Gupta, Munish C; Boachie-Adjei, Oheneba; Smith, Justin S; Hart, Robert A; Obeid, Ibrahim; Diebo, Bassel G; Schwab, Frank J; Lafage, Virginie

    2017-11-01

    OBJECTIVE Three-column osteotomy (3CO) is a demanding technique that is performed to correct sagittal spinal malalignment. However, the impact of the 3CO level on pelvic or truncal sagittal correction remains unclear. In this study, the authors assessed the impact of 3CO level and postoperative apex of lumbar lordosis on sagittal alignment correction, complications, and revisions. METHODS In this retrospective study of a multicenter spinal deformity database, radiographic data were analyzed at baseline and at 1- and 2-year follow-up to quantify spinopelvic alignment, apex of lordosis, and resection angle. The impact of 3CO level and apex level of lumbar lordosis on the sagittal correction was assessed. Logistic regression analyses were performed, controlling for cofounders, to investigate the effects of 3CO level and apex level on intraoperative and postoperative complications as well as on the need for subsequent revision surgery. RESULTS A total of 468 patients were included (mean age 60.8 years, mean body mass index 28.1 kg/m 2 ); 70% of patients were female. The average 3CO resection angle was 25.1° and did not significantly differ with regard to 3CO level. There were no significant correlations between the 3CO level and amount of sagittal vertical axis or pelvic tilt correction. The postoperative apex level significantly correlated with greater correction of pelvic tilt (2° per more caudal level, R = -0.2, p = 0.006). Lower-level 3CO significantly correlated with revisions for pseudarthrosis (OR = 3.88, p = 0.001) and postoperative motor deficits (OR = 2.02, p = 0.026). CONCLUSIONS In this study, a more caudal lumbar 3CO level did not lead to greater sagittal vertical axis correction. The postoperative apex of lumbar lordosis significantly impacted pelvic tilt. 3CO levels that were more caudal were associated with more postoperative motor deficits and revisions.

  16. Bad splits in bilateral sagittal split osteotomy: systematic review of fracture patterns.

    Science.gov (United States)

    Steenen, S A; Becking, A G

    2016-07-01

    An unfavourable and unanticipated pattern of the mandibular sagittal split osteotomy is generally referred to as a 'bad split'. Few restorative techniques to manage the situation have been described. In this article, a classification of reported bad split pattern types is proposed and appropriate salvage procedures to manage the different types of undesired fracture are presented. A systematic review was undertaken, yielding a total of 33 studies published between 1971 and 2015. These reported a total of 458 cases of bad splits among 19,527 sagittal ramus osteotomies in 10,271 patients. The total reported incidence of bad split was 2.3% of sagittal splits. The most frequently encountered were buccal plate fractures of the proximal segment (types 1A-F) and lingual fractures of the distal segment (types 2A and 2B). Coronoid fractures (type 3) and condylar neck fractures (type 4) have seldom been reported. The various types of bad split may require different salvage approaches. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Influence of the sagittal anatomy of the pelvis on the intercrestal line position.

    Science.gov (United States)

    Horduna, M; Legaye, J

    2008-03-01

    The line joining the two iliac crests is classically regarded as the anatomical landmark determining the inter-vertebral space L4-L5 for the spinal punctures. Its variability has been reported but never related to predictive clinical anatomic factors identifying patients groups in which there is increased risk of miscalculation of the spinal level. Two sagittal pelvic anatomical angles, called 'pelvic incidence' and 'pelvic lordosis' were measured on lateral X-rays of the pelvis of 132 normal individuals and 49 spondylolysis patients. The values were compared with the sagittal projection of the intercrestal line on the disco-vertebral lumbar structures. A strict relation was observed between this projection of the intercrestal line and the sagittal pelvic anatomical angles. The greater the pelvic incidence, the higher the intercrestal line was projected, all the more in patients with spondylolysis with a listhesis or a disc narrowing. The relation between the pelvic sagittal angles and the intercrestal line projection explains the variability described for this anatomical landmark. It implies precautions minimizing neurological risk in the case of a puncture carried out more cranially than expected, particularly for high values of pelvic incidence occurring in spinal pathologies such as spondylolysis, in the elderly or in the obese patients. In these cases, we recommend the use of spinal imaging during the procedure to assist selection of the desired insertion level.

  18. Application of focused ion beam technology for photonic nanostructures

    NARCIS (Netherlands)

    Ay, F.; Gadgil, V.J.; Geskus, D.; Aravazhi, S.; Worhoff, Kerstin; Pollnau, Markus

    Al2O3 and KY(WO4)2 are promising materials for photonic applications with excellent optical properties and of interest for obtaining on chip resonator structures. However, there is no method available to fabricate these structures except FIB technology. We will discuss strategies to optimize the

  19. Solid-state single-photon emitters

    Science.gov (United States)

    Aharonovich, Igor; Englund, Dirk; Toth, Milos

    2016-10-01

    Single-photon emitters play an important role in many leading quantum technologies. There is still no 'ideal' on-demand single-photon emitter, but a plethora of promising material systems have been developed, and several have transitioned from proof-of-concept to engineering efforts with steadily improving performance. Here, we review recent progress in the race towards true single-photon emitters required for a range of quantum information processing applications. We focus on solid-state systems including quantum dots, defects in solids, two-dimensional hosts and carbon nanotubes, as these are well positioned to benefit from recent breakthroughs in nanofabrication and materials growth techniques. We consider the main challenges and key advantages of each platform, with a focus on scalable on-chip integration and fabrication of identical sources on photonic circuits.

  20. Photonic Crystal Laser-Driven Accelerator Structures

    International Nuclear Information System (INIS)

    Cowan, B

    2004-01-01

    The authors discuss simulated photonic crystal structure designs for laser-driven particle acceleration. They focus on three-dimensional planar structures based on the so-called ''woodpile'' lattice, demonstrating guiding of a speed-of-light accelerating mode by a defect in the photonic crystal lattice. They introduce a candidate geometry and discuss the properties of the accelerating mode. They also discuss the linear beam dynamics in the structure present a novelmethod for focusing the beam. In addition they describe ongoing investigations of photonic crystal fiber-based structures

  1. Reliability of the xipho-pubic angle in patients with sagittal imbalance of the spine.

    Science.gov (United States)

    Langella, Francesco; Villafañe, Jorge H; Ismael, Maryem; Buric, Josip; Piazzola, Andrea; Lamartina, Claudio; Berjano, Pedro

    2018-04-01

    Proximal junctional kyphosis (PJK) is a frequent complication that compromises the outcomes of spinal surgery, especially for adult deformity. To the date no single risk factor or cause has been identified that explains its occurrence. The purpose of this study was to investigate the test-retest reliability of the radiologic measurements using xipho-pubic angle (XPA) for subjects undergoing surgery for sagittal misalignment of the spine. Retrospective observational cross-sectional study of prospectively collected data. Full-spine standing lateral radiographs of 50 patients who underwent surgery for fixed sagittal imbalance (preoperative and postoperative) were evaluated. Internal consistency, reproducibility, concurrent validity, and discriminative ability of the XPA. Two physicians measured XPA on the 100 randomly sorted and anonymized radiographs on two occasions, one week apart (test and retest conditions), were calculated for inter and intraobserver agreement. Test-retest reliability of XPA measurement was excellent for pre- (ICC=0.98; P=0.001) and post-surgical (ICC=0.86; P=0.001) radiographs of subjects with sagittal imbalance of the spine. XPA was able to discriminate between preoperative and postoperative radiographs F=17.924, Pimbalance for both raters. There were significant differences between pre- vs. postoperative XPA, pelvic tilt, lumbar lordosis and sagittal vertical axis values (all Pimbalance.

  2. Relationship between thoracic hypokyphosis, lumbar lordosis and sagittal pelvic parameters in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Clément, Jean-Luc; Geoffray, Anne; Yagoubi, Fatima; Chau, Edouard; Solla, Federico; Oborocianu, Ioana; Rampal, Virginie

    2013-11-01

    Sagittal spine and pelvic alignment of adolescent idiopathic scoliosis (AIS) is poorly described in the literature. It generally reports the sagittal alignment with regard to the type of curve and never correlated to the thoracic kyphosis. The objective of this study is to investigate the relationship between thoracic kyphosis, lumbar lordosis and sagittal pelvic parameters in thoracic AIS. Spinal and pelvic sagittal parameters were evaluated on lateral radiographs of 86 patients with thoracic AIS; patients were separated into hypokyphosis group (n = 42) and normokyphosis group (n = 44). Results were statistically analyzed. The lumbar lordosis was lower in the hypokyphosis group, due to the low proximal lordosis. The thoracic kyphosis was not correlated with any pelvic parameters but with the proximal lordosis. The pelvic incidence was correlated with sacral slope, pelvic tilt, lumbar lordosis and highly correlated with distal lumbar lordosis in the two groups. There was a significant linear regression between thoracic kyphosis and proximal lordosis and between pelvic incidence and distal lordosis. We can consider that the proximal part of the lordosis depends on the thoracic kyphosis and the distal part depends on the pelvic incidence. The hypokyphosis in AIS is independent of the pelvic parameters and could be described as a structural parameter, characteristic of the scoliotic deformity.

  3. Extensor Tendon Instability Due to Sagittal Band Injury in a Martial Arts Athlete: A Case Report.

    Science.gov (United States)

    Kochevar, Andrew; Rayan, Ghazi

    2017-03-01

    A Taekwondo participant sustained a hand injury from punching an opponent that resulted in painful instability of the ring finger extensor digitorum communis tendon due to sagittal band damage. His symptoms resolved after reconstructive surgery on the sagittal band (SB) with stabilization of the extensor tendon over the metacarpophalangeal joint.

  4. Anterior sagittal transanorectal approach to the posterior urethra in the pediatric age group.

    Science.gov (United States)

    Rossi, F; De Castro, R; Ceccarelli, P L; Dòmini, R

    1998-09-01

    Surgical access to the posterior urethra is often difficult and several surgical solutions have been proposed. We suggest an anterior sagittal transanorectal approach based on splitting the anterior rectal wall only. This alternative technique provides excellent exposure to the retrourethral region, permitting simple and safe surgery. Between 1994 and 1996 we performed surgery via the anterior sagittal transanorectal approach in 8 patients with a mean age of 9.06 years. Patients included 1 girl with a posttraumatic urethrovaginal fistula, 3 with intersex disorders (2 with mixed gonadal dysgenesis raised as boys and 1 with male dysgenetic pseudohermaphroditism with an enlarged urtricle) and 4 boys (1 with penile agenesis raised as girl, 2 with urethral duplication and 1 with prostatic rhabdomyosarcoma). The patient was placed in a knee-chest position. A midline sagittal incision was made through the anterior anorectal wall only and deepened through the perineal body to expose the posterior urethra and retrovesical space. After the pathological condition was corrected the anterior rectal wall and perineal body were reconstructed. The operation was completed with protective colostomy. In our final patient with prostatic rhabdomyosarcoma the anterior sagittal transanorectal approach was used without colostomy. Anorectal manometry was done 6 months postoperatively. All patients were completely continent of stool and urine. Convalescence was unremarkable in all cases. Postoperative manometry in 7 patients revealed no differences from preoperative measurements. This procedure should be considered a useful alternative to other techniques for various congenital and acquired pelvic disorders.

  5. Impact of sagittal spinopelvic alignment on clinical outcomes after decompression surgery for lumbar spinal canal stenosis without coronal imbalance.

    Science.gov (United States)

    Hikata, Tomohiro; Watanabe, Kota; Fujita, Nobuyuki; Iwanami, Akio; Hosogane, Naobumi; Ishii, Ken; Nakamura, Masaya; Toyama, Yoshiaki; Matsumoto, Morio

    2015-10-01

    The object of this study was to investigate correlations between sagittal spinopelvic alignment and improvements in clinical and quality-of-life (QOL) outcomes after lumbar decompression surgery for lumbar spinal canal stenosis (LCS) without coronal imbalance. The authors retrospectively reviewed data from consecutive patients treated for LCS with decompression surgery in the period from 2009 through 2011. They examined correlations between preoperative or postoperative sagittal vertical axis (SVA) and radiological parameters, clinical outcomes, and health-related (HR)QOL scores in patients divided according to SVA. Clinical outcomes were assessed according to Japanese Orthopaedic Association (JOA) and visual analog scale (VAS) scores. Health-related QOL was evaluated using the Roland-Morris Disability Questionnaire (RMDQ) and the JOA Back Pain Evaluation Questionnaire (JOABPEQ). One hundred nine patients were eligible for inclusion in the study. Compared to patients with normal sagittal alignment prior to surgery (Group A: SVA imbalance (Group B: SVA ≥ 50 mm) had significantly smaller lumbar lordosis and thoracic kyphosis angles and larger pelvic tilt. In Group B, there was a significant decrease in postoperative SVA compared with the preoperative SVA (76.3 ± 29.7 mm vs. 54.3 ± 39.8 mm, p = 0.004). The patients in Group B with severe preoperative sagittal imbalance (SVA > 80 mm) had residual sagittal imbalance after surgery (82.8 ± 41.6 mm). There were no significant differences in clinical and HRQOL outcomes between Groups A and B. Compared to patients with normal postoperative SVA (Group C: SVA imbalance. Decompression surgery improved the SVA value in patients with preoperative sagittal imbalance; however, the patients with severe preoperative sagittal imbalance (SVA > 80 mm) had residual imbalance after decompression surgery. Both clinical and HRQOL outcomes were negatively affected by postoperative residual sagittal imbalance.

  6. Alphabet Soup: Sagittal Balance Correction Osteotomies of the Spine-What Radiologists Should Know.

    Science.gov (United States)

    Takahashi, T; Kainth, D; Marette, S; Polly, D

    2018-04-01

    Global sagittal malalignment has been demonstrated to have correlation with clinical symptoms and is a key component to be restored in adult spinal deformity. In this article, various types of sagittal balance-correction osteotomies are reviewed primarily on the basis of the 3 most commonly used procedures: Smith-Petersen osteotomy, pedicle subtraction osteotomy, and vertebral column resection. Familiarity with the expected imaging appearance and commonly encountered complications seen on postoperative imaging studies following correction osteotomies is crucial for accurate image interpretation. © 2018 by American Journal of Neuroradiology.

  7. Evaluation of uterine peristalsis using cine MRI on the coronal plane in comparison with the sagittal plane.

    Science.gov (United States)

    Shitano, Fuki; Kido, Aki; Kataoka, Masako; Fujimoto, Koji; Kiguchi, Kayo; Fushimi, Yasutaka; Togashi, Kaori

    2016-01-01

    Uterine peristalsis is supposed to be closely related to the early stages of reproduction. Sperms are preferentially transported from the uterine cervix to the side of the tube with the dominant follicle. However, with respect to magnetic resonance imaging (MRI), uterine peristalsis has only been evaluated at the sagittal plane of cine MRI. To evaluate and compare uterine peristalsis both on sagittal and coronal planes using cine MRI. Internal ethics committee approval was obtained, and subjects provided informed written consent. Thirty-one women underwent MRI scans in the periovulatory phase of the menstrual cycle. Cine MR images obtained by fast advanced spin echo sequence at 3-T field strength magnet (Toshiba Medical Systems) were visually evaluated by two independent radiologists. The frequency and the direction of peristalsis, and the presence of outer myometrium conduction of signal intensities (OMC), were evaluated. The laterality of the dominant follicle was determined on axial images and compared with the peristaltic direction in fundus. The subjects in which peristaltic directions were more clearly recognized were significantly frequent in coronal planes than in sagittal planes (P < 0.05). There was no significant difference in the peristaltic frequency between the sagittal and the coronal plane. However, the OMC was more recognized in the coronal plane than in the sagittal plane (P < 0.05). Peristaltic waves conducted toward the possible ovulation side were observed in only three of the 10 subjects. OMC of uterine peristalsis was better demonstrated in the coronal plane compared to the sagittal plane. © The Foundation Acta Radiologica 2015.

  8. Gender difference of ankle stability in the sagittal and frontal planes.

    Science.gov (United States)

    Hanzlick, Harrison; Hyunglae Lee

    2017-07-01

    This paper offers quantification of ankle stability in relation to simulated haptic environments of varying stiffness. This study analyzes the stability trends of male and female subjects independently over a wide range of simulated environments after subjects were exposed to vigorous position perturbation. Ankle stability was quantified for both degrees-of-freedom of the ankle in the sagittal and frontal planes. Subjects' stability consistently decreased when exposed to environments of negative simulated stiffness. In the frontal plane, male and female subjects exhibited nearly identical stability levels. In the sagittal plane, however, male subjects demonstrated marginally more stability than female subjects in environments with negative stiffness. Results of this study are beneficial to understanding situations in which the ankle is likely to lose stability, potentially resulting in injury.

  9. Silicon photonic integration in telecommunications

    Directory of Open Access Journals (Sweden)

    Christopher Richard Doerr

    2015-08-01

    Full Text Available Silicon photonics is the guiding of light in a planar arrangement of silicon-based materials to perform various functions. We focus here on the use of silicon photonics to create transmitters and receivers for fiber-optic telecommunications. As the need to squeeze more transmission into a given bandwidth, a given footprint, and a given cost increases, silicon photonics makes more and more economic sense.

  10. Theory of the cancellation of 4-photon resonances by an off-resonance 3-photon cancellation

    DEFF Research Database (Denmark)

    Elk, M.; Lambropoulos, P.; Tang, X.

    1992-01-01

    We present a complete account of our recent work [Phys. Rev. A 44, 31 (1991)] in which we investigate the theory of cancellation by interference between the absorption of three fundamental laser photons and one third-harmonic photon. The theory is formulated in terms of the density matrix so...... as to take detunings, dephasing, and laser bandwidth into account. The result is a theory of cancellation for finite detuning that explains how four-photon resonances can be canceled by a three-photon mechanism if there is an atomic level at near-three-photon resonance. The treatment is extended to focused...

  11. Video raster stereography back shape reconstruction: a reliability study for sagittal, frontal, and transversal plane parameters.

    Science.gov (United States)

    Schroeder, J; Reer, R; Braumann, K M

    2015-02-01

    As reliability of raster stereography was proved only for sagittal plane parameters with repeated measures on the same day, the present study was aiming at investigating variability and reliability of back shape reconstruction for all dimensions (sagittal, frontal, transversal) and for different intervals. For a sample of 20 healthy volunteers, intra-individual variability (SEM and CV%) and reliability (ICC ± 95% CI) were proved for sagittal (thoracic kyphosis, lumbar lordosis, pelvis tilt angle, and trunk inclination), frontal (pelvis torsion, pelvis and trunk imbalance, vertebral side deviation, and scoliosis angle), transversal (vertebral rotation), and functional (hyperextension) spine shape reconstruction parameters for different test-retest intervals (on the same day, between-day, between-week) by means of video raster stereography. Reliability was high for the sagittal plane (pelvis tilt, kyphosis and lordosis angle, and trunk inclination: ICC > 0.90), and good to high for lumbar mobility (0.86 < ICC < 0.97). Apart from sagittal plane spinal alignment, there was a lack of certainty for a high reproducibility indicated by wider ICC confidence intervals. So, reliability was fair to high for vertebral side deviation and the scoliosis angle (0.71 < ICC < 0.95), and poor to good for vertebral rotation values as well as for frontal plane upper body and pelvis position parameters (0.65 < ICC < 0.92). Coefficients for the between-day and between-week interval were a little lower than for repeated measures on the same day. Variability (SEM) was less than 1.5° or 1.5 mm, except for trunk inclination. Relative variability (CV) was greater in global trunk position and pelvis parameters (35-98%) than in scoliosis (14-20%) or sagittal sway parameters (4-8 %). Although we found a lower reproducibility for the frontal plane, raster stereography is considered to be a reliable method for the non-invasive, three-dimensional assessment of spinal alignment in normal non

  12. Postural Consequences of Cervical Sagittal Imbalance: A Novel Laboratory Model.

    Science.gov (United States)

    Patwardhan, Avinash G; Havey, Robert M; Khayatzadeh, Saeed; Muriuki, Muturi G; Voronov, Leonard I; Carandang, Gerard; Nguyen, Ngoc-Lam; Ghanayem, Alexander J; Schuit, Dale; Patel, Alpesh A; Smith, Zachary A; Sears, William

    2015-06-01

    A biomechanical study using human spine specimens. To study postural compensations in lordosis angles that are necessary to maintain horizontal gaze in the presence of forward head posture and increasing T1 sagittal tilt. Forward head posture relative to the shoulders, assessed radiographically using the horizontal offset distance between the C2 and C7 vertebral bodies (C2-C7 [sagittal vertical alignment] SVA), is a measure of global cervical imbalance. This may result from kyphotic alignment of cervical segments, muscle imbalance, as well as malalignment of thoracolumbar spine. Ten cadaveric cervical spines (occiput-T1) were tested. The T1 vertebra was anchored to a tilting and translating base. The occiput was free to move vertically but its angular orientation was constrained to ensure horizontal gaze regardless of sagittal imbalance. A 5-kg mass was attached to the occiput to mimic head weight. Forward head posture magnitude and T1 tilt were varied and motions of individual vertebrae were measured to calculate C2-C7 SVA and lordosis across C0-C2 and C2-C7. Increasing C2-C7 SVA caused flexion of lower cervical (C2-C7) segments and hyperextension of suboccipital (C0-C1-C2) segments to maintain horizontal gaze. Increasing kyphotic T1 tilt primarily increased lordosis across the C2-C7 segments. Regression models were developed to predict the compensatory C0-C2 and C2-C7 angulation needed to maintain horizontal gaze given values of C2-C7 SVA and T1 tilt. This study established predictive relationships between radiographical measures of forward head posture, T1 tilt, and postural compensations in the cervical lordosis angles needed to maintain horizontal gaze. The laboratory model predicted that normalization of C2-C7 SVA will reduce suboccipital (C0-C2) hyperextension, whereas T1 tilt reduction will reduce the hyperextension in the C2-C7 segments. The predictive relationships may help in planning corrective strategy in patients experiencing neck pain, which may be

  13. A morphological description of the sagittal otoliths of two mormyrids ...

    African Journals Online (AJOL)

    The morphology of the sagittal otoliths of two South African mormyrid fish, Marcusenius macrolepidotus and Petrocephalus catostoma, were studied to determine possible morphological significance. The sagittae of M. macrolepidotus and P. catostoma are kidney-shaped and oblong, respectively. The ventral margin is ...

  14. Sagittal balance, a useful tool for neurosurgeons?

    Science.gov (United States)

    Villard, Jimmy; Ringel, Florian; Meyer, Bernhard

    2014-01-01

    New instrumentation techniques have made any correction of the spinal architecture possible. Sagittal balance has been described as an important parameter for assessing spinal deformity in the early 1970s, but over the last decade its importance has grown with the published results in terms of overall quality of life and fusion rate. Up until now, most of the studies have concentrated on spinal deformity surgery, but its use in the daily neurosurgery practice remains uncertain and may warrant further studies.

  15. The Role of Proprioception in the Sagittal Setting of Anticipatory Postural Adjustments During Gait Initiation

    OpenAIRE

    Pereira Marcelo P.; Pelicioni Paulo H. Silva; Gobbi Lilian T.B.

    2015-01-01

    Purpose. Previous studies have studied the role of proprioception on the setting of anticipatory postural adjustments (APA) during gait initiation. However, these studies did not investigate the role of proprioception in the sagittal APA setting. We aimed to investigate the role of proprioception manipulation to induce APA sagittal adaptations on gait initiation. Methods. Fourteen healthy adults performed gait initiation without, and with, vibration applied before movement onset, and during m...

  16. Usefulness of the dynamic gadolinium-enhanced magnetic resonance imaging with simultaneous acquisition of coronal and sagittal planes for detection of pituitary microadenomas.

    Science.gov (United States)

    Lee, Han Bee; Kim, Sung Tae; Kim, Hyung-Jin; Kim, Keon Ha; Jeon, Pyoung; Byun, Hong Sik; Choi, Jin Wook

    2012-03-01

    Does dynamic gadolinium-enhanced imaging with simultaneous acquisition of coronal and sagittal planes improve diagnostic accuracy of pituitary microadenomas compared with coronal images alone? Fifty-six patients underwent 3-T sella MRI including dynamic simultaneous acquisition of coronal and sagittal planes after gadolinium injection. According to conspicuity, lesions were divided into four scores (0, no; 1, possible; 2, probable; 3, definite delayed enhancing lesion). Additional information on supplementary sagittal images compared with coronal ones was evaluated with a 4-point score (0, no; 1, possible; 2, probable; 3, definite additional information). Accuracy of tumour detection was calculated. Average scores for lesion detection of a combination of two planes, coronal, and sagittal images were 2.59, 2.32, and 2.18. 6/10 lesions negative on coronal images were detected on sagittal ones. Accuracy of a combination of two planes, of coronal and of sagittal images was 92.86%, 82.14% and 75%. Six patients had probable or definite additional information on supplementary sagittal images compared with coronal ones alone (10.71%). Dynamic MRI with combined coronal and sagittal planes was more accurate for detection of pituitary microadenomas than routinely used coronal images. Simultaneous dynamic enhanced acquisition can make study time fast and costs low. We present a new dynamic MRI technique for evaluating pituitary microadenomas • This technique provides simultaneous acquisition of contrast enhanced coronal and sagittal images. • This technique makes the diagnosis more accurate and reduces the examination time. • Such MR imaging only requires one single bolus of contrast agent.

  17. Body posture in the sagittal plane and scoliotic variables in girls aged 7-18

    Directory of Open Access Journals (Sweden)

    Jacek Wilczyński

    2018-02-01

    Introduction. The aim of the study was to analyze the correlation between the variable posture in the sagittal plane and the scoliotic variables. Material and methods. The study involved 28 girls aged 7-18 years with scoliotic posture and scoliosis. Body posture as well as the spine were examined using Moiré’s spatial photogrammetry and the Exhibeon digital radiography method. Based on the size of the spinal curvature, the following were distinguished: scoliotic postures: 1-9° and scoliosis: ≥10°. Results. There were 21 (75% with scoliotic posture and 7 (25% with scoliosis. The size of the thoracic kyphosis and lumbar lordosis was normal. Conclusions. Between the body postural variables in the sagittal plane and the scoliotic variables, both positive (direct proportional and negative (inversely proportional correlations occurred. In the selection of scoliosis treatment method, the size of the postural variables in the sagittal plane should be taken into account, and each patient’s case should be individually considered.

  18. Rat brain sagittal organotypic slice cultures as an ex vivo dopamine cell loss system.

    Science.gov (United States)

    McCaughey-Chapman, Amy; Connor, Bronwen

    2017-02-01

    Organotypic brain slice cultures are a useful tool to study neurological function as they provide a more complex, 3-dimensional system than standard 2-dimensional in vitro cell cultures. Building on a previously developed mouse brain slice culture protocol, we have developed a rat sagittal brain slice culture system as an ex vivo model of dopamine cell loss. We show that rat brain organotypic slice cultures remain viable for up to 6 weeks in culture. Using Fluoro-Gold axonal tracing, we demonstrate that the slice 3-dimensional cytoarchitecture is maintained over a 4 week culturing period, with particular focus on the nigrostriatal pathway. Treatment of the cultures with 6-hydroxydopamine and desipramine induces a progressive loss of Fluoro-Gold-positive nigral cells with a sustained loss of tyrosine hydroxylase-positive nigral cells. This recapitulates the pattern of dopaminergic degeneration observed in the rat partial 6-hydroxydopamine lesion model and, most importantly, the progressive pathology of Parkinson's disease. Our slice culture platform provides an advance over other systems, as we demonstrate for the first time 3-dimensional cytoarchitecture maintenance of rat nigrostriatal sagittal slices for up to 6 weeks. Our ex vivo organotypic slice culture system provides a long term cellular platform to model Parkinson's disease, allowing for the elucidation of mechanisms involved in dopaminergic neuron degeneration and the capability to study cellular integration and plasticity ex vivo. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Bilateral sagittal split osteotomy versus distraction osteogenesis for mandibular advancements

    NARCIS (Netherlands)

    Baas, E.M.

    2015-01-01

    The aim of this thesis was to compare the treatment modality of distraction osteogenesis (DO) with the gold standard for mandibular advancement surgery. In fact we compare distraction osteogenesis with the standard of care, which is a conventional bilateral sagittal split osteotomy as described by

  20. Correlation and Reliability of Cervical Sagittal Alignment Parameters between Lateral Cervical Radiograph and Lateral Whole-Body EOS Stereoradiograph

    Science.gov (United States)

    Singhatanadgige, Weerasak; Kang, Daniel G.; Luksanapruksa, Panya; Peters, Colleen; Riew, K. Daniel

    2015-01-01

    Study Design  Retrospective analysis. Objective  To evaluate the correlation and reliability of cervical sagittal alignment parameters obtained from lateral cervical radiographs (XRs) compared with lateral whole-body stereoradiographs (SRs). Methods  We evaluated adults with cervical deformity using both lateral XRs and lateral SRs obtained within 1 week of each other between 2010 and 2014. XR and SR images were measured by two independent spine surgeons using the following sagittal alignment parameters: C2–C7 sagittal Cobb angle (SCA), C2–C7 sagittal vertical axis (SVA), C1–C7 translational distance (C1–7), T1 slope (T1-S), neck tilt (NT), and thoracic inlet angle (TIA). Pearson correlation and paired t test were used for statistical analysis, with intra- and interrater reliability analyzed using intraclass correlation coefficient (ICC). Results  A total of 35 patients were included in the study. We found excellent intrarater reliability for all sagittal alignment parameters in both the XR and SR groups with ICC ranging from 0.799 to 0.994 for XR and 0.791 to 0.995 for SR. Interrater reliability was also excellent for all parameters except NT and TIA, which had fair reliability. We also found excellent correlations between XR and SR measurements for most sagittal alignment parameters; SCA, SVA, and C1–C7 had r > 0.90, and only NT had r < 0.70. There was a significant difference between groups, with SR having lower measurements compared with XR for both SVA (0.68 cm lower, p < 0.001) and C1–C7 (1.02 cm lower, p < 0.001). There were no differences between groups for SCA, T1-S, NT, and TIA. Conclusion  Whole-body stereoradiography appears to be a viable alternative for measuring cervical sagittal alignment parameters compared with standard radiography. XR and SR demonstrated excellent correlation for most sagittal alignment parameters except NT. However, SR had significantly lower average SVA and C1–C7 measurements than XR

  1. Overview of radiation effects research in photonics

    Science.gov (United States)

    Webb, Robert C.; Cohn, Lewis M.; Taylor, Edward W.; Greenwell, Roger A.

    1995-05-01

    A brief overview of ongoing radiation effects research in photonics is presented focusing on integrated optic and acousto-optic components. A short summary of radiation-induced effects in electro-optic modulators, detector arrays, and other photonic technologies is presented along with extensive references. The coordinated radiation effects studies among researchers within the Tri-Service Organizations and international experimental teams are beginning to demonstrate consistent measurements of radiation-induced effects in photonic components and confirming earlier reported data. This paper will present an overview of these coordinated investigations and focus on key research being conducted with the AFMC Phillips Laboratory, Naval Research Laboratory, Defence Nuclear Agency, NATO Nuclear Effects Task Group, and the Tri-Service Photonics Coordinating Committee.

  2. Simultaneous negative refraction and focusing of fundamental frequency and second-harmonic fields by two-dimensional photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jun [School of Physics, Beijing Institute of Technology and Beijing Key Laboratory of Fractional Signals and Systems, Beijing 100081 (China); College of Physics and Electronic Engineering, Henan Normal University, 453007 Xinxiang, Henan (China); Zhang, Xiangdong, E-mail: zhangxd@bit.edu.cn [School of Physics, Beijing Institute of Technology and Beijing Key Laboratory of Fractional Signals and Systems, Beijing 100081 (China)

    2015-09-28

    Simultaneous negative refraction for both the fundamental frequency (FF) and second-harmonic (SH) fields in two-dimensional nonlinear photonic crystals have been found through both the physical analysis and exact numerical simulation. By combining such a property with the phase-matching condition and strong second-order susceptibility, we have designed a SH lens to realize focusing for both the FF and SH fields at the same time. Good-quality non-near field images for both FF and SH fields have been observed. The physical mechanism for such SH focusing phenomena has been disclosed, which is different from the backward SH generation as has been pointed out in the previous investigations. In addition, the effect of absorption losses on the phenomena has also been discussed. Thus, potential applications of these phenomena to biphotonic microscopy technique are anticipated.

  3. Spinal sagittal imbalance in patients with lumbar disc herniation: its spinopelvic characteristics, strength changes of the spinal musculature and natural history after lumbar discectomy.

    Science.gov (United States)

    Liang, Chen; Sun, Jianmin; Cui, Xingang; Jiang, Zhensong; Zhang, Wen; Li, Tao

    2016-07-22

    Spinal sagittal imbalance is a widely acknowledged problem, but there is insufficient knowledge regarding its occurrence. In some patients with lumbar disc herniation (LDH), their symptom is similar to spinal sagittal imbalance. The aim of this study is to illustrate the spinopelvic sagittal characteristics and identity the role of spinal musculature in the mechanism of sagittal imbalance in patients with LDH. Twenty-five adults with spinal sagittal imbalance who initially came to our clinic for treatment of LDH, followed by posterior discectomy were reviewed. The horizontal distance between C7 plumb line-sagittal vertical axis (C7PL-SVA) greater than 5 cm anteriorly with forward bending posture is considered as spinal sagittal imbalance. Radiographic parameters including thoracic kyphotic angle (TK), lumbar lordotic angle (LL), pelvic tilting angle (PT), sacral slope angle (SS) and an electromyography(EMG) index 'the largest recruitment order' were recorded and compared. All patients restored coronal and sagittal balance immediately after lumbar discectomy. The mean C7PL-SVA and trunk shift value decreased from (11.6 ± 6.6 cm, and 2.9 ± 6.1 cm) preoperatively to (-0.5 ± 2.6 cm and 0.2 ± 0.5 cm) postoperatively, while preoperative LL and SS increased from (25.3° ± 14.0° and 25.6° ± 9.5°) to (42.4° ± 10.2° and 30.4° ± 8.7°) after surgery (P imbalance caused by LDH is one type of compensatory sagittal imbalance. Compensatory mechanism of spinal sagittal imbalance mainly includes a loss of lumbar lordosis, an increase of thoracic kyphosis and pelvis tilt. Spinal musculature plays an important role in spinal sagittal imbalance in patients with LDH.

  4. ?Lumbar Degenerative Kyphosis? Is Not Byword for Degenerative Sagittal Imbalance: Time to Replace a Misconception

    OpenAIRE

    Lee, Chang-Hyun; Chung, Chun Kee; Jang, Jee-Soo; Kim, Sung-Min; Chin, Dong-Kyu; Lee, Jung-Kil

    2017-01-01

    Lumbar degenerative kyphosis (LDK) is a subgroup of the flat-back syndrome and is most commonly caused by unique life styles, such as a prolonged crouched posture during agricultural work and performing activities of daily living on the floor. Unfortunately, LDK has been used as a byword for degenerative sagittal imbalance, and this sometimes causes confusion. The aim of this review was to evaluate the exact territory of LDK, and to introduce another appropriate term for degenerative sagittal...

  5. CORRELATION BETWEEN OBESITY, SAGITTAL BALANCE AND CLINICAL OUTCOME IN SPINAL FUSION

    Directory of Open Access Journals (Sweden)

    Marcel Machado da Motta

    2015-09-01

    Full Text Available Objective:To correlate obesity with radiographic parameters of spinal and spinopelvic balance in patients undergoing spinal arthrodesis, and to correlate obesity with clinical outcome of these patients.Methods:Observational retrospective study including patients who underwent spinal arthrodesis, with minimum follow-up period of three months. We measured waist circumference, as well as height and weight to calculate body mass index (BMI and obtained radiographs of the total column. The clinical parameters studied were pain by visual analog scale (VAS and the Oswestry questionnaire (ODI. Obesity correlated with radiographic parameters of the sagittal and spinopelvic balance and postoperative clinical parameters.Results:32 patients were analyzed. The higher the BMI, the greater the value of VAS found, but without statistical significance (p=0.83. There was also no correlation between BMI and the ODI questionnaire. Analyzing the abdominal circumference, there was no correlation between the VAS and ODI. There was no correlation between BMI or waist circumference and the radiographic parameters of global spinopelvic sagittal alignment. Regarding the postoperative results, there was no correlation between the mean BMI and waist circumference and the postoperative results for ODI and VAS (p=0.75 and p=0.7, respectively.Conclusions:The clinical outcomes of patients who undergone spinal fusion were not affected by the BMI and waist circumference. Also, there was no correlation between radiographic parameters of spinal and spinopelvic sagittal balance with obesity in patients previously treated with arthrodesis of the spine.

  6. Differences of Sagittal Lumbosacral Parameters between Patients with Lumbar Spondylolysis and Normal Adults.

    Science.gov (United States)

    Yin, Jin; Peng, Bao-Gan; Li, Yong-Chao; Zhang, Nai-Yang; Yang, Liang; Li, Duan-Ming

    2016-05-20

    Recent studies have suggested an association between elevated pelvic incidence (PI) and the development of lumbar spondylolysis. However, there is still lack of investigation for Han Chinese people concerning the normal range of spinopelvic parameters and relationship between abnormal sagittal parameters and lumbar diseases. The objective of the study was to investigate sagittal lumbosacral parameters of adult lumbar spondylolysis patients in Han Chinese population. A total of 52 adult patients with symptomatic lumbar spondylolysis treated in the General Hospital of Armed Police Force (Beijing, China) were identified as the spondylolysis group. All the 52 patients were divided into two subgroups, Subgroup A: 36 patients with simple lumbar spondylolysis, and Subgroup B: 16 patients with lumbar spondylolysis accompanying with mild lumbar spondylolisthesis (slip percentage spondylolysis group and the control group with independent-sample t- test. There were no statistically significant differences of all seven sagittal lumbosacral parameters between Subgroup A and Subgroup B. PI, PT, SS, and LL were higher (P spondylolysis group than those in the control group, but STA was lower (P spondylolysis group. Current study results suggest that increased PI and decreased STA may play important roles in the pathology of lumbar spondylolysis in Han Chinese population.

  7. Photon technology. Hard photon technology; Photon technology. Hard photon gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    Research results of hard photon technology have been summarized as a part of novel technology development highly utilizing the quantum nature of photon. Hard photon technology refers to photon beam technologies which use photon in the 0.1 to 200 nm wavelength region. Hard photon has not been used in industry due to the lack of suitable photon sources and optical devices. However, hard photon in this wavelength region is expected to bring about innovations in such areas as ultrafine processing and material synthesis due to its atom selective reaction, inner shell excitation reaction, and spatially high resolution. Then, technological themes and possibility have been surveyed. Although there are principle proposes and their verification of individual technologies for the technologies of hard photon generation, regulation and utilization, they are still far from the practical applications. For the photon source technology, the laser diode pumped driver laser technology, laser plasma photon source technology, synchrotron radiation photon source technology, and vacuum ultraviolet photon source technology are presented. For the optical device technology, the multi-layer film technology for beam mirrors and the non-spherical lens processing technology are introduced. Also are described the reduction lithography technology, hard photon excitation process, and methods of analysis and measurement. 430 refs., 165 figs., 23 tabs.

  8. Sagittal-lung CT measurements in the evaluation of asthma-COPD overlap syndrome: a distinctive phenotype from COPD alone.

    Science.gov (United States)

    Qu, Yanjuan; Cao, Yiyuan; Liao, Meiyan; Lu, Zhiyan

    2017-07-01

    This study aimed at investigating the capability of sagittal-lung computed tomography (CT) measurements in differentiating chronic obstructive pulmonary disease (COPD) and asthma-COPD overlap syndrome (ACOS). Clinical and high-resolution CT of 229 patients including 123 pure COPD patients and 106 ACOS patients were included. Sagittal-lung CT measurements in terms of bilateral lung height (LH), anterior-posterior lung diameter (APLD), diaphragm height (DH), and anterior sterno-diaphragmatic angle (ASDA), as well as inter-pulmonary septum length (IPSL) on axial images were measured both before and after bronchodilator (BD) administration. Comparisons of clinical characteristics and CT measurements between patient groups were performed. All pre-BD quantitative sagittal features measuring diaphragm flattening and hyperinflation were not significantly different between patients with COPD and patients with ACOS (P values all >0.05). Following BD administration, the ACOS patients exhibited lower left LH, bilateral APLD, and bilateral ASDA, but higher right DH, compared to pure COPD patients (P values all <0.05). Right LH, left DH and IPSL were not significantly different between patient groups. Besides, variations of all sagittal-lung CT measurements were significantly larger in patients with ACOS than in patients with pure COPD (P values all <0.001) and showed high performance in differentiating these two kinds of patient, with diagnostic sensitivities ranging from 76.4 to 97.2%, specificities ranging from 86.2 to 100.0%, and accuracies ranging from 80.9 to 90.7%. Sagittal-lung CT measurements allow for differentiating patients with ACOS from those with pure COPD. The ACOS patients had larger post-BD variations of sagittal-lung CT measurements than patients with pure COPD.

  9. System Engineering of Photonic Systems for Space Application

    Science.gov (United States)

    Watson, Michael D.; Pryor, Jonathan E.

    2014-01-01

    The application of photonics in space systems requires tight integration with the spacecraft systems to ensure accurate operation. This requires some detailed and specific system engineering to properly incorporate the photonics into the spacecraft architecture and to guide the spacecraft architecture in supporting the photonics devices. Recent research in product focused, elegant system engineering has led to a system approach which provides a robust approach to this integration. Focusing on the mission application and the integration of the spacecraft system physics incorporation of the photonics can be efficiently and effectively accomplished. This requires a clear understanding of the driving physics properties of the photonics device to ensure proper integration with no unintended consequences. The driving physics considerations in terms of optical performance will be identified for their use in system integration. Keywords: System Engineering, Optical Transfer Function, Optical Physics, Photonics, Image Jitter, Launch Vehicle, System Integration, Organizational Interaction

  10. Variations of cervical lordosis and head alignment after pedicle subtraction osteotomy surgery for sagittal imbalance.

    Science.gov (United States)

    Cecchinato, R; Langella, F; Bassani, R; Sansone, V; Lamartina, C; Berjano, P

    2014-10-01

    The variations of the cervical lordosis after correction of sagittal imbalance have been poorly studied. The aim of our study is to verify whether the cervical lordosis changes after surgery for sagittal imbalance. Thirty-nine patients were included in the study. Cervical, thoracic and lumbar spine, pelvic and lower-limb sagittal parameters were recorded. The cranial alignment was measured by the newly described Cranial Slope. The global cervical kyphosis (preop -43°, postop -31.5°) and the upper (preop -24.1°, postop -20.2°) and lower cervical kyphosis (preop -18.1°, postop -9.2°) were significantly reduced after surgical realignment of the trunk. A positive linear correlation was observed between the changes in T1 slope and the lower cervical lordosis, and between T1 slope and the global cervical alignment. The cervical lordosis is reduced by surgical correction of malalignment of the trunk, suggesting an adaptive role to maintain the head's neutral position.

  11. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Directory of Open Access Journals (Sweden)

    Yang Yang, Ying Fang, Xini Zhang, Junliang He, Weijie Fu

    2017-12-01

    Full Text Available The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively performed a weight-bearing dorsiflexion (WB-DF maneuver, drop jumps (DJs, and lay-up jumps (LJs. Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041 was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028 and power (p = 0.022 were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion–extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane.

  12. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Science.gov (United States)

    Yang, Yang; Fang, Ying; Zhang, Xini; He, Junliang; Fu, Weijie

    2017-12-01

    The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively) performed a weight-bearing dorsiflexion (WB-DF) maneuver, drop jumps (DJs), and lay-up jumps (LJs). Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041) was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028) and power (p = 0.022) were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion-extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane.

  13. A Comparison of Plain Radiography with Computer Tomography in Determining Coronal and Sagittal Alignments following Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Solayar GN

    2017-07-01

    Full Text Available INTRODUCTION: Optimal coronal and sagittal component positioning is important in achieving a successful outcome following total knee arthroplasty (TKA. Modalities to determine post-operative alignment include plain radiography and computer tomography (CT imaging. This study aims to determine the accuracy and reliability of plain radiographs in measuring coronal and sagittal alignment following TKA. MATERIALS AND METHODS: A prospective, consecutive study of 58 patients undergoing TKA was performed comparing alignment data from plain radiographs and CT imaging. Hip- knee-angle (HKA, sagittal femoral angle (SFA and sagittal tibial angle (STA measurements were taken by two observers from plain radiographs and compared with CT alignment. Intra- and inter-observer correlation was calculated for each measurement. RESULTS: Intra-observer correlation was excellent for HKA (r>0.89 with a mean difference of 0.95 and STA (r>0.8 compared to SFA (r=0.5. When comparing modalities (radiographs vs CT, HKA estimations for both observers showed the least maximum and mean differences while SFA observations were the least accurate. CONCLUSION: Radiographic estimation of HKA showed excellent intra- and inter-observer correlation and corresponds well with CT imaging. However, radiographic estimation of sagittal plane alignment was less reliably measured and correlated less with CT imaging. Plain radiography was found to be inferior to CT for estimation of biplanar prosthetic alignment following TKA.

  14. Sagittal spino-pelvic adjustment in severe Lenke 1 hypokyphotic adolescent idiopathic scoliosis patients.

    Science.gov (United States)

    Vidal, Christophe; Mazda, Keyvan; Ilharreborde, Brice

    2016-10-01

    The human standing position requires permanent reciprocal spino-pelvic adjustments to obtain a dynamic and economic posture. This study focuses on a hypokyphotic Lenke 1 adolescent idiopathic scoliosis (AIS) patients cohort and points out their particular lumbo-pelvic adaptive mechanisms to maintain a neutral sagittal balance. Preoperative retrospective analysis of prospectively collected data on a monocentric cohort of 455 AIS patients planned for corrective surgery. Radiological low-dose system coupled with a validated clinical routine software allowed to obtain data from eighty-four hypokyphotic [thoracic kyphosis (TK) <20°] Lenke 1 patients and were separately analyzed. Bilateral Student and one-way ANOVAs were conducted for statistical analysis. Mean Cobb angle was 46.3° (±7.2), TK was 11° (±7.1), sagittal vertical axis (SVA) was -10.1 mm (±30.9), pelvic incidence (PI) was 55.7° (±12.9). Fifty percents of patients were posteriorly imbalanced. Among them, patients with a low PI used an anteversion of their pelvis [indicated by a high pelvic tilt (PT) angle] but were not able to increase their lumbar lordosis (LL) to minimize the posterior spinal shift. Hypokyphotic Lenke 1 AIS patients use lumbo-pelvic compensatory mechanisms to maintain their global balance with a poor effectiveness. Subjects with a low PI have a restricted range of LL adaptation. Attention should be paid during surgical planning not to overcorrect lordosis in the instrumented levels in case of non-selective fusion, that may induce posterior shift of the fusion mass and expose to junctional syndromes and poor functional outcomes in this particular patients.

  15. Optimization of a photon rejecter to separate electronic noise in a photon-counting detector

    International Nuclear Information System (INIS)

    Cho, Hyo-Min; Choi, Yu-Na; Lee, Seung-Wan; Lee, Young-Jin; Ryu, Hyun-Ju; Kim, Hee-Joung

    2012-01-01

    Photon-counting-based X-ray imaging technology provides the capability to count individual photons and to characterize photon energies. The cadmium telluride (CdTe)-based photon-counting detector is limited in capability, however, under a high X-ray flux. A photon rejecter composed of aluminum, for example, can reduce this limitation by modulating the incident number of photons. In addition to this function, the optimal photon rejecter can separate electronic noise, which degrades image quality. The aim of this work was to optimize a photon rejecter for high-quality image acquisition by removing electronic noise from the actual pulse signal. The images and spectra were acquired using a micro-focus X-ray source with a CdTe-based photon-counting detector. We acquired data with various types of photon-rejecter materials composed of aluminum (Al) and iodine at three different tube voltages (50, 70, and 90 kVp). A phantom composed of high-atomic-number materials was imaged to evaluate the efficiency of the photon rejecter. Photon rejecters composed of 1-mm Al, 10-mm Al, and a combination of 10-mm Al and iodine provided optimum capability at 50, 70, and 90 kVp, respectively. Each optimal combination of photon-rejecter material and voltage effectively separated electronic noise from the actual pulse signal and gave the highest contrast-to-noise ratio for materials on the image. These optimized types of photon rejecters can effectively discriminate electronic noise and improve image quality at different tube voltages.

  16. Comparison of prostate contours between conventional stepping transverse imaging and Twister-based sagittal imaging in permanent interstitial prostate brachytherapy.

    Science.gov (United States)

    Kawakami, Shogo; Ishiyama, Hiromichi; Satoh, Takefumi; Tsumura, Hideyasu; Sekiguchi, Akane; Takenaka, Kouji; Tabata, Ken-Ichi; Iwamura, Masatsugu; Hayakawa, Kazushige

    2017-08-01

    To compare prostate contours on conventional stepping transverse image acquisitions with those on twister-based sagittal image acquisitions. Twenty prostate cancer patients who were planned to have permanent interstitial prostate brachytherapy were prospectively accrued. A transrectal ultrasonography probe was inserted, with the patient in lithotomy position. Transverse images were obtained with stepping movement of the transverse transducer. In the same patient, sagittal images were also obtained through rotation of the sagittal transducer using the "Twister" mode. The differences of prostate size among the two types of image acquisitions were compared. The relationships among the difference of the two types of image acquisitions, dose-volume histogram (DVH) parameters on the post-implant computed tomography (CT) analysis, as well as other factors were analyzed. The sagittal image acquisitions showed a larger prostate size compared to the transverse image acquisitions especially in the anterior-posterior (AP) direction ( p transverse image acquisitions was correlated to DVH parameters such as D 90 ( R = 0.518, p = 0.019), and V 100 ( R = 0.598, p = 0.005). There were small but significant differences in the prostate contours between the transverse and the sagittal planning image acquisitions. Furthermore, our study suggested that the differences between the two types of image acquisitions might correlated to dosimetric results on CT analysis.

  17. Three-dimensional photon radiotherapy planning for laryngeal and hypopharyngeal tumours

    International Nuclear Information System (INIS)

    Esik, O.; Schlegel, W.; Doll, J.; Nemeth, G.; Lorenz, W.J.; Weil Emil Korhaz-Rendeloeintezet, Budapest; Deutsches Krebsforschungszentrum, Heidelberg

    1990-01-01

    Three-dimensional absorbed dose distributions have been computed for high-energy photon radiation therapy of laryngeal and hypopharyngeal cancers, using a coaxial pair of opposing lateral beams in fixed positions. Treatment plans obtained under various conditions of irradiation are analyzed and compared for a cobalt-60 gamma unit (GAMMATRON S80, Siemens), photon beams from a 6 MV (CLINAC 1800, VARIAN), an 8 MV (SATURNE, CGR) and a 15 MV (MEVATRON 77, Siemens) linear accelerator. Using open fields a somewhat non-uniform and partly insufficient dose in target volume of interest is obtained with all treatment units if sufficient protection of the spinal cord is provided. The X-ray plans are somewhat superior to the cobalt-60 ones. Depending on the quantum energy and wedge isodose angle, wedging only slightly improves or sometimes moderately decreases the homogeneity of the dose in the target volume. According to these small and/or controversial effects of wedges their application seems unnecessary and/or non-convenient. Simulations show that extreme care is needed in positioning the isocentre: An accuracy of ±3 mm is required in the median sagittal plane. (orig.)

  18. Photon Propagation through Linearly Active Dimers

    Directory of Open Access Journals (Sweden)

    José Delfino Huerta Morales

    2017-06-01

    Full Text Available We provide an analytic propagator for non-Hermitian dimers showing linear gain or losses in the quantum regime. In particular, we focus on experimentally feasible realizations of the PT -symmetric dimer and provide their mean photon number and second order two-point correlation. We study the propagation of vacuum, single photon spatially-separable, and two-photon spatially-entangled states. We show that each configuration produces a particular signature that might signal their possible uses as photon switches, semi-classical intensity-tunable sources, or spatially entangled sources to mention a few possible applications.

  19. Sagittal synostosis: II. Cranial morphology and growth after the modified pi-plasty

    DEFF Research Database (Denmark)

    Guimaraes-Ferreira, J.; Gewalli, F.; David, L.

    2006-01-01

    The aim of this study was to characterise the postoperative cranial growth and morphology after a modified pi-plasty for sagittal synostosis. The shape of the skull of 82 patients with isolated premature synostosis of the sagittal suture ( SS group) operated on with a modified pi-plasty was studied...... developed by Kreiborg, which included the digitisation of 89 landmarks of the calvaria, cranial base, and orbit ( 43 in the lateral and 46 in the frontal projections), the production of mean shape plots for each group, and the intergroup comparison of a series of 78 variables ( linear distance between...... selected landmarks, and angles defined by groups of three landmarks). Paired and unpaired t tests were used to assess the differences between the variables studied. These were accepted as significant for values of p...

  20. The association between whole body sagittal balance and risk of falls among elderly patients seeking treatment for back pain.

    Science.gov (United States)

    Kim, J; Hwang, J Y; Oh, J K; Park, M S; Kim, S W; Chang, H; Kim, T-H

    2017-05-01

    The objective of this study was to assess the association between whole body sagittal balance and risk of falls in elderly patients who have sought treatment for back pain. Balanced spinal sagittal alignment is known to be important for the prevention of falls. However, spinal sagittal imbalance can be markedly compensated by the lower extremities, and whole body sagittal balance including the lower extremities should be assessed to evaluate actual imbalances related to falls. Patients over 70 years old who visited an outpatient clinic for back pain treatment and underwent a standing whole-body radiograph were enrolled. Falls were prospectively assessed for 12 months using a monthly fall diary, and patients were divided into fallers and non-fallers according to the history of falls. Radiological parameters from whole-body radiographs and clinical data were compared between the two groups. A total of 144 patients (120 female patients and 24 male patients) completed a 12-month follow-up for assessing falls. A total of 31 patients (21.5%) reported at least one fall within the 12-month follow-up. In univariate logistic regression analysis, the risk of falls was significantly increased in older patients and those with more medical comorbidities, decreased lumbar lordosis, increased sagittal vertical axis, and increased horizontal distance between the C7 plumb line and the centre of the ankle (C7A). Increased C7A was significantly associated with increased risk of falls even after multivariate adjustment. Whole body sagittal balance, measured by the horizontal distance between the C7 plumb line and the centre of the ankle, was significantly associated with risk of falls among elderly patients with back pain. Cite this article : J. Kim, J. Y. Hwang, J. K. Oh, M. S. Park, S. W. Kim, H. Chang, T-H. Kim. The association between whole body sagittal balance and risk of falls among elderly patients seeking treatment for back pain. Bone Joint Res 2017;6:-344. DOI: 10

  1. Silicon photomultiplier as a detector of Cherenkov photons

    International Nuclear Information System (INIS)

    Korpar, S.; Dolenec, R.; Hara, K.; Iijima, T.; Krizan, P.; Mazuka, Y.; Pestotnik, R.; Stanovnik, A.; Yamaoka, M.

    2008-01-01

    A novel photon detector-i.e. the silicon photomultiplier-whose main advantage over conventional photomultiplier tubes is the operation in high magnetic fields, has been tested as a photon detector in a proximity focusing RICH with aerogel radiator. This type of RICH counter is proposed for the upgrade of the Belle detector at the KEK B-factory. Recently produced silicon photomultipliers show less noise and have larger size, which are important issues for a large area photon detector. We measured the single photon pulse height distribution, the timing resolution and the position sensitivity for different silicon photomultipliers (Hamamatsu MPPC HC025, HC050, and HC100). The silicon photomultipliers were then used to detect Cherenkov photons emitted by cosmic ray particles in a proximity focusing aerogel RICH. Various light guides were investigated in order to increase the detection efficiency

  2. Fracture of fusion mass after hardware removal in patients with high sagittal imbalance.

    Science.gov (United States)

    Sedney, Cara L; Daffner, Scott D; Stefanko, Jared J; Abdelfattah, Hesham; Emery, Sanford E; France, John C

    2016-04-01

    As spinal fusions become more common and more complex, so do the sequelae of these procedures, some of which remain poorly understood. The authors report on a series of patients who underwent removal of hardware after CT-proven solid fusion, confirmed by intraoperative findings. These patients later developed a spontaneous fracture of the fusion mass that was not associated with trauma. A series of such patients has not previously been described in the literature. An unfunded, retrospective review of the surgical logs of 3 fellowship-trained spine surgeons yielded 7 patients who suffered a fracture of a fusion mass after hardware removal. Adult patients from the West Virginia University Department of Orthopaedics who underwent hardware removal in the setting of adjacent-segment disease (ASD), and subsequently experienced fracture of the fusion mass through the uninstrumented segment, were studied. The medical records and radiological studies of these patients were examined for patient demographics and comorbidities, initial indication for surgery, total number of surgeries, timeline of fracture occurrence, risk factors for fracture, as well as sagittal imbalance. All 7 patients underwent hardware removal in conjunction with an extension of fusion for ASD. All had CT-proven solid fusion of their previously fused segments, which was confirmed intraoperatively. All patients had previously undergone multiple operations for a variety of indications, 4 patients were smokers, and 3 patients had osteoporosis. Spontaneous fracture of the fusion mass occurred in all patients and was not due to trauma. These fractures occurred 4 months to 4 years after hardware removal. All patients had significant sagittal imbalance of 13-15 cm. The fracture level was L-5 in 6 of the 7 patients, which was the first uninstrumented level caudal to the newly placed hardware in all 6 of these patients. Six patients underwent surgery due to this fracture. The authors present a case series of 7

  3. Bulky scalp metastasis and superior sagittal sinus thrombosis from a cervical adenocarcinoma: an unusual case

    International Nuclear Information System (INIS)

    Abhishek, A.; Ouseph, M. M.; Sharma, M.; Sharma, P.; Kamal, V.

    2008-01-01

    Distant cutaneous metastases from cervical malignancies are uncommon, with scalp metastases being exceptional events. We present the case of a 53-year-old postmenopausal lady with adenocarcinoma of the uterine cervix that metastasized to the scalp with superior sagittal sinus thrombosis 8 months after diagnosis. In contrast to the seven prior cases of scalp metastases of cervical squamous cell carcinoma reported in published reports, ours is the first documentation of such an occurrence in cervical adenocarcinoma. Superior sagittal sinus thrombosis has not been reported with this tumour in the past.

  4. Evolution of the postoperative sagittal spinal profile in early-onset scoliosis: is there a difference between rib-based and spine-based growth-friendly instrumentation?

    Science.gov (United States)

    Chen, Zhonghui; Li, Song; Qiu, Yong; Zhu, Zezhang; Chen, Xi; Xu, Liang; Sun, Xu

    2017-12-01

    OBJECTIVE Although the vertical expandable prosthetic titanium rib (VEPTR) and growing rod instrumentation (GRI) encourage spinal growth via regular lengthening, they can create different results because of their different fixation patterns and mechanisms in correcting scoliosis. Previous studies have focused comparisons on coronal plane deformity with minimal attention to the sagittal profile. In this retrospective study, the authors aimed to compare the evolution of the sagittal spinal profile in early-onset scoliosis (EOS) treated with VEPTR versus GRI. METHODS The data for 11 patients with VEPTR and 22 with GRI were reviewed. All patients had more than 2 years' follow-up with more than 2 lengthening procedures. Radiographic measurements were performed before and after the index surgery and at the latest follow-up. The complications in both groups were recorded. RESULTS Patients in both groups had similar diagnoses, age at the index surgery, and number of lengthening procedures. The changes in the major coronal Cobb angle and T1-S1 spinal height were not significantly different between the 2 groups. Compared with the GRI group, the VEPTR group had less correction in thoracic kyphosis (23% ± 12% vs 44% ± 16%, p GRI: 8° ± 5°, p = 0.569), the incidence of proximal junctional kyphosis was relatively lower in the VEPTR group (VEPTR: 18.2% vs GRI: 22.7%). No significant changes in the spinopelvic parameters were observed, while the sagittal vertical axis showed a tendency toward a neutral position in both groups. The overall complication rate was higher in the VEPTR group than in the GRI group (72.7% vs 54.5%). CONCLUSIONS The VEPTR had coronal correction and spinal growth results similar to those with GRI. In the sagittal plane, however, the VEPTR was not comparable to the GRI in controlling thoracic kyphosis. Thus, for hyperkyphotic EOS patients, GRI is recommended over VEPTR.

  5. Comparative Study of Skeletal Stability between Postoperative Skeletal Intermaxillary Fixation and No Skeletal Fixation after Bilateral Sagittal Split Ramus Osteotomy

    DEFF Research Database (Denmark)

    Hartlev, Jens; Godtfredsen, Erik; Andersen, Niels Trolle

    2014-01-01

    OBJECTIVES: The purpose of the present study was to evaluate skeletal stability after mandibular advancement with bilateral sagittal split osteotomy. MATERIAL AND METHODS: Twenty-six patients underwent single-jaw bilateral sagittal split osteotomy (BSSO) to correct skeletal Class II malocclusion....

  6. Enhanced Etching, Surface Damage Recovery, and Submicron Patterning of Hybrid Perovskites using a Chemically Gas-Assisted Focused-Ion Beam for Subwavelength Grating Photonic Applications

    KAUST Repository

    Alias, Mohd Sharizal

    2015-12-22

    The high optical gain and absorption of organic–inorganic hybrid perovskites have attracted attention for photonic device applications. However, owing to the sensitivity of organic moieties to solvents and temperature, device processing is challenging, particularly for patterning. Here, we report the direct patterning of perovskites using chemically gas-assisted focused-ion beam (GAFIB) etching with XeF2 and I2 precursors. We demonstrate etching enhancement in addition to controllability and marginal surface damage compared to focused-ion beam (FIB) etching without precursors. Utilizing the GAFIB etching, we fabricated a uniform and periodic submicron perovskite subwavelength grating (SWG) absorber with broadband absorption and nanoscale precision. Our results demonstrate the use of FIB as a submicron patterning tool and a means of providing surface treatment (after FIB patterning to minimize optical loss) for perovskite photonic nanostructures. The SWG absorber can be patterned on perovskite solar cells to enhance the device efficiency through increasing light trapping and absorption.

  7. Effects of four-wave mixing on four-photon resonance excitation and ionization in the presence of a three-photon intermediate state resonance enhancement

    International Nuclear Information System (INIS)

    Payne, M.G.; Miller, J.C.; Hart, R.C.; Garrett, W.R.

    1991-01-01

    We consider effects which occur when four-wave sum frequency generation and multiphoton ionization are induced by lasers tuned near a three-photon resonance and simultaneously near or at a dipole allowed four-photon resonance. In studies with unfocused laser beams, if the phase mismatch of the generated four-wave-mixing field is large and the related two-photon resonance for the absorption of a four-wave-mixing photon and a laser photon results in strong absorption of the four-wave-mixing field, a coherent cancellation occurs between the pumping of the resonance by two- and four-photon processes. This interference effect occurs when the first laser is tuned on either side of the three-photon resonance and |Δk rL |much-gt 1, where Δk r is the mismatch and L is the length of the path of the laser beams in the gas. With focused laser beams large differences occur between ionization with unidirectional beams and with counterpropagating laser beams when |Δk rb |much-gt 1, where b is the confocal parameter of the focused laser beams. Strong absorption of the four-wave-mixing field is shown not to be necessary for strong destructive interference with focused laser beams when the phase mismatch is large. This work also suggests an explanation for earlier experiments where the presence of a four-photon resonance enabled the generation of third-harmonic light in a positively dispersive wavelength region. We argue that this process can occur when the laser used to achieve the four-photon resonance is focused on the small z (z is the coordinate in the direction of propagation) side of the focal point of the laser responsible for the third-harmonic generation

  8. Dorsal free graft urethroplasty for urethral stricture by ventral sagittal urethrotomy approach.

    Science.gov (United States)

    Asopa, H S; Garg, M; Singhal, G G; Singh, L; Asopa, J; Nischal, A

    2001-11-01

    To explore the feasibility of applying a dorsal free graft to treat urethral stricture by the ventral sagittal urethrotomy approach without mobilizing the urethra. Twelve patients with long or multiple strictures of the anterior urethra were treated by a dorsal free full-thickness preputial or buccal mucosa graft. The urethra was not separated from the corporal bodies and was opened in the midline over the stricture. The floor of the urethra was incised, and an elliptical raw area was created over the tunica on which a free full-thickness graft of preputial or buccal mucosa was secured. The urethra was retubularized in one stage. After a follow-up of 8 to 40 months, one recurrence developed and required dilation. The ventral sagittal urethrotomy approach for dorsal free graft urethroplasty is not only feasible and successful, but is easy to perform.

  9. WAVELET ANALYSIS AND NEURAL NETWORK CLASSIFIERS TO DETECT MID-SAGITTAL SECTIONS FOR NUCHAL TRANSLUCENCY MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Giuseppa Sciortino

    2016-04-01

    Full Text Available We propose a methodology to support the physician in the automatic identification of mid-sagittal sections of the fetus in ultrasound videos acquired during the first trimester of pregnancy. A good mid-sagittal section is a key requirement to make the correct measurement of nuchal translucency which is one of the main marker for screening of chromosomal defects such as trisomy 13, 18 and 21. NT measurement is beyond the scope of this article. The proposed methodology is mainly based on wavelet analysis and neural network classifiers to detect the jawbone and on radial symmetry analysis to detect the choroid plexus. Those steps allow to identify the frames which represent correct mid-sagittal sections to be processed. The performance of the proposed methodology was analyzed on 3000 random frames uniformly extracted from 10 real clinical ultrasound videos. With respect to a ground-truth provided by an expert physician, we obtained a true positive, a true negative and a balanced accuracy equal to 87.26%, 94.98% and 91.12% respectively.

  10. CORRELATION BETWEEN CERVICAL SAGITTAL ALIGNMENT AND FUNCTIONAL CAPACITY IN CERVICAL SPONDYLOSIS

    Directory of Open Access Journals (Sweden)

    Marcel Machado da Motta

    Full Text Available ABSTRACT Objective: To correlate the radiographic parameters of sagittal cervical alignment with quality of life and functional capacity in patients with cervical spondylosis under conservative treatment. Methods: This is an observational and prospective study in patients with cervical spondylosis under conservative treatment and without indication for surgery. The 52 patients included were divided into three groups: axial pain, radiculopathy, and cervical myelopathy. The radiographic parameters considered were cervical lordosis (CL, cervical sagittal vertical axis (CSVA, T1 slope (TS and the discrepancy between TS and CL (TS-CL. Quality of life and functional capacity were evaluated by the Neck Disability Index (NDI questionnaire. Pain was assessed by the Visual Analogue Scale (VAS. The correlation between the radiographic parameters and the clinical scores was evaluated by the Pearson correlations coefficient. Results: There was no difference in cervical radiographic parameters between the three groups. In the total of the sample, the mean value of the CSVA was 17.8o (±8.3o, CL, 22.4° (± 8.8°; TS, 29.3° (±6.6°, and TS-CL, 7.0° (±7.4°. Significant inverse correlation (r= -0.3, p=0.039 was observed between NDI and CL, but there was no significant correlation between CL and VAS. CSVA (p=0.541, TS (p=0.287 and TS-CL (p=0.287 had no significantly correlated with NDI or VAS. Conclusion: Considering patients with cervical spondylosis not candidates for surgery, the only sagittal parameter that correlated with functional capacity was LC. In these patients, the correlation between cervical alignment and quality of life needs to be better characterized.

  11. [Evaluation of the clinical results of non-surgical treatment for pediatric sagittal fracture of mandibular condyle].

    Science.gov (United States)

    Liu, Chang-kui; Tan, Xin-ying; Xu, Juan; Liu, Hua-wei; Liu, San-xia; Hu, Min

    2013-11-01

    To investigate the clinical results of occlusal splint in the treatment of sagittal fracture of mandibular condyle (SFMC) in children. Thirty-nine patients (48 condyles)aged 3-8 years with sagittal fracture of mandibular condyle were included in this study. All the patients were treated by occlusal splint.Slight open occlusion was maintained by occlusal splint for 3-6 months. Clinical and radiological examination was performed six mouths and every year after treatment. Good mandibular function was observed in 39 patients. Maximal mouth opening over 35 mm was achieved at 6 months. But 11 of the 39 patients presented with deviation on mouth opening at 6 months. The radiology showed an complete remodeling in 32 condyles (28 patients) and partial remodeling in 16 condyles (11 patients). Poor remodelling was not observed in any patients. Good clinical results can be obtained by using occlusal splint in the treatment of pediatric sagittal fracture of mandibular condyle.

  12. A rare complication in a child undergoing chemotherapy for acute lymphoblastic leukemia: Superior sagittal sinus thrombosis

    Directory of Open Access Journals (Sweden)

    Ting-Yao Wang

    2011-04-01

    Full Text Available We report the case of a 4-year-old boy with acute lymphoblastic leukemia in high-risk group who suffered from generalized tonic-colonic seizure evolving into status epilepticus, and subsequent left hemiparesis during his first reinduction chemotherapy, consisting of dexamethasone, vincristine, l-asparaginase, and epirubicin. Superior sagittal sinus and cerebral venous thrombosis, predominantly in right side, were proved by brain magnetic resonance imaging. After aggressive treatment with low-molecular weight heparin (LMWH, left hemiparesis improved in 1 week. And he was fully ambulatory 3 weeks later. The second cycle of reinduction chemotherapy was conducted smoothly with the concomitant use of LMWH. This case illustrates the strong correlation of the rare thrombotic complication, superior sagittal sinus thrombosis, and hypercoagulable status secondary to combination use of l-asparaginase and corticosteroid. Early and vigilant recognition of superior sagittal sinus thrombosis and prompt anticoagulation with LMWH may prevent further neurological damage.

  13. A comparison of economy and sagittal plane trunk movements among back-, back/front- and head-loading.

    Science.gov (United States)

    Hudson, Sean; Cooke, Carlton; Davies, Simeon; West, Sacha; Gamieldien, Raeeq; Low, Chris; Lloyd, Ray

    2018-05-14

    It has been suggested that freedom of movement in the trunk could influence load carriage economy. This study aimed to compare the economy and sagittal plane trunk movements associated with three load carriage methods that constrain posture differently. Eighteen females walked at 3 km.h -1 with loads of 0, 3, 6, 9, 12, 15 and 20 kg carried on the back, back/front and head. Load carriage economy was assessed using the Extra Load Index (ELI). Change in sagittal plane trunk forward lean and trunk angle excursion from unloaded to loaded walking were assessed. Results show no difference in economy between methods (p = 0.483), despite differences in the change in trunk forward lean (p = 0.001) and trunk angle excursion (p = 0.021) from unloaded to loaded walking. We conclude that economy is not different among the three methods of load carriage, despite significant differences in sagittal plane trunk movements.

  14. Risk factors affecting somatosensory function after sagittal split osteotomy

    DEFF Research Database (Denmark)

    Thygesen, Torben Henrik; Jensen, Allan Bardow; Helleberg, M

    2008-01-01

    Purpose The aim of this study was to evaluate potential individual and intraoperative risk factors associated with bilateral sagittal split osteotomy (BSSO) and to correlate the findings with postoperative changes in somatosensory function. Patients and Methods A total of 18 men and 29 women (mean...... and free dissection of the inferior alveolar nerve during BSSO increased self-reported changes in lower lip sensation and lower lip tactile threshold after BSSO (P discrimination (P

  15. Progress in neuromorphic photonics

    Science.gov (United States)

    Ferreira de Lima, Thomas; Shastri, Bhavin J.; Tait, Alexander N.; Nahmias, Mitchell A.; Prucnal, Paul R.

    2017-03-01

    As society's appetite for information continues to grow, so does our need to process this information with increasing speed and versatility. Many believe that the one-size-fits-all solution of digital electronics is becoming a limiting factor in certain areas such as data links, cognitive radio, and ultrafast control. Analog photonic devices have found relatively simple signal processing niches where electronics can no longer provide sufficient speed and reconfigurability. Recently, the landscape for commercially manufacturable photonic chips has been changing rapidly and now promises to achieve economies of scale previously enjoyed solely by microelectronics. By bridging the mathematical prowess of artificial neural networks to the underlying physics of optoelectronic devices, neuromorphic photonics could breach new domains of information processing demanding significant complexity, low cost, and unmatched speed. In this article, we review the progress in neuromorphic photonics, focusing on photonic integrated devices. The challenges and design rules for optoelectronic instantiation of artificial neurons are presented. The proposed photonic architecture revolves around the processing network node composed of two parts: a nonlinear element and a network interface. We then survey excitable lasers in the recent literature as candidates for the nonlinear node and microring-resonator weight banks as the network interface. Finally, we compare metrics between neuromorphic electronics and neuromorphic photonics and discuss potential applications.

  16. Normal anatomy of the female pelvis in axial, coronal, and sagittal planes demonstrated with reformatted CT

    International Nuclear Information System (INIS)

    Constant, O.C.; Cooke, J.C.; Parsons, C.A.

    1987-01-01

    Axial CT is used in assessing gynecologic malignancies. Accurate delineation of local tumor extent in carcinoma of the cervix is important in initial staging and in planning subsequent management. A modified scanning technique produces reformatted coronal and sagittal images, which demonstrate additional valuable information about the cardinal ligaments, parametria, ureters, boundaries between the cervix, bladder, and rectum, and extension to vagina and uterus. This information is illustrated by representative axial, coronal, and sagittal scans. Familiarity with normal appearances is essential to allow correct interpretation of pathology

  17. Ipsilateral wrist-ankle movements in the sagittal plane encoded in extrinsic reference frame.

    Science.gov (United States)

    Muraoka, Tetsuro; Ishida, Yuki; Obu, Takashi; Crawshaw, Larry; Kanosue, Kazuyuki

    2013-04-01

    When performing oscillatory movements of two joints in the sagittal plane, there is a directional constraint for performing such movements. Previous studies could not distinguish whether the directional constraint reflected movement direction encoded in the extrinsic (outside the body) reference frame or in the intrinsic (the participants' torso/head) reference frame since participants performed coordinated movements in a sitting position where the torso/head was stationary relative to the external world. In order to discern the reference frame in the present study, participants performed paced oscillatory movements of the ipsilateral wrist and ankle in the sagittal plane in a standing position so that the torso/head moved relative to the external world. The coordinated movements were performed in one of two modes of coordination, moving the hand upward concomitant with either ankle plantarflexion or ankle dorsiflexion. The same directional mode relative to extrinsic space was more stable and accurate as compared with the opposite directional mode. When forearm position was changed from the pronated position to the supinated position, similar results were obtained, indicating that the results were independent of a particular coupling of muscles. These findings suggest that the directional constraint on ipsilateral joints movements in the sagittal plane reflects movement direction encoded in the extrinsic reference frame. Copyright © 2013 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  18. Is Postoperative Intensive Care Unit Care Necessary following Cranial Vault Remodeling for Sagittal Synostosis?

    Science.gov (United States)

    Wolfswinkel, Erik M; Howell, Lori K; Fahradyan, Artur; Azadgoli, Beina; McComb, J Gordon; Urata, Mark M

    2017-12-01

    Of U.S. craniofacial and neurosurgeons, 94 percent routinely admit patients to the intensive care unit following cranial vault remodeling for correction of sagittal synostosis. This study aims to examine the outcomes and cost of direct ward admission following primary cranial vault remodeling for sagittal synostosis. An institutional review board-approved retrospective review was undertaken of the records of all patients who underwent primary cranial vault remodeling for isolated sagittal craniosynostosis from 2009 to 2015 at a single pediatric hospital. Patient demographics, perioperative course, and outcomes were recorded. One hundred ten patients met inclusion criteria with absence of other major medical problems. Average age at operation was 6.7 months, with a mean follow-up of 19.8 months. Ninety-eight patients (89 percent) were admitted to a general ward for postoperative care, whereas the remaining 12 (11 percent) were admitted to the intensive care unit for preoperative or perioperative concerns. Among ward-admitted patients, there were four (3.6 percent) minor complications; however, there were no major adverse events, with none necessitating intensive care unit transfers from the ward and no mortalities. Average hospital stay was 3.7 days. The institution's financial difference in cost of intensive care unit stay versus ward bed was $5520 on average per bed per day. Omitting just one intensive care unit postoperative day stay for this patient cohort would reduce projected health care costs by a total of $540,960 for the study period. Despite the common practice of postoperative admission to the intensive care unit following cranial vault remodeling for sagittal craniosynostosis, the authors suggest that postoperative care be considered on an individual basis, with only a small percentage requiring a higher level of care. Therapeutic, III.

  19. Cost, operation and hospitalization times in distraction osteogenesis versus sagittal split osteotomy

    NARCIS (Netherlands)

    van Strijen, P. J.; Breuning, K. H.; Becking, A. G.; Perdijk, F. B. T.; Tuinzing, D. B.

    2003-01-01

    Distraction osteogenesis in 'common' surgical orthodontics is mentioned as an alternative for conventional sagittal split osteotomy. After a 'learning curve' in the surgical skills of distraction, the two techniques can be compared concerning time and cost aspects. Forty-seven patients (male n=28,

  20. Line broadening by focusing

    International Nuclear Information System (INIS)

    Brito, A.L. de; Jabs, A.

    1983-01-01

    It is pointed out that the spectral width of a quasi-monochromatic light beam broadens when the beam is focused. A quantitative formula for this broadening is derived from classical wave theory. The effect is shown to explain some experiments on laser beams done by E. Panarella which that author has explained under the ad-hoc hypothesis that the frequency of the photons changes along with the intensity of the light beam. The line broadening by focusing might also contribute to gas ionization by incident light when the ionization potential is well above the mean photon energy. Some remarks are made on some direct applications of the Heisenberg relations in comparison with our treatment. (Author) [pt

  1. A Review Of Referral Patterns For Sagittal Synostosis In Ireland: 2008-2013

    LENUS (Irish Health Repository)

    Berney, M J

    2018-01-01

    Sagittal synostosis (SS) is the commonest form of craniosynostosis. Children with sagittal synostosis in Ireland are treated in the National Paediatric Craniofacial Centre (NPCC) in Temple Street Children’s University Hospital. This retrospective study analysed the correlation between referral patterns to the unit and age at operation. The notes of 81 patients referred over a 5 year period (April 2008 – April 2013) to the NPCC with non-syndromic SS were reviewed and demographics and referral information were recorded. Of 81 patients reviewed, 60 (74%) were referred before 6 months of age, while 21 (26%) had late referrals. Neonatologists referred 100% of infants before 6 months, paediatricians referred 71%, and GPs 64%. Later referral was associated with a more complex referral pathway, including multiple-steps of referral and unnecessary investigations. Improved clinician knowledge and emphasis on the importance of early referral may lead to a reduction in late referrals.

  2. Computational Modeling of Photonic Crystal Microcavity Single-Photon Emitters

    Science.gov (United States)

    Saulnier, Nicole A.

    Conventional cryptography is based on algorithms that are mathematically complex and difficult to solve, such as factoring large numbers. The advent of a quantum computer would render these schemes useless. As scientists work to develop a quantum computer, cryptographers are developing new schemes for unconditionally secure cryptography. Quantum key distribution has emerged as one of the potential replacements of classical cryptography. It relics on the fact that measurement of a quantum bit changes the state of the bit and undetected eavesdropping is impossible. Single polarized photons can be used as the quantum bits, such that a quantum system would in some ways mirror the classical communication scheme. The quantum key distribution system would include components that create, transmit and detect single polarized photons. The focus of this work is on the development of an efficient single-photon source. This source is comprised of a single quantum dot inside of a photonic crystal microcavity. To better understand the physics behind the device, a computational model is developed. The model uses Finite-Difference Time-Domain methods to analyze the electromagnetic field distribution in photonic crystal microcavities. It uses an 8-band k · p perturbation theory to compute the energy band structure of the epitaxially grown quantum dots. We discuss a method that combines the results of these two calculations for determining the spontaneous emission lifetime of a quantum dot in bulk material or in a microcavity. The computational models developed in this thesis are used to identify and characterize microcavities for potential use in a single-photon source. The computational tools developed are also used to investigate novel photonic crystal microcavities that incorporate 1D distributed Bragg reflectors for vertical confinement. It is found that the spontaneous emission enhancement in the quasi-3D cavities can be significantly greater than in traditional suspended slab

  3. Photon-photon scattering at the high-intensity frontier

    Science.gov (United States)

    Gies, Holger; Karbstein, Felix; Kohlfürst, Christian; Seegert, Nico

    2018-04-01

    The tremendous progress in high-intensity laser technology and the establishment of dedicated high-field laboratories in recent years have paved the way towards a first observation of quantum vacuum nonlinearities at the high-intensity frontier. We advocate a particularly prospective scenario, where three synchronized high-intensity laser pulses are brought into collision, giving rise to signal photons, whose frequency and propagation direction differ from the driving laser pulses, thus providing various means to achieve an excellent signal to background separation. Based on the theoretical concept of vacuum emission, we employ an efficient numerical algorithm which allows us to model the collision of focused high-intensity laser pulses in unprecedented detail. We provide accurate predictions for the numbers of signal photons accessible in experiment. Our study is the first to predict the precise angular spread of the signal photons, and paves the way for a first verification of quantum vacuum nonlinearity in a well-controlled laboratory experiment at one of the many high-intensity laser facilities currently coming online.

  4. Improved Light Extraction Efficiency by Photonic Crystal Arrays on Transparent Contact Layer Using Focused Ion Beams

    International Nuclear Information System (INIS)

    Wu, G.M.; Tsai, B.H.; Kung, S.F.; Wu, C.F.

    2011-01-01

    Nitride-based thin-film materials have become increasingly important for the high brightness light-emitting diode applications. The improvements in light extraction and lower power consumption are highly desired. Although the internal quantum efficiency of GaN-based LED has been relatively high, only a small fraction of light can be extracted. In this study, a new design of two-dimensional photonic crystal array has been prepared on the top transparent contact layer of indium-tin oxide film to improve the light extraction efficiency using focused ion beam. The acceleration voltage of the Ga dual-beam nanotechnology system SMI 3050 was 30 kV and the ion beam current was 100 pA. The cylindrical air holes had the diameter of 150 nm and depth of 100 nm. The micro photoluminescence analysis results showed that the light output intensity could be 1.5 times of that of the non-patterned control sample. In addition, the structural damage from the focused ion beam drilling of GaN step could be eliminated. The excellent I-V characteristics have been maintained, and the external light extraction efficiency would be still improved for the LED devices. (author)

  5. [Extramedullary fixation combined with intramedullary fixation in the surgical reduction of sagittal mandibular condylar fractures].

    Science.gov (United States)

    Chuanjun, Chen; Xiaoyang, Chen; Jing, Chen

    2016-10-01

    This study aimed to evaluate the clinical effect of extramedullary fixation combined with intramedullary fixation during the surgical reduction of sagittal mandibular condylar fractures. Twenty-four sagittal fractures of the mandibular condyle in18 patients were fixed by two appliances: intramedullary with one long-screw osteosynthesis or Kirschner wire and extramedullary with one micro-plate. The radiologically-recorded post-operative stability-associated com-plications included the screw/micro-plate loosening, micro-plate twisting, micro-plate fractures, and fragment rotation. The occluding relations, the maximalinter-incisal distances upon mouth opening, and the mandibular deflection upon mouth opening were evaluated based on follow-up clinical examination. Postoperative panoramic X-ray and CT scans showed good repositioning of the fragment, with no redislocation or rotation, no screw/plate loosening, and no plate-twisting or fracture. Clinical examination showed that all patients regained normal mandibular movements, ideal occlusion, and normal maximal inter-incisal distances upon mouth opening. Extramedullary fixation combined with intramedullary fixation is highly recommended for sagittal condylar fractures because of the anti-rotation effect of the fragment and the reasonable place-ment of the fixation appliances.

  6. Comparing the Effectiveness of Sagittal Balance, Foraminal Stenosis, and Preoperative Cord Rotation in Predicting Postoperative C5 Palsy.

    Science.gov (United States)

    Chugh, Arunit J S; Weinberg, Douglas S; Alonso, Fernando; Eubanks, Jason D

    2017-11-01

    Retrospective cohort review. To determine whether preoperative cord rotation is independently correlated with C5 palsy when analyzed alongside measures of sagittal balance and foraminal stenosis. Postoperative C5 palsy is a well-documented complication of cervical procedures with a prevalence of 4%-8%. Recent studies have shown a correlation with preoperative spinal cord rotation. There have been few studies, however, that have examined the role of sagittal balance and foraminal stenosis in the development of C5 palsy. A total of 77 patients who underwent cervical decompression-10 of whom developed C5 palsy-were reviewed. Sagittal balance was assessed using curvature angle and curvature index on radiographs and magnetic resonance image (MRI). Cord rotation was assessed on axial MRI. C4-C5 foraminal stenosis was assessed on sagittal MRI using area measurements and a grading scale. Demographics and information on surgical approach were gathered from chart review. Correlation with C5 palsy was performed by point-biserial, χ, and regression analyses. Point-biserial analysis indicated that only cord rotation showed significance (Pbalance did not correlate with presence of C5 palsy. Logistic regression model yielded cord rotation as the only significant independent predictor of C5 palsy. For every degree of axial cord rotation, the likelihood ratio for suffering a C5 palsy was 3.93 (95% confidence interval, 2.01-8.66; Ppoints to mechanisms other than direct compression as the etiology. In addition, the lack of correlation with postoperative changes in sagittal balance hints that measures of curvature angle and curvature index may not be appropriate to accurately predict this complication. Level 3.

  7. Sagittal reconstruction computed tomography in metrizamide cisternography. Useful diagnostic procedure for malformations in craniovertebral junction and posterior fossa

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, H.; Okita, N.; Fujii, T.; Yoshioka, M.; Saito, H. (Tohoku Univ., Sendai (Japan). School of Medicine)

    1982-08-01

    We studied the sagittal reconstruction technique in computed tomography with metrizamide. Ten ml of metrizamide, 170 mg iodine/ml in concentration, were injected by lumbar puncture. After diffusion of the injected metrizamide, axial computed tomograms were taken by thin slice width (5 mm) with overlapped technique. Then electrical sagittal reconstruction was carried out by optioned software. Injection of metrizamide, non-ionic water soluble contrast media, made clear contrasts among bone, brain parenchyma and cerebrospinal fluid with computed tomography. Sagittal reconstruction technique could reveal more precise details and accurate anatomical relations than ordinary axial computed tomography. This technique was applied on 3 cases (Arnold-Chiari malformation, large cisterna magna and partial agenesis cerebellar vermis), which demonstrated a useful diagnostic procedure for abnormalities of craniovertebral junction and posterior fossa. The adverse reactions of metrizamide were negligible in our series.

  8. Amorphous photonic crystals with only short-range order.

    Science.gov (United States)

    Shi, Lei; Zhang, Yafeng; Dong, Biqin; Zhan, Tianrong; Liu, Xiaohan; Zi, Jian

    2013-10-04

    Distinct from conventional photonic crystals with both short- and long-range order, amorphous photonic crystals that possess only short-range order show interesting optical responses owing to their unique structural features. Amorphous photonic crystals exhibit unique light scattering and transport, which lead to a variety of interesting phenomena such as isotropic photonic bandgaps or pseudogaps, noniridescent structural colors, and light localization. Recent experimental and theoretical advances in the study of amorphous photonic crystals are summarized, focusing on their unique optical properties, artificial fabrication, bionspiration, and potential applications. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Negative refraction at infrared wavelengths in a two-dimensional photonic crystal

    International Nuclear Information System (INIS)

    Berrier, A.; Mulot, M.; Swillo, M.; Qiu, M.; Thylen, L.; Anand, S.; Talneau, A.

    2004-01-01

    We report on the first experimental evidence of negative refraction at telecommunication wavelengths by a two-dimensional photonic crystal field. Samples were fabricated by chemically assisted ion beam etching in the InP-based low-index constrast system. Experiments of beam imaging and light collection show light focusing by the photonic crystal field. Finite-difference time-domain simulations confirm that the observed focusing is due to negative refraction in the photonic crystal area

  10. Dressed photons from the viewpoint of photon localization: the entrance to the off-shell science

    Science.gov (United States)

    Saigo, Hayato; Ojima, Izumi; Ohtsu, Motoichi

    2017-12-01

    In the present paper, a new aspect of the interplay is examined between mathematical-physical arguments and light-matter fusion technologies in terms of the concept of "effective mass", starting from a question: Who has seen a free photon? Owing to the general results due to Newton-Wigner and to Wightman, a position operator is absent for massless free particles with non-zero finite spins, and hence, we cannot observe free photons in any local space regions. To solve this paradox of "photon localization", the effective mass of a photon needs to be generated through the couplings of photons with matter. Here "polaritons" picture as a basic notion in optical and solid physics is shown to verify this viewpoint, which is seen to apply also to more general settings . Focusing on the role played by nanoparticles, we reach a new look at the notion of "dressed photons" as off-shell particles. The perspective above shows that essential mathematical structure of quantum field theory for the so-called elementary particles in subatomic scale can also be applied to certain phenomena in the nano-scale.

  11. Nonclassical light sources for silicon photonics

    Science.gov (United States)

    Bajoni, Daniele; Galli, Matteo

    2017-09-01

    Quantum photonics has recently attracted a lot of attention for its disruptive potential in emerging technologies like quantum cryptography, quantum communication and quantum computing. Driven by the impressive development in nanofabrication technologies and nanoscale engineering, silicon photonics has rapidly become the platform of choice for on-chip integration of high performing photonic devices, now extending their functionalities towards quantum-based applications. Focusing on quantum Information Technology (qIT) as a key application area, we review recent progress in integrated silicon-based sources of nonclassical states of light. We assess the state of the art in this growing field and highlight the challenges that need to be overcome to make quantum photonics a reliable and widespread technology.

  12. Photon technology. Hard photon technology; Photon technology. Hard photon gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    For the application of photon to industrial technologies, in particular, a hard photon technology was surveyed which uses photon beams of 0.1-200nm in wavelength. Its features such as selective atom reaction, dense inner shell excitation and spacial high resolution by quantum energy are expected to provide innovative techniques for various field such as fine machining, material synthesis and advanced inspection technology. This wavelength region has been hardly utilized for industrial fields because of poor development of suitable photon sources and optical devices. The developmental meaning, usable time and issue of a hard photon reduction lithography were surveyed as lithography in ultra-fine region below 0.1{mu}m. On hard photon analysis/evaluation technology, the industrial use of analysis, measurement and evaluation technologies by micro-beam was viewed, and optimum photon sources and optical systems were surveyed. Prediction of surface and surface layer modification by inner shell excitation, the future trend of this process and development of a vacuum ultraviolet light source were also surveyed. 383 refs., 153 figs., 17 tabs.

  13. Two-photon decay in heavy atoms and ions

    International Nuclear Information System (INIS)

    Mokler, P.H.; Dunford, R.W

    2003-08-01

    We review the status of and comment on current developments in the field of two-photon decay in atomic physics research. Recent work has focused on two-photon decays in highly-charged ions and two-photon decay of inner-shell vacancies in heavy neutral atoms. We emphasize the importance of measuring the shape of the continuum emission in two-photon decay as a probe of relativistic effects in the strong central fields found in heavy atomic systems. New experimental approaches and their consequences will be discussed. (orig.)

  14. Surgical treatment of sagittal fracture of mandibular condyle using long-screw osteosynthesis.

    Science.gov (United States)

    Luo, Shufang; Li, Bo; Long, Xing; Deng, Mohong; Cai, Hengxing; Cheng, Yong

    2011-07-01

    The retrospective study evaluated long-screw (bicortical screw) osteosynthesis used in the surgical treatment of sagittal fracture of the mandibular condyle and compared it with titanium plates and removal of the condylar fragment. Ninety-five patients with sagittal fracture of the mandibular condyle received open surgical treatment from 1997 to 2008. Among these patients, the condylar fragments were fixed with long screws in 56 cases (group A), were fixed with titanium plates in 12 cases (group B), and were completely removed in 24 cases (group C). Follow-up was carried out clinically and radiologically. The clinical features included limitation of mandibular mobility, occlusion disturbance, lateral deviation on mouth opening, joint pain, clicking, facial asymmetry, and patient's subjective evaluation. The radiologic parameters consisted of degree of bony resorption, bony change, change of osteosynthesis material, and shortening of mandibular ramus height. Anatomic reduction and functional restoration were obtained and no severe complication was detected in group A. However, 3 of 14 patients had severe osteoarthrosis and 2 of 14 patients had ankylosis in group B. In group C 3 of 24 patients had mandibular retrusion, 4 of 24 patients had front teeth open bite, 4 of 24 patients had severe osteoarthrosis, and 1 of 24 patients had ankylosis. The long-screw fixation group had a more favorable prognosis than the titanium plate group and the group in which removal of the condylar fragment was performed. The long-screw fixation technique might be suitable for use in the surgical treatment of sagittal fractures of the mandibular condyle. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Photonic crystals: features and applications (physics research and technology)

    CERN Document Server

    2013-01-01

    The present book is focused on the study of unprecedented control and manipulation of light by photonic crystals (PCs) and their applications. These are micro- or usually nano-structures composed of periodic indexes of refraction of dielectrics with high refractive index contrast. They exhibit optical frequency band gaps in analogy to electronic bands for a periodic potential of a semiconductor crystal lattice. The gemstone opal and butterflys feathers colours are already referred to as natural examples of photonic crystals. The characteristics of such supper-lattices were first reported by Yablonovitch in 1987. The exploitation of photonic crystals is a promising tool in communication, sensors, optical computing, and nanophotonics. Discussed are the various features of one-dimensional (1D) and two-dimensional (2D) photonic crystals, photonic quasi crystals, heterostuctures and PC fibres under a variety of conditions using several materials, and metamaterials. It also focuses on the applications of PCs in opt...

  16. Development of synthetic simulators for endoscope-assisted repair of metopic and sagittal craniosynostosis.

    Science.gov (United States)

    Eastwood, Kyle W; Bodani, Vivek P; Haji, Faizal A; Looi, Thomas; Naguib, Hani E; Drake, James M

    2018-06-01

    OBJECTIVE Endoscope-assisted repair of craniosynostosis is a safe and efficacious alternative to open techniques. However, this procedure is challenging to learn, and there is significant variation in both its execution and outcomes. Surgical simulators may allow trainees to learn and practice this procedure prior to operating on an actual patient. The purpose of this study was to develop a realistic, relatively inexpensive simulator for endoscope-assisted repair of metopic and sagittal craniosynostosis and to evaluate the models' fidelity and teaching content. METHODS Two separate, 3D-printed, plastic powder-based replica skulls exhibiting metopic (age 1 month) and sagittal (age 2 months) craniosynostosis were developed. These models were made into consumable skull "cartridges" that insert into a reusable base resembling an infant's head. Each cartridge consists of a multilayer scalp (skin, subcutaneous fat, galea, and periosteum); cranial bones with accurate landmarks; and the dura mater. Data related to model construction, use, and cost were collected. Eleven novice surgeons (residents), 9 experienced surgeons (fellows), and 5 expert surgeons (attendings) performed a simulated metopic and sagittal craniosynostosis repair using a neuroendoscope, high-speed drill, rongeurs, lighted retractors, and suction/irrigation. All participants completed a 13-item questionnaire (using 5-point Likert scales) to rate the realism and utility of the models for teaching endoscope-assisted strip suturectomy. RESULTS The simulators are compact, robust, and relatively inexpensive. They can be rapidly reset for repeated use and contain a minimal amount of consumable material while providing a realistic simulation experience. More than 80% of participants agreed or strongly agreed that the models' anatomical features, including surface anatomy, subgaleal and subperiosteal tissue planes, anterior fontanelle, and epidural spaces, were realistic and contained appropriate detail. More

  17. Inclusive hard processes in photon-photon and photon-proton interactions

    OpenAIRE

    Glasman, Claudia

    1999-01-01

    Measurements of jet, prompt photon, high-pT hadron and heavy quark production in photon-induced processes provide tests of QCD and are sensitive to the photon parton densities. A review of the latest experimental results in photon-photon and photon-proton interactions is presented. Next-to-leading-order QCD calculations for these measurements are discussed.

  18. Massive hidden photons as lukewarm dark matter

    International Nuclear Information System (INIS)

    Redondo, Javier; Postma, Marieke

    2008-11-01

    We study the possibility that a keV-MeV mass hidden photon (HP), i.e. a hidden sector U(1) gauge boson, accounts for the observed amount of dark matter. We focus on the case where the HP interacts with the standard model sector only through kinetic mixing with the photon. The relic abundance is computed including all relevant plasma effects into the photon's self-energy, which leads to a resonant yield almost independent of the HP mass. The HP can decay into three photons. Moreover, if light enough it can be copiously produced in stars. Including bounds from cosmic photon backgrounds and stellar evolution, we find that the hidden photon can only give a subdominant contribution to the dark matter. This negative conclusion may be avoided if another production mechanism besides kinetic mixing is operative. (orig.)

  19. Massive hidden photons as lukewarm dark matter

    Energy Technology Data Exchange (ETDEWEB)

    Redondo, Javier [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Postma, Marieke [Nationaal Inst. voor Kernfysica en Hoge-Energiefysica (NIKHEF), Amsterdam (Netherlands)

    2008-11-15

    We study the possibility that a keV-MeV mass hidden photon (HP), i.e. a hidden sector U(1) gauge boson, accounts for the observed amount of dark matter. We focus on the case where the HP interacts with the standard model sector only through kinetic mixing with the photon. The relic abundance is computed including all relevant plasma effects into the photon's self-energy, which leads to a resonant yield almost independent of the HP mass. The HP can decay into three photons. Moreover, if light enough it can be copiously produced in stars. Including bounds from cosmic photon backgrounds and stellar evolution, we find that the hidden photon can only give a subdominant contribution to the dark matter. This negative conclusion may be avoided if another production mechanism besides kinetic mixing is operative. (orig.)

  20. Anomalous transparency in photonic crystals and its application to point-by-point grating inscription in photonic crystal fibers.

    Science.gov (United States)

    Baghdasaryan, Tigran; Geernaert, Thomas; Chah, Karima; Caucheteur, Christophe; Schuster, Kay; Kobelke, Jens; Thienpont, Hugo; Berghmans, Francis

    2018-04-03

    It is common belief that photonic crystals behave similarly to isotropic and transparent media only when their feature sizes are much smaller than the wavelength of light. Here, we counter that belief and we report on photonic crystals that are transparent for anomalously high normalized frequencies up to 0.9, where the crystal's feature sizes are comparable with the free space wavelength. Using traditional photonic band theory, we demonstrate that the isofrequency curves can be circular in the region above the first stop band for triangular lattice photonic crystals. In addition, by simulating how efficiently a tightly focused Gaussian beam propagates through the photonic crystal slab, we judge on the photonic crystal's transparency rather than on isotropy only. Using this approach, we identified a wide range of photonic crystal parameters that provide anomalous transparency. Our findings indicate the possibility to scale up the features of photonic crystals and to extend their operational wavelength range for applications including optical cloaking and graded index guiding. We applied our result in the domain of femtosecond laser micromachining, by demonstrating what we believe to be the first point-by-point grating inscribed in a multi-ring photonic crystal fiber.

  1. The Role of Proprioception in the Sagittal Setting of Anticipatory Postural Adjustments During Gait Initiation

    Directory of Open Access Journals (Sweden)

    Pereira Marcelo P.

    2015-12-01

    Full Text Available Purpose. Previous studies have studied the role of proprioception on the setting of anticipatory postural adjustments (APA during gait initiation. However, these studies did not investigate the role of proprioception in the sagittal APA setting. We aimed to investigate the role of proprioception manipulation to induce APA sagittal adaptations on gait initiation. Methods. Fourteen healthy adults performed gait initiation without, and with, vibration applied before movement onset, and during movement. In addition, the effects of two different vibration frequencies (80 and 120Hz were tested. Vibration was applied bilaterally on the tibialis anterior, rectus femoris and trapezius superior. The first step characteristics, ground reaction forces and CoP behaviour were assessed. Results. Vibration improved gait initiation performance regardless of the moment it was applied. CoP velocity during the initial phase of APA was increased by vibration only when it was applied before movement. When vibration was applied to disturb the movement, no effects on the CoP behaviour were observed. Manipulation of vibration frequency had no effects. Conclusions. Rather than proprioception manipulation, the results suggest that post-vibratory effects and attentional mechanisms were responsible for our results. Taken together, the results show that sagittal APA setting is robust to proprioception manipulation.

  2. The irreducible photon

    Science.gov (United States)

    Andrews, David L.

    2009-08-01

    In recent years it has become evident that the primary concept of the photon has multiple interpretations, with widely differing secondary connotations. Despite the all-pervasive nature of this concept in science, some of the ancillary properties with which the photon is attributed in certain areas of application sit uneasily alongside those invoked in other areas. Certainly the range of applications extends far beyond what was envisaged in the original conception, now entering subjects extending from elementary particle physics and cosmology through to spectroscopy, statistical mechanics and photochemistry. Addressing this diverse context invites the question: What is there, that it is possible to assert as incontrovertibly true about the photon? Which properties are non-controversial, if others are the subject of debate? This paper describes an attempt to answer these questions, establishing as far as possible an irreducible core of what can rightly be asserted about the photon, and setting aside some of what often is, but should never be so asserted. Some of the more bewildering difficulties and differences of interpretation owe their origin to careless descriptions, highlighting a need to guard semantic precision; although simplifications are frequently and naturally expedient for didactic purposes, they carry the risk of becoming indelible. Focusing on such issues, the aim is to identify how much or how little about the photon can be regarded as truly non-controversial.

  3. Photon-photon interactions

    International Nuclear Information System (INIS)

    Gilman, F.J.

    1980-01-01

    A brief summary of the present status of photon-photon interactions is presented. Stress is placed on the use of two-photon collisions to test present ideas on the quark constituents of hadrons and on the theory of strong interactions

  4. Does Andrews facial analysis predict esthetic sagittal maxillary position?

    Science.gov (United States)

    Resnick, Cory M; Daniels, Kimberly M; Vlahos, Maryann

    2018-04-01

    Cephalometric analyses have limited utility in planning maxillary sagittal position for orthognathic surgery. In Six Elements of Orofacial Harmony, Andrews quantified maxillary position relative to forehead projection and angulation and proposed an ideal relationship. The purpose of this study was to investigate the ability of this technique to predict esthetic sagittal maxillary position. Survey study including a male and female with straight facial profiles, normal maxillary incisor angulations, and Angle's Class I. Maxillary position was modified on lateral photographs to create 5 images for each participant with incisor-goal anterior limit line (GALL) distances of -4, -2, 0, +2, and +4 mm. A series of health care professionals and laypeople were asked to rate each photo in order of attractiveness. A total of 100 complete responses were received. Incisor-GALL distances of +4 mm (41%) and +2 mm (40%) were most commonly considered "most esthetic" for the female volunteer (P < .001). For the male volunteer, there were 2 peak "most esthetic" responses: incisor-GALL distances of 0 mm (37%) and -4 mm (32%) (P < .001). Respondents considered maxillary incisor position 2 to 4 mm anterior to GALL most attractive in a woman and 0 to 4 mm posterior to GALL most esthetic in a man. Using these modified target distances, this analysis may be useful for orthognathic surgery planning. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Transforaminal Anterior Release for the Treatment of Fixed Sagittal Imbalance and Segmental Kyphosis, Minimum 2-Year Follow-Up Study.

    Science.gov (United States)

    Sweet, Fred A; Sweet, Andrea

    2015-09-01

    Retrospective review of prospectively accrued patient cohort. To report minimum 2 years' follow-up after a single-surgeon series of 47 consecutive patients in whom fixed sagittal imbalance or segmental kyphosis was treated with a novel unilateral transforaminal annular release. Fixed sagittal imbalance has been treated most recently with pedicle subtraction osteotomy with great success but is associated with significant blood loss and neurologic risk. Forty-seven consecutive patients with fixed sagittal imbalance (n = 29) or segmental kyphosis (n = 18) were treated by a single surgeon with a single-level transforaminal anterior release (TFAR) to effect an opening wedge correction. Sagittal and coronal correction was performed with in situ rod contouring. An interbody cage was captured in the disc space with rod compression. Radiographic and clinical outcome analysis was performed with a minimum 2-year follow-up (range 2-7.8 years). The average increase in lordosis was 36° (range 24°-56°) in the fixed sagittal deformity group. Coronal corrections averaged 34° (range 18°-48°). The average improvement in plumb line was 13.6 cm. There were four pseudarthroses, one at the TFAR. Average blood loss was 578 mL (range 200-1,200). One patient had a transient grade 4/5 anterior tibialis weakness. There were no vascular injuries or permanent neurologic deficits. There were significant improvements in the Oswestry Disability Index (p imbalance with relatively low blood loss and was found to be neurologically safe in this single-surgeon series. Therapeutic study, Level IV (case series, no control group). Copyright © 2015 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  6. Sagittal balance in scoliosis associated with Marfan syndrome: a stereoradiographic three-dimensional analysis.

    Science.gov (United States)

    Glard, Yann; Pomero, Vincent; Collignon, Patrick; Skalli, Wafa; Jouve, Jean-Luc; Bollini, Gérard

    2008-03-01

    Marfan syndrome (MFS) is a genetic disease often marked by the presence of scoliosis. There is no three-dimensional analysis of the deformity in the literature. Our aim was to determine what kind of sagittal balance defines scoliosis associated with MFS, namely a flexion deformity, as it is in scoliosis associated with Chiari I or an extension deformity, as in adolescent idiopathic scoliosis (AIS). To address this issue, we compared the presence or absence of a thoracic scoliosis with the presence or absence of a segment in extension in the thoracic spine. In our series, 30 patients diagnosed with Marfan syndrome were prospectively included. In each patient, personalized three-dimensional reconstruction from T1 to L5 of the spine was made using stereoradiography. The patients were first separated based on the presence or absence of thoracic scoliosis, in order to compare this with the presence or absence of a segment in extension in the thoracic spine. They were then classified into two groups based on the presence or absence of the segment in extension (meaning containing negative values of inter-vertebral sagittal rotation) in the thoracic spine. Among scoliotic patients with a thoracic scoliosis (17 cases), there were 13 (76.5% cases) with a segment in extension in the thoracic spine and 4 with no segment in extension. Our results showed that scoliosis associated with MFS is somehow original, demonstrating a sagittal balance in extension (as AIS) in about 80% of thoracic curves, but without this characteristic feature in about 20%.

  7. Prenatal MR imaging of Dandy-Walker complex: Midline sagittal area analysis

    International Nuclear Information System (INIS)

    Wong, Alex M.; Bilaniuk, Larissa T.; Zimmerman, Robert A.; Liu, P.L.

    2012-01-01

    Objective: To measure the mid-sagittal areas of vermis (VA) and of posterior fossa (PFA) and determine their differences among fetuses with various Dandy-Walker (DW) entities and control subjects. Methods: We reviewed data in 25 fetal patients with a MR diagnosis of DW complex including hypoplastic vermis (HV), HV with rotation (HVR), and mega cistern magna (MCM), and in 85 fetal controls with normal CNS. PFA and VA of each subject were manually traced on mid-sagittal MR images. Regarding each of VA and PFA, after age correction, we determined statistically significant differences among HVR, HV, MCM, and control groups. Results: The mean VA residue of MCM was greater than that of the control, which was in turn greater than those of HVR and HV. The mean PF residue of the control was smaller than all other groups. Conclusion: Fetuses with HVR or HV had smaller VA than fetuses with MCM or control subjects. Fetuses with MCM, HVR, or HV had larger PFA than control subjects. These results may be an early step leading to better understanding of the confusion about the PF anomalies in future.

  8. Comparing Outcomes and Cost of 3 Surgical Treatments for Sagittal Synostosis: A Retrospective Study Including Procedure-Related Cost Analysis.

    Science.gov (United States)

    Garber, Sarah T; Karsy, Michael; Kestle, John R W; Siddiqi, Faizi; Spanos, Stephen P; Riva-Cambrin, Jay

    2017-10-01

    Neurosurgical techniques for repair of sagittal synostosis include total cranial vault (TCV) reconstruction, open sagittal strip (OSS) craniectomy, and endoscopic strip (ES) craniectomy. To evaluate outcomes and cost associated with these 3 techniques. Via retrospective chart review with waiver of informed consent, the last consecutive 100 patients with sagittal synostosis who underwent each of the 3 surgical correction techniques before June 30, 2013, were identified. Clinical, operative, and process of care variables and their associated specific charges were analyzed along with overall charge. The study included 300 total patients. ES patients had fewer transfusion requirements (13% vs 83%, P cost savings compared with the TCV reconstruction. The charges were similar to those incurred with OSS craniectomy, but patients had a shorter length of stay and fewer revisions. Copyright © 2017 by the Congress of Neurological Surgeons

  9. A fully-automated multiscale kernel graph cuts based particle localization scheme for temporal focusing two-photon microscopy

    Science.gov (United States)

    Huang, Xia; Li, Chunqiang; Xiao, Chuan; Sun, Wenqing; Qian, Wei

    2017-03-01

    The temporal focusing two-photon microscope (TFM) is developed to perform depth resolved wide field fluorescence imaging by capturing frames sequentially. However, due to strong nonignorable noises and diffraction rings surrounding particles, further researches are extremely formidable without a precise particle localization technique. In this paper, we developed a fully-automated scheme to locate particles positions with high noise tolerance. Our scheme includes the following procedures: noise reduction using a hybrid Kalman filter method, particle segmentation based on a multiscale kernel graph cuts global and local segmentation algorithm, and a kinematic estimation based particle tracking method. Both isolated and partial-overlapped particles can be accurately identified with removal of unrelated pixels. Based on our quantitative analysis, 96.22% isolated particles and 84.19% partial-overlapped particles were successfully detected.

  10. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    International Nuclear Information System (INIS)

    Lee, Myoung Seok; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup; Park, Joong Shin; Jun, Jong Kwan

    2017-01-01

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP

  11. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok [Dept. of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Joong Shin; Jun, Jong Kwan [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2017-01-15

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP.

  12. One-way quantum computation with four-dimensional photonic qudits

    International Nuclear Information System (INIS)

    Joo, Jaewoo; Knight, Peter L.; O'Brien, Jeremy L.; Rudolph, Terry

    2007-01-01

    We consider the possibility of performing linear optical quantum computations making use of extra photonic degrees of freedom. In particular, we focus on the case where we use photons as quadbits, four-dimensional photonic qudits. The basic 2-quadbit cluster state is a hyperentangled state across polarization and two spatial mode degrees of freedom. We examine the nondeterministic methods whereby such states can be created from single photons and/or Bell pairs and then give some mechanisms for performing higher-dimensional fusion gates

  13. Subjective alveolar nerve function after bilateral sagittal split osteotomy or distraction osteogenesis of mandible

    NARCIS (Netherlands)

    Baas, E.M.; Horsthuis, R.B.G.; de Lange, J.

    2012-01-01

    Purpose: The present retrospective cohort study compared the subjective inferior alveolar nerve (IAN) function after distraction osteogenesis (DOG) and bilateral sagittal split osteotomy (BSSO) in mandibular advancement surgery. Materials and Methods: Treatment consisted of correction of a

  14. Subjective Alveolar Nerve Function After Bilateral Sagittal Split Osteotomy or Distraction Osteogenesis of Mandible

    NARCIS (Netherlands)

    Baas, Erik M.; Horsthuis, Roy B. G.; de Lange, Jan

    2012-01-01

    Purpose: The present retrospective cohort study compared the subjective inferior alveolar nerve (IAN) function after distraction osteogenesis (DOG) and bilateral sagittal split osteotomy (BSSO) in mandibular advancement surgery. Materials and Methods: Treatment consisted of correction of a

  15. Molecular photosensitisers for two-photon photodynamic therapy.

    Science.gov (United States)

    Bolze, F; Jenni, S; Sour, A; Heitz, V

    2017-11-30

    Two-photon excitation has attracted the attention of biologists, especially after the development of two-photon excited microscopy in the nineties. Since then, new applications have rapidly emerged such as the release of biologically active molecules and photodynamic therapy (PDT) using two-photon excitation. PDT, which requires a light-activated drug (photosensitiser), is a clinically approved and minimally invasive treatment for cancer and for non-malignant diseases. This feature article focuses on the engineering of molecular two-photon photosensitisers for PDT, which should bring important benefits to the treatment, increase the treatment penetration depth with near-infrared light excitation, improve the spatial selectivity and reduce the photodamage to healthy tissues. After an overview of the two-photon absorption phenomenon and the methods to evaluate two-photon induced phototoxicity on cell cultures, the different classes of photosensitisers described in the literature are discussed. The two-photon PDT performed with historical one-photon sensitisers are briefly presented, followed by specifically engineered cyclic tetrapyrrole photosensitisers, purely organic photosensitisers and transition metal complexes. Finally, targeted two-photon photosensitisers and theranostic agents that should enhance the selectivity and efficiency of the treatment are discussed.

  16. Impact of Cervical Sagittal Alignment on Axial Neck Pain and Health-related Quality of Life After Cervical Laminoplasty in Patients With Cervical Spondylotic Myelopathy or Ossification of the Posterior Longitudinal Ligament: A Prospective Comparative Study.

    Science.gov (United States)

    Fujiwara, Hiroyasu; Oda, Takenori; Makino, Takahiro; Moriguchi, Yu; Yonenobu, Kazuo; Kaito, Takashi

    2018-05-01

    This is prospective observational study. To prospectively investigate the correlation among axial neck pain; a newly developed patient-based quality of life outcome measure, the Japanese Orthopaedic Association Cervical Myelopathy Evaluation Questionnaire (JOACMEQ); and cervical sagittal alignment after open-door laminoplasty for cervical myelopathy. Many studies have focused on postoperative axial neck pain after laminoplasty. However, the correlation among cervical sagittal alignment, neck pain, and JOACMEQ has not been investigated. In total, 57 consecutive patients treated by open-door laminoplasty for cervical myelopathy were included (mean age, 63.7 y; 15 women and 42 men) and divided into 2 groups according to diagnosis [cervical spondylotic myelopathy (CSM) group: 35 patients, and ossification of the posterior longitudinal ligament (OPLL) group: 22 patients]. JOA score, a subdomain of cervical spine function (CSF) in the JOACMEQ, and the visual analog scale for axial neck pain were assessed preoperatively and 12 months postoperatively. Radiographic cervical sagittal parameters were measured by C2 sagittal vertical axis (C2 SVA), C2-C7 lordosis, C7 sagittal slope (C7 slope), and range of motion. C2 SVA values in both groups shifted slightly anteriorly between preoperative and 12-month postoperative measurements (CSM: +19.7±10.9 mm; OPLL: +22.1±13.4 mm vs. CSM: +23.2±16.1 mm; OPLL: +28.7±15.4 mm, respectively). Postoperative axial neck pain in the OPLL group showed strong negative correlations with C2 SVA and C7 slope. Strong negative correlations were found between axial neck pain and CSF in both the preoperative CSM and OPLL groups (CSM: r=-0.45, P=0.01; OPLL: r=-0.61, Ppain and CSF in the postoperative OPLL group (r=-0.51, P=0.05). This study demonstrated a significant negative correlation between neck pain and CSF in both the CSM and OPLL groups preoperatively and in the OPLL group postoperatively. Radiographic cervical sagittal alignment

  17. CONFERENCE: Photon-photon collisions

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    Despite being difficult to observe, photon-photon collisions have opened up a range of physics difficult, or even impossible, to access by other methods. The progress which has been made in this field was evident at the fifth international workshop on photon-photon collisions, held in Aachen from 13-16 April and attended by some 120 physicists

  18. Integrated Ultrasonic-Photonic Devices

    DEFF Research Database (Denmark)

    Barretto, Elaine Cristina Saraiva

    in channel waveguides and Mach-Zehnder interferometers. Numerical models are developed based on the finite element method, and applied to several scenarios, such as optimization of the geometrical parameters of waveguides, use of slow light in photonic crystal waveguides and use of Lamb waves in membranized......This thesis deals with the modeling, design, fabrication and characterization of integrated ultrasonic-photonic devices, with particular focus on the use of standard semiconductor materials such as GaAs and silicon. The devices are based on the use of guided acoustic waves to modulate the light...... investigated. Comparisons are made with the numerical and experimental results, and they validate the obtained response of the acoustic and photonic components of the device. Finally, a new design for an optical frequency shifter is proposed, posing several advantages over existing devices in terms of size...

  19. High-pressure pair distribution function (PDF) measurement using high-energy focused x-ray beam

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Xinguo, E-mail: xhong@bnl.gov; Weidner, Donald J. [Mineral Physics Institute, Stony Brook University, Stony Brook, NY 11794 (United States); Ehm, Lars [Mineral Physics Institute, Stony Brook University, Stony Brook, NY 11794 (United States); National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973 (United States); Zhong, Zhong; Ghose, Sanjit [National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973 (United States); Duffy, Thomas S. [Department of Geosciences, Princeton University, Princeton, NJ 08544 (United States)

    2016-07-27

    In this paper, we report recent development of the high-pressure pair distribution function (HP-PDF) measurement technique using a focused high-energy X-ray beam coupled with a diamond anvil cell (DAC). The focusing optics consist of a sagittally bent Laue monochromator and Kirkpatrick-Baez (K–B) mirrors. This combination provides a clean high-energy X-ray beam suitable for HP-PDF research. Demonstration of the HP-PDF technique for nanocrystalline platinum under quasi-hydrostatic condition above 30 GPa is presented.

  20. Extended two-photon microscopy in live samples with Bessel beams: steadier focus, faster volume scans, and simpler stereoscopic imaging.

    Science.gov (United States)

    Thériault, Gabrielle; Cottet, Martin; Castonguay, Annie; McCarthy, Nathalie; De Koninck, Yves

    2014-01-01

    Two-photon microscopy has revolutionized functional cellular imaging in tissue, but although the highly confined depth of field (DOF) of standard set-ups yields great optical sectioning, it also limits imaging speed in volume samples and ease of use. For this reason, we recently presented a simple and retrofittable modification to the two-photon laser-scanning microscope which extends the DOF through the use of an axicon (conical lens). Here we demonstrate three significant benefits of this technique using biological samples commonly employed in the field of neuroscience. First, we use a sample of neurons grown in culture and move it along the z-axis, showing that a more stable focus is achieved without compromise on transverse resolution. Second, we monitor 3D population dynamics in an acute slice of live mouse cortex, demonstrating that faster volumetric scans can be conducted. Third, we acquire a stereoscopic image of neurons and their dendrites in a fixed sample of mouse cortex, using only two scans instead of the complete stack and calculations required by standard systems. Taken together, these advantages, combined with the ease of integration into pre-existing systems, make the extended depth-of-field imaging based on Bessel beams a strong asset for the field of microscopy and life sciences in general.

  1. BMD measurements of the spine derived from sagittal reformations of contrast-enhanced MDCT without dedicated software

    Energy Technology Data Exchange (ETDEWEB)

    Baum, Thomas, E-mail: thbaum@gmx.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Mueller, Dirk, E-mail: dirk.mueller@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Dobritz, Martin, E-mail: dobritz@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Rummeny, Ernst J., E-mail: institut@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Link, Thomas M., E-mail: thomas.link@radiology.ucsf.edu [Musculoskeletal and Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, San Francisco, CA 94107 (United States); Bauer, Jan S., E-mail: jsb@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany)

    2011-11-15

    Purpose: To assess QCT equivalent BMD of the lumbar spine in sagittal reformations of routine abdominal contrast-enhanced MDCT with simple PACS measurement tools and to apply this method to MDCT datasets for differentiating patients with and without osteoporotic vertebral fractures. Materials and methods: Eight postmenopausal women (65 {+-} 5years) underwent standard QCT to assess BMD of L1-L3. Afterwards routine abdominal contrast-enhanced MDCT images of these women were obtained and apparent BMD of L1-L3 was measured using the sagittal reformations. The MDCT-to-QCT conversion equation for BMD was calculated with linear regression analysis. The conversion equation was applied to vertebral BMD datasets (L1-L3) of 75 postmenopausal women (66 {+-} 4years). Seventeen of the 75 patients had osteoporotic vertebral fractures. Results: BMD values of contrast-enhanced MDCT were on average 56 mg/ml higher than those of standard QCT. A correlation coefficient of r = 0.94 (p < 0.05) was calculated for the BMD values of MDCT and standard QCT with the conversion equation BMD{sub QCT} = 0.69 x BMD{sub MDCT} - 11 mg/ml. Accordingly converted BMD values of patients with vertebral fractures were significantly lower than those of patients without vertebral fractures (69 mg/ml vs. 85 mg/ml; p < 0.05). Using ROC analysis to differentiate patients with and without vertebral fractures, AUC = 0.72 was obtained for converted BMD values (p < 0.05). Short- and long-term reproducibility errors for BMD measurements in the sagittal reformations amounted 2.09% and 7.70%, respectively. Conclusion: BMD measurements of the spine could be computed in sagittal reformations of routine abdominal contrast-enhanced MDCT with minimal technical and time effort. Using the conversion equation, the acquired BMD data could differentiate patients with and without osteoporotic vertebral fractures.

  2. Coupling of single quantum dots to a photonic crystal waveguide

    DEFF Research Database (Denmark)

    Lund-Hansen, Toke; Stobbe, Søren; Julsgaard, Brian

    Efficient and high quality single-photon sources is a key element in quantum information processing using photons. As a consequence, much current research is focused on realizing all-solid-state nanophotonic single-photon sources. Single photons can be harvested with high efficiency if the emitter...... is coupled efficiently to a single enhanced mode. One popular approach has been to couple single quantum dots to a nanocavity but a limiting factor in this configuration is that in order to apply the photon it should subsequently be coupled out of the cavity, reducing the overall efficiency significantly...

  3. Role of thoracoscopy for the sagittal correction of hypokyphotic adolescent idiopathic scoliosis patients.

    Science.gov (United States)

    Ferrero, E; Pesenti, S; Blondel, B; Jouve, J L; Mazda, K; Ilharreborde, B

    2014-12-01

    Thoracic adolescent idiopathic scoliosis (AIS) curves (Lenke 1-4) are often characterized by hypokyphosis. Sagittal alignment remains challenging to correct, even with recent posterior segmental instrumentation. Some authors recommend anterior endoscopic release (AER) to reduce anterior column height, and facilitate thoracic kyphosis correction. The aim of this study was to assess the contribution of AER to sagittal correction in hypokyphotic AIS. Fifty-six hypokyphotic (T4T12<20°) AIS patients were included. In group 1 (28 patients), patients first underwent AER, followed by posterior instrumentation and correction 5-7 days later. In group 2 (28 patients), patients underwent the same posterior procedure without AER. Posterior correction was performed in all cases using posteromedial translation and hybrid constructs consisting of lumbar pedicle screws and thoracic sublaminar bands. From radiological measurements performed using low-dose EOS radiographs, the correction of thoracic kyphosis was compared between the two groups. Groups 1 and 2 were comparable regarding demographic data and preoperative thoracic kyphosis (group 1: 11.7° ± 6.9° vs group 2: 12.1° ± 6.3°, p = 0.89). Postoperative thoracic kyphosis increase averaged 18.3° ± 13.6° in group 1 and 15.2° ± 9.0° in group 2. The benefit of anterior release was not statistically significant (p = 0.35). Although previous studies have suggested that thoracoscopic release improved correction compared to posterior surgery alone, the current study did not confirm this finding. Moreover, results of the current series showed that no significant benefit can be expected from AER in terms of sagittal plane improvement when the posteromedial translation technique is used, even in challenging hypokyphotic patients.

  4. Two-dimensional topological photonic systems

    Science.gov (United States)

    Sun, Xiao-Chen; He, Cheng; Liu, Xiao-Ping; Lu, Ming-Hui; Zhu, Shi-Ning; Chen, Yan-Feng

    2017-09-01

    The topological phase of matter, originally proposed and first demonstrated in fermionic electronic systems, has drawn considerable research attention in the past decades due to its robust transport of edge states and its potential with respect to future quantum information, communication, and computation. Recently, searching for such a unique material phase in bosonic systems has become a hot research topic worldwide. So far, many bosonic topological models and methods for realizing them have been discovered in photonic systems, acoustic systems, mechanical systems, etc. These discoveries have certainly yielded vast opportunities in designing material phases and related properties in the topological domain. In this review, we first focus on some of the representative photonic topological models and employ the underlying Dirac model to analyze the edge states and geometric phase. On the basis of these models, three common types of two-dimensional topological photonic systems are discussed: 1) photonic quantum Hall effect with broken time-reversal symmetry; 2) photonic topological insulator and the associated pseudo-time-reversal symmetry-protected mechanism; 3) time/space periodically modulated photonic Floquet topological insulator. Finally, we provide a summary and extension of this emerging field, including a brief introduction to the Weyl point in three-dimensional systems.

  5. Association of baseline knee sagittal dynamic joint stiffness during gait and 2-year patellofemoral cartilage damage worsening in knee osteoarthritis.

    Science.gov (United States)

    Chang, A H; Chmiel, J S; Almagor, O; Guermazi, A; Prasad, P V; Moisio, K C; Belisle, L; Zhang, Y; Hayes, K; Sharma, L

    2017-02-01

    Knee sagittal dynamic joint stiffness (DJS) describes the biomechanical interaction between change in external knee flexion moment and flexion angular excursion during gait. In theory, greater DJS may particularly stress the patellofemoral (PF) compartment and thereby contribute to PF osteoarthritis (OA) worsening. We hypothesized that greater baseline knee sagittal DJS is associated with PF cartilage damage worsening 2 years later. Participants all had OA in at least one knee. Knee kinematics and kinetics during gait were recorded using motion capture systems and force plates. Knee sagittal DJS was computed as the slope of the linear regression line for knee flexion moments vs angles during the loading response phase. Knee magnetic resonance imaging (MRI) scans were obtained at baseline and 2 years later. We assessed the association between baseline DJS and baseline-to-2-year PF cartilage damage worsening using logistic regression with generalized estimating equations (GEE). Our sample had 391 knees (204 persons): mean age 64.2 years (SD 10.0); body mass index (BMI) 28.4 kg/m 2 (5.7); 76.5% women. Baseline knee sagittal DJS was associated with baseline-to-2-year cartilage damage worsening in the lateral (OR = 5.35, 95% CI: 2.37-12.05) and any PF (OR = 2.99, 95% CI: 1.27-7.04) compartment. Individual components of baseline DJS (i.e., change in knee moment or angle) were not associated with subsequent PF disease worsening. Capturing the concomitant effect of knee kinetics and kinematics during gait, knee sagittal DJS is a potentially modifiable risk factor for PF disease worsening. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  6. Single photon emission computed tomography study of human pulmonary perfusion: preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Carratu, L; Sofia, M [Naples Univ. (Italy). Facolta di Medicina e Chirurgia; Salvatore, M; Muto, P; Ariemma, G [Istituto Nazionale per la Prevenzione, Lo Studio e La Cura dei Tumori Fondazione Pascale, Naples (Italy); Lopez-Majano, V [Cook County Hospital, Chicago, IL (USA). Nuclear Medicine Div.

    1984-02-01

    Single photon emission computed tomography (SPECT) was performed with /sup 99/Tcsup(m)-albumin macroaggregates to study human pulmonary perfusion in healthy subjects and patients with respiratory diseases such as chronic obstructive pulmonary disease (COPD) and lung neoplasms. The reconstructed SPECT data was displayed in coronal, transverse, sagittal plane sections and compared to conventional perfusion scans. The SPECT data gave more complicated anatomical information about the extent of damage and morphology of the pulmonary vascular bed. In healthy subjects and COPD patients, qualitative and quantitative assessment of pulmonary perfusion could be obtained from serial SPECT scans with respect to distribution and relative concentration of the injected radiopharmaceutical. Furthermore, SPECT of pulmonary perfusion has been useful in detecting the extent of damage to the pulmonary circulation. This is useful for the preoperative evaluation and staging of lung cancer.

  7. Advances in Photonics Design and Modeling for Nano- and Bio-photonics Applications

    DEFF Research Database (Denmark)

    Tanev, Stoyan

    2010-01-01

    In this invited paper we focus on the discussion of two recent unique applications of the Finite-Difference Time-Domain (FDTD) simulation method to the design and modeling of advanced nano- and bio-photonic problems. We will first discuss the application of a traditional formulation of the FDTD...

  8. Global analysis of sagittal spinal alignment in major deformities: correlation between lack of lumbar lordosis and flexion of the knee.

    Science.gov (United States)

    Obeid, Ibrahim; Hauger, Olivier; Aunoble, Stéphane; Bourghli, Anouar; Pellet, Nicolas; Vital, Jean-Marc

    2011-09-01

    It has become well recognised that sagittal balance of the spine is the result of an interaction between the spine and the pelvis. Knee flexion is considered to be the last compensatory mechanism in case of sagittal imbalance, but only few studies have insisted on the relationship between spino-pelvic parameters and lower extremity parameters. Correlation between the lack of lumbar lordosis and knee flexion has not yet been established. A retrospective study was carried out on 28 patients with major spinal deformities. The EOS system was used to measure spinal and pelvic parameters and the knee flexion angle; the lack of lumbar lordosis was calculated after prediction of lumbar lordosis with two different formulas. Correlation analysis between the different measured parameters was performed. Lumbar lordosis correlated with sacral slope (r = -0.71) and moderately with knee flexion angle (r = 0.42). Pelvic tilt correlated moderately with knee flexion angle (r = 0.55). Lack of lumbar lordosis correlated best with knee flexion angle (r = 0.72 and r = 0.63 using the two formulas, respectively). Knee flexion as a compensatory mechanism to sagittal imbalance was well correlated to the lack of lordosis and, depending on the importance of the former parameter, the best procedure to correct sagittal imbalance could be chosen.

  9. The performance of photons rainbow-colored energy experimental lecture schools in the kids' science museum of photons

    International Nuclear Information System (INIS)

    Hoshiya, Taiji; Sasaki, Kazuya; Nishikawa, Masahiro

    2008-01-01

    The Kansai Photon Science Institute (KPSI) of Japan Atomic Energy Agency (JAEA) has been promoting various activities of public understanding of science and technology, to be focused on the photon science, which is characterized by activities on science lectures and science events based on science and experiment classrooms, by utilizing the science museum of the JAEA (The Kids' Science Museum of Photons). In this phase, the KPSI extends systematically trial activities of the science museum to be as an experimental apparatus for studying on science and technology, including the program for promoting activities on public understanding of science and technology at the region. (author)

  10. Photon-Photon Collisions -- Past and Future

    International Nuclear Information System (INIS)

    Brodsky, Stanley J.

    2005-01-01

    I give a brief review of the history of photon-photon physics and a survey of its potential at future electron-positron colliders. Exclusive hadron production processes in photon-photon and electron-photon collisions provide important tests of QCD at the amplitude level, particularly as measures of hadron distribution amplitudes. There are also important high energy γγ and eγ tests of quantum chromodynamics, including the production of jets in photon-photon collisions, deeply virtual Compton scattering on a photon target, and leading-twist single-spin asymmetries for a photon polarized normal to a production plane. Since photons couple directly to all fundamental fields carrying the electromagnetic current including leptons, quarks, W's and supersymmetric particles, high energy γγ collisions will provide a comprehensive laboratory for Higgs production and exploring virtually every aspect of the Standard Model and its extensions. High energy back-scattered laser beams will thus greatly extend the range of physics of the International Linear Collider

  11. An interactive tool for CT volume rendering and sagittal plane-picking of the prostate for radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Jani, Ashesh B.; Pelizzari, Charles A.; Chen, George T.Y.; Grzezcszuk, Robert P.; Vijayakumar, Srinivasan

    1997-01-01

    Objective: Accurate and precise target volume and critical structure definition is a basic necessity in radiotherapy. The prostate, particularly the apex (an important potential site of recurrence in prostate cancer patients), is a challenging structure to define using any modality, including conventional axial CT. Invasive or expensive techniques, such as retrograde urethrography or MRI, could be avoided if localization of the prostate were possible using information already available on the planning CT. Our primary objective was to build a software tool to determine whether volume rendering and sagittal plane-picking, which are CT-based, noninvasive visualization techniques, were of utility in radiotherapy treatment planning for the prostate. Methods: Using AVS (Application Visualization System) on a Silicon Graphics Indigo 2 High Impact workstation, we have developed a tool that enables the clinician to efficiently navigate a CT volume and to use volume rendering and sagittal plane-picking to better define structures at any anatomic site. We applied the tool to the specific example of the prostate to compare the two visualization techniques with the current standard of axial CT. The prostate was defined on 80-slice CT scans (scanning thickness 4mm, pixel size 2mm x 2mm) of prostate cancer patients using axial CT images, volume-rendered CT images, and sagittal plane-picked images. Results: The navigation of the prostate using the different visualization techniques qualitatively demonstrated that the sagittal plane-picked images, and even more so the volume-rendered images, revealed the prostate (particularly the lower border) better in relationship to the surrounding regional anatomy (bladder, rectum, pelvis, and penile structures) than did the axial images. A quantitative comparison of the target volumes obtained by navigating using the different visualization techniques demonstrated that, when compared to the prostate volume defined on axial CT, a larger volume

  12. Quantum Dots in Photonic Crystal Waveguides

    DEFF Research Database (Denmark)

    Sollner, Immo Nathanael

    This Thesis is focused on the study of quantum electrodynamics in photonic crystal waveguides. We investigate the interplay between a single quantum dot and the fundamental mode of the photonic crystal waveguide. We demonstrate experimental coupling eciencies for the spontaneous emission...... into the mode exceeding 98% for emitters spectrally close to the band-edge of the waveguide mode. In addition we illustrate the broadband nature of the underlying eects, by obtaining coupling eciencies above 90% for quantum dots detuned from the band edge by as far as 20nm. These values are in good agreement...... with numerical simulations. Such a high coupling eciency implies that the system can be considered an articial 1D-atom, and we theoretically show that this system can generate strong photon-photon interaction, which is an essential functionality for deterministic optical quantum information processing. We...

  13. FY 2006 Infrared Photonics Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Anheier, Norman C.; Allen, Paul J.; Bernacki, Bruce E.; Ho, Nicolas; Krishnaswami, Kannan; Qiao, Hong (Amy); Schultz, John F.

    2006-12-28

    Research done by the Infrared Photonics team at Pacific Northwest National Laboratory (PNNL) is focused on developing miniaturized integrated optics and optical fiber processing methods for mid-wave infrared (MWIR) and long-wave infrared (LWIR) sensing applications by exploiting the unique optical and material properties of chalcogenide glass. PNNL has developed thin-film deposition capabilities, direct laser writing techniques, infrared photonic device demonstration, holographic optical element design and fabrication, photonic device modeling, and advanced optical metrology—all specific to chalcogenide glass. Chalcogenide infrared photonics provides a pathway to quantum cascade laser (QCL) transmitter miniaturization. The high output power, small size, and superb stability and modulation characteristics of QCLs make them amenable for integration as transmitters into ultra-sensitive, ultra-selective point sampling and remote short-range chemical sensors that are particularly useful for nuclear nonproliferation missions.

  14. Fractional decay of quantum dots in real photonic crystals

    DEFF Research Database (Denmark)

    Kristensen, Philip Trøst; Koenderink, A. Femius; Lodahl, Peter

    2008-01-01

    We show that fractional decay may be observable in experiments using quantum dots and photonic crystals with parameters that are currently achievable. We focus on the case of inverse opal photonic crystals and locate the position in the crystal where the effect is most pronounced. Furthermore, we...

  15. Photonic integrated circuits : a new approach to laser technology

    NARCIS (Netherlands)

    Piramidowicz, R.; Stopinski, S.T.; Lawniczuk, K.; Welikow, K.; Szczepanski, P.; Leijtens, X.J.M.; Smit, M.K.

    2012-01-01

    In this work a brief review on photonic integrated circuits (PICs) is presented with a specific focus on integrated lasers and amplifiers. The work presents the history of development of the integration technology in photonics and its comparison to microelectronics. The major part of the review is

  16. Simultaneous display of MRA and MPR in detecting vascular compression for trigeminal neuralgia or hemifacial spasm: comparison with oblique sagittal views of MRI

    International Nuclear Information System (INIS)

    Arbab, A.S.; Aoki, S.; Yoshikawa, T.; Kumagai, H.; Araki, T.; Nishiyama, Y.; Nagaseki, Y.; Nukui, H.

    2000-01-01

    A new technique, simultaneous display of magnetic resonance angiography (MRA) and multiplanar reconstruction (MPR), was performed by a workstation to identify the involved vessels in patients with trigeminal neuralgia (TN) or hemifacial spasm (HFS), and the results were compared with those of oblique sagittal MRI technique. Twelve patients with either HFS or TN were prospectively assessed by simultaneous display of MRA and MPR, and oblique sagittal techniques, to point out the neurovascular compression and to identify the involved vessels. Three-dimensional (3D) time-of-flight (TOF) spoiled gradient-echo (SPGR) images were acquired to create MRA and MPR. Oblique sagittal views were also created and displayed on films. A total of 15 vessels in 12 patients were identified as compressing vessels during surgery. Simultaneous display of MRA and MPR technique pointed out the presence of vessels at and/or around root entry/exit zone (REZ) in all 12 patients, but proper identification by the name of the individual vessel was correct in 13 of 15 cases. However, oblique sagittal technique indicated the presence of vessels at and/or around REZ in 11 patients, but only 8 of 14 vessels were correctly identified. Our new method, simultaneous display of MRA-MPR, facilitated correct identification of the involved vessels compared with the oblique sagittal view method. (orig.)

  17. Association of myelopathy scores with cervical sagittal balance and normalized spinal cord volume: analysis of 56 preoperative cases from the AOSpine North America Myelopathy study.

    Science.gov (United States)

    Smith, Justin S; Lafage, Virginie; Ryan, Devon J; Shaffrey, Christopher I; Schwab, Frank J; Patel, Alpesh A; Brodke, Darrel S; Arnold, Paul M; Riew, K Daniel; Traynelis, Vincent C; Radcliff, Kris; Vaccaro, Alexander R; Fehlings, Michael G; Ames, Christopher P

    2013-10-15

    Post hoc analysis of prospectively collected data. Development of methods to determine in vivo spinal cord dimensions and application to correlate preoperative alignment, myelopathy, and health-related quality-of-life scores in patients with cervical spondylotic myelopathy (CSM). CSM is the leading cause of spinal cord dysfunction. The association between cervical alignment, sagittal balance, and myelopathy has not been well characterized. This was a post hoc analysis of the prospective, multicenter AOSpine North America CSM study. Inclusion criteria for this study required preoperative cervical magnetic resonance imaging (MRI) and neutral sagittal cervical radiography. Techniques for MRI assessment of spinal cord dimensions were developed. Correlations between imaging and health-related quality-of-life scores were assessed. Fifty-six patients met inclusion criteria (mean age = 55.4 yr). The modified Japanese Orthopedic Association (mJOA) scores correlated with C2-C7 sagittal vertical axis (SVA) (r = -0.282, P = 0.035). Spinal cord volume correlated with cord length (r = 0.472, P balance (C2-C7 SVA) to myelopathy severity. We found a moderate negative correlation in kyphotic patients of cord volume and cross-sectional area to mJOA scores. The opposite (positive correlation) was found for lordotic patients, suggesting a relationship of cord volume to myelopathy that differs on the basis of sagittal alignment. It is interesting to note that sagittal balance but not kyphosis is tied to myelopathy score. Future work will correlate alignment changes to cord morphology changes and myelopathy outcomes. SUMMARY STATEMENTS: This is the first study to correlate sagittal balance (C2-C7 SVA) to myelopathy severity. We found a moderate negative correlation in kyphotic patients of cord volume and cross-sectional area to mJOA scores. The opposite (positive correlation) was found for lordotic patients, suggesting a relationship of cord volume to myelopathy that differs on the

  18. Influence of spinal sagittal alignment, body balance, muscle strength, and physical ability on falling of middle-aged and elderly males.

    Science.gov (United States)

    Imagama, Shiro; Ito, Zenya; Wakao, Norimitsu; Seki, Taisuke; Hirano, Kenichi; Muramoto, Akio; Sakai, Yoshihito; Matsuyama, Yukihiro; Hamajima, Nobuyuki; Ishiguro, Naoki; Hasegawa, Yukiharu

    2013-06-01

    Risk factors for falling in elderly people remain uncertain, and the effects of spinal factors and physical ability on body balance and falling have not been examined. The objective of this study was to investigate how factors such as spinal sagittal alignment, spinal range of motion, body balance, muscle strength, and gait speed influence falling in the prospective cohort study. The subjects were 100 males who underwent a basic health checkup. Balance, SpinalMouse(®) data, grip strength, back muscle strength, 10-m gait time, lumbar lateral standing radiographs, body mass index, and fall history over the previous year were examined. Platform measurements of balance included the distance of movement of the center of pressure (COP) per second (LNG/TIME), the envelopment area traced by movement of the COP (E AREA), and the LNG/E AREA ratio. The thoracic/lumbar angle ratio (T/L ratio) and sagittal vertical axis (SVA) were used as an index of sagittal balance. LNG/TIME and E AREA showed significant positive correlations with age, T/L ratio, SVA, and 10-m gait time; and significant negative correlations with lumbar lordosis angle, sacral inclination angle, grip strength and back muscle strength. Multiple regression analysis showed significant differences for LNG/TIME and E AREA with T/L ratio, SVA, lumbar lordosis angle and sacral inclination angle (R (2) = 0.399). Twelve subjects (12 %) had experienced a fall over the past year. Age, T/L ratio, SVA, lumbar lordosis angle, sacral inclination angle, grip strength, back muscle strength, 10-m gait time, height of the intervertebral disc, osteophyte formation in radiographs and LNG/E AREA differed significantly between fallers and non-fallers. The group with SVA > 40 mm (n = 18) had a significant higher number of subjects with a single fall (6 single fallers/18: p = 0.0075) and with multiple falls (4 multiple fallers/18: p = 0.0095). Good spinal sagittal alignment, muscle strength and 10-m gait speed improve body balance

  19. X-linked hypophosphatemic rickets and sagittal craniosynostosis: three patients requiring operative cranial expansion: case series and literature review.

    Science.gov (United States)

    Jaszczuk, Phillip; Rogers, Gary F; Guzman, Raphael; Proctor, Mark R

    2016-05-01

    A defect in a phosphate-regulating gene leads to the most common form of rickets: X-linked hypophosphatemic rickets (XLH) or vitamin D-resistant rickets (VDDR). XLH has been associated with craniosynostosis, the sagittal suture being the most commonly involved. We present three patients with rickets and symptomatic sagittal suture craniosynostosis all of whom presented late (>2 years of age). Two had a severe phenotype and papilledema, while the third presented with an osseous bulging near the anterior fontanel and experienced chronic headaches. All underwent successful cranial vault expansion. Rachitic patients with scaphocephaly should be screened for craniosynostosis.

  20. [Sagittal otolith morphology and the relationship between its mass and the age of Liza haematocheila in the Yangtze Estuary, China].

    Science.gov (United States)

    Ji, Yan; Zhao, Feng; Yang, Qin; Ma, Rong Rong; Yang, Gang; Zhang, Tao; Zhuang, Ping

    2018-03-01

    To examine the relationship of morphological characters of sagittal otolith and the age of Liza haematocheila in the Yangtze Estuary, we analyzed the morphological parameters of 324 pairs of otoliths extracted from 358 L. haematocheila specimens from the Yangtze Estuary in February to June of 2017. The results showed that sagittal otolith had rostrum, antirostrum and obvious central notch. The size and shape of sagittal otolith significantly changed with their growth, from regular melon seeds shape outline to long narrow leaf shape and increasing irregular wavy outline. The average density of sagittal otolith was 1.52 mg·mm -2 . The average rectangularity was 0.68. The length of sagittal otolith was 0.021%-0.047% of entire body length (BL), the width was 0.009%-0.021% of entire BL, and the mass was 0.045‰-0.731‰ of the entire body mass (BM). Otolith length (OL), otolith width (OW) and otolith mass (OM) were all significantly related to the BL, with the determination coefficient for OW and OM model being the highest (R 2 =0.928). The relationship between OM and BL was described best by exponential regression: OM=0.0009BL 1.8737 (R 2 =0.967). The relationships between OM and age (A), BL and A were well fitted by multinomial regressions, respectively: OM=2.9262A 2 +4.8437A+2.1894 (R 2 =0.847), BL=-3.2248A 2 +102.54A+38.373 (R 2 =0.858). In addition, OM was linearly correlated with A. The estimated otolith's ages from the model did not significantly variate from the real ages counting from annulus counts. Therefore, OM could be an effective parameter for the age estimation of L. haematocheila.

  1. Can a Single Sagittal Magnetic Resonance Imaging Slice Represent Whole Fatty Infiltration in Chronic Rotator Cuff Tears at the Supraspinatus?

    Science.gov (United States)

    Lee, Yong-Beom; Yang, Cheol-Jung; Li, Cheng Zhen; Zhuan, Zhong; Kwon, Seung-Cheol; Noh, Kyu-Cheol

    2018-03-01

    This study aimed to investigate whether fatty infiltration (FI) measured on a single sagittal magnetic resonance imaging (MRI) slice can represent FI of the whole supraspinatus muscle. This study retrospectively reviewed the MRIs of 106 patients (age 50-79 years) divided into three rotator cuff tear-size groups: medium, large, and massive. Fat mass and muscle mass on all T1-weighted sagittal MRI scans (FA and MA) were measured. Of the total MRI scans, the Y-view was defined as the most lateral image of the junction of the scapular spine with the scapular body on the oblique sagittal T1-weighted image. Fat mass and muscle mass seen on this Y-view single slice were recorded as F1 and M1, respectively. Fat mass and muscle mass were also assessed on MRI scans lateral and medial to the Y-view. The means of fat mass and muscle mass on these three slices were recorded as F3 and M3, respectively. Average FI ratios (fat mass/muscle mass) of the three assessment methods (F1/M1, FA/MA, and F3/M3) were compared. Intraclass correlation coefficients (ICCs) were calculated for inter- and intraobserver reliability. ICCs showed higher reliability (> 0.8) for all measurements. F1/M1 values were not statistically different from FA/MA and F3/M3 values ( p > 0.05), except in males with medium and large tears. F3/M3 and FA/MA were not statistically different. The difference between F1/M1 and FA/MA did not exceed 2%. A single sagittal MRI slice can represent the whole FI in chronic rotator cuff tears, except in some patient groups. We recommend measurement of FI using a single sagittal MRI slice, given the effort required for repeated measurements.

  2. Hadron production in photon-photon collisions

    International Nuclear Information System (INIS)

    Pandita, P.N.; Singh, Y.

    1976-01-01

    We analyze deep-inelastic photon-photon collisions via the two-photon mechanism in electron-positron (-electron) colliding beams in a form especially suitable for experimental analysis. It is shown that by a helicity analysis similar to that used in electroproduction experiments, we can separate five of the eight structure functions describing the process γ* + γ* → hadrons. The helicity cross sections for this process and for the process with one real photon (inelastic electron-photon scattering) are related to structure functions, and are evaluated using quark light-cone algebra. There are anomalous contributions to the structure functions for the inelastic electron-photon scattering which arise both in parton as well as generalized vector-meson-dominance models. This suggests a connection between these two types of models for photon-photon scattering. Further, we use vector-meson dominance to construct a sum rule for sigma/sub gamma//sub gamma/ /sub arrow-right/ from which it is estimated that roughly 20% of the cross section should be built up from higher-mass vector states. Using a spectral representation for the total transverse cross section, and the ''aligned-jet'' vector-dominance model we achieve a connection, via a ''correspondence principle,'' with the parton model for the hadron multiplicities in photon-photon collisions. We also comment on inclusive pion multiplicities and the approach to scaling for photon-photon processes in the light-cone algebra

  3. Results from the solar hidden photon search (SHIPS)

    International Nuclear Information System (INIS)

    Schwarz, Matthias; Schneide, Magnus; Susol, Jaroslaw; Wiedemann, Guenter; Redondo, Javier

    2015-02-01

    We present the results of a search for transversely polarised hidden photons (HPs) with ∝3 eV energies emitted from the Sun. These hypothetical particles, known also as paraphotons or dark sector photons, are theoretically well motivated for example by string theory inspired extensions of the Standard Model. Solar HPs of sub-eV mass can convert into photons of the same energy (photon<->HP oscillations are similar to neutrino flavour oscillations). At SHIPS this would take place inside a long light-tight high-vacuum tube, which tracks the Sun. The generated photons would then be focused into a low-noise photomultiplier at the far end of the tube. Our analysis of 330 h of data (and 330 h of background characterisation) reveals no signal of photons from solar hidden photon conversion. We estimate the rate of newly generated photons due to this conversion to be smaller than 25 mHz/m 2 at the 95%C.L. Using this and a recent model of solar HP emission, we set stringent constraints on χ, the coupling constant between HPs and photons, as a function of the HP mass.

  4. Results from the Solar Hidden Photon Search (SHIPS)

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, Matthias; Schneide, Magnus; Susol, Jaroslaw; Wiedemann, Günter [Hamburger Sternwarte, Gojenbergsweg 112, D-21029 Hamburg (Germany); Knabbe, Ernst-Axel; Lindner, Axel; Ringwald, Andreas [Deutsches Elektronen-Synchrotron DESY, Notkestraße 85, D-22607 Hamburg (Germany); Redondo, Javier, E-mail: mschwarz@hs.uni-hamburg.de, E-mail: ernst-axel.knabbe@desy.de, E-mail: Axel-lindner@desy.de, E-mail: jredondo@unizar.es, E-mail: Andreas.Ringwald@desy.de, E-mail: mschneide@hs.uni-hamburg.de, E-mail: jsusol@hs.uni-hamburg.de, E-mail: gwiedemann@hs.uni-hamburg.de [Departamento de Física Teórica, Universidad de Zaragoza, Pedro Cerbuna 12, E-50009, Zaragoza (Spain)

    2015-08-01

    We present the results of a search for transversely polarised hidden photons (HPs) with ∼ 3 eV energies emitted from the Sun. These hypothetical particles, known also as paraphotons or dark sector photons, are theoretically well motivated for example by string theory inspired extensions of the Standard Model. Solar HPs of sub-eV mass can convert into photons of the same energy (photon ↔ HP oscillations are similar to neutrino flavour oscillations). At SHIPS this would take place inside a long light-tight high-vacuum tube, which tracks the Sun. The generated photons would then be focused into a low-noise photomultiplier at the far end of the tube. Our analysis of 330 h of data (and 330 h of background characterisation) reveals no signal of photons from solar hidden photon conversion. We estimate the rate of newly generated photons due to this conversion to be smaller than 25 mHz/m{sup 2} at the 95% C.L . Using this and a recent model of solar HP emission, we set stringent constraints on χ, the coupling constant between HPs and photons, as a function of the HP mass.

  5. Results from the solar hidden photon search (SHIPS)

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, Matthias; Schneide, Magnus; Susol, Jaroslaw; Wiedemann, Guenter [Hamburg Univ. (Germany). Sternwarte; Knabbe, Ernst-Axel; Lindner, Axel; Ringwald, Andreas [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Redondo, Javier [Zaragoza Univ. (Spain). Dept. de Fisica Teorica; Max-Planck-Institut fuer Physik, Muenchen (Germany)

    2015-02-15

    We present the results of a search for transversely polarised hidden photons (HPs) with ∝3 eV energies emitted from the Sun. These hypothetical particles, known also as paraphotons or dark sector photons, are theoretically well motivated for example by string theory inspired extensions of the Standard Model. Solar HPs of sub-eV mass can convert into photons of the same energy (photon<->HP oscillations are similar to neutrino flavour oscillations). At SHIPS this would take place inside a long light-tight high-vacuum tube, which tracks the Sun. The generated photons would then be focused into a low-noise photomultiplier at the far end of the tube. Our analysis of 330 h of data (and 330 h of background characterisation) reveals no signal of photons from solar hidden photon conversion. We estimate the rate of newly generated photons due to this conversion to be smaller than 25 mHz/m{sup 2} at the 95%C.L. Using this and a recent model of solar HP emission, we set stringent constraints on χ, the coupling constant between HPs and photons, as a function of the HP mass.

  6. Results from the Solar Hidden Photon Search (SHIPS)

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, Matthias [Hamburger Sternwarte, Gojenbergsweg 112, D-21029 Hamburg (Germany); Knabbe, Ernst-Axel; Lindner, Axel [Deutsches Elektronen-Synchrotron DESY, Notkestraße 85, D-22607 Hamburg (Germany); Redondo, Javier [Departamento de Física Teórica, Universidad de Zaragoza, Pedro Cerbuna 12, E-50009, Zaragoza (Spain); Max-Planck-Institut für Physik (Werner-Heisenberg-Institut), Föhringer Ring 6, D-80805 München (Germany); Ringwald, Andreas [Deutsches Elektronen-Synchrotron DESY, Notkestraße 85, D-22607 Hamburg (Germany); Schneide, Magnus; Susol, Jaroslaw; Wiedemann, Günter [Hamburger Sternwarte, Gojenbergsweg 112, D-21029 Hamburg (Germany)

    2015-08-07

    We present the results of a search for transversely polarised hidden photons (HPs) with ∼3 eV energies emitted from the Sun. These hypothetical particles, known also as paraphotons or dark sector photons, are theoretically well motivated for example by string theory inspired extensions of the Standard Model. Solar HPs of sub-eV mass can convert into photons of the same energy (photon ↔ HP oscillations are similar to neutrino flavour oscillations). At SHIPS this would take place inside a long light-tight high-vacuum tube, which tracks the Sun. The generated photons would then be focused into a low-noise photomultiplier at the far end of the tube. Our analysis of 330 h of data (and 330 h of background characterisation) reveals no signal of photons from solar hidden photon conversion. We estimate the rate of newly generated photons due to this conversion to be smaller than 25 mHz/m{sup 2} at the 95% C.L. Using this and a recent model of solar HP emission, we set stringent constraints on χ, the coupling constant between HPs and photons, as a function of the HP mass.

  7. Long-term Clinical and Radiographic Outcomes of Pedicle Subtraction Osteotomy for Fixed Sagittal Imbalance: Does Level of Proximal Fusion Affect the Outcome? Minimum 5-Year Follow-up.

    Science.gov (United States)

    Yagi, Mitsuru; King, Akilah B; Cunningham, Matthew E; Boachie-Adjei, Oheneba

    2013-03-01

    Retrospective case series of surgically treated adult patients with fixed sagittal imbalance. To assess clinical and radiographic changes after pedicle subtraction osteotomy (PSO) to treat adult fixed sagittal imbalance. Although recent reports have shown favorable clinical outcomes for PSO, few reports have published long-term follow-up outcomes. It is also unknown whether long-term outcomes are correlated with the level of proximal fusion and the radiographic changes that are observed after PSO. We reviewed the charts, X-rays, and postoperative SRS-22 and Oswestry Disability Index (ODI) scores of 32 adult patients who presented with fixed sagittal imbalance and were treated with lumbar PSO. Long fusions were defined as those proximal to T6, and short fusions were defined as those below T8. Measured radiographic parameters included thoracic kyphosis, lumbar lordosis (LL), sacral slope, pelvic incidence, and sagittal balance (SVA). Statistical analysis included Student t test and chi-square test. A p value of imbalance, PSO provided good sagittal balance and maintained favorable clinical outcomes in both the short and long fusion groups despite a slight decrease in the SVA and a high complication rate. The data suggest that the loss of sagittal balance may be attributed to increase global and junctional kyphosis in short fusion groups, and should be monitored for long-term outcomes. Particular attention should be paid to the long-term deterioration of the SVA in adults who present with fixed sagittal imbalance after PSO. Copyright © 2013 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  8. Photons, photon jets and dark photons at 750 GeV and beyond

    International Nuclear Information System (INIS)

    Dasgupta, Basudeb; Kopp, Joachim

    2016-03-01

    In new physics searches involving photons at the LHC, one challenge is to distinguish scenarios with isolated photons from models leading to ''photon jets''. For instance, in the context of the 750 GeV diphoton excess, it was pointed out that a true diphoton resonance S → γγ can be mimicked by a process of the form pp → S → aa → 4γ, where S is a new scalar with a mass of 750 GeV and a is a light pseudoscalar decaying to two collinear photons. Photon jets can be distinguished from isolated photons by exploiting the fact that a large fraction of photons convert to an e + e - pair inside the inner detector. In this note, we quantify this discrimination power, and we study how the sensitivity of future searches differs for photon jets compared to isolated photons. We also investigate how our results depend on the lifetime of the particle(s) decaying to the photon jet. Finally, we discuss the extension to S → A'A' → e + e - e + e - , where there are no photons at all but the dark photon A' decays to e + e - pairs. Our results will be useful in future studies of the putative 750 GeV signal, but also more generally in any new physics search involving hard photons.

  9. Knee joint passive stiffness and moment in sagittal and frontal planes markedly increase with compression.

    Science.gov (United States)

    Marouane, H; Shirazi-Adl, A; Adouni, M

    2015-01-01

    Knee joints are subject to large compression forces in daily activities. Due to artefact moments and instability under large compression loads, biomechanical studies impose additional constraints to circumvent the compression position-dependency in response. To quantify the effect of compression on passive knee moment resistance and stiffness, two validated finite element models of the tibiofemoral (TF) joint, one refined with depth-dependent fibril-reinforced cartilage and the other less refined with homogeneous isotropic cartilage, are used. The unconstrained TF joint response in sagittal and frontal planes is investigated at different flexion angles (0°, 15°, 30° and 45°) up to 1800 N compression preloads. The compression is applied at a novel joint mechanical balance point (MBP) identified as a point at which the compression does not cause any coupled rotations in sagittal and frontal planes. The MBP of the unconstrained joint is located at the lateral plateau in small compressions and shifts medially towards the inter-compartmental area at larger compression forces. The compression force substantially increases the joint moment-bearing capacities and instantaneous angular rigidities in both frontal and sagittal planes. The varus-valgus laxities diminish with compression preloads despite concomitant substantial reductions in collateral ligament forces. While the angular rigidity would enhance the joint stability, the augmented passive moment resistance under compression preloads plays a role in supporting external moments and should as such be considered in the knee joint musculoskeletal models.

  10. Inverse photon-photon processes

    International Nuclear Information System (INIS)

    Carimalo, C.; Crozon, M.; Kesler, P.; Parisi, J.

    1981-12-01

    We here consider inverse photon-photon processes, i.e. AB → γγX (where A, B are hadrons, in particular protons or antiprotons), at high energies. As regards the production of a γγ continuum, we show that, under specific conditions the study of such processes might provide some information on the subprocess gg γγ, involving a quark box. It is also suggested to use those processes in order to systematically look for heavy C = + structures (quarkonium states, gluonia, etc.) showing up in the γγ channel. Inverse photon-photon processes might thus become a new and fertile area of investigation in high-energy physics, provided the difficult problem of discriminating between direct photons and indirect ones can be handled in a satisfactory way

  11. Sectional anatomy of the fetal brain in uterus at term on the sagittal plane

    Directory of Open Access Journals (Sweden)

    Fan-Zhen Kong

    2011-06-01

    Conclusion: Through the comparison study between sagittal sections and corresponding MRI of fetal brain at term, we could obtain morphological anatomic structures and MRI of fetal brain, providing morphological demonstration of the intrauterine development of fetal brain and auxiliary diagnosis of ultrasound and MRI in pregnant woman.

  12. Photon-photon collisions

    International Nuclear Information System (INIS)

    Burke, D.L.

    1982-10-01

    Studies of photon-photon collisions are reviewed with particular emphasis on new results reported to this conference. These include results on light meson spectroscopy and deep inelastic e#betta# scattering. Considerable work has now been accumulated on resonance production by #betta##betta# collisions. Preliminary high statistics studies of the photon structure function F 2 /sup #betta#/(x,Q 2 ) are given and comments are made on the problems that remain to be solved

  13. Photon-photon collisions

    International Nuclear Information System (INIS)

    Haissinski, J.

    1986-06-01

    The discussions presented in this paper deal with the following points: distinctive features of gamma-gamma collisions; related processes; photon-photon elastic scattering in the continuum and γγ →gg; total cross section; γγ → V 1 V 2 (V=vector meson); radiative width measurements and light meson spectroscopy; exclusive channels at large /t/; jets and inclusive particle distribution in γγ collisions; and, the photon structure function F γ 2

  14. Effect of Long Term Oral Warfarin Sodium Treatment on Bone Mineral Density Scores and Spinal Sagittal Alignment

    Directory of Open Access Journals (Sweden)

    Kamil Eyvazov

    2016-04-01

    Full Text Available Objective: The aim of this study was to investigate the effect of long term oral warfarin sodium treatment on bone mineral density (BMD and spinal sagittal alignment. Materials and Methods: Sixty four participants were enrolled for this retrospective study. Participants were divided into two groups-participants who had taken warfarin sodium for at least two years (n=33 and participants who had never taken warfarin sodium (n=31. All of the individuals were evaluated at the same center. Dual X-ray absorptiometry (DXA was used for measuring BMD. Whole spine x-rays were obtained for sagittal assessment and the following parameters were measured: Cervical lordosis, thoracic kyphosis, lumbar lordosis, pelvic incidence, pelvic tilt, sacral slope and sagittal vertical axis (SVA. Results: The mean BMD value was significantly higher in participants who had not taken warfarin sodium compared to participants who had taken warfarin sodium. The differences between the average values were 0.1552 g/cm2 in BMD; 2.1 in T scores; 1.4 in Z scores. On the radiological evaluation of the spine, cervical lordosis was 7.1 degrees lower, lumbar lordosis was 4.7 degrees lower and thoracic kyphosis was 5.3 degrees higher in the patients using drug. C7 plumb line was interchanged forward in the patients using drug. Conclusions: This study shows that warfarin sodium use worsens bone quality in the lumbar region and does not affect bone quality in the femoral region. Furthermore, warfarin sodium use also reduces physiological lordosis and enhances thoracic kyphosis. Consequences of these changes are the likely cause of sagittal spinal anterior imbalance. Long-term oral warfarin sodium use affect bone mineral density and spinal alignment. Our conclusion about giving clear message and show exactly mechanism we need prospective randomized multicentre studies in future. We strongly believe this study will be pioneer for future researches.

  15. FY 2004 Infrared Photonics Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Anheier, Norman C.; Allen, Paul J.; Keller, Paul E.; Bennett, Wendy D.; Martin, Peter M.; Johnson, Bradley R.; Sundaram, S. K.; Riley, Brian J.; Martinez, James E.; Qiao, Hong (Amy); Schultz, John F.

    2004-10-01

    Research done by the Infrared Photonics team at PNNL is focused on developing miniaturized integrated optics for the MWIR and LWIR by exploiting the unique optical and material properties of chalcogenide glass. PNNL has developed thin film deposition capabilities, direct-laser writing techniques, IR photonic device demonstration, holographic optical element design and fabrication, photonic device modeling, and advanced optical metrology - all specific to chalcogenide glass. Chalcogenide infrared photonics provides a pathway to Quantum Cascade Laser (QCL) transmitter miniaturization. QCLs provide a viable infrared laser source for a new class of laser transmitters capable of meeting the performance requirements for a variety of national security sensing applications. The high output power, small size, and superb stability and modulation characteristics of QCLs make them amenable for integration as transmitters into ultra-sensitive, ultra-selective point sampling and remote short-range chemical sensors that are particularly useful for nuclear nonproliferation missions.

  16. 1975 Memorial Award Paper. Image generation and display techniques for CT scan data. Thin transverse and reconstructed coronal and sagittal planes.

    Science.gov (United States)

    Glenn, W V; Johnston, R J; Morton, P E; Dwyer, S J

    1975-01-01

    The various limitations to computerized axial tomographic (CT) interpretation are due in part to the 8-13 mm standard tissue plane thickness and in part to the absence of alternative planes of view, such as coronal or sagittal images. This paper describes a method for gathering multiple overlapped 8 mm transverse sections, subjecting these data to a deconvolution process, and then displaying thin (1 mm) transverse as well as reconstructed coronal and sagittal CT images. Verification of the deconvolution technique with phantom experiments is described. Application of the phantom results to human post mortem CT scan data illustrates this method's faithful reconstruction of coronal and sagittal tissue densities when correlated with actual specimen photographs of a sectioned brain. A special CT procedure, limited basal overlap scanning, is proposed for use on current first generation CT scanners without hardware modification.

  17. The influence of heel height on sagittal plane knee kinematics during landing tasks in recreationally active and athletic collegiate females.

    Science.gov (United States)

    Lindenberg, Kelly M; Carcia, Christopher R; Phelps, Amy L; Martin, Robroy L; Burrows, Anne M

    2011-09-01

    To determine if heel height alters sagittal plane knee kinematics when landing from a forward hop or drop landing. Knee angles close to extension during landing are theorized to increase ACL injury risk in female athletes. Fifty collegiate females performed two single-limb landing tasks while wearing heel lifts of three different sizes (0, 12 & 24 mm) attached to the bottom of a sneaker. Using an electrogoniometer, sagittal plane kinematics (initial contact [KA(IC)], peak flexion [KA(Peak)], and rate of excursion [RE]) were examined. Repeated measures ANOVAs were used to determine the influence of heel height on the dependent measures. Forward hop task- KA(IC) with 0 mm, 12 mm, and 24 mm lifts were 8.88±6.5, 9.38±5.8 and 11.28±7.0, respectively. Significant differences were noted between 0 and 24 mm lift (psneaker significantly alters sagittal plane knee kinematics upon landing from a unilateral forward hop but not from a drop jump.

  18. The nature of light what is a photon?

    CERN Document Server

    Roychoudhuri, Chandra; Creath, Kathy

    2008-01-01

    Focusing on the unresolved debate between Newton and Huygens from 300 years ago, The Nature of Light: What is a Photon? discusses the reality behind enigmatic photons. It explores the fundamental issues pertaining to light that still exist today. Gathering contributions from globally recognized specialists in electrodynamics and quantum optics, the book begins by clearly presenting the mainstream view of the nature of light and photons. It then provides a new and challenging scientific epistemology that explains how to overcome the prevailing paradoxes and confusions arising from the accepted definition of a photon as a monochromatic Fourier mode of the vacuum. The book concludes with an array of experiments that demonstrate the innovative thinking needed to examine the wave-particle duality of photons. Looking at photons from both mainstream and out-of-box viewpoints, this volume is sure to inspire the next generation of quantum optics scientists and engineers to go beyond the Copenhagen interpretat...

  19. Two-dimensional 'photon fluid': effective photon-photon interaction and physical realizations

    International Nuclear Information System (INIS)

    Chiao, R Y; Hansson, T H; Leinaas, J M; Viefers, S

    2004-01-01

    We describe a recently developed effective theory for atom-mediated photon-photon interactions in a two-dimensional 'photon fluid' confined to a Fabry-Perot resonator. The photons in the lowest longitudinal cavity mode will appear as massive bosons interacting via a renormalized delta-function potential with a strength determined by physical parameters such as the density of atoms and the detuning of the photons relative to the resonance frequency of the atoms. We discuss novel quantum phenomena for photons, such as Bose-Einstein condensation and bound state formation, as well as possible experimental scenarios based on Rydberg atoms in a microwave cavity, or alkali atoms in an optical cavity

  20. ITMO Photonics: center of excellence

    Science.gov (United States)

    Voznesenskaya, Anna; Bougrov, Vladislav; Kozlov, Sergey; Vasilev, Vladimir

    2016-09-01

    ITMO University, the leading Russian center in photonics research and education, has the mission to train highlyqualified competitive professionals able to act in conditions of fast-changing world. This paradigm is implemented through creation of a strategic academic unit ITMO Photonics, the center of excellence concentrating organizational, scientific, educational, financial, laboratory and human resources. This Center has the following features: dissemination of breakthrough scientific results in photonics such as advanced photonic materials, ultrafast optical and quantum information, laser physics, engineering and technologies, into undergraduate and graduate educational programs through including special modules into the curricula and considerable student's research and internships; transformation of the educational process in accordance with the best international educational practices, presence in the global education market in the form of joint educational programs with leading universities, i.e. those being included in the network programs of international scientific cooperation, and international accreditation of educational programs; development of mechanisms for the commercialization of innovative products - results of scientific research; securing financial sustainability of research in the field of photonics of informationcommunication systems via funding increase and the diversification of funding sources. Along with focusing on the research promotion, the Center is involved in science popularization through such projects as career guidance for high school students; interaction between student's chapters of international optical societies; invited lectures of World-famous experts in photonics; short educational programs in optics, photonics and light engineering for international students; contests, Olympics and grants for talented young researchers; social events; interactive demonstrations.

  1. Clinical and radiological outcomes after treatment of sagittal fracture of mandibular condyle (SFMC) by using occlusal splint in children.

    Science.gov (United States)

    Liu, Chang-Kui; Meng, Fan-Wen; Tan, Xin-Ying; Xu, Juan; Liu, Hua-Wei; Liu, San-Xia; Huang, Hai-Tao; Yan, Rong-Zeng; Hu, Min; Hu, Kai-Jin

    2014-02-01

    This study was designed to investigate the effects of occlusal splints in the treatment of sagittal fractures of the mandibular condyle in children. From January 1995 to December 2011, 37 sagittal fractures of the mandibular condyle in 30 patients aged 4-8 years old were included in this study. All the patients were treated with 1-2mm occlusal splints in the molar region. The mouths of the patients were kept slightly open by the occlusal splints for 3-6 months, and we reviewed the clinical and radiological remodelling of the affected condyles after treatment. Excellent (n=20) and good (n=10) clinical outcomes were achieved with full radiological remodelling seen in 19 and partial remodelling in 11. Treatment with occlusal splints is effective in delivering good results and function with minimal morbidity in children with sagittal fractures of the condyle, while permitting ongoing remodelling and growth in the short term. Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Sagittal MR findings of L5 spondylolysis : changes of spinal canal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Cheol; Choi, Woo Suk; Kim, Eui Jong; Ryu, Kyung Nam; Oh, Joo Hyeong; Kim, Ihn Sub; Yoon, Yup [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1997-07-01

    To evaluate changes in the spinal canal in cases of L5 spondylolysis, as seen on sagittal MR images. We retrospectively analysed the MR findings of 27 patients suffering from L5 spondylolysis without spondylolisthesis and compared them with 100 control subjects. Spondylolysis had been confirmed by conventional radiography. On midsagittal MR images, sagittal canal ratio (SCR) was defined as midsagittal canal diameter at L5 devided by that at L1. We analysed the frequency of posterior epidural fat deposition(posterior epidural fat between the posterior margin of the dural sac and the anterior cortical margin of the spinous process on the midsagittal line), and compared this with the frequency in 100 control subjects. Mean SCR value in 27 patients with L5 spondylolysis(1.22) was significantly greater than 100 control subjects(0.96, p<0.001). Mean SCR value in 17 patients with L5 spondylolysis and posterior epidural fat deposition(1.27) was significantly higher than in nine control subjects with posterior epidural fat deposition(0.97). Posterior epidural fat deposition was more frequently indentified in patients with L5 spondylolysis(63%) than in control subjects(9%). The possibility of L5 spondylolysis is suggested when on midsaggital MR imaging, the anteroposterior diameter of the L5 spinal canal is seen to be widened and posterior epidural fat deposition is noted.

  3. Sagittal MR findings of L5 spondylolysis : changes of spinal canal

    International Nuclear Information System (INIS)

    Kim, Hyun Cheol; Choi, Woo Suk; Kim, Eui Jong; Ryu, Kyung Nam; Oh, Joo Hyeong; Kim, Ihn Sub; Yoon, Yup

    1997-01-01

    To evaluate changes in the spinal canal in cases of L5 spondylolysis, as seen on sagittal MR images. We retrospectively analysed the MR findings of 27 patients suffering from L5 spondylolysis without spondylolisthesis and compared them with 100 control subjects. Spondylolysis had been confirmed by conventional radiography. On midsagittal MR images, sagittal canal ratio (SCR) was defined as midsagittal canal diameter at L5 devided by that at L1. We analysed the frequency of posterior epidural fat deposition(posterior epidural fat between the posterior margin of the dural sac and the anterior cortical margin of the spinous process on the midsagittal line), and compared this with the frequency in 100 control subjects. Mean SCR value in 27 patients with L5 spondylolysis(1.22) was significantly greater than 100 control subjects(0.96, p<0.001). Mean SCR value in 17 patients with L5 spondylolysis and posterior epidural fat deposition(1.27) was significantly higher than in nine control subjects with posterior epidural fat deposition(0.97). Posterior epidural fat deposition was more frequently indentified in patients with L5 spondylolysis(63%) than in control subjects(9%). The possibility of L5 spondylolysis is suggested when on midsaggital MR imaging, the anteroposterior diameter of the L5 spinal canal is seen to be widened and posterior epidural fat deposition is noted

  4. Preliminary results of anterior lumbar interbody fusion, anterior column realignment for the treatment of sagittal malalignment.

    Science.gov (United States)

    Hosseini, Pooria; Mundis, Gregory M; Eastlack, Robert K; Bagheri, Ramin; Vargas, Enrique; Tran, Stacie; Akbarnia, Behrooz A

    2017-12-01

    OBJECTIVE Sagittal malalignment decreases patients' quality of life and may require surgical correction to achieve realignment goals. High-risk posterior-based osteotomy techniques are the current standard treatment for addressing sagittal malalignment. More recently, anterior lumbar interbody fusion, anterior column realignment (ALIF ACR) has been introduced as an alternative for correction of sagittal deformity. The objective of this paper was to report clinical and radiographic results for patients treated using the ALIF-ACR technique. METHODS A retrospective study of 39 patients treated with ALIF ACR was performed. Patient demographics, operative details, radiographic parameters, neurological assessments, outcome measures, and preoperative, postoperative, and mean 1-year follow-up complications were studied. RESULTS The patient population comprised 39 patients (27 females and 12 males) with a mean follow-up of 13.3 ± 4.7 months, mean age of 66.1 ± 11.6 years, and mean body mass index of 27.3 ± 6.2 kg/m 2 . The mean number of ALIF levels treated was 1.5 ± 0.5. Thirty-three (84.6%) of 39 patients underwent posterior spinal fixation and 33 (84.6%) of 39 underwent posterior column osteotomy, of which 20 (60.6%) of 33 procedures were performed at the level of the ALIF ACR. Pelvic tilt, sacral slope, and pelvic incidence were not statistically significantly different between the preoperative and postoperative periods and between the preoperative and 1-year follow-up periods (except for PT between the preoperative and 1-year follow-up, p = 0.018). Sagittal vertical axis, T-1 spinopelvic inclination, lumbar lordosis, pelvic incidence-lumbar lordosis mismatch, intradiscal angle, and motion segment angle all improved from the preoperative to postoperative period and the preoperative to 1-year follow-up (p < 0.05). The changes in motion segment angle and intradiscal angle achieved in the ALIF-ACR group without osteotomy compared with the ALIF-ACR group with osteotomy

  5. Jet and hadron production in photon-photon collisions

    OpenAIRE

    Soldner-Rembold, Stefan

    1999-01-01

    Di-jet and inclusive charged hadron production cross-sections measured in photon-photon collisions by OPAL are compared to NLO pQCD calculations. Jet shapes measured in photon-photon scattering by OPAL, in deep-inelastic ep scattering by H1 and in photon-proton scattering by ZEUS are shown to be consistent in similar kinematic ranges. New results from TOPAZ on prompt photon production in photon-photon interactions are presented.

  6. Single photon sources with single semiconductor quantum dots

    Science.gov (United States)

    Shan, Guang-Cun; Yin, Zhang-Qi; Shek, Chan Hung; Huang, Wei

    2014-04-01

    In this contribution, we briefly recall the basic concepts of quantum optics and properties of semiconductor quantum dot (QD) which are necessary to the understanding of the physics of single-photon generation with single QDs. Firstly, we address the theory of quantum emitter-cavity system, the fluorescence and optical properties of semiconductor QDs, and the photon statistics as well as optical properties of the QDs. We then review the localization of single semiconductor QDs in quantum confined optical microcavity systems to achieve their overall optical properties and performances in terms of strong coupling regime, efficiency, directionality, and polarization control. Furthermore, we will discuss the recent progress on the fabrication of single photon sources, and various approaches for embedding single QDs into microcavities or photonic crystal nanocavities and show how to extend the wavelength range. We focus in particular on new generations of electrically driven QD single photon source leading to high repetition rates, strong coupling regime, and high collection efficiencies at elevated temperature operation. Besides, new developments of room temperature single photon emission in the strong coupling regime are reviewed. The generation of indistinguishable photons and remaining challenges for practical single-photon sources are also discussed.

  7. Photons, photon jets, and dark photons at 750 GeV and beyond.

    Science.gov (United States)

    Dasgupta, Basudeb; Kopp, Joachim; Schwaller, Pedro

    2016-01-01

    In new physics searches involving photons at the LHC, one challenge is to distinguish scenarios with isolated photons from models leading to "photon jets". For instance, in the context of the 750 GeV diphoton excess, it was pointed out that a true diphoton resonance [Formula: see text] can be mimicked by a process of the form [Formula: see text], where S is a new scalar with a mass of 750 GeV and a is a light pseudoscalar decaying to two collinear photons. Photon jets can be distinguished from isolated photons by exploiting the fact that a large fraction of photons convert to an [Formula: see text] pair inside the inner detector. In this note, we quantify this discrimination power, and we study how the sensitivity of future searches differs for photon jets compared to isolated photons. We also investigate how our results depend on the lifetime of the particle(s) decaying to the photon jet. Finally, we discuss the extension to [Formula: see text], where there are no photons at all but the dark photon [Formula: see text] decays to [Formula: see text] pairs. Our results will be useful in future studies of the putative 750 GeV signal, but also more generally in any new physics search involving hard photons.

  8. Two-Photon Fluorescence Microscopy Developed for Microgravity Fluid Physics

    Science.gov (United States)

    Fischer, David G.; Zimmerli, Gregory A.; Asipauskas, Marius

    2004-01-01

    Recent research efforts within the Microgravity Fluid Physics Branch of the NASA Glenn Research Center have necessitated the development of a microscope capable of high-resolution, three-dimensional imaging of intracellular structure and tissue morphology. Standard optical microscopy works well for thin samples, but it does not allow the imaging of thick samples because of severe degradation caused by out-of-focus object structure. Confocal microscopy, which is a laser-based scanning microscopy, provides improved three-dimensional imaging and true optical sectioning by excluding the out-of-focus light. However, in confocal microscopy, out-of-focus object structure is still illuminated by the incoming beam, which can lead to substantial photo-bleaching. In addition, confocal microscopy is plagued by limited penetration depth, signal loss due to the presence of a confocal pinhole, and the possibility of live-cell damage. Two-photon microscopy is a novel form of laser-based scanning microscopy that allows three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon microscopy, it utilizes the nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption because of the nonlinear (i.e., quadratic) electric field dependence, so an ultrafast pulsed laser source must typically be employed. On the other hand, this stringent energy density requirement effectively localizes fluorophore excitation to the focal volume. Consequently, two-photon microscopy provides optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction in photo-damage because of the longer excitation wavelength, a reduction in background fluorescence, and a 4 increase in penetration depth over confocal methods because of the reduction in Rayleigh scattering.

  9. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    Science.gov (United States)

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  10. submitter Light Extraction From Scintillating Crystals Enhanced by Photonic Crystal Structures Patterned by Focused Ion Beam

    CERN Document Server

    Modrzynski, Pawel; Knapitsch, Arno; Kunicki, Piotr; Lecoq, Paul; Moczala, Magdalena; Papakonstantinou, Ioannis; Auffray, Etiennette

    2016-01-01

    Photonic Crystals (PhC)” have been used in a variety of fields as a structure for improving the light extraction efficiency from materials with high index of refraction. In previous work we already showed the light extraction improvement of several PhC covered LYSO crystals in computer simulations and practical measurements. In this work, new samples are made using different materials and techniques which allows further efficiency improvements. For rapid prototyping of PhC patterns on scintillators we tested a new method using “Focused Ion Beam (FIB)” patterning. The FIB machine is a device similar to a “Scanning Electron Microscope (SEM)”, but it uses ions (mainly gallium) instead of electrons for the imaging of the samples' surface. The additional feature of FIB devices is the option of surface patterning in nano-scale which was exploited for our samples. Three samples using FIB patterning have been produced. One of them is a direct patterning of the extraction face of a 0.8×0.8×10 $mm^3$ LYS...

  11. Hadronic photon-photon interactions at high energies

    International Nuclear Information System (INIS)

    Engel, R.; Siegen Univ.; Ranft, J.

    1996-01-01

    Photon-photon collisions are investigated in the framework of the two-component Dual Parton Model. The model contains contributions from direct, resolved soft and resolved hard interactions. All free parameters of the model are determined in fits to hadron-hadron and photon-hadron cross section data. The model is shown to agree well to hadron production data from hadron-hadron and photon-hadron collisions. The multiparticle production in hadron-hadron, photon-hadron and photon-photon collisions as predicted by the model is compared. Strong differences are only found as function of the transverse momentum variable. (author)

  12. Validity of a smartphone protractor to measure sagittal parameters in adult spinal deformity.

    Science.gov (United States)

    Kunkle, William Aaron; Madden, Michael; Potts, Shannon; Fogelson, Jeremy; Hershman, Stuart

    2017-10-01

    Smartphones have become an integral tool in the daily life of health-care professionals (Franko 2011). Their ease of use and wide availability often make smartphones the first tool surgeons use to perform measurements. This technique has been validated for certain orthopedic pathologies (Shaw 2012; Quek 2014; Milanese 2014; Milani 2014), but never to assess sagittal parameters in adult spinal deformity (ASD). This study was designed to assess the validity, reproducibility, precision, and efficiency of using a smartphone protractor application to measure sagittal parameters commonly measured in ASD assessment and surgical planning. This study aimed to (1) determine the validity of smartphone protractor applications, (2) determine the intra- and interobserver reliability of smartphone protractor applications when used to measure sagittal parameters in ASD, (3) determine the efficiency of using a smartphone protractor application to measure sagittal parameters, and (4) elucidate whether a physician's level of experience impacts the reliability or validity of using a smartphone protractor application to measure sagittal parameters in ASD. An experimental validation study was carried out. Thirty standard 36″ standing lateral radiographs were examined. Three separate measurements were performed using a marker and protractor; then at a separate time point, three separate measurements were performed using a smartphone protractor application for all 30 radiographs. The first 10 radiographs were then re-measured two more times, for a total of three measurements from both the smartphone protractor and marker and protractor. The parameters included lumbar lordosis, pelvic incidence, and pelvic tilt. Three raters performed all measurements-a junior level orthopedic resident, a senior level orthopedic resident, and a fellowship-trained spinal deformity surgeon. All data, including the time to perform the measurements, were recorded, and statistical analysis was performed to

  13. Photon detector for MEGA

    International Nuclear Information System (INIS)

    Gagliardi, C.A.; Tribble, R.E.

    1991-01-01

    During the past year, we have continued work on the photon detector for the MEGA experiment at Los Alamos, a search for the rare decay μ → eγ to a sensitivity of a few parts in 10 13 . The MEGA photon detector is designed to observe the 52.38 MeV photon produced in a μ → eγ decay with an energy resolution of 1.25 MeV, a position resolution of 2 x 5 mm 2 , a directional resolution of 10 degrees, a time resolution of 500 ps, and an efficiency of 7%. It will consists of four independent concentric cylindrical pair spectrometers mounted within a 1.5 T magnetic field produced by a superconducting solenoid magnet. Each pair spectrometer includes two thin Pb foils to convert photons into e + e - pairs, and thereby, determine both their locations and their vector momenta. The inner drift chamber layer includes a delay line cathode to determine the z coordinates needed for track reconstruction. An MWPC located between two Pb layers identifies the conversion layer so that energy loss corrections may be applied, while plastic scintillators provide timing information. Our, group together with a group from the University of Houston, is responsible for the design and construction of the photon detector, as well as developing the computer codes necessary for Monte Carlo simulations and data analysis. During the past year, our efforts have focused primarily on two tasks, delay line cathode read-out and software development. This report describes our recent work on delay lines and data analysis along with a discussion of the new plans for multiplexing in the photon arm

  14. Early Outcomes of Minimally Invasive Anterior Longitudinal Ligament Release for Correction of Sagittal Imbalance in Patients with Adult Spinal Deformity

    Directory of Open Access Journals (Sweden)

    Armen R. Deukmedjian

    2012-01-01

    Full Text Available The object of this study was to evaluate a novel surgical technique in the treatment of adult degenerative scoliosis and present our early experience with the minimally invasive lateral approach for anterior longitudinal ligament release to provide lumbar lordosis and examine its impact on sagittal balance. Methods. All patients with adult spinal deformity (ASD treated with the minimally invasive lateral retroperitoneal transpsoas interbody fusion (MIS LIF for release of the anterior longitudinal ligament were examined. Patient demographics, clinical data, spinopelvic parameters, and outcome measures were recorded. Results. Seven patients underwent release of the anterior longitudinal ligament (ALR to improve sagittal imbalance. All cases were split into anterior and posterior stages, with mean estimated blood loss of 125 cc and 530 cc, respectively. Average hospital stay was 8.3 days, and mean follow-up time was 9.1 months. Comparing pre- and postoperative 36′′ standing X-rays, the authors discovered a mean increase in global lumbar lordosis of 24 degrees, increase in segmental lumbar lordosis of 17 degrees per level of ALL released, decrease in pelvic tilt of 7 degrees, and decrease in sagittal vertical axis of 4.9 cm. At the last followup, there was a mean improvement in VAS and ODI scores of 26.2% and 18.3%. Conclusions. In the authors’ early experience, release of the anterior longitudinal ligament using the minimally invasive lateral retroperitoneal transpsoas approach may be a feasible alternative in correcting sagittal deformity.

  15. Photon-photon collisions

    International Nuclear Information System (INIS)

    Field, J.H.

    1984-01-01

    The current status, both theoretical and experimental, of two photon collision physics is reviewed with special emphasis on recent experimental results from e + e - storage rings. After a complete presentation of the helicity amplitude formalism for the general process e + e - → Xe + e - , various approximations (transverse photon, Weisaecker Williams) are discussed. Beam polarisation effects and radiative corrections are also briefly considered. A number of specific processes, for which experimental results are now available, are then described. In each case existing theoretical prediction are confronted with experimental results. The processes described include single resonance production, lepton and hadron pair production, the structure functions of the photon, the production of high Psub(T) jets and the total photon photon cross section. In the last part of the review the current status of the subject is summarised and some comments are made on future prospects. These include both extrapolations of current research to higher energy machines (LEP, HERA) as well as a brief mention of both the technical realisation and the physics interest of the real γγ and eγ collisions which may be possible using linear electron colliders in the 1 TeV energy range

  16. Photon-photon collisions

    Energy Technology Data Exchange (ETDEWEB)

    Brodsky, S.J.

    1985-01-01

    The study of photon-photon collisions has progressed enormously, stimulated by new data and new calculational tools for QCD. In the future we can expect precise determinations of ..cap alpha../sub s/ and ..lambda../sup ms/ from the ..gamma..*..gamma.. ..-->.. ..pi../sup 0/ form factor and the photon structure function, as well as detailed checks of QCD, determination of the shape of the hadron distribution amplitudes from ..gamma gamma.. ..-->.. H anti H, reconstruction of sigma/sub ..gamma gamma../ from exclusive channels at low W/sub ..gamma gamma../, definitive studies of high p/sub T/ hadron and jet production, and studies of threshold production of charmed systems. Photon-photon collisions, along with radiative decays of the psi and UPSILON, are ideal for the study of multiquark and gluonic resonances. We have emphasized the potential for resonance formation near threshold in virtually every hadronic exclusive channel, including heavy quark states c anti c c anti c, c anti c u anti u, etc. At higher energies SLC, LEP, ...) parity-violating electroweak effects and Higgs production due to equivalent Z/sup 0/ and W/sup + -/ beams from e ..-->.. eZ/sup 0/ and e ..-->.. nu W will become important. 44 references.

  17. Photon-photon collisions

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1985-01-01

    The study of photon-photon collisions has progressed enormously, stimulated by new data and new calculational tools for QCD. In the future we can expect precise determinations of α/sub s/ and Λ/sup ms/ from the γ*γ → π 0 form factor and the photon structure function, as well as detailed checks of QCD, determination of the shape of the hadron distribution amplitudes from γγ → H anti H, reconstruction of sigma/sub γγ/ from exclusive channels at low W/sub γγ/, definitive studies of high p/sub T/ hadron and jet production, and studies of threshold production of charmed systems. Photon-photon collisions, along with radiative decays of the psi and UPSILON, are ideal for the study of multiquark and gluonic resonances. We have emphasized the potential for resonance formation near threshold in virtually every hadronic exclusive channel, including heavy quark states c anti c c anti c, c anti c u anti u, etc. At higher energies SLC, LEP, ...) parity-violating electroweak effects and Higgs production due to equivalent Z 0 and W +- beams from e → eZ 0 and e → nu W will become important. 44 references

  18. MULTI-PHOTON PHOSPHOR FEASIBILITY RESEARCH

    Energy Technology Data Exchange (ETDEWEB)

    R. Graham; W. Chow

    2003-05-01

    Development of multi-photon phosphor materials for discharge lamps represents a goal that would achieve up to a doubling of discharge (fluorescent) lamp efficacy. This report reviews the existing literature on multi-photon phosphors, identifies obstacles in developing such phosphors, and recommends directions for future research to address these obstacles. To critically examine issues involved in developing a multi-photon phosphor, the project brought together a team of experts from universities, national laboratories, and an industrial lamp manufacturer. Results and findings are organized into three categories: (1) Multi-Photon Systems and Processes, (2) Chemistry and Materials Issues, and (3) Concepts and Models. Multi-Photon Systems and Processes: This category focuses on how to use our current understanding of multi-photon phosphor systems to design new phosphor systems for application in fluorescent lamps. The quickest way to develop multi-photon lamp phosphors lies in finding sensitizer ions for Gd{sup 3+} and identifying activator ions to red shift the blue emission from Pr{sup 3+} due to the {sup 1}S{sub 0} {yields} {sup 1}I{sub 6} transition associated with the first cascading step. Success in either of these developments would lead to more efficient fluorescent lamps. Chemistry and Materials Issues: The most promising multi-photon phosphors are found in fluoride hosts. However, stability of fluorides in environments typically found in fluorescent lamps needs to be greatly improved. Experimental investigation of fluorides in actual lamp environments needs to be undertaken while working on oxide and oxyfluoride alternative systems for backup. Concepts and Models: Successful design of a multi-photon phosphor system based on cascading transitions of Gd{sup 3+} and Pr{sup 3+} depends critically on how the former can be sensitized and the latter can sensitize an activator ion. Methods to predict energy level diagrams and Judd-Ofelt parameters of multi-photon

  19. Photon correlation in single-photon frequency upconversion.

    Science.gov (United States)

    Gu, Xiaorong; Huang, Kun; Pan, Haifeng; Wu, E; Zeng, Heping

    2012-01-30

    We experimentally investigated the intensity cross-correlation between the upconverted photons and the unconverted photons in the single-photon frequency upconversion process with multi-longitudinal mode pump and signal sources. In theoretical analysis, with this multi-longitudinal mode of both signal and pump sources system, the properties of the signal photons could also be maintained as in the single-mode frequency upconversion system. Experimentally, based on the conversion efficiency of 80.5%, the joint probability of simultaneously detecting at upconverted and unconverted photons showed an anti-correlation as a function of conversion efficiency which indicated the upconverted photons were one-to-one from the signal photons. While due to the coherent state of the signal photons, the intensity cross-correlation function g(2)(0) was shown to be equal to unity at any conversion efficiency, agreeing with the theoretical prediction. This study will benefit the high-speed wavelength-tunable quantum state translation or photonic quantum interface together with the mature frequency tuning or longitudinal mode selection techniques.

  20. How is sagittal balance acquired during bipedal gait acquisition? Comparison of neonatal and adult pelves in three dimensions. Evolutionary implications.

    Science.gov (United States)

    Tardieu, Christine; Bonneau, Noémie; Hecquet, Jérôme; Boulay, Christophe; Marty, Catherine; Legaye, Jean; Duval-Beaupère, Geneviève

    2013-08-01

    We compare adult and intact neonatal pelves, using a pelvic sagittal variable, the angle of sacral incidence, which presents significant correlations with vertebral curvature in adults and plays an important role in sagittal balance of the trunk on the lower limbs. Since the lumbar curvature develops in the child in association with gait acquisition, we expect a change in this angle during growth which could contribute to the acquisition of sagittal balance. To understand the mechanisms underlying the sagittal balance in the evolution of human bipedalism, we also measure the angle of incidence of hominid fossils. Fourty-seven landmarks were digitized on 50 adult and 19 intact neonatal pelves. We used a three-dimensional model of the pelvis (DE-VISU program) which calculates the angle of sacral incidence and related functional variables. Cross-sectional data from newborns and adults show that the angle of sacral incidence increases and becomes negatively correlated with the sacro-acetabular distance. During ontogeny the sacrum becomes curved, tends to sink down between the iliac blades as a wedge and moves backward in the sagittal plane relative to the acetabula, thus contributing to the backwards displacement of the center of gravity of the trunk. A chain of correlations links the degree of the sacral slope and of the angle of incidence, which is tightly linked with the lumbar lordosis. We sketch a model showing the coordinated changes occurring in the pelvis and vertebral column during the acquisition of bipedalism in infancy. In the australopithecine pelves, Sts 14 and AL 288-1, and in the Homo erectus Gona pelvis the angle of sacral incidence reaches the mean values of humans. Discussing the incomplete pelves of Ardipithecus ramidus, Australopithecus sediba and the Nariokotome Boy, we suggest how the functional linkage between pelvis and spine, observed in humans, could have emerged during hominid evolution. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. [Application of temporomandibular joint dics reduction in the operation of condylar sagittal fracture].

    Science.gov (United States)

    Wenli, Zeng; Wuchao, Zhou; Jingkun, Zhang; Yisen, Shao; Weihong, Xi

    2017-10-01

    To explore the selection of temporomandibular joint (TMJ) disc reduction and fixation methods in condylar sagittal fracture surgery. A total of 36 patients with condylar fractures were chosen. The follow-up period was more 6 months. All 36 cases of condylar sagittal fracture were fixed with long screw. In the operation, the displaced joint disc was repositioned and fixed. The fixed method included direct suture (22 cases) and anchorage (14 cases). Clinical followups were performed before surgery and 1 month, 3 months, 6 months and 1 year after surgery. Clinicians recorded data related to the Fricton craniomandibular index (CMI) and evaluated the postoperative joint function during followup before surgery and 6 months after surgery. In both groups, function of TMJ significantly improved after surgery. The CMI decreased from 0.213±0.162 and 0.273±0.154 to 0.059±0.072 and 0.064±0.068 (P0.05) before or after surgery. Both methods could effectively improve the dysfunction of the TMJ caused by trauma. The selection of joint disc reduction and fixation methods is based on the displacement and damage degree of the joint disc.

  2. The role of hyperthyroidism as the predisposing factor for superior sagittal sinus thrombosis.

    Science.gov (United States)

    Hwang, Jong-Uk; Kwon, Ki-Young; Hur, Jin-Woo; Lee, Jong-Won; Lee, Hyun-Koo

    2012-09-01

    Superior sagittal sinus thrombosis (SSST) is an uncommon cause of stroke, whose symptoms and clinical course are highly variable. It is frequently associated with a variety of hypercoagulable states. Coagulation abnormalities are commonly seen in patients with hyperthyroidism. To the best of our knowledge, there are few reports on the association between hyperthyroidism and cerebral venous thrombosis. We report on a 31-year-old male patient with a six-year history of hyperthyroidism who developed seizure and mental deterioration. Findings on brain computed tomography (CT) showed multiple hemorrhages in the subcortical area of both middle frontal gyrus and cerebral digital subtraction angiography (DSA) showed irregular intra-luminal filling defects of the superior sagittal sinus. These findings were consistent with hemorrhagic transformation of SSST. Findings on clinical laboratory tests were consistent with hyperthyroidism. In addition, our patient also showed high activity of factors IX and XI. The patient received treatment with oral anticoagulant and prophylthiouracil. His symptoms showed complete improvement. A follow-up cerebral angiography four weeks after treatment showed a recanalization of the SSS. In conclusion, findings of our case indicate that hypercoagulability may contribute to development of SSST in a patient with hyperthyroidism.

  3. Charm production in two-photon collisions

    International Nuclear Information System (INIS)

    Linde, F.L.

    1988-01-01

    The analysis focuses on the production of charmonium resonances η c , χ 0 and χ 2 in two-photon interactions. The measurement of the inclusive production of charged D* mesons is described. 97 refs.; 54 figs.; 15 tabs

  4. Sagittal spinal balance after lumbar spinal fusion: the impact of anterior column support results from a randomized clinical trial with an eight- to thirteen-year radiographic follow-up.

    Science.gov (United States)

    Videbaek, Tina S; Bünger, Cody E; Henriksen, Mads; Neils, Egund; Christensen, Finn B

    2011-02-01

    Randomized clinical trial. To analyze the long-term clinical impact of anterior column support on sagittal balance after lumbar spinal fusion. Several investigators have stressed the importance of maintaining sagittal balance in relation to spinal fusion to avoid lumbar 'flat back,' accelerated adjacent segment degeneration, pain, and inferior functional outcome. Only limited evidence exists on how sagittal alignment affects clinical outcome. Anterior lumbar interbody fusion combined with posterolateral fusion has been proved superior to posterolateral fusion alone regarding outcome and cost-effectiveness. No randomized controlled trial has been published analyzing the effect of anterior support on radiographic measurements of sagittal balance. Between 1996 and 1999, 148 patients with severe chronic low back pain were randomly selected for posterolateral lumbar fusion plus anterior support (PLF + ALIF) or posterolateral lumbar fusion. A total of 92 patients participated. Sagittal balance parameters were examined on full lateral radiographs of the spine: pelvic incidence (PI), pelvic tilt (PT), sacral slope, thoracic kyphosis, lumbar lordosis, and positioning of C7 plumb line. The type of lumbar lordosis was evaluated and outcome assessed by Oswestry Disability Index (ODI). Follow-up rate was 74%. Sagittal balance parameters were similar between randomization groups. None of the parameters differed significantly between patients with an ODI from 0 to 40 and patients with ODI over 40. Balanced patients had a significantly superior outcome as measured by ODI (P Lumbar lordosis and type of lordosis correlated with outcome but could not explain the superior outcome in the group with anterior support. Whether sagittal balance and anterior support during fusion provide a protective effect on adjacent motion segments remains unclear.

  5. Sagittal alignment of the cervical spine in adolescent idiopathic scoliosis treated by posteromedial translation.

    Science.gov (United States)

    Ilharreborde, Brice; Vidal, Christophe; Skalli, Wafa; Mazda, Keyvan

    2013-02-01

    To analyze postoperative changes in the cervical sagittal alignment (CSA) of patients with AIS treated by posteromedial translation. 49 patients with thoracic AIS underwent posterior arthrodesis with hybrid constructs, combining lumbar pedicle screws and thoracic universal clamps. Posteromedial translation was the main correction technique used. 3D radiological parameters were measured from low-dose biplanar radiographs. CSA was assessed using the C2C6 angle, and the central hip vertical axis (CHVA) was used as a reference axis to evaluate patients' balance. Preoperatively, 58 % of patients had thoracic hypokyphosis, and 79 % had a kyphotic CSA. Significant correlation was found (r = 0.45, P = 0.01) between thoracic hypokyphosis and cervical kyphosis. Increase in T4-T12 thoracic kyphosis (average 14.5° ± 10°) was associated with significant decrease in cervical kyphosis in the early postoperative period. The CSA further improved spontaneously during follow-up by 7.6° (P < 0.0001). Significant positive correlation (r = 0.32, P = 0.03) was found between thoracic and cervical improvements. At latest follow-up, 94 % of the patients were normokyphotic and 67 % had a CSA in the physiological range. Sagittal balance of the thoracolumbar spine was not significantly modified postoperatively. However, the procedure significantly changed the position of C2 in regard to the CHVA (C2-CHVA), which reflects headposition (P = 0.012). At last follow-up, the patients sagittal imbalance was not significantly different from the preoperative imbalance (P = 0.34). Thoracic hypokyphosis and cervical hypolordosis, observed in AIS, can be improved postoperatively, when the posteromedial translation technique is used for correction. The cervical spine remains adaptable in most patients, but the proportion of patients with physiological cervical lordosis at final follow-up remained low (24.5 %).

  6. Single-photon sources for quantum technologies - Results of the joint research project SIQUTE

    DEFF Research Database (Denmark)

    Kück, S.; López, M.; Rodiek, B.

    2017-01-01

    In this presentation, the results of the joint research project “Single-Photon Sources for Quantum Technologies” (SIQUTE) [1] will be presented. The focus will be on the development of absolutely characterized single-photon sources, on the realization of an efficient waveguide-based single-photon......-photon source at the telecom wavelengths of 1.3 µm and 1.55 µm, on the implementation of the quantum-enhanced resolution in confocal fluorescence microscopy and on the development of a detector for very low photon fluxes...

  7. Real-time Global Illumination by Simulating Photon Mapping

    DEFF Research Database (Denmark)

    Larsen, Bent Dalgaard

    2004-01-01

    This thesis introduces a new method for simulating photon mapping in realtime. The method uses a variety of both CPU and GPU based algorithms for speeding up the different elements in global illumination. The idea behind the method is to calculate each illumination element individually in a progr......This thesis introduces a new method for simulating photon mapping in realtime. The method uses a variety of both CPU and GPU based algorithms for speeding up the different elements in global illumination. The idea behind the method is to calculate each illumination element individually...... in a progressive and efficient manner. This has been done by analyzing the photon mapping method and by selecting efficient methods, either CPU based or GPU based, which replaces the original photon mapping algorithms. We have chosen to focus on the indirect illumination and the caustics. In our method we first...... divide the photon map into several photon maps in order to make local updates possible. Then indirect illumination is added using light maps that are selectively updated by using selective photon tracing on the CPU. The final gathering step is calculated by using fragment programs and GPU based...

  8. Three-dimensional light distribution near the focus of a tightly focused beam of few-cycle optical pulses

    International Nuclear Information System (INIS)

    Romallosa, Kristine Marie; Bantang, Johnrob; Saloma, Caesar

    2003-01-01

    Via the Richards-Wolf vector diffraction theory, we analyze the three-dimensional intensity distribution of the focal volume that is produced by a strongly focused 750-nm beam of ultrafast, Gaussian-shaped optical pulses (10 -9 s≥ pulse width τ≥1 fs=10 -15 s). Knowledge of the three-dimensional distribution near focus is essential in determining the diffraction-limited resolution of an optical microscope. The optical spectrum of a short pulse is characterized by side frequencies about the carrier frequency. The effect of spectral broadening on the focused intensity distribution is evaluated via the Linfoot's criteria of fidelity, structural content, and correlation quality and with reference to a 750-nm cw focused beam. Different values are considered for τ and numerical aperture of the focusing lens (0.1≤X NA ≤1.2). At X NA =0.8, rapid deterioration of the focused intensity distribution is observed at τ=1.2 fs. This happens because a 750-nm optical pulse with τ=1.2 fs has an associated coherence length of 359.7 nm which is less than the Nyquist sampling interval of 375 nm that is required to sample 750 nm sinusoid without loss of information. The ill-effects of spectral broadening is weaker in two-photon excitation microscope than in its single-photon counterpart for the same focusing lens and light source

  9. Overcorrection of lumbar lordosis for adult spinal deformity with sagittal imbalance: comparison of radiographic outcomes between overcorrection and undercorrection.

    Science.gov (United States)

    Lee, Jung-Hee; Kim, Ki-Tack; Lee, Sang-Hun; Kang, Kyung-Chung; Oh, Hyun-Seok; Kim, Young-Jun; Jung, Hyuk

    2016-08-01

    To determine the correlation of the difference between postoperative lumbar lordosis (LL) and ideal LL with the sagittal vertical axis (SVA) at the final follow-up in patients with adult spinal deformity (ASD). Fifty-one patients with degenerative lumbar kyphosis (DLK) (mean age 66.5 years) who underwent surgical correction with a minimum 2-year follow-up were evaluated. Based on the difference between postoperative LL and ideal LL using the Korean version of Legaye's formula, we divided the 51 patients into two groups: overcorrection (degree of postoperative LL > ideal LL) and undercorrection (degree of postoperative LL < ideal LL). Our clinical series of patients comprised 24 in the overcorrection and 27 in the undercorrection group. No significant differences were found in preoperative pelvic incidence (PI 52.6° vs. 57.3°), sacral slope (SS 23.3° vs. 18.3°), LL (-6.9° vs. -2.3°), thoracic kyphosis (TK 4.7° vs. 4.9°) and SVA (140 vs. 139 mm) except pelvic tilt (PT 29.4° vs. 39.0°), between the two groups. All the patients in the overcorrection group and 16 in the undercorrection group achieved postoperative optimal sagittal balance based on SVA ≤ 50 mm. In addition, significant differences in PT (10.5° vs. 26.7°), SS (42.1° vs. 30.6°), LL (-64.3° vs. -37.1°), TK (22.6° vs. 15.8°), and SVA (-1 vs. 41 mm) between the two groups were observed postoperatively. Furthermore, four patients (16.7 %) in the overcorrection group and eight (50 %) in the undercorrection group had sagittal decompensation at the final follow-up. Our results showed that the difference between postoperative LL and ideal LL had a significant correlation with postoperative and final follow-up SVA in our clinical series. Overcorrection of LL is an effective treatment modality to maintain optimal sagittal alignment in patients with DLK; this suggests that it should be considered in preoperative planning for patients with ASD with sagittal imbalance.

  10. Visibility of mandibular canal on panoramic radiograph after bilateral sagittal split osteotomy (BSSO).

    OpenAIRE

    Politis, Constantinus; Ramirez, Xiomara Botero; Sun, Yi; Lambrichts, Ivo; Heath, Neil; Agbaje, Jimoh Olubanwo

    2013-01-01

    PURPOSE: This study aimed to assess the visibility of the mandibular canal (MC) on panoramic radiographs after bilateral sagittal split osteotomy (BSSO), and to investigate what factors affect this MC visibility. METHODS: We assessed MC visibility on panoramic radiographs of 200 BSSO patients. Images were acquired preoperatively (T0), immediately postoperatively (T1), 6 months postoperatively (T2), and 1 year postoperatively (T3), from three diffe...

  11. Factors influencing spinal sagittal balance, bone mineral density, and Oswestry Disability Index outcome measures in patients with rheumatoid arthritis.

    Science.gov (United States)

    Masamoto, Kazutaka; Otsuki, Bungo; Fujibayashi, Shunsuke; Shima, Koichiro; Ito, Hiromu; Furu, Moritoshi; Hashimoto, Motomu; Tanaka, Masao; Lyman, Stephen; Yoshitomi, Hiroyuki; Tanida, Shimei; Mimori, Tsuneyo; Matsuda, Shuichi

    2018-02-01

    To identify the factors influencing spinal sagittal alignment, bone mineral density (BMD), and Oswestry Disability Index (ODI) outcome measures in patients with rheumatoid arthritis (RA). We enrolled 272 RA patients to identify the factors influencing sagittal vertical axis (SVA). Out of this, 220 had evaluation of bone mineral density (BMD) and vertebral deformity (VD) on the sagittal plane; 183 completed the ODI questionnaire. We collected data regarding RA-associated clinical parameters and standing lateral X-ray images via an ODI questionnaire from April to December 2012 at a single center. Patients with a history of spinal surgery or any missing clinical data were excluded. Clinical parameters included age, sex, body mass index, RA disease duration, disease activity score 28 erythrocyte sedimentation rate (DAS28-ESR), serum anti-cyclic citrullinated peptide antibody, serum rheumatoid factor, serum matrix metalloproteinase-3, BMD and treatment type at survey, such as methotrexate (MTX), biological disease-modifying anti-rheumatic drugs, and glucocorticoids. We measured radiological parameters including pelvic incidence (PI), lumbar lordosis (LL), and SVA. We statistically identified the factors influencing SVA, BMD, VD, and ODI using multivariate regression analysis. Multivariate regression analysis showed that larger SVA correlated with older age, higher DAS28-ESR, MTX nonuse, and glucocorticoid use. Lower BMD was associated with female, older age, higher DAS28-ESR, and MTX nonuse. VD was associated with older age, longer disease duration, lower BMD, and glucocorticoid use. Worse ODI correlated with older age, larger PI-LL mismatch or larger SVA, higher DAS28-ESR, and glucocorticoid use. In managing low back pain and spinal sagittal alignment in RA patients, RA-related clinical factors and the treatment type should be taken into consideration.

  12. Cost of treating sagittal synostosis in the first year of life.

    Science.gov (United States)

    Abbott, Megan M; Rogers, Gary F; Proctor, Mark R; Busa, Kathleen; Meara, John G

    2012-01-01

    Endoscopically assisted suturectomy (EAS) has been reported to reduce the morbidity and cost of treating sagittal synostosis when compared with traditional open cranial vault remodeling (CVR) procedures. Whereas the former claim is well substantiated and intuitive, the latter has not been validated by rigorous cost analysis. Patient medical records and financial database reports were culled retrospectively to determine the total cost associated with both EAS and CVR during 1 year of care. Recorded cost data included physician and hospital services, orthotic equipment and fittings, and indirect patient cost. Ten patients treated with CVR were compared with 10 patients who underwent EAS. The CVR patients incurred greater costs in nearly all categories studied, including overall 1-year costs, physician services, hospital services, supplies/equipment, medications/intravenous fluids, and laboratory and blood bank services. Postoperative costs were greater in the EAS group, primarily because of the cost associated with orthotic services and indirect patient costs for travel and lost work. However, overall indirect patient costs for the whole year did not differ between the groups. One-year median costs were $55,121 for CVR and $23,377 for EAS. Early clinical results were similar for the 2 groups. Cranial vault remodeling was more costly in the first year of treatment than EAS, although indirect patient costs were similar. The favorable cost of EAS compared with CVR provides further justification to consider this procedure as first-line treatment of sagittal synostosis in young infants.

  13. The effects of the sagittal plane malpositioning of the patella and concomitant quadriceps hypotrophy on the patellofemoral joint: a finite element analysis.

    Science.gov (United States)

    Aksahin, Ertugrul; Kocadal, Onur; Aktekin, Cem N; Kaya, Defne; Pepe, Murad; Yılmaz, Serdar; Yuksel, H Yalcin; Bicimoglu, Ali

    2016-03-01

    Anterior knee pain is a common symptom after intramedullary nailing in tibia shaft fracture. Moreover, patellofemoral malalignment is also known to be a major reason for anterior knee pain. Patellofemoral malalignment predisposes to increased loading in patellar cartilage. In the previous study, we have demonstrated the quadriceps atrophy and patellofemoral malalignment after intramedullary nailing due to tibia shaft fracture. In this study, our aim was to clarify the effects of quadriceps atrophy and patellofemoral malalignment with the pathologic loading on the joint cartilage. Mesh models of patellofemoral joint were constructed with CT images and integrated with soft tissue components such as menisci and ligaments. Physiological and sagittal tilt models during extension and flexion at 15°, 30° and 60° were created generating eight models. All the models were applied with 137 N force to present the effects of normal loading and 115.7 N force for the simulation of quadriceps atrophy. Different degrees of loading were applied to evaluate the joint contact area and pressure value with the finite element analysis. There was increased patellofemoral contact area in patellar tilt models with respect to normal models. The similar loading patterns were diagnosed in all models at 0° and 15° knee flexion when 137 N force was applied. Higher loading values were obtained at 30° and 60° knee flexions in sagittal tilt models. Furthermore, in the sagittal tilt models, in which the quadriceps atrophy was simulated, the loadings at 30° and 60° knee flexion were higher than in the physiological ones. Sagittal malalignment of the patellofemoral joint is a new concept that results in different loading patterns in the patellofemoral joint biomechanics. This malalignment in sagittal plane leads to increased loading values on the patellofemoral joint at 30° and 60° of the knee flexions. This new concept should be kept in mind during the course of diagnosis and treatment

  14. The sagittal stem alignment and the stem version clearly influence the impingement-free range of motion in total hip arthroplasty: a computer model-based analysis.

    Science.gov (United States)

    Müller, Michael; Duda, Georg; Perka, Carsten; Tohtz, Stephan

    2016-03-01

    The component alignment in total hip arthroplasty influences the impingement-free range of motion (ROM). While substantiated data is available for the cup positioning, little is known about the stem alignment. Especially stem rotation and the sagittal alignment influence the position of the cone in relation to the edge of the socket and thus the impingement-free functioning. Hence, the question arises as to what influence do these parameters have on the impingement-free ROM? With the help of a computer model the influence of the sagittal stem alignment and rotation on the impingement-free ROM were investigated. The computer model was based on the CT dataset of a patient with a non-cemented THA. In the model the stem version was set at 10°/0°/-10° and the sagittal alignment at 5°/0°/-5°, which resulted in nine alternative stem positions. For each position, the maximum impingement-free ROM was investigated. Both stem version and sagittal stem alignment have a relevant influence on the impingement-free ROM. In particular, flexion and extension as well as internal and external rotation capability present evident differences. In the position intervals of 10° sagittal stem alignment and 20° stem version a difference was found of about 80° in the flexion and 50° in the extension capability. Likewise, differences were evidenced of up to 72° in the internal and up to 36° in the external rotation. The sagittal stem alignment and the stem torsion have a relevant influence on the impingement-free ROM. To clarify the causes of an impingement or accompanying problems, both parameters should be examined and, if possible, a combined assessment of these factors should be made.

  15. Bone-femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty.

    Science.gov (United States)

    Kuriyama, Shinichi; Hyakuna, Katsufumi; Inoue, Satoshi; Kawai, Yasutsugu; Tamaki, Yasuyuki; Ito, Hiromu; Matsuda, Shuichi

    2018-05-01

    This study retrospectively evaluated the fate of mismatch between an uncemented femoral component and each femoral cut surface (i.e., wedge-shaped gap) relative to sagittal mechanical alignment in total knee arthroplasty (TKA). Primary TKA was performed on 99 consecutive knees. The femoral components were aligned to the sagittal mechanical axis with CT-based navigation. All patients were assessed with postoperative true lateral radiographs. Bone-side surfaces of the uncemented femoral component were divided into five zones: anterior flange, anterior chamfer, posterior chamfer, posterior part, and distal part, which were defined as zones 1 to 5, respectively. Bone filling of wedge-shaped gaps in each zone was evaluated after 1 year. Femoral anterior notching did not occur. However, wedge-shaped gaps were observed in at least one zone in 23 of 99 knees (23%), most frequently in zone 5 (18%). There were 9 and 7 gaps in zones 1 and 2, respectively. The femoral component showed malpositioning of approximately 3° of flexion in cases with wedge-shaped gaps in zones 2 and/or 5. After one year, 67% (6/9) of zone 1, 100% (7/7) of zone 2, and 94% (17/18) of zone 5 wedge-shaped gaps were filled in with new bone. Femoral alignment relative to sagittal mechanical axis caused wedge-shaped gaps due to unstable anterior bone cutting through hard bone, but the small gaps were not clinically significant and filled in within one year. Sagittal setting of the femoral component should aim for the anatomical axis rather than the mechanical axis. IV.

  16. Biomechanical analysis of the effect of occlusal force on osteosynthesis following sagittal split ramus osteotomy

    International Nuclear Information System (INIS)

    Okuda, Katsuya; Nakajima, Masahiro; Kakudo, Kenji

    2009-01-01

    Relapse is sometimes observed during the postoperative course following sagittal split ramus osteotomy which is widely used to correct jaw deformities. Relapse may be caused by biomechanical factors such as the postoperative occlusal force. We evaluated serial changes in the stress distribution associated with postoperative occlusal force and jaw-closing pressure on the mandible and osteosynthesis plate using three-dimensional finite element analysis. Based on CT data, we produced mandibular models 1, 3, 6, and 12 months after sagittal split ramus osteotomy, and subjected them to simulated occlusal force and jaw-closing pressure. Changes in equivalent stress in the proximal and distal segments, at the osteosynthesis site, and the fixation plate were evaluated by three-dimensional finite element analysis. The equivalent stresses in the proximal and distal segments slightly increased over time from 1 to 12 months after the operation. In particular, marked stress concentration was observed at the anterior border of the ramus at each measurement area. Stress at the osteosynthesis site increased from 1 to 6 months after the operation, but decreased after 12 months. As a result of postoperative occlusal forces and jaw-closing pressure, stress was concentrated at the anterior border of the ramus in the proximal segment. Between 3 and 6 months after the operation, tensile stress was concentrated at the upper and lower ends of the osteotomy line at the osteosynthesis site. These biomechanical findings indicate the application of clockwise stress on the distal segment up to 6 months after the operation. We concluded that sagittal split ramus osteotomy runs the risk of relapse between 3 and 6 months after the operation. (author)

  17. Photon-photon and photon-hadron processes in relativistic heavy ion collisions

    International Nuclear Information System (INIS)

    Baron, N.C.

    1993-11-01

    Photon-photon and photon-hadron interactions in relativistic heavy ion collisions are studied in the framework of the impact parameter dependent equivalent photon approximation. Improvements of this method, like formfactor inclusion and geometrical modifications are developed. In disruptive relativistic heavy ion collisions where the heavy ions overlapp during the collision, electromagnetic processes are an important background to other mechanisms. In peripheral (non-disruptive) relativistic heavy ion collisions where the ions pass each other without strong interactions, the electromagnetic processes can be studied in their pure form. The lepton pair production is an important diagnostic tool in relativistic heavy ion collisions. The coherent γγ lepton pair production is therefore extensively studied in disruptive but also in non-disruptive collisions. The effects of strong interactions on the coherent γγ lepton pair production in disruptive collisions are discussed in terms of a simple stopping model. Coherent γγ dielectron production contributes to the dilepton production in high energy hadron-hadron collisions. As an example, the coherent dielectron production in π - p collisions is studied in terms of the equivalent photon approximation. Peripheral ultrarelativistic heavy ion collisions open up new possibilities for γγ physics. Taking into account γA background reactions, typical γγ processes in the relevant invariant mass ranges are discussed. The extreme high energy part of the equivalent photon spectrum leads to hard photon-parton reactions. As a potential tool to investigate the gluon distribution function of nucleons, thee q anti q production via the γg fusion in ultrarelativistic heavy ion collisions is studied. It is the purpose of this work to investigate how photon-photon and photon-hadron reactions in relativistic heavy ion collisions may contribute to the understanding of QCD and the standard model. (orig.) [de

  18. The development of efficient two-photon singlet oxygen sensitizers

    DEFF Research Database (Denmark)

    Nielsen, Christian Benedikt

    The development of efficient two-photon singlet oxygen sensitizers is addressed focusing on organic synthesis. Photophysical measurements were carried out on new lipophilic molecules, where two-photon absorption cross sections and singlet oxygen quantumyields were measured. Design principles...... for making efficient two-photon singlet oxygen sensitizers were then constructed from these results. Charge-transfer in the excited state of the prepared molecules was shown to play a pivotal role in the generationof singlet oxygen. This was established through studies of substituent effects on both...... the singlet oxygen yield and the two-photon absorption cross section, where it was revealed that a careful balancing of the amount of charge transfer present in theexcited state of the sensitizer is necessary to obtain both a high singlet oxygen quantum yield and a high two-photon cross section. An increasing...

  19. Demultiplexing of photonic temporal modes by a linear system

    Science.gov (United States)

    Xu, Shuang; Shen, H. Z.; Yi, X. X.

    2018-03-01

    Temporally and spatially overlapping but field-orthogonal photonic temporal modes (TMs) that intrinsically span a high-dimensional Hilbert space are recently suggested as a promising means of encoding information on photons. Presently, the realization of photonic TM technology, particularly to retrieve the information it carries, i.e., demultiplexing of photonic TMs, is mostly dependent on nonlinear medium and frequency conversion. Meanwhile, its miniaturization, simplification, and optimization remain the focus of research. In this paper, we propose a scheme of TM demultiplexing using linear systems consisting of resonators with linear couplings. Specifically, we examine a unidirectional array of identical resonators with short environment correlations. For both situations with and without tunable couplers, propagation formulas are derived to demonstrate photonic TM demultiplexing capabilities. The proposed scheme, being entirely feasible with current technologies, might find potential applications in quantum information processing.

  20. The lumbar lordosis index: a new ratio to detect spinal malalignment with a therapeutic impact for sagittal balance correction decisions in adult scoliosis surgery.

    Science.gov (United States)

    Boissière, Louis; Bourghli, Anouar; Vital, Jean-Marc; Gille, Olivier; Obeid, Ibrahim

    2013-06-01

    Sagittal malalignment is frequently observed in adult scoliosis. C7 plumb line, lumbar lordosis and pelvic tilt are the main factors to evaluate sagittal balance and the need of a vertebral osteotomy to correct it. We described a ratio: the lumbar lordosis index (ratio lumbar lordosis/pelvic incidence) (LLI) and analyzed its relationships with spinal malalignment and vertebral osteotomies. 53 consecutive patients with a surgical adult scoliosis had preoperative and postoperative full spine EOS radiographies to measure spino-pelvic parameters and LLI. The lack of lordosis was calculated after prediction of theoretical lumbar lordosis. Correlation analysis between the different parameters was performed. All parameters were correlated with spinal malalignment but LLI is the most correlated parameter (r = -0.978). It is also the best parameter in this study to predict the need of a spinal osteotomy (r = 1 if LLI <0.5). LLI is a statistically validated parameter for sagittal malalignment analysis. It can be used as a mathematical tool to detect spinal malalignment in adult scoliosis and guides the surgeon decision of realizing a vertebral osteotomy for adult scoliosis sagittal correction. It can be used as well for the interpretation of clinical series in adult scoliosis.

  1. The stability of mandibular prognathism corrected by bilateral sagittal split osteotomies: a comparison of bi-cortical osteosynthesis and mono-cortical osteosynthesis.

    Science.gov (United States)

    Hsu, S S-P; Huang, C-S; Chen, P K-T; Ko, E W-C; Chen, Y-R

    2012-02-01

    This study evaluated the differences in surgical changes and post-surgical changes between bi-cortical and mono-cortical osteosynthesis (MCO) in the correction of skeletal Class III malocclusion with bilateral sagittal split osteotomies (BSSOs). Twenty-five patients had bi-cortical osteosynthesis (BCO), 32 patients had mono-cortical fixation. Lateral and postero-anterior cephalometric radiographs, taken at the time of surgery, before surgery, 1 month after surgery, and on completion of orthodontic treatment (mean 9.9 months after surgery), were obtained for evaluation. Cephalometric analysis and superimposition were used to investigate the surgical and post-surgical changes. Independent t-test was performed to compare the difference between the two groups. Pearson's correlations were tested to evaluate the factors related to the relapse of the mandible. The sagittal relapse rate was 20% in the bi-cortical and 25% in the mono-cortical group. The forward-upward rotation of the mandible in the post-surgical period contributed most of the sagittal relapse. There were no statistically significant differences in sagittal and vertical changes between the two groups during surgery and in the post-surgical period. No factors were found to correlate with post-surgical relapse, but the intergonial width increased more in the bi-cortical group. The study suggested that both methods of skeletal fixation had similar postoperative stability. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Spino-pelvic sagittal balance of spondylolisthesis: a review and classification.

    Science.gov (United States)

    Labelle, Hubert; Mac-Thiong, Jean-Marc; Roussouly, Pierre

    2011-09-01

    In L5-S1 spondylolisthesis, it has been clearly demonstrated over the past decade that sacro-pelvic morphology is abnormal and that it can be associated to an abnormal sacro-pelvic orientation as well as to a disturbed global sagittal balance of the spine. The purpose of this article is to review the work done within the Spinal Deformity Study Group (SDSG) over the past decade, which has led to a classification incorporating this recent knowledge. The evidence presented has been derived from the analysis of the SDSG database, a multi-center radiological database of patients with L5-S1 spondylolisthesis, collected from 43 spine surgeons in North America and Europe. The classification defines 6 types of spondylolisthesis based on features that can be assessed on sagittal radiographs of the spine and pelvis: (1) grade of slip, (2) pelvic incidence, and (3) spino-pelvic alignment. A reliability study has demonstrated substantial intra- and inter-observer reliability similar to other currently used classifications for spinal deformity. Furthermore, health-related quality of life measures were found to be significantly different between the 6 types, thus supporting the value of a classification based on spino-pelvic alignment. The clinical relevance is that clinicians need to keep in mind when planning treatment that subjects with L5-S1 spondylolisthesis are a heterogeneous group with various adaptations of their posture. In the current controversy on whether high-grade deformities should or should not be reduced, it is suggested that reduction techniques should preferably be used in subjects with evidence of abnormal posture, in order to restore global spino-pelvic balance and improve the biomechanical environment for fusion.

  3. Super-resolving random-Gaussian apodized photon sieve.

    Science.gov (United States)

    Sabatyan, Arash; Roshaninejad, Parisa

    2012-09-10

    A novel apodized photon sieve is presented in which random dense Gaussian distribution is implemented to modulate the pinhole density in each zone. The random distribution in dense Gaussian distribution causes intrazone discontinuities. Also, the dense Gaussian distribution generates a substantial number of pinholes in order to form a large degree of overlap between the holes in a few innermost zones of the photon sieve; thereby, clear zones are formed. The role of the discontinuities on the focusing properties of the photon sieve is examined as well. Analysis shows that secondary maxima have evidently been suppressed, transmission has increased enormously, and the central maxima width is approximately unchanged in comparison to the dense Gaussian distribution. Theoretical results have been completely verified by experiment.

  4. Photonic Crystals Towards Nanoscale Photonic Devices

    CERN Document Server

    Lourtioz, Jean-Michel; Berger, Vincent; Gérard, Jean-Michel; Maystre, Daniel; Tchelnokov, Alexei; Pagnoux, Dominique

    2008-01-01

    Just like the periodical crystalline potential in solid state crystals determines their properties for the conduction of electrons, the periodical structuring of photonic crystals leads to envisioning the possibility of achieving a control of the photon flux in dielectric and metallic materials. The use of photonic crystals as cages for storing, filtering or guiding light at the wavelength scale paves the way to the realization of optical and optoelectronic devices with ultimate properties and dimensions. This will contribute towards meeting the demands for greater miniaturization imposed by the processing of an ever increasing number of data. Photonic Crystals will provide students and researchers from different fields with the theoretical background required for modelling photonic crystals and their optical properties, while at the same time presenting the large variety of devices, ranging from optics to microwaves, where photonic crystals have found application. As such, it aims at building bridges between...

  5. Photonic Crystals Towards Nanoscale Photonic Devices

    CERN Document Server

    Lourtioz, Jean-Michel; Berger, Vincent; Gérard, Jean-Michel; Maystre, Daniel; Tchelnokov, Alexis

    2005-01-01

    Just like the periodical crystalline potential in solid-state crystals determines their properties for the conduction of electrons, the periodical structuring of photonic crystals leads to envisioning the possibility of achieving a control of the photon flux in dielectric and metallic materials. The use of photonic crystals as a cage for storing, filtering or guiding light at the wavelength scale thus paves the way to the realisation of optical and optoelectronic devices with ultimate properties and dimensions. This should contribute toward meeting the demands for a greater miniaturisation that the processing of an ever increasing number of data requires. Photonic Crystals intends at providing students and researchers from different fields with the theoretical background needed for modelling photonic crystals and their optical properties, while at the same time presenting the large variety of devices, from optics to microwaves, where photonic crystals have found applications. As such, it aims at building brid...

  6. Single Photon Avalanche Diodes: Towards the Large Bidimensional Arrays

    Directory of Open Access Journals (Sweden)

    Emilio Sciacca

    2008-08-01

    Full Text Available Single photon detection is one of the most challenging goals of photonics. In recent years, the study of ultra-fast and/or low-intensity phenomena has received renewed attention from the academic and industrial communities. Intense research activity has been focused on bio-imaging applications, bio-luminescence, bio-scattering methods, and, more in general, on several applications requiring high speed operation and high timing resolution. In this paper we present design and characterization of bi-dimensional arrays of a next generation of single photon avalanche diodes (SPADs. Single photon sensitivity, dark noise, afterpulsing and timing resolution of the single SPAD have been examined in several experimental conditions. Moreover, the effects arising from their integration and the readout mode have also been deeply investigated.

  7. Active Photonic crystal fibers for high power applications

    DEFF Research Database (Denmark)

    Olausson, Christina Bjarnal Thulin

    The photonic crystal ber technology provides means to realize bers optimized for high power operation, due to the large single-mode cores and the unique design exibility of the microstructure. The work presented in this thesis focuses on improving the properties of active photonic crystal bers...... contributed to the compounding of new and improved material compositions. The second part is an investigation of pump absorption in photonic crystal bers, demonstrating that the microstructure in photonic crystal bers improves the pump absorption by up to a factor of two compared to step-index bers....... This plays an important role in high power lasers and ampliers with respect to efficiency, packaging, and thermal handling. The third part of the work has involved developing tools for characterizing the mode quality and stability of large core bers. Stable, single-mode bers with larger cores are essential...

  8. Radiographic analysis of the correlation between ossification of the nuchal ligament and sagittal alignment and segmental stability of the cervical spine in patients with cervical spondylotic myelopathy.

    Science.gov (United States)

    Ying, Jinwei; Teng, Honglin; Qian, Yunfan; Hu, Yingying; Wen, Tianyong; Ruan, Dike; Zhu, Minyu

    2018-01-01

    Background Ossification of the nuchal ligament (ONL) caused by chronic injury to the nuchal ligament (NL) is very common in instability-related cervical disorders. Purpose To determine possible correlations between ONL, sagittal alignment, and segmental stability of the cervical spine. Material and Methods Seventy-three patients with cervical spondylotic myelopathy (CSM) and ONL (ONL group) and 118 patients with CSM only (control group) were recruited. Radiographic data included the characteristics of ONL, sagittal alignment and segmental stability, and ossification of the posterior longitudinal ligament (OPLL). We performed comparisons in terms of radiographic parameters between the ONL and control groups. The correlations between ONL size, cervical sagittal alignment, and segmental stability were analyzed. Multivariate logistic regression was used to identify the independent risk factors of the development of ONL. Results C2-C7 sagittal vertical axis (SVA), T1 slope (T1S), T1S minus cervical lordosis (T1S-CL) on the lateral plain, angular displacement (AD), and horizontal displacement (HD) on the dynamic radiograph increased significantly in the ONL group compared with the control group. The size of ONL significantly correlated with C2-C7 SVA, T1S, AD, and HD. The incidence of ONL was higher in patients with OPLL and segmental instability. Cervical instability, sagittal malalignment, and OPLL were independent predictors of the development of ONL through multivariate analysis. Conclusion Patients with ONL are more likely to have abnormal sagittal alignment and instability of the cervical spine. Thus, increased awareness and appreciation of this often-overlooked radiographic finding is warranted during diagnosis and treatment of instability-related cervical pathologies and injuries.

  9. Fresnel Lenses fabricated by femtosecond laser micromachining on Polymer 1D Photonic Crystal

    Directory of Open Access Journals (Sweden)

    Guduru Surya S.K.

    2013-11-01

    Full Text Available We report the fabrication of micro Fresnel lenses by femtosecond laser surface ablation on polymer 1D photonic crystals. This device is designed to focus the transmitted wavelength of the photonic crystal and filter the wavelengths corresponding to the photonic band gap region. Integration of such devices in a wavelength selective light harvesting and filtering microchip can be achieved.

  10. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying Biomedical Photonics, spectroscopy and microscopy This volume discusses biomedical photonics, spectroscopy and microscopy, the basic physical principles underlying the technology and its applications. The topics discussed in this volume are: Biophotonics; Fluorescence and Phosphorescence; Medical Photonics; Microscopy; Nonlinear Optics; Ophthalmic Technology; Optical Tomography; Optofluidics; Photodynamic Therapy; Image Processing; Imaging Systems; Sensors; Single Molecule Detection; Futurology in Photonics. Comprehensive and accessible cov

  11. Scanless two-photon excitation of channelrhodopsin-2

    DEFF Research Database (Denmark)

    Papagiakoumou, E.; Anselmi, F.; Bègue, A.

    2010-01-01

    developed a method that combines generalized phase contrast with temporal focusing (TF-GPC) to shape two-photon excitation for this purpose. The illumination patterns are generated automatically from fluorescence images of neurons and shaped to cover the cell body or dendrites, or distributed groups...... of cells. The TF-GPC two-photon excitation patterns generated large photocurrents in Channelrhodopsin-2–expressing cultured cells and neurons and in mouse acute cortical slices. The amplitudes of the photocurrents can be precisely modulated by controlling the size and shape of the excitation volume and...

  12. Sagittal fractures of the third carpal bone in horses: 12 cases (1977-1985)

    International Nuclear Information System (INIS)

    Fischer, A.T. Jr.; Stover, S.M.

    1987-01-01

    Third carpal sagittal fractures were found to be related to racing injuries in 10 of 12 horses. These fractures occurred most commonly on the medial aspect of the bone. A dorsoproximal-dorsodistal view of the carpus was required to visualize the fracture in all cases. Healing of the fracture required periods of rest of up to one year. Conservative management of these fractures resulted in return to function in 7 of 12 horses

  13. The Role of Hyperthyroidism as the Predisposing Factor for Superior Sagittal Sinus Thrombosis

    OpenAIRE

    Hwang, Jong-Uk; Kwon, Ki-Young; Hur, Jin-Woo; Lee, Jong-Won; Lee, Hyun-Koo

    2012-01-01

    Superior sagittal sinus thrombosis (SSST) is an uncommon cause of stroke, whose symptoms and clinical course are highly variable. It is frequently associated with a variety of hypercoagulable states. Coagulation abnormalities are commonly seen in patients with hyperthyroidism. To the best of our knowledge, there are few reports on the association between hyperthyroidism and cerebral venous thrombosis. We report on a 31-year-old male patient with a six-year history of hyperthyroidism who devel...

  14. Two-photon patterning of a polymer containing Y-shaped azochromophores

    International Nuclear Information System (INIS)

    Ambrosio, A.; Orabona, E.; Maddalena, P.; Camposeo, A.; Polo, M.; Neves, A. A. R.; Pisignano, D.; Carella, A.; Borbone, F.; Roviello, A.

    2009-01-01

    We report on the patterning of the free surface of azo-based polymer films by means of mass migration driven by one- or two-photon absorption. A symmetric donor-acceptor-donor structured Y-shaped azochromophore is specifically synthesized to enhance two-photon absorption in the polymer. The exposure of the polymer film to a focused laser beam results in light-driven mass migration for both one- and two-photon absorptions. Features with subdiffraction resolution (250 nm) are realized and the patterning dynamics is investigated as a function of the light dose. Furthermore, functional photonic structures, such as diffraction gratings with periods ranging between 0.5 and 2.0 μm, have been realized

  15. Sagittal Abdominal Diameter: Application in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Thaís Da Silva-Ferreira

    2014-05-01

    Full Text Available Excess visceral fat is associated with cardiovascular risk factors. Sagittal abdominal diameter (SAD has recently been highlighted as an indicator of abdominal obesity, and also may be useful in predicting cardiovascular risk. The purpose of the present study was to review the scientific literature on the use of SAD in adult nutritional assessment. A search was conducted for scientific articles in the following electronic databases: SciELO , MEDLINE (PubMed and Virtual Health Library. SAD is more associated with abdominal fat (especially visceral, and with different cardiovascular risk factors, such as, insulin resistance, blood pressure, and serum lipoproteins than the traditional methods of estimating adiposity, such as body mass index and waist-to-hip ratio. SAD can also be used in association with other anthropometric measures. There are still no cut-off limits established to classify SAD as yet. SAD can be an alternative measure to estimate visceral adiposity. However, the few studies on this diameter, and the lack of consensus on the anatomical site to measure SAD, are obstacles to establish cut-off limits to classify it.

  16. Tomography of photon-added and photon-subtracted states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    The purpose of this paper is to introduce symplectic and optical tomograms of photon-added and photon-subtracted quantum states. Explicit relations for the tomograms of photon-added and photon-subtracted squeezed coherent states and squeezed number states are obtained. Generating functions for the

  17. Evaluation of Mandibular Anatomy Associated With Bad Splits in Sagittal Split Ramus Osteotomy of Mandible.

    Science.gov (United States)

    Wang, Tongyue; Han, Jeong Joon; Oh, Hee-Kyun; Park, Hong-Ju; Jung, Seunggon; Park, Yeong-Joon; Kook, Min-Suk

    2016-07-01

    This study aimed to identify risk factors associated with bad splits during sagittal split ramus osteotomy by using three-dimensional computed tomography. This study included 8 bad splits and 47 normal patients without bad splits. Mandibular anatomic parameters related to osteotomy line were measured. These included anteroposterior width of the ramus at level of lingula, distance between external oblique ridge and lingula, distance between sigmoid notch and inferior border of mandible, mandibular angle, distance between inferior outer surface of mandibular canal and inferior border of mandible under distal root of second molar (MCEM), buccolingual thickness of the ramus at level of lingula, and buccolingual thickness of the area just distal to first molar (BTM1) and second molar (BTM2). The incidence of bad splits in 625 sagittal split osteotomies was 1.28%. Compared with normal group, bad split group exhibited significantly thinner BTM2 and shorter sigmoid notch and inferior border of mandible (P bad splits. These anatomic data may help surgeons to choose the safest surgical techniques and best osteotomy sites.

  18. Skull fracture with effacement of the superior sagittal sinus following drone impact: a case report.

    Science.gov (United States)

    Chung, Lawrance K; Cheung, Yuri; Lagman, Carlito; Au Yong, Nicholas; McBride, Duncan Q; Yang, Isaac

    2017-09-01

    The popularity of unmanned aerial vehicles, or drones, raises safety concerns as they become increasingly common for commercial, personal, and recreational use. Collisions between drones and people may result in serious injuries. A 13-year-old male presented with a comminuted depressed skull fracture causing effacement of the superior sagittal sinus secondary to a racing drone impact. The patient experienced a brief loss of consciousness and reported lower extremity numbness and weakness after the accident. Imaging studies revealed bone fragments crossing the superior sagittal sinus with a short, focal segment of blood flow interruption. Neurosurgical intervention was deferred given the patient's improving neurological deficits, and the patient was treated conservatively. He was discharged home in stable condition. Drones may represent a hazard when operated inappropriately due to their capacity to fly at high speeds and altitudes. Impacts from drones can carry enough force to cause skull fractures and significant head injuries. The rising popularity of drones likely translates to an increased incidence of drone-related injuries. Thus, clinicians should be aware of this growing trend.

  19. Patients with proximal junctional kyphosis requiring revision surgery have higher postoperative lumbar lordosis and larger sagittal balance corrections.

    Science.gov (United States)

    Kim, Han Jo; Bridwell, Keith H; Lenke, Lawrence G; Park, Moon Soo; Song, Kwang Sup; Piyaskulkaew, Chaiwat; Chuntarapas, Tapanut

    2014-04-20

    Case control study. To evaluate risk factors in patients in 3 groups: those without proximal junctional kyphosis (PJK) (N), with PJK but not requiring revision (P), and then those with PJK requiring revision surgery (S). It is becoming clear that some patients maintain stable PJK angles, whereas others progress and develop severe PJK necessitating revision surgery. A total of 206 patients at a single institution from 2002 to 2007 with adult scoliosis with 2-year minimum follow-up (average 3.5 yr) were analyzed. Inclusion criteria were age more than 18 years and primary fusions greater than 5 levels from any thoracic upper instrumented vertebra to any lower instrumented vertebrae. Revisions were excluded. Radiographical assessment included Cobb measurements in the coronal/sagittal plane and measurements of the PJK angle at postoperative time points: 1 to 2 months, 2 years, and final follow-up. PJK was defined as an angle greater than 10°. The prevalence of PJK was 34%. The average age in N was 49.9 vs. 51.3 years in P and 60.1 years in S. Sex, body mass index, and smoking status were not significantly different between groups. Fusions extending to the pelvis were 74%, 85%, and 91% of the cases in groups N, P, and S. Instrumentation type was significantly different between groups N and S, with a higher number of upper instrumented vertebra hooks in group N. Radiographical parameters demonstrated a higher postoperative lumbar lordosis and a larger sagittal balance change, with surgery in those with PJK requiring revision surgery. Scoliosis Research Society postoperative pain scores were inferior in group N vs. P and S, and Oswestry Disability Index scores were similar between all groups. Patients with PJK requiring revision were older, had higher postoperative lumbar lordosis, and larger sagittal balance corrections than patients without PJK. Based on these data, it seems as though older patients with large corrections in their lumbar lordosis and sagittal balance

  20. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying the technology instrumentation of photonics This volume discusses photonics technology and instrumentation. The topics discussed in this volume are: Communication Networks; Data Buffers; Defense and Security Applications; Detectors; Fiber Optics and Amplifiers; Green Photonics; Instrumentation and Metrology; Interferometers; Light-Harvesting Materials; Logic Devices; Optical Communications; Remote Sensing; Solar Energy; Solid-State Lighting; Wavelength Conversion Comprehensive and accessible coverage of the whole of modern photonics Emphas

  1. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    Discusses the basic physical principles underlying thescience and technology of nanophotonics, its materials andstructures This volume presents nanophotonic structures and Materials.Nanophotonics is photonic science and technology that utilizeslight/matter interactions on the nanoscale where researchers arediscovering new phenomena and developing techniques that go wellbeyond what is possible with conventional photonics andelectronics.The topics discussed in this volume are: CavityPhotonics; Cold Atoms and Bose-Einstein Condensates; Displays;E-paper; Graphene; Integrated Photonics; Liquid Cry

  2. Gas ionization by focused laser beams

    International Nuclear Information System (INIS)

    Brito, A.L. de.

    1984-01-01

    It is shown that the effect of line broadening by focusing may considerably contribute to the observed laser-induced ionization of gases when the ionization energy of the gas molecules is well above the mean photon energy of the laser radiation. (Author) [pt

  3. Toward biomaterial-based implantable photonic devices

    Directory of Open Access Journals (Sweden)

    Humar Matjaž

    2017-03-01

    Full Text Available Optical technologies are essential for the rapid and efficient delivery of health care to patients. Efforts have begun to implement these technologies in miniature devices that are implantable in patients for continuous or chronic uses. In this review, we discuss guidelines for biomaterials suitable for use in vivo. Basic optical functions such as focusing, reflection, and diffraction have been realized with biopolymers. Biocompatible optical fibers can deliver sensing or therapeutic-inducing light into tissues and enable optical communications with implanted photonic devices. Wirelessly powered, light-emitting diodes (LEDs and miniature lasers made of biocompatible materials may offer new approaches in optical sensing and therapy. Advances in biotechnologies, such as optogenetics, enable more sophisticated photonic devices with a high level of integration with neurological or physiological circuits. With further innovations and translational development, implantable photonic devices offer a pathway to improve health monitoring, diagnostics, and light-activated therapies.

  4. Multimode model for projective photon-counting measurements

    International Nuclear Information System (INIS)

    Tualle-Brouri, Rosa; Ourjoumtsev, Alexei; Dantan, Aurelien; Grangier, Philippe; Wubs, Martijn; Soerensen, Anders S.

    2009-01-01

    We present a general model to account for the multimode nature of the quantum electromagnetic field in projective photon-counting measurements. We focus on photon-subtraction experiments, where non-Gaussian states are produced conditionally. These are useful states for continuous-variable quantum-information processing. We present a general method called mode reduction that reduces the multimode model to an effective two-mode problem. We apply this method to a multimode model describing broadband parametric down-conversion, thereby improving the analysis of existing experimental results. The main improvement is that spatial and frequency filters before the photon detector are taken into account explicitly. We find excellent agreement with previously published experimental results, using fewer free parameters than before, and discuss the implications of our analysis for the optimized production of states with negative Wigner functions.

  5. Spinal sagittal balance substantially influences locomotive syndrome and physical performance in community-living middle-aged and elderly women.

    Science.gov (United States)

    Muramoto, Akio; Imagama, Shiro; Ito, Zenya; Hirano, Kenichi; Ishiguro, Naoki; Hasegawa, Yukiharu

    2016-03-01

    Spinal sagittal imbalance has been well known risk factor of decreased quality of life in the field of adult spinal deformity. However, the impact of spinal sagittal balance on locomotive syndrome and physical performance in community-living elderly has not yet been clarified. The present study investigated the influence of spinal sagittal alignment on locomotive syndrome (LS) and physical performance in community-living middle-aged and elderly women. A total of 125 women between the age of 40-88 years (mean 66.2 ± 9.7 years) who completed the questionnaires, spinal mouse test, physical examination and physical performance tests in Yakumo study were enrolled in this study. Participants answered the 25-Question Geriatric Locomotive Function Scale (GLFS-25), the visual analog scale (VAS) for low back pain (LBP), knee pain. LS was defined as having a score of >16 points on the GLFS-25. Using spinal mouse, spinal inclination angle (SIA), thoracic kyphosis angle (TKA), lumbar lordosis angle (LLA), sacral slope angle (SSA), thoracic spinal range of motion (TSROM), lumbar spinal range of motion (LSROM) were measured. Timed-up-and-go test (TUG), one-leg standing time with eyes open (OLS), and maximum stride, back muscle strength were also measured. The relationship between spinal sagittal parameters and GLFS-25, VAS and physical performance tests were analyzed. 26 people were diagnosed as LS and 99 were diagnosed as non-LS. LBP and knee pain were greater, physical performance tests were poorer, SIA were greater, LLA were smaller in LS group compared to non-LS group even after adjustment by age. SIA significantly correlated with GLFS-25, TUG, OLS and maximum stride even after adjustment by age. The cutoff value of SIA for locomotive syndrome was 6°. People with a SIA of 6° or greater were grouped as "Inclined" and people with a SIA of less than 6° were grouped as "Non-inclined". 21 people were "Inclined" and 104 were "Non-inclined". Odds ratio to fall in LS of

  6. Luneburg lens in silicon photonics.

    Science.gov (United States)

    Di Falco, Andrea; Kehr, Susanne C; Leonhardt, Ulf

    2011-03-14

    The Luneburg lens is an aberration-free lens that focuses light from all directions equally well. We fabricated and tested a Luneburg lens in silicon photonics. Such fully-integrated lenses may become the building blocks of compact Fourier optics on chips. Furthermore, our fabrication technique is sufficiently versatile for making perfect imaging devices on silicon platforms.

  7. Heavy quark pair production in polarized photon-photon collisions

    International Nuclear Information System (INIS)

    Jikia, G.; Tkabladze, A.

    2000-04-01

    We present the cross sections of the heavy quark-antiquark pair production in polarized photon photon collision for the general case of photon polarizations. The numerical results for top-antitop production cross sections together with production asymmetries are obtained for linearly polarized photon-photon collisions, including QCD radiative corrections. (orig.)

  8. Photon-photon collisions and photon structure functions at LEP

    CERN Document Server

    Patt, J

    2000-01-01

    The present knowledge of the structure of the photon based on measurements of photon structure functions is discussed. This review covers recent results on QED structure functions and on the hadronic structure function F/sub 2//sup gamma /. (13 refs).

  9. CMOS-compatible photonic devices for single-photon generation

    Directory of Open Access Journals (Sweden)

    Xiong Chunle

    2016-09-01

    Full Text Available Sources of single photons are one of the key building blocks for quantum photonic technologies such as quantum secure communication and powerful quantum computing. To bring the proof-of-principle demonstration of these technologies from the laboratory to the real world, complementary metal–oxide–semiconductor (CMOS-compatible photonic chips are highly desirable for photon generation, manipulation, processing and even detection because of their compactness, scalability, robustness, and the potential for integration with electronics. In this paper, we review the development of photonic devices made from materials (e.g., silicon and processes that are compatible with CMOS fabrication facilities for the generation of single photons.

  10. On the theory of spatial localization of photons

    International Nuclear Information System (INIS)

    Keller, Ole

    2005-01-01

    In the quantum physics of near-field optics and optical tunneling light-matter interactions are studied on a length scale (much) smaller than the wavelength of light, and questions regarding the possibilities for strong spatial localization of electromagnetic fields are here in focus. Some of these questions relate to the spatial resolution problem in optics, a problem which has gained considerable attention in connection to optical investigations of mesoscopic systems. Optics beyond the classical diffraction limit has renewed our interest in the various theories for spatial localization of single photons. In the present work aspects of these theories of particular importance for light-matter interaction on the microscopic and mesoscopic length scales are reviewed. Photon wave mechanics, i.e. the (rather unknown) first quantized theory of the photon, allows us to address the spatial field localization problem in a flexible manner which links smoothly to classical electromagnetics. The wave mechanics of free photons is discussed both in the momentum-time domain (Part A) and in the space-time domain (Part B). The first-quantized theory of spatial localization of photons subjected to field-matter interaction is described in Part C, paying particular attendance to the so-called photon energy wave function concept. In Part D, the spatial localization of photons are studied on a field theoretic (second-quantized) basis. The coarse-grained photon localization theory and the spatial localization perceived in various representations (gauges) here are core issues. In the two last parts of the review I describe photon fields in near-field optics (Part E), and the optical tunneling phenomenon, here seen as a fingerprint of weak photon localizability (Part F)

  11. Photonics

    CERN Document Server

    Andrews, David L

    2015-01-01

    This book covers modern photonics accessibly and discusses the basic physical principles underlying all the applications and technology of photonicsThis volume covers the basic physical principles underlying the technology and all applications of photonics from statistical optics to quantum optics. The topics discussed in this volume are: Photons in perspective; Coherence and Statistical Optics; Complex Light and Singular Optics; Electrodynamics of Dielectric Media; Fast and slow Light; Holography; Multiphoton Processes; Optical Angular Momentum; Optical Forces, Trapping and Manipulation; Pol

  12. Nanomanipulation using near field photonics.

    Science.gov (United States)

    Erickson, David; Serey, Xavier; Chen, Yih-Fan; Mandal, Sudeep

    2011-03-21

    In this article we review the use of near-field photonics for trapping, transport and handling of nanomaterials. While the advantages of traditional optical tweezing are well known at the microscale, direct application of these techniques to the handling of nanoscale materials has proven difficult due to unfavourable scaling of the fundamental physics. Recently a number of research groups have demonstrated how the evanescent fields surrounding photonic structures like photonic waveguides, optical resonators, and plasmonic nanoparticles can be used to greatly enhance optical forces. Here, we introduce some of the most common implementations of these techniques, focusing on those which have relevance to microfluidic or optofluidic applications. Since the field is still relatively nascent, we spend much of the article laying out the fundamental and practical advantages that near field optical manipulation offers over both traditional optical tweezing and other particle handling techniques. In addition we highlight three application areas where these techniques namely could be of interest to the lab-on-a-chip community, namely: single molecule analysis, nanoassembly, and optical chromatography. This journal is © The Royal Society of Chemistry 2011

  13. Multi-photon absorption limits to heralded single photon sources

    Science.gov (United States)

    Husko, Chad A.; Clark, Alex S.; Collins, Matthew J.; De Rossi, Alfredo; Combrié, Sylvain; Lehoucq, Gaëlle; Rey, Isabella H.; Krauss, Thomas F.; Xiong, Chunle; Eggleton, Benjamin J.

    2013-01-01

    Single photons are of paramount importance to future quantum technologies, including quantum communication and computation. Nonlinear photonic devices using parametric processes offer a straightforward route to generating photons, however additional nonlinear processes may come into play and interfere with these sources. Here we analyse spontaneous four-wave mixing (SFWM) sources in the presence of multi-photon processes. We conduct experiments in silicon and gallium indium phosphide photonic crystal waveguides which display inherently different nonlinear absorption processes, namely two-photon (TPA) and three-photon absorption (ThPA), respectively. We develop a novel model capturing these diverse effects which is in excellent quantitative agreement with measurements of brightness, coincidence-to-accidental ratio (CAR) and second-order correlation function g(2)(0), showing that TPA imposes an intrinsic limit on heralded single photon sources. We build on these observations to devise a new metric, the quantum utility (QMU), enabling further optimisation of single photon sources. PMID:24186400

  14. Non-Poissonian photon statistics from macroscopic photon cutting materials.

    Science.gov (United States)

    de Jong, Mathijs; Meijerink, Andries; Rabouw, Freddy T

    2017-05-24

    In optical materials energy is usually extracted only from the lowest excited state, resulting in fundamental energy-efficiency limits such as the Shockley-Queisser limit for single-junction solar cells. Photon-cutting materials provide a way around such limits by absorbing high-energy photons and 'cutting' them into multiple low-energy excitations that can subsequently be extracted. The occurrence of photon cutting or quantum cutting has been demonstrated in a variety of materials, including semiconductor quantum dots, lanthanides and organic dyes. Here we show that photon cutting results in bunched photon emission on the timescale of the excited-state lifetime, even when observing a macroscopic number of optical centres. Our theoretical derivation matches well with experimental data on NaLaF 4 :Pr 3+ , a material that can cut deep-ultraviolet photons into two visible photons. This signature of photon cutting can be used to identify and characterize new photon-cutting materials unambiguously.

  15. Contributions of individual muscles to the sagittal- and frontal-plane angular accelerations of the trunk in walking.

    Science.gov (United States)

    Klemetti, Rudolf; Steele, Katherine M; Moilanen, Petro; Avela, Janne; Timonen, Jussi

    2014-07-18

    This study was conducted to analyze the unimpaired control of the trunk during walking. Studying the unimpaired control of the trunk reveals characteristics of good control. These characteristics can be pursued in the rehabilitation of impaired control. Impaired control of the trunk during walking is associated with aging and many movement disorders. This is a concern as it is considered to increase fall risk. Muscles that contribute to the trunk control in normal walking may also contribute to it under perturbation circumstances, attempting to prevent an impending fall. Knowledge of such muscles can be used to rehabilitate impaired control of the trunk. Here, angular accelerations of the trunk induced by individual muscles, in the sagittal and frontal planes, were calculated using 3D muscle-driven simulations of seven young healthy subjects walking at free speed. Analysis of the simulations demonstrated that the abdominal and back muscles displayed large contributions throughout the gait cycle both in the sagittal and frontal planes. Proximal lower-limb muscles contributed more than distal muscles in the sagittal plane, while both proximal and distal muscles showed large contributions in the frontal plane. Along with the stance-limb muscles, the swing-limb muscles also exhibited considerable contribution. The gluteus medius was found to be an important individual frontal-plane control muscle; enhancing its function in pathologies could ameliorate gait by attenuating trunk sway. In addition, since gravity appreciably accelerated the trunk in the frontal plane, it may engender excessive trunk sway in pathologies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Correlation Between Lumbopelvic and Sagittal Parameters and Health-Related Quality of Life in Adults With Lumbosacral Spondylolisthesis.

    Science.gov (United States)

    Gussous, Yazeed; Theologis, Alexander A; Demb, Joshua B; Tangtiphaiboontana, Jennifer; Berven, Sigurd

    2018-02-01

    Secondary analysis of prospective, multicenter data. To evaluate impact of sagittal parameters on health-related quality of life (HRQoL) in adults with lumbosacral spondylolisthesis. Adults with unoperated lumbosacral spondylolisthesis were identified in the Spinal Deformity Study Group database. Pearson's correlations were calculated between SF-12 (Short Form-12)/Scoliosis Research Society-30 (SRS-30) scores and radiographic parameters (C7 sagittal vertical axis [SVA] deviation, T1 pelvic angle, pelvic tilt [PT], pelvic incidence, sacral slope, slip angle, Meyerding slip grade, Labelle classification). Main effects linear regression models measured association between individual health status measures and individual radiographic predictor variables. Forty-five patients were analyzed (male, 15; female, 30; average age 40.5 ± 18.7 years; 14 low-grade, 31 high-grade). For low-grade slips, SVA had strong negative correlations with SF-12 mental component score (MCS), SRS-30 appearance, mental, and satisfaction domains ( r = -0.57, r = -0.60, r = -0.58, r = -0.53, respectively; P grade slips, slip angle had a moderate negative correlation with SF-12 MCS ( r = -0.36; P = .05) and SVA had strong negative correlations with SF-12 physical component score (PCS), SRS-30 appearance and activity domains ( r = -0.48, r = -0.48, r = -0.45; P point decrease in SRS appearance, 0.05-point decrease in SRS activity, 0.06-point decrease in SRS satisfaction, and 0.04-point decrease in SRS total score ( P grade slips. Improvement of sagittal parameters is an important goal of surgery for adults with lumbosacral spondylolisthesis.

  17. Brief communication: age and fractal dimensions of human sagittal and coronal sutures

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Jacobsen, Jens Christian Brings

    2003-01-01

    The fractal dimensions of human sagittal and coronal sutures were calculated on 31 complete skulls from the Terry Collection. The aim was to investigate whether the fractal dimension, relying on the whole sutural length, might yield a better description of age-related changes in sutural morphology......, as opposed to other methods of quantification, which generally rely on more arbitrary scoring systems. However, the fractal dimension did not yield better age correlations than other previously described methods. At best, the results reflected the general observation that young adults below age 40 years...

  18. Coherent beam control through inhomogeneous media in multi-photon microscopy

    Science.gov (United States)

    Paudel, Hari Prasad

    Multi-photon fluorescence microscopy has become a primary tool for high-resolution deep tissue imaging because of its sensitivity to ballistic excitation photons in comparison to scattered excitation photons. The imaging depth of multi-photon microscopes in tissue imaging is limited primarily by background fluorescence that is generated by scattered light due to the random fluctuations in refractive index inside the media, and by reduced intensity in the ballistic focal volume due to aberrations within the tissue and at its interface. We built two multi-photon adaptive optics (AO) correction systems, one for combating scattering and aberration problems, and another for compensating interface aberrations. For scattering correction a MEMS segmented deformable mirror (SDM) was inserted at a plane conjugate to the objective back-pupil plane. The SDM can pre-compensate for light scattering by coherent combination of the scattered light to make an apparent focus even at a depths where negligible ballistic light remains (i.e. ballistic limit). This problem was approached by investigating the spatial and temporal focusing characteristics of a broad-band light source through strongly scattering media. A new model was developed for coherent focus enhancement through or inside the strongly media based on the initial speckle contrast. A layer of fluorescent beads under a mouse skull was imaged using an iterative coherent beam control method in the prototype two-photon microscope to demonstrate the technique. We also adapted an AO correction system to an existing in three-photon microscope in a collaborator lab at Cornell University. In the second AO correction approach a continuous deformable mirror (CDM) is placed at a plane conjugate to the plane of an interface aberration. We demonstrated that this "Conjugate AO" technique yields a large field-of-view (FOV) advantage in comparison to Pupil AO. Further, we showed that the extended FOV in conjugate AO is maintained over a

  19. FDTD Modeling of Nano- and Bio-Photonic Imaging

    DEFF Research Database (Denmark)

    Tanev, Stoyan; Tuchin, Valery; Pond, James

    2010-01-01

    to address newly emerging problems and not so much on its mathematical formulation. We will first discuss the application of a traditional formulation of the FDTD approach to the modeling of sub-wavelength photonics structures. Next, a modified total/scattered field FDTD approach will be applied...... to the modeling of biophotonics applications including Optical Phase Contrast Microscope (OPCM) imaging of cells containing gold nanoparticles (NPs) as well as its potential application as a modality for in vivo flow cytometry configurations.......In this paper we focus on the discussion of two recent unique applications of the Finite-Difference Time-Domain (FDTD) simulation method to the design and modeling of advanced nano- and bio-photonic problems. The approach that is adopted here focuses on the potential of the FDTD methodology...

  20. Neuromorphic photonic networks using silicon photonic weight banks.

    Science.gov (United States)

    Tait, Alexander N; de Lima, Thomas Ferreira; Zhou, Ellen; Wu, Allie X; Nahmias, Mitchell A; Shastri, Bhavin J; Prucnal, Paul R

    2017-08-07

    Photonic systems for high-performance information processing have attracted renewed interest. Neuromorphic silicon photonics has the potential to integrate processing functions that vastly exceed the capabilities of electronics. We report first observations of a recurrent silicon photonic neural network, in which connections are configured by microring weight banks. A mathematical isomorphism between the silicon photonic circuit and a continuous neural network model is demonstrated through dynamical bifurcation analysis. Exploiting this isomorphism, a simulated 24-node silicon photonic neural network is programmed using "neural compiler" to solve a differential system emulation task. A 294-fold acceleration against a conventional benchmark is predicted. We also propose and derive power consumption analysis for modulator-class neurons that, as opposed to laser-class neurons, are compatible with silicon photonic platforms. At increased scale, Neuromorphic silicon photonics could access new regimes of ultrafast information processing for radio, control, and scientific computing.

  1. Sci-Thur AM: YIS – 03: Combining sagittally-reconstructed 3D and live-2D ultrasound for high-dose-rate prostate brachytherapy needle segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Hrinivich, Thomas; Hoover, Douglas; Surry, Kathleen; Edirisinghe, Chandima; D’Souza, David; Fenster, Aaron; Wong, Eugene [University of Western Ontario, London Regional Cancer Program/LHSC, London Regional Cancer Program/LHSC, Robarts Research Institute, London Regional Cancer Program/LHSC, Robarts Research Institute, University of Western Ontario (Canada)

    2016-08-15

    Ultrasound-guided high-dose-rate prostate brachytherapy (HDR-BT) needle segmentation is performed clinically using live-2D sagittal images. Organ segmentation is then performed using axial images, introducing a source of geometric uncertainty. Sagittally-reconstructed 3D (SR3D) ultrasound enables both needle and organ segmentation, but suffers from shadow artifacts. We present a needle segmentation technique augmenting SR3D with live-2D sagittal images using mechanical probe tracking to mitigate image artifacts and compare it to the clinical standard. Seven prostate cancer patients underwent TRUS-guided HDR-BT during which the clinical and proposed segmentation techniques were completed in parallel using dual ultrasound video outputs. Calibrated needle end-length measurements were used to calculate insertion depth errors (IDEs), and the dosimetric impact of IDEs was evaluated by perturbing clinical treatment plan source positions. The proposed technique provided smaller IDEs than the clinical approach, with mean±SD of −0.3±2.2 mm and −0.5±3.7mm respectively. The proposed and clinical techniques resulted in 84% and 43% of needles with IDEs within ±3mm, and IDE ranges across all needles of [−7.7mm, 5.9mm] and [−9.3mm, 7.7mm] respectively. The proposed and clinical IDEs lead to mean±SD changes in the volume of the prostate receiving the prescription dose of −0.6±0.9% and −2.0±5.3% respectively. The proposed technique provides improved HDR-BT needle segmentation accuracy over the clinical technique leading to decreased dosimetric uncertainty by eliminating the axial-to-sagittal registration, and mitigates the effect of shadow artifacts by incorporating mechanically registered live-2D sagittal images.

  2. Microwave background constraints on mixing of photons with hidden photons

    International Nuclear Information System (INIS)

    Mirizzi, Alessandro; Redondo, Javier; Sigl, Guenter

    2008-12-01

    Various extensions of the Standard Model predict the existence of hidden photons kinetically mixing with the ordinary photon. This mixing leads to oscillations between photons and hidden photons, analogous to the observed oscillations between different neutrino flavors. In this context, we derive new bounds on the photon-hidden photon mixing parameters using the high precision cosmic microwave background spectral data collected by the Far Infrared Absolute Spectrophotometer instrument on board of the Cosmic Background Explorer. Requiring the distortions of the CMB induced by the photon-hidden photon mixing to be smaller than experimental upper limits, this leads to a bound on the mixing angle χ 0 -7 - 10 -5 for hidden photon masses between 10 -14 eV and 10 -7 eV. This low-mass and low-mixing region of the hidden photon parameter space was previously unconstrained. (orig.)

  3. Compact scanning transmission x-ray microscope at the photon factory

    International Nuclear Information System (INIS)

    Takeichi, Yasuo; Inami, Nobuhito; Ono, Kanta; Suga, Hiroki; Takahashi, Yoshio

    2016-01-01

    We report the design and performance of a compact scanning transmission X-ray microscope developed at the Photon Factory. Piezo-driven linear stages are used as coarse stages of the microscope to realize excellent compactness, mobility, and vibrational and thermal stability. An X-ray beam with an intensity of ∼10 7 photons/s was focused to a diameter of ∼40 nm at the sample. At the soft X-ray undulator beamline used with the microscope, a wide range of photon energies (250–1600 eV) is available. The microscope has been used to research energy materials and in environmental sciences

  4. Photon-photon inclusive scattering and perturbative QCD

    International Nuclear Information System (INIS)

    Maor, U.

    1988-01-01

    Perturbative QCD expectations and problems associated with the study of the photon structure function data are reviewed. An assessment is given for the viability and sensitivity of photon-photon scattering as a decisive tool for the determination of the QCD scale. Particular attention is given to the theoretical problems of singularity cancellations at x = 0 and threshold-associated difficulties at x = 1 and their implications on the actual data analysis. It is concluded that the experimental results, while not providing a decisive verification of QCD at small distances, do add to other independent experiments which are all consistent with the theory and suggest a reasonably well defined QCD scale parameter. The importance of the small Q 2 limit to photon-photon analysis is discussed and the data are examined in an attempt to identify and isolate the contributions of the hadronic and point-like sectors of the target photon. 21 refs., 7 figs. (author)

  5. Limitations of two-level emitters as nonlinearities in two-photon controlled-PHASE gates

    DEFF Research Database (Denmark)

    Nysteen, Anders; McCutcheon, Dara P. S.; Heuck, Mikkel

    2017-01-01

    We investigate the origin of imperfections in the fidelity of a two-photon controlled-PHASE gate based on two-level-emitter nonlinearities. We focus on a passive system that operates without external modulations to enhance its performance. We demonstrate that the fidelity of the gate is limited...... by opposing requirements on the input pulse width for one-and two-photon-scattering events. For one-photon scattering, the spectral pulse width must be narrow compared with the emitter linewidth, while two-photon-scattering processes require the pulse width and emitter linewidth to be comparable. We find...

  6. Photons in Natural and Life Sciences An Interdisciplinary Approach

    CERN Document Server

    Lewerenz, Hans-Joachim

    2012-01-01

    The book describes first the principle photon generation processes from nuclear reactions, electron motion and from discrete quantum transitions. It then focuses on the use of photons in various selected fields of modern natural and life sciences. It bridges disciplines such as physics, chemistry, earth- and materials science, proteomics, information technology, photoelectrochemistry, photosynthesis and spintronics. Advanced light sources and their use in natural and life sciences are emphasized and the effects related to the quantum nature of photons (quantum computing, teleportation) are described. The content encompasses among many other examples the role of photons on the origin of life and on homochirality in biology, femtosecond laser slicing, photothermal cancer therapy, the use of gamma rays in materials science, photoelectrochemical surface conditioning, quantum information aspects and photo-spintronics. The book is written for scientists and graduate students from all related disciplines who are int...

  7. Microwave background constraints on mixing of photons with hidden photons

    Energy Technology Data Exchange (ETDEWEB)

    Mirizzi, Alessandro [Max-Planck-Institut fuer Physik, Muenchen (Germany); Redondo, Javier [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Sigl, Guenter [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik

    2008-12-15

    Various extensions of the Standard Model predict the existence of hidden photons kinetically mixing with the ordinary photon. This mixing leads to oscillations between photons and hidden photons, analogous to the observed oscillations between different neutrino flavors. In this context, we derive new bounds on the photon-hidden photon mixing parameters using the high precision cosmic microwave background spectral data collected by the Far Infrared Absolute Spectrophotometer instrument on board of the Cosmic Background Explorer. Requiring the distortions of the CMB induced by the photon-hidden photon mixing to be smaller than experimental upper limits, this leads to a bound on the mixing angle {chi}{sub 0}

  8. Complex photonic structures for energy efficiency

    Directory of Open Access Journals (Sweden)

    Wiersma D. S.

    2013-06-01

    Full Text Available Photonic structures are playing an increasingly important role in energy efficiency. In particular, they can help to control the flow of light and improve the optical properties of photovoltaic solar cells. We will explain the physics of light transport in such structures with a special focus on disordered materials.

  9. CHARACTERISTICS OF BODY POSTURE IN THE SAGITTAL PLANE AND FITNESS OF FIRST-FORM PUPILS FROM RURAL AREAS

    Directory of Open Access Journals (Sweden)

    Hanna Żukowska

    2014-07-01

    Full Text Available Purpose: to find correlations between characteristics of body posture in the sagittal plane and fitness and endurance of first-form children from rural areas. Material: an analysis of more than 30 sources of scientific and educational literature. Results: the study involved 209 children, including 102 girls and 107 boys. They were children who lived in the country since they were born. To assess particular characteristics of body posture, the children were studied by means of the measuring equipment using the projection Moiré system. Motor skills were estimated using selected EUROFIT physical fitness tests (sitting forward bend, standing broad jump, handgrip, sit-and-reach, bent arm hang and 10 x 5 m shuttle run. The level of physical endurance was evaluated with the Harvard Step Test modified by Montoye. Conclusions: the conducted research reveals statistically significant correlations between the characteristics of body posture in the sagittal plane and selected EUROFIT physical fitness tests and physical endurance of the children involved in the study.

  10. Kinoform optics applied to X-ray photon correlation spectroscopy.

    Science.gov (United States)

    Sandy, A R; Narayanan, S; Sprung, M; Su, J-D; Evans-Lutterodt, K; Isakovic, A F; Stein, A

    2010-05-01

    Moderate-demagnification higher-order silicon kinoform focusing lenses have been fabricated to facilitate small-angle X-ray photon correlation spectroscopy (XPCS) experiments. The geometric properties of such lenses, their focusing performance and their applicability for XPCS measurements are described. It is concluded that one-dimensional vertical X-ray focusing via silicon kinoform lenses significantly increases the usable coherent flux from third-generation storage-ring light sources for small-angle XPCS experiments.

  11. Cervical sagittal balance parameters after single-level anterior cervical discectomy and fusion: Correlations with clinical and functional outcomes

    Directory of Open Access Journals (Sweden)

    Ioannis Siasios

    2018-01-01

    Conclusions: Single-level ACDF significantly increases upper cervical lordosis (C1–C2 without significantly changing lower cervical lordosis (C2–C7. The C7 slope is a significant marker of overall cervical sagittal alignment (P < 0.05.

  12. Photonic crystal based polarization insensitive flat lens

    International Nuclear Information System (INIS)

    Turduev, M; Bor, E; Kurt, H

    2017-01-01

    The paper proposes a new design of an inhomogeneous artificially created photonic crystal lens structure consisting of annular dielectric rods to efficiently focus both transverse electric and transverse magnetic polarizations of light into the same focal point. The locations of each individual cell that contains the annular dielectric rods are determined according to a nonlinear distribution function. The inner and outer radii of the annular photonic dielectric rods are optimized with respect to the polarization insensitive frequency response of the transmission spectrum of the lens structure. The physical background of the polarization insensitive focusing mechanism is investigated in both spatial and frequency domains. Moreover, polarization independent wavefront transformation/focusing has been explored in detail by investigating the dispersion relation of the structure. Corresponding phase index distribution of the lens is attained for polarization insensitive normalized frequency range of a / λ   =  0.280 and a / λ   =  0.300, where a denotes the lattice constant of the designed structure and λ denotes the wavelength of the incident light. We show the wave transformation performance and focal point movement dynamics for both polarizations of the lens structure by specially adjusting the length of the structure. The 3D finite-difference time domain numerical analysis is also performed to verifiy that the proposed design is able to focus the wave regardless of polarization into approximately the same focal point (difference between focal distances of both polarizations stays below 0.25 λ ) with an operating bandwidth of 4.30% between 1476 nm and 1541 nm at telecom wavelengths. The main superiorities of the proposed lens structure are being all dielectric and compact, and having flat front and back surfaces, rendering the proposed lens design more practical in the photonic integration process in various applications such as optical switch

  13. Maximum likelihood-based analysis of single-molecule photon arrival trajectories

    Science.gov (United States)

    Hajdziona, Marta; Molski, Andrzej

    2011-02-01

    In this work we explore the statistical properties of the maximum likelihood-based analysis of one-color photon arrival trajectories. This approach does not involve binning and, therefore, all of the information contained in an observed photon strajectory is used. We study the accuracy and precision of parameter estimates and the efficiency of the Akaike information criterion and the Bayesian information criterion (BIC) in selecting the true kinetic model. We focus on the low excitation regime where photon trajectories can be modeled as realizations of Markov modulated Poisson processes. The number of observed photons is the key parameter in determining model selection and parameter estimation. For example, the BIC can select the true three-state model from competing two-, three-, and four-state kinetic models even for relatively short trajectories made up of 2 × 103 photons. When the intensity levels are well-separated and 104 photons are observed, the two-state model parameters can be estimated with about 10% precision and those for a three-state model with about 20% precision.

  14. Maximum likelihood-based analysis of single-molecule photon arrival trajectories.

    Science.gov (United States)

    Hajdziona, Marta; Molski, Andrzej

    2011-02-07

    In this work we explore the statistical properties of the maximum likelihood-based analysis of one-color photon arrival trajectories. This approach does not involve binning and, therefore, all of the information contained in an observed photon strajectory is used. We study the accuracy and precision of parameter estimates and the efficiency of the Akaike information criterion and the Bayesian information criterion (BIC) in selecting the true kinetic model. We focus on the low excitation regime where photon trajectories can be modeled as realizations of Markov modulated Poisson processes. The number of observed photons is the key parameter in determining model selection and parameter estimation. For example, the BIC can select the true three-state model from competing two-, three-, and four-state kinetic models even for relatively short trajectories made up of 2 × 10(3) photons. When the intensity levels are well-separated and 10(4) photons are observed, the two-state model parameters can be estimated with about 10% precision and those for a three-state model with about 20% precision.

  15. Modeling and Development of Superconducting Nanowire Single Photon Detectors

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal outlines a research project as the central component of a Ph.D. program focused on the device physics of superconducting nanowire single photon...

  16. On the validity of the equivalent-photon approximation for virtual photon-photon collisions

    International Nuclear Information System (INIS)

    Carimalo, C.; Kessler, P.; Parisi, J.

    1979-05-01

    For virtual photon-photon collisions in electron storage rings, one derive the equivalent-photon approximation from a helicity treatment, and present it in two forms, involving respectively (i) polarized transverse photons ('transverse-photon approximation') and (ii) unpolarized ones ('Williams-Weizsaecker approximation'). One first postulates the conditions of validity of the approximation on the basis of analytic considerations, and then check them numerically in the case of the process e e → e e μ + μ - . For this check, we consider the completely differentiated cross section as far as approximation (i) is concerned; and in the case of approximation (ii), the cross section differentiated with respect to all variables except the azimuthal angles. The results are given in the form of Tables showing the lower and higher limit of the error involved in the approximation for a large variety of kinematic configurations (i. e., energy losses and scattering angles of both electrons). Those Tables are discussed in detail, and conclusions are drawn as to the applicability of the equivalent-photon approximation to future experiments to be performed with high-energy electron storage rings

  17. gPhoton: THE GALEX PHOTON DATA ARCHIVE

    Energy Technology Data Exchange (ETDEWEB)

    Million, Chase [Million Concepts LLC, P.O. Box 119, 141 Mary Street, Lemont, PA 16851 (United States); Fleming, Scott W.; Shiao, Bernie; Smith, Myron; Thompson, Randy; White, Richard L. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Seibert, Mark [The Observatories of the Carnegie Institution of Washington, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Loyd, Parke [Laboratory for Atmospheric and Space Physics, Boulder, Colorado, 80309 (United States); Tucker, Michael [Dept. of Physics and Astronomy, Appalachian State University, Boone, NC 28608 (United States)

    2016-12-20

    gPhoton is a new database product and software package that enables analysis of GALEX ultraviolet data at the photon level. The project’s stand-alone, pure-Python calibration pipeline reproduces the functionality of the original mission pipeline to reduce raw spacecraft data to lists of time-tagged, sky-projected photons, which are then hosted in a publicly available database by the Mikulski Archive at Space Telescope. This database contains approximately 130 terabytes of data describing approximately 1.1 trillion sky-projected events with a timestamp resolution of five milliseconds. A handful of Python and command-line modules serve as a front end to interact with the database and to generate calibrated light curves and images from the photon-level data at user-defined temporal and spatial scales. The gPhoton software and source code are in active development and publicly available under a permissive license. We describe the motivation, design, and implementation of the calibration pipeline, database, and tools, with emphasis on divergence from prior work, as well as challenges created by the large data volume. We summarize the astrometric and photometric performance of gPhoton relative to the original mission pipeline. For a brief example of short time-domain science capabilities enabled by gPhoton, we show new flares from the known M-dwarf flare star CR Draconis. The gPhoton software has permanent object identifiers with the ASCL (ascl:1603.004) and DOI (doi:10.17909/T9CC7G). This paper describes the software as of version v1.27.2.

  18. Photon-Photon Luminosities in Relativistic Heavy Ion Collisions at LHC Energies

    OpenAIRE

    Hencken, Kai; Trautmann, Dirk; Baur, Gerhard

    1994-01-01

    Effective photon-photon luminosities are calculated for various realistic hadron collider scenarios. The main characteristics of photon-photon processes at relativistic heavy-ion colliders are established and compared to the corresponding photon-photon luminosities at electron-positron and future Photon Linear Colliders (PLC). Higher order corrections as well as inelastic processes are discussed. It is concluded that feasible high luminosity Ca-Ca collisions at the Large Hadron Collider (LHC)...

  19. Sagittal plane gait characteristics in hip osteoarthritis patients with mild to moderate symptoms compared to healthy controls: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Eitzen Ingrid

    2012-12-01

    Full Text Available Abstract Background Existent biomechanical studies on hip osteoarthritic gait have primarily focused on the end stage of disease. Consequently, there is no clear consensus on which specific gait parameters are of most relevance for hip osteoarthritis patients with mild to moderate symptoms. The purpose of this study was to explore sagittal plane gait characteristics during the stance phase of gait in hip osteoarthritis patients not eligible for hip replacement surgery. First, compared to healthy controls, and second, when categorized into two subgroups of radiographic severity defined from a minimal joint space of ≤/>2 mm. Methods Sagittal plane kinematics and kinetics of the hip, knee and ankle joint were calculated for total joint excursion throughout the stance phase, as well as from the specific events initial contact, midstance, peak hip extension and toe-off following 3D gait analysis. In addition, the Western Ontario and McMaster Universities Osteoarthritis Index, passive hip range of motion, and isokinetic muscle strength of hip and knee flexion and extension were included as secondary outcomes. Data were checked for normality and differences evaluated with the independent Student’s t-test, Welch’s t-test and the independent Mann–Whitney U-test. A binary logistic regression model was used in order to control for velocity in key variables. Results Fourty-eight hip osteoarthritis patients and 22 controls were included in the final material. The patients walked significantly slower than the controls (p=0.002, revealed significantly reduced joint excursions of the hip (pp=0.011, and a reduced hip flexion moment at midstance and peak hip extension (p2 mm suggested that the observed deviations were more pronounced in patients with greater radiographic severity. The biomechanical differences were, however, not reflected in self-reported symptoms or function. Conclusions Reduced gait velocity, reduced sagittal plane joint excursion, and

  20. Direct sagittal CT scanning in the diagnosis of pituitary fossa tumours and posterior fossa pathology

    International Nuclear Information System (INIS)

    Podlas, H.

    1981-01-01

    Two independent methods are presented for multidirectional CT scanning of the brain using the Philips Tomoscan 300. The advantages in scanning pituitary fossa tumours and pathology of the posterior fossa are discussed. No additional software or modifications are required. Direct sagittal scanning is particularly advantageous for accurate assessment of the size of pituitary tumours and intrasellar lesions requiring surgical intervention or radiation therapy. (Auth.)

  1. Sagittal Thoracic and Lumbar Spine Profiles in Upright Standing and Lying Prone Positions Among Healthy Subjects: Influence of Various Biometric Features.

    Science.gov (United States)

    Salem, Walid; Coomans, Ysaline; Brismée, Jean-Michel; Klein, Paul; Sobczak, Stéphane; Dugailly, Pierre-Michel

    2015-08-01

    A prospective study was performed on the assessment of both thoracic and lumbar spine sagittal profiles (from C7 to S1). To propose a new noninvasive method for measuring the spine curvatures in standing and lying prone positions and to analyze their relationship with various biometric characteristics. Modifications of spine curvatures (i.e. lordosis or kyphosis) are of importance in the development of spinal disorders. Studies have emphasized the development of new devices to measure the spine sagittal profiles using a noninvasive and low-cost method. To date, it has not been applied for analyzing both lumbar and thoracic alterations for various positioning. Seventy-five healthy subjects (mean 22.6 ± 4.3 yr) were recruited to participate in this study. Thoracic and lumbar sagittal profiles were assessed in standing and lying prone positions using a 3D digitizer. In addition, several biometric data were collected including maximal trunk isometric strength for flexion and extension movement. Statistical analysis consisted in data comparisons of spine profiles and a multivariate analysis including biometric features, to classify individuals considering low within- and high between-variability. Kyphosis and lordosis angles decreased significantly from standing to lying prone position by an average of 13.4° and 16.6°, respectively. Multivariate analysis showed a sample clustering of 3 homogenous subgroups. The first group displayed larger lordosis and flexibility, and had low data values for height, weight, and strength. The second group had lower values than the overall trend of the whole sample, whereas the third group had larger score values for the torques, height, weight, waist, body mass index, and kyphosis angle but a reduced flexibility. The present results demonstrate a significant effect of the positioning on both thoracic and lumbar spine sagittal profiles and highlight the use of cluster analysis to categorize subgroups after biometric characteristics

  2. Evaluation of Andrews' Analysis as a Predictor of Ideal Sagittal Maxillary Positioning in Orthognathic Surgery.

    Science.gov (United States)

    Resnick, Cory M; Kim, Somi; Yorlets, Rachel R; Calabrese, Carly E; Peacock, Zachary S; Kaban, Leonard B

    2018-03-22

    There is no universally accepted method for determining the ideal sagittal position of the maxilla in orthognathic surgery. In "Element II" of "The Six Elements of Orofacial Harmony," Andrews used the forehead to define the goal maxillary position. The purpose of this study was to compare how well this analysis correlated with postoperative findings in patients who underwent bimaxillary orthognathic surgery planned using other guidelines. The authors hypothesized that the Andrews analysis would more consistently reflect clinical outcomes than standard angular and linear measurements. This is a retrospective cohort study of patients who had bimaxillary orthognathic surgery and achieved an acceptable esthetic outcome. Patients with no maxillary sagittal movement, obstructive sleep apnea, cleft or craniofacial diagnoses, or who were non-Caucasian were excluded. Treatment plans were developed using photographs, radiographs, and standard cephalometric measurements. The Andrews analysis, measuring the distance from the maxillary incisor to the goal anterior limit line, and standard measurements were applied to end-treatment records. The Andrews analysis was statistically compared with standard methods. There were 493 patients who had orthognathic surgery from 2007 through 2014, and 60 (62% women; mean age, 22.1 ± 6.8 yr) met the criteria for inclusion in this study. The mean Andrews distances were -4.8 ± 2.9 mm for women and -8.6 ± 4.6 mm for men preoperatively and -0.6 ± 2.1 mm for women and -1.9 ± 3.4 mm for men postoperatively. For women, the Andrews analysis was closer to the goal value (0 mm) postoperatively than any standard measurement (P Andrews analysis. The Andrews analysis correlated well with the final esthetic sagittal maxillary position in the present sample, particularly for women, and could be a useful tool for orthognathic surgical planning. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by

  3. Agreement between fiber optic and optoelectronic systems for quantifying sagittal plane spinal curvature in sitting.

    Science.gov (United States)

    Cloud, Beth A; Zhao, Kristin D; Breighner, Ryan; Giambini, Hugo; An, Kai-Nan

    2014-07-01

    Spinal posture affects how individuals function from a manual wheelchair. There is a need to directly quantify spinal posture in this population to ultimately improve function. A fiber optic system, comprised of an attached series of sensors, is promising for measuring large regions of the spine in individuals sitting in a wheelchair. The purpose of this study was to determine the agreement between fiber optic and optoelectronic systems for measuring spinal curvature, and describe the range of sagittal plane spinal curvatures in natural sitting. Able-bodied adults (n = 26, 13 male) participated. Each participant assumed three sitting postures: natural, slouched (accentuated kyphosis), and extension (accentuated lordosis) sitting. Fiber optic (ShapeTape) and optoelectronic (Optotrak) systems were applied to the skin over spinous processes from S1 to C7 and used to measure sagittal plane spinal curvature. Regions of kyphosis and lordosis were identified. A Cobb angle-like method was used to quantify lordosis and kyphosis. Generalized linear model and Bland-Altman analyses were used to assess agreement. A strong correlation exists between curvature values obtained with Optotrak and ShapeTape (R(2) = 0.98). The mean difference between Optotrak and ShapeTape for kyphosis in natural, extension, and slouched postures was 4.30° (95% LOA: -3.43 to 12.04°), 3.64° (95% LOA: -1.07 to 8.36°), and 4.02° (95% LOA: -2.80 to 10.84°), respectively. The mean difference for lordosis, when present, in natural and extension postures was 2.86° (95% LOA: -1.18 to 6.90°) and 2.55° (95% LOA: -3.38 to 8.48°), respectively. In natural sitting, the mean ± SD of kyphosis values was 35.07 ± 6.75°. Lordosis was detected in 8/26 participants: 11.72 ± 7.32°. The fiber optic and optoelectronic systems demonstrate acceptable agreement for measuring sagittal plane thoracolumbar spinal curvature. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Photon technology. Laser process technology; Photon technology. Laser process gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    For developing laser process technology by interaction between substance and photon, the present state, system, R and D issues and proposal of such technology were summarized. Development of the photon technology aims at the modification of bonding conditions of substances by quantum energy of photon, and the new process technology for generating ultra- high temperature and pressure fields by concentrating photon on a minute region. Photon technology contributes to not only the conventional mechanical and thermal forming and removal machining but also function added machining (photon machining) in quantum level and new machining technology ranging from macro- to micro-machining, creating a new industrial field. This technology extends various fields from the basis of physics and chemistry to new bonding technology. Development of a compact high-quality high-power high-efficiency photon source, and advanced photon transmission technology are necessary. The basic explication of an unsolved physicochemical phenomenon related to photon and substance, and development of related application technologies are essential. 328 refs., 147 figs., 13 tabs.

  5. Two-photon interference of polarization-entangled photons in a Franson interferometer.

    Science.gov (United States)

    Kim, Heonoh; Lee, Sang Min; Kwon, Osung; Moon, Han Seb

    2017-07-18

    We present two-photon interference experiments with polarization-entangled photon pairs in a polarization-based Franson-type interferometer. Although the two photons do not meet at a common beamsplitter, a phase-insensitive Hong-Ou-Mandel type two-photon interference peak and dip fringes are observed, resulting from the two-photon interference effect between two indistinguishable two-photon probability amplitudes leading to a coincidence detection. A spatial quantum beating fringe is also measured for nondegenerate photon pairs in the same interferometer, although the two-photon states have no frequency entanglement. When unentangled polarization-correlated photons are used as an input state, the polarization entanglement is successfully recovered through the interferometer via delayed compensation.

  6. QCD measurements in photon-photon collisions at LEP

    OpenAIRE

    Csilling, Akos

    2001-01-01

    An overview of the latest results of the LEP collaborations on QCD measurements in photon-photon collisions is presented, including measurements of the total hadronic cross-section, the production of heavy quarks and dijets and the structure functions of real and virtual photons.

  7. Nonresonant excess photon detachment of negative hydrogen ions

    International Nuclear Information System (INIS)

    Gulley, M. S.; Zhao, Xin Miao; Bryant, H. C.; Strauss, Charlie E. M.; Funk, David J.; Stintz, A.; Rislove, D. C.; Kyrala, G. A.; Ingalls, W. B.; Miller, W. A.

    1999-01-01

    One-photon detachment and two-photon nonresonant excess photon detachment of electrons from the H - ion (outer-electron binding energy = 0.7542 eV) are observed with 1.165 eV laser pulses from a Nd:YAG laser (where YAG denotes yttrium aluminum garnet). A Penning ion source produces a pulsed 8 μA, 35 keV H - beam that intersects a laser beam cylindrically focused down to a 17 μm full width at half maximum waist in the ion beam direction, creating a high-intensity interaction region with peak intensities of up to 10 11 W/cm 2 . The interaction time is 7 ps. The detached electrons are detected by a time-of-flight apparatus enabling us to detect a very small two-photon signal in the presence of a very large signal from single photon detachments. By rotating the linear polarization angle, we study the angular distribution of the electrons for both one- and two-photon detachments. The spectra are modeled to determine the asymmetry parameters and one- and two-photon cross sections. We find β 2 to be 2.54+0.44/-0.60 and β 4 to be 2.29+0.07/-0.31, corresponding to a D state of 89+3/-12% of the S wave and D wave detachments for the two-photon results. The relative phase angle between the S and D amplitudes is measured to be less than 59 degree sign . The measured cross sections are found to be consistent with theoretical predictions. The one-photon photodetachment cross section is measured to be (3.6±1.7)x10 -17 cm 2 . The two-photon photodetachment generalized cross section is (1.3±0.5)x10 -48 cm 4 sec, consistent with theoretical calculations of the cross section. The three-photon generalized cross section is less than 4.4x10 -79 cm 6 sec 2 . (c) 1999 The American Physical Society

  8. A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife

    International Nuclear Information System (INIS)

    Choi, Tae Jin; Kim, Jin Hee; Kim, Ok Bae

    1996-01-01

    Purpose : To get an acute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic tranmultiarc beam mode based on linear accelerator photon beam. Methods and Materials : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusion : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments. the absorbed dose has been decreased to 27 % /mm in maximum at the interval of 50% to 80% of isodose line

  9. Photonic time crystals.

    Science.gov (United States)

    Zeng, Lunwu; Xu, Jin; Wang, Chengen; Zhang, Jianhua; Zhao, Yuting; Zeng, Jing; Song, Runxia

    2017-12-07

    When space (time) translation symmetry is spontaneously broken, the space crystal (time crystal) forms; when permittivity and permeability periodically vary with space (time), the photonic crystal (photonic time crystal) forms. We proposed the concept of photonic time crystal and rewritten the Maxwell's equations. Utilizing Finite Difference Time Domain (FDTD) method, we simulated electromagnetic wave propagation in photonic time crystal and photonic space-time crystal, the simulation results show that more intensive scatter fields can obtained in photonic time crystal and photonic space-time crystal.

  10. An algorithm based on OmniView technology to reconstruct sagittal and coronal planes of the fetal brain from volume datasets acquired by three-dimensional ultrasound.

    Science.gov (United States)

    Rizzo, G; Capponi, A; Pietrolucci, M E; Capece, A; Aiello, E; Mammarella, S; Arduini, D

    2011-08-01

    To describe a novel algorithm, based on the new display technology 'OmniView', developed to visualize diagnostic sagittal and coronal planes of the fetal brain from volumes obtained by three-dimensional (3D) ultrasonography. We developed an algorithm to image standard neurosonographic planes by drawing dissecting lines through the axial transventricular view of 3D volume datasets acquired transabdominally. The algorithm was tested on 106 normal fetuses at 18-24 weeks of gestation and the visualization rates of brain diagnostic planes were evaluated by two independent reviewers. The algorithm was also applied to nine cases with proven brain defects. The two reviewers, using the algorithm on normal fetuses, found satisfactory images with visualization rates ranging between 71.7% and 96.2% for sagittal planes and between 76.4% and 90.6% for coronal planes. The agreement rate between the two reviewers, as expressed by Cohen's kappa coefficient, was > 0.93 for sagittal planes and > 0.89 for coronal planes. All nine abnormal volumes were identified by a single observer from among a series including normal brains, and eight of these nine cases were diagnosed correctly. This novel algorithm can be used to visualize standard sagittal and coronal planes in the fetal brain. This approach may simplify the examination of the fetal brain and reduce dependency of success on operator skill. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  11. Reliability of the Radiographic Sagittal and Frontal Tibiotalar Alignment after Ankle Arthrodesis.

    Science.gov (United States)

    Willegger, Madeleine; Holinka, Johannes; Nemecek, Elena; Bock, Peter; Wanivenhaus, Axel Hugo; Windhager, Reinhard; Schuh, Reinhard

    2016-01-01

    Accurate measurement of the tibiotalar alignment is important in radiographic outcome assessment of ankle arthrodesis (AA). In studies, various radiological methods have been used to measure the tibiotalar alignment leading to facultative misinterpretation of results. However, to our knowledge, no previous study has investigated the reliability of tibiotalar alignment measurement in AA. We aimed to investigate the reliability of four different methods of measurement of the frontal and sagittal tibiotalar alignment after AA, and to further clarify the most reliable method for determining the longitudinal axis of the tibia. Thirty-eight weight bearing anterior to posterior and lateral ankle radiographs of thirty-seven patients who had undergone AA with a two screw fixation technique were selected. Three observers measured the frontal tibiotalar angle (FTTA) and the sagittal tibiotalar angle (STTA) using four different methods. The methods differed by the definition of the longitudinal tibial axis. Method A was defined by a line drawn along the lateral tibial border in anterior to posterior radiographs and along the posterior tibial border in lateral radiographs. Method B was defined by a line connecting two points in the middle of the proximal and the distal tibial shaft. Method C was drawn "freestyle"along the longitudinal axis of the tibia, and method D was defined by a line connecting the center of the tibial articular surface and a point in the middle of the proximal tibial shaft. Intra- and interobserver correlation coefficients (ICC) and repeated measurement ANOVA were calculated to assess measurement reliability and accuracy. All four methods showed excellent inter- and intraobserver reliability for the FTTA and the STTA. When the longitudinal tibial axis is defined by connecting two points in the middle of the proximal and the distal tibial shaft, the highest interobserver reliability for the FTTA (ICC: 0.980; CI 95%: 0.966-0.989) and for the STTA (ICC: 0

  12. Reliability of the Radiographic Sagittal and Frontal Tibiotalar Alignment after Ankle Arthrodesis.

    Directory of Open Access Journals (Sweden)

    Madeleine Willegger

    Full Text Available Accurate measurement of the tibiotalar alignment is important in radiographic outcome assessment of ankle arthrodesis (AA. In studies, various radiological methods have been used to measure the tibiotalar alignment leading to facultative misinterpretation of results. However, to our knowledge, no previous study has investigated the reliability of tibiotalar alignment measurement in AA. We aimed to investigate the reliability of four different methods of measurement of the frontal and sagittal tibiotalar alignment after AA, and to further clarify the most reliable method for determining the longitudinal axis of the tibia.Thirty-eight weight bearing anterior to posterior and lateral ankle radiographs of thirty-seven patients who had undergone AA with a two screw fixation technique were selected. Three observers measured the frontal tibiotalar angle (FTTA and the sagittal tibiotalar angle (STTA using four different methods. The methods differed by the definition of the longitudinal tibial axis. Method A was defined by a line drawn along the lateral tibial border in anterior to posterior radiographs and along the posterior tibial border in lateral radiographs. Method B was defined by a line connecting two points in the middle of the proximal and the distal tibial shaft. Method C was drawn "freestyle"along the longitudinal axis of the tibia, and method D was defined by a line connecting the center of the tibial articular surface and a point in the middle of the proximal tibial shaft. Intra- and interobserver correlation coefficients (ICC and repeated measurement ANOVA were calculated to assess measurement reliability and accuracy.All four methods showed excellent inter- and intraobserver reliability for the FTTA and the STTA. When the longitudinal tibial axis is defined by connecting two points in the middle of the proximal and the distal tibial shaft, the highest interobserver reliability for the FTTA (ICC: 0.980; CI 95%: 0.966-0.989 and for the

  13. Search for BSM physics in final states with leptons and photons at CMS

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    Numerous new physics models predict the existence of heavy resonances decaying to leptons and photons. This talk presents searches for physics beyond the standard model in final states with leptons and photons at CMS, focusing on the recent results obtained using data collected during the 2015 run of the LHC

  14. Chronic low back pain after lumbosacral fracture due to sagittal and frontal vertebral imbalance.

    Science.gov (United States)

    Boyoud-Garnier, L; Boudissa, M; Ruatti, S; Kerschbaumer, G; Grobost, P; Tonetti, J

    2017-06-01

    Over time, some patients with unilateral or bilateral lumbosacral injuries experience chronic low back pain. We studied the sagittal and frontal balance in a population with these injuries to determine whether mismatch in the pelvic and lumbar angles are associated with chronic low back pain. Patients with posterior pelvic ring fractures (Tile C1, C2, C3 and A3.3) that had healed were included. Foreign patients and those with an associated spinal or acetabular fracture or nonunion were excluded. The review consisted of subjective questionnaires, a clinical examination, and standing A/P and lateral stereoradiographic views. The pelvic tilt (PT), sacral slope (SS), pelvic incidence (PI), measured lumbar lordosis (LLm), T9 sagittal offset, leg discrepancy (LD) and lateral curvature (LC). The expected lumbar lordosis (LLe) was calculated using the formula LLe=PI+9°. We defined lumbopelvic mismatch (LPM) as the difference between LLm and LLe being equal or greater than 25% of LLe. Fifteen patients were reviewed after an average follow-up of 8.8 years [5.4-15]. There were four Tile C1, five Tile C2, five Tile C3 and one Tile A3.3 fracture. Ten of the 15 patients had low back pain. The mean angles were: LLm 49.6° and LLe 71.9° (P=0.002), PT 21.3°, SS 44.1°, PI 62.9° in patients with low back pain and LLm 57.4° and LLe 63.2° (P=0.55), PT 13°, SS 43.1°, PI 54.2° in those without. LPM was present in 9 patients, 8 of who had low back pain (P=0.02). Six patients, all of whom had low back pain, had a mean LC of 7.5° [4.5-23] (P=0.02). The mean LD was 0.77cm. The findings of this small study suggest that patients who experience low back pain after their posterior arch of the pelvic ring fracture has healed, have a lumbopelvic mismatch. Early treatment of these patients should aim to reestablish the anatomy of the pelvic base relative to the frontal and sagittal balance. IV. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Single-photon detector operating under extremely high background photon flux conditions

    International Nuclear Information System (INIS)

    Prochazka, Ivan; Sopko, Bruno; Blazej, Josef

    2009-01-01

    We are reporting our results in research and development in the field of avalanche semiconductor single-photon detectors and their application. Our goal was a development of a solid-state photon-counting detector capable of high-precision photon arrival time tagging in extremely harsh operating conditions. The background photon flux exceeding 10 9 photons per second hitting the detector active area should not avoid the useful signal detection and recognition on the signal level of units of photons per second. This is background photon flux about two orders of magnitude higher than what the conventional solid-state photon counters accept. The detection timing resolution should be better than 100 ps and the delay stability should be on picosecond level. We have developed and tested the active quenched and gated avalanche structure on silicon providing the required features in connection with the K14 detection chips. The detector is capable of gated operation under the conditions of background photon flux of 5x10 9 photons per second. The operational detector tolerates long term exposures to the input photon flux exceeding 10 15 photons (>1 mW) per second without damage.

  16. Normal values of the sagittal diameter of the lumbar spine (vertebral body and dural sac) in children measured by MRI

    International Nuclear Information System (INIS)

    Knirsch, Walter; Kurtz, Claudia; Langer, Mathias; Haeffner, Nicole; Kececioglu, Deniz

    2005-01-01

    The definition of normal values is a prerequisite for the reliable evaluation of abnormality in the lumbar spine, such as spinal canal stenosis or dural ectasia in patients with Marfan syndrome. Values for vertebral body diameter (VBD) and dural sac diameter (DSD) for the lumbar spine have been published in adults. In children, normal values have been established using conventional radiography or myelography, but not by MRI. To define normal values for the sagittal diameter of the vertebral body and dural sac, and to calculate a dural sac ratio (DSR) in the lumbosacral spine (L1-S1) in healthy children using MRI. A total of 75 healthy children between 6 years and 17 years of age were examined using a sagittal T2-weighted sequence. Sagittal VBD and DSD were measured and a DSR was calculated. This was a retrospective and cross-sectional study. With increasing age there is a significant increase of VBD, a slight increase of DSD, and a slight decrease of DSR. There is no significant sex difference. DSR in healthy children is higher than in healthy adults. MRI is a reliable method demonstrating the natural shape of the lumbosacral spine and its absolute values. These normal values compare well with those established by conventional radiological techniques. Our data may serve as a reference for defining dural ectasia in children with Marfan syndrome. (orig.)

  17. Normal values of the sagittal diameter of the lumbar spine (vertebral body and dural sac) in children measured by MRI

    Energy Technology Data Exchange (ETDEWEB)

    Knirsch, Walter [University Children' s Hospital Freiburg, Department of Pediatric Cardiology, Freiburg (Germany); University Children' s Hospital Zurich, Division of Paediatric Cardiology, Zurich (Switzerland); Kurtz, Claudia; Langer, Mathias [University Hospital Freiburg, Department of Radiology, Freiburg (Germany); Haeffner, Nicole; Kececioglu, Deniz [University Children' s Hospital Freiburg, Department of Pediatric Cardiology, Freiburg (Germany)

    2005-04-01

    The definition of normal values is a prerequisite for the reliable evaluation of abnormality in the lumbar spine, such as spinal canal stenosis or dural ectasia in patients with Marfan syndrome. Values for vertebral body diameter (VBD) and dural sac diameter (DSD) for the lumbar spine have been published in adults. In children, normal values have been established using conventional radiography or myelography, but not by MRI. To define normal values for the sagittal diameter of the vertebral body and dural sac, and to calculate a dural sac ratio (DSR) in the lumbosacral spine (L1-S1) in healthy children using MRI. A total of 75 healthy children between 6 years and 17 years of age were examined using a sagittal T2-weighted sequence. Sagittal VBD and DSD were measured and a DSR was calculated. This was a retrospective and cross-sectional study. With increasing age there is a significant increase of VBD, a slight increase of DSD, and a slight decrease of DSR. There is no significant sex difference. DSR in healthy children is higher than in healthy adults. MRI is a reliable method demonstrating the natural shape of the lumbosacral spine and its absolute values. These normal values compare well with those established by conventional radiological techniques. Our data may serve as a reference for defining dural ectasia in children with Marfan syndrome. (orig.)

  18. Photon statistical properties of photon-added two-mode squeezed coherent states

    International Nuclear Information System (INIS)

    Xu Xue-Fen; Wang Shuai; Tang Bin

    2014-01-01

    We investigate photon statistical properties of the multiple-photon-added two-mode squeezed coherent states (PA-TMSCS). We find that the photon statistical properties are sensitive to the compound phase involved in the TMSCS. Our numerical analyses show that the photon addition can enhance the cross-correlation and anti-bunching effects of the PA-TMSCS. Compared with that of the TMSCS, the photon number distribution of the PA-TMSCS is modulated by a factor that is a monotonically increasing function of the numbers of adding photons to each mode; further, that the photon addition essentially shifts the photon number distribution. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  19. Resonance formation in photon-photon collisions

    International Nuclear Information System (INIS)

    Gidal, G.

    1988-08-01

    Recent experimental progress on resonance formation in photon-photon collisions is reviewed with particular emphasis on the pseudoscalar and tensor nonents and on the γγ* production of spin-one resonances. 37 refs., 17 figs., 5 tabs

  20. Physics of quantum light emitters in disordered photonic nanostructures

    International Nuclear Information System (INIS)

    Garcia, P.D.; Lodahl, P.

    2017-01-01

    Nanophotonics focuses on the control of light and the interaction with matter by the aid of intricate nanostructures. Typically, a photonic nanostructure is carefully designed for a specific application and any imperfections may reduce its performance, i.e., a thorough investigation of the role of unavoidable fabrication imperfections is essential for any application. However, another approach to nanophotonic applications exists where fabrication disorder is used to induce functionalities by enhancing light-matter interaction. Disorder leads to multiple scattering of light, which is the realm of statistical optics where light propagation requires a statistical description. We review here the recent progress on disordered photonic nanostructures and the potential implications for quantum photonics devices. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Physics of quantum light emitters in disordered photonic nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, P.D. [Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology, Barcelona (Spain); Lodahl, P. [Niels Bohr Institute, University of Copenhagen (Denmark)

    2017-08-15

    Nanophotonics focuses on the control of light and the interaction with matter by the aid of intricate nanostructures. Typically, a photonic nanostructure is carefully designed for a specific application and any imperfections may reduce its performance, i.e., a thorough investigation of the role of unavoidable fabrication imperfections is essential for any application. However, another approach to nanophotonic applications exists where fabrication disorder is used to induce functionalities by enhancing light-matter interaction. Disorder leads to multiple scattering of light, which is the realm of statistical optics where light propagation requires a statistical description. We review here the recent progress on disordered photonic nanostructures and the potential implications for quantum photonics devices. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. Photonic network R and D activities in Japan

    Science.gov (United States)

    Kitayama, Ken-ichi; Miki, Tetsuya; Morioka, Toshio; Tsushima, Hideaki; Koga, Masafumi; Mori, Kazuyuki; Araki, Soichiro; Sato, Ken-ichi; Onaka, Hiroshi; Namiki, Shu; Aovama, Tomonori

    2005-11-01

    R and D activities on photonic networks in Japan are presented. First, milestones in current, ongoing R and D programs supported by Japanese government agencies are introduced, including long-distance and WDM fiber transmission, wavelength routing, optical burst switching, and control plane technology for IP backbone networks. Their goal was set to evolve a legacy telecommunications network to IP over WDM networks by introducing technologies for WDM and wavelength routing. We then discuss the perspectives of so-called PHASE II R and D programs for photonic networks over the next five years until 2010, by focusing on the report which has been recently issued by the Photonic Internet Forum (PIF), a consortium that has major carriers, telecom vendors, and Japanese academics as members. The PHASE II R and D programs should serve to establish a photonic platform to provide abundant bandwidth on demand, at any time on a real-time basis through the customer's initiative, to promote bandwidth-rich applications, such as grid computing, real-time digital-cinema streaming, medical and educational applications, and network storage in e-commerce.

  3. Papilledema secondary to a superior sagittal sinus thrombosis. Mantle cell lymphoma paraneoplastic syndrome.

    Science.gov (United States)

    Platas-Moreno, I; Antón-Benito, A; Pérez-Cid-Rebolleda, M T; Rosado Sierra, M B

    2016-01-01

    A 46 year old patient presented with visual loss in the left eye during the previous months. Ophthalmoscopic examination and magnetic resonance angiography found the presence of papilledema due to thrombosis in superior sagittal sinus. The examination findings revealed a mantle cell lymphoma. Cerebral venous thrombosis is an unusual cause of papilledema. This type of thrombosis may be secondary to hyper-viscosity within a context of a paraneoplastic syndrome. Copyright © 2015 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  4. Photon-hadron and photon-photon collisions in CMS (including data from p-p, p-A and A-A collisions)

    CERN Document Server

    Rebello Teles, Patricia

    2015-01-01

    Photon-nucleus and photon-photon collisions are abundantly produced at the LHC. The LHC provides a unique opportunity to study high-energy photon-photon interactions, thanks to its high energy and large integrated luminosity. In this talk two CMS analyses concerning photon-hadron and photon-photon collisions are going to be presented. The first deals with the measurement of the coherent $J/\\Psi$ photoproduction cross section in ultra-peripheral PbPb collisions at $\\sqrt{s_{NN}}$ = 2.76 TeV in conjunction with forward neutrons. The second one shows the evidence of the exclusive $\\gamma \\gamma \\to W^{+}W^{-}$ production and improvement on constraints for the anomalous gauge quartic coupling $\\gamma \\gamma WW$ parameters.

  5. Focus on integrated quantum optics

    International Nuclear Information System (INIS)

    O'Brien, Jeremy; Patton, Brian; Sasaki, Masahide; Vučković, Jelena

    2013-01-01

    A key goal of research into quantum information processing is the development of technologies that are scaleable in complexity while allowing the mass manufacture of devices that promise transformative effects on information science. The demonstration that integrated photonics circuits could be made to perform operations that exploit the quantum nature of the photon has turned them into leading candidates for practical quantum information processing technologies. To fully achieve their promise, however, requires research from diverse fields. This focus issue provides a snapshot of some of the areas in which key advances have been made. We are grateful for the contributions from leading teams based around the globe and hope that the degree of progress being made in a challenging and exciting field is apparent from the papers published here. (editorial)

  6. FY 2005 Infrared Photonics Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Anheier, Norman C.; Allen, Paul J.; Ho, Nicolas; Krishnaswami, Kannan; Johnson, Bradley R.; Sundaram, S. K.; Riley, Bradley M.; Martinez, James E.; Qiao, Hong (Amy); Schultz, John F.

    2005-12-01

    Research done by the Infrared Photonics team at Pacific Northwest National Laboratory (PNNL) is focused on developing miniaturized integrated optics for mid-wave infrared (MWIR) and long-wave infrared (LWIR) sensing applications by exploiting the unique optical and material properties of chalcogenide glass. PNNL has developed thin-film deposition capabilities, direct laser writing techniques, infrared photonic device demonstration, holographic optical element design and fabrication, photonic device modeling, and advanced optical metrology—all specific to chalcogenide glass. Chalcogenide infrared photonics provides a pathway to quantum cascade laser (QCL) transmitter miniaturization. QCLs provide a viable infrared laser source for a new class of laser transmitters capable of meeting the performance requirements for a variety of national security sensing applications. The high output power, small size, and superb stability and modulation characteristics of QCLs make them amenable for integration as transmitters into ultra-sensitive, ultra-selective point sampling and remote short-range chemical sensors that are particularly useful for nuclear nonproliferation missions. During FY 2005, PNNL’s Infrared Photonics research team made measurable progress exploiting the extraordinary optical and material properties of chalcogenide glass to develop miniaturized integrated optics for mid-wave infrared (MWIR) and long-wave infrared (LWIR) sensing applications. We investigated sulfur purification methods that will eventually lead to routine production of optical quality chalcogenide glass. We also discovered a glass degradation phenomenon and our investigation uncovered the underlying surface chemistry mechanism and developed mitigation actions. Key research was performed to understand and control the photomodification properties. This research was then used to demonstrate several essential infrared photonic devices, including LWIR single-mode waveguide devices and

  7. Assessment of Normal Sagittal Alignment of the Spine and Pelvis in Children and Adolescents

    Directory of Open Access Journals (Sweden)

    Hasan Ghandhari

    2013-01-01

    Full Text Available Aim. We aimed to determine spinopelvic balance in 8–19-year-old-people in order to assess pelvic and spinal parameters in sagittal view. Methods. Ninety-eight healthy students aged 8–19 years, who lived in the central parts of Tehran, were assessed. Demographic data, history of present and past diseases, height (cm, and weight (kg were collected. Each subject was examined by an orthopedic surgeon and spinal radiographs in lateral view were obtained. Eight spinopelvic parameters were measured by 2 orthopedic spine surgeons. Results. Ninety-eight subjects, among which 48 were girls (49% and 50 boys (51%, with a mean age of 13.6±2.9 years (range: 8–19 were evaluated. Mean height and weight of children were 153.6±15.6 cm and 49.9±13.1 kgs, respectively. Mean TK, LL, TT, LT, and PI of subjects were 37.1 ± 9.9°, 39.6 ± 12.4°, 7.08 ± 4.9°, 12.0 ± 5.9°, and 45.37 ± 10.7°, respectively. Conclusion. Preoperation planning for spinal fusion surgeries via applying PI seems reasonable. Predicating “abnormal” to lordosis and kyphosis values alone without considering overall sagittal balance is incorrect. Mean of SS and TK in our population is slightly less than that in Caucasians.

  8. Perspectives: Nanofibers and nanowires for disordered photonics

    Directory of Open Access Journals (Sweden)

    Dario Pisignano

    2017-03-01

    Full Text Available As building blocks of microscopically non-homogeneous materials, semiconductor nanowires and polymer nanofibers are emerging component materials for disordered photonics, with unique properties of light emission and scattering. Effects found in assemblies of nanowires and nanofibers include broadband reflection, significant localization of light, strong and collective multiple scattering, enhanced absorption of incident photons, synergistic effects with plasmonic particles, and random lasing. We highlight recent related discoveries, with a focus on material aspects. The control of spatial correlations in complex assemblies during deposition, the coupling of modes with efficient transmission channels provided by nanofiber waveguides, and the embedment of random architectures into individually coded nanowires will allow the potential of these photonic materials to be fully exploited, unconventional physics to be highlighted, and next-generation optical devices to be achieved. The prospects opened by this technology include enhanced random lasing and mode-locking, multi-directionally guided coupling to sensors and receivers, and low-cost encrypting miniatures for encoders and labels.

  9. Magnetic resonance imaging of skeletal muscle in patients with Duchenne muscular dystrophy; Serial axial and sagittal section studies

    Energy Technology Data Exchange (ETDEWEB)

    Nagao, Hideo (Ehime Univ., Matsuyama (Japan). Faculty of Education); Morimoto, Takehiko; Sano, Nozomi; Takahashi, Mitsugi; Nagai, Hironao; Tawa, Ritsuko; Yoshimatsu, Makoto; Woo Young-Jong; Matsuda, Hiroshi

    1991-01-01

    Magnetic resonance imaging of skeletal muscles in thirteen patients with Duchenne muscular dystrophy was performed to estimate pathological changes. Serial axial and sagittal sections of the right lower extremity were recorded. In the early stage, the T{sub 1} values of gastrocnemius and soleus muscles were slightly lower than the control values, and in the late stage, the values were much lower in all muscles examined. In sagittal sections, the gastrocnemius muscle in the early stage showed a high density area at the distal region adjacent to soleus muscle, and the soleus muscle showed a high density area adjacent to the gestrocnemius muscle. In serial axial sections, high density areas of the anterior and posterior tibialis muscles appeared first at their proximal and peripheral regions. It was concluded that the sequence of appearance of pathological changes was different not only among individual muscles but also among various regions of each muscle; the high density changes appeared first at myotendon junctions. (author).

  10. Study of prompt photon and neutral pion production in photon-photon scattering with the OPAL experiment

    CERN Document Server

    Lillich, Joachim

    2003-01-01

    For the first time at LEP the production of prompt photons is studied in the collisions of quasi-real photons using the OPAL data taken at e+e- centre-of mass energies between 183 GeV and 209 GeV. The total inclusive production cross-section for isolated prompt photons in the kinematic range of transverse momentum > 3.0 GeV and the absolut value of pseudorapidity <1 is determined to be (0.32 +- 0.04 (stat) +- 0.04 (sys)) pb. Differential cross-sections are compared to the predictions of a next-to-leading-order (NLO) calculation. In the second part of this thesis inclusive differential neutral pion cross-sections in photon photon collisons are measured. This measurement is an important test of QCD. In addition this process is the main background for prompt photons.

  11. Polarization control of multi-photon absorption under intermediate femtosecond laser field

    International Nuclear Information System (INIS)

    Cheng Wenjing; Liang Guo; Wu Ping; Liu Pei; Jia Tianqing; Sun Zhenrong; Zhang Shian

    2017-01-01

    It has been shown that the femtosecond laser polarization modulation is a very simple and well-established method to control the multi-photon absorption process by the light–matter interaction. Previous studies mainly focused on the multi-photon absorption control in the weak field. In this paper, we further explore the polarization control behavior of multi-photon absorption process in the intermediate femtosecond laser field. In the weak femtosecond laser field, the second-order perturbation theory can well describe the non-resonant two-photon absorption process. However, the higher order nonlinear effect (e.g., four-photon absorption) can occur in the intermediate femtosecond laser field, and thus it is necessary to establish new theoretical model to describe the multi-photon absorption process, which includes the two-photon and four-photon transitions. Here, we construct a fourth-order perturbation theory to study the polarization control behavior of this multi-photon absorption under the intermediate femtosecond laser field excitation, and our theoretical results show that the two-photon and four-photon excitation pathways can induce a coherent interference, while the coherent interference is constructive or destructive that depends on the femtosecond laser center frequency. Moreover, the two-photon and four-photon transitions have the different polarization control efficiency, and the four-photon absorption can obtain the higher polarization control efficiency. Thus, the polarization control efficiency of the whole excitation process can be increased or decreased by properly designing the femtosecond laser field intensity and laser center frequency. These studies can provide a clear physical picture for understanding and controlling the multi-photon absorption process in the intermediate femtosecond laser field, and also can provide a theoretical guidance for the future experimental realization. (paper)

  12. Classical reconstruction of interference patterns of position-wave-vector-entangled photon pairs by the time-reversal method

    Science.gov (United States)

    Ogawa, Kazuhisa; Kobayashi, Hirokazu; Tomita, Akihisa

    2018-02-01

    The quantum interference of entangled photons forms a key phenomenon underlying various quantum-optical technologies. It is known that the quantum interference patterns of entangled photon pairs can be reconstructed classically by the time-reversal method; however, the time-reversal method has been applied only to time-frequency-entangled two-photon systems in previous experiments. Here, we apply the time-reversal method to the position-wave-vector-entangled two-photon systems: the two-photon Young interferometer and the two-photon beam focusing system. We experimentally demonstrate that the time-reversed systems classically reconstruct the same interference patterns as the position-wave-vector-entangled two-photon systems.

  13. PHOTON09. Proceedings of the international conference on the structure and interactions of the photon including the 18th international workshop on photon-photon collisions and the international workshop on high energy photon linear colliders

    International Nuclear Information System (INIS)

    Behnke, Olaf; Diehl, Markus; Schoerner-Sadenius, Thomas; Steinbrueck, Georg

    2010-01-01

    The following topics were dealt with: Electroweak and new physics, photon-collider technology, low-energy photon experiments, prompt photons, photon structure, jets and heavy flavours, vacuum polarization and light-by-light scattering, small-x processes, diffraction, total cross sections, exclusive channels and resonances, photons in astroparticle physics. (HSI)

  14. PHOTON09. Proceedings of the international conference on the structure and interactions of the photon including the 18th international workshop on photon-photon collisions and the international workshop on high energy photon linear colliders

    Energy Technology Data Exchange (ETDEWEB)

    Behnke, Olaf; Diehl, Markus; Schoerner-Sadenius, Thomas; Steinbrueck, Georg [eds.

    2010-01-15

    The following topics were dealt with: Electroweak and new physics, photon-collider technology, low-energy photon experiments, prompt photons, photon structure, jets and heavy flavours, vacuum polarization and light-by-light scattering, small-x processes, diffraction, total cross sections, exclusive channels and resonances, photons in astroparticle physics. (HSI)

  15. MHz rate and efficient synchronous heralding of single photons at telecom wavelengths.

    Science.gov (United States)

    Pomarico, Enrico; Sanguinetti, Bruno; Guerreiro, Thiago; Thew, Rob; Zbinden, Hugo

    2012-10-08

    We report on the realization of a synchronous source of heralded single photons at telecom wavelengths with MHz heralding rates and high heralding efficiency. This source is based on the generation of photon pairs at 810 and 1550 nm via Spontaneous Parametric Down Conversion (SPDC) in a 1 cm periodically poled lithium niobate (PPLN) crystal pumped by a 532 nm pulsed laser. As high rates are fundamental for multi-photon experiments, we show that single telecom photons can be announced at 4.4 MHz rate with 45% heralding efficiency. When we focus only on the optimization of the coupling of the heralded photon, the heralding efficiency can be increased up to 80%. Furthermore, we experimentally observe that group velocity mismatch inside long crystals pumped in a pulsed mode affects the spectrum of the emitted photons and their fibre coupling efficiency. The length of the crystal in this source has been chosen as a trade off between high brightness and high coupling efficiency.

  16. Coupling of a single active nanoparticle to a polymer-based photonic structure

    Directory of Open Access Journals (Sweden)

    Dam Thuy Trang Nguyen

    2016-03-01

    Full Text Available The engineered coupling between a guest moiety (molecule, nanoparticle and the host photonic nanostructure may provide a great enhancement of the guest optical response, leading to many attractive applications. In this article, we describe briefly the basic concept and some recent progress considering the coupling of a single nanoparticle into a photonic structure. Different kinds of nanoparticles of great interest including quantum dots and nitrogen-vacancy centers in nanodiamond for single photon source, nonlinear nanoparticles for efficient nonlinear effect and sensors, magnetic nanoparticles for Kerr magneto-optical effect, and plasmonic nanoparticles for ultrafast optical switching and sensors, are briefly reviewed. We focus further on the coupling of plasmonic gold nanoparticles and polymeric photonic structures by optimizing theoretically the photonic structures and developing efficient way to realize desired hybrid structures. The simple and low-cost fabrication technique, the optical enhancement of the fluorescent nanoparticles induced by the photonic structure, as well as the limitations, challenges and appealing prospects are discussed in details.

  17. Self-regulated transport in photonic crystals with phase-changing defects

    Science.gov (United States)

    Thomas, Roney; Ellis, Fred M.; Vitebskiy, Ilya; Kottos, Tsampikos

    2018-01-01

    Phase-changing materials (PCMs) are widely used for optical data recording, sensing, all-optical switching, and optical limiting. Our focus here is on the case when the change in transmission characteristics of the optical material is caused by the input light itself. Specifically, the light-induced heating triggers the phase transition in the PCM. In this paper, using a numerical example, we demonstrate that the incorporation of the PCM in a photonic structure can lead to a dramatic modification of the effects of light-induced phase transition, as compared to a stand-alone sample of the same PCM. Our focus is on short pulses. We discuss some possible applications of such phase-changing photonic structures for optical sensing and limiting.

  18. Preoperative cervical sagittal alignment parameters and their impacts on myelopathy in patients with cervical spondylotic myelopathy: a retrospective study

    Directory of Open Access Journals (Sweden)

    Wei Yuan

    2017-11-01

    Full Text Available Background Cervical sagittal alignment plays an important role in the pathogenesis of cervical spondylotic myelopathy (CSM, but there are limited studies on the cervical sagittal parameters in CSM patients and their correlations with myelopathy. The aim of this study is to investigate the correlations among the preoperative cervical sagittal alignment parameters and their correlations with the development of myelopathy in patients with CSM. Methods We retrospectively collected 212 patients with CSM who underwent surgical interventions. Gender, age, modified Japanese Orthopedic Association score (mJOA, cervical lordosis (CL, C2–C7 sagittal vertical axis (C2–C7 SVA, T1 slope (T1S, neck tilt (NT and thoracic inlet angle (TIA were collected before operation. Interobserver and intraobserver reliability were calculated for all measurements (intraclass correlation coefficient, ICC. Data were analyzed with Pearson and Spearman correlation tests and multiple linear regression analysis. Results A total of 212 patients with CSM were included in this study (male: 136, female: 76 with an average age of 54.5 ± 10.1 years old. Intraobserver and interobserver reliability for all included radiographic parameters presented good to excellent agreement (ICC > 0.7. No significant differences in demographic and radiological parameters have been observed between males and females (P > 0.05. We found statistically significant correlations among the following parameters: age with CL (r = 0.135, P = 0.049, age with T1S (r = 0.222, P = 0.001, CL with T1S (r = 0.291, P < 0.001, CL with C2-C7 SVA (r =  − 0.395, P < 0.001, mJOA with age (r =  − 0.274, P < 0.001, mJOA with C2–C7 SVA (r =  − 0.219, P < 0.001 and mJOA with T1S(r =  − 0.171, p = 0.013. Linear regression analysis showed that C2–C7 SVA was the predictor of CL (adjusted R2 = 0.152, P < 0.001 and multiple linear regression showed that age combined with C

  19. Resonant Photonic States in Coupled Heterostructure Photonic Crystal Waveguides

    Directory of Open Access Journals (Sweden)

    Sabarinathan J

    2010-01-01

    Full Text Available Abstract In this paper, we study the photonic resonance states and transmission spectra of coupled waveguides made from heterostructure photonic crystals. We consider photonic crystal waveguides made from three photonic crystals A, B and C, where the waveguide heterostructure is denoted as B/A/C/A/B. Due to the band structure engineering, light is confined within crystal A, which thus act as waveguides. Here, photonic crystal C is taken as a nonlinear photonic crystal, which has a band gap that may be modified by applying a pump laser. We have found that the number of bound states within the waveguides depends on the width and well depth of photonic crystal A. It has also been found that when both waveguides are far away from each other, the energies of bound photons in each of the waveguides are degenerate. However, when they are brought close to each other, the degeneracy of the bound states is removed due to the coupling between them, which causes these states to split into pairs. We have also investigated the effect of the pump field on photonic crystal C. We have shown that by applying a pump field, the system may be switched between a double waveguide to a single waveguide, which effectively turns on or off the coupling between degenerate states. This reveals interesting results that can be applied to develop new types of nanophotonic devices such as nano-switches and nano-transistors.

  20. Meso-optical Fourier transform microscope with double focusing

    International Nuclear Information System (INIS)

    Batusov, Yu.A.; Soroko, L.M.; Tereshchenko, V.V.

    1992-01-01

    The meso-optical Fourier transform microscope (MFTM) with double focusing for particle tracks of low ionization level in the nuclear emulsion is described. It is shown experimentally that this device enables one to get high concentration of information about the position of the particle track in the nuclear emulsion and thus to increase the signal-to-noise ratio. It is shown that spreading of the meso-optical image of the particle track in the sagittal section of the MFTM can be eliminated completely in the frame of the diffraction limit. The number of the additional degrees of freedom in this new MFTM system along depth coordinate is equal to 20 in comparison to single degree of freedom in the Fourier transform microscope of the direct observation. 10 refs.; 15 figs

  1. Normal development of brainstem in childhood. Measurement of the area on mid-sagittal MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kutomi, Kimiko [Teikyo Univ., Tokyo (Japan). Faculty of Medicine

    2005-05-01

    Developmental abnormality of brainstem is shown in pediatric patients with mental retardation, autism, periventricular leukomalacia, neurodegenerative disease, and so on. Our purpose here is to clarify the normal developmental pattern of the brainstem. We measured the area of tectum, midbrain tegmentum, pons, basis pontis and pontine tegmentum on mid-sagittal MR images in 111 children (newborn to 20 year old). Different growth patterns were shown in all parts of the brainstem. Tectum showed a subtle increase in area from the newborn to adult period, while midbrain tegmentum and pontine tegmenturn showed a mild and gradual increase in area. Pons and pontine tegmentum showed a rapid and prominent increase in area from newborn to infant period and gradual increase in area until the adult period. These different growth patterns seemed to be consistent with differences in the myelination cycles of the neuronal fibers, maturation of the nuclei and proliferation of glial cells in each part of the brainstem. Mid-sagittal MR imaging of the head is accurate and reproducible and is used conveniently in routine head MR study, making it very useful for the diagnosis of many central nervous diseases and anomalies. We believe that this new milestone provided in this study will be helpful in distinguishing normal children from those that have neurodegenerative disorders. (author)

  2. Normal development of brainstem in childhood. Measurement of the area on mid-sagittal MR imaging

    International Nuclear Information System (INIS)

    Kutomi, Kimiko

    2005-01-01

    Developmental abnormality of brainstem is shown in pediatric patients with mental retardation, autism, periventricular leukomalacia, neurodegenerative disease, and so on. Our purpose here is to clarify the normal developmental pattern of the brainstem. We measured the area of tectum, midbrain tegmentum, pons, basis pontis and pontine tegmentum on mid-sagittal MR images in 111 children (newborn to 20 year old). Different growth patterns were shown in all parts of the brainstem. Tectum showed a subtle increase in area from the newborn to adult period, while midbrain tegmentum and pontine tegmenturn showed a mild and gradual increase in area. Pons and pontine tegmentum showed a rapid and prominent increase in area from newborn to infant period and gradual increase in area until the adult period. These different growth patterns seemed to be consistent with differences in the myelination cycles of the neuronal fibers, maturation of the nuclei and proliferation of glial cells in each part of the brainstem. Mid-sagittal MR imaging of the head is accurate and reproducible and is used conveniently in routine head MR study, making it very useful for the diagnosis of many central nervous diseases and anomalies. We believe that this new milestone provided in this study will be helpful in distinguishing normal children from those that have neurodegenerative disorders. (author)

  3. Demonstrating optical aberrations in the laboratory

    CSIR Research Space (South Africa)

    Naidoo, Darryl

    2009-07-01

    Full Text Available THE TANGENTIAL AND SAGITTAL FOCI DO NOT COINCIDE AND THE SYSTEM APPEARS TO HAVE 2 POINTS OF FOCUS SAGITTAL PLANE TANGENTIAL PLANE TANGENTIAL IMAGE OPTICAL AXIS OBJECT POINT SAGITTAL IMAGE ASTIGMATISM © CSIR 2008 www....csir.co.za ASTIGMATISM ARISES WHEN THE TANGENTIAL AND SAGITTAL FOCI DO NOT COINCIDE AND THE SYSTEM APPEARS TO HAVE 2 POINTS OF FOCUS SAGITTAL PLANE TANGENTIAL PLANE TANGENTIAL IMAGE OPTICAL AXIS OBJECT POINT SAGITTAL IMAGE FOCAL PLANE COMA IMAGE A B θ COMA...

  4. Ultrafast-laser-inscribed 3D integrated photonics: challenges and emerging applications

    Directory of Open Access Journals (Sweden)

    Gross S.

    2015-11-01

    Full Text Available Since the discovery that tightly focused femtosecond laser pulses can induce a highly localised and permanent refractive index modification in a large number of transparent dielectrics, the technique of ultrafast laser inscription has received great attention from a wide range of applications. In particular, the capability to create three-dimensional optical waveguide circuits has opened up new opportunities for integrated photonics that would not have been possible with traditional planar fabrication techniques because it enables full access to the many degrees of freedom in a photon. This paper reviews the basic techniques and technological challenges of 3D integrated photonics fabricated using ultrafast laser inscription as well as reviews the most recent progress in the fields of astrophotonics, optical communication, quantum photonics, emulation of quantum systems, optofluidics and sensing.

  5. A clinico-radiographic study to compare and co-relate sagittal condylar guidance determined by intraoral gothic arch tracing method and panoramic radiograph in completely edentulous patients.

    Science.gov (United States)

    Shetty, Sanath; Kunta, Mythili; Shenoy, Kamalakanth

    2018-01-01

    The purpose of this study was to compare and correlate sagittal condylar guidance determined by intraoral gothic arch tracing method and panoramic radiograph in edentulous patients. Twelve completely edentulous patients were selected by the inclusion and exclusion criteria. Conventional steps in the fabrication of complete denture till jaw relation were carried out. Intraoral gothic arch tracing and protrusive interocclusal records were obtained for each patient. Protrusive interocclusal record was used to program the Hanau Wide-Vue semi-adjustable articulator, thus obtaining the sagittal condylar guidance angle. Using RadiAnt DICOM software, on the orthopantomogram obtained for each patient in the study, two reference lines were drawn. The Frankfort's horizontal plane and the mean curvature line (joining the most superior and the inferior points on the glenoid fossa curvature) were drawn. The mean curvature line was extended to intersect the Frankfort's horizontal plane, thus obtaining the radiographic sagittal condylar guidance angle. The condylar guidance angles obtained by these two methods were compared and subjected to paired t -test. There was no statistically significant difference between the sagittal condylar guidance angles obtained between right and left sides with intraoral gothic arch tracing and radiographic methods ( P = 0.107 and 0.07, respectively). Within the limitations of this study, it was concluded that the protrusive condylar guidance angles obtained by panoramic radiograph may be used for programming semi-adjustable articulators.

  6. Incomplete oblique sagittal fractures of the dorsal cortex of the third metacarpal bone in six horses

    International Nuclear Information System (INIS)

    Watt, B.C.; Foerner, J.J.; Haines, G.R.

    1998-01-01

    To describe incomplete oblique sagittal dorsal cortical fractures of the equine third metacarpal bone, their surgical repair, and subsequent performance of the horses. Retrospective examination of medical records and racing performance. Six Thoroughbred race horses, 2 to 4 years of age. Radiographic confirmation of all fractures preceded general anesthesia and surgical correction. Three fractures were treated by intracortical compression using screws placed in lag fashion, and five fractures were treated by osteostixis. Race records were reviewed for each horse to determine performance after surgery. Fractures were best observed on palmarodorsal radiographic projections. Three horses treated by intracortical compression returned to racing, but fracture recurred in one horse and was treated by osteostixis. This horse and the other three horses treated by osteostixis raced after surgery. Horses with incomplete oblique sagittal fractures of the dorsal cortex of the third metacarpal bone can race after surgical management of the fracture by screws placed in lag fashion or osteostixis. The authors' preferred surgical procedure for managing this fracture is osteostixis. Palmarodorsal radiographic projections of the third metacarpal bone are recommended in young Thoroughbred race horses suspected of having dorsal metacarpal stress fractures

  7. Rapid volumetric imaging with Bessel-Beam three-photon microscopy

    Science.gov (United States)

    Chen, Bingying; Huang, Xiaoshuai; Gou, Dongzhou; Zeng, Jianzhi; Chen, Guoqing; Pang, Meijun; Hu, Yanhui; Zhao, Zhe; Zhang, Yunfeng; Zhou, Zhuan; Wu, Haitao; Cheng, Heping; Zhang, Zhigang; Xu, Chris; Li, Yulong; Chen, Liangyi; Wang, Aimin

    2018-01-01

    Owing to its tissue-penetration ability, multi-photon fluorescence microscopy allows for the high-resolution, non-invasive imaging of deep tissue in vivo; the recently developed three-photon microscopy (3PM) has extended the depth of high-resolution, non-invasive functional imaging of mouse brains to beyond 1.0 mm. However, the low repetition rate of femtosecond lasers that are normally used in 3PM limits the temporal resolution of point-scanning three-photon microscopy. To increase the volumetric imaging speed of 3PM, we propose a combination of an axially elongated needle-like Bessel-beam with three-photon excitation (3PE) to image biological samples with an extended depth of focus. We demonstrate the higher signal-to-background ratio (SBR) of the Bessel-beam 3PM compared to the two-photon version both theoretically and experimentally. Finally, we perform simultaneous calcium imaging of brain regions at different axial locations in live fruit flies and rapid volumetric imaging of neuronal structures in live mouse brains. These results highlight the unique advantage of conducting rapid volumetric imaging with a high SBR in the deep brain in vivo using scanning Bessel-3PM.

  8. Anterior or posterior sagittal anorectoplasty without colostomy for low-type anorectal malformation: how to get a better outcome?

    NARCIS (Netherlands)

    Kuijper, Caroline F.; Aronson, Daniel C.

    2010-01-01

    Background/Purpose: Usually, anorectal malformations (ARM) are treated in 2 or 3 stages for fear of disturbed wound healing and subsequent damage to the anal sphincter complex. The aim of this study was to assess the feasibility, safety, advantages, and follow-up of an anterior or posterior sagittal

  9. Anterior or posterior sagittal anorectoplasty without colostomy for low-type anorectal malformation: how to get a better outcome?

    NARCIS (Netherlands)

    Kuijper, C.F.; Aronson, D.C.

    2010-01-01

    BACKGROUND/PURPOSE: Usually, anorectal malformations (ARM) are treated in 2 or 3 stages for fear of disturbed wound healing and subsequent damage to the anal sphincter complex. The aim of this study was to assess the feasibility, safety, advantages, and follow-up of an anterior or posterior sagittal

  10. Large Aperture "Photon Bucket" Optical Receiver Performance in High Background Environments

    Science.gov (United States)

    Vilnrotter, Victor A.; Hoppe, D.

    2011-01-01

    The potential development of large aperture groundbased "photon bucket" optical receivers for deep space communications, with acceptable performance even when pointing close to the sun, is receiving considerable attention. Sunlight scattered by the atmosphere becomes significant at micron wavelengths when pointing to a few degrees from the sun, even with the narrowest bandwidth optical filters. In addition, high quality optical apertures in the 10-30 meter range are costly and difficult to build with accurate surfaces to ensure narrow fields-of-view (FOV). One approach currently under consideration is to polish the aluminum reflector panels of large 34-meter microwave antennas to high reflectance, and accept the relatively large FOV generated by state-of-the-art polished aluminum panels with rms surface accuracies on the order of a few microns, corresponding to several-hundred micro-radian FOV, hence generating centimeter-diameter focused spots at the Cassegrain focus of 34-meter antennas. Assuming pulse-position modulation (PPM) and Poisson-distributed photon-counting detection, a "polished panel" photon-bucket receiver with large FOV will collect hundreds of background photons per PPM slot, along with comparable signal photons due to its large aperture. It is demonstrated that communications performance in terms of PPM symbol-error probability in high-background high-signal environments depends more strongly on signal than on background photons, implying that large increases in background energy can be compensated by a disproportionally small increase in signal energy. This surprising result suggests that large optical apertures with relatively poor surface quality may nevertheless provide acceptable performance for deep-space optical communications, potentially enabling the construction of cost-effective hybrid RF/optical receivers in the future.

  11. Polychromatic photons

    DEFF Research Database (Denmark)

    Keller, Ole

    2002-01-01

    train quantum electrodynamics. A brief description of particle (photon) position operators is given, and it is shown that photons usually are only algebraically confined in an emission process. Finally, it is demonstrated that the profile of the birth domain of a radio-frequency photon emitted...

  12. Proximity focusing RICH with TOF capabilities

    International Nuclear Information System (INIS)

    Korpar, S.; Adachi, I.; Fujita, K.; Fukushima, T.; Gorisek, A.; Hayashi, D.; Iijima, T.; Ikado, T.; Ishikawa, T.; Kawai, H.; Kozakai, Y.; Krizan, P.; Kuratani, A.; Mazuka, Y.; Nakagawa, T.; Nishida, S.; Ogawa, S.; Pestotnik, R.; Seki, T.; Sumiyoshi, T.; Tabata, M.; Unno, Y.

    2007-01-01

    A proximity focusing RICH counter with a multi-channel micro-channel plate (MCP) PMT was tested as a time-of-flight counter. Cherenkov photons emitted in the radiator medium as well as in the entrance window of the PMT were used for the time-of-flight measurement, and an excellent performance of the counter could be demonstrated

  13. Reproducibility and repeatability of a new computerized software for sagittal spinopelvic and scoliosis curvature radiologic measurements: Keops(®).

    Science.gov (United States)

    Maillot, C; Ferrero, E; Fort, D; Heyberger, C; Le Huec, J-C

    2015-07-01

    The purpose of this study was to evaluate the inter- and intra-observer variability of the computerized radiologic measurements using Keops(®) and to determine the bias between the software and the standard paper measurement. Four individuals measured all frontal and sagittal variables on the 30 X-rays randomly selected on two occasions (test and retest conditions). The Bland-Altman plot was used to determine the degree of agreement between the measurement on paper X-ray and the measurement using Keops(®) for all reviewers and for the two measures; the intraclass correlation coefficient (ICC) was calculated for each pair of analyses to assess interobserver reproducibility among the four reviewers for the same patient using either paper X-ray or Keops(®) measurement and finally, concordance correlation coefficient (rc) was calculated to assess intraobserver repeatability among the same reviewer for one patient between the two measure using the same method (paper or Keops(®)). The mean difference calculated between the two methods was minimal at -0, 4° ± 3.41° [-7.1; 6.4] for frontal measurement and 0.1° ± 3.52° [-6.7; 6.8] for sagittal measurement. Keops(®) has a better interobserver reproducibility than paper measurement for determination of the sagittal pelvic parameter (ICC = 0.9960 vs. 0.9931; p = 0.0001). It has a better intraobserver repeatability than paper for determination of Cobbs angle (rc = 0.9872 vs. 0.9808; p rc = 0.9981 vs. 0.9953; p plane and that the use of this software can be recommended for clinical application. Diagnostic, level III.

  14. Microwave photonics

    CERN Document Server

    Lee, Chi H

    2006-01-01

    Wireless, optical, and electronic networks continue to converge, prompting heavy research into the interface between microwave electronics, ultrafast optics, and photonic technologies. New developments arrive nearly as fast as the photons under investigation, and their commercial impact depends on the ability to stay abreast of new findings, techniques, and technologies. Presenting a broad yet in-depth survey, Microwave Photonics examines the major advances that are affecting new applications in this rapidly expanding field.This book reviews important achievements made in microwave photonics o

  15. Spin polarization in top pair production in association with two photons at NLO+PS

    CERN Document Server

    Luisoni, Gionata

    2018-01-01

    This talk focuses on the impact of top-quark spin polarization effects in Higgs boson production in association with a top-quark pair, where the Higgs boson decays to two photons. Predictions for the signal are compared with direct top-quark pair production in association with two photons at NLO+PS.

  16. Spin polarization in top pair production in association with two photons at NLO+PS

    CERN Document Server

    Luisoni, Gionata

    2017-01-01

    This talk focuses on the impact of top-quark spin polarization effects in Higgs boson production in association with a top-quark pair, where the Higgs boson decays to two photons. Predictions for the signal are compared with direct top-quark pair production in association with two photons at NLO+PS.

  17. Recent developments in the theory of photon-photon collisions

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1984-09-01

    Over the past few years the field of photon-photon collisions has emerged as one of the best testing grounds for QCD, particularly in the area of exclusive and inclusive hard scattering processes, exotic resonance production, and detailed tests of the coupling of real and virtual photons to the quark current. In this summary of contributed papers, I will briefly review recent theoretical progress in the analysis of two-photon reactions and possible directions for future work. 29 references

  18. Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting.

    Science.gov (United States)

    Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay

    2016-04-09

    Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e(-) read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor.

  19. Photon nanojet lens: design, fabrication and characterization

    International Nuclear Information System (INIS)

    Xu, Chen; Zhang, Sichao; Shao, Jinhai; Lu, Bing-Rui; Chen, Yifang; Mehfuz, Reyad; Drakeley, Stacey; Huang, Fumin

    2016-01-01

    In this paper, a novel nanolens with super resolution, based on the photon nanojet effect through dielectric nanostructures in visible wavelengths, is proposed. The nanolens is made from plastic SU-8, consisting of parallel semi-cylinders in an array. This paper focuses on the lens designed by numerical simulation with the finite-difference time domain method and nanofabrication of the lens by grayscale electron beam lithography combined with a casting/bonding/lift-off transfer process. Monte Carlo simulation for injected charge distribution and development modeling was applied to define the resultant 3D profile in PMMA as the template for the lens shape. After the casting/bonding/lift-off process, the fabricated nanolens in SU-8 has the desired lens shape, very close to that of PMMA, indicating that the pattern transfer process developed in this work can be reliably applied not only for the fabrication of the lens but also for other 3D nanopatterns in general. The light distribution through the lens near its surface was initially characterized by a scanning near-field optical microscope, showing a well defined focusing image of designed grating lines. Such focusing function supports the great prospects of developing a novel nanolithography based on the photon nanojet effect. (paper)

  20. Manipulation of photons at the surface of three-dimensional photonic crystals.

    Science.gov (United States)

    Ishizaki, Kenji; Noda, Susumu

    2009-07-16

    In three-dimensional (3D) photonic crystals, refractive-index variations with a periodicity comparable to the wavelength of the light passing through the crystal give rise to so-called photonic bandgaps, which are analogous to electronic bandgaps for electrons moving in the periodic electrostatic potential of a material's crystal structure. Such 3D photonic bandgap crystals are envisioned to become fundamental building blocks for the control and manipulation of photons in optical circuits. So far, such schemes have been pursued by embedding artificial defects and light emitters inside the crystals, making use of 3D bandgap directional effects. Here we show experimentally that photons can be controlled and manipulated even at the 'surface' of 3D photonic crystals, where 3D periodicity is terminated, establishing a new and versatile route for photon manipulation. By making use of an evanescent-mode coupling technique, we demonstrate that 3D photonic crystals possess two-dimensional surface states, and we map their band structure. We show that photons can be confined and propagate through these two-dimensional surface states, and we realize their localization at arbitrary surface points by designing artificial surface-defect structures through the formation of a surface-mode gap. Surprisingly, the quality factors of the surface-defect mode are the largest reported for 3D photonic crystal nanocavities (Q up to approximately 9,000). In addition to providing a new approach for photon manipulation by photonic crystals, our findings are relevant for the generation and control of plasmon-polaritons in metals and the related surface photon physics. The absorption-free nature of the 3D photonic crystal surface may enable new sensing applications and provide routes for the realization of efficient light-matter interactions.

  1. Coupling the photon kinetics of soft photons with high energy photons

    Science.gov (United States)

    Silva, L. O.; Bingham, R.

    2017-10-01

    The description of electromagnetic fields based on the generalized photon kinetic theory, which takes advantage of the Wigner-Moyal description for the corresponding classical field theory, is capable of capturing collective plasma dynamics in the relativistic regime driven by broadband incoherent or partially coherent sources. We explore the possibility to extend this description to include the dynamics of hard photons in the plasma, whose interaction is dominated by single scattering processes. Examples of the modification of classical plasma instabilities due to the presence of hard photons is discussed. Work supported by the European Research Council (ERC-AdG-2015 InPairs Grant No. 695088).

  2. Selective two-photon excitation of a vibronic state by correlated photons.

    Science.gov (United States)

    Oka, Hisaki

    2011-03-28

    We theoretically investigate the two-photon excitation of a molecular vibronic state by correlated photons with energy anticorrelation. A Morse oscillator having three sets of vibronic states is used, as an example, to evaluate the selectivity and efficiency of two-photon excitation. We show that a vibrational mode can be selectively excited with high efficiency by the correlated photons, without phase manipulation or pulse-shaping techniques. This can be achieved by controlling the quantum correlation so that the photon pair concurrently has two pulse widths, namely, a temporally narrow width and a spectrally narrow width. Though this concurrence is seemingly contradictory, we can create such a photon pair by tailoring the quantum correlation between two photons.

  3. Photonic and Plasmonic Guided Modes in Graphene-Silicon Photonic Crystals

    DEFF Research Database (Denmark)

    Gu, Tingyi; Andryieuski, Andrei; Hao, Yufeng

    2015-01-01

    We report the results of systematic studies of plasmonic and photonic guided modes in large-area single-layer graphene integrated into a nanostructured silicon substrate. The interaction of light with graphene and substrate photonic crystals can be classified in distinct regimes depending......, filters, sensors, and photodetectors utilizing silicon photonic platforms....... on the relation of the photonic crystal lattice constant and the relevant modal wavelengths, that is, plasmonic, photonic, and free-space. By optimizing the design of the substrate, these resonant modes can increase the absorption of graphene in the infrared, facilitating enhanced performance of modulators...

  4. Nonlinear silicon photonics

    Science.gov (United States)

    Borghi, M.; Castellan, C.; Signorini, S.; Trenti, A.; Pavesi, L.

    2017-09-01

    Silicon photonics is a technology based on fabricating integrated optical circuits by using the same paradigms as the dominant electronics industry. After twenty years of fervid development, silicon photonics is entering the market with low cost, high performance and mass-manufacturable optical devices. Until now, most silicon photonic devices have been based on linear optical effects, despite the many phenomenologies associated with nonlinear optics in both bulk materials and integrated waveguides. Silicon and silicon-based materials have strong optical nonlinearities which are enhanced in integrated devices by the small cross-section of the high-index contrast silicon waveguides or photonic crystals. Here the photons are made to strongly interact with the medium where they propagate. This is the central argument of nonlinear silicon photonics. It is the aim of this review to describe the state-of-the-art in the field. Starting from the basic nonlinearities in a silicon waveguide or in optical resonator geometries, many phenomena and applications are described—including frequency generation, frequency conversion, frequency-comb generation, supercontinuum generation, soliton formation, temporal imaging and time lensing, Raman lasing, and comb spectroscopy. Emerging quantum photonics applications, such as entangled photon sources, heralded single-photon sources and integrated quantum photonic circuits are also addressed at the end of this review.

  5. Photon and photon reactions: elementary theoretical introduction

    International Nuclear Information System (INIS)

    Diu, B.

    The electromagnetic field and associated quanta, the photons, are simply and briefly studied. The conventional electromagnetism laws are recalled. Fundamental concepts such as gauge invariance, the electromagnetic current conservation, and photon behavior against the internal symmetries of strong interactions are simply introduced. Results and notations are applied to analysis of reactions where photons intervene in initial or final states (photoproduction) within the limits of amplitude properties in the conventional space-time. The helicity and invariant amplitude formalisms are compared [fr

  6. Nonlocal hyperconcentration on entangled photons using photonic module system

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Cong; Wang, Tie-Jun; Mi, Si-Chen [School of Science, Beijing University of Posts and Telecommunications, Beijing 100876 (China); State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Zhang, Ru [School of Science, Beijing University of Posts and Telecommunications, Beijing 100876 (China); State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China); School of Ethnic Minority Education, Beijing University of Posts and Telecommunications, Beijing 100876 (China); Wang, Chuan, E-mail: wangchuan@bupt.edu.cn [School of Science, Beijing University of Posts and Telecommunications, Beijing 100876 (China); State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing 100876 (China)

    2016-06-15

    Entanglement distribution will inevitably be affected by the channel and environment noise. Thus distillation of maximal entanglement nonlocally becomes a crucial goal in quantum information. Here we illustrate that maximal hyperentanglement on nonlocal photons could be distilled using the photonic module and cavity quantum electrodynamics, where the photons are simultaneously entangled in polarization and spatial-mode degrees of freedom. The construction of the photonic module in a photonic band-gap structure is presented, and the operation of the module is utilized to implement the photonic nondestructive parity checks on the two degrees of freedom. We first propose a hyperconcentration protocol using two identical partially hyperentangled initial states with unknown coefficients to distill a maximally hyperentangled state probabilistically, and further propose a protocol by the assistance of an ancillary single photon prepared according to the known coefficients of the initial state. In the two protocols, the total success probability can be improved greatly by introducing the iteration mechanism, and only one of the remote parties is required to perform the parity checks in each round of iteration. Estimates on the system requirements and recent experimental results indicate that our proposal is realizable with existing or near-further technologies.

  7. Nonlocal hyperconcentration on entangled photons using photonic module system

    International Nuclear Information System (INIS)

    Cao, Cong; Wang, Tie-Jun; Mi, Si-Chen; Zhang, Ru; Wang, Chuan

    2016-01-01

    Entanglement distribution will inevitably be affected by the channel and environment noise. Thus distillation of maximal entanglement nonlocally becomes a crucial goal in quantum information. Here we illustrate that maximal hyperentanglement on nonlocal photons could be distilled using the photonic module and cavity quantum electrodynamics, where the photons are simultaneously entangled in polarization and spatial-mode degrees of freedom. The construction of the photonic module in a photonic band-gap structure is presented, and the operation of the module is utilized to implement the photonic nondestructive parity checks on the two degrees of freedom. We first propose a hyperconcentration protocol using two identical partially hyperentangled initial states with unknown coefficients to distill a maximally hyperentangled state probabilistically, and further propose a protocol by the assistance of an ancillary single photon prepared according to the known coefficients of the initial state. In the two protocols, the total success probability can be improved greatly by introducing the iteration mechanism, and only one of the remote parties is required to perform the parity checks in each round of iteration. Estimates on the system requirements and recent experimental results indicate that our proposal is realizable with existing or near-further technologies.

  8. Single-photon sources

    International Nuclear Information System (INIS)

    Lounis, Brahim; Orrit, Michel

    2005-01-01

    The concept of the photon, central to Einstein's explanation of the photoelectric effect, is exactly 100 years old. Yet, while photons have been detected individually for more than 50 years, devices producing individual photons on demand have only appeared in the last few years. New concepts for single-photon sources, or 'photon guns', have originated from recent progress in the optical detection, characterization and manipulation of single quantum objects. Single emitters usually deliver photons one at a time. This so-called antibunching of emitted photons can arise from various mechanisms, but ensures that the probability of obtaining two or more photons at the same time remains negligible. We briefly recall basic concepts in quantum optics and discuss potential applications of single-photon states to optical processing of quantum information: cryptography, computing and communication. A photon gun's properties are significantly improved by coupling it to a resonant cavity mode, either in the Purcell or strong-coupling regimes. We briefly recall early production of single photons with atomic beams, and the operation principles of macroscopic parametric sources, which are used in an overwhelming majority of quantum-optical experiments. We then review the photophysical and spectroscopic properties and compare the advantages and weaknesses of various single nanometre-scale objects used as single-photon sources: atoms or ions in the gas phase and, in condensed matter, organic molecules, defect centres, semiconductor nanocrystals and heterostructures. As new generations of sources are developed, coupling to cavities and nano-fabrication techniques lead to improved characteristics, delivery rates and spectral ranges. Judging from the brisk pace of recent progress, we expect single photons to soon proceed from demonstrations to applications and to bring with them the first practical uses of quantum information

  9. Models for Photon-photon Total Cross-sections

    OpenAIRE

    Godbole, RM; Grau, A; Pancheri, G

    1999-01-01

    We present here a brief overview of recent models describing the photon-photon cross-section into hadrons. We shall show in detail results from the eikonal minijet model, with and without soft gluon summation.

  10. Relationship between anthropometric measures and sagittal spinal curvatures in adult male handball players

    Directory of Open Access Journals (Sweden)

    Ameer Mariam Abdul-Moneem

    2017-12-01

    Full Text Available Purpose. Increasing anthropometric measures bring considerable spinal loads during sports practice, which inversely affects the adaptation abilities of the spinal structures; this in turn influences the spinal curvatures. The study was conducted to explore the relationship between anthropometric measures and sagittal spinal curvatures in handball players. Method. The total of 83 male handball players were divided into 2 groups, depending on their body height: group 1 (age, 23.62 ± 2.07 years consisted of 40 handball players with height above average, group 2 (age, 24.63 ± 2.58 years consisted of 43 handball players with height below average. The thoracic and lumbar curvatures and trunk height were measured with the Formetric III 4D spine and posture analysis system. Results. The thoracic kyphosis of group 1 was significantly higher than that of group 2 (p = 0.038, without a significant difference in lumbar lordosis (p = 0.312, and significant difference in the coefficient of compensation between thoracic kyphosis and lumbar lordosis (p = 0.026. Group 1 showed strong positive correlation between body height and kyphotic angle (r = 0.897, and moderate positive correlation with lordosis angle (r = 0.496. In group 2, there was weak positive correlation with kyphotic angle (r = 0.381, and weak negative correlation with lumbar lordosis angle (r = -0.355. Conclusions. Increasing body height of handball players is associated with bigger kyphotic and lordotic angles. Owing to frequent sagittal asymmetric overloading of the spine during handball training, exercises that help maintain good posture and correct the thoracic kyphosis are required, especially for taller players.

  11. High brightness single photon sources based on photonic wires

    DEFF Research Database (Denmark)

    Claudon, J.; Bleuse, J.; Bazin, M.

    2009-01-01

    We present a novel single-photon-source based on the emission of a semiconductor quantum dot embedded in a single-mode photonic wire. This geometry ensures a very large coupling (> 95%) of the spontaneous emission to the guided mode. Numerical simulations show that a photon collection efficiency...

  12. High-field electron-photon interactions

    International Nuclear Information System (INIS)

    Hartemann, F V.

    1999-01-01

    Recent advances in novel technologies (including chirped-pulse amplification, femtosecond laser systems operating in the TW-PW range, high-gradient rf photoinjectors, and synchronized relativistic electron bunches with subpicosecond durations and THz bandwidths) allow experimentalists to study the interaction of relativistic electrons with ultrahigh-intensity photon fields. Ponderomotive scattering can accelerate these electrons with extremely high gradients in a three-dimensional vacuum laser focus. The nonlinear Doppler shift induced by relativistic radiation pressure in Compton backscattering is shown to yield complex nonlinear spectra which can be modified by using temporal laser pulse shaping techniques. Colliding laser pulses, where ponderomotive acceleration and Compton backscattering are combined, could also yield extremely short wavelength photons. Finally, one expects strong radiative corrections when the Doppler-upshifted laser wavelength approaches the Compton scale. These are discussed within the context of high-field classical electrodynamics, a new discipline borne out of the aforementioned innovations

  13. The FERMI-Elettra FEL Photon Transport System

    International Nuclear Information System (INIS)

    Zangrando, M.; Cudin, I.; Fava, C.; Godnig, R.; Kiskinova, M.; Masciovecchio, C.; Parmigiani, F.; Rumiz, L.; Svetina, C.; Turchet, A.; Cocco, D.

    2010-01-01

    The FERMI-Elettra free electron laser (FEL) user facility is under construction at Sincrotrone Trieste (Italy), and it will be operative in late 2010. It is based on a seeded scheme providing an almost perfect transform-limited and fully spatially coherent photon beam. FERMI-Elettra will cover the wavelength range 100 to 3 nm with the fundamental harmonics, and down to 1 nm with higher harmonics. We present the layout of the photon beam transport system that includes: the first common part providing on-line and shot-to-shot beam diagnostics, called PADReS (Photon Analysis Delivery and Reduction System), and 3 independent beamlines feeding the experimental stations. Particular emphasis is given to the solutions adopted to preserve the wavefront, and to avoid damage on the different optical elements. Peculiar FEL devices, not common in the Synchrotron Radiation facilities, are described in more detail, e.g. the online photon energy spectrometer measuring shot-by-shot the spectrum of the emitted radiation, the beam splitting and delay line system dedicated to cross/auto correlation and pump-probe experiments, and the wavefront preserving active optics adapting the shape and size of the focused spot to meet the needs of the different experiments.

  14. A modified sagittal spine postural classification and its relationship to deformities and spinal mobility in a chinese osteoporotic population.

    Directory of Open Access Journals (Sweden)

    Hua-Jun Wang

    Full Text Available BACKGROUND: Abnormal posture and spinal mobility have been demonstrated to cause functional impairment in the quality of life, especially in the postmenopausal osteoporotic population. Most of the literature studies focus on either thoracic kyphosis or lumbar lordosis, but not on the change of the entire spinal alignment. Very few articles reported the spinal alignment of Chinese people. The purpose of this study was threefold: to classify the spinal curvature based on the classification system defined by Satoh consisting of the entire spine alignment; to identify the change of trunk mobility; and to relate spinal curvature to balance disorder in a Chinese population. METHODOLOGY/PRINCIPAL FINDINGS: 450 osteoporotic volunteers were recruited for this study. Spinal range of motion and global curvature were evaluated noninvasively using the Spinal-Mouse® system and sagittal postural deformities were characterized. RESULTS: We found a new spine postural alignment consisting of an increased thoracic kyphosis and decreased lumbar lordosis which we classified as our modified round back. We did not find any of Satoh's type 5 classification in our population. Type 2 sagittal alignment was the most common spinal deformity (38.44%. In standing, thoracic kyphosis angles in types 2 (58.34° and 3 (58.03° were the largest and lumbar lordosis angles in types 4 (13.95° and 5 (-8.61° were the smallest. The range of flexion (ROF and range of flexion-extension (ROFE of types 2 and 3 were usually greater than types 4 and 5, with type 1 being the largest. CONCLUSIONS/SIGNIFICANCE: The present study classified and compared for the first time the mobility, curvature and balance in a Chinese population based on the entire spine alignment and found types 4 and 5 to present the worst balance and mobility. This study included a new spine postural alignment classification that should be considered in future population studies.

  15. Sagittal abdominal diameter shows better correlation with cardiovascular risk factors than waist circumference and BMI

    OpenAIRE

    de Souza, Natalia Cavalheri; de Oliveira, Erick Prado

    2013-01-01

    Background Obesity (abdominal adiposity) is a risk factor for cardiovascular diseases and the most used methods to measure the adiposity are body mass index (BMI), waist circumference (WC), and sagittal abdominal diameter (SAD). Objective To correlate BMI, WC, and SAD with biochemical parameters and blood pressure in adults. Methods A non-experimental exploratory/descriptive and cross sectional study was developed and it was assessed 133 subjects (59 men and 74 women) aging between 18 and 87?...

  16. Final-photon polarization in the scattering of photons by high-energy electrons

    International Nuclear Information System (INIS)

    Choi, J.; Choi, S.Y.; Ie, S.H.; Song, H.S.; Good, R.H. Jr.

    1987-01-01

    A general method for calculating the polarization of the outgoing photon beam in any reaction is presented. As an example the method is applied to the high-energy photon beam produced in Compton scattering of a laser beam by a high-energy electron beam. The Stokes parameters of the outgoing photon beam, relative to a unit vector normal to the photon momentum and including their dependence on the polarization of incident photon and electron beams, are obtained explicitly. It is expected that this method will be useful, both in photon production reactions and in the subsequent high-energy photon reactions

  17. 2-Photon tandem device for water splitting

    DEFF Research Database (Denmark)

    Seger, Brian; Castelli, Ivano Eligio; Vesborg, Peter Christian Kjærgaard

    2014-01-01

    Within the field Of photocatalytic water splitting there are several strategies to achieve the goal of efficient and cheap photocatalytic water splitting. This work examines one particular strategy by focusing on monolithically stacked, two-photon photoelectrochemical cells. The overall aim...... for photocatalytic water splitting by using a large bandgap photocathode and a low bandgap photoanode with attached protection layers....

  18. Full utilization of semi-Dirac cones in photonics

    Science.gov (United States)

    Yasa, Utku G.; Turduev, Mirbek; Giden, Ibrahim H.; Kurt, Hamza

    2018-05-01

    In this study, realization and applications of anisotropic zero-refractive-index materials are proposed by exposing the unit cells of photonic crystals that exhibit Dirac-like cone dispersion to rotational symmetry reduction. Accidental degeneracy of two Bloch modes in the Brillouin zone center of two-dimensional C2-symmetric photonic crystals gives rise to the semi-Dirac cone dispersion. The proposed C2-symmetric photonic crystals behave as epsilon-and-mu-near-zero materials (ɛeff≈ 0 , μeff≈ 0 ) along one propagation direction, but behave as epsilon-near-zero material (ɛeff≈ 0 , μeff≠ 0 ) for the perpendicular direction at semi-Dirac frequency. By extracting the effective medium parameters of the proposed C4- and C2-symmetric periodic media that exhibit Dirac-like and semi-Dirac cone dispersions, intrinsic differences between isotropic and anisotropic materials are investigated. Furthermore, advantages of utilizing semi-Dirac cone materials instead of Dirac-like cone materials in photonic applications are demonstrated in both frequency and time domains. By using anisotropic transmission behavior of the semi-Dirac materials, photonic application concepts such as beam deflectors, beam splitters, and light focusing are proposed. Furthermore, to the best of our knowledge, semi-Dirac cone dispersion is also experimentally demonstrated for the first time by including negative, zero, and positive refraction states of the given material.

  19. Spinal sagittal contour affecting falls: cut-off value of the lumbar spine for falls.

    Science.gov (United States)

    Ishikawa, Yoshinori; Miyakoshi, Naohisa; Kasukawa, Yuji; Hongo, Michio; Shimada, Yoichi

    2013-06-01

    Spinal deformities reportedly affect postural instability or falls. To prevent falls in clinical settings, the determination of a cut-off angle of spinal sagittal contour associated with increase risk for falls would be useful for screening for high-risk fallers. The purpose of this study was to calculate the spinal sagittal contour angle associated with increased risk for falls during medical checkups in community dwelling elders. The subjects comprised 213 patients (57 men, 156 women) with a mean age of 70.1 years (range, 55-85 years). The upright and flexion/extension thoracic kyphosis and lumbar lordosis angles, and the spinal inclination were evaluated with SpinalMouse(®). Postural instability was evaluated by stabilometry, using the total track length (LNG), enveloped areas (ENV), and track lengths in the lateral and anteroposterior directions (X LNG and Y LNG, respectively). The back extensor strength (BES) was measured using a strain-gauge dynamometer. The relationships among the parameters were analyzed statistically. Age, lumbar lordosis, spinal inclination, LNG, X LNG, Y LNG, and BES were significantly associated with falls (Pfalls about lumbar lordosis angles revealed that angles of 3° and less were significant for falls. The present findings suggest that increased age, spinal inclination, LNG, X LNG, Y LNG, and decreased BES and lumbar lordosis, are associated with falls. An angle of lumbar lordosis of 3° or less was associated with falls in these community-dwelling elders. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Search for SUSY in final states with photons at CMS

    Directory of Open Access Journals (Sweden)

    Ntomari Eleni

    2013-05-01

    Full Text Available Résumé The Compact Muon Solenoid (CMS collaboration has developed a complete program of searches beyond the Standard Model (SM covering a wide range of final states. This document focuses on searches in final states with photons and missing transverse energy ETmiss organised in three analyses. The first two include comparison of the ETmiss distribution (isolation sideband method in events with either at least two photons plus at least one hadronic jet, or at least one photon plus at least two hadronic jets. The third analysis corresponds to a new approach, the Jet-Gamma Balance (JGB method, for events with at least one photon plus at least three hadronic jets.We observe no significant deviations from the SM expectation and thus derive upper limits on the signal cross section at the 95% confidence level (CL for a range of squark, gluino and neutralino mass points in the Gauge Mediated Supersymmetry Breaking scenario.

  1. Physics at high energy photon photon colliders

    International Nuclear Information System (INIS)

    Chanowitz, M.S.

    1994-06-01

    I review the physic prospects for high energy photon photon colliders, emphasizing results presented at the LBL Gamma Gamma Collider Workshop. Advantages and difficulties are reported for studies of QCD, the electroweak gauge sector, supersymmetry, and electroweak symmetry breaking

  2. Tailoring single-photon and multiphoton probabilities of a single-photon on-demand source

    International Nuclear Information System (INIS)

    Migdall, A.L.; Branning, D.; Castelletto, S.

    2002-01-01

    As typically implemented, single-photon sources cannot be made to produce single photons with high probability, while simultaneously suppressing the probability of yielding two or more photons. Because of this, single-photon sources cannot really produce single photons on demand. We describe a multiplexed system that allows the probabilities of producing one and more photons to be adjusted independently, enabling a much better approximation of a source of single photons on demand

  3. The method of impedance transformation for electromagnetic waves propagating in one-dimension plasma photonic crystal

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Jingfeng; Yuan, Chengxun, E-mail: yuancx@hit.edu.cn, E-mail: zhouzx@hit.edu.cn; Gao, Ruilin; Jia, Jieshu; Wang, Ying; Zhou, Zhongxiang, E-mail: yuancx@hit.edu.cn, E-mail: zhouzx@hit.edu.cn; Wang, Xiaoou [Department of Physics, Harbin Institute of Technology, Harbin 150001 (China); Wu, Jian [National Key Laboratory of Electromagnetic Environment (LEME), China Research Institute of Radio Wave Propagation, Beijing 102206 (China); Li, Hui [Department of Physics, Harbin Institute of Technology, Harbin 150001 (China); National Key Laboratory of Electromagnetic Environment (LEME), China Research Institute of Radio Wave Propagation, Beijing 102206 (China)

    2016-08-15

    This study focuses on the transmission of normal-incidence electromagnetic waves in one-dimensional plasma photonic crystals. Using the Maxwell's equations in a medium, a method that is based on the concept of impendence is employed to perform the simulation. The accuracy of the method was evaluated by simulating a one-layer plasma and conventional photonic crystal. In frequency-domain, the transmission and reflection coefficients in the unmagnetized plasma photonic crystal were calculated, and the influence factors on plasma photonic crystals including dielectric constants of dielectric, spatial period, filling factor, plasma frequency, and collision frequency were studied.

  4. Engineering Photon-Photon Interactions within Rubidium-Filled Waveguides

    Science.gov (United States)

    Perrella, C.; Light, P. S.; Vahid, S. Afshar; Benabid, F.; Luiten, A. N.

    2018-04-01

    Strong photon-photon interactions are a required ingredient for deterministic two-photon optical quantum logic gates. Multiphoton transitions in dense atomic vapors have been shown to be a promising avenue for producing such interactions. The strength of a multiphoton interaction can be enhanced by conducting the interaction in highly confined geometries such as small-cross-section optical waveguides. We demonstrate, both experimentally and theoretically, that the strength of such interactions scale only with the optical mode diameter, d , not d2 as might be initially expected. This weakening of the interaction arises from atomic motion inside the waveguides. We create an interaction between two optical signals, at 780 and 776 nm, using the 5 S1 /2→5 D5 /2 two-photon transition in rubidium vapor within a range of hollow-core fibers with different core sizes. The interaction strength is characterized by observing the absorption and phase shift induced on the 780-nm beam, which is in close agreement with theoretical modeling that accounts for the atomic motion inside the fibers. These observations demonstrate that transit-time effects upon multiphoton transitions are of key importance when engineering photon-photon interactions within small-cross-section waveguides that might otherwise be thought to lead to enhanced optical nonlinearity through increased intensities.

  5. Upper midbrain profile sign and cingulate sulcus sign. MRI findings on sagittal images in idiopathic normal-pressure hydrocephalus, Alzheimer's disease, and progressive supranuclear palsy

    International Nuclear Information System (INIS)

    Adachi, Michito; Ohshima, Fumi; Kawanami, Toru; Kato, Takeo

    2006-01-01

    On magnetic resonance imaging (MRI) sagittal sections, we sometimes encounter abnormal aspects of the superior profile of the midbrain and the cingulate sulcus in patients with dementia. In this preliminary study, we refer to these findings as the ''upper midbrain profile sign'' and the cingulate sulcus sign.'' We prospectively evaluated the usefulness of these signs for the diagnosis of idiopathic normal-pressure hydrocephalus (iNPH), Alzheimer's disease (AD) and progressive supranuclear palsy (PSP). We evaluated the upper midbrain profile sign and the cingulate sulcus sign on MRI sagittal images obtained from 21 people with headaches but no neurological deficit (controls), 10 iNPH patients, 11 AD patients, and 5 PSP patients. The upper midbrain profile sign indicated a concave shape to the superior profile of the midbrain on mid-sagittal images, and the cingulate sulcus sign indicated a narrow, tight aspect of the posterior part of the cingulate sulcus on paramedian-sagittal images. These signs were never seen in any images from the controls. The upper midbrain profile sign was seen in 7 of 10 patients with iNPH, 5 of 11 with AD, and 3 of 5 with PSP. The cingulate sulcus sign was seen in all 10 patients with iNPH but was never seen in any patient with AD or PSP. The upper midbrain profile sign could support a diagnosis of PSP but cannot discriminate among iNPH, AD, and PSP. In contrast, the cingulate sulcus sign has a very high sensitivity for iNPH and should facilitate the distinction of iNPH from other dementias. In the clinical setting, it is momentous to evaluate these signs easily by one simple MRI sequence. (author)

  6. Photon technology. Laser processing technology; Photon technology. Laser process gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    Survey has been conducted to develop laser processing technology utilizing the interaction between substance and photon. This is a part of the leading research on photon technology development. The photon technology development is aimed at novel technology development highly utilizing the quantum nature of photons. In the field of laser processing, high quality photons are used as tools, special functions of atoms and molecules will be discovered, and processing for functional fabrication (photon machining) will be established. A role of laser processing in industries has become significant, which is currently spreading not only into cutting and welding of materials and scalpels but also into such a special field as ultrafine processing of materials. The spreading is sometimes obstructed due to the difficulty of procurement of suitable machines and materials, and the increase of cost. The purpose of this study is to develop the optimal laser technology, to elucidate the interaction between substance and photon, and to develop the laser system and the transmission and regulation systems which realize the optimal conditions. 387 refs., 115 figs., 25 tabs.

  7. Sagittal-Plane Knee Moment During Gait and Knee Cartilage Thickness.

    Science.gov (United States)

    Schmitz, Randy J; Harrison, David; Wang, Hsin-Min; Shultz, Sandra J

    2017-06-02

      Understanding the factors associated with thicker cartilage in a healthy population is important when developing strategies aimed at minimizing the cartilage thinning associated with knee osteoarthritis progression. Thicker articular cartilage is commonly thought to be healthier cartilage, but whether the sagittal-plane biomechanics important to gait are related to cartilage thickness is unknown.   To determine the relationship of a weight-bearing region of the medial femoral condyle's cartilage thickness to sagittal gait biomechanics in healthy individuals.   Descriptive laboratory study.   Laboratory.   Twenty-eight healthy participants (15 women: age = 21.1 ± 2.1 years, height = 1.63 ± 0.07 m, weight = 64.6 ± 9.9 kg; 13 men: age = 22.1 ± 2.9 years, height = 1.79 ± 0.05 m, weight = 75.2 ± 9.6 kg).   Tibiofemoral angle (°) was obtained via goniometric assessment, thickness of the medial femoral condyle cartilage (mm) was obtained via ultrasound imaging, and peak internal knee-extensor moment (% body weight · height) was measured during 10 trials of over-ground walking at a self-selected pace. We used linear regression to examine the extent to which peak internal knee-extensor moment predicted cartilage thickness after accounting for tibiofemoral angle and sex.   Sex and tibiofemoral angle (12.3° ± 3.2°) were entered in the initial step as control factors (R 2 = 0.01, P = .872). In the final step, internal knee-extensor moment (1.5% ± 1.3% body weight · height) was entered, which resulted in greater knee-extensor moment being related to greater cartilage thickness (2.0 ± 0.3 mm; R 2 Δ = 0.31, PΔ = .003).   Individuals who walked with a greater peak internal knee-extensor moment during gait had a cartilage structure that is generally considered beneficial in a healthy population. Our study offers promising findings that a potentially modifiable biomechanical factor is associated with cartilage status in a healthy population

  8. Photon-phonon interaction in photonic crystals

    International Nuclear Information System (INIS)

    Ueta, T

    2010-01-01

    Photon-phonon interaction on the analogy of electron-phonon interaction is considered in one-dimensional photonic crystal. When lattice vibration is artificially introduced to the photonic crystal, a governing equation of electromagnetic field is derived. A simple model is numerically analysed and the following novel phenomena are found out. The lattice vibration generates the light of frequency which added the integral multiple of the vibration frequency to that of the incident wave and also amplifies the incident wave resonantly. On a resonance, the amplification factor increases very rapidly with the number of layers increases. Resonance frequencies change with the phases of lattice vibration. The amplification phenomenon is analytically discussed for low frequency of the lattice vibration.

  9. Photon structure and the production of jets, hadrons, and prompt photons

    International Nuclear Information System (INIS)

    Klasen, M.

    1999-01-01

    We give a pedagogical introduction to hard photoproduction processes at HERA, including the production of jets, hadrons, and prompt photons. Recent theoretical developments in the three areas are reviewed. In summary, hard photoproduction processes can provide very useful information on the hadronic structure of the photon, in particular on the gluon density, which is complimentary to the information coming from deep inelastic photon-photon scattering at electron-positron colliders. Among the different hadronic final states, jets are most easily accessible experimentally and phenomenologically. On the other hand, inclusive hadron production offers the possibility to test the universality of hadron fragmentation functions and measure the photon structure down to very low values of p T and x γ . Prompt photon production suffers from a reduced cross section and limited data, but allows for the additional testing of photon fragmentation functions

  10. Rolled-up nanotechnology: 3D photonic materials by design

    International Nuclear Information System (INIS)

    Böttner, Stefan; Jorgensen, Matthew R.; Schmidt, Oliver G.

    2016-01-01

    Rolled-up nanotechnology involves the deposition of strained material layers for subsequent release and relaxation into functional structures with applications spanning several disciplines. Originally developed for use with semiconductor materials, over the last decade the processes involved in rolled-up nanotechnology have been applied across a wide palette of materials resulting in applications (among others) in micro robotics, energy storage, electronics, and photonics. Here we highlight the key advancements and future directions in rolled-up photonics, focusing on the diverse demonstrations of rolled-up three-dimensional microresonators which enable integrated sensing, micro-lasing, and out-of-plane routing of light.

  11. TWO-PHOTON PHYSICS IN NUCLEUS-NUCLEUS COLLISIONS AT RHIC

    International Nuclear Information System (INIS)

    Nystrand, J.; Klein, S.

    1998-01-01

    Ultra-relativistic heavy-ions carry strong electromagnetic and nuclear fields. Interactions between these fields in peripheral nucleus-nucleus collisions can probe many interesting physics topics. This presentation will focus on coherent two-photon and photonuclear processes at RHIC. The rates for these interactions will be high. The coherent coupling of all the protons in the nucleus enhances the equivalent photon flux by a factor Z 2 up to an energy of ∼ 3 GeV. The plans for studying coherent interactions with the STAR experiment will be discussed. Experimental techniques for separating signal from background will be presented

  12. Two-photon physics in nucleus-nucleus collisions at RHIC

    International Nuclear Information System (INIS)

    Nystrand, J.; Klein, S.

    1998-01-01

    Ultra-relativistic heavy-ions carry strong electromagnetic and nuclear fields. Interactions between these fields in peripheral nucleus-nucleus collisions can probe many interesting physics topics. This presentation will focus on coherent two-photon and photonuclear processes at RHIC. The rates for these interactions will be high. The coherent coupling of all the protons in the nucleus enhances the equivalent photon flux by a factor Z 2 up to an energy of ∼ 3 GeV. The plans for studying coherent interactions with the STAR experiment will be discussed. Experimental techniques for separating signal from background will be presented

  13. Moyamoya disease and sagittal sinus thrombosis in a child with Down's syndrome

    International Nuclear Information System (INIS)

    Del-Rio Camacho, G.; Leal Orozco, A.; Camino Lopez, M.; Ruiz-Moreno, M.; Perez-Higueras, A.; Al-Assir, I.

    2001-01-01

    A girl with Down's syndrome, moyamoya disease and sagittal sinus thrombosis is described. She was diagnosed after acute neurological deterioration by MRI and angiography. Recombinant tissue plasminogen activator (r-TPA) was injected locally to recanalise the thrombus. The patient's condition significantly improved and she was discharged. After 2 years of follow-up the child remains asymptomatic. Moyamoya syndrome and cerebral venous thrombosis should not be overlooked as a cause of acute neurological deterioration in a child with Down's syndrome. MRA appears to be a safe and accurate alternative to traditional angiography for the diagnosis of moyamoya disease. Local fibrinolysis with r-TPA is the treatment of choice for cerebral venous thrombosis due to its safety and efficacy. (orig.)

  14. Emergency surgical management of traumatic superior sagittal sinus injury: An unusual case

    Directory of Open Access Journals (Sweden)

    Sudhansu Sekhar Mishra

    2012-01-01

    Full Text Available Head injuries following fall of heavy objects are not very uncommon in developing countries. However, compound depressed skull fracture with superior sagittal sinus (SSS laceration caused by a flying asbestos fragment in a stormy afternoon is an unusual mode of head injury. We report such an unusual case of compound depressed skull fracture by an asbestos fragment injuring the middle third of SSS and its successful surgical management in a 14-year-old child. The role of computed tomography (CT scan of head with 3D reconstruction is highlighted. Early steps taken in this case to check the profuse bleeding, which helped save the life of this boy is interesting to note.

  15. Photon-number correlation for quantum enhanced imaging and sensing

    Science.gov (United States)

    Meda, A.; Losero, E.; Samantaray, N.; Scafirimuto, F.; Pradyumna, S.; Avella, A.; Ruo-Berchera, I.; Genovese, M.

    2017-09-01

    In this review we present the potentialities and the achievements of the use of non-classical photon-number correlations in twin-beam states for many applications, ranging from imaging to metrology. Photon-number correlations in the quantum regime are easily produced and are rather robust against unavoidable experimental losses, and noise in some cases, if compared to the entanglement, where losing one photon can completely compromise the state and its exploitable advantages. Here, we will focus on quantum enhanced protocols in which only phase-insensitive intensity measurements (photon-number counting) are performed, which allow probing the transmission/absorption properties of a system, leading, for example, to innovative target detection schemes in a strong background. In this framework, one of the advantages is that the sources experimentally available emit a wide number of pair-wise correlated modes, which can be intercepted and exploited separately, for example by many pixels of a camera, providing a parallelism, essential in several applications, such as wide-field sub-shot-noise imaging and quantum enhanced ghost imaging. Finally, non-classical correlation enables new possibilities in quantum radiometry, e.g. the possibility of absolute calibration of a spatial resolving detector from the on-off single-photon regime to the linear regime in the same setup.

  16. Measurement of Isolated Prompt Photon Production in Photon-Photon Collisions at $\\sqrt{s_{ee}}$=183-209 GeV

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Allison, John; Amaral, P.; Anagnostou, G.; Anderson, K.J.; Arcelli, S.; Asai, S.; Axen, D.; Azuelos, G.; Bailey, I.; Barberio, E.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Boeriu, O.; Bock, P.; Boutemeur, M.; Braibant, S.; Brigliadori, L.; Brown, Robert M.; Buesser, K.; Burckhart, H.J.; Campana, S.; Carnegie, R.K.; Caron, B.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Csilling, A.; Cuffiani, M.; Dado, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Donkers, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Etzion, E.; Fabbri, F.; Feld, L.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Furtjes, A.; Gagnon, P.; Gary, John William; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harder, K.; Harel, A.; Harin-Dirac, M.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Hensel, C.; Herten, G.; Heuer, R.D.; Hill, J.C.; Hoffman, Kara Dion; Horvath, D.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanaya, N.; Kanzaki, J.; Karapetian, G.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kim, D.H.; Klein, K.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kormos, Laura L.; Kramer, T.; Krieger, P.; von Krogh, J.; Kruger, K.; Kuhl, T.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Layter, J.G.; Leins, A.; Lellouch, D.; Lettso, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, J.; Macpherson, A.; Mader, W.; Marcellini, S.; Martin, A.J.; Masetti, G.; Mashimo, T.; Mattig, Peter; McDonald, W.J.; McKenna, J.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Menges, W.; Merritt, F.S.; Mes, H.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Moed, S.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Nanjo, H.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Okpara, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poli, B.; Polok, J.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Roney, J.M.; Rosati, S.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schoerner-Sadenius, Thomas; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Sherwood, P.; Siroli, G.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spano, F.; Stahl, A.; Stephens, K.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Taylor, R.J.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vollmer, C.F.; Vannerem, P.; Vertesi, R.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Waller, D.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wetterling, D.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2004-01-01

    For the first time at LEP the production of prompt photons is studied in the collisions of quasi-real photons using the OPAL data taken at e+e- centre-of-mass energies between 183 GeV and 209 GeV. The total inclusive production cross-section for isolated prompt photons in the kinematic range of photon transverse momentum larger than 3.0 GeV and absolute photon pseudorapidity less than 1 is determined to be 0.32 +- 0.04 (stat) +- 0.04 (sys) pb. Differential cross-sections are compared to the predictions of a next-to-leading-order (NLO) calculation.

  17. Fluorescent nano-particles for multi-photon thermal sensing

    Energy Technology Data Exchange (ETDEWEB)

    Jaque, D., E-mail: daniel.jaque@uam.es [Fluorescence Imaging Group, Universidad Autonoma de Madrid, Madrid 28049 (Spain); Maestro, L.M.; Escudero, E. [Fluorescence Imaging Group, Universidad Autonoma de Madrid, Madrid 28049 (Spain); Rodriguez, E. Martin; Capobianco, J.A. [Department of Chemistry and Biochemistry, Concordia University, 7141 Sherbrooke St. W., Montreal, QC, Canada H4B 1R6 (Canada); Vetrone, F. [Institut National de la Recherche Scientifique-Energie, Materiaux et Telecommunications, Universite du Quebec, Varennes, QC, Canada J3X 1S2 (Canada); Juarranz de la Fuente, A.; Sanz-Rodriguez, F. [Departamento de Biologia, Facultad de Ciencias, Universidad Autonoma de Madrid, Madrid 28049 (Spain); Iglesias-de la Cruz, M.C. [Departamento de Fisiologia, Facultad de Medicina, Universidad Autonoma de Madrid, C/Arzobispo Morcillo s/n, 29029 Madrid (Spain); Jacinto, C.; Rocha, U. [Grupo de Fotonica e Fluidos Complexos, Instituto de Fisica, Universidade Federal de Alagoas, 57072-970 Maceio, Alagoas (Brazil); Garcia Sole, J. [Fluorescence Imaging Group, Universidad Autonoma de Madrid, Madrid 28049 (Spain)

    2013-01-15

    In this work we report on the ability of Er/Yb co-doped NaYF{sub 4} nano-crystals and CdTe Quantum Dots as two-photon excited fluorescent nano-thermometers. The basic physical phenomena causing the thermal sensitivity of the two-photon excited emission bands have been discussed and the maximum thermal resolution achievable in each case has been estimated. The practical application of both systems for thermal sensing at the micro-scale in biological systems is demonstrated. In particular, they have been used to evaluate the thermal loading induced by tightly focused laser beams in both living cells and fluids. - Highlights: Black-Right-Pointing-Pointer Two-photon-excited optical probes capable of thermal sensing are introduced. Black-Right-Pointing-Pointer The physics at the basis of thermal sensing is identified for each case. Black-Right-Pointing-Pointer Optical nano-thermometers are used to determine laser induced heating in cells and fluids.

  18. Superior Sagittal Sinus Thrombosis Complicating Typhoid Fever in a Teenager

    Directory of Open Access Journals (Sweden)

    P. O. Okunola

    2012-01-01

    Full Text Available Cerebral venous sinus (sinovenous thrombosis (CSVT is a rare life-threatening disorder in childhood that is often misdiagnosed. CSVT encompasses cavernous sinus thrombosis, lateral sinus thrombosis, and superior sagittal sinus thrombosis (SSST. We present an adolescent girl who was well until two weeks earlier when she had a throbbing frontal headache and fever with chills; she later had dyspnoea, jaundice, melena stool, multiple seizures, nuchal rigidity, and monoparesis of the right lower limb a day before admission. Urine test for Salmonella typhi Vi antigen was positive, and Widal reaction was significant. Serial cranial computerized tomography scans revealed an expanding hypodense lesion in the parafalcine region consistent with SSST or a parasagittal abscess. Inadvertent left parietal limited craniectomy confirmed SSST. She recovered completely with subsequent conservative management. Beyond neuropsychiatric complications of Typhoid fever, CSVT should be highly considered when focal neurologic deficits are present.

  19. On Approaching the Ultimate Limits of Communication Using a Photon-Counting Detector

    Science.gov (United States)

    Erkmen, Baris I.; Moision, Bruce E.; Dolinar, Samuel J.; Birnbaum, Kevin M.; Divsalar, Dariush

    2012-01-01

    Coherent states achieve the Holevo capacity of a pure-loss channel when paired with an optimal measurement, but a physical realization of this measurement scheme is as of yet unknown, and it is also likely to be of high complexity. In this paper, we focus on the photon-counting measurement and study the photon and dimensional efficiencies attainable with modulations over classical- and nonclassical-state alphabets. We analyze two binary modulation architectures that improve upon the dimensional versus photon efficiency tradeoff achievable with the state-of-the-art coherent-state on-off keying modulation. We show that at high photon efficiency these architectures achieve an efficiency tradeoff that differs from the best possible tradeoff--determined by the Holevo capacity--by only a constant factor. The first architecture we analyze is a coherent-state transmitter that relies on feedback from the receiver to control the transmitted energy. The second architecture uses a single-photon number-state source.

  20. Quantum entanglement and phase transition in a two-dimensional photon-photon pair model

    International Nuclear Information System (INIS)

    Zhang Jianjun; Yuan Jianhui; Zhang Junpei; Cheng Ze

    2013-01-01

    We propose a two-dimensional model consisting of photons and photon pairs. In the model, the mixed gas of photons and photon pairs is formally equivalent to a two-dimensional system of massive bosons with non-vanishing chemical potential, which implies the existence of two possible condensate phases. Using the variational method, we discuss the quantum phase transition of the mixed gas and obtain the critical coupling line analytically. Moreover, we also find that the phase transition of the photon gas can be interpreted as enhanced second harmonic generation. We then discuss the entanglement between photons and photon pairs. Additionally, we also illustrate how the entanglement between photons and photon pairs can be associated with the phase transition of the system.

  1. Quantum Optics with Photonic Nanowires and Photonic Trumpets: Basics and Applications

    DEFF Research Database (Denmark)

    Gerard, J.; Claudon, J.; Munsch, M.

    , the node of future quantum networks. Besides optical microcavities [1], photonic wires have recently demonstrated in this context an appealing potential [2, 3]. For instance, single photon sources (SPS) based on a single quantum dot in a vertical photonic wire with integrated bottom mirror and tapered tip...... have enabled for the ¯rst time to achieve simultaneously a very high e±ciency (0.72 photon per pulse) and a very pure single photon emission (g(2)(0) control of the spontaneous emission of embedded emitters [4...

  2. Why I am optimistic about the silicon-photonic route to quantum computing

    Directory of Open Access Journals (Sweden)

    Terry Rudolph

    2017-03-01

    Full Text Available This is a short overview explaining how building a large-scale, silicon-photonic quantum computer has been reduced to the creation of good sources of 3-photon entangled states (and may simplify further. Given such sources, each photon needs to pass through a small, constant, number of components, interfering with at most 2 other spatially nearby photons, and current photonics engineering has already demonstrated the manufacture of thousands of components on two-dimensional semiconductor chips with performance that, once scaled up, allows the creation of tens of thousands of photons entangled in a state universal for quantum computation. At present the fully integrated, silicon-photonic architecture we envisage involves creating the required entangled states by starting with single-photons produced non-deterministically by pumping silicon waveguides (or cavities combined with on-chip filters and nanowire superconducting detectors to herald that a photon has been produced. These sources are multiplexed into being near-deterministic, and the single photons then passed through an interferometer to non-deterministically produce small entangled states—necessarily multiplexed to near-determinism again. This is followed by a “ballistic” scattering of the small-scale entangled photons through an interferometer such that some photons are detected, leaving the remainder in a large-scale entangled state which is provably universal for quantum computing implemented by single-photon measurements. There are a large number of questions regarding the optimum ways to make and use the final cluster state, dealing with static imperfections, constructing the initial entangled photon sources and so on, that need to be investigated before we can aim for millions of qubits capable of billions of computational time steps. The focus in this article is on the theoretical side of such questions.

  3. Photon energy tunability of advanced photon source undulators

    International Nuclear Information System (INIS)

    Viccaro, P.J.; Shenoy, G.K.

    1987-08-01

    At a fixed storage ring energy, the energy of the harmonics of an undulator can be shifted or ''tuned'' by changing the magnet gap of the device. The possible photon energy interval spanned in this way depends on the undulator period, minimum closed gap, minimum acceptable photon intensity and storage ring energy. The minimum magnet gap depends directly on the stay clear particle beam aperture required for storage ring operation. The tunability of undulators planned for the Advanced Photon Source with first harmonic photon energies in the range of 5 to 20 keV are discussed. The results of an analysis used to optimize the APS ring energy is presented and tunability contours and intensity parameters are presented for two typical classes of devices

  4. Complex photonic structures

    International Nuclear Information System (INIS)

    Wiersma, D.S.

    2013-01-01

    We discuss in detail the optical properties of complex photonic structures, in particular those with a dominating disorder component. We will focus on their general transport properties, as well as on their use as light sources (random lasers). The basis for the theory of multiple light scattering in random systems will be explained as a tutorial introduction to the topic, including the explicit calculation of the effect of coherent backscattering. We will discuss various structures that go beyond regular disordered ones, in particular Levy glasses, liquid crystals, and quasicrystals, and show examples of their optical properties both from a conceptual and practical point of view.

  5. Photonic integration and photonics-electronics convergence on silicon platform

    CERN Document Server

    Liu, Jifeng; Baba, Toshihiko; Vivien, Laurent; Xu, Dan-Xia

    2015-01-01

    Silicon photonics technology, which has the DNA of silicon electronics technology, promises to provide a compact photonic integration platform with high integration density, mass-producibility, and excellent cost performance. This technology has been used to develop and to integrate various photonic functions on silicon substrate. Moreover, photonics-electronics convergence based on silicon substrate is now being pursued. Thanks to these features, silicon photonics will have the potential to be a superior technology used in the construction of energy-efficient cost-effective apparatuses for various applications, such as communications, information processing, and sensing. Considering the material characteristics of silicon and difficulties in microfabrication technology, however, silicon by itself is not necessarily an ideal material. For example, silicon is not suitable for light emitting devices because it is an indirect transition material. The resolution and dynamic range of silicon-based interference de...

  6. Single-Photon Technologies Based on Quantum-Dots in Photonic Crystals

    DEFF Research Database (Denmark)

    Lehmann, Tau Bernstorff

    -photon purity under quasi-resonantexcitation. Furthermore the waveguide based platform demonstrates indistinguishable single-photonsat timescales up to 13 ns.A setup for active demultiplexing of single-photons to a three-fold single-photon state is proposed.Using a fast electro-optical modulator, single...

  7. Search for dark photons using data from CRESST-II Phase 2

    Science.gov (United States)

    Gütlein, A.; Angloher, G.; Bento, A.; Bucci, C.; Canonica, L.; Defay, X.; Erb, A.; Feilitzsch, F. v.; Ferreiro Iachellini, N.; Gorla, P.; Hauff, D.; Jochum, J.; Kiefer, M.; Kluck, H.; Kraus, H.; Lanfranchi, J.-C.; Loebell, J.; Mancuso, M.; Münster, A.; Pagliarone, C.; Petricca, F.; Potzel, W.; Pröbst, F.; Puig, R.; Reindl, F.; Schäffner, K.; Schieck, J.; Schönert, S.; Seidel, W.; Stahlberg, M.; Stodolsky, L.; Strandhagen, C.; Strauss, R.; Tanzke, A.; Trinh Thi, H. H.; Türkoǧlu, C.; Uffinger, M.; Ulrich, A.; Usherov, I.; Wawoczny, S.; Willers, M.; Wüstrich, M.; Zöller, A.

    2017-09-01

    Understanding the nature and origin of dark matter is one of the most important challenges for modern particle physics. During the previous decade the sensitivities of direct dark matter searches have improved by several orders of magnitude. These experiments focus their work mainly on the search for dark-matter particles interacting with nuclei (e.g. Weakly Interacting Massive Particles, WIMPs). However, there exists a large variety of different candidates for dark-matter particles. One of these candidates, the so-called dark photon, is a long-lived vector boson with a kinetic mixing to the standard-model photon. In this work we present the preliminary results of our search for dark photons. Using data from the direct dark matter search CRESST-II Phase 2 we can improve the existing constraints for the kinetic mixing for dark-photon masses between 0.3 and 0.5 keV/c2. In addition, we also present projected sensitivities for the next phases of the CRESST-III experiment showing great potential to improve the sensitivity for dark-photon masses below 1 keV.

  8. High-density ionization with an intense linear focus discharge

    International Nuclear Information System (INIS)

    Lee, T.N.

    1975-01-01

    Some experimental results obtained with a linear focus device are described. Measurements include plasma diagnostics made with fast photography, pinhole x-ray photography, and x-ray spectroscopy in the photon energy range of 6 to 35 0 keV. (MOW)

  9. Photonic Crystals: Physics and Technology

    CERN Document Server

    Sibilia, Concita; Marciniak, Marian; Szoplik, Tomasz

    2008-01-01

    The aim of the work is give an overview of the activity in the field of Photonic Crystal developed in the frame of COST P11 action . The main objective of the COST P11 action was to unify and coordinate national efforts aimed at studying linear and nonlinear optical interactions with Photonic Crystals (PCs), without neglecting an important aspect related to the material research as idea and methods of realizations of 3D PC, together with the development and implementation of measurement techniques for the experimental evaluation of their potential applications in different area, as for example telecommunication with novel optical fibers, lasers, nonlinear multi-functionality, display devices , opto-electronics, sensors. The book contain contributions from authors who gave their lecture at the Cost P11 Training School. Training School was held at the Warsaw University (2007) and National Institute of Telecommunications (May 23), Warsaw. It was attended by 23 students. The focus of the School was on the work of...

  10. Design and performance of the focusing DIRC detector

    Energy Technology Data Exchange (ETDEWEB)

    Dey, B. [University of California, Riverside, CA 92521 (United States); Borsato, M.; Arnaud, N. [Laboratoire de l' Accélérateur Linéaire, Centre Scientifique d' Orsay, F-91898 Orsay Cedex (France); Leith, D.W.G.S.; Nishimura, K. [SLAC National Accelerator Laboratory, Stanford, CA 94309 (United States); Roberts, D.A. [University of Maryland, College Park, MD 20742, USA. (United States); Ratcliff, B.N. [SLAC National Accelerator Laboratory, Stanford, CA 94309 (United States); Varner, G. [University of Hawaii, Honolulu, HI 96822, USA. (United States); Va' vra, J., E-mail: jjv@slac.stanford.edu [SLAC National Accelerator Laboratory, Stanford, CA 94309 (United States)

    2015-03-01

    We present the final results from a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC). This detector was designed as a full-scale prototype of the particle identification system for the SuperB experiment [1], and comprises 1/12 of the SuperB barrel azimuthal coverage, with partial photodetector and electronics implementation. The prototype was tested in the SLAC Cosmic Ray Telescope which provided 3D tracking of cosmic muons with an angular resolution of ~1.5 mrad, a position resolution of 4–5 mm, a start time resolution of 70 ps, and muon tracks above ~2 GeV tagged using an iron range stack. The fused silica focusing photon camera was coupled to a full-size BaBar DIRC bar box and was read out, over part of the full coverage, by 12 Hamamatsu H8500 multi-anode photomultipliers (MaPMTs) providing 768 pixels. We used waveform digitizing electronics to read out the MaPMTs. We give a detailed description of our data analysis methods and point out limitations on the present performance. We present results that demonstrate some basic performance characteristics of this design, including (a) single photon Cherenkov angle resolutions with and without chromatic corrections, (b) signal-to-noise (S/N) ratio between the Cherenkov peak and background, which primarily consists of ambiguities of the possible photon paths from emission along the track to a given pixel, (c) dTOP=TOP{sub measured} – TOP{sub expected} resolutions (with TOP being the photon Time-of-Propagation in fused silica), and (d) performance of the detector in the presence of high-rate backgrounds.

  11. MR angiography of the carotid arteries in 3 D TOF-technique with sagittal ''double-slab'' acquisition using a new head-neck coil

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Heller, M.

    1996-01-01

    Purpose: The aim of the study was to assess the value of MR angiography (MRA) in sagittal technique compared to DSA in the evaluation of carotid artery stenosis. Methods: 80 Carotid arteries in 40 symptomatic patients were prospectively studied with DSA and MRA. MRA was carried out by means of 3D time-of-flight technique with a FISP sequence (T E 6 ms/T R 80 ms, flip angle 25 , FOV 240x210 mm, matrix 157x256 mm, in-plane resolution 1.34x0.94 mm, partition thickness 1.32 mm, slab thickness 45 mm, acquisition time 7 min) using a new head-neck coil. Data acquisition was performed in sagittal orientation with the 'double-slab' technique. Imaging quality of the extracranial carotid arteries and correctness of quantification of stenosis was performed. Results: Imaging quality was good at the origin of the carotid arteries in 65%, at the bifurcation region in 98% and near the skull base in 81%. The agreement of DSA and MRA was 96% of the normal arteries (24/25), 90% of the severe stenoses (28/31) and 100% of the occluded arteries (9/9). Conclusion: MRA in sagittal 'double-slab' technique is a noninvasive technique allowing to detect normal arteries and candidates for surgery with high degree of certainity. (orig.) [de

  12. Photonic Hypercrystals

    Directory of Open Access Journals (Sweden)

    Evgenii E. Narimanov

    2014-10-01

    Full Text Available We introduce a new “universality class” of artificial optical media—photonic hypercrystals. These hyperbolic metamaterials, with periodic spatial variation of dielectric permittivity on subwavelength scale, combine the features of optical metamaterials and photonic crystals. In particular, surface waves supported by a hypercrystal possess the properties of both the optical Tamm states in photonic crystals and surface-plasmon polaritons at the metal-dielectric interface.

  13. Tests of perturbative quantum chromodynamics in photon-photon collisions

    International Nuclear Information System (INIS)

    Brodsky, S.J.

    1979-01-01

    The production of hadrons in the collision of two photons via the process e + e - → e + e - X can provide an ideal laboratory for testing many of the features of the photon's hadronic interactions, especially its short-distance aspects. That part of two-photon physics which is particularly relevant to tests of perturbative QCD is reviewed here. 6 figures

  14. Spinal curves and health: a systematic critical review of the epidemiological literature dealing with associations between sagittal spinal curves and health

    DEFF Research Database (Denmark)

    Christensen, Sanne Toftgaard; Hartvigsen, Jan

    2008-01-01

    The purposes of this study were to (1) determine whether sagittal spinal curves are associated with health in epidemiological studies, (2) estimate the strength of such associations, and (3) consider whether these relations are likely to be causal....

  15. Photonic crystals: towards nanoscale photonic devices

    National Research Council Canada - National Science Library

    Lourtioz, J.-M

    2005-01-01

    .... From this point of view, the emergence of photonic bandgap materials and photonic crystals at the end of the 1980s can be seen as a revenge to the benefit this time of optics and electromagnetism. In the same way as the periodicity of solid state crystals determines the energy bands and the conduction properties of electrons, the periodical structur...

  16. Photonic and plasmonic guided modes in graphene-silicon photonic crystals

    DEFF Research Database (Denmark)

    Gu, Tingyi; Andryieuski, Andrei; Hao, Yufeng

    2016-01-01

    We report the results of systematic studies of plasmonic and photonic guided modes in large-area single-layer graphene integrated into a nanostructured silicon substrate. The interaction of light with graphene and substrate photonic crystals can be classified in distinct regimes of plasmonic...... and photonic modes....

  17. Bose-Einstein condensation of photons in a 'white-wall' photon box

    International Nuclear Information System (INIS)

    Klaers, Jan; Schmitt, Julian; Vewinger, Frank; Weitz, Martin

    2011-01-01

    Bose-Einstein condensation, the macroscopic ground state occupation of a system of bosonic particles below a critical temperature, has been observed in cold atomic gases and solid-state physics quasiparticles. In contrast, photons do not show this phase transition usually, because in Planck's blackbody radiation the particle number is not conserved and at low temperature the photons disappear in the walls of the system. Here we report on the realization of a photon Bose-Einstein condensate in a dye-filled optical microcavity, which acts as a 'white-wall' photon box. The cavity mirrors provide a trapping potential and a non-vanishing effective photon mass, making the system formally equivalent to a two-dimensional gas of trapped massive bosons. Thermalization of the photon gas is reached in a number conserving way by multiple scattering off the dye molecules. Signatures for a BEC upon increased photon density are: a spectral distribution that shows Bose-Einstein distributed photon energies with a macroscopically populated peak on top of a broad thermal wing, the observed threshold of the phase transition showing the predicted absolute value and scaling with resonator geometry, and condensation appearing at the trap centre even for a spatially displaced pump spot.

  18. Bose-Einstein condensation of photons in a 'white-wall' photon box

    Science.gov (United States)

    Klärs, Jan; Schmitt, Julian; Vewinger, Frank; Weitz, Martin

    2011-01-01

    Bose-Einstein condensation, the macroscopic ground state occupation of a system of bosonic particles below a critical temperature, has been observed in cold atomic gases and solid-state physics quasiparticles. In contrast, photons do not show this phase transition usually, because in Planck's blackbody radiation the particle number is not conserved and at low temperature the photons disappear in the walls of the system. Here we report on the realization of a photon Bose-Einstein condensate in a dye-filled optical microcavity, which acts as a "white-wall" photon box. The cavity mirrors provide a trapping potential and a non-vanishing effective photon mass, making the system formally equivalent to a two-dimensional gas of trapped massive bosons. Thermalization of the photon gas is reached in a number conserving way by multiple scattering off the dye molecules. Signatures for a BEC upon increased photon density are: a spectral distribution that shows Bose-Einstein distributed photon energies with a macroscopically populated peak on top of a broad thermal wing, the observed threshold of the phase transition showing the predicted absolute value and scaling with resonator geometry, and condensation appearing at the trap centre even for a spatially displaced pump spot.

  19. Stabilisation of sagittal split advancement osteotomies with miniplates: a prospective, multicentre study with two-year follow-up. Part I. Clinical parameters.

    NARCIS (Netherlands)

    Borstlap, W.A.; Stoelinga, P.J.W.; Hoppenreijs, T.J.M.; Hof, M.A. van 't

    2004-01-01

    The principal aim of this study was to assess the postoperative stability of bilateral sagittal split osteotomies (BSSO) using two miniplates. Part I reports on the clinical results including treatment characteristics, nerve functions, TMJ function, occlusional relapse and patient satisfaction. This

  20. Silicon Microspheres Photonics

    International Nuclear Information System (INIS)

    Serpenguzel, A.

    2008-01-01

    Electrophotonic integrated circuits (EPICs), or alternatively, optoelectronic integrated circuit (OEICs) are the natural evolution of the microelectronic integrated circuit (IC) with the addition of photonic capabilities. Traditionally, the IC industry has been based on group IV silicon, whereas the photonics industry on group III-V semiconductors. However, silicon based photonic microdevices have been making strands in siliconizing photonics. Silicon microspheres with their high quality factor whispering gallery modes (WGMs), are ideal candidates for wavelength division multiplexing (WDM) applications in the standard near-infrared communication bands. In this work, we will discuss the possibility of using silicon microspheres for photonics applications in the near-infrared

  1. Photon correlation holography.

    Science.gov (United States)

    Naik, Dinesh N; Singh, Rakesh Kumar; Ezawa, Takahiro; Miyamoto, Yoko; Takeda, Mitsuo

    2011-01-17

    Unconventional holography called photon correlation holography is proposed and experimentally demonstrated. Using photon correlation, i.e. intensity correlation or fourth order correlation of optical field, a 3-D image of the object recorded in a hologram is reconstructed stochastically with illumination through a random phase screen. Two different schemes for realizing photon correlation holography are examined by numerical simulations, and the experiment was performed for one of the reconstruction schemes suitable for the experimental proof of the principle. The technique of photon correlation holography provides a new insight into how the information is embedded in the spatial as well as temporal correlation of photons in the stochastic pseudo thermal light.

  2. Quantum dot single-photon switches of resonant tunneling current for discriminating-photon-number detection.

    Science.gov (United States)

    Weng, Qianchun; An, Zhenghua; Zhang, Bo; Chen, Pingping; Chen, Xiaoshuang; Zhu, Ziqiang; Lu, Wei

    2015-03-23

    Low-noise single-photon detectors that can resolve photon numbers are used to monitor the operation of quantum gates in linear-optical quantum computation. Exactly 0, 1 or 2 photons registered in a detector should be distinguished especially in long-distance quantum communication and quantum computation. Here we demonstrate a photon-number-resolving detector based on quantum dot coupled resonant tunneling diodes (QD-cRTD). Individual quantum-dots (QDs) coupled closely with adjacent quantum well (QW) of resonant tunneling diode operate as photon-gated switches- which turn on (off) the RTD tunneling current when they trap photon-generated holes (recombine with injected electrons). Proposed electron-injecting operation fills electrons into coupled QDs which turn "photon-switches" to "OFF" state and make the detector ready for multiple-photons detection. With proper decision regions defined, 1-photon and 2-photon states are resolved in 4.2 K with excellent propabilities of accuracy of 90% and 98% respectively. Further, by identifying step-like photon responses, the photon-number-resolving capability is sustained to 77 K, making the detector a promising candidate for advanced quantum information applications where photon-number-states should be accurately distinguished.

  3. How does sagittal imbalance affect the appropriateness of surgical indications and selection of procedure in the treatment of degenerative scoliosis? Findings from the RAND/UCLA Appropriate Use Criteria study.

    Science.gov (United States)

    Daubs, Michael D; Brara, Harsimran S; Raaen, Laura B; Chen, Peggy Guey-Chi; Anderson, Ashaunta T; Asch, Steven M; Nuckols, Teryl K

    2018-05-01

    Degenerative lumbar scoliosis (DLS) is often associated with sagittal imbalance, which may affect patients' health outcomes before and after surgery. The appropriateness of surgery and preferred operative approaches has not been examined in detail for patients with DLS and sagittal imbalance. The goals of this article were to describe what is currently known about the relationship between sagittal imbalance and health outcomes among patients with DLS and to determine how indications for surgery in patients with DLS differ when sagittal imbalance is present. This study included a literature review and an expert panel using the RAND/University of California at Los Angeles (UCLA) Appropriateness Method. To develop appropriate use criteria for DLS, researchers at the RAND Corporation recently employed the RAND/UCLA Appropriateness Method, which involves a systematic review of the literature and multidisciplinary expert panel process. Experts reviewed a synopsis of published literature and rated the appropriateness of five common operative approaches for 260 different clinical scenarios. In the present work, we updated the literature review and compared panelists' ratings in scenarios where imbalance was present versus absent. This work was funded by the Collaborative Spine Research Foundation, a group of surgical specialty societies and device manufacturers. On the basis of 13 eligible studies that examined sagittal imbalance and outcomes in patients with DLS, imbalance was associated with worse functional status in the absence of surgery and worse symptoms and complications postoperatively. Panelists' ratings demonstrated a consistent pattern across the diverse clinical scenarios. In general, when imbalance was present, surgery was more likely to be appropriate or necessary, including in some situations where surgery would otherwise be inappropriate. For patients with moderate to severe symptoms and imbalance, a deformity correction procedure was usually appropriate

  4. Subjective and objective image qualities: a comparison of sagittal T2 weighted spin-echo and turbo-spin-eco sequences in magnetic resonance imaging of the spine by use of a subjective ranking system

    Energy Technology Data Exchange (ETDEWEB)

    Goerres, G. [Institut fuer diagnostische Radiologie, Departement Radiologie, Universitaetskliniken, Kantonsspital Basel (Switzerland); Mader, I. [Radiologische Gemeinschaftspraxis Dres. Siems, Grossmann, Bayreuth (Germany); Proske, M. [Klinikum Rosenheim (Germany). Inst. fuer Diagnostische Radiologie

    1998-12-31

    We evaluated the subjective image impression of two different magnetic resonance (MR) sequences by using a subjective ranking system. This ranking system was based on 20 criteria describing several tissue characteristics such as the signal intensity of normal anatomical structures and the changes of signal intensities and shape of lesions as well as artefacts. MR of the vertebral spine was performed in 48 female and 52 male patients (mean age 44.8 years) referred consecutively for investigation of a back problem. Ninety-six pathologies were found in 82 patients. Sagittal and axial T1 weighted spin-echo before and after administration of Gadolinium (Gd-DOTA), and sagittal T2 weighted spin-echo (T2wSE) and Turbo-spin-echo (TSE) sequences were performed by means of surface coils. Using the subjective ranking system the sagittal T2wSE and sagittal TSE were compared. Both sequences were suitable for identification of normal anatomy and pathologic changes and there was no trend for increased detection of disease by one imaging sequence over the other. We found that sagittal TSE sequences can replace sagittal T2wSE sequences in spinal MR and that artefacts at the cervical and lumbar spine are less frequent using TSE, thus confirming previous studies. In this study, our ranking system reveiled, that there are differences between the subjective judgement of image qualities and objective measurement of SNR. However, this approach may not be helpful to compare two different MR sequences as it is limited to the anatomical area investigated and is time consuming. The subjective image impression, i.e. the quality of images, may not always be represented by physical parameters such as a signal-to-noise ratio (SNR), radiologists should try to define influences of image quality also by subjective parameters. (orig.)

  5. Collective phenomena in photonic, plasmonic and hybrid structures.

    Science.gov (United States)

    Boriskina, Svetlana V; Povinelli, Michelle; Astratov, Vasily N; Zayats, Anatoly V; Podolskiy, Viktor A

    2011-10-24

    Preface to a focus issue of invited articles that review recent progress in studying the fundamental physics of collective phenomena associated with coupling of confined photonic, plasmonic, electronic and phononic states and in exploiting these phenomena to engineer novel devices for light generation, optical sensing, and information processing. © 2011 Optical Society of America

  6. Active Photonic Crystal Waveguides

    DEFF Research Database (Denmark)

    Ek, Sara

    This thesis deals with the fabrication and characterization of active photonic crystal waveguides, realized in III-V semiconductor material with embedded active layers. The platform offering active photonic crystal waveguides has many potential applications. One of these is a compact photonic...... due to photonic crystal dispersion. The observations are explained by the enhancement of net gain by light slow down. Another application based on active photonic crystal waveguides is micro lasers. Measurements on quantum dot micro laser cavities with different mirror configurations and photonic...

  7. Two-Dimensional Photonic Crystals for Sensitive Microscale Chemical and Biochemical Sensing

    Science.gov (United States)

    Miller, Benjamin L.

    2015-01-01

    Photonic crystals – optical devices able to respond to changes in the refractive index of a small volume of space – are an emerging class of label-free chemical-and bio-sensors. This review focuses on one class of photonic crystal, in which light is confined to a patterned planar material layer of sub-wavelength thickness. These devices are small (on the order of tens to 100s of microns square), suitable for incorporation into lab-on-a-chip systems, and in theory can provide exceptional sensitivity. We introduce the defining characteristics and basic operation of two-dimensional photonic crystal sensors, describe variations of their basic design geometry, and summarize reported detection results from chemical and biological sensing experiments. PMID:25563402

  8. Photonic crystal light source

    Science.gov (United States)

    Fleming, James G [Albuquerque, NM; Lin, Shawn-Yu [Albuquerque, NM; Bur, James A [Corrales, NM

    2004-07-27

    A light source is provided by a photonic crystal having an enhanced photonic density-of-states over a band of frequencies and wherein at least one of the dielectric materials of the photonic crystal has a complex dielectric constant, thereby producing enhanced light emission at the band of frequencies when the photonic crystal is heated. The dielectric material can be a metal, such as tungsten. The spectral properties of the light source can be easily tuned by modification of the photonic crystal structure and materials. The photonic crystal light source can be heated electrically or other heating means. The light source can further include additional photonic crystals that exhibit enhanced light emission at a different band of frequencies to provide for color mixing. The photonic crystal light source may have applications in optical telecommunications, information displays, energy conversion, sensors, and other optical applications.

  9. Approaching the Ultimate Limits of Communication Efficiency with a Photon-Counting Detector

    Science.gov (United States)

    Erkmen, Baris; Moision, Bruce; Dolinar, Samuel J.; Birnbaum, Kevin M.; Divsalar, Dariush

    2012-01-01

    Coherent states achieve the Holevo capacity of a pure-loss channel when paired with an optimal measurement, but a physical realization of this measurement is as of yet unknown, and it is also likely to be of high complexity. In this paper, we focus on the photon-counting measurement and study the photon and dimensional efficiencies attainable with modulations over classical- and nonclassical-state alphabets. We first review the state-of-the-art coherent on-off-keying (OOK) with a photoncounting measurement, illustrating its asymptotic inefficiency relative to the Holevo limit. We show that a commonly made Poisson approximation in thermal noise leads to unbounded photon information efficiencies, violating the conjectured Holevo limit. We analyze two binary-modulation architectures that improve upon the dimensional versus photon efficiency tradeoff achievable with conventional OOK. We show that at high photon efficiency these architectures achieve an efficiency tradeoff that differs from the best possible tradeoff--determined by the Holevo capacity--by only a constant factor. The first architecture we analyze is a coherent-state transmitter that relies on feedback from the receiver to control the transmitted energy. The second architecture uses a single-photon number-state source.

  10. Positronium-photon and photon-positronium quantum transitions in strong magnetic fields

    International Nuclear Information System (INIS)

    Leinson, L.B.; Oraevskii, V.N.; Radio-Wave Propagation, Academy of Sciences of the USSR)

    1985-01-01

    The wave functions and energy levels of bound electron-positron pairs in a strong magnetic field H>>α 2 H 0 , where H 0 = m 2 0 c 3 /eh = 4.4 x 10 13 G and α = e 2 /hc, are found in the nonrelativistic approximation. The probabilities of one-photon annihilation of positronium and of the inverse transition from a resonance photon to a positronium atom are calculated. It is shown that in a sufficiently strong magnetic field H∼H 0 , when the probability of one-photon annihilation is considerably greater than the probability of two-photon annihilation of positronium, the lifetime of the decay photon with respect to the inverse transformation to a positronium atom is so small that the decay photon cannot propagate freely in the magnetic field. Therefore, the lifetime of the positronium atom in the case H∼H 0 is determined by the two-photon decay. The possibility of the decay γ→γ 1 +γ 2 via intermediate positronium states in a magnetic field with curved field lines is discussed

  11. Photon wave function

    OpenAIRE

    Bialynicki-Birula, Iwo

    2005-01-01

    Photon wave function is a controversial concept. Controversies stem from the fact that photon wave functions can not have all the properties of the Schroedinger wave functions of nonrelativistic wave mechanics. Insistence on those properties that, owing to peculiarities of photon dynamics, cannot be rendered, led some physicists to the extreme opinion that the photon wave function does not exist. I reject such a fundamentalist point of view in favor of a more pragmatic approach. In my view, t...

  12. Single-photon imaging

    CERN Document Server

    Seitz, Peter

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncoooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist´s view from different domains to the forthcoming “single-photon imaging” revolution. The various aspects of single-photon imaging are treated by internati...

  13. Advances in the FDTD design and modeling of nano- and bio-photonics applications

    DEFF Research Database (Denmark)

    Tanev, Stoyan; Tuchin, Valery; Cheben, Pavel

    2011-01-01

    In this paper we focus on the discussion of two recent unique applications of the finite-difference time-domain (FDTD) simulation method to the design and modeling of advanced nano- and bio-photonic problems. The approach that is adopted here focuses on the potential of the FDTD methodology...

  14. Os acromiale: evaluation of markers for identification on sagittal and coronal oblique MR images

    Energy Technology Data Exchange (ETDEWEB)

    Uri, D.S. [University of Michigan, Dept. of Radiology, Ann Arbor, MI (United States)]|[Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia (United States); Kneeland, J.B. [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia (United States); Herzog, R. [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia (United States)

    1997-01-01

    An os acromiale is a developmental abnormality of ossification involving the anterior acromion which may contribute to impingement and rotator cuff disease. When axial MR sections do not include the acromioclavicular joint, the diagnosis of this often subtle abnormality will rest on its recognition on oblique coronal and sagittal images where it mimics the acromioclavicular joint. The identification of this anomaly is important as it frequently alters the type of surgical procedure utilized in symptomatic patients. We evaluate several imaging features which may be used to diagnose an os acromiale in these cases. (orig.). With 5 figs.

  15. Os acromiale: evaluation of markers for identification on sagittal and coronal oblique MR images

    International Nuclear Information System (INIS)

    Uri, D.S.; Kneeland, J.B.; Herzog, R.

    1997-01-01

    An os acromiale is a developmental abnormality of ossification involving the anterior acromion which may contribute to impingement and rotator cuff disease. When axial MR sections do not include the acromioclavicular joint, the diagnosis of this often subtle abnormality will rest on its recognition on oblique coronal and sagittal images where it mimics the acromioclavicular joint. The identification of this anomaly is important as it frequently alters the type of surgical procedure utilized in symptomatic patients. We evaluate several imaging features which may be used to diagnose an os acromiale in these cases. (orig.). With 5 figs

  16. EDITORIAL: The next photonic revolution The next photonic revolution

    Science.gov (United States)

    Zheludev, Nikolay I.

    2009-11-01

    This special section on Nanophotonics and Metamaterials is a follow-up to the second European Topical Meeting of the NANOMETA series of meetings (see www.nanometa.org) which took place on 5-8 January 2009, in Seefeld, Austria. The main idea of the first NANOMETA meeting held in 2007 was to bring together the mature community of microwave electrical engineers with the emerging community of photonics researchers interested in the physics of light coupled to nanostructures. In recent years the research landscape has shifted dramatically. A wider proliferation of nanofabrication techniques such as electron beam lithography, nanoimprint and focused ion beam milling, diagnostics techniques such as near-field scanning imaging, cathodoluminescence with nanoscale resolution and micro-spectrometry, and the availability of affordable broadband and ultrafast optical sources, have moved the research focus of the NANOMETA community to the optical domain. Quite naturally the ideas of the nonlinearity of materials and the coherency of light in the nanoscale realm have been widely discussed. Driven by the dream of untapped device and material functionality, nonlinear and switchable nanophotonic devices and photonic metamaterials, along with the concept of tailoring the electromagnetic space with metamaterials, appear to be the main avenues along which the subject will develop in the coming years. Indeed, in the last 20 years photonics has played a key role in creating the world as we know it, with enormous beneficial social impact worldwide. It is impossible to imagine modern society without the globe-spanning broadband internet and mobile telephony made possible by the implementation of optical fibre core networks, optical disc data storage (underpinned by the development of compact semiconductor lasers), modern image display technologies and laser-assisted manufacturing. We now anticipate that the next photonic revolution will continue to grow, explosively fuelled by a new

  17. The significance of faint visualization of the superior sagittal sinus in brain scintigraphy for the diagnosis of brain death

    International Nuclear Information System (INIS)

    Bisset, R.; Sfakianakis, G.; Ihmedian, I.; Holzman, B.; Curless, R.; Serafini, A.

    1985-01-01

    Brain death is associated with cessation of blood flow to the brain. Tc-99m brain flow studies are used as a laboratory confirmatory test for the establishment of the diagnosis of brain death. Criteria for the diagnosis of cessation of blood flow to the brain are 1) visualization of carotid artery activity in the neck of the patient and 2) no visualization of activity in the distribution of the anterior and middle cerebral arteries. The authors noticed that in a significant number of patients, although there was no visualization of arterial blood flow to the brain the static images demonstrated faint accumulation of activity in the region of the superior sagittal sinus (SSS). In a four year period 212 brain flow studies were performed in 154 patients for diagnosis of brain death; of them 137 studies (65%) showed no evidence of arterial flow. In 103 out of the 137 studies (75%) there was no visualization of the SSS; in the remaining 34 studies (3l patients) however three patterns of faint activity attributed to partial and or faint visualization of the SSS could be recognized at the midline of the immediate anterior static view: a) linear from the cranial vault floor up b) disk shaped at the apex of the vault and c) disk shaped at the apex tailing caudad. All of the 3l patients in this group satisfied brain death criteria within four days of the last study which showed faint visualization of the superior sagittal sinus. The authors conclude that even in the presence of a faint visualization of the superior sagittal sinus on static post brain flow scintigraphy, the diagnosis of cessation of blood flow to the brain can be made if there is no evidence of arterial blood flow

  18. Effect of trunk sagittal attitude on shoulder, thorax and pelvis three-dimensional kinematics in able-bodied subjects during gait.

    Directory of Open Access Journals (Sweden)

    Alberto Leardini

    Full Text Available It has been shown that an original attitude in forward or backward inclination of the trunk is maintained at gait initiation and during locomotion, and that this affects lower limb loading patterns. However, no studies have shown the extent to which shoulder, thorax and pelvis three-dimensional kinematics are modified during gait due to this sagittal inclination attitude. Thirty young healthy volunteers were analyzed during level walking with video-based motion analysis. Reflecting markers were mounted on anatomical landmarks to form a two-marker shoulder line segment, and a four-marker thorax and pelvis segments. Absolute and relative spatial rotations were calculated, for a total of 11 degrees of freedom. The subjects were divided into two groups of 15 according to the median of mean thorax inclination angle over the gait cycle. Preliminary MANOVA analysis assessed whether gender was an independent variable. Then two-factor nested ANOVA was used to test the possible effect of thorax inclination on body segments, planes of motion and gait periods, separately. There was no significant difference in all anthropometric and spatio-temporal parameters between the two groups, except for subject mass. The three-dimensional kinematics of the thorax and pelvis were not affected by gender. Nested ANOVA revealed group effect in all segment rotations apart those at the pelvis, in the sagittal and frontal planes, and at the push-off. Attitudes in sagittal thorax inclination altered trunk segments kinematics during gait. Subjects with a backward thorax showed less thorax-to-pelvis motion, but more shoulder-to-thorax and thorax-to-laboratory motion, less motion in flexion/extension and in lateral bending, and also less motion during push-off. This contributes to the understanding of forward propulsion and sideways load transfer mechanisms, fundamental for the maintenance of balance and the risk of falling.

  19. Electrons and photons in periodic structures

    DEFF Research Database (Denmark)

    Pedersen, Jesper Goor

    . In particular, the modulation leads to the emergence of band gaps, which are accompanied by a strongly modified density of states near and within the band gap. The main focus is on two applications of such modified densities of states. Firstly, the intentional introduction of defects in an otherwise perfectly...... periodic modulation of an electron gas leads to the emergence of localized defect states with energies within the band gap, where no propagating modes exist. Secondly, the divergence of the photonic density of states near a photonic band gap leads to strongly modified light-matter interactions, which has...... of the density of states near the band gap edge. Using a perturbative approach, we demonstrate certain limits of the attainable slow down factors due to broadening of electromagnetic modes. We discuss the effect of damping due to a finite conductivity as well as structural disorder, and provide a common...

  20. Advanced photon counting applications, methods, instrumentation

    CERN Document Server

    Kapusta, Peter; Erdmann, Rainer

    2015-01-01

    This volume focuses on Time-Correlated Single Photon Counting (TCSPC), a powerful tool allowing luminescence lifetime measurements to be made with high temporal resolution, even on single molecules. Combining spectrum and lifetime provides a "fingerprint" for identifying such molecules in the presence of a background. Used together with confocal detection, this permits single-molecule spectroscopy and microscopy in addition to ensemble measurements, opening up an enormous range of hot life science applications such as fluorescence lifetime imaging (FLIM) and measurement of Förster Resonant Energy Transfer (FRET) for the investigation of protein folding and interaction. Several technology-related chapters present both the basics and current state-of-the-art, in particular of TCSPC electronics, photon detectors and lasers. The remaining chapters cover a broad range of applications and methodologies for experiments and data analysis, including the life sciences, defect centers in diamonds, super-resolution micr...

  1. Plasmonic and Photonic Modes Excitation in Graphene on Silicon Photonic Crystal Membrane

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Gu, Tingyi; Hao, Yufeng

    . Being deposited on a silicon photonic crystal membrane graphene serves as a highly promising system for modern optoelectronics with rich variety of possible regimes. Depending on the relation between the photonic crystal lattice constant and wavelengths (plasmonic, photonic and free-space) we identify...... characterization. Measured data are well correlated with the numerical analysis. Combined graphene – silicon photonic crystal membranes can find applications for infrared absorbers, modulators, filters, sensors and photodetectors....... four different interaction schemes. We refer to them as metamaterial, plasmonic, photonic and diffraction grating regimes based on the principle character of light interactions with the graphene deposited on the Si photonic crystal membrane. The optimal configurations for resonant excitation of modes...

  2. Two-Photon Fluorescence Microscope for Microgravity Research

    Science.gov (United States)

    Fischer, David G.; Zimmerli, Gregory A.; Asipauskas, Marius

    2005-01-01

    A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the

  3. Dorsal buccal mucosal graft urethroplasty by a ventral sagittal urethrotomy and minimal-access perineal approach for anterior urethral stricture.

    Science.gov (United States)

    Gupta, N P; Ansari, M S; Dogra, P N; Tandon, S

    2004-06-01

    To present the technique of dorsal buccal mucosal graft urethroplasty through a ventral sagittal urethrotomy and minimal access perineal approach for anterior urethral stricture. From July 2001 to December 2002, 12 patients with a long anterior urethral stricture had the anterior urethra reconstructed, using a one-stage urethroplasty with a dorsal onlay buccal mucosal graft through a ventral sagittal urethrotomy. The urethra was approached via a small perineal incision irrespective of the site and length of the stricture. The penis was everted through the perineal wound. No urethral dissection was used on laterally or dorsally, so as not to jeopardize the blood supply. The mean (range) length of the stricture was 5 (3-16) cm and the follow-up 12 (10-16) months. The results were good in 11 of the 12 patients. One patient developed a stricture at the proximal anastomotic site and required optical internal urethrotomy. Dorsal buccal mucosal graft urethroplasty via a minimal access perineal approach is a simple technique with a good surgical outcome; it does not require urethral dissection and mobilization and hence preserves the blood supply.

  4. Grading system for migrated lumbar disc herniation on sagittal magnetic resonance imaging. An agreement study

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Y.; Jeong, T.S. [Gachon University Gil Medical Center, Department of Neurosurgery, Incheon (Korea, Republic of); Lim, T.; Jeon, J.Y. [Gachon University Gil Medical Center, Department of Radiology, Incheon (Korea, Republic of)

    2018-01-15

    Migrated lumbar disc herniations (LDHs) in the sagittal plane are common. Disc migration grading can be applied as a useful measurement tool in the diagnosis, treatment, and outcome evaluation of migrated LDH. No study has evaluated the reliability of migrated LDH grading. We evaluated the reliability and functionality of the current magnetic resonance imaging (MRI) grading system for migrated LDH. We assessed a six-level grading system developed based on sagittal MRI and graded according to the direction (rostral and caudal) and degree (low, high, and very high) of disc migration. One-hundred and one migrated LDHs treated with minimally invasive endoscopic discectomy were analyzed independently by two experienced radiologists. Intraobserver and interobserver agreements were assessed by kappa statistics. The most common migrated LDH grade was grade 4 (30.94%; caudal, low-grade migration). Rostral and caudal migrations were more common in the upper and lower lumbar levels, respectively. Interobserver agreement in the grading of migrated LDH was good at both the first (kappa = 0.737) and second assessment (kappa = 0.657). The intraobserver agreement for reader 1 was very good (kappa = 0.827) and for reader 2 was good (kappa = 0.620). The current grading system for migrated LDH was found to be reliable and functional with good interobserver and intraobserver agreement. It may be useful in the interpretation of disc migration patterns and outcomes of various minimally invasive surgical procedures. (orig.)

  5. Increased detection rate of syringomyelia by whole spine sagittal magnetic resonance images: Based on the data from military conscription of Korean young males

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok; Oh, Chang Hyun [Seoul Regional Military Manpower Administration, Seoul (Korea, Republic of); Yoon, Seung Hwan; Park, Hyeong Chun; Park, Chong Oon; Kim, Yeo Ju [Inha Univ. Hospital/College of Medicine/Inha Univ., Incheon (Korea, Republic of)

    2012-09-15

    We compared the detection rate of syringomyelia according to the type of magnetic resonance (MR) images among the Korean military conscription. Among the total of 238910 examinees (males aged 18 to 32 years old) from January 2008 to December 2011, the examinees with conventional single lesion MR images (cervical, thoracic, and lumbar) with and without whole spine sagittal T2 weighted MR images (WSST2I) totaled 1206 cases, and syringomyelia was observed in 24 cases. The detection rate of syringomyelia according to the MR protocol (the presence of WSST2I or not) was done through analysis by annually and the clinical characters of syringomyelia was reviewed. The estimated prevalence of syringomyelia was approximately 10.0 cases per 100000 people. The detection rate was increased annually when the WSST2I proportion was increased (from 3.4 to 14.9 cases per 100000 persons, r = 0.939, p = 0.018). Clinical character of syringomyelia was ambiguous with other spinal diseases. The most affected spinal level was C5 to C7 (83%), and most cases were non communicating syringomyelia with benign central canal widening (79%). Whole spine sagittal MR image is useful to detect coexisting spinal diseases such as syringomyelia, and most syringomyelia in young males was benign hydromyelia. A whole spine sagittal MR image is recommended to increase the detection of syringomyelia.

  6. Dark-photon search using data from CRESST-II Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    Angloher, G.; Bauer, P.; Iachellini, N.F.; Hauff, D.; Kiefer, M.; Mancuso, M.; Petricca, F.; Proebst, F.; Seidel, W.; Stodolsky, L.; Strauss, R.; Tanzke, A.; Wuestrich, M. [Max-Planck-Institut fuer Physik, Munich (Germany); Bento, A. [Max-Planck-Institut fuer Physik, Munich (Germany); Universidade de Coimbra, Departamento de Fisica, Coimbra (Portugal); Bucci, C.; Gorla, P.; Pagliarone, C. [INFN, Laboratori Nazionali del Gran Sasso, Assergi (Italy); Canonica, L. [INFN, Laboratori Nazionali del Gran Sasso, Assergi (Italy); Massachusetts Institute of Technology, Cambridge, MA (United States); Defay, X.; Feilitzsch, F. v.; Lanfranchi, J.C.; Muenster, A.; Potzel, W.; Schoenert, S.; Thi, H.H.T.; Ulrich, A.; Wawoczny, S.; Willers, M.; Zoeller, A. [Technische Universitaet Muenchen, Physik-Department and Excellence Cluster Universe, Garching (Germany); Erb, A. [Technische Universitaet Muenchen, Physik-Department and Excellence Cluster Universe, Garching (Germany); Walther-Meissner-Institut fuer Tieftemperaturforschung, Garching (Germany); Guetlein, A.; Kluck, H.; Puig, R.; Schieck, J.; Tuerkoglu, C. [Institut fuer Hochenergiephysik der Oesterreichischen Akademie der Wissenschaften, Vienna (Austria); Atominstitut, Vienna University of Technology, Vienna (Austria); Jochum, J.; Loebell, J.; Strandhagen, C.; Uffinger, M.; Usherov, I. [Eberhard-Karls-Universitaet Tuebingen, Tuebingen (Germany); Kraus, H. [University of Oxford, Department of Physics, Oxford (United Kingdom); Reindl, F. [Max-Planck-Institut fuer Physik, Munich (Germany); INFN-Sezione di Roma, Rome (Italy); Schaeffner, K. [INFN, Laboratori Nazionali del Gran Sasso, Assergi (Italy); GSSI-Gran Sasso Science Institute, L' Aquila (Italy)

    2017-05-15

    Identifying the nature and origin of dark matter is one of the major challenges for modern astro and particle physics. Direct dark-matter searches aim at an observation of dark-matter particles interacting within detectors. The focus of several such searches is on interactions with nuclei as provided e.g. by weakly interacting massive particles. However, there is a variety of dark-matter candidates favoring interactions with electrons rather than with nuclei. One example are dark photons, i.e., long-lived vector particles with a kinetic mixing to standard-model photons. In this work we present constraints on this kinetic mixing based on data from CRESST-II Phase 2 corresponding to an exposure before cuts of 52 kg-days. These constraints improve the existing ones for dark-photon masses between 0.3 and 0.7 keV/c{sup 2}. (orig.)

  7. Enhanced linear photonic nanojet generated by core-shell optical microfibers

    Science.gov (United States)

    Liu, Cheng-Yang; Yen, Tzu-Ping; Chen, Chien-Wen

    2017-05-01

    The generation of linear photonic nanojet using core-shell optical microfiber is demonstrated numerically and experimentally in the visible light region. The power flow patterns for the core-shell optical microfiber are calculated by using the finite-difference time-domain method. The focusing properties of linear photonic nanojet are evaluated in terms of length and width along propagation and transversal directions. In experiment, the silica optical fiber is etched chemically down to 6 μm diameter and coated with metallic thin film by using glancing angle deposition. We show that the linear photonic nanojet is enhanced clearly by metallic shell due to surface plasmon polaritons. The large-area superresolution imaging can be performed by using a core-shell optical microfiber in the far-field system. The potential applications of this core-shell optical microfiber include micro-fluidics and nano-structure measurements.

  8. Spin-photon interface and spin-controlled photon switching in a nanobeam waveguide

    DEFF Research Database (Denmark)

    Javadi, Alisa; Ding, Dapeng; Appel, Martin Hayhurst

    2018-01-01

    Access to the electron spin is at the heart of many protocols for integrated and distributed quantum-information processing [1-4]. For instance, interfacing the spin-state of an electron and a photon can be utilized to perform quantum gates between photons [2,5] or to entangle remote spin states [6......-9]. Ultimately, a quantum network of entangled spins constitutes a new paradigm in quantum optics [1]. Towards this goal, an integrated spin-photon interface would be a major leap forward. Here we demonstrate an efficient and optically programmable interface between the spin of an electron in a quantum dot...... and photons in a nanophotonic waveguide. The spin can be deterministically prepared with a fidelity of 96\\%. Subsequently the system is used to implement a "single-spin photonic switch", where the spin state of the electron directs the flow of photons through the waveguide. The spin-photon interface may...

  9. Graphene-based photonic crystal

    International Nuclear Information System (INIS)

    Berman, Oleg L.; Boyko, Vladimir S.; Kezerashvili, Roman Ya.; Kolesnikov, Anton A.; Lozovik, Yurii E.

    2010-01-01

    A novel type of photonic crystal formed by embedding a periodic array of constituent stacks of alternating graphene and dielectric discs into a background dielectric medium is proposed. The photonic band structure and transmittance of such photonic crystal are calculated. The graphene-based photonic crystals can be used effectively as the frequency filters and waveguides for the far infrared region of electromagnetic spectrum. Due to substantial suppression of absorption of low-frequency radiation in doped graphene the damping and skin effect in the photonic crystal are also suppressed. The advantages of the graphene-based photonic crystal are discussed.

  10. Robust photonic differentiator employing slow light effect in photonic crystal waveguide

    DEFF Research Database (Denmark)

    Yan, Siqi; Cheng, Ziwei; Frandsen, Lars Hagedorn

    2017-01-01

    A robust photonic DIFF exploiting the slow light effect in a photonic crystal waveguide is proposed and experimentally demonstrated. Input Gaussian pulses with full-width halfmaximums ranging from 2.7 ps to 81.4 ps can be accurately differentiated.......A robust photonic DIFF exploiting the slow light effect in a photonic crystal waveguide is proposed and experimentally demonstrated. Input Gaussian pulses with full-width halfmaximums ranging from 2.7 ps to 81.4 ps can be accurately differentiated....

  11. Exclusive Channels in Photon-Photon Collisions at LEP

    OpenAIRE

    Braccini, Saverio

    2002-01-01

    The study of exclusive channels in photon-photon collisions at e+e- colliders allows to investigate the structure and the properties of hadrons in a very clean experimental environment. A concise review of the most recent results obtained at LEP is presented.

  12. Single-photon imaging

    International Nuclear Information System (INIS)

    Seitz, Peter; Theuwissen, Albert J.P.

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist's view from different domains to the forthcoming ''single-photon imaging'' revolution. The various aspects of single-photon imaging are treated by internationally renowned, leading scientists and technologists who have all pioneered their respective fields. (orig.)

  13. Modification of equivalent photon approximation (EPA) for resolved photon processes

    International Nuclear Information System (INIS)

    Drees, M.; Godbole, R.M.

    1995-05-01

    The authors propose a modification of the equivalent photon approximation (EPA) for processes which involve the parton content of the photon, to take into account the suppression of the photonic parton fluxes due to the virtuality of the photon. They present simple, physically motivated ansaetze to model this suppression and show that even though the parton content of the electron no longer factorizes into an electron flux function and photon structure function, it is still possible to express it as a single integral. They also show that for the TRISTAN (transposable ring intersecting storage accelerators in Nippon) experiments its effects can be numerically of the same size as that of the NLO corrections. Further, it is discussed a possible measurements at HERA (hadron electron ring an large), which can be provide an experimental handle on the effect the authors model through their ansaetze

  14. Amplified Photon Upconversion by Photonic Shell of Cholesteric Liquid Crystals.

    Science.gov (United States)

    Kang, Ji-Hwan; Kim, Shin-Hyun; Fernandez-Nieves, Alberto; Reichmanis, Elsa

    2017-04-26

    As an effective platform to exploit triplet-triplet-annihilation-based photon upconversion (TTA-UC), microcapsules composed of a fluidic UC core and photonic shell are microfluidically prepared using a triple emulsion as the template. The photonic shell consists of cholesteric liquid crystals (CLCs) with a periodic helical structure, exhibiting a photonic band gap. Combined with planar anchoring at the boundaries, the shell serves as a resonance cavity for TTA-UC emission and enables spectral tuning of the UC under low-power-density excitation. The CLC shell can be stabilized by introducing a polymerizable mesogen in the LC host. Because of the microcapsule spherical symmetry, spontaneous emission of the delayed fluorescence is omnidirectionally amplified at the edge of the stop band. These results demonstrate the range of opportunities provided by TTA-UC systems for the future design of low-threshold photonic devices.

  15. Influence of a variation in the position of the arms on the sagittal connection of the gravity line with the spinal structures.

    Science.gov (United States)

    Legaye, Jean; Duval-Beaupere, Ginette

    2017-11-01

    To evaluate the influence of the position of the arms on the location of the body's gravity line. The sagittal balance of the pelvi-spinal unit is organized so that the gravity line is localized in a way that limits the mechanical loads and the muscle efforts. This position of the gravity line was analyzed in vivo, in standing position, the arms dangling, by the barycentremeter, a gamma rays scanner. Then, several teams had the same purpose but using a force platform combined with radiographies. Their results differed significantly among themselves and with the data of the barycentremetry. However, in these studies, the positions of the arms varied noticeably, either slightly bent forwards on a support, or the fingers on the clavicles or on the cheeks. We estimated, for each varied posture of the arms, the sagittal coordinates of the masses of the upper limbs and their influence on the anatomical position of the gravity line of the whole body. Using a simple equation and the data of the barycentremeter, we observed that the variations in the location of the gravity line were proportionally connected to the changes of the sagittal position of the mass of the upper limbs induced by the various positions of the arms. We conclude in a validation of the data of the barycentremeter, as well as of the data obtained by the force platforms as long as the artifact of the position of the arms is taken into account.

  16. REPRODUCIBILITY AND EQUIVALENCE OF COBBMETER APPLICATION IN THE SAGITTAL EVALUATION OF THE SPINE

    Directory of Open Access Journals (Sweden)

    Luis Marchi

    Full Text Available ABSTRACT Objective: This study aims to evaluate the reliability and equivalency of using the Cobbmeter application for iPhone compared to the manual measurement method in the analysis of the sagittal spinal alignment. Methods: Cross-sectional, prospective, single-center study that had 20 panoramic radiographs of the spine in lateral view, in a neutral standing position, analyzed blindly and randomly by three independent examiners in three different times. The parameters were pelvic incidence (PI, pelvic tilt (PT and lumbar lordosis (LL. The statistical analysis was performed to measure the intraclass correlation coefficient (ICC between the two measurement methods, in addition to measuring the intra and inter-evaluators reliability. Results: For reproducibility analysis, the intra-evaluators ICC using the application resulted in a Kappa (K of 0.975 for the evaluation of pelvic incidence (PI evaluation. For pelvic tilt (PT, the K value obtained was 0.981 and the K measured for lumbar lordosis (LL analysis was 0.987. The inter-evaluators evaluation of reproducibility using the application resulted in a K value of 0.917 for PI, 0.930 for PT and 0.951 for LL. For the assessment of equivalency of methods, comparing the application to the standard method, with a goniometer and dermographic pencil, the K value found for PI was 0.873, for PV was 0.939 and for LL was 0.914. All values were significant (p<0.001 against the null hypothesis. Conclusion: This smartphone application is a valid and reliable instrument for measuring the angle involved in the sagittal balance of the spine. Furthermore, the results show that its applicability is not inferior to the manual method with goniometer and dermographic pencil.

  17. Quantum photonics with quantum dots in photonic wires

    DEFF Research Database (Denmark)

    Munsch, Mathieu; Kuhlmann, Andreas; Cadeddu, Davide

    2016-01-01

    We present results from the spectroscopy of a single quantum dot in a photonic wire. The device presents a high photon extraction efficiency, and strong hybrid coupling to mechanical modes. We use resonance fluorescence to probe the emitter’s properties with the highest sensitivity. Weperform...

  18. Illuminating RHIC matter with the multi-purpose direct photon

    International Nuclear Information System (INIS)

    Frantz, Justin

    2007-01-01

    In the RHIC era, the use of direct photon physics to probe heavy ion collisions has developed beyond its original scope. I make evaluations of the current state of several measurements by RHIC experiments and their associated physics implications, with a focus on their current and desired precision. At low p T , thermal photon theory is still not well constrained by the data, but improvements are on the way. At higher p T , we have been able to gain important insights, now with regards to the proposed 'jet-medium' photon sources (Fries, Muller and Srivastava 2003 Phys. Rev. Lett. 90 132301 (Preprint nucl-th/0208001); Zakharov 2004 JETP Lett. 80 617). Such predictions, as they currently exist, seem to be disfavoured by the PHENIX data; however, the idea is probably not ruled out. Finally, direct γ-jet correlations have been measured for the first time at RHIC and already show hints of medium modification

  19. Formation of η' mesons in photon-photon collisions

    International Nuclear Information System (INIS)

    Uitert, B.K. van.

    1986-01-01

    This thesis describes an experiment performed at the positron electron storage ring PEP at the Stanford Linear Accelerator Center on the formation of the η' resonance which is observed in its decay mode ρ 0 γ, where the ρ decays into a π + π - pair. Some general features of the relatively new subject of photon-photon physics are introduced. The η' and the coupling of photons to the η' are discussed in the context of the quark model. It is shown how the mixing angle in the nonet of pseudoscalar mesons can be derived from ratios of γγ widths. The kinematics of the two-photon exchange process, the formation of the η' resonance by the two virtual photons and its subsequent electromagnetic decay into ρ 0 γ are discussed. The selected sample of events is used to determine the γγ width of the η' under the conventional assignment J P = 0 - for the η' and J P = 1 - for the ρ. The result is combined with measurements by other experiments to a world average, which is used to determine the mixing angle for the pseudoscalar nonet under various assumptions. The decay angular and energy distributions are investigated in detail. (Auth.)

  20. The in-focus variable line spacing plane grating monochromator

    International Nuclear Information System (INIS)

    Reininger, R.

    2011-01-01

    The in-focus variable line spacing plane grating monochromator is based on only two plane optical elements, a variable line spacing plane grating and a plane pre-mirror that illuminates the grating at the angle of incidence that will focus the required photon energy. A high throughput beamline requires only a third optical element after the exit slit, an aberration corrected elliptical toroid. Since plane elements can be manufactured with the smallest figure errors, this monochromator design can achieve very high resolving power. Furthermore, this optical design can correct the deformations induced by the heat load on the optics along the dispersion plane. This should allow obtaining a resolution of 10 meV at 1 keV with currently achievable figure errors on plane optics. The position of the photon source when an insertion device center is not located at the center of the straight section, a common occurrence in new insertion device beamlines, is investigated.