WorldWideScience

Sample records for safety test observation

  1. Selenide isotope generator for the Galileo Mission: safety test plan

    International Nuclear Information System (INIS)

    1979-01-01

    The intent of this safety test plan is to outline particular kinds of safety tests designed to produce information which would be useful in the safety analysis process. The program deals primarily with the response of the RTG to accident environments; accordingly two criteria were established: (1) safety tests should be performed for environments which are the most critical in terms of risk contribution; and (2) tests should be formulated to determine failure conditions for critical heat source components rather than observe heat source response in reference accident environments. To satisfy criterion 1. results of a recent safety study were used to rank various accidents in terms of expected source terms. Six kinds of tests were then proposed which would provide information meeting the second criterion

  2. 9 CFR 113.39 - Cat safety tests.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Cat safety tests. 113.39 Section 113... Procedures § 113.39 Cat safety tests. The safety tests provided in this section shall be conducted when... recommended for use in cats. (a) The cat safety test provided in this paragraph shall be used when the Master...

  3. Safety of pulmonary function testing

    DEFF Research Database (Denmark)

    Roberts, Cara; Ward, Simon; Walsted, Emil

    2017-01-01

    BACKGROUND: Pulmonary function testing (PFT) is a key investigation in the evaluation of individuals with respiratory symptoms; however, the safety of routine and specialised PFT testing has not been reported in a large data set. Using patient safety incident (PSI) records, we aimed to assess risk...... was rated using the NHS National Patient Safety Agency and any hospital admission reported. RESULTS: There were 119 PSIs reported from 186 000 PFT; that is, 0.6 PSIs per 1000 tests. Cardiopulmonary PSIs were 3.3 times more likely to occur than non-cardiopulmonary (95% CI 2.17 to 5.12). Syncope was the most...

  4. FOOD SAFETY TESTING LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory develops screening assays, tests and modifies biosensor equipment, and optimizes food safety testing protocols for the military and civilian sector...

  5. Examination of cadmium safety rod thermal test specimens and failure mechanism evaluation

    International Nuclear Information System (INIS)

    Thomas, J.K.; Peacock, H.B.; Iyer, N.C.

    1992-01-01

    The reactor safety rods may be subjected to high temperatures due to gamma heating after the core coolant level has dropped during the ECS phase of a hypothetical LOCA event. Accordingly, an experimental cadmium safety rod testing subtask was established as part of a task to address the response of reactor core components to this accident. Companion reports describe the experiments and a structural evaluation (finite element analysis) of the safety rod. This report deals primarily with the examination of the test specimens, evaluation of possible failure mechanisms, and confirmatory separate effects experiments. It is concluded that the failures observed in the cadmium safety rod thermal tests which occurred at low temperature (T 800 degrees C) with fast thermal ramp rates are concluded to be mechanical in nature without significant environmental degradation. Based on these tests, tasks were initiated to design and manufacture B 4 C safety rods to replace the cadmium safety rods. The B 4 C safety rods have been manufactured at this time and it is currently planned to charge them to the reactor in the near future. 60 refs

  6. Tensile and burst tests in support of the cadmium safety rod failure evaluation

    International Nuclear Information System (INIS)

    Thomas, J.K.

    1992-02-01

    The reactor safety rods may be subjected to high temperatures due to gamma heating after the core coolant level has dropped during the ECS phase of hypothetical LOCA event. Accordingly, an experimental safety rod testing subtask was established as part of a task to address the response of reactor core components to this accident. This report discusses confirmatory separate effects tests conducted to support the evaluation of failures observed in the safety rod thermal tests. As part of the failure evaluation, the potential for liquid metal embrittlement (LME) of the safety rod cladding by cadmium (Cd) -- aluminum (Al) solutions was examined. Based on the test conditions, literature data, and U-Bend tests, its was concluded that the SS304 safety rod cladding would not be subject to LME by liquid Cd-Al solutions under conditions relevant to the safety rod thermal tests or gamma heating accident. To confirm this conclusion, tensile tests on SS304 specimens were performed in both air and liquid Cd-Al solutions with the range of strain rates, temperatures, and loading conditions spanning the range relevant to the safety rod thermal tests and gamma heating accident

  7. 9 CFR 113.40 - Dog safety tests.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Dog safety tests. 113.40 Section 113... Procedures § 113.40 Dog safety tests. The safety tests provided in this section shall be conducted when... recommended for use in dogs. Serials which are not found to be satisfactory when tested pursuant to the...

  8. 9 CFR 113.33 - Mouse safety tests.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Mouse safety tests. 113.33 Section 113.33 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE... Procedures § 113.33 Mouse safety tests. One of the mouse safety tests provided in this section shall be...

  9. Safety test facilities. Needs and concepts. A French evaluation

    International Nuclear Information System (INIS)

    Tretiakoff, O.; Bailly, J.

    1976-01-01

    The fuel behavior of LMFBRs in the event of an accident has been tested in-pile in the SCARABEE program. These tests will be carried on in the framework of an international cooperation on irradiated fuels: this is the purpose of the CABRI and SCARABEE N programs. All those studies should enable to assess safety margins between accident conditions and the technical specifications of the reactor. The purpose of this paper is to explain how a logical set of simple observations has led us to the present state of the Cadarache in-pile experimental safety program and how it may help us to find our way in a dense forest of both technical and psychological difficulties

  10. 46 CFR 61.40-6 - Periodic safety tests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Periodic safety tests. 61.40-6 Section 61.40-6 Shipping... INSPECTIONS Design Verification and Periodic Testing of Vital System Automation § 61.40-6 Periodic safety tests. (a) Periodic Safety tests must demonstrate the proper operation of the primary and alternate...

  11. Safety test facilities. Needs and concepts. A French evaluation

    International Nuclear Information System (INIS)

    Tretiakoff, O.; Bailly, J.

    1976-01-01

    The fuel behaviour of LMFBRs in the event of an accident has been tested in-pile in the SCARABEE program (local blockage, sudden flow reduction and pump coast-down at constant power). These tests will be carried on in the framework of an international cooperation on irradiated fuels: this is the purpose of the CABRI and SCARABEE N programs. All those studies should enable to assess safety margins between accident conditions and the technical specifications of the reactor. The paper explains how a logical set of simple observations has led to the present state of the Cadarache in-pile experimental safety program and how it may help to find the way in a dense forest of both technical and psychological difficulties

  12. Validation testing of safety-critical software

    International Nuclear Information System (INIS)

    Kim, Hang Bae; Han, Jae Bok

    1995-01-01

    A software engineering process has been developed for the design of safety critical software for Wolsung 2/3/4 project to satisfy the requirements of the regulatory body. Among the process, this paper described the detail process of validation testing performed to ensure that the software with its hardware, developed by the design group, satisfies the requirements of the functional specification prepared by the independent functional group. To perform the tests, test facility and test software were developed and actual safety system computer was connected. Three kinds of test cases, i.e., functional test, performance test and self-check test, were programmed and run to verify each functional specifications. Test failures were feedback to the design group to revise the software and test results were analyzed and documented in the report to submit to the regulatory body. The test methodology and procedure were very efficient and satisfactory to perform the systematic and automatic test. The test results were also acceptable and successful to verify the software acts as specified in the program functional specification. This methodology can be applied to the validation of other safety-critical software. 2 figs., 2 tabs., 14 refs. (Author)

  13. Safety Test Program Summary SNAP 19 Pioneer Heat Source Safety Program

    Energy Technology Data Exchange (ETDEWEB)

    None,

    1971-07-01

    Sixteen heat source assemblies have been tested in support of the SNAP 19 Pioneer Safety Test Program. Seven were subjected to simulated reentry heating in various plasma arc facilities followed by impact on earth or granite. Six assemblies were tested under abort accident conditions of overpressure, shrapnel impact, and solid and liquid propellant fires. Three capsules were hot impacted under Transit capsule impact conditions to verify comparability of test results between the two similar capsule designs, thus utilizing both Pioneer and Transit Safety Test results to support the Safety Analysis Report for Pioneer. The tests have shown the fuel is contained under all nominal accident environments with the exception of minor capsule cracks under severe impact and solid fire environments. No catastrophic capsule failures occurred in this test which would release large quantities of fuel. In no test was fuel visible to the eye following impact or fire. Breached capsules were defined as those which exhibit thoria contamination on its surface following a test, or one which exhibited visible cracks in the post test metallographic analyses.

  14. 9 CFR 113.38 - Guinea pig safety test.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Guinea pig safety test. 113.38 Section... Standard Procedures § 113.38 Guinea pig safety test. The guinea pig safety test provided in this section... be injected either intramuscularly or subcutaneously into each of two guinea pigs and the animals...

  15. Cadmium safety rod thermal tests

    International Nuclear Information System (INIS)

    Thomas, J.K.; Iyer, N.C.; Peacock, H.B.

    1992-01-01

    Thermal testing of cadmium safety rods was conducted as part of a program to define the response of Savannah River Site (SRS) production reactor core components to a hypothetical LOCA leading to a drained reactor tank. The safety rods are present in the reactor core only during shutdown and are not used as a control mechanism during operation; thus, their response to the conditions predicted for the LOCA is only of interest to the extent that it could impact the progression of the accident. This document provides a description of this testing

  16. Module Testing Techniques for Nuclear Safety Critical Software Using LDRA Testing Tool

    International Nuclear Information System (INIS)

    Moon, Kwon-Ki; Kim, Do-Yeon; Chang, Hoon-Seon; Chang, Young-Woo; Yun, Jae-Hee; Park, Jee-Duck; Kim, Jae-Hack

    2006-01-01

    The safety critical software in the I and C systems of nuclear power plants requires high functional integrity and reliability. To achieve those requirement goals, the safety critical software should be verified and tested according to related codes and standards through verification and validation (V and V) activities. The safety critical software testing is performed at various stages during the development of the software, and is generally classified as three major activities: module testing, system integration testing, and system validation testing. Module testing involves the evaluation of module level functions of hardware and software. System integration testing investigates the characteristics of a collection of modules and aims at establishing their correct interactions. System validation testing demonstrates that the complete system satisfies its functional requirements. In order to generate reliable software and reduce high maintenance cost, it is important that software testing is carried out at module level. Module testing for the nuclear safety critical software has rarely been performed by formal and proven testing tools because of its various constraints. LDRA testing tool is a widely used and proven tool set that provides powerful source code testing and analysis facilities for the V and V of general purpose software and safety critical software. Use of the tool set is indispensable where software is required to be reliable and as error-free as possible, and its use brings in substantial time and cost savings, and efficiency

  17. Test process for the safety-critical embedded software

    International Nuclear Information System (INIS)

    Sung, Ahyoung; Choi, Byoungju; Lee, Jangsoo

    2004-01-01

    Digitalization of nuclear Instrumentation and Control (I and C) system requires high reliability of not only hardware but also software. Verification and Validation (V and V) process is recommended for software reliability. But a more quantitative method is necessary such as software testing. Most of software in the nuclear I and C system is safety-critical embedded software. Safety-critical embedded software is specified, verified and developed according to V and V process. Hence two types of software testing techniques are necessary for the developed code. First, code-based software testing is required to examine the developed code. Second, after code-based software testing, software testing affected by hardware is required to reveal the interaction fault that may cause unexpected results. We call the testing of hardware's influence on software, an interaction testing. In case of safety-critical embedded software, it is also important to consider the interaction between hardware and software. Even if no faults are detected when testing either hardware or software alone, combining these components may lead to unexpected results due to the interaction. In this paper, we propose a software test process that embraces test levels, test techniques, required test tasks and documents for safety-critical embedded software. We apply the proposed test process to safety-critical embedded software as a case study, and show the effectiveness of it. (author)

  18. Performance Testing Methodology for Safety-Critical Programmable Logic Controller

    International Nuclear Information System (INIS)

    Kim, Chang Ho; Oh, Do Young; Kim, Ji Hyeon; Kim, Sung Ho; Sohn, Se Do

    2009-01-01

    The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC

  19. Utilizing the Fast Flux Test Facility for international passive safety testing

    International Nuclear Information System (INIS)

    Shen, P.K.; Padilla, A.; Lucoff, D.M.; Waltar, A.E.

    1991-01-01

    A two-phased approach has been undertaken in the Fast Flux Test Facility (FFTF) to conduct passive safety testing. Phase I (1986 to 1987) was structured to obtain an initial understanding of the reactivity feedback components. The planned Phase II (1992 to 1993) international program will extend the testing to include static and dynamic feedback measurements, transient and demonstration tests, and gas expansion module (GEM) reactivity tests. The primary objective is to meet the needs for safety analysis code validation, with particular emphasis on reducing the uncertainties associated with structure reactivity feedback. Program scope and predicted FFTF responses are discussed and illustrated. (author)

  20. 46 CFR 61.30-20 - Automatic control and safety tests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Automatic control and safety tests. 61.30-20 Section 61... TESTS AND INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-20 Automatic control and safety tests. Operational tests and checks of all safety and limit controls, combustion controls...

  1. Model-based testing for software safety

    NARCIS (Netherlands)

    Gurbuz, Havva Gulay; Tekinerdogan, Bedir

    2017-01-01

    Testing safety-critical systems is crucial since a failure or malfunction may result in death or serious injuries to people, equipment, or environment. An important challenge in testing is the derivation of test cases that can identify the potential faults. Model-based testing adopts models of a

  2. Review of design criteria and safety analysis of safety class electric building for fuel test loop

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. Y.

    1998-02-01

    Steady state fuel test loop will be equipped in HANARO to obtain the development and betterment of advanced fuel and materials through the irradiation tests. HANARO fuel test loop was designed for CANDU and PWR fuel testing. Safety related system of Fuel Test Loop such as emergency cooling water system, component cooling water system, safety ventilation system, high energy line break mitigation system and remote control room was required 1E class electric supply to meet the safety operation in accordance with related code. Therefore, FTL electric building was designed to construction and install the related equipment based on seismic category I. The objective of this study is to review the design criteria and analysis the safety function of safety class electric building for fuel test loop, and this results will become guidance for the irradiation testing in future. (author). 10 refs., 6 tabs., 30 figs.

  3. Stennis Space Center observes 2009 Safety and Health Day

    Science.gov (United States)

    2009-01-01

    Sue Smith, a medical clinic employee at NASA's John C. Stennis Space Center, takes the temperature of colleague Karen Badon during 2009 Safety and Health Day activities Oct. 22. Safety Day activities included speakers, informational sessions and a number of displays on safety and health issues. Astronaut Dominic Gorie also visited the south Mississippi rocket engine testing facility during the day to address employees and present several Silver Snoopy awards for outstanding contributions to flight safety and mission success. The activities were part of an ongoing safety and health emphasis at Stennis.

  4. Safety review on unit testing of safety system software of nuclear power plant

    International Nuclear Information System (INIS)

    Liu Le; Zhang Qi

    2013-01-01

    Software unit testing has an important place in the testing of safety system software of nuclear power plants, and in the wider scope of the verification and validation. It is a comprehensive, systematic process, and its documentation shall meet the related requirements. When reviewing software unit testing, attention should be paid to the coverage of software safety requirements, the coverage of software internal structure, and the independence of the work. (authors)

  5. Environmental assessment of general-purpose heat source safety verification testing

    International Nuclear Information System (INIS)

    1995-02-01

    This Environmental Assessment (EA) was prepared to identify and evaluate potential environmental, safety, and health impacts associated with the Proposed Action to test General-Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) assemblies at the Sandia National Laboratories (SNL) 10,000-Foot Sled Track Facility, Albuquerque, New Mexico. RTGs are used to provide a reliable source of electrical power on board some spacecraft when solar power is inadequate during long duration space missions. These units are designed to convert heat from the natural decay of radioisotope fuel into electrical power. Impact test data are required to support DOE's mission to provide radioisotope power systems to NASA and other user agencies. The proposed tests will expand the available safety database regarding RTG performance under postulated accident conditions. Direct observations and measurements of GPHS/RTG performance upon impact with hard, unyielding surfaces are required to verify model predictions and to ensure the continual evolution of the RTG designs that perform safely under varied accident environments. The Proposed Action is to conduct impact testing of RTG sections containing GPHS modules with simulated fuel. End-On and Side-On impact test series are planned

  6. [Use of complementary tests in emergencies and their relation with patient safety incidents].

    Science.gov (United States)

    Alcaraz-Martínez, J; Aranaz-Andrés, J M; Cantero-Sandoval, A; Piñera-Salmerón, P; Mas-Luzón, J; Serrano-Martínez, J A; González Garro, E

    2018-03-10

    To analyse the use of complementary tests and their relationship with safety incidents in hospital emergency departments. An analysis was performed on 935 patients seen in the 9 hospital emergency departments. The source of data used for the detection of incidents were: emergency department clinical record and reports, together with face-to-face observation in the department, plus a telephone survey of the patient or family member at one week after the care. Statistical tests used: The Student t test for quantitative variables, Chi squared test for qualitative variables, and the ANOVA test. A peripheral venous catheter was used in 397 patients (42.4% (95% CI; 39.3-45.5%)), with a variability with significant differences between hospitals (P<.01), with a range of use from 37% to 81.8%. It was also observed that in 23.4% (95% CI; 19.2-27.6%) of the cases, the catheter was not used after the first blood draw. Radiological tests were requested for 351 patients, 37.7% (95% CI; 34.6-40.8%), also with significant differences between hospitals (P<.01), ranging from 24.6 to 65, 1%. Incidents were detected in 95 (10.2%) patients (95% CI; 8.3-12.1%) in the all the study centres. A higher proportion of safety incidents have been observed in patients where peripheral venous catheter has been used (12.8%) than in those in whom they had not been used (8.5%) (P=.03), as well as in patients on whom an x-ray was requested (12.8%) compared to those who did not (8.64%) (P=.04). A longer stay was also observed in cases with an incident (mean 248.9minutes) than in those where there were none (mean 164.1minutes) (P<.001). No statistically significant differences were found in the other parameters studied. A relationship was observed between the use of a peripheral venous catheter (many of them without use) and radiological tests and the occurrence of safety incidents in the Emergency Departments. Copyright © 2018 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Preservation of FFTF Data Related to Passive Safety Testing

    International Nuclear Information System (INIS)

    Wootan, David W.; Butner, R. Scott; Omberg, Ronald P.; Makenas, Bruce J.; Nielsen, Deborah L.

    2010-01-01

    One of the goals of the Fuel Cycle Research and Development Program (FCRD) is to preserve the knowledge that has been gained in the United States on Liquid Metal Reactors (LMR). A key area deserving special attention for preservation is the data relating to passive safety testing that was conducted in FFTF and EBR-II during the 1980's. Accidents at Unit 4 of the Chernobyl Station and Unit 2 at Three Mile Island changed the safety paradigm of the nuclear power industry. New emphasis was placed on assured safety based on intrinsic plant characteristics that protect not only the public, but the significant investment in the plant as well. Plants designated to perform in this manner are considered to be passively safe since no active sensor/alarm system or human intervention is required to bring the reactor to a safe shutdown condition. The liquid metal reactor (LMR) has several key characteristics needed for a passively safe reactor: reactor coolant with superior heat transfer capability and very high boiling point, low (atmospheric) system pressures, and reliable negative reactivity feedback. The credibility of the design for a passively safe LMR rests on two issues: the validity of analytic methods used to predict passive safety performance and the availability of relevant test data to calibrate design tools. Safety analysis methods used to analyze LMRs under the old safety paradigm were focused on calculating the source term for the Core Disruptive Accident. Passive safety design requires refined analysis methods for transient events because treatment of the detailed reactivity feedbacks is important in predicting the response of the reactor. Similarly, analytic tools should be calibrated against actual test experience in existing LMR facilities. The principal objectives of the combined FFTF natural circulation and Passive Safety Testing program were: (1) to verify natural circulation as a reliable means to safely remove decay heat, (2) to extend passive safety

  8. Passive safety testing at the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Lucoff, D.M.

    1989-01-01

    During 1986, the Fast Flux Test Facility (FFTF) conducted several tests designed to improve the understanding of the passive safety characteristics of an oxide-fueled liquid-metal reactor (LMR). Static and dynamic tests were performed over a broad range of power, flow, and temperature conditions that extended beyond those for normal operation. Key results of these tests are presented. Stable operation at low power with natural circulation cooling was demonstrated. A passive safety enhancement feature, the gas expansion module (GEM) was developed specifically to offset the large amount of cooldown reactivity that needs to be controlled in an oxide-fueled LMR undergoing an unprotected loss-of-flow accident. Nine GEMs were built and successfully tested in FFTF. With the reactor at 50% power (200 MW (thermal)), the main coolant pumps were turned off and the normal control rod scram response was inhibited. The GEMs and inherent core reactivity feedback mechanisms took the core subcritical with a modest peak coolant temperature transient that reached 85 degrees C above the pretransient value and always maintained a >400 degrees C margin to the sodium boiling point (910 degrees C)

  9. Observational Pharmacoepidemiology in the Drug Safety and Effectiveness Evaluation

    Directory of Open Access Journals (Sweden)

    José Cabrita

    2017-04-01

    Full Text Available Observational epidemiological studies have been used in the medicines context for more than 40 years, contributing to characterize drug use patterns and safety, efficacy and effectiveness profiles. Its use has been increased in recognition of the clinical trials limitations to assess the therapeutic and iatrogenic potential of the medicines after its commercialization. The evolution of the regulatory framework for pharmacovigilance, requiring post-marketing studies, post-authorization safety studies (PASS and the post-authorization efficacy studies (PAES to approve certain drugs, reinforced the importance of observational pharmacoepidemiology for the characterization of the medicines safety and effectiveness profiles. Pharmacoepidemiological research can be carried out from field studies designed to obtain the necessary information or in databases with health records of population samples that already contain the information. This 2nd option is more efficient and more and more frequent. Although, observational research from field studies continues to have its space, the increasing availability of databases allowed a new development to observational pharmacoepidemiology. Indeed, access to automated records databases with up-to-date information on medical prescriptions and global health care to representative population samples with long follow-up periods is a valuable tool for the study of drug use patterns and therapeutic and iatrogenic potential in routine clinical practice. In this context, observational pharmacoepidemiology reinforces its role as a scientific area particularly suitable for evaluating the safety and the effectiveness of the medicines in the “real world”, making a relevant contribution to overcome the gap in translating the evidence from the clinical trials for clinical practice.

  10. Valve testing for UK PWR safety applications

    International Nuclear Information System (INIS)

    George, P.T.; Bryant, S.

    1989-01-01

    Extensive testing and development has been done by the Central Electricity Generating Board (CEGB) to support the design, construction and operation of Sizewell B, the UK's first PWR. A Blowdown Rig for the Assessment of Valve Operability - (BRAVO) has been constructed at the CEGB Marchwood Engineering Laboratory to reproduce PWR Pressurizer fluid conditions for the full scale testing of Pressurizer Relief System (PRS) valves. A full size tandem pair of Pilot Operated Safety Relief Valves (POSRVs) is being tested under the full range of pressurizer fluid conditions. Tests to date have produced important data on the performance of the valve in its Cold Overpressure protection mode of operation and on methods for the in-service testing of the valve. Also, a full size pressurizer safety valve has been tested under full PRS fluid conditions to develop a methodology for the pre-service testing of the Sizewell valves. Further work will be carried out to develop procedures for the in-service testing of the valve. In the Main Steam Safety Valve test program carried out at the Siemens-KWU Test Facilities, a single MSSV from three potential suppliers was tested under full secondary system conditions. The test results have been analyzed and are reflected in the CEGB's arrangements for the pre-service and in-service testing of the Sizewell MSSVs. Valves required to interrupt pipebreak flow must be qualified for this duty by testing or a combination of testing and analysis. To obtain guidance on the performance of such tests gate and globe valves have been subjected to simulated pipebreaks under PWR primary circuit conditions. In the light of problems encountered with gate valve closure under these conditions, further tests are currently being carried out on the BRAVO facility on a gate valve, in preparation for the full scale flow interruption qualification testing of the Sizewell main steam isolation valve

  11. Relevance of microbial finished product testing in food safety management

    DEFF Research Database (Denmark)

    Zwietering, Marcel H.; Jacxsens, Liesbeth; Membré, Jeanne Marie

    2016-01-01

    Management of microbiological food safety is largely based on good design of processes, products and procedures. Finished product testing may be considered as a control measure at the end of the production process. However, testing gives only very limited information on the safety status of a food......-active way by implementing an effective food safety management system. For verification activities in a food safety management system, finished product testing may however be useful. For three cases studies; canned food, chocolate and cooked ham, the relevance of testing both of finished products....... If a hazardous organism is found it means something, but absence in a limited number of samples is no guarantee of safety of a whole production batch. Finished product testing is often too little and too late. Therefore most attention should be focussed on management and control of the hazards in a more pro...

  12. Routine testing on protective and safety systems and components

    International Nuclear Information System (INIS)

    Rysy, W.

    1977-01-01

    1) In-process inspection, tests during commissioning. 2) Tests during reactor operation. 2.1) Reactor protection system, for example: continuous auto-testing by a dynamic system, check of the output signals; 2.2) safety features: selected examples: functional tests on the ECCS, trial operation of the emergency diesels. 3) Tests during refuelling phase. 3.1) Containment: Leakage rate tests, leak testing; 3.2) coolant system: selected examples: inservice inspections of the pressure vessel, eddy current testing of the steam generator, functional tests of safety valves. (orig./HP) [de

  13. Research on the improvement of nuclear safety -Thermal hydraulic tests for reactor safety system-

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Moon Kee; Park, Choon Kyung; Yang, Sun Kyoo; Chun, Se Yung; Song, Chul Hwa; Jun, Hyung Kil; Jung, Heung Joon; Won, Soon Yun; Cho, Yung Roh; Min, Kyung Hoh; Jung, Jang Hwan; Jang, Suk Kyoo; Kim, Bok Deuk; Kim, Wooi Kyung; Huh, Jin; Kim, Sook Kwan; Moon, Sang Kee; Lee, Sang Il [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-06-01

    The present research aims at the development of the thermal hydraulic verification test technology for the safety system of the conventional and advanced nuclear power plant and the development of the advanced thermal hydraulic measuring techniques. In this research, test facilities simulating the primary coolant system and safety system are being constructed for the design verification tests of the existing and advanced nuclear power plant. 97 figs, 14 tabs, 65 refs. (Author).

  14. Environmental tests of a digital safety channel: An investigation of stress-related vulnerabilities of computer-based safety system

    International Nuclear Information System (INIS)

    Korsah, K.; Wilson, T.L.; Wood, R.; Tanaka, T.

    1997-01-01

    This article presents the results of environmental stress tests performed on an experimental digital safety channel (EDSC) assembled at the Oak Ridge National Laboratory as part of the Qualification of Advanced Instrumentation and Controls Systems Research program, which was sponsored by the US Nuclear Regulatory Commission. The program is expected to provide recommendations for environmental qualification of digital safety systems. The purpose of the study was to investigate potential vulnerabilities of distributed computer systems used in safety applications when subjected to environmental stressors. The EDSC assembled for the tests employs technologies and digital subsystems representative of those proposed for use in advanced light-water reactors or as retrofits in existing plants. Subsystems include computers, electrical and optical serial communication links, fiber-optic network links, analog-to-digital and digital-to-analog converters, and multiplexers. The EDSC was subjected to selected stressors that are a potential risk to digital equipment in a mild environment. The selected stressors were electromagnetic and radiofrequency interferences (EMI-RFI), temperature, humidity, and smoke exposure. The stressors were applied at levels of intensity considerably higher than the safety channel is likely to experience in a normal nuclear power plant environment. Ranges of stress were selected at a sufficiently high level to induce errors so that failure modes that are characteristic of the technologies employed could be identified. On the basis of the incidence of functional errors observed during testing, EMI-RFI, smoke exposure, and high temperature coupled with high relative humidity, in that order, were found to have the greatest impact of the stressors investigated. The most prevalent stressor-induced upsets, as well as the most severe, were found to occur during the EMI-RFI tests

  15. 77 FR 2606 - Pipeline Safety: Random Drug Testing Rate

    Science.gov (United States)

    2012-01-18

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID PHMSA-2012-0004] Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials... pipelines and operators of liquefied natural gas facilities must select and test a percentage of covered...

  16. 75 FR 9018 - Pipeline Safety: Random Drug Testing Rate

    Science.gov (United States)

    2010-02-26

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket ID PHMSA-2010-0034] Pipeline Safety: Random Drug Testing Rate AGENCY: Pipeline and Hazardous Materials... pipelines and operators of liquefied natural gas facilities must select and test a percentage of covered...

  17. Directly observed road safety compliance by Motor Cycle Riders ...

    African Journals Online (AJOL)

    Objective: To assess the extent of compliance with road safety regulations by motorcycle riders following a five year road safety campaign in Naivasha town, Kenya. Design: A cross sectional study. Setting: Naivasha town, Nakuru county, Kenya. Results: A total of 9,280 MCs ferrying 13,733 people were observed. Less than ...

  18. Safety report content and development for test loop facility on MARIA reactor

    International Nuclear Information System (INIS)

    Konechko, A.; Shumskij, A.M.; Mikul'ahin, V.E.

    1982-01-01

    A 600 kW test loop facility for investigatin.o safety problems is realized on MARIA reactor in Poland together with USSR organizations. Safety reports have been developed in two steps at the designstage. The 1st report being essentially a preliminary safety analysis was developed within the scope of the feasibility study. At the engineering design stage the preliminary test loop facility safety report had been prepared considering measures excluding the possibility of the MARIA reactor damage. The test loop facility safety report is fulfilled for normal, transient and emergency operation regimes. Separate safety basing for each group of experiments will be prepared. The report presents the test loop facility safety criteria coordinated by the nuclear safety comission. They contains the preliminary reports on the test loop facility safety. At the final stage of construction and at thecommitioning stage the start-up safety report will be developed which after required correction and adding up the putting into operation data will turn into operation safety report [ru

  19. Quantification of Safety-Critical Software Test Uncertainty

    International Nuclear Information System (INIS)

    Khalaquzzaman, M.; Cho, Jaehyun; Lee, Seung Jun; Jung, Wondea

    2015-01-01

    The method, conservatively assumes that the failure probability of a software for the untested inputs is 1, and the failure probability turns in 0 for successful testing of all test cases. However, in reality the chance of failure exists due to the test uncertainty. Some studies have been carried out to identify the test attributes that affect the test quality. Cao discussed the testing effort, testing coverage, and testing environment. Management of the test uncertainties was discussed in. In this study, the test uncertainty has been considered to estimate the software failure probability because the software testing process is considered to be inherently uncertain. A reliability estimation of software is very important for a probabilistic safety analysis of a digital safety critical system of NPPs. This study focused on the estimation of the probability of a software failure that considers the uncertainty in software testing. In our study, BBN has been employed as an example model for software test uncertainty quantification. Although it can be argued that the direct expert elicitation of test uncertainty is much simpler than BBN estimation, however the BBN approach provides more insights and a basis for uncertainty estimation

  20. The effect of safety training involving non-destructive testing among students at specialized vocational high schools

    Energy Technology Data Exchange (ETDEWEB)

    Lim Young Khi [Dept. of Radiological Science, Gachon University, Inchon (Korea, Republic of); Han, Eun Ok; Choi, Yoon Seok [Dept. of Education amd Research, Korea Academy of Nuclear Safety, Seoul (Korea, Republic of)

    2017-06-15

    By examining the safety issues involved in on-site training sessions conducted at specialized vocational high schools, and by analyzing the effects of non-destructive testing (NDT) safety training, this study aims to contribute to ensuring the general safety of high school students. Students who expressed an interest in participation were surveyed regarding current NDT training practices, as well as NDT safety training. A total of 361 students from 4 schools participated in this study; 37.7% (136 students) were from the Seoul metropolitan area and 62.3% (225 students) were from other areas. Of the respondents, 2.2% (8 students) reported having engaged in NDT. As a result of safety training, statistically significant improvements were observed in most areas, except for individuals with previous NDT experience. The areas of improvement included safety awareness, acquisition of knowledge, subjective knowledge levels, objective knowledge levels, and adjustments to existing personal attitudes. Even at absolutely necessary observation-only training sessions, it is crucial that sufficient safety training and additional safety measures be adequately provided.

  1. The effect of safety training involving non-destructive testing among students at specialized vocational high schools

    International Nuclear Information System (INIS)

    Lim Young Khi; Han, Eun Ok; Choi, Yoon Seok

    2017-01-01

    By examining the safety issues involved in on-site training sessions conducted at specialized vocational high schools, and by analyzing the effects of non-destructive testing (NDT) safety training, this study aims to contribute to ensuring the general safety of high school students. Students who expressed an interest in participation were surveyed regarding current NDT training practices, as well as NDT safety training. A total of 361 students from 4 schools participated in this study; 37.7% (136 students) were from the Seoul metropolitan area and 62.3% (225 students) were from other areas. Of the respondents, 2.2% (8 students) reported having engaged in NDT. As a result of safety training, statistically significant improvements were observed in most areas, except for individuals with previous NDT experience. The areas of improvement included safety awareness, acquisition of knowledge, subjective knowledge levels, objective knowledge levels, and adjustments to existing personal attitudes. Even at absolutely necessary observation-only training sessions, it is crucial that sufficient safety training and additional safety measures be adequately provided

  2. Relocation work of temporary thermocouples for measuring the vessel cooling system in the safety demonstration test

    International Nuclear Information System (INIS)

    Shimazaki, Yosuke; Shinohara, Masanori; Ono, Masato; Yanagi, Shunki; Tochio, Daisuke; Iigaki, Kazuhiko

    2012-05-01

    It is necessary to confirm that the temperature of water cooling panel of the vessel cooling system (VCS) is controlled under the allowable working temperature during the safety demonstration test because the water cooling panel temperature rises due to stop of cooling water circulation pumps. Therefore, several temporary thermocouples are relocated to the water cooling panel near the stabilizers of RPV and the side cooling panel outlet ring header of VCS in order to observe the temperature change of VCS. The relocated thermocouples can measure the temperature change with starting of the cooling water circulation pumps of VCS. So it is confirmed that the relocated thermocouples can observe the VCS temperature change in the safety demonstration test. (author)

  3. Large-Scale Spacecraft Fire Safety Tests

    Science.gov (United States)

    Urban, David; Ruff, Gary A.; Ferkul, Paul V.; Olson, Sandra; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Cowlard, Adam J.; Rouvreau, Sebastien; Minster, Olivier; hide

    2014-01-01

    An international collaborative program is underway to address open issues in spacecraft fire safety. Because of limited access to long-term low-gravity conditions and the small volume generally allotted for these experiments, there have been relatively few experiments that directly study spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample sizes and environment conditions typical of those expected in a spacecraft fire. The major constraint has been the size of the sample, with prior experiments limited to samples of the order of 10 cm in length and width or smaller. This lack of experimental data forces spacecraft designers to base their designs and safety precautions on 1-g understanding of flame spread, fire detection, and suppression. However, low-gravity combustion research has demonstrated substantial differences in flame behavior in low-gravity. This, combined with the differences caused by the confined spacecraft environment, necessitates practical scale spacecraft fire safety research to mitigate risks for future space missions. To address this issue, a large-scale spacecraft fire experiment is under development by NASA and an international team of investigators. This poster presents the objectives, status, and concept of this collaborative international project (Saffire). The project plan is to conduct fire safety experiments on three sequential flights of an unmanned ISS re-supply spacecraft (the Orbital Cygnus vehicle) after they have completed their delivery of cargo to the ISS and have begun their return journeys to earth. On two flights (Saffire-1 and Saffire-3), the experiment will consist of a flame spread test involving a meter-scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. On one of the flights (Saffire-2), 9 smaller (5 x 30 cm) samples will be tested to evaluate NASAs material flammability screening tests

  4. Safety prediction for basic components of safety-critical software based on static testing

    International Nuclear Information System (INIS)

    Son, H.S.; Seong, P.H.

    2000-01-01

    The purpose of this work is to develop a safety prediction method, with which we can predict the risk of software components based on static testing results at the early development stage. The predictive model combines the major factor with the quality factor for the components, which are calculated based on the measures proposed in this work. The application to a safety-critical software system demonstrates the feasibility of the safety prediction method. (authors)

  5. Fast reactor safety testing in Transient Reactor Test (TREAT) in the 1980s

    International Nuclear Information System (INIS)

    Wright, A.E.; Dutt, D.S.; Harrison, L.J.

    1990-01-01

    Several series of fast reactor safety tests were performed in TREAT during the 1980s. These focused on the transient behavior of full-length oxide fuels (US reference, UK reference, and US advanced design) and on modern metallic fuels. Most of the tests addressed fuel behavior under transient overpower or loss-of-flow conditions. The test series were the PFR/TREAT tests; the RFT, TS, CDT, and RX series on oxide fuels; and the M series on metallic fuels. These are described in terms of their principal results and relevance to analyses and safety evaluation. 4 refs., 3 tabs

  6. Evaluation of safety test needs for the gas cooled breeder reactors

    International Nuclear Information System (INIS)

    Emon, D.E.; Buttemer, D.R.; Sevy, R.H.

    1976-01-01

    This paper deals with the process used in determining the safety test needs for the Gas Cooled Fast Breeder Reactor (GCFR), reports existing tentative conclusions, and indicates the direction that the process is taking at this time. The process is based upon two ideas: (1) that the safety information needs will be identified through risk analysis directly dependent on the various design features of the GCFR and (2) that the safety program will be determined by a safety review committee. The paper limits itself to presenting thoughts on the safety test needs directly associated with the GCFR core during severe beyond design basis accident situations involving the loss of coolable core geometry. Representative event sequence diagrams are reported for the three generic classes of accidents considered. The following categories of information are identified: safety information needs, safety tests required to fulfill these information needs, and the facilities required to perform the tests

  7. Safety demonstration test (SR-1/S1C-1) plan of HTTR (Contract research)

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Shigeaki; Sakaba, Nariaki; Takada, Eiji; Tachibana, Yukio; Saito, Kenji; Furusawa, Takayuki; Sawa, Kazuhiro [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    2003-03-01

    Safety demonstration tests in the HTTR (High Temperature Engineering Test Reactor) will be carried out in order to verify inherent safety features of the HTGR (High Temperature Gas-cooled Reactor). The first phase of the safety demonstration tests includes the reactivity insertion test by the control rod withdrawal and the coolant flow reduction test by the circulator trip. In the second phase, accident simulation tests will be conducted. By comparison of their experimental and analytical results, the prediction capability of the safety evaluation codes such as the core and the plant dynamics codes will be improved and verified, which will contribute to establish the safety design and the safety evaluation technologies of the HTGRs. The results obtained through its safety demonstration tests will be also utilised for the establishment of the safety design guideline, the safety evaluation guideline, etc. This paper describes the test program of the overall safety demonstration tests and the test method, the test conditions and the results of the pre-test analysis of the reactivity insertion test and the partial gas circulator trip test planned in March 2003. (author)

  8. Safety prediction for basic components of safety critical software based on static testing

    International Nuclear Information System (INIS)

    Son, H.S.; Seong, P.H.

    2001-01-01

    The purpose of this work is to develop a safety prediction method, with which we can predict the risk of software components based on static testing results at the early development stage. The predictive model combines the major factor with the quality factor for the components, both of which are calculated based on the measures proposed in this work. The application to a safety-critical software system demonstrates the feasibility of the safety prediction method. (authors)

  9. Observational Studies on Evaluating the Safety and Adverse Effects of Traditional Chinese Medicine

    Directory of Open Access Journals (Sweden)

    Jung-Nein Lai

    2013-01-01

    Full Text Available Background. This study aims to share our experiences when carrying out observational studies of traditional Chinese medicine (TCM. Methods. We have proactively monitored the safety profiles of Duhuo Jisheng Tang (DJT, Suan Zao Ren Tang (SZRT, and TMN-1. A list of adverse events (AEs, complete blood counts, and liver and kidney function tests were obtained from the participants during their scheduled hospital visits. Retrospective observational studies were conducted based on the reimbursement database of the National Health Insurance system, Taiwan, to explore the relationship between the use of TCM that have been adulterated by aristolochic acid and the risk from both nephrotoxins and carcinogens. Results. A total of 221, 287, and 203 AEs were detected after SZRT, DJT, and TMN-1 had been taken, respectively. Dizziness, headache, stomach ache, and diarrhea were judged to be probably related to SZRT treatment. Retrospective observational studies found an association between the consumption of aristolochic acid-containing Chinese formulae such as Mu Tong and an increased risk of CKD, ESRD, and urinary tract cancer. Conclusion. Prospective and retrospective observational studies seem to have specific advantages when investigating the safety and adverse effects of TCM therapies, as well as possibly other alternative/complementary therapies.

  10. Observational Studies on Evaluating the Safety and Adverse Effects of Traditional Chinese Medicine

    Science.gov (United States)

    Tang, Jin-Ling; Wang, Jung-Der

    2013-01-01

    Background. This study aims to share our experiences when carrying out observational studies of traditional Chinese medicine (TCM). Methods. We have proactively monitored the safety profiles of Duhuo Jisheng Tang (DJT), Suan Zao Ren Tang (SZRT), and TMN-1. A list of adverse events (AEs), complete blood counts, and liver and kidney function tests were obtained from the participants during their scheduled hospital visits. Retrospective observational studies were conducted based on the reimbursement database of the National Health Insurance system, Taiwan, to explore the relationship between the use of TCM that have been adulterated by aristolochic acid and the risk from both nephrotoxins and carcinogens. Results. A total of 221, 287, and 203 AEs were detected after SZRT, DJT, and TMN-1 had been taken, respectively. Dizziness, headache, stomach ache, and diarrhea were judged to be probably related to SZRT treatment. Retrospective observational studies found an association between the consumption of aristolochic acid-containing Chinese formulae such as Mu Tong and an increased risk of CKD, ESRD, and urinary tract cancer. Conclusion. Prospective and retrospective observational studies seem to have specific advantages when investigating the safety and adverse effects of TCM therapies, as well as possibly other alternative/complementary therapies. PMID:24159351

  11. Safety assessment of the SMART design during SBLOCA tests using the high pressure safety injection pump of the SMART-ITL facility

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hwang; Ryu, Sung Uk; Jeon, Byong-Guk; Yang, Jin-Hwa; Yoon, Eun-Koo; Shin, Yong-Cheol; Min, Kyoung-Ho; Park, Jong-Kuk; Choi, Nam-Hyun; Bang, Yun-Gon; Seo, Chan-Jong; Yi, Sung-Jae; Park, Hyun-Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    SMART is a small-sized integral pressurized light water reactor designed by the Korea Atomic Energy Research Institute (KAERI) from 1997 and received standard design approval (SDA) by the Korean regulatory body in July 2012. Single reactor pressure vessel contains all of the main components including a pressurizer (PZR), steam generators (SG) and reactor coolant pumps (RCP) without any large-size pipes. Several tests to verify a safety and performance of SMART design were carried out. This paper introduces a comparison with three SBLOCA tests. Overall thermal-hydraulic phenomena were observed and showed a traditional trend to decrease a system pressure and temperature. A collapsed water level of the hot side indicated that the safety injection system was successfully operated to recover the reactor coolant system (RCS) and protect the core uncover. An SBLOCA test simulating a guillotine break on the SIS, SCS, and PSV was performed. It was enough to keep a steady-state condition before the SBLOCA test begins. An actuation signal as the boundary condition was properly simulated during the transient test. The scenarios of the SBLOCA in the SMART design were reproduced well using the SMART-ITL facility. The safety injection is effective to protect the core uncover as well as to cool down the RCS. All of the measured parameters show reasonable behaviors.

  12. Safety assessment of the SMART design during SBLOCA tests using the high pressure safety injection pump of the SMART-ITL facility

    International Nuclear Information System (INIS)

    Bae, Hwang; Ryu, Sung Uk; Jeon, Byong-Guk; Yang, Jin-Hwa; Yoon, Eun-Koo; Shin, Yong-Cheol; Min, Kyoung-Ho; Park, Jong-Kuk; Choi, Nam-Hyun; Bang, Yun-Gon; Seo, Chan-Jong; Yi, Sung-Jae; Park, Hyun-Sik

    2016-01-01

    SMART is a small-sized integral pressurized light water reactor designed by the Korea Atomic Energy Research Institute (KAERI) from 1997 and received standard design approval (SDA) by the Korean regulatory body in July 2012. Single reactor pressure vessel contains all of the main components including a pressurizer (PZR), steam generators (SG) and reactor coolant pumps (RCP) without any large-size pipes. Several tests to verify a safety and performance of SMART design were carried out. This paper introduces a comparison with three SBLOCA tests. Overall thermal-hydraulic phenomena were observed and showed a traditional trend to decrease a system pressure and temperature. A collapsed water level of the hot side indicated that the safety injection system was successfully operated to recover the reactor coolant system (RCS) and protect the core uncover. An SBLOCA test simulating a guillotine break on the SIS, SCS, and PSV was performed. It was enough to keep a steady-state condition before the SBLOCA test begins. An actuation signal as the boundary condition was properly simulated during the transient test. The scenarios of the SBLOCA in the SMART design were reproduced well using the SMART-ITL facility. The safety injection is effective to protect the core uncover as well as to cool down the RCS. All of the measured parameters show reasonable behaviors

  13. Posttest analysis of the FFTF inherent safety tests

    International Nuclear Information System (INIS)

    Padilla, A. Jr.; Claybrook, S.W.

    1987-01-01

    Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis was not completed in time to perform pretest analyses. The purpose of this paper is to present the results of the posttest analysis of the 1986 FFTF inherent safety tests using the SASSYS code

  14. Safety significance of ATR [Advanced Test Reactor] passive safety response attributes

    International Nuclear Information System (INIS)

    Atkinson, S.A.

    1989-01-01

    The Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory was designed with some passive safety response attributes which contribute to the safety posture of the facility. The three passive safety attributes being evaluated in the paper are: (1) In-core and in-vessel natural convection cooling, (2) a passive heat sink capability of the ATR primary coolant system (PCS) for the transfer of decay power from the uninsulated piping to the confinement, and (3) gravity feed of emergency coolant makeup. The safety significance of the ATR passive safety response attributes is that the reactor can passively respond for most transients, given a reactor scram, to provide adequate decay power removal and a significant time for operator action should the normal active heat removal systems and their backup systems both fail. The ATR Interim Level 1 Probabilistic Risk Assessment (PRA) model ands results were used to evaluate the significance to ATR fuel damage frequency (or probability) of the above three passive response attributes. The results of the evaluation indicate that the first attribute is a major safety characteristic of the ATR. The second attribute has a noticeable but only minor safety significance. The third attribute has no significant influence on the ATR Level 1 PRA because of the diversity and redundancy of the ATR firewater injection system (emergency coolant system). 8 refs., 4 figs., 1 tab

  15. Formal testing and utilization of streaming media to improve flight crew safety knowledge.

    Science.gov (United States)

    Bellazzini, Marc A; Rankin, Peter M; Quisling, Jason; Gangnon, Ronald; Kohrs, Mike

    2008-01-01

    Increased concerns over the safety of air medical transport have prompted development of novel ways to increase safety. The objective of our study was to determine if an Internet streaming media safety video increased crew safety knowledge. 23 out of 40 crew members took an online safety pre-test, watched a safety video specific to our program and completed immediate and long-term post-testing 6 months later. Mean pre-test, post-test and 6 month follow up test scores were 84.9%, 92.3% and 88.4% respectively. There was a statistically significant difference in all scores (p Streaming media proved to be an accessible and effective supplement to safety training in our study.

  16. [Roadside observation on the use of safety belt in Guangzhou and Nanning cites of China].

    Science.gov (United States)

    Li, Li-ping; Stevenson, Mark; Ivers, Rebecca; Zhou, Ying

    2006-08-01

    To determine the rates of correct use of safety belt (CUSB) among drivers and front seat passengers in Guangzhou and Nanning through roadside observation and to provide scientific evidence for the development of intervention plan and to strengthen road safety law enforcement. Observational sites were randomly selected from three road types (Highway, Main Street and Subordinate Street). Targeted automobiles were observed at each site at four different times and uniformed checklists were used to record safety belt use during observations. Within each vehicle, belt use by drivers of different sex, road type, workday/weekend, day/night and seating position were calculated. Data was analyzed, using Chi-square tests to compare the statistic significance. (1)The rate of CUSB and non-use rate among drivers were higher in Nanning than in Guangzhou (P= 0.00) but the rate of incorrect use was on the contrarary. (2) The rate of CUSB by front seat passengers in Guangzhou was higher than that in Nanning (P = 0.04); as well as the rate of (P = 0.00) incorrect use while the non-use rate was on the contrarary. (3)In general, the rate of CUSB was higher on highways than on local streets (P = 0.00). (4) The CUSB rate of drivers and front seat passengers was higher at daytime than at night (P = 0.00), and the rate of incorrect use was higher at working days than weekends (P = 0.00). (5) The CUSB rate was higher for female drivers than for males in Guangzhou (P = 0.00), but there no statistical significance was found in Nanning (P = 0.21). Results suggested that intervention actions should be undertaken to raise the awareness of the importance of safety belt use. Effective public information and education programs, law enforcement and mandatory safety belt use, prioritizing programs on people neglegent to the importance are necessary to increase the safety belt use and to decrease the mortality and injuries caused by traffic accidents.

  17. Observed Food Safety Practices in the Summer Food Service Program

    Science.gov (United States)

    Patten, Emily Vaterlaus; Alcorn, Michelle; Watkins, Tracee; Cole, Kerri; Paez, Paola

    2017-01-01

    Purpose/Objectives: The purpose of this exploratory, observational study was three-fold: 1) Determine current food safety practices at Summer Food Service Program (SFSP) sites; 2) Identify types of food served at the sites and collect associated temperatures; and 3) Establish recommendations for food safety training in the SFSP.…

  18. Determination of the number of software tests using probabilistic safety assessment

    International Nuclear Information System (INIS)

    Kang, H. K.; Seong, T. Y.; Lee, K. Y.

    2000-01-01

    The broader usage of digital equipment in nuclear power plants gives rise to the safety problems of software. The field test should be performed before the software is used in critical applications because it is well known that software shows non-linear response when it is applied to different target systems in different environment. In the case of safety-critical applications, the result of tests contains usually zero failure case and the satisfiable number of tests is hard to be determined. In this paper, we suggests the method to determine the number of software tests without failure using the probabilistic safety assessment. From the result of the probabilistic safety assessment on total system, the desirable unavailability of software is calculated and the number of tests is determined

  19. Technique for unit testing of safety software verification and validation

    International Nuclear Information System (INIS)

    Li Duo; Zhang Liangju; Feng Junting

    2008-01-01

    The key issue arising from digitalization of the reactor protection system for nuclear power plant is how to carry out verification and validation (V and V), to demonstrate and confirm the software that performs reactor safety functions is safe and reliable. One of the most important processes for software V and V is unit testing, which verifies and validates the software coding based on concept design for consistency, correctness and completeness during software development. The paper shows a preliminary study on the technique for unit testing of safety software V and V, focusing on such aspects as how to confirm test completeness, how to establish test platform, how to develop test cases and how to carry out unit testing. The technique discussed here was successfully used in the work of unit testing on safety software of a digital reactor protection system. (authors)

  20. Safety Assurance for Irradiating Experiments in the Advanced Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    T. A. Tomberlin; S. B. Grover

    2004-11-01

    The Advanced Test Reactor (ATR), located at the Idaho National Engineering and Environmental Laboratory (INEEL), was specifically designed to provide a high neutron flux test environment for conducting a variety of experiments. This paper addresses the safety assurance process for two general types of experiments conducted in the ATR facility and how the safety analyses for experiments are related to the ATR safety basis. One type of experiment is more routine and generally represents greater risks; therefore, this type of experiment is addressed in more detail in the ATR safety basis. This allows the individual safety analysis for this type of experiment to be more standardized. The second type of experiment is defined in more general terms in the ATR safety basis and is permitted under more general controls. Therefore, the individual safety analysis for the second type of experiment tends to be more unique and is tailored to each experiment.

  1. Safety Assurance for Irradiating Experiments in the Advanced Test Reactor

    International Nuclear Information System (INIS)

    T. A. Tomberlin; S. B. Grover

    2004-01-01

    The Advanced Test Reactor (ATR), located at the Idaho National Engineering and Environmental Laboratory (INEEL), was specifically designed to provide a high neutron flux test environment for conducting a variety of experiments. This paper addresses the safety assurance process for two general types of experiments conducted in the ATR facility and how the safety analyses for experiments are related to the ATR safety basis. One type of experiment is more routine and generally represents greater risks; therefore, this type of experiment is addressed in more detail in the ATR safety basis. This allows the individual safety analysis for this type of experiment to be more standardized. The second type of experiment is defined in more general terms in the ATR safety basis and is permitted under more general controls. Therefore, the individual safety analysis for the second type of experiment tends to be more unique and is tailored to each experiment

  2. Guide On Safety Tests

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1987-05-15

    This book tells US important things to do safety tests, which includes basic caution for experiment treatment of used materials such as ignition substance inflammables, explosive substance and toxic substance, handling of used equipment like inflammable device, machine, high pressure device, high pressure gas, and high energy device, first aid such as addiction by drug, flame, radiation exposure, and heart massage treatment of waste in laboratory like cautions on general treatment, handling of inorganic waste, organic waste and waste treatment with disposal facilities.

  3. Guide On Safety Tests

    International Nuclear Information System (INIS)

    1987-05-01

    This book tells US important things to do safety tests, which includes basic caution for experiment treatment of used materials such as ignition substance inflammables, explosive substance and toxic substance, handling of used equipment like inflammable device, machine, high pressure device, high pressure gas, and high energy device, first aid such as addiction by drug, flame, radiation exposure, and heart massage treatment of waste in laboratory like cautions on general treatment, handling of inorganic waste, organic waste and waste treatment with disposal facilities.

  4. Safety Testing of Ammonium Nitrate Based Mixtures

    Science.gov (United States)

    Phillips, Jason; Lappo, Karmen; Phelan, James; Peterson, Nathan; Gilbert, Don

    2013-06-01

    Ammonium nitrate (AN)/ammonium nitrate based explosives have a lengthy documented history of use by adversaries in acts of terror. While historical research has been conducted on AN-based explosive mixtures, it has primarily focused on detonation performance while varying the oxygen balance between the oxidizer and fuel components. Similarly, historical safety data on these materials is often lacking in pertinent details such as specific fuel type, particle size parameters, oxidizer form, etc. A variety of AN-based fuel-oxidizer mixtures were tested for small-scale sensitivity in preparation for large-scale testing. Current efforts focus on maintaining a zero oxygen-balance (a stoichiometric ratio for active chemical participants) while varying factors such as charge geometry, oxidizer form, particle size, and inert diluent ratios. Small-scale safety testing was conducted on various mixtures and fuels. It was found that ESD sensitivity is significantly affected by particle size, while this is less so for impact and friction. Thermal testing is in progress to evaluate hazards that may be experienced during large-scale testing.

  5. Relevance of microbial finished product testing in food safety management

    NARCIS (Netherlands)

    Zwietering, M.H.; Jacxsens, L.; Membre, J.M.; Nauta, M.; Peterz, M.

    2016-01-01

    Management of microbiological food safety is largely based on good design of processes, products and procedures. Finished product testing may be considered as a control measure at the end of the production process. However, testing gives only very limited information on the safety status of a food.

  6. The Safety Feature Test of QNX RTOS

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jang Yeol; Lee, Young Jun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-05-15

    Benchmarking is a point of reference by which something can be measured. The QNX is a kind of Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available PC to be applied such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS-AC). The ELMSYS PC Hardware will be qualified by KTL(Korea Testing Lab.) in order to use as a Cabinet Operator Module(COM). QNX RTOS is dedicating by KAERI now. This paper describes the outline and some safety features among benchmarking test for QNX RTOS under the ELMSYS PC platform

  7. The Safety Feature Test of QNX RTOS

    International Nuclear Information System (INIS)

    Kim, Jang Yeol; Lee, Young Jun

    2010-01-01

    Benchmarking is a point of reference by which something can be measured. The QNX is a kind of Real Time Operating System(RTOS) developed by QSSL(QNX Software Systems Ltd.) in Canada. The ELMSYS is the brand name of commercially available PC to be applied such as Cabinet Operator Module(COM) of Digital Plant Protection System(DPPS) and COM of Digital Engineered Safety Features Actuation System(DESFAS-AC). The ELMSYS PC Hardware will be qualified by KTL(Korea Testing Lab.) in order to use as a Cabinet Operator Module(COM). QNX RTOS is dedicating by KAERI now. This paper describes the outline and some safety features among benchmarking test for QNX RTOS under the ELMSYS PC platform

  8. Neurovirulence safety testing of mumps vaccines--historical perspective and current status.

    Science.gov (United States)

    Rubin, S A; Afzal, M A

    2011-04-05

    Many live, attenuated viral vaccines are derived from wild type viruses with known neurovirulent properties. To assure the absence of residual neurotoxicity, pre-clinical neurovirulence safety testing of candidate vaccines is performed. For mumps virus, a highly neurotropic virus, neurovirulence safety testing is performed in monkeys. However, laboratory studies suggest an inability of this test to correctly discern among virus strains of varying neurovirulence potential in man, and, further, some vaccines found to be neuroattenuated in monkeys were later found to be neurovirulent in humans when administered in large numbers. Over the past decade, concerted efforts have been made to replace monkey-based neurovirulence safety testing with more informative, alternative methods. This review summarizes the current status of mumps vaccine neurovirulence safety testing and insights into models currently approved and those under development. Published by Elsevier Ltd.

  9. Role of field testing and shaking table test on full scale structure for NPP seismic-safety, and its relation to computational mechanics

    International Nuclear Information System (INIS)

    Shibata, Heki

    1988-01-01

    Field testing on the dynamic behavior of actual structures is significant for the seismic safety of nuclear power plants. For their mechanical components and piping systems, the full scale testings are also important as well as the in-situ test of buildings. In general, it is often observed that they don't behave as that of analytical model for the design. This article tries to discuss how such discrepancy is occurring, and how to overcome it. (author)

  10. Role of field testing and shaking table test on full scale structure for NPP seismic-safety, and its relation to computational mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Heki [Institute of Industrial Science, University of Tokyo (Japan)

    1988-07-01

    Field testing on the dynamic behavior of actual structures is significant for the seismic safety of nuclear power plants. For their mechanical components and piping systems, the full scale testings are also important as well as the in-situ test of buildings. In general, it is often observed that they don't behave as that of analytical model for the design. This article tries to discuss how such discrepancy is occurring, and how to overcome it. (author)

  11. Stress Tests Worldwide - IAEA Nuclear Safety Action Plan

    International Nuclear Information System (INIS)

    Lyons, J.E.

    2012-01-01

    The IAEA nuclear safety action plan relies on 11 important issues. 1) Safety assessments in light of the Fukushima accident: the IAEA secretariat will develop a methodology for stress tests against specific extreme natural hazards and will provide assistance for their implementation; 2) Strengthen existing IAEA peer reviews; 3) Emergency preparedness and response; 4) National Regulatory bodies in terms of independence and adequacy of human and financial resources; 5) The development of safety culture and scientific and technical capacity in Operating Organizations; 6) The upgrading of IAEA safety standards in a more efficient way; 7) A better implementation of relevant conventions concerning nuclear safety and nuclear accidents; 8) To provide a broad assistance on safety standard for countries embarking on a nuclear power program; 9) To facilitate the use of available information, expertise and techniques concerning radiation protection; 10) To enhance the transparency of nuclear industry; and 11) To promote the cooperation between member states in nuclear safety. (A.C.)

  12. Safety testing of GM-rice expressing PHA-E lectin using a new animal test design

    DEFF Research Database (Denmark)

    Poulsen, Morten; Schrøder, Malene; Wilcks, Andrea

    2007-01-01

    The 90-day animal study is the core study for the safety assessment of genetically modified foods in the SAFOTEST project. The model compound tested in the 90-day study was a rice variety expressing the kidney bean Phaseolus vulgaris lectin agglutinin E-form (PHA-E lectin). Female Wistar rats were...... safety testing of genetically modified foods....

  13. Safety tests carried out at Cadarache. Sodium fires

    International Nuclear Information System (INIS)

    Fruchard, M.

    1976-01-01

    Safety test on sodium fires developed at the Cadarache Nuclear Centre by the Department of Nuclear Safety, section of safety experiments on radioactivity transfer are conducted in two main directions: analysis of the behavior and thermodynamic consequences of accidental fires, working on the basis of typical experimental results; research and development of methods and equipment to control and if possible extinguish these fires. The most important part of this programme is concerned with the sodium pool fires which would result from the failure of a secondary coolant circuit pipe [fr

  14. Gas reactor in-pile safety test project (GRIST-2)

    International Nuclear Information System (INIS)

    Kelley, A.P. Jr.; Arbtin, E.; St Pierre, R.

    1979-01-01

    Although out-of-pile tests may be expected to confirm individual phenomena models in core disruptive accident analysis codes, only in-pile tests are capable of verifying the extremely complex integrated model effects within the appropriate time phase for these accidents. For this reason, the GRIST-2 project, the purpose of which is to design and construct an in-pile helium loop capable of transient safety testing in the TREAT facility in Idaho, forms a cornerstone of the US GCFR safety program. The project organization, experiment program, facility, helium system design, and schedule which have been selected to meet the objectives are described

  15. Business of Nuclear Safety Analysis Office, Nuclear Technology Test Center

    International Nuclear Information System (INIS)

    Hayakawa, Masahiko

    1981-01-01

    The Nuclear Technology Test Center established the Nuclear Safety Analysis Office to execute newly the works concerning nuclear safety analysis in addition to the works related to the proving tests of nuclear machinery and equipments. The regulations for the Nuclear Safety Analysis Office concerning its organization, business and others were specially decided, and it started the business formally in August, 1980. It is a most important subject to secure the safety of nuclear facilities in nuclear fuel cycle as the premise of developing atomic energy. In Japan, the strict regulation of safety is executed by the government at each stage of the installation, construction, operation and maintenance of nuclear facilities, based on the responsibility for the security of installers themselves. The Nuclear Safety Analysis Office was established as the special organ to help the safety examination related to the installation of nuclear power stations and others by the government. It improves and puts in order the safety analysis codes required for the cross checking in the safety examination, and carries out safety analysis calculation. It is operated by the cooperation of the Science and Technology Agency and the Agency of Natural Resources and Energy. The purpose of establishment, the operation and the business of the Nuclear Safety Analysis Office, the plan of improving and putting in order of analysis codes, and the state of the similar organs in foreign countries are described. (Kako, I.)

  16. Allowed outage time for test and maintenance - Optimization of safety

    International Nuclear Information System (INIS)

    Cepin, M.; Mavko, B.

    1997-01-01

    The main objective of the project is the development and application of methodologies for improvement and optimization of test and maintenance activities for safety related equipment in NPPs on basis of their enhanced safety. The probabilistic safety assessment serves as a base, which does not mean the replacement of the deterministic analyses but the consideration of probabilistic safety assessment results as complement to deterministic results. 15 refs, 2 figs

  17. Testing existing software for safety-related applications. Revision 7.1

    International Nuclear Information System (INIS)

    Scott, J.A.; Lawrence, J.D.

    1995-12-01

    The increasing use of commercial off-the-shelf (COTS) software products in digital safety-critical applications is raising concerns about the safety, reliability, and quality of these products. One of the factors involved in addressing these concerns is product testing. A tester's knowledge of the software product will vary, depending on the information available from the product vendor. In some cases, complete source listings, program structures, and other information from the software development may be available. In other cases, only the complete hardware/software package may exist, with the tester having no knowledge of the internal structure of the software. The type of testing that can be used will depend on the information available to the tester. This report describes six different types of testing, which differ in the information used to create the tests, the results that may be obtained, and the limitations of the test types. An Annex contains background information on types of faults encountered in testing, and a Glossary of pertinent terms is also included. This study is pertinent for safety-related software at reactors

  18. Development of Safety Grade PLC (POSAFE-Q) and Performance Test Results

    International Nuclear Information System (INIS)

    Kim, Chang Hwoi; Park, Won Man; Choi, Jong Gyun; Lee, Dong Young; No, Young Hun; Song, Seung Hwan

    2006-01-01

    The safety grade PLC (POSAFE-Q) is being developed in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as the RTOS and firmware are being developed according to the safety critical software life cycle. Especially, the formal method is applied to design the SRS (Software Requirement Spec.) and the SDS (Software Design Specification.) to be error-free. The POSAFE-Q has several modules such as processor module, input and output modules, communication modules, redundant processor module, redundant power modules, etc,. To verify the function and performance, several tests such as CT, IT and ST were performed. And also, the equipment qualification test for environment, EMI and EMC, and seismic ware performed. All tests are satisfied with the requirements and specification for safety grade PLC, and the criteria for safety system in nuclear power plants

  19. Development of Safety Grade PLC (POSAFE-Q) and Performance Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hwoi; Park, Won Man; Choi, Jong Gyun; Lee, Dong Young [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); No, Young Hun; Song, Seung Hwan [POSCON, Seoul (Korea, Republic of)

    2006-07-01

    The safety grade PLC (POSAFE-Q) is being developed in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as the RTOS and firmware are being developed according to the safety critical software life cycle. Especially, the formal method is applied to design the SRS (Software Requirement Spec.) and the SDS (Software Design Specification.) to be error-free. The POSAFE-Q has several modules such as processor module, input and output modules, communication modules, redundant processor module, redundant power modules, etc,. To verify the function and performance, several tests such as CT, IT and ST were performed. And also, the equipment qualification test for environment, EMI and EMC, and seismic ware performed. All tests are satisfied with the requirements and specification for safety grade PLC, and the criteria for safety system in nuclear power plants.

  20. Timed Testing under Partial Observability

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Li, Shuhao

    2009-01-01

    observability of SUT using a set of predicates over the TGA state space, and specify the test purposes in Computation Tree Logic (CTL) formulas. A recently developed partially observable timed game solver is used to generate winning strategies, which are used as test cases. We propose a conformance testing...

  1. The role of natural circulation in the FFTF [Fast Flux Test Facility] passive safety tests

    International Nuclear Information System (INIS)

    Stover, R.L.; Padilla, A.; Burke, T.M.; Knecht, W.L.

    1987-03-01

    A series of tests were completed at the Fast Flux Test Facility to demonstrate the passive safety characteristics of liquid metal reactors with natural circulation flow. The first test consisted of transition from forced to natural circulation flow at an initial decay power of 0.3%. The second test represented an unprotected loss-of-flow transient to natural circulation from 50% power with the control rods prevented from scramming into the core. The third test was a steady-state, natural circulation condition with core fission powers up ato about 2.3%. Core sodium data and results of single and multi-channel computer models confirmed the reliability and effectiveness of natural circulation flow for liquid metal reactor safety

  2. Using Total Lightning Observations to Enhance Lightning Safety

    Science.gov (United States)

    Stano, Geoffrey T.

    2012-01-01

    Lightning is often the underrated threat faced by the public when it comes to dangerous weather phenomena. Typically, larger scale events such as floods, hurricanes, and tornadoes receive the vast majority of attention by both the general population and the media. This comes from the fact that these phenomena are large, longer lasting, can impact a large swath of society at one time, and are dangerous events. The threat of lightning is far more isolated on a case by case basis, although millions of cloud-to-ground lightning strikes hit this United States each year. While attention is given to larger meteorological events, lightning is the second leading cause of weather related deaths in the United States. This information raises the question of what steps can be taken to improve lightning safety. Already, the meteorological community s understanding of lightning has increased over the last 20 years. Lightning safety is now better addressed with the National Weather Service s access to the National Lightning Detection Network data and enhanced wording in their severe weather warnings. Also, local groups and organizations are working to improve public awareness of lightning safety with easy phrases to remember, such as "When Thunder Roars, Go Indoors." The impacts can be seen in the greater array of contingency plans, from airports to sports stadiums, addressing the threat of lightning. Improvements can still be made and newer technologies may offer new tools as we look towards the future. One of these tools is a network of sensors called a lightning mapping array (LMA). Several of these networks exist across the United States. NASA s Short-term Prediction Research and Transition Center (SPoRT), part of the Marshall Spaceflight Center, has access to three of these networks from Huntsville, Alabama, the Kennedy Space Center, and Washington D.C. The SPoRT program s mission is to help transition unique products and observations into the operational forecast environment

  3. General-Purpose Heat Source development: Safety Verification Test Program. Bullet/fragment test series

    Energy Technology Data Exchange (ETDEWEB)

    George, T.G.; Tate, R.E.; Axler, K.M.

    1985-05-01

    The radioisotope thermoelectric generator (RTG) that will provide power for space missions contains 18 General-Purpose Heat Source (GPHS) modules. Each module contains four /sup 238/PuO/sub 2/-fueled clads and generates 250 W/sub (t)/. Because a launch-pad or post-launch explosion is always possible, we need to determine the ability of GPHS fueled clads within a module to survive fragment impact. The bullet/fragment test series, part of the Safety Verification Test Plan, was designed to provide information on clad response to impact by a compact, high-energy, aluminum-alloy fragment and to establish a threshold value of fragment energy required to breach the iridium cladding. Test results show that a velocity of 555 m/s (1820 ft/s) with an 18-g bullet is at or near the threshold value of fragment velocity that will cause a clad breach. Results also show that an exothermic Ir/Al reaction occurs if aluminum and hot iridium are in contact, a contact that is possible and most damaging to the clad within a narrow velocity range. The observed reactions between the iridium and the aluminum were studied in the laboratory and are reported in the Appendix.

  4. Finite test sets development method for test execution of safety critical software

    International Nuclear Information System (INIS)

    Shin, Sung Min; Kim, Hee Eun; Kang, Hyun Gook; Lee, Sung Jiun

    2014-01-01

    The V and V method has been utilized for this safety critical software, while SRGM has difficulties because of lack of failure occurrence data on developing phase. For the safety critical software, however, failure data cannot be gathered after installation in real plant when we consider the severe consequence. Therefore, to complement the V and V method, the test-based method need to be developed. Some studies on test-based reliability quantification method for safety critical software have been conducted in nuclear field. These studies provide useful guidance on generating test sets. An important concept of the guidance is that the test sets represent 'trajectories' (a series of successive values for the input variables of a program that occur during the operation of the software over time) in the space of inputs to the software.. Actually, the inputs to the software depends on the state of plant at that time, and these inputs form a new internal state of the software by changing values of some variables. In other words, internal state of the software at specific timing depends on the history of past inputs. Here the internal state of the software which can be changed by past inputs is named as Context of Software (CoS). In a certain CoS, a software failure occurs when a fault is triggered by some inputs. To cover the failure occurrence mechanism of a software, preceding researches insist that the inputs should be a trajectory form. However, in this approach, there are two critical problems. One is the length of the trajectory input. Input trajectory should long enough to cover failure mechanism, but the enough length is not clear. What is worse, to cover some accident scenario, one set of input should represent dozen hours of successive values. The other problem is number of tests needed. To satisfy a target reliability with reasonable confidence level, very large number of test sets are required. Development of this number of test sets is a herculean

  5. Safety analysis report of the irradiation test of Type-B bundle

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choong Sung; Lim, I. C.; Lee, B. C.; Ryu, J. S.; Kim, H. R

    2000-06-01

    The HANARO fuel, U{sub 3}Si-A1, has been developed by AECL and tested in NRU reactor. In the course of the fuel qualification tests, only one case was performed under the higher power condition than maximum linear power which was expected in the design stage. The Korea regulatory body, KINS imposed that HANARO shall be operated at the power level less than 24MW which is 80% of the design full power until HANARO shows the repetitive performance of the fuel at the power condition abov e 112.8KW/m. To resolve this imposition, KAERI designed two types of special test bundles: two non-instrumented(Type-A) and one instrumented(Type-B) test bundles. Two Type-A bundles were irradiated in HANARO: one of them has finished PIE and the other is under PIE. Type-B bundle was loaded in the core during 1.32 day at 1996, but outstanding FIV(flow induced vibration) was observed at the pool top because of long guide tube attached to the top of the bundle. The successful installation of the chimney fastener to fix the guide tube resulted in conducting the irradiation test of Type-B bundle again. The test will start at mid- July, 2000. In order to safely do the Type-B irradiation test, the safety analysis for the nuclear, mechanical and thermal-hydraulic aspects was performed. The reactivity worth and the maximum 1 near power predicted by VENTURE are 6.3mk/k and 121.6kW/m, respectively. Thermal margins for normal and transient conditions using MATRA-h, are assessed to satisfy the safety criteria.

  6. Combustion Safety Simplified Test Protocol Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L. [Gas Technology Inst., Des Plaines, IL (United States); Cautley, D. [Gas Technology Inst., Des Plaines, IL (United States); Bohac, D. [Gas Technology Inst., Des Plaines, IL (United States); Francisco, P. [Gas Technology Inst., Des Plaines, IL (United States); Shen, L. [Gas Technology Inst., Des Plaines, IL (United States); Gloss, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-11-01

    Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project team collected field data on 11 houses in 2015.

  7. Some Findings from Thermal-Hydraulic Validation Tests for SMART Passive Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun Sik; Bae, Hwang; Ryu, Sung-Uk; Ryu, Hyobong; Shin, Yong-Cheol; Min, Kyoung-Ho; Yi, Sung-Jae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    To satisfy the domestic and international needs for nuclear safety improvement after the Fukushima accident, an effort to improve its safety has been studied, and a Passive Safety System (PSS) for SMART has been designed. In addition, an Integral Test Loop for the SMART design (SMART-ITL, or FESTA) has been constructed and it finished its commissioning tests in 2012. Consequently, a set of Design Base Accident (DBA) scenarios have been simulated using SMARTITL. Recently, a test program to validate the performance of the SMART PSS was launched and its scaled-down test facility was additionally installed at the existing SMART-ITL facility. In this paper, some findings from the validation tests for the SMART PSS will be summarized. The acquired data will be used to validate the safety analysis code and its related models, to evaluate the performance of SMART PSS, and to provide base data during the application phase of SDA revision and construction licensing. A test program to validate the performance of SMARS PSS was launched with an additional scaleddown test facility of SMART PSS, which will be installed at the existing SMART-ITL facility. In this paper, some findings from the validation tests of the SMART passive safety system during 2013-2014 were summarized. They include a couple of SMART PSS tests using active pumps and several 1-train SMART PSS tests. From the test results it was estimated that the SMART PSS has sufficient cooling capability to deal with the SBLOCA scenario of SMART. During the SBLOCA scenario, in the CMT the water layer inventory was well stratified thermally and the safety injection water was injected efficiently into the RPV from the initial period and cools down the RCS properly.

  8. Validation test case generation based on safety analysis ontology

    International Nuclear Information System (INIS)

    Fan, Chin-Feng; Wang, Wen-Shing

    2012-01-01

    Highlights: ► Current practice in validation test case generation for nuclear system is mainly ad hoc. ► This study designs a systematic approach to generate validation test cases from a Safety Analysis Report. ► It is based on a domain-specific ontology. ► Test coverage criteria have been defined and satisfied. ► A computerized toolset has been implemented to assist the proposed approach. - Abstract: Validation tests in the current nuclear industry practice are typically performed in an ad hoc fashion. This study presents a systematic and objective method of generating validation test cases from a Safety Analysis Report (SAR). A domain-specific ontology was designed and used to mark up a SAR; relevant information was then extracted from the marked-up document for use in automatically generating validation test cases that satisfy the proposed test coverage criteria; namely, single parameter coverage, use case coverage, abnormal condition coverage, and scenario coverage. The novelty of this technique is its systematic rather than ad hoc test case generation from a SAR to achieve high test coverage.

  9. Physics design of fast reactor safety test facilities for in-pile experiments

    International Nuclear Information System (INIS)

    Travelli, A.; Matos, J.E.; Snelgrove, J.L.; Shaftman, D.H.; Tzanos, C.P.; Lam, S.K.; Pennington, E.M.; Woodruff, W.L.

    1976-01-01

    A determined effort to identify and resolve current Fast Breeder Reactor safety testing needs has recently resulted in a number of conceptual designs for FBR safety test facilities which are very complex and diverse both in their features and in their purpose. The paper discusses the physics foundations common to most fast reactor safety test facilities and the constraints which they impose on the design. The logical evolution, features, and capabilities of several major conceptual designs are discussed on the basis of this common background

  10. Combustion Safety Simplified Test Protocol Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Brand, L [Gas Technology Inst., Des Plaines, IL (United States); Cautley, D. [Gas Technology Inst., Des Plaines, IL (United States); Bohac, D. [Gas Technology Inst., Des Plaines, IL (United States); Francisco, P. [Gas Technology Inst., Des Plaines, IL (United States); Shen, L. [Gas Technology Inst., Des Plaines, IL (United States); Gloss, S. [Gas Technology Inst., Des Plaines, IL (United States)

    2015-11-05

    "9Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

  11. Relevance of passive safety testing at the fast flux test facility to advanced liquid metal reactors - 5127

    International Nuclear Information System (INIS)

    Wootan, D.W.; Omberg, R.P.

    2015-01-01

    Significant cost and safety improvements can be realized in advanced liquid metal reactor (LMR) designs by emphasizing inherent or passive safety through crediting the beneficial reactivity feedbacks associated with core and structural movement. This passive safety approach was adopted for the Fast Flux Test Facility (FFTF), and an experimental program was conducted to characterize the structural reactivity feedback. Testing at the Rapsodie and EBR-II reactors had demonstrated the beneficial effect of reactivity feedback caused by changes in fuel temperature and core geometry mechanisms in a liquid metal fast reactor in a holistic sense. The FFTF passive safety testing program was developed to examine how specific design elements influenced dynamic reactivity feedback in response to a reactivity input and to demonstrate the scalability of reactivity feedback results from smaller cores like Rapsodie and EBR-II to reactor cores that were more prototypic in scale to reactors of current interest. The U.S. Department of Energy, Office of Nuclear Energy Advanced Reactor Technology program is in the process of preserving, protecting, securing, and placing in electronic format information and data from the FFTF, including the core configurations and data collected during the passive safety tests. Evaluation of these actual test data could provide insight to improve analytical methods which may be used to support future licensing applications for LMRs. (authors)

  12. Advanced Test Reactor Safety Basis Upgrade Lessons Learned Relative to Design Basis Verification and Safety Basis Management

    International Nuclear Information System (INIS)

    G. L. Sharp; R. T. McCracken

    2004-01-01

    The Advanced Test Reactor (ATR) is a pressurized light-water reactor with a design thermal power of 250 MW. The principal function of the ATR is to provide a high neutron flux for testing reactor fuels and other materials. The reactor also provides other irradiation services such as radioisotope production. The ATR and its support facilities are located at the Test Reactor Area of the Idaho National Engineering and Environmental Laboratory (INEEL). An audit conducted by the Department of Energy's Office of Independent Oversight and Performance Assurance (DOE OA) raised concerns that design conditions at the ATR were not adequately analyzed in the safety analysis and that legacy design basis management practices had the potential to further impact safe operation of the facility.1 The concerns identified by the audit team, and issues raised during additional reviews performed by ATR safety analysts, were evaluated through the unreviewed safety question process resulting in shutdown of the ATR for more than three months while these concerns were resolved. Past management of the ATR safety basis, relative to facility design basis management and change control, led to concerns that discrepancies in the safety basis may have developed. Although not required by DOE orders or regulations, not performing design basis verification in conjunction with development of the 10 CFR 830 Subpart B upgraded safety basis allowed these potential weaknesses to be carried forward. Configuration management and a clear definition of the existing facility design basis have a direct relation to developing and maintaining a high quality safety basis which properly identifies and mitigates all hazards and postulated accident conditions. These relations and the impact of past safety basis management practices have been reviewed in order to identify lessons learned from the safety basis upgrade process and appropriate actions to resolve possible concerns with respect to the current ATR safety

  13. Proof-testing strategies induced by dangerous detected failures of safety-instrumented systems

    International Nuclear Information System (INIS)

    Liu, Yiliu; Rausand, Marvin

    2016-01-01

    Some dangerous failures of safety-instrumented systems (SISs) are detected almost immediately by diagnostic self-testing as dangerous detected (DD) failures, whereas other dangerous failures can only be detected by proof-testing, and are therefore called dangerous undetected (DU) failures. Some items may have a DU- and a DD-failure at the same time. After the repair of a DD-failure is completed, the maintenance team has two options: to perform an insert proof test for DU-failure or not. If an insert proof test is performed, it is necessary to decide whether the next scheduled proof test should be postponed or performed at the scheduled time. This paper analyzes the effects of different testing strategies on the safety performance of a single channel of a SIS. The safety performance is analyzed by Petri nets and by approximation formulas and the results obtained by the two approaches are compared. It is shown that insert testing improves the safety performance of the channel, but the feasibility and cost of the strategy may be a hindrance to recommend insert testing. - Highlights: • Identify the tests induced by detected failures. • Model the testing strategies following DD-failures. • Propose analytical formulas for effects of strategies. • Simulate and verify the proposed models.

  14. Recent metal fuel safety tests in TREAT

    International Nuclear Information System (INIS)

    Wright, A.E.; Bauer, T.H.; Lo, R.K.; Robinson, W.R.; Palm, R.G.

    1986-01-01

    In-reactor safety tests have been performed on metal-alloy reactor fuel to study its response to transient-overpower conditions, in particular, the margin to cladding breach and the axial self-extrusion of fuel within intact cladding. Uranium-fissium EBR-II driver fuel elements of several burnups were tested, some to cladding breach and others to incipient breach. Transient fuel motions were monitored, and time and location of breach were measured. The test results and computations of fuel extrusion and cladding failure in metal-alloy fuel are described

  15. In-pile experiments and test facilities proposed for fast reactor safety

    International Nuclear Information System (INIS)

    Grolmes, M.A.; Avery, R.; Goldman, A.J.; Fauske, H.K.; Marchaterre, J.F.; Rose, D.; Wright, A.E.

    1976-01-01

    The role of in-pile experiments in support of the resolution of fast breeder reactor safety and licensing issues has been re-examined, with emphasis on key safety issues. Experiment needs have been related to the specific characteristics of these safety issues and to realistic requirements for additional test facility capabilities which can be achieved and utilized within the next ten years. It is found that those safety issues related to the energetics of core disruptive accidents have the largest impact on new facility requirements. However, utilization of existing facilities with modifications can provide for a continuing increase in experiment capability and experiment results on a timely bases. Emphasis has been placed upon maximum utilization of existing facilities and minimum requirements for new facilities. This evaluation has concluded that a new Safety Test Facility, STF, along with major modifications to the EBR II facility, improvement in TREAT capabilities, the existing Sodium Loop Safety Facility and corresponding Support Facilities provide the essential elements of the Safety Research Experiment Facilities (SAREF) required for resolution of key issues

  16. Observational Study on Safety of Prehospital BLS CPAP in Dyspnea.

    Science.gov (United States)

    Sahu, Novneet; Matthews, Patrick; Groner, Kathryn; Papas, Mia A; Megargel, Ross

    2017-12-01

    Introduction Continuous positive airway pressure (CPAP) improves outcomes in patients with respiratory distress. Additional benefits are seen with CPAP application in the prehospital setting. Theoretical safety concerns regarding Basic Life Support (BLS) providers using CPAP exist. In Delaware's (USA) two-tiered Emergency Medical Service (EMS) system, BLS often arrives before Advanced Life Support (ALS). Hypothesis This study fills a gap in literature by evaluating the safety of CPAP applied by BLS prior to ALS arrival. This was a retrospective, observational study using Quality Assurance (QA) data collected from October 2009 through December 2012 throughout a state BLS CPAP pilot program; CPAP training was provided to BLS providers prior to participation. Collected data include pulse-oximetry (spO2), respiratory rate (RR), heart rate (HR), skin color, and Glasgow Coma Score (GCS) before and after CPAP application. Pre-CPAP and post-CPAP values were compared using McNemar's and t-tests. Advanced practitioners evaluated whether CPAP was correctly applied and monitored and whether the patient condition was "improved," "unchanged," or "worsened." Seventy-four patients received CPAP by BLS; CPAP was correctly indicated and applied for all 74 patients. Respiratory status and CPAP were appropriately monitored and documented in the majority of cases (98.6%). A total of 89.2% of patients improved and 4.1% worsened; CPAP significantly reduced the proportion of patients with SpO224, and cyanosis (PCPAP (mean difference [MD]=0.17; 95% CI, -0.49 to 0.83; P=.59). The HR decreased from 115.7 (SD=53) to 105.1 (SD=37) after CPAP (MD=-10.9; 95% CI, -3.2 to -18.6; PCPAP (MD=17.8; 95% CI, 14.2-21.5; PCPAP was indicated, to apply it correctly, and to appropriately monitor the status of these patients. The majority of patients who received CPAP by BLS providers had improvement in their clinical status and vital signs. The findings suggest that CPAP can be safely used by BLS providers

  17. Safety testing for LHC access system

    CERN Document Server

    Valentini, F; Ninin, P; Scibile, S

    2008-01-01

    In the domain of Safety Real-Time Systems the problem of testing represents always a big effort in terms of time, costs and efficiency to guarantee an adequate coverage degree. Exhaustive tests may, in fact, not be practicable for large and distributed systems. This paper describes the testing process followed during the validation of the CERN's LHC Access System [1], responsible for monitoring and preventing physical risks for the personnel accessing the underground areas. In the paper we also present a novel strategy for the testing problem, intended to drastically reduce the time for the test patterns generation and execution. In particular, we propose a methodology for blackbox testing that relies on the application of Model Checking techniques. Model Checking is a formal method from computer science, commonly adopted to prove correctness of system’s models through an automatic system’s state space exploration against some property formulas.

  18. Evaluation of neutronic characteristics of in-pile test reactor for fast reactor safety research

    Energy Technology Data Exchange (ETDEWEB)

    Uto, N.; Ohno, S.; Kawata, N. [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1996-09-01

    An extensive research program has been carried out at the Power Reactor and Nuclear Fuel Development Corporation for the safety of future liquid-metal fast breeder reactors to be commercialized. A major part of this program is investigation and planning of advanced safety experiments conducted with a new in-pile safety test facility, which is larger and more advanced than any of the currently existing test reactors. Such a transient safety test reactor generally has unique neutronic characteristics that require various studies from the reactor physics point of view. In this paper, the outcome of the neutronics study is highlighted with presenting a reference core design concept and its performance in regard to the safety test objectives. (author)

  19. Oligonucleotide-based pharmaceuticals: Non-clinical and clinical safety signals and non-clinical testing strategies.

    Science.gov (United States)

    Mustonen, Enni-Kaisa; Palomäki, Tiina; Pasanen, Markku

    2017-11-01

    Antisense oligonucleotides, short interfering RNAs (siRNAs) and aptamers are oligonucleotide-based pharmaceuticals with a promising role in targeted therapies. Currently, five oligonucleotide-based pharmaceuticals have achieved marketing authorization in Europe or USA and many more are undergoing clinical testing. However, several safety concerns have been raised in non-clinical and clinical studies. Oligonucleotides share properties with both chemical and biological pharmaceuticals and therefore they pose challenges also from the regulatory point of view. We have analyzed the safety data of oligonucleotides and evaluated the applicability of current non-clinical toxicological guidelines for assessing the safety of oligonucleotide-based pharmaceuticals. Oligonucleotide-based pharmaceuticals display a similar toxicological profile, exerting adverse effects on liver and kidney, evoking hematological alterations, as well as causing immunostimulation and prolonging the coagulation time. It is possible to extrapolate some of these effects from non-clinical studies to humans. However, evaluation strategies for genotoxicity testing of "non-natural" oligonucleotides should be revised. Additionally, the selective use of surrogates and prediction of clinical endpoints for non-clinically observed immunostimulation is complicated by its multiple potential manifestations, demanding improvements in the testing strategies. Utilizing more relevant and mechanistic-based approaches and taking better account of species differences, could possibly improve the prediction of relevant immunological/proinflammatory effects in humans. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Regulatory and extra-regulatory testing to demonstrate radioactive material packaging safety

    International Nuclear Information System (INIS)

    Ammerman, D.J.

    1997-01-01

    Packages for the transportation of radioactive material must meet performance criteria to assure safety and environmental protection. The stringency of the performance criteria is based on the degree of hazard of the material being transported. Type B packages are used for transporting large quantities of radioisotopes (in terms of A 2 quantities). These packages have the most stringent performance criteria. Material with less than an A 2 quantity are transported in Type A packages. These packages have less stringent performance criteria. Transportation of LSA and SCO materials must be in open-quotes strong-tightclose quotes packages. The performance requirements for the latter packages are even less stringent. All of these package types provide a high level of safety for the material being transported. In this paper, regulatory tests that are used to demonstrate this safety will be described. The responses of various packages to these tests will be shown. In addition, the response of packages to extra-regulatory tests will be discussed. The results of these tests will be used to demonstrate the high level of safety provided to workers, the public, and the environment by packages used for the transportation of radioactive material

  1. Cyber Security Penetration Test for Digital Safety I and C Systems

    International Nuclear Information System (INIS)

    Lee, C. K.; Kim, D. H.; Kwon, K. C.; Joo, H. K.; Song, J. S.

    2010-01-01

    In the Korea Nuclear I and C Systems Development project the platforms for plant protection systems are developed, which function as a reactor shutdown, actuation of engineered safety features and a control of the related equipment. Those are fully digitalized through the use of safety-grade programmable logic controllers (PLCs) and few types of communication network. However the Regulatory Guide 1.152 (Rev. 02) was published by the U.S. NRC in 2006 and it recommended the application of a cyber security to the safety systems in the Nuclear Power Plant (NPP). Therefore to incorporate the new licensing requirement, a cyber security risk assessment is performed for the platforms. Then the vulnerabilities identified by the risk assessment are validated by penetration test. This paper summarizes test scenario, test results and their incorporation into system design

  2. Work stress and patient safety: observer-rated work stressors as predictors of characteristics of safety-related events reported by young nurses.

    Science.gov (United States)

    Elfering, A; Semmer, N K; Grebner, S

    This study investigates the link between workplace stress and the 'non-singularity' of patient safety-related incidents in the hospital setting. Over a period of 2 working weeks 23 young nurses from 19 hospitals in Switzerland documented 314 daily stressful events using a self-observation method (pocket diaries); 62 events were related to patient safety. Familiarity of safety-related events and probability of recurrence, as indicators of non-singularity, were the dependent variables in multilevel regression analyses. Predictor variables were both situational (self-reported situational control, safety compliance) and chronic variables (job stressors such as time pressure, or concentration demands and job control). Chronic work characteristics were rated by trained observers. The most frequent safety-related stressful events included incomplete or incorrect documentation (40.3%), medication errors (near misses 21%), delays in delivery of patient care (9.7%), and violent patients (9.7%). Familiarity of events and probability of recurrence were significantly predicted by chronic job stressors and low job control in multilevel regression analyses. Job stressors and low job control were shown to be risk factors for patient safety. The results suggest that job redesign to enhance job control and decrease job stressors may be an important intervention to increase patient safety.

  3. Environmental safety evaluation in test sea disposal of low-level radioactive wastes

    International Nuclear Information System (INIS)

    1979-01-01

    The study results on the environmental safety in the test sea disposal of low-level wastes by Subcommittee on Radioactive Waste Safety Technology in Nuclear Safety Commission are given in connection with the test disposal of radioactive wastes into sea reported by the Nuclear Safety Bureau. The Subcommittee concludes that the effect of the test disposal of radioactive wastes into sea on the environment is extremely small. The contents are as follows. The full text of the report; attached data, (1) prediction of the concentrations of radioactive nuclides in sea, (2) calculation of the concentrations of radioactive nuclides in marine life with biological paths, and (3) estimation of exposure dose in general people; references (1) radiation exposure of the personnel engaged in sea disposal, (2) the effect of a sea disaster during ocean transport. (J.P.N.)

  4. Fire Safety Tests for Spherical Resorcinol Formaldehyde Resin: Data Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-Sang; Peterson, Reid A.; Schweiger, Michael J.

    2012-07-30

    A draft safety evaluation of the scenario for spherical resorcinol-formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping, which may be overly bounding based on the fire performance data from the manufacturer of the ion exchange resin selected for use at the WTP. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI), following the American Society for Testing and Materials (ASTM) standard procedures, through a subcontract managed by Pacific Northwest National Laboratory (PNNL). For some tests, the ASTM standard procedures were not entirely appropriate or practical for the SRF resin material, so the procedures were modified and deviations from the ASTM standard procedures were noted. This report summarizes the results of fire safety tests performed and reported by SwRI. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. All as-received SwRI reports are attached to this report in the Appendix. Where applicable, the precision and bias of each test method, as given by each ASTM standard procedure, are included and compared with the SwRI test results of the SRF resin.

  5. An overview of FFTF [Fast Flux Test Facility] contributions to Liquid Metal Reactor Safety

    International Nuclear Information System (INIS)

    Waltar, A.E.; Padilla, A. Jr.

    1990-11-01

    The Fast Flux Test Facility has provided a very useful framework for testing the advances in Liquid Metal Reactor Safety Technology. During the licensing phase, the switch from a nonmechanistic bounding technique to the mechanistic approach was developed and implemented. During the operational phase, the consideration of new tests and core configurations led to use of the anticipated-transients-without-scram approach for beyond design basis events and the move towards passive safety. The future role of the Fast Flux Test Facility may involve additional passive safety and waste transmutation tests. 26 refs

  6. Recommendations for safety testing with the in vivo comet assay.

    Science.gov (United States)

    Vasquez, Marie Z

    2012-08-30

    While the in vivo comet assay increases its role in regulatory safety testing, deliberations about the interpretation of comet data continue. Concerns can arise regarding comet assay publications with limited data from non-blind testing of positive control compounds and using protocols (e.g. dose concentrations, sample times, and tissues) known to give an expected effect. There may be a tendency towards bias when the validation or interpretation of comet assay data is based on results generated by widely accepted but non-validated assays. The greatest advantages of the comet assay are its sensitivity and its ability to detect genotoxicity in tissues and at sample times that could not previously be evaluated. Guidelines for its use and interpretation in safety testing should take these factors into account. Guidelines should be derived from objective review of data generated by blind testing of unknown compounds dosed at non-toxic concentrations and evaluated in a true safety-testing environment, where the experimental design and conclusions must be defensible. However, positive in vivo comet findings with such compounds are rarely submitted to regulatory agencies and this data is typically unavailable for publication due to its proprietary nature. To enhance the development of guidelines for safety testing with the comet assay, and with the permission of several sponsors, this paper presents and discusses relevant data from multiple GLP comet studies conducted blind, with unknown pharmaceuticals and consumer products. Based on these data and the lessons we have learned through the course of conducting these studies, I suggest significant adjustments to the current conventions, and I provide recommendations for interpreting in vivo comet assay results in situations where risk must be evaluated in the absence of carcinogenicity or clinical data. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Safety demonstration test on solvent fire in fuel reprocessing plant

    International Nuclear Information System (INIS)

    Nishio, Gunji; Hashimoto, Kazuichiro

    1989-03-01

    This report summarizes a fundamental of results obtained in the Reprocessing Plant Safety Demonstration Test Program which was performed under the contract between the Science and Technology Agency of Japan and the Japan Atomic Energy Research Institute. In this test program, a solvent fire was hypothesized, and such data were obtained as fire behavior, smoke behavior and integrity of exhaust filters in the ventilation system. Through the test results, it was confirmed that under the fire condition in hypothetical accident, the integrity of the cell and the cell ventilation system were maintained, and the safety function of the exhaust filters was maintained against the smoke loading. Analytical results by EVENT code agreed well with the present test data on the thermofluid flow in a cell ventilation system. (author)

  8. Performance Test Results of Safety I and C Systems of SMART MMIS

    International Nuclear Information System (INIS)

    Suh, Yong Suk; Keum, Jong Yong; Jeong, Kwang Il; Lee, Joon Ku; Lee, Sang Seok; Kim, Kwan Woong

    2011-01-01

    KAERI has developed SMART (System-integrated Modular Advanced ReacTor), a 330MWt integral pressurized light water reactor that integrates four reactor coolant pumps, one pressurizer, eight steam generators, and one reactor core into a reactor vessel, since 1997 and submitted a SSAR (Standard design Safety Analysis Report) to Korea institute of nuclear safety (KINS) at the end of 2010 for the purpose of achieving the standard design approval (SDA) by the end of 2011. SMART MMIS has been designed with fully digitalized systems. Non-safety instrumentation and control (I and C) systems are designed based on the commercial distributed control systems. The safety I and C systems are designed using a new platform that was developed and validated by KAERI. Safety I and C systems are modularized using the platform. In the protection systems (PSs), datalinks are used to transmit data in a one-way direction in order to meet the independency requirement. In the engineered safety features-component control system (ESF-CCS), network switch devices (NSDs) are used to connect the group and loop controllers. The NSD was also newly developed and validated by KAERI. After validating the platform and NSD, a test facility was developed using the platform and NSDs to validate the performance of safety I and C systems. This paper presents the development and test results from the test facility

  9. Cyber Security Test Strategy for Non-safety Display System

    International Nuclear Information System (INIS)

    Son, Han Seong; Kim, Hee Eun

    2016-01-01

    Cyber security has been a big issue since the instrumentation and control (I and C) system of nuclear power plant (NPP) is digitalized. A cyber-attack on NPP should be dealt with seriously because it might cause not only economic loss but also the radioactive material release. Researches on the consequences of cyber-attack onto NPP from a safety point of view have been conducted. A previous study shows the risk effect brought by initiation of event and deterioration of mitigation function by cyber terror. Although this study made conservative assumptions and simplifications, it gives an insight on the effect of cyber-attack. Another study shows that the error on a non-safety display system could cause wrong actions of operators. According to this previous study, the failure of the operator action caused by a cyber-attack on a display system might threaten the safety of the NPP by limiting appropriate mitigation actions. This study suggests a test strategy focusing on the cyber-attack on the information and display system, which might cause the failure of operator. The test strategy can be suggested to evaluate and complement security measures. Identifying whether a cyber-attack on the information and display system can affect the mitigation actions of operator, the strategy to obtain test scenarios is suggested. The failure of mitigation scenario is identified first. Then, for the test target in the scenario, software failure modes are applied to identify realistic failure scenarios. Testing should be performed for those scenarios to confirm the integrity of data and to assure effectiveness of security measures

  10. Cyber Security Test Strategy for Non-safety Display System

    Energy Technology Data Exchange (ETDEWEB)

    Son, Han Seong [Joongbu University, Geumsan (Korea, Republic of); Kim, Hee Eun [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    Cyber security has been a big issue since the instrumentation and control (I and C) system of nuclear power plant (NPP) is digitalized. A cyber-attack on NPP should be dealt with seriously because it might cause not only economic loss but also the radioactive material release. Researches on the consequences of cyber-attack onto NPP from a safety point of view have been conducted. A previous study shows the risk effect brought by initiation of event and deterioration of mitigation function by cyber terror. Although this study made conservative assumptions and simplifications, it gives an insight on the effect of cyber-attack. Another study shows that the error on a non-safety display system could cause wrong actions of operators. According to this previous study, the failure of the operator action caused by a cyber-attack on a display system might threaten the safety of the NPP by limiting appropriate mitigation actions. This study suggests a test strategy focusing on the cyber-attack on the information and display system, which might cause the failure of operator. The test strategy can be suggested to evaluate and complement security measures. Identifying whether a cyber-attack on the information and display system can affect the mitigation actions of operator, the strategy to obtain test scenarios is suggested. The failure of mitigation scenario is identified first. Then, for the test target in the scenario, software failure modes are applied to identify realistic failure scenarios. Testing should be performed for those scenarios to confirm the integrity of data and to assure effectiveness of security measures.

  11. Safety evaluation report. Fast Flux Test Facility. Project No. 448

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-01

    Information on the safety of the FFTF Reactor is presented under the following chapter headings: site characteristics; design of structures, components, equipment, and systems; reactor; reactor coolant system and connected systems; engineered safety features; electric power; auxiliary systems; radioactive waste management systems; radiation protection; conduct of operations; initial test programs; accident analysis; and quality assurance.

  12. Safety evaluation report. Fast Flux Test Facility. Project No. 448

    International Nuclear Information System (INIS)

    1978-01-01

    Information on the safety of the FFTF Reactor is presented under the following chapter headings: site characteristics; design of structures, components, equipment, and systems; reactor; reactor coolant system and connected systems; engineered safety features; electric power; auxiliary systems; radioactive waste management systems; radiation protection; conduct of operations; initial test programs; accident analysis; and quality assurance

  13. Safety tests file

    International Nuclear Information System (INIS)

    2011-01-01

    The design and operation of nuclear power plants is governed by strict and clearly defined regulations designed to ensure their safety in all circumstances. Since the first nuclear reactors were commissioned, the basic safety principles and the corresponding practical requirements have constantly evolved and been enhanced, benefiting from operating experience feedback from reactors around the world (about 500 production reactors currently in service). Reactor safety has from the outset been built around the 'defense in depth' concept, which aims to prevent melting of the core and radioactive releases into the environment. It can be summarized as follows: over and above all the measures taken to prevent accidents, the principle that accidents do occur has to be accepted. We then assess their consequences and take steps to contain them at the level of severity at which they occur. (authors)

  14. 78 FR 25488 - Qualification Tests for Safety-Related Actuators in Nuclear Power Plants

    Science.gov (United States)

    2013-05-01

    ... Nuclear Power Plants AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory guide; request for... regulatory guide (DG), DG-1235, ``Qualification Tests for Safety-Related Actuators in Nuclear Power Plants... entitled ``Qualification Tests for Safety-Related Actuators in Nuclear Power Plants'' is temporarily...

  15. Thermal hydraulic tests for reactor safety system -Research on the improvement of nuclear safety-

    International Nuclear Information System (INIS)

    Chung, Moon Ki; Park, Chun Kyeong; Yang, Seon Kyu; Chung, Chang Hwan; Chun, Shee Yeong; Song, Cheol Hwa; Chun, Hyeong Gil; Chang, Seok Kyu; Chung, Heung Joon; Won, Soon Yeon; Cho, Yeong Ro; Kim, Bok Deuk; Min, Kyeong Ho

    1994-07-01

    The present research aims at the development of the thermal hydraulic verification test technology for the reactor safety system of the conventional and advanced nuclear power plant and the development of the advanced thermal hydraulic measuring techniques. (Author)

  16. Safety modelling and testing of lithium-ion batteries in electrified vehicles

    Science.gov (United States)

    Deng, Jie; Bae, Chulheung; Marcicki, James; Masias, Alvaro; Miller, Theodore

    2018-04-01

    To optimize the safety of batteries, it is important to understand their behaviours when subjected to abuse conditions. Most early efforts in battery safety modelling focused on either one battery cell or a single field of interest such as mechanical or thermal failure. These efforts may not completely reflect the failure of batteries in automotive applications, where various physical processes can take place in a large number of cells simultaneously. In this Perspective, we review modelling and testing approaches for battery safety under abuse conditions. We then propose a general framework for large-scale multi-physics modelling and experimental work to address safety issues of automotive batteries in real-world applications. In particular, we consider modelling coupled mechanical, electrical, electrochemical and thermal behaviours of batteries, and explore strategies to extend simulations to the battery module and pack level. Moreover, we evaluate safety test approaches for an entire range of automotive hardware sets from cell to pack. We also discuss challenges in building this framework and directions for its future development.

  17. Safety Assessment for transient event occurred during the ASTS test of Hanbit Unit 2

    International Nuclear Information System (INIS)

    Yang, Changkeun; Kim, Yohan; Ha, Sangjun

    2014-01-01

    Safety Injection has been actuated during the ASTS (Automatic Seismic Trip System) test of Hanbit Unit 2 on Feb. 28, 2014. It could be bad effect on system integrity. KHNP has been performed safety assessment of system for effect of Safety Injection (SI) actuation occurred during the ASTS test of hanbit Unit 2. Stable state of nuclear power plant system has been confirmed according to Safety Injection and reactor trip event occurred during the ASTS test of hanbit Unit 2. In the result of system safety assessment, major variables of nuclear power plant are located in optimal range and not exceed safety limit. It remains nuclear fuel and the integrity of the power plant is in a safe condition were conformed. After ASTS action, thermal elimination has been processed throughout the turbine until turbine signal occurrence because ASTS is connected to M-G set in the present hanbit Unit 2. Therefore, Safety Injection signal has been actuated by rapid reduction of Steam Generator pressure. In this paper, it is concluded that consideration of equipment and setpoint is needed for that Safety Injection has been not occurred under the unnecessary situation. Stable state of nuclear power plant system has been confirmed for Safety Injection and reactor trip event occurred during the ASTS test of hanbit Unit 2. In the result of system safety assessment, major variables of nuclear power plant are located in optimal range and not exceed safety limit. It remains nuclear fuel and the integrity of the plant is in a safe condition were conformed. It is concluded that consideration of equipment and setpoint is needed for that Safety Injection has been not occurred under the unnecessary situation

  18. Supplementary safety system 1/4 scale testing

    Energy Technology Data Exchange (ETDEWEB)

    Garrett, R.L.; Paik, I.K.

    1993-09-01

    During the course of updating the K-Reactor Safety Analysis Report Chapter 15 in 1990, it was identified that the current Supplementary Safety System (SSS) may not be adequate in protecting the reactor during the process water pump coastdown initiated by a loss of AC power when the safety rods are assumed to fail. A SSS modification project was initiated to add an additional ink injection pathway near the pump suction. In addition, the Department of Energy raised a question on the thermal buoyancy effects on moderator flow pattern and ink dispersion in the moderator space. The development and documentation of a two-dimensional code called MODFLOW was undertaken to describe the problem. This report discusses the results of the moderator flow and ink (Gadolinium Poison Solution - GPS) dispersion tests designed to provide qualified data for validation and benchmarking of the MODFLOW computer code with the secondary objectives being the development of concentration profiles and video footage of simulated GPS dispersion under steady-state and transient flow conditions.

  19. Impact of proof test interval and coverage on probability of failure of safety instrumented function

    International Nuclear Information System (INIS)

    Jin, Jianghong; Pang, Lei; Hu, Bin; Wang, Xiaodong

    2016-01-01

    Highlights: • Introduction of proof test coverage makes the calculation of the probability of failure for SIF more accurate. • The probability of failure undetected by proof test is independently defined as P TIF and calculated. • P TIF is quantified using reliability block diagram and simple formula of PFD avg . • Improving proof test coverage and adopting reasonable test period can reduce the probability of failure for SIF. - Abstract: Imperfection of proof test can result in the safety function failure of safety instrumented system (SIS) at any time in its life period. IEC61508 and other references ignored or only elementarily analyzed the imperfection of proof test. In order to further study the impact of the imperfection of proof test on the probability of failure for safety instrumented function (SIF), the necessity of proof test and influence of its imperfection on system performance was first analyzed theoretically. The probability of failure for safety instrumented function resulted from the imperfection of proof test was defined as probability of test independent failures (P TIF ), and P TIF was separately calculated by introducing proof test coverage and adopting reliability block diagram, with reference to the simplified calculation formula of average probability of failure on demand (PFD avg ). Research results show that: the shorter proof test period and the higher proof test coverage indicate the smaller probability of failure for safety instrumented function. The probability of failure for safety instrumented function which is calculated by introducing proof test coverage will be more accurate.

  20. Results of the 1986 FFTF inherent safety tests

    International Nuclear Information System (INIS)

    Burke, T.M.; Campbell, L.R.; Franz, G.R.; Knecht, W.L.

    1987-01-01

    A series of tests was recently completed at the 400-MW (thermal) Fast Flux Test Facility (FFTF) to further demonstrate the passive safety characteristics of liquid-metal-cooled fast reactors. Earlier FFTF testing of decay heat removal by sodium natural circulation was reported in 1981. The main purpose of the 1986 test series was to demonstrate passive reactor shutdown during a loss-of-flow event when several inherent shutdown devices called gas expansion modules (GEMs) were installed in the reactor. However, these tests also provide further data on the natural circulation performance of the primary system, in particular the reactor core, and thus add to the data base available for checking the validity of available analytical tools

  1. Social signals of safety and risk confer utility and have asymmetric effects on observers' choices.

    Science.gov (United States)

    Chung, Dongil; Christopoulos, George I; King-Casas, Brooks; Ball, Sheryl B; Chiu, Pearl H

    2015-06-01

    Individuals' risk attitudes are known to guide choices about uncertain options. However, in the presence of others' decisions, these choices can be swayed and manifest as riskier or safer behavior than one would express alone. To test the mechanisms underlying effective social 'nudges' in human decision-making, we used functional neuroimaging and a task in which participants made choices about gambles alone and after observing others' selections. Against three alternative explanations, we found that observing others' choices of gambles increased the subjective value (utility) of those gambles for the observer. This 'other-conferred utility' was encoded in ventromedial prefrontal cortex, and these neural signals predicted conformity. We further identified a parametric interaction with individual risk preferences in anterior cingulate cortex and insula. These data provide a neuromechanistic account of how information from others is integrated with individual preferences that may explain preference-congruent susceptibility to social signals of safety and risk.

  2. Status of the EU test blanket systems safety studies

    International Nuclear Information System (INIS)

    Panayotov, Dobromir; Poitevin, Yves; Ricapito, Italo; Zmitko, Milan

    2015-01-01

    Highlights: • TBS safety demonstration files. • Safety functions and related design features – detailed TBS components classifications. • Nuclear analyses, radiation shielding and protection. • TBS radiological waste management strategy and categorization. • Selection and definition of reference accidents scenarios and accidents analyses. - Abstract: The European joint undertaking for ITER and the development of fusion energy (‘Fusion for Energy’ – F4E) provides the European contributions to the ITER international fusion energy research project. Among others it includes also the development, design, technological demonstration and implementation of the European test blanket systems (TBS) in ITER. Currently two EU TBS designs are in the phase of conceptual design – helium-cooled lithium-lead (HCLL) and helium-cooled pebble-bed (HCPB). Safety demonstration is an important part of the work devoted to the achievement of the next key project milestone the conceptual design review. The paper reveals the details of the work on EU TBS safety performed in the last couple of years: update of the TBS safety demonstration files; safety functions and related design features; detailed TBS components classifications; nuclear analyses, radiation shielding and protection; TBS radiological waste management strategy and categorization; selection and definition of reference accidents scenarios, and accidents analyses. Finally the authors share the information on on-going and planned future EU TBS safety activities.

  3. Status of the EU test blanket systems safety studies

    Energy Technology Data Exchange (ETDEWEB)

    Panayotov, Dobromir, E-mail: dobromir.panayotov@f4e.europa.eu; Poitevin, Yves; Ricapito, Italo; Zmitko, Milan

    2015-10-15

    Highlights: • TBS safety demonstration files. • Safety functions and related design features – detailed TBS components classifications. • Nuclear analyses, radiation shielding and protection. • TBS radiological waste management strategy and categorization. • Selection and definition of reference accidents scenarios and accidents analyses. - Abstract: The European joint undertaking for ITER and the development of fusion energy (‘Fusion for Energy’ – F4E) provides the European contributions to the ITER international fusion energy research project. Among others it includes also the development, design, technological demonstration and implementation of the European test blanket systems (TBS) in ITER. Currently two EU TBS designs are in the phase of conceptual design – helium-cooled lithium-lead (HCLL) and helium-cooled pebble-bed (HCPB). Safety demonstration is an important part of the work devoted to the achievement of the next key project milestone the conceptual design review. The paper reveals the details of the work on EU TBS safety performed in the last couple of years: update of the TBS safety demonstration files; safety functions and related design features; detailed TBS components classifications; nuclear analyses, radiation shielding and protection; TBS radiological waste management strategy and categorization; selection and definition of reference accidents scenarios, and accidents analyses. Finally the authors share the information on on-going and planned future EU TBS safety activities.

  4. Safety measures for integrity test apparatus for IS process. Sulfuric acid decomposition section

    International Nuclear Information System (INIS)

    Noguchi, Hiroki; Kubo, Shinji; Iwatsuki, Jin; Onuki, Kaoru

    2013-07-01

    Hazardous substances such as sulfuric acid, sulfur dioxide and hydrogen iodide acid are employed in thermochemical Iodine-Sulfur (IS) process. It is necessary to take safety measure against workers and external environments to study experimentally on IS process. Presently we have been conducting to verify the soundness of main components made of engineering material in actual corrosive condition. An integrity test apparatus for the components of sulfuric acid decomposition was set up. We will use the hazardous substances such as sulfuric acid and sulfur dioxide and perform the experiment in pressurized condition in this integrity test. Safety measures for the test apparatus, operation and abnormal situation were considered prior to starting the test. This report summarized the consideration results for the safety measures on the integrity test apparatus for the components of sulfuric acid decomposition. (author)

  5. Safety and Environment- Masterplan 2020 of DLR's Rocket Test Center Lampoldhausen

    Science.gov (United States)

    Haberzettl, Andreas; Dommers, Michael

    2013-09-01

    The German Aerospace Center DLR is the German research institute with approximately 7000 employees in 16 domestic locations. Among the research priorities of the German Aerospace Center DLR includes aerospace, energy and transport. DLR is institutionally supported by federal and state governments.Next funding sources arise in the context of third-party funds business (contract research and public contracts and subsidiaries). Main activities of the test center Lampoldshausen are testing of ARIANE's main and upper stage engines in the frame of ESA contracts.In the last years the test center of the DLR in Lampoldshausen has grown strongly, so that the number of employees is actually of about 230. The testing department is mainly responsible for rocket combustion testing according to customer requirements.Two kinds of test facilities are operated, sea level test benches and the altitude simulation test facilities.In addition to the DLR's growth also the activities of the industrial partner ASTRIUM has been elevated so that actually nearly 600 employees are present on site Lampoldshausen.The management of the site in relation to safety and security requires special measures with special respect to the presence of more people inside the testing area in order to guarantee trouble-free and safe experimental operation onsite the DLR's test plants. In order to meet with the future needs of continuing growth, the security and safety requirements have to be adopted.This report gives comprehensive outlook information about future possible scenarios of our coming tasks.Main driving force for future requests is the evolution of the rocket ARIANE. The testing of the new upper stage test facility for ARIANE 5 midlife evolution has been started. A new test position P5.2 is foreseen to perform the qualification of the new upper stage with the VINCI engine. This project will be very complex, in parallel running operation processes will require special procedures related to the overall

  6. Safety test No. S-6, launch pad abort sequential test Phase II: solid propellant fire

    International Nuclear Information System (INIS)

    Snow, E.C.

    1975-08-01

    In preparation for the Lincoln Laboratory's LES 8/9 space mission, a series of tests was performed to evaluate the nuclear safety capability of the Multi-Hundred Watt (MHW) Radioisotope Thermoelectric Generator (RTG) to be used to supply power for the satellite. One such safety test is Test No. S-6, Launch Pad Abort Sequential Test. The objective of this test was to subject the RTG and its components to the sequential environments characteristic of a catastrophic launch pad accident to evaluate their capability to contain the 238 PuO 2 fuel. This sequence of environments was to have consisted of the blast overpressure and fragments, followed by the fireball, low velocity impact on the launch pad, and solid propellant fire. The blast overpressure and fragments were subsequently eliminated from this sequence. The procedures and results of Phase II of Test S-6, Solid Propellant Fire are presented. In this phase of the test, a simulant Fuel Sphere Assembly (FSA) and a mockup of a damaged Heat Source Assembly (HSA) were subjected to single proximity solid propellant fires of approximately 10-min duration. Steel was introduced into both tests to simulate the effects of launch pad debris and the solid rocket motor (SRM) casing that might be present in the fire zone. (TFD)

  7. Thermal-hydraulic tests for reactor safety system

    International Nuclear Information System (INIS)

    Chun, Se Young; Chung, Moon Ki; Baek, Won Pil

    2002-05-01

    Tests for the safety depressurization system, Sparger adopted for the Korean next generation reactor, APR1400 are carried out for several geometries with the B and C (Blowdown and Condensation) facility in the condition of high temperature and pressure and with a small test facility in the condition of atmospheric temperature and pressure. Tests for the critical heat flux are performed with the RCS(Reactor Coolant System) facility as well as with the Freon CHF Loop in the condition of high temperature and pressure. The atmospheric temperature and pressure facility is utilized for development of the high standard thermal hydraulic measurement technology. The optical method is developed to measure the local thermal-hydraulic behavior for the single and two-phase boiling phenomena

  8. Tests for validation of fast neutron reactors safety

    International Nuclear Information System (INIS)

    Nagata, T.; Yamashita, H.

    2001-01-01

    Japanese scientific research and design enterprises in cooperation with industrial and power generating corporations implement a project on creating a fast neutron reactor of the ultimate safety. One of the basic expected results from such a development is creation of a reactor core structure that is able to eliminate recriticality occurrence in the course of reactor accident involving fuel melting. One of the possible ways to solve this problem is to include pipes (meant for specifying directed (controlled) molten fuel relocation) into fuel assembly structure. In the course of conduction and subsequent implementation of such a design the basic issue is to experimentally confirm the operating capacity of FA having such a structure and that is called FAIDUS. Within EAGLE Project on experimental basis of IAE NNC RK an activity has been started on preparation and conduction of out-of-pile and in-pile tests. During tests a sodium coolant will be used. Studies are conducted by NNC RK in cooperation with the Japanese corporations JAPC and JNC. Basic objective of out-of-pile tests was to obtain preliminary information on fuel relocation behavior under conditions simulating accident involving melting of core consisting of FAIDUS FA, which will help to clarify simulation criteria and to develop the most optimum structure of the experimental channel for reactor experiments conduction. The basic objective of in-pile tests was the experimental confirmation of operating capacity of FAIDUS FA model under reactor conditions. According to the program two tests are planned to be performed at IGR reactor: tests for validation of fast neutron reactor safety, and out-of-pile tests at EAGLE experimental facility without sodium coolant

  9. A Test Suite for Safety-Critical Java using JML

    DEFF Research Database (Denmark)

    Ravn, Anders Peter; Søndergaard, Hans

    2013-01-01

    Development techniques are presented for a test suite for the draft specification of the Java profile for Safety-Critical Systems. Distinguishing features are: specification of conformance constraints in the Java Modeling Language, encoding of infrastructure concepts without implementation bias......, and corresponding specifications of implicitly stated behavioral and real-time properties. The test programs are auto-generated from the specification, while concrete values for test parameters are selected manually. The suite is open source and publicly accessible....

  10. Potential safety enhancements to nuclear plant control: proof testing at EBR-II

    International Nuclear Information System (INIS)

    Lindsay, R.W.; Chisholm, G.H.

    1984-01-01

    Future changes in nuclear plant control and protective systems will reflect an evolutionary improvement through increased use of computers coupled with a better integration of man and machine. Before improvements can be accepted into the licensed commercial plant environment, significant testing must be accomplished to answer safety questions and to prove the worth of new ideas. The Experimental Breeder Reactor-II (EBR-II) is being used as a test-bed for both in-house development and testing for others in a DOE sponsored Man-Machine Integration program. The ultimate result of the development and testing would be a control system for which safety credit could be taken in the licensing process

  11. Observability-in-depth: An essential complement to the defense-in-depth safety strategy in the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Favaro, Francesca M.; Saleh, Joseph H. [Georgia Institute of Technology, Atlanta (United States)

    2014-12-15

    Defense-in-depth is a fundamental safety principle for the design and operation of nuclear power plants. Despite its general appeal, defense-in-depth is not without its drawbacks, which include its potential for concealing the occurrence of hazardous states in a system, and more generally rendering the latter more opaque for its operators and managers, thus resulting in safety blind spots. This in turn translates into a shrinking of the time window available for operators to identify an unfolding hazardous condition or situation and intervene to abate it. To prevent this drawback from materializing, we propose propose in this work a novel safety principle termed 'observability-in-depth'. We characterize it as the set of provisions technical, operational, and organizational designed to enable the monitoring and identification of emerging hazardous conditions and accident pathogens in real-time and over different time-scales. Observability-in-depth also requires the monitoring of conditions of all safety barriers that implement defense-in-depth; and in so doing it supports sense making of identified hazardous conditions, and the understanding of potential accident sequences that might follow (how they can propagate). Observability-in-depth is thus an information-centric principle, and its importance in accident prevention is in the value of the information it provides and actions or safety interventions it spurs. We examine several 'event reports' from the U.S. Nuclear Regulatory Commission database, which illustrate specific instances of violation of the observability-in-depth safety principle and the consequences that followed (e.g., unmonitored releases and loss of containments). We also revisit the Three Mile Island accident in light of the proposed principle, and identify causes and consequences of the lack of observability-in-depth related to this accident sequence. We illustrate both the benefits of adopting the observability

  12. NRC confirmatory safety system testing in support of AP600 design review

    International Nuclear Information System (INIS)

    Rhee, G.S.; Bessette, D.E.; Shotkin, L.M.

    1994-01-01

    Westinghouse Electric Corporation has submitted the Advanced Passive 600 MWe (AP600) nuclear power plant design to the NRC for design certification. The Office of Nuclear Regulatory Research is proceeding to conduct confirmatory testing to help the NRC staff evaluate the AP600 safety system design. For confirmatory testing, it was determined that the cost-effective route was to modify an existing full-height, full-pressure test facility rather than build a new one. Thus, all the existing integral effects test facilities, both in the US and abroad, were screened to select the best candidate. As a result, the ROSA-V (Rig of Safety Assessment-V) test facility located in the Japan Atomic Energy Research Institute (JAERI) was chosen. However, because of some differences in design between the existing ROSA-V facility and the AP600, the ROSA-V is being modified to conform to the AP600 safety system design. The modification work will be completed by the end of this year. A series of facility characterization tests will then be performed in January 1994 for the modified part of the facility before the main test series is initiated in February 1994. A total of 12 tests will be performed in 1994 under Phase I of this cooperative program with JAERI. Phase II testing is being considered to be conducted in 1995 mainly for beyond-design-basis accident evaluation

  13. 77 FR 10666 - Pipeline Safety: Post Accident Drug and Alcohol Testing

    Science.gov (United States)

    2012-02-23

    ... 199 [Docket No. PHMSA-2011-0335] Pipeline Safety: Post Accident Drug and Alcohol Testing AGENCY... operators of Liquefied Natural Gas (LNG) facilities to conduct post- accident drug and alcohol tests of..., operators must drug and alcohol test each covered employee whose performance either contributed to the...

  14. Results and implications of the EBR-II inherent safety demonstration tests

    International Nuclear Information System (INIS)

    Planchon, H.P.; Golden, G.H.; Sackett, J.I.; Mohr, D.; Chang, L.K.; Feldman, E.E.; Betten, P.R.

    1987-01-01

    On April 3, 1986 two milestone tests were conducted in Experimental Breeder Reactor-2 (EBR-II). The first test was a loss of flow without scram and the second was a loss of heat sink without scram. Both tests were initiated from 100% power and in both tests the reactor was shut down by natural processes, principally thermal expansion, without automatic scram, operator intervention or the help of special in-core devices. The temperature transients during the tests were mild, as predicted, and there was no damage to the core or reactor plant structures. In a general sense, therefore, the tests plus supporting analysis demonstrated the feasibility of inherent passive shutdown for undercooling accidents in metal-fueled LMRs. The results provide a technical basis for future experiments in EBR-II to demonstrate inherent safety for overpower accidents and provide data for validation of computer codes used for design and safety analysis of inherently safe reactor plants

  15. Field Test of the World Health Organization Multi-Professional Patient Safety Curriculum Guide

    Science.gov (United States)

    Farley, Donna; Zheng, Hao; Rousi, Eirini; Leotsakos, Agnès

    2015-01-01

    Introduction Although the importance of training in patient safety has been acknowledged for over a decade, it remains under-utilized and under-valued in most countries. WHO developed the Multi-professional Patient Safety Curriculum Guide to provide schools with the requirements and tools for incorporating patient safety in education. It was field tested with 12 participating schools across the six WHO regions, to assess its effectiveness for teaching patient safety to undergraduate and graduate students in a global variety of settings. Methods The evaluation used a combined prospective/retrospective design to generate formative information on the experiences of working with the Guide and summative information on the impacts of the Guide. Using stakeholder interviews and student surveys, data were gathered from each participating school at three times: the start of the field test (baseline), soon after each school started teaching, and soon after each school finished teaching. Results Stakeholders interviewed were strongly positive about the Guide, noting that it emphasized universally important patient safety topics, was culturally appropriate for their countries, and gave credibility and created a focus on patient safety at their schools. Student perceptions and attitudes regarding patient safety improved substantially during the field test, and their knowledge of the topics they were taught doubled, from 10.7% to 20.8% of correct answers on the student survey. Discussion This evaluation documented the effectiveness of the Curriculum Guide, for both ease of use by schools and its impacts on improving the patient safety knowledge of healthcare students. WHO should be well positioned to refine the contents of the Guide and move forward in encouraging broader use of the Guide globally for teaching patient safety. PMID:26406893

  16. Field Test of the World Health Organization Multi-Professional Patient Safety Curriculum Guide.

    Science.gov (United States)

    Farley, Donna; Zheng, Hao; Rousi, Eirini; Leotsakos, Agnès

    2015-01-01

    Although the importance of training in patient safety has been acknowledged for over a decade, it remains under-utilized and under-valued in most countries. WHO developed the Multi-professional Patient Safety Curriculum Guide to provide schools with the requirements and tools for incorporating patient safety in education. It was field tested with 12 participating schools across the six WHO regions, to assess its effectiveness for teaching patient safety to undergraduate and graduate students in a global variety of settings. The evaluation used a combined prospective/retrospective design to generate formative information on the experiences of working with the Guide and summative information on the impacts of the Guide. Using stakeholder interviews and student surveys, data were gathered from each participating school at three times: the start of the field test (baseline), soon after each school started teaching, and soon after each school finished teaching. Stakeholders interviewed were strongly positive about the Guide, noting that it emphasized universally important patient safety topics, was culturally appropriate for their countries, and gave credibility and created a focus on patient safety at their schools. Student perceptions and attitudes regarding patient safety improved substantially during the field test, and their knowledge of the topics they were taught doubled, from 10.7% to 20.8% of correct answers on the student survey. This evaluation documented the effectiveness of the Curriculum Guide, for both ease of use by schools and its impacts on improving the patient safety knowledge of healthcare students. WHO should be well positioned to refine the contents of the Guide and move forward in encouraging broader use of the Guide globally for teaching patient safety.

  17. The US Advanced Liquid Metal Reactor and the Fast Flux Test Facility Phase IIA passive safety tests

    International Nuclear Information System (INIS)

    Shen, P.K.; Harris, R.A.; Campbell, L.R.; Dautel, W.A.; Dubberley, A.E.; Gluekler, E.L.

    1992-07-01

    This report discusses the safety approach of the Advanced Liquid Metal reactor program, sponsored by the US Department of Energy, which relies upon passive reactor responses to off-normal condition to limit power and temperature excursions to levels that allow safety margins. Gas expansion modules (GEM) have included in the design to provide negative reactivity to enhance these margins in the extremely unlikely event that pumping power is lost and the highly reliable scram system fails to operate. The feasibility and beneficial features of these devices were first demonstrated in the core of the Fast Flux Test Facility (FFTF) in 1986. Preapplication safety evaluations by the US Nuclear Regulatory Commission have identified areas that must be addressed if these devices are to be relied on. One of these areas is the response of the reactor when it is critical and the pumps are turned on, resulting in positive reactivity being added to the core. Tests to examine such transients have been performed as part of the continuing FFTF program to confirm the passive safety characteristics of liquid metal reactors (LMR). The primary tests consisted of starting the main coolant pumps, which forced sodium coolant into the GEMS, decreasing neutron leakage and adding positive reactivity. The resulting transients were shown to be benign and easily mitigated by the reactivity feedbacks inherent in the FFTF and all LMRs. Steady-state auxiliary tests of the GEM and feedback reactivity worths accurately predicted the transient results. The auxiliary GEM worth tests also demonstrated that the worth can be determined at a subcritical state, which allows for a verification of the GEM's availability prior to ascending to power

  18. 76 FR 34145 - Safety Zone, Barrier Testing Operations, Chicago Sanitary and Ship Canal, Romeoville, IL

    Science.gov (United States)

    2011-06-13

    ...-AA00 Safety Zone, Barrier Testing Operations, Chicago Sanitary and Ship Canal, Romeoville, IL AGENCY.... Construction on Barrier IIB has been completed. Operational and safety testing was conducted in February 2011... dispersal barrier IIA and IIB. This safety zone will be enforced daily from 7 a.m. to 11 a.m. and from 1 p.m...

  19. Test Operations Procedure (TOP) 01-1-025 Camouflage Performance Testing Using Observers

    Science.gov (United States)

    2016-05-05

    one observer approaching the test article at a time, but these tests are time consuming and expensive to execute for collection of statistically...best data collection approach is live in the field using only one observer for each trial run but these tests are extremely time consuming and...with viewing angle, relative to the ground plane of the observation should be considered in the test design. The impact of aspect angle, such as

  20. Verification of Overall Safety Factors In Deterministic Design Of Model Tested Breakwaters

    DEFF Research Database (Denmark)

    Burcharth, H. F.

    2001-01-01

    The paper deals with concepts of safety implementation in design. An overall safety factor concept is evaluated on the basis of a reliability analysis of a model tested rubble mound breakwater with monolithic super structure. Also discussed are design load identification and failure mode limit...

  1. OBSERVABILITY-IN-DEPTH: AN ESSENTIAL COMPLEMENT TO THE DEFENSE-IN-DEPTH SAFETY STRATEGY IN THE NUCLEAR INDUSTRY1

    Directory of Open Access Journals (Sweden)

    FRANCESCA M. FAVARÒ

    2014-12-01

    We examine several “event reports” from the U.S. Nuclear Regulatory Commission database, which illustrate specific instances of violation of the observability-in-depth safety principle and the consequences that followed (e.g., unmonitored releases and loss of containments. We also revisit the Three Mile Island accident in light of the proposed principle, and identify causes and consequences of the lack of observability-in-depth related to this accident sequence. We illustrate both the benefits of adopting the observability-in-depth safety principle and the adverse consequences when this principle is violated or not implemented. This work constitutes a first step in the development of the observability-in-depth safety principle, and we hope this effort invites other researchers and safety professionals to further explore and develop this principle and its implementation.

  2. Standards for radiation protection instrumentation: design of safety standards and testing procedures

    International Nuclear Information System (INIS)

    Meissner, Frank

    2008-01-01

    This paper describes by means of examples the role of safety standards for radiation protection and the testing and qualification procedures. The development and qualification of radiation protection instrumentation is a significant part of the work of TUV NORD SysTec, an independent expert organisation in Germany. The German Nuclear Safety Standards Commission (KTA) establishes regulations in the field of nuclear safety. The examples presented may be of importance for governments and nuclear safety authorities, for nuclear operators and for manufacturers worldwide. They demonstrate the advantage of standards in the design of radiation protection instrumentation for new power plants, in the upgrade of existing instrumentation to nuclear safety standards or in the application of safety standards to newly developed equipment. Furthermore, they show how authorities may proceed when safety standards for radiation protection instrumentation are not yet established or require actualization. (author)

  3. Comparison of EPRI safety valve test data with analytically determined hydraulic results

    International Nuclear Information System (INIS)

    Smith, L.C.; Howe, K.S.

    1983-01-01

    NUREG-0737 (November 1980) and all subsequent U.S. NRC generic follow-up letters require that all operating plant licensees and applicants verify the acceptability of plant specific pressurizer safety valve piping systems for valve operation transients by testing. To aid in this verification process, the Electric Power Research Institute (EPRI) conducted an extensive testing program at the Combustion Engineering Test Facility. Pertinent tests simulating dynamic opening of the safety valves for representative upstream environments were carried out. Different models and sizes of safety valves were tested at the simulated operating conditions. Transducers placed at key points in the system monitored a variety of thermal, hydraulic and structural parameters. From this data, a more complete description of the transient can be made. The EPRI test configuration was analytically modeled using a one-dimensional thermal hydraulic computer program that uses the method of characteristics approach to generate key fluid parameters as a function of space and time. The conservative equations are solved by applying both the implicit and explicit characteristic methods. Unbalanced or wave forces were determined for each straight run of pipe bounded on each side by a turn or elbow. Blowdown forces were included, where appropriate. Several parameters were varied to determine the effects on the pressure, hydraulic forces and timings of events. By comparing these quantities with the experimentally obtained data, an approximate picture of the flow dynamics is arrived at. Two cases in particular are presented. These are the hot and cold loop seal discharge tests made with the Crosby 6M6 spring-loaded safety valve. Included in the paper is a description of the hydraulic code, modeling techniques and assumptions, a comparison of the numerical results with experimental data and a qualitative description of the factors which govern pipe support loading. (orig.)

  4. Demonstration tests for low level radioactive waste packaging safety

    International Nuclear Information System (INIS)

    Nagano, I.; Shimura, S.; Miki, T.; Tamamura, T.; Kunitomi, K.

    1993-01-01

    The transport packaging for low level radioactive waste (so-called the LLW packaging) has been developed to be utilized for transportation of LLW in 200 liter-drums from Japanese nuclear power stations to the LLW Disposal Center at Rokkashomura in Aomori Prefecture. Transportation is expected to start from December in 1992. We will explain the brief history of the development, technical features and specifications as well as two kinds of safety demonstration tests, namely one is '1.2 meter free drop test' and the other is 'ISO container standard test'. (J.P.N.)

  5. A Study on the Improvement of Safety Testing Standards and Methods for Mammography

    International Nuclear Information System (INIS)

    Choi, Seon Hyeong; Jung, Ah Young; Yong, Hwan Seok; Kim, Do Wan; Jang, Gi Won; Cha, Sang Hoon; Jo, Sang Won; Park, Ji Koon

    2012-01-01

    To establish the improved national safety testing standards and methods for mammography. We investigated and compared the current status of mammographic equipment installation with the national and international safety and quality control programs and methods. We established and verified the draft for safety testing standards and methods. We propose that the investigations of the conductor system, hardware leakage radiation profile, illumination intensity test, comparison between X-ray and light photon exposure, X-ray dose exposure on the chest wall, compression equipment size, timing equipment, and the average effective radiation dose, should all be maintained as they are in the present state without any changes. However, the exposure radiation dose reproducibility, kVp and mAs, and the half value layer tests should be reconsidered and revised. Moreover, compression pressure and autonomic exposure control system (AEC) tests should be included as new criteria. Other parameter controls included in the phantom image analysis which overlap with total quality assurance should be excluded. We recommend that AEC and compression pressure tests should be included as new criteria and the methods for the exposure radiation dose reproducibility, kVp, and mAs, and half value layer tests should be reconsidered and revised.

  6. Using partial safety factors in wind turbine design and testing

    Energy Technology Data Exchange (ETDEWEB)

    Musial, W.D. [National Renewable Energy Lab., Golden, CO (United States)

    1997-12-31

    This paper describes the relationship between wind turbine design and testing in terms of the certification process. An overview of the current status of international certification is given along with a description of limit-state design basics. Wind turbine rotor blades are used to illustrate the principles discussed. These concepts are related to both International Electrotechnical Commission and Germanischer Lloyd design standards, and are covered using schematic representations of statistical load and material strength distributions. Wherever possible, interpretations of the partial safety factors are given with descriptions of their intended meaning. Under some circumstances, the authors` interpretations may be subjective. Next, the test-load factors are described in concept and then related to the design factors. Using technical arguments, it is shown that some of the design factors for both load and materials must be used in the test loading, but some should not be used. In addition, some test factors not used in the design may be necessary for an accurate test of the design. The results show that if the design assumptions do not clearly state the effects and uncertainties that are covered by the design`s partial safety factors, outside parties such as test labs or certification agencies could impose their own meaning on these factors.

  7. Safety Test Report for the SNF Dry Storage System

    Energy Technology Data Exchange (ETDEWEB)

    Bang, K. S.; Seo, K. S.; Lee, J. H.; Lee, J. C.; Choi, W. S

    2008-11-15

    This is technical report conducted by KAERI under the contract with NETEC for safety test for the PWR S/F dry storage system. Leak Test was performed after drop test and turn-over test, the measured leakage rate was lower than allowable leakage rate. It is revealed that the containment integrity of the dry storage system is maintained. In the seismic test, the moving of the model was measured at SRTH seismic response of 0.4 g and 0.8 g. Therefore the seismic test results can be used fully to the test data for verification of the seismic analysis. In the thermal test, the direction of the inlet and outlet of the air has no effect on the heat transfer performance. The passive heat removal system of the horizontal storage module was designed well.

  8. Testing the performance of microbiological safety cabinets used in microbiology laboratories in South Korea.

    Science.gov (United States)

    Hwang, S H; Yi, T W; Cho, K H; Lee, I M; Yoon, C S

    2011-09-01

    To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high-efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Routine evaluation and maintenance of MSCs are critical for optimizing performance. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  9. [Non-animal toxicology in the safety testing of chemicals].

    Science.gov (United States)

    Heinonen, Tuula; Tähti, Hanna

    2013-01-01

    There is an urgent need to develop predictive test methods better than animal experiments for assessing the safety of chemical substances to man. According to today's vision this is achieved by using human cell based tissue and organ models. In the new testing strategy the toxic effects are assessed by the changes in the critical parameters of the cellular biochemical routes (AOP, adverse toxic outcome pathway-principle) in the target tissues. In vitro-tests are rapid and effective, and with them automation can be applied. The change in the testing paradigm is supported by all stakeholders: scientists, regulators and people concerned on animal welfare.

  10. Generic test platform for representative tests of safety I/C systems - 15546

    International Nuclear Information System (INIS)

    Fourestie, B.; Kuck, H.; Richter, J.; Rieche, S.; Waitz, M.

    2015-01-01

    In compliance with the IEC 61513 safety Instrumentation and Control (I/C) systems must be successfully validated in their final configuration prior to installation on site and commissioning. However the contingent need for modifications during system validation activities or subsequently during the commissioning phase may entail long and costly re-engineering of the I/C systems. With the view to ease these possible modifications, a Generic Test Platform has been developed by AREVA which allows combining a real I/C system subpart with an emulation server. This platform provides a faithful representation of the I/C System allowing crediting the validation test results carried out on this platform. (authors)

  11. Inquiry relating to safety due to modification of usage of nuclear fuel material (establishment of waste safety testing facility) in Tokai Laboratory, Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    1979-01-01

    Application was made to the director of the Science and Technology Agency (STA) for the license relating to the modification of usage of nuclear fuel material (the establishment of waste safety testing facility) from the director of the Japan Atomic Energy Research Institute on November 30, 1978. After passing through the safety evaluation in the Nuclear Safety Bureau of STA, inquiry was conducted to the head of the Atomic Energy Safety Commission (AESC) on June 6, 1979, from the director of the STA. The head of AESC directed to conduct the safety examination to the head of the Nuclear Fuel Safety Examination Specialist Committee on June 7, 1979. The content of the modification of usage of nuclear fuel material is the establishment of waste safety testing facility to study and test the safety relating to the treatment and disposal of high level radioactive liquid wastes due to the reprocessing of spent fuel. As for the results of the safety examination, the siting of the waste safety testing facility which is located in the Tokai Laboratory, Japan Atomic Energy Research Institute (JAERI), and the test plan of the glass solidification of high level radioactive liquid are presented as the outline of the study plan. The building, main equipments including six cells, the isolation room and the glove box, the storage, and the disposal facilities for gas, liquid and solid wastes are explained as the outline of the facilities. Concerning the items from the viewpoint of safety, aseismatic design, slightly vacuum operation, shielding, decay heat removal, fire protection, explosion protection, criticality management, radiation management and environmental effect were evaluated, and the safety was confirmed. (Nakai, Y.)

  12. Evaluation of Four Bedside Test Systems for Card Performance, Handling and Safety.

    Science.gov (United States)

    Giebel, Felix; Picker, Susanne M; Gathof, Birgit S

    2008-01-01

    SUMMARY: OBJECTIVE: Pretransfusion ABO compatibility testing is a simple and required precaution against ABO-incompatible transfusion, which is one of the greatest threats in transfusion medicine. While distinct agglutination is most important for correct test interpretation, protection against infectious diseases and ease of handling are crucial for accurate test performance. Therefore, the aim of this study was to evaluate differences in test card design, handling, and user safety. DESIGN: Four different bedside test cards with pre-applied antibodies were evaluated by 100 medical students using packed red blood cells of different ABO blood groups. Criteria of evaluation were: agglutination, labelling, handling, and safety regarding possible user injuries. Criteria were rated subjectively according to German school notes ranging from 1 = very good to 6 = very bad/insufficient. RESULTS: Overall, all cards received very good/good marks. The ABO blood group was identified correctly in all cases. Three cards (no. 1, no. 3, no. 4) received statistically significant (p labelling (1.5 vs. 2.2-2.4), handling (1.9-2.0 vs. 2.5), and user safety (2.5 vs. 3.4). Analysis of card self-explanation revealed no remarkable differences. CONCLUSION: Despite good performance of all card systems tested, the best results when including all criteria evaluated were obtained with card no. 4 (particularly concerning clear agglutination), followed by cards no. 2, no. 1, and no. 3.

  13. Safety analysis calculations for research and test reactors

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S Y; MacDonald, R; MacFarlane, D [Argonne National Laboratory, Argonne, IL (United States)

    1983-08-01

    The goal of the RERTR (Reduced Enrichment in Research and Test Reactor) Program at ANL is to provide technical means for conversion of research and test reactors from HEU (High-Enrichment Uranium) to LEU (Low-Enrichment Uranium) fuels. In exploring the feasibility of conversion, safety considerations are a prime concern; therefore, safety analyses must be performed for reactors undergoing the conversion. This requires thorough knowledge of the important safety parameters for different types of reactors for both HEU and LEU fuel. Appropriate computer codes are needed to predict transient reactor behavior under postulated accident conditions. In this discussion, safety issues for the two general types of reactors i.e., the plate-type (MTR-type) reactor and the rod-type (TRIGA-type) reactor, resulting from the changes associated with LEU vs. HEU fuels, are explored. The plate-type fuels are typically uranium aluminide (UAl{sub x}) compounds dispersed in aluminum and clad with aluminum. Moderation is provided by the water coolant. Self shut-down reactivity coefficients with EU fuel are entirely a result of coolant heating, whereas with LEU fuel there is an additional shut down contribution provided by the direct heating of the fuel due to the Doppler coefficient. In contrast, the rod-type (TRIGA) fuels are mixtures of zirconium hydride, uranium, and erbium. This fuel mixture is formed into rods ( {approx} 1 cm diameter) and clad with stainless steel or Incoloy. In the TRIGA fuel the self-shutdown reactivity is more complex, depending on heating of the fuel rather than the coolant. The two most important mechanisms in providing this feedback are: spectral hardening due to neutron interaction with the ZrH moderator as it is heated and Doppler broadening of resonances in erbium and U-238. Since these phenomena result directly from heating of the fuel, and do not depend on heat transfer to the moderator/coolant, the coefficients are prompt acting. Results of transient

  14. Safety Analysis of the US Dual Coolant Liquid Lead-Lithium ITER Test Blanket Module

    Energy Technology Data Exchange (ETDEWEB)

    Merrill, Brad; Reyes, Susana; Sawan, Mohamed; Wong, Clement

    2006-07-01

    The US is proposing a prototype of a dual coolant liquid lead-lithium (DCLL) DEMO blanket concept for testing in the International Thermonuclear Experimental Reactor (ITER) as an ITER Test Blanket Module (TBM). Because safety considerations are an integral part of the design process to ensure that this TBM does not adversely impact the safety of ITER, a safety assessment has been conducted for this TBM and its ancillary systems as requested by the ITER project. Four events were selected by the ITER International Team (IT) to address specific reactor safety concerns, such as VV pressurization, confinement building pressure build-up, TBM decay heat removal capability, tritium and activation products release from the TBM system, and hydrogen and heat production from chemical reactions. This paper summarizes the results of this safety assessment conducted with the MELCOR computer code.

  15. A safety concern related to CANDU moderator subcooling and status of KAERI moderator circulation test (MCT) experiments

    International Nuclear Information System (INIS)

    Rhee, Bo W.; Kim, Hyoung T.; Kim, Tongbeum; Im, Sunghyuk

    2015-01-01

    The flow inside the moderator tank of a CANDU-6 reactor during full power steady state operation has been suspected to be operating in the buoyancy/inertial driven mixed convection regime as illustrated in the middle figure. At some regions of the moderator tank where the buoyancy driven upward flow and the inertial momentum driven downward flows interface counter-currently, there exist some interface regions between these two flows like the middle one, and the local temperatures at these interface regions are known to oscillate with different amplitude at various fluctuation frequencies as shown. According to a numerical simulation of the moderator flow and temperature distribution at full power steady state carried out by previous researches showed that any small disturbances in the flow or temperature may initiate the system unstable and aggravate the asymmetric flow and temperature patterns. The tests at the 3-D Moderator Test Facility (MTF) that is a representative scaled-down of CANDU reactors, reproduced the expected and observed moderator behavior in the reactor as well as the local temperature fluctuations arising from the delicate balance of forced and buoyancy induced flow. This observation raised a safety concern as the local moderator temperature at some regions showed fluctuations with an amplitude that may jeopardize the safety margin, i.e. the difference between the available subcooling and the subcooling requirement. The scope of this paper is to review the basis of the safety concern related to this moderator subcooling and local temperature fluctuation and describe the current status of MCT erection and some of the experiments carried so far

  16. Safety and Function Test Report for the SWIFT Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, I.; Hur, J.

    2013-01-01

    This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. Three turbines where selected for testing at the National Wind Technology Center (NWTC) as a part of round two of the Small Wind Turbine Independent Testing project. Safety and Function testing is one of up to 5 tests that may be performed on the turbines. Other tests include power performance, duration, noise, and power quality. The results of the testing will provide the manufacturers with reports that may be used for small wind turbine certification.

  17. New methods for the safety testing of transgenic food

    DEFF Research Database (Denmark)

    Knudsen, Ib; Poulsen, Morten; Kledal, S. T.

    2004-01-01

    for guiding the precise design of the animal study. The genetically modified food plants to be used for this test development will be 3 transgenic rice varieties (2 types of lectins and the Bt toxin). Objectives The overall objective of this project is to develop and validate the scientific methodology which......Background This project proposal deals with the development of a sensitive and specific animal test which is necessary for safety analysis of genetically modified plants according to the Opinion of the Scientific Committee for Food on the assessment of novels foods. The test will be based...

  18. Safety of a rapid diagnostic protocol with accelerated stress testing.

    Science.gov (United States)

    Soremekun, Olan A; Hamedani, Azita; Shofer, Frances S; O'Conor, Katie J; Svenson, James; Hollander, Judd E

    2014-02-01

    Most patients at low to intermediate risk for an acute coronary syndrome (ACS) receive a 12- to 24-hour "rule out." Recently, trials have found that a coronary computed tomographic angiography-based strategy is more efficient. If stress testing were performed within the same time frame as coronary computed tomographic angiography, the 2 strategies would be more similar. We tested the hypothesis that stress testing can safely be performed within several hours of presentation. We performed a retrospective cohort study of patients presenting to a university hospital from January 1, 2009, to December 31, 2011, with potential ACS. Patients placed in a clinical pathway that performed stress testing after 2 negative troponin values 2 hours apart were included. We excluded patients with ST-elevation myocardial infarction or with an elevated initial troponin. The main outcome was safety of immediate stress testing defined as the absence of death or acute myocardial infarction (defined as elevated troponin within 24 hours after the test). A total of 856 patients who presented with potential ACS were enrolled in the clinical pathway and included in this study. Patients had a median age of 55.0 (interquartile range, 48-62) years. Chest pain was the chief concern in 86%, and pain was present on arrival in 73% of the patients. There were no complications observed during the stress test. There were 0 deaths (95% confidence interval, 0%-0.46%) and 4 acute myocardial infarctions within 24 hours (0.5%; 95% confidence interval, 0.14%-1.27%). The peak troponins were small (0.06, 0.07, 0.07, and 0.19 ng/mL). Patients who present to the ED with potential ACS can safely undergo a rapid diagnostic protocol with stress testing. © 2013.

  19. Making work safer: testing a model of social exchange and safety management.

    Science.gov (United States)

    DeJoy, David M; Della, Lindsay J; Vandenberg, Robert J; Wilson, Mark G

    2010-04-01

    This study tests a conceptual model that focuses on social exchange in the context of safety management. The model hypothesizes that supportive safety policies and programs should impact both safety climate and organizational commitment. Further, perceived organizational support is predicted to partially mediate both of these relationships. Study outcomes included traditional outcomes for both organizational commitment (e.g., withdrawal behaviors) as well as safety climate (e.g., self-reported work accidents). Questionnaire responses were obtained from 1,723 employees of a large national retailer. Using structural equation modeling (SEM) techniques, all of the model's hypothesized relationships were statistically significant and in the expected directions. The results are discussed in terms of social exchange in organizations and research on safety climate. Maximizing safety is a social-technical enterprise. Expectations related to social exchange and reciprocity figure prominently in creating a positive climate for safety within the organization. Copyright 2010 Elsevier Ltd. All rights reserved.

  20. PIE on Safety-Tested AGR-1 Compact 5-1-1

    Energy Technology Data Exchange (ETDEWEB)

    Hunn, John D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Morris, Robert Noel [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baldwin, Charles A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Montgomery, Fred C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gerczak, Tyler J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-08-01

    Post-irradiation examination (PIE) is being performed in support of tristructural isotropic (TRISO) coated particle fuel development and qualification for High-Temperature Gas-cooled Reactors (HTGRs). AGR-1 was the first in a series of TRISO fuel irradiation experiments initiated in 2006 under the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program; this work continues to be funded by the Department of Energy's Office of Nuclear Energy as part of the Advanced Reactor Technologies (ART) initiative. AGR-1 fuel compacts were fabricated at Oak Ridge National Laboratory (ORNL) in 2006 and irradiated for three years in the Idaho National Laboratory (INL) Advanced Test Reactor (ATR) to demonstrate and evaluate fuel performance under HTGR irradiation conditions. PIE is being performed at INL and ORNL to study how the fuel behaved during irradiation, and to examine fuel performance during exposure to elevated temperatures at or above temperatures that could occur during a depressurized conduction cooldown event. This report summarizes safety testing of irradiated AGR-1 Compact 5-1-1 in the ORNL Core Conduction Cooldown Test Facility (CCCTF) and post-safety testing PIE.

  1. Test Bed for Safety Assessment of New e-Navigation Systems

    Directory of Open Access Journals (Sweden)

    Axel Hahn

    2014-12-01

    Full Text Available New e-navigation strains require new technologies, new infrastructures and new organizational structures on bridge, on shore as well as in the cloud. Suitable engineering and safety/risk assessment methods facilitate these efforts. Understanding maritime transportation as a sociotechnical system allows the application of system-engineering methods. Formal, simulation based and in situ verification and validation of e-navigation technologies are important methods to obtain system safety and reliability. The modelling and simulation toolset HAGGIS provides methods for system specification and formal risk analysis. It provides a modelling framework for processes, fault trees and generic hazard specification and a physical world and maritime traffic simulation system. HAGGIS is accompanied by the physical test bed LABSKAUS which implements a physical test bed. The test bed provides reference ports and waterways in combination with an experimental Vessel Traffic Services (VTS system and a mobile integrated bridge: This enables in situ experiments for technological evaluation, testing, ground research and demonstration. This paper describes an integrated seamless approach for developing new e-navigation technologies starting with simulation based assessment and ending in physical real world demonstrations

  2. Evaluation of seven in vitro alternatives for ocular safety testing.

    Science.gov (United States)

    Bruner, L H; Kain, D J; Roberts, D A; Parker, R D

    1991-07-01

    Seven in vitro assays were evaluated to determine if any were useful as screening procedures in ocular safety assessment. Seventeen test materials (chemicals, household cleaners, hand soaps, dishwashing liquids, shampoos, and liquid laundry detergents) were tested in each assay. In vivo ocular irritation scores for the materials were obtained from existing rabbit low volume eye test (LVET) data. The seven assays evaluated included the silicon microphysiometer (SM), luminescent bacteria toxicity test (LBT), neutral red assay (NR), total protein assay (TP), Tetrahymena thermophila motility assay (TTMA), bovine eye/chorioallantoic membrane assay (BE/CAM), and the EYTEX system (ETS). For the seventeen materials used in this study there was a significant correlation between the in vivo irritant potential and in vitro data for all the tests except the EYTEX System (SM, r = -0.87; LBT, r = -0.91; NR, r = -0.85; TTMA, r = 0.78; TP, r = -0.86; ETS, r = 0.29). The irritation classifications provided by the BE/CAM also did not correspond with the actual in vivo irritancy potential of the test materials. The result of this study suggested it may be possible to classify materials into broad irritancy categories with some of the assays. This would allow their use as screens prior to limited in vivo confirmation in the ocular safety assessment process.

  3. Topical session proceedings of the 5. IGSC meeting on: observations regarding the safety case in recent safety assessment studies

    International Nuclear Information System (INIS)

    Hooper, Alan J.; Voinis, Sylvie; Van Luik, Abraham E.

    2004-01-01

    Within the NEA, the IGSC (Integration Group for the Safety Case) has, as an essential role, to develop common views on such key aspects of the safety case. Therefore, since the inauguration of the IGSC in 2000, four meetings were organised with topical sessions to explore various of these key aspects. This is a report on the fifth such topical session, held as part of the 5. plenary meeting of the IGSC. The session was attended by 36 participants, representing waste management organisations and regulatory authorities from 16 NEA member countries, the IAEA and the European Commission. The purpose of this topical session was to provide support to the finalising of the IGSC safety case brochure by getting a description of the safety case content of the IAEA Draft Safety Requirements document and by getting an overview of progress that could be observed from national organisations on developing their cases for system safety and/or developing the required methodologies. The objective was that the IGSC safety case brochure should be supportive of the IAEA/NEA document, and be reflective of the experience of the IGSC member programmes and organisations. The topical session was mainly aimed at exchanging information on: - The safety case related content of the proposed IAEA/NEA document (currently titled: 'IAEA Safety Standards Series, Geological Disposal of Radioactive Waste, Draft Safety Requirements (DS-154)'). - National programmes where safety assessments have recently been completed, e.g. ONDRAF/NIRAS, Nagra and Andra. - Feedback from international peer reviews, e.g. the Andra Dossier 2001 Argile, the Belgian SAFIR 2 report, the SR 97 report and the US-DOE Yucca Mountain TSPA. - The evolution of some national assessment methods and approaches e.g. SKB and Nagra. - The content of the draft IGSC safety case brochure entitled: 'The Nature and Purpose of the Post-closure Safety Case in Geological Disposal'. This document presents the various

  4. HIGH-TEMPERATURE SAFETY TESTING OF IRRADIATED AGR-1 TRISO FUEL

    Energy Technology Data Exchange (ETDEWEB)

    Stempien, John D.; Demkowicz, Paul A.; Reber, Edward L.; Chrisensen, Cad L.

    2016-11-01

    High-Temperature Safety Testing of Irradiated AGR-1 TRISO Fuel John D. Stempien, Paul A. Demkowicz, Edward L. Reber, and Cad L. Christensen Idaho National Laboratory, P.O. Box 1625 Idaho Falls, ID 83415, USA Corresponding Author: john.stempien@inl.gov, +1-208-526-8410 Two new safety tests of irradiated tristructural isotropic (TRISO) coated particle fuel have been completed in the Fuel Accident Condition Simulator (FACS) furnace at the Idaho National Laboratory (INL). In the first test, three fuel compacts from the first Advanced Gas Reactor irradiation experiment (AGR-1) were simultaneously heated in the FACS furnace. Prior to safety testing, each compact was irradiated in the Advanced Test Reactor to a burnup of approximately 15 % fissions per initial metal atom (FIMA), a fast fluence of 3×1025 n/m2 (E > 0.18 MeV), and a time-average volume-average (TAVA) irradiation temperature of about 1020 °C. In order to simulate a core-conduction cool-down event, a temperature-versus-time profile having a peak temperature of 1700 °C was programmed into the FACS furnace controllers. Gaseous fission products (i.e., Kr-85) were carried to the Fission Gas Monitoring System (FGMS) by a helium sweep gas and captured in cold traps featuring online gamma counting. By the end of the test, a total of 3.9% of an average particle’s inventory of Kr-85 was detected in the FGMS traps. Such a low Kr-85 activity indicates that no TRISO failures (failure of all three TRISO layers) occurred during the test. If released from the compacts, condensable fission products (e.g., Ag-110m, Cs-134, Cs-137, Eu-154, Eu-155, and Sr-90) were collected on condensation plates fitted to the end of the cold finger in the FACS furnace. These condensation plates were then analyzed for fission products. In the second test, five loose UCO fuel kernels, obtained from deconsolidated particles from an irradiated AGR-1 compact, were heated in the FACS furnace to a peak temperature of 1600 °C. This test had two

  5. Minnesota urban partnership agreement national evaluation : safety data test plan.

    Science.gov (United States)

    2009-11-17

    This report provides the safety data test plan for the Minnesota Urban Partnership Agreement (UPA) under the United States Department of Transportation (U.S. DOT) UPA Program. The Minnesota UPA projects focus on reducing congestion by employing strat...

  6. Test and assessment method of Automotive Safety Systems (SSB) particularly to monitor traffic incidents

    Science.gov (United States)

    Pijanowski, B.; Łukjanow, S.; Burliński, R.

    2016-09-01

    The rapid development of telematics, particularly mobile telephony (GSM), wireless data transmission (GPRS) and satellite positioning (GPS) noticeable in the last decade, resulted in an almost unlimited growth of the possibilities for monitoring of mobile objects. These solutions are already widely used in the so-called “Intelligent Transport Systems” - ITS and affect a significant increase for road safety. The article describes a method of testing and evaluation of Car Safety Systems (Polish abbreviation - SSB) especially for monitoring traffic incidents, such as collisions and accidents. The algorithm of SSB testing process is also presented. Tests are performed on the dynamic test bench, part of which is movable platform with car security system mounted on it. Crash tests with a rigid obstacle are carried out instead of destructive attempts to crash test of the entire vehicle which is expensive. The tested system, depending on the simulated traffic conditions, is mounted in such a position and with the use of components, indicated by the manufacturer for the automotive safety system installation in a vehicle, for which it is intended. Then, the tests and assessments are carried out.

  7. Test tools of physics radiography children as a support for safety radiation and safety patients

    International Nuclear Information System (INIS)

    Siti Masrochah; Yeti Kartikasari; Ardi Soesilo Wibowo

    2013-01-01

    Radiographic examination of the thorax children aged 1-3 years have a high sufficiently failure. This failure is caused by the movement and difficulty positioning the patient, resulting in the risk of repeat radiographs to patient safety particularly unnecessary radiation risks. It is therefore necessary to develop research on children design fixation devices. This research aims to create a design tool fixation on radiographs children to support radiation safety and patient safety. This research is a descriptive exploratory approach to tool design. The independent variables were the design tools, variable tool function test results, and radiographic variables controlled thorax. The procedure is done by designing data collection tools, further trials with 20 samples. Processing and analysis of data is done by calculating the performance assessment tool scores with range 1-3. The results showed that the design tool of fixation in the form of standard radiographic cassette equipped with chairs and some form of seat belt fixation. The procedure uses a tool fixation is routine radiographic follow thorax child in an upright position. Function test results aids fixation is to have an average score of 2.66, which means good. While the test results for each component, the majority of respondents stated that the reliability of the device is quite good with a score of 2.45 (60 %), convenience tool with a score of 2.60 (70 %), quality of the radiographs did not incontinence of the thorax radiograph with a score 2.55 (85 %), the child protection (security) with a score of 2.70 (70 %), good design aesthetic design with a score of 2.80 (80 %), addition of radiation from the others on the use of these tools do not need with a score of 2.80 (80 %), and there is no additional radiation due to repetitions with a score of 2.85 (90 %). (author)

  8. Occupational safety and health textbook for radiological personnel employed in structural material testing

    International Nuclear Information System (INIS)

    Abraham, J.

    1981-01-01

    The comprehensive textbook for X-ray and radiological testing personnel includes requirements and rules of occupational safety and health on the basis of Hungarian and international (mainly German) literature. In the chapter Fundamentals, X-ray and radioactive radiations, their measurements and biological effects, doses etc are described. In the chapter Occupational safety and health, the jobs representing radiation hazards are listed and safety regulations for them are reported. Finally, information for prevention and first aid is presented. Control questions are added to each part. The Appendix contains safety standards and regulations, information on legal aspects of safety and radiation protection as well as recommendations. (Sz.J.)

  9. Operational safety assessment of underground test facilities for mined geologic waste disposal

    International Nuclear Information System (INIS)

    Elder, H.K.

    1993-01-01

    This paper describes the operational safety assessment for the underground facilities for the exploratory studies facility (ESF) at the Yucca Mountain Project. The systematic identification and evaluation of hazards related to the ESF is an integral part of the systems engineering process; whereby safety is considered during planning, design, testing, and construction. A largely qualitative approach based on the analysis of potential accidents was used since radiological safety analysis was not required. The risk assessment summarized credible accident scenarios and the design provides mitigation of the risks to a level that the facility can be constructed and operated with an adequate level of safety. The risk assessment also provides reasonable assurance that all identifiable major accident scenarios have been reviewed and design mitigation features provided to ensure an adequate level of safety

  10. Advanced Test Reactor (ATR) Facility 10CFR830 Safety Basis Related to Facility Experiments

    International Nuclear Information System (INIS)

    Tomberlin, T.A.

    2002-01-01

    The Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Test Reactor (ATR), a DOE Category A reactor, was designed to provide an irradiation test environment for conducting a variety of experiments. The ATR Safety Analysis Report, determined by DOE to meet the requirements of 10 CFR 830, Subpart B, provides versatility in types of experiments that may be conducted. This paper addresses two general types of experiments in the ATR facility and how safety analyses for experiments are related to the ATR safety basis. One type of experiment is more routine and generally represents greater risks; therefore this type of experiment is addressed with more detail in the safety basis. This allows individual safety analyses for these experiments to be more routine and repetitive. The second type of experiment is less defined and is permitted under more general controls. Therefore, individual safety analyses for the second type of experiment tend to be more unique from experiment to experiment. Experiments are also discussed relative to ''major modifications'' and DOE-STD-1027-92. Application of the USQ process to ATR experiments is also discussed

  11. Major results from safety-related integral effect tests with VISTA-ITL for the SMART design

    International Nuclear Information System (INIS)

    Park, H. S.; Min, B. Y.; Shin, Y. C.; Yi, S. J.

    2012-01-01

    A series of integral effect tests (IETs) was performed by the Korea Atomic Energy Research Inst. (KAERI) using the VISTA integral test loop (VISTA-ITL) as a small-scale IET program. Among them this paper presents major results acquired from the safety-related IETs with the VISTA-ITL facility for the SMART design. Three small-break loss-of-coolant accident (SBLOCA) tests of safety injection system (SIS) line break, shutdown cooling system (SCS) line break and pressurizer safety valve (PSV) line break were successfully performed and the transient characteristics of a complete loss of flowrate (CLOF) was simulated properly with the VISTA-ITL facility. (authors)

  12. A Method to Select Test Input Cases for Safety-critical Software

    International Nuclear Information System (INIS)

    Kim, Heeeun; Kang, Hyungook; Son, Hanseong

    2013-01-01

    This paper proposes a new testing methodology for effective and realistic quantification of RPS software failure probability. Software failure probability quantification is important factor in digital system safety assessment. In this study, the method for software test case generation is briefly described. The test cases generated by this method reflect the characteristics of safety-critical software and past inputs. Furthermore, the number of test cases can be reduced, but it is possible to perform exhaustive test. Aspect of software also can be reflected as failure data, so the final failure data can include the failure of software itself and external influences. Software reliability is generally accepted as the key factor in software quality since it quantifies software failures which can make a powerful system inoperative. In the KNITS (Korea Nuclear Instrumentation and Control Systems) project, the software for the fully digitalized reactor protection system (RPS) was developed under a strict procedure including unit testing and coverage measurement. Black box testing is one type of Verification and validation (V and V), in which given input values are entered and the resulting output values are compared against the expected output values. Programmable logic controllers (PLCs) were used in implementing critical systems and function block diagram (FBD) is a commonly used implementation language for PLC

  13. French safety and criticality testing programmes

    International Nuclear Information System (INIS)

    Barbry, F.; Leclerc, J.; Manaranche, J.C.; Maubert, L.

    1982-01-01

    This article underlines the need to include experimental safety-criticality programmes in the French nuclear effort. The means and methods used at the Section of Experimental Nuclear Safety and Criticality Research, attached to the CEA Valduc Centre, are described. Three experimental programmes are presented: safety-criticality of the PWR fuel cycle, neutron poisoning of plutonium solutions by gadolinium and safety-criticality of slightly enriched and slightly moderated uranium oxide. Criticality accidents studies in solution are then described [fr

  14. Safety re-assessment of AECL test and research reactors

    International Nuclear Information System (INIS)

    Winfield, D.J.

    1990-01-01

    Atomic Energy of Canada Limited currently has four operating engineering test/research reactors of various sizes and ages; a new isotope-production reactor Maple-X10, under construction at Chalk River Nuclear Laboratories (CRNL), and a heating demonstration reactor, SDR, undergoing high-power commissioning at Whiteshell Nuclear Research Establishment (WNRE). The company is also performing design studies of small reactors for hot water and electricity production. The older reactors are ZED-2, PTR, NRX, and NRU; these range in age from 42 years (NRX) to 29 years (ZED-2). Since 1984, limited-scope safety re-assessments have been underway on three of these reactors (ZED-2, NRX AND NRU). ZED-2 and PTR are operated by the Reactor Physics Branch; all other reactors are operated by the respective site Reactor Operations Branches. For the older reactors the original safety reports produced were entirely deterministic in nature and based on the design-basis accident concept. The limited scope safety re-assessments for these older reactors, carried out over the past 5 years, have comprised both quantitative probabilistic safety-assessment techniques, such as event tree and fault analysis, and/or qualitative techniques, such as failure mode and effect analysis. The technique used for an individual assessment was dependent upon the specific scope required. This paper discusses the types of analyses carried out, specific insights/recommendations resulting from the analysis, and the plan for future analysis. In addition, during the last four years safety assessments have been carried out on the new isotope-, heat-, and electricity-producing reactors, as part of the safety design review, commissioning and licensing activities

  15. Safety assessment for the 118-B-1 Burial Ground excavation treatability tests. Revision 2

    International Nuclear Information System (INIS)

    Zimmer, J.J.; Frain, J.M.

    1994-12-01

    This revision of the Safety Assessment provides an auditable safety analysis of the hazards for the proposed treatability test activities per DOE-EM-STD-5502-94, DOE Limited Standard, Hazard Baseline Documentation (DOE 1994). The proposed activities are classified as radiological activities and as such, no longer require Operational Safety Limits (OSLs). The OSLS, Prudent Actions, and Institutional and Organization Controls have been removed from this revision and replaced with ''Administrative Actions Important to Safety,'' as determined by the hazards analysis. Those Administrative Actions Important to Safety are summarized in Section 1.1, ''Assessment Summary.''

  16. Observational tests of modified gravity

    International Nuclear Information System (INIS)

    Jain, Bhuvnesh; Zhang Pengjie

    2008-01-01

    Modifications of general relativity provide an alternative explanation to dark energy for the observed acceleration of the Universe. Modified gravity theories have richer observational consequences for large-scale structures than conventional dark energy models, in that different observables are not described by a single growth factor even in the linear regime. We examine the relationships between perturbations in the metric potentials, density and velocity fields, and discuss strategies for measuring them using gravitational lensing, galaxy cluster abundances, galaxy clustering/dynamics, and the integrated Sachs-Wolfe effect. We show how a broad class of gravity theories can be tested by combining these probes. A robust way to interpret observations is by constraining two key functions: the ratio of the two metric potentials, and the ratio of the gravitational 'constant' in the Poisson equation to Newton's constant. We also discuss quasilinear effects that carry signatures of gravity, such as through induced three-point correlations. Clustering of dark energy can mimic features of modified gravity theories and thus confuse the search for distinct signatures of such theories. It can produce pressure perturbations and anisotropic stresses, which break the equality between the two metric potentials even in general relativity. With these two extra degrees of freedom, can a clustered dark energy model mimic modified gravity models in all observational tests? We show with specific examples that observational constraints on both the metric potentials and density perturbations can in principle distinguish modifications of gravity from dark energy models. We compare our result with other recent studies that have slightly different assumptions (and apparently contradictory conclusions).

  17. Modification of a compressor performance test bench for liquid slugging observation in refrigeration compressors

    Science.gov (United States)

    Ola, Max; Thomas, Christiane; Hesse, Ullrich

    2017-08-01

    Compressor performance test procedures are defined by the standard DIN EN 13771, wherein a variety of possible calorimeter and flow rate measurement methods are suggested. One option is the selection of two independent measurement methods. The accuracies of both selected measurement methods are essential. The second option requires only one method. However the measurement accuracy of the used device has to be verified and recalibrated on a regular basis. The compressor performance test facility at the Technische Universitaet Dresden uses a calibrated flow measurement sensor, a hot gas bypass and a mixed flow heat exchanger. The test bench can easily be modified for tests of various compressor types at different operating ranges and with various refrigerants. In addition, the modified test setup enables the investigation of long term liquid slug and its effects on the compressor. The modification comprises observational components, adjustments of the control system, safety measures and a customized oil recirculation system for compressors which do not contain an integrated oil sump or oil level regulation system. This paper describes the setup of the test bench, its functional principle, the key modifications, first test results and an evaluation of the energy balance.

  18. Major Results from 1-Train Passive Safety System Tests for the SMART Design with the SMART-ITL Facility

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun-Sik; Bae, Hwang; Ryu, Sung-Uk; Jeon, Byong-Guk; Ruy, Hyobong; Kim, Woo-Shik; Byun, Sun-Joon; Shin, Yong-Cheol; Min, Kyoung-Ho; Yi, Sung-Jae [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    To satisfy the domestic and international needs for nuclear safety improvement after the Fukushima accident, an effort to improve its safety has been studied, and a Passive Safety System (PSS) for SMART has been designed. In addition, an Integral Test Loop for the SMART design (SMART-ITL, or FESTA) has been constructed and it finished its commissioning tests in 2012. Consequently, a set of Design Base Accident (DBA) scenarios have been simulated using SMARTITL. Recently, a test program to validate the performance of the SMART PSS was launched and its scaled-down test facility was additionally installed at the existing SMART-ITL facility. In this paper, the major results from the 1-train passive safety system validation tests with the SMARTITL facility will be summarized. The acquired data will be used to validate the safety analysis code and its related models, to evaluate the performance of SMART PSS, and to provide base data during the application phase of the SDA revision and construction licensing. In this paper, the major results from the validation tests of the SMART passive safety system using a 1-train test facility were summarized. They include a dozen of SMART PSS tests using 1-train SMART PSS tests. From the test results, it was estimated that the SMART PSS has sufficient cooling capability to deal with the SBLOCA scenario of SMART. During the SBLOCA scenario, in the CMT, the water layer inventory was well stratified thermally and the safety injection water was injected efficiently into the RPV from the initial period, and cools down the RCS properly.

  19. A probabilistic safety assessment of in-pile test loop in HWRR

    International Nuclear Information System (INIS)

    Cao Xuewu; Li Zhaohuan

    1991-07-01

    The PSA methodology has been applied to the in-pile test loop which is installed in the Heavy Water Research Reactor (HWRR). This loop is designed and operated for fuel assembly testing of the Qinshan PWR plant. This analysis is to assess the safety and to evaluate the design of this operating loop. The procedure and models are similar to a PSA on nuclear power plant. The major contents in the analysis consist of the familiarization of the object, the investigation and selection of accident initiators, setting events and fault trees, data collections, quantitative calculations, qualitative and result analyses and final conclusion. This analysis is only limited to the initiators of in-pile loop itself and possible errors made by operators during normal operation. The accident occurence is less than 10 -4 a -1 which may be recommended as an acceptance risk for safety operation of an in-pile test loop. Finally, suggestions have been raised to improve the design of test loop, especially in reducing operation errors by local operators

  20. Technology Solutions Case Study: Combustion Safety Simplified Test Protocol

    Energy Technology Data Exchange (ETDEWEB)

    L. Brand, D. Cautley, D. Bohac, P. Francisco, L. Shen, and S. Gloss

    2015-12-01

    Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives.

  1. Thermohydraulic tests in the area of reactor safety done in CDTN

    International Nuclear Information System (INIS)

    Ladeira, L.C.D.

    1990-01-01

    The main experimental works performed in the last five years at the Thermohydraulics Laboratory of the Nuclear Technology Development Center, in the field of reactor safety are briefly described. This paper cover the performing and analysis of pressure drop, heat transfer and mixing tests in 3X3 rod bundle and rewetting tests in single tube section. (autor) [pt

  2. Integrated, digital experiment transient control and safety protection of an in-pile test

    International Nuclear Information System (INIS)

    Thomas, R.W.; Whitacre, R.F.; Klingler, W.B.

    1982-01-01

    The Sodium Loop Safety Facility experimental program has demonstrated that in-pile loop fuel failure transient tests can be digitally controlled and protected with reliability and precision. This was done in four nuclear experiments conducted in the Engineering Test Reactor operated by EG and G Idaho, Inc., at the Idaho National Engineering Laboratory. Loop sodium flow and reactor power transients can be programmed to sponsor requirements and verified prior to the test. Each controller has redundancy, which reduces the effect of single failures occurring during test transients. Feedback and reject criteria are included in the reactor power control. Timed sequencing integrates the initiation of the controllers, programmed safety set-points, and other experiment actions (e.g., planned scram). Off-line and on-line testing is included. Loss-of-flow, loss-of-piping-integrity, boiling-window, transient-overpower, and local fault tests have been successfully run using this system

  3. Dimensions of Safety Climate among Iranian Nurses.

    Science.gov (United States)

    Konjin, Z Naghavi; Shokoohi, Y; Zarei, F; Rahimzadeh, M; Sarsangi, V

    2015-10-01

    Workplace safety has been a concern of workers and managers for decades. Measuring safety climate is crucial in improving safety performance. It is also a method of benchmarking safety perception. To develop and validate a psychometrics scale for measuring nurses' safety climate. Literature review, subject matter experts and nurse's judgment were used in items developing. Content validity and reliability for new tool were tested by content validity index (CVI) and test-retest analysis, respectively. Exploratory factor analysis (EFA) with varimax rotation was used to improve the interpretation of latent factors. A 40-item scale in 6 factors was developed, which could explain 55% of the observed variance. The 6 factors included employees' involvement in safety and management support, compliance with safety rules, safety training and accessibility to personal protective equipment, hindrance to safe work, safety communication and job pressure, and individual risk perception. The proposed scale can be used in identifying the needed areas to implement interventions in safety climate of nurses.

  4. French safety authority projects in the field of research and test reactors

    International Nuclear Information System (INIS)

    Saint Raymond, P.; Duthe, M.; Abou Yehia, H.

    2001-01-01

    This paper gives an outline of some actions initiated by the French safety authority in the field of research and test reactors. An important action concerns the definition of the authorisation criteria for the implementation of experiments in these reactors. In particular, it is necessary to define clearly in which conditions an experiment may be authorised internally by the operating organisation or needs a formal approval by the safety authority. The practice related to the systematic safety reassessment of old facilities and the regulatory provisions associated with the decommissioning are presented after a discussion on the ageing issues. (author)

  5. Predictors of driving safety in early Alzheimer disease.

    Science.gov (United States)

    Dawson, J D; Anderson, S W; Uc, E Y; Dastrup, E; Rizzo, M

    2009-02-10

    To measure the association of cognition, visual perception, and motor function with driving safety in Alzheimer disease (AD). Forty drivers with probable early AD (mean Mini-Mental State Examination score 26.5) and 115 elderly drivers without neurologic disease underwent a battery of cognitive, visual, and motor tests, and drove a standardized 35-mile route in urban and rural settings in an instrumented vehicle. A composite cognitive score (COGSTAT) was calculated for each subject based on eight neuropsychological tests. Driving safety errors were noted and classified by a driving expert based on video review. Drivers with AD committed an average of 42.0 safety errors/drive (SD = 12.8), compared to an average of 33.2 (SD = 12.2) for drivers without AD (p < 0.0001); the most common errors were lane violations. Increased age was predictive of errors, with a mean of 2.3 more errors per drive observed for each 5-year age increment. After adjustment for age and gender, COGSTAT was a significant predictor of safety errors in subjects with AD, with a 4.1 increase in safety errors observed for a 1 SD decrease in cognitive function. Significant increases in safety errors were also found in subjects with AD with poorer scores on Benton Visual Retention Test, Complex Figure Test-Copy, Trail Making Subtest-A, and the Functional Reach Test. Drivers with Alzheimer disease (AD) exhibit a range of performance on tests of cognition, vision, and motor skills. Since these tests provide additional predictive value of driving performance beyond diagnosis alone, clinicians may use these tests to help predict whether a patient with AD can safely operate a motor vehicle.

  6. Wind Turbine Generator System Safety and Function Test Report for the Southwest Windpower H40 Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    van Dam, J.; Link, H.; Meadors, M.; Bianchi, J.

    2002-06-01

    The objective of this test was to evaluate the safety and function characteristics of the Whisper H40 wind turbine. The general requirements of wind turbine safety and function tests are defined in the IEC standard WT01. The testing was conducted in accordance with the National Wind Technology Center (NWTC) Quality Assurance System, including the NWTC Certification Team Certification Quality Manual and the NWTC Certification Team General Quality Manual for the Testing of Wind Turbines, as well as subordinate documents. This safety and function test was performed as part of the U.S. Department of Energy's Field Verification Program for small wind turbines.

  7. Testing Challenges of Maritime Safety and Security Systems-of-Systems

    NARCIS (Netherlands)

    Gonzalez, A.; Piel, E.; Gross, H.G.

    2008-01-01

    Preprint of paper published in: TAIC PART 2008: Testing: Academic & Industrial Conference, Practice and Research Techniques, 29-31 August 2008; doi:10.1109/TAIC-PART.2008.14 Maritime Safety and Security systems represent a novel kind of large-scale distributed component-based systems in which the

  8. Safety analyses for an in-pile SCWR fuel qualification test loop

    Energy Technology Data Exchange (ETDEWEB)

    Schulenberg, T.; Raque, M. [Karlsruhe Inst. of Tech., Karlsruhe (Germany)

    2014-07-01

    As a nuclear facility cooled with supercritical water has never been built nor operated in the past, the planned SCWR fuel qualification test will give the first experience with supercritical water-cooled nuclear systems in general. With a fuel inventory of almost 1 kg of UO{sub 2} with almost 20% enrichment, the supercritical pressure test section inside a low pressure, pool type research reactor needs to be cooled properly even in case of a number of postulated design basis accidents. Depressurization systems and emergency cooling systems will need to be designed with similar reliability as for a prototype reactor to ensure the integrity of barriers retaining the radioactive material. The paper reports about the safety concept and summarizes the safety analyses which have been performed in this context. (author)

  9. Maintenance of safety behaviors via response-produced stimuli.

    Science.gov (United States)

    Angelakis, Ioannis; Austin, Jennifer L

    2015-11-01

    Animal studies suggest that safety behaviors may be maintained by internally or externally produced safety signals, which function as positive reinforcers. We designed two experiments to test this phenomenon with humans. Participants played a computerized game in which they could earn or lose treasures by clicking on a map. In baseline, losses could be postponed by pressing a pedal that also produced a blue bar at the bottom of the screen. During test conditions, no losses were programmed, and pedal presses turned the bar from yellow to blue (Test 1) or blue to yellow (Test 2). In Experiment 2, new participants were exposed to the same conditions but were given information about the safety of the test environment. In both experiments, participants engaged in high rates of pedal pressing when presses were followed by blue bars, suggesting the bar functioned as a safety signal. We discuss how these findings may relate to safety behaviors commonly observed in certain mental health disorders. © The Author(s) 2015.

  10. Assuring consumer safety without animal testing: a feasibility case study for skin sensitisation.

    Science.gov (United States)

    Maxwell, Gavin; Aleksic, Maja; Aptula, Aynur; Carmichael, Paul; Fentem, Julia; Gilmour, Nicola; Mackay, Cameron; Pease, Camilla; Pendlington, Ruth; Reynolds, Fiona; Scott, Daniel; Warner, Guy; Westmoreland, Carl

    2008-11-01

    Allergic Contact Dermatitis (ACD; chemical-induced skin sensitisation) represents a key consumer safety endpoint for the cosmetics industry. At present, animal tests (predominantly the mouse Local Lymph Node Assay) are used to generate skin sensitisation hazard data for use in consumer safety risk assessments. An animal testing ban on chemicals to be used in cosmetics will come into effect in the European Union (EU) from March 2009. This animal testing ban is also linked to an EU marketing ban on products containing any ingredients that have been subsequently tested in animals, from March 2009 or March 2013, depending on the toxicological endpoint of concern. Consequently, the testing of cosmetic ingredients in animals for their potential to induce skin sensitisation will be subject to an EU marketing ban, from March 2013 onwards. Our conceptual framework and strategy to deliver a non-animal approach to consumer safety risk assessment can be summarised as an evaluation of new technologies (e.g. 'omics', informatics), leading to the development of new non-animal (in silico and in vitro) predictive models for the generation and interpretation of new forms of hazard characterisation data, followed by the development of new risk assessment approaches to integrate these new forms of data and information in the context of human exposure. Following the principles of the conceptual framework, we have been investigating existing and developing new technologies, models and approaches, in order to explore the feasibility of delivering consumer safety risk assessment decisions in the absence of new animal data. We present here our progress in implementing this conceptual framework, with the skin sensitisation endpoint used as a case study. 2008 FRAME.

  11. Testing of the Safety and the Effectiveness of Using Samjeong Pharmacopuncture Solution as Eye drops

    Directory of Open Access Journals (Sweden)

    Seo Hyung-Sik

    2012-03-01

    Full Text Available Objective: This experimental study was designed to investigate the safety and the effectiveness of Samjeong pharmacopuncture solution (SPS manufactured by using a the lowtemperature extract on process. Methods: To identify the safety and the effectiveness of using SPS as eye drops, we performed applied eye irritation tests on rabbits and antibacterial tests for Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans. The eye irritation test was performed according to the toxicity testing regulation of the Korea Food & Drug Administration (2009. 8. 24, KFDA 2009-116. After SPS had been applied on the left eye of the rabbits, eye irritation in the cornea, iris and conjunctiva was observed on the 1st, 2nd, 3rd, 4th & 7th day. After SPS had been dropped on bacterial species that cause keratitis, the minimum inhibition concentration and the size of the inhibition zone were measured. The anti-bacterial potency was also measured by taking the size of inhibition zone. Results: After SPS had been administered on the left eye of the rabbits, none of nine rabbits were found to show abnormal signs or weight changes. After SPS had been administered on the left eye of the rabbits, no eye irritation in the cornea, iris and conjunctiva was observed on the 1st, 2nd, 3rd, 4th & 7th day. No specific response was detected in MIC for bacterial species Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, Aspergillus niger, Fusarium oxysporum, and Candida albicans after SPS had been applied. Conclusions: This study suggests that SPS is a non-toxic and non-irritant medicine that does not cause any of eye irritation in rabbits, but it has no antibacterial effects on bacterial species that are well known to cause keratitis. These results suggest that more research is required on extracts from herbal medicines for treating keratitis.

  12. Prediction of safety critical software operational reliability from test reliability using testing environment factors

    International Nuclear Information System (INIS)

    Jung, Hoan Sung; Seong, Poong Hyun

    1999-01-01

    It has been a critical issue to predict the safety critical software reliability in nuclear engineering area. For many years, many researches have focused on the quantification of software reliability and there have been many models developed to quantify software reliability. Most software reliability models estimate the reliability with the failure data collected during the test assuming that the test environments well represent the operation profile. User's interest is however on the operational reliability rather than on the test reliability. The experiences show that the operational reliability is higher than the test reliability. With the assumption that the difference in reliability results from the change of environment, from testing to operation, testing environment factors comprising the aging factor and the coverage factor are developed in this paper and used to predict the ultimate operational reliability with the failure data in testing phase. It is by incorporating test environments applied beyond the operational profile into testing environment factors. The application results show that the proposed method can estimate the operational reliability accurately. (Author). 14 refs., 1 tab., 1 fig

  13. Study on personnel qualification for non-destructive tests in the field of reactor safety

    International Nuclear Information System (INIS)

    Trusch, K.; Wuestenberg, H.

    1977-01-01

    The training system for non-destructive testing is described, and the available and necessary personnel is analyzed; the personnel required for reactor safety problems is treated separately. On this basis, the subjects discussed in the study - available personnel, personnel requirements, training, training requirements, and suggestions for realisation - are treated in a general manner to begin with and afterwards with a view to specific problems of reactor safety. The methods employed are adapted to this situation. To obtain the necessary empirical data, questionnaires were set up and distributed, and experts in selected business companies and institutions were interviewed who work in the field of reactor safety or do same training in non-destructive testing. (orig.) [de

  14. Testing digital safety system software with a testability measure based on a software fault tree

    International Nuclear Information System (INIS)

    Sohn, Se Do; Hyun Seong, Poong

    2006-01-01

    Using predeveloped software, a digital safety system is designed that meets the quality standards of a safety system. To demonstrate the quality, the design process and operating history of the product are reviewed along with configuration management practices. The application software of the safety system is developed in accordance with the planned life cycle. Testing, which is a major phase that takes a significant time in the overall life cycle, can be optimized if the testability of the software can be evaluated. The proposed testability measure of the software is based on the entropy of the importance of basic statements and the failure probability from a software fault tree. To calculate testability, a fault tree is used in the analysis of a source code. With a quantitative measure of testability, testing can be optimized. The proposed testability can also be used to demonstrate whether the test cases based on uniform partitions, such as branch coverage criteria, result in homogeneous partitions that is known to be more effective than random testing. In this paper, the testability measure is calculated for the modules of a nuclear power plant's safety software. The module testing with branch coverage criteria required fewer test cases if the module has higher testability. The result shows that the testability measure can be used to evaluate whether partitions have homogeneous characteristics

  15. Methods of Certification tests PLC-Networks in Compliance Safety Information

    Directory of Open Access Journals (Sweden)

    A. A. Balaev

    2011-12-01

    Full Text Available The aim of this research was description of the methodology of the audit plc-network to meet the requirements of information security. The technique is based on the provisions of the guidance documents and model FSTEC Russia test object methods of information on safety information.

  16. Operational-safety advantages of LMFBR's: the EBR-II experience and testing program

    International Nuclear Information System (INIS)

    Sackett, J.I.; Lindsay, R.W.; Golden, G.H.

    1982-01-01

    LMFBR's contain many inherent characteristics that simplify control and improve operating safety and reliability. The EBR-II design is such that good advantage was taken of these characteristics, resulting in a vary favorable operating history and allowing for a program of off-normal testing to further demonstrate the safe response of LMFBR's to upsets. The experience already gained, and that expected from the future testing program, will contribute to further development of design and safety criteria for LMFBR's. Inherently safe characteristics are emphasized and include natural convective flow for decay heat removal, minimal need for emergency power and a large negative reactivity feedback coefficient. These characteristics at EBR-II allow for ready application of computer diagnosis and control to demonstrate their effectiveness in response to simulated plant accidents. This latter testing objective is an important part in improvements in the man-machine interface

  17. Final safety and hazards analysis for the Battelle LOCA simulation tests in the NRU reactor

    International Nuclear Information System (INIS)

    Axford, D.J.; Martin, I.C.; McAuley, S.J.

    1981-04-01

    This is the final safety and hazards report for the proposed Battelle LOCA simulation tests in NRU. A brief description of equipment test design and operating procedure precedes a safety analysis and hazards review of the project. The hazards review addresses potential equipment failures as well as potential for a metal/water reaction and evaluates the consequences. The operation of the tests as proposed does not present an unacceptable risk to the NRU Reactor, CRNL personnel or members of the public. (author)

  18. First observational tests of eternal inflation.

    Science.gov (United States)

    Feeney, Stephen M; Johnson, Matthew C; Mortlock, Daniel J; Peiris, Hiranya V

    2011-08-12

    The eternal inflation scenario predicts that our observable Universe resides inside a single bubble embedded in a vast inflating multiverse. We present the first observational tests of eternal inflation, performing a search for cosmological signatures of collisions with other bubble universes in cosmic microwave background data from the WMAP satellite. We conclude that the WMAP 7-year data do not warrant augmenting the cold dark matter model with a cosmological constant with bubble collisions, constraining the average number of detectable bubble collisions on the full sky N(s) < 1.6 at 68% C.L. Data from the Planck satellite can be used to more definitively test the bubble-collision hypothesis.

  19. DHS small-scale safety and thermal testing of improvised explosives-comparison of testing performance

    International Nuclear Information System (INIS)

    Reynolds, J G; Hsu, P C; Sandstrom, M M; Brown, G W; Warner, K F; Phillips, J J; Shelley, T J; Reyes, J A

    2014-01-01

    One of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of improvised materials or homemade explosives (HMEs) to SSST testing, 16 HME materials were compared to three standard military explosives in a proficiency-type round robin study among five laboratories-two DoD and three DOE-sponsored by DHS. The testing matrix has been designed to address problems encountered with improvised materials-powder mixtures, liquid suspensions, partially wetted solids, immiscible liquids, and reactive materials. More than 30 issues have been identified that indicate standard test methods may require modification when applied to HMEs to derive accurate sensitivity assessments needed for developing safe handling and storage practices. This paper presents a generalized comparison of the results among the testing participants, comparison of friction results from BAM (German Bundesanstalt für Materi-alprüfung) and ABL (Allegany Ballistics Laboratory) designed testing equipment, and an overview of the statistical results from the RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) standard tested throughout the proficiency test.

  20. Testing laboratories, its function in ensuring industrial safety

    International Nuclear Information System (INIS)

    Sanchez Fernandez, M.

    2015-01-01

    This article discusses and justifies the development of industrial laboratories (testing and calibration) in Spain, since its embryo, its creation and development, to the present day. Likewise, presents its interrelation with other agents, as well as the legislative and technical framework is application along to the years. Within this development of the sector, highlights the period of the conformity assessment, and consequently its relationship with Industrial safety. Finally, describes the organizational situation of the sector both nationally and internationally. (Author)

  1. Comparison of Domestic Safety Review and European Union(EU) Stress Test After Nuclear Accident in Fukushima Daiichi NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hwa Sung; Kim, Jin Weon [Chosun University, Gwangju (Korea, Republic of)

    2016-05-15

    The European Union(EU) nuclear regulators group established stress test criteria and procedures, and utilities performed a self-review in accordance with those criteria and procedures. For Wolsung nuclear unit-1,the stress test was additionally conducted for deciding the continued operation of NPP, even though the safety review had been conducted after Fukushima NPP accident. Thus, this study is to compares the process, criteria, and results of the safety review performed in domestic NPPs and EU stress test performed in Cernavoda NPP. From the comparisons, the effectiveness and necessity of the stress test to decide the continued operation of NPPs is discussed. and the improvement items for safety enhancement are derived. The comparison showed that the process and review criteria of EU stress test was more systematic and specific than those used in domestic NPPs. But it was indicated that the improvement items resulted from the safety review performed in domestic NPPs are more comprehensive and powerful than EU stress tests (Cernavoda NPP) results. EU stress test for Cernavoda NPP evaluated in 3 fieldsand derived 13 design change items. The 50 improvement items derived from domestic safety review were including the contents of these 13 items.

  2. 10 CFR 32.101 - Schedule B-prototype tests for luminous safety devices for use in aircraft.

    Science.gov (United States)

    2010-01-01

    ....101 Schedule B—prototype tests for luminous safety devices for use in aircraft. An applicant for a... 10 Energy 1 2010-01-01 2010-01-01 false Schedule B-prototype tests for luminous safety devices for use in aircraft. 32.101 Section 32.101 Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES...

  3. The electron test accelerator safety in design and operation

    International Nuclear Information System (INIS)

    McKeown, J.

    1980-06-01

    The Electron Test Accelerator is being designed as an experiment in accelerator physics and technology. With an electron beam power of up to 200 kW the operation of the accelerator presents a severe radiation hazard as well as rf and electrical hazards. The design of the safety system provides fail-safe protection while permitting flexibility in the mode of operation and minimizing administrative controls. (auth)

  4. Handbook of safety assessment of nanomaterials from toxicological testing to personalized medicine

    CERN Document Server

    Fadeel, Bengt

    2014-01-01

    "The Handbook of Safety Assessment of Nanomaterials: From Toxicological Testing to Personalized Medicine provides a comprehensive overview of the state of the art of nanotoxicology and is a unique resource that fills up many knowledge gaps in the toxicity issue of nanomaterials in medical applications. The book is distinguished by up-to-date insights into creating a science-based framework for safety assessment of nanomedicines." -Prof. Yuliang Zhao, National Center for Nanosciences and Technology, China.

  5. Developing and Testing the Health Care Safety Hotline: A Prototype Consumer Reporting System for Patient Safety Events.

    Science.gov (United States)

    Schneider, Eric C; Ridgely, M Susan; Quigley, Denise D; Hunter, Lauren E; Leuschner, Kristin J; Weingart, Saul N; Weissman, Joel S; Zimmer, Karen P; Giannini, Robert C

    2017-06-01

    This article describes the design, development, and testing of the Health Care Safety Hotline, a prototype consumer reporting system for patient safety events. The prototype was designed and developed with ongoing review by a technical expert panel and feedback obtained during a public comment period. Two health care delivery organizations in one metropolitan area collaborated with the researchers to demonstrate and evaluate the system. The prototype was deployed and elicited information from patients, family members, and caregivers through a website or an 800 phone number. The reports were considered useful and had little overlap with information received by the health care organizations through their usual risk management, customer service, and patient safety monitoring systems. However, the frequency of reporting was lower than anticipated, suggesting that further refinements, including efforts to raise awareness by actively soliciting reports from subjects, might be necessary to substantially increase the volume of useful reports. It is possible that a single technology platform could be built to meet a variety of different patient safety objectives, but it may not be possible to achieve several objectives simultaneously through a single consumer reporting system while also establishing trust with patients, caregivers, and providers.

  6. PANDA: A Multipurpose Integral Test Facility for LWR Safety Investigations

    International Nuclear Information System (INIS)

    Paladino, D.; Dreier, J.

    2012-01-01

    The PANDA facility is a large scale, multicompartmental thermal hydraulic facility suited for investigations related to the safety of current and advanced LWRs. The facility is multipurpose, and the applications cover integral containment response tests, component tests, primary system tests, and separate effect tests. Experimental investigations carried on in the PANDA facility have been embedded in international projects, most of which under the auspices of the EU and OECD and with the support of a large number of organizations (regulatory bodies, technical dupport organizations, national laboratories, electric utilities, industries) worldwide. The paper provides an overview of the research programs performed in the PANDA facility in relation to BWR containment systems and those planned for PWR containment systems.

  7. Safety in acoustic emission testing

    International Nuclear Information System (INIS)

    Pollock, A.A.

    2004-01-01

    The human cost of accidents - the loss of family members and friends, and the impairment of life through injuries - makes prevention a very high priority in our society. Especially in the more industrialized countries, where high levels of personal comfort and security are the norm, resources are available to develop safety-enhancing technologies, cultures and management techniques. Thus, safety programs have become a well-established part of the industrial workplace. (author)

  8. Test interval optimization of safety systems of nuclear power plant using fuzzy-genetic approach

    International Nuclear Information System (INIS)

    Durga Rao, K.; Gopika, V.; Kushwaha, H.S.; Verma, A.K.; Srividya, A.

    2007-01-01

    Probabilistic safety assessment (PSA) is the most effective and efficient tool for safety and risk management in nuclear power plants (NPP). PSA studies not only evaluate risk/safety of systems but also their results are very useful in safe, economical and effective design and operation of NPPs. The latter application is popularly known as 'Risk-Informed Decision Making'. Evaluation of technical specifications is one such important application of Risk-Informed decision making. Deciding test interval (TI), one of the important technical specifications, with the given resources and risk effectiveness is an optimization problem. Uncertainty is inherently present in the availability parameters such as failure rate and repair time due to the limitation in assessing these parameters precisely. This paper presents a solution to test interval optimization problem with uncertain parameters in the model with fuzzy-genetic approach along with a case of application from a safety system of Indian pressurized heavy water reactor (PHWR)

  9. Radiation safety in welding and testing

    International Nuclear Information System (INIS)

    King, B.E.; Malaxos, M.; Hartley, B.M.

    1985-01-01

    There are a number of ways of achieving radiation safety in the workplace. The first is by engineering radiation safety into the equipment, providing shielded rooms and safety interlocks. The second is by following safe working procedures. The National Health and Medical Research Council's Code of practice for the control and safe handling of sealed radioactive sources used in industrial radiography (1968) sets out the standards which must be met by equipment to be used in industrial radiography

  10. Safety Significance of the Halden IFA-650 LOCA Test Results

    International Nuclear Information System (INIS)

    Fuketa, Toyoshi; Nagase, Fumihisa; Grandjean, Claude; Petit, Marc; Hozer, Zoltan; Kelppe, Seppo; Khvostov, Grigori; Hafidi, Biya; Therache, Benjamin; Heins, Lothar; Valach, Mojmir; Voglewede, John; Wiesenack, Wolfgang

    2010-01-01

    The safety criteria for loss-of-coolant accidents were defined to ensure that the core would remain coolable. Since the time of the first LOCA experiments, which were largely conducted with fresh fuel, changes in fuel design, the introduction of new cladding materials and in particular the move to high burnup have generated a need to re-examine these criteria and to verify their continued validity. As part of international efforts to this end, the OECD Halden Reactor Project program implemented a LOCA test series. Based on recommendations of a group of experts from the US NRC, EPRI, EDF, IRSN, FRAMATOME-ANP and GNF, the primary objective of the experiments were defined as 1. Measure the extent of fuel (fragment) relocation into the ballooned region and evaluate its possible effect on cladding temperature and oxidation. 2. Investigate the extent (if any) of 'secondary transient hydriding' on the inner side of the cladding above and below the burst region. The fourth test of the series, IFA-650.4 conducted in April 2006, caused particular attention in the international nuclear community. The fuel used in the experiment had a high burnup, 92 MWd/kgU, and a low pre-test hydrogen content of about 50 ppm. The test aimed at and achieved a peak cladding temperature of 850 deg. C. The rod burst occurred at 790 deg. C. The burst caused a marked temperature increase at the lower end and a decrease at the upper end of the system, indicating that fuel relocation had occurred. Subsequent gamma scanning showed that approximately 19 cm of the fuel stack were missing from the upper part of the rod and that fuel had fallen to the bottom of the capsule. PIE at the IFE-Kjeller hot cells corroborated this evidence of substantial fuel relocation. The fact that fuel dispersal could occur upon ballooning and burst, i.e. at cladding temperatures as low as 800 deg. C and thus far lower than the temperature entailed by the current 1200 deg. C / 17% ECR limit, caused concern. The

  11. Verification of FPGA-Signal using the test board which is applied to Safety-related controller

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Youn-Hu; Yoo, Kwanwoo; Lee, Myeongkyun; Yun, Donghwa [SOOSAN ENS, Seoul (Korea, Republic of)

    2016-10-15

    This article aims to provide the verification method for BGA-type FPGA of Programmable Logic Controller (PLC) developed as Safety Class. The logic of FPGA in the control device with Safety Class is the circuit to control overall logic of PLC. Saftety-related PLC must meet the international standard specifications. With this reason, we use V and V according to an international standard in order to secure high reliability and safety. By using this, we are supposed to proceed to a variety of verification courses for extra reliability and safety analysis. In order to have efficient verification of test results, we propose the test using the newly changed BGA socket which can resolve the problems of the conventional socket on this paper. The Verification of processes is divided into verification of Hardware and firmware. That processes are carried out in the unit testing and integration testing. The proposed test method is simple, the effect of cost reductions by batch process. In addition, it is advantageous to measure the signal from the Hi-speed-IC due to its short length of the pins and it was plated with the copper around it. Further, it also to prevent abrasion on the IC ball because it has no direct contact with the PCB. Therefore, it can be actually applied is to the BGA package test and we can easily verify logic as well as easily checking the operation of the designed data.

  12. Dimensions of Safety Climate among Iranian Nurses

    Directory of Open Access Journals (Sweden)

    Z Naghavi Konjin

    2015-10-01

    Full Text Available Background: Workplace safety has been a concern of workers and managers for decades. Measuring safety climate is crucial in improving safety performance. It is also a method of benchmarking safety perception. Objective: To develop and validate a psychometrics scale for measuring nurses' safety climate. Methods: Literature review, subject matter experts and nurse's judgment were used in items developing. Content validity and reliability for new tool were tested by content validity index (CVI and test-retest analysis, respectively. Exploratory factor analysis (EFA with varimax rotation was used to improve the interpretation of latent factors. Results: A 40-item scale in 6 factors was developed, which could explain 55% of the observed variance. The 6 factors included employees' involvement in safety and management support, compliance with safety rules, safety training and accessibility to personal protective equipment, hindrance to safe work, safety communication and job pressure, and individual risk perception. Conclusion: The proposed scale can be used in identifying the needed areas to implement interventions in safety climate of nurses.

  13. Review of domestic and international experience on optimization of tests planning for safety related systems at NPP

    International Nuclear Information System (INIS)

    Skalozubov, V.I.; Komarov, Yu.A.; Kolykanov, V.N.; Kochneva, V.Yu.; Gablaya, T.V.

    2009-01-01

    There are represented the basic requirements of normative and operating documents on test periodicity of safety related systems at NPPs, sets out the theoretical methods of test optimization of the technical systems, and analyses foreign engineering methods for changing test periodicity of the NPP systems. Based on this review analyses further tasks are formulated for improvement of the methodical base of optimization of tests planning for safety related systems

  14. Safety assessment of botanicals and botanical preparations used as ingredients in food supplements: testing an European Food Safety Authority-tiered approach.

    Science.gov (United States)

    Speijers, Gerrit; Bottex, Bernard; Dusemund, Birgit; Lugasi, Andrea; Tóth, Jaroslav; Amberg-Müller, Judith; Galli, Corrado L; Silano, Vittorio; Rietjens, Ivonne M C M

    2010-02-01

    This article describes results obtained by testing the European Food Safety Authority-tiered guidance approach for safety assessment of botanicals and botanical preparations intended for use in food supplements. Main conclusions emerging are as follows. (i) Botanical ingredients must be identified by their scientific (binomial) name, in most cases down to the subspecies level or lower. (ii) Adequate characterization and description of the botanical parts and preparation methodology used is needed. Safety of a botanical ingredient cannot be assumed only relying on the long-term safe use of other preparations of the same botanical. (iii) Because of possible adulterations, misclassifications, replacements or falsifications, and restorations, establishment of adequate quality control is necessary. (iv) The strength of the evidence underlying concerns over a botanical ingredient should be included in the safety assessment. (v) The matrix effect should be taken into account in the safety assessment on a case-by-case basis. (vi) Adequate data and methods for appropriate exposure assessment are often missing. (vii) Safety regulations concerning toxic contaminants have to be complied with. The application of the guidance approach can result in the conclusion that safety can be presumed, that the botanical ingredient is of safety concern, or that further data are needed to assess safety.

  15. Development of a test rig and its application for validation and reliability testing of safety-critical software

    Energy Technology Data Exchange (ETDEWEB)

    Thai, N D; McDonald, A M [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1996-12-31

    This paper describes a versatile test rig developed by AECL for functional testing of safety-critical software used in the process trip computers of the Wolsong CANDU stations. The description covers the hardware and software aspects of the test rig, the test language and its interpreter, and other major testing software utilities such as the test oracle, sampler and profiler. The paper also discusses the application of the rig in the final stages of testing of the process trip computer software, namely validation and reliability tests. It shows how random test cases are generated, test scripts prepared and automatically run on the test rig. The versatility of the rig is further demonstrated in other types of testing such as sub-system tests, verification of the test oracle, testing of newly-developed test script, self-test and calibration. (author). 5 tabs., 10 figs.

  16. Development of a test rig and its application for validation and reliability testing of safety-critical software

    International Nuclear Information System (INIS)

    Thai, N.D.; McDonald, A.M.

    1995-01-01

    This paper describes a versatile test rig developed by AECL for functional testing of safety-critical software used in the process trip computers of the Wolsong CANDU stations. The description covers the hardware and software aspects of the test rig, the test language and its interpreter, and other major testing software utilities such as the test oracle, sampler and profiler. The paper also discusses the application of the rig in the final stages of testing of the process trip computer software, namely validation and reliability tests. It shows how random test cases are generated, test scripts prepared and automatically run on the test rig. The versatility of the rig is further demonstrated in other types of testing such as sub-system tests, verification of the test oracle, testing of newly-developed test script, self-test and calibration. (author). 5 tabs., 10 figs

  17. Effect of Several Negative Rounds of Human Papillomavirus and Cytology Co-testing on Safety Against Cervical Cancer: An Observational Cohort Study.

    Science.gov (United States)

    Castle, Philip E; Kinney, Walter K; Xue, Xiaonan; Cheung, Li C; Gage, Julia C; Zhao, Fang-Hui; Fetterman, Barbara; Poitras, Nancy E; Lorey, Thomas S; Wentzensen, Nicolas; Katki, Hormuzd A; Schiffman, Mark

    2018-01-02

    Current U.S. cervical cancer screening and management guidelines do not consider previous screening history, because data on multiple-round human papillomavirus (HPV) and cytology "co-testing" have been unavailable. To measure cervical cancer risk in routine practice after successive negative screening co-tests at 3-year intervals. Observational cohort study. Integrated health care system (Kaiser Permanente Northern California, Oakland, California). 990 013 women who had 1 or more co-tests from 2003 to 2014. 3- and 5-year cumulative detection of (risk for) cervical intraepithelial neoplasia grade 3, adenocarcinoma in situ, and cervical cancer (≥CIN3) in women with different numbers of negative co-tests, overall and within subgroups defined by previous co-test results or baseline age. Five-year ≥CIN3 risks decreased after each successive negative co-test screening round (0.098%, 0.052%, and 0.035%). Five-year ≥CIN3 risks for an HPV-negative co-test, regardless of the cytology result, nearly matched the performance (reassurance) of a negative co-test for each successive round of screening (0.114%, 0.061%, and 0.041%). By comparison, ≥CIN3 risks for the cytology-negative co-test, regardless of the HPV result, also decreased with each successive round, but 3-year risks were as high as 5-year risks after an HPV-negative co-test (0.199%, 0.065%, and 0.043%). No interval cervical cancer cases were diagnosed after the second negative co-test. Independently, ≥CIN3 risks decreased with age. Length of previous screening interval did not influence future ≥CIN3 risks. Interval-censored observational data. After 1 or more negative cervical co-tests (or HPV tests), longer screening intervals (every 5 years or more) might be feasible and safe. National Cancer Institute Intramural Research Program.

  18. Test Results of a Platform for Safety I and C Systems of SMART MMIS

    International Nuclear Information System (INIS)

    Suh, Yong Suk; Keum, Jong Yong; Jeong, Kwang Il; Lee, Joon Ku; Lee, Sang Seok; Kim, Kwan Woong

    2011-01-01

    SMART (System-integrated Modular Advanced ReacTor), a 330MWt integral pressurized light water reactor that integrates four reactor coolant pumps, one pressurizer, eight steam generators, and one reactor core into a reactor vessel, has been under development at KAERI since 1997. A standard design safety analysis report of the SMART prepared by KAERI was submitted to Korea institute of nuclear safety (KINS) at the end of 2010. KAERI aims to achieve standard design approval (SDA) from KINS by the end of 2011. SMART MMIS has been designed using digital systems. It has digital-based compact control rooms. Its instrumentation and control (I and C) systems are designed using modular equipment connected through datalinks. Non-safety I and C systems are designed based on the commercial distributed control systems. Safety I and C systems are based on a new platform developed by KAERI. The platform is a high-speed digital signal processor (DSP)-based control unit. It plays the role of a module that provides control functions of the safety I and C systems. The test facilities have been developed at KAERI since 2009. This paper presents the development and test results of the platform

  19. PIE on Safety-Tested Loose Particles from Irradiated Compact 4-4-2

    Energy Technology Data Exchange (ETDEWEB)

    Hunn, John D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gerczak, Tyler J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Morris, Robert Noel [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baldwin, Charles A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Montgomery, Fred C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-04-01

    Post-irradiation examination (PIE) is being performed in support of tristructural isotropic (TRISO) coated particle fuel development and qualification for High Temperature Gas-cooled Reactors (HTGRs). This work is sponsored by the Department of Energy Office of Nuclear Energy (DOE-NE) through the Advanced Reactor Technologies (ART) Office under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program. The AGR-1 experiment was the first in a series of TRISO fuel irradiation tests initiated in 2006. The AGR-1 TRISO particles and fuel compacts were fabricated at Oak Ridge National Laboratory (ORNL) in 2006 using laboratory-scale equipment and irradiated for 3 years in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) to demonstrate and evaluate fuel performance under HTGR irradiation conditions. Post-irradiation examination was performed at INL and ORNL to study how the fuel behaved during irradiation, and to test fuel performance during exposure to elevated temperatures at or above temperatures that could occur during a depressurized conduction cooldown event. This report summarizes safety testing and post-safety testing PIE conducted at ORNL on loose particles extracted from irradiated AGR-1 Compact 4-4-2.

  20. Improving safety in small enterprises through an integrated safety management intervention.

    Science.gov (United States)

    Kines, Pete; Andersen, Dorte; Andersen, Lars Peter; Nielsen, Kent; Pedersen, Louise

    2013-02-01

    This study tests the applicability of a participatory behavior-based injury prevention approach integrated with safety culture initiatives. Sixteen small metal industry enterprises (10-19 employees) are randomly assigned to receive the intervention or not. Safety coaching of owners/managers result in the identification of 48 safety tasks, 85% of which are solved at follow-up. Owner/manager led constructive dialogue meetings with workers result in the prioritization of 29 tasks, 79% of which are accomplished at follow-up. Intervention enterprises have significant increases on six of eight safety-perception-survey factors, while comparisons increase on only one factor. Both intervention and comparison enterprises demonstrate significant increases in their safety observation scores. Interview data validate and supplement these results, providing some evidence for behavior change and the initiation of safety culture change. Given that over 95% of enterprises in most countries have less than 20 employees, there is great potential for adapting this integrated approach to other industries. Copyright © 2012 National Safety Council and Elsevier Ltd. All rights reserved.

  1. The ConCom Safety Management Scale: developing and testing a measurement instrument for control-based and commitment-based safety management approaches in hospitals.

    Science.gov (United States)

    Alingh, Carien W; Strating, Mathilde M H; van Wijngaarden, Jeroen D H; Paauwe, Jaap; Huijsman, Robbert

    2018-03-06

    Nursing management is considered important for patient safety. Prior research has predominantly focused on charismatic leadership styles, although it is questionable whether these best characterise the role of nurse managers. Managerial control is also relevant. Therefore, we aimed to develop and test a measurement instrument for control-based and commitment-based safety management of nurse managers in clinical hospital departments. A cross-sectional survey design was used to test the newly developed questionnaire in a sample of 2378 nurses working in clinical departments. The nurses were asked about their perceptions of the leadership behaviour and management practices of their direct supervisors. Psychometric properties were evaluated using confirmatory factor analysis and reliability estimates. The final 33-item questionnaire showed acceptable goodness-of-fit indices and internal consistency (Cronbach's α of the subscales range: 0.59-0.90). The factor structure revealed three subdimensions for control-based safety management: (1) stressing the importance of safety rules and regulations; (2) monitoring compliance; and (3) providing employees with feedback. Commitment-based management consisted of four subdimensions: (1) showing role modelling behaviour; (2) creating safety awareness; (3) showing safety commitment; and (4) encouraging participation. Construct validity of the scale was supported by high factor loadings and provided preliminary evidence that control-based and commitment-based safety management are two distinct yet related constructs. The findings were reconfirmed in a cross-validation procedure. The results provide initial support for the construct validity and reliability of our ConCom Safety Management Scale. Both management approaches were found to be relevant for managing patient safety in clinical hospital departments. The scale can be used to deepen our understanding of the influence of patient safety management on healthcare professionals

  2. Safety system function trend indicator: Theory and test application

    International Nuclear Information System (INIS)

    Azarm, M.A.; Carbonaro, J.F.; Boccio, J.L.; Vesely, W.E.

    1989-01-01

    The purpose of this paper is to summarize research conducted on the development and validation of quantitative indicators of safety performance. This work, performed under the Risk-Based Performance Indicator (RBPI) Project, FIN A-3295, for the Office of Research (RES), is considered part of NRC's Performance Indicator Program which is being coordinated through the Office for the Analysis and Evaluation of Operational Data (AEOD). The program originally focused on risk-based indicators at high levels of safety indices (e.g., core-damage frequency, functional unavailabilities, and sequence monitoring). The program was then redirected towards a more amenable goal, safety system unavailability indicators, mainly due to the lack of PRA models and plant data. In that regard, BNL published a technical report that introduced the concept of cycle-based indicators and also described various alternatives of monitoring safety system unavailabilities. Further simplification of these indicators was requested by NRC to facilitate their applications to all plants in a timely manner. This resulted in the development of Safety System Function Trend (SSFT) indicators which minimize the need for detailed system model as well as component history. The theoretical bases for these indicators were developed through various simulation studies to determine the ease of detecting a trend and/or unacceptable performance. These indicators, along with several other indicators, were then generated and compared using plant data as a part of a test application. The SSFT indicators, specifically, were constructed for a total of eight plants, consisting of two systems per plant. Emphasis was placed on examining relative changes, as well as the indicator's actual level. Both the trend and actual indicator level were found to be important in identifying plants with potential problems

  3. An observational study of road safety around selected primary schools in Ibadan municipality, Oyo State, Southwestern Nigeria.

    Science.gov (United States)

    Sangowawa, Adesola O; Adebiyi, Akindele O; Faseru, Babalola; Popoola, Olusola J

    2012-01-01

    Child pedestrians have been identified as vulnerable road users. Although walking as a means of transport has health and other benefits, it exposes children to the risk of road traffic injuries. This study was conducted to assess the availability of road safety features around government-owned primary schools in Ibadan municipality. A multistage sampling technique was used to select 46 of the 74 schools in the study area. Some (11) of the selected schools were sited within the same premises and shared a common entrance; thus a total of 35 school premises were eventually observed. Trained research assistants observed the school environment around the selected schools for road safety features such as location of schools, presence of "school", "child crossing" and "speed limit" road signs, and presence of traffic calming devices (road bumps or zebra crossing). Five (14%) of the schools were located on major roads and eight (23%) had road signs indicating that a school was nearby. Seven (20%) had road bumps close to the school, 15 (43%) had a warden who assisted children to cross, and none had a zebra crossing. Five (14%) schools had pedestrian sidewalks. The study revealed that the environment around a number of the observed schools in the municipality compromised the pupils' road safety. The local government, school authorities, parents, and road safety professionals need to institute definite measures to enhance the road safety environment around schools in the municipality.

  4. Sub-optimal Testing and Awareness of HCV and HBV Among High Risk Individuals at an Underserved Safety-Net Hospital.

    Science.gov (United States)

    Wong, Robert J; Campbell, Brendan; Liu, Benny; Baden, Rachel; Bhuket, Taft

    2018-02-01

    Sub-optimal screening for chronic hepatitis C virus (HCV) and chronic hepatitis B virus (HBV) among high risk groups delays diagnosis and treatment. We aimed to evaluate overall rates of HCV and HBV screening and patient knowledge of their testing result. Adults age ≥18 years undergoing elective outpatient endoscopy at a large, urban safety-net hospital from July 2015 to July 2016 were prospectively evaluated to determine rates of HCV and HBV testing, the results of those completed tests, and patient knowledge of test results among high risk individuals (as determined by U.S. Preventative Services Task Force). Among 1125 patients (52.3% male, 70.4% foreign-born), 66.5% were high risk for chronic HCV; only 30.9% received prior testing. 14.7% had positive chronic HCV infection. Patients born in the 1945-1965 cohort were more likely to have received prior HCV testing compared to those born outside of this cohort (32.7 vs. 16.9%, p = 0.01). Among patients who received HCV screening, 29.3% were aware of test results. Overall, 61.6% were high risk for chronic HBV; only 25.1% received prior testing. 4.1% were positive for chronic HBV. Compared to Caucasians, Asians (19.0 vs. 44.4%, p HBV testing. Among patients who received prior HBV screening, 18.4% were aware of test results. Less than one-third of high risk patients received HCV and HBV screening among an ethnically diverse safety-net population. Equally low rates of patient knowledge of testing results were observed.

  5. Test of safety injection supply by diesel generator under reactor vessel closed condition

    International Nuclear Information System (INIS)

    Zhang Hao; Bi Fengchuan; Che Junxia; Zhang Jianwen; Yang Bo

    2014-01-01

    The paper studied that the test of diesel generator full load take-up under the condition of actual safety injection and reactor vessel closed in Ningde nuclear project unit l. It is proved that test result accorded with design criteria, meanwhile, the test was removed from the key path of project schedule, which cut a huge cost. (authors)

  6. The School Assessment for Environmental Typology (SAfETy): An Observational Measure of the School Environment.

    Science.gov (United States)

    Bradshaw, Catherine P; Milam, Adam J; Furr-Holden, C Debra M; Johnson, Sarah Lindstrom

    2015-12-01

    School safety is of great concern for prevention researchers, school officials, parents, and students, yet there are a dearth of assessments that have operationalized school safety from an organizational framework using objective tools and measures. Such a tool would be important for deriving unbiased assessments of the school environment, which in turn could be used as an evaluative tool for school violence prevention efforts. The current paper presents a framework for conceptualizing school safety consistent with Crime Prevention through Environmental Design (CPTED) model and social disorganization theory, both of which highlight the importance of context as a driver for adolescents' risk for involvement in substance use and violence. This paper describes the development of a novel observational measure, called the School Assessment for Environmental Typology (SAfETy), which applies CPTED and social disorganizational frameworks to schools to measure eight indicators of school physical and social environment (i.e., disorder, trash, graffiti/vandalism, appearance, illumination, surveillance, ownership, and positive behavioral expectations). Drawing upon data from 58 high schools, we provide preliminary data regarding the validity and reliability of the SAfETy and describe patterns of the school safety indicators. Findings demonstrate the reliability and validity of the SAfETy and are discussed with regard to the prevention of violence in schools.

  7. The road safety audit and road safety inspection.

    NARCIS (Netherlands)

    2007-01-01

    A road safety audit (RSA) and a road safety inspection (RSI) are used to test the safety level of the road infrastructure. The RSA tests the design of new roads or the reconstruction of existing roads, whereas the RSI is used for testing existing roads. An RSA, therefore, aims to 'improve' the road

  8. Preliminary safety evaluation (PSE) for Sodium Storage Facility at the Fast Flux Test Facility

    International Nuclear Information System (INIS)

    Bowman, B.R.

    1994-01-01

    This evaluation was performed for the Sodium Storage Facility (SSF) which will be constructed at the Fast Flux Test Facility (FFTF) in the area adjacent to the South and West Dump Heat Exchanger (DHX) pits. The purpose of the facility is to allow unloading the sodium from the FFTF plant tanks and piping. The significant conclusion of this Preliminary Safety Evaluation (PSE) is that the only Safety Class 2 components are the four sodium storage tanks and their foundations. The building, because of its imminent risk to the tanks under an earthquake or high winds, will be Safety Class 3/2, which means the building has a Safety Class 3 function with the Safety Class 2 loads of seismic and wind factored into the design

  9. Safety Assessment Document for the Spent Reactor Fuel Geologic Storage Test in the Climax Granite Stock at the Nevada Test site

    International Nuclear Information System (INIS)

    1980-01-01

    The objective of the Spent Fuel Geologic Storage Test in the Climax Granite Stock is to evaluate the response of a granitic rock mass to the underground storage of encapsulated spent reactor fuel in a geometry that simulates a module of a large-scale geologic repository. This document reports an assessment of the safety of conducting this test. Descriptions are provided of the geography, meteorology, hydrology, geology, and seismology of the Climax Site; the effects of postulated natural phenomena and other activities at the nevada Test Site on the safety of the test; and the design and operation of the test facility and associated equipment. Evaluations are made of both the radiological and nonradiological impacts of normal operations, abnormal operations, and postulated accidents. It is concluded that conduct of the spent fuel test at the Climax Site will not result in any undue risk to the public, property, environment, or site employees

  10. Safety Test Report for the PWR S/F Dry Storage System

    Energy Technology Data Exchange (ETDEWEB)

    Seo, K. S.; Lee, J. H.; Koo, K. H.; Lee, J. C.; Choi, W. S.; Bang, K. S.; Park, H. Y.; Jang, S. Y

    2008-10-15

    This is contract report conducted by KAERI under the contract with NETEC for safety test for the PWR S/F dry storage system. Leak Test was performed after drop test and turn-over test, the measured leakage rate was lower than allowable leakage rate. It is revealed that the containment integrity of the dry storage system is maintained. In the seismic test, the moving of the model was measured at SRTH seismic response of 0.4 g and 0.8 g. Therefore the seismic test results can be used fully to the test data for verification of the seismic analysis. In the thermal test, the direction of the inlet and outlet of the air has no effect on the heat transfer performance. The passive heat removal system of the horizontal storage module was designed well.

  11. Safety tests of spiral-type lithium-thionyl chloride D-cells

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Kyoji; Mizutani, Minoru (Japan Storage Battery Co., Ltd., Kyoto)

    1989-12-25

    The spiral-type Lithium-Thionyl Chloride D-cell 3360H has no problem at all on safety under normal conditions of its use, however in special severe conditions, a large current flows instantaneously due to its high performance, and danger of an explosion with abrupt heat release is produced. Safety tests have been carried out to confirm the limit of safety performance. Results show abnormal circumstances such as high-rate discharge over 7A, high-rate charging of full discharged cells, nail-penetration, compression with a wedge and heating with a heat tape over 200{degree}C result in hazardous behaviors such as venting, firing and explosion. Therefore, this cell is equipped with proper protecting devices such as overcurrent and thermal protecting fuses to avoid hazardous behaviors. However, the severe conditions of handlings such as dumping into fire and approach to heat source, deformation and rupture by adding an external forces, and applications of too much vibration and impact, should be avoided. 5 refs., 9 figs., 2 tabs.

  12. Lithium-ion batteries for hearing aid applications. II. Pulse discharge and safety tests

    Science.gov (United States)

    Passerini, S.; Coustier, F.; Owens, B. B.

    Rechargeable lithium-ion batteries were designed to meet the power requirements of hearing aid devices (HADs). The batteries were designed in a 312-button cell size, compatible with existing hearing aids. The batteries were tested to evaluate the design and the electrochemical performance, as they relate to a typical hearing aid application. The present report covers the pulse capabilities, cycle life and preliminary safety tests. The results are compared with other battery chemistries: secondary lithium-alloy and nickel-metal hydride batteries and primary Zn-air batteries. The cell AC impedance was stable over the frequency range between 1 and 50 kHz, ranging between 5 Ω at the higher frequency and 12 Ω at the lower extreme. Pulse tests were consistent with these values, as the cells were capable of providing a series of 100 mA pulses of 10-s duration. The safety tests suggest that the design is intrinsically safe with respect to the most common types of abuse conditions.

  13. Randomized controlled trials and real-world observational studies in evaluating cardiovascular safety of inhaled bronchodilator therapy in COPD

    Directory of Open Access Journals (Sweden)

    Kardos P

    2016-11-01

    Full Text Available Peter Kardos,1 Sally Worsley,2 Dave Singh,3 Miguel Román-Rodríguez,4 David E Newby,5 Hana Müllerová2 1Group Practice and Respiratory, Allergy and Sleep Unit, Red Cross Maingau Hospital, Frankfurt, Germany; 2GSK, Stockley Park, Middlesex, 3University of Manchester, Medicines Evaluation Unit, University Hospital of South Manchester NHS Foundation Trust, Manchester, UK; 4Primary Care Respiratory Research Unit, Instituto de Investigación Sanitaria de Palma IdisPa, Palma de Mallorca, Spain; 5BHF Centre for Cardiovascular Science, University of Edinburgh, The Queen’s Medical Research Institute, Edinburgh, UK Abstract: Long-acting muscarinic antagonist (LAMA or long-acting β2-agonist (LABA bronchodilators and their combination are recommended for the maintenance treatment of chronic obstructive pulmonary disease (COPD. Although the efficacy of LAMAs and LABAs has been well established through randomized controlled trials (RCTs, questions remain regarding their cardiovascular (CV safety. Furthermore, while the safety of LAMA and LABA monotherapy has been extensively studied, data are lacking for LAMA/LABA combination therapy, and the majority of the studies that have reported on the CV safety of LAMA/LABA combination therapy were not specifically designed to assess this. Evaluation of CV safety for COPD treatments is important because many patients with COPD have underlying CV comorbidities. However, severe CV and other comorbidities are often exclusion criteria for RCTs, contributing to a lack in external validity and generalizability. Real-world observational studies are another important tool to evaluate the effectiveness and safety of COPD therapies in a broader population of patients and can improve upon the external validity limitations of RCTs. We examine what is already known regarding the CV and cerebrovascular safety of LAMA/LABA combination therapy from RCTs and real-world observational studies, and explore the advantages and

  14. Test study on safety features of station blackout accident for nuclear main pump

    International Nuclear Information System (INIS)

    Liu Xiajie; Wang Dezhong; Zhang Jige; Liu Junsheng; Yang Zhe

    2009-01-01

    The theoretical and experimental studies of reactor coolant pump accidents encountered nation-wide and world-wide were described. To investigate the transient hydrodynamic performance of reactor coolant pump (RCP) during the period of rotational inertia in the station blackout accident, some theoretical and experimental studies were carried out, and the analysis of the test results was presented. The experiment parameters, conditions and test methods were introduced. The flow-rate, rotate speed and vibrations were analyzed emphatically. The quadruplicate polynomial curve equation was used to simulate the flow-rate,rotate speed along with time. The test results indicate that the flow-rate and rotator speed decrease rapidly at the very beginning of cut power and the test results accord with the regulation of safety standard. The vibrant displacement of bearing seat is intensified at the moment of lose power, but after a certain period rotor shaft libration changes. The test and analysis results help to understand the hydrodynamic performance of nuclear primary pump under lost of power accident, and provide the basic reference for safety evaluation. (authors)

  15. Measures ensuring safety of the High Temperature Engineering Test Reactor (HTTR)

    International Nuclear Information System (INIS)

    1998-04-01

    JAERI has conducted research and development of an HTGR type reactor since 1969 under the project of the multi-purpose high-temperate gas-cooled experimental reactor, whose design was changed to the HTTR in 1985. The reactor license was granted by the Government in 1990 and the construction started next year. Various functions and performances have been tested since 1996 and the initial criticality achieved in 1998. This document consists of six chapters, describing safety matters examined in several development phases. The first chapter deals with succession of the multi-purpose experimental reactor technology and its exchange between JAERI and domestic industries. Chapter 2 reviews new technical findings after the licensing which were reflected to the current safety assessment. These technical items are given in the table form of extensive pages. Chapter 3 and 4 describe the performance tests and the criticality access, respectively. Chapter 5 and 6 deal with the detection of fuel failures and helium gas leaks, respectively. (H.Y.)

  16. Finite test sets development method for test execution of safety critical software

    International Nuclear Information System (INIS)

    El-Bordany Ayman; Yun, Won Young

    2014-01-01

    It reads inputs, computes new states, and updates output for each scan cycle. Korea Nuclear Instrumentation and Control System (KNICS) has recently developed a fully digitalized Reactor Protection System (RPS) based on PLD. As a digital system, this RPS is equipped with a dedicated software. The Reliability of this software is crucial to NPPs safety where its malfunction may cause irreversible consequences and affect the whole system as a Common Cause Failure (CCF). To guarantee the reliability of the whole system, the reliability of this software needs to be quantified. There are three representative methods for software reliability quantification, namely the Verification and Validation (V and V) quality-based method, the Software Reliability Growth Model (SRGM), and the test-based method. An important concept of the guidance is that the test sets represent 'trajectories' (a series of successive values for the input variables of a program that occur during the operation of the software over time) in the space of inputs to the software.. Actually, the inputs to the software depends on the state of plant at that time, and these inputs form a new internal state of the software by changing values of some variables. In other words, internal state of the software at specific timing depends on the history of past inputs. Here the internal state of the software which can be changed by past inputs is named as Context of Software (CoS). In a certain CoS, a software failure occurs when a fault is triggered by some inputs. To cover the failure occurrence mechanism of a software, preceding researches insist that the inputs should be a trajectory form. However, in this approach, there are two critical problems. One is the length of the trajectory input. Input trajectory should long enough to cover failure mechanism, but the enough length is not clear. What is worse, to cover some accident scenario, one set of input should represent dozen hours of successive values

  17. Safety and Function Test Report for the Viryd CS8 Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Roadman, J.; Murphy, M.; van Dam, J.

    2013-10-01

    This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. Several turbines were selected for testing at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) as a part of the Small Wind Turbine Independent Testing project. Safety and function testing is one of up to five tests that may be performed on the turbines. Other tests include duration, power performance, acoustic noise, and power quality. Viryd Technologies, Inc. of Austin, Texas, was the recipient of the DOE grant and provided the turbine for testing.

  18. Safety Performance Evaluations for the Vehicle Based Movable Barriers Using Full Scale Crash Tests

    Directory of Open Access Journals (Sweden)

    Jin Minsoo

    2017-01-01

    Full Text Available The present study aims to develop a prototype of large-size movable barriers to protect roadside workers from incoming vehicles to the road work area with the following functions: maximization of work space in the right and left directions, convenient mobility, and minimization of impact without modification of the inside of movable barriers into traffic lanes and perform safety performance assessment on passengers through full scale crash tests. The large movable barrier was divided into folder type and telescope type and the development stage was now at the prototype phase. A full scale crash test was conducted prior to certification test at a level of 90%. The full scale crash test result showed that both types of folder type movable barrier and telescope type movable barrier satisfied the standard of the passenger safety performance evaluation at a level of 90%.

  19. Guidelines for confirmatory inplant tests of safety-relief valve discharges for BWR plants

    International Nuclear Information System (INIS)

    Su, T.M.

    1981-05-01

    Inplant tests of safety/relief valve (SRV) discharges may be required to confirm generically established specifications for SRV loads and the maximum suppression pool temperature, and to evaluate possible effects of plant-unique parameters. These tests are required in those plants which have features that differ substantially from those previously tested. Guidelines for formulating appropriate test matrices, establishing test procedures, selecting necessary instrumentation, and reporting the test results are provided in this report. Guidelines to determine if inplant tests are required on the basis of the plant unique parameters are also included in the report

  20. Some observations about quality control tests of Spect

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.

    1987-01-01

    Some observations about quality control tests done in the tomographic system of Heart Institute are described. Among the tests, the traditional test of quality control with scintillation camera and the specific test for tomography systems are induced. The traditional tests are essential, but not sufficient for evaluating the Spect equipment and the specific tests have been effectuated in controlled conditions. (C.G.C.) [pt

  1. Safety evaluation of the loss of fluid test facility project No. 394

    International Nuclear Information System (INIS)

    1975-05-01

    Assessment of the safety of the LOFT facility and subsequent recommendations have been based on a comparison of the LOFT facility to requirements for commercial power reactors. In this comparison, the many unique features of the LOFT facility were considered including the low power level, the limited operational use as a test reactor, and the remoteness of the site. Based on this assessment, it is concluded, that while the likelihood of an accidental release of fission products may be greater than for a commercial power reactor, the consequences of such a release are reduced by the lower fission product inventory, the remoteness of the site and the capability of evacuating the Idaho National Engineering Laboratory (INEL) and adjacent areas. There is reasonable assurance that the public health and safety will not be endangered due to operation of this facility, specifically: The INEL site is acceptable with respect to location, land use, population distribution, controlled access, hydrology, meteorology, geology and seismology. Sufficient engineered safety features have been included to assure that the potential offsite doses are well within 10 CFR Part 100 guidelines. The LOFT facility has been designed in general accordance with standards, guides and codes which are comparable to those applied to commercial power reactors and any exceptions to these have been based on the unique features of the LOFT facility. Certain matters including the final safety analyses based on detailed component designs, Technical Specifications, LOCE controls and detailed program plan have not been reviewed but we assume will properly be resolved by ERDA, which has the ultimate responsibility for the safety of this facility. Changes to the facility design or program plan such as removal of the fueled Mobile Test Assembly or blowdowns to the containment vessel also will require additional analyses and review. (U.S.)

  2. Extended occupant safety through virtual testing: objectives of the European project VITES

    NARCIS (Netherlands)

    Hoof, J.F.A.M. van; Happee, R.; Baldauf, H.; Puppini, R.; Oakley, C.

    2001-01-01

    Increasingly stringent international passenger safety norms and the need to reduce vehicle body weight for environmental and protection requirements demand efficient and innovative design methods. Computer simulation, or virtual testing, allows an integrated evaluation of these aspects in the early

  3. Explosion overpressure test series: General-Purpose Heat Source development: Safety Verification Test program

    International Nuclear Information System (INIS)

    Cull, T.A.; George, T.G.; Pavone, D.

    1986-09-01

    The General-Purpose Heat Source (GPHS) is a modular, radioisotope heat source that will be used in radioisotope thermoelectric generators (RTGs) to supply electric power for space missions. The first two uses will be the NASA Galileo and the ESA Ulysses missions. The RTG for these missions will contain 18 GPHS modules, each of which contains four 238 PuO 2 -fueled clads and generates 250 W/sub (t)/. A series of Safety Verification Tests (SVTs) was conducted to assess the ability of the GPHS modules to contain the plutonia in accident environments. Because a launch pad or postlaunch explosion of the Space Transportation System vehicle (space shuttle) is a conceivable accident, the SVT plan included a series of tests that simulated the overpressure exposure the RTG and GPHS modules could experience in such an event. Results of these tests, in which we used depleted UO 2 as a fuel simulant, suggest that exposure to overpressures as high as 15.2 MPa (2200 psi), without subsequent impact, does not result in a release of fuel

  4. Laboratory test requesting appropriateness and patient safety

    CERN Document Server

    Blasco, Álvaro; Carratalá, Arturo; Lopez-Garrígos, Maite; Rodriguez-Borja, Enrique

    2016-01-01

    Patient Safety emphasizes the reporting, analysis and prevention of medical errors that very often leads to adverse healthcare situations.1 in 10 patients are impacted by medical errors.The WHO calls the patient safety issue an endemic concern. A number of well-known experts of all areas in the medical field have collectedvery valuable information for a better patient treatment and higher safety culture in all medical disciplines.

  5. Final safety analysis report for the Ground Test Accelerator (GTA), Phase 2

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-10-01

    This document is the second volume of a 3 volume safety analysis report on the Ground Test Accelerator (GTA). The GTA program at the Los Alamos National Laboratory (LANL) is the major element of the national Neutral Particle Beam (NPB) program, which is supported by the Strategic Defense Initiative Office (SDIO). A principal goal of the national NPB program is to assess the feasibility of using hydrogen and deuterium neutral particle beams outside the Earth`s atmosphere. The main effort of the NPB program at Los Alamos concentrates on developing the GTA. The GTA is classified as a low-hazard facility, except for the cryogenic-cooling system, which is classified as a moderate-hazard facility. This volume consists of failure modes and effects analysis; accident analysis; operational safety requirements; quality assurance program; ES&H management program; environmental, safety, and health systems critical to safety; summary of waste-management program; environmental monitoring program; facility expansion, decontamination, and decommissioning; summary of emergency response plan; summary plan for employee training; summary plan for operating procedures; glossary; and appendices A and B.

  6. Quench and safety tests on a toroidal field coil of Tore Supra

    International Nuclear Information System (INIS)

    Ciazynski, D.; Cure, C.; Duchateau, J.L.

    1987-01-01

    As a part of the safety analysis of the magnet, three quenches have been initiated in one of the TF coils in the Saclay test facility. While transporting a given current, the coil is insulated from the refrigerator: the temperatures of the helium and of the coil increase slowly on account of thermal losses. At the current sharing temperature a quench rapidly propagates and the protection system makes the coil discharge in the dump resistor. At three levels of current, electrical, thermal and hydraulic measurements have been performed. All these results are taken into account for the safety design of TORE SUPRA

  7. CSER 96-014: criticality safety of project W-151, 241-AZ-101 retrieval system process test

    Energy Technology Data Exchange (ETDEWEB)

    Vail, T.S., Fluor Daniel Hanford

    1997-02-06

    This Criticality Safety Evaluation Report (CSER) documents a review of the criticality safety implications of a process test to be performed in tank 241-AZ-101 (101-AZ). The process test will determine the effectiveness of the retrieval system for mobilization of solids and the practicality of the system for future use in the underground storage tanks at Hanford. The scope of the CSER extends only to the testing and operation of the mixer pumps and does not include the transfer of waste from the tank. Justification is provided that a nuclear criticality is extremely unlikely, if not impossible, in this tank.

  8. Performance and Safety Tests on Samsung 18650 Li-ion Cells: Two Cell Designs

    Science.gov (United States)

    Deng, Yi; Jeevarajan, Judith; Rehm, Raymond; Bragg, Bobby; Zhang, Wenlin

    2002-01-01

    In order to meet the applications for space shuttle in future, two types of Samsung cells, with capacity 1800 mAh and 2000 mAh, have been investigated. The studies focused on: (1) Performance tests: completed 250 cycles at various combinations of charge/discharge C rates and discharge capacity measurements at various temperatures; and (2) Safety tests: overcharge and overdischarge, heat abuse, short circuit, internal and external short, and vibration, vacuum, and drop tests

  9. Observational study of food safety practices in retail deli departments.

    Science.gov (United States)

    Lubran, M B; Pouillot, R; Bohm, S; Calvey, E M; Meng, J; Dennis, S

    2010-10-01

    In order to improve the safety of refrigerated ready-to-eat food products prepared at retail deli departments, a better understanding of current practices in these establishments is needed. Food employees in deli departments at six chain and three independent retail establishments in Maryland and Virginia were observed, using notational analysis, as they prepared deli products for sale. The frequency of contact with objects and deli products before sale, hand washing and glove changing during preparation, and equipment, utensil, and surface cleaning and sanitizing was determined. Compliance with the U.S. Food and Drug Administration's 2005 model Food Code recommendations, which must be adopted by the individual state and local jurisdictions that are responsible for directly regulating retail establishments, was also assessed. Observations indicated there were a large number of actions for which hand washing was recommended at independent and chain stores (273 recommended of 1,098 total actions and 439 recommended of 3,073 total actions, respectively). Moreover, 67% (295 of 439) of the actions for which hand washing was recommended at the chain stores and 86% (235 of 273) of those at the independent stores resulted from employees touching non-food contact surfaces prior to handling ready-to-eat food. Compliance with hand washing recommendations was generally low and varied depending on store type with independent stores exhibiting lower compliance than chain stores (5 instances of compliance for 273 recommended actions and 73 instances of compliance for 439 recommended actions, respectively). Potential risk mitigation measures that may reduce the frequency of hand washing actions needed during ready-to-eat food preparation in retail deli departments are discussed. More research is needed to determine the impact of such measures on food safety.

  10. Certification test for safety of new fuel transportation package

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Sugawa, Osami; Suga, Masao.

    1993-01-01

    The objective of this certification test is to prove the safety of new fuel transportation package against a fire of actual size caused by traffic accidents. After the fire test, the fuel assemblies were covered with coal-tar like material vaporized from anti-shock material used in the container. Surface color of BWR-type fuel assembly was dark grey that is supposed to be the color of oxide of Zircaloy. As for PWR-type fuel assembly, the condition encountered during fire test caused no change to the outlook of the rod element. Both the BWR and PWR type fuel rod elements showed no deformation and were completely sound. Therefore it may be concluded that the container protected the mimic fuel assemblies against fire of 30 minutes duration and caused no damage. This report is the result of the above experiments and examinations, and we appreciate the cooperation of those who are concerned. (J.P.N.)

  11. Tool for assistance in testing the safety logic section of nuclear plants

    International Nuclear Information System (INIS)

    Boulc'h, J.; Meur, M. le; Collart, J.M.; Segalard, J.; Uberschlag, J.

    1986-01-01

    The analysis of the protection system logic section (SPIN) of the PALUEL plant performed manually have led to the study of a logical tool for testing the safety logic section having or having not failures. It is a dynamic analyser which from a terminal in a sharing time system will be able to generate testing sequences, to simulate a processor and its environment and to analyse the logic sections with their workable code

  12. Safety Design Strategy for the Advanced Test Reactor Emergency Firewater Injection System Replacement Project

    International Nuclear Information System (INIS)

    Duckwitz, Noel

    2011-01-01

    In accordance with the requirements of U.S. Department of Energy (DOE) Order 413.3B, 'Program and Project Management for the Acquisition of Capital Assets,' safety must be integrated into the design process for new or major modifications to DOE Hazard Category 1, 2, and 3 nuclear facilities. The intended purpose of this requirement involves the handling of hazardous materials, both radiological and chemical, in a way that provides adequate protection to the public, workers, and the environment. Requirements provided in DOE Order 413.3B and DOE Order 420.1B, 'Facility Safety,' and the expectations of DOE-STD-1189-2008, 'Integration of Safety into the Design Process,' provide for identification of hazards early in the project and use of an integrated team approach to design safety into the facility. This safety design strategy provides the basic safety-in-design principles and concepts that will be used for the Advanced Test Reactor Reliability Sustainment Project. While this project does not introduce new hazards to the ATR, it has the potential for significant impacts to safety-related systems, structures, and components that are credited in the ATR safety basis and are being replaced. Thus the project has been determined to meet the definition of a major modification and is being managed accordingly.

  13. Thermal-Hydraulic Tests for Reactor Core Safety

    International Nuclear Information System (INIS)

    Chun, Se Young; Chung, Moon Ki; Baek, Won Pil and others

    2005-04-01

    The reflood experiments for single rod annulus geometry have been performed to investigate the effect of spacer grid on thermal-hydraulics under reflood conditions. The reflood experimental loop for 6x6 rod bundle with a spacer grid developed in Korea has been provided. About 8000 data points for Post-CHF heat transfer have been obtained from the experiments About 1400 CHF data points for 3x3 Water and 5x5 Freon rod bundles have been obtained. The existing evaluation methodology for core safety under return-to-power conditions has been investigated using KAERI low flow CHF database. The hydraulic tests for turbulence mixing characteristics in subchannel of 5x5 rod bundle have been carried out using advanced measurement technique, LVD and the database for various spacer grids have been provided. In order to measure the turbulence mixing characteristics in details, the hydraulic loop with a magnified 5x5 rod bundle has been prepared. The database which was constructed through a systematic thermal hydraulic tests for the reflood phenomenon, CHF, Post-CHF is surely to be useful to the industry field, the regulation body and the development of thermal-hydraulic analysis code

  14. Impact of closed Brayton cycle test results on gas cooled reactor operation and safety

    International Nuclear Information System (INIS)

    Wright, St.A.; Pickard, P.S.

    2007-01-01

    This report summarizes the measurements and model predictions for a series of tests supported by the U.S. Department of Energy that were performed using the recently constructed Sandia Brayton Loop (SBL-30). From the test results we have developed steady-state power operating curves, controls methodologies, and transient data for normal and off-normal behavior, such as loss of load events, and for decay heat removal conditions after shutdown. These tests and models show that because the turbomachinery operates off of the temperature difference (between the heat source and the heat sink), that the turbomachinery can continue to operate (off of sensible heat) for long periods of time without auxiliary power. For our test hardware, operations up to one hour have been observed. This effect can provide significant operations and safety benefits for nuclear reactors that are coupled to a Brayton cycles because the operating turbomachinery continues to provide cooling to the reactor. These capabilities mean that the decay-heat removal can be accommodated by properly managing the electrical power produced by the generator/alternator. In some conditions, it may even be possible to produce sufficient power to continue operating auxiliary systems including the waste heat circulatory system. In addition, the Brayton plant impacts the consequences of off-normal and accident events including loss of load and loss of on-site power. We have observed that for a loss of load or a loss of on-site power event, with a reactor scram, the transient consists initially of a turbomachinery speed increase to a new stable operating point. Because the turbomachinery is still spinning, the reactor is still being cooled provided the ultimate heat sink remains available. These highly desirable operational characteristics were observed in the Sandia Brayton loop. This type of behavior is also predicted by our models. Ultimately, these results provide the designers the opportunity to design gas

  15. Improving construction site safety through leader-based verbal safety communication.

    Science.gov (United States)

    Kines, Pete; Andersen, Lars P S; Spangenberg, Soren; Mikkelsen, Kim L; Dyreborg, Johnny; Zohar, Dov

    2010-10-01

    The construction industry is one of the most injury-prone industries, in which production is usually prioritized over safety in daily on-site communication. Workers have an informal and oral culture of risk, in which safety is rarely openly expressed. This paper tests the effect of increasing leader-based on-site verbal safety communication on the level of safety and safety climate at construction sites. A pre-post intervention-control design with five construction work gangs is carried out. Foremen in two intervention groups are coached and given bi-weekly feedback about their daily verbal safety communications with their workers. Foremen-worker verbal safety exchanges (experience sampling method, n=1,693 interviews), construction site safety level (correct vs. incorrect, n=22,077 single observations), and safety climate (seven dimensions, n=105 questionnaires) are measured over a period of up to 42 weeks. Baseline measurements in the two intervention and three control groups reveal that foremen speak with their workers several times a day. Workers perceive safety as part of their verbal communication with their foremen in only 6-16% of exchanges, and the levels of safety at the sites range from 70-87% (correct observations). Measurements from baseline to follow-up in the two intervention groups reveal that safety communication between foremen and workers increases significantly in one of the groups (factor 7.1 increase), and a significant yet smaller increase is found when the two intervention groups are combined (factor 4.6). Significant increases in the level of safety are seen in both intervention groups (7% and 12% increases, respectively), particularly in regards to 'access ways' and 'railings and coverings' (39% and 84% increases, respectively). Increases in safety climate are seen in only one of the intervention groups with respect to their 'attention to safety.' No significant trend changes are seen in the three control groups on any of the three measures

  16. Safety test results of lithium-thionyl chloride wound-type cells

    Science.gov (United States)

    Vallin, D.; Broussely, M.

    1989-05-01

    Increase in the use of spirally-wound, lithium-thionyl chloride cells is currently limited because of unsafe incidents which have been reported during the early stage of development of this product. Today, it is believed that these cells are safe over a wide range of operating conditions if properly designed. The paper describes the external and internal SAFT design of Li-SOCl2LSH series cells, as well as the results of safety tests.

  17. Irradiation Test Plan and Safety Analysis of the Fatigue Capsule(05S-05K)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Man Soon; Kim, B. G.; Kang, Y. H.; Choo, K. N.; Sohn, J. M.; Park, S. J.; Shin, Y. T.; Seo, C. K

    2007-01-15

    In this report, the design, fabrication, the out-pile test and the irradiation test plan of the fatigue capsule 05S-05K were described and the safety aspect during the design, fabrication and irradiation test was reviewed. A cyclic load device necessary for the fatigue test was newly designed and manufactured. By using the cyclic load device the performance test and the preliminary fatigue test were performed with STS316L specimen of {phi}1.8 mm x 12.5 mm gage length under the same condition(550 .deg. C) as the temperature of the specimen during the irradiation test. As a result of the test, the fracture of the specimen occurs at a total of 70,120 cycles, at which the displacement was 2.02 mm. The reactivity effect was reviewed and an analysis for the structural and thermal integrity was performed to review the safety of the capsule, which will be irradiated at a temperature higher than 550 .deg. C And the thermal analysis shows that the temperatures of the parts are less than the melting temperatures of the corresponding materials. The structural analysis considering this temperature shows that the combined stress on the outer tube is less than the allowable stress limits and so the structural integrity is maintained.

  18. Safety evaluation for packaging (onsite) plutonium recycle test reactor graphite cask

    Energy Technology Data Exchange (ETDEWEB)

    Romano, T.

    1997-09-29

    This safety evaluation for packaging (SEP) provides the evaluation necessary to demonstrate that the Plutonium Recycle Test Reactor (PRTR) Graphite Cask meets the requirements of WHC-CM-2-14, Hazardous Material Packaging and Shipping, for transfer of Type B, fissile, non-highway route controlled quantities of radioactive material within the 300 Area of the Hanford Site. The scope of this SEP includes risk, shieldling, criticality, and.tiedown analyses to demonstrate that onsite transportation safety requirements are satisfied. This SEP also establishes operational and maintenance guidelines to ensure that transport of the PRTR Graphite Cask is performed safely in accordance with WHC-CM-2-14. This SEP is valid until October 1, 1999. After this date, an update or upgrade to this document is required.

  19. Safety evaluation for packaging (onsite) plutonium recycle test reactor graphite cask

    International Nuclear Information System (INIS)

    Romano, T.

    1997-01-01

    This safety evaluation for packaging (SEP) provides the evaluation necessary to demonstrate that the Plutonium Recycle Test Reactor (PRTR) Graphite Cask meets the requirements of WHC-CM-2-14, Hazardous Material Packaging and Shipping, for transfer of Type B, fissile, non-highway route controlled quantities of radioactive material within the 300 Area of the Hanford Site. The scope of this SEP includes risk, shieldling, criticality, and.tiedown analyses to demonstrate that onsite transportation safety requirements are satisfied. This SEP also establishes operational and maintenance guidelines to ensure that transport of the PRTR Graphite Cask is performed safely in accordance with WHC-CM-2-14. This SEP is valid until October 1, 1999. After this date, an update or upgrade to this document is required

  20. NASA Engineering and Safety Center (NESC) Enhanced Melamine (ML) Foam Acoustic Test (NEMFAT)

    Science.gov (United States)

    McNelis, Anne M.; Hughes, William O.; McNelis, Mark E.

    2014-01-01

    The NASA Engineering and Safety Center (NESC) funded a proposal to achieve initial basic acoustic characterization of ML (melamine) foam, which could serve as a starting point for a future, more comprehensive acoustic test program for ML foam. A project plan was developed and implemented to obtain acoustic test data for both normal and enhanced ML foam. This project became known as the NESC Enhanced Melamine Foam Acoustic Test (NEMFAT). This document contains the outcome of the NEMFAT project.

  1. A methodological study to compare survey-based and observation-based evaluations of organisational and safety cultures and then compare both approaches with markers of the quality of care.

    Science.gov (United States)

    Freeth, D; Sandall, J; Allan, T; Warburton, F; Berridge, E J; Mackintosh, N; Rogers, M; Abbott, S

    2012-05-01

    %) within ± 0.5; one large difference]. Two commonly used scales had high levels of positive responses, suggesting positive climates or social desirability bias. Strand B: scoring on a four-point scale was feasible. Observational evaluation of teamwork culture was good but too limited for evaluating organisational culture. Strand C: a total of 359-399 cases were audited per condition. The results varied widely between different markers for the same condition, so selection matters. Each site performed well on some markers but not others, with few consistent patterns. Some national guidelines were contested. Comparisons: the comparison of safety climate (survey) and teamwork culture (observation) revealed a moderately low correlation (r = 0.316) and good agreement [SD differences 1.082; 7 (44%) within ±0.5; one large difference]. The comparison of safety climate (survey) and performance (audit) revealed lower correlation (r = 0.150, i.e. relationship not linear) but reasonably good agreement [SD differences 0.992; 9 (56%) within ± 0.5; two large differences]. Comparisons between performance (audit) and both organisational climate (survey) and teamwork culture (observation) showed negligible correlations (culture (observations) are better indicators of performance than organisational climate (surveys) or attempts to evaluate organisational culture from time-limited observations. Scoring unobtrusive, time-limited observations to evaluate teamwork culture is feasible, but the instrument developed for this study needs further testing. A refined observation-based measure would be useful to augment or replace surveys. The National Institute for Health Research Health Technology Assessment programme.

  2. Environmental testing of an experimental digital safety channel

    International Nuclear Information System (INIS)

    Korsah, K.; Tanaka, T.J.; Wilson, T.L. Jr.; Wood, R.T.

    1996-09-01

    This document presents the results of environmental stress tests performed on an experimental digital safety channel (EDSC) assembled at the Oak Ridge National Laboratory (ORNL) as part of the NRC-sponsored Qualification of Advanced Instrumentation and Controls (W) System program. The objective of this study is to investigate failure modes and vulnerabilities of microprocessor-based technologies when subjected to environmental stressors. The study contributes to the technical basis for environmental qualification of safety-related digital I ampersand C systems. The EDSC employs technologies and digital subsystems representative of those proposed for use in advanced light-water reactors (ALWRs) or for retrofits in existing plants. Subsystems include computers, electrical and optical serial communication links, fiber-optic network links, analog-to-digital and digital-to-analog converters, and multiplexers. The EDSC was subjected to selected stressors that are a potential risk to digital equipment in a mild environment. The selected stressors were electromagnetic and radio-frequency interference (EMYRFI), temperature, humidity, and smoke exposure. The stressors were applied over ranges that were considerably higher than what the channel is likely to experience in a normal nuclear power plant environment. Ranges of stress were selected at a sufficiently high level to induce errors so that failure modes that are characteristic of the technologies employed could be identified

  3. Zero-inflated Poisson model based likelihood ratio test for drug safety signal detection.

    Science.gov (United States)

    Huang, Lan; Zheng, Dan; Zalkikar, Jyoti; Tiwari, Ram

    2017-02-01

    In recent decades, numerous methods have been developed for data mining of large drug safety databases, such as Food and Drug Administration's (FDA's) Adverse Event Reporting System, where data matrices are formed by drugs such as columns and adverse events as rows. Often, a large number of cells in these data matrices have zero cell counts and some of them are "true zeros" indicating that the drug-adverse event pairs cannot occur, and these zero counts are distinguished from the other zero counts that are modeled zero counts and simply indicate that the drug-adverse event pairs have not occurred yet or have not been reported yet. In this paper, a zero-inflated Poisson model based likelihood ratio test method is proposed to identify drug-adverse event pairs that have disproportionately high reporting rates, which are also called signals. The maximum likelihood estimates of the model parameters of zero-inflated Poisson model based likelihood ratio test are obtained using the expectation and maximization algorithm. The zero-inflated Poisson model based likelihood ratio test is also modified to handle the stratified analyses for binary and categorical covariates (e.g. gender and age) in the data. The proposed zero-inflated Poisson model based likelihood ratio test method is shown to asymptotically control the type I error and false discovery rate, and its finite sample performance for signal detection is evaluated through a simulation study. The simulation results show that the zero-inflated Poisson model based likelihood ratio test method performs similar to Poisson model based likelihood ratio test method when the estimated percentage of true zeros in the database is small. Both the zero-inflated Poisson model based likelihood ratio test and likelihood ratio test methods are applied to six selected drugs, from the 2006 to 2011 Adverse Event Reporting System database, with varying percentages of observed zero-count cells.

  4. Safety considerations for continuous hydrogen production test apparatus with capacity of 50 N-litter hydrogen per hour

    International Nuclear Information System (INIS)

    Onuki, Kaoru; Akino, Norio; Shimizu, Saburo; Nakajima, Hayato; Higashi, Shunichi; Kubo, Shinji

    2001-03-01

    Since the thermochemical hydrogen production Iodine-Sulfur process decomposes water into hydrogen and oxygen using toxic chemicals such as sulfuric acid, iodine and hydriodic acid, safety considerations are very important in its research and development. Therefore, before construction of continuous hydrogen production test apparatus with capacity of 50 N-litter hydrogen per hour, comprehensive safety considerations were carried out to examine the design and construction works of the test apparatus, and the experimental plans using the apparatus. Emphasis was given on the safety considerations on prevention of breakage of glasswares and presumable abnormalities, accidents and their countermeasures. This report summarizes the results of the considerations. (author)

  5. Comparison of in-plant performance test data with analytic prediction of reactor safety system injection transient (U)

    International Nuclear Information System (INIS)

    Roy, B.N.; Neill, C.H. Jr.

    1993-01-01

    This paper compares the performance test data from injection transients for both of the subsystems of the Supplementary Safety System of the Savannah River Site production reactor with analytical predictions from an in-house thermal hydraulic computer code. The code was initially developed for design validation of the new Supplementary Safety System subsystem, but is shown to be equally capable of predicting the performance of the Supplementary Safety System existing subsystem even though the two subsystem transient injections have marked differences. The code itself was discussed and its validation using prototypic tests with simulated fluids was reported in an earlier paper (Roy and Nomm 1991)

  6. Two important safety-related verification tests in the design of Qinshan NPP 600 MWe reactor

    International Nuclear Information System (INIS)

    Li Pengzhou; Li Tianyong; Yu Danping; Sun Lei

    2005-01-01

    This paper summarizes two most important verification tests performed in the design of reactor of Qinshan NPP Phase II: seismic qualification test of control rod drive line (CRDL), flow-induced vibration test of reactor internals both in 1:5 scaled model and on-site measurement during heat function testing (HFT). Both qualification tests proved that the structural design of the reactor has large safety margin. (authors)

  7. PC based manual and safety logic card test setup for 235 MWe PHWRs

    International Nuclear Information System (INIS)

    Chandgadkar, G.M.; Kohli, A.K.; Agarwal, R.G.; Chandra, Rajesh

    1992-01-01

    Fuel handling controls for 235 MWe PHWR make use of Manual and Logic cards (MLCs) for providing safety interlocks. These cards consist of various type of logic blocks. By connecting these logic blocks all the safety interlocks required for fuel handling controls have been provided. Previously trouble shooting of these cards was done by means of logic probe. Since the method was manual, it was laborious and time consuming. PC based test setup has overcome this drawback and detects the fault at the component level within few seconds. It also gives printout of status of faulty MLC cards. Here motherboard has been designed having slots for insertion of MLC cards. The input/output connection of these cards are coming to two 50 pin FRC connectors. PC communicates through 144 line digital input/output card with MLC card under test. Software is user friendly and outputs suitable input patterns to the card under test and checks for output pattern. It compares this output pattern with compare pattern and detects the fault and displays the symptoms. This system is currently in use at test facility for fuelling machine for 235 MWe PHWR reactor at Refuelling Technology Division, Hall-7. This test setup has been proposed for use at NAPP and future reactors. (author). 4 figs., 1 annexure

  8. Assessing medical students' perceptions of patient safety: the medical student safety attitudes and professionalism survey.

    Science.gov (United States)

    Liao, Joshua M; Etchegaray, Jason M; Williams, S Tyler; Berger, David H; Bell, Sigall K; Thomas, Eric J

    2014-02-01

    To develop and test the psychometric properties of a survey to measure students' perceptions about patient safety as observed on clinical rotations. In 2012, the authors surveyed 367 graduating fourth-year medical students at three U.S. MD-granting medical schools. They assessed the survey's reliability and construct and concurrent validity. They examined correlations between students' perceptions of organizational cultural factors, organizational patient safety measures, and students' intended safety behaviors. They also calculated percent positive scores for cultural factors. Two hundred twenty-eight students (62%) responded. Analyses identified five cultural factors (teamwork culture, safety culture, error disclosure culture, experiences with professionalism, and comfort expressing professional concerns) that had construct validity, concurrent validity, and good reliability (Cronbach alphas > 0.70). Across schools, percent positive scores for safety culture ranged from 28% (95% confidence interval [CI], 13%-43%) to 64% (30%-98%), while those for teamwork culture ranged from 47% (32%-62%) to 74% (66%-81%). They were low for error disclosure culture (range: 10% [0%-20%] to 27% [20%-35%]), experiences with professionalism (range: 7% [0%-15%] to 23% [16%-30%]), and comfort expressing professional concerns (range: 17% [5%-29%] to 38% [8%-69%]). Each cultural factor correlated positively with perceptions of overall patient safety as observed in clinical rotations (r = 0.37-0.69, P safety behavioral intent item. This study provided initial evidence for the survey's reliability and validity and illustrated its applicability for determining whether students' clinical experiences exemplify positive patient safety environments.

  9. Dynamic responses of connections in road safety barriers

    International Nuclear Information System (INIS)

    Bayton, D.A.F.; Long, R.; Fourlaris, G.

    2009-01-01

    Bolted road safety barrier connections utilise slotted holes that are perpendicular to the direction of the safety barrier beam. Due to the clearance between the slotted holes and the bolts, a varying amount of slippage is seen before contact with the edge of the slot is made. The stiffness characteristics of bolted road safety barrier connections have been examined with a representative test coupon that incorporates a full size safety barrier connection slot to industry standard dimensions. Previous research work has successfully determined the stiffness characteristics of the bolted connections at quasi-static strain rates. Representative non-linear finite element models of the bolted test coupons have been constructed. When compared to the laboratory results the initial stiffness, maximum force and displacement of the bolted connections are similar to the finite element model predictions. Current investigations have moved onto strain rates comparable to those observed in actual vehicle crash tests. Explicit dynamic finite element (FE) models have been constructed and validated, using experimental data produced using a series of high strain rate laboratory tests for a number of bolt configurations

  10. Integrated vehicle-based safety systems light-vehicle field operational test key findings report.

    Science.gov (United States)

    2011-01-01

    "This document presents key findings from the light-vehicle field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michigan Transportat...

  11. An update to inplace testing of safety/relief valves utilizing lift assist technology

    International Nuclear Information System (INIS)

    Heorman, K.R.

    1992-01-01

    Inplace testing of safety and relief valves with lift-assist devices has received mixed reviews from nuclear power plant testing personnel. While many plants use the technology, most limit its use to testing main steam safety valves (even though both OM-1-1981 and PTC 25.3-1976 allow its use for several different service applications). Test coordinator concerns regarding the technology range from lift set point accuracy and repeatability to the quality of the test result output. In addition, OM-1-1981 and PTC 25.3-1976 differ in their approach to the technology. The reasons for the differences between PTC 25.3-1976 and OM-1-1981 are discussed along with additional considerations applicable to the use of the technology in testing liquid service valves. This paper shows that lift assist technology is capable of determining lift set points within the accuracy requirements of OM-1 and PTC 25.3. It also demonstrates that the technology should not be limited to compressible service systems. Also, improvements in test repeatability and output quality are discussed as a function of the assist device design used and valve characteristics. Lift assist testing is often preferred over inplace testing that uses direct system pressure. It is often more cost efficient than bench testing because it does not require removal of critical systems from service and transportation of components. Also, duplicating system temperatures and other environmental factors is not an issue during inplace testing. Valve testing that once required an outage and maintenance period can now be conducted prior to such periods. This approach minimizes the possibility of failures becoming critical path limiting items

  12. Sled Tests Using the Hybrid III Rail Safety ATD and Workstation Tables for Passenger Trains

    Science.gov (United States)

    2017-08-01

    The Hybrid III Rail Safety (H3-RS) anthropomorphic test device (ATD) is a crash test dummy developed in the United Kingdom to evaluate abdomen and lower thorax injuries that occur when passengers impact workstation tables during train accidents. The ...

  13. Revision of nuclear power plants safety systems' routine testing assigned periodicity during the design extension period

    International Nuclear Information System (INIS)

    Skalozubov, V.I.; Kozlov, Yi.L.; Chulkyin, O.O.

    2017-01-01

    When nuclear power plants safety systems thermal equipment operation extending, a necessary requirement shall rely on revising the scheduled equipment tests frequency to optimize those tests schedule taking into account the equipment remained lifespan. On the one hand, there exists a need for tests frequency increase to detect ''hidden'' failures, and on the another, frequent tests cause a premature wear of the equipment. Proposed is an original method for optimizing the frequency of NPPs safety systems thermal engineering equipment testing. Essential in the proposed method is the optimization criterion chosen: index of security system failure probability non-exceedance during the beyond-design operating period as referred to the failure probability expected considering the equipment residual resource during the design operating period. The developed method implementation when applied to NPPs safety systems operated beyond the design service life at nuclear power plants with WWER-1000 series reactors, allowed to establish that the optimal tests frequency makes half the designed one when the equipment service life is extended by five years and three times less that the designed frequency when subject lifespan extended by 10 years.

  14. General-Purpose Heat Source Safety Verification Test program: Edge-on flyer plate tests

    International Nuclear Information System (INIS)

    George, T.G.

    1987-03-01

    The radioisotope thermoelectric generator (RTG) that will supply power for the Galileo and Ulysses space missions contains 18 General-Purpose Heat Source (GPHS) modules. The GPHS modules provide power by transmitting the heat of 238 Pu α-decay to an array of thermoelectric elements. Each module contains four 238 PuO 2 -fueled clads and generates 250 W(t). Because the possibility of a launch vehicle explosion always exists, and because such an explosion could generate a field of high-energy fragments, the fueled clads within each GPHS module must survive fragment impact. The edge-on flyer plate tests were included in the Safety Verification Test series to provide information on the module/clad response to the impact of high-energy plate fragments. The test results indicate that the edge-on impact of a 3.2-mm-thick, aluminum-alloy (2219-T87) plate traveling at 915 m/s causes the complete release of fuel from capsules contained within a bare GPHS module, and that the threshold velocity sufficient to cause the breach of a bare, simulant-fueled clad impacted by a 3.5-mm-thick, aluminum-alloy (5052-T0) plate is approximately 140 m/s

  15. Technology, safety, and costs of decommissioning reference nuclear research and test reactors. Appendices

    International Nuclear Information System (INIS)

    Konzek, G.J.; Ludwick, J.D.; Kennedy, W.E. Jr.; Smith, R.I.

    1982-03-01

    Safety and Cost Information is developed for the conceptual decommissioning of two representative licensed nuclear research and test reactors. Three decommissioning alternatives are studied to obtain comparisons between costs (in 1981 dollars), occupational radiation doses, potential radiation dose to the public, and other safety impacts. The alternatives considered are: DECON (immediate decontamination), SAFSTOR (safe storage followed by deferred decontamination), and EMTOMB (entombment). The study results are presented in two volumes. Volume 2 (Appendices) contains the detailed data that support the results given in Volume 1, including unit-component data

  16. Technology, safety, and costs of decommissioning reference nuclear research and test reactors. Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Konzek, G.J.; Ludwick, J.D.; Kennedy, W.E. Jr.; Smith, R.I.

    1982-03-01

    Safety and Cost Information is developed for the conceptual decommissioning of two representative licensed nuclear research and test reactors. Three decommissioning alternatives are studied to obtain comparisons between costs (in 1981 dollars), occupational radiation doses, potential radiation dose to the public, and other safety impacts. The alternatives considered are: DECON (immediate decontamination), SAFSTOR (safe storage followed by deferred decontamination), and EMTOMB (entombment). The study results are presented in two volumes. Volume 2 (Appendices) contains the detailed data that support the results given in Volume 1, including unit-component data.

  17. Evaluating effectiveness and safety toward electronic cigarette among Malaysian vapers: One-month observational study

    Directory of Open Access Journals (Sweden)

    Azizur Rahman

    2016-01-01

    Conclusion: A month follow-up showed a good smoking cessation rate among Malaysian vapers mainly in single users, whereas less number of quitters but the high reduction in tobacco cigarette consumption observed in dual users without any harmful effects. Furthermore, extended period studies are warranted to confirm its long-term safety and effectiveness among different Malaysian population.

  18. Energetic Materials Center Report--Small-Scale Safety and Thermal Testing Evaluation of Butyl Nitrate

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Energetic Materials Center; Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Energetic Materials Center

    2013-04-26

    Butyl Nitrate (BN) was examined by Small-Scale Safety and Thermal (SSST) Testing techniques to determine its sensitivity to impact, friction, spark and thermal exposure simulating handling and storage conditions. Under the conditions tested, the BN exhibits thermal sensitivity above 150 °C, and does not exhibit sensitive to impact, friction or spark.

  19. Learning from positively deviant wards to improve patient safety: an observational study protocol.

    Science.gov (United States)

    Baxter, Ruth; Taylor, Natalie; Kellar, Ian; Lawton, Rebecca

    2015-12-11

    Positive deviance is an asset-based approach to improvement which has recently been adopted to improve quality and safety within healthcare. The approach assumes that solutions to problems already exist within communities. Certain groups or individuals identify these solutions and succeed despite having the same resources as others. Within healthcare, positive deviance has previously been applied at individual or organisational levels to improve specific clinical outcomes or processes of care. This study explores whether the positive deviance approach can be applied to multidisciplinary ward teams to address the broad issue of patient safety among elderly patients. Preliminary work analysed National Health Service (NHS) Safety Thermometer data from 34 elderly medical wards to identify 5 'positively deviant' and 5 matched 'comparison' wards. Researchers are blinded to ward status. This protocol describes a multimethod, observational study which will (1) assess the concurrent validity of identifying positively deviant elderly medical wards using NHS Safety Thermometer data and (2) generate hypotheses about how positively deviant wards succeed. Patient and staff perceptions of safety will be assessed on each ward using validated surveys. Correlation and ranking analyses will explore whether this survey data aligns with the routinely collected NHS Safety Thermometer data. Staff focus groups and researcher fieldwork diaries will be completed and qualitative thematic content analysis will be used to generate hypotheses about the strategies, behaviours, team cultures and dynamics that facilitate the delivery of safe patient care. The acceptability and sustainability of strategies identified will also be explored. The South East Scotland Research Ethics Committee 01 approved this study (reference: 14/SS/1085) and NHS Permissions were granted from all trusts. Findings will be published in peer-reviewed, scientific journals, and presented at academic conferences. This study

  20. Safety test results of lithium-thionyl chloride wound-type cells

    Energy Technology Data Exchange (ETDEWEB)

    Vallin, D.; Broussely, M. (British Columbia Univ., Vancouver (Canada))

    1989-05-01

    Increase in the use of spirally-wound, lithium-thionyl chloride cells is currently limited because of unsafe incidents which have been reported during the early stage of development of this product. Today, it is believed that these cells are safe over a wide range of operating conditions if properly designed. The paper describes the external and internal SAFT design of Li-SOCl2LSH series cells, as well as the results of safety tests. 6 refs.

  1. Advancing the Science of Developmental Neurotoxicity (DNT) Testing for Better Safety Evaluation

    DEFF Research Database (Denmark)

    Bal-Price, Anna; Coecke, Sandra; Costa, Lucio

    2012-01-01

    Bal-Price AK, Coecke S, Costa L, Crofton KM, Fritsche E, Goldberg A, Grandjean P, Lein PJ, Li A, Lucchini R, Mundy WR, Padilla S, Persico A, Seiler AEM, Kreysa J. Conference Report: Advancing the Science of Developmental Neurotoxicity (DNT) Testing for Better Safety Evaluation. Altex 2012: 29: 202-15....

  2. Radiation legacy of nuclear tests at the Semipalatinsk test site in the light of requirements ensuring radiation safety performance

    International Nuclear Information System (INIS)

    Logachev, V.A.; Logacheva, L.A.

    2005-01-01

    Peculiarities of nuclear tests radiation legacy at the Semipalatinsk test site (STS) are shown in the light of performance of requirements ensuring radiation safety, decrease radiation contamination levels in environment and minimize exposure of radiation for population residing contaminated areas by radioactive fallout. The paper provides data on characterization of peculiarities of the STS operation legacy based on review of archival data of the former 3-d General Administration under USSR Ministry of Health. (author)

  3. Current state of the construction of SPARC test facility for observing hydrogen′s behavior

    Energy Technology Data Exchange (ETDEWEB)

    Na, Young Su; Hong, Seong-Ho; Park, Ki Han; Hong, Seong-Wan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Hydrogen combustion can make a dynamic load, which can cause severe damage to a structure or facility. Many studies on hydrogen behavior, such as distribution, combustion and mitigation, have been conducted since the TMI accident, and they were recently summarized in. A large-scaled experimental facility is required for simulating the complex severe accident phenomena in a closed containment building. We are preparing the test facility, called the SPARC (Spray, Aerosol, Recombiner, Combustion), to resolve the international open issues regarding hydrogen risk as well as the validation of the Korean PAR (Passive Auto-catalytic Recombiner). This paper summarized the previous study submitted to the NUTHOS-11, which introduced the SPARC test facility. KAERI (Korea Atomic Energy Research Institute) is preparing a test facility, called the SPARC for an assessment of the containment integrity under a severe accident. In the SPARC test facility, the hydrogen behavior such as mixing with steam and air, distribution, and combustion will be observed under various thermal-hydraulic conditions. We will carry out the performance tests of the safety systems such as the spray, cooling fan, PAR, and igniter. The SPARC test facility consists of a pressure vessel with a 9.5 m height and 3.4 m diameter, and an operating system to control and measure the thermal hydraulic conditions. In a commissioning test, we verified the controllable thermal conditions. It took about 8,400 seconds to increase up to 5 bar. The increment rate of the atmosphere temperature is about 34° C/h from room temperature to 100° C.

  4. LIMBO computer code for analyzing coolant-voiding dynamics in LMFBR safety tests

    International Nuclear Information System (INIS)

    Bordner, G.L.

    1979-10-01

    The LIMBO (liquid metal boiling) code for the analysis of two-phase flow phenomena in an LMFBR reactor coolant channel is presented. The code uses a nonequilibrium, annular, two-phase flow model, which allows for slip between the phases. Furthermore, the model is intended to be valid for both quasi-steady boiling and rapid coolant voiding of the channel. The code was developed primarily for the prediction of, and the posttest analysis of, coolant-voiding behavior in the SLSF P-series in-pile safety test experiments. The program was conceived to be simple, efficient, and easy to use. It is particularly suited for parametric studies requiring many computer runs and for the evaluation of the effects of model or correlation changes that require modification of the computer program. The LIMBO code, of course, lacks the sophistication and model detail of the reactor safety codes, such as SAS, and is therefore intended to compliment these safety codes

  5. The need to optimize inservice testing and inspection to enhance safety

    International Nuclear Information System (INIS)

    Perry, J.A.

    1996-01-01

    Welcome to the Fourth U.S. Nuclear Regulatory Commission and American Society of Mechanical Engineers (USNRC/ASME) Symposium on Valve and Pump Testing in Nuclear Power Plants. This symposium provides a forum to exchange information on technical and regulatory issues associated with the testing of valves and pumps used in nuclear power plants. Progress made since the last symposium will be discussed along with various methods for in service testing of valves and pumps. Active participation by industry representatives, regulators and consultants will entail discussion of a broad array of ideas and points of view regarding how to improve the in service testing of valves and pumps at nuclear power plants. One of the challenges faced is the need to optimize the in service testing and inspection to enhance safety, operability and reliability. The author addresses this challenge from an ASME Nuclear Codes and Standards point of view

  6. The need to optimize inservice testing and inspection to enhance safety

    Energy Technology Data Exchange (ETDEWEB)

    Perry, J.A.

    1996-12-01

    Welcome to the Fourth U.S. Nuclear Regulatory Commission and American Society of Mechanical Engineers (USNRC/ASME) Symposium on Valve and Pump Testing in Nuclear Power Plants. This symposium provides a forum to exchange information on technical and regulatory issues associated with the testing of valves and pumps used in nuclear power plants. Progress made since the last symposium will be discussed along with various methods for in service testing of valves and pumps. Active participation by industry representatives, regulators and consultants will entail discussion of a broad array of ideas and points of view regarding how to improve the in service testing of valves and pumps at nuclear power plants. One of the challenges faced is the need to optimize the in service testing and inspection to enhance safety, operability and reliability. The author addresses this challenge from an ASME Nuclear Codes and Standards point of view.

  7. Coincident steam generator tube rupture and stuck-open safety relief valve carryover tests: MB-2 steam generator transient response test program

    International Nuclear Information System (INIS)

    Garbett, K.; Mendler, O.J.; Gardner, G.C.; Garnsey, R.; Young, M.Y.

    1987-03-01

    In PWR steam generator tube rupture (SGTR) faults, a direct pathway for the release of radioactive fission products can exist if there is a coincident stuck-open safety relief valve (SORV) or if the safety relief valve is cycled. In addition to the release of fission products from the bulk steam generator water by moisture carryover, there exists the possibility that some primary coolant may be released without having first mixed with the bulk water - a process called primary coolant bypassing. The MB-2 Phase II test program was designed specifically to identify the processes for droplet carryover during SGTR faults and to provide data of sufficient accuracy for use in developing physical models and computer codes to describe activity release. The test program consisted of sixteen separate tests designed to cover a range of steady-state and transient fault conditions. These included a full SGTR/SORV transient simulation, two SGTR overfill tests, ten steady-state SGTR tests at water levels ranging from very low levels in the bundle up to those when the dryer was flooded, and three moisture carryover tests without SGTR. In these tests the influence of break location and the effect of bypassing the dryer were also studied. In a final test the behavior with respect to aerosol particles in a dry steam generator, appropriate to a severe accident fault, was investigated

  8. Addressing conflicts of interest in nanotechnology oversight: lessons learned from drug and pesticide safety testing

    International Nuclear Information System (INIS)

    Elliott, Kevin C.; Volz, David C.

    2012-01-01

    Financial conflicts of interest raise significant challenges for those working to develop an effective, transparent, and trustworthy oversight system for assessing and managing the potential human health and ecological hazards of nanotechnology. A recent paper in this journal by Ramachandran et al., J Nanopart Res, 13:1345–1371 (2011) proposed a two-pronged approach for addressing conflicts of interest: (1) developing standardized protocols and procedures to guide safety testing; and (2) vetting safety data under a coordinating agency. Based on past experiences with standardized test guidelines developed by the international Organization for Economic Cooperation and Development (OECD) and implemented by national regulatory agencies such as the U.S. Environmental Protection Agency (EPA) and Food and Drug Administration (FDA), we argue that this approach still runs the risk of allowing conflicts of interest to influence toxicity tests, and it has the potential to commit regulatory agencies to outdated procedures. We suggest an alternative approach that further distances the design and interpretation of safety studies from those funding the research. In case the two-pronged approach is regarded as a more politically feasible solution, we also suggest three lessons for implementing this strategy in a more dynamic and effective manner.

  9. Addressing conflicts of interest in nanotechnology oversight: lessons learned from drug and pesticide safety testing

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, Kevin C., E-mail: ke@sc.edu [University of South Carolina, Department of Philosophy, USC NanoCenter (United States); Volz, David C. [University of South Carolina, Department of Environmental Health Sciences, Arnold School of Public Health (United States)

    2012-01-15

    Financial conflicts of interest raise significant challenges for those working to develop an effective, transparent, and trustworthy oversight system for assessing and managing the potential human health and ecological hazards of nanotechnology. A recent paper in this journal by Ramachandran et al., J Nanopart Res, 13:1345-1371 (2011) proposed a two-pronged approach for addressing conflicts of interest: (1) developing standardized protocols and procedures to guide safety testing; and (2) vetting safety data under a coordinating agency. Based on past experiences with standardized test guidelines developed by the international Organization for Economic Cooperation and Development (OECD) and implemented by national regulatory agencies such as the U.S. Environmental Protection Agency (EPA) and Food and Drug Administration (FDA), we argue that this approach still runs the risk of allowing conflicts of interest to influence toxicity tests, and it has the potential to commit regulatory agencies to outdated procedures. We suggest an alternative approach that further distances the design and interpretation of safety studies from those funding the research. In case the two-pronged approach is regarded as a more politically feasible solution, we also suggest three lessons for implementing this strategy in a more dynamic and effective manner.

  10. Addressing conflicts of interest in nanotechnology oversight: lessons learned from drug and pesticide safety testing

    Science.gov (United States)

    Elliott, Kevin C.; Volz, David C.

    2012-01-01

    Financial conflicts of interest raise significant challenges for those working to develop an effective, transparent, and trustworthy oversight system for assessing and managing the potential human health and ecological hazards of nanotechnology. A recent paper in this journal by Ramachandran et al., J Nanopart Res, 13:1345-1371 (2011) proposed a two-pronged approach for addressing conflicts of interest: (1) developing standardized protocols and procedures to guide safety testing; and (2) vetting safety data under a coordinating agency. Based on past experiences with standardized test guidelines developed by the international Organization for Economic Cooperation and Development (OECD) and implemented by national regulatory agencies such as the U.S. Environmental Protection Agency (EPA) and Food and Drug Administration (FDA), we argue that this approach still runs the risk of allowing conflicts of interest to influence toxicity tests, and it has the potential to commit regulatory agencies to outdated procedures. We suggest an alternative approach that further distances the design and interpretation of safety studies from those funding the research. In case the two-pronged approach is regarded as a more politically feasible solution, we also suggest three lessons for implementing this strategy in a more dynamic and effective manner.

  11. Use of animals for toxicology testing is necessary to ensure patient safety in pharmaceutical development.

    Science.gov (United States)

    Mangipudy, Raja; Burkhardt, John; Kadambi, Vivek J

    2014-11-01

    There is an active debate in toxicology literature about the utility of animal testing vis-a-vis alternative in vitro paradigms. To provide a balanced perspective and add to this discourse it is important to review the current paradigms, explore pros and cons of alternatives, and provide a vision for the future. The fundamental goal of toxicity testing is to ensure safety in humans. In this article, IQ Consortium DruSafe, while submitting the view that nonclinical testing in animals is an important and critical component of the risk assessment paradigm in developing new drugs, also discusses its views on alternative approaches including a roadmap for what would be required to enhance the utilization of alternative approaches in the safety assessment process. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Safety testing of monoclonal antibodies in non-human primates: Case studies highlighting their impact on human risk assessment.

    Science.gov (United States)

    Brennan, Frank R; Cavagnaro, Joy; McKeever, Kathleen; Ryan, Patricia C; Schutten, Melissa M; Vahle, John; Weinbauer, Gerhard F; Marrer-Berger, Estelle; Black, Lauren E

    2018-01-01

    Monoclonal antibodies (mAbs) are improving the quality of life for patients suffering from serious diseases due to their high specificity for their target and low potential for off-target toxicity. The toxicity of mAbs is primarily driven by their pharmacological activity, and therefore safety testing of these drugs prior to clinical testing is performed in species in which the mAb binds and engages the target to a similar extent to that anticipated in humans. For highly human-specific mAbs, this testing often requires the use of non-human primates (NHPs) as relevant species. It has been argued that the value of these NHP studies is limited because most of the adverse events can be predicted from the knowledge of the target, data from transgenic rodents or target-deficient humans, and other sources. However, many of the mAbs currently in development target novel pathways and may comprise novel scaffolds with multi-functional domains; hence, the pharmacological effects and potential safety risks are less predictable. Here, we present a total of 18 case studies, including some of these novel mAbs, with the aim of interrogating the value of NHP safety studies in human risk assessment. These studies have identified mAb candidate molecules and pharmacological pathways with severe safety risks, leading to candidate or target program termination, as well as highlighting that some pathways with theoretical safety concerns are amenable to safe modulation by mAbs. NHP studies have also informed the rational design of safer drug candidates suitable for human testing and informed human clinical trial design (route, dose and regimen, patient inclusion and exclusion criteria and safety monitoring), further protecting the safety of clinical trial participants.

  13. Observer POD for radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kanzler, Daniel; Mueller, Christina; Bertovic, Marija [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Pitkaenen, Jorma [Posiva Oy, Eurajoki (Finland)

    2013-07-01

    The radiographic testing is an important non-destructive testing method, especially in industrial areas where people could be injured in case of failing of a component. There it is a mighty method to find volumetric defects. As bigger the penetrated length of the defect in the component is, as bigger is the radiographic contrast. The detectability of volumetric defects in its turn is not only depending on the contrast but also on the noise, the defect area and its shape. The currently applied POD approach uses mostly only the contrast and the noise as detection threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the area of the defect. The presentation shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data. This approach was developed within a joint project with the company POSIVA, which is constructing a final depository for high active nuclear fuels in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam welds of the copper canisters. The copper canisters will be used in the depository as a corrosion barrier within the waste management concept. (Published as a poster session.)

  14. The Self-Calibration Test of flowmeter installed in STELLA(Sodium Integral Effect Test Loop for Safety Simulation and Assessment) facility

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Minhwan; Jeong, Ji-Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The objective of this study is to describe the procedure of the self-calibration test for the flowmeters and to analyze the result of the test. In this work, the test procedure of the self-calibration of two flowmeters (FT-101, FT-102) installed in STELLA facility was described and the test result was analyzed. In regard to the long-term SFR development plan, a large-scale sodium thermal-hydraulic test project is being progressed by KAERI. This project is called STELLA (Sodium Integral Effect Test Loop for Safety Simulation and Assessment), and it is proceeding by adopting the QA (Quality Assurance) program. Due to the specificity of an experiment using sodium(Na) categorized as Class 3(pyrophoric material and water-prohibiting substance) by the Safety Control of Dangerous Substances Act, it is necessary to apply QA in consideration of the sodium experiment environment in certain parts. The one of them is about calibration of measuring instrument such as a flowmeter, thermocouple and pressure gauge. It is described in the QAP (Quality Assurance Procedures) of KAERI that calibration work should be conducted in accordance with self-calibration procedures in a special case where conventional calibration is not practicable. The calibration of two flowmeters (FT-101, FT-102) installed in STELLA facility is the typical example. As a result of test, it was confirmed that the flowmeters meet the pass criterion. Therefore, it was concluded that the flowmeters maintain instrument capacity a year ago.

  15. Full-Length High-Temperature Severe Fuel Damage Test No. 5: Final safety analysis

    International Nuclear Information System (INIS)

    Lanning, D.D.; Lombardo, N.J.; Panisko, F.E.

    1993-09-01

    This report presents the final safety analysis for the preparation, conduct, and post-test discharge operation for the Full-Length High Temperature Experiment-5 (FLHT-5) to be conducted in the L-24 position of the National Research Universal (NRU) Reactor at Chalk River Nuclear Laboratories (CRNL), Ontario, Canada. The test is sponsored by an international group organized by the US Nuclear Regulatory Commission. The test is designed and conducted by staff from Pacific Northwest Laboratory with CRNL staff support. The test will study the consequences of loss-of-coolant and the progression of severe fuel damage

  16. Preliminary design of safety and interlock system for indian test facility of diagnostic neutral beam

    International Nuclear Information System (INIS)

    Tyagi, Himanshu; Soni, Jignesh; Yadav, Ratnakar; Bandyopadhyay, Mainak; Rotti, Chandramouli; Gahlaut, Agrajit; Joshi, Jaydeep; Parmar, Deepak; Bansal, Gourab; Pandya, Kaushal; Chakraborty, Arun

    2016-01-01

    Highlights: • Indian Test Facility being built to characterize DNB for ITER delivery. • Interlock system required to safeguard the investment incurred in building the facility and protecting ITER deliverable components. • Interlock levels upto 3IL-3 identified. • Safety instrumented system for occupational safety being designed. Safety I&C functions of SIL-2 identified. • The systems are based on ITER PIS and PSS design guidelines. - Abstract: Indian Test Facility (INTF) is being built in Institute For Plasma Research to characterize Diagnostic Neutral Beam in co-operation with ITER Organization. INTF is a complex system which consists of several plant systems like beam source, gas feed, vacuum, cryogenics, high voltage power supplies, high power RF generators, mechanical systems and diagnostics systems. Out of these, several INTF components are ITER deliverable, that is, beam source, beam line components and power supplies. To ensure successful operation of INTF involving integrated operation of all the constituent plant systems a matured Data Acquisition and Control System (DACS) is required. The INTF DACS is based on CODAC platform following on PCDH (Plant Control Design Handbook) guidelines. The experimental phases involve application of HV power supplies (100 KV) and High RF power (∼800 KW) which will produce energetic beam of maximum power 6MW within the facility for longer durations. Hence the entire facility will be exposed tohigh heat fluxes and RF radiations. To ensure investment protection and to provide occupational safety for working personnel a matured Safety and Interlock system is required for INTF. The Safety and Interlock systems are high-reliability I&C systems devoted completely to the specific functions. These systems will be separate from the conventional DACS of INTF which will handle the conventional control and acquisition functions. Both, the Safety and Interlock systems are based on IEC 61511 and IEC 61508 standards as

  17. Preliminary design of safety and interlock system for indian test facility of diagnostic neutral beam

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, Himanshu, E-mail: htyagi@iter-india.org [ITER-India, Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Soni, Jignesh [Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Yadav, Ratnakar; Bandyopadhyay, Mainak; Rotti, Chandramouli [ITER-India, Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Gahlaut, Agrajit [Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Joshi, Jaydeep; Parmar, Deepak [ITER-India, Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Bansal, Gourab; Pandya, Kaushal; Chakraborty, Arun [Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India)

    2016-11-15

    Highlights: • Indian Test Facility being built to characterize DNB for ITER delivery. • Interlock system required to safeguard the investment incurred in building the facility and protecting ITER deliverable components. • Interlock levels upto 3IL-3 identified. • Safety instrumented system for occupational safety being designed. Safety I&C functions of SIL-2 identified. • The systems are based on ITER PIS and PSS design guidelines. - Abstract: Indian Test Facility (INTF) is being built in Institute For Plasma Research to characterize Diagnostic Neutral Beam in co-operation with ITER Organization. INTF is a complex system which consists of several plant systems like beam source, gas feed, vacuum, cryogenics, high voltage power supplies, high power RF generators, mechanical systems and diagnostics systems. Out of these, several INTF components are ITER deliverable, that is, beam source, beam line components and power supplies. To ensure successful operation of INTF involving integrated operation of all the constituent plant systems a matured Data Acquisition and Control System (DACS) is required. The INTF DACS is based on CODAC platform following on PCDH (Plant Control Design Handbook) guidelines. The experimental phases involve application of HV power supplies (100 KV) and High RF power (∼800 KW) which will produce energetic beam of maximum power 6MW within the facility for longer durations. Hence the entire facility will be exposed tohigh heat fluxes and RF radiations. To ensure investment protection and to provide occupational safety for working personnel a matured Safety and Interlock system is required for INTF. The Safety and Interlock systems are high-reliability I&C systems devoted completely to the specific functions. These systems will be separate from the conventional DACS of INTF which will handle the conventional control and acquisition functions. Both, the Safety and Interlock systems are based on IEC 61511 and IEC 61508 standards as

  18. Technology, safety, and costs of decommissioning reference nuclear research and test reactors. Main report

    International Nuclear Information System (INIS)

    Konzek, G.J.; Ludwick, J.D.; Kennedy, W.E. Jr.; Smith, R.I.

    1982-03-01

    Safety and Cost Information is developed for the conceptual decommissioning of two representative licensed nuclear research and test reactors. Three decommissioning alternatives are studied to obtain comparisons between costs (in 1981 dollars), occupational radiation doses, potential radiation dose to the public, and other safety impacts. The alternatives considered are: DECON (immediate decontamination), SAFSTOR (safe storage followed by deferred decontamination), and ENTOMB (entombment). The study results are presented in two volumes. Volume 1 (Main Report) contains the results in summary form

  19. An investigation of fluid mixing with safety injection in advanced reactors

    International Nuclear Information System (INIS)

    Cha, Jong Hee; Won, Soon Yean; Chung, Moon Ki; Jun, Hyung Gil

    1994-01-01

    The objective of this work is to investigate the fluid mixing phenomena in aspect of pressurized thermal shock(PTS) in an advanced PWR vessel downcomer during transient cooldown with safety injection. It provides comparison of fluid mixing characteristics between AP 600 DVI, designed by Westinghouse, and ABB CE System 80+ DVI, and the effects of deflector at the reactor downcomer. In order to investigate the fluid mixing phenomena in the downcomer of an advanced PWR, the flow visualization tests and the salt concentration tests were conducted in a 1/7-scale acrylic transparent model, which was designed and built based on AP 600 reactor geometry. The behaviour of the safety injection flow in downcomer associated with mixing phenomenon can be observed during visualization test, and time-dependent mixing rate between safety injection fluid and existing coolant can be determined with concentration test. Visualization tests were performed by the dye injection method. The results of concentration measurements were compared with the calculation using the REMIX code. During the tests, difference between AP 600 DVI flow and ABB CE System 80+ DVI flow and the effect of the deflector were observed

  20. The approaches of safety design and safety evaluation at HTTR (High Temperature Engineering Test Reactor)

    International Nuclear Information System (INIS)

    Iigaki, Kazuhiko; Saikusa, Akio; Sawahata, Hiroaki; Shinozaki, Masayuki; Tochio, Daisuke; Honma, Fumitaka; Tachibana, Yukio; Iyoku, Tatsuo; Kawasaki, Kozo; Baba, Osamu

    2006-06-01

    Gas Cooled Reactor has long history of nuclear development, and High Temperature Gas Cooled Reactor (HTGR) has been expected that it can be supply high temperature energy to chemical industry and to power generation from the points of view of the safety, the efficiency, the environment and the economy. The HTGR design is tried to installed passive safety equipment. The current licensing review guideline was made for a Low Water Reactor (LWR) on safety evaluation therefore if it would be directly utilized in the HTGR it needs the special consideration for the HTGR. This paper describes that investigation result of the safety design and the safety evaluation traditions for the HTGR, comparison the safety design and safety evaluation feature for the HTGT with it's the LWR, and reflection for next HTGR based on HTTR operational experiment. (author)

  1. Experimental observation of a multi-dimensional mixing behavior of steam-water flow in the MIDAS test facility

    International Nuclear Information System (INIS)

    Kweon, T. S.; Yun, B. J.; Ah, D. J.; Ju, I. C.; Song, C. H.; Park, J. K.

    2001-01-01

    Multi-dimensional thermal-hydraulic hehavior, such as ECC (Emergency Core Cooling) bypass, ECC penetration, steam-water condensation and accumulated water level, in an annular downcomer of a PWR (Pressurized Water Reactor) reactor vessel with a DVI(Direct Vessel Injection) injection mode is presented based on the experimental observations in the MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) steam-water facility. From the steady-state tests to similate a late reflood phase of LBLOCA (Large Break Loss-of-Coolant Accidents), major thermal-hydraulic phenomena in the downcomer are quantified under a wide range of test conditions. Especially, isothermal lines show well multi-dimensional phenomena of phase interaction between steam and water in the annulus downcomer. Overall test results show that multi-dimensional thermal-hydraulic behaviors occur in the downcomer annulus region as expected. The MIDAS test facility is a steam-water separate effect test facility, which is 1/4.93 linearly scaled-down of a 1400 MWe PWR type of nuclear reactor, with focusing on understanding multi-dimensional thermal-hydraulic phenomena in annulus downcomer with various types of safety injection location during refill or reflood phase of a LBLOCA in PWR

  2. The Fast Flux Test Facility built on safety

    International Nuclear Information System (INIS)

    1989-01-01

    No other high-tech industry has grown as fast as the nuclear industry. The information available to the general public has not kept pace with the rapid growth of nuclear data---its growth has outpaced its media image and the safety of nuclear facilities has become a highly debated issue. This book is an attempt to bridge the gap between the high-tech information of the nuclear industry and its understanding by the general public. It explains the three levels of defense at the Fast Flux Test Facility (FFTF) and why these levels provide an acceptable margin to protect the general public and on-site personnel, while achieving FFTF's mission to provide research and development for the US Department of Energy

  3. 78 FR 67206 - Qualification Tests for Safety-Related Actuators in Nuclear Power Plants

    Science.gov (United States)

    2013-11-08

    ... Nuclear Power Plants AGENCY: Nuclear Regulatory Commission. ACTION: Revision to regulatory guide; issuance..., ``Qualification Tests for Safety-Related Actuators in Nuclear Power Plants.'' This RG is being revised to provide... Operators Installed Inside the Containment of Nuclear Power Plants,'' dated January 1974. ADDRESSES: Please...

  4. The safety of food products requires X-ray testing

    International Nuclear Information System (INIS)

    Lardiere, C.

    2017-01-01

    Food safety through standards and regulations imposes food products to be tested for the presence of alien elements. So far metal detectors have been used to detect metal parts, now they have been progressively replaced with X-ray scanners that allow the detection of a lot more contaminants. The improvement of algorithms for image processing combined with the availability of ever more powerful PC have led to the routine use of X-ray testing on industrial processes. Technological progress has made X-ray testing more efficient: while previously a power of 500 W was necessary to cross a 10 cm thickness of water, now only 100 W is necessary. The main advantage of X-ray testing is to be able to test food even packed in metal containers and to detect if the container is deformed. Another advantages is to be able to detect a lot of elements like pieces of glass, small stones or bits of bones. The minimal size to be detected is 0.5 mm for stainless steels and 2 mm for glass or bones. Usually metal detectors are set at the end of the production line just before packaging but in some cases they can be included in the line in order to protect the next machine that intervenes to process the food. (A.C.)

  5. Design and safety consideration in the High-Temperature Engineering Test Reactor (HTTR)

    International Nuclear Information System (INIS)

    Saito, Shinzo; Tanaka, Toshiuki; Sudo, Yukio; Baba, Osamu; Shiozawa, Shusaku; Okubo, Minoru

    1990-01-01

    The budget for construction of the High-Temperature Engineering Test Reactor (HTTR) was recently committed by the Government in Japan. The HTTR is a test reactor with thermal output of 30 MW and reactor outlet coolant temperature of 950 deg. C at high temperature test operation. The HTTR plant uses a pin-in-block design core and will be used as an experience leading to high temperature applications. Several major important safety considerations are adopted in the design of the HTTR. These are as follows: 1) A coated particle fuel must not be failed during a normal reactor operation and an anticipated operational occurrence; 2) Two independent and diverse reactor shut-down systems are provided in order to shut down the reactor safely and reliably in any condition; 3) Back-up reactor cooling systems which are safety ones are provided in order to remove residual heat of reactor in any condition; 4) Multiple barriers and countermeasures are provided to contain fission products such as a containment, pressure gradient between the primary and secondary cooling circuit and so on, though coated particle fuels contain fission products with high reliability; 5) The functions of materials used in the primary cooling circuit are separated to be pressure-resisting and heat-resisting in order to resolve material problems and maintain high reliability. The detailed design of the HTTR was completed with extensive accumulation of material data and component tests. (author)

  6. An Overview of Trials´Accreditation and Recognition of Brazilian Tests Used for the Safety Evaluation of Cosmetic Products

    Directory of Open Access Journals (Sweden)

    Luciana dos Santos Almeida

    2016-06-01

    Full Text Available For some time, Brazil has been appointed as one of the greatest consumers of cosmetic products in the world. Although cosmetics may seem harmless, destined exclusively to enhance personal appearance or to clean and protect the skin, hair and nails, new studies and events are highlighting the need to evaluate the safety of such products. The present work interrelated the lifecycle of a cosmetic product with the safety trials and tests applicable to some cycle phases. From this information, a survey was made of accredited Conformity Assessment Bodies (CAB and test facilities recognized by the General Coordination for Accreditation (CGCRE which are competent respectively to carry out safety trials and tests of cosmetics. Twenty five competent laboratories were identified to carry out chemical and/or biological trials of cosmetics, according to the legislation ABNT ISO IEC 17025:2005, and 10 test facilities recognized by the Compliance Monitoring Program that can carry out tests of the development of a product for register purposes, aiming at human health and safety. It is interesting to notice that Brazil has accredited laboratories to carry out trials that are critical for the health of the population, such as the levels of heavy metals and the presence of pathogens. On the other hand, CGCRE does not have a program to recognize safety clinical trials. The importance of this kind of study is understood, considering the world history of adverse reactions and the great consumption of cosmetics in the country.

  7. The roles of EBR-II and TREAT [Transient Reactor Test] in establishing liquid metal reactor safety

    International Nuclear Information System (INIS)

    Sackett, J.I.; Lehto, W.K.; Solbrig, C.W.

    1990-01-01

    This paper examines the role of the Experimental Breeder Reactor II (EBR-II) and Transient Reactor Test (TREAT) facilities in contributing to the understanding and resolution of key safety issues in liquid metal reactor safety during the decade of the 80's. Fuels and materials testing has been carried out to address questions on fuels behavior during steady-state and upset conditions. In addition, EBR-II has conducted plant tests to demonstrate passive response to ATWS events and to develop control and diagnostic strategies for safe operation of advanced LMRs. TREAT and EBR-II complement each other and between them provide a transient testing capability that covers the whole range of concerns during overpower conditions. EBR-II, with use of the special Automatic Control Rod Drive System, can generate power change rates that overlap the lower end of the TREAT capability. 21 refs

  8. Safety analysis of the 700-horsepower combustion test facility

    Energy Technology Data Exchange (ETDEWEB)

    Berkey, B.D.

    1981-05-01

    The objective of the program reported herein was to provide a Safety Analysis of the 700 h.p. Combustion Test Facility located in Building 93 at the Pittsburgh Energy Technology Center. Extensive safety related measures have been incorporated into the design, construction, and operation of the Combustion Test Facility. These include: nitrogen addition to the coal storage bin, slurry hopper, roller mill and pulverizer baghouse, use of low oxygen content combustion gas for coal conveying, an oxygen analyzer for the combustion gas, insulation on hot surfaces, proper classification of electrical equipment, process monitoring instrumentation and a planned remote television monitoring system. Analysis of the system considering these factors has resulted in the determination of overall probabilities of occurrence of hazards as shown in Table I. Implementation of the recommendations in this report will reduce these probabilities as indicated. The identified hazards include coal dust ignition by hot ductwork and equipment, loss of inerting within the coal conveying system leading to a coal dust fire, and ignition of hydrocarbon vapors or spilled oil, or slurry. The possibility of self-heating of coal was investigated. Implementation of the recommendations in this report will reduce the ignition probability to no more than 1 x 10/sup -6/ per event. In addition to fire and explosion hazards, there are potential exposures to materials which have been identified as hazardous to personal health, such as carbon monoxide, coal dust, hydrocarbon vapors, and oxygen deficient atmosphere, but past monitoring experience has not revealed any problem areas. The major environmental hazard is an oil spill. The facility has a comprehensive spill control plan.

  9. Vibration analysis of the Golfech 2 safety injection system

    International Nuclear Information System (INIS)

    Morilhat, P.

    1993-01-01

    The main function of the safety injection system in a PWR plant is to ensure cooling of fuel elements in the event of a loss of coolant accident. The multistage centrifugal pump mounted-on this system induces pressure fluctuations, resulting in dynamic loads on piping. In certain plant units, these loads have caused cracking in the nozzles connected to the safety injection system, whereas in others, no damage has been observed. In order to understand the differences in dynamic behavior observed from one site to another, tests were performed on a real safety injection system, that of Golfech-2. They enabled determination of the modal characteristics of the system and identification of the hydro-acoustic source of the low head safety injection pump. They also enabled assessment of the pressure fluctuation levels in the pump suction and discharge areas as well as the vibratory response of the system when operating under partial and nominal flow conditions. Finally, these test results were used to estimate fatigue damage in the safety injection system. The experimental results will later be used to validate the model of the system undertaken with the piping design code CIRCUS and define the boundary conditions to be taken into account. (author). 6 figs., 2 refs

  10. Safety tests of bobbin-type lithium-thionyl chloride D-cells

    Energy Technology Data Exchange (ETDEWEB)

    Okamura, Yasuyuki; Mizutani, Minoru

    1987-12-25

    Safety test was made focusing on the possibilities of explosion and leakage of bobbin-type lithium-thionyl chloride D-cells. The result indicates that there is no abnormality including explosion even at the vigorous testing including the large current charging test. Meanwhile, since the instability of battery at large current became clear, it was reconfirmed that a protective element against charging would be required. A lost of irritating, toxic, corrosive electrolyte leaking from crushed and drilled batteries is apt to injure the human respiratory organs in a closed space. It is necessary to surely implement the protective measure against abnormal temperature increase by using the battery with care taken not to throw it into flame, keep it away from a heat source as well as charge it. In addition, the protective element against charging such as charging protection diode and the protection against the destruction by external force are required. (12 figs, 2 tabs, 3 refs)

  11. Safety of type and screen method compared to conventional antiglobulin crossmatch procedures for compatibility testing in Indian setting

    Directory of Open Access Journals (Sweden)

    Chaudhary Rajendra

    2011-01-01

    Full Text Available Background: Over the past 30 years, pretransfusion tests have undergone considerable modification. In 1984, AABB recommended that the full cross match could be replaced by an abbreviated cross match in patients with negative antibody screen. However, before implementation of such a policy, issue regarding safety of T & S needs to be evaluated. Objectives: The aim of pretransfusion testing (PTT is to ensure that enough red blood cells (RBCs in the selected red cell components will survive when transfused. Results and Conclusion: We have, therefore in this study; evaluated safety of T & S procedure for PTT in comparison with conventional test tube cross match. The T & S procedure gave a safety of 91.6%. Also, the usefulness of the T & S was shown through the detection of unexpected antibodies in 0.75% (15 out of 2026 of cases.

  12. LOFT integral test system final safety analysis report

    International Nuclear Information System (INIS)

    1974-03-01

    Safety analyses are presented for the following LOFT Reactor systems: engineering safety features; support buildings and facilities; instrumentation and controls; electrical systems; and auxiliary systems. (JWR)

  13. Performance and Safety Tests on Samsung 18650 Li-ion Cells with Two Capacities

    Science.gov (United States)

    Deng, Yi; Jeevarajan, Judith; Rehm, Raymond; Bragg, Bobby; Zhang, Wenlin

    2001-01-01

    In order to meet the applications for Space Shuttle in the future, Samsung 18650 cylindrical Li-ion cells with two different capacities have been evaluated. The capacities are 1800 mAh, and 2000 mAh. The studies focused on the performance and safety tests of the cells.

  14. Analysis using formal method and testing technique for the processor module for safety-critical application

    International Nuclear Information System (INIS)

    Choi, J. Y.; Choi, B. J.; Song, H. J.; Hwang, D. Y.; Song, G. H.; Lee, H.

    2008-06-01

    This research is on help develop nuclear power plant control system, through the requirement specification and verification method development. As the result of applying the test method, a test standard was obtain through test documentation writing support and a test document reflecting the standard test activities based on the test standard. The specification and verification of the pCOS system and the unified testing documentation and execution helps the entire project to progress and enable us to achieve necessary documents and technology to develop a safety critical system

  15. Analysis using formal method and testing technique for the processor module for safety-critical application

    Energy Technology Data Exchange (ETDEWEB)

    Choi, J. Y.; Choi, B. J.; Song, H. J.; Hwang, D. Y.; Song, G. H.; Lee, H. [Korea University, Seoul (Korea, Republic of)

    2008-06-15

    This research is on help develop nuclear power plant control system, through the requirement specification and verification method development. As the result of applying the test method, a test standard was obtain through test documentation writing support and a test document reflecting the standard test activities based on the test standard. The specification and verification of the pCOS system and the unified testing documentation and execution helps the entire project to progress and enable us to achieve necessary documents and technology to develop a safety critical system.

  16. Thermal Hydraulic Tests for Reactor Core Safety

    Energy Technology Data Exchange (ETDEWEB)

    Moon, S. K.; Baek, W. P.; Chun, S. Y. (and others)

    2007-06-15

    The main objectives of the present project are to resolve the current issues of reactor core thermal hydraulics, to develop an advanced measurement and analytical techniques, and to perform reactor core safety verification tests. 6x6 reflood experiments, various heat transfer experiments using Freon, and experiments on the spacer grids effects on the post-dryout are carried out using spacer grids developed in Korea in order to resolve the current issues of the reactor core thermal hydraulics. In order to develop a reflood heat transfer model, the detailed reflood phenomena are visualized and measured using round tube and 2x2 rod bundle. A detailed turbulent mixing phenomenon for subchannels is measured using advanced measurement techniques such as LDV and PIV. MARS and MATRA codes developed in Korea are assessed, verified and improved using the obtained experimental data. Finally, a systematic quality assurance program and experimental data generation system has been constructed in order to increase the reliability of the experimental data.

  17. Safety assessment of botanicals and botanical preparations used as ingredients in food supplements: Testing an EFS tired approach

    NARCIS (Netherlands)

    Speijers, G.; Bottex, B.; Dusemund, B.; Lugasi, A.; Toth, J.; Amberg-Muller, J.; Galli, C.; Silano, V.; Rietjens, I.

    2010-01-01

    This article describes results obtained by testing the European Food Safety Authority-tiered guidance approach for safety assessment of botanicals and botanical preparations intended for use in food supplements. Main conclusions emerging are as follows. (i) Botanical ingredients must be identified

  18. Progress in design, research and development and testing of safety systems for advanced water cooled reactors. Proceedings of a technical committee meeting

    International Nuclear Information System (INIS)

    1996-04-01

    The meeting covered the following topics: Developments in design of safety-related heat removal components and systems for advanced water cooled reactors; status of test programmes on heat removal components and systems of new designs; range of validity and extrapolation of test results for the qualification of design/licensing computer models and codes for advanced water cooled reactors; future needs and trends in testing of safety systems for advanced water cooled reactors. Tests of heat removal safety systems have been conducted by various groups supporting the design, testing and certification of advanced water cooled reactors. The Technical Committee concluded that the reported test results generally confirm the predicted performance features of the advanced designs. Refs, figs, tabs

  19. Progress in design, research and development and testing of safety systems for advanced water cooled reactors. Proceedings of a technical committee meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    The meeting covered the following topics: Developments in design of safety-related heat removal components and systems for advanced water cooled reactors; status of test programmes on heat removal components and systems of new designs; range of validity and extrapolation of test results for the qualification of design/licensing computer models and codes for advanced water cooled reactors; future needs and trends in testing of safety systems for advanced water cooled reactors. Tests of heat removal safety systems have been conducted by various groups supporting the design, testing and certification of advanced water cooled reactors. The Technical Committee concluded that the reported test results generally confirm the predicted performance features of the advanced designs. Refs, figs, tabs.

  20. Reactor safety impact of functional test intervals: an application of Bayesian decision theory

    International Nuclear Information System (INIS)

    Buoni, F.B.

    1978-01-01

    Functional test intervals for important nuclear reactor systems can be obtained by viewing safety assessment as a decision process and functional testing as a Bayesian learning or information process. A preposterior analysis is used as the analytical model to find the preposterior expected reliability of a system as a function of test intervals. Persistent and transitory failure models are shown to yield different results. Functional tests of systems subject to persistent failure are effective in maintaining system reliability goals. Functional testing is not effective for systems subject to transitory failure; preventive maintenance must be used. A Bayesian posterior analysis of testing data can discriminate between persistent and transitory failure. The role of functional testing is seen to be an aid in assessing the future performance of reactor systems

  1. Environmental testing of a prototypic digital safety channel, phase I: System design and test methodology

    International Nuclear Information System (INIS)

    Korsah, K.; Turner, G.W.; Mullens, J.A.

    1995-01-01

    A microprocessor-based reactor trip channel has been assembled for environmental testing under an Instrumentation and Control (I ampersand C) Qualification Program sponsored by the U.S. Nuclear Regulatory Commission. The goal of this program is to establish the technical basis for the qualification of advanced I ampersand C systems. The trip channel implemented for this study employs technologies and digital subsystems representative of those proposed for use in some advanced light-water reactors (ALNWS) such as the Simplified Boiling Water Reactor (SBNW) and AP600. It is expected that these tests will reveal any potential system vulnerabilities for technologies representative of those proposed for use in ALNWS. The experimental channel will be purposely stressed considerably beyond what it is likely to experience in a normal nuclear power plant environment, so that the tests can uncover the worst-case failure modes (i.e., failures that are likely to prevent an entire trip system from performing its safety function when required to do so). Based on information obtained from this study, it may be possible to recommend tests that are likely to indicate the presence of such failure mechanisms. Such recommendations would be helpful in augmenting current qualification guidelines

  2. Environmental testing of a prototypic digital safety channel, Phase I: System design and test methodology

    Energy Technology Data Exchange (ETDEWEB)

    Korsah, K.; Turner, G.W.; Mullens, J.A. [Oak Ridge National Lab., TN (United States)

    1995-04-01

    A microprocessor-based reactor trip channel has been assembled for environmental testing under an Instrumentation and Control (I&C) Qualification Program sponsored by the US Nuclear Regulatory Commission. The goal of this program is to establish the technical basis and acceptance criteria for the qualification of advanced I&C systems. The trip channel implemented for this study employs technologies and digital subsystems representative of those proposed for use in some advanced light-water reactors (ALWRs) such as the Simplified Boiling Water Reactor (SBWR). It is expected that these tests will reveal any potential system vulnerabilities for technologies representative of those proposed for use in ALWRs. The experimental channel will be purposely stressed considerably beyond what it is likely to experience in a normal nuclear power plant environment, so that the tests can uncover the worst-case failure modes (i.e., failures that are likely to prevent an entire trip system from performing its safety function when required to do so). Based on information obtained from this study, it may be possible to recommend tests that are likely to indicate the presence of such failure mechanisms. Such recommendations would be helpful in augmenting current qualification guidelines.

  3. JRR-3 cold neutron source facility H2-O2 explosion safety proof testing

    International Nuclear Information System (INIS)

    Hibi, T.; Fuse, H.; Takahashi, H.; Akutsu, C.; Kumai, T.; Kawabata, Y.

    1990-01-01

    A cold Neutron Source (CNS) will be installed in Japan Research Reactor-3 (JRR-3) in Japan Atomic Energy Research Institute (JAERI) during its remodeling project. This CNS holds liquid hydrogen at a temperature of about 20 K as a cold neutron source moderator in the heavy water area of the reactor to moderate thermal neutrons from the reactor to cold neutrons of about 5 meV energy. In the hydrogen circuit of the CNS safety measures are taken to prevent oxygen/hydrogen reaction (H 2 -O 2 explosion). It is also designed in such manner that, should an H 2 -O 2 explosion take place, the soundness of all the components can be maintained so as not to harm the reactor safety. A test hydrogen circuit identical to that of the CNS (real components designed by TECHNICATOME of France) was manufactured to conduct the H 2 -O 2 explosion test. In this test, the detonation that is the severest phenomenon of the oxygen/hydrogen reaction took place in the test hydrogen circuit to measure the exerted pressure on the components and their strain, deformation, leakage, cracking, etc. Based on the results of this measurement, the structural strength of the test hydrogen circuit was analyzed. The results of this test show that the hydrogen circuit components have sufficient structural strength to withstand an oxygen/hydrogen reaction

  4. Time dependent unavailability analysis of nuclear safety systems considering periodically tested components

    International Nuclear Information System (INIS)

    Goes, Alexandre Gromann de Araujo

    1988-01-01

    It is of utmost importance to have a computer code in order to analyze how different parameters (like test duration time) affect the unavailability of safety systems of nuclear. In this context, a study was performed in order to evaluate the model employed by the FRANTIC computer code, which performs detailed calculations on the contribution to the system unavailability originated by hardware failures, component tests and repairs, aiming at considering the influence of different test schemes on the system unavailability. It was shown, by means of the results attained that the numerical model used by the FRANTIC code and the analytical model proposed by APOSTOLAKIS and CHU (4) give unavailability values much similar when the component tests are supposed to be perfect. When a test is supposed to be imperfect (that is, when it may induce a test is supposed to be imperfect (that is, when it may induce a failure on the component being tested), the analytical model presents more conservative results. (author)

  5. Integrated vehicle-based safety systems light-vehicle field operational test, methodology and results report.

    Science.gov (United States)

    2010-12-01

    "This document presents the methodology and results from the light-vehicle field operational test conducted as part of the Integrated Vehicle-Based Safety Systems program. These findings are the result of analyses performed by the University of Michi...

  6. Assuring safety without animal testing concept (ASAT). Integration of human disease data with in vitro data to improve toxicology testing

    NARCIS (Netherlands)

    Stierum, Rob; Aarts, Jac; Boorsma, Andre; Bosgra, Sieto; Caiment, Florian; Ezendam, Janine; Greupink, Rick; Hendriksen, Peter; Soeteman-Hernandez, Lya G.; Jennen, Danyel; Kleinjans, Jos; Kroese, Dinant; Kuper, Frieke; van Loveren, Henk; Monshouwer, Mario; Russel, Frans; van Someren, Eugene; Tsamou, Maria; Groothuis, Geny

    2014-01-01

    According to the Assuring Safety Without Animal Testing (ASAT) principle, risk assessment may ultimately become possible without the use of animals (Fentem et al., (2004). Altern. Lab. Anim. 32, 617-623). The ASAT concept takes human disease mechanisms as starting point and tries to define if

  7. Patient-led training on patient safety: a pilot study to test the feasibility and acceptability of an educational intervention.

    Science.gov (United States)

    Jha, V; Winterbottom, A; Symons, J; Thompson, Z; Quinton, N; Corrado, O J; Melville, C; Watt, I; Torgerson, D; Wright, J

    2013-09-01

    Training in patient safety is an important element of medical education. Most educational interventions on patient safety training adopt a 'health-professional lens' with limited consideration on the impact of safety lapses on the patient and their families and little or no involvement of patients in the design or delivery of the training. This paper describes a pilot study to test the feasibility and acceptability of implementing a patient-led educational intervention to facilitate safety training amongst newly qualified doctors. Patients and/or carers who had experienced harm during their care shared narratives of their stories with trainees; this was followed by a focused discussion on patient safety issues exploring the causes and consequences of safety incidents and lessons to be learned from these. The intervention, which will be further tested in an NIHR-funded randomised controlled trial (RCT), was successfully implemented into an existing training programme and found acceptance amongst the patients and trainees. The pilot study proved to be a useful step in refining the intervention for the RCT including identifying appropriate outcome measures and highlighting organisational issues.

  8. Safety demonstration test (SR-3/S1C-3/S2C-3/SF-2) plan using the HTTR. Contract research

    International Nuclear Information System (INIS)

    Nakagawa, Shigeaki; Sakaba, Nariaki; Takamatsu, Kuniyoshi; Takada, Eiji; Tochio, Daisuke; Ohwada, Hiroyuki

    2005-03-01

    Safety demonstration tests using the HTTR are to be conducted from the FY2002 to verify the inherent safety features and to improve the safety design and evaluation technologies for HTGRs, as well as to contribute to not only the commercial HTGRs but also the research and development for the VHTR that is one of the Generation IV reactor candidates. This paper describes the reactivity insertion test (SR-3), the coolant flow reduction test by tripping of gas circulators (S1C-3, S2C-3), and the partial flow loss of coolant test (SF-2) planned in March 2005 with their detailed test method, procedure and results of pre-test analysis. From the analytical results, it was verified that the negative reactivity feedback effect of the core brings the reactor power safely to a stable level without a reactor scram. (author)

  9. US Department of Energy DOE Nevada Operations Office, Nevada Test Site: Underground safety and health standards

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The Nevada Test Site Underground Safety and Health Standards Working Group was formed at the direction of John D. Stewart, Director, Nevada Test Site Office in April, 1990. The objective of the Working Group was to compile a safety and health standard from the California Tunnel Safety Orders and OSHA for the underground operations at the NTS, (excluding Yucca Mountain). These standards are called the NTS U/G Safety and Health Standards. The Working Group submits these standards as a RECOMMENDATION to the Director, NTSO. Although the Working Group considers these standards to be the most integrated and comprehensive standards that could be developed for NTS Underground Operations, the intent is not to supersede or replace any relevant DOE orders. Rather the intent is to collate the multiple safety and health references contained in DOE Order 5480.4 that have applicability to NTS Underground Operations into a single safety and heath standard to be used in the underground operations at the NTS. Each portion of the standard was included only after careful consideration by the Working Group and is judged to be both effective and appropriate. The specific methods and rationale used by the Working Group are outlined as follows: The letter from DOE/HQ, dated September 28, 1990 cited OSHA and the CTSO as the safety and health codes applicable to underground operations at the NTS. These mandated codes were each originally developed to be comprehensive, i.e., all underground operations of a particular type (e.g., tunnels in the case of the CTSO) were intended to be adequately regulated by the appropriate code. However, this is not true; the Working Group found extensive and confusing overlap in the codes in numerous areas. Other subjects and activities were addressed by the various codes in cursory fashion or not at all.

  10. US Department of Energy DOE Nevada Operations Office, Nevada Test Site: Underground safety and health standards

    International Nuclear Information System (INIS)

    1993-05-01

    The Nevada Test Site Underground Safety and Health Standards Working Group was formed at the direction of John D. Stewart, Director, Nevada Test Site Office in April, 1990. The objective of the Working Group was to compile a safety and health standard from the California Tunnel Safety Orders and OSHA for the underground operations at the NTS, (excluding Yucca Mountain). These standards are called the NTS U/G Safety and Health Standards. The Working Group submits these standards as a RECOMMENDATION to the Director, NTSO. Although the Working Group considers these standards to be the most integrated and comprehensive standards that could be developed for NTS Underground Operations, the intent is not to supersede or replace any relevant DOE orders. Rather the intent is to collate the multiple safety and health references contained in DOE Order 5480.4 that have applicability to NTS Underground Operations into a single safety and heath standard to be used in the underground operations at the NTS. Each portion of the standard was included only after careful consideration by the Working Group and is judged to be both effective and appropriate. The specific methods and rationale used by the Working Group are outlined as follows: The letter from DOE/HQ, dated September 28, 1990 cited OSHA and the CTSO as the safety and health codes applicable to underground operations at the NTS. These mandated codes were each originally developed to be comprehensive, i.e., all underground operations of a particular type (e.g., tunnels in the case of the CTSO) were intended to be adequately regulated by the appropriate code. However, this is not true; the Working Group found extensive and confusing overlap in the codes in numerous areas. Other subjects and activities were addressed by the various codes in cursory fashion or not at all

  11. The Development of Computer Code for Safety Injection Tank (SIT) with Fluidic Device(FD) Blowdown Test

    International Nuclear Information System (INIS)

    Lee, Joo Hee; Kim, Tae Han; Choi, Hae Yun; Lee, Kwang Won; Chung, Chang Kyu

    2007-01-01

    Safety Injection Tanks (SITs) with the Fluidic Device (FD) of APR1400 provides a means of rapid reflooding of the core following a large break Loss Of Coolant Accident (LOCA), and keeping it covered until flow from the Safety Injection Pump (SIP) becomes available. A passive FD can provide two operation stages of a safety water injection into the RCS and allow more effective use of borated water in case of LOCA. Once a large break LOCA occurs, the system will deliver a high flow rate of cooling water for a certain period of time, and thereafter, the flow rate is reduced to a lower flow rate. The conventional computer code 'TURTLE' used to simulate the blowdown of OPR1000 SIT can not be directly applied to simulate a blowdown process of the SIT with FD. A new computer code is needed to be developed for the blowdown test evaluation of the APR1400 SIT with FD. Korea Power Engineering Company (KOPEC) has developed a new computer code to analyze the characteristics of the SIT with FD and validated the code through the comparison of the calculation results with the test results obtained by Ulchin 5 and 6 units pre-operational test and VAlve Performance Evaluation Rig (VAPER) tests performed by The Korea Atomic Energy Research Institute (KAERI)

  12. In-pile irradiation test program and safety analysis report of the KAERI fuel for HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Wan; Ryu, Woo Suck; Byun, Taek Sang; Park, Jong Man; Lee, Byung Chul; Kim, Hack No; Park, Hee Tae; Kim, Chang Kyu [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-05-01

    Localization of HANARO fuel has been carried out successfully, and design and fabrication technologies of the fuel are recently arrived the final stage of development. The performance of the fuel which has been fabricated in KAERI is confirmed through out-of-pile characterization, and the quality assurance procedure and assessment criteria are described. In order to verify the KAERI fuel, thus, in-pile irradiation test program of the KAERI fuel is scheduled in HANARO. This report summarizes the in-pile testing schedule, design documents of test rods and assemblies, fabrication history and out-of-pile characteristics of test rods, irradiation test condition and power history, post-irradiation examination scheme, linear power generation distribution, and safety analysis results. The design code for HANARO fuel is used to analyze the centerline temperature and swelling of the KAERI fuels. The results show that at 120 kW/m of linear power the maximum centerline temperature is 267 deg C which is much lower than the limitation temperature of 350 deg C, and that the swelling is 9.3 % at 95 at% lower than criterion of 20 %. Therefore, the KAERI fuels of this in-pile irradiation test is assessed to show good performance of integrity and safety in HANARO. 10 tabs., 7 figs., 3 refs. (Author).

  13. A Proposal for a Methodology to Develop a Cyber-Attack Penetration Test Scenario Including NPPs Safety

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Hyo [KAIST, Daejeon (Korea, Republic of); Son, Han Seong [Joongbu Univ., Geumsan (Korea, Republic of); Kim, Si Won [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of); Kang, Hyun Gook [Rensselaer Polytechnic Institute, Troy (United States)

    2016-10-15

    Penetration test is a method to evaluate the cyber security of NPPs; so, this approach was performed in some studies. Because they focused on vulnerability finding or test bed construction, scenario based approach was not performed. However, to test the cyber security of NPPs, a proper test scenario should be needed. Ahn et al. developed cyber-attack scenarios but those scenarios couldn't be applied in penetration test because they developed the scenarios based on past incidents of NPPs induced by cyber-attack. That is, those scenarios only covered scenarios which were happened before; so, they couldn't cover other various scenarios and couldn't reflect them into a penetration test. In this study, a method to develop a cyber-attack penetration test scenario of NPPs especially focused on safety point of view is suggested. To evaluate the cyber security of NPPs, penetration test can be a possible way. In this study, a method to develop a penetration test scenario was explained. Especially, the goal of hacker was focused on nuclear fuel integrity deterioration. So, in the methodology, Level 1 PSA results were utilized to reflect plant safety into the security. From the PSA results, basic event was post processed and possible cyber-attacks were reviewed with vulnerabilities of digital control system.

  14. A Proposal for a Methodology to Develop a Cyber-Attack Penetration Test Scenario Including NPPs Safety

    International Nuclear Information System (INIS)

    Lee, In Hyo; Son, Han Seong; Kim, Si Won; Kang, Hyun Gook

    2016-01-01

    Penetration test is a method to evaluate the cyber security of NPPs; so, this approach was performed in some studies. Because they focused on vulnerability finding or test bed construction, scenario based approach was not performed. However, to test the cyber security of NPPs, a proper test scenario should be needed. Ahn et al. developed cyber-attack scenarios but those scenarios couldn't be applied in penetration test because they developed the scenarios based on past incidents of NPPs induced by cyber-attack. That is, those scenarios only covered scenarios which were happened before; so, they couldn't cover other various scenarios and couldn't reflect them into a penetration test. In this study, a method to develop a cyber-attack penetration test scenario of NPPs especially focused on safety point of view is suggested. To evaluate the cyber security of NPPs, penetration test can be a possible way. In this study, a method to develop a penetration test scenario was explained. Especially, the goal of hacker was focused on nuclear fuel integrity deterioration. So, in the methodology, Level 1 PSA results were utilized to reflect plant safety into the security. From the PSA results, basic event was post processed and possible cyber-attacks were reviewed with vulnerabilities of digital control system

  15. Nonminimal hints for asymptotic safety

    Science.gov (United States)

    Eichhorn, Astrid; Lippoldt, Stefan; Skrinjar, Vedran

    2018-01-01

    In the asymptotic-safety scenario for gravity, nonzero interactions are present in the ultraviolet. This property should also percolate into the matter sector. Symmetry-based arguments suggest that nonminimal derivative interactions of scalars with curvature tensors should therefore be present in the ultraviolet regime. We perform a nonminimal test of the viability of the asymptotic-safety scenario by working in a truncation of the renormalization group flow, where we discover the existence of an interacting fixed point for a corresponding nonminimal coupling. The back-coupling of such nonminimal interactions could in turn destroy the asymptotically safe fixed point in the gravity sector. As a key finding, we observe nontrivial indications of stability of the fixed-point properties under the impact of nonminimal derivative interactions, further strengthening the case for asymptotic safety in gravity-matter systems.

  16. Transition towards replacing animal tests in safety assessment of cosmetics and chemicals: a combined TIS-MLP framework

    NARCIS (Netherlands)

    Kooijman, M.; Meer, P. van de; Moors, E.H.M.; Schellekens, H.; Hekkert, M.P.

    2012-01-01

    The urgency of the transition to replace animal tests in safety assessment of chemicals and cosmetics was triggered by societal resistance to animal testing (Rowan, 2007) and the scientific dispute concerning the value of animal testing (Olson et al., 2000). Since the 1980s the European Union (EU)

  17. Validation of programmable industrial automation systems for safety critical applications in NPP's; dynamic testing

    International Nuclear Information System (INIS)

    Haapanen, P.; Korhonen, J.

    1995-01-01

    The safety assessment of programmable automation systems cannot be totally be based on conventional probabilistic methods because of the difficulties in quantification of the reliability of the software as well as the hardware. Additional means shall therefore be used to gain more confidence on the system dependability. One central confidence building measure is the independent dynamic testing of the completed system. An automated test harness is needed to run the required large amount of test cases in a restricted time span. This paper describes a prototype dynamic testing harness for programmable digital systems developed at VTT. (author). 12 refs, 2 figs, 2 tabs

  18. Studies to demonstrate the adequacy of testing results of the qualification tests for the actuator of main steam safety relive valves (MSSRV) in an advanced boiling water reactor (ABWR)

    International Nuclear Information System (INIS)

    Gou, P.F.; Patel, R.; Curran, G.; Henrie, D.; Solorzano, E.

    2005-01-01

    This paper presents several studies performed to demonstrate that the testing results from the qualification tests for the actuator of the Main Steam Safety Relief Valves (MSSRV; also called SRV in this paper) in GE's Advanced Boiling Water Reactor (ABWR) are in compliance with the qualification guidelines stipulated in the applicable IEEE standards. The safety-related function of the MSSRV is to relieve pressure in order to protect the reactor pressure vessel from over-pressurization condition during normal operation and design basis events. In order to perform this function, the SRV must actuate at a given set pressure while maintaining the pressure and structural integrity of the SRV. The valves are provided with an electro-pneumatic actuator assembly that opens the valve upon receipt of an automatic or manually initiated electric signal to allow depressurization of the reactor pressure vessel (RPV). To assure the SRV can perform its intended safety related functions properly, qualification tests are needed in addition to analysis, to demonstrate that the SRV can withstand the specified environmental, dynamic and seismic design basis conditions without impairing its safety related function throughout their installed life under the design conditions including postulated design basis events such as OBE loads and Faulted (SSE) events. The guidelines used for the test methods, procedures and acceptance criteria for the qualification tests are established in IEEE std 344-1987 and IEEE std 382-1985. In the qualification tests, the specimen consists of the actuator, control valve assembly, limit switches, and limit switch support structure. During the functional, dynamic and seismic tests, the test specimen was mounted on a SRV. Qualification of safety related equipment to meet the guidelines of the IEEE standards is typically a two-step process: 1) environmental aging and 2) design basis events qualification. The purpose of the first step is to put the equipment in an

  19. Muscle Force-Velocity Relationships Observed in Four Different Functional Tests.

    Science.gov (United States)

    Zivkovic, Milena Z; Djuric, Sasa; Cuk, Ivan; Suzovic, Dejan; Jaric, Slobodan

    2017-02-01

    The aims of the present study were to investigate the shape and strength of the force-velocity relationships observed in different functional movement tests and explore the parameters depicting force, velocity and power producing capacities of the tested muscles. Twelve subjects were tested on maximum performance in vertical jumps, cycling, bench press throws, and bench pulls performed against different loads. Thereafter, both the averaged and maximum force and velocity variables recorded from individual trials were used for force-velocity relationship modeling. The observed individual force-velocity relationships were exceptionally strong (median correlation coefficients ranged from r = 0.930 to r = 0.995) and approximately linear independently of the test and variable type. Most of the relationship parameters observed from the averaged and maximum force and velocity variable types were strongly related in all tests (r = 0.789-0.991), except for those in vertical jumps (r = 0.485-0.930). However, the generalizability of the force-velocity relationship parameters depicting maximum force, velocity and power of the tested muscles across different tests was inconsistent and on average moderate. We concluded that the linear force-velocity relationship model based on either maximum or averaged force-velocity data could provide the outcomes depicting force, velocity and power generating capacity of the tested muscles, although such outcomes can only be partially generalized across different muscles.

  20. Building America Case Study: Combustion Safety Simplified Test Protocol, Chicago Illinois, and Minneapolis, Minnesota

    Energy Technology Data Exchange (ETDEWEB)

    2015-12-01

    "9Combustion safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

  1. Development and Testing of a Nutrition, Food Safety, and Physical Activity Checklist for EFNEP and FSNE Adult Programs

    Science.gov (United States)

    Bradford, Traliece; Serrano, Elena L.; Cox, Ruby H.; Lambur, Michael

    2010-01-01

    Objective: To develop and assess reliability and validity of the Nutrition, Food Safety, and Physical Activity Checklist to measure nutrition, food safety, and physical activity practices among adult Expanded Food and Nutrition Education Program (EFNEP) and Food Stamp Nutrition Education program (FSNE) participants. Methods: Test-retest…

  2. Tests on instrumentation and control systems important to safety in nuclear power stations. Systempruefung der leittechnischen Einrichtungen des Sicherheitssystems in Kernkraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    The rule applies to the reactor protection system, to the protection and state boundaries, to control devices important to safety, and to danger alarms of the classes S and I. The system inspection of the control devices of the safety system comprises in-service testing and recurrent testing.

  3. Safety Design Strategy for the Advanced Test Reactor Diesel Bus (E-3) and Switchgear Replacement Project

    International Nuclear Information System (INIS)

    Duckwitz, Noel

    2011-01-01

    In accordance with the requirements of U.S. Department of Energy (DOE) Order 413.3B, 'Program and Project Management for the Acquisition of Capital Assets,' safety must be integrated into the design process for new or major modifications to DOE Hazard Category 1, 2, and 3 nuclear facilities. The intended purpose of this requirement involves the handling of hazardous materials, both radiological and chemical, in a way that provides adequate protection to the public, workers, and the environment. Requirements provided in DOE Order 413.3B and DOE Order 420.1B, 'Facility Safety,' and the expectations of DOE-STD-1189-2008, 'Integration of Safety into the Design Process,' provide for identification of hazards early in the project and use of an integrated team approach to design safety into the facility. This safety design strategy provides the basic safety-in-design principles and concepts that will be used for the Advanced Test Reactor Reliability Sustainment Project. While this project does not introduce new hazards to the ATR, it has the potential for significant impacts to safety-related systems, structures, and components that are credited in the ATR safety basis and are being replaced. Thus the project has been determined to meet the definition of a major modification and is being managed accordingly.

  4. Additional safety assessments, follow-up of stress tests of the French nuclear power stations. Action plan of the nuclear safety authority

    International Nuclear Information System (INIS)

    2012-01-01

    This document presents the French national action plan defined by the Nuclear Safety Authority (ASN) in compliance with the recommendations made by the ENSREG (European nuclear safety regulators group). It refers to decisions taken at the national level after the Fukushima accident, recommendations after European stress tests, and recommendations after the extraordinary meeting of contracting parties at the Convention on Nuclear Safety of August 2012. For different topics, this document recalls the recommendations made by the peer review, indicates the ASN's opinion and progress or ASN's requirements for different power stations. The first part addresses the recommendations made by peers and based on the European review. Topics concern natural hazards (effects, detection, inspections and controls related to earthquakes, margin assessment with respect to flooding and natural hazards), the loss of safety systems (cooling systems, electricity supplies, actions, instruments, training, and so on), the management of a severe accident (reference levels, measures, guides, exercises, training, management of contaminated water, radiation protection, premises). The second part deals with topics addressed within the frame of the Convention: national organisations, organisations in an emergency and post-accidental situation, international cooperation. A third part addresses the follow-up of additional measures issued by the ASN

  5. A Delphi Technology Foresight Study: Mapping Social Construction of Scientific Evidence on Metagenomics Tests for Water Safety.

    Directory of Open Access Journals (Sweden)

    Stanislav Birko

    Full Text Available Access to clean water is a grand challenge in the 21st century. Water safety testing for pathogens currently depends on surrogate measures such as fecal indicator bacteria (e.g., E. coli. Metagenomics concerns high-throughput, culture-independent, unbiased shotgun sequencing of DNA from environmental samples that might transform water safety by detecting waterborne pathogens directly instead of their surrogates. Yet emerging innovations such as metagenomics are often fiercely contested. Innovations are subject to shaping/construction not only by technology but also social systems/values in which they are embedded, such as experts' attitudes towards new scientific evidence. We conducted a classic three-round Delphi survey, comprised of 107 questions. A multidisciplinary expert panel (n = 24 representing the continuum of discovery scientists and policymakers evaluated the emergence of metagenomics tests. To the best of our knowledge, we report here the first Delphi foresight study of experts' attitudes on (1 the top 10 priority evidentiary criteria for adoption of metagenomics tests for water safety, (2 the specific issues critical to governance of metagenomics innovation trajectory where there is consensus or dissensus among experts, (3 the anticipated time lapse from discovery to practice of metagenomics tests, and (4 the role and timing of public engagement in development of metagenomics tests. The ability of a test to distinguish between harmful and benign waterborne organisms, analytical/clinical sensitivity, and reproducibility were the top three evidentiary criteria for adoption of metagenomics. Experts agree that metagenomic testing will provide novel information but there is dissensus on whether metagenomics will replace the current water safety testing methods or impact the public health end points (e.g., reduction in boil water advisories. Interestingly, experts view the publics relevant in a "downstream capacity" for adoption of

  6. Improving patient safety during insertion of peripheral venous catheters: an observational intervention study

    Directory of Open Access Journals (Sweden)

    Kampf, Günter

    2013-11-01

    Full Text Available [english] Background: Peripheral venous catheters are frequently used in hospitalized patients but increase the risk of nosocomial bloodstream infection. Evidence-based guidelines describe specific steps that are known to reduce infection risk. However, the degree of guideline implementation in clinical practice is not known. The aim of this study was to determine the use of specific steps for insertion of peripheral venous catheters in clinical practice and to implement a multimodal intervention aimed at improving both compliance and the optimum order of the steps.Methods: The study was conducted at University Hospital Hamburg. An optimum procedure for inserting a peripheral venous catheter was defined based on three evidence-based guidelines (WHO, CDC, RKI including five steps with 1A or 1B level of evidence: hand disinfection before patient contact, skin antisepsis of the puncture site, no palpation of treated puncture site, hand disinfection before aseptic procedure, and sterile dressing on the puncture site. A research nurse observed and recorded procedures for peripheral venous catheter insertion for healthcare workers in four different departments (endoscopy, central emergency admissions, pediatrics, and dermatology. A multimodal intervention with 5 elements was established (teaching session, dummy training, e-learning tool, tablet and poster, and direct feedback, followed by a second observation period. During the last observation week, participants evaluated the intervention.Results: In the control period, 207 insertions were observed, and 202 in the intervention period. Compliance improved significantly for four of five steps (e.g., from 11.6% to 57.9% for hand disinfection before patient contact; p<0.001, chi-square test. Compliance with skin antisepsis of the puncture site was high before and after intervention (99.5% before and 99.0% after. Performance of specific steps in the correct order also improved (e.g., from 7.7% to 68

  7. Integrated vehicle-based safety systems (IVBSS) : light vehicle platform field operational test data analysis plan.

    Science.gov (United States)

    2009-12-22

    This document presents the University of Michigan Transportation Research Institutes plan to : perform analysis of data collected from the light vehicle platform field operational test of the : Integrated Vehicle-Based Safety Systems (IVBSS) progr...

  8. Integrated vehicle-based safety systems (IVBSS) : heavy truck platform field operational test data analysis plan.

    Science.gov (United States)

    2009-11-23

    This document presents the University of Michigan Transportation Research Institutes plan to perform : analysis of data collected from the heavy truck platform field operational test of the Integrated Vehicle- : Based Safety Systems (IVBSS) progra...

  9. Industrial safety in a nuclear decommissioning environment observations and lessons learned

    International Nuclear Information System (INIS)

    Brevig, D.

    2008-01-01

    Decommissioning activities present unusual and unexpected workplace safety challenges that go far beyond the traditional experience of nuclear power plant managers. A blend of state-of-the-art safety program management tools along with new and practical applications are required to ensure high industrial safety performance. The demanding and rigorously applied nuclear safety engineering standards that are accepted as normal and routine in the operation of a nuclear power facility, should transform as an industrial safety standard during the non-operating period of decommissioning. In addition, historical measures of non-nuclear industrial safety injury rates would or should not be acceptable safety behaviors during a nuclear decommissioning project. When complex projects, such as the decommissioning of a nuclear generating facility are undertaken, the workforce brings experience, qualifications, and assumptions to the project. The overall multi-year general schedule is developed, with more schedule details, for example, for the nearest rolling 12-18 months. Methods are established for the selection of contractors to assist in areas that are not normal tasks for the facility workforce, whose normal activity is managing and operating a nuclear generating station. However, it is critical to manage those contractors to the agreed work scope to ensure success is maintained by both parties, e.g. the job gets done, on schedule, on budget, all parties are financially whole when the work is complete, and safely. The purpose of this paper is to provide a perspective of nuclear plant personal safety in the ever changing industrial environment created by the demolition of robust and often radiologically contaminated structures in a nuclear facility decommissioning project. (author)

  10. Industrial safety in a nuclear decommissioning environment observations and lessons learned

    Energy Technology Data Exchange (ETDEWEB)

    Brevig, D. [Independent Consultant, San Clemente (United States)

    2008-07-01

    Decommissioning activities present unusual and unexpected workplace safety challenges that go far beyond the traditional experience of nuclear power plant managers. A blend of state-of-the-art safety program management tools along with new and practical applications are required to ensure high industrial safety performance. The demanding and rigorously applied nuclear safety engineering standards that are accepted as normal and routine in the operation of a nuclear power facility, should transform as an industrial safety standard during the non-operating period of decommissioning. In addition, historical measures of non-nuclear industrial safety injury rates would or should not be acceptable safety behaviors during a nuclear decommissioning project. When complex projects, such as the decommissioning of a nuclear generating facility are undertaken, the workforce brings experience, qualifications, and assumptions to the project. The overall multi-year general schedule is developed, with more schedule details, for example, for the nearest rolling 12-18 months. Methods are established for the selection of contractors to assist in areas that are not normal tasks for the facility workforce, whose normal activity is managing and operating a nuclear generating station. However, it is critical to manage those contractors to the agreed work scope to ensure success is maintained by both parties, e.g. the job gets done, on schedule, on budget, all parties are financially whole when the work is complete, and safely. The purpose of this paper is to provide a perspective of nuclear plant personal safety in the ever changing industrial environment created by the demolition of robust and often radiologically contaminated structures in a nuclear facility decommissioning project. (author)

  11. Nuclear Installation Safety: General Observations and Trends from IAEA Peer Reviews

    International Nuclear Information System (INIS)

    Rzentkowski, G.

    2016-01-01

    The Safety Review Services (SRSs) for nuclear installations address the needs of Member States at all stages of installations’ lifecycle. SRSs are based on the IAEA Safety Standards and are provided on Member States’ request to peer review national regulatory frameworks and safety provisions for nuclear installations. They result in recommendations and suggestions to improve national regulations and operational safety, and serve to exert peer pressure to ensure that that every Member State with nuclear installations recognizes its safety responsibility and the need to comply with the IAEA Safety Standards. This presentation provides an overview of SRSs for Nuclear Installations, including their structure and main subject areas. The presentation also summarizes general findings and trends which clearly demonstrate that there is continuous improvement in regulation of nuclear installations and in safety of their operation. Nevertheless, there is the need to further enhance the efficiency and effectiveness of SRSs through review of the overall governance model and service delivery to better serve the needs of Member States. The presentation points out some areas of improvements which have already been implemented or are being considered for implementation. Just as important, SRSs are conducted by teams of experts from around the world to strengthening international cooperation, ensure diversity and impartiality, and improve the overall quality of the safety review being conducted. The review team members are also provided with the opportunity for mutual learning and sharing good practices among themselves and with the Member State undergoing the review. As a result, SRAs play an important role in a quest to harmonize regulatory requirements and approaches globally. (author)

  12. Reliability assessment for safety critical systems by statistical random testing

    International Nuclear Information System (INIS)

    Mills, S.E.

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs

  13. Reliability assessment for safety critical systems by statistical random testing

    Energy Technology Data Exchange (ETDEWEB)

    Mills, S E [Carleton Univ., Ottawa, ON (Canada). Statistical Consulting Centre

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs.

  14. A test of safety, violence prevention, and civility climate domain-specific relationships with relevant workplace hazards.

    Science.gov (United States)

    Gazica, Michele W; Spector, Paul E

    2016-01-01

    Safety climate, violence prevention climate, and civility climate were independently developed and linked to domain-specific workplace hazards, although all three were designed to promote the physical and psychological safety of workers. To test domain specificity between conceptually related workplace climates and relevant workplace hazards. Data were collected from 368 persons employed in various industries and descriptive statistics were calculated for all study variables. Correlational and relative weights analyses were used to test for domain specificity. The three climate domains were similarly predictive of most workplace hazards, regardless of domain specificity. This study suggests that the three climate domains share a common higher order construct that may predict relevant workplace hazards better than any of the scales alone.

  15. 78 FR 71036 - Pipeline Safety: Random Drug Testing Rate; Contractor Management Information System Reporting...

    Science.gov (United States)

    2013-11-27

    ... PHMSA-2013-0248] Pipeline Safety: Random Drug Testing Rate; Contractor Management Information System Reporting; and Obtaining Drug and Alcohol Management Information System Sign-In Information AGENCY: Pipeline... Management Information System (MIS) Data; and New Method for Operators to Obtain User Name and Password for...

  16. Expressing best practices in (risk) analysis and testing of safety-critical systems using patterns

    DEFF Research Database (Denmark)

    Herzner, Wolfgang; Sieverding, Sven; Kacimi, Omar

    2014-01-01

    The continuing pervasion of our society with safety-critical cyber-physical systems not only demands for adequate (risk) analysis, testing and verification techniques, it also generates growing experience on their use, which can be considered as important as the tools themselves for their efficient...

  17. A tiered approach to the use of alternatives to animal testing for the safety assessment of cosmetics: skin irritation.

    Science.gov (United States)

    Macfarlane, Martin; Jones, Penny; Goebel, Carsten; Dufour, Eric; Rowland, Joanna; Araki, Daisuke; Costabel-Farkas, Margit; Hewitt, Nicola J; Hibatallah, Jalila; Kirst, Annette; McNamee, Pauline; Schellauf, Florian; Scheel, Julia

    2009-07-01

    Evaluation of the skin irritancy and corrosivity potential of an ingredient is a necessity in the safety assessment of cosmetic ingredients. To date, there are two formally validated alternatives to the rabbit Draize test for skin corrosivity in place, namely the rat skin transcutaneous electrical resistance (TER) assay and the Human Skin Model Test using EpiSkin, EpiDerm and SkinEthic reconstructed human epidermal equivalents. For skin irritation, EpiSkin, EpiDerm and SkinEthic are validated as stand-alone test replacements for the rabbit Draize test. Data from these tests are rarely considered in isolation and are evaluated in combination with other factors to establish the overall irritating or corrosive potential of an ingredient. In light of the deadlines established in the Cosmetics Directive for cessation of animal testing for cosmetic ingredients, a COLIPA scientific meeting was held in Brussels on 30th January, 2008 to review the use of alternative approaches and to set up a decision tree approach for their integration into tiered testing strategies for hazard and safety assessment of cosmetic ingredients and their use in products. In conclusion, the safety assessments for skin irritation/corrosion of new chemicals for use in cosmetics can be confidently accomplished using exclusively alternative methods.

  18. Respiratory symptoms and pulmonary function tests in security and safety products plant workers.

    Science.gov (United States)

    Balbay, Ege Gulec; Toru, Umran; Arbak, Peri; Balbay, Oner; Suner, Kezban Ozmen; Annakkaya, Ali Nihat

    2014-01-01

    Lock and key factory workers are under the risk of metal pneumoconiosis and occupational asthma. In this cross-sectional study, it's aimed to evaluate the relationship between metal dust exposure and respiratory symptoms, pulmonary function tests of workers in different section of lock and key factory. 54 male workers (mean age, 32.8 ± 5.4) in a security and safety products plant were evaluated for respiratory symptoms, pulmonary function tests and smoking habits. Results have been interpreted by comparison of the painting (28/54) and grinding group workers (26/54). There was no significant difference between painting (32.1 ± 4.8) and grinding (33.6 ± 6.1) groups regarding mean age (P > 0.05). Smokers were in significantly higher in grinding group (18/26). Cough and sputum were reported 14.3% (4/28) in painting and 3.8% (1/26) in grinding workers (P > 0.05). Chest tightness was seen in 7.1% and 7.7% of painting and grinding workers, respectively (P > 0.05). But no chest tightness was reported in both groups when they were away work. Breathlessness was seen in 10.7% and 7.7% of painting and grinding workers, respectively (P > 0.05). Breathlessness was similar in both groups (7.1% vs. 3.8%) when they were away work. When comparing painting and grinding workers respiratory functions no significant difference observed. Chest radiography in painting and grinding workers showed hyperlucency (3.6% vs.11.4%), respectively. Painting groups in lock and key factory workers had more but statistically insignificantrespiratory complaints. Interestingly, chest tightness was only observed when both groups were at work. It was thought that ventilation and using personal protective equipment in factory could provide significant benefits.

  19. Black-hole spectroscopy: testing general relativity through gravitational-wave observations

    Energy Technology Data Exchange (ETDEWEB)

    Dreyer, Olaf [Perimeter Institute of Theoretical Physics, 35 King Street North, Waterloo, Ontario, N2J 2G9 (Canada); Kelly, Bernard [Center for Gravitational Wave Physics, Center for Gravitational Physics and Geometry and Department of Physics, 104 Davey Laboratory, University Park, PA 16802 (United States); Krishnan, Badri [Max Planck Institut fuer Gravitationsphysik, Am Muehlenberg 1, D-14476 Golm (Germany); Finn, Lee Samuel [Center for Gravitational Wave Physics, Center for Gravitational Physics and Geometry, Department of Physics and Department of Astronomy and Astrophysics, 104 Davey Laboratory, University Park, PA 16802 (United States); Garrison, David [University of Houston, Clear Lake, 2700 Bay Area Bvd, Room 3531-2, Houston, TX 77058 (United States); Lopez-Aleman, Ramon [Physical Sciences Department, University of Puerto Rico, Rio Piedras Campus, Rio Piedras, Puerto Rico 00931 (Puerto Rico)

    2004-02-21

    Assuming that general relativity is the correct theory of gravity in the strong-field limit, can gravitational-wave observations distinguish between black holes and other compact object sources? Alternatively, can gravitational-wave observations provide a test of one of the fundamental predictions of general relativity: the no-hair theorem? Here we describe a definitive test of the hypothesis that observations of damped, sinusoidal gravitational waves originate from a black hole or, alternatively, that nature respects the general relativistic no-hair theorem. For astrophysical black holes, which have a negligible charge-to-mass ratio, the black-hole quasi-normal mode spectrum is characterized entirely by the black-hole mass and angular momentum and is unique to black holes. In a different theory of gravity, or if the observed radiation arises from a different source (e.g., a neutron star, strange matter or boson star), the spectrum will be inconsistent with that predicted for general relativistic black holes. We give a statistical characterization of the consistency between the noisy observation and the theoretical predictions of general relativity and a demonstration, through simulation, of the effectiveness of the test for strong sources.

  20. Black-hole spectroscopy: testing general relativity through gravitational-wave observations

    International Nuclear Information System (INIS)

    Dreyer, Olaf; Kelly, Bernard; Krishnan, Badri; Finn, Lee Samuel; Garrison, David; Lopez-Aleman, Ramon

    2004-01-01

    Assuming that general relativity is the correct theory of gravity in the strong-field limit, can gravitational-wave observations distinguish between black holes and other compact object sources? Alternatively, can gravitational-wave observations provide a test of one of the fundamental predictions of general relativity: the no-hair theorem? Here we describe a definitive test of the hypothesis that observations of damped, sinusoidal gravitational waves originate from a black hole or, alternatively, that nature respects the general relativistic no-hair theorem. For astrophysical black holes, which have a negligible charge-to-mass ratio, the black-hole quasi-normal mode spectrum is characterized entirely by the black-hole mass and angular momentum and is unique to black holes. In a different theory of gravity, or if the observed radiation arises from a different source (e.g., a neutron star, strange matter or boson star), the spectrum will be inconsistent with that predicted for general relativistic black holes. We give a statistical characterization of the consistency between the noisy observation and the theoretical predictions of general relativity and a demonstration, through simulation, of the effectiveness of the test for strong sources

  1. The role of informal dimensions of safety in high-volume organisational routines: an ethnographic study of test results handling in UK general practice.

    Science.gov (United States)

    Grant, Suzanne; Checkland, Katherine; Bowie, Paul; Guthrie, Bruce

    2017-04-27

    The handling of laboratory, imaging and other test results in UK general practice is a high-volume organisational routine that is both complex and high risk. Previous research in this area has focused on errors and harm, but a complementary approach is to better understand how safety is achieved in everyday practice. This paper ethnographically examines the role of informal dimensions of test results handling routines in the achievement of safety in UK general practice and how these findings can best be developed for wider application by policymakers and practitioners. Non-participant observation was conducted of high-volume organisational routines across eight UK general practices with diverse organisational characteristics. Sixty-two semi-structured interviews were also conducted with the key practice staff alongside the analysis of relevant documents. While formal results handling routines were described similarly across the eight study practices, the everyday structure of how the routine should be enacted in practice was informally understood. Results handling safety took a range of local forms depending on how different aspects of safety were prioritised, with practices varying in terms of how they balanced thoroughness (i.e. ensuring the high-quality management of results by the most appropriate clinician) and efficiency (i.e. timely management of results) depending on a range of factors (e.g. practice history, team composition). Each approach adopted created its own potential risks, with demands for thoroughness reducing productivity and demands for efficiency reducing handling quality. Irrespective of the practice-level approach adopted, staff also regularly varied what they did for individual patients depending on the specific context (e.g. type of result, patient circumstances). General practices variably prioritised a legitimate range of results handling safety processes and outcomes, each with differing strengths and trade-offs. Future safety

  2. Safety diagnosis: are we doing a good job?

    Science.gov (United States)

    Park, Peter Y; Sahaji, Rajib

    2013-03-01

    Collision diagnosis is the second step in the six-step road safety management process described in the AASHTO Highway Safety Manual (HSM). Diagnosis is designed to identify a dominant or abnormally high proportion of particular collision configurations (e.g., rear end, right angle, etc.) at a target location. The primary diagnosis method suggested in the HSM is descriptive data analysis. This type of analysis relies on, for example, pie charts, histograms, and/or collision diagrams. Using location specific collision data (e.g., collision frequency per collision configuration for a target location), safety engineers identify (the most) frequent collision configurations. Safety countermeasures are then likely to concentrate on preventing the selected collision configurations. Although its real-world application in engineering practice is limited, an additional collision diagnosis method, known as the beta-binomial (BB) test, is also presented as the secondary diagnosis tool in the HSM. The BB test compares the proportion of a particular collision configuration observed at one location with the proportion of the same collision configuration found at other reference locations which are similar to the target location in terms of selected traffic and roadway characteristics (e.g., traffic volume, traffic control, and number of lanes). This study compared the outcomes obtained from descriptive data analysis and the BB test, and investigates two questions: (1) Do descriptive data analysis and the BB tests produce the same results (i.e., do they select the same collision configurations at the same locations)? and (2) If the tests produce different results, which result should be adopted in engineering practice? This study's analysis was based on a sample of the most recent five years (2005-2009) of collision and roadway configuration data for 143 signalized intersections in the City of Saskatoon, Saskatchewan. The study results show that the BB test's role in diagnosing

  3. Validation of programmable industrial automation systems for safety critical applications in NPP's dynamic testing

    International Nuclear Information System (INIS)

    Haapanen, P.; Korhonen, J.

    1995-01-01

    The safety assessment of programmable automation systems can not totally be based on conventional probabilistic methods because of the difficulties in quantification of the reliability of the software as well as the hardware. Additional means shall therefore be used to gain more confidence on the system dependability. One central confidence building measure is the independent dynamic testing of the completed system. An automated test harness is needed to run the required large amount of test cases in a restricted time span. The prototype dynamic testing harness for programmable digital systems developed at the Technical Research Centre of Finland (VTT) is described in the presentation. (12 refs., 2 figs., 2 tabs.)

  4. Safety of railroad passenger vehicle dynamics : OMNISIM simulation and test correlations for passenger rail cars

    Science.gov (United States)

    2002-07-01

    The purpose of the work is to validate the safety assessment methodology previously developed for passenger rail vehicle dynamics, which requires the application of simulation tools as well as testing of vehicles under different track scenarios. This...

  5. IEEE Std 600: IEEE trial-use standard requirements for organizations that conduct qualification testing of safety systems equipment for use in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The purpose of this standard is to provide requirements for establishing a program for conducting qualification tests of safety systems equipment used in nuclear power generating stations. Compliance with the requirements of this standard does not assure the adequacy of the qualification tests performed. This standard applies to organizations that conduct qualification tests on equipment that has a definable safety function and is an identifiable part of a safety system for use in nuclear power generating stations. It requires a technical program, a quality assurance program, and a demonstrated ability to meet specified technical requirements. It does not apply to materials tests, production tests, normal performance testing, qualification by analysis, qualification by operating experience, or reliability tests such as diesel-generator multiple start tests. The intent of this standard is to achieve greater consistency, reliability, and reproducibility of test results and to provide adequate control of qualification testing of safety systems equipment

  6. Development of a Test Equipment for Performance Evaluation of Safety Systems

    International Nuclear Information System (INIS)

    Kim, S. J.; Kwon, S. M.; Lee, J. M.; Kim, C. K.; Cho, C. H.; Chun, J. H.; Park, M. K.

    2004-07-01

    The purpose of this study is to develop a test equipment for performance evaluation of safety systems in nuclear power plants. First, we develop an input-output simulator for reactor protection systems, ESF component control systems, and a data acquisition system for these I/O simulators as a hardware for this equipment. Then, we develop a software for human-machine interface system, which is easy-to-use and easy-to-modify. In addition, a simulation tool for a reactor trip switch gear is developed

  7. Physics constraints on the design of fast reactor safety test facilities

    International Nuclear Information System (INIS)

    Travelli, A.; Meneghetti, D.; Matos, J.; Snelgrove, J.; Shaftman, D.H.; Tzanos, C.; Lam, S.K.; Pennington, E.M.; Woodruff, W.L.

    1976-01-01

    This paper discusses the physics foundations common to all fast reactor safety test facilities and the constraints which they impose on the design. While detailed design discussions are confined to the experience with six ANL designs, available data from other designs are used to confirm the validity of the considerations and to broaden the scope of the discussion. This helps to view the various designs as a unified effort, to define their potential capabilities, and to assess how they could best complement each other

  8. Improvement of risk informed surveillance test interval for the safety related instrument and control system of Ulchin units 3 and 4

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Lee, Yun Hwan; Lee, Seung Joon; Han, Sang Hoon

    2012-05-01

    The purpose of this research is the development of various methodologies necessary for the licensing of the risk informed surveillance test interval(STI) improvement for the safety related I and C systems in UCN 3 and 4, for instance, reactor protection system (RPS), engineered safety features actuation system (ESFAS), ESF auxiliary relay cabinet (ARC), and core protection calculator (CPC). The technical adequacy of the methodology was sufficiently verified through the application to the following STI changes. o CPC channel functional test (change from 1 month to 3 months including safety channel and log power test) o RPS channel functional test (change from 1 month to 3 months) o RPS logic and trip channel test (change from 1 month to 3 months. 1 month for RPS manual actuation test) o ESFAS channel functional test (change from 1 month to 3 months) o ESFAS logic and trip channel test (change from 1 month to 3 months) o ESF auxiliary relay test (change from 1 month to 3 months with staggered test. Manual actuation at the ESF ARC is added as a backup of ESF actuation signals during emergency operation

  9. Improvement of risk informed surveillance test interval for the safety related instrumentation and control system of Yonggwang units 3 and 4

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Lee, Yun Hwan; Lee, Seung Joon; Han, Sang Hoon

    2012-05-01

    The purpose of this research is the development of various methodologies necessary for the licensing of the risk informed surveillance test interval(STI) improvement for the safety related I and C systems in YGN 3 and 4, for instance, reactor protection system (RPS), engineered safety features actuation system (ESFAS), ESF auxiliary relay cabinet (ARC), and core protection calculator (CPC). The technical adequacy of the methodology was sufficiently verified through the application to the following STI changes. o CPC channel functional test (change from 1 month to 3 months including safety channel and log power test) o RPS channel functional test (change from 1 month to 3 months) o RPS logic and trip channel test (change from 1 month to 3 months. 1 month for RPS manual actuation test) o ESFAS channel functional test (change from 1 month to 3 months) o ESFAS logic and trip channel test (change from 1 month to 3 months) o ESF auxiliary relay test (change from 1 month to 3 months with staggered test. Manual actuation at the ESF ARC is added as a backup of ESF actuation signals during emergency operation

  10. Technology Development for Integrated Safety Test of Spent Nuclear Fuel Transportation and Storage System

    International Nuclear Information System (INIS)

    Seo, Kiseog; Seo, J. S.; Lee, J. C.

    2012-05-01

    A dedicated review on the U. S. NRC Regulation 10 CFR Part 72 and regulatory guide NUREG/1536 has been performed. The safety requirements for spent nuclear fuel dry storage cask are analyzed and summarized in structural, thermal, shielding, criticality, materials, tests and maintenance aspects. Also a guideline for preparing the safety analysis report is provided. The heat flow analysis was performed by varying the dimensions of the heat flow test facility. From the heat flow analysis for the test facility, as the test facility became test facility. From the heat flow analysis for the test facility, as the test facility became bigger; the thermal effect became smaller. Therefore, the dimensions of the heat flow test facility was designed with 5m Χ 5m Χ 6m(H). Analyses of heat transfer characteristics and mechanism for spent PWR fuel assemblies, option study for production of the effective thermal conductivity and option study for effective thermal conductivity test have been performed to obtain the basic data for production of the effective thermal conductivity. It became clear that the diffusion coefficient of chloride ion of concrete remarkably increases along with the temperature rise, and that there is a linear relation between the logarithm values of the diffusion coefficients and the reciprocal of the temperature. It is understood to be able to express the temperature dependency of the diffusion coefficient roughly by an Arrhenius equation as the velocity coefficient is provided as the diffusion coefficient. The specifications and characteristics of storage facilities under operation including dual purpose casks were investigated. Components subject to material degradation were examined. Based on literature survey, investigating a drop analysis incorporating with material degradation, the basic data to develop an analysis methodology was obtained

  11. Systematic evaluation of non-animal test methods for skin sensitisation safety assessment.

    Science.gov (United States)

    Reisinger, Kerstin; Hoffmann, Sebastian; Alépée, Nathalie; Ashikaga, Takao; Barroso, Joao; Elcombe, Cliff; Gellatly, Nicola; Galbiati, Valentina; Gibbs, Susan; Groux, Hervé; Hibatallah, Jalila; Keller, Donald; Kern, Petra; Klaric, Martina; Kolle, Susanne; Kuehnl, Jochen; Lambrechts, Nathalie; Lindstedt, Malin; Millet, Marion; Martinozzi-Teissier, Silvia; Natsch, Andreas; Petersohn, Dirk; Pike, Ian; Sakaguchi, Hitoshi; Schepky, Andreas; Tailhardat, Magalie; Templier, Marie; van Vliet, Erwin; Maxwell, Gavin

    2015-02-01

    The need for non-animal data to assess skin sensitisation properties of substances, especially cosmetics ingredients, has spawned the development of many in vitro methods. As it is widely believed that no single method can provide a solution, the Cosmetics Europe Skin Tolerance Task Force has defined a three-phase framework for the development of a non-animal testing strategy for skin sensitization potency prediction. The results of the first phase – systematic evaluation of 16 test methods – are presented here. This evaluation involved generation of data on a common set of ten substances in all methods and systematic collation of information including the level of standardisation, existing test data,potential for throughput, transferability and accessibility in cooperation with the test method developers.A workshop was held with the test method developers to review the outcome of this evaluation and to discuss the results. The evaluation informed the prioritisation of test methods for the next phase of the non-animal testing strategy development framework. Ultimately, the testing strategy – combined with bioavailability and skin metabolism data and exposure consideration – is envisaged to allow establishment of a data integration approach for skin sensitisation safety assessment of cosmetic ingredients.

  12. Standardized Observational Assessment of Attention Deficit Hyperactivity Disorder Combined and Predominantly Inattentive Subtypes. I. Test Session Observations

    Science.gov (United States)

    McConaughy, Stephanie H.; Ivanova, Masha Y.; Antshel, Kevin; Eiraldi, Ricardo B.

    2009-01-01

    Test examiners used the Test Observation Form (McConaughy & Achenbach, 2004) to rate test session behavior of 177 6- to 11-year-old children during administration of the Wechsler Intelligence Scale for Children-Fourth Edition (WISC-IV) and Wechsler Individual Achievement Tests-Second Edition (WIAT-II). Participants were assigned to four groups…

  13. Wind Turbine Generator System Safety and Function Test Report for the Entegrity EW50 Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J.; Huskey, A.; Jager, D.; Hur, J.

    2012-11-01

    This report summarizes the results of a safety and function test that NREL conducted on the Entegrity EW50 wind turbine. This test was conducted in accordance with the International Electrotechnical Commissions' (IEC) standard, Wind Turbine Generator System Part 2: Design requirements for small wind turbines, IEC 61400-2 Ed.2.0, 2006-03.

  14. FFTF [Fast Flux Test Facility] performance measurements for safety, productivity and control

    International Nuclear Information System (INIS)

    Newland, D.J.; Praetorius, P.R.; Tomaszewski, T.A.

    1987-05-01

    A useful set of performance measurements for Safety, Productivity and Control has evolved at the Fast Flux Test Facility (FFTF). In response to declining budgets and the resulting need to safely manage a manpower rampdown, an ''Early Warning System'' was developed in 1984. Its purpose was to monitor the effects of the staffing rampdown such that appropriate remedial action could be taken to correct adverse trends before a significant problem occurred. 1 tab

  15. Assessment of food safety practices of food service food handlers (risk assessment data): testing a communication intervention (evaluation of tools).

    Science.gov (United States)

    Chapman, Benjamin; Eversley, Tiffany; Fillion, Katie; Maclaurin, Tanya; Powell, Douglas

    2010-06-01

    Globally, foodborne illness affects an estimated 30% of individuals annually. Meals prepared outside of the home are a risk factor for acquiring foodborne illness and have been implicated in up to 70% of traced outbreaks. The Centers for Disease Control and Prevention has called on food safety communicators to design new methods and messages aimed at increasing food safety risk-reduction practices from farm to fork. Food safety infosheets, a novel communication tool designed to appeal to food handlers and compel behavior change, were evaluated. Food safety infosheets were provided weekly to food handlers in working food service operations for 7 weeks. It was hypothesized that through the posting of food safety infosheets in highly visible locations, such as kitchen work areas and hand washing stations, that safe food handling behaviors of food service staff could be positively influenced. Using video observation, food handlers (n = 47) in eight food service operations were observed for a total of 348 h (pre- and postintervention combined). After the food safety infosheets were introduced, food handlers demonstrated a significant increase (6.7%, P < 0.05, 95% confidence interval) in mean hand washing attempts, and a significant reduction in indirect cross-contamination events (19.6%, P < 0.05, 95% confidence interval). Results of the research demonstrate that posting food safety infosheets is an effective intervention tool that positively influences the food safety behaviors of food handlers.

  16. Cosmic curvature tested directly from observations

    Science.gov (United States)

    Denissenya, Mikhail; Linder, Eric V.; Shafieloo, Arman

    2018-03-01

    Cosmic spatial curvature is a fundamental geometric quantity of the Universe. We investigate a model independent, geometric approach to measure spatial curvature directly from observations, without any derivatives of data. This employs strong lensing time delays and supernova distance measurements to measure the curvature itself, rather than just testing consistency with flatness. We define two curvature estimators, with differing error propagation characteristics, that can crosscheck each other, and also show how they can be used to map the curvature in redshift slices, to test constancy of curvature as required by the Robertson-Walker metric. Simulating realizations of redshift distributions and distance measurements of lenses and sources, we estimate uncertainties on the curvature enabled by next generation measurements. The results indicate that the model independent methods, using only geometry without assuming forms for the energy density constituents, can determine the curvature at the ~6×10‑3 level.

  17. Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment. Research project

    International Nuclear Information System (INIS)

    Martorell, S.; Serradell, V.; Munoz, A.; Sanchez, A.

    1997-01-01

    Background, objective, scope, detailed working plan and follow-up and final product of the project ''Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment'' are described

  18. Development of Onsite Transportation Safety Documents for Nevada Test Site

    International Nuclear Information System (INIS)

    Frank Hand; Willard Thomas; Frank Sciacca; Manny Negrete; Susan Kelley

    2008-01-01

    Department of Energy (DOE) Orders require each DOE site to develop onsite transportation safety documents (OTSDs). The Nevada Test Site approach divided all onsite transfers into two groups with each group covered by a standalone OTSD identified as Non-Nuclear and Nuclear. The Non-Nuclear transfers involve all radioactive hazardous material in less than Hazard Category (HC)-3 quantities and all chemically hazardous materials. The Nuclear transfers involve all radioactive material equal to or greater than HC-3 quantities and radioactive material mated with high explosives regardless of quantity. Both OTSDs comply with DOE O 460.1B requirements. The Nuclear OTSD also complies with DOE O 461.1A requirements and includes a DOE-STD-3009 approach to hazard analysis (HA) and accident analysis as needed. All Nuclear OTSD proposed transfers were determined to be non-equivalent and a methodology was developed to determine if 'equivalent safety' to a fully compliant Department of Transportation (DOT) transfer was achieved. For each HA scenario, three hypothetical transfers were evaluated: a DOT-compliant, uncontrolled, and controlled transfer. Equivalent safety is demonstrated when the risk level for each controlled transfer is equal to or less than the corresponding DOT-compliant transfer risk level. In this comparison the typical DOE-STD-3009 risk matrix was modified to reflect transportation requirements. Design basis conditions (DBCs) were developed for each non-equivalent transfer. Initial DBCs were based solely upon the amount of material present. Route-, transfer-, and site-specific conditions were evaluated and the initial DBCs revised as needed. Final DBCs were evaluated for each transfer's packaging and its contents

  19. 21 CFR 610.11 - General safety.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false General safety. 610.11 Section 610.11 Food and... GENERAL BIOLOGICAL PRODUCTS STANDARDS General Provisions § 610.11 General safety. A general safety test... for administration to humans. The general safety test is required in addition to other specific tests...

  20. Seismic test for safety evaluation of low level radioactive wastes containers

    International Nuclear Information System (INIS)

    Ohoka, Makoto; Horikiri, Morito

    1998-08-01

    Seismic safety of three-piled container system used in Tokai reprocessing center was confirmed by seismic test and computational analysis. Two types of container were evaluated, for low level noninflammable radioactive solid wastes, and for used filters wrapped by large plastic bags. Seismic integrity of three-piled containers was confirmed by evaluating response characteristics such as acceleration and displacement under the design earthquake condition S1, which is the maximum earthquake expected at the stored site during the storage time. Computational dynamic analysis was also performed, and several conclusions described below were made. (1) Response characteristics of the bottom board and the side board were different. The number of pile did not affect the response characteristics of the bottom board of each container. They behaved as a rigid body. (2) The response of the side board was larger than that of the bottom board. (3) The response depended on the direction in each board, either side or bottom. The response acceleration became larger to the seismic wave perpendicular to the plane which has the entrance for fork lift and the radioactive warning mark. (4) The maximum horizontal response displacement under the S1 seismic wave was approximately 10 mm. It is so small that it does not affect the seismic safety. (5) The stoppers to prevent fall down had no influence to the response acceleration. (6) There was no fall down to the S1 seismic wave and 2 times of S1 seismic wave, which was the maximum input condition of the test. (7) The response of the bottom board of the containers, which are main elements of fall down, had good agreements both in the test and in the computational analysis. (author)

  1. Reliability and safety of functional capacity evaluation in patients with whiplash associated disorders.

    Science.gov (United States)

    Trippolini, M A; Reneman, M F; Jansen, B; Dijkstra, P U; Geertzen, J H B

    2013-09-01

    Whiplash-associated disorders (WAD) are a burden for both individuals and society. It is recommended to evaluate patients with WAD at risk of chronification to enhance rehabilitation and promote an early return to work. In patients with low back pain (LBP), functional capacity evaluation (FCE) contributes to clinical decisions regarding fitness-for-work. FCE should have demonstrated sufficient clinimetric properties. Reliability and safety of FCE for patients with WAD is unknown. Thirty-two participants (11 females and 21 males; mean age 39.6 years) with WAD (Grade I or II) were included. The FCE consisted of 12 tests, including material handling, hand grip strength, repetitive arm movements, static arm activities, walking speed, and a 3 min step test. Overall the FCE duration was 60 min. The test-retest interval was 7 days. Interclass correlations (model 1) (ICCs) and limits of agreement (LoA) were calculated. Safety was assessed by a Pain Response Questionnaire, observation criteria and heart rate monitoring. ICCs ranged between 0.57 (3 min step test) and 0.96 (short two-handed carry). LoA relative to mean performance ranged between 15 % (50 m walking test) and 57 % (lifting waist to overhead). Pain reactions after WAD FCE decreased within days. Observations and heart rate measurements fell within the safety criteria. The reliability of the WAD FCE was moderate in two tests, good in five tests and excellent in five tests. Safety-criteria were fulfilled. Interpretation at the patient level should be performed with care because LoA were substantial.

  2. Regulatory risk control through mandatory occupational safety and health (OSH) certification and testing regimes (CTRs)

    NARCIS (Netherlands)

    Zwetsloot, G.I.J.M.; Hale, A.; Zwanikken, S.

    2011-01-01

    Governments make increasing use of private certification and testing infrastructures as an alternative for traditional regulatory arrangements in several areas including occupational safety and health (OSH).This research, commissioned by the Dutch Inspectorate for Work and Income (IWI), concerns an

  3. 75 FR 34064 - Manufactured Home Construction and Safety Standards, Test Procedures for Roof Trusses

    Science.gov (United States)

    2010-06-16

    ... failure. Failure is rupture, fracture, or excessive yielding. (v) Final recovery phase. Remove 2.0 times... members of the public. Commenters should follow the instructions provided on that site to submit comments... nondestructive testing procedure for roof trusses that permits a lower overall factor of safety to be used in...

  4. Instrumentation of fuel safety test rods of the PWR system in the Phebus reactor

    International Nuclear Information System (INIS)

    Schley, Robert; Leveque, J.P.; Aujollet, J.M.; Dutraive, Pierre; Colome, Jean; Bouly, J.C.

    1979-01-01

    The tests were performed in an experimental cell centred in the core of the PHEBUS water reactor of 50 MW. The CEA make two types of apparatus for testing the safety of PWR fuel. One is for testing a single fuel stick and the other a bunch of 25 sticks. The instrumentation described enables the main parameters of the test to be known: temperatures of the fuel - central temperature of the UO 2 - cladding surface temperatures; temperature of the cooling circuits - thermal balance - temperatures of the structures, etc.; coolant pressure; internal pressure of the fuel sticks; direction and flow rate of the fluid. This instrumentation and the technological problems to be overcome are described and the results of the first tests carried out are given [fr

  5. Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

    OpenAIRE

    Hwang Bae; Dong Eok Kim; Sung-Uk Ryu; Sung-Jae Yi; Hyun-Sik Park

    2017-01-01

    Three small-break loss-of-coolant accident (SBLOCA) tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor), i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal–hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are s...

  6. Safety demonstration tests of postulated solvent fire accidents in extraction process of a fuel reprocessing plant, (2)

    International Nuclear Information System (INIS)

    Tukamoto, Michio; Takada, Junichi; Koike, Tadao; Nishio, Gunji; Uno, Seiichiro; Kamoshida, Atsusi; Watanabe, Hironori; Hashimoto, Kazuichiro; Kitani, Susumu.

    1992-03-01

    Demonstration tests of hypothetical solvent fire in an extraction process of the reprocessing plant were carried out from 1984 to 1985 in JAERI, focusing on the confinement of radioactive materials during the fire by a large-scale fire facility (FFF) to evaluate the safety of air-ventilation system in the plant. Fire data from the demonstration test were obtained by focusing on fire behavior at cells and ducts in the ventilation system, smoke generation during the fire, transport and deposition of smoke containing simulated radioactive species in the ventilation system, confinement of radioactive materials, and integrity of HEPA filters by using the FFF simulating an air-ventilation system of the reference reprocessing plant in Japan. The present report is published in a series of the report Phase I (JAERI-M 91-145) of the demonstration test. Test results in the report will be used for the verification of a computer code FACE to evaluate the safety of postulated fire accidents in the reprocessing plant. (author)

  7. Goodness-of-fit tests with dependent observations

    International Nuclear Information System (INIS)

    Chicheportiche, Rémy; Bouchaud, Jean-Philippe

    2011-01-01

    We revisit the Kolmogorov–Smirnov and Cramér–von Mises goodness-of-fit (GoF) tests and propose a generalization to identically distributed, but dependent univariate random variables. We show that the dependence leads to a reduction of the 'effective' number of independent observations. The generalized GoF tests are not distribution-free but rather depend on all the lagged bivariate copulas. These objects, that we call 'self-copulas', encode all the non-linear temporal dependences. We introduce a specific, log-normal model for these self-copulas, for which a number of analytical results are derived. An application to financial time series is provided. As is well known, the dependence is to be long-ranged in this case, a finding that we confirm using self-copulas. As a consequence, the acceptance rates for GoF tests are substantially higher than if the returns were iid random variables

  8. Test to prove the resistance to incidents of components of electric and control systems in the safety containment of nuclear power plants

    International Nuclear Information System (INIS)

    1982-01-01

    The marginal program for proving the suitability of safety-relevant components of electric and control systems in the safety containment during a loss-of-coolant incident is described. Variant test conditions are established in the component-specific test program. Special attention has been paid to the representation of the course of pressure and temperature for the performance test of the valve room of the Nuclear Power Plant Philippsburg 2. (DG) [de

  9. Safety in the Chemical Laboratory: Safety in the Chemistry Laboratories: A Specific Program.

    Science.gov (United States)

    Corkern, Walter H.; Munchausen, Linda L.

    1983-01-01

    Describes a safety program adopted by Southeastern Louisiana University. Students are given detailed instructions on laboratory safety during the first laboratory period and a test which must be completely correct before they are allowed to return to the laboratory. Test questions, list of safety rules, and a laboratory accident report form are…

  10. SIMBOL test facility. Safety aspects. Amended version; SIMBOL experimenteerfaciliteit. Veiligheidsaspecten. Geamendeerde versie

    Energy Technology Data Exchange (ETDEWEB)

    Schoonewelle, H.

    1995-12-01

    A detailed description is given of the bubble chamber SIMBOL at the HOR reactor in Delft, Netherlands, including drawings, applied materials and dimensions. Attention is paid to the nuclear and radiological aspects of the installation and an overview is given of the procedures for the realization, the testing and the operational safety of the chamber. Also the results of a failure and accident analysis are presented. Finally, the dismantlement aspects are dealt with. 5 appendices, 12 refs.

  11. Safety review and stress test of the uranium enrichment facility Gronau; Compact. Sicherheitsueberpruefung und Stresstest der Urananreicherungsanlage Gronau

    Energy Technology Data Exchange (ETDEWEB)

    Kleiboemer, Burkhard [URENCO Deutschland GmbH, Gronau (Germany). Ueberwachung

    2013-07-01

    As a consequence of the earthquake and tsunami in Japan in 2011 and the subsequent catastrophic destruction of the nuclear power plant in Fukushima URENCO has agreed to perform the safety check of the uranium enrichment facility Gronau (UAG) two years earlier than planned. The review was started in May 2011. The contribution deals with the requirements for the safety analysis and the questionnaire for the stress test, the methodology for realization of the safety check and the results of the investigations performed by URENCO and experts of ESK.

  12. Current status of nuclear safety research

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    Efforts at nuclear safety research have expanded year by year in Japan, in term of money and technical achievement. The Atomic Energy Commission set last year the five year nuclear safety research program, a guideline by which various research institutes will be able to develop their own efforts in a concerted manner. From the results of the nuclear safety research which cover very wide areas ranging from reactor engineering safety, safety of nuclear fuel cycle facilities, prevention of radiation hazards to the adequate treatment and disposal of radioactive wastes, AIJ hereafter focuses of LWR engineering safety and prevents two articles, one introducing the current results of the NSSR program developed by JAERI and the other reporting the LWR reliability demonstration testing projects being promoted by MITI. The outline of these demonstration tests was reported in this report. The tests consist of earthquake resistance reliability test of nuclear power plants, steam generator reliability tests, valve integrity tests, fuel assembly reliability tests, reliability tests of heat affected zones and reliability tests of pumps. (Kobatake, H.)

  13. Integral test facilities for validation of the performance of passive safety systems and natural circulation

    International Nuclear Information System (INIS)

    Choi, J. H.

    2010-10-01

    Passive safety systems are becoming an important component in advanced reactor designs. This has led to an international interest in examining natural circulation phenomena as this may play an important role in the operation of these passive safety systems. Understanding reactor system behaviour is a challenging process due to the complex interactions between components and associated phenomena. Properly scaled integral test facilities can be used to explore these complex interactions. In addition, system analysis computer codes can be used as predictive tools in understanding the complex reactor system behaviour. However, before the application of system analysis computer codes for reactor design, it is capability in making predictions needs to be validated against the experimental data from a properly scaled integral test facility. The IAEA has organized a coordinated research project (CRP) on natural circulation phenomena, modeling and reliability of passive systems that utilize natural circulation. This paper is a part of research results from this CRP and describes representative international integral test facilities that can be used for data collection for reactor types in which natural circulation may play an important role. Example experiments were described along with the analyses of these example cases in order to examine the ability of system codes to model the phenomena that are occurring in the test facilities. (Author)

  14. Laboratory testing in management of patients with suspected Ebolavirus disease: infection control and safety.

    Science.gov (United States)

    Gilbert, G L

    2015-08-01

    If routine laboratory safety precautions are followed, the risk of laboratory-acquired infection from handling specimens from patients with Ebolavirus disease (EVD) is very low, especially in the early 'dry' stage of disease. In Australia, border screening to identify travellers returning from EVD-affected west African countries during the 2014-2015 outbreak has made it unlikely that specimens from patients with unrecognised EVD would be sent to a routine diagnostic laboratory. Australian public health and diagnostic laboratories associated with hospitals designated for the care of patients with EVD have developed stringent safety precautions for EVD diagnostic and other tests likely to be required for supportive care of the sickest (and most infectious) patients with EVD, including as wide a range of point-of-care tests as possible. However, it is important that the stringent requirements for packaging, transport and testing of specimens that might contain Ebolavirus--which is a tier 1 security sensitive biology agent--do not delay the diagnosis and appropriate management of other potentially serious but treatable infectious diseases, which are far more likely causes of a febrile illness in people returning from west Africa. If necessary, urgent haematology, biochemistry and microbiological tests can be performed safely, whilst awaiting the results of EVD tests, in a PC-2 laboratory with appropriate precautions including: use of recommended personal protective equipment (PPE) for laboratory staff; handling any unsealed specimens in a class 1 or II biosafety cabinet; using only centrifuges with sealed rotors; and safe disposal or decontamination of all used equipment and laboratory waste.

  15. Safety properties test data selection from an algebraic model of Lustre programs; Selection de tests de proprietes de surete a partir d'une modelisation algebrique de programmes lustre

    Energy Technology Data Exchange (ETDEWEB)

    Hsiao, N.Ch

    1995-07-01

    In the context to validate an industrial software, which is a set of reactive programs, we are confronted with the safety properties verification problem. This thesis reports an experience in which our goal is to generate the test data satisfying a safety property. The software to be validated is designed with the SAGA tool, in which a view can be regarded as a program of a programming language called LUSTRE. We adapt a test data generation tool called LOFT to this kind of programs. In this way, we consider the functional testing method on which the LOFT tool is based. Given any LUSTRE program, we try to give it an algebraic model because LOFT treats algebraic specifications. So, our task consists In defining a formal framework in which any LUSTRE program can be translated into a LOFT module: based on an operational semantics of the LUSTRE language, the flow types 'T-flow' are specified with the constructive algebraic formalism, then implemented in a LOFT modules base. Next, in a test selection process assisted by LOFT, a safety property Is expressed by an equation to join other control hypotheses, and to guide the test data selection. Some concrete test data set are generated in this way on some significant examples. This experience confirm the feasibility of formal method on test data selection for the reactive programs. (author)

  16. Multi-objective optimization of design and testing of safety instrumented systems with MooN voting architectures using a genetic algorithm

    International Nuclear Information System (INIS)

    Torres-Echeverría, A.C.; Martorell, S.; Thompson, H.A.

    2012-01-01

    This paper presents the optimization of design and test policies of safety instrumented systems using MooN voting redundancies by a multi-objective genetic algorithm. The objectives to optimize are the Average Probability of Dangerous Failure on Demand, which represents the system safety integrity, the Spurious Trip Rate and the Lifecycle Cost. In this way safety, reliability and cost are included. This is done by using novel models of time-dependent probability of failure on demand and spurious trip rate, recently published by the authors. These models are capable of delivering the level of modeling detail required by the standard IEC 61508. Modeling includes common cause failure and diagnostic coverage. The Probability of Failure on Demand model also permits to quantify results with changing testing strategies. The optimization is performed using the multi-objective Genetic Algorithm NSGA-II. This allows weighting of the trade-offs between the three objectives and, thus, implementation of safety systems that keep a good balance between safety, reliability and cost. The complete methodology is applied to two separate case studies, one for optimization of system design with redundancy allocation and component selection and another for optimization of testing policies. Both optimization cases are performed for both systems with MooN redundancies and systems with only parallel redundancies. Their results are compared, demonstrating how introducing MooN architectures presents a significant improvement for the optimization process.

  17. Safety Evaluation Test on Human for Radiation Pre vulcanised Natural Rubber Latex (RVNRL)

    International Nuclear Information System (INIS)

    Pairu Ibrahim; Wan Manshol Wan Zain; Chai, Chee Keong; Sofian Ibrahim; Saadiah Sulaiman; Sharifah Ismail

    2010-01-01

    This paper discussed about clinical test conducted to determine safety evaluations on human for latex examination gloves and latex films made from Radiation Vulcanized Natural Rubber Latex (RVNRL). Two types of test were being adopted which are i) Modified Draize-95 test and ii) Patch Test on Sensitized Individuals. Modified Draize-95 test was conducted on 200 non-sensitized human subjects and Patch Test on Sensitized Individuals was conducted on 25 individuals who are allergic to the defined major chemical sensitizer presents in natural rubber product. It was found that Modified Draize-95 test has prove that there is no clinical evidence on the presence of residual chemical additives at the level that may induce Type IV allergy in the un sensitized general user population in the RVNRL gloves. Meanwhile Patch Test on Sensitized Individuals has proved that the patch test conducted using the test article on 25 individuals who are allergic to the defined major chemical sensitizers present in natural rubber products, thiuram, carbamates or thiazoles produced a negative response, meeting the pre requirement for the claim of reduced reaction-inducing potential. (author)

  18. Criticality safety evaluation for the Advanced Test Reactor enhanced low enriched uranium fuel elements

    Energy Technology Data Exchange (ETDEWEB)

    Montierth, Leland M. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-07-19

    The Global Threat Reduction Initiative (GTRI) convert program is developing a high uranium density fuel based on a low enriched uranium (LEU) uranium-molybdenum alloy. Testing of prototypic GTRI fuel elements is necessary to demonstrate integrated fuel performance behavior and scale-up of fabrication techniques. GTRI Enhanced LEU Fuel (ELF) elements based on the ATR-Standard Size elements (all plates fueled) are to be fabricated for testing in the Advanced Test Reactor (ATR). While a specific ELF element design will eventually be provided for detailed analyses and in-core testing, this criticality safety evaluation (CSE) is intended to evaluate a hypothetical ELF element design for criticality safety purposes. Existing criticality analyses have analyzed Standard (HEU) ATR elements from which controls have been derived. This CSE documents analysis that determines the reactivity of the hypothetical ELF fuel elements relative to HEU ATR elements and whether the existing HEU ATR element controls bound the ELF element. The initial calculations presented in this CSE analyzed the original ELF design, now referred to as Mod 0.1. In addition, as part of a fuel meat thickness optimization effort for reactor performance, other designs have been evaluated. As of early 2014 the most current conceptual designs are Mk1A and Mk1B, that were previously referred to as conceptual designs Mod 0.10 and Mod 0.11, respectively. Revision 1 evaluates the reactivity of the ATR HEU Mark IV elements for a comparison with the Mark VII elements.

  19. Criticality safety evaluation for the Advanced Test Reactor enhanced low enriched uranium fuel elements

    International Nuclear Information System (INIS)

    Montierth, Leland M.

    2016-01-01

    The Global Threat Reduction Initiative (GTRI) convert program is developing a high uranium density fuel based on a low enriched uranium (LEU) uranium-molybdenum alloy. Testing of prototypic GTRI fuel elements is necessary to demonstrate integrated fuel performance behavior and scale-up of fabrication techniques. GTRI Enhanced LEU Fuel (ELF) elements based on the ATR-Standard Size elements (all plates fueled) are to be fabricated for testing in the Advanced Test Reactor (ATR). While a specific ELF element design will eventually be provided for detailed analyses and in-core testing, this criticality safety evaluation (CSE) is intended to evaluate a hypothetical ELF element design for criticality safety purposes. Existing criticality analyses have analyzed Standard (HEU) ATR elements from which controls have been derived. This CSE documents analysis that determines the reactivity of the hypothetical ELF fuel elements relative to HEU ATR elements and whether the existing HEU ATR element controls bound the ELF element. The initial calculations presented in this CSE analyzed the original ELF design, now referred to as Mod 0.1. In addition, as part of a fuel meat thickness optimization effort for reactor performance, other designs have been evaluated. As of early 2014 the most current conceptual designs are Mk1A and Mk1B, that were previously referred to as conceptual designs Mod 0.10 and Mod 0.11, respectively. Revision 1 evaluates the reactivity of the ATR HEU Mark IV elements for a comparison with the Mark VII elements.

  20. Nuclear safety

    International Nuclear Information System (INIS)

    Tarride, Bruno

    2015-10-01

    The author proposes an overview of methods and concepts used in the nuclear industry, at the design level as well as at the exploitation level, to ensure an acceptable safety level, notably in the case of nuclear reactors. He first addresses the general objectives of nuclear safety and the notion of acceptable risk: definition and organisation of nuclear safety (relationships between safety authorities and operators), notion of acceptable risk, deterministic safety approach and main safety principles (safety functions and confinement barriers, concept of defence in depth). Then, the author addresses the safety approach at the design level: studies of operational situations, studies of internal and external aggressions, safety report, design principles for important-for-safety systems (failure criterion, redundancy, failure prevention, safety classification). The next part addresses safety during exploitation and general exploitation rules: definition of the operation domain and of its limits, periodic controls and tests, management in case of incidents, accidents or aggressions

  1. Verification and testing of the RTOS for safety-critical embedded systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Na Young [Seoul National University, Seoul (Korea, Republic of); Kim, Jin Hyun; Choi, Jin Young [Korea University, Seoul (Korea, Republic of); Sung, Ah Young; Choi, Byung Ju [Ewha Womans University, Seoul (Korea, Republic of); Lee, Jang Soo [KAERI, Taejon (Korea, Republic of)

    2003-07-01

    Development in Instrumentation and Control (I and C) technology provides more convenience and better performance, thus, adopted in many fields. To adopt newly developed technology, nuclear industry requires rigorous V and V procedure and tests to assure reliable operation. Adoption of digital system requires verification and testing of the OS for licensing. Commercial real-time operating system (RTOS) is targeted to apply to various, unpredictable needs, which makes it difficult to verify. For this reason, simple, application-oriented realtime OS is developed for the nuclear application. In this work, we show how to verify the developed RTOS at each development lifecycle. Commercial formal tool is used in specification and verification of the system. Based on the developed model, software in C language is automatically generated. Tests are performed for two purposes; one is to identify consistency between the verified model and the generated code, the other is to find errors in the generated code. The former assumes that the verified model is correct, and the latter incorrect. Test data are generated separately to satisfy each purpose. After we test the RTOS software, we implement the test board embedded with the developed RTOS and the application software, which simulates the safety critical plant protection function. Testing to identify whether the reliability criteria is satisfied or not is also designed in this work. It results in that the developed RTOS software works well when it is embedded in the system.

  2. Verification and testing of the RTOS for safety-critical embedded systems

    International Nuclear Information System (INIS)

    Lee, Na Young; Kim, Jin Hyun; Choi, Jin Young; Sung, Ah Young; Choi, Byung Ju; Lee, Jang Soo

    2003-01-01

    Development in Instrumentation and Control (I and C) technology provides more convenience and better performance, thus, adopted in many fields. To adopt newly developed technology, nuclear industry requires rigorous V and V procedure and tests to assure reliable operation. Adoption of digital system requires verification and testing of the OS for licensing. Commercial real-time operating system (RTOS) is targeted to apply to various, unpredictable needs, which makes it difficult to verify. For this reason, simple, application-oriented realtime OS is developed for the nuclear application. In this work, we show how to verify the developed RTOS at each development lifecycle. Commercial formal tool is used in specification and verification of the system. Based on the developed model, software in C language is automatically generated. Tests are performed for two purposes; one is to identify consistency between the verified model and the generated code, the other is to find errors in the generated code. The former assumes that the verified model is correct, and the latter incorrect. Test data are generated separately to satisfy each purpose. After we test the RTOS software, we implement the test board embedded with the developed RTOS and the application software, which simulates the safety critical plant protection function. Testing to identify whether the reliability criteria is satisfied or not is also designed in this work. It results in that the developed RTOS software works well when it is embedded in the system

  3. The surgical safety checklist and patient outcomes after surgery: a prospective observational cohort study, systematic review and meta-analysis.

    Science.gov (United States)

    Abbott, T E F; Ahmad, T; Phull, M K; Fowler, A J; Hewson, R; Biccard, B M; Chew, M S; Gillies, M; Pearse, R M

    2018-01-01

    The surgical safety checklist is widely used to improve the quality of perioperative care. However, clinicians continue to debate the clinical effectiveness of this tool. Prospective analysis of data from the International Surgical Outcomes Study (ISOS), an international observational study of elective in-patient surgery, accompanied by a systematic review and meta-analysis of published literature. The exposure was surgical safety checklist use. The primary outcome was in-hospital mortality and the secondary outcome was postoperative complications. In the ISOS cohort, a multivariable multi-level generalized linear model was used to test associations. To further contextualise these findings, we included the results from the ISOS cohort in a meta-analysis. Results are reported as odds ratios (OR) with 95% confidence intervals. We included 44 814 patients from 497 hospitals in 27 countries in the ISOS analysis. There were 40 245 (89.8%) patients exposed to the checklist, whilst 7508 (16.8%) sustained ≥1 postoperative complications and 207 (0.5%) died before hospital discharge. Checklist exposure was associated with reduced mortality [odds ratio (OR) 0.49 (0.32-0.77); P<0.01], but no difference in complication rates [OR 1.02 (0.88-1.19); P=0.75]. In a systematic review, we screened 3732 records and identified 11 eligible studies of 453 292 patients including the ISOS cohort. Checklist exposure was associated with both reduced postoperative mortality [OR 0.75 (0.62-0.92); P<0.01; I 2 =87%] and reduced complication rates [OR 0.73 (0.61-0.88); P<0.01; I 2 =89%). Patients exposed to a surgical safety checklist experience better postoperative outcomes, but this could simply reflect wider quality of care in hospitals where checklist use is routine. Copyright © 2017 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  4. Mining Behavior Based Safety Data to Predict Safety Performance

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey C. Joe

    2010-06-01

    The Idaho National Laboratory (INL) operates a behavior based safety program called Safety Observations Achieve Results (SOAR). This peer-to-peer observation program encourages employees to perform in-field observations of each other's work practices and habits (i.e., behaviors). The underlying premise of conducting these observations is that more serious accidents are prevented from occurring because lower level “at risk” behaviors are identified and corrected before they can propagate into culturally accepted “unsafe” behaviors that result in injuries or fatalities. Although the approach increases employee involvement in safety, the premise of the program has not been subject to sufficient empirical evaluation. The INL now has a significant amount of SOAR data on these lower level “at risk” behaviors. This paper describes the use of data mining techniques to analyze these data to determine whether they can predict if and when a more serious accident will occur.

  5. Safety behavior: Job demands, job resources, and perceived management commitment to safety.

    Science.gov (United States)

    Hansez, Isabelle; Chmiel, Nik

    2010-07-01

    The job demands-resources model posits that job demands and resources influence outcomes through job strain and work engagement processes. We test whether the model can be extended to effort-related "routine" safety violations and "situational" safety violations provoked by the organization. In addition we test more directly the involvement of job strain than previous studies which have used burnout measures. Structural equation modeling provided, for the first time, evidence of predicted relationships between job strain and "routine" violations and work engagement with "routine" and "situational" violations, thereby supporting the extension of the job demands-resources model to safety behaviors. In addition our results showed that a key safety-specific construct 'perceived management commitment to safety' added to the explanatory power of the job demands-resources model. A predicted path from job resources to perceived management commitment to safety was highly significant, supporting the view that job resources can influence safety behavior through both general motivational involvement in work (work engagement) and through safety-specific processes.

  6. Human rights vs. Public safety -- When can you test your workers for drugs?

    Energy Technology Data Exchange (ETDEWEB)

    Kossowan, B. L.

    2002-06-01

    Legislative and regulatory aspects of drug testing of employees vs. public safety are discussed. While in Canada federal and provincial laws concerning human rights take precedence over public safety issues, laws and regulations vary from province to province, therefore there is good reason for concern about uncertainty. To compound the uncertainty, certain relevant laws of the United States are different (generally more stringent than corresponding Canadian laws), consequently there is the possibility that certain American companies might feel justified in refusing to do business with Canadian firms that do not follow their rigid standards. The conclusion is that while the situation may be clear enough in a legal situation, it does not always work equally well in practice. Unfortunately, at the present time there is not a whole lot of guidance available for companies to manage the workplace in a practical sense.

  7. 78 FR 47011 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Science.gov (United States)

    2013-08-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software... revised regulatory guide (RG), revision 1 of RG 1.171, ``Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants.'' This RG endorses American National Standards...

  8. 77 FR 50722 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Science.gov (United States)

    2012-08-22

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software...) is issuing for public comment draft regulatory guide (DG), DG-1208, ``Software Unit Testing for Digital Computer Software used in Safety Systems of Nuclear Power Plants.'' The DG-1208 is proposed...

  9. Optimization of safety equipment outages improves safety

    International Nuclear Information System (INIS)

    Cepin, Marko

    2002-01-01

    Testing and maintenance activities of safety equipment in nuclear power plants are an important potential for risk and cost reduction. An optimization method is presented based on the simulated annealing algorithm. The method determines the optimal schedule of safety equipment outages due to testing and maintenance based on minimization of selected risk measure. The mean value of the selected time dependent risk measure represents the objective function of the optimization. The time dependent function of the selected risk measure is obtained from probabilistic safety assessment, i.e. the fault tree analysis at the system level and the fault tree/event tree analysis at the plant level, both extended with inclusion of time requirements. Results of several examples showed that it is possible to reduce risk by application of the proposed method. Because of large uncertainties in the probabilistic safety assessment, the most important result of the method may not be a selection of the most suitable schedule of safety equipment outages among those, which results in similarly low risk. But, it may be a prevention of such schedules of safety equipment outages, which result in high risk. Such finding increases the importance of evaluation speed versus the requirement of getting always the global optimum no matter if it is only slightly better that certain local one

  10. Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Hwang; Ryu, Sung Uk; Yi, Sung Jae; Park, Hyun Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Dong Eok [Dept. of Precision Mechanical Engineering, Kyungpook National University, Sangju (Korea, Republic of)

    2017-08-15

    Three small-break loss-of-coolant accident (SBLOCA) tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor), i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal–hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are slightly different during the early stage of the transient after a break simulation. A safety injection using a high-pressure pump effectively cools down and recovers the inventory of a reactor coolant system. The global trends show reproducible results for an SBLOCA scenario with three different break locations. It was confirmed that the safety injection system is robustly safe enough to protect from a core uncovery.

  11. Extended Preclinical Safety, Efficacy and Stability Testing of a Live-attenuated Chikungunya Vaccine Candidate.

    Directory of Open Access Journals (Sweden)

    Kenneth S Plante

    Full Text Available We recently described a new, live-attenuated vaccine candidate for chikungunya (CHIK fever, CHIKV/IRES. This vaccine was shown to be well attenuated, immunogenic and efficacious in protecting against CHIK virus (CHIKV challenge of mice and nonhuman primates. To further evaluate its preclinical safety, we compared CHIKV/IRES distribution and viral loads in interferon-α/β receptor-incompetent A129 mice to another CHIK vaccine candidate, 181/clone25, which proved highly immunogenic but mildly reactive in human Phase I/II clinical trials. Compared to wild-type CHIK virus, (wt-CHIKV, both vaccines generated lower viral loads in a wide variety of tissues and organs, including the brain and leg muscle, but CHIKV/IRES exhibited marked restrictions in dissemination and viral loads compared to 181/clone25, and was never found outside the blood, spleen and muscle. Unlike wt-CHIKV, which caused disrupted splenic architecture and hepatic lesions, histopathological lesions were not observed in animals infected with either vaccine strain. To examine the stability of attenuation, both vaccines were passaged 5 times intracranially in infant A129 mice, then assessed for changes in virulence by comparing parental and passaged viruses for footpad swelling, weight stability and survival after subcutaneous infection. Whereas strain 181/clone25 p5 underwent a significant increase in virulence as measured by weight loss (from 30% and mortality (from 0 to 100%, CHIKV/IRES underwent no detectible change in any measure of virulence (no significant weight loss and no mortality. These data indicate greater nonclinical safety of the CHIKV/IRES vaccine candidate compared to 181/clone25, further supporting its eligibility for human testing.

  12. Editorial safety science special issue road safety management.

    NARCIS (Netherlands)

    Wegman, F.C.M. & Hagezieker, M.P.

    2014-01-01

    The articles presented in this Special Issue on Road Safety Management represent an illustration of the growing interest in policy-related research in the area of road safety. The complex nature of this type of research combined with the observation that scientific journals pay limited attention to

  13. GEOMECHANICAL OBSERVATIONS DURING THE LARGE BLOCK TEST

    International Nuclear Information System (INIS)

    STEPHEN C. BLAIR AND STEPHANIE A. WOOD

    1998-01-01

    This paper presents an overview of the geomechanical studies conducted at the Large Block Test at Fran Ridge, near Yucca Mountain, Nevada. The 3-dimensional geomechanical response of the rock to heating is being monitored using instrumentation mounted in boreholes and on the surface of the block. Results show that thermal expansion of the block began a few hours after the start of heating, and is closely correlated with the thermal history. Horizontal expansion increases as a linear function of height. Comparison of observed deformations with continuum simulations shows that below the heater plane deformation is smaller than predicted, while above the heater plane, observed deformation is larger than predicted, and is consistent with opening of vertical fractures. Fracture monitors indicate that movement on a large horizontal fracture is associated with hydrothermal behavior

  14. HIPAA's Individual Right of Access to Genomic Data: Reconciling Safety and Civil Rights.

    Science.gov (United States)

    Evans, Barbara J

    2018-01-04

    In 2014, the United States granted individuals a right of access to their own laboratory test results, including genomic data. Many observers feel that this right is in tension with regulatory and bioethical standards designed to protect the safety of people who undergo genomic testing. This commentary attributes this tension to growing pains within an expanding federal regulatory program for genetic and genomic testing. The Genetic Information Nondiscrimination Act of 2008 expanded the regulatory agenda to encompass civil rights and consumer safety. The individual access right, as it applies to genomic data, is best understood as a civil-rights regulation. Competing regulatory objectives-safety and civil rights-were not successfully integrated during the initial rollout of genomic civil-rights regulations after 2008. Federal law clarifies how to prioritize safety and civil rights when the two come into conflict, although with careful policy design, the two need not collide. This commentary opens a dialog about possible solutions to advance safety and civil rights together. Copyright © 2017 American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  15. The surgical safety checklist and patient outcomes after surgery: a prospective observational cohort study, systematic review and meta-analysis

    NARCIS (Netherlands)

    Abbott, T. E. F.; Ahmad, T.; Phull, M. K.; Fowler, A. J.; Hewson, R.; Biccard, B. M.; Chew, M. S.; Gillies, M.; Pearse, R. M.; Pearse, Rupert M.; Beattie, Scott; Clavien, Pierre-Alain; Demartines, Nicolas; Fleisher, Lee A.; Grocott, Mike; Haddow, James; Hoeft, Andreas; Holt, Peter; Moreno, Rui; Pritchard, Naomi; Rhodes, Andrew; Wijeysundera, Duminda; Wilson, Matt; Ahmed, Tahania; Everingham, Kirsty; Hewson, Russell; Januszewska, Marta; Phull, Mandeep-Kaur; Halliwell, Richard; Shulman, Mark; Myles, Paul; Schmid, Werner; Hiesmayr, Michael; Wouters, Patrick; de Hert, Stefan; Lobo, Suzana; Fang, Xiangming; Rasmussen, Lars; Futier, Emmanuel; Biais, Matthieu; Venara, Aurélien; Slim, Karem; Sander, Michael; Koulenti, Despoina; Arvaniti, Kostoula; Chan, Mathew; Kulkarni, Atul; Chandra, Susilo; Tantri, Aida; Geddoa, Emad; Abbas, Muntadhar; Della Rocca, Giorgio; Sivasakthi, Datin; Mansor, Marzida; Luna, Pastor; Bouwman, Arthur; Buhre, Wolfgang; Beavis, Vanessa; Campbell, Douglas; Short, Tim; Osinaike, Tunde; Matos, Ricardo; Grigoras, Ioana; Kirov, Mikhail; Protsenko, Denis; Biccard, Bruce; Aldecoa, Cesar; Chew, Michelle; Hofer, Christoph; Hubner, Martin; Ditai, James; Szakmany, Tamas; Fleisher, Lee; Ferguson, Marissa; MacMahon, Michael; Cherian, Ritchie; Currow, Helen; Kanathiban, Kathirgamanathan; Gillespie, David; Pathmanathan, Edward; Phillips, Katherine; Reynolds, Jenifer; Rowley, Joanne; Douglas, Jeanene; Kerridge, Ross; Garg, Sameer; Bennett, Michael; Jain, Megha; Alcock, David; Terblanche, Nico; Cotter, Rochelle; Leslie, Kate; Stewart, Marcelle; Zingerle, Nicolette; Clyde, Antony; Hambidge, Oliver; Rehak, Adam; Cotterell, Sharon; Huynh, Wilson Binh Quan; McCulloch, Timothy; Ben-Menachem, Erez; Egan, Thomas; Cope, Jennifer; Fellinger, Paul; Haisjackl, Markus; Haselberger, Simone; Holaubek, Caroline; Lichtenegger, Paul; Scherz, Florian; Hoffer, Franz; Cakova, Veronika; Eichwalder, Andreas; Fischbach, Norbert; Klug, Reinhold; Schneider, Elisabeth; Vesely, Martin; Wickenhauser, Reinhart; Grubmueller, Karl Gernot; Leitgeb, Marion; Lang, Friedrich; Toro, Nancy; Bauer, Marlene; Laengle, Friedrich; Haberl, Claudia; Mayrhofer, Thomas; Trybus, Christoph; Buerkle, Christian; Forstner, Karin; Germann, Reinhard; Rinoesl, Harald; Schindler, Elke; Trampitsch, Ernst; Bogner, Gerhard; Dankl, Daniel; Duenser, Martin; Fritsch, Gerhard; Gradwohl-Matis, Ilse; Hartmann, Andreas; Hoelzenbein, Thomas; Jaeger, Tarkan; Landauer, Franz; Lindl, Gregor; Lux, Michael; Steindl, Johannes; Stundner, Ottokar; Szabo, Christian; Bidgoli, Jawad; Verdoodt, Hans; Forget, Patrice; Kahn, David; Lois, Fernande; Momeni, Mona; Prégardien, Caroline; Pospiech, Audrey; Steyaert, Arnaud; Veevaete, Laurent; de Kegel, Dirk; de Jongh, Karen; Foubert, Luc; Smitz, Carine; Vercauteren, Marcel; Poelaert, Jan; van Mossevelde, Veerle; Abeloos, Jacques; Bouchez, Stefaan; Coppens, Marc; de Baerdemaeker, Luc; Deblaere, Isabel; de Bruyne, Ann; Fonck, Kristine; Heyse, Bjorn; Jacobs, Tom; Lapage, Koen; Moerman, Anneliese; Neckebroek, Martine; Parashchanka, Aliaksandra; Roels, Nathalie; van den Eynde, Nancy; Vandenheuvel, Michael; Limmen, JurgenVan; Vanluchene, Ann; Vanpeteghem, Caroline; Wyffels, Piet; Huygens, Christel; Vandenbempt, Punitha; van de Velde, Marc; Dylst, Dimitri; Janssen, Bruno; Schreurs, Evelien; Aleixo, Fábia Berganton; Candido, Keulle; Batista, Hugo Dias; Guimarães, Mario; Guizeline, Jaqueline; Hoffmann, João; Lobo, Francisco Ricardo Marques; Nascimento, Vinícius; Nishiyama, Katia; Pazetto, Lucas; Souza, Daniela; Rodrigues, Rodrigo Souza; Vilela Dos Santos, Ana Maria; Jardim, Jaquelline; Sá Malbouisson, Luiz Marcelo; Silva, Joao; Nascimento Junior, Paulo do; Baio, Thalissa Hermínia; Pereira de Castro, Gabriel Isaac; Watanabe Oliveira, Henri Roger; Amendola, Cristina Prata; Cardoso, Gutemberg; Ortega, Daniela; Brotto, Ana Flavia; de Oliveira, Mirella Cristine; Réa-Neto, Álvaro; Dias, Fernando; Travi, Maria Eduarda; Zerman, Luiza; Azambuja, Pedro; Knibel, Marcos Freitas; Martins, Antonio; Almeida, William; Neto, Calim Neder; Tardelli, Maria Angela; Caser, Eliana; Machado, Marcio; Aguzzoli, Crisitiano; Baldisserotto, Sérgio; Tabajara, Fernanda Beck; Bettega, Fernanda; Rodrigues Júnior, La Hore Correa; de Gasperi, Julia; Faina, Lais; Nolasco, Marcos Farias; Ferreira da Costa Fischer, Bruna; Fosch de Campos Ferreira, Mariana; Hartmann, Cristina; Kliemann, Marta; Hubert Ribeiro, Gustavo Luis; Fraga, Julia Merladete; Netto, Thiago Motta; Pozza, Laura Valduga; Wendling, Paulo Rafael; Azevedo, Caroline; Garcia, Juliana; Lopes, Marcel; Maia, Bernardo; Maselli, Paula; Melo, Ralph; Mendes, Weslley; Neves, Matheus; Ney, Jacqueline; Piras, Claudio; Applewhaite, Christopher; Carr, Adrienne; Chow, Lorraine; Duttchen, Kaylene; Foglia, Julena; Greene, Michael; Hinther, Ashley; Houston, Kendra; McCormick, Thomas Jared; Mikhayel, Jennifer; Montasser, Sam; Ragan, Alex; Suen, Andrew; Woolsey, Adrianna; Yu, Hai Chuan; Funk, Duane; Kowalski, Stephen; Legaspi, Regina; McDonald, Heather; Siddiqui, Faisal; Pridham, Jeremy; Rowe, Bernadette; Sampson, Sonia; Thiessen, Barton; Zbitnew, Geoff; Bernard, Andre; George, Ronald; Jones, Philip; Moor, Rita; Siddiqui, Naveed; Wolfer, Alexandra; Tran, Diem; Winch, Denyse; Dobson, Gary; McCormick, Thomas; Montasser, Osama; Hall, Richard; Baghirzada, Leyla; Curley, Gerard; Dai, Si Yuan; Hare, Gregory; Lee, Esther; Shastri, Uma; Tsui, Albert; Yagnik, Anmol; Alvares, Danielle; Choi, Stephen; Dwyer, Heather; Flores, Kathrina; McCartney, Colin; Somascanthan, Priya; Carroll, Jo; Pazmino-Canizares, Janneth; Ami, Noam; Chan, Vincent; Perlas, Anahi; Argue, Ruth; Huang, Yang; Lavis, Katie; Mayson, Kelly; Cao, Ying; Gao, Hong; Hu, Tingju; Lv, Jie; Yang, Jian; Yang, Yang; Zhong, Yi; Zhou, Jing; Zou, Xiaohua; He, Miao; Li, Xiaoying; Luo, Dihuan; Wang, Haiying; Yu, Tian; Chen, Liyong; Wang, Lijun; Cai, Yunfei; Cao, Zhongming; Li, Yanling; Lian, Jiaxin; Sun, Haiyun; Wang, Sheng; Wang, Zhipeng; Wang, Kenru; Zhu, Yi; Du, Xindan; Fan, Hao; Fu, Yunbin; Huang, Lixia; Huang, Yanming; Hwan, Haifang; Luo, Hong; Qu, Pi-Sheng; Tao, Fan; Wang, Zhen; Wang, Guoxiang; Wang, Shun; Zhang, Yan; Zhang, Xiaolin; Chen, Chao; Wang, Weixing; Liu, Zhengyuan; Fan, Lihua; Tang, Jing; Chen, Yijun; Chen, Yongjie; Han, Yangyang; Huang, Changshun; Liang, Guojin; Shen, Jing; Wang, Jun; Yang, Qiuhong; Zhen, Jungang; Zhou, Haidong; Chen, Junping; Chen, Zhang; Li, Xiaoyu; Meng, Bo; Ye, Haiwang; Zhang, Xiaoyan; Bi, Yanbing; Cao, Jianqiao; Guo, Fengying; Lin, Hong; Liu, Yang; Lv, Meng; Shi, Pengcai; Song, Xiumei; Sun, Chuanyu; Sun, Yongtao; Wang, Yuelan; Wang, Shenhui; Zhang, Min; Chen, Rong; Hou, Jiabao; Leng, Yan; Meng, Qing-Tao; Qian, Li; Shen, Zi-Ying; Xia, Zhong-Yuan; Xue, Rui; Zhang, Yuan; Zhao, Bo; Zhou, Xian-Jin; Chen, Qiang; Guo, Huinan; Guo, Yongqing; Qi, Yuehong; Wang, Zhi; Wei, Jianfeng; Zhang, Weiwei; Zheng, Lina; Bao, Qi; Chen, Yaqiu; Chen, Yijiao; Fei, Yue; Hu, Nianqiang; Hu, Xuming; Lei, Min; Li, Xiaoqin; Lv, Xiaocui; Miao, Fangfang; Ouyang, Lingling; Qian, Lu; Shen, Conyu; Sun, Yu; Wang, Yuting; Wang, Dong; Wu, Chao; Xu, Liyuan; Yuan, Jiaqi; Zhang, Lina; Zhang, Huan; Zhang, Yapping; Zhao, Jinning; Zhao, Chong; Zhao, Lei; Zheng, Tianzhao; Zhou, Dachun; Zhou, Haiyan; Zhou, Ce; Lu, Kaizhi; Zhao, Ting; He, Changlin; Chen, Hong; Chen, Shasha; Cheng, Baoli; He, Jie; Jin, Lin; Li, Caixia; Li, Hui; Pan, Yuanming; Shi, Yugang; Wen, Xiao Hong; Wu, Shuijing; Xie, Guohao; Zhang, Kai; Zhao, Bing; Lu, Xianfu; Chen, Feifei; Liang, Qisheng; Lin, Xuewu; Ling, Yunzhi; Liu, Gang; Tao, Jing; Yang, Lu; Zhou, Jialong; Chen, Fumei; Cheng, Zhonggui; Dai, Hanying; Feng, Yunlin; Hou, Benchao; Gong, Haixia; Hu, Chun Hua; Huang, Haijin; Huang, Jian; Jiang, Zhangjie; Li, Mengyuan; Lin, Jiamei; Liu, Mei; Liu, Weicheng; Liu, Zhen; Liu, Zhiyi; Luo, Foquan; Ma, Longxian; Min, Jia; Shi, Xiaoyun; Song, Zhiping; Wan, Xianwen; Xiong, Yingfen; Xu, Lin; Yang, Shuangjia; Zhang, Qin; Zhang, Hongyan; Zhang, Huaigen; Zhang, Xuekang; Zhao, Lili; Zhao, Weihong; Zhao, Weilu; Zhu, Xiaoping; Bai, Yun; Chen, Linbi; Chen, Sijia; Dai, Qinxue; Geng, Wujun; Han, Kunyuan; He, Xin; Huang, Luping; Ji, Binbin; Jia, Danyun; Jin, Shenhui; Li, Qianjun; Liang, Dongdong; Luo, Shan; Lwang, Lulu; Mo, Yunchang; Pan, Yuanyuan; Qi, Xinyu; Qian, Meizi; Qin, Jinling; Ren, Yelong; Shi, Yiyi; Wang, Junlu; Wang, Junkai; Wang, Leilei; Xie, Junjie; Yan, Yixiu; Yao, Yurui; Zhang, Mingxiao; Zhao, Jiashi; Zhuang, Xiuxiu; Ai, Yanqiu; Du, Fang; He, Long; Huang, Ledan; Li, Zhisong; Li, Huijuan; Li, Yetong; Li, Liwei; Meng, Su; Yuan, Yazhuo; Zhang, Enman; Zhang, Jie; Zhao, Shuna; Ji, Zhenrong; Pei, Ling; Wang, Li; Chen, Chen; Dong, Beibei; Li, Jing; Miao, Ziqiang; Mu, Hongying; Qin, Chao; Su, Lin; Wen, Zhiting; Xie, Keliang; Yu, Yonghao; Yuan, Fang; Hu, Xianwen; Zhang, Ye; Xiao, Wangpin; Zhu, Zhipeng; Dai, Qingqing; Fu, Kaiwen; Hu, Rong; Hu, Xiaolan; Huang, Song; Li, Yaqi; Liang, Yingping; Yu, Shuchun; Guo, Zheng; Jing, Yan; Tang, Na; Wu, Jie; Yuan, Dajiang; Zhang, Ruilin; Zhao, Xiaoying; Li, Yuhong; Bai, Hui-Ping; Liu, Chun-Xiao; Liu, Fei-Fei; Ren, Wei; Wang, Xiu-Li; Xu, Guan-Jie; Hu, Na; Li, Bo; Ou, Yangwen; Tang, Yongzhong; Yao, Shanglong; Zhang, Shihai; Kong, Cui-Cui; Liu, Bei; Wang, Tianlong; Xiao, Wei; Lu, Bo; Xia, Yanfei; Zhou, Jiali; Cai, Fang; Chen, Pushan; Hu, Shuangfei; Wang, Hongfa; Xu, Qiong; Hu, Liu; Jing, Liang; Li, Bin; Liu, Qiang; Liu, Yuejiang; Lu, Xinjian; Peng, Zhen Dan; Qiu, Xiaodong; Ren, Quan; Tong, Youliang; Wang, Jin; Wen, Yazhou; Wu, Qiong; Xia, Jiangyan; Xie, Jue; Xiong, Xiapei; Xu, Shixia; Yang, Tianqin; Ye, Hui; Yin, Ning; Yuan, Jing; Zeng, Qiuting; Zhang, Baoling; Zheng, Kang; Cang, Jing; Chen, Shiyu; Fan, Yu; Fu, Shuying; Ge, Xiaodong; Guo, Baolei; Huang, Wenhui; Jiang, Linghui; Jiang, Xinmei; Liu, Yi; Pan, Yan; Ren, Yun; Shan, Qi; Wang, Jiaxing; Wang, Fei; Wu, Chi; Zhang, Xiaoguang; Christiansen, Ida Cecilie; Granum, Simon Nørgaard; Rasmussen, Bodil Steen; Daugaard, Morten; Gambhir, Rajiv; Brandsborg, Birgitte; Steingrímsdóttir, Guðný Erla; Jensen-Gadegaard, Peter; Olsen, Karsten Skovgaard; Siegel, Hanna; Eskildsen, Katrine Zwicky; Gätke, Mona Ring; Wibrandt, Ida; Heintzelmann, Simon Bisgaard; Wiborg Lange, Kai Henrik; Lundsgaard, Rune Sarauw; Amstrup-Hansen, Louise; Hovendal, Claus; Larsen, Michael; Lenstrup, Mette; Kobborg, Tina; Larsen, Jens Rolighed; Pedersen, Anette Barbre; Smith, Søren Hübertz; Oestervig, Rebecca Monett; Afshari, Arash; Andersen, Cheme; Ekelund, Kim; Secher, Erik Lilja; Beloeil, Helene; Lasocki, Sigismond; Ouattara, Alexandre; Sineus, Marlene; Molliex, Serge; Legouge, Marie Lim; Wallet, Florent; Tesniere, Antoine; Gaudin, Christophe; Lehur, Paul; Forsans, Emma; de Rudnicki, Stéphane; Maudet, Valerie Serra; Mutter, Didier; Sojod, Ghassan; Ouaissi, Mehdi; Regimbeau, Jean-Marc; Desbordes, Jacques; Comptaer, Nicolas; Manser, Diae El; Ethgen, Sabine; Lebuffe, Gilles; Auer, Patrick; Härtl, Christine; Deja, Maria; Legashov, Kirill; Sonnemann, Susanne; Wiegand-Loehnert, Carola; Falk, Elke; Habicher, Marit; Angermair, Stefan; Laetsch, Beatrix; Schmidt, Katrin; von Heymann, Christian; Ramminger, Axel; Jelschen, Florian; Pabel, Svenja; Weyland, Andreas; Czeslick, Elke; Gille, Jochen; Malcharek, Michael; Sablotzki, Armin; Lueke, Katharina; Wetzel, Peter; Weimann, Joerg; Lenhart, Franz-Peter; Reichle, Florian; Schirmer, Frederike; Hüppe, Michael; Klotz, Karl; Nau, Carla; Schön, Julika; Mencke, Thomas; Wasmund, Christina; Bankewitz, Carla; Baumgarten, Georg; Fleischer, Andreas; Guttenthaler, Vera; Hack, Yvonne; Kirchgaessner, Katharina; Männer, Olja; Schurig-Urbaniak, Marlen; Struck, Rafael; van Zyl, Rebekka; Wittmann, Maria; Goebel, Ulrich; Harris, Sarah; Veit, Siegfried; Andreadaki, Evangelia; Souri, Flora; Katsiadramis, Ioannis; Skoufi, Anthi; Vasileiou, Maria; Aimoniotou-Georgiou, Eleni; Katsourakis, Anastasios; Veroniki, Fotini; Vlachogianni, Glyceria; Petra, Konstantina; Chlorou, Dimitra; Oloktsidou, Eirini; Ourailoglou, Vasileios; Papapostolou, Konstantinos; Tsaousi, Georgia; Daikou, Panagoula; Dedemadi, Georgia; Kalaitzopoulos, Ioannis; Loumpias, Christos; Bristogiannis, Sotirios; Dafnios, Nikolaos; Gkiokas, Georgios; Kontis, Elissaios; Kozompoli, Dimitra; Papailia, Aspasia; Theodosopoulos, Theodosios; Bizios, Christol; Koutsikou, Anastasia; Moustaka, Aleaxandra; Plaitakis, Ioannis; Armaganidis, Apostolos; Christodoulopoulou, Theodora; Lignos, Mihail; Theodorakopoulou, Maria; Asimakos, Andreas; Ischaki, Eleni; Tsagkaraki, Angeliki; Zakynthinos, Spyros; Antoniadou, Eleni; Koutelidakis, Ioannis; Lathyris, Dimitrios; Pozidou, Irene; Voloudakis, Nikolaos; Dalamagka, Maria; Elena, Gkonezou; Chronis, Christos; Manolakaki, Dimitra; Mosxogiannidis, Dimitris; Slepova, Tatiana; Tsakiridou, Isaia-Sissy; Lampiri, Claire; Vachlioti, Anastasia; Panagiotakis, Christos; Sfyras, Dimitrios; Tsimpoukas, Fotios; Tsirogianni, Athanasia; Axioti, Elena; Filippopoulos, Andreas; Kalliafa, Elli; Kassavetis, George; Katralis, Petros; Komnos, Ioannis; Pilichos, Georgios; Ravani, Ifigenia; Totis, Antonis; Apagaki, Eymorfia; Efthymiadi, Andromachi; Kampagiannis, Nikolaos; Paraforou, Theoniki; Tsioka, Agoritsa; Georgiou, Georgios; Vakalos, Aristeidis; Bairaktari, Aggeliki; Charitos, Efthimios; Markou, George; Niforopoulou, Panagiota; Papakonstantinou, Nikolaos; Tsigou, Evdoxia; Xifara, Archontoula; Zoulamoglou, Menelaos; Gkioni, Panagiota; Karatzas, Stylianos; Kyparissi, Aikaterini; Mainas, Efstratios; Papapanagiotou, Ioannis; Papavasilopoulou, Theonymfi; Fragandreas, George; Georgopoulou, Eleni; Katsika, Eleni; Psarras, Kyriakos; Synekidou, Eirini; Verroiotou, Maria; Vetsiou, Evangelia; Zaimi, Donika; Anagnou, Athina; Apostolou, Konstantinos; Melissopoulou, Theodora; Rozenberg, Theophilos; Tsigris, Christos; Boutsikos, Georgios; Kalles, Vasileios; Kotsalas, Nikolaos; Lavdaiou, Christina; Paikou, Fotini; Panagou, Georgia-Laura; Spring, Anna; Botis, Ioannis; Drimala, Maria; Georgakakis, Georgios; Kiourtzieva, Ellada; Ntouma, Panagiota; Prionas, Apostolos; Xouplidis, Kyriakos; Dalampini, Eleftheria; Giannaki, Chrysavgi; Iasonidou, Christina; Ioannidis, Orestis; Lavrentieva, Athina; Lavrentieva, Athena; Papageorgiou, George; Kokkinoy, Maria; Stafylaraki, Maria; Gaitanakis, Stylianos; Karydakis, Periclis; Paltoglou, Josef; Ponireas, Panagiotis; Chaloulis, Panagiotis; Provatidis, Athanasios; Sousana, Anisoglou; Gardikou, Varvara Vanessa; Konstantivelli, Maria; Lataniotou, Olga; Lisari, Elisavet; Margaroni, Maria; Stamatiou, Konstantinos; Nikolaidis, Edouardos; Pnevmatikos, Ioannis; Sertaridou, Eleni; Andreou, Alexandros; Arkalaki, Eleni; Athanasakis, Elias; Chaniotaki, Fotini; Chatzimichali, Chatzimichali Aikaterini; Christofaki, Maria; Dermitzaki, Despina; Fiorentza, Klara; Frantzeskos, Georgios; Geromarkaki, Elisavet; Kafkalaki, Kalliopi; Kalogridaki, Marina; Karydi, Konstyllia; Kokkini, Sofia; Kougentakis, Georgios; Lefaki, Tatiana; Lilitsis, Emmanouhl; Makatounaki, Aikaterini; Malliotakis, Polychronis; Michelakis, Dimosthenis; Neonaki, Maria; Nyktari, Vasileia; Palikyra, Iliana; Papadakis, Eleftherios; Papaioannou, Alexandra; Sfakianakis, Konstantinos; Sgouraki, Maria; Souvatzis, Xenia; Spartinou, Anastasia; Stefanidou, Nefeli; Syrogianni, Paulina; Tsagkaraki, Georgia; Arnaoutoglou, Elena; Arnaoutoglou, Christina; Bali, Christina; Bouris, Vasilios; Doumos, Rodamanthos; Gkini, Konstantia-Paraskevi; Kapaktsi, Clio; Koulouras, Vasilios; Lena, Arian; Lepida, Dimitra; Michos, Evangelos; Papadopoulos, Dimitrios; Paschopoulos, Minas; Rompou, Vaia Aliki; Siouti, Ioanna; Tsampalas, Stavros; Ververidou, Ourania; Zilis, Georgios; Charlalampidoy, Alexandra; Christodoulidis, Gregory; Flossos, Andreas; Stamoulis, Konstantinos; Chan, Matthew; Tsang, Man Shing Caleb; Tsang, Man Shing; Lai, Man Ling; Yip, Chi Pang; Heymans Chan, Hey Man; Law, Bassanio; Li, Wing Sze; Chu, Hiu Man; Koo, Emily Gar Yee; Lam, Chi Cheong Joe; Cheng, Ka Ho; Lam, Tracy; Chu, Susanna; Lam, Wing Yan; Wong, Kin Wai Kevin; Kwok, Dilys; Hung, Ching Yue Janice; Chan, Wai Kit Jacky; Wong, Wing Lam; Chung, Chun Kwong Eric; Ma, Shu Kai; Kaushik, Shuchi; Shah, Bhagyesh; Shah, Dhiren; Shah, Sanjay; Ar, Praburaj; Muthuchellappan, Radhakrishnan; Agarwal, Vandana; Divatia, Jigeeshu; Mishra, Sanghamitra; Nimje, Ganesh; Pande, Swati; Savarkar, Sukhada; Shrivastava, Aditi; Thomas, Martin; Yegnaram, Shashikant; Hidayatullah, Rahmat; Puar, Nasman; Niman, Sumara; Indra, Imai; Hamzah, Zulkarnain; Yuliana, Annika; Abidin, Ucu Nurhadiat; Dursin, Ade Nurkacan; Kurnia, Andri; Susanti, Ade; Handayani, Dini; Alit, Mahaalit Aribawa; Arya, Aryabiantara; Senapathi, Tjokorda Gde Agung; Utara, Utara Hartawan; Wid, Widnyana Made; Wima, Semarawima; Wir, Wiryana Made; Jehosua, Brillyan; Kaunang, Jonathan; Lantang, Eka Yudha; Najoan, Rini; Waworuntu, Neil; Awad, Hadi; Fuad, Akram; Geddoa, Burair; Khalaf, Abdel Razzaq; Al Hussaini, Sabah; Albaj, Safauldeensalem; Kenber, Maithem; Bettinelli, Alessandra; Spadaro, Savino; AlbertoVolta, Carlo; Giancarlo, Luigi; Sottosanti, Vicari; Copetti, Elisa; Spagnesi, Lorenzo; Toretti, Ilaria; Alloj, Chiara; Cardellino, Silvano; Carmino, Livio; Costanzo, Eleonora; Fanfani, Lucia Caterina; Novelli, Maria Teresa; Roasio, Agostino; Bellandi, Mattia; Beretta, Luigi; Bignami, Elena; Bocchino, Speranza; Cabrini, Luca; Corti, Daniele; Landoni, Giovanni; Meroni, Roberta; Moizo, Elena; Monti, Giacomo; Pintaudi, Margherita; Plumari, Valentina Paola; Taddeo, Daiana; Testa, Valentina; Winterton, Dario; Zangrillo, Alberto; Cloro, Luigi Maria; Colangelo, Chiara; Colangelo, Antonio; Rotunno, Giuseppe; Paludi, Miguel Angel; Maria, Cloro Paolo; Pata, Antonio; Parrini, Vieri; Gatta, Alessandro; Nastasi, Mauro; Tinti, Carla; Baroselli, Antonio; Arrigo, Mario; Benevento, Angelo; Bottini, Corrado; Cannavo', Maurizio; Gastaldi, Christian; Marchesi, Alessandro; Pascazio, Angelantonio; Pata, Francesco; Pozzi, Emilio; Premoli, Alberto; Tessera, Gaetano; Boschi, Luca; D'Andrea, Rocco; Ghignone, Federico; Poggioli, Gilberto; Sibilio, Andrea; Taffurelli, Mario; Ugolini, Giampaolo; Ab Majid, Mohd Azuan; Ab Rahman, Rusnah; Joseph, James; Pathan, Furquan; Sybil Shah, Mohammad Hafizshah; Yap, Huey Ling; Cheah, Seleen; Chin, Im Im; Looi, Ji Keon; Tan, Siew Ching; Visvalingam, Sheshendrasurian; Kwok, Fan Yin; Lee, Chew Kiok; Tan, Tse Siang; Wong, Sze Meng; Abdullah, Noor Hairiza; Liew, Chiat Fong; Luxuman, Lovenia; Mohd Zin, Nor Hafizah; Norddin, Muhamad Faiz; Raja Alias, Raja Liza; Wong, Juan Yong; Yong, Johnny; Bin Mustapha, Mohd Tarmimi; Chan, Weng Ken; Dzulkipli, Norizawati; Kuan, Pei Xuan; Lee, Yew Ching; Alias, Anita; Guok, Eng Ching; Jee, Chiun Chen; Ramon, Brian Rhadamantyne; Wong, Cheng Weng; Abd Ghafar, Fara Nur Idayu; Aziz, Faizal Zuhri; Hussain, Nabilah; Lee, Hooi Sean; Sukawi, Ismawaty; Woon, Yuan Liang; Abd Hadi, Husni Zaeem; Ahmad Azam, Ummi Azmira; Alias, Abdul Hafiz; Kesut, Saiful Aizar; Lee, Jun May; Ooi, Dar Vin; Sulaiman, Hetty Ayuni; Lih, Tengku Alini Tengku; Veerakumaran, Jeyaganesh; Rojas, Eder; Resendiz, Gerardo Esteban Alvarez; Zapata, Darcy Danitza Mari; López, Julio Cesar Jesús Aguilar; Flores, Armando Adolfo Alvarez; Amador, Juan Carlos Bravo; Avila, Erendira Jocelin Dominguez; Aquino, Laura Patricia González; Rodriguez, Ricardo Lopez; Landa, Mariana Torres; Urias, Emma; Hollmann, Markus; Hulst, Abraham; Preckel, Benedikt; Koopman-van Gemert, Ankie; Buise, Marc; Tolenaar, Noortje; Weber, Eric; de Fretes, Jennifer; Houweling, Peter; Ormskerk, Patricia; van Bommel, Jasper; Lance, Marcus; Smit-Fun, Valerie; van Zundert, Tom; Baas, Peter; Donald de Boer, Hans; Sprakel, Joost; Elferink-Vonk, Renske; Noordzij, Peter; van Zeggeren, Laura; Brand, Bastiaan; Spanjersberg, Rob; ten Bokkel-Andela, Janneke; Numan, Sandra; van Klei, Wilton; van Zaane, Bas; Boer, Christa; van Duivenvoorde, Yoni; Hering, Jens Peter; van Rossum, Sylvia; Zonneveldt, Harry; Campbell, Doug; Hoare, Siobhan; Santa, Sahayam; Ali, Marlynn; Allen, Sara Jane; Bell, Rachel; Choi, Hyun-Min David; Drake, Matthew; Farrell, Helen; Hayes, Katia; Higgie, Kushlin; Holmes, Kerry; Jenkins, Nicole; Kim, Chang Joon; Kim, Steven; Law, Kiew Chai; McAllister, Davina; Park, Karen; Pedersen, Karen; Pfeifer, Leesa; Pozaroszczyk, Anna; Salmond, Timothy; Steynor, Martin; Tan, Michael; Waymouth, Ellen; Ab Rahman, Ahmad Sufian; Armstrong, John; Dudson, Rosie; Jenkins, Nia; Nilakant, Jayashree; Richard, Seigne; Virdi, Pardeep; Dixon, Liane; Donohue, Roana; Farrow, Mehreen; Kennedy, Ross; Marissa, Henderson; McKellow, Margie; Nicola, Delany; Pascoe, Rebecca; Roberts, Stephen John; Rowell, George; Sumner, Matthew; Templer, Paul; Chandrasekharan, Shardha; Fulton, Graham; Jammer, Ib; More, Richard; Wilson, Leona; Chang, Yuan Hsuan; Foley, Julia; Fowler, Carolyn; Panckhurst, Jonathan; Sara, Rachel; Stapelberg, Francois; Cherrett, Veronica; Ganter, Donna Louise; McCann, Lloyd; Gilmour, Fiona; Lumsden, Rachelle; Moores, Mark; Olliff, Sue; Sardareva, Elitza; Tai, Joyce; Wikner, Matthew; Wong, Christopher; Chaddock, Mark; Czepanski, Carolyn; McKendry, Patrick; Polakovic, Daniel; Polakovich, Daniel; Robert, Axe; Belda, Margarita Tormo; Norton, Tracy; Alherz, Fadhel; Barneto, Lisa; Ramirez, Alberto; Sayeed, Ahmed; Smith, Nicola; Bennett, Cambell; McQuoid, Shane; Jansen, Tracy-Lee; Nico, Zin; Scott, John; Freschini, David; Freschini, Angela; Hopkins, Brian; Manson, Lara; Stoltz, Deon; Bates, Alexander; Davis, Simon; Freeman, Victoria; McGaughran, Lynette; Williams, Maya; Sharma, Swarna Baskar; Burrows, Tom; Byrne, Kelly; English, Duane; Johnson, Robert; Manikkam, Brendon; Naidoo, Shaun; Rumball, Margot; Whittle, Nicola; Franks, Romilla; Gibson-Lapsley, Hannah; Salter, Ryan; Walsh, Dean; Cooper, Richard; Perry, Katherine; Obobolo, Amos; Sule, Umar Musa; Ahmad, Abdurrahman; Atiku, Mamuda; Mohammed, Alhassan Datti; Sarki, Adamu Muhammad; Adekola, Oyebola; Akanmu, Olanrewaju; Durodola, Adekunle; Olukoju, Olusegun; Raji, Victor; Olajumoke, Tokunbo; Oyebamiji, Emmanuel; Adenekan, Anthony; Adetoye, Adedapo; Faponle, Folayemi; Olateju, Simeon; Owojuyigbe, Afolabi; Talabi, Ademola; Adenike, Odewabi; Adewale, Badru; Collins, Nwokoro; Ezekiel, Emmanuel; Fatungase, Oluwabunmi Motunrayo; Grace, Anuforo; Sola, Sotannde; Stella, Ogunmuyiwa; Ademola, Adeyinka; Adeolu, Augustine A.; Adigun, Tinuola; Akinwale, Mukaila; Fasina, Oluyemi; Gbolahan, Olalere; Idowu, Olusola; Olonisakin, Rotimi Peter; Osinaike, Babatunde Babasola; Asudo, Felicia; Mshelia, Danladi; Abdur-Rahman, Lukman; Agodirin, Olayide; Bello, Jibril; Bolaji, Benjamin; Oyedepo, Olanrewaju Olubukola; Ezike, Humphrey; Iloabachie, Ikechukwu; Okonkwo, Ikemefuna; Onuora, Elias; Onyeka, Tonia; Ugwu, Innocent; Umeh, Friday; Alagbe-Briggs, Olubusola; Dodiyi-Manuel, Amabra; Echem, Richard; Obasuyi, Bright; Onajin-Obembe, Bisola; Bandeira, Maria Expedito; Martins, Alda; Tomé, Miguel; Costa, Ana Cristina Miranda Martins; Krystopchuk, Andriy; Branco, Teresa; Esteves, Simao; Melo, Marco António; Monte, Júlia; Rua, Fernando; Martins, Isabel; Pinho-Oliveira, Vítor Miguel; Rodrigues, Carla Maria; Cabral, Raquel; Marques, Sofia; Rêgo, Sara; Jesus, Joana Sofia Teixeira; Marques, Maria Conceição; Romao, Cristina; Dias, Sandra; Santos, Ana Margarida; Alves, Maria Joao; Salta, Cristina; Cruz, Salome; Duarte, Célia; Paiva, António Armando Furtado; Cabral, Tiago do Nascimento; Faria E Maia, Dionisio; Correia da Silva, Rui Freitas Mendonça; Langner, Anuschka; Resendes, Hernâni Oliveira; Soares, Maria da Conceição; Abrunhosa, Alexandra; Faria, Filomena; Miranda, Lina; Pereira, Helena; Serra, Sofia; Ionescu, Daniela; Margarit, Simona; Mitre, Calin; Vasian, Horatiu; Manga, Gratiela; Stefan, Andreea; Tomescu, Dana; Filipescu, Daniela; Paunescu, Marilena-Alina; Stefan, Mihai; Stoica, Radu; Gavril, Laura; Pătrășcanu, Emilia; Ristescu, Irina; Rusu, Daniel; Diaconescu, Ciresica; Iosep, Gabriel Florin; Pulbere, Dorin; Ursu, Irina; Balanescu, Andreea; Grintescu, Ioana; Mirea, Liliana; Rentea, Irina; Vartic, Mihaela; Lupu, Mary-Nicoleta; Stanescu, Dorin; Streanga, Lavinea; Antal, Oana; Hagau, Natalia; Patras, Dumitru; Petrisor, Cristina; Tosa, Flaviu; Tranca, Sebastian; Copotoiu, Sanda Maria; Ungureanu, Liviu Lucian; Harsan, Cristian Remus; Papurica, Marius; Cernea, Daniela Denisa; Dragoescu, Nicoleta Alice; CarmenVaida, Laura Aflori; Ciobotaru, Oana Roxana; Aignatoaie, Mariana; Carp, Cristina Paula; Cobzaru, Isabelle; Mardare, Oana; Purcarin, Bianca; Tutunaru, Valentin; Ionita, Victor; Arustei, Mirela; Codita, Anisoara; Busuioc, Mihai; Chilinciuc, Ion; Ciobanu, Cristina; Belciu, Ioana; Tincu, Eugen; Blaj, Mihaela; Grosu, Ramona-Mihaela; Sandu, Gigel; Bruma, Dana; Corneci, Dan; Dutu, Madalina; Krepil, Adriana; Copaciu, Elena; Dumitrascu, Clementina Oana; Jemna, Ramona; Mihaescu, Florentina; Petre, Raluca; Tudor, Cristina; Ursache, Elena; Kulikov, Alexander; Lubnin, Andrey; Grigoryev, Evgeny; Pugachev, Stanislav; Tolmasov, Alexander; Hussain, Ayyaz; Ilyina, Yana; Roshchina, Anna; Iurin, Aleksandr; Chazova, Elena; Dunay, Artem; Karelov, Alexey; Khvedelidze, Irina; Voldaeva, Olga; Belskiy, Vladislav; Dzhamullaev, Parvin; Grishkowez, Elena; Kretov, Vladimir; Levin, Valeriy; Molkov, Aleksandr; Puzanov, Sergey; Samoilenko, Aleksandr; Tchekulaev, Aleksandr; Tulupova, Valentina; Utkin, Ivan; Allorto, Nikki Leigh; Bishop, David Gray; Builu, Pierre Monji; Cairns, Carel; Dasrath, Ashish; de Wet, Jacques; Hoedt, Marielle den; Grey, Ben; Hayes, Morgan Philip; Küsel, Belinda Senta; Shangase, Nomcebo; Wise, Robert; Cacala, Sharon; Farina, Zane; Govindasamy, Vishendran; Kruse, Carl-Heinz; Lee, Carolyn; Marais, Leonard; Naidoo, Thinagrin Dhasarthun; Rajah, Chantal; Rodseth, Reitze Nils; Ryan, Lisa; von Rhaden, Richard; Adam, Suwayba; Alphonsus, Christella; Ameer, Yusuf; Anderson, Frank; Basanth, Sujith; Bechan, Sudha; Bhula, Chettan; Biccard, Bruce M.; Biyase, Thuli; Buccimazza, Ines; Cardosa, Jorge; Chen, James; Daya, Bhavika; Drummond, Leanne; Elabib, Ali; Abdel Goad, Ehab Helmy; Goga, Ismail E.; Goga, Riaz; Harrichandparsad, R.; Hodgson, Richard E.; Jordaan, J.; Kalafatis, Nicky; Kampik, Christian; Landers, A. T.; Loots, Emil; Madansein, Rajhmum; Madaree, Anil; Madiba, Thandinkosi E.; Manzini, Vukani T.; Mbuyisa, Mbali; Moodley, Rajan; Msomi, Mduduzi; Mukama, Innocent; Naidoo, Desigan; Naidoo, Rubeshan; Naidu, Tesuven K.; Ntloko, Sindiswa; Padayachee, Eneshia; Padayachee, Lucelle; Phaff, Martijn; Pillay, Bala; Pillay, Desigan; Pillay, Lutchmee; Ramnarain, Anupa; Ramphal, Suren R.; Ryan, Paul; Saloojee, Ahmed; Sebitloane, Motshedisi; Sigcu, Noluyolo; Taylor, Jenna L.; Torborg, Alexandra; Visser, Linda; Anderson, Philip; Conradie, Alae; de Swardt, Mathew; de Villiers, Martin; Eikman, Johan; Liebenberg, Riaan; Mouton, Johan; Paton, Abbey; van der Merwe, Louwrence; Wilscott-Davids, Candice; Barrett, Wendy Joan; Bester, Marlet; de Beer, Johan; Geldenhuys, Jacques; Gouws, Hanni; Potgieter, Jan-Hendrik; Strydom, Magdel; WilberforceTurton, Edwin; Chetty, Rubendraj R.; Chirkut, Subash; Cronje, Larissa; de Vasconcellos, Kim; Dube, Nokukhanya Z.; Gama, N. Sibusiso; Green, Garyth M.; Green-Thompson, Randolph; Kinoo, Suman Mewa; Kistnasami, Prenolin; Maharaj, Kapil; Moodley, Manogaran S.; Mothae, Sibongile J.; Naidoo, Ruvashni; Aslam F Noorbhai, M.; Rughubar, Vivesh; Reddy, Jenendhiran; Singh, Avesh; Skinner, David L.; Smith, Murray J.; Singh, Bhagwan; Misra, Ravi; Naidoo, Maheshwar; Ramdharee, Pireshin; Selibea, Yvonne; Sewpersad, Selina; Sham, Shailendra; Wessels, Joseph D.; Africander, Cucu; Bejia, Tarek; Blakemore, Stephen P.; Botes, Marisa; Bunwarie, Bimalshakth; Hernandez, Carlos B.; Jeeraz, Mohammud A.; Legutko, Dagmara A.; Lopez, Acela G.; de Meyer, Jenine N.; Muzenda, Tanaka; Naidoo, Noel; Patel, Maryam; Pentela, Rao; Junge, Marina; Mansoor, Naj; Rademan, Lana; Scislowski, Pawel; Seedat, Ismail; van den Berg, Bianca; van der Merwe, Doreen; van Wyk, Steyn; Govender, Komalan; Naicker, Darshan; Ramjee, Rajesh; Saley, Mueen; Kuhn, Warren Paul; Matos-Puig, Roel; Alberto Lisi, Zaheer Moolla; Perez, Gisela; Beltran, Anna Valle; Lozano, Angels; Navarro, Carlos Delgado; Duca, Alejandro; Ernesto, Ernesto Pastor Martinez; Ferrando, Carlos; Fuentes, Isabel; García-Pérez, Maria Luisa; Gracia, Estefania; Palomares, Ana Izquierdo; Katime, Antonio; Miñana, Amanda; Incertis, Raul Raul; Romero, Esther; Romero Garcia, Carolina Soledad; Rubio, Concepcion; Artiles, Tania Socorro; Soro, Marina; Valls, Paola; Laguarda, Gisela Alaman; Benavent, Pau; Cuenca, Vicente Chisbert; Cueva, Andreu; Lafuente, Matilde; Parra, Asuncion Marques; Rodrigo, Alejandra Romero; Sanchez-Morcillo, Silvia; Tormo, Sergi; Redondo, Francisco Javier; de Andrés Ibanez, José Antonio; Diago, Lorena Gómez; José Hernández Cádiz, Maria; Manuel, Granell Gil; Peris, Raquel; Saiz, Cristina; Vivo, Jose Tatay; Soto, Maria Teresa Tebar; Brunete, Tamara; Cancho, David; Delgado García, David R.; Zamudio, Diana; del Valle, Santiago Garcia; Serrano, M. Luz; Alonso, Eduardo; Anillo, Victor; Maseda, Emilio; Salgado, Patricia; Suarez, Luis; Suarez-de-la-Rica, Alejandro; Villagrán, María José; Alonso, José Ignacio; Cabezuelo, Estefania; Garcia-Saiz, Irene; Lopez del Moral, Olga; Martín, Silvia; Gonzalez, Alba Perez; Doncel, Ma Sherezade Tovar; Vera, Martin Agüero; José Ávila Sánchez, Francisco; Castaño, Beatriz; Moreira, Beatriz Castaño; Risco, Sahely Flores; Martín, Daniel Paz; Martín, Fernando Pérez; Poza, Paloma; Ruiz, Adela; Serna Martínez, Wilson Fabio; Vicente, Bárbara Vázquez; Dominguez, Saul Velaz; Fernández, Salvador; Munoz-López, Alfonso; Bernat, Maria Jose; Mas, Arantxa; Planas, Kenneth; Jawad, Monir; Saeed, Yousif; Hedin, Annika; Levander, Helena; Holmström, Sandra; Lönn, David; Zoerner, Frank; Åkring, Irene; Widmark, Carl; Zettergren, Jan; Liljequist, Victor Aspelund; Nystrom, Lena; Odeberg-Wernerman, Suzanne; Oldner, Anders; Fagerlund, Malin Jonsson; Reje, Patrik; Lyckner, Sara; Sperber, Jesper; Adolfsson, Anne; Klarin, Bengt; Ögren, Katrin; Barras, Jean-Pierre; Bührer, Thomas; Despotidis, Vasileios; Helmy, Naeder; Holliger, Stephan; Raptis, Dimitri Aristotle; Schmid, Roger; Meyer, Antoine; Jaquet, Yves; Kessler, Ulf; Muradbegovic, Mirza; Nahum, Solange R.; Rotunno, Teresa; Schiltz, Boris; Voruz, François; Worreth, Marc; Christoforidis, Dimitri; Popeskou, Sotirios Georgios; Furrer, Markus; Prevost, Gian Andrea; Stocker, Andrea; Lang, Klaus; Breitenstein, Stefan; Ganter, Michael T.; Geisen, Martin; Soll, Christopher; Korkmaz, Michelle; Lubach, Iris; Schmitz, Michael; Meyer Zu Schwabedissen, Moritz; Moritz, Meyer Zu Schwabedissen; Zingg, Urs; Hillermann, Thomas; Wildi, Stefan; Pinto, Bernardo Bollen; Walder, Bernhard; Mariotti, Giustina; Slankamenac, Ksenija; Namuyuga, Mirioce; Kyomugisha, Edward; Kituuka, Olivia; Shikanda, Anne Wesonga; Kakembo, Nasser; Tom, Charles Otim; Antonina, Webombesa; Bua, Emmanuel; Ssettabi, Eden Michael; Epodoi, Joseph; Kabagenyi, Fiona; Kirya, Fred; Dempsey, Ged; Seasman, Colette; Nawaz Khan, Raja Basit; Kurasz, Claire; Macgregor, Mark; Shawki, Burhan; Francis, Daren; Hariharan, Vimal; Chau, Simon; Ellis, Kate; Butt, Georgina; Chicken, Dennis-Wayne; Christmas, Natasha; Allen, Samantha; Daniel, Gayatri Daniel; Dempster, Angie; Kemp, Juliette; Matthews, Lewis; Mcglone, Philip; Tambellini, Joanne; Trodd, Dawn; Freitas, Katie; Garg, Atul; Gupta, Janesh Kumar; Karpate, Shilpaja; Kulkarni, Aditi; O'Hara, Chloe; Troko, Jtroko; Angus, Kirsty; Bradley, Jacqueline; Brennan, Emma; Brooks, Carolyn; Brown, Janette; Brown, Gemma; Finch, Amanda; Gratrix, Karen; Hesketh, Sue; Hill, Gillian; Jeffs, Carol; Morgan, Maureen; Pemberton, Chris; Slawson, Nicola; Spickett, Helen; Swarbrick, Gemma; Thomas, Megan; van Duyvenvoorde, Greta; Brennan, Andrew; Briscoe, Richard; Cooper, Sarah; Lawton, Tom; Northey, Martin; Senaratne, Rashmi; Stanworth, Helen; Burrows, Lorna; Cain, Helen; Craven, Rachael; Davies, Keith; Jonas, Attila; Pachucki, Marcin; Walkden, Graham; Davies, Helen; Gudaca, Mariethel; Hobrok, Maria; Arawwawala, Dilshan; Fergey, Lauren; Gardiner, Matthew; Gunn, Jacqueline; Johnson, Lyndsay; Lofting, Amanda; Lyle, Amanda; Neela, Fiona Mc; Smolen, Susan; Topliffe, Joanne; Williams, Sarah; Bland, Martin; Balaji, Packianathaswamy; Kaura, Vikas; Lanka, Prasad; Smith, Neil; Ahmed, Ahmed; Myatt, John; Shenoy, Ravikiran; Soon, Wai Cheong; Tan, Jessica; Karadia, Sunny; Self, James; Durant, Emma; Tripathi, Shiva; Bullock, Clare; Campbell, Debbie; Ghosh, Alison; Hughes, Thomas; Zsisku, Lajos; Bengeri, Sheshagiri; Cowton, Amanda; Khalid, Mohammed Shazad; Limb, James; McAdam, Colin; Porritt, Mandy; Rafi, M. Amir; Shekar, Priya; Adams, David; Harden, Catherine; Hollands, Heidi; King, Angela; March, Linda; Minto, Gary; Patrick, Abigail; Squire, Rosalyn; Waugh, Darren; Kumara, Paramesh; Simeson, Karen; Yarwood, Jamie; Browning, Julie; Hatton, Jonathan; Julian, Howes; Mitra, Atideb; Newton, Maria; Pernu, Pawan Kootelu; Wilson, Alison; Commey, Thelma; Foot, Helen; Glover, Lyn; Gupta, Ajay; Lancaster, Nicola; Levin, Jill; Mackenzie, Felicity; Mestanza, Claire; Nofal, Emma; Pout, Lauren; Varden, Rosanna; Wild, Jonathan; Jones, Stephanie; Moreton, Sarah; Pulletz, Mark; Davies, Charlotte; Martin, Matthew; Thomas, Sian; Burns, Karen; McArthur, Carol; Patel, Panna; Lau, Gary; Rich, Natalie; Davis, Fiona; Lyons, Rachel; Port, Beth; Prout, Rachel; Smith, Christopher; Adelaja, Yemi; Bennett, Victoria; Bidd, Heena; Dumitrescu, Alexandra; Murphy, Jacqui Fox; Keen, Abigail; Mguni, Nhlanhla; Ong, Cheng; Adams, George; Boshier, Piers; Brown, Richard; Butryn, Izabella; Chatterjee, Jayanta; Freethy, Alexander; Lockwood, Geoffrey; Tsakok, Maria; Tsiligiannis, Sophia; Peat, William; Stephenson, Lorraine; Bradburn, Mike; Pick, Sara; Cunha, Pedro; Olagbaiye, Olufemi; Tayeh, Salim; Packianathaswamy, Balaji; Abernethy, Caroline; Balasubramaniam, Madhu; Bennett, Rachael; Bolton, David; Martinson, Victoria; Naylor, Charde; Bell, Stephanie; Heather, Blaylock; Kushakovsky, Vlad; Alcock, Liam; Alexander, Hazel; Anderson, Colette; Baker, Paul; Brookes, Morag; Cawthorn, Louise; Cirstea, Emanuel; Clarkson, Rachel; Colling, Kerry; Coulter, Ian; Das, Suparna; Haigh, Kathryn; Hamdan, Alhafidz; Hugill, Keith; Kottam, Lucksy; Lisseter, Emily; Mawdsley, Matthew; McGivern, Julie; Padala, Krishnaveni; Phelps, Victoria; Ramesh Kumar, Vineshykaa; Stewart, Kirsten; Towse, Kayley; Tregonning, Julie; Vahedi, Ali; Walker, Alycon; Baines, Duncan; Bilolikar, Anjali; Chande, Shiv; Copley, Edward; Dunk, Nigel; Kulkarni, Raghavendra; Kumar, Pawan; Metodiev, Yavor; Ncomanzi, Dumisani; Raithatha, Bhavesh; Raymode, Parizade; Szafranski, Jan; Twohey, Linda; Watt, Philip; Weatherall, Lucie; Weatherill, J.; Whitman, Zoe; Wighton, Elinor; Abayasinghe, Chamika; Chan, Alexander; Darwish, Sharif; Gill, James; Glasgow, Emma; Hadfield, Daniel; Harris, Clair; Hopkins, Phil; Kochhar, Arun; Kunst, Gudrun; Mellis, Clare; Pool, Andrew; Riozzi, Paul; Selman, Andrew; Smith, Emma-Jane; Vele, Liana; Gercek, Yuksel; Guy, Kramer; Holden, Douglas; Watson, Nicholas; Whysall, Karen; Andreou, Prematie; Hales, Dawn; Thompson, Jonathan; Bowrey, Sarah; McDonald, Shara; Gilmore, Jemma; Hills, Vicky; Kelly, Chan; Kelly, Sinead; Lloyd, Geraint; Abbott, Tom; Gall, Lewis; Torrance, Hew; Vivian, Mark; Berntsen, Emer; Nolan, Tracey; Turner, Angus; Vohra, Akbar; Brown, Andrew; Clark, Richard; Coughlan, Elaine; Daniel, Conway; Patvardhan, Chinmay; Pearson, Rachel; Predeep, Sheba; Saad, Hesham; Shanmugam, Mohanakrishnan; Varley, Simon; Wylie, Katharine; Cooper, Lucy; Makowski, Arystarch; Misztal, Beata; Moldovan, Eliza; Pegg, Claire; Donovan, Andrew; Foot, Jayne; Large, Simon; Claxton, Andrew; Netke, Bhagyashree; Armstrong, Richard; Calderwood, Claire; Kwok, Andy; Mohr, Otto; Oyeniyi, Peter; Patnaik, Lisa; Post, Benjamin; Ali, Sarah; Arshad, Homa; Baker, Gerard; Brenner, Laura; Brincat, Maximilian; Brunswicker, Annemarie; Cox, Hannah; Cozar, Octavian Ionut; Cheong, Edward; Durst, Alexander; Fengas, Lior; Flatt, Jim; Glister, Georgina; Narwani, Vishal; Photi, Evangelos; Rankin, Adeline; Rosbergen, Melissa; Tan, Mark; Beaton, Ceri; Horn, Rachel; Hunt, Jane; Rousseau, Guy; Stancombe, Lucia; Absar, Mohammed; Allsop, Joanne; Drinkwater, Zoe; Hodgkiss, Tracey; Smith, Kirsty; Brown, Jamie; Alexander-Sefre, Farhad; Campey, Lorraine; Dudgeon, Lucy; Hall, Kathryn; Hitchcock, Rachael; James, Lynne; Smith, Kate; Winstone, Ulrika; Ahmad, Norfaizan; Bauchmuller, Kris; Harrison, Jonathan; Jeffery, Holly; Miller, Duncan; Pinder, Angela; Pothuneedi, Sailaja; Rosser, Jonathan; Sanghera, Sumayer; Swift, Diane; Walker, Rachel; Bester, Delia; Cavanagh, Sarah; Cripps, Heather; Daniel, Harvey; Lynch, Julie; Paton, Alison; Pyke, Shirley; Scholefield, John; Whitworth, Helen; Bottrill, Fiona; Ramalingam, Ganesh; Webb, Stephen; Akerman, Nik; Antill, Philip; Bourner, Lynsey; Buckley, Sarah; Castle, Gail; Charles, Rob; Eggleston, Christopher; Foster, Rebecca; Gill, Satwant; Lindley, Kate; Lklouk, Mohamed; Lowery, Tracey; Martin, Oliver; Milne, David; O'Connor, Patrick; Ratcliffe, Andrew; Rose, Alastair; Smith, Annie; Varma, Sandeep; Ward, Jackie; Barcraft-Barnes, Helena; Camsooksai, Julie; Colvin, Carolyn; Reschreiter, Henrik; Tbaily, Lee; Venner, Nicola; Hamilton, Caroline; Kelly, Lewis; Toth-Tarsoly, Piroska; Dodsworth, Kerry; Foord, Denise; Gordon, Paul; Hawes, Elizabeth; Lamb, Nikki; Mouland, Johanna; Nightingale, Jeremy; Rose, Steve; Schrieber, Joe; Al'Amri, Khalid; Aladin, Hafiz; Arshad, Mohammed Asif; Barraclough, James; Bentley, Conor; Bergin, Colin; Carrera, Ronald; Clarkson, Aisling; Collins, Michelle; Cooper, Lauren; Denham, Samuel; Griffiths, Ewen; Ip, Peter; Jeyanthan, Somasundaram; Joory, Kavita; Kaur, Satwant; Marriott, Paul; Mitchell, Natalie; Nagaiah, Sukumar; Nilsson, Annette; Parekh, Nilesh; Pope, Martin; Seager, Joseph; Serag, Hosam; Tameem, Alifia; Thomas, Anna; Thunder, Joanne; Torrance, Andrew; Vohra, Ravinder; Whitehouse, Arlo; Wong, Tony; Blunt, Mark; Wong, Kate; Giles, Julian; Reed, Isabelle; Weller, Debbie; Bell, Gillian; Birch, Julie; Damant, Rose; Maiden, Jane; Mewies, Clare; Prince, Claire; Radford, Jane; Reynolds, Tim; Balain, Birender; Banerjee, Robin; Barnett, Andrew; Burston, Ben; Davies, Kirsty; Edwards, Jayne; Evans, Chris; Ford, David; Gallacher, Pete; Hill, Simon; Jaffray, David; Karlakki, Sudheer; Kelly, Cormac; Kennedy, Julia; Kiely, Nigel; Lewthwaite, Simon; Marquis, Chris; Ockendon, Matthew; Phillips, Stephen; Pickard, Simon; Richardson, James; Roach, Richard; Smith, Tony; Spencer-Jones, Richard; Steele, Niall; Steen, Julie; van Liefland, Marck; White, Steve; Faulds, Matthew; Harris, Meredyth; Kelly, Carrie; Nicol, Scott; Pearson, Sally Anne; Chukkambotla, Srikanth; Andrew, Alyson; Attrill, Elizabeth; Campbell, Graham; Datson, Amanda; Fouracres, Anna; Graterol, Juan; Graves, Lynne; Hong, Bosun; Ishimaru, Alexander; Karthikeyan, Arvind; King, Helen; Lawson, Tom; Lee, Gregory; Lyons, Saoirse; Hall, Andrew Macalister; Mathoulin, Sophie; Mcintyre, Eilidh; Mclaughlin, Danny; Mulcahy, Kathleen; Paddle, Jonathan; Ratcliffe, Anna; Robbins, James; Sung, Weilin; Tayo, Adeoluwa; Trembath, Lisa; Venugopal, Suneetha; Walker, Robert; Wigmore, Geoffrey; Boereboom, Catherine; Downes, Charlotte; Humphries, Ryan; Melbourne, Susan; Smith, Coral; Tou, Samson; Ullah, Shafa; Batchelor, Nick; Boxall, Leigh; Broomby, Rupert; Deen, Tariq; Hellewell, Alistair; Helliwell, Laurence; Hutchings, Melanie; Hutchins, David; Keenan, Samantha; Mackie, Donna; Potter, Alison; Smith, Frances; Stone, Lucy; Thorpe, Kevin; Wassall, Richard; Woodgate, Andrew; Baillie, Shelley; Campbell, Tara; James, Sarah; King, Chris; Marques de Araujo, Daniela; Martin, Daniel; Morkane, Clare; Neely, Julia; Rajendram, Rajkumar; Burton, Megan; James, Kathryn; Keevil, Edward; Minik, Orsolya; Morgan, Jenna; Musgrave, Anna; Rajanna, Harish; Roberts, Tracey; Adamson, Michael; Jumbe, Sandra; Kendall, Jennie; Muthuswamy, Mohan Babu; Anderson, Charlotte; Cruikshanks, Andrew; Wrench, Ian; Zeidan, Lisa; Ardern, Diane; Harris, Benjamin; Hellstrom, Johanna; Martin, Jane; Thomas, Richard; Varsani, Nimu; Brown, Caroline Wrey; Docherty, Philip; Gillies, Michael; McGregor, Euan; Usher, Helen; Craig, Jayne; Smith, Andrew; Ahmad, Tahania; Bodger, Phoebe; Creary, Thais; Fowler, Alexander; Hewson, Russ; Ijuo, Eke; Jones, Timothy; Kantsedikas, Ilya; Lahiri, Sumitra; McLean, Aaron Lawson; Niebrzegowska, Edyta; Phull, Mandeep; Wang, Difei; Wickboldt, Nadine; Baldwin, Jacqueline; Doyle, Donna; Mcmullan, Sean; Oladapo, Michelle; Owen, Thomas; Williams, Alexandra; Daniel, Hull; Gregory, Peter; Husain, Tauqeer; Kirk-Bayley, Justin; Mathers, Edward; Montague, Laura; Harper, Mark; White, Stuart; Jack, James; Ridley, Carrie; Avis, Joanne; Cook, Tim; Dali-Kemmery, Lola; Kerslake, Ian; Lambourne, Victoria; Pearson, Annabel; Boyd, Christine; Callaghan, Mark; Lawson, Cathy; McCrossan, Roopa; Nesbitt, Vanessa; O'connor, Laura; Scott, Julia; Sinclair, Rhona; Farid, Nahla; Morgese, Ciro; Bhatia, Kailash; Karmarkar, Swati; Ahmed, Jamil; Branagan, Graham; Hutton, Monica; Swain, Andrew; Brookes, Jamie; Cornell, Jonathan; Dolan, Rachael; Hulme, Jonathan; Jansen van Vuuren, Amanda; Jowitt, Tom; Kalashetty, Gunasheela; Lloyd, Fran; Patel, Kiran; Sherwood, Nicholas; Brown, Lynne; Chandler, Ben; Deighton, Kerry; Emma, Temlett; Haunch, Kirsty; Cheeseman, Michelle; Dent, Kathy; Garg, Sanjeev; Gray, Carol; Hood, Marion; Jones, Dawn; Juj, Joanne; Rao, Roshan; Walker, Tara; Al Anizi, Mashel; Cheah, Clarissa; Cheing, Yushio; Coutinho, Francisco; Gondo, Prisca; Hadebe, Bernard; Hove, Mazvangu Onie; Khader, Ahamed; Krishnachetty, Bobby; Rhodes, Karen; Sokhi, Jagdish; Baker, Katie-Anne; Bertram, Wendy; Looseley, Alex; Mouton, Ronelle; Hanna, George; Arnold, Glenn; Arya, Shobhit; Balfoussia, Danai; Baxter, Linden; Harris, James; Jones, Craig; Knaggs, Alison; Markar, Sheraz; Perera, Anisha; Scott, Alasdair; Shida, Asako; Sirha, Ravneet; Wright, Sally; Frost, Victoria; Gray, Catherine; Andrews, Emma; Arrandale, Lindsay; Barrett, Stephen; Cifra, Elna; Cooper, Mariese; Dragnea, Dragos; Elna, Cifra; Maclean, Jennifer; Meier, Sonja; Milliken, Donald; Munns, Christopher; Ratanshi, Nadir; Ramessur, Suneil; Salvana, Abegail; Watson, Anthony; Ali, Hani; Campbell, Gill; Critchley, Rebecca; Endersby, Simon; Hicks, Catherine; Liddle, Alison; Pass, Marc; Ritchie, Charlotte; Thomas, Charlotte; Too, Lingxi; Welsh, Sarah; Gill, Talvinder; Johnson, Joanne; Reed, Joanne; Davis, Edward; Papadopoullos, Sam; Attwood, Clare; Biffen, Andrew; Boulton, Kerenza; Gray, Sophie; Hay, David; Mills, Sarah; Montgomery, Jane; Riddell, Rory; Simpson, James; Bhardwaj, Neeraj; Paul, Elaine; Uwubamwen, Nosakhare; Alexander, Maini; Arrich, James; Arumugam, Swarna; Blackwood, Douglas; Boggiano, Victoria; Brown, Robyn; Chan, Yik Lam; Chatterjee, Devnandan; Chhabra, Ashok; Christian, Rachel; Costelloe, Hannah; Matthewman, Madeline Coxwell; Dalton, Emma; Darko, Julia; Davari, Maria; Dave, Tejal; Deacon, Matthew; Deepak, Shantal; Edmond, Holly; Ellis, Jessica; El-Sayed, Ahmed; Eneje, Philip; English, Rose; Ewe, Renee; Foers, William; Franklin, John; Gallego, Laura; Garrett, Emily; Goldberg, Olivia; Goss, Harry; Greaves, Rosanna; Harris, Rudy; Hennings, Charles; Jones, Eleanor; Kamali, Nelson; Kokkinos, Naomi; Lewis, Carys; Lignos, Leda; Malgapo, Evaleen Victoria; Malik, Rizwana; Milne, Andrew; Mulligan, John-Patrick; Nicklin, Philippa; Palipane, Natasha; Parsons, Thomas; Piper, Rebecca; Prakash, Rohan; Ramesh, Byron; Rasip, Sarah; Reading, Jacob; Rela, Mariam; Reyes, Anna; Stephens, Robert; Rooms, Martin; Shah, Karishma; Simons, Henry; Solanki, Shalil; Spowart, Emma; Stevens, Amy; Thomas, Christopher; Waggett, Helena; Yassaee, Arrash; Kennedy, Anthony; Scott, Sara; Somanath, Sameer; Berg, Andrew; Hernandez, Miguel; Nanda, Rajesh; Tank, Ghanshyambhai; Wilson, Natalie; Wilson, Debbie; Al-Soudaine, Yassr; Baldwin, Matthew; Cornish, Julie; Davies, Zoe; Davies, Leigh; Edwards, Marc; Frewer, Natasha; Gallard, Sian; Glasbey, James; Harries, Rhiannon; Hopkins, Luke; Kim, Taeyang; Koompirochana, Vilavan; Lawson, Simon; Lewis, Megan; Makzal, Zaid; Scourfield, Sarah; Ahmad, Yousra; Bates, Sarah; Blackwell, Clare; Bryant, Helen; Collins, Hannah; Coulter, Suzanne; Cruickshank, Ross; Daniel, Sonya; Daubeny, Thomas; Edwards, Mark; Golder, Kim; Hawkins, Lesley; Helen, Bryant; Hinxman, Honor; Levett, Denny; Salmon, Karen; Seaward, Leanne; Skinner, Ben; Tyrell, Bryony; Wadams, Beverley; Walsgrove, Joseph; Dickson, Jane; Constantin, Kathryn; Karen, Markwell; O'Brien, Peter; O'Donohoe, Lynn; Payne, Hannah; Sundayi, Saul; Walker, Elaine; Brooke, Jenny; Cardy, Jon; Humphreys, Sally; Kessack, Laura; Kubitzek, Christiane; Kumar, Suhas; Cotterill, Donna; Hodzovic, Emil; Hosdurga, Gurunath; Miles, Edward; Saunders, Glenn; Campbell, Marta; Chan, Peter; Jemmett, Kim; Raj, Ashok; Naik, Aditi; Oshowo, Ayo; Ramamoorthy, Rajarajan; Shah, Nimesh; Sylvan, Axel; Blyth, Katharine; Burtenshaw, Andrew; Freeman, David; Johnson, Emily; Lo, Philip; Martin, Terry; Plunkett, Emma; Wollaston, Julie; Allison, Joanna; Carroll, Christine; Craw, Nicholas; Craw, Sarah; Pitt-Kerby, Tressy; Rowland-Axe, Rebecca; Spurdle, Katie; McDonald, Andrew; Simon, Davies; Sinha, Vivek; Smith, Thomas; Banner-Goodspeed, Valerie; Boone, Myles; Campbell, Kathleen; Lu, Fengxin; Scannell, Joseph; Sobol, Julia; Balajonda, Naraida; Clemmons, Karen; Conde, Carlos; Elgasim, Magdi; Funk, Bonita; Hall, Roger; Hopkins, Thomas; Olaleye, Omowunmi; Omer, Omer; Pender, Michelle; Porto, Angelo; Stevens, Alice; Waweru, Peter; Yeh, Erlinda; Bodansky, Daniella; Evans, Adam; Kleopoulos, Steven; Maril, Robert; Mathney, Edward; Sanchez, Angela; Tinuoye, Elizabeth; Bateman, Brian; Eng, Kristen; Jiang, Ning; Ladha, Karim; Needleman, Joseph; Chen, Lee-Lynn; Lane, Rondall; Robinowitz, David; Ghushe, Neil; Irshad, Mariam; O'Connor, John; Patel, Samir; Takemoto, Steven; Wallace, Art; Mazzeffi, Michael; Rock, Peter; Wallace, Karin; Zhu, Xiaomao; Chua, Pandora; Mattera, Matthew; Sharar, Rebecca; Thilen, Stephan; Treggiari, Miriam; Morgan, Angela; Sofjan, Iwan; Subramaniam, Kathirvel; Avidan, Michael; Maybrier, Hannah; Muench, Maxwell; Wildes, Troy

    2018-01-01

    The surgical safety checklist is widely used to improve the quality of perioperative care. However, clinicians continue to debate the clinical effectiveness of this tool. Prospective analysis of data from the International Surgical Outcomes Study (ISOS), an international observational study of

  16. Safety and Effectiveness of Vibration Massage by Deep Oscillations: A Prospective Observational Study

    Directory of Open Access Journals (Sweden)

    Karin Kraft

    2013-01-01

    Full Text Available The objective of this study is to assess the safety of treatment with vibration massage using a deep oscillation device and the effects on symptom severity and quality of life in patients with primary fibromyalgia syndrome (FMS. Outpatients with FMS performed an observational prospective study with visits 2–4 weeks after the last treatment (control and after further 2 months (follow-up. Patients were treated with 10 sessions of 45 min deep oscillation massage, 2/week. Primary outcome parameters were safety and tolerability (5-level Likert scale (1 = very good (after each treatment session and at control visit. Secondary outcome parameters were symptom severity (Fibromyalgia Impact Questionnaire (FIQ, pain and quality of life (SF-36. Seventy patients (97.1% females were included. At control visit, 41 patients (58.6% reported 63 mild and short-lasting adverse events, mainly worsening of prevalent symptoms such as pain and fatigue. Tolerability was rated as 1.8 (95% confidence interval: 1.53; 2.07. Symptoms and quality of life were significantly improved at both control and follow-up visits (at least P<0.01. In conclusion, deep oscillation massage is safe and well tolerated in patients with FMS and might improve symptoms and quality of life rather sustained.

  17. Applications of Dynamic Clamp to Cardiac Arrhythmia Research: Role in Drug Target Discovery and Safety Pharmacology Testing

    Directory of Open Access Journals (Sweden)

    Francis A. Ortega

    2018-01-01

    Full Text Available Dynamic clamp, a hybrid-computational-experimental technique that has been used to elucidate ionic mechanisms underlying cardiac electrophysiology, is emerging as a promising tool in the discovery of potential anti-arrhythmic targets and in pharmacological safety testing. Through the injection of computationally simulated conductances into isolated cardiomyocytes in a real-time continuous loop, dynamic clamp has greatly expanded the capabilities of patch clamp outside traditional static voltage and current protocols. Recent applications include fine manipulation of injected artificial conductances to identify promising drug targets in the prevention of arrhythmia and the direct testing of model-based hypotheses. Furthermore, dynamic clamp has been used to enhance existing experimental models by addressing their intrinsic limitations, which increased predictive power in identifying pro-arrhythmic pharmacological compounds. Here, we review the recent advances of the dynamic clamp technique in cardiac electrophysiology with a focus on its future role in the development of safety testing and discovery of anti-arrhythmic drugs.

  18. Testing the effects of safety climate and disruptive children behavior on school bus drivers performance: A multilevel model.

    Science.gov (United States)

    Zohar, Dov; Lee, Jin

    2016-10-01

    The study was designed to test a multilevel path model whose variables exert opposing effects on school bus drivers' performance. Whereas departmental safety climate was expected to improve driving safety, the opposite was true for in-vehicle disruptive children behavior. The driving safety path in this model consists of increasing risk-taking practices starting with safety shortcuts leading to rule violations and to near-miss events. The study used a sample of 474 school bus drivers in rural areas, driving children to school and school-related activities. Newly developed scales for measuring predictor, mediator and outcome variables were validated with video data taken from inner and outer cameras, which were installed in 29 buses. Results partially supported the model by indicating that group-level safety climate and individual-level children distraction exerted opposite effects on the driving safety path. Furthermore, as hypothesized, children disruption moderated the strength of the safety rule violation-near miss relationship, resulting in greater strength under high disruptiveness. At the same time, the hypothesized interaction between the two predictor variables was not supported. Theoretical and practical implications for studying safety climate in general and distracted driving in particular for professional drivers are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Very high temperature measurements: Applications to nuclear reactor safety tests

    International Nuclear Information System (INIS)

    Parga, Clemente-Jose

    2013-01-01

    This PhD dissertation focuses on the improvement of very high temperature thermometry (1100 deg. C to 2480 deg. C), with special emphasis on the application to the field of nuclear reactor safety and severe accident research. Two main projects were undertaken to achieve this objective: - The development, testing and transposition of high-temperature fixed point (HTFP) metal-carbon eutectic cells, from metrology laboratory precision (±0.001 deg. C) to applied research with a reasonable degradation of uncertainties (±3-5 deg. C). - The corrosion study and metallurgical characterization of Type-C thermocouple (service temp. 2300 deg. C) prospective sheath material was undertaken to extend the survivability of TCs used for molten metallic/oxide corium thermometry (below 2000 deg. C)

  20. Comparison of three small-break loss-of-coolant accident tests with different break locations using the system-integrated modular advanced reactor-integral test loop facility to estimate the safety of the smart design

    Directory of Open Access Journals (Sweden)

    Hwang Bae

    2017-08-01

    Full Text Available Three small-break loss-of-coolant accident (SBLOCA tests with safety injection pumps were carried out using the integral-effect test loop for SMART (System-integrated Modular Advanced ReacTor, i.e., the SMART-ITL facility. The types of break are a safety injection system line break, shutdown cooling system line break, and pressurizer safety valve line break. The thermal–hydraulic phenomena show a traditional behavior to decrease the temperature and pressure whereas the local phenomena are slightly different during the early stage of the transient after a break simulation. A safety injection using a high-pressure pump effectively cools down and recovers the inventory of a reactor coolant system. The global trends show reproducible results for an SBLOCA scenario with three different break locations. It was confirmed that the safety injection system is robustly safe enough to protect from a core uncovery.

  1. Perceived organizational support for safety and employee safety voice: the mediating role of coworker support for safety.

    Science.gov (United States)

    Tucker, Sean; Chmiel, Nik; Turner, Nick; Hershcovis, M Sandy; Stride, Chris B

    2008-10-01

    In the present study, we modeled 2 sources of safety support (perceived organizational support for safety and perceived coworker support for safety) as predictors of employee safety voice, that is, speaking out in an attempt to change unsafe working conditions. Drawing on social exchange and social impact theories, we hypothesized and tested a mediated model predicting employee safety voice using a cross-sectional survey of urban bus drivers (n = 213) in the United Kingdom. Hierarchical regression analysis showed that perceived coworker support for safety fully mediated the relationship between perceived organizational support for safety and employee safety voice. This study adds to the employee voice literature by evaluating the important role that coworkers can play in encouraging others to speak out about safety issues. Implications for research and practice related to change-oriented safety communication are discussed.

  2. Radiation safety aspects during nondestructive testing of reactor shielding components by gamma radiometry

    International Nuclear Information System (INIS)

    Viswanathan, S.; Jose, M.T.; Venkatraman, B.

    2016-01-01

    In nuclear facilities, effective shielding of radioactive components and structures are essential to ensure radiation protection to operating personnel. The shield structures are made of lead, steel and concrete with varying thickness of up to 1200 mm. It needs to be verified for shielding integrity, presence of voids, blowholes and defects to avoid exposure to workers and to public at large. Radiometry using gamma source serves as excellent tool for non-destructive examination of such structures and components. Gamma sources of high activity up to 50 Curies (gamma camera type) depending on the thickness of component have to be used. During the testing exposure to the operating personnel needs to be minimized, this requires certain safety procedures to be followed. This paper focuses the methodology to be adapted by means of selection of source, effective training of personnel, compliance with safety requirements and maintenance of source devices

  3. Modelling of particular phenomena observed in PANDA with Gothic

    International Nuclear Information System (INIS)

    Bandurski, Th.; Putz, F.; Andreani, M.; Analytis, M.

    2000-01-01

    PANDA is a large scale facility for investigating the long-term decay heat removal from the containment of a next generation 'passive' Advanced Light Water Reactor (ALWR). The first test series was aimed at the investigation of the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric (GE) Simplified Boiling Water Reactor (SBWR). Recently, the facility is used in the framework of two European projects for investigating the performance of four passive cooling systems, i.e. the Building Condenser (BC) designed by Siemens for the SWR-1000 long-term containment cooling, the Passive Containment Cooling System for the European Simplified Boiling Water Reactor (ESBWR), the Containment Plate Condenser (CPC) and the Isolation Condenser (IC) for cooling of a BWR core. The PANDA tests have the dual objectives of improving confidence in the performance of the passive heat removal mechanisms underlying the design of the tested safety systems and extending the data base available for containment analysis code qualification. Among others, the containment analysis code Gothic was chosen for the analysis of particular phenomena observed during the PANDA tests. Ibis paper presents selected safety relevant phenomena observed in the PANDA tests and identified for the analyses and possible approaches for their modeling with Gothic. (author)

  4. Periodic safety review of the HTR-10 safety analysis

    International Nuclear Information System (INIS)

    Chen Fubing; Zheng Yanhua; Shi Lei; Li Fu

    2015-01-01

    Designed by the Institute of Nuclear and New Energy Technology (INET) of Tsinghua University, the 10 MW High Temperature Gas-cooled Reactor-Test Module (HTR-10) is the first modular High Temperature Gas-cooled Reactor (HTGR) in China. According to the nuclear safety regulations of China, the periodic safety review (PSR) of the HTR-10 was initiated by INET after approved by the National Nuclear Safety Administration (NNSA) of China. Safety analysis of the HTR-10 is one of the key safety factors of the PSR. In this paper, the main contents in the review of safety analysis are summarized; meanwhile, the internal evaluation on the review results is presented by INET. (authors)

  5. Structural observation of long-span suspension bridges for safety assessment: implementation of an optical displacement measurement system

    International Nuclear Information System (INIS)

    Martins, L Lages; Ribeiro, A Silva; Rebordão, J M

    2015-01-01

    This paper addresses the implementation of an optical displacement measurement system in the observation scenario of a long-span suspension bridge and its contribution for structural safety assessment. The metrological background required for quality assurance of the measurements is described, namely, the system's intrinsic parameterization and integration in the SI dimensional traceability chain by calibration, including its measurement uncertainty assessment

  6. Safety test of a supplement, 5-aminolevulinic acid phosphate with sodium ferrous citrate, in diabetic patients treated with oral hypoglycemic agents

    Directory of Open Access Journals (Sweden)

    Naohide Yamashita

    2014-09-01

    Full Text Available Objective: This study aimed to examine the safety of 5-aminolevulinic acid phosphate (5-ALA with sodium ferrous citrate (SFC in diabetic patients treated with one or more oral hypoglycemic agents (OHAs. Background: Recent intervention studies performed in the USA and Japan have shown that a nutritional supplement of 5-ALA with SFC efficiently reduced blood glucose levels in pre-diabetic population without any adverse events. Thus, it was anticipated that 5-ALA with SFC may potentially be taken as a beneficial supplement by diabetic patients who were being treated with OHA therapy. Nevertheless, it is important to examine its safety and efficacy in diabetic population. Methods: This study was a prospective single-blinded, randomized, placebo-controlled and parallel-group comparison study. Medically treated diabetic patients between the ages of 30 and 75 were recruited from the Tokyo metropolitan area of Japan and 45 subjects were selected after screening. These subjects were randomly assigned to three groups: daily intake of 15mg 5-ALA, 50mg 5-ALA, and a placebo (n=15, respectively. The supplement or placebo was administered for 12 weeks followed by a four week washout period. The primary endpoint was safety and occurrence of hypoglycemic attack, while the secondary endpoint was changes of fasting blood glucose (FBG and hemoglobin A1c (HbA1c. Results: Adverse events related to 5-ALA with SFC were not observed in all the groups. Abnormalities in blood and urine tests were not observed either. Significant decrease in FBG was not detected in all the groups. However, there was a small but significant decrease in HbA1c at 4 and 8 week in the 15 mg 5-ALA group. Significant decrease in HbA1c was not observed in the 50 mg 5-ALA group, although a tendency to decrease after 4 weeks was apparent. Conclusion: 5-ALA with SFC is a safe and potentially beneficial supplement if taken by diabetic patients treated with OHAs.

  7. Safety assessment methodologies for near surface disposal facilities. Results of a co-ordinated research project (ISAM). Volume 1: Review and enhancement of safety assessment approaches and tools. Volume 2: Test cases

    International Nuclear Information System (INIS)

    2004-07-01

    For several decades, countries have made use of near surface facilities for the disposal of low and intermediate level radioactive waste. In line with the internationally agreed principles of radioactive waste management, the safety of these facilities needs to be ensured during all stages of their lifetimes, including the post-closure period. By the mid 1990s, formal methodologies for evaluating the long term safety of such facilities had been developed, but intercomparison of these methodologies had revealed a number of discrepancies between them. Consequently, in 1997, the International Atomic Energy Agency launched a Co-ordinated Research Project (CRP) on Improvement of Safety Assessment Methodologies for Near Surface Disposal Facilities (ISAM). The particular objectives of the CRP were to provide a critical evaluation of the approaches and tools used in post-closure safety assessment for proposed and existing near-surface radioactive waste disposal facilities, enhance the approaches and tools used and build confidence in the approaches and tools used. The CRP ran until 2000 and resulted in the development of a harmonized assessment methodology (the ISAM project methodology), which was applied to a number of test cases. Over seventy participants from twenty-two Member States played an active role in the project and it attracted interest from around seven hundred persons involved with safety assessment in seventy-two Member States. The results of the CRP have contributed to the Action Plan on the Safety of Radioactive Waste Management which was approved by the Board of Governors and endorsed by the General Conference in September 2001. Specifically, they contribute to Action 5, which requests the IAEA Secretariat to 'develop a structured and systematic programme to ensure adequate application of the Agency's waste safety standards', by elaborating on the Safety Requirements on 'Near Surface Disposal of Radioactive Waste' (Safety Standards Series No. WS-R-1) and

  8. Safety demonstration tests of air-ventilation system for the postulated explosive burning in a cell of fuel-reprocessing plant

    International Nuclear Information System (INIS)

    Takada, Junichi; Suzuki, Motoe; Tukamoto, Michio; Koike, Tadao; Nishio, Gunji

    1995-03-01

    Safety demonstration tests of an explosive burning in a cell in the reprocessing plant has been carried out in JAERI under the auspices of the Science and Technology Agency, to evaluate the safety of an air-ventilation system during the hypothetical explosion. The postulated explosive burning of organic solvent mixed with nitric acid was simulated by solid explosives. The demonstration test was performed using an industrial scale experimental facility simulating to the ventilation system of the large scale reprocessing plant in JAPAN. Propagations of pressure, temperature, and gas velocity through cells and ducts in the ventilation system were measured during the explosive burning under deflagration. Experimental data in this report can be used to evaluate the transport phenomena of radioactive materials in the ventilation system during the explosion, and also to verify computer code CELVA for the safety analysis of ventilation system in the event of explosion accidents. (author)

  9. Safety Evaluation of Radioactive Material Transport Package under Stacking Test Condition

    International Nuclear Information System (INIS)

    Lee, Ju Chan; Seo, Ki Seog; Yoo, Seong Yeon

    2012-01-01

    Radioactive waste transport package was developed to transport eight drums of low and intermediate level waste(LILW) in accordance with the IAEA and domestic related regulations. The package is classified with industrial package IP-2. IP-2 package is required to undergo a free drop test and a stacking test. After free drop and stacking tests, it should prevent the loss or dispersal of radioactive contents, and loss of shielding integrity which would result in more than 20 % increase in the radiation level at any external surface of the package. The objective of this study is to establish the safety test method and procedure for stacking test and to prove the structural integrities of the IP-2 package. Stacking test and analysis were performed with a compressive load equal to five times the weight of the package for a period of 24 hours using a full scale model. Strains and displacements were measured at the corner fitting of the package during the stacking test. The measured strains and displacements were compared with the analysis results, and there were good agreements. It is very difficult to measure the deflection at the container base, so the maximum deflection of the container base was calculated by the analysis method. The maximum displacement at the corner fitting and deflection at the container base were less than their allowable values. Dimensions of the test model, thickness of shielding material and bolt torque were measured before and after the stacking test. Throughout the stacking test, it was found that there were no loss or dispersal of radioactive contents and no loss of shielding integrity. Thus, the package was shown to comply with the requirements to maintain structural integrity under the stacking condition.

  10. Efficacy and safety testing of mycotoxin-detoxifying agents in broilers following the European Food Safety Authority guidelines.

    Science.gov (United States)

    Osselaere, A; Devreese, M; Watteyn, A; Vandenbroucke, V; Goossens, J; Hautekiet, V; Eeckhout, M; De Saeger, S; De Baere, S; De Backer, P; Croubels, S

    2012-08-01

    Contamination of feeds with mycotoxins is a worldwide problem and mycotoxin-detoxifying agents are used to decrease their negative effect. The European Food Safety Authority recently stated guidelines and end-points for the efficacy testing of detoxifiers. Our study revealed that plasma concentrations of deoxynivalenol and deepoxy-deoxynivalenol were too low to assess efficacy of 2 commercially available mycotoxin-detoxifying agents against deoxynivalenol after 3 wk of continuous feeding of this mycotoxin at concentrations of 2.44±0.70 mg/kg of feed and 7.54±2.20 mg/kg of feed in broilers. This correlates with the poor absorption of deoxynivalenol in poultry. A safety study with 2 commercially available detoxifying agents and veterinary drugs showed innovative results with regard to the pharmacokinetics of 2 antibiotics after oral dosing in the drinking water. The plasma and kidney tissue concentrations of oxytetracycline were significantly higher in broilers receiving a biotransforming agent in the feed compared with control birds. For amoxicillin, the plasma concentrations were significantly higher for broilers receiving an adsorbing agent in comparison to birds receiving the biotransforming agent, but not to the control group. Mycotoxin-detoxifying agents can thus interact with the oral bioavailability of antibiotics depending on the antibiotic and detoxifying agent, with possible adverse effects on the health of animals and humans.

  11. Safety test of an improved multihundred watt FSA: launch abort, solid propellant fire

    International Nuclear Information System (INIS)

    Seabourn, C.M.

    1978-07-01

    This safety test consisted of exposing a simulant-fueled Improved Multihundred Watt Fuel Sphere Assembly, containing a Pt-3008 sphere holding the fuel simulant, to a single proximity fire of UTP-3001 solid rocket propellant for 10.5 min. The graphite outside shell sustained only minor abrasion damage. It was covered on one side with a heavy deposit of alumina from the fire mixed with silica from the test bed. The Pt-3008 shell had small amounts of carbon, alumina, and silica deposited on its surface but sustained no other damage. The PT-3008 sphere was not breached, and therefore the fuel sphere assembly would not release fuel in a solid-propellant fire of a launch abort. 12 figures

  12. Minimum detection efficiencies for a loophole-free observable-asymmetric Bell-type test

    International Nuclear Information System (INIS)

    Garbarino, G.

    2010-01-01

    We discuss the problem of finding the most favorable conditions for closing the detection loophole in a test of local realism with a Bell inequality. For a generic nonmaximally entangled two-qubit state and two incompatible bases to be adopted for alternative measurements of two observables a and b on each party, we apply Hardy's proof of nonlocality without inequality and derive an Eberhard-like inequality. For an infinity of nonmaximally entangled states we find that it is possible to refute local realism by requiring perfect detection efficiency for only one of the two observables, say b, to be measured on each party: The test is free from the detection loophole for any value of the detection efficiency corresponding to the other observable a. The maximum tolerable noise in such a loophole-free observable-asymmetric test is also evaluated.

  13. Computer-simulated safety test of a fink-type roof truss

    International Nuclear Information System (INIS)

    Afolaxan, J.O.

    2003-01-01

    The safety of a Fink-type truss system following the BS5950/sup 1/ design requirements is examined. The design point approach of reliability analysis is developed to determine the safety indices for the individual members and the joints which are assumed filet-welded. Consequently, for assumed loading options, the entire system safety indices are reported indicating a need for the re-appraisal of the adopted criteria. (author)

  14. SFR Safety Considerations

    International Nuclear Information System (INIS)

    Glatz, Jean-Paul

    2012-01-01

    Objectives of the Safety and Operation Project: • analysis and experiments that support approaches and assess performance of specific safety features, • development and verification of computational tools and validation of models employed in safety assessment and facility licensing, and • valorisation of reactor operation, from experience and testing in operating SFR plants

  15. Observational tests of FRW world models

    International Nuclear Information System (INIS)

    Lahav, Ofer

    2002-01-01

    Observational tests for the cosmological principle are reviewed. Assuming the FRW metric we then summarize estimates of cosmological parameters from various datasets, in particular the cosmic microwave background and the 2dF galaxy redshift survey. These and other analyses suggest a best-fit Λ-cold dark matter model with Ω m = 1 - Ω l ∼ 0.3 and H 0 ∼ 70 km s -1 Mpc -1 . It is remarkable that different measurements converge to this 'concordance model', although it remains to be seen if the two main components of this model, the dark matter and the dark energy, are real entities or just 'epicycles'. We point out some open questions related to this fashionable model

  16. Safety and effectiveness of eribulin in Japanese patients with locally advanced or metastatic breast cancer: a post-marketing observational study.

    Science.gov (United States)

    Watanabe, Junichiro; Ito, Yoshinori; Ohsumi, Shozo; Mizutani, Mitsuhiro; Tashiro, Hideya; Sakurai, Kenichi; Takahashi, Masato; Saito, Tsuyoshi; Tsurutani, Junji; Mukai, Hirofumi; Yoshinami, Tetsuhiro; Takao, Shintaro; Yamamoto, Yasuhisa; Matsuoka, Toshiyuki; Iwase, Hirotaka; Iwata, Hiroji; Nakamura, Seigo; Saeki, Toshiaki

    2017-12-01

    Background This large-scale study was conducted to evaluate the safety and effectiveness of eribulin for the treatment of inoperable or recurrent breast cancer in real-world settings in Japan. Methods Between July and December 2011, eligible patients with inoperable or recurrent breast cancer receiving eribulin for the first time were centrally registered and observed for 1 year. Eribulin was administered intravenously (1.4 mg/m 2 ) on days 1 and 8 of every 3-week cycle. The primary endpoint was the frequency and intensity of adverse drug reactions (ADRs). Secondary endpoints included overall response rate (ORR) and time to treatment failure (TTF). Results Of 968 patients registered at 325 institutions, 951 and 671 were included in the safety and effectiveness analyses, respectively. In the safety population, ADRs were observed in 841 patients (88.4%). The most common (≥15% incidence) were neutropenia (66.6%), leukopenia (62.4%), lymphopenia (18.4%), and peripheral neuropathy (16.8%). The most common grade ≥ 3 ADRs (>5% incidence) were neutropenia (59.8%), leukopenia (50.5%), lymphopenia (16.1%), and febrile neutropenia (7.7%). In the effectiveness population, ORR was 16.5% (95% confidence interval: 13.7, 19.4). The median TTF was 127 days (95% confidence interval: 120, 134). Conclusions The safety and effectiveness profile of eribulin was consistent with prior studies. Eribulin had a favorable risk-benefit balance when used in real-world clinical settings.

  17. Validity of instruments to assess students' travel and pedestrian safety

    Directory of Open Access Journals (Sweden)

    Baranowski Tom

    2010-05-01

    Full Text Available Abstract Background Safe Routes to School (SRTS programs are designed to make walking and bicycling to school safe and accessible for children. Despite their growing popularity, few validated measures exist for assessing important outcomes such as type of student transport or pedestrian safety behaviors. This research validated the SRTS school travel survey and a pedestrian safety behavior checklist. Methods Fourth grade students completed a brief written survey on how they got to school that day with set responses. Test-retest reliability was obtained 3-4 hours apart. Convergent validity of the SRTS travel survey was assessed by comparison to parents' report. For the measure of pedestrian safety behavior, 10 research assistants observed 29 students at a school intersection for completion of 8 selected pedestrian safety behaviors. Reliability was determined in two ways: correlations between the research assistants' ratings to that of the Principal Investigator (PI and intraclass correlations (ICC across research assistant ratings. Results The SRTS travel survey had high test-retest reliability (κ = 0.97, n = 96, p Conclusions These validated instruments can be used to assess SRTS programs. The pedestrian safety behavior checklist may benefit from further formative work.

  18. Using field feedback to estimate failure rates of safety-related systems

    International Nuclear Information System (INIS)

    Brissaud, Florent

    2017-01-01

    The IEC 61508 and IEC 61511 functional safety standards encourage the use of field feedback to estimate the failure rates of safety-related systems, which is preferred than generic data. In some cases (if “Route 2_H” is adopted for the 'hardware safety integrity constraints”), this is even a requirement. This paper presents how to estimate the failure rates from field feedback with confidence intervals, depending if the failures are detected on-line (called 'detected failures', e.g. by automatic diagnostic tests) or only revealed by proof tests (called 'undetected failures'). Examples show that for the same duration and number of failures observed, the estimated failure rates are basically higher for “undetected failures” because, in this case, the duration observed includes intervals of time where it is unknown that the elements have failed. This points out the need of using a proper approach for failure rates estimation, especially for failures that are not detected on-line. Then, this paper proposes an approach to use the estimated failure rates, with their uncertainties, for PFDavg and PFH assessment with upper confidence bounds, in accordance with IEC 61508 and IEC 61511 requirements. Examples finally show that the highest SIL that can be claimed for a safety function can be limited by the 90% upper confidence bound of PFDavg or PFH. The requirements of the IEC 61508 and IEC 61511 relating to the data collection and analysis should therefore be properly considered for the study of all safety-related systems. - Highlights: • This paper deals with requirements of the IEC 61508 and IEC 61511 for using field feedback to estimate failure rates of safety-related systems. • This paper presents how to estimate the failure rates from field feedback with confidence intervals for failures that are detected on-line. • This paper presents how to estimate the failure rates from field feedback with confidence intervals for failures that are only revealed by

  19. Local tests of gravitation with Gaia observations of Solar System Objects

    Science.gov (United States)

    Hees, Aurélien; Le Poncin-Lafitte, Christophe; Hestroffer, Daniel; David, Pedro

    2018-04-01

    In this proceeding, we show how observations of Solar System Objects with Gaia can be used to test General Relativity and to constrain modified gravitational theories. The high number of Solar System objects observed and the variety of their orbital parameters associated with the impressive astrometric accuracy will allow us to perform local tests of General Relativity. In this communication, we present a preliminary sensitivity study of the Gaia observations on dynamical parameters such as the Sun quadrupolar moment and on various extensions to general relativity such as the parametrized post-Newtonian parameters, the fifth force formalism and a violation of Lorentz symmetry parametrized by the Standard-Model extension framework. We take into account the time sequences and the geometry of the observations that are particular to Gaia for its nominal mission (5 years) and for an extended mission (10 years).

  20. Test-based approach to cable tray support system analysis and design: Behavior and test methods

    Energy Technology Data Exchange (ETDEWEB)

    Reigles, Damon G., E-mail: dreigles@engnovex.com [engNoveX, Inc., 19C Trolley Square, Wilmington, DE 19806 (United States); Brachmann, Ingo; Johnson, William H. [Bechtel Nuclear, Security & Environmental, 12011 Sunset Hills Rd, Suite 110, Reston, VA 20190 (United States); Gürbüz, Orhan [Tobolski Watkins Engineering, Inc., 4125 Sorrento Valley Blvd, Suite B, San Diego, CA 92121 (United States)

    2016-06-15

    Highlights: • Describes dynamic response behavior of unistrut type cable tray supports. • Summarizes observations from past full-scale shake table test programs. • Outlines testing methodologies necessary to identify key system parameters. - Abstract: Nuclear power plant safety-related cable tray support systems subjected to seismic loadings were originally understood and designed to behave as linear elastic systems. This behavioral paradigm persisted until the early 1980s when, due to evolution of regulatory criteria, some as-installed systems needed to be qualified to higher seismic motions than originally designed for. This requirement prompted a more in-depth consideration of the true seismic response behavior of support systems. Several utilities initiated extensive test programs, which demonstrated that trapeze strut-type cable tray support systems exhibited inelastic and nonlinear response behaviors with plastic hinging at the connections together with high damping due to bouncing of cables in the trays. These observations were used to demonstrate and justify the seismic adequacy of the aforementioned as-installed systems. However, no formalized design methodology or criteria were ever established to facilitate use of these test data for future evaluations. This paper assimilates and reviews the various test data and conclusions for the purpose of developing a design methodology for the seismic qualification of safety-related cable tray support systems.

  1. Predicting fatigue and psychophysiological test performance from speech for safety critical environments

    Directory of Open Access Journals (Sweden)

    Khan Richard Baykaner

    2015-08-01

    Full Text Available Automatic systems for estimating operator fatigue have application in safety-critical environments. A system which could estimate level of fatigue from speech would have application in domains where operators engage in regular verbal communication as part of their duties. Previous studies on the prediction of fatigue from speech have been limited because of their reliance on subjective ratings and because they lack comparison to other methods for assessing fatigue. In this paper we present an analysis of voice recordings and psychophysiological test scores collected from seven aerospace personnel during a training task in which they remained awake for 60 hours. We show that voice features and test scores are affected by both the total time spent awake and the time position within each subject’s circadian cycle. However, we show that time spent awake and time of day information are poor predictors of the test results; while voice features can give good predictions of the psychophysiological test scores and sleep latency. Mean absolute errors of prediction are possible within about 17.5% for sleep latency and 5-12% for test scores. We discuss the implications for the use of voice as a means to monitor the effects of fatigue on cognitive performance in practical applications.

  2. Technical evaluation of the noise and isolation testing of the safety features actuation system at the Davis Besse Nuclear Power Station, Unit 1

    International Nuclear Information System (INIS)

    Selan, J.C.

    1981-07-01

    This report documents the technical evaluation of the noise and isolation testing of the safety features actuation system at the Davis Besse Nuclear Power Station, Unit 1. The tests were to verify that faults on the non-Class 1E circuits would not propagate to the Class 1E circuits and degrade them below acceptable levels. The tests conducted demonstrated that the safety features actuation system did not degrade below acceptable levels nor was the system's ability to perform its protective functions affected

  3. PANDA: a Large Scale Multi-Purpose Test Facility for LWR Safety Research

    Energy Technology Data Exchange (ETDEWEB)

    Dreier, Joerg; Paladino, Domenico; Huggenberger, Max; Andreani, Michele [Laboratory for Thermal-Hydraulics, Nuclear Energy and Safety Research Department, Paul Scherrer Institut (PSI), CH-5232 Villigen PSI (Switzerland); Yadigaroglu, George [ETH Zuerich, Technoparkstrasse 1, Einstein 22- CH-8005 Zuerich (Switzerland)

    2008-07-01

    PANDA is a large-scale multi-purpose thermal-hydraulics test facility, built and operated by PSI. Due to its modular structure, PANDA provides flexibility for a variety of applications, ranging from integral containment system investigations, primary system tests, component experiments to large-scale separate-effects tests. For many applications, the experimental results are directly used for example for concept demonstrations or for the characterisation of phenomena or components, but all the experimental data generated in the various test campaigns is unique and was or/and will still be widely used for the validation and improvement of a variety of computer codes, including codes with 3D capabilities, for reactor safety analysis. The paper provides an overview of the already completed and on-going research programs performed in the PANDA facility in the different area of applications, including the main results and conclusions of the investigations. In particular the advanced passive containment cooling system concept investigations of the SBWR, ESBWR as well as of the SWR1000 in relation to various aspects are presented and the main findings are summarised. Finally the goals, planned investigations and expected results of the on-going OECD project SETH-2 are presented. (authors)

  4. PANDA: a Large Scale Multi-Purpose Test Facility for LWR Safety Research

    International Nuclear Information System (INIS)

    Dreier, Joerg; Paladino, Domenico; Huggenberger, Max; Andreani, Michele; Yadigaroglu, George

    2008-01-01

    PANDA is a large-scale multi-purpose thermal-hydraulics test facility, built and operated by PSI. Due to its modular structure, PANDA provides flexibility for a variety of applications, ranging from integral containment system investigations, primary system tests, component experiments to large-scale separate-effects tests. For many applications, the experimental results are directly used for example for concept demonstrations or for the characterisation of phenomena or components, but all the experimental data generated in the various test campaigns is unique and was or/and will still be widely used for the validation and improvement of a variety of computer codes, including codes with 3D capabilities, for reactor safety analysis. The paper provides an overview of the already completed and on-going research programs performed in the PANDA facility in the different area of applications, including the main results and conclusions of the investigations. In particular the advanced passive containment cooling system concept investigations of the SBWR, ESBWR as well as of the SWR1000 in relation to various aspects are presented and the main findings are summarised. Finally the goals, planned investigations and expected results of the on-going OECD project SETH-2 are presented. (authors)

  5. Drug safety data mining with a tree-based scan statistic.

    Science.gov (United States)

    Kulldorff, Martin; Dashevsky, Inna; Avery, Taliser R; Chan, Arnold K; Davis, Robert L; Graham, David; Platt, Richard; Andrade, Susan E; Boudreau, Denise; Gunter, Margaret J; Herrinton, Lisa J; Pawloski, Pamala A; Raebel, Marsha A; Roblin, Douglas; Brown, Jeffrey S

    2013-05-01

    In post-marketing drug safety surveillance, data mining can potentially detect rare but serious adverse events. Assessing an entire collection of drug-event pairs is traditionally performed on a predefined level of granularity. It is unknown a priori whether a drug causes a very specific or a set of related adverse events, such as mitral valve disorders, all valve disorders, or different types of heart disease. This methodological paper evaluates the tree-based scan statistic data mining method to enhance drug safety surveillance. We use a three-million-member electronic health records database from the HMO Research Network. Using the tree-based scan statistic, we assess the safety of selected antifungal and diabetes drugs, simultaneously evaluating overlapping diagnosis groups at different granularity levels, adjusting for multiple testing. Expected and observed adverse event counts were adjusted for age, sex, and health plan, producing a log likelihood ratio test statistic. Out of 732 evaluated disease groupings, 24 were statistically significant, divided among 10 non-overlapping disease categories. Five of the 10 signals are known adverse effects, four are likely due to confounding by indication, while one may warrant further investigation. The tree-based scan statistic can be successfully applied as a data mining tool in drug safety surveillance using observational data. The total number of statistical signals was modest and does not imply a causal relationship. Rather, data mining results should be used to generate candidate drug-event pairs for rigorous epidemiological studies to evaluate the individual and comparative safety profiles of drugs. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Demonstration test on the safety of a cell ventilation system during a hypothetical explosive burning in a fuel reprocessing plant

    International Nuclear Information System (INIS)

    Suzuki, Motoe; Nishio, Gunji; Takada, Junichi; Tsukamoto, Michio; Koike, Tadao

    1993-01-01

    To demonstrate the safety of an air ventilation system of cells in a fuel reprocessing plant under a postulated explosive burning caused by solvent fire or by thermal decomposition of nitrated solvent, four types of demonstration tests have been conducted using a large-scale facility simulating a cell ventilation system of an actual reprocessing plant, thus revealing effective mitigation by cell and duct structures on the pressure and temperature pulses generated by explosive burning. In boilover burning tests, solvent fire in a model cell was observed with various sizes of burning surface area as a main parameter, and analysis was performed on the factors dominating the magnitude of boilover burning, revealing that the magnitude strongly depends on accumulated amounts and their ratio of oxygen and solvent vapor present in the cell. In deflagration tests, solid rocket fuel was burned in the cell to simulate the explosive source. The generated pressure and temperature pulses were effectively declined by the cell and duct structures and the integrity of the ventilation system was kept. In blower tests, a centrifugal turbo blower was imposed by a lump of air with a larger flow rate than the rated one by about six times to observe the transient response of the blower fan and motor. It was found that integrity of the blower was kept. In pressure transient tests, compressed air was blown into the cell to induce a mild transient state of fluid dynamics inside the facility, and a variety of data were successfully obtained to be used for the verification and improvement of a computer code. In all the tests, transient overloading of gas caused no damage on HEPA filters, and overloading on the blower motor was avoided either by the slipping of transmission belt or by the acceleration of blower fan rotation during peak flow. (author)

  7. Qualification of safety-critical software for digital reactor safety system in nuclear power plants

    International Nuclear Information System (INIS)

    Kwon, Kee-Choon; Park, Gee-Yong; Kim, Jang-Yeol; Lee, Jang-Soo

    2013-01-01

    This paper describes the software qualification activities for the safety-critical software of the digital reactor safety system in nuclear power plants. The main activities of the software qualification processes are the preparation of software planning documentations, verification and validation (V and V) of the software requirements specifications (SRS), software design specifications (SDS) and codes, and the testing of the integrated software and integrated system. Moreover, the software safety analysis and software configuration management are involved in the software qualification processes. The V and V procedure for SRS and SDS contains a technical evaluation, licensing suitability evaluation, inspection and traceability analysis, formal verification, software safety analysis, and an evaluation of the software configuration management. The V and V processes for the code are a traceability analysis, source code inspection, test case and test procedure generation. Testing is the major V and V activity of the software integration and system integration phases. The software safety analysis employs a hazard operability method and software fault tree analysis. The software configuration management in each software life cycle is performed by the use of a nuclear software configuration management tool. Through these activities, we can achieve the functionality, performance, reliability, and safety that are the major V and V objectives of the safety-critical software in nuclear power plants. (author)

  8. Tiered guidance for risk-informed environmental health and safety testing of nanotechnologies

    International Nuclear Information System (INIS)

    Collier, Zachary A.; Kennedy, Alan J.; Poda, Aimee R.; Cuddy, Michael F.; Moser, Robert D.; MacCuspie, Robert I.; Harmon, Ashley; Plourde, Kenton; Haines, Christopher D.; Steevens, Jeffery A.

    2015-01-01

    Provided the rapid emergence of novel technologies containing engineered nanomaterials, there is a need to better understand the potential environmental, health, and safety effects of nanotechnologies before wide-scale deployment. However, the unique properties of nanomaterials and uncertainty regarding applicable test methods have led to a lack of consensus regarding the collection and evaluation of data related to hazard and exposure potentials. Often, overly conservative approaches to characterization and data collection result in prolonged, unfocused, or irrelevant testing, which increases costs and delays deployment. In this paper, we provide a novel testing guidance framework for determining whether a nanotechnology has the potential to release material with nano-specific parameters that pose a risk to humans or the environment. The framework considers methods to categorize nanotechnologies by their structure and within their relevant-use scenarios to inform testing in a time- and resource-limited reality. Based on the precedent of dredged sediment testing, a five-tiered approach is proposed in which opportunities are presented to conclude testing once sufficient risk-related information has been collected, or that the technology in question does not require nano-specific scrutiny. A series of screening stages are suggested, covering relevant aspects including size, surface area, distribution, unique behaviors, and release potential. The tiered, adaptive guidance approach allows users to concentrate on collecting the most relevant data, thus accelerating technology deployment while minimizing risk

  9. A study of software safety analysis system for safety-critical software

    International Nuclear Information System (INIS)

    Chang, H. S.; Shin, H. K.; Chang, Y. W.; Jung, J. C.; Kim, J. H.; Han, H. H.; Son, H. S.

    2004-01-01

    The core factors and requirements for the safety-critical software traced and the methodology adopted in each stage of software life cycle are presented. In concept phase, Failure Modes and Effects Analysis (FMEA) for the system has been performed. The feasibility evaluation of selected safety parameter was performed and Preliminary Hazards Analysis list was prepared using HAZOP(Hazard and Operability) technique. And the check list for management control has been produced via walk-through technique. Based on the evaluation of the check list, activities to be performed in requirement phase have been determined. In the design phase, hazard analysis has been performed to check the safety capability of the system with regard to safety software algorithm using Fault Tree Analysis (FTA). In the test phase, the test items based on FMEA have been checked for fitness guided by an accident scenario. The pressurizer low pressure trip algorithm has been selected to apply FTA method to software safety analysis as a sample. By applying CASE tool, the requirements traceability of safety critical system has been enhanced during all of software life cycle phases

  10. Experimental observations of boric acid precipitation scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Vaghetto, R., E-mail: r.vaghetto@tamu.edu; Childs, M., E-mail: masonchilds@tamu.edu; Jones, P., E-mail: pgjones87@tamu.edu; Lee, S., E-mail: sayalee@tamu.edu; Kee, E., E-mail: erniekee@gmail.com; Hassan, Y.A., E-mail: y-hassan@tamu.edu

    2017-02-15

    During a Loss of Coolant Accident (LOCA) in Light Water Reactors (LWR), borated water is injected into the core through the safety injection system. The continuous vaporization of the water from the core may increase the concentration of boric acid in the core that, under certain conditions may reach the solubility limit and precipitate. This includes scenarios where the liquid water supply to the core is affected by possible blockages due to debris accumulation. Questions have been raised on the effects of the precipitate in the core on the flow behavior, including the possibility of additional blockages produced by precipitate accumulation. A simple experimental facility was constructed to perform experimental observations of the behavior of borated water under the combined effects of the boiling and the boric acid precipitation (BAP). The facility consists of a transparent polycarbonate vertical pipe where forty-five heated rods have been installed to supply the power to the water to reach the saturation temperature, and maintain a desired boil-off rate. The layout and geometry of the experimental apparatus were conceived to emulate a simplified core of a Pressurized Water Reactor (PWR). Experimental observations have been conducted under two different conditions. Preliminary tests were conducted to observe the behavior of the water and the boric acid precipitate during a boil-off scenario without borated water addition (decreasing water level). During the main test runs, borated water was constantly injected from the top of the test section to maintain a constant mixture level in the test section. Both tests assumed no flow from the bottom of the test section which may be the case of PWR LOCA scenarios in presence of debris-generated core blockage. The observations performed with a set of cameras installed around the test section showed interesting effects of the vapor bubbles on the boric acid precipitate migration and accumulation in the test section. The

  11. Supporting documents for LLL area 27 (410 area) safety analysis reports, Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Odell, B. N. [comp.

    1977-02-01

    The following appendices are common to the LLL Safety Analysis Reports Nevada Test Site and are included here as supporting documents to those reports: Environmental Monitoring Report for the Nevada Test Site and Other Test Areas Used for Underground Nuclear Detonations, U. S. Environmental Protection Agency, Las Vegas, Rept. EMSL-LV-539-4 (1976); Selected Census Information Around the Nevada Test Site, U. S. Environmental Protection Agency, Las Vegas, Rept. NERC-LV-539-8 (1973); W. J. Hannon and H. L. McKague, An Examination of the Geology and Seismology Associated with Area 410 at the Nevada Test Site, Lawrence Livermore Laboratory, Livermore, Rept. UCRL-51830 (1975); K. R. Peterson, Diffusion Climatology for Hypothetical Accidents in Area 410 of the Nevada Test Site, Lawrence Livermore Laboratory, Livermore, Rept. UCRL-52074 (1976); J. R. McDonald, J. E. Minor, and K. C. Mehta, Development of a Design Basis Tornado and Structural Design Criteria for the Nevada Test Site, Nevada, Lawrence Livermore Laboratory, Livermore, Rept. UCRL-13668 (1975); A. E. Stevenson, Impact Tests of Wind-Borne Wooden Missiles, Sandia Laboratories, Tonopah, Rept. SAND 76-0407 (1976); and Hydrology of the 410 Area (Area 27) at the Nevada Test Site.

  12. Assessment of Driving Safety in Older Adults with Mild Cognitive Impairment.

    Science.gov (United States)

    Anstey, Kaarin J; Eramudugolla, Ranmalee; Chopra, Sidhant; Price, Jasmine; Wood, Joanne M

    2017-01-01

    With population aging, drivers with mild cognitive impairment (MCI) are increasing; however, there is little evidence available regarding their safety. We aimed to evaluate risk of unsafe on-road driving performance among older adults with MCI. The study was a cross-sectional observational study, set in Canberra, Australia. Participants were non-demented, current drivers (n = 302) aged 65 to 96 years (M = 75.7, SD = 6.18, 40% female) recruited through the community and primary and tertiary care clinics. Measures included a standardized on-road driving test (ORT), a battery of screening measures designed to evaluate older driver safety (UFOV®, DriveSafe, Multi-D), a neurocognitive test battery, and questionnaires on driving history and behavior. Using Winblad criteria, 57 participants were classified as having MCI and 245 as cognitively normal (CN). While the MCI group had a significantly lower overall safety rating on the ORT (5.61 versus 6.05, p = 0.03), there was a wide range of driving safety scores in the CN and MCI groups. The MCI group performed worse than the CN group on the off-road screening tests. The best fitting model of predictors of ORT performance across the combined sample included age, the Multi-D, and DriveSafe, classifying 90.4% of the sample correctly. Adults with MCI exhibit a similar range of driving ability to CN adults, although on average they scored lower on off-road and on-road assessments. Driving specific tests were more strongly associated with safety ratings than traditional neuropsychological tests.

  13. Modeling safety instrumented systems with MooN voting architectures addressing system reconfiguration for testing

    International Nuclear Information System (INIS)

    Torres-Echeverria, A.C.; Martorell, S.; Thompson, H.A.

    2011-01-01

    This paper addresses the modeling of probability of dangerous failure on demand and spurious trip rate of safety instrumented systems that include MooN voting redundancies in their architecture. MooN systems are a special case of k-out-of-n systems. The first part of the article is devoted to the development of a time-dependent probability of dangerous failure on demand model with capability of handling MooN systems. The model is able to model explicitly common cause failure and diagnostic coverage, as well as different test frequencies and strategies. It includes quantification of both detected and undetected failures, and puts emphasis on the quantification of common cause failure to the system probability of dangerous failure on demand as an additional component. In order to be able to accommodate changes in testing strategies, special treatment is devoted to the analysis of system reconfiguration (including common cause failure) during test of one of its components, what is then included in the model. Another model for spurious trip rate is also analyzed and extended under the same methodology in order to empower it with similar capabilities. These two models are powerful enough, but at the same time simple, to be suitable for handling of dependability measures in multi-objective optimization of both system design and test strategies for safety instrumented systems. The level of modeling detail considered permits compliance with the requirements of the standard IEC 61508. The two models are applied to brief case studies to demonstrate their effectiveness. The results obtained demonstrated that the first model is adequate to quantify time-dependent PFD of MooN systems during different system states (i.e. full operation, test and repair) and different MooN configurations, which values are averaged to obtain the PFD avg . Also, it was demonstrated that the second model is adequate to quantify STR including spurious trips induced by internal component failure and

  14. Testing of the multi-application small light water reactor (MASLWR) passive safety systems

    International Nuclear Information System (INIS)

    Reyes, Jose N.; Groome, John; Woods, Brian G.; Young, Eric; Abel, Kent; Yao, You; Yoo, Yeon Jong

    2007-01-01

    Experimental thermal hydraulic research has been conducted at Oregon State University for the purpose of assessing the performance of a new reactor design concept, the multi-application small light water reactor (MASLWR). The MASLWR is a pressurized light water reactor design with a net output of 35 MWe that uses natural circulation in both normal and transient operation. Due to its small size, portability and modularity, the MASLWR design is well suited to help fill the potential need for grid appropriate reactor designs for smaller electricity grids as may be found in developing or remote regions. The purpose of the OSU MASLWR test facility is to assess the operation of the MASLWR under normal full operating pressure and full temperature conditions and to assess the passive safety systems under transient conditions. The data generated by the testing program will be used to assess computer code calculations and to provide a better understanding of the thermal-hydraulic phenomena in the design of the MASLWR NSSS. During this testing program, four tests were conducted at the OSU MASLWR test facility. These tests included one design basis accident and one beyond design basis accident. During the performance of these tests, plant operations to include start up, normal operation and shut down evolutions were demonstrated successfully

  15. US Department of Energy Environment, Safety and Health Progress Assessment of the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    1992-08-01

    This report documents the result of the US Department of Energy (DOE) Environment, Safety, and Health (ES&H) Progress Assessment of the Nevada Test Site (NTS), Nye County, Nevada. The assessment, which was conducted from July 20 through August 4, 1992, included a selective review of the ES&H management systems and progress of the responsible DOE Headquarters Program Offices; the DOE Nevada Field Office (NV); and the site contractors. The ES&H Progress Assessments are part of the Secretary of Energy`s continuing effort to institutionalize line management accountability and the self-assessment process throughout DOE and its contractor organizations. This report presents a summary of issues and progress in the areas of environment, safety and health, and management.

  16. US Department of Energy Environment, Safety and Health Progress Assessment of the Nevada Test Site

    International Nuclear Information System (INIS)

    1992-08-01

    This report documents the result of the US Department of Energy (DOE) Environment, Safety, and Health (ES ampersand H) Progress Assessment of the Nevada Test Site (NTS), Nye County, Nevada. The assessment, which was conducted from July 20 through August 4, 1992, included a selective review of the ES ampersand H management systems and progress of the responsible DOE Headquarters Program Offices; the DOE Nevada Field Office (NV); and the site contractors. The ES ampersand H Progress Assessments are part of the Secretary of Energy's continuing effort to institutionalize line management accountability and the self-assessment process throughout DOE and its contractor organizations. This report presents a summary of issues and progress in the areas of environment, safety and health, and management

  17. Safety quality classification test of the sealed neutron sources used in start-up neutron source rods for Qinshan Nuclear Power Plant

    International Nuclear Information System (INIS)

    Yao Chunbing; Guo Gang; Chao Jinglan; Duan Liming

    1992-01-01

    According to the regulations listed in the GB4075, the safety quality classification tests have been carried out for the neutron sources. The test items include temperature, external pressure, impact, vibration and puncture, Two dummy sealed sources are used for each test item. The testing equipment used have been examined and verified to be qualified by the measuring department which is admitted by the National standard Bureau. The leak rate of each tested sample is measured by UL-100 Helium Leak Detector (its minimum detectable leak rate is 1 x 10 -10 Pa·m 3 ·s -1 ). The samples with leak rate less than 1.33 x 10 -8 Pa·m 3 ·s -1 are considered up to the standard. The test results show the safety quality classification class of the neutron sources have reached the class of GB/E66545 which exceeds the preset class

  18. A summary of the Fire Testing Program at the German HDR Test Facility

    International Nuclear Information System (INIS)

    Nowlen, S.P.

    1995-11-01

    This report provides an overview of the fire safety experiments performed under the sponsorship of the German government in the containment building of the decommissioned pilot nuclear power plant known as HDR. This structure is a highly complex, multi-compartment, multi-level building which has been used as the test bed for a wide range of nuclear power plant operation safety experiments. These experiments have included numerous fire tests. Test fire fuel sources have included gas burners, wood cribs, oil pools, nozzle release oil fires, and cable in cable trays. A wide range of ventilation conditions including full natural ventilation, full forced ventilation, and combined natural and forced ventilation have been evaluated. During most of the tests, the fire products mixed freely with the full containment volume. Macro-scale building circulation patterns which were very sensitive to such factors as ventilation configuration were observed and characterized. Testing also included the evaluation of selective area pressurization schemes as a means of smoke control for emergency access and evacuation stairwells

  19. Hydroxyethyl starch 130/0.42/6:1 for perioperative plasma volume replacement in 1130 children: results of an European prospective multicenter observational postauthorization safety study (PASS)

    NARCIS (Netherlands)

    Sümpelmann, Robert; Kretz, Franz-Josef; Luntzer, Robert; de Leeuw, Thomas G.; Mixa, Vladimir; Gäbler, Ralf; Eich, Christoph; Hollmann, Markus W.; Osthaus, Wilhelm A.

    2012-01-01

    Introduction: Third-generation hydroxyethyl starch (HES) is now approved also for the use in children, but safety studies including large numbers of pediatric patients are still missing. Therefore, we performed an European multicentric prospective observational postauthorization safety study (PASS)

  20. Radiation Safety in Industrial Radiography. Specific Safety Guide

    International Nuclear Information System (INIS)

    2011-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  1. Examining the safety of menstrual cups among rural primary school girls in western Kenya: observational studies nested in a randomised controlled feasibility study.

    Science.gov (United States)

    Juma, Jane; Nyothach, Elizabeth; Laserson, Kayla F; Oduor, Clifford; Arita, Lilian; Ouma, Caroline; Oruko, Kelvin; Omoto, Jackton; Mason, Linda; Alexander, Kelly T; Fields, Barry; Onyango, Clayton; Phillips-Howard, Penelope A

    2017-05-04

    Examine the safety of menstrual cups against sanitary pads and usual practice in Kenyan schoolgirls. Observational studies nested in a cluster randomised controlled feasibility study. 30 primary schools in a health and demographic surveillance system in rural western Kenya. Menstruating primary schoolgirls aged 14-16 years participating in a menstrual feasibility study. Insertable menstrual cup, monthly sanitary pads or 'usual practice' (controls). Staphylococcus aureus vaginal colonization, Escherichia coli growth on sampled used cups, toxic shock syndrome or other adverse health outcomes. Among 604 eligible girls tested, no adverse event or TSS was detected over a median 10.9 months follow-up. S. aureus prevalence was 10.8%, with no significant difference over intervention time or between groups. Of 65  S.aureus positives at first test, 49 girls were retested and 10 (20.4%) remained positive. Of these, two (20%) sample isolates tested positive for toxic shock syndrome toxin-1; both girls were provided pads and were clinically healthy. Seven per cent of cups required replacements for loss, damage, dropping in a latrine or a poor fit. Of 30 used cups processed for E. coli growth, 13 (37.1%, 95% CI 21.1% to 53.1%) had growth. E. coli growth was greatest in newer compared with established users (53%vs22.2%, p=0.12). Among this feasibility sample, no evidence emerged to indicate menstrual cups are hazardous or cause health harms among rural Kenyan schoolgirls, but large-scale trials and post-marketing surveillance should continue to evaluate cup safety. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Review on conformance of JMTR reactor facility to safety design examination guides for water-cooled reactors for test and research

    International Nuclear Information System (INIS)

    Ide, Hiroshi; Naka, Michihiro; Sakuta, Yoshiyuki; Hori, Naohiko; Matsui, Yoshinori; Miyazawa, Masataka

    2009-03-01

    The safety design examination guides for water-cooled reactors for test and research are formulated as fundamental judgements on the basic design validity for licensing from a viewpoint of the safety. Taking the refurbishment opportunity of the JMTR, the conformance of the JMTR reactor facility to current safety design examination guides was reviewed with licensing documents, annexes and related documents. As a result, it was found that licensing documents fully satisfied the requirements of the current guides. Moreover, it was found that the JMTR reactor facility itself also satisfied the guides requirements as well as the safety performance, since the facility with safety function such as structure, systems, devices had been installed based on the licensing documents under the permission by the regulation authority. Important devices for safety have been produced under authorization of regulating authority. Therefore, it was confirmed that the licensing was conformed to guides, and that the JMTR has enough performance. (author)

  3. A Sensitivity Study of Human Errors in Optimizing Surveillance Test Interval (STI) and Allowed Outage Time (AOT) of Standby Safety System

    International Nuclear Information System (INIS)

    Chung, Dae Wook; Shin, Won Ky; You, Young Woo; Yang, Hui Chang

    1998-01-01

    In most cases, the surveillance test intervals (STIs), allowed outage times (AOTS) and testing strategies of safety components in nuclear power plant are prescribed in plant technical specifications. And, in general, it is required that standby safety system shall be redundant (i.e., composed of multiple components) and these components are tested by either staggered test strategy or sequential test strategy. In this study, a linear model is presented to incorporate the effects of human errors associated with test into the evaluation of unavailability. The average unavailabilities of 1/4, 2/4 redundant systems are computed considering human error and testing strategy. The adverse effects of test on system unavailability, such as component wear and test-induced transient have been modelled. The final outcome of this study would be the optimized human error domain from 3-D human error sensitivity analysis by selecting finely classified segment. The results of sensitivity analysis show that the STI and AOT can be optimized provided human error probability is maintained within allowable range. (authors)

  4. On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

    Directory of Open Access Journals (Sweden)

    Jong-Bum Kim

    2016-10-01

    Full Text Available The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR has been developed and the validation and verification (V&V activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1, produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

  5. On the safety and performance demonstration tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and validation and verification of computational codes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jeong, Ji Young; Lee, Tae Ho; Kim, Sung Kyun; Euh, Dong Jin; Joo, Hyung Kook [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V and V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V and V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

  6. On the safety and performance demonstration tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and validation and verification of computational codes

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jeong, Ji Young; Lee, Tae Ho; Kim, Sung Kyun; Euh, Dong Jin; Joo, Hyung Kook

    2016-01-01

    The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V and V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V and V, and the performance test results of the model pump in sodium showed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results

  7. Analysis of developed transition road safety barrier systems.

    Science.gov (United States)

    Soltani, Mehrtash; Moghaddam, Taher Baghaee; Karim, Mohamed Rehan; Sulong, N H Ramli

    2013-10-01

    Road safety barriers protect vehicles from roadside hazards by redirecting errant vehicles in a safe manner as well as providing high levels of safety during and after impact. This paper focused on transition safety barrier systems which were located at the point of attachment between a bridge and roadside barriers. The aim of this study was to provide an overview of the behavior of transition systems located at upstream bridge rail with different designs and performance levels. Design factors such as occupant risk and vehicle trajectory for different systems were collected and compared. To achieve this aim a comprehensive database was developed using previous studies. The comparison showed that Test 3-21, which is conducted by impacting a pickup truck with speed of 100 km/h and angle of 25° to transition system, was the most severe test. Occupant impact velocity and ridedown acceleration for heavy vehicles were lower than the amounts for passenger cars and pickup trucks, and in most cases higher occupant lateral impact ridedown acceleration was observed on vehicles subjected to higher levels of damage. The best transition system was selected to give optimum performance which reduced occupant risk factors using the similar crashes in accordance with Test 3-21. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Testing the Copernican principle with future radio-astronomy observations

    OpenAIRE

    Bester, Hertzog L.; Larena, Julien; Bishop, Nigel T.

    2017-01-01

    We use a direct observational approach to investigate the possibility of testing the Copernican principle with data from upcoming radio surveys. In particular we illustrate the importance of measuring derivatives transverse to the past light-cone when prior knowledge of the value of the cosmological constant is not available.

  9. Safety climate and attitude as evaluation measures of organizational safety.

    Science.gov (United States)

    Isla Díaz, R; Díaz Cabrera, D

    1997-09-01

    The main aim of this research is to develop a set of evaluation measures for safety attitudes and safety climate. Specifically it is intended: (a) to test the instruments; (b) to identify the essential dimensions of the safety climate in the airport ground handling companies; (c) to assess the quality of the differences in the safety climate for each company and its relation to the accident rate; (d) to analyse the relationship between attitudes and safety climate; and (e) to evaluate the influences of situational and personal factors on both safety climate and attitude. The study sample consisted of 166 subjects from three airport companies. Specifically, this research was centered on ground handling departments. The factor analysis of the safety climate instrument resulted in six factors which explained 69.8% of the total variance. We found significant differences in safety attitudes and climate in relation to type of enterprise.

  10. LHI (low head safety injection) emergency cooling pump test for the EPR trademark in operation with solid matter loaded water

    International Nuclear Information System (INIS)

    Ganzmann, I.; Schulte, C.

    2010-01-01

    Emergency cooling pumps are essential and indispensable components of the NPP safety philosophy. In case of a loss-of coolant accident solid matter (debris: fibrous insulation material, concrete dust, pigment particles) might be released into the coolant, LHSI (low head safety injection) pumps have to ensure their performance capacity for a certain amount of debris without damage or loss of power. The authors describe the development of a test facility. The LHSI was tested in continuous operation over a time period of 14 days with a debris content of 1500 ppm (90% mineral wool fibers, 3% concrete dust, 3% pigment particles, 4% microporous insulation material). The pump did not show any damage or loss of hydraulic power. Further tests including thermoshock conditions (temperature changes of 160 C) are planned.

  11. First analysis of AGS0, LT2 and E9 CABRI tests with the new SFR safety code ASTEC-Na

    International Nuclear Information System (INIS)

    Perez-Martin, Sara; Bandini, Giacomino; Matuzas, Vaidas; Buck, Michael; Girault, Nathalie

    2015-01-01

    Within the framework of the European JASMIN project, the ASTEC-Na code is being developed for safety analysis of severe accidents in SFR. In the first phase of validation of the ASTEC-Na fuel thermo-mechanical models three in-pile tests conducted in the CABRI experimental reactor have been selected to be analysed. We present here the preliminary results of the simulation of two Transient Over Power tests and one power ramp test (AGS0, LT2 and E9, respectively) where no pin failure occurred during the transient. We present the comparison of ASTEC-Na results against experimental data and other safety code results for the initial steady state conditions prior to the transient onset as well as for the fuel pin behaviour during the transients. (author)

  12. Testing over-representation of observations in subsets of a DEA technology

    DEFF Research Database (Denmark)

    Asmild, Mette; Hougaard, Jens Leth; Olesen, Ole Bent

    2013-01-01

    This paper proposes a test for whether data are over-represented in a given production zone, i.e. a subset of a production possibility set which has been estimated using the non-parametric Data Envelopment Analysis (DEA) approach. A binomial test is used that relates the number of observations...

  13. Vicarious Desensitization of Test Anxiety Through Observation of Video-taped Treatment

    Science.gov (United States)

    Mann, Jay

    1972-01-01

    Procedural variations were compared for a vicarious group treatment of test anxiety involving observation of videotapes depicting systematic desensitization of a model. The theoretical implications of the present study and the feasibility of using videotaped materials to treat test anxiety and other avoidance responses in school settings are…

  14. New IAEA guidance on safety culture

    International Nuclear Information System (INIS)

    Haage, Monica; )

    2012-01-01

    Monica Haage described a project for Kozloduy Nuclear Power Plant in Bulgaria which was also funded by the Norwegian government. This project included the development of guidance documents and training on self-assessment and continuous improvement of safety culture. A draft IAEA safety culture survey was also developed as part of this project in collaboration with St Mary's University, Canada. This project was conducted in parallel with an IAEA project to develop new safety reports on safety culture self-assessment and continuous improvement. A safety report on safety culture during the pre-operational phases of NPPs has also been drafted. The IAEA approach to safety culture assessment was outlined and core principles of the approach were discussed. These include the use of several assessment methods (survey, interview, observation, focus groups, document review), and two distinct levels of analysis. The first is a descriptive analysis of the observed cultural characteristics from each assessment method and overarching themes. This is followed by a 'normative' analysis comparing what has been observed with the desirable characteristics of a strong, positive, safety culture, as defined by the IAEA safety culture framework. The application of this approach during recent Operational Safety Assessment Review Team (OSART) missions was described along with key learning points

  15. The Analysis of Loop Seal Purge Time for the KHNP Pressurizer Safety Valve Test Facility Using the GOTHIC Code

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Ae; Kim, Chang Hyun; Kweon, Gab Joo; Park, Jong Woon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2007-10-15

    The pressurizer safety valves (PSV) in Pressurized Water Reactors are required to provide the overpressure protection for the Reactor Coolant System (RCS) during the overpressure transients. Korea Hydro and Nuclear Power Company (KHNP) plans to build the PSV test facility for the purpose of providing the PSV pop-up characteristics and the loop seal dynamics for the new safety analysis. When the pressurizer safety valve is mounted in a loop seal configuration, the valve must initially pass the loop seal water prior to popping open on steam. The loop seal in the upstream of PSV prevents leakage of hydrogen gas or steam through the safety valve seat. This paper studies on the loop seal clearing dynamics using GOTHIC-7.2a code to verify the effects of loop seal purge time on the reactor coolant system overpressure.

  16. Disgruntled employees challenge GPU on TMI-2 polar crane safety, say load test needed

    International Nuclear Information System (INIS)

    Smock, R.

    1983-01-01

    Workers at the Three Mile Island No. 2 unit have gone public with their complaint that General Public Utilities (GPU) Corp. is ignoring safety at the cleanup site. With the exception of a specific concern over an overhead crane inside the containment building, however, the charges are vague. The polar crane will be used to lift the 170 to 180-ton reactor vessel head later this year, but a plant engineer faults the planned test procedure because it calls for lifting 40-ton missile shields from above the reactor before the crane is tested for strength. If the crane fails when lifting the missile shields, the engineer contends, there could be another loss of coolant. GPU rejected a 50-ton test of the crane because it is not required and because the risk is virtually zero. The utility also argues that additional testing will only increase exposure for the workers. 1 figure

  17. The Milieu Manager: A Nursing Staffing Strategy to Reduce Observer Use in the Acute Psychiatric Inpatient Setting.

    Science.gov (United States)

    Triplett, Patrick; Dearholt, Sandra; Cooper, Mary; Herzke, John; Johnson, Erin; Parks, Joyce; Sullivan, Patricia; Taylor, Karin F; Rohde, Judith

    Rising acuity levels in inpatient settings have led to growing reliance on observers and increased the cost of care. Minimizing use of observers, maintaining quality and safety of care, and improving bed access, without increasing cost. Nursing staff on two inpatient psychiatric units at an academic medical center pilot-tested the use of a "milieu manager" to address rising patient acuity and growing reliance on observers. Nursing cost, occupancy, discharge volume, unit closures, observer expense, and incremental nursing costs were tracked. Staff satisfaction and reported patient behavioral/safety events were assessed. The pilot initiatives ran for 8 months. Unit/bed closures fell to zero on both units. Occupancy, patient days, and discharges increased. Incremental nursing cost was offset by reduction in observer expense and by revenue from increases in occupancy and patient days. Staff work satisfaction improved and measures of patient safety were unchanged. The intervention was effective in reducing observation expense and improved occupancy and patient days while maintaining patient safety, representing a cost-effective and safe approach for management of acuity on inpatient psychiatric units.

  18. Large scale reflood test with cylindrical core test facility (CCTF). Core I. FY 1979 tests

    International Nuclear Information System (INIS)

    Murao, Yoshio; Akimoto, Hajime; Okubo, Tsutomu; Sudoh, Takashi; Hirano, Kenmei

    1982-03-01

    This report presents the results of analysis of the data obtained in the CCTF Core I test series (19 tests) in FY. 1979 as an interim report. The Analysis of the test results showed that: (1) The present safety evaluation model on the reflood phenomena during LOCA conservatively represents the phenomena observed in the tests except for the downcomer thermohydrodynamic behavior. (2) The downcomer liquid level rose slowly and it took long time for the water to reach a terminal level or the spill-over level. It was presume that such a results was due to an overly conservative selection of the ECC flow rate. This presumption will be checked against a future test result for an increased flow rate. The loop-seal-water filling test was unsuccessful due to a premature power shutdown by the core protection circuit. The test will be conducted again. The tests to be performed in the future are summerized. Tests for investigation of the refill phenomena were also proposed. (author)

  19. Structural safety of HDR reactor building during large scale vibration tests

    International Nuclear Information System (INIS)

    Stangenberg, F.; Zinn, R.

    1985-01-01

    In the second phase of the HDR investigations, a high shaker excitation of the building is planned using a large shaker which will be located on the operating floor and will be brought up to speed in a balanced condition and then unbalanced and decoupled from the drive system. With decreasing speed the shaker comes in resonance with the building frequencies and its energy is transferred to the building. In this paper the structural safety of the reactor building during the projected shaker tests is analysed. Dynamic response calculations with coupling between building and shaker by simultaneously integrating the equilibrium equations of both building and shaker are presented. The resulting building stresses, soil pressures etc. are compared with allowable values. (orig.)

  20. ENSI Approach to Oversight of Safety Culture

    International Nuclear Information System (INIS)

    Humbel Haag, Claudia

    2012-01-01

    Claudia Humbel Haag presented developments in ENSI approach to safety culture oversight. ENSI has developed a definition/understanding of Safety Culture and a concept of how to perform oversight of Safety Culture. ENSI defines safety culture in the following way: Safety Culture comprises the behaviour, world views (in the sense of conceptualisations of reality and explanation models), values (in the sense of aims and evaluation scales), and features of the physical environment (specifically, the nuclear power plant and the documents used) which are shared by many members of an organization, in as much as these are of significance to nuclear safety. A model of the accessibility of safety culture was presented ranging from the observable (external aspects of safety culture), to aspects that are accessible by asking questions, through to aspects that are not accessible (internal part of safety culture). ENSI considers observable aspects through the existing systematic safety assessment compliance program. Aspects that are observable by asking questions will be addressed by additional oversight activities outside the systematic assessment program. Aspects that are not accessible are addressed by helping the licensee to re-think its safety culture through proactive discussions on safety culture. Reports are issued to the licensee on assumptions and observations identified through the discussions. The conclusions of the presentation emphasised the importance of basing any interventions in this area on a solid understanding of the concept of safety culture. ENSI safety culture oversight principles were also described. These include licensee responsibility for safety, and the need for the regulator to critically review their own activities to ensure a positive influence on the licensee

  1. The safety of a novel early mobilization protocol conducted by ICU physicians: a prospective observational study

    Directory of Open Access Journals (Sweden)

    Keibun Liu

    2018-02-01

    Full Text Available Abstract Background There are numerous barriers to early mobilization (EM in a resource-limited intensive care unit (ICU without a specialized team or an EM culture, regarding patient stability while critically ill or in the presence of medical devices. We hypothesized that ICU physicians can overcome these barriers. The aim of this study was to investigate the safety of EM according to the Maebashi EM protocol conducted by ICU physicians. Methods This was a single-center prospective observational study. All consecutive patients with an unplanned emergency admission were included in this study, according to the exclusion criteria. The observation period was from June 2015 to June 2016. Data regarding adverse events, medical devices in place during rehabilitation, protocol adherence, and rehabilitation outcomes were collected. The primary outcome was safety. Results A total of 232 consecutively enrolled patients underwent 587 rehabilitation sessions. Thirteen adverse events occurred (2.2%; 95% confidence interval, 1.2–3.8% and no specific treatment was needed. There were no instances of dislodgement or obstruction of medical devices, tubes, or lines. The incidence of adverse events associated with mechanical ventilation or extracorporeal membrane oxygenation (ECMO was 2.4 and 3.6%, respectively. Of 587 sessions, 387 (66% sessions were performed at the active rehabilitation level, including sitting out of the bed, active transfer to a chair, standing, marching, and ambulating. ICU physicians attended over 95% of these active rehabilitation sessions. Of all patients, 143 (62% got out of bed within 2 days (median 1.2 days; interquartile range 0.1–2.0. Conclusions EM according to the Maebashi EM protocol conducted by ICU physicians, without a specialized team or EM culture, was performed at a level of safety similar to previous studies performed by specialized teams, even with medical devices in place, including mechanical ventilation or ECMO

  2. Digital System Reliability Test for the Evaluation of safety Critical Software of Digital Reactor Protection System

    Directory of Open Access Journals (Sweden)

    Hyun-Kook Shin

    2006-08-01

    Full Text Available A new Digital Reactor Protection System (DRPS based on VME bus Single Board Computer has been developed by KOPEC to prevent software Common Mode Failure(CMF inside digital system. The new DRPS has been proved to be an effective digital safety system to prevent CMF by Defense-in-Depth and Diversity (DID&D analysis. However, for practical use in Nuclear Power Plants, the performance test and the reliability test are essential for the digital system qualification. In this study, a single channel of DRPS prototype has been manufactured for the evaluation of DRPS capabilities. The integrated functional tests are performed and the system reliability is analyzed and tested. The results of reliability test show that the application software of DRPS has a very high reliability compared with the analog reactor protection systems.

  3. Safety Testing of AGR-2 UCO Compacts 6-4-2 and 2-3-1

    Energy Technology Data Exchange (ETDEWEB)

    Hunn, John D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Morris, Robert N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baldwin, Charles A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Burns, Zachary M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Montgomery, Fred C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Skitt, Darren J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    Post-irradiation examination (PIE) and elevated-temperature safety testing are being performed on tristructural-isotropic (TRISO) coated-particle fuel compacts from the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program second irradiation experiment (AGR-2). Details on this irradiation experiment have been previously reported [Collin 2014]. The AGR-2 PIE effort builds upon the understanding acquired throughout the AGR-1 PIE campaign [Demkowicz et al. 2015] and is establishing a database for the different AGR-2 fuel designs.

  4. Safety requirements, facility user needs, and reactor concepts for a new Broad Application Test Reactor

    International Nuclear Information System (INIS)

    Ryskamp, J.M.; Liebenthal, J.L.; Denison, A.B.; Fletcher, C.D.

    1992-07-01

    This report describes the EG ampersand G Laboratory Directed Research and Development Program (LDRD) Broad Application Test Reactor (BATR) Project that was conducted in fiscal year 1991. The scope of this project was divided into three phases: a project process definition phase, a requirements development phase, and a preconceptual reactor design and evaluation phase. Multidisciplinary teams of experts conducted each phase. This report presents the need for a new test reactor, the project process definition, a set of current and projected regulatory compliance and safety requirements, a set of facility user needs for a broad range of projected testing missions, and descriptions of reactor concepts capable of meeting these requirements. This information can be applied to strategic planning to provide the Department of Energy with management options

  5. Probabilistic methods of optimization of scheduled tests for heat equipment of safety systems of reactor at full power

    International Nuclear Information System (INIS)

    Bilej, D.V.; Fridman, N.A.; Kolykhanov, V.N.; Skalozubov, V.I.

    2004-01-01

    This article generalises the basic results of a long-term teamwork with respect to a scientific and technical substantiation of perfection of the regulations of safe operation power units with VVER. This perfection is concerning a periodicity and volumes of tests of safety systems when a reactor works at full power. The article shows that the application of the probabilistic approaches connected to minimisation of a risk criterion function is an effective methodical base for the optimisation. For certain safety systems of serial power units with VVER 1000 the results of calculated substantiations are presented

  6. 78 FR 54510 - New Entrant Safety Assurance Program Operational Test

    Science.gov (United States)

    2013-09-04

    ... safety management controls; (2) consider their effects on small businesses; and (3) consider establishing alternate locations where such reviews may be conducted for the convenience of small businesses. In response... safety review within 18 months of starting interstate operations. [49 U.S.C. 31144(g)]. In issuing these...

  7. Safety demonstration tests on pressure rise in ventilation system and blower integrity of a fuel-reprocessing plant

    Energy Technology Data Exchange (ETDEWEB)

    Takada, Junichi; Suzuki, Motoe; Tsukamoto, Michio; Koike, Tadao; Nishio, Gunji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-12-01

    In JAERI, the demonstration test was carried out as a part of safety researches of the fuel-reprocessing plant using a large-scale facility consist of cells, ducts, dumpers, HEPA filters and a blower, when an explosive burning due to a rapid reaction of thermal decomposition for solvent/nitric acid occurs in a cell of the reprocessing plant. In the demonstration test, pressure response propagating through the facility was measured under a blowing of air from a pressurized tank into the cell in the facility to elucidate an influence of pressure rise in the ventilation system. Consequently, effective pressure decrease in the facility was given by a configuration of cells and ducts in the facility. In the test, transient responses of HEPA filters and the blower by the blowing of air were also measured to confirm the integrity. So that, it is confirmed that HEPA filters and the blower under pressure loading were sufficient to maintain the integrity. The content described in this report will contribute to safety assessment of the ventilation system in the event of explosive burning in the reprocessing plant. (author)

  8. Fast reactor test facilities in the US safety program

    International Nuclear Information System (INIS)

    Avery, R.; Dickerman, C.E.; Lennox, D.H.; Rose, D.

    1979-01-01

    The needs for safety information derivable from in-pile programs are reviewed, and the correlation made with existing and planned capability. In view of the current status of the U.S. breeder program, emphasis is given in the review to the impact of different fast breeder options on the required program and facilities. It is concluded that facility needs are somewhat independent of specific fast breeder concept, even though the relative emphasis on the various safety issues will differ. 8 refs

  9. Performance of multihundred-watt fueled-sphere assemblies in the safety verification test

    International Nuclear Information System (INIS)

    Cramer, E.M.

    1975-09-01

    Seven fueled-sphere assemblies equivalent to those proposed for use in multihundred-watt thermoelectric generators were subjected to conditions that simulated the sequential environments produced by an orbital abort and earth impact. The procedures were similar to those in the Safety Sequential Test, and the assemblies differed only in minor dimensional and power level changes. All assemblies met the specifications for flight quality units. Visual examination indicated that all the iridium shells had lost their containment capability; however, rupturing of two shells was not confirmed. Five were obviously ruptured, and the fuel in three was exposed. All iridium fractures were essentially intergranular. A large grain size may have promoted this type of failure. Half of the vent assemblies failed to pass helium at ambient temperature after the test. Failure was because of nonmetallic materials in the vent frits. Release of plutonia per unit area of cracks in a containment shell ruptured by simulated earth impact was determined

  10. Effects of rest time after Li plating on safety behavior—ARC tests with commercial high-energy 18650 Li-ion cells

    International Nuclear Information System (INIS)

    Waldmann, Thomas; Wohlfahrt-Mehrens, Margret

    2017-01-01

    During charging at low temperatures, metallic Lithium can be deposited on the surface of graphite anodes of Li-ion cells. This Li plating does not only lead to fast capacity fade, it can also impair the safety behavior. The present study observes the effect of rest periods between Li plating and subsequent accelerated rate calorimetry (ARC) tests. As an example, commercial 3.25 Ah 18650-type cells with graphite anodes and NCA cathodes are cycled at 0 °C to provoke Li plating. It is found that the rest period at 25 °C between Li plating and the ARC tests has a significant influence on the onset temperature of exothermic reactions (T SH ), the onset temperature of thermal runaway (T TR ), the maximum temperature, the self-heating rate, and on damage patterns of 18650 cells. The results are discussed in terms of chemical intercalation of Li plating into adjacent graphite particles during the rest period. The exponential increase of capacity recovery and T SH as a function of time suggests a reaction of 1st order for the relaxation process.

  11. Modelling blood safety

    NARCIS (Netherlands)

    Janssen, M.P.

    2010-01-01

    This thesis describes the development and application of methods and models to support decision making on safety measures aimed at preventing the transmission of infections by blood donors. Safety measures refer to screening tests for blood donors, quarantine periods for blood plasma, or methods for

  12. Use of FPGA and CPLD in nuclear reactor safety systems and its regulatory review requirements for reactor safety

    International Nuclear Information System (INIS)

    Roy, Suvadip; Biswas, Animesh; Pradhan, S.K.

    2015-01-01

    Field Programmable Gate Arrays (FPGA) and Complex Programmable Logic Devices (CPLD) is being used widely in safety critical and safety related systems in nuclear power plans like in trip logic units, Engineered Safety Feature (ESF) actuation decision logic and neutronic signal processing for their reprogrammability feature and compact design. These HDL Programmable devices (HPD) are complex devices consisting of both hardware and software which is used to implement the logic on the FPGA. It is observed that these Programmable devices suffer from various modes of failure and the major failures in these devices are due to Single Event Upset (SEU), where a highly energetic ionizing radiation may lead to device failure which can even occur in radiologically benign environment. Other failures can occur during steps of developing the hardware using software tools like during Synthesis and placement and routing of the desired hardware. Here a study on use of such devices in Nuclear Reactors, study on mode of failures of these devices, way to tackle such failure and development of review guidelines for review of such devices used in safety critical and safety related systems with special emphasis on choice of software tools, way to mitigate effects of SEU and simulation and hardware testing results to be reviewed by regulatory body during design safety review is done. (author)

  13. Environmental safety analysis tests on the Light Weight Radioisotope Heater Unit (LWRHU)

    International Nuclear Information System (INIS)

    Tate, R.E.; Land, C.C.

    1985-05-01

    A series of safety tests has been performed on the Light Weight Radioisotope Heater Unit (LWRHU), a 238 PuO 2 -fueled device designed to provide thermal energy at selected locations in a spacecraft. The tests simulate the thermal and mechanical environments postulated for spacecraft accidents on the launch pad and on reentry abort. The tests demonstrate almost complete containment of the fuel, or fuel simulant (depleted UO 2 ), in (1) an overpressure environment of 12.76 MPa (1850 psi), (2) on impact by an 18-g aluminum fuel-tank fragment at velocities greater than 750 m/s (2460 ft/s) but less than 900 m/s (2950 ft/s), (3) during a 10.5-min burn of a 0.9 x 0.9 x 0.9 m (3 x 3 x 3 ft) block of solid rocket motor propellant, (4) after impact at 49 m/s (161 ft/s) in four different orientations on a hard surface, and (5) during immersion in seawater for 1.75 years at both sea level pressure and at a pressure equivalent to 6000 m (19,700 ft) of ocean depth

  14. The safety and effectiveness profile of eldecalcitol in a prospective, post-marketing observational study in Japanese male patients with osteoporosis.

    Science.gov (United States)

    Kondo, Satoshi; Kakihata, Hiroyuki; Nishida, Yosuke; Furuno, Yuko; Kobayashi, Yumiko; Tabata, Hidehiro; Nomura, Makoto

    2018-03-12

    We conducted a post-marketing observational study to investigate the safety and effectiveness of eldecalcitol for the treatment of osteoporosis in a Japanese clinical setting. The observation period was 12 months for women and 36 months for men. The final results for the female patients have already been published. In this article, the final results for the male patients are reported. A total of 470 male osteoporosis patients were enrolled. The safety analysis set included 431 patients (mean age, 76.8 years; mean ± SD follow-up period, 631.0 ± 450.3 days), and 175 patients continued treatment throughout the 3-year observational period. Adverse drug reactions (ADRs) were reported in 28 patients (6.49%); the most common ADRs were hypercalcemia (1.16%) and renal impairment (1.16%). Serious ADRs were reported in 5 patients (1.16%). Mean serum calcium was within the normal range throughout the observation period. The cumulative incidence of new vertebral and nonvertebral fractures at 36 months, estimated by Kaplan-Meier analysis, was 10.23 and 4.06%, respectively. At the last observation, mean lumbar spine bone mineral density was 3.49% higher (P effectiveness of eldecalcitol for the treatment of Japanese male osteoporosis patients was confirmed in clinical practice. Careful monitoring of serum calcium and estimated glomerular filtration rate, both before and during treatment, is necessary to minimize the risk of hypercalcemia and renal impairment while maximizing the effectiveness of eldecalcitol.

  15. Safety Culture Monitoring: How to Assess Safety Culture in Real Time?

    International Nuclear Information System (INIS)

    Zronek, B.; Maryska, J.; Treslova, L.

    2016-01-01

    Do you know what is current level of safety culture in your company? Are you able to follow trend changes? Do you know what your recent issues are? Since safety culture is understood as vital part of nuclear industry daily life, it is crucial to know what the current level is. It is common to perform safety culture survey or ad hoc assessment. This contribution shares Temelin NPP, CEZ approach how to assess safety culture level permanently. Using behavioral related outputs of gap solving system, observation program, dedicated surveys, regulatory assessment, etc., allows creating real time safety culture monitoring without the need to perform any other activities. (author)

  16. Block 4 and Cluster D - Safety

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    After transfer of Bloc4 test facility to SM18 its safety system was upgraded in 2014/2015 for its 3 existing test cryostats. In 2016 a new test facility HFM (High Field Magnet) was integrated in the Bloc4. A new test facility Cluster D which is similar to HFM is in a process of installation in SM18. The Presentation is dedicated to safety strategy of Bloc4 and Cluster D and focused on an analysis of risk conditions and on the real behaviour of safety valves in case of discharge. Protection of sub-atmospheric circuits is also discussed.

  17. Integrated assessment of pedestrian head impact protection in testing secondary safety and autonomous emergency braking.

    Science.gov (United States)

    Searson, D J; Anderson, R W G; Hutchinson, T P

    2014-02-01

    Pedestrian impact testing is used to provide information to the public about the relative level of protection provided by different vehicles to a struck pedestrian. Autonomous Emergency Braking (AEB) is a relatively new technology that aims to reduce the impact speed of such crashes. It is expected that vehicles with AEB will pose less harm to pedestrians, and that the benefit will come about through reductions in the number of collisions and a change in the severity of impacts that will still occur. In this paper, an integration of the assessment of AEB performance and impact performance is proposed based on average injury risk. Average injury risk is calculated using the result of an impact test and a previously published distribution of real world crash speeds. A second published speed distribution is used that accounts for the effects of AEB, and reduced average risks are implied. This principle allows the effects of AEB systems and secondary safety performance to be integrated into a single measure of safety. The results are used to examine the effect of AEB on Euro NCAP and ANCAP assessments using previously published results on the likely effect of AEB. The results show that, given certain assumptions about AEB performance, the addition of AEB is approximately the equivalent of increasing Euro NCAP test performance by one band, which corresponds to an increase in the score of 25% of the maximum. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Safety demonstration tests on thermal decomposition of nitrated solvent with nitric acid in nuclear fuel reprocessing plants. Contract research

    International Nuclear Information System (INIS)

    Tsukamoto, Michio; Takada, Junichi; Koike, Tadao; Watanabe, Koji; Uchiyama, Gunzou; Nishio, Gunji; Murata, Mikio

    2001-03-01

    The demonstration tests were conducted to investigate the safety of the ventilation system and integrity of the HEPA filters under the design basis accident (DBA) of the evaporator in the reprocessing plants. The tests were carried out by heating organic solvent (TBP/n- dodecane) mixed with nitric acid in a sealed vessel. It was possible to cause an explosive decomposition of TBP-complex formed by nitration of the solvent with nitric acid. The following was obtained by the analysis of the experimental results of the tests. From derivation by the experimental method, data on the maximum mass release rate and the maximum energy release rate in the explosion, as the solvent of 1 [kg] spouted out by the thermal decomposition, were obtained. They were 0.59 [kg/s] and 3240.3 [kJ/kg·s] respectively. The influence given on the cell ventilation system by this explosion was small and it was demonstrated that the safety of the HEPA filters could be secured. (author)

  19. Seismic safety margin assessment program (Annual safety research report, JFY 2010)

    International Nuclear Information System (INIS)

    Suzuki, Kenichi; Iijima, Toru; Inagaki, Masakatsu; Taoka, Hideto; Hidaka, Shinjiro

    2011-01-01

    Seismic capacity test data, analysis method and evaluation code provided by Seismic Safety Margin Assessment Program have been utilized for the support of seismic back-check evaluation of existing plants. The summary of the program in 2010 is as follows. 1. Component seismic capacity test and quantitative seismic capacity evaluation. Many seismic capacity tests of various snubbers were conducted and quantitative seismic capacities were evaluated. One of the emergency diesel generator partial-model seismic capacity tests was conducted and quantitative seismic capacity was evaluated. Some of the analytical evaluations of piping-system seismic capacities were conducted. 2. Analysis method for minute evaluation of component seismic response. The difference of seismic response of large components such as primary containment vessel and reactor pressure vessel when they were coupled with 3-dimensional FEM building model or 1-dimensional lumped mass building model, was quantitatively evaluated. 3. Evaluation code for quantitative evaluation of seismic safety margin of systems, structures and components. As the example, quantitative evaluation of seismic safety margin of systems, structures and components were conducted for the reference plant. (author)

  20. Test and evaluation on safety relating to biotechnology; Biotechnology ni kansuru anzensei no shiken to hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Okada, M. [Bio-Oriented Technology Research Advancement Inst., Saitama (Japan)

    1996-09-05

    This paper describes the current status and how works are being carried out on safety tests and evaluation of gene recombinants in plants and microorganisms. In the field of plants, Flavr Savr tomato which has been improved in fully ripe fruit distribution and keeping quality was commercialized as the world`s first recombinant food in May 1994 by Calgene, Inc. of America. Other vegetables, such as soybean, corn, potato, and pumpkin have been completed of all items of safety evaluation, and are approaching the commercialization phase. The safety evaluation system for living organisms created by using recombinant DNA technologies has been established internationally with regard to its general framework and contents based on accumulated knowledeges and experiences as a result of utilization of over twenty years. Industrial utilization guidelines for recombinants in Japan have been established in correspondence with the OECD recommendation in 1986. Experiments to verify recombinants to be safe in environment, and cultivation of the recombinants for utilization are performed based on the experimental guidelines and utilization guidelines. 15 refs., 1 fig., 5 tabs.